Petersen, Per H; Lund, Flemming; Fraser, Callum G; Sölétormos, György
2016-11-01
Background The distributions of within-subject biological variation are usually described as coefficients of variation, as are analytical performance specifications for bias, imprecision and other characteristics. Estimation of specifications required for reference change values is traditionally done using relationship between the batch-related changes during routine performance, described as Δbias, and the coefficients of variation for analytical imprecision (CV A ): the original theory is based on standard deviations or coefficients of variation calculated as if distributions were Gaussian. Methods The distribution of between-subject biological variation can generally be described as log-Gaussian. Moreover, recent analyses of within-subject biological variation suggest that many measurands have log-Gaussian distributions. In consequence, we generated a model for the estimation of analytical performance specifications for reference change value, with combination of Δbias and CV A based on log-Gaussian distributions of CV I as natural logarithms. The model was tested using plasma prolactin and glucose as examples. Results Analytical performance specifications for reference change value generated using the new model based on log-Gaussian distributions were practically identical with the traditional model based on Gaussian distributions. Conclusion The traditional and simple to apply model used to generate analytical performance specifications for reference change value, based on the use of coefficients of variation and assuming Gaussian distributions for both CV I and CV A , is generally useful.
Biological variation of vitamins in blood of healthy individuals.
Talwar, Dinesh K; Azharuddin, Mohammed K; Williamson, Cathy; Teoh, Yee Ping; McMillan, Donald C; St J O'Reilly, Denis
2005-11-01
Components of biological variation can be used to define objective quality specifications (imprecision, bias, and total error), to assess the usefulness of reference values [index of individuality (II)], and to evaluate significance of changes in serial results from an individual [reference change value (RCV)]. However, biological variation data on vitamins in blood are limited. The aims of the present study were to determine the intra- and interindividual biological variation of vitamins A, E, B(1), B(2), B(6), C, and K and carotenoids in plasma, whole blood, or erythrocytes from apparently healthy persons and to define quality specifications for vitamin measurements based on their biology. Fasting plasma, whole blood, and erythrocytes were collected from 14 healthy volunteers at regular weekly intervals over 22 weeks. Vitamins were measured by HPLC. From the data generated, the intra- (CV(I)) and interindividual (CV(G)) biological CVs were estimated for each vitamin. Derived quality specifications, II, and RCV were calculated from CV(I) and CV(G). CV(I) was 4.8%-38% and CV(G) was 10%-65% for the vitamins measured. The CV(I)s for vitamins A, E, B(1), and B(2) were lower (4.8%-7.6%) than for the other vitamins in blood. For all vitamins, CV(G) was higher than CV(I), with II <1.0 (range, 0.36-0.95). The RCVs for vitamins were high (15.8%-108%). Apart from vitamins A, B(1), and erythrocyte B(2), the imprecision of our methods for measurement of vitamins in blood was within the desirable goal. For most vitamin measurements in plasma, whole blood, or erythrocytes, the desirable imprecision goals based on biological variation are obtainable by current methodologies. Population reference intervals for vitamins are of limited value in demonstrating deficiency or excess.
Simpson, Aaron J; Potter, Julia M; Koerbin, Gus; Oakman, Carmen; Cullen, Louise; Wilkes, Garry J; Scanlan, Samuel L; Parsonage, William; Hickman, Peter E
2014-06-01
Many patients presenting to the emergency department (ED) for assessment of possible acute coronary syndrome (ACS) have low cardiac troponin concentrations that change very little on repeat blood draw. It is unclear if a lack of change in cardiac troponin concentration can be used to identify acutely presenting patients at low risk of ACS. We used the hs-cTnI assay from Abbott Diagnostics, which can detect cTnI in the blood of nearly all people. We identified a population of ED patients being assessed for ACS with repeat cTnI measurement who ultimately were proven to have no acute cardiac disease at the time of presentation. We used data from the repeat sampling to calculate total within-person CV (CV(T)) and, knowing the assay analytical CV (CV(A)), we could calculate within-person biological variation (CV(i)), reference change values (RCVs), and absolute RCV delta cTnI concentrations. We had data sets on 283 patients. Men and women had similar CV(i) values of approximately 14%, which was similar at all concentrations <40 ng/L. The biological variation was not dependent on the time interval between sample collections (t = 1.5-17 h). The absolute delta critical reference change value was similar no matter what the initial cTnI concentration was. More than 90% of subjects had a critical reference change value <5 ng/L, and 97% had values of <10 ng/L. With this hs-cTnI assay, delta cTnI seems to be a useful tool for rapidly identifying ED patients at low risk for possible ACS. © 2014 The American Association for Clinical Chemistry.
Willems, Philippe; Weekx, Steven; Meskal, Anissa; Schouwers, Sofie
2017-04-01
The measurement of chloride and sodium concentrations in sweat is an important test for the diagnosis of cystic fibrosis (CF). The aim of this study was to assess the analytical variation (CV A ) and within-subject (CV I ) and between-subject (CV G ) biological variation of chloride and sodium concentrations in sweat, collected by pilocarpine iontophoresis and to determine their effect on the clinical interpretation of sweat test results. Twelve Caucasian adults (six male and six female) without symptoms suggestive for CF and with a mean age of 41 years (range 28-59) were included in the study. At least eight samples of sweat were collected from each individual by pilocarpine iontophoresis. Chloride and sodium concentrations were measured in duplicate for each sample using ion selective electrodes. After the removal of outliers, the CV A , CV I , and CV G of chloride and sodium were determined, and their impact on measurement uncertainty and reference change value were calculated. The CV A , CV I , and CV G of chloride in sweat samples were 6.5, 17.7, and 47.2%, respectively. The CV A , CV I , and CV G of sodium sweat samples were 6.0, 17.5, and 42.6%, respectively. Our study indicates that sweat chloride and sodium concentration results must be interpreted with great care. Different components of variation, particularly the biological variations, have a considerable impact on the interpretation of these results. If no pre-analytical, analytical, or post-analytical errors are suspected, repeated sweat testing to confirm first-measurement results might not be desirable.
Ucar, Fatma; Erden, Gonul; Ginis, Zeynep; Ozturk, Gulfer; Sezer, Sevilay; Gurler, Mukaddes; Guneyk, Ahmet
2013-10-01
Available data on biological variation of HbA1c revealed marked heterogeneity. We therefore investigated and estimated the components of biological variation for HbA1c in a group of healthy individuals by applying a recommended and strictly designed study protocol using two different assay methods. Each month, samples were derived on the same day, for three months. Four EDTA whole blood samples were collected from each individual (20 women, 9 men; 20-45 years of age) and stored at -80°C until analysis. HbA1c values were measured by both high performance liquid chromatography (HPLC) (Shimadzu, Prominence, Japan) and boronate affinity chromatography methods (Trinity Biotech, Premier Hb9210, Ireland). All samples were assayed in duplicate in a single batch for each assay method. Estimations were calculated according to the formulas described by Fraser and Harris. The within subject (CV(I))-between subject (CV(G)) biological variations were 1.17% and 5.58%, respectively for HPLC. The calculated CV(I) and CV(G) were 2.15% and 4.03%, respectively for boronate affinity chromatography. Reference change value (RCV) for HPLC and boronate affinity chromatography was 5.4% and 10.4% respectively and individuality index of HbA(1c) was 0.35 and 0.93 respectively. This study for the first time described the components of biological variation for HbA1c in healthy individuals by two different assay methods. Obtained findings showed that the difference between CV(A) values of the methods might considerably affect RCV. These data regarding biological variation of HbA(1c) could be useful for a better evaluation of HbA(1c) test results in clinical interpretation. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Lulu; Liu, Jingling; Li, Yi
2015-03-01
The influence of spatial differences, which are caused by different anthropogenic disturbances, and temporal changes, which are caused by natural conditions, on macroinvertebrates with periphyton communities in Baiyangdian Lake was compared. Periphyton and macrobenthos assemblage samples were simultaneously collected on four occasions during 2009 and 2010. Based on the physical and chemical attributes in the water and sediment, the 8 sampling sites can be divided into 5 habitat types by using cluster analysis. According to coefficients variation analysis (CV), three primary conclusions can be drawn: (1) the metrics of Hilsenhoff Biotic Index (HBI), Percent Tolerant Taxa (PTT), Percent dominant taxon (PDT), and community loss index (CLI), based on macroinvertebrates, and the metrics of algal density (AD), the proportion of chlorophyta (CHL), and the proportion of cyanophyta (CYA), based on periphytons, were mostly constant throughout our study; (2) in terms of spatial variation, the CV values in the macroinvertebratebased metrics were lower than the CV values in the periphyton-based metrics, and these findings may be caused by the effects of changes in environmental factors; whereas, the CV values in the macroinvertebrate-based metrics were higher than those in the periphyton-based metrics, and these results may be linked to the influences of phenology and life history patterns of the macroinvertebrate individuals; and (3) the CV values for the functionalbased metrics were higher than those for the structuralbased metrics. Therefore, spatial and temporal variation for metrics should be considered when assessing applying the biometrics.
How will provider-focused payment reform impact geographic variation in Medicare spending?
Auerbach, David; Mehrotra, Ateev; Hussey, Peter; Huckfeldt, Peter J; Alpert, Abby; Lau, Christopher; Shier, Victoria
2015-06-01
The Institute of Medicine has recently argued against a value index as a mechanism to address geographic variation in spending and instead promoted payment reform targeted at individual providers. It is unknown whether such provider-focused payment reform reduces geographic variation in spending. We estimated the potential impact of 3 Medicare provider-focused payment policies-pay-for-performance, bundled payment, and accountable care organizations-on geographic variation in Medicare spending across Hospital Referral Regions (HRRs). We compared geographic variation in spending, measured using the coefficient of variation (CV) across HRRs, between the baseline case and a simulation of each of the 3 policies. Policy simulation based on 2008 national Medicare data combined with other publicly available data. Compared with the baseline (CV, 0.171), neither pay-for-performance nor accountable care organizations would change geographic variation in spending (CV, 0.171), while bundled payment would modestly reduce geographic variation (CV, 0.165). In our models, the bundled payment for inpatient and post acute care services in Medicare would modestly reduce geographic variation in spending, but neither accountable care organizations nor pay-for-performance appear to have an impact.
Seidu, Issaka; Zhekova, Hristina R; Seth, Michael; Ziegler, Tom
2012-03-08
The performance of the second-order spin-flip constricted variational density functional theory (SF-CV(2)-DFT) for the calculation of the exchange coupling constant (J) is assessed by application to a series of triply bridged Cu(II) dinuclear complexes. A comparison of the J values based on SF-CV(2)-DFT with those obtained by the broken symmetry (BS) DFT method and experiment is provided. It is demonstrated that our methodology constitutes a viable alternative to the BS-DFT method. The strong dependence of the calculated exchange coupling constants on the applied functionals is demonstrated. Both SF-CV(2)-DFT and BS-DFT affords the best agreement with experiment for hybrid functionals.
Valdez, Ernest W.; Bogan, Michael A.
2009-01-01
Few studies have investigated the relationship between morphological variation and local feeding habits of bats in the United States. We used discriminant function analysis (DFA) to compare cranial morphology of Myotis occultus from southern Colorado, and central, and southern New Mexico. We analyzed guano collected from maternity colonies in southern Colorado and central New Mexico to compare food habits. Bats from southern Colorado had the smallest values on the first canonical variate (CV1) that also reflected the smallest measurements of key cranial and dental variables, including height of coronoid process, width of molar, and dentary thickness. Bats from central and southern New Mexico had intermediate and large CV1 values, respectively. Overall, CV1 discriminated individuals occurring in southern Colorado and central New Mexico from those in southern New Mexico. CV2 served best at discriminating bats of southern Colorado from those of central New Mexico. Comparison of food habits revealed that individuals from southern Colorado ate more soft-bodied prey items (e.g., flies) whereas bats from central New Mexico ate more hard-bodied prey items (e.g., beetles). As shown in earlier studies that investigated relationships between morphology and diet of insectivorous bats, we found differences in skull morphology of M. occultusthat were correlated with differences in food habits.
Li, Tianhong; Ding, Yao
2017-01-01
The regional policy in China is shifting from solely gross domestic product (GDP) orientation to development that is more balanced between economic growth and ecological protection, as well as achieving equality among regions. Using land use maps and the adjusted value coefficients to assess ecosystem service values (ESV) for the 1980s, 1995, 2000, and 2010, we estimated the ESV in Shaanxi Province for different years, and characterized the spatial and temporal distribution of ESV and GDP. The results demonstrated that the total value of ecosystem services in Shaanxi Province increased from 208.95 billion Yuan in the 1980s to 309.76 billion Yuan in 2010. Variation Coefficient (Cv) and Theil index (T) were used to reflect the disparities of GDP or ESV within the study area. The values of Cv in descending order are GDP, ESV per capita, ESV, and GDP per capita. The Theil indexes of GDP were much greater than the ones of ESV. Variations of Cv and T showed that disparity in GDP kept increasing from the 1980s to 2000, then decreased; while no significant change in regional disparity of ESV were detected in parallel. The cities with higher GDP usually contributed little to ESV, and vice versa. The variation in GDP and ESV, in terms of the prefectural totals and per capita values, increased from the 1980s to 2010. This study provides an accessible way for local decision makers to evaluate the regional balance between economic growth and ecosystem services. PMID:28358918
Li, Tianhong; Ding, Yao
2017-01-01
The regional policy in China is shifting from solely gross domestic product (GDP) orientation to development that is more balanced between economic growth and ecological protection, as well as achieving equality among regions. Using land use maps and the adjusted value coefficients to assess ecosystem service values (ESV) for the 1980s, 1995, 2000, and 2010, we estimated the ESV in Shaanxi Province for different years, and characterized the spatial and temporal distribution of ESV and GDP. The results demonstrated that the total value of ecosystem services in Shaanxi Province increased from 208.95 billion Yuan in the 1980s to 309.76 billion Yuan in 2010. Variation Coefficient (Cv) and Theil index (T) were used to reflect the disparities of GDP or ESV within the study area. The values of Cv in descending order are GDP, ESV per capita, ESV, and GDP per capita. The Theil indexes of GDP were much greater than the ones of ESV. Variations of Cv and T showed that disparity in GDP kept increasing from the 1980s to 2000, then decreased; while no significant change in regional disparity of ESV were detected in parallel. The cities with higher GDP usually contributed little to ESV, and vice versa. The variation in GDP and ESV, in terms of the prefectural totals and per capita values, increased from the 1980s to 2010. This study provides an accessible way for local decision makers to evaluate the regional balance between economic growth and ecosystem services.
Zumárraga, Mercedes; González-Torres, Miguel A; Arrue, Aurora; Dávila, Ricardo; Dávila, Wendy; Inchausti, Lucía; Pérez-Cabeza, Lucía; Fernández-Rivas, Aránzazu; Bustamante, Sonia; Basterreche, Nieves; Guimón, José
2011-08-01
In the present study we have measured, on a monthly basis, the concentration of plasma homovanillic acid (pHVA) in schizophrenic patients during 13 months of their pharmacological treatment. The average pHVA values of each patient were within the range of 7.30-17.70 ng/ml and the coefficients of variation for each patient (CV %) were within the range of 13-33%. Half of the patients that showed higher pHVA CV% values also showed higher scores on the Brief Psychiatric Rating Scale at the beginning of the study, and improved more after 6 months, when compared to the remaining 50% with lower CV% values. There was no significant relationship between the scores of the Wisconsin Card Sort Test and the concentration or the CV% of the pHVA of each patient. A greater variability in the pHVA may be associated with a greater plasticity of the dopaminergic system and a better clinical response.
Characterizing the variation in pH measurements with apheresis platelets.
Moroff, Gary; Seetharaman, Shalini; Kurtz, James; Wagner, Stephen J
2011-11-01
pH measurements of platelet (PLT) components remain a key parameter when assessing how storage and shipping conditions influence the retention of PLT properties. Studies were conducted to characterize variations in pH measured with two pH meters and a blood gas analyzer. Samples were obtained from apheresis PLT units that were stored with or without continuous agitation to measure a range of pH values. pH values were determined with pH meters at room temperature (20-24°C) upon placing of samples in 5-mL sterile polypropylene tubes and with the blood gas analyzer at 37°C upon injection of identical samples, with conversion to 22°C. The calculated coefficient of variation (%CV) of pH measurements using pH meters (n = 10) was 0.43% or less. The %CV values were comparable with different samples having pH values ranging from 6.0 to 7.4. The %CV levels with the blood gas analyzer were comparable to those observed with the pH meters. The difference in the mean pH values for the two pH meters was no greater than 0.10 units, with 9 of 10 samples having differences in values of 0.05 or less; however, greater differences of values (0.1 to 0.2) were observed between pH measured using the blood gas analyzer and pH meters. Our data show good precision and comparability of pH measurements with two pH meters. Differences in pH values were greater on comparison of the blood gas analyzer with the pH meters. © 2011 American Association of Blood Banks.
NASA Astrophysics Data System (ADS)
Bender, Amanda L. D.; Chitwood, Daniel H.; Bradley, Alexander S.
2017-06-01
Leaf wax n-alkanes are broadly used to reconstruct paleoenvironmental information. However, the utility of n-alkanes as a paleoenvironmental proxy may be modulated by the extent to which biological as well as environmental factors influence the structural and isotopic variability of leaf waxes. In paleoclimate applications, there is usually an implicit assumption that most variation of leaf wax traits through a time series can be attributed to environmental change and that biological sources of variability within plant communities are small. For example, changes in hydrology affect the δ2H of waxes via rainwater and the δ13C of leaf waxes by changing plant communities. We measured the degree of genetic control over δ13C variation in leaf waxes within closely related species with an experimental greenhouse growth study. We measured the proportion of variability in structural and isotopic leaf wax traits that is attributable to genetic variation using a set of 76 introgression lines (ILs) between two interfertile Solanum (tomato) species: S. lycopersicum cv M82 (hereafter cv M82) and S. pennellii. Leaves of S. pennellii, a wild desert tomato relative, produced significantly more iso-alkanes than cv M82, a domesticated tomato cultivar adapted to water-replete conditions. We report a methylation index to summarize the ratio of branched (iso- and anteiso-) to total alkanes. Between S. pennellii and cv M82, the iso-alkanes were found to be enriched in 13C by 1.2-1.4‰ over n-alkanes. The broad-sense heritability values (H2) of leaf wax traits describe the degree to which genetic variation contributes to variation of these traits. Variation of individual carbon isotopic compositions of alkanes were of low heritability (H2 = 0.13-0.19), suggesting that most variation in δ13C of leaf waxes in this study can be attributed to environmental variance. This supports the interpretation that variation in the δ13C of wax compounds recorded in sediments reflects paleoenvironmental and vegetation changes. Average chain length (ACL) values of n-alkanes were of intermediate heritability (H2 = 0.30), suggesting that ACL values are more strongly influenced by genetic cues.
Measuring the glycemic index of foods: interlaboratory study.
Wolever, Thomas M S; Brand-Miller, Jennie C; Abernethy, John; Astrup, Arne; Atkinson, Fiona; Axelsen, Mette; Björck, Inger; Brighenti, Furio; Brown, Rachel; Brynes, Audrey; Casiraghi, M Cristina; Cazaubiel, Murielle; Dahlqvist, Linda; Delport, Elizabeth; Denyer, Gareth S; Erba, Daniela; Frost, Gary; Granfeldt, Yvonne; Hampton, Shelagh; Hart, Valerie A; Hätönen, Katja A; Henry, C Jeya; Hertzler, Steve; Hull, Sarah; Jerling, Johann; Johnston, Kelly L; Lightowler, Helen; Mann, Neil; Morgan, Linda; Panlasigui, Leonora N; Pelkman, Christine; Perry, Tracy; Pfeiffer, Andreas F H; Pieters, Marlien; Ramdath, D Dan; Ramsingh, Rayna T; Robert, S Daniel; Robinson, Carol; Sarkkinen, Essi; Scazzina, Francesca; Sison, Dave Clark D; Sloth, Birgitte; Staniforth, Jane; Tapola, Niina; Valsta, Liisa M; Verkooijen, Inge; Weickert, Martin O; Weseler, Antje R; Wilkie, Paul; Zhang, Jian
2008-01-01
Many laboratories offer glycemic index (GI) services. We assessed the performance of the method used to measure GI. The GI of cheese-puffs and fruit-leather (centrally provided) was measured in 28 laboratories (n=311 subjects) by using the FAO/WHO method. The laboratories reported the results of their calculations and sent the raw data for recalculation centrally. Values for the incremental area under the curve (AUC) reported by 54% of the laboratories differed from central calculations. Because of this and other differences in data analysis, 19% of reported food GI values differed by >5 units from those calculated centrally. GI values in individual subjects were unrelated to age, sex, ethnicity, body mass index, or AUC but were negatively related to within-individual variation (P=0.033) expressed as the CV of the AUC for repeated reference food tests (refCV). The between-laboratory GI values (mean+/-SD) for cheese-puffs and fruit-leather were 74.3+/-10.5 and 33.2+/-7.2, respectively. The mean laboratory GI was related to refCV (P=0.003) and the type of restrictions on alcohol consumption before the test (P=0.006, r2=0.509 for model). The within-laboratory SD of GI was related to refCV (P<0.001), the glucose analysis method (P=0.010), whether glucose measures were duplicated (P=0.008), and restrictions on dinner the night before (P=0.013, r2=0.810 for model). The between-laboratory SD of the GI values is approximately 9. Standardized data analysis and low within-subject variation (refCV<30%) are required for accuracy. The results suggest that common misconceptions exist about which factors do and do not need to be controlled to improve precision. Controlled studies and cost-benefit analyses are needed to optimize GI methodology. The trial was registered at clinicaltrials.gov as NCT00260858.
GPFA-AB_Phase1GeologicReservoirsContentModel10_26_2015.xls
Teresa E. Jordan
2015-09-30
This dataset conforms to the Tier 3 Content Model for Geologic Reservoirs Version 1.0. It contains the known hydrocarbon reservoirs within the study area of the GPFA-AB Phase 1 Task 2, Natural Reservoirs Quality Analysis (Project DE-EE0006726). The final values for Reservoir Productivity Index (RPI) and uncertainty (in terms of coefficient of variation, CV) are included. RPI is in units of liters per MegaPascal-second (L/MPa-s), quantified using permeability, thickness of formation, and depth. A higher RPI is more optimal. Coefficient of Variation (CV) is the ratio of the standard deviation to the mean RPI for each reservoir. A lower CV is more optimal. Details on these metrics can be found in the Reservoirs_Methodology_Memo.pdf uploaded to the Geothermal Data Repository Node of the NGDS in October of 2015.
Zhekova, Hristina R; Seth, Michael; Ziegler, Tom
2011-11-14
We have recently developed a methodology for the calculation of exchange coupling constants J in weakly interacting polynuclear metal clusters. The method is based on unrestricted and restricted second order spin-flip constricted variational density functional theory (SF-CV(2)-DFT) and is here applied to eight binuclear copper systems. Comparison of the SF-CV(2)-DFT results with experiment and with results obtained from other DFT and wave function based methods has been made. Restricted SF-CV(2)-DFT with the BH&HLYP functional yields consistently J values in excellent agreement with experiment. The results acquired from this scheme are comparable in quality to those obtained by accurate multi-reference wave function methodologies such as difference dedicated configuration interaction and the complete active space with second-order perturbation theory. © 2011 American Institute of Physics
The Spatial Variations and Hotspots of Ecosystem Service Values in India During 1985 - 2005
NASA Astrophysics Data System (ADS)
Sannigrahi, S.; Bhatt, S.; Paul, S. K.; Sen, S.; Rahmat, S.; Uniyal, B.
2017-12-01
Ecosystem services can be defined as the processes and functions of the natural ecosystem through which the basic needs and demands of human well-being are sustained and fulfilled. In this study, the spatiotemporal variation and clusters of ESV are analyzed during 1985 - 2005 using benefits transfer approach. The spatial heterogeneity of ESV was assessed through Local Morans I, Getis-Ord-Gi hotspot, and Geary's I statistics, respectively. The temporal uncertainty of ESV was estimated through Ecosystem Service Change Index (ESCI), Ecosystem Service Status Index (ESSI). The sensitivity of ESV to land use/land cover changes were estimated using the Coefficient of Elasticity (CE) approach. The variability of ESV in different land-use categories was examined through Coefficient of Variation (CV), Theil Index (TI), Ginni Coefficient and Entropy method. The contribution of ESV to GDP was quantified using the percent of ESV (%ESV) approach. Total eight ecoregions were considered for estimating the changing dynamics of high and low ESV clusters during 1985 - 2005. Among the eight ecoregions, grassland shows the minimum CV of ESV (1.15) during 1985 - 2005, indicating the most stable and undisturbed eco-regions in India during this study period, followed by cropland (CV= 2.0), forest land (2.32), water bodies (3.27), mangrove (3.5) respectively. While, the urban built-up (CV = 15.89) and wetland (CV = 10.91) exhibits the highest CV during 1985 - 2005. The ESCI was found highly negative (-0.05) over forested region, and negative (-0.02) for water bodies, while a very highly positive (0.38), highly positive (0.24), moderate positive (0.06), weakly positive (0.03) and very weak positive (0.02) values have quantified for urban built-up, wetland, mangrove, cropland and, grassland, respectively. The overall ESSI was very good for urban built-up categories (0.24), followed by wetland (0.15), mangrove (0.04), cropland (0.02) and, grassland (0.01), respectively. During this period (1985 - 2005), the changes of ESV were found statistically significant for urban built-up (t = 10.90, P = 0.008), and wetland (t = 15.88, P = 0.004), while the changes were insignificant for rest of the ecoregions.
Koga, Masafumi; Murai, Jun; Morita, Shinya; Saito, Hiroshi; Kasayama, Soji
2013-01-01
It has been suggested that plasma glucose (PG) levels per se and long-term variations in PG levels are associated with diabetic vascular complications. Glycated albumin (GA) reflects shorter-term glycemic control, as well as postprandial PG levels, as compared to HbA1c. In this study, we hypothesized that GA more strongly reflects long-term variations in PG levels than HbA1c, and compared the variability of HbA1c and that of GA in patients with type 1 diabetes mellitus (T1DM) and type 2 diabetes mellitus (T2DM). This study included 8 T1DM patients and 48 T2DM patients. Over a 1-year period, HbA1c and GA were measured every month and the mean values and coefficients of variation (CV) for each patient were calculated. In both T1DM and T2DM patients, the CV of GA was significantly higher than the CV of HbA1c. Both the CV of HbA1c and the CV of GA were significantly higher in the T1DM patients than in the T2DM patients. The annual variability in GA was greater than that in HbA1c. In addition, the annual variability in HbA1c and that in GA in the T1DM patients were greater than in the T2DM patients. Our findings suggest that GA more accurately reflects long-term variations in PG levels than HbA1c. Copyright © 2013 Elsevier Inc. All rights reserved.
Haeckel, Rainer; Wosniok, Werner
2010-10-01
The distribution of many quantities in laboratory medicine are considered to be Gaussian if they are symmetric, although, theoretically, a Gaussian distribution is not plausible for quantities that can attain only non-negative values. If a distribution is skewed, further specification of the type is required, which may be difficult to provide. Skewed (non-Gaussian) distributions found in clinical chemistry usually show only moderately large positive skewness (e.g., log-normal- and χ(2) distribution). The degree of skewness depends on the magnitude of the empirical biological variation (CV(e)), as demonstrated using the log-normal distribution. A Gaussian distribution with a small CV(e) (e.g., for plasma sodium) is very similar to a log-normal distribution with the same CV(e). In contrast, a relatively large CV(e) (e.g., plasma aspartate aminotransferase) leads to distinct differences between a Gaussian and a log-normal distribution. If the type of an empirical distribution is unknown, it is proposed that a log-normal distribution be assumed in such cases. This avoids distributional assumptions that are not plausible and does not contradict the observation that distributions with small biological variation look very similar to a Gaussian distribution.
Using basic statistics on the individual patient's own numeric data.
Hart, John
2012-12-01
This theoretical report gives an example for how coefficient of variation (CV) and quartile analysis (QA) to assess outliers might be able to be used to analyze numeric data in practice for an individual patient. A patient was examined for 8 visits using infrared instrumentation for measurement of mastoid fossa temperature differential (MFTD) readings. The CV and QA were applied to the readings. The participant also completed the Short Form-12 health perception survey on each visit, and these findings were correlated with CV to determine if CV had outcomes support (clinical significance). An outlier MFTD reading was observed on the eighth visit according to QA that coincided with the largest CV value for the MFTDs. Correlations between the Short Form-12 and CV were low to negligible, positive, and statistically nonsignificant. This case provides an example of how basic statistical analyses could possibly be applied to numerical data in chiropractic practice for an individual patient. This might add objectivity to analyzing an individual patient's data in practice, particularly if clinical significance of a clinical numerical finding is unknown.
Park, Sang Hyuk; Park, Chan-Jeoung; Kim, Mi-Jeong; Choi, Mi-Ok; Han, Min-Young; Cho, Young-Uk; Jang, Seongsoo
2014-12-01
We developed and validated an interinstrument comparison method for automatic hematology analyzers based on the 99th percentile coefficient of variation (CV) cutoff of daily means and validated in both patient samples and quality control (QC) materials. A total of 120 patient samples were obtained over 6 months. Data from the first 3 months were used to determine 99th percentile CV cutoff values, and data obtained in the last 3 months were used to calculate acceptable ranges and rejection rates. Identical analyses were also performed using QC materials. Two instrument comparisons were also performed, and the most appropriate allowable total error (ATE) values were determined. The rejection rates based on the 99th percentile cutoff values were within 10.00% and 9.30% for the patient samples and QC materials, respectively. The acceptable ranges of QC materials based on the currently used method were wider than those calculated from the 99th percentile CV cutoff values in most items. In two-instrument comparisons, 34.8% of all comparisons failed, and 87.0% of failed comparisons were successful when 4 SD was applied as an ATE value instead of 3 SD. The 99th percentile CV cutoff value-derived daily acceptable ranges can be used as a real-time interinstrument comparison method in both patient samples and QC materials. Applying 4 SD as an ATE value can significantly reduce unnecessarily followed recalibration in the leukocyte differential counts, reticulocytes, and mean corpuscular volume. Copyright© by the American Society for Clinical Pathology.
High-Throughput RNA Interference Screening: Tricks of the Trade
Nebane, N. Miranda; Coric, Tatjana; Whig, Kanupriya; McKellip, Sara; Woods, LaKeisha; Sosa, Melinda; Sheppard, Russell; Rasmussen, Lynn; Bjornsti, Mary-Ann; White, E. Lucile
2016-01-01
The process of validating an assay for high-throughput screening (HTS) involves identifying sources of variability and developing procedures that minimize the variability at each step in the protocol. The goal is to produce a robust and reproducible assay with good metrics. In all good cell-based assays, this means coefficient of variation (CV) values of less than 10% and a signal window of fivefold or greater. HTS assays are usually evaluated using Z′ factor, which incorporates both standard deviation and signal window. A Z′ factor value of 0.5 or higher is acceptable for HTS. We used a standard HTS validation procedure in developing small interfering RNA (siRNA) screening technology at the HTS center at Southern Research. Initially, our assay performance was similar to published screens, with CV values greater than 10% and Z′ factor values of 0.51 ± 0.16 (average ± standard deviation). After optimizing the siRNA assay, we got CV values averaging 7.2% and a robust Z′ factor value of 0.78 ± 0.06 (average ± standard deviation). We present an overview of the problems encountered in developing this whole-genome siRNA screening program at Southern Research and how equipment optimization led to improved data quality. PMID:23616418
Changes in gait while backward counting in demented older adults with frontal lobe dysfunction.
Allali, Gilles; Kressig, Reto W; Assal, Frédéric; Herrmann, François R; Dubost, Véronique; Beauchet, Olivier
2007-10-01
Gait disorders caused by dementia have been associated with frontal lobe dysfunction. Dual-tasking is used to explore the involvement of cortical level in gait control. It has been shown that dual-task induced gait changes that could be related to (1) the efficiency of executive function, (2) the level of difficulty involved in the walking-associated task, or (3) the articulo-motor components comprised in the walking-associated task. A better understanding of dual-task related changes in demented subjects with frontal lobe dysfunction could help us to clarify the role of the frontal lobe in motor gait control. To assess and compare the effects of two mental arithmetic tasks involving similar articulo-motor components but different level of difficulty on the mean values and coefficient of variation (CV) of stride time among demented older adults with impaired executive function. The mean values and coefficients of variation of stride time were measured using a GAITRite-System among 16 demented older adults with impaired executive function while walking with and without forward counting (FC) and backward counting (BC). The mean values and CV of stride time were significantly higher under both dual-task conditions than during a simple walking task (p<0.05). The change in CV of stride time during BC was significantly higher when compared with the change during FC (p=0.015), whereas the change in mean value was not significant (p=0.056). There was no difference between the dual-task and single task condition as far the number of enumerated figures were concerned (p=0.678 for FC and p=0.069 for BC), but significantly fewer figures were enumerated while BC compared with FC (p<0.001). BC provoked more changes in gait parameters than FC with major modification in gait variability related to an inappropriate focusing of attention. These findings suggest that the CV may be a suitable criterion for the assessment of gait control.
Psychosocial determinants of premature cardiovascular mortality differences within Hungary.
Kopp, Maria; Skrabski, Arpád; Szántó, Zsuzsa; Siegrist, Johannes
2006-09-01
The life expectancy gap between Central-Eastern European (CEE) countries, including Hungary, and Western Europe (WE) is mainly attributable to excess cardiovascular (CV) mortality in midlife. This study explores the contribution of socioeconomic, work related, psychosocial, and behavioural variables to explaining variations of middle aged male and female CV mortality across 150 sub-regions in Hungary. Cross sectional, ecological analyses. 150 sub-regions of Hungary. 12 643 people were interviewed in Hungarostudy 2002 survey, representing the Hungarian population according to sex, age, and sub-regions. Independent variables were income, education, control in work, job insecurity, weekend working hours, social support, depression, hostility, anomie, smoking, body mass index, and alcohol misuse. Gender specific standardised premature (45-64 years) total CV, ischaemic heart disease, and cerebrovascular mortality rates in 150 sub-regions of Hungary. Low education and income were the most important determinants of mid-aged CV mortality differences across sub-regions. High weekend workload, low social support at work, and low control at work account for a large part of variation in male premature CV mortality rates, whereas job insecurity, high weekend workload, and low control at work contribute most noticeably to variations in premature CV mortality rates among women. Low social support from friends, depression, anomie, hostility, alcohol misuse and cigarette smoking can also explain a considerable part of variations of premature CV mortality differences. Variations in middle aged CV mortality rates in a rapidly changing society in CEE are largely accounted for by distinct unfavourable working and other psychosocial stress conditions.
Variability of breathing during wakefulness while using CPAP predicts adherence.
Fujita, Yukio; Yamauchi, Motoo; Uyama, Hiroki; Kumamoto, Makiko; Koyama, Noriko; Yoshikawa, Masanori; Strohl, Kingman P; Kimura, Hiroshi
2017-02-01
The standard therapy for obstructive sleep apnoea (OSA) is continuous positive airway pressure (CPAP) therapy. However, long-term adherence remains at ~50% despite improvements in behavioural and educational interventions. Based on prior work, we explored whether regularity of breathing during wakefulness might be a physiologic predictor of CPAP adherence. Of the 117 consecutive patients who were diagnosed with OSA and prescribed CPAP, 79 CPAP naïve patients were enrolled in this prospective study. During CPAP initiation, respiratory signals were collected using respiratory inductance plethysmography while wearing CPAP during wakefulness in a seated position. Breathing regularity was assessed by the coefficient of variation (CV) for breath-by-breath estimated tidal volume (V T ) and total duration of respiratory cycle (Ttot). In a derivation group (n = 36), we determined the cut-off CV value which predicted poor CPAP adherence at the first month of therapy, and verified the validity of this predetermined cut-off value in the remaining participants (validation group; n = 43). In the derivation group, the CV for estimated V T was significantly higher in patients with poor adherence than with good adherence (median (interquartile range): 44.2 (33.4-57.4) vs 26.0 (20.4-33.2), P < 0.001). The CV cut-off value for estimated V T for poor CPAP adherence was 34.0, according to a receiver-operating characteristic (ROC) curve. In the validation group, the CV value for estimated V T >34.0 confirmed to be predicting poor CPAP adherence (sensitivity, 0.78; specificity, 0.83). At the initiation of therapy, breathing regularity during wakefulness while wearing CPAP is an objective predictor of short-term CPAP adherence. © 2016 Asian Pacific Society of Respirology.
A proof for Rhiel's range estimator of the coefficient of variation for skewed distributions.
Rhiel, G Steven
2007-02-01
In this research study is proof that the coefficient of variation (CV(high-low)) calculated from the highest and lowest values in a set of data is applicable to specific skewed distributions with varying means and standard deviations. Earlier Rhiel provided values for d(n), the standardized mean range, and a(n), an adjustment for bias in the range estimator of micro. These values are used in estimating the coefficient of variation from the range for skewed distributions. The d(n) and an values were specified for specific skewed distributions with a fixed mean and standard deviation. In this proof it is shown that the d(n) and an values are applicable for the specific skewed distributions when the mean and standard deviation can take on differing values. This will give the researcher confidence in using this statistic for skewed distributions regardless of the mean and standard deviation.
Grillo, Andrea; Parati, Gianfranco; Rovina, Matteo; Moretti, Francesco; Salvi, Lucia; Gao, Lan; Baldi, Corrado; Sorropago, Giovanni; Faini, Andrea; Millasseau, Sandrine C; Scalise, Filippo; Carretta, Renzo; Salvi, Paolo
2017-12-08
Aortic pulse wave velocity (PWV) is an indirect index of arterial stiffness and an independent cardiovascular risk factor. Consistency of PWV assessment over time is thus an essential feature for its clinical application. However, studies providing a comparative estimate of the reproducibility of PWV across different noninvasive devices are lacking, especially in the elderly and in individuals at high cardiovascular risk. Aimed at filling this gap, short-term repeatability of PWV, estimated with 6 different devices (Complior Analyse, PulsePen-ETT, PulsePen-ET, SphygmoCor Px/Vx, BPLab, and Mobil-O-Graph), was evaluated in 102 high cardiovascular risk patients hospitalized for suspected coronary artery disease (72 males, 65 ± 13 years). PWV was measured in a single session twice, at 15-minute interval, and its reproducibility was assessed though coefficient of variation (CV), coefficient of repeatability, and intraclass correlation coefficient. The CV of PWV, measured with any of these devices, was <10%. Repeatability was higher with cuff-based methods (BPLab: CV = 5.5% and Mobil-O-Graph: CV = 3.4%) than with devices measuring carotid-femoral PWV (Complior: CV = 8.2%; PulsePen-TT: CV = 8.0%; PulsePen-ETT: CV = 5.8%; and SphygmoCor: CV = 9.5%). In the latter group, PWV repeatability was lower in subjects with higher carotid-femoral PWV. The differences in PWV between repeated measurements, except for the Mobil-O-Graph, did not depend on short-term variations of mean blood pressure or heart rate. Our study shows that the short-term repeatability of PWV measures is good but not homogenous across different devices and at different PWV values. These findings, obtained in patients at high cardiovascular risk, may be relevant when evaluating the prognostic importance of PWV. © American Journal of Hypertension, Ltd 2017. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Polymorphisms in TRPV1 and TAS2Rs associate with sensations from sampled ethanol
Allen, Alissa L.; McGeary, John E.; Hayes, John E.
2014-01-01
Background Genetic variation in chemosensory genes can explain variability in individual’s perception of and preference for many foods and beverages. To gain insight into variable preference and intake of alcoholic beverages, we explored individual variability in the responses to sampled ethanol. In humans, ethanol elicits sweet, bitter and burning sensations. Here, we explore the relationship between variation in ethanol sensations and polymorphisms in genes encoding bitter taste receptors (TAS2Rs) and a polymodal nociceptor (TRPV1). Methods Caucasian participants (n=93) were genotyped for 16 SNPs in TRPV1, 3 SNPs in TAS2R38 and 1 SNP in TAS2R13. Participants rated sampled ethanol on a generalized Labeled Magnitude Scale. Two stimuli were presented: a 16% ethanol whole mouth sip-and-spit solution with a single time-point rating of overall intensity, and a cotton swab saturated with 50% ethanol on the circumvallate papillae (CV) with repeated ratings made over 3 minutes. Area under the curve (AUC) was calculated for the time-intensity data. Results The ethanol whole mouth solution had overall intensity ratings near ‘very strong’. Burning/stinging had the highest mean AUC values, followed by bitterness and sweetness. Whole mouth intensity ratings were significantly associated with burning/stinging and bitterness AUC values on the CV. Three TRPV1 SNPs (rs224547, rs4780521, rs161364) were associated with ethanol sensations on the CV, with two (rs224547 and rs4780521) exhibiting strong linkage disequilibrium. Additionally, the TAS2R38 SNPs rs713598, rs1726866, and rs10246939 formed a haplotype, and were associated with bitterness on the CV. Lastly, overall intensity for whole mouth ethanol associated with the TAS2R13 SNP rs1015443. Conclusions These data suggest genetic variations in TRPV1 and TAS2Rs influence sensations from sampled ethanol and may potentially influence how individuals initially respond to alcoholic beverages. PMID:25257701
Stochastic approach to the derivation of emission limits for wastewater treatment plants.
Stransky, D; Kabelkova, I; Bares, V
2009-01-01
Stochastic approach to the derivation of WWTP emission limits meeting probabilistically defined environmental quality standards (EQS) is presented. The stochastic model is based on the mixing equation with input data defined by probability density distributions and solved by Monte Carlo simulations. The approach was tested on a study catchment for total phosphorus (P(tot)). The model assumes input variables independency which was proved for the dry-weather situation. Discharges and P(tot) concentrations both in the study creek and WWTP effluent follow log-normal probability distribution. Variation coefficients of P(tot) concentrations differ considerably along the stream (c(v)=0.415-0.884). The selected value of the variation coefficient (c(v)=0.420) affects the derived mean value (C(mean)=0.13 mg/l) of the P(tot) EQS (C(90)=0.2 mg/l). Even after supposed improvement of water quality upstream of the WWTP to the level of the P(tot) EQS, the WWTP emission limits calculated would be lower than the values of the best available technology (BAT). Thus, minimum dilution ratios for the meaningful application of the combined approach to the derivation of P(tot) emission limits for Czech streams are discussed.
Evaluation of two methods for using MR information in PET reconstruction
NASA Astrophysics Data System (ADS)
Caldeira, L.; Scheins, J.; Almeida, P.; Herzog, H.
2013-02-01
Using magnetic resonance (MR) information in maximum a posteriori (MAP) algorithms for positron emission tomography (PET) image reconstruction has been investigated in the last years. Recently, three methods to introduce this information have been evaluated and the Bowsher prior was considered the best. Its main advantage is that it does not require image segmentation. Another method that has been widely used for incorporating MR information is using boundaries obtained by segmentation. This method has also shown improvements in image quality. In this paper, two methods for incorporating MR information in PET reconstruction are compared. After a Bayes parameter optimization, the reconstructed images were compared using the mean squared error (MSE) and the coefficient of variation (CV). MSE values are 3% lower in Bowsher than using boundaries. CV values are 10% lower in Bowsher than using boundaries. Both methods performed better than using no prior, that is, maximum likelihood expectation maximization (MLEM) or MAP without anatomic information in terms of MSE and CV. Concluding, incorporating MR information using the Bowsher prior gives better results in terms of MSE and CV than boundaries. MAP algorithms showed again to be effective in noise reduction and convergence, specially when MR information is incorporated. The robustness of the priors in respect to noise and inhomogeneities in the MR image has however still to be performed.
Luo, Ji; Chen, Youchao; Wu, Yanhong; Shi, Peili; She, Jia; Zhou, Peng
2012-01-01
Soil respiration (SR) is an important process in the global carbon cycle. It is difficult to estimate SR emission accurately because of its temporal and spatial variability. Primary forest succession on Glacier forehead provides the ideal environment for examining the temporal-spatial variation and controlling factors of SR. However, relevant studies on SR are relatively scarce, and variations, as well as controlling factors, remain uncertain in this kind of region. In this study, we used a static chamber system to measure SR in six sites which represent different stages of forest succession on forehead of a temperate glacier in Gongga Mountain, China. Our results showed that there was substantial temporal (coefficient of variation (CV) ranged from 39.3% to 73.9%) and spatial (CV ranged from 12.3% to 88.6%) variation in SR. Soil temperature (ST) at 5 cm depth was the major controlling factor of temporal variation in all six sites. Spatial variation in SR was mainly caused by differences in plant biomass and Total N among the six sites. Moreover, soil moisture (SM), microbial biomass carbon (MBC), soil organic carbon (SOC), pH and bulk density could influence SR by directly or indirectly affecting plant biomass and Total N. Q10 values (ranged from 2.1 to 4.7) increased along the forest succession, and the mean value (3.3) was larger than that of temperate ecosystems, which indicated a general tendency towards higher-Q10 in colder ecosystems than in warmer ecosystems. Our findings provided valuable information for understanding temporal-spatial variation and controlling factors of SR. PMID:22879950
Sign Language Translator Application Using OpenCV
NASA Astrophysics Data System (ADS)
Triyono, L.; Pratisto, E. H.; Bawono, S. A. T.; Purnomo, F. A.; Yudhanto, Y.; Raharjo, B.
2018-03-01
This research focuses on the development of sign language translator application using OpenCV Android based, this application is based on the difference in color. The author also utilizes Support Machine Learning to predict the label. Results of the research showed that the coordinates of the fingertip search methods can be used to recognize a hand gesture to the conditions contained open arms while to figure gesture with the hand clenched using search methods Hu Moments value. Fingertip methods more resilient in gesture recognition with a higher success rate is 95% on the distance variation is 35 cm and 55 cm and variations of light intensity of approximately 90 lux and 100 lux and light green background plain condition compared with the Hu Moments method with the same parameters and the percentage of success of 40%. While the background of outdoor environment applications still can not be used with a success rate of only 6 managed and the rest failed.
The match-to-match variation of match-running in elite female soccer.
Trewin, Joshua; Meylan, César; Varley, Matthew C; Cronin, John
2018-02-01
The purpose of this study was to examine the match-to-match variation of match-running in elite female soccer players utilising GPS, using full-match and rolling period analyses. Longitudinal study. Elite female soccer players (n=45) from the same national team were observed during 55 international fixtures across 5 years (2012-2016). Data was analysed using a custom built MS Excel spreadsheet as full-matches and using a rolling 5-min analysis period, for all players who played 90-min matches (files=172). Variation was examined using co-efficient of variation and 90% confidence limits, calculated following log transformation. Total distance per minute exhibited the smallest variation when both the full-match and peak 5-min running periods were examined (CV=6.8-7.2%). Sprint-efforts were the most variable during a full-match (CV=53%), whilst high-speed running per minute exhibited the greatest variation in the post-peak 5-min period (CV=143%). Peak running periods were observed as slightly more variable than full-match analyses, with the post-peak period very-highly variable. Variability of accelerations (CV=17%) and Player Load (CV=14%) was lower than that of high-speed actions. Positional differences were also present, with centre backs exhibiting the greatest variation in high-speed movements (CV=41-65%). Practitioners and researchers should account for within player variability when examining match performances. Identification of peak running periods should be used to assist worst case scenarios. Whilst micro-sensor technology should be further examined as to its viable use within match-analyses. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Global sensitivity analysis of groundwater transport
NASA Astrophysics Data System (ADS)
Cvetkovic, V.; Soltani, S.; Vigouroux, G.
2015-12-01
In this work we address the model and parametric sensitivity of groundwater transport using the Lagrangian-Stochastic Advection-Reaction (LaSAR) methodology. The 'attenuation index' is used as a relevant and convenient measure of the coupled transport mechanisms. The coefficients of variation (CV) for seven uncertain parameters are assumed to be between 0.25 and 3.5, the highest value being for the lower bound of the mass transfer coefficient k0 . In almost all cases, the uncertainties in the macro-dispersion (CV = 0.35) and in the mass transfer rate k0 (CV = 3.5) are most significant. The global sensitivity analysis using Sobol and derivative-based indices yield consistent rankings on the significance of different models and/or parameter ranges. The results presented here are generic however the proposed methodology can be easily adapted to specific conditions where uncertainty ranges in models and/or parameters can be estimated from field and/or laboratory measurements.
Performance of electrolyte measurements assessed by a trueness verification program.
Ge, Menglei; Zhao, Haijian; Yan, Ying; Zhang, Tianjiao; Zeng, Jie; Zhou, Weiyan; Wang, Yufei; Meng, Qinghui; Zhang, Chuanbao
2016-08-01
In this study, we analyzed frozen sera with known commutabilities for standardization of serum electrolyte measurements in China. Fresh frozen sera were sent to 187 clinical laboratories in China for measurement of four electrolytes (sodium, potassium, calcium, and magnesium). Target values were assigned by two reference laboratories. Precision (CV), trueness (bias), and accuracy [total error (TEa)] were used to evaluate measurement performance, and the tolerance limit derived from the biological variation was used as the evaluation criterion. About half of the laboratories used a homogeneous system (same manufacturer for instrument, reagent and calibrator) for calcium and magnesium measurement, and more than 80% of laboratories used a homogeneous system for sodium and potassium measurement. More laboratories met the tolerance limit of imprecision (coefficient of variation [CVa]) than the tolerance limits of trueness (biasa) and TEa. For sodium, calcium, and magnesium, the minimal performance criterion derived from biological variation was used, and the pass rates for total error were approximately equal to the bias (<50%). For potassium, the pass rates for CV and TE were more than 90%. Compared with the non homogeneous system, the homogeneous system was superior for all three quality specifications. The use of commutable proficiency testing/external quality assessment (PT/EQA) samples with values assigned by reference methods can monitor performance and provide reliable data for improving the performance of laboratory electrolyte measurement. The homogeneous systems were superior to the non homogeneous systems, whereas accuracy of assigned values of calibrators and assay stability remained challenges.
Test-retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects.
Cutajar, Marica; Clayden, Jonathan D; Clark, Christopher A; Gordon, Isky
2011-12-01
This study assessed test-retest reliability and repeatability of diffusion tensor imaging (DTI) in the kidneys. Seven healthy volunteers (age range, 19-31 years), were imaged three consecutive times on the same day (short-term reliability) and the same imaging protocol was repeated after a month (long-term reliability). Diffusion-weighted magnetic resonance imaging scans in the coronal-oblique projection of the kidney were acquired on a 1.5 T scanner using a multi-section echo-planar sequence; six contiguous slices each 5 mm thick, diffusion sensitisation along 20 non-collinear directions, TR=730 ms, TE=73 ms and 2 b-values (0 and 400 s mm(-2)). Volunteers were asked to hold their breath throughout each data acquisition (approx. 20 s). The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were obtained from maps generated using dedicated software MIStar (Apollo Medical Imaging, Melbourne, Australia). Statistical analyses of both short- and long-term repeats were carried out from which the within-subject coefficient of variation (wsCV) was calculated. The wsCV obtained for both the ADC and FA values were less than 10% in all the analyses carried out. In addition, paired (repeated measures) t-test was used to measure the variation between the diffusion parameters collected from the two scanning sessions a month apart. It showed no significant difference and the wsCV obtained after comparing the first and second scans were found to be smaller than 15% for both ADC and FA. Renal DTI produces reliable and repeatable results which make longitudinal investigation of patients viable. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Polymorphisms in TRPV1 and TAS2Rs associate with sensations from sampled ethanol.
Allen, Alissa L; McGeary, John E; Hayes, John E
2014-10-01
Genetic variation in chemosensory genes can explain variability in individual's perception of and preference for many foods and beverages. To gain insight into variable preference and intake of alcoholic beverages, we explored individual variability in the responses to sampled ethanol (EtOH). In humans, EtOH elicits sweet, bitter, and burning sensations. Here, we explore the relationship between variation in EtOH sensations and polymorphisms in genes encoding bitter taste receptors (TAS2Rs) and a polymodal nociceptor (TRPV1). Caucasian participants (n = 93) were genotyped for 16 single nucleotide polymorphisms (SNPs) in TRPV1, 3 SNPs in TAS2R38, and 1 SNP in TAS2R13. Participants rated sampled EtOH on a generalized Labeled Magnitude Scale. Two stimuli were presented: a 16% EtOH whole-mouth sip-and-spit solution with a single time-point rating of overall intensity and a cotton swab saturated with 50% EtOH on the circumvallate papillae (CV) with ratings of multiple qualities over 3 minutes. Area-under-the-curve (AUC) was calculated for the time-intensity data. The EtOH whole-mouth solution had overall intensity ratings near "very strong." Burning/stinging had the highest mean AUC values, followed by bitterness and sweetness. Whole-mouth intensity ratings were significantly associated with burning/stinging and bitterness AUC values on the CV. Three TRPV1 SNPs (rs224547, rs4780521, rs161364) were associated with EtOH sensations on the CV, with 2 (rs224547 and rs4780521) exhibiting strong linkage disequilibrium. Additionally, the TAS2R38 SNPs rs713598, rs1726866, and rs10246939 formed a haplotype, and were associated with bitterness on the CV. Last, overall intensity for whole-mouth EtOH associated with the TAS2R13 SNP rs1015443. These data suggest genetic variation in TRPV1 and TAS2Rs influence sensations from sampled EtOH and may potentially influence how individuals initially respond to alcoholic beverages. Copyright © 2014 by the Research Society on Alcoholism.
Lippi, Giuseppe; Buonocore, Ruggero; Picanza, Alessandra; Schirosa, Fabio; Cervellin, Gianfranco
2016-01-01
Red blood cell distribution width (RDW) is significantly associated with a variety of human disorders. This study aimed to investigate whether RDW value at admission may predict the need of hospitalisation in patients presenting to the emergency department (ED) with acute allergic reactions. The study population consisted of adult patients (aged > 17) admitted to the ED for acute allergic reactions. One hundred and thirty-two subjects were included, 12 of whom (9%) required hospital admission for severity of symptoms. Patients who needed hospital admission displayed significantly lower values of haemoglobin and significantly higher values of RDW-coefficient of variation (RDW-CV). In multivariate analysis, haemoglobin and RDW-CV were found to be independent predictors of hospital admission. The area under the curve (AUC), sensitivity and specificity for predicting hospital admission were 0.72, 0.88 and 0.42 for haemoglobin and 0.73, 0.88 and 0.50 for RDW-CV, respectively. The combination of these tests (both positive) was characterised by 0.76 AUC, 0.83 sensitivity, 0.67 specificity, 0.96 negative predictive value and 0.30 positive predictive. The results of this study suggest that two common and inexpensive parameters such as haemoglobin and RDW are independent predictors of hospital admission in patients presenting to the ED with acute allergic reactions.
Changes in the cornea related to sickle cell disease: a pilot investigation.
Coşkun, Mesut; İlhan, Özgür; İlhan, Nilüfer; Tuzcu, Esra Ayhan; Daglioğlu, Mutlu Cihan; Kahraman, Hilal; Elbeyli, Ahmet; Yarbağ, Abdulhekim; Helvaci, Mehmet Rami
2015-01-01
To investigate corneal structural changes (central corneal thickness, endothelial cell count, and cellular morphology) in patients with sickle cell disease (SCD). This prospective study included 56 patients with SCD and 50 age- and sex-matched healthy subjects without any eye disease aside from refractive errors. Endothelial cell density (ECD), percentage of hexagonality, and the coefficient of variation in cell size (CV) were measured using noncontact specular microscopy, and central corneal thickness (CCT) was measured by pachymetry. The mean CCT value was 509.6 ± 20.7 μm in the study group and 520.8 ± 23.6 μm in the control group. The mean ECD, CV, and percentage of hexagonality values in the study group were 2712 ± 335 cells/mm², 34.5 ± 5.3%, and 57.2 ± 6.6%, respectively, and 3030 ± 247 cells/mm², 31.6 ± 5.0%, and 60.4 ± 6.9% in the control group, respectively. Endothelial cell density (p = 0.001), CCT (p = 0.011), CV (p = 0.005), and percentage of hexagonality values (p = 0.018) were significantly different between the study and control groups. The results of the current study indicate that patients with SCD had considerable morphologic changes in the structure of the cornea when compared to healthy subjects.
Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Gabriël, Sarah
2016-08-30
The monoclonal antibody-based circulating antigen detecting ELISA (B158/B60 Ag-ELISA) has been used elaborately in several studies for the diagnosis of human, bovine and porcine cysticercosis. Interpretation of test results requires a good knowledge of the test characteristics, including the repeatability and the effect of the borders of the ELISA plates. Repeatability was tested for 4 antigen-negative and 5 antigen-positive reference bovine serum samples by calculating the Percentage Coefficient of Variation (%CV) within and between plates, within and between runs, overall, for two batches of monoclonal antibodies and by 2 laboratory technicians. All CV values obtained were below 20% (except one: 24.45%), which indicates a good repeatability and a negligible technician error. The value of 24.45% for indicating the variability between batches of monoclonal antibodies for one positive sample is still acceptable for repeatability measures. Border effects were determined by calculating the %CV values between the inner and outer wells of one plate for 2 positive serum samples. Variability is a little more present in the outer wells but this effect is very small and no significant border effect was found. Copyright © 2016 Elsevier B.V. All rights reserved.
Variation of gene expression in Bacillus subtilis samples of fermentation replicates.
Zhou, Ying; Yu, Wen-Bang; Ye, Bang-Ce
2011-06-01
The application of comprehensive gene expression profiling technologies to compare wild and mutated microorganism samples or to assess molecular differences between various treatments has been widely used. However, little is known about the normal variation of gene expression in microorganisms. In this study, an Agilent customized microarray representing 4,106 genes was used to quantify transcript levels of five-repeated flasks to assess normal variation in Bacillus subtilis gene expression. CV analysis and analysis of variance were employed to investigate the normal variance of genes and the components of variance, respectively. The results showed that above 80% of the total variation was caused by biological variance. For the 12 replicates, 451 of 4,106 genes exhibited variance with CV values over 10%. The functional category enrichment analysis demonstrated that these variable genes were mainly involved in cell type differentiation, cell type localization, cell cycle and DNA processing, and spore or cyst coat. Using power analysis, the minimal biological replicate number for a B. subtilis microarray experiment was determined to be six. The results contribute to the definition of the baseline level of variability in B. subtilis gene expression and emphasize the importance of replicate microarray experiments.
Phenotypic Intratumoral Heterogeneity of Endometrial Carcinomas.
Silva, Cátia; Pires-Luís, Ana S; Rocha, Eduardo; Bartosch, Carla; Lopes, José M
2018-03-01
Intratumoral heterogeneity has been shown to play an important role in diagnostic accuracy, development of treatment resistance, and prognosis of cancer patients. Recent studies have proposed quantitative measurement of phenotypic intratumoral heterogeneity, but no study is yet available in endometrial carcinomas. In our study we evaluated the phenotypic intratumoral heterogeneity of a consecutive series of 10 endometrial carcinomas using measures of dispersion and diversity. Morphometric architectural (%tumor cells, %solid tumor, %differentiated tumor, and %lumens) and nuclear [volume-weighted mean nuclear volume ((Equation is included in full-text article.))] parameters, as well as estrogen receptor, progesterone receptor, p53, vimentin, and beta-catenin immunoexpression (H-score) were digitally analyzed in 20 microscopic fields per carcinoma. Quantitative measures of intratumoral heterogeneity included coefficient of variation (CV) and relative quadratic entropy (rQE). In each endometrial carcinoma there was slight variation of architecture from field to field, resulting in globally low levels of heterogeneity measures (mean CV %tumor cells: 0.10, %solid tumor: 0.73, %differentiated tumor: 0.19, %lumens: 0.61 and mean rQE %tumor cells: 18.5, %solid tumor: 20.3, %differentiated tumor: 25.6, %lumens: 21.8). Nuclear intratumoral heterogeneity was also globally low (mean (Equation is included in full-text article.)CV: 0.23 and rQE: 27.3), but significantly higher than the heterogeneity of architectural parameters within most carcinomas. In general, there was low to moderate variability of immunoexpression markers within each carcinoma, but estrogen receptor (mean CV: 0.56 and rQE: 46.2) and progesterone receptor (mean CV: 0.60 and rQE: 39.3) displayed the highest values of heterogeneity measures. Intratumoral heterogeneity of immunoexpression was significantly higher than that observed for morphometric parameters. In conclusion, our study indicates that endometrial carcinomas present a variable but predominantly low degree of phenotypic intratumoral heterogeneity.
Reliability of heart rate measures during walking before and after running maximal efforts.
Boullosa, D A; Barros, E S; del Rosso, S; Nakamura, F Y; Leicht, A S
2014-11-01
Previous studies on HR recovery (HRR) measures have utilized the supine and the seated postures. However, the most common recovery mode in sport and clinical settings after running exercise is active walking. The aim of the current study was to examine the reliability of HR measures during walking (4 km · h(-1)) before and following a maximal test. Twelve endurance athletes performed an incremental running test on 2 days separated by 48 h. Absolute (coefficient of variation, CV, %) and relative [Intraclass correlation coefficient, (ICC)] reliability of time domain and non-linear measures of HR variability (HRV) from 3 min recordings, and HRR parameters over 5 min were assessed. Moderate to very high reliability was identified for most HRV indices with short-term components of time domain and non-linear HRV measures demonstrating the greatest reliability before (CV: 12-22%; ICC: 0.73-0.92) and after exercise (CV: 14-32%; ICC: 0.78-0.91). Most HRR indices and parameters of HRR kinetics demonstrated high to very high reliability with HR values at a given point and the asymptotic value of HR being the most reliable (CV: 2.5-10.6%; ICC: 0.81-0.97). These findings demonstrate these measures as reliable tools for the assessment of autonomic control of HR during walking before and after maximal efforts. © Georg Thieme Verlag KG Stuttgart · New York.
Coefficient of variation for use in crop area classification across multiple climates
NASA Astrophysics Data System (ADS)
Whelen, Tracy; Siqueira, Paul
2018-05-01
In this study, the coefficient of variation (CV) is introduced as a unitless statistical measurement for the classification of croplands using synthetic aperture radar (SAR) data. As a measurement of change, the CV is able to capture changing backscatter responses caused by cycles of planting, growing, and harvesting, and thus is able to differentiate these areas from a more static forest or urban area. Pixels with CV values above a given threshold are classified as crops, and below the threshold are non-crops. This paper uses cross-polarized L-band SAR data from the ALOS PALSAR satellite to classify eleven regions across the United States, covering a wide range of major crops and climates. Two separate sets of classification were done, with the first targeting the optimum classification thresholds for each dataset, and the second using a generalized threshold for all datasets to simulate a large-scale operationalized situation. Overall accuracies for the first phase of classification ranged from 66%-81%, and 62%-84% for the second phase. Visual inspection of the results shows numerous possibilities for improving the classifications while still using the same classification method, including increasing the number and temporal frequency of input images in order to better capture phenological events and mitigate the effects of major precipitation events, as well as more accurate ground truth data. These improvements would make the CV method a viable tool for monitoring agriculture throughout the year on a global scale.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Wei; Li, Hong-Yi; Leung, L. Ruby
Anthropogenic activities, e.g., reservoir operation, may alter the characteristics of Flood Frequency Curve (FFC) and challenge the basic assumption of stationarity used in flood frequency analysis. This paper presents a combined data-modeling analysis of the nonlinear filtering effects of reservoirs on the FFCs over the contiguous United States. A dimensionless Reservoir Impact Index (RII), defined as the total upstream reservoir storage capacity normalized by the annual streamflow volume, is used to quantify reservoir regulation effects. Analyses are performed for 388 river stations with an average record length of 50 years. The first two moments of the FFC, mean annual maximummore » flood (MAF) and coefficient of variations (CV), are calculated for the pre- and post-dam periods and compared to elucidate the reservoir regulation effects as a function of RII. It is found that MAF generally decreases with increasing RII but stabilizes when RII exceeds a threshold value, and CV increases with RII until a threshold value beyond which CV decreases with RII. The processes underlying the nonlinear threshold behavior of MAF and CV are investigated using three reservoir models with different levels of complexity. All models capture the non-linear relationships of MAF and CV with RII, suggesting that the basic flood control function of reservoirs is key to the non-linear relationships. The relative roles of reservoir storage capacity, operation objectives, available storage prior to a flood event, and reservoir inflow pattern are systematically investigated. Our findings may help improve flood-risk assessment and mitigation in regulated river systems at the regional scale.« less
NASA Astrophysics Data System (ADS)
Doury, Maxime; Dizeux, Alexandre; de Cesare, Alain; Lucidarme, Olivier; Pellot-Barakat, Claire; Bridal, S. Lori; Frouin, Frédérique
2017-02-01
Dynamic contrast-enhanced ultrasound has been proposed to monitor tumor therapy, as a complement to volume measurements. To assess the variability of perfusion parameters in ideal conditions, four consecutive test-retest studies were acquired in a mouse tumor model, using controlled injections. The impact of mathematical modeling on parameter variability was then investigated. Coefficients of variation (CV) of tissue blood volume (BV) and tissue blood flow (BF) based-parameters were estimated inside 32 sub-regions of the tumors, comparing the log-normal (LN) model with a one-compartment model fed by an arterial input function (AIF) and improved by the introduction of a time delay parameter. Relative perfusion parameters were also estimated by normalization of the LN parameters and normalization of the one-compartment parameters estimated with the AIF, using a reference tissue (RT) region. A direct estimation (rRTd) of relative parameters, based on the one-compartment model without using the AIF, was also obtained by using the kinetics inside the RT region. Results of test-retest studies show that absolute regional parameters have high CV, whatever the approach, with median values of about 30% for BV, and 40% for BF. The positive impact of normalization was established, showing a coherent estimation of relative parameters, with reduced CV (about 20% for BV and 30% for BF using the rRTd approach). These values were significantly lower (p < 0.05) than the CV of absolute parameters. The rRTd approach provided the smallest CV and should be preferred for estimating relative perfusion parameters.
Shen, Cimin; Xu, Jinsen; Zheng, Shuxia; Lin, Lijiao; Yang, Xiaomei; Liu, Chunlan
2016-02-01
To observe the effect of electroacupuncture(EA) at Zhongwan(CV 12) on the energy metabolism along the conception vessel(CV) in volunteers with yang-deficiency constitution,and to explore the relationship of electroacupuncture regulation and body constitution. Eighteen volunteers with mild constitution and 18 volunteers with yang-deficiency constitution were collected out of 200 students of Fujian University of TCM by body constitution questionnaire. Skin microcirculatory blood perfusion units (MBPU) at Danzhong (CV 17), Xiawan(CV 10) and Qihai(CV 6) of CV were measured by a laser Doppler flowmetry in the normal condition and after EA stimulation at Zhongwan(CV 12) for 20 min. (1)Before treatment, (1)MBPU values at Danzhong(CV 17), Xiawan(CV 10) and Qihai(CV 6) in the yang-deficiency constitution group were lower than those in the mild constitution group,but there was no statistical significance (both P>0. 05) except Danzhong(CV 17) (P<0. 01). (Z)As for the three acupoints in the mild constitution group, MBPU level of Danzhong(CV 17) was higher than that of Xiawan(CV 10) without statistical significance(P->0. 05),and MBPU values of Danzhong(CV 17) and Xiawan(CV 10) were higher than that of Qihai(CV 6) (both P<0. 01). (3About the three acupoints in the yang-deficiency constitution group, MBPU result of Danzhong(CV 17) was lower than the value of Xiawan(CV 10), but higher compared with Qihai(CV 6)(P<0. 05, P<0. 01). MBPU of Xiawan(CV 10) was higher than Qihai (CV 6) as well(P<0. 01). (2) MBPU values of Danzhong(CV 17), Xiawan(CV 10) and Qihai(CV 6) were increased apparently compared with those before treatment after EA stimulation at Zhongwan(CV 12) for 20 min in the two groups(all P<0. 01). (3) The rise rates of MBPU level about Danzhong(CV 17) and Qihai(CV 6) in the yang-deficiency constitution group were higher than those in the mild constitution group without statistical significance after EA at Zhongwan(CV 12) for 20 min(both P>0. 05). The energy metabolism in CV of volunteers with yang-deficiency constitution is declined, especially Danzhong(CV 17). EA can rise energy metabolism in CV of mild or yang-deficiency constitution volunteers through regulating MBPU along meridian.
Hecker, Suzanne; Abrahamson, N.A.; Wooddell, Kathryn
2013-01-01
To investigate the nature of earthquake‐magnitude distributions on faults, we compare the interevent variability of surface displacement at a point on a fault from a composite global data set of paleoseismic observations with the variability expected from two prevailing magnitude–frequency distributions: the truncated‐exponential model and the characteristic‐earthquake model. We use forward modeling to predict the coefficient of variation (CV) for the alternative earthquake distributions, incorporating factors that would effect observations of displacement at a site. The characteristic‐earthquake model (with a characteristic‐magnitude range of ±0.25) produces CV values consistent with the data (CV∼0.5) only if the variability for a given earthquake magnitude is small. This condition implies that rupture patterns on a fault are stable, in keeping with the concept behind the model. This constraint also bears upon fault‐rupture hazard analysis, which, for lack of point‐specific information, has used global scaling relations to infer variability in average displacement for a given‐size earthquake. Exponential distributions of earthquakes (from M 5 to the maximum magnitude) give rise to CV values that are significantly larger than the empirical constraint. A version of the model truncated at M 7, however, yields values consistent with a larger CV (∼0.6) determined for small‐displacement sites. Although this result allows for a difference in the magnitude distribution of smaller surface‐rupturing earthquakes, it may reflect, in part, less stability in the displacement profile of smaller ruptures and/or the tails of larger ruptures.
40 CFR 53.55 - Test for effect of variations in power line voltage and ambient temperature.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within... absolute difference calculated in Equation 15 of this paragraph (g)(4) must not exceed 0.3 (CV%) for each test run. (5) Ambient temperature measurement accuracy. (i) Calculate the absolute value of the...
40 CFR 53.55 - Test for effect of variations in power line voltage and ambient temperature.
Code of Federal Regulations, 2014 CFR
2014-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within... absolute difference calculated in Equation 15 of this paragraph (g)(4) must not exceed 0.3 (CV%) for each test run. (5) Ambient temperature measurement accuracy. (i) Calculate the absolute value of the...
Technical performance of lactate biosensors and a test-strip device during labour.
Luttkus, A K; Fotopoulou, C; Sehouli, J; Stupin, J; Dudenhausen, J W
2010-04-01
Lactate in fetal blood has a high diagnostic power to detect fetal compromise due to hypoxia, as lactate allows an estimation of duration and intensity of metabolic acidemia. Biosensor technology allows an instantaneous diagnosis of fetal compromise in the delivery room. The goal of the current investigation is to define the preanalytical and analytical biases of this technology under routine conditions in a labour ward in comparison to test-strip technology, which allows measurement of lactate alone. Three lactate biosensors (RapidLab 865, Siemens Medical Solutions Diagnostics, Bad Nauheim, Germany; Radiometer ABL625 and ABL 700, Radiometer Copenhagen, Denmark) and one test-strip device (Lactate Pro, Oxford Instruments, UK) were evaluated regarding precision in serial and repetitive measurements in over 1350 samples of fetal whole blood. The coefficient of variation (CV) and the standard deviation (SD) were calculated. The average value of all three biosensors was defined as an artificial reference value (refval). Blood tonometry was performed in order to test the quality of respiratory parameters and to simulate conditions of fetal hypoxia (pO (2): 10 and 20 mmHg). The precision of serial measurements of all biosensors indicated a coefficient of variation (CV) between 1.55 and 3.16% with an SD from 0.042 to 0.053 mmol/L. The test-strip device (Lactate Pro) mounted to 0.117 mmol/L and 3.99% (SD, CV). When compared to our reference value (refval) ABL 625 showed the closest correlation of -0.1%, while Siemens RapidLab 865 showed an overestimation of +8.9%, ABL700 an underestimation of -6.2% and Lactate Pro of -3.7%. For routine use all tested biosensors show sufficient precision. The test-strip device shows a slightly higher standard deviation. A direct comparison of measured lactate values from the various devices needs to be interpreted with caution as each method detects different lactate concentrations. Furthermore, the 40 min process of tonometry led to an increase of SD and coefficient of variation in all devices. This results in the important preanalytical finding that the precision of replicated measurements worsens significantly with time. The clinician should be aware of the type of analyser used and of preanalytical biases before making clinical decisions on the basis of lactate values.
Choe, Leila H; Lee, Kelvin H
2003-10-01
We investigate one approach to assess the quantitative variability in two-dimensional gel electrophoresis (2-DE) separations based on gel-to-gel variability, sample preparation variability, sample load differences, and the effect of automation on image analysis. We observe that 95% of spots present in three out of four replicate gels exhibit less than a 0.52 coefficient of variation (CV) in fluorescent stain intensity (% volume) for a single sample run on multiple gels. When four parallel sample preparations are performed, this value increases to 0.57. We do not observe any significant change in quantitative value for an increase or decrease in sample load of 30% when using appropriate image analysis variables. Increasing use of automation, while necessary in modern 2-DE experiments, does change the observed level of quantitative and qualitative variability among replicate gels. The number of spots that change qualitatively for a single sample run in parallel varies from a CV = 0.03 for fully manual analysis to CV = 0.20 for a fully automated analysis. We present a systematic method by which a single laboratory can measure gel-to-gel variability using only three gel runs.
Variability of gait, bilateral coordination, and asymmetry in women with fibromyalgia.
Heredia-Jimenez, J; Orantes-Gonzalez, E; Soto-Hermoso, V M
2016-03-01
To analyze how fibromyalgia affected the variability, asymmetry, and bilateral coordination of gait walking at comfortable and fast speeds. 65 fibromyalgia (FM) patients and 50 healthy women were analyzed. Gait analysis was performed using an instrumented walkway (GAITRite system). Average walking speed, coefficient of variation (CV) of stride length, swing time, and step width data were obtained and bilateral coordination and gait asymmetry were analyzed. FM patients presented significantly lower speeds than the healthy group. FM patients obtained significantly higher values of CV_StrideLength (p=0.04; p<0.001), CV_SwingTime (p<0.001; p<0.001), CV_StepWidth (p=0.004; p<0.001), phase coordination index (p=0.01; p=0.03), and p_CV (p<0.001; p=0.001) than the control group, walking at comfortable or fast speeds. Gait asymmetry only showed significant differences in the fast condition. FM patients walked more slowly and presented a greater variability of gait and worse bilateral coordination than healthy subjects. Gait asymmetry only showed differences in the fast condition. The variability and the bilateral coordination were particularly affected by FM in women. Therefore, variability and bilateral coordination of gait could be analyzed to complement the gait evaluation of FM patients. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moore, B; Yin, F; Cai, J
Purpose: To determine the variation in tumor contrast between different MRI sequences and between patients for the purpose of MRI-based treatment planning. Methods: Multiple MRI scans of 11 patients with cancer(s) in the liver were included in this IRB-approved study. Imaging sequences consisted of T1W MRI, Contrast-Enhanced T1W MRI, T2W MRI, and T2*/T1W MRI. MRI images were acquired on a 1.5T GE Signa scanner with a four-channel torso coil. We calculated the tumor-to-tissue contrast to noise ratio (CNR) for each MR sequence by contouring the tumor and a region of interest (ROI) in a homogeneous region of the liver usingmore » the Eclipse treatment planning software. CNR was calculated (I-Tum-I-ROI)/SD-ROI, where I-Tum and I-ROI are the mean values of the tumor and the ROI respectively, and SD-ROI is the standard deviation of the ROI. The same tumor and ROI structures were used in all measurements for different MR sequences. Inter-patient Coefficient of variation (CV), and inter-sequence CV was determined. In addition, mean and standard deviation of CNR were calculated and compared between different MR sequences. Results: Our preliminary results showed large inter-patient CV (range: 37.7% to 88%) and inter-sequence CV (range 5.3% to 104.9%) of liver tumor CNR, indicating great variations in tumor CNR between MR sequences and between patients. Tumor CNR was found to be largest in CE-T1W (8.5±7.5), followed by T2W (4.2±2.4), T1W (3.4±2.2), and T2*/T1W (1.7±0.6) MR scans. The inter-patient CV of tumor CNR was also the largest in CE-T1W (88%), followed by T1W (64.3%), T1W (56.2%), and T2*/T1W (37.7) MR scans. Conclusion: Large inter-sequence and inter-patient variations were observed in liver tumor CNR. CE-T1W MR images on average provided the best tumor CNR. Efforts are needed to optimize tumor contrast and its consistency for MRI-based treatment planning of cancer in the liver. This project is supported by NIH grant: 1R21CA165384.« less
Impact of the definition of peak standardized uptake value on quantification of treatment response.
Vanderhoek, Matt; Perlman, Scott B; Jeraj, Robert
2012-01-01
PET-based treatment response assessment typically measures the change in maximum standardized uptake value (SUV(max)), which is adversely affected by noise. Peak SUV (SUV(peak)) has been recommended as a more robust alternative, but its associated region of interest (ROI(peak)) is not uniquely defined. We investigated the impact of different ROI(peak) definitions on quantification of SUV(peak) and tumor response. Seventeen patients with solid malignancies were treated with a multitargeted receptor tyrosine kinase inhibitor resulting in a variety of responses. Using the cellular proliferation marker 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT), whole-body PET/CT scans were acquired at baseline and during treatment. (18)F-FLT-avid lesions (∼2/patient) were segmented on PET images, and tumor response was assessed via the relative change in SUV(peak). For each tumor, 24 different SUV(peaks) were determined by changing ROI(peak) shape (circles vs. spheres), size (7.5-20 mm), and location (centered on SUV(max) vs. placed in highest-uptake region), encompassing different definitions from the literature. Within each tumor, variations in the 24 SUV(peaks) and tumor responses were measured using coefficient of variation (CV), standardized deviation (SD), and range. For each ROI(peak) definition, a population average SUV(peak) and tumor response were determined over all tumors. A substantial variation in both SUV(peak) and tumor response resulted from changing the ROI(peak) definition. The variable ROI(peak) definition led to an intratumor SUV(peak) variation ranging from 49% above to 46% below the mean (CV, 17%) and an intratumor SUV(peak) response variation ranging from 49% above to 35% below the mean (SD, 9%). The variable ROI(peak) definition led to a population average SUV(peak) variation ranging from 24% above to 28% below the mean (CV, 14%) and a population average SUV(peak) response variation ranging from only 3% above to 3% below the mean (SD, 2%). The size of ROI(peak) caused more variation in intratumor response than did the location or shape of ROI(peak). Population average tumor response was independent of size, shape, and location of ROI(peak). Quantification of individual tumor response using SUV(peak) is highly sensitive to the ROI(peak) definition, which can significantly affect the use of SUV(peak) for assessment of treatment response. Clinical trials are necessary to compare the efficacy of SUV(peak) and SUV(max) for quantification of response to therapy.
40 CFR 53.55 - Test for effect of variations in power line voltage and ambient temperature.
Code of Federal Regulations, 2012 CFR
2012-07-01
... temperatures used in the tests and shall be checked at zero and at least one flow rate within ±3 percent of 16... absolute difference calculated in Equation 15 of this paragraph (g)(4) must not exceed 0.3 (CV%) for each test run. (5) Ambient temperature measurement accuracy. (i) Calculate the absolute value of the...
40 CFR 53.55 - Test for effect of variations in power line voltage and ambient temperature.
Code of Federal Regulations, 2011 CFR
2011-07-01
... temperatures used in the tests and shall be checked at zero and at least one flow rate within ±3 percent of 16... absolute difference calculated in Equation 15 of this paragraph (g)(4) must not exceed 0.3 (CV%) for each test run. (5) Ambient temperature measurement accuracy. (i) Calculate the absolute value of the...
Wu, Xiaoping; Adriany, Gregor; Ugurbil, Kamil; Van de Moortele, Pierre-Francois
2013-01-01
Successful implementation of homogeneous slice-selective RF excitation in the human brain at 9.4T using 16-channel parallel transmission (pTX) is demonstrated. A novel three-step pulse design method incorporating fast real-time measurement of eddy current induced B0 variations as well as correction of resulting phase errors during excitation is described. To demonstrate the utility of the proposed method, phantom and in-vivo experiments targeting a uniform excitation in an axial slice were conducted using two-spoke pTX pulses. Even with the pre-emphasis activated, eddy current induced B0 variations with peak-to-peak values greater than 4 kHz were observed on our system during the rapid switches of slice selective gradients. This large B0 variation, when not corrected, resulted in drastically degraded excitation fidelity with the coefficient of variation (CV) of the flip angle calculated for the region of interest being large (~ 12% in the phantom and ~ 35% in the brain). By comparison, excitation fidelity was effectively restored, and satisfactory flip angle uniformity was achieved when using the proposed method, with the CV value reduced to ~ 3% in the phantom and ~ 8% in the brain. Additionally, experimental results were in good agreement with the numerical predictions obtained from Bloch simulations. Slice-selective flip angle homogenization in the human brain at 9.4T using 16-channel 3D spoke pTX pulses is achievable despite of large eddy current induced excitation phase errors; correcting for the latter was critical in this success.
Fiddler, W; Pensabene, J W; Gates, R A; Phillips, J G
1984-01-01
A dry column method for isolating N-nitrosopyrrolidine (NPYR) from fried, cure-pumped bacon and detection by gas chromatography-thermal energy analyzer (TEA) was studied collaboratively. Testing the results obtained from 11 collaborators for homogeneous variances among samples resulted in splitting the nonzero samples into 2 groups of sample levels, each with similar variances. Outlying results were identified by AOAC-recommended procedures, and laboratories having outliers within a group were excluded. Results from the 9 collaborators remaining in the low group yielded coefficients of variation (CV) of 6.00% and 7.47% for repeatability and reproducibility, respectively, and the 8 collaborators remaining in the high group yielded CV values of 5.64% and 13.72%, respectively. An 85.2% overall average recovery of the N-nitrosoazetidine internal standard was obtained with an average laboratory CV of 10.5%. The method has been adopted official first action as an alternative to the mineral oil distillation-TEA screening procedure.
Sales, J; Janssens, G P J
2003-09-01
The influence of length of excreta collection period (1, 3, 6, 10, 14 d) and prefeeding protocol (7 d either individual feeding in collection cages or group feeding in housing cages) on AMEn, nitrogen retention (NR), and apparent DM, organic matter and ether extract digestibility of corn and peas were evaluated in domestic pigeons (Columba livia domestica). In addition, the use of internal markers [acid-insoluble ash (AIA) and acid detergent lignin (ADL)] to determine AMEn, NR, and apparent digestibility was compared with the method of measuring total feed input and excreta output. A quadratic (y = a + bx + cx2) trend in the CV for AMEn, NR, and apparent digestibility coefficients found over collection periods with corn presented evidence that excreta collection for a period of 3 d will produce a CV of 5% less than the minimum CV. Although no trend could be detected in CV for peas, a 3-d excreta collection period resulted in relatively low variation. Both AIA and ADL, when used as internal markers, resulted in AMEn, NR, and digestibility values below (P < 0.05) those obtained with total collection with corn. However, values between markers were comparable (P > 0.05) for all components evaluated. The ADL was unsuccessful as marker with peas. Group prefeeding of pigeons in housing cages resulted in lower feed intake, excreta output, NR, and apparent digestibility than when birds were adapted individually to collection cages. This study presents evidence that the method of measuring total feed intake and excreta output for a period of 3 d, with individual adaptation of birds to collection cages, resulted in the most reliable values for AMEn, NR, and apparent digestibility of DM, organic matter and ether extract of feed ingredients in pigeons.
Image analysis of representative food structures: application of the bootstrap method.
Ramírez, Cristian; Germain, Juan C; Aguilera, José M
2009-08-01
Images (for example, photomicrographs) are routinely used as qualitative evidence of the microstructure of foods. In quantitative image analysis it is important to estimate the area (or volume) to be sampled, the field of view, and the resolution. The bootstrap method is proposed to estimate the size of the sampling area as a function of the coefficient of variation (CV(Bn)) and standard error (SE(Bn)) of the bootstrap taking sub-areas of different sizes. The bootstrap method was applied to simulated and real structures (apple tissue). For simulated structures, 10 computer-generated images were constructed containing 225 black circles (elements) and different coefficient of variation (CV(image)). For apple tissue, 8 images of apple tissue containing cellular cavities with different CV(image) were analyzed. Results confirmed that for simulated and real structures, increasing the size of the sampling area decreased the CV(Bn) and SE(Bn). Furthermore, there was a linear relationship between the CV(image) and CV(Bn) (.) For example, to obtain a CV(Bn) = 0.10 in an image with CV(image) = 0.60, a sampling area of 400 x 400 pixels (11% of whole image) was required, whereas if CV(image) = 1.46, a sampling area of 1000 x 100 pixels (69% of whole image) became necessary. This suggests that a large-size dispersion of element sizes in an image requires increasingly larger sampling areas or a larger number of images.
Liakos, Charalampos I; Karpanou, Eva A; Markou, Maria I; Grassos, Charalampos A; Vyssoulis, Gregory P
2015-12-01
Intrarenal hemodynamics depend on blood pressure (BP), heart rate (HR), and smoking. Although BP levels have been associated with kidney function, the effect of HR levels, BP, and HR variability on renal function are less well clarified. This cross-sectional study sought to determine the association of 24-hour BP and HR variability with kidney function in hypertensive patients, stratified by smoking. The study comprised 9600 nondiabetic, never-treated hypertensive individuals without evident renal impairment examined from 1985 to 2014 (aged 53.3±13.4 years, 55.3% males). The 24-hour systolic BP (SBP) and HR variability were estimated via their coefficient of variation (CV =standard deviation×100/mean value) derived from ambulatory recording. The CV SBP-to-CV HR ratio (CV R) was used as a marker of the interplay between 24-hour SBP and HR variability. Renal function was estimated via 24-hour urine creatinine clearance (CrCl), estimated glomerular filtration rate (eGFR), albumin-to-creatinine ratio (ACR), and 24-hour urine α1 -microglobulin. After adjustment for age, sex, and smoking, CV SBP was found to be weakly correlated to eGFR (r=-0.017, P=.1) and somewhat more strongly to CrCl, ACR, and α1 -microglobulin (r=-0.032, 0.072, and 0.065; P=.002, <.001 and <.001, respectively). CV HR was much better related to renal function, with stronger adjusted correlations to CrCl, eGFR, ACR, and α1 -microglobulin (r=0.185, 0.134, -0.306, -0.247; all P<.001, respectively). CV R also showed equally good adjusted correlations (r=-0.175, -0.125, 0.336, 0.262; all P<.001, respectively). Most adjusted correlations for CV HR and CV R were even better in smokers (r=0.213, 0.158, -0.332, -0.272 and -0.183, -0.118, 0.351, 0.275, respectively; all P<.001). CV HR and CV R emerge as better related to kidney function than CV SBP, especially in smokers. The correlation of CV HR and CV SBP to renal function is inverse to each other. ACR and α1 -microglobulin are better related to variability indices than CrCl and eGFR. However, causal relations cannot be proved. © 2015 Wiley Periodicals, Inc.
Wang, Xiaoxue; Li, Xuyong
2017-01-01
Particle grain size is an important indicator for the variability in physical characteristics and pollutants composition of road-deposited sediments (RDS). Quantitative assessment of the grain-size variability in RDS amount, metal concentration, metal load and GSFLoad is essential to elimination of the uncertainty it causes in estimation of RDS emission load and formulation of control strategies. In this study, grain-size variability was explored and quantified using the coefficient of variation (Cv) of the particle size compositions, metal concentrations, metal loads, and GSFLoad values in RDS. Several trends in grain-size variability of RDS were identified: (i) the medium class (105–450 µm) variability in terms of particle size composition, metal loads, and GSFLoad values in RDS was smaller than the fine (<105 µm) and coarse (450–2000 µm) class; (ii) The grain-size variability in terms of metal concentrations increased as the particle size increased, while the metal concentrations decreased; (iii) When compared to the Lorenz coefficient (Lc), the Cv was similarly effective at describing the grain-size variability, whereas it is simpler to calculate because it did not require the data to be pre-processed. The results of this study will facilitate identification of the uncertainty in modelling RDS caused by grain-size class variability. PMID:28788078
NASA Astrophysics Data System (ADS)
Bakoban, Rana A.
2017-08-01
The coefficient of variation [CV] has several applications in applied statistics. So in this paper, we adopt Bayesian and non-Bayesian approaches for the estimation of CV under type-II censored data from extension exponential distribution [EED]. The point and interval estimate of the CV are obtained for each of the maximum likelihood and parametric bootstrap techniques. Also the Bayesian approach with the help of MCMC method is presented. A real data set is presented and analyzed, hence the obtained results are used to assess the obtained theoretical results.
[Sincerity of effort: isokinetic evaluation of knee extension].
Colombo, R; Demaiti, G; Sartorio, F; Orlandini, D; Vercelli, S; Ferriero, G
2008-01-01
The aim of this study was to find a reliable method to evaluate the sincerity of the muscular maximal effort performed in a dynamometric isokinetic test of knee flexion-extension. The coefficient of variation of the peak torque (CV) and 3 new indices were analysed: (1) the average coefficient of variation calculated on the complete peak torque curve (CVM); (2) the slope of the regression line in an endurance test (PRR); (3) the correlation coefficient of the peak torques in the same endurance test (CCR). Twenty healthy subjects underwent assessment in two different trials, maximal (MX) and 50% submaximal (SMX), with 20 minutes of rest between trials. Each trial consisted of 4 tests, each of 3 repetitions, at angular speed of 30, 180, 30, and 180 degrees/s, respectively, and 1 test of 15 repetitions at 240 degrees/s. Our findings confirmed the ability of CV to detect a high percentage of sincere efforts: at 30 degrees/s Sensibility (Sns)=100% and Specificity (Spc)=70%; at 180 degrees/s Sns=75%, Spc=95%. The 3 new indices here proposed showed high characteristics of Sns and Spc, generally better than those of CV. CVM showed at 180 degrees/s Sns=90% and Spc=100%, while at 30 degrees/s Sns=90%, Spc=75%. PRR was the best index identifying all the efforts, except one (Sns=100%, Spc=95%). The CCR coefficient showed Sns and Spc values both of 90%.
Li, Tsai-Chung; Yang, Chun-Pai; Tseng, Shih-Ting; Li, Chia-Ing; Liu, Chiu-Shong; Lin, Wen-Yuan; Hwang, Kai-Lin; Yang, Sing-Yu; Chiang, Jen-Huai; Lin, Cheng-Chieh
2017-09-01
The relationship between glycemic variability and the incidence of Alzheimer disease (AD) in patients with type 2 diabetes mellitus (T2DM) is unclear. The aim of this study was to examine visit-to-visit variations in fasting plasma glucose (FPG) and glycated hemoglobin (HbA 1c ) represented by the coefficient of variation (CV) and to determine whether they were independently associated with AD, irrespective of HbA 1c and other traditional risk factors in such patients. Patients with T2DM enrolled in the National Diabetes Care Management Program, age ≥60 years, and without diagnosis of AD ( n = 16,706) were included in the study. Potential risk factors were analyzed using extended Cox proportional hazards regression models for competing risk of mortality on AD incidence. During a median follow-up of 8.88 years, 831 incident cases of AD were identified, with a crude incidence rate of 3.5/1,000 person-years. After adjustment for sociodemographic factors, lifestyle behaviors, diabetes-related variables, FPG and HbA 1c , drug-related variables, and comorbidities, both FPG CV and HbA 1c CV were found to be significant predictors of AD, with corresponding hazard ratios of 1.27 (95% CI 1.06-1.52) for the third tertile in FPG CV and 1.32 (95% CI 1.11-1.58) for the third tertile in HbA 1c CV. FPG CV and HbA 1c CV are independently associated with AD. The associations between glycemic variability and AD demonstrated in this study suggest a linked pathophysiological mechanism, which is worthy of further investigation. Further research is required to confirm our results and to evaluate whether FPG CV and HbA 1c CV can be valuable therapeutic targets for patients with T2DM at risk. © 2017 by the American Diabetes Association.
NASA Astrophysics Data System (ADS)
Zhou, Xiaomei; Zheng, Yun; Zhang, Tingting; Zhang, Xiaoqian; Ma, Mengli; Meng, Hengling; Wang, Tiantao; Lu, Bingyue
2018-06-01
In order to provide useful information for protection and utilization of red-grained rice landraces from Hani's terraced fields, the phenotypic diversity of 61 red-grained rice landraces were assessed based 20 quantitative traits. The results indicated that the phenotypic diversity was abundant in red-grained rice landraces. Coefficients of variation (CV) ranged from 4.878% to 72.878%, and the largest of CV was the panicle neck length, while grain width was smallest. Shannon-Weaver diversity index (H') of 20 traits ranged from 1.464 to 2.165, the largest and the smallest H' values were observed in filled grain number and chalkiness, respectively. Cluster analysis based on unweighted pair group method showed 61 red-grain rice landraces grouped into eight clusters at a cut-off value of 6.2631. The first cluster included 11 landraces, the main cluster II involved 42 landraces, and the cluster IV included 3 landraces. Laopinzhonghongmi, Chena2, Laojingnuo, Bianhao6 and Baimi were separated from the main clusters.
