Effects of Classroom Ventilation Rate and Temperature on Students' Test Scores.
Haverinen-Shaughnessy, Ulla; Shaughnessy, Richard J
2015-01-01
Using a multilevel approach, we estimated the effects of classroom ventilation rate and temperature on academic achievement. The analysis is based on measurement data from a 70 elementary school district (140 fifth grade classrooms) from Southwestern United States, and student level data (N = 3109) on socioeconomic variables and standardized test scores. There was a statistically significant association between ventilation rates and mathematics scores, and it was stronger when the six classrooms with high ventilation rates that were indicated as outliers were filtered (> 7.1 l/s per person). The association remained significant when prior year test scores were included in the model, resulting in less unexplained variability. Students' mean mathematics scores (average 2286 points) were increased by up to eleven points (0.5%) per each liter per second per person increase in ventilation rate within the range of 0.9-7.1 l/s per person (estimated effect size 74 points). There was an additional increase of 12-13 points per each 1°C decrease in temperature within the observed range of 20-25°C (estimated effect size 67 points). Effects of similar magnitude but higher variability were observed for reading and science scores. In conclusion, maintaining adequate ventilation and thermal comfort in classrooms could significantly improve academic achievement of students.
Effects of Classroom Ventilation Rate and Temperature on Students’ Test Scores
2015-01-01
Using a multilevel approach, we estimated the effects of classroom ventilation rate and temperature on academic achievement. The analysis is based on measurement data from a 70 elementary school district (140 fifth grade classrooms) from Southwestern United States, and student level data (N = 3109) on socioeconomic variables and standardized test scores. There was a statistically significant association between ventilation rates and mathematics scores, and it was stronger when the six classrooms with high ventilation rates that were indicated as outliers were filtered (> 7.1 l/s per person). The association remained significant when prior year test scores were included in the model, resulting in less unexplained variability. Students’ mean mathematics scores (average 2286 points) were increased by up to eleven points (0.5%) per each liter per second per person increase in ventilation rate within the range of 0.9–7.1 l/s per person (estimated effect size 74 points). There was an additional increase of 12–13 points per each 1°C decrease in temperature within the observed range of 20–25°C (estimated effect size 67 points). Effects of similar magnitude but higher variability were observed for reading and science scores. In conclusion, maintaining adequate ventilation and thermal comfort in classrooms could significantly improve academic achievement of students. PMID:26317643
Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days.
Thomachot, Laurent; Leone, Marc; Razzouk, Karim; Antonini, François; Vialet, Renaud; Martin, Claude
2002-01-01
To determine whether extended use (7 days) would affect the efficiency on heat and water preservation of a hydrophobic condenser humidifier as well as the rate of ventilation-acquired pneumonia, compared with 1 day of use. Prospective, controlled, randomized, not blinded, clinical study. Twelve-bed intensive care unit of a university hospital. One hundred and fifty-five consecutive patients undergoing mechanical ventilation for > or = 48 hrs. After randomization, patients were allocated to one of the two following groups: a) heat and moisture exchangers (HMEs) changed every 24 hrs; b) HMEs changed only once a week. Devices in both groups could be changed at the discretion of the staff when signs of occlusion or increased resistance were identified. Efficient airway humidification and heating were assessed by clinical variables (numbers of tracheal suctionings and instillations required, peak and mean airway pressures). The frequency rates of bronchial colonization and ventilation-acquired pneumonia were evaluated by using clinical and microbiological criteria. Endotracheal tube occlusion, ventilatory support variables, duration of mechanical ventilation, length of intensive care, acquired multiorgan dysfunction, and mortality rates also were recorded. The two groups were similar at the time of randomization. Endotracheal tube occlusion never occurred. In the targeted population (patients ventilated for > or = 7 days), the frequency rate of ventilation-acquired pneumonia was 24% in the HME 1-day group and 17% in the HME 7-day group (p > .05, not significant). Ventilation-acquired pneumonia rates per 1000 ventilatory support days were 16.4/1000 in the HME 1-day group and 12.4/1000 in the HME 7-day group (p > .05, not significant). No statistically significant differences were found between the two groups for duration of mechanical ventilation, intensive care unit length of stay, acquired organ system derangements, and mortality rate. There was indirect evidence of very little, if any, change in HME resistance. Changing the studied hydrophobic HME after 7 days did not affect efficiency, increase resistance, or altered bacterial colonization. The frequency rate of ventilation-acquired pneumonia was also unchanged. Use of HMEs for > 24 hrs and up to 7 days is safe.
Cheong, Chang Heon; Lee, Seonhye
2018-01-01
The prevention of airborne infections in emergency departments is a very important issue. This study investigated the effects of architectural features on airborne pathogen dispersion in emergency departments by using a CFD (computational fluid dynamics) simulation tool. The study included three architectural features as the major variables: increased ventilation rate, inlet and outlet diffuser positions, and partitions between beds. The most effective method for preventing pathogen dispersion and reducing the pathogen concentration was found to be increasing the ventilation rate. Installing partitions between the beds and changing the ventilation system’s inlet and outlet diffuser positions contributed only minimally to reducing the concentration of airborne pathogens. PMID:29534043
Cheong, Chang Heon; Lee, Seonhye
2018-03-13
The prevention of airborne infections in emergency departments is a very important issue. This study investigated the effects of architectural features on airborne pathogen dispersion in emergency departments by using a CFD (computational fluid dynamics) simulation tool. The study included three architectural features as the major variables: increased ventilation rate, inlet and outlet diffuser positions, and partitions between beds. The most effective method for preventing pathogen dispersion and reducing the pathogen concentration was found to be increasing the ventilation rate. Installing partitions between the beds and changing the ventilation system's inlet and outlet diffuser positions contributed only minimally to reducing the concentration of airborne pathogens.
Variable mechanical ventilation
Fontela, Paula Caitano; Prestes, Renata Bernardy; Forgiarini Jr., Luiz Alberto; Friedman, Gilberto
2017-01-01
Objective To review the literature on the use of variable mechanical ventilation and the main outcomes of this technique. Methods Search, selection, and analysis of all original articles on variable ventilation, without restriction on the period of publication and language, available in the electronic databases LILACS, MEDLINE®, and PubMed, by searching the terms "variable ventilation" OR "noisy ventilation" OR "biologically variable ventilation". Results A total of 36 studies were selected. Of these, 24 were original studies, including 21 experimental studies and three clinical studies. Conclusion Several experimental studies reported the beneficial effects of distinct variable ventilation strategies on lung function using different models of lung injury and healthy lungs. Variable ventilation seems to be a viable strategy for improving gas exchange and respiratory mechanics and preventing lung injury associated with mechanical ventilation. However, further clinical studies are necessary to assess the potential of variable ventilation strategies for the clinical improvement of patients undergoing mechanical ventilation. PMID:28444076
Souza-Oliveira, Ana Carolina; Cunha, Thúlio Marquez; Passos, Liliane Barbosa da Silva; Lopes, Gustavo Camargo; Gomes, Fabiola Alves; Röder, Denise Von Dolinger de Brito
2016-01-01
Ventilator-associated pneumonia is the most prevalent nosocomial infection in intensive care units and is associated with high mortality rates (14-70%). This study evaluated factors influencing mortality of patients with Ventilator-associated pneumonia (VAP), including bacterial resistance, prescription errors, and de-escalation of antibiotic therapy. This retrospective study included 120 cases of Ventilator-associated pneumonia admitted to the adult adult intensive care unit of the Federal University of Uberlândia. The chi-square test was used to compare qualitative variables. Student's t-test was used for quantitative variables and multiple logistic regression analysis to identify independent predictors of mortality. De-escalation of antibiotic therapy and resistant bacteria did not influence mortality. Mortality was 4 times and 3 times higher, respectively, in patients who received an inappropriate antibiotic loading dose and in patients whose antibiotic dose was not adjusted for renal function. Multiple logistic regression analysis revealed the incorrect adjustment for renal function was the only independent factor associated with increased mortality. Prescription errors influenced mortality of patients with Ventilator-associated pneumonia, underscoring the challenge of proper Ventilator-associated pneumonia treatment, which requires continuous reevaluation to ensure that clinical response to therapy meets expectations. Copyright © 2016. Published by Elsevier Editora Ltda.
Khemani, Robinder G; Sward, Katherine; Morris, Alan; Dean, J Michael; Newth, Christopher J L
2011-11-01
Although pediatric intensivists claim to embrace lung protective ventilation for acute lung injury (ALI), ventilator management is variable. We describe ventilator changes clinicians made for children with hypoxemic respiratory failure, and evaluate the potential acceptability of a pediatric ventilation protocol. This was a retrospective cohort study performed in a tertiary care pediatric intensive care unit (PICU). The study period was from January 2000 to July 2007. We included mechanically ventilated children with PaO(2)/FiO(2) (P/F) ratio less than 300. We assessed variability in ventilator management by evaluating actual changes to ventilator settings after an arterial blood gas (ABG). We evaluated the potential acceptability of a pediatric mechanical ventilation protocol we adapted from National Institutes of Health/National Heart, Lung, and Blood Institute (NIH/NHLBI) Acute Respiratory Distress Syndrome (ARDS) Network protocols by comparing actual practice changes in ventilator settings to changes that would have been recommended by the protocol. A total of 2,719 ABGs from 402 patients were associated with 6,017 ventilator settings. Clinicians infrequently decreased FiO(2), even when the PaO(2) was high (>68 mmHg). The protocol would have recommended more positive end expiratory pressure (PEEP) than was used in actual practice 42% of the time in the mid PaO(2) range (55-68 mmHg) and 67% of the time in the low PaO(2) range (<55 mmHg). Clinicians often made no change to either peak inspiratory pressure (PIP) or ventilator rate (VR) when the protocol would have recommended a change, even when the pH was greater than 7.45 with PIP at least 35 cmH(2)O. There may be lost opportunities to minimize potentially injurious ventilator settings for children with ALI. A reproducible pediatric mechanical ventilation protocol could prompt clinicians to make ventilator changes that are consistent with lung protective ventilation.
Sensor-based demand controlled ventilation
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Almeida, A.T.; Fisk, W.J.
In most buildings, occupancy and indoor pollutant emission rates vary with time. With sensor-based demand-controlled ventilation (SBDCV), the rate of ventilation (i.e., rate of outside air supply) also varies with time to compensate for the changes in pollutant generation. In other words, SBDCV involves the application of sensing, feedback and control to modulate ventilation. Compared to ventilation without feedback, SBDCV offers two potential advantages: (1) better control of indoor pollutant concentrations; and (2) lower energy use and peak energy demand. SBDCV has the potential to improve indoor air quality by increasing the rate of ventilation when indoor pollutant generation ratesmore » are high and occupants are present. SBDCV can also save energy by decreasing the rate of ventilation when indoor pollutant generation rates are low or occupants are absent. After providing background information on indoor air quality and ventilation, this report provides a relatively comprehensive discussion of SBDCV. Topics covered in the report include basic principles of SBDCV, sensor technologies, technologies for controlling air flow rates, case studies of SBDCV, application of SBDCV to laboratory buildings, and research needs. SBDCV appears to be an increasingly attractive technology option. Based on the review of literature and theoretical considerations, the application of SBDCV has the potential to be cost-effective in applications with the following characteristics: (a) a single or small number of dominant pollutants, so that ventilation sufficient to control the concentration of the dominant pollutants provides effective control of all other pollutants; (b) large buildings or rooms with unpredictable temporally variable occupancy or pollutant emission; and (c) climates with high heating or cooling loads or locations with expensive energy.« less
Proportional mechanical ventilation through PWM driven on/off solenoid valve.
Sardellitti, I; Cecchini, S; Silvestri, S; Caldwell, D G
2010-01-01
Proportional strategies for artificial ventilation are the most recent form of synchronized partial ventilatory assistance and intra-breath control techniques available in clinical practice. Currently, the majority of commercial ventilators allowing proportional ventilation uses proportional valves to generate the flow rate pattern. This paper proposes on-off solenoid valves for proportional ventilation given their small size, low cost and short switching time, useful for supplying high frequency ventilation. A new system based on a novel fast switching driver circuit combined with on/off solenoid valve is developed. The average short response time typical of onoff solenoid valves was further reduced through the driving circuit for the implementation of PWM control. Experimental trials were conducted for identifying the dynamic response of the PWM driven on/off valve and for verifying its effectiveness in generating variable-shaped ventilatory flow rate patterns. The system was able to smoothly follow the reference flow rate patterns also changing in time intervals as short as 20 ms, achieving a flow rate resolution up to 1 L/min and repeatability in the order of 0.5 L/min. Preliminary results showed the feasibility of developing a stand alone portable device able to generate both proportional and high frequency ventilation by only using on-off solenoid valves.
Martín-González, F; González-Robledo, J; Sánchez-Hernández, F; Moreno-García, M N; Barreda-Mellado, I
2016-01-01
To assess the effectiveness and identify predictors of failure of noninvasive ventilation. A retrospective, longitudinal descriptive study was made. Adult patients with acute respiratory failure. A total of 410 consecutive patients with noninvasive ventilation treated in an Intensive Care Unit of a tertiary university hospital from 2006 to 2011. Noninvasive ventilation. Demographic variables and clinical and laboratory test parameters at the start and two hours after the start of noninvasive ventilation. Evolution during admission to the Unit and until hospital discharge. The failure rate was 50%, with an overall mortality rate of 33%. A total of 156 patients had hypoxemic respiratory failure, 87 postextubation respiratory failure, 78 exacerbation of chronic obstructive pulmonary disease, 61 hypercapnic respiratory failure without chronic obstructive pulmonary disease, and 28 had acute pulmonary edema. The failure rates were 74%, 54%, 27%, 31% and 21%, respectively. The etiology of respiratory failure, serum bilirubin at the start, APACHEII score, radiological findings, the need for sedation to tolerate noninvasive ventilation, changes in level of consciousness, PaO2/FIO2 ratio, respiratory rate and heart rate from the start and two hours after the start of noninvasive ventilation were independently associated to failure. The effectiveness of noninvasive ventilation varies according to the etiology of respiratory failure. Its use in hypoxemic respiratory failure and postextubation respiratory failure should be assessed individually. Predictors of failure could be useful to prevent delayed intubation. Copyright © 2015 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.
Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings.
MacNaughton, Piers; Pegues, James; Satish, Usha; Santanam, Suresh; Spengler, John; Allen, Joseph
2015-11-18
Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption-Economic and environmental costs. We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person), 30% enhanced ventilation, and 40 cfm/person) and four different heating, ventilation and air conditioning (HVAC) system strategies (Variable Air Volume (VAV) with reheat and a Fan Coil Unit (FCU), both with and without an energy recovery ventilator). We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities). The same change in ventilation improved the performance of workers by 8%, equivalent to a $6500 increase in employee productivity each year. Reduced absenteeism and improved health are also seen with enhanced ventilation. The health benefits associated with enhanced ventilation rates far exceed the per-person energy costs relative to salary costs. Environmental impacts can be mitigated at regional, building, and individual-level scales through the transition to renewable energy sources, adoption of energy efficient systems and ventilation strategies, and promotion of other sustainable policies.
Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings
MacNaughton, Piers; Pegues, James; Satish, Usha; Santanam, Suresh; Spengler, John; Allen, Joseph
2015-01-01
Introduction: Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption—Economic and environmental costs. Methods: We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person), 30% enhanced ventilation, and 40 cfm/person) and four different heating, ventilation and air conditioning (HVAC) system strategies (Variable Air Volume (VAV) with reheat and a Fan Coil Unit (FCU), both with and without an energy recovery ventilator). We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Results: Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities). The same change in ventilation improved the performance of workers by 8%, equivalent to a $6500 increase in employee productivity each year. Reduced absenteeism and improved health are also seen with enhanced ventilation. Conclusions: The health benefits associated with enhanced ventilation rates far exceed the per-person energy costs relative to salary costs. Environmental impacts can be mitigated at regional, building, and individual-level scales through the transition to renewable energy sources, adoption of energy efficient systems and ventilation strategies, and promotion of other sustainable policies. PMID:26593933
CFD Simulations to Improve Ventilation in Low-Income Housing
NASA Astrophysics Data System (ADS)
Ho, Rosemond; Gorle, Catherine
2017-11-01
Quality of housing plays an important role in public health. In Dhaka, Bangladesh, the leading causes of death include tuberculosis, lower respiratory infections, and chronic obstructive pulmonary disease, so improving home ventilation could potentially mitigate these negative health effects. The goal of this project is to use computational fluid dynamics (CFD) to predict the relative effectiveness of different ventilation strategies for Dhaka homes. A Reynolds-averaged Navier-Stokes CFD model of a standard Dhaka home with apertures of different sizes and locations was developed to predict air exchange rates. Our initial focus is on simulating ventilation driven by buoyancy-alone conditions, which is often considered the limiting case in natural ventilation design. We explore the relationship between ventilation rate and aperture area to determine the most promising configurations for optimal ventilation solutions. Future research will include the modeling of wind-driven conditions, and extensive uncertainty quantification studies to investigate the effect of variability in the layout of homes and neighborhoods, and in local wind and temperature conditions. The ultimate objective is to formulate robust design recommendations that can reduce risks of respiratory illness in low-income housing.
El-Saed, Aiman; Al-Jardani, Amina; Althaqafi, Abdulhakeem; Alansari, Huda; Alsalman, Jameela; Al Maskari, Zaina; El Gammal, Ayman; Al Nasser, Wafa; Al-Abri, Seif S; Balkhy, Hanan H
2016-07-01
Data estimating the rates of ventilator-associated pneumonia (VAP) in critical patients in Gulf Cooperation Council (GCC) countries are very limited. The aim of this study was to estimate VAP rates in GCC hospitals and to compare rates with published reports of the U.S. National Healthcare Safety Network (NHSN) and International Nosocomial Infection Control Consortium (INICC). VAP rates and ventilator utilization between 2008 and 2013 were calculated from aggregate VAP surveillance data using NHSN methodology pooled from 6 hospitals in 3 GCC countries: Saudi Arabia, Oman, and Bahrain. The standardized infection ratios of VAP in GCC hospitals were compared with published reports of the NHSN and INICC. A total of 368 VAP events were diagnosed during a 6-year period covering 76,749 ventilator days and 134,994 patient days. The overall VAP rate was 4.8 per 1,000 ventilator days (95% confidence interval, 4.3-5.3), with an overall ventilator utilization of 0.57. The VAP rates showed a wide variability between different types of intensive care units (ICUs) and were decreasing over time. After adjusting for the differences in ICU type, the risk of VAP in GCC hospitals was 217% higher than NHSN hospitals and 69% lower than INICC hospitals. The risk of VAP in ICU patients in GCC countries is higher than pooled U.S. VAP rates but lower than pooled rates from developing countries participating in the INICC. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Kallet, Richard H; Campbell, Andre R; Dicker, Rochelle A; Katz, Jeffrey A; Mackersie, Robert C
2005-12-01
Pressure-control ventilation (PCV) and pressure-regulated volume-control (PRVC) ventilation are used during lung-protective ventilation because the high, variable, peak inspiratory flow rate (V (I)) may reduce patient work of breathing (WOB) more than the fixed V (I) of volume-control ventilation (VCV). Patient-triggered breaths during PCV and PRVC may result in excessive tidal volume (V(T)) delivery unless the inspiratory pressure is reduced, which in turn may decrease the peak V (I). We tested whether PCV and PRVC reduce WOB better than VCV with a high, fixed peak V (I) (75 L/min) while also maintaining a low V(T) target. Fourteen nonconsecutive patients with acute lung injury or acute respiratory distress syndrome were studied prospectively, using a random presentation of ventilator modes in a crossover, repeated-measures design. A target V(T) of 6.4 + 0.5 mL/kg was set during VCV and PRVC. During PCV the inspiratory pressure was set to achieve the same V(T). WOB and other variables were measured with a pulmonary mechanics monitor (Bicore CP-100). There was a nonsignificant trend toward higher WOB (in J/L) during PCV (1.27 + 0.58 J/L) and PRVC (1.35 + 0.60 J/L), compared to VCV (1.09 + 0.59 J/L). While mean V(T) was not statistically different between modes, in 40% of patients, V(T) markedly exceeded the lung-protective ventilation target during PRVC and PCV. During lung-protective ventilation, PCV and PRVC offer no advantage in reducing WOB, compared to VCV with a high flow rate, and in some patients did not allow control of V(T) to be as precise.
Management and outcome of mechanically ventilated neurologic patients.
Pelosi, Paolo; Ferguson, Niall D; Frutos-Vivar, Fernando; Anzueto, Antonio; Putensen, Christian; Raymondos, Konstantinos; Apezteguia, Carlos; Desmery, Pablo; Hurtado, Javier; Abroug, Fekri; Elizalde, José; Tomicic, Vinko; Cakar, Nahit; Gonzalez, Marco; Arabi, Yaseen; Moreno, Rui; Esteban, Andres
2011-06-01
To describe and compare characteristics, ventilatory practices, and associated outcomes among mechanically ventilated patients with different types of brain injury and between neurologic and nonneurologic patients. Secondary analysis of a prospective, observational, and multicenter study on mechanical ventilation. Three hundred forty-nine intensive care units from 23 countries. We included 552 mechanically ventilated neurologic patients (362 patients with stroke and 190 patients with brain trauma). For comparison we used a control group of 4,030 mixed patients who were ventilated for nonneurologic reasons. None. We collected demographics, ventilatory settings, organ failures, and complications arising during ventilation and outcomes. Multivariate logistic regression analysis was performed with intensive care unit mortality as the dependent variable. At admission, a Glasgow Coma Scale score ≤8 was observed in 68% of the stroke, 77% of the brain trauma, and 29% of the nonneurologic patients. Modes of ventilation and use of a lung-protective strategy within the first week of mechanical ventilation were similar between groups. In comparison with nonneurologic patients, patients with neurologic disease developed fewer complications over the course of mechanical ventilation with the exception of a higher rate of ventilator-associated pneumonia in the brain trauma cohort. Neurologic patients showed higher rates of tracheotomy and longer duration of mechanical ventilation. Mortality in the intensive care unit was significantly (p < .001) higher in patients with stroke (45%) than in brain trauma (29%) and nonneurologic disease (30%). Factors associated with mortality were: stroke (in comparison to brain trauma), Glasgow Coma Scale score on day 1, and severity at admission in the intensive care unit. In our study, one of every five mechanically ventilated patients received this therapy as a result of a neurologic disease. This cohort of patients showed a higher mortality rate than nonneurologic patients despite a lower incidence of extracerebral organ dysfunction.
Potential Acceptability of a Pediatric Ventilator Management Computer Protocol.
Sward, Katherine A; Newth, Christopher J L; Khemani, Robinder G; Page, Kent; Meert, Kathleen L; Carcillo, Joseph A; Shanley, Thomas P; Moler, Frank W; Pollack, Murray M; Dalton, Heidi J; Wessel, David L; Berger, John T; Berg, Robert A; Harrison, Rick E; Doctor, Allan; Dean, J Michael; Holobkov, Richard; Jenkins, Tammara L; Nicholson, Carol E
2017-11-01
To examine issues regarding the granularity (size/scale) and potential acceptability of recommendations in a ventilator management protocol for children with pediatric acute respiratory distress syndrome. Survey/questionnaire. The eight PICUs in the Collaborative Pediatric Critical Care Research Network. One hundred twenty-two physicians (attendings and fellows). None. We used an online questionnaire to examine attitudes and assessed recommendations with 50 clinical scenarios. Overall 80% of scenario recommendations were accepted. Acceptance did not vary by provider characteristics but did vary by ventilator mode (high-frequency oscillatory ventilation 83%, pressure-regulated volume control 82%, pressure control 75%; p = 0.002) and variable adjusted (ranging from 88% for peak inspiratory pressure and 86% for FIO2 changes to 69% for positive end-expiratory pressure changes). Acceptance did not vary based on child size/age. There was a preference for smaller positive end-expiratory pressure changes but no clear granularity preference for other variables. Although overall acceptance rate for scenarios was good, there was little consensus regarding the size/scale of ventilator setting changes for children with pediatric acute respiratory distress syndrome. An acceptable protocol could support robust evaluation of ventilator management strategies. Further studies are needed to determine if adherence to an explicit protocol leads to better outcomes.
Cavalcante, Alexandre N; Martin, Yvette N; Sprung, Juraj; Imsirovic, Jasmin; Weingarten, Toby N
2017-12-20
An electrical impedance-based noninvasive respiratory volume monitor (RVM) accurately reports minute volume, tidal volume and respiratory rate. Here we used the RVM to quantify the occurrence of and evaluate the ability of clinical factors to predict respiratory depression in the post-anesthesia care unit (PACU). RVM generated respiratory data were collected from spontaneously breathing patients following intraperitoneal surgeries under general anesthesia admitted to the PACU. Respiratory depression was defined as low minute ventilation episode (LMVe, < 40% predicted minute ventilation for at least 2 min). We evaluated for associations between clinical variables including minute ventilation prior to opioid administration and LMVe following the first PACU administration of opioid. Also assessed was a low respiratory rate (< 8 breaths per minute) as a proxy for LMVe. Of 107 patients, 38 (36%) had LMVe. Affected patients had greater intraoperative opioid dose, P = 0.05. PACU opioids were administered to 45 (42.1%) subjects, of which 27 (25.2%) had LMVe (P = 0.42) within 30 min following opioid. Pre-opioid minute ventilation < 70% of predicted normal value was associated with LMVe, P < 0.01, (sensitivity = 100%, specificity = 81%).Low respiratory rate was a poor predictor of LMVe (sensitivity = 11.8%). Other clinical variables (e.g., obstructive sleep apnea) were not found to be predictors of LMVe. Using RVM we identified that mild, clinically nondetectable, respiratory depression prior to opioid administration in the PACU was associated with the development of substantial subsequent respiratory depression during the PACU stay.
Ventilation/odor study, field study. Final report, Volume I
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duffee, R.A.; Jann, P.
1981-04-01
The results are presented of field investigations in schools, hospitals, and an office building on the relation between ventilation rate and odor within the buildings. The primary objective of the study was to determine: the reduction in ventilation rates that could be achieved in public buildings without causing adverse effects on odor; the sources of odor in public buildings; and the identity of the odorants. The variables of particular interest include: type of odor, occupant density, odorant identity and concentration, differences in impressions between occupants adapted to prevailing conditions and visitors, and the influence of temperature and humidity on bothmore » the generation and perception of common contaminants. Sensory odor measurements, chemical measurements, fresh air ventilation measurements, and acceptability evaluations via questionnaires were made. Sensory odor levels were found to be quite low in most buildings tested. A three-to-five-fold reduction in the fresh air ventilation in schools, hospitals, and office buildings can be achieved without significantly affecting perceived odor intensities or detectability. Tobacco smoking was found to be the most significant, pervasive contributor to interior odor level. Total hydrocarbon content of indoor air varies directly with ventilation rates; odor, however, does not. The complete set of reduced data are contained in Volume II. (LEW)« less
A multiscale MDCT image-based breathing lung model with time-varying regional ventilation
Yin, Youbing; Choi, Jiwoong; Hoffman, Eric A.; Tawhai, Merryn H.; Lin, Ching-Long
2012-01-01
A novel algorithm is presented that links local structural variables (regional ventilation and deforming central airways) to global function (total lung volume) in the lung over three imaged lung volumes, to derive a breathing lung model for computational fluid dynamics simulation. The algorithm constitutes the core of an integrative, image-based computational framework for subject-specific simulation of the breathing lung. For the first time, the algorithm is applied to three multi-detector row computed tomography (MDCT) volumetric lung images of the same individual. A key technique in linking global and local variables over multiple images is an in-house mass-preserving image registration method. Throughout breathing cycles, cubic interpolation is employed to ensure C1 continuity in constructing time-varying regional ventilation at the whole lung level, flow rate fractions exiting the terminal airways, and airway deformation. The imaged exit airway flow rate fractions are derived from regional ventilation with the aid of a three-dimensional (3D) and one-dimensional (1D) coupled airway tree that connects the airways to the alveolar tissue. An in-house parallel large-eddy simulation (LES) technique is adopted to capture turbulent-transitional-laminar flows in both normal and deep breathing conditions. The results obtained by the proposed algorithm when using three lung volume images are compared with those using only one or two volume images. The three-volume-based lung model produces physiologically-consistent time-varying pressure and ventilation distribution. The one-volume-based lung model under-predicts pressure drop and yields un-physiological lobar ventilation. The two-volume-based model can account for airway deformation and non-uniform regional ventilation to some extent, but does not capture the non-linear features of the lung. PMID:23794749
Thibeau, Shelley; Boudreaux, Cynthia
2013-06-01
The purpose of this study was to explore the use of mothers' own milk (colostrums, transitional milk, and mature milk) as oral care in the ventilator-associated pneumonia (VAP)-prevention bundle of mechanically ventilated preterm infants weighing 1500 g or less. Mechanically ventilated preterm infants weighing 1500 g or less admitted to a regional level III NICU in the Gulf South between January 1, 2006, and December 31, 2009. Retrospective descriptive. Oral care with mothers' own milk was implemented as part of the VAP-prevention bundle in the neonatal intensive care unit in the fourth quarter of 2007. Using retrospective deidentified data retrieved from the electronic medical record, the primary and secondary outcome variables were collected among eligible infants (≤1500 g) admitted January 1, 2006, to December 31, 2007 (before implementation) and January 1, 2008, to December 31, 2009 (after implementation). Sample characteristics, including infant gestational age, birth weight, and gender, as well as maternal age, type of delivery, and incidence of maternal chorioamnionitis, were also collected. Data analysis included frequencies and distributions to summarize sample characteristics and variables of interest. Appropriate tests for differences were conducted on outcome variables between the before and after groups of the human milk oral care intervention. The feasibility outcome variable included nursing compliance with the oral care procedure. The safety outcome variable included record of any adverse events associated with the oral care procedure. The efficacy health outcomes included the rate of positive tracheal aspirates, positive blood cultures, the number of ventilator days, and length of stay. Infant age (26.1-26.6 weeks) and weight (840-863 g) were similar in the before (n = 70) and after (n = 68) sample subjects. There were no statistically significant differences in ventilator days, χ² (46, n = 115) = 46.22, P = .46, and length of stay, χ (75, n = 115) = 78.78, P = .36, between groups. Although the rate of positive tracheal aspirates and positive blood cultures reduced after implementation of oral care with mothers' own milk, these differences were not statistically significant (U(47) = 250, z = -7.1, P = .48; U(47) = 217.5, z = -1.44, P = .15). There were no statistically significant differences in the rates of positive tracheal aspirates and blood cultures after implementation of oral care with mothers' own milk. The findings of this study suggest that using mothers' own milk as part of the VAP-prevention bundle is a feasible and safe practice; however, further research is needed to determine the immunological benefits of this practice.
Spieth, Peter M; Güldner, Andreas; Uhlig, Christopher; Bluth, Thomas; Kiss, Thomas; Schultz, Marcus J; Pelosi, Paolo; Koch, Thea; Gama de Abreu, Marcelo
2014-05-02
General anesthesia usually requires mechanical ventilation, which is traditionally accomplished with constant tidal volumes in volume- or pressure-controlled modes. Experimental studies suggest that the use of variable tidal volumes (variable ventilation) recruits lung tissue, improves pulmonary function and reduces systemic inflammatory response. However, it is currently not known whether patients undergoing open abdominal surgery might benefit from intraoperative variable ventilation. The PROtective VARiable ventilation trial ('PROVAR') is a single center, randomized controlled trial enrolling 50 patients who are planning for open abdominal surgery expected to last longer than 3 hours. PROVAR compares conventional (non-variable) lung protective ventilation (CV) with variable lung protective ventilation (VV) regarding pulmonary function and inflammatory response. The primary endpoint of the study is the forced vital capacity on the first postoperative day. Secondary endpoints include further lung function tests, plasma cytokine levels, spatial distribution of ventilation assessed by means of electrical impedance tomography and postoperative pulmonary complications. We hypothesize that VV improves lung function and reduces systemic inflammatory response compared to CV in patients receiving mechanical ventilation during general anesthesia for open abdominal surgery longer than 3 hours. PROVAR is the first randomized controlled trial aiming at intra- and postoperative effects of VV on lung function. This study may help to define the role of VV during general anesthesia requiring mechanical ventilation. Clinicaltrials.gov NCT01683578 (registered on September 3 3012).
Bowton, David L; Hite, R Duncan; Martin, R Shayn; Sherertz, Robert
2013-10-01
Aspiration of colonized oropharyngeal secretions is a major factor in the pathogenesis of ventilator-associated pneumonia (VAP). A tapered-cuff endotracheal tube (ETT) has been demonstrated to reduce aspiration around the cuff. Whether these properties are efficacious in reducing VAP is not known. This 2-period, investigator-initiated observational study was designed to assess the efficacy of a tapered-cuff ETT to reduce the VAP rate. All intubated, mechanically ventilated patients over the age of 18 were included. During the baseline period a standard, barrel-shaped-cuff ETT (Mallinckrodt Hi-Lo) was used. All ETTs throughout the hospital were then replaced with a tapered-cuff ETT (TaperGuard). The primary outcome variable was the incidence of VAP per 1,000 ventilator days. We included 2,849 subjects, encompassing 15,250 ventilator days. The mean ± SD monthly VAP rate was 3.29 ± 1.79/1,000 ventilator days in the standard-cuff group and 2.77 ± 2.00/1,000 ventilator days in the tapered-cuff group (P = .65). While adherence to the VAP prevention bundle was high throughout the study, bundle adherence was significantly higher during the standard-cuff period (96.5 ± 2.7%) than in the tapered-cuff period (90.3 ± 3.5%, P = .01). In the setting of a VAP rate very near the average of ICUs in the United States, and where there was high adherence to a VAP prevention bundle, the use of a tapered-cuff ETT was not associated with a reduction in the VAP rate.
Seluianov, V N; Kalinin, E M; Pak, G D; Maevskaia, V I; Konrad, A H
2011-01-01
The aim of this work is to develop methods for determining the anaerobic threshold according to the rate of ventilation and cardio interval variability during the test with stepwise increases load on the cycle ergometer and treadmill. In the first phase developed the method for determining the anaerobic threshold for lung ventilation. 49 highly skilled skiers took part in the experiment. They performed a treadmill ski-walking test with sticks with gradually increasing slope from 0 to 25 degrees, the slope increased by one degree every minute. In the second phase we developed a method for determining the anaerobic threshold according dynamics ofcardio interval variability during the test. The study included 86 athletes of different sports specialties who performed pedaling on the cycle ergometer "Monarch" in advance. Initial output was 25 W, power increased by 25 W every 2 min. The pace was steady--75 rev/min. Measurement of pulmonary ventilation and oxygen and carbon dioxide content was performed using gas analyzer COSMED K4. Sampling of arterial blood was carried from the ear lobe or finger, blood lactate concentration was determined using an "Akusport" instrument. RR-intervals registration was performed using heart rate monitor Polar s810i. As a result, it was shown that the graphical method for determining the onset of anaerobic threshold ventilation (VAnP) coincides with the accumulation of blood lactate 3.8 +/- 0.1 mmol/l when testing on a treadmill and 4.1 +/- 0.6 mmol/1 on the cycle ergometer. The connection between the measure of oxygen consumption at VAnP and the dispersion of cardio intervals (SD1), derived regression equation: VO2AnT = 0.35 + 0.01SD1W + 0.0016SD1HR + + 0.106SD1(ms), l/min; (R = 0.98, error evaluation function 0.26 L/min, p < 0.001), where W (W)--Power, HR--heart rate (beats/min), SD1--cardio intervals dispersion (ms) at the moment of registration of cardio interval threshold.
Indoor air quality in Portuguese schools: levels and sources of pollutants.
Madureira, J; Paciência, I; Pereira, C; Teixeira, J P; Fernandes, E de O
2016-08-01
Indoor air quality (IAQ) parameters in 73 primary classrooms in Porto were examined for the purpose of assessing levels of volatile organic compounds (VOCs), aldehydes, particulate matter, ventilation rates and bioaerosols within and between schools, and potential sources. Levels of VOCs, aldehydes, PM2.5 , PM10 , bacteria and fungi, carbon dioxide (CO2 ), carbon monoxide, temperature and relative humidity were measured indoors and outdoors and a walkthrough survey was performed concurrently. Ventilation rates were derived from CO2 and occupancy data. Concentrations of CO2 exceeding 1000 ppm were often encountered, indicating poor ventilation. Most VOCs had low concentrations (median of individual species <5 μg/m(3) ) and were below the respective WHO guidelines. Concentrations of particulate matter and culturable bacteria were frequently higher than guidelines/reference values. The variability of VOCs, aldehydes, bioaerosol concentrations, and CO2 levels between schools exceeded the variability within schools. These findings indicate that IAQ problems may persist in classrooms where pollutant sources exist and classrooms are poorly ventilated; source control strategies (related to building location, occupant behavior, maintenance/cleaning activities) are deemed to be the most reliable for the prevention of adverse health consequences in children in schools. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Purging of working atmospheres inside freight containers.
Braconnier, Robert; Keller, François-Xavier
2015-06-01
This article focuses on prevention of possible exposure to chemical agents, when opening, entering, and stripping freight containers. The container purging process is investigated using tracer gas measurements and numerical airflow simulations. Three different container ventilation conditions are studied, namely natural, mixed mode, and forced ventilation. The tests conducted allow purging time variations to be quantified in relation to various factors such as container size, degree of filling, or type of load. Natural ventilation performance characteristics prove to be highly variable, depending on environmental conditions. Use of a mechanically supplied or extracted airflow under mixed mode and forced ventilation conditions enables purging to be significantly accelerated. Under mixed mode ventilation, extracting air from the end of the container furthest from the door ensures quicker purging than supplying fresh air to this area. Under forced ventilation, purging rate is proportional to the applied ventilation flow. Moreover, purging rate depends mainly on the location at which air is introduced: the most favourable position being above the container loading level. Many of the results obtained during this study can be generalized to other cases of purging air in a confined space by general ventilation, e.g. the significance of air inlet positioning or the advantage of generating high air velocities to maximize stirring within the volume. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Hartung, Julia C; Dold, Simone K; Thio, Marta; tePas, Arjan; Schmalisch, Gerd; Roehr, Charles Christoph
2014-06-01
Resuscitation guidelines give no preference over use of self-inflating bags (SIBs) or T-piece resuscitators (TPR) for manual neonatal ventilation. We speculated that devices would differ significantly regarding time required to adjust to changed ventilation settings. This was a laboratory study. Time to adjust from baseline peak inflation pressure (PIP) (20 cmH2O) to target PIP (25 and 40 cmH2O), ability to adhere to predefined ventilation settings (PIP, PEEP, and inflation rate [IR]), and the variability within and between operators were assessed for a SIB without manometer, SIB with manometer (SIBM), and two TPRs. Adjustment time was significantly longer with TPRs, compared with SIB and SIBM. The SIBM and TPRs were < 5% (median) off target PIP, and the SIB was 14% off target PIP. Significant variability between operators (interquartile range [IQR]: 71%) was seen with SIBs. PIP adjustment takes longer with TPRs, compared with SIB/SIBM. TPRs and SIBM allow satisfactory adherence to ventilation parameters. SIBs should only be used with manometer attached. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Effect of cabin ventilation rate on ultrafine particle exposure inside automobiles.
Knibbs, Luke D; de Dear, Richard J; Morawska, Lidia
2010-05-01
We alternately measured on-road and in-vehicle ultrafine (<100 nm) particle (UFP) concentration for 5 passenger vehicles that comprised an age range of 18 years. A range of cabin ventilation settings were assessed during 301 trips through a 4 km road tunnel in Sydney, Australia. Outdoor air flow (ventilation) rates under these settings were quantified on open roads using tracer gas techniques. Significant variability in tunnel trip average median in-cabin/on-road (I/O) UFP ratios was observed (0.08 to approximately 1.0). Based on data spanning all test automobiles and ventilation settings, a positive linear relationship was found between outdoor air flow rate and I/O ratio, with the former accounting for a substantial proportion of variation in the latter (R(2) = 0.81). UFP concentrations recorded in-cabin during tunnel travel were significantly higher than those reported by comparable studies performed on open roadways. A simple mathematical model afforded the ability to predict tunnel trip average in-cabin UFP concentrations with good accuracy. Our data indicate that under certain conditions, in-cabin UFP exposures incurred during tunnel travel may contribute significantly to daily exposure. The UFP exposure of automobile occupants appears strongly related to their choice of ventilation setting and vehicle.
Wenzel, V; Idris, A H; Dörges, V; Nolan, J P; Parr, M J; Gabrielli, A; Stallinger, A; Lindner, K H; Baskett, P J
2001-05-01
The fear of acquiring infectious diseases has resulted in reluctance among healthcare professionals and the lay public to perform mouth-to-mouth ventilation. However, the benefit of basic life support for a patient in cardiopulmonary or respiratory arrest greatly outweighs the risk for secondary infection in the rescuer or the patient. The distribution of ventilation volume between lungs and stomach in the unprotected airway depends on patient variables such as lower oesophageal sphincter pressure, airway resistance and respiratory system compliance, and the technique applied while performing basic or advanced airway support, such as head position, inflation flow rate and time, which determine upper airway pressure. The combination of these variables determines gas distribution between the lungs and the oesophagus and subsequently, the stomach. During bag-valve-mask ventilation of patients in respiratory or cardiac arrest with oxygen supplementation (> or = 40% oxygen), a tidal volume of 6-7 ml kg(-1) ( approximately 500 ml) given over 1-2 s until the chest rises is recommended. For bag-valve-mask ventilation with room-air, a tidal volume of 10 ml kg(-1) (700-1000 ml) in an adult given over 2 s until the chest rises clearly is recommended. During mouth-to-mouth ventilation, a breath over 2 s sufficient to make the chest rise clearly (a tidal volume of approximately 10 ml kg(-1) approximately 700-1000 ml in an adult) is recommended.
NASA Astrophysics Data System (ADS)
Mutch, W. Alan C.
2005-05-01
Life support with a mechanical ventilator is used to manage patients with a variety of lung diseases including acute respiratory distress syndrome (ARDS). Recently, management of ARDS has concentrated on ventilating at lower airway pressure using lower tidal volume. A large international study demonstrated a 22% reduction in mortality with the low tidal volume approach. The potential advantages of adding physiologic noise with fractal characteristics to the respiratory rate and tidal volume as delivered by a mechanical ventilator are discussed. A so-called biologically variable ventilator (BVV), incorporating such noise, has been developed. Here we show that the benefits of noisy ventilation - at lower tidal volumes - can be deduced from a simple probabilistic result known as Jensen"s Inequality. Using the local convexity of the pressure-volume relationship in the lung we demonstrate that the addition of noise results in higher mean tidal volume or lower mean airway pressure. The consequence is enhanced gas exchange or less stress on the lungs, both clinically desirable. Jensen"s Inequality has important considerations in engineering, information theory and thermodynamics. Here is an example of the concept applied to medicine that may have important considerations for the clinical management of critically ill patients. Life support devices, such as mechanical ventilators, are of vital use in critical care units and operating rooms. These devices usually have monotonous output. Improving mechanical ventilators and other life support devices may be as simple as adding noise to their output signals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lunden, Melissa; Faulkner, David; Heredia, Elizabeth
2012-10-01
This report documents experiments performed in three homes to assess the methodology used to determine air exchange rates using passive tracer techniques. The experiments used four different tracer gases emitted simultaneously but implemented with different spatial coverage in the home. Two different tracer gas sampling methods were used. The results characterize the factors of the execution and analysis of the passive tracer technique that affect the uncertainty in the calculated air exchange rates. These factors include uncertainties in tracer gas emission rates, differences in measured concentrations for different tracer gases, temporal and spatial variability of the concentrations, the comparison betweenmore » different gas sampling methods, and the effect of different ventilation conditions.« less
Thomas, Patricia E; LeFlore, Judy
2013-01-01
Infants born prematurely with respiratory distress syndrome are at high risk for complications from mechanical ventilation. Strategies are needed to minimize their days on the ventilator. The purpose of this study was to compare extubation success rates in infants treated with 2 different types of continuous positive airway pressure devices. A retrospective cohort study design was used. Data were retrieved from electronic medical records for patients in a large, metropolitan, level III neonatal intensive care unit. A sample of 194 premature infants with respiratory distress syndrome was selected, 124 of whom were treated with nasal intermittent positive pressure ventilation and 70 with bi-level variable flow nasal continuous positive airway pressure (bi-level nasal continuous positive airway pressure). Infants in both groups had high extubation success rates (79% of nasal intermittent positive pressure ventilation group and 77% of bi-level nasal continuous positive airway pressure group). Although infants in the bi-level nasal continuous positive airway pressure group were extubated sooner, there was no difference in duration of oxygen therapy between the 2 groups. Promoting early extubation and extubation success is a vital strategy to reduce complications of mechanical ventilation that adversely affect premature infants with respiratory distress syndrome.
Previous exposure assessment panel studies have observed considerable seasonal, between-home and between-city variability in residential pollutant infiltration. This is likely a result of differences in home ventilation, or air exchange rates (AER). The Stochastic Human Exposure ...
Energy expenditure during barbiturate coma.
Ashcraft, Christine M; Frankenfield, David C
2013-10-01
Barbiturate coma may have a significant effect on metabolic rate, but the phenomenon is not extensively studied. The primary purpose of the current study was to compare the metabolic rate of general critical care patients with those requiring barbiturate coma. A secondary purpose was to evaluate the accuracy of the Penn State prediction equation between these 2 groups of patients. Indirect calorimetry was used to measure the resting metabolic rate of mechanically ventilated, critically ill patients in a barbiturate coma and those of similar height, weight, and age but not in a barbiturate coma. Measurements of resting metabolic rate were compared with predictions using the Penn State equation accounting for body size, body temperature, and minute ventilation. The barbiturate coma group had a lower resting metabolic rate than the control group that remained lower even after adjustment for predicted healthy metabolic rate and maximum body temperature (1859 ± 290 vs 2037 ± 289 kcal/d, P = .020). When minute ventilation was also included in the analysis, the resting metabolic rate between the groups became statistically insignificant (1929 ± 229 vs 2023 ± 226 kcal/d, P = .142). The Penn State equation, which uses these variables, was accurate in 73% of the control patients and also the barbiturate coma patients. Resting metabolic rate is moderately reduced in barbiturate coma, but the decrease is out of proportion with changes in body temperature. However, if both body temperature and minute ventilation are considered, then the change is predictable.
Yoshida, Takeshi; Uchiyama, Akinori; Matsuura, Nariaki; Mashimo, Takashi; Fujino, Yuji
2012-05-01
We investigated whether potentially injurious transpulmonary pressure could be generated by strong spontaneous breathing and exacerbate lung injury even when plateau pressure is limited to <30 cm H2O. Prospective, randomized, animal study. University animal research laboratory. Thirty-two New Zealand White rabbits. Lavage-injured rabbits were randomly allocated to four groups to receive low or moderate tidal volume ventilation, each combined with weak or strong spontaneous breathing effort. Inspiratory pressure for low tidal volume ventilation was set at 10 cm H2O and tidal volume at 6 mL/kg. For moderate tidal volume ventilation, the values were 20 cm H2O and 7-9 mL/kg. The groups were: low tidal volume ventilation+spontaneous breathingweak, low tidal volume ventilation+spontaneous breathingstrong, moderate tidal volume ventilation+spontaneous breathingweak, and moderate tidal volume ventilation+spontaneous breathingstrong. Each group had the same settings for positive end-expiratory pressure of 8 cm H2O. Respiratory variables were measured every 60 mins. Distribution of lung aeration and alveolar collapse were histologically evaluated. Low tidal volume ventilation+spontaneous breathingstrong showed the most favorable oxygenation and compliance of respiratory system, and the best lung aeration. By contrast, in moderate tidal volume ventilation+spontaneous breathingstrong, the greatest atelectasis with numerous neutrophils was observed. While we applied settings to maintain plateau pressure at <30 cm H2O in all groups, in moderate tidal volume ventilation+spontaneous breathingstrong, transpulmonary pressure rose >33 cm H2O. Both minute ventilation and respiratory rate were higher in the strong spontaneous breathing groups. Even when plateau pressure is limited to <30 cm H2O, combined with increased respiratory rate and tidal volume, high transpulmonary pressure generated by strong spontaneous breathing effort can worsen lung injury. When spontaneous breathing is preserved during mechanical ventilation, transpulmonary pressure and tidal volume should be strictly controlled to prevent further lung injury.
Variability in home mechanical ventilation prescription.
Escarrabill, Joan; Tebé, Cristian; Espallargues, Mireia; Torrente, Elena; Tresserras, Ricard; Argimón, J
2015-10-01
Few studies have analyzed the prevalence and accessibility of home mechanical ventilation (HMV). The aim of this study was to characterize the prevalence of HMV and variability in prescriptions from administrative data. Prescribing rates of HMV in the 37 healthcare sectors of the Catalan Health Service were compared from billing data from 2008 to 2011. Crude accumulated activity rates (per 100,000 population) were calculated using systematic component of variation (SCV) and empirical Bayes (EB) methods. Standardized activity ratios (SAR) were described using a map of healthcare sectors. A crude rate of 23 HMV prescriptions per 100,000 population was observed. Rates increase with age and have increased by 39%. Statistics measuring variation not due to chance show a high variation in women (CSV=0.20 and EB=0.30) and in men (CSV=0.21 and EB=0.40), and were constant over time. In a multilevel Poisson model, hospitals with a chest unit were associated with a greater number of cases (beta=0.68, P<.0001). High variability in prescribing HMV can be explained, in part, by the attitude of professionals towards treatment and accessibility to specialist centers with a chest unit. Analysis of administrative data and variability mapping help identify unexplained variations and, in the absence of systematic records, are a feasible way of tracking treatment. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.
between-home and between-city variability in residential pollutant infiltration. This is likely a result of differences in home ventilation, or air exchange rates (AER). The Stochastic Human Exposure and Dose Simulation (SHEDS) model is a population exposure model that uses a pro...
Ruggieri, Francesco; Beretta, Luigi; Corno, Laura; Testa, Valentina; Martino, Enrico A; Gemma, Marco
2017-06-30
Traditional ventilation approaches, providing high tidal volumes (Vt), produce excessive alveolar distention and lung injury. Protective ventilation, employing lower Vt and positive end-expiratory pressure (PEEP), is an attractive alternative also for neuroanesthesia, when prolonged mechanical ventilation is needed. Nevertheless, protective ventilation during intracranial surgery may exert dangerous effects on intracranial pressure (ICP). We tested the feasibility of a protective ventilation strategy in neurosurgery. Our monocentric, double-blind, 1:1 randomized, 2×2 crossover study aimed at studying the effect size and variability of ICP in patients undergoing elective supratentorial brain tumor removal and alternatively ventilated with Vt 9 mL/kg-PEEP 0 mm Hg and Vt 7 mL/kg-PEEP 5 mm Hg. Respiratory rate was adjusted to maintain comparable end-tidal carbon dioxide between ventilation modes. ICP was measured through a subdural catheter inserted before dural opening. Forty patients were enrolled; 8 (15%) were excluded after enrollment. ICP did not differ between traditional and protective ventilation (11.28±5.37, 11 [7 to 14.5] vs. 11.90±5.86, 11 [8 to 15] mm Hg; P=0.541). End-tidal carbon dioxide (28.91±2.28, 29 [28 to 30] vs. 28.00±2.17, 28 [27 to 29] mm Hg; P<0.001). Peak airway pressure (17.25±1.97, 17 [16 to 18.5] vs. 15.81±2.87, 15.5 [14 to 17] mm Hg; P<0.001) and plateau airway pressure (16.06±2.30, 16 [14.5 to 17] vs. 14.19±2.82, 14 [12.5 to 16] mm Hg; P<0.001) were higher during protective ventilation. Blood pressure, heart rate, and body temperature did not differ between ventilation modes. Dural tension was "acceptable for surgery" in all cases. ICP differences between ventilation modes were not affected by ICP values under traditional ventilation (coefficient=0.067; 95% confidence interval, -0.278 to 0.144; P=0.523). Protective ventilation is a feasible alternative to traditional ventilation during elective neurosurgery.
Echocardiographic evaluation during weaning from mechanical ventilation.
Schifelbain, Luciele Medianeira; Vieira, Silvia Regina Rios; Brauner, Janete Salles; Pacheco, Deise Mota; Naujorks, Alexandre Antonio
2011-01-01
Echocardiographic, electrocardiographic and other cardiorespiratory variables can change during weaning from mechanical ventilation. To analyze changes in cardiac function, using Doppler echocardiogram, in critical patients during weaning from mechanical ventilation, using two different weaning methods: pressure support ventilation and T-tube; and comparing patient subgroups: success vs. failure in weaning. Randomized crossover clinical trial including patients under mechanical ventilation for more than 48 h and considered ready for weaning. Cardiorespiratory variables, oxygenation, electrocardiogram and Doppler echocardiogram findings were analyzed at baseline and after 30 min in pressure support ventilation and T-tube. Pressure support ventilation vs. T-tube and weaning success vs. failure were compared using ANOVA and Student's t-test. The level of significance was p<0.05. Twenty-four adult patients were evaluated. Seven patients failed at the first weaning attempt. No echocardiographic or electrocardiographic differences were observed between pressure support ventilation and T-tube. Weaning failure patients presented increases in left atrium, intraventricular septum thickness, posterior wall thickness and diameter of left ventricle and shorter isovolumetric relaxation time. Successfully weaned patients had higher levels of oxygenation. No differences were observed between Doppler echocardiographic variables and electrocardiographic and other cardiorespiratory variables during pressure support ventilation and T-tube. However cardiac structures were smaller, isovolumetric relaxation time was larger, and oxygenation level was greater in successfully weaned patients.
Zhou, Jing; Han, Yi
2016-01-01
To analyze the ability of pleth variability index (PVI) and respiratory system compliance (RSC) on evaluating the hemodynamic and respiratory effects of positive end expiratory pressure (PEEP), then to direct PEEP settings in mechanically ventilated critical patients. We studied 22 mechanically ventilated critical patients in the intensive care unit. Patients were monitored with classical monitor and a pulse co-oximeter, with pulse sensors attached to patients' index fingers. Hemodynamic data [heart rate (HR), perfusion index (PI), PVI, central venous pressure (CVP), mean arterial pressure (MAP), peripheral blood oxygen saturation (SPO2), peripheral blood oxygen content (SPOC) and peripheral blood hemoglobin (SPHB)] as well as the respiratory data [respiratory rate (RR), tidal volume (VT), RSC and controlled airway pressure] were recorded for 15 min each at 3 different levels of PEEP (0, 5 and 10 cmH2O). Different levels of PEEP (0, 5 and 10 cmH2O) had no obvious effect on RR, HR, MAP, SPO2 and SPOC. However, 10 cmH2O PEEP induced significant hemodynamic disturbances, including decreases of PI, and increases of both PVI and CVP. Meanwhile, 5 cmH2O PEEP induced no significant changes on hemodynamics such as CVP, PI and PVI, but improved the RSC. RSC and PVI may be useful in detecting the hemodynamic and respiratory effects of PEEP, thus may help clinicians individualize PEEP settings in mechanically ventilated patients.
Gas exchange and ventilation during dormancy in the tegu lizard tupinambis merianae
de Andrade DV; Abe
1999-12-01
The tegu lizard Tupinambis merianae exhibits an episodic ventilatory pattern when dormant at 17 degrees C but a uniform ventilatory pattern when dormant at 25 degrees C. At 17 degrees C, ventilatory episodes were composed of 1-22 breaths interspaced by non-ventilatory periods lasting 1.8-26 min. Dormancy at the higher body temperature was accompanied by higher rates of O(2) consumption and ventilation. The increase in ventilation was due only to increases in breathing frequency with no change observed in tidal volume. The air convection requirement for O(2) did not differ at the two body temperatures. The respiratory quotient was 0.8 at 17 degrees C and 1.0 at 25 degrees C. We found no consistent relationship between expired gas composition and the start/end of the ventilatory period during episodic breathing at 17 degrees C. However, following non-ventilatory periods of increasing duration, there was an increase in the pulmonary O(2) extraction that was not coupled to an equivalent increase in elimination of CO(2) from the lungs. None of the changes in the variables studied could alone explain the initiation/termination of episodic ventilation in the tegus, suggesting that breathing episodes are shaped by a complex interaction between many variables. The estimated oxidative cost of breathing in dormant tegus at 17 degrees C was equivalent to 52.3 % of the total metabolic rate, indicating that breathing is the most costly activity during dormancy.
Variable tidal volumes improve lung protective ventilation strategies in experimental lung injury.
Spieth, Peter M; Carvalho, Alysson R; Pelosi, Paolo; Hoehn, Catharina; Meissner, Christoph; Kasper, Michael; Hübler, Matthias; von Neindorff, Matthias; Dassow, Constanze; Barrenschee, Martina; Uhlig, Stefan; Koch, Thea; de Abreu, Marcelo Gama
2009-04-15
Noisy ventilation with variable Vt may improve respiratory function in acute lung injury. To determine the impact of noisy ventilation on respiratory function and its biological effects on lung parenchyma compared with conventional protective mechanical ventilation strategies. In a porcine surfactant depletion model of lung injury, we randomly combined noisy ventilation with the ARDS Network protocol or the open lung approach (n = 9 per group). Respiratory mechanics, gas exchange, and distribution of pulmonary blood flow were measured at intervals over a 6-hour period. Postmortem, lung tissue was analyzed to determine histological damage, mechanical stress, and inflammation. We found that, at comparable minute ventilation, noisy ventilation (1) improved arterial oxygenation and reduced mean inspiratory peak airway pressure and elastance of the respiratory system compared with the ARDS Network protocol and the open lung approach, (2) redistributed pulmonary blood flow to caudal zones compared with the ARDS Network protocol and to peripheral ones compared with the open lung approach, (3) reduced histological damage in comparison to both protective ventilation strategies, and (4) did not increase lung inflammation or mechanical stress. Noisy ventilation with variable Vt and fixed respiratory frequency improves respiratory function and reduces histological damage compared with standard protective ventilation strategies.
Flow measurement in mechanical ventilation: a review.
Schena, Emiliano; Massaroni, Carlo; Saccomandi, Paola; Cecchini, Stefano
2015-03-01
Accurate monitoring of flow rate and volume exchanges is essential to minimize ventilator-induced lung injury. Mechanical ventilators employ flowmeters to estimate the amount of gases delivered to patients and use the flow signal as a feedback to adjust the desired amount of gas to be delivered. Since flowmeters play a crucial role in this field, they are required to fulfill strict criteria in terms of dynamic and static characteristics. Therefore, mechanical ventilators are equipped with only the following kinds of flowmeters: linear pneumotachographs, fixed and variable orifice meters, hot wire anemometers, and ultrasonic flowmeters. This paper provides an overview of these sensors. Their working principles are described together with their relevant advantages and disadvantages. Furthermore, the most promising emerging approaches for flowmeters design (i.e., fiber optic technology and three dimensional micro-fabrication) are briefly reviewed showing their potential for this application. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Chang, Suchi; Shi, Jindong; Fu, Cuiping; Wu, Xu; Li, Shanqun
2016-01-01
Background COPD is the third leading cause of death worldwide. Acute exacerbations of COPD may cause respiratory failure, requiring intensive care unit admission and mechanical ventilation. Intensive care unit patients with acute exacerbations of COPD requiring mechanical ventilation have higher mortality rates than other hospitalized patients. Although mechanical ventilation is the most effective intervention for these conditions, invasive ventilation techniques have yielded variable effects. Objective We evaluated pressure-regulated volume control (PRVC) ventilation treatment efficacy and preventive effects on pulmonary barotrauma in elderly COPD patients with respiratory failure. Patients and methods Thirty-nine intubated patients were divided into experimental and control groups and treated with the PRVC and synchronized intermittent mandatory ventilation – volume control methods, respectively. Vital signs, respiratory mechanics, and arterial blood gas analyses were monitored for 2–4 hours and 48 hours. Results Both groups showed rapidly improved pH, partial pressure of oxygen (PaO2), and PaO2 per fraction of inspired O2 levels and lower partial pressure of carbon dioxide (PaCO2) levels. The pH and PaCO2 levels at 2–4 hours were lower and higher, respectively, in the test group than those in the control group (P<0.05 for both); after 48 hours, blood gas analyses showed no statistical difference in any marker (P>0.05). Vital signs during 2–4 hours and 48 hours of treatment showed no statistical difference in either group (P>0.05). The level of peak inspiratory pressure in the experimental group after mechanical ventilation for 2–4 hours and 48 hours was significantly lower than that in the control group (P<0.05), while other variables were not significantly different between groups (P>0.05). Conclusion Among elderly COPD patients with respiratory failure, application of PRVC resulted in rapid improvement in arterial blood gas analyses while maintaining a low peak inspiratory pressure. PRVC can reduce pulmonary barotrauma risk, making it a safer protective ventilation mode than synchronized intermittent mandatory ventilation – volume control. PMID:27274223
Chang, Suchi; Shi, Jindong; Fu, Cuiping; Wu, Xu; Li, Shanqun
2016-01-01
COPD is the third leading cause of death worldwide. Acute exacerbations of COPD may cause respiratory failure, requiring intensive care unit admission and mechanical ventilation. Intensive care unit patients with acute exacerbations of COPD requiring mechanical ventilation have higher mortality rates than other hospitalized patients. Although mechanical ventilation is the most effective intervention for these conditions, invasive ventilation techniques have yielded variable effects. We evaluated pressure-regulated volume control (PRVC) ventilation treatment efficacy and preventive effects on pulmonary barotrauma in elderly COPD patients with respiratory failure. Thirty-nine intubated patients were divided into experimental and control groups and treated with the PRVC and synchronized intermittent mandatory ventilation - volume control methods, respectively. Vital signs, respiratory mechanics, and arterial blood gas analyses were monitored for 2-4 hours and 48 hours. Both groups showed rapidly improved pH, partial pressure of oxygen (PaO2), and PaO2 per fraction of inspired O2 levels and lower partial pressure of carbon dioxide (PaCO2) levels. The pH and PaCO2 levels at 2-4 hours were lower and higher, respectively, in the test group than those in the control group (P<0.05 for both); after 48 hours, blood gas analyses showed no statistical difference in any marker (P>0.05). Vital signs during 2-4 hours and 48 hours of treatment showed no statistical difference in either group (P>0.05). The level of peak inspiratory pressure in the experimental group after mechanical ventilation for 2-4 hours and 48 hours was significantly lower than that in the control group (P<0.05), while other variables were not significantly different between groups (P>0.05). Among elderly COPD patients with respiratory failure, application of PRVC resulted in rapid improvement in arterial blood gas analyses while maintaining a low peak inspiratory pressure. PRVC can reduce pulmonary barotrauma risk, making it a safer protective ventilation mode than synchronized intermittent mandatory ventilation - volume control.
Kornblith, Lucy Z; Kutcher, Matthew E; Callcut, Rachael A; Redick, Brittney J; Hu, Charles K; Cogbill, Thomas H; Baker, Christopher C; Shapiro, Mark L; Burlew, Clay C; Kaups, Krista L; DeMoya, Marc A; Haan, James M; Koontz, Christopher H; Zolin, Samuel J; Gordy, Stephanie D; Shatz, David V; Paul, Doug B; Cohen, Mitchell J
2013-12-01
Respiratory failure after acute spinal cord injury (SCI) is well recognized, but data defining which patients need long-term ventilator support and criteria for weaning and extubation are lacking. We hypothesized that many patients with SCI, even those with cervical SCI, can be successfully managed without long-term mechanical ventilation and its associated morbidity. Under the auspices of the Western Trauma Association Multi-Center Trials Group, a retrospective study of patients with SCI at 14 major trauma centers was conducted. Comprehensive injury, demographic, and outcome data on patients with acute SCI were compiled. The primary outcome variable was the need for mechanical ventilation at discharge. Secondary outcomes included the use of tracheostomy and development of acute lung injury and ventilator-associated pneumonia. A total of 360 patients had SCI requiring mechanical ventilation. Sixteen patients were excluded for death within the first 2 days of hospitalization. Of the 344 patients included, 222 (64.5%) had cervical SCI. Notably, 62.6% of the patients with cervical SCI were ventilator free by discharge. One hundred forty-nine patients (43.3%) underwent tracheostomy, and 53.7% of them were successfully weaned from the ventilator, compared with an 85.6% success rate among those with no tracheostomy (p < 0.05). Patients who underwent tracheostomy had significantly higher rates of ventilator-associated pneumonia (61.1% vs. 20.5%, p < 0.05) and acute lung injury (12.8% vs. 3.6%, p < 0.05) and fewer ventilator-free days (1 vs. 24 p < 0.05). When controlled for injury severity, thoracic injury, and respiratory comorbidities, tracheostomy after cervical SCI was an independent predictor of ventilator dependence with an associated 14-fold higher likelihood of prolonged mechanical ventilation (odds ratio, 14.1; 95% confidence interval, 2.78-71.67; p < 0.05). While many patients with SCI require short-term mechanical ventilation, the majority can be successfully weaned before discharge. In patients with SCI, tracheostomy is associated with major morbidity, and its use, especially among patients with cervical SCI, deserves further study. Prognostic study, level III.
Function of the Dräger Oxylog ventilator at high altitude.
Thomas, G; Brimacombe, J
1994-06-01
We have assessed the performance of the Dräger Oxylog ventilator at high altitude using a decompression chamber and a lung simulator set to mimic the normal and non-compliant lung. In the normal lung, tidal volume increased by 28% at 2040 metres and by 106% at 9120 metres. A lesser change, but in the opposite direction, occurred in respiratory rate. The net effect was a linear increase in minute volume with altitude. At 2040 and 9144 metres minute volume increased by 13% and by 45%, and rate decreased by 10% and 30% respectively. In the abnormal lung stimulation, similar, but slightly less marked, changes occurred in all variables. These changes are of sufficient magnitude to require frequent observation of tidal volume and respiratory rate during aircraft ascent and descent.
Echocardiographic evaluation during weaning from mechanical ventilation
Schifelbain, Luciele Medianeira; Vieira, Silvia Regina Rios; Brauner, Janete Salles; Pacheco, Deise Mota; Naujorks, Alexandre Antonio
2011-01-01
INTRODUCTION: Echocardiographic, electrocardiographic and other cardiorespiratory variables can change during weaning from mechanical ventilation. OBJECTIVES: To analyze changes in cardiac function, using Doppler echocardiogram, in critical patients during weaning from mechanical ventilation, using two different weaning methods: pressure support ventilation and T‐tube; and comparing patient subgroups: success vs. failure in weaning. METHODS: Randomized crossover clinical trial including patients under mechanical ventilation for more than 48 h and considered ready for weaning. Cardiorespiratory variables, oxygenation, electrocardiogram and Doppler echocardiogram findings were analyzed at baseline and after 30 min in pressure support ventilation and T‐tube. Pressure support ventilation vs. T‐tube and weaning success vs. failure were compared using ANOVA and Student's t‐test. The level of significance was p<0.05. RESULTS: Twenty‐four adult patients were evaluated. Seven patients failed at the first weaning attempt. No echocardiographic or electrocardiographic differences were observed between pressure support ventilation and T‐tube. Weaning failure patients presented increases in left atrium, intraventricular septum thickness, posterior wall thickness and diameter of left ventricle and shorter isovolumetric relaxation time. Successfully weaned patients had higher levels of oxygenation. CONCLUSION: No differences were observed between Doppler echocardiographic variables and electrocardiographic and other cardiorespiratory variables during pressure support ventilation and T‐tube. However cardiac structures were smaller, isovolumetric relaxation time was larger, and oxygenation level was greater in successfully weaned patients. PMID:21437445
Impact of Room Ventilation Rates on Mouse Cage Ventilation and Microenvironment.
Reeb, Carolyn K.; Jones, Robert B.; Bearg, David W.; Bedigian, Hendrick; Paigen, Beverly
1997-01-01
To assess the impact of room ventilation on animal cage microenvironment, intracage ventilation rate, temperature, humidity, and concentrations of carbon dioxide and ammonia were monitored in nonpressurized, bonnet-topped mouse cages. Cages on the top, middle, and bottom rows of a mouse rack were monitored at room ventilation rates of 0, 5, 10, and 20 air changes/h (ACH). Ventilation inside the animal cage increased somewhat from 12.8 to 18.9 ACH as room ventilation rate in- creased from 0 to 20 ACH, but the differences were not statistically significant, and most of the increase occurred in cages in the top row nearest to the fresh air supply. Cages containing mice had ventilation rate between 10 and 15 ACH even when room ventilation was reduced to 0 ACH; this ventilation is a result of the thermal heat load of the mice. After 6 days of soiled bedding, intracage ammonia concentration was c 3 ppm at all room ventilation rates and was not affected by increasing room ventilation. Temperature inside cages did not change with increasing ventilation. Humidity inside cages significantly decreased with increasing ventilation, from 55% relative humidity at 5 ACH to 36% relative humidity at 20 ACH. Carbon dioxide concentration decreased from 2,500 ppm to 1,900 ppm when ventilation rate increased from 5 ACH to 10 ACH, but no further significant decrease was observed at 20 ACH. In conclusion, increasing the room ventilation rate higher than 5 ACH did not result in significant improvements in the cage microenvironment.
A new look at ocean ventilation time scales and their uncertainties
NASA Astrophysics Data System (ADS)
Fine, Rana A.; Peacock, Synte; Maltrud, Mathew E.; Bryan, Frank O.
2017-05-01
A suite of eddy-resolving ocean transient tracer model simulations are first compared to observations. Observational and model pCFC-11 ages agree quite well, with the eddy-resolving model adding detail. The CFC ages show that the thermocline is a barrier to interior ocean exchange with the atmosphere on time scales of 45 years, the measureable CFC transient, although there are exceptions. Next, model simulations are used to quantify effects on tracer ages of the spatial dependence of internal ocean tracer variability due to stirring from eddies and biases from nonstationarity of the atmospheric transient when there is mixing. These add to tracer age uncertainties and biases, which are large in frontal boundary regions, and small in subtropical gyre interiors. These uncertainties and biases are used to reinterpret observed temporal trends in tracer-derived ventilation time scales taken from observations more than a decade apart, and to assess whether interpretations of changes in tracer ages being due to changes in ocean ventilation hold water. For the southern hemisphere subtropical gyres, we infer that the rate of ocean ventilation 26-27.2 σθ increased between the mid-1990s and the decade of the 2000s. However, between the mid-1990s and the decade of the 2010s, there is no significant trend—perhaps except for South Atlantic. Observed age/AOU/ventilation changes are linked to a combination of natural cycles and climate change, and there is regional variability. Thus, for the future it is not clear how strong or steady in space and time ocean ventilation changes will be.
A new look at ocean ventilation time scales and their uncertainties
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fine, Rana A.; Peacock, Synte; Maltrud, Mathew E.
A suite of eddy-resolving ocean transient tracer model simulations are first compared to observations. Observational and model pCFC-11 ages agree quite well, with the eddy-resolving model adding detail. The CFC ages show that the thermocline is a barrier to interior ocean exchange with the atmosphere on time scales of 45 years, the measureable CFC transient, although there are exceptions. Next, model simulations are used to quantify effects on tracer ages of the spatial dependence of internal ocean tracer variability due to stirring from eddies and biases from nonstationarity of the atmospheric transient when there is mixing. These add to tracermore » age uncertainties and biases, which are large in frontal boundary regions, and small in subtropical gyre interiors. These uncertainties and biases are used to reinterpret observed temporal trends in tracer-derived ventilation time scales taken from observations more than a decade apart, and to assess whether interpretations of changes in tracer ages being due to changes in ocean ventilation hold water. For the southern hemisphere subtropical gyres, we infer that the rate of ocean ventilation 26–27.2 σ θ increased between the mid-1990s and the decade of the 2000s. However, between the mid-1990s and the decade of the 2010s, there is no significant trend—perhaps except for South Atlantic. Observed age/AOU/ventilation changes are linked to a combination of natural cycles and climate change, and there is regional variability. Thus, for the future it is not clear how strong or steady in space and time ocean ventilation changes will be.« less
A new look at ocean ventilation time scales and their uncertainties
Fine, Rana A.; Peacock, Synte; Maltrud, Mathew E.; ...
2017-03-17
A suite of eddy-resolving ocean transient tracer model simulations are first compared to observations. Observational and model pCFC-11 ages agree quite well, with the eddy-resolving model adding detail. The CFC ages show that the thermocline is a barrier to interior ocean exchange with the atmosphere on time scales of 45 years, the measureable CFC transient, although there are exceptions. Next, model simulations are used to quantify effects on tracer ages of the spatial dependence of internal ocean tracer variability due to stirring from eddies and biases from nonstationarity of the atmospheric transient when there is mixing. These add to tracermore » age uncertainties and biases, which are large in frontal boundary regions, and small in subtropical gyre interiors. These uncertainties and biases are used to reinterpret observed temporal trends in tracer-derived ventilation time scales taken from observations more than a decade apart, and to assess whether interpretations of changes in tracer ages being due to changes in ocean ventilation hold water. For the southern hemisphere subtropical gyres, we infer that the rate of ocean ventilation 26–27.2 σ θ increased between the mid-1990s and the decade of the 2000s. However, between the mid-1990s and the decade of the 2010s, there is no significant trend—perhaps except for South Atlantic. Observed age/AOU/ventilation changes are linked to a combination of natural cycles and climate change, and there is regional variability. Thus, for the future it is not clear how strong or steady in space and time ocean ventilation changes will be.« less
A taxonomy for mechanical ventilation: 10 fundamental maxims.
Chatburn, Robert L; El-Khatib, Mohamad; Mireles-Cabodevila, Eduardo
2014-11-01
The American Association for Respiratory Care has declared a benchmark for competency in mechanical ventilation that includes the ability to "apply to practice all ventilation modes currently available on all invasive and noninvasive mechanical ventilators." This level of competency presupposes the ability to identify, classify, compare, and contrast all modes of ventilation. Unfortunately, current educational paradigms do not supply the tools to achieve such goals. To fill this gap, we expand and refine a previously described taxonomy for classifying modes of ventilation and explain how it can be understood in terms of 10 fundamental constructs of ventilator technology: (1) defining a breath, (2) defining an assisted breath, (3) specifying the means of assisting breaths based on control variables specified by the equation of motion, (4) classifying breaths in terms of how inspiration is started and stopped, (5) identifying ventilator-initiated versus patient-initiated start and stop events, (6) defining spontaneous and mandatory breaths, (7) defining breath sequences (8), combining control variables and breath sequences into ventilatory patterns, (9) describing targeting schemes, and (10) constructing a formal taxonomy for modes of ventilation composed of control variable, breath sequence, and targeting schemes. Having established the theoretical basis of the taxonomy, we demonstrate a step-by-step procedure to classify any mode on any mechanical ventilator. Copyright © 2014 by Daedalus Enterprises.
Belenguer-Muncharaz, A; Albert-Rodrigo, L; Ferrandiz-Sellés, A; Cebrián-Graullera, G
2013-10-01
A comparison was made between invasive mechanical ventilation (IMV) and noninvasive positive pressure ventilation (NPPV) in haematological patients with acute respiratory failure. A retrospective observational study was made from 2001 to December 2011. A clinical-surgical intensive care unit (ICU) in a tertiary hospital. Patients with hematological malignancies suffering acute respiratory failure (ARF) and requiring mechanical ventilation in the form of either IMV or NPPV. Analysis of infection and organ failure rates, duration of mechanical ventilation and ICU and hospital stays, as well as ICU, hospital and mortality after 90 days. The same variables were analyzed in the comparison between NPPV success and failure. Forty-one patients were included, of which 35 required IMV and 6 NPPV. ICU mortality was higher in the IMV group (100% vs 37% in NPPV, P=.006). The intubation rate in NPPV was 40%. Compared with successful NPPV, failure in the NPPV group involved more complications, a longer duration of mechanical ventilation and ICU stay, and greater ICU and hospital mortality. Multivariate analysis of mortality in the NPPV group identified NPPV failure (OR 13 [95%CI 1.33-77.96], P=.008) and progression to acute respiratory distress syndrome (OR 10 [95%CI 1.95-89.22], P=.03) as prognostic factors. The use of NPPV reduced mortality compared with IMV. NPPV failure was associated with more complications. Copyright © 2012 Elsevier España, S.L. and SEMICYUC. All rights reserved.
ERIC Educational Resources Information Center
Schultz, Fred C.
2001-01-01
Reveals how seeking simplicity can help bring indoor air quality (IAQ) solutions to grade schools by balancing IAQ needs, cost, and energy. Issues involving ventilation rate requirements are reexamined, as are compliance with outside-air requirements, dealing with variable-air-volume air distribution regulators, and retrofitting issues involving…
Arcentales, Andrés; Giraldo, Beatriz F; Caminal, Pere; Benito, Salvador; Voss, Andreas
2011-01-01
Autonomic nervous system regulates the behavior of cardiac and respiratory systems. Its assessment during the ventilator weaning can provide information about physio-pathological imbalances. This work proposes a non linear analysis of the complexity of the heart rate variability (HRV) and breathing duration (T(Tot)) applying recurrence plot (RP) and their interaction joint recurrence plot (JRP). A total of 131 patients on weaning trials from mechanical ventilation were analyzed: 92 patients with successful weaning (group S) and 39 patients that failed to maintain spontaneous breathing (group F). The results show that parameters as determinism (DET), average diagonal line length (L), and entropy (ENTR), are statistically significant with RP for T(Tot) series, but not with HRV. When comparing the groups with JRP, all parameters have been relevant. In all cases, mean values of recurrence quantification analysis are higher in the group S than in the group F. The main differences between groups were found on the diagonal and vertical structures of the joint recurrence plot.
Pisaniello, D L; Gun, R T; Tkaczuk, M N; Hann, C; Crea, J
1993-09-01
As part of a two-year study of post-treatment residential exposure to the termiticide, aldrin, the building structural features of ten houses with crawl-space-type floors were assessed by an independent inspector. Building attributes recorded on a checklist included the age of the dwelling, room characteristics, floor details and the nature of subfloor ventilation. At the end of each inspection, the inspector, who was blinded to data on airborne aldrin concentrations, provided a rating of expected indoor air contamination. Several of the building attributes, including the age of the house, the area of exterior subfloor vents, as well as the inspector's rating, were significantly correlated with airborne aldrin values. No single building variable, however, was highly correlated with every measure of aldrin concentration over a 12-month period. The observed data are consistent with poor subfloor ventilation and a 'leaky' floor being important contributors to indoor air pollution. It is recommended that pest control companies advise householders about any obvious floor and ventilation deficiencies before soil treatment work is undertaken. Pesticide exposure (by analogy with geological radon exposure) may be reduced by sealing gaps in floors and/or by improving subfloor ventilation.
Community-based evaluation of laparoscopic versus open simple closure of perforated peptic ulcers.
Kuwabara, Kazuaki; Matsuda, Shinya; Fushimi, Kiyohide; Ishikawa, Koichi B; Horiguchi, Hiromasa; Fujimori, Kenji
2011-11-01
Several studies have advocated laparoscopic simple closure (LSC) as the treatment of choice for perforated peptic ulcer disease (PUD). However, there has been no comprehensive community-based evaluation of the advantages of using LSC over open simple closure (OSC). Using an administrative database, we evaluated LSC versus OSC for patients with perforated ulcers. From 6,334 patients with perforated ulcers, we identified 2,909 simple closure cases between 2006 and 2010. Study variables were demographics, mortality, co-morbidities, complications, ulcer location, surgical timing, blood transfusion, postoperative ventilation, operating room (OR) time, time to resumption of oral food intake, length of stay (LOS), and total charges. After matching patient baseline variables between OSC and LSC, we performed multivariate analyses to assess the impacts of LSC on mortality, complications, and ventilation administration. A total of 2,073 OSC cases and 836 LSC cases were identified in 670 hospitals. Younger age, duodenal ulcer, and pre-existing PUD were indicators for selection of LSC. Matching analysis indicated a correlation between LSC and lower mortality, less frequent postoperative and overall blood transfusion, shorter LOS, earlier return to oral intake, and longer OR time. There was no difference between OSC and LSC in complication rate or mortality. Longer OR time was correlated with a higher complication rate and the need for ventilation, the latter of which was independently associated with an increase in mortality. Because longer OR time was associated with more frequent complications and ventilation, surgeons should obtain the skills and strategies necessary to accomplish LSC without extending OR time improperly.
Kaub-Wittemer, Dagmar; Steinbüchel, Nicole von; Wasner, Maria; Laier-Groeneveld, Gerhard; Borasio, Gian Domenico
2003-10-01
Non-invasive ventilation (NIV) is an efficient palliative measure for symptoms of chronic hypoventilation in patients with amyotrophic lateral sclerosis (ALS), and can also lengthen survival. A subset of ALS patients undergoes tracheostomy ventilation (TV) for life prolongation. We investigated the quality of life (QOL) and psychosocial situation of 52 home ventilated ALS patients and their caregivers. The battery included sociodemographic, generic, and disease-specific variables, as well as the Profile of Mood States and the Munich Quality of Life Dimensions List. Data were compared between the NIV (n=32) and the TV (n=21) groups. Mean ventilation time was 14 months for NIV and 35 months for TV. Eighty-one percent of TV patients had been tracheotomized without informed consent. The data show a good overall QOL for both NIV and TV patients, but a very high burden of care for TV caregivers, 30% of whom rated their own QOL lower than their patient's QOL. Sexuality was an important issue. Thus, any assessment of QOL in a home palliative care situation should include the primary caregivers.
Lu, Chih-Cherng; Lin, Tso-Chou; Hsu, Che-Hao; Yu, Mu-Hsien; Chen, Ta-Liang; Chen, Ruei-Ming; Ku, Chih-Hung; Ho, Shung-Tai
2012-09-01
Under a constant inspired concentration, the uptake of a volatile anesthetic into the arterial blood should mainly be governed by alveolar ventilation, according to the assumption that the patient's cardiac output remains stable during anesthesia. We investigated whether ventilation volume affects the rate of desflurane uptake by examining arterial blood concentrations. Thirty female patients were randomly allocated into the following three groups: hyperventilation, normal ventilation and hypoventilation. Hemodynamic variables were measured using a Finometer, inspiratory and end-tidal concentrations of desflurane were measured by infrared analysis, and the desflurane concentration in the arterial blood (Ades) was analyzed by gas chromatography. During the first 10 minutes after the administration of desflurane, the Ades was highest in the hyperventilation group, and this value was significantly different from those obtained for the normal and hypoventilation groups. In addition, hyperventilation significantly increased the slope of Ades-over-time during the first 5 minutes compared with patients experiencing normal ventilation and hypoventilation, but there were no differences in these slopes during the periods from 5-10, 10-20 and 20-40 minutes after the administration of desflurane. This finding indicates that there were no differences in desflurane uptake between the three groups after the first 5 minutes within desflurane administration. Hyperventilation accelerated the rate of the rise in Ades following desflurane administration, which was time-dependent with respect to different alveolar ventilations levels.
Lu, Chih-Cherng; Lin, Tso-Chou; Hsu, Che-Hao; Yu, Mu-Hsien; Chen, Ta-Liang; Chen, Ruei-Ming; Ku, Chih-Hung; Ho, Shung-Tai
2012-01-01
OBJECTIVES: Under a constant inspired concentration, the uptake of a volatile anesthetic into the arterial blood should mainly be governed by alveolar ventilation, according to the assumption that the patient's cardiac output remains stable during anesthesia. We investigated whether ventilation volume affects the rate of desflurane uptake by examining arterial blood concentrations. METHOD: Thirty female patients were randomly allocated into the following three groups: hyperventilation, normal ventilation and hypoventilation. Hemodynamic variables were measured using a Finometer, inspiratory and end-tidal concentrations of desflurane were measured by infrared analysis, and the desflurane concentration in the arterial blood (Ades) was analyzed by gas chromatography. RESULTS: During the first 10 minutes after the administration of desflurane, the Ades was highest in the hyperventilation group, and this value was significantly different from those obtained for the normal and hypoventilation groups. In addition, hyperventilation significantly increased the slope of Ades-over-time during the first 5 minutes compared with patients experiencing normal ventilation and hypoventilation, but there were no differences in these slopes during the periods from 5-10, 10-20 and 20-40 minutes after the administration of desflurane. This finding indicates that there were no differences in desflurane uptake between the three groups after the first 5 minutes within desflurane administration. CONCLUSIONS: Hyperventilation accelerated the rate of the rise in Ades following desflurane administration, which was time-dependent with respect to different alveolar ventilations levels. PMID:23018299
Natural ventilation for the prevention of airborne contagion.
Escombe, A Roderick; Oeser, Clarissa C; Gilman, Robert H; Navincopa, Marcos; Ticona, Eduardo; Pan, William; Martínez, Carlos; Chacaltana, Jesus; Rodríguez, Richard; Moore, David A J; Friedland, Jon S; Evans, Carlton A
2007-02-01
Institutional transmission of airborne infections such as tuberculosis (TB) is an important public health problem, especially in resource-limited settings where protective measures such as negative-pressure isolation rooms are difficult to implement. Natural ventilation may offer a low-cost alternative. Our objective was to investigate the rates, determinants, and effects of natural ventilation in health care settings. The study was carried out in eight hospitals in Lima, Peru; five were hospitals of "old-fashioned" design built pre-1950, and three of "modern" design, built 1970-1990. In these hospitals 70 naturally ventilated clinical rooms where infectious patients are likely to be encountered were studied. These included respiratory isolation rooms, TB wards, respiratory wards, general medical wards, outpatient consulting rooms, waiting rooms, and emergency departments. These rooms were compared with 12 mechanically ventilated negative-pressure respiratory isolation rooms built post-2000. Ventilation was measured using a carbon dioxide tracer gas technique in 368 experiments. Architectural and environmental variables were measured. For each experiment, infection risk was estimated for TB exposure using the Wells-Riley model of airborne infection. We found that opening windows and doors provided median ventilation of 28 air changes/hour (ACH), more than double that of mechanically ventilated negative-pressure rooms ventilated at the 12 ACH recommended for high-risk areas, and 18 times that with windows and doors closed (p < 0.001). Facilities built more than 50 years ago, characterised by large windows and high ceilings, had greater ventilation than modern naturally ventilated rooms (40 versus 17 ACH; p < 0.001). Even within the lowest quartile of wind speeds, natural ventilation exceeded mechanical (p < 0.001). The Wells-Riley airborne infection model predicted that in mechanically ventilated rooms 39% of susceptible individuals would become infected following 24 h of exposure to untreated TB patients of infectiousness characterised in a well-documented outbreak. This infection rate compared with 33% in modern and 11% in pre-1950 naturally ventilated facilities with windows and doors open. Opening windows and doors maximises natural ventilation so that the risk of airborne contagion is much lower than with costly, maintenance-requiring mechanical ventilation systems. Old-fashioned clinical areas with high ceilings and large windows provide greatest protection. Natural ventilation costs little and is maintenance free, and is particularly suited to limited-resource settings and tropical climates, where the burden of TB and institutional TB transmission is highest. In settings where respiratory isolation is difficult and climate permits, windows and doors should be opened to reduce the risk of airborne contagion.
Metabolically Derived Human Ventilation Rates: A Revised ...
EPA announced the availability of the final report, Metabolically Derived Human Ventilation Rates: A Revised Approach Based Upon Oxygen Consumption Rates. This report provides a revised approach for calculating an individual's ventilation rate directly from their oxygen consumption rate. This approach will be used to update the ventilation rate information in the Exposure Factors Handbook, which serve as a resources for exposure assessors for calculating inhalation and other exposures. In this report, EPA presents a revised approach in which ventilation rate is calculated directly from an individual's oxygen consumption rate.
Reyes, Catalina; Milsom, William K
2010-01-01
Endogenous circadian and circannual rhythms may exist in the metabolism, ventilation, and breathing pattern of turtles that could further prolong dive times during daily and seasonal periods of reduced activity. To test this hypothesis, turtles were held under seasonal or constant environmental conditions over a 1-yr period, and in each season, V(O)(2) and respiratory variables were measured in all animals under both the prevailing seasonal conditions and the constant conditions for 24 h. Endogenous circadian and circannual rhythms in metabolism and ventilation occurred independent of ambient temperature, photoperiod, and activity, although long-term entrainment to daily and seasonal changes in temperature and photoperiod were required for them to be expressed. Metabolism and ventilation were always higher during the photophase, and the day-night difference was greater at any given temperature when the photoperiod was provided. When corrected for temperature, turtles had elevated metabolic and ventilation rates in the fall and spring (corresponding to the reproductive seasons) and suppressed metabolism and ventilation during winter. The strength of the circadian rhythm varied seasonally, with proportionately larger day-night differences in colder seasons. Daily and seasonal cycles in ventilation largely followed metabolism, although daily and seasonal changes did occur in the breathing pattern independent of levels of total ventilation. These endogenous circadian and circannual changes in metabolism, ventilation, and breathing pattern prolonged dive times at night and in winter and may serve to reduce the costs of breathing and transport and risk of predation.
