Sample records for variation tv minimization

  1. A new Mumford-Shah total variation minimization based model for sparse-view x-ray computed tomography image reconstruction.

    PubMed

    Chen, Bo; Bian, Zhaoying; Zhou, Xiaohui; Chen, Wensheng; Ma, Jianhua; Liang, Zhengrong

    2018-04-12

    Total variation (TV) minimization for the sparse-view x-ray computer tomography (CT) reconstruction has been widely explored to reduce radiation dose. However, due to the piecewise constant assumption for the TV model, the reconstructed images often suffer from over-smoothness on the image edges. To mitigate this drawback of TV minimization, we present a Mumford-Shah total variation (MSTV) minimization algorithm in this paper. The presented MSTV model is derived by integrating TV minimization and Mumford-Shah segmentation. Subsequently, a penalized weighted least-squares (PWLS) scheme with MSTV is developed for the sparse-view CT reconstruction. For simplicity, the proposed algorithm is named as 'PWLS-MSTV.' To evaluate the performance of the present PWLS-MSTV algorithm, both qualitative and quantitative studies were conducted by using a digital XCAT phantom and a physical phantom. Experimental results show that the present PWLS-MSTV algorithm has noticeable gains over the existing algorithms in terms of noise reduction, contrast-to-ratio measure and edge-preservation.

  2. Adaptive-weighted Total Variation Minimization for Sparse Data toward Low-dose X-ray Computed Tomography Image Reconstruction

    PubMed Central

    Liu, Yan; Ma, Jianhua; Fan, Yi; Liang, Zhengrong

    2012-01-01

    Previous studies have shown that by minimizing the total variation (TV) of the to-be-estimated image with some data and other constraints, a piecewise-smooth X-ray computed tomography (CT) can be reconstructed from sparse-view projection data without introducing noticeable artifacts. However, due to the piecewise constant assumption for the image, a conventional TV minimization algorithm often suffers from over-smoothness on the edges of the resulting image. To mitigate this drawback, we present an adaptive-weighted TV (AwTV) minimization algorithm in this paper. The presented AwTV model is derived by considering the anisotropic edge property among neighboring image voxels, where the associated weights are expressed as an exponential function and can be adaptively adjusted by the local image-intensity gradient for the purpose of preserving the edge details. Inspired by the previously-reported TV-POCS (projection onto convex sets) implementation, a similar AwTV-POCS implementation was developed to minimize the AwTV subject to data and other constraints for the purpose of sparse-view low-dose CT image reconstruction. To evaluate the presented AwTV-POCS algorithm, both qualitative and quantitative studies were performed by computer simulations and phantom experiments. The results show that the presented AwTV-POCS algorithm can yield images with several noticeable gains, in terms of noise-resolution tradeoff plots and full width at half maximum values, as compared to the corresponding conventional TV-POCS algorithm. PMID:23154621

  3. Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

    PubMed

    Liu, Yan; Ma, Jianhua; Fan, Yi; Liang, Zhengrong

    2012-12-07

    Previous studies have shown that by minimizing the total variation (TV) of the to-be-estimated image with some data and other constraints, piecewise-smooth x-ray computed tomography (CT) can be reconstructed from sparse-view projection data without introducing notable artifacts. However, due to the piecewise constant assumption for the image, a conventional TV minimization algorithm often suffers from over-smoothness on the edges of the resulting image. To mitigate this drawback, we present an adaptive-weighted TV (AwTV) minimization algorithm in this paper. The presented AwTV model is derived by considering the anisotropic edge property among neighboring image voxels, where the associated weights are expressed as an exponential function and can be adaptively adjusted by the local image-intensity gradient for the purpose of preserving the edge details. Inspired by the previously reported TV-POCS (projection onto convex sets) implementation, a similar AwTV-POCS implementation was developed to minimize the AwTV subject to data and other constraints for the purpose of sparse-view low-dose CT image reconstruction. To evaluate the presented AwTV-POCS algorithm, both qualitative and quantitative studies were performed by computer simulations and phantom experiments. The results show that the presented AwTV-POCS algorithm can yield images with several notable gains, in terms of noise-resolution tradeoff plots and full-width at half-maximum values, as compared to the corresponding conventional TV-POCS algorithm.

  4. Graph cuts for curvature based image denoising.

    PubMed

    Bae, Egil; Shi, Juan; Tai, Xue-Cheng

    2011-05-01

    Minimization of total variation (TV) is a well-known method for image denoising. Recently, the relationship between TV minimization problems and binary MRF models has been much explored. This has resulted in some very efficient combinatorial optimization algorithms for the TV minimization problem in the discrete setting via graph cuts. To overcome limitations, such as staircasing effects, of the relatively simple TV model, variational models based upon higher order derivatives have been proposed. The Euler's elastica model is one such higher order model of central importance, which minimizes the curvature of all level lines in the image. Traditional numerical methods for minimizing the energy in such higher order models are complicated and computationally complex. In this paper, we will present an efficient minimization algorithm based upon graph cuts for minimizing the energy in the Euler's elastica model, by simplifying the problem to that of solving a sequence of easy graph representable problems. This sequence has connections to the gradient flow of the energy function, and converges to a minimum point. The numerical experiments show that our new approach is more effective in maintaining smooth visual results while preserving sharp features better than TV models.

  5. A limited-angle CT reconstruction method based on anisotropic TV minimization.

    PubMed

    Chen, Zhiqiang; Jin, Xin; Li, Liang; Wang, Ge

    2013-04-07

    This paper presents a compressed sensing (CS)-inspired reconstruction method for limited-angle computed tomography (CT). Currently, CS-inspired CT reconstructions are often performed by minimizing the total variation (TV) of a CT image subject to data consistency. A key to obtaining high image quality is to optimize the balance between TV-based smoothing and data fidelity. In the case of the limited-angle CT problem, the strength of data consistency is angularly varying. For example, given a parallel beam of x-rays, information extracted in the Fourier domain is mostly orthogonal to the direction of x-rays, while little is probed otherwise. However, the TV minimization process is isotropic, suggesting that it is unfit for limited-angle CT. Here we introduce an anisotropic TV minimization method to address this challenge. The advantage of our approach is demonstrated in numerical simulation with both phantom and real CT images, relative to the TV-based reconstruction.

  6. Edge guided image reconstruction in linear scan CT by weighted alternating direction TV minimization.

    PubMed

    Cai, Ailong; Wang, Linyuan; Zhang, Hanming; Yan, Bin; Li, Lei; Xi, Xiaoqi; Li, Jianxin

    2014-01-01

    Linear scan computed tomography (CT) is a promising imaging configuration with high scanning efficiency while the data set is under-sampled and angularly limited for which high quality image reconstruction is challenging. In this work, an edge guided total variation minimization reconstruction (EGTVM) algorithm is developed in dealing with this problem. The proposed method is modeled on the combination of total variation (TV) regularization and iterative edge detection strategy. In the proposed method, the edge weights of intermediate reconstructions are incorporated into the TV objective function. The optimization is efficiently solved by applying alternating direction method of multipliers. A prudential and conservative edge detection strategy proposed in this paper can obtain the true edges while restricting the errors within an acceptable degree. Based on the comparison on both simulation studies and real CT data set reconstructions, EGTVM provides comparable or even better quality compared to the non-edge guided reconstruction and adaptive steepest descent-projection onto convex sets method. With the utilization of weighted alternating direction TV minimization and edge detection, EGTVM achieves fast and robust convergence and reconstructs high quality image when applied in linear scan CT with under-sampled data set.

  7. Hessian-based norm regularization for image restoration with biomedical applications.

    PubMed

    Lefkimmiatis, Stamatios; Bourquard, Aurélien; Unser, Michael

    2012-03-01

    We present nonquadratic Hessian-based regularization methods that can be effectively used for image restoration problems in a variational framework. Motivated by the great success of the total-variation (TV) functional, we extend it to also include second-order differential operators. Specifically, we derive second-order regularizers that involve matrix norms of the Hessian operator. The definition of these functionals is based on an alternative interpretation of TV that relies on mixed norms of directional derivatives. We show that the resulting regularizers retain some of the most favorable properties of TV, i.e., convexity, homogeneity, rotation, and translation invariance, while dealing effectively with the staircase effect. We further develop an efficient minimization scheme for the corresponding objective functions. The proposed algorithm is of the iteratively reweighted least-square type and results from a majorization-minimization approach. It relies on a problem-specific preconditioned conjugate gradient method, which makes the overall minimization scheme very attractive since it can be applied effectively to large images in a reasonable computational time. We validate the overall proposed regularization framework through deblurring experiments under additive Gaussian noise on standard and biomedical images.

  8. Sequentially reweighted TV minimization for CT metal artifact reduction.

    PubMed

    Zhang, Xiaomeng; Xing, Lei

    2013-07-01

    Metal artifact reduction has long been an important topic in x-ray CT image reconstruction. In this work, the authors propose an iterative method that sequentially minimizes a reweighted total variation (TV) of the image and produces substantially artifact-reduced reconstructions. A sequentially reweighted TV minimization algorithm is proposed to fully exploit the sparseness of image gradients (IG). The authors first formulate a constrained optimization model that minimizes a weighted TV of the image, subject to the constraint that the estimated projection data are within a specified tolerance of the available projection measurements, with image non-negativity enforced. The authors then solve a sequence of weighted TV minimization problems where weights used for the next iteration are computed from the current solution. Using the complete projection data, the algorithm first reconstructs an image from which a binary metal image can be extracted. Forward projection of the binary image identifies metal traces in the projection space. The metal-free background image is then reconstructed from the metal-trace-excluded projection data by employing a different set of weights. Each minimization problem is solved using a gradient method that alternates projection-onto-convex-sets and steepest descent. A series of simulation and experimental studies are performed to evaluate the proposed approach. Our study shows that the sequentially reweighted scheme, by altering a single parameter in the weighting function, flexibly controls the sparsity of the IG and reconstructs artifacts-free images in a two-stage process. It successfully produces images with significantly reduced streak artifacts, suppressed noise and well-preserved contrast and edge properties. The sequentially reweighed TV minimization provides a systematic approach for suppressing CT metal artifacts. The technique can also be generalized to other "missing data" problems in CT image reconstruction.

  9. Total Variation with Overlapping Group Sparsity for Image Deblurring under Impulse Noise

    PubMed Central

    Liu, Gang; Huang, Ting-Zhu; Liu, Jun; Lv, Xiao-Guang

    2015-01-01

    The total variation (TV) regularization method is an effective method for image deblurring in preserving edges. However, the TV based solutions usually have some staircase effects. In order to alleviate the staircase effects, we propose a new model for restoring blurred images under impulse noise. The model consists of an ℓ1-fidelity term and a TV with overlapping group sparsity (OGS) regularization term. Moreover, we impose a box constraint to the proposed model for getting more accurate solutions. The solving algorithm for our model is under the framework of the alternating direction method of multipliers (ADMM). We use an inner loop which is nested inside the majorization minimization (MM) iteration for the subproblem of the proposed method. Compared with other TV-based methods, numerical results illustrate that the proposed method can significantly improve the restoration quality, both in terms of peak signal-to-noise ratio (PSNR) and relative error (ReE). PMID:25874860

  10. A feature refinement approach for statistical interior CT reconstruction

    NASA Astrophysics Data System (ADS)

    Hu, Zhanli; Zhang, Yunwan; Liu, Jianbo; Ma, Jianhua; Zheng, Hairong; Liang, Dong

    2016-07-01

    Interior tomography is clinically desired to reduce the radiation dose rendered to patients. In this work, a new statistical interior tomography approach for computed tomography is proposed. The developed design focuses on taking into account the statistical nature of local projection data and recovering fine structures which are lost in the conventional total-variation (TV)—minimization reconstruction. The proposed method falls within the compressed sensing framework of TV minimization, which only assumes that the interior ROI is piecewise constant or polynomial and does not need any additional prior knowledge. To integrate the statistical distribution property of projection data, the objective function is built under the criteria of penalized weighed least-square (PWLS-TV). In the implementation of the proposed method, the interior projection extrapolation based FBP reconstruction is first used as the initial guess to mitigate truncation artifacts and also provide an extended field-of-view. Moreover, an interior feature refinement step, as an important processing operation is performed after each iteration of PWLS-TV to recover the desired structure information which is lost during the TV minimization. Here, a feature descriptor is specifically designed and employed to distinguish structure from noise and noise-like artifacts. A modified steepest descent algorithm is adopted to minimize the associated objective function. The proposed method is applied to both digital phantom and in vivo Micro-CT datasets, and compared to FBP, ART-TV and PWLS-TV. The reconstruction results demonstrate that the proposed method performs better than other conventional methods in suppressing noise, reducing truncated and streak artifacts, and preserving features. The proposed approach demonstrates its potential usefulness for feature preservation of interior tomography under truncated projection measurements.

  11. A feature refinement approach for statistical interior CT reconstruction.

    PubMed

    Hu, Zhanli; Zhang, Yunwan; Liu, Jianbo; Ma, Jianhua; Zheng, Hairong; Liang, Dong

    2016-07-21

    Interior tomography is clinically desired to reduce the radiation dose rendered to patients. In this work, a new statistical interior tomography approach for computed tomography is proposed. The developed design focuses on taking into account the statistical nature of local projection data and recovering fine structures which are lost in the conventional total-variation (TV)-minimization reconstruction. The proposed method falls within the compressed sensing framework of TV minimization, which only assumes that the interior ROI is piecewise constant or polynomial and does not need any additional prior knowledge. To integrate the statistical distribution property of projection data, the objective function is built under the criteria of penalized weighed least-square (PWLS-TV). In the implementation of the proposed method, the interior projection extrapolation based FBP reconstruction is first used as the initial guess to mitigate truncation artifacts and also provide an extended field-of-view. Moreover, an interior feature refinement step, as an important processing operation is performed after each iteration of PWLS-TV to recover the desired structure information which is lost during the TV minimization. Here, a feature descriptor is specifically designed and employed to distinguish structure from noise and noise-like artifacts. A modified steepest descent algorithm is adopted to minimize the associated objective function. The proposed method is applied to both digital phantom and in vivo Micro-CT datasets, and compared to FBP, ART-TV and PWLS-TV. The reconstruction results demonstrate that the proposed method performs better than other conventional methods in suppressing noise, reducing truncated and streak artifacts, and preserving features. The proposed approach demonstrates its potential usefulness for feature preservation of interior tomography under truncated projection measurements.

  12. Accelerating an Ordered-Subset Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction with a Power Factor and Total Variation Minimization.

    PubMed

    Huang, Hsuan-Ming; Hsiao, Ing-Tsung

    2016-01-01

    In recent years, there has been increased interest in low-dose X-ray cone beam computed tomography (CBCT) in many fields, including dentistry, guided radiotherapy and small animal imaging. Despite reducing the radiation dose, low-dose CBCT has not gained widespread acceptance in routine clinical practice. In addition to performing more evaluation studies, developing a fast and high-quality reconstruction algorithm is required. In this work, we propose an iterative reconstruction method that accelerates ordered-subsets (OS) reconstruction using a power factor. Furthermore, we combine it with the total-variation (TV) minimization method. Both simulation and phantom studies were conducted to evaluate the performance of the proposed method. Results show that the proposed method can accelerate conventional OS methods, greatly increase the convergence speed in early iterations. Moreover, applying the TV minimization to the power acceleration scheme can further improve the image quality while preserving the fast convergence rate.

  13. Accelerating an Ordered-Subset Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction with a Power Factor and Total Variation Minimization

    PubMed Central

    Huang, Hsuan-Ming; Hsiao, Ing-Tsung

    2016-01-01

    In recent years, there has been increased interest in low-dose X-ray cone beam computed tomography (CBCT) in many fields, including dentistry, guided radiotherapy and small animal imaging. Despite reducing the radiation dose, low-dose CBCT has not gained widespread acceptance in routine clinical practice. In addition to performing more evaluation studies, developing a fast and high-quality reconstruction algorithm is required. In this work, we propose an iterative reconstruction method that accelerates ordered-subsets (OS) reconstruction using a power factor. Furthermore, we combine it with the total-variation (TV) minimization method. Both simulation and phantom studies were conducted to evaluate the performance of the proposed method. Results show that the proposed method can accelerate conventional OS methods, greatly increase the convergence speed in early iterations. Moreover, applying the TV minimization to the power acceleration scheme can further improve the image quality while preserving the fast convergence rate. PMID:27073853

  14. WE-G-207-04: Non-Local Total-Variation (NLTV) Combined with Reweighted L1-Norm for Compressed Sensing Based CT Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, H; Chen, J; Pouliot, J

    2015-06-15

    Purpose: Compressed sensing (CS) has been used for CT (4DCT/CBCT) reconstruction with few projections to reduce dose of radiation. Total-variation (TV) in L1-minimization (min.) with local information is the prevalent technique in CS, while it can be prone to noise. To address the problem, this work proposes to apply a new image processing technique, called non-local TV (NLTV), to CS based CT reconstruction, and incorporate reweighted L1-norm into it for more precise reconstruction. Methods: TV minimizes intensity variations by considering two local neighboring voxels, which can be prone to noise, possibly damaging the reconstructed CT image. NLTV, contrarily, utilizes moremore » global information by computing a weight function of current voxel relative to surrounding search area. In fact, it might be challenging to obtain an optimal solution due to difficulty in defining the weight function with appropriate parameters. Introducing reweighted L1-min., designed for approximation to ideal L0-min., can reduce the dependence on defining the weight function, therefore improving accuracy of the solution. This work implemented the NLTV combined with reweighted L1-min. by Split Bregman Iterative method. For evaluation, a noisy digital phantom and a pelvic CT images are employed to compare the quality of images reconstructed by TV, NLTV and reweighted NLTV. Results: In both cases, conventional and reweighted NLTV outperform TV min. in signal-to-noise ratio (SNR) and root-mean squared errors of the reconstructed images. Relative to conventional NLTV, NLTV with reweighted L1-norm was able to slightly improve SNR, while greatly increasing the contrast between tissues due to additional iterative reweighting process. Conclusion: NLTV min. can provide more precise compressed sensing based CT image reconstruction by incorporating the reweighted L1-norm, while maintaining greater robustness to the noise effect than TV min.« less

  15. A compressed sensing based approach on Discrete Algebraic Reconstruction Technique.

    PubMed

    Demircan-Tureyen, Ezgi; Kamasak, Mustafa E

    2015-01-01

    Discrete tomography (DT) techniques are capable of computing better results, even using less number of projections than the continuous tomography techniques. Discrete Algebraic Reconstruction Technique (DART) is an iterative reconstruction method proposed to achieve this goal by exploiting a prior knowledge on the gray levels and assuming that the scanned object is composed from a few different densities. In this paper, DART method is combined with an initial total variation minimization (TvMin) phase to ensure a better initial guess and extended with a segmentation procedure in which the threshold values are estimated from a finite set of candidates to minimize both the projection error and the total variation (TV) simultaneously. The accuracy and the robustness of the algorithm is compared with the original DART by the simulation experiments which are done under (1) limited number of projections, (2) limited view problem and (3) noisy projections conditions.

  16. Total variation iterative constraint algorithm for limited-angle tomographic reconstruction of non-piecewise-constant structures

    NASA Astrophysics Data System (ADS)

    Krauze, W.; Makowski, P.; Kujawińska, M.

    2015-06-01

    Standard tomographic algorithms applied to optical limited-angle tomography result in the reconstructions that have highly anisotropic resolution and thus special algorithms are developed. State of the art approaches utilize the Total Variation (TV) minimization technique. These methods give very good results but are applicable to piecewise constant structures only. In this paper, we propose a novel algorithm for 3D limited-angle tomography - Total Variation Iterative Constraint method (TVIC) which enhances the applicability of the TV regularization to non-piecewise constant samples, like biological cells. This approach consists of two parts. First, the TV minimization is used as a strong regularizer to create a sharp-edged image converted to a 3D binary mask which is then iteratively applied in the tomographic reconstruction as a constraint in the object domain. In the present work we test the method on a synthetic object designed to mimic basic structures of a living cell. For simplicity, the test reconstructions were performed within the straight-line propagation model (SIRT3D solver from the ASTRA Tomography Toolbox), but the strategy is general enough to supplement any algorithm for tomographic reconstruction that supports arbitrary geometries of plane-wave projection acquisition. This includes optical diffraction tomography solvers. The obtained reconstructions present resolution uniformity and general shape accuracy expected from the TV regularization based solvers, but keeping the smooth internal structures of the object at the same time. Comparison between three different patterns of object illumination arrangement show very small impact of the projection acquisition geometry on the image quality.

  17. Limited data tomographic image reconstruction via dual formulation of total variation minimization

    NASA Astrophysics Data System (ADS)

    Jang, Kwang Eun; Sung, Younghun; Lee, Kangeui; Lee, Jongha; Cho, Seungryong

    2011-03-01

    The X-ray mammography is the primary imaging modality for breast cancer screening. For the dense breast, however, the mammogram is usually difficult to read due to tissue overlap problem caused by the superposition of normal tissues. The digital breast tomosynthesis (DBT) that measures several low dose projections over a limited angle range may be an alternative modality for breast imaging, since it allows the visualization of the cross-sectional information of breast. The DBT, however, may suffer from the aliasing artifact and the severe noise corruption. To overcome these problems, a total variation (TV) regularized statistical reconstruction algorithm is presented. Inspired by the dual formulation of TV minimization in denoising and deblurring problems, we derived a gradient-type algorithm based on statistical model of X-ray tomography. The objective function is comprised of a data fidelity term derived from the statistical model and a TV regularization term. The gradient of the objective function can be easily calculated using simple operations in terms of auxiliary variables. After a descending step, the data fidelity term is renewed in each iteration. Since the proposed algorithm can be implemented without sophisticated operations such as matrix inverse, it provides an efficient way to include the TV regularization in the statistical reconstruction method, which results in a fast and robust estimation for low dose projections over the limited angle range. Initial tests with an experimental DBT system confirmed our finding.

  18. Low Dose PET Image Reconstruction with Total Variation Using Alternating Direction Method.

    PubMed

    Yu, Xingjian; Wang, Chenye; Hu, Hongjie; Liu, Huafeng

    2016-01-01

    In this paper, a total variation (TV) minimization strategy is proposed to overcome the problem of sparse spatial resolution and large amounts of noise in low dose positron emission tomography (PET) imaging reconstruction. Two types of objective function were established based on two statistical models of measured PET data, least-square (LS) TV for the Gaussian distribution and Poisson-TV for the Poisson distribution. To efficiently obtain high quality reconstructed images, the alternating direction method (ADM) is used to solve these objective functions. As compared with the iterative shrinkage/thresholding (IST) based algorithms, the proposed ADM can make full use of the TV constraint and its convergence rate is faster. The performance of the proposed approach is validated through comparisons with the expectation-maximization (EM) method using synthetic and experimental biological data. In the comparisons, the results of both LS-TV and Poisson-TV are taken into consideration to find which models are more suitable for PET imaging, in particular low-dose PET. To evaluate the results quantitatively, we computed bias, variance, and the contrast recovery coefficient (CRC) and drew profiles of the reconstructed images produced by the different methods. The results show that both Poisson-TV and LS-TV can provide a high visual quality at a low dose level. The bias and variance of the proposed LS-TV and Poisson-TV methods are 20% to 74% less at all counting levels than those of the EM method. Poisson-TV gives the best performance in terms of high-accuracy reconstruction with the lowest bias and variance as compared to the ground truth (14.3% less bias and 21.9% less variance). In contrast, LS-TV gives the best performance in terms of the high contrast of the reconstruction with the highest CRC.

  19. Low Dose PET Image Reconstruction with Total Variation Using Alternating Direction Method

    PubMed Central

    Yu, Xingjian; Wang, Chenye; Hu, Hongjie; Liu, Huafeng

    2016-01-01

    In this paper, a total variation (TV) minimization strategy is proposed to overcome the problem of sparse spatial resolution and large amounts of noise in low dose positron emission tomography (PET) imaging reconstruction. Two types of objective function were established based on two statistical models of measured PET data, least-square (LS) TV for the Gaussian distribution and Poisson-TV for the Poisson distribution. To efficiently obtain high quality reconstructed images, the alternating direction method (ADM) is used to solve these objective functions. As compared with the iterative shrinkage/thresholding (IST) based algorithms, the proposed ADM can make full use of the TV constraint and its convergence rate is faster. The performance of the proposed approach is validated through comparisons with the expectation-maximization (EM) method using synthetic and experimental biological data. In the comparisons, the results of both LS-TV and Poisson-TV are taken into consideration to find which models are more suitable for PET imaging, in particular low-dose PET. To evaluate the results quantitatively, we computed bias, variance, and the contrast recovery coefficient (CRC) and drew profiles of the reconstructed images produced by the different methods. The results show that both Poisson-TV and LS-TV can provide a high visual quality at a low dose level. The bias and variance of the proposed LS-TV and Poisson-TV methods are 20% to 74% less at all counting levels than those of the EM method. Poisson-TV gives the best performance in terms of high-accuracy reconstruction with the lowest bias and variance as compared to the ground truth (14.3% less bias and 21.9% less variance). In contrast, LS-TV gives the best performance in terms of the high contrast of the reconstruction with the highest CRC. PMID:28005929

  20. Imaging techniques for evaluation of the uterine cavity and endometrium in premenopausal patients before minimally invasive surgery.

    PubMed

    Dueholm, Margit; Lundorf, Erik; Olesen, Frede

    2002-06-01

    A literature review compared the diagnostic effectiveness and accuracy of transvaginal sonography (TVS) hysterosonographic examination (HSE), hysteroscopy (HY), and magnetic resonance imaging (MRI) in abnormalities of the uterine cavity and endometrium in premenopausal patients referred to surgery and women with abnormal uterine bleeding. The studies varied much in terms of patient selection, number of observers, blinding and experience of observers, and definition of abnormality criteria. The diagnostic effectiveness of the techniques reviewed varied: TVS only reached intermediate quality levels as a diagnostic tool for exclusion of uterine cavity abnormalities and no data support that MRI, TVS, HY, or HSE may exclude hyperplasia without concomitant endometrial sampling. HY and HSE were equally effective and apparently outperformed TVS, especially for identification of polyps. However, all techniques carried a significant number of false positive results. MRI does not satisfy current diagnostic demands for detection of endometrial abnormalities, but it is sufficiently accurate for submucous myoma (SM) evaluation. TVS, HSE, and HY carry much observer variation as opposed to MRI. In experienced hands TVS should be a first choice modality, but its precision and consistency fall short of current needs and it should therefore be supplemented by other techniques. HSE or HY performed by experienced clinicians should be used as supplements to TVS for exclusion of polyps. MRI can be recommended as the first choice modality for exact evaluation of SM uterine in-growth before advanced minimal invasive treatment of myomas. Clinicians should be aware that modern imaging techniques may yield highly idiosyncratic results when used by inexperienced staff, and efforts should be made to reduce such observer variation. Obstetricians & Gynecologists, Family Physicians. After completion of this article, the reader will be able to describe the diagnostic strengths and weaknesses of the various diagnostic tests in the evaluation of abnormal uterine bleeding and to compare the accuracy of each test to the others.

  1. Low Dose CT Reconstruction via Edge-preserving Total Variation Regularization

    PubMed Central

    Tian, Zhen; Jia, Xun; Yuan, Kehong; Pan, Tinsu; Jiang, Steve B.

    2014-01-01

    High radiation dose in CT scans increases a lifetime risk of cancer and has become a major clinical concern. Recently, iterative reconstruction algorithms with Total Variation (TV) regularization have been developed to reconstruct CT images from highly undersampled data acquired at low mAs levels in order to reduce the imaging dose. Nonetheless, the low contrast structures tend to be smoothed out by the TV regularization, posing a great challenge for the TV method. To solve this problem, in this work we develop an iterative CT reconstruction algorithm with edge-preserving TV regularization to reconstruct CT images from highly undersampled data obtained at low mAs levels. The CT image is reconstructed by minimizing an energy consisting of an edge-preserving TV norm and a data fidelity term posed by the x-ray projections. The edge-preserving TV term is proposed to preferentially perform smoothing only on non-edge part of the image in order to better preserve the edges, which is realized by introducing a penalty weight to the original total variation norm. During the reconstruction process, the pixels at edges would be gradually identified and given small penalty weight. Our iterative algorithm is implemented on GPU to improve its speed. We test our reconstruction algorithm on a digital NCAT phantom, a physical chest phantom, and a Catphan phantom. Reconstruction results from a conventional FBP algorithm and a TV regularization method without edge preserving penalty are also presented for comparison purpose. The experimental results illustrate that both TV-based algorithm and our edge-preserving TV algorithm outperform the conventional FBP algorithm in suppressing the streaking artifacts and image noise under the low dose context. Our edge-preserving algorithm is superior to the TV-based algorithm in that it can preserve more information of low contrast structures and therefore maintain acceptable spatial resolution. PMID:21860076

  2. Fractional-order TV-L2 model for image denoising

    NASA Astrophysics Data System (ADS)

    Chen, Dali; Sun, Shenshen; Zhang, Congrong; Chen, YangQuan; Xue, Dingyu

    2013-10-01

    This paper proposes a new fractional order total variation (TV) denoising method, which provides a much more elegant and effective way of treating problems of the algorithm implementation, ill-posed inverse, regularization parameter selection and blocky effect. Two fractional order TV-L2 models are constructed for image denoising. The majorization-minimization (MM) algorithm is used to decompose these two complex fractional TV optimization problems into a set of linear optimization problems which can be solved by the conjugate gradient algorithm. The final adaptive numerical procedure is given. Finally, we report experimental results which show that the proposed methodology avoids the blocky effect and achieves state-of-the-art performance. In addition, two medical image processing experiments are presented to demonstrate the validity of the proposed methodology.

  3. Structure-adaptive CBCT reconstruction using weighted total variation and Hessian penalties

    PubMed Central

    Shi, Qi; Sun, Nanbo; Sun, Tao; Wang, Jing; Tan, Shan

    2016-01-01

    The exposure of normal tissues to high radiation during cone-beam CT (CBCT) imaging increases the risk of cancer and genetic defects. Statistical iterative algorithms with the total variation (TV) penalty have been widely used for low dose CBCT reconstruction, with state-of-the-art performance in suppressing noise and preserving edges. However, TV is a first-order penalty and sometimes leads to the so-called staircase effect, particularly over regions with smooth intensity transition in the reconstruction images. A second-order penalty known as the Hessian penalty was recently used to replace TV to suppress the staircase effect in CBCT reconstruction at the cost of slightly blurring object edges. In this study, we proposed a new penalty, the TV-H, which combines TV and Hessian penalties for CBCT reconstruction in a structure-adaptive way. The TV-H penalty automatically differentiates the edges, gradual transition and uniform local regions within an image using the voxel gradient, and adaptively weights TV and Hessian according to the local image structures in the reconstruction process. Our proposed penalty retains the benefits of TV, including noise suppression and edge preservation. It also maintains the structures in regions with gradual intensity transition more successfully. A majorization-minimization (MM) approach was designed to optimize the objective energy function constructed with the TV-H penalty. The MM approach employed a quadratic upper bound of the original objective function, and the original optimization problem was changed to a series of quadratic optimization problems, which could be efficiently solved using the Gauss-Seidel update strategy. We tested the reconstruction algorithm on two simulated digital phantoms and two physical phantoms. Our experiments indicated that the TV-H penalty visually and quantitatively outperformed both TV and Hessian penalties. PMID:27699100

  4. Structure-adaptive CBCT reconstruction using weighted total variation and Hessian penalties.

    PubMed

    Shi, Qi; Sun, Nanbo; Sun, Tao; Wang, Jing; Tan, Shan

    2016-09-01

    The exposure of normal tissues to high radiation during cone-beam CT (CBCT) imaging increases the risk of cancer and genetic defects. Statistical iterative algorithms with the total variation (TV) penalty have been widely used for low dose CBCT reconstruction, with state-of-the-art performance in suppressing noise and preserving edges. However, TV is a first-order penalty and sometimes leads to the so-called staircase effect, particularly over regions with smooth intensity transition in the reconstruction images. A second-order penalty known as the Hessian penalty was recently used to replace TV to suppress the staircase effect in CBCT reconstruction at the cost of slightly blurring object edges. In this study, we proposed a new penalty, the TV-H, which combines TV and Hessian penalties for CBCT reconstruction in a structure-adaptive way. The TV-H penalty automatically differentiates the edges, gradual transition and uniform local regions within an image using the voxel gradient, and adaptively weights TV and Hessian according to the local image structures in the reconstruction process. Our proposed penalty retains the benefits of TV, including noise suppression and edge preservation. It also maintains the structures in regions with gradual intensity transition more successfully. A majorization-minimization (MM) approach was designed to optimize the objective energy function constructed with the TV-H penalty. The MM approach employed a quadratic upper bound of the original objective function, and the original optimization problem was changed to a series of quadratic optimization problems, which could be efficiently solved using the Gauss-Seidel update strategy. We tested the reconstruction algorithm on two simulated digital phantoms and two physical phantoms. Our experiments indicated that the TV-H penalty visually and quantitatively outperformed both TV and Hessian penalties.

  5. Improving IMRT delivery efficiency with reweighted L1-minimization for inverse planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Hojin; Becker, Stephen; Lee, Rena

    2013-07-15

    Purpose: This study presents an improved technique to further simplify the fluence-map in intensity modulated radiation therapy (IMRT) inverse planning, thereby reducing plan complexity and improving delivery efficiency, while maintaining the plan quality.Methods: First-order total-variation (TV) minimization (min.) based on L1-norm has been proposed to reduce the complexity of fluence-map in IMRT by generating sparse fluence-map variations. However, with stronger dose sparing to the critical structures, the inevitable increase in the fluence-map complexity can lead to inefficient dose delivery. Theoretically, L0-min. is the ideal solution for the sparse signal recovery problem, yet practically intractable due to its nonconvexity of themore » objective function. As an alternative, the authors use the iteratively reweighted L1-min. technique to incorporate the benefits of the L0-norm into the tractability of L1-min. The weight multiplied to each element is inversely related to the magnitude of the corresponding element, which is iteratively updated by the reweighting process. The proposed penalizing process combined with TV min. further improves sparsity in the fluence-map variations, hence ultimately enhancing the delivery efficiency. To validate the proposed method, this work compares three treatment plans obtained from quadratic min. (generally used in clinic IMRT), conventional TV min., and our proposed reweighted TV min. techniques, implemented by a large-scale L1-solver (template for first-order conic solver), for five patient clinical data. Criteria such as conformation number (CN), modulation index (MI), and estimated treatment time are employed to assess the relationship between the plan quality and delivery efficiency.Results: The proposed method yields simpler fluence-maps than the quadratic and conventional TV based techniques. To attain a given CN and dose sparing to the critical organs for 5 clinical cases, the proposed method reduces the number of segments by 10-15 and 30-35, relative to TV min. and quadratic min. based plans, while MIs decreases by about 20%-30% and 40%-60% over the plans by two existing techniques, respectively. With such conditions, the total treatment time of the plans obtained from our proposed method can be reduced by 12-30 s and 30-80 s mainly due to greatly shorter multileaf collimator (MLC) traveling time in IMRT step-and-shoot delivery.Conclusions: The reweighted L1-minimization technique provides a promising solution to simplify the fluence-map variations in IMRT inverse planning. It improves the delivery efficiency by reducing the entire segments and treatment time, while maintaining the plan quality in terms of target conformity and critical structure sparing.« less

  6. Minimizing the Risk of Infection and Bleeding at Trans-Vaginal Ultrasound-Guided Ovum Pick-up: Results of a Prospective Web-Based World-Wide Survey.

    PubMed

    Bhandari, Harish; Agrawal, Rina; Weissman, Ariel; Shoham, Gon; Leong, Milton; Shoham, Zeev

    2015-12-01

    The objective of this study was to identify clinical practices worldwide, which would help in recognizing women at risk of excessive bleeding or of developing pelvic infection following trans-vaginal ovum pick-up (TV-OPU), measures taken to minimize risks and their management. A prospective, web-based questionnaire with distinct questions related to the practice of TV-OPU. A total of 155 units from 55 countries performing 97,200 IVF cycles annually responded to this web-based survey. A majority (65 %) responded that they would routinely carry out full blood count, while 35 % performed coagulation profile. Less than a third agreed screening women for vaginal infections. About a third used both sterile water and antiseptic to minimize ascending infection, and 52 % used antibiotics for prophylaxis. Doppler ultrasound was routinely used by 20 % of clinicians. 73 % of the clinicians preferred conservative management as their first line management for patients diagnosed with intra-abdominal bleeding. The study has identified a wide variation in the practices of minimizing infection and bleeding complications. The dearth of good quality evidence may be responsible for the lack of published guidelines, and therefore a lack of consensus on the optimum practice for minimizing the risk of infection and bleeding during TV-OPU.

  7. Single image super-resolution based on compressive sensing and improved TV minimization sparse recovery

    NASA Astrophysics Data System (ADS)

    Vishnukumar, S.; Wilscy, M.

    2017-12-01

    In this paper, we propose a single image Super-Resolution (SR) method based on Compressive Sensing (CS) and Improved Total Variation (TV) Minimization Sparse Recovery. In the CS framework, low-resolution (LR) image is treated as the compressed version of high-resolution (HR) image. Dictionary Training and Sparse Recovery are the two phases of the method. K-Singular Value Decomposition (K-SVD) method is used for dictionary training and the dictionary represents HR image patches in a sparse manner. Here, only the interpolated version of the LR image is used for training purpose and thereby the structural self similarity inherent in the LR image is exploited. In the sparse recovery phase the sparse representation coefficients with respect to the trained dictionary for LR image patches are derived using Improved TV Minimization method. HR image can be reconstructed by the linear combination of the dictionary and the sparse coefficients. The experimental results show that the proposed method gives better results quantitatively as well as qualitatively on both natural and remote sensing images. The reconstructed images have better visual quality since edges and other sharp details are preserved.

  8. Reconstruction of sparse-view X-ray computed tomography using adaptive iterative algorithms.

    PubMed

    Liu, Li; Lin, Weikai; Jin, Mingwu

    2015-01-01

    In this paper, we propose two reconstruction algorithms for sparse-view X-ray computed tomography (CT). Treating the reconstruction problems as data fidelity constrained total variation (TV) minimization, both algorithms adapt the alternate two-stage strategy: projection onto convex sets (POCS) for data fidelity and non-negativity constraints and steepest descent for TV minimization. The novelty of this work is to determine iterative parameters automatically from data, thus avoiding tedious manual parameter tuning. In TV minimization, the step sizes of steepest descent are adaptively adjusted according to the difference from POCS update in either the projection domain or the image domain, while the step size of algebraic reconstruction technique (ART) in POCS is determined based on the data noise level. In addition, projection errors are used to compare with the error bound to decide whether to perform ART so as to reduce computational costs. The performance of the proposed methods is studied and evaluated using both simulated and physical phantom data. Our methods with automatic parameter tuning achieve similar, if not better, reconstruction performance compared to a representative two-stage algorithm. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Nonlocal variational model and filter algorithm to remove multiplicative noise

    NASA Astrophysics Data System (ADS)

    Chen, Dai-Qiang; Zhang, Hui; Cheng, Li-Zhi

    2010-07-01

    The nonlocal (NL) means filter proposed by Buades, Coll, and Morel (SIAM Multiscale Model. Simul. 4(2), 490-530, 2005), which makes full use of the redundancy information in images, has shown to be very efficient for image denoising with Gauss noise added. On the basis of the NL method and a striver to minimize the conditional mean-square error, we design a NL means filter to remove multiplicative noise, and combining the NL filter to regularity method, we propose a NL total variational (TV) model and present a fast iterated algorithm for it. Experiments demonstrate that our algorithm is better than TV method; it is superior in preserving small structures and textures and can obtain an improvement in peak signal-to-noise ratio.

  10. Investigation into image quality difference between total variation and nonlinear sparsifying transform based compressed sensing

    NASA Astrophysics Data System (ADS)

    Dong, Jian; Kudo, Hiroyuki

    2017-03-01

    Compressed sensing (CS) is attracting growing concerns in sparse-view computed tomography (CT) image reconstruction. The most standard approach of CS is total variation (TV) minimization. However, images reconstructed by TV usually suffer from distortions, especially in reconstruction of practical CT images, in forms of patchy artifacts, improper serrate edges and loss of image textures. Most existing CS approaches including TV achieve image quality improvement by applying linear transforms to object image, but linear transforms usually fail to take discontinuities into account, such as edges and image textures, which is considered to be the key reason for image distortions. Actually, discussions on nonlinear filter based image processing has a long history, leading us to clarify that the nonlinear filters yield better results compared to linear filters in image processing task such as denoising. Median root prior was first utilized by Alenius as nonlinear transform in CT image reconstruction, with significant gains obtained. Subsequently, Zhang developed the application of nonlocal means-based CS. A fact is gradually becoming clear that the nonlinear transform based CS has superiority in improving image quality compared with the linear transform based CS. However, it has not been clearly concluded in any previous paper within the scope of our knowledge. In this work, we investigated the image quality differences between the conventional TV minimization and nonlinear sparsifying transform based CS, as well as image quality differences among different nonlinear sparisying transform based CSs in sparse-view CT image reconstruction. Additionally, we accelerated the implementation of nonlinear sparsifying transform based CS algorithm.

  11. SU-F-18C-13: Low-Dose X-Ray CT Reconstruction Using a Hybrid First-Order Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, L; Lin, W; Jin, M

    2014-06-15

    Purpose: To develop a novel reconstruction method for X-ray CT that can lead to accurate reconstruction at significantly reduced dose levels combining low X-ray incident intensity and few views of projection data. Methods: The noise nature of the projection data at low X-ray incident intensity was modeled and accounted by the weighted least-squares (WLS) criterion. The total variation (TV) penalty was used to mitigate artifacts caused by few views of data. The first order primal-dual (FOPD) algorithm was used to minimize TV in image domain, which avoided the difficulty of the non-smooth objective function. The TV penalized WLS reconstruction wasmore » achieved by alternated FOPD TV minimization and projection onto convex sets (POCS) for data fidelity constraints. The proposed FOPD-POCS method was evaluated using the FORBILD jaw phantom and the real cadaver head CT data. Results: The quantitative measures, root mean square error (RMSE) and contrast-to-noise ratio (CNR), demonstrate the superior denoising capability of WLS over LS-based TV iterative reconstruction. The improvement of RMSE (WLS vs. LS) is 15%∼21% and that of CNR is 17%∼72% when the incident counts per ray are ranged from 1×10{sup 5} to 1×10{sup 3}. In addition, the TV regularization can accurately reconstruct images from about 50 views of the jaw phantom. The FOPD-POCS reconstruction reveals more structural details and suffers fewer artifacts in both the phantom and real head images. The FOPD-POCS method also shows fast convergence at low X-ray incident intensity. Conclusion: The new hybrid FOPD-POCS method, based on TV penalized WLS, yields excellent image quality when the incident X-ray intensity is low and the projection views are limited. The reconstruction is computationally efficient since the FOPD minimization of TV is applied only in the image domain. The characteristics of FOPD-POCS can be exploited to significantly reduce radiation dose of X-ray CT without compromising accuracy for diagnosis or treatment planning.« less

  12. The estimation of the thyroid volume before surgery--an important prerequisite for minimally invasive thyroidectomy.

    PubMed

    Ruggieri, M; Fumarola, A; Straniero, A; Maiuolo, A; Coletta, I; Veltri, A; Di Fiore, A; Trimboli, P; Gargiulo, P; Genderini, M; D'Armiento, M

    2008-09-01

    Actually, thyroid volume >25 ml, obtained by preoperative ultrasound evaluation, is a very important exclusion criteria for minimally invasive thyroidectomy. So far, among different imaging techniques, two-dimensional ultrasonography has become the more accepted method for the assessment of thyroid volume (US-TV). The aims of this study were: (1) to estimate the preoperative thyroid volume in patients undergoing minimally invasive total thyroidectomy using a mathematical formula and (2) to verify its validity by comparing it with the postsurgical TV (PS-TV). In 53 patients who underwent minimally invasive total thyroidectomy (from January 2003 to December 2007), US-TV, obtained by ellipsoid volume formula, was compared to PS-TV determined by the Archimedes' principle. A mathematical formula able to predict the TV from the US-TV was applied in 34 cases in the last 2 years. Mean US-TV (14.4 +/- 5.9 ml) was significantly lower than mean PS-TV (21.7 +/- 10.3 ml). This underestimation was related to gland multinodularity and/or nodular involvement of the isthmus. A mathematical formula to reduce US-TV underestimation and predict the real TV was developed using a linear model. Mean predicted TV (16.8 +/- 3.7 ml) perfectly matched mean PS-TV, underestimating PS-TV in 19% of cases. We verified the accuracy of this mathematical model in patients' eligibility for minimally invasive total thyroidectomy, and we demonstrated that a predicted TV <25 ml was confirmed post-surgery in 94% of cases. We demonstrated that using a linear model, it is possible to predict from US the PS-TV with high accuracy. In fact, the mean predicted TV perfectly matched the mean PS-TV in all cases. In particular, the percentage of cases in which the predicted TV perfectly matched the PS-TV increases from 23%, estimated by US, to 43%. Moreover, the percentage of TV underestimation was reduced from 77% to 19%, as well as the range of the disagreement from up to 200% to 80%. This study shows that two-dimensional US can provide the accurate estimation of thyroid volume but that it can be improved by a mathematical model. This may contribute to a more appropriate surgical management of thyroid diseases.

  13. Contrast adaptive total p-norm variation minimization approach to CT reconstruction for artifact reduction in reduced-view brain perfusion CT

    NASA Astrophysics Data System (ADS)

    Kim, Chang-Won; Kim, Jong-Hyo

    2011-03-01

    Perfusion CT (PCT) examinations are getting more frequently used for diagnosis of acute brain diseases such as hemorrhage and infarction, because the functional map images it produces such as regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV), and mean transit time (MTT) may provide critical information in the emergency work-up of patient care. However, a typical PCT scans the same slices several tens of times after injection of contrast agent, which leads to much increased radiation dose and is inevitability of growing concern for radiation-induced cancer risk. Reducing the number of views in projection in combination of TV minimization reconstruction technique is being regarded as an option for radiation reduction. However, reconstruction artifacts due to insufficient number of X-ray projections become problematic especially when high contrast enhancement signals are present or patient's motion occurred. In this study, we present a novel reconstruction technique using contrast-adaptive TpV minimization that can reduce reconstruction artifacts effectively by using different p-norms in high contrast and low contrast objects. In the proposed method, high contrast components are first reconstructed using thresholded projection data and low p-norm total variation to reflect sparseness in both projection and reconstruction spaces. Next, projection data are modified to contain only low contrast objects by creating projection data of reconstructed high contrast components and subtracting them from original projection data. Then, the low contrast projection data are reconstructed by using relatively high p-norm TV minimization technique, and are combined with the reconstructed high contrast component images to produce final reconstructed images. The proposed algorithm was applied to numerical phantom and a clinical data set of brain PCT exam, and the resultant images were compared with those using filtered back projection (FBP) and conventional TV reconstruction algorithm. Our results show the potential of the proposed algorithm for image quality improvement, which in turn may lead to dose reduction.

  14. Robust dynamic myocardial perfusion CT deconvolution using adaptive-weighted tensor total variation regularization

    NASA Astrophysics Data System (ADS)

    Gong, Changfei; Zeng, Dong; Bian, Zhaoying; Huang, Jing; Zhang, Xinyu; Zhang, Hua; Lu, Lijun; Feng, Qianjin; Liang, Zhengrong; Ma, Jianhua

    2016-03-01

    Dynamic myocardial perfusion computed tomography (MPCT) is a promising technique for diagnosis and risk stratification of coronary artery disease by assessing the myocardial perfusion hemodynamic maps (MPHM). Meanwhile, the repeated scanning of the same region results in a relatively large radiation dose to patients potentially. In this work, we present a robust MPCT deconvolution algorithm with adaptive-weighted tensor total variation regularization to estimate residue function accurately under the low-dose context, which is termed `MPD-AwTTV'. More specifically, the AwTTV regularization takes into account the anisotropic edge property of the MPCT images compared with the conventional total variation (TV) regularization, which can mitigate the drawbacks of TV regularization. Subsequently, an effective iterative algorithm was adopted to minimize the associative objective function. Experimental results on a modified XCAT phantom demonstrated that the present MPD-AwTTV algorithm outperforms and is superior to other existing deconvolution algorithms in terms of noise-induced artifacts suppression, edge details preservation and accurate MPHM estimation.

  15. Accurate low-dose iterative CT reconstruction from few projections by Generalized Anisotropic Total Variation minimization for industrial CT.

    PubMed

    Debatin, Maurice; Hesser, Jürgen

    2015-01-01

    Reducing the amount of time for data acquisition and reconstruction in industrial CT decreases the operation time of the X-ray machine and therefore increases the sales. This can be achieved by reducing both, the dose and the pulse length of the CT system and the number of projections for the reconstruction, respectively. In this paper, a novel generalized Anisotropic Total Variation regularization for under-sampled, low-dose iterative CT reconstruction is discussed and compared to the standard methods, Total Variation, Adaptive weighted Total Variation and Filtered Backprojection. The novel regularization function uses a priori information about the Gradient Magnitude Distribution of the scanned object for the reconstruction. We provide a general parameterization scheme and evaluate the efficiency of our new algorithm for different noise levels and different number of projection views. When noise is not present, error-free reconstructions are achievable for AwTV and GATV from 40 projections. In cases where noise is simulated, our strategy achieves a Relative Root Mean Square Error that is up to 11 times lower than Total Variation-based and up to 4 times lower than AwTV-based iterative statistical reconstruction (e.g. for a SNR of 223 and 40 projections). To obtain the same reconstruction quality as achieved by Total Variation, the projection number and the pulse length, and the acquisition time and the dose respectively can be reduced by a factor of approximately 3.5, when AwTV is used and a factor of approximately 6.7, when our proposed algorithm is used.

  16. TH-E-17A-06: Anatomical-Adaptive Compressed Sensing (AACS) Reconstruction for Thoracic 4-Dimensional Cone-Beam CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shieh, C; Kipritidis, J; OBrien, R

    2014-06-15

    Purpose: The Feldkamp-Davis-Kress (FDK) algorithm currently used for clinical thoracic 4-dimensional (4D) cone-beam CT (CBCT) reconstruction suffers from noise and streaking artifacts due to projection under-sampling. Compressed sensing theory enables reconstruction of under-sampled datasets via total-variation (TV) minimization, but TV-minimization algorithms such as adaptive-steepest-descent-projection-onto-convex-sets (ASD-POCS) often converge slowly and are prone to over-smoothing anatomical details. These disadvantages can be overcome by incorporating general anatomical knowledge via anatomy segmentation. Based on this concept, we have developed an anatomical-adaptive compressed sensing (AACS) algorithm for thoracic 4D-CBCT reconstruction. Methods: AACS is based on the ASD-POCS framework, where each iteration consists of a TV-minimizationmore » step and a data fidelity constraint step. Prior to every AACS iteration, four major thoracic anatomical structures - soft tissue, lungs, bony anatomy, and pulmonary details - were segmented from the updated solution image. Based on the segmentation, an anatomical-adaptive weighting was applied to the TV-minimization step, so that TV-minimization was enhanced at noisy/streaky regions and suppressed at anatomical structures of interest. The image quality and convergence speed of AACS was compared to conventional ASD-POCS using an XCAT digital phantom and a patient scan. Results: For the XCAT phantom, the AACS image represented the ground truth better than the ASD-POCS image, giving a higher structural similarity index (0.93 vs. 0.84) and lower absolute difference (1.1*10{sup 4} vs. 1.4*10{sup 4}). For the patient case, while both algorithms resulted in much less noise and streaking than FDK, the AACS image showed considerably better contrast and sharpness of the vessels, tumor, and fiducial marker than the ASD-POCS image. In addition, AACS converged over 50% faster than ASD-POCS in both cases. Conclusions: The proposed AACS algorithm was shown to reconstruct thoracic 4D-CBCT images more accurately and with faster convergence compared to ASD-POCS. The superior image quality and rapid convergence makes AACS promising for future clinical use.« less

  17. Novel Fourier-based iterative reconstruction for sparse fan projection using alternating direction total variation minimization

    NASA Astrophysics Data System (ADS)

    Zhao, Jin; Han-Ming, Zhang; Bin, Yan; Lei, Li; Lin-Yuan, Wang; Ai-Long, Cai

    2016-03-01

    Sparse-view x-ray computed tomography (CT) imaging is an interesting topic in CT field and can efficiently decrease radiation dose. Compared with spatial reconstruction, a Fourier-based algorithm has advantages in reconstruction speed and memory usage. A novel Fourier-based iterative reconstruction technique that utilizes non-uniform fast Fourier transform (NUFFT) is presented in this work along with advanced total variation (TV) regularization for a fan sparse-view CT. The proposition of a selective matrix contributes to improve reconstruction quality. The new method employs the NUFFT and its adjoin to iterate back and forth between the Fourier and image space. The performance of the proposed algorithm is demonstrated through a series of digital simulations and experimental phantom studies. Results of the proposed algorithm are compared with those of existing TV-regularized techniques based on compressed sensing method, as well as basic algebraic reconstruction technique. Compared with the existing TV-regularized techniques, the proposed Fourier-based technique significantly improves convergence rate and reduces memory allocation, respectively. Projected supported by the National High Technology Research and Development Program of China (Grant No. 2012AA011603) and the National Natural Science Foundation of China (Grant No. 61372172).

  18. Linear functional minimization for inverse modeling

    DOE PAGES

    Barajas-Solano, David A.; Wohlberg, Brendt Egon; Vesselinov, Velimir Valentinov; ...

    2015-06-01

    In this paper, we present a novel inverse modeling strategy to estimate spatially distributed parameters of nonlinear models. The maximum a posteriori (MAP) estimators of these parameters are based on a likelihood functional, which contains spatially discrete measurements of the system parameters and spatiotemporally discrete measurements of the transient system states. The piecewise continuity prior for the parameters is expressed via Total Variation (TV) regularization. The MAP estimator is computed by minimizing a nonquadratic objective equipped with the TV operator. We apply this inversion algorithm to estimate hydraulic conductivity of a synthetic confined aquifer from measurements of conductivity and hydraulicmore » head. The synthetic conductivity field is composed of a low-conductivity heterogeneous intrusion into a high-conductivity heterogeneous medium. Our algorithm accurately reconstructs the location, orientation, and extent of the intrusion from the steady-state data only. Finally, addition of transient measurements of hydraulic head improves the parameter estimation, accurately reconstructing the conductivity field in the vicinity of observation locations.« less

  19. Digital tomosynthesis (DTS) with a Circular X-ray tube: Its image reconstruction based on total-variation minimization and the image characteristics

    NASA Astrophysics Data System (ADS)

    Park, Y. O.; Hong, D. K.; Cho, H. S.; Je, U. K.; Oh, J. E.; Lee, M. S.; Kim, H. J.; Lee, S. H.; Jang, W. S.; Cho, H. M.; Choi, S. I.; Koo, Y. S.

    2013-09-01

    In this paper, we introduce an effective imaging system for digital tomosynthesis (DTS) with a circular X-ray tube, the so-called circular-DTS (CDTS) system, and its image reconstruction algorithm based on the total-variation (TV) minimization method for low-dose, high-accuracy X-ray imaging. Here, the X-ray tube is equipped with a series of cathodes distributed around a rotating anode, and the detector remains stationary throughout the image acquisition. We considered a TV-based reconstruction algorithm that exploited the sparsity of the image with substantially high image accuracy. We implemented the algorithm for the CDTS geometry and successfully reconstructed images of high accuracy. The image characteristics were investigated quantitatively by using some figures of merit, including the universal-quality index (UQI) and the depth resolution. For selected tomographic angles of 20, 40, and 60°, the corresponding UQI values in the tomographic view were estimated to be about 0.94, 0.97, and 0.98, and the depth resolutions were about 4.6, 3.1, and 1.2 voxels in full width at half maximum (FWHM), respectively. We expect the proposed method to be applicable to developing a next-generation dental or breast X-ray imaging system.

  20. Correction of aeroheating-induced intensity nonuniformity in infrared images

    NASA Astrophysics Data System (ADS)

    Liu, Li; Yan, Luxin; Zhao, Hui; Dai, Xiaobing; Zhang, Tianxu

    2016-05-01

    Aeroheating-induced intensity nonuniformity effects severely influence the effective performance of an infrared (IR) imaging system in high-speed flight. In this paper, we propose a new approach to the correction of intensity nonuniformity in IR images. The basic assumption is that the low-frequency intensity bias is additive and smoothly varying so that it can be modeled as a bivariate polynomial and estimated by using an isotropic total variation (TV) model. A half quadratic penalty method is applied to the isotropic form of TV discretization. And an alternating minimization algorithm is adopted for solving the optimization model. The experimental results of simulated and real aerothermal images show that the proposed correction method can effectively improve IR image quality.

  1. SU-F-18C-14: Hessian-Based Norm Penalty for Weighted Least-Square CBCT Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, T; Sun, N; Tan, S

    Purpose: To develop a Hessian-based norm penalty for cone-beam CT (CBCT) reconstruction that has a similar ability in suppressing noise as the total variation (TV) penalty while avoiding the staircase effect and better preserving low-contrast objects. Methods: We extended the TV penalty to a Hessian-based norm penalty based on the Frobenius norm of the Hessian matrix of an image for CBCT reconstruction. The objective function was constructed using the penalized weighted least-square (PWLS) principle. An effective algorithm was developed to minimize the objective function using a majorization-minimization (MM) approach. We evaluated and compared the proposed penalty with the TV penaltymore » on a CatPhan 600 phantom and an anthropomorphic head phantom, each acquired at a low-dose protocol (10mA/10ms) and a high-dose protocol (80mA/12ms). For both penalties, contrast-to-noise (CNR) in four low-contrast regions-of-interest (ROIs) and the full-width-at-half-maximum (FWHM) of two point-like objects in constructed images were calculated and compared. Results: In the experiment of CatPhan 600 phantom, the Hessian-based norm penalty has slightly higher CNRs and approximately equivalent FWHM values compared with the TV penalty. In the experiment of the anthropomorphic head phantom at the low-dose protocol, the TV penalty result has several artificial piece-wise constant areas known as the staircase effect while in the Hessian-based norm penalty the image appears smoother and more similar to that of the FDK result using the high-dose protocol. Conclusion: The proposed Hessian-based norm penalty has a similar performance in suppressing noise to the TV penalty, but has a potential advantage in suppressing the staircase effect and preserving low-contrast objects. This work was supported in part by National Natural Science Foundation of China (NNSFC), under Grant Nos. 60971112 and 61375018, and Fundamental Research Funds for the Central Universities, under Grant No. 2012QN086.« less

  2. Accurate sparse-projection image reconstruction via nonlocal TV regularization.

    PubMed

    Zhang, Yi; Zhang, Weihua; Zhou, Jiliu

    2014-01-01

    Sparse-projection image reconstruction is a useful approach to lower the radiation dose; however, the incompleteness of projection data will cause degeneration of imaging quality. As a typical compressive sensing method, total variation has obtained great attention on this problem. Suffering from the theoretical imperfection, total variation will produce blocky effect on smooth regions and blur edges. To overcome this problem, in this paper, we introduce the nonlocal total variation into sparse-projection image reconstruction and formulate the minimization problem with new nonlocal total variation norm. The qualitative and quantitative analyses of numerical as well as clinical results demonstrate the validity of the proposed method. Comparing to other existing methods, our method more efficiently suppresses artifacts caused by low-rank reconstruction and reserves structure information better.

  3. Children's Television: An Analysis of Programming and Advertising.

    ERIC Educational Resources Information Center

    Barcus, F. Earle; Wolkin, Rachel

    The studies reported in this book are content analyses of children's television and attendant advertising. Following an introductory statement, chapters present data about children's commercial television on the weekends, children's commercial television after school, and the seasonal variations in television advertising to children. A concluding…

  4. Applications of compressed sensing image reconstruction to sparse view phase tomography

    NASA Astrophysics Data System (ADS)

    Ueda, Ryosuke; Kudo, Hiroyuki; Dong, Jian

    2017-10-01

    X-ray phase CT has a potential to give the higher contrast in soft tissue observations. To shorten the measure- ment time, sparse-view CT data acquisition has been attracting the attention. This paper applies two major compressed sensing (CS) approaches to image reconstruction in the x-ray sparse-view phase tomography. The first CS approach is the standard Total Variation (TV) regularization. The major drawbacks of TV regularization are a patchy artifact and loss in smooth intensity changes due to the piecewise constant nature of image model. The second CS method is a relatively new approach of CS which uses a nonlinear smoothing filter to design the regularization term. The nonlinear filter based CS is expected to reduce the major artifact in the TV regular- ization. The both cost functions can be minimized by the very fast iterative reconstruction method. However, in the past research activities, it is not clearly demonstrated how much image quality difference occurs between the TV regularization and the nonlinear filter based CS in x-ray phase CT applications. We clarify the issue by applying the two CS applications to the case of x-ray phase tomography. We provide results with numerically simulated data, which demonstrates that the nonlinear filter based CS outperforms the TV regularization in terms of textures and smooth intensity changes.