Cingü, Abdullah Kürşat; Sogutlu-Sari, Esin; Cınar, Yasin; Sahin, Muhammed; Türkçü, Fatih Mehmet; Yüksel, Harun; Sahin, Alparslan; Caça, Ihsan
2014-06-01
To evaluate the corneal endothelial changes following accelerated collagen cross-linking (CXL) for the treatment of progressive keratoconus. Thirty-six consecutive progressive keratoconus patients who received accelerated CXL treatment were enrolled in the study. Following de-epithelization, isoosmolar 0.1% riboflavin solution without dextran was instilled every 3 min throughout the 30 min of soaking time before the 5 min of 18 mW/cm(2) UVA irradiation and every 2 min during the UVA irradiation. Corneal specular microscopy was performed on both treated and fellow eyes of each patient preoperatively, in the first week, and in the first, third and sixth month postoperatively. There were significant differences in endothelial cell density (ECD), percentages of hexagonality (6A) and coefficient of variation of endothelial cell area (CV) in the first week and first month postoperatively in the treated eyes when compared to their preoperative values and also to the first week and first month ECD, 6A and CV values of the non-operative eyes. ECD returned to the preoperative values at sixth month whereas 6A and CV returned to the preoperative values at third month. Our results suggested that there may be transient changes in human corneal endothelium following accelerated UVA/riboflavin CXL. Resolution of these changes during the follow-up may indicate a safe recovery. However, the treatment guidelines for accelerated CXL including irradiance level and soaking time should be clearly established to minimize the toxic effects of the treatment.
Liu, Jiakai; Tan, Chin Hon; Badrick, Tony; Loh, Tze Ping
2018-02-01
An increase in analytical imprecision (expressed as CV a ) can introduce additional variability (i.e. noise) to the patient results, which poses a challenge to the optimal management of patients. Relatively little work has been done to address the need for continuous monitoring of analytical imprecision. Through numerical simulations, we describe the use of moving standard deviation (movSD) and a recently described moving sum of outlier (movSO) patient results as means for detecting increased analytical imprecision, and compare their performances against internal quality control (QC) and the average of normal (AoN) approaches. The power of detecting an increase in CV a is suboptimal under routine internal QC procedures. The AoN technique almost always had the highest average number of patient results affected before error detection (ANPed), indicating that it had generally the worst capability for detecting an increased CV a . On the other hand, the movSD and movSO approaches were able to detect an increased CV a at significantly lower ANPed, particularly for measurands that displayed a relatively small ratio of biological variation to CV a. CONCLUSION: The movSD and movSO approaches are effective in detecting an increase in CV a for high-risk measurands with small biological variation. Their performance is relatively poor when the biological variation is large. However, the clinical risks of an increase in analytical imprecision is attenuated for these measurands as an increased analytical imprecision will only add marginally to the total variation and less likely to impact on the clinical care. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Rate dependence of cell-to-cell variations of lithium-ion cells.
An, Fuqiang; Chen, Lufan; Huang, Jun; Zhang, Jianbo; Li, Ping
2016-10-11
Lithium-ion cells are commonly used in a multicell configuration in power devices and electric vehicles, making the cell-to-cell variation (CtCV) a key factor to consider in system design and management. Previous studies on CtCV have two major limitations: the number of cells is usually less than one hundred, and the cells are usually commercial cells already subjected to cell-screenings. In this article, we first make a statistical analysis on the CtCV of 5473 fresh cells from an automotive battery manufacturer before the cell-screening process. Secondly, 198 cells are randomly selected from these 5473 cells and the rate dependence of the CtCV is examined, focusing on the correlations of capacity versus weight and capacity versus resistance, corresponding to thermodynamic and kinetic factors, respectively. The rate dependence of these two correlations is explained from a phenomenological model. Finally, eight cells from the 198 cells are further characterized with electrochemical impedance spectroscopy method to elucidate the kinetic origins of the CtCV.
Rate dependence of cell-to-cell variations of lithium-ion cells
An, Fuqiang; Chen, Lufan; Huang, Jun; Zhang, Jianbo; Li, Ping
2016-01-01
Lithium-ion cells are commonly used in a multicell configuration in power devices and electric vehicles, making the cell-to-cell variation (CtCV) a key factor to consider in system design and management. Previous studies on CtCV have two major limitations: the number of cells is usually less than one hundred, and the cells are usually commercial cells already subjected to cell-screenings. In this article, we first make a statistical analysis on the CtCV of 5473 fresh cells from an automotive battery manufacturer before the cell-screening process. Secondly, 198 cells are randomly selected from these 5473 cells and the rate dependence of the CtCV is examined, focusing on the correlations of capacity versus weight and capacity versus resistance, corresponding to thermodynamic and kinetic factors, respectively. The rate dependence of these two correlations is explained from a phenomenological model. Finally, eight cells from the 198 cells are further characterized with electrochemical impedance spectroscopy method to elucidate the kinetic origins of the CtCV. PMID:27725767
Peppler, W T; Kim, W J; Ethans, K; Cowley, K C
2017-05-01
Methodological validation of dual-energy x-ray absorptiometry (DXA)-based measures of leg bone mineral density (BMD) based on the guidelines of the International Society for Clinical Densitometry. The primary objective of this study was to determine the precision of BMD estimates at the knee and heel using the manufacturer provided DXA acquisition algorithm. The secondary objective was to determine the smallest change in DXA-based measurement of BMD that should be surpassed (least significant change (LSC)) before suggesting that a biological change has occurred in the distal femur, proximal tibia and calcaneus. Academic Research Centre, Canada. Ten people with motor-complete SCI of at least 2 years duration and 10 people from the general population volunteered to have four DXA-based measurements taken of their femur, tibia and calcaneus. BMDs for seven regions of interest (RIs) were calculated, as were short-term precision (root-mean-square (RMS) standard deviation (g cm -2 ), RMS-coefficient of variation (RMS-CV, %)) and LSC. Overall, RMS-CV values were similar between SCI (3.63-10.20%, mean=5.3%) and able-bodied (1.85-5.73%, mean=4%) cohorts, despite lower absolute BMD values at each RIs in those with SCI (35%, heel to 54%, knee; P<0.0001). Precision was highest at the calcaneus and lowest at the femur. Except at the femur, RMS-CV values were under 6%. For DXA-based estimates of BMD at the distal femur, proximal tibia and calcaneus, these precision values suggest that LSC values >10% are needed to detect differences between treated and untreated groups in studies aimed at reducing bone mineral loss after SCI.
Sanchez, J; Dohoo, I R; Markham, F; Leslie, K; Conboy, G
2002-10-16
An indirect enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies against Ostertagia ostertagi using a crude adult worm antigen was evaluated using serum and milk samples from adult cows, as well as from bulk tank milk. Within and between plate repeatabilities were determined. In addition, the effects of factors such as antigen batch, freezing, preserving of the samples and somatic cell counts (SCCs) of the samples were evaluated. Raw optical densities (ODs) and normalized values were compared using the concordance correlation coefficient (CCC), the coefficient of variation (CV), Bland-Altman plots (BA). Based on raw OD values, there was a high repeatability within a plate (CCC approximately 0.96 and CV<10%). Repeatability between plates was evaluated following normalization of OD values by four methods. Computing normalized values as (OD-Nt)/(Pst-Nt), gave the most repeatable results, with the CCC being approximately 0.95 and the CV approximately 11%. When the OD values were higher than 1.2 and 0.3 for the positive and the negative controls, respectively, none of the normalization methods evaluated provided highly repeatable results and it was necessary to repeat the test. Two batches of the crude antigen preparation were evaluated for repeatability, and no difference was found (CCC=0.96). The use of preservative (bronopol) did not affect test results, nor did freezing the samples for up to 8 months. A significant positive relationship between ELISA OD for milk samples and SCC score was found. Therefore, the use of composite milk samples, which have less variable SCC than samples taken from each quarter, would be more suitable when the udder health status is unknown. The analytical methods used to evaluate repeatability provided a practical way to select among normalization procedures.
Strathe, A V; Strathe, A B; Theil, P K; Hansen, C F; Kebreab, E
2015-08-01
Determination of appropriate nutritional requirements is essential to optimize the productivity and longevity of lactating sows. The current recommendations for requirements do not consider the large variation between animals. Therefore, the aim of this study was to determine the amino acid recommendations for lactating sows using a stochastic modeling approach that integrates population variation and uncertainty of key parameters into establishing nutritional recommendations for lactating sows. The requirement for individual sows was calculated using a factorial approach by adding the requirement for maintenance and milk. The energy balance of the sows was either negative or zero depending on feed intake being a limiting factor. Some parameters in the model were sow-specific and others were population-specific, depending on state of knowledge. Each simulation was for 1000 sows repeated 100 times using Monte Carlo simulation techniques. BW, back fat thickness of the sow, litter size (LS), average litter gain (LG), dietary energy density and feed intake were inputs to the model. The model was tested using results from the literature, and the values were all within ±1 s.d. of the estimated requirements. Simulations were made for a group of low- (LS=10 (s.d.=1), LG=2 kg/day (s.d.=0.6)), medium- (LS=12 (s.d.=1), LG=2.5 kg/day (s.d.=0.6)) and high-producing (LS=14 (s.d.=1), LG=3.5 kg/day (s.d.=0.6)) sows, where the average requirement was the result. In another simulation, the requirements were estimated for each week of lactation. The results were given as the median and s.d. The average daily standardized ileal digestible (SID) protein and lysine requirements for low-, medium- and high-producing sows were 623 (CV=2.5%) and 45.1 (CV=4.8%); 765 (CV=4.9%) and 54.7 (CV=7.0%); and 996 (CV=8.5%) and 70.8 g/day (CV=9.6%), respectively. The SID protein and lysine requirements were lowest at week 1, intermediate at week 2 and 4 and the highest at week 3 of lactation. The model is a valuable tool to develop new feeding strategies by taking into account the variable requirement between groups of sows and changes during lactation. The inclusion of between-sow variation gives information on safety margins when developing new dietary recommendations of amino acids and protein for lactating sows.
Wu, Xiaoping; Adriany, Gregor; Ugurbil, Kamil; Van de Moortele, Pierre-Francois
2013-01-01
Successful implementation of homogeneous slice-selective RF excitation in the human brain at 9.4T using 16-channel parallel transmission (pTX) is demonstrated. A novel three-step pulse design method incorporating fast real-time measurement of eddy current induced B0 variations as well as correction of resulting phase errors during excitation is described. To demonstrate the utility of the proposed method, phantom and in-vivo experiments targeting a uniform excitation in an axial slice were conducted using two-spoke pTX pulses. Even with the pre-emphasis activated, eddy current induced B0 variations with peak-to-peak values greater than 4 kHz were observed on our system during the rapid switches of slice selective gradients. This large B0 variation, when not corrected, resulted in drastically degraded excitation fidelity with the coefficient of variation (CV) of the flip angle calculated for the region of interest being large (∼12% in the phantom and ∼35% in the brain). By comparison, excitation fidelity was effectively restored, and satisfactory flip angle uniformity was achieved when using the proposed method, with the CV value reduced to ∼3% in the phantom and ∼8% in the brain. Additionally, experimental results were in good agreement with the numerical predictions obtained from Bloch simulations. Slice-selective flip angle homogenization in the human brain at 9.4T using 16-channel 3D spoke pTX pulses is achievable despite of large eddy current induced excitation phase errors; correcting for the latter was critical in this success. PMID:24205098
Taguchi, Chie; Kishimoto, Yoshimi; Fukushima, Yoichi; Saita, Emi; Tanaka, Miori; Takahashi, Yoshinari; Masuda, Yasunobu; Goda, Toshinao; Kondo, Kazuo
2017-01-01
Polyphenol intake has been estimated in some populations; however, information about day-to-day and individual differences in polyphenol intake has not been well-evaluated. In this study, we aimed to examine within- and between-individual variation in polyphenol intake in Japanese male workers. First, 56 male subjects (aged 37.9±10.4 y) completed detailed 7-d dietary records (DR). We then calculated their total polyphenol intake using our polyphenol content database and the within- and between-individual variations. We also estimated the minimum number of days of dietary assessment required both to rank individuals within a group and to assess an individual's usual polyphenol intake with acceptable accuracy. The estimated daily total polyphenol intake was 965±471 mg/d, which was largely sourced from beverages. The day-to-day variation (CV w ) for polyphenol intake was 43.6%, and the variation between the individuals in the population (CV b ) for polyphenol intake was 45.9%. A 4-d DR was required to rank individuals within a group with high correlation coefficients (r=0.9), and a 19-d DR was required to assess the individual's usual polyphenol intake with 20% deviation. The CV w for polyphenol intake was intermediate between those of the other nutrients, but the CV b for polyphenol intake was largest among the nutrients. These results suggest that the dietary intake of polyphenols should be carefully estimated considering its within- and between-individual variation.
Ricotta, C.; Reed, B.C.; Tieszen, L.T.
2003-01-01
Time integrated normalized difference vegetation index (??NDVI) derived from National Oceanic and Atmospheric Administration (NOAA) Advanced Very High Resolution Radiometer (AVHRR) multi-temporal imagery over a 10-year period (1989-1998) was used as a surrogate for primary production to investigate the impact of interannual climate variability on grassland performance for central and northern US Great Plains. First, the contribution of C3 and C4 species abundance to the major grassland ecosystems of the US Great Plains is described. Next, the relation between mean ??NDVI and the ??NDVI coefficient of variation (CV ??NDVI) used as a proxy for interranual climate variability is analysed. Results suggest that the differences in the long-term climate control over ecosystem performance approximately coincide with changes between C3- and C4-dominant grassland classes. Variation in remotely sensed net primary production over time is higher for the southern and western plains grasslands (primary C4 grasslands), whereas the C3-dominated classes in the northern and eastern portion of the US Great Plains, generally show lower CV ??NDVI values.
Senn, Florian; Krykunov, Mykhaylo
2015-10-22
For the polyacenes series from naphthalene to hexacene, we present the vertical singlet excitation energies 1 (1)La and 1 (1)Lb, as well as the first triplet excitation energies obtained by the all-order constricted variational density functional theory with orbital relaxation (R-CV(∞)-DFT). R-CV(∞)-DFT is a further development of variational density functional theory (CV(∞)-DFT), which has already been successfully applied for the calculation of the vertical singlet excitation energies (1)La and (1)Lb for polyacenes,15 and we show that one obtains consistent excitation energies using the local density approximation as a functional for singlet as well as for triplet excitations when going beyond the linear response theory. Furthermore, we apply self-consistent field density functional theory (ΔSCF-DFT) and compare the obtained excitation energies for the first triplet excitations T1, where, due to the character of the transition, ΔSCF-DFT and R-CV(∞)-DFT become numerically equivalent, and for the singlet excitations 1 (1)La and 1 (1)Lb, where the two methods differ.
Mungovan, Sean F; Peralta, Paula J; Gass, Gregory C; Scanlan, Aaron T
2018-04-12
To examine the test-retest reliability and criterion validity of a high-intensity, netball-specific fitness test. Repeated measures, within-subject design. Eighteen female netball players competing in an international competition completed a trial of the Net-Test, which consists of 14 timed netball-specific movements. Players also completed a series of netball-relevant criterion fitness tests. Ten players completed an additional Net-Test trial one week later to assess test-retest reliability using intraclass correlation coefficient (ICC), typical error of measurement (TEM), and coefficient of variation (CV). The typical error of estimate expressed as CV and Pearson correlations were calculated between each criterion test and Net-Test performance to assess criterion validity. Five movements during the Net-Test displayed moderate ICC (0.84-0.90) and two movements displayed high ICC (0.91-0.93). Seven movements and heart rate taken during the Net-Test held low CV (<5%) with values ranging from 1.7 to 9.5% across measures. Total time (41.63±2.05s) during the Net-Test possessed low CV and significant (p<0.05) correlations with 10m sprint time (1.98±0.12s; CV=4.4%, r=0.72), 20m sprint time (3.38±0.19s; CV=3.9%, r=0.79), 505 Change-of-Direction time (2.47±0.08s; CV=2.0%, r=0.80); and maximum oxygen uptake (46.59±2.58 mLkg -1 min -1 ; CV=4.5%, r=-0.66). The Net-Test possesses acceptable reliability for the assessment of netball fitness. Further, the high criterion validity for the Net-Test suggests a range of important netball-specific fitness elements are assessed in combination. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Physiological responses at five estimates of critical velocity.
Bull, Anthony J; Housh, Terry J; Johnson, Glen O; Rana, Sharon R
2008-04-01
The purpose of this study was to compare critical velocity (CV) estimates from five mathematical models, and to examine the oxygen uptake (VO(2)) and heart rate (HR) responses during treadmill runs at the five estimates of CV. Ten subjects (six males and four females) performed one incremental test to determine maximal oxygen consumption (VO(2max)) and four or five randomly ordered constant-velocity trials on a treadmill for the estimation of CV. Five mathematical models were used to estimate CV for each subject including two linear, two nonlinear, and an exponential model. Up to five randomly ordered runs to exhaustion were performed by each subject at treadmill velocities that corresponded to the five CV estimates, and VO(2) and HR responses were monitored throughout each trial. The 3-parameter, nonlinear (Non-3) model produced CV estimates that were significantly (P < 0.05) less than the other four models. During runs at CV estimates, five subjects did not complete 60 min at the their estimate from the Non-3 model, nine did not complete 60 min at their estimate from the Non-2 model, and no subjects completed 60 min at any estimate from the other three models. The mean HR value (179 +/- 18 beats min(-1), HR(peak)) at the end of runs at CV using the Non-3 model was significantly less than the maximal HR (195 +/- 7 beats min(-1), HR(max)) achieved during the incremental trial to exhaustion. However, mean HR(peak) values from runs at all other CV estimates were not significantly different from HR(max). Furthermore, data indicated that mean HR(peak) values increased during runs at CV estimates from the third minute to the end of exercise for all models, and that these increases in VO(2) (range = 367-458 ml min(-1)) were significantly greater than that typically associated with O(2) drift ( approximately 200 ml min(-1)) for all but the exponential model, indicating a VO(2) slow component associated with CV estimates from four of the five models. However, the mean VO(2) values at the end of exercise during the runs at CV estimates for all five mathematical models were significantly less than the mean VO(2max) value. These results suggest that, in most cases, CV estimated from the five models does not represent a fatigueless task. In addition, the mean CV estimates from the five models varied by 18%, and four of the five mean CV estimates were within the heavy exercise domain. Therefore, CV would not represent the demarcation point between heavy and severe exercise domains.
[Evaluation of the Abbott Cell-Dyn Sapphire hematology analyzer].
Park, Younhee; Song, Jaewoo; Song, Sungwook; Song, Kyung Soon; Ahn, Mee Suk; Yang, Mi-Sook; Kim, Il; Choi, Jong Rak
2007-06-01
The performance of Cell-Dyn Sapphire (Abbott Diagnostic, USA) was compared to the Bayer Advia 2120 (Bayer Diagnostics, USA), Sysmex XE-2100 (Sysmex Corporation, Japan), and reference microscopy. Three hundred samples for routine CBC and WBC differentials were randomly chosen for a comparison analysis. The Cell-Dyn Sapphire system was evaluated according to the linearity, imprecision, inter-instrument correlations, and white blood cell differential. The CBC parameters (WBC, RBC, hemoglobin and platelet) showed a significant linearity with correlation coefficients greater than 0.99 (P<0.0001). Coefficients of variation (CV) for within-run and differential count of WBC were less than 5% except for Total CV for monocytes, eosinophils, and basophils and within-run CV for low valued eosinophils. The correlation coefficients with manual count were lower in monocytes, eosinophils, and basophils than in neutrophils and lymphocytes. The correlation with other hematology anlayzers was significant exclusive of basophils. These results demonstrate that the Cell-Dyn Sapphire has a good linearity, an acceptable reproducibility, a minimal carryover, and a comparable performance with the sysmex XE-2100 and Advia 2120.
Using CV-GLUE procedure in analysis of wetland model predictive uncertainty.
Huang, Chun-Wei; Lin, Yu-Pin; Chiang, Li-Chi; Wang, Yung-Chieh
2014-07-01
This study develops a procedure that is related to Generalized Likelihood Uncertainty Estimation (GLUE), called the CV-GLUE procedure, for assessing the predictive uncertainty that is associated with different model structures with varying degrees of complexity. The proposed procedure comprises model calibration, validation, and predictive uncertainty estimation in terms of a characteristic coefficient of variation (characteristic CV). The procedure first performed two-stage Monte-Carlo simulations to ensure predictive accuracy by obtaining behavior parameter sets, and then the estimation of CV-values of the model outcomes, which represent the predictive uncertainties for a model structure of interest with its associated behavior parameter sets. Three commonly used wetland models (the first-order K-C model, the plug flow with dispersion model, and the Wetland Water Quality Model; WWQM) were compared based on data that were collected from a free water surface constructed wetland with paddy cultivation in Taipei, Taiwan. The results show that the first-order K-C model, which is simpler than the other two models, has greater predictive uncertainty. This finding shows that predictive uncertainty does not necessarily increase with the complexity of the model structure because in this case, the more simplistic representation (first-order K-C model) of reality results in a higher uncertainty in the prediction made by the model. The CV-GLUE procedure is suggested to be a useful tool not only for designing constructed wetlands but also for other aspects of environmental management. Copyright © 2014 Elsevier Ltd. All rights reserved.
Liu, Guobing; Hu, Yan; Zhao, Yanzhao; Yu, Haojun; Hu, Pengcheng; Shi, Hongcheng
2018-05-01
To investigate the influence of background blood metabolism on liver uptake of 2-[F]fluoro-2-deoxy-D-glucose (F-FDG) and search for an appropriate corrective method.Positron emission tomography/computed tomography (PET/CT) and common serological biochemical tests of 633 healthy people were collected retrospectively. The mean standardized uptake value (SUV) of the liver, liver artery, and portal vein (i.e., SUVL, SUVA, and SUVP) were measured. SUVL/A was calculated as SUVL/SUVA, while SUVL/P was calculated as SUVL/SUVP. SUV of liver parenchyma (SUVLP) was calculated as SUVL - .3 × (.75 × SUVP + .25 × SUVA). The coefficients of variation (CV) of SUVL, SUVL/A, SUVL/P, and SUVLP were compared to assess their interindividual variations. Univariate and multivariate analyses were performed to identify vulnerabilities of these SUV indexes to common factors assessed using serological liver functional tests.SUVLP was significantly larger than SUVL (2.19 ± .497 vs 1.88 ± .495, P < .001), while SUVL/P was significantly smaller than SUVL (1.72 ± .454 vs 1.88 ± .495, P < .001). The difference between SUVL/A and SUVL was not significant (1.83 ± .500 vs 1.88 ± .495, P = .130). The CV of SUVLP (22.7%) was significantly smaller than that of SUVL (22.7%:26.3%, P < .001), while the CVs of SUVL/A (27.2%) and SUVL/P (26.4%) were not different from that of SUVL (P = .429 and .929, respectively). Fewer variables independently influenced SUVLP than influenced SUVL, SUVL/A, and SUVL/P; Only aspartate aminotransferase, body mass index, and total cholesterol, all P-values <.05.The activity of background blood influences the variation of liver SUV. SUVLP might be an alternative corrective method to reduce this influence, as its interindividual variation and vulnerability to effects from common factors of serological liver functional tests are relatively lower than the commonly used SUVL.
Light equation in eclipsing binary CV Boo: third body candidate in elliptical orbit
NASA Astrophysics Data System (ADS)
Bogomazov, A. I.; Kozyreva, V. S.; Satovskii, B. L.; Krushevska, V. N.; Kuznyetsova, Y. G.; Ehgamberdiev, S. A.; Karimov, R. G.; Khalikova, A. V.; Ibrahimov, M. A.; Irsmambetova, T. R.; Tutukov, A. V.
2016-12-01
A short period eclipsing binary star CV Boo is tested for the possible existence of additional bodies in the system with a help of the light equation method. We use data on the moments of minima from the literature as well as from our observations during 2014 May-July. A variation of the CV Boo's orbital period is found with a period of {≈}75 d. This variation can be explained by the influence of a third star with a mass of {≈}0.4 M_{⊙} in an eccentric orbit with e≈0.9. A possibility that the orbital period changes on long time scales is discussed. The suggested tertiary companion is near the chaotic zone around the central binary, so CV Boo represents an interesting example to test its dynamical evolution. A list of 14 minima moments of the binary obtained from our observations is presented.
Measurement of anterior tibial muscle size using real-time ultrasound imaging.
Martinson, H; Stokes, M J
1991-01-01
Cross-sectional images of the anterior tibial muscle group were obtained using real-time ultrasound scanning in 17 normal women. From photographs taken of the images, the cross-sectional area (CSA) and two linear measurements of muscle cross-section were determined. A measurement of the shortest distance of the muscle depth was termed DS, and a measurement of the longest distance through the muscle group was termed DL. Both linear dimensions showed a positive correlation with CSA and the best correlations were obtained when the dimensions were squared or combined (DS x DL). The correlation values were: CSA vs DS2, r = 0.9; CSA vs DL2, r = 0.75 and CSA vs DS x DL, r = 0.88. An approximate value for CSA could be calculated from DS2 by the equation 2 x DS2 + 1. A shape ratio, obtained by dividing DL by DS, was consistent within the group [mean 2.1 (SD 0.2)] and characterised the muscle geometrically. The CSA of repeated scans was assessed for repeatability between-days and between-scans by analysis of variance and the coefficient of variation (CV) calculated. Areas were repeatable between-days (CV 6.5%) and between-scans (CV 3.6%). Linear dimensions of the anterior tibial muscle group reflected CSA and their potential for assessing changes in muscle size with atrophy and hypertrophy have yet to be established.
Tang, Juan; Zhou, Xiangyang; Liu, Xiaochun; Ning, Leping; Zhou, Weiya; He, Yi
2017-09-01
The aim of this study is to improve the quality of testing for glucose-6-phosphate dehydrogenase (G6PD) deficiency through evaluation and analysis of the laboratory tests for G6PD activity. External quality assessment (EQA) was carried out twice per year with five samples each from 2014 to 2016. Samples were used for quantitative and qualitative assays. Quantitative results were collected, qualitative results were determined with reference values, and information about methods, reagents and instruments from participating laboratories within the required time. Laboratory performance scores, coefficient of variation (CV), and the rates of false negative and positive results were calculated. As a result, a total of 2,834 cases of negative quality control (QC) samples and 2,451 cases of positive QC samples were assessed, where the rates of false negative and false positive results were 1.31% (37/2,834) and 1.34% (33/2,451), respectively. Quantitative results indicated an increasing trend in testing quality, which were consistent with conclusions based on the comparison of EQA full-score and acceptable ratio in six assessments. The 2nd assay in 2016 had the best full-score ratio of 68.9% (135/196) and best acceptable ratio of 84.2% (165/196). There was a decreasing trend in the average CV of six reagents produced in China, and the range of average CV increased to 14.6-23.6% in 2016. The average CV of low level and high level samples was 22.5% and 15.3%, respectively, demonstrating that samples with low G6PD activity have greater interlaboratory CV values. In conclusion, laboratories improved their testing quality and provided better diagnostic service for G6PD deficiency in areas with high incidence after participation in the EQA program in the Guangxi region.
Vertical and horizontal facial proportions of Indian American men
2016-01-01
The importance of understanding all gender facial differences is critical in providing a successful cosmetic outcome. Men are a growing segment of the cosmetic industry. Understanding of the male face and its appropriate treatment with minimally invasive cosmetic procedures are essential. The aim was to investigate various facial ratios in Indian American men and to compare them with the Indian and Caucasian norms. Additionally, we wanted to evaluate whether these values satisfy golden and silver ratios. Direct facial anthropometric measurements were made using a digital caliper in 100 Indian American men students (18–30 years) at the American University of Antigua (AUA), Antigua. A set of facial ratios were calculated and compared with coefficients of variation (CV). Most of the facial ratios had small CV thus making them highly reliable due to reduced intra-sample variability. The upper face to face height and mandibulo upper face height indices were close to golden ratios whereas mandibulo lower face height, upper face height biocular width, and nasal indices were close to silver ratios. There was significant difference in most of the values when compared with previous studies. The present facial ratios data can be used as a reference value for Indian American men. PMID:27382514
Vertical and horizontal facial proportions of Indian American men.
Sadacharan, Chakravarthy Marx
2016-06-01
The importance of understanding all gender facial differences is critical in providing a successful cosmetic outcome. Men are a growing segment of the cosmetic industry. Understanding of the male face and its appropriate treatment with minimally invasive cosmetic procedures are essential. The aim was to investigate various facial ratios in Indian American men and to compare them with the Indian and Caucasian norms. Additionally, we wanted to evaluate whether these values satisfy golden and silver ratios. Direct facial anthropometric measurements were made using a digital caliper in 100 Indian American men students (18-30 years) at the American University of Antigua (AUA), Antigua. A set of facial ratios were calculated and compared with coefficients of variation (CV). Most of the facial ratios had small CV thus making them highly reliable due to reduced intra-sample variability. The upper face to face height and mandibulo upper face height indices were close to golden ratios whereas mandibulo lower face height, upper face height biocular width, and nasal indices were close to silver ratios. There was significant difference in most of the values when compared with previous studies. The present facial ratios data can be used as a reference value for Indian American men.
Effects of electrofishing gear type on spatial and temporal variability in fish community sampling
Meador, M.R.; McIntyre, J.P.
2003-01-01
Fish community data collected from 24 major river basins between 1993 and 1998 as part of the U.S. Geological Survey's National Water-Quality Assessment Program were analyzed to assess multiple-reach (three consecutive reaches) and multiple-year (three consecutive years) variability in samples collected at a site. Variability was assessed using the coefficient of variation (CV; SD/mean) of species richness, the Jaccard index (JI), and the percent similarity index (PSI). Data were categorized by three electrofishing sample collection methods: backpack, towed barge, and boat. Overall, multiple-reach CV values were significantly lower than those for multiple years, whereas multiple-reach JI and PSI values were significantly greater than those for multiple years. Multiple-reach and multiple-year CV values did not vary significantly among electrofishing methods, although JI and PSI values were significantly greatest for backpack electrofishing across multiple reaches and multiple years. The absolute difference between mean species richness for multiple-reach samples and mean species richness for multiple-year samples was 0.8 species (9.5% of total species richness) for backpack samples, 1.7 species (10.1%) for towed-barge samples, and 4.5 species (24.4%) for boat-collected samples. Review of boat-collected fish samples indicated that representatives of four taxonomic families - Catostomidae, Centrarchidae, Cyprinidae, and Ictaluridae - were collected at all sites. Of these, catostomids exhibited greater interannual variability than centrarchids, cyprinids, or ictalurids. Caution should be exercised when combining boat-collected fish community data from different years because of relatively high interannual variability, which is primarily due to certain relatively mobile species. Such variability may obscure longer-term trends.
Jaguemont, Joris; Van Den Bossche, Peter; Omar, Noshin; Van Mierlo, Joeri
2018-01-01
This paper examines the impact of the characterisation technique considered for the determination of the Li+ solid state diffusion coefficient in uncycled as in cycled Nickel Manganese Cobalt oxide (NMC) electrodes. As major characterisation techniques, Cyclic Voltammetry (CV), Galvanostatic Intermittent Titration Technique (GITT) and Electrochemical Impedance Spectroscopy (EIS) were systematically investigated. Li+ diffusion coefficients during the lithiation process of the uncycled and cycled electrodes determined by CV at 3.71 V are shown to be equal to 3.48×10−10 cm2·s−1 and 1.56×10−10 cm2·s−1 , respectively. The dependency of the Li+ diffusion with the lithium content in the electrodes is further studied in this paper with GITT and EIS. Diffusion coefficients calculated by GITT and EIS characterisations are shown to be in the range between 1.76×10−15 cm2·s−1 and 4.06×10−12 cm2·s−1, while demonstrating the same decreasing trend with the lithiation process of the electrodes. For both electrode types, diffusion coefficients calculated by CV show greater values compared to those determined by GITT and EIS. With ageing, CV and EIS techniques lead to diffusion coefficients in the electrodes at 3.71 V that are decreasing, in contrast to GITT for which results indicate increasing diffusion coefficient. After long-term cycling, ratios of the diffusion coefficients determined by GITT compared to CV become more significant with an increase about 1 order of magnitude, while no significant variation is seen between the diffusion coefficients calculated from EIS in comparison to CV. PMID:29360787
Dorajoo, Sreemanee Raaj; Ng, Joceline Shi Ling; Goh, Jessica Hui Fen; Lim, Su Chi; Yap, Chun Wei; Chan, Alexandre; Lee, Joyce Yu Chia
2017-06-01
To evaluate the association between HbA1c coefficient of variation (HbA1c-CV) and 3-year new-onset albuminuria risk. A retrospective cohort study involving 716 normoalbuminuric type 2 diabetes patients was conducted between 2010 and 2014. HbA1c-CV was used to categorize patients into low, moderate or high variability groups. Multivariate logistic models were constructed and validated. Integrated discrimination (IDI) and net reclassification (NRI) improvement indices were used to quantify the added predictive value of HbA1c-CV. The mean age of our cohort was 56.1±12.9years with a baseline HbA1c of 8.3±1.3%. Over 3-years of follow-up, 35.2% (n=252) developed albuminuria. An incremental risk of albuminuria was observed with moderate (6.68-13.43%) and high (above 13.44%) HbA1c-CV categories demonstrating adjusted odds ratios of 1.63 (1.12-2.38) and 3.80 (2.10-6.97) for 3-year new-onset albuminuria, respectively. Including HbA1c-CV for 3-year new-onset albuminuria prediction improved model discrimination (IDI: 0.023, NRI: 0.293, p<0.05). The final model had a C-statistic of 0.760±0.018 on validation. HbA1c-CV improves 3-year prediction of new-onset albuminuria. Together with mean HbA1c, baseline urine albumin-to-creatinine ratio and presence of hypertension, accurate 3-year new-onset albuminuria prediction may be possible. Copyright © 2017 Elsevier B.V. All rights reserved.
Capron, Odile; Gopalakrishnan, Rahul; Jaguemont, Joris; Van Den Bossche, Peter; Omar, Noshin; Van Mierlo, Joeri
2018-01-23
This paper examines the impact of the characterisation technique considered for the determination of the L i + solid state diffusion coefficient in uncycled as in cycled Nickel Manganese Cobalt oxide (NMC) electrodes. As major characterisation techniques, Cyclic Voltammetry (CV), Galvanostatic Intermittent Titration Technique (GITT) and Electrochemical Impedance Spectroscopy (EIS) were systematically investigated. L i + diffusion coefficients during the lithiation process of the uncycled and cycled electrodes determined by CV at 3.71 V are shown to be equal to 3 . 48 × 10 - 10 cm 2 ·s - 1 and 1 . 56 × 10 - 10 cm 2 ·s - 1 , respectively. The dependency of the L i + diffusion with the lithium content in the electrodes is further studied in this paper with GITT and EIS. Diffusion coefficients calculated by GITT and EIS characterisations are shown to be in the range between 1 . 76 × 10 - 15 cm 2 ·s - 1 and 4 . 06 × 10 - 12 cm 2 ·s - 1 , while demonstrating the same decreasing trend with the lithiation process of the electrodes. For both electrode types, diffusion coefficients calculated by CV show greater values compared to those determined by GITT and EIS. With ageing, CV and EIS techniques lead to diffusion coefficients in the electrodes at 3.71 V that are decreasing, in contrast to GITT for which results indicate increasing diffusion coefficient. After long-term cycling, ratios of the diffusion coefficients determined by GITT compared to CV become more significant with an increase about 1 order of magnitude, while no significant variation is seen between the diffusion coefficients calculated from EIS in comparison to CV.
Ziegler, Tom; Krykunov, Mykhaylo
2010-08-21
It is well known that time-dependent density functional theory (TD-DFT) based on standard gradient corrected functionals affords both a quantitative and qualitative incorrect picture of charge transfer transitions between two spatially separated regions. It is shown here that the well known failure can be traced back to the use of linear response theory. Further, it is demonstrated that the inclusion of higher order terms readily affords a qualitatively correct picture even for simple functionals based on the local density approximation. The inclusion of these terms is done within the framework of a newly developed variational approach to excitation energies called constrained variational density functional theory (CV-DFT). To second order [CV(2)-DFT] this theory is identical to adiabatic TD-DFT within the Tamm-Dancoff approximation. With inclusion of fourth order corrections [CV(4)-DFT] it affords a qualitative correct description of charge transfer transitions. It is finally demonstrated that the relaxation of the ground state Kohn-Sham orbitals to first order in response to the change in density on excitation together with CV(4)-DFT affords charge transfer excitations in good agreement with experiment. The new relaxed theory is termed R-CV(4)-DFT. The relaxed scheme represents an effective way in which to introduce double replacements into the description of single electron excitations, something that would otherwise require a frequency dependent kernel.
Reliability of anthropometric measurements in young male and female artistic gymnasts.
Siatras, Theophanis; Skaperda, Malamati; Mameletzi, Dimitra
2010-12-01
Body dimensions and body composition of children participating in artistic activities, such as gymnastics and many types of dancing, are important factors in performance improvement. The present study aimed to determine the reliability of a series of selected anthropometric measurements in young male and female gymnasts. Segment lengths, body breadths, circumferences, and skinfold thickness were measured in 20 young gymnasts by the same experienced examiner, using portable and easy-to-use instruments. All parameters were measured twice (test-retest) under the same conditions within a week's period. The high intra-class correlation coefficient (ICC) values ranging from 0.87 to 0.99, as well as the low coefficient of variation (CV) values (<5.3%), affirmed that the selected measurements were highly reliable. The technical error of measurement (TEM) values for lengths and breadths were 0.15 to 0.80 cm, for circumferences 0.22 to 1 cm, and for skinfold thickness 0.33 to 0.58 mm. The high test-retest ICC and the low CV and TEM values confirmed the reliability of all anthropometric measurements in young artistic gymnasts. Therefore, these measurements could contribute to further research in this field of investigation, helping to monitor young artistic gymnasts' growth status and identify specific characteristics for increased performance in this sport.
Heterogeneity measures in hydrological frequency analysis: review and new developments
NASA Astrophysics Data System (ADS)
Requena, Ana I.; Chebana, Fateh; Ouarda, Taha B. M. J.
2017-03-01
Some regional procedures to estimate hydrological quantiles at ungauged sites, such as the index-flood method, require the delineation of homogeneous regions as a basic step for their application. The homogeneity of these delineated regions is usually tested providing a yes/no decision. However, complementary measures that are able to quantify the degree of heterogeneity of a region are needed to compare regions, evaluate the impact of particular sites, and rank the performance of different delineating methods. Well-known existing heterogeneity measures are not well-defined for ranking regions, as they entail drawbacks such as assuming a given probability distribution, providing negative values and being affected by the region size. Therefore, a framework for defining and assessing desirable properties of a heterogeneity measure in the regional hydrological context is needed. In the present study, such a framework is proposed through a four-step procedure based on Monte Carlo simulations. Several heterogeneity measures, some of which commonly known and others which are derived from recent approaches or adapted from other fields, are presented and developed to be assessed. The assumption-free Gini index applied on the at-site L-variation coefficient (L-CV) over a region led to the best results. The measure of the percentage of sites for which the regional L-CV is outside the confidence interval of the at-site L-CV is also found to be relevant, as it leads to more stable results regardless of the regional L-CV value. An illustrative application is also presented for didactical purposes, through which the subjectivity of commonly used criteria to assess the performance of different delineation methods is underlined.
Winter, Randolph L; Saunders, Ashley B; Gordon, Sonya G; Buch, Jesse S; Miller, Matthew W
2017-04-01
To determine the biologic variability of N-terminal pro-brain natriuretic peptide (NTproBNP) in healthy dogs and dogs with various stages of myxomatous mitral valve disease (MMVD). Thirty-eight privately owned dogs: 28 with MMVD and 10 healthy controls. Prospective clinical study with comprehensive evaluation used to group dogs as healthy or into three stages of MMVD based on current guidelines. NTproBNP was measured hourly, daily, and weekly. For each group, analytical (CV A ), within-subject (CV I ), and between-subject (CV G ) coefficients of variability were calculated in addition to percent critical change value (CCV) and index of individuality (IoI). For healthy dogs, calculated NTproBNP values were: CV A = 4.2%; CV I = 25.2%; CV G = 49.3%; IoI = 0.52, and CCV = 70.8%. For dogs with MMVD, calculated NTproBNP values were: CV A = 6.2%; CV I = 20.0%; CV G = 61.3%; IoI = 0.34, and CCV = 58.2%. Biologic variability affects NTproBNP concentrations in healthy dogs and dogs with MMVD. Monitoring serial individual changes in NTproBNP may be clinically relevant in addition to using population-based reference ranges to determine changes in disease status. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freeman, M.N.; Marse, T.J.; Williams, P.L.
1998-12-31
In this study initial data were generated to develop laboratory control charts for aquatic toxicity testing using the nematode Caenorhabditis elegans. Tests were performed using two reference toxicants: CdCl{sub 2} and CuCl{sub 2}. All tests were performed for 24 h without a food source and of 48 h with a food source in a commonly used nematode aquatic medium. Each test was replicated 6 times with each replicate having 6 wells per concentration with 10 {+-} 1 worms per well. Probit analysis was used to estimate LC{sub 50} values for each test. The data were used to construct a meanmore » ({bar x}) laboratory control chart for each reference toxicant. The coefficient of variation (CV) for three of the four reference toxicant tests was less than 20%, which demonstrates an excellent degree of reproducibility. These CV values are well within suggested standards for determination of organism sensitivity and overall test system credibility. A standardized procedure for performing 24 h and 48 h aquatic toxicity studies with C. elegans is proposed.« less
[Study on the indexes of forensic identification by the occlusal-facial digital radiology].
Gao, Dong; Wang, Hu; Hu, Jin-liang; Xu, Zhe; Deng, Zhen-hua
2006-02-01
To discuss the coding of full dentition with 32 locations and measure the characteristics of some bony indexes in occlusal-facial digital radiology (DR). To select randomly three hundred DR orthopantomogram and code the full dentition, then analyze the diversity of dental patterns. To select randomly one hundred DR lateral cephalogram and measure six indexes (N-S,N-Me,Cd-Gn,Cd-Go,NP-SN,MP-SN) separately by one odontologist and one trained forensic graduate student, then calculate the coefficient variation (CV) of every index and take a correlation analysis for the consistency between two measurements. (1) The total diversity of 300 dental patterns was 75%.It was a very high value. (2)All six quantitative variables had comparatively high CV value.(3) After the linear correlation analysis between two measurements, all six coefficient correlations were close to 1. This indicated that the measurements were stable and consistent. The method of coding full dentition in DR orthopantomogram and measuring six bony indexes in DR lateral cephalogram can be used to forensic identification.
Short-term reliability of inflammatory mediators and response to exercise in the heat.
Guy, Joshua H; Edwards, Andrew M; Miller, Catherine M; Deakin, Glen B; Pyne, David B
2017-08-01
Prospective application of serum cytokines, lipopolysaccharide (LPS), and heat shock proteins (eHSPs) requires reliable measurement of these biomarkers that can signify exercise-induced heat stress in hot conditions. To accomplish this, both short-term (7 day) reliability (at rest, n = 12) and the acute responsiveness of each biomarker to exercise in the heat (pre and post 60-min cycling, 34.5°C and 70% RH, n = 20) were evaluated. Serum was analysed for the concentration of C-reactive protein (CRP), interleukin-6 (IL-6), heat shock protein 72 (eHSP72), immunoglobulin M (IgM) and LPS. Test-retest reliability was determined as the coefficient of variation (CV). Biomarkers with the least short-term within-participant variation were IL-6 (19%, ±20%; CV, ±95% confidence limits (CL)) and LPS (23%, ±13%). Greater variability was observed for IgM, eHSP72 and CRP (CV range 28-38%). IL-6 exhibited the largest increase in response to acute exercise (95%, ±11%, P = < 0.001) and although CRP had a modest CV (12%, ±7%), it increased substantially post-exercise (P = 0.02, ES; 0.78). In contrast, eHSP72 and LPS exhibited trivial changes post-exercise. It appears variation of common inflammatory markers after exercise in the heat is not always discernible from short-term (weekly) variation.
Corneal endothelial cell density and morphology in normal Iranian eyes
Hashemian, Mohammad Nasser; Moghimi, Sasan; Fard, Masood Aghsaie; Fallah, Mohammad Reza; Mansouri, Mohammad Reza
2006-01-01
Background We describe corneal endothelial cell density and morphology in normal Iranian eyes and compare endothelial cell characteristics in the Iranian population with data available in the literature for American and Indian populations. Methods Specular microscopy was performed in 525 eyes of normal Iranian people aged 20 to 85 years old. The studied parameters including mean endothelial cell density (MCD), mean cell area (MCA) and coefficient of variation (CV) in cell area were analyzed in all of the 525 eyes. Results MCD was 1961 ± 457 cell/mm2 and MCA was 537.0 ± 137.4 μm2. There was no statistically significant difference in MCD, MCA and CV between genders (Student t-test, P = 0.85, P = 0.97 and P = 0.15 respectively). There was a statistically significant decrease in MCD with age (P < 0.001, r = -0.64). The rate of cell loss was 0.6% per year. There was also a statistically significant increase in MCA (P < 0.001,r = 0.56) and CV (P < 0.001, r = 0.30) from 20 to 85 years of age. Conclusion The first normative data for the endothelium of Iranian eyes seems to confirm that there are no differences in MCD, MCA and CV between genders. Nevertheless, the values obtained in Iranian eyes seem to be different to those reported by the literature in Indian and American populations. PMID:16519812
Corneal endothelial cell density and morphology in normal Iranian eyes.
Hashemian, Mohammad Nasser; Moghimi, Sasan; Fard, Masood Aghsaie; Fallah, Mohammad Reza; Mansouri, Mohammad Reza
2006-03-06
We describe corneal endothelial cell density and morphology in normal Iranian eyes and compare endothelial cell characteristics in the Iranian population with data available in the literature for American and Indian populations. Specular microscopy was performed in 525 eyes of normal Iranian people aged 20 to 85 years old. The studied parameters including mean endothelial cell density (MCD), mean cell area (MCA) and coefficient of variation (CV) in cell area were analyzed in all of the 525 eyes. MCD was 1961 +/- 457 cell/mm2 and MCA was 537.0 +/- 137.4 microm2. There was no statistically significant difference in MCD, MCA and CV between genders (Student t-test, P = 0.85, P = 0.97 and P = 0.15 respectively). There was a statistically significant decrease in MCD with age (P < 0.001, r = -0.64). The rate of cell loss was 0.6% per year. There was also a statistically significant increase in MCA (P < 0.001,r = 0.56) and CV (P < 0.001, r = 0.30) from 20 to 85 years of age. The first normative data for the endothelium of Iranian eyes seems to confirm that there are no differences in MCD, MCA and CV between genders. Nevertheless, the values obtained in Iranian eyes seem to be different to those reported by the literature in Indian and American populations.
Bedner, Mary; Lippa, Katrice A; Tai, Susan S-C
2013-11-15
The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements, established the first accuracy-based program for improving the comparability of vitamin D metabolite measurements, the Vitamin D Metabolites Quality Assurance Program. The study samples were human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value. For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3),the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported. Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy. © 2013.
Bradshaw, Elizabeth Jane; Hume, Patria Anne; Aisbett, Brad
2012-01-01
We determined the inter-day variability in elite-standard women's artistic gymnastics competition scores. National (50 gymnasts for up to three days) and Olympic (24 gymnasts for up to five days) competition scores published in the public domain ('Giant poster pull-out', 2010 ; Gymnastics Australia, 2008 ) were evaluated using three statistical measures. Analyses of the inter-day differences in the mean scores as a percentage (MDiff%), coefficient of variation percentages for the mean score across both days (CV%), and Pearson correlation coefficients for the inter-day score (r) were interpreted using thresholds from trivial to large. National-class gymnasts' two-day performance variation was trivial for vault, small for floor and beam, and moderate for bars. When senior gymnasts competed for a third day the performance variation increased to moderate for vault. Across five days of Olympic competition there were trivial (e.g. CV%: vault = 0.8) to small (e.g. CV%: bars = 2.0) variations in performances between days on all apparatus. Olympians' performance score consistency is superior to senior, national-class competitors. The performance score consistency required for gymnasts who aspire to participate at the Olympics as a top-24 competitor is better than 3%.
Ducrot, Virginie; Askem, Clare; Azam, Didier; Brettschneider, Denise; Brown, Rebecca; Charles, Sandrine; Coke, Maïra; Collinet, Marc; Delignette-Muller, Marie-Laure; Forfait-Dubuc, Carole; Holbech, Henrik; Hutchinson, Thomas; Jach, Arne; Kinnberg, Karin L; Lacoste, Cédric; Le Page, Gareth; Matthiessen, Peter; Oehlmann, Jörg; Rice, Lynsey; Roberts, Edward; Ruppert, Katharina; Davis, Jessica Elphinstone; Veauvy, Clemence; Weltje, Lennart; Wortham, Ruth; Lagadic, Laurent
2014-12-01
The OECD test guideline development program has been extended in 2011 to establish a partial life-cycle protocol for assessing the reproductive toxicity of chemicals to several mollusk species, including the great pond snail Lymnaea stagnalis. In this paper, we summarize the standard draft protocol for a reproduction test with this species, and present inter-comparison results obtained in a 56-day prevalidation ring-test using this protocol. Seven European laboratories performed semi-static tests with cultured snails of the strain Renilys® exposed to nominal concentrations of cadmium chloride (from 53 to 608μgCdL(-1)). Cd concentrations in test solutions were analytically determined to confirm accuracy in the metal exposure concentrations in all laboratories. Physico-chemical and biological validity criteria (namely dissolved oxygen content >60% ASV, water temperature 20±1°C, control snail survival >80% and control snail fecundity >8 egg-masses per snail over the test period) were met in all laboratories which consistently demonstrated the reproductive toxicity of Cd in snails using the proposed draft protocol. Effect concentrations for fecundity after 56days were reproducible between laboratories (68
Zahedi, Edmond; Sohani, Vahid; Ali, M A Mohd; Chellappan, Kalaivani; Beng, Gan Kok
2015-01-01
The feasibility of a novel system to reliably estimate the normalized central blood pressure (CBPN) from the radial photoplethysmogram (PPG) is investigated. Right-wrist radial blood pressure and left-wrist PPG were simultaneously recorded in five different days. An industry-standard applanation tonometer was employed for recording radial blood pressure. The CBP waveform was amplitude-normalized to determine CBPN. A total of fifteen second-order autoregressive models with exogenous input were investigated using system identification techniques. Among these 15 models, the model producing the lowest coefficient of variation (CV) of the fitness during the five days was selected as the reference model. Results show that the proposed model is able to faithfully reproduce CBPN (mean fitness = 85.2% ± 2.5%) from the radial PPG for all 15 segments during the five recording days. The low CV value of 3.35% suggests a stable model valid for different recording days.
Robust Face Detection from Still Images
2014-01-01
significant change in false acceptance rates. Keywords— face detection; illumination; skin color variation; Haar-like features; OpenCV I. INTRODUCTION... OpenCV and an algorithm which used histogram equalization. The test is performed against 17 subjects under 576 viewing conditions from the extended Yale...original OpenCV algorithm proved the least accurate, having a hit rate of only 75.6%. It also had the lowest FAR but only by a slight margin at 25.2
Amita, Hidetoshi; Kim, Hyoung F; Smith, Mitchell; Gopal, Atul; Hikosaka, Okihide
2018-05-08
Direct and indirect pathways in the basal ganglia work together for controlling behavior. However, it is still a controversial topic whether these pathways are segregated or merged with each other. To address this issue, we studied the connections of these two pathways in the caudal parts of the basal ganglia of rhesus monkeys using anatomical tracers. Our previous studies showed that the caudal basal ganglia control saccades by conveying long-term values (stable values) of many visual objects toward the superior colliculus. In experiment 1, we injected a tracer in the caudate tail (CDt), and found local dense plexuses of axon terminals in the caudal-dorsal-lateral part of substantia nigra pars reticulata (cdlSNr) and the caudal-ventral part of globus pallidus externus (cvGPe). These anterograde projections may correspond to the direct and indirect pathways, respectively. To verify this in experiment 2, we injected different tracers into cdlSNr and cvGPe, and found many retrogradely labeled neurons in CDt and, in addition, the caudal-ventral part of the putamen (cvPut). These cdlSNr-projecting and cvGPe-projecting neurons were found intermingled in both CDt and cvPut (which we call 'striatum tail'). A small but significant proportion of neurons (< 15%) were double-labeled, indicating that they projected to both cdlSNr and cvGPe. These anatomical results suggest that stable value signals (good vs. bad) are sent from the striatum tail to cdlSNr and cvGPe in a biased (but not exclusive) manner. These connections may play an important role in biasing saccades toward higher-valued objects and away from lower-valued objects. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Ricotta, C.; Reed, Bradley C.; Tieszen, Larry L.
2003-01-01
Time integrated normalized difference vegetation index (ΣNDVI) derived from National Oceanic and Atmospheric Administration (NOAA) Advanced Very High Resolution Radiometer (AVHRR) multi-temporal imagery over a 10-year period (1989–1998) was used as a surrogate for primary production to investigate the impact of interannual climate variability on grassland performance for central and northern US Great Plains. First, the contribution of C3 and C4 species abundance to the major grassland ecosystems of the US Great Plains is described. Next, the relation between mean ΣNDVI and the ΣNDVI coefficient of variation (CV ΣNDVI) used as a proxy for interannual climate variability is analysed. Results suggest that the differences in the long-term climatic control over ecosystem performance approximately coincide with changes between C3- and C4-dominant grassland classes. Variation in remotely sensed net primary production over time is higher for the southern and western plains grasslands (primarily C4 grasslands), whereas the C3-dominated classes in the northern and eastern portion of the US Great Plains, generally show lower CV ΣNDVI values.
Reliability of performance of elite Olympic weightlifters.
McGuigan, Michael R; Kane, Melissa K
2004-08-01
There are no published data on the reliability of competitive strength performance, even though it has a pronounced effect on athletes' medal prospects and the ability of coaches and athletes to identify factors that affect competitive performance. The purpose of this investigation was to analyze the reliability of elite olympic weightlifters over a series of international weightlifting meets. We obtained official results of international competitions over an 18-month period from 1999 until the 2000 Olympic Games at the International Weightlifting Federation website. The measure of reliability was the typical within-athlete variation, derived as the coefficient of variation (CV) by 2-way analysis of variance of log-transformed weights lifted for the snatch, clean and jerk, and total. The results of this analysis were (a) within-athlete variations were as follows: snatch, 2.7% (95% likely range, 2.4-3.2%); clean and jerk, 2.3% (1.7-3.6%); total weight lifted, 2.5% (2.2-2.9%); (b) men and women: the variation was higher for the women compared with the men in both snatch (ratio of CV, 1.4) and clean and jerk (ratio of CV, 1.5), and for the total weight lifted (ratio of CV, 1.3); and (c) the top 5 athletes were almost always more reliable than the bottom-half athletes. Recent work has shown that the smallest worthwhile performance is about half the within-athlete variation, so coaches and sport scientists should focus on enhancements of as little as 1.2% in total weight lifted for elite olympic weightlifters.
Varea-Sánchez, María; Gómez Montoto, Laura; Tourmente, Maximiliano; Roldan, Eduardo R. S.
2014-01-01
Interspecific comparative studies have shown that, in most taxa, postcopulatory sexual selection (PCSS) in the form of sperm competition drives the evolution of longer and faster swimming sperm. Work on passserine birds has revealed that PCSS also reduces variation in sperm size between males at the intraspecific level. However, the influence of PCSS upon intra-male sperm size diversity is poorly understood, since the few studies carried out to date in birds have yielded contradictory results. In mammals, PCSS increases sperm size but there is little information on the effects of this selective force on variations in sperm size and shape. Here, we test whether sperm competition associates with a reduction in the degree of variation of sperm dimensions in rodents. We found that as sperm competition levels increase males produce sperm that are more similar in both the size of the head and the size of the flagellum. On the other hand, whereas with increasing levels of sperm competition there is less variation in head length in relation to head width (ratio CV head length/CV head width), there is no relation between variation in head and flagellum sizes (ratio CV head length/CV flagellum length). Thus, it appears that, in addition to a selection for longer sperm, sperm competition may select more uniform sperm heads and flagella, which together may enhance swimming velocity. Overall, sperm competition seems to drive sperm components towards an optimum design that may affect sperm performance which, in turn, will be crucial for successful fertilization. PMID:25243923
Baskan, Oguz; Kosker, Yakup; Erpul, Gunay
2013-12-01
Modeling spatio-temporal variation of soil moisture with depth in the soil profile plays an important role for semi-arid crop production from an agro-hydrological perspective. This study was performed in Guvenc Catchment. Two soil series that were called Tabyabayir (TaS) and Kervanpinari (KeS) and classified as Leptosol and Vertisol Soil Groups were used in this research. The TeS has a much shallower (0-34 cm) than the KeS (0-134 cm). At every sampling time, a total of geo-referenced 100 soil moisture samples were taken based on horizon depths. The results indicated that soil moisture content changed spatially and temporally with soil texture and profile depth significantly. In addition, land use was to be important factor when soil was shallow. When the soil conditions were towards to dry, higher values for the coefficient of variation (CV) were observed for TaS (58 and 43% for A and C horizons, respectively); however, the profile CV values were rather stable at the KeS. Spatial variability range of TaS was always higher at both dry and wet soil conditions when compared to that of KeS. Excessive drying of soil prevented to describe any spatial model for surface horizon, additionally resulting in a high nugget variance in the subsurface horizon for the TaS. On the contrary to TaS, distribution maps were formed all horizons for the KeS at any measurement times. These maps, depicting both dry and wet soil conditions through the profile depth, are highly expected to reduce the uncertainty associated with spatially and temporally determining the hydraulic responses of the catchment soils.
Reproducibility of an aerobic endurance test for nonexpert swimmers
Veronese da Costa, Adalberto; Costa, Manoel da Cunha; Carlos, Daniel Medeiros; Guerra, Luis Marcos de Medeiros; Silva, Antônio José; Barbosa, Tiago Manoel Cabral dos Santos
2012-01-01
Background: This study aimed to verify the reproduction of an aerobic test to determine nonexpert swimmers’ resistance. Methods: The sample consisted of 24 male swimmers (age: 22.79 ± 3.90 years; weight: 74.72 ± 11.44 kg; height: 172.58 ± 4.99 cm; and fat percentage: 15.19% ± 3.21%), who swim for 1 hour three times a week. A new instrument was used in this study (a Progressive Swim Test): the swimmer wore an underwater MP3 player and increased their swimming speed on hearing a beep after every 25 meters. Each swimmer’s heart rate was recorded before the test (BHR) and again after the test (AHR). The rate of perceived exertion (RPE) and the number of laps performed (NLP) were also recorded. The sample size was estimated using G*Power software (v 3.0.10; Franz Faul, Kiel University, Kiel, Germany). The descriptive values were expressed as mean and standard deviation. After confirming the normality of the data using both the Shapiro–Wilk and Levene tests, a paired t-test was performed to compare the data. The Pearson’s linear correlation (r) and intraclass coefficient correlation (ICC) tests were used to determine relative reproducibility. The standard error of measurement (SEM) and the coefficient of variation (CV) were used to determine absolute reproducibility. The limits of agreement and the bias of the absolute and relative values between days were determined by Bland–Altman plots. All values had a significance level of P < 0.05. Results: There were significant differences in AHR (P = 0.03) and NLP (P = 0.01) between the 2 days of testing. The obtained values were r > 0.50 and ICC > 0.66. The SEM had a variation of ±2% and the CV was <10%. Most cases were within the upper and lower limits of Bland–Altman plots, suggesting correlation of the results. The applicability of NLP showed greater robustness (r and ICC > 0.90; SEM < 1%; CV < 3%), indicating that the other variables can be used to predict incremental changes in the physiological condition of swimmers. Conclusion: The Progressive Swim Test for nonexpert swimmers produces comparable results for noncompetitive swimmers with a favorable degree of reproducibility, thus presenting possible applications for researching the physiological performance of nonexpert swimmers. PMID:23055740
Reproducibility of an aerobic endurance test for nonexpert swimmers.
Veronese da Costa, Adalberto; Costa, Manoel da Cunha; Carlos, Daniel Medeiros; Guerra, Luis Marcos de Medeiros; Silva, Antônio José; Barbosa, Tiago Manoel Cabral Dos Santos
2012-01-01
This study aimed to verify the reproduction of an aerobic test to determine nonexpert swimmers' resistance. The sample consisted of 24 male swimmers (age: 22.79 ± 3.90 years; weight: 74.72 ± 11.44 kg; height: 172.58 ± 4.99 cm; and fat percentage: 15.19% ± 3.21%), who swim for 1 hour three times a week. A new instrument was used in this study (a Progressive Swim Test): the swimmer wore an underwater MP3 player and increased their swimming speed on hearing a beep after every 25 meters. Each swimmer's heart rate was recorded before the test (BHR) and again after the test (AHR). The rate of perceived exertion (RPE) and the number of laps performed (NLP) were also recorded. The sample size was estimated using G*Power software (v 3.0.10; Franz Faul, Kiel University, Kiel, Germany). The descriptive values were expressed as mean and standard deviation. After confirming the normality of the data using both the Shapiro-Wilk and Levene tests, a paired t-test was performed to compare the data. The Pearson's linear correlation (r) and intraclass coefficient correlation (ICC) tests were used to determine relative reproducibility. The standard error of measurement (SEM) and the coefficient of variation (CV) were used to determine absolute reproducibility. The limits of agreement and the bias of the absolute and relative values between days were determined by Bland-Altman plots. All values had a significance level of P < 0.05. There were significant differences in AHR (P = 0.03) and NLP (P = 0.01) between the 2 days of testing. The obtained values were r > 0.50 and ICC > 0.66. The SEM had a variation of ±2% and the CV was <10%. Most cases were within the upper and lower limits of Bland-Altman plots, suggesting correlation of the results. The applicability of NLP showed greater robustness (r and ICC > 0.90; SEM < 1%; CV < 3%), indicating that the other variables can be used to predict incremental changes in the physiological condition of swimmers. The Progressive Swim Test for nonexpert swimmers produces comparable results for noncompetitive swimmers with a favorable degree of reproducibility, thus presenting possible applications for researching the physiological performance of nonexpert swimmers.
NASA Astrophysics Data System (ADS)
Gülnahar, Murat
2014-12-01
In this study, the current-voltage (I-V) and capacitance-voltage (C-V) measurements of an Au/4H-SiC Schottky diode are characterized as a function of the temperature in 50-300 K temperature range. The experimental parameters such as ideality factor and apparent barrier height presents to be strongly temperature dependent, that is, the ideality factor increases and the apparent barrier height decreases with decreasing temperature, whereas the barrier height values increase with the temperature for C-V data. Likewise, the Richardson plot deviates at low temperatures. These anomaly behaviors observed for Au/4H-SiC are attributed to Schottky barrier inhomogeneities. The barrier anomaly which relates to interface of Au/4H-SiC is also confirmed by the C-V measurements versus the frequency measured in 300 K and it is interpreted by both Tung's lateral inhomogeneity model and multi-Gaussian distribution approach. The values of the weighting coefficients, standard deviations and mean barrier height are calculated for each distribution region of Au/4H-SiC using the multi-Gaussian distribution approach. In addition, the total effective area of the patches NAe is obtained at separate temperatures and as a result, it is expressed that the low barrier regions influence meaningfully to the current transport at the junction. The homogeneous barrier height value is calculated from the correlation between the ideality factor and barrier height and it is noted that the values of standard deviation from ideality factor versus q/3kT curve are in close agreement with the values obtained from the barrier height versus q/2kT variation. As a result, it can be concluded that the temperature dependent electrical characteristics of Au/4H-SiC can be successfully commented on the basis of the thermionic emission theory with both models.
Leading causes of cardiovascular hospitalization in 8.45 million US veterans
Krishnamurthi, Nirupama; Francis, Joseph; Fihn, Stephan D.; Meyer, Craig S.
2018-01-01
Background We sought to determine the leading causes of cardiovascular (CV) hospitalization, and to describe and compare national rates of CV hospitalization by age, gender, race, ethnicity, region, and year, among U.S. veterans. Methods We evaluated the electronic health records of all veterans aged ≥18 years who had accessed any healthcare services at either a VA healthcare facility or a non-VA healthcare facility that was reimbursed by the VA, between January 1 2010 and December 31 2014. Among these 8,452,912 patients, we identified the 5 leading causes of CV hospitalization and compared rates of hospitalization by age, gender, race, ethnicity, region, year and type of VA healthcare user. Results The top 5 causes of CV hospitalization were: coronary atherosclerosis, heart failure, acute myocardial infarction, stroke and atrial fibrillation. Overall, 297,373 (3.5%) veterans were hospitalized for one or more of these cardiovascular conditions. The percentage of veterans hospitalized for one or more of these CV conditions decreased over time, from 1.23% in 2010 to 1.18% in 2013, followed by a slight increase to 1.20% in 2014. There was significant variation in rates of CV hospitalization by gender, race, ethnicity, geographic region, and urban vs. rural zip code. In particular, older, male, Black, non-Hispanic, urban and Continental region veterans experienced the highest rates of CV hospitalizations. Conclusions Among 8.5 million patients enrolled in the VA healthcare system from 2010 to 2014, there was substantial variation in rates of CV hospitalization by age, gender, race, geographical distribution, year, and use of non-VA (vs. VA only) healthcare care facilities. PMID:29566396
Stability of BUN and creatinine determinations on the Siemens Advia 1800 analyzer.
Qin, Jia; Wang, Huiying; Rets, Anton; Harari, Saul; Alexis, Herol; Eid, Ikram; Pincus, Matthew R
2013-11-01
Serum creatinine values of patients tend to change as a result of the use of different blanks used for creatinine determinations on the Advia 1650. After upgrading the analyzer to the Advia 1800, creatinine values tended to be more reproducible. As part of a quality assurance investigation to test the reproducibilities of creatinine values, we determined serial creatinine values in the sera of 13 patients whose initial values were either in the reference range or elevated (range 0.58-7.8 mg/dl). These values were determined concurrently with serum blood urea nitrogen (BUN) determinations (range 6.0-84.4 mg/dl) as these two analytes are used together in evaluation of renal function. We determined BUN and creatinine values, using the glutamate dehydrogenase lined enzyme assay system and the Jaffe method, respectively. We find that all values for creatinine on samples stored at 4 °C were reproducible as were the corresponding BUN values, which is revealed by low values for the coefficients of variation (CVs), that is, mean CV of 4.55% for creatinine and 2.52% for BUN. One sample with relatively high CV (10.6%) for creatinine was found to have an initial value of 1.1 mg/dl, in the reference range; but, on repeat determinations, the obtained levels were as high as 1.5 mg/dl, above the reference range. BUN values for this sample remained in the reference range, suggesting that no renal disease was present. We conclude that creatinine and BUN determinations are stable, but occasional spurious creatinine values can occur on the Advia 1800 analyzer. © 2013 Wiley Periodicals, Inc.
Usefulness of Maintaining a Normal Electrocardiogram Over Time for Predicting Cardiovascular Health.
Soliman, Elsayed Z; Zhang, Zhu-Ming; Chen, Lin Y; Tereshchenko, Larisa G; Arking, Dan; Alonso, Alvaro
2017-01-15
We hypothesized that maintaining a normal electrocardiogram (ECG) status over time is associated with low cardiovascular (CV) disease in a dose-response fashion and subsequently could be used to monitor programs aimed at promoting CV health. This analysis included 4,856 CV disease-free participants from the Atherosclerosis Risk in Communities study who had a normal ECG at baseline (1987 to 1989) and complete electrocardiographic data in subsequent 3 visits (1990 to 1992, 1993 to 1995, and 1996 to 1998). Participants were classified based on maintaining their normal ECG status during these 4 visits into "maintained," "not maintained," or "inconsistent" normal ECG status as defined by the Minnesota ECG classification. CV disease events (coronary heart disease, heart failure, and stroke) were adjudicated from Atherosclerosis Risk in Communities visit-4 through 2010. Over a median follow-up of 13.2 years, 885 CV disease events occurred. The incidence rate of CV disease events was lowest among study participants who maintained a normal ECG status, followed by those with an inconsistent pattern, and then those who did not maintain their normal ECG status (trend p value <0.001). Similarly, the greater the number of visits with a normal ECG status, the lower was the incidence rate of CV disease events (trend p value <0.001). Maintaining (vs not maintaining) a normal ECG status was associated with a lower risk of CV disease, which was lower than that observed in those with inconsistent normal ECG pattern (trend p value <0.01). In conclusion, maintaining a normal ECG status over time is associated with low risk of CV disease in a dose-response fashion, suggesting its potential use as a monitoring tool for programs promoting CV health. Copyright © 2016 Elsevier Inc. All rights reserved.
Intensity inhomogeneity correction for magnetic resonance imaging of human brain at 7T.
Uwano, Ikuko; Kudo, Kohsuke; Yamashita, Fumio; Goodwin, Jonathan; Higuchi, Satomi; Ito, Kenji; Harada, Taisuke; Ogawa, Akira; Sasaki, Makoto
2014-02-01
To evaluate the performance and efficacy for intensity inhomogeneity correction of various sequences of the human brain in 7T MRI using the extended version of the unified segmentation algorithm. Ten healthy volunteers were scanned with four different sequences (2D spin echo [SE], 3D fast SE, 2D fast spoiled gradient echo, and 3D time-of-flight) by using a 7T MRI system. Intensity inhomogeneity correction was performed using the "New Segment" module in SPM8 with four different values (120, 90, 60, and 30 mm) of full width at half maximum (FWHM) in Gaussian smoothness. The uniformity in signals in the entire white matter was evaluated using the coefficient of variation (CV); mean signal intensities between the subcortical and deep white matter were compared, and contrast between subcortical white matter and gray matter was measured. The length of the lenticulostriate (LSA) was measured on maximum intensity projection (MIP) images in the original and corrected images. In all sequences, the CV decreased as the FWHM value decreased. The differences of mean signal intensities between subcortical and deep white matter also decreased with smaller FWHM values. The contrast between white and gray matter was maintained at all FWHM values. LSA length was significantly greater in corrected MIP than in the original MIP images. Intensity inhomogeneity in 7T MRI can be successfully corrected using SPM8 for various scan sequences.
Lim, Sanghyeok; Kim, Seung Hyun; Kim, Yongsoo; Cho, Young Seo; Kim, Tae Yeob; Jeong, Woo Kyoung; Sohn, Joo Hyun
2018-02-01
To compare the diagnostic performance for advanced hepatic fibrosis measured by 2D shear-wave elastography (SWE), using either the coefficient of variance (CV) or the interquartile range divided by the median value (IQR/M) as quality criteria. In this retrospective study, from January 2011 to December 2013, 96 patients, who underwent both liver stiffness measurement by 2D SWE and liver biopsy for hepatic fibrosis grading, were enrolled. The diagnostic performances of the CV and the IQR/M were analyzed using receiver operating characteristic curves with areas under the curves (AUCs) and were compared by Fisher's Z test, based on matching the cutoff points in an interactive dot diagram. All P values less than 0.05 were considered significant. When using the cutoff value IQR/M of 0.21, the matched cutoff point of CV was 20%. When a cutoff value of CV of 20% was used, the diagnostic performance for advanced hepatic fibrosis ( ≥ F3 grade) with CV of less than 20% was better than that in the group with CV greater than or equal to 20% (AUC 0.967 versus 0.786, z statistic = 2.23, P = .025), whereas when the matched cutoff value IQR/M of 0.21 showed no difference (AUC 0.918 versus 0.927, z statistic = -0.178, P = .859). The validity of liver stiffness measurements made by 2D SWE for assessing advanced hepatic fibrosis may be judged using CVs, and when the CV is less than 20% it can be considered "more reliable" than using IQR/M of less than 0.21. © 2017 by the American Institute of Ultrasound in Medicine.
Sleep and the Cardiovascular System in Children.
Paul, Grace R; Pinto, Swaroop
2017-06-01
Subspecialty pediatric practice provides comprehensive medical care for a range of ages, from premature infants to children, and often includes adults with complex medical and surgical issues that warrant multidisciplinary care. Normal physiologic variations involving different body systems occur during sleep and these vary with age, stage of sleep, and underlying health conditions. This article is a concise review of the cardiovascular (CV) physiology and pathophysiology in children, sleep-disordered breathing (SDB) contributing to CV morbidity, congenital and acquired CV pathology resulting in SDB, and the relationship between SDB and CV morbidity in different clinical syndromes and systemic diseases in the expanded pediatric population. Copyright © 2017 Elsevier Inc. All rights reserved.
CAN CONTINGENT VALUATION MEASURE PASSIVE USE VALUES
Contingent valuation (CV) is the only method currently available for practically measuring passive-use values. Because proposed laws may require that environmental regulations pass a benefit-cost test, CV has become central to the policy debate on environmental protection. Crit...
Symstad, Amy J.; Jonas, Jayne L.; Edited by Guntenspergen, Glenn R.
2014-01-01
Natural range of variation (NRV) may be used to establish decision thresholds or action assessment points when ecological thresholds are either unknown or do not exist for attributes of interest in a managed ecosystem. The process for estimating NRV involves identifying spatial and temporal scales that adequately capture the heterogeneity of the ecosystem; compiling data for the attributes of interest via study of historic records, analysis and interpretation of proxy records, modeling, space-for-time substitutions, or analysis of long-term monitoring data; and quantifying the NRV from those data. At least 19 National Park Service (NPS) units in North America’s Great Plains are monitoring plant species richness and evenness as indicators of vegetation integrity in native grasslands, but little information on natural, temporal variability of these indicators is available. In this case study, we use six long-term vegetation monitoring datasets to quantify the temporal variability of these attributes in reference conditions for a variety of Great Plains grassland types, and then illustrate the implications of using different NRVs based on these quantities for setting management decision thresholds. Temporal variability of richness (as measured by the coefficient of variation, CV) is fairly consistent across the wide variety of conditions occurring in Colorado shortgrass prairie to Minnesota tallgrass sand savanna (CV 0.20–0.45) and generally less than that of production at the same sites. Temporal variability of evenness spans a greater range of CV than richness, and it is greater than that of production in some sites but less in other sites. This natural temporal variability may mask undesirable changes in Great Plains grasslands vegetation. Consequently, we suggest that managers consider using a relatively narrow NRV (interquartile range of all richness or evenness values observed in reference conditions) for designating a surveillance threshold, at which greater attention to the situation would be paid, and a broader NRV for designating management thresholds, at which action would be instigated.
Thogmartin, Wayne E.; Sanders-Reed, Carol A.; Szymanski, Jennifer; Pruitt, Lori; Runge, Michael C.
2017-01-01
Demographic characteristics of bats are often insufficiently described for modeling populations. In data poor situations, experts are often relied upon for characterizing ecological systems. In concert with the development of a matrix model describing Indiana bat (Myotis sodalis) demography, we elicited estimates for parameterizing this model from 12 experts. We conducted this elicitation in two stages, requesting expert values for 12 demographic rates. These rates were adult and juvenile seasonal (winter, summer, fall) survival rates, pup survival in fall, and propensity and success at breeding. Experts were most in agreement about adult fall survival (3% Coefficient of Variation) and least in agreement about propensity of juveniles to breed (37% CV). The experts showed greater concordance for adult ( mean CV, adult = 6.2%) than for juvenile parameters ( mean CV, juvenile = 16.4%), and slightly more agreement for survival (mean CV, survival = 9.8%) compared to reproductive rates ( mean CV, reproduction = 15.1%). However, survival and reproduction were negatively and positively biased, respectively, relative to a stationary dynamic. Despite the species exhibiting near stationary dynamics for two decades prior to the onset of a potential extinction-causing agent, white-nose syndrome, expert estimates indicated a population decline of -11% per year (95% CI = -2%, -20%); quasi-extinction was predicted within a century ( mean = 61 years to QE, range = 32, 97) by 10 of the 12 experts. Were we to use these expert estimates in our modeling efforts, we would have errantly trained our models to a rapidly declining demography asymptomatic of recent demographic behavior. While experts are sometimes the only source of information, a clear understanding of the temporal and spatial context of the information being elicited is necessary to guard against wayward predictions.
Niederer, Daniel; Vogt, Lutz; Wilke, Jan; Rickert, Marcus; Banzer, Winfried
2015-03-01
The present study aims to develop age-dependent cutoff values in a quasi-experimental, cross-sectional diagnostic test study. One hundred and twenty (120) asymptomatic subjects (n = 100, 36♀, 18 75 years, for normative values; n = 20, 23-75 years, 15♀, for selectivity analyses) and 20 patients suffering from idiopathic neck pain (selectivity analyses, 22-71 years, 15♀) were included. Subjects performed five repetitive maximal cervical flexion/extension movements in an upright sitting position. Cervical kinematic characteristics (maximal range of motion (ROM), coefficient of variation (CV) and mean conjunct movements in rotation and flexion (CM)) were calculated from raw 3D ultrasonic data. Regression analyses were conducted to reveal associations between kinematic characteristics and age and gender and thus to determine normative values for healthy subjects. Age explains 53 % of the variance in ROM (decrease 10.2° per decade), 13 % in CV (increase 0.003 per decade) and 9 % in CM (increase 0.57° per decade). Receivers operating characteristic (ROC) analyses were conducted for differences between individual values of the kinematic characteristics and normative values to optimise cutoff values for distinguishing patients from unimpaired subjects (20 patients and 20 healthy). Cutoff values distinguished asymptomatic subjects' and chronic nonspecific neck patient's movement characteristics with sufficient quality (sensitivity 70-80 %, specificity 65-70 %). By including such classifications, the present findings expand actual research stating an age-related decrease in kinematic behaviour only using categorising span widths across decades. Future study is warranted to reveal our results' potential applicability for intervention onset decision making for idiopathic neck pain patients.
Bedner, Mary; Lippa, Katrice A.; Tai, Susan S.-C.
2013-01-01
Background The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements, established the first accuracy-based program for improving the comparability of vitamin D metabolite measurements, the Vitamin D Metabolites Quality Assurance Program. Methods Study samples were comprised of human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value. Results For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3), the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported. Conclusions Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy. PMID:23978484
Multiplex serology of paraneoplastic antineuronal antibodies.
Maat, Peter; Brouwer, Eric; Hulsenboom, Esther; VanDuijn, Martijn; Schreurs, Marco W J; Hooijkaas, Herbert; Smitt, Peter A E Sillevis
2013-05-31
Paraneoplastic neurological syndromes (PNS) are devastating neurological disorders secondary to cancer, associated with onconeural autoantibodies. Such antibodies are directed against neuronal antigens aberrantly expressed by the tumor. The detection of onconeural antibodies in a patient is extremely important in diagnosing a neurological syndrome as paraneoplastic (70% is not yet known to have cancer) and in directing the search for the underlying neoplasm. At present six onconeural antibodies are considered 'well characterized' and recognize the antigens HuD, CDR62 (Yo), amphiphysin, CRMP-5 (CV2), NOVA-1 (Ri), and Ma2. The gold standard of detection is the characteristic immunohistochemical staining pattern on brain tissue sections combined with confirmation by immunoblotting using recombinant purified proteins. Since all six onconeural antibodies are usually analyzed simultaneously and objective cut-off values for these analyses are warranted, we developed a multiplex assay based on Luminex technology. Reaction of serial dilutions of six onconeural standard sera with microsphere-bound antigens showed lower limits of detection than with Western blotting. Using the six standard sera at a dilution of 1:200, the average within-run coefficient of variation (CV) was 4% (range 1.9-7.3%). The average between-run within-day CV was 5.1% (range 2.9-6.7%) while the average between-day CV was 8.1% (range 2.8-11.6%). The shelf-life of the antigen coupled microspheres was at least two months. The sensitivity of the multiplex assay ranged from 83% (Ri) to 100% (Yo, amphiphysin, CV2) and the specificity from 96% (CV2) to 100% (Ri). In conclusion, Luminex-based multiplex serology is highly reproducible with high sensitivity and specificity for the detection of onconeural antibodies. Conventional immunoblotting for diagnosis of onconeural antibodies in the setting of a routine laboratory may be replaced by this novel, robust technology. Copyright © 2013 Elsevier B.V. All rights reserved.
Wierzchowski, Paweł; Dereziński, Tadeusz; Migdalski, Arkadiusz; Woda, Łukasz; Wąsikowska, Beata; Jakubowski, Grzegorz; Jawień, Arkadiusz
2017-01-01
The incidence of peripheral artery disease (PAD) and cardiovascular (CV) events in the female population has been on the increase. To analyse the risk factors of a CV event and PAD in women and to assess the usefulness of the ankle-brachial index (ABI). Evaluation of selected parameters in a cohort of 365 women living in the same district. The following data were prospectively recorded: weight, height, waist size, hip circumference, smoking, the intima-media complex, ABI value, and laboratory results. PAD symptoms, CV events and neurological events were noted. ABI was analysed assuming pathology for values: ≤ 0.9 or ≤ 1.0. Age, plasma glucose level, atrial fibrillation, and nicotine addiction were correlated independently with CV disease and stroke (p < 0.001). The high-density lipoprotein cholesterol level, height, and systolic blood pressure were correlated independently with ABI values (p < 0.05). There was no correlation between the occurrence of a CV event in the past and the ABI, irrespective of the cut-off point for the reference value (p = NS). There is no evidence that stricter criteria for the assessment of ABI better represent the vascular status in the female population.
Beretta-Piccoli, Matteo; D'Antona, Giuseppe; Zampella, Cristian; Barbero, Marco; Clijsen, Ron; Cescon, Corrado
2017-04-01
The aim of this study was to determine the test-retest reliability of muscle fiber conduction velocity (CV) and fractal dimension (FD) obtained from multichannel surface electromyographic (sEMG) recordings. Forty healthy recreationally active subjects (20 men and 20 women) performed two elbow flexions on two trials with a 1 week interval. The first was a 20% maximal voluntary contraction (MVC) of 120 s, and the second at 60% MVC held until exhaustion. sEMG signals were detected from the biceps brachii, using bi-dimensional arrays. Initial values and slope of CV and FD were used for the reliability analysis. The intraclass correlation coefficient (ICC) values for the isometric contraction at 20% MVC were (-0.09) and 0.67 for CV and FD respectively; whereas the ICC values at 60% MVC were 0.78 and 0.82 for CV and FD respectively. The Bland Altman plots for the two isometric contractions showed a mean difference close to zero, with no evident outliers between the repeated measurements: at 20% MVC 0.001 53 for FD and -0.0277 for CV, and at 60% MVC 0.006 66 for FD and 0.009 07 for CV. Overall, our findings suggest that during isometric fatiguing contractions, CV and FD slopes are reliable variables, with potential application in clinical populations.
El Hawary, Seham S; Zaghloul, Soumaya S; El Halawany, Ali M; El Bishbishy, Mahitab H
2013-11-01
The volatile oils obtained from the leaves of four pecan cultivars growing in Egypt were evaluated for their chemical composition and antimicrobial activity. The selected cultivars (cv.) were Carya illinoinensis (Wangneh.) K. Koch. cv. Wichita, C. illinoinensis cv. Western Schley, C. illinoinensis cv. Cherokee, and C. illinoinensis cv. Sioux. The gas chromatography-mass spectrometry analyses revealed that the volatile oils from samples of the different cultivars differ in composition and percentage of their components. β-Curcumene was found as the major constituent of the cv. Wichita oil, whereas germacrene D was the major component of cv. Sioux, cv. Cherokee, and cv. Western Schley. The antimicrobial activity was assayed using the Kirby-Bauer Method by measuring the zone of inhibition of growth. All volatile oils displayed an antimicrobial activity against the tested bacterial strains. On the other hand, only the volatile oil of cv. Wichita showed an antifungal effect on Aspergillus flavus. This work has identified candidates of volatile oils for future in vivo studies to develop antibiotic substitutes for the diminution of human and animal pathogenic bacteria. Nevertheless, the variations of the volatile oil components and antimicrobial potencies of the different studied cultivars, necessitate identifying the cultivars used in future studies.
Puri, Basant K; Egan, Mary; Wallis, Fintan; Jakeman, Philip
2018-03-22
To investigate the repeatability of proton magnetic resonance spectroscopy in the in vivo measurement of human cerebral levels of choline-containing compounds (Cho). Two consecutive scans were carried out in six healthy resting subjects at a magnetic field strength of 1.5 T. On each occasion, neurospectroscopy data were collected from 64 voxels using the same 2D chemical shift imaging (CSI) sequence. The data were analyzed in the same way, using the same software, to obtain the values for each voxel of the ratio of Cho to creatine. The Wilcoxon related-samples signed-rank test, coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC) were used to assess the repeatability. The CV ranged from 2.75% to 33.99%, while the minimum RC was 5.68%. There was excellent reproducibility, as judged by significant ICC values, in 26 voxels. Just three voxels showed significant differences according to the Wilcoxon related-samples signed-rank test. It is therefore concluded that when CSI multivoxel proton neurospectroscopy is used to measure cerebral choline-containing compounds at 1.5 T, the reproducibility is highly acceptable.
Cringoli, Giuseppe; Rinaldi, Laura; Maurelli, Maria Paola; Morgoglione, Maria Elena; Musella, Vincenzo; Utzinger, Jürg
2011-05-01
We performed a calibration of flotation in tube, McMaster and FLOTAC to determine the optimal flotation solution (FS) and the influence of faecal preservation for the diagnosis of Ancylostoma caninum in dogs, and compared the accuracy of the three copromicroscopic techniques. Among nine different FS, sodium chloride and sodium nitrate performed best for detection and quantification of A. caninum eggs. Faecal samples, either fresh or preserved in formalin 5%, resulted in higher A. caninum egg counts, compared to frozen samples or preserved in formalin 10% or sodium acetate-acetic acid-formalin. FLOTAC consistently resulted in higher A. caninum eggs per gram of faeces (EPG) and lower coefficient of variation (CV) than McMaster and flotation in tube. The best results in terms of mean faecal egg counts (highest value, i.e. 117.0EPG) and CV (lowest value, i.e. 4.8%) were obtained with FLOTAC using sodium chloride and faecal samples preserved in formalin 5%. Our findings suggest that the FLOTAC technique should be considered for the diagnosis of A. caninum in dogs. Copyright © 2011 Elsevier Inc. All rights reserved.
Volcanoes Distribution in Linear Segmentation of Mariana Arc
NASA Astrophysics Data System (ADS)
Andikagumi, H.; Macpherson, C.; McCaffrey, K. J. W.
2016-12-01
A new method has been developed to describe better volcanoes distribution pattern within Mariana Arc. A previous study assumed the distribution of volcanoes in the Mariana Arc is described by a small circle distribution which reflects the melting processes in a curved subduction zone. The small circle fit to this dataset used in the study, comprised 12 -mainly subaerial- volcanoes from Smithsonian Institute Global Volcanism Program, was reassessed by us to have a root-mean-square misfit of 2.5 km. The same method applied to a more complete dataset from Baker et al. (2008), consisting 37 subaerial and submarine volcanoes, resulted in an 8.4 km misfit. However, using the Hough Transform method on the larger dataset, lower misfits of great circle segments were achieved (3.1 and 3.0 km) for two possible segments combination. The results indicate that the distribution of volcanoes in the Mariana Arc is better described by a great circle pattern, instead of small circle. Variogram and cross-variogram analysis on volcano spacing and volume shows that there is spatial correlation between volcanoes between 420 and 500 km which corresponds to the maximum segmentation lengths from Hough Transform (320 km). Further analysis of volcano spacing by the coefficient of variation (Cv), shows a tendency toward not-random distribution as the Cv values are closer to zero than one. These distributions are inferred to be associated with the development of normal faults at the back arc as their Cv values also tend towards zero. To analyse whether volcano spacing is random or not, Cv values were simulated using a Monte Carlo method with random input. Only the southernmost segment has allowed us to reject the null hypothesis that volcanoes are randomly spaced at 95% confidence level by 0.007 estimated probability. This result shows infrequent regularity in volcano spacing by chance so that controlling factor in lithospheric scale should be analysed with different approach (not from random number generator). Sunda Arc which has been studied to have en enchelon segmentation and larger number of volcanoes will be further studied to understand particular upper plate influence in volcanoes distribution.
Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Hayashi, Norio; Yamashita, Tomio; Matsunaga, Naofumi
2005-09-01
Deep-inspiratory breath-hold (DIBrH) Tc-99m-macroaggregated albumin (MAA) SPECT images were developed to accurately evaluate perfusion impairment in smokers' lungs. DIBrH SPECT was performed in 28 smokers with or without low attenuation areas (LAA) on CT images, using a triple-headed SPECT system and a laser light respiratory tracking device. DIBrH SPECT images were reconstructed from every 4 degrees projection of five adequate 360 degrees projection data sets with almost the same respiratory dimension at 20 sec DIBrH. Perfusion defect clarity was assessed by the lesion (defect)-to-contralateral normal lung count ratios (L/N ratios). Perfusion inhomogeneity was assessed by the coefficient of variation (CV) values of pixel counts and correlated with the diffusing capacity of the lungs for carbon monoxide/alveolar volume (DLCO/VA) ratios. The results were compared with those on conventional images. Five DIBrH projection data sets with minimal dimension differences of 2.9+/-0.6 mm were obtained in all subjects. DIBrH images enhanced perfusion defects compared with conventional images, with significantly higher L/N ratios (P<0.0001), and detected a total of 109 (26.9%) additional detects (513 vs. 404), with excellent inter-observer agreement (kappa value of 0.816). CV values in the smokers' lungs on DIBrH images were also significantly higher compared with those on conventional images (0.31+/-0.10 vs. 0.19+/-0.06, P<0.0001). CV values in smokers on DIBrH images showed a significantly closer correlation with DLCO/VA ratios compared with conventional images (R = 0.872, P<0.0001 vs. R=0.499, P<0.01). By reducing adverse effect of respiratory motion, DIBrH SPECT images enhance perfusion defect clarity and inhomogeneity, and provide more accurate assessment of impaired perfusion in smokers' lungs compared with conventional images.
NASA Astrophysics Data System (ADS)
Dhanya, M.; Chandrasekar, A.
2016-02-01
The background error covariance structure influences a variational data assimilation system immensely. The simulation of a weather phenomenon like monsoon depression can hence be influenced by the background correlation information used in the analysis formulation. The Weather Research and Forecasting Model Data assimilation (WRFDA) system includes an option for formulating multivariate background correlations for its three-dimensional variational (3DVar) system (cv6 option). The impact of using such a formulation in the simulation of three monsoon depressions over India is investigated in this study. Analysis and forecast fields generated using this option are compared with those obtained using the default formulation for regional background error correlations (cv5) in WRFDA and with a base run without any assimilation. The model rainfall forecasts are compared with rainfall observations from the Tropical Rainfall Measurement Mission (TRMM) and the other model forecast fields are compared with a high-resolution analysis as well as with European Centre for Medium-Range Weather Forecasts (ECMWF) ERA-Interim reanalysis. The results of the study indicate that inclusion of additional correlation information in background error statistics has a moderate impact on the vertical profiles of relative humidity, moisture convergence, horizontal divergence and the temperature structure at the depression centre at the analysis time of the cv5/cv6 sensitivity experiments. Moderate improvements are seen in two of the three depressions investigated in this study. An improved thermodynamic and moisture structure at the initial time is expected to provide for improved rainfall simulation. The results of the study indicate that the skill scores of accumulated rainfall are somewhat better for the cv6 option as compared to the cv5 option for at least two of the three depression cases studied, especially at the higher threshold levels. Considering the importance of utilising improved flow-dependent correlation structures for efficient data assimilation, the need for more studies on the impact of background error covariances is obvious.
Reproducibility of retinal vessel oxygen saturation measurements in healthy young subjects.