NASA Astrophysics Data System (ADS)
Rodes, C. E.; Chillrud, S. N.; Haskell, W. L.; Intille, S. S.; Albinali, F.; Rosenberger, M. E.
2012-09-01
BackgroundMetabolic functions typically increase with human activity, but optimal methods to characterize activity levels for real-time predictions of ventilation volume (l min-1) during exposure assessments have not been available. Could tiny, triaxial accelerometers be incorporated into personal level monitors to define periods of acceptable wearing compliance, and allow the exposures (μg m-3) to be extended to potential doses in μg min-1 kg-1 of body weight? ObjectivesIn a pilot effort, we tested: 1) whether appropriately-processed accelerometer data could be utilized to predict compliance and in linear regressions to predict ventilation volumes in real-time as an on-board component of personal level exposure sensor systems, and 2) whether locating the exposure monitors on the chest in the breathing zone, provided comparable accelerometric data to other locations more typically utilized (waist, thigh, wrist, etc.). MethodsPrototype exposure monitors from RTI International and Columbia University were worn on the chest by a pilot cohort of adults while conducting an array of scripted activities (all <10 METS), spanning common recumbent, sedentary, and ambulatory activity categories. Referee Wocket accelerometers that were placed at various body locations allowed comparison with the chest-located exposure sensor accelerometers. An Oxycon Mobile mask was used to measure oral-nasal ventilation volumes in-situ. For the subset of participants with complete data (n = 22), linear regressions were constructed (processed accelerometric variable versus ventilation rate) for each participant and exposure monitor type, and Pearson correlations computed to compare across scenarios. ResultsTriaxial accelerometer data were demonstrated to be adequately sensitive indicators for predicting exposure monitor wearing compliance. Strong linear correlations (R values from 0.77 to 0.99) were observed for all participants for both exposure sensor accelerometer variables against ventilation volume for recumbent, sedentary, and ambulatory activities with MET values ˜<6. The RTI monitors mean R value of 0.91 was slightly higher than the Columbia monitors mean of 0.86 due to utilizing a 20 Hz data rate instead of a slower 1 Hz rate. A nominal mean regression slope was computed for the RTI system across participants and showed a modest RSD of +/-36.6%. Comparison of the correlation values of the exposure monitors with the Wocket accelerometers at various body locations showed statistically identical regressions for all sensors at alternate hip, ankle, upper arm, thigh, and pocket locations, but not for the Wocket accelerometer located at the dominant side wrist location (R = 0.57; p = 0.016). ConclusionsEven with a modest number of adult volunteers, the consistency and linearity of regression slopes for all subjects were very good with excellent within-person Pearson correlations for the accelerometer versus ventilation volume data. Computing accelerometric standard deviations allowed good sensitivity for compliance assessments even for sedentary activities. These pilot findings supported the hypothesis that a common linear regression is likely to be usable for a wider range of adults to predict ventilation volumes from accelerometry data over a range of low to moderate energy level activities. The predicted volumes would then allow real-time estimates of potential dose, enabling more robust panel studies. The poorer correlation in predicting ventilation rate for an accelerometer located on the wrist suggested that this location should not be considered for predictions of ventilation volume.
Biomarker kinetics in the prediction of VAP diagnosis: results from the BioVAP study.
Póvoa, Pedro; Martin-Loeches, Ignacio; Ramirez, Paula; Bos, Lieuwe D; Esperatti, Mariano; Silvestre, Joana; Gili, Gisela; Goma, Gema; Berlanga, Eugenio; Espasa, Mateu; Gonçalves, Elsa; Torres, Antoni; Artigas, Antonio
2016-12-01
Prediction of diagnosis of ventilator-associated pneumonia (VAP) remains difficult. Our aim was to assess the value of biomarker kinetics in VAP prediction. We performed a prospective, multicenter, observational study to evaluate predictive accuracy of biomarker kinetics, namely C-reactive protein (CRP), procalcitonin (PCT), mid-region fragment of pro-adrenomedullin (MR-proADM), for VAP management in 211 patients receiving mechanical ventilation for >72 h. For the present analysis, we assessed all (N = 138) mechanically ventilated patients without an infection at admission. The kinetics of each variable, from day 1 to day 6 of mechanical ventilation, was assessed with each variable's slopes (rate of biomarker change per day), highest level and maximum amplitude of variation (Δ (max)). A total of 35 patients (25.4 %) developed a VAP and were compared with 70 non-infected controls (50.7 %). We excluded 33 patients (23.9 %) who developed a non-VAP nosocomial infection. Among the studied biomarkers, CRP and CRP ratio showed the best performance in VAP prediction. The slope of CRP change over time (adjusted odds ratio [aOR] 1.624, confidence interval [CI]95% [1.206, 2.189], p = 0.001), the highest CRP ratio concentration (aOR 1.202, CI95% [1.061, 1.363], p = 0.004) and Δ (max) CRP (aOR 1.139, CI95% [1.039, 1.248], p = 0.006), during the first 6 days of mechanical ventilation, were all significantly associated with VAP development. Both PCT and MR-proADM showed a poor predictive performance as well as temperature and white cell count. Our results suggest that in patients under mechanical ventilation, daily CRP monitoring was useful in VAP prediction. Trial registration NCT02078999.
Miller, Melissa A; Arndt, Jennifer L; Konkle, Mark A; Chenoweth, Carol E; Iwashyna, Theodore J; Flaherty, Kevin R; Hyzy, Robert C
2011-06-01
The aim of this study was to determine whether the use of a polyurethane-cuffed endotracheal tube would result in a decrease in ventilator-associated pneumonia rate. We replaced conventional endotracheal tube with a polyurethane-cuff endotracheal tube (Microcuff, Kimberly-Clark Corporation, Rosewell, Ga) in all adult mechanically ventilated patients throughout our large academic hospital from July 2007 to June 2008. We retrospectively compared the rates of ventilator-associated pneumonia before, during, and after the intervention year by interrupted time-series analysis. Ventilator-associated pneumonia rates decreased from 5.3 per 1000 ventilator days before the use of the polyurethane-cuffed endotracheal tube to 2.8 per 1000 ventilator days during the intervention year (P = .0138). During the first 3 months after return to conventional tubes, the rate of ventilator-associated pneumonia was 3.5/1000 ventilator days. Use of the polyurethane-cuffed endotracheal tube was associated with an incidence risk ratio of ventilator-associated pneumonia of 0.572 (95% confidence interval, 0.340-0.963). In statistical regression analysis controlling for other possible alterations in the hospital environment, as measured by rate of tracheostomy-ventilator-associated pneumonia, the incidence risk ratio of ventilator-associated pneumonia in patients intubated with polyurethane-cuffed endotracheal tube was 0.565 (P = .032; 95% confidence interval, 0.335-0.953). Use of a polyurethane-cuffed endotracheal tube was associated with a significant decrease in the rate of ventilator-associated pneumonia in our study. Copyright © 2011 Elsevier Inc. All rights reserved.
Winter ventilation rates at primary schools: comparison between Portugal and Finland.
Canha, N; Almeida, S M; Freitas, M C; Täubel, M; Hänninen, O
2013-01-01
This study focused on examination of ventilation rates in classrooms with two different types of ventilation systems: natural and mechanical. Carbon dioxide (CO2) measurements were conducted in primary schools of Portugal characterized by natural ventilation and compared to Finland where mechanical ventilation is the norm. The winter period was selected since this season exerts a great influence in naturally ventilated classrooms, where opening of windows and doors occurs due to outdoor atmospheric conditions. The ventilation rates were calculated by monitoring CO2 concentrations generated by the occupants (used as a tracer gas) and application of the buildup phase method. A comparison between both countries' results was conducted with respect to ventilation rates and how these levels corresponded to national regulatory standards. Finnish primary schools (n = 2) registered a mean ventilation rate of 13.3 L/s per person, which is higher than the recommended ventilation standards. However, the Finnish classroom that presented the lowest ventilation rate (7.2 L/s per person) displayed short-term CO2 levels above 1200 ppm, which is the threshold limit value (TLV) recommended by national guidelines. The Portuguese classrooms (n = 2) showed low ventilation rates with mean values of 2.4 L/s per person, which is markedly lower than the minimum recommended value of 7 L/s per person as defined by ASHRAE and 20% less than the REHVA minimum of 3 L/s per person. Carbon dioxide levels of 1000 ppm, close to the TLV of 1200 ppm, were also reached in both Portuguese classrooms studied. The situation in Portugal indicates a potentially serious indoor air quality problem and strengthens the need for intervention to improve ventilation rates in naturally ventilated classrooms.
Han, Lin; Li, Ji P; Sit, Janet W H; Chung, Loretta; Jiao, Zuo Y; Ma, Wei G
2010-04-01
To examine the effects of music intervention on the physiological stress response and the anxiety level among mechanically ventilated patients in intensive care unit. Despite the fact that previous studies have found music interventions to be effective in stress and anxiety reduction, effects of music on the Chinese population are inconclusive and warranted systematic study to evaluate its effect fully for a different Asian culture. A randomised placebo-controlled trial. A total of 137 patients receiving mechanical ventilation were randomly assigned to either music listening group, headphone group or control group. Outcome measures included the Chinese version of Spielberger State-Trait Anxiety Scale and physiological parameters (heart rate, respiratory rate, saturation of oxygen and blood pressure). Comparison of mean differences (pretest score-posttest score) showed significant differences in heart rate, respiratory rate, systolic blood pressure and diastolic blood pressure as well as the Chinese version of Spielberger State-Trait Anxiety Scale, but not in SaO(2) among the three groups (ranging from p < 0.001 to p = 0.007), of which greater mean differences were found in music listening group. A significant reduction in physiological stress response (heart rate and respiratory rate) over time was found in music listening group (p < 0.001 for both variables) and a significant increase in heart rate and respiratory rate over time in control group (p < 0.001 and p = 0.032), with no significant change over time in headphone group. Within group pretest-posttest comparison of the Chinese version of Spielberger State-Trait Anxiety Scale demonstrated a significant reduction in anxiety for the music listening group (p < 0.001) and headphone group (p < 0.001) but not the control group. Our findings confirm that short-term therapeutic effects of music listening results in substantial reduction in physiological stress responses arising from anxiety in mechanically ventilated patients. Music as a non-pharmacological nursing intervention can be used as complementary adjunct in the care of patients with low-energy states who tire easily, such as those requiring mechanical ventilator support.
Nin, Nicolás; Lombardi, Raúl; Frutos-Vivar, Fernando; Esteban, Andrés; Lorente, José A; Ferguson, Niall D; Hurtado, Javier; Apezteguia, Carlos; Brochard, Laurent; Schortgen, Fréderique; Raymondos, Konstantinos; Tomicic, Vinko; Soto, Luis; González, Marco; Nightingale, Peter; Abroug, Fekri; Pelosi, Paolo; Arabi, Yaseen; Moreno, Rui; Anzueto, Antonio
2010-08-01
Emerging evidence suggests that minor changes in serum creatinine concentrations are associated with increased hospital mortality rates. However, whether serum creatinine concentration (SCr) on admission and its change are associated with an increased mortality rate in mechanically ventilated patients is not known. We have conducted an international, prospective, observational cohort study enrolling adult intensive care unit patients under mechanical ventilation (MV). Recursive partitioning was used to determine the values of SCr at the start of MV (SCr0) and the change in SCr ([DeltaSCr] defined as the maximal difference between the value at start of MV [day 0] and the value on MV day 2 at 8:00 am) that best discriminate mortality. In-hospital mortality, adjusted by a proportional hazards model, was the primary outcome variable. A total of 2,807 patients were included; median age was 59 years and median Simplified Acute Physiology Score II was 44. All-cause in-hospital mortality was 44%. The variable that best discriminated outcome was a SCr0 greater than 1.40 mg/dL (mortality, 57% vs. 36% for patients with SCr0
The effect of preexisting respiratory co-morbidities on burn outcomes☆
Knowlin, Laquanda T.; Stanford, Lindsay B.; Cairns, Bruce A.; Charles, Anthony G.
2018-01-01
Introduction Burns cause physiologic changes in multiple organ systems in the body. Burn mortality is usually attributable to pulmonary complications, which can occur in up to 41% of patients admitted to the hospital after burn. Patients with preexisting comorbidities such as chronic lung diseases may be more susceptible. We therefore sought to examine the impact of preexisting respiratory disease on burn outcomes. Methods A retrospective analysis of patients admitted to a regional burn center from 2002–2012. Independent variables analyzed included basic demographics, burn mechanism, presence of inhalation injury, TBSA, pre-existing comorbidities, smoker status, length of hospital stay, and days of mechanical ventilation. Bivariate analysis was performed and Cox regression modeling using significant variables was utilized to estimate hazard of progression to mechanical ventilation and mortality. Results There were a total of 7640 patients over the study period. Overall survival rate was 96%. 8% (n=672) had a preexisting respiratory disease. Chronic lung disease patients had a higher mortality rate (7%) compared to those without lung disease (4%, p<0.01). The adjusted Cox regression model to estimate the hazard of progression to mechanical ventilation in patients with respiratory disease was 21% higher compared to those without respiratory disease (HR=1.21, 95% CI=1.01–1.44). The hazard of progression to mortality is 56% higher (HR=1.56, 95% CI=1.10–2.19) for patients with pre-existing respiratory disease compared to those without respiratory disease after controlling for patient demographics and injury characteristics. Conclusion Preexisting chronic respiratory disease significantly increases the hazard of progression to mechanical ventilation and mortality in patients following burn. Given the increasing number of Americans with chronic respiratory diseases, there will likely be a greater number of individuals at risk for worse outcomes following burn. PMID:28341260
The effect of preexisting respiratory co-morbidities on burn outcomes.
Knowlin, Laquanda T; Stanford, Lindsay B; Cairns, Bruce A; Charles, Anthony G
2017-03-01
Burns cause physiologic changes in multiple organ systems in the body. Burn mortality is usually attributable to pulmonary complications, which can occur in up to 41% of patients admitted to the hospital after burn. Patients with preexisting comorbidities such as chronic lung diseases may be more susceptible. We therefore sought to examine the impact of preexisting respiratory disease on burn outcomes. A retrospective analysis of patients admitted to a regional burn center from 2002-2012. Independent variables analyzed included basic demographics, burn mechanism, presence of inhalation injury, TBSA, pre-existing comorbidities, smoker status, length of hospital stay, and days of mechanical ventilation. Bivariate analysis was performed and Cox regression modeling using significant variables was utilized to estimate hazard of progression to mechanical ventilation and mortality. There were a total of 7640 patients over the study period. Overall survival rate was 96%. 8% (n=672) had a preexisting respiratory disease. Chronic lung disease patients had a higher mortality rate (7%) compared to those without lung disease (4%, p<0.01). The adjusted Cox regression model to estimate the hazard of progression to mechanical ventilation in patients with respiratory disease was 21% higher compared to those without respiratory disease (HR=1.21, 95% CI=1.01-1.44). The hazard of progression to mortality is 56% higher (HR=1.56, 95% CI=1.10-2.19) for patients with pre-existing respiratory disease compared to those without respiratory disease after controlling for patient demographics and injury characteristics. Preexisting chronic respiratory disease significantly increases the hazard of progression to mechanical ventilation and mortality in patients following burn. Given the increasing number of Americans with chronic respiratory diseases, there will likely be a greater number of individuals at risk for worse outcomes following burn. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Variability of Tidal Volume in Patient-Triggered Mechanical Ventilation in ARDS.
Perinel-Ragey, Sophie; Baboi, Loredana; Guérin, Claude
2017-11-01
Limiting tidal volume (V T ) in patients with ARDS may not be achieved once patient-triggered breaths occur. Furthermore, ICU ventilators offer numerous patient-triggered modes that work differently across brands. We systematically investigated, using a bench model, the effect of patient-triggered modes on the size and variability of V T at different breathing frequencies (f), patient effort, and ARDS severity. We used a V500 Infinity ICU ventilator connected to an ASL 5000 lung model whose compliance was mimicking mild, moderate, and severe ARDS. Thirteen patient-triggered modes were tested, falling into 3 categories, namely volume control ventilation with mandatory minute ventilation; pressure control ventilation, including airway pressure release ventilation (APRV); and pressure support ventilation. Two levels of f and effort were tested for each ARDS severity in each mode. Median (first-third quartiles) V T was compared across modes using non-parametric tests. The probability of V T > 6 mL/kg ideal body weight was assessed by binomial regression and expressed as the odds ratio (OR) with 95% CI. V T variability was measured from the coefficient of variation. V T distribution over all f, effort, and ARDS categories significantly differed across modes ( P < .001, Kruskal-Wallis test). V T was significantly greater with pressure support (OR 420 mL, 95% CI 332-527 mL) than with any other mode except for variable pressure support level. Risk for V T to be > 6 mL/kg was significantly increased with spontaneous breaths patient-triggered by pressure support (OR 19.36, 95% CI 12.37-30.65) and significantly reduced in APRV (OR 0.44, 95% CI 0.26-0.72) and pressure support with guaranteed volume mode. The risk increased with increasing effort and decreasing f. Coefficient of variation of V T was greater for low f and volume control-mandatory minute ventilation and pressure control modes. APRV had the greatest within-mode variability. Risk of V T > 6 mL/kg was significantly reduced in APRV and pressure support with guaranteed volume mode. APRV had the highest variability. Pressure support with guaranteed volume could be tested in patients with ARDS. Copyright © 2017 by Daedalus Enterprises.
Physiological and biomechanical responses while running with and without a stroller.
Smith, J D; Smith, J D; Kinser, K B; Dugan, E; Reed, M
2005-09-01
This study examined the effects of pushing a jogging stroller on biomechanical and physiological variables. The hypothesis was that running with a stroller for 30 minutes would shorten stride length and increase physiological indices of exercise. this was a repeated measures design. participants were recruited from road races in the Dallas/Fort Worth, TX area. Graded exercise tests were performed in a laboratory setting, field tests were performed on a 400 m all-weather outdoor track. 5 males and 5 females were assessed. participants performed a graded exercise test and 2 field tests. The 1st field test involved running at 75% VO2max for 30 minutes without a stroller and the 2nd involved running at the same speed with the stroller. VO2, stride length, heart rate, lactate, ventilation, and RPE were evaluated. No differences for VO2 or stride length were evident. Heart rate (p=0.0001), lactate concentration (p=0.025), ventilation (p=0.009), and RPE (p=0.002) increased from 10 to 30 minutes while running with the stroller. Heart rate (p=0.002), lactate concentration (p=0.0001), ventilation (p=0.006), and RPE (p=0.001) were significantly higher while running with the stroller after 30 minutes compared to running without it. These results indicate that pushing a stroller affects some indices of exercise intensity while running. Gait does not change. These data do not support an association between stroller use during running and an increase risk of orthopedic injury. Further studies should examine these variables at lower intensities that are run by most recreational joggers.
Cardiopulmonary function and oxygen delivery during total liquid ventilation.
Tsagogiorgas, Charalambos; Alb, Markus; Herrmann, Peter; Quintel, Michael; Meinhardt, Juergen P
2011-10-01
Total liquid ventilation (TLV) with perfluorocarbons has shown to improve cardiopulmonary function in the injured and immature lung; however there remains controversy over the normal lung. Hemodynamic effects of TLV in the normal lung currently remain undetermined. This study compared changes in cardiopulmonary and circulatory function caused by either liquid or gas tidal volume ventilation. In a prospective, controlled study, 12 non-injured anesthetized, adult New Zealand rabbits were primarily conventionally gas-ventilated (CGV). After instrumentation for continuous recording of arterial (AP), central venous (CVP), left artrial (LAP), pulmonary arterial pressures (PAP), and cardiac output (CO) animals were randomized into (1) CGV group and (2) TLV group. In the TLV group partial liquid ventilation was initiated with instillation of perfluoroctylbromide (12 ml/kg). After 15 min, TLV was established for 3 hr applying a volume-controlled, pressure-limited, time-cycled ventilation mode using a double-piston configured TLV. Controls (CGV) remained gas-ventilated throughout the experiment. During TLV, heart rate, CO, PAP, MAP, CVP, and LAP as well as derived hemodynamic variables, arterial and mixed venous blood gases, oxygen delivery, PVR, and SVR did not differ significantly compared to CGV. Liquid tidal volumes suitable for long-term TLV in non-injured rabbits do not significantly impair CO, blood pressure, and oxygen dynamics when compared to CGV. Copyright © 2011 Wiley-Liss, Inc.
Kern, Delphine; Larcher, Claire; Basset, Bertrand; Alacoque, Xavier; Fesseau, Rose; Samii, Kamran; Minville, Vincent; Fourcade, Olivier
2012-08-01
We measured the time it takes to reach the desired inspired anesthetic concentration using the Primus (Drägerwerk, AG, Lübeck, Germany) and the Avance (GE Datex-Ohmeda, Munich, Germany) anesthesia machines with toddler and newborn ventilation settings. The time to reach 95% of inspired target sevoflurane concentration was measured during wash-in from 0 to 6 vol% sevoflurane and during wash-out from 6 to 0 vol% with fresh gas flows equal to 1 and 2 times the minute ventilation. The Avance was faster than the Primus (65 seconds [95% confidence interval (CI): 55 to 78] vs 310 seconds [95% CI: 261 to 359]) at 1.5 L/min fresh gas flow, tidal volume of 50 mL, and 30 breaths/min. Times were shorter by the same magnitude at higher fresh gas flows and higher minute ventilation rates. The effect of doubling fresh gas flow was variable and less than expected. The Primus is slower during newborn than toddler ventilation, whereas the Avance's response time was the same for newborn and toddler ventilation. Our data confirm that the time to reach the target-inspired anesthetic concentration depends on breathing circuit volume, fresh gas flow, and minute ventilation.
Ventilator-associated pneumonia in surgical emergency intensive care unit.
Ertugrul, Bulent M; Yildirim, Ayse; Ay, Pinar; Oncu, Serkan; Cagatay, Atahan; Cakar, Nahit; Ertekin, Cemalettin; Ozsut, Halit; Eraksoy, Haluk; Calangu, Semra
2006-01-01
To investigate the incidence, risk factors and the etiology of ventilator-associated pneumonia (VAP) in surgical emergency intensive care unit (ICU) patients. We conducted this prospective cohort study in the surgical emergency ICU of Istanbul Medical Faculty between December 1999 and May 2001. We included 100 mechanically ventilated patients in this study. We diagnosed VAP according to the current diagnostic criteria. We identified the etiology of VAP cases by both quantitative cultures of endotracheal aspiration and blood cultures. To analyze the predisposing factors for the development of VAP, we recorded the following variables: age, gender, acute physiology and chronic health evaluation (APACHE) II score, Glasgow coma scale (GCS), sequential organ failure assessment (SOFA) score, serum albumin level, duration of mechanical ventilation (MV) prior to the development of VAP, and underlying diseases. We determined the VAP incidence rate as 28%. We found the APACHE II score and the duration of MV to be statistically significant variables for the development of VAP. There were no significant differences regarding age, gender, GCS, SOFA score, albumin level, or underlying diseases for the development of VAP. The isolated bacteria among VAP cases were as follows: Staphylococcus aureus (n=12, 43%), Acinetobacter spp. (n=6, 21%), coagulase-negative Staphylococci (n=4, 15%), Pseudomonas aeruginosa (n=3, 10.7%) and Klebsiella pneumoniae (n=3, 10.7%). Ventilator-associated pneumonia is a common infection, and certain interventions might affect the incidence of VAP. The ICU clinicians should be aware of the risk factors for VAP, which could prove useful in identifying patients at high risk for VAP, and modifying patient care to minimize the risk of VAP.
This work summarizes advancements made that allow for better estimation of resting metabolic rate (RMR) and subsequent estimation of ventilation rates (i.e., total ventilation (VE) and alveolar ventilation (VA)) for individuals of both genders and all ages. ...
Matthay, Michael A; Brower, Roy G; Carson, Shannon; Douglas, Ivor S; Eisner, Mark; Hite, Duncan; Holets, Steven; Kallet, Richard H; Liu, Kathleen D; MacIntyre, Neil; Moss, Marc; Schoenfeld, David; Steingrub, Jay; Thompson, B Taylor
2011-09-01
β₂-Adrenergic receptor agonists accelerate resolution of pulmonary edema in experimental and clinical studies. This clinical trial was designed to test the hypothesis that an aerosolized β₂-agonist, albuterol, would improve clinical outcomes in patients with acute lung injury (ALI). We conducted a multicenter, randomized, placebo-controlled clinical trial in which 282 patients with ALI receiving mechanical ventilation were randomized to receive aerosolized albuterol (5 mg) or saline placebo every 4 hours for up to 10 days. The primary outcome variable for the trial was ventilator-free days. Ventilator-free days were not significantly different between the albuterol and placebo groups (means of 14.4 and 16.6 d, respectively; 95% confidence interval for the difference, -4.7 to 0.3 d; P = 0.087). Rates of death before hospital discharge were not significantly different between the albuterol and placebo groups (23.0 and 17.7%, respectively; 95%confidence interval for the difference,-4.0 to 14.7%;P = 0.30). In the subset of patients with shock before randomization, the number of ventilator-free days was lower with albuterol, although mortality was not different. Overall, heart rates were significantly higher in the albuterol group by approximately 4 beats/minute in the first 2 days after randomization, but rates of new atrial fibrillation (10% in both groups) and other cardiac dysrhythmias were not significantly different. These results suggest that aerosolized albuterol does not improve clinical outcomes in patients with ALI. Routine use of β₂-agonist therapy in mechanically ventilated patients with ALI cannot be recommended. Clinical trial registered with www.clinicaltrials.gov (NCT 00434993).
Conservative fluid management prevents age-associated ventilator induced mortality.
Herbert, Joseph A; Valentine, Michael S; Saravanan, Nivi; Schneck, Matthew B; Pidaparti, Ramana; Fowler, Alpha A; Reynolds, Angela M; Heise, Rebecca L
2016-08-01
Approximately 800 thousand patients require mechanical ventilation in the United States annually with an in-hospital mortality rate of over 30%. The majority of patients requiring mechanical ventilation are over the age of 65 and advanced age is known to increase the severity of ventilator-induced lung injury (VILI) and in-hospital mortality rates. However, the mechanisms which predispose aging ventilator patients to increased mortality rates are not fully understood. Ventilation with conservative fluid management decreases mortality rates in acute respiratory distress patients, but to date there has been no investigation of the effect of conservative fluid management on VILI and ventilator associated mortality rates. We hypothesized that age-associated increases in susceptibility and incidence of pulmonary edema strongly promote age-related increases in ventilator associated mortality. 2month old and 20month old male C57BL6 mice were mechanically ventilated with either high tidal volume (HVT) or low tidal volume (LVT) for up to 4h with either liberal or conservative fluid support. During ventilation, lung compliance, total lung capacity, and hysteresis curves were quantified. Following ventilation, bronchoalveolar lavage fluid was analyzed for total protein content and inflammatory cell infiltration. Wet to dry ratios were used to directly measure edema in excised lungs. Lung histology was performed to quantify alveolar barrier damage/destruction. Age matched non-ventilated mice were used as controls. At 4h, both advanced age and HVT ventilation significantly increased markers of inflammation and injury, degraded pulmonary mechanics, and decreased survival rates. Conservative fluid support significantly diminished pulmonary edema and improved pulmonary mechanics by 1h in advanced age HVT subjects. In 4h ventilations, conservative fluid support significantly diminished pulmonary edema, improved lung mechanics, and resulted in significantly lower mortality rates in older subjects. Our study demonstrates that conservative fluid alone can attenuate the age associated increase in ventilator associated mortality. Copyright © 2016 Elsevier Inc. All rights reserved.
Conservative Fluid Management Prevents Age-Associated Ventilator Induced Mortality
Herbert, Joseph A.; Valentine, Michael S.; Saravanan, Nivi; Schneck, Matthew B.; Pidaparti, Ramana; Fowler, Alpha A.; Reynolds, Angela M.; Heise, Rebecca L.
2017-01-01
Background Approximately 800 thousand patients require mechanical ventilation in the United States annually with an in-hospital mortality rate of over 30%. The majority of patients requiring mechanical ventilation are over the age of 65 and advanced age is known to increase the severity of ventilator-induced lung injury (VILI) and in-hosptial mortality rates. However, the mechanisms which predispose aging ventilator patients to increased mortality rates are not fully understood. Ventilation with conservative fluid management decreases mortality rates in acute respiratory distress patients, but to date there has been no investigation of the effect of conservative fluid management on VILI and ventilator associated mortality rates. We hypothesized that age-associated increases in susceptibility and incidence of pulmonary edema strongly promote age-related increases in ventilator associated mortality. Methods 2 month old and 20 month old male C57BL6 mice were mechanically ventilated with either high tidal volume (HVT) or low tidal volume (LVT) for up to 4 hours with either liberal or conservative fluid support. During ventilation, lung compliance, total lung capacity, and hysteresis curves were quantified. Following ventilation, bronchoalveolar lavage fluid was analyzed for total protein content and inflammatory cell infiltration. Wet to dry ratios were used to directly measure edema in excised lungs. Lung histology was performed to quantify alveolar barrier damage/destruction. Age matched non-ventilated mice were used as controls. Results At 4hrs, both advanced age and HVT ventilation significantly increased markers of inflammation and injury, degraded pulmonary mechanics, and decreased survival rates. Conservative fluid support significantly diminished pulmonary edema and improved pulmonary mechanics by 1hr in advanced age HVT subjects. In 4hr ventilations, conservative fluid support significantly diminished pulmonary edema, improved lung mechanics, and resulted in significantly lower mortality rates in older subjects. Conclusion Our study demonstrates that conservative fluid alone can attenuate the age associated increase in ventilator associated mortality. PMID:27188767
Fuller, Brian M; Ferguson, Ian T; Mohr, Nicholas M; Drewry, Anne M; Palmer, Christopher; Wessman, Brian T; Ablordeppey, Enyo; Keeperman, Jacob; Stephens, Robert J; Briscoe, Cristopher C; Kolomiets, Angelina A; Hotchkiss, Richard S; Kollef, Marin H
2017-04-01
To evaluate the impact of an emergency department mechanical ventilation protocol on clinical outcomes and adherence to lung-protective ventilation in patients with acute respiratory distress syndrome. Quasi-experimental, before-after trial. Emergency department and ICUs of an academic center. Mechanically ventilated emergency department patients experiencing acute respiratory distress syndrome while in the emergency department or after admission to the ICU. An emergency department ventilator protocol which targeted variables in need of quality improvement, as identified by prior work: 1) lung-protective tidal volume, 2) appropriate setting of positive end-expiratory pressure, 3) oxygen weaning, and 4) head-of-bed elevation. A total of 229 patients (186 preintervention group, 43 intervention group) were studied. In the emergency department, the intervention was associated with significant changes (p < 0.01 for all) in tidal volume, positive end-expiratory pressure, respiratory rate, oxygen administration, and head-of-bed elevation. There was a reduction in emergency department tidal volume from 8.1 mL/kg predicted body weight (7.0-9.1) to 6.4 mL/kg predicted body weight (6.1-6.7) and an increase in lung-protective ventilation from 11.1% to 61.5%, p value of less than 0.01. The intervention was associated with a reduction in mortality from 54.8% to 39.5% (odds ratio, 0.38; 95% CI, 0.17-0.83; p = 0.02) and a 3.9 day increase in ventilator-free days, p value equals to 0.01. This before-after study of mechanically ventilated patients with acute respiratory distress syndrome demonstrates that implementing a mechanical ventilator protocol in the emergency department is feasible and associated with improved clinical outcomes.
Kallet, Richard H; Campbell, Andre R; Dicker, Rochelle A; Katz, Jeffrey A; Mackersie, Robert C
2006-01-01
To assess the effects of step-changes in tidal volume on work of breathing during lung-protective ventilation in patients with acute lung injury (ALI) or the acute respiratory distress syndrome (ARDS). Prospective, nonconsecutive patients with ALI/ARDS. Adult surgical, trauma, and medical intensive care units at a major inner-city, university-affiliated hospital. Ten patients with ALI/ARDS managed clinically with lung-protective ventilation. Five patients were ventilated at a progressively smaller tidal volume in 1 mL/kg steps between 8 and 5 mL/kg; five other patients were ventilated at a progressively larger tidal volume from 5 to 8 mL/kg. The volume mode was used with a flow rate of 75 L/min. Minute ventilation was maintained constant at each tidal volume setting. Afterward, patients were placed on continuous positive airway pressure for 1-2 mins to measure their spontaneous tidal volume. Work of breathing and other variables were measured with a pulmonary mechanics monitor (Bicore CP-100). Work of breathing progressively increased (0.86 +/- 0.32, 1.05 +/- 0.40, 1.22 +/- 0.36, and 1.57 +/- 0.43 J/L) at a tidal volume of 8, 7, 6, and 5 mL/kg, respectively. In nine of ten patients there was a strong negative correlation between work of breathing and the ventilator-to-patient tidal volume difference (R = -.75 to -.998). : The ventilator-delivered tidal volume exerts an independent influence on work of breathing during lung-protective ventilation in patients with ALI/ARDS. Patient work of breathing is inversely related to the difference between the ventilator-delivered tidal volume and patient-generated tidal volume during a brief trial of unassisted breathing.
Methodological aspects of crossover and maximum fat-oxidation rate point determination.
Michallet, A-S; Tonini, J; Regnier, J; Guinot, M; Favre-Juvin, A; Bricout, V; Halimi, S; Wuyam, B; Flore, P
2008-11-01
Indirect calorimetry during exercise provides two metabolic indices of substrate oxidation balance: the crossover point (COP) and maximum fat oxidation rate (LIPOXmax). We aimed to study the effects of the analytical device, protocol type and ventilatory response on variability of these indices, and the relationship with lactate and ventilation thresholds. After maximum exercise testing, 14 relatively fit subjects (aged 32+/-10 years; nine men, five women) performed three submaximum graded tests: one was based on a theoretical maximum power (tMAP) reference; and two were based on the true maximum aerobic power (MAP). Gas exchange was measured concomitantly using a Douglas bag (D) and an ergospirometer (E). All metabolic indices were interpretable only when obtained by the D reference method and MAP protocol. Bland and Altman analysis showed overestimation of both indices with E versus D. Despite no mean differences between COP and LIPOXmax whether tMAP or MAP was used, the individual data clearly showed disagreement between the two protocols. Ventilation explained 10-16% of the metabolic index variations. COP was correlated with ventilation (r=0.96, P<0.01) and the rate of increase in blood lactate (r=0.79, P<0.01), and LIPOXmax correlated with the ventilation threshold (r=0.95, P<0.01). This study shows that, in fit healthy subjects, the analytical device, reference used to build the protocol and ventilation responses affect metabolic indices. In this population, and particularly to obtain interpretable metabolic indices, we recommend a protocol based on the true MAP or one adapted to include the transition from fat to carbohydrate. The correlation between metabolic indices and lactate/ventilation thresholds suggests that shorter, classical maximum progressive exercise testing may be an alternative means of estimating these indices in relatively fit subjects. However, this needs to be confirmed in patients who have metabolic defects.
Camilo, Luciana M.; Ávila, Mariana B.; Cruz, Luis Felipe S.; Ribeiro, Gabriel C. M.; Spieth, Peter M.; Reske, Andreas A.; Amato, Marcelo; Giannella-Neto, Antonio; Zin, Walter A.; Carvalho, Alysson R.
2014-01-01
Objectives Variable ventilation (VV) seems to improve respiratory function in acute lung injury and may be combined with positive end-expiratory pressure (PEEP) in order to protect the lungs even in healthy subjects. We hypothesized that VV in combination with moderate levels of PEEP reduce the deterioration of pulmonary function related to general anesthesia. Hence, we aimed at evaluating the alveolar stability and lung protection of the combination of VV at different PEEP levels. Design Randomized experimental study. Setting Animal research facility. Subjects Forty-nine male Wistar rats (200–270 g). Interventions Animals were ventilated during 2 hours with protective low tidal volume (VT) in volume control ventilation (VCV) or VV and PEEP adjusted at the level of minimum respiratory system elastance (Ers), obtained during a decremental PEEP trial subsequent to a recruitment maneuver, and 2 cmH2O above or below of this level. Measurements and Main Results Ers, gas exchange and hemodynamic variables were measured. Cytokines were determined in lung homogenate and plasma samples and left lung was used for histologic analysis and diffuse alveolar damage scoring. A progressive time-dependent increase in Ers was observed independent on ventilatory mode or PEEP level. Despite of that, the rate of increase of Ers and lung tissue IL-1 beta concentration were significantly lower in VV than in VCV at the level of the PEEP of minimum Ers. A significant increase in lung tissue cytokines (IL-6, IL-1 beta, CINC-1 and TNF-alpha) as well as a ventral to dorsal and cranial to caudal reduction in aeration was observed in all ventilated rats with no significant differences among groups. Conclusions VV combined with PEEP adjusted at the level of the PEEP of minimal Ers seemed to better prevent anesthesia-induced atelectasis and might improve lung protection throughout general anesthesia. PMID:25383882
Kim, Ji Hoon; Beom, Jin Ho; You, Je Sung; Cho, Junho; Min, In Kyung; Chung, Hyun Soo
2018-01-01
Several auditory-based feedback devices have been developed to improve the quality of ventilation performance during cardiopulmonary resuscitation (CPR), but their effectiveness has not been proven in actual CPR situations. In the present study, we investigated the effectiveness of visual flashlight guidance in maintaining high-quality ventilation performance. We conducted a simulation-based, randomized, parallel trial including 121 senior medical students. All participants were randomized to perform ventilation during 2 minutes of CPR with or without flashlight guidance. For each participant, we measured mean ventilation rate as a primary outcome and ventilation volume, inspiration velocity, and ventilation interval as secondary outcomes using a computerized device system. Mean ventilation rate did not significantly differ between flashlight guidance and control groups (P = 0.159), but participants in the flashlight guidance group exhibited significantly less variation in ventilation rate than participants in the control group (P<0.001). Ventilation interval was also more regular among participants in the flashlight guidance group. Our results demonstrate that flashlight guidance is effective in maintaining a constant ventilation rate and interval. If confirmed by further studies in clinical practice, flashlight guidance could be expected to improve the quality of ventilation performed during CPR.
Harmon, Matthew B A; van Meenen, David M P; van der Veen, Annelou L I P; Binnekade, Jan M; Dankiewicz, Josef; Ebner, Florian; Nielsen, Niklas; Pelosi, Paolo; Schultz, Marcus J; Horn, Janneke; Friberg, Hans; Juffermans, Nicole P
2018-05-12
Mechanical ventilation practices in patients with cardiac arrest are not well described. Also, the effect of temperature on mechanical ventilation settings is not known. The aims of this study were 1) to describe practice of mechanical ventilation and its relation with outcome 2) to determine effects of different target temperatures strategies (33 °C versus 36 °C) on mechanical ventilation settings. This is a substudy of the TTM-trial in which unconscious survivors of a cardiac arrest due to a cardiac cause were randomized to two TTM strategies, 33 °C (TTM33) and 36 °C (TTM36). Mechanical ventilation data were obtained at three time points: 1) before TTM; 2) at the end of TTM (before rewarming) and 3) after rewarming. Logistic regression was used to determine an association between mechanical ventilation variables and outcome. Repeated-measures mixed modelling was performed to determine the effect of TTM on ventilation settings. Mechanical ventilation data was available for 567 of the 950 TTM patients. Of these, 81% was male with a mean (SD) age of 64 (12) years. At the end of TTM median tidal volume was 7.7 ml/kg predicted body weight (PBW)(6.4-8.7) and 60% of patients were ventilated with a tidal volume ≤ 8 ml/kg PBW. Median PEEP was 7.7cmH 2 O (6.4-8.7) and mean driving pressure was 14.6 cmH 2 O (±4.3). The median FiO 2 fraction was 0.35 (0.30-0.45). Multivariate analysis showed an independent relationship between increased respiratory rate and 28-day mortality. TTM33 resulted in lower end-tidal CO 2 (Pgroup = 0.0003) and higher alveolar dead space fraction (Pgroup = 0.003) compared to TTM36, while PCO 2 levels and respiratory minute volume were similar between groups. In the majority of the cardiac arrest patients, protective ventilation settings are applied, including low tidal volumes and driving pressures. High respiratory rate was associated with mortality. TTM33 results in lower end-tidal CO 2 levels and a higher alveolar dead space fraction compared to TTTM36. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Interactive simulation system for artificial ventilation on the internet: virtual ventilator.
Takeuchi, Akihiro; Abe, Tadashi; Hirose, Minoru; Kamioka, Koichi; Hamada, Atsushi; Ikeda, Noriaki
2004-12-01
To develop an interactive simulation system "virtual ventilator" that demonstrates the dynamics of pressure and flow in the respiratory system under the combination of spontaneous breathing, ventilation modes, and ventilator options. The simulation system was designed to be used by unexperienced health care professionals as a self-training tool. The system consists of a simulation controller and three modules: respiratory, spontaneous breath, and ventilator. The respiratory module models the respiratory system by three resistances representing the main airway, the right and left lungs, and two compliances also representing the right and left lungs. The spontaneous breath module generates inspiratory negative pressure produced by a patient. The ventilator module generates driving force of pressure or flow according to the combination of the ventilation mode and options. These forces are given to the respiratory module through the simulation controller. The simulation system was developed using HTML, VBScript (3000 lines, 100 kB) and ActiveX control (120 kB), and runs on Internet Explorer (5.5 or higher). The spontaneous breath is defined by a frequency, amplitude and inspiratory patterns in the spontaneous breath module. The user can construct a ventilation mode by setting a control variable, phase variables (trigger, limit, and cycle), and options. Available ventilation modes are: controlled mechanical ventilation (CMV), continuous positive airway pressure, synchronized intermittent mandatory ventilation (SIMV), pressure support ventilation (PSV), SIMV + PSV, pressure-controlled ventilation (PCV), pressure-regulated volume control (PRVC), proportional assisted ventilation, mandatory minute ventilation (MMV), bilevel positive airway pressure (BiPAP). The simulation system demonstrates in a graph and animation the airway pressure, flow, and volume of the respiratory system during mechanical ventilation both with and without spontaneous breathing. We developed a web application that demonstrated the respiratory mechanics and the basic theory of ventilation mode.
Sundar, Krishna M; Nielsen, David; Sperry, Paul
2012-02-01
Ventilator-associated pneumonia (VAP) is associated with significant morbidity and mortality. Measures to reduce the incidence of VAP have resulted in institutions reporting a zero or near-zero VAP rates. The implications of zero VAP rates are unclear. This study was done to compare outcomes between two intensive care units (ICU) with one of them reporting a zero VAP rate. This study retrospectively compared VAP rates between two ICUs: Utah Valley Regional Medical Center (UVRMC) with 25 ICU beds and American Fork Hospital (AFH) with 9 ICU beds. Both facilities are under the same management and attended by a single group of intensivists. Both ICUs have similar nursing and respiratory staffing patterns. Both ICUs use the same intensive care program for reduction of VAP rates. ICU outcomes between AFH (reporting zero VAP rate) and UVRMC (VAP rate of 2.41/1000 ventilator days) were compared for the years 2007-2008. UVRMC VAP rates during 2007 and 2008 were 2.31/1000 ventilator days and 2.5/1000 ventilator days respectively compared to a zero VAP rate at AFH. The total days of ventilation, mean days of ventilation per patient and mean duration of ICU stay per patient was higher in the UVRMC group as compared to AFH ICU group. There was no significant difference in mean age and APACHE II score between ICU patients at UVRMC and AFH. There was no statistical difference in rates of VAP and mortality between UVRMC and AFH. During comparisons of VAP rate between institutions, a zero VAP rate needs to be considered in the context of overall ventilator days, mean durations of ventilator stay and ICU mortality. Copyright © 2012 Elsevier Inc. All rights reserved.
Association between substandard classroom ventilation rates and students' academic achievement.
Haverinen-Shaughnessy, U; Moschandreas, D J; Shaughnessy, R J
2011-04-01
This study focuses on the relationship between classroom ventilation rates and academic achievement. One hundred elementary schools of two school districts in the southwest United States were included in the study. Ventilation rates were estimated from fifth-grade classrooms (one per school) using CO(2) concentrations measured during occupied school days. In addition, standardized test scores and background data related to students in the classrooms studied were obtained from the districts. Of 100 classrooms, 87 had ventilation rates below recommended guidelines based on ASHRAE Standard 62 as of 2004. There is a linear association between classroom ventilation rates and students' academic achievement within the range of 0.9-7.1 l/s per person. For every unit (1 l/s per person) increase in the ventilation rate within that range, the proportion of students passing standardized test (i.e., scoring satisfactory or above) is expected to increase by 2.9% (95%CI 0.9-4.8%) for math and 2.7% (0.5-4.9%) for reading. The linear relationship observed may level off or change direction with higher ventilation rates, but given the limited number of observations, we were unable to test this hypothesis. A larger sample size is needed for estimating the effect of classroom ventilation rates higher than 7.1 l/s per person on academic achievement. The results of this study suggest that increasing the ventilation rates toward recommended guideline ventilation rates in classrooms should translate into improved academic achievement of students. More studies are needed to fully understand the relationships between ventilation rate, other indoor environmental quality parameters, and their effects on students' health and achievement. Achieving the recommended guidelines and pursuing better understanding of the underlying relationships would ultimately support both sustainable and productive school environments for students and personnel. © 2010 John Wiley & Sons A/S.
Feasibility of the capnogram to monitor ventilation rate during cardiopulmonary resuscitation.
Aramendi, Elisabete; Elola, Andoni; Alonso, Erik; Irusta, Unai; Daya, Mohamud; Russell, James K; Hubner, Pia; Sterz, Fritz
2017-01-01
The rates of chest compressions (CCs) and ventilations are both important metrics to monitor the quality of cardiopulmonary resuscitation (CPR). Capnography permits monitoring ventilation, but the CCs provided during CPR corrupt the capnogram and compromise the accuracy of automatic ventilation detectors. The aim of this study was to evaluate the feasibility of an automatic algorithm based on the capnogram to detect ventilations and provide feedback on ventilation rate during CPR, specifically addressing intervals where CCs are delivered. The dataset used to develop and test the algorithm contained in-hospital and out-of-hospital cardiac arrest episodes. The method relies on adaptive thresholding to detect ventilations in the first derivative of the capnogram. The performance of the detector was reported in terms of sensitivity (SE) and Positive Predictive Value (PPV). The overall performance was reported in terms of the rate error and errors in the hyperventilation alarms. Results were given separately for the intervals with CCs. A total of 83 episodes were considered, resulting in 4880min and 46,740 ventilations (8741 during CCs). The method showed an overall SE/PPV above 99% and 97% respectively, even in intervals with CCs. The error for the ventilation rate was below 1.8min -1 in any group, and >99% of the ventilation alarms were correctly detected. A method to provide accurate feedback on ventilation rate using only the capnogram is proposed. Its accuracy was proven even in intervals where canpography signal was severely corrupted by CCs. This algorithm could be integrated into monitor/defibrillators to provide reliable feedback on ventilation rate during CPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Newth, Christopher J L; Sward, Katherine A; Khemani, Robinder G; Page, Kent; Meert, Kathleen L; Carcillo, Joseph A; Shanley, Thomas P; Moler, Frank W; Pollack, Murray M; Dalton, Heidi J; Wessel, David L; Berger, John T; Berg, Robert A; Harrison, Rick E; Holubkov, Richard; Doctor, Allan; Dean, J Michael; Jenkins, Tammara L; Nicholson, Carol E
2017-11-01
Although pediatric intensivists philosophically embrace lung protective ventilation for acute lung injury and acute respiratory distress syndrome, we hypothesized that ventilator management varies. We assessed ventilator management by evaluating changes to ventilator settings in response to blood gases, pulse oximetry, or end-tidal CO2. We also assessed the potential impact that a pediatric mechanical ventilation protocol adapted from National Heart Lung and Blood Institute acute respiratory distress syndrome network protocols could have on reducing variability by comparing actual changes in ventilator settings to those recommended by the protocol. Prospective observational study. Eight tertiary care U.S. PICUs, October 2011 to April 2012. One hundred twenty patients (age range 17 d to 18 yr) with acute lung injury/acute respiratory distress syndrome. Two thousand hundred arterial and capillary blood gases, 3,964 oxygen saturation by pulse oximetry, and 2,757 end-tidal CO2 values were associated with 3,983 ventilator settings. Ventilation mode at study onset was pressure control 60%, volume control 19%, pressure-regulated volume control 18%, and high-frequency oscillatory ventilation 3%. Clinicians changed FIO2 by ±5 or ±10% increments every 8 hours. Positive end-expiratory pressure was limited at ~10 cm H2O as oxygenation worsened, lower than would have been recommended by the protocol. In the first 72 hours of mechanical ventilation, maximum tidal volume/kg using predicted versus actual body weight was 10.3 (8.5-12.9) (median [interquartile range]) versus 9.2 mL/kg (7.6-12.0) (p < 0.001). Intensivists made changes similar to protocol recommendations 29% of the time, opposite to the protocol's recommendation 12% of the time and no changes 56% of the time. Ventilator management varies substantially in children with acute respiratory distress syndrome. Opportunities exist to minimize variability and potentially injurious ventilator settings by using a pediatric mechanical ventilation protocol offering adequately explicit instructions for given clinical situations. An accepted protocol could also reduce confounding by mechanical ventilation management in a clinical trial.
The ventilation problem in schools: literature review
Fisk, W. J.
2017-07-06
Based on a review of literature published in refereed archival journals, ventilation rates in classrooms often fall far short of the minimum ventilation rates specified in standards. We report that there is compelling evidence, from both cross-sectional and intervention studies, of an association of increased student performance with increased ventilation rates. There is evidence that reduced respiratory health effects and reduced student absence are associated with increased ventilation rates. Increasing ventilation rates in schools imposes energy costs and can increase heating, ventilating, and air-conditioning system capital costs. The net annual costs, ranging from a few dollars to about 10 dollarsmore » per person, are less than 0.1% of typical public spending on elementary and secondary education in the United States. Finally, such expenditures seem like a small price to pay given the evidence of health and performance benefits.« less
The ventilation problem in schools: literature review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisk, W. J.
Based on a review of literature published in refereed archival journals, ventilation rates in classrooms often fall far short of the minimum ventilation rates specified in standards. We report that there is compelling evidence, from both cross-sectional and intervention studies, of an association of increased student performance with increased ventilation rates. There is evidence that reduced respiratory health effects and reduced student absence are associated with increased ventilation rates. Increasing ventilation rates in schools imposes energy costs and can increase heating, ventilating, and air-conditioning system capital costs. The net annual costs, ranging from a few dollars to about 10 dollarsmore » per person, are less than 0.1% of typical public spending on elementary and secondary education in the United States. Finally, such expenditures seem like a small price to pay given the evidence of health and performance benefits.« less
Effect of ventilation rate on air cleanliness and energy consumption in operation rooms at rest.
Lee, Shih-Tseng; Liang, Ching-Chieh; Chien, Tsung-Yi; Wu, Feng-Jen; Fan, Kuang-Chung; Wan, Gwo-Hwa
2018-02-27
The interrelationships between ventilation rate, indoor air quality, and energy consumption in operation rooms at rest are yet to be understood. We investigate the effect of ventilation rate on indoor air quality indices and energy consumption in ORs at rest. The study investigates the air temperature, relative humidity, concentrations of carbon dioxide, particulate matter (PM), and airborne bacteria at different ventilation rates in operation rooms at rest of a medical center. The energy consumption and cost analysis of the heating, ventilating, and air conditioning (HVAC) system in the operation rooms at rest were also evaluated for all ventilation rates. No air-conditioned operation rooms had very highest PM and airborne bacterial concentrations in the operation areas. The bacterial concentration in the operation areas with 6-30 air changes per hour (ACH) was below the suggested level set by the United Kingdom (UK) for an empty operation room. A 70% of reduction in annual energy cost by reducing the ventilation rate from 30 to 6 ACH was found in the operation rooms at rest. Maintenance of operation rooms at ventilation rate of 6 ACH could save considerable amounts of energy and achieve the goal of air cleanliness.
Imamura, Teruhiko; Nitta, Daisuke; Kinugawa, Koichiro
2017-01-05
Adaptive servo-ventilation (ASV) therapy is a recent non-invasive positive pressure ventilation therapy that was developed for patients with heart failure (HF) refractory to optimal medical therapy. However, it is likely that ASV therapy at relatively higher pressure setting worsens some of the patients' prognosis compared with optimal medical therapy. Therefore, identification of optimal pressure settings of ASV therapy is warranted. We present the case of a 42-year-old male with HF, which was caused by dilated cardiomyopathy, who was admitted to our institution for evaluating his eligibility for heart transplantation. To identify the optimal pressure setting [peak end-expiratory pressure (PEEP) ramp test], we performed an ASV support test, during which the PEEP settings were set at levels ranging from 4 to 8 mmHg, and a heart rate variability (HRV) analysis using the MemCalc power spectral density method. Clinical parameters varied dramatically during the PEEP ramp test. Over incremental PEEP levels, pulmonary capillary wedge pressure, cardiac index and high-frequency level (reflecting parasympathetic activity) decreased; however, the low-frequency level increased along with increase in plasma noradrenaline concentrations. An inappropriately high PEEP setting may stimulate sympathetic nerve activity accompanied by decreased cardiac output. This was the first report on the PEEP ramp test during ASV therapy. Further research is warranted to determine whether use of optimal pressure settings using HRV analyses may improve the long-term prognosis of such patients.
Beda, Alessandro; Güldner, Andreas; Simpson, David M; Carvalho, Nadja C; Franke, Susanne; Uhlig, Christopher; Koch, Thea; Pelosi, Paolo; de Abreu, Marcelo Gama
2012-03-01
The physiological importance of respiratory sinus arrhythmia (RSA) and cardioventilatory coupling (CVC) has not yet been fully elucidated, but these phenomena might contribute to improve ventilation/perfusion matching, with beneficial effects on gas exchange. Furthermore, decreased RSA amplitude has been suggested as an indicator of impaired autonomic control and poor clinical outcome, also during positive-pressure mechanical ventilation (MV). However, it is currently unknown how different modes of MV, including variable tidal volumes (V(T)), affect RSA and CVC during anesthesia. We compared the effects of pressure controlled (PCV) versus pressure assisted (PSV) ventilation, and of random variable versus constant V(T), on RSA and CVC in eight anesthetized pigs. At comparable depth of anesthesia, global hemodynamics, and ventilation, RSA amplitude increased from 20 ms in PCV to 50 ms in PSV (p < 0.05). CVC was detected (using proportional Shannon entropy of the interval between each inspiration onset and the previous R-peak in ECG) in two animals in PCV and seven animals in PSV. Variable V(T) did not significantly influence these phenomena. Furthermore, heart period and systolic arterial pressure oscillations were in phase during PCV but in counter-phase during PSV. At the same depth of anesthesia in pigs, PSV increases RSA amplitude and CVC compared to PCV. Our data suggest that the central respiratory drive, but not the baroreflex or the mechano-electric feedback in the heart, is the main mechanism behind the RSA increase. Hence, differences in RSA and CVC between mechanically ventilated patients might reflect the difference in ventilation mode rather than autonomic impairment. Also, since gas exchange did not increase from PCV to PSV, it is questionable whether RSA has any significance in improving ventilation/perfusion matching during MV.
Rackes, A; Ben-David, T; Waring, M S
2018-07-01
This article presents an outcome-based ventilation (OBV) framework, which combines competing ventilation impacts into a monetized loss function ($/occ/h) used to inform ventilation rate decisions. The OBV framework, developed for U.S. offices, considers six outcomes of increasing ventilation: profitable outcomes realized from improvements in occupant work performance and sick leave absenteeism; health outcomes from occupant exposure to outdoor fine particles and ozone; and energy outcomes from electricity and natural gas usage. We used the literature to set low, medium, and high reference values for OBV loss function parameters, and evaluated the framework and outcome-based ventilation rates using a simulated U.S. office stock dataset and a case study in New York City. With parameters for all outcomes set at medium values derived from literature-based central estimates, higher ventilation rates' profitable benefits dominated negative health and energy impacts, and the OBV framework suggested ventilation should be ≥45 L/s/occ, much higher than the baseline ~8.5 L/s/occ rate prescribed by ASHRAE 62.1. Only when combining very low parameter estimates for profitable impacts with very high ones for health and energy impacts were all outcomes on the same order. Even then, however, outcome-based ventilation rates were often twice the baseline rate or more. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
EPA announced the availability of the final report, Metabolically Derived Human Ventilation Rates: A Revised Approach Based Upon Oxygen Consumption Rates. This report provides a revised approach for calculating an individual's ventilation rate directly from their oxygen c...
Linking In-Vehicle Ultrafine Particle Exposures to On-Road Concentrations
Hudda, Neelakshi; Eckel, Sandrah P.; Knibbs, Luke D.; Sioutas, Constantinos; Delfino, Ralph J.; Fruin, Scott A.
2013-01-01
For traffic-related pollutants like ultrafine particles (UFP, Dp < 100 nm), a significant fraction of overall exposure occurs within or close to the transit microenvironment. Therefore, understanding exposure to these pollutants in such microenvironments is crucial to accurately assessing overall UFP exposure. The aim of this study was to develop models for predicting in-cabin UFP concentrations if roadway concentrations are known, taking into account vehicle characteristics, ventilation settings, driving conditions and air exchange rates (AER). Particle concentrations and AER were measured in 43 and 73 vehicles, respectively, under various ventilation settings and driving speeds. Multiple linear regression (MLR) and generalized estimating equation (GEE) regression models were used to identify and quantify the factors that determine inside-to-outside (I/O) UFP ratios and AERs across a full range of vehicle types and ages. AER was the most significant determinant of UFP I/O ratios, and was strongly influenced by ventilation setting (recirculation or outside air intake). Inclusion of ventilation fan speed, vehicle age or mileage, and driving speed explained greater than 79% of the variability in measured UFP I/O ratios. PMID:23888122
Zaydfudim, Victor; Dossett, Lesly A; Starmer, John M; Arbogast, Patrick G; Feurer, Irene D; Ray, Wayne A; May, Addison K; Pinson, C Wright
2009-07-01
Ventilator-associated pneumonia (VAP) causes significant morbidity and mortality in critically ill surgical patients. Recent studies suggest that the success of preventive measures is dependent on compliance with ventilator bundle parameters. Implementation of an electronic dashboard will improve compliance with the bundle parameters and reduce rates of VAP in our surgical intensive care unit (SICU). Time series analysis of VAP rates between January 2005 and July 2008, with dashboard implementation in July 2007. Multidisciplinary SICU at a tertiary-care referral center with a stable case mix during the study period. Patients admitted to the SICU between January 2005 and July 2008. Infection control data were used to establish rates of VAP and total ventilator days. For the time series analysis, VAP rates were calculated as quarterly VAP events per 1000 ventilator days. Ventilator bundle compliance was analyzed after dashboard implementation. Differences between expected and observed VAP rates based on time series analysis were used to estimate the effect of intervention. Average compliance with the ventilator bundle improved from 39% in August 2007 to 89% in July 2008 (P < .001). Rates of VAP decreased from a mean (SD) of 15.2 (7.0) to 9.3 (4.9) events per 1000 ventilator days after introduction of the dashboard (P = .01). Quarterly VAP rates were significantly reduced in the November 2007 through January 2008 and February through April 2008 periods (P < .05). For the August through October 2007 and May through July 2008 quarters, the observed rate reduction was not statistically significant. Implementation of an electronic dashboard improved compliance with ventilator bundle measures and is associated with reduced rates of VAP in our SICU.
Tabernero Huguet, Eva; Gil Alaña, Pilar; Arana-Arri, Eunate; Citores Martín, Leyre; Alkiza Basañez, Ramon; Hernandez Gil, Anibal; Gil Molet, Alejandra
2016-01-01
Elderly patients with multiple morbidity and do not intubate (DNI) orders frequently present with acute respiratory failure. There are data supporting the effectiveness of non-invasive ventilation (NIV) in this context. Our chronic disease hospital developed an integrated care clinical pathway for the use of NIV in acute respiratory failure in the emergency room and wards in 2010. The aim of this study was to assess the outcome of NIV in patients with acute respiratory failure who had a DNI order in a sub-acute care hospital. Observational, one year-follow up study. The main variables were in-hospital mortality and one year mortality. Other variables recorded were: demographics, clinical data, functional data, performance of daily life activities, dementia, arterial blood gases and re-admissions. The study included a total of 102 patients, of which 22% were in institutions. The mean age 81±7.47% males, with a Charlson index 3.7±1, and Barthel index 54±31. The overall mortality during the admission was 33% (34 patients). Among those patients ventilated outside the protocol indication, the mortality was significantly greater, at 71% (P>.05). Overall one-year survival rate was 46%. This survival rate was statistically higher in patients with obesity hypoventilation syndrome and a Barthel >50. NIV is a useful technique in a hospital for chronic patients in an elderly population with a therapeutic ceiling. Despite their disease severity and comorbidity, acceptable survival rates are achieved. A correct case selection is needed. Obesity hypoventilation syndrome and those with Barthel index >50 have a better prognosis. Copyright © 2015 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.
A new global and comprehensive model for ICU ventilator performances evaluation.
Marjanovic, Nicolas S; De Simone, Agathe; Jegou, Guillaume; L'Her, Erwan
2017-12-01
This study aimed to provide a new global and comprehensive evaluation of recent ICU ventilators taking into account both technical performances and ergonomics. Six recent ICU ventilators were evaluated. Technical performances were assessed under two FIO 2 levels (100%, 50%), three respiratory mechanics combinations (Normal: compliance [C] = 70 mL cmH 2 O -1 /resistance [R] = 5 cmH 2 O L -1 s -1 ; Restrictive: C = 30/R = 10; Obstructive: C = 120/R = 20), four exponential levels of leaks (from 0 to 12.5 L min -1 ) and three levels of inspiratory effort (P0.1 = 2, 4 and 8 cmH 2 O), using an automated test lung. Ergonomics were evaluated by 20 ICU physicians using a global and comprehensive model involving physiological response to stress measurements (heart rate, respiratory rate, tidal volume variability and eye tracking), psycho-cognitive scales (SUS and NASA-TLX) and objective tasks completion. Few differences in terms of technical performance were observed between devices. Non-invasive ventilation modes had a huge influence on asynchrony occurrence. Using our global model, either objective tasks completion, psycho-cognitive scales and/or physiological measurements were able to depict significant differences in terms of devices' usability. The level of failure that was observed with some devices depicted the lack of adaptation of device's development to end users' requests. Despite similar technical performance, some ICU ventilators exhibit low ergonomics performance and a high risk of misusage.
Li, Ya-Chi; Lin, Hui-Ling; Liao, Fang-Chun; Wang, Sing-Siang; Chang, Hsiu-Chu; Hsu, Hung-Fu; Chen, Sue-Hsien; Wan, Gwo-Hwa
2018-01-01
Few studies have investigated the difference in bacterial contamination between conventional reused ventilator systems and disposable closed ventilator-suction systems. The aim of this study was to investigate the bacterial contamination rates of the reused and disposable ventilator systems, and the association between system disconnection and bacterial contamination of ventilator systems. The enrolled intubated and mechanically ventilated patients used a conventional reused ventilator system and a disposable closed ventilator-suction system, respectively, for a week; specimens were then collected from the ventilator circuit systems to evaluate human and environmental bacterial contamination. The sputum specimens from patients were also analyzed in this study. The detection rate of bacteria in the conventional reused ventilator system was substantially higher than that in the disposable ventilator system. The inspiratory and expiratory limbs of the disposable closed ventilator-suction system had higher bacterial concentrations than the conventional reused ventilator system. The bacterial concentration in the heated humidifier of the reused ventilator system was significantly higher than that in the disposable ventilator system. Positive associations existed among the bacterial concentrations at different locations in the reused and disposable ventilator systems, respectively. The predominant bacteria identified in the reused and disposable ventilator systems included Acinetobacter spp., Bacillus cereus, Elizabethkingia spp., Pseudomonas spp., and Stenotrophomonas (Xan) maltophilia. Both the reused and disposable ventilator systems had high bacterial contamination rates after one week of use. Disconnection of the ventilator systems should be avoided during system operation to decrease the risks of environmental pollution and human exposure, especially for the disposable ventilator system. ClinicalTrials.gov PRS / NCT03359148.
Contaminant levels, source strengths, and ventilation rates in California retail stores.
Chan, W R; Cohn, S; Sidheswaran, M; Sullivan, D P; Fisk, W J
2015-08-01
This field study measured ventilation rates and indoor air quality in 21 visits to retail stores in California. Three types of stores, such as grocery, furniture/hardware stores, and apparel, were sampled. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California's Title 24 Standard in all but one store. Concentrations of volatile organic compounds (VOCs), ozone, and carbon dioxide measured indoors and outdoors were analyzed. Even though there was adequate ventilation according to standard, concentrations of formaldehyde and acetaldehyde exceeded the most stringent chronic health guidelines in many of the sampled stores. The whole-building emission rates of VOCs were estimated from the measured ventilation rates and the concentrations measured indoor and outdoor. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California's stringent formaldehyde reference level. Given the high costs of providing ventilation, effective source control is an attractive alternative. Field measurements suggest that California retail stores were well ventilated relative to the minimum ventilation rate requirement specified in the Building Energy Efficiency Standards Title 24. Concentrations of formaldehyde found in retail stores were low relative to levels found in homes but exceeded the most stringent chronic health guideline. Looking ahead, California is mandating zero energy commercial buildings by 2030. To reduce the energy use from building ventilation while maintaining or even lowering formaldehyde in retail stores, effective formaldehyde source control measures are vitally important. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
Dongelmans, Dave A; Paulus, Frederique; Veelo, Denise P; Binnekade, Jan M; Vroom, Margreeth B; Schultz, Marcus J
2011-05-01
With adaptive support ventilation, respiratory rate and tidal volume (V(T)) are a function of the Otis least work of breathing formula. We hypothesized that adaptive support ventilation in an open lung ventilator strategy would deliver higher V(T)s to patients with acute lung injury. Patients with acute lung injury were ventilated according to a local guideline advising the use of lower V(T) (6-8 ml/kg predicted body weight), high concentrations of positive end-expiratory pressure, and recruitment maneuvers. Ventilation parameters were recorded when the ventilator was switched to adaptive support ventilation, and after recruitment maneuvers. If V(T) increased more than 8 ml/kg predicted body weight, airway pressure was limited to correct for the rise of V(T). Ten patients with a mean (±SD) Pao(2)/Fio(2) of 171 ± 86 mmHg were included. After a switch from pressure-controlled ventilation to adaptive support ventilation, respiratory rate declined (from 31 ± 5 to 21 ± 6 breaths/min; difference = 10 breaths/min, 95% CI 3-17 breaths/min, P = 0.008) and V(T) increased (from 6.5 ± 0.8 to 9.0 ± 1.6 ml/kg predicted body weight; difference = 2.5 ml, 95% CI 0.4-4.6 ml/kg predicted body weight, P = 0.02). Pressure limitation corrected for the rise of V(T), but minute ventilation declined, forcing the user to switch back to pressure-controlled ventilation. Adaptive support ventilation, compared with pressure-controlled ventilation in an open lung strategy setting, delivers a lower respiratory rate-higher V(T) combination. Pressure limitation does correct for the rise of V(T), but leads to a decline in minute ventilation.
Biermann, A; Geissler, A
2016-09-01
Diagnosis-related groups (DRGs) have been used to reimburse hospitals services in Germany since 2003/04. Like any other reimbursement system, DRGs offer specific incentives for hospitals that may lead to unintended consequences for patients. In the German context, specific procedures and their documentation are suspected to be primarily performed to increase hospital revenues. Mechanical ventilation of patients and particularly the duration of ventilation, which is an important variable for the DRG-classification, are often discussed to be among these procedures. The aim of this study was to examine incentives created by the German DRG-based payment system with regard to mechanical ventilation and to identify factors that explain the considerable increase of mechanically ventilated patients in recent years. Moreover, the assumption that hospitals perform mechanical ventilation in order to gain economic benefits was examined. In order to gain insights on the development of the number of mechanically ventilated patients, patient-level data provided by the German Federal Statistical Office and the German Institute for the Hospital Remuneration System were analyzed. The type of performed ventilation, the total number of ventilation hours, the age distribution, mortality and the DRG distribution for mechanical ventilation were calculated, using methods of descriptive and inferential statistics. Furthermore, changes in DRG-definitions and changes in respiratory medicine were compared for the years 2005-2012. Since the introduction of the DRG-based payment system in Germany, the hours of ventilation and the number of mechanically ventilated patients have substantially increased, while mortality has decreased. During the same period there has been a switch to less invasive ventilation methods. The age distribution has shifted to higher age-groups. A ventilation duration determined by DRG definitions could not be found. Due to advances in respiratory medicine, new ventilation methods have been introduced that are less prone to complications. This development has simultaneously improved survival rates. There was no evidence supporting the assumption that the duration of mechanical ventilation is influenced by the time intervals relevant for DRG grouping. However, presumably operational routines such as staff availability within early and late shifts of the hospital have a significant impact on the termination of mechanical ventilation.
Effects of types of ventilation system on indoor particle concentrations in residential buildings.
Park, J S; Jee, N-Y; Jeong, J-W
2014-12-01
The objective of this study was to quantify the influence of ventilation systems on indoor particle concentrations in residential buildings. Fifteen occupied, single-family apartments were selected from three sites. The three sites have three different ventilation systems: unbalanced mechanical ventilation, balanced mechanical ventilation, and natural ventilation. Field measurements were conducted between April and June 2012, when outdoor air temperatures were comfortable. Number concentrations of particles, PM2.5 and CO2 , were continuously measured both outdoors and indoors. In the apartments with natural ventilation, I/O ratios of particle number concentrations ranged from 0.56 to 0.72 for submicron particles, and from 0.25 to 0.60 for particles larger than 1.0 μm. The daily average indoor particle concentration decreased to 50% below the outdoor level for submicron particles and 25% below the outdoor level for fine particles, when the apartments were mechanically ventilated. The two mechanical ventilation systems reduced the I/O ratios by 26% for submicron particles and 65% for fine particles compared with the natural ventilation. These results showed that mechanical ventilation can reduce exposure to outdoor particles in residential buildings. Results of this study confirm that mechanical ventilation with filtration can significantly reduce indoor particle levels compared with natural ventilation. The I/O ratios of particles substantially varied at the naturally ventilated apartments because of the influence of variable window opening conditions and unsteadiness of wind flow on the penetration of outdoor air particles. For better prediction of the exposure to outdoor particles in naturally ventilated residential buildings, it is important to understand the penetration of outdoor particles with variable window opening conditions. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Variability in the Use of Protective Mechanical Ventilation During General Anesthesia.
Ladha, Karim S; Bateman, Brian T; Houle, Timothy T; De Jong, Myrthe A C; Vidal Melo, Marcos F; Huybrechts, Krista F; Kurth, Tobias; Eikermann, Matthias
2018-02-01
The purpose of this study was to determine whether significant variation exists in the use of protective ventilation across individual anesthesia providers and whether this difference can be explained by patient, procedure, and provider-related characteristics. The cohort consisted of 262 anesthesia providers treating 57,372 patients at a tertiary care hospital between 2007 and 2014. Protective ventilation was defined as a median positive end-expiratory pressure of 5 cm H2O or more, tidal volume of <10 mL/kg of predicted body weight and plateau pressure of <30 cm H2O. Analysis was performed using mixed-effects logistic regression models with propensity scores to adjust for covariates. The definition of protective ventilation was modified in sensitivity analyses. In unadjusted analysis, the mean probability of administering protective ventilation was 53.8% (2.5th percentile of provider 19.9%, 97.5th percentile 80.8%). After adjustment for a large number of covariates, there was little change in the results with a mean probability of 51.1% (2.5th percentile 24.7%, 97.5th percentile 77.2%). The variations persisted when the thresholds for protective ventilation were changed. There was significant variability across individual anesthesia providers in the use of intraoperative protective mechanical ventilation. Our data suggest that this variability is highly driven by individual preference, rather than patient, procedure, or provider-related characteristics.
Functional differences in bi-level pressure preset ventilators.
Highcock, M P; Shneerson, J M; Smith, I E
2001-02-01
The performance of four bilevel positive pressure preset ventilators was compared. The ventilators tested were; BiPAP ST30 (Respironics); Nippy2 (B + D Electrical); Quantum PSV (Healthdyne); and Sullivan VPAP H ST (Resmed). A patient simulator was used to determine the sensitivity of the triggering mechanisms and the responses to a leak within the patient circuit, and to changes in patient effort. Significant differences (p <0.05) between the devices were seen in the trigger delay time and inspiratory trigger pressure. When a leak was introduced into the patient circuit, the fall in tidal volume (VT) was less than ten per cent for each ventilator. The addition of patient effort produced a number of changes in the ventilation delivered. Patient efforts of 0.25 s induced a variable fall in VT. An increase in VT was seen with some ventilators with patient efforts of 1 s but the effect was variable. Trigger failures and subsequent falls in minute volume were seen with the BiPAP and the Nippy2 at the highest respiratory frequency. Differences in the responses of the ventilators are demonstrated that may influence the selection of a ventilator, particularly in the treatment of breathless patients with ventilatory failure.
Li, Ya-Chi; Lin, Hui-Ling; Liao, Fang-Chun; Wang, Sing-Siang; Chang, Hsiu-Chu; Hsu, Hung-Fu; Chen, Sue-Hsien
2018-01-01
Background Few studies have investigated the difference in bacterial contamination between conventional reused ventilator systems and disposable closed ventilator-suction systems. The aim of this study was to investigate the bacterial contamination rates of the reused and disposable ventilator systems, and the association between system disconnection and bacterial contamination of ventilator systems. Methods The enrolled intubated and mechanically ventilated patients used a conventional reused ventilator system and a disposable closed ventilator-suction system, respectively, for a week; specimens were then collected from the ventilator circuit systems to evaluate human and environmental bacterial contamination. The sputum specimens from patients were also analyzed in this study. Results The detection rate of bacteria in the conventional reused ventilator system was substantially higher than that in the disposable ventilator system. The inspiratory and expiratory limbs of the disposable closed ventilator-suction system had higher bacterial concentrations than the conventional reused ventilator system. The bacterial concentration in the heated humidifier of the reused ventilator system was significantly higher than that in the disposable ventilator system. Positive associations existed among the bacterial concentrations at different locations in the reused and disposable ventilator systems, respectively. The predominant bacteria identified in the reused and disposable ventilator systems included Acinetobacter spp., Bacillus cereus, Elizabethkingia spp., Pseudomonas spp., and Stenotrophomonas (Xan) maltophilia. Conclusions Both the reused and disposable ventilator systems had high bacterial contamination rates after one week of use. Disconnection of the ventilator systems should be avoided during system operation to decrease the risks of environmental pollution and human exposure, especially for the disposable ventilator system. Trial registration ClinicalTrials.gov PRS / NCT03359148 PMID:29547638
Schmithausen, Alexander J; Schiefler, Inga; Trimborn, Manfred; Gerlach, Katrin; Südekum, Karl-Heinz; Pries, Martin; Büscher, Wolfgang
2018-05-16
Extensive experimentation on individual animals in respiration chambers has already been carried out to evaluate the potential of dietary changes and opportunities to mitigate CH₄ emissions from ruminants. Although it is difficult to determine the air exchange rate of open barn spaces, measurements at the herd level should provide similarly reliable and robust results. The primary objective of this study was (1) to define a validity range (data classification criteria (DCC)) for the variables of wind velocity and wind direction during long-term measurements at barn level; and (2) to apply this validity range to a feeding trial in a naturally cross-flow ventilated dairy barn. The application of the DCC permitted quantification of CH₄ and NH₃ emissions during a feeding trial consisting of four periods. Differences between the control group (no supplement) and the experimental group fed a ration supplemented with condensed Acacia mearnsii tannins (CT) became apparent. Notably, CT concentrations of 1% and 3% of ration dry matter did not reduce CH₄ emissions. In contrast, NH₃ emissions decreased 34.5% when 3% CT was supplemented. The data confirm that quantification of trace gases in a naturally ventilated barn at the herd level is possible.
dos Reis, Helena França Correia; Almeida, Mônica Lajana Oliveira; da Silva, Mário Ferreira; Moreira, Julião Oliveira; Rocha, Mário de Seixas
2013-01-01
Objective To investigate the association between the rapid shallow breathing index and successful extubation in patients with traumatic brain injury. Methods This study was a prospective study conducted in patients with traumatic brain injury of both genders who underwent mechanical ventilation for at least two days and who passed a spontaneous breathing trial. The minute volume and respiratory rate were measured using a ventilometer, and the data were used to calculate the rapid shallow breathing index (respiratory rate/tidal volume). The dependent variable was the extubation outcome: reintubation after up to 48 hours (extubation failure) or not (extubation success). The independent variable was the rapid shallow breathing index measured after a successful spontaneous breathing trial. Results The sample comprised 119 individuals, including 111 (93.3%) males. The average age of the sample was 35.0±12.9 years old. The average duration of mechanical ventilation was 8.1±3.6 days. A total of 104 (87.4%) participants achieved successful extubation. No association was found between the rapid shallow breathing index and extubation success. Conclusion The rapid shallow breathing index was not associated with successful extubation in patients with traumatic brain injury. PMID:24213084
Eom, Joong Sik; Lee, Mi-Suk; Chun, Hee-Kyung; Choi, Hee Jung; Jung, Sun-Young; Kim, Yeon-Sook; Yoon, Seon Jin; Kwak, Yee Gyung; Oh, Gang-Bok; Jeon, Min-Hyok; Park, Sun-Young; Koo, Hyun-Sook; Ju, Young-Su; Lee, Jin Seo
2014-01-01
For prevention of ventilator-associated pneumonia (VAP), a bundle approach was applied to patients receiving mechanical ventilation in intensive care units. The incidence of VAP and the preventive efficacy of the VAP bundle were investigated. A quasi-experimental study was conducted in adult intensive care units of 6 university hospitals with similar VAP rates. We implemented the VAP bundle between March 2011 and June 2011, then compared the rate of VAP after implementation of the VAP bundle with the rate in the previous 8 months. Our ventilator bundle included head of bed elevation, peptic ulcer disease prophylaxis, deep venous thrombosis prophylaxis, and oral decontamination with chlorhexidine 0.12%. Continuous aspiration of subglottic secretions was an option. Implementation of the VAP bundle reduced the VAP rate from a mean of 4.08 cases per 1,000 ventilator-days to 1.16 cases per 1,000 ventilator-days. The incidence density ratio (rate) was 0.28 (95% confidence interval, 0.275-0.292). Implementing the appropriate VAP bundle significantly decreased the incidence of VAP in patients with mechanical ventilation. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Talbot, Thomas R; Carr, Devin; Parmley, C Lee; Martin, Barbara J; Gray, Barbara; Ambrose, Anna; Starmer, Jack
2015-11-01
The effectiveness of practice bundles on reducing ventilator-associated pneumonia (VAP) has been questioned. To implement a comprehensive program that included a real-time bundle compliance dashboard to improve compliance and reduce ventilator-associated complications. DESIGN Before-and-after quasi-experimental study with interrupted time-series analysis. SETTING Academic medical center. In 2007 a comprehensive institutional ventilator bundle program was developed. To assess bundle compliance and stimulate instant course correction of noncompliant parameters, a real-time computerized dashboard was developed. Program impact in 6 adult intensive care units (ICUs) was assessed. Bundle compliance was noted as an overall cumulative bundle adherence assessment, reflecting the percentage of time all elements were concurrently in compliance for all patients. The VAP rate in all ICUs combined decreased from 19.5 to 9.2 VAPs per 1,000 ventilator-days following program implementation (P<.001). Bundle compliance significantly increased (Z100 score of 23% in August 2007 to 83% in June 2011 [P<.001]). The implementation resulted in a significant monthly decrease in the overall ICU VAP rate of 3.28/1,000 ventilator-days (95% CI, 2.64-3.92/1,000 ventilator-days). Following the intervention, the VAP rate decreased significantly at a rate of 0.20/1,000 ventilator-days per month (95% CI, 0.14-0.30/1,000 ventilator-days per month). Among all adult ICUs combined, improved bundle compliance was moderately correlated with monthly VAP rate reductions (Pearson correlation coefficient, -0.32). A prevention program using a real-time bundle adherence dashboard was associated with significant sustained decreases in VAP rates and an increase in bundle compliance among adult ICU patients.
Characterizing the chaotic nature of ocean ventilation
NASA Astrophysics Data System (ADS)
MacGilchrist, Graeme A.; Marshall, David P.; Johnson, Helen L.; Lique, Camille; Thomas, Matthew
2017-09-01
Ventilation of the upper ocean plays an important role in climate variability on interannual to decadal timescales by influencing the exchange of heat and carbon dioxide between the atmosphere and ocean. The turbulent nature of ocean circulation, manifest in a vigorous mesoscale eddy field, means that pathways of ventilation, once thought to be quasi-laminar, are in fact highly chaotic. We characterize the chaotic nature of ventilation pathways according to a nondimensional "filamentation number," which estimates the reduction in filament width of a ventilated fluid parcel due to mesoscale strain. In the subtropical North Atlantic of an eddy-permitting ocean model, the filamentation number is large everywhere across three upper ocean density surfaces—implying highly chaotic ventilation pathways—and increases with depth. By mapping surface ocean properties onto these density surfaces, we directly resolve the highly filamented structure and confirm that the filamentation number captures its spatial variability. These results have implications for the spreading of atmospherically-derived tracers into the ocean interior.
Field study of air change and flow rate in six automobiles.
Knibbs, L D; de Dear, R J; Atkinson, S E
2009-08-01
For many people, a relatively large proportion of daily exposure to a multitude of pollutants may occur inside an automobile. A key determinant of exposure is the amount of outdoor air entering the cabin (i.e. air change or flow rate). We have quantified this parameter in six passenger vehicles ranging in age from 18 years to <1 year, at three vehicle speeds and under four different ventilation settings. Average infiltration into the cabin with all operable air entry pathways closed was between 1 and 33.1 air changes per hour (ACH) at a vehicle speed of 60 km/h, and between 2.6 and 47.3 ACH at 110 km/h, with these results representing the most (2005 Volkswagen Golf) and least air-tight (1989 Mazda 121) vehicles, respectively. Average infiltration into stationary vehicles parked outdoors varied between approximately 0 and 1.4 ACH and was moderately related to wind speed. Measurements were also performed under an air recirculation setting with low fan speed, while airflow rate measurements were conducted under two non-recirculate ventilation settings with low and high fan speeds. The windows were closed in all cases, and over 200 measurements were performed. The results can be applied to estimate pollutant exposure inside vehicles. There is increasing recognition of the often disproportionately large contribution of in-vehicle pollutant exposures to overall measures. This has highlighted the need for accurate and representative quantification of determinant factors to facilitate exposure estimation and mitigation. The ventilation rate in a vehicle cabin is a key parameter affecting the transfer of pollutants from outdoors to the cabin interior, and vice-versa. New data regarding this variable are presented here, and the results indicate substantial variability in outdoor air infiltration into vehicles of differing age. The efficacy of simple measures to reduce outdoor air infiltration into 'leaky' vehicles to increase occupant protection would be a worthwhile avenue of further research.
Association Between Noninvasive Ventilation and Mortality Among Older Patients With Pneumonia
Valley, Thomas S.; Walkey, Allan J.; Lindenauer, Peter K.; Wiener, Renda Soylemez; Cooke, Colin R.
2016-01-01
Objective Despite increasing use, evidence is mixed as to the appropriate use of noninvasive ventilation in patients with pneumonia. We aimed to determine the relationship between receipt of noninvasive ventilation and outcomes for patients with pneumonia in a real-world setting. Design, Setting, Patients We performed a retrospective cohort study of Medicare beneficiaries (aged > 64 yr) admitted to 2,757 acute-care hospitals in the United States with pneumonia, who received mechanical ventilation from 2010 to 2011. Exposures Noninvasive ventilation versus invasive mechanical ventilation. Measurement and Main Results The primary outcome was 30-day mortality with Medicare reimbursement as a secondary outcome. To account for unmeasured confounding associated with noninvasive ventilation use, an instrumental variable was used—the differential distance to a high noninvasive ventilation use hospital. All models were adjusted for patient and hospital characteristics to account for measured differences between groups. Among 65,747 Medicare beneficiaries with pneumonia who required mechanical ventilation, 12,480 (19%) received noninvasive ventilation. Patients receiving noninvasive ventilation were more likely to be older, male, white, rural-dwelling, have fewer comorbidities, and were less likely to be acutely ill as measured by organ failures. Results of the instrumental variable analysis suggested that, among marginal patients, receipt of noninvasive ventilation was not significantly associated with differences in 30-day mortality when compared with invasive mechanical ventilation (54% vs 55%; p = 0.92; 95% CI of absolute difference, –13.8 to 12.4) but was associated with significantly lower Medicare spending ($18,433 vs $27,051; p = 0.02). Conclusions Among Medicare beneficiaries hospitalized with pneumonia who received mechanical ventilation, noninvasive ventilation use was not associated with a real-world mortality benefit. Given the wide CIs, however, substantial harm associated with noninvasive ventilation could not be excluded. The use of noninvasive ventilation for patients with pneumonia should be cautioned, but targeted enrollment of marginal patients with pneumonia could enrich future randomized trials. PMID:27749319
Sharpe, Tim; Farren, Paul; Howieson, Stirling; Tuohy, Paul; McQuillan, Jonathan
2015-07-21
The need to reduce carbon emissions and fuel poverty has led to increased building envelope air tightness, intended to reduce uncontrolled ventilation heat losses. Ventilation strategies in dwellings still allow the use of trickle ventilators in window frames for background ventilation. The extent to which this results in "healthy" Indoor Air Quality (IAQ) in recently constructed dwellings was a concern of regulators in Scotland. This paper describes research to explore this. First a review of literature was conducted, then data on occupant interactions with ventilation provisions (windows, doors, trickle vents) gathered through an interview-based survey of 200 recently constructed dwellings, and measurements made on a sample of 40 of these. The main measured parameter discussed here is CO2 concentration. It was concluded after the literature review that 1000 ppm absolute was a reasonable threshold to use for "adequate" ventilation. The occupant survey found that there was very little occupant interaction with the trickle ventilators e.g., in bedrooms 63% were always closed, 28% always open, and in only 9% of cases occupants intervened to make occasional adjustments. In the measured dwellings average bedroom CO2 levels of 1520 ppm during occupied (night time) hours were observed. Where windows were open the average bedroom CO2 levels were 972 ppm. With windows closed, the combination of "trickle ventilators open plus doors open" gave an average of 1021 ppm. "Trickle ventilators open" gave an average of 1571 ppm. All other combinations gave averages of 1550 to 2000 ppm. Ventilation rates and air change rates were estimated from measured CO2 levels, for all dwellings calculated ventilation rate was less than 8 L/s/p, in 42% of cases calculated air change rate was less than 0.5 ach. It was concluded that trickle ventilation as installed and used is ineffective in meeting desired ventilation rates, evidenced by high CO2 levels reported across the sampled dwellings. Potential implications of the results are discussed.
46 CFR 153.316 - Special cargo pumproom ventilation rate.
Code of Federal Regulations, 2013 CFR
2013-10-01
... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Handling Space Ventilation § 153.316 Special cargo pumproom ventilation rate. When Table 1...
46 CFR 153.316 - Special cargo pumproom ventilation rate.
Code of Federal Regulations, 2012 CFR
2012-10-01
... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Handling Space Ventilation § 153.316 Special cargo pumproom ventilation rate. When Table 1...
46 CFR 153.316 - Special cargo pumproom ventilation rate.
Code of Federal Regulations, 2011 CFR
2011-10-01
... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Handling Space Ventilation § 153.316 Special cargo pumproom ventilation rate. When Table 1...
46 CFR 153.316 - Special cargo pumproom ventilation rate.
Code of Federal Regulations, 2014 CFR
2014-10-01
... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Handling Space Ventilation § 153.316 Special cargo pumproom ventilation rate. When Table 1...
46 CFR 153.316 - Special cargo pumproom ventilation rate.
Code of Federal Regulations, 2010 CFR
2010-10-01
... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Handling Space Ventilation § 153.316 Special cargo pumproom ventilation rate. When Table 1...