  5. A fast 4D cone beam CT reconstruction method based on the OSC-TV algorithm.

    PubMed

    Mascolo-Fortin, Julia; Matenine, Dmitri; Archambault, Louis; Després, Philippe

    2018-01-01

    Four-dimensional cone beam computed tomography allows for temporally resolved imaging with useful applications in radiotherapy, but raises particular challenges in terms of image quality and computation time. The purpose of this work is to develop a fast and accurate 4D algorithm by adapting a GPU-accelerated ordered subsets convex algorithm (OSC), combined with the total variation minimization regularization technique (TV). Different initialization schemes were studied to adapt the OSC-TV algorithm to 4D reconstruction: each respiratory phase was initialized either with a 3D reconstruction or a blank image. Reconstruction algorithms were tested on a dynamic numerical phantom and on a clinical dataset. 4D iterations were implemented for a cluster of 8 GPUs. All developed methods allowed for an adequate visualization of the respiratory movement and compared favorably to the McKinnon-Bates and adaptive steepest descent projection onto convex sets algorithms, while the 4D reconstructions initialized from a prior 3D reconstruction led to better overall image quality. The most suitable adaptation of OSC-TV to 4D CBCT was found to be a combination of a prior FDK reconstruction and a 4D OSC-TV reconstruction with a reconstruction time of 4.5 minutes. This relatively short reconstruction time could facilitate a clinical use.

  6. Mitigating the Harmful Effects of Violent Television

    ERIC Educational Resources Information Center

    Rosenkoetter, Lawrence I.; Rosenkoetter, Sharon E.; Ozretich, Rachel A.; Acock, Alan C.

    2004-01-01

    In an effort to minimize the harmful effects of violent TV, a yearlong intervention was undertaken with children in Grades 1 through 3 (N = 177). The classroom-based intervention consisted of 31 brief lessons that emphasized the many ways in which television distorts violence. As hypothesized, the intervention resulted in a reduction in children's…

  7. Penalized weighted least-squares approach for multienergy computed tomography image reconstruction via structure tensor total variation regularization.

    PubMed

    Zeng, Dong; Gao, Yuanyuan; Huang, Jing; Bian, Zhaoying; Zhang, Hua; Lu, Lijun; Ma, Jianhua

    2016-10-01

    Multienergy computed tomography (MECT) allows identifying and differentiating different materials through simultaneous capture of multiple sets of energy-selective data belonging to specific energy windows. However, because sufficient photon counts are not available in each energy window compared with that in the whole energy window, the MECT images reconstructed by the analytical approach often suffer from poor signal-to-noise and strong streak artifacts. To address the particular challenge, this work presents a penalized weighted least-squares (PWLS) scheme by incorporating the new concept of structure tensor total variation (STV) regularization, which is henceforth referred to as 'PWLS-STV' for simplicity. Specifically, the STV regularization is derived by penalizing higher-order derivatives of the desired MECT images. Thus it could provide more robust measures of image variation, which can eliminate the patchy artifacts often observed in total variation (TV) regularization. Subsequently, an alternating optimization algorithm was adopted to minimize the objective function. Extensive experiments with a digital XCAT phantom and meat specimen clearly demonstrate that the present PWLS-STV algorithm can achieve more gains than the existing TV-based algorithms and the conventional filtered backpeojection (FBP) algorithm in terms of both quantitative and visual quality evaluations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Piecewise-Constant-Model-Based Interior Tomography Applied to Dentin Tubules

    DOE PAGES

    He, Peng; Wei, Biao; Wang, Steve; ...

    2013-01-01

    Dentin is a hierarchically structured biomineralized composite material, and dentin’s tubules are difficult to study in situ. Nano-CT provides the requisite resolution, but the field of view typically contains only a few tubules. Using a plate-like specimen allows reconstruction of a volume containing specific tubules from a number of truncated projections typically collected over an angular range of about 140°, which is practically accessible. Classical computed tomography (CT) theory cannot exactly reconstruct an object only from truncated projections, needless to say a limited angular range. Recently, interior tomography was developed to reconstruct a region-of-interest (ROI) from truncated data in amore » theoretically exact fashion via the total variation (TV) minimization under the condition that the ROI is piecewise constant. In this paper, we employ a TV minimization interior tomography algorithm to reconstruct interior microstructures in dentin from truncated projections over a limited angular range. Compared to the filtered backprojection (FBP) reconstruction, our reconstruction method reduces noise and suppresses artifacts. Volume rendering confirms the merits of our method in terms of preserving the interior microstructure of the dentin specimen.« less

  9. Cable Television and Public Safety.

    ERIC Educational Resources Information Center

    Cranberg, Gilbert

    One of the most promising applications of cable television (CATV) is municipal surveillance of public areas for protection against crime, fire detection, control of air pollution, and traffic. Thus far, however, the CATV industry has made minimal efforts to realize the potential of CATV for community protection--the use of cable for public safety…

  10. STUDIES IN EDUCATIONAL CLOSED-CIRCUIT TELEVISION.

    ERIC Educational Resources Information Center

    MARTIN, JOHN R.; AND OTHERS

    THE 3 MOST OBJECTED-TO FEATURES OF INSTRUCTIONAL TV ARE (1) RESTRICTIONS IMPOSED BY THE USE OF A SPECIAL STUDIO, (2) LOSS OF TEACHER-STUDENT CONTACT, (3) THE LIMITED VIEWING AREA OF TV SCREENS. THIS STUDY INVESTIGATED 4 CLOSED-CIRCUIT TV COURSES IN AN ATTEMPT TO MINIMIZE FEATURES (1) AND (2). OVER THE ACADEMIC YEAR 1957-58 AT THE CASE INSTITUTE,…

  11. Television Violence: An Intervention to Reduce Its Impact on Children

    ERIC Educational Resources Information Center

    Rosenkoetter, Lawrence I.; Rosenkoetter, Sharon E.; Acock, Alan C.

    2008-01-01

    In an attempt to minimize the adverse effects of television violence, the authors implemented a classroom-based intervention with 496 children in 32 classrooms (grades 1 to 4). The intervention consisted of 28 brief lessons conducted by university staff over the course of 7 months. Participants were individually interviewed prior to the…

  12. TU-CD-BRA-12: Coupling PET Image Restoration and Segmentation Using Variational Method with Multiple Regularizations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, L; Tan, S; Lu, W

    Purpose: To propose a new variational method which couples image restoration with tumor segmentation for PET images using multiple regularizations. Methods: Partial volume effect (PVE) is a major degrading factor impacting tumor segmentation accuracy in PET imaging. The existing segmentation methods usually need to take prior calibrations to compensate PVE and they are highly system-dependent. Taking into account that image restoration and segmentation can promote each other and they are tightly coupled, we proposed a variational method to solve the two problems together. Our method integrated total variation (TV) semi-blind deconvolution and Mumford-Shah (MS) segmentation. The TV norm was usedmore » on edges to protect the edge information, and the L{sub 2} norm was used to avoid staircase effect in the no-edge area. The blur kernel was constrained to the Gaussian model parameterized by its variance and we assumed that the variances in the X-Y and Z directions are different. The energy functional was iteratively optimized by an alternate minimization algorithm. Segmentation performance was tested on eleven patients with non-Hodgkin’s lymphoma, and evaluated by Dice similarity index (DSI) and classification error (CE). For comparison, seven other widely used methods were also tested and evaluated. Results: The combination of TV and L{sub 2} regularizations effectively improved the segmentation accuracy. The average DSI increased by around 0.1 than using either the TV or the L{sub 2} norm. The proposed method was obviously superior to other tested methods. It has an average DSI and CE of 0.80 and 0.41, while the FCM method — the second best one — has only an average DSI and CE of 0.66 and 0.64. Conclusion: Coupling image restoration and segmentation can handle PVE and thus improves tumor segmentation accuracy in PET. Alternate use of TV and L2 regularizations can further improve the performance of the algorithm. This work was supported in part by National Natural Science Foundation of China (NNSFC), under Grant No.61375018, and Fundamental Research Funds for the Central Universities, under Grant No. 2012QN086. Wei Lu was supported in part by the National Institutes of Health (NIH) Grant No. R01 CA172638.« less

  13. Low-dose X-ray CT reconstruction via dictionary learning.

    PubMed

    Xu, Qiong; Yu, Hengyong; Mou, Xuanqin; Zhang, Lei; Hsieh, Jiang; Wang, Ge

    2012-09-01

    Although diagnostic medical imaging provides enormous benefits in the early detection and accuracy diagnosis of various diseases, there are growing concerns on the potential side effect of radiation induced genetic, cancerous and other diseases. How to reduce radiation dose while maintaining the diagnostic performance is a major challenge in the computed tomography (CT) field. Inspired by the compressive sensing theory, the sparse constraint in terms of total variation (TV) minimization has already led to promising results for low-dose CT reconstruction. Compared to the discrete gradient transform used in the TV method, dictionary learning is proven to be an effective way for sparse representation. On the other hand, it is important to consider the statistical property of projection data in the low-dose CT case. Recently, we have developed a dictionary learning based approach for low-dose X-ray CT. In this paper, we present this method in detail and evaluate it in experiments. In our method, the sparse constraint in terms of a redundant dictionary is incorporated into an objective function in a statistical iterative reconstruction framework. The dictionary can be either predetermined before an image reconstruction task or adaptively defined during the reconstruction process. An alternating minimization scheme is developed to minimize the objective function. Our approach is evaluated with low-dose X-ray projections collected in animal and human CT studies, and the improvement associated with dictionary learning is quantified relative to filtered backprojection and TV-based reconstructions. The results show that the proposed approach might produce better images with lower noise and more detailed structural features in our selected cases. However, there is no proof that this is true for all kinds of structures.

  14. Low-Dose X-ray CT Reconstruction via Dictionary Learning

    PubMed Central

    Xu, Qiong; Zhang, Lei; Hsieh, Jiang; Wang, Ge

    2013-01-01

    Although diagnostic medical imaging provides enormous benefits in the early detection and accuracy diagnosis of various diseases, there are growing concerns on the potential side effect of radiation induced genetic, cancerous and other diseases. How to reduce radiation dose while maintaining the diagnostic performance is a major challenge in the computed tomography (CT) field. Inspired by the compressive sensing theory, the sparse constraint in terms of total variation (TV) minimization has already led to promising results for low-dose CT reconstruction. Compared to the discrete gradient transform used in the TV method, dictionary learning is proven to be an effective way for sparse representation. On the other hand, it is important to consider the statistical property of projection data in the low-dose CT case. Recently, we have developed a dictionary learning based approach for low-dose X-ray CT. In this paper, we present this method in detail and evaluate it in experiments. In our method, the sparse constraint in terms of a redundant dictionary is incorporated into an objective function in a statistical iterative reconstruction framework. The dictionary can be either predetermined before an image reconstruction task or adaptively defined during the reconstruction process. An alternating minimization scheme is developed to minimize the objective function. Our approach is evaluated with low-dose X-ray projections collected in animal and human CT studies, and the improvement associated with dictionary learning is quantified relative to filtered backprojection and TV-based reconstructions. The results show that the proposed approach might produce better images with lower noise and more detailed structural features in our selected cases. However, there is no proof that this is true for all kinds of structures. PMID:22542666

  15. Dialectical Features of Black Characters in Situation Comedies on Television.

    ERIC Educational Resources Information Center

    Fine, Marlene G.; Anderson, Carolyn

    1980-01-01

    Three prime time television situation comedies with primarily Black casts were studied for frequency and variations in use of Black English Vernacular (BEV). It is suggested that homogenization of BEV on American television reflects the attitude that BEV is not a legitimate language choice. (GC)

  16. Desert Survivors: The Design and Implementation of a Television Program to Enhance Local Scientific Literacy

    ERIC Educational Resources Information Center

    Utz, Jenifer C.; Rausch, Candice M.; Fruth, Laurie; Thomas, Megan E.; van Breukelen, Frank

    2007-01-01

    Outreach efforts by faculty members are oftentimes limited in scope due to hectic schedules. We developed a program to enhance science literacy in elementary school children that allows experts to reach a tremendous audience while minimizing their time commitment. The foundation of the program is a television series entitled "Desert Survivors."…

  17. An iterative algorithm for L1-TV constrained regularization in image restoration

    NASA Astrophysics Data System (ADS)

    Chen, K.; Loli Piccolomini, E.; Zama, F.

    2015-11-01

    We consider the problem of restoring blurred images affected by impulsive noise. The adopted method restores the images by solving a sequence of constrained minimization problems where the data fidelity function is the ℓ1 norm of the residual and the constraint, chosen as the image Total Variation, is automatically adapted to improve the quality of the restored images. Although this approach is general, we report here the case of vectorial images where the blurring model involves contributions from the different image channels (cross channel blur). A computationally convenient extension of the Total Variation function to vectorial images is used and the results reported show that this approach is efficient for recovering nearly optimal images.

  18. Simultaneous Tumor Segmentation, Image Restoration, and Blur Kernel Estimation in PET Using Multiple Regularizations

    PubMed Central

    Li, Laquan; Wang, Jian; Lu, Wei; Tan, Shan

    2016-01-01

    Accurate tumor segmentation from PET images is crucial in many radiation oncology applications. Among others, partial volume effect (PVE) is recognized as one of the most important factors degrading imaging quality and segmentation accuracy in PET. Taking into account that image restoration and tumor segmentation are tightly coupled and can promote each other, we proposed a variational method to solve both problems simultaneously in this study. The proposed method integrated total variation (TV) semi-blind de-convolution and Mumford-Shah segmentation with multiple regularizations. Unlike many existing energy minimization methods using either TV or L2 regularization, the proposed method employed TV regularization over tumor edges to preserve edge information, and L2 regularization inside tumor regions to preserve the smooth change of the metabolic uptake in a PET image. The blur kernel was modeled as anisotropic Gaussian to address the resolution difference in transverse and axial directions commonly seen in a clinic PET scanner. The energy functional was rephrased using the Γ-convergence approximation and was iteratively optimized using the alternating minimization (AM) algorithm. The performance of the proposed method was validated on a physical phantom and two clinic datasets with non-Hodgkin’s lymphoma and esophageal cancer, respectively. Experimental results demonstrated that the proposed method had high performance for simultaneous image restoration, tumor segmentation and scanner blur kernel estimation. Particularly, the recovery coefficients (RC) of the restored images of the proposed method in the phantom study were close to 1, indicating an efficient recovery of the original blurred images; for segmentation the proposed method achieved average dice similarity indexes (DSIs) of 0.79 and 0.80 for two clinic datasets, respectively; and the relative errors of the estimated blur kernel widths were less than 19% in the transversal direction and 7% in the axial direction. PMID:28603407

  19. Improved ultrasonic TV images achieved by use of Lamb-wave orientation technique

    NASA Technical Reports Server (NTRS)

    Berger, H.

    1967-01-01

    Lamb-wave sample orientation technique minimizes the interference from standing waves in continuous wave ultrasonic television imaging techniques used with thin metallic samples. The sample under investigation is oriented such that the wave incident upon it is not normal, but slightly angled.

  20. Color TV: total variation methods for restoration of vector-valued images.

    PubMed

    Blomgren, P; Chan, T F

    1998-01-01

    We propose a new definition of the total variation (TV) norm for vector-valued functions that can be applied to restore color and other vector-valued images. The new TV norm has the desirable properties of 1) not penalizing discontinuities (edges) in the image, 2) being rotationally invariant in the image space, and 3) reducing to the usual TV norm in the scalar case. Some numerical experiments on denoising simple color images in red-green-blue (RGB) color space are presented.

  1. Generalized Scalar-on-Image Regression Models via Total Variation.

    PubMed

    Wang, Xiao; Zhu, Hongtu

    2017-01-01

    The use of imaging markers to predict clinical outcomes can have a great impact in public health. The aim of this paper is to develop a class of generalized scalar-on-image regression models via total variation (GSIRM-TV), in the sense of generalized linear models, for scalar response and imaging predictor with the presence of scalar covariates. A key novelty of GSIRM-TV is that it is assumed that the slope function (or image) of GSIRM-TV belongs to the space of bounded total variation in order to explicitly account for the piecewise smooth nature of most imaging data. We develop an efficient penalized total variation optimization to estimate the unknown slope function and other parameters. We also establish nonasymptotic error bounds on the excess risk. These bounds are explicitly specified in terms of sample size, image size, and image smoothness. Our simulations demonstrate a superior performance of GSIRM-TV against many existing approaches. We apply GSIRM-TV to the analysis of hippocampus data obtained from the Alzheimers Disease Neuroimaging Initiative (ADNI) dataset.

  2. 75 FR 35027 - Notice of Public Information Collection Being Reviewed by the Federal Communications Commission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-21

    ... enhance the quality, utility, and clarity of the information collected; (d) ways to minimize the burden of... collection of information. Needs and Uses: 47 CFR 73.1125(d)(1) requires AM, FM or TV licensees to notify the..., or the Video Division for TV and Class A television stations before the studio may be moved to that...

  3. Economical Video Monitoring of Traffic

    NASA Technical Reports Server (NTRS)

    Houser, B. C.; Paine, G.; Rubenstein, L. D.; Parham, O. Bruce, Jr.; Graves, W.; Bradley, C.

    1986-01-01

    Data compression allows video signals to be transmitted economically on telephone circuits. Telephone lines transmit television signals to remote traffic-control center. Lines also carry command signals from center to TV camera and compressor at highway site. Video system with television cameras positioned at critical points on highways allows traffic controllers to determine visually, almost immediately, exact cause of traffic-flow disruption; e.g., accidents, breakdowns, or spills, almost immediately. Controllers can then dispatch appropriate emergency services and alert motorists to minimize traffic backups.

  4. ATS-6 - Television Relay Using Small Terminals Experiment

    NASA Technical Reports Server (NTRS)

    Miller, J. E.

    1975-01-01

    The Television Relay Using Small Terminals (TRUST) Experiment was designed to advance and promote the technology of broadcasting satellites. A constant envelope television FM signal was transmitted at C band to the ATS-6 earth coverage horn and retransmitted at 860 MHz through the 9-m antenna to a low-cost direct-readout ground station. The experiment demonstrated that high-quality television and audio can be received by low-cost direct-receive ground stations. Predetection bandwidths significantly less than predicted by Carson's rule can be utilized with minimal degradation of either monochrome or color pictures. Two separate techniques of dual audio channel transmission have been demonstrated to be suitable for low-cost applications.

  5. Evaluation of hybrid SART  +  OS  +  TV iterative reconstruction algorithm for optical-CT gel dosimeter imaging

    NASA Astrophysics Data System (ADS)

    Du, Yi; Wang, Xiangang; Xiang, Xincheng; Wei, Zhouping

    2016-12-01

    Optical computed tomography (optical-CT) is a high-resolution, fast, and easily accessible readout modality for gel dosimeters. This paper evaluates a hybrid iterative image reconstruction algorithm for optical-CT gel dosimeter imaging, namely, the simultaneous algebraic reconstruction technique (SART) integrated with ordered subsets (OS) iteration and total variation (TV) minimization regularization. The mathematical theory and implementation workflow of the algorithm are detailed. Experiments on two different optical-CT scanners were performed for cross-platform validation. For algorithm evaluation, the iterative convergence is first shown, and peak-to-noise-ratio (PNR) and contrast-to-noise ratio (CNR) results are given with the cone-beam filtered backprojection (FDK) algorithm and the FDK results followed by median filtering (mFDK) as reference. The effect on spatial gradients and reconstruction artefacts is also investigated. The PNR curve illustrates that the results of SART  +  OS  +  TV finally converges to that of FDK but with less noise, which implies that the dose-OD calibration method for FDK is also applicable to the proposed algorithm. The CNR in selected regions-of-interest (ROIs) of SART  +  OS  +  TV results is almost double that of FDK and 50% higher than that of mFDK. The artefacts in SART  +  OS  +  TV results are still visible, but have been much suppressed with little spatial gradient loss. Based on the assessment, we can conclude that this hybrid SART  +  OS  +  TV algorithm outperforms both FDK and mFDK in denoising, preserving spatial dose gradients and reducing artefacts, and its effectiveness and efficiency are platform independent.

  6. Fast alternating projection methods for constrained tomographic reconstruction

    PubMed Central

    Liu, Li; Han, Yongxin

    2017-01-01

    The alternating projection algorithms are easy to implement and effective for large-scale complex optimization problems, such as constrained reconstruction of X-ray computed tomography (CT). A typical method is to use projection onto convex sets (POCS) for data fidelity, nonnegative constraints combined with total variation (TV) minimization (so called TV-POCS) for sparse-view CT reconstruction. However, this type of method relies on empirically selected parameters for satisfactory reconstruction and is generally slow and lack of convergence analysis. In this work, we use a convex feasibility set approach to address the problems associated with TV-POCS and propose a framework using full sequential alternating projections or POCS (FS-POCS) to find the solution in the intersection of convex constraints of bounded TV function, bounded data fidelity error and non-negativity. The rationale behind FS-POCS is that the mathematically optimal solution of the constrained objective function may not be the physically optimal solution. The breakdown of constrained reconstruction into an intersection of several feasible sets can lead to faster convergence and better quantification of reconstruction parameters in a physical meaningful way than that in an empirical way of trial-and-error. In addition, for large-scale optimization problems, first order methods are usually used. Not only is the condition for convergence of gradient-based methods derived, but also a primal-dual hybrid gradient (PDHG) method is used for fast convergence of bounded TV. The newly proposed FS-POCS is evaluated and compared with TV-POCS and another convex feasibility projection method (CPTV) using both digital phantom and pseudo-real CT data to show its superior performance on reconstruction speed, image quality and quantification. PMID:28253298

  7. 75 FR 52746 - Notice of Public Information Collection(s) Being Reviewed by the Federal Communications...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ... enhance the quality, utility, and clarity of the information collected; (d) ways to minimize the burden of... TV broadcast and Digital TV (DTV) operations. The Commission permits broadcasters to agree to... broadcast facilities will not result in additional interference to existing TV and DTV broadcast facilities...

  8. Blind motion image deblurring using nonconvex higher-order total variation model

    NASA Astrophysics Data System (ADS)

    Li, Weihong; Chen, Rui; Xu, Shangwen; Gong, Weiguo

    2016-09-01

    We propose a nonconvex higher-order total variation (TV) method for blind motion image deblurring. First, we introduce a nonconvex higher-order TV differential operator to define a new model of the blind motion image deblurring, which can effectively eliminate the staircase effect of the deblurred image; meanwhile, we employ an image sparse prior to improve the edge recovery quality. Second, to improve the accuracy of the estimated motion blur kernel, we use L1 norm and H1 norm as the blur kernel regularization term, considering the sparsity and smoothing of the motion blur kernel. Third, because it is difficult to solve the numerically computational complexity problem of the proposed model owing to the intrinsic nonconvexity, we propose a binary iterative strategy, which incorporates a reweighted minimization approximating scheme in the outer iteration, and a split Bregman algorithm in the inner iteration. And we also discuss the convergence of the proposed binary iterative strategy. Last, we conduct extensive experiments on both synthetic and real-world degraded images. The results demonstrate that the proposed method outperforms the previous representative methods in both quality of visual perception and quantitative measurement.

  9. Moving object detection via low-rank total variation regularization

    NASA Astrophysics Data System (ADS)

    Wang, Pengcheng; Chen, Qian; Shao, Na

    2016-09-01

    Moving object detection is a challenging task in video surveillance. Recently proposed Robust Principal Component Analysis (RPCA) can recover the outlier patterns from the low-rank data under some mild conditions. However, the l-penalty in RPCA doesn't work well in moving object detection because the irrepresentable condition is often not satisfied. In this paper, a method based on total variation (TV) regularization scheme is proposed. In our model, image sequences captured with a static camera are highly related, which can be described using a low-rank matrix. Meanwhile, the low-rank matrix can absorb background motion, e.g. periodic and random perturbation. The foreground objects in the sequence are usually sparsely distributed and drifting continuously, and can be treated as group outliers from the highly-related background scenes. Instead of l-penalty, we exploit the total variation of the foreground. By minimizing the total variation energy, the outliers tend to collapse and finally converge to be the exact moving objects. The TV-penalty is superior to the l-penalty especially when the outlier is in the majority for some pixels, and our method can estimate the outlier explicitly with less bias but higher variance. To solve the problem, a joint optimization function is formulated and can be effectively solved through the inexact Augmented Lagrange Multiplier (ALM) method. We evaluate our method along with several state-of-the-art approaches in MATLAB. Both qualitative and quantitative results demonstrate that our proposed method works effectively on a large range of complex scenarios.

  10. Television Viewing by Young Secondary Students: A Study of the Television Viewing Behavior of Children at Form Two Level.

    ERIC Educational Resources Information Center

    Powell, R. J.

    Television viewing habits of 12 to 14 year olds in Australia were studied, and an attempt was made to correlate amount of viewing time and choice of programs with these children's intelligence and personality. Average viewing time per night was three hours and 40 minutes. A large variation was found in the time at which children ceased viewing.…

  11. 75 FR 21626 - Notice of Public Information Collection Being Reviewed by the Federal Communications Commission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-26

    ... enhance the quality, utility, and clarity of the information collected; (d) ways to minimize the burden of..., TV Broadcast Receivers. Form Number: N/A. Type of Review: Extension of a currently approved... Commission's rules requires sellers of TV sets (and other TV receiver equipment) that do not contain a...

  12. GPU-accelerated regularized iterative reconstruction for few-view cone beam CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matenine, Dmitri, E-mail: dmitri.matenine.1@ulaval.ca; Goussard, Yves, E-mail: yves.goussard@polymtl.ca; Després, Philippe, E-mail: philippe.despres@phy.ulaval.ca

    2015-04-15

    Purpose: The present work proposes an iterative reconstruction technique designed for x-ray transmission computed tomography (CT). The main objective is to provide a model-based solution to the cone-beam CT reconstruction problem, yielding accurate low-dose images via few-views acquisitions in clinically acceptable time frames. Methods: The proposed technique combines a modified ordered subsets convex (OSC) algorithm and the total variation minimization (TV) regularization technique and is called OSC-TV. The number of subsets of each OSC iteration follows a reduction pattern in order to ensure the best performance of the regularization method. Considering the high computational cost of the algorithm, it ismore » implemented on a graphics processing unit, using parallelization to accelerate computations. Results: The reconstructions were performed on computer-simulated as well as human pelvic cone-beam CT projection data and image quality was assessed. In terms of convergence and image quality, OSC-TV performs well in reconstruction of low-dose cone-beam CT data obtained via a few-view acquisition protocol. It compares favorably to the few-view TV-regularized projections onto convex sets (POCS-TV) algorithm. It also appears to be a viable alternative to full-dataset filtered backprojection. Execution times are of 1–2 min and are compatible with the typical clinical workflow for nonreal-time applications. Conclusions: Considering the image quality and execution times, this method may be useful for reconstruction of low-dose clinical acquisitions. It may be of particular benefit to patients who undergo multiple acquisitions by reducing the overall imaging radiation dose and associated risks.« less

  13. Symbolic Capital in a Virtual Heterosexual Market: Abbreviation and Insertion in Italian iTV SMS

    ERIC Educational Resources Information Center

    Herring, Susan C.; Zelenkauskaite, Asta

    2009-01-01

    This study analyzes gender variation in nonstandard typography--specifically, abbreviations and insertions--in mobile phone text messages (SMS) posted to a public Italian interactive television (iTV) program. All broadcast SMS were collected for a period of 2 days from the Web archive for the iTV program, and the frequency and distribution of…

  14. The Gratifications of Grazing: Why Flippers Flip.

    ERIC Educational Resources Information Center

    Walker, James R.; Bellamy, Robert V., Jr.

    An exploratory study focused on usage patterns of television remote control devices (RCDs), examining how and why individuals use television RCDs to "graze." The study identified the gratifications obtained from RCD use and evaluated their relative importance in accounting for variations in RCD use. Subjects were 455 undergraduates in…

  15. Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matenine, Dmitri, E-mail: dmitri.matenine.1@ulaval.ca; Mascolo-Fortin, Julia, E-mail: julia.mascolo-fortin.1@ulaval.ca; Goussard, Yves, E-mail: yves.goussard@polymtl.ca

    Purpose: The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. Methods: This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numericalmore » simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. Results: The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. Conclusions: The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of spatial features and reduce cone-beam optical CT artifacts.« less

  16. Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT.

    PubMed

    Matenine, Dmitri; Mascolo-Fortin, Julia; Goussard, Yves; Després, Philippe

    2015-11-01

    The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of spatial features and reduce cone-beam optical CT artifacts.

  17. Iterative image reconstruction that includes a total variation regularization for radial MRI.

    PubMed

    Kojima, Shinya; Shinohara, Hiroyuki; Hashimoto, Takeyuki; Hirata, Masami; Ueno, Eiko

    2015-07-01

    This paper presents an iterative image reconstruction method for radial encodings in MRI based on a total variation (TV) regularization. The algebraic reconstruction method combined with total variation regularization (ART_TV) is implemented with a regularization parameter specifying the weight of the TV term in the optimization process. We used numerical simulations of a Shepp-Logan phantom, as well as experimental imaging of a phantom that included a rectangular-wave chart, to evaluate the performance of ART_TV, and to compare it with that of the Fourier transform (FT) method. The trade-off between spatial resolution and signal-to-noise ratio (SNR) was investigated for different values of the regularization parameter by experiments on a phantom and a commercially available MRI system. ART_TV was inferior to the FT with respect to the evaluation of the modulation transfer function (MTF), especially at high frequencies; however, it outperformed the FT with regard to the SNR. In accordance with the results of SNR measurement, visual impression suggested that the image quality of ART_TV was better than that of the FT for reconstruction of a noisy image of a kiwi fruit. In conclusion, ART_TV provides radial MRI with improved image quality for low-SNR data; however, the regularization parameter in ART_TV is a critical factor for obtaining improvement over the FT.

  18. Higher order total variation regularization for EIT reconstruction.

    PubMed

    Gong, Bo; Schullcke, Benjamin; Krueger-Ziolek, Sabine; Zhang, Fan; Mueller-Lisse, Ullrich; Moeller, Knut

    2018-01-08

    Electrical impedance tomography (EIT) attempts to reveal the conductivity distribution of a domain based on the electrical boundary condition. This is an ill-posed inverse problem; its solution is very unstable. Total variation (TV) regularization is one of the techniques commonly employed to stabilize reconstructions. However, it is well known that TV regularization induces staircase effects, which are not realistic in clinical applications. To reduce such artifacts, modified TV regularization terms considering a higher order differential operator were developed in several previous studies. One of them is called total generalized variation (TGV) regularization. TGV regularization has been successively applied in image processing in a regular grid context. In this study, we adapted TGV regularization to the finite element model (FEM) framework for EIT reconstruction. Reconstructions using simulation and clinical data were performed. First results indicate that, in comparison to TV regularization, TGV regularization promotes more realistic images. Graphical abstract Reconstructed conductivity changes located on selected vertical lines. For each of the reconstructed images as well as the ground truth image, conductivity changes located along the selected left and right vertical lines are plotted. In these plots, the notation GT in the legend stands for ground truth, TV stands for total variation method, and TGV stands for total generalized variation method. Reconstructed conductivity distributions from the GREIT algorithm are also demonstrated.

  19. 76 FR 28031 - Information Collection Being Reviewed by the Federal Communications Commission Under Delegated...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-13

    ... the quality, utility, and clarity of the information collected; (d) ways to minimize the burden of the... kilometers of a TV channel 7 transmitter to ensure that the system does not cause interference to TV channel 7 viewers. Applicants shall serve a copy of the analysis to the licensee of the affected TV Channel...

  20. High speed television camera system processes photographic film data for digital computer analysis

    NASA Technical Reports Server (NTRS)

    Habbal, N. A.

    1970-01-01

    Data acquisition system translates and processes graphical information recorded on high speed photographic film. It automatically scans the film and stores the information with a minimal use of the computer memory.

  1. A promising limited angular computed tomography reconstruction via segmentation based regional enhancement and total variation minimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Wenkun; Zhang, Hanming; Li, Lei

    2016-08-15

    X-ray computed tomography (CT) is a powerful and common inspection technique used for the industrial non-destructive testing. However, large-sized and heavily absorbing objects cause the formation of artifacts because of either the lack of specimen penetration in specific directions or the acquisition of data from only a limited angular range of views. Although the sparse optimization-based methods, such as the total variation (TV) minimization method, can suppress artifacts to some extent, reconstructing the images such that they converge to accurate values remains difficult because of the deficiency in continuous angular data and inconsistency in the projections. To address this problem,more » we use the idea of regional enhancement of the true values and suppression of the illusory artifacts outside the region to develop an efficient iterative algorithm. This algorithm is based on the combination of regional enhancement of the true values and TV minimization for the limited angular reconstruction. In this algorithm, the segmentation approach is introduced to distinguish the regions of different image knowledge and generate the support mask of the image. A new regularization term, which contains the support knowledge to enhance the true values of the image, is incorporated into the objective function. Then, the proposed optimization model is solved by variable splitting and the alternating direction method efficiently. A compensation approach is also designed to extract useful information from the initial projections and thus reduce false segmentation result and correct the segmentation support and the segmented image. The results obtained from comparing both simulation studies and real CT data set reconstructions indicate that the proposed algorithm generates a more accurate image than do the other reconstruction methods. The experimental results show that this algorithm can produce high-quality reconstructed images for the limited angular reconstruction and suppress the illusory artifacts caused by the deficiency in valid data.« less

  2. A promising limited angular computed tomography reconstruction via segmentation based regional enhancement and total variation minimization

    NASA Astrophysics Data System (ADS)

    Zhang, Wenkun; Zhang, Hanming; Li, Lei; Wang, Linyuan; Cai, Ailong; Li, Zhongguo; Yan, Bin

    2016-08-01

    X-ray computed tomography (CT) is a powerful and common inspection technique used for the industrial non-destructive testing. However, large-sized and heavily absorbing objects cause the formation of artifacts because of either the lack of specimen penetration in specific directions or the acquisition of data from only a limited angular range of views. Although the sparse optimization-based methods, such as the total variation (TV) minimization method, can suppress artifacts to some extent, reconstructing the images such that they converge to accurate values remains difficult because of the deficiency in continuous angular data and inconsistency in the projections. To address this problem, we use the idea of regional enhancement of the true values and suppression of the illusory artifacts outside the region to develop an efficient iterative algorithm. This algorithm is based on the combination of regional enhancement of the true values and TV minimization for the limited angular reconstruction. In this algorithm, the segmentation approach is introduced to distinguish the regions of different image knowledge and generate the support mask of the image. A new regularization term, which contains the support knowledge to enhance the true values of the image, is incorporated into the objective function. Then, the proposed optimization model is solved by variable splitting and the alternating direction method efficiently. A compensation approach is also designed to extract useful information from the initial projections and thus reduce false segmentation result and correct the segmentation support and the segmented image. The results obtained from comparing both simulation studies and real CT data set reconstructions indicate that the proposed algorithm generates a more accurate image than do the other reconstruction methods. The experimental results show that this algorithm can produce high-quality reconstructed images for the limited angular reconstruction and suppress the illusory artifacts caused by the deficiency in valid data.

  3. Building Security into Schools.

    ERIC Educational Resources Information Center

    Kosar, John E.; Ahmed, Faruq

    2000-01-01

    Offers tips for redesigning safer school sites; installing and implementing security technologies (closed-circuit television cameras, door security hardware, electronic security panels, identification cards, metal detectors, and panic buttons); educating students and staff about security functions; and minimizing costs via a comprehensive campus…

  4. Artifact reduction in short-scan CBCT by use of optimization-based reconstruction

    PubMed Central

    Zhang, Zheng; Han, Xiao; Pearson, Erik; Pelizzari, Charles; Sidky, Emil Y; Pan, Xiaochuan

    2017-01-01

    Increasing interest in optimization-based reconstruction in research on, and applications of, cone-beam computed tomography (CBCT) exists because it has been shown to have to potential to reduce artifacts observed in reconstructions obtained with the Feldkamp–Davis–Kress (FDK) algorithm (or its variants), which is used extensively for image reconstruction in current CBCT applications. In this work, we carried out a study on optimization-based reconstruction for possible reduction of artifacts in FDK reconstruction specifically from short-scan CBCT data. The investigation includes a set of optimization programs such as the image-total-variation (TV)-constrained data-divergency minimization, data-weighting matrices such as the Parker weighting matrix, and objects of practical interest for demonstrating and assessing the degree of artifact reduction. Results of investigative work reveal that appropriately designed optimization-based reconstruction, including the image-TV-constrained reconstruction, can reduce significant artifacts observed in FDK reconstruction in CBCT with a short-scan configuration. PMID:27046218

  5. Investigation of cone-beam CT image quality trade-off for image-guided radiation therapy

    NASA Astrophysics Data System (ADS)

    Bian, Junguo; Sharp, Gregory C.; Park, Yang-Kyun; Ouyang, Jinsong; Bortfeld, Thomas; El Fakhri, Georges

    2016-05-01

    It is well-known that projections acquired over an angular range slightly over 180° (so-called short scan) are sufficient for fan-beam reconstruction. However, due to practical imaging conditions (projection data and reconstruction image discretization, physical factors, and data noise), the short-scan reconstructions may have different appearances and properties from the full-scan (scans over 360°) reconstructions. Nevertheless, short-scan configurations have been used in applications such as cone-beam CT (CBCT) for head-neck-cancer image-guided radiation therapy (IGRT) that only requires a small field of view due to the potential reduced imaging time and dose. In this work, we studied the image quality trade-off for full, short, and full/short scan configurations with both conventional filtered-backprojection (FBP) reconstruction and iterative reconstruction algorithms based on total-variation (TV) minimization for head-neck-cancer IGRT. Anthropomorphic and Catphan phantoms were scanned at different exposure levels with a clinical scanner used in IGRT. Both visualization- and numerical-metric-based evaluation studies were performed. The results indicate that the optimal exposure level and number of views are in the middle range for both FBP and TV-based iterative algorithms and the optimization is object-dependent and task-dependent. The optimal view numbers decrease with the total exposure levels for both FBP and TV-based algorithms. The results also indicate there are slight differences between FBP and TV-based iterative algorithms for the image quality trade-off: FBP seems to be more in favor of larger number of views while the TV-based algorithm is more robust to different data conditions (number of views and exposure levels) than the FBP algorithm. The studies can provide a general guideline for image-quality optimization for CBCT used in IGRT and other applications.

  6. Investigation of cone-beam CT image quality trade-off for image-guided radiation therapy.

    PubMed

    Bian, Junguo; Sharp, Gregory C; Park, Yang-Kyun; Ouyang, Jinsong; Bortfeld, Thomas; El Fakhri, Georges

    2016-05-07

    It is well-known that projections acquired over an angular range slightly over 180° (so-called short scan) are sufficient for fan-beam reconstruction. However, due to practical imaging conditions (projection data and reconstruction image discretization, physical factors, and data noise), the short-scan reconstructions may have different appearances and properties from the full-scan (scans over 360°) reconstructions. Nevertheless, short-scan configurations have been used in applications such as cone-beam CT (CBCT) for head-neck-cancer image-guided radiation therapy (IGRT) that only requires a small field of view due to the potential reduced imaging time and dose. In this work, we studied the image quality trade-off for full, short, and full/short scan configurations with both conventional filtered-backprojection (FBP) reconstruction and iterative reconstruction algorithms based on total-variation (TV) minimization for head-neck-cancer IGRT. Anthropomorphic and Catphan phantoms were scanned at different exposure levels with a clinical scanner used in IGRT. Both visualization- and numerical-metric-based evaluation studies were performed. The results indicate that the optimal exposure level and number of views are in the middle range for both FBP and TV-based iterative algorithms and the optimization is object-dependent and task-dependent. The optimal view numbers decrease with the total exposure levels for both FBP and TV-based algorithms. The results also indicate there are slight differences between FBP and TV-based iterative algorithms for the image quality trade-off: FBP seems to be more in favor of larger number of views while the TV-based algorithm is more robust to different data conditions (number of views and exposure levels) than the FBP algorithm. The studies can provide a general guideline for image-quality optimization for CBCT used in IGRT and other applications.

  7. SPECT reconstruction with nonuniform attenuation from highly under-sampled projection data

    NASA Astrophysics Data System (ADS)

    Li, Cuifen; Wen, Junhai; Zhang, Kangping; Shi, Donghao; Dong, Haixiang; Li, Wenxiao; Liang, Zhengrong

    2012-03-01

    Single photon emission computed tomography (SPECT) is an important nuclear medicine imaging technique and has been using in clinical diagnoses. The SPECT image can reflect not only organizational structure but also functional activities of human body, therefore diseases can be found much earlier. In SPECT, the reconstruction is based on the measurement of gamma photons emitted by the radiotracer. The number of gamma photons detected is proportional to the dose of radiopharmaceutical, but the dose is limited because of patient safety. There is an upper limit in the number of gamma photons that can be detected per unit time, so it takes a long time to acquire SPECT projection data. Sometimes we just can obtain highly under-sampled projection data because of the limit of the scanning time or imaging hardware. How to reconstruct an image using highly under-sampled projection data is an interesting problem. One method is to minimize the total variation (TV) of the reconstructed image during the iterative reconstruction. In this work, we developed an OSEM-TV SPECT reconstruction algorithm, which could reconstruct the image from highly under-sampled projection data with non-uniform attenuation. Simulation results demonstrate that the OSEM-TV algorithm performs well in SPECT reconstruction with non-uniform attenuation.

  8. A generalized Condat's algorithm of 1D total variation regularization

    NASA Astrophysics Data System (ADS)

    Makovetskii, Artyom; Voronin, Sergei; Kober, Vitaly

    2017-09-01

    A common way for solving the denosing problem is to utilize the total variation (TV) regularization. Many efficient numerical algorithms have been developed for solving the TV regularization problem. Condat described a fast direct algorithm to compute the processed 1D signal. Also there exists a direct algorithm with a linear time for 1D TV denoising referred to as the taut string algorithm. The Condat's algorithm is based on a dual problem to the 1D TV regularization. In this paper, we propose a variant of the Condat's algorithm based on the direct 1D TV regularization problem. The usage of the Condat's algorithm with the taut string approach leads to a clear geometric description of the extremal function. Computer simulation results are provided to illustrate the performance of the proposed algorithm for restoration of degraded signals.

  9. Trends in exposure to televised prescription drug advertising, 2003-2011.

    PubMed

    Kornfield, Rachel; Alexander, G Caleb; Qato, Dima M; Kim, Yoonsang; Hirsch, Jan D; Emery, Sherry L

    2015-05-01

    TV accounts for more than half of pharmaceutical direct-to-consumer advertising (DTCA) spending in the U.S. The purpose of this study is to quantify average household exposure to branded and non-branded (help-seeking) televised prescription drug advertisements and describe variation over time and according to medication indication and geography. In 2013, Nielsen TV ratings were compiled for prescription pharmaceutical advertising that aired between 2003 and 2011 for the top 75 U.S. media markets. All advertisements were coded as branded or help-seeking. Advertisements were further coded for one of eight prevalent indications (allergies, arthritis, asthma, erectile dysfunction, high cholesterol, smoking cessation, depression, and sleep disorder) or as "other." Televised DTCA exposure increased from 2003 to 2007 and then declined 43% by 2011, to 111 monthly prescription drug advertisements per household. The examined indications were associated with varying amounts and patterns of exposure, with greatest declines among medications for allergies and sleep disorders. Help-seeking advertisements comprised 10% of total exposure, with substantial variation by indication. Considerations of DTCA's effects on health care should take into account the shifting concentration of advertising across indications. Copyright © 2015 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  10. Trends in Exposure to Televised Prescription Drug Advertising, 2003–2011

    PubMed Central

    Kornfield, Rachel; Alexander, G. Caleb; Qato, Dima M.; Kim, Yoonsang; Hirsch, Jan D.; Emery, Sherry L.

    2015-01-01

    Introduction TV accounts for over half of pharmaceutical direct-to-consumer advertising (DTCA) spending in the U.S. The purpose of this study is to quantify average household exposure to branded and non-branded (help-seeking) televised prescription drug advertisements and describe variation over time and according to medication indication and geography. Methods In 2013, Nielsen TV ratings were compiled for prescription pharmaceutical advertising that aired between 2003 and 2011 for the top 75 U.S. media markets. All advertisements were coded as branded or help-seeking. Advertisements were further coded for one of eight prevalent indications (allergies, arthritis, asthma, erectile dysfunction, high cholesterol, smoking cessation, depression, and sleep disorder) or as “other.” Results Televised DTCA exposure increased from 2003 to 2007 and then declined 43% by 2011, to 111 monthly prescription drug advertisements per household. The examined indications were associated with varying amounts and patterns of exposure, with greatest declines among medications for allergies and sleep disorders. Help-seeking advertisements comprised 10% of total exposure, with substantial variation by indication. Conclusions Considerations of DTCA's effects on health care should take into account the shifting concentration of advertising across indications. PMID:25891057

  11. Preschoolers' Awareness of Television Advertising.

    ERIC Educational Resources Information Center

    Levin, Stephen R.; And Others

    1982-01-01

    The ability of 3-, 4-, and 5-year-old children to correctly identify videotaped segments as programs or commercials was examined. Results indicate that, when a task requiring minimal verbal response is used, preschoolers demonstrate an awareness of commercials as distinct from programs. (Author/MP)

  12. Role of tricuspid valve repair for moderate tricuspid regurgitation during minimally invasive mitral valve surgery.

    PubMed

    Pfannmueller, Bettina; Verevkin, Alexander; Borger, Michael Andrew; Mende, Meinhard; Davierwala, Piroze; Garbade, Jens; Mohr, Friedrich Wilhelm; Misfeld, Martin

    2013-08-01

    The aim of this study was to investigate the impact of short- and mid-term survival of tricuspid valve (TV) repair versus conservative therapy in patients with preoperative moderate functional tricuspid regurgitation (TR) undergoing minimally invasive mitral valve (MV) surgery. Between January 2002 and December 2009, a total of 430 patients with pure mitral regurgitation and concomitant moderate TR underwent minimally invasive MV surgery for mitral regurgitation at the Leipzig Heart Center without (n = 336; group A) and with (n = 94; group B) TV surgery. Mean age was 66.7 ± 10.3 years, mean LVEF was 58.0 ± 13.8%, and 206 patients (47.9%) were male. Average logEuroSCORE was 12.4 ± 11.4%. Follow-up was on average 4.6 ± 2.4 years and 97% completed. Predischarge echocardiography showed no or mild TR in 51.1% of patients in group A versus 84.2% of patients in group B (p < 0.01). Overall 30-day mortality was 2.8% with no differences between both groups. Five-year survival was 82.9 ± 4.1% for patients with TV repair versus 85.0 ± 2.2% for patients without TV repair (p = 0.1) and it was 85.7 ± 3.3% in patients with moderate and more postoperative TR versus 90.1 ± 2.5% in patients with less than moderate postoperative TR (p = 0.08). Five-year freedom from TV-related reoperation was 98.8 ± 0.7% for patients in group A versus 98.9 ± 0.1% for patients in group B (p = 0.8). Patients undergoing MV surgery with moderate functional TR do not experience increased perioperative complication rates when a concomitant TV repair is performed. Our observations, combined with those of other groups, support current recommendations to perform concomitant TV repair in such patients, particularly if tricuspid annular dilation is present. Georg Thieme Verlag KG Stuttgart · New York.

  13. 16 CFR 1115.26 - Guidelines and policies.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... SUBSTANTIAL PRODUCT HAZARD REPORTS Guidelines and Requirements for Mandatory Recall Notices § 1115.26... minimize the use of highly technical or legal terminology. (3) A recall notice should be targeted and...; (ii) Computer, radio, television, or other electronic transmission or medium; (iii) Video news release...

  14. 16 CFR 1115.26 - Guidelines and policies.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... SUBSTANTIAL PRODUCT HAZARD REPORTS Guidelines and Requirements for Mandatory Recall Notices § 1115.26... minimize the use of highly technical or legal terminology. (3) A recall notice should be targeted and...; (ii) Computer, radio, television, or other electronic transmission or medium; (iii) Video news release...

  15. A Weighted Difference of Anisotropic and Isotropic Total Variation for Relaxed Mumford-Shah Image Segmentation

    DTIC Science & Technology

    2016-05-01

    norm does not cap - ture the geometry completely. The L1−L2 in (c) does a better job than TV while L1 in (b) and L1−0.5L2 in (d) capture the squares most...and isotropic total variation (TV) norms into a relaxed formu- lation of the two phase Mumford-Shah (MS) model for image segmentation. We show...results exceeding those obtained by the MS model when using the standard TV norm to regular- ize partition boundaries. In particular, examples illustrating

  16. 16 CFR § 1115.26 - Guidelines and policies.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... REGULATIONS SUBSTANTIAL PRODUCT HAZARD REPORTS Guidelines and Requirements for Mandatory Recall Notices § 1115... minimize the use of highly technical or legal terminology. (3) A recall notice should be targeted and...; (ii) Computer, radio, television, or other electronic transmission or medium; (iii) Video news release...

  17. Compressed sensing with gradient total variation for low-dose CBCT reconstruction

    NASA Astrophysics Data System (ADS)

    Seo, Chang-Woo; Cha, Bo Kyung; Jeon, Seongchae; Huh, Young; Park, Justin C.; Lee, Byeonghun; Baek, Junghee; Kim, Eunyoung

    2015-06-01

    This paper describes the improvement of convergence speed with gradient total variation (GTV) in compressed sensing (CS) for low-dose cone-beam computed tomography (CBCT) reconstruction. We derive a fast algorithm for the constrained total variation (TV)-based a minimum number of noisy projections. To achieve this task we combine the GTV with a TV-norm regularization term to promote an accelerated sparsity in the X-ray attenuation characteristics of the human body. The GTV is derived from a TV and enforces more efficient computationally and faster in convergence until a desired solution is achieved. The numerical algorithm is simple and derives relatively fast convergence. We apply a gradient projection algorithm that seeks a solution iteratively in the direction of the projected gradient while enforcing a non-negatively of the found solution. In comparison with the Feldkamp, Davis, and Kress (FDK) and conventional TV algorithms, the proposed GTV algorithm showed convergence in ≤18 iterations, whereas the original TV algorithm needs at least 34 iterations in reducing 50% of the projections compared with the FDK algorithm in order to reconstruct the chest phantom images. Future investigation includes improving imaging quality, particularly regarding X-ray cone-beam scatter, and motion artifacts of CBCT reconstruction.

  18. Multiplicative noise removal through fractional order tv-based model and fast numerical schemes for its approximation

    NASA Astrophysics Data System (ADS)

    Ullah, Asmat; Chen, Wen; Khan, Mushtaq Ahmad

    2017-07-01

    This paper introduces a fractional order total variation (FOTV) based model with three different weights in the fractional order derivative definition for multiplicative noise removal purpose. The fractional-order Euler Lagrange equation which is a highly non-linear partial differential equation (PDE) is obtained by the minimization of the energy functional for image restoration. Two numerical schemes namely an iterative scheme based on the dual theory and majorization- minimization algorithm (MMA) are used. To improve the restoration results, we opt for an adaptive parameter selection procedure for the proposed model by applying the trial and error method. We report numerical simulations which show the validity and state of the art performance of the fractional-order model in visual improvement as well as an increase in the peak signal to noise ratio comparing to corresponding methods. Numerical experiments also demonstrate that MMAbased methodology is slightly better than that of an iterative scheme.

  19. Low-altitude acceleration of auroral electrons during breakup observed by a mother-daughter rocket

    NASA Technical Reports Server (NTRS)

    Johnstone, A. D.; Davis, T. N.

    1974-01-01

    By the use of a mother-daughter rocket combination and ground-based observations with television, time and space variations are resolved in particle measurements in breakup aurora. The spectral variations measured during a temporal variation in the aurora can be explained by a nearly uniform acceleration of all the electrons such as would be caused by an electric potential drop along the magnetic field lines. Many other explanations can be eliminated.

  20. MO-DE-207A-10: One-Step CT Reconstruction for Metal Artifact Reduction by a Modification of Penalized Weighted Least-Squares (PWLS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, H; Chen, J

    Purpose: Metal objects create severe artifacts in kilo-voltage (kV) CT image reconstructions due to the high attenuation coefficients of high atomic number objects. Most of the techniques devised to reduce this artifact utilize a two-step approach, which do not reliably yield the qualified reconstructed images. Thus, for accuracy and simplicity, this work presents a one-step reconstruction method based on a modified penalized weighted least-squares (PWLS) technique. Methods: Existing techniques for metal artifact reduction mostly adopt a two-step approach, which conduct additional reconstruction with the modified projection data from the initial reconstruction. This procedure does not consistently perform well due tomore » the uncertainties in manipulating the metal-contaminated projection data by thresholding and linear interpolation. This study proposes a one-step reconstruction process using a new PWLS operation with total-variation (TV) minimization, while not manipulating the projection. The PWLS for CT reconstruction has been investigated using a pre-defined weight, based on the variance of the projection datum at each detector bin. It works well when reconstructing CT images from metal-free projection data, which does not appropriately penalize metal-contaminated projection data. The proposed work defines the weight at each projection element under the assumption of a Poisson random variable. This small modification using element-wise penalization has a large impact in reducing metal artifacts. For evaluation, the proposed technique was assessed with two noisy, metal-contaminated digital phantoms, against the existing PWLS with TV minimization and the two-step approach. Result: The proposed PWLS with TV minimization greatly improved the metal artifact reduction, relative to the other techniques, by watching the results. Numerically, the new approach lowered the normalized root-mean-square error about 30 and 60% for the two cases, respectively, compared to the two-step method. Conclusion: A new PWLS operation shows promise for improving metal artifact reduction in CT imaging, as well as simplifying the reconstructing procedure.« less

  1. Video requirements for remote medical diagnosis

    NASA Technical Reports Server (NTRS)

    Davis, J. G.

    1974-01-01

    Minimal television system requirements for medical telediagnosis were studied. The experiment was conducted with the aid of a simulated telemedicine system. The first step involved making high quality videotape recordings of actual medical examinations conducted by a skilled nurse under the direction of a physician watching on closed circuit television. These recordings formed the baseline for the study. Next, these videotape recordings were electronically degraded to simulate television systems of less than broadcast quality. Finally, the baseline and degraded video recordings were shown (via a statistically randomized procedure) to a large number of physicians who attempted to reach a correct medical diagnosis and to visually recognize key physical signs for each patient. By careful scoring and analysis of the results of these viewings, the pictorial and diagnostic limitations as a function of technical video characteristics were to be defined.

  2. Total variation optimization for imaging through turbid media with transmission matrix

    NASA Astrophysics Data System (ADS)

    Gong, Changmei; Shao, Xiaopeng; Wu, Tengfei; Liu, Jietao; Zhang, Jianqi

    2016-12-01

    With the transmission matrix (TM) of the whole optical system measured, the image of the object behind a turbid medium can be recovered from its speckle field by means of an image reconstruction algorithm. Instead of Tikhonov regularization algorithm (TRA), the total variation minimization by augmented Lagrangian and alternating direction algorithms (TVAL3) is introduced to recover object images. As a total variation (TV)-based approach, TVAL3 allows to effectively damp more noise and preserve more edges compared with TRA, thus providing more outstanding image quality. Different levels of detector noise and TM-measurement noise are successively added to analyze the antinoise performance of these two algorithms. Simulation results show that TVAL3 is able to recover more details and suppress more noise than TRA under different noise levels, thus providing much more excellent image quality. Furthermore, whether it be detector noise or TM-measurement noise, the reconstruction images obtained by TVAL3 at SNR=15 dB are far superior to those by TRA at SNR=50 dB.

  3. MO-FG-CAMPUS-IeP2-04: Multiple Penalties with Different Orders for Structure Adaptive CBCT Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, Q; Cheng, P; Tan, S

    2016-06-15

    Purpose: To combine total variation (TV) and Hessian penalty in a structure adaptive way for cone-beam CT (CBCT) reconstruction. Methods: TV is a widely used first order penalty with good ability in suppressing noise and preserving edges but leads to the staircase effect in regions with smooth intensity transition. The second order Hessian penalty can effectively suppress the staircase effect with extra cost of blurring object edges. To take the best of both penalties we proposed a novel method to combine both for CBCT reconstruction in a structure adaptive way. The proposed method adaptively determined the weight of each penaltymore » according to the geometry of local regions. An specially-designed exponent term with image gradient involved was used to characterize the local geometry such that the weights for Hessian and TV were 1 and 0 respectively at uniform local regions and 0 and 1 at edge regions. For other local regions the weights varied from 0 to 1. The objective functional was minimized using the majorzationminimization approach. We evaluated the proposed method on a modified 3D shepp-logan and a CatPhan 600 phantom. The full-width-at-halfmaximum (FWHM) and contrast-to-noise (CNR) were calculated. Results: For 3D shepp-logan the reconstructed images using TV had an obvious staircase effect while those using the proposed method and Hessian preserved the smooth transition regions well. FWHMs of the proposed method TV and Hessian penalty were 1.75 1.61 and 3.16 respectively, indicating that both TV and the proposed method is able to preserve edges. For CatPhan 600 CNR values of the proposed method were similar to those of TV and Hessian. Conclusion: The proposed method retains favorable properties of TV like preserving edges and also has the ability in better preserving gradual transition structure as Hessian does. All methods performs similarly in suppressing noise. This work was supported in part by National Natural Science Foundation of China (NNSFC) under Grant Nos.60971112 and 61375018 grants from the Cancer Prevention and Research Institute of Texas (RP130109 and RP110562-P2) National Institute of Biomedical Imaging and Bioengineering (R01 EB020366) and a grant from the American Cancer Society (RSG-13-326-01-CCE).« less

  4. Earned and Unearned Degrees, Earned and Unearned Teaching Certificates: Implications for Education.

    ERIC Educational Resources Information Center

    Shaughnessy, Michael F.; Gaedke, Billy

    This article discusses the impact of instructional television, directed study courses, and other alternative teacher certification methods. Colleges and universities are becoming aware of nontraditional programs that require minimal, if any, time on campus or direct contact with instructors. Soon, there will be a proliferation of Internet courses.…

  5. Minimize Subjective Theory, Maximize Authentic Experience in the Teaching of French Civilization.

    ERIC Educational Resources Information Center

    Corredor, Eva L.

    A program developed to teach French civilization and modern France at the U.S. Naval Academy (Annapolis, Maryland) was designed to take advantage of readily available, relatively sophisticated technology for classroom instruction. The hardware used includes a satellite earth station that receives regular television broadcasts from France, a…

  6. A Touch of...Class!

    ERIC Educational Resources Information Center

    Tweedie, Karen, Ed.

    1987-01-01

    Games for use in the second-language classroom are suggested, including variations on tic-tac-toe and snakes and ladders, races, board games based on American television programs, math activities, and a classroom mystery. (MSE)

  7. Solid state television camera (CCD-buried channel)

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The development of an all solid state television camera, which uses a buried channel charge coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array is utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control (i.e., ALC and AGC) techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a deliverable solid state TV camera which addressed the program requirements for a prototype qualifiable to space environment conditions.

  8. Solid state television camera (CCD-buried channel), revision 1

    NASA Technical Reports Server (NTRS)

    1977-01-01

    An all solid state television camera was designed which uses a buried channel charge coupled device (CCD) as the image sensor. A 380 x 488 element CCD array is utilized to ensure compatibility with 525-line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (1) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (2) techniques for the elimination or suppression of CCD blemish effects, and (3) automatic light control and video gain control techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a deliverable solid state TV camera which addressed the program requirements for a prototype qualifiable to space environment conditions.

  9. Solid state, CCD-buried channel, television camera study and design

    NASA Technical Reports Server (NTRS)

    Hoagland, K. A.; Balopole, H.

    1976-01-01

    An investigation of an all solid state television camera design, which uses a buried channel charge-coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array was utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a design which addresses the program requirements for a deliverable solid state TV camera.