Lasta, Michael; Palkovits, Stefan; Boltz, Agnes; Schmidl, Doreen; Kaya, Semira; Cherecheanu, Alina Popa; Garhöfer, Gerhard; Schmetterer, Leopold
2012-12-01
An adequate oxygenation and perfusion is essential for the function of the inner retina. Recently, several techniques for the measurement of retinal oxygen saturation became available. We set out to evaluate reproducibility of the measurements using a modified Retinal Vessel Analyzer. A total of 20 healthy female and male subjects aged between 18 and 35 years (22.9 ± 3.9; mean ± SD) were included. The measurement of retinal oxygen saturation with the retinal oximeter employed in this study is based on optical reflectometry using the different absorption characteristics of oxygenated and deoxygenated haemoglobin. The intraclass correlation coefficients and the coefficients of variation (CV) for test-retest, short-term as well as day-to-day measurements were calculated. The intraclass correlation coefficients were between 0.91 and 0.94 for retinal branch arteries and between 0.84 and 0.88 for retinal branch veins. In retinal arteries, we calculated a test-retest CV of 3.24 ± 3.18% for oxygen saturation measurements. In retinal veins, data were slightly less reproducible with a CV of 4.92 ± 3.57%. Short-term reproducibility of both measurement cycles on each study day was in the same range (CV in retinal arteries: 2.91 ± 2.42% and CV in retinal veins: 4.76 ± 3.14%). The day-to-day coefficient of variation was slightly higher (CV in retinal arteries: 3.97 ± 2.87% and CV in retinal veins: 6.18 ± 3.36%). The reproducibility of haemoglobin oxygen saturation measurements using the retinal oximeter is acceptable. Further studies on the validity of the obtained results are, however, required. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Research on Customer Value Based on Extension Data Mining
NASA Astrophysics Data System (ADS)
Chun-Yan, Yang; Wei-Hua, Li
Extenics is a new discipline for dealing with contradiction problems with formulize model. Extension data mining (EDM) is a product combining Extenics with data mining. It explores to acquire the knowledge based on extension transformations, which is called extension knowledge (EK), taking advantage of extension methods and data mining technology. EK includes extensible classification knowledge, conductive knowledge and so on. Extension data mining technology (EDMT) is a new data mining technology that mining EK in databases or data warehouse. Customer value (CV) can weigh the essentiality of customer relationship for an enterprise according to an enterprise as a subject of tasting value and customers as objects of tasting value at the same time. CV varies continually. Mining the changing knowledge of CV in databases using EDMT, including quantitative change knowledge and qualitative change knowledge, can provide a foundation for that an enterprise decides the strategy of customer relationship management (CRM). It can also provide a new idea for studying CV.
2011-01-01
Background We characterized variation and chemical composition of epicuticular hydrocarbons (CHCs) in the seven species of the Drosophila buzzatii cluster with gas chromatography/mass spectrometry. Despite the critical role of CHCs in providing resistance to desiccation and involvement in communication, such as courtship behavior, mating, and aggregation, few studies have investigated how CHC profiles evolve within and between species in a phylogenetic context. We analyzed quantitative differences in CHC profiles in populations of the D. buzzatii species cluster in order to assess the concordance of CHC differentiation with species divergence. Results Thirty-six CHC components were scored in single fly extracts with carbon chain lengths ranging from C29 to C39, including methyl-branched alkanes, n-alkenes, and alkadienes. Multivariate analysis of variance revealed that CHC amounts were significantly different among all species and canonical discriminant function (CDF) analysis resolved all species into distinct, non-overlapping groups. Significant intraspecific variation was found in different populations of D. serido suggesting that this taxon is comprised of at least two species. We summarized CHC variation using CDF analysis and mapped the first five CHC canonical variates (CVs) onto an independently derived period (per) gene + chromosome inversion + mtDNA COI gene for each sex. We found that the COI sequences were not phylogenetically informative due to introgression between some species, so only per + inversion data were used. Positive phylogenetic signal was observed mainly for CV1 when parsimony methods and the test for serial independence (TFSI) were used. These results changed when no outgroup species were included in the analysis and phylogenetic signal was then observed for female CV3 and/or CV4 and male CV4 and CV5. Finally, removal of divergent populations of D. serido significantly increased the amount of phylogenetic signal as up to four out of five CVs then displayed positive phylogenetic signal. Conclusions CHCs were conserved among species while quantitative differences in CHC profiles between populations and species were statistically significant. Most CHCs were species-, population-, and sex-specific. Mapping CHCs onto an independently derived phylogeny revealed that a significant portion of CHC variation was explained by species' systematic affinities indicating phylogenetic conservatism in the evolution of these hydrocarbon arrays, presumptive waterproofing compounds and courtship signals as in many other drosophilid species. PMID:21699713
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shukla-Dave, A; Lu, Y; Hatzoglou, V
2014-06-15
Purpose: To investigate the repeatability of reduced field-of-view diffusion-weighted imaging (rFOV DWI) in quantifying apparent diffusion coefficients (ADCs) for human thyroid glands in a clinical setting. Methods: Nine healthy human volunteers were enrolled and underwent 3T MRI exams. For each volunteer, 3 longitudinal exams (2 weeks apart) with 2 repetitive sessions within each exam, including rFOV and conventional full field-of-view (fFOV) DWI scans, were performed. In the acquired DWI images, a fixed-size region of interest (ROI; diameter=8mm) was placed on thyroid glands to calculate ADC. ADC was calculated using a monoexponential function with a noise correction scheme. The repeatability ofmore » ADC was assessed by using coefficient variation (CV) across sessions or exams, which was defined to be: r = 1-CV, 0 < r < 1, where CV=STD/m, STD is the standard deviation of ADC, and m is the average of ADC across sessions or exams. An experienced radiologist assessed and scored rFOV and fFOV DW images based on image characteristics (1, nondiagnostic; 2, poor; 3, satisfactory; 4, good; and 5, excellent).Analysis of variance (ANOVA) was performed to compare ADC values, CV of ADC, repeatability of ADC across sessions and exams, and radiologic scores between rFOV and fFOV DWI techniques. Results: There was no significant difference in ADC values across sessions and exams either in rFOV or fFOV DWI. The average CVs of both rFOV and fFOV DWI were less than 13%. The repeatability of ADC measurement between rFOV and fFOV DWI was not significantly different. The overall image quality was significantly higher with rFOV DWI than with fFOV DWI. Conclusion: This study suggested that ADCs from both rFOV and fFOV DWI were repeatable, but rFOV DWI had superior imaging quality for human thyroid glands in a clinical setting.« less
Differential expression profiling of serum proteins and metabolites for biomarker discovery
NASA Astrophysics Data System (ADS)
Roy, Sushmita Mimi; Anderle, Markus; Lin, Hua; Becker, Christopher H.
2004-11-01
A liquid chromatography-mass spectrometry (LC-MS) proteomics and metabolomics platform is presented for quantitative differential expression analysis. Proteome profiles obtained from 1.5 [mu]L of human serum show ~5000 de-isotoped and quantifiable molecular ions. Approximately 1500 metabolites are observed from 100 [mu]L of serum. Quantification is based on reproducible sample preparation and linear signal intensity as a function of concentration. The platform is validated using human serum, but is generally applicable to all biological fluids and tissues. The median coefficient of variation (CV) for ~5000 proteomic and ~1500 metabolomic molecular ions is approximately 25%. For the case of C-reactive protein, results agree with quantification by immunoassay. The independent contributions of two sources of variance, namely sample preparation and LC-MS analysis, are respectively quantified as 20.4 and 15.1% for the proteome, and 19.5 and 13.5% for the metabolome, for median CV values. Furthermore, biological diversity for ~20 healthy individuals is estimated by measuring the variance of ~6500 proteomic and metabolomic molecular ions in sera for each sample; the median CV is 22.3% for the proteome and 16.7% for the metabolome. Finally, quantitative differential expression profiling is applied to a clinical study comparing healthy individuals and rheumatoid arthritis (RA) patients.
Saha, Supradip; Hedau, Nirmal K; Mahajan, Vinay; Singh, Gyanendra; Gupta, Hari S; Gahalain, Anita
2010-01-30
Screening of natural biodiversity for their better quality attributes is of prime importance for quality breeding programmes. A set of 53 tomato genotypes was measured for their textural [skin firmness, pericarp thickness, total soluble solids (TSS)], nutritional [phosphorus (P), potassium (K), iron (Fe), zinc (Zn), copper (Cu), manganese (Mn) and titrable acidity (TA)] and functional (beta-carotene, lycopene and ascorbic acid) quality attributes. Three sets of data (textural, nutritional and functional attributes) were obtained and analysed for their mutual relationships. Wide variations were observed in most of the measurements, e.g. skin firmness (coefficient of variability (CV) 269-612 g), pericarp thickness (CV 1.4-4.9 mm), potassium (CV 229-371 mg 100 g(-1)), iron (CV 611-1772 mg 100 g(-1)), ascorbic acid (CV 12-86 mg 100 g(-1)), suggesting that there are considerable levels of genetic diversity. Significant correlations (P < 0.05, 0.01) were also detected among different attributes of tomato genotypes, such as phosphorus and zinc with a correlation coefficient of 0.74, ascorbic acid and copper of 0.57, pericarp thickness and lycopene of - 0.52. However, there were no correlations between textural and nutritional attributes. Five factors were computed by principal component analysis that explained 66% of the variation in the attributes, among which all micronutrients other than iron, TSS, firmness and beta-carotene were most important. Functional attributes except beta-carotene played a less important role in explaining total variation. This knowledge could aid in the efficient conservation of important parts of the agricultural biodiversity of India. These results are also potentially useful for tomato breeders working on the development of new varieties. (c) 2009 Society of Chemical Industry.
Lowenthal, Mark S; Yen, James; Bunk, David M; Phinney, Karen W
2010-05-01
An isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) measurement procedure was developed to accurately quantify amino acid concentrations in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 2389a-amino acids in 0.1 mol/L hydrochloric acid. Seventeen amino acids were quantified using selected reaction monitoring on a triple quadrupole mass spectrometer. LC-MS/MS results were compared to gravimetric measurements from the preparation of SRM 2389a-a reference material developed at NIST and intended for use in intra-laboratory calibrations and quality control. Quantitative mass spectrometry results and gravimetric values were statistically combined into NIST-certified mass fraction values with associated uncertainty estimates. Coefficients of variation (CV) for the repeatability of the LC-MS/MS measurements among amino acids ranged from 0.33% to 2.7% with an average CV of 1.2%. Average relative expanded uncertainty of the certified values including Types A and B uncertainties was 3.5%. Mean accuracy of the LC-MS/MS measurements with gravimetric preparation values agreed to within |1.1|% for all amino acids. NIST SRM 2389a will be available for characterization of routine methods for amino acid analysis and serves as a standard for higher-order measurement traceability. This is the first time an ID LC-MS/MS methodology has been applied for quantifying amino acids in a NIST SRM material.
Learmonth, Yvonne C; Dlugonski, Deirdre D; Pilutti, Lara A; Sandroff, Brian M; Motl, Robert W
2013-11-01
Assessing walking impairment in those with multiple sclerosis (MS) is common, however little is known about the reliability, precision and clinically important change of walking outcomes. The purpose of this study was to determine the reliability, precision and clinically important change of the Timed 25-Foot Walk (T25FW), Six-Minute Walk (6MW), Multiple Sclerosis Walking Scale-12 (MSWS-12) and accelerometry. Data were collected from 82 persons with MS at two time points, six months apart. Analyses were undertaken for the whole sample and stratified based on disability level and usage of walking aids. Intraclass correlation coefficient (ICC) analyses established reliability: standard error of measurement (SEM) and coefficient of variation (CV) determined precision; and minimal detectable change (MDC) defined clinically important change. All outcome measures were reliable with precision and MDC varying between measures in the whole sample: T25FW: ICC=0.991; SEM=1 s; CV=6.2%; MDC=2.7 s (36%), 6MW: ICC=0.959; SEM=32 m; CV=6.2%; MDC=88 m (20%), MSWS-12: ICC=0.927; SEM=8; CV=27%; MDC=22 (53%), accelerometry counts/day: ICC=0.883; SEM=28450; CV=17%; MDC=78860 (52%), accelerometry steps/day: ICC=0.907; SEM=726; CV=16%; MDC=2011 (45%). Variation in these estimates was seen based on disability level and walking aid. The reliability of these outcomes is good and falls within acceptable ranges. Precision and clinically important change estimates provide guidelines for interpreting these outcomes in clinical and research settings.
Improvement and validation of the method to determine neutral detergent fiber in feed.
Hiraoka, Hisaaki; Fukunaka, Rie; Ishikuro, Eiichi; Enishi, Osamu; Goto, Tetsuhisa
2012-10-01
To improve the performance of the analytical method for neutral detergent fiber in feed with heat-stable α-amylase treatment (aNDFom), the process of adding heat-stable α-amylase, as well as other analytical conditions, were examined. In this new process, the starch in the samples was removed by adding amylase to neutral detergent (ND) solution twice, just after the start of heating and immediately after refluxing. We also examined the effects of the use of sodium sulfite, and drying and ashing conditions for aNDFom analysis by this modified amylase addition method. A collaborative study to validate this new method was carried out with 15 laboratories. These laboratories analyzed two samples, alfalfa pellet and dairy mixed feed, with blind duplicates. Ten laboratories used a conventional apparatus and five used a Fibertec(®) type apparatus. There were no significant differences in aNDFom values between these two refluxing apparatuses. The aNDFom values in alfalfa pellet and dairy mixed feed were 388 g/kg and 145 g/kg, the coefficients of variation for the repeatability and reproducibility (CV(r) and CV(R) ) were 1.3% and 2.9%, and the HorRat values were 0.8 and 1.1, respectively. This new method was validated with 5.8% uncertainty (k = 2) from the collaborative study. © 2012 The Authors. Animal Science Journal © 2012 Japanese Society of Animal Science.
The value of urban open space: meta-analyses of contingent valuation and hedonic pricing results.
Brander, Luke M; Koetse, Mark J
2011-10-01
Urban open space provides a number of valuable services to urban populations, including recreational opportunities, aesthetic enjoyment, environmental functions, and may also be associated with existence values. In separate meta-analyses of the contingent valuation (CV) and hedonic pricing (HP) literature we examine which physical, socio-economic, and study characteristics determine the value of open space. The dependent variable in the CV meta-regression is defined as the value of open space per hectare per year in 2003 US$, and in the HP model as the percentage change in house price for a 10 m decrease in distance to open space. Using a multi-level modelling approach we find in both the CV and HP analyses that there is a positive and significant relationship between the value of urban open space and population density, indicating that scarcity and crowdedness matter, and that the value of open space does not vary significantly with income. Further, urban parks are more highly valued than other types of urban open space (forests, agricultural and undeveloped land) and methodological differences in study design have a large influence on estimated values from both CV and HP. We also find important regional differences in preferences for urban open space, which suggests that the potential for transferring estimated values between regions is likely to be limited. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Erić, Suzana; Logar, Mihovil; Milovanović, Dragan; Babič, Danilo; Adnađević, Borivoj
2009-02-01
The study discusses the application of the Ti-in-biotite geothermometer of Henry et al. (2005) to the example of biotites from non-graphitic peraluminous micaschists of Central Serbia. Three petrographically different micaschists were distinguished on the basis of the following mineral assemblages: CV1 (St-Grt-Bt-Ms-Pg-Pl-Qtz), CV2 (Grt-St-Ky-Bt-Ms-Pl-Qtz) and RH (Grt-St-Bt-Ms-Pl-Qtz). Applying different geothermobarometers it was estimated that the studied micaschists were metamorphosed at average temperatures and pressures of 530 °C and 520 MPa (CV1incl), 580 °C and 670 MPa (CV1), 630 °C and 700 MPa (CV2) and 550 °C, 680 MPa (RH). The average temperatures obtained by the Ti-in-biotite method revealed uniform values for CV1 and CV2 micaschists and these values are very similar to the temperatures obtained by other methods. In contrast, the application of Ti-in-biotite geothermometer for RH micaschist yields the temperature difference of 85-110 °C. The variability of temperature is interpreted as a result of a positive correlation of Ti contents and XMg values in RH biotite, which is in disagreement with the principles of the Ti-in-biotite method. The positive Ti-XMg correlation is a result of the compositional variability shown by RH biotites from different samples, which can possibly be related to compositional inhomogeneities of the pelitic protolith. On the other hand, the Ti-in-biotite geothermometer for CV2 biotite gave very uniform temperatures despite variable Ti contents (Ti = 0.260, sd = 0.018 apfu). This is explained as result of the low sensitivity of Ti-in-biotite geothermometer for high Ti concentrations (> 0.25 apfu).
Weykamp, C W; Penders, T J; Miedema, K; Muskiet, F A; van der Slik, W
1995-01-01
We investigated the effect of calibration with lyophilized calibrators on whole-blood glycohemoglobin (glyHb) results. One hundred three laboratories, using 20 different methods, determined glyHb in two lyophilized calibrators and two whole-blood samples. For whole-blood samples with low (5%) and high (9%) glyHb percentages, respectively, calibration decreased overall interlaboratory variation (CV) from 16% to 9% and from 11% to 6% and decreased intermethod variation from 14% to 6% and from 12% to 5%. Forty-seven laboratories, using 14 different methods, determined mean glyHb percentages in self-selected groups of 10 nondiabetic volunteers each. With calibration their overall mean (2SD) was 5.0% (0.5%), very close to the 5.0% (0.3%) derived from the reference method used in the Diabetes Control and Complications Trial. In both experiments the Abbott IMx and Vision showed deviating results. We conclude that, irrespective of the analytical method used, calibration enables standardization of glyHb results, reference values, and interpretation criteria.
NASA Astrophysics Data System (ADS)
Ginting, M.; Aryanto, D.; Kurniawan, C.; Sari, A. Y.; Subhan, A.; Sudiro, T.; Sebayang, P.; Tarigan, E. R.; Nasruddin, M. N.; Sebayang, K.
2017-05-01
Zn0.95Ni0.05O has been synthesized by mixing 5% mol of NiO into ZnO using solid state reaction and high-speed shaker mill method. The samples were sintered at 900 °C with holding time for 2, 4 and 8 hours. Crystal structure, electrical and magnetic properties of Zn0.95Ni0.05O were characterized by using XRD, I-V, C-V and VSM. XRD results showed that variation of holding time does not change the structure of ZnO and no other secondary phase observed. The value of lattice parameters (a and c) tends to decrease proportionally to the holding time. The Intensity value changes and the peak shifted to a higher 2θ angle due to holding time variation. In general, the conductance of Zn0.95Ni0.05O decreases and the magnetic properties decrease also as the holding time is increased.
Health care contingent valuation studies: a review and classification of the literature.
Diener, A; O'Brien, B; Gafni, A
1998-06-01
The contingent valuation method (CVM) is a survey-based approach for eliciting consumer's monetary valuations for programme benefits for use in cost-benefit analysis (CBA). We used the conceptual framework of O'Brien and Gafni (1996) to classify and critically appraise health care CVM studies. Search of computerized health care and economic citation databases (e.g. MEDLINE, ECONLIT) and manual search for papers published between 1984 1996 reporting primary data valuing health programme benefits in monetary units by CVM using willingness-to-pay (WTP) or accept (WTA). We classified studies using both empirical (i.e. who was surveyed and how) and conceptual criteria (i.e. which measure of consumer utility was measured and why). 48 CVM studies were retrieved; the majority (42) undertook money valuation in the context of cost benefit analysis (CBA), with the remainder being pricing/demand studies. Among the 42 CBA studies, the consumer utility being measured (i.e. compensating (CV) vs. equivalent variation (EV) was explicitly stated in only three (7%) studies). WTP was measured in 95% of studies and WTA in 5%. By cross-tabulation, 42 (91%) studies were designed as WTP/CV, two (4%) were WTP/EV, two (4%) were WTA/CV and no studies used WTA/EV. Most studies were administered by mail (52%) with 38% being in-person interviews. Value elicitation techniques included open-ended questions (38%), payment cards (19%) discrete choice questions (26%) or bidding games (29%). Some form of construct validation tests, particularly associations between WTP and income, were done in 21 studies (50%). (i) The number of health care CVM studies is growing rapidly and the majority are done in the context of CBA; (ii) there is wide variation among health care CVM studies in terms of the types of questions being posed and the elicitation formats being used; (iii) classification and appraisal of the literature is difficult because reporting of methods and their relationship with the conceptual framework of CBA is poor; (iii) the applicability to health care of the CVM guidelines issued by the National Oceanic and Atmospheric Administration (NOAA) panel for environmental economics is unclear.
Improving the Signal-To-Noise Ratio When Monitoring Countermovement Jump Performance.
Kennedy, Rodney A; Drake, David
2018-05-08
Kennedy, RA and Drake, D. Improving the signal-to-noise ratio when monitoring countermovement jump performance. J Strength Cond Res XX(X): 000-000, 2018-Countermovement jump (CMJ) performance has been routinely used to monitor neuromuscular status. However, the protocol used to establish the criterion score is not well documented. The purpose of this study was to examine how the protocol used would influence of the sensitivity of CMJ variables in rugby union players. Fifteen male (age: 19.7 ± 0.5 years) rugby union players performed 8 CMJs on 2 occasions, separated by 7 days. The between-session coefficient of variation (CV) was calculated using 2 techniques for treating multiple trials, the average, and the trial with the best jump height (JH), and then compared with the smallest worthwhile change (SWC). The signal-to-noise ratio was measured as the group mean change in a variable divided by the CV. Using the average value across multiple trials is superior to the best trial method, based on lower CVs for all variables. Only the average performance across 6 or more trials was classified as ideal (CV < 0.5 × SWC) for peak velocity (PV). In addition, the signal-to-noise ratio for peak concentric power (PCP), PV, and JH were classified as good, irrespective of the treatment method. Although increasing the number of trials can reduce the random error, it may be pragmatic to simply take the average from 2 to 3 trials, facilitating a CV < SWC for PV, PCP, and JH. Due to its simplicity, JH may be considered the principal variable to monitor neuromuscular fatigue.
Thomsson, Ola; Ström-Holst, Bodil; Sjunnesson, Ylva; Bergqvist, Ann-Sofi
2014-09-06
The purpose of this study was to validate a commercially available enzyme-linked immunosorbent assay (ELISA) developed for measuring free cortisol in human saliva and total cortisol concentration in diluted human serum, for its applicability in measuring cortisol concentration in pig saliva. Collection of saliva is less stressful than e.g. blood sampling, and is a non-invasive method. Saliva was collected by allowing sows to chew on cotton swabs held by forceps. Thereafter, the swabs were centrifuged to retrieve the saliva. The ELISA was performed according to instructions provided by the manufacturer. To validate the ELISA, determination of the intra-assay coefficient of variation (CV), inter-assay CV, recovery, linearity and parallelism was performed. The intra-assay CV was below 10% and inter-assay CV below 15% for samples of high, medium and low cortisol concentrations. The mean recovery was 117% and the linearity and parallelism showed an r2-value of 0.994 and 0.993, respectively. For biological assessment of induced social stress, two saliva samples were collected in the morning from 6 primiparous and 21 multiparous sows. One sample was collected when the sows were individually housed in a farrowing pen and a second sample was collected when the sows were group housed. The primiparous sows had a significant higher cortisol concentration compared to the multiparous sows when group housed. The results obtained in this validation study indicate that the ELISA is suitable for measuring cortisol concentration in porcine saliva.
Maternal investment in reproduction and its consequences in leatherback turtles.
Wallace, Bryan P; Sotherland, Paul R; Tomillo, Pilar Santidrian; Reina, Richard D; Spotila, James R; Paladino, Frank V
2007-05-01
Maternal investment in reproduction by oviparous non-avian reptiles is usually limited to pre-ovipositional allocations to the number and size of eggs and clutches, thus making these species good subjects for testing hypotheses of reproductive optimality models. Because leatherback turtles (Dermochelys coriacea) stand out among oviparous amniotes by having the highest clutch frequency and producing the largest mass of eggs per reproductive season, we quantified maternal investment of 146 female leatherbacks over four nesting seasons (2001-2004) and found high inter- and intra-female variation in several reproductive characteristics. Estimated clutch frequency [coefficient of variation (CV) = 31%] and clutch size (CV = 26%) varied more among females than did egg mass (CV = 9%) and hatchling mass (CV = 7%). Moreover, clutch size had an approximately threefold higher effect on clutch mass than did egg mass. These results generally support predictions of reproductive optimality models in which species that lay several, large clutches per reproductive season should exhibit low variation in egg size and instead maximize egg number (clutch frequency and/or size). The number of hatchlings emerging per nest was positively correlated with clutch size, but fraction of eggs in a clutch yielding hatchlings (emergence success) was not correlated with clutch size and varied highly among females. In addition, seasonal fecundity and seasonal hatchling production increased with the frequency and the size of clutches (in order of effect size). Our results demonstrate that female leatherbacks exhibit high phenotypic variation in reproductive traits, possibly in response to environmental variability and/or resulting from genotypic variability within the population. Furthermore, high seasonal and lifetime fecundity of leatherbacks probably reflect compensation for high and unpredictable mortality during early life history stages in this species.
Cross Validation Through Two-Dimensional Solution Surface for Cost-Sensitive SVM.
Gu, Bin; Sheng, Victor S; Tay, Keng Yeow; Romano, Walter; Li, Shuo
2017-06-01
Model selection plays an important role in cost-sensitive SVM (CS-SVM). It has been proven that the global minimum cross validation (CV) error can be efficiently computed based on the solution path for one parameter learning problems. However, it is a challenge to obtain the global minimum CV error for CS-SVM based on one-dimensional solution path and traditional grid search, because CS-SVM is with two regularization parameters. In this paper, we propose a solution and error surfaces based CV approach (CV-SES). More specifically, we first compute a two-dimensional solution surface for CS-SVM based on a bi-parameter space partition algorithm, which can fit solutions of CS-SVM for all values of both regularization parameters. Then, we compute a two-dimensional validation error surface for each CV fold, which can fit validation errors of CS-SVM for all values of both regularization parameters. Finally, we obtain the CV error surface by superposing K validation error surfaces, which can find the global minimum CV error of CS-SVM. Experiments are conducted on seven datasets for cost sensitive learning and on four datasets for imbalanced learning. Experimental results not only show that our proposed CV-SES has a better generalization ability than CS-SVM with various hybrids between grid search and solution path methods, and than recent proposed cost-sensitive hinge loss SVM with three-dimensional grid search, but also show that CV-SES uses less running time.
The transfer functions of cardiac tissue during stochastic pacing.
de Lange, Enno; Kucera, Jan P
2009-01-01
The restitution properties of cardiac action potential duration (APD) and conduction velocity (CV) are important factors in arrhythmogenesis. They determine alternans, wavebreak, and the patterns of reentrant arrhythmias. We developed a novel approach to characterize restitution using transfer functions. Transfer functions relate an input and an output quantity in terms of gain and phase shift in the complex frequency domain. We derived an analytical expression for the transfer function of interbeat intervals (IBIs) during conduction from one site (input) to another site downstream (output). Transfer functions can be efficiently obtained using a stochastic pacing protocol. Using simulations of conduction and extracellular mapping of strands of neonatal rat ventricular myocytes, we show that transfer functions permit the quantification of APD and CV restitution slopes when it is difficult to measure APD directly. We find that the normally positive CV restitution slope attenuates IBI variations. In contrast, a negative CV restitution slope (induced by decreasing extracellular [K(+)]) amplifies IBI variations with a maximum at the frequency of alternans. Hence, it potentiates alternans and renders conduction unstable, even in the absence of APD restitution. Thus, stochastic pacing and transfer function analysis represent a powerful strategy to evaluate restitution and the stability of conduction.
Taimouri, Vahid; Afacan, Onur; Perez-Rossello, Jeannette M.; Callahan, Michael J.; Mulkern, Robert V.; Warfield, Simon K.; Freiman, Moti
2015-01-01
Purpose: To evaluate the effect of the spatially constrained incoherent motion (SCIM) method on improving the precision and robustness of fast and slow diffusion parameter estimates from diffusion-weighted MRI in liver and spleen in comparison to the independent voxel-wise intravoxel incoherent motion (IVIM) model. Methods: We collected diffusion-weighted MRI (DW-MRI) data of 29 subjects (5 healthy subjects and 24 patients with Crohn’s disease in the ileum). We evaluated parameters estimates’ robustness against different combinations of b-values (i.e., 4 b-values and 7 b-values) by comparing the variance of the estimates obtained with the SCIM and the independent voxel-wise IVIM model. We also evaluated the improvement in the precision of parameter estimates by comparing the coefficient of variation (CV) of the SCIM parameter estimates to that of the IVIM. Results: The SCIM method was more robust compared to IVIM (up to 70% in liver and spleen) for different combinations of b-values. Also, the CV values of the parameter estimations using the SCIM method were significantly lower compared to repeated acquisition and signal averaging estimated using IVIM, especially for the fast diffusion parameter in liver (CVIV IM = 46.61 ± 11.22, CVSCIM = 16.85 ± 2.160, p < 0.001) and spleen (CVIV IM = 95.15 ± 19.82, CVSCIM = 52.55 ± 1.91, p < 0.001). Conclusions: The SCIM method characterizes fast and slow diffusion more precisely compared to the independent voxel-wise IVIM model fitting in the liver and spleen. PMID:25832079
Benz, Matthias R; Bongartz, Georg; Froehlich, Johannes M; Winkel, David; Boll, Daniel T; Heye, Tobias
2018-07-01
The aim was to investigate the variation of the arterial input function (AIF) within and between various DCE MRI sequences. A dynamic flow-phantom and steady signal reference were scanned on a 3T MRI using fast low angle shot (FLASH) 2d, FLASH3d (parallel imaging factor (P) = P0, P2, P4), volumetric interpolated breath-hold examination (VIBE) (P = P0, P3, P2 × 2, P2 × 3, P3 × 2), golden-angle radial sparse parallel imaging (GRASP), and time-resolved imaging with stochastic trajectories (TWIST). Signal over time curves were normalized and quantitatively analyzed by full width half maximum (FWHM) measurements to assess variation within and between sequences. The coefficient of variation (CV) for the steady signal reference ranged from 0.07-0.8%. The non-accelerated gradient echo FLASH2d, FLASH3d, and VIBE sequences showed low within sequence variation with 2.1%, 1.0%, and 1.6%. The maximum FWHM CV was 3.2% for parallel imaging acceleration (VIBE P2 × 3), 2.7% for GRASP and 9.1% for TWIST. The FWHM CV between sequences ranged from 8.5-14.4% for most non-accelerated/accelerated gradient echo sequences except 6.2% for FLASH3d P0 and 0.3% for FLASH3d P2; GRASP FWHM CV was 9.9% versus 28% for TWIST. MRI acceleration techniques vary in reproducibility and quantification of the AIF. Incomplete coverage of the k-space with TWIST as a representative of view-sharing techniques showed the highest variation within sequences and might be less suited for reproducible quantification of the AIF. Copyright © 2018 Elsevier B.V. All rights reserved.
Gu, Hai Ting; Xie, Ping; Sang, Yan Fang; Wu, Zi Yi
2018-04-01
Abrupt change is an important manifestation of hydrological process with dramatic variation in the context of global climate change, the accurate recognition of which has great significance to understand hydrological process changes and carry out the actual hydrological and water resources works. The traditional method is not reliable at both ends of the samples. The results of the methods are often inconsistent. In order to solve the problem, we proposed a comprehensive weighted recognition method for hydrological abrupt change based on weighting by comparing of 12 commonly used methods for testing change points. The reliability of the method was verified by Monte Carlo statistical test. The results showed that the efficiency of the 12 methods was influenced by the factors including coefficient of variation (Cv), deviation coefficient (Cs) before the change point, mean value difference coefficient, Cv difference coefficient and Cs difference coefficient, but with no significant relationship with the mean value of the sequence. Based on the performance of each method, the weight of each test method was given following the results from statistical test. The sliding rank sum test method and the sliding run test method had the highest weight, whereas the RS test method had the lowest weight. By this means, the change points with the largest comprehensive weight could be selected as the final result when the results of the different methods were inconsistent. This method was used to analyze the daily maximum sequence of Jiajiu station in the lower reaches of the Lancang River (1-day, 3-day, 5-day, 7-day and 1-month). The results showed that each sequence had obvious jump variation in 2004, which was in agreement with the physical causes of hydrological process change and water conservancy construction. The rationality and reliability of the proposed method was verified.
Biologic variability of N-terminal pro-brain natriuretic peptide in adult healthy cats.
Harris, Autumn N; Estrada, Amara H; Gallagher, Alexander E; Winter, Brandy; Lamb, Kenneth E; Bohannon, Mary; Hanscom, Jancy; Mainville, Celine A
2017-02-01
Objectives The biologic variability of N-terminal pro-brain natriuretic peptide (NT-proBNP) and its impact on diagnostic utility is unknown in healthy cats and those with cardiac disease. The purpose of this study was to determine the biologic variation of NT-proBNP within-day and week-to-week in healthy adult cats. Methods Adult cats were prospectively evaluated by complete blood count (CBC), biochemistry, total thyroxine, echocardiography, electrocardiography and blood pressure, to exclude underlying systemic or cardiac disease. Adult healthy cats were enrolled and blood samples were obtained at 11 time points over a 6 week period (0, 2 h, 4 h, 6 h, 8 h, 10 h and at weeks 2, 3, 4, 5 and 6). The intra-individual (coefficient of variation [CV I ]) biologic variation along with index of individuality and reference change values (RCVs) were calculated. Univariate models were analyzed and included comparison of the six different time points for both daily and weekly samples. This was followed by a Tukey's post-hoc adjustment, with a P value of <0.05 being significant. Results The median daily and weekly CV I for the population were 13.1% (range 0-28.7%) and 21.2% (range 3.9-68.1%), respectively. The index of individuality was 0.99 and 1 for daily and weekly samples, respectively. The median daily and weekly RCVs for the population were 39.8% (range 17.0-80.5%) and 60.5% (range 20.1-187.8%), respectively. Conclusions and relevance This study demonstrates high individual variability for NT-proBNP concentrations in a population of adult healthy cats. Further research is warranted to evaluate NT-proBNP variability, particularly how serial measurements of NT-proBNP may be used in the diagnosis and management of cats with cardiac disease.
Physico-chemical characteristics of shallot New-Superior Varieties (NSV) from Indonesia
NASA Astrophysics Data System (ADS)
Sukasih, E.; Setyadjit; Musadad, D.
2018-01-01
Shallot is one of the priority agricultural commodities to be developed in Indonesia to reduce import and to stabilize domestic supply. The efforts include the selection of varieties, seed technology, agronomy, handling and processing to extend the supply and added value. Indonesian Agency for Agricultural Research and Development (IAARD) has purified, cross-pollinated, selected and released new varieties called New Superior Varieties (NSV) to farmers. The purpose of this research was to investigate the characteristic of fresh shallot NSV by understanding its potential for raw material of processed product. A completely randomized design (CRD) of single factor of ten local varieties of shallot such as Cv. Sembrani, Cv. Kuning, Cv. Pancasona, Cv. Bima, Cv. Trisula, Cv. Pikatan, Cv. Katumi, Cv. Kramat-2, Cv. Mentes and Cv. Majalok of three replication was used to arrange the experiment. The results showed that shallot New Superior Varieties (NSV) were significant by effect the physico-chemical parameters, such as diameter, length, weight of both in main bulb and tiller bulb, fat total, carbohydrate, crude fiber, starch content, antioxidant capacity and quercetin. Of the ten varieties of shallot characterized, the largest bulbs are Cv. Sembrani i.e 5.30 ± 0.3g per bulb, the best red color for shallot peeled was Cv. Kuning. Furthermore Cv. Pancasona have the highest protein content of 4.23 ± 0.2%, Cv. Mentes have the highest functional properties of quercetin 1766.4 ± 134 ppm. Shallot varieties such as Cv. Sembrani, Cv. Bima, Cv. Kuning and Cv. Trisula suitable for use as fresh product. Shallot varieties such as Cv. Pikatan, Cv. Pancasona, Cv. Katumi and Cv. Kramat-2 are suitable as raw materials for processed products. Cv. Mentes and Cv. Majalok were potential for raw materials of functional food and pharmaceutical industries.
Ashraf, Muhammad Arslan; Ashraf, Muhammad
2016-04-01
Hydroponic experiment was conducted to appraise variation in the salt tolerance potential of two wheat cultivars (salt tolerant, S-24, and moderately salt sensitive, MH-97) at different growth stages. These two wheat cultivars are not genetically related as evident from randomized polymorphic DNA analysis (random amplified polymorphic DNA (RAPD)) which revealed 28% genetic diversity. Salinity stress caused a marked reduction in grain yield of both wheat cultivars. However, cv. S-24 was superior to cv. MH-97 in maintaining grain yield under saline stress. Furthermore, salinity caused a significant variation in different physiological attributes measured at different growth stages. Salt stress caused considerable reduction in different water relation attributes of wheat plants. A significant reduction in leaf water, osmotic, and turgor potentials was recorded in both wheat cultivars at different growth stages. Maximal reduction in leaf water potential was recorded at the reproductive stage in both wheat cultivars. In contrast, maximal turgor potential was observed at the boot stage. Salt-induced adverse effects of salinity on different water relation attributes were more prominent in cv. MH-97 as compared to those in cv. S-24. Salt stress caused a substantial decrease in glycine betaine and alpha tocopherols. These biochemical attributes exhibited significant salt-induced variation at different growth stages in both wheat cultivars. For example, maximal accumulation of glycine betaine was evident at the early growth stages (vegetative and boot). However, cv. S-24 showed higher accumulation of this organic osmolyte, and this could be the reason for maintenance of higher turgor than that of cv. MH-97 under stress conditions. Salt stress significantly increased the endogenous levels of toxic ions (Na(+) and Cl(-)) and decreased essential cations (K(+) and Ca(2+)) in both wheat cultivars at different growth stages. Furthermore, K(+)/Na(+) and Ca(2+)/Na(+) ratios decreased markedly due to salt stress in both wheat cultivars at different growth stages, and this salt-induced reduction was more prominent in cv. MH-97. Moreover, higher K(+)/Na(+) and Ca(2+)/Na(+) ratios were recorded at early growth stages in both wheat cultivars. It can be inferred from the results that wheat plants are more prone to adverse effects of salinity stress at early growth stages than that at the reproductive stage.
Raisis, A L; Young, L E; Meire, H; Walsh, K; Taylor, P M; Lekeux, P
2000-05-01
The purpose of this study was to determine the repeatability of femoral blood flow recorded using Doppler ultrasound in anaesthetised horses. Doppler ultrasound of the femoral artery and vein was performed in 6 horses anaesthetised with halothane and positioned in left lateral recumbency. Velocity spectra, recorded using low pulse repetition frequency, were used to calculate time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb), volumetric flow, early diastolic deceleration slope (EDDS) and pulsatility index (PI). Within-patient variability was determined for sequential Doppler measurements recorded during a single standardised anaesthetic episode. Within-patient variability was also determined for Doppler and cardiovascular measurements recorded during 4 separate standardised anaesthetic episodes performed at intervals of at least one month. Within-patient variation during a single anaesthetic episode was small. Coefficients of variation (cv) were <12.5% for arterial measurements and <17% for venous measurements. Intraclass correlation coefficient was >0.75 for all measurements. No significant change was observed in measurements of cardiovascular function suggesting that within-patient variation observed during a single anaesthetic episode was due to measurement error. In contrast, within-patient variation during 4 separate anaesthetic episodes was marked (cv>17%) for most Doppler measurements obtained from arteries and veins. Variation in measurements of cardiovascular function were marked (cv>20%), suggesting that there is marked biological variation in central and peripheral observed. Further studies are warranted to determine the ability of this technique to detect differences in blood flow during administration of different anaesthetic agents.
Randall A. Kramer; D. Evan Mercer
1997-01-01
(CV) is the most common technique for valuing nonmarket environmental resources, rarely has it been applied to global environmental goods. This study uses CV in a national survey to assess the value U.S. residents place on tropical rain forest protection. On average, respondents were willing to make a one-time payment of approximately $21-31 per household to protect an...
Filimberti, E; Degl'Innocenti, S; Borsotti, M; Quercioli, M; Piomboni, P; Natali, I; Fino, M G; Caglieresi, C; Criscuoli, L; Gandini, L; Biggeri, A; Maggi, M; Baldi, E
2013-05-01
We report the results of the first three trials of an external quality control (EQC) programme performed in 71 laboratories executing semen analysis in Tuscany Region (Italy). At the end of the second trial, participants were invited to attend a teaching course illustrating and inviting to adhere to procedures recommended by WHO (V edition). Results of the first three trials of the EQC documented a huge variability in the procedures and the results. The highest variability was found for morphology (CV above 80% for all the trials), followed by count (CV of about 60% for all the trials) and motility (CV below 30% for all the trials). When results of sperm count and morphology were divided according to the used method, mean CV values did not show significant differences. CV for morphology dropped significantly at the third trial for most methods, indicating the usefulness of the teaching course for morphology assessment. Conversely, no differences were observed after the course for motility and for most methods to evaluate count, although CV values were lower at the second and third trial for the laboratories using the Burker cytometer. When results were divided according to tertiles of activity, the lowest mean bias values (difference between each laboratory result and the median value of the results) for count and morphology were observed for laboratories in the third tertile (performing over 200 semen analysis/year). Of interest, mean bias values for concentration dropped significantly at the third trial for low activity laboratories. In conclusion, lack of agreement of results of semen analysis in Tuscany is mainly because of the activity and the experience of the laboratory. Our study points out the importance of participating in EQC programmes and periodical teaching courses as well as the use of WHO recommended standardized procedures to increase precision and to allow the use of WHO reference values. © 2013 American Society of Andrology and European Academy of Andrology.
Peng, Yifeng; Tellier, Liane E; Temenoff, Johnna S
2016-08-16
Sustained release of anti-inflammatory agents remains challenging for small molecule drugs due to their low molecular weight and hydrophobicity. Therefore, the goal of this study was to control the release of a small molecule anti-inflammatory agent, crystal violet (CV), from hydrogels fabricated with heparin, a highly sulfated glycosaminoglycan capable of binding positively-charged molecules such as CV. In this system, both electrostatic interactions between heparin and CV and hydrogel degradation were tuned simultaneously by varying the level of heparin sulfation and varying the amount of dithiothreitol within hydrogels, respectively. It was found that heparin sulfation significantly affected CV release, whereby more sulfated heparin hydrogels (Hep and Hep(-N)) released CV with near zero-order release kinetics (R-squared values between 0.96-0.99). Furthermore, CV was released more quickly from fast-degrading hydrogels than slow-degrading hydrogels, providing a method to tune total CV release between 5-15 days while maintaining linear release kinetics. In particular, N-desulfated heparin hydrogels exhibited efficient CV loading (∼90% of originally included CV), near zero-order CV release kinetics, and maintenance of CV bioactivity after release, making this hydrogel formulation a promising CV delivery vehicle for a wide range of inflammatory diseases.
Spectral relative standard deviation: a practical benchmark in metabolomics.
Parsons, Helen M; Ekman, Drew R; Collette, Timothy W; Viant, Mark R
2009-03-01
Metabolomics datasets, by definition, comprise of measurements of large numbers of metabolites. Both technical (analytical) and biological factors will induce variation within these measurements that is not consistent across all metabolites. Consequently, criteria are required to assess the reproducibility of metabolomics datasets that are derived from all the detected metabolites. Here we calculate spectrum-wide relative standard deviations (RSDs; also termed coefficient of variation, CV) for ten metabolomics datasets, spanning a variety of sample types from mammals, fish, invertebrates and a cell line, and display them succinctly as boxplots. We demonstrate multiple applications of spectral RSDs for characterising technical as well as inter-individual biological variation: for optimising metabolite extractions, comparing analytical techniques, investigating matrix effects, and comparing biofluids and tissue extracts from single and multiple species for optimising experimental design. Technical variation within metabolomics datasets, recorded using one- and two-dimensional NMR and mass spectrometry, ranges from 1.6 to 20.6% (reported as the median spectral RSD). Inter-individual biological variation is typically larger, ranging from as low as 7.2% for tissue extracts from laboratory-housed rats to 58.4% for fish plasma. In addition, for some of the datasets we confirm that the spectral RSD values are largely invariant across different spectral processing methods, such as baseline correction, normalisation and binning resolution. In conclusion, we propose spectral RSDs and their median values contained herein as practical benchmarks for metabolomics studies.
Müller, Hans-Peter; Grön, Georg; Sprengelmeyer, Reiner; Kassubek, Jan; Ludolph, Albert C; Hobbs, Nicola; Cole, James; Roos, Raymund A C; Duerr, Alexandra; Tabrizi, Sarah J; Landwehrmeyer, G Bernhard; Süssmuth, Sigurd D
2013-01-01
Assessment of the feasibility to average diffusion tensor imaging (DTI) metrics of MRI data acquired in the course of a multicenter study. Sixty-one early stage Huntington's disease patients and forty healthy controls were studied using four different MR scanners at four European sites with acquisition protocols as close as possible to a given standard protocol. The potential and feasibility of averaging data acquired at different sites was evaluated quantitatively by region-of-interest (ROI) based statistical comparisons of coefficients of variation (CV) across centers, as well as by testing for significant group-by-center differences on averaged fractional anisotropy (FA) values between patients and controls. In addition, a whole-brain based statistical between-group comparison was performed using FA maps. The ex post facto statistical evaluation of CV and FA-values in a priori defined ROIs showed no differences between sites above chance indicating that data were not systematically biased by center specific factors. Averaging FA-maps from DTI data acquired at different study sites and different MR scanner types does not appear to be systematically biased. A suitable recipe for testing on the possibility to pool multicenter DTI data is provided to permit averaging of DTI-derived metrics to differentiate patients from healthy controls at a larger scale.
[Comparison among three translucency parameters].
Fang, Xiong; Hui, Xia
2017-06-01
This study aims to compare the three commonly used translucency parameters in prosthodontics: transmittance (T), contrast ratio (CR), and translucency parameter (TP). Six platelet specimens were composed of Vita enamel and dental porcelain. The initial thickness was 1.2 mm. The specimens were gradually ground to 1.0, 0.8, 0.6, 0.4, and 0.2 mm. T, color parameters, and reflection were measured by a spectrocolorimeter for each corresponding thickness. T, CR and TP were calculated and compared. TP increased, whereas CR decreased, with decreasing thickness. Moreover, T increased with decreasing thickness, and exponential relationships were found. Two-way ANOVA showed statistical significance between T and thickness, except between T and the 1.2 mm and 1.0 mm enamel porcelain groups. No difference was found among the coefficient variations (CV) of T, CR and TP. Curve fitting indicated the existence of exponential relationships between T and CR and between T and TP. The values for goodness of fit with statistical significance were 0.951 and 0.939, respectively (P<0.05). Under the experimental conditions, T, TP and CR achieved the same CV. T and TP, as well as T and CR, were found with exponential relationships. The value of CR and TP could not represent the translucency precisely, especially when comparing the changing ratios.
NASA Astrophysics Data System (ADS)
Cortesi, N.; Trigo, R.; González-Hidalgo, J. C.; Ramos, A.
2012-04-01
Precipitation over Iberian Peninsula (IP) presents large values of interannual variability and large spatial contrasts between wet mountainous regions in the north and dry regions in the southern plains. Unlike other European regions, IP was poorly monitored for precipitation during 19th century. Here we present a new approach to fill this gap. A set of 26 atmospheric circulation weather types (Trigo R.M. and DaCamara C.C., 2000) derived from a recent SLP dataset, the EMULATE (European and North Atlantic daily to multidecadal climate variability) Project, was used to reconstruct Iberian monthly precipitation from October to March during 1851-1947. Principal Component Regression Analysis was chosen to develop monthly precipitation reconstruction back to 1851 and calibrated over 1948-2003 period for 3030 monthly precipitation series of high-density homogenized MOPREDAS (Monthly Precipitation Database for Spain and Portugal) database. Validation was conducted over 1920-1947 at 15 key site locations. Results show high model performance for selected months, with a mean coefficient of variation (CV) around 0.6 during validation period. Lower CV values were achieved in western area of IP. Trigo, R. M., and DaCamara, C.C., 2000: "Circulation weather types and their impact on the precipitation regime in Portugal". Int. J. Climatol., 20, 1559-1581.
Hou, Xiyong; Li, Mingjie; Gao, Meng; Yu, Liangju; Bi, Xiaoli
2013-01-01
Annual normalized difference vegetation index (NDVI) and chlorophyll-a (Chl-a) concentration are the most important large-scale indicators of terrestrial and oceanic ecosystem net primary productivity. In this paper, the Sea-viewing Wide Field-of-view Sensor level 3 standard mapped image annual products from 1998 to 2009 are used to study the spatial-temporal characters of terrestrial NDVI and oceanic Chl-a concentration on two sides of the coastline of China by using the methods of mean value (M), coefficient of variation (CV), the slope of unary linear regression model (Slope), and the Hurst index (H). In detail, we researched and analyzed the spatial-temporal dynamics, the longitudinal zonality and latitudinal zonality, the direction, intensity, and persistency of historical changes. The results showed that: (1) spatial patterns of M and CV between NDVI and Chl-a concentration from 1998 to 2009 were very different. The dynamic variation of terrestrial NDVI was much mild, while the variation of oceanic Chl-a concentration was relatively much larger; (2) distinct longitudinal zonality was found for Chl-a concentration and NDVI due to their hypersensitivity to the distance to shoreline, and strong latitudinal zonality existed for Chl-a concentration while terrestrial NDVI had a very weak latitudinal zonality; (3) overall, the NDVI showed a slight decreasing trend while the Chl-a concentration showed a significant increasing trend in the past 12 years, and both of them exhibit strong self-similarity and long-range dependence which indicates opposite future trends between land and ocean.
Toth, Peter P; Danese, Mark; Villa, Guillermo; Qian, Yi; Beaubrun, Anne; Lira, Armando; Jansen, Jeroen P
2017-06-01
To estimate real-world cardiovascular disease (CVD) burden and value-based price range of evolocumab for a US-context, high-risk, secondary-prevention population. Burden of CVD was assessed using the UK-based Clinical Practice Research Datalink (CPRD) in order to capture complete CV burden including CV mortality. Patients on standard of care (SOC; high-intensity statins) in CPRD were selected based on eligibility criteria of FOURIER, a phase 3 CV outcomes trial of evolocumab, and categorized into four cohorts: high-risk prevalent atherosclerotic CVD (ASCVD) cohort (n = 1448), acute coronary syndrome (ACS) (n = 602), ischemic stroke (IS) (n = 151), and heart failure (HF) (n = 291) incident cohorts. The value-based price range for evolocumab was assessed using a previously published economic model. The model incorporated CPRD CV event rates and considered CV event reduction rate ratios per 1 mmol/L reduction in low-density lipoprotein-cholesterol (LDL-C) from a meta-analysis of statin trials by the Cholesterol Treatment Trialists Collaboration (CTTC), i.e. CTTC relationship. Multiple-event rates of composite CV events (ACS, IS, or coronary revascularization) per 100 patient-years were 12.3 for the high-risk prevalent ASCVD cohort, and 25.7, 13.3, and 23.3, respectively, for incident ACS, IS, and HF cohorts. Approximately one-half (42%) of the high-risk ASCVD patients with a new CV event during follow-up had a subsequent CV event. Combining these real-world event rates and the CTTC relationship in the economic model, the value-based price range (credible interval) under a willingness-to-pay threshold of $150,000/quality-adjusted life-year gained for evolocumab was $11,990 ($9,341-$14,833) to $16,856 ($12,903-$20,678) in ASCVD patients with baseline LDL-C levels ≥70 mg/dL and ≥100 mg/dL, respectively. Real-world CVD burden is substantial. Using the observed CVD burden in CPRD and the CTTC relationship, the cost-effectiveness analysis showed that, accounting for uncertainties, the expected value-based price for evolocumab is higher than its current annual cost, as long as the payer discount off list price is greater than 20%.
Hotfiel, Thilo; Heiss, Rafael; Janka, Rolf; Forst, Raimund; Raithel, Martine; Lutter, Christoph; Gelse, Kolja; Pachowsky, Milena; Golditz, Tobias
2018-06-09
The anterior talofibular ligament (ATFL) is the most frequently injured ligament during inversion strains of the ankle. The purpose of this study was to evaluate the feasibility of acoustic radiation force impulse (ARFI) elastography and to determine the in vivo mechanical properties of the ATFL in healthy athletes. Fifty-one healthy athletes (32 female, 28 male; 29 ±2 years) were recruited from the medical and sports faculty. ARFI values, represented as shear wave velocities (SWV) as well as conventional ultrasound were obtained for the ATFL in neutral ankle position. A clinical assessment was performed in which the American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot Score and the functional ankle ability measure (FAAM) were collected. Interobserver and intraobserver reliability (repeated sessions and repeated days) were assessed using an intra class correlation coefficient (ICC) and typical error (TE) calculation in absolute (TE) and relative units as coefficient of the variation (CV). SWV values of the ATFL had an average velocity of 1.79±0.34 m/s for all participants, with an average of 1.72±0.36 m/s for females and 1.85±0.31 m/s for males. The interobserver and intraobserver reliability revealed an ICC of 0.902 and 0.933 (TE of 0.67 (CV: 5.2 % and 0.51 m/s (CV: 3.83 %), respectively. FAAM and AOFAS revealed the best possible scores. ARFI seems to be a valuable diagnostic modality and represents a promising imaging marker for the assessment and monitoring of ankle ligaments in the context of acute and chronic ankle instabilities; ARFI could also be used to investigate loading or sport dependent adaptions.
Flatt, Andrew A; Hornikel, Bjoern; Esco, Michael R
2017-06-01
The purpose of this study was to evaluate cardiac-parasympathetic and psychometric responses to competition preparation in collegiate sprint-swimmers. Additionally, we aimed to determine the relationship between average vagal activity and its daily fluctuation during each training phase. Observational. Ten Division-1 collegiate sprint-swimmers performed heart rate variability recordings (i.e., log transformed root mean square of successive RR intervals, lnRMSSD) and completed a brief wellness questionnaire with a smartphone application daily after waking. Mean values for psychometrics and lnRMSSD (lnRMSSD mean ) as well as the coefficient of variation (lnRMSSD cv ) were calculated from 1 week of baseline (BL) followed by 2 weeks of overload (OL) and 2 weeks of tapering (TP) leading up to a championship competition. Competition preparation resulted in improved race times (p<0.01). Moderate decreases in lnRMSSD mean , and Large to Very Large increases in lnRMSSD cv , perceived fatigue and soreness were observed during the OL and returned to BL levels or peaked during TP (p<0.05). Inverse correlations between lnRMSSD mean and lnRMSSD cv were Very Large at BL and OL (p<0.05) but only Moderate at TP (p>0.05). OL training is associated with a reduction and greater daily fluctuation in vagal activity compared with BL, concurrent with decrements in perceived fatigue and muscle soreness. These effects are reversed during TP where these values returned to baseline or peaked leading into successful competition. The strong inverse relationship between average vagal activity and its daily fluctuation weakened during TP. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Dirnberger, Johannes; Wiesinger, Hans-Peter; Wiemer, Nicolas; Kösters, Alexander; Müller, Erich
2016-04-01
The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48-72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTD peak ) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0-30 to 0-300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTD peak (version II). High ICC-values (0.80-0.99) and acceptable CV-values (1.9-8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTD peak as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse 0-30ms and RTD/impulse 0-50ms ) showed clearly weaker reproducibility results (ICC: 0.53-0.84; CV: 7.3-16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTD peak -trial.
Kakite, Suguru; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Facciuto, Marcelo; Donnerhack, Claudia; Taouli, Bachir
2015-01-01
To evaluate short-term test-retest and interobserver reproducibility of IVIM (intravoxel incoherent motion) diffusion parameters and ADC (apparent diffusion coefficient) of hepatocellular carcinoma (HCC) and liver parenchyma at 3.0T. In this prospective Institutional Review Board (IRB)-approved study, 11 patients were scanned twice using a free-breathing single-shot echo-planar-imaging, diffusion-weighted imaging (DWI) sequence using 4 b values (b = 0, 50, 500, 1000 s/mm(2)) and IVIM DWI using 16 b values (0-800 s/mm(2)) at 3.0T. IVIM parameters (D: true diffusion coefficient, D*: pseudodiffusion coefficient, PF: perfusion fraction) and ADC (using 4 b and 16 b) were calculated. Short-term test-retest and interobserver reproducibility of IVIM parameters and ADC were assessed by measuring correlation coefficient, coefficient of variation (CV), and Bland-Altman limits of agreements (BA-LA). Fifteen HCCs were assessed in 10 patients. Reproducibility of IVIM metrics in HCC was poor for D* and PF (mean CV 60.6% and 37.3%, BA-LA: -161.6% to 135.3% and -66.2% to 101.0%, for D* and PF, respectively), good for D and ADC (CV 19.7% and <16%, BA-LA -57.4% to 36.3% and -38.2 to 34.1%, for D and ADC, respectively). Interobserver reproducibility was on the same order of test-retest reproducibility except for PF in HCC. Reproducibility of diffusion parameters was better in liver parenchyma compared to HCC. Poor reproducibility of D*/PF and good reproducibility for D/ADC were observed in HCC and liver parenchyma. These findings may have implications for trials using DWI in HCC. © 2014 Wiley Periodicals, Inc.
Bias in error estimation when using cross-validation for model selection.
Varma, Sudhir; Simon, Richard
2006-02-23
Cross-validation (CV) is an effective method for estimating the prediction error of a classifier. Some recent articles have proposed methods for optimizing classifiers by choosing classifier parameter values that minimize the CV error estimate. We have evaluated the validity of using the CV error estimate of the optimized classifier as an estimate of the true error expected on independent data. We used CV to optimize the classification parameters for two kinds of classifiers; Shrunken Centroids and Support Vector Machines (SVM). Random training datasets were created, with no difference in the distribution of the features between the two classes. Using these "null" datasets, we selected classifier parameter values that minimized the CV error estimate. 10-fold CV was used for Shrunken Centroids while Leave-One-Out-CV (LOOCV) was used for the SVM. Independent test data was created to estimate the true error. With "null" and "non null" (with differential expression between the classes) data, we also tested a nested CV procedure, where an inner CV loop is used to perform the tuning of the parameters while an outer CV is used to compute an estimate of the error. The CV error estimate for the classifier with the optimal parameters was found to be a substantially biased estimate of the true error that the classifier would incur on independent data. Even though there is no real difference between the two classes for the "null" datasets, the CV error estimate for the Shrunken Centroid with the optimal parameters was less than 30% on 18.5% of simulated training data-sets. For SVM with optimal parameters the estimated error rate was less than 30% on 38% of "null" data-sets. Performance of the optimized classifiers on the independent test set was no better than chance. The nested CV procedure reduces the bias considerably and gives an estimate of the error that is very close to that obtained on the independent testing set for both Shrunken Centroids and SVM classifiers for "null" and "non-null" data distributions. We show that using CV to compute an error estimate for a classifier that has itself been tuned using CV gives a significantly biased estimate of the true error. Proper use of CV for estimating true error of a classifier developed using a well defined algorithm requires that all steps of the algorithm, including classifier parameter tuning, be repeated in each CV loop. A nested CV procedure provides an almost unbiased estimate of the true error.
Missler, U; Gutekunst, R; Wood, W G
1994-03-01
Immunometric assays were developed for thyrotropin and thyroglobulin using time-resolved fluorescence as the measurement signal. The assays were suitable for measurements in serum/plasma or in dry blood spots (3 mm diameter). Both assays have acceptable coefficients of variation for dry blood spots (intra-assay median CV < 10%, interassay CV < 15%) in the concentration range of interest (thyrotropin 3-250 mU/l, thyroglobulin 10-500 micrograms/l). The relatively high CV values are not only due to the assay design but also the inhomogeneity of the samples used. For serum samples the median intra-assay CV was < 3% for thyrotropin in the range 0.1-50 mU/l and for thyroglobulin between 2 and 500 micrograms/l. The corresponding inter-assay CV were less than 5%. The assays were evaluated in field studies carried out under auspices of International Council for Control of Iodine Deficiency Disorders (ICCIDD) with the support of UNICEF in Algeria, Peru, India and Zimbabwe, and were found to be practical inasmuch as dry blood spot samples could be transported without special precautions for up to 5-6 weeks without significant loss in immunoreactivity. This agrees with other findings. The results showed that serum thyroglobulin levels are a more sensitive indicator of iodine deficiency than thyrotropin; elevated thyroglobulin levels were found in 182/304 children in Zimbabwe compared with elevated thyrotropin level in 28/304 cases. 213/304 children had enlarged thyroid glands. The cut-off levels used here were 4.5 mU/l thyrotropin and 20 micrograms/l for thyroglobulin, both in whole blood. The assays proved useful for assessing the efficacy of iodine therapy, either by oral dosage or intramuscularly (iodised oil).(ABSTRACT TRUNCATED AT 250 WORDS)
Urinalysis: The Automated Versus Manual Techniques; Is It Time To Change?.
Ahmed, Asmaa Ismail; Baz, Heba; Lotfy, Sarah
2016-01-01
Urinalysis is the third major test in clinical laboratory. Manual technique imprecision urges the need for a rapid reliable automated test. We evaluated the H800-FUSIOO automatic urine sediment analyzer and compared it to the manual urinalysis technique to determine if it may be a competitive substitute in laboratories of central hospitals. 1000 urine samples were examined by the two methods in parallel. Agreement, precision, carryover, drift, sensitivity, specificity, and practicability criteria were tested. Agreement ranged from excellent to good for all urine semi-quantitative components (K > 0.4, p = 0.000), except for granular casts (K = 0.317, p = 0.000). Specific gravity results correlated well between the two methods (r = 0.884, p = 0.000). RBCS and WBCs showed moderate correlation (r = 0.42, p = 0.000) and (r = 0.44, p = 0.000), respectively. The auto-analyzer's within-run precision was > 75% for all semi-quantitative components except for proteins (50% precision). This finding in addition to the granular casts poor agreement indicate the necessity of operator interference at the critical cutoff values. As regards quantitative contents, RBCs showed a mean of 69.8 +/- 3.95, C.V. = 5.7, WBCs showed a mean of 38.9 +/- 1.9, C.V. = 4.9). Specific gravity, pH, microalbumin, and creatinine also showed good precision results with C.Vs of 0.000, 2.6, 9.1, and 0.00 respectively. In the between run precision, positive control showed good precision (C.V. = 2.9), while negative control's C.V. was strikingly high (C.V. = 127). Carryover and drift studies were satisfactory. Manual examination of inter-observer results showed major discrepancies (< 60% similar readings), while intra-observer's results correlated well with each other (r = 0.99, p = 0.000). Automation of urinalysis decreases observer-associated variation and offers prompt competitive results when standardized for screening away from the borderline cutoffs.
Bircan, Cavit
2009-01-01
To determine differences in mean aflatoxin contamination and subsample variance from dry and slurry homogenizations, 10 kg of six different, naturally contaminated dried fig samples were collected from various exporting companies in accordance with the EU Commission Directive. The samples were first dry-mixed for 5 min using a blender and sub-sampled seven times; the remainder was slurry homogenized (1 : 1, v/v) and sub-sampled seven times. Aflatoxin B1 and total aflatoxin levels were recorded and coefficient of variations (CV) computed for all sub-samples. Only a small reduction in sub-sample variations, indicated by the lower CV values, and slight differences in mean aflatoxin B1 and total aflatoxin levels were observed when slurry homogenization was applied. Therefore, 7326 dried figs, destined for export from Turkey to the EU and collected during the 2008 crop year, were dry-homogenized and tested for aflatoxins (B1, B2, G1 and G2) by immunoaffinity column clean-up using RP-HPLC. While 34% of the samples contained detectable levels of total aflatoxins (0.20-208.75 µg kg(-1)), only 9% of them exceeded the EU limit of 4 µg kg(-1) in the range 2.0-208.75 µg kg(-1), respectively. A substantial increase in the incidence of aflatoxins was observed in 2008, most likely due to the drought stress experienced in Aydin province as occurred in 2007.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craciunescu, Oana I., E-mail: oana.craciunescu@duke.edu; Yoo, David S.; Cleland, Esi
2012-03-01
Purpose: Dynamic contrast-enhanced (DCE) MRI-extracted parameters measure tumor microvascular physiology and are usually calculated from an intratumor region of interest (ROI). Optimal ROI delineation is not established. The valid clinical use of DCE-MRI requires that the variation for any given parameter measured within a tumor be less than that observed between tumors in different patients. This work evaluates the impact of tumor ROI selection on the assessment of intra- and interpatient variability. Method and Materials: Head and neck cancer patients received initial targeted therapy (TT) treatment with erlotinib and/or bevacizumab, followed by radiotherapy and concurrent cisplatin with synchronous TT. DCE-MRImore » data from Baseline and the end of the TT regimen (Lead-In) were analyzed to generate the vascular transfer function (K{sup trans}), the extracellular volume fraction (v{sub e}), and the initial area under the concentration time curve (iAUC{sub 1min}). Four ROI sampling strategies were used: whole tumor or lymph node (Whole), the slice containing the most enhancing voxels (SliceMax), three slices centered in SliceMax (Partial), and the 5% most enhancing contiguous voxels within SliceMax (95Max). The average coefficient of variation (aCV) was calculated to establish intrapatient variability among ROI sets and interpatient variability for each ROI type. The average ratio between each intrapatient CV and the interpatient CV was calculated (aRCV). Results: Baseline primary/nodes aRCVs for different ROIs not including 95Max were, for all three MR parameters, in the range of 0.14-0.24, with Lead-In values between 0.09 and 0.2, meaning a low intrapatient vs. interpatient variation. For 95Max, intrapatient CVs approximated interpatient CVs, meaning similar data dispersion and higher aRCVs (0.6-1.27 for baseline) and 0.54-0.95 for Lead-In. Conclusion: Distinction between different patient's primary tumors and/or nodes cannot be made using 95Max ROIs. The other three strategies are viable and equivalent for using DCE-MRI to measure head and neck cancer physiology.« less
Electronic leaf wetness duration sensor: why it should be painted.
Sentelhas, P C; Monteiro, J E B A; Gillespie, T J
2004-05-01
The purpose of this study was to compare and evaluate the performance of electronic leaf wetness duration (LWD) sensors in measuring LWD in a cotton crop canopy when unpainted and painted sensors were used. LWD was measured with flat, printed-circuit wetness sensors, and the data were divided into two periods of 24 days: from 18 December 2001 to 10 January 2002, when the sensors were unpainted, and from 20 January to 13 February 2002, when the sensors were painted with white latex paint (two coats of paint). The data analysis included evaluating the coefficient of variation (CV%) among the six sensors for each day, and the relationship between the measured LWD (mean for the six sensors) and the number of hours with dew point depression under 2 degrees C, used as an indicator of dew presence. The results showed that the painting markedly reduced the CV% values. For the unpainted sensors the CV% was on average 67% against 9% for painted sensors. For the days without rainfall this reduction was greater. Comparing the sensor measurements to another estimator of LWD, in this case the number of hours with dew point depression under 2 degrees C, it was also observed that painting improved not only the precision of the sensors but also their sensitivity, because it increases the ability of the sensor to detect and measure the wetness promoted by small water droplets.
New validated method for piracetam HPLC determination in human plasma.
Curticapean, Augustin; Imre, Silvia
2007-01-10
The new method for HPLC determination of piracetam in human plasma was developed and validated by a new approach. The simple determination by UV detection was performed on supernatant, obtained from plasma, after proteins precipitation with perchloric acid. The chromatographic separation of piracetam under a gradient elution was achieved at room temperature with a RP-18 LiChroSpher 100 column and aqueous mobile phase containing acetonitrile and methanol. The quantitative determination of piracetam was performed at 200 nm with a lower limit of quantification LLQ=2 microg/ml. For this limit, the calculated values of the coefficient of variation and difference between mean and the nominal concentration are CV%=9.7 and bias%=0.9 for the intra-day assay, and CV%=19.1 and bias%=-7.45 for the between-days assay. For precision, the range was CV%=1.8/11.6 in the intra-day and between-days assay, and for accuracy, the range was bias%=2.3/14.9 in the intra-day and between-days assay. In addition, the stability of piracetam in different conditions was verified. Piracetam proved to be stable in plasma during 4 weeks at -20 degrees C and for 36 h at 20 degrees C in the supernatant after protein precipitation. The new proposed method was used for a bioequivalence study of two medicines containing 800 mg piracetam.
Claus, C; Bergs, S; Emmrich, N C; Hübschen, J M; Mankertz, A; Liebert, U G
2017-02-01
Although teratogenic rubella virus (RV) causes a vaccine-preventable disease, it is still endemic in several countries worldwide. Thus, there is a constant risk of RV importation into non-endemic areas. RV monitoring, especially during measles and Zika virus outbreaks, requires reliable diagnostic tools. For this study, a TaqMan-based one-step reverse transcription-quantitative PCR (RT-qPCR) assay, with the p90 gene as a novel and so far unexplored target for detection of clade I and II genotypes, was developed and evaluated. Automated nucleic acid extraction was carried out. Performance characteristics of the TaqMan RT-qPCR assay were determined for a RV plasmid standard and RNA extracted from virus-infected cell culture supernatants representing clade I and II genotypes. Diagnostic specificity and sensitivity were validated against other RNA and DNA viruses, relevant for RV diagnostic approaches and for RV-positive clinical samples, respectively. The assay is specific and highly sensitive with a limit of detection as low as five to one copies per reaction or 200 infectious virus particles per ml. The coefficients of variation (CV) were specified as intra- (within one run) and inter- (between different runs) assay variation, and calculated based on the standard deviations for the obtained Ct values of the respective samples. Intra- and inter-assay CV values were low, with a maximum of 3.4% and 2.4%, respectively. The assay was shown to be suitable and specific for the analysis of clinical samples. With p90 as a novel target, the highly sensitive and specific TaqMan assay outlined in this study is suitable for RV diagnosis worldwide.
López-Miguel, Alberto; Calabuig-Goena, María; Marqués-Fernández, Victoria; Fernández, Itziar; Alió, Jorge L; Maldonado, Miguel J
2016-11-04
To assess the reliability of corneal epithelial thickness (CET), nonepithelial central corneal thickness (NECCT), and central corneal thickness (CCT) measurements using Cirrus high-definition optical coherence tomography (HD-OCT) in patients who did and did not undergo cataract surgery. Forty patients who underwent uneventful phacoemulsification and 40 healthy participants were recruited to evaluate the intraobserver repeatability and interobserver reproducibility of CET, NECCT, and CCT measurements using Cirrus HD-OCT. To analyze repeatability, one examiner obtained 5 consecutive scans in each participant; for interobserver reproducibility, another examiner randomly obtained another scan. Within-subject standard deviation, coefficient of variation (CV), limits of agreement, and intraclass correlation coefficient (ICC) data were obtained. For intraobserver repeatability, the intrasession CV (CVw) and ICC values of the CET in the operated and nonoperated groups were 3.7% and 0.80 and 3.8% and 0.73, respectively; for NECCT, 0.7% and 0.98 and 0.8% and 0.97; and for CCT, 0.6% and 0.99 and 0.7% and 0.98. For interobserver reproducibility, the CVw and ICC values for the CET in the operated and nonoperated groups were 2.6% and 0.82 and 2.3% and 0.62, respectively; for NECCT, 0.7% and 0.98 and 0.5% and 0.98; and for CCT, 0.5% and 0.99 and 0.4% and 0.99. The corneal sublayer thickness can be measured reliably using Cirrus HD-OCT in patients who underwent cataract surgery and elderly participants; however, the CET consistency is poorer than the NECCT. Corneal epithelial thickness modifications exceeding 4% reflect true thickness changes instead of random error variations using HD-OCT.
NASA Astrophysics Data System (ADS)
Swami, D.; Parthasarathy, D.; Dave, P.
2016-12-01
Climate variability (CV) has adverse impact on crop production and inadequate research carried out to assess the impact of CV on crop production has aggravated the ability of farmers to adapt (Jones et al., 2000). A better understanding of CV is required to reduce the vulnerability of farmers towards existing and future CV. Further, a wide variation in policies related to climate change exists at global level and considering the state/nation as a single unit for policy formulations may lead to under-representation of regional problems. Hence, the present work chooses to focus on CVassessment at the regional/district level of Maharashtra state in India. Here, interannual variability of wet and dry spells from year 1951-2013, are used as a measure of CV. Statistical declining trend of wet spells for (12/34) districts was observed across all the districts of Maharashtra. Districts showing highest change in wet spell pre and post 1976/77 are Beed, Latur and Osmanabad belong to Central Maharashtra Plateau zone and Western Maharashtra scarcity zone. Dry spells for (8/34) districts were found to statistically increase across all the districts of Maharashtra. Washim, Yavatmal of Vidarbha zone; and Latur, Parbhani of Amravati division belonging to Central Maharashtra Plateau zone and Central Vidarbha zone are found to reflect the large variation in their behavior pre and post 1976/77. Findings reveal that districts from the same agro-climate zones respond differently to CV, indicating significant spatial heterogeneity within the region. Trend in monsoon variability was found to be prominent after 1976/77, suggesting an enhanced role of climate change on climate variability after 1977. It necessitates separate policy formulation related to CV and agriculture for each district to bring out the solution for regional issues (socio-political, farmers, agriculturalists, economical) more clearly. Further we have attempted to link agriculture vulnerability and crop sensitivity to CV. Results signify spatial and temporal variability of different agro-ecological and climate parameters; suitable adaptation measures to famers and policy makers need to address this change. The findings can be utilized by farmers and policy makers while formulating agricultural policies and adaptation measures related to climate change.
Variation in nutrients formulated and nutrients supplied on 5 California dairies.
Rossow, H A; Aly, S S
2013-01-01
Computer models used in ration formulation assume that nutrients supplied by a ration formulation are the same as the nutrients presented in front of the cow in the final ration. Deviations in nutrients due to feed management effects such as dry matter changes (i.e., rain), loading, mixing, and delivery errors are assumed to not affect delivery of nutrients to the cow and her resulting milk production. To estimate how feed management affects nutrients supplied to the cow and milk production, and determine if nutrients can serve as indexes of feed management practices, weekly total mixed ration samples were collected and analyzed for 4 pens (close-up cows, fresh cows, high-milk-producing, and low-milk-producing cows, if available) for 7 to 12 wk on 5 commercial California dairies. Differences among nutrient analyses from these samples and nutrients from the formulated rations were analyzed by PROC MIXED of SAS (SAS Institute Inc., Cary, NC). Milk fat and milk protein percentages did not vary as much [coefficient of variation (CV) = 18 to 33%] as milk yield (kg; CV = 16 to 47 %) across all dairies and pens. Variability in nutrients delivered were highest for macronutrient fat (CV = 22%), lignin (CV = 15%), and ash (CV = 11%) percentages and micronutrients Fe (mg/kg; CV = 48%), Na (%; CV = 42%), and Zn (mg/kg; CV = 38%) for the milking pens across all dairies. Partitioning of the variability in random effects of nutrients delivered and intraclass correlation coefficients showed that variability in lignin percentage of TMR had the highest correlation with variability in milk yield and milk fat percentage, followed by fat and crude protein percentages. But, variability in ash, fat, and lignin percentages of total mixed ration had the highest correlation with variability in milk protein percentage. Therefore, lignin, fat, and ash may be the best indices of feed management to include effects of variability in nutrients on variability in milk yield, milk fat, and milk protein percentages in ration formulation models. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Statistical power analysis of cardiovascular safety pharmacology studies in conscious rats.
Bhatt, Siddhartha; Li, Dingzhou; Flynn, Declan; Wisialowski, Todd; Hemkens, Michelle; Steidl-Nichols, Jill
2016-01-01
Cardiovascular (CV) toxicity and related attrition are a major challenge for novel therapeutic entities and identifying CV liability early is critical for effective derisking. CV safety pharmacology studies in rats are a valuable tool for early investigation of CV risk. Thorough understanding of data analysis techniques and statistical power of these studies is currently lacking and is imperative for enabling sound decision-making. Data from 24 crossover and 12 parallel design CV telemetry rat studies were used for statistical power calculations. Average values of telemetry parameters (heart rate, blood pressure, body temperature, and activity) were logged every 60s (from 1h predose to 24h post-dose) and reduced to 15min mean values. These data were subsequently binned into super intervals for statistical analysis. A repeated measure analysis of variance was used for statistical analysis of crossover studies and a repeated measure analysis of covariance was used for parallel studies. Statistical power analysis was performed to generate power curves and establish relationships between detectable CV (blood pressure and heart rate) changes and statistical power. Additionally, data from a crossover CV study with phentolamine at 4, 20 and 100mg/kg are reported as a representative example of data analysis methods. Phentolamine produced a CV profile characteristic of alpha adrenergic receptor antagonism, evidenced by a dose-dependent decrease in blood pressure and reflex tachycardia. Detectable blood pressure changes at 80% statistical power for crossover studies (n=8) were 4-5mmHg. For parallel studies (n=8), detectable changes at 80% power were 6-7mmHg. Detectable heart rate changes for both study designs were 20-22bpm. Based on our results, the conscious rat CV model is a sensitive tool to detect and mitigate CV risk in early safety studies. Furthermore, these results will enable informed selection of appropriate models and study design for early stage CV studies. Copyright © 2016 Elsevier Inc. All rights reserved.
Novel edible oil sources: Microwave heating and chemical properties.
Hashemi, Seyed Mohammad Bagher; Mousavi Khaneghah, Amin; Koubaa, Mohamed; Lopez-Cervantes, Jaime; Yousefabad, Seyed Hossein Asadi; Hosseini, Seyedeh Fatemeh; Karimi, Masoumeh; Motazedian, Azam; Asadifard, Samira
2017-02-01
The aim of this work was to investigate the effect of various microwave heating times (1, 3, 5, 10, and 15min) on the chemical properties of novel edible oil sources, including Mashhadi melon (Cucumis melo var. Iranians cv. Mashhadi), Iranian watermelon (Citrullus lanatus cv. Fire Fon), pumpkin (Cucurbita pepo subsp. pepo var. Styriaca), and yellow apple (Malus domestica cv. Golden Delicious) seed oils. The evaluated parameters were peroxide value (PV), conjugated diene (CD) and triene (CT) values, carbonyl value (CV), p-anisidine value (AnV), oil stability index (OSI), radical scavenging activity (RSA), total tocopherols, total phenolics, as well as chlorophyll and carotenoid contents. Results showed that extended microwave heating involves decreased quality of the seed oils, mainly due to the formation of primary and secondary oxidation products. Microwave heating time also affects the total contents of chlorophylls, carotenoids, phenolics and tocopherols, which clearly decrease by increasing the exposure time. The order of oxidative stability of the analyzed edible oils was pumpkin>Mashhadi melon>Iranian watermelon>yellow apple. The obtained results demonstrated the promising potential of these novel edible oils for different food applications. Copyright © 2016 Elsevier Ltd. All rights reserved.
Liu, Ruimin; Men, Cong; Yu, Wenwen; Xu, Fei; Wang, Qingrui; Shen, Zhenyao
2018-01-01
To examine the variabilities of source contributions in the Yangtze River Estuary (YRE), the uncertainty based on the positive matrix factorization (PMF) was applied to the source apportionment of the 16 priority PAHs in 120 surface sediment samples from four seasons. Based on the signal-to-noise ratios, the PAHs categorized as "Bad" might drop out of the estimation of bootstrap. Next, the spatial variability of residuals was applied to determine which species with non-normal curves should be excluded. The median values from the bootstrapped solutions were chosen as the best estimate of the true factor contributions, and the intervals from 5th to 95th percentile represent the variability in each sample factor contribution. Based on the results, the median factor contributions of wood grass combustion and coke plant emissions were highly correlated with the variability (R 2 = 0.6797-0.9937) in every season. Meanwhile, the factor of coal and gasoline combustion had large variability with lower R 2 values in every season, especially in summer (0.4784) and winter (0.2785). The coefficient of variation (CV) values based on the Bootstrap (BS) simulations were applied to indicate the uncertainties of PAHs in every factor of each season. Acy, NaP and BgP always showed higher CV values, which suggested higher uncertainties in the BS simulations, and the PAH with the lowest concentration among all PAHs usually became the species with higher uncertainties. Copyright © 2017 Elsevier Ltd. All rights reserved.
Duvnjak, L; Tomić, M; Blaslov, K; Vučković Rebrina, S
2016-06-01
To determine whether cardiac autonomic dysfunction represents a risk factor for diabetic retinopathy (DR) development and progression in persons with type 1 diabetes mellitus (T1DM). The study comprised 154 normoalbuminuric persons with T1DM divided into two groups according to the DR presence: with and without DR. Cardiovascular autonomic functioning was measured at baseline using conventional and spectral analysis. Participants were re-examined for the DR presence 18months after. The group with DR had longer disease duration compared to the group without DR (20 vrs 11.5years, p<0.001), heart rate coefficient of variation (HRV-CV) at rest and during deep breathing were lower in participants with DR (p=0.001 and 0.004), as well did spectral indices of HRV: low frequency (LF) band, high frequency (HF) band (p=0.003 and 0.022) while LF/HF ratio indicating sympathovagal balance was higher (p=0.037). No difference in glycaemic control or blood pressure value were observed. Twenty-one (13.36%) participants developed non proliferative DR or progressed to proliferative DR. Cox proportional regression showed that the 18months risk from retinal deterioration was reduced by 33.4% by each increase in the HRV-CV of 1%, 12.7% for the same HRV-CV increase during deep breathing while LF band of 1ms(2) results in 8.6% risk reduction. This study provides evidence that DR should not be considered merely a metabolic control manifestation and that HRV-CV as well as spectral indices of HRV might serve as a practical tool to identify a subgroup of T1DM patients with higher risk of retinal deterioration. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Buchanan, Diana Taibi; Landis, Carol A; Hohensee, Chancellor; Guthrie, Katherine A; Otte, Julie L; Paudel, Misti; Anderson, Garnet L; Caan, Bette; Freeman, Ellen W; Joffe, Hadine; LaCroix, Andrea Z; Newton, Katherine M; Reed, Susan D; Ensrud, Kristine E
2017-01-15
To determine effects of yoga and aerobic exercise compared with usual activity on objective assessments of sleep in midlife women. Secondary analyses of a randomized controlled trial in the Menopause Strategies: Finding Lasting Answers for Symptoms and Health (MsFLASH) network conducted among 186 late transition and postmenopausal women aged 40-62 y with hot flashes. Women were randomized to 12 w of yoga, supervised aerobic exercise, or usual activity. The mean and coefficient of variation (CV) of change in actigraph sleep measures from each intervention group were compared to the usual activity group using linear regression models. Baseline values of the primary sleep measures for the entire sample were mean total sleep time (TST) = 407.5 ± 56.7 min; mean wake after sleep onset (WASO) = 54.6 ± 21.8 min; mean CV for WASO = 37.7 ± 18.7 and mean CV for number of long awakenings > 5 min = 81.5 ± 46.9. Changes in the actigraphic sleep outcomes from baseline to weeks 11-12 were small, and none differed between groups. In an exploratory analysis, women with baseline Pittsburgh Sleep Quality Index higher than 8 had significantly reduced TST-CV following yoga compared with usual activity. This study adds to the currently scant literature on objective sleep outcomes from yoga and aerobic exercise interventions for this population. Although small effects on self-reported sleep quality were previously reported, the interventions had no statistically significant effects on actigraph measures, except for potentially improved sleep stability with yoga in women with poor self-reported sleep quality. © 2017 American Academy of Sleep Medicine
The first mass and angular momentum loss measurements for a CV-like binary
NASA Astrophysics Data System (ADS)
Drake, Jeremy
2015-10-01
The period distribution of close binaries, cataclysmic variables, novae and single-degenerate SN1a progenitor candidates is largely controlled by magnetically-driven mass and angular momentum loss (AML) from the M dwarf secondary. The mass loss rates for these spun-up stars remain essentially unknown and impossible to observe directly, with likely values in the range 1e-12 to 1e-15 Msun/yr. AML presciptions for CVs differ by orders of magnitude. One way to measure the mass loss rate is to observe the dM wind accrete onto its WD companion in a pre-CV very close to Roche Lobe overflow but lacking the obscuring complications and emission from an accretion disk. The measurement can be combined with realistic MHD models to understand the accretion fraction, the mass that escapes, and the AML. The best-studied nearby pre-CV is QS Vir (48pc, P=3.6hr). However, its wind accretion rates measured from 1999 HST UV spectra of the WD metal absorption lines and 2006 XMM-Newton CCD spectroscopy differ by a factor of a thousand, pointing to either a dominant CME stochastic component, or a magnetic switch found in MHD simulations and driven by cyclic activity on the M dwarf. HST COS spectra combined with XMM-Newton monitoring on timescales from weeks to years will tease out CME vs cyclic accretion variations. UV and X-ray measurements will provide the first consistency check of both accretion rate measurement methods. MHD models tailored to the system will enable the first quasi-direct measurements of the mass loss and AML from a CV-like binary. Our project requires 6 HST/COS orbits in Cycles 22-24, and 60ksec on XMM in Cycle 22
The first mass and angular momentum loss measurements for a CV-like binary
NASA Astrophysics Data System (ADS)
Drake, Jeremy
2014-10-01
The period distribution of close binaries, cataclysmic variables, novae and single-degenerate SN1a progenitor candidates is largely controlled by magnetically-driven mass and angular momentum loss (AML) from the M dwarf secondary. The mass loss rates for these spun-up stars remain essentially unknown and impossible to observe directly, with likely values in the range 1e-12 to 1e-15 Msun/yr. AML presciptions for CVs differ by orders of magnitude. One way to measure the mass loss rate is to observe the dM wind accrete onto its WD companion in a pre-CV very close to Roche Lobe overflow but lacking the obscuring complications and emission from an accretion disk. The measurement can be combined with realistic MHD models to understand the accretion fraction, the mass that escapes, and the AML. The best-studied nearby pre-CV is QS Vir (48pc, P=3.6hr). However, its wind accretion rates measured from 1999 HST UV spectra of the WD metal absorption lines and 2006 XMM-Newton CCD spectroscopy differ by a factor of a thousand, pointing to either a dominant CME stochastic component, or a "magnetic switch" found in MHD simulations and driven by cyclic activity on the M dwarf. HST COS spectra combined with XMM-Newton monitoring on timescales from weeks to years will tease out CME vs cyclic accretion variations. UV and X-ray measurements will provide the first consistency check of both accretion rate measurement methods. MHD models tailored to the system will enable the first quasi-direct measurements of the mass loss and AML from a CV-like binary. Our project requires 6 HST/COS orbits in Cycles 22-24, and 60ksec on XMM in Cycle 22
The first mass and angular momentum loss measurements for a CV-like binary
NASA Astrophysics Data System (ADS)
Drake, Jeremy
2016-10-01
The period distribution of close binaries, cataclysmic variables, novae and single-degenerate SN1a progenitor candidates is largely controlled by magnetically-driven mass and angular momentum loss (AML) from the M dwarf secondary. The mass loss rates for these spun-up stars remain essentially unknown and impossible to observe directly, with likely values in the range 1e-12 to 1e-15 Msun/yr. AML presciptions for CVs differ by orders of magnitude. One way to measure the mass loss rate is to observe the dM wind accrete onto its WD companion in a pre-CV very close to Roche Lobe overflow but lacking the obscuring complications and emission from an accretion disk. The measurement can be combined with realistic MHD models to understand the accretion fraction, the mass that escapes, and the AML. The best-studied nearby pre-CV is QS Vir (48pc, P=3.6hr). However, its wind accretion rates measured from 1999 HST UV spectra of the WD metal absorption lines and 2006 XMM-Newton CCD spectroscopy differ by a factor of a thousand, pointing to either a dominant CME stochastic component, or a magnetic switch found in MHD simulations and driven by cyclic activity on the M dwarf. HST COS spectra combined with XMM-Newton monitoring on timescales from weeks to years will tease out CME vs cyclic accretion variations. UV and X-ray measurements will provide the first consistency check of both accretion rate measurement methods. MHD models tailored to the system will enable the first quasi-direct measurements of the mass loss and AML from a CV-like binary. Our project requires 6 HST/COS orbits in Cycles 22-24, and 60ksec on XMM in Cycle 22
Yokoi, Masako; Hattori, Koji; Narikawa, Koichi; Ohgushi, Hajime; Tadokoro, Mika; Hoshi, Kazuto; Takato, Tsuyoshi; Myoui, Akira; Nanno, Katsuhiko; Kato, Yukio; Kanawa, Masami; Sugawara, Katsura; Kobo, Tomoko; Ushida, Takashi
2012-07-01
Tissue-engineered medical products (TEMPs) should be evaluated before implantation. Therefore, it is indispensable to establish evaluation protocols in regenerative medicine. Whether or not such evaluation protocols are reasonable is generally verified through a 'round robin' test. However, the round robin test for TEMPs intrinsically includes a deficiency, because 'identical' specimens can not be prepared for TEMPs. The aim of the study was to assess the feasibility and limitations of the round robin test for TEMPs by using a prepared evaluation protocol. We adopted tissue-engineered cartilage constructs as delivered specimens and a protocol of measuring sGAG content as an evaluation protocol proposed to ISO TC150/SC7, which is an invasive, but usually applied, method, although non-invasive methods are keenly required in evaluating TEMPs. The results showed that: (a) the coefficient of variation (CV) of the measured sGAG contents in intralaboratory tests was ~5% at most; (b) the CV of sGAG content in the scheme where each participating laboratory measured different constructs was comparable with that in the scheme where each participating laboratory measured one half of a construct along with the organizing laboratory; (c) the CV caused by factors other than the specimen was ~15%, comparable to that in reproducible experiments in biomedical fields. Based on these results, the study concludes that a round robin test for a TEMP could be valuable, under the condition that the delivered TEMPs are sufficiently reproducible so that the CV of the measured values is < 5% in the organizing laboratory. Copyright © 2011 John Wiley & Sons, Ltd.
[Habitat factor analysis for Torreya grandis cv. Merrillii based on spatial information technology].
Wang, Xiao-ming; Wang, Ke; Ao, Wei-jiu; Deng, Jin-song; Han, Ning; Zhu, Xiao-yun
2008-11-01
Torreya grandis cv. Merrillii, a tertiary survival plant, is a rare tree species of significant economic value and expands rapidly in China. Its special habitat factor analysis has the potential value to provide guide information for its planting, management, and sustainable development, because the suitable growth conditions for this tree species are special and strict. In this paper, the special habitat factors for T. grandis cv. Merrillii in its core region, i.e., in seven villages of Zhuji City, Zhejiang Province were analyzed with Principal Component Analysis (PCA) and a series of data, such as IKONOS image, Digital Elevation Model (DEM), and field survey data supported by the spatial information technology. The results showed that T. grandis cv. Merrillii exhibited high selectivity of environmental factors such as elevation, slope, and aspect. 96.22% of T. grandis cv. Merrillii trees were located at the elevation from 300 to 600 m, 97.52% of them were found to present on the areas whose slope was less than 300, and 74.43% of them distributed on sunny and half-sunny slopes. The results of PCA analysis indicated that the main environmental factors affecting the habitat of T. grandis cv. Merrillii were moisture, heat, and soil nutrients, and moisture might be one of the most important ecological factors for T. grandis cv. Merrillii due to the unique biological and ecological characteristics of the tree species.
Rayar, Michel; Tron, Camille; Jézéquel, Caroline; Beaurepaire, Jean Marie; Petitcollin, Antoine; Houssel-Debry, Pauline; Camus, Christophe; Verdier, Marie Clémence; Dehlawi, Ammar; Lakéhal, Mohamed; Desfourneaux, Véronique; Meunier, Bernard; Sulpice, Laurent; Bellissant, Eric; Boudjema, Karim; Lemaitre, Florian
2018-03-01
Tacrolimus (TAC) is the cornerstone of immunosuppressive regimen in liver transplantation (LT). Its pharmacokinetics is characterized by a high interpatient and intrapatient variability (IPV) leading to an unpredictable dose-response relationship. The aim of our study was to evaluate the impact of TAC IPV (IPV) on graft and patient outcomes after LT. We retrospectively analyzed 812 LT recipients treated with TAC. The IPV of TAC concentrations was estimated by calculating the coefficient of variation (CV) of whole blood trough concentrations. Patients were categorized in 2 groups: low IPV (CV < 40%) and high IPV (CV ≥ 40%). There were significantly more neurologic complications (31.2% vs 16.6%, P < 0.001), cardiovascular complications (19.7% vs 9.7%, P < 0.001), and acute renal failure requiring dialysis (8.5% vs 2.2%, P < 0.001) in the high CV group than in the low CV group. Moreover, graft survival was significantly poorer in the high CV group (hazard ratio, 1.42; 95% confidence interval, 1.04-1.95; P = 0.03). A pretransplantation elevated Model for End-Stage Liver Disease score (P < 0.001) and Child-Pugh grade (P < 0.001) were identified as risk factors for presenting a high CV. A high CV of TAC concentrations was found to be predictive of TAC-related toxicity and poorer survival.