Samransamruajkit, Rujipat; Jirapaiboonsuk, Suree; Siritantiwat, Sirirush; Tungsrijitdee, Ornanong; Deerojanawong, Jitladda; Sritippayawan, Suchada; Prapphal, Nuanchan
2010-03-01
Ventilator-associated pneumonia (VAP) is associated with significant morbidity and mortality in pediatric intensive care unit (PICU). Our purpose was to evaluate the effects of ventilator circuit change on the rate of VAP in the PICU. A prospective randomized controlled trial was conducted at a university hospital PICU. Children (younger than 18 years) who received mechanical ventilation from December 2006 to November 2007 were randomly assigned to receive ventilator circuit changes every 3 or 7 days. Of 176 patients, 88 were assigned to receive ventilator circuit every 3 days and 88 patients had a change weekly. The rate of VAP was 13.9/1000 ventilator days for the 3-day circuit change (n = 12) vs 11.5/1000 ventilator days (n = 10) for the 7-day circuit change (odds ratio, 0.8; confidence interval, 0.3-1.9; P = .6). There was a trend toward decreased PICU stay and mortality rate in 7-day change group compared to 3-day change group but did not reach statistical significance. Furthermore, switching from a 3-day to a 7-day change policy could save costs up to US $22,000/y. The 7-day ventilator circuit change did not contribute to increased rates of VAP in our PICU. Thus, it may be used as a guide to save workload and supply costs. Crown Copyright 2010. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patton, T; Du, K; Bayouth, J
Purpose: Ventilation change caused by radiation therapy (RT) can be predicted using four-dimensional computed tomography (4DCT) and image registration. This study tested the dependency of predicted post-RT ventilation on effort correction and pre-RT lung function. Methods: Pre-RT and 3 month post-RT 4DCT images were obtained for 13 patients. The 4DCT images were used to create ventilation maps using a deformable image registration based Jacobian expansion calculation. The post-RT ventilation maps were predicted in four different ways using the dose delivered, pre-RT ventilation, and effort correction. The pre-RT ventilation and effort correction were toggled to determine dependency. The four different predictedmore » ventilation maps were compared to the post-RT ventilation map calculated from image registration to establish the best prediction method. Gamma pass rates were used to compare the different maps with the criteria of 2mm distance-to-agreement and 6% ventilation difference. Paired t-tests of gamma pass rates were used to determine significant differences between the maps. Additional gamma pass rates were calculated using only voxels receiving over 20 Gy. Results: The predicted post-RT ventilation maps were in agreement with the actual post-RT maps in the following percentage of voxels averaged over all subjects: 71% with pre-RT ventilation and effort correction, 69% with no pre-RT ventilation and effort correction, 60% with pre-RT ventilation and no effort correction, and 58% with no pre-RT ventilation and no effort correction. When analyzing only voxels receiving over 20 Gy, the gamma pass rates were respectively 74%, 69%, 65%, and 55%. The prediction including both pre- RT ventilation and effort correction was the only prediction with significant improvement over using no prediction (p<0.02). Conclusion: Post-RT ventilation is best predicted using both pre-RT ventilation and effort correction. This is the only prediction that provided a significant improvement on agreement. Research support from NIH grants CA166119 and CA166703, a gift from Roger Koch, and a Pilot Grant from University of Iowa Carver College of Medicine.« less
Póvoa, Pedro
2017-01-01
Ventilator-associated pneumonia (VAP) is a common infection in intensive care units (ICUs) but its clinical definition is neither sensitive nor specific and lacks accuracy and objectivity. New defining criteria were proposed in 2013 by the National Healthcare Safety Network (NHSN) in order to more accurately conduct surveillance and track prevention progress. Although there is a consistent trend towards a decrease in VAP incidence during the last decade, significant differences in VAP rates have been reported and are persistently lower in NHSN and other American reports (0.0 to 4.4 VAP per 1,000 ventilator-days in 2012) compared to the European Centre for Disease Prevention and Control (ECDC) data (10 VAP per 1,000 ventilator-days in 2014). In the United States, VAP has been proposed as an indicator of quality of care in public reporting, and the threat of financial penalties for this diagnosis has put pressure on hospitals to minimize VAP rates that may lead to artificial lower values, independently of patient care. Although prevention bundles may contribute for encouraging reductions in VAP incidence, both pathophysiologic and epidemiologic factors preclude a zero-VAP rate. It would be expected from the trend of reduction of VAP incidence that the consumption of antibiotics would also decrease in particular in those hospitals with lowest VAP rates. However, ICU reports show a steadily use of antibiotics for nosocomial pneumonia in 15% of patients and both ECDC and NHSN data on antibiotic consumption showed no significant trend. Knowledge of bacterial epidemiology and resistance profiles for each ICU has great relevance in order to understand trends of antibiotic use. The new NHSN criteria provide a more objective and quantitative data based VAP definition, including an antibiotic administration criterion, allowing, in theory, a more comprehensive assessment and a reportable benchmark of the observed VAP and antibiotic consumption variability. PMID:29264367
Nora, David; Póvoa, Pedro
2017-11-01
Ventilator-associated pneumonia (VAP) is a common infection in intensive care units (ICUs) but its clinical definition is neither sensitive nor specific and lacks accuracy and objectivity. New defining criteria were proposed in 2013 by the National Healthcare Safety Network (NHSN) in order to more accurately conduct surveillance and track prevention progress. Although there is a consistent trend towards a decrease in VAP incidence during the last decade, significant differences in VAP rates have been reported and are persistently lower in NHSN and other American reports (0.0 to 4.4 VAP per 1,000 ventilator-days in 2012) compared to the European Centre for Disease Prevention and Control (ECDC) data (10 VAP per 1,000 ventilator-days in 2014). In the United States, VAP has been proposed as an indicator of quality of care in public reporting, and the threat of financial penalties for this diagnosis has put pressure on hospitals to minimize VAP rates that may lead to artificial lower values, independently of patient care. Although prevention bundles may contribute for encouraging reductions in VAP incidence, both pathophysiologic and epidemiologic factors preclude a zero-VAP rate. It would be expected from the trend of reduction of VAP incidence that the consumption of antibiotics would also decrease in particular in those hospitals with lowest VAP rates. However, ICU reports show a steadily use of antibiotics for nosocomial pneumonia in 15% of patients and both ECDC and NHSN data on antibiotic consumption showed no significant trend. Knowledge of bacterial epidemiology and resistance profiles for each ICU has great relevance in order to understand trends of antibiotic use. The new NHSN criteria provide a more objective and quantitative data based VAP definition, including an antibiotic administration criterion, allowing, in theory, a more comprehensive assessment and a reportable benchmark of the observed VAP and antibiotic consumption variability.
Fifty Years of Research in ARDS. Respiratory Mechanics in Acute Respiratory Distress Syndrome.
Henderson, William R; Chen, Lu; Amato, Marcelo B P; Brochard, Laurent J
2017-10-01
Acute respiratory distress syndrome is a multifactorial lung injury that continues to be associated with high levels of morbidity and mortality. Mechanical ventilation, although lifesaving, is associated with new iatrogenic injury. Current best practice involves the use of small Vt, low plateau and driving pressures, and high levels of positive end-expiratory pressure. Collectively, these interventions are termed "lung-protective ventilation." Recent investigations suggest that individualized measurements of pulmonary mechanical variables rather than population-based ventilation prescriptions may be used to set the ventilator with the potential to improve outcomes beyond those achieved with standard lung protective ventilation. This review outlines the measurement and application of clinically applicable pulmonary mechanical concepts, such as plateau pressures, driving pressure, transpulmonary pressures, stress index, and measurement of strain. In addition, the concept of the "baby lung" and the utility of dynamic in addition to static measures of pulmonary mechanical variables are discussed.
Mahmoodpoor, Ata; Hamishehkar, Hadi; Hamidi, Masoud; Shadvar, Kamran; Sanaie, Sarvin; Golzari, Samad Ej; Khan, Zahid Hussain; Nader, Nader D
2017-04-01
Endotracheal tube placement is necessary for the control of the airway in patients who are mechanically ventilated. However, prolonged duration of endotracheal tube placement contributes to the development of ventilator-associated pneumonias (VAPs). The aim of this study was to evaluate whether subglottic suctioning using TaperGuard EVAC tubes was effective in decreasing the frequency of VAP. A total of 276 mechanically ventilated patients for more than 72 hours were randomly assigned to group E (EVAC tube) and group C (conventional tube). All patients received routine care including VAP prevention measures during their intensive care unit stay. In group E, subglottic suctioning was performed every 6 hours. Outcome variables included incidence VAP, intensive care unit length of stay, and mortality. Frequency of intraluminal suction, mechanical ventilation-free days, reintubation, the ratio of arterial oxygen partial pressure to fractional inspired oxygen and mortality rate were similar between the 2 groups (P > .05). The mean cuff pressure in group E was significantly less than that in group C (P < .001). Ventilator-associated pneumonia was significantly less in group E compared with group C (P = .015). The use of intermittent subglottic secretion suctioning was associated with a significant decrease in the incidence of the VAP in critically ill patients. However, larger multicenter trials are required to arrive at a concrete decision on routine usage of TaperGuard tubes in critical care settings. Published by Elsevier Inc.
Rhein, Monika; Steinfeldt, Reiner; Kieke, Dagmar; Stendardo, Ilaria; Yashayaev, Igor
2017-09-13
Ventilation of Labrador Sea Water (LSW) receives ample attention because of its potential relation to the strength of the Atlantic Meridional Overturning Circulation (AMOC). Here, we provide an overview of the changes of LSW from observations in the Labrador Sea and from the southern boundary of the subpolar gyre at 47° N. A strong winter-time atmospheric cooling over the Labrador Sea led to intense and deep convection, producing a thick and dense LSW layer as, for instance, in the early to mid-1990s. The weaker convection in the following years mostly ventilated less dense LSW vintages and also reduced the supply of oxygen. As a further consequence, the rate of uptake of anthropogenic carbon by LSW decreased between the two time periods 1996-1999 and 2007-2010 in the western subpolar North Atlantic. In the eastern basins, the rate of increase in anthropogenic carbon became greater due to the delayed advection of LSW that was ventilated in previous years. Starting in winter 2013/2014 and prevailing at least into winter 2015/2016, production of denser and more voluminous LSW resumed. Increasing oxygen signals have already been found in the western boundary current at 47° N. On decadal and shorter time scales, anomalous cold atmospheric conditions over the Labrador Sea lead to an intensification of convection. On multi-decadal time scales, the 'cold blob' in the subpolar North Atlantic projected by climate models in the next 100 years is linked to a weaker AMOC and weaker convection (and thus deoxygenation) in the Labrador Sea.This article is part of the themed issue 'Ocean ventilation and deoxygenation in a warming world'. © 2017 The Author(s).
Barry, Rachel A; Fink, Daniel S; Pourciau, Dusty Cole; Hayley, Kasey; Lanius, Rachael; Hayley, Schuylor; Sims, Eddy; McWhorter, Andrew J
2017-09-01
Objective Jet ventilation has been used for >30 years as an anesthetic modality for laryngotracheal surgery. Concerns exist over increased risk with elevated body mass index (BMI). We reviewed our experience using jet ventilation for laryngotracheal stenosis to assess for complication rates with substratification by BMI. Study Design Case series with chart review. Setting Tertiary care center. Subjects and Methods A total of 126 procedures with jet ventilation were identified from October 2006 to December 2014. Complications were recorded, including intubation, unplanned admission, readmission, dysphonia, oral trauma, pneumothorax, pneumomediastinum, and tracheostomy. Lowest intraoperative oxygen saturation and maximum end-tidal CO 2 (ETCO 2 ) levels were recorded. Results Among 126 patients, 43, 77, and 6 had BMIs of <25, 25-35, and 36-45, respectively. In the BMI <25 group, there was 1 unplanned intubation. Mean maximum ETCO 2 was 36.51 with no hypoxemia observed. In the BMI 25-35 group, 2 patients required intubation, and 1 sustained minor oral trauma. The mean maximum ETCO 2 was 38.85, with 4 patients having oxygen saturation <90%. In the BMI 36-45 group, 2 patients required intubation. The mean maximum ETCO 2 was 41 with no hypoxemia observed. BMI and length of stenosis were statistically significant variables associated with incidence of intraoperative intubation. Conclusion Increased BMI was associated with an increase in highest ETCO 2 intraoperatively. However, this was not associated with an increase in major complications. Jet ventilation was performed without significant adverse events in this sample, and it is a viable option if used with an experienced team in the management of laryngotracheal stenosis.
NASA Astrophysics Data System (ADS)
Rhein, Monika; Steinfeldt, Reiner; Kieke, Dagmar; Stendardo, Ilaria; Yashayaev, Igor
2017-08-01
Ventilation of Labrador Sea Water (LSW) receives ample attention because of its potential relation to the strength of the Atlantic Meridional Overturning Circulation (AMOC). Here, we provide an overview of the changes of LSW from observations in the Labrador Sea and from the southern boundary of the subpolar gyre at 47° N. A strong winter-time atmospheric cooling over the Labrador Sea led to intense and deep convection, producing a thick and dense LSW layer as, for instance, in the early to mid-1990s. The weaker convection in the following years mostly ventilated less dense LSW vintages and also reduced the supply of oxygen. As a further consequence, the rate of uptake of anthropogenic carbon by LSW decreased between the two time periods 1996-1999 and 2007-2010 in the western subpolar North Atlantic. In the eastern basins, the rate of increase in anthropogenic carbon became greater due to the delayed advection of LSW that was ventilated in previous years. Starting in winter 2013/2014 and prevailing at least into winter 2015/2016, production of denser and more voluminous LSW resumed. Increasing oxygen signals have already been found in the western boundary current at 47° N. On decadal and shorter time scales, anomalous cold atmospheric conditions over the Labrador Sea lead to an intensification of convection. On multi-decadal time scales, the `cold blob' in the subpolar North Atlantic projected by climate models in the next 100 years is linked to a weaker AMOC and weaker convection (and thus deoxygenation) in the Labrador Sea. This article is part of the themed issue 'Ocean ventilation and deoxygenation in a warming world'.
USDA-ARS?s Scientific Manuscript database
Increasing broiler house size and ventilation capacity have resulted in increased light ingress through ventilation system component apertures. The effective photoperiod for broilers may create local increases in light intensity, which may also impact broiler’ body homeostasis. The objective of this...
Ventilation-associated pneumonia after intubation in the prehospital or the emergency unit.
Decelle, Lydie; Thys, Frédéric; Zech, Francis; Verschuren, Franck
2013-02-01
The aim of the study was to evaluate the prevalence and the risk factors of ventilation-associated pneumonia (VAP) for out-of-hospital or in the emergency department intubated patients. This was a retrospective descriptive study. All intubated adults subsequently admitted to the ICU over 1-year period were included. Among 75 patients, 15 patients developed VAP (20%; 95% CI 12-31%). A multivariate analysis revealed three variables independently associated with VAP: cardiorespiratory arrest as the reason of intubation (P=0.001), out-of-hospital as the location of intubation (P=0.011), and clinical macroaspiration as clinical characteristic at the time of intubation (P=0.024). Death rate was 17% and was not significantly higher for patients with VAP (P=0.9; 95% CI 0.32-4.95%). Emergency care workers should be aware of the potential 20% occurrence of VAP when they intubate and ventilate a patient. Preventive strategies, which have been proven effective in ICUs, should be implemented in the emergency setting.
Emhofer, Waltraud; Lichtenegger, Klaus; Haslinger, Walter; Hofbauer, Hermann; Schmutzer-Roseneder, Irene; Aigenbauer, Stefan; Lienhard, Martin
2015-01-01
Wood pellets have been reported to emit toxic gaseous emissions during transport and storage. Carbon monoxide (CO) emission, due to the high toxicity of the gas and the possibility of it being present at high levels, is the most imminent threat to be considered before entering a pellet storage facility. For small-scale (<30 tons storage capacity) residential pellet storage facilities, ventilation, preferably natural ventilation utilizing already existing openings, has become the most favored solution to overcome the problem of high CO concentrations. However, there is little knowledge on the ventilation rates that can be reached and thus on the effectiveness of such measures. The aim of the study was to investigate ventilation rates for a specific small-scale pellet storage system depending on characteristic temperature differences. Furthermore, the influence of the implementation of a chimney and the influence of cross-ventilation on the ventilation rates were investigated. The air exchange rates observed in the experiments ranged between close to zero and up to 8 m(3) h(-1), depending largely on the existing temperature differences and the existence of cross-ventilation. The results demonstrate that implementing natural ventilation is a possible measure to enhance safety from CO emissions, but not one without limitations. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Effect of varying the pressurisation rate during noninvasive pressure support ventilation.
Prinianakis, G; Delmastro, M; Carlucci, A; Ceriana, P; Nava, S
2004-02-01
The aim of the study was to assess the effects of varying the pressurisation rate during noninvasive pressure support ventilation on patients' breathing pattern, inspiratory effort, arterial blood gases, tolerance to ventilation and amount of air leakage. A total of 15 chronic obstructive pulmonary disease patients recovering from an acute episode of hypercapnic acute respiratory failure were studied during four randomised trials with different levels of pressurisation rate. No significant changes were observed in breathing pattern and arterial blood gases between the different runs. The pressure time product of the diaphragm, an estimate of its metabolic consumption, was significantly lower with all pressurisation rates than with spontaneous breathing, but was significantly lowest with the fastest rate. However, air leak, assessed by the ratio between expired and inspired tidal volumes, increased and the patients' tolerance of ventilation, measured using a standardised scale, was significantly poorer with the fastest pressurisation rate. In chronic obstructive pulmonary disease patients recovering from an episode of acute hypercapnic respiratory failure and ventilated with noninvasive pressure support ventilation, different pressurisation rates resulted in different reductions in the pressure time product of the diaphragm; this reduction was greater with the fastest rate, but was accompanied by significant air leaks and poor tolerance.
Carbon dioxide clearance in rabbits during expiratory phase intratracheal pulmonary ventilation.
Meyappan, Raju T; Raszynski, Andre; Bohorquez, Jorge; Totapally, Balagangadhar R; Koul, Pulin B; Norozian, Faraz M; Valcourt, Karl; Torbati, Dan
2007-01-01
The purpose of this study was to compare the efficacy of CO2 removal during conventional mechanical ventilation (CMV) with and without expiratory phase intratracheal pulmonary ventilation (expiratory ITPV or Exp-ITPV); and to compare CO2 clearance during Exp-ITPV, in pressure-controlled ventilation (PCV) and in volume-controlled ventilation (VCV) modes. Seven anesthetized rabbits were tracheotomized and intubated using a 4 mm endotracheal tube. Venous and arterial lines were established. The rabbits were paralyzed, mechanically ventilated, and ventilation parameters were adjusted to achieve baseline arterial hypercapnia. Animals were then ventilated during 30-minute trials of CMV and Exp-ITPV, in both PCV and VCV modes. A custom-built, microprocessor-controlled solenoid valve was used to limit ITPV gas flow to the expiratory phase. Proximal and carinal airway pressures and hemodynamic variables were continuously recorded, and arterial blood gases were analyzed at the end of each trial. Exp-ITPV, as compared with CMV, reduced arterial PCO2 by 12% and 21% in PCV and VCV modes, respectively (p < 0.02 and p < 0.001; one-sided paired t test), without significant changes in other cardiorespiratory variables. In conclusion, Exp-ITPV is more effective than CMV in clearing CO2 through a small endotracheal tube. Exp-ITPV is also more effective in VCV mode than PCV mode.
Li, Shengli; Wang, Xu; Li, Shoujun; Yan, Jun
2013-08-01
Acute respiratory distress syndrome (ARDS) in children after open heart surgery, although uncommon, can be a significant source of morbidity. Because high-frequency oscillatory ventilation (HFOV) had been used successfully with pediatric patients who had no congenital heart defects, this therapy was used in our unit. This report aims to describe a single-center experience with HFOV in the management of ARDS after open heart surgery with respect to mortality. This retrospective clinical study was conducted in a pediatric intensive care unit. From October 2008 to August 2012, 64 of 10,843 patients with refractory ARDS who underwent corrective surgery at our institution were ventilated with HFOV. Patients with significant uncorrected residual lesions were not included. No interventions were performed. The patients were followed up until hospital discharge. The main outcome measure was survival to hospital discharge. Severe ARDS was defined as acute-onset pulmonary failure with bilateral pulmonary infiltrates and an oxygenation index (OI) higher than 13 despite maximal ventilator settings. The indication for HFOV was acute severe ARDS unresponsive to optimal conventional treatment. The variables recorded and subjected to multivariate analysis were patient demographics, underlying disease, clinical data, and ventilator parameters and their association with hospital mortality. Nearly 10,843 patients underwent surgery during the study period, and the ARDS incidence rate was 0.76 % (83/10,843), with 64 patients (77 %, 64/83) receiving HFOV. No significant changes in systemic or central venous pressure were associated with initiation and maintenance of HFOV. The complications during HFOV included pneumothorax for 22 patients. The overall in-hospital mortality rate was 39 % (25/64). Multiple regression analyses indicated that pulmonary hypertension and recurrent respiratory tract infections (RRTIs) before surgery were independent predictors of in-hospital mortality. The findings show that HFOV is an effective and safe method for ventilating severe ARDS patients after corrective cardiac surgery. Pulmonary hypertension and RRTIs before surgery were risk factors for in-hospital mortality.
Park, Sang O; Shin, Dong Hyuk; Baek, Kwang Je; Hong, Dae Young; Kim, Eun Jung; Kim, Sang Chul; Lee, Kyeong Ryong
2013-03-01
This is the first study to identify the factors associated with hyperventilation during actual cardiopulmonary resuscitation (CPR) in the emergency department (ED). All CPR events in the ED were recorded by video from April 2011 to December 2011. The following variables were analysed using review of the recorded CPR data: ventilation rate (VR) during each minute and its associated factors including provider factors (experience, advanced cardiovascular life support (ACLS) certification), clinical factors (auscultation to confirm successful intubation, suctioning, and comments by the team leader) and time factors (time or day of CPR). Fifty-five adult CPR cases including a total of 673 min sectors were analysed. The higher rates of hyperventilation (VR>10/min) were delivered by inexperienced (53.3% versus 14.2%) or uncertified ACLS provider (52.2% versus 10.8%), during night time (61.0 versus 34.5%) or weekend CPR (53.1% versus 35.6%) and when auscultation to confirm successful intubation was performed (93.5% versus 52.8%) than not (all p<0.0001). However, experienced (25.3% versus 29.7%; p=0.448) or certified ACLS provider (20.6% versus 31.3%; p<0.0001) could not deliver high rate of proper ventilation (VR 8-10/min). Comment by the team leader was most strongly associated with the proper ventilation (odds ratio 7.035, 95% confidence interval 4.512-10.967). Hyperventilation during CPR was associated with inexperienced or uncertified ACLS provider, auscultation to confirm intubation, and night time or weekend CPR. And to deliver proper ventilation, comments by the team leader should be given regardless of providers' expert level. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Validation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities.
Villar, Rodrigo; Beltrame, Thomas; Hughson, Richard L
2015-10-01
We tested the validity of the Hexoskin wearable vest to monitor heart rate (HR), breathing rate (BR), tidal volume (VT), minute ventilation, and hip motion intensity (HMI) in comparison with laboratory standard devices during lying, sitting, standing, and walking. Twenty healthy young volunteers participated in this study. First, participants walked 6 min on a treadmill at speeds of 1, 3, and 4.5 km/h followed by increasing treadmill grades until 80% of their predicted maximal heart rate. Second, lying, sitting, and standing tasks were performed (5 min each) followed by 6 min of treadmill walking at 80% of their ventilatory threshold. Analysis of each individual's mean values under each resting or exercise condition by the 2 measurement systems revealed low coefficient of variation and high intraclass correlation values for HR, BR, and HMI. The Bland-Altman results from HR, BR, and HMI indicated no deviation of the mean value from zero and relatively small variability about the mean. VT and minute ventilation were provided in arbitrary units by the Hexoskin device; however, relative magnitude of change from Hexoskin closely tracked the laboratory standard method. Hexoskin presented low variability, good agreement, and consistency. The Hexoskin wearable vest was a valid and consistent tool to monitor activities typical of daily living such as different body positions (lying, sitting, and standing) and various walking speeds.
Sandoval Moreno, L M; Casas Quiroga, I C; Wilches Luna, E C; García, A F
2018-02-02
To evaluate the efficacy of respiratory muscular training in the weaning of mechanical ventilation and respiratory muscle strength in patients on mechanical ventilation of 48hours or more. Randomized controlled trial of parallel groups, double-blind. Ambit: Intensive Care Unit of a IV level clinic in the city of Cali. 126 patients in mechanical ventilation for 48hours or more. The experimental group received daily a respiratory muscle training program with treshold, adjusted to 50% of maximal inspiratory pressure, additional to standard care, conventional received standard care of respiratory physiotherapy. MAIN INTEREST VARIABLES: weaning of mechanical ventilation. Other variables evaluated: respiratory muscle strength, requirement of non-invasive mechanical ventilation and frequency of reintubation. intention-to-treat analysis was performed with all variables evaluated and analysis stratified by sepsis condition. There were no statistically significant differences in the median weaning time of the MV between the groups or in the probability of extubation between groups (HR: 0.82 95% CI: 0.55-1.20 P=.29). The maximum inspiratory pressure was increased in the experimental group on average 9.43 (17.48) cmsH20 and in the conventional 5.92 (11.90) cmsH20 (P=.48). The difference between the means of change in maximal inspiratory pressure was 0.46 (P=.83 95%CI -3.85 to -4.78). respiratory muscle training did not demonstrate efficacy in the reduction of the weaning period of mechanical ventilation nor in the increase of respiratory muscle strength in the study population. Registered study at ClinicalTrials.gov (NCT02469064). Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.
Leopold, Jan Hendrik; Abu-Hanna, Ameen; Colombo, Camilla; Sterk, Peter J.; Schultz, Marcus J.; Bos, Lieuwe D. J.
2016-01-01
Introduction: Continuous breath analysis by electronic nose (eNose) technology in the intensive care unit (ICU) may be useful in monitoring (patho) physiological changes. However, the application of breath monitoring in a non-controlled clinical setting introduces noise into the data. We hypothesized that the sensor signal is influenced by: (1) humidity in the side-stream; (2) patient-ventilator disconnections and the nebulization of medication; and (3) changes in ventilator settings and the amount of exhaled CO2. We aimed to explore whether the aforementioned factors introduce noise into the signal, and discuss several approaches to reduce this noise. Methods: Study in mechanically-ventilated ICU patients. Exhaled breath was monitored using a continuous eNose with metal oxide sensors. Linear (mixed) models were used to study hypothesized associations. Results: In total, 1251 h of eNose data were collected. First, the initial 15 min of the signal was discarded. There was a negative association between humidity and Sensor 1 (Fixed-effect β: −0.05 ± 0.002) and a positive association with Sensors 2–4 (Fixed-effect β: 0.12 ± 0.001); the signal was corrected for this noise. Outliers were most likely due to noise and therefore removed. Sensor values were positively associated with end-tidal CO2, tidal volume and the pressure variables. The signal was corrected for changes in these ventilator variables after which the associations disappeared. Conclusion: Variations in humidity, ventilator disconnections, nebulization of medication and changes of ventilator settings indeed influenced exhaled breath signals measured in ventilated patients by continuous eNose analysis. We discussed several approaches to reduce the effects of these noise inducing variables. PMID:27556467
Energy and cost associated with ventilating office buildings in a tropical climate.
Rim, Donghyun; Schiavon, Stefano; Nazaroff, William W
2015-01-01
Providing sufficient amounts of outdoor air to occupants is a critical building function for supporting occupant health, well-being and productivity. In tropical climates, high ventilation rates require substantial amounts of energy to cool and dehumidify supply air. This study evaluates the energy consumption and associated cost for thermally conditioning outdoor air provided for building ventilation in tropical climates, considering Singapore as an example locale. We investigated the influence on energy consumption and cost of the following factors: outdoor air temperature and humidity, ventilation rate (L/s per person), indoor air temperature and humidity, air conditioning system coefficient of performance (COP), and cost of electricity. Results show that dehumidification of outdoor air accounts for more than 80% of the energy needed for building ventilation in Singapore's tropical climate. Improved system performance and/or a small increase in the indoor temperature set point would permit relatively large ventilation rates (such as 25 L/s per person) at modest or no cost increment. Overall, even in a thermally demanding tropical climate, the energy cost associated with increasing ventilation rate up to 25 L/s per person is less than 1% of the wages of an office worker in an advanced economy like Singapore's. This result implies that the benefits of increasing outdoor air ventilation rate up to 25 L/s per person--which is suggested to provide for productivity increases, lower sick building syndrome symptom prevalence, and reduced sick leave--can be much larger than the incremental cost of ventilation.
Increased ventilatory variability and complexity in patients with hyperventilation disorder.
Bokov, Plamen; Fiamma, Marie-Noëlle; Chevalier-Bidaud, Brigitte; Chenivesse, Cécile; Straus, Christian; Similowski, Thomas; Delclaux, Christophe
2016-05-15
It has been hypothesized that hyperventilation disorders could be characterized by an abnormal ventilatory control leading to enhanced variability of resting ventilation. The variability of tidal volume (VT) often depicts a nonnormal distribution that can be described by the negative slope characterizing augmented breaths formed by the relationship between the probability density distribution of VT and VT on a log-log scale. The objectives of this study were to describe the variability of resting ventilation [coefficient of variation (CV) of VT and slope], the stability in respiratory control (loop, controller and plant gains characterizing ventilatory-chemoresponsiveness interactions) and the chaotic-like dynamics (embedding dimension, Kappa values characterizing complexity) of resting ventilation in patients with a well-defined dysfunctional breathing pattern characterized by air hunger and constantly decreased PaCO2 during a cardiopulmonary exercise test. Compared with 14 healthy subjects with similar anthropometrics, 23 patients with hyperventilation were characterized by increased variability of resting tidal ventilation (CV of VT median [interquartile]: 26% [19-35] vs. 36% [28-48], P = 0.020; slope: -6.63 [-7.65; -5.36] vs. -3.88 [-5.91; -2.66], P = 0.004) that was not related to increased chemical drive (loop gain: 0.051 [0.039-0.221] vs. 0.044 [0.012-0.087], P = 0.149) but that was related to an increased ventilatory complexity (Kappa values, P < 0.05). Plant gain was decreased in patients and correlated with complexity (with Kappa 5 - degree 5: Rho = -0.48, P = 0.006). In conclusion, well-defined patients suffering from hyperventilation disorder are characterized by increased variability of their resting ventilation due to increased ventilatory complexity with stable ventilatory-chemoresponsiveness interactions. Copyright © 2016 the American Physiological Society.
2012-01-01
Background Ventilator-associated pneumonia (VAP) is a common infection in the intensive care unit (ICU) and associated with a high mortality. Methods A quasi-experimental study was conducted in a medical-surgical ICU. Multiple interventions to optimize VAP prevention were performed from October 2008 to December 2010. All of these processes, including the Institute for Healthcare Improvement’s (IHI) ventilator bundle plus oral decontamination with chlorhexidine and continuous aspiration of subglottic secretions (CASS), were adopted for patients undergoing mechanical ventilation. Results We evaluated a total of 21,984 patient-days, and a total of 6,052 ventilator-days (ventilator utilization rate of 0.27). We found VAP rates of 1.3 and 2.0 per 1,000 ventilator days respectively in 2009 and 2010, achieving zero incidence of VAP several times during 12 months, whenever VAP bundle compliance was over 90%. Conclusion These results suggest that it is possible to reduce VAP rates to near zero and sustain these rates, but it requires a complex process involving multiple performance measures and interventions that must be permanently monitored. PMID:23020101
Caserta, Raquel A; Marra, Alexandre R; Durão, Marcelino S; Silva, Cláudia Vallone; Pavao dos Santos, Oscar Fernando; Neves, Henrique Sutton de Sousa; Edmond, Michael B; Timenetsky, Karina Tavares
2012-09-29
Ventilator-associated pneumonia (VAP) is a common infection in the intensive care unit (ICU) and associated with a high mortality. A quasi-experimental study was conducted in a medical-surgical ICU. Multiple interventions to optimize VAP prevention were performed from October 2008 to December 2010. All of these processes, including the Institute for Healthcare Improvement's (IHI) ventilator bundle plus oral decontamination with chlorhexidine and continuous aspiration of subglottic secretions (CASS), were adopted for patients undergoing mechanical ventilation. We evaluated a total of 21,984 patient-days, and a total of 6,052 ventilator-days (ventilator utilization rate of 0.27). We found VAP rates of 1.3 and 2.0 per 1,000 ventilator days respectively in 2009 and 2010, achieving zero incidence of VAP several times during 12 months, whenever VAP bundle compliance was over 90%. These results suggest that it is possible to reduce VAP rates to near zero and sustain these rates, but it requires a complex process involving multiple performance measures and interventions that must be permanently monitored.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Pipe sizes and discharge rates for enclosed ventilation... Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.437 Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment. (a) The minimum pipe size for the initial...
Kim, Eugene; Kim, Hyun Joo; Hong, Deok Man; Park, Hee-Pyoung; Bahk, Jae-Hyon
2016-09-01
It remains unclear whether we have to interrupt mechanical ventilation during infraclavicular subclavian venous catheterization. In practice, the clinicians' choice about lung deflation depends on their own discretion. The purpose of this study was to assess the influence of mechanical ventilation on the incidence of pneumothorax during infraclavicular subclavian venous catheterization. A total of 332 patients, who needed subclavian venous catheterization, were randomly assigned to 1 of the 2 groups: catheterizations were performed with the patients' lungs under mechanical ventilation (ventilation group, n = 165) or without mechanical ventilation (deflation group, n = 167). The incidences of pneumothorax and other complications such as arterial puncture, hemothorax, or catheter misplacements and the success rate of catheterization were compared. The incidences of pneumothorax were 0% (0/165) in the ventilation group and 0.6% (1/167) in the deflation group. The incidence of pneumothorax in the deflation group was 0.6% higher than that in the ventilation group and the 2-sided 90% confidence interval for the difference was (-1.29% to 3.44%). Because the lower bound for the 2-sided 90% confidence interval, -1.29%, was higher than the predefined noninferiority margin of -3%, the inferiority of the ventilation group over the deflation group was rejected at the .05 level of significance. Other complication rates and success rates of catheterization were comparable between 2 groups. The oxygen saturation dropped below 95% in 9 patients in the deflation group, while none in the ventilation group (P = .007). The success and complication rates were similar regardless of mechanical ventilation. During infraclavicular subclavian venous catheterization, interruption of mechanical ventilation does not seem to be necessary for the prevention of pneumothorax.
Minute ventilation of cyclists, car and bus passengers: an experimental study.
Zuurbier, Moniek; Hoek, Gerard; van den Hazel, Peter; Brunekreef, Bert
2009-10-27
Differences in minute ventilation between cyclists, pedestrians and other commuters influence inhaled doses of air pollution. This study estimates minute ventilation of cyclists, car and bus passengers, as part of a study on health effects of commuters' exposure to air pollutants. Thirty-four participants performed a submaximal test on a bicycle ergometer, during which heart rate and minute ventilation were measured simultaneously at increasing cycling intensity. Individual regression equations were calculated between heart rate and the natural log of minute ventilation. Heart rates were recorded during 280 two hour trips by bicycle, bus and car and were calculated into minute ventilation levels using the individual regression coefficients. Minute ventilation during bicycle rides were on average 2.1 times higher than in the car (individual range from 1.3 to 5.3) and 2.0 times higher than in the bus (individual range from 1.3 to 5.1). The ratio of minute ventilation of cycling compared to travelling by bus or car was higher in women than in men. Substantial differences in regression equations were found between individuals. The use of individual regression equations instead of average regression equations resulted in substantially better predictions of individual minute ventilations. The comparability of the gender-specific overall regression equations linking heart rate and minute ventilation with one previous American study, supports that for studies on the group level overall equations can be used. For estimating individual doses, the use of individual regression coefficients provides more precise data. Minute ventilation levels of cyclists are on average two times higher than of bus and car passengers, consistent with the ratio found in one small previous study of young adults. The study illustrates the importance of inclusion of minute ventilation data in comparing air pollution doses between different modes of transport.
Peñuelas, Oscar; Frutos-Vivar, Fernando; Fernández, Cristina; Anzueto, Antonio; Epstein, Scott K; Apezteguía, Carlos; González, Marco; Nin, Nicholas; Raymondos, Konstantinos; Tomicic, Vinko; Desmery, Pablo; Arabi, Yaseen; Pelosi, Paolo; Kuiper, Michael; Jibaja, Manuel; Matamis, Dimitros; Ferguson, Niall D; Esteban, Andrés
2011-08-15
A new classification of patients based on the duration of liberation of mechanical ventilation has been proposed. To analyze outcomes based on the new weaning classification in a cohort of mechanically ventilated patients. Secondary analysis included 2,714 patients who were weaned and underwent scheduled extubation from a cohort of 4,968 adult patients mechanically ventilated for more than 12 hours. Patients were classified according to a new weaning classification: 1,502 patients (55%) as simple weaning,1,058 patients (39%) as difficult weaning, and 154 (6%) as prolonged weaning.Variables associated with prolonged weaning(.7d)were: severity at admission (odds ratio [OR] per unit of Simplified Acute Physiology Score II, 1.01; 95% confidence interval [CI], 1.001–1.02), duration of mechanical ventilation before first attempt of weaning (OR per day, 1.10; 95% CI, 1.06–1.13), chronic pulmonary disease other than chronic obstructive pulmonary disease (OR,13.23; 95% CI, 3.44–51.05), pneumonia as the reason to start mechanical ventilation (OR, 1.82; 95% CI, 1.07–3.08), and level of positive end-expiratory pressure applied before weaning (OR per unit,1.09; 95% CI, 1.04–1.14). The prolonged weaning group had a nonsignificant trend toward a higher rate of reintubation (P ¼ 0.08),tracheostomy (P ¼ 0.15), and significantly longer length of stay and higher mortality in the intensive care unit (OR for death, 1.97;95%CI, 1.17–3.31). The adjusted probability of death remained constant until Day 7, at which point it increased to 12.1%.
Neumann, Roland P; Pillow, Jane J; Thamrin, Cindy; Larcombe, Alexander N; Hall, Graham L; Schulzke, Sven M
2015-01-01
Ventilated preterm infant lungs are vulnerable to overdistension and underinflation. The optimal ventilator-delivered tidal volume (VT) in these infants is unknown and may depend on the extent of alveolarisation at birth. We aimed to calculate respiratory dead space (VD) from the molar mass (MM) signal of an ultrasonic flowmeter (VD,MM) in very preterm infants on volume-targeted ventilation (VT target, 4-5 ml/kg) and to study the association between gestational age (GA) and VD,MM-to-VT ratio (VD,MM/VT), alveolar tidal volume (VA) and alveolar minute volume (AMV). This was a single-centre, prospective, observational, cohort study in a neonatal intensive care unit. Tidal breathing analysis was performed in ventilated very preterm infants (GA range 23-32 weeks) on day 1 of life. Valid measurements were obtained in 43/51 (87%) infants. Tidal breathing variables were analysed using multivariable linear regression. VD,MM/VT was negatively associated with GA after adjusting for birth weight Z score (p < 0.001, R(2) = 0.26). This association was primarily influenced by the appliance dead space. Despite similar VT/kg and VA/kg across all studied infants, respiratory rate and AMV/kg increased with GA. VD,app rather than anatomical VD is the major factor influencing increased VD,MM/VT at a younger GA. A volume guarantee setting of 4-5 ml/kg in the Dräger Babylog® 8000 plus ventilator may be inappropriate as a universal target across the GA range of 23-32 weeks. Differences between measured and set VT and the dependence of this difference on GA require further investigation. © 2014 S. Karger AG, Basel.
Valencia, Mauricio; Ferrer, Miquel; Farre, Ramon; Navajas, Daniel; Badia, Joan Ramon; Nicolas, Josep Maria; Torres, Antoni
2007-06-01
The aspiration of subglottic secretions colonized by bacteria pooled around the tracheal tube cuff due to inadvertent deflation (<20 cm H2O) of the cuff plays a relevant role in the pathogenesis of ventilator-associated pneumonia. We assessed the efficacy of an automatic, validated device for the continuous regulation of tracheal tube cuff pressure in preventing ventilator-associated pneumonia. Prospective randomized controlled trial. Respiratory intensive care unit and general medical intensive care unit. One hundred and forty-two mechanically ventilated patients (age, 64 +/- 17 yrs; Acute Physiology and Chronic Health Evaluation II score, 18 +/- 6) without pneumonia or aspiration at admission. Within 24 hrs of intubation, patients were randomly allocated to undergo continuous regulation of the cuff pressure with the automatic device (n = 73) or routine care of the cuff pressure (control group, n = 69). Patients remained in a semirecumbent position in bed. The primary end point variable was the incidence of ventilator-associated pneumonia. Main causes for intubation were decreased consciousness (43, 30%) and exacerbation of chronic respiratory diseases (38, 27%). Cuff pressure <20 cm H2O was more frequently observed in the control than the automatic group (45.3 vs. 0.7% determinations, p < .001). However, the rate of ventilator-associated pneumonia with clinical criteria (16, 22% vs. 20, 29%) and microbiological confirmation (11, 15% vs. 10, 15%), the distribution of early and late onset, the causative microorganisms, and intensive care unit (20, 27% vs. 16, 23%) and hospital mortality (30, 41% vs. 23, 33%) were similar for the automatic and control groups, respectively. Cuff pressure is better controlled with the automatic device. However, it did not result in additional benefits to the semirecumbent position in preventing ventilator-associated pneumonia.
Pediatric Ventilator-Associated Infections: The Ventilator-Associated INfection Study.
Willson, Douglas F; Hoot, Michelle; Khemani, Robinder; Carrol, Christopher; Kirby, Aileen; Schwarz, Adam; Gedeit, Rainer; Nett, Sholeen T; Erickson, Simon; Flori, Heidi; Hays, Spencer; Hall, Mark
2017-01-01
Suspected ventilator-associated infection is the most common reason for antibiotics in the PICU. We sought to characterize the clinical variables associated with continuing antibiotics after initial evaluation for suspected ventilator-associated infection and to determine whether clinical variables or antibiotic treatment influenced outcomes. Prospective, observational cohort study conducted in 47 PICUs in the United States, Canada, and Australia. Two hundred twenty-nine pediatric patients ventilated more than 48 hours undergoing respiratory secretion cultures were enrolled as "suspected ventilator-associated infection" in a prospective cohort study, those receiving antibiotics of less than or equal to 3 days were categorized as "evaluation only," and greater than 3 days as "treated." Demographics, diagnoses, comorbidities, culture results, and clinical data were compared between evaluation only and treated subjects and between subjects with positive versus negative cultures. PICUs in 47 hospitals in the United States, Canada, and Australia. All patients undergoing respiratory secretion cultures during the 6 study periods. None. Treated subjects differed from evaluation-only subjects only in frequency of positive cultures (79% vs 36%; p < 0.0001). Subjects with positive cultures were more likely to have chronic lung disease, tracheostomy, and shorter PICU stay, but there were no differences in ventilator days or mortality. Outcomes were similar in subjects with positive or negative cultures irrespective of antibiotic treatment. Immunocompromise and higher Pediatric Logistic Organ Dysfunction scores were the only variables associated with mortality in the overall population, but treated subjects with endotracheal tubes had significantly lower mortality. Positive respiratory cultures were the primary determinant of continued antibiotic treatment in children with suspected ventilator-associated infection. Positive cultures were not associated with worse outcomes irrespective of antibiotic treatment although the lower mortality in treated subjects with endotracheal tubes is notable. The necessity of continuing antibiotics for a positive respiratory culture in suspected ventilator-associated infection requires further study.
Does an oral care protocol reduce VAP in patients with a tracheostomy?
Conley, Patricia; McKinsey, David; Graff, Jason; Ramsey, Anthony R
2013-07-01
Several studies have demonstrated that oral care with chlorhexidine gluconate (CHG) 0.12% solution reduces the incidence of ventilator-associated pneumonia (VAP) in mechanically ventilated patients with endotracheal tubes in the ICU. Minimal evidence shows the effectiveness of any oral care protocols in preventing VAP in mechanically ventilated patients with tracheostomies in a step-down or progressive care unit (PCU). To determine the effectiveness of an oral care protocol in reducing the VAP rate in mechanically ventilated patients with tracheostomies in the PCU. A 12-month prospective study was conducted on 75 mechanically ventilated patients who had tracheostomies. The oral care protocol consisted of tooth brushing with toothpaste and applying CHG 0.12% solution every 12 hours. At the conclusion of the study, the VAP rate in the study population was compared with the National Health and Safety Network (NHSN) report for 2009 benchmark of 1.5 per 1,000 ventilator days. After the oral care protocol was implemented in the PCU, the VAP rate was 1.1 per 1,000 ventilator days over 12 months, compared with the NHSN report for 2009 of 1.5 per 1,000 ventilator days. Tooth brushing with toothpaste and applying CHG 0.12% solution may be an effective oral care protocol to reduce the VAP rate in patients in PCUs with tracheostomies who are being mechanically ventilated.
Validating computational predictions of night-time ventilation in Stanford's Y2E2 building
NASA Astrophysics Data System (ADS)
Chen, Chen; Lamberti, Giacomo; Gorle, Catherine
2017-11-01
Natural ventilation can significantly reduce building energy consumption, but robust design is a challenging task. We previously presented predictions of natural ventilation performance in Stanford's Y2E2 building using two models with different levels of fidelity, embedded in an uncertainty quantification framework to identify the dominant uncertain parameters and predict quantified confidence intervals. The results showed a slightly high cooling rate for the volume-averaged temperature, and the initial thermal mass temperature and window discharge coefficients were found to have an important influence on the results. To further investigate the potential role of these parameters on the observed discrepancies, the current study is performing additional measurements in the Y2E2 building. Wall temperatures are recorded throughout the nightflush using thermocouples; flow rates through windows are measured using hotwires; and spatial variability in the air temperature is explored. The measured wall temperatures are found the be within the range of our model assumptions, and the measured velocities agree reasonably well with our CFD predications. Considerable local variations in the indoor air temperature have been recorded, largely explaining the discrepancies in our earlier validation study. Future work will therefore focus on a local validation of the CFD results with the measurements. Center for Integrated Facility Engineering (CIFE).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chan, Wanyu R.; Sidheswaran, Meera; Cohn, Sebastian
2014-02-01
This field study measured ventilation rates and indoor air quality parameters in 21 visits to retail stores in California. The data was collected to guide the development of new, science-based commercial building ventilation rate standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. Data collection occurred between September 2011 and March 2013. Three types of stores participated in this study: grocery stores, furniture/hardware stores, and apparel stores. Ventilation rates and indoor air contaminant concentrations were measured on a weekday, typically between 9 am and 6 pm. Ventilation rates measured using a tracer gasmore » decay method exceeded the minimum requirement of California’s Title 24 Standard in all but one store. Even though there was adequate ventilation according to Title 24, concentrations of formaldehyde, acetaldehyde, and acrolein exceeded the most stringent chronic health guidelines. Other indoor air contaminants measured included carbon dioxide (CO{sub 2}), carbon monoxide (CO), ozone (O{sub 3}), and particulate matter (PM). Concentrations of CO{sub 2} were kept low by adequate ventilation, and were assumed low also because the sampling occurred on a weekday when retail stores were less busy. CO concentrations were also low. The indoor-outdoor ratios of O{sub 3} showed that the first-order loss rate may vary by store trade types and also by ventilation mode (mechanical versus natural). Analysis of fine and ultrafine PM measurements showed that a substantial portion of the particle mass in grocery stores with cooking-related emissions was in particles less than 0.3 μm. Stores without cooking as an indoor source had PM size distributions that were more similar indoors and outdoors. The whole-building emission rates of volatile organic compounds (VOCs) and PM were estimated from the measured ventilation rates and indoor and outdoor contaminant concentrations. Mass balance models were then used to determine the ventilation rates, filtration strategies, or source reductions needed to maintain indoor contaminant concentrations below reference levels. Several scenarios of potential concern were considered: (i) formaldehyde levels in furniture/hardware stores, (ii) contaminants associated with cooking (e.g., PM, acrolein, and acetaldehyde) in grocery stores, and (iii) outdoor contaminants (e.g., PM and O{sub 3}) impacting stores that use natural ventilation. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California’s stringent formaldehyde reference level. Given the high costs of providing ventilation but only modest chronic health benefit is expected, effective source control is an attractive alternative, as demonstrated by some retail stores in this study. Predictions showed that grocery stores need MERV 13 air filters, instead of MERV 8 filters that are more commonly used, to maintain indoor PM at levels that meet the chronic health standards for PM. Exposure to acrolein is a potential health concern in grocery stores, and should be addressed by increasing the use of kitchen range hoods or improving their contaminant removal efficiency. In stores that rely on natural ventilation, indoor PM can be a health concern if the stores are located in areas with high outdoor PM. This concern may be addressed by switching to mechanical ventilation when the outdoor air quality is poor, while continuing natural ventilation when outdoor air quality is good.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krarti, M.; Ayari, A.M.
1999-07-01
This paper provides an overview of the current standards and regulations regarding the ventilation in enclosed parking facilities in the US and other countries. First, the paper discusses the emission rates of motor vehicle pollutants and their health effects. In particular, typical emission rates for different vehicle and fuel types are presented to highlight the effect of various parameters on the ventilation rate requirements for parking garages. In addition, the paper provides a brief description of some of the common ventilation problems reported in the literature for enclosed parking garages.
Models for nearly every occasion: Part I - One box models.
Hewett, Paul; Ganser, Gary H
2017-01-01
The standard "well mixed room," "one box" model cannot be used to predict occupational exposures whenever the scenario involves the use of local controls. New "constant emission" one box models are proposed that permit either local exhaust or local exhaust with filtered return, coupled with general room ventilation or the recirculation of a portion of the general room exhaust. New "two box" models are presented in Part II of this series. Both steady state and transient models were developed. The steady state equation for each model, including the standard one box steady state model, is augmented with an additional factor reflecting the fraction of time the substance was generated during each task. This addition allows the easy calculation of the average exposure for cyclic and irregular emission patterns, provided the starting and ending concentrations are zero or near zero, or the cumulative time across all tasks is long (e.g., several tasks to a full shift). The new models introduce additional variables, such as the efficiency of the local exhaust to immediately capture freshly generated contaminant and the filtration efficiency whenever filtered exhaust is returned to the workspace. Many of the model variables are knowable (e.g., room volume and ventilation rate). A structured procedure for calibrating a model to a work scenario is introduced that can be applied to both continuous and cyclic processes. The "calibration" procedure generates estimates of the generation rate and all of remaining unknown model variables.
Nurse working conditions and patient safety outcomes.
Stone, Patricia W; Mooney-Kane, Cathy; Larson, Elaine L; Horan, Teresa; Glance, Laurent G; Zwanziger, Jack; Dick, Andrew W
2007-06-01
System approaches, such as improving working conditions, have been advocated to improve patient safety. However, the independent effect of many working condition variables on patient outcomes is unknown. To examine effects of a comprehensive set of working conditions on elderly patient safety outcomes in intensive care units. Observational study, with patient outcome data collected using the National Nosocomial Infection Surveillance system protocols and Medicare files. Several measures of health status and fixed setting characteristics were used to capture distinct dimensions of patient severity of illness and risk for disease. Working condition variables included organizational climate measured by nurse survey; objective measures of staffing, overtime, and wages (derived from payroll data); and hospital profitability and magnet accreditation. The sample comprised 15,846 patients in 51 adult intensive care units in 31 hospitals depending on the outcome analyzed; 1095 nurses were surveyed. Central line associated bloodstream infections (CLBSI), ventilator-associated pneumonia, catheter-associated urinary tract infections, 30-day mortality, and decubiti. Units with higher staffing had lower incidence of CLBSI, ventilator-associated pneumonia, 30-day mortality, and decubiti (P
Energy and Cost Associated with Ventilating Office Buildings in a Tropical Climate
Rim, Donghyun; Schiavon, Stefano; Nazaroff, William W.
2015-01-01
Providing sufficient amounts of outdoor air to occupants is a critical building function for supporting occupant health, well-being and productivity. In tropical climates, high ventilation rates require substantial amounts of energy to cool and dehumidify supply air. This study evaluates the energy consumption and associated cost for thermally conditioning outdoor air provided for building ventilation in tropical climates, considering Singapore as an example locale. We investigated the influence on energy consumption and cost of the following factors: outdoor air temperature and humidity, ventilation rate (L/s per person), indoor air temperature and humidity, air conditioning system coefficient of performance (COP), and cost of electricity. Results show that dehumidification of outdoor air accounts for more than 80% of the energy needed for building ventilation in Singapore’s tropical climate. Improved system performance and/or a small increase in the indoor temperature set point would permit relatively large ventilation rates (such as 25 L/s per person) at modest or no cost increment. Overall, even in a thermally demanding tropical climate, the energy cost associated with increasing ventilation rate up to 25 L/s per person is less than 1% of the wages of an office worker in an advanced economy like Singapore’s. This result implies that the benefits of increasing outdoor air ventilation rate up to 25 L/s per person — which is suggested to provide for productivity increases, lower sick building syndrome symptom prevalence, and reduced sick leave — can be much larger than the incremental cost of ventilation. PMID:25822504
Use of a single ventilator to support 4 patients: laboratory evaluation of a limited concept.
Branson, Richard D; Blakeman, Thomas C; Robinson, Bryce Rh; Johannigman, Jay A
2012-03-01
A mass-casualty respiratory failure event where patients exceed available ventilators has spurred several proposed solutions. One proposal is use of a single ventilator to support 4 patients. A ventilator was modified to allow attachment of 4 circuits. Each circuit was connected to one chamber of 2 dual-chambered, test lungs. The ventilator was set at a tidal volume (V(T)) of 2.0 L, respiratory frequency of 10 breaths/min, and PEEP of 5 cm H(2)O. Tests were repeated with pressure targeted breaths at 15 cm H(2)O. Airway pressure, volume, and flow were measured at each chamber. The test lungs were set to simulate 4 patients using combinations of resistance (R) and compliance (C). These included equivalent C and R, constant R and variable C, constant C and variable R, and variable C and variable R. When R and C were equivalent the V(T) distributed to each chamber of the test lung was similar during both volume (range 428-442 mL) and pressure (range 528-544 mL) breaths. Changing C while R was constant resulted in large variations in delivered V(T) (volume range 257-621 mL, pressure range 320-762 mL). Changing R while C was constant resulted in a smaller variation in V(T) (volume range 418-460 mL, pressure range 502-554 mL) compared to only C changes. When R and C were both varied, the range of delivered V(T) in both volume (336-517 mL) and pressure (417-676 mL) breaths was greater, compared to only R changes. Using a single ventilator to support 4 patients is an attractive concept; however, the V(T) cannot be controlled for each subject and V(T) disparity is proportional to the variability in compliance. Along with other practical limitations, these findings cannot support the use of this concept for mass-casualty respiratory failure.
Na, Ji Ung; Han, Sang Kuk; Choi, Pil Cho; Shin, Dong Hyuk
2017-01-01
Metronome guidance is a feasible and effective feedback technique to improve the quality of cardiopulmonary resuscitation (CPR). The rate of the metronome should be set between 100 to 120 ticks/minute and the speed of ventilation may have crucial effect on the quality of ventilation. We compared three different metronome rates (100, 110, 120 ticks/minute) to investigate its effect on the quality of ventilation during metronome-guided 30:2 CPR. This is a prospective, randomized, crossover observational study using a RespiTrainer○ r . To simulate 30 chest compressions, one investigator counted from 1 to 30 in cadence with the metronome rate (1 count for every 1 tick), and the participant performed 2 consecutive ventilations immediately following the counting of 30. Thirty physicians performed 5 sets of 2 consecutive (total 10) bag-mask ventilations for each metronome rate. Participants were instructed to squeeze the bag over 2 ticks (1.0 to 1.2 seconds depending on the rate of metronome) and deflate the bag over 2 ticks. The sequence of three different metronome rates was randomized. Mean tidal volume significantly decreased as the metronome rate was increased from 110 ticks/minute to 120 ticks/minute (343±84 mL vs. 294±90 mL, P =0.004). Peak airway pressure significantly increased as metronome rate increased from 100 ticks/minute to 110 ticks/minute (18.7 vs. 21.6 mmHg, P =0.006). In metronome-guided 30:2 CPR, a higher metronome rate may adversely affect the quality of bag-mask ventilations. In cases of cardiac arrest where adequate ventilation support is necessary, 100 ticks/minute may be better than 110 or 120 ticks/minute to deliver adequate tidal volume during audio tone guided 30:2 CPR.
Na, Ji Ung; Han, Sang Kuk; Choi, Pil Cho; Shin, Dong Hyuk
2017-01-01
BACKGROUND: Metronome guidance is a feasible and effective feedback technique to improve the quality of cardiopulmonary resuscitation (CPR). The rate of the metronome should be set between 100 to 120 ticks/minute and the speed of ventilation may have crucial effect on the quality of ventilation. We compared three different metronome rates (100, 110, 120 ticks/minute) to investigate its effect on the quality of ventilation during metronome-guided 30:2 CPR. METHODS: This is a prospective, randomized, crossover observational study using a RespiTrainer○r. To simulate 30 chest compressions, one investigator counted from 1 to 30 in cadence with the metronome rate (1 count for every 1 tick), and the participant performed 2 consecutive ventilations immediately following the counting of 30. Thirty physicians performed 5 sets of 2 consecutive (total 10) bag-mask ventilations for each metronome rate. Participants were instructed to squeeze the bag over 2 ticks (1.0 to 1.2 seconds depending on the rate of metronome) and deflate the bag over 2 ticks. The sequence of three different metronome rates was randomized. RESULTS: Mean tidal volume significantly decreased as the metronome rate was increased from 110 ticks/minute to 120 ticks/minute (343±84 mL vs. 294±90 mL, P=0.004). Peak airway pressure significantly increased as metronome rate increased from 100 ticks/minute to 110 ticks/minute (18.7 vs. 21.6 mmHg, P=0.006). CONCLUSION: In metronome-guided 30:2 CPR, a higher metronome rate may adversely affect the quality of bag-mask ventilations. In cases of cardiac arrest where adequate ventilation support is necessary, 100 ticks/minute may be better than 110 or 120 ticks/minute to deliver adequate tidal volume during audio tone guided 30:2 CPR. PMID:28458759
Adaptive support ventilation: State of the art review
Fernández, Jaime; Miguelena, Dayra; Mulett, Hernando; Godoy, Javier; Martinón-Torres, Federico
2013-01-01
Mechanical ventilation is one of the most commonly applied interventions in intensive care units. Despite its life-saving role, it can be a risky procedure for the patient if not applied appropriately. To decrease risks, new ventilator modes continue to be developed in an attempt to improve patient outcomes. Advances in ventilator modes include closed-loop systems that facilitate ventilator manipulation of variables based on measured respiratory parameters. Adaptive support ventilation (ASV) is a positive pressure mode of mechanical ventilation that is closed-loop controlled, and automatically adjust based on the patient's requirements. In order to deliver safe and appropriate patient care, clinicians need to achieve a thorough understanding of this mode, including its effects on underlying respiratory mechanics. This article will discuss ASV while emphasizing appropriate ventilator settings, their advantages and disadvantages, their particular effects on oxygenation and ventilation, and the monitoring priorities for clinicians. PMID:23833471
High tidal volume ventilation induces NOS2 and impairs cAMP- dependent air space fluid clearance.
Frank, James A; Pittet, Jean-Francois; Lee, Hyon; Godzich, Micaela; Matthay, Michael A
2003-05-01
Tidal volume reduction during mechanical ventilation reduces mortality in patients with acute lung injury and the acute respiratory distress syndrome. To determine the mechanisms underlying the protective effect of low tidal volume ventilation, we studied the time course and reversibility of ventilator-induced changes in permeability and distal air space edema fluid clearance in a rat model of ventilator-induced lung injury. Anesthetized rats were ventilated with a high tidal volume (30 ml/kg) or with a high tidal volume followed by ventilation with a low tidal volume of 6 ml/kg. Endothelial and epithelial protein permeability were significantly increased after high tidal volume ventilation but returned to baseline levels when tidal volume was reduced. The basal distal air space fluid clearance (AFC) rate decreased by 43% (P < 0.05) after 1 h of high tidal volume but returned to the preventilation rate 2 h after tidal volume was reduced. Not all of the effects of high tidal volume ventilation were reversible. The cAMP-dependent AFC rate after 1 h of 30 ml/kg ventilation was significantly reduced and was not restored when tidal volume was reduced. High tidal volume ventilation also increased lung inducible nitric oxide synthase (NOS2) expression and air space total nitrite at 3 h. Inhibition of NOS2 activity preserved cAMP-dependent AFC. Because air space edema fluid inactivates surfactant and reduces ventilated lung volume, the reduction of cAMP-dependent AFC by reactive nitrogen species may be an important mechanism of clinical ventilator-associated lung injury.
Significant Improvements in Pyranometer Nighttime Offsets Using High-Flow DC Ventilation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michalsky, Joseph J.; Kutchenreiter, Mark; Long, Charles N.
Ventilators are used to keep the domes of pyranometers clean and dry, but they affect the nighttime offset as well. This paper examines different ventilation strategies. For the several commercial single-black-detector pyranometers with ventilators examined here, high flow rate (50 CFM and higher), 12 VDC fans lower the offsets, lower the scatter, and improve the predictability of the offsets during the night compared with lower flow rate 35 CFM, 120 VAC fans operated in the same ventilator housings. Black-and-white pyranometers sometimes show improvement with DC ventilation, but in some cases DC ventilation makes the offsets slightly worse. Since the offsetsmore » for these black-and-white pyranometers are always small, usually no more than 1 Wm -2, whether AC or DC ventilated, changing their ventilation to higher CFM DC ventilation is not imperative. Future work should include all major manufacturers of pyranometers and unventilated, as well as, ventilated pyranometers. Lastly, an important outcome of future research will be to clarify under what circumstances nighttime data can be used to predict daytime offsets.« less
Significant Improvements in Pyranometer Nighttime Offsets Using High-Flow DC Ventilation
Michalsky, Joseph J.; Kutchenreiter, Mark; Long, Charles N.
2017-06-20
Ventilators are used to keep the domes of pyranometers clean and dry, but they affect the nighttime offset as well. This paper examines different ventilation strategies. For the several commercial single-black-detector pyranometers with ventilators examined here, high flow rate (50 CFM and higher), 12 VDC fans lower the offsets, lower the scatter, and improve the predictability of the offsets during the night compared with lower flow rate 35 CFM, 120 VAC fans operated in the same ventilator housings. Black-and-white pyranometers sometimes show improvement with DC ventilation, but in some cases DC ventilation makes the offsets slightly worse. Since the offsetsmore » for these black-and-white pyranometers are always small, usually no more than 1 Wm -2, whether AC or DC ventilated, changing their ventilation to higher CFM DC ventilation is not imperative. Future work should include all major manufacturers of pyranometers and unventilated, as well as, ventilated pyranometers. Lastly, an important outcome of future research will be to clarify under what circumstances nighttime data can be used to predict daytime offsets.« less
Alsadat, Reem; Al-Bardan, Hussam; Mazloum, Mona N; Shamah, Asem A; Eltayeb, Mohamed F E; Marie, Ali; Dakkak, Abdulrahman; Naes, Ola; Esber, Faten; Betelmal, Ibrahim; Kherallah, Mazen
2012-10-01
Implementation of ventilator associated pneumonia (VAP) bundle as a performance improvement project in the critical care units for all mechanically ventilated patients aiming to decrease the VAP rates. VAP bundle was implemented in 4 teaching hospitals after educational sessions and compliance rates along with VAP rates were monitored using statistical process control charts. VAP bundle compliance rates were steadily increasing from 33 to 80% in hospital 1, from 33 to 86% in hospital 2 and from 83 to 100% in hospital 3 during the study period. The VAP bundle was not applied in hospital 4 therefore no data was available. A target level of 95% was reached only in hospital 3. This correlated with a decrease in VAP rates from 30 to 6.4 per 1000 ventilator days in hospital 1, from 12 to 4.9 per 1000 ventilator days in hospital 3, whereas VAP rate failed to decrease in hospital 2 (despite better compliance) and it remained high around 33 per 1000 ventilator days in hospital 4 where VAP bundle was not implemented. VAP bundle has performed differently in different hospitals in our study. Prevention of VAP requires a multidimensional strategy that includes strict infection control interventions, VAP bundle implementation, process and outcome surveillance and education.
Metronome improves compression and ventilation rates during CPR on a manikin in a randomized trial.
Kern, Karl B; Stickney, Ronald E; Gallison, Leanne; Smith, Robert E
2010-02-01
We hypothesized that a unique tock and voice metronome could prevent both suboptimal chest compression rates and hyperventilation. A prospective, randomized, parallel design study involving 34 pairs of paid firefighter/emergency medical technicians (EMTs) performing two-rescuer CPR using a Laerdal SkillReporter Resusci Anne manikin with and without metronome guidance was performed. Each CPR session consisted of 2 min of 30:2 CPR with an unsecured airway, then 4 min of CPR with a secured airway (continuous compressions at 100 min(-1) with 8-10 ventilations/min), repeated after the rescuers switched roles. The metronome provided "tock" prompts for compressions, transition prompts between compressions and ventilations, and a spoken "ventilate" prompt. During CPR with a bag/valve/mask the target compression rate of 90-110 min(-1) was achieved in 5/34 CPR sessions (15%) for the control group and 34/34 sessions (100%) for the metronome group (p<0.001). An excessive ventilation rate was not observed in either the metronome or control group during CPR with a bag/valve/mask. During CPR with a bag/endotracheal tube, the target of both a compression rate of 90-110 min(-1) and a ventilation rate of 8-11 min(-1) was achieved in 3/34 CPR sessions (9%) for the control group and 33/34 sessions (97%) for the metronome group (p<0.001). Metronome use with the secured airway scenario significantly decreased the incidence of over-ventilation (11/34 EMT pairs vs. 0/34 EMT pairs; p<0.001). A unique combination tock and voice prompting metronome was effective at directing correct chest compression and ventilation rates both before and after intubation. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
Mechanisms and sources of radon entry in buildings constructed with modern technologies.
Zhukovsky, M V; Vasilyev, A V
2014-07-01
To investigate the influence of modern building construction technologies on the accumulation of radon indoor, 20 rooms in buildings constructed using mostly monolithic concrete or aerated concrete blocks have been studied. Dominance of the diffusion mechanism of radon entry in buildings constructed with modern technologies has been established. As a result of computer simulations it was found that the main contribution to the variability of radon concentration was made by changes in the ventilation rate. At a low ventilation rate (<0.2 h(-1)) radon concentration above 200 Bq m(-3) can be observed for residential buildings. There is a need for the regulation of the radium-specific activity in building materials. According to the estimates of this study, the content of 226Ra in building materials should not exceed the value of 100 Bq kg(-1). © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Effect Of Ventilation On Chronic Health Risks In Schools And Offices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parthasarathy, Srinandini; Fisk, William J.; McKone, Thomas E.
This study provides a risk assessment for chronic health risks from inhalation exposure to indoor air pollutants in offices and schools with a focus how ventilation impacts exposures to, and risks from, volatile organic compounds (VOCs) and particulate matter (PM2.5). We estimate how much health risks could change with varying ventilation rates under two scenarios: (i) halving the measured ventilation rates and (ii) doubling the measured ventilation rates. For the hazard characterization we draw upon prior papers that identified pollutants potentially affecting health with indoor air concentrations responsive to changes in ventilation rates. For exposure assessment we determine representative concentrationsmore » of pollutants using data available in current literature and model changes in exposures with changes in ventilation rates. As a metric of disease burden, we use disability adjusted life years (DALYs) to address both cancer and non-cancer effects. We also compare exposures to guidelines published by regulatory agencies to assess chronic health risks. Chronic health risks are driven primarily by particulate matter exposure, with an estimated baseline disease burden of 150 DALYs per 100,000 people in offices and 140 DALYs per 100,000 people in schools. Study results show that PM2.5-related DALYs are not very sensitive to changes in ventilation rates. Filtration is more effective at controlling PM2.5 concentrations and health effects. Non-cancer health effects contribute only a small fraction of the overall chronic health burden of populations in offices and schools (<1 DALY per 100,000 people). Cancer health effects dominate the disease burden in schools (3 DALYs per 100,000) and offices (5 DALYs per 100,000), with formaldehyde being the primary risk driver. In spite of large uncertainties in toxicological data and dose-response modeling, our results support the finding that ventilation rate changes do not have significant impacts on estimated chronic disease burdens. Median estimates of DALYs are approximately doubled when the ventilation rates are halved and there is little reduction in health risks associated with doubling ventilation rates, but the very low baseline disease burden from the indoor exposures we considered makes this unremarkable. In exploring the full range of exposure concentrations, to find the fraction exceeding the Office of Environmental Health and Hazard Assessment’s (OEHHAs) chronic reference exposure levels (cRELs) and United States Environmental Protection Agency’s (USEPA) chronic reference dose (RfD) we found only minor shifts in exposure safety margins when ventilation was doubled or halved. We combined our exposure estimates with cancer potency factors published by OEHHA and USEPA to determine that the annual excess cancer risk per capita are below 1 in a million under all ventilation rate scenarios for individual pollutants. The results indicate that chronic health risks (cancer and non-cancer) associated with VOC and PM2.5 exposure in offices and schools are low and thus the chronic disease burden or health benefits of ventilation changes are likely to be well below both the level of detection by health surveillance studies and the level of regulatory thresholds.« less
Summary of human responses to ventilation.
Seppänen, O A; Fisk, W J
2004-01-01
It is known that ventilation is necessary to remove indoor-generated pollutants from indoor air or dilute their concentration to acceptable levels. But as the limit values of all pollutants are not known the exact determination of required ventilation rates based on pollutant concentrations is seldom possible. The selection of ventilation rates has to be based also on epidemiological research, laboratory and field experiments and experience. The existing literature indicates that ventilation has a significant impact on several important human outcomes including: (1) communicable respiratory illnesses; (2) sick building syndrome symptoms; (3) task performance and productivity, and (4) perceived air quality (PAQ) among occupants or sensory panels (5) respiratory allergies and asthma. In many studies, prevalence of sick building syndrome symptoms has also been associated with characteristics of HVAC-systems. Often the prevalence of SBS symptoms is higher in air-conditioned buildings than in naturally ventilated buildings. The evidence suggests that better hygiene, commissioning, operation and maintenance of air handling systems may be particularly important for reducing the negative effects of HVAC systems. Ventilation may also have harmful effects on indoor air quality and climate if not properly designed, installed, maintained and operated. Ventilation may bring indoors harmful substances or deteriorate indoor environment. Ventilation interacts also with the building envelope and may deteriorate the structures of the building. Ventilation changes the pressure differences across the structures of building and may cause or prevent infiltration of pollutants from structures or adjacent spaces. Ventilation is also in many cases used to control the thermal environment or humidity in buildings. The paper summarises the current knowledge on positive and negative effects of ventilation on health and other human responses. The focus is on office-type working environment and residential buildings. The review shows that ventilation has various positive impacts on health and productivity of building occupants. Ventilation reduces the prevalence of airborne infectious diseases and thus the number of sick leave days. In office environment a ventilation rate up to 20-25 L/s per person seem to decrease the prevalence of SBS-symptoms. Air conditioning systems may increase the prevalence of SBS-symptoms relative to natural ventilation if not clean. In residential buildings the air change rate in cold climates should not be below app. 0.5 ach. Ventilation systems may cause pressure differences over the building envelope and bring harmful pollutants indoors.
Jiamjarasrangsi, W; Bualert, S; Chongthaleong, A; Chaindamporn, A; Udomsantisuk, N; Euasamarnjit, W
2009-04-01
Forty-two community and general hospitals in central Thailand. To examine the adequacy of indoor ventilation for nosocomial tuberculosis (TB) prevention in public hospitals in central Thailand. A cross-sectional survey was conducted among 323 patient care and ancillary areas in the target hospitals. Data on indoor ventilation rate were collected by the tracer gas method and reported as air changes per hour (ACH). The adequacy of the measured ventilation rates were then determined by comparison with the international recommended standard values. Indoor ventilation rates were inadequate in almost half of the studied areas (144/323, 44.6%). The inadequacy was particularly serious in the emergency rooms (ERs) and radiological areas, where 73.8% (31/42 each) of the rooms had ACH below the recommended standards. Detailed analysis showed that most of the rooms with natural ventilation had air exchange rates that exceeded the recommended standards, while the opposite was the case for rooms with air-conditioning, particularly the window or wall-mount type. Indoor ventilation in high-risk nosocomial TB areas in public hospitals in Thailand was inadequate due to the installation of air-conditioning systems in modern buildings.
Campbell, Hamish A; Leite, Cleo A C; Wang, Tobias; Skals, Marianne; Abe, Augusto S; Egginton, Stuart; Rantin, F Tadeu; Bishop, Charles M; Taylor, Edwin W
2006-07-01
Autonomic control of heart rate variability and the central location of vagal preganglionic neurones (VPN) were examined in the rattlesnake (Crotalus durissus terrificus), in order to determine whether respiratory sinus arrhythmia (RSA) occurred in a similar manner to that described for mammals. Resting ECG signals were recorded in undisturbed snakes using miniature datalogging devices, and the presence of oscillations in heart rate (fh) was assessed by power spectral analysis (PSA). This mathematical technique provides a graphical output that enables the estimation of cardiac autonomic control by measuring periodic changes in the heart beat interval. At fh above 19 min(-1) spectra were mainly characterised by low frequency components, reflecting mainly adrenergic tonus on the heart. By contrast, at fh below 19 min(-1) spectra typically contained high frequency components, demonstrated to be cholinergic in origin. Snakes with a fh >19 min(-1) may therefore have insufficient cholinergic tonus and/or too high an adrenergic tonus acting upon the heart for respiratory sinus arrhythmia (RSA) to develop. A parallel study monitored fh simultaneously with the intraperitoneal pressures associated with lung inflation. Snakes with a fh<19 min(-1) exhibited a high frequency (HF) peak in the power spectrum, which correlated with ventilation rate (fv). Adrenergic blockade by propranolol infusion increased the variability of the ventilation cycle, and the oscillatory component of the fh spectrum broadened accordingly. Infusion of atropine to effect cholinergic blockade abolished this HF component, confirming a role for vagal control of the heart in matching fh and fv in the rattlesnake. A neuroanatomical study of the brainstem revealed two locations for vagal preganglionic neurones (VPN). This is consistent with the suggestion that generation of ventilatory components in the heart rate variability (HRV) signal are dependent on spatially distinct loci for cardiac VPN. Therefore, this study has demonstrated the presence of RSA in the HRV signal and a dual location for VPN in the rattlesnake. We suggest there to be a causal relationship between these two observations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kipritidis, John, E-mail: john.kipritidis@sydney.edu.au; Keall, Paul J.; Hugo, Geoffrey
Purpose: Adaptive ventilation guided radiation therapy could minimize the irradiation of healthy lung based on repeat lung ventilation imaging (VI) during treatment. However the efficacy of adaptive ventilation guidance requires that interfraction (e.g., week-to-week), ventilation changes are not washed out by intrafraction (e.g., pre- and postfraction) changes, for example, due to patient breathing variability. The authors hypothesize that patients undergoing lung cancer radiation therapy exhibit larger interfraction ventilation changes compared to intrafraction function changes. To test this, the authors perform the first comparison of interfraction and intrafraction lung VI pairs using four-dimensional cone beam CT ventilation imaging (4D-CBCT VI), amore » novel technique for functional lung imaging. Methods: The authors analyzed a total of 215 4D-CBCT scans acquired for 19 locally advanced non-small cell lung cancer (LA-NSCLC) patients over 4–6 weeks of radiation therapy. This set of 215 scans was sorted into 56 interfraction pairs (including first day scans and each of treatment weeks 2, 4, and 6) and 78 intrafraction pairs (including pre/postfraction scans on the same-day), with some scans appearing in both sets. VIs were obtained from the Jacobian determinant of the transform between the 4D-CBCT end-exhale and end-inhale images after deformable image registration. All VIs were deformably registered to their corresponding planning CT and normalized to account for differences in breathing effort, thus facilitating image comparison in terms of (i) voxelwise Spearman correlations, (ii) mean image differences, and (iii) gamma pass rates for all interfraction and intrafraction VI pairs. For the side of the lung ipsilateral to the tumor, we applied two-sided t-tests to determine whether interfraction VI pairs were more different than intrafraction VI pairs. Results: The (mean ± standard deviation) Spearman correlation for interfraction VI pairs was r{sup -}{sub Inter}=0.52±0.25, which was significantly lower than for intrafraction pairs (r{sup -}{sub Intra}=0.67±0.20, p = 0.0002). Conversely, mean absolute ventilation differences were larger for interfraction pairs than for intrafraction pairs, with |ΔV{sup -}{sub Inter}|=0.42±0.65 and |ΔV{sup -}{sub Intra}|=0.32±0.53, respectively (p < 10{sup −15}). Applying a gamma analysis with ventilation/distance tolerance of 25%/10 mm, we observed mean pass rate of (69% ± 20%) for interfraction VIs, which was significantly lower compared to intrafraction pairs (80% ± 15%, with p ∼ 0.0003). Compared to the first day scans, all patients experienced at least one subsequent change in median ipsilateral ventilation ≥10%. Patients experienced both positive and negative ventilation changes throughout treatment, with the maximum change occurring at different weeks for different patients. Conclusions: The authors’ data support the hypothesis that interfraction ventilation changes are larger than intrafraction ventilation changes for LA-NSCLC patients over a course of conventional lung cancer radiation therapy. Longitudinal ventilation changes are observed to be highly patient-dependent, supporting a possible role for adaptive ventilation guidance based on repeat 4D-CBCT VIs. We anticipate that future improvement of 4D-CBCT image reconstruction algorithms will improve the capability of 4D-CBCT VI to resolve interfraction ventilation changes.« less
Kipritidis, John; Hugo, Geoffrey; Weiss, Elisabeth; Williamson, Jeffrey; Keall, Paul J
2015-03-01
Adaptive ventilation guided radiation therapy could minimize the irradiation of healthy lung based on repeat lung ventilation imaging (VI) during treatment. However the efficacy of adaptive ventilation guidance requires that interfraction (e.g., week-to-week), ventilation changes are not washed out by intrafraction (e.g., pre- and postfraction) changes, for example, due to patient breathing variability. The authors hypothesize that patients undergoing lung cancer radiation therapy exhibit larger interfraction ventilation changes compared to intrafraction function changes. To test this, the authors perform the first comparison of interfraction and intrafraction lung VI pairs using four-dimensional cone beam CT ventilation imaging (4D-CBCT VI), a novel technique for functional lung imaging. The authors analyzed a total of 215 4D-CBCT scans acquired for 19 locally advanced non-small cell lung cancer (LA-NSCLC) patients over 4-6 weeks of radiation therapy. This set of 215 scans was sorted into 56 interfraction pairs (including first day scans and each of treatment weeks 2, 4, and 6) and 78 intrafraction pairs (including pre/postfraction scans on the same-day), with some scans appearing in both sets. VIs were obtained from the Jacobian determinant of the transform between the 4D-CBCT end-exhale and end-inhale images after deformable image registration. All VIs were deformably registered to their corresponding planning CT and normalized to account for differences in breathing effort, thus facilitating image comparison in terms of (i) voxelwise Spearman correlations, (ii) mean image differences, and (iii) gamma pass rates for all interfraction and intrafraction VI pairs. For the side of the lung ipsilateral to the tumor, we applied two-sided t-tests to determine whether interfraction VI pairs were more different than intrafraction VI pairs. The (mean ± standard deviation) Spearman correlation for interfraction VI pairs was r̄(Inter)=0.52±0.25, which was significantly lower than for intrafraction pairs (r̄(Intra)=0.67±0.20, p = 0.0002). Conversely, mean absolute ventilation differences were larger for interfraction pairs than for intrafraction pairs, with |ΔV̄(Inter)|=0.42±0.65 and |ΔV̄(Intra)|=0.32±0.53, respectively (p < 10(-15)). Applying a gamma analysis with ventilation/distance tolerance of 25%/10 mm, we observed mean pass rate of (69% ± 20%) for interfraction VIs, which was significantly lower compared to intrafraction pairs (80% ± 15%, with p ∼ 0.0003). Compared to the first day scans, all patients experienced at least one subsequent change in median ipsilateral ventilation ≥10%. Patients experienced both positive and negative ventilation changes throughout treatment, with the maximum change occurring at different weeks for different patients. The authors' data support the hypothesis that interfraction ventilation changes are larger than intrafraction ventilation changes for LA-NSCLC patients over a course of conventional lung cancer radiation therapy. Longitudinal ventilation changes are observed to be highly patient-dependent, supporting a possible role for adaptive ventilation guidance based on repeat 4D-CBCT VIs. We anticipate that future improvement of 4D-CBCT image reconstruction algorithms will improve the capability of 4D-CBCT VI to resolve interfraction ventilation changes.
Determining the ventilation and aerosol deposition rates from routine indoor-air measurements.
Halios, Christos H; Helmis, Costas G; Deligianni, Katerina; Vratolis, Sterios; Eleftheriadis, Konstantinos
2014-01-01
Measurement of air exchange rate provides critical information in energy and indoor-air quality studies. Continuous measurement of ventilation rates is a rather costly exercise and requires specific instrumentation. In this work, an alternative methodology is proposed and tested, where the air exchange rate is calculated by utilizing indoor and outdoor routine measurements of a common pollutant such as SO2, whereas the uncertainties induced in the calculations are analytically determined. The application of this methodology is demonstrated, for three residential microenvironments in Athens, Greece, and the results are also compared against ventilation rates calculated from differential pressure measurements. The calculated time resolved ventilation rates were applied to the mass balance equation to estimate the particle loss rate which was found to agree with literature values at an average of 0.50 h(-1). The proposed method was further evaluated by applying a mass balance numerical model for the calculation of the indoor aerosol number concentrations, using the previously calculated ventilation rate, the outdoor measured number concentrations and the particle loss rates as input values. The model results for the indoors' concentrations were found to be compared well with the experimentally measured values.
A Prognostic Model for One-year Mortality in Patients Requiring Prolonged Mechanical Ventilation
Carson, Shannon S.; Garrett, Joanne; Hanson, Laura C.; Lanier, Joyce; Govert, Joe; Brake, Mary C.; Landucci, Dante L.; Cox, Christopher E.; Carey, Timothy S.
2009-01-01
Objective A measure that identifies patients who are at high risk of mortality after prolonged ventilation will help physicians communicate prognosis to patients or surrogate decision-makers. Our objective was to develop and validate a prognostic model for 1-year mortality in patients ventilated for 21 days or more. Design Prospective cohort study. Setting University-based tertiary care hospital Patients 300 consecutive medical, surgical, and trauma patients requiring mechanical ventilation for at least 21 days were prospectively enrolled. Measurements and Main Results Predictive variables were measured on day 21 of ventilation for the first 200 patients and entered into logistic regression models with 1-year and 3-month mortality as outcomes. Final models were validated using data from 100 subsequent patients. One-year mortality was 51% in the development set and 58% in the validation set. Independent predictors of mortality included requirement for vasopressors, hemodialysis, platelet count ≤150 ×109/L, and age ≥50. Areas under the ROC curve for the development model and validation model were 0.82 (se 0.03) and 0.82 (se 0.05) respectively. The model had sensitivity of 0.42 (se 0.12) and specificity of 0.99 (se 0.01) for identifying patients who had ≥90% risk of death at 1 year. Observed mortality was highly consistent with both 3- and 12-month predicted mortality. These four predictive variables can be used in a simple prognostic score that clearly identifies low risk patients (no risk factors, 15% mortality) and high risk patients (3 or 4 risk factors, 97% mortality). Conclusions Simple clinical variables measured on day 21 of mechanical ventilation can identify patients at highest and lowest risk of death from prolonged ventilation. PMID:18552692
Technical aspects and clinical implications of high frequency jet ventilation with a solenoid valve.
Carlon, G C; Miodownik, S; Ray, C; Kahn, R C
1981-01-01
High frequency jet ventilation (HFJV) is an incompletely studied technique of mechanical respiratory support. The authors have built a ventilator based on a solenoid valve, that allows independent selection of respiratory rate and inspiratory/expiratory ratio. The ventilator can be synchronized to the heart rate. Humidification is provided by warm saline dripped in front of the injector nozzle, so that the jet stream itself acts as a nebulizer. Tube diameter, length, and deformability are fundamental determinants of inspiratory flow rate and wave form. Cannula kinking and inadequate humidification were the most significant sources of complications.
Dust control effectiveness of drywall sanding tools.
Young-Corbett, Deborah E; Nussbaum, Maury A
2009-07-01
In this laboratory study, four drywall sanding tools were evaluated in terms of dust generation rates in the respirable and thoracic size classes. In a repeated measures study design, 16 participants performed simulated drywall finishing tasks with each of four tools: (1) ventilated sander, (2) pole sander, (3) block sander, and (4) wet sponge. Dependent variables of interest were thoracic and respirable breathing zone dust concentrations. Analysis by Friedman's Test revealed that the ventilated drywall sanding tool produced significantly less dust, of both size classes, than did the other three tools. The pole and wet sanders produced significantly less dust of both size classes than did the block sander. The block sander, the most commonly used tool in drywall finishing operations, produced significantly more dust of both size classes than did the other three tools. When compared with the block sander, the other tools offer substantial dust reduction. The ventilated tool reduced respirable concentrations by 88% and thoracic concentrations by 85%. The pole sander reduced respirable concentrations by 58% and thoracic by 50%. The wet sander produced reductions of 60% and 47% in the respirable and thoracic classes, respectively. Wet sponge sanders and pole sanders are effective at reducing breathing-zone dust concentrations; however, based on its superior dust control effectiveness, the ventilated sander is the recommended tool for drywall finishing operations.
Kimura, Fumiharu
2016-04-28
Invasive and/or non-invasive mechanical ventilation are most important options of respiratory management in amyotrophic lateral sclerosis. We evaluated the frequency, clinical characteristics, decision-making factors about ventilation and survival analysis of 190 people with amyotrophic lateral sclerosis patients from 1990 until 2013. Thirty-one percentage of patients underwent tracheostomy invasive ventilation with the rate increasing more than the past 20 years. The ratio of tracheostomy invasive ventilation in patients >65 years old was significantly increased after 2000 (25%) as compared to before (10%). After 2010, the standard use of non-invasive ventilation showed a tendency to reduce the frequency of tracheostomy invasive ventilation. Mechanical ventilation prolonged median survival (75 months in tracheostomy invasive ventilation, 43 months in non-invasive ventilation vs natural course, 32 months). The life-extending effects by tracheostomy invasive ventilation were longer in younger patients ≤65 years old at the time of ventilation support than in older patients. Presence of partners and care at home were associated with better survival. Following factors related to the decision to perform tracheostomy invasive ventilation: patients ≤65 years old: greater use of non-invasive ventilation: presence of a spouse: faster tracheostomy: higher progression rate; and preserved motor functions. No patients who underwent tracheostomy invasive ventilation died from a decision to withdraw mechanical ventilation. The present study provides factors related to decision-making process and survival after tracheostomy and help clinicians and family members to expand the knowledge about ventilation.
Fuselage ventilation due to wind flow about a postcrash aircraft
NASA Technical Reports Server (NTRS)
Stuart, J. W.
1980-01-01
Postcrash aircraft fuselage fire development, dependent on the internal and external fluid dynamics is discussed. The natural ventilation rate, a major factor in the internal flow patterns and fire development is reviewed. The flow about the fuselage as affected by the wind and external fire is studied. An analysis was performend which estimated the rates of ventilation produced by the wind for a limited idealized environmental configuration. The simulation utilizes the empirical pressure coefficient distribution of an infinite circular cylinder near a wall with its boundary later flow to represent the atmospheric boundary layer. The resulting maximum ventilation rate for two door size openings, with varying circumferential location in a common 10 mph wind was an order of magnitude greater than the forced ventilation specified in full scale fire testing. The parameter discussed are: (1) fuselage size and shape, (2) fuselage orientation and proximity to the ground, (3) fuselage-openings size and location, (4) wind speed and direction, and (5) induced flow of the external fire plume is recommended. The fire testing should be conducted to a maximum ventilation rate at least an order of magnitude greater than the inflight air conditioning rates.