  10. Statistical Interior Tomography

    PubMed Central

    Xu, Qiong; Wang, Ge; Sieren, Jered; Hoffman, Eric A.

    2011-01-01

    This paper presents a statistical interior tomography (SIT) approach making use of compressed sensing (CS) theory. With the projection data modeled by the Poisson distribution, an objective function with a total variation (TV) regularization term is formulated in the maximization of a posteriori (MAP) framework to solve the interior problem. An alternating minimization method is used to optimize the objective function with an initial image from the direct inversion of the truncated Hilbert transform. The proposed SIT approach is extensively evaluated with both numerical and real datasets. The results demonstrate that SIT is robust with respect to data noise and down-sampling, and has better resolution and less bias than its deterministic counterpart in the case of low count data. PMID:21233044

  11. Recovering fine details from under-resolved electron tomography data using higher order total variation ℓ 1 regularization

    DOE PAGES

    Sanders, Toby; Gelb, Anne; Platte, Rodrigo B.; ...

    2017-01-03

    Over the last decade or so, reconstruction methods using ℓ 1 regularization, often categorized as compressed sensing (CS) algorithms, have significantly improved the capabilities of high fidelity imaging in electron tomography. The most popular ℓ 1 regularization approach within electron tomography has been total variation (TV) regularization. In addition to reducing unwanted noise, TV regularization encourages a piecewise constant solution with sparse boundary regions. In this paper we propose an alternative ℓ 1 regularization approach for electron tomography based on higher order total variation (HOTV). Like TV, the HOTV approach promotes solutions with sparse boundary regions. In smooth regions however,more » the solution is not limited to piecewise constant behavior. We demonstrate that this allows for more accurate reconstruction of a broader class of images – even those for which TV was designed for – particularly when dealing with pragmatic tomographic sampling patterns and very fine image features. In conclusion, we develop results for an electron tomography data set as well as a phantom example, and we also make comparisons with discrete tomography approaches.« less

  12. Students' Perceived Challenges in an Online Collaborative Learning Environment: A Case of Higher Learning Institutions in Nairobi, Kenya

    ERIC Educational Resources Information Center

    Muuro, Maina Elizaphan; Wagacha, Waiganjo Peter; Oboko, Robert; Kihoro, John

    2014-01-01

    Earlier forms of distance education were characterized by minimal social interaction like correspondence, television, video and radio. However, the World Wide Web (WWW) and online learning introduced the opportunity for much more social interaction, particularly among learners, and this has been further made possible through social media in Web…

  13. An image-guided radiotherapy decision support framework incorporating a Bayesian network and visualization tool.

    PubMed

    Hargrave, Catriona; Deegan, Timothy; Bednarz, Tomasz; Poulsen, Michael; Harden, Fiona; Mengersen, Kerrie

    2018-05-17

    To describe a Bayesian network (BN) and complementary visualization tool that aim to support decision-making during online cone-beam computed tomography (CBCT)-based image-guided radiotherapy (IGRT) for prostate cancer patients. The BN was created to represent relationships between observed prostate, proximal seminal vesicle (PSV), bladder and rectum volume variations, an image feature alignment score (FAS TV _ OAR ), delivered dose, and treatment plan compliance (TPC). Variables influencing tumor volume (TV) targeting accuracy such as intrafraction motion, and contouring and couch shift errors were also represented. A score of overall TPC (FAS global ) and factors such as image quality were used to inform the BN output node providing advice about proceeding with treatment. The BN was quantified using conditional probabilities generated from published studies, FAS TV _ OAR /global modeling, and a survey of IGRT decision-making practices. A new IGRT visualization tool (IGRT REV ), in the form of Mollweide projection plots, was developed to provide a global summary of residual errors after online CBCT-planning CT registration. Sensitivity and scenario analyses were undertaken to evaluate the performance of the BN and the relative influence of the network variables on TPC and the decision to proceed with treatment. The IGRT REV plots were evaluated in conjunction with the BN scenario testing, using additional test data generated from retrospective CBCT-planning CT soft-tissue registrations for 13/36 patients whose data were used in the FAS TV _ OAR /global modeling. Modeling of the TV targeting errors resulted in a very low probability of corrected distances between the CBCT and planning CT prostate or PSV volumes being within their thresholds. Strength of influence evaluation with and without the BN TV targeting error nodes indicated that rectum- and bladder-related network variables had the highest relative importance. When the TV targeting error nodes were excluded from the BN, TPC was sensitive to observed PSV and rectum variations while the decision to treat was sensitive to observed prostate and PSV variations. When root nodes were set so the PSV and rectum variations exceeded thresholds, the probability of low TPC increased to 40%. Prostate and PSV variations exceeding thresholds increased the likelihood of repositioning or repeating patient preparation to 43%. Scenario testing using the test data from 13 patients, demonstrated two cases where the BN provided increased high TPC probabilities, despite some of the prostate and PSV volume variation metrics not being within tolerance. The IGRT REV tool was effective in highlighting and quantifying where TV and OAR variations occurred, supporting the BN recommendation to reposition the patient or repeat their bladder and bowel preparation. In another case, the IGRT REV tool was also effective in highlighting where PSV volume variation significantly exceeded tolerance when the BN had indicated to proceed with treatment. This study has demonstrated that both the BN and IGRT REV plots are effective tools for inclusion in a decision support system for online CBCT-based IGRT for prostate cancer patients. Alternate approaches to modeling TV targeting errors need to be explored as well as extension of the BN to support offline IGRT decisions related to adaptive radiotherapy. © 2018 American Association of Physicists in Medicine.

  14. Performance evaluation of image denoising developed using convolutional denoising autoencoders in chest radiography

    NASA Astrophysics Data System (ADS)

    Lee, Donghoon; Choi, Sunghoon; Kim, Hee-Joung

    2018-03-01

    When processing medical images, image denoising is an important pre-processing step. Various image denoising algorithms have been developed in the past few decades. Recently, image denoising using the deep learning method has shown excellent performance compared to conventional image denoising algorithms. In this study, we introduce an image denoising technique based on a convolutional denoising autoencoder (CDAE) and evaluate clinical applications by comparing existing image denoising algorithms. We train the proposed CDAE model using 3000 chest radiograms training data. To evaluate the performance of the developed CDAE model, we compare it with conventional denoising algorithms including median filter, total variation (TV) minimization, and non-local mean (NLM) algorithms. Furthermore, to verify the clinical effectiveness of the developed denoising model with CDAE, we investigate the performance of the developed denoising algorithm on chest radiograms acquired from real patients. The results demonstrate that the proposed denoising algorithm developed using CDAE achieves a superior noise-reduction effect in chest radiograms compared to TV minimization and NLM algorithms, which are state-of-the-art algorithms for image noise reduction. For example, the peak signal-to-noise ratio and structure similarity index measure of CDAE were at least 10% higher compared to conventional denoising algorithms. In conclusion, the image denoising algorithm developed using CDAE effectively eliminated noise without loss of information on anatomical structures in chest radiograms. It is expected that the proposed denoising algorithm developed using CDAE will be effective for medical images with microscopic anatomical structures, such as terminal bronchioles.

  15. SparseBeads data: benchmarking sparsity-regularized computed tomography

    NASA Astrophysics Data System (ADS)

    Jørgensen, Jakob S.; Coban, Sophia B.; Lionheart, William R. B.; McDonald, Samuel A.; Withers, Philip J.

    2017-12-01

    Sparsity regularization (SR) such as total variation (TV) minimization allows accurate image reconstruction in x-ray computed tomography (CT) from fewer projections than analytical methods. Exactly how few projections suffice and how this number may depend on the image remain poorly understood. Compressive sensing connects the critical number of projections to the image sparsity, but does not cover CT, however empirical results suggest a similar connection. The present work establishes for real CT data a connection between gradient sparsity and the sufficient number of projections for accurate TV-regularized reconstruction. A collection of 48 x-ray CT datasets called SparseBeads was designed for benchmarking SR reconstruction algorithms. Beadpacks comprising glass beads of five different sizes as well as mixtures were scanned in a micro-CT scanner to provide structured datasets with variable image sparsity levels, number of projections and noise levels to allow the systematic assessment of parameters affecting performance of SR reconstruction algorithms6. Using the SparseBeads data, TV-regularized reconstruction quality was assessed as a function of numbers of projections and gradient sparsity. The critical number of projections for satisfactory TV-regularized reconstruction increased almost linearly with the gradient sparsity. This establishes a quantitative guideline from which one may predict how few projections to acquire based on expected sample sparsity level as an aid in planning of dose- or time-critical experiments. The results are expected to hold for samples of similar characteristics, i.e. consisting of few, distinct phases with relatively simple structure. Such cases are plentiful in porous media, composite materials, foams, as well as non-destructive testing and metrology. For samples of other characteristics the proposed methodology may be used to investigate similar relations.

  16. Should image rotation be addressed during routine cone-beam CT quality assurance?

    NASA Astrophysics Data System (ADS)

    Ayan, Ahmet S.; Lin, Haibo; Yeager, Caitlyn; Deville, Curtiland; McDonough, James; Zhu, Timothy C.; Anderson, Nathan; Bar Ad, Voichita; Lu, Hsiao-Ming; Both, Stefan

    2013-02-01

    The purpose of this study is to investigate whether quality assurance (QA) for cone-beam computed tomography (CBCT) image rotation is necessary in order to ensure the accuracy of CBCT based image-guided radiation therapy (IGRT) and adaptive radiotherapy (ART). Misregistration of angular coordinates during CBCT acquisition may lead to a rotated reconstructed image. If target localization is performed based on this image, an under- or over-dosage of the target volume (TV) and organs at risk (OARs) may occur. Therefore, patient CT image sets were rotated by 1° up to 3° and the treatment plans were recalculated to quantify changes in dose-volume histograms. A computer code in C++ was written to model the TV displacement and overlap area of an ellipse shape at the target and dose prescription levels corresponding to the image rotation. We investigated clinical scenarios in IGRT and ART in order to study the implications of image rotation on dose distributions for: (1) lateral TV and isocenter (SBRT), (2) central TV and isocenter (IMRT), (3) lateral TV and isocenter (IMRT). Mathematical analysis showed the dose coverage of TV depends on its shape, size, location, and orientation relative to the isocenter. Evaluation of three first scenario for θ = 1° showed variations in TV D95 in the context of IGRT and ART when compared to the original plan were within 2.7 ± 2.6% and 7.7 ± 6.9% respectively while variations in the second and third scenarios were less significant (<0.5%) for the angular range evaluated. However a larger degree of variation was found in terms of minimum and maximum doses for target and OARs. The rotation of CBCT image data sets may have significant dosimetric consequences in IGRT and ART. The TV's location relative to isocenter and shape determine the extent of alterations in dose indicators. Our findings suggest that a CBCT QA criterion of 1° would be a reasonable action level to ensure accurate dose delivery.

  17. Energy use of televisions and video cassette recorders in the U.S.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meier, Alan; Rosen, Karen

    1999-03-01

    In an effort to more accurately determine nationwide energy consumption, the U.S. Department of Energy has recently commissioned studies with the goal of improving its understanding of the energy use of appliances in the miscellaneous end-use category. This study presents an estimate of the residential energy consumption of two of the most common domestic appliances in the miscellaneous end-use category: color televisions (TVs) and video cassette recorders (VCRs). The authors used a bottom-up approach in estimating national TV and VCR energy consumption. First, they obtained estimates of stock and usage from national surveys, while TV and VCR power measurements andmore » other data were recorded at repair and retail shops. Industry-supplied shipment and sales distributions were then used to minimize bias in the power measurement samples. To estimate national TV and VCR energy consumption values, ranges of power draw and mode usage were created to represent situations in homes with more than one unit. Average energy use values for homes with one unit, two units, etc. were calculated and summed to provide estimates of total national TV and VCR energy consumption.« less

  18. User's manual for flight Simulator Display System (FSDS)

    NASA Technical Reports Server (NTRS)

    Egerdahl, C. C.

    1979-01-01

    The capabilities of the flight simulator display system (FSDS) are described. FSDS is a color raster scan display generator designed to meet the special needs of Flight Simulation Laboratories. The FSDS can update (revise) the images it generates every 16.6 mS, with limited support from a host processor. This corresponds to the standard TV vertical rate of 60 Hertz, and allows the system to carry out display functions in a time critical environment. Rotation of a complex image in the television raster with minimal hardware is possible with the system.

  19. Spatially adapted second-order total generalized variational image deblurring model under impulse noise

    NASA Astrophysics Data System (ADS)

    Zhong, Qiu-Xiang; Wu, Chuan-Sheng; Shu, Qiao-Ling; Liu, Ryan Wen

    2018-04-01

    Image deblurring under impulse noise is a typical ill-posed problem which requires regularization methods to guarantee high-quality imaging. L1-norm data-fidelity term and total variation (TV) regularizer have been combined to contribute the popular regularization method. However, the TV-regularized variational image deblurring model often suffers from the staircase-like artifacts leading to image quality degradation. To enhance image quality, the detailpreserving total generalized variation (TGV) was introduced to replace TV to eliminate the undesirable artifacts. The resulting nonconvex optimization problem was effectively solved using the alternating direction method of multipliers (ADMM). In addition, an automatic method for selecting spatially adapted regularization parameters was proposed to further improve deblurring performance. Our proposed image deblurring framework is able to remove blurring and impulse noise effects while maintaining the image edge details. Comprehensive experiments have been conducted to demonstrate the superior performance of our proposed method over several state-of-the-art image deblurring methods.

  20. Antismoking television advertising and socioeconomic variations in calls to Quitline.

    PubMed

    Siahpush, Mohammad; Wakefield, Melanie; Spittal, Matt; Durkin, Sarah

    2007-04-01

    To assess the socioeconomic variations in call rates to the Quitline (Victoria, Australia) and in the impact of anti-tobacco television advertising on call rates. The outcome measure was the number of calls to the Quitline in Victoria for each week for each socioeconomic group for the period January 2001 to March 2004. Socioeconomic status (SES) was derived from the caller's postcode using the Index of Socioeconomic Disadvantage provided by the Australian Bureau of Statistics. The exposure measure was weekly Target Audience Rating Points (TARPs, a standard measure of television advertising weight) for anti-tobacco advertising broadcast in Victoria over the same period. Negative binomial regression was used to examine the interaction of SES and TARPs in their effect on the number of Quitline calls. SES and call rates were positively associated. Adjusted call rate was 57% (95% CI 45% to 69%) higher in the highest than the lowest SES quintile. SES differences in call rates were stable over time. In the study period, the effect of the presence or increasing levels of antismoking TARPs on call rates did not vary across categories of SES. In the study period, different SES groups had a similar level of responsiveness to antismoking television advertisements, at least as measured by the rate of calls to the Quitline. However, the present media campaigns are not likely to diminish SES differences in call rates, and more needs to be done to encourage disadvantaged groups to call the Quitline.

  1. Antismoking television advertising and socioeconomic variations in calls to Quitline

    PubMed Central

    Siahpush, Mohammad; Wakefield, Melanie; Spittal, Matt; Durkin, Sarah

    2007-01-01

    Objective To assess the socioeconomic variations in call rates to the Quitline (Victoria, Australia) and in the impact of anti‐tobacco television advertising on call rates. Design The outcome measure was the number of calls to the Quitline in Victoria for each week for each socioeconomic group for the period January 2001 to March 2004. Socioeconomic status (SES) was derived from the caller's postcode using the Index of Socioeconomic Disadvantage provided by the Australian Bureau of Statistics. The exposure measure was weekly Target Audience Rating Points (TARPs, a standard measure of television advertising weight) for anti‐tobacco advertising broadcast in Victoria over the same period. Negative binomial regression was used to examine the interaction of SES and TARPs in their effect on the number of Quitline calls. Results SES and call rates were positively associated. Adjusted call rate was 57% (95% CI 45% to 69%) higher in the highest than the lowest SES quintile. SES differences in call rates were stable over time. In the study period, the effect of the presence or increasing levels of antismoking TARPs on call rates did not vary across categories of SES. Conclusions In the study period, different SES groups had a similar level of responsiveness to antismoking television advertisements, at least as measured by the rate of calls to the Quitline. However, the present media campaigns are not likely to diminish SES differences in call rates, and more needs to be done to encourage disadvantaged groups to call the Quitline. PMID:17372288

  2. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization

    NASA Astrophysics Data System (ADS)

    Kim, Hojin; Li, Ruijiang; Lee, Rena; Xing, Lei

    2015-03-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating non-uniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans.

  3. An interior-point method for total variation regularized positron emission tomography image reconstruction

    NASA Astrophysics Data System (ADS)

    Bai, Bing

    2012-03-01

    There has been a lot of work on total variation (TV) regularized tomographic image reconstruction recently. Many of them use gradient-based optimization algorithms with a differentiable approximation of the TV functional. In this paper we apply TV regularization in Positron Emission Tomography (PET) image reconstruction. We reconstruct the PET image in a Bayesian framework, using Poisson noise model and TV prior functional. The original optimization problem is transformed to an equivalent problem with inequality constraints by adding auxiliary variables. Then we use an interior point method with logarithmic barrier functions to solve the constrained optimization problem. In this method, a series of points approaching the solution from inside the feasible region are found by solving a sequence of subproblems characterized by an increasing positive parameter. We use preconditioned conjugate gradient (PCG) algorithm to solve the subproblems directly. The nonnegativity constraint is enforced by bend line search. The exact expression of the TV functional is used in our calculations. Simulation results show that the algorithm converges fast and the convergence is insensitive to the values of the regularization and reconstruction parameters.

  4. Nutritional status and the influence of TV consumption on female body size ideals in populations recently exposed to the media.

    PubMed

    Jucker, Jean-Luc; Thornborrow, Tracey; Beierholm, Ulrik; Burt, D Michael; Barton, Robert A; Evans, Elizabeth H; Jamieson, Mark A; Tovée, Martin J; Boothroyd, Lynda G

    2017-08-16

    Television consumption influences perceptions of attractive female body size. However, cross-cultural research examining media influence on body ideals is typically confounded by differences in the availability of reliable and diverse foodstuffs. 112 participants were recruited from 3 Nicaraguan villages that differed in television consumption and nutritional status, such that the contribution of both factors could be revealed. Participants completed a female figure preference task, reported their television consumption, and responded to several measures assessing nutritional status. Communities with higher television consumption and/or higher nutritional status preferred thinner female bodies than communities with lower television consumption and/or lower nutritional status. Bayesian mixed models estimated the plausible range of effects for television consumption, nutritional status, and other relevant variables on individual preferences. The model explained all meaningful differences between our low-nutrition villages, and television consumption, after sex, was the most likely of these predictors to contribute to variation in preferences (probability mass >95% when modelling only variables with zero-order associations with preferences, but only 90% when modelling all possible predictors). In contrast, we found no likely link with nutritional status. We thus found evidence that where media access and nutritional status are confounded, media is the more likely predictor of body ideals.

  5. 76 FR 31958 - Information Collection Being Submitted for Review and Approval to the Office of Management and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ... enhance the quality, utility, and clarity of the information collected; (d) ways to minimize the burden of... frequencies. Section 90.545(c)(1) requires that public safety applicants select one of three ways to meet TV... engineering study to justify other separations; or (3) obtain concurrence from the applicable TV/DTV station(s...

  6. Serial-to-parallel color-TV converter

    NASA Technical Reports Server (NTRS)

    Doak, T. W.; Merwin, R. B.; Zuckswert, S. E.; Sepper, W.

    1976-01-01

    Solid analog-to-digital converter eliminates flicker and problems with time base stability and gain variation in sequential color TV cameras. Device includes 3-bit delta modulator; two-field memory; timing, switching, and sync network; and three 3-bit delta demodulators

  7. Television monitor field shifter and an opto-electronic method for obtaining a stereo image of optimal depth resolution and reduced depth distortion on a single screen

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B. (Inventor)

    1989-01-01

    A method and apparatus is developed for obtaining a stereo image with reduced depth distortion and optimum depth resolution. Static and dynamic depth distortion and depth resolution tradeoff is provided. Cameras obtaining the images for a stereo view are converged at a convergence point behind the object to be presented in the image, and the collection-surface-to-object distance, the camera separation distance, and the focal lengths of zoom lenses for the cameras are all increased. Doubling the distances cuts the static depth distortion in half while maintaining image size and depth resolution. Dynamic depth distortion is minimized by panning a stereo view-collecting camera system about a circle which passes through the convergence point and the camera's first nodal points. Horizontal field shifting of the television fields on a television monitor brings both the monitor and the stereo views within the viewer's limit of binocular fusion.

  8. Vulnerability to the impact of temperature variability on mortality in 31 major Chinese cities.

    PubMed

    Yang, Jun; Zhou, Maigeng; Li, Mengmeng; Liu, Xiaobo; Yin, Peng; Sun, Qinghua; Wang, Jun; Wu, Haixia; Wang, Boguang; Liu, Qiyong

    2018-08-01

    Few studies have analyzed the health effects of temperature variability (TV) accounting for both interday and intraday variations in ambient temperature. In this study, TV was defined as the standard deviations of the daily minimum and maximum temperature during different exposure days. Distributed lag non-linear Poisson regression model was used to examine the city-specific effect of TV on mortality in 31 Chinese municipalities and provincial capital cities. The national estimate was pooled through a meta-analysis based on the restricted maximum likelihood estimation. To assess effect modification on TV-mortality association by individual characteristics, stratified analyses were further fitted. Potential effect modification by city characteristics was performed through a meta-regression analysis. In total, 259 million permanent residents and 4,481,090 non-accidental deaths were covered in this study. The effect estimates of TV on mortality were generally increased by longer exposure days. A 1 °C increase in TV at 0-7 days' exposure was associated with a 0.60% (95% CI: 0.25-0.94%), 0.65% (0.24-1.05%), 0.82% (0.29-1.36%), 0.86% (0.42-1.31%), 0.98% (0.57-1.39%) and 0.54% (-0.11-1.20%) increase in non-accidental, cardiovascular, IHD, stroke, respiratory and COPD mortalities, respectively. Those with lower levels of educational attainment were significantly susceptible to TV. Cities with dense population, higher mean temperatures, and relative humidity and lower diurnal temperature ranges also had higher mortality risks caused by TV. This study demonstrated that TV had considerable health effects. An early warning system to alert residents about large temperature variations is recommended, which may have a significant impact on the community awareness and public health. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Determinants of Network News Coverage of the Oil Industry during the Late 1970s.

    ERIC Educational Resources Information Center

    Erfle, Stephen; McMillan, Henry

    1989-01-01

    Examines which firms and products best predict media coverage of the oil industry. Reports that price variations in testing oil and gasoline correlate with the extent of news coverage provided by network television. (MM)

  10. A Model of Regularization Parameter Determination in Low-Dose X-Ray CT Reconstruction Based on Dictionary Learning.

    PubMed

    Zhang, Cheng; Zhang, Tao; Zheng, Jian; Li, Ming; Lu, Yanfei; You, Jiali; Guan, Yihui

    2015-01-01

    In recent years, X-ray computed tomography (CT) is becoming widely used to reveal patient's anatomical information. However, the side effect of radiation, relating to genetic or cancerous diseases, has caused great public concern. The problem is how to minimize radiation dose significantly while maintaining image quality. As a practical application of compressed sensing theory, one category of methods takes total variation (TV) minimization as the sparse constraint, which makes it possible and effective to get a reconstruction image of high quality in the undersampling situation. On the other hand, a preliminary attempt of low-dose CT reconstruction based on dictionary learning seems to be another effective choice. But some critical parameters, such as the regularization parameter, cannot be determined by detecting datasets. In this paper, we propose a reweighted objective function that contributes to a numerical calculation model of the regularization parameter. A number of experiments demonstrate that this strategy performs well with better reconstruction images and saving of a large amount of time.

  11. Computerized tomography with total variation and with shearlets

    NASA Astrophysics Data System (ADS)

    Garduño, Edgar; Herman, Gabor T.

    2017-04-01

    To reduce the x-ray dose in computerized tomography (CT), many constrained optimization approaches have been proposed aiming at minimizing a regularizing function that measures a lack of consistency with some prior knowledge about the object that is being imaged, subject to a (predetermined) level of consistency with the detected attenuation of x-rays. One commonly investigated regularizing function is total variation (TV), while other publications advocate the use of some type of multiscale geometric transform in the definition of the regularizing function, a particular recent choice for this is the shearlet transform. Proponents of the shearlet transform in the regularizing function claim that the reconstructions so obtained are better than those produced using TV for texture preservation (but may be worse for noise reduction). In this paper we report results related to this claim. In our reported experiments using simulated CT data collection of the head, reconstructions whose shearlet transform has a small ℓ 1-norm are not more efficacious than reconstructions that have a small TV value. Our experiments for making such comparisons use the recently-developed superiorization methodology for both regularizing functions. Superiorization is an automated procedure for turning an iterative algorithm for producing images that satisfy a primary criterion (such as consistency with the observed measurements) into its superiorized version that will produce results that, according to the primary criterion are as good as those produced by the original algorithm, but in addition are superior to them according to a secondary (regularizing) criterion. The method presented for superiorization involving the ℓ 1-norm of the shearlet transform is novel and is quite general: It can be used for any regularizing function that is defined as the ℓ 1-norm of a transform specified by the application of a matrix. Because in the previous literature the split Bregman algorithm is used for similar purposes, a section is included comparing the results of the superiorization algorithm with the split Bregman algorithm.

  12. Analysis and design of stereoscopic display in stereo television endoscope system

    NASA Astrophysics Data System (ADS)

    Feng, Dawei

    2008-12-01

    Many 3D displays have been proposed for medical use. When we design and evaluate new system, there are three demands from surgeons. Priority is the precision. Secondly, displayed images should be easy to understand, In addition, surgery lasts hours and hours, they do not like fatiguing display. The stereo television endoscope researched in this paper make celiac viscera image on the photosurface of the left and right CCD by imitating human binocular stereo vision effect by using the double-optical lines system. The left and right video signal will be processed by frequency multiplication and display on the monitor, people can observe the stereo image which has depth impression by using a polarized LCD screen and a pair of polarized glasses. Clinical experiments show that by using the stereo TV endoscope people can make minimally invasive surgery more safe and reliable, and can shorten the operation time, and can improve the operation accuracy.

  13. Stereoscopic Configurations To Minimize Distortions

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B.

    1991-01-01

    Proposed television system provides two stereoscopic displays. Two-camera, two-monitor system used in various camera configurations and with stereoscopic images on monitors magnified to various degrees. Designed to satisfy observer's need to perceive spatial relationships accurately throughout workspace or to perceive them at high resolution in small region of workspace. Potential applications include industrial, medical, and entertainment imaging and monitoring and control of telemanipulators, telerobots, and remotely piloted vehicles.

  14. Genre-Specific Cultivation Effects: Lagged Associations between Overall TV Viewing, Local TV News Viewing, and Fatalistic Beliefs about Cancer Prevention

    PubMed Central

    Niederdeppe, Jeff

    2014-01-01

    Cultivation theory and research has been criticized for its failure to consider variation in effects by genre, employ appropriate third-variable controls, and determine causal direction. Recent studies, controlling for a variety of demographic characteristics and media use variables, have found that exposure to local television (TV) newscasts is associated with a variety of problematic “real-world” beliefs. However, many of these studies have not adequately assessed causal direction. Redressing this limitation, we analyzed data from a two-wave national representative survey which permitted tests of lagged association between overall TV viewing, local TV news viewing, and fatalistic beliefs about cancer prevention. We first replicated the original cultivation effect and found a positive association between overall TV viewing at time 1 and increased fatalistic beliefs about cancer prevention at time 2. Analyses also provided evidence that local TV news viewing at time 1 predicts increased fatalistic beliefs about cancer prevention at time 2. There was little evidence for reverse causation in predicting changes in overall TV viewing or local TV news viewing. The paper concludes with a discussion of theoretical and practical implications of these findings. PMID:25605981

  15. Correlates of socio-economic inequalities in women's television viewing: a study of intrapersonal, social and environmental mediators.

    PubMed

    Teychenne, Megan; Ball, Kylie; Salmon, Jo

    2012-01-20

    Socio-economically disadvantaged women are at a greater risk of spending excess time engaged in television viewing, a behavior linked to several adverse health outcomes. However, the factors which explain socio-economic differences in television viewing are unknown. This study aimed to investigate the contribution of intrapersonal, social and environmental factors to mediating socio-economic (educational) inequalities in women's television viewing. Cross-sectional data were provided by 1,554 women (aged 18-65) who participated in the 'Socio-economic Status and Activity in Women study' of 2004. Based on an ecological framework, women self-reported their socio-economic position (highest education level), television viewing, as well as a number of potential intrapersonal (enjoyment of television viewing, preference for leisure-time sedentary behavior, depression, stress, weight status), social (social participation, interpersonal trust, social cohesion, social support for physical activity from friends and from family) and physical activity environmental factors (safety, aesthetics, distance to places of interest, and distance to physical activity facilities). Multiple mediating analyses showed that two intrapersonal factors (enjoyment of television viewing and weight status) and two social factors (social cohesion and social support from friends for physical activity) partly explained the educational inequalities in women's television viewing. No physical activity environmental factors mediated educational variations in television viewing. Acknowledging the cross-sectional nature of this study, these findings suggest that health promotion interventions aimed at reducing educational inequalities in television viewing should focus on intrapersonal and social strategies, particularly providing enjoyable alternatives to television viewing, weight-loss/management information, increasing social cohesion in the neighborhood and promoting friend support for activity.

  16. Investigation of an electronic image enhancer for radiographs

    NASA Technical Reports Server (NTRS)

    Vary, A.

    1972-01-01

    Radiographs of nuclear and aerospace components were studied with a closed-circuit television system to determine the advantages of electronic enhancement in radiographic nondestructive evaluation. The radiographic images were examined on a television monitor under various degrees of magnification and enhancement. The enhancement was accomplished by generating a video signal whose amplitude is proportional to the rate of change of density. Points, lines, edges, and other density variations that are faintly registered in the original image are rendered in sharp relief. Examples of the applications of this mode of enhancement are discussed together with the system's dynamic response and resolution.

  17. Investigation of an electronic image enhancer for radiographs.

    NASA Technical Reports Server (NTRS)

    Vary, A.

    1972-01-01

    Radiographs of nuclear and aerospace components were studied with a closed-circuit television system to determine the advantages of electronic enhancement in radiographic nondestructive evaluation. The radiographic images were examined on a television monitor under various degrees of magnification and enhancement. The enhancement was accomplished by generating a video signal whose amplitude is proportional to the rate of change of density. Points, lines, edges, and other density variations that are faintly registered in the original image are rendered in sharp relief. Examples of the applications of this mode of enhancement are discussed together with the system's dynamic response and resolution.

  18. Should image rotation be addressed during routine cone-beam CT quality assurance?

    PubMed

    Ayan, Ahmet S; Lin, Haibo; Yeager, Caitlyn; Deville, Curtiland; McDonough, James; Zhu, Timothy C; Anderson, Nathan; Bar Ad, Voichita; Lu, Hsiao-Ming; Both, Stefan

    2013-02-21

    The purpose of this study is to investigate whether quality assurance (QA) for cone-beam computed tomography (CBCT) image rotation is necessary in order to ensure the accuracy of CBCT based image-guided radiation therapy (IGRT) and adaptive radiotherapy (ART). Misregistration of angular coordinates during CBCT acquisition may lead to a rotated reconstructed image. If target localization is performed based on this image, an under- or over-dosage of the target volume (TV) and organs at risk (OARs) may occur. Therefore, patient CT image sets were rotated by 1° up to 3° and the treatment plans were recalculated to quantify changes in dose-volume histograms. A computer code in C++ was written to model the TV displacement and overlap area of an ellipse shape at the target and dose prescription levels corresponding to the image rotation. We investigated clinical scenarios in IGRT and ART in order to study the implications of image rotation on dose distributions for: (1) lateral TV and isocenter (SBRT), (2) central TV and isocenter (IMRT), (3) lateral TV and isocenter (IMRT). Mathematical analysis showed the dose coverage of TV depends on its shape, size, location, and orientation relative to the isocenter. Evaluation of three first scenario for θ = 1° showed variations in TV D95 in the context of IGRT and ART when compared to the original plan were within 2.7 ± 2.6% and 7.7 ± 6.9% respectively while variations in the second and third scenarios were less significant (<0.5%) for the angular range evaluated. However a larger degree of variation was found in terms of minimum and maximum doses for target and OARs. The rotation of CBCT image data sets may have significant dosimetric consequences in IGRT and ART. The TV's location relative to isocenter and shape determine the extent of alterations in dose indicators. Our findings suggest that a CBCT QA criterion of 1° would be a reasonable action level to ensure accurate dose delivery.

  19. Micro-CT image reconstruction based on alternating direction augmented Lagrangian method and total variation.

    PubMed

    Gopi, Varun P; Palanisamy, P; Wahid, Khan A; Babyn, Paul; Cooper, David

    2013-01-01

    Micro-computed tomography (micro-CT) plays an important role in pre-clinical imaging. The radiation from micro-CT can result in excess radiation exposure to the specimen under test, hence the reduction of radiation from micro-CT is essential. The proposed research focused on analyzing and testing an alternating direction augmented Lagrangian (ADAL) algorithm to recover images from random projections using total variation (TV) regularization. The use of TV regularization in compressed sensing problems makes the recovered image quality sharper by preserving the edges or boundaries more accurately. In this work TV regularization problem is addressed by ADAL which is a variant of the classic augmented Lagrangian method for structured optimization. The per-iteration computational complexity of the algorithm is two fast Fourier transforms, two matrix vector multiplications and a linear time shrinkage operation. Comparison of experimental results indicate that the proposed algorithm is stable, efficient and competitive with the existing algorithms for solving TV regularization problems. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Ionospheric reflection coefficient for television signals

    NASA Astrophysics Data System (ADS)

    From, W. R.

    1984-08-01

    It has been shown that the ionospherically reflected field strength for 50 MHz signals varies (statistically) in proportion to about the 18th power of f(0)E(s) at the midpoint between transmitter and receiver. This note is to point out that this observation provides support for the theory that the horizontal structure of E(s) is due to a horizontal variation in the wind shear rather than horizontal convergence of metallic ions or a horizontal variation in the metallic column content.

  1. Analysis of the Factors Affecting Men's Attitudes Toward Cosmetic Surgery: Body Image, Media Exposure, Social Network Use, Masculine Gender Role Stress and Religious Attitudes.

    PubMed

    Abbas, Ozan Luay; Karadavut, Ufuk

    2017-12-01

    Cosmetic surgery is no longer just for females. More men are opting for cosmetic procedures, with marked increases seen in both minimally invasive and surgical options over the last decade. Compared to females, relatively little work has specifically focused on factors predicting males' attitudes toward cosmetic surgery. Therefore, we evaluated a number of variables that may predict some facet of men's attitudes toward cosmetic surgery according to evidence reported in the literature METHODS: A total of 151 male patients who applied for a surgical or minimally invasive cosmetic surgery procedure (patient group) and 151 healthy male volunteers who do not desire any type of cosmetic procedure (control group) were asked to fill out questionnaires about measures of body image, media exposure (television and magazine), social network site use, masculine gender role stress and religious attitudes. Our findings showed that lower ratings of body image satisfaction, increased time spent watching television, more frequent social network site use and higher degrees of masculine gender role stress were all significant predictors of attitudes toward cosmetic surgery among males. The current study confirmed the importance of body image dissatisfaction as a predictor of the choice to undergo cosmetic procedure. More importantly, a new predictor of cosmetic procedure attitudes was identified, namely masculine gender role stress. Finally, we demonstrated the effects television exposure and social network site use in promoting acceptance of surgical and nonsurgical routes to appearance enhancement. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  2. A function space framework for structural total variation regularization with applications in inverse problems

    NASA Astrophysics Data System (ADS)

    Hintermüller, Michael; Holler, Martin; Papafitsoros, Kostas

    2018-06-01

    In this work, we introduce a function space setting for a wide class of structural/weighted total variation (TV) regularization methods motivated by their applications in inverse problems. In particular, we consider a regularizer that is the appropriate lower semi-continuous envelope (relaxation) of a suitable TV type functional initially defined for sufficiently smooth functions. We study examples where this relaxation can be expressed explicitly, and we also provide refinements for weighted TV for a wide range of weights. Since an integral characterization of the relaxation in function space is, in general, not always available, we show that, for a rather general linear inverse problems setting, instead of the classical Tikhonov regularization problem, one can equivalently solve a saddle-point problem where no a priori knowledge of an explicit formulation of the structural TV functional is needed. In particular, motivated by concrete applications, we deduce corresponding results for linear inverse problems with norm and Poisson log-likelihood data discrepancy terms. Finally, we provide proof-of-concept numerical examples where we solve the saddle-point problem for weighted TV denoising as well as for MR guided PET image reconstruction.

  3. Fighting Back: New Media and Military Operations

    DTIC Science & Technology

    2008-11-01

    combustible mix of 24/7 cable news, call-in radio and television programs, Internet bloggers and online websites, cell phones and iPods.”4 But, of...even individuals to affect strategic outcomes with minimal information infrastructure and little capital expenditure. Anyone with a camera cell phone and...areas of underdeveloped countries. The cell phone , however, as a means of mobile technology, is increasingly available worldwide and deserves discussion

  4. Building the case for independent monitoring of food advertising on Australian television.

    PubMed

    King, Lesley; Hebden, Lana; Grunseit, Anne; Kelly, Bridget; Chapman, Kathy

    2013-12-01

    To provide an independent monitoring report examining the ongoing impact of Australian self-regulatory pledges on food and drink advertising to children on commercial television. Analysis of food advertisements across comparable sample time periods in April/May 2006, 2007, 2009, 2010 and 2011. The main outcome measure comprised change in the mean rate of non-core food advertisements from 2006 to 2011. Sydney free-to-air television channels. Televised food advertisements. In 2011 the rate of non-core food advertisements was not significantly different from that in 2006 or 2010 (3·2/h v. 4·1/h and 3·1/h), although there were variations across the intervening years. The rate of fast-food advertising in 2010 was significantly higher than in 2006 (1·8/h v. 1·1/h, P < 0·001), but the same as that in 2011 (1·5/h). The frequency of non-core food advertising on Sydney television has remained essentially unchanged between 2006 and 2011, despite the implementation of two industry self-regulatory pledges. The current study illustrates the value of independent monitoring as a basic requirement of any responsive regulatory approach.

  5. Characterization of shredded television scrap and implications for materials recovery.

    PubMed

    Cui, Jirang; Forssberg, Eric

    2007-01-01

    Characterization of TV scrap was carried out by using a variety of methods, such as chemical analysis, particle size and shape analysis, liberation degree analysis, thermogravimetric analysis, sink-float test, and IR spectrometry. A comparison of TV scrap, personal computer scrap, and printed circuit board scrap shows that the content of non-ferrous metals and precious metals in TV scrap is much lower than that in personal computer scrap or printed circuit board scrap. It is expected that recycling of TV scrap will not be cost-effective by utilizing conventional manual disassembly. The result of particle shape analysis indicates that the non-ferrous metal particles in TV scrap formed as a variety of shapes; it is much more heterogeneous than that of plastics and printed circuit boards. Furthermore, the separability of TV scrap using density-based techniques was evaluated by the sink-float test. The result demonstrates that a high recovery of copper could be obtained by using an effective gravity separation process. Identification of plastics shows that the major plastic in TV scrap is high impact polystyrene. Gravity separation of plastics may encounter some challenges in separation of plastics from TV scrap because of specific density variations.

  6. Characterization of optical-surface-imaging-based spirometry for respiratory surrogating in radiotherapy

    PubMed Central

    Li, Guang; Huang, Hailiang; Chen, Qing; Gaebler, Carl P.; Lin, Tiffany; Yuan, Amy; Rimner, Andreas; Mechalakos, James

    2016-01-01

    Purpose: To provide a comprehensive characterization of a novel respiratory surrogate that uses optical surface imaging (OSI) for accurate tidal volume (TV) measurement, dynamic airflow (TV′) calculation, and quantitative breathing pattern (BP) estimation during free breathing (FB), belly breathing (BB), chest breathing (CB), and breath hold (BH). Methods: Optical surface imaging, which captures all respiration-induced torso surface motion, was applied to measure respiratory TV, TV′, and BP in three common breathing patterns. Eleven healthy volunteers participated in breathing experiments with concurrent OSI-based and conventional spirometric measurements under an institutional review board approved protocol. This OSI-based technique measures dynamic TV from torso volume change (ΔVtorso = TV) in reference to full exhalation and airflow (TV′ = dTV/dt). Volume conservation, excluding exchanging air, was applied for OSI-based measurements under negligible pleural pressure variation in FB, BB, and CB. To demonstrate volume conservation, a constant TV was measured during BH while the chest and belly are moving (“pretended” respiration). To assess the accuracy of OSI-based spirometry, a conventional spirometer was used as the standard for both TV and TV′. Using OSI, BP was measured as BPOSI = ΔVchest/ΔVtorso and BP can be visualized using BPSHI = SHIchest/(SHIchest + SHIbelly), where surface height index (SHI) is defined as the mean vertical distance within a region of interest on the torso surface. A software tool was developed for OSI image processing, volume calculation, and BP visualization, and another tool was implemented for data acquisition using a Bernoulli-type spirometer. Results: The accuracy of the OSI-based spirometry is −21 ± 33 cm3 or −3.5% ± 6.3% averaged from 11 volunteers with 76 ± 28 breathing cycles on average in FB. Breathing variations between two separate acquisitions with approximate 30-min intervals are substantial: −1% ± 34% (ranging from −64% to 40%) in TV, 4% ± 20% (ranging from −50% to 26%) in breathing period (T), and −1% ± 34% (ranging from −49% to 44%) in BP. The airflow accuracy and variation (between two exercises) are −1 ± 54 cm3/s and −5% ± 30%, respectively. The slope of linear regression between OSI–TV and spirometric TV is 0.93 (R2 = 0.95) for FB, 0.96 (R2 = 0.98) for BB, and 0.95 (R2 = 0.95) for CB. The correlation between the two spirometric measurements is 0.98 ± 0.01. BP increases from BB, FB to CB, while TV increases from FB, BB, to CB. Under BH, 4% volume variation (range) on average was observed. Conclusions: The OSI-based technique provides an accurate measurement of tidal volume, airflow rate, and breathing pattern; all affect internal organ motion. This technique can be applied to various breathing patterns, including FB, BB, and CB. Substantial breathing irregularities and irreproducibility were observed and quantified with the OSI-based technique. These breathing parameters are useful to quantify breathing conditions, which could be used for effective tumor motion predictions. PMID:26936719

  7. Evaluation of color mapping algorithms in different color spaces

    NASA Astrophysics Data System (ADS)

    Bronner, Timothée.-Florian; Boitard, Ronan; Pourazad, Mahsa T.; Nasiopoulos, Panos; Ebrahimi, Touradj

    2016-09-01

    The color gamut supported by current commercial displays is only a subset of the full spectrum of colors visible by the human eye. In High-Definition (HD) television technology, the scope of the supported colors covers 35.9% of the full visible gamut. For comparison, Ultra High-Definition (UHD) television, which is currently being deployed on the market, extends this range to 75.8%. However, when reproducing content with a wider color gamut than that of a television, typically UHD content on HD television, some original color information may lie outside the reproduction capabilities of the television. Efficient gamut mapping techniques are required in order to fit the colors of any source content into the gamut of a given display. The goal of gamut mapping is to minimize the distortion, in terms of perceptual quality, when converting video from one color gamut to another. It is assumed that the efficiency of gamut mapping depends on the color space in which it is computed. In this article, we evaluate 14 gamut mapping techniques, 12 combinations of two projection methods across six color spaces as well as R'G'B' Clipping and wrong gamut interpretation. Objective results, using the CIEDE2000 metric, show that the R'G'B' Clipping is slightly outperformed by only one combination of color space and projection method. However, analysis of images shows that R'G'B' Clipping can result in loss of contrast in highly saturated images, greatly impairing the quality of the mapped image.

  8. Adoption and Use of Videocassette Recorders in the Third World.

    ERIC Educational Resources Information Center

    Straubhaar, Joseph; Boyd, Douglas A.

    Videocassette recorder (VCR) acquisition and use in developing nations is largely an individual or household decision, and their rapid diffusion is influenced by several factors: price, and its variations due to government restrictions; income and income distribution; the content of broadcast television; the diversity of entertainment media…

  9. Compressed-sensing-based content-driven hierarchical reconstruction: Theory and application to C-arm cone-beam tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langet, Hélène; Laboratoire des Signaux et Systèmes, CentraleSupélec, Gif-sur-Yvette F-91192; Center for Visual Computing, CentraleSupélec, Châtenay-Malabry F-92295

    2015-09-15

    Purpose: This paper addresses the reconstruction of x-ray cone-beam computed tomography (CBCT) for interventional C-arm systems. Subsampling of CBCT is a significant issue with C-arms due to their slow rotation and to the low frame rate of their flat panel x-ray detectors. The aim of this work is to propose a novel method able to handle the subsampling artifacts generally observed with analytical reconstruction, through a content-driven hierarchical reconstruction based on compressed sensing. Methods: The central idea is to proceed with a hierarchical method where the most salient features (high intensities or gradients) are reconstructed first to reduce the artifactsmore » these features induce. These artifacts are addressed first because their presence contaminates less salient features. Several hierarchical schemes aiming at streak artifacts reduction are introduced for C-arm CBCT: the empirical orthogonal matching pursuit approach with the ℓ{sub 0} pseudonorm for reconstructing sparse vessels; a convex variant using homotopy with the ℓ{sub 1}-norm constraint of compressed sensing, for reconstructing sparse vessels over a nonsparse background; homotopy with total variation (TV); and a novel empirical extension to nonlinear diffusion (NLD). Such principles are implemented with penalized iterative filtered backprojection algorithms. For soft-tissue imaging, the authors compare the use of TV and NLD filters as sparsity constraints, both optimized with the alternating direction method of multipliers, using a threshold for TV and a nonlinear weighting for NLD. Results: The authors show on simulated data that their approach provides fast convergence to good approximations of the solution of the TV-constrained minimization problem introduced by the compressed sensing theory. Using C-arm CBCT clinical data, the authors show that both TV and NLD can deliver improved image quality by reducing streaks. Conclusions: A flexible compressed-sensing-based algorithmic approach is proposed that is able to accommodate for a wide range of constraints. It is successfully applied to C-arm CBCT images that may not be so well approximated by piecewise constant functions.« less

  10. Discontinuity minimization for omnidirectional video projections

    NASA Astrophysics Data System (ADS)

    Alshina, Elena; Zakharchenko, Vladyslav

    2017-09-01

    Advances in display technologies both for head mounted devices and television panels demand resolution increase beyond 4K for source signal in virtual reality video streaming applications. This poses a problem of content delivery trough a bandwidth limited distribution networks. Considering a fact that source signal covers entire surrounding space investigation reviled that compression efficiency may fluctuate 40% in average depending on origin selection at the conversion stage from 3D space to 2D projection. Based on these knowledge the origin selection algorithm for video compression applications has been proposed. Using discontinuity entropy minimization function projection origin rotation may be defined to provide optimal compression results. Outcome of this research may be applied across various video compression solutions for omnidirectional content.

  11. Evaluation of a 15-inch widescreen OLED with sunlight-readable resistive touch panel

    NASA Astrophysics Data System (ADS)

    Hufnagel, Bruce D.; Tchon, Joseph L.; Bahadur, Birendra

    2012-06-01

    A commercially available 15-inch active-matrix organic light-emitting diode (AMOLED) television was modified to include a sunlight-readable resistive touch panel for technical evaluation with regard to a variety of rugged military and aerospace applications. By removing the circular polarizer (CP) from the AMOLED and relying on the touch panel's CP, the authors were able to minimize change in display luminance while adding touch capability and reducing reflectance.

  12. Small diameter, deep bore optical inspection system

    DOEpatents

    Lord, David E.; Petrini, Richard R.; Carter, Gary W.

    1981-01-01

    An improved rod optic system for inspecting small diameter, deep bores. The system consists of a rod optic system utilizing a curved mirror at the end of the rod lens such that the optical path through the system is bent 90.degree. to minimize optical distortion in examining the sides of a curved bore. The system is particularly useful in the examination of small bores for corrosion, and is capable of examining 1/16 inch diameter and up to 4 inch deep drill holes, for example. The positioning of the curved mirror allows simultaneous viewing from shallow and right angle points of observation of the same artifact (such as corrosion) in the bore hole. The improved rod optic system may be used for direct eye sighting, or in combination with a still camera or a low-light television monitor; particularly low-light color television.

  13. "Triangle of safety": anatomic considerations in transvaginal natural orifice surgery.

    PubMed

    Roberts, Kurt; Solomon, Daniel; Bell, Robert; Duffy, Andrew

    2013-08-01

    The introduction of transvaginal (TV) natural orifice transluminal endoscopic surgery (NOTES) brings the loss of traditionally used cutaneous landmarks for safe peritoneal access. This video describes the use of landmarks within the posterior vaginal fornix to define a "triangle of safety" wherein the peritoneal cavity can be accessed while minimizing the risk of injury to surrounding structures. The triangle of safety is best identified in the following way. The cervix and posterior fornix are visualized. Then an imaginary clock located at the base of the cervix is envisioned. The superior two corners of the triangle are represented by the 4 and 8 o'clock positions on this imaginary clock. Sometimes the cervix needs to be grasped and elevated anteriorly so that the inferior apex of the triangle delineated by the center of the rectovaginal fold is better visualized. During hybrid TV NOTES, the rectovaginal pouch of Douglas is visualized from the umbilicus, and the vaginal port can then be safely passed through the center of the triangle. It is important that the vaginal port should be angled upward, aiming toward the umbilicus to avoid injury to the rectum. During pure TV NOTES, the incision is made with electrocautery from the 5 o'clock position to the 7 o'clock position within the triangle. The peritoneum is sharply entered, and the colpotomy is dilated with the surgeons' fingers. The triangle of safety defines a set of landmarks between the base of the cervix and the rectovaginal fold. It allows for a safe TV access for hybrid and pure TV NOTES while minimizing the risk of injury to surrounding structures.

  14. Novel crystal timing calibration method based on total variation

    NASA Astrophysics Data System (ADS)

    Yu, Xingjian; Isobe, Takashi; Watanabe, Mitsuo; Liu, Huafeng

    2016-11-01

    A novel crystal timing calibration method based on total variation (TV), abbreviated as ‘TV merge’, has been developed for a high-resolution positron emission tomography (PET) system. The proposed method was developed for a system with a large number of crystals, it can provide timing calibration at the crystal level. In the proposed method, the timing calibration process was formulated as a linear problem. To robustly optimize the timing resolution, a TV constraint was added to the linear equation. Moreover, to solve the computer memory problem associated with the calculation of the timing calibration factors for systems with a large number of crystals, the merge component was used for obtaining the crystal level timing calibration values. Compared with other conventional methods, the data measured from a standard cylindrical phantom filled with a radioisotope solution was sufficient for performing a high-precision crystal-level timing calibration. In this paper, both simulation and experimental studies were performed to demonstrate the effectiveness and robustness of the TV merge method. We compare the timing resolutions of a 22Na point source, which was located in the field of view (FOV) of the brain PET system, with various calibration techniques. After implementing the TV merge method, the timing resolution improved from 3.34 ns at full width at half maximum (FWHM) to 2.31 ns FWHM.

  15. Low dose CBCT reconstruction via prior contour based total variation (PCTV) regularization: a feasibility study

    NASA Astrophysics Data System (ADS)

    Chen, Yingxuan; Yin, Fang-Fang; Zhang, Yawei; Zhang, You; Ren, Lei

    2018-04-01

    Purpose: compressed sensing reconstruction using total variation (TV) tends to over-smooth the edge information by uniformly penalizing the image gradient. The goal of this study is to develop a novel prior contour based TV (PCTV) method to enhance the edge information in compressed sensing reconstruction for CBCT. Methods: the edge information is extracted from prior planning-CT via edge detection. Prior CT is first registered with on-board CBCT reconstructed with TV method through rigid or deformable registration. The edge contours in prior-CT is then mapped to CBCT and used as the weight map for TV regularization to enhance edge information in CBCT reconstruction. The PCTV method was evaluated using extended-cardiac-torso (XCAT) phantom, physical CatPhan phantom and brain patient data. Results were compared with both TV and edge preserving TV (EPTV) methods which are commonly used for limited projection CBCT reconstruction. Relative error was used to calculate pixel value difference and edge cross correlation was defined as the similarity of edge information between reconstructed images and ground truth in the quantitative evaluation. Results: compared to TV and EPTV, PCTV enhanced the edge information of bone, lung vessels and tumor in XCAT reconstruction and complex bony structures in brain patient CBCT. In XCAT study using 45 half-fan CBCT projections, compared with ground truth, relative errors were 1.5%, 0.7% and 0.3% and edge cross correlations were 0.66, 0.72 and 0.78 for TV, EPTV and PCTV, respectively. PCTV is more robust to the projection number reduction. Edge enhancement was reduced slightly with noisy projections but PCTV was still superior to other methods. PCTV can maintain resolution while reducing the noise in the low mAs CatPhan reconstruction. Low contrast edges were preserved better with PCTV compared with TV and EPTV. Conclusion: PCTV preserved edge information as well as reduced streak artifacts and noise in low dose CBCT reconstruction. PCTV is superior to TV and EPTV methods in edge enhancement, which can potentially improve the localization accuracy in radiation therapy.

  16. A photoacoustic imaging reconstruction method based on directional total variation with adaptive directivity.

    PubMed

    Wang, Jin; Zhang, Chen; Wang, Yuanyuan

    2017-05-30

    In photoacoustic tomography (PAT), total variation (TV) based iteration algorithm is reported to have a good performance in PAT image reconstruction. However, classical TV based algorithm fails to preserve the edges and texture details of the image because it is not sensitive to the direction of the image. Therefore, it is of great significance to develop a new PAT reconstruction algorithm to effectively solve the drawback of TV. In this paper, a directional total variation with adaptive directivity (DDTV) model-based PAT image reconstruction algorithm, which weightedly sums the image gradients based on the spatially varying directivity pattern of the image is proposed to overcome the shortcomings of TV. The orientation field of the image is adaptively estimated through a gradient-based approach. The image gradients are weighted at every pixel based on both its anisotropic direction and another parameter, which evaluates the estimated orientation field reliability. An efficient algorithm is derived to solve the iteration problem associated with DDTV and possessing directivity of the image adaptively updated for each iteration step. Several texture images with various directivity patterns are chosen as the phantoms for the numerical simulations. The 180-, 90- and 30-view circular scans are conducted. Results obtained show that the DDTV-based PAT reconstructed algorithm outperforms the filtered back-projection method (FBP) and TV algorithms in the quality of reconstructed images with the peak signal-to-noise rations (PSNR) exceeding those of TV and FBP by about 10 and 18 dB, respectively, for all cases. The Shepp-Logan phantom is studied with further discussion of multimode scanning, convergence speed, robustness and universality aspects. In-vitro experiments are performed for both the sparse-view circular scanning and linear scanning. The results further prove the effectiveness of the DDTV, which shows better results than that of the TV with sharper image edges and clearer texture details. Both numerical simulation and in vitro experiments confirm that the DDTV provides a significant quality improvement of PAT reconstructed images for various directivity patterns.

  17. Trends in US newspaper and television coverage of tobacco.

    PubMed

    Nelson, David E; Pederson, Linda L; Mowery, Paul; Bailey, Sarah; Sevilimedu, Varadan; London, Joel; Babb, Stephen; Pechacek, Terry

    2015-01-01

    The news media plays an important role in agenda setting and framing of stories about tobacco control. The purpose of this study was to examine newspaper, newswire and television coverage of tobacco issues in the USA over a 7-year period. Analyses of 2004-2010 news media surveillance system data from the US Centers for Disease Control and Prevention's Office on Smoking and Health, based on content analysis and quantitative methods. Information on extent of news coverage, and types of tobacco-related themes, were examined from articles in 10 newspapers and 2 major newswires, as well as transcripts from 6 national television networks. The overall extent of newspaper, newswire and television stories about tobacco, and level of coverage by specific media outlets, varied over time, especially for newspapers. Nevertheless, there was an average of 3 newspaper stories, 4 newswire stories, and 1 television tobacco-related story each day. Television stories were more likely to contain cessation/addiction or health effects/statistics themes and less likely to contain secondhand smoke or policy/regulation themes than newspaper/newswire stories. There was more variation in the choice of tobacco theme among individual newspapers/newswires than television media outlets. News coverage of tobacco in the USA was relatively constant from 2004 to 2010. Audiences were more likely to be exposed to different tobacco themes in newspapers/newswires than on television. Tracking information about tobacco news stories can be used by advocates, programs and others for planning and evaluation, and by researchers for hypothesis generation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Radar Versus Stealth: Passive Radar and the Future of U.S. Military Power

    DTIC Science & Technology

    2009-01-01

    minimizing, if not nul- lifying , the advantages of the defensive.”3 Douhet did not envision the many sur- face-to-air threats that would evolve over the...is emerging, enabled by advances in networked computing and passive radar technology. Because of their potential to counter stealth-based airpower...waveforms include FM and AM radio, television, digital audio/video broadcast, and cellular phone networks .38 Today, passive radar is often configured as a

  19. An adaptive DPCM algorithm for predicting contours in NTSC composite video signals

    NASA Astrophysics Data System (ADS)

    Cox, N. R.

    An adaptive DPCM algorithm is proposed for encoding digitized National Television Systems Committee (NTSC) color video signals. This algorithm essentially predicts picture contours in the composite signal without resorting to component separation. The contour parameters (slope thresholds) are optimized using four 'typical' television frames that have been sampled at three times the color subcarrier frequency. Three variations of the basic predictor are simulated and compared quantitatively with three non-adaptive predictors of similar complexity. By incorporating a dual-word-length coder and buffer memory, high quality color pictures can be encoded at 4.0 bits/pel or 42.95 Mbit/s. The effect of channel error propagation is also investigated.

  20. Low dose CT reconstruction via L1 norm dictionary learning using alternating minimization algorithm and balancing principle.

    PubMed

    Wu, Junfeng; Dai, Fang; Hu, Gang; Mou, Xuanqin

    2018-04-18

    Excessive radiation exposure in computed tomography (CT) scans increases the chance of developing cancer and has become a major clinical concern. Recently, statistical iterative reconstruction (SIR) with l0-norm dictionary learning regularization has been developed to reconstruct CT images from the low dose and few-view dataset in order to reduce radiation dose. Nonetheless, the sparse regularization term adopted in this approach is l0-norm, which cannot guarantee the global convergence of the proposed algorithm. To address this problem, in this study we introduced the l1-norm dictionary learning penalty into SIR framework for low dose CT image reconstruction, and developed an alternating minimization algorithm to minimize the associated objective function, which transforms CT image reconstruction problem into a sparse coding subproblem and an image updating subproblem. During the image updating process, an efficient model function approach based on balancing principle is applied to choose the regularization parameters. The proposed alternating minimization algorithm was evaluated first using real projection data of a sheep lung CT perfusion and then using numerical simulation based on sheep lung CT image and chest image. Both visual assessment and quantitative comparison using terms of root mean square error (RMSE) and structural similarity (SSIM) index demonstrated that the new image reconstruction algorithm yielded similar performance with l0-norm dictionary learning penalty and outperformed the conventional filtered backprojection (FBP) and total variation (TV) minimization algorithms.

  1. Iterative image reconstruction for multienergy computed tomography via structure tensor total variation regularization

    NASA Astrophysics Data System (ADS)

    Zeng, Dong; Bian, Zhaoying; Gong, Changfei; Huang, Jing; He, Ji; Zhang, Hua; Lu, Lijun; Feng, Qianjin; Liang, Zhengrong; Ma, Jianhua

    2016-03-01

    Multienergy computed tomography (MECT) has the potential to simultaneously offer multiple sets of energy- selective data belonging to specific energy windows. However, because sufficient photon counts are not available in the specific energy windows compared with that in the whole energy window, the MECT images reconstructed by the analytical approach often suffer from poor signal-to-noise (SNR) and strong streak artifacts. To eliminate this drawback, in this work we present a penalized weighted least-squares (PWLS) scheme by incorporating the new concept of structure tensor total variation (STV) regularization to improve the MECT images quality from low-milliampere-seconds (low-mAs) data acquisitions. Henceforth the present scheme is referred to as `PWLS- STV' for simplicity. Specifically, the STV regularization is derived by penalizing the eigenvalues of the structure tensor of every point in the MECT images. Thus it can provide more robust measures of image variation, which can eliminate the patchy artifacts often observed in total variation regularization. Subsequently, an alternating optimization algorithm was adopted to minimize the objective function. Experiments with a digital XCAT phantom clearly demonstrate that the present PWLS-STV algorithm can achieve more gains than the existing TV-based algorithms and the conventional filtered backpeojection (FBP) algorithm in terms of noise-induced artifacts suppression, resolution preservation, and material decomposition assessment.