Tipirneni-Sajja, Aaryani; Krafft, Axel J; McCarville, M Beth; Loeffler, Ralf B; Song, Ruitian; Hankins, Jane S; Hillenbrand, Claudia M
2017-07-01
The objective of this study is to evaluate radial free-breathing (FB) multiecho ultrashort TE (UTE) imaging as an alternative to Cartesian FB multiecho gradient-recalled echo (GRE) imaging for quantitative assessment of hepatic iron content (HIC) in sedated patients and subjects unable to perform breath-hold (BH) maneuvers. FB multiecho GRE imaging and FB multiecho UTE imaging were conducted for 46 test group patients with iron overload who could not complete BH maneuvers (38 patients were sedated, and eight were not sedated) and 16 control patients who could complete BH maneuvers. Control patients also underwent standard BH multiecho GRE imaging. Quantitative R2* maps were calculated, and mean liver R2* values and coefficients of variation (CVs) for different acquisitions and patient groups were compared using statistical analysis. FB multiecho GRE images displayed motion artifacts and significantly lower R2* values, compared with standard BH multiecho GRE images and FB multiecho UTE images in the control cohort and FB multiecho UTE images in the test cohort. In contrast, FB multiecho UTE images produced artifact-free R2* maps, and mean R2* values were not significantly different from those measured by BH multiecho GRE imaging. Motion artifacts on FB multiecho GRE images resulted in an R2* CV that was approximately twofold higher than the R2* CV from BH multiecho GRE imaging and FB multiecho UTE imaging. The R2* CV was relatively constant over the range of R2* values for FB multiecho UTE, but it increased with increases in R2* for FB multiecho GRE imaging, reflecting that motion artifacts had a stronger impact on R2* estimation with increasing iron burden. FB multiecho UTE imaging was less motion sensitive because of radial sampling, produced excellent image quality, and yielded accurate R2* estimates within the same acquisition time used for multiaveraged FB multiecho GRE imaging. Thus, FB multiecho UTE imaging is a viable alternative for accurate HIC assessment in sedated children and patients who cannot complete BH maneuvers.
Dołowy, Małgorzata; Kulpińska-Kucia, Katarzyna; Pyka, Alina
2014-01-01
A new specific, precise, accurate, and robust TLC-densitometry has been developed for the simultaneous determination of hydrocortisone acetate and lidocaine hydrochloride in combined pharmaceutical formulation. The chromatographic analysis was carried out using a mobile phase consisting of chloroform + acetone + ammonia (25%) in volume composition 8 : 2 : 0.1 and silica gel 60F254 plates. Densitometric detection was performed in UV at wavelengths 200 nm and 250 nm, respectively, for lidocaine hydrochloride and hydrocortisone acetate. The validation of the proposed method was performed in terms of specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and robustness. The applied TLC procedure is linear in hydrocortisone acetate concentration range of 3.75 ÷ 12.50 μg·spot−1, and from 1.00 ÷ 2.50 μg·spot−1 for lidocaine hydrochloride. The developed method was found to be accurate (the value of the coefficient of variation CV [%] is less than 3%), precise (CV [%] is less than 2%), specific, and robust. LOQ of hydrocortisone acetate is 0.198 μg·spot−1 and LOD is 0.066 μg·spot−1. LOQ and LOD values for lidocaine hydrochloride are 0.270 and 0.090 μg·spot−1, respectively. The assay value of both bioactive substances is consistent with the limits recommended by Pharmacopoeia. PMID:24526880
Dołowy, Małgorzata; Kulpińska-Kucia, Katarzyna; Pyka, Alina
2014-01-01
A new specific, precise, accurate, and robust TLC-densitometry has been developed for the simultaneous determination of hydrocortisone acetate and lidocaine hydrochloride in combined pharmaceutical formulation. The chromatographic analysis was carried out using a mobile phase consisting of chloroform+acetone+ammonia (25%) in volume composition 8:2:0.1 and silica gel 60F254 plates. Densitometric detection was performed in UV at wavelengths 200 nm and 250 nm, respectively, for lidocaine hydrochloride and hydrocortisone acetate. The validation of the proposed method was performed in terms of specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and robustness. The applied TLC procedure is linear in hydrocortisone acetate concentration range of 3.75÷12.50 μg·spot(-1), and from 1.00÷2.50 μg·spot(-1) for lidocaine hydrochloride. The developed method was found to be accurate (the value of the coefficient of variation CV [%] is less than 3%), precise (CV [%] is less than 2%), specific, and robust. LOQ of hydrocortisone acetate is 0.198 μg·spot(-1) and LOD is 0.066 μg·spot(-1). LOQ and LOD values for lidocaine hydrochloride are 0.270 and 0.090 μg·spot(-1), respectively. The assay value of both bioactive substances is consistent with the limits recommended by Pharmacopoeia.
Baad-Hansen, L; Pigg, M; Yang, G; List, T; Svensson, P; Drangsholt, M
2015-02-01
The reliability of comprehensive intra-oral quantitative sensory testing (QST) protocol has not been examined systematically in patients with chronic oro-facial pain. The aim of the present multicentre study was to examine test-retest and interexaminer reliability of intra-oral QST measures in terms of absolute values and z-scores as well as within-session coefficients of variation (CV) values in patients with atypical odontalgia (AO) and healthy pain-free controls. Forty-five patients with AO and 68 healthy controls were subjected to bilateral intra-oral gingival QST and unilateral extratrigeminal QST (thenar) on three occasions (twice on 1 day by two different examiners and once approximately 1 week later by one of the examiners). Intra-class correlation coefficients and kappa values for interexaminer and test-retest reliability were computed. Most of the standardised intra-oral QST measures showed fair to excellent interexaminer (9-12 of 13 measures) and test-retest (7-11 of 13 measures) reliability. Furthermore, no robust differences in reliability measures or within-session variability (CV) were detected between patients with AO and the healthy reference group. These reliability results in chronic orofacial pain patients support earlier suggestions based on data from healthy subjects that intra-oral QST is sufficiently reliable for use as a part of a comprehensive evaluation of patients with somatosensory disturbances or neuropathic pain in the trigeminal region. © 2014 John Wiley & Sons Ltd.
Reliability analysis of a sensitive and independent stabilometry parameter set
Nagymáté, Gergely; Orlovits, Zsanett
2018-01-01
Recent studies have suggested reduced independent and sensitive parameter sets for stabilometry measurements based on correlation and variance analyses. However, the reliability of these recommended parameter sets has not been studied in the literature or not in every stance type used in stabilometry assessments, for example, single leg stances. The goal of this study is to evaluate the test-retest reliability of different time-based and frequency-based parameters that are calculated from the center of pressure (CoP) during bipedal and single leg stance for 30- and 60-second measurement intervals. Thirty healthy subjects performed repeated standing trials in a bipedal stance with eyes open and eyes closed conditions and in a single leg stance with eyes open for 60 seconds. A force distribution measuring plate was used to record the CoP. The reliability of the CoP parameters was characterized by using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimal detectable change (MDC), coefficient of variation (CV) and CV compliance rate (CVCR). Based on the ICC, SEM and MDC results, many parameters yielded fair to good reliability values, while the CoP path length yielded the highest reliability (smallest ICC > 0.67 (0.54–0.79), largest SEM% = 19.2%). Usually, frequency type parameters and extreme value parameters yielded poor reliability values. There were differences in the reliability of the maximum CoP velocity (better with 30 seconds) and mean power frequency (better with 60 seconds) parameters between the different sampling intervals. PMID:29664938
Reliability analysis of a sensitive and independent stabilometry parameter set.
Nagymáté, Gergely; Orlovits, Zsanett; Kiss, Rita M
2018-01-01
Recent studies have suggested reduced independent and sensitive parameter sets for stabilometry measurements based on correlation and variance analyses. However, the reliability of these recommended parameter sets has not been studied in the literature or not in every stance type used in stabilometry assessments, for example, single leg stances. The goal of this study is to evaluate the test-retest reliability of different time-based and frequency-based parameters that are calculated from the center of pressure (CoP) during bipedal and single leg stance for 30- and 60-second measurement intervals. Thirty healthy subjects performed repeated standing trials in a bipedal stance with eyes open and eyes closed conditions and in a single leg stance with eyes open for 60 seconds. A force distribution measuring plate was used to record the CoP. The reliability of the CoP parameters was characterized by using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimal detectable change (MDC), coefficient of variation (CV) and CV compliance rate (CVCR). Based on the ICC, SEM and MDC results, many parameters yielded fair to good reliability values, while the CoP path length yielded the highest reliability (smallest ICC > 0.67 (0.54-0.79), largest SEM% = 19.2%). Usually, frequency type parameters and extreme value parameters yielded poor reliability values. There were differences in the reliability of the maximum CoP velocity (better with 30 seconds) and mean power frequency (better with 60 seconds) parameters between the different sampling intervals.
Özgen, Mustafa; Scheerens, Joseph C.; Reese, R. Neil; Miller, Raymond A.
2010-01-01
Fourteen purple-black American elderberry accessions (Sambucus canadensis L.) obtained from various sites in midwestern USA and then grown at a single Ohio production site in USA were analyzed for their total phenolic (TP) and total monomeric anthocyanin (TMA) contents and for their antioxidant capacity by the ferric reducing antioxidant power (FRAP) and DPPH radical scavenging assays. Total phenolic and anthocyanin contents were measured using the Folin-Ciocalteu reagent and the pH differential methods, respectively. Overall, the phytonutrient contents and antioxidant capacity of our elderberry accessions were similar to those typically reported for black raspberries, blackberries and other dark-fleshed small fruits. Variability among accessions was greatest for TMA content (CV 37.5%); individuals ranged nearly threefold from 1308 to 4004 μg cy3-GE/g on a fresh weight basis. Variation among accessions was also evident for TP, FRAP and DPPH values (CV 14.4, 21.7 and 26.8%, respectively). TP and TMA values were very highly correlated (r = 0.93), although individuals differed in the estimated proportion of total phenolics attributable to anthocyanins. Both TP and TMA also highly correlated to antioxidant capacity values (r = 0.70–0.85). Within this limited study of 14 accessions, variability for phytonutrient content and antioxidant capacity suggested the employment of wild germplasm within an elderberry improvement program to incorporate an array of superior horticultural, post-harvest or processing traits into new or existing cultivars with superior phytonutrient profiles. PMID:20931079
Cortes-Bergoderi, Mery; Goel, Kashish; Murad, Mohammad Hassan; Allison, Thomas; Somers, Virend K; Erwin, Patricia J; Sochor, Ondrej; Lopez-Jimenez, Francisco
2013-12-01
Hispanics, the largest minority in the U.S., have a higher prevalence of several cardiovascular (CV) risk factors than non-Hispanic whites (NHW). However, some studies have shown a paradoxical lower rate of CV events among Hispanics than NHW. To perform a systematic review and a meta-analysis of cohort studies comparing CV mortality and all-cause mortality between Hispanic and NHW populations in the U.S. We searched EMBASE, MEDLINE, Web of Science, and Scopus databases from 1950 through May 2013, using terms related to Hispanic ethnicity, CV diseases and cohort studies. We pooled risk estimates using the least and most adjusted models of each publication. We found 341 publications of which 17 fulfilled the inclusion criteria; data represent 22,340,554 Hispanics and 88,824,618 NHW, collected from 1950 to 2009. Twelve of the studies stratified the analysis by gender, and one study stratified people by place of birth (e.g. U.S.-born, Mexican-born, and Central/South American-born). There was a statistically significant association between Hispanic ethnicity and lower CV mortality (OR 0.67; 95% CI, 0.57-0.78; p<0.001), and lower all-cause mortality (0.72; 95% CI, 0.63-0.82; p<0.001). A subanalysis including only studies that reported prevalence of CV risk factors found similar results. OR for CV mortality among Hispanics was 0.49; 95% CI 0.30-0.80; p-value <0.01; and OR for all-cause mortality was 0.66; 95% CI 0.43-1.02; p-value 0.06. These results confirm the existence of a Hispanic paradox regarding CV mortality. Further studies are needed to identify the mechanisms mediating this protective CV effect in Hispanics. © 2013.
Low, Serena; Lim, Su C; Yeoh, Lee Y; Liu, Yan L; Liu, Jian J; Fun, Sharon; Su, Chang; Zhang, Xiao; Subramaniam, Tavintharan; Sum, Chee F
2017-10-01
In the present study, we examined the association between HbA1c variability and renal disease progression based on estimated glomerular filtration rate (eGFR) decline in patients with type 2 diabetes mellitus (T2DM) in Singapore. Glycemic burden and renal function were retrospectively assessed in 1628 patients in 2002-2014. Multivariable logistic regression was used to assess the relationships between HbA1c variability (expressed as HbA1c coefficient of variation [HbA1c-CV] in quartiles), HbA1c intrapersonal mean (HbA1c-IM), and eGFR decline, adjusted for baseline covariates. Among patients with relatively good glycemic control (i.e. HbA1c-IM below the median cohort value [8.0%]), HbA1c-CV Quartile 4 was associated with eGFR decline (odds ratio [OR] 1.88; 95% confidence interval [CI] 1.10-3.25). The OR for HbA1c-CV Quartile 4 was 2.20 (95% CI 1.24-3.89) after additional adjustment for HbA1c-IM. Where HbA1c-IM was above the median cohort value, HbA1c-CV Quartiles 3 and 4 were associated with eGFR decline, with ORs of 2.60 (95% CI 1.48-4.55) and 3.29 (95% CI 1.89-5.76) respectively. After further adjusting for HbA1c-IM, the ORs for Quartiles 3 and 4 were 2.69 (95% CI 1.53-4.74) and 3.51 (95% CI 1.98-6.21), respectively. Variability in HbA1c is strongly and independently associated with eGFR decline in patients with T2DM independent of mean HbA1c. The findings may highlight the importance of sustained stable glycemic control in management of diabetes mellitus. © 2016 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.
Nolan, Bernard T.; Fienen, Michael N.; Lorenz, David L.
2015-01-01
We used a statistical learning framework to evaluate the ability of three machine-learning methods to predict nitrate concentration in shallow groundwater of the Central Valley, California: boosted regression trees (BRT), artificial neural networks (ANN), and Bayesian networks (BN). Machine learning methods can learn complex patterns in the data but because of overfitting may not generalize well to new data. The statistical learning framework involves cross-validation (CV) training and testing data and a separate hold-out data set for model evaluation, with the goal of optimizing predictive performance by controlling for model overfit. The order of prediction performance according to both CV testing R2 and that for the hold-out data set was BRT > BN > ANN. For each method we identified two models based on CV testing results: that with maximum testing R2 and a version with R2 within one standard error of the maximum (the 1SE model). The former yielded CV training R2 values of 0.94–1.0. Cross-validation testing R2 values indicate predictive performance, and these were 0.22–0.39 for the maximum R2 models and 0.19–0.36 for the 1SE models. Evaluation with hold-out data suggested that the 1SE BRT and ANN models predicted better for an independent data set compared with the maximum R2 versions, which is relevant to extrapolation by mapping. Scatterplots of predicted vs. observed hold-out data obtained for final models helped identify prediction bias, which was fairly pronounced for ANN and BN. Lastly, the models were compared with multiple linear regression (MLR) and a previous random forest regression (RFR) model. Whereas BRT results were comparable to RFR, MLR had low hold-out R2 (0.07) and explained less than half the variation in the training data. Spatial patterns of predictions by the final, 1SE BRT model agreed reasonably well with previously observed patterns of nitrate occurrence in groundwater of the Central Valley.
Juhaimi, Fahad Al; Ghafoor, Kashif; Özcan, Mehmet Musa
2012-02-01
The physical and chemical properties of the date (Phoenix dactylifera L.) fruit seeds from seven date samples (Soukari, Soulag, Barhi, Khulas, Rozaiz, Soughi and Monaif) were evaluated. Energy values of dried and ground seeds were found between 4340 kcal/kg (Barhi cv) and 4795 kcal/kg (Rozaiz cv). Also, while crude oil content of seeds were established between 4.68% (Khulas cv) and 7.96% (Monaif cv), crude protein contents were found at the levels between 3.71% (Soulag cv) and 5.47% (Barhi cv). The antioxidant activity of seeds obtained from different date fruits changed between 78.03 (mg/ml) (Monaif cv) and 79.94 (mg/ml) (Barhi cv). In addition, the total phenol contents of seeds were found between 1.98 mg gallic acid equivalents (GAE)/100 g (Barhi cv) and 4.65 mg GAE/100 g (Soughi cv). The most abundant fatty acids of the date seed oils were oleic, lauric, myristic, palmitic and stearic acids. Ca, Mg, K and P contents of date seeds were found at the high concentrations.
Temperature is the key to altitudinal variation of phenolics in Arnica montana L. cv. ARBO.
Albert, Andreas; Sareedenchai, Vipaporn; Heller, Werner; Seidlitz, Harald K; Zidorn, Christian
2009-05-01
Plants in alpine habitats are exposed to many environmental stresses, in particular temperature and radiation extremes. Recent field experiments on Arnica montana L. cv. ARBO indicated pronounced altitudinal variation in plant phenolics. Ortho-diphenolics increased with altitude compared to other phenolic compounds, resulting in an increase in antioxidative capacity of the tissues involved. Factors causing these variations were investigated by climate chamber (CC) experiments focusing on temperature and ultraviolet (UV)-B radiation. Plants of A. montana L. cv. ARBO were grown in CCs under realistic climatic and radiation regimes. Key factors temperature and UV-B radiation were altered between different groups of plants. Subsequently, flowering heads were analyzed by HPLC for their contents of flavonoids and caffeic acid derivatives. Surprisingly, increased UV-B radiation did not trigger any change in phenolic metabolites in Arnica. In contrast, a pronounced increase in the ratio of B-ring ortho-diphenolic (quercetin) compared to B-ring monophenolic (kaempferol) flavonols resulted from a decrease in temperature by 5 degrees C in the applied climate regime. In conclusion, enhanced UV-B radiation is probably not the key factor triggering shifts in the phenolic composition in Arnica grown at higher altitudes but rather temperature, which decreases with altitude.
Analysis of Darwin Rainfall Data: Implications on Sampling Strategy
NASA Technical Reports Server (NTRS)
Rafael, Qihang Li; Bras, Rafael L.; Veneziano, Daniele
1996-01-01
Rainfall data collected by radar in the vicinity of Darwin, Australia, have been analyzed in terms of their mean, variance, autocorrelation of area-averaged rain rate, and diurnal variation. It is found that, when compared with the well-studied GATE (Global Atmospheric Research Program Atlantic Tropical Experiment) data, Darwin rainfall has larger coefficient of variation (CV), faster reduction of CV with increasing area size, weaker temporal correlation, and a strong diurnal cycle and intermittence. The coefficient of variation for Darwin rainfall has larger magnitude and exhibits larger spatial variability over the sea portion than over the land portion within the area of radar coverage. Stationary, and nonstationary models have been used to study the sampling errors associated with space-based rainfall measurement. The nonstationary model shows that the sampling error is sensitive to the starting sampling time for some sampling frequencies, due to the diurnal cycle of rain, but not for others. Sampling experiments using data also show such sensitivity. When the errors are averaged over starting time, the results of the experiments and the stationary and nonstationary models match each other very closely. In the small areas for which data are available for I>oth Darwin and GATE, the sampling error is expected to be larger for Darwin due to its larger CV.
NASA Astrophysics Data System (ADS)
Zhang, Y.; Guo, S.; Zhao, M.; Du, L.; Li, R.; Jiang, J.; Wang, R.; Li, N.
2015-01-01
Temperature sensitivity of SOC mineralization (Q10) determines how strong the feedback from global warming may be on the atmospheric CO2 concentration, thus understanding the factors influencing the interannual variation in Q10 is important to accurately estimate the local soil carbon cycle. In situ SOC mineralization was measured using an automated CO2 flux system (Li-8100) in long-term bare fallow soil in the Loess Plateau (35° 12' N, 107° 40' E) in Changwu, Shaanxi, China form 2008 to 2013. The results showed that the annual cumulative SOC mineralization ranged from 226 to 298 g C m-2 y-1 (mean =253 g C m-2 y-1; CV =13%), annual Q10 ranged from 1.48 to 1.94 (mean =1.70; CV =10%), and annual soil moisture content ranged from 38.6 to 50.7% WFPS (mean =43.8% WFPS; CV =11%), which were mainly affected by the frequency and distribution of precipitation. Annual Q10 showed a negative quadratic correlation with soil moisture. In conclusion, understanding of the relationships between interannual variation in Q10 of SOC mineralization, soil moisture and precipitation is important to accurately estimate the local carbon cycle, especially under the changing climate.
Fajardo, Alex; Piper, Frida I
2011-01-01
• The focus of the trait-based approach to study community ecology has mostly been on trait comparisons at the interspecific level. Here we quantified intraspecific variation and covariation of leaf mass per area (LMA) and wood density (WD) in monospecific forests of the widespread tree species Nothofagus pumilio to determine its magnitude and whether it is related to environmental conditions and ontogeny. We also discuss probable mechanisms controlling the trait variation found. • We collected leaf and stem woody tissues from 30-50 trees of different ages (ontogeny) from each of four populations at differing elevations (i.e. temperatures) and placed at each of three locations differing in soil moisture. • The total variation in LMA (coefficient of variation (CV) = 21.14%) was twice that of WD (CV = 10.52%). The total variation in traits was never less than 23% when compared with interspecific studies. Differences in elevation (temperature) for the most part explained variation in LMA, while differences in soil moisture and ontogeny explained the variation in WD. Traits covaried similarly in the altitudinal gradient only. • Functional traits of N. pumilio exhibited nonnegligible variation; LMA varied for the most part with temperature, while WD mostly varied with moisture and ontogeny. We demonstrate that environmental variation can cause important trait variation without species turnover. © The Authors (2010). Journal compilation © New Phytologist Trust (2010).
Anonymous voting for multi-dimensional CV quantum system
NASA Astrophysics Data System (ADS)
Rong-Hua, Shi; Yi, Xiao; Jin-Jing, Shi; Ying, Guo; Moon-Ho, Lee
2016-06-01
We investigate the design of anonymous voting protocols, CV-based binary-valued ballot and CV-based multi-valued ballot with continuous variables (CV) in a multi-dimensional quantum cryptosystem to ensure the security of voting procedure and data privacy. The quantum entangled states are employed in the continuous variable quantum system to carry the voting information and assist information transmission, which takes the advantage of the GHZ-like states in terms of improving the utilization of quantum states by decreasing the number of required quantum states. It provides a potential approach to achieve the efficient quantum anonymous voting with high transmission security, especially in large-scale votes. Project supported by the National Natural Science Foundation of China (Grant Nos. 61272495, 61379153, and 61401519), the Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20130162110012), and the MEST-NRF of Korea (Grant No. 2012-002521).
Neuropeptide Y - an early biomarker for cerebral vasospasm after aneurysmal subarachnoid hemorrhage.
Schebesch, Karl-Michael; Brawanski, Alexander; Bele, Sylvia; Schödel, Petra; Herbst, Andreas; Bründl, Elisabeth; Kagerbauer, Simone Maria; Martin, Jan; Lohmeier, Anette; Stoerr, Eva-Maria; Proescholdt, Martin
2013-12-01
In the human brain, the potent vasoconstrictive neuropeptide Y (NPY) is abundantly expressed. Neuropeptide Y, which is stored in perivascular nerve fibers of the cerebral arteries, regulates the cerebral vascular diameter as well as cerebral blood flow. However, the role of NPY in the pathogenesis of cerebral vasospasm (CV) related to subarachnoid hemorrhage (SAH) is unclear. We prospectively analyzed and compared the release of endogenous NPY in the cerebrospinal fluid (CSF) of 66 patients with SAH to NPY release in a control group. Additionally, we correlated the levels of NPY with CV and consecutive ischemic stroke. Sixty-six consecutive patients (40 women, 26 men; mean age 53·1 years) with aneurysmal SAH were included. In the SAH group, CSF was drawn daily from day 1 to day 10 after the onset of SAH. The CSF of 29 patients undergoing spinal anesthesia for orthopedic surgery served as control samples. The NPY levels were determined in duplicate CSF samples by means of a competitive enzyme immunoassay (EIA). The levels of NPY in CSF were correlated with the development of CV over the 10-day period after the onset of SAH and to the occurrence of consecutive ischemic stroke. To evaluate CSF NPY levels as a predictive biomarker for vasospasm, we calculated the sensitivity and specificity as well as the positive and negative predictive values. The NPY levels were significantly higher in the SAH group than in the control group (p < 0·001). The treatment modality (clip versus coil) did not influence the level of NPY in CSF (p > 0·05). Patients with CV showed significantly higher NPY levels than patients without CV during the entire observation period. The NPY levels of the non-CV group dissipated over time, whereas the CV group showed continuously increasing values. The NPY levels from day 4 to 10 were significantly higher in patients with CV-related stroke than in non-stroke patients. Using 0·3 ng/ml as a cut-off value, NPY levels on day 3 predicted the occurrence of CV with a sensitivity and specificity of 82% and 72%, respectively. High NPY levels, starting on day 4, significantly correlated with poor Glasgow Outcome Score grading at the follow-up (p < 0·05). Our data indicate that NPY is involved in the pathogenesis of SAH-related CV and ischemia. Neuropeptide Y represents an early and reliable biomarker for the prediction of CV and consecutive stroke due to aneurysmal SAH.
NASA Astrophysics Data System (ADS)
Zhang, Y. J.; Guo, S. L.; Zhao, M.; Du, L. L.; Li, R. J.; Jiang, J. S.; Wang, R.; Li, N. N.
2015-06-01
Temperature sensitivity of soil organic carbon (SOC) mineralization (i.e., Q10) determines how strong the feedback from global warming may be on the atmospheric CO2 concentration; thus, understanding the factors influencing the interannual variation in Q10 is important for accurately estimating local soil carbon cycle. In situ SOC mineralization rate was measured using an automated CO2 flux system (Li-8100) in long-term bare fallow soil in the Loess Plateau (35°12' N, 107°40' E) in Changwu, Shaanxi, China from 2008 to 2013. The results showed that the annual cumulative SOC mineralization ranged from 226 to 298 g C m-2 yr-1, with a mean of 253 g C m-2 yr-1 and a coefficient of variation (CV) of 13%, annual Q10 ranged from 1.48 to 1.94, with a mean of 1.70 and a CV of 10%, and annual soil moisture content ranged from 38.6 to 50.7% soil water-filled pore space (WFPS), with a mean of 43.8% WFPS and a CV of 11%, which were mainly affected by the frequency and distribution of precipitation. Annual Q10 showed a quadratic correlation with annual mean soil moisture content. In conclusion, understanding of the relationships between interannual variation in Q10, soil moisture, and precipitation are important to accurately estimate the local carbon cycle, especially under the changing climate.
NASA Astrophysics Data System (ADS)
Woźniak, Sławomir B.; Sagan, Sławomir; Zabłocka, Monika; Stoń-Egiert, Joanna; Borzycka, Karolina
2018-06-01
The empirical relationships were examined of spectral characteristics of light scattering and backscattering by particles suspended in seawater in relation to the dry mass concentration of particles and the bulk proportions of their organic and inorganic fractions. The analyses were based on empirical data collected in the surface waters of the southern and central Baltic Sea at different times of the year. It was found that the average scattering and backscattering coefficients, normalized to the dry mass concentration of particles for all our Baltic Sea data (i.e. mass-specific optical coefficients), were characterized by large coefficients of variation (CV) of the order of 30% at all the visible light wavelengths analysed. At wavelength 555 nm the average mass-specific scattering coefficient was ca 0.75 m2 g- 1 (CV = 31%); the corresponding value for backscattering was 0.0072 m2 g- 1 (CV = 29%). The analyses confirmed that some of the observed variations could be explained by changes in the proportions of organic and inorganic fractions of suspended matter. The average organic fraction in all the samples was as high as 83% of the total dry mass concentration but in individual cases it varied between < 50% and up to 100%. Simple, two-variable parameterizations of scattering and backscattering coefficients were derived as functions of the organic and inorganic fraction concentrations. The statistical relationship between the backscattering ratio and the ratio of the organic fraction to the total dry mass of suspended matter was also found: this can be used in practical interpretations of in situ optical measurements. In addition, the variability in particle size distributions recorded with a Coulter counter indicated its potentially highly significant influence on the light scattering properties of particles suspended in Baltic Sea waters.
Ivaničová, Zuzana; Jakobson, Irena; Reis, Diana; Šafář, Jan; Milec, Zbyněk; Abrouk, Michael; Doležel, Jaroslav; Järve, Kadri; Valárik, Miroslav
2016-09-25
Flowering time variation was identified within a mapping population of doubled haploid lines developed from a cross between the introgressive line 8.1 and spring bread wheat cv. Tähti. The line 8.1 carried introgressions from tetraploid Triticum militinae in the cv. Tähti genetic background on chromosomes 1A, 2A, 4A, 5A, 7A, 1B and 5B. The most significant QTL for the flowering time variation was identified within the introgressed region on chromosome 5A and its largest effect was associated with the VRN-A1 locus, accounting for up to 70% of phenotypic variance. The allele of T. militinae origin was designated as VRN-A1f-like. The effect of the VRN-A1f-like allele was verified in two other mapping populations. QTL analysis identified that in cv. Tähti and cv. Mooni genetic background, VRN-A1f-like allele incurred a delay of 1.9-18.6 days in flowering time, depending on growing conditions. Sequence comparison of the VRN-A1f-like and VRN-A1a alleles from the parental lines of the mapping populations revealed major mutations in the promoter region as well as in the first intron, including insertion of a MITE element and a large deletion. The sequence variation allowed construction of specific diagnostic PCR markers for VRN-A1f-like allele determination. Identification and quantification of the effect of the VRN-A1f-like allele offers a useful tool for wheat breeding and for studying fine-scale regulation of flowering pathways in wheat. Copyright © 2016 Elsevier B.V. All rights reserved.
Jiang, Zhenzuo; Yang, Jing; Wang, Yuefei
2017-12-28
The safety and effectiveness of traditional Chinese medicine (TCM) in clinical practice is directly related to the quality of TCM. And, the quality control of TCM is a pivotal issue to the quality of TCM, but also an obstacle impeding the modernization of TCM. The purpose of this work is to compile and develop a strategy based on discrimination and identification of quality markers (Q-markers) for quality control of TCM. Mainly established by seven variables derived from four dimensions including content, stability, pharmacokinetics and pharmacology, the 'Spider-web' mode was undertaken to assess the Q-marker property of candidate compounds originated from TCM by taking regression area (A) and coefficient variation (CV) of the tested compounds into account. The importance index (ImI), ImI = A × 1/CV, was suggested to focus Q-markers. The compounds with larger regression area (A) and less coefficient variation (CV) are preferentially adopted as Q-markers, which should possess the satisfactory properties of content, stability, pharmacokinetics and pharmacological activity. To the contrary, the compounds are excluded on the grounds of the unsatisfactory Q-markers' property, less regression area (A) and larger coefficient variation (CV), which cannot represent the quality of TCM. The 'Spider-web' mode can filter out the redundant constituents and focus on the key indexes of quality control - Q-markers. The screened Q-markers possess the optimal integrated properties of content, stability, pharmacokinetics and pharmacology among the numerous and complicated ingredients of TCM, which can comprehensively characterize inherent quality of TCM. In summary, the novel strategy established in this work provides a valuable perspective for the quality control of TCM. Copyright © 2017 Elsevier GmbH. All rights reserved.
Shields, E; Seiden-Long, I; Massie, S; Passante, S; Leguillette, R
2016-06-13
Cardiac troponin-I assays have been validated in horses.'High-sensitivity' cardiac troponin assays are now the standard in human cardiology. Appropriately validate the'high-sensitivity' cardiac Troponin-T (hscTnT) assay for clinical use in horses, establish reference intervals, determine the biological variation, and demonstrate assay utility in selected clinical cases. Analytical validation of the Roche hscTnT assay included within- and between-run precision, linear dose response, limit of quantitation (LoQ), stability, and comparison with cTn-I (iSTAT). Reference intervals and biological variation were determined using adult, healthy, Non-Competition Horses (N = 125) and Racing-Thoroughbreds (N = 178). HscTnT levels were measured in two horses with cardiac pathology. The hscTnT demonstrates acceptable within-run (L1 = 6.5 ng/L, CV 14.9 %, L2 = 10.1 ng/L, CV 8.7 %, L3 = 15.3 ng/L, CV 5.4 %) and between-run precision (L1 = 12.2 ng/L, CV 8.4 %, L2 = 57.0 ng/L, CV 8.4 %, L3 = 256.0 ng/L, CV 9.0 %). The assay was linear from 3 to 391 ng/L. The LoQ was validated at 3 ng/L. Samples demonstrated insignificant decay over freeze-thaw cycle. Comparison with cTnI assay showed excellent correlation (range: 8.0-3535.0 ng/L, R(2) = 0.9996). Reference intervals: The upper 95(th) and 99(th) percentile of the hscTnT population distribution were 6.8 and 16.2 ng/L in Non-Competition Horses, and 14.0 and 23.2 ng/L in Racing-Thoroughbreds. Between-breed, diurnal effect, and between-day variation was below LoQ. Two clinical cases with presumed cardiac pathology had hscTnT levels of 220.9 ng/L and 5723.0 ng/L. This benchmark study is the first to comply with CLSI guidelines, thus further establishing the performance characteristics of the hscTnT assay, and reference intervals in healthy horses. Two clinical cases demonstrated further the clinical utility of the assay.
Sobol, Eyal; Bialer, Meir
2004-05-01
In the one-compartment model following i.v. administration the mean residence time (MRT) of a drug is always greater than its half-life (t(1/2)). However, following i.v. administration, drug plasma concentration (C) versus time (t) is best described by a two-compartment model or a two exponential equation:C=Ae(-alpha t)+Be(-beta t), where A and B are concentration unit-coefficients and alpha and beta are exponential coefficients. The relationships between t(1/2) and MRT in the two-compartment model have not been explored and it is not clear whether in this model too MRT is always greater than t(1/2). In the current paper new equations have been developed that describe the relationships between the terminal t(1/2) (or t(1/2 beta)) and MRT in the two-compartment model following administration of i.v. bolus, i.v. infusion (zero order input) and oral administration (first order input). A critical value (CV) equals to the quotient of (1-ln2) and (1-beta/alpha) (CV=(1-ln2)/(1-beta/alpha)=0.307/(1-beta/alpha)) has been derived and was compared with the fraction (f(1)) of drug elimination or AUC (AUC-area under C vs t curve) associated with the first exponential term of the two-compartment equation (f(1)=A/alpha/AUC). Following i.v. bolus, CV ranges between a minimal value of 0.307 (1-ln2) and infinity. As long as f(1)
Note on the coefficient of variations of neuronal spike trains.
Lengler, Johannes; Steger, Angelika
2017-08-01
It is known that many neurons in the brain show spike trains with a coefficient of variation (CV) of the interspike times of approximately 1, thus resembling the properties of Poisson spike trains. Computational studies have been able to reproduce this phenomenon. However, the underlying models were too complex to be examined analytically. In this paper, we offer a simple model that shows the same effect but is accessible to an analytic treatment. The model is a random walk model with a reflecting barrier; we give explicit formulas for the CV in the regime of excess inhibition. We also analyze the effect of probabilistic synapses in our model and show that it resembles previous findings that were obtained by simulation.
Müller, Hans-Peter; Grön, Georg; Sprengelmeyer, Reiner; Kassubek, Jan; Ludolph, Albert C.; Hobbs, Nicola; Cole, James; Roos, Raymund A.C.; Duerr, Alexandra; Tabrizi, Sarah J.; Landwehrmeyer, G. Bernhard; Süssmuth, Sigurd D.
2013-01-01
Purpose Assessment of the feasibility to average diffusion tensor imaging (DTI) metrics of MRI data acquired in the course of a multicenter study. Materials and methods Sixty-one early stage Huntington's disease patients and forty healthy controls were studied using four different MR scanners at four European sites with acquisition protocols as close as possible to a given standard protocol. The potential and feasibility of averaging data acquired at different sites was evaluated quantitatively by region-of-interest (ROI) based statistical comparisons of coefficients of variation (CV) across centers, as well as by testing for significant group-by-center differences on averaged fractional anisotropy (FA) values between patients and controls. In addition, a whole-brain based statistical between-group comparison was performed using FA maps. Results The ex post facto statistical evaluation of CV and FA-values in a priori defined ROIs showed no differences between sites above chance indicating that data were not systematically biased by center specific factors. Conclusion Averaging FA-maps from DTI data acquired at different study sites and different MR scanner types does not appear to be systematically biased. A suitable recipe for testing on the possibility to pool multicenter DTI data is provided to permit averaging of DTI-derived metrics to differentiate patients from healthy controls at a larger scale. PMID:24179771
Performance evaluation of the microINR® point-of-care INR-testing system.
Joubert, J; van Zyl, M C; Raubenheimer, J
2018-04-01
Point-of-care International Normalised Ratio (INR) testing is used frequently. We evaluated the microINR ® POC system for accuracy, precision and measurement repeatability, and investigated instrument and test chip variability and error rates. Venous blood INRs of 210 patients on warfarin were obtained with Thromborel ® S on the Sysmex CS-2100i ® analyser and compared with capillary blood microINR ® values. Precision was assessed using control materials. Measurement repeatability was calculated on 51 duplicate finger-prick INRs. Triplicate finger-prick INRs using three different instruments (30 patients) and three different test chip lots (29 patients) were used to evaluate instrument and test chip variability. Linear regression analysis of microINR ® and Sysmex CS2100i ® values showed a correlation coefficient of 0.96 (P < .0001) and a positive proportional bias of 4.4%. Dosage concordance was 93.8% and clinical agreement 95.7%. All acceptance criteria based on ISO standard 17593:2007 system accuracy requirements were met. Control material coefficients of variation (CV) varied from 6.2% to 16.7%. The capillary blood measurement repeatability CV was 7.5%. No significant instrument (P = .93) or test chip (P = .81) variability was found, and the error rate was low (2.8%). The microINR ® instrument is accurate and precise for monitoring warfarin therapy. © 2017 John Wiley & Sons Ltd.
Jensen, Victoria S; Porsgaard, Trine; Lykkesfeldt, Jens; Hvid, Henning
2016-01-01
Laboratory rodents are available as either genetically defined inbred strains or genetically undefined outbred stocks. As outbred rodents are generally thought to display a higher level of phenotypic variation compared to inbred strains, it has been argued that experimental studies should preferentially be performed by using inbred rodents. However, very few studies with adequate sample sizes have in fact compared phenotypic variation between inbred strains and outbred stocks of rodents and moreover, these studies have not reached consistent conclusions. The aim of the present study was to compare the phenotypic variation in commonly used experimental readouts within obesity and diabetes research, for four of the most frequently used mouse strains: inbred C57BL/6 and BALB/c and outbred NMRI and CD-1 mice. The variation for all readouts was examined by calculating the coefficient of variation (CV), i.e., the relative variation, including a 95% confidence interval for the CV. We observed that for the majority of the selected readouts, inbred and outbred mice showed comparable phenotypic variation. The observed variation appeared highly influenced by strain choice and type of readout, which suggests that these collectively would serve as more predictive of the phenotypic variation than the more general classification of mice as inbred or outbred based on genetic heterogeneity. PMID:27648148
Bittencourt, Marcio S; Hulten, Edward A; Ghoshhajra, Brian; Abbara, Suhny; Murthy, Venkatesh L; Divakaran, Sanjay; Nasir, Khurram; Gowdak, Luis Henrique W; Riella, Leonardo V; Chiumiento, Marco; Hoffmann, Udo; Di Carli, Marcelo F; Blankstein, Ron
2015-07-01
It is unknown whether mild chronic kidney disease (CKD) is associated with adverse cardiovascular (CV) prognosis after accounting for coronary artery disease (CAD). Here we evaluated the interplay between CKD and CAD in predicting CV death or myocardial infarction (MI) and all-cause death. We included 1541 consecutive patients in the Partners registry (mean age 55 years, 43% female) over 18 years old with no known prior CAD who underwent coronary computed tomography angiography (CCTA). The results of CCTA were categorized as normal, nonobstructive (under half), or obstructive (half and over). Overall, 653 of the patients had no CAD, 583 had nonobstructive CAD, and 305 had obstructive CAD, while 1299 had eGFR over 60 ml/min per 1.73 m(2) and 242 had an eGFR under this value. The presence and severity of CAD was significantly associated with an increased rate of CV death or MI and all-cause death, even after adjustment for age, gender, symptoms, and risk factors. Similarly, reduced eGFR was significantly associated with CV death or MI and all-cause death after similar adjustment. The addition of reduced GFR to a model which included both clinical variables and CCTA findings resulted in significant improvement in the prediction of CV death or MI and all-cause death. Thus, among individuals referred for CCTA to evaluate CAD, renal dysfunction is associated with an increased rate of CV events, mainly driven by an increase in the rate of noncoronary CV events. In this group of patients, both eGFR and the presence and severity of CAD together improve the prediction of future CV events and death.
Enterovirus Migration Patterns between France and Tunisia.
Othman, Ines; Mirand, Audrey; Slama, Ichrak; Mastouri, Maha; Peigue-Lafeuille, Hélène; Aouni, Mahjoub; Bailly, Jean-Luc
2015-01-01
The enterovirus (EV) types echovirus (E-) 5, E-9, and E-18, and coxsackievirus (CV-) A9 are infrequently reported in human diseases and their epidemiologic features are poorly defined. Virus transmission patterns between countries have been estimated with phylogenetic data derived from the 1D/VP1 and 3CD gene sequences of a sample of 74 strains obtained in France (2000-2012) and Tunisia (2011-2013) and from the publicly available sequences. The EV types (E-5, E-9, and E-18) exhibited a lower worldwide genetic diversity (respective number of genogroups: 4, 5, and 3) in comparison to CV-A9 (n = 10). The phylogenetic trees estimated with both 1D/VP1 and 3CD sequence data showed variations in the number of co-circulating lineages over the last 20 years among the four EV types. Despite the low number of genogroups in E-18, the virus exhibited the highest number of recombinant 3CD lineages (n = 10) versus 4 (E-5) to 8 (E-9). The phylogenies provided evidence of multiple transportation events between France and Tunisia involving E-5, E-9, E-18, and CV-A9 strains. Virus spread events between France and 17 other countries in five continents had high probabilities of occurrence as those between Tunisia and two European countries other than France. All transportation events were supported by BF values > 10. Inferring the source of virus transmission from phylogenetic data may provide insights into the patterns of sporadic and epidemic diseases caused by EVs.
Zhang, Yong; Sun, Qiang; Cui, Hui; Yan, Dongmei; Fan, Qin; Song, Yang; Zhu, Shuangli; Li, Xiaolei; Huang, Guohong; Ji, Tianjiao; Hu, Lan; Wang, Dongyan; Yang, Qian; Xu, Wenbo
2016-01-01
Poliomyelitis associated with circulating vaccine-derived polioviruses (cVDPVs) is a serious public health issue in the post-eradication era, and the occurrence of recombinant cVDPVs emphasizes the need to elucidate enterovirus C (EV-C) epidemiology. Stool samples were collected from 826 healthy children in Southern Xinjiang in 2011 to investigate EV-C circulation and epidemiology. Thirty-six EV-Cs were isolated and assigned to eight EV-C serotypes by molecular serotyping, suggesting the circulation of diverse EV-Cs in Xinjiang. Phylogenetic analysis showed that the Xinjiang EV-C strains had larger variation compared to the prototype and other modern strains. Additionally, the results showed unique characteristics of Xinjiang EV-Cs, such as the cytopathicity of CV-A1 strains to RD cells; the high divergence in CV-A11, CV-A13, CV-A17, and CV-A20 strains; the divergence of Xinjiang CV-A24 from AHC-related CV-A24 variant stains distributed worldwide; and the circulation of two novel EV-C serotypes (EV-C96 and EV-C99). Evaluations of this dense and diverse EV-C ecosystem will help elucidate the processes shaping enteroviral biodiversity. This study will improve our understanding of the evolution of enteroviruses and the recombination potential between polioviruses and other EV-Cs. PMID:27642136
Terada, Tasuku; Loehr, Sarah; Guigard, Emmanuel; McCargar, Linda J; Bell, Gordon J; Senior, Peter; Boulé, Normand G
2014-08-01
This study determined the test-retest reliability of a continuous glucose monitoring system (CGMS) (iPro™2; Medtronic, Northridge, CA) under standardized conditions in individuals with type 2 diabetes (T2D). Fourteen individuals with T2D spent two nonconsecutive days in a calorimetry unit. On both days, meals, medication, and exercise were standardized. Glucose concentrations were measured continuously by CGMS, from which daily mean glucose concentration (GLU(mean)), time spent in hyperglycemia (t(>10.0 mmol/L)), and meal, exercise, and nocturnal mean glucose concentrations, as well as glycemic variability (SD(w), percentage coefficient of variation [%cv(w)], mean amplitude of glycemic excursions [MAGEc, MAGE(ave), and MAGE(abs.gos)], and continuous overlapping net glycemic action [CONGA(n)]) were estimated. Absolute and relative reliabilities were investigated using coefficient of variation (CV) and intraclass correlation, respectively. Relative reliability ranged from 0.77 to 0.95 (P<0.05) for GLU(mean) and meal, exercise, and nocturnal glycemia with CV ranging from 3.9% to 11.7%. Despite significant relative reliability (R=0.93; P<0.01), t(>10.0 mmol/L) showed larger CV (54.7%). Among the different glycemic variability measures, a significant between-day difference was observed in MAGEc, MAGE(ave), CONGA6, and CONGA12. The remaining measures (i.e., SD(w), %cv(w), MAGE(abs.gos), and CONGA1-4) indicated no between-day differences and significant relative reliability. In individuals with T2D, CGMS-estimated glycemic profiles were characterized by high relative and absolute reliability for both daily and shorter-term measurements as represented by GLUmean and meal, exercise, and nocturnal glycemia. Among the different methods to calculate glycemic variability, our results showed SD(w), %cv(w), MAGE(abs.gos), and CONGAn with n ≤ 4 were reliable measures. These results suggest the usefulness of CGMS in clinical trials utilizing repeated measured.
Complex-valued time-series correlation increases sensitivity in FMRI analysis.
Kociuba, Mary C; Rowe, Daniel B
2016-07-01
To develop a linear matrix representation of correlation between complex-valued (CV) time-series in the temporal Fourier frequency domain, and demonstrate its increased sensitivity over correlation between magnitude-only (MO) time-series in functional MRI (fMRI) analysis. The standard in fMRI is to discard the phase before the statistical analysis of the data, despite evidence of task related change in the phase time-series. With a real-valued isomorphism representation of Fourier reconstruction, correlation is computed in the temporal frequency domain with CV time-series data, rather than with the standard of MO data. A MATLAB simulation compares the Fisher-z transform of MO and CV correlations for varying degrees of task related magnitude and phase amplitude change in the time-series. The increased sensitivity of the complex-valued Fourier representation of correlation is also demonstrated with experimental human data. Since the correlation description in the temporal frequency domain is represented as a summation of second order temporal frequencies, the correlation is easily divided into experimentally relevant frequency bands for each voxel's temporal frequency spectrum. The MO and CV correlations for the experimental human data are analyzed for four voxels of interest (VOIs) to show the framework with high and low contrast-to-noise ratios in the motor cortex and the supplementary motor cortex. The simulation demonstrates the increased strength of CV correlations over MO correlations for low magnitude contrast-to-noise time-series. In the experimental human data, the MO correlation maps are noisier than the CV maps, and it is more difficult to distinguish the motor cortex in the MO correlation maps after spatial processing. Including both magnitude and phase in the spatial correlation computations more accurately defines the correlated left and right motor cortices. Sensitivity in correlation analysis is important to preserve the signal of interest in fMRI data sets with high noise variance, and avoid excessive processing induced correlation. Copyright © 2016 Elsevier Inc. All rights reserved.
Liquid Jet Cavitation via Molecular Dynamics
NASA Astrophysics Data System (ADS)
Ashurst, W. T.
1997-11-01
A two-dimensional molecular dynamics simulation of a liquid jet is used to investigate cavitation in a diesel-like fuel injector. A channel with a length four times its width has been examined at various system sizes (widths of 20 to 160 σ, where σ is the zero energy location in the Lennard-Jones potential). The wall boundary condition is Maxwell's diffuse reflection, similar to the work by Sun & Ebner (Phys. Rev A 46, 4813, 1992). Currently, the jet exhausts into a vacuum, but a second, low density gas will be incorporated to represent the compressed air in a diesel chamber. Four different flow rates are examined. With ρ U equal to √mɛ/σ^2 (the largest flow rate) the static pressure decreases by a factor of twenty between the channel entrance and exit. The largest flow rate has a parabolic velocity profile with almost constant density across the channel. The smallest flow rate has the same velocity profile but the density exhibits a large variation, with the minimum value in the channel center. Thus, the product ρ U is nearly constant across the channel at this flow rate. The discharge coefficient CD has a small variation with flow rate, but the velocity coefficient CV varies with the amount of two-phase fluid within the channel. The ratio of CV to CD varies from 1.3 (largest flow rate) to 2.0 (the smallest flow rate, which is one-eighth of the largest).
Precision of Four Acoustic Bone Measurement Devices
NASA Technical Reports Server (NTRS)
Miller, Christopher; Feiveson, Alan H.; Shackelford, Linda; Rianon, Nahida; LeBlanc, Adrian
2000-01-01
Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Done Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift, The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values ( < 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.
Precision of Four Acoustic Bone Measurement Devices
NASA Technical Reports Server (NTRS)
Miller, Christopher; Rianon, Nahid; Feiveson, Alan; Shackelford, Linda; LeBlanc, Adrian
2000-01-01
Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Bone Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift. The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values (less than 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.
Benetos, Athanase; Gautier, Sylvie; Labat, Carlos; Salvi, Paolo; Valbusa, Filippo; Marino, Francesca; Toulza, Olivier; Agnoletti, Davide; Zamboni, Mauro; Dubail, Delphine; Manckoundia, Patrick; Rolland, Yves; Hanon, Olivier; Perret-Guillaume, Christine; Lacolley, Patrick; Safar, Michel E; Guillemin, Francis
2012-10-16
The aim of the longitudinal PARTAGE study was to determine the predictive value of blood pressure (BP) and pulse pressure amplification, a marker of arterial function, for overall mortality (primary endpoint) and major cardiovascular (CV) events, in subjects older than 80 years of age living in a nursing home. Assessment of pulse indexes may be important in the evaluation of the CV risk in very elderly frail subjects. A total of 1,126 subjects (874 women) who were living in French and Italian nursing homes were enrolled (mean age, 88 ± 5 years). Central (carotid) to peripheral (brachial) pulse pressure amplification (PPA) was calculated with the help of an arterial tonometer. Clinical and 3-day self-measurements of BP were conducted. During the 2-year follow-up, 247 subjects died, and 228 experienced major CV events. The PPA was a predictor of total mortality and major CV events in this population. A 10% increase in PPA was associated with a 24% (p < 0.0003) decrease in total mortality and a 17% (p < 0.01) decrease in major CV events. Systolic BP, diastolic BP, or pulse pressure were either not associated or inversely correlated with total mortality and major CV events. In very elderly individuals living in nursing homes, low PPA from central to peripheral arteries strongly predicts mortality and adverse effects. Assessment of this parameter could help in risk estimation and improve diagnostic and therapeutic strategies in very old, polymedicated persons. In contrast, high BP is not associated with higher risk of mortality or major CV events in this population. (Predictive Values of Blood Pressure and Arterial Stiffness in Institutionalized Very Aged Population [PARTAGE]; NCT00901355). Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Fang; Dang, Cong; Chang, Xuefei; Tian, Junce; Lu, Zengbin; Chen, Yang; Ye, Gongyin
2017-02-01
The current difficulty facing risk evaluations of Bacillus thuringiensis (Bt) crops on nontarget arthropods (NTAs) is the lack of criteria for determining what represents unacceptable risk. In this study, we investigated the biological parameters in the laboratory and field population abundance of Nilaparvata lugens (Hemiptera: Delphacidae) on two Bt rice lines and the non-Bt parent, together with 14 other conventional rice cultivars. Significant difference were found in nymphal duration and fecundity of N. lugens fed on Bt rice KMD2, as well as field population density on 12 October, compared with non-Bt parent. However, compared with the variation among conventional rice cultivars, the variation of each parameter between Bt rice and the non-Bt parent was much smaller, which can be easily seen from low-high bar graphs and also the coefficient of variation value (C.V). The variation among conventional cultivars is proposed to be used as a criterion for the safety assessment of Bt rice on NTAs, particularly when statistically significant differences in several parameters are found between Bt rice and its non-Bt parent. Coefficient of variation is suggested as a promising parameter for ecological risk judgement of IRGM rice on NTAs.
Kang, Koung Mi; Choi, Seung Hong; Kim, Dong Eun; Yun, Tae Jin; Kim, Ji-Hoon; Sohn, Chul-Ho; Park, Sun-Won
2017-07-10
To prospectively evaluate whether cardiac gating can improve the reproducibility of intravoxel incoherent motion (IVIM) parameters in the head and neck, we performed IVIM diffusion-weighted imaging (DWI) using 4 b values (4b), 4 b values with cardiac gating (4b gating) and 17 b values (17b). We performed IVIM DWI twice per person on nine healthy volunteers using 4b, 4b gating and 17b and five patients with head and neck masses using 4b gating and 17b. The ADC, perfusion fraction (f), diffusion coefficient (D) and perfusion-related diffusion coefficient (D*) were calculated in the brain, masticator muscle, parotid gland, submandibular gland, tonsil and masses. Intraclass coefficient (ICC), Bland-Altman analysis (BAA) and coefficient of variation (CV) were used to assess short-term test-retest reproducibility. Kruskal-Wallis test and Mann-Whitney test were used to investigate whether 4b, 4b gating or 17b had significant influences on the parameters. For normal tissues and masses, ICC was excellent for all maps except the D* map. All parameters showed the lowest CV in the 4b gating. BAA also revealed the narrowest 95% limits of agreement using 4b gating for all parameters. In the subgroup analysis, almost all parameters in brain, muscle, parotid gland and submandibular gland showed the best reproducibility using 4b gating. In the muscle, parotid gland and submandibular gland, the values of ADC, f and D were not significantly different between among the three methods. 4b gating was more reproducible with respect to measurements of IVIM parameters in comparison with 4b or 17b.
Swimming Training Assessment: The Critical Velocity and the 400-m Test for Age-Group Swimmers.
Zacca, Rodrigo; Fernandes, Ricardo Jorge P; Pyne, David B; Castro, Flávio Antônio de S
2016-05-01
To verify the metabolic responses of oxygen consumption (V[Combining Dot Above]O2), heart rate (HR), blood lactate concentrations [La], and rate of perceived exertion (RPE) when swimming at an intensity corresponding to the critical velocity (CV) assessed by a 4-parameter model (CV4par), and to check the reliability when using only a single 400-m maximal front crawl bout (T400) for CV4par assessment in age-group swimmers. Ten age-group swimmers (14-16 years old) performed 50-, 100-, 200-, 400- (T400), 800-, and 1,500-m maximal front crawl bouts to calculate CV4par. V[Combining Dot Above]O2, HR, [La], and RPE were measured immediately after bouts. Swimmers then performed 3 × 10-minute front crawl (45 seconds rest) at CV4par. V[Combining Dot Above]O2, HR, [La], and RPE were measured after 10 minutes of rest (Rest), warm-up (Pre), each 10-minute repetition, and at the end of the test (Post). CV4par was 1.33 ± 0.08 m·s. V[Combining Dot Above]O2, HR, [La], and RPE were similar between first 10-minute and Post time points in the 3 × 10-minute protocol. CV4par was equivalent to 92 ± 2% of the mean swimming speed of T400 (v400) for these swimmers. CV4par calculated through a single T400 (92%v400) showed excellent agreement (r = 0.30; 95% CI: -0.04 to 0.05 m·s, p = 0.39), low coefficient of variation (2%), and root mean square error of 0.02 ± 0.01 m·s when plotted against CV4par assessed through a 4-parameter model. These results generated the equation CV4par = 0.92 × v400. A single T400 can be used reliably to estimate the CV4par typically derived with 6 efforts in age-group swimmers.
Panaite, Vanessa; Salomon, Kristen; Jin, Alvin; Rottenberg, Jonathan
2015-01-01
Objective Exaggerated cardiovascular (CV) reactivity to laboratory challenge has been shown to predict future CV morbidity and mortality. CV recovery, has been less studied, and has yielded inconsistent findings, possibly due to presence of moderators. Reviews on the relationship between CV recovery and CV outcomes have been limited to cross-sectional studies and have not considered methodological factors. We performed a comprehensive meta-analytic review of the prospective literature investigating CV recovery to physical and psychological challenge and adverse cardiovascular outcomes. Methods We searched PsycINFO and PubMed for prospective studies investigating the relationship between CV recovery and adverse CV outcomes. Studies were coded for variables of interest and for effect sizes (ES). We conducted a random effects weighted meta-analysis. Moderators were examined with ANOVA-analog and meta-regression analyses. Results Thirty seven studies met inclusion criteria (N=125386). Impaired recovery from challenge predicted adverse cardiovascular outcomes (summary effect, r = .17, p < .001). Physical challenge was associated with larger predictive effects than psychological challenge. Moderator analyses revealed that recovery measured at 1 minute post-exercise, passive recovery, use of mortality as an outcome measure, and older sample age were associated with larger effects. Conclusions Poor recovery from laboratory challenges predicts adverse CV outcomes, with recovery from exercise serving as a particularly strong predictor of CV outcomes. The overall ES for recovery and CV outcomes is similar to that observed for CV reactivity and suggests that the study of recovery may have incremental value for understanding adverse CV outcomes. PMID:25829236
Haeusler, Karl Georg; Wollboldt, Christian; Bentheim, Laura Zu; Herm, Juliane; Jäger, Sebastian; Kunze, Claudia; Eberle, Holger-Carsten; Deluigi, Claudia Christina; Bruder, Oliver; Malsch, Carolin; Heuschmann, Peter U; Endres, Matthias; Audebert, Heinrich J; Morguet, Andreas J; Jensen, Christoph; Fiebach, Jochen B
2017-05-01
Etiology of acute ischemic stroke remains undetermined (cryptogenic) in about 25% of patients after state-of-the-art diagnostic work-up. One-hundred and three patients with magnetic resonance imaging (MRI)-proven acute ischemic stroke of undetermined origin were prospectively enrolled and underwent 3-T cardiac MRI and magnetic resonance angiography of the aortic arch in addition to state-of-the-art diagnostic work-up, including transesophageal echocardiography (TEE). We analyzed the feasibility, diagnostic accuracy, and added value of cardiovascular MRI (cvMRI) compared with TEE for detecting sources of stroke. Overall, 102 (99.0%) ischemic stroke patients (median 63 years [interquartile range, 53-72], 24% female, median NIHSS (National Institutes of Health Stroke Scale) score on admission 2 [interquartile range, 1-4]) underwent cvMRI and TEE in hospital; 89 (86.4%) patients completed the cvMRI examination. In 93 cryptogenic stroke patients, a high-risk embolic source was found in 9 (8.7%) patients by cvMRI and in 11 (11.8%) patients by echocardiography, respectively. cvMRI and echocardiography findings were consistent in 80 (86.0%) patients, resulting in a degree of agreement of κ=0.24. In 82 patients with cryptogenic stroke according to routine work-up, including TEE, cvMRI identified stroke etiology in additional 5 (6.1%) patients. Late gadolinium enhancement consistent with previous myocardial infarction was found in 13 (14.6%) out of 89 stroke patients completing cvMRI. Only 2 of these 13 patients had known coronary artery disease. Our study demonstrated that cvMRI was feasible in the vast majority of included patients with acute ischemic stroke. The diagnostic information of cvMRI seems to be complementary to TEE but is not replacing echocardiography after acute ischemic stroke. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01917955. © 2017 American Heart Association, Inc.
Perino, Alexander C; Soofi, Muhammad; Singh, Nikhil; Aggarwal, Sonya; Froelicher, Victor
2015-01-01
We sought to characterize the prognostic value of the third universal definition of myocardial infarction (UDMI) and ≥40msec Q wave criteria. We evaluated hazard ratios (HR) with 95% confidence intervals (CI) for cardiovascular (CV) death for computerized Q wave measurements from the electrocardiograms of 43,661 patients collected from 1987 to 1999 at the Palo Alto VA. There were 3929 (9.0%) CV deaths over a mean follow-up of 7.6 (±3.8) years. The risk of CV death for Q waves ≥40msec in any two contiguous leads in any lead group was equivalent to or higher than that for contiguous UDMI Q waves, with HR 2.44 (95% CI 2.15-4.11) and HR 2.42 (95% CI (2.18-3.42), respectively. The UDMI Q wave criteria do not provide an advantage over ≥40msec Q waves at predicting CV death. Copyright © 2015. Published by Elsevier Inc.
Tembhare, Prashant; Badrinath, Yajamanam; Ghogale, Sitaram; Patkar, Nikhil; Dhole, Nilesh; Dalavi, Pooja; Kunder, Nikesh; Kumar, Ashok; Gujral, Sumeet; Subramanian, P G
2016-03-01
Abnormal DNA ploidy is a valuable prognostic factor in many neoplasms, especially in hematological neoplasms like B-cell acute lymphoblastic leukemia (B-ALL) and multiple myeloma (MM). Current methods of flow-cytometric (FC) DNA-ploidy evaluation are either technically difficult or limited to three- to four-color immunophenotyping and hence, challenging to evaluate DNA-ploidy in minute tumor population with background rich of its normal counterpart cells and other hematopoietic cells. We standardized a novel sensitive and easy method of simultaneous evaluation of six- to seven-color immunophenotyping and DNA-ploidy using a dye-FxCycle Violet (FCV). Linearity, resolution, and coefficient of variation (CV) for FCV were studied using chicken erythrocyte nuclei. Ploidy results of FCV were compared with Propidium iodide (PI) in 20 samples and intra-assay variation for FCV was studied. Using this six-color immunophenotyping & FCV-protocol DNA-ploidy was determined in bone-marrow samples from 124 B-ALL & 50 MM patients. Dilution experiment was also conducted to determine the sensitivity in detection of aneuploidy in minute tumor population. FCV revealed high linearity and resolution in 450/50 channel. On comparison with PI, CV of Go/G1-peak with FCV (mean-CV 4.1%) was slightly higher than PI (mean-CV 2.9%) but had complete agreement in ploidy results. Dilution experiment showed that aneuploidy could be accurately detected up to the limit of 0.01% tumor cells. Intra-assay variation was very low with CV of 0.005%. In B-ALL, hypodiploidy was noted in 4%, hyperdiploidy in 24%, near-hyperdiploidy in 13% and remaining 59% were diploid. In MM, hypodiploidy was in 2%, hyperdiploidy in 58%, near-hyperdiploidy in 8% and remaining 30% were diploid. FCV-based DNA-ploidy method is a sensitive and easy method for simultaneous evaluation of six-color immunophenotyping and DNA analysis. It is useful in DNA-ploidy evaluation of minute tumor population in cases like minimal residual disease and MM precursor conditions. © 2015 International Society for Advancement of Cytometry.
Sushames, Ashleigh; Edwards, Andrew; Thompson, Fintan; McDermott, Robyn; Gebel, Klaus
2016-01-01
Objectives To examine the validity and reliability of the Fitbit Flex against direct observation for measuring steps in the laboratory and against the Actigraph for step counts in free-living conditions and for moderate-to-vigorous physical activity (MVPA) and activity energy expenditure (AEE) overall. Methods Twenty-five adults (12 females, 13 males) wore a Fitbit Flex and an Actigraph GT3X+ during a laboratory based protocol (including walking, incline walking, running and stepping) and free-living conditions during a single day period to examine measurement of steps, AEE and MVPA. Twenty-four of the participants attended a second session using the same protocol. Results Intraclass correlations (ICC) for test-retest reliability of the Fitbit Flex were strong for walking (ICC = 0.57), moderate for stair stepping (ICC = 0.34), and weak for incline walking (ICC = 0.22) and jogging (ICC = 0.26). The Fitbit significantly undercounted walking steps in the laboratory (absolute proportional difference: 21.2%, 95%CI 13.0–29.4%), but it was more accurate, despite slightly over counting, for both jogging (6.4%, 95%CI 3.7–9.0%) and stair stepping (15.5%, 95%CI 10.1–20.9%). The Fitbit had higher coefficients of variation (Cv) for step counts compared to direct observation and the Actigraph. In free-living conditions, the average MVPA minutes were lower in the Fitbit (35.4 minutes) compared to the Actigraph (54.6 minutes), but AEE was greater from the Fitbit (808.1 calories) versus the Actigraph (538.9 calories). The coefficients of variation were similar for AEE for the Actigraph (Cv = 36.0) and Fitbit (Cv = 35.0), but lower in the Actigraph (Cv = 25.5) for MVPA against the Fitbit (Cv = 32.7). Conclusion The Fitbit Flex has moderate validity for measuring physical activity relative to direct observation and the Actigraph. Test-rest reliability of the Fitbit was dependant on activity type and had greater variation between sessions compared to the Actigraph. Physical activity surveillance studies using the Fitbit Flex should consider the potential effect of measurement reactivity and undercounting of steps. PMID:27589592
García-Ramos, Amador; Haff, G Gregory; Padial, Paulino; Feriche, Belén
2018-03-01
This study aimed to examine the reliability of different power and velocity variables during the Smith machine bench press (BP) and bench press throw (BPT) exercises. Twenty-two healthy men conducted four testing sessions after a preliminary BP one-repetition maximum (1RM) test. In a counterbalanced order, participants performed two sessions of BP in one week and two sessions of BPT in another week. Mean propulsive power, peak power, mean propulsive velocity, and peak velocity at each tenth percentile (20-70% of 1RM) were recorded by a linear transducer. The within-participants coefficient of variation (CV) was higher for the load-power relationship compared to the load-velocity relationship in both the BP (5.3% vs. 4.1%; CV ratio = 1.29) and BPT (4.7% vs. 3.4%; CV ratio = 1.38). Mean propulsive variables showed lower reliability than peak variables in both the BP (5.4% vs. 4.0%, CV ratio = 1.35) and BPT (4.8% vs. 3.3%, CV ratio = 1.45). All variables were deemed reliable, with the peak velocity demonstrating the lowest within-participants CV. Based upon these findings, the peak velocity should be chosen for the accurate assessment of BP and BPT performance.
Safety Analysis of X4 Multi-Tooled Iowa Detonator Loader
1980-10-01
D atmosphere. Temperature identification number should be T5.* Personnel Injury Resulting From Machine Incident - Due to the presence of the barricade...ling factor is the yield strength of velostat . 18 the expectancy is 6 x i0-15 accidents per facility hour. Although the spoon is made of phenolic...expression becoms: I- SF (C-2) v (Cv•cp) (xs) (CV,) 2- uthere: C - coefficient of v4riation for the proess ptent’.4 CV% c"of•iclent of variation "or
Chan, W; Gerhardt, G C; Salisbury, C D
1994-01-01
A method for the simultaneous determination of tylosin and tilmicosin residues in animal tissues is reported. Solid-phase extraction columns are used to isolate the drugs from tissue extracts. Determination is accomplished by reversed-phase liquid chromatography with UV detection at 287 nm. Mean recoveries from spiked tissues were 79.9% (coefficient of variation [CV], 8.1%) for tylosin and 92.6% (CV, 8.7%) for tilmicosin. Detection limits for tylosin and tilmicosin were 0.020 and 0.010 ppm, respectively.
A computer program for sample size computations for banding studies
Wilson, K.R.; Nichols, J.D.; Hines, J.E.
1989-01-01
Sample sizes necessary for estimating survival rates of banded birds, adults and young, are derived based on specified levels of precision. The banding study can be new or ongoing. The desired coefficient of variation (CV) for annual survival estimates, the CV for mean annual survival estimates, and the length of the study must be specified to compute sample sizes. A computer program is available for computation of the sample sizes, and a description of the input and output is provided.
Troxler, Renaud; Minoiu, Costin; Vaucher, Paul; Michaud, Katarzyna; Doenz, Francesco; Ducrot, Kewin; Grabherr, Silke
2018-01-01
Postmortem CT angiography is the method of choice for the postmortem imaging investigations of the cardiovascular (CV) system. However, autopsy still remains the gold standard for CV measurement. Nevertheless, there are not any studies on CV measurements on the multi-phase postmortem angiography (MPMCTA) which includes comparisons with autopsy. Therefore, the aim of this study is to compare CV measurements between the native CT scan and the three phases of the MPMCTA to find out which of these modalities correlate the best with autopsy measurements. For this study, we selected retrospectively 50 postmortem cases that underwent both MPMCTA and autopsy. A comparison was carried out between the CV measurements obtained with imaging (aorta; heart cavities and cardiac wall thicknesses; maximum cardiac diameter and cardiothoracic ratio) and at the autopsy (aorta; cardiac valves, ventricular thicknesses, and weight). Our results show that the dynamic phase displays an advantage for the measurement of the aortas. However, the MPMCTA is not accurate to measure the cardiac wall thicknesses. The measurements of the heart cavities show no correlation with the heart valves. The cardiothoracic ratio measured by the MPMCTA shows no correlation with the heart weight. Nevertheless, the maximum cardiac diameter exhibits a correlation with the latter on the venous and dynamic phase. These results show that only few CV parameters measured with imaging correlate with measurement obtained at the autopsy. These results indicate that in order to better estimate values obtained at the autopsy, we need to define new reference values for the CV measurement on MPMCTA.
Olsen, Mia B.; Wielandt, Daniel; Schiller, Martin; Van Kooten, Elishevah M.M.E.; Bizzarro, Martin
2016-01-01
We report on the petrology, magnesium isotopes and mass-independent 54Cr/52Cr compositions (μ54Cr) of 42 chondrules from CV (Vigarano and NWA 3118) and CR (NWA 6043, NWA 801 and LAP 02342) chondrites. All sampled chondrules are classified as type IA or type IAB, have low 27Al/24Mg ratios (0.04–0.27) and display little or no evidence for secondary alteration processes. The CV and CR chondrules show variable 25Mg/24Mg and 26Mg/24Mg values corresponding to a range of mass-dependent fractionation of ~500 ppm (parts per million) per atomic mass unit. This mass-dependent Mg isotope fractionation is interpreted as reflecting Mg isotope heterogeneity of the chondrule precursors and not the result of secondary alteration or volatility-controlled processes during chondrule formation. The CV and CR chondrule populations studied here are characterized by systematic deficits in the mass-independent component of 26Mg (μ26Mg*) relative to the solar value defined by CI chondrites, which we interpret as reflecting formation from precursor material with a reduced initial abundance of 26Al compared to the canonical 26Al/27Al of ~5 × 10−5. Model initial 26Al/27Al values of CV and CR chondrules vary from (1.5 ± 4.0) × 10−6 to (2.2 ± 0.4) × 10−5. The CV chondrules display significant μ54Cr variability, defining a range of compositions that is comparable to that observed for inner Solar System primitive and differentiated meteorites. In contrast, CR chondrites are characterized by a narrower range of μ54Cr values restricted to compositions typically observed for bulk carbonaceous chondrites. Collectively, these observations suggest that the CV chondrules formed from precursors that originated in various regions of the protoplanetary disk and were then transported to the accretion region of the CV parent asteroid whereas CR chondrule predominantly formed from precursor with carbonaceous chondrite-like μ54Cr signatures. The observed μ54Cr variability in chondrules from CV and CR chondrites suggest that the matrix and chondrules did not necessarily formed from the same reservoir. The coupled μ26Mg* and μ54Cr systematics of CR chondrules establishes that these objects formed from a thermally unprocessed and 26Al-poor source reservoir distinct from most inner Solar System asteroids and planetary bodies, possibly located beyond the orbits of the gas giants. In contrast, a large fraction of the CV chondrules plot on the inner Solar System correlation line, indicating that these objects predominantly formed from thermally-processed, 26Al-bearing precursor material akin to that of inner Solar System solids, asteroids and planets. PMID:27563152
NASA Astrophysics Data System (ADS)
Olsen, Mia B.; Wielandt, Daniel; Schiller, Martin; Van Kooten, Elishevah M. M. E.; Bizzarro, Martin
2016-10-01
We report on the petrology, magnesium isotopes and mass-independent 54Cr/52Cr compositions (μ54Cr) of 42 chondrules from CV (Vigarano and NWA 3118) and CR (NWA 6043, NWA 801 and LAP 02342) chondrites. All sampled chondrules are classified as type IA or type IAB, have low 27Al/24Mg ratios (0.04-0.27) and display little or no evidence for secondary alteration processes. The CV and CR chondrules show variable 25Mg/24Mg and 26Mg/24Mg values corresponding to a range of mass-dependent fractionation of ∼500 ppm (parts per million) per atomic mass unit. This mass-dependent Mg isotope fractionation is interpreted as reflecting Mg isotope heterogeneity of the chondrule precursors and not the result of secondary alteration or volatility-controlled processes during chondrule formation. The CV and CR chondrule populations studied here are characterized by systematic deficits in the mass-independent component of 26Mg (μ26Mg∗) relative to the solar value defined by CI chondrites, which we interpret as reflecting formation from precursor material with a reduced initial abundance of 26Al compared to the canonical 26Al/27Al of ∼5 × 10-5. Model initial 26Al/27Al values of CV and CR chondrules vary from (1.5 ± 4.0) × 10-6 to (2.2 ± 0.4) × 10-5. The CV chondrules display significant μ54Cr variability, defining a range of compositions that is comparable to that observed for inner Solar System primitive and differentiated meteorites. In contrast, CR chondrites are characterized by a narrower range of μ54Cr values restricted to compositions typically observed for bulk carbonaceous chondrites. Collectively, these observations suggest that the CV chondrules formed from precursors that originated in various regions of the protoplanetary disk and were then transported to the accretion region of the CV parent asteroid whereas CR chondrule predominantly formed from precursor with carbonaceous chondrite-like μ54Cr signatures. The observed μ54Cr variability in chondrules from CV and CR chondrites suggest that the matrix and chondrules did not necessarily formed from the same reservoir. The coupled μ26Mg∗ and μ54Cr systematics of CR chondrules establishes that these objects formed from a thermally unprocessed and 26Al-poor source reservoir distinct from most inner Solar System asteroids and planetary bodies, possibly located beyond the orbits of the gas giants. In contrast, a large fraction of the CV chondrules plot on the inner Solar System correlation line, indicating that these objects predominantly formed from thermally-processed, 26Al-bearing precursor material akin to that of inner Solar System solids, asteroids and planets.
TH-A-BRF-11: Image Intensity Non-Uniformities Between MRI Simulation and Diagnostic MRI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paulson, E
2014-06-15
Purpose: MRI simulation for MRI-based radiotherapy demands that patients be setup in treatment position, which frequently involves use of alternative radiofrequency (RF) coil configurations to accommodate immobilized patients. However, alternative RF coil geometries may exacerbate image intensity non-uniformities (IINU) beyond those observed in diagnostic MRI, which may challenge image segmentation and registration accuracy as well as confound studies assessing radiotherapy response when MR simulation images are used as baselines for evaluation. The goal of this work was to determine whether differences in IINU exist between MR simulation and diagnostic MR images. Methods: ACR-MRI phantom images were acquired at 3T usingmore » a spin-echo sequence (TE/TR:20/500ms, rBW:62.5kHz, TH/skip:5/5mm). MR simulation images were obtained by wrapping two flexible phased-array RF coils around the phantom. Diagnostic MR images were obtained by placing the phantom into a commercial phased-array head coil. Pre-scan normalization was enabled in both cases. Images were transferred offline and corrected for IINU using the MNI N3 algorithm. Coefficients of variation (CV=σ/μ) were calculated for each slice. Wilcoxon matched-pairs and Mann-Whitney tests compared CV values between original and N3 images and between MR simulation and diagnostic MR images. Results: Significant differences in CV were detected between original and N3 images in both MRI simulation and diagnostic MRI groups (p=0.010, p=0.010). In addition, significant differences in CV were detected between original MR simulation and original and N3 diagnostic MR images (p=0.0256, p=0.0016). However, no significant differences in CV were detected between N3 MR simulation images and original or N3 diagnostic MR images, demonstrating the importance of correcting MR simulation images beyond pre-scan normalization prior to use in radiotherapy. Conclusions: Alternative RF coil configurations used in MRI simulation can Result in significant IINU differences compared to diagnostic MR images. The MNI N3 algorithm reduced MR simulation IINU to levels observed in diagnostic MR images. Funding provided by Advancing a Healthier Wisconsin.« less
Measurement of methionine level with the LC-ESI-MS/MS method in schizophrenic patients.
Kulaksizoglu, S; Kulaksizoglu, B; Ellidag, H Y; Eren, E; Yilmaz, N; Baykal, A
2016-01-01
The purpose of this study was to evaluate plasma methionine levels by using liquid chromatography electrospray ionization-tandem mass spectroscopy (LC-ESI-MS/MS) in schizophrenic patients. A twelve-point standard graph was drawn, and the recovery rate, the intra-day and inter-day coefficients of variation (CV), the limit of detection (LOD), and the limit of quantification (LOQ) were evaluated. The y and R2 values of the standard graph equation were determined as 0.011x + 0.0179 and 0.9989, respectively, and the graph remained linear until the 200 µmol/l level. The intra-day coefficients of variation of the samples (n = 10) containing 8, 28, and 58 µmol/l methionine were determined as 2.68, 3.10, and 3.79%, respectively; while their inter-day coefficients of variation were determined as 2.98, 3.19, and 3.84%. The LOD and LOQ values were determined as 0.04 and 0.1 µmol/l, respectively, while the mean recovery rates were determined as 101.7 and 99.3%. Plasma methionine values were measured as 21.5 (19.5-24,6) µmol/l for the patient group, 17.8 (16.3-20.1) µmol/l for the control group, and the difference between the two groups was statistically significant (p = 0.03). LC-ESI-MS/MS method represents a fairly sensitive, economic, and rapid analysis that requires very little sample and is suitable for measuring methionine levels in schizophrenic patients.
2011-01-01
Background Hydroxyurea (HU) is the first approved pharmacological treatment of sickle cell anemia (SCA). The objectives of this study were to develop population pharmacokinetic(PK)-pharmacodynamic(PD) models for HU in order to characterize the exposure-efficacy relationships and their variability, compare two dosing regimens by simulations and develop some recommendations for monitoring the treatment. Methods The models were built using population modelling software NONMEM VII based on data from two clinical studies of SCA adult patients receiving 500-2000 mg of HU once daily. Fetal hemoglobin percentage (HbF%) and mean corpuscular volume (MCV) were used as biomarkers for response. A sequential modelling approach was applied. Models were evaluated using simulation-based techniques. Comparisons of two dosing regimens were performed by simulating 10000 patients in each arm during 12 months. Results The PK profiles were described by a bicompartmental model. The median (and interindividual coefficient of variation (CV)) of clearance was 11.6 L/h (30%), the central volume was 45.3 L (35%). PK steady-state was reached in about 35 days. For a given dosing regimen, HU exposure varied approximately fivefold among patients. The dynamics of HbF% and MCV were described by turnover models with inhibition of elimination of response. In the studied range of drug exposures, the effect of HU on HbF% was at its maximum (median Imax was 0.57, CV was 27%); the effect on MCV was close to its maximum, with median value of 0.14 and CV of 49%. Simulations showed that 95% of the steady-state levels of HbF% and MCV need 26 months and 3 months to be reached, respectively. The CV of the steady-state value of HbF% was about 7 times larger than that of MCV. Simulations with two different dosing regimens showed that continuous dosing led to a stronger HbF% increase in some patients. Conclusions The high variability of response to HU was related in part to pharmacokinetics and to pharmacodynamics. The steady-state value of MCV at month 3 is not predictive of the HbF% value at month 26. Hence, HbF% level may be a better biomarker for monitoring HU treatment. Continuous dosing might be more advantageous in terms of HbF% for patients who have a strong response to HU. Trial Registration The clinical studies whose data are analysed and reported in this work were not required to be registered in France at their time. Both studies were approved by local ethics committees (of Mondor Hospital and of Kremlin-Bicetre Hospital) and written informed consent was obtained from each patient. PMID:21619673
IVIM diffusion-weighted imaging of the liver at 3.0 T: Comparison with 1.5 T
Cui, Yong; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Taouli, Bachir
2015-01-01
Purpose To compare intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver between 1.5 T and 3.0 T in terms of parameter quantification and inter-platform reproducibility. Materials and methods In this IRB approved prospective study, 19 subjects (17 patients with chronic liver disease and 2 healthy volunteers) underwent two repeat scans at 1.5 T and 3.0 T. Each scan included IVIM DWI using 16 b values from 0 to 800 s/mm2. A single observer measured IVIM parameters for each platform and estimated signal to noise ratio (eSNR) at b0, 200, 400 and 800 s/mm2. Wilcoxon paired tests were used to compare liver eSNR and IVIM parameters. Inter-platform reproducibility was assessed by calculating within-subject coefficient of variation (CV) and Bland–Altman limits of agreement. An ice water phantom was used to test ADC variability between the two MRI systems. Results The mean invitro difference in ADC between the two platforms was 6.8%. eSNR was significantly higher at 3.0T for all selected b values (p = 0.006–0.020), except for b0 (p = 0.239). Liver IVIM parameters were significantly different between 1.5 T and 3.0 T (p = 0.005–0.044), except for ADC (p = 0.748). The inter-platform reproducibility of true diffusion coefficient (D) and ADC were good, with mean CV of 10.9% and 11.1%, respectively. Perfusion fraction (PF) and pseudodiffusion coefficient (D*) showed more limited inter-platform reproducibility (mean CV of 22.6% for PF and 46.9% for D*). Conclusion Liver D and ADC values showed good reproducibility between 1.5 T and 3.0 T platforms; while there was more variability in PF, and large variability in D* parameters between the two platforms. These findings may have implications for drug trials assessing the role of IVIM DWI in tumor response and liver fibrosis. PMID:26393236
Population Modeling Approach to Optimize Crop Harvest Strategy. The Case of Field Tomato.
Tran, Dinh T; Hertog, Maarten L A T M; Tran, Thi L H; Quyen, Nguyen T; Van de Poel, Bram; Mata, Clara I; Nicolaï, Bart M
2017-01-01
In this study, the aim is to develop a population model based approach to optimize fruit harvesting strategies with regard to fruit quality and its derived economic value. This approach was applied to the case of tomato fruit harvesting under Vietnamese conditions. Fruit growth and development of tomato (cv. "Savior") was monitored in terms of fruit size and color during both the Vietnamese winter and summer growing seasons. A kinetic tomato fruit growth model was applied to quantify biological fruit-to-fruit variation in terms of their physiological maturation. This model was successfully calibrated. Finally, the model was extended to translate the fruit-to-fruit variation at harvest into the economic value of the harvested crop. It can be concluded that a model based approach to the optimization of harvest date and harvest frequency with regard to economic value of the crop as such is feasible. This approach allows growers to optimize their harvesting strategy by harvesting the crop at more uniform maturity stages meeting the stringent retail demands for homogeneous high quality product. The total farm profit would still depend on the impact a change in harvesting strategy might have on related expenditures. This model based harvest optimisation approach can be easily transferred to other fruit and vegetable crops improving homogeneity of the postharvest product streams.
Calvo-Bonacho, Eva; Ruilope, Luis Miguel; Sánchez-Chaparro, Miguel Angel; Cerezo, Cesar; Catalina-Romero, Carlos; Martínez-Muñoz, Paloma; Banegas, José R; Waeber, Bernard; Gonzalez-Quintela, Arturo; Zanchetti, Alberto
2014-02-01
We investigated the potential influence of a moderate-to-high cardiovascular (CV) risk (CVR) (defined as a Systematic COronary Risk Evaluation model, or SCORE ≥ 4%), in the absence of an established CV disease, on the duration and cost of CV and non-CV sick leave (SL) resulting from common and occupational accidents or diseases. We conducted a prospective cohort study on 690 135 workers with a 1-year follow-up and examined CV- and non-CV-related SL episodes. To obtain baseline values, CVR factors were initially assessed at the beginning of the year during routine medical examination. The CVR was calculated with the SCORE charts for all subjects. Moderate-to-high CVR was defined as SCORE ≥ 4%. A baseline SCORE ≥ 4% was associated with a higher risk for long-term CV and non-CV SL, as revealed by follow-up assessment. This translated into an increased cost, estimated at €5 801 464.18 per year. Furthermore, pharmacological treatment for hypertension or hyperlipidaemia was significantly associated with longer SL duration. Moderate-to-high CVR in asymptomatic subjects was significantly associated with the duration and cost of CV and non-CV SL. These results constitute the first body of evidence that the SCORE charts can be used to identify people with a non-established CV disease, which might ultimately translate into more lost workdays and therefore increased cost for society.
Fencl, Pavel; Belohlavek, Otakar; Harustiak, Tomas; Zemanova, Milada
2012-11-01
When applying the PET Response Criteria in Solid Tumors protocol, a threshold value based on standardized uptake value corrected to lean body mass (SUL) in liver parenchyma, or in the blood pool, is used: to metabolically specify a measurable lesion; to calculate metabolic tumor volume (mTV) and its product total lesion glycolysis (TLG); and as a limit for response measurement. The problem with using changes in glucose metabolism as a marker for response to therapy is its reproducibility on test-retest examinations. Therefore, before the evaluation of tumor treatment response, we verified our diagnostic protocol for homogeneity using the PET Response Criteria in Solid Tumors quality parameters. In addition, we analyzed the effect of the time span between examinations on the average value of SUL (SUL MEAN) in liver parenchyma at three different points: first at baseline (BL), after the first course of chemotherapy (ChT1), and finally after finishing therapy (ChT3). We also analyzed the influence of SUL MEAN variation on mTV and TLG. Eighty-four patients with esophageal cancer were prospectively examined at BL using 2-deoxy-2-[18F]fluoro-D-glucose (18F-FDG)-PET/CT; 53 of 84 patients were examined after ChT1, 47 of 84 after ChT3, and 41 of 84 underwent all three examinations. Coefficient of variance (CV) and relative differences (RDw) were assessed for test-retest liver SUL values. The influence of liver SUL MEAN to mTV and TLG was modeled on BL examinations by artificial changes in liver SUL MEAN by ± 20%. No significant differences were found in test-retest liver SUL MEAN values. Comparing BL with ChT1, BL with ChT3, and ChT1 with ChT3, the CV of the liver SUL MEAN was 10.4, 10.7, and 10.3%; nevertheless, in 34.0, 38.3, and 36.6% of these examinations, respectively, the liver average SUL MEAN values exceeded the limit for inclusion in the study; that is, the difference was less than ± 0.3 U and ± 20%. The corresponding CV of blood background was 14.9, 16.5, and 17.2%. The artificial decrease of -20% in the liver SUL MEAN resulted in an increase of +43.6% in mTV and of +20.4% in TLG, whereas an increase of +20% in the liver SUL MEAN resulted in a decrease of -20.6% in mTV and -11.9% in TLG. SUL MEAN values in reference tissues (liver parenchyma or descending aorta) measured before chemotherapy did not differ significantly from those measured during chemotherapy. The CV of liver SUL MEAN was comparable to that seen in published data, but some patients had to be excluded from the study because of the individual variability of their mean liver SUL MEAN, which consequently hinders the clinical usage of mTV and TLG. Even in the standardized protocol, all potential sources of variability should be minimized.
Yuan, Feng-Hui; Guan, De-Xin; Wu, Jia-Bing; Wang, An-Zhi; Shi, Ting-Ting; Zhang, Xiao-Jing
2008-02-01
Based on the data of three years successive automatic measurement with five horizontal quantum PAR sensors, this paper studied the spatiotemporal characteristics of photosynthetically active radiation (PAR) in the understory of Korean pine and broadleaved mixed forest in Changbai Mountains, in contrast with above-canopy PAR. It was found that the annual dynamics of above-canopy PAR showed two or more peaks, which was mainly affected by the weather conditions such as cloudy, foggy and rainy events. The annual dynamics of understory PAR followed the same trend of above-canopy PAR in non-growth season, but was steady and lower in numerical value in growth season. On clear days, larger differences were observed in the diurnal variation and frequency distribution of the understory PAR. As for the spatial variation of the understory PAR, the coefficient of variation (CV) was smaller in non-growth season (about 0.15) than in growth season (> 0.22), with the greatest in August. On the clear days in growth season, the understory PAR had a greater spatial variation when the solar elevation angle was between 38 degrees and 48 degrees (at 9:00-10:00 or 13:00-14:00).
Wiesinger, Hans-Peter; Wiemer, Nicolas; Kösters, Alexander; Müller, Erich
2016-01-01
Abstract The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48–72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTDpeak) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0–30 to 0–300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTDpeak (version II). High ICC-values (0.80–0.99) and acceptable CV-values (1.9–8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTDpeak as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse0–30ms and RTD/impulse0–50ms) showed clearly weaker reproducibility results (ICC: 0.53–0.84; CV: 7.3–16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTDpeak-trial. PMID:28149337
Gergei, Ingrid; Krämer, Bernhard K; Scharnagl, Hubert; Stojakovic, Tatjana; März, Winfried; Mondorf, Ulrich
The endothelin system (Big-ET-1) is a key regulator in cardiovascular (CV) disease and congestive heart failure (CHF). We have examined the incremental value of Big-ET-1 in predicting total and CV mortality next to the well-established CV risk marker N-Terminal Pro-B-Type Natriuretic Peptide (NT-proBNP). Big-ET-1 and NT-proBNP were determined in 2829 participants referred for coronary angiography (follow-up 9.9 years). Big-ET-1 is an independent predictor of total, CV mortality and death due to CHF. The conjunct use of Big-ET-1 and NT-proBNP improves the risk stratification of patients with intermediate to high risk of CV death and CHF. Big-ET-1improves risk stratification in patients referred for coronary angiography.
2010-01-01
Introduction Central venous oxygen saturation (ScvO2) is a useful therapeutic target in septic shock and high-risk surgery. We tested the hypothesis that central venous-to-arterial carbon dioxide difference (P(cv-a)CO2), a global index of tissue perfusion, could be used as a complementary tool to ScvO2 for goal-directed fluid therapy (GDT) to identify persistent low flow after optimization of preload has been achieved by fluid loading during high-risk surgery. Methods This is a secondary analysis of results obtained in a study involving 70 adult patients (ASA I to III), undergoing major abdominal surgery, and treated with an individualized goal-directed fluid replacement therapy. All patients were managed to maintain a respiratory variation in peak aortic flow velocity below 13%. Cardiac index (CI), oxygen delivery index (DO2i), ScvO2, P(cv-a)CO2 and postoperative complications were recorded blindly for all patients. Results A total of 34% of patients developed postoperative complications. At baseline, there was no difference in demographic or haemodynamic variables between patients who developed complications and those who did not. In patients with complications, during surgery, both mean ScvO2 (78 ± 4 versus 81 ± 4%, P = 0.017) and minimal ScvO2 (minScvO2) (67 ± 6 versus 72 ± 6%, P = 0.0017) were lower than in patients without complications, despite perfusion of similar volumes of fluids and comparable CI and DO2i values. The optimal ScvO2 cut-off value was 70.6% and minScvO2 < 70% was independently associated with the development of postoperative complications (OR = 4.2 (95% CI: 1.1 to 14.4), P = 0.025). P(cv-a)CO2 was larger in patients with complications (7.8 ± 2 versus 5.6 ± 2 mmHg, P < 10-6). In patients with complications and ScvO2 ≥71%, P(cv-a)CO2 was also significantly larger (7.7 ± 2 versus 5.5 ± 2 mmHg, P < 10-6) than in patients without complications. The area under the receiver operating characteristic (ROC) curve was 0.785 (95% CI: 0.74 to 0.83) for discrimination of patients with ScvO2 ≥71% who did and did not develop complications, with 5 mmHg as the most predictive threshold value. Conclusions ScvO2 reflects important changes in O2 delivery in relation to O2 needs during the perioperative period. A P(cv-a)CO2 < 5 mmHg might serve as a complementary target to ScvO2 during GDT to identify persistent inadequacy of the circulatory response in face of metabolic requirements when an ScvO2 ≥71% is achieved. Trial registration Clinicaltrials.gov Identifier: NCT00852449. PMID:21034476
Fully moderated T-statistic for small sample size gene expression arrays.
Yu, Lianbo; Gulati, Parul; Fernandez, Soledad; Pennell, Michael; Kirschner, Lawrence; Jarjoura, David
2011-09-15
Gene expression microarray experiments with few replications lead to great variability in estimates of gene variances. Several Bayesian methods have been developed to reduce this variability and to increase power. Thus far, moderated t methods assumed a constant coefficient of variation (CV) for the gene variances. We provide evidence against this assumption, and extend the method by allowing the CV to vary with gene expression. Our CV varying method, which we refer to as the fully moderated t-statistic, was compared to three other methods (ordinary t, and two moderated t predecessors). A simulation study and a familiar spike-in data set were used to assess the performance of the testing methods. The results showed that our CV varying method had higher power than the other three methods, identified a greater number of true positives in spike-in data, fit simulated data under varying assumptions very well, and in a real data set better identified higher expressing genes that were consistent with functional pathways associated with the experiments.