MacLaren, Robert; Campbell, Jon
2014-04-01
To examine the cost-effectiveness of using histamine receptor-2 antagonist or proton pump inhibitor for stress ulcer prophylaxis. Decision analysis model examining costs and effectiveness of using histamine receptor-2 antagonist or proton pump inhibitor for stress ulcer prophylaxis. Costs were expressed in 2012 U.S. dollars from the perspective of the institution and included drug regimens and the following outcomes: clinically significant stress-related mucosal bleed, ventilator-associated pneumonia, and Clostridium difficile infection. Effectiveness was the mortality risk associated with these outcomes and represented by survival. Costs, occurrence rates, and mortality probabilities were extracted from published data. A simulation model. A mixed adult ICU population. Histamine receptor-2 antagonist or proton pump inhibitor for 9 days of stress ulcer prophylaxis therapy. Output variables were expected costs, expected survival rates, incremental cost, and incremental survival rate. Univariate sensitivity analyses were conducted to determine the drivers of incremental cost and incremental survival. Probabilistic sensitivity analysis was conducted using second-order Monte Carlo simulation. For the base case analysis, the expected cost of providing stress ulcer prophylaxis was $6,707 with histamine receptor-2 antagonist and $7,802 with proton pump inhibitor, resulting in a cost saving of $1,095 with histamine receptor-2 antagonist. The associated mortality probabilities were 3.819% and 3.825%, respectively, resulting in an absolute survival benefit of 0.006% with histamine receptor-2 antagonist. The primary drivers of incremental cost and survival were the assumptions surrounding ventilator-associated pneumonia and bleed. The probabilities that histamine receptor-2 antagonist was less costly and provided favorable survival were 89.4% and 55.7%, respectively. A secondary analysis assuming equal rates of C. difficile infection showed a cost saving of $908 with histamine receptor-2 antagonists, but the survival benefit of 0.0167% favored proton pump inhibitors. Histamine receptor-2 antagonist therapy appears to reduce costs with survival benefit comparable to proton pump inhibitor therapy for stress ulcer prophylaxis. Ventilator-associated pneumonia and bleed are the variables most affecting these outcomes. The uncertainty in the findings justifies a prospective trial.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cain, W.S.; Isseroff, R.; Leaderer, B.P.
1981-04-01
Experiments on occupancy odor addressed the question of why required ventilation rate per occupant increased progressively with increases in the number of persons in a space. In order to investigate ventilation requirements under approximately ideal conditions, we constructed an aluminum-lined environmental chamber with excellent control over environmental conditions and a ventilation system that provided rapid and uniform mixing of air. Psychophysical experiments on occupancy odor explored 47 different combinations of occupancy density, temperature and humidity, and ventilation rate. The experiments collected judgements both from visitors, who smelled air from the chamber only once every few minutes, and from occupants, whomore » remained in the chamber for an hour at a time. The judgements of visitors revealed that occupancy odor increased only gradually over time and rarely reached very high or objectionable levels. Judgements of occupants also revealed rather minor dissatisfaction. Only during combinations of high temperature and humidity did objectionability become more than a minor issue to either group. Experiments on cigarette smoking explored rates of 4, 8, and 16 cigarettes per hour under various environmental conditions and with ventilation rates as high as 68 cfm (34 L.s/sup -1/) per occupant. As soon as occupants lit cigarettes in the chamber, the odor level increased dramatically. At ventilation rates far greater than necessary to control occupancy odor, the odor from cigarette smoking remained quite intense. In general, the odor proved impossible to control adequately even with a ventilation rate of 68 cfm (34 L.s/sup -1/) per occupant (4 occupants) and even when only one occupant smoked at a time. As in the case of occupancy odor, a combination of high temperature and humidity exacerbated the odor problem.« less
Edelson, Dana P.; Eilevstjønn, Joar; Weidman, Elizabeth K.; Retzer, Elizabeth; Vanden Hoek, Terry L.; Abella, Benjamin S.
2009-01-01
Objective Hyperventilation is both common and detrimental during cardiopulmonary resuscitation (CPR). Chest wall impedance algorithms have been developed to detect ventilations during CPR. However, impedance signals are challenged by noise artifact from multiple sources, including chest compressions. Capnography has been proposed as an alternate method to measure ventilations. We sought to assess and compare the adequacy of these two approaches. Methods Continuous chest wall impedance and capnography were recorded during consecutive in-hospital cardiac arrests. Algorithms utilizing each of these data sources were compared to a manually determined “gold standard” reference ventilation rate. In addition, a combination algorithm, which utilized the highest of the impedance or capnography values in any given minute, was similarly evaluated. Results Data were collected from 37 cardiac arrests, yielding 438 min of data with continuous chest compressions and concurrent recording of impedance and capnography. The manually calculated mean ventilation rate was 13.3±4.3/min. In comparison, the defibrillator’s impedance-based algorithm yielded an average rate of 11.3±4.4/min (p=0.0001) while the capnography rate was 11.7±3.7/min (p=0.0009). There was no significant difference in sensitivity and positive predictive value between the two methods. The combination algorithm rate was 12.4±3.5/min (p=0.02), which yielded the highest fraction of minutes with respiratory rates within 2/min of the reference. The impedance signal was uninterpretable 19.5% of the time, compared with 9.7% for capnography. However, the signals were only simultaneously non-interpretable 0.8% of the time. Conclusions Both the impedance and capnography-based algorithms underestimated the ventilation rate. Reliable ventilation rate determination may require a novel combination of multiple algorithms during resuscitation. PMID:20036047
Measurement of changes in respiratory mechanics during partial liquid ventilation using jet pulses.
Schmalisch, Gerd; Schmidt, Mario; Proquitté, Hans; Foitzik, Bertram; Rüdiger, Mario; Wauer, Roland R
2003-05-01
To compare the changes in respiratory mechanics within the breathing cycle in healthy lungs between gas ventilation and partial liquid ventilation using a special forced-oscillation technique. Prospective animal trial. Animal laboratory in a university setting. A total of 12 newborn piglets (age, <12 hrs; mean weight, 725 g). After intubation and instrumentation, lung mechanics of the anesthetized piglets were measured by forced-oscillation technique at the end of inspiration and the end of expiration. The measurements were performed during gas ventilation and 80 mins after instillation of 30 mL/kg perfluorocarbon PF 5080. Brief flow pulses (width, 10 msec; peak flow, 16 L/min) were generated by a jet generator to measure the end-inspiratory and the end-expiratory respiratory input impedance in the frequency range of 4-32 Hz. The mechanical variables resistance, inertance, and compliance were determined by model fitting, using the method of least squares. At least in the lower frequency range, respiratory mechanics could be described adequately by an RIC single-compartment model in all piglets. During gas ventilation, the respiratory variables resistance and inertance did not differ significantly between end-inspiratory and end-expiratory measurements (mean [sd]: 4.2 [0.7] vs. 4.1 [0.6] kPa x L(-1) x sec, 30.0 [3.2] vs. 30.7 [3.1] Pa x L(-1) x sec2, respectively), whereas compliance decreased during inspiration from 14.8 (2.0) to 10.2 (2.4) mL x kPa(-1) x kg(-1) due to a slight lung overdistension. During partial liquid ventilation, the end-inspiratory respiratory mechanics was not different from the end-inspiratory respiratory mechanics measured during gas ventilation. However, in contrast to gas ventilation during partial liquid ventilation, compliance rose from 8.2 (1.0) to 13.0 (3.0) mL x kPa(-1) x kg(-1) during inspiration. During expiration, when perfluorocarbon came into the upper airways, both resistance and inertance increased considerably (mean with 95% confidence interval) by 34.3% (23.1%-45.8%) and 104.1% (96.0%-112.1%), respectively. The changes in the respiratory mechanics within the breathing cycle are considerably higher during partial liquid ventilation compared with gas ventilation. This dependence of lung mechanics from the pulmonary gas volume hampers the comparability of dynamic measurements during partial liquid ventilation, and the magnitude of these changes cannot be detected by conventional respiratory-mechanical analysis using time-averaged variables.
Incidence and Clinical Outcome of Hypophosphatemia in Pediatric Burn Patients.
Leite, Heitor Pons; Pinheiro Nogueira, Larissa Araújo; Teodosio, Ariane Helena Calassa
The objective of this study is to investigate the factors associated with serum phosphate concentrations in severely burned children and whether hypophosphatemia is associated with outcome. Seventy-eight children with a total body surface area of 24% (6.0-68.5) were retrospectively analyzed for serum phosphate concentrations during the first 10 days of stay in the intensive care unit (ICU). The method of generalized estimating equations was used to evaluate the effect of the exposure variables for serum phosphate concentrations during the study period. Outcome variables were the probability of ICU discharge at 30 days and time on mechanical ventilation. Potential explanatory variables for clinical outcome were hypophosphatemia (serum phosphate <3.8 mg/dL for children <2 years and <3.5 mg/dL for older children), age, sex, percent total body surface area burn, inhalation injury, and severe sepsis and/or septic shock. Competing-risk analysis was applied to calculate the probability of ICU discharge at 30 days, and death was assumed as the competing event. The rate of hypophosphatemia was 79.5%. Serum phosphate concentrations were associated with C-reactive protein (coefficient: -0.63; 95% confidence interval [CI]: -0.96 to -0.30; P = .001). Hypophosphatemia was independently associated with a 68% decrease in the probability of ICU discharge at 30 days (subhazard ratio: -0.32; 95% CI: 0.20, 0.53; P = .001) and an increase of 2.9 days in mechanical ventilation (coefficient: 2.91; 95% CI: 1.16, 4.66; P = .001). Serum phosphate concentrations in pediatric burn patients are associated with the magnitude of inflammatory response. Hypophosphatemia is associated with decreased probability of ICU discharge and increased time on mechanical ventilation.
Vissers, Gino; Soar, Jasmeet; Monsieurs, Koenraad G
2017-10-01
The optimal ventilation rate during cardiopulmonary resuscitation (CPR) with a tracheal tube is unknown. We evaluated whether in adults with cardiac arrest and a secure airway (tracheal tube), a ventilation rate of 10min -1 , compared to any other rate during CPR, improves outcomes. A systematic review up to 14 July 2016. We included both adult human and animal studies. A GRADE (Grades of Recommendation, Assessment, Development and Evaluation) approach was used to evaluate the quality of evidence for each outcome. We identified one human observational study with 67 patients and ten animal studies (234 pigs and 30 dogs). All studies carried a high risk of bias. All studies evaluated for return of spontaneous circulation (ROSC). Studies showed no improvement in ROSC with a ventilation rate of 10 min-1 compared to any other rate. The evidence for longer-term outcomes such as survival to discharge and survival with favourable neurological outcome was very limited. A ventilation rate recommendation of 10 min-1 during adult CPR with a tracheal tube and no pauses for chest compression is a very weak recommendation based on very low quality evidence. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhang, Xianming; Wu, Weiliang; Zhu, Yongcheng; Jiang, Ying; Du, Juan; Chen, Rongchang
2016-01-01
It has proved that muscle paralysis was more protective for injured lung in severe acute respiratory distress syndrome (ARDS), but the precise mechanism is not clear. The purpose of this study was to test the hypothesis that abdominal muscle activity during mechanically ventilation increases lung injury in severe ARDS. Eighteen male Beagles were studied under mechanical ventilation with anesthesia. Severe ARDS was induced by repetitive oleic acid infusion. After lung injury, Beagles were randomly assigned into spontaneous breathing group (BIPAPSB) and abdominal muscle paralysis group (BIPAPAP). All groups were ventilated with BIPAP model for 8h, and the high pressure titrated to reached a tidal volume of 6ml/kg, the low pressure was set at 10 cmH2O, with I:E ratio 1:1, and respiratory rate adjusted to a PaCO2 of 35-60 mmHg. Six Beagles without ventilator support comprised the control group. Respiratory variables, end-expiratory volume (EELV) and gas exchange were assessed during mechanical ventilation. The levels of Interleukin (IL)-6, IL-8 in lung tissue and plasma were measured by qRT-PCR and ELISA respectively. Lung injury scores were determined at end of the experiment. For the comparable ventilator setting, as compared with BIPAPSB group, the BIPAPAP group presented higher EELV (427±47 vs. 366±38 ml) and oxygenation index (293±36 vs. 226±31 mmHg), lower levels of IL-6(216.6±48.0 vs. 297.5±71.2 pg/ml) and IL-8(246.8±78.2 vs. 357.5±69.3 pg/ml) in plasma, and lower express levels of IL-6 mRNA (15.0±3.8 vs. 21.2±3.7) and IL-8 mRNA (18.9±6.8 vs. 29.5±7.9) in lung tissues. In addition, less lung histopathology injury were revealed in the BIPAPAP group (22.5±2.0 vs. 25.2±2.1). Abdominal muscle activity during mechanically ventilation is one of the injurious factors in severe ARDS, so abdominal muscle paralysis might be an effective strategy to minimize ventilator-induce lung injury.
Farias, J A; Frutos-Vivar, F; Casado Flores, J; Siaba, A; Retta, A; Fernández, A; Baltodano, A; Ko, I J; Johnson, M; Esteban, A
2006-12-01
Identify factors associated with the survival of pediatric patients who are submitted to mechanical ventilation (MV) for more than 12 hours. International prospective cohort study. It was performed between April 1 and May 31 1999. All patients were followed-up during 28 days or discharge to pediatric intensive care unit (PICU). 36 PICUs from 7 countries. A total of 659 ventilated patients were enrolled but 15 patients were excluded because their vital status was unknown on discharge. Overall in-UCIP mortality rate was 15,6%. Recursive partitioning and logistic regression were used and an outcome model was constructed. The variables significantly associated with mortality were: peak inspiratory pressure (PIP), acute renal failure (ARF), PRISM score and severe hypoxemia (PaO2/FiO2 < 100). The subgroup with best outcome (mortality 7%) included patients who were ventilated with a PIP < 35 cmH2O, without ARF, or PaO2/FiO2 > 100 and PRISM < 27. In patients with a mean PaO2/FiO2 < 100 during MV mortality increased to 26% (OR: 4.4; 95% CI 2.0 to 9.4). Patients with a PRISM score > 27 on admission to PICU had a mortality of 43% (OR: 9.6; 95% CI 4,2 to 25,8). Development of acute renal failure was associated with a mortality of 50% (OR: 12.7; 95% CI 6.3 to 25.7). Finally, the worst outcome (mortality 58%) was for patients with a mean PIP >/= 35 cmH2O (OR 17.3; 95% CI 8.5 to 36.3). In a large cohort of mechanically ventilated pediatric patients we found that severity of illness at admission, high mean PIP, development of acute renal failure and severe hypoxemia over the course of MV were the factors associated with lower survival rate.
NASA Astrophysics Data System (ADS)
Raatschen, W.; Sjoegren, M.
The subject of indoor and outdoor air quality has generated a great deal of attention in many countries. Areas of concern include outgassing of building materials as well as occupant-generated pollutants such as carbon dioxide, moisture, and odors. Progress has also been made towards addressing issues relating to the air tightness of the building envelope. Indoor air quality studies indicate that better control of supply flow rates as well as the air distribution pattern within buildings are necessary. One method of maintaining good indoor air quality without extensive energy consumption is to control the ventilation rate according to the needs and demands of the occupants, or to preserve the building envelope. This is accomplished through the use of demand controlled ventilating (DCV) systems. The specific objective of Annex 18 is to develop guidelines for demand controlled ventilating systems based on state of the art analyses, case studies on ventilation effectiveness, and proposed ventilation rates for different users in domestic, office, and school buildings.
Rowan, Courtney M; Loomis, Ashley; McArthur, Jennifer; Smith, Lincoln S; Gertz, Shira J; Fitzgerald, Julie C; Nitu, Mara E; Moser, Elizabeth As; Hsing, Deyin D; Duncan, Christine N; Mahadeo, Kris M; Moffet, Jerelyn; Hall, Mark W; Pinos, Emily L; Tamburro, Robert F; Cheifetz, Ira M
2018-04-01
The effectiveness of high-frequency oscillatory ventilation (HFOV) in the pediatric hematopoietic cell transplant patient has not been established. We sought to identify current practice patterns of HFOV, investigate parameters during HFOV and their association with mortality, and compare the use of HFOV to conventional mechanical ventilation in severe pediatric ARDS. This is a retrospective analysis of a multi-center database of pediatric and young adult allogeneic hematopoietic cell transplant subjects requiring invasive mechanical ventilation for critical illness from 2009 through 2014. Twelve United States pediatric centers contributed data. Continuous variables were compared using a Wilcoxon rank-sum test or a Kruskal-Wallis analysis. For categorical variables, univariate analysis with logistic regression was performed. The database contains 222 patients, of which 85 subjects were managed with HFOV. Of this HFOV cohort, the overall pediatric ICU survival was 23.5% ( n = 20). HFOV survivors were transitioned to HFOV at a lower oxygenation index than nonsurvivors (25.6, interquartile range 21.1-36.8, vs 37.2, interquartile range 26.5-52.2, P = .046). Survivors were transitioned to HFOV earlier in the course of mechanical ventilation, (day 0 vs day 2, P = .002). No subject survived who was transitioned to HFOV after 1 week of invasive mechanical ventilation. We compared subjects with severe pediatric ARDS treated only with conventional mechanical ventilation versus early HFOV (within 2 d of invasive mechanical ventilation) versus late HFOV. There was a trend toward difference in survival (conventional mechanical ventilation 24%, early HFOV 30%, and late HFOV 9%, P = .08). In this large database of pediatric allogeneic hematopoietic cell transplant subjects who had acute respiratory failure requiring invasive mechanical ventilation for critical illness with severe pediatric ARDS, early use of HFOV was associated with improved survival compared to late implementation of HFOV, and the subjects had outcomes similar to those treated only with conventional mechanical ventilation. Copyright © 2018 by Daedalus Enterprises.
Palomar-Martínez, Mercedes; Sánchez-García, Miguel; Martínez-Alonso, Montserrat; Álvarez-Rodríguez, Joaquín; Lorente, Leonardo; Arias-Rivera, Susana; García, Rosa; Gordo, Federico; Añón, José M.; Jam-Gatell, Rosa; Vázquez-Calatayud, Mónica; Agra, Yolanda
2018-01-01
Objectives: The “Pneumonia Zero” project is a nationwide multimodal intervention based on the simultaneous implementation of a comprehensive evidence-based bundle measures to prevent ventilator-associated pneumonia in critically ill patients admitted to the ICU. Design: Prospective, interventional, and multicenter study. Setting: A total of 181 ICUs throughout Spain. Patients: All patients admitted for more than 24 hours to the participating ICUs between April 1, 2011, and December 31, 2012. Intervention: Ten ventilator-associated pneumonia prevention measures were implemented (seven were mandatory and three highly recommended). The database of the National ICU-Acquired Infections Surveillance Study (Estudio Nacional de Vigilancia de Infecciones Nosocomiales [ENVIN]) was used for data collection. Ventilator-associated pneumonia rate was expressed as incidence density per 1,000 ventilator days. Ventilator-associated pneumonia rates from the incorporation of the ICUs to the project, every 3 months, were compared with data of the ENVIN registry (April–June 2010) as the baseline period. Ventilator-associated pneumonia rates were adjusted by characteristics of the hospital, including size, type (public or private), and teaching (postgraduate) or university-affiliated (undergraduate) status. Measurements and Main Results: The 181 participating ICUs accounted for 75% of all ICUs in Spain. In a total of 171,237 ICU admissions, an artificial airway was present on 505,802 days (50.0% of days of stay in the ICU). A total of 3,474 ventilator-associated pneumonia episodes were diagnosed in 3,186 patients. The adjusted ventilator-associated pneumonia incidence density rate decreased from 9.83 (95% CI, 8.42–11.48) per 1,000 ventilator days in the baseline period to 4.34 (95% CI, 3.22–5.84) after 19–21 months of participation. Conclusions: Implementation of the bundle measures included in the “Pneumonia Zero” project resulted in a significant reduction of more than 50% of the incidence of ventilator-associated pneumonia in Spanish ICUs. This reduction was sustained 21 months after implementation. PMID:29023261
Medrinal, C; Prieur, G; Contal, O; Villiot-Danger, E; Doyle, C; Reychler, G; Quieffin, J
2015-05-01
Many types of interfaces with intentional leaks exist for Non Invasive Ventilation. The purpose of intentional leaks is to remove CO2 from the interface, however the calibration does not allow a sufficiently large flow and rebreathing of CO2 can occur. The aim of this study was to compare the CO2 rinsing capacities of three new generation oronasal masks with intentional leaks (A: Quattro®, [Resmed]; B: Amara® [Respironics]; C: Forma® [Fisher&Paykel]) in healthy subjects. Seventeen healthy volunteers were included in this prospective cross-sectional, randomized, double-blinded trial. Each subject underwent ventilation with a home ventilator (IPAP: 14 cmH2O; EPAP: 4 cmH2O) with each mask consecutively. Transcutaneous capnography (PtcCO2) recordings were carried out throughout the trial and ventilator data (tidal volume, respiratory rate, minute ventilation and unintentional leaks) were also analyzed. Mask comfort was assessed using a visual analog scale (0 to 10). The results showed no differences in PtcCO2 between masks (P=0.82). There were no significant differences in respiratory parameters (tidal volume, P=0.79; respiratory rate, P=0.65; minute ventilation, P=0.12) between masks. The rate of unintentional leaks were significantly lower for Mask A (P=0.016). Subjects rated Mask A and Mask C as more comfortable than Mask B (P=0.041). There was no effect of mask on PtcCO2 in healthy subjects. The mask with the highest comfort rating had not the lowest rate of unintentional leaks.
Leivo, Virpi; Prasauskas, Tadas; Du, Liuliu; Turunen, Mari; Kiviste, Mihkel; Aaltonen, Anu; Martuzevicius, Dainius; Haverinen-Shaughnessy, Ulla
2018-04-15
Impacts of energy retrofits on indoor thermal environment, i.e. temperature (T) and relative humidity (RH), as well as ventilation rates and carbon dioxide (CO 2 ) concentrations, were assessed in 46 Finnish and 20 Lithuanian multi-family buildings, including 39 retrofitted case buildings in Finland and 15 in Lithuania (the remaining buildings were control buildings with no retrofits). In the Finnish buildings, high indoor T along with low RH levels was commonly observed both before and after the retrofits. Ventilation rates (l/s per person) were higher after the retrofits in buildings with mechanical exhaust ventilation than the corresponding values before the retrofits. Measured CO 2 levels were low in vast majority of buildings. In Lithuania, average indoor T levels were low before the retrofits and there was a significant increase in the average T after the retrofits. In addition, average ventilation rate was lower and CO 2 levels were higher after the retrofits in the case buildings (N=15), both in apartments with natural and mixed ventilation. Based on the results, assessment of thermal conditions and ventilation rates after energy retrofits is crucial for optimal indoor environmental quality and energy use. Copyright © 2017 Elsevier B.V. All rights reserved.
Evaluation of a turbine flow meter (Ventilometer Mark 2) in the measurement of ventilation.
Cooper, C B; Harris, N D; Howard, P
1990-01-01
We have evaluated a turbine flow meter (Ventilometer Mark 2, PK Morgan, Kent, UK) at low flow rates and levels of ventilation which are likely to be encountered during exercise in patients with chronic respiratory disease. Pulsatile flows were generated from a volume-cycled mechanical ventilator, the flow wave-form was modified by damping to simulate a human breathing pattern. Comparative measurements of ventilation were made whilst varying tidal volume (VT) from 0.22 to 1.131 and respiratory rate (fR) from 10 to 35 min-1. At lower levels of ventilation the instrument tended to underread especially with increasing fR. The calibration factor must be adjusted to match the level of ventilation if the measurement errors are to be within 5%.
Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France.
Canha, N; Mandin, C; Ramalho, O; Wyart, G; Ribéron, J; Dassonville, C; Hänninen, O; Almeida, S M; Derbez, M
2016-06-01
The aim of this study was to characterize the relationship between Indoor Air Quality (IAQ) and ventilation in French classrooms. Various parameters were measured over one school week, including volatile organic compounds, aldehydes, particulate matter (PM2.5 mass concentration and number concentration), carbon dioxide (CO2 ), air temperature, and relative humidity in 51 classrooms at 17 schools. The ventilation was characterized by several indicators, such as the air exchange rate, ventilation rate (VR), and air stuffiness index (ICONE), that are linked to indoor CO2 concentration. The influences of the season (heating or non-heating), type of school (nursery or elementary), and ventilation on the IAQ were studied. Based on the minimum value of 4.2 l/s per person required by the French legislation for mechanically ventilated classrooms, 91% of the classrooms had insufficient ventilation. The VR was significantly higher in mechanically ventilated classrooms compared with naturally ventilated rooms. The correlations between IAQ and ventilation vary according to the location of the primary source of each pollutant (outdoor vs. indoor), and for an indoor source, whether it is associated with occupant activity or continuous emission. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Factors associated with respiration induced variability in cerebral blood flow velocity.
Coughtrey, H; Rennie, J M; Evans, D H; Cole, T J
1993-01-01
A consecutive cohort of 73 very low birthweight infants was studied to determine the presence or absence of beat to beat variability in the velocity of blood flow in the cerebral circulation and its relation with respiration. One minute epochs of information included recordings of cerebral blood flow velocity estimated with Doppler ultrasound, blood pressure, spontaneous respiratory activity, and ventilator cycling. Fourier transformation was used to resolve the frequencies present within the one minute epochs and to classify the cerebral blood flow velocity as showing the presence or absence of any respiratory associated variability. A total of 249 recordings was made on days 1, 2, 3, and 7. Forty seven infants showed respiratory variability in cerebral blood flow velocity on 97 occasions, usually during the first day of life. The infants with respiratory associated variability were of lower gestational age and when the respiratory associated variability was present they were more likely to be ventilated and receiving higher inspired oxygen; these associations were shown to be independent of gestational age. There was no significant independent association with brain injury, cerebral blood flow velocity (cm/s), or blood pressure (mm Hg). The findings suggest that artificial ventilation may entrain normal respiratory associated variability in the cerebral circulation but do not provide evidence that it is harmful. PMID:8466269
Michetti, Christopher P; Fakhry, Samir M; Ferguson, Pamela L; Cook, Alan; Moore, Forrest O; Gross, Ronald
2012-05-01
Ventilator-associated pneumonia (VAP) rates reported by the National Healthcare Safety Network (NHSN) are used as a benchmark and quality measure, yet different rates are reported from many trauma centers. This multi-institutional study was undertaken to elucidate VAP rates at major trauma centers. VAP rate/1,000 ventilator days, diagnostic methods, institutional, and aggregate patient data were collected retrospectively from a convenience sample of trauma centers for 2008 and 2009 and analyzed with descriptive statistics. At 47 participating Level I and II centers, the pooled mean VAP rate was 17.2 versus 8.1 for NHSN (2006-2008). Hospitals' rates were highly variable (range, 1.8-57.6), with 72.3% being above NHSN's mean. Rates differed based on who determined the rate (trauma service, 27.5; infection control or quality or epidemiology, 11.9; or collaborative effort, 19.9) and the frequency with which VAP was excluded based on aspiration or diagnosis before hospital day 5. In 2008 and 2009, blunt trauma patients had higher VAP rates (17.3 and 17.6, respectively) than penetrating patients (11.0 and 10.9, respectively). More centers used a clinical diagnostic strategy (57%) than a bacteriologic strategy (43%). Patients with VAP had a mean Injury Severity Score of 28.7, mean Intensive Care Unit length of stay of 20.8 days, and a 12.2% mortality rate. 50.5% of VAP patients had a traumatic brain injury. VAP rates at major trauma centers are markedly higher than those reported by NHSN and vary significantly among centers. Available data are insufficient to set benchmarks, because it is questionable whether any one data set is truly representative of most trauma centers. Application of a single benchmark to all centers may be inappropriate, and reliable diagnostic and reporting standards are needed. Prospective analysis of a larger data set is warranted, with attention to injury severity, risk factors specific to trauma patients, diagnostic method used, VAP definitions and exclusions, and reporting guidelines. III, prognostic study.
Kerr, Carolyn L; Windeyer, Claire; Bouré, Ludovic P; Mirakhur, Kuldip K; McDonell, Wayne
2007-12-01
To compare the cardiopulmonary effects of administration of a solution of xylazine, guaifenesin, and ketamine (XGK) or inhaled isoflurane in mechanically ventilated calves undergoing surgery. 13 male calves 2 to 26 days of age. Procedures-In calves in the XGK group, anesthesia was induced (0.5 mL/kg) and maintained (2.5 mL/kg/h) with a combination solution of xylazine (0.1 mg/mL), guaifenesin (50 mg/mL), and ketamine (1.0 mg/mL). For calves in the isoflurane group, anesthesia was induced and maintained with isoflurane in oxygen. The rates of XGK infusion and isoflurane administration were adjusted to achieve suitable anesthetic depth. All calves received 100% oxygen and were mechanically ventilated to maintain end-tidal carbon dioxide concentrations from 35 to 40 mm Hg and underwent laparoscopic bladder surgery through an abdominal approach. Cardiopulmonary variables were measured before induction and at intervals up to 90 minutes after anesthetic induction. The quality of induction was excellent in all calves. The XGK requirements were 0.57 +/- 0.18 mL/kg and 2.70 +/- 0.40 mL/kg/h to induce and maintain anesthesia, respectively. Heart rate was significantly lower than baseline throughout the anesthetic period in the XGK group. Systolic arterial blood pressure was significantly higher in the XGK group, compared with the isoflurane group, from 5 to 90 minutes. Cardiac index was lower than baseline in both groups. Differences between groups in cardiac index and arterial blood gas values were not significant. Administration of XGK resulted in excellent anesthetic induction and maintenance with cardiopulmonary alterations similar to those associated with isoflurane in mechanically ventilated calves.
The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea.
Javaheri, Shahrokh; Goetting, Mark G; Khayat, Rami; Wylie, Paul E; Goodwin, James L; Parthasarathy, Sairam
2011-12-01
This study was conducted to evaluate the therapeutic performance of a new auto Servo Ventilation device (Philips Respironics autoSV Advanced) for the treatment of complex central sleep apnea (CompSA). The features of autoSV Advanced include an automatic expiratory pressure (EPAP) adjustment, an advanced algorithm for distinguishing open versus obstructed airway apnea, a modified auto backup rate which is proportional to subject's baseline breathing rate, and a variable inspiratory support. Our primary aim was to compare the performance of the advanced servo-ventilator (BiPAP autoSV Advanced) with conventional servo-ventilator (BiPAP autoSV) in treating central sleep apnea (CSA). A prospective, multicenter, randomized, controlled trial. Five sleep laboratories in the United States. Thirty-seven participants were included. All subjects had full night polysomnography (PSG) followed by a second night continuous positive airway pressure (CPAP) titration. All had a central apnea index ≥ 5 per hour of sleep on CPAP. Subjects were randomly assigned to 2 full-night PSGs while treated with either the previously marketed autoSV, or the new autoSV Advanced device. The 2 randomized sleep studies were blindly scored centrally. Across the 4 nights (PSG, CPAP, autoSV, and autoSV Advanced), the mean ± 1 SD apnea hypopnea indices were 53 ± 23, 35 ± 20, 10 ± 10, and 6 ± 6, respectively; indices for CSA were 16 ± 19, 19 ± 18, 3 ± 4, and 0.6 ± 1. AutoSV Advanced was more effective than other modes in correcting sleep related breathing disorders. BiPAP autoSV Advanced was more effective than conventional BiPAP autoSV in the treatment of sleep disordered breathing in patients with CSA.
Stecher, Frederik S; Olsen, Jan-Aage; Stickney, Ronald E; Wik, Lars
2008-12-01
There is a need to measure cardiopulmonary resuscitation (CPR) in order to document whether ambulance personnel follow CPR guidelines. Our goal was to do this using defibrillator technology based on changes in transthoracic impedance (TTI) produced by chest compressions and ventilations. 122 incidents of out-of-hospital cardiac arrest between May 2003 and February 2004 were analysed based on data recorded from defibrillators in Oslo EMS. New software was used to analyze chest compressions and ventilations based on changes in thoracic impedance between the defibrillator pads, as well as ECG and other event data. In total, 25+/-14% (varying from 76% to 3%) of the time chest compressions were not performed on patients without spontaneous circulation (NFR=No Flow Ratio). When adjusting for time spent on analysis of ECG, pulse check and defibrillation, NFR was 20+/-13% (varying from 70% to 3%). Mean compressions delivered per minute was 87+/-16 and the compression rate during active compressions was 117+/-9min(-1). Individual variation was 31-117min(-1) (mean) and 95-144min(-1) (active periods). A mean of 14+/-3ventilations/min was recorded, varying from 8 to 26min(-1). Compared with the rest of the episode, the first 5min had a significantly higher proportion of time without chest compressions; 30+/-17% (p<0.001) and significantly lower mean compression and ventilation rates; 80+/-19min(-1) and 12+/-4min(-1), respectively (p<0.001 in both cases). Core CPR values can be measured from TTI signals by using a standard defibrillator and new software. NFR was 25% (20% adjusted) with great rescuer variability.
Increased ventilation by fish leads to a higher risk of parasitism.
Mikheev, Victor N; Pasternak, Anna F; Valtonen, E Tellervo; Taskinen, Jouni
2014-06-23
Fish are common intermediate hosts of trematode cercariae and their gills can potentially serve as important sites of penetration by these larval stages. We experimentally tested the hypothesis that volume of ventilation flow across the gills contributes to acquisition of these parasites by fish. We manipulated the intensity of ventilation by using different oxygen concentrations. Juvenile Oncorhynchus mykiss were individually exposed for 10 minutes to a standard dose of Diplostomum pseudospathaceum cercariae at three levels of oxygen concentration, 30, 60 and 90%. Ventilation amplitude (measured as a distance between left and right operculum), operculum beat rate, and the number of cercariae established in the eyes of fish were recorded. Fish reacted to low oxygen concentration with wider expansion of opercula (but not with increasing beat rate), leading to an increase in ventilation volume. As expected, the intensity of infection increased with decreasing oxygen saturation-probably due to a higher exposure to cercariae caused by increased ventilation under low oxygen concentrations. The number of cercariae acquired by an individual fish was positively correlated with ventilation amplitude and with ventilation volume, but not with operculum beat rate. However, even though the infection rate increased under these circumstances, the proportion of larval trematodes successfully establishing in fish eyes decreased with increasing ventilation volume, suggesting that the high flow velocity, although increasing host exposure to cercarial parasites, may interfere with the ability of these parasites to penetrate their hosts. There was no difference in the behaviour of trematode cercariae exposed to low and high oxygen concentrations. A reduction in oxygen saturation resulted in an increase in ventilation volume across the gills and in doing so an increase in the exposure of fish to cercariae. A significant correlation between ventilation volume and parasitism represents the first experimental evidence that this physiological mechanism generates variation in transmission of parasites to fish hosts. Other factors that modify ventilation flow, e.g. physiological or social stressors, are expected to produce similar effects on the transmission success of the parasites penetrating fish hosts using the gills.
Increased ventilation by fish leads to a higher risk of parasitism
2014-01-01
Background Fish are common intermediate hosts of trematode cercariae and their gills can potentially serve as important sites of penetration by these larval stages. We experimentally tested the hypothesis that volume of ventilation flow across the gills contributes to acquisition of these parasites by fish. We manipulated the intensity of ventilation by using different oxygen concentrations. Methods Juvenile Oncorhynchus mykiss were individually exposed for 10 minutes to a standard dose of Diplostomum pseudospathaceum cercariae at three levels of oxygen concentration, 30, 60 and 90%. Ventilation amplitude (measured as a distance between left and right operculum), operculum beat rate, and the number of cercariae established in the eyes of fish were recorded. Results Fish reacted to low oxygen concentration with wider expansion of opercula (but not with increasing beat rate), leading to an increase in ventilation volume. As expected, the intensity of infection increased with decreasing oxygen saturation—probably due to a higher exposure to cercariae caused by increased ventilation under low oxygen concentrations. The number of cercariae acquired by an individual fish was positively correlated with ventilation amplitude and with ventilation volume, but not with operculum beat rate. However, even though the infection rate increased under these circumstances, the proportion of larval trematodes successfully establishing in fish eyes decreased with increasing ventilation volume, suggesting that the high flow velocity, although increasing host exposure to cercarial parasites, may interfere with the ability of these parasites to penetrate their hosts. There was no difference in the behaviour of trematode cercariae exposed to low and high oxygen concentrations. Conclusion A reduction in oxygen saturation resulted in an increase in ventilation volume across the gills and in doing so an increase in the exposure of fish to cercariae. A significant correlation between ventilation volume and parasitism represents the first experimental evidence that this physiological mechanism generates variation in transmission of parasites to fish hosts. Other factors that modify ventilation flow, e.g. physiological or social stressors, are expected to produce similar effects on the transmission success of the parasites penetrating fish hosts using the gills. PMID:24954703
Night ventilation control strategies in office buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Zhaojun; Yi, Lingli; Gao, Fusheng
2009-10-15
In moderate climates night ventilation is an effective and energy-efficient approach to improve the indoor thermal environment for office buildings during the summer months, especially for heavyweight construction. However, is night ventilation a suitable strategy for office buildings with lightweight construction located in cold climates? In order to answer this question, the whole energy-consumption analysis software EnergyPlus was used to simulate the indoor thermal environment and energy consumption in typical office buildings with night mechanical ventilation in three cities in northern China. The summer outdoor climate data was analyzed, and three typical design days were chosen. The most important factorsmore » influencing night ventilation performance such as ventilation rates, ventilation duration, building mass and climatic conditions were evaluated. When night ventilation operation time is closer to active cooling time, the efficiency of night ventilation is higher. With night ventilation rate of 10 ach, the mean radiant temperature of the indoor surface decreased by up to 3.9 C. The longer the duration of operation, the more efficient the night ventilation strategy becomes. The control strategies for three locations are given in the paper. Based on the optimized strategies, the operation consumption and fees are calculated. The results show that more energy is saved in office buildings cooled by a night ventilation system in northern China than ones that do not employ this strategy. (author)« less
Evaluation of design ventilation requirements for enclosed parking facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayari, A.; Krarti, M.
2000-07-01
This paper proposes a new design approach to determine the ventilation requirements for enclosed parking garages. The design approach accounts for various factors that affect the indoor air quality within a parking facility, including the average CO emission rate, the average travel time, the number of cars, and the acceptable CO level within the parking garage. This paper first describes the results of a parametric analysis based on the design method that was developed. Then the design method is presented to explain how the ventilation flow rate can be determined for any enclosed parking facility. Finally, some suggestions are proposedmore » to save fan energy for ventilating parking garages using demand ventilation control strategies.« less
Bernardi, L; Porta, C; Sleight, P
2006-04-01
To assess the potential clinical use, particularly in modulating stress, of changes in the cardiovascular and respiratory systems induced by music, specifically tempo, rhythm, melodic structure, pause, individual preference, habituation, order effect of presentation, and previous musical training. Measurement of cardiovascular and respiratory variables while patients listened to music. University research laboratory for the study of cardiorespiratory autonomic function. 12 practising musicians and 12 age matched controls. After a five minute baseline, presentation in random order of six different music styles (first for a two minute, then for a four minute track), with a randomly inserted two minute pause, in either sequence. Breathing rate, ventilation, carbon dioxide, RR interval, blood pressure, mid-cerebral artery flow velocity, and baroreflex. Ventilation, blood pressure, and heart rate increased and mid-cerebral artery flow velocity and baroreflex decreased with faster tempi and simpler rhythmic structures compared with baseline. No habituation effect was seen. The pause reduced heart rate, blood pressure, and minute ventilation, even below baseline. An order effect independent of style was evident for mid-cerebral artery flow velocity, indicating a progressive reduction with exposure to music, independent of style. Musicians had greater respiratory sensitivity to the music tempo than did non-musicians. Music induces an arousal effect, predominantly related to the tempo. Slow or meditative music can induce a relaxing effect; relaxation is particularly evident during a pause. Music, especially in trained subjects, may first concentrate attention during faster rhythms, then induce relaxation during pauses or slower rhythms.
EPA has released a draft report entitled, Metabolically-Derived Human Ventilation Rates: A Revised Approach Based Upon Oxygen Consumption Rates, for independent external peer review and public comment. NCEA published the Exposure Factors Handbook in 1997. This comprehens...
Kollef, Marin H; Rello, Jordi; Cammarata, Sue K; Croos-Dabrera, Rodney V; Wunderink, Richard G
2004-03-01
To assess the effect of baseline variables, including treatment, on clinical cure and survival rates in patients with Gram-positive, ventilator-associated pneumonia (VAP). Retrospective analysis of two randomized, double-blind studies. Multinational study with 134 sites. 544 patients with suspected Gram-positive VAP, including 264 with documented Gram-positive VAP and 91 with methicillin-resistant S. aureus (MRSA) VAP. Linezolid 600 mg or vancomycin 1 g every 12 h for 7-21 days, each with aztreonam. Clinical cure rates assessed 12-28 days after the end of therapy and excluding indeterminate or missing outcomes significantly favored linezolid in the Gram-positive and MRSA subsets. Logistic regression showed that linezolid was an independent predictor of clinical cure with odds ratios of 1.8 for all patients, 2.4 for Gram-positive VAP, and 20.0 for MRSA VAP. Kaplan-Meier survival rates favored linezolid in the MRSA subset. Logistic regression showed that linezolid was an independent predictor of survival with odds ratios of 1.6 for all patients, 2.6 for Gram-positive VAP, and 4.6 for MRSA VAP. Initial linezolid therapy was associated with significantly better clinical cure and survival rates than was initial vancomycin therapy in patients with MRSA VAP.
Ventilation Processes in a Three-Dimensional Street Canyon
NASA Astrophysics Data System (ADS)
Nosek, Štěpán; Kukačka, Libor; Kellnerová, Radka; Jurčáková, Klára; Jaňour, Zbyněk
2016-05-01
The ventilation processes in three different street canyons of variable roof geometry were investigated in a wind tunnel using a ground-level line source. All three street canyons were part of an urban-type array formed by courtyard-type buildings with pitched roofs. A constant roof height was used in the first case, while a variable roof height along the leeward or windward walls was simulated in the two other cases. All street-canyon models were exposed to a neutrally stratified flow with two approaching wind directions, perpendicular and oblique. The complexity of the flow and dispersion within the canyons of variable roof height was demonstrated for both wind directions. The relative pollutant removals and spatially-averaged concentrations within the canyons revealed that the model with constant roof height has higher re-emissions than models with variable roof heights. The nomenclature for the ventilation processes according to quadrant analysis of the pollutant flux was introduced. The venting of polluted air (positive fluctuations of both concentration and velocity) from the canyon increased when the wind direction changed from perpendicular to oblique, irrespective of the studied canyon model. Strong correlations (>0.5) between coherent structures and ventilation processes were found at roof level, irrespective of the canyon model and wind direction. This supports the idea that sweep and ejection events of momentum bring clean air in and detrain the polluted air from the street canyon, respectively.
NASA Astrophysics Data System (ADS)
Pérez-Asensio, José N.; Cacho, Isabel; Frigola, Jaime; Pena, Leopoldo D.; Sierro, Francisco J.; Asioli, Alessandra; Kuhlmann, Jannis; Huhn, Katrin
2017-04-01
Paleoenvironmental and paleoceanographic changes in the western Mediterranean are reconstructed for the last 24 ka using a combination of benthic foraminiferal assemblages and geochemical proxies measured on benthic foraminiferal shells (Mg/Ca-deep water temperatures and stable isotopes). The studied materials are sediment cores HER-GC-UB06 and MD95-2043recovered at 946 m and 1841 m, respectively, from the Alboran Sea. At present, both core sites are bathed by the Western Mediterranean Deep Water (WMDW), although UB06 core is close to the boundary with the overlying Levantine Intermediate Water (LIW). Therefore, past variability of both water masses can potentially be recorded by the benthic foraminiferal proxies from the studied sites. Benthic foraminiferal assemblages and geochemical data show fluctuations in bottom-water ventilation, organic matter accumulation and deep-water temperatures related to WMDW and LIW circulation. During the glacial interval, an alternation of events showing better ventilation (higher abundance of Cibicides pachyderma) with lower temperatures and events of warmer deep water temperatures with poorer ventilation (Nonionella iridea assemblage, lower abundance of C. pachyderma) are observed. This variability might reflect stronger WMDW formation during the Last Glacial Maximum (LGM) and Heinrich Stadial 1. During the Bølling-Allerød and Younger Dryas (YD) periods, cold temperatures and the lowest oxygenation rates are recorded coinciding with the highest abundance of deep infaunal taxa on both UB06 and MD95-2043 cores. This interval was coetaneous to the deposition of an Organic Rich Layer in the Alboran Sea. However, a re-ventilation trend started at the end of the YD in the shallower site (UB06 core) whereas low-oxygen conditions prevailed until the end of the early Holocene in the deep site (MD95-2043 core). During the early Holocene a significant deep water temperature increase occurred at the shallower site suggesting the replacement of WMDW by warmer water mass, likely LIW. In the middle Holocene, highly variable bottom-water oxygenation and temperatures are observed showing warmer deep waters with less oxygen content (higher deep and intermediate infaunal abundances). The late Holocene (last 4 ka) was characterized by slightly cooler deep water temperatures and enhanced oxygen levels supporting that WMDW became dominant at the shallower site. These observations reveal that Mediterranean thermohaline system has been highly variable during the studied period supporting its high sensitivity to changing climate conditions. These results open a new insight into the Mediterranean sensitivity to Holocene climate variability.
Investigation of Condensing Ice Heat Exchangers for MTSA Technology Development
NASA Technical Reports Server (NTRS)
Padilla, Sebastian; Powers, Aaron; Ball, Tyler; Iacomini, Christie; Paul, Heather, L.
2008-01-01
Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal, carbon dioxide (CO2) and humidity control for a Portable Life Support Subsystem (PLSS). Metabolically-produced CO2 present in the ventilation gas of a PLSS is collected using a CO2selective adsorbent via temperature swing adsorption. The temperature swing is initiated through cooling to well below metabolic temperatures. Cooling is achieved with a sublimation heat exchanger using water or liquid carbon dioxide (LCO2) expanded below sublimation temperature when exposed to low pressure or vacuum. Subsequent super heated vapor, as well as additional coolant, is used to further cool the astronaut. The temperature swing on the adsorbent is then completed by warming the adsorbent with a separate condensing ice heat exchanger (CIHX) using metabolic heat from moist ventilation gas. The condensed humidity in the ventilation gas is recycled at the habitat. The water condensation from the ventilation gas is a significant heat transfer mechanism for the warming of the adsorbent bed because it represents as much as half of the energy potential in the moist ventilation gas. Designing a heat exchanger to efficiently transfer this energy to the adsorbent bed and allow the collection of the water is a challenge since the CIHX will operate in a temperature range from 210K to 280K. The ventilation gas moisture will first freeze and then thaw, sometimes existing in three phases simultaneously. A NASA Small Business Innovative Research (SBIR) Phase 1 contract was performed to investigate condensing and icing as applied to MTSA to enable higher fidelity modeling and assess the impact of geometry variables on CIHX performance for future CIHX design optimization. Specifically, a design tool was created using analytical relations to explore the complex, interdependent design space of a condensing ice heat exchanger. Numerous variables were identified as having nontrivial contributions to performance such as hydraulic diameter, heat exchanger effectiveness, ventilation gas mass flow rate and surface roughness. Using this tool, four test articles were designed and manufactured to map to a full MTSA subassembly (the adsorbent bed, the sublimation heat exchanger for cooling and the condensing ice heat exchanger for warming). The design mapping considered impacts due to CIHX geometry as well as subassembly impacts such as thermal mass and thermal resistance through the adsorbent bed. The test articles were tested at simulated PLSS ventilation loop temperature, moisture content and subambient pressure. Ice accumulation and melting were observed. Data and test observations were analyzed to identify drivers of the condensing ice heat exchanger performance. This paper will discuss the analytical models, the test article designs, and testing procedures. Testing issues will be discussed to better describe data and share lessons learned. Data analysis and subsequent conclusions will be presented.
Decisional responsibility for mechanical ventilation and weaning: an international survey
2011-01-01
Introduction Optimal management of mechanical ventilation and weaning requires dynamic and collaborative decision making to minimize complications and avoid delays in the transition to extubation. In the absence of collaboration, ventilation decision making may be fragmented, inconsistent, and delayed. Our objective was to describe the professional group with responsibility for key ventilation and weaning decisions and to examine organizational characteristics associated with nurse involvement. Methods A multi-center, cross-sectional, self-administered survey was sent to nurse managers of adult intensive care units (ICUs) in Denmark, Germany, Greece, Italy, Norway, Switzerland, Netherlands and United Kingdom (UK). We summarized data as proportions (95% confidence intervals (CIs)) and calculated odds ratios (OR) to examine ICU organizational variables associated with collaborative decision making. Results Response rates ranged from 39% (UK) to 92% (Switzerland), providing surveys from 586 ICUs. Interprofessional collaboration (nurses and physicians) was the most common approach to initial selection of ventilator settings (63% (95% CI 59 to 66)), determination of extubation readiness (71% (67 to 75)), weaning method (73% (69 to 76)), recognition of weaning failure (84% (81 to 87)) and weaning readiness (85% (82 to 87)), and titration of ventilator settings (88% (86 to 91)). A nurse-to-patient ratio other than 1:1 was associated with decreased interprofessional collaboration during titration of ventilator settings (OR 0.2, 95% CI 0.1 to 0.6), weaning method (0.4 (0.2 to 0.9)), determination of extubation readiness (0.5 (0.2 to 0.9)) and weaning failure (0.4 (0.1 to 1.0)). Use of a weaning protocol was associated with increased collaborative decision making for determining weaning (1.8 (1.0 to 3.3)) and extubation readiness (1.9 (1.2 to 3.0)), and weaning method (1.8 (1.1 to 3.0). Country of ICU location influenced the profile of responsibility for all decisions. Automated weaning modes were used in 55% of ICUs. Conclusions Collaborative decision making for ventilation and weaning was employed in most ICUs in all countries although this was influenced by nurse-to-patient ratio, presence of a protocol, and varied across countries. Potential clinical implications of a lack of collaboration include delayed adaptation of ventilation to changing physiological parameters, and delayed recognition of weaning and extubation readiness resulting in unnecessary prolongation of ventilation. PMID:22169094
Wastila, Lisa J; Farber, Neil J
2014-05-01
There have been no studies to date that examine physicians' decisions to withdraw life-sustaining treatment for patients based on their surrogates' financial gain. The authors' objective was to ascertain physician attitudes about withdrawing life-sustaining treatment when financial considerations are involved. A survey was developed and pretested containing eight scenarios in which a terminally ill patient's spouse had a decision to make regarding withdrawal of the ventilator, which was deemed medically futile. Nested variables included agreement or disagreement between the spouse and patient, decision to withdraw or continue the ventilator, and financial gain or no financial gain for the spouse. The authors surveyed all internal medicine residents at the University of California, San Diego in the autumn of 2011 and winter of 2012. The responses on each of the three variables for which respondents were likely to withdraw the ventilator were analyzed via student's t-tests. Residents were more likely to withdraw the ventilator when requested to do so than when it was requested to be continued. They were also more likely to withdraw the ventilator when there was agreement in the decision between the spouse and the patient. Residents were more likely to withdraw the ventilator when the spouse would not benefit financially. Internal medicine residents make some decisions about whether to withdraw life-sustaining treatment based on financial considerations. There needs to be ongoing communication with residents about end-of-life decisions where conflicts may exist between the surrogate decision makers and patients or physicians.
Place of death in patients with amyotrophic lateral sclerosis.
Escarrabill, J; Vianello, A; Farrero, E; Ambrosino, N; Martínez Llorens, J; Vitacca, M
2014-01-01
Amyotrophic lateral sclerosis (ALS) is a degenerative neurological disorder that affects motor neurons. Involvement of respiratory muscles causes the failure of the ventilator pump with more or less significant bulbar troubles. ALS course is highly variable but, in most cases, this disease entails a very significant burden for patients and caregivers, especially in the end-of-life period. In order to analyze the characteristics of ALS patients who die at home (DH) and in hospital (DHosp) and to study the variability of clinical practice, a retrospective medical records analysis was performed (n=77 from five hospitals). time elapsed since the onset of symptoms and the beginning of ventilation, characteristics of ventilation (device, mask and hours/day), and support devices and procedures. In all, 14% of patients were ventilated by tracheotomy. From the analysis, 57% of patients were of DH. Mean time since the onset of symptoms was 35.93±25.89 months, significantly shorter in patients who DHosp (29.28±19.69 months) than DH (41.12±29.04) (p=0.044). The percentage of patients with facial ventilation is higher in DHosp (11.4% vs 39.4%, p<0.005). DH or not is related to a set of elements in which health resources, physician attitudes and support resources in the community play a role in the decision-making process. There is great variability between countries and between hospitals in the same country. Given the variability of circumstances in each territory, the place of death in ALS might not be the most important element; more important are the conditions under which the process unfolds. Copyright © 2013 Sociedade Portuguesa de Pneumologia. Published by Elsevier España. All rights reserved.
Morgenroth, S; Thomas, J; Cannizzaro, V; Weiss, M; Schmidt, A R
2018-03-01
Spirometric monitoring provides precise measurement and delivery of tidal volumes within a narrow range, which is essential for lung-protective strategies that aim to reduce morbidity and mortality in mechanically-ventilated patients. Conventional anaesthesia ventilators include inbuilt spirometry to monitor inspiratory and expiratory tidal volumes. The GE Aisys CS 2 anaesthesia ventilator allows additional near-patient spirometry via a sensor interposed between the proximal end of the tracheal tube and the respiratory tubing. Near-patient and inbuilt spirometry of two different GE Aisys CS 2 anaesthesia ventilators were compared in an in-vitro study. Assessments were made of accuracy and variability in inspiratory and expiratory tidal volume measurements during ventilation of six simulated paediatric lung models using the ASL 5000 test lung. A total of 9240 breaths were recorded and analysed. Differences between inspiratory tidal volumes measured with near-patient and inbuilt spirometry were most significant in the newborn setting (p < 0.001), and became less significant with increasing age and weight. During expiration, tidal volume measurements with near-patient spirometry were consistently more accurate than with inbuilt spirometry for all lung models (p < 0.001). Overall, the variability in measured tidal volumes decreased with increasing tidal volumes, and was smaller with near-patient than with inbuilt spirometry. The variability in measured tidal volumes was higher during expiration, especially with inbuilt spirometry. In conclusion, the present in-vitro study shows that measurements with near-patient spirometry are more accurate and less variable than with inbuilt spirometry. Differences between measurement methods were most significant in the smallest patients. We therefore recommend near-patient spirometry, especially for neonatal and paediatric patients. © 2018 The Association of Anaesthetists of Great Britain and Ireland.
Volume guarantee ventilation during surgical closure of patent ductus arteriosus.
Keszler, Martin; Abubakar, Kabir
2015-01-01
Surgical closure of patent ductus arteriosus (PDA) is associated with adverse outcomes. Surgical exposure requires retraction of the lung, resulting in decreased aeration and compliance. Optimal respiratory support for PDA surgery is unknown. Experience with volume guarantee (VG) ventilation at our institution led us to hypothesize that surgery would be better tolerated with automatic adjustment of pressure by VG to maintain tidal volume (VT) during retraction. The objective of this study was to describe ventilator support, VT, and oxygenation of infants supported with VG during PDA surgery. Ventilator variables, oxygen saturation, and heart rate were recorded during PDA surgery in a convenience sample of infants during PDA closure on VG. Pressure limit increased 11% and set VT was 26% lower during lung retraction. Fentanyl and pancuronium/vecuronium were used for anesthesia/muscle relaxation. Longitudinal data were analyzed by analysis of variance for repeated measures. Seven infants, 25.4 ± 1.5 weeks and 723 ± 141 g, underwent closure of PDA on VG at a mean age 29.9 days. No air leak, bradycardia, or death occurred. Target VT was maintained with a modest increase in inflation pressure. Oxygenation remained adequate. VG avoided hypoxemia and maintained adequate VT with only a modest increase in peak inflation pressure and thus may be a useful mode during PDA surgery. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Siddiqui, Muhammad-Mujtaba Ali; Paras, Iftikhar; Jalal, Anjum
2012-09-01
To identify the risk factors for prolonged invasive mechanical ventilation after open heart surgery in Pakistan. This study is based on retrospective analysis of database. We conducted study of all patients who underwent open heart surgery at CPE Institute of Cardiology, Multan from March 2009 to May 2011. The data was retrieved from the database in the form of electronic spreadsheet which was then analyzed using SPSS software. The patients with incomplete data entries were removed from the analysis resulting in a set of 1,617 patients. The data of each patient consisted of 65 preoperative, operative and postoperative variables. The data was summarized as means, medians and standard deviations for numeric variables and frequencies and percentages or categoric variables. These risk factors were compared using Chi-sqaure test. Their ODDs ratios and 95% confidence intervals of ODD's Ratios and P values were calculated. Out of a total of 1,617 patients, 77 patients (4.76%) had prolonged ventilation for a cumulated duration of more than over 24 hours. Preoperative renal failure, emphysema, low EF (<30%), urgent operation, preoperative critical state, prolonged bypass time, prolonged cross clamp time, complex surgical procedures and peri-operative myocardial infarction were found to be risk factors for PIMV. Old age, female gender, advanced ASA class, advanced NYHA class, diabetes mellitus, smoking, history of COPD, redo surgery, left main stenosis, obesity and use of intra-aortic balloon pump were not found to have significant ODDs ratios for PIMV. The patients with prolonged ventilation had significantly high mortality i.e. 32.47% while the normal ventilation group had 0.32% overall mortality. Many of the previously considered risk factors for prolonged ventilation after open heart study are no more significant risk factors. However, prolonged ventilation continues to be associated with very high mortality.
Bruce, Margaret C; Bruce, Eugene N
2006-04-01
To better understand factors that influence carbon monoxide (CO) washout rates, we utilized a multicompartment mathematical model to predict rates of CO uptake, distribution in vascular and extravascular (muscle vs. other soft tissue) compartments, and washout over a range of exposure and washout conditions with varied subject-specific parameters. We fitted this model to experimental data from 15 human subjects, for whom subject-specific parameters were known, multiple washout carboxyhemoglobin (COHb) levels were available, and CO exposure conditions were identical, to investigate the contributions of exposure conditions and individual variability to CO washout from blood. We found that CO washout from venous blood was biphasic and that postexposure times at which COHb samples were obtained significantly influenced the calculated CO half times (P < 0.0001). The first, more rapid, phase of CO washout from the blood reflected the loss of CO to the expired air and to a slow uptake by the muscle compartment, whereas the second, slower washout phase was attributable to CO flow from the muscle compartment back to the blood and removal from blood via the expired air. When the model was used to predict the effects of varying exposure conditions for these subjects, the CO exposure duration, concentration, peak COHb levels, and subject-specific parameters each influenced washout half times. Blood volume divided by ventilation correlated better with half-time predictions than did cardiac output, muscle mass, or ventilation, but it explained only approximately 50% of half-time variability. Thus exposure conditions, COHb sampling times, and individual parameters should be considered when estimating CO washout rates for poisoning victims.
Dynamic evaluation of airflow rates for a variable air volume system serving an open-plan office.
Mai, Horace K W; Chan, Daniel W T; Burnett, John
2003-09-01
In a typical air-conditioned office, the thermal comfort and indoor air quality are sustained by delivering the amount of supply air with the correct proportion of outdoor air to the breathing zone. However, in a real office, it is not easy to measure these airflow rates supplied to space, especially when the space is served by a variable air volume (VAV) system. The most accurate method depends on what is being measured, the details of the building and types of ventilation system. The constant concentration tracer gas method as a means to determine ventilation system performance, however, this method becomes more complicated when the air, including the tracer gas is allowed to recirculate. An accurate measurement requires significant resource support in terms of instrumentation set up and also professional interpretation. This method deters regular monitoring of the performance of an airside systems by building managers, and hence the indoor environmental quality, in terms of thermal comfort and indoor air quality, may never be satisfactory. This paper proposes a space zone model for the calculation of all the airflow parameters based on tracer gas measurements, including flow rates of outdoor air, VAV supply, return space, return and exfiltration. Sulphur hexafluoride (SF6) and carbon dioxide (CO2) are used as tracer gases. After using both SF6 and CO2, the corresponding results provide a reference to justify the acceptability of using CO2 as the tracer gas. The validity of using CO2 has the significance that metabolic carbon dioxide can be used as a means to evaluate real time airflow rates. This approach provides a practical protocol for building managers to evaluate the performance of airside systems.
NASA Astrophysics Data System (ADS)
Moschandreas, D. J.; Vuilleumier, K. L.
Prior to this study, indoor air constituent levels and ventilation rates of hospitality environments had not been measured simultaneously. This investigation measured indoor Environmental Tobacco Smoke-related (ETS-related) constituent levels in two restaurants, a billiard hall and a casino. The objective of this study was to characterize ETS-related constituent levels inside hospitality environments when the ventilation rates satisfy the requirements of the ASHRAE 62-1989 Ventilation Standard. The ventilation rate of each selected hospitality environment was measured and adjusted. The study advanced only if the requirements of the ASHRAE 62-1989 Ventilation Standard - the pertinent standard of the American Society of Heating, Refrigeration and Air Conditioning Engineers - were satisfied. The supply rates of outdoor air and occupant density were measured intermittently to assure that the ventilation rate of each facility satisfied the standard under occupied conditions. Six ETS-related constituents were measured: respirable suspended particulate (RSP) matter, fluorescent particulate matter (FPM, an estimate of the ETS particle concentrations), ultraviolet particulate matter (UVPM, a second estimate of the ETS particle concentrations), solanesol, nicotine and 3-ethenylpyridine (3-EP). ETS-related constituent levels in smoking sections, non-smoking sections and outdoors were sampled daily for eight consecutive days at each hospitality environment. This study found that the difference between the concentrations of ETS-related constituents in indoor smoking and non-smoking sections was statistically significant. Differences between indoor non-smoking sections and outdoor ETS-related constituent levels were identified but were not statistically significant. Similarly, differences between weekday and weekend evenings were identified but were not statistically significant. The difference between indoor smoking sections and outdoors was statistically significant. Most importantly, ETS-related constituent concentrations measured indoors did not exceed existing occupational standards. It was concluded that if the measured ventilation rates of the sampled facilities satisfied the ASHRAE 62-1989 Ventilation Standard requirements, the corresponding ETS-related constituents were measured at concentrations below known harmful levels as specified by the American Conference of Governmental Industrial Hygiene (ACGIH).
NASA Astrophysics Data System (ADS)
Demmers, T. G. M.; Burgess, L. R.; Short, J. L.; Phillips, V. R.; Clark, J. A.; Wathes, C. M.
A method has been developed to measure the emission rate of ammonia from naturally ventilated U.K. livestock buildings. The method is based on measurements of ammonia concentration and estimates of the ventilation rate of the building by continuous release of carbon monoxide tracer within the building. The tracer concentration is measured at nine positions in openings around the perimeter of the building, as well as around a ring sampling line. Two criteria were evaluated to decide whether, at any given time, a given opening in the building acted as an air inlet or as an air outlet. Carbon monoxide concentration difference across an opening was found to be a better criterion than the temperature difference across the opening. Ammonia concentrations were measured continuously at the sampling points using a chemiluminescence analyser. The method was applied to a straw-bedded beef unit and to a slurry-based dairy unit. Both buildings were of space-boarded construction. Ventilation rates estimated by the ring line sample were consistently higher than by the perimeter samples. During calm weather, the ventilation estimates by both samples were similar (10-20 air changes h -1). However, during windy conditions (>5 m s -1) the ventilation rate was overestimated by the ring line sample (average 100 air changes h -1) compared to the perimeter samples (average 50 air changes h -1). The difference was caused by incomplete mixing of the tracer within the building. The ventilation rate estimated from the perimeter samples was used for the calculation of the emission rate. Preliminary estimates of the ammonia emission factor were 6.0 kg NH 3 (500 kg live-weight) -1 (190 d) -1 for the slurry-based dairy unit and 3.7 for the straw-bedded beef unit.
Lenz, G; Heipertz, W; Leidig, E; Madee, S
1986-06-01
Monitoring of ventilation serves to ensure adequate alveolar ventilation and arterial oxygenation, and to avoid pulmonary damage due to mechanical ventilation. Basic clinical monitoring, i.e., inspection, auscultation (including precordial or oesophageal stethoscope) and monitoring of heart rate and blood pressure, is mandatory. Mechanical ventilation is monitored by ventilation pressures (peak pressure, plateau pressure and endexpiratory pressure), ventilation volumes (measured at the in/expiratory valve of the respirator and by hot-wire anemometry at the tube connector), ventilation rate, and inspiratory oxygen concentration (FiO2). Alveolar ventilation should be continuously and indirectly recorded by capnometry (pECO2) and by measurement of transcutaneous pCO2 (tcpCO2), whereas oxygenation is determined via measurement of transcutaneous pO2 (tcpO2). Invasive monitoring of gas exchange is essential in prolonged or intrathoracic interventions as well as in neonates with cardiopulmonary problems. paCO2 may be estimated by capillary or venous blood gas analysis; arterial blood gas analysis is required for exact determination of paCO2 as well as arteriocutaneous pCO2 (atcDCO2) and arterio-end-expiratory (aEDCO2) gradients.
Effect of outside air ventilation rate on VOC concentrations and emissions in a call center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodgson, A.T.; Faulkner, D.; Sullivan, D.P.
2002-01-01
A study of the relationship between outside air ventilation rate and concentrations of VOCs generated indoors was conducted in a call center. Ventilation rates were manipulated in the building's four air handling units (AHUs). Concentrations of VOCs in the AHU returns were measured on 7 days during a 13-week period. Indoor minus outdoor concentrations and emission factors were calculated. The emission factor data was subjected to principal component analysis to identify groups of co-varying compounds based on source type. One vector represented emissions of solvents from cleaning products. Another vector identified occupant sources. Direct relationships between ventilation rate and concentrationsmore » were not observed for most of the abundant VOCs. This result emphasizes the importance of source control measures for limiting VOC concentrations in buildings.« less
THE EFFECT OF VENTILATION ON EMISSION RATES OF WOOD FINISHING MATERIALS
The rate of emission of organic compounds from building materials varies according to: type of material, material loading (area of material/volume of room), compound emitted, temperature, humidity, and ventilation rate. For some compounds and materials (e.g., formaldehyde from pa...
Kruppa, B; Rüden, H
1993-05-01
The question was if a reduction of airborne particles and bacteria in conventionally (turbulently), ventilated operating theatres in comparison to Laminar-Airflow (LAF) operating theatres does occur at high air-exchange-rates. Within the framework of energy consumption measures the influence of air-exchange-rates on airborne particle and bacteria concentrations was determined in two identical operating theatres with conventional ventilation (wall diffusor panel) at the air-exchange-rates 7.5, 10, 15 and 20/h without surgical activity. This was established by means of the statistical procedure of analysis of variance. Especially for the comparison of the air-exchange-rates 7.5 and 15/h statistical differences were found for airborne particle concentrations in supply and ambient air. Concerning airborne bacteria concentrations no differences were found among the various air-exchange-rates. Explanation of variance is quite high for non-viable particles (supply air: 37%, ambient air: 81%) but negligible for viable particles (bacteria) with values below 15%.
Susceptibility to ventilator induced lung injury is increased in senescent rats
2013-01-01
Introduction The principal mechanisms of ventilator induced lung injury (VILI) have been investigated in numerous animal studies. However, prospective data on the effect of old age on VILI are limited. Under the hypothesis that susceptibility to VILI is increased in old age, we investigated the pulmonary and extrapulmonary effects of mechanical ventilation with high tidal volume (VT) in old compared to young adult animals. Interventions Old (19.1 ± 3.0 months) and young adult (4.4 ± 1.3 months) male Wistar rats were anesthetized and mechanically ventilated (positive end-expiratory pressure 5 cmH2O, fraction of inspired oxygen 0.4, respiratory rate 40/minute) with a tidal volume (VT) of either 8, 16 or 24 ml/kg for four hours. Respiratory and hemodynamic variables, including cardiac output, and markers of systemic inflammation were recorded throughout the ventilation period. Lung histology and wet-to-dry weight ratio, injury markers in lung lavage and respiratory system pressure-volume curves were assessed post mortem. Basic pulmonary characteristics were assessed in non-ventilated animals. Results Compared to young adult animals, high VT (24 ml/kg body weight) caused more lung injury in old animals as indicated by decreased oxygenation (arterial oxygen tension (PaO2): 208 ± 3 vs. 131 ± 20 mmHg; P <0.05), increased lung wet-to-dry-weight ratio (5.61 ± 0.29 vs. 7.52 ± 0.27; P <0.05), lung lavage protein (206 ± 52 mg/l vs. 1,432 ± 101; P <0.05) and cytokine (IL-6: 856 ± 448 vs. 3,283 ± 943 pg/ml; P <0.05) concentration. In addition, old animals ventilated with high VT had more systemic inflammation than young animals (IL-1β: 149 ± 44 vs. 272 ± 36 pg/ml; P <0.05 - young vs. old, respectively). Conclusions Ventilation with unphysiologically large tidal volumes is associated with more lung injury in old compared to young rats. Aggravated pulmonary and systemic inflammation is a key finding in old animals developing VILI. PMID:23710684
Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto
2014-01-01
Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM.
NASA Astrophysics Data System (ADS)
Ma, Kai; Li, Jian; Yun, Yichong
2018-03-01
The article first introduces the merits of serial communication in the PLC to the variable frequency speed regulation system of mine local ventilator, and then sets up a hardware application development platform of PLC and inverter based on RS-485 communication technology, next presents communication initialization of the PLC and Inverter. Finally according to the control requirements, PLC send run operation & monitoring instruction to Inverter, realizes the serial communication control between the PLC and Inverter.
Irminger Sea deep convection injects oxygen and anthropogenic carbon to the ocean interior
Fröb, F.; Olsen, A.; Våge, K.; Moore, G. W. K.; Yashayaev, I.; Jeansson, E.; Rajasakaren, B.
2016-01-01
Deep convection in the subpolar North Atlantic ventilates the ocean for atmospheric gases through the formation of deep water masses. Variability in the intensity of deep convection is believed to have caused large variations in North Atlantic anthropogenic carbon storage over the past decades, but observations of the properties during active convection are missing. Here we document the origin, extent and chemical properties of the deepest winter mixed layers directly observed in the Irminger Sea. As a result of the deep convection in winter 2014–2015, driven by large oceanic heat loss, mid-depth oxygen concentrations were replenished and anthropogenic carbon storage rates almost tripled compared with Irminger Sea hydrographic section data in 1997 and 2003. Our observations provide unequivocal evidence that ocean ventilation and anthropogenic carbon uptake take place in the Irminger Sea and that their efficiency can be directly linked to atmospheric forcing. PMID:27786263
Modeled occupational exposures to gas-phase medical laser-generated air contaminants.
Lippert, Julia F; Lacey, Steven E; Jones, Rachael M
2014-01-01
Exposure monitoring data indicate the potential for substantive exposure to laser-generated air contaminants (LGAC); however the diversity of medical lasers and their applications limit generalization from direct workplace monitoring. Emission rates of seven previously reported gas-phase constituents of medical laser-generated air contaminants (LGAC) were determined experimentally and used in a semi-empirical two-zone model to estimate a range of plausible occupational exposures to health care staff. Single-source emission rates were generated in an emission chamber as a one-compartment mass balance model at steady-state. Clinical facility parameters such as room size and ventilation rate were based on standard ventilation and environmental conditions required for a laser surgical facility in compliance with regulatory agencies. All input variables in the model including point source emission rates were varied over an appropriate distribution in a Monte Carlo simulation to generate a range of time-weighted average (TWA) concentrations in the near and far field zones of the room in a conservative approach inclusive of all contributing factors to inform future predictive models. The concentrations were assessed for risk and the highest values were shown to be at least three orders of magnitude lower than the relevant occupational exposure limits (OELs). Estimated values do not appear to present a significant exposure hazard within the conditions of our emission rate estimates.
Scala, Raffaele; Nava, Stefano; Conti, Giorgio; Antonelli, Massimo; Naldi, Mario; Archinucci, Ivano; Coniglio, Giovanni; Hill, Nicholas S
2007-12-01
We recently reported a high success rate using noninvasive positive pressure ventilation (NPPV) to treat COPD exacerbations with hypercapnic encephalopathy. This study compared the hospital outcomes of NPPV vs. conventional mechanical ventilation (CMV) in COPD exacerbations with moderate to severe hypercapnic encephalopathy, defined by a Kelly score of 3 or higher. A 3-year prospective matched case-control study in a respiratory semi-intensive care unit (RSICU) and intensive care unit (ICU). From 103 consecutive patients the study included 20 undergoing NPPV and 20 CMV, matched for age, simplified acute physiology score II, and baseline arterial blood gases. ABG significantly improved in both groups after 2 h. The rate of complications was lower in the NPPV group than in the CMV group due to fewer cases of nosocomial pneumonia and sepsis. In-hospital mortality, 1-year mortality, and tracheostomy rates were similar in the two groups. Fewer patients remained on ventilation after 30 days in NPPV group. The NPPV group showed a shorter duration of ventilation. In COPD exacerbations with moderate to severe hypercapnic encephalopathy, the use of NPPV performed by an experienced team compared to CMV leads to similar short and long-term survivals with a reduced nosocomial infection rate and duration of ventilation.
Ventilation rates in recently constructed U.S. school classrooms.
Batterman, S; Su, F-C; Wald, A; Watkins, F; Godwin, C; Thun, G
2017-09-01
Low ventilation rates (VRs) in schools have been associated with absenteeism, poorer academic performance, and teacher dissatisfaction. We measured VRs in 37 recently constructed or renovated and mechanically ventilated U.S. schools, including LEED and EnergyStar-certified buildings, using CO 2 and the steady-state, build-up, decay, and transient mass balance methods. The transient mass balance method better matched conditions (specifically, changes in occupancy) and minimized biases seen in the other methods. During the school day, air change rates (ACRs) averaged 2.0±1.3 hour -1 , and only 22% of classrooms met recommended minimum ventilation rates. HVAC systems were shut off at the school day close, and ACRs dropped to 0.21±0.19 hour -1 . VRs did not differ by building type, although cost-cutting and comfort measures resulted in low VRs and potentially impaired IAQ. VRs were lower in schools that used unit ventilators or radiant heating, in smaller schools and in larger classrooms. The steady-state, build-up, and decay methods had significant limitations and biases, showing the need to confirm that these methods are appropriate. Findings highlight the need to increase VRs and to ensure that energy saving and comfort measures do not compromise ventilation and IAQ. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Carbon Dioxide Detection and Indoor Air Quality Control.
Bonino, Steve
2016-04-01
When building ventilation is reduced, energy is saved because it is not necessary to heat or cool as much outside air. Reduced ventilation can result in higher levels of carbon dioxide, which may cause building occupants to experience symptoms. Heating or cooling for ventilation air can be enhanced by a DCV system, which can save energy while providing a comfortable environment. Carbon dioxide concentrations within a building are often used to indicate whether adequate fresh air is being supplied to the building. These DCV systems use carbon dioxide sensors in each space or in the return air and adjust the ventilation based on carbon dioxide concentration; the higher the concentration, the more people occupy the space relative to the ventilation rate. With a carbon dioxide sensor DCV system, the fresh air ventilation rate varies based on the number ofpeople in the space, saving energy while maintaining a safe and comfortable environment.
Borges, Lúcia Faria; Saraiva, Mateus Sasso; Saraiva, Marcos Ariel Sasso; Macagnan, Fabrício Edler; Kessler, Adriana
2017-01-01
Objective To review the literature on the effects of expiratory rib cage compression on ventilatory mechanics, airway clearance, and oxygen and hemodynamic indices in mechanically ventilated adults. Methods Systematic review with meta-analysis of randomized clinical trials in the databases MEDLINE (via PubMed), EMBASE, Cochrane CENTRAL, PEDro, and LILACS. Studies on adult patients hospitalized in intensive care units and under mechanical ventilation that analyzed the effects of expiratory rib cage compression with respect to a control group (without expiratory rib cage compression) and evaluated the outcomes static and dynamic compliance, sputum volume, systolic blood pressure, diastolic blood pressure, mean arterial pressure, heart rate, peripheral oxygen saturation, and ratio of arterial oxygen partial pressure to fraction of inspired oxygen were included. Experimental studies with animals and those with incomplete data were excluded. Results The search strategy produced 5,816 studies, of which only three randomized crossover trials were included, totaling 93 patients. With respect to the outcome of heart rate, values were reduced in the expiratory rib cage compression group compared with the control group [-2.81 bpm (95% confidence interval [95%CI]: -4.73 to 0.89; I2: 0%)]. Regarding dynamic compliance, there was no significant difference between groups [-0.58mL/cmH2O (95%CI: -2.98 to 1.82; I2: 1%)]. Regarding the variables systolic blood pressure and diastolic blood pressure, significant differences were found after descriptive evaluation. However, there was no difference between groups regarding the variables secretion volume, static compliance, ratio of arterial oxygen partial pressure to fraction of inspired oxygen, and peripheral oxygen saturation. Conclusion There is a lack of evidence to support the use of expiratory rib cage compression in routine care, given that the literature on this topic offers low methodological quality and is inconclusive. PMID:28444078
The effect of ventilation on indoor exposure to semivolatile organic compounds.
Liu, C; Zhang, Y; Benning, J L; Little, J C
2015-06-01
A mechanistic model was developed to examine how natural ventilation influences residential indoor exposure to semivolatile organic compounds (SVOCs) via inhalation, dermal sorption, and dust ingestion. The effect of ventilation on indoor particle mass concentration and mass transfer at source/sink surfaces, and the enhancing effect of particles on mass transfer at source/sink surfaces are included. When air exchange rate increases from 0.6/h to 1.8/h, the steady-state SVOC (gas-phase plus particle phase with log KOA varying from 9 to 13) concentration in the idealized model decreases by about 60%. In contrast, for the same change in ventilation, the simulated indoor formaldehyde (representing volatile organic compounds) gas-phase concentration decreases by about 70%. The effect of ventilation on exposure via each pathway has a relatively insignificant association with the KOA of the SVOCs: a change of KOA from 10(9) to 10(13) results in a change of only 2-30%. Sensitivity analysis identifies the deposition rate of PM2.5 as a primary factor influencing the relationship between ventilation and exposure for SVOCs with log KOA = 13. The relationship between ventilation rate and air speed near surfaces needs to be further substantiated. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Volta, Carlo A; Marangoni, Elisabetta; Alvisi, Valentina; Capuzzo, Maurizia; Ragazzi, Riccardo; Pavanelli, Lina; Alvisi, Raffaele
2002-01-01
Although computerized methods of analyzing respiratory system mechanics such as the least squares fitting method have been used in various patient populations, no conclusive data are available in patients with chronic obstructive pulmonary disease (COPD), probably because they may develop expiratory flow limitation (EFL). This suggests that respiratory mechanics be determined only during inspiration. Eight-bed multidisciplinary ICU of a teaching hospital. Eight non-flow-limited postvascular surgery patients and eight flow-limited COPD patients. Patients were sedated, paralyzed for diagnostic purposes, and ventilated in volume control ventilation with constant inspiratory flow rate. Data on resistance, compliance, and dynamic intrinsic positive end-expiratory pressure (PEEPi,dyn) obtained by applying the least squares fitting method during inspiration, expiration, and the overall breathing cycle were compared with those obtained by the traditional method (constant flow, end-inspiratory occlusion method). Our results indicate that (a) the presence of EFL markedly decreases the precision of resistance and compliance values measured by the LSF method, (b) the determination of respiratory variables during inspiration allows the calculation of respiratory mechanics in flow limited COPD patients, and (c) the LSF method is able to detect the presence of PEEPi,dyn if only inspiratory data are used.
Soares, Thiago Rios; Avena, Kátia de Miranda; Olivieri, Flávia Milholo; Feijó, Luciana Ferreira; Mendes, Kristine Menezes Barberino; Souza Filho, Sydney Agareno de; Gomes, André Mansur de Carvalho Guanaes
2010-03-01
To describe the withdrawal of the bed frequency in mechanic ventilation patients and its impact on mortality and length of stay in the intensive care unit. This was a retrospective cohort study in mechanical ventilation patients. Clinical and epidemiological variables, withdrawal of bed related motor therapy, intensive care unit length of stay and mortality were evaluated. We studied 91 patients, mean age of 62.5± 18.8 years, predominantly female (52%) and mean intensive care unit length of stay of 07 days (95% CI, 8-13 days). Considering the withdrawal of the bed or not, no difference was observed between groups regarding length of stay in intensive care unit. Patients who were withdrawn of bed had a lower clinical severity. Their mortality rate was 29.7%. The not withdrawn of bed group had higher both actual and expected mortality. Patients withdrawn of bed following mechanical ventilation discontinuation showed lower mortality. It is suggested that early intensive care unit mobilization and withdrawal of bed should be stimulated.
Ventilatory Patterning in a Mouse Model of Stroke
Koo, Brian B; Strohl, Kingman P; Gillombardo, Carl B; Jacono, Frank J
2010-01-01
Cheyne-Stokes respiration (CSR) is a breathing pattern characterized by waxing and waning of breath volume and frequency, and is often recognized following stroke, when causal pathways are often obscure. We used an animal model to address the hypothesis that cerebral infarction is a mechanism for producing breathing instability. Fourteen male A/J mice underwent either stroke (n=7) or sham (n=7) procedure. Ventilation was measured using whole body plethysmography. Respiratory rate (RR), tidal volume (VT) and minute ventilation (Ve) mean values and coefficient of variation were computed for ventilation and oscillatory behavior. In addition, the ventilatory data were computationally fit to models to quantify autocorrelation, mutual information, sample entropy and a nonlinear complexity index. At the same time post procedure, stroke when compared to sham animal breathing consisted of a lower RR and autocorrelation, higher coefficient of variation for VT and higher coefficient of variation for Ve. Mutual information and the nonlinear complexity index were higher in breathing following stroke which also demonstrated a waxing/waning pattern. The absence of stroke in the sham animals was verified anatomically. We conclude that ventilatory pattern following cerebral infarction demonstrated increased variability with increased nonlinear patterning and a waxing/waning pattern, consistent with CSR. PMID:20472101
Circulatory and respiratory effects of methoxyflurane in dogs: comparison of halothane.
Steffey, E P; Farver, T B; Woliner, M J
1984-12-01
Circulatory and respiratory effects of 3 alveolar concentrations (representing 1.0, 1.5, and 2.0 times the minimal alveolar concentration, MAC) of methoxyflurane in O2 were compared with similar MAC multiples of halothane in O2. Eight adult mixed breed dogs that were healthy and nonmedicated were studied in cross-over fashion with both agents during conditions of controlled ventilation (CV; PaCO2 averaged 34 to 38 mm of Hg) and spontaneous ventilation (SV). When ventilation was controlled, methoxyflurane similar to halothane caused dose-related cardiovascular depression. Except for a greater heart rate and lesser stroke volume with methoxyflurane, little difference was noticed between the anesthetics at equivalent doses during CV. There was less dose-related circulatory depression during SV with both agents but particularly with methoxyflurane. During SV, PaCO2 increased progressively with increases in alveolar concentrations of methoxyflurane and halothane. Methoxyflurane caused significantly greater (P less than 0.05) hypoventilation than halothane only at 2.0 MAC. Except for a greater respiratory gas flow and inspiratory-expiratory gas flow ratio and a lesser inspiratory-expiratory time ratio with methoxyflurane, there was no anesthetic- or dose-response effect on respiratory variables.
The comparison of manual and LabVIEW-based fuzzy control on mechanical ventilation.
Guler, Hasan; Ata, Fikret
2014-09-01
The aim of this article is to develop a knowledge-based therapy for management of rats with respiratory distress. A mechanical ventilator was designed to achieve this aim. The designed ventilator is called an intelligent mechanical ventilator since fuzzy logic was used to control the pneumatic equipment according to the rat's status. LabVIEW software was used to control all equipments in the ventilator prototype and to monitor respiratory variables in the experiment. The designed ventilator can be controlled both manually and by fuzzy logic. Eight female Wistar-Albino rats were used to test the designed ventilator and to show the effectiveness of fuzzy control over manual control on pressure control ventilation mode. The anesthetized rats were first ventilated for 20 min manually. After that time, they were ventilated for 20 min by fuzzy logic. Student's t-test for p < 0.05 was applied to the measured minimum, maximum and mean peak inspiration pressures to analyze the obtained results. The results show that there is no statistical difference in the rat's lung parameters before and after the experiments. It can be said that the designed ventilator and developed knowledge-based therapy support artificial respiration of living things successfully. © IMechE 2014.
NASA Astrophysics Data System (ADS)
Ikhwan, M.; Hafil, A. F.; Bramanthyo, B.
2017-08-01
The Eustachian tube (ET) is responsible for the ventilation, protection, and cleaning of the middle ear. ET dysfunction plays an important role in the pathogenesis of otitis media cases, and thus the treatment and prognosis of these cases is extremely dependent on adequate ET function, which can ultimately affect the success rate of middle ear reconstruction practices. Data research on the ET’s ventilation function is needed to ensure the success of therapy and surgery treatments in the case of Chronic Suppurative Otitis Media (CSOM) patients. This study aims to investigate ET ventilation functioning in benign type CSOM and non-otitis media subjects and to develop another modality to measure ET ventilation functioning in patients with intact and perforated tympanic membranes. A comparative cross-sectional study of 36 benign type CSOM patients and 80 non-otitis media subjects will be conducted using sonotubometry and the rated parameter measurements of ET opening frequency, amplitude and ET opening duration. Malfunctioning ventilation of the ET is more common among benign type CSOM subjects (47%) than among non-otitis media subjects (18.75%). There is a significant difference (p = 0.002) between the ET ventilation functioning of benign type CSOM subjects and non-otitis media subjects—benign type CSOM subjects have rates of malfunctioning ET ventilation that are 3.88 times higher than those of non-otitis media subjects. Patients with benign type CSOM are more likely to experience malfunctioning ET ventilation than are non-otitis media subjects.
Shendell, D G; Winer, A M; Weker, R; Colome, S D
2004-06-01
The prevalence of prefabricated, portable classrooms (portables) for United States public schools has increased; in California, approximately one of three students learn inside portables. Limited research has been conducted on indoor air and environmental quality in American schools, and almost none in portables. Available reports and conference proceedings suggest problems from insufficient ventilation due to poor design, operation, and/or maintenance of heating, ventilation and air conditioning (HVAC) systems; most portables have one mechanical, wall-mounted HVAC system. A pilot assessment was conducted in Los Angeles County, including measurements of integrated ventilation rates based on a perfluorocarbon tracer gas technique and continuous monitoring of temperature (T) and relative humidity (RH). Measured ventilation rates were low [mean school day integrated average 0.8 per hour (range: 0.1-2.9 per hour)]. Compared with relevant standards, results suggested adequate ventilation and associated conditioning of indoor air for occupant comfort were not always provided to these classrooms. Future school studies should include integrated and continuous measurements of T, RH, and ventilation with appropriate tracer gas methods, and other airflow measures. Adequate ventilation has the potential to mitigate concentrations of chemical pollutants, particles, carbon dioxide, and odors in portable and traditional classrooms, which should lead to a reduction in reported health outcomes, e.g., symptoms of 'sick building syndrome', allergies, asthma. Investigations of school indoor air and environmental quality should include continuous temperature and relative humidity data with inexpensive instrumentation as indicators of thermal comfort, and techniques to measure ventilation rates.
Domingo, Christian; Blanch, Lluis; Murias, Gaston; Luján, Manel
2010-01-01
The interest in measuring physiological parameters (especially arterial blood gases) has grown progressively in parallel to the development of new technologies. Physiological parameters were first measured invasively and at discrete time points; however, it was clearly desirable to measure them continuously and non-invasively. The development of intensive care units promoted the use of ventilators via oral intubation ventilators via oral intubation and mechanical respiratory variables were progressively studied. Later, the knowledge gained in the hospital was applied to out-of-hospital management. In the present paper we review the invasive and non-invasive techniques for monitoring respiratory variables. PMID:22399898
Domingo, Christian; Blanch, Lluis; Murias, Gaston; Luján, Manel
2010-01-01
The interest in measuring physiological parameters (especially arterial blood gases) has grown progressively in parallel to the development of new technologies. Physiological parameters were first measured invasively and at discrete time points; however, it was clearly desirable to measure them continuously and non-invasively. The development of intensive care units promoted the use of ventilators via oral intubation ventilators via oral intubation and mechanical respiratory variables were progressively studied. Later, the knowledge gained in the hospital was applied to out-of-hospital management. In the present paper we review the invasive and non-invasive techniques for monitoring respiratory variables.
Horsley, Alex; Macleod, Kenneth; Gupta, Ruchi; Goddard, Nick; Bell, Nicholas
2014-01-01
Background The Innocor device contains a highly sensitive photoacoustic gas analyser that has been used to perform multiple breath washout (MBW) measurements using very low concentrations of the tracer gas SF6. Use in smaller subjects has been restricted by the requirement for a gas analyser response time of <100 ms, in order to ensure accurate estimation of lung volumes at rapid ventilation rates. Methods A series of previously reported and novel enhancements were made to the gas analyser to produce a clinically practical system with a reduced response time. An enhanced lung model system, capable of delivering highly accurate ventilation rates and volumes, was used to assess in vitro accuracy of functional residual capacity (FRC) volume calculation and the effects of flow and gas signal alignment on this. Results 10–90% rise time was reduced from 154 to 88 ms. In an adult/child lung model, accuracy of volume calculation was −0.9 to 2.9% for all measurements, including those with ventilation rate of 30/min and FRC of 0.5 L; for the un-enhanced system, accuracy deteriorated at higher ventilation rates and smaller FRC. In a separate smaller lung model (ventilation rate 60/min, FRC 250 ml, tidal volume 100 ml), mean accuracy of FRC measurement for the enhanced system was minus 0.95% (range −3.8 to 2.0%). Error sensitivity to flow and gas signal alignment was increased by ventilation rate, smaller FRC and slower analyser response time. Conclusion The Innocor analyser can be enhanced to reliably generate highly accurate FRC measurements down at volumes as low as those simulating infant lung settings. Signal alignment is a critical factor. With these enhancements, the Innocor analyser exceeds key technical component recommendations for MBW apparatus. PMID:24892522
An exposure chamber, the "clambox", was developed to measure ventilation rate, sediment processing rate, and efficiency of pollutant uptake byMacoma nasuta Conrad, a surface surface deposit-feeding clams. Clams, collected from Yaquina, Bay, Oregon, USA, were cemented into a hole ...