  2. Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Hanming; Wang, Linyuan; Li, Lei

    2016-06-15

    Purpose: Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However, conventional iterative reconstruction methods easily introduce new artifacts around metal implants because of incomplete data reconstruction and inconsistencies in practical data acquisition. Hence, this work aims at developing a method to suppress newly introduced artifacts and improve the image quality around metal implants for the iterative MAR scheme. Methods: The proposed method consists of twomore » steps based on the general iterative MAR framework. An uncorrected image is initially reconstructed, and the corresponding metal trace is obtained. The iterative reconstruction method is then used to reconstruct images from the unaffected sinogram. In the reconstruction step of this work, an iterative strategy utilizing unmatched projector/backprojector pairs is used. A ramp filter is introduced into the back-projection procedure to restrain the inconsistency components in low frequencies and generate more reliable images of the regions around metals. Furthermore, a constrained total variation (TV) minimization model is also incorporated to enhance efficiency. The proposed strategy is implemented based on an iterative FBP and an alternating direction minimization (ADM) scheme, respectively. The developed algorithms are referred to as “iFBP-TV” and “TV-FADM,” respectively. Two projection-completion-based MAR methods and three iterative MAR methods are performed simultaneously for comparison. Results: The proposed method performs reasonably on both simulation and real CT-scanned datasets. This approach could reduce streak metal artifacts effectively and avoid the mentioned effects in the vicinity of the metals. The improvements are evaluated by inspecting regions of interest and by comparing the root-mean-square errors, normalized mean absolute distance, and universal quality index metrics of the images. Both iFBP-TV and TV-FADM methods outperform other counterparts in all cases. Unlike the conventional iterative methods, the proposed strategy utilizing unmatched projector/backprojector pairs shows excellent performance in detail preservation and prevention of the introduction of new artifacts. Conclusions: Qualitative and quantitative evaluations of experimental results indicate that the developed method outperforms classical MAR algorithms in suppressing streak artifacts and preserving the edge structural information of the object. In particular, structures lying close to metals can be gradually recovered because of the reduction of artifacts caused by inconsistency effects.« less

  3. A Model of Regularization Parameter Determination in Low-Dose X-Ray CT Reconstruction Based on Dictionary Learning

    PubMed Central

    Zhang, Cheng; Zhang, Tao; Li, Ming; Lu, Yanfei; You, Jiali; Guan, Yihui

    2015-01-01

    In recent years, X-ray computed tomography (CT) is becoming widely used to reveal patient's anatomical information. However, the side effect of radiation, relating to genetic or cancerous diseases, has caused great public concern. The problem is how to minimize radiation dose significantly while maintaining image quality. As a practical application of compressed sensing theory, one category of methods takes total variation (TV) minimization as the sparse constraint, which makes it possible and effective to get a reconstruction image of high quality in the undersampling situation. On the other hand, a preliminary attempt of low-dose CT reconstruction based on dictionary learning seems to be another effective choice. But some critical parameters, such as the regularization parameter, cannot be determined by detecting datasets. In this paper, we propose a reweighted objective function that contributes to a numerical calculation model of the regularization parameter. A number of experiments demonstrate that this strategy performs well with better reconstruction images and saving of a large amount of time. PMID:26550024

  4. Small diameter, deep bore optical inspection system

    DOEpatents

    Lord, D.E.; Petrini, R.R.; Carter, G.W.

    An improved rod optic system for inspecting small diameter, deep bores is described. The system consists of a rod optic system utilizing a curved mirror at the end of the rod lens such that the optical path through the system is bent 90/sup 0/ to minimize optical distortion in examing the sides of a curved bore. The system is particularly useful in the examination of small bores for corrosion, and is capable if examing 1/16 inch diameter and up to 4-inch deep drill holes, for example. The positioning of the curved mirror allows simultaneous viewing from shallow and righ angle points of observation of the same artifact (such as corrosion) in the bore hole. The improved rod optic system may be used for direct eye sighting, or in combination with a still camera or a low-light television monitor; particularly low-light color television.

  5. Messages of distinction: the HIV/AIDS media campaign in Thailand.

    PubMed

    Lyttleton, C

    1996-03-01

    In predominantly rural Thailand, television is a primary source of HIV/AIDS knowledge. Since 1990, HIV/AIDS warning messages have been aired regularly and repeatedly on television as part of the national strategy to minimize transmission of HIV. The education and prevention messages chosen do more than suggest measures to avoid infection. Within a logic of risk, these messages also define characteristics of people who are signified as threatening agents of infection. In Thailand, prostitutes and drug users are portrayed as the feared Other. Because commercial sex is so widespread, the demarcation of prostitutes as a high risk group signals a diffuse threat not easily subject to conceptual distancing. It is the pervasive and often fear-based associations born of the media material that, in large part, establish the basis for emergent practice when thoughts or actions are triggered by consideration of HIV/AIDS.

  6. A Variational Approach to the Denoising of Images Based on Different Variants of the TV-Regularization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bildhauer, Michael, E-mail: bibi@math.uni-sb.de; Fuchs, Martin, E-mail: fuchs@math.uni-sb.de

    2012-12-15

    We discuss several variants of the TV-regularization model used in image recovery. The proposed alternatives are either of nearly linear growth or even of linear growth, but with some weak ellipticity properties. The main feature of the paper is the investigation of the analytic properties of the corresponding solutions.

  7. SU-G-BRA-11: Tumor Tracking in An Iterative Volume of Interest Based 4D CBCT Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, R; Pan, T; Ahmad, M

    2016-06-15

    Purpose: 4D CBCT can allow evaluation of tumor motion immediately prior to radiation therapy, but suffers from heavy artifacts that limit its ability to track tumors. Various iterative and compressed sensing reconstructions have been proposed to reduce these artifacts, but are costly time-wise and can degrade the image quality of bony anatomy for alignment with regularization. We have previously proposed an iterative volume of interest (I4D VOI) method which minimizes reconstruction time and maintains image quality of bony anatomy by focusing a 4D reconstruction within a VOI. The purpose of this study is to test the tumor tracking accuracy ofmore » this method compared to existing methods. Methods: Long scan (8–10 mins) CBCT data with corresponding RPM data was collected for 12 lung cancer patients. The full data set was sorted into 8 phases and reconstructed using FDK cone beam reconstruction to serve as a gold standard. The data was reduced in way that maintains a normal breathing pattern and used to reconstruct 4D images using FDK, low and high regularization TV minimization (λ=2,10), and the proposed I4D VOI method with PTVs used for the VOI. Tumor trajectories were found using rigid registration within the VOI for each reconstruction and compared to the gold standard. Results: The root mean square error (RMSE) values were 2.70mm for FDK, 2.50mm for low regularization TV, 1.48mm for high regularization TV, and 2.34mm for I4D VOI. Streak artifacts in I4D VOI were reduced compared to FDK and images were less blurred than TV reconstructed images. Conclusion: I4D VOI performed at least as well as existing methods in tumor tracking, with the exception of high regularization TV minimization. These results along with the reconstruction time and outside VOI image quality advantages suggest I4D VOI to be an improvement over existing methods. Funding support provided by CPRIT grant RP110562-P2-01.« less

  8. Low-mAs X-ray CT image reconstruction by adaptive-weighted TV-constrained penalized re-weighted least-squares

    PubMed Central

    Liu, Yan; Ma, Jianhua; Zhang, Hao; Wang, Jing; Liang, Zhengrong

    2014-01-01

    Background The negative effects of X-ray exposure, such as inducing genetic and cancerous diseases, has arisen more attentions. Objective This paper aims to investigate a penalized re-weighted least-square (PRWLS) strategy for low-mAs X-ray computed tomography image reconstruction by incorporating an adaptive weighted total variation (AwTV) penalty term and a noise variance model of projection data. Methods An AwTV penalty is introduced in the objective function by considering both piecewise constant property and local nearby intensity similarity of the desired image. Furthermore, the weight of data fidelity term in the objective function is determined by our recent study on modeling variance estimation of projection data in the presence of electronic background noise. Results The presented AwTV-PRWLS algorithm can achieve the highest full-width-at-half-maximum (FWHM) measurement, for data conditions of (1) full-view 10mA acquisition and (2) sparse-view 80mA acquisition. In comparison between the AwTV/TV-PRWLS strategies and the previous reported AwTV/TV-projection onto convex sets (AwTV/TV-POCS) approaches, the former can gain in terms of FWHM for data condition (1), but cannot gain for the data condition (2). Conclusions In the case of full-view 10mA projection data, the presented AwTV-PRWLS shows potential improvement. However, in the case of sparse-view 80mA projection data, the AwTV/TV-POCS shows advantage over the PRWLS strategies. PMID:25080113

  9. Parameter selection in limited data cone-beam CT reconstruction using edge-preserving total variation algorithms

    NASA Astrophysics Data System (ADS)

    Lohvithee, Manasavee; Biguri, Ander; Soleimani, Manuchehr

    2017-12-01

    There are a number of powerful total variation (TV) regularization methods that have great promise in limited data cone-beam CT reconstruction with an enhancement of image quality. These promising TV methods require careful selection of the image reconstruction parameters, for which there are no well-established criteria. This paper presents a comprehensive evaluation of parameter selection in a number of major TV-based reconstruction algorithms. An appropriate way of selecting the values for each individual parameter has been suggested. Finally, a new adaptive-weighted projection-controlled steepest descent (AwPCSD) algorithm is presented, which implements the edge-preserving function for CBCT reconstruction with limited data. The proposed algorithm shows significant robustness compared to three other existing algorithms: ASD-POCS, AwASD-POCS and PCSD. The proposed AwPCSD algorithm is able to preserve the edges of the reconstructed images better with fewer sensitive parameters to tune.

  10. Associations of television viewing time with adults' well-being and vitality.

    PubMed

    Dempsey, Paddy C; Howard, Bethany J; Lynch, Brigid M; Owen, Neville; Dunstan, David W

    2014-12-01

    Television (TV) viewing, a common leisure-time sedentary behaviour, is associated adversely with cardio-metabolic health, fatigue, depression and mental health. However, associations of TV viewing time with health-related quality of life attributes are less well understood. We examined associations of TV viewing time with physical well-being, mental well-being and vitality in a large population-based sample of Australian adults. The study sample comprised 4,483 men and 5,424 women (mean age 51±14years) from the Australian Diabetes, Obesity and Lifestyle study (1999-2000). Multiple linear regressions examined associations of TV viewing time (h/day) with the SF-36v1 physical and mental health component summary scores and the vitality sub-score, adjusting for leisure-time physical activity and waist circumference. Each 1-h/day increment in TV viewing time was associated with lower physical (-0.56 [95% CI: -0.77, -0.34]) and mental (-0.41 [-0.70, -0.12]) component summary scores and vitality (-0.51 [-0.81, -0.21]). Associations remained significant after adjustment for leisure-time physical activity and waist circumference. There was a gender interaction for the association of TV viewing time with vitality (significant in men only). TV viewing time is associated adversely with physical well-being, mental well-being and vitality. Further studies are required to better understand potential causal relationships and variations by gender and leisure-time physical activity. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. The remote, the mouse, and the no. 2 pencil: the household media environment and academic achievement among third grade students.

    PubMed

    Borzekowski, Dina L G; Robinson, Thomas N

    2005-07-01

    Media can influence aspects of a child's physical, social, and cognitive development; however, the associations between a child's household media environment, media use, and academic achievement have yet to be determined. To examine relationships among a child's household media environment, media use, and academic achievement. During a single academic year, data were collected through classroom surveys and telephone interviews from an ethnically diverse sample of third grade students and their parents from 6 northern California public elementary schools. The majority of our analyses derive from spring 2000 data, including academic achievement assessed through the mathematics, reading, and language arts sections of the Stanford Achievement Test. We fit linear regression models to determine the associations between variations in household media and performance on the standardized tests, adjusting for demographic and media use variables. The household media environment is significantly associated with students' performance on the standardized tests. It was found that having a bedroom television set was significantly and negatively associated with students' test scores, while home computer access and use were positively associated with the scores. Regression models significantly predicted up to 24% of the variation in the scores. Absence of a bedroom television combined with access to a home computer was consistently associated with the highest standardized test scores. This study adds to the growing literature reporting that having a bedroom television set may be detrimental to young elementary school children. It also suggests that having and using a home computer may be associated with better academic achievement.

  12. Pre- and Postdiagnosis Physical Activity, Television Viewing, and Mortality Among Patients With Colorectal Cancer in the National Institutes of Health–AARP Diet and Health Study

    PubMed Central

    Arem, Hannah; Pfeiffer, Ruth M.; Engels, Eric A.; Alfano, Catherine M.; Hollenbeck, Albert; Park, Yikyung; Matthews, Charles E.

    2015-01-01

    Purpose Physical inactivity has been associated with higher mortality risk among survivors of colorectal cancer (CRC), but the independent effects of pre- versus postdiagnosis activity are unclear, and the association between watching television (TV) and mortality in survivors of CRC is previously undefined. Methods We analyzed the associations between prediagnosis (n = 3,797) and postdiagnosis (n = 1,759) leisure time physical activity (LTPA) and TV watching and overall and disease-specific mortality among patients with CRC. We used Cox proportional hazards regression to estimate hazard ratios (HRs) and 95% CIs, adjusting for known mortality risk factors. Results Comparing survivors of CRC reporting more than 7 hours per week (h/wk) of prediagnosis LTPA with those reporting no LTPA, we found a 20% lower risk of all-cause mortality (HR, 0.80; 95% CI, 0.68 to 0.95; P for trend = .021). Postdiagnosis LTPA of ≥ 7 h/wk, compared with none, was associated with a 31% lower all-cause mortality risk (HR, 0.69; 95% CI, 0.49 to 0.98; P for trend = .006), independent of prediagnosis activity. Compared with 0 to 2 TV hours per day (h/d) before diagnosis, those reporting ≥ 5 h/d of TV before diagnosis had a 22% increased all-cause mortality risk (HR, 1.22; 95% CI, 1.06 to 1.41; P trend = .002), and more postdiagnosis TV watching was associated with a nonsignificant 25% increase in all-cause mortality risk (HR, 1.25; 95% CI, 0.93 to 1.67; P for trend = .126). Conclusion LTPA was inversely associated with all-cause mortality, whereas more TV watching was associated with increased mortality risk. For both LTPA and TV watching, postdiagnosis measures independently explained the association with mortality. Clinicians should promote both minimizing TV time and increasing physical activity for longevity among survivors of CRC, regardless of previous behaviors. PMID:25488967

  13. Pre- and postdiagnosis physical activity, television viewing, and mortality among patients with colorectal cancer in the National Institutes of Health-AARP Diet and Health Study.

    PubMed

    Arem, Hannah; Pfeiffer, Ruth M; Engels, Eric A; Alfano, Catherine M; Hollenbeck, Albert; Park, Yikyung; Matthews, Charles E

    2015-01-10

    Physical inactivity has been associated with higher mortality risk among survivors of colorectal cancer (CRC), but the independent effects of pre- versus postdiagnosis activity are unclear, and the association between watching television (TV) and mortality in survivors of CRC is previously undefined. We analyzed the associations between prediagnosis (n = 3,797) and postdiagnosis (n = 1,759) leisure time physical activity (LTPA) and TV watching and overall and disease-specific mortality among patients with CRC. We used Cox proportional hazards regression to estimate hazard ratios (HRs) and 95% CIs, adjusting for known mortality risk factors. Comparing survivors of CRC reporting more than 7 hours per week (h/wk) of prediagnosis LTPA with those reporting no LTPA, we found a 20% lower risk of all-cause mortality (HR, 0.80; 95% CI, 0.68 to 0.95; P for trend = .021). Postdiagnosis LTPA of ≥ 7 h/wk, compared with none, was associated with a 31% lower all-cause mortality risk (HR, 0.69; 95% CI, 0.49 to 0.98; P for trend = .006), independent of prediagnosis activity. Compared with 0 to 2 TV hours per day (h/d) before diagnosis, those reporting ≥ 5 h/d of TV before diagnosis had a 22% increased all-cause mortality risk (HR, 1.22; 95% CI, 1.06 to 1.41; P trend = .002), and more postdiagnosis TV watching was associated with a nonsignificant 25% increase in all-cause mortality risk (HR, 1.25; 95% CI, 0.93 to 1.67; P for trend = .126). LTPA was inversely associated with all-cause mortality, whereas more TV watching was associated with increased mortality risk. For both LTPA and TV watching, postdiagnosis measures independently explained the association with mortality. Clinicians should promote both minimizing TV time and increasing physical activity for longevity among survivors of CRC, regardless of previous behaviors. © 2014 by American Society of Clinical Oncology.

  14. Body-Image Evaluation and Body-Image Investment among Adolescents: A Test of Sociocultural and Social Comparison Theories

    ERIC Educational Resources Information Center

    Morrison, Todd G.; Kalin, Rudolf; Morrison, Melanie A.

    2004-01-01

    Sociocultural theory and social comparison theory were used to account for variations in body-image evaluation and body-image investment among male and female adolescents (N = 1,543). Exposure to magazines and television programs containing idealistic body imagery as well as frequency of self-comparison to universalistic targets (e.g., fashion…

  15. Research on compressive sensing reconstruction algorithm based on total variation model

    NASA Astrophysics Data System (ADS)

    Gao, Yu-xuan; Sun, Huayan; Zhang, Tinghua; Du, Lin

    2017-12-01

    Compressed sensing for breakthrough Nyquist sampling theorem provides a strong theoretical , making compressive sampling for image signals be carried out simultaneously. In traditional imaging procedures using compressed sensing theory, not only can it reduces the storage space, but also can reduce the demand for detector resolution greatly. Using the sparsity of image signal, by solving the mathematical model of inverse reconfiguration, realize the super-resolution imaging. Reconstruction algorithm is the most critical part of compression perception, to a large extent determine the accuracy of the reconstruction of the image.The reconstruction algorithm based on the total variation (TV) model is more suitable for the compression reconstruction of the two-dimensional image, and the better edge information can be obtained. In order to verify the performance of the algorithm, Simulation Analysis the reconstruction result in different coding mode of the reconstruction algorithm based on the TV reconstruction algorithm. The reconstruction effect of the reconfigurable algorithm based on TV based on the different coding methods is analyzed to verify the stability of the algorithm. This paper compares and analyzes the typical reconstruction algorithm in the same coding mode. On the basis of the minimum total variation algorithm, the Augmented Lagrangian function term is added and the optimal value is solved by the alternating direction method.Experimental results show that the reconstruction algorithm is compared with the traditional classical algorithm based on TV has great advantages, under the low measurement rate can be quickly and accurately recovers target image.

  16. Parallel algorithm of real-time infrared image restoration based on total variation theory

    NASA Astrophysics Data System (ADS)

    Zhu, Ran; Li, Miao; Long, Yunli; Zeng, Yaoyuan; An, Wei

    2015-10-01

    Image restoration is a necessary preprocessing step for infrared remote sensing applications. Traditional methods allow us to remove the noise but penalize too much the gradients corresponding to edges. Image restoration techniques based on variational approaches can solve this over-smoothing problem for the merits of their well-defined mathematical modeling of the restore procedure. The total variation (TV) of infrared image is introduced as a L1 regularization term added to the objective energy functional. It converts the restoration process to an optimization problem of functional involving a fidelity term to the image data plus a regularization term. Infrared image restoration technology with TV-L1 model exploits the remote sensing data obtained sufficiently and preserves information at edges caused by clouds. Numerical implementation algorithm is presented in detail. Analysis indicates that the structure of this algorithm can be easily implemented in parallelization. Therefore a parallel implementation of the TV-L1 filter based on multicore architecture with shared memory is proposed for infrared real-time remote sensing systems. Massive computation of image data is performed in parallel by cooperating threads running simultaneously on multiple cores. Several groups of synthetic infrared image data are used to validate the feasibility and effectiveness of the proposed parallel algorithm. Quantitative analysis of measuring the restored image quality compared to input image is presented. Experiment results show that the TV-L1 filter can restore the varying background image reasonably, and that its performance can achieve the requirement of real-time image processing.

  17. A systematic method for using 3D echocardiography to evaluate tricuspid valve insufficiency in hypoplastic left heart syndrome.

    PubMed

    Mart, Christopher Robin; Eckhauser, Aaron Wesley; Murri, Michael; Su, Jason Thomas

    2014-09-01

    With surgical palliation of hypoplastic left heart syndrome (HLHS), the tricuspid valve (TV) becomes the systemic atrioventricular valve and moderate/severe TV insufficiency (TVI), an adverse risk factor for survival to Fontan, has been reported in up to 35% of patients prior to stage I palliation. Precise echocardiographic identification of the mechanism of TVI cannot be determined by two-dimensional echocardiography. Three-dimensional echocardiography (3DE) can provide significant insight into the mechanisms of TVI. It is the intent of this report to propose a systematic method on how to evaluate and display 3DE images of the TV in HLHS which has not been done previously. TV anatomy, function, and the known mechanisms of insufficiency are reviewed. We defined three regions of the TV (anterior, posterior, septal) that can help define valve "leaflets" that incorporates the many variations of TV anatomy. To determine how the surgeon views the TV, a picture of a pathologic specimen of the TV was placed on a computer screen and rotated until it was oriented as it appears during surgery, the "surgeons view." We have proposed a systematic method for evaluating and displaying the TV using 3DE which can provide significant insight into the mechanisms causing TVI in HLHS. This has the potential to improve both the surgical approach to repairing the valve and, ultimately, patient outcomes.

  18. A systematic method for using 3D echocardiography to evaluate tricuspid valve insufficiency in hypoplastic left heart syndrome

    PubMed Central

    Mart, Christopher Robin; Eckhauser, Aaron Wesley; Murri, Michael; Su, Jason Thomas

    2014-01-01

    With surgical palliation of hypoplastic left heart syndrome (HLHS), the tricuspid valve (TV) becomes the systemic atrioventricular valve and moderate/severe TV insufficiency (TVI), an adverse risk factor for survival to Fontan, has been reported in up to 35% of patients prior to stage I palliation. Precise echocardiographic identification of the mechanism of TVI cannot be determined by two-dimensional echocardiography. Three-dimensional echocardiography (3DE) can provide significant insight into the mechanisms of TVI. It is the intent of this report to propose a systematic method on how to evaluate and display 3DE images of the TV in HLHS which has not been done previously. TV anatomy, function, and the known mechanisms of insufficiency are reviewed. We defined three regions of the TV (anterior, posterior, septal) that can help define valve “leaflets” that incorporates the many variations of TV anatomy. To determine how the surgeon views the TV, a picture of a pathologic specimen of the TV was placed on a computer screen and rotated until it was oriented as it appears during surgery, the “surgeons view.” We have proposed a systematic method for evaluating and displaying the TV using 3DE which can provide significant insight into the mechanisms causing TVI in HLHS. This has the potential to improve both the surgical approach to repairing the valve and, ultimately, patient outcomes. PMID:25298694

  19. Morphological Variations in the Transverse Venous Sinus Anatomy of Dogs and its Relationship to Skull Landmarks.

    PubMed

    Carreira, L Miguel; Ferreira, A

    2016-08-01

    We characterized the anatomical morphology of the transverse venous sinus (TVS) of 69 canine adult cadavers belonging to three groups: brachycephalic (B), dolichocephalic (D) and mesaticephalic (M). In addition, we outlined its path over the skull using five classic human craniometric points (CPs): the asterion (ast), the bregma (b), the glabella (g), the stephanion (st) and the pterion (pt). The study aimed to establish anatomical differences in the TVS between groups and in the relationship between the TVS and skull. We found that TVS anatomy and its relationships to skull landmarks vary markedly between the groups, with similar anatomical arrangements in B and M. The TVS length can be ranked as M < B < D (with D being the biggest), whereas the width can be ranked as M < D < B (with B being the widest) with the right side being smaller than the left. In the B and M groups, the TVS assumes a craniocaudal trajectory that is closer to the lateral skull wall than in D, where the TVS presents a caudocranial direction. By documenting the morphological characteristics of the TVS, we can create a set of anatomical references allowing construction of a basic framework to greatly decrease the probability of TVS injury during neuronavigation procedures when supported by a good knowledge of the skull, brain anatomies and their relationships. © 2015 Blackwell Verlag GmbH.

  20. A content analysis of children's television advertising: focus on food and oral health.

    PubMed

    Morgan, Maria; Fairchild, Ruth; Phillips, Andrea; Stewart, Kate; Hunter, Lindsay

    2009-06-01

    To analyse the nature and content of advertising during children's popular television viewing times with the specific aims of (i) identifying the proportion of advertising time devoted to confectionery and potentially cariogenic products (those which readily give rise to dental caries, more commonly known as tooth decay); and (ii) determining whether there is a variation in the advertisement of confectionery and other high-sugar products within children's school holiday time v. outside holiday time.MethodIn five separate one-week periods, the output of the four most popular British children's commercial television channels was video-recorded during the most popular viewing times for children. In total, 503 h of television were recorded and analysed. Analysis of the recordings revealed that 16.4 % of advertising time was devoted to food products; 6.3 % of all advertising time was devoted to potentially cariogenic products. Sugared cereals were the most commonly advertised high-sugar product, followed by sweetened dairy products and confectionery (chi2 = 6524.8, df = 4, P < 0.001). The advertisement of confectionery and high-sugar foods appeared to be influenced by school holidays. Health-care professionals should be aware of the shift away from the advertisement of confectionery towards the promotion of foods that might be considered healthier but contain large amounts of hidden sugar.

  1. Mass Communication: Abstracts of Doctoral Dissertations Published in "Dissertation Abstracts International," January through June 1981 (Vol. 41 Nos. 7 through 12).

    ERIC Educational Resources Information Center

    ERIC Clearinghouse on Reading and Communication Skills, Urbana, IL.

    This collection of abstracts is part of a continuing series providing information on recent doctoral dissertations. The 47 titles deal with a variety of topics, including the following: (1) the effect of source variation upon children's reactions to television commercials; (2) covert observation as a means of measuring the affective states of…

  2. Battle for Ulster. A Study of Internal Security

    DTIC Science & Technology

    1987-06-01

    More than twenty-three nations sent television crews, with American networks alone assigning sixteen. Over 400 journalists -were present. It=was, for...Independence. Another settlement option is in- dependence for Northern Ireland. This initiative, de- signed to outflank loyalists and- republicans mired in...One such variation is the new Anglo-Irish accord, signed in November -1985, which is perhaps the most important political initiative in the province

  3. Water quality studies of TV station reservoir at Davangere City, Karnataka (India).

    PubMed

    Begum, Nafeesa; Purushothama, R; Narayana, J; Kumar, K P Ravindra

    2006-10-01

    Studies were carried out to assess the water quality of TV station reservoir at Davangere City, Karnataka (India). The study revealed that there were variations in physico-chemical concentrations during the rainy season. Except turbidity, all the other physico-chemical characteristics were found within the permissible limits. The results were compared with the standards given by ISI for water quality.

  4. Television watching and risk of colorectal adenoma

    PubMed Central

    Cao, Y; Keum, N N; Chan, A T; Fuchs, C S; Wu, K; Giovannucci, E L

    2015-01-01

    Background: Prolonged TV watching, a major sedentary behaviour, is associated with increased risk of obesity and diabetes and may involve in colorectal carcinogenesis. Methods: We conducted a cross-sectional analysis among 31 065 men with ⩾1 endoscopy in the Health Professionals Follow-up Study (1988–2008) to evaluate sitting while watching TV and its joint influence with leisure-time physical activity on risk of colorectal adenoma. Logistic regression was used to calculate odds ratios (ORs) and 95% confidence intervals (CIs). Results: Prolonged sitting while watching TV was significantly associated with increased risk of colorectal adenoma (n=4280), and adjusting for physical activity or a potential mediator body mass index did not change the estimates. The ORs (95% CIs) across categories of TV watching (0–6, 7–13, 14–20, and 21+ h per week) were 1.00 (referent), 1.09 (1.01–1.17), 1.16 (1.06–1.27), and 1.10 (0.97–1.25) (OR per 14-h per week increment=1.11; 95% CI: 1.04–1.18; Ptrend=0.001). Compared with the least sedentary (0–6 h per week of TV) and most physically active (highest quintile) men, the most sedentary (14+ h per week) and least active (lowest quintile) men had a significant increased risk of adenoma (OR=1.25; 95% CI: 1.05–1.49), particularly for high-risk adenoma. Conclusions: Prolonged TV viewing is associated with modest increased risk of colorectal adenoma independent of leisure-time physical activity and minimally mediated by obesity. PMID:25590667

  5. A mixed-order nonlinear diffusion compressed sensing MR image reconstruction.

    PubMed

    Joy, Ajin; Paul, Joseph Suresh

    2018-03-07

    Avoid formation of staircase artifacts in nonlinear diffusion-based MR image reconstruction without compromising computational speed. Whereas second-order diffusion encourages the evolution of pixel neighborhood with uniform intensities, fourth-order diffusion considers smooth region to be not necessarily a uniform intensity region but also a planar region. Therefore, a controlled application of fourth-order diffusivity function is used to encourage second-order diffusion to reconstruct the smooth regions of the image as a plane rather than a group of blocks, while not being strong enough to introduce the undesirable speckle effect. Proposed method is compared with second- and fourth-order nonlinear diffusion reconstruction, total variation (TV), total generalized variation, and higher degree TV using in vivo data sets for different undersampling levels with application to dictionary learning-based reconstruction. It is observed that the proposed technique preserves sharp boundaries in the image while preventing the formation of staircase artifacts in the regions of smoothly varying pixel intensities. It also shows reduced error measures compared with second-order nonlinear diffusion reconstruction or TV and converges faster than TV-based methods. Because nonlinear diffusion is known to be an effective alternative to TV for edge-preserving reconstruction, the crucial aspect of staircase artifact removal is addressed. Reconstruction is found to be stable for the experimentally determined range of fourth-order regularization parameter, and therefore not does not introduce a parameter search. Hence, the computational simplicity of second-order diffusion is retained. © 2018 International Society for Magnetic Resonance in Medicine.

  6. Selection of regularization parameter in total variation image restoration.

    PubMed

    Liao, Haiyong; Li, Fang; Ng, Michael K

    2009-11-01

    We consider and study total variation (TV) image restoration. In the literature there are several regularization parameter selection methods for Tikhonov regularization problems (e.g., the discrepancy principle and the generalized cross-validation method). However, to our knowledge, these selection methods have not been applied to TV regularization problems. The main aim of this paper is to develop a fast TV image restoration method with an automatic selection of the regularization parameter scheme to restore blurred and noisy images. The method exploits the generalized cross-validation (GCV) technique to determine inexpensively how much regularization to use in each restoration step. By updating the regularization parameter in each iteration, the restored image can be obtained. Our experimental results for testing different kinds of noise show that the visual quality and SNRs of images restored by the proposed method is promising. We also demonstrate that the method is efficient, as it can restore images of size 256 x 256 in approximately 20 s in the MATLAB computing environment.

  7. Chino del tomate virus:Relationships to Other Begomoviruses and Identification of A-Component Variants that Affect Symptom Expression.

    PubMed

    Brown, J K; Ostrow, K M; Idris, A M; Stenger, D C

    2000-05-01

    Phylogenetic and distance analyses place Chino del tomate virus (CdTV) in the New World clade of begomoviruses and indicate that CdTV and Tomato leaf crumple virus (TLCrV) are closely related strains of the same virus. One cloned CdTV A component (pCdTV-H6), when inoculated to tomato with the B component (pCdTV-B52), produced mild symptoms and low DNA titers. Another cloned CdTV A component (pCdTV-H8), when coinoculated to tomato with the B component, produced moderate leaf curling and veinal chlorosis similar to that of TLCrV. Coinoculation of both CdTV A components and the B component to tomato produced wild-type chino del tomate (CdT) disease symptoms consisting of severe leaf curling, veinal and interveinal chlorosis, and stunting. The two CdTV A components were nearly identical, except at nucleotide positions 1,722 and 2,324. The polymorphism at nucleotide 1,722 resulted in a change at Rep amino acid 261. The second polymorphism at nucleotide 2,324 resulted in changes at Rep amino acid 60 and AC4 amino acid 10. Two chimeric A components constructed by reciprocal exchange of a fragment bearing the polymorphic site at nucleotide 1,722 were evaluated for symptom phenotype. One chimeric A component (pCdTV-H86) produced wild-type CdT symptoms when coinoculated to tomato with the B component. The reciprocal chimeric A component (pCdTV-H68), when coin-oculated to tomato with the B component, also produced severe leaf curling, veinal chlorosis, and stunting. However, pCdTV-H68 induced less obvious interveinal chlorosis than wild-type or pCdTV-H86. Examination of A component genotypes recovered from tomato coinoculated with pCdTV-H6 and pCdTV-H8 indicated that recombination occurred to produce a genotype identical to pCdTV-H86. These results indicate that subtle genotypic variation has significant effects on symptom expression and may explain phenotypic differences observed among isolates and cloned DNAs of CdTV and TLCrV.

  8. Temporal and radial variation of the solar wind temperature-speed relationship

    NASA Astrophysics Data System (ADS)

    Elliott, H. A.; Henney, C. J.; McComas, D. J.; Smith, C. W.; Vasquez, B. J.

    2012-09-01

    The solar wind temperature (T) and speed (V) are generally well correlated at ˜1 AU, except in Interplanetary Coronal Mass Ejections where this correlation breaks down. We perform a comprehensive analysis of both the temporal and radial variation in the temperature-speed (T-V) relationship of the non-transient wind, and our analysis provides insight into both the causes of the T-V relationship and the sources of the temperature variability. Often at 1 AU the speed-temperature relationship is well represented by a single linear fit over a speed range spanning both the slow and fast wind. However, at times the fast wind from coronal holes can have a different T-V relationship than the slow wind. A good example of this was in 2003 when there was a very large and long-lived outward magnetic polarity coronal hole at low latitudes that emitted wind with speeds as fast as a polar coronal hole. The long-lived nature of the hole made it possible to clearly distinguish that some holes can have a different T-V relationship. In an earlier ACE study, we found that both the compressions and rarefactions T-V curves are linear, but the compression curve is shifted to higher temperatures. By separating compressions and rarefactions prior to determining the radial profiles of the solar wind parameters, the importance of dynamic interactions on the radial evolution of the solar wind parameters is revealed. Although the T-V relationship at 1 AU is often well described by a single linear curve, we find that the T-V relationship continually evolves with distance. Beyond ˜2.5 AU the differences between the compressions and rarefactions are quite significant and affect the shape of the overall T-V distribution to the point that a simple linear fit no longer describes the distribution well. Since additional heating of the ambient solar wind outside of interaction regions can be associated with Alfvénic fluctuations and the turbulent energy cascade, we also estimate the heating rate radial profile from the solar wind speed and temperature measurements.

  9. Accelerated 1 H MRSI using randomly undersampled spiral-based k-space trajectories.

    PubMed

    Chatnuntawech, Itthi; Gagoski, Borjan; Bilgic, Berkin; Cauley, Stephen F; Setsompop, Kawin; Adalsteinsson, Elfar

    2014-07-30

    To develop and evaluate the performance of an acquisition and reconstruction method for accelerated MR spectroscopic imaging (MRSI) through undersampling of spiral trajectories. A randomly undersampled spiral acquisition and sensitivity encoding (SENSE) with total variation (TV) regularization, random SENSE+TV, is developed and evaluated on single-slice numerical phantom, in vivo single-slice MRSI, and in vivo three-dimensional (3D)-MRSI at 3 Tesla. Random SENSE+TV was compared with five alternative methods for accelerated MRSI. For the in vivo single-slice MRSI, random SENSE+TV yields up to 2.7 and 2 times reduction in root-mean-square error (RMSE) of reconstructed N-acetyl aspartate (NAA), creatine, and choline maps, compared with the denoised fully sampled and uniformly undersampled SENSE+TV methods with the same acquisition time, respectively. For the in vivo 3D-MRSI, random SENSE+TV yields up to 1.6 times reduction in RMSE, compared with uniform SENSE+TV. Furthermore, by using random SENSE+TV, we have demonstrated on the in vivo single-slice and 3D-MRSI that acceleration factors of 4.5 and 4 are achievable with the same quality as the fully sampled data, as measured by RMSE of reconstructed NAA map, respectively. With the same scan time, random SENSE+TV yields lower RMSEs of metabolite maps than other methods evaluated. Random SENSE+TV achieves up to 4.5-fold acceleration with comparable data quality as the fully sampled acquisition. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  10. Total variation-based method for radar coincidence imaging with model mismatch for extended target

    NASA Astrophysics Data System (ADS)

    Cao, Kaicheng; Zhou, Xiaoli; Cheng, Yongqiang; Fan, Bo; Qin, Yuliang

    2017-11-01

    Originating from traditional optical coincidence imaging, radar coincidence imaging (RCI) is a staring/forward-looking imaging technique. In RCI, the reference matrix must be computed precisely to reconstruct the image as preferred; unfortunately, such precision is almost impossible due to the existence of model mismatch in practical applications. Although some conventional sparse recovery algorithms are proposed to solve the model-mismatch problem, they are inapplicable to nonsparse targets. We therefore sought to derive the signal model of RCI with model mismatch by replacing the sparsity constraint item with total variation (TV) regularization in the sparse total least squares optimization problem; in this manner, we obtain the objective function of RCI with model mismatch for an extended target. A more robust and efficient algorithm called TV-TLS is proposed, in which the objective function is divided into two parts and the perturbation matrix and scattering coefficients are updated alternately. Moreover, due to the ability of TV regularization to recover sparse signal or image with sparse gradient, TV-TLS method is also applicable to sparse recovering. Results of numerical experiments demonstrate that, for uniform extended targets, sparse targets, and real extended targets, the algorithm can achieve preferred imaging performance both in suppressing noise and in adapting to model mismatch.

  11. Children's exposure to food advertising on free-to-air television: an Asia-Pacific perspective.

    PubMed

    Kelly, Bridget; Hebden, Lana; King, Lesley; Xiao, Yang; Yu, Yang; He, Gengsheng; Li, Liangli; Zeng, Lingxia; Hadi, Hamam; Karupaiah, Tilakavati; Hoe, Ng See; Noor, Mohd Ismail; Yoon, Jihyun; Kim, Hyogyoo

    2016-03-01

    There is an established link between food promotions and children's food purchase and consumption. Children in developing countries may be more vulnerable to food promotions given the relative novelty of advertising in these markets. This study aimed to determine the scope of television food advertising to children across the Asia-Pacific to inform policies to restrict this marketing. Six sites were sampled, including from China, Indonesia, Malaysia and South Korea. At each site, 192 h of television were recorded (4 days, 16 h/day, three channels) from May to October 2012. Advertised foods were categorized as core/healthy, non-core/unhealthy or miscellaneous, and by product type. Twenty-seven percent of advertisements were for food/beverages, and the most frequently advertised product was sugar-sweetened drinks. Rates of non-core food advertising were highest during viewing times most popular with children, when between 3 (South Korea) and 15 (Indonesia) non-core food advertisements were broadcast each hour. Children in the Asia-Pacific are exposed to high volumes of unhealthy food/beverage television advertising. Different policy arrangements for food advertising are likely to contribute to regional variations in advertising patterns. Cities with the lowest advertising rates can be identified as exemplars of good policy practice. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Robust Video Stabilization Using Particle Keypoint Update and l1-Optimized Camera Path

    PubMed Central

    Jeon, Semi; Yoon, Inhye; Jang, Jinbeum; Yang, Seungji; Kim, Jisung; Paik, Joonki

    2017-01-01

    Acquisition of stabilized video is an important issue for various type of digital cameras. This paper presents an adaptive camera path estimation method using robust feature detection to remove shaky artifacts in a video. The proposed algorithm consists of three steps: (i) robust feature detection using particle keypoints between adjacent frames; (ii) camera path estimation and smoothing; and (iii) rendering to reconstruct a stabilized video. As a result, the proposed algorithm can estimate the optimal homography by redefining important feature points in the flat region using particle keypoints. In addition, stabilized frames with less holes can be generated from the optimal, adaptive camera path that minimizes a temporal total variation (TV). The proposed video stabilization method is suitable for enhancing the visual quality for various portable cameras and can be applied to robot vision, driving assistant systems, and visual surveillance systems. PMID:28208622

  13. Real-time demonstration hardware for enhanced DPCM video compression algorithm

    NASA Technical Reports Server (NTRS)

    Bizon, Thomas P.; Whyte, Wayne A., Jr.; Marcopoli, Vincent R.

    1992-01-01

    The lack of available wideband digital links as well as the complexity of implementation of bandwidth efficient digital video CODECs (encoder/decoder) has worked to keep the cost of digital television transmission too high to compete with analog methods. Terrestrial and satellite video service providers, however, are now recognizing the potential gains that digital video compression offers and are proposing to incorporate compression systems to increase the number of available program channels. NASA is similarly recognizing the benefits of and trend toward digital video compression techniques for transmission of high quality video from space and therefore, has developed a digital television bandwidth compression algorithm to process standard National Television Systems Committee (NTSC) composite color television signals. The algorithm is based on differential pulse code modulation (DPCM), but additionally utilizes a non-adaptive predictor, non-uniform quantizer and multilevel Huffman coder to reduce the data rate substantially below that achievable with straight DPCM. The non-adaptive predictor and multilevel Huffman coder combine to set this technique apart from other DPCM encoding algorithms. All processing is done on a intra-field basis to prevent motion degradation and minimize hardware complexity. Computer simulations have shown the algorithm will produce broadcast quality reconstructed video at an average transmission rate of 1.8 bits/pixel. Hardware implementation of the DPCM circuit, non-adaptive predictor and non-uniform quantizer has been completed, providing realtime demonstration of the image quality at full video rates. Video sampling/reconstruction circuits have also been constructed to accomplish the analog video processing necessary for the real-time demonstration. Performance results for the completed hardware compare favorably with simulation results. Hardware implementation of the multilevel Huffman encoder/decoder is currently under development along with implementation of a buffer control algorithm to accommodate the variable data rate output of the multilevel Huffman encoder. A video CODEC of this type could be used to compress NTSC color television signals where high quality reconstruction is desirable (e.g., Space Station video transmission, transmission direct-to-the-home via direct broadcast satellite systems or cable television distribution to system headends and direct-to-the-home).

  14. Study of magnetic perturbations on SEC vidicon tubes. [large space telescope

    NASA Technical Reports Server (NTRS)

    Long, D. C.; Zucchino, P.; Lowrance, J.

    1973-01-01

    A laboratory measurements program was conducted to determine the tolerances that must be imposed to achieve optimum performance from SEC-vidicon data sensors in the LST mission. These measurements along with other data were used to formulate recommendations regarding the necessary telemetry and remote control for the television data sensors when in orbit. The study encompassed the following tasks: (1) Conducted laboratory measurements of the perturbations which an external magnetic field produces on a magnetically focused, SEC-vidicon. Evaluated shielding approaches. (2) Experimentally evaluated the effects produced on overall performance by variations of the tube electrode potentials, and the focus, deflection and alignment fields. (3) Recommended the extent of ground control of camera parameters and camera parameter telemetry required for optimizing the performance of the television system in orbit. The experimental data are summarized in a set of graphs.

  15. Vitamin panacea: Is advertising fueling demand for products with uncertain scientific benefit?

    PubMed

    Eisenberg, Matthew D; Avery, Rosemary J; Cantor, Jonathan H

    2017-09-01

    This study examines the effect of advertising on demand for vitamins-products with spiraling sales despite little evidence of efficacy. We merge seven years (2003-2009) of advertising data from Kantar Media with the Simmons National Consumer Survey to estimate individual-level vitamin print and television ad exposure effects. Identification relies on exploiting exogenous variation in year-to-year advertising exposure by controlling for each individual's unique media consumption. We find that increasing advertising exposure from zero to the mean number of ads increases the probability of consumption by 1.2 and 0.8% points (or 2 and 1.4%) in print and television respectively. Stratifications by the presence of health conditions suggests that in print demand is being driven by both healthy and sick individuals. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Uncommon presentations of tinea versicolor

    PubMed Central

    Varada, Sowmya; Dabade, Tushar; Loo, Daniel S.

    2014-01-01

    Tinea versicolor (TV) is a common cutaneous fungal infection characterized by superficial scaling and a mild disturbance of skin pigmentation. It typically affects the chest, upper back, and shoulders. However, involvement of more unusual regions of the body such as the face and scalp, arms and legs, intertriginous sites, genitalia, areolae, and palms and soles has been reported. This report details two such cases observed at our institution: a 32-year-old woman with involvement of the popliteal fossa and a 16-year-old boy with involvement of the groin. The clinician must be aware of these variations in location and perform the appropriate diagnostic workup when lesions have the characteristic morphology of TV despite an unusual location. The etiology, pathophysiology, and epidemiology of TV are reviewed and current literature describing other instances of TV in uncommon locations is discussed. PMID:25126470

  17. Does Digital Video Advertising Increase Population-Level Reach of Multimedia Campaigns? Evidence From the 2013 Tips From Former Smokers Campaign

    PubMed Central

    Shafer, Paul R; Rodes, Robert; Kim, Annice; Hansen, Heather; Patel, Deesha; Coln, Caryn; Beistle, Diane

    2016-01-01

    Background Federal and state public health agencies in the United States are increasingly using digital advertising and social media to promote messages from broader multimedia campaigns. However, little evidence exists on population-level campaign awareness and relative cost efficiencies of digital advertising in the context of a comprehensive public health education campaign. Objective Our objective was to compare the impact of increased doses of digital video and television advertising from the 2013 Tips From Former Smokers (Tips) campaign on overall campaign awareness at the population level. We also compared the relative cost efficiencies across these media platforms. Methods We used data from a large national online survey of approximately 15,000 US smokers conducted in 2013 immediately after the conclusion of the 2013 Tips campaign. These data were used to compare the effects of variation in media dose of digital video and television advertising on population-level awareness of the Tips campaign. We implemented higher doses of digital video among selected media markets and randomly selected other markets to receive similar higher doses of television ads. Multivariate logistic regressions estimated the odds of overall campaign awareness via digital or television format as a function of higher-dose media in each market area. All statistical tests used the .05 threshold for statistical significance and the .10 level for marginal nonsignificance. We used adjusted advertising costs for the additional doses of digital and television advertising to compare the cost efficiencies of digital and television advertising on the basis of costs per percentage point of population awareness generated. Results Higher-dose digital video advertising was associated with 94% increased odds of awareness of any ad online relative to standard-dose markets (P<.001). Higher-dose digital advertising was associated with a marginally nonsignificant increase (46%) in overall campaign awareness regardless of media format (P=.09). Higher-dose television advertising was associated with 81% increased odds of overall ad awareness regardless of media format (P<.001). Increased doses of television advertising were also associated with significantly higher odds of awareness of any ad on television (P<.001) and online (P=.04). The adjusted cost of each additional percentage point of population-level reach generated by higher doses of advertising was approximately US $440,000 for digital advertising and US $1 million for television advertising. Conclusions Television advertising generated relatively higher levels of overall campaign awareness. However, digital video was relatively more cost efficient for generating awareness. These results suggest that digital video may be used as a cost-efficient complement to traditional advertising modes (eg, television), but digital video should not replace television given the relatively smaller audience size of digital video viewers. PMID:27627853

  18. Does Digital Video Advertising Increase Population-Level Reach of Multimedia Campaigns? Evidence From the 2013 Tips From Former Smokers Campaign.

    PubMed

    Davis, Kevin C; Shafer, Paul R; Rodes, Robert; Kim, Annice; Hansen, Heather; Patel, Deesha; Coln, Caryn; Beistle, Diane

    2016-09-14

    Federal and state public health agencies in the United States are increasingly using digital advertising and social media to promote messages from broader multimedia campaigns. However, little evidence exists on population-level campaign awareness and relative cost efficiencies of digital advertising in the context of a comprehensive public health education campaign. Our objective was to compare the impact of increased doses of digital video and television advertising from the 2013 Tips From Former Smokers (Tips) campaign on overall campaign awareness at the population level. We also compared the relative cost efficiencies across these media platforms. We used data from a large national online survey of approximately 15,000 US smokers conducted in 2013 immediately after the conclusion of the 2013 Tips campaign. These data were used to compare the effects of variation in media dose of digital video and television advertising on population-level awareness of the Tips campaign. We implemented higher doses of digital video among selected media markets and randomly selected other markets to receive similar higher doses of television ads. Multivariate logistic regressions estimated the odds of overall campaign awareness via digital or television format as a function of higher-dose media in each market area. All statistical tests used the .05 threshold for statistical significance and the .10 level for marginal nonsignificance. We used adjusted advertising costs for the additional doses of digital and television advertising to compare the cost efficiencies of digital and television advertising on the basis of costs per percentage point of population awareness generated. Higher-dose digital video advertising was associated with 94% increased odds of awareness of any ad online relative to standard-dose markets (P<.001). Higher-dose digital advertising was associated with a marginally nonsignificant increase (46%) in overall campaign awareness regardless of media format (P=.09). Higher-dose television advertising was associated with 81% increased odds of overall ad awareness regardless of media format (P<.001). Increased doses of television advertising were also associated with significantly higher odds of awareness of any ad on television (P<.001) and online (P=.04). The adjusted cost of each additional percentage point of population-level reach generated by higher doses of advertising was approximately US $440,000 for digital advertising and US $1 million for television advertising. Television advertising generated relatively higher levels of overall campaign awareness. However, digital video was relatively more cost efficient for generating awareness. These results suggest that digital video may be used as a cost-efficient complement to traditional advertising modes (eg, television), but digital video should not replace television given the relatively smaller audience size of digital video viewers.

  19. Testing of a Spray-bar Thermodynamic Vent System in Liquid Nitrogen

    NASA Technical Reports Server (NTRS)

    Flachbart, R. H.; Hastings, L. J.; Hedayat, A.; Nelson, S. L.; Tucker, S. P.

    2005-01-01

    To support development of a microgravity pressure control capability for liquid oxygen, thermodynamic vent system (TVS) testing was conducted at Marshall Space Flight Center (MSFC) using liquid nitrogen (LN2) as a LOX simulant. The spray bar TVS hardware used was originally designed by the Boeing Company for testing in liquid hydrogen (LH2). With this concept, a small portion of the tank fluid is passed through a Joule-Thomson (J-T) device, and then through a longitudinal spray bar mixed-heat exchanger in order to cool the bulk fluid. To accommodate the larger mass flow rates associated with LN2, the TVS hardware was modified by replacing the recirculation pump with an LN2 compatible pump and replacing the J-T valve. The primary advantage of the spray-bar configuration is that tank pressure control can be achieved independent of liquid and vapor location, enhancing the applicability of ground test data to microgravity conditions. Performance testing revealed that the spray-bar TVS was effective in controlling tank pressure within a 6.89 kPa band for fill levels of 90%, 50%, and 25%. Tests were also conducted with gaseous helium (GHe) in the ullage. The TVS operated nominally with GHe in the ullage, with performance similar to the tests with gaseous nitrogen (GN2). Testing demonstrated that the spray-bar TVS design was flexible enough for use in two different propellants with minimal hardware modifications.

  20. 78 FR 45927 - Information Collection Being Reviewed by the Federal Communications Commission Under Delegated...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-30

    ... quality, utility, and clarity of the information collected; ways to minimize the burden of the collection... noncommercial FM and TV broadcast station is required to file an Ownership Report for Noncommercial Educational...

  1. 76 FR 6133 - Notice of Public Information Collection(s) Being Reviewed by the Federal Communications...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-03

    ... enhance the quality, utility, and clarity of the information collected; (d) ways to minimize the burden of..., Additional Procedures in Proceedings for Amendment of FM, TV or Air-Ground Table of Allotments. Type of...

  2. 78 FR 45926 - Information Collection Being Submitted to the Office of Management and Budget for Review and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-30

    ... the quality, utility, and clarity of the information collected; ways to minimize the burden of the... certain equipment manufacturers file information concerning the testing of TV receivers, which tune to UHF...

  3. Developmental Trajectories of Physical Activity, Sports, and Television Viewing During Childhood to Young Adulthood: Iowa Bone Development Study.

    PubMed

    Kwon, Soyang; Janz, Kathleen F; Letuchy, Elena M; Burns, Trudy L; Levy, Steven M

    2015-07-01

    The diverse developmental patterns of obesogenic behaviors during childhood and adolescence can be better understood by using new analytic approaches to assess the heterogeneity in variation during growth and development and to map the clustering of behavior patterns. To identify distinct trajectories of daily time spent in moderate- to vigorous-intensity physical activity (MVPA) from ages 5 to 19 years and to examine the associations of MVPA trajectories with sports participation and television viewing trajectories. Cohort members in the prospective population-based Iowa Bone Development Study participated in MVPA assessments via accelerometry from September 16, 1998, to December 9, 2013, at ages 5, 8, 11, 13, 15, 17, and 19 years and completed a questionnaire every 6 months on sports participation and daily time spent in television viewing. Trajectories of MVPA (minutes per day), participation in organized sports (yes or no), and television viewing time (hours per day). Based on the data from 537 participants (50.1% females; 94.6% white), we identified 4 MVPA trajectories: consistently inactive (14.9%), consistently active (18.1%), decreasing moderate physical activity (52.9%), and substantially decreasing high physical activity (14.1%). All participants in the consistently inactive trajectory also followed a trajectory of no participation in sports. The consistently active trajectory was associated with decreasing an already low television viewing trajectory (P < .001). This study provided a nuanced look at the known decrease in MVPA during childhood and adolescence. Sports participation could be a critical way to avoid the consistently inactive pattern. Most important, we identified a subset of participants who maintained a seemingly healthy level of MVPA from childhood to young adulthood. The developmental pathways of physical activity and television viewing behaviors could be related. Additional studies should examine the determinants and health consequences of these specific MVPA trajectories.

  4. Improving the color fidelity of cameras for advanced television systems

    NASA Astrophysics Data System (ADS)

    Kollarits, Richard V.; Gibbon, David C.

    1992-08-01

    In this paper we compare the accuracy of the color information obtained from television cameras using three and five wavelength bands. This comparison is based on real digital camera data. The cameras are treated as colorimeters whose characteristics are not linked to that of the display. The color matrices for both cameras were obtained by identical optimization procedures that minimized the color error The color error for the five band camera is 2. 5 times smaller than that obtained from the three band camera. Visual comparison of color matches on a characterized color monitor indicate that the five band camera is capable of color measurements that produce no significant visual error on the display. Because the outputs from the five band camera are reduced to the normal three channels conventionally used for display there need be no increase in signal handling complexity outside the camera. Likewise it is possible to construct a five band camera using only three sensors as in conventional cameras. The principal drawback of the five band camera is the reduction in effective camera sensitivity by about 3/4 of an I stop. 1.

  5. A spatially-variant deconvolution method based on total variation for optical coherence tomography images

    NASA Astrophysics Data System (ADS)

    Almasganj, Mohammad; Adabi, Saba; Fatemizadeh, Emad; Xu, Qiuyun; Sadeghi, Hamid; Daveluy, Steven; Nasiriavanaki, Mohammadreza

    2017-03-01

    Optical Coherence Tomography (OCT) has a great potential to elicit clinically useful information from tissues due to its high axial and transversal resolution. In practice, an OCT setup cannot reach to its theoretical resolution due to imperfections of its components, which make its images blurry. The blurriness is different alongside regions of image; thus, they cannot be modeled by a unique point spread function (PSF). In this paper, we investigate the use of solid phantoms to estimate the PSF of each sub-region of imaging system. We then utilize Lucy-Richardson, Hybr and total variation (TV) based iterative deconvolution methods for mitigating occurred spatially variant blurriness. It is shown that the TV based method will suppress the so-called speckle noise in OCT images better than the two other approaches. The performance of proposed algorithm is tested on various samples, including several skin tissues besides the test image blurred with synthetic PSF-map, demonstrating qualitatively and quantitatively the advantage of TV based deconvolution method using spatially-variant PSF for enhancing image quality.

  6. A novel scatter-matrix eigenvalues-based total variation (SMETV) regularization for medical image restoration

    NASA Astrophysics Data System (ADS)

    Huang, Zhenghua; Zhang, Tianxu; Deng, Lihua; Fang, Hao; Li, Qian

    2015-12-01

    Total variation(TV) based on regularization has been proven as a popular and effective model for image restoration, because of its ability of edge preserved. However, as the TV favors a piece-wise constant solution, the processing results in the flat regions of the image are easily produced "staircase effects", and the amplitude of the edges will be underestimated; the underlying cause of the problem is that the regularization parameter can not be changeable with spatial local information of image. In this paper, we propose a novel Scatter-matrix eigenvalues-based TV(SMETV) regularization with image blind restoration algorithm for deblurring medical images. The spatial information in different image regions is incorporated into regularization by using the edge indicator called difference eigenvalue to distinguish edges from flat areas. The proposed algorithm can effectively reduce the noise in flat regions as well as preserve the edge and detailed information. Moreover, it becomes more robust with the change of the regularization parameter. Extensive experiments demonstrate that the proposed approach produces results superior to most methods in both visual image quality and quantitative measures.

  7. New astronomy space experiments with television scanning.

    NASA Technical Reports Server (NTRS)

    Davis, R. J.

    1971-01-01

    Application of data from the Celescope Catalog of Ultraviolet Observations to various problems of stellar and interstellar astrophysics. These include refinements in the incorporation of line blanketing in theoretical stellar-atmosphere models, variations in the law of interstellar extinction from one region of the sky to another, and selection and identification of various types of peculiar stars for further investigation. In addition, the data were analyzed to determine the photometric and astrometric accuracy of the Celescope equipment.

  8. Prevalence and causes of low birth weight in India.

    PubMed

    Bharati, P; Pal, M; Bandyopadhyay, M; Bhakta, A; Chakraborty, S; Bharati, P

    2011-12-01

    The aims of the study are (i) to understand inter-zone and interstate variation of low birth weight (LBW) and (ii) to determine the key variables to reduce LBW in India. Using the latest National Family Health Survey (NFHS) data of 2005-06 which showed the percentage distribution of LBW infants, ANOVA and post-hoc test were performed to determine the spatial variation of birth weight. The covariates which influence LBW fell into three categories: (i) social variables which included location, mother's education, religion, access of mothers to newspapers, television and family structure; (ii) economic variable namely, the wealth index, and (iii) biological variables which consisted of sex of the children, birth order, and mother's body mass index (BMI). Three models of Logistic regression were carried out to examine the influence of the combinations of these direct and indirect factors. In India, nearly 20% of new borns have LBW. Males have less frequency of LBW than females. The North-east zone has the lowest prevalence of LBW while the north zone has the highest. Mother's education, access to TV and nuclear family, and intake of iron tablets are the most important socio-economic influences on the determination of birth weight in India. It is essential to provide proper diet and nutritional care of mothers during pregnancy. Increased education of mothers through programmes in TV and newspapers articles have significant roles to play in reducing LBW in India.

  9. Monochromatic-beam-based dynamic X-ray microtomography based on OSEM-TV algorithm.

    PubMed

    Xu, Liang; Chen, Rongchang; Yang, Yiming; Deng, Biao; Du, Guohao; Xie, Honglan; Xiao, Tiqiao

    2017-01-01

    Monochromatic-beam-based dynamic X-ray computed microtomography (CT) was developed to observe evolution of microstructure inside samples. However, the low flux density results in low efficiency in data collection. To increase efficiency, reducing the number of projections should be a practical solution. However, it has disadvantages of low image reconstruction quality using the traditional filtered back projection (FBP) algorithm. In this study, an iterative reconstruction method using an ordered subset expectation maximization-total variation (OSEM-TV) algorithm was employed to address and solve this problem. The simulated results demonstrated that normalized mean square error of the image slices reconstructed by the OSEM-TV algorithm was about 1/4 of that by FBP. Experimental results also demonstrated that the density resolution of OSEM-TV was high enough to resolve different materials with the number of projections less than 100. As a result, with the introduction of OSEM-TV, the monochromatic-beam-based dynamic X-ray microtomography is potentially practicable for the quantitative and non-destructive analysis to the evolution of microstructure with acceptable efficiency in data collection and reconstructed image quality.