Functional characterization of contractile vacuole isolated from Amoeba proteus.
Nishihara, Eri; Shimmen, Teruo; Sonobe, Seiji
2004-12-01
Contractile vacuoles (CVs) released from cells of Amoeba proteus were used to analyze its function in vitro. When CV was transferred to a hypertonic medium, its volume decreased within 10 sec. When it was subsequently returned to its original medium, it quickly started swelling. However, it ruptured before recovering its initial volume. These results suggested that the CV membrane is semi-permeable and that the fluid is collected by the osmotic gradient in vivo. The water permeability of membrane of isolated CV was calculated from the rate of osmotic volume change to be 0.94 microm/sec . OsM. This high value suggested that CV membrane is equipped with water channel. CV contracted (or burst) quickly upon addition of 1 mM ATP. Contraction was induced by ATP, but not by other nucleotides, GTP, ITP, ADP, or the analogues of ATP, AMP-PNP and ATPgammaS. It was suggested that the contraction of isolated CV was caused by increase in the tension of its membrane by ATP.
Ehlenfeldt, M K; Prior, R L
2001-05-01
Antioxidant capacity, as measured by oxygen radical absorbance capacity (ORAC), and total phenolic and total anthocyanin contents were evaluated in fruit tissues of 87 highbush blueberry (Vacciniumcorymbosum L.) and species-introgressed highbush blueberry cultivars. ORAC and phenolic levels were evaluated in leaf tissues of the same materials. Average values for ORAC, phenolics, and anthocyanins in fruit were 15.9 ORAC units, 1.79 mg/g (gallic acid equivalents), and 0.95 mg/g (cyanidin-3-glucoside equivalents), respectively. Cv. Rubel had the highest ORAC per gram of fresh weight values, at 31.1 units, and cv. Elliott had the highest values on the basis of ORAC per square centimeter of surface area. In leaf tissue, values for both ORAC and phenolics were significantly higher than in fruit tissue, with mean values of 490 ORAC units and 44.80 mg/g (gallic acid equivalents), respectively. Leaf ORAC had a low, but significant, correlation with fruit phenolics and anthocyanins, but not with fruit ORAC. An analysis of ORAC values versus calculated midparent values in 11 plants from the 87-cultivar group in which all parents were tested suggested that, across cultivars, ORAC inheritance is additive. An investigation of ORAC values in a family of 44 cv. Rubel x Duke seedlings showed negative epistasis for ORAC values, suggesting Rubel may have gene combinations contributing to ORAC that are broken up during hybridization.
Accuracy and precision of stream reach water surface slopes estimated in the field and from maps
Isaak, D.J.; Hubert, W.A.; Krueger, K.L.
1999-01-01
The accuracy and precision of five tools used to measure stream water surface slope (WSS) were evaluated. Water surface slopes estimated in the field with a clinometer or from topographic maps used in conjunction with a map wheel or geographic information system (GIS) were significantly higher than WSS estimated in the field with a surveying level (biases of 34, 41, and 53%, respectively). Accuracy of WSS estimates obtained with an Abney level did not differ from surveying level estimates, but conclusions regarding the accuracy of Abney levels and clinometers were weakened by intratool variability. The surveying level estimated WSS most precisely (coefficient of variation [CV] = 0.26%), followed by the GIS (CV = 1.87%), map wheel (CV = 6.18%), Abney level (CV = 13.68%), and clinometer (CV = 21.57%). Estimates of WSS measured in the field with an Abney level and estimated for the same reaches with a GIS used in conjunction with l:24,000-scale topographic maps were significantly correlated (r = 0.86), but there was a tendency for the GIS to overestimate WSS. Detailed accounts of the methods used to measure WSS and recommendations regarding the measurement of WSS are provided.
Age, gender, and skeletal variation in bone marrow composition: a preliminary study at 3.0 Tesla.
Liney, Gary P; Bernard, Clare P; Manton, David J; Turnbull, Lindsay W; Langton, Chris M
2007-09-01
To evaluate the efficacy of MR Spectroscopy (MRS) at 3.0 Tesla for the assessment of normal bone marrow composition and assess the variation in terms of age, gender, and skeletal site. A total of 16 normal subjects (aged between eight and 57 years) were investigated on a 3.0 Tesla GE Signa system. To investigate axial and peripheral skeleton differences, non-water-suppressed spectra were acquired from single voxels in the calcaneus and lumbar spine. In addition, spectra were acquired at multiple vertebral bodies to assess variation within the lumbar spine. Data was also correlated with bone mineral density (BMD) measured in six subjects using dual-energy X-ray absorptiometry (DXA). Fat content was an order of magnitude greater in the heel compared to the spine. An age-related increase was demonstrated in the spine with values greater in men compared to female subjects. Significant trends in vertebral bodies within the same subjects were also shown, with fat content increasing L5 > L1. Population coefficient of variation (CV) was greater for fat fraction (FF) compared to BMD. Significant normal variations of marrow composition have been demonstrated, which provide important data for the future interpretation of patient investigations. (c) 2007 Wiley-Liss, Inc.
Impact of post-processing methods on apparent diffusion coefficient values.
Zeilinger, Martin Georg; Lell, Michael; Baltzer, Pascal Andreas Thomas; Dörfler, Arnd; Uder, Michael; Dietzel, Matthias
2017-03-01
The apparent diffusion coefficient (ADC) is increasingly used as a quantitative biomarker in oncological imaging. ADC calculation is based on raw diffusion-weighted imaging (DWI) data, and multiple post-processing methods (PPMs) have been proposed for this purpose. We investigated whether PPM has an impact on final ADC values. Sixty-five lesions scanned with a standardized whole-body DWI-protocol at 3 T served as input data (EPI-DWI, b-values: 50, 400 and 800 s/mm 2 ). Using exactly the same ROI coordinates, four different PPM (ADC_1-ADC_4) were executed to calculate corresponding ADC values, given as [10 -3 mm 2 /s] of each lesion. Statistical analysis was performed to intra-individually compare ADC values stratified by PPM (Wilcoxon signed-rank tests: α = 1 %; descriptive statistics; relative difference/∆; coefficient of variation/CV). Stratified by PPM, mean ADCs ranged from 1.136-1.206 *10 -3 mm 2 /s (∆ = 7.0 %). Variances between PPM were pronounced in the upper range of ADC values (maximum: 2.540-2.763 10 -3 mm 2 /s, ∆ = 8 %). Pairwise comparisons identified significant differences between all PPM (P ≤ 0.003; mean CV = 7.2 %) and reached 0.137 *10 -3 mm 2 /s within the 25th-75th percentile. Altering the PPM had a significant impact on the ADC value. This should be considered if ADC values from different post-processing methods are compared in patient studies. • Post-processing methods significantly influenced ADC values. • The mean coefficient of ADC variation due to PPM was 7.2 %. • To achieve reproducible ADC values, standardization of post-processing is recommended.
Papademetriou, Vasilios; Lovato, Laura; Tsioufis, Costas; Cushman, William; Applegate, William B; Mottle, Amy; Punthakee, Zubin; Nylen, Eric; Doumas, Michael
2017-01-01
The role of high density lipoprotein-raising interventions in addition to statin therapy in patients with diabetes remains controversial. Chronic kidney disease (CKD) is a strong modifier of cardiovascular (CV) outcomes. We therefore investigated the impact of CKD status at baseline on outcomes in patients with diabetes randomized to standard statin or statin plus fenofibrate treatment in the Action to Control Cardiovascular Risk in Diabetes (ACCORD) lipid trial. Among 5,464 participants in the ACCORD lipid trial, 3,554 (65%) were free of CKD at baseline, while 1,910 (35%) had mild to moderate CKD. Differences in CV outcomes during follow-up between CKD and non-CKD subgroups were examined. In addition, the effect of fenofibrate as compared to placebo on CV outcomes was examined for both subgroups. All CV outcomes were 1.4-3 times higher among patients with CKD as compared to non-CKD patients. In patients with CKD, the addition of fenofibrate had no effect on any of the primary or secondary outcomes. In patients without CKD, however, the addition of fenofibrate was associated with a significant 36% reduction of CV mortality (hazards ratio [HR] 0.64; 95% CI 0.42-0.97; p value for treatment interaction <0.05) and 44% lower rate of fatal or non-fatal congestive heart failure (CHF; HR 0.56; 95% CI 0.37-0.84; p value treatment interaction <0.03). For patients with type 2 diabetes at high CV risk but no CKD, fenofibrate therapy added to statin reduced the CV mortality and the rate of fatal and non-fatal CHF. © 2016 S. Karger AG, Basel.
Diurnal Variations in Photosynthetic Products and Nitrogen Metabolism in Expanding Leaves
Steer, Barrie T.
1973-01-01
Expanding leaves of Capsicum frutescens L. cv. California Wonder, Cucumis melo L. cv. Hales Best, and Citrus sinensis L. Osbeck cv. Washington Navel showed a marked diurnal periodicity in the incorporation of 14C from photosynthetically fixed 14CO2 into amino acids. Incorporation was virtually nil at the beginning of the photoperiod, reached a maximum in the 6th to 7th hour and decreased during the latter part of the photoperiod. In Capsicum frutescens this was apparently a reflection of the availability of reduced nitrogen controlled by the activity of nitrate reductase in the leaves. This also controlled the periodicity of the incorporation of 14C into fraction I protein. Possible control mechanisms and the relation of nitrogen metabolism to the periodicity of leaf expansion growth are discussed. PMID:16658402
Clauser, Paola; Marcon, Magda; Maieron, Marta; Zuiani, Chiara; Bazzocchi, Massimo; Baltzer, Pascal A T
2016-07-01
To evaluate the influence of post-processing systems, intra- and inter-reader agreement on the variability of apparent diffusion coefficient (ADC) measurements in breast lesions. Forty-one patients with 41 biopsy-proven breast lesions gave their informed consent and were included in this prospective IRB-approved study. Magnetic resonance imaging (MRI) examinations were performed at 1.5 T using an EPI-DWI sequence, with b-values of 0 and 1000 s/mm(2). Two radiologists (R1, R2) reviewed the images in separate sessions and measured the ADC for lesion, using MRI-workstation (S-WS), PACS-workstation (P-WS) and a commercial DICOM viewer (O-SW). Agreement was evaluated using the intraclass correlation coefficient (ICC), Bland-Altman plots and coefficient of variation (CV). Thirty-one malignant, two high-risk and eight benign mass-like lesions were analysed. Intra-reader agreement was almost perfect (ICC-R1 = 0.974; ICC-R2 = 0.990) while inter-reader agreement was substantial (ICC from 0.615 to 0.682). Bland-Altman plots revealed a significant bias in ADC values measured between O-SW and S-WS (P = 0.025), no further systematic differences were identified. CV varied from 6.8 % to 7.9 %. Post-processing systems may have a significant, although minor, impact on ADC measurements in breast lesions. While intra-reader agreement is high, the main source of ADC variability seems to be caused by inter-reader variation. • ADC provides quantitative information on breast lesions independent from the system used. • ADC measurement using different workstations and software systems is generally reliable. • Systematic, but minor, differences may occur between different post-processing systems. • Inter-reader agreement of ADC measurements exceeded intra-reader agreement.
The Application of Six Sigma Techniques in the Evaluation of Enzyme Measurement Procedures in China.
Zhang, Chuanbao; Zhao, Haijian; Wang, Jing; Zeng, Jie; Wang, Zhiguo
2015-01-01
Recently, Six Sigma techniques have been adopted by clinical laboratories to evaluate laboratory performance. Measurement procedures in laboratories can be categorized as "excellent", "good", and "improvement needed" based on sigma (σ) metrics of σ ≥ 6, 3 ≤ σ < 6, and σ < 3, respectively. The quality goal index (QGI) was further investigated for measurement procedures with σ ≤ 3. Improvements of the procedures were recommended based on QGI: QGI < 0.8 indicates that the precision of the procedure needs to be improved; QGI > 1.2 indicates that the trueness of the procedure needs to be improved; 0.8 ≤ QGI ≤ 1.2 indicates that both the precision and trueness of the procedure need to be improved. Fresh frozen sera containing seven enzymes (ALT, ALP, AMY, AST, CK, GGT, and LDH) were sent to 78 clinical laboratories in China. The biases for measurement procedures in each laboratory (Bias) were calculated based on the target values assigned by 18 laboratories performing IFCC (International Federation of Clinical Chemistry and Laboratory medicine) recommended reference methods. The imprecision of each measurement procedure was represented by coefficient variations (CV) calculated based on internal quality control (IQC) data. The σ and QGI values were calculated as follows: σ = (TEa-Bias)/CV; QGI = Bias/(1.5 x CV). TEa is allowable total error for each enzyme derived from biological variation. Our study indicated that 7.9% (6/76, ALP) to 31.0% (18/58, AMY) of the participating laboratories were scored as "excellent" (σ ≥ 6), 21.1% (16/76, ALP) to 41.3% (31/75, CK) of the laboratories were scored as "good" (3 ≤ σ < 6), and 31.0% (18/58, AMY) to 71.1% (54/76, ALP) of the laboratories need to improve their enzyme measurement procedures (σ < 3). For those with σ < 3, QGIs were further calculated. Based on QGI values, 8.6% (5/58, AMY) to 35.9% (28/78, LDH) of the laboratories (QGI < 0.8) need to improve the precision of the procedures, 8.0% (6/75, CK) to 52.6% (40/76, ALP) of the laboratories (QGI ≤ 1.2) need to improve the trueness of the procedures; and 2.7% (2/75, AST) to 16.3% (8/49, GGT) of the laboratories (0.8 ≤ QGI ≤ 1.2) need to improve both the precision and trueness of the procedures. Even though rapid progress has been made to standardize serum enzyme measurements in China in recent years, our study using Six Sigma techniques still suggested that approximately 31.1% to 71.0% of the laboratories need to improve their enzyme measurement procedures, either in terms of precision, trueness, or both.
O'Neal, Wanda K; Anderson, Wayne; Basta, Patricia V; Carretta, Elizabeth E; Doerschuk, Claire M; Barr, R Graham; Bleecker, Eugene R; Christenson, Stephanie A; Curtis, Jeffrey L; Han, Meilan K; Hansel, Nadia N; Kanner, Richard E; Kleerup, Eric C; Martinez, Fernando J; Miller, Bruce E; Peters, Stephen P; Rennard, Stephen I; Scholand, Mary Beth; Tal-Singer, Ruth; Woodruff, Prescott G; Couper, David J; Davis, Sonia M
2014-01-08
As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100). 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers.
2014-01-01
Background As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100™). Methods 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. Results 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. Conclusions There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers. PMID:24397870
Nakazato, Yuichi; Kurane, Riichi; Hirose, Satoru; Watanabe, Akihisa; Shimoyama, Hiromi
2017-01-01
Several epidemiological studies have demonstrated associations between variability in a number of biological parameters and adverse outcomes. As the variability may reflect impaired homeostatic regulation, we assessed albumin variability over time in chronic hemodialysis (HD) patients. Data from 1346 subjects who received chronic HD treatment from May 2001 to February 2015 were analyzed according to three phases of HD treatment: post-HD initiation, during maintenance HD treatment, and before death. The serum albumin values were grouped according to the time interval from HD initiation or death, and the yearly trends for both the albumin levels and the intra-individual albumin variability (quantified by the residual coefficient of variation: Alb-rCV) were examined. The HD initiation and death-associated changes were also analyzed using generalized additive mixed models. Furthermore, the long-term trend throughout the maintenance treatment period was evaluated separately using linear regression models. Albumin levels and variability showed distinctive changes during each of the 3 periods. After HD initiation, albumin variability decreased and reached a nadir within a year. During the subsequent maintenance treatment period (interquartile range = 5.2-11.0 years), the log Alb-rCV showed a significant upward trend (mean slope: 0.011 ± 0.035 /year), and its overall mean was -1.49 ± 0.08 (equivalent to an Alb-rCV of 3.22%). During the 1-2 years before death, this upward trend clearly accelerated, and the mean log Alb-rCV in the last year of life was -1.36 ± 0.17. The albumin levels and variability were negatively correlated with each other and exhibited exactly opposite movements throughout the course of chronic HD treatment. Different from the albumin levels, albumin variability was not dependent on chronological age but was independently associated with an individual's aging and death process. The observed upward trend in albumin variability seems to be consistent with a presumed aging-related decline in homeostatic capacity.
Population Pharmacokinetics of Atazanavir in Patients with Human Immunodeficiency Virus Infection▿
Colombo, Sara ; Buclin, Thierry; Cavassini, Matthias; Décosterd, Laurent A.; Telenti, Amalio; Biollaz, Jérôme; Csajka, Chantal
2006-01-01
Atazanavir (ATV) is a new azapeptide protease inhibitor recently approved and currently used at a fixed dose of either 300 mg once per day (q.d.) in combination with 100 mg ritonavir (RTV) or 400 mg q.d. without boosting. ATV is highly bound to plasma proteins and extensively metabolized by CYP3A4. Since ATV plasma levels are highly variable and seem to be correlated with both viral response and toxicity, dosage individualization based on plasma concentration monitoring might be indicated. This study aimed to assess the ATV pharmacokinetic profile in a target population of HIV patients, to characterize interpatient and intrapatient variability, and to identify covariates that might influence ATV disposition. A population analysis was performed with NONMEM with 574 plasma samples from a cohort of 214 randomly selected patients receiving ATV. A total of 346 randomly collected ATV plasma levels and 19 full concentration-time profiles at steady state were available. The pharmacokinetic parameter estimates were an oral clearance (CL) of 12.9 liters/h (coefficient of variation [CV], 26%), a volume of distribution of 88.3 liters (CV, 29%), an absorption rate constant of 0.405 h−1 (CV, 122%), and a lag time of 0.88 h. A relative bioavailability value was introduced to account for undercompliance due to infrequent follow-ups (0.81; CV, 45%). Among the covariates tested, only RTV significantly reduced CL by 46%, thereby increasing the ATV elimination half-life from 4.6 h to 8.8 h. The pharmacokinetic parameters of ATV were adequately described by a one-compartment population model. The concomitant use of RTV improved the pharmacokinetic profile. However, the remaining high interpatient variability suggests the possibility of an impact of unmeasured covariates, such as genetic traits or environmental influences. This population pharmacokinetic model, together with therapeutic drug monitoring and Bayesian dosage adaptation, can be helpful in the selection and adaptation of ATV doses. PMID:16940065
Ogata, Fumihiko; Tanaka, Yuko; Kawasaki, Naohito
2014-01-01
In this study, waste edible oil was prepared by both heat and aeration treatment, and the increasing inhibitive effect of tocopherol treatment on the acid value (AV) and carbonyl value (CV) of the oil was investigated. The AV and CV of waste edible oil treated with tocopherol were 0.1-1.0% lower than those of the nontreated oil, indicating that tocopherol exerted a radical-scavenging activity. The concentration of tocopherol decreased with time, while that of the remaining 1,1-diphenyl-2-picrylhydrazyl (DPPH) radicals increased. These results suggest that the addition of tocopherol proved to be useful for preventing the deterioration of waste edible oil.
Azzam, Sausan; Broadwater, Laurie; Li, Shuo; Freeman, Ernest J; McDonough, Jennifer; Gregory, Roger B
2013-05-01
Experimental autoimmune encephalomyelitis (EAE) is an autoimmune, inflammatory disease of the central nervous system that is widely used as a model of multiple sclerosis (MS). Mitochondrial dysfunction appears to play a role in the development of neuropathology in MS and may also play a role in disease pathology in EAE. Here, surface enhanced laser desorption ionization mass spectrometry (SELDI-MS) has been employed to obtain protein expression profiles from mitochondrially enriched fractions derived from EAE and control mouse brain. To gain insight into experimental variation, the reproducibility of sub-cellular fractionation, anion exchange fractionation as well as spot-to-spot and chip-to-chip variation using pooled samples from brain tissue was examined. Variability of SELDI mass spectral peak intensities indicates a coefficient of variation (CV) of 15.6% and 17.6% between spots on a given chip and between different chips, respectively. Thinly slicing tissue prior to homogenization with a rotor homogenizer showed better reproducibility (CV = 17.0%) than homogenization of blocks of brain tissue with a Teflon® pestle (CV = 27.0%). Fractionation of proteins with anion exchange beads prior to SELDI-MS analysis gave overall CV values from 16.1% to 18.6%. SELDI mass spectra of mitochondrial fractions obtained from brain tissue from EAE mice and controls displayed 39 differentially expressed proteins (p≤ 0.05) out of a total of 241 protein peaks observed in anion exchange fractions. Hierarchical clustering analysis showed that protein fractions from EAE animals with severe disability clearly segregated from controls. Several components of electron transport chain complexes (cytochrome c oxidase subunit 6b1, subunit 6C, and subunit 4; NADH dehydrogenase flavoprotein 3, alpha subcomplex subunit 2, Fe-S protein 4, and Fe-S protein 6; and ATP synthase subunit e) were identified as possible differentially expressed proteins. Myelin Basic Protein isoform 8 (MBP8) (14.2 kDa) levels were lower in EAE samples with advanced disease relative to controls, while an MBP fragment (12. 4kDa), likely due to calpain digestion, was increased in EAE relative to controls. The appearance of MBP in mitochondrially enriched fractions is due to tissue freezing and storage, as MBP was not found associated with mitochondria obtained from fresh tissue. SELDI mass spectrometry can be employed to explore the proteome of a complex tissue (brain) and obtain protein profiles of differentially expressed proteins from protein fractions. Appropriate homogenization protocols and protein fractionation using anion exchange beads can be employed to reduce sample complexity without introducing significant additional variation into the SELDI mass spectra beyond that inherent in the SELDI- MS method itself. SELDI-MS coupled with principal component analysis and hierarchical cluster analysis provides protein patterns that can clearly distinguish the disease state from controls. However, identification of individual differentially expressed proteins requires a separate purification of the proteins of interest by polyacrylamide electrophoresis prior to trypsin digestion and peptide mass fingerprint analysis, and unambiguous identification of differentially expressed proteins can be difficult if protein bands consist of several proteins with similar molecular weights.
2013-01-01
Background Experimental autoimmune encephalomyelitis (EAE) is an autoimmune, inflammatory disease of the central nervous system that is widely used as a model of multiple sclerosis (MS). Mitochondrial dysfunction appears to play a role in the development of neuropathology in MS and may also play a role in disease pathology in EAE. Here, surface enhanced laser desorption ionization mass spectrometry (SELDI-MS) has been employed to obtain protein expression profiles from mitochondrially enriched fractions derived from EAE and control mouse brain. To gain insight into experimental variation, the reproducibility of sub-cellular fractionation, anion exchange fractionation as well as spot-to-spot and chip-to-chip variation using pooled samples from brain tissue was examined. Results Variability of SELDI mass spectral peak intensities indicates a coefficient of variation (CV) of 15.6% and 17.6% between spots on a given chip and between different chips, respectively. Thinly slicing tissue prior to homogenization with a rotor homogenizer showed better reproducibility (CV = 17.0%) than homogenization of blocks of brain tissue with a Teflon® pestle (CV = 27.0%). Fractionation of proteins with anion exchange beads prior to SELDI-MS analysis gave overall CV values from 16.1% to 18.6%. SELDI mass spectra of mitochondrial fractions obtained from brain tissue from EAE mice and controls displayed 39 differentially expressed proteins (p≤ 0.05) out of a total of 241 protein peaks observed in anion exchange fractions. Hierarchical clustering analysis showed that protein fractions from EAE animals with severe disability clearly segregated from controls. Several components of electron transport chain complexes (cytochrome c oxidase subunit 6b1, subunit 6C, and subunit 4; NADH dehydrogenase flavoprotein 3, alpha subcomplex subunit 2, Fe-S protein 4, and Fe-S protein 6; and ATP synthase subunit e) were identified as possible differentially expressed proteins. Myelin Basic Protein isoform 8 (MBP8) (14.2 kDa) levels were lower in EAE samples with advanced disease relative to controls, while an MBP fragment (12. 4kDa), likely due to calpain digestion, was increased in EAE relative to controls. The appearance of MBP in mitochondrially enriched fractions is due to tissue freezing and storage, as MBP was not found associated with mitochondria obtained from fresh tissue. Conclusions SELDI mass spectrometry can be employed to explore the proteome of a complex tissue (brain) and obtain protein profiles of differentially expressed proteins from protein fractions. Appropriate homogenization protocols and protein fractionation using anion exchange beads can be employed to reduce sample complexity without introducing significant additional variation into the SELDI mass spectra beyond that inherent in the SELDI- MS method itself. SELDI-MS coupled with principal component analysis and hierarchical cluster analysis provides protein patterns that can clearly distinguish the disease state from controls. However, identification of individual differentially expressed proteins requires a separate purification of the proteins of interest by polyacrylamide electrophoresis prior to trypsin digestion and peptide mass fingerprint analysis, and unambiguous identification of differentially expressed proteins can be difficult if protein bands consist of several proteins with similar molecular weights. PMID:23635033
Rozen, Guy; Vaid, Jeena; Hosseini, Seyed Mohammadreza; Kaadan, M Ihsan; Rafael, Allon; Roka, Attila; Poh, Yukkee C; Poh, Ming-Zher; Heist, Edwin Kevin; Ruskin, Jeremy Neil
2018-05-15
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in adults, associated with significant morbidity, increased mortality, and rising health-care costs. Simple and available tools for the accurate detection of arrhythmia recurrence in patients after electrical cardioversion (CV) or ablation procedures for AF can help to guide therapeutic decisions. We conducted a prospective, single-center study to evaluate the accuracy of Cardiio Rhythm Mobile Application (CRMA) for AF detection. Patients >18 years of age who were scheduled for elective CV for AF were enrolled in the study. CRMA finger pulse recordings, utilizing an iPhone camera, were obtained before (pre-CV) and after (post-CV) the CV. The findings were validated against surface electrocardiograms. Ninety-eight patients (75.5% men), mean age of 67.7 ± 10.5 years, were enrolled. No electrocardiogram for validation was available in 1 case. Pre-CV CRMA readings were analyzed in 97 of the 98 patients. Post-CV CRMA readings were analyzed for 92 of 93 patients who underwent CV. One patient left before the recording was obtained. The Cardiio Rhythm Mobile Application correctly identified 94 of 101 AF recordings (93.1%) as AF and 80 of 88 non-AF recordings (90.1%) as non-AF. The sensitivity was 93.1% (95% confidence interval [CI] = 86.9% to 97.2%) and the specificity was 90.9% (95% CI = 82.9% to 96.0%). The positive predictive value was 92.2% (95% CI = 85.8% to 95.8%) and the negative predictive value was 92.0% (95% CI = 94.8% to 95.9%). In conclusion, the CRMA demonstrates promising potential in accurate detection and discrimination of AF from normal sinus rhythm in patients with a history of AF. Copyright © 2018 Elsevier Inc. All rights reserved.
Chiu, Hsien-Tsai; Li, Tsai-Chung; Li, Chia-Ing; Liu, Chiu-Shong; Lin, Wen-Yuan; Lin, Cheng-Chieh
2017-01-01
This study aims to examine the association between visit-to-visit glucose variability, which was measured by coefficient of variation (CV) of fasting plasma glucose (FPG) and hemoglobin A1c (HbA1c), and risk of chronic obstructive pulmonary disease (COPD) in a large number of patients with type 2 diabetes with an average follow-up of 7.58 years. We conducted a retrospective cohort study on 27,257 patients with type 2 diabetes who participated in the National Diabetes Case Management Program in Taiwan. Visit-to-visit variability in HbA1c and FPG at baseline and the incidence of COPD were analyzed using a modified Cox proportional hazards model considering competing risks. A total of 2,346 incident cases of COPD. Patients were grouped into tertiles of FPG-CV and HbA1c-CV. The incidence rates in the first, second, and third tertiles were 9.87, 11.06, and 13.19, respectively, for FPG-CV and 10.2, 11.81, and 12.07, for HbA1c-CV per 1000 person-years. After adjusting for age, gender, diabetes duration, treatment type, smoking, hypertension, hyperlipidemia, baseline FPG and HbA1c levels, and complications, both FPG-CV and HbA1c-CV were independently associated with COPD. The hazard ratios of COPD for the third terile compared with the first tertile of FPG-CV were 1.26 (95% confidence interval [CI]: 1.13-1.40). Moreover, the hazard ratios of COPD for the third and second tertiles compared with the first tertile of HbA1c-CV were 1.13 (1.02-1.25) and 1.13 (1.02-1.26), respectively. Patients with FPG-CV higher than 34.6% or HbA1c-CV higher than 8.4% exhibited an increased risk of COPD. This finding confirmed the linear relationship of FPG-CV and HbA1c-CV to COPD. Visit-to-visit variability in FPG and HbA1c levels are strong predictors of COPD in patients with type 2 diabetes. Future studies should focus on lung dysfunction in diabetes, and adequate glucose control strategy in regular clinical practices must be established for COPD prevention.
Chaplais, Elodie; Greene, David; Hood, Anita; Telfer, Scott; du Toit, Verona; Singh-Grewal, Davinder; Burns, Joshua; Rome, Keith; Schiferl, Daniel J; Hendry, Gordon J
2014-07-19
Peripheral quantitative computed tomography (pQCT) is an established technology that allows for the measurement of the material properties of bone. Alterations to bone architecture are associated with an increased risk of fracture. Further pQCT research is necessary to identify regions of interest that are prone to fracture risk in people with chronic diseases. The second metatarsal is a common site for the development of insufficiency fractures, and as such the aim of this study was to assess the reproducibility of a novel scanning protocol of the second metatarsal using pQCT. Eleven embalmed cadaveric leg specimens were scanned six times; three times with and without repositioning. Each foot was positioned on a custom-designed acrylic foot plate to permit unimpeded scans of the region of interest. Sixty-six scans were obtained at 15% (distal) and 50% (mid shaft) of the second metatarsal. Voxel size and scan speed were reduced to 0.40 mm and 25 mm.sec(-1). The reference line was positioned at the most distal portion of the 2(nd) metatarsal. Repeated measurements of six key variables related to bone properties were subject to reproducibility testing. Data were log transformed and reproducibility of scans were assessed using intraclass correlation coefficients (ICC) and coefficients of variation (CV%). Reproducibility of the measurements without repositioning were estimated as: trabecular area (ICC 0.95; CV% 2.4), trabecular density (ICC 0.98; CV% 3.0), Strength Strain Index (SSI) - distal (ICC 0.99; CV% 5.6), cortical area (ICC 1.0; CV% 1.5), cortical density (ICC 0.99; CV% 0.1), SSI - mid shaft (ICC 1.0; CV% 2.4). Reproducibility of the measurements after repositioning were estimated as: trabecular area (ICC 0.96; CV% 2.4), trabecular density (ICC 0.98; CV% 2.8), SSI - distal (ICC 1.0; CV% 3.5), cortical area (ICC 0.99; CV%2.4), cortical density (ICC 0.98; CV% 0.8), SSI - mid shaft (ICC 0.99; CV% 3.2). The scanning protocol generated excellent reproducibility for key bone properties measured at the distal and mid-shaft regions of the 2(nd) metatarsal. This protocol extends the capabilities of pQCT to evaluate bone quality in people who may be at an increased risk of metatarsal insufficiency fractures.
2014-01-01
Background Peripheral quantitative computed tomography (pQCT) is an established technology that allows for the measurement of the material properties of bone. Alterations to bone architecture are associated with an increased risk of fracture. Further pQCT research is necessary to identify regions of interest that are prone to fracture risk in people with chronic diseases. The second metatarsal is a common site for the development of insufficiency fractures, and as such the aim of this study was to assess the reproducibility of a novel scanning protocol of the second metatarsal using pQCT. Methods Eleven embalmed cadaveric leg specimens were scanned six times; three times with and without repositioning. Each foot was positioned on a custom-designed acrylic foot plate to permit unimpeded scans of the region of interest. Sixty-six scans were obtained at 15% (distal) and 50% (mid shaft) of the second metatarsal. Voxel size and scan speed were reduced to 0.40 mm and 25 mm.sec-1. The reference line was positioned at the most distal portion of the 2nd metatarsal. Repeated measurements of six key variables related to bone properties were subject to reproducibility testing. Data were log transformed and reproducibility of scans were assessed using intraclass correlation coefficients (ICC) and coefficients of variation (CV%). Results Reproducibility of the measurements without repositioning were estimated as: trabecular area (ICC 0.95; CV% 2.4), trabecular density (ICC 0.98; CV% 3.0), Strength Strain Index (SSI) - distal (ICC 0.99; CV% 5.6), cortical area (ICC 1.0; CV% 1.5), cortical density (ICC 0.99; CV% 0.1), SSI – mid shaft (ICC 1.0; CV% 2.4). Reproducibility of the measurements after repositioning were estimated as: trabecular area (ICC 0.96; CV% 2.4), trabecular density (ICC 0.98; CV% 2.8), SSI - distal (ICC 1.0; CV% 3.5), cortical area (ICC 0.99; CV%2.4), cortical density (ICC 0.98; CV% 0.8), SSI – mid shaft (ICC 0.99; CV% 3.2). Conclusions The scanning protocol generated excellent reproducibility for key bone properties measured at the distal and mid-shaft regions of the 2nd metatarsal. This protocol extends the capabilities of pQCT to evaluate bone quality in people who may be at an increased risk of metatarsal insufficiency fractures. PMID:25037451
Tomimatsu, Hajime; Tang, Yanhong
2012-08-01
To understand dynamic photosynthetic characteristics in response to fluctuating light under a high CO(2) environment, we examined photosynthetic induction in two poplar genotypes from two species, Populus koreana 9 trichocarpa cv. Peace and Populus euramericana cv. I-55, respectively. Stomata of cv. Peace barely respond to changes in photosynthetic photon flux density (PFD), whereas those of cv. I-55 show a normal response to variations in PFD at ambient CO(2). The plants were grown under three CO2 regimes (380, 700, and 1,020 μmol CO(2) mol(-1) in air) for approximately 2 months. CO2 gas exchange was measured in situ in the three CO2 regimes under a sudden PFD increase from 20 to 800 μmol m(-2) s(-1). In both genotypes, plants grown under higher CO(2) conditions had a higher photosynthetic induction state, shorter induction time, and reduced induction limitation to photosynthetic carbon gain. Plants of cv. I-55 showed a much larger increase in induction state and decrease in induction time under high CO(2) regimes than did plants of cv. Peace. These showed that, throughout the whole induction process, genotype cv. I-55 had a much smaller reduction of leaf carbon gain under the two high CO(2) regimes than under the ambient CO(2) regime, while the high CO(2) effect was smaller in genotype cv. Peace. The results suggest that a high CO(2) environment can reduce both biochemical and stomatal limitations of leaf carbon gain during the photosynthetic induction process, and that a rapid stomatal response can further enhance the high CO(2) effect.
Pothuaud, L; Benhamou, C L; Porion, P; Lespessailles, E; Harba, R; Levitz, P
2000-04-01
The purpose of this work was to understand how fractal dimension of two-dimensional (2D) trabecular bone projection images could be related to three-dimensional (3D) trabecular bone properties such as porosity or connectivity. Two alteration processes were applied to trabecular bone images obtained by magnetic resonance imaging: a trabeculae dilation process and a trabeculae removal process. The trabeculae dilation process was applied from the 3D skeleton graph to the 3D initial structure with constant connectivity. The trabeculae removal process was applied from the initial structure to an altered structure having 99% of porosity, in which both porosity and connectivity were modified during this second process. Gray-level projection images of each of the altered structures were simply obtained by summation of voxels, and fractal dimension (Df) was calculated. Porosity (phi) and connectivity per unit volume (Cv) were calculated from the 3D structure. Significant relationships were found between Df, phi, and Cv. Df values increased when porosity increased (dilation and removal processes) and when connectivity decreased (only removal process). These variations were in accordance with all previous clinical studies, suggesting that fractal evaluation of trabecular bone projection has real meaning in terms of porosity and connectivity of the 3D architecture. Furthermore, there was a statistically significant linear dependence between Df and Cv when phi remained constant. Porosity is directly related to bone mineral density and fractal dimension can be easily evaluated in clinical routine. These two parameters could be associated to evaluate the connectivity of the structure.
Little, B H; Robson, R; Roemer, B; Scott, C S
2005-02-01
This study evaluated the extended use of a haematology analyser (Abbott Cell-Dyn CD4000) for the immunofluorescent enumeration of foeto-maternal haemorrhage (FMH) with fluorescein isothiocyanate-labelled monoclonal anti-RhD. Method performance was assessed with artificial FMH standards, and a series of 44 clinical samples. Within run precision was <15% (coefficient of variation, CV) for FMH volumes of 3 ml and above, 18.8% at an FMH volume of 2 ml and 31.7% at an FMH volume of 1 ml. Linearity analysis showed excellent agreement (observed FMH% = 0.98x expected FMH% + 0.02), and a close relationship (R(2) = 0.99) between observed and expected FMH percentages. The lower limit of quantification of the CD4000 (SRP-Ret) method with a maximum CV of 15% was 1.6 ml, and the limit of detection was <1 ml. Parallel Kleihauer-Betke test (KBT) assessments of FMH standards showed an overall trend for higher KBT values (observed = 1.25x expected - 0.38). At an FMH level of 4 ml, KBT observer estimates ranged from 0.57 to 11.94 ml with a mean inter-observer CV of 63%. For 44 clinical samples, there was decision point agreement between KBT and SRP-Ret results for 42 samples with an FMH of <2 ml. Analysis in the low FMH range (<1 ml) showed that small volume foetal leaks could be detected with the SRP-Ret method in most of 23 samples with negative KBT results. CD4000 SRP-Ret method performance for FMH determination was similar to that reported for flow cytometry.
Enterovirus Migration Patterns between France and Tunisia
Othman, Ines; Mirand, Audrey; Slama, Ichrak; Mastouri, Maha; Peigue-Lafeuille, Hélène; Aouni, Mahjoub; Bailly, Jean-Luc
2015-01-01
The enterovirus (EV) types echovirus (E-) 5, E-9, and E-18, and coxsackievirus (CV-) A9 are infrequently reported in human diseases and their epidemiologic features are poorly defined. Virus transmission patterns between countries have been estimated with phylogenetic data derived from the 1D/VP1 and 3CD gene sequences of a sample of 74 strains obtained in France (2000–2012) and Tunisia (2011–2013) and from the publicly available sequences. The EV types (E-5, E-9, and E-18) exhibited a lower worldwide genetic diversity (respective number of genogroups: 4, 5, and 3) in comparison to CV-A9 (n = 10). The phylogenetic trees estimated with both 1D/VP1 and 3CD sequence data showed variations in the number of co-circulating lineages over the last 20 years among the four EV types. Despite the low number of genogroups in E-18, the virus exhibited the highest number of recombinant 3CD lineages (n = 10) versus 4 (E-5) to 8 (E-9). The phylogenies provided evidence of multiple transportation events between France and Tunisia involving E-5, E-9, E-18, and CV-A9 strains. Virus spread events between France and 17 other countries in five continents had high probabilities of occurrence as those between Tunisia and two European countries other than France. All transportation events were supported by BF values > 10. Inferring the source of virus transmission from phylogenetic data may provide insights into the patterns of sporadic and epidemic diseases caused by EVs. PMID:26709514
Meier, Daniel T; Entrup, Leon; Templin, Andrew T; Hogan, Meghan F; Samarasekera, Thanya; Zraika, Sakeneh; Boyko, Edward J; Kahn, Steven E
2015-08-01
Culture of isolated rodent islets is widely used in diabetes research to assess different endpoints, including outcomes requiring histochemical staining. As islet yields during isolation are limited, we determined the number of islets required to obtain reliable data by histology. We found that mean values for insulin-positive β-cell area/islet area, thioflavin S-positive amyloid area/islet area and β-cell apoptosis do not vary markedly when more than 30 islets are examined. Measurement variability declines as more islets are quantified, so that the variability of the coefficient of variation (CV) in human islet amyloid polypeptide (hIAPP) transgenic islets for β-cell area/islet area, amyloid area/islet area and β-cell apoptosis are 13.20% ± 1.52%, 10.03% ± 1.76% and 6.78% ± 1.53%, respectively (non-transgenic: 7.65% ± 1.17% β-cell area/islet area and 8.93% ± 1.56% β-cell apoptosis). Increasing the number of islets beyond 30 had marginal effects on the CV. Using 30 islets, 6 hIAPP-transgenic preparations are required to detect treatment effects of 14% for β-cell area/islet area, 30% for amyloid area/islet area and 23% for β-cell apoptosis (non-transgenic: 9% for β-cell area/islet area and 45% for β-cell apoptosis). This information will be of value in the design of studies using isolated islets to examine β cells and islet amyloid. © The Author(s) 2015.
Hong, Samin; Kim, Chan Yun; Lee, Won Seok; Seong, Gong Je
2010-01-01
To assess the reproducibility of the new spectral domain Cirrus high-definition optical coherence tomography (HD-OCT; Carl Zeiss Meditec, Dublin, CA, USA) for analysis of peripapillary retinal nerve fiber layer (RNFL) thickness in healthy eyes. Thirty healthy Korean volunteers were enrolled. Three optic disc cube 200 x 200 Cirrus HD-OCT scans were taken on the same day in discontinuous sessions by the same operator without using the repeat scan function. The reproducibility of the calculated RNFL thickness and probability code were determined by the intraclass correlation coefficient (ICC), coefficient of variation (CV), test-retest variability, and Fleiss' generalized kappa (kappa). Thirty-six eyes were analyzed. For average RNFL thickness, the ICC was 0.970, CV was 2.38%, and test-retest variability was 4.5 microm. For all quadrants except the nasal, ICCs were 0.972 or higher and CVs were 4.26% or less. Overall test-retest variability ranged from 5.8 to 8.1 microm. The kappa value of probability codes for average RNFL thickness was 0.690. The kappa values of quadrants and clock-hour sectors were lower in the nasal areas than in other areas. The reproducibility of Cirrus HD-OCT to analyze peripapillary RNFL thickness in healthy eyes was excellent compared with the previous reports for time domain Stratus OCT. For the calculated RNFL thickness and probability code, variability was relatively higher in the nasal area, and more careful analyses are needed.
Ćwiklińska, Agnieszka; Dąbrowska, Hanna; Kowalski, Robert; Kuchta, Agnieszka; Kortas-Stempak, Barbara; Fijałkowska, Aleksandra; Bednarczuk, Gabriela; Jankowski, Maciej
2018-05-11
The ratio of albumin to creatinine (ACR) is an important parameter used for detection of albuminuria in patients with early kidney damage. The aim of the study was to evaluate the harmonization of ACR results among Polish participants in an international external quality assessment (EQA) program, and to evaluate the impact of albumin and creatinine analytical performance on the harmonization of ACR results. We analyzed 182 results of albumin, 202 of creatinine, and 180 of ACR obtained from Polish laboratories in an EQA program organized by Labquality. The dispersion of the results in surveys and percentage differences between the results and target values were calculated. Moreover, differences between method groups were assessed. The inter-laboratory coefficient of variation (CV) for ACR was 36%. Only 74% of results of Polish laboratories were within the target limits; for 11% of the results, an incorrect albuminuria category would have been reported. The inter-laboratory CV for albumin was 20%, 2.6-fold higher than for creatinine. Significant differences between method groups for albumin determination have been observed, even when the same measurement technique was used. The greatest difference between two groups was 23%, 2.5-fold greater in comparison to creatinine. There is an insufficient harmonization of ACR values among Polish laboratories, caused mainly by urine albumin analytical performance. Given the important role of ACR in the classification, monitoring and treatment of kidney damage, the harmonization of albumin measurements is crucial and urgently needed.
Effect of particle size on mixing degree in dispensation.
Nakamura, Hitoshi; Yanagihara, Yoshitsugu; Sekiguchi, Hiroko; Ohtani, Michiteru; Kariya, Satoru; Uchino, Katsuyoshi; Suzuki, Hiroshi; Iga, Tatsuji
2004-03-01
By using lactose colored with erythrocin, we examined the effect of particle size on mixing degree during the preparation of triturations with a mortar and pestle. We used powders with different distributions of particle sizes, i.e., powder that passed through 32-mesh but was trapped on a 42-mesh sieve (32/42-mesh powder), powder that passed through a 42-mesh sieve but was trapped on a 60-mesh sieve (42/60-mesh powder), powder that passed through a 60-mesh sieve but was trapped on a 100-mesh sieve (60/100-mesh powder), and powder that passes through a 100-mesh sieve (> 100-mesh powder). The mixing degree of colored powder and non-colored powder whose distribution of particle sizes was the same as that of the colored powder was excellent. The coefficient of variation (CV) value of the mixing degree was 6.08% after 40 rotations when colored powder was mixed with non-colored powder that both passed through a 100-mesh sieve. The CV value of the mixing degree was low in the case of mixing of colored and non-colored powders with different particle size distributions. After mixing, about 50% of 42/60-mesh powder had become smaller particles, whereas the distribution of particle sizes was not influenced by the mixing of 60/100-mesh powder. It was suggested that the mixing degree is affected by distribution of particle sizes. It may be important to determine the mixing degrees for drugs with narrow therapeutic ranges.
Kelsey, Katharine C.; Wickland, Kimberly P.; Striegl, Robert G.; Neff, Jason C.
2012-01-01
Carbon dynamics of high-latitude regions are an important and highly uncertain component of global carbon budgets, and efforts to constrain estimates of soil-atmosphere carbon exchange in these regions are contingent on accurate representations of spatial and temporal variability in carbon fluxes. This study explores spatial and temporal variability in soilatmosphere carbon dynamics at both fine and coarse spatial scales in a high-elevation, permafrost-dominated boreal black spruce forest. We evaluate the importance of landscape-level investigations of soil-atmosphere carbon dynamics by characterizing seasonal trends in soil-atmosphere carbon exchange, describing soil temperature-moisture-respiration relations, and quantifying temporal and spatial variability at two spatial scales: the plot scale (0–5 m) and the landscape scale (500–1000 m). Plot-scale spatial variability (average variation on a given measurement day) in soil CO2 efflux ranged from a coefficient of variation (CV) of 0.25 to 0.69, and plot-scale temporal variability (average variation of plots across measurement days) in efflux ranged from a CV of 0.19 to 0.36. Landscape-scale spatial and temporal variability in efflux was represented by a CV of 0.40 and 0.31, respectively, indicating that plot-scale spatial variability in soil respiration is as great as landscape-scale spatial variability at this site. While soil respiration was related to soil temperature at both the plot- and landscape scale, landscape-level descriptions of soil moisture were necessary to define soil respiration-moisture relations. Soil moisture variability was also integral to explaining temporal variability in soil respiration. Our results have important implications for research efforts in high-latitude regions where remote study sites make landscape-scale field campaigns challenging.
Reinstein, Dan Z.; Archer, Timothy J.; Silverman, Ronald H.; Coleman, D. Jackson
2008-01-01
Purpose To determine the accuracy, repeatability, and reproducibility of measurement of lateral dimensions using the Artemis (Ultralink LLC) very high-frequency (VHF) digital ultrasound (US) arc scanner. Setting London Vision Clinic, London, United Kingdom. Methods A test object was measured first with a micrometer and then with the Artemis arc scanner. Five sets of 10 consecutive B-scans of the test object were performed with the scanner. The test object was removed from the system between each scan set. One expert observer and one newly trained observer separately measured the lateral dimension of the test object. Two-factor analysis of variance was performed. The accuracy was calculated as the average bias of the scan set averages. The repeatability and reproducibility coefficients were calculated. The coefficient of variation (CV) was calculated for repeatability and reproducibility. Results The test object was measured to be 10.80 mm wide. The mean lateral dimension bias was 0.00 mm. The repeatability coefficient was 0.114 mm. The reproducibility coefficient was 0.026 mm. The repeatability CV was 0.38%, and the reproducibility CV was 0.09%. There was no statistically significant variation between observers (P = .0965). There was a statistically significant variation between scan sets (P = .0036) attributed to minor vertical changes in the alignment of the test object between consecutive scan sets. Conclusion The Artemis VHF digital US arc scanner obtained accurate, repeatable, and reproducible measurements of lateral dimensions of the size commonly found in the anterior segment. PMID:17081860
Quillet, Edwige; Bégout, Marie-Laure; Aupérin, Benoit; Khaw, Hooi Ling; Millot, Sandie; Valotaire, Claudiane; Kernéis, Thierry; Labbé, Laurent; Prunet, Patrick; Dupont-Nivet, Mathilde
2017-01-01
Adaptive phenotypic plasticity is a key component of the ability of organisms to cope with changing environmental conditions. Fish have been shown to exhibit a substantial level of phenotypic plasticity in response to abiotic and biotic factors. In the present study, we investigate the link between environmental sensitivity assessed globally (revealed by phenotypic variation in body weight) and more targeted physiological and behavioral indicators that are generally used to assess the sensitivity of a fish to environmental stressors. We took advantage of original biological material, the rainbow trout isogenic lines, which allowed the disentangling of the genetic and environmental parts of the phenotypic variance. Ten lines were characterized for the changes of body weight variability (weight measurements taken every month during 18 months), the plasma cortisol response to confinement stress (3 challenges) and a set of selected behavioral indicators. This study unambiguously demonstrated the existence of genetic determinism of environmental sensitivity, with some lines being particularly sensitive to environmental fluctuations and others rather insensitive. Correlations between coefficient of variation (CV) for body weight and behavioral and physiological traits were observed. This confirmed that CV for body weight could be used as an indicator of environmental sensitivity. As the relationship between indicators (CV weight, risk-taking, exploration and cortisol) was shown to be likely depending on the nature and intensity of the stressor, the joint use of several indicators should help to investigate the biological complexity of environmental sensitivity. PMID:29253015
The Contingent Valuation Method in Public Libraries
ERIC Educational Resources Information Center
Chung, Hye-Kyung
2008-01-01
This study aims to present a new model measuring the economic value of public libraries, combining the dissonance minimizing (DM) and information bias minimizing (IBM) format in the contingent valuation (CV) surveys. The possible biases which are tied to the conventional CV surveys are reviewed. An empirical study is presented to compare the model…
Rose, G; Mulder, H A; Thompson, A N; van der Werf, J H J; van Arendonk, J A M
2015-08-01
Breeding programmes for livestock require economic weights for traits that reflect the most profitable animal in a given production system, which affect the response in each trait after selection. The profitability of sheep production systems is affected by changes in pasture growth as well as grain, meat and wool prices between seasons and across years. Annual pasture growth varies between regions within Australia's Mediterranean climate zone from low growth with long periods of drought to high growth with shorter periods of drought. Therefore, the objective of this study was to assess whether breeding objectives need to be adapted for regions, depending on how reliable the pasture growth is across years. We modelled farms with Merino sheep bred for wool and meat in 10 regions in Western Australia. Across these 10 regions, mean annual pasture growth decreased, and the CV of annual pasture growth increased as pasture growth for regions became less reliable. We calculated economic values for nine traits, optimising management across 11 years, including variation for pasture growth and wool, meat and grain prices between and within years from 2002 to 2012. These economic values were used to calculate responses to selection for each trait for the 10 regions. We identified two potential breeding objectives, one for regions with low or high reliability and the other for regions with medium reliability of pasture growth. Breeding objectives for high or low pasture growth reliability had more emphasis on live weight traits and number of lambs weaned. Breeding objectives for medium reliability of pasture growth had more emphasis on decreasing fibre diameter. Relative economic weights for fleece weight did not change across the regions. Regions with low or high pasture reliability had similar breeding objectives and response to selection, because the relationship between the economic values and CV of pasture growth were not linear for live weight traits and the number of lambs weaned. This non-linearity was caused by differences in distribution of pasture growth between regions, particularly during summer and autumn, when ewes were pregnant, with increases in energy requirements affecting the value of lambs weaned. In addition, increasing live weight increased the intake capacity of sheep, which meant that more poor quality pasture could be consumed during summer and autumn, which had more value in regions with low and high pasture reliability. We concluded that breeding values for sheep production systems should be customised depending on the reliability of pasture growth between years.
An evaluation of soil sampling for 137Cs using various field-sampling volumes.
Nyhan, J W; White, G C; Schofield, T G; Trujillo, G
1983-05-01
The sediments from a liquid effluent receiving area at the Los Alamos National Laboratory and soils from an intensive study area in the fallout pathway of Trinity were sampled for 137Cs using 25-, 500-, 2500- and 12,500-cm3 field sampling volumes. A highly replicated sampling program was used to determine mean concentrations and inventories of 137Cs at each site, as well as estimates of spatial, aliquoting, and counting variance components of the radionuclide data. The sampling methods were also analyzed as a function of soil size fractions collected in each field sampling volume and of the total cost of the program for a given variation in the radionuclide survey results. Coefficients of variation (CV) of 137Cs inventory estimates ranged from 0.063 to 0.14 for Mortandad Canyon sediments, whereas CV values for Trinity soils were observed from 0.38 to 0.57. Spatial variance components of 137Cs concentration data were usually found to be larger than either the aliquoting or counting variance estimates and were inversely related to field sampling volume at the Trinity intensive site. Subsequent optimization studies of the sampling schemes demonstrated that each aliquot should be counted once, and that only 2-4 aliquots out of as many as 30 collected need be assayed for 137Cs. The optimization studies showed that as sample costs increased to 45 man-hours of labor per sample, the variance of the mean 137Cs concentration decreased dramatically, but decreased very little with additional labor.
NASA Astrophysics Data System (ADS)
Eltayeb, Asmaa; Vijayaraghavan, Rajani K.; McCoy, Anthony; Venkatanarayanan, Anita; Yaremchenko, Aleksey A.; Surendran, Rajesh; McGlynn, Enda; Daniels, Stephen
2015-04-01
In this study, nanostructured ceria (CeO2) films are deposited on Si(100) and ITO coated glass substrates by pulsed DC magnetron sputtering using a CeO2 target. The influence on the films of using various gas ambients, such as a high purity Ar and a gas mixture of high purity Ar and O2, in the sputtering chamber during deposition are studied. The film compositions are studied using XPS and SIMS. These spectra show a phase transition from cubic CeO2 to hexagonal Ce2O3 due to the sputtering process. This is related to the transformation of Ce4+ to Ce3+ and indicates a chemically reduced state of CeO2 due to the formation of oxygen vacancies. TGA and electrochemical cyclic voltammetry (CV) studies show that films deposited in an Ar atmosphere have a higher oxygen storage capacity (OSC) compared to films deposited in the presence of O2. CV results specifically show a linear variation with scan rate of the anodic peak currents for both films and the double layer capacitance values for films deposited in Ar/O2 mixed and Ar atmosphere are (1.6 ± 0.2) × 10-4 F and (4.3 ± 0.5) × 10-4 F, respectively. Also, TGA data shows that Ar sputtered samples have a tendency to greater oxygen losses upon reduction compared to the films sputtered in an Ar/O2 mixed atmosphere.
Functional MRI of human pancreas using BOLD contrast: Responses following glucose ingestion.
Chen, Bozhu; Chen, Weibo; Chan, Queenie; Zhou, Nan; He, Jian; Zhou, Zhengyang
2017-09-01
To evaluate the response of the pancreas to glucose ingestion in healthy volunteers by blood oxygenation level-dependent (BOLD) magnetic resonance imaging (MRI). This study was approved by the local Ethics Committee, and informed consent was obtained from all subjects. A multiple gradient recalled echo (mGRE) sequence was performed on a 3.0T MR scanner in 12 healthy volunteers before and after glucose or water ingestion. Pancreatic T2* values were calculated from it at each timepoint, and changes following stimulation were analyzed using summary measures. The valley values and times were compared between the glucose and water ingestion by paired samples t-test. The repeatability of the pancreatic T2* measurements was assessed by calculating the intraclass correlation coefficient (ICC) and coefficient of variation (CV). Pancreatic T2* measurements showed good repeatability (all ICC >0.75). CV for the six baseline acquisitions was 2.74 ± 0.97%, indicating a 5.37% measurement error. A transient but significant decrease (-6.88 ± 1.01%, P value, 0.0005-0.0467) in the pancreatic T2* values was observed within 5 minutes after glucose ingestion, rather than water consumption. Compared to water, glucose ingestion induced earlier (valley times: 3.46 ± 3.22 vs. 7.75 ± 4.09 min, P = 0.0006) and remarkable pancreatic T2* decrease (valley values: -15.33 ± 5.90% vs. -6.88 ± 3.11%, P = 0.0006). BOLD MRI enabled noninvasive quantification of pancreatic T2* changes during glucose stimulation. Glucose ingestion resulted in a rapid and significant pancreatic T2* decrease in healthy young volunteers. 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:831-836. © 2017 International Society for Magnetic Resonance in Medicine.
Solomon, Daniel H.; Kremer, Joel; Curtis, Jeffrey R; Hochberg, Marc C.; Reed, George; Tsao, Peter; Farkouh, Michael E.; Setoguchi, Soko; Greenberg, Jeffrey D.
2010-01-01
Background Cardiovascular (CV) disease has a major impact on patients with rheumatoid arthritis (RA), however, the relative contributions of traditional CV risk factors and markers of RA severity are unclear. We examined the relative importance of traditional CV risk factors and RA markers in predicting CV events. Methods A prospective longitudinal cohort study was conducted in the setting of the CORRONA registry in the United States. Baseline data from subjects with RA enrolled in the CORRONA registry were examined to determine predictors of CV outcomes, including myocardial infarction (MI), stroke or transient ischemic attack (TIA). Possible predictors were of two types: traditional CV risk factors and markers of RA severity. The discriminatory value of these variables was assessed by calculating the area under the receiver operating characteristic curve (c-statistic) in logistic regression. We then assessed the incidence rate for CV events among subjects with an increasing number of traditional CV risk factors and/or RA severity markers. Results The cohort consisted of 10,156 patients with RA followed for a median of 22 months. We observed 76 primary CV events during follow-up for a composite event rate of 3.98 (95% CI 3.08 – 4.88) per 1,000 patient-years. The c-statistic improved from 0.57 for models with only CV risk factors to 0.67 for models with CV risk factors plus age and gender. The c-statistic improved further to 0.71 when markers of RA severity were also added. The incidence rate for CV events was 0 (95% CI 0 – 5.98) for persons without any CV risk factors or markers of RA severity, while in the group with two or more CV risk factors and 3 or more markers of RA severity the incidence was 7.47 (95% CI 4.21–10.73) per 1,000 person-years. Conclusions Traditional CV risk factors and markers of RA severity both contribute to models predicting CV events. Increasing numbers of both types of factors are associated with greater risk. PMID:20444756
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karki, K; Hugo, G; Ford, J
2014-06-15
Purpose: Diffusion-weighted MRI (DW-MRI) is increasingly being investigated for radiotherapy planning and response assessment. Selection of a limited number of b-values in DW-MRI is important to keep geometrical variations low and imaging time short. We investigated various b-value sets to determine an optimal set for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADC IVIM) in nonsmall cell lung cancer. Methods: Seven patients had 27 DW-MRI scans before and during radiotherapy in a 1.5T scanner. Respiratory triggering was applied to the echo-planar DW-MRI with TR=4500ms approximately, TE=74ms, pixel size=1.98X1.98mm{sub 2}, slice thickness=4–6mm andmore » 7 axial slices. Diffusion gradients were applied to all three axes producing traceweighted images with eight b-values of 0–1000μs/μm{sup 2}. Monoexponential model ADC values using various b-value sets were compared to ADC IVIM using all b-values. To compare the relative noise in ADC maps, intra-scan coefficient of variation (CV) of active tumor volumes was computed. Results: ADC IVIM, perfusion coefficient and perfusion fraction for tumor volumes were in the range of 880-1622 μm{sup 2}/s, 8119-33834 μm{sup 2}/s and 0.104–0.349, respectively. ADC values using sets of 250, 800 and 1000; 250, 650 and 1000; and 250–1000μs/μm{sup 2} only were not significantly different from ADC IVIM(p>0.05, paired t-test). Error in ADC values for 0–1000, 50–1000, 100–1000, 250–1000, 500–1000, and three b-value sets- 250, 500 and 1000; 250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2} were 15.0, 9.4, 5.6, 1.4, 11.7, 3.7, 2.0 and 0.2% relative to the reference-standard ADC IVIM, respectively. Mean intrascan CV was 20.2, 20.9, 21.9, 24.9, 32.6, 25.8, 25.4 and 24.8%, respectively, whereas that for ADC IVIM was 23.3%. Conclusion: ADC values of two 3 b-value sets (250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2}) approached ADC IVIM, with relative noise comparable to that of ADC IVIM. These sets may be used to obtain perfusion-insensitive ADC values in lung tumors. E. Weiss: Funding through Varian Medical Systems and Philips Oncology Systems, UpToDate royalties. G. Hugo: NIH R01CA166119, P01 CA116602, NHMRC Project Grant.« less
ERIC Educational Resources Information Center
Weber, Elke U.; Shafir, Sharoni; Blais, Ann-Renee
2004-01-01
This article examines the statistical determinants of risk preference. In a meta-analysis of animal risk preference (foraging birds and insects), the coefficient of variation (CV), a measure of risk per unit of return, predicts choices far better than outcome variance, the risk measure of normative models. In a meta-analysis of human risk…
Performance evaluation of the Arkray Adams HA-8160 HbA1c analyser.
Thevarajah, T Malathi; Nani, Nordin; Chew, Y Y
2008-12-01
HbA1c measurement is currently routinely used to predict long term outcome of diabetes, thus playing a fundamental role in the management of diabetes. The relationship between HbA1c value and long term diabetic complications has been established by a randomised control Diabetes Control and Complications Trial (DCCT) which used high performance liquid chromatography (HPLC) as a reference method for HbA1c assay. To ensure that HbA1c results from a variety HbA1c assay methods are similar to the DCCT values, the American Diabetes Association (ADA) recommended that all laboratories should use methods certified by the National Glycohemoglobin Standardization Programme (NGSP) with interassay coefficient variation (CV) of < 5% (ideally < 3%). The International Federation of Clinical Chemistry (IFCC) working group on HbA1c standardisation has set a CV < 2.5% as a criteria for its reference laboratories. To evaluate the performance of Arkray Adams HA-8160 HbA1c analyser which uses a cation exchange HPLC method and its correlation to HbA1c assay on Cobas Integra 800 which is an immunoturbidimetric method. For the imprecision study, patient samples and control material of two levels were analysed on HA-8160 analyser 20 times in a single run (within-run imprecision) and twice a day on five consecutive days (between-run imprecision). For the recovery study, two samples each with high and low values were selected and mixed in ratios of 1:3, 1:1 and 3:1, and were analysed by HA-8160. Sixty samples were analysed by both Cobas Integra 800 and HA-8160 for method comparison study. Ten uraemic samples and ten thalassaemic samples were assayed on Cobas Integra 800 and HA 8160 for interference study. Within-run CVs were 0.6% and 0.7% for medium and high value samples respectively, 0.6% and 0.7% for low and high level controls respectively. Between-run CVs were 0.5% and 0.4% for medium and high value samples respectively, 0.5% and 0.6% for low and high level controls respectively. The mean recovery was 100.1%. A good correlation between the 2 methods (Adams = 1.00 Cobas - 0.11, r = 0.98) was observed. The Akray Adams HA-8160 HbA1c analyser performed within the target CV of < 2.5% and showed a good correlation with the Cobas Integra 800.
Central Corneal Thickness Reproducibility among Ten Different Instruments.
Pierro, Luisa; Iuliano, Lorenzo; Gagliardi, Marco; Ambrosi, Alessandro; Rama, Paolo; Bandello, Francesco
2016-11-01
To assess agreement between one ultrasonic (US) and nine optical instruments for the measurement of central corneal thickness (CCT), and to evaluate intra- and inter-operator reproducibility. In this observational cross-sectional study, two masked operators measured CCT thickness twice in 28 healthy eyes. We used seven spectral-domain optical coherence tomography (SD-OCT) devices, one time-domain OCT, one Scheimpflug camera, and one US-based instrument. Inter- and intra-operator reproducibility was evaluated by intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measurements. We also tested how the devices disagreed regarding systemic bias and random error using a structural equation model. Mean CCT of all instruments ranged from 536 ± 42 μm to 577 ± 40 μm. An instrument-to-instrument correlation test showed high values among the 10 investigated devices (correlation coefficient range 0.852-0.995; p values <0.0001 in all cases). The highest correlation coefficient values were registered between 3D OCT-2000 Topcon-Spectral OCT/SLO Opko (0.995) and Cirrus HD-OCT Zeiss-RS-3000 Nidek (0.995), whereas the lowest were seen between SS-1000 CASIA and Spectral OCT/SLO Opko (0.852). ICC and CV showed excellent inter- and intra-operator reproducibility for all optic-based devices, except for the US-based device. Bland-Altman analysis demonstrated low mean biases between operators. Despite highlighting good intra- and inter-operator reproducibility, we found that a scale bias between instruments might interfere with thorough CCT monitoring. We suggest that optimal monitoring is achieved with the same operator and the same device.
Hansson, Nils Henrik; Harms, Hendrik Johannes; Kim, Won Yong; Nielsen, Roni; Tolbod, Lars P; Frøkiær, Jørgen; Bouchelouche, Kirsten; Poulsen, Steen Hvitfeldt; Wiggers, Henrik; Parner, Erik Thorlund; Sörensen, Jens
2018-05-31
Myocardial efficiency measured by 11 C-acetate positron emission tomography (PET) has successfully been used in clinical research to quantify mechanoenergetic coupling. The objective of this study was to establish the repeatability of myocardial external efficiency (MEE) and work metabolic index (WMI) by non-invasive concepts. Ten healthy volunteers (63 ± 4 years) were examined twice, one week apart, using 11 C-acetate PET, cardiovascular magnetic resonance (CMR), and echocardiography. Myocardial oxygen consumption from PET was combined with stroke work data from CMR, echocardiography, or PET to obtain MEE and WMI for each modality. Repeatability was estimated as the coefficient of variation (CV) between test and retest. MEE CMR , MEE Echo , and MEE PET values were 21.9 ± 2.7%, 16.4 ± 3.7%, and 23.8 ± 4.9%, respectively, P < .001. WMI CMR , WMI Echo , and WMI PET values were 4.42 ± 0.90, 4.07 ± 0.63, and 4.58 ± 1.13 mmHg × mL/m 2 × 10 6 , respectively, P = .45. Repeatability for MEE CMR was superior compared with MEE Echo but did not differ significantly compared with MEE PET (6.3% vs 12.9% and 9.4%, P = .04 and .25). CV values for WMI CMR , WMI Echo , and WMI PET were 10.0%, 14.8%, and 12.0%, respectively, (P = .53). Non-invasive measurements of MEE using 11 C-acetate PET are highly repeatable. A PET-only approach did not differ significantly from CMR/PET and might facilitate further clinical research due to lower costs and broader applicability.
Cirilli, Natalia; Raia, Valeria; Rocco, Ilaria; De Gregorio, Fabiola; Tosco, Antonella; Salvadori, Laura; Sepe, Angela Ornella; Buzzetti, Roberto; Minicuci, Nadia; Castaldo, Giuseppe
2018-04-02
The sweat test is one of the main diagnostic tools used in newborn screening programs and as a confirmatory test, in case of suspect of Cystic Fibrosis (CF). Since sweat chloride (Cl) concentration is also considered an appropriate parameter to explore the efficacy of CFTR modulators in clinical trials, it is crucial to evaluate the biological variability of this test in healthy and pathological conditions. The aim of this pilot study was to determine the intra-individual biological variability of sweat Cl, both in healthy individuals and CF patients and to assess its correlation with diet, season, and menstrual cycle. Thirty-five out of 36 selected subjects (6-18 years) were enrolled by 2 CF care centers and assigned to 3 cohorts: CF, CFTR-related disorder (CFTR-RD) and healthy volunteers. Each participant was subjected to eight sweat tests in different conditions and time of the year. Data were analyzed using linear mixed effects models for repeated measures, taking also into account intra-individual correlations. We observed a high intra-individual variability of sweat Cl, with the lowest mean CV% values among CF patients (20.21 in CF, 29.74 in CFTR-RD, and 31.15 in healthy subjects). Gender and diet had no influence on sweat Cl variability, nor had pubertal age and menstrual phase. Results of this pilot study confirmed that sweat Cl variability is high in CF patients, although non-CF individuals displayed even higher mean CV% values. Season significantly influenced sweat test values only in CF patients, likely due to changes in their hydration status. © 2018 Wiley Periodicals, Inc.
Statistical modeling and MAP estimation for body fat quantification with MRI ratio imaging
NASA Astrophysics Data System (ADS)
Wong, Wilbur C. K.; Johnson, David H.; Wilson, David L.
2008-03-01
We are developing small animal imaging techniques to characterize the kinetics of lipid accumulation/reduction of fat depots in response to genetic/dietary factors associated with obesity and metabolic syndromes. Recently, we developed an MR ratio imaging technique that approximately yields lipid/{lipid + water}. In this work, we develop a statistical model for the ratio distribution that explicitly includes a partial volume (PV) fraction of fat and a mixture of a Rician and multiple Gaussians. Monte Carlo hypothesis testing showed that our model was valid over a wide range of coefficient of variation of the denominator distribution (c.v.: 0-0:20) and correlation coefficient among the numerator and denominator (ρ 0-0.95), which cover the typical values that we found in MRI data sets (c.v.: 0:027-0:063, ρ: 0:50-0:75). Then a maximum a posteriori (MAP) estimate for the fat percentage per voxel is proposed. Using a digital phantom with many PV voxels, we found that ratio values were not linearly related to PV fat content and that our method accurately described the histogram. In addition, the new method estimated the ground truth within +1.6% vs. +43% for an approach using an uncorrected ratio image, when we simply threshold the ratio image. On the six genetically obese rat data sets, the MAP estimate gave total fat volumes of 279 +/- 45mL, values 21% smaller than those from the uncorrected ratio images, principally due to the non-linear PV effect. We conclude that our algorithm can increase the accuracy of fat volume quantification even in regions having many PV voxels, e.g. ectopic fat depots.
Hirota, Mitsuru; Zhang, Pengcheng; Gu, Song; Shen, Haihua; Kuriyama, Takeo; Li, Yingnian; Tang, Yanhong
2010-07-01
Characterizing the spatial variation in the CO2 flux at both large and small scales is essential for precise estimation of an ecosystem's CO2 sink strength. However, little is known about small-scale CO2 flux variations in an ecosystem. We explored these variations in a Kobresia meadow ecosystem on the Qinghai-Tibetan plateau in relation to spatial variability in species composition and biomass. We established 14 points and measured net ecosystem production (NEP), gross primary production (GPP), and ecosystem respiration (Re) in relation to vegetation biomass, species richness, and environmental variables at each point, using an automated chamber system during the 2005 growing season. Mean light-saturated NEP and GPP were 30.3 and 40.5 micromol CO2 m(-2) s(-1) [coefficient of variation (CV), 42.7 and 29.4], respectively. Mean Re at 20 degrees C soil temperature, Re(20), was -10.9 micromol CO2 m(-2) s(-1) (CV, 27.3). Re(20) was positively correlated with vegetation biomass. GPP(max) was positively correlated with species richness, but 2 of the 14 points were outliers. Vegetation biomass was the main determinant of spatial variation of Re, whereas species richness mainly affected that of GPP, probably reflecting the complexity of canopy structure and light partitioning in this small grassland patch.
Describing Chinese hospital activity with diagnosis related groups (DRGs). A case study in Chengdu.
Gong, Zhiping; Duckett, Stephen J; Legge, David G; Pei, Likun
2004-07-01
To examine the applicability of an Australian casemix classification system to the description of Chinese hospital activity. A total of 161,478 inpatient episodes from three Chengdu hospitals with demographic, diagnosis, procedure and billing data for the year 1998/1999, 1999/2000 and 2000/2001 were grouped using the Australian refined-diagnosis related groups (AR-DRGs) (version 4.0) grouper. Reduction in variance (R2) and coefficient of variation (CV). Untrimmed reduction in variance (R2) was 0.12 and 0.17 for length of stay (LOS) and cost respectively. After trimming, R2 values were 0.45 and 0.59 for length of stay and cost respectively. The Australian refined DRGs provide a good basis for developing a Chinese grouper.
Nikolakakis, I; Aragon, O B; Malamataris, S
1998-07-01
The purpose of this study was to compare some indicators of capsule-filling performance, as measured by tapped density under different conditions, and elucidate possible quantitative relationships between variation of capsule fill-weight (%CV) and gravitational and inter-particle forces (attractive or frictional) derived from measurements of particle size, true density, low compression and tensile strength. Five common pharmaceutical diluents (lactose, maize starch, talc, Emcocel and Avicel) were investigated and two capsule-filling methods (pouring powder and dosator nozzle) were employed. It was found that for the pouring-type method the appropriateness of Hausner's ratio (HR), Carr's compressibility index (CC%) and Kawakita's constant (alpha) as indicators of capsule fill-weight variation decreases in the order alpha > CC% > HR; the appropriateness of these indicators also decreases with increasing cylinder size and with impact velocity during tapping. For the dosator-type method the appropriateness of the indicators decreases in the order HR > CC% > alpha, the opposite of that for the pouring-type method; the appropriateness of the indicators increases with decreasing cylinder size and impact velocity. The relationship between %CV and the ratio of inter-particle attractive to gravitational forces calculated from measurements of particle size and true density (Fvdw/Wp) was more significant for the pouring-type capsule-filling method. For the dosator-type method a significant relationship (1% level) was found between %CV and the product of Fvdw/Wp and a function expressing the increase, with packing density (p(f)), in the ratio of frictional to attractive inter-particle forces derived from compression (P) and tensile-strength (T) testing, d(log(P/T))/d(p(f)). The value of tapped density in predictions of capsule-filling performance is affected by the testing conditions in a manner depending on the filling method applied. For the pouring-type method predictions can be based on the ratio of attractive (inter-particle) to gravitational forces, whereas for the dosator-type method the contribution of frictional and attractive forces should, because of packing density change, also be taken into account.
Positional dependence of particles in microfludic impedance cytometry.
Spencer, Daniel; Morgan, Hywel
2011-04-07
Single cell impedance cytometry is a label-free electrical analysis method that requires minimal sample preparation and has been used to count and discriminate cells on the basis of their impedance properties. This paper shows experimental and numerically simulated impedance signals for test particles (6 μm diameter polystyrene) flowing through a microfluidic channel. The variation of impedance signal with particle position is mapped using numerical simulation and these results match closely with experimental data. We demonstrate that for a nominal 40 μm × 40 μm channel, the impedance signal is independent of position over the majority of the channel area, but shows large experimentally verifiable variation at extreme positions. The parabolic flow profile in the channel ensures that most of the sample flows through the area of uniform signal. At high flow rates inertial focusing is observed; the particles flow in equal numbers through two equilibrium positions reducing the coefficient of variance (CV) in the impedance signals to negligible values.
Kaku, Kohei; Lee, Jisoo; Mattheus, Michaela; Kaspers, Stefan; George, Jyothis; Woerle, Hans-Juergen
2017-01-25
In the EMPA-REG OUTCOME ® trial, empagliflozin added to standard of care reduced the risk of 3-point major adverse cardiovascular (CV) events (3-point MACE: composite of CV death, non-fatal myocardial infarction, or non-fatal stroke) by 14%, CV death by 38%, hospitalization for heart failure by 35%, and all-cause mortality by 32% in patients with type 2 diabetes (T2DM) and established CV disease. We investigated the effects of empagliflozin in patients of Asian race.Methods and Results:Patients were randomized to receive empagliflozin 10 mg, empagliflozin 25 mg, or placebo. Of 7,020 patients treated, 1,517 (21.6%) were of Asian race. The reduction in 3-point MACE in Asian patients was consistent with the overall population: 3-point MACE occurred in 79/1,006 patients (7.9%) in the pooled empagliflozin group vs. 58/511 patients (11.4%) in the placebo group (hazard ratio: 0.68 [95% confidence interval: 0.48-0.95], P-value for treatment by race interaction (Asian, White, Black/African-American): 0.0872). The effects of empagliflozin on the components of MACE, all-cause mortality, and heart failure outcomes in Asian patients were consistent with the overall population (P-values for interaction by race >0.05). The adverse event profile of empagliflozin in Asian patients was similar to the overall trial population. Reductions in the risk of CV outcomes and mortality with empagliflozin in Asian patients with T2DM and established CV disease were consistent with the overall trial population.
Wang, Ran; Gamon, John A; Cavender-Bares, Jeannine; Townsend, Philip A; Zygielbaum, Arthur I
2018-03-01
Remote sensing has been used to detect plant biodiversity in a range of ecosystems based on the varying spectral properties of different species or functional groups. However, the most appropriate spatial resolution necessary to detect diversity remains unclear. At coarse resolution, differences among spectral patterns may be too weak to detect. In contrast, at fine resolution, redundant information may be introduced. To explore the effect of spatial resolution, we studied the scale dependence of spectral diversity in a prairie ecosystem experiment at Cedar Creek Ecosystem Science Reserve, Minnesota, USA. Our study involved a scaling exercise comparing synthetic pixels resampled from high-resolution images within manipulated diversity treatments. Hyperspectral data were collected using several instruments on both ground and airborne platforms. We used the coefficient of variation (CV) of spectral reflectance in space as the indicator of spectral diversity and then compared CV at different scales ranging from 1 mm 2 to 1 m 2 to conventional biodiversity metrics, including species richness, Shannon's index, Simpson's index, phylogenetic species variation, and phylogenetic species evenness. In this study, higher species richness plots generally had higher CV. CV showed higher correlations with Shannon's index and Simpson's index than did species richness alone, indicating evenness contributed to the spectral diversity. Correlations with species richness and Simpson's index were generally higher than with phylogenetic species variation and evenness measured at comparable spatial scales, indicating weaker relationships between spectral diversity and phylogenetic diversity metrics than with species diversity metrics. High resolution imaging spectrometer data (1 mm 2 pixels) showed the highest sensitivity to diversity level. With decreasing spatial resolution, the difference in CV between diversity levels decreased and greatly reduced the optical detectability of biodiversity. The optimal pixel size for distinguishing α diversity in these prairie plots appeared to be around 1 mm to 10 cm, a spatial scale similar to the size of an individual herbaceous plant. These results indicate a strong scale-dependence of the spectral diversity-biodiversity relationships, with spectral diversity best able to detect a combination of species richness and evenness, and more weakly detecting phylogenetic diversity. These findings can be used to guide airborne studies of biodiversity and develop more effective large-scale biodiversity sampling methods. ©2018 The Authors Ecological Applications published by Wiley Periodicals, Inc. on behalf of Ecological Society of America.
NASA Astrophysics Data System (ADS)
Confortin, Daria; Neevel, Han; Brustolon, Marina; Franco, Lorenzo; Kettelarij, Albert J.; Williams, Renè M.; van Bommel, Maarten R.
2010-06-01
The photo-fading of crystal violet (CV), one of the earliest synthetic dyes and an ink component, is examined both in solution and on paper. Aqueous solutions of CV were exposed to UV light (365nm) and samples were taken at constant time intervals and analysed with a High Performance Liquid Chromatography-Photo Diode Array (HPLC-PDA) and Liquid Chromatography-Mass Spectroscopy (LC-MS). Demethylation products were positively identified. Also, deamination probably occurred. The oxidation at the central carbon likely generates Michler's ketone (MK) or its derivatives, but still needs confirmation. To study CV on paper, Whatman paper was immersed in CV and exposed to UV light. Before and after different irradiation periods, reflectance spectra were recorded with Fibre Optic Reflectance Spectrophotometry (FORS). A decrease in CV concentration and a change in aggregation type for CV molecules upon irradiation was observed. Colorimetric L*a*b* values before and during irradiation were also measured. Also, CV was extracted from paper before and after different irradiation periods and analysed with HPLC-PDA. Photo-fading of CV on paper produced the same products as in solution, at least within the first 100 hours of irradiation. Finally, a photo-fading of CV in the presence of MK on Whatman paper was performed. It was demonstrated that MK both accelerates CV degradation and is consumed during the reaction. The degradation pathway identified in this work is suitable for explaining the photo/fading of other dyes belonging to the triarylmethane group.
Mild cognitive impairment in symptomatic and asymptomatic cerebrovascular disease.
Popović, Irena Martinić; Serić, Vesna; Demarin, Vida
2007-06-15
We tried to evaluate and to compare usefulness of two brief cognitive tests in early detection of cognitive decline in subjects with increased cerebrovascular (CV) risk. As CV risk factors are recognised as important in etiology of dementia, we also aimed to determine the possible associations of specific CV risk factors and cognitive results. Patients (PGs) with first-ever stroke or TIA (N=110) and CV symptoms-free controls (CGs) with CV risk factors present (N=45) matched for age, gender and education level were tested using Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment (MoCA) on admission, at three- and six-month points. In all subjects, detailed CV risk factors profile was assessed. We observed the decrement in cognitive performance during the six-month study period in both groups, more evident if MoCA (p<0.001) than if MMSE was used (p=0.022). Six months after first stroke/TIA 83.6% PGs scored below normal range on MoCA. In PGs, positive associations for cognitive decrement and multiple CV risk factors (>2) were found (p=0.034 for MMSE; p=0.002 for MoCA). In CGs, positive associations were found for cognitive decrement and arterial hypertension with increased IMT values (p<0.001 for MMSE) and for multiple CV risk factors and arterial hypertension (p=0.003 for MoCA). The use of MoCA could aid to early recognition of cognitive deficits in persons with increased CV risk. Individuals with multiple CV risk factors seem to have increased risk of cognitive decline.
Reliability of bounce drop jump parameters within elite male rugby players.
Costley, Lisa; Wallace, Eric; Johnston, Michael; Kennedy, Rodney
2017-07-25
The aims of the study were to investigate the number of familiarisation sessions required to establish reliability of the bounce drop jump (BDJ) and subsequent reliability once familiarisation is achieved. Seventeen trained male athletes completed 4 BDJs in 4 separate testing sessions. Force-time data from a 20 cm BDJ was obtained using two force plates (ensuring ground contact < 250 ms). Subjects were instructed to 'jump for maximal height and minimal contact time' while the best and average of four jumps were compared. A series of performance variables were assessed in both eccentric and concentric phases including jump height, contact time, flight time, reactive strength index (RSI), peak power, rate of force development (RFD) and actual dropping height (ADH). Reliability was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV) while familiarisation was assessed using a repeated measures analysis of variance (ANOVA). The majority of DJ parameters exhibited excellent reliability with no systematic bias evident, while the average of 4 trials provided greater reliability. With the exception of vertical stiffness (CV: 12.0 %) and RFD (CV: 16.2 %) all variables demonstrated low within subject variation (CV range: 3.1 - 8.9 %). Relative reliability was very poor for ADH, with heights ranging from 14.87 - 29.85 cm. High levels of reliability can be obtained from the BDJ with the exception of vertical stiffness and RFD, however, extreme caution must be taken when comparing DJ results between individuals and squads due to large discrepancies between actual drop height and platform height.
2013-06-01
distribution is unlimited 12b. DISTRIBUTION CODE A 13. ABSTRACT (maximum 200 words) Some major defense acquisition programs (MDAPs) are cancelled...68 VI. PRACTICAL IMPLICATIONS FOR DEFENSE ACQUISITION .....................73 A . OVERVIEW...Contract Performance Report C /SCSC Cost/Schedule Control Systems Criteria CV Cost Variance CV % Cost Variance Percentage DAE Defense Acquisition
8760-Based Method for Representing Variable Generation Capacity Value in Capacity Expansion Models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frew, Bethany A
Capacity expansion models (CEMs) are widely used to evaluate the least-cost portfolio of electricity generators, transmission, and storage needed to reliably serve load over many years or decades. CEMs can be computationally complex and are often forced to estimate key parameters using simplified methods to achieve acceptable solve times or for other reasons. In this paper, we discuss one of these parameters -- capacity value (CV). We first provide a high-level motivation for and overview of CV. We next describe existing modeling simplifications and an alternate approach for estimating CV that utilizes hourly '8760' data of load and VG resources.more » We then apply this 8760 method to an established CEM, the National Renewable Energy Laboratory's (NREL's) Regional Energy Deployment System (ReEDS) model (Eurek et al. 2016). While this alternative approach for CV is not itself novel, it contributes to the broader CEM community by (1) demonstrating how a simplified 8760 hourly method, which can be easily implemented in other power sector models when data is available, more accurately captures CV trends than a statistical method within the ReEDS CEM, and (2) providing a flexible modeling framework from which other 8760-based system elements (e.g., demand response, storage, and transmission) can be added to further capture important dynamic interactions, such as curtailment.« less
Asfaram, Arash; Ghaedi, Mehrorang; Ghezelbash, Gholam Reza; Pepe, Francesco
2017-05-01
Simultaneous biosorption of malachite green (MG) and crystal violet (CV) on biosorbent Yarrowia lipolytica ISF7 was studied. An appropriate derivative spectrophotometry technique was used to evaluate the concentration of each dye in binary solutions, despite significant interferences in visible light absorbances. The effects of pH, temperature, growth time, initial MG and CV concentration in batch experiments were assessed using Design of Experiment (DOE) according to central composite second order response surface methodology (RSM). The analysis showed that the greatest biosorption efficiency (>99% for both dyes) can be obtained at pH 7.0, T=28°C, 24h mixing and 20mgL -1 initial concentrations for both MG and CV dyes. The quadratic constructed equation ability for fitting experimental data is judged based on criterions like R 2 values, significant p and lack-of-fit value strongly confirm its high adequacy and applicability for prediction of revel behavior of the system under study. The proposed model showed very high correlation coefficients (R 2 =0.9997 for CV and R 2 =0.9989 for MG), while supported by closeness of predicted and experimental value. A kinetic analysis was carried out, showing that for both dyes a pseudo-second order kinetic model adequately describes the available data. The Langmuir isotherm model in single and binary components has better performance for description of dyes biosorption with maximum monolayer biosorption capacity of 59.4 and 62.7mgg -1 in single component and 46.4 and 50.0mgg -1 for CV and MB in binary components, respectively. The surface structure of biosorbents and the possible biosorbents-dyes interactions between were also evaluated by Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The values of thermodynamic parameters including ΔG° and ΔH° strongly confirm which method is spontaneous and endothermic. Copyright © 2017. Published by Elsevier Inc.
Umpierres, Cibele S; Prola, Lizie D T; Adebayo, Matthew A; Lima, Eder C; Dos Reis, Glaydson S; Kunzler, Diego D F; Dotto, G L; Arenas, Leliz T; Benvenutti, Edilson V
2017-03-01
In this work, SiO 2 /Nb 2 O 5 (SiNb) material was prepared using sol-gel method and employed as adsorbent for removal of crystal violet dye (CV). The material was characterized using nitrogen adsorption-desorption isotherms, FTIR spectroscopy, pH pzc , and SEM-EDS. The analysis of N 2 isotherms revealed the presence of micro- and mesopores in the SiNb sample with specific surface area as high as 747 m 2 g -1 . For the CV adsorption process, variations of several parameters such as of pH, temperature, contact time, and concentration of dye of the process were evaluated. The optimum initial pH of the CV dye solution was 7.0. The adsorption kinetic and equilibrium data for CV adsorption were suitably represented by the general-order and Liu models, respectively. The maximum adsorption capacity of the CV dye by SiNb was achieved at 303 K, which attained 116 mg g -1 at this temperaure. Dye effluents were simulated and used to check the applicability of the SiNb material for treatment of effluents - the material showed very good efficiency for decolorization of dye effluents.
Corneal endothelial cell density and morphology in Phramongkutklao Hospital
Sopapornamorn, Narumon; Lekskul, Manapon; Panichkul, Suthee
2008-01-01
Objective To describe the corneal endothelial density and morphology in patients of Phramongkutklao Hospital and the relationship between endothelial cell parameters and other factors. Methods Four hundred and four eyes of 202 volunteers were included. Noncontact specular microscopy was performed after taking a history and testing the visual acuity, intraocular pressure measurement, Schirmer’s test and routine eye examination by slit lamp microscope. The studied parameters included mean endothelial cell density (MCD), coefficient of variation (CV), and percentage of hexagonality. Results The mean age of volunteers was 45.73 years; the range being 20 to 80 years old. Their MCD (SD), mean percentage of CV (SD) and mean (SD) percentage of hexagonality were 2623.49(325) cell/mm2, 39.43(8.23)% and 51.50(10.99)%, respectively. Statistically, MCD decreased significantly with age (p < 0.01). There was a significant difference in the percentage of CV between genders. There was no statistical significance between parameters and other factors. Conclusion The normative data of the corneal endothelium of Thai eyes indicated that, statistically, MCD decreased significantly with age. Previous studies have reported no difference in MCD, percentage of CV, and percentage of hexagonality between gender. Nevertheless, significantly different percentages of CV between genders were presented in this study. PMID:19668398
Detection of a novel circovirus in mute swans (Cygnus olor) by using nested broad-spectrum PCR.
Halami, M Y; Nieper, H; Müller, H; Johne, R
2008-03-01
Circoviruses are the causative agents of acute and chronic diseases in several animal species. Clinical symptoms of circovirus infections range from depression and diarrhoea to immunosuppression and feather disorders in birds. Eleven different members of the genus Circovirus are known so far, which infect pigs and birds in a species-specific manner. Here, a nested PCR was developed for the detection of a broad range of different circoviruses in clinical samples. Using this assay, a novel circovirus was detected in mute swans (Cygnus olor) found dead in Germany in 2006. Sequence analysis of the swan circovirus (SwCV) genome, amplified by multiply primed rolling-circle amplification and PCR, indicates that SwCV is a distinct virus most closely related to the goose circovirus (73.2% genome sequence similarity). Sequence variations between SwCV genomes derived from two different individuals were high (15.5% divergence) and mainly confined to the capsid protein-encoding region. By PCR testing of 32 samples derived from swans found dead in two different regions of Germany, detection rates of 20.0 and 77.3% were determined, thus indicating a high incidence of SwCV infection. The clinical significance of SwCV infection, however, needs to be investigated further.
Just, Sarah; Toschkoff, Gregor; Funke, Adrian; Djuric, Dejan; Scharrer, Georg; Khinast, Johannes; Knop, Klaus; Kleinebudde, Peter
2013-11-30
The objective of this study was to enhance the inter-tablet coating uniformity in an active coating process at lab and pilot scale by statistical design of experiments. The API candesartan cilexetil was applied onto gastrointestinal therapeutic systems containing the API nifedipine to obtain fixed dose combinations of these two drugs with different release profiles. At lab scale, the parameters pan load, pan speed, spray rate and number of spray nozzles were examined. At pilot scale, the parameters pan load, pan speed, spray rate, spray time, and spray pressure were investigated. A low spray rate and a high pan speed improved the coating uniformity at both scales. The number of spray nozzles was identified as the most influential variable at lab scale. With four spray nozzles, the highest CV value was equal to 6.4%, compared to 13.4% obtained with two spray nozzles. The lowest CV of 4.5% obtained with two spray nozzles was further reduced to 2.3% when using four spray nozzles. At pilot scale, CV values between 2.7% and 11.1% were achieved. Since the test of uniformity of dosage units accepts CV values of up to 6.25%, this active coating process is well suited to comply with the pharmacopoeial requirements. Copyright © 2013 Elsevier B.V. All rights reserved.
Huang, Ni; Wang, Li; Hu, Yongsen; Tian, Haifeng; Niu, Zheng
2016-01-01
Spatial variation of soil respiration (Rs) in cropland ecosystems must be assessed to evaluate the global terrestrial carbon budget. This study aims to explore the spatial characteristics and controlling factors of Rs in a cropland under winter wheat and summer maize rotation in the North China Plain. We collected Rs data from 23 sample plots in the cropland. At the late jointing stage, the daily mean Rs of summer maize (4.74 μmol CO2 m-2 s-1) was significantly higher than that of winter wheat (3.77μmol CO2 m-2 s-1). However, the spatial variation of Rs in summer maize (coefficient of variation, CV = 12.2%) was lower than that in winter wheat (CV = 18.5%). A similar trend in CV was also observed for environmental factors but not for biotic factors, such as leaf area index, aboveground biomass, and canopy chlorophyll content. Pearson's correlation analyses based on the sampling data revealed that the spatial variation of Rs was poorly explained by the spatial variations of biotic factors, environmental factors, or soil properties alone for winter wheat and summer maize. The similarly non-significant relationship was observed between Rs and the enhanced vegetation index (EVI), which was used as surrogate for plant photosynthesis. EVI was better correlated with field-measured leaf area index than the normalized difference vegetation index and red edge chlorophyll index. All the data from the 23 sample plots were categorized into three clusters based on the cluster analysis of soil carbon/nitrogen and soil organic carbon content. An apparent improvement was observed in the relationship between Rs and EVI in each cluster for both winter wheat and summer maize. The spatial variation of Rs in the cropland under winter wheat and summer maize rotation could be attributed to the differences in spatial variations of soil properties and biotic factors. The results indicate that applying cluster analysis to minimize differences in soil properties among different clusters can improve the role of remote sensing data as a proxy of plant photosynthesis in semi-empirical Rs models and benefit the acquisition of Rs in cropland ecosystems at large scales.