Mols, G; von Ungern-Sternberg, B; Rohr, E; Haberthür, C; Geiger, K; Guttmann, J
2000-06-01
To assess respiratory comfort and associated breathing pattern during volume assist (VA) as a component of proportional assist ventilation and during pressure support ventilation (PSV). Prospective, double-blind, interventional study. Laboratory. A total of 15 healthy volunteers (11 females, 4 males) aged 21-31 yrs. Decreased respiratory system compliance was simulated by banding of the thorax and abdomen. Volunteers breathed via a mouthpiece with VA and PSV each applied at two levels (VA, 8 cm H2O/L and 12 cm H2O/L; PSV, 10 cm H2O and 15 cm H2O) using a positive end-expiratory pressure of 5 cm H2O throughout. The study was subdivided into two parts. In Part 1, volunteers breathed three times with each of the four settings for 2 mins in random order. In Part 2, the first breath effects of multiple, randomly applied mode, and level shifts were studied. In Part 1, the volunteers were asked to estimate respiratory comfort in comparison with normal breathing using a visual analog scale. In Part 2, they were asked to estimate the change of respiratory comfort as increased, decreased, or unchanged immediately after a mode shift. Concomitantly, the respiratory pattern (change) was characterized with continuously measured tidal volume, respiratory rate, pressure, and gas flow. Respiratory comfort during VA was higher than during PSV. The higher support level was less important during VA but had a major negative influence on comfort during PSV. Both modes differed with respect to the associated breathing pattern. Variability of breathing was higher during VA than during PSV (Part 1). Changes in respiratory variables were associated with changes in respiratory comfort (Part 2). For volunteers breathing with artificially reduced respiratory system compliance, respiratory comfort is higher with VA than with PSV. This is probably caused by a better adaptation of the ventilatory support to the volunteer's need with VA.
Pieczkoski, Suzimara Monteiro; Margarites, Ane Glauce Freitas; Sbruzzi, Graciele
2017-01-01
Objective To verify the effectiveness of noninvasive ventilation compared to conventional physiotherapy or oxygen therapy in the mortality rate and prevention of pulmonary complications in patients during the immediate postoperative period of cardiac surgery. Methods Systematic review and meta-analysis recorded in the International Prospective Register of Ongoing Systematic Reviews (number CRD42016036441). The research included the following databases: MEDLINE, Cochrane Central, PEDro, LILACS and manual search of the references of studies published until March 2016. The review included randomized controlled trials with patients during the immediate postoperative period of cardiac surgery, which compared the use of noninvasive ventilation, BiLevel modes, continuous positive airway pressure, intermittent positive pressure breathing and positive pressure ventilation with conventional physiotherapy or oxygen therapy, and assessed the mortality rate, occurrence of pulmonary complications (atelectasis, pneumonia, acute respiratory failure, hypoxemia), reintubation rate, ventilation time, time spent in the intensive care unit (ICU), length of hospital stay and partial pressure of oxygen. Results Among the 479 selected articles, ten were included in the systematic review (n=1050 patients) and six in the meta-analysis. The use of noninvasive ventilation did not significantly reduce the risk for atelectasis (RR: 0.60; CI95% 0.28-1.28); pneumonia (RR: 0.20; CI95% 0.04-1.16), reintubation rate (RR: 0.51; CI95%: 0.15-1.66), and time spent in the ICU (-0.04 days; CI95%: -0.13; 0.05). Conclusion Prophylactic noninvasive ventilation did not significantly reduce the occurrence of pulmonary complications such as atelectasis, pneumonia, reintubation rate and time spent in the ICU. The use is still unproven and new randomized controlled trials should be carried out. PMID:28977203
Zhang, Xianming; Wu, Weiliang; Zhu, Yongcheng; Jiang, Ying; Du, Juan; Chen, Rongchang
2016-01-01
Objective It has proved that muscle paralysis was more protective for injured lung in severe acute respiratory distress syndrome (ARDS), but the precise mechanism is not clear. The purpose of this study was to test the hypothesis that abdominal muscle activity during mechanically ventilation increases lung injury in severe ARDS. Methods Eighteen male Beagles were studied under mechanical ventilation with anesthesia. Severe ARDS was induced by repetitive oleic acid infusion. After lung injury, Beagles were randomly assigned into spontaneous breathing group (BIPAPSB) and abdominal muscle paralysis group (BIPAPAP). All groups were ventilated with BIPAP model for 8h, and the high pressure titrated to reached a tidal volume of 6ml/kg, the low pressure was set at 10 cmH2O, with I:E ratio 1:1, and respiratory rate adjusted to a PaCO2 of 35–60 mmHg. Six Beagles without ventilator support comprised the control group. Respiratory variables, end-expiratory volume (EELV) and gas exchange were assessed during mechanical ventilation. The levels of Interleukin (IL)-6, IL-8 in lung tissue and plasma were measured by qRT-PCR and ELISA respectively. Lung injury scores were determined at end of the experiment. Results For the comparable ventilator setting, as compared with BIPAPSB group, the BIPAPAP group presented higher EELV (427±47 vs. 366±38 ml) and oxygenation index (293±36 vs. 226±31 mmHg), lower levels of IL-6(216.6±48.0 vs. 297.5±71.2 pg/ml) and IL-8(246.8±78.2 vs. 357.5±69.3 pg/ml) in plasma, and lower express levels of IL-6 mRNA (15.0±3.8 vs. 21.2±3.7) and IL-8 mRNA (18.9±6.8 vs. 29.5±7.9) in lung tissues. In addition, less lung histopathology injury were revealed in the BIPAPAP group (22.5±2.0 vs. 25.2±2.1). Conclusion Abdominal muscle activity during mechanically ventilation is one of the injurious factors in severe ARDS, so abdominal muscle paralysis might be an effective strategy to minimize ventilator-induce lung injury. PMID:26745868
Barotrauma and microvascular injury in lungs of nonadult rabbits: effect of ventilation pattern.
Peevy, K J; Hernandez, L A; Moise, A A; Parker, J C
1990-06-01
To study the pulmonary microvascular injury produced by ventilation barotrauma, the isolated perfused lungs of 4 to 6-wk-old New Zealand white rabbits were ventilated by one of the following methods: peak inspiratory pressure (PIP) 23 cm H2O, gas flow rate 1.1 L/min (group 1); PIP 27 cm H2O, gas flow rate 6.9 L/min (group 2); PIP 50 cm H2O, gas flow rate 1.9 L/min (group 3); or PIP 53 cm H2O, gas flow rate 8.3 L/min (group 4). Microvascular permeability was assessed using the capillary filtration coefficient (Kfc) before and 5, 30, and 60 min after a 15-min period of ventilation. Baseline Kfc was not significantly different between groups. A significant increase over the baseline Kfc was noted at 60 min in group 2 and in all postventilation Kfc values in groups 3 and 4 (p less than .05). Group 1 Kfc values did not change significantly after ventilation. At all post-ventilation times, values for Kfc were significantly greater in groups 3 and 4 than in group 1 (p less than .05). Group 4 Kfc values were significantly greater than those in group 2 at 5 and 30 min postventilation. These data indicate that high PIP, and to a lesser extent, high gas flow rates cause microvascular injury in the compliant nonadult lung and suggest that the combination of high PIP and high gas flow rates are the most threatening to microvascular integrity.
Singer, Brett C; Hodgson, Alfred T; Guevarra, Karla S; Hawley, Elisabeth L; Nazaroff, William W
2002-03-01
We measured the emissions of 26 gas-phase organic compounds in environmental tobacco smoke (ETS) using a model room that simulates realistic conditions in residences and offices. Exposure-relevant emission factors (EREFs), which include the effects of sorption and re-emission over a 24-h period, were calculated by mass balance from measured compound concentrations and chamber ventilation rates in a 50-m3 room constructed and furnished with typical materials. Experiments were conducted at three smoking rates (5, 10, and 20 cigarettes day(-1)), three ventilation rates (0.3, 0.6, and 2 h(-1)), and three furnishing levels (wallboard with aluminum flooring, wallboard with carpet, and full furnishings). Smoking rate did not affect EREFs, suggesting that sorption was linearly related to gas-phase concentration. Furnishing level and ventilation rate in the model room had little effect on EREFs of several ETS compounds including 1,3-butadiene, acrolein, acrylonitrile, benzene, toluene, and styrene. However, sorptive losses at low ventilation with full furnishings reduced EREFs for the ETS tracers nicotine and 3-ethenylpyridine by as much as 90 and 65% as compared to high ventilation, wallboard/aluminum experiments. Likewise, sorptive losses were 40-70% for phenol, cresols, naphthalene, and methylnaphthalenes. Sorption persisted for many compounds; for example, almost all of the sorbed nicotine and most of the sorbed cresol remained sorbed 3 days after smoking. EREFs can be used in models and with ETS tracer-based methods to refine and improve estimates of exposures to ETS constituents.
DOE Office of Scientific and Technical Information (OSTI.GOV)
?Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, andmore » filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy.« less
Sinuff, Tasnim; Muscedere, John; Cook, Deborah J; Dodek, Peter M; Anderson, William; Keenan, Sean P; Wood, Gordon; Tan, Richard; Haupt, Marilyn T; Miletin, Michael; Bouali, Redouane; Jiang, Xuran; Day, Andrew G; Overvelde, Janet; Heyland, Daren K
2013-01-01
Ventilator-associated pneumonia is an important cause of morbidity and mortality in critically ill patients. Evidence-based clinical practice guidelines for the prevention, diagnosis, and treatment of ventilator-associated pneumonia may improve outcomes, but optimal methods to ensure implementation of guidelines in the intensive care unit are unclear. Hence, we determined the effect of educational sessions augmented with reminders, and led by local opinion leaders, as strategies to implement evidence-based ventilator-associated pneumonia guidelines on guideline concordance and ventilator-associated pneumonia rates. Two-year prospective, multicenter, time-series study conducted between June 2007 and December 2009. Eleven ICUs (ten in Canada, one in the United States); five academic and six community ICUs. At each site, 30 adult patients mechanically ventilated >48 hrs were enrolled during four data collection periods (baseline, 6, 15, and 24 months). Guideline recommendations for the prevention, diagnosis, and treatment of ventilator-associated pneumonia were implemented using a multifaceted intervention (education, reminders, local opinion leaders, and implementation teams) directed toward the entire multidisciplinary ICU team. Clinician exposure to the intervention was assessed at 6, 15, and 24 months after the introduction of this intervention. The main outcome measure was aggregate concordance with the 14 ventilator-associated pneumonia guideline recommendations. One thousand three hundred twenty patients were enrolled (330 in each study period). Clinician exposure to the multifaceted intervention was high and increased during the study: 86.7%, 93.3%, 95.8%, (p < .001), as did aggregate concordance (mean [SD]): 50.7% (6.1), 54.4% (7.1), 56.2% (5.9), 58.7% (6.7) (p = .007). Over the study period, ventilator-associated pneumonia rates decreased (events/330 patients): 47 (14.2%), 34 (10.3%), 38 (11.5%), 29 (8.8%) (p = .03). A 2-yr multifaceted intervention to enhance ventilator-associated pneumonia guideline uptake was associated with a significant increase in guideline concordance and a reduction in ventilator-associated pneumonia rates.
Nilius, Georg; Katamadze, Nato; Domanski, Ulrike; Schroeder, Maik; Franke, Karl-Josef
2017-01-01
COPD patients who develop chronic hypercapnic respiratory failure have a poor prognosis. Treatment of choice, especially the best form of ventilation, is not well known. This study compared the effects of pressure-controlled (spontaneous timed [ST]) non-invasive ventilation (NIV) and NIV with intelligent volume-assured pressure support (IVAPS) in chronic hypercapnic COPD patients regarding the effects on alveolar ventilation, adverse patient/ventilator interactions and sleep quality. This prospective, single-center, crossover study randomized patients to one night of NIV using ST then one night with the IVAPS function activated, or vice versa. Patients were monitored using polysomnography (PSG) and transcutaneous carbon dioxide pressure (PtcCO 2 ) measurement. Patients rated their subjective experience (total score, 0-45; lower scores indicate better acceptability). Fourteen patients were included (4 females, age 59.4±8.9 years). The total number of respiratory events was low, and similar under pressure-controlled (5.4±6.7) and IVAPS (8.3±10.2) conditions ( P =0.064). There were also no clinically relevant differences in PtcCO 2 between pressure-controlled and IVAPS NIV (52.9±6.2 versus 49.1±6.4 mmHg). Respiratory rate was lower under IVAPS overall; between-group differences reached statistical significance during wakefulness and non-rapid eye movement sleep. Ventilation pressures were 2.6 cmH 2 O higher under IVAPS versus pressure-controlled ventilation, resulting in a 20.1 mL increase in breathing volume. Sleep efficiency was slightly higher under pressure-controlled ventilation versus IVAPS. Respiratory arousals were uncommon (24.4/h [pressure-controlled] versus 25.4/h [IVAPS]). Overall patient assessment scores were similar, although there was a trend toward less discomfort during IVAPS. Our results show that IVAPS NIV allows application of higher nocturnal ventilation pressures versus ST without affecting sleep quality or inducing ventilation- associated events.
NASA Astrophysics Data System (ADS)
Visbeck, M.; Banyte, D.; Brandt, P.; Dengler, M.; Fischer, T.; Karstensen, J.; Krahmann, G.; Tanhua, T. S.; Stramma, L.
2013-12-01
Equatorial Dynamics provide an essential influence on the ventilation pathways of well oxygenated surface water on their route to tropical oxygen minimum zones (OMZ). The large scale wind driven circulation shield OMZs from the direct ventilation pathways. They are located in the so called ';shadow zones' equator ward of the subtropical gyres. From what is known most of the oxygen is supplied via pathways from the western boundary modulated by the complex zonal equatorial current system and marginally by vertical mixing. What was less clear is which of the possible pathways are most effective in transporting dissolved oxygen towards the OMZ. A collaborative research program focused on the dynamics of oxygen minimum zones, called SFB754 "Climate - Biogeochemistry Interactions in the Tropical Ocean", allowed us to conduct two ocean tracer release experiments to investigate the vertical and horizontal mixing rates and associated oxygen transports. Specifically we report on the first deliberate tracer release experiment (GUTRE, Guinea Upwelling Tracer Release Experiment) in the tropical northeast Atlantic carried out in order to determine the diapycnal diffusivity coefficient in the upper layer of the OMZ. A tracer (CF3SF5) was injected in spring of 2008 and subsequently measured during three designated tracer survey cruises until the end of 2010. We found that, generally, the diffusivity is larger than expected for low latitudes and similar in magnitude to what has previously been experimentally determined in the Canary Basin. When combining the tracer study with estimates of diapycnal mixing based on microstructure profiling and a newly developed method using ship board ADCPs we were able to compute the vertical oxygen flux and its divergence for the OMZ. To our surprise, the vertical flux of oxygen by diapycnal mixing provides about 30% of the total ventilation. The estimate was derived from the simple advection-diffusion model taking into account moored and ship based velocity observations of the equatorial current systems along 23°W in the tropical Atlantic. However, the advective pathways are less certain and possibly more variable. Firstly, the strength of lateral eddy stirring and the role in oxygen transport is less well known, and is the focus of the ongoing second tracer release experiment (OSTRE, Oxygen Supply Tracer Release Experiment). Secondly, the analysis of historical data from the equatorial regime suggests that the observed decline in dissolved oxygen in the tropical North Atlantic might in part be a consequence of reduced horizontal ventilation by equatorial intermediate current systems. The uncertainty of the long-term variability of the circulation in the equatorial systems and additional uncertainty in the biogeochemical consumption rates provide a challenge for estimates of the future of the OMZ regimes. Model prediction of future oxygen changes depend on the models ability to reproduce the observed oxygen ventilation pathways and processes, which might limit the prediction's accuracy.
VENTILATION RESEARCH: A REVIEW OF RECENT INDOOR AIR QUALITY LITERATURE
The report gives results of a literature review, conducted to survey and summarize recent and ongoing engineering research into building ventilation, air exchange rate, pollutant distribution and dispersion, and other effects of heating, ventilation, and air-conditioning (HVAC) s...
Mousavi, Ehsan S; Grosskopf, Kevin R
2015-11-01
Most studies on the transmission of infectious airborne disease have focused on patient room air changes per hour (ACH) and how ACH provides pathogen dilution and removal. The logical but mostly unproven premise is that greater air change rates reduce the concentration of infectious particles and thus, the probability of airborne disease transmission. Recently, a growing body of research suggests pathways between pathogenic source (patient) and control (exhaust) may be the dominant environmental factor. While increases in airborne disease transmission have been associated with ventilation rates below 2 ACH, comparatively less data are available to quantify the benefits of higher air change rates in clinical spaces. As a result, a series of tests were conducted in an actual hospital to observe the containment and removal of respirable aerosols (0.5-10 µm) with respect to ventilation rate and directional airflow in a general patient room, and, an airborne infectious isolation room. Higher ventilation rates were not found to be proportionately effective in reducing aerosol concentrations. Specifically, increasing mechanical ventilation from 2.5 to 5.5 ACH reduced aerosol concentrations only 30% on average. However, particle concentrations were more than 40% higher in pathways between the source and exhaust as was the suspension and migration of larger particles (3-10 µm) throughout the patient room(s). Computational analyses were used to validate the experimental results, and, to further quantify the effect of ventilation rate on exhaust and deposition removal in patient rooms as well as other particle transport phenomena. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Infiltration as Ventilation: Weather-Induced Dilution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherman, Max H.; Turner, William J.N.; Walker, Iain S.
The purpose of outdoor air ventilation is to dilute or remove indoor contaminants to which occupants are exposed. It can be provided by mechanical or natural means. In most homes, especially older homes, weather-driven infiltration provides the dominant fraction of the total ventilation. As we seek to provide good indoor air quality at minimum energy cost, it is important to neither over-ventilate nor under-ventilate. Thus, it becomes critically important to evaluate correctly the contribution infiltration makes to the total outdoor air ventilation rate. Because weather-driven infiltration is dependent on building air leakage and weather-induced pressure differences, a given amount ofmore » air leakage will provide different amounts of infiltration. Varying rates of infiltration will provide different levels of contaminant dilution and hence effective ventilation. This paper derives these interactions and then calculates the impact of weather-driven infiltration for different climates. A new “N-factor” is introduced to provide a convenient method for calculating the ventilation contribution of infiltration for over 1,000 locations across North America. The results of this work could be used in indoor air quality standards (specifically ASHRAE 62.2) to account for the contribution of weather-driven infiltration towards the dilution of indoor pollutants.« less
New modes of assisted mechanical ventilation.
Suarez-Sipmann, F
2014-05-01
Recent major advances in mechanical ventilation have resulted in new exciting modes of assisted ventilation. Compared to traditional ventilation modes such as assisted-controlled ventilation or pressure support ventilation, these new modes offer a number of physiological advantages derived from the improved patient control over the ventilator. By implementing advanced closed-loop control systems and using information on lung mechanics, respiratory muscle function and respiratory drive, these modes are specifically designed to improve patient-ventilator synchrony and reduce the work of breathing. Depending on their specific operational characteristics, these modes can assist spontaneous breathing efforts synchronically in time and magnitude, adapt to changing patient demands, implement automated weaning protocols, and introduce a more physiological variability in the breathing pattern. Clinicians have now the possibility to individualize and optimize ventilatory assistance during the complex transition from fully controlled to spontaneous assisted ventilation. The growing evidence of the physiological and clinical benefits of these new modes is favoring their progressive introduction into clinical practice. Future clinical trials should improve our understanding of these modes and help determine whether the claimed benefits result in better outcomes. Copyright © 2013 Elsevier España, S.L. and SEMICYUC. All rights reserved.
López López, C; Murillo Pérez, M A; Torrente Vela, S; Cornejo Bauer, C; García Iglesias, M; Orejana Martín, M; Morales Sánchez, C; Cuenca Solanas, M; Alted López, E
2013-01-01
To assess pain in non-communicative patients with severe trauma undergoing mechanical ventilation prior to, during and after tracheal suctioning, mobilization and wound care. A prospective and observational study from October to December 2011 was performed. Study variables were ESCID scale and monitoring of vital signs (blood pressure, heart rate, and respiratory rate). Data were gathering 5 minutes before, during and 15 minutes after the 3 procedures. The nursing evolutive report recorded pain assessment, administration and effectiveness of the analgesia. Descriptive analysis of variables included Student's T test/ANOVA for multivariate analysis with SPSS 17.0. A hundred eighty four observations: 46.8% tracheal suctioning, 38.5% mobilization and 14.7% wound care were performed in 29 patients. ESCID score was 0.4±1 before, 3.4±2.7 during and 0.4±1 after for wound care; 0.4±1.1 before, 3.6±2.2 during and 1.1±0.5 for tracheal suctioning; 0.5±1.1 before, 3±2.8 during and 0.2±0.8 after for mobilization. These increased significantly during the performance of the 3 procedures before-during/during-after: P=.000. All the hemodynamic variables were significantly modified during mobilization and tracheal suctioning: before-during/during-after: P=.000, with the exception of the cures that only affected respiratory rate. 27% of the procedures received analgesia: 9% received it before, 15% during and 3.2% after, with more analgesia being required for the wound care (33.3%). The data collected in the nursing report on the evaluation of pain/effectiveness of the analgesia showed 20.66%. An increase on the ESCID score was observed while performing the procedures. Copyright © 2013 Elsevier España, S.L. y SEEIUC. All rights reserved.
Alberton, C L; Kanitz, A C; Pinto, S S; Antunes, A H; Finatto, P; Cadore, E L; Kruel, L F M
2013-08-01
The aim of this study was to compare the cardiorespiratory variables corresponding to the anaerobic threshold (AT) between different water-based exercises using two methods of determining the AT, the heart rate deflection point and ventilatory method, and to correlate the variables in both methods. Twenty young women performed three exercise sessions in the water. Maximal tests were performed in the water-based exercises stationary running, frontal kick and cross country skiing. The protocol started at a rate of 80 cycles per minute (cycle.min-1) for 2 min with subsequent increments of 10 cycle.min-1 every minute until exhaustion, with measurements of heart rate, oxygen uptake and ventilation throughout test. After, the two methods were used to determine the values of these variables corresponding to the AT for each of the exercises. Comparisons were made using two-way ANOVA for repeated measures with Bonferroni's post hoc test. To correlate the same variables determined by the two methods, the intra-class correlation coefficient test (ICC) was used. For all the variables, no significant differences were found between the methods of determining the AT and the three exercises. Moreover, the ICC values of each variable determined by the two methods were high and significant. The estimation of the heart rate deflection point can be used as a simple and practical method of determining the AT, which can be used when prescribing these exercises. In addition, these cardiorespiratory parameters may be determined performing the test with only one of the evaluated exercises, since there were no differences in the evaluated variables.
Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto
2014-01-01
Objective: Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. Methods: This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Results: Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. Conclusions: The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM. PMID:25029653
The influence of opening windows and doors on the natural ventilation rate of a residential building
An analysis of air exchange rates due to intentional window and door openings in a research test house located in a residential environment is presented. These data inform the development of ventilation rate control strategies as building envelopes are tightened to improve the e...
2005-10-25
Chest compression , Ventilation 2P251107 256Page 2 1. Introduction During the initial stages of cardiopulmonary resuscitation ( CPR ), ventilation is...a metronome to facilitate chest compression timing. Twenty-eight nurses alternated performing 4 minutes of CPR using the BVM or Impact 730 to deliver... Chest compression and ventilation rates during cardiopulmonary resuscitation : the effects of audible tone guidance. Academic Emergency Medicine
Occupant perception of indoor air and comfort in four hospitality environments.
Moschandreas, D J; Chu, P
2002-01-01
This article reports on a survey of customer and staff perceptions of indoor air quality at two restaurants, a billiard hall, and a casino. The survey was conducted at each environment for 8 days: 2 weekend days on 2 consecutive weekends and 4 weekdays. Before and during the survey, each hospitality environment satisfied ventilation requirements set in ASHRAE Standard 62-1999, Ventilation for Acceptable Indoor Air. An objective of this study was to test the hypothesis: If a hospitality environment satisfies ASHRAE ventilation requirements, then the indoor air is acceptable, that is, fewer than 20% of the exposed occupants perceive the environment as unacceptable. A second objective was to develop a multiple regression model that predicts the dependent variable, the environment is acceptable, as a function of a number of independent perception variables. Occupant perception of environmental, comfort, and physical variables was measured using a questionnaire. This instrument was designed to be efficient and unobtrusive; subjects could complete it within 3 min. Significant differences of occupant environment perception were identified among customers and staff. The dependent variable, the environment is acceptable, is affected by temperature, occupant density, and occupant smoking status, odor perception, health conditions, sensitivity to chemicals, and enjoyment of activities. Depending on the hospitality environment, variation of independent variables explains as much as 77% of the variation of the dependent variable.
Communication of mechanically ventilated patients in intensive care units
Martinho, Carina Isabel Ferreira; Rodrigues, Inês Tello Rato Milheiras
2016-01-01
Objective The aim of this study was to translate and culturally and linguistically adapt the Ease of Communication Scale and to assess the level of communication difficulties for patients undergoing mechanical ventilation with orotracheal intubation, relating these difficulties to clinical and sociodemographic variables. Methods This study had three stages: (1) cultural and linguistic adaptation of the Ease of Communication Scale; (2) preliminary assessment of its psychometric properties; and (3) observational, descriptive-correlational and cross-sectional study, conducted from March to August 2015, based on the Ease of Communication Scale - after extubation answers and clinical and sociodemographic variables of 31 adult patients who were extubated, clinically stable and admitted to five Portuguese intensive care units. Results Expert analysis showed high agreement on content (100%) and relevance (75%). The pretest scores showed a high acceptability regarding the completion of the instrument and its usefulness. The Ease of Communication Scale showed excellent internal consistency (0.951 Cronbach's alpha). The factor analysis explained approximately 81% of the total variance with two scale components. On average, the patients considered the communication experiences during intubation to be "quite hard" (2.99). No significant correlation was observed between the communication difficulties reported and the studied sociodemographic and clinical variables, except for the clinical variable "number of hours after extubation" (p < 0.05). Conclusion This study translated and adapted the first assessment instrument of communication difficulties for mechanically ventilated patients in intensive care units into European Portuguese. The preliminary scale validation suggested high reliability. Patients undergoing mechanical ventilation reported that communication during intubation was "quite hard", and these communication difficulties apparently existed regardless of the presence of other clinical and/or sociodemographic variables. PMID:27410408
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hult, Erin L.; Willem, Henry; Price, Phillip N.
2014-10-01
Measurements were taken in new US residences to assess the extent to which ventilation and source control can mitigate formaldehyde exposure. Increasing ventilation consistently lowered indoor formaldehyde concentrations. However, at a reference air exchange rate of 0.35 h -1, increasing ventilation was up to 60% less effective than would be predicted if the emission rate were constant. This is consistent with formaldehyde emission rates decreasing as air concentrations increase, as observed in chamber studies. In contrast, measurements suggest acetaldehyde emission was independent of ventilation rate. To evaluate the effectiveness of source control, formaldehyde concentrations were measured in Leadership in Energymore » and Environmental Design (LEED) certified/Indoor airPLUS homes constructed with materials certified to have low emission rates of volatile organic compounds (VOC). At a reference air exchange rate of 0.35 h -1, and adjusting for home age, temperature and relative humidity, formaldehyde concentrations in homes built with low-VOC materials were 42% lower on average than in reference new homes with conventional building materials. Without adjustment, concentrations were 27% lower in the low-VOC homes. The mean and standard deviation of formaldehyde concentration were 33 μg m-3 and 22 μg m -3 for low-VOC homes and 45 μg m -3 and 30 μg m -3 for conventional.« less
Oxygen consumption of a pneumatically controlled ventilator in a field anesthesia machine.
Szpisjak, Dale F; Javernick, Elizabeth N; Kyle, Richard R; Austin, Paul N
2008-12-01
Field anesthesia machines (FAM) have been developed for remote locations where reliable supplies of compressed medical gases or electricity may be absent. In place of electricity, pneumatically controlled ventilators use compressed gas to power timing circuitry and actuate valves. We sought to determine the total O(2) consumption and ventilator gas consumption (drive gas [DG] plus pneumatic control [PC] gas) of a FAM's pneumatically controlled ventilator in mechanical models of high (HC) and low (LC) total thoracic compliance. The amount of total O(2) consumed by the Magellan-2200 (Oceanic Medical Products, Atchison, KS) FAM with pneumatically controlled ventilator was calculated using the ideal gas law and the measured mass of O(2) consumed from E cylinders. DG to the bellows canister assembly was measured with the Wright Respirometer Mk 8 (Ferraris Respiratory Europe, Hertford, UK). PC gas consumption was calculated by subtracting DG and fresh gas flow (FGF) from the total O(2) consumed from the E cylinder. The delivered tidal volume (V(T)) was measured with a pneumotach (Hans Rudolph, KS City, MO). Three different V(T) were tested (500, 750, and 1000 mL) with two lung models (HC and LC) using the Vent Aid Training Test Lung (MI Instruments, Grand Rapids, MI). Respiratory variables included an I:E of 1:2, FGF of 1 L/min, and respiratory rate of 10 breaths/min. Total O(2) consumption was directly proportional to V(T) and inversely proportional to compliance. The smallest total O(2) consumption rate (including FGF) was 9.3 +/- 0.4 L/min in the HC-500 model and the largest was 15.9 +/- 0.5 L/min in the LC-1000 model (P < 0.001). The mean PC circuitry consumption was 3.9 +/- 0.24 L/min or 390 mL +/- 24 mL/breath. To prepare for loss of central DG supply, patient safety will be improved by estimating cylinder duration for low total thoracic compliance. Using data from the smaller compliance and greatest V(T) model (LC-1000), a full O(2) E cylinder would be depleted in <42 min, whereas a full H cylinder would last approximately 433 min.
Türk, Murat; Aydoğdu, Müge; Gürsel, Gül
2018-01-01
Different outcomes and success rates of non-invasive positive pressure ventilation (NPPV) in patients with acute hypercapnic respiratory failure (AHRF) still pose a significant problem in intensive care units. Previous studies investigating different modes, body positioning, and obesity-associated hypoventilation in patients with chronic respiratory failure showed that these factors may affect ventilator mechanics to achieve a better minute ventilation. This study tried to compare pressure support (BiPAP-S) and average volume targeted pressure support (AVAPS-S) modes in patients with acute or acute-on-chronic hypercapnic respiratory failure. In addition, short-term effects of body position and obesity within both modes were analyzed. We conducted a randomized controlled study in a 7-bed intensive care unit. The course of blood gas analysis and differences in ventilation variables were compared between BiPAP-S (n=33) and AVAPS-S (n=29), and between semi-recumbent and lateral positions in both modes. No difference was found in the length of hospital stay and the course of PaCO2, pH, and HCO3 levels between the modes. There was a mean reduction of 5.7±4.1 mmHg in the PaCO2 levels in the AVAPS-S mode, and 2.7±2.3 mmHg in the BiPAP-S mode per session (p<0.05). Obesity didn't have any effect on the course of PaCO2 in both the modes. Body positioning had no notable effect in both modes. Although the decrease in the PaCO2 levels in the AVAPS-S mode per session was remarkably high, the course was similar in both modes. Furthermore, obesity and body positioning had no prominent effect on the PaCO2 response and ventilator mechanics. Post hoc power analysis showed that the sample size was not adequate to detect a significant difference between the modes.
Emissions of particulate matter from animal houses in the Netherlands
NASA Astrophysics Data System (ADS)
Winkel, Albert; Mosquera, Julio; Groot Koerkamp, Peter W. G.; Ogink, Nico W. M.; Aarnink, André J. A.
2015-06-01
In the Netherlands, emissions from animal houses represent a major source of ambient particulate matter (PM). The objective of the present paper was to provide accurate and up to date concentrations and emission rates of PM10 and PM2.5 for commonly used animal housing systems, under representative inside and outside climate conditions and ventilation rates. We set up a national survey which covered 13 housing systems for poultry, pigs, and dairy cattle, and included 36 farms. In total, 202 24-h measurements were carried out, which included concentrations of inhalable PM, PM10, PM2.5, and CO2, ventilation rate, temperature, and relative humidity. On an animal basis, geometric mean emission rates of PM10 ranged from 2.2 to 12.0 mg h-1 in poultry and from 7.3 to 22.5 mg h-1 in pigs. The mean PM10 emission rate in dairy cattle was 8.5 mg h-1. Geometric mean emission rates of PM2.5 ranged from 0.11 to 2.41 mg h-1 in poultry and from 0.21 to 1.56 mg h-1 in pigs. The mean PM2.5 emission rate in dairy cattle was 1.65 mg h-1. Emissions are also reported per Livestock Unit and Heat Production Unit. PM emission rates increased exponentially with increasing age in broilers and turkeys and increased linearly with increasing age in weaners and fatteners. In laying hens, broiler breeders, sows, and dairy cattle, emission levels were variable throughout the year.
Significant Improvements in Pyranometer Nighttime Offsets Using High-Flow DC Ventilation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kutchenreiter, Mark; Michalski, J.J.; Long, C.N.
2017-05-22
Accurate solar radiation measurements using pyranometers are required to understand radiative impacts on the Earth's energy budget, solar energy production, and to validate radiative transfer models. Ventilators of pyranometers, which are used to keep the domes clean and dry, also affect instrument thermal offset accuracy. This poster presents a high-level overview of the ventilators for single-black-detector pyranometers and black-and-white pyranometers. For single-black-detector pyranometers with ventilators, high-flow-rate (50-CFM and higher), 12-V DC fans lower the offsets, lower the scatter, and improve the predictability of nighttime offsets compared to lower-flow-rate (35-CFM), 120-V AC fans operated in the same type of environmental setup.more » Black-and-white pyranometers, which are used to measure diffuse horizontal irradiance, sometimes show minor improvement with DC fan ventilation, but their offsets are always small, usually no more than 1 W/m2, whether AC- or DC-ventilated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scofield, C.M.; Des Champs, N.H.
This article examines a design concept for classroom air conditioning systems that guarantees minimum ventilation rates are met. The topics of the article include new ventilation requirements, design concept, outside air induction diffuser, low-velocity ducts and plenums, the relationship of humidity to school absenteeism rates, retrofit applications, and saving energy.
Quantitative relationship of sick building syndrome symptoms with ventilation rates
Data from published studies were combined and analyzed to develop best-fit equations and curves quantifying the change in sick building syndrome (SBS) symptom prevalence in office workers with ventilation rate. For each study, slopes were calculated, representing the fractional...
Leturiondo, Mikel; Ruiz de Gauna, Sofía; Ruiz, Jesus M; Julio Gutiérrez, J; Leturiondo, Luis A; González-Otero, Digna M; Russell, James K; Zive, Dana; Daya, Mohamud
2018-03-01
Capnography has been proposed as a method for monitoring the ventilation rate during cardiopulmonary resuscitation (CPR). A high incidence (above 70%) of capnograms distorted by chest compression induced oscillations has been previously reported in out-of-hospital (OOH) CPR. The aim of the study was to better characterize the chest compression artefact and to evaluate its influence on the performance of a capnogram-based ventilation detector during OOH CPR. Data from the MRx monitor-defibrillator were extracted from OOH cardiac arrest episodes. For each episode, presence of chest compression artefact was annotated in the capnogram. Concurrent compression depth and transthoracic impedance signals were used to identify chest compressions and to annotate ventilations, respectively. We designed a capnogram-based ventilation detection algorithm and tested its performance with clean and distorted episodes. Data were collected from 232 episodes comprising 52 654 ventilations, with a mean (±SD) of 227 (±118) per episode. Overall, 42% of the capnograms were distorted. Presence of chest compression artefact degraded algorithm performance in terms of ventilation detection, estimation of ventilation rate, and the ability to detect hyperventilation. Capnogram-based ventilation detection during CPR using our algorithm was compromised by the presence of chest compression artefact. In particular, artefact spanning from the plateau to the baseline strongly degraded ventilation detection, and caused a high number of false hyperventilation alarms. Further research is needed to reduce the impact of chest compression artefact on capnographic ventilation monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.
Ventilation System Effectiveness and Tested Indoor Air Quality Impacts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rudd, Armin; Bergey, Daniel
In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the sourcemore » of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.« less
Ventilation System Effectiveness and Tested Indoor Air Quality Impacts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rudd, Armin; Bergey, Daniel
Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, themore » ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.« less
Scheer, Krista S; Siebrant, Sarah M; Brown, Gregory A; Shaw, Brandon S; Shaw, Ina
Nintendo Wii, Sony Playstation Move , and Microsoft XBOX Kinect are home video gaming systems that involve player movement to control on-screen game play. Numerous investigations have demonstrated that playing Wii is moderate physical activity at best, but Move and Kinect have not been as thoroughly investigated. The purpose of this study was to compare heart rate, oxygen consumption, and ventilation while playing the games Wii Boxing, Kinect Boxing, and Move Gladiatorial Combat. Heart rate, oxygen consumption, and ventilation were measured at rest and during a graded exercise test in 10 males and 9 females (19.8 ± 0.33 y, 175.4 ± 2.0 cm, 80.2 ± 7.7 kg,). On another day, in a randomized order, the participants played Wii Boxing, K inect Boxing, and Move Gladiatorial Combat while heart rate, ventilation, and oxygen consumption were measured. There were no differences in heart rate (116.0 ± 18.3 vs. 119.3 ± 17.6 vs. 120.1 ± 17.6 beats/min), oxygen consumption (9.2 ± 3.0 vs. 10.6 ± 2.4 vs. 9.6 ± 2.4 ml/kg/min), or minute ventilation (18.9 ± 5.7 vs. 20.8 ± 8.0 vs. 19.7 ± 6.4 L/min) when playing Wii boxing, Kinect boxing, or Move Gladiatorial Combat (respectively). Playing Nintendo Wii Boxing, XBOX Kinect Boxing, and Sony PlayStation Move Gladiatorial Combat all increase heart rate, oxygen consumption, and ventilation above resting levels but there were no significant differences between gaming systems. Overall, playing a "physically active" home video game system does not meet the minimal threshold for moderate intensity physical activity, regardless of gaming system.
SCHEER, KRISTA S.; SIEBRANT, SARAH M.; BROWN, GREGORY A.; SHAW, BRANDON S.; SHAW, INA
2014-01-01
Nintendo Wii, Sony Playstation Move, and Microsoft XBOX Kinect are home video gaming systems that involve player movement to control on-screen game play. Numerous investigations have demonstrated that playing Wii is moderate physical activity at best, but Move and Kinect have not been as thoroughly investigated. The purpose of this study was to compare heart rate, oxygen consumption, and ventilation while playing the games Wii Boxing, Kinect Boxing, and Move Gladiatorial Combat. Heart rate, oxygen consumption, and ventilation were measured at rest and during a graded exercise test in 10 males and 9 females (19.8 ± 0.33 y, 175.4 ± 2.0 cm, 80.2 ± 7.7 kg,). On another day, in a randomized order, the participants played Wii Boxing, Kinect Boxing, and Move Gladiatorial Combat while heart rate, ventilation, and oxygen consumption were measured. There were no differences in heart rate (116.0 ± 18.3 vs. 119.3 ± 17.6 vs. 120.1 ± 17.6 beats/min), oxygen consumption (9.2 ± 3.0 vs. 10.6 ± 2.4 vs. 9.6 ± 2.4 ml/kg/min), or minute ventilation (18.9 ± 5.7 vs. 20.8 ± 8.0 vs. 19.7 ± 6.4 L/min) when playing Wii boxing, Kinect boxing, or Move Gladiatorial Combat (respectively). Playing Nintendo Wii Boxing, XBOX Kinect Boxing, and Sony PlayStation Move Gladiatorial Combat all increase heart rate, oxygen consumption, and ventilation above resting levels but there were no significant differences between gaming systems. Overall, playing a “physically active” home video game system does not meet the minimal threshold for moderate intensity physical activity, regardless of gaming system. PMID:27182399
Dunster, Kimble R; Davies, Mark W; Fraser, John F
2006-01-01
Background The loss of perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be minimized both to prevent perfluorocarbon vapour entering the atmosphere and to re-use the recovered PFC liquid. Using a substantially modified design of our previously described condenser, we aimed to determine how much perfluorocarbon liquid could be recovered from gases containing PFC and water vapour, at concentrations found during partial liquid ventilation, and to determine if the amount recovered differed with background flow rate (at flow rates suitable for use in neonates). Methods The expiratory line of a standard ventilator circuit set-up was mimicked, with the addition of two condensers. Perfluorocarbon (30 mL of FC-77) and water vapour, at concentrations found during partial liquid ventilation, were passed through the circuit at a number of flow rates and the percentage recovery of the liquids measured. Results From 14.2 mL (47%) to 27.3 mL (91%) of the infused 30 mL of FC-77 was recovered at the flow rates studied. Significantly higher FC-77 recovery was obtained at lower flow rates (ANOVA with Bonferroni's multiple comparison test, p < 0.0001). As a percentage of the theoretical maximum recovery, 64 to 95% of the FC-77 was recovered. Statistically significantly less FC-77 was recovered at 5 Lmin-1 (ANOVA with Bonferroni's multiple comparison test, p < 0.0001). Amounts of perfluorocarbon vapour recovered were 47%, 50%, 81% and 91% at flow rates of 10, 5, 2 and 1 Lmin-1, respectively. Conclusion Using two condensers in series 47% to 91% of perfluorocarbon liquid can be recovered, from gases containing perfluorocarbon and water vapour, at concentrations found during partial liquid ventilation. PMID:16457722
Ventilation through a small-bore catheter: optimizing expiratory ventilation assistance.
Hamaekers, A E W; Borg, P A J; Götz, T; Enk, D
2011-03-01
Emergency ventilation through a small-bore transtracheal catheter can be lifesaving in a 'cannot intubate, cannot ventilate' situation. Ejectors, capable of creating suction by the Bernoulli principle, have been proposed to facilitate expiration through small-bore catheters. In this bench study, we compared a novel, purpose-built ventilation ejector (DE 5) with a previously proposed, modified industrial ejector (SBP 07). The generated insufflation pressures, suction pressures in static and dynamic situations, and also suction capacities and entrainment ratios of the SBP 07 and the DE 5 were determined. The DE 5 was also tested in a lung simulator with a simulated complete upper airway obstruction. Inspiratory and expiratory times through a transtracheal catheter were measured at various flow rates and achievable minute volumes were calculated. In a static situation, the SBP 07 showed a more negative pressure build-up compared with the DE 5. However, in a dynamic situation, the DE 5 generated a more negative pressure, resulting in a higher suction capacity. Employment of the DE 5 at a flow rate of 18 litre min(-1) allowed a minute volume through the transtracheal catheter of up to 8.27 litre min(-1) at a compliance of 100 ml cm H(2)O(-1). The efficiency of the DE 5 depended on the flow rate of the driving gas and the compliance of the lung simulator. In laboratory tests, the DE 5 is an optimized ventilation ejector suitable for applying expiratory ventilation assistance. Further research may confirm the clinical applicability as a portable emergency ventilator for use with small-bore catheters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apte, Michael G.; Mendell, Mark J.; Sohn, Michael D.
Through mass-balance modeling of various ventilation scenarios that might satisfy the ASHRAE 62.1 Indoor Air Quality (IAQ) Procedure, we estimate indoor concentrations of contaminants of concern (COCs) in California “big box” stores, compare estimates to available thresholds, and for selected scenarios estimate differences in energy consumption. Findings are intended to inform decisions on adding performance-based approaches to ventilation rate (VR) standards for commercial buildings. Using multi-zone mass-balance models and available contaminant source rates, we estimated concentrations of 34 COCs for multiple ventilation scenarios: VRmin (0.04 cfm/ft2 ), VRmax (0.24 cfm/ft2 ), and VRmid (0.14 cfm/ft2 ). We compared COC concentrationsmore » with available health, olfactory, and irritant thresholds. We estimated building energy consumption at different VRs using a previously developed EnergyPlus model. VRmax did control all contaminants adequately, but VRmin did not, and VRmid did so only marginally. Air cleaning and local ventilation near strong sources both showed promise. Higher VRs increased indoor concentrations of outdoor air pollutants. Lowering VRs in big box stores in California from VRmax to VRmid would reduce total energy use by an estimated 6.6% and energy costs by 2.5%. Reducing the required VRs in California’s big box stores could reduce energy use and costs, but poses challenges for health and comfort of occupants. Source removal, air cleaning, and local ventilation may be needed at reduced VRs, and even at current recommended VRs. Also, alternative ventilation strategies taking climate and season into account in ventilation schedules may provide greater energy cost savings than constant ventilation rates, while improving IAQ.« less
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment. 108.437 Section 108.437 Shipping COAST GUARD, DEPARTMENT OF... Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.437 Pipe sizes and discharge rates for...
Risk factors associated with development of ventilator associated pneumonia.
Noor, Ahmed; Hussain, Syed Fayyaz
2005-02-01
To assess the risk factors associated with development of ventilator associated pneumonia (VAP). A case control study. Intensive Care Unit (ICU) at the Aga Khan University Hospital, Karachi, between January 1999 and June 2000. All patients with assisted mechanical ventilation were assessed for the development of VAP. Risk factors associated with development of VAP were determined. Adult patients who developed pneumonia, 48 hours after ventilation, were called cases while those who did not develop pneumonia were called controls. Seventy (28%) out of 250 mechanically ventilated patients developed VAP (rate of VAP was 26 cases per 1000 ventilator days). Shock during first 48 hours of ventilation (odds ratio (OR), 5.95; 95% confidence interval (CI), 2.83-12.52), transport out of ICU during mechanical ventilation (OR, 6.0; 95% CI, 2.92-12.37), re-intubation (OR, 4.23; 95% CI, 2.53-9.85), prior episode of aspiration of gastric content (OR, 3.07; 95% CI, 1.35-7.01), and use of antibiotics prior to intubation (OR,2.55; 95% CI, 1.20-5.41) were found to be independently associated with a higher risk of developing VAP. Gram negative organisms and Staphylococcus aureus were responsible for over 90% of cases. Patients with VAP had higher crude mortality rate (57.1%) compared with controls (32.2%). Ventilator associated pneumonia is associated with a high mortality. This study has identified risk factors associated with VAP.
Short-term airing by natural ventilation - implication on IAQ and thermal comfort.
Heiselberg, P; Perino, M
2010-04-01
The need to improve the energy efficiency of buildings requires new and more efficient ventilation systems. It has been demonstrated that innovative operating concepts that make use of natural ventilation seem to be more appreciated by occupants. Among the available ventilation strategies that are currently available, buoyancy driven, single-sided natural ventilation has proved to be very effective and can provide high air change rates for temperature and Indoor Air Quality (IAQ) control. However, to promote a wider distribution of these systems an improvement in the knowledge of their working principles is necessary. The present study analyses and presents the results of an experimental evaluation of airing performance in terms of ventilation characteristics, IAQ and thermal comfort. It includes investigations of the consequences of opening time, opening frequency, opening area and expected airflow rate, ventilation efficiency, thermal comfort and dynamic temperature conditions. A suitable laboratory test rig was developed to perform extensive experimental analyses of the phenomenon under controlled and repeatable conditions. The results showed that short-term window airing is very effective and can provide both acceptable IAQ and thermal comfort conditions in buildings. Practical Implications This study gives the necessary background and in-depth knowledge of the performance of window airing by single-sided natural ventilation necessary for the development of control strategies for window airing (length of opening period and opening frequency) for optimum IAQ and thermal comfort in naturally ventilated buildings.
Assessment of Factors Related to Auto-PEEP.
Natalini, Giuseppe; Tuzzo, Daniele; Rosano, Antonio; Testa, Marco; Grazioli, Michele; Pennestrì, Vincenzo; Amodeo, Guido; Marsilia, Paolo F; Tinnirello, Andrea; Berruto, Francesco; Fiorillo, Marialinda; Filippini, Matteo; Peratoner, Alberto; Minelli, Cosetta; Bernardini, Achille
2016-02-01
Previous physiological studies have identified factors that are involved in auto-PEEP generation. In our study, we examined how much auto-PEEP is generated from factors that are involved in its development. One hundred eighty-six subjects undergoing controlled mechanical ventilation with persistent expiratory flow at the beginning of each inspiration were enrolled in the study. Volume-controlled continuous mandatory ventilation with PEEP of 0 cm H2O was applied while maintaining the ventilator setting as chosen by the attending physician. End-expiratory and end-inspiratory airway occlusion maneuvers were performed to calculate respiratory mechanics, and tidal flow limitation was assessed by a maneuver of manual compression of the abdomen. The variable with the strongest effect on auto-PEEP was flow limitation, which was associated with an increase of 2.4 cm H2O in auto-PEEP values. Moreover, auto-PEEP values were directly related to resistance of the respiratory system and body mass index and inversely related to expiratory time/time constant. Variables that were associated with the breathing pattern (tidal volume, frequency minute ventilation, and expiratory time) did not show any relationship with auto-PEEP values. The risk of auto-PEEP ≥5 cm H2O was increased by flow limitation (adjusted odds ratio 17; 95% CI: 6-56.2), expiratory time/time constant ratio <1.85 (12.6; 4.7-39.6), respiratory system resistance >15 cm H2O/L s (3; 1.3-6.9), age >65 y (2.8; 1.2-6.5), and body mass index >26 kg/m(2) (2.6; 1.1-6.1). Flow limitation, expiratory time/time constant, resistance of the respiratory system, and obesity are the most important variables that affect auto-PEEP values. Frequency expiratory time, tidal volume, and minute ventilation were not independently associated with auto-PEEP. Therapeutic strategies aimed at reducing auto-PEEP and its adverse effects should be primarily oriented to the variables that mainly affect auto-PEEP values. Copyright © 2016 by Daedalus Enterprises.
Wang, Ruichun; Chen, Junping; Wu, Guorong
2015-01-01
Postoperative cognitive dysfunction (POCD) is a subtle impairment of cognitive abilities and can manifest on different neuropsychological features in the early postoperative period. It has been proved that the use of mechanical ventilation (MV) increased the development of delirium and POCD. However, the impact of variable and conventional lung protective mechanical ventilation on the incidence of POCD still remains unknown, which was the aim of this study. 162 patients scheduled to undergo elective gastrointestinal tumor resection via laparotomy in Ningbo No. 2 hospital with expected duration >2 h from June, 2013 to June, 2015 were enrolled in this study. Patients included were divided into two groups according to the scheme of lung protective MV, variable ventilation group (VV group, n=79) and conventional ventilation group (CV group, n=83) by randomization performed by random block randomization. The plasma levels of inflammatory cytokines, characteristics of the surgical procedure, incidence of delirium and POCD were collected and compared. Postoperative delirium was detected in 36 of 162 patients (22.2%) and 12 patients of these (16.5%) belonged to the VV group while 24 patients (28.9%) were in the CV group (P=0.036). POCD on the seventh postoperative day in CV group (26/83, 31.3%) was increased in comparison with the VV group (14/79, 17.7%) with significant statistical difference (P=0.045). The levels of inflammatory cytokines were all significantly higher in CV group than those in VV group on the 1st postoperative day (P<0.05). On 7th postoperative day, the levels of IL-6 and TNF-α in CV group remained much higher compared with VV group (P<0.05). Variable vs conventional lung protective MV decreased the incidence of postoperative delirium and POCD by reducing the systemic proinflammatory response.
Fatemian, Marzieh; Herigstad, Mari; Croft, Quentin P P; Formenti, Federico; Cardenas, Rosa; Wheeler, Carly; Smith, Thomas G; Friedmannova, Maria; Dorrington, Keith L; Robbins, Peter A
2016-03-01
Pulmonary ventilation and pulmonary arterial pressure both rise progressively during the first few hours of human acclimatization to hypoxia. These responses are highly variable between individuals, but the origin of this variability is unknown. Here, we sought to determine whether the variabilities between different measures of response to sustained hypoxia were related, which would suggest a common source of variability. Eighty volunteers individually underwent an 8-h isocapnic exposure to hypoxia (end-tidal P(O2)=55 Torr) in a purpose-built chamber. Measurements of ventilation and pulmonary artery systolic pressure (PASP) assessed by Doppler echocardiography were made during the exposure. Before and after the exposure, measurements were made of the ventilatory sensitivities to acute isocapnic hypoxia (G(pO2)) and hyperoxic hypercapnia, the latter divided into peripheral (G(pCO2)) and central (G(cCO2)) components. Substantial acclimatization was observed in both ventilation and PASP, the latter being 40% greater in women than men. No correlation was found between the magnitudes of pulmonary ventilatory and pulmonary vascular responses. For G(pO2), G(pCO2) and G(cC O2), but not the sensitivity of PASP to acute hypoxia, the magnitude of the increase during acclimatization was proportional to the pre-acclimatization value. Additionally, the change in G(pO2) during acclimatization to hypoxia correlated well with most other measures of ventilatory acclimatization. Of the initial measurements prior to sustained hypoxia, only G(pCO2) predicted the subsequent rise in ventilation and change in G(pO2) during acclimatization. We conclude that the magnitudes of the ventilatory and pulmonary vascular responses to sustained hypoxia are predominantly determined by different factors and that the initial G(pCO2) is a modest predictor of ventilatory acclimatization. © 2015 The Authors. The Journal of Physiology published by John Wiley & Sons Ltd on behalf of The Physiological Society.
Younan, Duraid; Griffin, Russell; Swain, Thomas; Pittet, Jean-Francois; Camins, Bernard
2017-08-01
The Centers for Disease Control and Prevention's National Healthcare Safety Network (NHSN) replaced its old definition for ventilator-associated pneumonia (VAP) with the ventilator-associated events algorithm in 2013. We sought to compare the outcome of trauma patients meeting the definitions for VAP in the two modules. Trauma patients with blunt or penetrating injuries and with at least 2 d of ventilator support were identified from the trauma registry from 2013 to 2014. VAP was determined using two methods: (1) VAP as defined by the "old," clinically based NHSN definition and (2) possible VAP as defined by the updated "new" NHSN definition. Cohen's kappa statistic was determined to compare the two definitions for VAP. To compare demographic and clinical outcomes, the chi-square and Student's t-tests were used for categorical and continuous variables, respectively. From 2013 to 2014, there were 1165 trauma patients admitted who had at least 2 d of ventilator support. Seventy-eight patients (6.6%) met the "new" NHSN definition for possible VAP, 361 patients (30.9%) met the "old" definition of VAP, and 68 patients (5.8%) met both definitions. The kappa statistic between VAP as defined by the "new" and "old" definitions was 0.22 (95% confidence interval, 0.17-0.27). There were no differences in age, gender, race, or injury severity score when comparing patients who met the different definitions. Those satisfying both definitions had longer ventilator support days (P = 0.0009), intensive care unit length of stay (LOS; P = 0.0003), and hospital LOS (P = 0.0344) when compared with those meeting only one definition. There was no difference in mortality for those meeting both and those meeting the old definition for VAP; patients meeting both definitions had higher respiratory rate at arrival (P = 0.0178). There was no difference in mortality between patients meeting the "old" and "new" NHSN definitions for VAP; those who met "both" definitions had longer ventilator support days, intensive care unit, and hospital LOS. Copyright © 2017 Elsevier Inc. All rights reserved.
Almuneef, Maha; Memish, Ziad A; Balkhy, Hanan H; Alalem, Hala; Abutaleb, Abdulrahman
2004-09-01
To describe the rate, risk factors, and outcome of ventilator-associated pneumonia (VAP) in pediatric patients. This prospective surveillance study of VAP among all patients receiving mechanical ventilation for 48 hours or more admitted to a pediatric intensive care unit (PICU) in Saudi Arabia from May 2000 to November 2002 used National Nosocomial Infections Surveillance (NNIS) System definitions. Three hundred sixty-one eligible patients were enrolled. Most were Saudi with a mean age of 28.6 months. Thirty-seven developed VAP. The mean VAP rate was 8.87 per 1,000 ventilation-days with a ventilation utilization rate of 47%. The mean duration of mechanical ventilation was 21 days for VAP patients and 10 days for non-VAP patients. The mean PICU stay was 34 days for VAP patients and 15 days for non-VAP patients. Among VAP patients, Pseudomonas aeruginosa was the most common organism, followed by Staphylococcus aureus. Other gram-negative organisms were also encountered. There was no significant difference between VAP and non-VAP patients regarding mortality rate. Witnessed aspiration, reintubation, prior antibiotic therapy, continuous enteral feeding, and bronchoscopy were associated with VAP. On multiple logistic regression analysis, only prior antibiotic therapy, continuous enteral feeding, and bronchoscopy were independent predictors of VAP. The mean VAP rate in this hospital was higher than that reported by NNIS System surveillance of PICUs. This study has established a benchmark for future studies of VAP in the pediatric intensive care population in Saudi Arabia. Additional studies from the region are necessary for comparison and development of preventive measures.
van Loon, K; Breteler, M J M; van Wolfwinkel, L; Rheineck Leyssius, A T; Kossen, S; Kalkman, C J; van Zaane, B; Peelen, L M
2016-12-01
Altered respiratory rate is one of the first symptoms of medical conditions that require timely intervention, e.g., sepsis or opioid-induced respiratory depression. To facilitate continuous respiratory rate monitoring on general hospital wards a contactless, non-invasive, prototype monitor was developed using frequency modulated continuous wave radar. We aimed to study whether radar can reliably measure respiratory rate in postoperative patients. In a diagnostic cross-sectional study patients were monitored with the radar and the reference monitor (pneumotachograph during mechanical ventilation and capnography during spontaneous breathing). Eight patients were included; yielding 796 min of observation time during mechanical ventilation and 521 min during spontaneous breathing. After elimination of movement artifacts the bias and 95 % limits of agreement for mechanical ventilation and spontaneous breathing were -0.12 (-1.76 to 1.51) and -0.59 (-5.82 to 4.63) breaths per minute respectively. The radar was able to accurately measure respiratory rate in mechanically ventilated patients, but the accuracy decreased during spontaneous breathing.
Zanotto, F P; Wheatly, M G; Reiber, C L; Gannon, A T; Jalles-Filho, E
2004-01-01
There are few intraspecific studies relating physiological parameters to body mass. This study relates scaling of ionic regulation and respiratory parameters with body mass in crayfish (Procambarus clarkii). These animals were chosen because of their direct development, spanning four orders of magnitude in body mass. Usually, these animals are hyperregulators and must maintain hemolymph electrolyte levels above those in the ambient freshwater. This is especially important in the postmolt, when ion imbalance can occur. Maintaining hemolymph ion levels above ambient involves active processes that are independently related to metabolic rate, ventilation, and circulation. Therefore, this study investigates relationships among size and ionic regulation, heart rate, and ventilation in crayfish, spanning a size range of 0.003-24 g. Postmolt net ion uptake of Ca, titratable base, Na, Cl, and NH4 increase with body mass (positive allometry) with slopes of 0.92, 0.79, 0.90, 0.84, and 0.87, respectively. Between 72% and 97% of variation in ionic regulation was related to body mass. The slopes differed from each other for Ca and titratable base but not for Na, Cl, and NH4. For heart rate and ventilation rate, different relationships were derived for animals smaller and larger than 0.01 g (between first and third instar). Animals larger than 0.01 g show a negative allometric relationship between heart rate and body size ([body mass](0.15)), while smaller animals show positive allometry with body size, but only 29% of variation in heart rate is explained by body size alone. For ventilation rates, the negative allometry with body size for animals larger than 0.01 g is present, but less than 15% of variation in ventilation rate is explained by size, while for smaller animals the size dependency disappears. Based on these results, predictions of physiological parameters such as ionic regulation based on body size are useful in crayfish, but estimates of respiratory parameters and body size should be used with caution.
Frequency and Intensive Care Related Risk Factors of Pneumothorax in Ventilated Neonates
Bhat Yellanthoor, Ramesh; Ramdas, Vidya
2014-01-01
Objectives. Relationships of mechanical ventilation to pneumothorax in neonates and care procedures in particular are rarely studied. We aimed to evaluate the relationship of selected ventilator variables and risk events to pneumothorax. Methods. Pneumothorax was defined as accumulation of air in pleural cavity as confirmed by chest radiograph. Relationship of ventilator mode, selected settings, and risk procedures prior to detection of pneumothorax was studied using matched controls. Results. Of 540 neonates receiving mechanical ventilation, 10 (1.85%) were found to have pneumothorax. Respiratory distress syndrome, meconium aspiration syndrome, and pneumonia were the underlying lung pathology. Pneumothorax mostly (80%) occurred within 48 hours of life. Among ventilated neonates, significantly higher percentage with pneumothorax received mandatory ventilation than controls (70% versus 20%; P < 0.01). Peak inspiratory pressure >20 cm H2O and overventilation were not significantly associated with pneumothorax. More cases than controls underwent care procedures in the preceding 3 hours of pneumothorax event. Mean airway pressure change (P = 0.052) and endotracheal suctioning (P = 0.05) were not significantly associated with pneumothorax. Reintubation (P = 0.003), and bagging (P = 0.015) were significantly associated with pneumothorax. Conclusion. Pneumothorax among ventilated neonates occurred at low frequency. Mandatory ventilation and selected care procedures in the preceding 3 hours had significant association. PMID:24876958
40 CFR 98.323 - Calculating GHG emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... systems (metric tons CH4). CH4V = Quarterly CH4 liberated from each ventilation monitoring point (metric... vent holes are collected, you must calculate the quarterly CH4 liberated from the ventilation system... CH4 liberated from a ventilation monitoring point (metric tons CH4). V = Volumetric flow rate for the...
Field evaluation of ventilation system performance in enclosed parking garages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayari, A.M.; Grot, D.A.; Krarti, M.
2000-07-01
This paper summarizes the results of a field study to determine the ventilation requirements and the contaminant levels in existing enclosed parking garages. The testing was conducted in seven parking garages with different sizes, traffic flow patterns, vehicle types, and locations. In particular, the study compares the actual ventilation rates measured using the tracer gas technique with the ventilation requirements of ANSI/ASHRAE Standard 62-1989. In addition, the field test evaluated the effectiveness of the existing ventilation systems in maintaining acceptable contaminant levels within enclosed parking garages.
Elective ventilation for organ donation: law, policy and public ethics.
Coggon, John
2013-03-01
This paper examines questions concerning elective ventilation, contextualised within English law and policy. It presents the general debate with reference both to the Exeter Protocol on elective ventilation, and the considerable developments in legal principle since the time that that protocol was declared to be unlawful. I distinguish different aspects of what might be labelled elective ventilation policies under the following four headings: 'basic elective ventilation'; 'epistemically complex elective ventilation'; 'practically complex elective ventilation'; and 'epistemically and practically complex elective ventilation'. I give a legal analysis of each. In concluding remarks on their potential practical viability, I emphasise the importance not just of ascertaining the legal and ethical acceptability of these and other forms of elective ventilation, but also of assessing their professional and political acceptability. This importance relates both to the successful implementation of the individual practices, and to guarding against possible harmful effects in the wider efforts to increase the rates of posthumous organ donation.
Prevalence and test characteristics of national health safety network ventilator-associated events.
Lilly, Craig M; Landry, Karen E; Sood, Rahul N; Dunnington, Cheryl H; Ellison, Richard T; Bagley, Peter H; Baker, Stephen P; Cody, Shawn; Irwin, Richard S
2014-09-01
The primary aim of the study was to measure the test characteristics of the National Health Safety Network ventilator-associated event/ventilator-associated condition constructs for detecting ventilator-associated pneumonia. Its secondary aims were to report the clinical features of patients with National Health Safety Network ventilator-associated event/ventilator-associated condition, measure costs of surveillance, and its susceptibility to manipulation. Prospective cohort study. Two inpatient campuses of an academic medical center. Eight thousand four hundred eight mechanically ventilated adults discharged from an ICU. None. The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs detected less than a third of ventilator-associated pneumonia cases with a sensitivity of 0.325 and a positive predictive value of 0.07. Most National Health Safety Network ventilator-associated event/ventilator-associated condition cases (93%) did not have ventilator-associated pneumonia or other hospital-acquired complications; 71% met the definition for acute respiratory distress syndrome. Similarly, most patients with National Health Safety Network probable ventilator-associated pneumonia did not have ventilator-associated pneumonia because radiographic criteria were not met. National Health Safety Network ventilator-associated event/ventilator-associated condition rates were reduced 93% by an unsophisticated manipulation of ventilator management protocols. The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs failed to detect many patients who had ventilator-associated pneumonia, detected many cases that did not have a hospital complication, and were susceptible to manipulation. National Health Safety Network ventilator-associated event/ventilator-associated condition surveillance did not perform as well as ventilator-associated pneumonia surveillance and had several undesirable characteristics.
Household ventilation and tuberculosis transmission in Kampala, Uganda.
Chamie, G; Wandera, B; Luetkemeyer, A; Bogere, J; Mugerwa, R D; Havlir, D V; Charlebois, E D
2013-06-01
To test the feasibility of measuring household ventilation and evaluate whether ventilation is associated with tuberculosis (TB) in household contacts in Kampala, Uganda. Adults with pulmonary TB and their household contacts received home visits to ascertain social and structural household characteristics. Ventilation was measured in air changes per hour (ACH) in each room by raising carbon dioxide (CO₂) levels using dry ice, removing the dry ice, and measuring changes in the natural log of CO₂ (lnCO2) over time. Ventilation was compared in homes with and without co-prevalent TB. Members of 61 of 66 (92%) households approached were enrolled. Households averaged 5.4 residents/home, with a median of one room/home. Twelve homes (20%) reported co-prevalent TB in household contacts. Median ventilation for all rooms was 14 ACH (interquartile range [IQR] 10-18). Median ventilation was 12 vs. 15 ACH in index cases' sleeping rooms in households with vs. those without co-prevalent TB (P = 0.12). Among smear-positive indexes not infected by the human immunodeficiency virus (HIV), median ventilation was 11 vs. 17 ACH in index cases' sleeping rooms in homes with vs. those without co-prevalent TB (P = 0.1). Our findings provide evidence that a simple CO₂ decay method used to measure ventilation in clinical settings can be adapted to homes, adding a novel tool and a neglected variable, ventilation, to the study of household TB transmission.
Evaluation of indoor radon equilibrium factor using CFD modeling and resulting annual effective dose
NASA Astrophysics Data System (ADS)
Rabi, R.; Oufni, L.
2018-04-01
The equilibrium factor is an important parameter for reasonably estimating the population dose from radon. However, the equilibrium factor value depended mainly on the ventilation rate and the meteorological factors. Therefore, this study focuses on investigating numerically the influence of the ventilation rate, temperature and humidity on equilibrium factor between radon and its progeny. The numerical results showed that ventilation rate, temperature and humidity have significant impacts on indoor equilibrium factor. The variations of equilibrium factor with the ventilation, temperature and relative humidity are discussed. Moreover, the committed equivalent doses due to 218Po and 214Po radon short-lived progeny were evaluated in different tissues of the respiratory tract of the members of the public from the inhalation of indoor air. The annual effective dose due to radon short lived progeny from the inhalation of indoor air by the members of the public was investigated.
Shaughnessy, R J; Haverinen-Shaughnessy, U; Nevalainen, A; Moschandreas, D
2006-12-01
Poor conditions leading to substandard indoor air quality (IAQ) in classrooms have been frequently cited in the literature over the past two decades. However, there is limited data linking poor IAQ in the classrooms to student performance. Whereas, it is assumed that poor IAQ results in reduced attendance and learning potential, and subsequent poor student performance, validating this hypothesis presents a challenge in today's school environment. This study explores the association between student performance on standardized aptitude tests that are administered to students on a yearly basis, to classroom carbon dioxide (CO2) concentrations, which provide a surrogate of ventilation being provided to each room. Data on classroom CO2 concentrations (over a 4-5 h time span within a typical school day) were recorded in fifth grade classrooms in 54 elementary schools within a school district in the USA. Results from this preliminary study yield a significant (P < 0.10) association between classroom-level ventilation rate and test results in math. They also indicate that non-linear effects may need to be considered for better representation of the association. A larger sample size is required in order to draw more definitive conclusions. Practical Implications Future studies could focus on (1) gathering more evidence on the possible association between classroom ventilation rates and students' academic performance; (2) the linear/non-linear nature of the association; and (3) whether it is possible to detect 'no observed adverse effect level' for adequate ventilation with respect to academic performance in schools. All of this information could be used to improve guidance and take regulatory actions to ensure adequate ventilation in schools. The high prevalence of low ventilation rates, combined with the growing evidence of the positive impact that sufficient ventilation has on human performance, suggests an opportunity for improving design and management of school facilities.
Can, Fulva Kamit; Anil, Ayse Berna; Anil, Murat; Zengin, Neslihan; Bal, Alkan; Bicilioglu, Yuksel; Gokalp, Gamze; Durak, Fatih; Ince, Gulberat
2017-10-15
To analyze the change in quality indicators due to the use of high-flow nasal cannula therapy as a non-invasive ventilation method in children with respiratory distress/failure in a non-invasive ventilation device-free pediatric intensive care unit. Retrospective chart review of children with respiratory distress/failure admitted 1 year before (period before high-flow nasal cannula therapy) and 1 year after (period after high-flow nasal cannula therapy) the introduction of high-flow nasal cannula therapy. We compared quality indicators as rate of mechanical ventilation, total duration of mechanical ventilation, rate of re-intubation, pediatric intensive care unit length of stay, and mortality rate between these periods. Between November 2012 and November 2014, 272 patients: 141 before and 131 after high-flow nasal cannula therapy were reviewed (median age was 20.5 mo). Of the patients in the severe respiratory distress/failure subgroup, the rate of intubation was significantly lower in period after than in period before high-flow nasal cannula therapy group (58.1% vs. 76.1%; P <0.05). The median pediatric intensive care unit length of stay was significantly shorter in patients who did not require mechanical ventilation in the period after than in the period before high-flow nasal cannula therapy group (3d vs. 4d; P<0,05). Implementation of high-flow nasal cannula therapy in pediatric intensive care unit significantly improves the quality of therapy and its outcomes.
Ventilation requirements in buildings—I. Control of occupancy odor and tobacco smoke odor
NASA Astrophysics Data System (ADS)
Cain, William S.; Leaderer, Brian P.; Isseroff, Ruth; Berglund, Larry G.; Huey, Raymond J.; Lipsitt, Eric D.; Perlman, Dan
Psychophysical measurements of odor, supplemented with certain physical measurements, were taken to examine ventilation requirements during smoking and nonsmoking occupancy in an environmental chamber. The facility provided the means to compare impressions of visitors (persons who inhaled air from the chamber only briefly) with impressions of occupants. For nonsmoking occupancy, 47 combinations of temperature, humidity, ventilation rate and occupancy density were examined. Odor level depended entirely on ventilation rate per person irrespective of the number of persons in the chamber. The ventilation necessary to satisfy 75 % of visitors equalled only about 4 ℓ s -1 per person. Occupants, however, were satisfied with far less. In an array of 38 conditions of smoking occupancy, the ventilation deemed necessary to satisfy 75 % of visitors under customary conditions of occupancy equalled 17.5 ℓ s -1 per person. For both smoking and nonsmoking conditions, a combination of high temperature (25.5°C) and humidity (r.h. > 70 %) exacerbated the odor problem. During smoking, carbon monoxide rarely reached dangerous levels, but suspended particulate matter often reached levels considered unacceptable outdoors. The results highlight the energy penalty incurred in ventilation for smoking occupancy.
Spieth, P M; Güldner, A; Uhlig, C; Bluth, T; Kiss, T; Conrad, C; Bischlager, K; Braune, A; Huhle, R; Insorsi, A; Tarantino, F; Ball, L; Schultz, M J; Abolmaali, N; Koch, T; Pelosi, P; Gama de Abreu, M
2018-03-01
Experimental studies showed that controlled variable ventilation (CVV) yielded better pulmonary function compared to non-variable ventilation (CNV) in injured lungs. We hypothesized that CVV improves intraoperative and postoperative respiratory function in patients undergoing open abdominal surgery. Fifty patients planned for open abdominal surgery lasting >3 h were randomly assigned to receive either CVV or CNV. Mean tidal volumes and PEEP were set at 8 ml kg -1 (predicted body weight) and 5 cm H 2 O, respectively. In CVV, tidal volumes varied randomly, following a normal distribution, on a breath-by-breath basis. The primary endpoint was the forced vital capacity (FVC) on postoperative Day 1. Secondary endpoints were oxygenation, non-aerated lung volume, distribution of ventilation, and pulmonary and extrapulmonary complications until postoperative Day 5. FVC did not differ significantly between CVV and CNV on postoperative Day 1, 61.5 (standard deviation 22.1) % vs 61.9 (23.6) %, respectively; mean [95% confidence interval (CI)] difference, -0.4 (-13.2-14.0), P=0.95. Intraoperatively, CVV did not result in improved respiratory function, haemodynamics, or redistribution of ventilation compared to CNV. Postoperatively, FVC, forced expiratory volume at the first second (FEV 1 ), and FEV 1 /FVC deteriorated, while atelectasis volume and plasma levels of interleukin-6 and interleukin-8 increased, but values did not differ between groups. The incidence of postoperative pulmonary and extrapulmonary complications was comparable in CVV and CNV. In patients undergoing open abdominal surgery, CVV did not improve intraoperative and postoperative respiratory function compared with CNV. NCT 01683578. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.
Fernández, Rafael; Altaba, Susana; Cabre, Lluis; Lacueva, Victoria; Santos, Antonio; Solsona, Jose-Felipe; Añon, Jose-Manuel; Catalan, Rosa-Maria; Gutierrez, Maria-Jose; Fernandez-Cid, Ramon; Gomez-Tello, Vicente; Curiel, Emilio; Fernandez-Mondejar, Enrique; Oliva, Joan-Carles; Tizon, Ana Isabel; Gonzalez, Javier; Monedero, Pablo; Sanchez, Manuela Garcia; de la Torre, M Victoria; Ibañez, Pedro; Frutos, Fernando; Del Nogal, Frutos; Gomez, M Jesus; Marcos, Alfredo; Vera, Paula; Serrano, Jose Manuel; Umaran, Isabel; Carrillo, Andres; Lopez-Pueyo, M-Jose; Rascado, Pedro; Balerdi, Begoña; Suberviola, Borja; Hernandez, Gonzalo
2013-10-01
Recent studies have found an association between increased volume and increased intensive care unit (ICU) survival; however, this association might not hold true in ICUs with permanent intensivist coverage. Our objective was to determine whether ICU volume correlates with survival in the Spanish healthcare system. Post hoc analysis of a prospective study of all patients admitted to 29 ICUs during 3 months. At ICU discharge, the authors recorded demographic variables, severity score, and specific ICU treatments. Follow-up variables included ICU readmission and hospital mortality. Statistics include logistic multivariate analyses for hospital mortality according to quartiles of volume of patients. The authors studied 4,001 patients with a mean predicted risk of death of 23% (range at hospital level: 14-46%). Observed hospital mortality was 19% (range at hospital level: 11-35%), resulting in a standardized mortality ratio of 0.81 (range: 0.5-1.3). Among the 1,923 patients needing mechanical ventilation, the predicted risk of death was 32% (14-60%) and observed hospital mortality was 30% (12-61%), resulting in a standardized mortality ratio of 0.96 (0.5-1.7). The authors found no correlation between standardized mortality ratio and ICU volume in the entire population or in mechanically ventilated patients. Only mechanically ventilated patients in very low-volume ICUs had slightly worse outcome. In the currently studied healthcare system characterized by 24/7 intensivist coverage, the authors found wide variability in outcome among ICUs even after adjusting for severity of illness but no relationship between ICU volume and outcome. Only mechanically ventilated patients in very low-volume centers had slightly worse outcomes.
Murphy, Patrick B; Brignall, Kate; Moxham, John; Polkey, Michael I; Davidson, A Craig; Hart, Nicholas
2012-01-01
High-intensity (high-pressure and high backup rate) noninvasive ventilation has recently been advocated for the management of stable hypercapnic chronic obstructive pulmonary disease (COPD). However, the relative contributions of high inspiratory pressure and high backup rate to ventilator adherence and physiological outcome have not been investigated. Patients with stable hypercapnic COPD (daytime PaCO(2) > 6 kPa) and nocturnal hypoventilation were enrolled. Patients were randomly allocated to high-pressure and high backup rate (high-intensity) and high-pressure and low backup rate (high-pressure) for a 6-week period. At the end of the first treatment period, patients were switched to the alternative treatment. The primary outcome measure was mean nightly ventilator usage. Twelve patients were recruited, with seven completing the 12-week trial protocol. The mean patient age was 71 ± 8 years, with a forced expiratory volume in one second (FEV(1))/forced vital capacity (FVC) of 50% ± 13% and FEV(1) of 32% ± 12%. The baseline PaCO(2) and PaO(2) were 8.6 ± 1.7 kPa and 7.3 ± 1.4 kPa, respectively. There was no significant difference demonstrated in mean nightly ventilator usage between the high-intensity and high-pressure groups (difference of 4 minutes; 95% confidence interval -45 to 53; P = 0.9). Furthermore, there were no differences in any of the secondary endpoints, with the exception of the respiratory domain of the Severe Respiratory Insufficiency questionnaire, which was lower in the high-intensity arm than in the high-pressure arm (57 ± 11 versus 69 ± 16; P < 0.05). There was no additional benefit, in terms of night-time ventilator adherence or any of the other measured parameters, demonstrated by addition of a high backup rate to high-pressure noninvasive ventilation. These data suggest that it is the high-pressure component of the high-intensity noninvasive ventilation approach that plays the important therapeutic role in the management of hypercapnic respiratory failure in COPD patients.
Aerosol delivery with two ventilation modes during mechanical ventilation: a randomized study.
Dugernier, Jonathan; Reychler, Gregory; Wittebole, Xavier; Roeseler, Jean; Depoortere, Virginie; Sottiaux, Thierry; Michotte, Jean-Bernard; Vanbever, Rita; Dugernier, Thierry; Goffette, Pierre; Docquier, Marie-Agnes; Raftopoulos, Christian; Hantson, Philippe; Jamar, François; Laterre, Pierre-François
2016-12-01
Volume-controlled ventilation has been suggested to optimize lung deposition during nebulization although promoting spontaneous ventilation is targeted to avoid ventilator-induced diaphragmatic dysfunction. Comparing topographic aerosol lung deposition during volume-controlled ventilation and spontaneous ventilation in pressure support has never been performed. The aim of this study was to compare lung deposition of a radiolabeled aerosol generated with a vibrating-mesh nebulizer during invasive mechanical ventilation, with two modes: pressure support ventilation and volume-controlled ventilation. Seventeen postoperative neurosurgery patients without pulmonary disease were randomly ventilated in pressure support or volume-controlled ventilation. Diethylenetriaminepentaacetic acid labeled with technetium-99m (2 mCi/3 mL) was administrated using a vibrating-mesh nebulizer (Aerogen Solo(®), provided by Aerogen Ltd, Galway, Ireland) connected to the endotracheal tube. Pulmonary and extrapulmonary particles deposition was analyzed using planar scintigraphy. Lung deposition was 10.5 ± 3.0 and 15.1 ± 5.0 % of the nominal dose during pressure support and volume-controlled ventilation, respectively (p < 0.05). Higher endotracheal tube and tracheal deposition was observed during pressure support ventilation (27.4 ± 6.6 vs. 20.7 ± 6.0 %, p < 0.05). A similar penetration index was observed for the right (p = 0.210) and the left lung (p = 0.211) with both ventilation modes. A high intersubject variability of lung deposition was observed with both modes regarding lung doses, aerosol penetration and distribution between the right and the left lung. In the specific conditions of the study, volume-controlled ventilation was associated with higher lung deposition of nebulized particles as compared to pressure support ventilation. The clinical benefit of this effect warrants further studies. Clinical trial registration NCT01879488.
NASA Astrophysics Data System (ADS)
Abi-Esber, L.; El-Fadel, M.
2013-12-01
In this study, in-vehicle and out-vehicle concentrations of fine particulate matter (PM2.5) and carbon monoxide (CO) are measured to assess commuter's exposure in a commercial residential area and on a highway, under three popular ventilation modes namely, one window half opened, air conditioning on fresh air intake, and air conditioning on recirculation and examine its relationship to scarcely studied parameters including self pollution, out-vehicle sample intake location and meteorological gradients. Self pollution is the intrusion of a vehicle's own engine fumes into the passenger's compartment. For this purpose, six car makes with different ages were instrumented to concomitantly monitor in- and out-vehicle PM2.5 and CO concentrations as well as meteorological parameters. Air pollution levels were unexpectedly higher in new cars compared to old cars, with in-cabin air quality most correlated to that of out-vehicle air near the front windshield. Self-pollution was observed at variable rates in three of the six tested cars. Significant correlations were identified between indoor to outdoor pressure difference and PM2.5 and CO In/Out (IO) ratios under air recirculation and window half opened ventilation modes whereas temperature and humidity difference affected CO IO ratios only under the air recirculation ventilation mode.
Bubble CPAP for respiratory distress syndrome in preterm infants.
Koti, Jagdish; Murki, Srinivas; Gaddam, Pramod; Reddy, Anupama; Reddy, M Dasaradha Rami
2010-02-01
To ascertain the immediate outcome of preterm infants with respiratory distress syndrome (RDS) on Bubble CPAP and identify risk factors associated with its failure. Prospective analytical study. Inborn preterm infants (gestation 28 to 34 weeks) admitted to the NICU with respiratory distress and chest X ray suggestive of RDS. Bubble CPAP with bi-nasal prongs. CPAP failures infants requiring ventilation in the first one week. 56 neonates were enrolled in the study. 14 (25%) babies failed CPAP. The predictors of failure were; no or only partial exposure to antenatal steroids, white-out on the chest X-ray, patent ductus arteriosus, sepsis/pneumonia and Downes score > 7 or FiO2 > or = 50% after 15-20 minutes of CPAP. Other maternal and neonatal variables did not influence the need for ventilation. Rates of mortality and duration of oxygen requirement was significantly higher in babies who failed CPAP. Only two infants developed pneumothorax. No baby had chronic lung disease. Infants with no or partial exposure to antenatal steroids, white-out chest X-ray, patent ductus arteriosus, sepsis/pneumonia and those with higher FiO2 requirement after initial stabilization on CPAP are at high risk of CPAP failure (needing mechanical ventilation). Bubble CPAP is safe for preterm infants with RDS.
Tolerance of Volume Control Noninvasive Ventilation in Subjects With Amyotrophic Lateral Sclerosis.
Martínez, Daniel; Sancho, Jesús; Servera, Emilio; Marín, Julio
2015-12-01
Noninvasive ventilation (NIV) tolerance has been identified as an independent predictor of survival in amyotrophic lateral sclerosis (ALS). Volume control continuous mandatory ventilation (VC-CMV) NIV has been associated with poor tolerance. The aim of this study was to determine the tolerance of subjects with ALS to VC-CMV NIV. This was a prospective study involving subjects with ALS who were treated with VC-CMV NIV. Respiratory and functional parameters were recorded when the subjects began ventilatory support. NIV tolerance was evaluated after 3 months. Eighty-seven subjects with ALS were included. After 3 months, 80 subjects (92%) remained tolerant of NIV. Tolerant subjects presented greater survival (median 22.0 months, 95% CI 14.78-29.21) than intolerant subjects (median 6.0 months, 95% CI 0.86-11.13) (P = .03). The variables that best predicted NIV tolerance were mechanically assisted cough peak flow (P = .01) and percentage of time spent with SpO2 < 90% at night while on NIV (P = .03) CONCLUSIONS: VC-CMV NIV provides high rates of NIV tolerance in subjects with ALS. Mechanically assisted cough peak flow and percentage of time spent with SpO2 < 90% at night while using NIV are the 2 factors associated with tolerance of VC-CMV NIV in subjects with ALS. Copyright © 2015 by Daedalus Enterprises.
Reilly-Shah, Vikas N O'; Lynde, Grant C; Mitchell, Matthew L; Maffeo, Carla L; Jabaley, Craig S; Wolf, Francis A
2018-05-30
Sugammadex can rapidly reverse deep neuromuscular blockade, but due to cost questions remain as to its optimal utilization. After introduction for unrestricted use at an academic medical center, we hypothesized that reductions would be demonstrated in the primary outcome of post-anesthesia care unit (PACU) mechanical ventilation (MV) and secondary outcomes of PACU length of stay (LOS), and emergence time (surgery end to anesthesia end time in PACU). We conducted a retrospective observational study of patients undergoing general anesthesia over a 12-month period. Using multiple variable penalized logistic regression in a one group before-and-after design, we compared categorized rates of PACU MV to examine the effect of sugammadex introduction following a post-hoc chart review to ascertain the reason for postoperative MV. Additionally, multiple variable linear regression was used to assess for differences in PACU LOS and emergence time within a propensity matched set of patients receiving neostigmine or sugammadex. 7,217 cases met inclusion criteria: 3,798 before and 3,419 after the introduction of sugammadex. The incidence of PACU MV was 2.3% before and 1.8% after (p=0.118). PACU MV due to residual neuromuscular blockade (rNMB) decreased from 0.63% to 0.20% (p=0.005). Ventilation due to other causes was unchanged. PACU LOS and emergence time were unchanged in a propensity matched set of 1,444 cases. We identified rNMB as an important contributor to PACU MV utilization and observed a significant decrease after sugammadex was introduced. The selected efficiency measures may not have been sufficiently granular to identify improvements following introduction.
Biselli, Paolo; Fricke, Kathrin; Grote, Ludger; Braun, Andrew T; Kirkness, Jason; Smith, Philip; Schwartz, Alan; Schneider, Hartmut
2018-05-01
Nasal high flow (NHF) reduces minute ventilation and ventilatory loads during sleep but the mechanisms are not clear. We hypothesised NHF reduces ventilation in proportion to physiological but not anatomical dead space.11 subjects (five controls and six chronic obstructive pulmonary disease (COPD) patients) underwent polysomnography with transcutaneous carbon dioxide (CO 2 ) monitoring under a metabolic hood. During stable non-rapid eye movement stage 2 sleep, subjects received NHF (20 L·min -1 ) intermittently for periods of 5-10 min. We measured CO 2 production and calculated dead space ventilation.Controls and COPD patients responded similarly to NHF. NHF reduced minute ventilation (from 5.6±0.4 to 4.8±0.4 L·min -1 ; p<0.05) and tidal volume (from 0.34±0.03 to 0.3±0.03 L; p<0.05) without a change in energy expenditure, transcutaneous CO 2 or alveolar ventilation. There was a significant decrease in dead space ventilation (from 2.5±0.4 to 1.6±0.4 L·min -1 ; p<0.05), but not in respiratory rate. The reduction in dead space ventilation correlated with baseline physiological dead space fraction (r 2 =0.36; p<0.05), but not with respiratory rate or anatomical dead space volume.During sleep, NHF decreases minute ventilation due to an overall reduction in dead space ventilation in proportion to the extent of baseline physiological dead space fraction. Copyright ©ERS 2018.
Fatal and near-fatal asthma in children: the critical care perspective.
Newth, Christopher J L; Meert, Kathleen L; Clark, Amy E; Moler, Frank W; Zuppa, Athena F; Berg, Robert A; Pollack, Murray M; Sward, Katherine A; Berger, John T; Wessel, David L; Harrison, Rick E; Reardon, Jean; Carcillo, Joseph A; Shanley, Thomas P; Holubkov, Richard; Dean, J Michael; Doctor, Allan; Nicholson, Carol E
2012-08-01
To characterize the clinical course, therapies, and outcomes of children with fatal and near-fatal asthma admitted to pediatric intensive care units (PICUs). This was a retrospective chart abstraction across the 8 tertiary care PICUs of the Collaborative Pediatric Critical Care Research Network (CPCCRN). Inclusion criteria were children (aged 1-18 years) admitted between 2005 and 2009 (inclusive) for asthma who received ventilation (near-fatal) or died (fatal). Data collected included medications, ventilator strategies, concomitant therapies, demographic information, and risk variables. Of the 261 eligible children, 33 (13%) had no previous history of asthma, 218 (84%) survived with no known complications, and 32 (12%) had complications. Eleven (4%) died, 10 of whom had experienced cardiac arrest before admission. Patients intubated outside the PICU had a shorter duration of ventilation (median, 25 hours vs 84 hours; P < .001). African-Americans were disproportionately represented among the intubated children and had a shorter duration of intubation. Barotrauma occurred in 15 children (6%) before admission. Pharmacologic therapy was highly variable, with similar outcomes. Of the children ventilated in the CPCCRN PICUs, 96% survived to hospital discharge. Most of the children who died experienced cardiac arrest before admission. Intubation outside the PICU was correlated with shorter duration of ventilation. Complications of barotrauma and neuromyopathy were uncommon. Practice patterns varied widely among the CPCCRN sites. Copyright © 2012 Mosby, Inc. All rights reserved.