  10. Effect of electronic media on children.

    PubMed

    Ray, Munni; Jat, Kana Ram

    2010-07-01

    Radio, television (TV), movies, video games, cell phones, and computer networks have assumed central roles in our children's daily lives. The media has demonstrated potentially profound effects, both positive and negative, on children's cognitive, social, and behavioral development. Considering the increasing exposure of children to newer forms of media, we decided to review the current literature on the effects of media on child health both in the Western countries and India. It is widely accepted that media has profound influence on child health, including violence, obesity, tobacco and alcohol use, and risky sexual behaviors. Simultaneously, media may have some positive effects on child health. We need to find ways to optimize the role of media in our society, taking advantage of their positive attributes and minimizing their negative ones. We need to understand better how to reverse the negative impact of media and make it more positive.

  11. Advertising to children initiatives have not reduced unhealthy food advertising on Australian television.

    PubMed

    Watson, Wendy L; Lau, Vivien; Wellard, Lyndal; Hughes, Clare; Chapman, Kathryn

    2017-12-01

    In response to rising childhood obesity rates, the Australian food industry implemented two initiatives in 2009 to reduce the marketing of unhealthy food to children. This study evaluated the efficacy of these initiatives on the rate of unhealthy food advertising to children on Australian television. The rates of food advertisements on three free-to-air commercial television channels and a youth-oriented digital channel in Sydney, Australia were analysed over 2 weekdays (16 h) and two weekend days (22 h). Advertisements were categorized according to the healthiness of foods advertised (non-core, core, miscellaneous) and signatory status to the food industry advertising initiatives. Total food advertising rates for the three channels increased from 5.5/h in 2011 to 7.3/h in 2015, due to an increase of 0.8/h for both core and miscellaneous foods. The rate of non-core food advertisements in 2015 (3.1/h) was similar to 2011 (3.0/h). The youth-oriented channel had fewer total food advertisements (3.7/h versus 7.3/h) but similar fast-food advertisement rates (1.3/h versus 1.3/h). There was no change in the rate of unhealthy food advertising since 2011, suggesting minimal impact of the current food industry initiatives on reducing children's exposure to unhealthy food advertising. © The Author 2017. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  12. 75 FR 54877 - Notice of Public Information Collection(s) Being Reviewed by the Federal Communications...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-09

    ... enhance the quality, utility, and clarity of the information collected; (d) ways to minimize the burden of... Class A TV Broadcast Station, FCC Form 301-CA. Form Number: FCC 301-CA. Type of Review: Extension of a...

  13. Exposure of children and adolescents to alcohol advertising on Australian metropolitan free-to-air television.

    PubMed

    Fielder, Lynda; Donovan, Robert J; Ouschan, Robyn

    2009-07-01

    This study investigated the exposure of underage youth to alcohol television advertising on metropolitan free-to-air television in the five mainland capital city markets of Australia. Exposure levels (target audience rating points; TARPs) were obtained for all alcohol advertisements screened from November 2005 to October 2006 in each capital city market for: children 0-12 years; underage teens 13-17 years; young adults 18-24 years; and mature adults 25+ years. The 30 most exposed advertisements across age groups were then content-analysed for elements appealing to children and underage youth. In each of the five metropolitan markets, mature adults were most exposed to alcohol advertising. Children were exposed to one-third the level of mature adults and underage teens to approximately the same level as young adults. However, there was considerable variation in media weight between markets, such that underage teens in two markets had higher advertising TARPs than young adults in other markets. All 30 highest exposed advertisements contained at least one element known to appeal to children and underage youth, with 23 containing two or more such elements. Fifteen of the 30 advertisements featured an animal. The self-regulation system in Australia does not protect children and youth from exposure to alcohol advertising, much of which contains elements appealing to these groups.

  14. The effect of variable S/N on the subjective evaluation of protection ratios for direct-TV satellite services

    NASA Technical Reports Server (NTRS)

    Groumpos, P. P.; Dimitriadis, B. D.; Whyte, W.

    1984-01-01

    Protection ratios, the ratio of wanted-to-unwanted signal power at the receiver input, for acceptable picture quality were experimentally evaluated for four different still pictures. The variation of carrier-to-interference, C/I, with picture impairment grade is investigated when different noise levels are present. Results are presented which show the relationship between the impairment grade and the C/I ratio for FM/TV co-channel systems under variable S/N conditions.

  15. [Sleep health education for elderly people].

    PubMed

    Miyazaki, Soichiro; Nishiyama, Akiko

    2015-06-01

    Successful aging is characterized by minimal age-associated loss of the physiological functions of sleep and circadian clock. Sleep health education is necessary to have normal, quality nighttime sleep and full daytime alertness. Elderly people show changes of sleep parameters, accompanied by increased napping. Many studies have reported that daytime sleepiness or napping in elderly people could have potentially serious effects such as dementia and life-style related diseases. The main topics of sleep health education for elderly people are as follows: Right knowledge of sleep mechanism, understanding the bad influence of excessive napping, the effects of light on the circadian rhythm and negative effects of caffeine, alcohol and television.

  16. Mixed Gaussian-Impulse Noise Image Restoration Via Total Variation

    DTIC Science & Technology

    2012-05-01

    deblurring under impulse noise ,” J. Math. Imaging Vis., vol. 36, pp. 46–53, January 2010. [5] B. Li, Q. Liu, J. Xu, and X. Luo, “A new method for removing......Several Total Variation (TV) regularization methods have recently been proposed to address denoising under mixed Gaussian and impulse noise . While

  17. Sparsity-based acoustic inversion in cross-sectional multiscale optoacoustic imaging.

    PubMed

    Han, Yiyong; Tzoumas, Stratis; Nunes, Antonio; Ntziachristos, Vasilis; Rosenthal, Amir

    2015-09-01

    With recent advancement in hardware of optoacoustic imaging systems, highly detailed cross-sectional images may be acquired at a single laser shot, thus eliminating motion artifacts. Nonetheless, other sources of artifacts remain due to signal distortion or out-of-plane signals. The purpose of image reconstruction algorithms is to obtain the most accurate images from noisy, distorted projection data. In this paper, the authors use the model-based approach for acoustic inversion, combined with a sparsity-based inversion procedure. Specifically, a cost function is used that includes the L1 norm of the image in sparse representation and a total variation (TV) term. The optimization problem is solved by a numerically efficient implementation of a nonlinear gradient descent algorithm. TV-L1 model-based inversion is tested in the cross section geometry for numerically generated data as well as for in vivo experimental data from an adult mouse. In all cases, model-based TV-L1 inversion showed a better performance over the conventional Tikhonov regularization, TV inversion, and L1 inversion. In the numerical examples, the images reconstructed with TV-L1 inversion were quantitatively more similar to the originating images. In the experimental examples, TV-L1 inversion yielded sharper images and weaker streak artifact. The results herein show that TV-L1 inversion is capable of improving the quality of highly detailed, multiscale optoacoustic images obtained in vivo using cross-sectional imaging systems. As a result of its high fidelity, model-based TV-L1 inversion may be considered as the new standard for image reconstruction in cross-sectional imaging.

  18. Obesogenic television food advertising to children in Malaysia: sociocultural variations

    PubMed Central

    Ng, See H.; Kelly, Bridget; Se, Chee H.; Chinna, Karuthan; Sameeha, Mohd Jamil; Krishnasamy, Shanthi; MN, Ismail; Karupaiah, Tilakavati

    2014-01-01

    Background Food advertising on television (TV) is well known to influence children's purchasing requests and models negative food habits in Western countries. Advertising of unhealthy foods is a contributor to the obesogenic environment that is a key driver of rising rates of childhood obesity. Children in developing countries are more at risk of being targeted by such advertising, as there is a huge potential for market growth of unhealthy foods concomitant with poor regulatory infrastructure. Further, in developing countries with multi-ethnic societies, information is scarce on the nature of TV advertising targeting children. Objectives To measure exposure and power of TV food marketing to children on popular multi-ethnic TV stations in Malaysia. Design Ethnic-specific popular TV channels were identified using industry data. TV transmissions were recorded for each channel from November 2012 to August 2013 (16 hr/day) for randomly selected weekdays and weekend days during normal days and repeated during school holidays (n=88 days). Coded food/beverage advertisements were grouped into core (healthy), non-core (non-healthy), or miscellaneous (unclassified) food categories. Peak viewing time (PVT) and persuasive marketing techniques were identified. Results Non-core foods were predominant in TV food advertising, and rates were greater during school holidays compared to normal days (3.51 vs 1.93 food ads/hr/channel, p<0.001). During normal days’ PVT, the ratio of non-core to core food advertising was higher (3.25 food ads/hr/channel), and this more than trebled during school holidays to 10.25 food ads/hr/channel. Popular channels for Indian children had the lowest rate of food advertising relative to other ethnic groups. However, sugary drinks remained a popular non-core product advertised across all broadcast periods and channels. Notably, promotional characters doubled for non-core foods during school holidays compared to normal days (1.91 vs 0.93 food ads/hr/channel, p<0.001). Conclusions This study highlights non-core food advertising, and predominantly sugary drinks are commonly screened on Malaysian TV channels. The majority of these sugary drinks were advertised by multinational companies, and this observation warrants regulatory attention. PMID:25141835

  19. Obesogenic television food advertising to children in Malaysia: sociocultural variations.

    PubMed

    Ng, See H; Kelly, Bridget; Se, Chee H; Chinna, Karuthan; Sameeha, Mohd Jamil; Krishnasamy, Shanthi; Ismail, M N; Karupaiah, Tilakavati

    2014-01-01

    Food advertising on television (TV) is well known to influence children's purchasing requests and models negative food habits in Western countries. Advertising of unhealthy foods is a contributor to the obesogenic environment that is a key driver of rising rates of childhood obesity. Children in developing countries are more at risk of being targeted by such advertising, as there is a huge potential for market growth of unhealthy foods concomitant with poor regulatory infrastructure. Further, in developing countries with multi-ethnic societies, information is scarce on the nature of TV advertising targeting children. To measure exposure and power of TV food marketing to children on popular multi-ethnic TV stations in Malaysia. Ethnic-specific popular TV channels were identified using industry data. TV transmissions were recorded for each channel from November 2012 to August 2013 (16 hr/day) for randomly selected weekdays and weekend days during normal days and repeated during school holidays (n=88 days). Coded food/beverage advertisements were grouped into core (healthy), non-core (non-healthy), or miscellaneous (unclassified) food categories. Peak viewing time (PVT) and persuasive marketing techniques were identified. Non-core foods were predominant in TV food advertising, and rates were greater during school holidays compared to normal days (3.51 vs 1.93 food ads/hr/channel, p<0.001). During normal days' PVT, the ratio of non-core to core food advertising was higher (3.25 food ads/hr/channel), and this more than trebled during school holidays to 10.25 food ads/hr/channel. Popular channels for Indian children had the lowest rate of food advertising relative to other ethnic groups. However, sugary drinks remained a popular non-core product advertised across all broadcast periods and channels. Notably, promotional characters doubled for non-core foods during school holidays compared to normal days (1.91 vs 0.93 food ads/hr/channel, p<0.001). This study highlights non-core food advertising, and predominantly sugary drinks are commonly screened on Malaysian TV channels. The majority of these sugary drinks were advertised by multinational companies, and this observation warrants regulatory attention.

  20. SU-F-BRCD-09: Total Variation (TV) Based Fast Convergent Iterative CBCT Reconstruction with GPU Acceleration.

    PubMed

    Xu, Q; Yang, D; Tan, J; Anastasio, M

    2012-06-01

    To improve image quality and reduce imaging dose in CBCT for radiation therapy applications and to realize near real-time image reconstruction based on use of a fast convergence iterative algorithm and acceleration by multi-GPUs. An iterative image reconstruction that sought to minimize a weighted least squares cost function that employed total variation (TV) regularization was employed to mitigate projection data incompleteness and noise. To achieve rapid 3D image reconstruction (< 1 min), a highly optimized multiple-GPU implementation of the algorithm was developed. The convergence rate and reconstruction accuracy were evaluated using a modified 3D Shepp-Logan digital phantom and a Catphan-600 physical phantom. The reconstructed images were compared with the clinical FDK reconstruction results. Digital phantom studies showed that only 15 iterations and 60 iterations are needed to achieve algorithm convergence for 360-view and 60-view cases, respectively. The RMSE was reduced to 10-4 and 10-2, respectively, by using 15 iterations for each case. Our algorithm required 5.4s to complete one iteration for the 60-view case using one Tesla C2075 GPU. The few-view study indicated that our iterative algorithm has great potential to reduce the imaging dose and preserve good image quality. For the physical Catphan studies, the images obtained from the iterative algorithm possessed better spatial resolution and higher SNRs than those obtained from by use of a clinical FDK reconstruction algorithm. We have developed a fast convergence iterative algorithm for CBCT image reconstruction. The developed algorithm yielded images with better spatial resolution and higher SNR than those produced by a commercial FDK tool. In addition, from the few-view study, the iterative algorithm has shown great potential for significantly reducing imaging dose. We expect that the developed reconstruction approach will facilitate applications including IGART and patient daily CBCT-based treatment localization. © 2012 American Association of Physicists in Medicine.

  1. Preconditioned Alternating Projection Algorithms for Maximum a Posteriori ECT Reconstruction

    PubMed Central

    Krol, Andrzej; Li, Si; Shen, Lixin; Xu, Yuesheng

    2012-01-01

    We propose a preconditioned alternating projection algorithm (PAPA) for solving the maximum a posteriori (MAP) emission computed tomography (ECT) reconstruction problem. Specifically, we formulate the reconstruction problem as a constrained convex optimization problem with the total variation (TV) regularization. We then characterize the solution of the constrained convex optimization problem and show that it satisfies a system of fixed-point equations defined in terms of two proximity operators raised from the convex functions that define the TV-norm and the constrain involved in the problem. The characterization (of the solution) via the proximity operators that define two projection operators naturally leads to an alternating projection algorithm for finding the solution. For efficient numerical computation, we introduce to the alternating projection algorithm a preconditioning matrix (the EM-preconditioner) for the dense system matrix involved in the optimization problem. We prove theoretically convergence of the preconditioned alternating projection algorithm. In numerical experiments, performance of our algorithms, with an appropriately selected preconditioning matrix, is compared with performance of the conventional MAP expectation-maximization (MAP-EM) algorithm with TV regularizer (EM-TV) and that of the recently developed nested EM-TV algorithm for ECT reconstruction. Based on the numerical experiments performed in this work, we observe that the alternating projection algorithm with the EM-preconditioner outperforms significantly the EM-TV in all aspects including the convergence speed, the noise in the reconstructed images and the image quality. It also outperforms the nested EM-TV in the convergence speed while providing comparable image quality. PMID:23271835

  2. Preconditioned alternating projection algorithms for maximum a posteriori ECT reconstruction

    NASA Astrophysics Data System (ADS)

    Krol, Andrzej; Li, Si; Shen, Lixin; Xu, Yuesheng

    2012-11-01

    We propose a preconditioned alternating projection algorithm (PAPA) for solving the maximum a posteriori (MAP) emission computed tomography (ECT) reconstruction problem. Specifically, we formulate the reconstruction problem as a constrained convex optimization problem with the total variation (TV) regularization. We then characterize the solution of the constrained convex optimization problem and show that it satisfies a system of fixed-point equations defined in terms of two proximity operators raised from the convex functions that define the TV-norm and the constraint involved in the problem. The characterization (of the solution) via the proximity operators that define two projection operators naturally leads to an alternating projection algorithm for finding the solution. For efficient numerical computation, we introduce to the alternating projection algorithm a preconditioning matrix (the EM-preconditioner) for the dense system matrix involved in the optimization problem. We prove theoretically convergence of the PAPA. In numerical experiments, performance of our algorithms, with an appropriately selected preconditioning matrix, is compared with performance of the conventional MAP expectation-maximization (MAP-EM) algorithm with TV regularizer (EM-TV) and that of the recently developed nested EM-TV algorithm for ECT reconstruction. Based on the numerical experiments performed in this work, we observe that the alternating projection algorithm with the EM-preconditioner outperforms significantly the EM-TV in all aspects including the convergence speed, the noise in the reconstructed images and the image quality. It also outperforms the nested EM-TV in the convergence speed while providing comparable image quality.

  3. Median prior constrained TV algorithm for sparse view low-dose CT reconstruction.

    PubMed

    Liu, Yi; Shangguan, Hong; Zhang, Quan; Zhu, Hongqing; Shu, Huazhong; Gui, Zhiguo

    2015-05-01

    It is known that lowering the X-ray tube current (mAs) or tube voltage (kVp) and simultaneously reducing the total number of X-ray views (sparse view) is an effective means to achieve low-dose in computed tomography (CT) scan. However, the associated image quality by the conventional filtered back-projection (FBP) usually degrades due to the excessive quantum noise. Although sparse-view CT reconstruction algorithm via total variation (TV), in the scanning protocol of reducing X-ray tube current, has been demonstrated to be able to result in significant radiation dose reduction while maintain image quality, noticeable patchy artifacts still exist in reconstructed images. In this study, to address the problem of patchy artifacts, we proposed a median prior constrained TV regularization to retain the image quality by introducing an auxiliary vector m in register with the object. Specifically, the approximate action of m is to draw, in each iteration, an object voxel toward its own local median, aiming to improve low-dose image quality with sparse-view projection measurements. Subsequently, an alternating optimization algorithm is adopted to optimize the associative objective function. We refer to the median prior constrained TV regularization as "TV_MP" for simplicity. Experimental results on digital phantoms and clinical phantom demonstrated that the proposed TV_MP with appropriate control parameters can not only ensure a higher signal to noise ratio (SNR) of the reconstructed image, but also its resolution compared with the original TV method. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Telling stories about abortion: abortion-related plots in American film and television, 1916-2013.

    PubMed

    Sisson, Gretchen; Kimport, Katrina

    2014-05-01

    Popular discourse on abortion in film and television assumes that abortions are under- and misrepresented. Research indicates that such representations influence public perception of abortion care and may play a role in the production of social myths around abortion, with consequences for women's experience of abortion. To date, abortion plotlines in American film and television have not been systematically tracked and analyzed. A comprehensive online search was conducted to identify all representations of pregnancy decision making and abortion in American film and television through January 2013. Search results were coded for year, pregnancy decision and mortality outcome. A total of 310 plotlines were identified, with an overall upward trend over time in the number of representations of abortion decision making. Of these plotlines, 173 (55.8%) resulted in abortion, 80 (25.8%) in parenting, 13 (4.2%) in adoption and 21 (6.7%) in pregnancy loss, and 16 (5.1%) were unresolved. A total of 13.5% (n=42) of stories ended with the death of the woman who considered an abortion, whether or not she obtained one. Abortion-related plotlines occur more frequently than popular discourse assumes. Year-to-year variation in frequency suggests an interactive relationship between media representations, cultural attitudes and policies around abortion regulation, consistent with cultural theory of the relationship between media products and social beliefs. Patterns of outcomes and rates of mortality are not representative of real experience and may contribute to social myths around abortion. The narrative linking of pregnancy termination with mortality is of particular note, supporting the social myth associating abortion with death. This analysis empirically describes the number of abortion-related plotlines in American film and television. It contributes to the systematic evaluation of the portrayal of abortion in popular culture and provides abortion care professionals and advocates with an initial accurate window into cultural stories being told about abortion. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. ‘A matter of faith, not science’: analysis of media coverage of prostate cancer screening in Australian news media 2003-2006

    PubMed Central

    MacKenzie, Ross; Chapman, Simon; Holding, Simon; McGeechan, Kevin

    2007-01-01

    Objective Despite a near universal absence of evidence-based policies supporting population screening for prostate cancer, the prostate-specific antigen (PSA) test is aggressively promoted in the media as a life-saving form of screening. The objective of this study was to examine media coverage of prostate-cancer screening in Australia. Design Frame analysis of all direct or attributed quotes about prostate cancer. Setting Australian capital city newspapers (February 2003-December 2006) and Sydney television news (January 2003-December 2006). Main outcome measures Quotes regarding prostate cancer screening: n=436 in newspapers and television news. Results Seven rhetorical frames were identified. 86% of all quotes framed prostate screening and its outcomes as desirable, associating PSA testing as being consonant with other early-detection cancer-control messages. Adverse surgical sequelae to screening were often minimized, scientific progress highlighted and gender equity appeals appropriated. Those questioning screening were vilified, with epidemiology being framed as an inferior form of knowledge than clinical experience. Conclusions Australian men are exposed to unbalanced and often non-evidence-based appeals to seek PSA testing. There is a disturbing lack of effort to redress this imbalance. PMID:18048709

  6. Integrated remotely sensed datasets for disaster management

    NASA Astrophysics Data System (ADS)

    McCarthy, Timothy; Farrell, Ronan; Curtis, Andrew; Fotheringham, A. Stewart

    2008-10-01

    Video imagery can be acquired from aerial, terrestrial and marine based platforms and has been exploited for a range of remote sensing applications over the past two decades. Examples include coastal surveys using aerial video, routecorridor infrastructures surveys using vehicle mounted video cameras, aerial surveys over forestry and agriculture, underwater habitat mapping and disaster management. Many of these video systems are based on interlaced, television standards such as North America's NTSC and European SECAM and PAL television systems that are then recorded using various video formats. This technology has recently being employed as a front-line, remote sensing technology for damage assessment post-disaster. This paper traces the development of spatial video as a remote sensing tool from the early 1980s to the present day. The background to a new spatial-video research initiative based at National University of Ireland, Maynooth, (NUIM) is described. New improvements are proposed and include; low-cost encoders, easy to use software decoders, timing issues and interoperability. These developments will enable specialists and non-specialists collect, process and integrate these datasets within minimal support. This integrated approach will enable decision makers to access relevant remotely sensed datasets quickly and so, carry out rapid damage assessment during and post-disaster.

  7. Infrared and visible image fusion based on total variation and augmented Lagrangian.

    PubMed

    Guo, Hanqi; Ma, Yong; Mei, Xiaoguang; Ma, Jiayi

    2017-11-01

    This paper proposes a new algorithm for infrared and visible image fusion based on gradient transfer that achieves fusion by preserving the intensity of the infrared image and then transferring gradients in the corresponding visible one to the result. The gradient transfer suffers from the problems of low dynamic range and detail loss because it ignores the intensity from the visible image. The new algorithm solves these problems by providing additive intensity from the visible image to balance the intensity between the infrared image and the visible one. It formulates the fusion task as an l 1 -l 1 -TV minimization problem and then employs variable splitting and augmented Lagrangian to convert the unconstrained problem to a constrained one that can be solved in the framework of alternating the multiplier direction method. Experiments demonstrate that the new algorithm achieves better fusion results with a high computation efficiency in both qualitative and quantitative tests than gradient transfer and most state-of-the-art methods.

  8. Spectral CT Reconstruction with Image Sparsity and Spectral Mean

    PubMed Central

    Zhang, Yi; Xi, Yan; Yang, Qingsong; Cong, Wenxiang; Zhou, Jiliu

    2017-01-01

    Photon-counting detectors can acquire x-ray intensity data in different energy bins. The signal to noise ratio of resultant raw data in each energy bin is generally low due to the narrow bin width and quantum noise. To address this problem, here we propose an image reconstruction approach for spectral CT to simultaneously reconstructs x-ray attenuation coefficients in all the energy bins. Because the measured spectral data are highly correlated among the x-ray energy bins, the intra-image sparsity and inter-image similarity are important prior acknowledge for image reconstruction. Inspired by this observation, the total variation (TV) and spectral mean (SM) measures are combined to improve the quality of reconstructed images. For this purpose, a linear mapping function is used to minimalize image differences between energy bins. The split Bregman technique is applied to perform image reconstruction. Our numerical and experimental results show that the proposed algorithms outperform competing iterative algorithms in this context. PMID:29034267

  9. Content Themes of Alcohol Advertising in U.S. Television-Latent Class Analysis.

    PubMed

    Morgenstern, Matthis; Schoeppe, Franziska; Campbell, Julie; Braam, Marloes W G; Stoolmiller, Michael; Sargent, James D

    2015-09-01

    There is little alcohol research that reports on the thematic contents of contemporary alcohol advertisements in U.S. television. Studies of alcohol ads from 2 decades ago did not identify "Partying" as a social theme. Aim of this study was to describe and classify alcohol advertisements aired in national television in terms of contents, airing times, and channel placements and to identify different marketing strategies of alcohol brands. Content analysis of all ads from the top 20 U.S. beer and spirit brands aired between July 2009 and June 2011. These were 581 unique alcohol ads accounting for 272,828 (78%) national television airings. Ads were coded according to predefined definitions of 13 content areas. A latent class analysis (LCA) was conducted to define content cluster themes and determine alcoholic brands that were more likely to exploit these themes. About half of the advertisements (46%) were aired between 3 am and 8 pm, and the majority were placed either in Entertainment (40%) and Sports (38%) channels. Beer ads comprised 64% of the sample, with significant variation in airing times and channels between types of products and brands. LCA revealed 5 content classes that exploited the "Partying," "Quality," "Sports," "Manly," and "Relax" themes. The partying class, indicative of ad messages surrounding partying, love, and sex, was the dominant theme comprising 42% of all advertisements. Ads for alcopops, flavored spirits, and liqueur were more likely to belong to the party class, but there were also some beer brands (Corona, Heineken) where more than 67% of ads exploited this theme. This is the first analysis to identify a partying theme to contemporary alcohol advertising. Future analyses can now determine whether exposure to that or other themes predicts alcohol misuse among youth audiences. Copyright © 2015 by the Research Society on Alcoholism.

  10. Promoting calls to a quitline: quantifying the influence of message theme, strong negative emotions and graphic images in television advertisements.

    PubMed

    Farrelly, Matthew C; Davis, Kevin C; Nonnemaker, James M; Kamyab, Kian; Jackson, Christine

    2011-07-01

    To understand the relative effectiveness of television advertisements that differ in their thematic focus and portrayals of negative emotions and/or graphic images in promoting calls to a smokers' quitline. Regression analysis is used to explain variation in quarterly media market-level per smoker calls to the New York State Smokers' Quitline from 2001 to 2009. The primary independent variable is quarterly market-level delivery of television advertisements measured by target audience rating points (TARPs). Advertisements were characterised by their overall objective--promoting cessation, highlighting the dangers of secondhand smoke (SHS) or other--and by their portrayals of strong negative emotions and graphic images. Per smoker call volume is positively correlated with total TARPs (p<0.001), and cessation advertisements are more effective than SHS advertisements in promoting quitline call volume. Advertisements with graphic images only or neither strong negative emotions nor graphic images are associated with higher call volume with similar effect sizes. Call volume was not significantly associated with the number of TARPs for advertisements with strong negative emotions only (p=0.71) or with both graphic images and strong emotions (p=0.09). Exposure to television advertisements is strongly associated with quitline call volume, and both cessation and SHS advertisements can be effective. The use of strong negative emotions in advertisements may be effective in promoting smoking cessation in the population but does not appear to influence quitline call volume. Further research is needed to understand the role of negative emotions in promoting calls to quitlines and cessation more broadly among the majority of smokers who do not call quitlines.

  11. Depictions of substance use in reality television: a content analysis of The Osbournes.

    PubMed

    Blair, Nicole A; Yue, So Kuen; Singh, Ranbir; Bernhardt, Jay M

    2005-12-24

    To determine the source and slant of messages in a reality television programme that may promote or inhibit health related or risky behaviours. Coding visual and verbal references to alcohol, tobacco, and other drug (ATOD) use in The Osbournes. Three reviewers watched all 10 episodes of the first season and coded incidents of substance use according to the substance used (alcohol, tobacco, or drugs), the way use was portrayed (visually or verbally), the source of the message (the character in the show involved in the incident), and the slant of the incident (endorsement or rejection). The variation in number of messages in an average episode, the slant of messages, and message source. The average number of messages per episode was 9.1 (range 2-17). Most drug use messages (15, 54%) implied rejection of drugs, but most alcohol messages (30, 64%) and tobacco messages (12, 75%) implied endorsements for using these substances. Most rejections (34, 94%) were conveyed verbally, but most endorsements (36, 65%) were conveyed visually. Messages varied in frequency and slant by source. The reality television show analysed in this study contains numerous messages on substance use that imply both rejection and endorsement of use. The juxtaposition of verbal rejection messages and visual endorsement messages, and the depiction of contradictory messages about substance use from show characters, may send mixed messages to viewers about substance use.

  12. Form cues and content difficulty as determinants of children's cognitive processing of televised educational messages.

    PubMed

    Campbell, T A; Wright, J C; Huston, A C

    1987-06-01

    An experiment was designed to assess the effects of formal production features and content difficulty on children's processing of televised messages about nutrition. Messages with identical content (the same script and visual shot sequence) were made in two forms: child program forms (animated film, second-person address, and character voice narration with sprightly music) and adult program forms (live photography, third-person address, and adult male narration with sedate background music). For each form, messages were made at three levels of content difficulty. Easier versions were longer, more redundant, and used simpler language; difficult versions presented information more quickly with less redundancy and more abstract language. Regardless of form or difficulty level, each set of bits presented the same basic information. Kindergarten children (N = 120) were assigned to view three different bits of the same form type and difficulty embedded in a miniprogram. Visual attention to child forms was significantly greater than to adult forms; free and cued recall scores were also higher for child than for adult forms. Although all recall and recognition scores were best for easy versions and worst for difficult versions, attention showed only minor variation as a function of content difficulty. Results are interpreted to indicate that formal production features, independently of content, influence the effort and level of processing that children use to understand televised educational messages.

  13. Biological and environmental determinants of childhood obesity.

    PubMed

    Blass, Elliott M

    2003-01-01

    Childhood obesity reflects the confluence of three factors that minimize attention to internal physiologic satiety signals: the release of central opioids through ingestion of sweets and fats, which induces a preference for such foods; the phylogenetic quality of extending meals in response to environmental demands, as in work schedules, or through finding patches of agreeable food that are safe to consume (this is exacerbated in impoverished children, whose activity is limited); the determination of food preference through social interactions renders feeding systems open to external influences such as mass marketing and television advertising. Alternative feeding modes are presented based on studies of childhood food preferences and how children may be influenced to choose more balanced and healthier diets.

  14. An l1-TV algorithm for deconvolution with salt and pepper noise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wohlberg, Brendt; Rodriguez, Paul

    2008-01-01

    There has recently been considerable interest in applying Total Variation with an {ell}{sup 1} data fidelity term to the denoising of images subject to salt and pepper noise, but the extension of this formulation to more general problems, such as deconvolution, has received little attention, most probably because most efficient algorithms for {ell}{sup 1}-TV denoising can not handle more general inverse problems. We apply the Iteratively Reweighted Norm algorithm to this problem, and compare performance with an alternative algorithm based on the Mumford-Shah functional.

  15. Precision Measurement of the Proton Flux in Primary Cosmic Rays from Rigidity 1 GV to 1.8 TV with the Alpha Magnetic Spectrometer on the International Space Station

    NASA Astrophysics Data System (ADS)

    Aguilar, M.; Aisa, D.; Alpat, B.; Alvino, A.; Ambrosi, G.; Andeen, K.; Arruda, L.; Attig, N.; Azzarello, P.; Bachlechner, A.; Barao, F.; Barrau, A.; Barrin, L.; Bartoloni, A.; Basara, L.; Battarbee, M.; Battiston, R.; Bazo, J.; Becker, U.; Behlmann, M.; Beischer, B.; Berdugo, J.; Bertucci, B.; Bigongiari, G.; Bindi, V.; Bizzaglia, S.; Bizzarri, M.; Boella, G.; de Boer, W.; Bollweg, K.; Bonnivard, V.; Borgia, B.; Borsini, S.; Boschini, M. J.; Bourquin, M.; Burger, J.; Cadoux, F.; Cai, X. D.; Capell, M.; Caroff, S.; Casaus, J.; Cascioli, V.; Castellini, G.; Cernuda, I.; Cerreta, D.; Cervelli, F.; Chae, M. J.; Chang, Y. H.; Chen, A. I.; Chen, H.; Cheng, G. M.; Chen, H. S.; Cheng, L.; Chou, H. Y.; Choumilov, E.; Choutko, V.; Chung, C. H.; Clark, C.; Clavero, R.; Coignet, G.; Consolandi, C.; Contin, A.; Corti, C.; Gil, E. Cortina; Coste, B.; Creus, W.; Crispoltoni, M.; Cui, Z.; Dai, Y. M.; Delgado, C.; Della Torre, S.; Demirköz, M. B.; Derome, L.; Di Falco, S.; Di Masso, L.; Dimiccoli, F.; Díaz, C.; von Doetinchem, P.; Donnini, F.; Du, W. J.; Duranti, M.; D'Urso, D.; Eline, A.; Eppling, F. J.; Eronen, T.; Fan, Y. Y.; Farnesini, L.; Feng, J.; Fiandrini, E.; Fiasson, A.; Finch, E.; Fisher, P.; Galaktionov, Y.; Gallucci, G.; García, B.; García-López, R.; Gargiulo, C.; Gast, H.; Gebauer, I.; Gervasi, M.; Ghelfi, A.; Gillard, W.; Giovacchini, F.; Goglov, P.; Gong, J.; Goy, C.; Grabski, V.; Grandi, D.; Graziani, M.; Guandalini, C.; Guerri, I.; Guo, K. H.; Haas, D.; Habiby, M.; Haino, S.; Han, K. C.; He, Z. H.; Heil, M.; Hoffman, J.; Hsieh, T. H.; Huang, Z. C.; Huh, C.; Incagli, M.; Ionica, M.; Jang, W. Y.; Jinchi, H.; Kanishev, K.; Kim, G. N.; Kim, K. S.; Kirn, Th.; Kossakowski, R.; Kounina, O.; Kounine, A.; Koutsenko, V.; Krafczyk, M. S.; La Vacca, G.; Laudi, E.; Laurenti, G.; Lazzizzera, I.; Lebedev, A.; Lee, H. T.; Lee, S. C.; Leluc, C.; Levi, G.; Li, H. L.; Li, J. Q.; Li, Q.; Li, Q.; Li, T. X.; Li, W.; Li, Y.; Li, Z. H.; Li, Z. Y.; Lim, S.; Lin, C. H.; Lipari, P.; Lippert, T.; Liu, D.; Liu, H.; Lolli, M.; Lomtadze, T.; Lu, M. J.; Lu, S. Q.; Lu, Y. S.; Luebelsmeyer, K.; Luo, J. Z.; Lv, S. S.; Majka, R.; Mañá, C.; Marín, J.; Martin, T.; Martínez, G.; Masi, N.; Maurin, D.; Menchaca-Rocha, A.; Meng, Q.; Mo, D. C.; Morescalchi, L.; Mott, P.; Müller, M.; Ni, J. Q.; Nikonov, N.; Nozzoli, F.; Nunes, P.; Obermeier, A.; Oliva, A.; Orcinha, M.; Palmonari, F.; Palomares, C.; Paniccia, M.; Papi, A.; Pauluzzi, M.; Pedreschi, E.; Pensotti, S.; Pereira, R.; Picot-Clemente, N.; Pilo, F.; Piluso, A.; Pizzolotto, C.; Plyaskin, V.; Pohl, M.; Poireau, V.; Postaci, E.; Putze, A.; Quadrani, L.; Qi, X. M.; Qin, X.; Qu, Z. Y.; Räihä, T.; Rancoita, P. G.; Rapin, D.; Ricol, J. S.; Rodríguez, I.; Rosier-Lees, S.; Rozhkov, A.; Rozza, D.; Sagdeev, R.; Sandweiss, J.; Saouter, P.; Sbarra, C.; Schael, S.; Schmidt, S. M.; von Dratzig, A. Schulz; Schwering, G.; Scolieri, G.; Seo, E. S.; Shan, B. S.; Shan, Y. H.; Shi, J. Y.; Shi, X. Y.; Shi, Y. M.; Siedenburg, T.; Son, D.; Spada, F.; Spinella, F.; Sun, W.; Sun, W. H.; Tacconi, M.; Tang, C. P.; Tang, X. W.; Tang, Z. C.; Tao, L.; Tescaro, D.; Ting, Samuel C. C.; Ting, S. M.; Tomassetti, N.; Torsti, J.; Türkoǧlu, C.; Urban, T.; Vagelli, V.; Valente, E.; Vannini, C.; Valtonen, E.; Vaurynovich, S.; Vecchi, M.; Velasco, M.; Vialle, J. P.; Vitale, V.; Vitillo, S.; Wang, L. Q.; Wang, N. H.; Wang, Q. L.; Wang, R. S.; Wang, X.; Wang, Z. X.; Weng, Z. L.; Whitman, K.; Wienkenhöver, J.; Wu, H.; Wu, X.; Xia, X.; Xie, M.; Xie, S.; Xiong, R. Q.; Xin, G. M.; Xu, N. S.; Xu, W.; Yan, Q.; Yang, J.; Yang, M.; Ye, Q. H.; Yi, H.; Yu, Y. J.; Yu, Z. Q.; Zeissler, S.; Zhang, J. H.; Zhang, M. T.; Zhang, X. B.; Zhang, Z.; Zheng, Z. M.; Zhuang, H. L.; Zhukov, V.; Zichichi, A.; Zimmermann, N.; Zuccon, P.; Zurbach, C.; AMS Collaboration

    2015-05-01

    A precise measurement of the proton flux in primary cosmic rays with rigidity (momentum/charge) from 1 GV to 1.8 TV is presented based on 300 million events. Knowledge of the rigidity dependence of the proton flux is important in understanding the origin, acceleration, and propagation of cosmic rays. We present the detailed variation with rigidity of the flux spectral index for the first time. The spectral index progressively hardens at high rigidities.

  16. Do Young People Ever Sit Still? Variations in Accelerometer Counts, Muscle Activity and Heart Rate across Various Sedentary Activities in Youth.

    PubMed

    van Ekris, Evi; Chinapaw, Mai J M; Rotteveel, Joost; Altenburg, Teatske M

    2018-05-17

    Evidence of adverse health effects of TV viewing is stronger than for overall sedentary behaviour in youth. One explanation may be that TV viewing involves less body movement than other sedentary activities. Variations in body movement across sedentary activities are currently unknown, as are age differences in such variations. This study examined body movement differences across various sedentary activities in children and adolescents, assessed by hip-, thigh- and wrist-worn accelerometers, muscle activity and heart rate. Body movement differences between sedentary activities and standing were also examined. Fifty-three children (aged 10⁻12 years) and 37 adolescents (aged 16⁻18 years) performed seven different sedentary activities, a standing activity, and a dancing activity (as a control activity) in a controlled setting. Each activity lasted 10 minutes. Participants wore an Actigraph on their hip and both wrists, an activPAL on their thigh and a heart rate monitor. The muscle activity of weight-bearing leg muscles was measured in a subgroup ( n = 38) by surface electromyography. Variations in body movement across activities were examined using general estimation equations analysis. Children showed significantly more body movement during sedentary activities and standing than adolescents. In both age groups, screen-based sedentary activities involved less body movement than non-screen-based sedentary activities. This may explain the stronger evidence for detrimental health effects of TV viewing while evidence for child sedentary behaviour in general is inconsistent. Differences in body movement during standing and sedentary activities were relatively small. Future research should examine the potential health effects of differences in body movement between screen-based versus non-screen based and standing versus sedentary activities.

  17. [Analysis of TV food advertising in the context of recommendations by the Food Guide for the Brazilian Population].

    PubMed

    Maia, Emanuella Gomes; Costa, Bruna Vieira de Lima; Coelho, Francielly de Souza; Guimarães, Julia Soares; Fortaleza, Rafaela Garcia; Claro, Rafael Moreira

    2017-05-18

    This study aimed to analyze TV food advertising in Brazil based on the recommendations of the Food Guide for the Brazilian Population, 2014. Programming from the four most popular TV channels was recorded on two non-consecutive days in January 2014. The commercials were categorized in (i) foods and beverages, (ii) restaurants, and (iii) non-food services, goods, and products, with those in the first category subdivided according to recommendations in the food guide. The commercials' categories were described by means of their frequency (and 95% confidence interval), for all the records and according to the day of the week. Of the 2,732 commercials that were identified, food and beverage advertising was the third largest category, with 10.2% of the total. In this category, ultra-processed foods accounted for 60.7% of the commercials, while fresh or minimally processed foods at around 7%. The findings run counter to the guide's recommendations, reinforcing the importance of measures to regulate food advertising in Brazil.

  18. Total variation superiorized conjugate gradient method for image reconstruction

    NASA Astrophysics Data System (ADS)

    Zibetti, Marcelo V. W.; Lin, Chuan; Herman, Gabor T.

    2018-03-01

    The conjugate gradient (CG) method is commonly used for the relatively-rapid solution of least squares problems. In image reconstruction, the problem can be ill-posed and also contaminated by noise; due to this, approaches such as regularization should be utilized. Total variation (TV) is a useful regularization penalty, frequently utilized in image reconstruction for generating images with sharp edges. When a non-quadratic norm is selected for regularization, as is the case for TV, then it is no longer possible to use CG. Non-linear CG is an alternative, but it does not share the efficiency that CG shows with least squares and methods such as fast iterative shrinkage-thresholding algorithms (FISTA) are preferred for problems with TV norm. A different approach to including prior information is superiorization. In this paper it is shown that the conjugate gradient method can be superiorized. Five different CG variants are proposed, including preconditioned CG. The CG methods superiorized by the total variation norm are presented and their performance in image reconstruction is demonstrated. It is illustrated that some of the proposed variants of the superiorized CG method can produce reconstructions of superior quality to those produced by FISTA and in less computational time, due to the speed of the original CG for least squares problems. In the Appendix we examine the behavior of one of the superiorized CG methods (we call it S-CG); one of its input parameters is a positive number ɛ. It is proved that, for any given ɛ that is greater than the half-squared-residual for the least squares solution, S-CG terminates in a finite number of steps with an output for which the half-squared-residual is less than or equal to ɛ. Importantly, it is also the case that the output will have a lower value of TV than what would be provided by unsuperiorized CG for the same value ɛ of the half-squared residual.

  19. Media, product differences and seasonality in alcohol advertising in 1997.

    PubMed

    Snyder, L B; Milici, F F; Mitchell, E W; Proctor, D C

    2000-11-01

    To spell out recent events related to the alcohol advertising controversy and to describe the extent of alcohol advertising for 1 year, the media favored for advertising different types of alcoholic beverages and seasonal variation in advertising patterns. Monthly advertising data for 1997 were obtained from a variety of sources, including a commercial media monitoring service, a watchdog group, and trade and business press. Media examined were national and local television, radio, magazines, newspapers and billboards. Alcohol advertising expenditures were greatest in the late spring/early summer and during the holiday season. Television received the preponderance of alcohol advertising dollars for beer, wine, wine coolers and premixed drinks. Distilled spirits relied mostly on magazine advertising. Beer was the most heavily advertised product. More than half of televised beer ads aired on Saturday or Sunday afternoon during sporting events. There were more radio and TV ads for premixed low-alcohol beverages--some of which contain distilled spirits and many using brand names of distilled spirits--than for higher proof distilled spirits. Public health officials can use the results to plan the month and media in which to launch messages against alcohol misuse, to directly counter pro-alcohol messages in advertising. They should monitor consumption and advertising of premixed beverages. Those concerned with the debate on alcohol advertising should note the access children have to beer ads when these ads are aired during weekend daytime sporting events, and that beer remains the greatest advertised beverage, despite the 1996 lifting of the broadcast advertising ban on distilled spirits.

  20. Experimental investigation of passive thermodynamic vent system (TVS) with liquid nitrogen

    NASA Astrophysics Data System (ADS)

    Bae, Junhyuk; Yoo, Junghyun; Jin, Lingxue; Jeong, Sangkwon

    2018-01-01

    Thermodynamic vent system (TVS) is an attractive technology to maintain an allowable pressure level of a cryogenic propellant storage in a spacecraft under micro-gravity condition. There are two types of TVS; active or passive. In this paper, the passive TVS which does not utilize a cryogenic liquid circulation pump is experimentally investigated with liquid nitrogen and numerically analyzed by thermodynamic and heat transfer model. A cylindrical copper tank, which is 198 mm in inner diameter and 216 mm in height, is utilized to suppress a thermal-stratification effect of inside cryogenic fluid. A coil heat exchanger, which is 3 m in length and 6.35 mm in outer diameter, and a fixed size orifice of which diameter is 0.4 mm are fabricated to remove heat from the stored fluid to the vented flow. Each vent process is initiated at 140 kPa and ended at 120 kPa with liquid nitrogen fill levels which are 30%, 50% and 70%, respectively. In the numerical model, the fluid in the tank is assumed to be homogeneous saturated liquid-vapor. Mass and energy balance equations with heat transfer conditions suggested in this research are considered to calculate the transient pressure variation in the tank and the amount of heat transfer across the heat exchanger. We achieve the average heat rejection rate of more than 9 W by TVS and conclude that the passive TVS operates satisfactorily. In addition, the prediction model is verified by experimental results. Although the model has limitation in providing accurate results, it can surely predict the tendency of pressure and temperature changes in the tank. Furthermore, the model can suggest how we can improve the heat exchanger design to enhance an overall efficiency of passive TVS. Moreover, the performance of passive TVS is compared with other cryogenic vent systems (direct vent system and active TVS) by suggested performance indicator.

  1. Dynamic re-weighted total variation technique and statistic Iterative reconstruction method for x-ray CT metal artifact reduction

    NASA Astrophysics Data System (ADS)

    Peng, Chengtao; Qiu, Bensheng; Zhang, Cheng; Ma, Changyu; Yuan, Gang; Li, Ming

    2017-07-01

    Over the years, the X-ray computed tomography (CT) has been successfully used in clinical diagnosis. However, when the body of the patient to be examined contains metal objects, the image reconstructed would be polluted by severe metal artifacts, which affect the doctor's diagnosis of disease. In this work, we proposed a dynamic re-weighted total variation (DRWTV) technique combined with the statistic iterative reconstruction (SIR) method to reduce the artifacts. The DRWTV method is based on the total variation (TV) and re-weighted total variation (RWTV) techniques, but it provides a sparser representation than TV and protects the tissue details better than RWTV. Besides, the DRWTV can suppress the artifacts and noise, and the SIR convergence speed is also accelerated. The performance of the algorithm is tested on both simulated phantom dataset and clinical dataset, which are the teeth phantom with two metal implants and the skull with three metal implants, respectively. The proposed algorithm (SIR-DRWTV) is compared with two traditional iterative algorithms, which are SIR and SIR constrained by RWTV regulation (SIR-RWTV). The results show that the proposed algorithm has the best performance in reducing metal artifacts and protecting tissue details.

  2. A frequency and content analysis of alcohol advertising on Brazilian television.

    PubMed

    Pinsky, I; Silva, M T

    1999-05-01

    Two studies were conducted with the objective of analyzing the frequency and content of alcoholic beverage advertising on Brazilian television. Study 1 presents a frequency analysis based on 84 hours of TV monitoring in which 1,640 commercials and 243 vignettes were recorded between 8:00 PM and 11:00 PM on the two main stations. Study 2 presents a content analysis of 139 alcoholic and 51 nonalcoholic beverage commercials aired in 1992-93, as evaluated by three trained judges. Study 1 showed the relative frequency of alcoholic beverage commercials (4.6%) to be higher than the frequency of other products such as cigarettes, nonalcoholic beverages and medicines, and lower than that of foods and various other items. Frequency of alcoholic "vignettes" (26.6%) was higher than the frequency of all the other product categories. Frequency data were closely matched by marketing investment data for the period. In Study 2, the most frequent themes and appeals present in alcohol commercials were relaxation, national symbolism, conformity, camaraderie and humor. Human models were present in most ads. Product-related themes such as information, quality or tradition were virtually absent, as were messages to drink moderately. However, 7.2% of the alcohol commercials displayed appeals promoting abusive drinking. The results seem to reflect the minimal regulation of alcohol advertising in Brazil, and a joint effort by health planners, educators, legislators, alcohol industries and advertising agencies is recommended as a necessary step to reduce alcoholic beverage problems in Brazilian society.

  3. View generation for 3D-TV using image reconstruction from irregularly spaced samples

    NASA Astrophysics Data System (ADS)

    Vázquez, Carlos

    2007-02-01

    Three-dimensional television (3D-TV) will become the next big step in the development of advanced TV systems. One of the major challenges for the deployment of 3D-TV systems is the diversity of display technologies and the high cost of capturing multi-view content. Depth image-based rendering (DIBR) has been identified as a key technology for the generation of new views for stereoscopic and multi-view displays from a small number of views captured and transmitted. We propose a disparity compensation method for DIBR that does not require spatial interpolation of the disparity map. We use a forward-mapping disparity compensation with real precision. The proposed method deals with the irregularly sampled image resulting from this disparity compensation process by applying a re-sampling algorithm based on a bi-cubic spline function space that produces smooth images. The fact that no approximation is made on the position of the samples implies that geometrical distortions in the final images due to approximations in sample positions are minimized. We also paid attention to the occlusion problem. Our algorithm detects the occluded regions in the newly generated images and uses simple depth-aware inpainting techniques to fill the gaps created by newly exposed areas. We tested the proposed method in the context of generation of views needed for viewing on SynthaGram TM auto-stereoscopic displays. We used as input either a 2D image plus a depth map or a stereoscopic pair with the associated disparity map. Our results show that this technique provides high quality images to be viewed on different display technologies such as stereoscopic viewing with shutter glasses (two views) and lenticular auto-stereoscopic displays (nine views).

  4. Managing Risks? Early Warning Systems for Climate Change

    NASA Astrophysics Data System (ADS)

    Sitati, A. M.; Zommers, Z. A.; Habilov, M.

    2014-12-01

    Early warning systems are a tool with which to minimize risks posed by climate related hazards. Although great strides have been made in developing early warning systems most deal with one hazard, only provide short-term warnings and do not reach the most vulnerable. This presentation will review research results of the United Nations Environment Programme's CLIM-WARN project. The project seeks to identify how governments can better communicate risks by designing multi-hazard early warning systems that deliver actionable warnings across timescales. Household surveys and focus group discussions were conducted in 36 communities in Kenya, Ghana and Burkina Faso in order to identify relevant climate related hazards, current response strategies and early warning needs. Preliminary results show significant variability in both risks and needs within and between countries. For instance, floods are more frequent in rural western parts of Kenya. Droughts are frequent in the north while populations in urban areas face a range of hazards - floods, droughts, disease outbreaks - that sometimes occur simultaneously. The majority of the rural population, especially women, the disabled and the elderly, do not have access to modern media such as radio, television, or internet. While 55% of rural populace never watches television, 64% of urban respondents watch television on a daily basis. Communities have different concepts of how to design warning systems. It will be a challenge for national governments to create systems that accommodate such diversity yet provide standard quality of service to all. There is a need for flexible and forward-looking early warning systems that deliver broader information about risks. Information disseminated through the system could not only include details of hazards, but also long-term adaptation options, general education, and health information, thus increasingly both capabilities and response options.

  5. Creating demand for prescription drugs: a content analysis of television direct-to-consumer advertising.

    PubMed

    Frosch, Dominick L; Krueger, Patrick M; Hornik, Robert C; Cronholm, Peter F; Barg, Frances K

    2007-01-01

    American television viewers see as many as 16 hours of prescription drug advertisements (ads) each year, yet no research has examined how television ads attempt to influence consumers. This information is important, because ads may not meet their educational potential, possibly prompting consumers to request prescriptions that are clinically inappropriate or more expensive than equally effective alternatives. We coded ads shown during evening news and prime time hours for factual claims they make about the target condition, how they attempt to appeal to consumers, and how they portray the medication and lifestyle behaviors in the lives of ad characters. Most ads (82%) made some factual claims and made rational arguments (86%) for product use, but few described condition causes (26%), risk factors (26%), or prevalence (25%). Emotional appeals were almost universal (95%). No ads mentioned lifestyle change as an alternative to products, though some (19%) portrayed it as an adjunct to medication. Some ads (18%) portrayed lifestyle changes as insufficient for controlling a condition. The ads often framed medication use in terms of losing (58%) and regaining control (85%) over some aspect of life and as engendering social approval (78%). Products were frequently (58%) portrayed as a medical breakthrough. Despite claims that ads serve an educational purpose, they provide limited information about the causes of a disease or who may be at risk; they show characters that have lost control over their social, emotional, or physical lives without the medication; and they minimize the value of health promotion through lifestyle changes. The ads have limited educational value and may oversell the benefits of drugs in ways that might conflict with promoting population health.

  6. Creating Demand for Prescription Drugs: A Content Analysis of Television Direct-to-Consumer Advertising

    PubMed Central

    Frosch, Dominick L.; Krueger, Patrick M.; Hornik, Robert C.; Cronholm, Peter F.; Barg, Frances K.

    2007-01-01

    PURPOSE American television viewers see as many as 16 hours of prescription drug advertisements (ads) each year, yet no research has examined how television ads attempt to influence consumers. This information is important, because ads may not meet their educational potential, possibly prompting consumers to request prescriptions that are clinically inappropriate or more expensive than equally effective alternatives. METHODS We coded ads shown during evening news and prime time hours for factual claims they make about the target condition, how they attempt to appeal to consumers, and how they portray the medication and lifestyle behaviors in the lives of ad characters. RESULTS Most ads (82%) made some factual claims and made rational arguments (86%) for product use, but few described condition causes (26%), risk factors (26%), or prevalence (25%). Emotional appeals were almost universal (95%). No ads mentioned lifestyle change as an alternative to products, though some (19%) portrayed it as an adjunct to medication. Some ads (18%) portrayed lifestyle changes as insufficient for controlling a condition. The ads often framed medication use in terms of losing (58%) and regaining control (85%) over some aspect of life and as engendering social approval (78%). Products were frequently (58%) portrayed as a medical breakthrough. CONCLUSIONS Despite claims that ads serve an educational purpose, they provide limited information about the causes of a disease or who may be at risk; they show characters that have lost control over their social, emotional, or physical lives without the medication; and they minimize the value of health promotion through lifestyle changes. The ads have limited educational value and may oversell the benefits of drugs in ways that might conflict with promoting population health. PMID:17261859

  7. Estimation of Noise Properties for TV-regularized Image Reconstruction in Computed Tomography

    PubMed Central

    Sánchez, Adrian A.

    2016-01-01

    A method for predicting the image covariance resulting from total-variation-penalized iterative image reconstruction (TV-penalized IIR) is presented and demonstrated in a variety of contexts. The method is validated against the sample covariance from statistical noise realizations for a small image using a variety of comparison metrics. Potential applications for the covariance approximation include investigation of image properties such as object- and signal-dependence of noise, and noise stationarity. These applications are demonstrated, along with the construction of image pixel variance maps for two-dimensional 128 × 128 pixel images. Methods for extending the proposed covariance approximation to larger images and improving computational efficiency are discussed. Future work will apply the developed methodology to the construction of task-based image quality metrics such as the Hotelling observer detectability for TV-based IIR. PMID:26308968

  8. Depth inpainting by tensor voting.

    PubMed

    Kulkarni, Mandar; Rajagopalan, Ambasamudram N

    2013-06-01

    Depth maps captured by range scanning devices or by using optical cameras often suffer from missing regions due to occlusions, reflectivity, limited scanning area, sensor imperfections, etc. In this paper, we propose a fast and reliable algorithm for depth map inpainting using the tensor voting (TV) framework. For less complex missing regions, local edge and depth information is utilized for synthesizing missing values. The depth variations are modeled by local planes using 3D TV, and missing values are estimated using plane equations. For large and complex missing regions, we collect and evaluate depth estimates from self-similar (training) datasets. We align the depth maps of the training set with the target (defective) depth map and evaluate the goodness of depth estimates among candidate values using 3D TV. We demonstrate the effectiveness of the proposed approaches on real as well as synthetic data.

  9. Estimation of noise properties for TV-regularized image reconstruction in computed tomography.

    PubMed

    Sánchez, Adrian A

    2015-09-21

    A method for predicting the image covariance resulting from total-variation-penalized iterative image reconstruction (TV-penalized IIR) is presented and demonstrated in a variety of contexts. The method is validated against the sample covariance from statistical noise realizations for a small image using a variety of comparison metrics. Potential applications for the covariance approximation include investigation of image properties such as object- and signal-dependence of noise, and noise stationarity. These applications are demonstrated, along with the construction of image pixel variance maps for two-dimensional 128 × 128 pixel images. Methods for extending the proposed covariance approximation to larger images and improving computational efficiency are discussed. Future work will apply the developed methodology to the construction of task-based image quality metrics such as the Hotelling observer detectability for TV-based IIR.

  10. Estimation of noise properties for TV-regularized image reconstruction in computed tomography

    NASA Astrophysics Data System (ADS)

    Sánchez, Adrian A.

    2015-09-01

    A method for predicting the image covariance resulting from total-variation-penalized iterative image reconstruction (TV-penalized IIR) is presented and demonstrated in a variety of contexts. The method is validated against the sample covariance from statistical noise realizations for a small image using a variety of comparison metrics. Potential applications for the covariance approximation include investigation of image properties such as object- and signal-dependence of noise, and noise stationarity. These applications are demonstrated, along with the construction of image pixel variance maps for two-dimensional 128× 128 pixel images. Methods for extending the proposed covariance approximation to larger images and improving computational efficiency are discussed. Future work will apply the developed methodology to the construction of task-based image quality metrics such as the Hotelling observer detectability for TV-based IIR.