Crespo, André L B; Spencer, Terence A; Nekl, Emily; Pusztai-Carey, Marianne; Moar, William J; Siegfried, Blair D
2008-01-01
Standardization of toxin preparations derived from Bacillus thuringiensis (Berliner) used in laboratory bioassays is critical for accurately assessing possible changes in the susceptibility of field populations of target pests. Different methods were evaluated to quantify Cry1Ab, the toxin expressed by 80% of the commercially available transgenic maize that targets the European corn borer, Ostrinia nubilalis (Hübner). We compared three methods of quantification on three different toxin preparations from independent sources: enzyme-linked immunosorbent assay (ELISA), sodium dodecyl sulfate-polyacrylamide gel electrophoresis and densitometry (SDS-PAGE/densitometry), and the Bradford assay for total protein. The results were compared to those obtained by immunoblot analysis and with the results of toxin bioassays against susceptible laboratory colonies of O. nubilalis. The Bradford method resulted in statistically higher estimates than either ELISA or SDS-PAGE/densitometry but also provided the lowest coefficients of variation (CVs) for estimates of the Cry1Ab concentration (from 2.4 to 5.4%). The CV of estimates obtained by ELISA ranged from 12.8 to 26.5%, whereas the CV of estimates obtained by SDS-PAGE/densitometry ranged from 0.2 to 15.4%. We standardized toxin concentration by using SDS-PAGE/densitometry, which is the only method specific for the 65-kDa Cry1Ab protein and is not confounded by impurities detected by ELISA and Bradford assay for total protein. Bioassays with standardized Cry1Ab preparations based on SDS-PAGE/densitometry showed no significant differences in LC(50) values, although there were significant differences in growth inhibition for two of the three Cry1Ab preparations. However, the variation in larval weight caused by toxin source was only 4% of the total variation, and we conclude that standardization of Cry1Ab production and quantification by SDS-PAGE/densitometry may improve data consistency in monitoring efforts to identify changes in insect susceptibility to Cry1Ab.
Doncaster, Greg; Unnithan, Viswanath
2017-07-12
To assess the between-game variation in measures of physical performance during 11 v 11 soccer match-play, over a short period of time, in highly trained youth soccer players. A single cohort observational study design was employed. Physical match performance data were collected from 17 male, highly trained youth soccer players (age: 13.3 ± 0.4 y) over three, 2 x 20min, 11 v 11 matches. Using 10 Hz GPS, the variables selected for analyses were total distance (TD), high-speed running (HSR), very high-speed running (VHSR), number of high-speed running efforts (HSReff) and number of very high-speed running efforts (VHSReff). Match data was also separated into cumulative 5 min epochs, to identify the peak 5 min epoch and the mean of the cumulative 5 min epochs for each match. Variability was quantified using the coefficient of variation (CV), Standard error of measurement (SEM) and intra-class correlation coefficient (ICC). Between- and within-player smallest worthwhile changes (SWC) were also calculated for each variable to aid in the interpretation of the data. Analysis of the variance between games reported a low CV for TD (3.8%) but larger CVs for HSR (33.3%), HSReff (35.4%) and VHSR and VHSReff (59.6 and 57.4 %, respectively). Analysis of 5 min epochs (peak and average) found an increase in the CVs beyond that of the values reported for the whole match. Between-player SWC in high intensity physical performance data ranged from 24.7 - 42.4 %, whereas within-player SWC ranged from 1.2 - 79.9%. The between-game variability of high and very high intensity activities in youth soccer players, across three soccer matches over a short period of time (2 weeks), is relatively 'large' and specific to the individual, thus highlighting the need for caution when interpreting physical performance data between games and players.
Detection of Penicillinase in Milk by Sandwich ELISA Based Polyclonal and Monoclonal Antibody.
Zhao, Yinli; Li, Guoxi
2016-01-01
A sandwich ELISA has been developed using polyclonal and monoclonal antibody for the determination of penicillinase in milk. For this purpose, specific polyclonal and monoclonal antibodies against penicillinase were generated and characterized. Using penicillinase standards prepared from 1-128 ng/mL, the method indicated that the detection limit of the sandwich ELISA, as measured in an ELISA plate reader, was as low as 0.86 ng/mL of penicillinase. For determine the accuracy, raw milk containing 2, 8, 32, and 64 ng/mL of penicillinase were tested by sandwich ELISA. Recoveries were from 93-97.5%, and the coefficient of variation [CV (%)] were from 5.55-8.38%. For interassay reproducibility, recoveries were from 89.5-95.1%, the coefficient of variation [CV (%)] were from 5.26-9.58%. This sandwich ELISA provides a useful screening method for quantitative detection of penicillinase in milk.
Within-Session Stability of Short-Term Heart Rate Variability Measurement
2016-01-01
Abstract The primary aim of this study was to assess the retest stability of the short-term heart rate variability (HRV) measurement performed within one session and without the use of any intervention. Additionally, a precise investigation of the possible impact of intrinsic biological variation on HRV reliability was also performed. First, a single test-retest HRV measurement was conducted with 20-30 min apart from one another. Second, the HRV measurement was repeated in ten non-interrupted consecutive intervals. The lowest typical error (CV = 21.1%) was found for the square root of the mean squared differences of successive RR intervals (rMSSD) and the highest for the low frequency power (PLF) (CV = 93.9%). The standardized changes in the mean were trivial to small. The correlation analysis revealed the highest level for ln rMSSD (ICC = 0.87), while ln PLF represented the worst case (ICC = 0.59). The reliability indices for ln rMSSD in 10 consecutive intervals improved (CV = 9.9%; trivial standardized changes in the mean; ICC = 0.96). In conclusion, major differences were found in the reliability level between the HRV indices. The rMSSD demonstrated the highest reliability level. No substantial influence of intrinsic biological variation on the HRV reliability was observed. PMID:28149345
Li, Min; Qi, Tao; Bernabé, Yves; Zhao, Jinzhou; Wang, Ying; Wang, Dong; Wang, Zheming
2018-02-28
We used a time domain random walk approach to simulate passive solute transport in networks. In individual pores, solute transport was modeled as a combination of Poiseuille flow and Taylor dispersion. The solute plume data were interpreted via the method of moments. Analysis of the first and second moments showed that the longitudinal dispersivity increased with increasing coefficient of variation of the pore radii CV and decreasing pore coordination number Z. The third moment was negative and its magnitude grew linearly with time, meaning that the simulated dispersion was intrinsically non-Fickian. The statistics of the Eulerian mean fluid velocities [Formula: see text], the Taylor dispersion coefficients [Formula: see text] and the transit times [Formula: see text] were very complex and strongly affected by CV and Z. In particular, the probability of occurrence of negative velocities grew with increasing CV and decreasing Z. Hence, backward and forward transit times had to be distinguished. The high-τ branch of the transit-times probability curves had a power law form associated to non-Fickian behavior. However, the exponent was insensitive to pore connectivity, although variations of Z affected the third moment growth. Thus, we conclude that both the low- and high-τ branches played a role in generating the observed non-Fickian behavior.
WE-G-18C-05: Characterization of Cross-Vendor, Cross-Field Strength MR Image Intensity Variations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paulson, E; Prah, D
2014-06-15
Purpose: Variations in MR image intensity and image intensity nonuniformity (IINU) can challenge the accuracy of intensity-based image segmentation and registration algorithms commonly applied in radiotherapy. The goal of this work was to characterize MR image intensity variations across scanner vendors and field strengths commonly used in radiotherapy. Methods: ACR-MRI phantom images were acquired at 1.5T and 3.0T on GE (450w and 750, 23.1), Siemens (Espree and Verio, VB17B), and Philips (Ingenia, 4.1.3) scanners using commercial spin-echo sequences with matched parameters (TE/TR: 20/500 ms, rBW: 62.5 kHz, TH/skip: 5/5mm). Two radiofrequency (RF) coil combinations were used for each scanner: bodymore » coil alone, and combined body and phased-array head coils. Vendorspecific B1- corrections (PURE/Pre-Scan Normalize/CLEAR) were applied in all head coil cases. Images were transferred offline, corrected for IINU using the MNI N3 algorithm, and normalized. Coefficients of variation (CV=σ/μ) and peak image uniformity (PIU = 1−(Smax−Smin)/(Smax+Smin)) estimates were calculated for one homogeneous phantom slice. Kruskal-Wallis and Wilcoxon matched-pairs tests compared mean MR signal intensities and differences between original and N3 image CV and PIU. Results: Wide variations in both MR image intensity and IINU were observed across scanner vendors, field strengths, and RF coil configurations. Applying the MNI N3 correction for IINU resulted in significant improvements in both CV and PIU (p=0.0115, p=0.0235). However, wide variations in overall image intensity persisted, requiring image normalization to improve consistency across vendors, field strengths, and RF coils. These results indicate that B1- correction routines alone may be insufficient in compensating for IINU and image scaling, warranting additional corrections prior to use of MR images in radiotherapy. Conclusions: MR image intensities and IINU vary as a function of scanner vendor, field strength, and RF coil configuration. A two-step strategy consisting of MNI N3 correction followed by normalization was required to improve MR image consistency. Funding provided by Advancing a Healthier Wisconsin.« less
Nutritional evaluation of commercial dry dog foods by near infrared reflectance spectroscopy.
Alomar, D; Hodgkinson, S; Abarzúa, D; Fuchslocher, R; Alvarado, C; Rosales, E
2006-06-01
Near infrared reflectance spectroscopy (NIRS) was used to predict the nutritional value of dog foods sold in Chile. Fifty-nine dry foods for adult and growing dogs were collected, ground and scanned across the visible/NIR range and subsequently analysed for dry matter (DM), crude protein (CP), crude fibre (CF), total fat, linoleic acid, gross energy (GE), estimated metabolizable energy (ME) and several amino acids and minerals. Calibration equations were developed by modified partial least squares regression, and tested by cross-validation. Standard error of cross validation (SE(CV)) and coefficient of determination of cross validation (SE(CV)) were used to select best equations. Equations with good predicting accuracy were obtained for DM, CF, CP, GE and fat. Corresponding values for and SE(CV) were 0.96 and 1.7 g/kg, 0.91 and 3.1 g/kg, 0.99 and 5.0 g/kg, 0.93 and 0.26 MJ/kg, 0.89 and 12.4 g/kg. Several amino acids were also well predicted, such as arginine, leucine, isoleucine, phenylalanine-tyrosine (combined), threonine and valine, with values for and SE(CV) (g/kg) of 0.89 and 0.9, 0.94 and 1.3, 0.91 and 0.5, 0.95 and 0.9, 0.91 and 0.5, 0.93 and 0.5. Intermediate values, appropriate for ranking purposes, were obtained for ME, histidine, lysine and methionine-cysteine. Tryptophan, minerals or linoleic acid were not acceptably predicted, irrespective of the mathematical treatment applied. It is concluded that NIR can be successfully used to predict important nutritional characteristics of commercial dog foods.
Brokordt, Katherina B.; González, Roxana C.; Farías, William J.; Winkler, Federico M.
2015-01-01
Assessing components of the immune system may reflect disease resistance. In some invertebrates, heat shock proteins (HSPs) are immune effectors and have been described as potent activators of the innate immune response. Several diseases have become a threat to abalone farming worldwide; therefore, increasing disease resistance is considered to be a long-term goal for breeding programs. A trait will respond to selection only if it is determined partially by additive genetic variation. The aim of this study was to estimate the heritability (h 2) and the additive genetic coefficient of variation (CV A) of HSP70 as a component of innate immunity of the abalone Haliotis rufescens, in order to assess its potential response to selection. These genetic components were estimated for the variations in the intracellular (in haemocytes) and extracellular (serum) protein levels of HSP70 in response to an immunostimulant agent in 60 full-sib families of H. rufescens. Levels of HSP70 were measured twice in the same individuals, first when they were young and again when they were pre-harvest adults, to estimate the repeatability (R), the h 2 and the potential response to selection of these traits at these life stages. High HSP70 levels were observed in abalones subjected to immunostimulation in both the intracellular and extracellular haemolymph fractions. This is the first time that changes in serum levels of HSP70 have been reported in response to an immune challenge in molluscs. HSP70 levels in both fractions and at both ages showed low h 2 and R, with values that were not significantly different from zero. However, HSP70 induced levels had a CV A of 13.3–16.2% in young adults and of 2.7–8.1% in pre-harvest adults. Thus, despite its low h 2, HSP70 synthesis in response to an immune challenge in red abalone has the potential to evolve through selection because of its large phenotypic variation and the presence of additive genetic variance, especially in young animals. PMID:26529324
Perry, Guy M. L.; Scheinman, Steven J.; Asplin, John R.
2013-01-01
Background/Aims Our work in a rodent model of urinary calcium suggests genetic and gender effects on increased residual variability in urine chemistries. Based on these findings, we hypothesized that sex would similarly be associated with residual variation in human urine solutes. Sex-related effects on residuals might affect the establishment of physiological baselines and error in medical assays. Methods We tested the effects of sex on residual variation in urine chemistry by estimating coefficients of variation (CV) for urinary solutes in paired sequential 24-h urines (≤72 hour interval) in 6,758 females and 9,024 males aged 16–80 submitted to a clinical laboratory. Results Females had higher CVs than males for urinary phosphorus overall at the False Discovery Rate (P<0.01). There was no effect of sex on CV for calcium (P>0.3). Males had higher CVs for citrate (P<0.01) from ages 16–45 and females higher CVs for citrate (P<0.01) from ages 56–80, suggesting effects of an extant oestral cycle on residual variance. Conclusions Our findings indicate the effects of sex on residual variance of the excretion of urinary solutes including phosphorus and citrate; differences in CV by sex might reflect dietary lability, differences in the fidelity of reporting or genetic differentiation in renal solute consistency. Such an effect could complicate medical analysis by the addition of random error to phenotypic assays. Renal analysis might require explicit incorporation of heterogeneity among factorial effects, and for sex in particular. PMID:23840293
Effects of inter- and intra-observer variability on echocardiographic measurements in awake cats.
Chetboul, V; Concordet, D; Pouchelon, J L; Athanassiadis, N; Muller, C; Benigni, L; Munari, A C; Lefebvre, H P
2003-08-01
The objective of this study was to determine intra- and inter-observer variability of echocardiographic measurements in awake cats. Four observers with different levels of experience in echocardiography performed 96 echocardiographic examinations in four cats on four different days over a 3-week period. The examinations were randomized and blinded. The maximum within-day and between-day CV values were 17.4 and 18.5% for inter-ventricular septal thickness in diastole, 18.7 and 22.6% for left ventricular free-wall thickness in diastole, 9.8 and 14.9% for left ventricular end-diastolic diameter, 20.8 and 15.2% for left ventricular end-systolic diameter, and 21.2 and 18.4% for left ventricular shortening fraction. The maximum within-day CV values were most often associated with the least competent observer (i.e. the graduate student) and, the minimum CV values with the most competent observer (i.e. the associate professor in cardiology). A significant interaction between cat and observer was also evidenced. Thus, the most competent observer could not be replaced by any of the other observers.
Phytochrome-mediated synthesis of novel growth inhibitors, A-2α and β, and dwarfism in peas.
Noguchi, H; Hashimoto, T
1990-05-01
Variations in the content of A-2α and β, novel endogenous growth inhibitors, andcis,trans- andtrans, trans-xanthoxins were determined in 6- or 7-d-old, dark-grown seedlings of peas (Pisum sativum L. cvs. Progress No. 9, dwarf, and Alaska, tall) under various treatments with red light (R), and compared with R-induced growth inhibition. After transfer of the plants to continuous R the contents of the A-2s in cv. Progress increased after a 20-min lag, and reached plateaus after 12 h, whereas they remained almost unchanged in darkness. Both the rates of increase of the A-2s and the plateau levels were proportional to the logarithm of the irradiance applied. After a 10-min R pulse, the contents of both A-2α and β increased with the same rapidity to reach peaks after 6 h, and then gradually decreased to the initial levels after about 24 h. The effect of R was shown to be phytochrome-dependent, being nullified by far-red light. The level of neithercis,trans- nortrans,trans-xanthoxin showed such a close correlation with growth inhibition, although both xanthoxins increased as a result of phytochrome action. It is highly suggestive that the A-2s, rather than the xanthoxins, are responsible for phytochrome-dependent growth inhibition in cv. Progress. In cv. Alaska, in contrast, R-induced increase of the A-2s was rapid but slight, and could not explain the transient growth inhibition, which was found to be as large as that in cv. Progress shortly after the onset of R. The large content of the A-2s in cv. Progress in the steady state under continuous R, compared with that in cv. Alaska, may explain the dwarfism of cv. Progress.
Knee extension torque variability after exercise in ACL reconstructed knees.
Goetschius, John; Kuenze, Christopher M; Hart, Joseph M
2015-08-01
The purpose of this study was to compare knee extension torque variability in patients with ACL reconstructed knees before and after exercise. Thirty two patients with an ACL reconstructed knee (ACL-R group) and 32 healthy controls (control group) completed measures of maximal isometric knee extension torque (90° flexion) at baseline and following a 30-min exercise protocol (post-exercise). Exercise included 30-min of repeated cycles of inclined treadmill walking and hopping tasks. Dependent variables were the coefficient of variation (CV) and raw-change in CV (ΔCV): CV = (torque standard deviation/torque mean x 100), ΔCV = (post-exercise - baseline). There was a group-by-time interaction (p = 0.03) on CV. The ACL-R group demonstrated greater CV than the control group at baseline (ACL-R = 1.07 ± 0.55, control = 0.79 ± 0.42, p = 0.03) and post-exercise (ACL-R = 1.60 ± 0.91, control = 0.94 ± 0.41, p = 0.001). ΔCV was greater (p = 0.03) in the ACL-R group (0.52 ± 0.82) than control group (0.15 ± 0.46). CV significantly increased from baseline to post-exercise (p = 0.001) in the ACL-R group, while the control group did not (p = 0.06). The ACL-R group demonstrated greater knee extension torque variability than the control group. Exercise increased torque variability more in the ACL-R group than control group. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Prognostic Value of Adipokines in Predicting Cardiovascular Outcome: Explaining the Obesity Paradox.
Wolk, Robert; Bertolet, Marnie; Singh, Prachi; Brooks, Maria M; Pratley, Richard E; Frye, Robert L; Mooradian, Arshag D; Rutter, Martin K; Calvin, Andrew D; Chaitman, Bernard R; Somers, Virend K
2016-07-01
To evaluate the cardiovascular (CV) prognostic value of adipokines in a large prospective cohort of patients participating in the Bypass Angioplasty Revascularization Investigation 2 Diabetes trial. The effects of the adipokine levels at baseline and change from baseline on the composite outcome (CV death, myocardial infarction, and stroke) were analyzed using unadjusted and fully adjusted Cox models in 2330 patients with type 2 diabetes and coronary artery disease who had participated in the Bypass Angioplasty Revascularization Investigation 2 Diabetes trial (from January 1, 2001, through December 1, 2008). In a fully adjusted model, baseline leptin and change from baseline leptin were protective for CV events, whereas baseline adiponectin, baseline tumor necrosis factor α (TNF-α), change from baseline TNF-α, baseline C-reactive protein (CRP), and change from baseline CRP were harmful. The effect of baseline leptin on CV events depended on the body mass index (BMI), such that the hazard ratios (HRs) varied between 0.6 and 1.4 across the BMI quintiles (interaction P=.03). The same was true for baseline adiponectin (HR varied from 0.7 to 1.7; interaction P=.01), change from baseline monocyte chemoattractant protein-1 (HR varied from 0.8 to 1.8; interaction P=.03), change from baseline TNF-α (HR varied from 0.9 to 1.4; interaction P=.02), and change from baseline IL-6 (HR varied from 0.7 to 1.8; interaction P=.005). Adipokines are independent predictors of CV events in patients with type 2 diabetes and coronary artery disease. The association between the specific adipokines and CV outcome varies depending on BMI. This reflects the complex pathophysiology of CV disease in obesity and may help explain the "obesity paradox." clinicaltrials.gov Identifier: NCT00006305. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Elnaggar, Sameh Y.; Tervo, Richard; Mattar, Saba M.
2014-08-01
An electron paramagnetic resonance (EPR) spectrometer’s lambda efficiency parameter (Λ) is one of the most important parameters that govern its sensitivity. It is studied for an EPR probe consisting of a dielectric resonator (DR) in a cavity (CV). Expressions for Λ are derived in terms of the probe’s individual DR and CV components, Λ1 and Λ2 respectively. Two important cases are considered. In the first, a probe consisting of a CV is improved by incorporating a DR. The sensitivity enhancement depends on the relative rather than the absolute values of the individual components. This renders the analysis general. The optimal configuration occurs when the CV and DR modes are nearly degenerate. This configuration guarantees that the probe can be easily coupled to the microwave bridge while maintaining a large Λ. It is shown that for a lossy CV with a small quality factor Q2, one chooses a DR that has the highest filling factor, η1, regardless of its Λ1 and Q1. On the other hand, if the CV has a large Q2, the optimum DR is the one which has the highest Λ1. This is regardless of its η1 and relative dielectric constant, ɛr. When the quality factors of both the CV and DR are comparable, the lambda efficiency is reduced by a factor of √{2}. Thus the signal intensity for an unsaturated sample is cut in half. The second case is the design of an optimum shield to house a DR. Besides preventing radiation leakage, it is shown that for a high loss DR, the shield can actually boost Λ above the DR value. This can also be very helpful for relatively low efficiency dielectrics as well as lossy samples, such as polar liquids.
Skoglund, Per H; Arpegård, Johannes; Ostergren, Jan; Svensson, Per
2014-03-01
Patients with peripheral arterial disease (PAD) are at high risk for cardiovascular (CV) events. We have previously shown that ambulatory pulse pressure (APP) predicts CV events in PAD patients. The biomarkers amino-terminal pro-B-type natriuretic peptide (NT-proBNP), high-sensitivity C-reactive protein (hs-CRP), and cystatin C are related to a worse outcome in patients with CV disease, but their predictive values have not been studied in relation to APP. Blood samples and 24-hour measurements of ambulatory blood pressure were examined in 98 men referred for PAD evaluation during 1998-2001. Patients were followed for a median of 71 months. The outcome variable was CV events defined as either CV mortality or any hospitalization for myocardial infarction, stroke, or coronary revascularization. The predictive values of log(NT-proBNP), log(hs-CRP), and log(cystatin C) alone and together with APP were assessed by multivariable Cox regression. Area under the curve (AUC) and net reclassification improvement (NRI) were calculated compared with a model containing other significant risk factors. During follow-up, 36 patients had at least 1 CV event. APP, log(NT-proBNP), and log(hs-CRP) all predicted CV events in univariable analysis, whereas log(cystatin C) did not. In multivariable analysis log(NT-proBNP) (hazard ratio (HR) = 1.62; 95% confidence interval (CI) = 1.05-2.51) and log(hs-CRP) (HR = 1.63; 95% CI = 1.19-2.24) predicted events independently of 24-hour PP. The combination of log(NT-proBNP), log(hs-CRP), and average day PP improved risk discrimination (AUC = 0.833 vs. 0.736; P < 0.05) and NRI (37%; P < 0.01) when added to other significant risk factors. NT-proBNP and hs-CRP predict CV events independently of APP and the combination of hs-CRP, NT-proBNP, and day PP improves risk discrimination in PAD patients.
NASA Astrophysics Data System (ADS)
Liu, Kailin; Xu, Shiji; Zhang, Minghuan; Kou, Yahong; Zhou, Xiaomao; Luo, Kun; Hu, Lifeng; Liu, Xiangying; Liu, Min; Bai, Lianyang
2016-12-01
The toxicity of ionizable organic compounds to organisms depends on the pH, which therefore affects risk assessments of these compounds. However, there is not a direct chemical method to predict the toxicity of ionizable organic compounds. To determine whether hollow-fiber liquid-phase microextraction (HF-LPME) is applicable for this purpose, a three-phase HF-LPME was used to measure sulfadiazine and estimate its toxicity to Daphnia magna in solutions of different pH. The result indicated that the sulfadiazine concentrations measured by HF-LPME decreased with increasing pH, which is consistent with the decreased toxicity. The concentration immobilize 50% of the daphnids (EC50) in 48 h calculated from nominal concentrations increased from 11.93 to 273.5 mg L-1 as the pH increased from 6.0 to 8.5, and the coefficient of variation (CV) of the EC50 values reached 104.6%. When calculated from the concentrations measured by HF-LPME (pH 12 acceptor phase), the EC50 ranged from 223.4 to 394.6 mg L-1, and the CV decreased to 27.60%, suggesting that the concentrations measured by HF-LPME can be used to estimate the toxicity of sulfadiazine irrespective of the solution pH.
NASA Astrophysics Data System (ADS)
Reddy, P. R. Sekhar; Janardhanam, V.; Jyothi, I.; Harsha, Cirandur Sri; Reddy, V. Rajagopal; Lee, Sung-Nam; Won, Jonghan; Choi, Chel-Jong
2018-02-01
Effects of the thickness of copper phthalocyanine (CuPc) film (2, 5, 10, 15, 20, 30 and 40 nm) on the surface morphology, optical and electrical properties of Au/CuPc/n-Si heterojunction have been investigated. The optical band gap of CuPc film was increased with increase in the thickness of the CuPc film. The electrical properties of the Au/n-Si Schottky junction and Au/CuPc/n-Si heterojunctions were characterized by current-voltage ( I-V) and capacitance-voltage ( C-V) measurements. The barrier height, ideality factor and series resistance were estimated based on the I-V, Cheung's and Norde's methods. The barrier heights increased with increasing CuPc interlayer thickness up to 15 nm and remained constant for thickness above 20 nm, associated with the incapability of the generated carriers to reach the interface. The discrepancy in the barrier heights obtained from I-V and C-V measurements indicates the presence of barrier inhomogeneity at the interface as evidenced by higher ideality factor values. It can be concluded that the electrical properties of Au/n-Si Schottky junction can be significantly altered with the variation of CuPc thickness as interlayer.
NASA Astrophysics Data System (ADS)
Mathavan, Senthan; Kumar, Akash; Kamal, Khurram; Nieminen, Michael; Shah, Hitesh; Rahman, Mujib
2016-09-01
Thousands of pavement images are collected by road authorities daily for condition monitoring surveys. These images typically have intensity variations and texture nonuniformities that make their segmentation challenging. The automated segmentation of such pavement images is crucial for accurate, thorough, and expedited health monitoring of roads. In the pavement monitoring area, well-known texture descriptors, such as gray-level co-occurrence matrices and local binary patterns, are often used for surface segmentation and identification. These, despite being the established methods for texture discrimination, are inherently slow. This work evaluates Laws texture energy measures as a viable alternative for pavement images for the first time. k-means clustering is used to partition the feature space, limiting the human subjectivity in the process. Data classification, hence image segmentation, is performed by the k-nearest neighbor method. Laws texture energy masks are shown to perform well with resulting accuracy and precision values of more than 80%. The implementations of the algorithm, in both MATLAB® and OpenCV/C++, are extensively compared against the state of the art for execution speed, clearly showing the advantages of the proposed method. Furthermore, the OpenCV-based segmentation shows a 100% increase in processing speed when compared to the fastest algorithm available in literature.
Cirnigliaro, Christopher M.; Lesser, Marvin; Moyer, Jeremy; Kirshblum, Steven C.; Bauman, William A.; Spungen, Ann M.
2012-01-01
Background The impulse oscillation system (IOS) offers significant value in the assessment of airway dynamics in persons with spinal cord injury (SCI) because of minimal patient effort but measurement reproducibility in SCI is unknown. Objective To evaluate between-day reproducibility and the effect of posture on airway resistance [respiratory resistances at 5 Hz (R5) and 20 Hz (R20)] in subjects with tetraplegia, paraplegia and able-bodied controls. Methods Ten subjects with tetraplegia, 10 subjects with paraplegia and 11 able-bodied individuals were evaluated using IOS. Three 30 second trials were obtained in each while in the seated and supine position on Day 1, and repeated on Day 2. Results The within-day coefficient of variation (CV%) for R5 and R20 were comparable in the 3 study groups in the seated and supine positions. Compared to controls, the between-day CV% for the combined data was higher in subjects with tetraplegia and paraplegia for R5 seated, and was higher in subjects with tetraplegia for R5 supine. Conclusions IOS has applicability to the study of within-day respiratory resistance in SCI. However, performing longer-term studies in subjects with tetraplegia and paraplegia may be problematic because of the greater variability for R5 when compared to able-bodied individuals. PMID:22330188
The Effect of Herbaceous Legume of Feed in In-Vitro Digestibility
NASA Astrophysics Data System (ADS)
Ratnawaty, S.; Hartutik; Chuzaemi, S.
2018-02-01
This study was carried out to evaluate in-vitro digestibility of herbal legumesin feed. The materials used in this study were three types of herbal legumes namely Clitoria ternatea Q5455 (CT Q5455), Clitoria ternatea cv. Milgarra (CT cv Milgarra) and Stylosanthes seabrana (S. seabrana), The treatments were P0 = 100% Grass; P1 = 50% Grass+ 50% CT Q5455, P2 = 50% Grass + 50% CT cv. Milgarra, P3 = 50% Grass + 50% S. seabrana. The result showed that the treatments had a significant effect (P <0.05). The highest dry matter (DM) digestibilitywas in P1 (60.35%) and P3 (60.22%). The DM digestibility of the highest raw materials was in CT cv. Milgarra (73.49%) and the lowest one was in S. seabrana (63.90%). The treatments had a very significant effect (P <0.01) on the organic matter (OM) Digestibility. The highest OM digestibility wasin P1 (63.04%) and P3 (61.89%). The highest value of OM digestibility of raw materials was in CT cv. Milgarra (73.90%) and the lowest one was in S. seabrana (63.85%). The treatmentshad a significant effect (P <0.05) on the crude protein (CP) digestibility. The average CP digestibility of feed was at the same value in all treatments but in CT Q5455 (67.25%). The treatmentshad a significant effect (P <0.05) on the total digestible nutrients (TDN). The highest TDN was in P1 (66.19%) and the lowest one was in P0 (51.38%). Average TDN of the highest raw material was in CT cv. Milgarra (77.59%) and the lowest was in S. seabrana (67.04%).
Lienkaemper, James J.; Baldwin, John N.; Turner, Robert; Sickler, Robert R.; Brown, Johnathan
2013-01-01
We document evidence for surface-rupturing earthquakes (events) at two trench sites on the southern Green Valley fault, California (SGVF). The 75-80-km long dextral SGVF creeps ~1-4 mm/yr. We identify stratigraphic horizons disrupted by upward-flowering shears and in-filled fissures unlikely to have formed from creep alone. The Mason Rd site exhibits four events from ~1013 CE to the Present. The Lopes Ranch site (LR, 12 km to the south) exhibits three events from 18 BCE to Present including the most recent event (MRE), 1610 ±52 yr CE (1σ) and a two-event interval (18 BCE-238 CE) isolated by a millennium of low deposition. Using Oxcal to model the timing of the 4-event earthquake sequence from radiocarbon data and the LR MRE yields a mean recurrence interval (RI or μ) of 199 ±82 yr (1σ) and ±35 yr (standard error of the mean), the first based on geologic data. The time since the most recent earthquake (open window since MRE) is 402 yr ±52 yr, well past μ~200 yr. The shape of the probability density function (pdf) of the average RI from Oxcal resembles a Brownian Passage Time (BPT) pdf (i.e., rather than normal) that permits rarer longer ruptures potentially involving the Berryessa and Hunting Creek sections of the northernmost GVF. The model coefficient of variation (cv, σ/μ) is 0.41, but a larger value (cv ~0.6) fits better when using BPT. A BPT pdf with μ of 250 yr and cv of 0.6 yields 30-yr rupture probabilities of 20-25% versus a Poisson probability of 11-17%.
NASA Astrophysics Data System (ADS)
Li, Zhong Qiao; Wu, Ying; Liu, Su Mei; Du, Jin Zhou; Zhang, Jing
2016-02-01
The East China Sea (ECS) is a large river dominated marginal sea and receives massive volumes of terrestrial material from the Changjiang (Yangtze River). As the ECS preserves a record of terrestrial material derived from the Changjiang Basin, cores collected from this region can be used to reconstruct paleoclimate change and human disturbance in the watershed. A core (P4) was collected from the ECS shelf break and analyzed for bulk parameters (organic carbon (OC), total nitrogen (TN), and stable carbon isotopes (δ13C)), lignin phenols, and 3,5-dihydroxy benzoic acid (DHBA). The depth profiles of these parameters indicate stable and consistent marine production. The lignin source indices, cinnamyl phenols vs. vanillyl phenols (C/V) and syringyl phenols vs. vanillyl phenols (S/V), were in agreement with previously reported results from ECS surface sediments, but differed markedly from Bohai Sea surface sediments. The ratio of acid to aldehyde in vanillyl phenols ((Ad/Al)v) indicated the terrestrial OC in this core was refractory. At the same time, the variation in lignin phenols is positively correlated with the strength of the Indian Summer Monsoon (ISM) over the last 800 years (p<0.001). This is because most sediment is delivered from the upper reaches of the Changjiang Basin, where the ISM is the key control on precipitation. Two extreme drought events, around 1580 A.D. and 1770 A.D. were also identified in the core based on the extremely low C/V, S/V, lignin phenol vegetation index (LPVI), and DHBA values. Furthermore, the significant shift in C/V and S/V since 1880 A.D. is probably a reflection of increased human activity in the upper Changjiang Basin over this period.
Reliability and validity of the combined heart rate and movement sensor Actiheart.
Brage, S; Brage, N; Franks, P W; Ekelund, U; Wareham, N J
2005-04-01
Accurate quantification of physical activity energy expenditure is a key part of the effort to understand disorders of energy metabolism. The Actiheart, a combined heart rate (HR) and movement sensor, is designed to assess physical activity in populations. To examine aspects of Actiheart reliability and validity in mechanical settings and during walking and running. In eight Actiheart units, technical reliability (coefficients of variation, CV) and validity for movement were assessed with sinusoid accelerations (0.1-20 m/s(2)) and for HR by simulated R-wave impulses (25-250 bpm). Agreement between Actiheart and ECG was determined during rest and treadmill locomotion (3.2-12.1 km/h). Walking and running intensity (in J/min/kg) was assessed with indirect calorimetry in 11 men and nine women (26-50 y, 20-29 kg/m(2)) and modelled from movement, HR, and movement + HR by multiple linear regression, adjusting for sex. Median intrainstrument CV was 0.5 and 0.03% for movement and HR, respectively. Corresponding interinstrument CV values were 5.7 and 0.03% with some evidence of heteroscedasticity for movement. The linear relationship between movement and acceleration was strong (R(2) = 0.99, P < 0.001). Simulated R-waves were detected within 1 bpm from 30 to 250 bpm. The 95% limits of agreement between Actiheart and ECG were -4.2 to 4.3 bpm. Correlations with intensity were generally high (R(2) > 0.84, P < 0.001) but significantly highest when combining HR and movement (SEE < 1 MET). The Actiheart is technically reliable and valid. Walking and running intensity may be estimated accurately but further studies are needed to assess validity in other activities and during free-living. The study received financial support from the Wellcome Trust and SB was supported by a scholarship from Unilever, UK.
READ, PAUL; OLIVER, JON L.; DE STE CROIX, MARK B.A.; MYER, GREGORY D.; LLOYD, RHODRI S.
2016-01-01
Deficits in neuromuscular control during movement patterns such as landing are suggested pathomechanics that underlie sport-related injury. A common mode of assessment is measurement of landing forces during jumping tasks; however, these measures have been used less frequently in male youth soccer players and reliability data is sparse. The aim of this study was to examine the reliability of a field-based neuromuscular control screening battery using force plate diagnostics in this cohort. Twenty six pre-peak height velocity (PHV) and twenty five post-PHV elite male youth soccer players completed a drop vertical jump (DVJ), single leg 75% horizontal hop and stick (75%HOP) and single leg countermovement jump (SLCMJ). Measures of peak landing vertical ground reaction force (pVGRF), time to stabilisation (TTS), time to pVGRF, and pVGRF asymmetry were recorded. A test, re-test design was used and reliability statistics included: change in mean, intraclass correlation coefficient (ICC) and coefficient of variation (CV). No significant differences in mean score were reported for any of the assessed variables between test sessions. In both groups, pVGRF and asymmetry during the 75%HOP and SLCMJ demonstrated largely acceptable reliability (CV ≤ 10%). Greater variability was evident in DVJ pVGRF and all other assessed variables, across the three protocols (CV range = 13.8 – 49.7%). ICC values ranged from small to large and were generally higher in the post-PHV players. The results of this study suggest that pVGRF and asymmetry can be reliably assessed using a 75%HOP and SLCMJ in this cohort. These measures could be utilized to support a screening battery for elite male youth soccer players and for test re-test comparison. PMID:27075641
Measurement of EMG activity with textile electrodes embedded into clothing.
Finni, T; Hu, M; Kettunen, P; Vilavuo, T; Cheng, S
2007-11-01
Novel textile electrodes that can be embedded into sports clothing to measure averaged rectified electromyography (EMG) have been developed for easy use in field tests and in clinical settings. The purpose of this study was to evaluate the validity, reliability and feasibility of this new product to measure averaged rectified EMG. The validity was tested by comparing the signals from bipolar textile electrodes (42 cm(2)) and traditional bipolar surface electrodes (1.32 cm(2)) during bilateral isometric knee extension exercise with two electrode locations (A: both electrodes located in the same place, B: traditional electrodes placed on the individual muscles according to SENIAM, n=10 persons for each). Within-session repeatability (the coefficient of variation CV%, n=10) was calculated from five repetitions of 60% maximum voluntary contraction (MVC). The day-to-day repeatability (n=8) was assessed by measuring three different isometric force levels on five consecutive days. The feasibility of the textile electrodes in field conditions was assessed during a maximal treadmill test (n=28). Bland-Altman plots showed a good agreement within 2SD between the textile and traditional electrodes, demonstrating that the textile electrodes provide similar information on the EMG signal amplitude to the traditional electrodes. The within-session CV ranged from 13% to 21% in both the textile and traditional electrodes. The day-to-day CV was smaller, ranging from 4% to 11% for the textile electrodes. A similar relationship (r(2)=0.5) was found between muscle strength and the EMG of traditional and textile electrodes. The feasibility study showed that the textile electrode technique can potentially make EMG measurements very easy in field conditions. This study indicates that textile electrodes embedded into shorts is a valid and feasible method for assessing the average rectified value of EMG.
Virgincar, Rohan S.; Cleveland, Zackary I.; Kaushik, S. Sivaram; Freeman, Matthew S.; Nouls, John; Cofer, Gary P.; Martinez-Jimenez, Santiago; He, Mu; Kraft, Monica; Wolber, Jan; McAdams, H. Page; Driehuys, Bastiaan
2013-01-01
In this study, hyperpolarized (HP) 129Xe MR ventilation and 1H anatomical images were obtained from 3 subject groups: young healthy volunteers (HV), subjects with chronic obstructive pulmonary disease (COPD), and age-matched control subjects (AMC). Ventilation images were quantified by 2 methods: an expert reader-based ventilation defect score percentage (VDS%) and a semi-automatic segmentation-based ventilation defect percentage (VDP). Reader-based values were assigned by two experienced radiologists and resolved by consensus. In the semi-automatic analysis, 1H anatomical images and 129Xe ventilation images were both segmented following registration, to obtain the thoracic cavity volume (TCV) and ventilated volume (VV), respectively, which were then expressed as a ratio to obtain the VDP. Ventilation images were also characterized by generating signal intensity histograms from voxels within the TCV, and heterogeneity was analyzed using the coefficient of variation (CV). The reader-based VDS% correlated strongly with the semi-automatically generated VDP (r = 0.97, p < 0.0001), and with CV (r = 0.82, p < 0.0001). Both 129Xe ventilation defect scoring metrics readily separated the 3 groups from one another and correlated significantly with FEV1 (VDS%: r = -0.78, p = 0.0002; VDP: r = -0.79, p = 0.0003; CV: r = -0.66, p = 0.0059) and other pulmonary function tests. In the healthy subject groups (HV and AMC), the prevalence of ventilation defects also increased with age (VDS%: r = 0.61, p = 0.0002; VDP: r = 0.63, p = 0.0002). Moreover, ventilation histograms and their associated CVs distinguished between COPD subjects with similar ventilation defect scores but visibly different ventilation patterns. PMID:23065808
The relationship between CK and CV chondrites
NASA Astrophysics Data System (ADS)
Greenwood, R. C.; Franchi, I. A.; Kearsley, A. T.; Alard, O.
2010-03-01
CK chondrites are highly oxidized meteorites containing abundant magnetite and trace amounts of Fe,Ni metal. Although the group is predominately composed of equilibrated meteorites (types 4-6), in recent years a significant number of new samples have been classified as being either CK3 or CK3-anomalous. These unequilibrated CKs often display a close affinity with members of the CV oxidized subgroup. CKs and CVs (oxidized subgroup) may therefore form a continuum and by implication could be derived from a single common parent body. To investigate the relationship between these two groups a detailed study of the oxygen isotope composition, opaque mineralogy and major and trace element geochemistry of a suite of CV and CK chondrites has been undertaken. The results of oxygen isotope analysis confirm the close affinity between CV and CK chondrites, while excluding the possibility of a linkage between the CO and CK groups. Magnetites in both CV and CK chondrites show significant compositional similarities, but high Ti contents are a diagnostic feature of the latter group. The results of major and trace element analysis demonstrate that both CV and CK chondrites show overlapping variation. Supporting evidence for a single common source for both groups comes from their similar cosmic-ray exposure age distributions. Recent reflectance spectral analysis is consistent with both the CVs and CKs being derived from Eos family asteroids, which are believed to have formed by the catastrophic disruption of a single large asteroid. Thus, a range of evidence appears to be consistent with CV and CK chondrites representing samples from a single thermally stratified parent body. In view of the close similarity between CV and CK chondrites some modification of the present classification scheme may be warranted, possibly involving integration of the two groups. One means of achieving this would be to reassigned CK chondrites to a subgroup of the oxidized CVs. It is recognized that a full evaluation of this proposal may require further study of the still poorly understood CK3 chondrites.
Wei, Kai-Fa; Chen, Juan; Chen, Yan-Feng; Wu, Ling-Juan; Xie, Dao-Xin
2012-01-01
The WRKY transcription factors function in plant growth and development, and response to the biotic and abiotic stresses. Although many studies have focused on the functional identification of the WRKY transcription factors, much less is known about molecular phylogenetic and global expression analysis of the complete WRKY family in maize. In this study, we identified 136 WRKY proteins coded by 119 genes in the B73 inbred line from the complete genome and named them in an orderly manner. Then, a comprehensive phylogenetic analysis of five species was performed to explore the origin and evolutionary patterns of these WRKY genes, and the result showed that gene duplication is the major driving force for the origin of new groups and subgroups and functional divergence during evolution. Chromosomal location analysis of maize WRKY genes indicated that 20 gene clusters are distributed unevenly in the genome. Microarray-based expression analysis has revealed that 131 WRKY transcripts encoded by 116 genes may participate in the regulation of maize growth and development. Among them, 102 transcripts are stably expressed with a coefficient of variation (CV) value of <15%. The remaining 29 transcripts produced by 25 WRKY genes with the CV value of >15% are further analysed to discover new organ- or tissue-specific genes. In addition, microarray analyses of transcriptional responses to drought stress and fungal infection showed that maize WRKY proteins are involved in stress responses. All these results contribute to a deep probing into the roles of WRKY transcription factors in maize growth and development and stress tolerance. PMID:22279089
Wei, Kai-Fa; Chen, Juan; Chen, Yan-Feng; Wu, Ling-Juan; Xie, Dao-Xin
2012-04-01
The WRKY transcription factors function in plant growth and development, and response to the biotic and abiotic stresses. Although many studies have focused on the functional identification of the WRKY transcription factors, much less is known about molecular phylogenetic and global expression analysis of the complete WRKY family in maize. In this study, we identified 136 WRKY proteins coded by 119 genes in the B73 inbred line from the complete genome and named them in an orderly manner. Then, a comprehensive phylogenetic analysis of five species was performed to explore the origin and evolutionary patterns of these WRKY genes, and the result showed that gene duplication is the major driving force for the origin of new groups and subgroups and functional divergence during evolution. Chromosomal location analysis of maize WRKY genes indicated that 20 gene clusters are distributed unevenly in the genome. Microarray-based expression analysis has revealed that 131 WRKY transcripts encoded by 116 genes may participate in the regulation of maize growth and development. Among them, 102 transcripts are stably expressed with a coefficient of variation (CV) value of <15%. The remaining 29 transcripts produced by 25 WRKY genes with the CV value of >15% are further analysed to discover new organ- or tissue-specific genes. In addition, microarray analyses of transcriptional responses to drought stress and fungal infection showed that maize WRKY proteins are involved in stress responses. All these results contribute to a deep probing into the roles of WRKY transcription factors in maize growth and development and stress tolerance.
Quantity quotient reporting. A proposal for a standardized presentation of laboratory results.
Haeckel, Rainer; Wosniok, Werner
2009-01-01
Laboratory results are reported in different units (despite international recommendations for SI units) together with different reference limits, of which several exist for many quantities. It is proposed to adopt the concept of the intelligence quotient and to report quantitative results as a quantity quotient (QQ) in laboratory medicine. This quotient is essentially the difference (measured result minus mean or mode value of the reference interval) divided by the observed biological variation CV(o). Thus, all quantities are reported in the same unit system with the same reference limits (for convenience shifted to e.g., 80-120). The critical difference can also be included in this standardization concept. In this way the information of reference intervals and the original result are integrated into one combined value, which has the same format for all quantities suited for quotient reporting (QR). The proposal of QR does not interfere with neither the current concepts of traceability, SI units or method standardization. This proposal represents a further step towards harmonization of reporting. It provides simple values which can be interpreted easily by physicians and their patients.
Ayoubi, Shamsollah; Mokhtari, Javad; Mosaddeghi, Mohammad Reza; Zeraatpisheh, Mojtaba
2018-03-06
The most important properties affecting the soil loss and runoff were investigated, and the effects of land use on the soil properties, together with the erodibility indices in a semiarid zone, central Iran, were evaluated. The locations of 100 positions were acquired by cLHS and 0-5-cm surface soil layer samples were used for laboratory analyses from the Borujen Region, Chaharmahal-Va-Bakhtiari Province, central Iran. To measure in situ runoff and soil erodibility of three different land uses comprising dryland, irrigated farming, and rangeland, a portable rainfall simulator was used. The results showed that the high variations (coefficient of variation, CV) were obtained for electrical conductivity (EC), mean weight diameter (MWD), soil organic carbon (SOC), and soil erodibility indices including runoff volume, soil loss, and sediment concentration (CV ~ 43.6-77.4%). Soil erodibility indices showed positive and significant correlations with bulk density and negative correlations with SOC, MWD, clay content, and soil shear strength in the area under investigation. The values of runoff in the dryland, irrigated farming, and rangeland were found 1.5, 28.9, and 58.7 cm 3 ; soil loss in the dryland, irrigated farming, and rangeland were observed 0.25, 2.96, and 76.8 g; and the amount of sediment concentration in the dryland, irrigated farming, and rangeland were found 0.01, 0.11, and 0.15 g cm -3 . It is suggested that further investigations should be carried out on soil erodibility and the potential of sediment yield in various land uses with varying topography and soil properties in semiarid regions of Iran facing the high risk of soil loss.
Armstrong, Anderson C.; Ricketts, Erin P.; Cox, Christopher; Adler, Paul; Arynchyn, Alexander; Liu, Kiang; Stengel, Ellen; RDCS; Sidney, Stephen; Lewis, Cora E.; Schreiner, Pamela J.; Shikany, James M.; Keck, Kimberly; Merlo, Jamie; Gidding, Samuel S.; Lima, João A. C.
2014-01-01
Introduction Few large studies describe quality control procedures and reproducibility findings in cardiovascular ultra-sound, particularly in novel techniques such as Speckle Tracking (STE). We evaluate the echocardiography assessment performance in the CARDIA study Y25 examination (2010-2011) and report findings from a quality control and reproducibility program conducted to assess Field Center image acquisition and Reading Center (RC) accuracy. Methods The CARDIA Y25 examination had 3,475 echocardiograms performed in 4 US Field Centers and analyzed in a Reading Center, assessing standard echocardiography (LA dimension, aortic root, LV mass, LV end-diastolic volume [LVEDV], ejection fraction [LVEF]), and STE (2- and 4-chamber longitudinal, circumferential, and radial strains). Reproducibility was assessed using intra-class correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman plots. Results For standard echocardiography reproducibility, LV mass and LVEDV consistently had CV above 10% and aortic root below 6%. Intra-sonographer aortic root and LV mass had the most robust values of ICC in standard echocardiography. For STE, the number of properly tracking segments was above 80% in short-axis and 4-chamber and 58% in 2-chamber. Longitudinal strain parameters were the most robust and radial strain showed the highest variation. Comparing Field Centers with Echo RC STE readings, mean differences ranged from 0.4% to 4.1% and ICC from 0.37 to 0.66, with robust results for longitudinal strains. Conclusion Echocardiography image acquisition and reading processes in the CARDIA study were highly reproducible, including robust results for STE analysis. Consistent quality control may increase the reliability of echocardiography measurements in large cohort studies. PMID:25382818
Armstrong, Anderson C; Ricketts, Erin P; Cox, Christopher; Adler, Paul; Arynchyn, Alexander; Liu, Kiang; Stengel, Ellen; Sidney, Stephen; Lewis, Cora E; Schreiner, Pamela J; Shikany, James M; Keck, Kimberly; Merlo, Jamie; Gidding, Samuel S; Lima, João A C
2015-08-01
Few large studies describe quality control procedures and reproducibility findings in cardiovascular ultrasound, particularly in novel techniques such as speckle tracking echocardiography (STE). We evaluate the echocardiography assessment performance in the Coronary Artery Risk Development in Young Adults (CARDIA) study Year 25 (Y25) examination (2010-2011) and report findings from a quality control and reproducibility program conducted to assess Field Center image acquisition and reading center (RC) accuracy. The CARDIA Y25 examination had 3475 echocardiograms performed in 4 US Field Centers and analyzed in a RC, assessing standard echocardiography (LA dimension, aortic root, LV mass, LV end-diastolic volume [LVEDV], ejection fraction [LVEF]), and STE (two- and four-chamber longitudinal, circumferential, and radial strains). Reproducibility was assessed using intraclass correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman plots. For standard echocardiography reproducibility, LV mass and LVEDV consistently had CV above 10% and aortic root below 6%. Intra-sonographer aortic root and LV mass had the most robust values of ICC in standard echocardiography. For STE, the number of properly tracking segments was above 80% in short-axis and four-chamber and 58% in two-chamber views. Longitudinal strain parameters were the most robust and radial strain showed the highest variation. Comparing Field Centers with echocardiography RC STE readings, mean differences ranged from 0.4% to 4.1% and ICC from 0.37 to 0.66, with robust results for longitudinal strains. Echocardiography image acquisition and reading processes in the CARDIA study were highly reproducible, including robust results for STE analysis. Consistent quality control may increase the reliability of echocardiography measurements in large cohort studies. © 2014, Wiley Periodicals, Inc.
Rodbard, David
2012-10-01
We describe a new approach to estimate the risks of hypo- and hyperglycemia based on the mean and SD of the glucose distribution using optional transformations of the glucose scale to achieve a more nearly symmetrical and Gaussian distribution, if necessary. We examine the correlation of risks of hypo- and hyperglycemia calculated using different glucose thresholds and the relationships of these risks to the mean glucose, SD, and percentage coefficient of variation (%CV). Using representative continuous glucose monitoring datasets, one can predict the risk of glucose values above or below any arbitrary threshold if the glucose distribution is Gaussian or can be transformed to be Gaussian. Symmetry and gaussianness can be tested objectively and used to optimize the transformation. The method performs well with excellent correlation of predicted and observed risks of hypo- or hyperglycemia for individual subjects by time of day or for a specified range of dates. One can compare observed and calculated risks of hypo- and hyperglycemia for a series of thresholds considering their uncertainties. Thresholds such as 80 mg/dL can be used as surrogates for thresholds such as 50 mg/dL. We observe a high correlation of risk of hypoglycemia with %CV and illustrate the theoretical basis for that relationship. One can estimate the historical risks of hypo- and hyperglycemia by time of day, date, day of the week, or range of dates, using any specified thresholds. Risks of hypoglycemia with one threshold (e.g., 80 mg/dL) can be used as an effective surrogate marker for hypoglycemia at other thresholds (e.g., 50 mg/dL). These estimates of risk can be useful in research studies and in the clinical care of patients with diabetes.
Baume, Norbert; Geyer, Hans; Vouillamoz, Marc; Grisdale, Richard; Earl, Mike; Aguilera, Rodrigo; Cowan, David A; Ericsson, Magnus; Gmeiner, Günter; Kwiatkowska, Dorota; Kioukia-Fougia, Nassia; Molina, Adeline; Ruivo, João; Segura, Jordi; Van Eenoo, Peter; Jan, Nicolas; Robinson, Neil; Saugy, Martial
2016-07-01
Testosterone and related compounds are the most recurrent doping substances. The steroid profile, consisting of the quantification of testosterone and its metabolites, has been described as the most significant biomarker to detect doping with pseudo-endogenous anabolic steroids. The steroidal module of the Athlete Biological Passport (ABP) was launched by the World Anti-Doping Agency (WADA) in 2014. To assess the value of introducing the module to its anti-doping programme, the Union of European Football Associations (UEFA) decided to analyze retrospectively the steroid profile data of 4195 urine samples, collected from 879 male football players and analyzed in 12 WADA-accredited laboratories between 2008 and mid-2013. This study focused on the evaluation of T/E ratios. The coefficient of variation (CV) and the adaptive model were the two statistical models used to study the longitudinal follow-up. A CV of 46% was determined to be the maximal natural intra-individual variation of the T/E when the sequence consisted of single data points analyzed in different laboratories. The adaptive model showed some profiles with an atypical T/E sequence and also enabled an estimate of the prevalence of external factors impacting the T/E sequences. Despite the limitations of this retrospective study, it clearly showed that the longitudinal and individual follow-up of the T/E biomarker of the players is a good tool for target testing in football. UEFA has therefore decided to implement the steroidal module of the ABP from the start of the next European football season in September 2015. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Yamada, Hiroya; Takano, Toru; Kihara, Minoru; Hirokawa, Mitsuyoshi; Yoshida, Hiroshi; Watanabe, Mikio; Iwatani, Yoshinori; Hidaka, Yoh; Miyauchi, Akira
2012-01-01
Measurement of gene expression levels in thyroid tumor cells in aspirates was difficult because it is interfered with peripheral blood cells or infiltrating lymphocytes. In this study, we established a novel method to separate thyroid tumor cells from blood cells efficiently with mesh filtration. The expression level of trefoil factor 3 (TFF3) mRNA was estimated using LGALS3 mRNA as an internal control (T/G ratio) in 148 preoperative thyroid aspirates. Intra-assay coefficients of variation (CV) of T/G ratio for high, moderate, and low samples were 6.5%, 2.5%, and 9.7%, respectively, and inter-assay CV for high, moderate, and low samples were 27.7%, 21.9%, and 38.2%, respectively. Nondiagnostic samples in terms of T/G ratio and cytology were 12.2% and 16.9%, respectively. We observed no interference with the data by contaminating blood cells. Among these patients, 12 patients received more than two repeated aspirations. We did not observe a marked day-to-day variation except in two cases. All 13 preoperative aspirates diagnosed as malignant by cytology showed an extremely low T/G ratio, whereas 93 aspirates diagnosed as benign by cytology showed extremely varied T/G ratios and 21.5% of them showed a T/G ratio below the cut-off value. Eleven cases underwent surgery. All nodules showing a low T/G ratio were diagnosed as papillary carcinoma by pathological diagnosis. However, one nodule diagnosed as follicular adenoma after surgery showed a high T/G ratio. Our present method may be a promising preoperative test for measuring mRNAs in thyroid aspirates.
NASA Astrophysics Data System (ADS)
Opanchuk, B.; Arnaud, L.; Reid, M. D.
2014-06-01
We demonstrate the principle of one-sided device-independent continuous-variable (CV) quantum information. In situations of no trust, we show by enactment how the use of standard CV entanglement criteria can mislead Charlie into thinking that Alice and Bob share entanglement, when the data are actually generated classically using a local-hidden-variable theory based on the Wigner function. We distinguish between criteria that demonstrate CV entanglement, and criteria that demonstrate the CV Einstein-Podolsky-Rosen (EPR) steering paradox. We show that the latter, but not the former, are necessarily one-sided device-independent entanglement witnesses, and can be used by Charlie to signify genuine EPR entanglement, if he trusts only Alice. A monogamy result for the EPR steering paradox confirms the security of the shared amplitude values in that case.
Nibali, Maria L; Tombleson, Tom; Brady, Philip H; Wagner, Phillip
2015-10-01
Understanding typical variation of vertical jump (VJ) performance and confounding sources of its typical variability (i.e., familiarization and competitive level) is pertinent in the routine monitoring of athletes. We evaluated the presence of systematic error (learning effect) and nonuniformity of error (heteroscedasticity) across VJ performances of athletes that differ in competitive level and quantified the reliability of VJ kinetic and kinematic variables relative to the smallest worthwhile change (SWC). One hundred thirteen high school athletes, 30 college athletes, and 35 professional athletes completed repeat VJ trials. Average eccentric rate of force development (RFD), average concentric (CON) force, CON impulse, and jump height measurements were obtained from vertical ground reaction force (VGRF) data. Systematic error was assessed by evaluating changes in the mean of repeat trials. Heteroscedasticity was evaluated by plotting the difference score (trial 2 - trial 1) against the mean of the trials. Variability of jump variables was calculated as the typical error (TE) and coefficient of variation (%CV). No substantial systematic error (effect size range: -0.07 to 0.11) or heteroscedasticity was present for any of the VJ variables. Vertical jump can be performed without the need for familiarization trials, and the variability can be conveyed as either the raw TE or the %CV. Assessment of VGRF variables is an effective and reliable means of assessing VJ performance. Average CON force and CON impulse are highly reliable (%CV: 2.7% ×/÷ 1.10), although jump height was the only variable to display a %CV ≤SWC. Eccentric RFD is highly variable yet should not be discounted from VJ assessments on this factor alone because it may be sensitive to changes in response to training or fatigue that exceed the TE.
Fritz, Ann‐Kristina; Amrein, Irmgard
2017-01-01
Although most nervous system diseases affect women and men differentially, most behavioral studies using mouse models do not include subjects of both sexes. Many researchers worry that data of female mice may be unreliable due to the estrous cycle. Here, we retrospectively evaluated sex effects on coefficient of variation (CV) in 5,311 mice which had performed the same place navigation protocol in the water‐maze and in 4,554 mice tested in the same open field arena. Confidence intervals for Cohen's d as measure of effect size were computed and tested for equivalence with 0.2 as equivalence margin. Despite the large sample size, only few behavioral parameters showed a significant sex effect on CV. Confidence intervals of effect size indicated that CV was either equivalent or showed a small sex difference at most, accounting for less than 2% of total group to group variation of CV. While female mice were potentially slightly more variable in water‐maze acquisition and in the open field, males tended to perform less reliably in the water‐maze probe trial. In addition to evaluating variability, we also directly compared mean performance of female and male mice and found them to be equivalent in both water‐maze place navigation and open field exploration. Our data confirm and extend other large scale studies in demonstrating that including female mice in experiments does not cause a relevant increase of data variability. Our results make a strong case for including mice of both sexes whenever open field or water‐maze are used in preclinical research. PMID:28654717
Fritz, Ann-Kristina; Amrein, Irmgard; Wolfer, David P
2017-09-01
Although most nervous system diseases affect women and men differentially, most behavioral studies using mouse models do not include subjects of both sexes. Many researchers worry that data of female mice may be unreliable due to the estrous cycle. Here, we retrospectively evaluated sex effects on coefficient of variation (CV) in 5,311 mice which had performed the same place navigation protocol in the water-maze and in 4,554 mice tested in the same open field arena. Confidence intervals for Cohen's d as measure of effect size were computed and tested for equivalence with 0.2 as equivalence margin. Despite the large sample size, only few behavioral parameters showed a significant sex effect on CV. Confidence intervals of effect size indicated that CV was either equivalent or showed a small sex difference at most, accounting for less than 2% of total group to group variation of CV. While female mice were potentially slightly more variable in water-maze acquisition and in the open field, males tended to perform less reliably in the water-maze probe trial. In addition to evaluating variability, we also directly compared mean performance of female and male mice and found them to be equivalent in both water-maze place navigation and open field exploration. Our data confirm and extend other large scale studies in demonstrating that including female mice in experiments does not cause a relevant increase of data variability. Our results make a strong case for including mice of both sexes whenever open field or water-maze are used in preclinical research. © 2017 The Authors. American Journal of Medical Genetics Part C Published by Wiley Periodicals, Inc.
Meijer, Piet; Kynde, Karin; van den Besselaar, Antonius M H P; Van Blerk, Marjan; Woods, Timothy A L
2018-04-12
This study was designed to obtain an overview of the analytical quality of the prothrombin time, reported as international normalized ratio (INR) and to assess the variation of INR results between European laboratories, the difference between Quick-type and Owren-type methods and the effect of using local INR calibration or not. In addition, we assessed the variation in INR results obtained for a single donation in comparison with a pool of several plasmas. A set of four different lyophilized plasma samples were distributed via national EQA organizations to participating laboratories for INR measurement. Between-laboratory variation was lower in the Owren group than in the Quick group (on average: 6.7% vs. 8.1%, respectively). Differences in the mean INR value between the Owren and Quick group were relatively small (<0.20 INR). Between-laboratory variation was lower after local INR calibration (CV: 6.7% vs. 8.6%). For laboratories performing local calibration, the between-laboratory variation was quite similar for the Owren and Quick group (on average: 6.5% and 6.7%, respectively). Clinically significant differences in INR results (difference in INR>0.5) were observed between different reagents. No systematic significant differences in the between-laboratory variation for a single-plasma sample and a pooled plasma sample were observed. The comparability for laboratories using local calibration of their thromboplastin reagent is better than for laboratories not performing local calibration. Implementing local calibration is strongly recommended for the measurement of INR.
Hoffman, Robert A; Wang, Lili; Bigos, Martin; Nolan, John P
2012-09-01
Results from a standardization study cosponsored by the International Society for Advancement of Cytometry (ISAC) and the US National Institute of Standards and Technology (NIST) are reported. The study evaluated the variability of assigning intensity values to fluorophore standard beads by bead manufacturers and the variability of cross calibrating the standard beads to stained polymer beads (hard-dyed beads) using different flow cytometers. Hard dyed beads are generally not spectrally matched to the fluorophores used to stain cells, and spectral response varies among flow cytometers. Thus if hard dyed beads are used as fluorescence calibrators, one expects calibration for specific fluorophores (e.g., FITC or PE) to vary among different instruments. Using standard beads surface-stained with specific fluorophores (FITC, PE, APC, and Pacific Blue™), the study compared the measured intensity of fluorophore standard beads to that of hard dyed beads through cross calibration on 133 different flow cytometers. Using robust CV as a measure of variability, the variation of cross calibrated values was typically 20% or more for a particular hard dyed bead in a specific detection channel. The variation across different instrument models was often greater than the variation within a particular instrument model. As a separate part of the study, NIST and four bead manufacturers used a NIST supplied protocol and calibrated fluorophore solution standards to assign intensity values to the fluorophore beads. Values assigned to the reference beads by different groups varied by orders of magnitude in most cases, reflecting differences in instrumentation used to perform the calibration. The study concluded that the use of any spectrally unmatched hard dyed bead as a general fluorescence calibrator must be verified and characterized for every particular instrument model. Close interaction between bead manufacturers and NIST is recommended to have reliable and uniformly assigned fluorescence standard beads. Copyright © 2012 International Society for Advancement of Cytometry.
Cabezas-Garcia, E H; Krizsan, S J; Shingfield, K J; Huhtanen, P
2017-06-01
A meta-analysis based on an individual-cow data set was conducted to investigate the effects of between-cow variation and related animal variables on predicted CH 4 emissions from dairy cows. Data were taken from 40 change-over studies consisting of a total of 637 cow/period observations. Animal production and rumen fermentation characteristics were measured for 154 diets in 40 studies; diet digestibility was measured for 135 diets in 34 studies, and ruminal digestion kinetics was measured for 56 diets in 15 studies. The experimental diets were based on grass silage, with cereal grains or by-products as energy supplements, and soybean or canola meal as protein supplements. Average forage:concentrate ratio across all diets on a dry matter basis was 59:41. Methane production was predicted from apparently fermented substrate using stoichiometric principles. Data were analyzed by mixed-model regression using diet and period within experiment as random effects, thereby allowing the effect of experiment, diet, and period to be excluded. Dry matter intake and milk yield were more repeatable experimental measures than rumen fermentation, nutrient outflow, diet digestibility, or estimated CH 4 yield. Between-cow coefficient of variation (CV) was 0.010 for stoichiometric CH 4 per mol of volatile fatty acids and 0.067 for predicted CH 4 yield (CH 4 /dry matter intake). Organic matter digestibility (OMD) also displayed little between-cow variation (CV = 0.013), indicating that between-cow variation in diet digestibility and rumen fermentation pattern do not markedly contribute to between cow-variation in CH 4 yield. Digesta passage rate was much more variable (CV = 0.08) between cows than OMD or rumen fermentation pattern. Increased digesta passage rate is associated with improved energetic efficiency of microbial N synthesis, which partitions fermented substrate from volatile fatty acids and gases to microbial cells that are more reduced than fermented carbohydrates. Positive relationships were observed between CH 4 per mol of volatile fatty acids versus OMD and rumen ammonia N concentration versus OMD; and negative relationships between the efficiency of microbial N synthesis versus OMD and digesta passage rate versus OMD, suggesting that the effects of these variables on CH 4 yield were additive. It can be concluded that variations in OMD and efficiency in microbial N synthesis resulting from variations in digesta passage contribute more to between-animal variation in CH 4 emissions than rumen fermentation pattern. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Bayram, Ezgi; Akyilmaz, Erol
2014-12-01
In the biosensor construction, 3-mercaptopropionic acid (3-MPA) and 6-aminocaproic acid (6-ACA) were used for forming self-assembled monolayer (SAM) on a gold disc electrode and pyruvate oxidase was immobilized on the modified electrode surface by using glutaraldehyde. Biosensor response is linearly related to pyruvate concentration at 2.5-50 μM, detection limit is 1.87 μM and response time of the biosensor is 6 s for differential pulse voltammograms. From the repeatability studies (n = 6) for 30.0 μM pyruvate revealed that the average value ([Formula: see text]), standard deviation (S.D) and coefficient of variation (CV %) were calculated to be 31.02 μM, ± 0.1914 μM and 0.62%, respectively.
NASA Technical Reports Server (NTRS)
Guimon, R. Kyle; Symes, Steven J. K.; Sears, Derek W. G.
1995-01-01
The induced thermoluminescence (TL) properties of 16 CV and CV-related chondrites, four CK chondrites and Renazzo (CR2) have been measured in order to investigate their metamorphic history. The petrographic, mineralogical and bulk compositional differences among the CV chondrites indicate that the TL sensitivity of the approximately 130 C TL peak is reflecting the abundance of ordered feldspar, especially in chondrule mesostasis, which in turn reflects parent-body metamorphism. The TL properties of 18 samples of homogenized Allende powder heated at a variety of times and temperatures, and cathodoluminescence mosaics of Axtell and Coolidge, showed results consistent with this conclusion. Five refractory inclusions from Allende, and separates from those inclusions, were also examined and yielded trends reflecting variations in mineralogy indicative of high peak temperatures (either metamorphic or igneous) and fairly rapid cooling. The CK chondrites are unique among metamorphosed chondrites in showing no detectable induced TL, which is consistent with literature data that suggests very unusual feldspar in these meteorites. Using TL sensitivity and several mineral systems and allowing for the differences in the oxidized and reduced subgroups, the CV and CV-related meteorites can be divided into petrologic types analogous to those of the ordinary and CO type 3 chondrites. Axtell, Kaba, Leoville, Bali, Arch and ALHA81003 are type 3.0-3.1, while ALH84018, Efremovka, Grosnaja, Allende and Vigarano are type 3.2-3.3 and Coolidge and Loongana 001 are type 3.8. Mokoia is probably a breccia with regions ranging in petrologic type from 3.0 to 3.2. Renazzo often plots at the end of the reduced and oxidized CV chondrite trends, even when those trends diverge, suggesting that in many respects it resembles the unmetamorphosed precursors of the CV chondrites. The low-petrographic types and low-TL peak temperatures of all samples, including the CV3.8 chondrites, indicates metamorphism in the stability field of low feldspar (i.e., less than 800 C) and a metamorphic history similar to that of the CO chondrites but unlike that of the ordinary chondrites.
Duff, W.R.D.; Björkman, K.M.; Kawalilak, C.E.; Kehrig, A.M.; Wiebe, S.; Kontulainen, S.
2017-01-01
Objectives: To define pQCT precision errors, least-significant-changes, and identify associated factors for bone outcomes at the radius and tibia in children. Methods: We obtained duplicate radius and tibia pQCT scans from 35 children (8-14yrs). We report root-mean-squared coefficient of variation (CV%RMS) and 95% limits-of-agreement to characterize repeatability across scan quality and least-significant-changes for bone outcomes at distal (total and trabecular area, content and density; and compressive bone strength) and shaft sites (total area and content; cortical area content, density and thickness; and torsional bone strength). We used Spearman’s rho to identify associations between CV% and time between measurements, child’s age or anthropometrics. Results: After excluding unanalyzable scans (6-10% of scans per bone site), CV%RMS ranged from 4% (total density) to 19% (trabecular content) at the distal radius, 4% (cortical content) to 8% (cortical thickness) at the radius shaft, 2% (total density) to 14% (trabecular content) at the distal tibia and from 2% (cortical content) to 6% (bone strength) at the tibia shaft. Precision errors were within 95% limits-of-agreement across scan quality. Age was associated (rho -0.4 to -0.5, p <0.05) with CV% at the tibia. Conclusion: Bone density outcomes and cortical bone properties appeared most precise (CV%RMS <5%) in children. PMID:28574412
Boner, Pamela L; Liu, Dave D W; Feely, William F; Robinson, Robert A; Wu, Jinn
2003-12-17
An accurate, reliable, and reproducible assay was developed and validated to determine flunixin in bovine liver, kidney, muscle, and fat. The overall recovery and percent coefficient of variation (%CV) of twenty-eight determinations in each tissue for flunixin free acid were 85.9% (5.9% CV) for liver, 94.6% (9.9% CV) for kidney, 87.4% (4.7% CV) for muscle, and 87.6% (4.4% CV) for fat. The theoretical limit of detection was 0.1 microg/kg (ppb, ng/g) for liver and kidney, and 0.2 ppb for muscle and fat. The theoretical limit of quantitation was 0.3, 0.2, 0.6, and 0.4 ppb for liver, kidney, muscle, and fat, respectively. The validated lower limit of quantitation was 1 ppb for edible tissues with the upper limit of 400 ppb for liver and kidney, 100 ppb for fat, and 40 ppb for muscle. Accuracy, precision, linearity, specificity, ruggedness, and storage stability were demonstrated. Briefly, the method involves an initial acid hydrolysis, followed by pH adjustment ( approximately 9.5) and partitioning with ethyl acetate. A portion of the ethyl acetate extract was purified by solid-phase extraction using a strong cation exchange cartridge. The eluate was then evaporated to dryness, reconstituted, and analyzed using LC/MS/MS. The validated method is sensitive and specific for flunixin in edible bovine tissue.
Estimating ages of Utah chubs by use of pectoral fin rays, otoliths, and scales
Griffin, Kayla M; Beard, Zachary S.; Flinders, John M.; Quist, Michael C.
2017-01-01
Utah chub Gila atraria is native to the Upper Snake River system in Wyoming and Idaho and to the Lake Bonneville Basin in Utah and southeastern Idaho. However, the Utah chub has been introduced into many other waterbodies in the western United States, where it competes with ecologically and economically important species. The objectives of this study were to evaluate between-reader precision and reader confidence in age estimates obtained from pectoral fin rays, lapilli (otoliths), asterisci (otoliths), and scales for Utah chubs collected from Henrys Lake, Idaho. Lapilli have been previously shown to provide accurate age estimates for Utah chubs; therefore, we sought to compare age estimates from fin rays, asterisci, and scales to those from lapilli. The between-reader coefficient of variation (CV) in age estimates was lowest and the percent of exact reader agreement (PA-0) was highest for pectoral fin rays (CV = 4.7, PA-0 = 74%), followed by scales (CV = 10.3, PA-0 = 52.3%), lapilli (CV = 11.6, PA-0 = 48.2%), and asterisci (CV = 13.0, PA-0 = 41.7%). Consensus age estimates from pectoral fin rays showed high concordance with consensus age estimates from lapilli. Our results indicate that pectoral fin rays provide the most precise age estimates for Utah chub. Pectoral fin rays are easily collected and processed and also provide age estimates without requiring fish sacrifice.
Reliability and variability of day-to-day vault training measures in artistic gymnastics.
Bradshaw, Elizabeth; Hume, Patria; Calton, Mark; Aisbett, Brad
2010-06-01
Inter-day training reliability and variability in artistic gymnastics vaulting was determined using a customised infra-red timing gate and contact mat timing system. Thirteen Australian high performance gymnasts (eight males and five females) aged 11-23 years were assessed during two consecutive days of normal training. Each gymnast completed a number of vault repetitions per daily session. Inter-day variability of vault run-up velocities (at -18 to -12 m, -12 to -6 m, -6 to -2 m, and -2 to 0 m from the nearest edge of the beat board), and board contact, pre-flight, and table contact times were determined using mixed modelling statistics to account for random (within-subject variability) and fixed effects (gender, number of subjects, number of trials). The difference in the mean (Mdiff) and Cohen's effect sizes for reliability assessment and intra-class correlation coefficients, and the coefficient of variation percentage (CV%) were calculated for variability assessment. Approach velocity (-18 to -2m, CV = 2.4-7.8%) and board contact time (CV = 3.5%) were less variable measures when accounting for day-to-day performance differences, than pre-flight time (CV = 17.7%) and table contact time (CV = 20.5%). While pre-flight and table contact times are relevant training measures, approach velocity and board contact time are more reliable when quantifying vaulting performance.
Laterally inhomogeneous barrier analysis of cu/n-gap/al schottky devices
NASA Astrophysics Data System (ADS)
Çınar Demir, K.; Coşkun, C.; Kurudirek, S. V.; Öz, S.; Aydoğan, Ş.; Biber, M.
2016-04-01
In this study, we examined the electrical parameters of Cu/n-GaP/Al Schottky structures at room temperature and examined the electrical characterization of these devices depending on and Capacitance-Voltage (C-V) and Current-Voltage (I-V) measurements. A statistical study on the experimental ideality factor (n) and BHs(barrier heights) values of the devices was stated. The n and BHs of all contacts have been determined from the electrical characteristics. Even though all of the diodes were conformably prepared, there was a diode-todiode variation: the effective BHs changed from 0.988-0.07 to 1.216-0.07 eV, and the n from 1.01-0.299 to 2.16-0.299. The yielded results show that the mean electrical parameters of Schottky devices are different from one diode to another, even if they are identically prepared. It can be axplained that the lower BHs usher with the higher n values owing to inhomogeneities.
Khaw, Mel W.; Grab, Denise A.; Livermore, Michael A.; Vossler, Christian A.; Glimcher, Paul W.
2015-01-01
Environmental public goods—including national parks, clean air/water, and ecosystem services—provide substantial benefits on a global scale. These goods have unique characteristics in that they are typically “nonmarket” goods, with values from both use and passive use that accrue to a large number of individuals both in current and future generations. In this study, we test the hypothesis that neural signals in areas correlated with subjective valuations for essentially all other previously studied categories of goods (ventromedial prefrontal cortex and ventral striatum) also correlate with environmental valuations. We use contingent valuation (CV) as our behavioral tool for measuring valuations of environmental public goods. CV is a standard stated preference approach that presents survey respondents with information on an issue and asks questions that help policymakers determine how much citizens are willing to pay for a public good or policy. We scanned human subjects while they viewed environmental proposals, along with three other classes of goods. The presentation of all four classes of goods yielded robust and similar patterns of temporally synchronized brain activation within attentional networks. The activations associated with the traditional classes of goods replicate previous correlations between neural activity in valuation areas and behavioral preferences. In contrast, CV-elicited values for environmental proposals did not correlate with brain activity at either the individual or population level. For a sub-population of participants, CV-elicited values were correlated with activity within the dorsomedial prefrontal cortex, a region associated with cognitive control and shifting decision strategies. The results show that neural activity associated with the subjective valuation of environmental proposals differs profoundly from the neural activity associated with previously examined goods and preference measures. PMID:26221734
NASA Astrophysics Data System (ADS)
Jeter, G. W.; Carter, G. A.
2013-12-01
Guy (Will) Wilburn Jeter Jr., Gregory A. Carter University of Southern Mississippi Geography and Geology Gulf Coast Geospatial Center The over-arching goal of this research is to assess habitat change over a seventy year period to better understand the combined effects of global sea level rise and storm impacts on the stability of Horn Island, MS habitats. Historical aerial photography is often overlooked as a resource for use in determining habitat change. However, the spatial information provided even by black and white imagery can give insight into past habitat composition via textural analysis. This research will evaluate characteristic dimensions; most notably patch size of habitat types using simple geo-statistics and textures of brightness values of historical aerial imagery. It is assumed that each cover type has an identifiable patch size that can be used as a unique classifier of each habitat type. Analytical methods applied to the 1940 imagery were developed using 2010 field data and USDA aerial imagery. Textural moving window methods and basic geo-statistics were used to estimate characteristic dimensions of each cover type in 1940 aerial photography. The moving window texture analysis was configured with multiple window sizes to capture the characteristic dimensions of six habitat types; water, bare sand , dune herb land, estuarine shrub land, marsh land and slash pine woodland. Coefficient of variation (CV), contrast, and entropy texture filters were used to analyze the spatial variability of the 1940 and 2010 imagery. (CV) was used to depict the horizontal variability of each habitat characteristic dimension. Contrast was used to represent the variability of bright versus dark pixel values; entropy was used to show the variation in the slash pine woodland habitat type. Results indicate a substantial increase in marshland habitat relative to other habitat types since 1940. Results also reveal each habitat-type, such as dune herb-land, marsh-land, estuarine shrub-land, bare sand, slash pine woodland, and water exhibit a characteristic dimension that may be estimated from horizontal variability in image brightness values. These characteristic dimensions are estimated at less than one 1 meter for marsh-land bare sand and water, 3 meters for estuarine shrub-land and dune herb-land, and 5 to 7 meters for slash pine woodland.
Paaso, Ulla; Keski-Saari, Sarita; Keinänen, Markku; Karvinen, Heini; Silfver, Tarja; Rousi, Matti; Mikola, Juha
2017-01-01
Abundant secondary metabolites, such as condensed tannins, and their interpopulation genotypic variation can remain through plant leaf senescence and affect litter decomposition. Whether the intrapopulation genotypic variation of a more diverse assortment of secondary metabolites equally persists through leaf senescence and litter decomposition is not well understood. We analyzed concentrations of intracellular phenolics, epicuticular flavonoid aglycones, epicuticular triterpenoids, condensed tannins, and lignin in green leaves, senescent leaves and partly decomposed litter of silver birch, Betula pendula . Broad-sense heritability ( H 2 ) and coefficient of genotypic variation ( CV G ) were estimated for metabolites in senescent leaves and litter using 19 genotypes selected from a B. pendula population in southern Finland. We found that most of the secondary metabolites remained through senescence and decomposition and that their persistence was related to their chemical properties. Intrapopulation H 2 and CV G for intracellular phenolics, epicuticular flavonoid aglycones and condensed tannins were high and remarkably, increased from senescent leaves to decomposed litter. The rank of genotypes in metabolite concentrations was persistent through litter decomposition. Lignin was an exception, however, with a diminishing genotypic variation during decomposition, and the concentrations of lignin and condensed tannins had a negative genotypic correlation in the senescent leaves. Our results show that secondary metabolites and their intrapopulation genotypic variation can for the most part remain through leaf senescence and early decomposition, which is a prerequisite for initial litter quality to predict variation in litter decomposition rates. Persistent genotypic variation also opens an avenue for selection to impact litter decomposition in B. pendula populations through acting on their green foliage secondary chemistry. The negative genotypic correlations and diminishing heritability of lignin concentrations may, however, counteract this process.
Schultz, Martin G; Otahal, Petr; Cleland, Verity J; Blizzard, Leigh; Marwick, Thomas H; Sharman, James E
2013-03-01
The prognostic relevance of a hypertensive response to exercise (HRE) is ill-defined in individuals undergoing exercise stress testing. The study described here was intended to provide a systematic review and meta-analysis of published literature to determine the value of exercise-related blood pressure (BP) (independent of office BP) for predicting cardiovascular (CV) events and mortality. Online databases were searched for published longitudinal studies reporting exercise-related BP and CV events and mortality rates. We identified for review 12 longitudinal studies with a total of 46,314 individuals without significant coronary artery disease, with total CV event and mortality rates recorded over a mean follow-up of 15.2±4.0 years. After adjustment for age, office BP, and CV risk factors, an HRE at moderate exercise intensity carried a 36% greater rate of CV events and mortality (95% CI, 1.02-1.83, P = 0.039) than that of subjects without an HRE. Additionally, each 10mm Hg increase in systolic BP during exercise at moderate intensity was accompanied by a 4% increase in CV events and mortality, independent of office BP, age, or CV risk factors (95% CI, 1.01-1.07, P = 0.02). Systolic BP at maximal workload was not significantly associated with the outcome of an increased rate of CV, whether analyzed as a categorical (HR=1.49, 95% CI, 0.90-2.46, P = 0.12) or a continuous (HR=1.01, 95% CI, 0.98-1.04, P = 0.53) variable. An HRE at moderate exercise intensity during exercise stress testing is an independent risk factor for CV events and mortality. This highlights the need to determine underlying pathophysiological mechanisms of exercise-induced hypertension.
Takahashi, Saki; Liao, Qiaohong; Van Boeckel, Thomas P.; Xing, Weijia; Sun, Junling; Hsiao, Victor Y.; Metcalf, C. Jessica E.; Chang, Zhaorui; Liu, Fengfeng; Zhang, Jing; Wu, Joseph T.; Cowling, Benjamin J.; Leung, Gabriel M.; Farrar, Jeremy J.; van Doorn, H. Rogier; Grenfell, Bryan T.; Yu, Hongjie
2016-01-01
Background Hand, foot, and mouth disease (HFMD) is a common childhood illness caused by serotypes of the Enterovirus A species in the genus Enterovirus of the Picornaviridae family. The disease has had a substantial burden throughout East and Southeast Asia over the past 15 y. China reported 9 million cases of HFMD between 2008 and 2013, with the two serotypes Enterovirus A71 (EV-A71) and Coxsackievirus A16 (CV-A16) being responsible for the majority of these cases. Three recent phase 3 clinical trials showed that inactivated monovalent EV-A71 vaccines manufactured in China were highly efficacious against HFMD associated with EV-A71, but offered no protection against HFMD caused by CV-A16. To better inform vaccination policy, we used mathematical models to evaluate the effect of prospective vaccination against EV-A71-associated HFMD and the potential risk of serotype replacement by CV-A16. We also extended the model to address the co-circulation, and implications for vaccination, of additional non-EV-A71, non-CV-A16 serotypes of enterovirus. Methods and Findings Weekly reports of HFMD incidence from 31 provinces in Mainland China from 1 January 2009 to 31 December 2013 were used to fit multi-serotype time series susceptible–infected–recovered (TSIR) epidemic models. We obtained good model fit for the two-serotype TSIR with cross-protection, capturing the seasonality and geographic heterogeneity of province-level transmission, with strong correlation between the observed and simulated epidemic series. The national estimate of the basic reproduction number, R 0, weighted by provincial population size, was 26.63 for EV-A71 (interquartile range [IQR]: 23.14, 30.40) and 27.13 for CV-A16 (IQR: 23.15, 31.34), with considerable variation between provinces (however, predictions about the overall impact of vaccination were robust to this variation). EV-A71 incidence was projected to decrease monotonically with higher coverage rates of EV-A71 vaccination. Across provinces, CV-A16 incidence in the post-EV-A71-vaccination period remained either comparable to or only slightly increased from levels prior to vaccination. The duration and strength of cross-protection following infection with EV-A71 or CV-A16 was estimated to be 9.95 wk (95% confidence interval [CI]: 3.31, 23.40) in 68% of the population (95% CI: 37%, 96%). Our predictions are limited by the necessarily short and under-sampled time series and the possible circulation of unidentified serotypes, but, nonetheless, sensitivity analyses indicate that our results are robust in predicting that the vaccine should drastically reduce incidence of EV-A71 without a substantial competitive release of CV-A16. Conclusions The ability of our models to capture the observed epidemic cycles suggests that herd immunity is driving the epidemic dynamics caused by the multiple serotypes of enterovirus. Our results predict that the EV-A71 and CV-A16 serotypes provide a temporary immunizing effect against each other. Achieving high coverage rates of EV-A71 vaccination would be necessary to eliminate the ongoing transmission of EV-A71, but serotype replacement by CV-A16 following EV-A71 vaccination is likely to be transient and minor compared to the corresponding reduction in the burden of EV-A71-associated HFMD. Therefore, a mass EV-A71 vaccination program of infants and young children should provide significant benefits in terms of a reduction in overall HFMD burden. PMID:26882540
Takahashi, Saki; Liao, Qiaohong; Van Boeckel, Thomas P; Xing, Weijia; Sun, Junling; Hsiao, Victor Y; Metcalf, C Jessica E; Chang, Zhaorui; Liu, Fengfeng; Zhang, Jing; Wu, Joseph T; Cowling, Benjamin J; Leung, Gabriel M; Farrar, Jeremy J; van Doorn, H Rogier; Grenfell, Bryan T; Yu, Hongjie
2016-02-01
Hand, foot, and mouth disease (HFMD) is a common childhood illness caused by serotypes of the Enterovirus A species in the genus Enterovirus of the Picornaviridae family. The disease has had a substantial burden throughout East and Southeast Asia over the past 15 y. China reported 9 million cases of HFMD between 2008 and 2013, with the two serotypes Enterovirus A71 (EV-A71) and Coxsackievirus A16 (CV-A16) being responsible for the majority of these cases. Three recent phase 3 clinical trials showed that inactivated monovalent EV-A71 vaccines manufactured in China were highly efficacious against HFMD associated with EV-A71, but offered no protection against HFMD caused by CV-A16. To better inform vaccination policy, we used mathematical models to evaluate the effect of prospective vaccination against EV-A71-associated HFMD and the potential risk of serotype replacement by CV-A16. We also extended the model to address the co-circulation, and implications for vaccination, of additional non-EV-A71, non-CV-A16 serotypes of enterovirus. Weekly reports of HFMD incidence from 31 provinces in Mainland China from 1 January 2009 to 31 December 2013 were used to fit multi-serotype time series susceptible-infected-recovered (TSIR) epidemic models. We obtained good model fit for the two-serotype TSIR with cross-protection, capturing the seasonality and geographic heterogeneity of province-level transmission, with strong correlation between the observed and simulated epidemic series. The national estimate of the basic reproduction number, R0, weighted by provincial population size, was 26.63 for EV-A71 (interquartile range [IQR]: 23.14, 30.40) and 27.13 for CV-A16 (IQR: 23.15, 31.34), with considerable variation between provinces (however, predictions about the overall impact of vaccination were robust to this variation). EV-A71 incidence was projected to decrease monotonically with higher coverage rates of EV-A71 vaccination. Across provinces, CV-A16 incidence in the post-EV-A71-vaccination period remained either comparable to or only slightly increased from levels prior to vaccination. The duration and strength of cross-protection following infection with EV-A71 or CV-A16 was estimated to be 9.95 wk (95% confidence interval [CI]: 3.31, 23.40) in 68% of the population (95% CI: 37%, 96%). Our predictions are limited by the necessarily short and under-sampled time series and the possible circulation of unidentified serotypes, but, nonetheless, sensitivity analyses indicate that our results are robust in predicting that the vaccine should drastically reduce incidence of EV-A71 without a substantial competitive release of CV-A16. The ability of our models to capture the observed epidemic cycles suggests that herd immunity is driving the epidemic dynamics caused by the multiple serotypes of enterovirus. Our results predict that the EV-A71 and CV-A16 serotypes provide a temporary immunizing effect against each other. Achieving high coverage rates of EV-A71 vaccination would be necessary to eliminate the ongoing transmission of EV-A71, but serotype replacement by CV-A16 following EV-A71 vaccination is likely to be transient and minor compared to the corresponding reduction in the burden of EV-A71-associated HFMD. Therefore, a mass EV-A71 vaccination program of infants and young children should provide significant benefits in terms of a reduction in overall HFMD burden.
Using the orbiting companion to trace WR wind structures in the 29d WC8d + O8-9IV binary CV Ser
NASA Astrophysics Data System (ADS)
David-Uraz, Alexandre; Moffat, Anthony F. J.
2011-07-01
We have used continuous, high-precision, broadband visible photometry from the MOST satellite to trace wind structures in the WR component of CV Ser over more than a full orbit. Most of the small-scale light-curve variations are likely due to extinction by clumps along the line of sight to the O companion as it orbits and shines through varying columns of the WR wind. Parallel optical spectroscopy from the Mont Megantic Observatory is used to refine the orbital and wind-collision parameters, as well as to reveal line emission from clumps.
Tracing WR wind structures by using the orbiting companion in the 29d WC8d + O8-9IV binary CV Ser
NASA Astrophysics Data System (ADS)
David-Uraz, Alexandre; Moffat, Anthony F. J.; Chené, André Nicolas; Lange, Nicholas
2011-01-01
We have obtained continuous, high-precision, broadband visible photometry from the MOST satellite of CV Ser over more than a full orbit in order to link the small-scale light-curve variations to extinction due to wind structures in the WR component, thus permitting us to trace these structures. The light-curve presented unexpected characteristics, in particular eclipses with a varying depth. Parallel optical spectroscopy from the Mont Megantic Observatory and Dominion Astrophysical Observatory was obtained to refine the orbital and wind-collision parameters, as well as to reveal line emission from clumps.
NASA Technical Reports Server (NTRS)
Weinberg, I.; Hsu, L. C.
1977-01-01
Increased solar cell efficiencies are attained by reduction of surface recombination and variation of impurity concentration profiles at the n(+) surface of silicon solar cells. Diagnostic techniques are employed to evaluate the effects of specific materials preparation methodologies on surface and near surface concentrations. It is demonstrated that the MOS C-V method, when combined with a bulk measurement technique, yields more complete concentration data than are obtainable by either method alone. Specifically, new solar cell MOS C-V measurements are combined with bulk concentrations obtained by a successive layer removal technique utilizing measurements of sheet resistivity and Hall coefficient.