MO-A-BRD-05: Evaluation of Composed Lung Ventilation with 4DCT and Image Registration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Du, K; Bayouth, J; Reinhardt, J
Purpose: Regional pulmonary function can be derived using fourdimensional computed tomography (4DCT) combined with deformable image registration. However, only peak inhale and exhale phases have been used thus far while the lung ventilation during intermediate phases is not considered. In our previous work, we have investigated the spatiotemporal heterogeneity of lung ventilation and its dependence on respiration effort. In this study, composed ventilation is introduced using all inspiration phases and compared to direct ventilation. Both methods are evaluated against Xe-CT derived ventilation. Methods: Using an in-house tissue volume preserving deformable image registration, unlike the direct ventilation method, which computes frommore » end expiration to end inspiration, Jacobian ventilation maps were computed from one inhale phase to the next and then composed from all inspiration steps. The two methods were compared in both patients prior to RT and mechanically ventilated sheep subjects. In addition, they wereassessed for the correlation with Xe-CT derived ventilation in sheep subjects. Annotated lung landmarks were used to evaluate the accuracy of original and composed deformation field. Results: After registration, the landmark distance for composed deformation field was always higher than that for direct deformation field (0IN to 100IN average in human: 1.03 vs 1.53, p=0.001, and in sheep: 0.80 vs0.94, p=0.009), and both increased with longer phase interval. Direct and composed ventilation maps were similar in both sheep (gamma pass rate 87.6) and human subjects (gamma pass rate 71.9),and showed consistent pattern from ventral to dorsal when compared to Xe-CT derived ventilation. Correlation coefficient between Xe-CT and composed ventilation was slightly better than the direct method but not significant (average 0.89 vs 0.85, p=0.135). Conclusion: More strict breathing control in sheep subjects may explain higher similarity between direct and composed ventilation. When compared to Xe-CT ventilation, no significant difference was found for the composed method. NIH Grant: R01 CA166703.« less
Effect of Ventilation Strategies on Residential Ozone Levels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Iain S.; Sherman, Max H.
Elevated outdoor ozone levels are associated with adverse health effects. Because people spend the vast majority of their time indoors, reduction in indoor levels of ozone of outdoor origin would lower population exposures and might also lead to a reduction in ozone-associated adverse health effects. In most buildings, indoor ozone levels are diminished with respect to outdoor levels to an extent that depends on surface reactions and on the degree to which ozone penetrates the building envelope. Ozone enters buildings from outdoors together with the airflows that are driven by natural and mechanical means, including deliberate ventilation used to reducemore » concentrations of indoor-generated pollutants. When assessing the effect of deliberate ventilation on occupant health one should consider not only the positive effects on removing pollutants of indoor origin but also the possibility that enhanced ventilation might increase indoor levels of pollutants originating outdoors. This study considers how changes in residential ventilation that are designed to comply with ASHRAE Standard 62.2 might influence indoor levels of ozone. Simulation results show that the building envelope can contribute significantly to filtration of ozone. Consequently, the use of exhaust ventilation systems is predicted to produce lower indoor ozone concentrations than would occur with balanced ventilation systems operating at the same air-exchange rate. We also investigated a strategy for reducing exposure to ozone that would deliberately reduce ventilation rates during times of high outdoor ozone concentration while still meeting daily average ventilation requirements.« less
Calibrated energy simulations of potential energy savings in actual retail buildings
NASA Astrophysics Data System (ADS)
Alhafi, Zuhaira
Retail stores are commercial buildings with high energy consumption due to their typically large volumes and long hours of operation. This dissertation assesses heating, ventilating and air conditioning saving strategies based on energy simulations with input parameters from actual retail buildings. The dissertation hypothesis is that "Retail store buildings will save a significant amount of energy by (1) modifying ventilation rates, and/or (2) resetting set point temperatures. These strategies have shown to be beneficial in previous studies. As presented in the literature review, potential energy savings ranged from 0.5% to 30% without compromising indoor thermal comfort and indoor air quality. The retail store buildings can be ventilated at rates significantly lower than rates called for in the ASHRAE Standard 62.1-2010 while maintaining acceptable indoor air quality. Therefore, two dissertation objectives are addressed: (1) Investigate opportunities to reduce ventilation rates that do not compromise indoor air quality in retail stores located in Central Pennsylvania, (2) Investigate opportunities to increase (in summer) and decrease (in winter) set point temperatures that do not compromise thermal comfort. This study conducted experimental measurements of ventilation rates required to maintain acceptable air quality and indoor environmental conditions requirements for two retail stores using ASHRAE Standard 62.1_2012. More specifically, among other parameters, occupancy density, indoor and outdoor pollutant concentrations, and indoor temperatures were measured continuously for one week interval. One of these retail stores were tested four times for a yearlong time period. Pollutants monitored were formaldehyde, carbon dioxide, particle size distributions and concentrations, as well as total volatile organic compounds. As a part of the base protocol, the number of occupants in each store was hourly counted during the test, and the results reveal that the occupant densities were approximately 20% to 30% of that called by ASHRAE 62.1. Formaldehyde was the most important contaminant of concern in retail stores investigated. Both stores exceeded the most conservative health guideline for formaldehyde (OEHHA TWA REL = 7.3 ppb). This study found that source removal and reducing the emission rate, as demonstrated in retail stores sampled in this study, is a viable strategy to meet the health guideline. Total volatile compound were present in retail stores at low concentrations well below health guidelines suggested by Molhave (1700microg /m 2) and Bridges (1000 microg /m2). Based on these results and through mass--balance modeling, different ventilation rate reduction scenarios were proposed, and for these scenarios the differences in energy consumption were estimated. Findings of all phases of this desertion have contributed to understanding (a) the trade-off between energy savings and ventilation rates that do not compromise indoor air quality, and (b) the trade-off between energy savings and resets of indoor air temperature that do not compromise thermal comfort. Two models for retail stores were built and calibrated and validated against actual utility bills. Energy simulation results indicated that by lowering the ventilation rates from measured and minimum references would reduce natural gas energy use by estimated values of 6% to 19%. Also, this study found that the electrical cooling energy consumption was not significantly sensitive to different ventilation rates. However, increasing indoor air temperature by 3°C in summer had a significant effect on the energy savings. In winter, both energy savings strategies, ventilation reduction and decrease in set points, had a significant effect on natural gas consumption. Specially, when the indoor air temperature 21°C was decreased to 19.4°C with the same amount of ventilation rate of Molhaves guideline for both cases. Interestingly, the temperature of 23.8°C (75°F), which is the lowest value of ASHRAE 55 thermal comfort for sedentary people (cashiers) and the highest value for thermal comfort adjustments due to activity level (customers and workers) that are calculated by using empirical equation, was the optimum temperature for sedentary and active people in Retail store buildings.
Zimmer, M B; Milsom, W K
2001-01-01
To determine whether metabolic rate is suppressed in a temperature-independent fashion in the golden-mantled ground squirrel during steady state hibernation, we measured body temperature and metabolic rate in ground squirrels during hibernation at different T(a)'s. In addition, we attempted to determine whether heart rate, ventilation rate, and breathing patterns changed as a function of body temperature or metabolic rate. We found that metabolic rate changed with T(a) as it was raised from 5 degrees to 14 degrees C, which supports the theory that different species sustain falls in metabolic rate during hibernation in different ways. Heart rate and breathing pattern also changed with changing T(a), while breathing frequency did not. That the total breathing frequency did not correlate closely with oxygen consumption or body temperature, while the breathing pattern did, raises important questions regarding the mechanisms controlling ventilation during hibernation.
Hawkins, Michelle G; Malka, Shachar; Pascoe, Peter J; Solano, Adrian M; Kass, Philip H; Ohmura, Hajime; Jones, James H
2013-01-01
To evaluate the effects of dorsal versus lateral recumbency on the cardiopulmonary system during isoflurane anesthesia in red-tailed hawks (Buteo jamaicensis). 6 adult 1.1- to 1.6-kg red-tailed hawks. A randomized, crossover study was used to evaluate changes in respiratory rate, tidal volume, minute ventilation, heart rate, mean arterial and indirect blood pressures, and end-tidal Pco(2) measured every 5 minutes plus Paco(2) and Pao(2) and arterial pH measured every 15 minutes throughout a 75-minute study period. Respiratory rate was higher, tidal volume lower, and minute ventilation not different in lateral versus dorsal recumbency. Position did not affect heart rate, mean arterial blood pressure, or indirect blood pressure, although heart rate decreased during the anesthetic period. Birds hypoventilated in both positions and Paco(2) differed with time and position × time interaction. The Petco(2) position × time interaction was significant and Petco(2) was a mean of 7 Torr higher than Paco(2). The Paco(2) in dorsal recumbency was a mean of 32 Torr higher than in lateral recumbency. Birds in both positions developed respiratory acidosis. Differences in tidal volume with similar minute ventilation suggested red-tailed hawks in dorsal recumbency might have lower dead space ventilation. Despite similar minute ventilation in both positions, birds in dorsal recumbency hypoventilated more yet maintained higher Pao(2), suggesting parabronchial ventilatory or pulmonary blood flow distribution changes with position. The results refute the hypothesis that dorsal recumbency compromises ventilation and O(2) transport more than lateral recumbency in red-tailed hawks.
Automatic control of pressure support for ventilator weaning in surgical intensive care patients.
Schädler, Dirk; Engel, Christoph; Elke, Gunnar; Pulletz, Sven; Haake, Nils; Frerichs, Inéz; Zick, Günther; Scholz, Jens; Weiler, Norbert
2012-03-15
Despite its ability to reduce overall ventilation time, protocol-guided weaning from mechanical ventilation is not routinely used in daily clinical practice. Clinical implementation of weaning protocols could be facilitated by integration of knowledge-based, closed-loop controlled protocols into respirators. To determine whether automated weaning decreases overall ventilation time compared with weaning based on a standardized written protocol in an unselected surgical patient population. In this prospective controlled trial patients ventilated for longer than 9 hours were randomly allocated to receive either weaning with automatic control of pressure support ventilation (automated-weaning group) or weaning based on a standardized written protocol (control group) using the same ventilation mode. The primary end point of the study was overall ventilation time. Overall ventilation time (median [25th and 75th percentile]) did not significantly differ between the automated-weaning (31 [19-101] h; n = 150) and control groups (39 [20-118] h; n = 150; P = 0.178). Patients who underwent cardiac surgery (n = 132) exhibited significantly shorter overall ventilation times in the automated-weaning (24 [18-57] h) than in the control group (35 [20-93] h; P = 0.035). The automated-weaning group exhibited shorter ventilation times until the first spontaneous breathing trial (1 [0-15] vs. 9 [1-51] h; P = 0.001) and a trend toward fewer tracheostomies (17 vs. 28; P = 0.075). Overall ventilation times did not significantly differ between weaning using automatic control of pressure support ventilation and weaning based on a standardized written protocol. Patients after cardiac surgery may benefit from automated weaning. Implementation of additional control variables besides the level of pressure support may further improve automated-weaning systems. Clinical trial registered with www.clinicaltrials.gov (NCT 00445289).
White, Duvel W.; Feigley, Charles E.; McKeown, Robert E.; Hout, Joseph J.; Hebert, James R.
2015-01-01
Background Acute respiratory infections (ARIs) are the leading cause of acute morbidity and lost work time in the United States. Few studies have looked at building design and transmission of ARIs. Objectives This study explores the association of ventilation design, room occupancy numbers, and training week with ARI rates in Army Basic Combat Training barracks. Methods This observational study captured the overall incidence of ARI in a cohort of 16,258 individuals attending basic combat training at Fort Jackson, South Carolina. Results ARI risk was higher among trainees living in the 60-person room barracks compared with those living in 8-person rooms, which increased rapidly for the first few weeks of training and then declined to baseline. Conclusions Findings support direct contact as primary ARI transmission mode in this study population based on observed lower ARI risk in smaller room barracks and similar risk in large room barracks despite heating, ventilation, and air conditioning system variability. PMID:21882781
Wang, W-F; Liu, S; Xu, B
2017-03-01
To investigate the protective effects and mechanism of ketamine on acute lung injury induced by mechanical ventilation. 63 patients with acute lung injury caused by mechanical ventilation in our hospital between June 2014 and May 2015 were chosen and divided into three groups: group A, B, and C. Group A (20 cases) received conventional treatment. Group B (21 cases) was treated with propofol and group C (22 cases) with ketamine. The ventilator application time, the success rate of weaning, the mortality rate, inflammation index (IL-1, Caspase-1, and NF-κB), pulmonary function index and oxygen saturation were compared. The ventilator application time and the mortality rate of group B and group C were significantly (p < 0.05) lower than those of group A. The success rate of weaning of groups B and C was higher (p < 0.05) than that of group A. There was no difference between groups B and C. After intervention, the levels of PaO2 and SpO2 in the three groups increased, while the level of PaCO2decreased with better improvement in group B and group C than in group A (p < 0.05), groups B and C being similar (p > 0.05). After the intervention, the levels of FEV1, FEV1/FVC, FVC and PEER in the three groups increased, but more remarkably in group B and group C (p < 0.05), in which there was no difference. After the intervention, the levels of IL-1β, Caspase-1, and NF-κB in the three groups decreased with the levels of group C obviously lower (p < 0.05) than those of groups B and A, the highest. Both ketamine and propofol can improve the blood gas and pulmonary function index of patients with acute lung injury caused by mechanical ventilation. They shorten the application time of ventilator, improve the success rate of weaning and reduce the mortality rate which is probably related to the reduction of the degree of inflammatory reaction. Ketamine is more effective in reducing inflammatory factors including IL-1β, Caspase-1, and NF-κB than propofol.
Cozza, Izabela Campos; Zanetta, Dirce Maria Trevisan; Fernandes, Frederico Leon Arrabal; da Rocha, Francisco Marcelo Monteiro; de Andre, Paulo Afonso; Garcia, Maria Lúcia Bueno; Paceli, Renato Batista; Prado, Gustavo Faibischew; Terra-Filho, Mario; do Nascimento Saldiva, Paulo Hilário; de Paula Santos, Ubiratan
2015-07-01
The effects of air pollution on health are associated with the amount of pollutants inhaled which depends on the environmental concentration and the inhaled air volume. It has not been clear whether statistical models of the relationship between heart rate and ventilation obtained using laboratory cardiopulmonary exercise test (CPET) can be applied to an external group to estimate ventilation. To develop and evaluate a model to estimate respiratory ventilation based on heart rate for inhaled load of pollutant assessment in field studies. Sixty non-smoking men; 43 public street workers (public street group) and 17 employees of the Forest Institute (park group) performed a maximum cardiopulmonary exercise test (CPET). Regression equation models were constructed with the heart rate and natural logarithmic of minute ventilation data obtained on CPET. Ten individuals were chosen randomly (public street group) and were used for external validation of the models (test group). All subjects also underwent heart rate register, and particulate matter (PM2.5) monitoring for a 24-hour period. For the public street group, the median difference between estimated and observed data was 0.5 (CI 95% -0.2 to 1.4) l/min and for the park group was 0.2 (CI 95% -0.2 to 1.2) l/min. In the test group, estimated values were smaller than the ones observed in the CPET, with a median difference of -2.4 (CI 95% -4.2 to -1.8) l/min. The mixed model estimated values suggest that this model is suitable for situations in which heart rate is around 120-140bpm. The mixed effect model is suitable for ventilation estimate, with good accuracy when applied to homogeneous groups, suggesting that, in this case, the model could be used in field studies to estimate ventilation. A small but significant difference in the median of external validation estimates was observed, suggesting that the applicability of the model to external groups needs further evaluation. Copyright © 2015 Elsevier B.V. All rights reserved.
Nyhan, Marguerite; McNabola, Aonghus; Misstear, Bruce
2014-01-15
Exposure to airborne particulate matter (PM) has been linked to cardiovascular morbidity and mortality. Heart rate variability (HRV) is a measure of the change in cardiac autonomic function, and consistent links between PM exposure and decreased HRV have been documented in studies. This study quantitatively assesses the acute relative variation of HRV with predicted PM dose in the lungs of commuters. Personal PM exposure, HR and HRV were monitored in 32 young healthy cyclists, pedestrians, bus and train passengers. Inhaled and lung deposited PM doses were determined using a numerical model of the human respiratory tract which accounted for varying ventilation rates between subjects and during commutes. Linear mixed models were used to examine air pollution dose and HRV response relationships in 122 commutes sampled. Elevated PM2.5 and PM10 inhaled and lung deposited doses were significantly (p<0.05) associated with decreased HRV indices. Percent declines in SDNN (standard deviation of normal RR intervals) relative to resting, due to an inter-quartile range increase in PM10 lung deposited dose were stronger in cyclists (-6.4%, 95% CI: -11.7, -1.3) and pedestrians (-5.8%, 95% CI: -11.3, -0.5), in comparison to bus (-3.2%, 95% CI: -6.4, -0.1) and train (-1.8%, -7.5, 3.8) passengers. A similar trend was observed in the case of PM2.5 lung deposited dose and results for rMSSD (the square root of the squared differences of successive normal RR intervals) followed similar trends to SDNN. Inhaled and lung deposited doses accounting for varying ventilation rates between modes, individuals and during commutes have been neglected in other studies relating PM to HRV. The findings here indicate that exercise whilst commuting has an influence on inhaled PM and PM lung deposited dose, and these were significantly associated with acute declines in HRV, especially in pedestrians and cyclists. © 2013.
McMurphy, Rose M; Young, Lesley E; Marlin, David J; Walsh, Karen
2002-12-01
To compare cardiopulmonary responses during anesthesia maintained with halothane and responses during anesthesia maintained by use of a total intravenous anesthetic (TIVA) regimen in horses. 7 healthy adult horses (1 female, 6 geldings). Each horse was anesthetized twice. Romifidine was administered IV, and anesthesia was induced by IV administration of ketamine. Anesthesia was maintained for 75 minutes by administration of halothane (HA) or IV infusion of romifidine, guaifenesin, and ketamine (TIVA). The order for TIVA or HA was randomized. Cardiopulmonary variables were measured 40, 60, and 75 minutes after the start of HA orTIVA. Systolic, diastolic, and mean carotid arterial pressures, velocity time integral, and peak acceleration of aortic blood flow were greater, and systolic, diastolic, and mean pulmonary arterial pressure were lower at all time points for TIVA than for HA. Pre-ejection period was shorter and ejection time was longer for TIVA than for HA. Heart rate was greater for HA at 60 minutes. Minute ventilation and alveolar ventilation were greater and inspiratory time was longer for TIVA than for HA at 75 minutes. The PaCO2 was higher at 60 and 75 minutes for HA than forTIVA. Horses receiving a constant-rate infusion of romifidine, guaifenesin, and ketamine maintained higher arterial blood pressures than when they were administered HA. There was some indication that left ventricular function may be better during TIVA, but influences of preload and afterload on measured variables could account for some of these differences.
Arctic Sea Ice, Eurasia Snow, and Extreme Winter Haze in China
NASA Astrophysics Data System (ADS)
Zou, Y.; Wang, Y.; Xie, Z.; Zhang, Y.; Koo, J. H.
2017-12-01
Eastern China is experiencing more severe haze pollution in winter during recent years. Though the environmental deterioration in this region is usually attributed to the high intensity of anthropogenic emissions and large contributions from secondary aerosol formation, the impact of climate variability is also indispensable given its significant influence on regional weather systems and pollution ventilation. Here we analyzed the air quality related winter meteorological conditions over Eastern China in the last four decades and showed a worsening trend in poor regional air pollutant ventilation. Such variations increased the probability of extreme air pollution events, which is in good agreement with aerosol observations of recent years. We further identified the key circulation pattern that is conducive to the weakening ventilation and investigated the relationship between synoptic circulation changes and multiple climate forcing variables. Both statistical analysis and numerical sensitivity experiments suggested that the poor ventilation condition is linked to boreal cryosphere changes including Arctic sea ice in preceding autumn and Eurasia snowfall in earlier winter. We conducted comprehensive dynamic diagnosis and proposed a physical mechanism to explain the observed and simulated circulation changes. At last, we examined future projections of winter extreme stagnation events based on the CMIP5 projection data.
Information flow to assess cardiorespiratory interactions in patients on weaning trials.
Vallverdú, M; Tibaduisa, O; Clariá, F; Hoyer, D; Giraldo, B; Benito, S; Caminal, P
2006-01-01
Nonlinear processes of the autonomic nervous system (ANS) can produce breath-to-breath variability in the pattern of breathing. In order to provide assess to these nonlinear processes, nonlinear statistical dependencies between heart rate variability and respiratory pattern variability are analyzed. In this way, auto-mutual information and cross-mutual information concepts are applied. This information flow analysis is presented as a short-term non linear analysis method to investigate the information flow interactions in patients on weaning trials. 78 patients from mechanical ventilation were studied: Group A of 28 patients that failed to maintain spontaneous breathing and were reconnected; Group B of 50 patients with successful trials. The results show lower complexity with an increase of information flow in group A than in group B. Furthermore, a more (weakly) coupled nonlinear oscillator behavior is observed in the series of group A than in B.
Does oral alprazolam affect ventilation? A randomised, double-blind, placebo-controlled trial.
Carraro, G E; Russi, E W; Buechi, S; Bloch, Konrad E
2009-05-01
The respiratory effects of benzodiazepines have been controversial. This investigation aimed to study the effects of oral alprazolam on ventilation. In a randomised, double-blind cross-over protocol, 20 healthy men ingested 1 mg of alprazolam or placebo in random order, 1 week apart. Ventilation was unobtrusively monitored by inductance plethysmography along with end-tidal PCO(2) and pulse oximetry 60-160 min after drug intake. Subjects were encouraged to keep their eyes open. Mean +/- SD minute ventilation 120 min after alprazolam and placebo was similar (6.21 +/- 0.71 vs 6.41 +/- 1.12 L/min, P = NS). End-tidal PCO(2) and oxygen saturation did also not differ between treatments. However, coefficients of variation of minute ventilation after alprazolam exceeded those after placebo (43 +/- 23% vs 31 +/- 13%, P < 0.05). More encouragements to keep the eyes open were required after alprazolam than after placebo (5.2 +/- 5.7 vs 1.3 +/- 2.3 calls, P < 0.05). In a multiple regression analysis, higher coefficients of variation of minute ventilation after alprazolam were related to a greater number of calls. Oral alprazolam in a mildly sedative dose has no clinically relevant effect on ventilation in healthy, awake men. The increased variability of ventilation on alprazolam seems related to vigilance fluctuations rather than to a direct drug effect on ventilation.
Airway pressure release ventilation: what do we know?
Daoud, Ehab G; Farag, Hany L; Chatburn, Robert L
2012-02-01
Airway pressure release ventilation (APRV) is inverse ratio, pressure controlled, intermittent mandatory ventilation with unrestricted spontaneous breathing. It is based on the principle of open lung approach. It has many purported advantages over conventional ventilation, including alveolar recruitment, improved oxygenation, preservation of spontaneous breathing, improved hemodynamics, and potential lung-protective effects. It has many claimed disadvantages related to risks of volutrauma, increased work of breathing, and increased energy expenditure related to spontaneous breathing. APRV is used mainly as a rescue therapy for the difficult to oxygenate patients with acute respiratory distress syndrome (ARDS). There is confusion regarding this mode of ventilation, due to the different terminology used in the literature. APRV settings include the "P high," "T high," "P low," and "T low". Physicians and respiratory therapists should be aware of the different ways and the rationales for setting these variables on the ventilators. Also, they should be familiar with the differences between APRV, biphasic positive airway pressure (BIPAP), and other conventional and nonconventional modes of ventilation. There is no solid proof that APRV improves mortality; however, there are ongoing studies that may reveal further information about this mode of ventilation. This paper reviews the different methods proposed for APRV settings, and summarizes the different studies comparing APRV and BIPAP, and the potential benefits and pitfalls for APRV.
Iannucci, Glen J; Oster, Matthew E; Chanani, Nikhil K; Gillespie, Scott E; McCracken, Courtney E; Kanter, Kirk R; Mahle, William T
2014-03-01
Many cardiac ICUs have instituted 24/7 attending physician in-house coverage, which theoretically may allow for more expeditious weaning from ventilation and extubation. We aimed to determine whether this staffing strategy impacts rates of nighttime extubation and duration of mechanical ventilation. National data were obtained from the Virtual PICU System database for all patients admitted to the cardiac ICU following congenital heart surgery in 2011 who required postoperative mechanical ventilation. Contemporaneous data from our local institution were collected in addition to the Virtual PICU System data. The combined dataset (n = 2,429) was divided based on the type of nighttime staffing model in order to compare rates of nighttime extubation and duration of mechanical ventilation between units that used an in-house attending staffing strategy and those that employed nighttime residents, fellows, or midlevel providers only. Institutions that currently use 24/7 in-house attending coverage did not demonstrate statistically significant differences in rates of nighttime extubation or the duration of mechanical ventilation in comparison to units without in-house attendings. Younger patients cared for in non-in-house attending units were more likely to require reintubation. Pediatric patients who have undergone congenital heart surgery can be safely and effectively extubated without the routine presence of an attending physician. The utilization of nighttime in-house attending coverage does not appear to have significant benefits on the rate of nighttime extubation and may not reduce the duration of mechanical ventilation in units that already use in-house residents, fellows, or other midlevel providers.
2004-11-01
variation in ventilation rates over time and the distribution of ventilation air within a building, and to estimate the impact of envelope air ... tightening efforts on infiltration rates. • It may be used to determine the indoor air quality performance of a building before construction, and to
Education on invasive mechanical ventilation involving intensive care nurses: a systematic review.
Guilhermino, Michelle C; Inder, Kerry J; Sundin, Deborah
2018-03-26
Intensive care unit nurses are critical for managing mechanical ventilation. Continuing education is essential in building and maintaining nurses' knowledge and skills, potentially improving patient outcomes. The aim of this study was to determine whether continuing education programmes on invasive mechanical ventilation involving intensive care unit nurses are effective in improving patient outcomes. Five electronic databases were searched from 2001 to 2016 using keywords such as mechanical ventilation, nursing and education. Inclusion criteria were invasive mechanical ventilation continuing education programmes that involved nurses and measured patient outcomes. Primary outcomes were intensive care unit mortality and in-hospital mortality. Secondary outcomes included hospital and intensive care unit length of stay, length of intubation, failed weaning trials, re-intubation incidence, ventilation-associated pneumonia rate and lung-protective ventilator strategies. Studies were excluded if they excluded nurses, patients were ventilated for less than 24 h, the education content focused on protocol implementation or oral care exclusively or the outcomes were participant satisfaction. Quality was assessed by two reviewers using an education intervention critical appraisal worksheet and a risk of bias assessment tool. Data were extracted independently by two reviewers and analysed narratively due to heterogeneity. Twelve studies met the inclusion criteria for full review: 11 pre- and post-intervention observational and 1 quasi-experimental design. Studies reported statistically significant reductions in hospital length of stay, length of intubation, ventilator-associated pneumonia rates, failed weaning trials and improvements in lung-protective ventilation compliance. Non-statistically significant results were reported for in-hospital and intensive care unit mortality, re-intubation and intensive care unit length of stay. Limited evidence of the effectiveness of continuing education programmes on mechanical ventilation involving nurses in improving patient outcomes exists. Comprehensive continuing education is required. Well-designed trials are required to confirm that comprehensive continuing education involving intensive care nurses about mechanical ventilation improves patient outcomes. © 2018 British Association of Critical Care Nurses.
Health and Wellbeing of Occupants in Highly Energy Efficient Buildings: A Field Study.
Wallner, Peter; Tappler, Peter; Munoz, Ute; Damberger, Bernhard; Wanka, Anna; Kundi, Michael; Hutter, Hans-Peter
2017-03-19
Passive houses and other highly energy-efficient buildings need mechanical ventilation. However, ventilation systems in such houses are regarded with a certain degree of skepticism by parts of the public due to alleged negative health effects. Within a quasi-experimental field study, we investigated if occupants of two types of buildings (mechanical vs. natural ventilation) experience different health, wellbeing and housing satisfaction outcomes and if associations with indoor air quality exist. We investigated 123 modern homes (test group: with mechanical ventilation; control group: naturally ventilated) built in the years 2010 to 2012 in the same geographic area and price range. Interviews of occupants based on standardized questionnaires and measurements of indoor air quality parameters were conducted twice (three months after moving in and one year later). In total, 575 interviews were performed (respondents' mean age 37.9 ± 9 years in the test group, 37.7 ± 9 years in the control group). Occupants of the test group rated their overall health status and that of their children not significantly higher than occupants of the control group at both time points. Adult occupants of the test group reported dry eyes statistically significantly more frequently compared to the control group (19.4% vs. 12.5%). Inhabitants of energy-efficient, mechanically ventilated homes rated the quality of indoor air and climate significantly higher. Self-reported health improved more frequently in the mechanically ventilated new homes ( p = 0.005). Almost no other significant differences between housing types and measuring time points were observed concerning health and wellbeing or housing satisfaction. Associations between vegetative symptoms (dizziness, nausea, headaches) and formaldehyde concentrations as well as between CO₂ levels and perceived stale air were observed. However, both associations were independent of the type of ventilation. In summary, occupants of the mechanically ventilated homes rated their health status slightly higher and their health improved significantly more frequently than in occupants of the control group. As humidity in homes with mechanical ventilation was lower, it seems plausible that the inhabitants reported dry eyes more frequently.
Impact of whole-body rehabilitation in patients receiving chronic mechanical ventilation.
Martin, Ubaldo J; Hincapie, Luis; Nimchuk, Mark; Gaughan, John; Criner, Gerard J
2005-10-01
To evaluate the prevalence and magnitude of weakness in patients receiving chronic mechanical ventilation and the impact of providing aggressive whole-body rehabilitation on conventional weaning variables, muscle strength, and overall functional status. Retrospective analysis of 49 consecutive patients. Multidisciplinary ventilatory rehabilitation unit in an academic medical center. Forty-nine consecutive chronic ventilator-dependent patients referred to a tertiary care hospital ventilator rehabilitation unit. None. Patients were 58 +/- 7 yrs old with multiple etiologies for respiratory failure. On admission, all patients were bedridden and had severe weakness of upper and lower extremities measured by a 5-point muscle strength score and a 7-point Functional Independence Measurement. Postrehabilitation, patients had increases in upper and lower extremity strength (p < .05) and were able to stand and ambulate. All weaned from mechanical ventilation, but three required subsequent intermittent support. Six patients died before hospital discharge. Upper extremity strength on admission inversely correlated with time to wean from mechanical ventilation (R = .72, p < .001). : Patients receiving chronic ventilation are weak and deconditioned but respond to aggressive whole-body and respiratory muscle training with an improvement in strength, weaning outcome, and functional status. Whole-body rehabilitation should be considered a significant component of their therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
"9One method of code-compliance for crawlspaces is to seal and insulate the crawlspace, rather than venting to the outdoors. However, codes require mechanical ventilation; either via conditioned supply air from the HVAC system, or a continuous exhaust ventilation strategy. As the CARB's building partner, Ithaca Neighborhood Housing Services, intended to use the unvented crawlspace in a recent development, CARB was interested in investigating a hybrid ventilation method that includes the exhaust air from the crawlspace as a portion of an ASHRAE 62.2 compliant whole-house ventilation strategy. This hybrid ventilation method was evaluated through a series of long-term monitoring tests thatmore » observed temperature, humidity, and pressure conditions through the home and crawlspace. Additionally, CARB worked with NREL to perform multi-point tracer gas testing on six separate ventilation strategies - varying portions of 62.2 required flow supplied by the crawlspace fan and an upstairs bathroom fan. The intent of the tracer gas testing was to identify effective Reciprocal Age of Air (RAoA), which is equivalent to the air change rate in well-mixed zones, for each strategy while characterizing localized infiltration rates in several areas of the home.« less
Generation rate of carbon monoxide from CO2 arc welding.
Ojima, Jun
2013-01-01
CO poisoning has been a serious industrial hazard in Japanese workplaces. Although incomplete combustion is the major cause of CO generation, there is a risk of CO poisoning during some welding operations. The aim of the present study was to evaluate the generation rate of CO from CO2 arc welding under controlled laboratory conditions and estimate the ventilation requirements for the prevention of CO poisoning. Bead on plate welding was carried out with an automatic welding robot on a rolled steel base metal under several conditions. The concentration of emitted CO from the welding was measured by a real-time CO monitor in a well-ventilated laboratory that was free from ambient CO contamination. The generation rate of CO was obtained from the three measurements-the flow rate of the welding exhaust gas, CO concentration in the exhaust gas and the arcing time. Then the ventilation requirement to prevent CO poisoning was calculated. The generation rate of CO was found to be 386-883 ml/min with a solid wire and 331-1,293 ml/min with a flux cored wire respectively. It was found that the CO concentration in a room would be maintained theoretically below the OSHA PEL (50 ppm) providing the ventilation rate in the room was 6.6-25.9 m3/min. The actual ventilation requirement was then estimated to be 6.6-259 m3/min considering incomplete mixing. In order to prevent CO poisoning, some countermeasures against gaseous emission as well as welding fumes should be taken eagerly.
Actual performance of mechanical ventilators in ICU: a multicentric quality control study.
Govoni, Leonardo; Dellaca', Raffaele L; Peñuelas, Oscar; Bellani, Giacomo; Artigas, Antonio; Ferrer, Miquel; Navajas, Daniel; Pedotti, Antonio; Farré, Ramon
2012-01-01
Even if the performance of a given ventilator has been evaluated in the laboratory under very well controlled conditions, inappropriate maintenance and lack of long-term stability and accuracy of the ventilator sensors may lead to ventilation errors in actual clinical practice. The aim of this study was to evaluate the actual performances of ventilators during clinical routines. A resistance (7.69 cmH(2)O/L/s) - elastance (100 mL/cmH(2)O) test lung equipped with pressure, flow, and oxygen concentration sensors was connected to the Y-piece of all the mechanical ventilators available for patients in four intensive care units (ICUs; n = 66). Ventilators were set to volume-controlled ventilation with tidal volume = 600 mL, respiratory rate = 20 breaths/minute, positive end-expiratory pressure (PEEP) = 8 cmH(2)O, and oxygen fraction = 0.5. The signals from the sensors were recorded to compute the ventilation parameters. The average ± standard deviation and range (min-max) of the ventilatory parameters were the following: inspired tidal volume = 607 ± 36 (530-723) mL, expired tidal volume = 608 ± 36 (530-728) mL, peak pressure = 20.8 ± 2.3 (17.2-25.9) cmH(2)O, respiratory rate = 20.09 ± 0.35 (19.5-21.6) breaths/minute, PEEP = 8.43 ± 0.57 (7.26-10.8) cmH(2)O, oxygen fraction = 0.49 ± 0.014 (0.41-0.53). The more error-prone parameters were the ones related to the measure of flow. In several cases, the actual delivered mechanical ventilation was considerably different from the set one, suggesting the need for improving quality control procedures for these machines.
Analysis on ventilation pressure of fire area in longitudinal ventilation of underground tunnel
NASA Astrophysics Data System (ADS)
Li, Jiaxin; Li, Yanfeng; Feng, Xiao; Li, Junmei
2018-03-01
In order to solve the problem of ventilation pressure loss in the fire area under the fire condition, the wind pressure loss model of the fire area is established based on the thermodynamic equilibrium relation. The semi-empirical calculation formula is obtained by using the model experiment and CFD simulation. The validity of the formula is verified. The results show that the ventilation pressure loss in the fire zone is proportional to the convective heat release rate at the critical velocity, which is inversely proportional to the upstream ventilation velocity and the tunnel cross-sectional area. The proposed formula is consistent with the law of the tunnel fire test fitting formula that results are close, in contrast, the advantage lies in a clear theoretical basis and ventilation velocity values. The resistance of road tunnel ventilation system is calculated accurately and reliably, and then an effective emergency ventilation operation program is developed. It is necessary to consider the fire zone ventilation pressure loss. The proposed ventilation pressure loss formula can be used for design calculation after thorough verification.
Pretest Predictions for Ventilation Tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Y. Sun; H. Yang; H.N. Kalia
The objective of this calculation is to predict the temperatures of the ventilating air, waste package surface, concrete pipe walls, and insulation that will be developed during the ventilation tests involving various test conditions. The results will be used as input to the following three areas: (1) Decisions regarding testing set-up and performance. (2) Assessing how best to scale the test phenomena measured. (3) Validating numerical approach for modeling continuous ventilation. The scope of the calculation is to identify the physical mechanisms and parameters related to thermal response in the ventilation tests, and develop and describe numerical methods that canmore » be used to calculate the effects of continuous ventilation. Sensitivity studies to assess the impact of variation of linear power densities (linear heat loads) and ventilation air flow rates are included. The calculation is limited to thermal effect only.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Rudd and D. Bergey
Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, andmore » filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs.« less
Kuwabara, Kazuaki; Matsuda, Shinya; Fushimi, Kiyohide; Ishikawa, Koichi B; Horiguchi, Hiromasa; Fujimori, Kenji
2012-01-01
Public health emergencies like earthquakes and tsunamis underscore the need for an evidence-based approach to disaster preparedness. Using the Japanese administrative database and the geographical information system (GIS), the interruption of hospital-based mechanical ventilation administration by a hypothetical disaster in three areas of the southeastern mainland (Tokai, Tonankai, and Nankai) was simulated and the repercussions on ventilator care in the prefectures adjacent to the damaged prefectures was estimated. Using the database of 2010 including 3,181,847 hospitalized patients among 952 hospitals, the maximum daily ventilator capacity in each hospital was calculated and the number of patients who were administered ventilation on October xx was counted. Using GIS and patient zip code, the straight-line distances among the damaged hospitals, the hospitals in prefectures nearest to damaged prefectures, and ventilated patients' zip codes were measured. The authors simulated that ventilated patients were transferred to the closest hospitals outside damaged prefectures. The increase in the ventilator operating rates in three areas was aggregated. One hundred twenty-four and 236 patients were administered ventilation in the damaged hospitals and in the closest hospitals outside the damaged prefectures of Tokai, 92 and 561 of Tonankai, and 35 and 85 of Nankai, respectively. The increases in the ventilator operating rates among prefectures ranged from 1.04 to 26.33-fold in Tokai; 1.03 to 1.74-fold in Tonankai, and 1.00 to 2.67-fold in Nankai. Administrative databases and GIS can contribute to evidenced-based disaster preparedness and the determination of appropriate receiving hospitals with available medical resources.
The influence of mechanical ventilation on physiological parameters in ball pythons (Python regius).
Jakobsen, Sashia L; Williams, Catherine J A; Wang, Tobias; Bertelsen, Mads F
2017-05-01
Mechanical ventilation is widely recommended for reptiles during anesthesia, and while it is well-known that their low ectothermic metabolism requires much lower ventilation than in mammals, very little is known about the influence of ventilation protocol on the recovery from anesthesia. Here, 15 ball pythons (Python regius) were induced and maintained with isoflurane for 60min at one of three ventilation protocols (30, 125, or 250mlmin -1 kg -1 body mass) while an arterial catheter was inserted, and ventilation was then continued on 100% oxygen at the specified rate until voluntary extubation. Mean arterial blood pressure and heart rate (HR) were measured, and arterial blood samples collected at 60, 80, 180min and 12 and 24h after intubation. In all three groups, there was evidence of a metabolic acidosis, and snakes maintained at 30mlmin -1 kg -1 experienced an additional respiratory acidosis, while the two other ventilation protocols resulted in normal or low arterial PCO 2 . In general, normal acid-base status was restored within 12h in all three protocols. HR increased by 143±64% during anesthesia with high mechanical ventilation (250mlmin -1 kg -1 ) in comparison with recovered values. Recovery times after mechanical ventilation at 30, 125, or 250mlmin -1 kg -1 were 289±70, 126±16, and 68±7min, respectively. Mild overventilation may result in a faster recovery, and the associated lowering of arterial PCO 2 normalised arterial pH in the face of metabolic acidosis. Copyright © 2017 Elsevier Inc. All rights reserved.
Mechanical ventilation strategies.
Keszler, Martin
2017-08-01
Although only a small proportion of full term and late preterm infants require invasive respiratory support, they are not immune from ventilator-associated lung injury. The process of lung damage from mechanical ventilation is multifactorial and cannot be linked to any single variable. Atelectrauma and volutrauma have been identified as the most important and potentially preventable elements of lung injury. Respiratory support strategies for full term and late preterm infants have not been as thoroughly studied as those for preterm infants; consequently, a strong evidence base on which to make recommendations is lacking. The choice of modalities of support and ventilation strategies should be guided by the specific underlying pathophysiologic considerations and the ventilatory approach must be individualized for each patient based on the predominant pathophysiology at the time. Copyright © 2017 Elsevier Ltd. All rights reserved.
VWPS: A Ventilator Weaning Prediction System with Artificial Intelligence
NASA Astrophysics Data System (ADS)
Chen, Austin H.; Chen, Guan-Ting
How to wean patients efficiently off mechanical ventilation continues to be a challenge for medical professionals. In this paper we have described a novel approach to the study of a ventilator weaning prediction system (VWPS). Firstly, we have developed and written three Artificial Neural Network (ANN) algorithms to predict a weaning successful rate based on the clinical data. Secondly, we have implemented two user-friendly weaning success rate prediction systems; the VWPS system and the BWAP system. Both systems could be used to help doctors objectively and effectively predict whether weaning is appropriate for patients based on the patients' clinical data. Our system utilizes the powerful processing abilities of MatLab. Thirdly, we have calculated the performance through measures such as sensitivity and accuracy for these three algorithms. The results show a very high sensitivity (around 80%) and accuracy (around 70%). To our knowledge, this is the first design approach of its kind to be used in the study of ventilator weaning success rate prediction.
Collignan, Bernard; Powaga, Emilie
2017-11-23
For a given radon potential in the ground and a given building, the parameters affecting the indoor radon activity concentration (IRnAC) are indoor depressurization of a building and its air change rate. These parameters depend mainly on the building characteristics, such as airtightness, and on the nature and performances of the ventilation system. This study involves a numerical sensitivity assessment of the indoor environmental conditions on the IRnAC in buildings. A numerical ventilation model has been adapted to take into account the effects of variations in the indoor environmental conditions (depressurization and air change rate) on the radon entry rate and on the IRnAC. In the context of the development of a policy to reduce energy consumption in a building, the results obtained showed that IRnAC could be strongly affected by variations in the air permeability of the building associated with the ventilation regime. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sayegh, Ana Luiza C.; dos Santos, Marcelo R.; de Oliveira, Patricia; Fernandes, Fábio; Rondon, Eduardo; de Souza, Francis R.; Salemi, Vera M. C.; Alves, Maria Janieire de N. N.; Mady, Charles
2017-01-01
Background Endomyocardial fibrosis (EMF) is a rare disease, characterized by diastolic dysfunction which leads to reduced peak oxygen consumption (VO2). Cardiopulmonary exercise testing (CPET) has been proved to be a fundamental tool to identify central and peripheral alterations. However, most studies prioritize peak VO2 as the main variable, leaving aside other important CPET variables that can specify the severity of the disease and guide the clinical treatment. Objective The aim of this study was to evaluate central and peripheral limitations in symptomatic patients with EMF by different CPET variables. Methods Twenty-six EMF patients (functional class III, NYHA) were compared with 15 healthy subjects (HS). Functional capacity was evaluated using CPET and diastolic and systolic functions were evaluated by echocardiography. Results Age and gender were similar between EMF patients and HS. Left ventricular ejection fraction was normal in EMF patients, but decreased compared to HS. Peak heart rate, peak workload, peak VO2, peak oxygen (O2) pulse and peak pulmonary ventilation (VE) were decreased in EMF compared to HS. Also, EMF patients showed increased Δ heart rate /Δ oxygen uptake and Δ oxygen uptake /Δ work rate compared to HS. Conclusion Determination of the aerobic capacity by noninvasive respiratory gas exchange during incremental exercise provides additional information about the exercise tolerance in patients with EMF. The analysis of different CPET variables is necessary to help us understand more about the central and peripheral alterations cause by both diastolic dysfunction and restrictive pattern. PMID:29364349
López-Jiménez, María José; Masa, Juan F; Corral, Jaime; Terán, Joaquín; Ordaz, Estrella; Troncoso, Maria F; González-Mangado, Nicolás; González, Mónica; Lopez-Martínez, Soledad; De Lucas, Pilar; Marín, José M; Martí, Sergi; Díaz-Cambriles, Trinidad; Díaz-de-Atauri, Josefa; Chiner, Eusebi; Aizpuru, Felipe; Egea, Carlos; Romero, Auxiliadora; Benítez, José M; Sánchez-Gómez, Jesús; Golpe, Rafael; Santiago-Recuerda, Ana; Gómez, Silvia; Barbe, Ferrán; Bengoa, Mónica
2016-03-01
The Pickwick project was a prospective, randomized and controlled study, which addressed the issue of obesity hypoventilation syndrome (OHS), a growing problem in developed countries. OHS patients were divided according to apnea-hypopnea index (AHI) ≥30 and <30 determined by polysomnography. The group with AHI≥30 was randomized to intervention with lifestyle changes, noninvasive ventilation (NIV) or continuous positive airway pressure (CPAP); the group with AHI<30 received NIV or lifestyle changes. The aim of the study was to evaluate the efficacy of NIV treatment, CPAP and lifestyle changes (control) in the medium and long-term management of patients with OHS. The primary variables were PaCO2 and days of hospitalization, and operating variables were the percentage of dropouts for medical reasons and mortality. Secondary medium-term objectives were: (i)to evaluate clinical-functional effectiveness on quality of life, echocardiographic and polysomnographic variables; (ii)to investigate the importance of apneic events and leptin in the pathogenesis of daytime alveolar hypoventilation and change according to the different treatments; (ii)to investigate whether metabolic, biochemical and vascular endothelial dysfunction disorders depend on the presence of apneas and hypopneasm and (iv)changes in inflammatory markers and endothelial damage according to treatment. Secondary long-term objectives were to evaluate: (i)clinical and functional effectiveness and quality of life with NIV and CPAP; (ii)changes in leptin, inflammatory markers and endothelial damage according to treatment; (iii)changes in pulmonary hypertension and other echocardiographic variables, as well as blood pressure and incidence of cardiovascular events, and (iv)dropout rate and mortality. Copyright © 2015 SEPAR. Published by Elsevier Espana. All rights reserved.
Souza, Gérson F; Moreira, Graciane L; Tufanin, Andréa; Gazzotti, Mariana R; Castro, Antonio A; Jardim, José R; Nascimento, Oliver A
2017-08-01
The Glittre activities of daily living (ADL) test is supposed to evaluate the functional capacity of COPD patients. The physiological requirements of the test and the time taken to perform it by COPD patients in different disease stages are not well known. The objective of this work was to compare the metabolic, ventilatory, and cardiac requirements and the time taken to carry out the Glittre ADL test by COPD subjects with mild, moderate, and severe disease. Spirometry, Medical Research Council questionnaire, cardiopulmonary exercise test, and 2 Glittre ADL tests were evaluated in 62 COPD subjects. Oxygen uptake (V̇ O 2 ), carbon dioxide production, pulmonary ventilation, breathing frequency, heart rate, S pO 2 , and dyspnea were analyzed before and at the end of the tests. Maximum voluntary ventilation, Glittre peak V̇ O 2 /cardiopulmonary exercise test (CPET) peak V̇ O 2 , Glittre V̇ E /maximum voluntary ventilation, and Glittre peak heart rate/CPET peak heart rate ratios were calculated to analyze their reserves. Subjects carried out the Glittre ADL test with similar absolute metabolic, ventilatory, and cardiac requirements. Ventilatory reserve decreased progressively from mild to severe COPD subjects ( P < .001 for Global Initiative for Chronic Obstructive Lung Disease [GOLD] 1 vs GOLD 2, P < .001 for GOLD 1 vs GOLD 3, and P < .001 for GOLD 2 vs GOLD 3). Severe subjects with COPD presented a significantly lower metabolic reserve than the mild and moderate subjects ( P = .006 and P = .043, respectively) and significantly lower Glittre peak heart rate/CPET peak heart rate than mild subjects ( P = .01). Time taken to carry out the Glittre ADL test was similar among the groups ( P = .82 for GOLD 1 vs GOLD 2, P = .19 for GOLD 1 vs GOLD 3, and P = .45 for GOLD 2 vs GOLD 3). As the degree of air-flow obstruction progresses, the COPD subjects present significant lower ventilatory reserve to perform the Glittre ADL test. In addition, metabolic and cardiac reserves may differentiate the severe subjects. These variables may be better measures to differentiate functional performance than Glittre ADL time. Copyright © 2017 by Daedalus Enterprises.
Lajoie, P; Aubin, D; Gingras, V; Daigneault, P; Ducharme, F; Gauvin, D; Fugler, D; Leclerc, J-M; Won, D; Courteau, M; Gingras, S; Héroux, M-È; Yang, W; Schleibinger, H
2015-12-01
A randomized controlled trial was carried out to measure the impact of an intervention on ventilation, indoor air contaminants, and asthma symptoms of children. Eighty-three asthmatic children living in low-ventilated homes were followed over 2 years. Several environmental parameters were measured during the summer, fall, and winter. The children were randomized after Year 1 (43 Intervention; 40 Control). The intervention included the installation of either a Heat Recovery Ventilator (HRV) or Energy Recovery Ventilator (ERV). During the fall and winter seasons, there was a significant increase in the mean ventilation rate in the homes of the intervention group. A statistically significant reduction in mean formaldehyde, airborne mold spores, toluene, styrene, limonene, and α-pinene concentrations was observed in the intervention group. There was no significant group difference in change in the number of days with symptoms per 14 days. However, there was a significant decrease in the proportion of children who experienced any wheezing (≥1 episode) and those with ≥4 episodes in the 12-month period in the intervention group. This study indicates that improved ventilation reduces air contaminants and may prevent wheezing. Due to lack of power, a bigger study is needed. Positive findings from this study include the fact that, upon recruitment, most of the single family homes with asthmatic children were already equipped with a mechanical ventilation system and had relatively good indoor air quality. However, the 8-h indoor guideline for formaldehyde (50 μg/m3) was frequently exceeded and the ventilation rates were low in most of the homes, even those with a ventilation system. Both ERVs and HRVs were equally effective at increasing air exchange rates above 0.30 ACH and at preventing formaldehyde concentrations from exceeding the 50 μg/m3 guideline during the fall and winter seasons. Furthermore, the ERVs were effective at preventing excessively low relative humidities in the homes. Based on observed difference of risk, intervention to increase ventilation in five sample homes and children would prevent 1 home to exceed the indoor air long-term formaldehyde guideline and prevent 1 asthmatic child experiencing at least one episode of wheezing over a year. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Nagano, Osamu; Yumoto, Tetsuya; Nishimatsu, Atsunori; Kanazawa, Shunsuke; Fujita, Takahisa; Asaba, Sunao; Yamanouchi, Hideo
2018-04-19
Bias flow (BF) is essential to maintain mean airway pressure (MAP) and to washout carbon dioxide (CO 2 ) from the oscillator circuit during high-frequency oscillatory ventilation (HFOV). If the BF rate is inadequate, substantial CO 2 rebreathing could occur and ventilation efficiency could worsen. With lower ventilation efficiency, the required stroke volume (SV) would increase in order to obtain the same alveolar ventilation with constant frequency. The aim of this study was to assess the effect of BF rate on ventilation efficiency during adult HFOV. The R100 oscillator (Metran, Japan) was connected to an original lung model internally equipped with a simulated bronchial tree. The actual SV was measured with a flow sensor placed at the Y-piece. Carbon dioxide (CO 2 ) was continuously insufflated into the lung model ([Formula: see text]CO 2 ), and the partial pressure of CO 2 (PCO 2 ) in the lung model was monitored. Alveolar ventilation ([Formula: see text]A) was estimated as [Formula: see text]CO 2 divided by the stabilized value of PCO 2 . [Formula: see text]A was evaluated by setting SV from 80 to 180 mL (10 mL increments, n = 5) at a frequency of 8 Hz, a MAP of 25 cmH 2 O, and a BF of 10, 20, 30, and 40 L/min (study 1). Ventilation efficiency was calculated as [Formula: see text]A divided by the actual minute volume. The experiment was also performed with an actual SV of 80, 100, and 120 mL and a BF from 10 to 60 L/min (10 L/min increments: study 2). Study 1: With the same setting SV, the [Formula: see text]A with a BF of 20 L/min or more was significantly higher than that with a BF of 10 L/min. Study 2: With the same actual SV, the [Formula: see text]A and the ventilation efficiency with a BF of 30 L/min or more were significantly higher than those with a BF of 10 or 20 L/min. Increasing BF up to 30 L/min or more improved ventilation efficiency in the R100 oscillator.
Isoflurane increases cardiorespiratory coordination in rats
NASA Astrophysics Data System (ADS)
Kabir, Muammar M.; Beig, Mirza I.; Nalivaiko, Eugene; Abbott, Derek; Baumert, Mathias
2008-12-01
Anesthetics such as isoflurane adversely affect heart rate. In this study we analysed the interaction between heart rhythm and respiration at different concentrations of isoflurane and ventilation rates. In two rats, the electrocardiogram (ECG) and respiratory signals were recorded under the influence of isoflurane. For the assessment of cardiorespiratory coordination, we analysed the phase locking between heart rate, computed from the R-R intervals of body surface ECG, and respiratory rate, computed from impedance changes, using Hilbert transform. The changes in heart rate, percentage of synchronization and duration of synchronized epochs at different isoflurane concentrations and ventilation rates were assessed using linear regression model. From this study it appears that the amount of phase locking between cardiac and respiratory rates increases with the increase in concentration of isoflurane. Heart rate and duration of synchronized epochs increased significantly with the increase in the level of isoflurane concentration while respiratory rate was not significantly affected. Cardiorespiratory coordination also showed a considerable increase at the ventilation rates of 50- 55 cpm in both the rats, suggesting that the phase-locking between the cardiac and respiratory oscillators can be increased by breathing at a particular respiratory frequency.
A multicenter mortality prediction model for patients receiving prolonged mechanical ventilation
Carson, Shannon S.; Kahn, Jeremy M.; Hough, Catherine L.; Seeley, Eric J.; White, Douglas B.; Douglas, Ivor S.; Cox, Christopher E.; Caldwell, Ellen; Bangdiwala, Shrikant I.; Garrett, Joanne M.; Rubenfeld, Gordon D.
2012-01-01
Objective Significant deficiencies exist in the communication of prognosis for patients requiring prolonged mechanical ventilation after acute illness, in part because of clinician uncertainty about long-term outcomes. We sought to refine a mortality prediction model for patients requiring prolonged ventilation using a multicentered study design. Design Cohort study. Setting Five geographically diverse tertiary care medical centers in the United States (California, Colorado, North Carolina, Pennsylvania, Washington). Patients Two hundred sixty adult patients who received at least 21 days of mechanical ventilation after acute illness. Interventions None. Measurements and Main Results For the probability model, we included age, platelet count, and requirement for vasopressors and/or hemodialysis, each measured on day 21 of mechanical ventilation, in a logistic regression model with 1-yr mortality as the outcome variable. We subsequently modified a simplified prognostic scoring rule (ProVent score) by categorizing the risk variables (age 18–49, 50–64, and >65 yrs; platelet count 0–150 and >150; vasopressors; hemodialysis) in another logistic regression model and assigning points to variables according to β coefficient values. Overall mortality at 1 yr was 48%. The area under the curve of the receiver operator characteristic curve for the primary ProVent probability model was 0.79 (95% confidence interval, 0.75–0.81), and the p value for the Hosmer-Lemeshow goodness-of-fit statistic was .89. The area under the curve for the categorical model was 0.77, and the p value for the goodness-of-fit statistic was .34. The area under the curve for the ProVent score was 0.76, and the p value for the Hosmer-Lemeshow goodness-of-fit statistic was .60. For the 50 patients with a ProVent score >2, only one patient was able to be discharged directly home, and 1-yr mortality was 86%. Conclusion The ProVent probability model is a simple and reproducible model that can accurately identify patients requiring prolonged mechanical ventilation who are at high risk of 1-yr mortality. PMID:22080643
Marjanović, Vesna; Novak, Vesna; Velicković, Ljubinka; Marjanović, Goran
2011-01-01
Patients with severe traumatic brain injury are at a risk of developing ventilator-associated pneumonia. The aim of this study was to describe the incidence, etiology, risk factors for development of ventilator-associated pneumonia and outcome in patients with severe traumatic brain injury. A retrospective study was done in 72 patients with severe traumatic brain injury, who required mechanical ventilation for more than 48 hours. Ventilator-associated pneumonia was found in 31 of 72 (43.06%) patients with severe traumatic brain injury. The risk factors for ventilator-associated pneumonia were: prolonged mechanical ventilation (12.42 vs 4.34 days, p < 0.001), longer stay at intensive care unit (17 vs 5 days, p < 0.001) and chest injury (51.61 vs 19.51%, p < 0.009) compared to patients without ventilator-associated pneumonia. The mortality rate in the patients with ventilator-associated pneumonia was higher (38.71 vs 21.95%, p = 0.12). The development of ventilator-associated pneumonia in patients with severe traumatic brain injury led to the increased morbidity due to the prolonged mechanical ventilation, longer stay at intensive care unit and chest injury, but had no effect on mortality.
Non stationary analysis of heart rate variability during the obstructive sleep apnea.
Méndez, M O; Bianchi, A M; Cerutti, S
2004-01-01
Characteristic fluctuations of the heart rate are found during obstructive sleep apnea (OSA), bradycardia in apneonic phase and tachycardia at the recovery of ventilation. In order to assess its autonomic response, in this study, the time-frequency distribution of Born-Jordan and evolutive Poincare plots are used. From Physionet was taken a database with records of ECG and respiratory signals. During the OSA all spectral indexes presented oscillations correspondent to the changes between brady and tachycardia of the RR intervals as well as greater values than during control epochs. Born-Jordan distribution and evolutive Poincare plots could help to characterize and develop an index for the evaluation of OSA. Very low frequency could also be a good index of OSA.
ERIC Educational Resources Information Center
Butcher, Samuel S.; And Others
1985-01-01
Part I of this paper (SE 538 295) described a simple model for estimating laboratory concentrations of gas phase pollutants. In this part, the measurement of ventilation rates and applications of the model are discussed. The model can provide a useful starting point in planning for safer instructional laboratories. (JN)
Aghaie, Bahman; Rejeh, Nahid; Heravi-Karimooi, Majideh; Ebadi, Abbas; Moradian, Seyed Tayeb; Vaismoradi, Mojtaba; Jasper, Melanie
2014-04-01
Weaning from mechanical ventilation is a frequent nursing activity in critical care. Nature-based sound as a non-pharmacological and nursing intervention effective in other contexts may be an efficient approach to alleviating anxiety, agitation and adverse effects of sedative medication in patients undergoing weaning from mechanical ventilation. This study identified the effect of nature-based sound therapy on agitation and anxiety on coronary artery bypass graft patients during weaning from mechanical ventilation. A randomised clinical trial design was used. 120 coronary artery bypass graft patients aged 45-65 years undergoing weaning from mechanical ventilation were randomly assigned to intervention and control groups. Patients in the intervention group listened to nature-based sounds through headphones; the control group had headphones with no sound. Haemodynamic variables, anxiety levels and agitation were assessed using the Faces Anxiety Scale and Richmond Agitation Sedation Scale, respectively. Patients in both groups had vital signs recorded after the first trigger, at 20 min intervals throughout the procedure, immediately after the procedure, 20 min after extubation, and 30 min after extubation. Data were collected over 5 months from December 2012 to April 2013. The intervention group had significantly lower anxiety and agitation levels than the control group. Regarding haemodynamic variables, a significant time trend and interaction was reported between time and group (p<0.001). A significant difference was also found between the anxiety (p<0.002) and agitation (p<0.001) scores in two groups. Nature-based sound can provide an effective method of decreasing potential adverse haemodynamic responses arising from anxiety and agitation in weaning from mechanical ventilation in coronary artery bypass graft patients. Nurses can incorporate this intervention as a non-pharmacological intervention into the daily care of patients undergoing weaning from mechanical ventilation in order to reduce their anxiety and agitation. Copyright © 2013 Elsevier Ltd. All rights reserved.
A tracer study of ventilation in the Japan/East Sea
NASA Astrophysics Data System (ADS)
Postlethwaite, C. F.; Rohling, E. J.; Jenkins, W. J.; Walker, C. F.
2005-06-01
During the Circulation Research in East Asian Marginal Seas (CREAMS) summer cruises in 1999, a suite of samples was collected for tracer analysis. Oxygen isotopes combined with tritium-helium ventilation timescales and noble gas measurements give unique insights into the ventilation of water masses in the Japan/East Sea (JES). In particular, noble gases and oxygen isotopes are indicators of brine rejection, which may assist in explaining the recent changes observed in the ventilation of the JES. Oxygen isotope data presented here indicate that both thermally driven convection and brine rejection have played significant roles in deep-water formation but that brine rejection is unlikely to be a significant contributor at the moment. A 6-box ventilation model of the JES, calibrated with tritium and helium-3 measurements, performed better when a significant decrease of dense-water formation rates in the mid-1960s was incorporated. However, the model calculations suggest that Japan Sea Intermediate Water formation is still occurring. Subduction of sea-ice melt water may be a significant ventilation mechanism for this water mass, based on an argon saturation minimum at the recently ventilated salinity minimum in the northwestern sector of the JES. The salinity and oxygen isotope budgets imply a potential bottom-water formation rate of 3.97±0.89×10 12 m 3 yr -1 due to brine rejection, which could account for a time averaged fraction of between 25% and 35% of the ventilation of subsurface water formation in the JES.
Schoenfeld, Andrew J; Belmont, Philip J; See, Aaron A; Bader, Julia O; Bono, Christopher M
2013-12-01
Predictors of complications and mortality after spine trauma are underexplored. At present, no study exists capable of predicting the impact of demographic factors, injury-specific predictors, race, ethnicity, and insurance status on morbidity and mortality after spine trauma. This study endeavored to describe the impact of patient demographics, comorbidities, injury-specific factors, race/ethnicity, and insurance status on outcomes after spinal trauma using the National Sample Program (NSP) of the National Trauma Data Bank (NTDB). The weighted sample of 75,351 incidents of spine trauma in the NTDB was used to develop a predictive model for important factors associated with mortality, postinjury complications, length of hospital stay, intensive care unit (ICU) days, and time on a ventilator. A weighted sample of 75,351 incidents of spine trauma as contained in the NTDB. Mortality, postinjury complications, length of hospital stay, ICU days, and time on a ventilator as reported in the NTDB. The 2008 NSP of the NTDB was queried to identify patients sustaining spine trauma. Patient demographics, race/ethnicity, insurance status, comorbidities, injury-specific factors, and outcomes were recorded, and a national estimate model was derived. Unadjusted differences in baseline characteristics between racial/ethnic groups and insurance status were evaluated using the t test for continuous variables and Wald chi-square analysis for categorical variables with Bonferroni correction for multiple comparisons. Weighted logistic regression was performed for categorical variables (mortality and risk of one or more complications), and weighted multiple linear regression analysis was used for continuous variables (length of hospital stay, ICU days, and ventilator time). Initial determinations were checked against a sensitivity analysis using imputed data. The weighted sample contained 75,351 incidents of spine trauma. The average age was 45.8 years. Sixty-four percent of the population was male, 9% was black/African American, 38% possessed private/commercial insurance, and 12.5% lacked insurance. The mortality rate was 6% and 16% sustained complications. Increased age, male gender, Injury Severity Score (ISS), and blood pressure at presentation were significant predictors of mortality, whereas age, male gender, other mechanism of injury, ISS, and blood pressure at presentation influenced the risk of one or more complications. Nonwhite and black/African American race increased risk of mortality, and lack of insurance increased mortality and decreased the number of hospital days, ICU days, and ventilator time. This is the first study to postulate predictors of morbidity and mortality after spinal trauma in a national model. Race/ethnicity and insurance status appear to be associated with greater risk of mortality after spine trauma. Published by Elsevier Inc.
Should Title 24 Ventilation Requirements Be Amended to include an Indoor Air Quality Procedure?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dutton, Spencer M.; Mendell, Mark J.; Chan, Wanyu R.
Minimum outdoor air ventilation rates (VRs) for buildings are specified in standards, including California?s Title 24 standards. The ASHRAE ventilation standard includes two options for mechanically-ventilated buildings ? a prescriptive ventilation rate procedure (VRP) that specifies minimum VRs that vary among occupancy classes, and a performance-based indoor air quality procedure (IAQP) that may result in lower VRs than the VRP, with associated energy savings, if IAQ meeting specified criteria can be demonstrated. The California Energy Commission has been considering the addition of an IAQP to the Title 24 standards. This paper, based on a review of prior data and newmore » analyses of the IAQP, evaluates four future options for Title 24: no IAQP; adding an alternate VRP, adding an equivalent indoor air quality procedure (EIAQP), and adding an improved ASHRAE-like IAQP. Criteria were established for selecting among options, and feedback was obtained in a workshop of stakeholders. Based on this review, the addition of an alternate VRP is recommended. This procedure would allow lower minimum VRs if a specified set of actions were taken to maintain acceptable IAQ. An alternate VRP could also be a valuable supplement to ASHRAE?s ventilation standard.« less
Transfer factor, lung volumes, resistance and ventilation distribution in healthy adults.
Verbanck, Sylvia; Van Muylem, Alain; Schuermans, Daniel; Bautmans, Ivan; Thompson, Bruce; Vincken, Walter
2016-01-01
Monitoring of chronic lung disease requires reference values of lung function indices, including putative markers of small airway function, spanning a wide age range.We measured spirometry, transfer factor of the lung for carbon monoxide (TLCO), static lung volume, resistance and ventilation distribution in a healthy population, studying at least 20 subjects per sex and per decade between the ages of 20 and 80 years.With respect to the Global Lung Function Initiative reference data, our subjects had average z-scores for forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC of -0.12, 0.04 and -0.32, respectively. Reference equations were obtained which could account for a potential dependence of index variability on age and height. This was done for (but not limited to) indices that are pertinent to asthma and chronic obstructive pulmonary disease studies: forced expired volume in 6 s, forced expiratory flow, TLCO, specific airway conductance, residual volume (RV)/total lung capacity (TLC), and ventilation heterogeneity in acinar and conductive lung zones.Deterioration in acinar ventilation heterogeneity and lung clearance index with age were more marked beyond 60 years, and conductive ventilation heterogeneity showed the greatest increase in variability with age. The most clinically relevant deviation from published reference values concerned RV/TLC values, which were considerably smaller than American Thoracic Society/European Respiratory Society-endorsed reference values. Copyright ©ERS 2016.
Burns, Karen E A; Jacob, Sonu Karottaiyamvelil; Aguirre, Valeria; Gomes, Janice; Mehta, Sangeeta; Rizvi, Leena
2016-11-01
Stakeholder engagement in research is expected to provide unique insights, make research investments more accountable and transparent, and ensure that future research is applicable to patients and family members. To inform the design of a trial of strategies for weaning from mechanical ventilation, we sought to identify preferences of patient visitors regarding outcome and treatment measures. We conducted an interviewer-administered questionnaire of visitors of critically ill patients in two family waiting rooms serving three intensive care units (ICUs) in Toronto, Canada. Respondents rated the importance of general and ventilation-related outcomes in two hypothetical scenarios (before a first spontaneous breathing trial, and after a failed spontaneous breathing trial) and selected a preferred technique for the breathing trials. With regard to the patient they were visiting, respondents identified the most important outcome to them at ICU admission, during the ICU stay, and at ICU discharge. We analyzed 322 questionnaires (95.5% response rate). All outcomes were highly rated (average range: 7.82-9.74). Across scenarios, outcomes rated as most important were ICU and hospital survival (9.72, 9.70), avoiding complications (9.45), quality of life (9.394), patient comfort (9.393), and returning to previous living arrangements (9.31). Overall, the most important ventilation-related outcomes were being ventilator-free (8.95), avoiding reintubation (8.905), and passing a spontaneous breathing trial (8.903). Passing a spontaneous breathing trial assumed greater importance after an initial failed attempt. "Time to event" outcomes were less important to visitors. We did not identify a preferred spontaneous breathing trial technique. Although ICU survival was the most important outcome at ICU admission and during the ICU stay, visitors rated quality of life higher than hospital survival at ICU discharge. Visitors to critically ill patients prioritized two general outcomes (ICU and hospital survival) and three ventilation-related outcomes (being ventilator free, avoiding reintubation, passing a spontaneous breathing trial), and valued avoiding complications, maintaining quality of life, comfort, and returning to previous living arrangements. The outcomes preferences of the survey respondents evolved temporally during the ICU stay.
Gray, A J; Goodacre, S; Newby, D E; Masson, M A; Sampson, F; Dixon, S; Crane, S; Elliott, M; Nicholl, J
2009-07-01
To determine whether non-invasive ventilation reduces mortality and whether there are important differences in outcome by treatment modality. Multicentre open prospective randomised controlled trial. Patients presenting with severe acute cardiogenic pulmonary oedema in 26 emergency departments in the UK. Inclusion criteria were age > 16 years, clinical diagnosis of acute cardiogenic pulmonary oedema, pulmonary oedema on chest radiograph, respiratory rate > 20 breaths per minute, and arterial hydrogen ion concentration > 45 nmol/l (pH < 7.35). Patients were randomised to standard oxygen therapy, continuous positive airway pressure (CPAP) (5-15 cmH2O) or non-invasive positive pressure ventilation (NIPPV) (inspiratory pressure 8-20 cmH2O, expiratory pressure 4-10 cmH2O) on a 1:1:1 basis for a minimum of 2 hours. The primary end point for the comparison between NIPPV or CPAP and standard therapy was 7-day mortality. The composite primary end point for the comparison of NIPPV and CPAP was 7-day mortality and tracheal intubation rate. Secondary end points were breathlessness, physiological variables, intubation rate, length of hospital stay and critical care admission rate. Economic evaluation took the form of a cost-utility analysis, taken from an NHS (and personal social services) perspective. In total, 1069 patients [mean age 78 (SD 10) years; 43% male] were recruited to standard therapy (n = 367), CPAP [n = 346; mean 10 (SD 4) cmH2O] or NIPPV [n = 356; mean 14 (SD 5)/7 (SD 2) cmH2O]. There was no difference in 7-day mortality for standard oxygen therapy (9.8%) and non-invasive ventilation (9.5%; p = 0.87). The combined end point of 7-day death and intubation rate was similar, irrespective of non-invasive ventilation modality (CPAP 11.7% versus NIPPV 11.1%; p = 0.81). Compared with standard therapy, non-invasive ventilation was associated with greater reductions (treatment difference, 95% confidence intervals) in breathlessness (visual analogue scale score 0.7, 0.2-1.3; p = 0.008) and heart rate (4/min, 1-6; p = 0.004) and improvement in acidosis (pH 0.03, 0.02-0.04; p < 0.001) and hypercapnia (0.7 kPa, 0.4-0.9; p < 0.001) at 1 hour. There were no treatment-related adverse events or differences in other secondary outcomes such as myocardial infarction rate, length of hospital stay, critical care admission rate and requirement for endotracheal intubation. Economic evaluation showed that mean costs and QALYs up to 6 months were 3023 pounds and 0.202 for standard therapy, 3224 pounds and 0.213 for CPAP, and 3208 pounds and 0.210 for NIPPV. Modelling of lifetime costs and QALYs produced values of 15,764 pounds and 1.597 for standard therapy, 17,525 pounds and 1.841 for CPAP, and 17,021 pounds and 1.707 for NIPPV. These results suggest that both CPAP and NIPPV accrue more QALYs but at higher cost than standard therapy. However, these estimates are subject to substantial uncertainty. Non-invasive ventilatory support delivered by either CPAP or NIPPV safely provides earlier improvement and resolution of breathlessness, respiratory distress and metabolic abnormality. However, this does not translate into improved short- or longer-term survival. We recommend that CPAP or NIPPV should be considered as adjunctive therapy in patients with severe acute cardiogenic pulmonary oedema in the presence of severe respiratory distress or when there is a failure to improve with pharmacological therapy. Current Controlled Trials ISRCTN07448447.
VA/Q distribution during heavy exercise and recovery in humans: implications for pulmonary edema
NASA Technical Reports Server (NTRS)
Schaffartzik, W.; Poole, D. C.; Derion, T.; Tsukimoto, K.; Hogan, M. C.; Arcos, J. P.; Bebout, D. E.; Wagner, P. D.
1992-01-01
Ventilation-perfusion (VA/Q) inequality has been shown to increase with exercise. Potential mechanisms for this increase include nonuniform pulmonary vasoconstriction, ventilatory time constant inequality, reduced large airway gas mixing, and development of interstitial pulmonary edema. We hypothesized that persistence of VA/Q mismatch after ventilation and cardiac output subside during recovery would be consistent with edema; however, rapid resolution would suggest mechanisms related to changes in ventilation and blood flow per se. Thirteen healthy males performed near-maximal cycle ergometry at an inspiratory PO2 of 91 Torr (because hypoxia accentuates VA/Q mismatch on exercise). Cardiorespiratory variables and inert gas elimination patterns were measured at rest, during exercise, and between 2 and 30 min of recovery. Two profiles of VA/Q distribution behavior emerged during heavy exercise: in group 1 an increase in VA/Q mismatch (log SDQ of 0.35 +/- 0.02 at rest and 0.44 +/- 0.02 at exercise; P less than 0.05, n = 7) and in group 2 no change in VA/Q mismatch (n = 6). There were no differences in anthropometric data, work rate, O2 uptake, or ventilation during heavy exercise between groups. Group 1 demonstrated significantly greater VA/Q inequality, lower vital capacity, and higher forced expiratory flow at 25-75% of forced vital capacity for the first 20 min during recovery than group 2. Cardiac index was higher in group 1 both during heavy exercise and 4 and 6 min postexercise. However, both ventilation and cardiac output returned toward baseline values more rapidly than did VA/Q relationships. Arterial pH was lower in group 1 during exercise and recovery. We conclude that greater VA/Q inequality in group 1 and its persistence during recovery are consistent with the hypothesis that edema occurs and contributes to the increase in VA/Q inequality during exercise. This is supported by observation of greater blood flows and acidosis and, presumably therefore, higher pulmonary vascular pressures in such subjects.
Early non-invasive ventilation treatment for severe influenza pneumonia.
Masclans, J R; Pérez, M; Almirall, J; Lorente, L; Marqués, A; Socias, L; Vidaur, L; Rello, J
2013-03-01
The role of non-invasive ventilation (NIV) in acute respiratory failure caused by viral pneumonia remains controversial. Our objective was to evaluate the use of NIV in a cohort of (H1N1)v pneumonia. Usefulness and success of NIV were assessed in a prospective, observational registry of patients with influenza A (H1N1) virus pneumonia in 148 Spanish intensive care units (ICUs) in 2009-10. Significant variables for NIV success were included in a multivariate analysis. In all, 685 patients with confirmed influenza A (H1N1)v viral pneumonia were admitted to participating ICUs; 489 were ventilated, 177 with NIV. The NIV was successful in 72 patients (40.7%), the rest required intubation. Low Acute Physiology and Chronic Health Evaluation (APACHE) II, low Sequential Organ Failure Assessment (SOFA) and absence of renal failure were associated with NIV success. Success of NIV was independently associated with fewer than two chest X-ray quadrant opacities (OR 3.5) and no vasopressor requirement (OR 8.1). However, among patients with two or more quadrant opacities, a SOFA score ≤7 presented a higher success rate than those with SOFA score >7 (OR 10.7). Patients in whom NIV was successful required shorter ventilation time, shorter ICU stay and hospital stay than NIV failure. In patients in whom NIV failed, the delay in intubation did not increase mortality (26.5% versus 24.2%). Clinicians used NIV in 25.8% of influenza A (H1N1)v viral pneumonia admitted to ICU, and treatment was effective in 40.6% of them. NIV success was associated with shorter hospital stay and mortality similar to non-ventilated patients. NIV failure was associated with a mortality similar to those who were intubated from the start. © 2012 The Authors. Clinical Microbiology and Infection © 2012 European Society of Clinical Microbiology and Infectious Diseases.
Kum, Oyeon
2018-06-01
An optimized air ventilation system design for a treatment room in Heavy-ion Medical Facility is an important issue in the aspects of nuclear safety because the activated air produced in a treatment room can directly affect the medical staff and the general public in the radiation-free area. Optimized design criteria of air ventilation system for a clinical room in 430 MeV/u carbon ion beam medical accelerator facility was performed by using a combination of MCNPX2.7.0 and CINDER'90 codes. Effective dose rate and its accumulated effective dose by inhalation and residual gamma were calculated for a normal treatment scenario (2 min irradiation for one fraction) as a function of decay time. Natural doses around the site were measured before construction and used as reference data. With no air ventilation system, the maximum effective dose rate was about 3 μSv/h (total dose of 90 mSv/y) and minimum 0.2 μSv/h (total dose of 6 mSv/y), which are over the legal limits for medical staff and for the general public. Although inhalation dose contribution was relatively small, it was considered seriously because of its long-lasting effects in the body. The integrated dose per year was 1.8 mSv/y in the radiation-free area with the 20-min rate of air ventilation system. An optimal air ventilation rate of 20 min is proposed for a clinical room, which also agrees with the best mechanical design value. © 2018 American Association of Physicists in Medicine.
Atmospheric turbulence triggers pronounced diel pattern in karst carbonate geochemistry
NASA Astrophysics Data System (ADS)
Roland, M.; Serrano-Ortiz, P.; Kowalski, A. S.; Goddéris, Y.; Sánchez-Cañete, E. P.; Ciais, P.; Domingo, F.; Cuezva, S.; Sanchez-Moral, S.; Longdoz, B.; Yakir, D.; Van Grieken, R.; Schott, J.; Cardell, C.; Janssens, I. A.
2013-07-01
CO2 exchange between terrestrial ecosystems and the atmosphere is key to understanding the feedbacks between climate change and the land surface. In regions with carbonaceous parent material, CO2 exchange patterns occur that cannot be explained by biological processes, such as disproportionate outgassing during the daytime or nighttime CO2 uptake during periods when all vegetation is senescent. Neither of these phenomena can be attributed to carbonate weathering reactions, since their CO2 exchange rates are too small. Soil ventilation induced by high atmospheric turbulence is found to explain atypical CO2 exchange between carbonaceous systems and the atmosphere. However, by strongly altering subsurface CO2 concentrations, ventilation can be expected to influence carbonate weathering rates. By imposing ventilation-driven CO2 outgassing in a carbonate weathering model, we show here that carbonate geochemistry is accelerated and does play a surprisingly large role in the observed CO2 exchange pattern of a semi-arid ecosystem. We found that by rapidly depleting soil CO2 during the daytime, ventilation disturbs soil carbonate equilibria and therefore strongly magnifies daytime carbonate precipitation and associated CO2 production. At night, ventilation ceases and the depleted CO2 concentrations increase steadily. Dissolution of carbonate is now enhanced, which consumes CO2 and largely compensates for the enhanced daytime carbonate precipitation. This is why only a relatively small effect on global carbonate weathering rates is to be expected. On the short term, however, ventilation has a drastic effect on synoptic carbonate weathering rates, resulting in a pronounced diel pattern that exacerbates the non-biological behavior of soil-atmosphere CO2 exchanges in dry regions with carbonate soils.
Batterman, Stuart
2017-01-01
The ventilation rate (VR) is a key parameter affecting indoor environmental quality (IEQ) and the energy consumption of buildings. This paper reviews the use of CO2 as a “natural” tracer gas for estimating VRs, focusing on applications in school classrooms. It provides details and guidance for the steady-state, build-up, decay and transient mass balance methods. An extension to the build-up method and an analysis of the post-exercise recovery period that can increase CO2 generation rates are presented. Measurements in four mechanically-ventilated school buildings demonstrate the methods and highlight issues affecting their applicability. VRs during the school day fell below recommended minimum levels, and VRs during evening and early morning were on the order of 0.1 h−1, reflecting shutdown of the ventilation systems. The transient mass balance method was the most flexible and advantageous method given the low air change rates and dynamic occupancy patterns observed in the classrooms. While the extension to the build-up method improved stability and consistency, the accuracy of this and the steady-state method may be limited. Decay-based methods did not reflect the VR during the school day due to heating, ventilation and air conditioning (HVAC) system shutdown. Since the number of occupants in classrooms changes over the day, the VR expressed on a per person basis (e.g., L·s−1·person−1) depends on the occupancy metric. If occupancy measurements can be obtained, then the transient mass balance method likely will provide the most consistent and accurate results among the CO2-based methods. Improved VR measurements can benefit many applications, including research examining the linkage between ventilation and health. PMID:28165398
Batterman, Stuart
2017-02-04
The ventilation rate (VR) is a key parameter affecting indoor environmental quality (IEQ) and the energy consumption of buildings. This paper reviews the use of CO₂ as a "natural" tracer gas for estimating VRs, focusing on applications in school classrooms. It provides details and guidance for the steady-state, build-up, decay and transient mass balance methods. An extension to the build-up method and an analysis of the post-exercise recovery period that can increase CO₂ generation rates are presented. Measurements in four mechanically-ventilated school buildings demonstrate the methods and highlight issues affecting their applicability. VRs during the school day fell below recommended minimum levels, and VRs during evening and early morning were on the order of 0.1 h -1 , reflecting shutdown of the ventilation systems. The transient mass balance method was the most flexible and advantageous method given the low air change rates and dynamic occupancy patterns observed in the classrooms. While the extension to the build-up method improved stability and consistency, the accuracy of this and the steady-state method may be limited. Decay-based methods did not reflect the VR during the school day due to heating, ventilation and air conditioning (HVAC) system shutdown. Since the number of occupants in classrooms changes over the day, the VR expressed on a per person basis (e.g., L·s -1 ·person -1 ) depends on the occupancy metric. If occupancy measurements can be obtained, then the transient mass balance method likely will provide the most consistent and accurate results among the CO₂-based methods. Improved VR measurements can benefit many applications, including research examining the linkage between ventilation and health.
Amanati, Ali; Karimi, Abdollah; Fahimzad, Alireza; Shamshiri, Ahmad Reza; Fallah, Fatemeh; Mahdavi, Alireza; Talebian, Mahshid
2017-01-01
Background: Among hospital-acquired infections (HAIs) in children, ventilator-associated pneumonia (VAP) is the most common after blood stream infection (BSI). VAP can prolong length of ventilation and hospitalization, increase mortality rate, and directly change a patient’s outcome in Pediatric Intensive Care Units (PICU). Objectives: The research on VAP in children is limited, especially in Iran; therefore, the identification of VAP incidence and mortality rate will be important for both clinical and epidemiological implications. Materials and Methods: Mechanically ventilated pediatric patients were assessed for development of VAP during hospital course on the basis of clinical, laboratory and imaging criteria. We matched VAP group with control group for assessment of VAP related mortality in the critically ill ventilated children. Results: VAP developed in 22.9% of critically ill children undergoing mechanical ventilation. Early VAP and late VAP were found in 19.3% and 8.4% of VAP cases, respectively. Among the known VAP risk factors that were investigated, immunodeficiency was significantly greater in the VAP group (p = 0.014). No significant differences were found between the two groups regarding use of corticosteroids, antibiotics, PH (potential of hydrogen) modifying agents (such as ranitidine or pantoprazole), presence of nasogastric tube and total or partial parenteral nutrition administration. A substantial number of patients in the VAP group had more than four risk factors for development of VAP, compared to those without VAP (p = 0.087). Mortality rate was not statistically different between the VAP and control groups (p = 0.477). Conclusion: VAP is still one of the major causes of mortality in PICUs. It is found that altered immune status is a significant risk factor for acquiring VAP. Also, occurrence of VAP was high in the first week after admission in PICU. PMID:28671616
Bennett, D H; Fisk, W; Apte, M G; Wu, X; Trout, A; Faulkner, D; Sullivan, D
2012-08-01
This field study of 37 small and medium commercial buildings throughout California obtained information on ventilation rate, temperature, and heating, ventilating, and air-conditioning (HVAC) system characteristics. The study included seven retail establishments; five restaurants; eight offices; two each of gas stations, hair salons, healthcare facilities, grocery stores, dental offices, and fitness centers; and five other buildings. Fourteen (38%) of the buildings either could not or did not provide outdoor air through the HVAC system. The air exchange rate averaged 1.6 (s.d. = 1.7) exchanges per hour and was similar between buildings with and without outdoor air supplied through the HVAC system, indicating that some buildings have significant leakage or ventilation through open windows and doors. Not all buildings had sufficient air exchange to meet ASHRAE 62.1 Standards, including buildings used for fitness centers, hair salons, offices, and retail establishments. The majority of the time, buildings were within the ASHRAE temperature comfort range. Offices were frequently overcooled in the summer. All of the buildings had filters, but over half the buildings had a filter with a minimum efficiency reporting value rating of 4 or lower, which are not very effective for removing fine particles. Most U.S. commercial buildings (96%) are small- to medium-sized, using nearly 18% of the country's energy, and sheltering a large population daily. Little is known about the ventilation systems in these buildings. This study found a wide variety of ventilation conditions, with many buildings failing to meet relevant ventilation standards. Regulators may want to consider implementing more complete building inspections at commissioning and point of sale. © 2012 John Wiley & Sons A/S.
NASA Astrophysics Data System (ADS)
Krivonogov, Nikolay G.; Efimova, Nataliya Y.; Zavadovsky, Konstantin W.; Lishmanov, Yuri B.
2016-08-01
Ventilation/perfusion lung scintigraphy was performed in 39 patients with verified diagnosis of community-acquired pneumonia (CAP) and in 14 patients with peripheral lung cancer. Ventilation/perfusion ratio, apical-basal gradients of ventilation (U/L(V)) and lung perfusion (U/L(P)), and alveolar capillary permeability of radionuclide aerosol were determined based on scintigraphy data. The study demonstrated that main signs of CAP were increases in ventilation/perfusion ratio, perfusion and ventilation gradient on a side of the diseased lung, and two-side increase in alveolar capillary permeability rate for radionuclide aerosol. Unlike this, scintigraphic signs of peripheral lung cancer comprise an increase in ventilation/perfusion ratio over 1.0 on a side of the diseased lung with its simultaneous decrease on a contralateral side, normal values of perfusion and ventilation gradients of both lungs, and delayed alveolar capillary clearance in the diseased lung compared with the intact lung.
Control of airborne infectious diseases in ventilated spaces
Nielsen, Peter V.
2009-01-01
We protect ourselves from airborne cross-infection in the indoor environment by supplying fresh air to a room by natural or mechanical ventilation. The air is distributed in the room according to different principles: mixing ventilation, displacement ventilation, etc. A large amount of air is supplied to the room to ensure a dilution of airborne infection. Analyses of the flow in the room show that there are a number of parameters that play an important role in minimizing airborne cross-infection. The air flow rate to the room must be high, and the air distribution pattern can be designed to have high ventilation effectiveness. Furthermore, personalized ventilation may reduce the risk of cross-infection, and in some cases, it can also reduce the source of infection. Personalized ventilation can especially be used in hospital wards, aircraft cabins and, in general, where people are in fixed positions. PMID:19740921
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krivonogov, Nikolay G., E-mail: kng@cardio-tomsk.ru; Efimova, Nataliya Y., E-mail: efimova@cardio-tomsk.ru; Zavadovsky, Konstantin W.
Ventilation/perfusion lung scintigraphy was performed in 39 patients with verified diagnosis of community-acquired pneumonia (CAP) and in 14 patients with peripheral lung cancer. Ventilation/perfusion ratio, apical-basal gradients of ventilation (U/L(V)) and lung perfusion (U/L(P)), and alveolar capillary permeability of radionuclide aerosol were determined based on scintigraphy data. The study demonstrated that main signs of CAP were increases in ventilation/perfusion ratio, perfusion and ventilation gradient on a side of the diseased lung, and two-side increase in alveolar capillary permeability rate for radionuclide aerosol. Unlike this, scintigraphic signs of peripheral lung cancer comprise an increase in ventilation/perfusion ratio over 1.0 on amore » side of the diseased lung with its simultaneous decrease on a contralateral side, normal values of perfusion and ventilation gradients of both lungs, and delayed alveolar capillary clearance in the diseased lung compared with the intact lung.« less
Dose monitoring in Partial Liquid Ventilation by infrared measurement of expired perfluorochemicals.