  11. Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Si; Xu, Yuesheng, E-mail: yxu06@syr.edu; Zhang, Jiahan

    Purpose: The authors have recently developed a preconditioned alternating projection algorithm (PAPA) with total variation (TV) regularizer for solving the penalized-likelihood optimization model for single-photon emission computed tomography (SPECT) reconstruction. This algorithm belongs to a novel class of fixed-point proximity methods. The goal of this work is to investigate how PAPA performs while dealing with realistic noisy SPECT data, to compare its performance with more conventional methods, and to address issues with TV artifacts by proposing a novel form of the algorithm invoking high-order TV regularization, denoted as HOTV-PAPA, which has been explored and studied extensively in the present work.more » Methods: Using Monte Carlo methods, the authors simulate noisy SPECT data from two water cylinders; one contains lumpy “warm” background and “hot” lesions of various sizes with Gaussian activity distribution, and the other is a reference cylinder without hot lesions. The authors study the performance of HOTV-PAPA and compare it with PAPA using first-order TV regularization (TV-PAPA), the Panin–Zeng–Gullberg one-step-late method with TV regularization (TV-OSL), and an expectation–maximization algorithm with Gaussian postfilter (GPF-EM). The authors select penalty-weights (hyperparameters) by qualitatively balancing the trade-off between resolution and image noise separately for TV-PAPA and TV-OSL. However, the authors arrived at the same penalty-weight value for both of them. The authors set the first penalty-weight in HOTV-PAPA equal to the optimal penalty-weight found for TV-PAPA. The second penalty-weight needed for HOTV-PAPA is tuned by balancing resolution and the severity of staircase artifacts. The authors adjust the Gaussian postfilter to approximately match the local point spread function of GPF-EM and HOTV-PAPA. The authors examine hot lesion detectability, study local spatial resolution, analyze background noise properties, estimate mean square errors (MSEs), and report the convergence speed and computation time. Results: HOTV-PAPA yields the best signal-to-noise ratio, followed by TV-PAPA and TV-OSL/GPF-EM. The local spatial resolution of HOTV-PAPA is somewhat worse than that of TV-PAPA and TV-OSL. Images reconstructed using HOTV-PAPA have the lowest local noise power spectrum (LNPS) amplitudes, followed by TV-PAPA, TV-OSL, and GPF-EM. The LNPS peak of GPF-EM is shifted toward higher spatial frequencies than those for the three other methods. The PAPA-type methods exhibit much lower ensemble noise, ensemble voxel variance, and image roughness. HOTV-PAPA performs best in these categories. Whereas images reconstructed using both TV-PAPA and TV-OSL are degraded by severe staircase artifacts; HOTV-PAPA substantially reduces such artifacts. It also converges faster than the other three methods and exhibits the lowest overall reconstruction error level, as measured by MSE. Conclusions: For high-noise simulated SPECT data, HOTV-PAPA outperforms TV-PAPA, GPF-EM, and TV-OSL in terms of hot lesion detectability, noise suppression, MSE, and computational efficiency. Unlike TV-PAPA and TV-OSL, HOTV-PAPA does not create sizable staircase artifacts. Moreover, HOTV-PAPA effectively suppresses noise, with only limited loss of local spatial resolution. Of the four methods, HOTV-PAPA shows the best lesion detectability, thanks to its superior noise suppression. HOTV-PAPA shows promise for clinically useful reconstructions of low-dose SPECT data.« less

  12. Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm

    PubMed Central

    Li, Si; Zhang, Jiahan; Krol, Andrzej; Schmidtlein, C. Ross; Vogelsang, Levon; Shen, Lixin; Lipson, Edward; Feiglin, David; Xu, Yuesheng

    2015-01-01

    Purpose: The authors have recently developed a preconditioned alternating projection algorithm (PAPA) with total variation (TV) regularizer for solving the penalized-likelihood optimization model for single-photon emission computed tomography (SPECT) reconstruction. This algorithm belongs to a novel class of fixed-point proximity methods. The goal of this work is to investigate how PAPA performs while dealing with realistic noisy SPECT data, to compare its performance with more conventional methods, and to address issues with TV artifacts by proposing a novel form of the algorithm invoking high-order TV regularization, denoted as HOTV-PAPA, which has been explored and studied extensively in the present work. Methods: Using Monte Carlo methods, the authors simulate noisy SPECT data from two water cylinders; one contains lumpy “warm” background and “hot” lesions of various sizes with Gaussian activity distribution, and the other is a reference cylinder without hot lesions. The authors study the performance of HOTV-PAPA and compare it with PAPA using first-order TV regularization (TV-PAPA), the Panin–Zeng–Gullberg one-step-late method with TV regularization (TV-OSL), and an expectation–maximization algorithm with Gaussian postfilter (GPF-EM). The authors select penalty-weights (hyperparameters) by qualitatively balancing the trade-off between resolution and image noise separately for TV-PAPA and TV-OSL. However, the authors arrived at the same penalty-weight value for both of them. The authors set the first penalty-weight in HOTV-PAPA equal to the optimal penalty-weight found for TV-PAPA. The second penalty-weight needed for HOTV-PAPA is tuned by balancing resolution and the severity of staircase artifacts. The authors adjust the Gaussian postfilter to approximately match the local point spread function of GPF-EM and HOTV-PAPA. The authors examine hot lesion detectability, study local spatial resolution, analyze background noise properties, estimate mean square errors (MSEs), and report the convergence speed and computation time. Results: HOTV-PAPA yields the best signal-to-noise ratio, followed by TV-PAPA and TV-OSL/GPF-EM. The local spatial resolution of HOTV-PAPA is somewhat worse than that of TV-PAPA and TV-OSL. Images reconstructed using HOTV-PAPA have the lowest local noise power spectrum (LNPS) amplitudes, followed by TV-PAPA, TV-OSL, and GPF-EM. The LNPS peak of GPF-EM is shifted toward higher spatial frequencies than those for the three other methods. The PAPA-type methods exhibit much lower ensemble noise, ensemble voxel variance, and image roughness. HOTV-PAPA performs best in these categories. Whereas images reconstructed using both TV-PAPA and TV-OSL are degraded by severe staircase artifacts; HOTV-PAPA substantially reduces such artifacts. It also converges faster than the other three methods and exhibits the lowest overall reconstruction error level, as measured by MSE. Conclusions: For high-noise simulated SPECT data, HOTV-PAPA outperforms TV-PAPA, GPF-EM, and TV-OSL in terms of hot lesion detectability, noise suppression, MSE, and computational efficiency. Unlike TV-PAPA and TV-OSL, HOTV-PAPA does not create sizable staircase artifacts. Moreover, HOTV-PAPA effectively suppresses noise, with only limited loss of local spatial resolution. Of the four methods, HOTV-PAPA shows the best lesion detectability, thanks to its superior noise suppression. HOTV-PAPA shows promise for clinically useful reconstructions of low-dose SPECT data. PMID:26233214

  13. Adversity, time, and well-being: A longitudinal analysis of time perspective in adulthood.

    PubMed

    Holman, E Alison; Silver, Roxane Cohen; Mogle, Jacqueline A; Scott, Stacey B

    2016-09-01

    Despite the prominence of time in influential aging theories and the ubiquity of stress across the life span, research addressing how time perspective (TP) and adversity are associated with well-being across adulthood is rare. Examining the role of TP in coping with life events over the life span would be best accomplished after large-scale population-based exposure to a specific event, with repeated assessments to examine within- and between-person differences over time. A national sample aged 18-91 years (N = 722, M = 49.4 years) was followed for 3 years after the September 11, 2001 (9/11) terrorist attacks. Respondents completed assessments of 9/11-related television (TV) exposure 9-21 days after the attacks, temporal disintegration 2 months post-9/11, and TP, ongoing stress, and well-being at 12, 24, and 36 months post-9/11. Results provided support for measurement invariance of TP across time and across age. Early 9/11-related TV exposure was significantly associated with greater temporal disintegration. Temporal disintegration and ongoing stress, in turn, were associated with between- and within-person variation in past TP. This effect was qualified by an age interaction that indicated a stronger relationship between ongoing stress and past TP for younger compared with older adults. Past and future TP were significantly and independently related to individual differences and within-person variation in psychological well-being, regardless of age. Future work should incorporate adversity as an important correlate of TP across adulthood. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  14. An iterative shrinkage approach to total-variation image restoration.

    PubMed

    Michailovich, Oleg V

    2011-05-01

    The problem of restoration of digital images from their degraded measurements plays a central role in a multitude of practically important applications. A particularly challenging instance of this problem occurs in the case when the degradation phenomenon is modeled by an ill-conditioned operator. In such a situation, the presence of noise makes it impossible to recover a valuable approximation of the image of interest without using some a priori information about its properties. Such a priori information--commonly referred to as simply priors--is essential for image restoration, rendering it stable and robust to noise. Moreover, using the priors makes the recovered images exhibit some plausible features of their original counterpart. Particularly, if the original image is known to be a piecewise smooth function, one of the standard priors used in this case is defined by the Rudin-Osher-Fatemi model, which results in total variation (TV) based image restoration. The current arsenal of algorithms for TV-based image restoration is vast. In this present paper, a different approach to the solution of the problem is proposed based upon the method of iterative shrinkage (aka iterated thresholding). In the proposed method, the TV-based image restoration is performed through a recursive application of two simple procedures, viz. linear filtering and soft thresholding. Therefore, the method can be identified as belonging to the group of first-order algorithms which are efficient in dealing with images of relatively large sizes. Another valuable feature of the proposed method consists in its working directly with the TV functional, rather then with its smoothed versions. Moreover, the method provides a single solution for both isotropic and anisotropic definitions of the TV functional, thereby establishing a useful connection between the two formulae. Finally, a number of standard examples of image deblurring are demonstrated, in which the proposed method can provide restoration results of superior quality as compared to the case of sparse-wavelet deconvolution.

  15. Magnitude of long-term non-lithostatic pressure variations in lithospheric processes: insight from thermo-mechanical subduction/collision models

    NASA Astrophysics Data System (ADS)

    Gerya, Taras

    2014-05-01

    On the one hand, the principle of lithostatic pressure is habitually used in metamorphic geology to calculate paleo-depths of metamorphism from mineralogical pressure estimates given by geobarometry. On the other hand, it is obvious that this lithostatic (hydrostatic) pressure principle should only be valid for an ideal case of negligible deviatoric stresses during the long-term development of the entire tectono-metamorphic system - the situation, which newer comes to existence in natural lithospheric processes. The question is therefore not "Do non-lithostatic pressure variations exist?" but " What is the magnitude of long-term non-lithostatic pressure variations in various lithospheric processes, which can be recorded by mineral equilibria of respective metamorphic rocks?". The later question is, in particular, relevant for various types of high-pressure (HP) and ultrahigh-pressure (UHP) rocks, which are often produced in convergent plate boundary settings (e.g., Hacker and Gerya, 2013). This question, can, in particular, be answered with the use of thermo-mechanical models of subduction/collision processes employing realistic P-T-stress-dependent visco-elasto-brittle/plastic rheology of rocks. These models suggest that magnitudes of pressure deviations from lithostatic values can range >50% underpressure to >100% overpressure, mainly in the regions of bending of rheologically strong mantle lithosphere (Burg and Gerya, 2005; Li et al., 2010). In particular, strong undepresures along normal faults forming within outer rise regions of subducting plates can be responsible for downward water suction and deep hydration of oceanic slabs (Faccenda et al., 2009). Weaker HP and UHP rocks of subduction/collision channels are typically subjected to lesser non-lithostatic pressure variations with characteristic magnitudes ranging within 10-20% from the lithostatic values (Burg and Gerya, 2005; Li et al., 2010). The strength of subducted crustal rocks and the degree of confinement of the subduction/collision channel are the key factors controlling this magnitude (Burg and Gerya, 2005; Li et al., 2010). High-temperature (>700 C) UHP rocks formed by continental crust subduction typically demonstrate negligible non-lithostatic pressure variations at peak metamorphic conditions, although these variations can be larger at the prograde stage (Gerya et al., 2008; Li et al., 2010). However, the variability of tectonic mechanisms by which UHP rocks can form (e.g., Sizova et al., 2012; Hacker and Gerya, 2013) precludes generalization of this result for all types of UHP-complexes. References Burg, J.-P., Gerya, T.V. (2005) Viscous heating and thermal doming in orogenic metamorphism: numerical modeling and geological implications. J. Metamorph. Geol., 23, 75-95. Faccenda, M., Gerya, T.V., Burlini, L. (2009) Deep slab hydration induced by bending related variations in tectonic pressure. Nature Geoscience, 2, 790-793. Gerya T.V., Perchuk, L.L., Burg J.-P. (2008) Transient hot channels: perpetrating and regurgitating ultrahigh-pressure, high temperature crust-mantle associations in collision belts. Lithos, 103, 236-256. Hacker, B., Gerya, T.V. (2013) Paradigms, new and old, for ultrahigh-pressure tectonism. Tectonophysics, 603, 79-88. Li, Z., Gerya, T.V., Burg, J.P. (2010) Influence of tectonic overpressure on P-T paths of HP-UHP rocks in continental collision zones: Thermomechanical modelling. J. Metamorphic Geol., 28, 227-247. Sizova, E., Gerya, T., Brown M. (2012) Exhumation mechanisms of melt-bearing ultrahigh pressure crustal rocks during collision of spontaneously moving plates. Journal of Metamorphic Geology, 30, 927-955.

  16. Cultural variations in children's coping behaviour, TV viewing time, and family functioning.

    PubMed

    Chen, J-L; Kennedy, C

    2005-09-01

    To examine children's coping behaviour, TV viewing hours and family functioning in four ethnic groups and factors related to children's coping behaviour. This study was part of two larger research projects investigating children's health behaviours in the United States and Taiwan. Fifty-six White American children of European ancestry, 66 Mexican American children, 68 Chinese American children and 95 native Taiwanese children were included in the analysis. Standardized instruments were used to measure coping strategies, children's TV viewing hours and family functioning. There were significant differences in the types of stressor that children of different ethnicity reported. Similarities and differences were found in the four ethnic groups regarding the top five most frequently used and most effective coping strategies. Multiple regressions identified two variables that contributed significantly to the variance in the frequency of children's coping strategies--ethnicity and poorer behaviour control in the family. Ethnicity was the only variable found to contribute to the variance in coping effectiveness. Significant differences were found in the number of hours children spent watching TV. Findings suggest that children of different ethnicity utilized different types of coping strategies and ethnicity is one of the important factors related to children's coping behaviour. These findings provide evidence for nurses to assess children's coping behaviour and TV viewing and provide children with healthier alternatives.

  17. Switched Broadband Services For The Home

    NASA Astrophysics Data System (ADS)

    Sawyer, Don M.

    1990-01-01

    In considering the deployment of fiber optics to the residence, two critical questions arise: what are the leading services that could be offered to justify the required investment; and what is the nature of the business that would offer these services to the consumer ? This talk will address these two questions together with the related issue of how the "financial engine" of today's television distribution infrastructure - TV advertising - would be affected by an open access system based on fiber optics coupled with broadband switching. On the business side, the talk concludes that the potential for open ended capacity expansion, fair competition between service providers, and new interactive services inherent in an open access, switched broadband system are the critical items in differentiating it from existing video and TV distribution systems. On the question of broadband services, the talk will highlight several new opportunities together with some findings from recent market research conducted by BNR. The talk will show that there are variations on existing services plus many new services that could be offered and which have real consumer appeal. The postulated open access system discussed here is visualized as having ultimately 1,000 to 2,000 video channels available to the consumer. Although this may appear to hopelessly fragment the TV audience and destroy the current TV advertising infrastructure, the technology of open access, switched broadband will present many new advertising techniques, which have the potential to be far more effective than those available today. Some of these techniques will be described in this talk.

  18. Playing active video games increases energy expenditure in children.

    PubMed

    Graf, Diana L; Pratt, Lauren V; Hester, Casey N; Short, Kevin R

    2009-08-01

    To compare energy expenditure rates in children playing the physically active video games, Dance Dance Revolution (DDR) and Nintendo's Wii Sports in relation to treadmill walking. Energy expenditure, heart rate, step rate, and perceived exertion were measured in 14 boys and 9 girls (ages 10-13 years; BMI at 3-98th percentile for age and gender) while watching television at rest, playing DDR at 2 skill levels, playing Wii bowling and boxing, and walking at 2.6, 4.2, and 5.7 km/h. Arterial elasticity was measured at rest and immediately after gaming. Compared with watching television, energy expenditure while gaming or walking increased 2- to 3-fold. Similarly, high rates of energy expenditure, heart rate, and perceived exertion were elicited from playing Wii boxing, DDR level 2, or walking at 5.7 km/h. This occurred despite variations in step rate among activities, reflecting greater use of upper body during Wii play (lowest step rate) than during walking (highest step rate) or DDR play. Wii bowling and beginner level DDR elicited a 2-fold increase in energy expenditure compared to television watching. Large-artery elasticity declined immediately after both DDR and Wii. The change was inversely related to the increment in energy expenditure above rest achieved during the activity. Energy expenditure during active video game play is comparable to moderate-intensity walking. Thus, for children who spend considerable time playing electronic screen games for entertainment, physically active games seem to be a safe, fun, and valuable means of promoting energy expenditure.

  19. Depictions of substance use in reality television: a content analysis of The Osbournes

    PubMed Central

    Blair, Nicole A; Yue, So Kuen; Singh, Ranbir; Bernhardt, Jay M

    2005-01-01

    Objective To determine the source and slant of messages in a reality television programme that may promote or inhibit health related or risky behaviours. Design Coding visual and verbal references to alcohol, tobacco, and other drug (ATOD) use in The Osbournes. Review methods Three reviewers watched all 10 episodes of the first season and coded incidents of substance use according to the substance used (alcohol, tobacco, or drugs), the way use was portrayed (visually or verbally), the source of the message (the character in the show involved in the incident), and the slant of the incident (endorsement or rejection). Main outcome measures The variation in number of messages in an average episode, the slant of messages, and message source. Results The average number of messages per episode was 9.1 (range 2-17). Most drug use messages (15, 54%) implied rejection of drugs, but most alcohol messages (30, 64%) and tobacco messages (12, 75%) implied endorsements for using these substances. Most rejections (34, 94%) were conveyed verbally, but most endorsements (36, 65%) were conveyed visually. Messages varied in frequency and slant by source. Conclusions The reality television show analysed in this study contains numerous messages on substance use that imply both rejection and endorsement of use. The juxtaposition of verbal rejection messages and visual endorsement messages, and the depiction of contradictory messages about substance use from show characters, may send mixed messages to viewers about substance use. PMID:16373737

  20. A sequential solution for anisotropic total variation image denoising with interval constraints

    NASA Astrophysics Data System (ADS)

    Xu, Jingyan; Noo, Frédéric

    2017-09-01

    We show that two problems involving the anisotropic total variation (TV) and interval constraints on the unknown variables admit, under some conditions, a simple sequential solution. Problem 1 is a constrained TV penalized image denoising problem; problem 2 is a constrained fused lasso signal approximator. The sequential solution entails finding first the solution to the unconstrained problem, and then applying a thresholding to satisfy the constraints. If the interval constraints are uniform, this sequential solution solves problem 1. If the interval constraints furthermore contain zero, the sequential solution solves problem 2. Here uniform interval constraints refer to all unknowns being constrained to the same interval. A typical example of application is image denoising in x-ray CT, where the image intensities are non-negative as they physically represent linear attenuation coefficient in the patient body. Our results are simple yet seem unknown; we establish them using the Karush-Kuhn-Tucker conditions for constrained convex optimization.

  1. Total Variation Denoising and Support Localization of the Gradient

    NASA Astrophysics Data System (ADS)

    Chambolle, A.; Duval, V.; Peyré, G.; Poon, C.

    2016-10-01

    This paper describes the geometrical properties of the solutions to the total variation denoising method. A folklore statement is that this method is able to restore sharp edges, but at the same time, might introduce some staircasing (i.e. “fake” edges) in flat areas. Quite surprisingly, put aside numerical evidences, almost no theoretical result are available to backup these claims. The first contribution of this paper is a precise mathematical definition of the “extended support” (associated to the noise-free image) of TV denoising. This is intuitively the region which is unstable and will suffer from the staircasing effect. Our main result shows that the TV denoising method indeed restores a piece-wise constant image outside a small tube surrounding the extended support. Furthermore, the radius of this tube shrinks toward zero as the noise level vanishes and in some cases, an upper bound on the convergence rate is given.

  2. A Televised, Web-Based Randomised Trial of an Herbal Remedy (Valerian) for Insomnia

    PubMed Central

    Oxman, Andrew D.; Flottorp, Signe; Håvelsrud, Kari; Fretheim, Atle; Odgaard-Jensen, Jan; Austvoll-Dahlgren, Astrid; Carling, Cheryl; Pallesen, Ståle; Bjorvatn, Bjørn

    2007-01-01

    Background This trial was conducted as part of a project that aims to enhance public understanding and use of research in decisions about healthcare by enabling viewers to participate in research and to follow the process, through television reports and on the web. Valerian is an herbal over-the-counter drug that is widely used for insomnia. Systematic reviews have found inconsistent and inconclusive results about its effects. Methods Participants were recruited through a weekly nationally televised health program in Norway. Enrolment and data collection were over the Internet. 405 participants who were 18 to 75 years old and had insomnia completed a two week diary-keeping run-in period without treatment and were randomised and mailed valerian or placebo tablets for two weeks. All participants and investigators were blind to treatment until after the analysis was completed. Findings For the primary outcome of a minimally important improvement in self-reported sleep quality (≥0.5 units on a 7 point scale), the difference between the valerian group (29%) and the placebo group (21%) was not statistically significant (difference 7.5%; 95% CI-0.9 to 15.9; p = 0.08). On the global self-assessment question at the end of the treatment period 5.5% (95% CI 0.2 to 10.8) more participants in the valerian group perceived their sleep as better or much better (p = 0.04). There were similar trends favouring the valerian group for night awakenings (difference = 6.0%, 95% CI-0.5 to 12.5) and sleep duration (difference = 7.5%, 95% CI-1.0 to 16.1). There were no serious adverse events and no important or statistically significant differences in minor adverse events. Interpretation Based on this and previous studies, valerian appears to be safe, but with modest beneficial effects at most on insomnia compared to placebo. The combined use of television and the Internet in randomised trials offers opportunities to answer questions about the effects of health care interventions and to improve public understanding and use of randomised trials. Trial Registration Controlled-Trials.com ISRCTN72748991 PMID:17940604

  3. Independent transmission of sign language interpreter in DVB: assessment of image compression

    NASA Astrophysics Data System (ADS)

    Zatloukal, Petr; Bernas, Martin; Dvořák, LukáÅ.¡

    2015-02-01

    Sign language on television provides information to deaf that they cannot get from the audio content. If we consider the transmission of the sign language interpreter over an independent data stream, the aim is to ensure sufficient intelligibility and subjective image quality of the interpreter with minimum bit rate. The work deals with the ROI-based video compression of Czech sign language interpreter implemented to the x264 open source library. The results of this approach are verified in subjective tests with the deaf. They examine the intelligibility of sign language expressions containing minimal pairs for different levels of compression and various resolution of image with interpreter and evaluate the subjective quality of the final image for a good viewing experience.

  4. Wanting to Maximize the Positive and Minimize the Negative: Implications for Mixed Affective Experience in American and Chinese Contexts

    PubMed Central

    Sims, Tamara; Tsai, Jeanne L.; Jiang, Da; Wang, Yaheng; Fung, Helene H.; Zhang, Xiulan

    2016-01-01

    Previous studies have demonstrated that European Americans have fewer mixed affective experiences (i.e., are less likely to experience the bad with the good) compared to Chinese. In this paper, we argue that these cultural differences are due to “ideal affect,” or how people ideally want to feel. Specifically, we predict that people from individualistic cultures want to maximize positive and minimize negative affect more than people from collectivistic cultures, and as a result, they are less likely to actually experience mixed emotions (reflected by a more negative within-person correlation between actual positive and negative affect). We find support for this prediction in two experience sampling studies conducted in the U.S. and China (Studies 1 and 2). In addition, we demonstrate that ideal affect is a distinct construct from dialectical view of the self, which has also been related to mixed affective experience (Study 3). Finally, in Study 4, we demonstrate that experimentally manipulating the desire to maximize the positive and minimize the negative alters participants' actual experience of mixed emotions during a pleasant (but not unpleasant or combined pleasant and unpleasant) television clip in the U.S. and Hong Kong. Together, these findings suggest that across cultures, how people want to feel shapes how they actually feel, particularly people's mixed affective experience. PMID:26121525

  5. Surface features on Mars: Ground-based albedo and radar compared with Mariner 9 topography

    NASA Technical Reports Server (NTRS)

    Frey, H.

    1973-01-01

    Earth-based albedo maps of Mars were compared with Mariner 9 television data and ground-based radar profiles to investigate the nature of the bright and dark albedo features. Little correlation was found except at the boundaries of classical albedo features, where some topographic control is indicated. Wind-blown dust models for seasonal and secular albedo variations are supported, but it is not clear whether the fines are derived from bright or dark parent rock. Mars, like the Earth and Moon, has probably generated two distinct types of crustal material.

  6. Precision Measurement of the Proton Flux in Primary Cosmic Rays from Rigidity 1 GV to 1.8 TV with the Alpha Magnetic Spectrometer on the International Space Station.

    PubMed

    Aguilar, M; Aisa, D; Alpat, B; Alvino, A; Ambrosi, G; Andeen, K; Arruda, L; Attig, N; Azzarello, P; Bachlechner, A; Barao, F; Barrau, A; Barrin, L; Bartoloni, A; Basara, L; Battarbee, M; Battiston, R; Bazo, J; Becker, U; Behlmann, M; Beischer, B; Berdugo, J; Bertucci, B; Bigongiari, G; Bindi, V; Bizzaglia, S; Bizzarri, M; Boella, G; de Boer, W; Bollweg, K; Bonnivard, V; Borgia, B; Borsini, S; Boschini, M J; Bourquin, M; Burger, J; Cadoux, F; Cai, X D; Capell, M; Caroff, S; Casaus, J; Cascioli, V; Castellini, G; Cernuda, I; Cerreta, D; Cervelli, F; Chae, M J; Chang, Y H; Chen, A I; Chen, H; Cheng, G M; Chen, H S; Cheng, L; Chou, H Y; Choumilov, E; Choutko, V; Chung, C H; Clark, C; Clavero, R; Coignet, G; Consolandi, C; Contin, A; Corti, C; Cortina Gil, E; Coste, B; Creus, W; Crispoltoni, M; Cui, Z; Dai, Y M; Delgado, C; Della Torre, S; Demirköz, M B; Derome, L; Di Falco, S; Di Masso, L; Dimiccoli, F; Díaz, C; von Doetinchem, P; Donnini, F; Du, W J; Duranti, M; D'Urso, D; Eline, A; Eppling, F J; Eronen, T; Fan, Y Y; Farnesini, L; Feng, J; Fiandrini, E; Fiasson, A; Finch, E; Fisher, P; Galaktionov, Y; Gallucci, G; García, B; García-López, R; Gargiulo, C; Gast, H; Gebauer, I; Gervasi, M; Ghelfi, A; Gillard, W; Giovacchini, F; Goglov, P; Gong, J; Goy, C; Grabski, V; Grandi, D; Graziani, M; Guandalini, C; Guerri, I; Guo, K H; Haas, D; Habiby, M; Haino, S; Han, K C; He, Z H; Heil, M; Hoffman, J; Hsieh, T H; Huang, Z C; Huh, C; Incagli, M; Ionica, M; Jang, W Y; Jinchi, H; Kanishev, K; Kim, G N; Kim, K S; Kirn, Th; Kossakowski, R; Kounina, O; Kounine, A; Koutsenko, V; Krafczyk, M S; La Vacca, G; Laudi, E; Laurenti, G; Lazzizzera, I; Lebedev, A; Lee, H T; Lee, S C; Leluc, C; Levi, G; Li, H L; Li, J Q; Li, Q; Li, Q; Li, T X; Li, W; Li, Y; Li, Z H; Li, Z Y; Lim, S; Lin, C H; Lipari, P; Lippert, T; Liu, D; Liu, H; Lolli, M; Lomtadze, T; Lu, M J; Lu, S Q; Lu, Y S; Luebelsmeyer, K; Luo, J Z; Lv, S S; Majka, R; Mañá, C; Marín, J; Martin, T; Martínez, G; Masi, N; Maurin, D; Menchaca-Rocha, A; Meng, Q; Mo, D C; Morescalchi, L; Mott, P; Müller, M; Ni, J Q; Nikonov, N; Nozzoli, F; Nunes, P; Obermeier, A; Oliva, A; Orcinha, M; Palmonari, F; Palomares, C; Paniccia, M; Papi, A; Pauluzzi, M; Pedreschi, E; Pensotti, S; Pereira, R; Picot-Clemente, N; Pilo, F; Piluso, A; Pizzolotto, C; Plyaskin, V; Pohl, M; Poireau, V; Postaci, E; Putze, A; Quadrani, L; Qi, X M; Qin, X; Qu, Z Y; Räihä, T; Rancoita, P G; Rapin, D; Ricol, J S; Rodríguez, I; Rosier-Lees, S; Rozhkov, A; Rozza, D; Sagdeev, R; Sandweiss, J; Saouter, P; Sbarra, C; Schael, S; Schmidt, S M; Schulz von Dratzig, A; Schwering, G; Scolieri, G; Seo, E S; Shan, B S; Shan, Y H; Shi, J Y; Shi, X Y; Shi, Y M; Siedenburg, T; Son, D; Spada, F; Spinella, F; Sun, W; Sun, W H; Tacconi, M; Tang, C P; Tang, X W; Tang, Z C; Tao, L; Tescaro, D; Ting, Samuel C C; Ting, S M; Tomassetti, N; Torsti, J; Türkoğlu, C; Urban, T; Vagelli, V; Valente, E; Vannini, C; Valtonen, E; Vaurynovich, S; Vecchi, M; Velasco, M; Vialle, J P; Vitale, V; Vitillo, S; Wang, L Q; Wang, N H; Wang, Q L; Wang, R S; Wang, X; Wang, Z X; Weng, Z L; Whitman, K; Wienkenhöver, J; Wu, H; Wu, X; Xia, X; Xie, M; Xie, S; Xiong, R Q; Xin, G M; Xu, N S; Xu, W; Yan, Q; Yang, J; Yang, M; Ye, Q H; Yi, H; Yu, Y J; Yu, Z Q; Zeissler, S; Zhang, J H; Zhang, M T; Zhang, X B; Zhang, Z; Zheng, Z M; Zhuang, H L; Zhukov, V; Zichichi, A; Zimmermann, N; Zuccon, P; Zurbach, C

    2015-05-01

    A precise measurement of the proton flux in primary cosmic rays with rigidity (momentum/charge) from 1 GV to 1.8 TV is presented based on 300 million events. Knowledge of the rigidity dependence of the proton flux is important in understanding the origin, acceleration, and propagation of cosmic rays. We present the detailed variation with rigidity of the flux spectral index for the first time. The spectral index progressively hardens at high rigidities.

  7. Apollo experience report: Command and service module communications subsystem

    NASA Technical Reports Server (NTRS)

    Lattier, E. E., Jr.

    1974-01-01

    The development of spacecraft communications hardware from design to operation is described. Programs, requirements, specifications, and design approaches for a variety of functions (such as voice, telemetry, television, and antennas) are reviewed. Equipment environmental problems such as vibration, extreme temperature variation, and zero gravity are discussed. A review of the development of managerial techniques used in refining the roles of prime and subcontractors is included. The hardware test program is described in detail as it progressed from breadboard design to manned flight system evaluations. Finally, a series of actions is recommended to managers of similar projects to facilitate administration.

  8. Inhibition coefficient and molecular diversity of multi stress tolerant Trichoderma as potential biocontrol agent against Sclerotium rolfsii Sacc.

    PubMed

    Hirpara, Darshna G; Gajera, H P; Hirapara, Jaydeep G; Golakiya, B A

    2017-11-01

    Trichoderma is one of the most exploited biocontrol agent for the management of plant diseases. Twenty strains of Trichoderma (six of T. harzianum, four of T. viride, three of T. virens, three of T. koningii, each one of T. hamatum, T. reesei, T. parceramosum and Trichoderma spp.) subjected to in vitro antagonism up to 12days after inoculation against Sclerotium rolfsii Sacc. causing stem rot in groundnut. A new concept was developed to determine inhibition coefficient representing pathogen biology and biocontrol related biophysical variables. Results explained differential inhibition coefficient of test pathogen by Trichoderma antagonists. The inhibition coefficient of test pathogen was examined highest (91.13%) by T. virens NBAII Tvs12 followed by T. virens MTCC 794 (89.33%) and T. koningii MTCC 796 (62.39%). Microscopic study confirmed biocontrol mechanism as mycoparasitism for Tvs12 and antibiosis for T. koningii MTCC 796. The sclerotial biogenesis of test pathogen was elevated during weak antagonism and diminished in interactions with strong antagonists. The inhibition coefficient of S. rolfsii was significantly negatively correlated with sclerotia formation and lipid peroxidation during the antagonism. Trichoderma strains were screened for fungicides (carbendazim and tebuconazole, thiram and mancozeb) and abiotic stress (drought and salt) tolerance. Results indicated that T. koningii MTCC 796 efficiently grew better than the other strains with maximum radial growth under adverse conditions. The genetic variability among the Trichoderma was determined using 34 gene specific markers which amplified 146 alleles. The SSR similarities explained substantial diversity (15 to 87%) across Trichoderma strains and pathogen S. rolfsii. Principal coordinates analysis (PCA) were comparable to the cluster analysis and first three most informative PC components explained 64.45% of the total variation. In PCA, potent antagonists appear to be distinct from other strains. Five SSR markers T1F/T1R (311) , TvCTT56f/TvCTT56r (387) , TvGAT18f/TvGAT18r (364) , TvCA39f/TvCA39r (196) and TvAG29f/TvAG29r (418) found to be unique to distinguish best antagonist strain Tvs12. However, MTCC 796 was examined most stress tolerant strain with better inhibition coefficient which might be useful to control the disease under adverse conditions or as a part of integrated pest management. Copyright © 2017. Published by Elsevier B.V.

  9. Content Themes of Alcohol Advertising in US Television — Latent Class Analysis

    PubMed Central

    Morgenstern, Matthis; Schoeppe, Franziska; Campbell, Julie; Braam, Marloes W.G.; Stoolmiller, Michael; Sargent, James D.

    2015-01-01

    Background There is little alcohol research that reports on the thematic contents of contemporary alcohol advertisements in US television. Studies of alcohol ads from two decades ago did not identify “partying” as a social theme. Aim of the present study was to describe and classify alcohol advertisements aired in national television in terms of contents, airing times, and channel placements and to identify different marketing strategies of alcohol brands. Methods Content analysis of all ads from the top 20 US beer and spirit brands aired between July 2009 and June 2011. These were 581 unique alcohol ads accounting for 272,828 (78%) national television airings. Ads were coded according to predefined definitions of 13 content areas. A latent class analysis (LCA) was conducted to define content cluster themes and determine alcoholic brands that were more likely to exploit these themes. Results About half of the advertisements (46%) were aired between 3am and 8pm, and the majority were placed either in Entertainment (40%) and Sports (38%) channels. Beer ads comprised 64% of the sample, with significant variation in airing times and channels between types of products and brands. LCA revealed five content classes that exploited the “Partying”, “Quality”, “Sports”, “Manly”, and “Relax” themes. The partying class, indicative of ad messages surrounding partying, love and sex, was the dominant theme, comprising 42% of all advertisements. Ads for alcopops, flavored spirits, and liqueur were more likely to belong to the party class, but there were also some beer brands (Corona, Heineken) where more than 67% of ads exploited this theme. Conclusions This is the first analysis to identify a partying theme to contemporary alcohol advertising. Future analyses can now determine whether exposure to that or other themes predicts alcohol misuse among youth audiences. PMID:26207317

  10. Widespread covariation of early environmental exposures and trait-associated polygenic variation.

    PubMed

    Krapohl, E; Hannigan, L J; Pingault, J-B; Patel, H; Kadeva, N; Curtis, C; Breen, G; Newhouse, S J; Eley, T C; O'Reilly, P F; Plomin, R

    2017-10-31

    Although gene-environment correlation is recognized and investigated by family studies and recently by SNP-heritability studies, the possibility that genetic effects on traits capture environmental risk factors or protective factors has been neglected by polygenic prediction models. We investigated covariation between trait-associated polygenic variation identified by genome-wide association studies (GWASs) and specific environmental exposures, controlling for overall genetic relatedness using a genomic relatedness matrix restricted maximum-likelihood model. In a UK-representative sample ( n = 6,710), we find widespread covariation between offspring trait-associated polygenic variation and parental behavior and characteristics relevant to children's developmental outcomes-independently of population stratification. For instance, offspring genetic risk for schizophrenia was associated with paternal age ( R 2 = 0.002; P = 1e-04), and offspring education-associated variation was associated with variance in breastfeeding ( R 2 = 0.021; P = 7e-30), maternal smoking during pregnancy ( R 2 = 0.008; P = 5e-13), parental smacking ( R 2 = 0.01; P = 4e-15), household income ( R 2 = 0.032; P = 1e-22), watching television ( R 2 = 0.034; P = 5e-47), and maternal education ( R 2 = 0.065; P = 3e-96). Education-associated polygenic variation also captured covariation between environmental exposures and children's inattention/hyperactivity, conduct problems, and educational achievement. The finding that genetic variation identified by trait GWASs partially captures environmental risk factors or protective factors has direct implications for risk prediction models and the interpretation of GWAS findings.

  11. Accelerated echo planar J-resolved spectroscopic imaging in prostate cancer: a pilot validation of non-linear reconstruction using total variation and maximum entropy.

    PubMed

    Nagarajan, Rajakumar; Iqbal, Zohaib; Burns, Brian; Wilson, Neil E; Sarma, Manoj K; Margolis, Daniel A; Reiter, Robert E; Raman, Steven S; Thomas, M Albert

    2015-11-01

    The overlap of metabolites is a major limitation in one-dimensional (1D) spectral-based single-voxel MRS and multivoxel-based MRSI. By combining echo planar spectroscopic imaging (EPSI) with a two-dimensional (2D) J-resolved spectroscopic (JPRESS) sequence, 2D spectra can be recorded in multiple locations in a single slice of prostate using four-dimensional (4D) echo planar J-resolved spectroscopic imaging (EP-JRESI). The goal of the present work was to validate two different non-linear reconstruction methods independently using compressed sensing-based 4D EP-JRESI in prostate cancer (PCa): maximum entropy (MaxEnt) and total variation (TV). Twenty-two patients with PCa with a mean age of 63.8 years (range, 46-79 years) were investigated in this study. A 4D non-uniformly undersampled (NUS) EP-JRESI sequence was implemented on a Siemens 3-T MRI scanner. The NUS data were reconstructed using two non-linear reconstruction methods, namely MaxEnt and TV. Using both TV and MaxEnt reconstruction methods, the following observations were made in cancerous compared with non-cancerous locations: (i) higher mean (choline + creatine)/citrate metabolite ratios; (ii) increased levels of (choline + creatine)/spermine and (choline + creatine)/myo-inositol; and (iii) decreased levels of (choline + creatine)/(glutamine + glutamate). We have shown that it is possible to accelerate the 4D EP-JRESI sequence by four times and that the data can be reliably reconstructed using the TV and MaxEnt methods. The total acquisition duration was less than 13 min and we were able to detect and quantify several metabolites. Copyright © 2015 John Wiley & Sons, Ltd.

  12. The analysis of factors affecting the threshold on repeated 18F-FDG-PET/CT investigations measured by the PERCIST protocol in patients with esophageal carcinoma.

    PubMed

    Fencl, Pavel; Belohlavek, Otakar; Harustiak, Tomas; Zemanova, Milada

    2012-11-01

    When applying the PET Response Criteria in Solid Tumors protocol, a threshold value based on standardized uptake value corrected to lean body mass (SUL) in liver parenchyma, or in the blood pool, is used: to metabolically specify a measurable lesion; to calculate metabolic tumor volume (mTV) and its product total lesion glycolysis (TLG); and as a limit for response measurement. The problem with using changes in glucose metabolism as a marker for response to therapy is its reproducibility on test-retest examinations. Therefore, before the evaluation of tumor treatment response, we verified our diagnostic protocol for homogeneity using the PET Response Criteria in Solid Tumors quality parameters. In addition, we analyzed the effect of the time span between examinations on the average value of SUL (SUL MEAN) in liver parenchyma at three different points: first at baseline (BL), after the first course of chemotherapy (ChT1), and finally after finishing therapy (ChT3). We also analyzed the influence of SUL MEAN variation on mTV and TLG. Eighty-four patients with esophageal cancer were prospectively examined at BL using 2-deoxy-2-[18F]fluoro-D-glucose (18F-FDG)-PET/CT; 53 of 84 patients were examined after ChT1, 47 of 84 after ChT3, and 41 of 84 underwent all three examinations. Coefficient of variance (CV) and relative differences (RDw) were assessed for test-retest liver SUL values. The influence of liver SUL MEAN to mTV and TLG was modeled on BL examinations by artificial changes in liver SUL MEAN by ± 20%. No significant differences were found in test-retest liver SUL MEAN values. Comparing BL with ChT1, BL with ChT3, and ChT1 with ChT3, the CV of the liver SUL MEAN was 10.4, 10.7, and 10.3%; nevertheless, in 34.0, 38.3, and 36.6% of these examinations, respectively, the liver average SUL MEAN values exceeded the limit for inclusion in the study; that is, the difference was less than ± 0.3 U and ± 20%. The corresponding CV of blood background was 14.9, 16.5, and 17.2%. The artificial decrease of -20% in the liver SUL MEAN resulted in an increase of +43.6% in mTV and of +20.4% in TLG, whereas an increase of +20% in the liver SUL MEAN resulted in a decrease of -20.6% in mTV and -11.9% in TLG. SUL MEAN values in reference tissues (liver parenchyma or descending aorta) measured before chemotherapy did not differ significantly from those measured during chemotherapy. The CV of liver SUL MEAN was comparable to that seen in published data, but some patients had to be excluded from the study because of the individual variability of their mean liver SUL MEAN, which consequently hinders the clinical usage of mTV and TLG. Even in the standardized protocol, all potential sources of variability should be minimized.

  13. Protective broadband window coatings

    NASA Astrophysics Data System (ADS)

    Askinazi, Joel; Narayanan, Authi A.

    1997-06-01

    Optical windows employed in current and future airborne and ground based optical sensor systems are required to provide long service life under extreme environmental conditions including blowing sand and high speed rain. State of the art sensor systems are employing common aperture windows which must provide optical bandpasses from the TV to the LWIR. Operation Desert Storm experience indicates that current optical coatings provide limited environmental protection which adversely affects window life cycle cost. Most of these production coatings also have limited optical bandpasses (LWIR, MWIR, or TV-NIR). A family of optical coatings has been developed which provide a significant increase in rain and sand impact protection to current optical window materials. These coatings can also be tailored to provide either narrow optical bandwidth (e.g., LWIR) or broadband transmittance (TV- LWIR). They have been applied to a number of standard optical window materials. These coating have successfully completed airborne rain and sand abrasion test with minimal impact on optical window performance. Test results are presented. Low cost service life is anticipated as well as the ability to operate windows in even more taxing environments than currently feasible.

  14. Emergency department visits during an Olympic gold medal television broadcast

    PubMed Central

    Redelmeier, Donald A; Vermeulen, Marian J

    2011-01-01

    Background Practice pattern variations are often attributed to physician decision-making with no accounting for patient preferences. Objective To test whether a mass media television broadcast unrelated to health was associated with changes in the rate and characteristics of visits for acute emergency care. Design Time-series analysis of emergency department visits for any reason. Subjects Population-based sample of all patients seeking emergency care in Ontario, Canada. Measures The broadcast day was defined as the Olympic men’s gold medal ice hockey game final. The control days were defined as the 6 Sundays before and after the broadcast day. Results A total of 99 447 visits occurred over the 7 Sundays, of which 13 990 occurred on the broadcast day. Comparing the broadcast day with control days, we found no significant difference in the hourly rate of visits before the broadcast (544 vs 537, p = 0.41) or after the broadcast (647 vs 639, p = 0.55). In contrast, we observed a significant reduction in hourly rate of visits during the broadcast (647 vs 783, p < 0.001), equal to an absolute decrease of 409 patients, a relative decrease of 17% (95% confidence interval 13–21), or about 136 fewer patients per hour. The relative decrease during the broadcast was particularly large for adult men with low triage severity. The greatest reductions were for patients with abdominal, musculoskeletal or traumatic disorders. Conclusion Mass media television broadcasts can influence patient preferences and thereby lead to a decrease in emergency department visits. PMID:21915235

  15. Using national news events to stimulate local awareness of public policy issues.

    PubMed Central

    Convissor, R B; Vollinger, R E; Wilbur, P

    1990-01-01

    Community leaders in Atlanta, GA, the Detroit and Lansing, MI, areas, and San Francisco, CA, participated in a demonstration of techniques to disseminate information and increase public awareness of the recommendations from the Surgeon General's Workshop on Drunk Driving, held in December 1988. Local officials worked with the Public Health Service's Office for Substance Abuse Prevention, of the Alcohol, Drug Abuse, and Mental Health Administration, to educate and inform the public about the workshop recommendations as well as other alcohol-related concerns, and to encourage public involvement in their communities with the issue of alcohol-impaired driving and other alcohol-related concerns. With minimal assistance from Federal agencies and Washington-based health and public interest groups, the communities developed unique approaches to generating local television, radio, and newspaper coverage of an event that had originated as national news. The events demonstrated that, with minimal Federal resources and support, local groups can create media attention in conjunction with national news, and local media events can lead to successful community activism. The techniques can be applied by other community groups to gain sufficient news media attention to encourage the public to organize around issues of common concern. PMID:2113684

  16. Algorithm for protecting light-trees in survivable mesh wavelength-division-multiplexing networks

    NASA Astrophysics Data System (ADS)

    Luo, Hongbin; Li, Lemin; Yu, Hongfang

    2006-12-01

    Wavelength-division-multiplexing (WDM) technology is expected to facilitate bandwidth-intensive multicast applications such as high-definition television. A single fiber cut in a WDM mesh network, however, can disrupt the dissemination of information to several destinations on a light-tree based multicast session. Thus it is imperative to protect multicast sessions by reserving redundant resources. We propose a novel and efficient algorithm for protecting light-trees in survivable WDM mesh networks. The algorithm is called segment-based protection with sister node first (SSNF), whose basic idea is to protect a light-tree using a set of backup segments with a higher priority to protect the segments from a branch point to its children (sister nodes). The SSNF algorithm differs from the segment protection scheme proposed in the literature in how the segments are identified and protected. Our objective is to minimize the network resources used for protecting each primary light-tree such that the blocking probability can be minimized. To verify the effectiveness of the SSNF algorithm, we conduct extensive simulation experiments. The simulation results demonstrate that the SSNF algorithm outperforms existing algorithms for the same problem.

  17. Find Cancer Early: Evaluation of a Community Education Campaign to Increase Awareness of Cancer Signs and Symptoms in People in Regional Western Australians.

    PubMed

    Croager, Emma Jane; Gray, Victoria; Pratt, Iain Stephen; Slevin, Terry; Pettigrew, Simone; Holman, C D'arcy; Bulsara, Max; Emery, Jon

    2018-01-01

    Cancer outcomes for people living in rural and remote areas are worse than for those living in urban areas. Although access to and quality of cancer treatment are important determinants of outcomes, delayed presentation has been observed in rural patients. Formative research with people from rural Western Australia (WA) led to the Find Cancer Early campaign. Find Cancer Early was delivered in three regions of WA, with two other regions acting as controls. Staff delivered the campaign using a community engagement approach, including promotion in local media. Television communications were not used to minimize contamination in the control regions. The campaign evaluation was undertaken at 20 months via a computer-assisted telephone interview (CATI) survey comparing campaign and control regions. The primary outcome variable was knowledge of cancer signs and symptoms. Recognition and recall of Find Cancer Early and symptom knowledge were higher in the campaign regions. More than a quarter of those who were aware of the campaign reported seeing the GP as a result of their exposure. Despite limited use of mass media, Find Cancer Early successfully improved knowledge of cancer symptoms and possibly led to changes in behavior. Social marketing campaigns using community development can raise awareness and knowledge of a health issue in the absence of television advertising.

  18. LH2 tank pressure control by thermodynamic vent system (TVS) at zero gravity

    NASA Astrophysics Data System (ADS)

    Wang, B.; Huang, Y. H.; Chen, Z. C.; Wu, J. Y.; Li, P.; Sun, P. J.

    2017-02-01

    Thermodynamic vent system (TVS) is employed for pressure control of propellant tanks at zero gravity. An analytical lumped parameter model is developed to predict pressure variation in an 18.09 m3 liquid hydrogen tank equipped with TVS. Mathematical simulations are carried out assuming tank is filled up to 75% volume (liquid mass equals to 945 kg) and is subjected to heat flux of 0.76 W/m2. Tank pressure controls at 165.5-172.4, 165.5-179.3 and 165.5-182.2 kPa are compared with reference to number of vent cycles, vent duration per cycle and loss of hydrogen. Analysis results indicate that the number of vent cycles significantly decreases from 62 to 21 when tank pressure control increases from 6.9 to 20.4 kPa. Also, duration of vent cycle increases from 63 to 152 and cycle duration decreases from 3920 to 3200 s. Further, the analysis result suggests that LH2 evaporation loss per day decreases from 0.17 to 0.14%. Based on the results of analysis, TVS is found effective in controlling the propellant tank pressure in zero gravity.

  19. This Ad is for You: Targeting and the Effect of Alcohol Advertising on Youth Drinking.

    PubMed

    Molloy, Eamon

    2016-02-01

    Endogenous targeting of alcohol advertisements presents a challenge for empirically identifying a causal effect of advertising on drinking. Drinkers prefer a particular media; firms recognize this and target alcohol advertising at these media. This paper overcomes this challenge by utilizing novel data with detailed individual measures of media viewing and alcohol consumption and three separate empirical techniques, which represent significant improvements over previous methods. First, controls for the average audience characteristics of the media an individual views account for attributes of magazines and television programs alcohol firms may consider when deciding where to target advertising. A second specification directly controls for each television program and magazine a person views. The third method exploits variation in advertising exposure due to a 2003 change in an industry-wide rule that governs where firms may advertise. Although the unconditional correlation between advertising and drinking by youth (ages 18-24) is strong, models that include simple controls for targeting imply, at most, a modest advertising effect. Although the coefficients are estimated less precisely, estimates with models including more rigorous controls for targeting indicate no significant effect of advertising on youth drinking. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Low-dose X-ray computed tomography image reconstruction with a combined low-mAs and sparse-view protocol.

    PubMed

    Gao, Yang; Bian, Zhaoying; Huang, Jing; Zhang, Yunwan; Niu, Shanzhou; Feng, Qianjin; Chen, Wufan; Liang, Zhengrong; Ma, Jianhua

    2014-06-16

    To realize low-dose imaging in X-ray computed tomography (CT) examination, lowering milliampere-seconds (low-mAs) or reducing the required number of projection views (sparse-view) per rotation around the body has been widely studied as an easy and effective approach. In this study, we are focusing on low-dose CT image reconstruction from the sinograms acquired with a combined low-mAs and sparse-view protocol and propose a two-step image reconstruction strategy. Specifically, to suppress significant statistical noise in the noisy and insufficient sinograms, an adaptive sinogram restoration (ASR) method is first proposed with consideration of the statistical property of sinogram data, and then to further acquire a high-quality image, a total variation based projection onto convex sets (TV-POCS) method is adopted with a slight modification. For simplicity, the present reconstruction strategy was termed as "ASR-TV-POCS." To evaluate the present ASR-TV-POCS method, both qualitative and quantitative studies were performed on a physical phantom. Experimental results have demonstrated that the present ASR-TV-POCS method can achieve promising gains over other existing methods in terms of the noise reduction, contrast-to-noise ratio, and edge detail preservation.

  1. [Computer optical topography: a study of the repeatability of the results of human body model examination].

    PubMed

    Sarnadskiĭ, V N

    2007-01-01

    The problem of repeatability of the results of examination of a plastic human body model is considered. The model was examined in 7 positions using an optical topograph for kyphosis diagnosis. The examination was performed under television camera monitoring. It was shown that variation of the model position in the camera view affected the repeatability of the results of topographic examination, especially if the model-to-camera distance was changed. A study of the repeatability of the results of optical topographic examination can help to increase the reliability of the topographic method, which is widely used for medical screening of children and adolescents.

  2. Using compressive sensing to recover images from PET scanners with partial detector rings.

    PubMed

    Valiollahzadeh, SeyyedMajid; Clark, John W; Mawlawi, Osama

    2015-01-01

    Most positron emission tomography/computed tomography (PET/CT) scanners consist of tightly packed discrete detector rings to improve scanner efficiency. The authors' aim was to use compressive sensing (CS) techniques in PET imaging to investigate the possibility of decreasing the number of detector elements per ring (introducing gaps) while maintaining image quality. A CS model based on a combination of gradient magnitude and wavelet domains (wavelet-TV) was developed to recover missing observations in PET data acquisition. The model was designed to minimize the total variation (TV) and L1-norm of wavelet coefficients while constrained by the partially observed data. The CS model also incorporated a Poisson noise term that modeled the observed noise while suppressing its contribution by penalizing the Poisson log likelihood function. Three experiments were performed to evaluate the proposed CS recovery algorithm: a simulation study, a phantom study, and six patient studies. The simulation dataset comprised six disks of various sizes in a uniform background with an activity concentration of 5:1. The simulated image was multiplied by the system matrix to obtain the corresponding sinogram and then Poisson noise was added. The resultant sinogram was masked to create the effect of partial detector removal and then the proposed CS algorithm was applied to recover the missing PET data. In addition, different levels of noise were simulated to assess the performance of the proposed algorithm. For the phantom study, an IEC phantom with six internal spheres each filled with F-18 at an activity-to-background ratio of 10:1 was used. The phantom was imaged twice on a RX PET/CT scanner: once with all detectors operational (baseline) and once with four detector blocks (11%) turned off at each of 0 ˚, 90 ˚, 180 ˚, and 270° (partially sampled). The partially acquired sinograms were then recovered using the proposed algorithm. For the third test, PET images from six patient studies were investigated using the same strategy of the phantom study. The recovered images using WTV and TV as well as the partially sampled images from all three experiments were then compared with the fully sampled images (the baseline). Comparisons were done by calculating the mean error (%bias), root mean square error (RMSE), contrast recovery (CR), and SNR of activity concentration in regions of interest drawn in the background as well as the disks, spheres, and lesions. For the simulation study, the mean error, RMSE, and CR for the WTV (TV) recovered images were 0.26% (0.48%), 2.6% (2.9%), 97% (96%), respectively, when compared to baseline. For the partially sampled images, these results were 22.5%, 45.9%, and 64%, respectively. For the simulation study, the average SNR for the baseline was 41.7 while for WTV (TV), recovered image was 44.2 (44.0). The phantom study showed similar trends with 5.4% (18.2%), 15.6% (18.8%), and 78% (60%), respectively, for the WTV (TV) images and 33%, 34.3%, and 69% for the partially sampled images. For the phantom study, the average SNR for the baseline was 14.7 while for WTV (TV) recovered image was 13.7 (11.9). Finally, the average of these values for the six patient studies for the WTV-recovered, TV, and partially sampled images was 1%, 7.2%, 92% and 1.3%, 15.1%, 87%, and 27%, 25.8%, 45%, respectively. CS with WTV is capable of recovering PET images with good quantitative accuracy from partially sampled data. Such an approach can be used to potentially reduce the cost of scanners while maintaining good image quality.

  3. Using compressive sensing to recover images from PET scanners with partial detector rings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valiollahzadeh, SeyyedMajid, E-mail: sv4@rice.edu; Clark, John W.; Mawlawi, Osama

    2015-01-15

    Purpose: Most positron emission tomography/computed tomography (PET/CT) scanners consist of tightly packed discrete detector rings to improve scanner efficiency. The authors’ aim was to use compressive sensing (CS) techniques in PET imaging to investigate the possibility of decreasing the number of detector elements per ring (introducing gaps) while maintaining image quality. Methods: A CS model based on a combination of gradient magnitude and wavelet domains (wavelet-TV) was developed to recover missing observations in PET data acquisition. The model was designed to minimize the total variation (TV) and L1-norm of wavelet coefficients while constrained by the partially observed data. The CSmore » model also incorporated a Poisson noise term that modeled the observed noise while suppressing its contribution by penalizing the Poisson log likelihood function. Three experiments were performed to evaluate the proposed CS recovery algorithm: a simulation study, a phantom study, and six patient studies. The simulation dataset comprised six disks of various sizes in a uniform background with an activity concentration of 5:1. The simulated image was multiplied by the system matrix to obtain the corresponding sinogram and then Poisson noise was added. The resultant sinogram was masked to create the effect of partial detector removal and then the proposed CS algorithm was applied to recover the missing PET data. In addition, different levels of noise were simulated to assess the performance of the proposed algorithm. For the phantom study, an IEC phantom with six internal spheres each filled with F-18 at an activity-to-background ratio of 10:1 was used. The phantom was imaged twice on a RX PET/CT scanner: once with all detectors operational (baseline) and once with four detector blocks (11%) turned off at each of 0 °, 90 °, 180 °, and 270° (partially sampled). The partially acquired sinograms were then recovered using the proposed algorithm. For the third test, PET images from six patient studies were investigated using the same strategy of the phantom study. The recovered images using WTV and TV as well as the partially sampled images from all three experiments were then compared with the fully sampled images (the baseline). Comparisons were done by calculating the mean error (%bias), root mean square error (RMSE), contrast recovery (CR), and SNR of activity concentration in regions of interest drawn in the background as well as the disks, spheres, and lesions. Results: For the simulation study, the mean error, RMSE, and CR for the WTV (TV) recovered images were 0.26% (0.48%), 2.6% (2.9%), 97% (96%), respectively, when compared to baseline. For the partially sampled images, these results were 22.5%, 45.9%, and 64%, respectively. For the simulation study, the average SNR for the baseline was 41.7 while for WTV (TV), recovered image was 44.2 (44.0). The phantom study showed similar trends with 5.4% (18.2%), 15.6% (18.8%), and 78% (60%), respectively, for the WTV (TV) images and 33%, 34.3%, and 69% for the partially sampled images. For the phantom study, the average SNR for the baseline was 14.7 while for WTV (TV) recovered image was 13.7 (11.9). Finally, the average of these values for the six patient studies for the WTV-recovered, TV, and partially sampled images was 1%, 7.2%, 92% and 1.3%, 15.1%, 87%, and 27%, 25.8%, 45%, respectively. Conclusions: CS with WTV is capable of recovering PET images with good quantitative accuracy from partially sampled data. Such an approach can be used to potentially reduce the cost of scanners while maintaining good image quality.« less

  4. A low-complexity 2-point step size gradient projection method with selective function evaluations for smoothed total variation based CBCT reconstructions.

    PubMed

    Song, Bongyong; Park, Justin C; Song, William Y

    2014-11-07

    The Barzilai-Borwein (BB) 2-point step size gradient method is receiving attention for accelerating Total Variation (TV) based CBCT reconstructions. In order to become truly viable for clinical applications, however, its convergence property needs to be properly addressed. We propose a novel fast converging gradient projection BB method that requires 'at most one function evaluation' in each iterative step. This Selective Function Evaluation method, referred to as GPBB-SFE in this paper, exhibits the desired convergence property when it is combined with a 'smoothed TV' or any other differentiable prior. This way, the proposed GPBB-SFE algorithm offers fast and guaranteed convergence to the desired 3DCBCT image with minimal computational complexity. We first applied this algorithm to a Shepp-Logan numerical phantom. We then applied to a CatPhan 600 physical phantom (The Phantom Laboratory, Salem, NY) and a clinically-treated head-and-neck patient, both acquired from the TrueBeam™ system (Varian Medical Systems, Palo Alto, CA). Furthermore, we accelerated the reconstruction by implementing the algorithm on NVIDIA GTX 480 GPU card. We first compared GPBB-SFE with three recently proposed BB-based CBCT reconstruction methods available in the literature using Shepp-Logan numerical phantom with 40 projections. It is found that GPBB-SFE shows either faster convergence speed/time or superior convergence property compared to existing BB-based algorithms. With the CatPhan 600 physical phantom, the GPBB-SFE algorithm requires only 3 function evaluations in 30 iterations and reconstructs the standard, 364-projection FDK reconstruction quality image using only 60 projections. We then applied the algorithm to a clinically-treated head-and-neck patient. It was observed that the GPBB-SFE algorithm requires only 18 function evaluations in 30 iterations. Compared with the FDK algorithm with 364 projections, the GPBB-SFE algorithm produces visibly equivalent quality CBCT image for the head-and-neck patient with only 180 projections, in 131.7 s, further supporting its clinical applicability.

  5. Optical recognition of statistical patterns

    NASA Astrophysics Data System (ADS)

    Lee, S. H.

    1981-12-01

    Optical implementation of the Fukunaga-Koontz transform (FKT) and the Least-Squares Linear Mapping Technique (LSLMT) is described. The FKT is a linear transformation which performs image feature extraction for a two-class image classification problem. The LSLMT performs a transform from large dimensional feature space to small dimensional decision space for separating multiple image classes by maximizing the interclass differences while minimizing the intraclass variations. The FKT and the LSLMT were optically implemented by utilizing a coded phase optical processor. The transform was used for classifying birds and fish. After the F-K basis functions were calculated, those most useful for classification were incorporated into a computer generated hologram. The output of the optical processor, consisting of the squared magnitude of the F-K coefficients, was detected by a T.V. camera, digitized, and fed into a micro-computer for classification. A simple linear classifier based on only two F-K coefficients was able to separate the images into two classes, indicating that the F-K transform had chosen good features. Two advantages of optically implementing the FKT and LSLMT are parallel and real time processing.

  6. Optical recognition of statistical patterns

    NASA Technical Reports Server (NTRS)

    Lee, S. H.

    1981-01-01

    Optical implementation of the Fukunaga-Koontz transform (FKT) and the Least-Squares Linear Mapping Technique (LSLMT) is described. The FKT is a linear transformation which performs image feature extraction for a two-class image classification problem. The LSLMT performs a transform from large dimensional feature space to small dimensional decision space for separating multiple image classes by maximizing the interclass differences while minimizing the intraclass variations. The FKT and the LSLMT were optically implemented by utilizing a coded phase optical processor. The transform was used for classifying birds and fish. After the F-K basis functions were calculated, those most useful for classification were incorporated into a computer generated hologram. The output of the optical processor, consisting of the squared magnitude of the F-K coefficients, was detected by a T.V. camera, digitized, and fed into a micro-computer for classification. A simple linear classifier based on only two F-K coefficients was able to separate the images into two classes, indicating that the F-K transform had chosen good features. Two advantages of optically implementing the FKT and LSLMT are parallel and real time processing.