Parreño, Viviana; Romera, S Alejandra; Makek, Lucia; Rodriguez, Daniela; Malacari, Darío; Maidana, Silvina; Compaired, Diego; Combessies, Gustavo; Vena, María Marta; Garaicoechea, Lorena; Wigdorovitz, Andrés; Marangunich, Laura; Fernandez, Fernando
2010-10-01
Two ELISAs to quantify antibodies to BoHV-1 in the sera of cattle and immunized guinea pigs were developed and validated using ISO/IEC 17025 standards. The cut-off value of the assay was established at 20% positivity of a high positive control for screening of cattle. Using this threshold, the assay properly classified the OIE bovine reference sera EU1, EU2 and EU3. For vaccine potency testing, a cut-off of 40% was selected for both species. The reliability of the assays, given by their diagnostic sensitivity and specificity, using the threshold of 40% was 89.7% and 100%, respectively, for bovines and 94.9% and 100% for guinea pigs, respectively. There was almost perfect agreement between the ELISA and virus neutralization results. In addition, after vaccination, there was a good correlation between the neutralizing and ELISA antibody titers of the serum from the same bovine or guinea pig, sampled at 60 and 30 days post-vaccination, respectively (R(bovine)=0.88, R(guinea pig)=0.92; p<0.0001). A similar correlation was observed when analyzing the mean antibody titers of groups of vaccinated animals (R(bovine)=0.95 and R(guinea pig)=0.97; p<0.0001), indicating the relevance of the ELISAs for batch to batch vaccine potency testing in the target species and in the laboratory animal model. The intermediate precision of the assays expressed as the relative coefficient of variation (CV) of the positive control assayed over a 3-year period in the same laboratory was 22.2% for bovines and 23.1% for guinea pigs. The reproducibility of both techniques obtained in inter-laboratory assays was CV=12.4% for bovines and CV approximately 0 for guinea pigs, which met the requirements of the OIE (CV<30%). The validated ELISAs represent important methods for vaccine potency testing and for controlling BoHV-1 infections. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Kloppenburg, W D; Wolthers, B G; Stellaard, F; Elzinga, H; Tepper, T; de Jong, P E; Huisman, R M
1997-07-01
1. Stable urea isotopes can be used to study urea kinetics in humans. The use of stable urea isotopes for studying urea kinetic parameters in humans on a large scale is hampered by the high costs of the labelled material. We devised a urea dilution for measurement of the distribution volume, production rate and clearance of urea in healthy subjects and renal failure patients using the inexpensive single labelled [13C]urea isotope with subsequent analysis by headspace chromatography-isotope ratio MS (GC-IRMS) of the [13C]urea enrichment. 2. The method involves measurement of the molar percentage excess of [13C]urea in plasma samples taken over a 4 h period after an intravenous bolus injection of [13C]urea. During the sample processing procedure, the plasma samples together with calibration samples containing a known molar percentage excess of [13C]urea are acidified with phosphoric acid to remove endogenous CO2, and are subsequently incubated with urease to convert the urea present in the plasma samples into CO2. The 13C enrichment of the generated CO2 is analysed by means of GC-IRMS. This method allows measurement of the molar percentage excess of [13C]urea to an accuracy of 0.02%. 3. Reproducibility studies showed that the sample processing procedure [within-run coefficient of variation (CV) < 2.8% and between-run CV < 8.8%] and the GC-IRMS analysis (within-day CV < 1.3% and between-day CV < 1.3%) could be repeated with good reproducibility. 4. In clinical urea kinetic studies in a healthy subject and in a renal failure patient without residual renal function, reproducible values of the distribution volume, production rate and clearance of urea were determined using minimal amounts of [13C]urea (25-50 mg). 5. Because only low [13C]urea enrichments are needed in this urea dilution method using GC-IRMS analysis, the costs of urea kinetic studies are reduced considerably, especially in patients with renal failure.
2013-01-01
Background The aim was to compare the repeatability, reproducibility and inherent precision of ultrasound pachymetry (USP), noncontact specular microscopy (SP-2000P) and the Confoscan 4 confocal microscope (z-ring CS4) in measuring endothelial cell density (ECD), coefficient of variation of cell size (CV), and central corneal thickness (CCT) in normal eyes. Methods In this prospective study, one eye was selected from each of 30 subjects for the measurements of ECD, CV and CCT, which were taken by two observers. Results were analyzed statistically by repeated-measures analysis of variance (ANOVA) for intra-observer repeatability, inter-observer reproducibility, unpaired t-test, paired t-test, and Bland–Altman analyses to determine limits of agreement (LOA) between the three instruments. Results Mean ECD, measured by SP-2000P and z-ring CS4, were 3115.50 ± 279.70 cells/mm2 and 3167.50 ± 264.75 cells/mm2, respectively (observer 1), and 3192.63 ± 249.42 cells/mm2 (z-ring, observer 2). Mean CV measurements were 27.12 ± 2.51 and 27.10 ± 2.41 (SP-2000P and z-ring CS4, respectively; observer 1), and 27.17 ± 2.25 (z-ring, observer 2). Mean CCT values were 555.11 ± 35.83 μm (USP), 535.82 ± 41.10 μm (SP-2000P) and 552.57 ± 36.83 μm (z-ring CS4), and 554.97 ± 36.34 μm (z-ring CS4, observer 2). However, pairwise tests in all cases there was good repeatability and reproducibility as shown by inter-observer and intra-observer analysis of variance for each of the instruments. Conclusions The SP-2000P and the z-ring CS4 can be used interchangeably to measure ECD and CV. For CCT, the sample size was too small to test for differences of the CCT measurements between the three instruments. PMID:24274022
Mulè, Giuseppe; Castiglia, Antonella; Cusumano, Claudia; Scaduto, Emilia; Geraci, Giulio; Altieri, Dario; Di Natale, Epifanio; Cacciatore, Onofrio; Cerasola, Giovanni; Cottone, Santina
2017-01-01
The kidney is one of the major target organs of hypertension.Kidney damage represents a frequent event in the course of hypertension and arterial hypertension is one of the leading causes of end-stage renal disease (ESRD).ESRD has long been recognized as a strong predictor of cardiovascular (CV) morbidity and mortality. However, over the past 20 years a large and consistent body of evidence has been produced suggesting that CV risk progressively increases as the estimated glomerular filtration rate (eGFR) declines and is already significantly elevated even in the earliest stages of renal damage. Data was supported by the very large collaborative meta-analysis of the Chronic Kidney Disease Prognosis Consortium, which provided undisputable evidence that there is an inverse association between eGFR and CV risk. It is important to remember that in evaluating CV disease using renal parameters, GFR should be assessed simultaneously with albuminuria.Indeed, data from the same meta-analysis indicate that also increased urinary albumin levels or proteinuria carry an increased risk of all-cause and CV mortality. Thus, lower eGFR and higher urinary albumin values are not only predictors of progressive kidney failure, but also of all-cause and CV mortality, independent of each other and of traditional CV risk factors.Although subjects with ESRD are at the highest risk of CV diseases, there will likely be more events in subjects with mil-to-moderate renal dysfunction, because of its much higher prevalence.These findings are even more noteworthy when one considers that a mild reduction in renal function is very common in hypertensive patients.The current European Society of Hypertension (ESH)/European Society of Cardiology (ESC) guidelines for the management of arterial hypertension recommend to sought in every patient signs of subclinical (or asymptomatic) renal damage. This was defined by the detection of eGFR between 30 mL/min/1.73 m 2 and 60 mL/min/1.73 m 2 or the presence of microalbuminuria (MAU), that is an amount of albumin in the urine of 30-300 mg/day or an albumin/creatinine ratio, preferentially on morning spot urine, of 30-300 mg/g.There is clear evidence that urinary albumin excretion levels, even below the cut-off values used to define MAU, are associated with an increased risk of CV events. The relationships of MAU with a variety of risk factors, such as blood pressure, diabetes and metabolic syndrome and with several indices of subclinical organ damage, may contribute, at least in part, to explain the enhanced CV risk conferred by MAU. Nonetheless, several studies showed that the association between MAU and CV disease remains when all these risk factors are taken into account in multivariate analyses. Therefore, the exact pathophysiological mechanisms explaining the association between MAU and CV risk remain to be elucidated. The simple search for MAU and in general of subclinical renal involvement in hypertensive patients may enable the clinician to better assess absolute CV risk, and its identification may induce physicians to encourage patients to make healthy lifestyle changes and perhaps would prompt to more aggressive modification of standard CV risk factors.
An operational method for the real-time monitoring of E. coli numbers in bathing waters.
Lebaron, Philippe; Henry, A; Lepeuple, A-S; Pena, G; Servais, P
2005-06-01
The aim of this study was to investigate the potential application of the beta-d-glucuronidase (GLUase) activity measurement for the routine detection and quantification of E. coli in marine bathing waters. GLUase activity was measured as the rate of hydrolysis of 4-methylumbelliferyl-beta-d-glucuronide. Culturable E. coli were quantified by the most probable number (MPN) microplate method. Both methods were applied to a large set of seawater samples. Significant correlation was found between the log of GLUase activity and the log of culturable E. coli. The mean coefficient of variation (CV) of the GLUase activity was less than 15% at concentrations around the current standards of International regulations whereas the CV of the microplate method was around 30%. When samples were stored at 4 degrees C and 20 degrees C, the mean CV of the GLUase activity remained below 15% up to 6 hours after sample collection whereas the range of variation of the microplate method varied between 10 and 50%. We concluded that the GLUase activity is an operational, reproducible, simple, very rapid and low cost method for the real-time enumeration of E. coli in bathing waters and should be preferred to the microplate method. The GLUase activity method should be routinely applied to the rapid enumeration of E. coli in recreational waters and recommendations for its application were suggested to water quality managers.
Zheng, Hao; Gao, Jixi; Teng, Yanguo; Feng, Chaoyang; Tian, Meirong
2015-01-01
Drought and shortages of soil water are becoming extremely severe due to global climate change. A better understanding of the relationship between vegetation type and soil-moisture conditions is crucial for conserving soil water in forests and for maintaining a favorable hydrological balance in semiarid areas, such as the Saihanwula National Nature Reserve in Inner Mongolia, China. We investigated the temporal dynamics of soil moisture in this reserve to a depth of 40 cm under three types of vegetation during a period of rainwater recharge. Rainwater from most rainfalls recharged the soil water poorly below 40 cm, and the rainfall threshold for increasing the moisture content of surface soil for the three vegetations was in the order: artificial Larix spp. (AL) > Quercus mongolica (QM) > unused grassland (UG). QM had the highest mean soil moisture content (21.13%) during the monitoring period, followed by UG (16.52%) and AL (14.55%); and the lowest coefficient of variation (CV 9.6-12.5%), followed by UG (CV 10.9-18.7%) and AL (CV 13.9-21.0%). QM soil had a higher nutrient content and higher soil porosities, which were likely responsible for the higher ability of this cover to retain soil water. The relatively smaller QM trees were able to maintain soil moisture better in the study area. PMID:25781333
NASA Astrophysics Data System (ADS)
Watts, David
This dissertation studies electricity markets based on two-settlement systems and applies the concept of conjectural variation (CV) as a tool for representing different levels of competitiveness in the market. Some recent theoretical works are addressed to support the use of CV as a solution concept. A notion of consistency is introduced to make the level of competitiveness of the market endogenous, and allows finding consistent CV equilibria and the corresponding conditions for existence of equilibria. First, a case is studied in which firms hold exogenous levels of forward commitments. Then, backward induction and sub-game perfection are used to solve sequentially for the spot and forward market equilibrium. This allows analyzing how firms take positions in the forward market, based on considering their later impact on the spot market. It is concluded that positions taken in the forward market depend largely on firms expectations about the competitiveness of both the spot and the forward market. Forward markets are welfare enhancing even if they are not as competitive as the associated spot market as long as they are not too oligopolistie. The above formulation is used to model a dynamic scenario to analyze market stability, linking this research to Dr. Alvarado's earlier research on market stability. This brings about interesting trade offs between market power and market stability.
Muscle fibre conduction and fatigue during dynamic actions on a flywheel exercise device
NASA Astrophysics Data System (ADS)
Pozzo, Marco; Alkner, Bjorn; Norrbrand, Lena; Farina, Dario; Tesch, Per A.
2005-08-01
Exposure to microgravity has adverse effects on skeletal muscle size and function. Such effects can be counteracted by training using a Flywheel Exercise Device (FWED). Multichannel EMG signals were detected in nine males from vastus medialis and laterialis muscles during 30 coupled concentric (CON) and eccentric (ECC) actions on the FWED. Muscle fiber conduction velocity (CV) was assessed for each action. CV initial values depended on muscle action type (CON/ECC) and were higher in CON than ECC actions. CV decreased (P<0.05) over time during the task. Its slope was greater for VL than VM but was not different between CON and ECC. It was concluded that direct measure of CV is feasible during dynamic exercise, and that this technique may be used for objective assessment of the effect of resistance training in counteracting microgravity-induced muscle atrophy.
Cavero Carbonell, C; Zurriaga, O; Pérez Panadés, J; Barona Vilar, C; Martos Jiménez, C
2013-09-01
The objective of this study is to estimate the prevalence of congenital heart defects (CHD) in the Comunitat Valenciana (CV) in children less than one year old and identify whether there are temporal and geographic variations within this prevalence. The minimum basic data set from hospital discharge reports was used to select patients, who were born between 1999-2008, were less than one year old, and who lived in the CV with at least one hospital admission in which the primary diagnosis and/or any of the events were coded as CHD (codes 745-747 of the International Classification of Diseases 9th Revision Clinical Modification). The first hospital discharge report with CHD was selected, using the health card number to detect duplication. The prevalence and 95% confidence intervals were calculated, and the prevalence ratio (PR) and smoothed PR was obtained for each municipality to identify geographic patterns. In the period 1999-2008 there were 6.377 patients younger than one year with some CHD, representing the 43.2% of cases of congenital anomalies. The prevalence was 134.3 per 10.000 live births (95% CI: 131.1-137.6). There was a significant increase in the prevalence, from 115.8 in the 1999-2003 period to 149.5 in the 2004-2008 period. A higher risk was identified in the north of the CV, and in some municipalities of the province of Alicante, in the south. The observed increase in CHD agrees with the findings in other countries and it can be explained, at least in part, by improved diagnostic techniques. The geographic pattern identified requires a more detailed analysis that could explain the geographic variations found. Copyright © 2012 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Peters, A Michael; Howard, Bethany; Neilly, Mark D J; Seshadri, Nagabhushan; Sobnack, Ravin; Hooker, Claire A; Irwin, Andrew; Snelling, Hayley; Gruning, Thomas; Perry, Laura; Patel, Neva H; Lawson, Richard S; Shabo, Gregory; Williams, Nigel; Dave, Surendra; Barnfield, Mark C
2012-04-01
The objective of the study was to undertake a clinical audit of departmental performance in the measurement of glomerular filtration rate (GFR) using the coefficient of variation (CV) of extracellular fluid volume (ECFV) as the benchmark. ECFV is held within narrow limits in healthy subjects, narrower than GFR, and should therefore have a low CV. Fifteen departments participated in this retrospective study of healthy renal transplant donors. Data were analysed separately for men (n ranged from 28 to 115 per centre; total = 819) and women (n = 28-146; 1,059). All centres used the slope-intercept method with blood sample numbers ranging from two to five. Subjects did not fast prior to GFR measurement. GFR was scaled to body surface area (BSA) and corrected for the single compartment assumption. GFR scaled to ECFV was calculated as the terminal slope rate constant and corrected for the single compartment assumption. ECFV/BSA was calculated as the ratio of GFR/BSA to GFR/ECFV. The departmental CVs of ECFV/BSA and GFR/BSA ranged from 8.3 to 25.8% and 12.8 to 21.9%, respectively, in men, and from 9.6 to 21.1% and 14.8 to 23.7%, respectively, in women. Both CVs correlated strongly between men and women from the same centre, suggesting department-specific systematic errors. GFR/BSA was higher in men in 14 of 15 centres, whereas GFR/ECFV was higher in women in 14 of 15 centres. Both correlated strongly between men and women, suggesting regional variation in GFR. The CV of ECFV/BSA in normal subjects is a useful indicator of the technical robustness with which GFR is measured and, in this study, indicated a wide variation in departmental performance.
ERIC Educational Resources Information Center
Oranje, Andreas
2006-01-01
A multitude of methods has been proposed to estimate the sampling variance of ratio estimates in complex samples (Wolter, 1985). Hansen and Tepping (1985) studied some of those variance estimators and found that a high coefficient of variation (CV) of the denominator of a ratio estimate is indicative of a biased estimate of the standard error of a…
Georgieva, Nedyalka; Yaneva, Zvezdelina; Dermendzhieva, Diyana
2017-09-01
The aim of the present study was to develop cresyl violet (CV)/bentonite composite system, to investigate the equilibrium sorption of the fluorescent dye on bentonite, to determine the characteristic equilibrium and thermodynamic parameters of the system by appropriate empirical isotherm models and to assess its pH-indicator properties. The absorption characteristics of CV solutions were investigated by UV/VIS spectrophotometer. Equilibrium experiments were conducted and the experimental data were modelled by six mathematical isotherm models. The analyses of the experimental data showed that bentonite exhibited significantly high capacity - 169.92 mg/g, towards CV. The encapsulation efficiency was 85%. The Langmuir, Flory-Huggins and El-Awady models best represented the experimental results. The free Gibbs energy of adsorption (ΔG o ) was calculated on the basis of the values of the equilibrium coefficients determined by the proposed models. The values of ΔG determined by the Langmuir, Temkin and Flory-Huggins models are within the range -20 to -40 kJ/mol, which indicates that the adsorption process is spontaneous and chemisorption takes place due to charge sharing or transfer from the dye molecules to the sorbent surface as a coordinate type of bond. The investigations of the obtained CV/bentonite hybrid systems for application as pH-markers showed satisfactory results.
Yu, Shuling; Yuan, Xuejie; Yang, Jing; Yuan, Jintao; Shi, Jiahua; Wang, Yali; Chen, Yuewen; Gao, Shufang
2015-01-01
An attractive method of generating second-order data was developed by a dropping technique to generate pH gradient simultaneously coupled with diode-array spectrophotometer scanning. A homemade apparatus designed for the pH gradient. The method and the homemade apparatus were used to simultaneously determine malachite green (MG) and crystal violet (CV) in water samples. The absorbance-pH second-order data of MG or CV were obtained from the spectra of MG or CV in a series of pH values of HCl-KCl solution. The second-order data of mixtures containing MG and CV that coexisted with interferents were analyzed using multidimensional partial least-squares with residual bilinearization. The method and homemade apparatus were used to simultaneously determine MG and CV in fish farming water samples and in river ones with satisfactory results. The presented method and the homemade apparatus could serve as an alternative tool to handle some analysis problems. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Lingqin, E-mail: lqhuang@jsnu.edu.cn, E-mail: dwang121@dlut.edu.cn; Wang, Dejun, E-mail: lqhuang@jsnu.edu.cn, E-mail: dwang121@dlut.edu.cn
The barrier characteristics of Pt contacts to relatively highly doped (∼1 × 10{sup 18 }cm{sup −3}) 4H-SiC were investigated using current-voltage (I-V) and capacitance-voltage (C-V) measurements in the temperature range of 160–573 K. The barrier height and ideally factor estimated from the I-V characteristics based on the thermionic emission model are abnormally temperature-dependent, which can be explained by assuming the presence of a double Gaussian distribution (GD) of inhomogeneous barrier heights. However, in the low temperature region (160–323 K), the obtained mean barrier height according to GD is lower than the actual mean value from C-V measurement. The values of barrier height determined from themore » thermionic field emission model are well consistent with those from the C-V measurements, which suggest that the current transport process could be modified by electron tunneling at low temperatures.« less
Optimizing Controlling-Value-Based Power Gating with Gate Count and Switching Activity
NASA Astrophysics Data System (ADS)
Chen, Lei; Kimura, Shinji
In this paper, a new heuristic algorithm is proposed to optimize the power domain clustering in controlling-value-based (CV-based) power gating technology. In this algorithm, both the switching activity of sleep signals (p) and the overall numbers of sleep gates (gate count, N) are considered, and the sum of the product of p and N is optimized. The algorithm effectively exerts the total power reduction obtained from the CV-based power gating. Even when the maximum depth is kept to be the same, the proposed algorithm can still achieve power reduction approximately 10% more than that of the prior algorithms. Furthermore, detailed comparison between the proposed heuristic algorithm and other possible heuristic algorithms are also presented. HSPICE simulation results show that over 26% of total power reduction can be obtained by using the new heuristic algorithm. In addition, the effect of dynamic power reduction through the CV-based power gating method and the delay overhead caused by the switching of sleep transistors are also shown in this paper.
Estimating the Cost of Providing Foundational Public Health Services.
Mamaril, Cezar Brian C; Mays, Glen P; Branham, Douglas Keith; Bekemeier, Betty; Marlowe, Justin; Timsina, Lava
2017-12-28
To estimate the cost of resources required to implement a set of Foundational Public Health Services (FPHS) as recommended by the Institute of Medicine. A stochastic simulation model was used to generate probability distributions of input and output costs across 11 FPHS domains. We used an implementation attainment scale to estimate costs of fully implementing FPHS. We use data collected from a diverse cohort of 19 public health agencies located in three states that implemented the FPHS cost estimation methodology in their agencies during 2014-2015. The average agency incurred costs of $48 per capita implementing FPHS at their current attainment levels with a coefficient of variation (CV) of 16 percent. Achieving full FPHS implementation would require $82 per capita (CV=19 percent), indicating an estimated resource gap of $34 per capita. Substantial variation in costs exists across communities in resources currently devoted to implementing FPHS, with even larger variation in resources needed for full attainment. Reducing geographic inequities in FPHS may require novel financing mechanisms and delivery models that allow health agencies to have robust roles within the health system and realize a minimum package of public health services for the nation. © Health Research and Educational Trust.
Refuse derived fuel potential in DKI Jakarta
NASA Astrophysics Data System (ADS)
Widyatmoko, H.
2018-01-01
Combustible waste fractions of municipal solid waste (MSW) which can not be easily separated or sorted, reused or recycled, may have a high calorifiv value (CV) that can be used in a fuel for energy recovery. The objective of this study was to explore the Refuse Derived Fuel (RDF) potential of municipal solid waste from DKI Jakarta to produce electricity and to promote it to be socially and politically acceptable. For this purpose, 24 sampels of RDF were taken from Bantargebang, cabonized, molded and pressed to be briquette. All samples were analized for moisture, ash, and calorific value in the physical and chemistry Laboratory of ITB Bandung. The analysis of calorific value (CV) shows the CV difference of 1815.8 cal/g between the briquettes (8051.25 cal/g) and the RDF (9867.12 cal/g. The total waste DKI which can be used as briquettes 5253 ton / day or equivalent with 49154115 kWh / day. If the efficiency of electricity production from RDF was 25%, then Jakarta is able to generate electricity from RDF of 12288529 kWh / day or as much as energy needed by 573,480 middle-class households with energy needs of 642.84 kWh/month.
Hemmatjo, Rasoul; Motamedzade, Majid; Aliabadi, Mohsen; Kalatpour, Omid; Farhadian, Maryam
2017-01-01
Background: Firefighters often perform multiple tasks during firefighting operations under unknown and unpredictable conditions in hot and hostile environments. Methods: In this interventional study each firefighters engaged in 4 conditions: namely (1) no cooling device; control (NC), (2) cooling gel (CG), (3) cool vest (CV), and (4) CG+CV. Cooling effects of the employed interventions were evaluated based on heart rate (HR), temporal temperature (TT), reaction time (RT), and the correct response (CR). Results: HR and TT values for use of CG+CV (147.47 bpm [SD 4.8]; 37.88°C [SD 0.20]) and CV bpm (147.53 [SD 4.67]; 37.90°C [SD 0.22]) were significantly lower than the CG (153.67 bpm [SD 4.82]; 38.10°C [SD 0.22]) and NC (154.4 bpm [SD 4.91]; 38.11°C [SD 0.23]) at the end of the activity. RT and CR for use of CG + CV (389.87 ms [SD 6.12]; 143.53 [SD 1.24]) and CV (389.53 ms [SD 6.24]; 143.47 [SD 1.18]) were significantly higher than the CG (385.73 [SD 7.25] ms; 143.07 [SD 0.88]) and NC (385.67 ms [SD 7.19]; 143.00 [SD 0.84]) at the end of the activity. Conclusion: It is concluded that CV was more effective than the CG in attenuating physiological responses and cognitive functions during firefighting operations. Furthermore, combining CV with CG provides no additional benefit. PMID:28326286
Ustundag-Budak, Yasemin; Huysal, Kagan
2017-02-01
Electrolytes have a narrow range of biological variation and small changes are clinically significant. It is important to select the best method for clinical decision making and patient monitoring in the emergency room. The sigma metrics model provides an objective method to evaluate the performance of a method. To calculate sigma metrics for electrolytes measured with one arterial blood gas analyser including two auto-analysers that use different technologies. To identify the best approach for electrolyte monitoring in an emergency setting and the context of routine emergency room workflow. The Coefficient of Variation (CV) was determined from Internal Quality Control (IQC). Data was measured from July 2015 to January 2016 for all three analysers. The records of KBUD external quality data (Association of Clinical Biochemists, Istanbul, Turkey) for both Mindray BS-2000M analyser (Mindray, Shenzhen, China) and Architect C16000 (Abbott Diagnostics, Abbott Park, IL) and MLE clinical laboratory evaluation program (Washington, DC, USA) for Radiometer ABL 700 (Radiometer Trading, Copenhagen, Denmark) during the study period were used to determine the bias. The calculated average sigma values for sodium (-1.1), potassium (3.3), and chloride (0.06) were with the Radiometer ABL700. All calculated sigma values were better than the auto-analysers. The sigma values obtained from all analysers suggest that running more controls and increasing the calibration frequency for electrolytes is necessary for quality assurance.
Smith, Heather F.
2011-01-01
The means by which various microevolutionary processes have acted in the past to produce patterns of cranial variation that characterize modern humans is not thoroughly understood. Applying a microevolutionary framework, within- and among-population variance/covariance (V/CV) structure was compared for several functional and developmental modules of the skull across a worldwide sample of modern humans. V/CV patterns in the basicranium, temporal bone, and face are proportional within and among groups, which is consistent with a hypothesis of neutral evolution; however, mandibular morphology deviated from this pattern. Degree of intergroup similarity in facial, temporal bone, and mandibular morphology is significantly correlated with geographic distance; however, much of the variance remains unexplained. These findings provide insight into the evolutionary history of modern human cranial variation by identifying signatures of genetic drift, gene flow, and migration and set the stage for inferences regarding selective pressures that early humans encountered since their initial migrations around the world. PMID:21461369
Home, automated office, and conventional office blood pressure as predictors of cardiovascular risk.
Andreadis, Emmanuel A; Papademetriou, Vasilios; Geladari, Charalampia V; Kolyvas, George N; Angelopoulos, Epameinondas T; Aronis, Konstantinos N
2017-03-01
Automated office blood pressure (AOBP) has recently been shown to closely predict cardiovascular (CV) events in the elderly. Home blood pressure (HBP) has also been accepted as a valuable method in the prediction of CV disease. This study aimed to compare conventional office BP (OBP), HBP, and AOBP in order to evaluate their value in predicting CV events and deaths in hypertensives. We assessed 236 initially treatment naïve hypertensives, examined between 2009 and 2013. The end points were any CV and non-CV event including mortality, myocardial infarction, coronary heart disease, hospitalization for heart failure, severe arrhythmia, stroke, and intermittent claudication. We fitted proportional hazards models using the different modalities as predictors and evaluated their predictive performance using three metrics: time-dependent receiver operating characteristics curves, the Akaike's Information Criterion, and Harrell's C-index. After a mean follow-up of 7 years, 23 participants (39% women) had experienced ≥1 CV event. Conventional office systolic (hazard ratio [HR] per 1 mm Hg increase in BP, 1.028; 95% confidence interval [CI], 1.009-1.048), automated office systolic (HR per 1 mm Hg increase in BP, 1.031; 95% CI, 1.008-1.054), and home systolic (HR, 1.025; 95% CI, 1.003-1.047) were predictive of CV events. All systolic BP measurements were predictive after adjustment for other CV risk factors (P < .05). The predictive performance of the different modalities was similar. Conventional OBP was significantly higher than AOBP and average HBP. AOBP predicts equally well to OBP and HBP CV events. It appears to be comparable to HBP in the assessment of CV risk, and therefore, its introduction into guidelines and clinical practice as the reference method for assessing BP in the office seems reasonable after verification of these findings by randomized trials. Copyright © 2017 American Society of Hypertension. All rights reserved.
Schulz, S; Seitter, L; Werdan, K; Hofmann, B; Schaller, H-G; Schlitt, A; Reichert, S
2018-05-06
Biological plausibility of an association between severe periodontitis and cardiovascular disease (CVD) has been proven. Genetic characteristics play an important role in both complex inflammatory diseases. Polymorphisms (single nucleotide polymorphisms [SNPs]) in the long noncoding RNA, antisense noncoding RNA in the INK4 locus (ANRIL), were shown to play a leading role in both diseases. The primary objectives of the study were to assess, among cardiovascular (CV angiographically proven ≥50% stenosis of a main coronary artery) patients, the impact of ANRIL SNPs rs133049 and rs3217992 on the severity of periodontitis and the previous history of coronary events, as well as on the occurrence of further adverse CV events. The prevalence of severe periodontitis was analyzed in 1002 CV patients. ANRIL SNPs rs133049 and rs3217992 were genotyped. The prognostic value of both ANRIL SNPs for combined CV endpoint (stroke/transient ischemic attack [TIA], myocardial infarction, death from a CV-related event, death from stroke) was evaluated after a 3-year follow-up period. Hazard ratios (HRs) were adjusted for established CV risk factors applying Cox regression. ANRIL SNPs rs133049 and rs3217992 were not associated with severe periodontitis or history of CVD in CV patients. In the Kaplan-Meier survival curve including the log rank-test (P = .036) and Cox regression (hazard ratio = 1.684, P = .009) the AA genotype of rs3217992 was shown to be an independent predictor for adverse CV events after 3 years of follow-up. SNPs in ANRIL are not risk modulators for severe periodontitis and history of CVD in CV patients. The AA genotype of ANRIL SNPs rs3217992 possesses prognostic power for further CV events within 3 years of follow-up. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Oh, Hyung Jung; Lee, Mi Jung; Lee, Hye Sun; Park, Jung Tak; Han, Seung Hyeok; Yoo, Tae-Hyun; Kim, Yong-Lim; Kim, Yon Su; Yang, Chul Woo; Kim, Nam-Ho; Kang, Shin-Wook
2014-01-01
Abstract Numerous studies have demonstrated that cardiac biomarkers are significant predictors of cardiovascular (CV) and all-cause mortality in ESRD patients, but most of the studies were retrospective or included small numbers of patients, only prevalent dialysis patients, or measured 1 or 2 biomarkers. This study was to analyze the association between 3 cardiac biomarkers and mortality in incident HD patients. A prospective cohort of 864 incident HD patients was followed for 30 months. Based on the median values of baseline NT-proBNP, cTnT, and hsCRP, the patients were divided into “high” and “low” groups, and CV and all-cause mortality were compared between each group. Additionally, time-dependent ROC curves were constructed, and the NRI and IDI of the models with various biomarkers were calculated. The CV survival rates were significantly lower in the “high” NT-proBNP and cTnT groups compared to the corresponding “low” groups, while there was no significant difference in CV survival rate between the 2 hsCRP groups. However, all-cause mortality rates were significantly higher in all 3 “high” groups compared to each lower group. In multivariate analyses, only Ln NT-proBNP was found to be an independent predictor of mortality. Moreover, NT-proBNP was a more prognostic marker for mortality compared to cTnT. In conclusion, NT-proBNP is the biomarker that results in the most added prognostic value on top of traditional risk factors for CV and all-cause mortality in incident HD patients. PMID:25501091
Thurman, Andrea Ries; Yousefieh, Nazita; Chandra, Neelima; Kimble, Thomas; Asin, Susana; Rollenhagen, Christiane; Anderson, Sharon M; Herold, Betsy C; Freiermuth, Jamie L; Starkman, Brian S; Mesquita, Pedro M M; Richardson-Harman, Nicola; Cunningham, Tina; Hillier, Sharon; Rabe, Lorna; Schwartz, Jill L; Doncel, Gustavo F
2017-08-01
The objective of this study was to characterize cervicovaginal (CV) mucosal factors modulating susceptibility to human immunodeficiency virus (HIV) acquisition in healthy premenopausal (PRE) and postmenopausal (POST) women before and after treatment with estradiol (E2). We compared CV mucosal epithelial histology and immune cells, vaginal microbiota, antimicrobial activity of and soluble mucosal protein concentrations in the CV fluid lavage (CVL), and p24 antigen production after ex vivo infection of ectocervical tissues with HIV-1 BaL among PRE women (n = 20) in the follicular and luteal phases of the menstrual cycle and POST women (n = 17) at baseline and after ∼1 month of treatment with 0.01% vaginal E2 cream. Compared to PRE women, we measured higher levels of p24 antigen after ex vivo infection in tissues from POST women. POST women had a significantly thinner vaginal epithelium with decreased tight junction proteins and a higher density of mucosal immune T cells and lower levels of CD1a antigen-presenting cells, antimicrobial peptides, and inflammatory cytokines in the CVL (p values <.05). POST women had higher vaginal pH and lower vaginal Lactobacilli (p values <.05) than PRE women. After vaginal E2 therapy, CV endpoints and ex vivo HIV replication in POST tissues were similar to those observed in PRE tissues. The CV mucosa in POST women is thinned and compromised, with increased HIV-target immune cells and decreased antimicrobial factors, being more susceptible to HIV infection. After POST women receive topical E2 treatment, mucosal endpoints are similar to PRE levels.
Stability enhanced, repeatability improved Parylene-C passivated on QCM sensor for aPTT measurement.
Yang, Yuchen; Zhang, Wei; Guo, Zhen; Zhang, Zhiqi; Zhu, Hongnan; Yan, Ruhong; Zhou, Lianqun
2017-12-15
Determination of blood clotting time is essential in monitoring therapeutic anticoagulants. In this work, Parylene-C passivated on quartz crystal microbalance (P-QCM) was developed for the activated partial thromboplastin time (aPTT) measurement. Compared with typical QCM, P-QCM possessed a hydrophobic surface and sensitive frequency response to viscoelastic variations on electrode surface. Fibrin could be adsorbed effectively, due to the hydrophobicity of the P-QCM surface. Comparing with typical QCM, the peak-to-peak value (PPV) of P-QCM was increased by 1.94% ± 0.63%, which indicated enhancement of signal-to-noise ratio. For P-QCM, the coefficient of variation (CV) of frequency decrease and aPTT were 2.58% and 1.24% separately, which demonstrated improvement of stability and reproducibility. Moreover, compared with SYSMEX CS 2000i haematology analyzer, clinical coefficient index (R 2 ) was 0.983. In conclusion, P-QCM exhibited potential for improving stability, reproducibility and linearity of piezoelectric sensors, and might be more promising for point of care testing (POCT) applications. Copyright © 2017 Elsevier B.V. All rights reserved.
On the Reproducibility of Label-Free Quantitative Cross-Linking/Mass Spectrometry
NASA Astrophysics Data System (ADS)
Müller, Fränze; Fischer, Lutz; Chen, Zhuo Angel; Auchynnikava, Tania; Rappsilber, Juri
2018-02-01
Quantitative cross-linking/mass spectrometry (QCLMS) is an emerging approach to study conformational changes of proteins and multi-subunit complexes. Distinguishing protein conformations requires reproducibly identifying and quantifying cross-linked peptides. Here we analyzed the variation between multiple cross-linking reactions using bis[sulfosuccinimidyl] suberate (BS3)-cross-linked human serum albumin (HSA) and evaluated how reproducible cross-linked peptides can be identified and quantified by LC-MS analysis. To make QCLMS accessible to a broader research community, we developed a workflow that integrates the established software tools MaxQuant for spectra preprocessing, Xi for cross-linked peptide identification, and finally Skyline for quantification (MS1 filtering). Out of the 221 unique residue pairs identified in our sample, 124 were subsequently quantified across 10 analyses with coefficient of variation (CV) values of 14% (injection replica) and 32% (reaction replica). Thus our results demonstrate that the reproducibility of QCLMS is in line with the reproducibility of general quantitative proteomics and we establish a robust workflow for MS1-based quantitation of cross-linked peptides.
Genre, Fernanda; Castañeda, Santos; González-Juanatey, Carlos; Llorca, Javier; Corrales, Alfonso; Miranda-Filloy, José A.; Rueda-Gotor, Javier; Gómez-Vaquero, Carmen; Rodríguez-Rodríguez, Luis; Fernández-Gutiérrez, Benjamín; Pascual-Salcedo, Dora; Balsa, Alejandro; López-Longo, Francisco J.; Carreira, Patricia; Blanco, Ricardo; González-Álvaro, Isidoro; Martín, Javier; González-Gay, Miguel A.
2013-01-01
Rheumatoid arthritis (RA) is a complex polygenic inflammatory disease associated with accelerated atherosclerosis and increased risk of cardiovascular (CV) disease. Previous genome-wide association studies have described SMAD3 rs17228212 polymorphism as an important signal associated with CV events. The aim of the present study was to evaluate for the first time the relationship between this gene polymorphism and the susceptibility to CV manifestations and its potential association with the presence of subclinical atherosclerosis assessed by the evaluation of carotid intima-media thickness (cIMT) in patients with RA. Methods One thousand eight hundred and ninety-seven patients fulfilling classification criteria for RA were genotyped for SMAD3 rs17228212 gene polymorphism through TaqMan genotyping assay. Also, subclinical atherosclerosis determined by the assessment of cIMT was analyzed in a subgroup of these patients by carotid ultrasonography. Results No statistically significant differences were observed when allele frequencies of RA patients with or without CV events were compared. Nevertheless, when RA patients were stratified according to anti-cyclic citrullinated peptide (anti-CCP) status, we found that in RA patients who were negative for anti-CCP antibodies, the presence of C allele of SMAD3 rs17228212 polymorphism conferred a protective effect against the risk of cerebrovascular accident (CVA) after adjustment for demographic and classic CV risk factors (HR [95%CI]=0.36 [0.14–0.94], p=0.038) in a Cox regression model. Additionally, correlation between the presence of C allele of SMAD3 rs17228212 polymorphism and lower values of cIMT was found after adjustment for demographic and classic CV risk factors (p-value=0.0094) in the anti-CCP negative RA patients. Conclusions Our results revealed that SMAD3 rs17228212 gene variant is associated with lower risk of CVA and less severe subclinical atherosclerosis in RA patients negative for anti-CCP antibodies. These findings may have importance to establish predictive models of CV disease in RA patients according to anti-CCP status. PMID:24204921
García-Bermúdez, Mercedes; López-Mejías, Raquel; Genre, Fernanda; Castañeda, Santos; González-Juanatey, Carlos; Llorca, Javier; Corrales, Alfonso; Miranda-Filloy, José A; Rueda-Gotor, Javier; Gómez-Vaquero, Carmen; Rodríguez-Rodríguez, Luis; Fernández-Gutiérrez, Benjamín; Pascual-Salcedo, Dora; Balsa, Alejandro; López-Longo, Francisco J; Carreira, Patricia; Blanco, Ricardo; González-Álvaro, Isidoro; Martín, Javier; González-Gay, Miguel A
2013-01-01
Rheumatoid arthritis (RA) is a complex polygenic inflammatory disease associated with accelerated atherosclerosis and increased risk of cardiovascular (CV) disease. Previous genome-wide association studies have described SMAD3 rs17228212 polymorphism as an important signal associated with CV events. The aim of the present study was to evaluate for the first time the relationship between this gene polymorphism and the susceptibility to CV manifestations and its potential association with the presence of subclinical atherosclerosis assessed by the evaluation of carotid intima-media thickness (cIMT) in patients with RA. One thousand eight hundred and ninety-seven patients fulfilling classification criteria for RA were genotyped for SMAD3 rs17228212 gene polymorphism through TaqMan genotyping assay. Also, subclinical atherosclerosis determined by the assessment of cIMT was analyzed in a subgroup of these patients by carotid ultrasonography. No statistically significant differences were observed when allele frequencies of RA patients with or without CV events were compared. Nevertheless, when RA patients were stratified according to anti-cyclic citrullinated peptide (anti-CCP) status, we found that in RA patients who were negative for anti-CCP antibodies, the presence of C allele of SMAD3 rs17228212 polymorphism conferred a protective effect against the risk of cerebrovascular accident (CVA) after adjustment for demographic and classic CV risk factors (HR [95%CI]=0.36 [0.14-0.94], p=0.038) in a Cox regression model. Additionally, correlation between the presence of C allele of SMAD3 rs17228212 polymorphism and lower values of cIMT was found after adjustment for demographic and classic CV risk factors (p-value=0.0094) in the anti-CCP negative RA patients. Our results revealed that SMAD3 rs17228212 gene variant is associated with lower risk of CVA and less severe subclinical atherosclerosis in RA patients negative for anti-CCP antibodies. These findings may have importance to establish predictive models of CV disease in RA patients according to anti-CCP status.
Cheong, Kee C; Ghazali, Sumarni M; Hock, Lim K; Yusoff, Ahmad F; Selvarajah, Sharmini; Haniff, Jamaiyah; Zainuddin, Ahmad Ali; Ying, Chan Y; Lin, Khor G; Rahman, Jamalludin A; Shahar, Suzana; Mustafa, Amal N
2014-01-01
Previous studies have proposed the lower waist circumference (WC) cutoffs be used for defining abdominal obesity in Asian populations. To determine the optimal cut-offs of waist circumference (WC) in predicting cardiovascular (CV) risk factors in the multi-ethnic Malaysian population. We analysed data from 32,703 respondents (14,980 men and 17,723 women) aged 18 years and above who participated in the Third National Health and Morbidity Survey in 2006. Gender-specific logistic regression analyses were used to examine associations between WC and three CV risk factors (diabetes mellitus, hypertension, and hypercholesterolemia). The Receiver Operating Characteristic (ROC) curves were used to determine the cut-off values of WC with optimum sensitivity and specificity for detecting these CV risk factors. The odds ratio for having diabetes mellitus, hypertension, and hypercholesterolemia, or at least one of these risks, increased significantly as the WC cut-off point increased. Optimal WC cut-off values for predicting the presence of diabetes mellitus, hypertension, hypercholesterolemia and at least one of the three CV risk factors varied from 81.4 to 85.5 cm for men and 79.8 to 80.7 cm for women. Our findings indicate that WC cut-offs of 81 cm for men and 80 cm for women are appropriate for defining abdominal obesity and for recommendation to undergo cardiovascular risk screening and weight management in the Malaysian adult population. © 2014 Asian Oceanian Association for the Study of Obesity . Published by Elsevier Ltd. All rights reserved.
Hansen, Michael J.; Schorfhaar, Richard G.; Peck, James W.; Selgeby, James H.; Taylor, William W.
1995-01-01
Self-sustaining populations of lake trout Salvelinus namaycush have returned to most areas in Lake Superior, but progress toward achieving historic commercial yields has been difficult to measure because of unrecorded losses to predation by sea lamprey Petromyzon marinus and to fisheries. Consequently, we developed restoration targets (catch per effort, CPE; geometric mean number per kilometer of 114-mm stretch-meaure gill net during 1929-1943, when historic yields were sustained) from linear relationships between CPE in commercial and assessment fisheries in Michigan. Target CPEs for lake trout restoration were higher and less variable than the modern CPEs in all areas. Modern CPEs generally increased during the 1970s and early 1980s but declined during the late 1980s and early 1990s. Modern CPEs were highest in western Michigan from the Keweenaw Peninsula to Marquette (71 to 81% of target CPEs), but coefficients of variation (CV,SD/mean) of mean CPEs were 1.4 to 2.4 times greater than target CVs. Around Munising, the modern CPE was lower (41% of the target CPE), whereas the CV was 1.9 times greater than the target CV. Around Grand Marais, the modern CPE was lowest among all areas (17% of the target CPE), but the CV was nearly the same (1.1 times the target CV). In Whitefish Bay, the modern CPE was only 28% of the target CPE and the CV was 9.0 times greater, though the modern period was based on only the years 1979-1982 and 1984-1985. Further progress in restoration in most areas can be achieved only if fishery managers adequately protect existing stocks of wild fish from sea lamprey predation and fishery exploitation.
Bourgault, Richard; Bewley, J. Derek
2002-01-01
Endo-β-mannanase cDNAs were cloned and characterized from ripening tomato (Lycopersicon esculentum Mill. cv Trust) fruit, which produces an active enzyme, and from the tomato cv Walter, which produces an inactive enzyme. There is a two-nucleotide deletion in the gene from tomato cv Walter, which results in a frame shift and the deletion of four amino acids at the C terminus of the full-length protein. Other cultivars that produce either active or inactive enzyme show the same absence or presence of the two-nucleotide deletion. The endo-β-mannanase enzyme protein was purified and characterized from ripe fruit to ensure that cDNA codes for the enzyme from fruit. Immunoblot analysis demonstrated that non-ripening mutants, which also fail to exhibit endo-β-mannanase activity, do so because they fail to express the protein. In a two-way genetic cross between tomato cvs Walter and Trust, all F1 progeny from both crosses produced fruit with active enzyme, suggesting that this form is dominant and homozygous in tomato cv Trust. Self-pollination of a plant from the heterozygous F1 generation yielded F2 plants that bear fruit with and without active enzyme at a ratio appropriate to Mendelian genetic segregation of alleles. Heterologous expression of the two endo-β-mannanase genes in Escherichia coli resulted in active enzyme being produced from cultures containing the tomato cv Trust gene and inactive enzyme being produced from those containing the tomato cv Walter gene. Site-directed mutagenesis was used to establish key elements in the C terminus of the endo-β-mannanase protein that are essential for full enzyme activity. PMID:12427992
Pérez-Castilla, Alejandro; McMahon, John J; Comfort, Paul; García-Ramos, Amador
2017-07-31
The aims of this study were to compare the reliability and magnitude of jump height between the two standard procedures of analysing force platform data to estimate jump height (take-off velocity [TOV] and flight time [FT]) in the loaded squat jump (SJ) exercise performed with a free-weight barbell and in a Smith machine. Twenty-three collegiate men (age 23.1 ± 3.2 years, body mass 74.7 ± 7.3 kg, height 177.1 ± 7.0 cm) were tested twice for each SJ type (free-weight barbell and Smith machine) with 17, 30, 45, 60, and 75 kg loads. No substantial differences in reliability were observed between the TOV (Coefficient of variation [CV]: 9.88%; Intraclass correlation coefficient [ICC]: 0.82) and FT (CV: 8.68%; ICC: 0.88) procedures (CV ratio: 1.14), while the Smith SJ (CV: 7.74%; ICC: 0.87) revealed a higher reliability than the free-weight SJ (CV: 9.88%; ICC: 0.81) (CV ratio: 1.28). The TOV procedure provided higher magnitudes of jump height than the FT procedure for the loaded Smith machine SJ (systematic bias: 2.64 cm; P<0.05), while no significant differences between the TOV and FT procedures were observed in the free-weight SJ exercise (systematic bias: 0.26 cm; P>0.05). Heteroscedasticity of the errors was observed for the Smith machine SJ (r: 0.177) with increasing differences in favour of the TOV procedure for the trials with lower jump height (i.e. higher external loads). Based on these results the use of a Smith machine in conjunction with the FT more accurately determine jump height during the loaded SJ.
Khatir, Dinah S; Pedersen, Michael; Jespersen, Bente; Buus, Niels H
2014-11-01
Determine the reproducibility of renal artery blood flow (RABF) and blood-oxygenation level dependent (R2 *) in patients with chronic kidney disease (CKD) and healthy controls. RABF and R2 * were measured in 11 CKD patients and 9 controls twice with 1- to 2-week interval. R2 * in the cortex and medulla were determined after breathing atmospheric air and 100% oxygen. Reproducibility was evaluated by coefficients of variation (CV), limits of agreements and intra-class coefficient calculated by variance components by maximum likelihood modeling. Single-kidney RABF (mL/min) for patients was: 170 ± 130 and 186 ± 137, and for controls: 365 ± 119 and 361 ± 107 (P < 0.05 versus patients), for first and second scans, respectively. RABF measurements were reproducible with a CV of 12.9% and 8.3% for patients and controls, respectively. Renal cortical R2 * was: 13.6 ± 0.9 and 13.5 ± 1.2 in patients (CV = 8.0%), and 13.8 ± 1.6 and 14.0 ± 1.5 in controls (CV = 5.6%), while medullary R2 *(s(-1) ) was: 26.9 ± 2.0 and 27.0 ± 4.0 (CV = 8.0%) in patients, and 26.0 ± 2.4 and 26.1 ± 2.1 (CV = 3.6%) in controls, for first and second scans, respectively. In both groups R2 * in medulla decreased after breathing 100% oxygen. The reproducibility was high for both RABF and R2 * in patients and controls, particularly in the cortex. Inhalation of 100% oxygen reduced medullary R2 *. © 2013 Wiley Periodicals, Inc.
[Ability of typical greenery shrubs of Beijing to adsorb and arrest PM2.5 ].
Liang, Dan; Wang, Bin; Wang, Yun-qi; Zhang, Hui-lan; Yang, Song-nan; Li, Ang
2014-09-01
Four typical types of green shrubs of Beijing (Euonymus japonicus, Buxus microphylla, Berberis thunbergii cv. atropurpurea, Taxus cuspidate cv. nana) were selected to study their capacities in adsorbing and arresting PM2.5 using both field observations and air chamber simulations. Concurrently, in order to analyze the pollution characteristics of Beijing in winter and spring, the PM2.5 concentrations of December 2012 to May 2013 were collected. Experimental results showed that: From the gas chamber experiments, the ability to adsorb and arrest PM2.5 was in the order of Berberis thunbergii cv. atropurpurea > Buxus microphylla > Taxus cuspidate cv. nana > Euonymus japonicus, mainly due to the differences in leaf characteristics; Outside measurement results showed that the ability to adsorb and arrest PM2.5 was ranked as Buxus microphylla > Berberis thunbergii cv. atropurpurea > Taxus cuspidate cv. nana > Euonymus japonicus. Chamber simulation and outdoor observation showed that Buxus microphylla and Berberis thunbergii cv. atropurpurea had strong ability to adsorb and arrest PM2.5; Meanwhile, the slight differences between the chamber simulation and outdoor observation results might be related to plant structure. Compared to tree species, the planting condition of shrub species was loose, and it greened quickly; By analyzing the Beijing PM2.5 concentration values in winter and spring, it was found that the PM2.5 concentration was particularly high in the winter of Beijing, and evergreen shrubs maintained the ability to adsorb and arrest PM2.5.
Relationship of Productivity to Species Richness in the Xinjiang Temperate Grassland
2016-01-01
The relationship between species richness (SR) and aboveground net primary productivity (ANPP) is still a central and debated issue in community ecology. Previous studies have often emphasized the relationship of alpha diversity (number of species identity) to the mean ANPP with respect to the SR-ANPP relationship while neglecting the contribution of beta diversity (dissimilarity in species composition) to the mean ANPP and to the stability of ANPP (coefficient of ANPP: CV of ANPP). In this study, we used alpha and beta diversity, mean ANPP and the CV of ANPP collected from 159 sites and belonging to three vegetation types in the Xinjiang temperate grassland to first examine their trends along climatic factors and among different vegetation types and then test the relationship among alpha (beta) diversity and mean ANPP and the CV of ANPP. Our results showed that in the Xinjiang temperate grasslands, alpha diversity was positively and linearly correlated with MAP but unimodally correlated with MAT. Meanwhile, beta diversity was unimodally correlated with MAP but linearly correlated with MAT. Relative to desert steppe, meadow steppe and typical steppe had the highest alpha and beta diversity, respectively. Except for ANPP exhibiting a quadratic relationship with MAP, no significant relationship was found among ANPP, the CV of ANPP and climatic factors. ANPP and the CV of ANPP also exhibited no apparent patterns in variation among different vegetation types. Our results further showed that mean ANPP was closely associated with alpha diversity. Both linear and unimodal relationships were detected between alpha diversity and mean ANPP, but their particular form was texture-dependent. Meanwhile, the CV of ANPP was positively correlated with beta diversity. Our results indicated that in addition to incorporating alpha diversity and mean ANPP, incorporating beta diversity and the CV of ANPP could expand our understanding of the SR-ANPP relationship. PMID:27100676
Ecker, Christine; Ginestet, Cedric; Feng, Yue; Johnston, Patrick; Lombardo, Michael V; Lai, Meng-Chuan; Suckling, John; Palaniyappan, Lena; Daly, Eileen; Murphy, Clodagh M; Williams, Steven C; Bullmore, Edward T; Baron-Cohen, Simon; Brammer, Michael; Murphy, Declan G M
2013-01-01
Neuroimaging studies of brain anatomy in autism spectrum disorder (ASD) have mostly been based on measures of cortical volume (CV). However, CV is a product of 2 distinct parameters, cortical thickness (CT) and surface area (SA), that in turn have distinct genetic and developmental origins. To investigate regional differences in CV, SA, and CT as well as their relationship in a large and well-characterized sample of men with ASD and matched controls. Multicenter case-control design using quantitative magnetic resonance imaging. Medical Research Council UK Autism Imaging Multicentre Study. A total of 168 men, 84 diagnosed as having ASD and 84 controls who did not differ significantly in mean (SD) age (26 [7] years vs 28 [6] years, respectively) or full-scale IQ (110 [14] vs 114 [12], respectively). Between-group differences in CV, SA, and CT investigated using a spatially unbiased vertex-based approach; the degree of spatial overlap between the differences in CT and SA; and their relative contribution to differences in regional CV. Individuals with ASD differed from controls in all 3 parameters. These mainly consisted of significantly increased CT within frontal lobe regions and reduced SA in the orbitofrontal cortex and posterior cingulum. These differences in CT and SA were paralleled by commensurate differences in CV. The spatially distributed patterns for CT and SA were largely nonoverlapping and shared only about 3% of all significantly different locations on the cerebral surface. Individuals with ASD have significant differences in CV, but these may be underpinned by (separable) variations in its 2 components, CT and SA. This is of importance because both measures result from distinct developmental pathways that are likely modulated by different neurobiological mechanisms. This finding may provide novel targets for future studies into the etiology of the condition and a new way to fractionate the disorder.
Optimization of myocardial deformation imaging in term and preterm infants.
Poon, Chuen Y; Edwards, Julie M; Joshi, Suchita; Kotecha, Sailesh; Fraser, Alan G
2011-03-01
Myocardial deformation imaging is now used to assess regional ventricular function in infants but their small size presents particular technical challenges. We therefore investigated the determinants of reproducibility of myocardial longitudinal strain (ε) in term and preterm infants, in order to determine optimal technical settings. Repeated longitudinal ε measurements of the mid-segments of the septum, and the left and right ventricular free walls, were performed using five different computation distances (CDs; also called strain length) in 20 infants. The coefficients of variation (CV) were calculated for each CD. Overall, ε measurements were most reproducible with a CD of 6 mm (CV 11.7%). In preterm infants (<34 weeks gestation; mean ± SD diastolic LV length, 20.3 ± 3.5 mm), ε measurements were most reproducible with CD of 6 mm (CV 7.2%); in term infants (>37 weeks gestation; mean ± SD diastolic LV length, 29.6 ± 3.0 mm), ε measurements were most reproducible with CD of 10 mm (CV 13.2%). The reproducibility of measuring ε increased with higher frame rates, from CV of 17.3% at frame rates <180 per s to 11.7% for frame rates >180 per s and 9.6% for rates >248 per s. In newborn infants, tissue Doppler loops should be acquired at frame rates above 180 per s. Myocardial deformation analysis of preterm infants should be performed using a CD of 6 mm, whereas a CD of 10 mm is more reproducible in term infants.
Concentration fluctuations and dilution in aquifers
NASA Astrophysics Data System (ADS)
Kapoor, Vivek; Kitanidis, Peter K.
1998-05-01
The concentration of solute undergoing advection and local dispersion in a random hydraulic conductivity field is analyzed to quantify its variability and dilution. Detailed numerical evaluations of the concentration variance σc2 are compared to an approximate analytical description, which is based on a characteristic variance residence time (VRT), over which local dispersion destroys concentration fluctuations, and effective dispersion coefficients that quantify solute spreading rates. Key features of the analytical description for a finite size impulse input of solute are (1) initially, the concentration fields become more irregular with time, i.e., coefficient of variation, CV=σc/
Cabo, Candido
2014-01-01
Initiation of cardiac arrhythmias typically follows one or more premature impulses either occurring spontaneously or applied externally. In this study, we characterize the dynamics of propagation of single (S2) and double premature impulses (S3), and the mechanisms of block of premature impulses at structural heterogeneities caused by remodeling of gap junctional conductance (Gj) in infarcted myocardium. Using a sub-cellular computer model of infarcted tissue, we found that |INa,max|, prematurity (coupling interval with the previous impulse), and conduction velocity (CV) of premature impulses change dynamically as they propagate away from the site of initiation. There are fundamental differences between the dynamics of propagation of S2 and S3 premature impulses: for S2 impulses |INa,max| recovers fast, prematurity decreases and CV increases as propagation proceeds; for S3 impulses low values of |INa,max| persist, prematurity could increase, and CV could decrease as impulses propagate away from the site of initiation. As a consequence it is more likely that S3 impulses block at sites of structural heterogeneities causing source/sink mismatch than S2 impulses block. Whether premature impulses block at Gj heterogeneities or not is also determined by the values of Gj (and the space constant λ) in the regions proximal and distal to the heterogeneity: when λ in the direction of propagation increases >40%, premature impulses could block. The maximum slope of CV restitution curves for S2 impulses is larger than for S3 impulses. In conclusion: (1) The dynamics of propagation of premature impulses make more likely that S3 impulses block at sites of structural heterogeneities than S2 impulses block; (2) Structural heterogeneities causing an increase in λ (or CV) of >40% could result in block of premature impulses; (3) A decrease in the maximum slope of CV restitution curves of propagating premature impulses is indicative of an increased potential for block at structural heterogeneities. PMID:25566085
Cabo, Candido
2014-01-01
Initiation of cardiac arrhythmias typically follows one or more premature impulses either occurring spontaneously or applied externally. In this study, we characterize the dynamics of propagation of single (S2) and double premature impulses (S3), and the mechanisms of block of premature impulses at structural heterogeneities caused by remodeling of gap junctional conductance (Gj) in infarcted myocardium. Using a sub-cellular computer model of infarcted tissue, we found that |INa,max|, prematurity (coupling interval with the previous impulse), and conduction velocity (CV) of premature impulses change dynamically as they propagate away from the site of initiation. There are fundamental differences between the dynamics of propagation of S2 and S3 premature impulses: for S2 impulses |INa,max| recovers fast, prematurity decreases and CV increases as propagation proceeds; for S3 impulses low values of |INa,max| persist, prematurity could increase, and CV could decrease as impulses propagate away from the site of initiation. As a consequence it is more likely that S3 impulses block at sites of structural heterogeneities causing source/sink mismatch than S2 impulses block. Whether premature impulses block at Gj heterogeneities or not is also determined by the values of Gj (and the space constant λ) in the regions proximal and distal to the heterogeneity: when λ in the direction of propagation increases >40%, premature impulses could block. The maximum slope of CV restitution curves for S2 impulses is larger than for S3 impulses. (1) The dynamics of propagation of premature impulses make more likely that S3 impulses block at sites of structural heterogeneities than S2 impulses block; (2) Structural heterogeneities causing an increase in λ (or CV) of >40% could result in block of premature impulses; (3) A decrease in the maximum slope of CV restitution curves of propagating premature impulses is indicative of an increased potential for block at structural heterogeneities.
Winter, Randolph L; Saunders, Ashley B; Gordon, Sonya G; Miller, Matthew W; Fosgate, Geoffrey T; Suchodolski, Jan S; Steiner, Jörg M
2017-06-01
Biologic variability (BV) is one aspect of interpreting changes in biomarker concentrations known to be clinically important in people with cardiac disease, but it has not been adequately addressed in dogs so far. The purpose of the study was to determine BV of cardiac troponin I (cTnI) in healthy dogs and dogs with 3 stages of myxomatous mitral valve disease (MMVD). Healthy dogs and dogs with 3 stages of MMVD were prospectively assigned to groups based on comprehensive clinical evaluation using current guidelines. Concentrations of cTnI were measured hourly, daily, and weekly using standard and high-sensitivity immunoassays. Within- (CV I ) and between-subject (CV G ) coefficients of variability, percent reference change value (RCV), and index of individuality (IoI) were calculated. All 10 healthy dogs and 76/112 (68%) of samples from 28 MMVD dogs had cTnI concentrations below the limit of detection (LOD) using a standard sensitivity immunoassay. Only 49/160 (31%) of healthy dog samples and no MMVD samples had cTnI below the high-sensitivity immunoassay LOD. Data analysis for the high-sensitivity immunoassay revealed CV I of 48.1%, CV G of 60.1%, RCV of 134.0%, and IoI of 0.804 in healthy dogs. In MMVD dogs, CV I was 39.6%, CV G was 80.7%, RCV was 110%, and IoI was 0.494. Of all MMVD dogs, those with Stage B2 had the lowest RCV of 91%. Biologic variability affects cTnI concentrations in healthy dogs and dogs with MMVD. Consideration of BV may be clinically relevant when monitoring individual changes in cTnI values, using high-sensitivity immunoassays. © 2017 American Society for Veterinary Clinical Pathology.
Phenolic content and anti-hyperglycemic activity of pecan cultivars from Egypt.
El Hawary, Seham S; Saad, Soumaya; El Halawany, Ali Mahmoud; Ali, Zeinab Y; El Bishbishy, Mahitab
2016-01-01
Pecans are commonly used nuts with important health benefits such as anti-hyperglycemic and anti-hyperlipidemic effects. A comparative investigation of the antihyperglycemic and total phenolic content of the leaves and shells of four pecan cultivars growing in Egypt was carried out. The selected cultivars (cv.) were Carya illinoinensis Wangneh. K. Koch. cv. Wichita, cv. WesternSchely, cv. Cherokee, and cv. Sioux family Juglandaceae. Total phenolic and flavonoid contents of the leaves and shells of pecan cultivars were carried out using Folin-Ciocalteu's and aluminum chloride assays, respectively. Moreover, HPLC profiling of phenolic and flavonoid contents was carried out using RP-HPLC-UV. In addition, in vivo anti-hyperglycemic activity of the ethanolic extracts (125 mg/kg bw, p.o.) of C. illinoinensis cultivars was carried out using streptozotocin (STZ)-induced diabetes in Sprague-Dawley rats for 4 weeks. Phenolic contents were higher in shells than leaves in all studied cultivars, while flavonoids were higher in leaves. Leaves and shells of cv. Sioux showed the highest phenolics (251.7 µg gallic acid equivalent (GAE)/g), and flavonoid contents (103.27 µg rutin equivalent (RE)/g and 210.67 µg quercetin equivalent (QE)/g), respectively. The HPLC profiling of C. illinoinensis cultivars resulted in the identification of eight flavonoids (five of these compounds are identified for the first time from pecan), and 15 phenolic acids (six are identified for the first time from pecan). Leaves of cv. Sioux revealed the most potent decrease in blood glucose and glycated hemoglobin (HbA1c%) (194.9 mg/dl and 6.52%, respectively), among other tested cultivars. Moreover, leaves of cv. Sioux significantly elevated serum total antioxidant capacity (TAC) and reduced glutathione (GSH) (0.33 mMol/l and 30.68 mg/dl, respectively), and significantly suppressed the markers of both lipid peroxidation (malondialdehyde, MDA) and protein oxidation (protein carbonyl, PC) (14.25 µmol/ml and 3.18 nmol/mg protein, respectively). Different pecan cultivars showed significant variation in its phenolic and flavonoid contents and consequently their antioxidant and anti-hyperglycemic effects.
WE-H-207A-04: Impact of Lesion Location On the Repeatability of 18F-NaF PET/CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, C; Perk, T; Harmon, S
Purpose: Quantifying the repeatability of imaging biomarkers is critical for assessing therapeutic response. While {sup 18}F-NaF PET/CT has shown to be a repeatable imaging method, research has not shown which factors may influence its repeatability. The purpose of this study was to evaluate whether the location of the lesion impacts the repeatability of quantitative {sup 18}F-NaF PET-derived SUV metrics. Methods: Metastatic castrate-resistant prostate cancer patients with multiple bone lesions received whole-body test-retest NaF PET/CT scans. Malignant bone lesions of PET-defined volume greater than 1.5 cm{sup 3} were identified by a nuclear medicine physician and automatically delineated using a SUV>15 threshold.more » The maximum (SUVmax), average (SUVmean), and total (SUVtotal) SUV were extracted from each lesion. Atlas-based segmentation was used to divide each patient skeleton into 25 skeletal regions. Test-retest repeatability of each SUV metric was assessed with coefficient of variation (CV). Results: A total of 265 malignant bone lesions from 18 patients were identified by nuclear medicine physician. The largest proportion of bone lesions were localized to the spine (41%), with 41% of those lesions localized to the thoracic spine. One-way ANOVA showed that measurement differences differed significantly for all three metrics across locations (p<0.01 for each metrics). Overall, CV was smallest for SUVmean at 5.3%, followed by SUVmax at 11.5% and SUVtotal at 20.4%. Lesions in the pubis were consistently the most repeatable (CV(SUVmax)= 5.6%, CV(SUVmean)= 0.6%, CV(SUVtotal)= 2.9%). According to SUVmean, repeatability was poorest in the cervical spine (CV = 6.2%), whereas according to SUVmax and SUVtotal, repeatability was poorest in the ribs (CV(SUVmax)= 15.0%, CV(SUVtotal)= 29.8%). Conclusion: Location of the lesion affects the repeatability of {sup 18}F-NaF PET/CT, with the ribs and cervical spine having the lowest repeatability and the pubis having the highest repeatability. These results can be used to establish location-specific response criteria for NaF PET-based treatment response assessment.« less
Sun, Zhenlu; Zhang, Guifang; Guo, Peijun; Liu, Juan; Gao, Qiao; Xu, Xiaowen; Gong, Lianfeng
2017-01-01
ABSTRACT This study aimed to investigate the epidemiological characterizations and pathogen spectrum of hand, foot, and mouth disease (HFMD) in Yantai City, Shandong Province, China, during 2011–2015, and to study the nucleotide evolution and amino acid variation of coxsackievirus A16 (CV-A16) epidemic strains that caused HFMD. The HFMD epidemic began to rise in March, and became prevalent from May to August, reached its peak in June, and then declined in September every year, children aged one to 5 years-old had the highest incidence rate whereas the incidence in children under 6 months was very low, and there were more males than females. Enterovirus nucleic acid detection using real-time reverse transcription polymerase chain reaction was performed on 2130 clinical specimens collected from patients with HFMD between 2011 and 2015, and 2012 enterovirus positive samples were detected, including 678 CV-A16, 639 EV-A71, and 695 other enteroviruses. In total, 60 CV-A16 isolates were randomly selected each year for virus isolation, of which 33 CV-A16 strains were randomly selected for further characterization because CV-A16 is the predominant serotype that caused HFMD in Yantai City, and a phylogenetic tree based on the VP1 region was constructed. All 33 CV-A16 strains belonged to the Bla and B1b genotypes, with a nucleotide similarity of 87.9–100% and deduced amino acid similarity of 98.6–100%. Compared with the reference strain Tainan/5079/98 (AF177911), amino acid mutations were identified at positions 11, 23, 25, 31, 99, 145, and 289, where differences were observed among 33 strains, indicating a unique mutation map of CV-A16 in Yantai City. Our findings demonstrate the etiologic characteristics of HFMD, provide supporting evidence for the prevention and control of HFMD, and open a promising avenue for vaccine development against HFMD, by targeting CV-A16. PMID:28537484
Decision-making under risk in children, adolescents, and young adults.
Paulsen, David J; Platt, Michael L; Huettel, Scott A; Brannon, Elizabeth M
2011-01-01
Adolescents often make risky and impulsive decisions. Such behavior has led to the common assumption that a dysfunction in risk-related decision-making peaks during this age. Differences in how risk has been defined across studies, however, make it difficult to draw conclusions about developmental changes in risky decision-making. Here, we developed a non-symbolic economic decision-making task that can be used across a wide age span and that uses coefficient of variation (CV) in reward as an index of risk. We found that young children showed the strongest preference for risky compared to sure bet options of equal expected value, adolescents were intermediate in their risk preference, and young adults showed the strongest risk aversion. Furthermore, children's preference for the risky option increased for larger CVs, while adolescents and young adults showed the opposite pattern, favoring the sure bet more often as CV increased. Finally, when faced with two gambles in a risk-return tradeoff, all three age groups exhibited a greater preference for the option with the lower risk and return as the disparity in risk between the two options increased. These findings demonstrate clear age-related differences in economic risk preferences that vary with choice set and risk. Importantly, adolescence appears to represent an intermediate decision-making phenotype along the transition from childhood to adulthood, rather than an age of heightened preference for economic risk.
Kim, Nam-Gun; Kim, Myeong-Ae; Park, Young-Il; Jung, Tae-Sung; Son, Seong-Wan; So, ByungJae
2015-01-01
Monoclonal anti-enrofloxacin antibody was prepared for a direct competitive enzyme-linked immunosorbent assay (ELISA) and purification system using monoclonal antibody (mAb) coupled magnetic nanoparticles (MNPs). The IC50 values of the developed mAb for enrofloxacin (ENR), ciprofloxacin, difloxacin, sarafloxacin, pefloxacin, and norfloxacin were 5.0, 8.3, 9.7, 21.7, 36.0, and 63.7 ng/mL, respectively. The lowest detectable level of ENR was 0.7 ng/mL in the prepared ELISA system. To validate the developed ELISA in the food matrix, known amounts of ENR were spiked in meat and egg samples at 10, 20 and 30 ng/mL. Recoveries for ENR ranged from 72.9 to 113.16% with a coefficient of variation (CV) of 2.42 to 10.11%. The applicability of the mAb-MNP system was verified by testing the recoveries for ENR residue in three different matrices. Recoveries for ENR ranged from 75.16 to 86.36%, while the CV ranged from 5.08 to 11.53%. Overall, ENR-specific monoclonal antibody was prepared and developed for use in competitive to ELISAs for the detection of ENR in animal meat samples. Furthermore, we suggest that a purification system for ENR using mAb-coupled MNPs could be useful for determination of ENR residue in food. PMID:26040610
Decision-Making Under Risk in Children, Adolescents, and Young Adults
Paulsen, David J.; Platt, Michael L.; Huettel, Scott A.; Brannon, Elizabeth M.
2011-01-01
Adolescents often make risky and impulsive decisions. Such behavior has led to the common assumption that a dysfunction in risk-related decision-making peaks during this age. Differences in how risk has been defined across studies, however, make it difficult to draw conclusions about developmental changes in risky decision-making. Here, we developed a non-symbolic economic decision-making task that can be used across a wide age span and that uses coefficient of variation (CV) in reward as an index of risk. We found that young children showed the strongest preference for risky compared to sure bet options of equal expected value, adolescents were intermediate in their risk preference, and young adults showed the strongest risk aversion. Furthermore, children's preference for the risky option increased for larger CVs, while adolescents and young adults showed the opposite pattern, favoring the sure bet more often as CV increased. Finally, when faced with two gambles in a risk–return tradeoff, all three age groups exhibited a greater preference for the option with the lower risk and return as the disparity in risk between the two options increased. These findings demonstrate clear age-related differences in economic risk preferences that vary with choice set and risk. Importantly, adolescence appears to represent an intermediate decision-making phenotype along the transition from childhood to adulthood, rather than an age of heightened preference for economic risk. PMID:21687443
Liu, Kailin; Xu, Shiji; Zhang, Minghuan; Kou, Yahong; Zhou, Xiaomao; Luo, Kun; Hu, Lifeng; Liu, Xiangying; Liu, Min; Bai, Lianyang
2016-01-01
The toxicity of ionizable organic compounds to organisms depends on the pH, which therefore affects risk assessments of these compounds. However, there is not a direct chemical method to predict the toxicity of ionizable organic compounds. To determine whether hollow-fiber liquid-phase microextraction (HF-LPME) is applicable for this purpose, a three-phase HF-LPME was used to measure sulfadiazine and estimate its toxicity to Daphnia magna in solutions of different pH. The result indicated that the sulfadiazine concentrations measured by HF-LPME decreased with increasing pH, which is consistent with the decreased toxicity. The concentration immobilize 50% of the daphnids (EC50) in 48 h calculated from nominal concentrations increased from 11.93 to 273.5 mg L−1 as the pH increased from 6.0 to 8.5, and the coefficient of variation (CV) of the EC50 values reached 104.6%. When calculated from the concentrations measured by HF-LPME (pH 12 acceptor phase), the EC50 ranged from 223.4 to 394.6 mg L−1, and the CV decreased to 27.60%, suggesting that the concentrations measured by HF-LPME can be used to estimate the toxicity of sulfadiazine irrespective of the solution pH. PMID:28004779
Prezzi, D; Goh, V; Virdi, S; Mallett, S; Grierson, C; Breen, D J
2017-01-01
To determine the effect of Adaptive Statistical Iterative Reconstruction (ASIR) on perfusion CT (pCT) parameter quantitation and image quality in primary colorectal cancer. Prospective observational study. Following institutional review board approval and informed consent, 32 patients with colorectal adenocarcinoma underwent pCT (100 kV, 150 mA, 120 s acquisition, axial mode). Tumour regional blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) were determined using identical regions-of-interests for ASIR percentages of 0%, 20%, 40%, 60%, 80% and 100%. Image noise, contrast-to-noise ratio (CNR) and pCT parameters were assessed across ASIR percentages. Coefficients of variation (CV), repeated measures analysis of variance (rANOVA) and Spearman' rank order correlation were performed with statistical significance at 5%. With increasing ASIR percentages, image noise decreased by 33% while CNR increased by 61%; peak tumour CNR was greater than 1.5 with 60% ASIR and above. Mean BF, BV, MTT and PS differed by less than 1.8%, 2.9%, 2.5% and 2.6% across ASIR percentages. CV were 4.9%, 4.2%, 3.3% and 7.9%; rANOVA P values: 0.85, 0.62, 0.02 and 0.81 respectively. ASIR improves image noise and CNR without altering pCT parameters substantially.
Shapira, Gali; Yodfat, Ofer; HaCohen, Arava; Feigin, Paul; Rubin, Richard
2010-01-01
Background Optimal continuous subcutaneous insulin infusion (CSII) therapy emphasizes the relationship between insulin dose and carbohydrate consumption. One widely used tool (bolus calculator) requires the user to enter discrete carbohydrate values; however, many patients might not estimate carbohydrates accurately. This study assessed carbohydrate estimation accuracy in type 1 diabetes CSII users and compared simulated blood glucose (BG) outcomes using the bolus calculator and the “bolus guide,” an alternative system based on ranges of carbohydrate load. Methods Patients (n = 60) estimated the carbohydrate load of a representative sample of meals of known carbohydrate value. The estimated error distribution [coefficient of variation (CV)] was the basis for a computer simulation (n = 1.6 million observations) of insulin recommendations for the bolus guide and bolus calculator, translated into outcome blood glucose (OBG) ranges (≤60, 61–200, >201 mg/dl). Patients (n = 30) completed questionnaires assessing satisfaction with the bolus guide. Results The CV of typical meals ranged from 27.9% to 44.5%. The percentage of simulated OBG for the calculator and the bolus guide in the <60 mg/dl range were 20.8% and 17.2%, respectively, and 13.8% and 15.8%, respectively, in the >200 mg/dl range. The mean and median scores of all bolus guide satisfaction items and ease of learning and use were 4.17 and 4.2, respectively (of 5.0). Conclusion The bolus guide recommendation based on carbohydrate range selection is substantially similar to the calculator based on carbohydrate point estimation and appears to be highly accepted by type 1 diabetes insulin pump users. PMID:20663453
Estimation of intra-operator variability in perfusion parameter measurements using DCE-US
Gauthier, Marianne; Leguerney, Ingrid; Thalmensi, Jessie; Chebil, Mohamed; Parisot, Sarah; Peronneau, Pierre; Roche, Alain; Lassau, Nathalie
2011-01-01
AIM: To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue®. METHODS: The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue® (Bracco, Milan, Italy) and using a Toshiba Aplio® ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging (“Vascular Recognition Imaging”) involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV). RESULTS: In vitro, different volumes of SonoVue® were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%. CONCLUSION: AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values. PMID:21512654
Estimation of intra-operator variability in perfusion parameter measurements using DCE-US.
Gauthier, Marianne; Leguerney, Ingrid; Thalmensi, Jessie; Chebil, Mohamed; Parisot, Sarah; Peronneau, Pierre; Roche, Alain; Lassau, Nathalie
2011-03-28
To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue(®). The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue(®) (Bracco, Milan, Italy) and using a Toshiba Aplio(®) ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging ("Vascular Recognition Imaging") involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV). In vitro, different volumes of SonoVue(®) were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%. AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values.
Takahara, Mitsuyoshi; Shiraiwa, Toshihiko; Kaneto, Hideaki; Katakami, Naoto; Matsuoka, Taka-Aki; Shimomura, Iichiro
2012-01-01
We retrospectively investigated the effect of adding dipeptidyl peptidase-4 (DPP-4) inhibitor and tapering sulfonylurea on blood glucose fluctuation in Asian patients with type 2 diabetes mellitus under basal-supported oral therapy (BOT). We recruited twenty-two consecutive Japanese patients with type 2 diabetes mellitus who had blood glucose fluctuation under the combination therapy of insulin glargine and glimepiride and had sitagliptin initiated with glimepiride tapared. Their hemoglobin A1c levels and mean blood glucose profiles of seven points in self-monitoring blood glucose (SMBG) were 7.4 ± 0.6% and 8.6 ± 2.0 mmol/L, respectively. Sitagliptin was initiated with the dose of 50 mg per day and titrated up to 100 mg per day when necessary. Glimepiride was withdrawn if possible. Blood glucose fluctuation was evaluated with SMBG by calculating M-value, its range (the difference of maximum and minimum blood glucose levels), and its coefficient of variation (CV). Two months after sitagliptin add-on, M-value was decreased from 19 ± 13 to 13 ± 8 (p = 0.04). Blood glucose range and CV were also improved from 9.6 ± 2.9 mmol/L to 7.9 ± 2.6 mmol/L (p = 0.01), and from 33 ± 8% to 29 ± 8% (p < 0.01), respectively. Hemoglobin A1c levels and mean blood glucose profiles were unchanged (p = 0.93 and 0.47). In conclusion, blood glucose fluctuation was significantly improved two months after adding sitagliptin and tapering glimepiride in type 2 diabetic Japanese patients who were treated by BOT with insulin glargine and glimepiride.
Kusunose, Kenya; Shibayama, Kentaro; Iwano, Hiroyuki; Izumo, Masaki; Kagiyama, Nobuyuki; Kurosawa, Koji; Mihara, Hirotsugu; Oe, Hiroki; Onishi, Tetsuari; Onishi, Toshinari; Ota, Mitsuhiko; Sasaki, Shunsuke; Shiina, Yumi; Tsuruta, Hikaru; Tanaka, Hidekazu
2018-07-01
Visual estimation of left ventricular ejection fraction (LVEF) is widely applied to confirm quantitative EF. However, visual assessment is subjective, and variability may be influenced by observer experience. We hypothesized that a learning session might reduce the misclassification rate. Protocol 1: Visual LVEFs for 30 cases were measured by 79 readers from 13 cardiovascular tertiary care centers. Readers were divided into 3 groups by their experience: limited (1-5 years, n=28), intermediate (6-11 years, n=26), and highly experienced (12-years, n=25). Protocol 2: All readers were randomized to assess the effect of a learning session with reference images only or feedback plus reference images. After the session, 20 new cases were shown to all readers following the same methodology. To assess the concordance and accuracy pre- and post-intervention, each visual LVEF measurement was compared to overall average values as a reference. Experience affected the concordance in visual EF values among the readers. Groups with intermediate and high experience showed significantly better mean difference (MD), standard deviation (SD), and coefficient of variation (CV) than those with limited experience at baseline. The learning session with reference image reduced the MD, SD, and CV in readers with limited experience. The learning session with reference images plus feedback also reduced proportional bias. Importantly, the misclassification rate for mid-range EF cases was reduced regardless of experience. This large multicenter study suggested that a simple learning session with reference images can successfully reduce the misclassification rate for LVEF assessment. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Duan; Li, Xiaoli; Hagihira, Satoshi; Sleigh, Jamie W.
2011-10-01
Bicoherence quantifies the degree of quadratic phase coupling among different frequency components within a signal. Previous studies, using Fourier-based methods of bicoherence calculation (FBIC), have demonstrated that electroencephalographic bicoherence can be related to the end-tidal concentration of inhaled anesthetic drugs. However, FBIC methods require excessively long sections of the encephalogram. This problem might be overcome by the use of wavelet-based methods. In this study, we compare FBIC and a recently developed wavelet bicoherence (WBIC) method as a tool to quantify the effect of isoflurane on the electroencephalogram. We analyzed a set of previously published electroencephalographic data, obtained from 29 patients who underwent elective abdominal surgery under isoflurane general anesthesia combined with epidural anesthesia. Nine potential indices of the electroencephalographic anesthetic effect were obtained from the WBIC and FBIC techniques. The relationship between each index and end-tidal concentrations of isoflurane was evaluated using correlation coefficients (r), the inter-individual variations (CV) of index values, the coefficient of determination (R2) of the PKPD models and the prediction probability (PK). The WBIC-based indices tracked anesthetic effects better than the traditional FBIC-based ones. The DiagBic_En index (derived from the Shannon entropy of the diagonal bicoherence values) performed best [r = 0.79 (0.66-0.92), CV = 0.08 (0.05-0.12), R2 = 0.80 (0.75-0.85), PK = 0.79 (0.75-0.83)]. Short data segments of ~10-30 s were sufficient to reliably calculate the indices of WBIC. The wavelet-based bicoherence has advantages over the traditional Fourier-based bicoherence in analyzing volatile anesthetic effects on the electroencephalogram.
Tentolouris, Nikolaos; Kanellos, Panagiotis T; Siami, Evangelia; Athanasopoulou, Elpida; Chaviaras, Nikolaos; Kolovou, Genovefa; Sfikakis, Petros P; Katsilambros, Nikolaos
2017-08-01
Lipotest ® is a standardized fat-rich meal designed for use as a test meal during a fat tolerance test (FTT) for the study of postprandial triacylglycerol (TAG) concentrations. Herein we examined the precision and reproducibility of examination using Lipotest ® on postprandial TAG levels. A total of 26 healthy consenting subjects were examined twice after 8-10 h fasting with an interval of approximately 1 week apart. Blood samples were collected at baseline and 1, 2, 3, and 4 h after consumption of the test meal for measurement of plasma total TAG levels. We examined agreement, precision, and accuracy between the two visits using the Altman plots and correlation coefficient. Reproducibility was tested using the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Moreover, the area under the curve (AUC) as a summary measure of the overall postprandial TAG levels was calculated. The agreement, precision (r ≥ 0.74, p < 0.001), and accuracy (≥0.99) between the measurements in plasma TAG during Lipotest ® testing in the two visits were high. In terms of reproducibility, the values of CV were 15.59-23.83% while those of ICC were ≥0.75. The values of the AUCs in the visits were not different (p = 0.87). A single measurement of plasma TAG levels at 4 h after Lipotest ® consumption depicted peak postprandial TAG concentration. A FTT using Lipotest ® as a standardized meal has good precision and reproducibility for the study of postprandial TAG levels in healthy individuals. A single determination of plasma TAG concentration at 4 h after Lipotest ® consumption captures peak postprandial TAG response.
Increased ventilatory variability and complexity in patients with hyperventilation disorder.
Bokov, Plamen; Fiamma, Marie-Noëlle; Chevalier-Bidaud, Brigitte; Chenivesse, Cécile; Straus, Christian; Similowski, Thomas; Delclaux, Christophe
2016-05-15
It has been hypothesized that hyperventilation disorders could be characterized by an abnormal ventilatory control leading to enhanced variability of resting ventilation. The variability of tidal volume (VT) often depicts a nonnormal distribution that can be described by the negative slope characterizing augmented breaths formed by the relationship between the probability density distribution of VT and VT on a log-log scale. The objectives of this study were to describe the variability of resting ventilation [coefficient of variation (CV) of VT and slope], the stability in respiratory control (loop, controller and plant gains characterizing ventilatory-chemoresponsiveness interactions) and the chaotic-like dynamics (embedding dimension, Kappa values characterizing complexity) of resting ventilation in patients with a well-defined dysfunctional breathing pattern characterized by air hunger and constantly decreased PaCO2 during a cardiopulmonary exercise test. Compared with 14 healthy subjects with similar anthropometrics, 23 patients with hyperventilation were characterized by increased variability of resting tidal ventilation (CV of VT median [interquartile]: 26% [19-35] vs. 36% [28-48], P = 0.020; slope: -6.63 [-7.65; -5.36] vs. -3.88 [-5.91; -2.66], P = 0.004) that was not related to increased chemical drive (loop gain: 0.051 [0.039-0.221] vs. 0.044 [0.012-0.087], P = 0.149) but that was related to an increased ventilatory complexity (Kappa values, P < 0.05). Plant gain was decreased in patients and correlated with complexity (with Kappa 5 - degree 5: Rho = -0.48, P = 0.006). In conclusion, well-defined patients suffering from hyperventilation disorder are characterized by increased variability of their resting ventilation due to increased ventilatory complexity with stable ventilatory-chemoresponsiveness interactions. Copyright © 2016 the American Physiological Society.
Heart Rate Variability Discriminates Competitive Levels in Professional Soccer Players.
Proietti, Riccardo; di Fronso, Selenia; Pereira, Lucas A; Bortoli, Laura; Robazza, Claudio; Nakamura, Fabio Y; Bertollo, Maurizio
2017-06-01
Heart rate variability (HRV) has been increasingly used to monitor team sports athletes. Besides the traditional time domain indices (i.e., the SD of successive RR intervals [SDNN] and the root mean square difference of successive normal RR intervals [RMSSD]), recently the use of the stress score (SS), which is an inverse function of the SD2 index derived from the Poincaré plot, and the sympathetic/parasympathetic ratio (S/PS) to monitor soccer players has been proposed. However, the reliability of these new indices and the ability of HRV to differentiate between soccer competitive levels are unknown. The aim of this study was to analyze the reliability of the different HRV-derived indices in professional soccer players during the competitive period and to compare HRV of professional soccer players from 3 teams of distinct competitive levels (i.e., Italian Second Division [2D], European League [EL], and Champions League [CL]). Fifty-four male professional soccer players from 3 different teams of 2 European countries (Italy and Germany) participated in the study. The intraclass correlation coefficient values of the HRV indices varied from 0.78 (very large) to 0.90 (near perfect). The coefficient of variation (CV) values for RMSSD and SDNN were all <5.00%, although the CV for SS was 6.13% and for S/PS, it was 21.33%. Both the CL and EL groups, assumed to be internationally qualified, presented higher lnRMSSD and lnSDNN and lower lnSS and S/PS than the 2D. Therefore, the HRV can be considered reliable in professional soccer players and is able to differentiate between international- and national-level players.
Narang, Jagriti; Singhal, Chaitali; Malhotra, Nitesh; Narang, Sumit; Pn, Anoop Krishna; Gupta, Riya; Kansal, Ruby; Pundir, C S
2016-12-15
Nanocrystals of zeolites (Nanocrys Zeo) and Multi-walled carbon nanotubes (MWCNT) based diagnostic genosensor was employed for detection of polymerase chain (PCR) amplified HBVDNA in blood of hepatitis B patients. The ssDNA-nanocomposite modified electrode was characterized by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The hybridization between ss DNA probe and target ss DNA was detected by reduction in current, generated by interaction of methylene blue (MB) with free guanine (3'G) of ssDNA. Nanocrys zeo were deposited on the Fluorine doped tin oxide glass electrode (FTO) by drop-casting method for better immobilization of ss DNA while MWCNTs are incorporated into the zeolite-assembly to enhance the electro-conductivity of the present genosensor. The ssDNA-nanocomposite modified FTO electrode exhibited optimum current within 5s, at pH 5.6, and incubation temperature of 45°C. The value of charge transfer resistance (Rct) was linear with the number of copies of target DNA between 150 and 10(6) copies/ml. The limit of detection (LOD) of the sensor was 50 copies/ml. Within and between batches coefficients of variation (CV) were 2.5% and 3.2% respectively. Results obtained with our genosensor were also correlated with those by RT-PCR and r(2) value found with good accuracy of 97%. The electrode was reused by dipping it into 0.1M NaOH for 3min and lost 50% of its initial activity in 4 weeks. Furthermore the technique employed for detection of HBV is EIS, which is convenient and required less analysis time. Copyright © 2016 Elsevier B.V. All rights reserved.
Homeostatic properties of Lactobacillus jensenii engineered as a live vaginal anti-HIV microbicide.
Yamamoto, Hidemi S; Xu, Qiang; Fichorova, Raina N
2013-01-08
Vaginal probiotics are investigated as a binary strategy for prevention of bacterial vaginosis and HIV. We applied an innovative experimental model using primary and immortalized human cervical and vaginal epithelial cells to assess the functional properties of Lactobacillus jensenii, a predominant constituent of the healthy vaginal microbiome, engineered to express the HIV-1 entry inhibitor modified cyanovirin-N (mCV-N). In this model bacteria colonize the epithelial cells over a period of 24-72 h. Staurosporine and the Toll-like receptor 2/6 ligand macrophage-activating lipopeptide-2 (MALP-2) serve as positive controls for apoptosis and proinflammatory activation, respectively. In 24-hour intervals, the colonized epithelium is assessed microscopically, supernatants are collected for measurement of soluble immunoinflammatory mediators and production of CV-N, and cells are lysed for assessment of: 1) apoptosis by cleaved versus total caspase-3 assay; 2) NF-κB activation by a luciferase reporter assay; or 3) epithelia-associated colony forming units (CFU) in Brucella agar. Wild type (WT) L. jensenii 1153 consistently colonized cervical and vaginal cells in the absence of epithelial damage and apoptosis. The bioengineered derivatives expressing mCV-N or control plasmids showed the same stable colonization pattern, which was reproducible between technologists and bacterial batches (CFU coefficient of variation <10% within and between experiments and epithelial cell types). MALP-2 activated NF-κB and caused fold-increased levels of proinflammatory mediators with clinically established significance in the cervicovaginal environment (IL-1α, IL-1β, IL-6, TNF-α, IL-8, RANTES, MIP-3α, and ICAM-1), measured by a multiplex electrochemiluminescence assay. At the same time levels of protective anti-inflammatory mediators interleukin 1 receptor antagonist (IL-1RA) and secretory leukocyte protease inhibitor (SLPI), both measured by ELISA, remained constant (IL-1RA) or moderately increased (SLPI). Similarly to MALP-2, colonization by L. jensenii WT activated NF-κB; however, unlike the synthetic TLR2/6 ligand, the live microorganisms did not induce significant changes in the secreted levels across all inflammation-associated proteins. The mCV-N production and function were confirmed by western blot and a HIV-1 gp120 binding assay, respectively. The bioengineered lactobacilli expressed mCV-N with anti-HIV activity preserved in the epithelial cell context and caused no significant immunoinflammatory changes as compared to the WT L. jensenii. These results highlight the translational value of the colonization model and justify further clinical investigation of the homeostatic and anti-HIV effectiveness of the L. jensenii derivates.
A small whole-body exposure chamber for laboratory use.
O'Shaughnessy, Patrick T; Achutan, Chandran; O'Neill, Marsha E; Thorne, Peter S
2003-03-01
With the development of transgenic and specialized mouse strains, there is an increased need for inhalation exposure systems designed for smaller exposure groups. An inhalation exposure chamber, designed specifically for the exposure of up to 40 mice, was characterized. The chamber was fabricated from 0.32-cm-thick ((1)/(8)-in) aluminum sheets with outside dimensions of 61 cm long by 32 cm high by 34 cm deep, resulting in an internal volume of 65 L. Two stainless-steel open-mesh cages, separated by an absorbent barrier, can be stacked within the central portion of the chamber. Access is provided through a gasketed door with a safety-glass face. Tests were performed to determine the chamber leakage rate, degree of mixing, and spatial variation of two aerosols within the chamber. Results indicated that the fractional leakage rate was 0.0003 min(-1), well below a reported criterion for an operating chamber. Chamber operation gave similar mixing performance with, or without, use of an interior fan. For aerosols with a mass median aerodynamic diameter (MMAD) of 2.56 micro m and 3.14 micro m, the spatial variation of particulate matter concentration resulted in coefficients of variation (CVs) of 4.8% and 11.0%, respectively. These CV values are comparable to those obtained from similar studies involving other inhalation exposure chambers.
Abdominal obesity and all-cause and cardiovascular mortality in end-stage renal disease.
Postorino, Maurizio; Marino, Carmen; Tripepi, Giovanni; Zoccali, Carmine
2009-04-14
The aim of this study was to investigate the predictive value for all-cause and cardiovascular (CV) death of anthropometric measurements of abdominal obesity in patients with end-stage renal disease (ESRD). Surrogate measures of abdominal obesity and segmental fat distribution (waist circumference and waist/hip ratio [WHR]) are stronger predictors of all-cause and CV death than body mass index (BMI) in the general population, but the issue has never been investigated in patients with ESRD. We performed a prospective cohort study in 537 patients with ESRD (age 63 +/- 15 years). In BMI-adjusted Cox models, waist circumference was a direct predictor of all-cause and CV mortality (p < 0.001), whereas BMI showed an inverse relationship (p < 0.001) with these outcomes. The incidence rates of overall and CV death were maximal in patients with relatively lower BMI scores (below the median) and higher waist circumferences (at least the median) and minimal in patients with higher BMI scores (at least the median) and small waist circumferences (below the median). The prognostic power of waist circumference for all-cause (hazard ratio [HR] [10-cm increase]: 1.23; 95% confidence interval [CI]: 1.02 to 1.47; p = 0.03) and CV mortality (HR: 1.37; 95% CI: 1.09 to 1.73; p = 0.006) remained significant after adjustment for CV comorbidities and traditional and emerging risk factors. WHR was found to be related to all-cause (p = 0.009) and CV mortality (p = 0.07). Abdominal obesity underlies a high risk of all-cause and CV mortality in patients with ESRD. Redefinition of nutritional status by combining the metrics of abdominal obesity and BMI may refine prognosis in the ESRD population.