Mazzoni, M; Nugent, L; Klein, D; Hoffman, J; Sekins, K M; Flaim, S F
1999-01-01
Patients undergoing Partial Liquid Ventilation (PLV) with the perfluorochemical liquid perflubron (PFB) continuously evaporate the drug from the lung during ventilatory expiration. In this study, two infrared (IR) devices, a modified industrial analyzer ("experimental prototype") and a custom-designed device suitable for use in a clinical environment ("clinical prototype"), were calibrated and validated on the bench to measure a range of PFB concentrations (CPFB) in a gas stream. PFB loss from the lung (area under the CPFB-vs-time-curve) could be correlated during PLV simulation with changes in tidal volume, breathing rate, and variable CPFB-vs-time profiles. The two IR devices produced nearly identical measurements for the same CPFB standards (maximum deviation = 1.5%). The experimental IR prototype was tested in 17 anesthetized, paralyzed, and ventilated swine (42-53 kg) to quantify the total amount and rate of evaporate loss of PFB over 12 hours of PLV, both with and without periodic supplemental PFB doses. The residual PFB volumes in the animal lungs at the end of the study, as determined by a gravimetric postmortem lung method, were found to agree on average for all animals to within 10% of the residual PFB volume as predicted by the IR approach. Furthermore, the IR signal of CPFB does not appear to correlate with the absolute amount of PFB in the lungs, but may reflect the relative proportion of PFB-wetted airway and alveolar surface. The authors conclude that IR quantitation of PFB evaporative loss is acceptably accurate for extended periods of PLV and may be a useful tool in the clinic for PFB dose monitoring and maintenance, thereby helping to optimize PLV treatment.
Gupta, Samir; Sinha, Sunil K; Tin, Win; Donn, Steven M
2009-05-01
To compare the efficacy and safety of bubble continuous positive airway pressure (CPAP) and Infant Flow Driver (IFD) CPAP for the post-extubation management of preterm infants with respiratory distress syndrome (RDS). A total of 140 preterm infants at 24 to 29 weeks' gestation or with a birth weight of 600 to 1500 g who were ventilated at birth for RDS were randomized to receive either IFD CPAP (a variable-flow device) or bubble CPAP (a continuous-flow device). A standardized protocol was used for extubation and CPAP. No crossover was allowed. The primary outcome was successful extubation maintained for at least 72 hours. Secondary outcomes included successful extubation maintained for 7 days, total duration of CPAP support, chronic lung disease, and complications of prematurity. Seventy-one infants were randomized to bubble CPAP, and 69 were randomized to IFD CPAP. Mean gestational age and birth weight were similar in the 2 groups, as were the proportions of infants who achieved successful extubation for 72 hours and for 7 days. However, the median duration of CPAP support was 50% shorter in the infants on bubble CPAP. Moreover, in the subset of infants who were ventilated for less than 14 days, the infants on bubble CPAP had a significantly lower extubation failure rate. There was no difference in the incidence of chronic lung disease or other complications between the 2 study groups. Bubble CPAP is as effective as IFD CPAP in the post-extubation management of infants with RDS; however, in infants ventilated for < or = 14 days, bubble CPAP is associated with a significantly higher rate of successful extubation. Bubble CPAP also is associated with a significantly reduced duration of CPAP support.
Prediction and Outcome of Intensive Care Unit-Acquired Paresis.
Peñuelas, Oscar; Muriel, Alfonso; Frutos-Vivar, Fernando; Fan, Eddy; Raymondos, Konstantinos; Rios, Fernando; Nin, Nicolás; Thille, Arnaud W; González, Marco; Villagomez, Asisclo J; Davies, Andrew R; Du, Bin; Maggiore, Salvatore M; Matamis, Dimitrios; Abroug, Fekri; Moreno, Rui P; Kuiper, Michael A; Anzueto, Antonio; Ferguson, Niall D; Esteban, Andrés
2018-01-01
Intensive care unit-acquired paresis (ICUAP) is associated with poor outcomes. Our objective was to evaluate predictors for ICUAP and the short-term outcomes associated with this condition. A secondary analysis of a prospective study including 4157 mechanically ventilated adults in 494 intensive care units from 39 countries. After sedative interruption, patients were screened for ICUAP daily, which was defined as the presence of symmetric and flaccid quadriparesis associated with decreased or absent deep tendon reflexes. A multinomial logistic regression was used to create a predictive model for ICUAP. Propensity score matching was used to estimate the relationship between ICUAP and short-term outcomes (ie, weaning failure and intensive care unit [ICU] mortality). Overall, 114 (3%) patients had ICUAP. Variables associated with ICUAP were duration of mechanical ventilation (relative risk ratio [RRR] per day, 1.10; 95% confidence interval [CI] 1.08-1.12), steroid therapy (RRR 1.8; 95% CI, 1.2-2.8), insulin therapy (RRR 1.8; 95% CI 1.2-2.7), sepsis (RRR 1.9; 95% CI: 1.2 to 2.9), acute renal failure (RRR 2.2; 95% CI 1.5-3.3), and hematological failure (RRR 1.9; 95% CI: 1.2-2.9). Coefficients were used to generate a weighted scoring system to predict ICUAP. ICUAP was significantly associated with both weaning failure (paired rate difference of 22.1%; 95% CI 9.8-31.6%) and ICU mortality (paired rate difference 10.5%; 95% CI 0.1-24.0%). Intensive care unit-acquired paresis is relatively uncommon but is significantly associated with weaning failure and ICU mortality. We constructed a weighted scoring system, with good discrimination, to predict ICUAP in mechanically ventilated patients at the time of awakening.
Frade-Mera, M J; Regueiro-Díaz, N; Díaz-Castellano, L; Torres-Valverde, L; Alonso-Pérez, L; Landívar-Redondo, M M; Muñoz-Pasín, R; Terceros-Almanza, L J; Temprano-Vázquez, S; Sánchez-Izquierdo-Riera, J Á
Safe analgesia and sedation strategies are necessary in order to avoid under or over sedation, as well as improving the comfort and safety of critical care patients. To compare and contrast a multidisciplinary protocol of systematic evaluation and management of analgesia and sedation in a group of critical care patients on mechanical ventilation with the usual procedures. A cohort study with contemporary series was conducted in a tertiary care medical-surgical ICU February to November during 2013 and 2014. The inclusion criteria were mechanical ventilation ≥ 24h and use of sedation by continuous infusion. Sedation was monitored using the Richmond agitation-sedation scale or bispectral index, and analgesia were measured using the numeric rating scale, or behavioural indicators of pain scale. The study variables included; mechanical ventilation time, weaning time, ventilation support time, artificial airway time, continuous sedative infusion time, daily dose and frequency of analgesic and sedative drug use, hospital stay, and ICU and hospital mortality, Richmond agitation-sedation scale, bispectral index, numeric rating scale, and behavioural indicators of pain scale measurements. Kruskal Wallis and Chi 2 , and a significance of p<.05 were used. The study included 153 admissions, 75 pre-intervention and 78 post-intervention, with a mean age of 55.7±13 years old, and 67% men. Both groups showed similarities in age, reason for admission, and APACHE. There were non-significant decreases in mechanical ventilation time 4 (1.4-9.2) and 3.2 (1.4-8.1) days, respectively; p= 0.7, continuous sedative infusion time 6 (3-11) and 5 (3-11) days; p= 0.9, length of hospital stay 29 (18-52); 25 (14-41) days; p= 0.1, ICU mortality (8 vs. 5%; p= 0.4), and hospital mortality (10.6 vs. 9.4%: p= 0.8). Daily doses of midazolam and remifentanil decreased 347 (227-479) mg/day; 261 (159-358) mg/day; p= 0.02 and 2175 (1427-3285) mcg/day; 1500 (715-2740) mcg/day; p= 0.02, respectively. There were increases in the use of remifentanil (32% vs. 51%; p= 0.01), dexmedetomidine (0 vs.6%; p= 0.02), dexketoprofen (60 vs. 76%; p= 0.03), and haloperidol (15 vs.28%; p= 0.04). The use of morphine decreased (71 vs. 54%; p= 0.03). There was an increase in the number of measurements and Richmond agitation-sedation scale scores 6 (3-17); 21 (9-39); p< 0.0001, behavioural indicators of pain scale 6 (3-18); 19(8-33); p< 0.001 and numeric rating scale 4 (2-6); 8 (6-17); p< 0.0001. The implementation of a multidisciplinary protocol of systematic evaluation of analgesia and sedation management achieved an improvement in monitoring and adequacy of dose to patient needs, leading to improved outcomes. Copyright © 2015 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
A novel method for right one-lung ventilation modeling in rabbits.
Xu, Ze-Ping; Gu, Lian-Bing; Bian, Qing-Ming; Li, Peng-Yi; Wang, Li-Jun; Chen, Xiao-Xiang; Zhang, Jing-Yuan
2016-08-01
There is no standard method by which to establish a right one-lung ventilation (OLV) model in rabbits. In the present study, a novel method is proposed to compare with two other methods. After 0.5 h of baseline two-lung ventilation (TLV), 40 rabbits were randomly divided into sham group (TLV for 3 h as a contrast) and three right-OLV groups (right OLV for 3 h with different methods): Deep intubation group, clamp group and blocker group (deeply intubate the self-made bronchial blocker into the left main bronchus, the novel method). These three methods were compared using a number of variables: Circulation by heart rate (HR), mean arterial pressure (MAP); oxygenation by arterial blood gas analysis; airway pressure; lung injury by histopathology; and time, blood loss, success rate of modeling. Following OLV, compared with the sham group, arterial partial pressure of oxygen and arterial hemoglobin oxygen saturation decreased, peak pressure increased and lung injury scores were higher in three OLV groups at 3 h of OLV. All these indexes showed no differences between the three OLV groups. During right-OLV modeling, less time was spent in the blocker group (6±2 min), compared with the other two OLV groups (13±4 min in deep intubation group, P<0.05; 33±9 min in clamp group, P<0.001); more blood loss was observed in clamp group (11.7±2.8 ml), compared with the other two OLV groups (2.3±0.5 ml in deep intubation group, P<0.001; 2.1±0.6 ml in blocker group, P<0.001). The first-time and final success rate of modeling showed no differences among the three OLV groups. Deep intubation of the self-made bronchial blocker into the left main bronchus is an easy, effective and reliable method to establish a right-OLV model in rabbits.
A novel method for right one-lung ventilation modeling in rabbits
Xu, Ze-Ping; Gu, Lian-Bing; Bian, Qing-Ming; Li, Peng-Yi; Wang, Li-Jun; Chen, Xiao-Xiang; Zhang, Jing-Yuan
2016-01-01
There is no standard method by which to establish a right one-lung ventilation (OLV) model in rabbits. In the present study, a novel method is proposed to compare with two other methods. After 0.5 h of baseline two-lung ventilation (TLV), 40 rabbits were randomly divided into sham group (TLV for 3 h as a contrast) and three right-OLV groups (right OLV for 3 h with different methods): Deep intubation group, clamp group and blocker group (deeply intubate the self-made bronchial blocker into the left main bronchus, the novel method). These three methods were compared using a number of variables: Circulation by heart rate (HR), mean arterial pressure (MAP); oxygenation by arterial blood gas analysis; airway pressure; lung injury by histopathology; and time, blood loss, success rate of modeling. Following OLV, compared with the sham group, arterial partial pressure of oxygen and arterial hemoglobin oxygen saturation decreased, peak pressure increased and lung injury scores were higher in three OLV groups at 3 h of OLV. All these indexes showed no differences between the three OLV groups. During right-OLV modeling, less time was spent in the blocker group (6±2 min), compared with the other two OLV groups (13±4 min in deep intubation group, P<0.05; 33±9 min in clamp group, P<0.001); more blood loss was observed in clamp group (11.7±2.8 ml), compared with the other two OLV groups (2.3±0.5 ml in deep intubation group, P<0.001; 2.1±0.6 ml in blocker group, P<0.001). The first-time and final success rate of modeling showed no differences among the three OLV groups. Deep intubation of the self-made bronchial blocker into the left main bronchus is an easy, effective and reliable method to establish a right-OLV model in rabbits. PMID:27446346
Indoor Air Quality Assessment of the San Francisco Federal Building
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apte, Michael; Bennett, Deborah H.; Faulkner, David
2008-07-01
An assessment of the indoor air quality (IAQ) of the San Francisco Federal Building (SFFB) was conducted on May 12 and 14, 2009 at the request of the General Services Administration (GSA). The purpose of the assessment was for a general screening of IAQ parameters typically indicative of well functioning building systems. One naturally ventilated space and one mechanically ventilated space were studied. In both zones, the levels of indoor air contaminants, including CO2, CO, particulate matter, volatile organic compounds, and aldehydes, were low, relative to reference exposure levels and air quality standards for comparable office buildings. We found slightlymore » elevated levels of volatile organic compounds (VOCs) including two compounds often found in"green" cleaning products. In addition, we found two industrial solvents at levels higher than typically seen in office buildings, but the levels were not sufficient to be of a health concern. The ventilation rates in the two study spaces were high by any standard. Ventilation rates in the building should be further investigated and adjusted to be in line with the building design. Based on our measurements, we conclude that the IAQ is satisfactory in the zone we tested, but IAQ may need to be re-checked after the ventilation rates have been lowered.« less
Wientjes, C J; Grossman, P; Gaillard, A W
1998-09-01
Assessment of multiple respiratory measures may provide insight into how behavioral demands affect the breathing pattern. This is illustrated by data from a study among 44 subjects, in which tidal volume, respiration rate, minute ventilation and indices of central drive and timing mechanisms were assessed via inductive plethysmography, in addition to end-tidal PCO2. After a baseline, three conditions of a memory comparison task were presented. The first two conditions differed only with regard to the presence or absence of feedback of performance (NFB and FB). In the third 'all-or-nothing' (AON) condition, subjects only received a monetary bonus, if their performance exceeded that of the previous two conditions. Minute ventilation increased from baseline to all task conditions, and from NFB and FB to AON. Respiration rate increased in all task conditions, but there were no differences between task conditions. Tidal volume decreased during NFB, but was equal to baseline during FB and AON. Of the respiratory control indices, inspiratory flow rate covaried much more closely with minute ventilation than duty cycle. The task performance induced a minor degree of hyperventilation. The discussion focusses on how behavioral demands affect respiratory control processes to produce alterations in breathing pattern and ventilation.
Neonatal air leak syndrome and the role of high-frequency ventilation in its prevention.
Jeng, Mei-Jy; Lee, Yu-Sheng; Tsao, Pei-Chen; Soong, Wen-Jue
2012-11-01
Air leak syndrome includes pulmonary interstitial emphysema, pneumothorax, pneumomediastinum, pneumopericardium, pneumoperitoneum, subcutaneous emphysema, and systemic air embolism. The most common cause of air leak syndrome in neonates is inadequate mechanical ventilation of the fragile and immature lungs. The incidence of air leaks in newborns is inversely related to the birth weight of the infants, especially in very-low-birth-weight and meconium-aspirated infants. When the air leak is asymptomatic and the infant is not mechanically ventilated, there is usually no specific treatment. Emergent needle aspiration and/or tube drainage are necessary in managing tension pneumothorax or pneumopericardium with cardiac tamponade. To prevent air leak syndrome, gentle ventilation with low pressure, low tidal volume, low inspiratory time, high rate, and judicious use of positive end expiratory pressure are the keys to caring for mechanically ventilated infants. Both high-frequency oscillatory ventilation (HFOV) and high-frequency jet ventilation (HFJV) can provide adequate gas exchange using extremely low tidal volume and supraphysiologic rate in neonates with acute pulmonary dysfunction, and they are considered to have the potential to reduce the risks of air leak syndrome in neonates. However, there is still no conclusive evidence that HFOV or HFJV can help to reduce new air leaks in published neonatal clinical trials. In conclusion, neonatal air leaks may present as a thoracic emergency requiring emergent intervention. To prevent air leak syndrome, gentle ventilations are key to caring for ventilated infants. There is insufficient evidence showing the role of HFOV and HFJV in the prevention or reduction of new air leaks in newborn infants, so further investigation will be necessary for future applications. Copyright © 2012. Published by Elsevier B.V.
Patil, Gurulingappa; Nikhil, M.
2016-01-01
Introduction One of the most common causes of poisoning in agricultural based developing countries like India is due to Organophosphorus (OP) compound. Its widespread use and easy availability has increased the likelihood of poisoning with these compounds. Aim To study the morbidity and mortality in patients with acute OP poisoning requiring mechanical ventilation. Materials and Methods This was a retrospective study constituting patients of all age groups admitted to the Intensive Care Unit (ICU) with diagnosis of OP poisoning between January 2015 to December 2015. Of 66 OP poisoning cases those patients who went against medical advice, 20 were excluded from the study and thus 46 patients were included. Diagnosis was performed from the history taken either from the patient or from the patient’s relatives and presenting symptoms. Demographic data, month of the year, age of patient, mode of poisoning, cholinesterase levels, duration of mechanical ventilation and mortality were recorded. Data are presented as mean±SD. Results A 97.83% (45/46) of cases were suicidal. Out of 46, 9 were intubated and mechanically ventilated. Duration of mechanical ventilation varied from less than 48 hours to more than 7 days. Mortality rate was 50%, 0% and 100% in those who required mechanical ventilation for more than 7 days, 2 to 7 days and <2days respectively. None of the predictors like age, severity of poisoning, cholinesterase levels and duration of ventilation were independent predictors of death and all of them contributed to the mortality. Overall mortality rate in those who required mechanical ventilation was 22.22%. Conclusion Morbidity and mortality due to OP poisoning is directly proportional to the age, severity of poisoning and duration of mechanical ventilation and inversely proportional to serum cholinesterase level. PMID:28208980
Zuraimi, M S; Tham, K W; Chew, F T; Ooi, P L
2007-08-01
This paper reports the effects of ventilation strategies on indoor air quality (IAQ) and respiratory health of children within 104 child care centers (CCCs) in a hot and humid climate. The CCCs were categorized by ventilation strategies: natural (NV), air-conditioned and mechanically ventilated (ACMV), air-conditioned using split units (AC), and hybrid (NV and AC operated intermittently). The concentration levels of IAQ parameters in NV CCCs are characterized by the influence of the outdoors and good dilution of indoor pollutants. The lower ventilation rates in air-conditioned CCCs result in higher concentrations of occupant-related pollutants but lower outdoor pollutant ingress. This study also revealed lower prevalence for most asthma and allergy, and respiratory symptoms in children attending NV CCCs. In multivariate analyses controlled for the effects of confounders, the risk of current rhinitis among children is significantly higher if they attend mechanically ventilated CCCs compared to NV CCCs. Air-conditioned CCCs were also associated with higher adjusted prevalence ratio of severe phlegm and cough symptoms and lower respiratory illness. Finally, children attending CCCs with hybrid ventilation are at high risk for almost all the respiratory symptoms studied. This large field study indicates that different ventilation strategies employed by child care centers can cause significant variations in the indoor air quality and prevalence of asthma, allergies and respiratory symptoms of attending children. The higher prevalence rates of allergic and respiratory symptoms among young children, whose immune system is still under-developed, in child care centers, whether fully or partially air-conditioned, suggest that ventilation and plausible growth and propagation mechanisms of allergens and infectious agents be further investigated.
Knowledge level of nurses in Jordan on ventilator-associated pneumonia and preventive measures.
Hassan, Zeinab M; Wahsheh, Moayad A
2017-05-01
Ventilator-associated pneumonia is the most prevalent infection in Intensive Care Units, with the highest mortality rate; crude mortality rates may be as high as 20-75%. Many practices such as prevention measures (e.g. hand washing, wearing gloves, suctioning, elevated head of bed between 30° and 45°) have demonstrated an effect of reducing the incidence of this infection. To identify the level of nurses' knowledge of ventilator-associated pneumonia and prevention measures before an educational programme, identify the level of nurses' knowledge on ventilator-associated pneumonia and prevention post an educational programme and identify the reasons for not applying ventilator-associated pneumonia prevention measures among nurses in Jordan. Pre- and post-intervention observational study. Data based on a self-reported questionnaire from 428 nurses who worked in intensive care units were analysed. PowerPoint lectures, videos, printed materials and electronic materials were used in the intervention. Paired t-tests were used to test research questions. More than three-quarters of nurses had a low knowledge level regarding pathophysiology, risk factors and ventilator-associated pneumonia preventative measures. Nurses showed significant improvements in mean scores on the knowledge level of ventilator-associated pneumonia and prevention measures after an educational programme (p < 0.05). The main reasons for not applying prevention measures were the lack of time and no followed protocols in the units. Health education programmes about ventilator-associated pneumonia must be conducted among nurses in Jordan through continuous education. Hospital and nursing administrators should be actively involved in educational programmes and in assuring support for continuing education. Protocol for ventilator-associated pneumonia prevention should be developed based on current evidence-based guidelines. © 2016 British Association of Critical Care Nurses.
Rabec, C; Cuvelier, A; Cheval, C; Jaffre, S; Janssens, J-P; Mercy, M; Prigent, A; Rouault, S; Talbi, S; Vandenbroeck, S; Gonzalez-Bermejo, J
2016-12-01
A task force issued from the Groupe Assistance Ventilatoire (GAV) of the Société de Pneumologie de Langue Française (SPLF) was committed to develop a series of expert advice concerning various practical topics related to long-term non invasive ventilation by applying the Choosing Wisely ® methodology. Three topics were selected: monitoring of noninvasive ventilation, the interpretation of data obtained from built-in devices coupled to home ventilators and the role of hybrid modes (target volume with variable pressure support. For each topic, the experts have developed practical tips based on a comprehensive analysis of recent insights and evidence from the literature and from clinical experience. Copyright © 2016 SPLF. Published by Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Less, Brennan; Walker, Iain; Tang, Yihuan
2014-06-01
Smart ventilation systems use controls to ventilate more during those periods that provide either an energy or IAQ advantage (or both) and less during periods that provide a dis advantage. Using detailed building simulations, this study addresses one of the simplest and lowest cost types of smart controllers —outdoor temperature- based control. If the outdoor temperature falls below a certain cut- off, the fan is simply turned off. T he main principle of smart ventilation used in this study is to shift ventilation from time periods with large indoor -outdoor temperature differences, to periods where these differences are smaller, andmore » their energy impacts are expected to be less. Energy and IAQ performance are assessed relative to a base case of a continuously operated ventilation fan sized to comply with ASHRAE 62.2-2013 whole house ventilation requirements. In order to satisfy 62.2-2013, annual pollutant exposure must be equivalent between the temperature controlled and continuous fan cases. This requires ventilation to be greater than 62.2 requirements when the ventilation system operates. This is achieved by increasing the mechanical ventilation system air flow rates.« less
Adherence to the items in a bundle for the prevention of ventilator-associated pneumonia.
Sachetti, Amanda; Rech, Viviane; Dias, Alexandre Simões; Fontana, Caroline; Barbosa, Gilberto da Luz; Schlichting, Dionara
2014-01-01
To assess adherence to a ventilator care bundle in an intensive care unit and to determine the impact of adherence on the rates of ventilator-associated pneumonia. A total of 198 beds were assessed for 60 days using a checklist that consisted of the following items: bed head elevation to 30 to 45º; position of the humidifier filter; lack of fluid in the ventilator circuit; oral hygiene; cuff pressure; and physical therapy. Next, an educational lecture was delivered, and 235 beds were assessed for the following 60 days. Data were also collected on the incidence of ventilator-acquired pneumonia. Adherence to the following ventilator care bundle items increased: bed head elevation from 18.7% to 34.5%; lack of fluid in the ventilator circuit from 55.6% to 72.8%; oral hygiene from 48.5% to 77.8%; and cuff pressure from 29.8% to 51.5%. The incidence of ventilator-associated pneumonia was statistically similar before and after intervention (p=0.389). The educational intervention performed in this study increased the adherence to the ventilator care bundle, but the incidence of ventilator-associated pneumonia did not decrease in the small sample that was assessed.
Kim, Dae-Young; Seo, Byoung-Do; Choi, Pan-Am
2014-04-01
[Purpose] This study was conducted to determine the influence of Taekwondo as security martial arts training on anaerobic threshold, cardiorespiratory fitness, and blood lactate recovery. [Subjects and Methods] Fourteen healthy university students were recruited and divided into an exercise group and a control group (n = 7 in each group). The subjects who participated in the experiment were subjected to an exercise loading test in which anaerobic threshold, value of ventilation, oxygen uptake, maximal oxygen uptake, heart rate, and maximal values of ventilation / heart rate were measured during the exercise, immediately after maximum exercise loading, and at 1, 3, 5, 10, and 15 min of recovery. [Results] At the anaerobic threshold time point, the exercise group showed a significantly longer time to reach anaerobic threshold. The exercise group showed significantly higher values for the time to reach VO2max, maximal values of ventilation, maximal oxygen uptake and maximal values of ventilation / heart rate. Significant changes were observed in the value of ventilation volumes at the 1- and 5-min recovery time points within the exercise group; oxygen uptake and maximal oxygen uptake were significantly different at the 5- and 10-min time points; heart rate was significantly different at the 1- and 3-min time points; and maximal values of ventilation / heart rate was significantly different at the 5-min time point. The exercise group showed significant decreases in blood lactate levels at the 15- and 30-min recovery time points. [Conclusion] The study results revealed that Taekwondo as a security martial arts training increases the maximal oxygen uptake and anaerobic threshold and accelerates an individual's recovery to the normal state of cardiorespiratory fitness and blood lactate level. These results are expected to contribute to the execution of more effective security services in emergencies in which violence can occur.
Thomachot, L; Viviand, X; Arnaud, S; Boisson, C; Martin, C D
1998-11-01
Many heat and moisture exchangers with filter (HMEF) have been developed. In-house data from companies provide some information about their performances; unfortunately, to our knowledge, no comparative evaluation in clinical conditions has been undertaken of these newer products. The aim of this study was to compare the efficiency of two HMEFs, one hydrophobic and one hygroscopic, on humidifying capacity and the rate of bronchial colonization and ventilator-associated pneumonia in ICU patients. Prospective, randomized study. ICU of a university hospital. All patients who required mechanical ventilation for > or = 24 h during the study period. On admission to the ICU, patients were randomly assigned to one of two groups. In one group, the patients were ventilated with a hygroscopic device (Humid-Vent Filter Light HMEF; Gibeck; Upplands Vaesby, Sweden). The condensation surface was made of paper (Microwell) impregnated with CaCl2. The filter membrane was made of polypropylene. In the other group, the patients were ventilated with a hydrophobic device (Pall BB100 HMEF). The condensation surface was made of a hydrophobic resin with a hydrophylic layer. The filter membrane was made of ceramic fibers. In both groups, HMEFs were changed daily. Both groups of patients were similar for the tested characteristics, including parameters of mechanical ventilation. Sixty-six patients were ventilated for 11.7+/-11 days with the Humid-Vent Filter Light HMEF and 70 patients for 12.2+/-12 days with the Pall BB 100. Patients ventilated with the Humid-Vent Filter Light underwent 6.0+/-3.0 tracheal aspirations and 1.7+/-2.0 instillations per day, and those with the Pall BB 100, 6.0+/-3.0 and 1.6+/-2.0 per day, respectively (not significant [NS]). Abundance of tracheal secretions, presence of blood, and viscosity, evaluated by semiquantitative scales, were similar in both groups. No difference in the rate of atelectasis was observed between the two groups (7.5% and 7.1%, NS). One episode of tracheal tube occlusion was observed with the Humid-Vent Filter Light HMEF, and one with the other HMEF (NS). One patient in each group (NS) was switched to an active heated humidifier because of very tenacious bronchial secretions despite repeated instillations. Tracheal colonization was observed at a rate of 67% with the Humid-Vent Filter Light and 58% with the Pall BB 100 (NS). A small, but NS difference was observed in the rate of ventilator-associated pneumonia: Humid-Vent Filter Light, 32% (27.1 per 1000 ventilator days); and Pall BB 100, 37% (30.4 per 1000 ventilator days). Bacteria responsible for tracheal colonization and pneumonia were similar in both groups. Three patients in each group died from their nosocomial pneumonia. Despite differences in their components, the two HMEFs tested achieved similar performances in terms of humidification and heating of inspired gases. Only one episode of endotracheal tube occlusion was detected and very few patients (one in each group) had to be switched to an active heated humidifier. No difference was observed either in the rate of tracheal colonization or of ventilator-associated pneumonia. These data show that the hygroscopic HME (Humid-Vent Filter Light) and the hydrophobic HME (Pall BB 100) are suited for use in ICU patients.
Bench performance of ventilators during simulated paediatric ventilation.
Park, M A J; Freebairn, R C; Gomersall, C D
2013-05-01
This study compares the accuracy and capabilities of various ventilators using a paediatric acute respiratory distress syndrome lung model. Various compliance settings and respiratory rate settings were used. The study was done in three parts: tidal volume and FiO2 accuracy; pressure control accuracy and positive end-expiratory pressure (PEEP) accuracy. The parameters set on the ventilator were compared with either or both of the measured parameters by the test lung and the ventilator. The results revealed that none of the ventilators could consistently deliver tidal volumes within 1 ml/kg of the set tidal volume, and the discrepancy between the delivered volume and the volume measured by the ventilator varied greatly. The target tidal volume was 8 ml/kg, but delivered tidal volumes ranged from 3.6-11.4 ml/kg and the volumes measured by the ventilator ranged from 4.1-20.6 ml/kg. All the ventilators maintained pressure within 20% of the set pressure, except one ventilator which delivered pressures of up to 27% higher than the set pressure. Two ventilators maintained PEEP within 10% of the prescribed PEEP. The majority of the readings were also within 10%. However, three ventilators delivered, at times, PEEPs over 20% higher. In conclusion, as lung compliance decreases, especially in paediatric patients, some ventilators perform better than others. This study highlights situations where ventilators may not be able to deliver, nor adequately measure, set tidal volumes, pressure, PEEP or FiO2.
Duan, Jun; Han, Xiaoli; Bai, Linfu; Zhou, Lintong; Huang, Shicong
2017-02-01
To develop and validate a scale using variables easily obtained at the bedside for prediction of failure of noninvasive ventilation (NIV) in hypoxemic patients. The test cohort comprised 449 patients with hypoxemia who were receiving NIV. This cohort was used to develop a scale that considers heart rate, acidosis, consciousness, oxygenation, and respiratory rate (referred to as the HACOR scale) to predict NIV failure, defined as need for intubation after NIV intervention. The highest possible score was 25 points. To validate the scale, a separate group of 358 hypoxemic patients were enrolled in the validation cohort. The failure rate of NIV was 47.8 and 39.4% in the test and validation cohorts, respectively. In the test cohort, patients with NIV failure had higher HACOR scores at initiation and after 1, 12, 24, and 48 h of NIV than those with successful NIV. At 1 h of NIV the area under the receiver operating characteristic curve was 0.88, showing good predictive power for NIV failure. Using 5 points as the cutoff value, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy for NIV failure were 72.6, 90.2, 87.2, 78.1, and 81.8%, respectively. These results were confirmed in the validation cohort. Moreover, the diagnostic accuracy for NIV failure exceeded 80% in subgroups classified by diagnosis, age, or disease severity and also at 1, 12, 24, and 48 h of NIV. Among patients with NIV failure with a HACOR score of >5 at 1 h of NIV, hospital mortality was lower in those who received intubation at ≤12 h of NIV than in those intubated later [58/88 (66%) vs. 138/175 (79%); p = 0.03). The HACOR scale variables are easily obtained at the bedside. The scale appears to be an effective way of predicting NIV failure in hypoxemic patients. Early intubation in high-risk patients may reduce hospital mortality.
Earnest, G S; Mickelsen, R L; McCammon, J B; O'Brien, D M
1997-11-01
This study modeled the time required for a gasoline-powered, 5 horsepower (hp), 4-cycle engine to generate carbon monoxide (CO) concentrations exceeding the National Institute for Occupational Safety and Health 200-ppm ceiling and 1200-ppm immediately dangerous to life and health concentration for various room sizes and ventilation rates. The model permitted the ambiguous term "well-ventilated area" to be defined. The model was compared with field data collected at a site where two workers were poisoned while operating a 5-hp concrete saw in a bathroom having open doors and an operating ventilation system. There is agreement between both the modeled and field-generated data, indicating that hazardous CO concentrations can develop within minutes. Comparison of field and modeling data showed the measured CO generation rate at approximately one-half of the value used in the model, which may be partially because the engine used in the field was not under load during data collection. The generation rate and room size from the actual poisoning was then used in the model. The model determined that ventilation rates of nearly 5000 ft3/min (120 air changes per hour) would be required to prevent the CO concentration from exceeding the 200-ppm ceiling for short periods. Results suggest that small gasoline-powered engines should not be operated inside of buildings or in semienclosed spaces and that manufacturers of such tools should improve their warnings and develop engineering control options for better user protection.
Caruso, Pedro; Denari, Silvia; Ruiz, Soraia A L; Demarzo, Sergio E; Deheinzelin, Daniel
2009-01-01
To compare the incidence of ventilator-associated pneumonia (VAP) with or without isotonic saline instillation before tracheal suctioning. As a secondary objective, we compared the incidence of endotracheal tube occlusion and atelectasis. Randomized clinical trial. The study was conducted in a medical surgical intensive care unit of an oncologic hospital. We selected consecutive patients needing mechanical ventilation for >72 hrs. Patients were allocated into two groups: a saline group that received instillation of 8 mL of saline before tracheal suctioning and a control group which did not. VAP was diagnosed based on clinical suspicion and confirmed by bronchoalveolar lavage quantitative culture. The incidence of atelectasis on daily chest radiography and endotracheal tube occlusions were recorded. The sample size was calculated to a power of 80% and a type I error probability of 5%. One hundred thirty patients were assigned to the saline group and 132 to the control group. The baseline demographic variables were similar between groups. The rate of clinically suspected VAP was similar in both groups. The incidence of microbiological proven VAP was significantly lower in the saline group (23.5% x 10.8%; p = 0.008) (incidence density/1.000 days of ventilation 21.22 x 9.62; p < 0.01). Using the Kaplan-Meier curve analysis, the proportion of patients remaining without VAP was higher in the saline group (p = 0.02, log-rank test). The relative risk reduction of VAP in the saline instillation group was 54% (95% confidence interval, 18%-74%) and the number needed to treat was eight (95% confidence interval, 5-27). The incidence of atelectases and endotracheal tube occlusion were similar between groups. Instillation of isotonic saline before tracheal suctioning decreases the incidence of microbiological proven VAP.
de Magalhães, Raquel F; Samary, Cynthia S; Santos, Raquel S; de Oliveira, Milena V; Rocha, Nazareth N; Santos, Cintia L; Kitoko, Jamil; Silva, Carlos A M; Hildebrandt, Caroline L; Goncalves-de-Albuquerque, Cassiano F; Silva, Adriana R; Faria-Neto, Hugo C; Martins, Vanessa; Capelozzi, Vera L; Huhle, Robert; Morales, Marcelo M; Olsen, Priscilla; Pelosi, Paolo; de Abreu, Marcelo Gama; Rocco, Patricia R M; Silva, Pedro L
2016-11-25
Variable ventilation has been shown to improve pulmonary function and reduce lung damage in different models of acute respiratory distress syndrome. Nevertheless, variable ventilation has not been tested during pneumonia. Theoretically, periodic increases in tidal volume (V T ) and airway pressures might worsen the impairment of alveolar barrier function usually seen in pneumonia and could increase bacterial translocation into the bloodstream. We investigated the impact of variable ventilation on lung function and histologic damage, as well as markers of lung inflammation, epithelial and endothelial cell damage, and alveolar stress, and bacterial translocation in experimental pneumonia. Thirty-two Wistar rats were randomly assigned to receive intratracheal of Pseudomonas aeruginosa (PA) or saline (SAL) (n = 16/group). After 24-h, animals were anesthetized and ventilated for 2 h with either conventional volume-controlled (VCV) or variable volume-controlled ventilation (VV), with mean V T = 6 mL/kg, PEEP = 5cmH 2 O, and FiO 2 = 0.4. During VV, tidal volume varied randomly with a coefficient of variation of 30% and a Gaussian distribution. Additional animals assigned to receive either PA or SAL (n = 8/group) were not ventilated (NV) to serve as controls. In both SAL and PA, VV improved oxygenation and lung elastance compared to VCV. In SAL, VV decreased interleukin (IL)-6 expression compared to VCV (median [interquartile range]: 1.3 [0.3-2.3] vs. 5.3 [3.6-7.0]; p = 0.02) and increased surfactant protein-D expression compared to NV (2.5 [1.9-3.5] vs. 1.2 [0.8-1.2]; p = 0.0005). In PA, compared to VCV, VV reduced perivascular edema (2.5 [2.0-3.75] vs. 6.0 [4.5-6.0]; p < 0.0001), septum neutrophils (2.0 [1.0-4.0] vs. 5.0 [3.3-6.0]; p = 0.0008), necrotizing vasculitis (3.0 [2.0-5.5] vs. 6.0 [6.0-6.0]; p = 0.0003), and ultrastructural lung damage scores (16 [14-17] vs. 24 [14-27], p < 0.0001). Blood colony-forming-unit (CFU) counts were comparable (7 [0-28] vs. 6 [0-26], p = 0.77). Compared to NV, VCV, but not VV, increased expression amphiregulin, IL-6, and cytokine-induced neutrophil chemoattractant (CINC)-1 (2.1 [1.6-2.5] vs. 0.9 [0.7-1.2], p = 0.025; 12.3 [7.9-22.0] vs. 0.8 [0.6-1.9], p = 0.006; and 4.4 [2.9-5.6] vs. 0.9 [0.8-1.4], p = 0.003, respectively). Angiopoietin-2 expression was lower in VV compared to NV animals (0.5 [0.3-0.8] vs. 1.3 [1.0-1.5], p = 0.01). In this rat model of pneumonia, VV improved pulmonary function and reduced lung damage as compared to VCV, without increasing bacterial translocation.
Bahreini, Rassol; Currie, Robert W
2015-10-01
The objective of this study was to manipulate ventilation rate to characterize interactions between stocks of honey bees (Apis mellifera L.) and ventilation setting on varroa mite (Varroa destructor Anderson and Trueman) mortality in honey bee colonies kept indoors over winter. The first experiment used colonies established from stock selected locally for wintering performance under exposure to varroa (n = 6) and unselected bees (n = 6) to assess mite and bee mortality and levels of carbon dioxide (CO2) and oxygen (O2) in the bee cluster when kept under a simulated winter condition at 5°C. The second experiment, used colonies from selected bees (n = 10) and unselected bees (n = 12) that were exposed to either standard ventilation (14.4 liter/min per hive) or restricted ventilation (0.24 liter/min per hive, in a Plexiglas ventilation chamber) during a 16-d treatment period to assess the influence of restricted air flow on winter mortality rates of varroa mites and honey bees. Experiment 2 was repeated in early, mid-, and late winter. The first experiment showed that under unrestricted ventilation with CO2 concentrations averaging <2% there was no correlation between CO2 and varroa mite mortality when colonies were placed under low temperature. CO2 was negatively correlated with O2 in the bee cluster in both experiments. When ventilation was restricted, mean CO2 level (3.82 ± 0.31%, range 0.43-8.44%) increased by 200% relative to standard ventilation (1.29 ± 0.31%; range 0.09-5.26%) within the 16-d treatment period. The overall mite mortality rates and the reduction in mean abundance of varroa mite over time was greater under restricted ventilation (37 ± 4.2%) than under standard ventilation (23 ± 4.2%) but not affected by stock of bees during the treatment period. Selected bees showed overall greater mite mortality relative to unselected bees in both experiments. Restricting ventilation increased mite mortality, but did not affect worker bee mortality relative to that for colonies under standard ventilation. Restricted ventilation did not affect the overall level of Nosema compared with the control. However, there was an interaction between stock, season, and time of the trial. Unselected stock showed an increase in Nosema over time in the late winter trial that did not occur in the selected stock. In conclusion, these findings suggested that restricted ventilation has potential to suppress varroa mite in overwintering honey bee colonies via a low-cost and environmentally friendly measure. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Li, Xiaojian; Zhong, Xiaomin; Deng, Zhongyuan; Zhang Xuhui; Zhang, Zhi; Zhang, Tao; Tang, Wenbin; Chen, Bib; Liu, Changling; Cao, Wenjuan
2014-08-01
To investigate the effects of lung protective ventilation strategy combined with lung recruitment maneuver on ARDS complicating patients with severe burn. Clinical data of 15 severely burned patients with ARDS admitted to our burn ICU from September 2011 to September 2013 and conforming to the study criteria were analyzed. Right after the diagnosis of acute lung injury/ARDS, patients received mechanical ventilation with lung protective ventilation strategy. When the oxygenation index (OI) was below or equal to 200 mmHg (1 mmHg = 0. 133 kPa), lung recruitment maneuver was performed combining incremental positive end-expiratory pressure. When OI was above 200 mmHg, lung recruitment maneuver was stopped and ventilation with lung protective ventilation strategy was continued. When OI was above 300 mmHg, mechanical ventilation was stopped. Before combining lung recruitment maneuver, 24 h after combining lung recruitment maneuver, and at the end of combining lung recruitment maneuver, variables of blood gas analysis (pH, PaO2, and PaCO2) were obtained by blood gas analyzer, and the OI values were calculated; hemodynamic parameters including heart rate, mean arterial pressure (MAP), central venous pressure (CVP) of all patients and the cardiac output (CO), extravascular lung water index (EVLWI) of 4 patients who received pulse contour cardiac output (PiCCO) monitoring were monitored. Treatment measures and outcome of patients were recorded. Data were processed with analysis of variance of repeated measurement of a single group and LSD test. (1) Before combining lung recruitment maneuver, 24 h after combining lung recruitment maneuver, and at the end of combining lung recruitment maneuver, the levels of PaO2 and OI of patients were respectively (77 ± 8), (113 ± 5), (142 ± 6) mmHg, and (128 ± 12), (188 ± 8), (237 ± 10) mmHg. As a whole, levels of PaO2 and OI changed significantly at different time points (with F values respectively 860. 96 and 842. 09, P values below 0. 01); levels of pH and PaCO2 showed no obvious changes (with F values respectively 0.35 and 3.13, P values above 0.05). (2) Levels of heart rate, MAP, CVP of all patients and CO of 4 patients who received PiCCO monitoring showed no significant changes at different time points (with F values from 0. 13 to 4. 26, P values above 0.05). Before combining lung recruitment maneuver, 24 h after combining lung recruitment maneuver, and at the end of combining lung recruitment maneuver, the EVLWI values of 4 patients who received PiCCO monitoring were respectively (13.5 ± 1.3), (10.2 ± 1.0), (7.0 ± 0.8) mL/kg ( F =117.00, P <0.01). (3) The patients received mechanical ventilation at 2 to 72 h after burn, lasting for 14-32 (21 ± 13) d. At post injury day 3-14 (7 ± 5) d, lung recruitment maneuver was applied for 2-5 (3.0 ± 2.0) d. All 15 patients recovered without other complications. Lung protective ventilation strategy combining lung recruitment maneuver can significantly improve the oxygenation in patients with severe burn complicated with ARDS and may therefore improve the prognosis.
Cox, Helen; Escombe, Rod; McDermid, Cheryl; Mtshemla, Yolanda; Spelman, Tim; Azevedo, Virginia; London, Leslie
2012-01-01
Tuberculosis transmission in healthcare facilities contributes significantly to the TB epidemic, particularly in high HIV settings. Although improving ventilation may reduce transmission, there is a lack of evidence to support low-cost practical interventions. We assessed the efficacy of wind-driven roof turbines to achieve recommended ventilation rates, compared to current recommended practices for natural ventilation (opening windows), in primary care clinic rooms in Khayelitsha, South Africa. Room ventilation was assessed (CO₂ gas tracer technique) in 4 rooms where roof turbines and air-intake grates were installed, across three scenarios: turbine, grate and window closed, only window open, and only turbine and grate open, with concurrent wind speed measurement. 332 measurements were conducted over 24 months. For all 4 rooms combined, median air changes per hour (ACH) increased with wind speed quartiles across all scenarios. Higher median ACH were recorded with open roof turbines and grates, compared to open windows across all wind speed quartiles. Ventilation with open turbine and grate exceeded WHO-recommended levels (60 Litres/second/patient) for 95% or more of measurements in 3 of the 4 rooms; 47% in the remaining room, where wind speeds were lower and a smaller diameter turbine was installed. High room ventilation rates, meeting recommended thresholds, may be achieved using wind-driven roof turbines and grates, even at low wind speeds. Roof turbines and air-intake grates are not easily closed by staff, allowing continued ventilation through colder periods. This simple, low-cost technology represents an important addition to our tools for TB infection control.
Cox, Helen; Escombe, Rod; McDermid, Cheryl; Mtshemla, Yolanda; Spelman, Tim; Azevedo, Virginia; London, Leslie
2012-01-01
Objective Tuberculosis transmission in healthcare facilities contributes significantly to the TB epidemic, particularly in high HIV settings. Although improving ventilation may reduce transmission, there is a lack of evidence to support low-cost practical interventions. We assessed the efficacy of wind-driven roof turbines to achieve recommended ventilation rates, compared to current recommended practices for natural ventilation (opening windows), in primary care clinic rooms in Khayelitsha, South Africa. Methods Room ventilation was assessed (CO2 gas tracer technique) in 4 rooms where roof turbines and air-intake grates were installed, across three scenarios: turbine, grate and window closed, only window open, and only turbine and grate open, with concurrent wind speed measurement. 332 measurements were conducted over 24 months. Findings For all 4 rooms combined, median air changes per hour (ACH) increased with wind speed quartiles across all scenarios. Higher median ACH were recorded with open roof turbines and grates, compared to open windows across all wind speed quartiles. Ventilation with open turbine and grate exceeded WHO-recommended levels (60 Litres/second/patient) for 95% or more of measurements in 3 of the 4 rooms; 47% in the remaining room, where wind speeds were lower and a smaller diameter turbine was installed. Conclusion High room ventilation rates, meeting recommended thresholds, may be achieved using wind-driven roof turbines and grates, even at low wind speeds. Roof turbines and air-intake grates are not easily closed by staff, allowing continued ventilation through colder periods. This simple, low-cost technology represents an important addition to our tools for TB infection control. PMID:22253742
Regenerative Blower for EVA Suit Ventilation Fan
NASA Technical Reports Server (NTRS)
Izenson, Michael G.; Chen, Weibo; Paul, Heather L.
2010-01-01
Portable life support systems in future space suits will include a ventilation subsystem driven by a dedicated fan. This ventilation fan must meet challenging requirements for pressure rise, flow rate, efficiency, size, safety, and reliability. This paper describes research and development that showed the feasibility of a regenerative blower that is uniquely suited to meet these requirements. We proved feasibility through component tests, blower tests, and design analysis. Based on the requirements for the Constellation Space Suit Element (CSSE) Portable Life Support System (PLSS) ventilation fan, we designed the critical elements of the blower. We measured the effects of key design parameters on blower performance using separate effects tests, and used the results of these tests to design a regenerative blower that will meet the ventilation fan requirements. We assembled a proof-of-concept blower and measured its performance at sub-atmospheric pressures that simulate a PLSS ventilation loop environment. Head/flow performance and maximum efficiency point data were used to specify the design and operating conditions for the ventilation fan. We identified materials for the blower that will enhance safety for operation in a lunar environment, and produced a solid model that illustrates the final design. The proof-of-concept blower produced the flow rate and pressure rise needed for the CSSE ventilation subsystem while running at 5400 rpm, consuming only 9 W of electric power using a non-optimized, commercial motor and controller and inefficient bearings. Scaling the test results to a complete design shows that a lightweight, compact, reliable, and low power regenerative blower can meet the performance requirements for future space suit life support systems.
A Stratification Boomerang: Nonlinear Dependence of Deep Southern Ocean Ventilation on PCO2
NASA Astrophysics Data System (ADS)
Galbraith, E. D.; Merlis, T. M.
2014-12-01
Strong correlations between atmospheric CO2, Antarctic temperatures, and marine proxy records have hinted that ventilation of the deep Southern Ocean may have played a central role in the variations of CO2 over glacial-interglacial cycles. One proposition is that, in general, the Southern Ocean ventilates the deep more strongly under higher CO2, due to a change in winds and/or the dominance of thermal stratification in a warm ocean, which weakens ocean biological carbon storage. Here, we explore this idea with a suite of multi-millennial simulations using the GFDL CM2Mc global coupled model. The results are, indeed, consistent with increasing ventilation of the Southern Ocean as pCO2 increases above modern. However, they reveal a surprising twist under low pCO2: increased salinity of the Southern Ocean, due in part to weakening atmospheric moisture transport, actually increases ventilation rate of the deep ocean under low pCO2 as well. This implies that a nadir of Southern Ocean ventilation occurs at intermediate pCO2, which the model estimates as being close to that of the present-day. This is at odds with the interpretation that weak ventilation of the deep Southern Ocean was the unifying coupled mechanism for the glacial pCO2 cycles. Rather, it suggests that factors other than the ventilation rate of the deep Southern Ocean, such as iron fertilization, ecosystem changes, water mass distributions, and sea ice cover, were key players in the glacial-interglacial CO2 changes.
Renuka, MK; Kalaiselvan, MS; Arunkumar, AS
2017-01-01
Background and Aims: Hanging is a frequently used method to attempt suicide in India. There is a lack of data in the Indian population regarding clinical features and outcomes of suicidal hanging. The purpose of this study was to evaluate the factors affecting mortality and morbidity in patients admitted with suicidal hanging to the Intensive Care Unit (ICU). Methods: A 6-year retrospective study of adult patients admitted to the ICU with suicidal hanging was analysed for demographics, mode of hanging, lead time to emergency room (ER) admission, clinical presentation, Acute Physiology and Chronic Health Evaluation II (APACHE II) and Sequential Organ Failure Assessment (SOFA) scores, admission Glasgow coma scale (GCS) and neurological outcomes. The primary outcome was in-hospital mortality rate. Secondary outcomes were hospital length of stay (LOS), ICU-LOS, time for neurological recovery, organ support and duration of mechanical ventilation. Statistical analysis was performed using the Student's t-test for continuous variables and Chi-square test for categorical variables. Results: We analysed data of 106 patients. The median age was 27 years [Interquartile Range (IQR) (22–34)]. The median lead time to ER admission was 1 h [IQR (0.5–1.4)] with median ICU stay of 3 days [IQR (2–4)]. Vasopressors were administered to 27.4% patients. GCS was ≤7 in 65% patients, and 84.9% patients received mechanical ventilation. Mortality rate was 10.3%. Survivors recovered with normal organ function. Conclusion: Suicidal hanging is associated with significant mortality. Admission GCS, APACHE II and 48 h SOFA score were predictors of poor outcome. PMID:28794524
Mueller, Martina; Wagner, Carol L; Annibale, David J; Knapp, Rebecca G; Hulsey, Thomas C; Almeida, Jonas S
2006-03-01
Approximately 30% of intubated preterm infants with respiratory distress syndrome (RDS) will fail attempted extubation, requiring reintubation and mechanical ventilation. Although ventilator technology and monitoring of premature infants have improved over time, optimal extubation remains challenging. Furthermore, extubation decisions for premature infants require complex informational processing, techniques implicitly learned through clinical practice. Computer-aided decision-support tools would benefit inexperienced clinicians, especially during peak neonatal intensive care unit (NICU) census. A five-step procedure was developed to identify predictive variables. Clinical expert (CE) thought processes comprised one model. Variables from that model were used to develop two mathematical models for the decision-support tool: an artificial neural network (ANN) and a multivariate logistic regression model (MLR). The ranking of the variables in the three models was compared using the Wilcoxon Signed Rank Test. The best performing model was used in a web-based decision-support tool with a user interface implemented in Hypertext Markup Language (HTML) and the mathematical model employing the ANN. CEs identified 51 potentially predictive variables for extubation decisions for an infant on mechanical ventilation. Comparisons of the three models showed a significant difference between the ANN and the CE (p = 0.0006). Of the original 51 potentially predictive variables, the 13 most predictive variables were used to develop an ANN as a web-based decision-tool. The ANN processes user-provided data and returns the prediction 0-1 score and a novelty index. The user then selects the most appropriate threshold for categorizing the prediction as a success or failure. Furthermore, the novelty index, indicating the similarity of the test case to the training case, allows the user to assess the confidence level of the prediction with regard to how much the new data differ from the data originally used for the development of the prediction tool. State-of-the-art, machine-learning methods can be employed for the development of sophisticated tools to aid clinicians' decisions. We identified numerous variables considered relevant for extubation decisions for mechanically ventilated premature infants with RDS. We then developed a web-based decision-support tool for clinicians which can be made widely available and potentially improve patient care world wide.
do Canto, Débora Francisco; Almeida, Miriam de Abreu
2013-12-01
This study aimed to validate the results of Nursing selected from the link NANDA-I-NOC (Nursing Outcomes Classification--NANDA--International) for diagnosis Ineffective Breathing Pattern and Impaired Spontaneous Ventilation in adult intensive care unit. This is a content validation study conducted in a university hospital in southern Brazil with 15 expert nurses with clinical experience and knowledge of the ratings. The instruments contained five-point Likert scales to rate the importance of each outcome (1st step) and indicator (Step 2) for the diagnoses studied. We calculated weighted averages for each outcome/indicator, considering) 1 = 0. 2 = 0.25, 3 = 0.50 4 = 0.75 and 5 = 1. The outcomes suggested by the NOC with averages above 0.8 were considered validated as well as the indicators. The results Respiratory State--airway permeability (Ineffective Breathing Patterns) and 11 indicators, and Response to mechanical ventilation: adult (Impaired Spontaneous Ventilation) with 26 indicators were validated.
Effect of residential air-to-air heat and moisture exchangers on indoor humidity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barringer, C.G.; McGugan, C.A.
1989-01-01
A project was undertaken to develop guidelines for the selection of residential heat and moisture recovery ventilation systems (HRVs) in order to maintain an acceptable indoor humidity for various climatic conditions. These guidelines were developed from reviews on ventilation requirements, HRV performance specifications, and from computer modeling. Space conditions within three house/occupancy models for several types of HRV were simulated for three climatic conditions (Lake Charles, LA; Seattle, WA; and Winnipeg, MB) in order to determine the impact of the HRVs on indoor relative humidity and space-conditioning loads. Results show that when reduction of cooling cost is the main consideration,more » exchangers with moisture recovery are preferable to sensible HRVs. For reduction of heating costs, moisture recovery should be done for ventilation rates greater than about 15 L/s and average winter temperatures less than about (minus) 10{degrees}C if internal moisture generation rates are low. For houses with higher ventilation rates and colder average winter temperatures, exchangers with moisture recovery should be used.« less
George E. Myers
1984-01-01
A critical literature review has been carried out on the influence of ventilation rate (N, hr.-1) and board loading (L, m2/m3) on steady state formaldehyde concentrations (Cs, ppm) resulting from particleboard and plywood emissions. Large differences exist among boards in the extent to which their formaldehyde concentrations change with N or L in laboratory chambers....
Thammanomai, Apiradee; Hamakawa, Hiroshi; Bartolák-Suki, Erzsébet; Suki, Béla
2013-01-01
The accepted protocol to ventilate patients with acute lung injury is to use low tidal volume (VT) in combination with recruitment maneuvers or positive end-expiratory pressure (PEEP). However, an important aspect of mechanical ventilation has not been considered: the combined effects of PEEP and ventilation modes on the integrity of the epithelium. Additionally, it is implicitly assumed that the best PEEP-VT combination also protects the epithelium. We aimed to investigate the effects of ventilation mode and PEEP on respiratory mechanics, peak airway pressures and gas exchange as well as on lung surfactant and epithelial cell integrity in mice with acute lung injury. HCl-injured mice were ventilated at PEEPs of 3 and 6 cmH2O with conventional ventilation (CV), CV with intermittent large breaths (CVLB) to promote recruitment, and a new mode, variable ventilation, optimized for mice (VVN). Mechanics and gas exchange were measured during ventilation and surfactant protein (SP)-B, proSP-B and E-cadherin levels were determined from lavage and lung homogenate. PEEP had a significant effect on mechanics, gas exchange and the epithelium. The higher PEEP reduced lung collapse and improved mechanics and gas exchange but it also down regulated surfactant release and production and increased epithelial cell injury. While CVLB was better than CV, VVN outperformed CVLB in recruitment, reduced epithelial injury and, via a dynamic mechanotransduction, it also triggered increased release and production of surfactant. For long-term outcome, selection of optimal PEEP and ventilation mode may be based on balancing lung physiology with epithelial injury. PMID:23326543
Effect of acute kidney injury on weaning from mechanical ventilation in critically ill patients.
Vieira, José M; Castro, Isac; Curvello-Neto, Américo; Demarzo, Sérgio; Caruso, Pedro; Pastore, Laerte; Imanishe, Marina H; Abdulkader, Regina C R M; Deheinzelin, Daniel
2007-01-01
Acute kidney injury (AKI) worsens outcome in various scenarios. We sought to investigate whether the occurrence of AKI has any effect on weaning from mechanical ventilation. Observational, retrospective study in a 23-bed medical/surgical intensive care unit (ICU) in a cancer hospital from January to December 2003. The inclusion criterion was invasive mechanical ventilation for > or =48 hrs. AKI was defined as at least one measurement of serum creatinine of > or =1.5 mg/dL during the ICU stay. Patients were then separated into AKI and non-AKI patients (control group). The criterion for weaning was the combination of positive end-expiratory pressure of < or =8 cm H2O, pressure support of < or =10 cm H2O, and Fio2 of < or =0.4, with spontaneous breathing. The primary end point was duration of weaning and the secondary end points were rate of weaning failure, total length of mechanical ventilation, length of stay in the ICU, and ICU mortality. A total of 140 patients were studied: 93 with AKI and 47 controls. The groups were similar in regard to age, sex, and type of tumor. Diagnosis of acute lung injury/acute respiratory distress syndrome as cause of respiratory failure and Simplified Acute Physiology Score II at admission did not differ between groups. During ICU stay, AKI patients had markers of more severe disease: increased occurrence of severe sepsis or septic shock, higher number of antibiotics, and longer use of vasoactive drugs. The median (interquartile range) duration of mechanical ventilation (10 [6-17] vs. 7 [2-12] days, p = .017) and duration of weaning from mechanical ventilation (41 [16-97] vs. 21 [7-33.5] hrs, p = .018) were longer in AKI patients compared with control patients. Cox regression analysis demonstrated that a > or =85% increase in baseline serum creatinine (hazard rate, 2.30; 95% confidence interval, 1.30-4.08), oliguria (hazard rate, 2.51; 95% confidence interval, 1.24-5.08), and the number of antibiotics (hazard rate, 2.64; 95% confidence interval, 1.51-4.63) predicted longer duration of weaning. The length of ICU stay and ICU mortality rate were significantly greater in the AKI patients. After adjusting for Simplified Acute Physiology Score II, oliguria (odds ratio, 30.8; 95% confidence interval, 7.7-123.0) remained as a strong risk factor for mortality. This study shows that renal dysfunction has serious consequences in the duration of mechanical ventilation, weaning from mechanical ventilation, and mortality in critically ill cancer patients.
Moreau, Anne-Sophie; Martin-Loeches, Ignacio; Povoa, Pedro; Salluh, Jorge; Rodriguez, Alejandro; Thille, Arnaud W; Diaz Santos, Emilio; Vedes, Elisa; Lobo, Suzana Margareth; Mégarbane, Bruno; Molero Silvero, Esperanza; Coelho, Luis; Argaud, Laurent; Sanchez Iniesta, Rafael; Labreuche, Julien; Rouzé, Anahita; Nseir, Saad
2018-03-01
The aim of this planned analysis of the prospective multinational TAVeM database was to determine the incidence, aetiology and impact on outcome of ventilator-associated lower respiratory tract infections (VA-LRTI) in immunocompromised patients.All patients receiving mechanical ventilation for >48 h were included. Immunocompromised patients (n=663) were compared with non-immunocompromised patients (n=2297).The incidence of VA-LRTI was significantly lower among immunocompromised than among non-immunocompromised patients (16.6% versus 24.2%; sub-hazard ratio 0.65, 95% CI 0.53-0.80; p<0.0001). Similar results were found regarding ventilator-associated tracheobronchitis (7.3% versus 11.6%; sub-hazard ratio 0.61, 95% CI 0.45-0.84; p=0.002) and ventilator-associated pneumonia (9.3% versus 12.7%; sub-hazard ratio 0.72, 95% CI 0.54-0.95; p=0.019). Among patients with VA-LRTI, the rates of multidrug-resistant bacteria (72% versus 59%; p=0.011) and intensive care unit mortality were significantly higher among immunocompromised than among non-immunocompromised patients (54% versus 30%; OR 2.68, 95% CI 1.78-4.02; p<0.0001). In patients with ventilator-associated pneumonia, mortality rates were higher among immunocompromised than among non-immunocompromised patients (64% versus 34%; p<0.001).Incidence of VA-LRTI was significantly lower among immunocompromised patients, but it was associated with a significantly higher mortality rate. Multidrug-resistant pathogens were more frequently found in immunocompromised patients with VA-LRTI. Copyright ©ERS 2018.
Pizza, Alessandro; Picconi, Enzo; Piastra, Marco; Genovese, Orazio; Biasucci, Daniele G; Conti, Giorgio
2017-08-01
The aim of this study is to examine the clinical data of children who underwent tracheostomy during their stay in Pediatric Intensive Care Unit (PICU), in order to describe the relationship between the timing of tracheostomy, the length of PICU stay and the occurrence of ventilator-associated pneumonia (VAP). This is a retrospective cohort study that collects all patients undergoing tracheostomy during their PICU stay over a six-year period. Data collection included PICU length of stay, days of intubation, days of mechanical ventilation, primary indication for tracheostomy, information about VAP and decannulations. The early tracheostomy group was defined as patients who had ten or fewer days of continuous ventilation, whereas the late tracheostomy group had more than ten days of continuous ventilation. A significant decrease in the rate of VAP incidence was noticed in the early tracheostomy group vs. late group (P=0.004, OR=0.39, 95% CI: 0.18-0.85). No differences were observed about decannulation, need of long-term ventilation and death rate. Significant decreases of days of mechanical ventilation and PICU stay were found in subgroup of patients who underwent early tracheostomy and were decannulated within 18 months. No standard timing for tracheostomy placement has been established in the pediatric population. Early tracheostomy can shorten the days of ventilation and hospitalization in PICU and reduce the incidence of VAP, but further studies are needed to identify patient categories in which it can be of benefit.
Three-year experience with neonatal ventilation from a tertiary care hospital in Delhi.
Singh, M; Deorari, A K; Paul, V K; Mittal, M; Shanker, S; Munshi, U; Jain, Y
1993-06-01
Ninety neonates were ventilated over a period of 33 months of whom 50 (55.5%) survived. Fifty seven babies received IPPV while 33 CPAP. IPPV mode was being used more frequently recently and survival rates have steadily improved over past 3 years. Survival was cent per cent in babies above 1.5 kg on CPAP mode while 16/26 (57.7%) survived on IPPV mode. Of 22 extremely VLBW (< 1 kg) babies, six survived. HMD was the commonest indication of ventilation (50%), of which 53% (24/45) survived. The other important indications of ventilation were apnea in 13 and transient tachypnea in 11 babies. All babies requiring ventilation for transient tachypnea survived. Nosocomial infections were common in association with ventilation 34/90 (37.7%), out of which in 14 was responsible for about a third of deaths. Pulmonary air leaks developed in 12 babies of which 6 died. Two babies developed BPD and one ROP. Neonatal ventilation should be ventured in centres where basic facilities for level II care already exist. It may not be cost effective to ventilate extremely low birth weight neonates.
Starmer, John; Giuse, Dario
2008-01-01
Care of mechanically ventilated patients requires coordination between multiple caregivers, necessitating the availability of accurate and timely information on patient status. Researchers have documented positive effects of several interventions on the rates of developing ventilator associated complications, such as providing regular oral care and elevating the head of the bed. Informatics tools, such as electronic whiteboards, reminders, and alerts have been shown to aid in clinician compliance with guidelines or protocols. The purpose of this project was to design and implement a real-time ventilator management dashboard to show patient status with respect to elements important for ventilator management and infection prevention in the adult Intensive Care Units at Vanderbilt University Medical Center. PMID:18998939
Resnick, Portia B
2016-03-01
Postexercise massage can be used to help promote recovery from exercise on the cellular level, as well as systemically by increasing parasympathetic activity. No studies to date have been done to assess the effects of massage on postexercise metabolic changes, including excess postexercise oxygen consumption (EPOC). The purpose of this study was to compare the effects of massage recovery and resting recovery on a subject's heart rate variability and selected metabolic effects following a submaximal treadmill exercise session. One healthy 24-year-old female subject performed 30 minutes of submaximal treadmill exercise prior to resting or massage recovery sessions. Metabolic data were collected throughout the exercise sessions and at three 10 minute intervals postexercise. Heart rate variability was evaluated for 10 minutes after each of two 30-minute recovery sessions, either resting or massage. Heart rate returned to below resting levels (73 bpm) with 30 and 60 minutes of massage recovery (72 bpm and 63 bpm, respectively) compared to 30 and 60 minutes of resting recovery (77 bpm and 74 bpm, respectively). Heart rate variability data showed a more immediate shift to the parasympathetic state following 30 minutes of massage (1.152 LF/HF ratio) versus the 30-minute resting recovery (6.91 LF/HF ratio). It took 60 minutes of resting recovery to reach similar heart rate variability levels (1.216 LF/HF) found after 30 minutes of massage. Ventilations after 30 minutes of massage recovery averaged 7.1 bpm compared to 17.9 bpm after 30 minutes of resting recovery. No differences in EPOC were observed through either the resting or massage recovery based on the metabolic data collected. Massage was used to help the subject shift into parasympathetic activity more quickly than rest alone following a submaximal exercise session.
Aerodynamic characteristics of the ventilated design for flapping wing micro air vehicle.
Zhang, G Q; Yu, S C M
2014-01-01
Inspired by superior flight performance of natural flight masters like birds and insects and based on the ventilating flaps that can be opened and closed by the changing air pressure around the wing, a new flapping wing type has been proposed. It is known that the net lift force generated by a solid wing in a flapping cycle is nearly zero. However, for the case of the ventilated wing, results for the net lift force are positive which is due to the effect created by the "ventilation" in reducing negative lift force during the upstroke. The presence of moving flaps can serve as the variable in which, through careful control of the areas, a correlation with the decrease in negative lift can be generated. The corresponding aerodynamic characteristics have been investigated numerically by using different flapping frequencies and forward flight speeds.
Are there benefits or harm from pressure targeting during lung-protective ventilation?
MacIntyre, Neil R; Sessler, Curtis N
2010-02-01
Mechanically, breath design is usually either flow/volume-targeted or pressure-targeted. Both approaches can effectively provide lung-protective ventilation, but they prioritize different ventilation parameters, so their responses to changing respiratory-system mechanics and patient effort are different. These different response behaviors have advantages and disadvantages that can be important in specific circumstances. Flow/volume targeting guarantees a set minute ventilation but sometimes may be difficult to synchronize with patient effort, and it will not limit inspiratory pressure. In contrast, pressure targeting, with its variable flow, may be easier to synchronize and will limit inspiratory pressure, but it provides no control over delivered volume. Skilled clinicians can maximize benefits and minimize problems with either flow/volume targeting or pressure targeting. Indeed, as is often the case in managing complex life-support devices, it is operator expertise rather than the device design features that most impacts patient outcomes.
Remetti, R; Gigante, G E
2010-01-01
The study presents the results of a campaign of measurements on the daily radon concentration using a Genitron Alpha Guard spectrometer. All the measurements have been intended to highlight the radon concentration variability during the 24 hours of the day and trying to find correlations with other ambient parameters such as temperature and pressure or local conditions such as the presence or not of a forced ventilation system. The main part of the measurements have been carried in the area of the Nuclear Measurement Laboratory of the Department of Basic and Applied Sciences for Engineering of "Sapienza" University of Rome. Results show a rapid rise of radon concentration in the night, when the artificial ventilation system was off and with door and windows closed. In the morning, after the opening of door and windows, the concentration falls down abruptly. With artificial ventilation system in function concentration never reaches significant values.
Assessment of Natural Ventilation System for a Typical Residential House in Poland
NASA Astrophysics Data System (ADS)
Antczak-Jarząbska, Romana; Krzaczek, Marek
2016-09-01
The paper presents the research results of field measurements campaign of natural ventilation performance and effectiveness in a residential building. The building is located in the microclimate whose parameters differ significantly in relation to a representative weather station. The measurement system recorded climate parameters and the physical variables characterizing the air flow in the rooms within 14 days of the winter season. The measurement results showed that in spite of proper design and construction of the ventilation system, unfavorable microclimatic conditions that differed from the predicted ones caused significant reduction in the efficiency of the ventilation system. Also, during some time periods, external climate conditions caused an opposite air flow direction in the vent inlets and outlets, leading to a significant deterioration of air quality and thermal comfort measured by CO2 concentration and PMV index in a residential area.
Sancho, Jesus; Servera, Emilio; Morelot-Panzini, Capucine; Salachas, François; Similowski, Thomas; Gonzalez-Bermejo, Jesus
2014-03-01
Non-invasive ventilation (NIV) prolongs survival in amyotrophic lateral sclerosis (ALS), but there are no data with which to compare the effectiveness of the different ventilator modes - volume (Vol-NIV) or pressure-cycled (Pres-NIV) ventilation - in ALS. We aimed to determine whether the ventilatory mode has an effect on ventilation effectiveness and survival of ALS patients using NIV. We used a retrospective study that included all ALS patients for whom NIV was indicated in two referral units: one using Vol-NIV and the other using Pres-NIV. Demographic, functional and nocturnal gas exchange parameters at NIV initiation were recorded. Eighty-two ALS patients ventilated using Pres-NIV and 62 using Vol-NIV were included. No differences were found in survival from NIV initiation between Vol-NIV (median 15.00 (7.48-22.41) months) and Pres-NIV (median 15.00 (10.25-19.75) months, p = 0.533) patients. Effective NIV was achieved in 72.41% Vol-NIV patients and in 48.78% Pres-NIV patients (p < 0.001). Ventilator mode (OR 12.066 (4.251-32.270), p < 0.001) and severity of bulbar dysfunction (OR 1.07 (1.011-1.133), p = 0.02) were the variables correlated with effective NIV. In conclusion, although Vol-NIV provides more effective ventilation, Vol-NIV and Pres-NIV present similar survival in ALS. Effectiveness of NIV is related to the severity of bulbar dysfunction.
NASA Technical Reports Server (NTRS)
Oliva-Buisson, Yvette J. (Compiler)
2014-01-01
The overall objective for this project is to evaluate two candidate alternatives for the existing Propellant Handler's Ensemble (PHE) escape ventilator. The new candidate ventilators use newer technology with similar quantities of air at approximately half the weight of the current ventilator. Ventilators are typically used to ingress/egress a hazardous work area when hard line air is provided at the work area but the hose is not long enough to get the operator to and from the staging area to the work area. The intent of this test is to verify that the new ventilators perform as well as or better than the current ventilators in maintaining proper oxygen (O2) and carbon dioxide (CO2) levels in the PHE during a typical use for the rated time period (10 minutes). We will evaluate two new units comparing them to the existing unit. Subjects will wear the Category I version of the Propellant Handler's Ensemble with the rear suit pouch snapped.
Zhu, Jian Hua; Lee, Heow Pueh; Lim, Kian Meng; Gordon, Bruce R; Wang, De Yun
2012-08-15
We evaluated, by CFD simulation, effects of accessory ostium (AO) on maxillary sinus ventilation. A three-dimensional nasal model was constructed from an adult CT scan with two left maxillary AOs (sinus I) and one right AO (sinus II), then compared to an identical control model with all AOs sealed (sinuses III and IV). Transient simulations of quiet inspiration and expiration at 15 L/min, and nasal blow at 48 L/min, were calculated for both models using low-Reynolds-number turbulent analysis. At low flows, ventilation rates in sinuses with AOs (I ≈ 0.46 L/min, II ≈ 0.54 L/min), were both more than a magnitude higher than sinuses without AOs (II I ≈ 0.019 L/min, IV ≈ 0.020 L/min). Absence of AO almost completely prevented sinus ventilation. Increased ventilation of sinuses with AOs is complex. Under high flow conditions mimicking nose blowing, in sinuses II, III, and IV, the sinus flow rate increased. In contrast, the airflow direction through sinus I reversed between inspiration and expiration, while it remained almost constant throughout the respiration cycle in sinus II. CFD simulation demonstrated that AOs markedly increase maxillary sinus airflow rates and alter sinus air circulation patterns. Whether these airflow changes impact maxillary sinus physiology or pathophysiology is unknown. Copyright © 2012 Elsevier B.V. All rights reserved.
Mansell, Stephanie K; Cutts, Steven; Hackney, Isobel; Wood, Martin J; Hawksworth, Kevin; Creer, Dean D; Kilbride, Cherry; Mandal, Swapna
2018-01-01
Introduction Ventilation parameter data from patients receiving home mechanical ventilation can be collected via secure data cards and modem technology. This can then be reviewed by clinicians and ventilator prescriptions adjusted. Typically available measures include tidal volume (VT), leak, respiratory rate, minute ventilation, patient triggered breaths, achieved pressures and patient compliance. This study aimed to assess the potential impact of ventilator data downloads on management of patients requiring home non-invasive ventilation (NIV). Methods A longitudinal within-group design with repeated measurements was used. Baseline ventilator data were downloaded, reviewed and adjustments made to optimise ventilation. Leak, VT and compliance data were collected for comparison at the first review and 3–7 weeks later. Ventilator data were monitored and amended remotely via a modem by a consultant physiotherapist between the first review and second appointment. Results Analysis of data from 52 patients showed increased patient compliance (% days used >4 hours) from 90% to 96% (p=0.007), increased usage from 6.53 to 6.94 hours (p=0.211) and a change in VT(9.4 vs 8.7 mL/kg/ideal body weight, p=0.022). There was no change in leak following review of NIV prescriptions (mean (SD): 43 (23.4) L/min vs 45 (19.9)L/min, p=0.272). Conclusion Ventilator data downloads, via early remote assessment, can help optimise patient ventilation through identification of modifiable factors, in particular interface leak and ventilator prescriptions. However, a prospective study is required to assess whether using ventilator data downloads provides value in terms of patient outcomes and cost-effectiveness. The presented data will help to inform the design of such a study. PMID:29531743
Model-based setting of inspiratory pressure and respiratory rate in pressure-controlled ventilation.
Schranz, C; Becher, T; Schädler, D; Weiler, N; Möller, K
2014-03-01
Mechanical ventilation carries the risk of ventilator-induced-lung-injury (VILI). To minimize the risk of VILI, ventilator settings should be adapted to the individual patient properties. Mathematical models of respiratory mechanics are able to capture the individual physiological condition and can be used to derive personalized ventilator settings. This paper presents model-based calculations of inspiration pressure (pI), inspiration and expiration time (tI, tE) in pressure-controlled ventilation (PCV) and a retrospective evaluation of its results in a group of mechanically ventilated patients. Incorporating the identified first order model of respiratory mechanics in the basic equation of alveolar ventilation yielded a nonlinear relation between ventilation parameters during PCV. Given this patient-specific relation, optimized settings in terms of minimal pI and adequate tE can be obtained. We then retrospectively analyzed data from 16 ICU patients with mixed pathologies, whose ventilation had been previously optimized by ICU physicians with the goal of minimization of inspiration pressure, and compared the algorithm's 'optimized' settings to the settings that had been chosen by the physicians. The presented algorithm visualizes the patient-specific relations between inspiration pressure and inspiration time. The algorithm's calculated results highly correlate to the physician's ventilation settings with r = 0.975 for the inspiration pressure, and r = 0.902 for the inspiration time. The nonlinear patient-specific relations of ventilation parameters become transparent and support the determination of individualized ventilator settings according to therapeutic goals. Thus, the algorithm is feasible for a variety of ventilated ICU patients and has the potential of improving lung-protective ventilation by minimizing inspiratory pressures and by helping to avoid the build-up of clinically significant intrinsic positive end-expiratory pressure.
Academic Emergency Medicine Physicians' Knowledge of Mechanical Ventilation.
Wilcox, Susan R; Strout, Tania D; Schneider, Jeffrey I; Mitchell, Patricia M; Smith, Jessica; Lutfy-Clayton, Lucienne; Marcolini, Evie G; Aydin, Ani; Seigel, Todd A; Richards, Jeremy B
2016-05-01
Although emergency physicians frequently intubate patients, management of mechanical ventilation has not been emphasized in emergency medicine (EM) education or clinical practice. The objective of this study was to quantify EM attendings' education, experience, and knowledge regarding mechanical ventilation in the emergency department. We developed a survey of academic EM attendings' educational experiences with ventilators and a knowledge assessment tool with nine clinical questions. EM attendings at key teaching hospitals for seven EM residency training programs in the northeastern United States were invited to participate in this survey study. We performed correlation and regression analyses to evaluate the relationship between attendings' scores on the assessment instrument and their training, education, and comfort with ventilation. Of 394 EM attendings surveyed, 211 responded (53.6%). Of respondents, 74.5% reported receiving three or fewer hours of ventilation-related education from EM sources over the past year and 98 (46%) reported receiving between 0-1 hour of education. The overall correct response rate for the assessment tool was 73.4%, with a standard deviation of 19.9. The factors associated with a higher score were completion of an EM residency, prior emphasis on mechanical ventilation during one's own residency, working in a setting where an emergency physician bears primary responsibility for ventilator management, and level of comfort with managing ventilated patients. Physicians' comfort was associated with the frequency of ventilator changes and EM management of ventilation, as well as hours of education. EM attendings report caring for mechanically ventilated patients frequently, but most receive fewer than three educational hours a year on mechanical ventilation, and nearly half receive 0-1 hour. Physicians' performance on an assessment tool for mechanical ventilation is most strongly correlated with their self-reported comfort with mechanical ventilation.
NASA Technical Reports Server (NTRS)
Kuznetz, L. H.
1976-01-01
Test data and a mathematical model of the human thermoregulatory system were used to investigate control of thermal balance by means of a liquid circulating garment (LCG). The test data were derived from five series of experiments in which environmental and metabolic conditions were varied parametrically as a function of several independent variables, including LCG flowrate, LCG inlet temperature, net environmental heat exchange, surrounding gas ventilation rate, ambient pressure, metabolic rate, and subjective/obligatory cooling control. The resultant data were used to relate skin temperature to LCG water temperature and flowrate, to assess a thermal comfort band, to demonstrate the relationship between metabolic rate and LCG heat dissipation, and so forth. The usefulness of the mathematical model as a tool for data interpretation and for generation of trends and relationships among the various physiological parameters was also investigated and verified.
Schatzel, S J; Krog, R B; Dougherty, H
2017-01-01
Longwall face ventilation is an important component of the overall coal mine ventilation system. Increased production rates due to higher-capacity mining equipment tend to also increase methane emission rates from the coal face, which must be diluted by the face ventilation. Increases in panel length, with some mines exceeding 6,100 m (20,000 ft), and panel width provide additional challenges to face ventilation designs. To assess the effectiveness of current face ventilation practices at a study site, a face monitoring study with continuous monitoring of methane concentrations and automated recording of longwall shearer activity was combined with a tracer gas test on a longwall face. The study was conducted at a U.S. longwall mine operating in a thick, bituminous coal seam and using a U-type, bleederless ventilation system. Multiple gob gas ventholes were located near the longwall face. These boreholes had some unusual design concepts, including a system of manifolds to modify borehole vacuum and flow and completion depths close to the horizon of the mined coalbed that enabled direct communication with the mine atmosphere. The mine operator also had the capacity to inject nitrogen into the longwall gob, which occurred during the monitoring study. The results show that emission rates on the longwall face showed a very limited increase in methane concentrations from headgate to tailgate despite the occurrence of methane delays during monitoring. Average face air velocities were 3.03 m/s (596 fpm) at shield 57 and 2.20 m/s (433 fpm) at shield 165. The time required for the sulfur hexafluoride (SF 6 ) peak to occur at each monitoring location has been interpreted as being representative of the movement of the tracer slug. The rate of movement of the slug was much slower in reaching the first monitoring location at shield 57 compared with the other face locations. This lower rate of movement, compared with the main face ventilation, is thought to be the product of a flow path within and behind the shields that is moving in the general direction of the headgate to the tailgate. Barometric pressure variations were pronounced over the course of the study and varied on a diurnal basis.
Automated Control of Endotracheal Tube Cuff Pressure During Simulated Flight
2016-06-01
ventilator, while the other two devices are stand-alone products. The fourth group of ETTs had the cuff pressure measured by the respiratory ...Maquet, Rastatt, Germany). To simulate a clinical environment, each model was ventilated using ventilator settings of respiratory rate of 12...rapidly changes with descent to below 10 cmH2O, allowing fluid above the cuff to readily move into the lower respiratory tract. As with ascent
George E. Myers; Muneo Nagaoka
1981-01-01
Dynamic tests for determining the formaldehyde emission behavior of UF-bonded boards involve the measurement of formaldehyde concentration in the air within a vessel which contains a specified board loading L (m2 of board area per m3 of vessel free volume) and is being ventilated at a specified air exchange rate N (hr.-1). Such tests constitute a primary...
Defense Coastal/Estuarine Research Program (DCERP1)
2013-05-10
also showed that the greater the mixing height and ventilation rate, the lower the PM2.5 concentrations, which points to the diluting effect of these... ventilation rate, the lower the resulting PM2.5 concentrations, which points to the diluting effects of these parameters on ambient PM2.5 concentration...and discharge (New River, tributary creeks) Chemistry: Nutrients, salinity, pH, oxygen , temperature (New River, NRE, tributary creeks) Sedimentology
Cost-benefit analysis of different air change rates in an operating room environment.
Gormley, Thomas; Markel, Troy A; Jones, Howard; Greeley, Damon; Ostojic, John; Clarke, James H; Abkowitz, Mark; Wagner, Jennifer
2017-12-01
Hospitals face growing pressure to meet the dual but often competing goals of providing a safe environment while controlling operating costs. Evidence-based data are needed to provide insight for facility management practices to support these goals. The quality of the air in 3 operating rooms was measured at different ventilation rates. The energy cost to provide the heating, ventilation, and air conditioning to the rooms was estimated to provide a cost-benefit comparison of the effectiveness of different ventilation rates currently used in the health care industry. Simply increasing air change rates in the operating rooms tested did not necessarily provide an overall cleaner environment, but did substantially increase energy consumption and costs. Additionally, and unexpectedly, significant differences in microbial load and air velocity were detected between the sterile fields and back instrument tables. Increasing the ventilation rates in operating rooms in an effort to improve clinical outcomes and potentially reduce surgical site infections does not necessarily provide cleaner air, but does typically increase operating costs. Efficient distribution or management of the air can improve quality indicators and potentially reduce the number of air changes required. Measurable environmental quality indicators could be used in lieu of or in addition to air change rate requirements to optimize cost and quality for an operating room and other critical environments. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Ventilation via Cut Nasotracheal Tube During General Anesthesia
Asahi, Yoshinao; Omichi, Shiro; Adachi, Seita; Kagamiuchi, Hajime; Kotani, Junichiro
2013-01-01
Many patients with disabilities need recurrent dental treatment under general anesthesia because of high caries prevalence and the nature of dental treatment. We evaluated the use of a nasal device as a possible substitute for flexible laryngeal mask airway to reduce the risk of unexpected failure accompanying intubation; we succeeded in ventilating the lungs with a cut nasotracheal tube (CNT) with its tip placed in the pharynx. We hypothesized that this technique would be useful during dental treatment under general anesthesia and investigated its usefulness as part of a minimally invasive technique. A prospective study was designed using general anesthesia in 37 dental patients with disabilities such as intellectual impairment, autism, and cerebral palsy. CNT ventilation was compared with mask ventilation with the patient in 3 positions: the neck in flexion, horizontal position, and in extension. The effect of mouth gags was also recorded during CNT ventilation. The percentages of cases with effective ventilation were similar for the 2 techniques in the neck extension and horizontal positions (89.2–97.3%). However, CNT ventilation was significantly more effective than mask ventilation in the neck flexion position (94.6 vs 45.9%; P < .0001). Mouth gags slightly reduced the rate of effective ventilation in the neck flexion position. Most dental treatments involving minor oral surgeries were performed using mouth gags during CNT ventilation. CNT ventilation was shown to be superior to mask ventilation and is useful during dental treatment under general anesthesia. PMID:23506278
Bédard, Marie-Eve; McKim, Douglas A
2016-10-01
Noninvasive ventilation (NIV) is commonly used to provide ventilatory support for individuals with amyotrophic lateral sclerosis (ALS). Once 24-h ventilation is required, the decision between invasive tracheostomy ventilation and palliation is often faced. This study describes the use and outcomes of daytime mouthpiece ventilation added to nighttime mask ventilation for continuous NIV in subjects with ALS as an effective alternative. This was a retrospective study of 39 subjects with ALS using daytime mouthpiece ventilation over a 17-y period. Thirty-one subjects were successful with mouthpiece ventilation, 2 were excluded, 2 stopped because of lack of motivation, and 4 with bulbar subscores of the Revised Amyotrophic Lateral Sclerosis Functional Rating Scale (b-ALSFRS-R) between 0 and 3 physically failed to use it consistently. No subject in the successful group had a b-ALSFRS-R score of <6. Thirty of the successful subjects were able to generate a maximum insufflation capacity - vital capacity difference with lung volume recruitment. The median (range) survival to tracheostomy or death from initiation of nocturnal NIV and mouthpiece ventilation were 648 (176-2,188) and 286 (41-1,769) d, respectively. Peak cough flow with lung-volume recruitment >180 L/min at initiation of mouthpiece ventilation was associated with a longer survival (637 ± 468 vs 240 ± 158 d (P = .01). Mouthpiece ventilation provides effective ventilation and prolonged survival for individuals with ALS requiring full-time ventilatory support and maintaining adequate bulbar function. Copyright © 2016 by Daedalus Enterprises.
Predictive model for CO2 generation and decay in building envelopes
NASA Astrophysics Data System (ADS)
Aglan, Heshmat A.
2003-01-01
Understanding carbon dioxide generation and decay patterns in buildings with high occupancy levels is useful to identify their indoor air quality, air change rates, percent fresh air makeup, occupancy pattern, and how a variable air volume system to off-set undesirable CO2 level can be modulated. A mathematical model governing the generation and decay of CO2 in building envelopes with forced ventilation due to high occupancy is developed. The model has been verified experimentally in a newly constructed energy efficient healthy house. It was shown that the model accurately predicts the CO2 concentration at any time during the generation and decay processes.
Chang, Ya-Chun; Huang, Kuo-Tung; Chen, Yu-Mu; Wang, Chin-Chou; Wang, Yi-Hsi; Tseng, Chia-Cheng; Lin, Meng-Chih; Fang, Wen-Feng
2018-04-04
We intended to develop a scoring system to predict mechanical ventilator dependence in patients who survive sepsis/septic shock with respiratory failure. This study evaluated 251 adult patients in medical intensive care units (ICUs) between August 2013 to October 2015, who had survived for over 21 days and received aggressive treatment. The risk factors for ventilator dependence were determined. We then constructed a ventilator dependence (VD) risk score using the identified risk factors. The ventilator dependence risk score was calculated as the sum of the following four variables after being adjusted by proportion to the beta coefficient. We assigned a history of previous stroke, a score of one point, platelet count less than 150,000/μL a score of one point, pH value less than 7.35 a score of two points, and the fraction of inspired oxygen on admission day 7 over 39% as two points. The area under the curve in the derivation group was 0.725 (p < 0.001). We then applied the VD risk score for validation on 175 patients. The area under the curve in the validation group was 0.658 (p = 0.001). VD risk score could be applied to predict prolonged mechanical ventilation in patients who survive sepsis/septic shock.
Nakano, Shintaro; Kasai, Takatoshi; Tanno, Jun; Sugi, Keiki; Sekine, Yasumasa; Muramatsu, Toshihiro; Senbonmatsu, Takaaki; Nishimura, Shigeyuki
2015-08-01
Adaptive servo-ventilation has a potential sympathoinhibitory effect in acute cardiogenic pulmonary oedema (ACPO). To evaluate the acute effects of adaptive servo-ventilation in patients with ACPO. Fifty-eight consecutive patients with ACPO were divided into those who underwent adaptive servo-ventilation and those who received oxygen therapy alone as part of their immediate care. Visual analogue scale, vital signs, blood gas data and plasma catecholamine concentrations at baseline and 1 h during emergency care, and subsequent clinical events (death within 30 days, intubation within seven days or between seven and 30 days, and length of hospital stay) were assessed. Pre-matched and post-propensity score (PS)-matched datasets were analysed. During the first hour of adaptive servo-ventilation, plasma catecholamine concentrations fell significantly (baseline versus 1 h: epinephrine p = 0.003, norepinephrine p < 0.001, dopamine p < 0.001), with falls in blood pressure, heart rate, respiratory rate and pCO2, and rise in HCO3 and pH. In the PS-matched model, visual analogue scale (p = 0.036), systolic blood pressure (from 153.8 ± 30.7 to 133.1 ± 16.3 mmHg; p = 0.025) and plasma dopamine concentration (p = 0.034) fell significantly in the adaptive servo-ventilation group compared with the oxygen therapy alone group. The clinical outcomes between the groups were comparable. In patients with ACPO, emergency care using adaptive servo-ventilation attenuated plasma catecholamine concentrations and led to the improvement of dyspnoea, vital signs and acid-base balance, without adversely influencing clinical outcomes. Using adaptive servo-ventilation, rather than standard oxygen alone, may relieve dyspnoea and improve haemodynamic status, possibly by modulating sympathetic nerve activity. © The European Society of Cardiology 2014.