  7. Sampling limits for electron tomography with sparsity-exploiting reconstructions.

    PubMed

    Jiang, Yi; Padgett, Elliot; Hovden, Robert; Muller, David A

    2018-03-01

    Electron tomography (ET) has become a standard technique for 3D characterization of materials at the nano-scale. Traditional reconstruction algorithms such as weighted back projection suffer from disruptive artifacts with insufficient projections. Popularized by compressed sensing, sparsity-exploiting algorithms have been applied to experimental ET data and show promise for improving reconstruction quality or reducing the total beam dose applied to a specimen. Nevertheless, theoretical bounds for these methods have been less explored in the context of ET applications. Here, we perform numerical simulations to investigate performance of ℓ 1 -norm and total-variation (TV) minimization under various imaging conditions. From 36,100 different simulated structures, our results show specimens with more complex structures generally require more projections for exact reconstruction. However, once sufficient data is acquired, dividing the beam dose over more projections provides no improvements-analogous to the traditional dose-fraction theorem. Moreover, a limited tilt range of ±75° or less can result in distorting artifacts in sparsity-exploiting reconstructions. The influence of optimization parameters on reconstructions is also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. A spatially adaptive total variation regularization method for electrical resistance tomography

    NASA Astrophysics Data System (ADS)

    Song, Xizi; Xu, Yanbin; Dong, Feng

    2015-12-01

    The total variation (TV) regularization method has been used to solve the ill-posed inverse problem of electrical resistance tomography (ERT), owing to its good ability to preserve edges. However, the quality of the reconstructed images, especially in the flat region, is often degraded by noise. To optimize the regularization term and the regularization factor according to the spatial feature and to improve the resolution of reconstructed images, a spatially adaptive total variation (SATV) regularization method is proposed. A kind of effective spatial feature indicator named difference curvature is used to identify which region is a flat or edge region. According to different spatial features, the SATV regularization method can automatically adjust both the regularization term and regularization factor. At edge regions, the regularization term is approximate to the TV functional to preserve the edges; in flat regions, it is approximate to the first-order Tikhonov (FOT) functional to make the solution stable. Meanwhile, the adaptive regularization factor determined by the spatial feature is used to constrain the regularization strength of the SATV regularization method for different regions. Besides, a numerical scheme is adopted for the implementation of the second derivatives of difference curvature to improve the numerical stability. Several reconstruction image metrics are used to quantitatively evaluate the performance of the reconstructed results. Both simulation and experimental results indicate that, compared with the TV (mean relative error 0.288, mean correlation coefficient 0.627) and FOT (mean relative error 0.295, mean correlation coefficient 0.638) regularization methods, the proposed SATV (mean relative error 0.259, mean correlation coefficient 0.738) regularization method can endure a relatively high level of noise and improve the resolution of reconstructed images.

  9. Respiratory motion correction in 4D-PET by simultaneous motion estimation and image reconstruction (SMEIR)

    PubMed Central

    Kalantari, Faraz; Li, Tianfang; Jin, Mingwu; Wang, Jing

    2016-01-01

    In conventional 4D positron emission tomography (4D-PET), images from different frames are reconstructed individually and aligned by registration methods. Two issues that arise with this approach are as follows: 1) the reconstruction algorithms do not make full use of projection statistics; and 2) the registration between noisy images can result in poor alignment. In this study, we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) methods for motion estimation/correction in 4D-PET. A modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM-TV) was used to obtain a primary motion-compensated PET (pmc-PET) from all projection data, using Demons derived deformation vector fields (DVFs) as initial motion vectors. A motion model update was performed to obtain an optimal set of DVFs in the pmc-PET and other phases, by matching the forward projection of the deformed pmc-PET with measured projections from other phases. The OSEM-TV image reconstruction was repeated using updated DVFs, and new DVFs were estimated based on updated images. A 4D-XCAT phantom with typical FDG biodistribution was generated to evaluate the performance of the SMEIR algorithm in lung and liver tumors with different contrasts and different diameters (10 to 40 mm). The image quality of the 4D-PET was greatly improved by the SMEIR algorithm. When all projections were used to reconstruct 3D-PET without motion compensation, motion blurring artifacts were present, leading up to 150% tumor size overestimation and significant quantitative errors, including 50% underestimation of tumor contrast and 59% underestimation of tumor uptake. Errors were reduced to less than 10% in most images by using the SMEIR algorithm, showing its potential in motion estimation/correction in 4D-PET. PMID:27385378

  10. Respiratory motion correction in 4D-PET by simultaneous motion estimation and image reconstruction (SMEIR)

    NASA Astrophysics Data System (ADS)

    Kalantari, Faraz; Li, Tianfang; Jin, Mingwu; Wang, Jing

    2016-08-01

    In conventional 4D positron emission tomography (4D-PET), images from different frames are reconstructed individually and aligned by registration methods. Two issues that arise with this approach are as follows: (1) the reconstruction algorithms do not make full use of projection statistics; and (2) the registration between noisy images can result in poor alignment. In this study, we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) methods for motion estimation/correction in 4D-PET. A modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM-TV) was used to obtain a primary motion-compensated PET (pmc-PET) from all projection data, using Demons derived deformation vector fields (DVFs) as initial motion vectors. A motion model update was performed to obtain an optimal set of DVFs in the pmc-PET and other phases, by matching the forward projection of the deformed pmc-PET with measured projections from other phases. The OSEM-TV image reconstruction was repeated using updated DVFs, and new DVFs were estimated based on updated images. A 4D-XCAT phantom with typical FDG biodistribution was generated to evaluate the performance of the SMEIR algorithm in lung and liver tumors with different contrasts and different diameters (10-40 mm). The image quality of the 4D-PET was greatly improved by the SMEIR algorithm. When all projections were used to reconstruct 3D-PET without motion compensation, motion blurring artifacts were present, leading up to 150% tumor size overestimation and significant quantitative errors, including 50% underestimation of tumor contrast and 59% underestimation of tumor uptake. Errors were reduced to less than 10% in most images by using the SMEIR algorithm, showing its potential in motion estimation/correction in 4D-PET.

  11. Expanding Dimensionality in Cinema Color: Impacting Observer Metamerism through Multiprimary Display

    NASA Astrophysics Data System (ADS)

    Long, David L.

    Television and cinema display are both trending towards greater ranges and saturation of reproduced colors made possible by near-monochromatic RGB illumination technologies. Through current broadcast and digital cinema standards work, system designs employing laser light sources, narrow-band LED, quantum dots and others are being actively endorsed in promotion of Wide Color Gamut (WCG). Despite artistic benefits brought to creative content producers, spectrally selective excitations of naturally different human color response functions exacerbate variability of observer experience. An exaggerated variation in color-sensing is explicitly counter to the exhaustive controls and calibrations employed in modern motion picture pipelines. Further, singular standard observer summaries of human color vision such as found in the CIE's 1931 and 1964 color matching functions and used extensively in motion picture color management are deficient in recognizing expected human vision variability. Many researchers have confirmed the magnitude of observer metamerism in color matching in both uniform colors and imagery but few have shown explicit color management with an aim of minimized difference in observer perception variability. This research shows that not only can observer metamerism influences be quantitatively predicted and confirmed psychophysically but that intentionally engineered multiprimary displays employing more than three primaries can offer increased color gamut with drastically improved consistency of experience. To this end, a seven-channel prototype display has been constructed based on observer metamerism models and color difference indices derived from the latest color vision demographic research. This display has been further proven in forced-choice paired comparison tests to deliver superior color matching to reference stimuli versus both contemporary standard RGB cinema projection and recently ratified standard laser projection across a large population of color-normal observers.

  12. A feature alignment score for online cone-beam CT-based image-guided radiotherapy for prostate cancer.

    PubMed

    Hargrave, Catriona; Deegan, Timothy; Poulsen, Michael; Bednarz, Tomasz; Harden, Fiona; Mengersen, Kerrie

    2018-05-17

    To develop a method for scoring online cone-beam CT (CBCT)-to-planning CT image feature alignment to inform prostate image-guided radiotherapy (IGRT) decision-making. The feasibility of incorporating volume variation metric thresholds predictive of delivering planned dose into weighted functions, was investigated. Radiation therapists and radiation oncologists participated in workshops where they reviewed prostate CBCT-IGRT case examples and completed a paper-based survey of image feature matching practices. For 36 prostate cancer patients, one daily CBCT was retrospectively contoured then registered with their plan to simulate delivered dose if (a) no online setup corrections and (b) online image alignment and setup corrections, were performed. Survey results were used to select variables for inclusion in classification and regression tree (CART) and boosted regression trees (BRT) modeling of volume variation metric thresholds predictive of delivering planned dose to the prostate, proximal seminal vesicles (PSV), bladder, and rectum. Weighted functions incorporating the CART and BRT results were used to calculate a score of individual tumor and organ at risk image feature alignment (FAS TV _ OAR ). Scaled and weighted FAS TV _ OAR were then used to calculate a score of overall treatment compliance (FAS global ) for a given CBCT-planning CT registration. The FAS TV _ OAR were assessed for sensitivity, specificity, and predictive power. FAS global thresholds indicative of high, medium, or low overall treatment plan compliance were determined using coefficients from multiple linear regression analysis. Thirty-two participants completed the prostate CBCT-IGRT survey. While responses demonstrated consensus of practice for preferential ranking of planning CT and CBCT match features in the presence of deformation and rotation, variation existed in the specified thresholds for observed volume differences requiring patient repositioning or repeat bladder and bowel preparation. The CART and BRT modeling indicated that for a given registration, a Dice similarity coefficient >0.80 and >0.60 for the prostate and PSV, respectively, and a maximum Hausdorff distance <8.0 mm for both structures were predictive of delivered dose ± 5% of planned dose. A normalized volume difference <1.0 and a CBCT anterior rectum wall >1.0 mm anterior to the planning CT anterior rectum wall were predictive of delivered dose >5% of planned rectum dose. A normalized volume difference <0.88, and a CBCT bladder wall >13.5 mm inferior and >5.0 mm posterior to the planning CT bladder were predictive of delivered dose >5% of planned bladder dose. A FAS TV _ OAR >0 is indicative of delivery of planned dose. For calculated FAS TV _ OAR for the prostate, PSV, bladder, and rectum using test data, sensitivity was 0.56, 0.75, 0.89, and 1.00, respectively; specificity 0.90, 0.94, 0.59, and 1.00, respectively; positive predictive power 0.90, 0.86, 0.53, and 1.00, respectively; and negative predictive power 0.56, 0.89, 0.91, and 1.00, respectively. Thresholds for the calculated FAS global of were low <60, medium 60-80, and high >80, with a 27% misclassification rate for the test data. A FAS global incorporating nested FAS TV _ OAR and volume variation metric thresholds predictive of treatment plan compliance was developed, offering an alternative to pretreatment dose calculations to assess treatment delivery accuracy. © 2018 American Association of Physicists in Medicine.

  13. Results of TV imaging of Phobos - Experiment VSK-Fregat

    NASA Technical Reports Server (NTRS)

    Avanesov, G.; Zhukov, B.; Ziman, IA.; Kostenko, V.; Kuz'min, A.; Duxbury, T.

    1991-01-01

    From February to March 1989 the Phobos 2 spacecraft took 37 TV images of Phobos at a distance of 190-1100 km. These images complement Mariner-9 and Viking data by providing higher-resolution coverage of a laarge region west of the crater Stickney (40-160 deg W) and by providing disk-resolved measurements of surface brightness at a greater range of wavelengths and additional phase angles. These images have supported updated mapping and characterization of large craters and grooves, and have provided additional observations of craters' and grooves' bright rims. Variations in surface visible/near-infrared color ratio of almost a factor of 2 have been recognized; these variations appear to be associated with the ejecta of specific large impact craters. Updated determinations of satellite mass and volume allow calculation of a more accurate value of bulk density, 1.90 + or - 0.1 g/cu cm. This is sigificantly lower than the density of meteoritic analogs to Phobos' surface, suggesting a porous interior perhaps containing interstitial ice.

  14. Image superresolution by midfrequency sparse representation and total variation regularization

    NASA Astrophysics Data System (ADS)

    Xu, Jian; Chang, Zhiguo; Fan, Jiulun; Zhao, Xiaoqiang; Wu, Xiaomin; Wang, Yanzi

    2015-01-01

    Machine learning has provided many good tools for superresolution, whereas existing methods still need to be improved in many aspects. On one hand, the memory and time cost should be reduced. On the other hand, the step edges of the results obtained by the existing methods are not clear enough. We do the following work. First, we propose a method to extract the midfrequency features for dictionary learning. This method brings the benefit of a reduction of the memory and time complexity without sacrificing the performance. Second, we propose a detailed wiping-off total variation (DWO-TV) regularization model to reconstruct the sharp step edges. This model adds a novel constraint on the downsampling version of the high-resolution image to wipe off the details and artifacts and sharpen the step edges. Finally, step edges produced by the DWO-TV regularization and the details provided by learning are fused. Experimental results show that the proposed method offers a desirable compromise between low time and memory cost and the reconstruction quality.

  15. Noisy image magnification with total variation regularization and order-changed dictionary learning

    NASA Astrophysics Data System (ADS)

    Xu, Jian; Chang, Zhiguo; Fan, Jiulun; Zhao, Xiaoqiang; Wu, Xiaomin; Wang, Yanzi

    2015-12-01

    Noisy low resolution (LR) images are always obtained in real applications, but many existing image magnification algorithms can not get good result from a noisy LR image. We propose a two-step image magnification algorithm to solve this problem. The proposed algorithm takes the advantages of both regularization-based method and learning-based method. The first step is based on total variation (TV) regularization and the second step is based on sparse representation. In the first step, we add a constraint on the TV regularization model to magnify the LR image and at the same time to suppress the noise in it. In the second step, we propose an order-changed dictionary training algorithm to train the dictionaries which is dominated by texture details. Experimental results demonstrate that the proposed algorithm performs better than many other algorithms when the noise is not serious. The proposed algorithm can also provide better visual quality on natural LR images.

  16. A feasibility study of the provision of a personalized interdisciplinary audiovisual summary to facilitate care transfer care at hospital discharge: Care Transfer Video (CareTV).

    PubMed

    Newnham, Harvey H; Gibbs, Harry H; Ritchie, Edward S; Hitchcock, Karen I; Nagalingam, Vathy; Hoiles, Andrew; Wallace, Ed; Georgeson, Elizabeth; Holton, Sara

    2015-04-01

    To assess the feasibility and patient acceptance of a personalized interdisciplinary audiovisual record to facilitate effective communication with patients, family, carers and other healthcare workers at hospital discharge. Descriptive pilot study utilizing a study-specific patient feedback questionnaire conducted from October 2013 to June 2014. Twenty General Medical inpatients being discharged from an Acute General Medical Ward in a metropolitan teaching hospital. Audiovisual record of a CareTV filmed at the patient's bedside by a consultant-led interdisciplinary team, within 24 h prior to discharge from the ward, provided immediately for the patient to take home. Patient surveys were completed within 2 weeks of discharge. Technical quality, utilization, acceptability, patient satisfaction and recall of diagnosis, medication changes and post-discharge review arrangements. All patients had watched their CareTV either alone or in the presence of a variety of others: close family, their GP, a medical specialist, friends or other health personnel. Participating patients had good understanding of the video content and recall of their diagnosis, medication changes and post-discharge plans. Patient feedback was overwhelmingly positive. In the context of a General Medical Unit with extensive experience in interdisciplinary bedside rounding and teamwork, CareTV is simple to implement, inexpensive, technically feasible, requires minimal staff training and is acceptable to patients. The results of this pilot study will inform and indicate the feasibility of conducting a larger randomized control trial of the impact of CareTV on patient satisfaction, medication adherence and recall of key information, and primary healthcare provider satisfaction. © The Author 2015. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  17. Relationships between in vivo dynamic knee joint loading, static alignment and tibial subchondral bone microarchitecture in end-stage knee osteoarthritis.

    PubMed

    Roberts, B C; Solomon, L B; Mercer, G; Reynolds, K J; Thewlis, D; Perilli, E

    2018-04-01

    To study, in end-stage knee osteoarthritis (OA) patients, relationships between indices of in vivo dynamic knee joint loads obtained pre-operatively using gait analysis, static knee alignment, and the subchondral trabecular bone (STB) microarchitecture of their excised tibial plateau quantified with 3D micro-CT. Twenty-five knee OA patients scheduled for total knee arthroplasty underwent pre-operative gait analysis. Mechanical axis deviation (MAD) was determined radiographically. Following surgery, excised tibial plateaus were micro-CT-scanned and STB microarchitecture analysed in four subregions (anteromedial, posteromedial, anterolateral, posterolateral). Regional differences in STB microarchitecture and relationships between joint loading and microarchitecture were examined. STB microarchitecture differed among subregions (P < 0.001), anteromedially exhibiting highest bone volume fraction (BV/TV) and lowest structure model index (SMI). Anteromedial BV/TV and SMI correlated strongest with the peak external rotation moment (ERM; r = -0.74, r = 0.67, P < 0.01), despite ERM being the lowest (by factor of 10) of the moments considered, with majority of ERM measures below accuracy thresholds; medial-to-lateral BV/TV ratios correlated with ERM, MAD, knee adduction moment (KAM) and internal rotation moment (|r|-range: 0.54-0.74). When controlling for walking speed, KAM and MAD, the ERM explained additional 11-30% of the variations in anteromedial BV/TV and medial-to-lateral BV/TV ratio (R 2  = 0.59, R 2  = 0.69, P < 0.01). This preliminary study suggests significant associations between tibial plateau STB microarchitecture and knee joint loading indices in end-stage knee OA patients. Particularly, anteromedial BV/TV correlates strongest with ERM, whereas medial-to-lateral BV/TV ratio correlates strongest with indicators of medial-to-lateral joint loading (MAD, KAM) and rotational moments. However, associations with ERM should be interpreted with caution. Copyright © 2018 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  18. Prioritizing the Components of Vulnerability: A Genetic Algorithm Minimization of Flood Risk

    NASA Astrophysics Data System (ADS)

    Bongolan, Vena Pearl; Ballesteros, Florencio; Baritua, Karessa Alexandra; Junne Santos, Marie

    2013-04-01

    We define a flood resistant city as an optimal arrangement of communities according to their traits, with the goal of minimizing the flooding vulnerability via a genetic algorithm. We prioritize the different components of flooding vulnerability, giving each component a weight, thus expressing vulnerability as a weighted sum. This serves as the fitness function for the genetic algorithm. We also allowed non-linear interactions among related but independent components, viz, poverty and mortality rate, and literacy and radio/ tv penetration. The designs produced reflect the relative importance of the components, and we observed a synchronicity between the interacting components, giving us a more consistent design.

  19. Low-illumination image denoising method for wide-area search of nighttime sea surface

    NASA Astrophysics Data System (ADS)

    Song, Ming-zhu; Qu, Hong-song; Zhang, Gui-xiang; Tao, Shu-ping; Jin, Guang

    2018-05-01

    In order to suppress complex mixing noise in low-illumination images for wide-area search of nighttime sea surface, a model based on total variation (TV) and split Bregman is proposed in this paper. A fidelity term based on L1 norm and a fidelity term based on L2 norm are designed considering the difference between various noise types, and the regularization mixed first-order TV and second-order TV are designed to balance the influence of details information such as texture and edge for sea surface image. The final detection result is obtained by using the high-frequency component solved from L1 norm and the low-frequency component solved from L2 norm through wavelet transform. The experimental results show that the proposed denoising model has perfect denoising performance for artificially degraded and low-illumination images, and the result of image quality assessment index for the denoising image is superior to that of the contrastive models.

  20. A guide to reading health care news stories.

    PubMed

    Schwitzer, Gary

    2014-07-01

    From April 16, 2006, through May 30, 2013, a team of reviewers from HealthNewsReview.org, many of whom were physicians, evaluated the reporting by US news organizations on new medical treatments, tests, products, and procedures. After reviewing 1889 stories (approximately 43% newspaper articles, 30% wire or news services stories, 15% online pieces [including those by broadcast and magazine companies], and 12% network television stories), the reviewers graded most stories unsatisfactory on 5 of 10 review criteria: costs, benefits, harms, quality of the evidence, and comparison of the new approach with alternatives. Drugs, medical devices, and other interventions were usually portrayed positively; potential harms were minimized, and costs were ignored. Our findings can help journalists improve their news stories and help physicians and the public better understand the strengths and weaknesses of news media coverage of medical and health topics.

  1. Influence of viewing distance and size of tv on visual fatigue and feeling of involvement.

    PubMed

    Sakamoto, Kiyomi; Asahara, Shigeo; Yamashita, Kuniko; Okada, Akira

    2012-12-01

    Using physiological and psychological measurements, we carried out experiments to investigate the influence of viewing distance and TV screen size on visual fatigue and feeling of involvement using 17-inch, 42-inch and 65-inch displays. The experiment was an ordinary viewing test with the content similar to everyday TV programs for one hour including scenery, sport, drama, etc., with commercials sandwiched in between. The number of participants was 16 (8 persons aged 21-31, and 8 persons aged 50-70) for each display size. In all, 48 participants viewed 3 display sizes. In our physiological evaluation, CFF (critical flicker fusion frequency), blink rate and a sympathetic nerve activity index were used; and in the psychological evaluation, questionnaires and interviews were employed. Our results, based on physiological and psychological measurements, suggest the opti- mum viewing distance to be around 165-220 cm, irrespective of screen size. Our evaluations, which are based on optimum viewing distance for minimal visual fatigue and a closer feeling of involvement, might therefore not agree with the currently recommended viewing distance, which is defined as 2 or 3 times the display's height.

  2. Preferred color correction for digital LCD TVs

    NASA Astrophysics Data System (ADS)

    Kim, Kyoung Tae; Kim, Choon-Woo; Ahn, Ji-Young; Kang, Dong-Woo; Shin, Hyun-Ho

    2009-01-01

    Instead of colorimetirc color reproduction, preferred color correction is applied for digital TVs to improve subjective image quality. First step of the preferred color correction is to survey the preferred color coordinates of memory colors. This can be achieved by the off-line human visual tests. Next step is to extract pixels of memory colors representing skin, grass and sky. For the detected pixels, colors are shifted towards the desired coordinates identified in advance. This correction process may result in undesirable contours on the boundaries between the corrected and un-corrected areas. For digital TV applications, the process of extraction and correction should be applied in every frame of the moving images. This paper presents a preferred color correction method in LCH color space. Values of chroma and hue are corrected independently. Undesirable contours on the boundaries of correction are minimized. The proposed method change the coordinates of memory color pixels towards the target color coordinates. Amount of correction is determined based on the averaged coordinate of the extracted pixels. The proposed method maintains the relative color difference within memory color areas. Performance of the proposed method is evaluated using the paired comparison. Results of experiments indicate that the proposed method can reproduce perceptually pleasing images to viewers.

  3. [Nutritional health messages transmitted through television advertising. Trends and errors].

    PubMed

    Ortega, R M; Andrés, P; Jiménez, L M; Ortega, A

    1995-01-01

    The present study analyzes de publicity messages with a alimentary-nutritional content (n = 448), aired by 2 television channels (one public and one private), during 6 hours a day in the first week of October 1993, examining the most frequent tendencies and errors, and whether or not they are adhering to the nutritional standards intended to improve the health of the population. With this aim, a questionnaire was designed, which was submitted to a control prior to doing the study, and which permitted the same study during the years 1991, 1992, and 1993. The message which was most used to promote the sales of the products, was the taste, followed by quality, novelty, health, nutritional and natural. The messages indicating that the product reduces or minimizes fat, cholesterol, sodium, sugar, alcohol, ... are few or lower than those observed in other populations. In some cases the messages may be useful in re-enforcing the standards of the nutritional educators and health care professionals who try to improve the diet and the health of the public. However, in the majority of cases, the message of the advertisements may mislead or confuse the consumer with irrelevant or incomplete information. They also frequently contribute to the promotion of an extremely thin body image, which guides the food choice of a large percentage of the population. The results of the study may help in the planning of nutritional education of the population, and they emphasize the need for a greater supervision and control of the advertisements.

  4. Low-dose X-ray computed tomography image reconstruction with a combined low-mAs and sparse-view protocol

    PubMed Central

    Gao, Yang; Bian, Zhaoying; Huang, Jing; Zhang, Yunwan; Niu, Shanzhou; Feng, Qianjin; Chen, Wufan; Liang, Zhengrong; Ma, Jianhua

    2014-01-01

    To realize low-dose imaging in X-ray computed tomography (CT) examination, lowering milliampere-seconds (low-mAs) or reducing the required number of projection views (sparse-view) per rotation around the body has been widely studied as an easy and effective approach. In this study, we are focusing on low-dose CT image reconstruction from the sinograms acquired with a combined low-mAs and sparse-view protocol and propose a two-step image reconstruction strategy. Specifically, to suppress significant statistical noise in the noisy and insufficient sinograms, an adaptive sinogram restoration (ASR) method is first proposed with consideration of the statistical property of sinogram data, and then to further acquire a high-quality image, a total variation based projection onto convex sets (TV-POCS) method is adopted with a slight modification. For simplicity, the present reconstruction strategy was termed as “ASR-TV-POCS.” To evaluate the present ASR-TV-POCS method, both qualitative and quantitative studies were performed on a physical phantom. Experimental results have demonstrated that the present ASR-TV-POCS method can achieve promising gains over other existing methods in terms of the noise reduction, contrast-to-noise ratio, and edge detail preservation. PMID:24977611

  5. Convex composite wavelet frame and total variation-based image deblurring using nonconvex penalty functions

    NASA Astrophysics Data System (ADS)

    Shen, Zhengwei; Cheng, Lishuang

    2017-09-01

    Total variation (TV)-based image deblurring method can bring on staircase artifacts in the homogenous region of the latent images recovered from the degraded images while a wavelet/frame-based image deblurring method will lead to spurious noise spikes and pseudo-Gibbs artifacts in the vicinity of discontinuities of the latent images. To suppress these artifacts efficiently, we propose a nonconvex composite wavelet/frame and TV-based image deblurring model. In this model, the wavelet/frame and the TV-based methods may complement each other, which are verified by theoretical analysis and experimental results. To further improve the quality of the latent images, nonconvex penalty function is used to be the regularization terms of the model, which may induce a stronger sparse solution and will more accurately estimate the relative large gradient or wavelet/frame coefficients of the latent images. In addition, by choosing a suitable parameter to the nonconvex penalty function, the subproblem that splits by the alternative direction method of multipliers algorithm from the proposed model can be guaranteed to be a convex optimization problem; hence, each subproblem can converge to a global optimum. The mean doubly augmented Lagrangian and the isotropic split Bregman algorithms are used to solve these convex subproblems where the designed proximal operator is used to reduce the computational complexity of the algorithms. Extensive numerical experiments indicate that the proposed model and algorithms are comparable to other state-of-the-art model and methods.

  6. Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy

    NASA Astrophysics Data System (ADS)

    Han, Xiao; Pearson, Erik; Pelizzari, Charles; Al-Hallaq, Hania; Sidky, Emil Y.; Bian, Junguo; Pan, Xiaochuan

    2015-06-01

    Kilo-voltage (KV) cone-beam computed tomography (CBCT) unit mounted onto a linear accelerator treatment system, often referred to as on-board imager (OBI), plays an increasingly important role in image-guided radiation therapy. While the FDK algorithm is currently used for reconstructing images from clinical OBI data, optimization-based reconstruction has also been investigated for OBI CBCT. An optimization-based reconstruction involves numerous parameters, which can significantly impact reconstruction properties (or utility). The success of an optimization-based reconstruction for a particular class of practical applications thus relies strongly on appropriate selection of parameter values. In the work, we focus on tailoring the constrained-TV-minimization-based reconstruction, an optimization-based reconstruction previously shown of some potential for CBCT imaging conditions of practical interest, to OBI imaging through appropriate selection of parameter values. In particular, for given real data of phantoms and patient collected with OBI CBCT, we first devise utility metrics specific to OBI-quality-assurance tasks and then apply them to guiding the selection of parameter values in constrained-TV-minimization-based reconstruction. The study results show that the reconstructions are with improvement, relative to clinical FDK reconstruction, in both visualization and quantitative assessments in terms of the devised utility metrics.

  7. Design of a model observer to evaluate calcification detectability in breast tomosynthesis and application to smoothing prior optimization.

    PubMed

    Michielsen, Koen; Nuyts, Johan; Cockmartin, Lesley; Marshall, Nicholas; Bosmans, Hilde

    2016-12-01

    In this work, the authors design and validate a model observer that can detect groups of microcalcifications in a four-alternative forced choice experiment and use it to optimize a smoothing prior for detectability of microcalcifications. A channelized Hotelling observer (CHO) with eight Laguerre-Gauss channels was designed to detect groups of five microcalcifications in a background of acrylic spheres by adding the CHO log-likelihood ratios calculated at the expected locations of the five calcifications. This model observer is then applied to optimize the detectability of the microcalcifications as a function of the smoothing prior. The authors examine the quadratic and total variation (TV) priors, and a combination of both. A selection of these reconstructions was then evaluated by human observers to validate the correct working of the model observer. The authors found a clear maximum for the detectability of microcalcification when using the total variation prior with weight β TV = 35. Detectability only varied over a small range for the quadratic and combined quadratic-TV priors when weight β Q of the quadratic prior was changed by two orders of magnitude. Spearman correlation with human observers was good except for the highest value of β for the quadratic and TV priors. Excluding those, the authors found ρ = 0.93 when comparing detection fractions, and ρ = 0.86 for the fitted detection threshold diameter. The authors successfully designed a model observer that was able to predict human performance over a large range of settings of the smoothing prior, except for the highest values of β which were outside the useful range for good image quality. Since detectability only depends weakly on the strength of the combined prior, it is not possible to pick an optimal smoothness based only on this criterion. On the other hand, such choice can now be made based on other criteria without worrying about calcification detectability.

  8. Spatial Pyramid Covariance based Compact Video Code for Robust Face Retrieval in TV-series.

    PubMed

    Li, Yan; Wang, Ruiping; Cui, Zhen; Shan, Shiguang; Chen, Xilin

    2016-10-10

    We address the problem of face video retrieval in TV-series which searches video clips based on the presence of specific character, given one face track of his/her. This is tremendously challenging because on one hand, faces in TV-series are captured in largely uncontrolled conditions with complex appearance variations, and on the other hand retrieval task typically needs efficient representation with low time and space complexity. To handle this problem, we propose a compact and discriminative representation for the huge body of video data, named Compact Video Code (CVC). Our method first models the face track by its sample (i.e., frame) covariance matrix to capture the video data variations in a statistical manner. To incorporate discriminative information and obtain more compact video signature suitable for retrieval, the high-dimensional covariance representation is further encoded as a much lower-dimensional binary vector, which finally yields the proposed CVC. Specifically, each bit of the code, i.e., each dimension of the binary vector, is produced via supervised learning in a max margin framework, which aims to make a balance between the discriminability and stability of the code. Besides, we further extend the descriptive granularity of covariance matrix from traditional pixel-level to more general patchlevel, and proceed to propose a novel hierarchical video representation named Spatial Pyramid Covariance (SPC) along with a fast calculation method. Face retrieval experiments on two challenging TV-series video databases, i.e., the Big Bang Theory and Prison Break, demonstrate the competitiveness of the proposed CVC over state-of-the-art retrieval methods. In addition, as a general video matching algorithm, CVC is also evaluated in traditional video face recognition task on a standard Internet database, i.e., YouTube Celebrities, showing its quite promising performance by using an extremely compact code with only 128 bits.

  9. Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR)

    PubMed Central

    Shieh, Chun-Chien; Kipritidis, John; O’Brien, Ricky T; Cooper, Benjamin J; Kuncic, Zdenka; Keall, Paul J

    2015-01-01

    Total-variation (TV) minimization reconstructions can significantly reduce noise and streaks in thoracic four-dimensional cone-beam computed tomography (4D CBCT) images compared to the Feldkamp-Davis-Kress (FDK) algorithm currently used in practice. TV minimization reconstructions are, however, prone to over-smoothing anatomical details and are also computationally inefficient. The aim of this study is to demonstrate a proof of concept that these disadvantages can be overcome by incorporating the general knowledge of the thoracic anatomy via anatomy segmentation into the reconstruction. The proposed method, referred as the anatomical-adaptive image regularization (AAIR) method, utilizes the adaptive-steepest-descent projection-onto-convex-sets (ASD-POCS) framework, but introduces an additional anatomy segmentation step in every iteration. The anatomy segmentation information is implemented in the reconstruction using a heuristic approach to adaptively suppress over-smoothing at anatomical structures of interest. The performance of AAIR depends on parameters describing the weighting of the anatomy segmentation prior and segmentation threshold values. A sensitivity study revealed that the reconstruction outcome is not sensitive to these parameters as long as they are chosen within a suitable range. AAIR was validated using a digital phantom and a patient scan, and was compared to FDK, ASD-POCS, and the prior image constrained compressed sensing (PICCS) method. For the phantom case, AAIR reconstruction was quantitatively shown to be the most accurate as indicated by the mean absolute difference and the structural similarity index. For the patient case, AAIR resulted in the highest signal-to-noise ratio (i.e. the lowest level of noise and streaking) and the highest contrast-to-noise ratios for the tumor and the bony anatomy (i.e. the best visibility of anatomical details). Overall, AAIR was much less prone to over-smoothing anatomical details compared to ASD-POCS, and did not suffer from residual noise/streaking and motion blur migrated from the prior image as in PICCS. AAIR was also found to be more computationally efficient than both ASD-POCS and PICCS, with a reduction in computation time of over 50% compared to ASD-POCS. The use of anatomy segmentation was, for the first time, demonstrated to significantly improve image quality and computational efficiency for thoracic 4D CBCT reconstruction. Further developments are required to facilitate AAIR for practical use. PMID:25565244

  10. Can even minimal news coverage influence consumer health-related behaviour? A case study of iodized salt sales, Australia.

    PubMed

    Li, Mu; Chapman, Simon; Agho, Kingsley; Eastman, Creswell J

    2008-06-01

    Lack of iodine in the diet can cause a spectrum of conditions, known as iodine deficiency disorders (IDD). While iodized salt has been retailed in Australia since the 1960s, sales have remained low, at approximately 10% of total edible salt sales. Salt has never been promoted, advertised or discounted by retailers or manufacturers. Extensive news coverage of health issues has often been shown to influence consumer behaviour. But can even modest news coverage generate changes in consumer health-related behaviour? We report a significant increase (5.2%) in national iodized salt sales after a brief period of television and newspaper reports about IDD and the benefits of using iodized salt during and after the Australian National Iodine Nutrition Study in 2003 and 2004. We conclude that even brief news media exposure can influence health-related decisions.

  11. Interactive display of molecular models using a microcomputer system

    NASA Technical Reports Server (NTRS)

    Egan, J. T.; Macelroy, R. D.

    1980-01-01

    A simple, microcomputer-based, interactive graphics display system has been developed for the presentation of perspective views of wire frame molecular models. The display system is based on a TERAK 8510a graphics computer system with a display unit consisting of microprocessor, television display and keyboard subsystems. The operating system includes a screen editor, file manager, PASCAL and BASIC compilers and command options for linking and executing programs. The graphics program, written in USCD PASCAL, involves the centering of the coordinate system, the transformation of centered model coordinates into homogeneous coordinates, the construction of a viewing transformation matrix to operate on the coordinates, clipping invisible points, perspective transformation and scaling to screen coordinates; commands available include ZOOM, ROTATE, RESET, and CHANGEVIEW. Data file structure was chosen to minimize the amount of disk storage space. Despite the inherent slowness of the system, its low cost and flexibility suggests general applicability.

  12. 76 FR 72849 - Digital Low Power Television, Television Translator, and Television Booster Stations and To Amend...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-28

    ...] Digital Low Power Television, Television Translator, and Television Booster Stations and To Amend Rules... for Digital Low Power Television, Television Translator, and Television Booster Stations and to Amend... television, TV translator, and Class A television station DTV licensees''). The Commission has also revised...

  13. 47 CFR 73.3521 - Mutually exclusive applications for low power television, television translators and television...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... television, television translators and television booster stations. 73.3521 Section 73.3521 Telecommunication..., television translators and television booster stations. When there is a pending application for a new low power television, television translator, or television booster station, or for major changes in an...

  14. 47 CFR 73.3521 - Mutually exclusive applications for low power television, television translators and television...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... television, television translators and television booster stations. 73.3521 Section 73.3521 Telecommunication..., television translators and television booster stations. When there is a pending application for a new low power television, television translator, or television booster station, or for major changes in an...

  15. 47 CFR 73.3521 - Mutually exclusive applications for low power television, television translators and television...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... television, television translators and television booster stations. 73.3521 Section 73.3521 Telecommunication..., television translators and television booster stations. When there is a pending application for a new low power television, television translator, or television booster station, or for major changes in an...

  16. 47 CFR 73.3521 - Mutually exclusive applications for low power television, television translators and television...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... television, television translators and television booster stations. 73.3521 Section 73.3521 Telecommunication..., television translators and television booster stations. When there is a pending application for a new low power television, television translator, or television booster station, or for major changes in an...

  17. 47 CFR 73.3521 - Mutually exclusive applications for low power television, television translators and television...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... television, television translators and television booster stations. 73.3521 Section 73.3521 Telecommunication..., television translators and television booster stations. When there is a pending application for a new low power television, television translator, or television booster station, or for major changes in an...

  18. The magic of image processing

    NASA Astrophysics Data System (ADS)

    Sulentic, Jack W.; Lorre, Jean J.

    1984-05-01

    Digital technology has been used to improve enhancement techniques in astronomical image processing. Continuous tone variations in photographs are assigned density number (DN) values which are arranged in an array. DN locations are processed by computer and turned into pixels which form a reconstruction of the original scene on a television monitor. Digitized data can be manipulated to enhance contrast and filter out gross patterns of light and dark which obscure small scale features. Separate black and white frames exposed at different wavelengths can be digitized and processed individually, then recombined to produce a final image in color. Several examples of the use of the technique are provided, including photographs of spiral galaxy M33; four galaxies in Coma Berenices (NGC 4169, 4173, 4174, and 4175); and Stephens Quintet.

  19. Applied photo interpretation for airbrush cartography

    NASA Technical Reports Server (NTRS)

    Inge, J. L.; Bridges, P. M.

    1976-01-01

    New techniques of cartographic portrayal have been developed for the compilation of maps of lunar and planetary surfaces. Conventional photo interpretation methods utilizing size, shape, shadow, tone, pattern, and texture are applied to computer processed satellite television images. The variety of the image data allows the illustrator to interpret image details by inter-comparison and intra-comparison of photographs. Comparative judgements are affected by illumination, resolution, variations in surface coloration, and transmission or processing artifacts. The validity of the interpretation process is tested by making a representational drawing by an airbrush portrayal technique. Production controls insure the consistency of a map series. Photo interpretive cartographic portrayal skills are used to prepare two kinds of map series and are adaptable to map products of different kinds and purposes.

  20. Mars atmospheric opacity effects observed in the Northern Hemisphere by Viking orbiter imaging

    NASA Technical Reports Server (NTRS)

    Thorpe, T. E.

    1981-01-01

    Viking orbiter television camera observations of Mars contrasts show variations of atmospheric opacity in the Southern Hemisphere. The study is extended into the Northern Hemisphere, over a longer time period, and results in a detailed description of photometric changes at the lander sites, as seen from orbit. During the period of January 1977 to April 1978, a series of four storms at 202 deg, 264 deg, 40 deg and 86 deg latitudes have provided photometric changes and planetwide aerosol distributions for 18 months. It is found that the large, forward-scattering particles did not enter the atmosphere at the storm's onsets. A reduction of atmospheric transmission by over 20% at visual wavelengths remained for nearly one Martian year.

  1. Variable features on Mars - Preliminary Mariner 9 television results.

    NASA Technical Reports Server (NTRS)

    Sagan, C.; Veverka, J.; Fox, P.; Dubisch, R.; Lederberg, J.; Levinthal, E.; Quam, L.; Tucker, R.; Pollack, J. B.; Smith, B. A.

    1972-01-01

    Systematic Mariner 9 photography of a range of Martian surface features, observed with all three photometric angles approximately invariant, reveals three general categories of albedo variations: (1) an essentially uniform contrast enhancement due to the dissipation of the dust storm; (2) the appearance of splotches, irregular dark markings at least partially related to topography; and (3) the development of both bright and dark linear streaks, generally emanating from craters. Some splotches and streaks vary on characteristic timescales of about two weeks; they have characteristic dimensions of kilometers to tens of kilometers. The morphology and variability of streaks and splotches, and the resolution of at least one splotch into an extensive dune system, implicate windblown dust as the principal agent of Martian albedo differences and variability.

  2. CNV-TV: a robust method to discover copy number variation from short sequencing reads.

    PubMed

    Duan, Junbo; Zhang, Ji-Gang; Deng, Hong-Wen; Wang, Yu-Ping

    2013-05-02

    Copy number variation (CNV) is an important structural variation (SV) in human genome. Various studies have shown that CNVs are associated with complex diseases. Traditional CNV detection methods such as fluorescence in situ hybridization (FISH) and array comparative genomic hybridization (aCGH) suffer from low resolution. The next generation sequencing (NGS) technique promises a higher resolution detection of CNVs and several methods were recently proposed for realizing such a promise. However, the performances of these methods are not robust under some conditions, e.g., some of them may fail to detect CNVs of short sizes. There has been a strong demand for reliable detection of CNVs from high resolution NGS data. A novel and robust method to detect CNV from short sequencing reads is proposed in this study. The detection of CNV is modeled as a change-point detection from the read depth (RD) signal derived from the NGS, which is fitted with a total variation (TV) penalized least squares model. The performance (e.g., sensitivity and specificity) of the proposed approach are evaluated by comparison with several recently published methods on both simulated and real data from the 1000 Genomes Project. The experimental results showed that both the true positive rate and false positive rate of the proposed detection method do not change significantly for CNVs with different copy numbers and lengthes, when compared with several existing methods. Therefore, our proposed approach results in a more reliable detection of CNVs than the existing methods.

  3. 76 FR 11680 - Digital Low Power Television, Television Translator, and Television Booster Stations and Digital...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-03

    ...] Digital Low Power Television, Television Translator, and Television Booster Stations and Digital Class A... Commission's Rules to Establish Rules for Digital Low Power, Television Translator, and Television Booster... Digital Low Power Television Translator, Television Booster Stations, and to Amend Rules for Digital Class...

  4. Structured Sparse Principal Components Analysis With the TV-Elastic Net Penalty.

    PubMed

    de Pierrefeu, Amicie; Lofstedt, Tommy; Hadj-Selem, Fouad; Dubois, Mathieu; Jardri, Renaud; Fovet, Thomas; Ciuciu, Philippe; Frouin, Vincent; Duchesnay, Edouard

    2018-02-01

    Principal component analysis (PCA) is an exploratory tool widely used in data analysis to uncover the dominant patterns of variability within a population. Despite its ability to represent a data set in a low-dimensional space, PCA's interpretability remains limited. Indeed, the components produced by PCA are often noisy or exhibit no visually meaningful patterns. Furthermore, the fact that the components are usually non-sparse may also impede interpretation, unless arbitrary thresholding is applied. However, in neuroimaging, it is essential to uncover clinically interpretable phenotypic markers that would account for the main variability in the brain images of a population. Recently, some alternatives to the standard PCA approach, such as sparse PCA (SPCA), have been proposed, their aim being to limit the density of the components. Nonetheless, sparsity alone does not entirely solve the interpretability problem in neuroimaging, since it may yield scattered and unstable components. We hypothesized that the incorporation of prior information regarding the structure of the data may lead to improved relevance and interpretability of brain patterns. We therefore present a simple extension of the popular PCA framework that adds structured sparsity penalties on the loading vectors in order to identify the few stable regions in the brain images that capture most of the variability. Such structured sparsity can be obtained by combining, e.g., and total variation (TV) penalties, where the TV regularization encodes information on the underlying structure of the data. This paper presents the structured SPCA (denoted SPCA-TV) optimization framework and its resolution. We demonstrate SPCA-TV's effectiveness and versatility on three different data sets. It can be applied to any kind of structured data, such as, e.g., -dimensional array images or meshes of cortical surfaces. The gains of SPCA-TV over unstructured approaches (such as SPCA and ElasticNet PCA) or structured approach (such as GraphNet PCA) are significant, since SPCA-TV reveals the variability within a data set in the form of intelligible brain patterns that are easier to interpret and more stable across different samples.

  5. Hard-to-reach? Using health access status as a way to more effectively target segments of the Latino audience.

    PubMed

    Wilkin, Holley A; Ball-Rokeach, Sandra J

    2011-04-01

    Health issues disproportionately affect Latinos, but variations within this ethnic group may mean that some Latinos are harder to reach with health messages than others. This paper introduces a methodology grounded in communication infrastructure theory to better target 'hard-to-reach' audiences. A random digit dialing telephone survey of 739 Latinos living in two Los Angeles communities was conducted. The relationships between health access difficulties and connections to an integrated storytelling network as well as individual health communication source connections were explored. Findings suggest that Latinos who are connected to an integrated storytelling network report marginally greater ease finding healthcare, despite not being any more likely to have insurance or a regular place for healthcare. Latinos who have health access problems tended to rely more upon Spanish-language television for health information. In addition, those without healthcare access problems are more likely to indicate that they use health professionals, the Internet, mainstream TV and printed materials like health pamphlets for health information. The theoretical and methodological contributions of this work, its major findings, implications, limitations and policy guidelines are discussed.

  6. Alcohol brand use of youth-appealing advertising and consumption by youth and adults.

    PubMed

    Padon, Alisa A; Rimal, Rajiv N; Siegel, Michael; DeJong, William; Naimi, Timothy S; JernFigan, David H

    2018-02-05

    Youth exposure to alcohol marketing has been shown to be an important contributor to the problem of underage drinking in the U.S. More work is needed on identifying and minimizing content with particular appeal to youth. We tested the association between the youth-appeal of marketing content of televised alcohol advertisements and the brand-specific alcohol consumption of both underage youth and adults. We used existing data from three sources: a brand-specific alcohol consumption survey among underage youth ( N =1032), a brand-specific alcohol consumption survey among adults ( N ~13,000), and an analysis of content appealing to youth (CAY) in a sample of televised alcohol advertisements ( n =96) aired during the youth survey. The association between CAY scores for the 96 alcohol ads and youth (age 13-20) versus adult (age 21+) consumption of those ads' brands was tested through bivariate and multivariate models. Brand CAY scores were (a) positively associated with brand-specific youth consumption after controlling for adult brand consumption; (b) positively associated with a ratio of youth-toadult brand-specific consumption; and (c) not associated with adult brand consumption. Alcohol brands with youth-appealing advertising are consumed more often by youth than adults, indicating that these ads may be more persuasive to relatively younger audiences, and that youth are not simply mirroring adult consumption patterns in their choice of brands. Future research should consider the content of alcohol advertising when testing marketing effects on youth drinking, and surveillance efforts might focus on brands popular among youth.

  7. Stimulus Set Meaningfulness and Neurophysiological Differentiation: A Functional Magnetic Resonance Imaging Study

    PubMed Central

    Boly, Melanie; Sasai, Shuntaro; Gosseries, Olivia; Oizumi, Masafumi; Casali, Adenauer; Massimini, Marcello; Tononi, Giulio

    2015-01-01

    A meaningful set of stimuli, such as a sequence of frames from a movie, triggers a set of different experiences. By contrast, a meaningless set of stimuli, such as a sequence of ‘TV noise’ frames, triggers always the same experience—of seeing ‘TV noise’—even though the stimuli themselves are as different from each other as the movie frames. We reasoned that the differentiation of cortical responses underlying the subject’s experiences, as measured by Lempel-Ziv complexity (incompressibility) of functional MRI images, should reflect the overall meaningfulness of a set of stimuli for the subject, rather than differences among the stimuli. We tested this hypothesis by quantifying the differentiation of brain activity patterns in response to a movie sequence, to the same movie scrambled in time, and to ‘TV noise’, where the pixels from each movie frame were scrambled in space. While overall cortical activation was strong and widespread in all conditions, the differentiation (Lempel-Ziv complexity) of brain activation patterns was correlated with the meaningfulness of the stimulus set, being highest in the movie condition, intermediate in the scrambled movie condition, and minimal for ‘TV noise’. Stimulus set meaningfulness was also associated with higher information integration among cortical regions. These results suggest that the differentiation of neural responses can be used to assess the meaningfulness of a given set of stimuli for a given subject, without the need to identify the features and categories that are relevant to the subject, nor the precise location of selective neural responses. PMID:25970444

  8. The broadcast of shared attention and its impact on political persuasion.

    PubMed

    Shteynberg, Garriy; Bramlett, James M; Fles, Elizabeth H; Cameron, Jaclyn

    2016-11-01

    In democracies where multitudes yield political influence, so does broadcast media that reaches those multitudes. However, broadcast media may not be powerful simply because it reaches a certain audience, but because each of the recipients is aware of that fact. That is, watching broadcast media can evoke a state of shared attention, or the perception of simultaneous coattention with others. Whereas past research has investigated the effects of shared attention with a few socially close others (i.e., friends, acquaintances, minimal ingroup members), we examine the impact of shared attention with a multitude of unfamiliar others in the context of televised broadcasting. In this paper, we explore whether shared attention increases the psychological impact of televised political speeches, and whether fewer numbers of coattending others diminishes this effect. Five studies investigate whether the perception of simultaneous coattention, or shared attention, on a mass broadcasted political speech leads to more extreme judgments. The results indicate that the perception of synchronous coattention (as compared with coattending asynchronously and attending alone) renders persuasive speeches more persuasive, and unpersuasive speeches more unpersuasive. We also find that recall memory for the content of the speech mediates the effect of shared attention on political persuasion. The results are consistent with the notion that shared attention on mass broadcasted information results in deeper processing of the content, rendering judgments more extreme. In all, our findings imply that shared attention is a cognitive capacity that supports large-scale social coordination, where multitudes of people can cognitively prioritize simultaneously coattended information. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  9. Blind beam-hardening correction from Poisson measurements

    NASA Astrophysics Data System (ADS)

    Gu, Renliang; Dogandžić, Aleksandar

    2016-02-01

    We develop a sparse image reconstruction method for Poisson-distributed polychromatic X-ray computed tomography (CT) measurements under the blind scenario where the material of the inspected object and the incident energy spectrum are unknown. We employ our mass-attenuation spectrum parameterization of the noiseless measurements and express the mass- attenuation spectrum as a linear combination of B-spline basis functions of order one. A block coordinate-descent algorithm is developed for constrained minimization of a penalized Poisson negative log-likelihood (NLL) cost function, where constraints and penalty terms ensure nonnegativity of the spline coefficients and nonnegativity and sparsity of the density map image; the image sparsity is imposed using a convex total-variation (TV) norm penalty term. This algorithm alternates between a Nesterov's proximal-gradient (NPG) step for estimating the density map image and a limited-memory Broyden-Fletcher-Goldfarb-Shanno with box constraints (L-BFGS-B) step for estimating the incident-spectrum parameters. To accelerate convergence of the density- map NPG steps, we apply function restart and a step-size selection scheme that accounts for varying local Lipschitz constants of the Poisson NLL. Real X-ray CT reconstruction examples demonstrate the performance of the proposed scheme.

  10. Potential of Proton Therapy to Reduce Acute Hematologic Toxicity in Concurrent Chemoradiation Therapy for Esophageal Cancer.

    PubMed

    Warren, Samantha; Hurt, Christopher N; Crosby, Thomas; Partridge, Mike; Hawkins, Maria A

    2017-11-01

    Radiation therapy dose escalation using a simultaneous integrated boost (SIB) is predicted to improve local tumor control in esophageal cancer; however, any increase in acute hematologic toxicity (HT) could limit the predicted improvement in patient outcomes. Proton therapy has been shown to significantly reduce HT in lung cancer patients receiving concurrent chemotherapy. Therefore, we investigated the potential of bone marrow sparing with protons for esophageal tumors. Twenty-one patients with mid-esophageal cancer who had undergone conformal radiation therapy (3D50) were selected. Two surrogates for bone marrow were created by outlining the thoracic bones (bone) and only the body of the thoracic vertebrae (TV) in Eclipse. The percentage of overlap of the TV with the planning treatment volume was recorded for each patient. Additional plans were created retrospectively, including a volumetric modulated arc therapy (VMAT) plan with the same dose as for 3D50; a VMAT SIB plan with a dose prescription of 62.5 Gy to the high-risk subregion within the planning treatment volume; a reoptimized TV-sparing VMAT plan; and a proton therapy plan with the same SIB dose prescription. The bone and TV dose metrics were recorded and compared across all plans and variations with respect to PTV and percentage of overlap for each patient. The 3D50 plans showed the highest bone mean dose and TV percentage of volume receiving ≥30 Gy (V 30Gy ) for each patient. The VMAT plans irradiated a larger bone V 10Gy than did the 3D50 plans. The reoptimized VMAT62.5 VT plans showed improved sparing of the TV volume, but only the proton plans showed significant sparing for bone V 10Gy and bone mean dose, especially for patients with a larger PTV. The results of the present study have shown that proton therapy can reduced bone marrow toxicity. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Geostatistics as a tool to improve the natural background level definition: An application in groundwater.

    PubMed

    Dalla Libera, Nico; Fabbri, Paolo; Mason, Leonardo; Piccinini, Leonardo; Pola, Marco

    2017-11-15

    The Natural Background Level (NBL), suggested by UE BRIDGE project, is suited for spatially distributed datasets providing a regional value that could be higher than the Threshold Value (TV) set by every country. In hydro-geochemically dis-homogeneous areas, the use of a unique regional NBL, higher than TV, could arise problems to distinguish between natural occurrences and anthropogenic contaminant sources. Hence, the goal of this study is to improve the NBL definition employing a geostatistical approach, which reconstructs the contaminant spatial structure accounting geochemical and hydrogeological relationships. This integrated mapping is fundamental to evaluate the contaminant's distribution impact on the NBL, giving indications to improve it. We decided to test this method on the Drainage Basin of Venice Lagoon (DBVL, NE Italy), where the existing NBL is seven times higher than the TV. This area is notoriously affected by naturally occurring arsenic contamination. An available geochemical dataset collected by 50 piezometers was used to reconstruct the spatial distribution of arsenic in the densely populated area of the DBVL. A cokriging approach was applied exploiting the geochemical relationships among As, Fe and NH4+. The obtained spatial predictions of arsenic concentrations were divided into three different zones: i) areas with an As concentration lower than the TV, ii) areas with an As concentration between the TV and the median of the values higher than the TV, and iii) areas with an As concentration higher than the median. Following the BRIDGE suggestions, where enough samples were available, the 90th percentile for each zone was calculated to obtain a local NBL (LNBL). Differently from the original NBL, this local value gives more detailed water quality information accounting the hydrogeological and geochemical setting, and contaminant spatial variation. Hence, the LNBL could give more indications about the distinction between natural occurrence and anthropogenic contamination. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Minimal Absent Words in Four Human Genome Assemblies

    PubMed Central

    Garcia, Sara P.; Pinho, Armando J.

    2011-01-01

    Minimal absent words have been computed in genomes of organisms from all domains of life. Here, we aim to contribute to the catalogue of human genomic variation by investigating the variation in number and content of minimal absent words within a species, using four human genome assemblies. We compare the reference human genome GRCh37 assembly, the HuRef assembly of the genome of Craig Venter, the NA12878 assembly from cell line GM12878, and the YH assembly of the genome of a Han Chinese individual. We find the variation in number and content of minimal absent words between assemblies more significant for large and very large minimal absent words, where the biases of sequencing and assembly methodologies become more pronounced. Moreover, we find generally greater similarity between the human genome assemblies sequenced with capillary-based technologies (GRCh37 and HuRef) than between the human genome assemblies sequenced with massively parallel technologies (NA12878 and YH). Finally, as expected, we find the overall variation in number and content of minimal absent words within a species to be generally smaller than the variation between species. PMID:22220210

  13. The interaction of acoustic and linguistic grouping cues in auditory object formation

    NASA Astrophysics Data System (ADS)

    Shapley, Kathy; Carrell, Thomas

    2005-09-01

    One of the earliest explanations for good speech intelligibility in poor listening situations was context [Miller et al., J. Exp. Psychol. 41 (1951)]. Context presumably allows listeners to group and predict speech appropriately and is known as a top-down listening strategy. Amplitude comodulation is another mechanism that has been shown to improve sentence intelligibility. Amplitude comodulation provides acoustic grouping information without changing the linguistic content of the desired signal [Carrell and Opie, Percept. Psychophys. 52 (1992); Hu and Wang, Proceedings of ICASSP-02 (2002)] and is considered a bottom-up process. The present experiment investigated how amplitude comodulation and semantic information combined to improve speech intelligibility. Sentences with high- and low-predictability word sequences [Boothroyd and Nittrouer, J. Acoust. Soc. Am. 84 (1988)] were constructed in two different formats: time-varying sinusoidal sentences (TVS) and reduced-channel sentences (RC). The stimuli were chosen because they minimally represent the traditionally defined speech cues and therefore emphasized the importance of the high-level context effects and low-level acoustic grouping cues. Results indicated that semantic information did not influence intelligibility levels of TVS and RC sentences. In addition amplitude modulation aided listeners' intelligibility scores in the TVS condition but hindered listeners' intelligibility scores in the RC condition.

  14. Heritability of Lumbar Trabecular Bone Mechanical Properties in Baboons

    PubMed Central

    Havill, L.M.; Allen, M.R.; Bredbenner, T.L.; Burr, D.B.; Nicolella, D.P.; Turner, C.H.; Warren, D.M.; Mahaney, M.C.

    2010-01-01

    Genetic effects on mechanical properties have been demonstrated in rodents, but not confirmed in primates. Our aim was to quantify the proportion of variation in vertebral trabecular bone mechanical properties that is due to the effects of genes. L3 vertebrae were collected from 110 females and 46 male baboons (6–32 years old) from a single extended pedigree. Cranio-caudally oriented trabecular bone cores were scanned with microCT then tested in monotonic compression to determine apparent ultimate stress, modulus, and toughness. Age and sex effects and heritability (h2) were assessed using maximum likelihood-based variance components methods. Additive effects of genes on residual trait variance were significant for ultimate stress (h2=0.58), toughness (h2=0.64), and BV/TV (h2=0.55). When BV/TV was accounted for, the residual variance in ultimate stress accounted for by the additive effects of genes was no longer significant. Toughness, however, showed evidence of a non-BV/TV-related genetic effect. Overall, maximum stress and modulus show strong genetic effects that are nearly entirely due to bone volume. Toughness shows strong genetic effects related to bone volume and shows additional genetic effects (accounting for 10% of the total trait variance) that are independent of bone volume. These results support continued use of bone volume as a focal trait to identify genes related to skeletal fragility, but also show that other focal traits related to toughness and variation in the organic component of bone matrix will enhance our ability to find additional genes that are particularly relevant to fatigue-related fractures. PMID:19900599

  15. An evaluation of a mass media campaign to encourage parents of adolescents to talk to their children about sex.

    PubMed

    DuRant, Robert H; Wolfson, Mark; LaFrance, Betty; Balkrishnan, Rajesh; Altman, David

    2006-03-01

    We evaluated a mass media campaign in North Carolina that used television (TV) public service announcements (PSAs), radio PSAs, and billboards to encourage parents of adolescents to talk to their children about sex. The primary message of the campaign was "Talk to your kids about sex. Everyone else is." Thirty-two of the 100 counties in North Carolina were chosen to evaluate the mass media campaign. Paid TV PSAs were aired in 22 of these counties, radio PSAs were aired in 21 counties, and billboards were displayed in 6 counties over a period of 9 months. The counties in our sample varied from no exposure to exposure to all 3 types of media. To assess the impact of the campaign, a sample of 1,132 parents of adolescents living in the 32 counties was administered a postexposure survey via a telephone interview. Questions about exposure to the media campaign were embedded among questions concerning media exposure to other health-related messages. The parent survey assessed the frequency the parents reported exposure to each type of media message, correct knowledge of the message, and multiple item scales that assessed how often they had talked to their child about various issues related to sex during the previous 6 months, intentions to talk to their child about these issues during the next month, and attitudes about discussing sexual issues with their child. In bivariate analyses the levels of parental exposure to the 3 types of media messages were associated with both having talked to their children and intentions to talk to their children about sex (p < .0001). When analyzed with multiple regression, female gender, minority ethnicity, frequency of seeing a billboard on teenage pregnancy, frequency of seeing a TV PSA about sex, and frequency of hearing a radio PSA about sex and teenage pregnancy accounted for 12.8% (p < .0001) of the variance in having talked to their child about sex. Female gender, minority ethnicity, and previously talking to their child about sex accounted for 9.9% of the variation in positive communication attitudes about sex. Positive communication attitudes, female parent, minority ethnicity, frequency of seeing a billboard about sex, frequency of seeing a TV PSA about sex, and frequency of hearing radio PSAs about sex accounted for 12.3% of the variation in parental intentions to talk to their child about sex during the next month. Exposure to each component of this mass media campaign was associated with parents recently having talked to their adolescent children about sex and intentions to talk to their children during the next month.