Ho, Cheong-Yip; Kim, Chi-Fai; Leung, Kwok-Nam; Fung, Kwok-Pui; Tse, Tak-Fu; Chan, Helen; Lau, Clara Bik-San
2005-06-01
Coriolus versicolor (CV), also called Yunzhi, has been demonstrated to exert anti-tumor effects on various types of cancer cells, but the underlying mechanism has not been fully elucidated. The present study aimed to evaluate the in vitro anti-tumor activity of a standardized aqueous ethanol extract prepared from CV on four breast cancer cell lines using MTT assay, and test whether the mechanism involves apoptosis induction and modulation of p53 and Bcl-2 protein expressions using cell death detection ELISA, p53 and Bcl-2 ELISAs respectively. Our results demonstrated that the CV extract dose-dependently suppressed the proliferation of three breast tumor cell lines, with ascending order of IC50 values: T-47D, MCF-7, MDA-MB-231, while BT-20 cells were not significantly affected. Tumoricidal activity of the CV extract was found to be comparable to a chemotherapeutic anti-cancer drug, mitomycin C. Nucleosome productions in apoptotic MDA-MB-231, MCF-7 and T-47D cells were significantly augmented in a time-dependent manner and paralleled the anti-proliferative activity of CV extract. Expression of p53 protein was significantly upregulated only in T-47D cells treated with the CV extract in a dose- and time-dependent fashion, but not in MCF-7 (except at 400 mug/ml after 16 h) and MDA-MB-231 cells. The CV extract significantly induced a dose-dependent downregulation of Bcl-2 protein expression in MCF-7 and T-47D cells, but not in MDA-MB-231 cells. These results suggested that apoptosis induction, differentially dependent of p53 and Bcl-2 expressions, might be the possible mechanism of CV extract-mediated cytotoxicity in human breast cancer cells in vitro.
Development of an environmental relative moldiness index for US homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vesper, Sephen J.; McKinstry, Craig A.; Haugland, Richard A.
2007-08-01
As part of the HUD American Healthy Survey, dust samples were collected by vacuuming 2 m2 in the bedroom plus 2 m2 in the living room of a nationally representative 1096 homes in the USA using the Mitest™ sampler. Five mg of sieved (300 µ pore, nylon mesh) dust was analyzed by mold specific quantitative PCR for the 36 EPA Mold Panel Species. On this basis, an “environmental relative moldiness index” (ERMI) was created with values ranging from about -10 to 20 (lowest to highest). In order to try to reduce the cost of this analysis, the number of testmore » species was reduced by selecting only those species with a national average concentration of 30 cell equivalents (CE) per mg dust or greater. Only 19 of 36 species met this criterion. (In 40% of the homes, an additional 46 species were quantified from the same dust sample. All of these species had average concentrations less than 30 CE per mg dust.) These 19 species were then categorized into two groups based on their coefficient of variation (CV). If the CV was > 9, the mold was placed in Category 1 (10/19) and the other molds were placed in Category 2 (9/19). Using these Categories, the sum of the log-transformed concentrations of three Category 2 molds (C. herbarum, A. alternata and C. cladosporioides Type 1) was subtracted from the sum of the log-transformed concentrations of the ten Category 1 molds (Aspergillus niger, A. ochraceus, A. penicillioides, A. restrictus, A. sydowii, Chaetomium globosum, Eurotium amsteldoami, Paecilomyces variotii, Penicillium chrysogenum and Wallemia sebi). Assembling these values for the 1096 AHHS homes from lowest to highest produced the “American relative moldiness index” (ARMI). The correlation between the ERMI and ARMI values was 0.88. The ERMI or ARMI scales may be useful as a standard for mold exposure estimates in epidemiological studies.« less
NASA Astrophysics Data System (ADS)
Morrison, I.; Berenter, J. S.
2017-12-01
SERVIR, the joint USAID and NASA initiative, conducted two studies to assess the value of two distinctly different Early Warning Systems (EWS) in Guatemala and Kenya. Each study applied a unique method to asses EWS value. The evaluation team conducted a Contingent Valuation (CV) choice experiment to measure the value of a near-real time VIIRS and MODIS-based hot-spot mapping tool for forest management professionals targeting seasonal forest fires in Northern Guatemala. The team also conducted a survey-based Damage and Loss Avoidance (DaLA) exercise to calculate the monetary benefits of a MODIS-derived frost forecasting system for farmers in the tea-growing highlands of Kenya. This presentation compares and contrasts the use and utility of these two valuation approaches to assess EWS value. Although interest in these methods is growing, few empirical studies have applied them to benefit and value assessment for EWS. Furthermore, the application of CV and DaLA methods is much less common outside of the developed world. Empirical findings from these two studies indicated significant value for two substantially different beneficiary groups: natural resource management specialists and smallholder tea farmers. Additionally, the valuation processes generated secondary information that can help improve the format and delivery of both types of EWS outputs for user and beneficiary communities in Kenya and Guatemala. Based on lessons learned from the two studies, this presentation will also compare and contrast the methodological and logistical advantages, challenges, and limitations in applying the CV and DaLA methods in developing countries. By reviewing these two valuation methods alongside each other, the authors will outline conditions where they can be applied - individually or jointly - to other early warning systems and delivery contexts.
Ogata, Fumihiko; Kawasaki, Naohito
2016-01-01
In this study, we prepared virgin (S, L) and calcined (S-380, S-1000, L-380, L-1000) magnesium hydroxide for regeneration of waste edible oil. Deterioration of soybean oil, rapeseed oil, and olive oil was achieved by heat and aeration treatment. The properties of the different adsorbents were investigated using specific surface area measurements, scanning electron microscopy, X-ray diffraction analysis, thermogravimetric-differential thermal analysis, and surface pH measurement. Moreover, the relationship between the changes in acid value (AV) and carbonyl value (CV) and the adsorbent properties were evaluated. The specific surface areas of S-380 and L-380 were greater than that of other adsorbents. In addition, the XRD results show that S-380 and L-380 contain both magnesium hydroxide and magnesium oxide structures. The decreases in AV and CV using S-380 and L-380 were greater than achieved using other adsorbents. The correlation coefficients between the decrease in AV and CV and specific surface area were 0.947 for soybean oil, 0.649 for rapeseed oil, and 0.773 for olive oil, respectively. The results obtained in this study suggest that a physical property of the adsorbent, namely specific surface area, was primarily responsible for the observed decreases in AV and CV. Overall, the results suggest that S-380 and L-380 are useful for the regeneration of waste edible oil.
Sun, Lili; Zhou, Liping; Yu, Yu; Lan, Yukun; Li, Zhiliang
2007-01-01
Polychlorinated diphenyl ethers (PCDEs) have received more and more concerns as a group of ubiquitous potential persistent organic pollutants (POPs). By using molecular electronegativity distance vector (MEDV-4), multiple linear regression (MLR) models are developed for sub-cooled liquid vapor pressures (P(L)), n-octanol/water partition coefficients (K(OW)) and sub-cooled liquid water solubilities (S(W,L)) of 209 PCDEs and diphenyl ether. The correlation coefficients (R) and the leave-one-out cross-validation (LOO) correlation coefficients (R(CV)) of all the 6-descriptor models for logP(L), logK(OW) and logS(W,L) are more than 0.98. By using stepwise multiple regression (SMR), the descriptors are selected and the resulting models are 5-descriptor model for logP(L), 4-descriptor model for logK(OW), and 6-descriptor model for logS(W,L), respectively. All these models exhibit excellent estimate capabilities for internal sample set and good predictive capabilities for external samples set. The consistency between observed and estimated/predicted values for logP(L) is the best (R=0.996, R(CV)=0.996), followed by logK(OW) (R=0.992, R(CV)=0.992) and logS(W,L) (R=0.983, R(CV)=0.980). By using MEDV-4 descriptors, the QSPR models can be used for prediction and the model predictions can hence extend the current database of experimental values.
Lyytinen, T.; Bragge, T.; Hakkarainen, M.; Liikavainio, T.; Karjalainen, P.A.; Arokoski, J.P.
2016-01-01
Objectives: To determine the repeatability of knee joint impulsive loading measurements with skin-mounted accelerometers (SMAs) and lower limb surface electromyography (EMG) recordings during gait. Methods: Triaxial SMA and EMG from 4 muscles during level and stair walking in nine healthy and nine knee osteoarthritis (OA) subjects were used. The initial peak acceleration (IPA), root mean square (RMS), maximal acceleration transient rate (ATRmax) and mean EMG activity (EMGact) were calculated. The coefficient of variation (CV) and the intraclass correlation coefficient (ICC) were calculated to measure repeatability. Results: The CV and ICC of RMS accelerations ranged from 4.9% to 10.9% and from 0.69 to 0.96 in both study groups during level walking. The CV and ICC of IPA and ATRmax varied from 7.7% to 14.2% and from 0.85 to 0.99 during level and stairs up walking in healthy subjects. The CV and ICC of EMGact ranged from 8.3% to 31.7% and from 0.16 to 0.97 in both study groups. Conclusions: RMS accelerations exhibited good repeatability during walking in healthy and knee OA subjects. The repeatability of EMG measurements was acceptable in healthy subjects depending on the measured muscles. PMID:26944825
García-Bermúdez, Mercedes; López-Mejías, Raquel; Genre, Fernanda; Castañeda, Santos; Corrales, Alfonso; Llorca, Javier; González-Juanatey, Carlos; Ubilla, Begoña; Miranda-Filloy, José A; Pina, Trinitario; Gómez-Vaquero, Carmen; Rodríguez-Rodríguez, Luis; Fernández-Gutiérrez, Benjamín; Balsa, Alejandro; Pascual-Salcedo, Dora; López-Longo, Francisco J; Carreira, Patricia; Blanco, Ricardo; Martín, Javier; González-Gay, Miguel A
2015-01-01
Rheumatoid arthritis (RA) is a polygenic disease associated with accelerated atherosclerosis and increased cardiovascular (CV) mortality. JAK/STAT signalling pathway is involved in autoimmune diseases and in the atherosclerotic process. JAK3 is a highly promising target for immunomodulatory drugs and polymorphisms in JAK3 gene have been associated with CV events in incident dialysis patients. Therefore, the aim of this study was to assess the potential role of JAK3 polymorphisms in the development of CV disease in patients with RA. 2136 Spanish RA patients were genotyped for the rs3212780 and rs3212752 JAK3 gene polymorphisms by TaqMan assays. Subclinical atherosclerosis was evaluated in 539 of these patients by carotid ultrasonography (US). No statistically significant differences were found when each polymorphism was assessed according to carotid intima-media thickness values and presence/absence of carotid plaques in RA, after adjusting the results for potential confounders. Moreover, no significant differences were obtained when RA patients were stratified according to the presence/absence of CV events after adjusting for potential confounders. In conclusion, our results do not confirm association between JAK3 polymorphisms and CV disease in RA.
García-Bermúdez, Mercedes; López-Mejías, Raquel; Castañeda, Santos; Corrales, Alfonso; González-Juanatey, Carlos; Ubilla, Begoña; Miranda-Filloy, José A.; Pina, Trinitario; Gómez-Vaquero, Carmen; Rodríguez-Rodríguez, Luis; Fernández-Gutiérrez, Benjamín; Balsa, Alejandro; Pascual-Salcedo, Dora; López-Longo, Francisco J.; Carreira, Patricia; Blanco, Ricardo; Martín, Javier; González-Gay, Miguel A.
2015-01-01
Rheumatoid arthritis (RA) is a polygenic disease associated with accelerated atherosclerosis and increased cardiovascular (CV) mortality. JAK/STAT signalling pathway is involved in autoimmune diseases and in the atherosclerotic process. JAK3 is a highly promising target for immunomodulatory drugs and polymorphisms in JAK3 gene have been associated with CV events in incident dialysis patients. Therefore, the aim of this study was to assess the potential role of JAK3 polymorphisms in the development of CV disease in patients with RA. 2136 Spanish RA patients were genotyped for the rs3212780 and rs3212752 JAK3 gene polymorphisms by TaqMan assays. Subclinical atherosclerosis was evaluated in 539 of these patients by carotid ultrasonography (US). No statistically significant differences were found when each polymorphism was assessed according to carotid intima-media thickness values and presence/absence of carotid plaques in RA, after adjusting the results for potential confounders. Moreover, no significant differences were obtained when RA patients were stratified according to the presence/absence of CV events after adjusting for potential confounders. In conclusion, our results do not confirm association between JAK3 polymorphisms and CV disease in RA. PMID:25815310
An Electronic Cigarette Vaping Machine for the Characterization of Aerosol Delivery and Composition.
Havel, Christopher M; Benowitz, Neal L; Jacob, Peyton; St Helen, Gideon
2017-10-01
Characterization of aerosols generated by electronic cigarettes (e-cigarettes) is one method used to evaluate the safety of e-cigarettes. While some researchers have modified smoking machines for e-cigarette aerosol generation, these machines are either not readily available, not automated for e-cigarette testing or have not been adequately described. The objective of this study was to build an e-cigarette vaping machine that can be used to test, under standard conditions, e-liquid aerosolization and nicotine and toxicant delivery. The vaping machine was assembled from commercially available parts, including a puff controller, vacuum pump, power supply, switch to control current flow to the atomizer, three-way value to direct air flow to the atomizer, and three gas dispersion tubes for aerosol trapping. To validate and illustrate its use, the variation in aerosol generation was assessed within and between KangerTech Mini ProTank 3 clearomizers, and the effect of voltage on aerosolization and toxic aldehyde generation were assessed. When using one ProTank 3 clearomizer and different e-liquid flavors, the coefficient of variation (CV) of aerosol generated ranged between 11.5% and 19.3%. The variation in aerosol generated between ProTank 3 clearomizers with different e-liquid flavors and voltage settings ranged between 8.3% and 16.3% CV. Aerosol generation increased linearly at 3-6V across e-liquids and clearomizer brands. Acetaldehyde, acrolein, and formaldehyde generation increased markedly at voltages at or above 5V. The vaping machine that we describe reproducibly aerosolizes e-liquids from e-cigarette atomizers under controlled conditions and is useful for testing of nicotine and toxicant delivery. This study describes an electronic cigarette vaping machine that was assembled from commercially available parts. The vaping machine can be replicated by researchers and used under standard conditions to generate e-cigarette aerosols and characterize nicotine and toxicant delivery. © The Author 2016. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Westera, Liset; van Viegen, Tanja; Jeyarajah, Jenny; Azad, Azar; Bilsborough, Janine; van den Brink, Gijs R; Cremer, Jonathan; Danese, Silvio; D'Haens, Geert; Eckmann, Lars; Faubion, William; Filice, Melissa; Korf, Hannelie; McGovern, Dermot; Panes, Julian; Salas, Azucena; Sandborn, William J; Silverberg, Mark S; Smith, Michelle I; Vermeire, Severine; Vetrano, Stefania; Shackelton, Lisa M; Stitt, Larry; Jairath, Vipul; Levesque, Barrett G; Spencer, David M; Feagan, Brian G; Vande Casteele, Niels
2017-11-02
Flow cytometry (FC) aids in characterization of cellular and molecular factors involved in pathologic immune responses. Although FC has potential to facilitate early drug development in inflammatory bowel disease, interlaboratory variability limits its use in multicenter trials. Standardization of methods may address this limitation. We compared variability in FC-aided quantitation of T-cell responses across international laboratories using three analytical strategies. Peripheral blood mononuclear cells (PBMCs) were isolated from three healthy donors, stimulated with phorbol 12-myristate 13-acetate and ionomycin at a central laboratory, fixed, frozen, and shipped to seven international laboratories. Permeabilization and staining was performed in triplicate at each laboratory using a common protocol and centrally provided reagents. Gating was performed using local gating with a local strategy (LGLS), local gating with a central strategy (LGCS), and central gating (CG). Median cell percentages were calculated across triplicates and donors, and reported for each condition and strategy. The coefficient of variation (CV) was calculated across laboratories. Between-strategy comparisons were made using a two-way analysis of variance adjusting for donor. Mean interlaboratory CV ranged from 1.8 to 102.1% depending on cell population and gating strategy (LGLS, 4.4-102.1%; LGCS, 10.9-65.6%; CG, 1.8-20.9%). Mean interlaboratory CV differed significantly across strategies and was consistently lower with CG. Central gating was the only strategy with mean CVs consistently lower than 25%, which is a proposed standard for pharmacodynamic and exploratory biomarker assays.
Lyubarova, Radmila; Robinson, Jennifer G; Miller, Michael; Simmons, Debra L; Xu, Ping; Abramson, Beth L; Elam, Marshall B; Brown, Todd M; McBride, Ruth; Fleg, Jerome L; Desvigne-Nickens, Patrice; Ayenew, Woubeshet; Boden, William E
Metabolic syndrome (MS) is a well-known risk factor for the development of cardiovascular (CV) disease; yet, controversy persists whether it adds incremental prognostic value in patients with established CV disease. This study was performed to determine if MS is associated with worse CV outcomes in patients with established CV disease treated intensively with statins. We performed a post hoc analysis of the Atherothrombosis Intervention in Metabolic Syndrome with Low HDL/High Triglycerides and Impact on Global Health Outcomes trial, in which patients with established CV disease and atherogenic dyslipidemia (n = 3414) were randomly assigned to receive extended release niacin or placebo during a mean 36-month follow-up, to assess whether the presence of MS or the number of MS components contributed to CV outcomes. The composite primary end point of CV events occurred in 15.1% of patients without MS vs 13.8%, 16.9%, and 16.8% of patients with MS in the subsets with 3, 4, and 5 MS components, respectively (corresponding adjusted hazard ratios 0.9, 1.1, and 1.1 relative to patients without MS), P = .55. Comparing subgroups with 3 vs 4 or 5 MS components, there was no significant difference in either the composite primary end point or secondary end points. Patients with diabetes mellitus had higher event rates, with or without the presence of MS. The presence of MS was not associated with worse CV outcomes in the AIM-HIGH population. The rate of CV events in statin-treated Atherothrombosis Intervention in Metabolic Syndrome with Low HDL/High Triglycerides and Impact on Global Health Outcomes patients with MS was not significantly influenced by the number of MS components. Copyright © 2017 National Lipid Association. All rights reserved.
Eguchi, Kazuo; Imaizumi, Yuki; Kaihara, Toshiki; Hoshide, Satoshi; Kario, Kazuomi
We tested the hypothesis that calcium channel blockers (CCBs: amlodipine group, n = 38)) are superior to angiotensin receptor blockers (ARBs: valsartan group, n = 38) against ambulatory blood pressure variability (BPV) in untreated Japanese hypertensive patients. Both drugs significantly reduced ambulatory systolic and diastolic BP values. With regard to BPV, standard deviation (SD) in SBP did not change with the administration of either drug, but the ARB significantly increased SD in awake DBP (12 ± 4-14 ± 4 mmHg). The ARB also significantly increased the coefficients of variation (CVs)in awake and 24-h SBP/DBP (all P < 0.05), but amlodipine did not change the CV. CCB significantly reduced the maximum values of awake SBP (193 ± 24-182 ± 27 mmHg, P = 0.02), sleep SBP (156 ± 18-139 ± 14 mmHg, P < 0 .001), and awake and sleep DBP (P < 0.01 in both cases), but the ARB did not change the maximum BP values. In conclusion, a once-daily morning dose of CCB amlodipine was more effective at controlling ambulatory BPV than ARB valsartan, especially in reducing maximum BP levels.
Pomorska-Mól, Małgorzata; Czyżewska-Dors, Ewelina; Kwit, Krzysztof; Rachubik, Jarosław; Lipowski, Andrzej; Pejsak, Zygmunt
2015-06-01
The effect of treatment with enrofloxacin was studied on the postvaccinal immune response in pigs. Forty pigs were used (control not vaccinated (C), control vaccinated (CV), vaccinated, received enrofloxacin (ENRO)). From day -1 to day 3 pigs from ENRO group received enrofloxacin at the recommended dose. Pigs from ENRO and CV groups were vaccinated twice against Aujeszky's disease virus (ADV). There was a significant delay in the production of humoral response of enrofloxacin dosed pigs when compared with CV group. Moreover, in ENRO group the significant decrease in IFN-γ production and significantly lower values of stimulation index after ADV restimulation was noted, as compared with CV group. The secretion of IL-6, IL-10 and TNF-α by PBMC after recall stimulation was also affected in ENRO group. The results indicate that enrofloxacin, in addition to its antimicrobial properties, possess significant immunomodulatory effects and may alter the immune response to vaccines. Copyright © 2015 Elsevier Ltd. All rights reserved.
Dodd, Ashley C; Lakomkin, Nikita; Bulka, Catherine; Thakore, Rachel; Collinge, Cory A; Sethi, Manish K
2016-12-01
We investigated geographic variations in Medicare spending for DRG 536 (hip and pelvis fracture). We identified 22,728 patients. The median number of charges, discharges, and payments were recorded. Hospitals were aggregated into core based statistical (CBS) areas and the coefficient of variation (CV) was calculated for each area. On average, hospitals charged 3.75 times more than they were reimbursed. Medicare charges and reimbursements demonstrated variability within each area. Geographic variation in Medicare spending for hip fractures is currently unexplained. It is imperative for orthopedists to understand drivers behind such high variability in hospital charges for management of hip and pelvis fractures.
Multicenter evaluation of the Bayer Immuno I CA 15-3 assay.
Cheli, C D; Morris, D L; Kish, L; Goldblatt, J; Neaman, I; Allard, W J; Yeung, K K; Wu, A H; Moore, R; Chan, D W; Fritsche, H A; Schwartz, M K; Very, D L
1998-04-01
We conducted a multicenter evaluation of the analytical and clinical features of the automated Bayer Immuno 1 CA 15-3 assay and compared assay performance to two manual tests. Results of the 10-day imprecision study of the Bayer Immuno 1 assay pooled across four evaluation sites and three lots of reagent produced total CV < or = 4%. Lot-to-lot reproducibility for 26 different lots of reagents and calibrators manufactured over a 2-year period was demonstrated (CV, 1.1%). Results for the Bayer Immuno 1 assay correlated well with the Biomira TRUQUANT BR 27.29 and Centocor CA 15-3 RIAs (r > or = 0.94). The upper limit of the reference interval for the Bayer Immuno 1 assay was 35.9 kilounits/L (35.9 units/mL); values were similar for all methods. Longitudinal monitoring of healthy women yielded assay values with an average CV of 11% and 21% for the Bayer Immuno 1 and Biomira assays, respectively. The Bayer Immuno 1 assay demonstrated the analytical features, intermethod correlation, and long-term performance characteristics that are essential for longitudinal monitoring of breast cancer patients.
Zhang, Yanzhuo; Li, Jun; Chen, Guanghui; Bian, Wei; Lu, Yun; Li, Wenjing; Zheng, Zhaoming; Cheng, Xiaojie
2016-01-01
The high colority and difficulty of decolorization are the most important tasks on printing and dyeing wastewater. This study investigates the ability of diatomite earth&carbon (DE&C) as an adsorbent to removal crystal violet (CV) from aqueous solutions. Fourier transform infrared spectroscopy results indicate the importance of functional groups during the adsorption of CV. The obtained N2 adsorption-desorption isotherm values accord with well IUPAC type II. Our calculations determined a surface area of 73.15 m(2) g(-1) for DE&C and an average pore diameter of 10.56 nm. Equilibrium data of the adsorption process fitted very well to the Langmuir model (R(2) > 0.99). The results of kinetics study showed that the pseudo-second-order model fitted to the experimental data well. The thermodynamic parameters were also evaluated. ΔH° <0, ΔS° > 0 and ΔG° < 0 demonstrated that the adsorption process was spontaneous and exothermic for dye. Furthermore the positive value of ΔS° reflected good affinity of the CV dye.
Elastography Study of Hamstring Behaviors during Passive Stretching
Le Sant, Guillaume; Ates, Filiz; Brasseur, Jean-Louis; Nordez, Antoine
2015-01-01
Introduction The mechanical properties of hamstring muscles are usually inferred from global passive torque/angle relationships, in combination with adjoining tissues crossing the joint investigated. Shear modulus measurement provides an estimate of changes in muscle-tendon stiffness and passive tension. This study aimed to assess the passive individual behavior of each hamstring muscle in different stretching positions using shear wave elastography. Methods/Results The muscle shear modulus of each hamstring muscle was measured during a standardized slow passive knee extension (PKE, 80% of maximal range of motion) on eighteen healthy male volunteers. Firstly, we assessed the reliability of the measurements. Results were good for semitendinosus (ST, CV: 8.9%-13.4%), semimembranosus (SM, CV: 10.3%-11.2%) and biceps femoris long-head (BF-lh, CV: 8.6%-13.3%), but not for biceps femoris short-head (BF-sh, CV: 20.3%-44.9%). Secondly, we investigated each reliable muscle in three stretch positions: 70°, 90° and 110° of hip flexion. The results showed different values of shear modulus for the same amount of perceived stretch, with the highest measurements in the high-flexed hip situation. Moreover, individual muscles displayed different values, with values increasing or BF-lh, SM and ST, respectively. The inter-subject variability was 35.3% for ST, 27.4% for SM and 30.2% for BF-lh. Conclusion This study showed that the hip needs to be high-flexed to efficiently tension the hamstrings, and reports a higher muscle-tendon stress tolerance at 110° of hip angle. In addition muscles have different passive behaviors, and future works will clarify if it can be linked with rate of injury. PMID:26418862
Karsten, Bettina; Larumbe-Zabala, Eneko; Kandemir, Gokhan; Hazir, Tahir; Klose, Andreas; Naclerio, Fernando
2016-01-01
The objectives of this study were to examine the effects of a moderate intensity strength training on changes in critical velocity (CV), anaerobic running distance (D'), sprint performance and Yo-Yo intermittent running test (Yo-Yo IR1) performances. two recreational soccer teams were divided in a soccer training only group (SO; n = 13) and a strength and soccer training group (ST; n = 13). Both groups were tested for values of CV, D', Yo-Yo IR1 distance and 30-m sprint time on two separate occasions (pre and post intervention). The ST group performed a concurrent 6-week upper and lower body strength and soccer training, whilst the SO group performed a soccer only training. after the re-test of all variables, the ST demonstrated significant improvements for both, YoYo IR1 distance (p = 0.002) and CV values (p<0.001) with no significant changes in the SO group. 30-m sprint performance were slightly improved in the ST group with significantly decreased performance times identified in the SO group (p<0.001). Values for D' were slightly reduced in both groups (ST -44.5 m, 95% CI = -90.6 to 1.6; SO -42.6 m, 95% CI = -88.7 to 3.5). combining a 6-week moderate strength training with soccer training significantly improves CV, Yo-Yo IR1 whilst moderately improving 30-m sprint performances in non-previously resistance trained male soccer players. Critical Velocity can be recommended to coaches as an additional valid testing tool in soccer.
Alayli-Goebbels, Adrienne F G; van Exel, Job; Ament, André J H A; de Vries, Nanne K; Bot, Sandra D M; Severens, Johan L
2015-12-01
To use contingent valuation (CV) to derive individual consumer values for both health and broader benefits of a public-health intervention directed at lifestyle behaviour change (LBC) and to examine the feasibility and validity of the method. Participants of a lifestyle intervention trial (n = 515) were invited to complete an online CV survey. Respondents (n = 312) expressed willingness to invest money and time for changes in life expectancy, health-related quality of life (HRQOL) and broader quality of life aspects. Internal validity was tested for by exploring associations between explanatory variables (i.e. income, paid work, experience and risk factors for cardiovascular diseases) and willingness to invest, and by examining ordering effects and respondents' sensitivity to the scope of the benefits. The majority of respondents (94.3%) attached value to benefits of LBC, and 87.4% were willing to invest both money and time. Respondents were willing to invest more for improvements in HRQOL (€42/month; 3 h/week) and broader quality of life aspects (€40/month; 2.6 h/week) than for improvements in life expectancy (€24/month; 2 h/week). Protest answers were limited (3%) and findings regarding internal validity were mixed. The importance of broader quality of life outcomes to consumers suggests that these outcomes are relevant to be considered in the decision making. Our research showed that CV is a feasible method to value both health and broader outcomes of LBC, but generalizability to other areas of public health still needs to be examined. Mixed evidence regarding internal validity pleads for caution to use CV as only the base for decision making. © 2014 John Wiley & Sons Ltd.
Karsten, Bettina; Larumbe-Zabala, Eneko; Kandemir, Gokhan; Hazir, Tahir; Klose, Andreas; Naclerio, Fernando
2016-01-01
The objectives of this study were to examine the effects of a moderate intensity strength training on changes in critical velocity (CV), anaerobic running distance (D'), sprint performance and Yo-Yo intermittent running test (Yo-Yo IR1) performances. Methods: two recreational soccer teams were divided in a soccer training only group (SO; n = 13) and a strength and soccer training group (ST; n = 13). Both groups were tested for values of CV, D', Yo-Yo IR1 distance and 30-m sprint time on two separate occasions (pre and post intervention). The ST group performed a concurrent 6-week upper and lower body strength and soccer training, whilst the SO group performed a soccer only training. Results: after the re-test of all variables, the ST demonstrated significant improvements for both, YoYo IR1 distance (p = 0.002) and CV values (p<0.001) with no significant changes in the SO group. 30-m sprint performance were slightly improved in the ST group with significantly decreased performance times identified in the SO group (p<0.001). Values for D' were slightly reduced in both groups (ST -44.5 m, 95% CI = -90.6 to 1.6; SO -42.6 m, 95% CI = -88.7 to 3.5). Conclusions: combining a 6-week moderate strength training with soccer training significantly improves CV, Yo-Yo IR1 whilst moderately improving 30-m sprint performances in non-previously resistance trained male soccer players. Critical Velocity can be recommended to coaches as an additional valid testing tool in soccer. PMID:27015418
Buys, Roselien; Coeckelberghs, Ellen; Cornelissen, Véronique A; Goetschalckx, Kaatje; Vanhees, Luc
2016-09-01
Peak oxygen uptake is an independent predictor of mortality in patients with coronary artery disease (CAD). However, patients with CAD are not always capable of reaching peak effort, and therefore submaximal gas exchange variables such as the oxygen uptake efficiency slope (OUES) have been introduced. Baseline exercise capacity as expressed by OUES provides prognostic information and this parameter responds to training. Therefore, we aimed to assess the prognostic value of post-training OUES in patients with CAD. We included 960 patients with CAD (age 60.6 ± 9.5 years; 853 males) who completed a cardiac rehabilitation program between 2000 and 2011. The OUES was calculated before and after cardiac rehabilitation and information on mortality was obtained. The relationships of post-training OUES with all-cause and cardiovascular (CV) mortality was assessed by Cox proportional hazards regression analyses. Receiver operator characteristic curve analysis was performed in order to obtain the optimal cut-off value. During 7.37 ± 3.20 years of follow-up (range: 0.45-13.75 years), 108 patients died, among whom 47 died due to CV reasons. The post-training OUES was related to all-cause (hazard ratio: 0.50, p < 0.001) and CV (hazard ratio: 0.40, p < 0.001) mortality. When significant covariates, including baseline OUES, were entered into the Cox regression analysis, post-training OUES remained related to all-cause and CV mortality (hazard ratio: 0.40, p < 0.01 and 0.26, p < 0.01, respectively). In addition, the change in OUES due to exercise training was positively related to mortality (hazard ratio: 0.49, p < 0.01). Post-training OUES has stronger prognostic value compared to baseline OUES. The lack of improvement in exercise capacity expressed by OUES after an exercise training program relates to a worse prognosis and can help distinguish patients with favorable and unfavorable prognoses. © The European Society of Cardiology 2016.
Laser-Shock Experiments: Calorimetry Measurements to TPa Pressures
NASA Astrophysics Data System (ADS)
Jeanloz, R.
2012-12-01
Laser-driven shock experiments are more like calorimetry measurements, characterized by determinations of Hugoniot temperature (TH) as a function of shock velocity (US), rather than the equation-of-state measurements afforded by mechanical-impact experiments. This is because particle velocity (up) is often not accessible to direct measurement in laser-shock experiments, so must be inferred with reference to a material having a well-determined, independently calibrated Hugoniot equation of state (up is obtained from the impact velocity in traditional shock experiments, and the combination of US and up yields the pressure-density equation of state for the sample). Application of a Mie-Grüneisen model shows that the isochoric specific heat for a given phase is: CV = (US - c0)2 {s2US (dTH/dUS) + γ0 c0 s (TH/US)}-1 with US = c0 + s up, and γ0 is the zero-pressure Grüneisen parameter (γ/V = constant is assumed here). This result is a generalization to TH-US variables of the Walsh and Christian (1955) formula for the temperature rise along the Hugoniot of a given phase (identified here with a US - up relation that is locally linear); it can be analytically integrated to give TH(US) in terms of an average value of CV, if no phase transition takes place. Analysis of the TH-US slopes obtained from laser-shock measurements on MgO yields specific-heat values ranging from 1.02 (± 0.05) kJ/kg/K at 320-345 GPa and TH = 7700-9000 K to 1.50 (± 0.05) kJ/kg/K at 350-380 GPa and TH = 8700-9500 K. A fit to the absolute values of TH(US) in this pressure-temperature range gives CV = 1.26 (± 0.10) kJ/kg/K, in good accord with the Dulong-Petit value CV = 1.24 kJ/kg/K.
Methodological aspects of rat beta-endorphin analysis-influence of diurnal variation.
Finn, Anja; Fabre, Susanne Froelich; Hellström, Per M; Brené, Stefan
2006-05-30
Beta-endorphin radioimmunoassays (RIAs) are widely performed following physical, emotional and environmental challenges in the rat. In the literature, a wide range of techniques have been described, but in the present study, we have focused on methodological aspects of beta-endorphin RIAs, investigating various characteristics of human and rat specific antibodies. Initial studies verified that the RIA outcome was not appropriate when using non-species compatible components. Novel rat beta-endorphin antibodies, r 4114 and r 4268, were raised in rabbits and characterised in terms of specificity, avidity and titer. Both of the new antisera showed 68.1% cross-reactivity with human beta-endorphin. The ED50 was 50+/-8 pmol/l, and the mean ED80 was 17 pmol/l for r 4268 but three-fold higher for r 4114. The intra-assay coefficient of variation (CV) was 7% at 100 pmol/l and the inter-assay CV was 10% at the same level for r 4268 and similar for r 4114. Using this novel rat beta-endorphin RIA for analyses of diurnal influence and removal from the Animal House cage, no significant changes were observed in either the hypothalamus or peri-aqueductal grey regions. These results suggest that rat beta-endorphin concentrations in these brain areas are not affected by order of removal or diurnal variation.
Pollmanns, Johannes; Romano, Patrick S; Weyermann, Maria; Geraedts, Max; Drösler, Saskia E
2018-04-01
To explore effects of disease prevalence adjustment on ambulatory care-sensitive hospitalization (ACSH) rates used for quality comparisons. County-level hospital administrative data on adults discharged from German hospitals in 2011 and prevalence estimates based on administrative ambulatory diagnosis data were used. A retrospective cross-sectional study using in- and outpatient secondary data was performed. Hospitalization data for hypertension, diabetes, heart failure, chronic obstructive pulmonary disease, and asthma were obtained from the German Diagnosis Related Groups (DRG) database. Prevalence estimates were obtained from the German Central Research Institute of Ambulatory Health Care. Crude hospitalization rates varied substantially across counties (coefficients of variation [CV] 28-37 percent across conditions); this variation was reduced by prevalence adjustment (CV 21-28 percent). Prevalence explained 40-50 percent of the observed variation (r = 0.65-0.70) in ACSH rates for all conditions except asthma (r = 0.07). Between 30 percent and 38 percent of areas moved into or outside condition-specific control limits with prevalence adjustment. Unadjusted ACSH rates should be used with caution for high-stakes public reporting as differences in prevalence may have a marked impact. Prevalence adjustment should be considered in models analyzing ACSH. © Health Research and Educational Trust.
Battut, I Barrier; Kempfer, A; Lemasson, N; Chevrier, L; Camugli, S
2017-07-15
Spermatozoa from some stallions do not maintain an acceptable fertility after freezing and thawing. The selection of frozen ejaculates that would be suitable for insemination is mainly based on post-thaw motility, but the prediction of fertility remains limited. A recent study in our laboratory has enabled the determination of a new protocol for the evaluation of fresh stallion semen, combining microscopical observation, computer-assisted motility analysis and flow cytometry, and providing a high level of fertility prediction. The purpose of the present experiment was to perform similar investigations on frozen semen. A panel of tests evaluating a large number of compartments or functions of the spermatozoa was applied to a population of 42 stallions, 33 of which showing widely differing fertilities (17-67% pregnancy rate per cycle [PRC]). Variability was evaluated by calculating the coefficient of variation (CV=SD/mean) and the intra-class correlation or "repeatability" for each variable. For paired variables, mean within-stallion CV% was significantly lower than between-stallion CV%, which was significantly lower than total CV%. Within-ejaculate repeatability, determined by analysing 6 straws for each of 10 ejaculates, ranged from 0.60 to 0.97. Within-stallion repeatability, determined by analysing at least 5 ejaculates for each of 38 stallions, ranged from 0.12 to 0.95. Principal component regression using a combination of 25 variables, including motility, morphology, viability, oxidation level, acrosome integrity, DNA integrity and hypoosmotic resistance, accounted for 94.5% of the variability regarding fertility, and was used to calculate a prediction of the PRC with a mean standard deviation of 2.2. The difference between the observed PRC and the calculated value ranged from -3.4 to 4.2. The 90% confidence interval (90CI) for the prediction of the PRC for the stallions of unknown fertility ranged from 8 to 30 (mean = 17). The best-fit model using only motility variables, evaluated after 10 min at 36 °C and 2 h at 36 °C or room temperature, accounted for only 74.2% of the variability. The difference between the observed PRC and the calculated value ranged from -7.2 to 14. The 90CI for the prediction of the PRC for the stallions of unknown fertility ranged from 23 to 48 (mean = 33). In conclusion, this study demonstrated that an appropriate combination of computer-assisted motility analysis, microscopical observation and flow cytometry can provide a higher prediction of fertility than motility analysis alone. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Spector, E.; LeBlanc, A.; Shackelford, L.
1995-01-01
This study reports on the short-term in vivo precision and absolute measurements of three combinations of whole-body scan modes and analysis software using a Hologic QDR 2000 dual-energy X-ray densitometer. A group of 21 normal, healthy volunteers (11 male and 10 female) were scanned six times, receiving one pencil-beam and one array whole-body scan on three occasions approximately 1 week apart. The following combinations of scan modes and analysis software were used: pencil-beam scans analyzed with Hologic's standard whole-body software (PB scans); the same pencil-beam analyzed with Hologic's newer "enhanced" software (EPB scans); and array scans analyzed with the enhanced software (EA scans). Precision values (% coefficient of variation, %CV) were calculated for whole-body and regional bone mineral content (BMC), bone mineral density (BMD), fat mass, lean mass, %fat and total mass. In general, there was no significant difference among the three scan types with respect to short-term precision of BMD and only slight differences in the precision of BMC. Precision of BMC and BMD for all three scan types was excellent: < 1% CV for whole-body values, with most regional values in the 1%-2% range. Pencil-beam scans demonstrated significantly better soft tissue precision than did array scans. Precision errors for whole-body lean mass were: 0.9% (PB), 1.1% (EPB) and 1.9% (EA). Precision errors for whole-body fat mass were: 1.7% (PB), 2.4% (EPB) and 5.6% (EA). EPB precision errors were slightly higher than PB precision errors for lean, fat and %fat measurements of all regions except the head, although these differences were significant only for the fat and % fat of the arms and legs. In addition EPB precision values exhibited greater individual variability than PB precision values. Finally, absolute values of bone and soft tissue were compared among the three combinations of scan and analysis modes. BMC, BMD, fat mass, %fat and lean mass were significantly different between PB scans and either of the EPB or EA scans. Differences were as large as 20%-25% for certain regional fat and BMD measurements. Additional work may be needed to examine the relative accuracy of the scan mode/software combinations and to identify reasons for the differences in soft tissue precision with the array whole-body scan mode.
Quantification of retinal pigment epithelial phenotypic variation using laser scanning cytometry.
Hjelmeland, L M; Fujikawa, A; Oltjen, S L; Smit-McBride, Z; Braunschweig, D
2010-06-16
Quantifying phenotypic variation at the level of protein expression (variegation) within populations of retinal pigment epithelium (RPE) cells may be important in the study of pathologies associated with this variation. The lack of quantitative methods for examining single cells, however, and the variable presence of pigment and/or lipofuscin complicate this experimental goal. We have applied the technique of laser scanning cytometry (LSC) to paraffin sections of mouse and human eyes to evaluate the utility of LSC for these measurements. Mouse eyes were perfusion fixed in 4% paraformaldehyde and embedded in paraffin. Postmortem human eyes were fixed and dissected to obtain a 9-mm punch, which was then embedded in paraffin. A laser scanning cytometer equipped with violet, argon, and helium-neon lasers and the detectors for blue, green, and long red were used to record the fluorescence of each individual cell at all three wavelengths. Raw data were recorded and processed using the WinCyte software. Individual nuclei were identified by the fluorescence of the 4',6-diamidino-2-phenylindole (DAPI) nuclear counterstain. Next, RPE cells were uniquely identified in the green channel using an anti-retinal pigment epithelium-specific protein 65 kDa (anti-RPE65) monoclonal antibody with an Alexa Fluor 488-labeled secondary antibody. Mn-superoxide dismutase (MnSOD) was quantified in the long-red channel using an anti-MnSOD antibody and an Alexa Fluor 647-labeled secondary antibody. MnSOD(+) and RPE65(+) cells exhibited peaks in the plot of fluorescence intensity versus cell number, which could be characterized by the mean fluorescence intensity (MFI), the coefficient of variation (CV), and the percentage of total RPE cells that were also labeled for MnSOD. RPE cells can be uniquely identified in human and mouse paraffin sections by immunolabeling with anti-RPE65 antibody. A second antigen, such as MnSOD, can then be probed only within this set of RPE. Results are plotted primarily with the population frequency diagram, which can be subdivided into multiple regions. The data collected for each region include the MFI, the CV, and the number of cells that are immunolabeled in that region. Background interference from pigment or autofluorescent material can be successfully overcome by elevating the concentrations of fluorescent secondary antibodies. In the human and mouse eyes, age-related changes in MFI, CV, and percent RPE cells immunolabeled for MnSOD were observed. The extent of the variability of gene expression in RPE cells at the protein level can be quantified by LSC. Relative changes in the MFI, the CV, and/or percentage of RPE cells double labeled for a second antigen quantify the changes observed. The analysis of these data also suggest whether the effects observed are related to local changes in transcription (alterations of CV) or major changes of protein expression (MFI), which are likely to be due to changes in the chromatin structure. The changes of these variables with age suggest that the observed age-related variegation is primarily due to changes in the chromatin structure in individual cells.
Evaluation of the coagulometer STA R Max® (Stago) for routine coagulation parameters.
Brulé, Justine; Sinegre, Thomas; Pereira, Bruno; Berger, Marc G; Serre-Sapin, Anne-Françoise; Lebreton, Aurélien
2018-04-01
The STA R Max ® is a fully automated multiparameter coagulometer using clotting (viscosity-based detection system), chromogenic and immunologic assays. STA R Max ® is equipped with an innovative software (STA Coag Expert ® ) designed to assist laboratory in accreditation. The aim of this study was to evaluate its performances for the certification according to ISO 15189 quality standard in the haemostasis unit of our university hospital. The following tests were evaluated: prothrombin time (PT), activated partial thromboplastin time (aPTT), kaolin cephalin clotting time (KCCT), fibrinogen, anti-Xa assay and D-dimers. In normal and pathological range, the intra-assay coefficients of variation (CV) for PT, aPTT, KCCT and fibrinogen were below 4.0%. Intra-assay CV was of 4.0% for the anti-Xa assay and intra-assay CV was of 7.9% for D-dimers. Inter-assay CV were below 5.0% for PT, aPPT, KCCT and fibrinogen, 14.9% for anti-Xa assay and 8.6% for D-dimers. The interlaboratory comparisons were below 8.7% for PT, aPPT and KCCT, 5.0% for fibrinogen and 15.5% for anti-Xa assay. All results were acceptable according to suitable CV established by GFHT and the provider. The concordance between all coagulometers was excellent, with correlation coefficient close to 1 (0.99 for all parameters except for aPPT which was 0.98) calculated thanks to an intra-class correlation study. In conclusion, the STA R Max ® analyser is suitable for haemostasis laboratories and facilitates certification of a laboratory.
Oral and vocal fold diadochokinesis in dysphonic women.
Louzada, Talita; Beraldinelle, Roberta; Berretin-Felix, Giédre; Brasolotto, Alcione Ghedini
2011-01-01
The evaluation of oral and vocal fold diadochokinesis (DDK) in individuals with voice disorders may contribute to the understanding of factors that affect the balanced vocal production. Scientific studies that make use of this assessment tool support the knowledge advance of this area, reflecting the development of more appropriate therapeutic planning. To compare the results of oral and vocal fold DDK in dysphonic women and in women without vocal disorders. For this study, 28 voice recordings of women from 19 to 54 years old, diagnosed with dysphonia and submitted to a voice assessment from speech pathologist and otorhinolaryngologist, were used. The control group included 30 nondysphonic women evaluated in prior research from normal adults. The analysis parameters like number and duration of emissions, as well as the regularity of the repetition of syllables "pa", "ta", "ka" and the vowels "a" and "i," were provided by the Advanced Motor Speech Profile program (MSP) Model-5141, version-2.5.2 (KayPentax). The DDK sequence "pataka" was analyzed quantitatively through the Sound Forge 7.0 program, as well as manually with the audio-visual help of sound waves. Average values of oral and vocal fold DDK dysphonic and nondysphonic women were compared using the "t Student" test and were considered significant when p<0.05. The findings showed no significant differences between populations; however, the coefficient of variation of period (CvP) and jitter of period (JittP) average of the "ka," "a" and "i" emissions, respectively, were higher in dysphonic women (CvP=10.42%, 12.79%, 12.05%; JittP=2.05%, 6.05%, 3.63%) compared to the control group (CvP=8.86%; 10.95%, 11.20%; JittP=1.82%, 2.98%, 3.15%). Although the results do not indicate any difficulties in oral and laryngeal motor control in the dysphonic group, the largest instability in vocal fold DDK in the experimental group should be considered, and studies of this ability in individuals with communication disorders must be intensified.
Kubitza, Dagmar; Becka, Michael; Mück, Wolfgang; Krätzschmar, Jöern
2014-01-01
Aims This study investigated relevant pharmacodynamic and pharmacokinetic parameters during the transition from warfarin to rivaroxaban in healthy male subjects. Methods Ninety-six healthy men were randomized into the following three groups: warfarin [international normalized ratio (INR) 2.0–3.0] transitioned to rivaroxaban 20 mg once daily (od; group A); warfarin (INR 2.0–3.0) followed by placebo od (group B); and rivaroxaban alone 20 mg od (group C) for 4 days. Anti-factor Xa activity, inhibition of factor Xa activity, prothrombin time (PT), activated partial thromboplastin time, HepTest, prothrombinase-induced clotting time, factor VIIa activity, factor IIa activity, endogenous thrombin potential and pharmacokinetics were measured. Results An additive effect was observed on the PT and PT/INR during the initial transition period. The mean maximal prolongation of PT was 4.39-fold [coefficient of variation (CV) 18.03%; range 3.39–6.50] of the baseline value in group A, compared with 1.88-fold (CV 10.35%; range 1.53–2.21) in group B and 1.57-fold (CV 9.98%; range 1.37–2.09) in group C. Rivaroxaban had minimal influence on the PT/INR at trough levels. Inhibition of factor Xa activity, activated partial thromboplastin time and endogenous thrombin potential were also enhanced, but to a lesser extent. In contrast, the effects of rivaroxaban on anti-factor Xa activity, HepTest and prothrombinase-induced clotting time were not affected by pretreatment with warfarin. Conclusions Changes in pharmacodynamics during the transition from warfarin to rivaroxaban vary depending on the test used. A supra-additive effect on PT/INR is expected during the initial period of transition, but pretreatment with warfarin does not influence the effect of rivaroxaban on anti-factor Xa activity. PMID:24528331
Radial measurements of IMF-sensitive absorption features in two massive ETGs
NASA Astrophysics Data System (ADS)
Vaughan, Sam P.; Davies, Roger L.; Zieleniewski, Simon; Houghton, Ryan C. W.
2018-03-01
We make radial measurements of stellar initial mass function (IMF) sensitive absorption features in the two massive early-type galaxies NGC 1277 and IC 843. Using the Oxford Short Wavelength Integral Field specTrogaph (SWIFT), we obtain resolved measurements of the Na I 0.82 and FeH 0.99 indices, amongst others, finding both galaxies show strong gradients in Na I absorption combined with flat FeH profiles at ˜0.4 Å. We find these measurements may be explained by radial gradients in the IMF, appropriate abundance gradients in [Na/Fe] and [Fe/H], or a combination of the two, and our data are unable to break this degeneracy. We also use full spectral fitting to infer global properties from an integrated spectrum of each object, deriving a unimodal IMF slope consistent with Salpeter in IC 843 (x = 2.27 ± 0.17) but steeper than Salpeter in NGC 1277 (x = 2.69 ± 0.11), despite their similar FeH equivalent widths. Independently, we fit the strength of the FeH feature and compare to the E-MILES and CvD12 stellar population libraries, finding agreement between the models. The IMF values derived in this way are in close agreement with those from spectral fitting in NGC 1277 (x_{CvD}=2.59^{+0.25}_{-0.48}, x_{E-MILES}=2.77± 0.31), but are less consistent in IC 843, with the IMF derived from FeH alone leading to steeper slopes than when fitting the full spectrum (x_{CvD}=2.57^{+0.30}_{-0.41}, x_{E-MILES}=2.72± 0.25). This work highlights the importance of a large wavelength coverage for breaking the degeneracy between abundance and IMF variations, and may bring into doubt the use of the Wing-Ford band as an IMF index if used without other spectral information.
Bari, Vlasta; De Maria, Beatrice; Mazzucco, Claudio Enrico; Rossato, Gianluca; Tonon, Davide; Nollo, Giandomenico; Faes, Luca; Porta, Alberto
2017-05-01
A model-based conditional transfer entropy approach was exploited to quantify the information transfer in cerebrovascular (CBV) and cardiovascular (CV) systems in subjects prone to develop postural syncope. Spontaneous beat-to-beat variations of mean cerebral blood flow velocity (MCBFV) derived from a transcranial Doppler device, heart period (HP) derived from surface electrocardiogram, mean arterial pressure (MAP) and systolic arterial pressure (SAP) derived from finger plethysmographic arterial pressure device were monitored at rest in supine position (REST) and during 60° head-up tilt (TILT) in 13 individuals (age mean ± standard deviation: 28 ± 9 years, min-max range: 18-44 years, 5 males) with a history of recurrent episodes of syncope (SYNC) and in 13 age- and gender-matched controls (NonSYNC). Respiration (R) obtained from a thoracic belt was acquired as well and considered as a conditioning signal in transfer entropy assessment. Synchronous sequences of 250 consecutive MCBFV, HP, MAP, SAP and R values were utilized to estimate the information genuinely transferred from MAP to MCBFV (i.e. disambiguated from R influences) and vice versa. Analogous indexes were computed from SAP to HP and vice versa. Traditional time and frequency domain analyses were carried out as well. SYNC subjects showed an increased genuine information transfer from MAP to MCBFV during TILT, while they did not exhibit the expected rise of the genuine information transfer from SAP to HP. We conclude that SYNC individuals featured an impaired cerebral autoregulation visible during TILT and were unable to activate cardiac baroreflex to cope with the postural challenge. Traditional frequency domain markers based on transfer function modulus, phase and coherence functions were less powerful or less specific in typifying the CBV and CV controls of SYNC individuals. Conditional transfer entropy approach can identify the impairment of CBV and CV controls and provide specific clues to identify subjects prone to develop postural syncope.
Bożek, Agnieszka; Reich, Adam
2017-08-01
A wide variety of psoriasis assessment tools have been proposed to evaluate the severity of psoriasis in clinical trials and daily practice. The most frequently used clinical instrument is the psoriasis area and severity index (PASI); however, none of the currently published severity scores used for psoriasis meets all the validation criteria required for an ideal score. The aim of this study was to compare and assess the reliability of 3 commonly used assessment instruments for psoriasis severity: the psoriasis area and severity index (PASI), body surface area (BSA) and physician global assessment (PGA). On the scoring day, 10 trained dermatologists evaluated 9 adult patients with plaque-type psoriasis using the PASI, BSA and PGA. All the subjects were assessed twice by each physician. Correlations between the assessments were analyzed using the Pearson correlation coefficient. Intra-class correlation coefficient (ICC) was calculated to analyze intra-rater reliability, and the coefficient of variation (CV) was used to assess inter-rater variability. Significant correlations were observed among the 3 scales in both assessments. In all 3 scales the ICCs were > 0.75, indicating high intra-rater reliability. The highest ICC was for the BSA (0.96) and the lowest one for the PGA (0.87). The CV for the PGA and PASI were 29.3 and 36.9, respectively, indicating moderate inter-rater variability. The CV for the BSA was 57.1, indicating high inter-rater variability. Comparing the PASI, PGA and BSA, it was shown that the PGA had the highest inter-rater reliability, whereas the BSA had the highest intra-rater reliability. The PASI showed intermediate values in terms of interand intra-rater reliability. None of the 3 assessment instruments showed a significant advantage over the other. A reliable assessment of psoriasis severity requires the use of several independent evaluations simultaneously.
High variability in baseline urinary free cortisol values in patients with Cushing's disease.
Petersenn, S; Newell-Price, J; Findling, J W; Gu, F; Maldonado, M; Sen, K; Salgado, L R; Colao, A; Biller, B M K
2014-02-01
Twenty-four-hour urinary free cortisol (UFC) sampling is commonly used to evaluate Cushing's syndrome. Because there are few data on UFC variability in patients with active Cushing's disease, we analysed baseline UFC in a large patient cohort with moderate-to-severe Cushing's disease and assessed whether variability correlates with hypercortisolism severity. These data will help clinicians establish the minimum number of UFC samples required to obtain reliable data. Observational study (enrolment phase of Phase III study). Patients (n = 152) with persistent/recurrent or de novo Cushing's disease and mean UFC (mUFC) ≥1·5×ULN (normal: 30-145 nmol/24 h) were included. Mean UFC level was calculated from four 24-h urine samples collected over 2 weeks. Over 600 24-h UFC samples were analysed. The mUFC levels of samples 1 and 2 and samples 3 and 4 were 1000 nmol/24 h (SD 1872) and 940 nmol/24 h (SD 2148), respectively; intrapatient coefficient of variation (CV) was 38% for mUFC. The intrapatient CV using all four samples was 52% (95% CI: 48-56). The intrapatient CV was 51% (95% CI: 44-58) for samples 1 and 2, 49% (95% CI: 43-56) for samples 3 and 4 and 54% (95% CI: 49-59) for samples 1, 2 and 3. Variability in mUFC increased as UFC levels increased. There were no correlations between UFC and clinical features of hypercortisolism. There is intrapatient variability of approximately 50% in 24-h UFC measurements, which is relevant to targets set to estimate any treatment effect. Analysing more than two 24-h collection periods in individual patients does not result in a relevant decrease in variability. Interestingly, UFC levels did not correlate with hypercortisolism severity. © 2013 The Authors. Clinical Endocrinology published by John Wiley & Sons Ltd.
Read, Paul J; Oliver, Jon L; Croix, Mark Ba De Ste; Myer, Gregory D; Lloyd, Rhodri S
2016-12-01
Read, P, Oliver, JL, Croix, MD, Myer, GD, and Lloyd, RS. Consistency of field-based measures of neuromuscular control using force-plate diagnostics in elite male youth soccer players. J Strength Cond Res 30(12): 3304-3311, 2016-Deficits in neuromuscular control during movement patterns such as landing are suggested pathomechanics that underlie sport-related injury. A common mode of assessment is measurement of landing forces during jumping tasks; however, these measures have been used less frequently in male youth soccer players, and reliability data are sparse. The aim of this study was to examine the reliability of a field-based neuromuscular control screening battery using force-plate diagnostics in this cohort. Twenty-six pre-peak height velocity (PHV) and 25 post-PHV elite male youth soccer players completed a drop vertical jump (DVJ), single-leg 75% horizontal hop and stick (75%HOP), and single-leg countermovement jump (SLCMJ). Measures of peak landing vertical ground reaction force (pVGRF), time to stabilization, time to pVGRF, and pVGRF asymmetry were recorded. A test-retest design was used, and reliability statistics included change in mean, intraclass correlation coefficient, and coefficient of variation (CV). No significant differences in mean score were reported for any of the assessed variables between test sessions. In both groups, pVGRF and asymmetry during the 75%HOP and SLCMJ demonstrated largely acceptable reliability (CV ≤ 10%). Greater variability was evident in DVJ pVGRF and all other assessed variables, across the 3 protocols (CV range = 13.8-49.7%). Intraclass correlation coefficient values ranged from small to large and were generally higher in the post-PHV players. The results of this study suggest that pVGRF and asymmetry can be reliably assessed using a 75%HOP and SLCMJ in this cohort. These measures could be used to support a screening battery for elite male youth soccer players and for test-retest comparison.
Core Problem: Does the CV Parent Body Magnetization require differentiation?
NASA Astrophysics Data System (ADS)
O'Brien, T.; Tarduno, J. A.; Smirnov, A. V.
2016-12-01
Evidence for the presence of past dynamos from magnetic studies of meteorites can provide key information on the nature and evolution of parent bodies. However, the suggestion of a past core dynamo for the CV parent body based on the study of the Allende meteorite has led to a paradox: a core dynamo requires differentiation, evidence for which is missing in the meteorite record. The key parameter used to distinguish core dynamo versus external field mechanisms is absolute field paleointensity, with high values (>>1 μT) favoring the former. Here we explore the fundamental requirements for absolute field intensity measurement in the Allende meteorite: single domain grains that are non-interacting. Magnetic hysteresis and directional data define strong magnetic interactions, negating a standard interpretation of paleointensity measurements in terms of absolute paleofield values. The Allende low field magnetic susceptibility is dominated by magnetite and FeNi grains, whereas the magnetic remanence is carried by an iron sulfide whose remanence-carrying capacity increases with laboratory cycling at constant field values, indicating reordering. The iron sulfide and FeNi grains are in close proximity, providing mineralogical context for interactions. We interpret the magnetization of Allende to record the intense early solar wind with metal-sulfide interactions amplifying the field, giving the false impression of a higher field value in some prior studies. An undifferentiated CV parent body is thus compatible with Allende's magnetization. Early solar wind magnetization should be the null hypothesis for evaluating the source of magnetization for chondrites and other meteorites.
NASA Technical Reports Server (NTRS)
Greenwood, R. C.; Franchi, I. A.; Zolensky, M. E.; Buchanan, P. C.
2016-01-01
The process responsible for the mass independent oxygen isotope variation observed in Solar System materials remains poorly understood. While self-shielding of CO, either in the early solar nebula, or precursor molecular cloud, appears to be a viable mechanism, alternative models have also been proposed.
Impact of heterozygosity and heterogeneity on cotton lint yield stability: II. Lint yield components
USDA-ARS?s Scientific Manuscript database
In order to determine which yield components may contribute to yield stability, an 18-environment field study was undertaken to observe the mean, standard deviation (SD), and coefficient of variation (CV) for cotton lint yield components in population types that differed for lint yield stability. Th...
Word Recognition Processing Efficiency as a Component of Second Language Listening
ERIC Educational Resources Information Center
Joyce, Paul
2013-01-01
This study investigated the application of the speeded lexical decision task to L2 aural processing efficiency. One-hundred and twenty Japanese university students completed an aural word/nonword task. When the variation of lexical decision time (CV) was correlated with reaction time (RT), the results suggested that the single-word recognition…
The effects of gamma irradiation on electrical characteristics of Zn/ZnO/n-Si/Au-Sb structure
NASA Astrophysics Data System (ADS)
Salari, M. Abdolahpour; Güzeldir, B.; Saǧlam, M.
2018-02-01
In this research, we have investigated the electrical characteristics of Zn/ZnO/n-Si/Au-Sb structure before and after 60Co gamma (γ)-ray source irradiation with the total dose range of 0-500 kGy at room temperature. Electrical measurements of this structure have been performed using current-voltage (I-V) and capacitance-voltage (C-V) techniques. Experimental results show that the values of the ideality factor obtained from I-V measurements increased and the values of the barrier height obtained from reverse-bias C-V measurements decreased after gamma-irradiation. The results show that the main effect of the radiation is the generation of laterally inhomogeneous defects near the semiconductor surface.
Phenotypic Variations in the Foliar Chemical Profile of Persea americana Mill. cv. Hass.
García-Rodríguez, Yolanda Magdalena; Torres-Gurrola, Guadalupe; Meléndez-González, Claudio; Espinosa-García, Francisco J
2016-12-01
The Hass avocado tree Persea americana cv. Hass was derived from a single hybrid tree of P. americana var. drymifolia and P. americana var. guatemalensis, and it is propagated clonally by grafting. This cultivar is the most widely planted in the world but its profile of secondary metabolites has been studied rarely despite of its importance in plant protection. We illustrate the variability of the volatilome of mature leaves by describing the average chemical composition and the phenotypic variability found in 70 trees. Contrary to the uniformity expected in the Hass cultivar, high variability coefficients were found for most of the 36 detected foliar volatile compounds; furthermore we found six chemotypes grouping the foliar phenotypes of the sampled trees using hierarchical cluster analysis. About 48% of trees were grouped in one chemotype; five chemotypes grouped the remaining trees. The compounds that determined these chemotypes were: estragole, α-farnesene, β-caryophyllene, germacrene D, α-cubebene and eugenol. This striking variation in a cultivar propagated clonally is discussed in terms of somatic mutation. © 2016 Wiley-VHCA AG, Zurich, Switzerland.
van den Berg, Gerard J; Doblhammer-Reiter, Gabriele; Christensen, Kaare
2011-05-01
We connect the recent medical and economic literatures on the long-run effects of early-life conditions by analyzing the effects of economic conditions on the individual cardiovascular (CV) mortality rate later in life, using individual data records from the Danish Twin Registry covering births since the 1870s and including the cause of death. To capture exogenous variation of conditions early in life, we use the state of the business cycle around birth. We find significant negative effects of economic conditions around birth on the individual CV mortality rate at higher ages. There is no effect on the cancer-specific mortality rate. From variation within and between monozygotic and dizygotic twin pairs born under different conditions, we conclude that the fate of an individual is more strongly determined by genetic and household-environmental factors if early-life conditions are poor. Individual-specific qualities come more to fruition if the starting position in life is better.
Spatial Normalization of Reverse Phase Protein Array Data
Kaushik, Poorvi; Molinelli, Evan J.; Miller, Martin L.; Wang, Weiqing; Korkut, Anil; Liu, Wenbin; Ju, Zhenlin; Lu, Yiling; Mills, Gordon; Sander, Chris
2014-01-01
Reverse phase protein arrays (RPPA) are an efficient, high-throughput, cost-effective method for the quantification of specific proteins in complex biological samples. The quality of RPPA data may be affected by various sources of error. One of these, spatial variation, is caused by uneven exposure of different parts of an RPPA slide to the reagents used in protein detection. We present a method for the determination and correction of systematic spatial variation in RPPA slides using positive control spots printed on each slide. The method uses a simple bi-linear interpolation technique to obtain a surface representing the spatial variation occurring across the dimensions of a slide. This surface is used to calculate correction factors that can normalize the relative protein concentrations of the samples on each slide. The adoption of the method results in increased agreement between technical and biological replicates of various tumor and cell-line derived samples. Further, in data from a study of the melanoma cell-line SKMEL-133, several slides that had previously been rejected because they had a coefficient of variation (CV) greater than 15%, are rescued by reduction of CV below this threshold in each case. The method is implemented in the R statistical programing language. It is compatible with MicroVigene and SuperCurve, packages commonly used in RPPA data analysis. The method is made available, along with suggestions for implementation, at http://bitbucket.org/rppa_preprocess/rppa_preprocess/src. PMID:25501559
Li, Jin-ming; Zheng, Huai-jing; Wang, Lu-nan; Deng, Wei
2003-04-01
To establish a model for one choosing controls with a suitable concentration for internal quality control (IQC) with qualitative ELISA detection, and a consecutive plotting method on Levey-Jennings control chart when reagent kit lot is changed. First, a series of control serum with 0.2, 0.5, 1.0, 2.0 and 5.0ng/ml HBsAg respectively were assessed for within-run and between-run precision according to NCCLs EP5 document. Then, a linear regression equation (y=bx + a) with best correlation coefficient (r > 0.99) was established based on S/CO values of the series of control serum. Finally, one could choose controls with S/CO value calculated from the equation (y = bx + a) minus the product of the S/CO value multiplying three-fold between-run CV to be still more than 1.0 for IQC use. For consecutive plotting on Levey-Jennings control chart when ELISA kit lot was changed, the new lot kits were used to detect the same series of HBsAg control serum as above. Then, a new linear regression equation (y2 = b2x2 + a2) with best correlation coefficient was obtained. The old one (y1 =b1x1 + a1) could be obtained based on the mean values from above precision assessment. The S/CO value of a control serum detected by new lot kit could be changed to that detected by old kit lot based on the factor of y2/y1. Therefore, the plotting on primary Levey-Jennings control chart could be continued. The within-run coefficient of variation CV of the ELISA method for control serum with 0.2, 0.5, 1.0, 2.0 and 5.0ng/ml HBsAg were 11.08%, 9.49%, 9.83%, 9.18% and 7.25%, respectively, and between-run CV were 13.25%, 14.03%, 15.11%, 13.29% and 9.92%. The linear regression equation with best correlation coefficient from a test at random was y = 3.509x + 0.180. The suitable concentration of control serum for IQC could be 0.5ng/ml or 1.0ng/ml. The linear regression equation from the old lot and other two new lots of the ELISA kits were y1 = 3.550(x1) + 0.226, y2 = 3.238(x2) +0.388, and y3 =3.428(x3) + 0.148, respectively. Then, the transferring factors of 0.960 (y2/y1) and 0.908 (y3/y1) were obtained. The results shows that the model established for IQC control serum concentration selecting and for consecutive plotting on control chart when the reagent lot is changed is effective and practical.
2010-01-01
Background Expansins form a large multi-gene family found in wheat and other cereal genomes that are involved in the expansion of cell walls as a tissue grows. The expansin family can be divided up into two main groups, namely, alpha-expansin (EXPA) and beta-expansin proteins (EXPB), with the EXPB group being of particular interest as group 1-pollen allergens. Results In this study, three beta-expansin genes were identified and characterized from a newly sequenced region of the Triticum aestivum cv. Chinese Spring chromosome 3B physical map at the Sr2 locus (FPC contig ctg11). The analysis of a 357 kb sub-sequence of FPC contig ctg11 identified one beta-expansin genes to be TaEXPB11, originally identified as a cDNA from the wheat cv Wyuna. Through the analysis of intron sequences of the three wheat cv. Chinese Spring genes, we propose that two of these beta-expansin genes are duplications of the TaEXPB11 gene. Comparative sequence analysis with two other wheat cultivars (cv. Westonia and cv. Hope) and a Triticum aestivum var. spelta line validated the identification of the Chinese Spring variant of TaEXPB11. The expression in maternal and grain tissues was confirmed by examining EST databases and carrying out RT-PCR experiments. Detailed examination of the position of TaEXPB11 relative to the locus encoding Sr2 disease resistance ruled out the possibility of this gene directly contributing to the resistance phenotype. Conclusions Through 3-D structural protein comparisons with Zea mays EXPB1, we proposed that variations within the coding sequence of TaEXPB11 in wheats may produce a functional change within features such as domain 1 related to possible involvement in cell wall structure and domain 2 defining the pollen allergen domain and binding to IgE protein. The variation established in this gene suggests it is a clearly identifiable member of a gene family and reflects the dynamic features of the wheat genome as it adapted to a range of different environments and uses. Accession Numbers: ctg11 =FN564426 Survey sequences of TaEXPB11ws and TsEXPB11 are provided request. PMID:20507562
Srivastava, A K; Bhattacharyya, S; Li, X; Mohan, S; Baylink, D J
2001-10-01
Inbred strains of mice are increasingly being used as an animal model to investigate skeletal disorders relevant to humans. In the bone field, one of the most convenient endpoints for evaluating genetic, physiological, or pharmaceutical perturbations is the use of biochemical markers. To apply biochemical markers in an effective manner, it is of key importance to establish the biological variation and appropriate sampling time. In this study, we evaluate two components: (i) circadian changes, and (ii) longitudinal variation for three serum markers, osteocalcin, C-telopeptide, and skeletal alkaline phosphatase (sALP), using 6-week-old C3H/HeJ (C3H) mice. To study circadian rhythms, the mice were randomly divided into eight groups of 15 mice each. Blood was collected at 3 h intervals, starting at 9:00 A.M. and continuing until 6:00 A.M. the next day. To determine whether circadian rhythm is intrinsically regulated or influenced by restricted food intake, it was also studied after a 12 h fasting period. Serum osteocalcin and C-telopeptide levels were measured by enzyme-linked immunoassay (ELISA) and skeletal alkaline phosphatase by a kinetic assay. The results demonstrated significant circadian variations in osteocalcin and C-telopeptide levels with a peak value between 0900 and 1200 h during daytime and a nadir between 15:00 and 18:00 h. The peak levels of C-telopeptide and osteocalcin were 26%-66% higher as compared with 24 h mean values. The pattern of the circadian variation of C-telopeptide and osteocalcin was similar in female and male animals and was not significantly affected by restricted food intake. The sALP levels were only marginally affected by the circadian rhythm. Longitudinal variations, expressed as coefficient of variation (CV), for osteocalcin, C-telopeptide, and sALP concentrations were 17%, 14%, and 16%, respectively. In addition, the longitudinal variations were not significantly influenced by the time of blood collection in sALP and osteocalcin levels, whereas C-telopeptide levels showed significantly higher within-subject day-to-day variation in morning samples, as compared with blood samples collected in the afternoon. The results highlight the importance of: (i) the timing of sample collection for appropriate interpretation of the bone marker data; and (ii) using the appropriate number of samples based on the variance obtained herein.
Souri, Effat; Rahimi, Aghil; Shabani Ravari, Nazanin; Barazandeh Tehrani, Maliheh
2015-01-01
A mixture of acetaminophen, diphenhydramine hydrochloride and pseudoephedrine hydrochloride is used for the symptomatic treatment of common cold. In this study, a derivative spectrophotometric method based on zero-crossing technique was proposed for simultaneous determination of acetaminophen, diphenhydramine hydrochloride and pseudoephedrine hydrochloride. Determination of these drugs was performed using the 1D value of acetaminophen at 281.5 nm, 2D value of diphenhydramine hydrochloride at 226.0 nm and 4D value of pseudoephedrine hydrochloride at 218.0 nm. The analysis method was linear over the range of 5-50, 0.25-4, and 0.5-5 µg/mL for acetaminophen, diphenhydramine hydrochloride and pseudoephedrine hydrochloride, respectively. The within-day and between-day CV and error values for all three compounds were within an acceptable range (CV<2.2% and error<3%). The developed method was used for simultaneous determination of these drugs in pharmaceutical dosage forms and no interference from excipients was observed. PMID:25901150
Future changes of interannual variation of the Asian summer monsoon precipitation using the CMIP5
NASA Astrophysics Data System (ADS)
Kamizawa, Nozomi; Takahashi, Hiroshi G.
2015-04-01
The Asian summer monsoon (ASM) region is one of the most populated areas in the world. Since the life of people who live in the region and the industry are strongly dependent on the ASM precipitation, it is interested that how it would change under the circumstance of global warming. Many studies have reported that the mean ASM precipitation would increase by comparing the CMIP models' climatology. Although the changes in mean climate are important, the long-term changes of interannual variability in precipitation are also significant. This study investigated the long-term trend of interannual precipitation variation over the ASM region by using 22 CMIP5 models. The RCP4.5 scenario was used. To investigate the long-term trend of the interannual variation of the ASM precipitation, each model data was recreated to 2.5 degree resolution and a running standard deviation for 21 years of June-July-August (JJA) precipitation were calculated. Next, we created the coefficient variation (CV) by dividing the running standard deviation by the mean JJA precipitation. Then we run a Mann-Kendall test for the CV at each grid. There were more areas which were indicated a statistically significant increasing trend than a decreasing trend in the ASM region. 40.6% of the region indicated an increasing trend in the future. On the other hand, 16.8% of the area was indicated to have a decreasing trend. It was also common in the global scale that the there were more areas that indicated an increasing trend than a decreasing trend. We also divided the area into three groups: land, shore and open ocean. In the ASM region, the shore areas particularly had an increasing CV trend. To investigate the long-term changes of the interannual variability of the precipitation and the atmospheric circulation over the ASM region, we conducted a composite analysis for the five wettest and driest years for two periods: the early 21st century (2007-2031) and the late 21st century (2076-2100). The special patterns of the interannual variation of the precipitation and the atmospheric circulation between the two periods had differed only slightly. A positive deviation precipitation band with a cyclonic circulation was recognized from across the Bay of Bengal to the equatorial Northwest Pacific. The none-big-difference of the patterns may suggest that interannual variation in the ASM region would increase not because the pattern changes, but because the pattern's strength gets stronger or its frequency gets higher.
Kawalilak, C E; Johnston, J D; Cooper, D M L; Olszynski, W P; Kontulainen, S A
2016-02-01
Precision errors of cortical bone micro-architecture from high-resolution peripheral quantitative computed tomography (pQCT) ranged from 1 to 16 % and did not differ between automatic or manually modified endocortical contour methods in postmenopausal women or young adults. In postmenopausal women, manually modified contours led to generally higher cortical bone properties when compared to the automated method. First, the objective of the study was to define in vivo precision errors (coefficient of variation root mean square (CV%RMS)) and least significant change (LSC) for cortical bone micro-architecture using two endocortical contouring methods: automatic (AUTO) and manually modified (MOD) in two groups (postmenopausal women and young adults) from high-resolution pQCT (HR-pQCT) scans. Second, it was to compare precision errors and bone outcomes obtained with both methods within and between groups. Using HR-pQCT, we scanned twice the distal radius and tibia of 34 postmenopausal women (mean age ± SD 74 ± 7 years) and 30 young adults (27 ± 9 years). Cortical micro-architecture was determined using AUTO and MOD contour methods. CV%RMS and LSC were calculated. Repeated measures and multivariate ANOVA were used to compare mean CV% and bone outcomes between the methods within and between the groups. Significance was accepted at P < 0.05. CV%RMS ranged from 0.9 to 16.3 %. Within-group precision did not differ between evaluation methods. Compared to young adults, postmenopausal women had better precision for radial cortical porosity (precision difference 9.3 %) and pore volume (7.5 %) with MOD. Young adults had better precision for cortical thickness (0.8 %, MOD) and tibial cortical density (0.2 %, AUTO). In postmenopausal women, MOD resulted in 0.2-54 % higher values for most cortical outcomes, as well as 6-8 % lower radial and tibial cortical BMD and 2 % lower tibial cortical thickness. Results suggest that AUTO and MOD endocortical contour methods provide comparable repeatability. In postmenopausal women, manual modification of endocortical contours led to generally higher cortical bone properties when compared to the automated method, while no between-method differences were observed in young adults.
Wang, Xiao Jun; Saha, Ashwini; Zhang, Xu-Hao
2017-01-01
Currently, two pediatric pneumococcal conjugate vaccines are available in the private market of Malaysia-13-valent pneumococcal conjugate vaccine (PCV13) and pneumococcal polysaccharide and non-typeable Haemophilus influenzae protein D conjugate vaccine (PHiD-CV). This study aimed to evaluate the cost-effectiveness of a universal mass vaccination program with a PHiD-CV 2+1 schedule versus no vaccination or with a PCV13 2+1 schedule in Malaysia. A published Markov cohort model was adapted to evaluate the epidemiological and economic consequences of programs with no vaccination, a PHiD-CV 2+1 schedule or a PCV13 2+1 schedule over a 10-year time horizon. Disease cases, deaths, direct medical costs, quality-adjusted life-years (QALYs) and incremental cost-effectiveness ratios (ICERs) were estimated. Locally published epidemiology and cost data were used whenever possible. Vaccine effectiveness and disutility data were based on the best available published data. All data inputs and assumptions were validated by local clinical and health economics experts. Analyses were conducted from the perspective of the Malaysian government for a birth cohort of 508,774. Costs and QALYs were discounted at 3% per annum. One-way and probabilistic sensitivity analyses were performed. Compared with no vaccination, a PHiD-CV 2+1 program was projected to prevent 1109 invasive pneumococcal disease (IPD), 24,679 pneumonia and 72,940 acute otitis media (AOM) cases and 103 IPD/pneumonia deaths over 10 years, with additional costs and QALYs of United States dollars (USD) 30.9 million and 1084 QALYs, respectively, at an ICER of USD 28,497/QALY. Compared with a PCV13 2+1 program, PHiD-CV 2+1 was projected to result in similar reductions in IPD cases (40 cases more) but significantly fewer AOM cases (30,001 cases less), with cost savings and additional QALYs gained of USD 5.2 million and 116 QALYs, respectively, demonstrating dominance over PCV13. Results were robust to variations in one-way and probabilistic sensitivity analyses. A PHiD-CV 2+1 universal mass vaccination program could substantially reduce pneumococcal disease burden versus no vaccination, and was expected to be cost-effective in Malaysia. A PHiD-CV 2+1 program was also expected to be a dominant choice over a PCV13 2+1 program in Malaysia.
Cormack, C R H; Sudan, S; Addison, R; Keating, J; Sherwood, R A; Ashley, E M C; Howell, Tanya
2006-04-01
The aim of our study was to measure the serum paracetamol concentrations achieved following a single rectal loading dose of 40 mg x kg(-1) in children with chronic liver disease. We recruited 17 children (3-15 years, 10.6-75 kg) undergoing minor surgical procedures under general anesthesia. Paracetamol was administered at the end of surgery and blood samples were taken for analysis at 2, 3, 4, 6 and 8 h postdose. The mean Cmax of 11.4 mg x l(-1) [coefficient of variation (CV) 66%] was achieved at a Tmax of 2.7 h (CV 42%). The relative bioavailability (F) of the suppository formulation was not estimated, but clearance (Cl/F) estimates 0.73 l x kg(-1) x h(-1) (CV 87%) and time-concentration profiles for these children were similar to the normal pediatric population. There are currently no biologic markers available for monitoring possible hepatotoxicity in this cohort of patients with liver disease, but our data suggest that a single-dose suppository is a satisfactory analgesic alternative.
The geometry of proliferating dicot cells.
Korn, R W
2001-02-01
The distributions of cell size and cell cycle duration were studied in two-dimensional expanding plant tissues. Plastic imprints of the leaf epidermis of three dicot plants, jade (Crassula argentae), impatiens (Impatiens wallerana), and the common begonia (Begonia semperflorens) were made and cell outlines analysed. The average, standard deviation and coefficient of variance (CV = 100 x standard deviation/average) of cell size were determined with the CV of mother cells less than the CV for daughter cells and both are less than that for all cells. An equation was devised as a simple description of the probability distribution of sizes for all cells of a tissue. Cell cycle durations as measured in arbitrary time units were determined by reconstructing the initial and final sizes of cells and they collectively give the expected asymmetric bell-shaped probability distribution. Given the features of unequal cell division (an average of 11.6% difference in size of daughter cells) and the size variation of dividing cells, it appears that the range of cell size is more critically regulated than the size of a cell at any particular time.
Faude, Oliver; Hecksteden, Anne; Hammes, Daniel; Schumacher, Franck; Besenius, Eric; Sperlich, Billy; Meyer, Tim
2017-02-01
The maximal lactate steady-state (MLSS) is frequently assessed for prescribing endurance exercise intensity. Knowledge of the intra-individual variability of the MLSS is important for practical application. To date, little is known about the reliability of time-to-exhaustion and physiological responses to exercise at MLSS. Twenty-one healthy men (age, 25.2 (SD 3.3) years; height, 1.83 (0.06) m; body mass, 78.9 (8.9) kg; maximal oxygen uptake, 57.1 (10.7) mL·min -1 ·kg -1 ) performed 1 incremental exercise test, and 2 constant-load tests to determine MLSS intensity. Subsequently, 2 open-end constant-load tests (MLSS 1 and 2) at MLSS intensity (3.0 (0.7) W·kg -1 , 76% (10%) maximal oxygen uptake) were carried out. During the tests, blood lactate concentrations, heart rate, ratings of perceived exertion (RPE), variables of gas exchange, and core body temperature were determined. Time-to-exhaustion was 50.8 (14.0) and 48.2 (16.7) min in MLSS 1 and 2 (mean change: -2.6 (95% confidence interval: -7.8, 2.6)), respectively. The coefficient of variation (CV) was high for time-to-exhaustion (24.6%) and for mean (4.8 (1.2) mmol·L -1 ) and end (5.4 (1.7) mmol·L -1 ) blood lactate concentrations (15.7% and 19.3%). The CV of mean exercise values for all other parameters ranged from 1.4% (core temperature) to 8.3% (ventilation). At termination, the CVs ranged from 0.8% (RPE) to 11.8% (breathing frequency). The low reliability of time-to-exhaustion and blood lactate concentration at MLSS indicates that the precise individual intensity prescription may be challenging. Moreover, the obtained data may serve as reference to allow for the separation of intervention effects from random variation in our sample.
Future Warming Increases Global Maize Yield Variability with Implications for Food Markets
NASA Astrophysics Data System (ADS)
Tigchelaar, M.; Battisti, D. S.; Naylor, R. L.; Ray, D. K.
2017-12-01
If current trends in population growth and dietary shifts continue, the world will need to produce about 70% more food by 2050, while earth's climate is rapidly changing. Rising temperatures in particular are projected to negatively impact agricultural production, as the world's staple crops perform poorly in extreme heat. Theoretical models suggest that as temperatures rise above plants' optimal temperature for performance, not only will mean yields decline rapidly, but the variability of yields will increase, even as interannual variations in climate remain unchanged. Here we use global datasets of maize production and climate variability combined with CMIP5 temperature projections to quantify how yield variability will change in major maize producing countries under 2°C and 4°C of global warming. Maize is the world's most produced crop, and is linked to other staple crops through substitution in consumption and production. We find that in warmer climates - absent any breeding gains in heat tolerance - the Coefficient of Variation (CV) of maize yields increases almost everywhere, to values much larger than present-day. This increase in CV is due both to an increase in the standard deviation of yields, and a decrease in mean yields. In locations where crop failures become the norm under high (4°C) warming (mostly in tropical, low-yield environments), the standard deviation of yields ultimately decreases. The probability that in any given year the most productive areas in the top three maize producing countries (United States, China, Brazil) have simultaneous production losses greater than 10% is virtually zero under present-day climate conditions, but increases to 12% under 2°C warming, and 89% under 4°C warming. This has major implications for global food markets and staple crop prices, affecting especially the 2.5 billion people that comprise the world's poor, who already spend the majority of their disposable income on food and are particularly vulnerable to agricultural price spikes.
Poon, Vickie Wan-kei; Lam, Linda Chiu-wa; Wong, Samuel Yeung-shan
2008-09-01
With the rapid growth of the older population, early detection of cognitive deficits is crucial in slowing down functional deterioration of the elderly persons. To examine the validity and reliability of the Chinese (Cantonese) version of the Hierarchic Dementia Scale (CV-HDS) for Chinese older persons in Hong Kong. The HDS was translated into Cantonese Chinese. The content and cultural validity were evaluated by six expert panel members. Sixty-two participants with diagnosis of dementia were recruited for evaluation. Inter-rater reliability, test-retest reliability, internal consistency and concurrent validity were examined. The CV-HDS demonstrated satisfactory psychometric properties. inter-rater reliability and test-retest reliability were high (alpha=0.89 and alpha=0.94 respectively). High value of Cronbach's alpha (alpha=0.94) demonstrated good internal consistency. The concurrent validity of CV-HDS, through correlation with its scores with that of the Chinese version of Mini Mental Status Examination, was established (ranged from r=0.58 to r=0.78, p<0.01). The CV-HDS is a reliable and valid instrument for assessing severity of cognitive impairment in Cantonese speaking Chinese people with dementia. It facilitates treatment planning to optimize the effects of functional training and rehabilitation.
NASA Astrophysics Data System (ADS)
Niwa, Arisa; Abe, Shinji; Fujita, Naotoshi; Kono, Hidetaka; Odagawa, Tetsuro; Fujita, Yusuke; Tsuchiya, Saki; Kato, Katsuhiko
2015-03-01
Recently myocardial perfusion SPECT imaging acquired using the cardiac focusing-collimator (CF) has been developed in the field of nuclear cardiology. Previously we have investigated the basic characteristics of CF using physical phantoms. This study was aimed at determining the acquisition time for CF that enables to acquire the SPECT images equivalent to those acquired by the conventional method in 201TlCl myocardial perfusion SPECT. In this study, Siemens Symbia T6 was used by setting the torso phantom equipped with the cardiac, pulmonary, and hepatic components. 201TlCl solution were filled in the left ventricular (LV) myocardium and liver. Each of CF, the low energy high resolution collimator (LEHR), and the low medium energy general purpose collimator (LMEGP) was set on the SPECT equipment. Data acquisitions were made by regarding the center of the phantom as the center of the heart in CF at various acquisition times. Acquired data were reconstructed, and the polar maps were created from the reconstructed images. Coefficient of variation (CV) was calculated as the mean counts determined on the polar maps with their standard deviations. When CF was used, CV was lower at longer acquisition times. CV calculated from the polar maps acquired using CF at 2.83 min of acquisition time was equivalent to CV calculated from those acquired using LEHR in a 180°acquisition range at 20 min of acquisition time.
Variability in Wechsler Adult Intelligence Scale-IV subtest performance across age.
Wisdom, Nick M; Mignogna, Joseph; Collins, Robert L
2012-06-01
Normal Wechsler Adult Intelligence Scale (WAIS)-IV performance relative to average normative scores alone can be an oversimplification as this fails to recognize disparate subtest heterogeneity that occurs with increasing age. The purpose of the present study is to characterize the patterns of raw score change and associated variability on WAIS-IV subtests across age groupings. Raw WAIS-IV subtest means and standard deviations for each age group were tabulated from the WAIS-IV normative manual along with the coefficient of variation (CV), a measure of score dispersion calculated by dividing the standard deviation by the mean and multiplying by 100. The CV further informs the magnitude of variability represented by each standard deviation. Raw mean scores predictably decreased across age groups. Increased variability was noted in Perceptual Reasoning and Processing Speed Index subtests, as Block Design, Matrix Reasoning, Picture Completion, Symbol Search, and Coding had CV percentage increases ranging from 56% to 98%. In contrast, Working Memory and Verbal Comprehension subtests were more homogeneous with Digit Span, Comprehension, Information, and Similarities percentage of the mean increases ranging from 32% to 43%. Little change in the CV was noted on Cancellation, Arithmetic, Letter/Number Sequencing, Figure Weights, Visual Puzzles, and Vocabulary subtests (<14%). A thorough understanding of age-related subtest variability will help to identify test limitations as well as further our understanding of cognitive domains which remain relatively steady versus those which steadily decline.
NASA Astrophysics Data System (ADS)
Jacobsen, Benjamin; Yin, Qing-zhu; Moynier, Frederic; Amelin, Yuri; Krot, Alexander N.; Nagashima, Kazuhide; Hutcheon, Ian D.; Palme, Herbert
2008-07-01
The precise knowledge of the initial 26Al/ 27Al ratio [( 26Al/ 27Al) 0] is crucial if we are to use the very first solid objects formed in our Solar System, calcium-aluminum-rich inclusions (CAIs) as the "time zero" age-anchor and guide future work with other short-lived radio-chronometers in the early Solar System, as well as determining the inventory of heat budgets from radioactivities for early planetary differentiation. New high-precision multi-collector inductively-coupled plasma mass spectrometry (MC-ICP-MS) measurements of 27Al/ 24Mg ratios and Mg-isotopic compositions of nine whole-rock CAIs (six mineralogically characterized fragments and three micro-drilled inclusions) from the CV carbonaceous chondrite, Allende yield a well-defined 26Al- 26Mg fossil isochron with an ( 26Al/ 27Al) 0 of (5.23 ± 0.13) × 10 - 5 . Internal mineral isochrons obtained for three of these CAIs ( A44A, AJEF, and A43) are consistent with the whole-rock CAI isochron. The mineral isochron of AJEF with ( 26Al/ 27Al) 0 = (4.96 ± 0.25) × 10 - 5 , anchored to our precisely determined absolute 207Pb- 206Pb age of 4567.60 ± 0.36 Ma for the same mineral separates, reinstate the "canonical" ( 26Al/ 27Al) 0 of 5 × 10 - 5 for the early Solar System. The uncertainty in ( 26Al/ 27Al) 0 corresponds to a maximum time span of ± 20 Ka (thousand years), suggesting that the Allende CAI formation events were culminated within this time span. Although all Allende CAIs studied experienced multistage formation history, including melting and evaporation in the solar nebula and post-crystallization alteration likely on the asteroidal parent body, the 26Al- 26Mg and U-Pb-isotopic systematics of the mineral separates and bulk CAIs behaved largely as closed-system since their formation. Our data do not support the "supra-canonical" 26Al/ 27Al ratio of individual minerals or their mixtures in CV CAIs, suggesting that the supra-canonical 26Al/ 27Al ratio in the CV CAIs may have resulted from post-crystallization inter-mineral redistribution of Mg isotopes within an individual inclusion. This redistribution must be volumetrically minor in order to satisfy the mass balance of the precisely defined bulk CAI and bulk mineral data obtained by MC-ICP-MS. The radiogenic 208Pb*/ 206Pb* ratio obtained as a by-product from the Pb-Pb age dating is used to estimate time-integrated 232Th/ 238U ratio ( κ value) of CAIs. Limited κ variations among the minerals within a single CAI, contrasted by much larger variations among the bulk CAIs, suggest Th/U fractionation occurred prior to crystallization of igneous CAIs. If interpreted as primordial heterogeneity, the κ value can be used to calculate the mean age of the interstellar dust from which the CAIs condensed.
Blendea, Dan; Mansour, Moussa; Shah, Ravi V; Chung, Jeffrey; Nandigam, Veena; Heist, E Kevin; Mela, Theofanie; Reddy, Vivek Y; Manzke, Robert; McPherson, Craig A; Ruskin, Jeremy N; Singh, Jagmeet P
2007-11-15
Standard coronary venous angiography (SCVA) provides a static, fixed projection of the coronary venous (CV) tree. High-speed rotational coronary venous angiography (RCVA) is a novel method of mapping CV anatomy using dynamic, multiangle visualization. The purpose of this study was to assess the value of RCVA during cardiac resynchronization therapy. Digitally acquired rotational CV angiograms from 49 patients (mean age 69 +/- 11 years) who underwent left ventricular lead implantation were analyzed. RCVA, which uses rapid isocentric rotation over a 110 degrees arc, acquiring 120 frames/angiogram, was compared with SCVA, defined as 2 static orthogonal views: right anterior oblique 45 degrees and left anterior oblique 45 degrees . RCVA demonstrated that the posterior vein-to-coronary sinus (CS) angle and the left marginal vein-to-CS angle were misclassified in 5 and 11 patients, respectively, using SCVA. RCVA identified a greater number of second-order tributaries with diameters >1.5 mm than SCVA. The CV branch selected for lead placement was initially identified in 100% of patients using RCVA but in only 74% of patients using SCVA. RCVA showed that the best angiographic view for visualizing the CS and its tributaries differed significantly among different areas of the CV tree and among patients. The area of the CV tree that showed less variability was the CS ostium, which had a fairly constant relation with the spine in shallow right anterior oblique and left anterior oblique projections. In conclusion, RCVA provided a more precise map of CV anatomy and the spatial relation of venous branches. It allowed the identification of fluoroscopic views that could facilitate cannulation of the CS. The final x-ray view displaying the appropriate CV branch for left ventricular lead implantation was often different from the conventional left anterior oblique and right anterior oblique views. RCVA identified the target branch for lead implantation more often than SCVA.