Respiratory support in oncology ward setting: a prospective descriptive study.
Mishra, Seema; Bhatnagar, Sushma; Gupta, Deepak; Goyal, Gaurav Nirvani; Agrawal, Ravi; Jain, Roopesh; Chauhan, Himanshu
2009-01-01
Mechanical ventilation in cancer patients is a critical issue The present prospective descriptive study was designed (1) to assess the patient population needing respirator support in ward setting at a premier state-run oncology institute in India, (2) to observe and analyze the course of their disease while on respirator, and (3) to coordinate better quality of life measures in cancer patients at the institute based on the present study's outcomes. Beginning from March 2005 to March 2006, all cancer patients who were connected to respirator in the wards were enrolled in the current study. Our anesthesiology department at the cancer institute also has primary responsibility for airway management and mechanical ventilation in high dependency units of oncology wards. Preventilation variables in cancer patients were assessed to judge the futility of mechanical ventilation in ward setting. Subsequently, patients were observed for disease course while on respirator. Final outcome with its etio-pathogenesis was correlated with predicted futility of mechanical ventilation. Over a period of 1 year, 132 (46 men and 86 women) cancer patients with median age 40 years (range 1-75 years) were connected to respirator in oncology wards. Based on the preventilation variables and indications for respirator support, right prediction of medical futility and hospital discharge was made in 77% of patients. Underestimation and overestimation of survival to hospital discharge was made in 10% cases and 13% cases, respectively. Based on preventilation variables, prediction of outcome in cancer patients needing respirator support can be made in 77% cases. This high probability of prediction can be used to educate patients, and their families and primary physicians, for well-informed and documented advance directives, formulated and regularly revised DNAR policies, and judicious use of respirator support for better quality-of-life outcomes.
Anand, Kanwaljeet J S; Clark, Amy E; Willson, Douglas F; Berger, John; Meert, Kathleen L; Zimmerman, Jerry J; Harrison, Rick; Carcillo, Joseph A; Newth, Christopher J L; Bisping, Stephanie; Holubkov, Richard; Dean, J Michael; Nicholson, Carol E
2013-01-01
To examine the clinical factors associated with increased opioid dose among mechanically ventilated children in the pediatric intensive care unit. Prospective, observational study with 100% accrual of eligible patients. Seven pediatric intensive care units from tertiary-care children's hospitals in the Collaborative Pediatric Critical Care Research Network. Four hundred nineteen children treated with morphine or fentanyl infusions. None. Data on opioid use, concomitant therapy, demographic and explanatory variables were collected. Significant variability occurred in clinical practices, with up to 100-fold differences in baseline opioid doses, average daily or total doses, or peak infusion rates. Opioid exposure for 7 or 14 days required doubling of the daily opioid dose in 16% patients (95% confidence interval 12%-19%) and 20% patients (95% confidence interval 16%-24%), respectively. Among patients receiving opioids for longer than 3 days (n = 225), this occurred in 28% (95% confidence interval 22%-33%) and 35% (95% confidence interval 29%-41%) by 7 or 14 days, respectively. Doubling of the opioid dose was more likely to occur following opioid infusions for 7 days or longer (odds ratio 7.9, 95% confidence interval 4.3-14.3; p < 0.001) or co-therapy with midazolam (odds ratio 5.6, 95% confidence interval 2.4-12.9; p < 0.001), and it was less likely to occur if morphine was used as the primary opioid (vs. fentanyl) (odds ratio 0.48, 95% confidence interval 0.25-0.92; p = 0.03), for patients receiving higher initial doses (odds ratio 0.96, 95% confidence interval 0.95-0.98; p < 0.001), or if patients had prior pediatric intensive care unit admissions (odds ratio 0.37, 95% confidence interval 0.15-0.89; p = 0.03). Mechanically ventilated children require increasing opioid doses, often associated with prolonged opioid exposure or the need for additional sedation. Efforts to reduce prolonged opioid exposure and clinical practice variation may prevent the complications of opioid therapy.
An experimental study of an adaptive-wall wind tunnel
NASA Technical Reports Server (NTRS)
Celik, Zeki; Roberts, Leonard
1988-01-01
A series of adaptive wall ventilated wind tunnel experiments was carried out to demonstrate the feasibility of using the side wall pressure distribution as the flow variable for the assessment of compatibility with free air conditions. Iterative and one step convergence methods were applied using the streamwise velocity component, the side wall pressure distribution and the normal velocity component in order to investigate their relative merits. The advantage of using the side wall pressure as the flow variable is to reduce the data taking time which is one the major contributors to the total testing time. In ventilated adaptive wall wind tunnel testing, side wall pressure measurements require simple instrumentation as opposed to the Laser Doppler Velocimetry used to measure the velocity components. In ventilated adaptive wall tunnel testing, influence coefficients are required to determine the pressure corrections in the plenum compartment. Experiments were carried out to evaluate the influence coefficients from side wall pressure distributions, and from streamwise and normal velocity distributions at two control levels. Velocity measurements were made using a two component Laser Doppler Velocimeter system.
Rigo, Vincent; Graas, Estelle; Rigo, Jacques
2012-07-01
Selected optimal respiratory cycles should allow calculation of respiratory mechanic parameters focusing on patient-ventilator interaction. New computer software automatically selecting optimal breaths and respiratory mechanics derived from those cycles are evaluated. Retrospective study. University level III neonatal intensive care unit. Ten mins synchronized intermittent mandatory ventilation and assist/control ventilation recordings from ten newborns. The ventilator provided respiratory mechanic data (ventilator respiratory cycles) every 10 secs. Pressure, flow, and volume waves and pressure-volume, pressure-flow, and volume-flow loops were reconstructed from continuous pressure-volume recordings. Visual assessment determined assisted leak-free optimal respiratory cycles (selected respiratory cycles). New software graded the quality of cycles (automated respiratory cycles). Respiratory mechanic values were derived from both sets of optimal cycles. We evaluated quality selection and compared mean values and their variability according to ventilatory mode and respiratory mechanic provenance. To assess discriminating power, all 45 "t" values obtained from interpatient comparisons were compared for each respiratory mechanic parameter. A total of 11,724 breaths are evaluated. Automated respiratory cycle/selected respiratory cycle selections agreement is high: 88% of maximal κ with linear weighting. Specificity and positive predictive values are 0.98 and 0.96, respectively. Averaged values are similar between automated respiratory cycle and ventilator respiratory cycle. C20/C alone is markedly decreased in automated respiratory cycle (1.27 ± 0.37 vs. 1.81 ± 0.67). Tidal volume apparent similarity disappears in assist/control: automated respiratory cycle tidal volume (4.8 ± 1.0 mL/kg) is significantly lower than for ventilator respiratory cycle (5.6 ± 1.8 mL/kg). Coefficients of variation decrease for all automated respiratory cycle parameters in all infants. "t" values from ventilator respiratory cycle data are two to three times higher than ventilator respiratory cycles. Automated selection is highly specific. Automated respiratory cycle reflects most the interaction of both ventilator and patient. Improving discriminating power of ventilator monitoring will likely help in assessing disease status and following trends. Averaged parameters derived from automated respiratory cycles are more precise and could be displayed by ventilators to improve real-time fine tuning of ventilator settings.
NASA Astrophysics Data System (ADS)
Kumar, Manish; Sharma, Navjeet; Sarin, Amit
2018-05-01
Studies have confirmed that elevated levels of radon/thoron in the human-environments can substantially increase the risk of lung cancer in general population. The building materials are the second largest contributors to indoor radon/thoron after soil and bedrock beneath dwellings. In present investigation, the exhalation rates of radon/thoron from different building materials samples have been analysed using active technique. Radon/thoron concentrations in a model room have been predicted based on the exhalation rates from walls, floor and roof. The indoor concentrations show significant variations depending upon the ventilation rate and type of building materials used.
Morgan, Stephen; Hornik, Christoph P; Patel, Niyati; Williford, Walter L; Turner, David A; Cheifetz, Ira M
2016-11-01
Continuous high-frequency oscillation (CHFO) creates a pressure gradient in the small airways that accelerates expiratory flow. The intended use of CHFO therapy is to facilitate secretion removal and treat atelectasis. Our objective was to assess the feasibility, safety, and efficacy of CHFO in the mechanically ventilated pediatric population. After institutional review board approval, we retrospectively reviewed medical records of mechanically ventilated children treated with CHFO (the MetaNeb system) at our institution from July 1, 2007 through August 31, 2012. Patients supported with extracorporeal membrane oxygenation were excluded. We evaluated changes in ventilator settings in subjects with ventilator data documented within 6 h pre- and post-treatment. We evaluated arterial blood gas (ABG) results for individual treatments, comparing ABG results within 8 h pre-therapy to ABG results within 3 h post-treatment. Oxygen index and P aO 2 /F IO 2 were calculated. Demographic data, blood pressure, heart rate, and development of new air leak while being treated with CHFO were recorded. Pre- and post-CHFO measurements were compared using Wilcoxon signed-rank testing. Our cohort included 59 invasively ventilated subjects. Median age was 2 y (range 1 month to 19 y), and median weight was 14 kg (2-81 kg). We evaluated data on 528 total treatments (range per subject 1-39 treatments). Peak inspiratory pressure significantly decreased with CHFO, whereas other parameters, including P aCO 2 and breathing frequency, remained stable. There was no significant change in systolic blood pressure, diastolic blood pressure, or heart rate following treatment with CHFO. One subject (2%) developed a clinically insignificant pneumothorax during CHFO. CHFO is feasible and seems safe in our cohort of mechanically ventilated pediatric subjects. The rate of pneumothorax was consistent with that seen in similar pediatric ICU populations. These preliminary results suggest that CHFO may be beneficial by improving lung compliance in pediatric subjects with secretion-induced atelectasis. Prospective clinical studies are needed to further evaluate the clinical efficacy and safety of CHFO in children receiving invasive mechanical ventilation. Copyright © 2016 by Daedalus Enterprises.
[Prolonged mechanical ventilation probability model].
Añón, J M; Gómez-Tello, V; González-Higueras, E; Oñoro, J J; Córcoles, V; Quintana, M; López-Martínez, J; Marina, L; Choperena, G; García-Fernández, A M; Martín-Delgado, C; Gordo, F; Díaz-Alersi, R; Montejo, J C; Lorenzo, A García de; Pérez-Arriaga, M; Madero, R
2012-10-01
To design a probability model for prolonged mechanical ventilation (PMV) using variables obtained during the first 24 hours of the start of MV. An observational, prospective, multicenter cohort study. Thirteen Spanish medical-surgical intensive care units. Adult patients requiring mechanical ventilation for more than 24 hours. None. APACHE II, SOFA, demographic data, clinical data, reason for mechanical ventilation, comorbidity, and functional condition. A multivariate risk model was constructed. The model contemplated a dependent variable with three possible conditions: 1. Early mortality; 2. Early extubation; and 3. PMV. Of the 1661 included patients, 67.9% (n=1127) were men. Age: 62.1±16.2 years. APACHE II: 20.3±7.5. Total SOFA: 8.4±3.5. The APACHE II and SOFA scores were higher in patients ventilated for 7 or more days (p=0.04 and p=0.0001, respectively). Noninvasive ventilation failure was related to PMV (p=0.005). A multivariate model for the three above exposed outcomes was generated. The overall accuracy of the model in the training and validation sample was 0.763 (95%IC: 0.729-0.804) and 0.751 (95%IC: 0.672-0.816), respectively. The likelihood ratios (LRs) for early extubation, involving a cutoff point of 0.65, in the training sample were LR (+): 2.37 (95%CI: 1.77-3.19) and LR (-): 0.47 (95%CI: 0.41-0.55). The LRs for the early mortality model, for a cutoff point of 0.73, in the training sample, were LR (+): 2.64 (95%CI: 2.01-3.4) and LR (-): 0.39 (95%CI: 0.30-0.51). The proposed model could be a helpful tool in decision making. However, because of its moderate accuracy, it should be considered as a first approach, and the results should be corroborated by further studies involving larger samples and the use of standardized criteria. Copyright © 2011 Elsevier España, S.L. y SEMICYUC. All rights reserved.
Mehta, Jaideep H; Cattano, Davide; Brayanov, Jordan B; George, Edward E
2017-04-26
Monitoring the adequacy of spontaneous breathing is a major patient safety concern in the post-operative setting. Monitoring is particularly important for obese patients, who are at a higher risk for post-surgical respiratory complications and often have increased metabolic demand due to excess weight. Here we used a novel, noninvasive Respiratory Volume Monitor (RVM) to monitor ventilation in both obese and non-obese orthopedic patients throughout their perioperative course, in order to develop better monitoring strategies. We collected respiratory data from 62 orthopedic patients undergoing elective joint replacement surgery under general anesthesia using a bio-impedance based RVM with an electrode PadSet placed on the thorax. Patients were stratified into obese (BMI ≥ 30) and non-obese cohorts and minute ventilation (MV) at various perioperative time points was compared against each patient's predicted minute ventilation (MV PRED ) based on ideal body weight (IBW) and body surface area (BSA). The distributions of MV measurements were also compared across obese and non-obese cohorts. Obese patients had higher MV than the non-obese patients before, during, and after surgery. Measured MV of obese patients was significantly higher than their MV PRED from IBW formulas, with BSA-based MV PRED being a closer estimate. Obese patients also had greater variability in MV post-operatively when treated with standard opioid dosing. Our study demonstrated that obese patients have greater variability in ventilation post-operatively when treated with standard opioid doses, and despite overall higher ventilation, many of them are still at risk for hypoventilation. BSA-based MV PRED formulas may be more appropriate than IBW-based ones when estimating the respiratory demand of obese patients. The RVM allows for the continuous and non-invasive assessment of respiratory function in both obese and non-obese patients.
Elgebaly, Ahmed Said
2017-01-01
Background: Respiratory failure is of concern in the postoperative period after cardiac surgeries. Invasive ventilation (intermittent positive pressure ventilation [IPPV]) carries the risks and complications of intubation and mechanical ventilation (MV). Aims: Noninvasive positive pressure ventilation (NIPPV) is an alternative method and as effective as IPPV in treating insufficiency of respiration with less complications and minimal effects on respiratory and hemodynamic parameters next to open-heart surgery. Design: This is a prospective, randomized and controlled study. Materials and Methods: Forty-four patients scheduled for cardiac surgery were divided into two equal groups: Group I (IPPV) and Group II (NIPPV). Heart rate (HR), mean arterial pressure (MAP), respiratory rate (RR), oxygen saturation (SpO2), arterial blood gas, weaning time, reintubation, tracheotomy rate, MV time, postoperative hospital stay, and ventilator-associated pneumonia during the period of hospital stay were recorded. Results: There was statistically significant difference in HR between groups with higher in Group I at 30 and 60 min and at 12 and 24 h. According to MAP, it started to increase significantly at hypoxemia, 15 min, 30 min, 4 h, 12 h, and at 24 h which was higher in Group I also. RR, PaO2, and PaCO2 showed significant higher in Group II at 15, 30, and 60 min and 4 h. According to pH, there was a significant difference between groups at 15, 30, and 60 min and at 4, 12, and 24 h postoperatively. SpO2 showed higher significant values in Group I at 15 and 30 min and at 12 h postoperatively. Duration of postoperative supportive ventilation was higher in Group I than that of Group II with statistically significant difference. Complications were statistically insignificant between Group I and Group II. Conclusion: Our study showed superiority of invasive over noninvasive mode of ventilator support. However, NIPPV (bilevel positive airway pressure) was proved to be a safe method. PMID:28994676
NASA Astrophysics Data System (ADS)
Battista, L.; Scorza, A.; Botta, F.; Sciuto, S. A.
2016-02-01
Published standards for the performance evaluation of pulmonary ventilators are mainly directed to manufacturers rather than to end-users and often considered inadequate or not comprehensive. In order to contribute to overcome the problems above, a novel measurement system was proposed and tested with waveforms of mechanical ventilation by means of experimental trials carried out with infant ventilators typically used in neonatal intensive care units: the main quantities of mechanical ventilation in newborns are monitored, i.e. air flow rate, differential pressure and volume from infant ventilator are measured by means of two novel fiber-optic sensors (OFSs) developed and characterized by the authors, while temperature and relative humidity of air mass are obtained by two commercial transducers. The proposed fiber-optic sensors (flow sensor Q-OFS, pressure sensor P-OFS) showed measurement ranges of air flow and pressure typically encountered in neonatal mechanical ventilation, i.e. the air flow rate Q ranged from 3 l min-1 to 18 l min-1 (inspiratory) and from -3 l min-1 to -18 l min-1 (expiratory), the differential pressure ΔP ranged from -15 cmH2O to 15 cmH2O. In each experimental trial carried out with different settings of the ventilator, outputs of the OFSs are compared with data from two reference sensors (reference flow sensor RF, reference pressure sensor RP) and results are found consistent: flow rate Q showed a maximum error between Q-OFS and RF up to 13 percent, with an output ratio Q RF/Q OFS of not more than 1.06 ± 0.09 (least square estimation, 95 percent confidence level, R 2 between 0.9822 and 0.9931). On the other hand the maximum error between P-OFS and RP on differential pressure ΔP was lower than 10 percent, with an output ratio ΔP RP/ΔP OFS between 0.977 ± 0.022 and 1.0 ± 0.8 (least square estimation, 95 percent confidence level, R 2 between 0.9864 and 0.9876). Despite the possible improvements, results were encouraging and suggested the proposed measurement system can be considered suitable for performances evaluation of neonatal ventilators and useful for both end-users and manufacturers.
Frankenfield, David C; Ashcraft, Christine M; Drasher, Tammy L; Reid, Elizabeth K; Vender, Robert L
2017-05-01
Critically ill patients with cystic fibrosis may be especially sensitive to the negative consequences of overfeeding and underfeeding, yet there is almost no information available about the energy needs of these patients. The purpose of this study was to characterize the metabolic rate of critically ill adult patients with cystic fibrosis requiring mechanical ventilation. This was an observational study in which the resting metabolic rate, oxygen consumption, and carbon dioxide production of adult patients with cystic fibrosis requiring critical care, sedation, and mechanical ventilation were measured with indirect calorimetry. This group was compared with a cohort of adult critical care patients without cystic fibrosis. Twelve patients with cystic fibrosis were identified and measured. These were compared with a control group of 25 critically ill patients. Both groups were underweight (body mass index, 17.4 ± 4.0 kg/m 2 in cystic fibrosis and 18.4 ± 2.3 kg/m 2 in control). Adjusting for differences in age, sex, height, and weight, there was no difference in resting metabolic rate between the cystic fibrosis and control groups (1702 ± 193 vs 1642 ± 194 kcal/d, P = .388). Measured resting metabolic rate matched predicted values 58% of the time in cystic fibrosis and 60% of the time in control. The resting metabolic rate of sedated adult patients with cystic fibrosis being assisted with mechanical ventilation is not different from that of adult critical care patients without cystic fibrosis. In both these underweight groups, accurate prediction of resting metabolic rate is difficult to obtain.
Barton, Samantha K; Moss, Timothy J M; Hooper, Stuart B; Crossley, Kelly J; Gill, Andrew W; Kluckow, Martin; Zahra, Valerie; Wong, Flora Y; Pichler, Gerhard; Galinsky, Robert; Miller, Suzanne L; Tolcos, Mary; Polglase, Graeme R
2014-01-01
The onset of mechanical ventilation is a critical time for the initiation of cerebral white matter (WM) injury in preterm neonates, particularly if they are inadvertently exposed to high tidal volumes (VT) in the delivery room. Protective ventilation strategies at birth reduce ventilation-induced lung and brain inflammation and injury, however its efficacy in a compromised newborn is not known. Chorioamnionitis is a common antecedent of preterm birth, and increases the risk and severity of WM injury. We investigated the effects of high VT ventilation, after chorioamnionitis, on preterm lung and WM inflammation and injury, and whether a protective ventilation strategy could mitigate the response. Pregnant ewes (n = 18) received intra-amniotic lipopolysaccharide (LPS) 2 days before delivery, instrumentation and ventilation at 127±1 days gestation. Lambs were either immediately euthanased and used as unventilated controls (LPSUVC; n = 6), or were ventilated using an injurious high VT strategy (LPSINJ; n = 5) or a protective ventilation strategy (LPSPROT; n = 7) for a total of 90 min. Mean arterial pressure, heart rate and cerebral haemodynamics and oxygenation were measured continuously. Lungs and brains underwent molecular and histological assessment of inflammation and injury. LPSINJ lambs had poorer oxygenation than LPSPROT lambs. Ventilation requirements and cardiopulmonary and systemic haemodynamics were not different between ventilation strategies. Compared to unventilated lambs, LPSINJ and LPSPROT lambs had increases in pro-inflammatory cytokine expression within the lungs and brain, and increased astrogliosis (p<0.02) and cell death (p<0.05) in the WM, which were equivalent in magnitude between groups. Ventilation after acute chorioamnionitis, irrespective of strategy used, increases haemodynamic instability and lung and cerebral inflammation and injury. Mechanical ventilation is a potential contributor to WM injury in infants exposed to chorioamnionitis.
Maslow, Andrew D; Stafford, Todd S; Davignon, Kristopher R; Ng, Thomas
2013-07-01
Protective lung ventilation is reported to benefit patients with acute respiratory distress syndrome. It is not known whether protective lung ventilation is also beneficial to patients undergoing single-lung ventilation for elective pulmonary resection. In an institutional review board-approved prospective randomized trial, 34 patients undergoing elective pulmonary resection requiring single-lung ventilation were enrolled. Informed consent was obtained. Patients were randomized to 1 of 2 groups: (1) high tidal volume (Hi-TV) of 10 mL/kg, rate of 7 breaths/min, and zero positive end-expiratory pressure or (2) low tidal volume (Lo-TV) of 5 mL/kg, rate of 14 breaths/min, and 5 cmH2O positive end-expiratory pressure. Ventilator settings were continued during both double- and single-lung ventilation. Pulmonary functions, hemodynamics, and postoperative outcomes were recorded. Patient demographics, operative characteristics, intraoperative hemodynamics, and postoperative pain and sedation scores were similar between the 2 groups. During most time periods, airway pressures (peak and plateau) were significantly higher in the Hi-TV group; however, plateau pressures remained less than 30 cmH2O at all times for all patients. The Hi-TV group had significantly lower arterial carbon dioxide tension, less arterial carbon dioxide tension-end-tidal carbon dioxide gradient, lower alveolar dead space ratio, and higher dynamic pulmonary compliance. There were no differences in postoperative morbidity and hospital days between the 2 groups, but atelectasis scores on postoperative days 1 and 2 were lower in the Hi-TV group. The use of Hi-TV during single-lung ventilation for pulmonary resection resulted in no increase in morbidity and was associated with less hypercarbia, less dead space ventilation, better dynamic compliance, and less postoperative atelectasis. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Marjanovic, Nicolas; Le Floch, Soizig; Jaffrelot, Morgan; L'Her, Erwan
2014-05-01
In the absence of endotracheal intubation, the manual bag-valve-mask (BVM) is the most frequently used ventilation technique during resuscitation. The efficiency of other devices has been poorly studied. The bench-test study described here was designed to evaluate the effectiveness of an automatic, manually triggered system, and to compare it with manual BVM ventilation. A respiratory system bench model was assembled using a lung simulator connected to a manikin to simulate a patient with unprotected airways. Fifty health-care providers from different professional groups (emergency physicians, residents, advanced paramedics, nurses, and paramedics; n = 10 per group) evaluated manual BVM ventilation, and compared it with an automatic manually triggered device (EasyCPR). Three pathological situations were simulated (restrictive, obstructive, normal). Standard ventilation parameters were recorded; the ergonomics of the system were assessed by the health-care professionals using a standard numerical scale once the recordings were completed. The tidal volume fell within the standard range (400-600 mL) for 25.6% of breaths (0.6-45 breaths) using manual BVM ventilation, and for 28.6% of breaths (0.3-80 breaths) using the automatic manually triggered device (EasyCPR) (P < .0002). Peak inspiratory airway pressure was lower using the automatic manually triggered device (EasyCPR) (10.6 ± 5 vs 15.9 ± 10 cm H2O, P < .001). The ventilation rate fell consistently within the guidelines, in the case of the automatic manually triggered device (EasyCPR) only (10.3 ± 2 vs 17.6 ± 6, P < .001). Significant pulmonary overdistention was observed when using the manual BVM device during the normal and obstructive sequences. The nurses and paramedics considered the ergonomics of the automatic manually triggered device (EasyCPR) to be better than those of the manual device. The use of an automatic manually triggered device may improve ventilation efficiency and decrease the risk of pulmonary overdistention, while decreasing the ventilation rate.
NASA Astrophysics Data System (ADS)
Yang, Dan-dan; Yu, An; Ji, Bin; Zhou, Jia-jian; Luo, Xian-wu
2018-04-01
The present paper studies the ventilated cavitation over a NACA0015 hydrofoil by numerical methods. The corresponding cavity evolutions are obtained at three ventilation rates by using the level set method. To depict the complicated turbulent flow structure, the filter-based density corrected model (FBDCM) and the modified partially-averaged Navier-Stokes (MPANS) model are applied in the present numerical analyses. It is indicated that the predicted results of the cavitation shedding dynamics by both turbulence models agree fairly well with the experimental data. It is also noted that the shedding frequency and the super cavity length predicted by the MPANS method are closer to the experiment data as compared to that predicted by the FBDCM model. The simulation results show that in the ventilated cavitation, the vapor cavity and the air cavity have the same shedding frequency. As the ventilated rate increases, the vapor cavity is depressed rapidly. The cavitation-vortex interaction in the ventilated cavitation is studied based on the vorticity transport equation (VTE) and the Lagrangian coherent structure (LCS). Those results demonstrate that the vortex dilatation and baroclinic torque terms are highly dependent on the evolution of the cavitation. In addition, from the LCSs and the tracer particles in the flow field, one may see the process from the attached cavity to the cloud cavity.
Nonrapid Eye Movement-Predominant Obstructive Sleep Apnea: Detection and Mechanism.
Yamauchi, Motoo; Fujita, Yukio; Kumamoto, Makiko; Yoshikawa, Masanori; Ohnishi, Yoshinobu; Nakano, Hiroshi; Strohl, Kingman P; Kimura, Hiroshi
2015-09-15
Obstructive sleep apnea (OSA) can be severe and present in higher numbers during rapid eye movement (REM) than nonrapid eye movement (NREM) sleep; however, OSA occurs in NREM sleep and can be predominant. In general, ventilation decreases an average 10% to 15% during transition from wakefulness to sleep, and there is variability in just how much ventilation decreases. As dynamic changes in ventilation contribute to irregular breathing and breathing during NREM sleep is mainly under chemical control, our hypothesis is that patients with a more pronounced reduction in ventilation during the transition from wakefulness to NREM sleep will have NREM- predominant rather than REM-predominant OSA. A retrospective analysis of 451 consecutive patients (apnea-hypopnea index [AHI] > 5) undergoing diagnostic polysomnography was performed, and breath-to-breath analysis of the respiratory cycle duration, tidal volume, and estimated minute ventilation before and after sleep onset were examined. Values were calculated using respiratory inductance plethysmography. The correlation between the percent change in estimated minute ventilation during wake-sleep transitions and the percentage of apnea-hypopneas in NREM sleep (%AHI in NREM; defined as (AHI-NREM) / [(AHI-NREM) + (AHI-REM)] × 100) was the primary outcome. The decrease in estimated minute ventilation during wake-sleep transitions was 15.0 ± 16.6% (mean ± standard deviation), due to a decrease in relative tidal volume. This decrease in estimated minute ventilation was significantly correlated with %AHI in NREM (r = -0.222, p < 0.01). A greater dynamic reduction in ventilation back and forth from wakefulness to sleep contributes to the NREM predominant OSA phenotype via induced ventilatory instability. © 2015 American Academy of Sleep Medicine.
Asthma prevalence in German Olympic athletes: A comparison of winter and summer sport disciplines.
Selge, Charlotte; Thomas, Silke; Nowak, Dennis; Radon, Katja; Wolfarth, Bernd
2016-09-01
Prevalence of asthma in elite athletes shows very wide ranges. It remains unclear to what extent this is influenced by the competition season (winter vs. summer) or the ventilation rate achieved during competition. The aim of this study was to evaluate prevalence of asthma in German elite winter and summer athletes from a wide range of sport disciplines and to identify high risk groups. In total, 265 German elite winter athletes (response 77%) and 283 German elite summer athletes (response 64%) answered validated respiratory questionnaires. Using logistic regression, the asthma risks associated with competition season and ventilation rate during competition, respectively, were investigated. A subset of winter athletes was also examined for their FENO-levels and lung function. With respect to all asthma outcomes, no association was found with the competition season. Regarding the ventilation rate, athletes in high ventilation sports were at increased risk of asthma, as compared to athletes in low ventilation sports (doctors' diagnosed asthma: OR 2.32, 95% CI 1.19-4.53; use of asthma medication: OR 4.46, 95% CI 1.52-13.10; current wheeze or use of asthma medication: OR 2.78, 95% CI 1.34-5.76). Athletes with doctors' diagnosed asthma were at an approximate four-fold risk of elevated FENO-values. The clinically relevant finding of this study is that athletes' asthma seems to be more common in sports with high ventilation during competition, whereas the summer or winter season had no impact on the frequency of the disease. Among winter athletes, elevated FENO suggested suboptimal control of asthma. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Tianzhen; Fisk, William J.
2009-07-08
Demand controlled ventilation (DCV) was evaluated for general office spaces in California. A medium size office building meeting the prescriptive requirements of the 2008 California building energy efficiency standards (CEC 2008) was assumed in the building energy simulations performed with the EnergyPlus program to calculate the DCV energy savings potential in five typical California climates. Three design occupancy densities and two minimum ventilation rates were used as model inputs to cover a broader range of design variations. The assumed values of minimum ventilation rates in offices without DCV, based on two different measurement methods, were 81 and 28 cfm per occupant. These rates are based on the co-author's unpublished analyses of data from EPA's survey of 100 U.S. office buildings. These minimum ventilation rates exceed the 15 to 20 cfm per person required in most ventilation standards for offices. The cost effectiveness of applying DCV in general office spaces was estimated via a life cycle cost analyses that considered system costs and energy cost reductions. The results of the energy modeling indicate that the energy savings potential of DCV is largest in the desert area of California (climate zone 14), followed by Mountains (climate zone 16), Central Valley (climate zone 12), North Coast (climate zone 3), and South Coast (climate zone 6). The results of the life cycle cost analysis show DCV is cost effective for office spaces if the typical minimum ventilation rates without DCV is 81 cfm per person, except at the low design occupancy of 10 people per 1000 ft{sup 2} in climate zones 3 and 6. At the low design occupancy of 10 people per 1000 ft{sup 2}, the greatest DCV life cycle cost savings is a net present value (NPV) ofmore » $$0.52/ft{sup 2} in climate zone 14, followed by $$0.32/ft{sup 2} in climate zone 16 and $$0.19/ft{sup 2} in climate zone 12. At the medium design occupancy of 15 people per 1000 ft{sup 2}, the DCV savings are higher with a NPV $$0.93/ft{sup 2} in climate zone 14, followed by $$0.55/ft{sup 2} in climate zone 16, $$0.46/ft{sup 2} in climate zone 12, $$0.30/ft{sup 2} in climate zone 3, $$0.16/ft{sup 2} in climate zone 3. At the high design occupancy of 20 people per 1000 ft{sup 2}, the DCV savings are even higher with a NPV $$1.37/ft{sup 2} in climate zone 14, followed by $$0.86/ft{sup 2} in climate zone 16, $$0.84/ft{sup 2} in climate zone 3, $$0.82/ft{sup 2} in climate zone 12, and $0.65/ft{sup 2} in climate zone 6. DCV was not found to be cost effective if the typical minimum ventilation rate without DCV is 28 cfm per occupant, except at high design occupancy of 20 people per 1000 ft{sup 2} in climate zones 14 and 16. Until the large uncertainties about the base case ventilation rates in offices without DCV are reduced, the case for requiring DCV in general office spaces will be a weak case.« less
Modrykamien, Ariel M; Daoud, Yahya
2018-01-01
Optimal mechanical ventilation management in patients with the acute respiratory distress syndrome (ARDS) involves the use of low tidal volumes and limited plateau pressure. Refractory hypoxemia may not respond to this strategy, requiring other interventions. The use of prone positioning in severe ARDS resulted in improvement in 28-day survival. To determine whether mechanical ventilation strategies or other parameters affected survival in patients undergoing prone positioning, a retrospective analysis was conducted of a consecutive series of patients with severe ARDS treated with prone positioning. Demographic and clinical information involving mechanical ventilation strategies, as well as other variables associated with prone positioning, was collected. The rate of in-hospital mortality was obtained, and previously described parameters were compared between survivors and nonsurvivors. Forty-three patients with severe ARDS were treated with prone positioning, and 27 (63%) died in the intensive care unit. Only three parameters were significant predictors of survival: APACHE II score ( P = 0.03), plateau pressure ( P = 0.02), and driving pressure ( P = 0.04). The ability of each of these parameters to predict mortality was assessed with receiver operating characteristic curves. The area under the curve values for APACHE II, plateau pressure, and driving pressure were 0.74, 0.69, and 0.67, respectively. In conclusion, in a group of patients with severe ARDS treated with prone positioning, only APACHE II, plateau pressure, and driving pressure were associated with mortality in the intensive care unit.
Modeling the Progression of Epithelial Leak Caused by Overdistension
Hamlington, Katharine L.; Ma, Baoshun; Smith, Bradford J.; Bates, Jason H. T.
2016-01-01
Mechanical ventilation is necessary for treatment of the acute respiratory distress syndrome but leads to overdistension of the open regions of the lung and produces further damage. Although we know that the excessive stresses and strains disrupt the alveolar epithelium, we know little about the relationship between epithelial strain and epithelial leak. We have developed a computational model of an epithelial monolayer to simulate leak progression due to overdistension and to explain previous experimental findings in mice with ventilator-induced lung injury. We found a nonlinear threshold-type relationship between leak area and increasing stretch force. After the force required to initiate the leak was reached, the leak area increased at a constant rate with further increases in force. Furthermore, this rate was slower than the rate of increase in force, especially at end-expiration. Parameter manipulation changed only the leak-initiating force; leak area growth followed the same trend once this force was surpassed. These results suggest that there is a particular force (analogous to ventilation tidal volume) that must not be exceeded to avoid damage and that changing cell physical properties adjusts this threshold. This is relevant for the development of new ventilator strategies that avoid inducing further injury to the lung. PMID:26951764
Pandemic influenza-implications for critical care resources in Australia and New Zealand.
Anderson, Therese A; Hart, Graeme K; Kainer, Marion A
2003-09-01
To quantify resource requirements (additional beds and ventilator capacity), for critical care services in the event of pandemic influenza. Cross-sectional survey about existing and potential critical care resources. Participants comprised 156 of the 176 Australasian (Australia and New Zealand) critical care units on the database of the Australian and New Zealand Intensive Care Society (ANZICS) Research Centre for Critical Care Resources. The Meltzer, Cox and Fukuda model was adapted to map a range of influenza attack rate estimates for hospitalisation and episodes likely to require intensive care and to predict critical care admission rates and bed day requirements. Estimations of ventilation rates were based on those for community-acquired pneumonia. The estimated extra number of persons requiring hospitalisation ranged from 8,455 (10% attack rate) to 150,087 (45% attack rate). The estimated number of additional admissions to critical care units ranged from 423 (5% admission rate, 10% attack rate) to 37,522 (25% admission rate, 45% attack rate). The potential number of required intensive care bed days ranged from 846 bed days (2 day length of stay, 10% attack rate) to 375,220 bed days (10 day length of stay, 45% attack rate). The number of persons likely to require mechanical ventilation ranged from 106 (25% of projected critical care admissions, 10% attack rate) to 28,142 (75% of projected critical care admissions, 45% attack rate). An additional 1,195 emergency ventilator beds were identified in public sector and 248 in private sector hospitals. Cancellation of elective surgery could release a potential 76,402 intensive care bed days (per annum), but in the event of pandemic influenza, 31,150 bed days could be required over an 8- to 12-week period. Australasian critical care services would be overwhelmed in the event of pandemic influenza. More work is required in relation to modelling, contingency plans, and resource allocation.
Bebarta, Vikhyat S; Garrett, Normalynn; Brenner, Matthew; Mahon, Sari B; Maddry, Joseph K; Boudreau, Susan; Castaneda, Maria; Boss, Gerry R
2017-09-01
Hydrogen sulfide (H 2 S) is a potentially deadly gas that naturally occurs in petroleum and natural gas. The Occupational Health and Safety Administration cites H 2 S as a leading cause of workplace gas inhalation deaths. Mass casualties of H 2 S toxicity may be caused by exposure from industrial accidents or release from oil field sites. H 2 S is also an attractive terrorism tool because of its high toxicity and ease with which it can be produced. Several potential antidotes have been proposed for hydrogen sulfide poisoning but none have been completely successful. The objective was to compare treatment response assessed by the time to spontaneous ventilation among groups of swine with acute H 2 S-induced apnea treated with intravenous (IV) cobinamide (4 mg/kg in 0.8 mL of 225 mmol/L solution), IV hydroxocobalamin (4 mg/kg in 5 mL of saline), or saline alone. Twenty-four swine (45-55 kg) were anesthetized, intubated, and instrumented with continuous femoral and pulmonary artery pressure monitoring. After stabilization, anesthesia was adjusted such that animals would spontaneously ventilate with an FiO 2 of 0.21. Sodium hydrosulfide (NaHS; concentration of 8 mg/mL) was begun at 1 mg/kg/min until apnea was confirmed for 20 seconds by capnography. This infusion rate was sustained for 1.5 minutes postapnea and then decreased to a maintenance rate for the remainder of the study to replicate sustained clinical exposure. Animals were randomly assigned to receive cobinamide (4 mg/kg), hydroxocobalamin (4 mg/kg), or saline and monitored for 60 minutes beginning 1 minute postapnea. G* power analysis using the Z-test determined that equal group sizes of eight animals were needed to achieve a power of 80% in detecting a 50% difference in return to spontaneous ventilations at α = 0.05. There were no significant differences in baseline variables. Moreover, there were no significant differences in the mg/kg dose of NaHS (5.6 mg/kg; p = 0.45) required to produce apnea. Whereas all of the cobinamide-treated animals survived (8/8), none of the control (0/8) or hydroxocobalamin (0/8)-treated animals survived. Mean (±SD) time to spontaneous ventilation in the cobinamide-treated animals was 3.2 (±1.1) minutes. Cobinamide successfully rescued the severely NaHS-poisoned swine from apnea in the absence of assisted ventilation. © 2017 by the Society for Academic Emergency Medicine.
Dostál, P; Senkeřík, M; Pařízková, R; Bareš, D; Zivný, P; Zivná, H; Cerný, V
2010-01-01
Hypothermia was shown to attenuate ventilator-induced lung injury due to large tidal volumes. It is unclear if the protective effect of hypothermia is maintained under less injurious mechanical ventilation in animals without previous lung injury. Tracheostomized rats were randomly allocated to non-ventilated group (group C) or ventilated groups of normothermia (group N) and mild hypothermia (group H). After two hours of mechanical ventilation with inspiratory fraction of oxygen 1.0, respiratory rate 60 min(-1), tidal volume 10 ml x kg(-1), positive end-expiratory pressure (PEEP) 2 cm H2O or immediately after tracheostomy in non-ventilated animals inspiratory pressures were recorded, rats were sacrificed, pressure-volume (PV) curve of respiratory system constructed, bronchoalveolar lavage (BAL) fluid and aortic blood samples obtained. Group N animals exhibited a higher rise in peak inspiratory pressures in comparison to group H animals. Shift of the PV curve to right, higher total protein and interleukin-6 levels in BAL fluid were observed in normothermia animals in comparison with hypothermia animals and non-ventilated controls. Tumor necrosis factor-alpha was lower in the hypothermia group in comparison with normothermia and non-ventilated groups. Mild hypothermia attenuated changes in respiratory system mechanics and modified cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation in animals without previous lung injury.
Identifying Potential Ventilator Auto-Triggering Among Organ Procurement Organization Referrals.
Henry, Nicholas R; Russian, Christopher J; Nespral, Joseph
2016-06-01
Ventilator auto-trigger is the delivery of an assisted mechanical ventilated breath over the set ventilator frequency in the absence of a spontaneous inspiratory effort and can be caused by inappropriate ventilator trigger sensitivity. Ventilator auto-trigger can be misinterpreted as a spontaneous breath and has the potential to delay or prevent brain death testing and confuse health-care professionals and/or patient families. To determine the frequency of organ donor referrals from 1 Organ Procurement Organization (OPO) that could benefit from an algorithm designed to assist organ recovery coordinators to identify and correct ventilator auto-triggering. This retrospective analysis evaluated documentation of organ donor referrals from 1 OPO in central Texas during the 2013 calendar year that resulted in the withdrawal of care by the patient's family and the recovery of organs. The frequency of referrals that presented with absent brain stem reflexes except for additional respirations over the set ventilator rate was determined to assess for the need of the proposed algorithm. Documentation of 672 organ procurement organization referrals was evaluated. Documentation from 42 referrals that resulted in the withdrawal of care and 21 referrals that resulted in the recovery of organs were identified with absent brain stem reflexes except for spontaneous respirations on the mechanical ventilator. As a result, an algorithm designed to identify and correct ventilator auto-trigger could have been used 63 times during the 2013 calendar year. © 2016, NATCO.
Heliox Improves Carbon Dioxide Removal during Lung Protective Mechanical Ventilation.
Beurskens, Charlotte J; Brevoord, Daniel; Lagrand, Wim K; van den Bergh, Walter M; Vroom, Margreeth B; Preckel, Benedikt; Horn, Janneke; Juffermans, Nicole P
2014-01-01
Introduction. Helium is a noble gas with low density and increased carbon dioxide (CO2) diffusion capacity. This allows lower driving pressures in mechanical ventilation and increased CO2 diffusion. We hypothesized that heliox facilitates ventilation in patients during lung-protective mechanical ventilation using low tidal volumes. Methods. This is an observational cohort substudy of a single arm intervention study. Twenty-four ICU patients were included, who were admitted after a cardiac arrest and mechanically ventilated for 3 hours with heliox (50% helium; 50% oxygen). A fixed protective ventilation protocol (6 mL/kg) was used, with prospective observation for changes in lung mechanics and gas exchange. Statistics was by Bonferroni post-hoc correction with statistical significance set at P < 0.017. Results. During heliox ventilation, respiratory rate decreased (25 ± 4 versus 23 ± 5 breaths min(-1), P = 0.010). Minute volume ventilation showed a trend to decrease compared to baseline (11.1 ± 1.9 versus 9.9 ± 2.1 L min(-1), P = 0.026), while reducing PaCO2 levels (5.0 ± 0.6 versus 4.5 ± 0.6 kPa, P = 0.011) and peak pressures (21.1 ± 3.3 versus 19.8 ± 3.2 cm H2O, P = 0.024). Conclusions. Heliox improved CO2 elimination while allowing reduced minute volume ventilation in adult patients during protective mechanical ventilation.
Kettemann, Dagmar; Funke, Andreas; Maier, André; Rosseau, Simone; Meyer, Robert; Spittel, Susanne; Münch, Christoph; Meyer, Thomas
2017-02-01
Non-invasive ventilation (NIV) or tracheotomy with invasive ventilation (TIV) are treatment options in ALS. However, a proportion of patients receiving long-term ventilation decide to have it withdrawn. The objective of this study was to analyse the clinical characteristics and palliative approaches in ALS patients withdrawing from long-term ventilation (WLTV). In a cohort study, two different palliative concepts in WLTV were studied: (1) augmented symptom control (ASC; sedation not intended) in patients with ventilator-free tolerance; (2) continuous deep sedation (CDS; sedation intended) in patients without ventilator-free tolerance. Results showed that WLTV was realised in 49 ALS patients (NIV = 13; TIV = 36). Mean daily ventilation was 23.4 h. The ALS Functional Rating Scale (ALSFRS-R) was low (5.6 of 48). Forty-one per cent of patients (n = 20) presented with ophthalmoplegia. ASC was performed in 20 patients, CDS in 29 patients. The mean time to death following disconnection was 32 (0.3-164) h during ASC and 0.3 (0.2-0.6) h in CDS. In conclusion, a low ALSFRS-R, high incidence of ophthalmoplegia and extended ventilator dependency were found before WLTV. The presence or absence of ventilator-free tolerance determined the approach to the management of symptoms, the setting for immediate end-of-life care and the course of dying in WLTV.
Stewart, Claire; Shoemaker, Jamie; Keller-Smith, Rachel; Edmunds, Katherine; Davis, Andrew; Tegtmeyer, Ken
2017-10-16
Pediatric code blue activations are infrequent events with a high mortality rate despite the best effort of code teams. The best method for training these code teams is debatable; however, it is clear that training is needed to assure adherence to American Heart Association (AHA) Resuscitation Guidelines and to prevent the decay that invariably occurs after Pediatric Advanced Life Support training. The objectives of this project were to train a multidisciplinary, multidepartmental code team and to measure this team's adherence to AHA guidelines during code simulation. Multidisciplinary code team training sessions were held using high-fidelity, in situ simulation. Sessions were held several times per month. Each session was filmed and reviewed for adherence to 5 AHA guidelines: chest compression rate, ventilation rate, chest compression fraction, use of a backboard, and use of a team leader. After the first study period, modifications were made to the code team including implementation of just-in-time training and alteration of the compression team. Thirty-eight sessions were completed, with 31 eligible for video analysis. During the first study period, 1 session adhered to all AHA guidelines. During the second study period, after alteration of the code team and implementation of just-in-time training, no sessions adhered to all AHA guidelines; however, there was an improvement in percentage of sessions adhering to ventilation rate and chest compression rate and an improvement in median ventilation rate. We present a method for training a large code team drawn from multiple hospital departments and a method of assessing code team performance. Despite subjective improvement in code team positioning, communication, and role completion and some improvement in ventilation rate and chest compression rate, we failed to consistently demonstrate improvement in adherence to all guidelines.
Mechanical ventilation and sepsis impair protein metabolism in the diaphragm of neonatal pigs
USDA-ARS?s Scientific Manuscript database
Mechanical ventilation (MV) impairs diaphragmatic function and diminishes the ability to wean from ventilatory support in adult humans. In normal neonatal pigs, animals that are highly anabolic, endotoxin (LPS) infusion induces sepsis, reduces peripheral skeletal muscle protein synthesis rates, but ...
Long-Term Adaptive Servo-Ventilator Treatment Prevents Cardiac Death and Improves Clinical Outcome.
Imamura, Teruhiko; Kinugawa, Koichiro; Nitta, Daisuke; Komuro, Issei
2016-01-01
Adaptive servo-ventilation (ASV) is a recently developed, noninvasive therapeutic tool for the treatment of heart failure (HF). However, the efficacy of ASV therapy in patients with advanced HF remains uncertain, especially as regards its contribution to freedom from cardiac replacement therapy. A total of 85 patients with advanced HF (New York Heart Association [NYHA] class IV 71%, inotrope infusion-dependent 34%) refractory to guideline-directed medical therapy, received ASV therapy, irrespective of sleep-disordered breathing, at our institute between 2008 and 2014. Among these 85 patients, 46 continued ASV therapy for > 1 month (continued group), whereas 39 discontinued the therapy after < 1 month because of intolerance (discontinued group). There were no significant differences in baseline variables between the two groups. Heart rate indicating sympathetic activity, left ventricular (LV) reverse remodeling assessed by LV diastolic diameter, LV ejection fraction, and the grades of mitral and tricuspid regurgitations, HF severity assessed by NYHA class and plasma level of B-type natriuretic peptide, and end-organ dysfunction, improved significantly at 6 months following the initiation of ASV therapy (P < 0.05 for all). All-cause mortality and cardiac death rate were significantly lower during 2-year follow up in the continued group (P < 0.05 for both). In conclusion, ASV is a novel therapeutic tool prior to cardiac replacement therapy in patients with advanced HF and may prolong the period until cardiac replacement therapy becomes necessary.
Patel, Sameer; Li, Jiayu; Pandey, Apoorva; Pervez, Shamsh; Chakrabarty, Rajan K; Biswas, Pratim
2017-01-01
Many households use solid fuels for cooking and heating purposes. There is currently a knowledge gap in our understanding of the variations in indoor air quality throughout the household as most of the studies focus on the areas in the close proximity of the cookstove. A low-cost wireless particulate matter (PM) sensor network was developed and deployed in households in Raipur, India to establish the spatio-temporal variation of PM concentrations. The data from multiple sensors were acquired in real-time with a wireless system. Data collected from the sensors agreed well (R 2 =0.713) with the reference data collected from a commercially available instrument. Low spatial variability was observed within the kitchen due to its small size and poor ventilation - a common feature of most rural Indian kitchens. Due to insufficient ventilation from open doors and windows, high PM concentrations similar to those found in the kitchen were also found in the adjoining rooms. The same household showed significantly different post-extinguished cookstove PM concentration decay rates (0.26mg/m 3 -min and 0.87mg/m 3 -min) on different days, owing to varying natural air exchange rates (7.68m 3 /min and 37.40m 3 /min). Copyright © 2016 Elsevier Inc. All rights reserved.
Ventilation and infiltration in high-rise apartment buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diamond, R.C.; Feustel, H.E.; Dickerhoff, D.J.
1996-03-01
Air flow, air leakage measurements and numerical simulations were made on a 13-story apartment building to characterize the ventilation rates for the individual apartments. Parametric simulations were performed for specific conditions, e.g., height, orientation, outside temperature and wind speed. Our analysis of the air flow simulations suggest that the ventilation to the individual units varies considerably. With the mechanical ventilation system disabled and no wind, units at the lower level of the building have adequate ventilation only on days with high temperature differences, while units on higher floors have no ventilation at all. Units facing the windward side will bemore » over-ventilated when the building experiences wind directions between west and north. At the same time, leeward apartments did not experience any fresh air-because, in these cases, air flows enter the apartments from the corridor and exit through the exhaust shafts and the cracks in the facade. Even with the mechanical ventilation system operating, we found wide variation in the air flows to the individual apartments. In addition to the specific case presented here, these findings have more general implications for energy retrofits and health and comfort of occupants in high-rise apartment buildings.« less
On the Use of Windcatchers in Schools: Climate Change, Occupancy Patterns, and Adaptation Strategies
Mumovic, D.
2009-01-01
Advanced naturally ventilated systems based on integration of basic natural ventilation strategies such as cross-ventilation and stack effect have been considered to be a key element of sustainable design. In this respect, there is a pressing need to explore the potential of such systems to achieve the recommended occupant comfort targets throughout their lifetime without relying on mechanical means. This study focuses on use of a windcatcher system in typical classrooms which are usually characterized by high and intermittent internal heat gains. The aims of this paper are 3-fold. First, to describe a series of field measurements that investigated the ventilation rates, indoor air quality, and thermal comfort in a newly constructed school located at an urban site in London. Secondly, to investigate the effect of changing climate and occupancy patterns on thermal comfort in selected classrooms, while taking into account adaptive potential of this specific ventilation strategy. Thirdly, to assess performance of the ventilation system using the newly introduced performance-based ventilation standards for school buildings. The results suggest that satisfactory occupant comfort levels could be achieved until the 2050s by a combination of advanced ventilation control settings and informed occupant behavior. PMID:27110216
NASA Astrophysics Data System (ADS)
Krawczyk, Piotr
2013-12-01
Controlling low-temperature drying facilities which utilise nonprepared air is quite difficult, due to very large variability of ventilation air parameters - both in daily and seasonal cycles. The paper defines the concept of cumulative drying potential of ventilation air and presents experimental evidence that there is a relation between this parameter and condition of the dried matter (sewage sludge). Knowledge on current dry mass content in the dried matter (sewage sludge) provides new possibilities for controlling such systems. Experimental data analysed in the paper was collected in early 2012 during operation of a test solar drying facility in a sewage treatment plant in Błonie near Warsaw, Poland.
Ward, Shan L; Quinn, Carson M; Valentine, Stacey L; Sapru, Anil; Curley, Martha A Q; Willson, Douglas F; Liu, Kathleen D; Matthay, Michael A; Flori, Heidi R
2016-10-01
To determine the frequency of low-tidal volume ventilation in pediatric acute respiratory distress syndrome and assess if any demographic or clinical factors improve low-tidal volume ventilation adherence. Descriptive post hoc analysis of four multicenter pediatric acute respiratory distress syndrome studies. Twenty-six academic PICU. Three hundred fifteen pediatric acute respiratory distress syndrome patients. All patients who received conventional mechanical ventilation at hours 0 and 24 of pediatric acute respiratory distress syndrome who had data to calculate ideal body weight were included. Two cutoff points for low-tidal volume ventilation were assessed: less than or equal to 6.5 mL/kg of ideal body weight and less than or equal to 8 mL/kg of ideal body weight. Of 555 patients, we excluded 240 for other respiratory support modes or missing data. The remaining 315 patients had a median PaO2-to-FIO2 ratio of 140 (interquartile range, 90-201), and there were no differences in demographics between those who did and did not receive low-tidal volume ventilation. With tidal volume cutoff of less than or equal to 6.5 mL/kg of ideal body weight, the adherence rate was 32% at hour 0 and 33% at hour 24. A low-tidal volume ventilation cutoff of tidal volume less than or equal to 8 mL/kg of ideal body weight resulted in an adherence rate of 58% at hour 0 and 60% at hour 24. Low-tidal volume ventilation use was no different by severity of pediatric acute respiratory distress syndrome nor did adherence improve over time. At hour 0, overweight children were less likely to receive low-tidal volume ventilation less than or equal to 6.5 mL/kg ideal body weight (11% overweight vs 38% nonoverweight; p = 0.02); no difference was noted by hour 24. Furthermore, in the overweight group, using admission weight instead of ideal body weight resulted in misclassification of up to 14% of patients as receiving low-tidal volume ventilation when they actually were not. Low-tidal volume ventilation is underused in the first 24 hours of pediatric acute respiratory distress syndrome. Age, Pediatric Risk of Mortality-III, and pediatric acute respiratory distress syndrome severity were not associated with improved low-tidal volume ventilation adherence nor did adherence improve over time. Overweight children were less likely to receive low-tidal volume ventilation strategies in the first day of illness.
Indoor air quality in a middle school, Part I: Use of CO2 as a tracer for effective ventilation.
Scheff, P A; Paulius, V K; Huang, S W; Conroy, L M
2000-11-01
The overall objective of the study was to evaluate the indoor air quality at a middle school with an emphasis on characterizing baseline conditions. The focus of this article is on the relationship between occupancy and measured concentrations of carbon dioxide, and an evaluation of the use of carbon dioxide as a tracer for ventilation in the school. The school was characterized as having no health complaints, good maintenance schedules, no carpeting within the classrooms or hallways, and no significant remodeling, and its officials had agreed to allow the sampling to take place during school hours. Monitoring followed the guidelines recommended in the "Preliminary Draft: Conceptual Standardized EPA Protocol For Characterizing Indoor Air Quality in School Buildings." Four indoor locations including the cafeteria, a science classroom, an art classroom, and the lobby outside the main office, and one outdoor location were sampled for various environmental comfort and pollutant parameters for one week in February 1997. A consistent relationship between hourly occupancy and corresponding carbon dioxide concentrations was seen. Carbon dioxide concentrations in the cafeteria, art room, and lobby were within specified American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) guidelines for comfort (< 1000 ppm). The science room had the highest concentrations (frequently exceeding 1000 ppm) due to high occupancy and non-functioning unit ventilators. Measured ventilation rates were within specified ASHRAE guidelines for the art room, cafeteria, and lobby. The science room, which relied on natural ventilation only, was not able to meet the ASHRAE guideline on one of the three days studied. The use of a completely mixed space, one compartment mass balance model with estimated CO2 generation rates and measured CO2 concentrations is shown to be a useful method for evaluating ventilation. Modeled effective ventilation, air changes per hour, and mixing factors reflected measured carbon dioxide concentrations and measured ventilation in each room. Mechanical ventilation afforded better mixing than natural ventilation. This study demonstrates the usefulness of collecting indoor CO2 and occupancy data when carrying out indoor air quality evaluations in schools.
Cardiopulmonary readjustments in passive tilt
NASA Technical Reports Server (NTRS)
Matalon, S. V.; Farhi, L. E.
1979-01-01
The readjustment of cardiopulmonary variables in human volunteers at various tilt angles on a tilt board is studied. Five healthy subjects (18-31 yr) with thorough knowledge of the experimental protocol are tested, passively tilted from the supine to the upright position in 15-deg increments in random sequence. The parameters measured are cardiac output (Q), heart rate (HR), stroke volume (SV), minute and alveolar ventilation /V(E) and V(A)/, functional residual capacity (FRC), and arterial-end-tidal P(CO2) pressure difference. It is found that changes in Q and FRC are linearly related to the sine of the tilt angle, indicating that either reflexes are absent or their net effect is proportional to the effects of gravity. This is clearly not the case for other variables /HR, SV, V(E), V(A)/, where it is possible to demonstrate threshold values for the appearance of secondary changes.
Martinez, Enid E; Bechard, Lori J; Smallwood, Craig D; Duggan, Christopher P; Graham, Robert J; Mehta, Nilesh M
2015-07-01
Diet modification may improve body composition and respiratory variables in children with respiratory insufficiency. Our objective was to examine the effect of an individualized diet intervention on changes in weight, lean body mass, minute ventilation, and volumetric CO2 production in children dependent on long-term mechanical ventilatory support. Prospective, open-labeled interventional study. Study subjects' homes. Children, 1 month to 17 years old, dependent on at least 12 hr/d of transtracheal mechanical ventilatory support. Twelve weeks of an individualized diet modified to deliver energy at 90-110% of measured energy expenditure and protein intake per age-based guidelines. During a multidisciplinary home visit, we obtained baseline values of height and weight, lean body mass percent by bioelectrical impedance analysis, actual energy and protein intake by food record, and measured energy expenditure by indirect calorimetry. An individualized diet was then prescribed to optimize energy and protein intake. After 12 weeks on this interventional diet, we evaluated changes in weight, height, lean body mass percent, minute ventilation, and volumetric CO2 production. Sixteen subjects, mean age 9.3 years (SD, 4.9), eight male, completed the study. For the diet intervention, a majority of subjects required a change in energy and protein prescription. The mean percentage of energy delivered as carbohydrate was significantly decreased, 51.7% at baseline versus 48.2% at follow-up, p = 0.009. Mean height and weight increased on the modified diet. Mean lean body mass percent increased from 58.3% to 61.8%. Minute ventilation was significantly lower (0.18 L/min/kg vs 0.15 L/min/kg; p = 0.04), and we observed a trend toward lower volumetric CO2 production (5.4 mL/min/kg vs 5.3 mL/min/kg; p = 0.06) after 12 weeks on the interventional diet. Individualized diet modification is feasible and associated with a significant decrease in minute ventilation, a trend toward significant reduction in CO2 production, and improved body composition in children on long-term mechanical ventilation. Optimization of respiratory variables and lean body mass by diet modification may benefit children with respiratory insufficiency in the ICU.
Driving pressure and survival in the acute respiratory distress syndrome.
Amato, Marcelo B P; Meade, Maureen O; Slutsky, Arthur S; Brochard, Laurent; Costa, Eduardo L V; Schoenfeld, David A; Stewart, Thomas E; Briel, Matthias; Talmor, Daniel; Mercat, Alain; Richard, Jean-Christophe M; Carvalho, Carlos R R; Brower, Roy G
2015-02-19
Mechanical-ventilation strategies that use lower end-inspiratory (plateau) airway pressures, lower tidal volumes (VT), and higher positive end-expiratory pressures (PEEPs) can improve survival in patients with the acute respiratory distress syndrome (ARDS), but the relative importance of each of these components is uncertain. Because respiratory-system compliance (CRS) is strongly related to the volume of aerated remaining functional lung during disease (termed functional lung size), we hypothesized that driving pressure (ΔP=VT/CRS), in which VT is intrinsically normalized to functional lung size (instead of predicted lung size in healthy persons), would be an index more strongly associated with survival than VT or PEEP in patients who are not actively breathing. Using a statistical tool known as multilevel mediation analysis to analyze individual data from 3562 patients with ARDS enrolled in nine previously reported randomized trials, we examined ΔP as an independent variable associated with survival. In the mediation analysis, we estimated the isolated effects of changes in ΔP resulting from randomized ventilator settings while minimizing confounding due to the baseline severity of lung disease. Among ventilation variables, ΔP was most strongly associated with survival. A 1-SD increment in ΔP (approximately 7 cm of water) was associated with increased mortality (relative risk, 1.41; 95% confidence interval [CI], 1.31 to 1.51; P<0.001), even in patients receiving "protective" plateau pressures and VT (relative risk, 1.36; 95% CI, 1.17 to 1.58; P<0.001). Individual changes in VT or PEEP after randomization were not independently associated with survival; they were associated only if they were among the changes that led to reductions in ΔP (mediation effects of ΔP, P=0.004 and P=0.001, respectively). We found that ΔP was the ventilation variable that best stratified risk. Decreases in ΔP owing to changes in ventilator settings were strongly associated with increased survival. (Funded by Fundação de Amparo e Pesquisa do Estado de São Paulo and others.).
Chigurupati, Keerthi; Gadhinglajkar, Shrinivas; Sreedhar, Rupa; Nair, Muraleedharan; Unnikrishnan, Madathipat; Pillai, Manjusha
2018-02-01
To determine the criteria for postoperative mechanical ventilation after thymectomy in patients with Myasthenia Gravis. Retrospective study. Teritiary care centre. 77 Myasthenia gravis patients operated for thymectomy were studied. After obtaining clearance from Institutional ethics committee, medical records of 77 patients with MG, who were operated for thymectomy between January 2005 and December 2015 were reviewed in a retrospective manner. Perioperative variables collected from the patient records were demographic data, duration of the disease, Osserman and Genkin classification, Anti-acetylcholine antibody (AChR) positivity, preoperative daily dose of drug, history of preoperative myasthenic crisis, preoperative vital capacity, technique of anesthesia, drugs used for anesthesia, perioperative complications, and duration of postoperative mechanical ventilation. The patients were divided into two groups, group I and group II consisting of those who required postoperative ventilation for < 300 minutes and > 300 minutes, respectively. The determinants of prolonged postoperative ventilation were studied. The requirement of mechanical ventilation was higher in patients with higher Osserman's grade of myasthenia gravis. Duration of the disease had no effect on the duration of mechanical ventilation in myasthenic patients post thymectomy (p = 0.89). The patients with a preoperative history of myasthenic crisis had a requirement for prolonged mechanical ventilation (p=0.03). Patients with preoperative vital capacity < 2.9 litres and preoperative CT scan showing thymoma had a requirement for prolonged mechanical ventilation with p values < 0.001 and 0.035, respectively. Patients who showed positivity for anti-acetylcholine antibodies had a prolonged mechanical ventilation (p=0.026). Preoperative dose of pyridostigmine and the choice of continuation or discontinuation of antcholinesterases on the day of surgery had no influence on the duration of mechanical ventilation (p value of 0.19 and 0.36 respectively). Epidural analgesia intra and postoperatively significantly reduced the requirement of mechanical ventilation (p=0.006). The predictors of postoperative ventilation in myasthenic patients undergoing thymectomy as per our study are: 1. Grade of myasthenia; 2. History of preoperative myasthenic crisis; 3. Anti-acetylcholine antibodies positivity; 4. Presence of thymoma; and 5. a vital capacity < 2.9 litres. Use of thoracic epidural as a part of combined anesthetic technique helps to reduce the need of mechanical ventilation in these patients. Copyright © 2018 Elsevier Inc. All rights reserved.
Weireter, Leonard J; Collins, J N; Britt, Rebecca C; Reed, Scott F; Novosel, T J; Britt, L D
2009-05-01
Ventilator-associated pneumonia (VAP) remains a major source of morbidity, mortality, and expense in the ICU despite therapies directed against it. A retrospective review of a prospectively developed performance-improvement project monitoring the incidence of VAP in two adjacent ICUs was conducted. In response to an excessive VAP rate, weekly multidisciplinary team meetings were instituted to review data, develop care protocols, and modify care routines. Protocol compliance was monitored daily and feedback provided weekly to the care teams. VAP rates were determined by the institutional Infection Control Committee and reviewed monthly with the ICU multidisciplinary team. Duration of the investigational period was 10 years. A standardized ventilator-weaning protocol was instituted with confirmed 95% use. Additional modifications of care, such as patient positioning, use of specific endotracheal tubes to minimize aspiration of supraglottic secretions, an oral-care regimen, and aggressive antibiotic stewardship were standardized, with a compliance rate >90%. VAP rates dropped from 12.8 per 1,000 patient-days in 1998 to 1.1 in 2007 in the burn trauma ICU and from 21.2 to <1 in the neurotrauma ICU in the same time frame. Also, mean ventilator length of stay decreased from 6 days to 4.2 and from 5.8 days to 4.75 simultaneously in the respective ICUs. Such performance improvement has been sustained since implementation of the program. A systematic, monitored program of standardized care protocols can markedly reduce VAP rate in the ICU.
Ojeda Castillejo, Elena; de Lucas Ramos, Pilar; López Martin, Soledad; Resano Barrios, Pilar; Rodríguez Rodríguez, Paula; Morán Caicedo, Liliana; Bellón Cano, José María; Rodriguez Gonzalez-Moro, José Miguel
2015-02-01
Obesity is associated with 2 closely related respiratory diseases: obesity hypoventilation syndrome (OHS) and obstructive sleep apnea-hypopnea syndrome (OSAHS). It has been shown that noninvasive ventilation during sleep produces clinical and functional improvement in these patients. The long-term survival rate with this treatment, and the difference in clinical progress in OHS patients with and without OSAHS are analyzed. Longitudinal, observational study with a cohort of patients diagnosed with OHS, included in a home ventilation program over a period of 12 years, divided into 2 groups: pure OHS and OSAHS-associated OHS. Bi-level positive airway pressure ventilation was administered. During the follow-up period, symptoms, exacerbations and hospitalizations, blood gas tests and pulmonary function tests, and survival rates were monitored and compared. Eighty-three patients were eligible for analysis, 60 women (72.3%) and 23 men (27.7%), with a mean survival time of 8.47 years. Fifty patients (60.2%) were included in the group without OSAHS (OHS) and 33 (39.8%) in the OSAHS-associated OHS group (OHS-OSAHS). PaCO₂ in the OHS group was significantly higher than in the OHS-OSAHS group (P<.01). OHS patients also had a higher hospitalization rate (P<.05). There was a significant improvement in both groups in FEV₁ and FVC, and no differences between groups in PaCO₂ and PaO₂ values. There were no differences in mortality between the 2 groups, but low FVC values were predictive of mortality. The use of mechanical ventilation in patients with OHS, with or without OSAHS, is an effective treatment for the correction of blood gases and functional alterations and can achieve prolonged survival rates. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.
Roberts, Nesta; Moule, Pam
2011-01-01
Ventilator-associated pneumonia (VAP) is a common complication of mechanical ventilation after endotracheal intubation. The role of chlorhexidine and tooth-brushing has been considered as a clinical intervention to reduce infection rates, however, evidence to inform this needs appraising. This paper presents a critical review on the effect of chlorhexidine gluconate (CHX) and tooth-brushing in decreasing rates of VAP in mechanically ventilated adult patients cared for in intensive care settings. A literature search was conducted using a number of bibliographic databases (n = 6). A number of parameters were used to exclude irrelevant papers. A total n = 17 papers were located and accessed, which were directly related to the field. Eight studies that met the criteria and addressed the study aims were reviewed. CHX was successful in reducing the rate of VAP and using a combination of CHX and colistine resulted in better oropharyngeal decontamination which reduced and delayed VAP. Chlorhexidine was also effective in reducing dental plaque in patients cared for in intensive care and had the potential to reduce nosocomial infections. Results of studies investigating the use of tooth-brushing in reducing VAP incidence proved inconsistent, although all recommend tooth-brushing as important in maintaining good oral hygiene. The use of chlorhexidine has been proven to be of some value in reducing VAP, although may be more effective when used with a solution which targets gram-negative bacteria. Tooth-brushing is recommended in providing a higher standard of oral care to mechanically ventilated patients and reducing VAP when used with chlorhexidine. However, limitations in study design and inconsistency in results suggest that further research is required into the effects of tooth-brushing. © 2011 The Authors. Nursing in Critical Care © 2011 British Association of Critical Care Nurses.
Simple, Inexpensive Model Spirometer for Understanding Ventilation Volumes
ERIC Educational Resources Information Center
Giuliodori, Mauricio J.; DiCarlo, Stephen E.
2004-01-01
Spirometers are useful for enhancing students' understanding of normal lung volumes, capacities, and flow rates. Spirometers are also excellent for understanding how lung diseases alter ventilation volumes. However, spirometers are expensive, complex, and not appropriate for programs with limited space and budgets. Therefore, we developed a…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendell, Mark J.; Apte, Mike G.
This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptivemore » ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These strategies, however, would make it more complex and more prescriptive, and would require substantial research. One practical intermediate strategy to save energy would be an alternate VRP, allowing VRs lower than currently prescribed, as long as indoor VOC concentrations were no higher than with VRs prescribed under the current VRP. This kind of hybrid, with source reduction and use of air cleaning optional but permitted, could eventually evolve, as data, materials, and air-cleaning technology allowed gradual lowering of allowable concentrations, into a fully developed IAQP. Ultimately, it seems that VR standards must evolve to resemble the IAQP, especially in California, where buildings must achieve zero net energy use within 20 years.« less
Thomachot, L; Vialet, R; Arnaud, S; Barberon, B; Michel-Nguyen, A; Martin, C
1999-05-01
To compare the efficiency of two heat and moisture exchange filters (HMEFs) of different compositions of the humidifying capacity and the rate of bronchial colonization and ventilator-associated pneumonia in patients in the intensive care unit (ICU). Prospective, randomized study. ICU of a university hospital. All patients who required mechanical ventilation for 24 hrs or more during the study period. At admission to the ICU, patients were randomly assigned to one of two groups. In one group, the patients were ventilated with Humid-Vent Filter Light HMEF. The condensation surface was made of paper impregnated with CaCl2. The filter membrane was made of polypropylene. In the other group, the patients were ventilated with the Clear ThermAl HMEF (Intersurgical, France). The condensation surface was made of plastic foam impregnated with AlCl2. The filter membrane was made of two polymer fibers (modacrylic and polypropylene). In both groups, HMEFs were changed daily. Seventy-seven patients were ventilated for 19+/-7 days with the Humid-Vent Filter Light HMEF and 63 patients for 17+/-6 days with the Clear ThermAl HMEF. Patients ventilated with the Humid-Vent Filter Light underwent 8.7+/-3.7 tracheal aspirations and 1.2+/-2.0 instillations per day and those with the Clear ThermAl, 8.2+/-3.9 and 1.5+/-2.4 per day, respectively (NS). The abundance of tracheal secretions and the presence of blood and viscosity, as evaluated by semiquantitative scales, were similar in both groups. One episode of tracheal tube occlusion was observed with the Humid-Vent Filter Light HMEF and none with the other HMEF (NS). Tracheal colonization was observed at a rate of 91% with the Humid-Vent Filter Light and 97% with the Clear ThermAl (NS). The rate of ventilator-associated pneumonia was similar in both groups (35%). Bacteria responsible for tracheal colonization and pneumonia were similar in both groups. Despite differences in their components, the two HMEFs that were tested achieved similar performances in terms of humidification and heating of inspired gases. Only one episode of endotracheal tube occlusion was detected, and very few patients (three in each group) had to be switched to an active heated humidifier. No difference was observed either in the rate of tracheal colonization or of ventilator-associated pneumonia. These data show that the Humid-Vent Filter Light and the Clear ThermAl HMEFs are suited for use with ICU patients.
Parissopoulos, Stelios; Mpouzika, Meropi DA; Timmins, Fiona
2017-01-01
Adult respiratory distress syndrome (ARDS) is a type of acute diffuse lung injury characterized by severe inflammation, increased pulmonary vascular permeability and a loss of aerated lung tissue. The effects of high fraction of inspired oxygen (FiO 2 ) include oxygen toxicity manifested by damage to the lung parenchyma in the acute phase of lung injury. There is still a high mortality rate among this group of patients, so clinically sensitive evidence-based interventions are paramount to maximize survival chances during critical care. The aim of this article is to explore the current opinion concerning optimal mechanical ventilation support techniques for patients with acute respiratory distress syndrome. A literature search of clinical trials and observation studies, reviews, discussion papers, meta-analyses and clinical guidelines written in English up to 2015, derived from the databases of Scopus, CINAHL, Cochrane Library databases and PubMed was conducted. Low tidal volume, pressure limitation and prone positioning in severe ARDS patients appear to be of some benefit. More research is required and further development and use of standardized protocols is an important strategy for reducing practice variations across disciplines, as well as giving clear guidelines to nurses practising in critical care. There is also evidence that this syndrome is under-diagnosed and the utilization of lung protective ventilation is still variable. It is important that nurses have underlying knowledge of both aetiology of ARDS and ventilation management, and that they monitor patients very closely. The adoption of a low tidal ventilation protocol, which is based on quality evidence guidelines, the value of rescue therapies and patient observation practices in the overall patient management, and the need to place emphasis on long-term patient outcomes, all these emerge as key factors for consideration and future research. However, there is also a need for more research that would explore the unique contribution of nurses in the management of this patient group, as it is difficult to discern this in the current literature. © 2015 British Association of Critical Care Nurses.
The transmission characteristics of indoor particles under different ventilation conditions
NASA Astrophysics Data System (ADS)
Lv, Yang; Wang, Haifeng; Wei, Shanshan
2017-11-01
In modern society, ventilation is an important method for removing indoor particles. This study applies the parameter of attenuation index to analyze the effect of the removal of indoor particles in the two typical ventilation strategies called ceiling exhaust and slit exhaust strategy. Experiment was conducted in a chamber and riboflavin particles were used as the indoor particles source, instantaneous microbial detection (IMD) used to measure the particulate concentration. Conclusions can be found that air exchange rate is an important factor affecting the indoor particle concentration distribution. In the process of indoor free settling(air exchange rate is 0 h-1), the deposition rate were 0.086 h-1, 0.122 h-1, 0.173 h-1 for the particles of 0.5-1.0 μm, 1.0-3.0μm and 3.0-5.0 μm. When the air exchange rate increased to 2.5 h-1, the differences in the attenuation index is significant. There was also a significant linear relationship between air exchange rate and attenuation index. Furthermore, the effect of the slit exhaust strategy on the removal of coarse particles is more remarkable as the increasing air exchange rate.
Impact of particle emissions of new laser printers on modeled office room
NASA Astrophysics Data System (ADS)
Koivisto, Antti J.; Hussein, Tareq; Niemelä, Raimo; Tuomi, Timo; Hämeri, Kaarle
2010-06-01
In this study, we present how an indoor aerosol model can be used to characterize particle emitter and predict influence of the source on indoor air quality. Particle size-resolved emission rates were quantified and the source's influence on indoor air quality was estimated by using office model simulations. We measured particle emissions from three modern laser printers in a flow-through chamber. Measured parameters were used as input parameters for an indoor aerosol model, which we then used to quantify the particle emission rates. The same indoor aerosol model was used to simulate the effect of the particle emission source inside an office model. The office model consists of a mechanically ventilated empty room and the particle source. The aerosol from the ventilation air was a filtered urban background aerosol. The effect of the ventilation rate was studied using three different ventilation ratios 1, 2 and 3 h -1. According to the model, peak emission rates of the printers exceeded 7.0 × 10 8 s -1 (2.5 × 10 12 h -1), and emitted mainly ultrafine particles (diameter less than 100 nm). The office model simulation results indicate that a print job increases ultrafine particle concentration to a maximum of 2.6 × 10 5 cm -3. Printer-emitted particles increased 6-h averaged particle concentration over eleven times compared to the background particle concentration.
Hunter, Bryan C; Oliva, Rosemary; Sahler, Olle Jane Z; Gaisser, D'Arcy; Salipante, Diane M; Arezina, Clare H
2010-01-01
This project investigated music therapy (MT) in managing anxiety associated with weaning from mechanical ventilation. The use of sedation to treat anxiety during weaning is problematic because side effects (e.g., respiratory depression) are precisely the symptoms that cause the weaning process to be interrupted and consequently prolonged. Study goals were to determine the feasibility of incorporating MT into the weaning process and to evaluate the efficacy of the intervention, based on levels of anxiety, Days to Wean (DTW), and patient/nurse satisfaction. Adult patients received multiple MT sessions per week while undergoing weaning trials from mechanical ventilation. Feasibility was determined by successful enrollment in the study and nurse survey. Efficacy was evaluated through anxiety, as measured by heart rate, respiratory rate, and patient/nurse survey; DTW; and patient/nurse satisfaction. Nurse surveys reported that MT was successfully incorporated into the milieu and 61 subjects were enrolled. Significant differences in heart rate and respiratory rate were found from the beginning to the end of MT sessions (p < .05 and p < .0001, respectively), indicating a more relaxed state. No significant difference in mean DTW was found between study and control subjects. Patient/nurse satisfaction was high. Music therapy can be used successfully to treat anxiety associated with weaning from mechanical ventilation. Limitations and suggestions for further research are discussed.
Seasonally-resolved trace element concentrations in stalagmites from a shallow cave in New Mexico
NASA Astrophysics Data System (ADS)
Sekhon, N.; Banner, J.; Miller, N. R.; Carlson, P. E.; Breecker, D.
2017-12-01
High-resolution (sub-annual/seasonal) paleoclimate records extending beyond the instrumental period are required to test climate models and better understand how climate warming/cooling and wetting/drying are manifested seasonally. This is particularly the case for areas such as the southwest United States where precipitation and temperature seasonality dictate the regional climate. Study of a 20thcentury stalagmite (Carlson et al., in prep) documented (1) seasonal variation in trace element compositions of a stalagmite from a shallow, well-ventilated cave and (2) demonstrated the seasonal variation in stalagmite Mg to be in agreement with predicted temperature-dependent fractionation between water and calcite. The seasonal nature of variability was constrained by monitoring the cave on a monthly basis (Casteel and Banner, 2015; Carlson et al., in prep). Here we expand on using stalagmites from shallow, well-ventilated caves as archives of seasonally-resolved climate recorders by studying trace element variations in two coeval modern stalagmites (SBFC-1 and SBFC-2) cored from Sitting Bull Falls, southern New Mexico. Seasonal cycles will be confirmed by analyzing Mg, Ba, and Sr in in-situ calcite precipitated on artificial substrates as available (July, Sept., and Nov. 2017). The chronology is constrained by semi-automated peak counting and 14C bomb-peak. In addition, principal component analyses of trace element data identify two primary underlying modes of trace element variability for soil-derived elements (Cu, Zn, and Fe) and bedrock-derived elements (Mg, Sr, and Ba). We hypothesize that the soil-derived elements are transported by seasonal infiltration of organic colloids and the bedrock-derived elements are controlled by variability in cave air temperature, drip water, and calcite growth rate. The two modes of variability will be calibrated against instrumental data over the 20th century. When complete, these new seasonally resolved proxy records will constrain the pattern and mechanism of the regional climate in southwest United States with a focus on drought indicators.
[Correlation between body mass index and development of pressure ulcers in intensive care medicine].
Catalá Espinosa, A I; Hidalgo Encinas, Y; Cherednichenko, T; Flores Lucas, I; González Tamayo, R; García-Martínez, M Á; Herrero-Gutiérrez, E
2014-01-01
This study aims to evaluate the association between body mass index (BMI), incidence and severity of pressure ulcers (PU) in patients admitted to the Intensive Care Unit (ICU), and describe the differential prognosis of patients with PU and factors that modify it. Case-control study with observation period of 15 months. We collected baseline variables, prognostic scales, therapies and clinical outcome. Univariate analysis was performed for each outcome variable between cases and controls using the appropriate hypothesis test depending on the nature of the variables. ROC curve for BMI and PU. Logistic regression with PU as dependent variable and the covariates that reached p<0.05 in the bivariate analysis. Correlation using Pearson or Spearman was made between BMI, albumin, days to diagnosis of UPP, immobilization, and PU degree. Significance level at p <0.05. 77 patients developed PU and 231 controls were chosen. The cases had higher APACHE II (p=0.043) and SAPS 3 (p=0.023), length of stay in ICU and mechanical ventilation (p<0.001). BMI≥40 was associated with UPP (p=0.024 OR=3.23 CI95% 1.17-8.93). There was a significant association between PU degree, length of stay and MV (p<0,001), but not with immobilization, dynamic support surface and death rate. Multivariate analysis found association between PU, length of MV (p=0.013, OR 1.08, CI95% 1.01-1.16) and kidney replacement therapy (p=0.013, OR 3.55 CI95% 1.31-9.64), with BMI≥40 as a confounding factor. Length of mechanical ventilation and renal replacement therapy are risk factors for pressure ulcer development, and BMI≥40 acts as a confounding factor. PU development and its maximum degree are not associated with a worse prognosis. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
Shimazaki, Yasuhiro; Matsutani, Toshiki; Satsumoto, Yayoi
2016-07-01
Comfort is an important concept in footwear design. The microclimate inside footwear contributes to the perception of thermal comfort. To investigate the effect of ventilation on microclimate formation inside footwear, experiments with subjects were conducted at four gait speeds with three different footwear sizes. Skin temperature, metabolism, and body mass were measured at approximately 25 °C and 50% relative humidity, with no solar radiation and a calm wind. The footwear occupancy and ventilation rate were also estimated, with the latter determined using the tracer gas method. The experimental results revealed that foot movement, metabolism, evaporation, radiation, convection, and ventilation were the main factors influencing the energy balance for temperature formation on the surface of the foot. The cooling effect of ventilation on the arch temperature was observed during gait. The significance of the amount of air space and ventilation on the improvement in the thermal comfort of footwear was clarified. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Environmental physiology of a small marsupial inhabiting arid floodplains.
Warnecke, L; Cooper, C E; Geiser, F; Withers, P C
2010-09-01
Giles' planigale (Planigale gilesi) is among the smallest extant marsupials and inhabits deep soil cracks in arid floodplains. We examined whether its physiology shows specific adaptations to its extreme habitat. Metabolic rate, body temperature, evaporative water loss and thermal conductance were measured for eight planigales (average mass 9 g) exposed to four different ambient temperatures ranging from 10 degrees C to 32 degrees C. Water economy and respiratory variables were measured for the first time in this species. All of these standard physiological variables conformed to allometrically-predicted values for a marsupial. All variables were significantly affected by ambient temperature, except tidal volume and dry thermal conductance. Metabolic rate increased substantially at low ambient temperatures, as required to maintain a relatively constant body temperature of about 32-34 degrees C. This increased oxygen demand was accommodated by increased ventilation rather than increased oxygen extraction. Planigales had a comparatively high point of relative water economy of 19.1 degrees C, consistent with their small body size and arid habitat. Torpor reduced energy expenditure by 79% and evaporative water loss by 62%. Our study suggests that torpor use, along with behavioural adaptations, suffice for P. gilesi to live underground in arid habitats without further physiological adaptations. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Mechanical ventilation and sepsis induce skeletal muscle catabolism in neonatal pigs
USDA-ARS?s Scientific Manuscript database
Reduced rates of skeletal muscle accretion are a prominent feature of the metabolic response to sepsis in infants and children. Septic neonates often require medical support with mechanical ventilation (MV). The combined effects of MV and sepsis in muscle have not been examined in neonates, in whom ...
Water supply rates for recirculating evaporative cooling systems in poultry housing
USDA-ARS?s Scientific Manuscript database
Evaporative cooling (EC) is an important tool to reduce heat stress in animal housing systems. Expansion of ventilation capacity in tunnel ventilated poultry facilities has resulted in increased water demand for EC systems. As water resources become more limited and costly, proper planning and des...
14 CFR 25.1187 - Drainage and ventilation of fire zones.
Code of Federal Regulations, 2014 CFR
2014-01-01
... component containing flammable fluids. The drainage means must be— (1) Effective under conditions expected... flammable vapors. (c) No ventilation opening may be where it would allow the entry of flammable fluids... vapors will cause an additional fire hazard. (e) Unless the extinguishing agent capacity and rate of...
14 CFR 29.1187 - Drainage and ventilation of fire zones.
Code of Federal Regulations, 2012 CFR
2012-01-01
... component containing flammable fluids. The drainage means must be— (1) Effective under conditions expected... flammable vapors. (c) No ventilation opening may be where it would allow the entry of flammable fluids... section of the powerplant compartment) unless the amount of extinguishing agent and the rate of discharge...
14 CFR 25.1187 - Drainage and ventilation of fire zones.
Code of Federal Regulations, 2010 CFR
2010-01-01
... component containing flammable fluids. The drainage means must be— (1) Effective under conditions expected... flammable vapors. (c) No ventilation opening may be where it would allow the entry of flammable fluids... vapors will cause an additional fire hazard. (e) Unless the extinguishing agent capacity and rate of...
14 CFR 25.1187 - Drainage and ventilation of fire zones.
Code of Federal Regulations, 2013 CFR
2013-01-01
... component containing flammable fluids. The drainage means must be— (1) Effective under conditions expected... flammable vapors. (c) No ventilation opening may be where it would allow the entry of flammable fluids... vapors will cause an additional fire hazard. (e) Unless the extinguishing agent capacity and rate of...
14 CFR 29.1187 - Drainage and ventilation of fire zones.
Code of Federal Regulations, 2010 CFR
2010-01-01
... component containing flammable fluids. The drainage means must be— (1) Effective under conditions expected... flammable vapors. (c) No ventilation opening may be where it would allow the entry of flammable fluids... section of the powerplant compartment) unless the amount of extinguishing agent and the rate of discharge...
14 CFR 29.1187 - Drainage and ventilation of fire zones.
Code of Federal Regulations, 2011 CFR
2011-01-01
... component containing flammable fluids. The drainage means must be— (1) Effective under conditions expected... flammable vapors. (c) No ventilation opening may be where it would allow the entry of flammable fluids... section of the powerplant compartment) unless the amount of extinguishing agent and the rate of discharge...
14 CFR 29.1187 - Drainage and ventilation of fire zones.
Code of Federal Regulations, 2013 CFR
2013-01-01
... component containing flammable fluids. The drainage means must be— (1) Effective under conditions expected... flammable vapors. (c) No ventilation opening may be where it would allow the entry of flammable fluids... section of the powerplant compartment) unless the amount of extinguishing agent and the rate of discharge...
14 CFR 29.1187 - Drainage and ventilation of fire zones.
Code of Federal Regulations, 2014 CFR
2014-01-01
... component containing flammable fluids. The drainage means must be— (1) Effective under conditions expected... flammable vapors. (c) No ventilation opening may be where it would allow the entry of flammable fluids... section of the powerplant compartment) unless the amount of extinguishing agent and the rate of discharge...
14 CFR 25.1187 - Drainage and ventilation of fire zones.
Code of Federal Regulations, 2011 CFR
2011-01-01
... component containing flammable fluids. The drainage means must be— (1) Effective under conditions expected... flammable vapors. (c) No ventilation opening may be where it would allow the entry of flammable fluids... vapors will cause an additional fire hazard. (e) Unless the extinguishing agent capacity and rate of...
14 CFR 25.1187 - Drainage and ventilation of fire zones.
Code of Federal Regulations, 2012 CFR
2012-01-01
... component containing flammable fluids. The drainage means must be— (1) Effective under conditions expected... flammable vapors. (c) No ventilation opening may be where it would allow the entry of flammable fluids... vapors will cause an additional fire hazard. (e) Unless the extinguishing agent capacity and rate of...
EFFECTS OF NATURAL AND FORCED BASEMENT VENTILATION ON RADON LEVELS IN SINGLE FAMILY DWELLINGS
The report gives, for the first time, results of an extensive study of the effect of ventilation on radon concentrations and radon entry rate in a single-family dwelling. Measurements of radon concentrations, building dynamics, and environmental parameters made in Princeton Unive...