  16. Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Ho; Xing Lei; Lee, Rena

    2012-05-15

    Purpose: X-ray scatter incurred to detectors degrades the quality of cone-beam computed tomography (CBCT) and represents a problem in volumetric image guided and adaptive radiation therapy. Several methods using a beam blocker for the estimation and subtraction of scatter have been proposed. However, due to missing information resulting from the obstruction of the blocker, such methods require dual scanning or dynamically moving blocker to obtain a complete volumetric image. Here, we propose a half beam blocker-based approach, in conjunction with a total variation (TV) regularized Feldkamp-Davis-Kress (FDK) algorithm, to correct scatter-induced artifacts by simultaneously acquiring image and scatter information frommore » a single-rotation CBCT scan. Methods: A half beam blocker, comprising lead strips, is used to simultaneously acquire image data on one side of the projection data and scatter data on the other half side. One-dimensional cubic B-Spline interpolation/extrapolation is applied to derive patient specific scatter information by using the scatter distributions on strips. The estimated scatter is subtracted from the projection image acquired at the opposite view. With scatter-corrected projections where this subtraction is completed, the FDK algorithm based on a cosine weighting function is performed to reconstruct CBCT volume. To suppress the noise in the reconstructed CBCT images produced by geometric errors between two opposed projections and interpolated scatter information, total variation regularization is applied by a minimization using a steepest gradient descent optimization method. The experimental studies using Catphan504 and anthropomorphic phantoms were carried out to evaluate the performance of the proposed scheme. Results: The scatter-induced shading artifacts were markedly suppressed in CBCT using the proposed scheme. Compared with CBCT without a blocker, the nonuniformity value was reduced from 39.3% to 3.1%. The root mean square error relative to values inside the regions of interest selected from a benchmark scatter free image was reduced from 50 to 11.3. The TV regularization also led to a better contrast-to-noise ratio. Conclusions: An asymmetric half beam blocker-based FDK acquisition and reconstruction technique has been established. The proposed scheme enables simultaneous detection of patient specific scatter and complete volumetric CBCT reconstruction without additional requirements such as prior images, dual scans, or moving strips.« less

  17. 47 CFR 74.789 - Broadcast regulations applicable to digital low power television and television translator stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... power television and television translator stations. 74.789 Section 74.789 Telecommunication FEDERAL... AND OTHER PROGRAM DISTRIBUTIONAL SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.789 Broadcast regulations applicable to digital low power television and television translator...

  18. Regularization Parameter Selection for Nonlinear Iterative Image Restoration and MRI Reconstruction Using GCV and SURE-Based Methods

    PubMed Central

    Ramani, Sathish; Liu, Zhihao; Rosen, Jeffrey; Nielsen, Jon-Fredrik; Fessler, Jeffrey A.

    2012-01-01

    Regularized iterative reconstruction algorithms for imaging inverse problems require selection of appropriate regularization parameter values. We focus on the challenging problem of tuning regularization parameters for nonlinear algorithms for the case of additive (possibly complex) Gaussian noise. Generalized cross-validation (GCV) and (weighted) mean-squared error (MSE) approaches (based on Stein's Unbiased Risk Estimate— SURE) need the Jacobian matrix of the nonlinear reconstruction operator (representative of the iterative algorithm) with respect to the data. We derive the desired Jacobian matrix for two types of nonlinear iterative algorithms: a fast variant of the standard iterative reweighted least-squares method and the contemporary split-Bregman algorithm, both of which can accommodate a wide variety of analysis- and synthesis-type regularizers. The proposed approach iteratively computes two weighted SURE-type measures: Predicted-SURE and Projected-SURE (that require knowledge of noise variance σ2), and GCV (that does not need σ2) for these algorithms. We apply the methods to image restoration and to magnetic resonance image (MRI) reconstruction using total variation (TV) and an analysis-type ℓ1-regularization. We demonstrate through simulations and experiments with real data that minimizing Predicted-SURE and Projected-SURE consistently lead to near-MSE-optimal reconstructions. We also observed that minimizing GCV yields reconstruction results that are near-MSE-optimal for image restoration and slightly sub-optimal for MRI. Theoretical derivations in this work related to Jacobian matrix evaluations can be extended, in principle, to other types of regularizers and reconstruction algorithms. PMID:22531764

  19. Factors influencing the television viewing practices of Indian children.

    PubMed

    Ravikiran, S R; Baliga, B Shantharam; Jain, Animesh; Kotian, M Shashidhar

    2014-02-01

    To study the effect of socio-demographic factors, parental regulations and maternal television usage on the television viewing practices of Indian schoolchildren. Mothers of 6-12 y old children were interviewed using a pre-tested questionnaire at the pediatric outpatient. The television viewing practices of 405 schoolchildren with maternal television viewing and parental television rules were analyzed. Specific television viewing practices considered harmful in the present study were- viewing television >2 h, viewing television just prior to sleep (at bedtime), predominantly viewing general adult channels and using television as an aid to sleep. 35.8 % (n = 145) of the children viewed television for >2 h on schooldays. 20 % (n = 81) used television as sleep-aid. 28.1 % (n = 114) children had televisions in the room they slept. The frequency of parental television rules were with respect to: duration of viewing- 77.5 % (n = 314), timing of viewing- 63.7 % (n = 258), content- 35.6 % (n = 144). The children of families with the rule needing of parental permission to switch on the television [present in 34.8 % (n = 141) children] had lower harmful television viewing practices: duration of television viewing on schooldays >2 h (23.4 %, n = 33, P < 0.001); television viewed just before sleep (39 %, n = 55, P < 0.001); use of television as sleep-aid (12.1 %, n = 17, P = 0.003). 26.7 % (n = 108) of the mothers viewed television for >2 h. Linear regression analysis showed association between average television duration of children and average maternal television duration on schooldays (Beta = 0.246, t = 5.09, P < 0.001). Binary logistic regression analysis showed that harmful television viewing practices were significantly more in children with television in bedroom [OR = 7.49(4.19-13.38), P < 0.001]. It was reduced significantly by the parental rules on content viewed [OR = 0.41(0.23-0.72), P = 0.002]; need of permission to switch on television [OR = 0.31(0.18-0.53), P < 0.001] and a higher maternal education [OR = 0.29 (0.14-0.59), P = 0.001]. Lower maternal education, increased maternal television usage, presence of television in bedroom resulted in harmful television viewing practices among Indian children. The parental rules that were effective in countering these were the rule on content viewed and needing parental permission to switch on television.

  20. The Radial Variation of the Solar Wind Temperature-Speed Relationship

    NASA Astrophysics Data System (ADS)

    Elliott, H. A.; McComas, D. J.

    2010-12-01

    Generally, the solar wind temperature (T) and speed (V) are well correlated except in Interplanetary Coronal Mass Ejections where this correlation breaks down. We have shown that at 1 AU the speed-temperature relationship is often well represented by a linear fit for a speed range spanning both the slow and fast wind. By examining all of the ACE and OMNI measurements, we found that when coronal holes are large the fast wind can have a different T-V relationship than the slow wind. The best example of this was in 2003 when there was a very large and long-lived outward polarity coronal hole at low latitudes. The long-lived nature of the hole made it possible to clearly distinguish that large holes can have a different T-V relationship. We found it to be rare that holes are large enough and last long enough to have enough data points to clearly demonstrate this effect. In this study we compare the 2003 coronal hole observations from ACE with the Ulysses polar coronal hole measurements. In an even earlier ACE study we found that both the compressions and rarefactions curves are linear, but the compression curve is shifted to higher temperatures. In this presentation we use Helios, Ulysses, and ACE measurements to examine how the T-V relationship varies with distance. The dynamic evolution of the solar wind parameters is revealed when we first separate compressions and rarefactions and then determine the radial profiles of the solar wind parameters. We find that T-V relationship varies with distance and in particular beyond 3 AU the differences between the compressions and rarefactions are quite important and at such distances a simple linear fit does not represent the T-V distribution very well.

  1. Superiorized algorithm for reconstruction of CT images from sparse-view and limited-angle polyenergetic data

    NASA Astrophysics Data System (ADS)

    Humphries, T.; Winn, J.; Faridani, A.

    2017-08-01

    Recent work in CT image reconstruction has seen increasing interest in the use of total variation (TV) and related penalties to regularize problems involving reconstruction from undersampled or incomplete data. Superiorization is a recently proposed heuristic which provides an automatic procedure to ‘superiorize’ an iterative image reconstruction algorithm with respect to a chosen objective function, such as TV. Under certain conditions, the superiorized algorithm is guaranteed to find a solution that is as satisfactory as any found by the original algorithm with respect to satisfying the constraints of the problem; this solution is also expected to be superior with respect to the chosen objective. Most work on superiorization has used reconstruction algorithms which assume a linear measurement model, which in the case of CT corresponds to data generated from a monoenergetic x-ray beam. Many CT systems generate x-rays from a polyenergetic spectrum, however, in which the measured data represent an integral of object attenuation over all energies in the spectrum. This inconsistency with the linear model produces the well-known beam hardening artifacts, which impair analysis of CT images. In this work we superiorize an iterative algorithm for reconstruction from polyenergetic data, using both TV and an anisotropic TV (ATV) penalty. We apply the superiorized algorithm in numerical phantom experiments modeling both sparse-view and limited-angle scenarios. In our experiments, the superiorized algorithm successfully finds solutions which are as constraints-compatible as those found by the original algorithm, with significantly reduced TV and ATV values. The superiorized algorithm thus produces images with greatly reduced sparse-view and limited angle artifacts, which are also largely free of the beam hardening artifacts that would be present if a superiorized version of a monoenergetic algorithm were used.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, L; Han, Y; Jin, M

    Purpose: To develop an iterative reconstruction method for X-ray CT, in which the reconstruction can quickly converge to the desired solution with much reduced projection views. Methods: The reconstruction is formulated as a convex feasibility problem, i.e. the solution is an intersection of three convex sets: 1) data fidelity (DF) set – the L2 norm of the difference of observed projections and those from the reconstructed image is no greater than an error bound; 2) non-negativity of image voxels (NN) set; and 3) piecewise constant (PC) set - the total variation (TV) of the reconstructed image is no greater thanmore » an upper bound. The solution can be found by applying projection onto convex sets (POCS) sequentially for these three convex sets. Specifically, the algebraic reconstruction technique and setting negative voxels as zero are used for projection onto the DF and NN sets, respectively, while the projection onto the PC set is achieved by solving a standard Rudin, Osher, and Fatemi (ROF) model. The proposed method is named as full sequential POCS (FS-POCS), which is tested using the Shepp-Logan phantom and the Catphan600 phantom and compared with two similar algorithms, TV-POCS and CP-TV. Results: Using the Shepp-Logan phantom, the root mean square error (RMSE) of reconstructed images changing along with the number of iterations is used as the convergence measurement. In general, FS- POCS converges faster than TV-POCS and CP-TV, especially with fewer projection views. FS-POCS can also achieve accurate reconstruction of cone-beam CT of the Catphan600 phantom using only 54 views, comparable to that of FDK using 364 views. Conclusion: We developed an efficient iterative reconstruction for sparse-view CT using full sequential POCS. The simulation and physical phantom data demonstrated the computational efficiency and effectiveness of FS-POCS.« less

  3. Computed inverse resonance imaging for magnetic susceptibility map reconstruction.

    PubMed

    Chen, Zikuan; Calhoun, Vince

    2012-01-01

    This article reports a computed inverse magnetic resonance imaging (CIMRI) model for reconstructing the magnetic susceptibility source from MRI data using a 2-step computational approach. The forward T2*-weighted MRI (T2*MRI) process is broken down into 2 steps: (1) from magnetic susceptibility source to field map establishment via magnetization in the main field and (2) from field map to MR image formation by intravoxel dephasing average. The proposed CIMRI model includes 2 inverse steps to reverse the T2*MRI procedure: field map calculation from MR-phase image and susceptibility source calculation from the field map. The inverse step from field map to susceptibility map is a 3-dimensional ill-posed deconvolution problem, which can be solved with 3 kinds of approaches: the Tikhonov-regularized matrix inverse, inverse filtering with a truncated filter, and total variation (TV) iteration. By numerical simulation, we validate the CIMRI model by comparing the reconstructed susceptibility maps for a predefined susceptibility source. Numerical simulations of CIMRI show that the split Bregman TV iteration solver can reconstruct the susceptibility map from an MR-phase image with high fidelity (spatial correlation ≈ 0.99). The split Bregman TV iteration solver includes noise reduction, edge preservation, and image energy conservation. For applications to brain susceptibility reconstruction, it is important to calibrate the TV iteration program by selecting suitable values of the regularization parameter. The proposed CIMRI model can reconstruct the magnetic susceptibility source of T2*MRI by 2 computational steps: calculating the field map from the phase image and reconstructing the susceptibility map from the field map. The crux of CIMRI lies in an ill-posed 3-dimensional deconvolution problem, which can be effectively solved by the split Bregman TV iteration algorithm.

  4. Computed inverse MRI for magnetic susceptibility map reconstruction

    PubMed Central

    Chen, Zikuan; Calhoun, Vince

    2015-01-01

    Objective This paper reports on a computed inverse magnetic resonance imaging (CIMRI) model for reconstructing the magnetic susceptibility source from MRI data using a two-step computational approach. Methods The forward T2*-weighted MRI (T2*MRI) process is decomposed into two steps: 1) from magnetic susceptibility source to fieldmap establishment via magnetization in a main field, and 2) from fieldmap to MR image formation by intravoxel dephasing average. The proposed CIMRI model includes two inverse steps to reverse the T2*MRI procedure: fieldmap calculation from MR phase image and susceptibility source calculation from the fieldmap. The inverse step from fieldmap to susceptibility map is a 3D ill-posed deconvolution problem, which can be solved by three kinds of approaches: Tikhonov-regularized matrix inverse, inverse filtering with a truncated filter, and total variation (TV) iteration. By numerical simulation, we validate the CIMRI model by comparing the reconstructed susceptibility maps for a predefined susceptibility source. Results Numerical simulations of CIMRI show that the split Bregman TV iteration solver can reconstruct the susceptibility map from a MR phase image with high fidelity (spatial correlation≈0.99). The split Bregman TV iteration solver includes noise reduction, edge preservation, and image energy conservation. For applications to brain susceptibility reconstruction, it is important to calibrate the TV iteration program by selecting suitable values of the regularization parameter. Conclusions The proposed CIMRI model can reconstruct the magnetic susceptibility source of T2*MRI by two computational steps: calculating the fieldmap from the phase image and reconstructing the susceptibility map from the fieldmap. The crux of CIMRI lies in an ill-posed 3D deconvolution problem, which can be effectively solved by the split Bregman TV iteration algorithm. PMID:22446372

  5. The Impact of the Newer Television Technologies on Television Satisfaction.

    ERIC Educational Resources Information Center

    Perse, Elizabeth M.; Ferguson, Douglas A.

    1993-01-01

    Finds that use of new television technologies (cable television, videocassette recorders, and remote control devices) had an impact on receiving, pass-the-time, and companionship gratifications from television viewing. Shows that instrumental viewing motives, television exposure, and receiving informational gratifications from television viewing…

  6. [The evolution of surgical arthroscopy in Israel and worldwide].

    PubMed

    Haviv, Barak; Bronak, Shlomo; Thein, Rafael

    2015-04-01

    Arthroscopy is a minimal invasive surgical technique to treat joint disorders with the use of fiber optics for indirect vision and small surgical tools. The first endoscopic direct inspection of the knee joint was documented at the beginning of the 20th century; however, the clinical practice of arthroscopy started only fifty years later. The "historical fathers" of surgical arthroscopy were Kenji Takagi from Japan and Eugen Bircher from Switzerland. The arthroscopes had become safer and more dependable since the 1970's with the introduction of fiber optics, while vision became easier with the invention of television. Subsequently, in the 1980's and 90's instruments were refined and arthroscopy evolved from a diagnostic to a therapeutic tool with the advantages of minimal approach, few complications and short rehabilitation. The beginning of knee arthroscopy in Israel followed the development in North America in the1970's. Within a few years, knee arthroscopy in Israel had also evolved to be therapeutic rather than diagnostic and was specifically used for partial meniscectomies. Currently, arthroscopic surgery, particularly of the knee and shoulder, has become common practice worldwide. Arthroscopic procedures constitute more than a third of all orthopedic procedures performed at the Israeli Assuta private hospitals. With the development of various technologies, it is anticipated that arthroscopic techniques will further evolve and play an ever greater role in diagnosing and treating joint pathology.

  7. ILLINOIS JOURNAL OF EDUCATION--ILLINOIS SCHOOLS AND EDUCATIONAL TELEVISION.

    ERIC Educational Resources Information Center

    PAGE, RAY

    THIS PUBLICATION CONTAINS THIRTEEN ARTICLES ON THE USE OF EDUCATIONAL TELEVISION IN ILLINOIS. AMONG THE TOPICS COVERED ARE MULTICHANNEL MICROWAVE EDUCATIONAL TELEVISION, INNOVATIVE TELEVISION, OPEN- AND CLOSED-CIRCUIT TELEVISON, TELEVISION IN PSYCHOLOGY, AND STATE EDUCATIONAL TELEVISION LEGISLATION. THE USE OF THE TELEVISION MEDIUM IN VARIOUS…

  8. Television the Medium, the Message and Nutritional Health.

    ERIC Educational Resources Information Center

    Wadsworth, Laurie A.

    1996-01-01

    Presents a review of research linking nutritional health and body image attitudes with television viewing. Highlights include content analyses of advertisements and programming; audience uses of television; television as reality; socialization of attitudes and television; television, body image and self-esteem; television and health behaviors; and…

  9. 76 FR 46292 - Information Collections Being Reviewed by the Federal Communications Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-02

    ... Translator, and Television Booster Stations and to Amend Rules for Digital Class A Television Stations, MB... digital broadcasting and states that low power television, TV translator, and Class A television stations... Television, TV Translator and Class A Television Digital Transition Notifications; FCC Form 337. Form Number...

  10. 75 FR 64729 - Notice of Public Information Collection(s) Being Reviewed by the Federal Communications...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-20

    ... Rules to Establish Rules for Digital Low Power Television Translator, Television Booster Stations, and... power television (``LPTV'') and television translator (``TV translator'') stations and modifies certain... to this collection (namely, ``low power television, TV translator, and Class A television station DTV...

  11. The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.

    PubMed

    Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria

    2016-01-01

    A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of <1. 0m2, and 1.5 mm for a BSA of >1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no reoperations for TV insufficiency or stenosis. Reoperations on three patients (mean age 42.5 ± 8.7 years) were indicated for aortic valve replacement at 14 months postoperatively (n = 1) and for assist device implantation (n = 2) who eventually underwent heart transplant at 18 and 20 months after TV repair, respectively. The cumulative 12-year survival rate was 86.9%. This double-orifice technique is technically a straightforward repair to abolish TV incompetence with highly satisfactory results, particularly in patients with severe annular dilatation or with leaflet and chordal tethering. In the present series, the technique provided no pitfalls (if the location of the conduction system was borne in mind), requiring only a gentle placement of sutures. It also led to no residual regurgitation or reoperation during the follow up period.

  12. A fractional-N PLL with small ΔK vco wideband LC-VCO and current-matching CP for M-DTV systems

    NASA Astrophysics Data System (ADS)

    Gao, Haijun; Yan, Yuepeng; Du, Zhankun; Guo, Guiliang; Zeng, Longyue

    2011-06-01

    An Σ-Δ fractional-N frequency synthesiser with small K vco-variation wideband LC voltage controlled oscillator (LC-VCO) and current-matching charge pump (CP) for Mobile Digital television Systems is presented. To achieve small VCO-gain (K vco) variation, a parallel switched varactor array is proposed to the conventional wideband LC-VCO with switched capacitor array, the value of the switched varactor is pre-set and both arrays are controlled by the same switching code. Perfect current matching and good stability are obtained by the improved CP with an added bias branch circuit for low reference spur. The chip was fabricated in a Taiwan Semiconductor Manufacturing Company (TSMC) 0.25 µm complementary metal-oxide-semiconductor process and draws 12 mA from a 2.5 V supply voltage. The synthesiser covers a wide tuning range from 0.82 to 1.85 GHz with two integrated LC-VCOs, and each VCO achieves a K vco variation of less than 16% with a tuning range of more than 46%. The current mismatch of CP is as low as 1.2%. The measured close-in and out-of-band phase noise are -83.5 dBc/Hz@10 kHz and -127 dBc/Hz@1 MHz, respectively, the reference spur is -76.3 dBc.

  13. 76 FR 44821 - Digital Low Power Television, Television Translator, and Television Booster Stations and To Amend...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-27

    ...] Digital Low Power Television, Television Translator, and Television Booster Stations and To Amend Rules... this proceeding in order to allow a timely and successful completion of the low power television digital transition. Although Congress established a hard deadline of June 12, 2009 for full power stations...

  14. Total generalized variation-regularized variational model for single image dehazing

    NASA Astrophysics Data System (ADS)

    Shu, Qiao-Ling; Wu, Chuan-Sheng; Zhong, Qiu-Xiang; Liu, Ryan Wen

    2018-04-01

    Imaging quality is often significantly degraded under hazy weather condition. The purpose of this paper is to recover the latent sharp image from its hazy version. It is well known that the accurate estimation of depth information could assist in improving dehazing performance. In this paper, a detail-preserving variational model was proposed to simultaneously estimate haze-free image and depth map. In particular, the total variation (TV) and total generalized variation (TGV) regularizers were introduced to restrain haze-free image and depth map, respectively. The resulting nonsmooth optimization problem was efficiently solved using the alternating direction method of multipliers (ADMM). Comprehensive experiments have been conducted on realistic datasets to compare our proposed method with several state-of-the-art dehazing methods. Results have illustrated the superior performance of the proposed method in terms of visual quality evaluation.

  15. Relationship between parental estimate and an objective measure of child television watching

    PubMed Central

    Robinson, Jodie L; Winiewicz, Dana D; Fuerch, Janene H; Roemmich, James N; Epstein, Leonard H

    2006-01-01

    Many young children have televisions in their bedrooms, which may influence the relationship between parental estimate and objective measures of child television usage/week. Parental estimates of child television time of eighty 4–7 year old children (6.0 ± 1.2 years) at the 75th BMI percentile or greater (90.8 ± 6.8 BMI percentile) were compared to an objective measure of television time obtained from TV Allowance™ devices attached to every television in the home over a three week period. Results showed that parents overestimate their child's television time compared to an objective measure when no television is present in the bedroom by 4 hours/week (25.4 ± 11.5 vs. 21.4 ± 9.1) in comparison to underestimating television time by over 3 hours/week (26.5 ± 17.2 vs. 29.8 ± 14.4) when the child has a television in their bedroom (p = 0.02). Children with a television in their bedroom spend more objectively measured hours in television time than children without a television in their bedroom (29.8 ± 14.2 versus 21.4 ± 9.1, p = 0.003). Research on child television watching should take into account television watching in bedrooms, since it may not be adequately assessed by parental estimates. PMID:17129381

  16. 47 CFR 73.6019 - Digital Class A TV station protection of low power TV, TV translator, digital low power TV and...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... power TV, TV translator, digital low power TV and digital TV translator stations. 73.6019 Section 73... low power TV, TV translator, digital low power TV and digital TV translator stations. An application... A TV station will not be accepted if it fails to protect authorized low power TV, TV translator...

  17. 47 CFR 73.3572 - Processing of TV broadcast, Class A TV broadcast, low power TV, TV translators, and TV booster...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... broadcast, low power TV, TV translators, and TV booster applications. 73.3572 Section 73.3572..., low power TV, TV translators, and TV booster applications. (a) Applications for TV stations are..., TV translator, and TV booster stations authorized under part 74 of this chapter, a major change is...

  18. About Television.

    ERIC Educational Resources Information Center

    Mayer, Martin

    The entire broadcast television industry is the subject of this book. An attempt is made to present history, theory, and anecdotes about television programing, television advertising, television and politics, and network news, focusing all the while on American television, but with consideration given to alternative structures and methods.…

  19. The Vicissitudes of "Progressive Television."

    ERIC Educational Resources Information Center

    Ang, Ien

    This document analyzes and evaluates dilemmas and difficulties in developing/implementing "progressive television," a kind of television that seeks to transgress the boundaries of dominant (mainstream) television by proposing a new constellation of television production and consumption. The ideal is described as a television that tries…

  20. Mediators of the relationship between maternal education and children's TV viewing.

    PubMed

    Hesketh, Kylie; Ball, Kylie; Crawford, David; Campbell, Karen; Salmon, Jo

    2007-07-01

    Maternal education is consistently found to be inversely related to children's television viewing and is associated with aspects of the family television environment. This study investigates whether family television environment mediates the relationship between maternal education and children's television viewing. Parents of 1484 children reported maternal education, time their child spends watching television, and 21 aspects of the family television environment (potential mediators) during 2002 and 2003. Separate regression analyses were conducted in 2006 for each potential mediator that met two initial conditions for mediation (associated with both maternal education and children's television viewing (p<0.10)), to assess whether inclusion reduced the association between maternal education and children's television viewing. Multivariable regression assessed the combined impact of all mediators. Twelve of 21 potential mediators met the initial conditions for mediation. Inclusion of each resulted in decreased beta values (3.2% to 15.2%) for the association between maternal education and television viewing. Number and placement of televisions in the home appeared to have the greatest mediating effect, followed by frequency of eating dinner in front of the television with the child and rules about television viewing during mealtimes. Together, the 12 mediators accounted for more than one-third of the association between maternal education and children's television viewing time. This study suggests the strong inverse relationship between maternal education and children's television viewing is partly mediated by aspects of the family television environment.

  1. Reliability and validity of a brief questionnaire to assess television viewing and computer use by middle school children.

    PubMed

    Schmitz, Kathryn H; Harnack, Lisa; Fulton, Janet E; Jacobs, David R; Gao, Shujun; Lytle, Leslie A; Van Coevering, Pam

    2004-11-01

    Sedentary behaviors, like television viewing, are positively associated with overweight among young people. To monitor national health objectives for sedentary behaviors in young adolescents, this project developed and assessed the reliability and validity of a brief questionnaire to measure weekly television viewing, usual television viewing, and computer use by middle school children. Reliability and validity of the Youth Risk Behavior Survey (YRBS) question on weekday television viewing also were examined. A brief, five-item television and computer use questionnaire was completed twice by 245 middle school children with one week apart. To concurrently assess validity, students also completed television and computer use logs for seven days. Among all students, Spearman correlations for test-retest reliability for television viewing and computer use ranged from 0.55 to 0.68. Spearman correlations between the first questionnaire and the seven-day log produced the following results: YRBS question for weekday television viewing (0.46), weekend television viewing (0.37), average television viewing over the week (0.47), and computer use (0.39). Methods comparison analysis showed a mean difference (hours/week) between answers to questionnaire items and the log of -0.04 (1.70 standard deviation [SD]) hours for weekday television, -0.21 (2.54 SD) for weekend television, -0.09 (1.75 SD) for average television over the week, and 0.68 (1.26 SD) for computer use. The YRBS weekday television viewing question, and the newly developed questions to assess weekend television viewing, average television viewing, and computer use, produced adequate reliability and validity for surveillance of middle school students.

  2. The Future of Educational Television.

    ERIC Educational Resources Information Center

    Hudson, Robert B.

    In order to predict the future of educational television, the author discusses first instructional television, then public television, and also comments on the applications of communications satellites to television in both industrialized and developing nations. He predicts that in the future instructional television will be mainly carried by…

  3. 47 CFR 74.792 - Digital low power TV and TV translator station protected contour.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.792 Digital low power TV and TV... interference from other low power TV, TV translator, Class A TV or TV booster stations or digital low power TV...

  4. 47 CFR 74.792 - Digital low power TV and TV translator station protected contour.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.792 Digital low power TV and TV... interference from other low power TV, TV translator, Class A TV or TV booster stations or digital low power TV...

  5. 47 CFR 74.792 - Digital low power TV and TV translator station protected contour.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.792 Digital low power TV and TV... interference from other low power TV, TV translator, Class A TV or TV booster stations or digital low power TV...

  6. 47 CFR 74.792 - Digital low power TV and TV translator station protected contour.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.792 Digital low power TV and TV... interference from other low power TV, TV translator, Class A TV or TV booster stations or digital low power TV...

  7. Black Television: Avenue of Power

    ERIC Educational Resources Information Center

    Douglas, Pamela

    1973-01-01

    Analyzes a few of the prominent issues in black television, examining public television, commercial television, black ownership of stations, cable television, and some projections for the future. (Author/JM)

  8. Health information processing from television: the role of health orientation.

    PubMed

    Dutta, Mohan J

    2007-01-01

    The quintessential presence of television in modern American life has led to decades of research on the unhealthy effects of television. However, recent years have witnessed a surge in scholarship seeking to interrogate the positive health effects of television, particularly in the realm of incorporating health content into entertainment-based television programs. One of the important critical questions in the realm of the positive health effects of television focuses on the amount of health information learning contributed by health information content on television. This article takes a motivation-based approach to health information learning from television, arguing that health orientation influences the amount of health information learned by individuals from television. On the basis of 2 separate studies, the article demonstrates that individuals who learn health information from a variety of television programs are more health oriented than individuals who do not learn health information from these television programs.

  9. Mountain Plains Learning Experience Guide: Radio and T.V. Repair. Course: Television Repair.

    ERIC Educational Resources Information Center

    Arneson, R.; And Others

    One of four individualized courses included in a radio and television repair, curriculum, this course focuses on trouble-shooting procedures for both black and white and color television equipment. The course is comprised of ten units: (1) Introduction to/and Block Diagrams of Television, (2) Television Audio Section Troubles, (3) Television Video…

  10. 47 CFR 74.707 - Low power TV and TV translator station protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.707 Low power TV and TV translator... low power TV or TV translator stations, or TV booster stations within the following predicted contours... construct a new low power TV, TV translator, or TV booster station or change the facilities of an existing...

  11. 47 CFR 74.707 - Low power TV and TV translator station protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.707 Low power TV and TV translator... low power TV or TV translator stations, or TV booster stations within the following predicted contours... construct a new low power TV, TV translator, or TV booster station or change the facilities of an existing...

  12. 47 CFR 74.707 - Low power TV and TV translator station protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.707 Low power TV and TV translator... low power TV or TV translator stations, or TV booster stations within the following predicted contours... construct a new low power TV, TV translator, or TV booster station or change the facilities of an existing...

  13. 47 CFR 74.707 - Low power TV and TV translator station protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.707 Low power TV and TV translator... low power TV or TV translator stations, or TV booster stations within the following predicted contours... construct a new low power TV, TV translator, or TV booster station or change the facilities of an existing...

  14. 75 FR 70260 - Notice of Public Information Collection(s) Being Reviewed by the Federal Communications...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-17

    ... Construct or Make Changes in a Low Power TV, TV Translator, or TV Booster Station, FCC Form 346. Form Number... changes in a Low Power Television, TV Translator, or TV Booster broadcast station. On September 9, 2004..., Television Translator, and Television Booster Stations and to Amend Rules for Digital Class A Television...

  15. WE-AB-204-09: Respiratory Motion Correction in 4D-PET by Simultaneous Motion Estimation and Image Reconstruction (SMEIR)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalantari, F; Wang, J; Li, T

    2015-06-15

    Purpose: In conventional 4D-PET, images from different frames are reconstructed individually and aligned by registration methods. Two issues with these approaches are: 1) Reconstruction algorithms do not make full use of all projections statistics; and 2) Image registration between noisy images can Result in poor alignment. In this study we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) method for cone beam CT for motion estimation/correction in 4D-PET. Methods: Modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM- TV) is used to obtain a primary motion-compensated PET (pmc-PET) from all projection data using Demons derivedmore » deformation vector fields (DVFs) as initial. Motion model update is done to obtain an optimal set of DVFs between the pmc-PET and other phases by matching the forward projection of the deformed pmc-PET and measured projections of other phases. Using updated DVFs, OSEM- TV image reconstruction is repeated and new DVFs are estimated based on updated images. 4D XCAT phantom with typical FDG biodistribution and a 10mm diameter tumor was used to evaluate the performance of the SMEIR algorithm. Results: Image quality of 4D-PET is greatly improved by the SMEIR algorithm. When all projections are used to reconstruct a 3D-PET, motion blurring artifacts are present, leading to a more than 5 times overestimation of the tumor size and 54% tumor to lung contrast ratio underestimation. This error reduced to 37% and 20% for post reconstruction registration methods and SMEIR respectively. Conclusion: SMEIR method can be used for motion estimation/correction in 4D-PET. The statistics is greatly improved since all projection data are combined together to update the image. The performance of the SMEIR algorithm for 4D-PET is sensitive to smoothness control parameters in the DVF estimation step.« less

  16. Equivalence principle in chameleon models

    NASA Astrophysics Data System (ADS)

    Kraiselburd, Lucila; Landau, Susana J.; Salgado, Marcelo; Sudarsky, Daniel; Vucetich, Héctor

    2018-05-01

    Most theories that predict time and/or space variation of fundamental constants also predict violations of the weak equivalence principle (WEP). In 2004 Khoury and Weltman [1] proposed the so called chameleon field arguing that it could help avoiding experimental bounds on the WEP while having a nontrivial cosmological impact. In this paper we revisit the extent to which these expectations continue to hold as we enter the regime of high precision tests. The basis of the study is the development of a new method for computing the force between two massive bodies induced by the chameleon field which takes into account the influence on the field by both, the large and the test bodies. We confirm that in the thin shell regime the force does depend nontrivially on the test body's composition, even when the chameleon coupling constants βi=β are universal. We also propose a simple criterion based on energy minimization, that we use to determine which of the approximations used in computing the scalar field in a two body problem is better in each specific regime. As an application of our analysis we then compare the resulting differential acceleration of two test bodies with the corresponding bounds obtained from Eötvös type experiments. We consider two setups: (1) an Earth based experiment where the test bodies are made of Be and Al; (2) the Lunar Laser Ranging experiment. We find that for some choices of the free parameters of the chameleon model the predictions of the Eötvös parameter are larger than some of the previous estimates. As a consequence, we put new constrains on these free parameters. Our conclusions strongly suggest that the properties of immunity from experimental tests of the WEP, usually attributed to the chameleon and related models, should be carefully reconsidered. An important result of our analysis is that our approach leads to new constraints on the parameter space of the chameleon models.

  17. Shading correction assisted iterative cone-beam CT reconstruction

    NASA Astrophysics Data System (ADS)

    Yang, Chunlin; Wu, Pengwei; Gong, Shutao; Wang, Jing; Lyu, Qihui; Tang, Xiangyang; Niu, Tianye

    2017-11-01

    Recent advances in total variation (TV) technology enable accurate CT image reconstruction from highly under-sampled and noisy projection data. The standard iterative reconstruction algorithms, which work well in conventional CT imaging, fail to perform as expected in cone beam CT (CBCT) applications, wherein the non-ideal physics issues, including scatter and beam hardening, are more severe. These physics issues result in large areas of shading artifacts and cause deterioration to the piecewise constant property assumed in reconstructed images. To overcome this obstacle, we incorporate a shading correction scheme into low-dose CBCT reconstruction and propose a clinically acceptable and stable three-dimensional iterative reconstruction method that is referred to as the shading correction assisted iterative reconstruction. In the proposed method, we modify the TV regularization term by adding a shading compensation image to the reconstructed image to compensate for the shading artifacts while leaving the data fidelity term intact. This compensation image is generated empirically, using image segmentation and low-pass filtering, and updated in the iterative process whenever necessary. When the compensation image is determined, the objective function is minimized using the fast iterative shrinkage-thresholding algorithm accelerated on a graphic processing unit. The proposed method is evaluated using CBCT projection data of the Catphan© 600 phantom and two pelvis patients. Compared with the iterative reconstruction without shading correction, the proposed method reduces the overall CT number error from around 200 HU to be around 25 HU and increases the spatial uniformity by a factor of 20 percent, given the same number of sparsely sampled projections. A clinically acceptable and stable iterative reconstruction algorithm for CBCT is proposed in this paper. Differing from the existing algorithms, this algorithm incorporates a shading correction scheme into the low-dose CBCT reconstruction and achieves more stable optimization path and more clinically acceptable reconstructed image. The method proposed by us does not rely on prior information and thus is practically attractive to the applications of low-dose CBCT imaging in the clinic.

  18. Reading Meta-Television: A New Model for Reader-Response Criticism.

    ERIC Educational Resources Information Center

    Olson, Scott R.

    Many current models of television viewing regard viewers either as passive receptors, active participants, or addled dupes. A study proposed a more flexible model for television viewing research. The study used the television program "St. Elsewhere," an example of "meta-television" (television programming which contains hidden…

  19. 47 CFR 74.798 - Digital television transition notices by broadcasters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the highest number of viewers is watching. Stations have the discretion as to the form of these... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.798 Digital television transition notices by broadcasters. (a) Each low power television, TV translator and Class A television station...

  20. 47 CFR 74.798 - Digital television transition notices by broadcasters.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the highest number of viewers is watching. Stations have the discretion as to the form of these... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.798 Digital television transition notices by broadcasters. (a) Each low power television, TV translator and Class A television station...

  1. 47 CFR 74.798 - Digital television transition notices by broadcasters.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... the highest number of viewers is watching. Stations have the discretion as to the form of these... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.798 Digital television transition notices by broadcasters. (a) Each low power television, TV translator and Class A television station...

  2. 47 CFR 74.798 - Digital television transition notices by broadcasters.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the highest number of viewers is watching. Stations have the discretion as to the form of these... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.798 Digital television transition notices by broadcasters. (a) Each low power television, TV translator and Class A television station...

  3. Nielsen Television '73; A Look at the Medium.

    ERIC Educational Resources Information Center

    Nielsen (A.C.) Co., Chicago, IL.

    The latest (1973) edition of Nielsen Television presents data on the television audience. Major findings are graphically summarized and data are presented for: number of stations receivable by household; households equipped with TV sets; United States TV households with color television; total United States households using television by time of…

  4. Television for Deaf People: Selected Projects.

    ERIC Educational Resources Information Center

    Freebairn, Thomas

    Television projects for the deaf are described with special focus on activities by the Deafness Research and Training Center to develop a cable television cooperative to produce and distribute programs for the deaf. The chapter on cable television considers principles of cable television, the model for a cable television cooperative, steps in…

  5. 75 FR 81269 - Public Information Collection Requirement Submitted to OMB for Review and Approval, Comments...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-27

    ... Power Television Translator, Television Booster Stations, and to Amend Rules for Digital Class A... television translator (``TV translator'') stations and modifies certain rules applicable to digital Class A... (namely, ``low power television, TV translator, and Class A television station DTV licensees''). The...

  6. 76 FR 5158 - Notice of Public Information Collection(s) Being Submitted for Review and Approval to the Office...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-28

    ... Authority to Construct or Make Changes in a Low Power TV, TV Translator, or TV Booster Station, FCC Form 346... construct or make changes in a Low Power Television, TV Translator, or TV Booster broadcast station. On..., Television Translator, and Television Booster Stations and to Amend Rules for Digital Class A Television...

  7. Television, video, and computer game usage in children under 11 years of age.

    PubMed

    Christakis, Dimitri A; Ebel, Beth E; Rivara, Frederick P; Zimmerman, Frederick J

    2004-11-01

    To conduct a population-based survey of television and other media usage in young children to determine (1) total media usage; (2) the proportion of children who have televisions in their bedrooms and who eat breakfast or dinner in front of the television; and (3) predictors of parental concern about the amount of television their child watches. Telephone survey administered to 1454 parents of children <11 years old derived from a diverse clinic population. The mean age of the index child was 5.05 years. Mean daily reported child media use was as follows: television (1.45 hours; SD, 1.5); videos (1.1 hours; SD, 1.30); and computer games (0.54 hours; SD, 0.96). Thirty percent of parents reported that their child ate breakfast or dinner in front of the television in the past week, and 22% were concerned about the amount of television that their child watched. In multivariate linear regression, eating breakfast or dinner in front of the television in the past week was associated with increased hours of television viewing (0.38 hours [0.21, 0.54]) and video (0.19 hours [0.04, 0.34]). Having a television in a child's bedroom was associated with increased hours of television (0.25 hours [0.07, 0.43]), video viewing (0.31 hours [0.16, 0.47]), and computer games (0.21 hours [0.10, 0.32]). In general, higher parental education was associated with decreased hours of television and video but not computer games. Older children were 2 to 3 times more likely than younger children to have a television in their bedroom and to have eaten a meal in front of it in the past week. More educated parents were less likely to report that their child had a television in their bedroom and more likely to be concerned about the amount of television their child viewed. Combined video and computer game usage exceeded television usage. Both children of low- and high-income parents are at risk for certain behaviors associated with television usage. Parents whose children watched more television were more likely to be concerned about the amount of television their child viewed.

  8. CTV, ITV, ETV, PTV: Television and Education in the 1960s.

    ERIC Educational Resources Information Center

    Distance Education Report, 2000

    2000-01-01

    Discusses television in the 1960s as a form of communication including commercial television (CTV), public television (PTV), educational television (ETV), and instructional television (ITV). The Educational Media Study Panel (EMSP), an official advisory group to the Commissioner and the U.S. Office of Education, studied the growth of television…

  9. Inside Television: A Guide To Critical Viewing.

    ERIC Educational Resources Information Center

    White, Ned

    This course is divided into seven units, each focusing on a particular aspect of television. The unit topics and some of the subtopics included are: (1) television and the American viewer; (2) the television industry (the networks, the role of the Federal Communications Commission, public television, and the business of television); (3) programs…

  10. Television Games Preschool Children Play: Patterns, Themes and Uses.

    ERIC Educational Resources Information Center

    James, Navita Cummings; McCain, Thomas A.

    1982-01-01

    Analysis of relationship of television content to preschool children's play based on observations at day care center reveals that television is source of content in play; television-facilitated games are not "new"; developmental differences exist in use of television content in play; use of television content in play has positive consequences.…

  11. 76 FR 61358 - Information Collections Being Submitted for Review and Approval to the Office of Management and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-04

    ... Digital Low Power Television Translator, and Television Booster Stations and to Amend Rules for Digital...'') to transition from analog to digital broadcasting and states that low power television, TV translator...; Section 74.788; Low Power Television, TV Translator and Class A Television Digital Transition...

  12. 76 FR 23795 - Low-Power Television and Translator Upgrade Program: Notice of Final Closing Date

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-28

    .... 110418247-1247-01] Low-Power Television and Translator Upgrade Program: Notice of Final Closing Date AGENCY... receipt of applications for the Low-Power Television and Translator Upgrade Program (Upgrade Program) will... Rules to Establish Rules for Digital Low Power Television, Television Translator, and Television Booster...

  13. 76 FR 72704 - Information Collection Approved by the Office of Management and Budget (OMB)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-25

    ... 73.3598; CDBS Informal Forms; Section 74.788; Low Power Television, TV Translator and Class A... the Commission's Rules To Establish Rules for Digital Low Power Television Translator, and Television... and states that low *61359 power television, TV translator, and Class A television stations that have...

  14. Management practices for end-of-life cathode ray tube glass: Review of advances in recycling and best available technologies.

    PubMed

    Iniaghe, Paschal O; Adie, Gilbert U

    2015-11-01

    Cathode ray tubes are image display units found in computer monitors and televisions. In recent years, cathode ray tubes have been generated as waste owing to the introduction of newer and advanced technologies in image displays, such as liquid crystal displays and high definition televisions, among others. Generation and subsequent disposal of end-of-life cathode ray tubes presents a challenge owing to increasing volumes and high lead content embedded in the funnel and neck sections of the glass. Disposal in landfills and open dumping are anti-environmental practices considering the large-scale contamination of environmental media by the potential of toxic metals leaching from glass. Mitigating such environmental contamination will require sound management strategies that are environmentally friendly and economically feasible. This review covers existing and emerging management practices for end-of-life cathode ray tubes. An in-depth analysis of available technologies (glass smelting, detoxification of cathode ray tube glass, lead extraction from cathode ray tube glass) revealed that most of the techniques are environmentally friendly, but are largely confined to either laboratory scale, or are often limited owing to high cost to mount, or generate secondary pollutants, while a closed-looped method is antiquated. However, recycling in cementitious systems (cement mortar and concrete) gives an added advantage in terms of quantity of recyclable cathode ray tube glass at a given time, with minimal environmental and economic implications. With significant quantity of waste cathode ray tube glass being generated globally, cementitious systems could be economically and environmentally acceptable as a sound management practice for cathode ray tube glass, where other technologies may not be applicable. © The Author(s) 2015.

  15. 47 CFR 74.708 - Class A TV and digital Class A TV station protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.708 Class A TV and digital Class A TV... § 73.6010 of this chapter. (b) An application to construct a new low power TV, TV translator, or TV... prior to the date the low power TV, TV translator, or TV booster application is filed. (c) Applications...

  16. Multiscale properties of weighted total variation flow with applications to denoising and registration.

    PubMed

    Athavale, Prashant; Xu, Robert; Radau, Perry; Nachman, Adrian; Wright, Graham A

    2015-07-01

    Images consist of structures of varying scales: large scale structures such as flat regions, and small scale structures such as noise, textures, and rapidly oscillatory patterns. In the hierarchical (BV, L(2)) image decomposition, Tadmor, et al. (2004) start with extracting coarse scale structures from a given image, and successively extract finer structures from the residuals in each step of the iterative decomposition. We propose to begin instead by extracting the finest structures from the given image and then proceed to extract increasingly coarser structures. In most images, noise could be considered as a fine scale structure. Thus, starting the image decomposition with finer scales, rather than large scales, leads to fast denoising. We note that our approach turns out to be equivalent to the nonstationary regularization in Scherzer and Weickert (2000). The continuous limit of this procedure leads to a time-scaled version of total variation flow. Motivated by specific clinical applications, we introduce an image depending weight in the regularization functional, and study the corresponding weighted TV flow. We show that the edge-preserving property of the multiscale representation of an input image obtained with the weighted TV flow can be enhanced and localized by appropriate choice of the weight. We use this in developing an efficient and edge-preserving denoising algorithm with control on speed and localization properties. We examine analytical properties of the weighted TV flow that give precise information about the denoising speed and the rate of change of energy of the images. An additional contribution of the paper is to use the images obtained at different scales for robust multiscale registration. We show that the inherently multiscale nature of the weighted TV flow improved performance for registration of noisy cardiac MRI images, compared to other methods such as bilateral or Gaussian filtering. A clinical application of the multiscale registration algorithm is also demonstrated for aligning viability assessment magnetic resonance (MR) images from 8 patients with previous myocardial infarctions. Copyright © 2015. Published by Elsevier B.V.

  17. Micro-Computed Tomography Assessment of Fracture Healing: Relationships among Callus Structure, Composition, and Mechanical Function

    PubMed Central

    Morgan, Elise F.; Mason, Zachary D.; Chien, Karen B.; Pfeiffer, Anthony J.; Barnes, George L.; Einhorn, Thomas A.; Gerstenfeld, Louis C.

    2009-01-01

    Non-invasive characterization of fracture callus structure and composition may facilitate development of surrogate measures of the regain of mechanical function. As such, quantitative computed tomography- (CT-) based analyses of fracture calluses could enable more reliable clinical assessments of bone healing. Although previous studies have used CT to quantify and predict fracture healing, it is unclear which of the many CT-derived metrics of callus structure and composition are the most predictive of callus mechanical properties. The goal of this study was to identify the changes in fracture callus structure and composition that occur over time and that are most closely related to the regain of mechanical function. Micro-computed tomography (μCT) imaging and torsion testing were performed on murine fracture calluses (n=188) at multiple post-fracture timepoints and under different experimental conditions that alter fracture healing. Total callus volume (TV), mineralized callus volume (BV), callus mineralized volume fraction (BV/TV), bone mineral content (BMC), tissue mineral density (TMD), standard deviation of mineral density (σTMD), effective polar moment of inertia (Jeff), torsional strength, and torsional rigidity were quantified. Multivariate statistical analyses, including multivariate analysis of variance, principal components analysis, and stepwise regression were used to identify differences in callus structure and composition among experimental groups and to determine which of the μCT outcome measures were the strongest predictors of mechanical properties. Although calluses varied greatly in the absolute and relative amounts of mineralized tissue (BV, BMC, and BV/TV), differences among timepoints were most strongly associated with changes in tissue mineral density. Torsional strength and rigidity were dependent on mineral density as well as the amount of mineralized tissue: TMD, BV, and σTMD explained 62% of the variation in torsional strength (p<0.001); and TMD, BMC, BV/TV, and σTMD explained 70% of the variation in torsional rigidity (p<0.001). These results indicate that fracture callus mechanical properties can be predicted by several μCT-derived measures of callus structure and composition. These findings form the basis for developing non-invasive assessments of fracture healing and for identifying biological and biomechanical mechanisms that lead to impaired or enhanced healing. PMID:19013264

  18. TV Violence: What's All the Fuss About?

    ERIC Educational Resources Information Center

    Singer, Dorothy G.; Singer, Jerome L.

    1984-01-01

    Discusses problems posed by television violence; how behavioral and social scientists became interested in television violence and its effects on children; how psychologists study relationships between television violence and behavior; how television violence can be counteracted by television industry, parents, and educators; and results from the…

  19. Taking a Look at Television.

    ERIC Educational Resources Information Center

    King, William, Comp.

    1981-01-01

    A collection of quotations drawn from research and opinion papers dealing with the impact of television viewing on children. Subtopics addressed are: television viewing statistics, effects of television violence, and the relationship of television to education. (JJD)

  20. 47 CFR 74.710 - Digital low power TV and TV translator station protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital low power TV and TV translator station... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.710 Digital low power TV and TV translator station protection. (a) An application to construct a new low power TV, TV translator, or TV...

  1. Total-variation based velocity inversion with Bregmanized operator splitting algorithm

    NASA Astrophysics Data System (ADS)

    Zand, Toktam; Gholami, Ali

    2018-04-01

    Many problems in applied geophysics can be formulated as a linear inverse problem. The associated problems, however, are large-scale and ill-conditioned. Therefore, regularization techniques are needed to be employed for solving them and generating a stable and acceptable solution. We consider numerical methods for solving such problems in this paper. In order to tackle the ill-conditioning of the problem we use blockiness as a prior information of the subsurface parameters and formulate the problem as a constrained total variation (TV) regularization. The Bregmanized operator splitting (BOS) algorithm as a combination of the Bregman iteration and the proximal forward backward operator splitting method is developed to solve the arranged problem. Two main advantages of this new algorithm are that no matrix inversion is required and that a discrepancy stopping criterion is used to stop the iterations, which allow efficient solution of large-scale problems. The high performance of the proposed TV regularization method is demonstrated using two different experiments: 1) velocity inversion from (synthetic) seismic data which is based on Born approximation, 2) computing interval velocities from RMS velocities via Dix formula. Numerical examples are presented to verify the feasibility of the proposed method for high-resolution velocity inversion.

  2. Global temperature monitoring from space

    NASA Technical Reports Server (NTRS)

    Spencer, R. W.

    1994-01-01

    Global and regional temperature variations in the lower troposphere and lower stratosphere are examined for the period 1979-92 from Microwave Sounder Unit (MSU) data obtained by the Television Infrared Observation Satellite (TIROS)-N series of National Oceanic and Atmospheric Administration (NOAA) operational satellites. In the lower troposphere, globally-averaged temperature variations appear to be dominated by tropical El Nino (warm) and La Nina (cool) events and volcanic eruptions. The Pinatubo volcanic eruption in June 1991 appears to have initiated a cooling trend which persisted through the most recent data analyzed (July, 1992), and largely overwhelmed the warming from the 1991-92 El Nino. The cooling has been stronger in the Northern Hemisphere than in the Southern Hemisphere. The temperature trend over the 13.5 year satellite record is small (+0.03 C) compared to the year-to-year variability (0.2-0.4 C), making detection of any global warming signal fruitless to date. However, the future global warming trend, currently predicted to be around 0.3 C/decade, will be much easier to discern should it develop. The lower stratospheric temperature record is dominated by warm episodes from the Pinatubo eruption and the March 1982 eruption of El Chichon volcano.

  3. Effect of urban closed circuit television on assault injury and violence detection

    PubMed Central

    Sivarajasingam, V; Shepherd, J; Matthews, K

    2003-01-01

    Objective: To evaluate the effect of closed circuit television (CCTV) surveillance on levels of assault injury and violence detection. Design: Intervention versus control study design. Setting: Five town/cities with CCTV surveillance and five, matched control centres without CCTV surveillance in England. Intervention: CCTV installation and surveillance. Methods: Assault related emergency department attendances and violent offences recorded by the police in CCTV and control centres in the four years, 1995–99, two years before and two years after CCTV installation, were compared. Results: Assault related emergency department attendances decreased in intervention centres (3% decrease, ratio 0.96; 95% confidence interval (CI) 0.93 to 0.99) and increased in control centres (11% increase, ratio 1.11; 95% CI 1.08 to 1.14). Overall, changes in emergency department assault attendance in CCTV and control centres were significantly different (t test, p<0.05). Police recorded violence increased in CCTV (11% increase, ratio 1.16; 95% CI 1.08 to 1.24) and control centres (5% increase, ratio 1.06; 95% CI 0.99 to 1.13). Overall, changes in police recording in CCTV and control centres were not significantly different (t test, p>0.05). In CCTV centres, decreases in assault related emergency department attendances and increases in police violence detection were not uniform. Conclusion: CCTV surveillance was associated with increased police detection of violence and reductions in injury or severity of injury. CCTV centre variation deserves further study. PMID:14693891

  4. The educational experiments of school health promotion for the youth in Japan: analysis of the 'sport test' over the past 34 years.

    PubMed

    Shingo, Noi; Takeo, Masaki

    2002-06-01

    The objective of this study was to analyze independently the results of a 'sport test' that had been conducted in Japanese schools for 34 years without interruption, and to examine how physical education in Japanese schools affects health promotion in youths and what problems remain to be solved. The source of materials for the present study were the Annual Reports on the Survey of Physical Fitness and Athletic Ability for the period 1965-1998, published by the Ministry of Education, Science, Sports and Culture. Means and standard deviations of total scores from physical fitness and athletic ability tests in 11-year-olds (6th graders in elementary school), 14-year-olds (3rd graders in junior high school) and 17-year-olds (3rd graders in senior high school) were analyzed. The results of this study suggest that the trends of changes in mean score and coefficient of variation (CV) for physical fitness and athletic ability in Japanese youths are associated with the outcome of physical training through physical education in school, as well as the effect of the media--mainly television and television games. (1) The increase in mean scores and the decrease in CV observed from 1964 to the first half of the 1970s were probably due to the positive influence of the Guideline for Teaching. This guideline emphasized a systematic approach to athletic techniques, together with active practice of physical fitness training in schools, under the directives of the Boards of Education in response to the social 'Physical Fitness Campaign' policy at that time. (2) The leveling off of mean scores and CVs observed from the early half of the 1970s to the later half of the 1980s might be a result of the invasion of television into Japanese family life. (3) The decrease in mean scores and increase in CV observed since the later half of the 1980s were assumed to be caused by the negative influence of a Guideline for Teaching characterized by the key words 'Physical Education for More Pleasure' and a steep increase in the number of television games. (4) In terms of methodology, analyzing not only the mean scores but also the CV probably provided a more accurate evaluation of the outcome of health promotion in youths. In conclusion, strategies for health promotion in youths, especially for proper nurturing of physical fitness and athletic ability, should include not only delivery of physical fitness training in schools, but also continuous monitoring of multiple indicators, and ensuring proper 'Learning of the Body'. The latter should include providing learning opportunities centering on the 'body' (not the 'body' for the sake of labour or military manpower, but one's own 'body' per se); guiding young people to recognize the states of their own body and physical fitness, and to understand how they can be improved. To be effective in implementation, the need to increase the number of professional teachers in physical education should be examined. All possible opportunities should also be taken to inform youths of the negative effects of television and television games, and to encourage them to spend less time on these and more time being physically active from the moment they arise.

  5. A Fast and Accurate Algorithm for l1 Minimization Problems in Compressive Sampling (Preprint)

    DTIC Science & Technology

    2013-01-22

    However, updating uk+1 via the formulation of Step 2 in Algorithm 1 can be implemented through the use of the component-wise Gauss - Seidel iteration which...may accelerate the rate of convergence of the algorithm and therefore reduce the total CPU-time consumed. The efficiency of component-wise Gauss - Seidel ...Micchelli, L. Shen, and Y. Xu, A proximity algorithm accelerated by Gauss - Seidel iterations for L1/TV denoising models, Inverse Problems, 28 (2012), p

  6. Measuring the Effects of Cumulative Influence: Using NCW to Prevent or Minimize Civilian Casualties

    DTIC Science & Technology

    2007-06-01

    can be targeted.. How many computers, how many web site visits, how many TV channels, how many text capable cell phones , the number of email...Total number of cell phone text messages transmitted e. Total number of cell phone text messages replied to f. Build a location map of the city’s...determine how many of the identified people have email accounts, web pages, web logs or cell phone text capabilities. The campaign goes something like

  7. TV and Teens: Television In Adolescent Social Development.

    ERIC Educational Resources Information Center

    Luker, Richard; Johnston, Jerome

    1988-01-01

    Presents television as an instrument through which adolescents can gain social experience and strengthen social development. Examines the link between watching television and social relationships, discussing how television viewing can provide "blueprints" for behavior in social situations. Lists four steps for using television as a learning tool.…

  8. Television in the Schools: Instructional Television and Educational Media Resources at the National Public Broadcasting Archives

    ERIC Educational Resources Information Center

    King, Karen

    2008-01-01

    In 1964, in "A Guide to Instructional Television," editor Robert M. Diamond defined "educational television" as a "broad term usually applied to cultural and community broadcasting which may include some programs for in-school use" (p. 278). His definition for instructional television was "television used within the formal classroom context on any…

  9. The History of Television

    NASA Astrophysics Data System (ADS)

    Kuno, Hisao; Kamemoto, Kazuhiro

    The report provides a relevant explanation about the advance of the television technology, especially about the systems and the receivers, from the beginning of the television development. (1) From the beginning of TV development to World War II. (2) Resumption of TV development by the end of war. (3) Monochrome TV to color TV. (4) Television technology in New Media, Multimedia and IT era.

  10. On learning science and pseudoscience from prime-time television programming

    NASA Astrophysics Data System (ADS)

    Whittle, Christopher Henry

    The purpose of the present dissertation is to determine whether the viewing of two particular prime-time television programs, ER and The X-Files, increases viewer knowledge of science and to identify factors that may influence learning from entertainment television programming. Viewer knowledge of scientific dialogue from two science-based prime-time television programs, ER, a serial drama in a hospital emergency room and The X-Files, a drama about two Federal Bureau of Investigation agents who pursue alleged extraterrestrial life and paranormal activity, is studied. Level of viewing, education level, science education level, experiential factors, level of parasocial interaction, and demographic characteristics are assessed as independent variables affecting learning from entertainment television viewing. The present research involved a nine-month long content analysis of target television program dialogue and data collection from an Internet-based survey questionnaire posted to target program-specific on-line "chat" groups. The present study demonstrated that entertainment television program viewers incidentally learn science from entertainment television program dialogue. The more they watch, the more they learn. Viewing a pseudoscientific fictional television program does necessarily influence viewer beliefs in pseudoscience. Higher levels of formal science study are reflected in more science learning and less learning of pseudoscience from entertainment television program viewing. Pseudoscience learning from entertainment television programming is significantly related to experience with paranormal phenomena, higher levels of viewer parasocial interaction, and specifically, higher levels of cognitive parasocial interaction. In summary, the greater a viewer's understanding of science the more they learn when they watch their favorite science-based prime-time television programs. Viewers of pseudoscience-based prime-time television programming with higher levels of paranormal experiences and parasocial interaction demonstrate cognitive interest in and learning of their favorite television program characters ideas and beliefs. What television viewers learn from television is related to what they bring to the viewing experience. Television viewers are always learning, even when their intentions are to simply relax and watch the tube.

  11. The diffusion of television in India.

    PubMed

    Singhal, A; Doshi, J K; Rogers, E M; Rahman, S A

    1988-01-01

    Between 1980 and 1987, the number of television sets increased by 10 times in India. Television now reaches an audience of about 800 million, 10% of the population. 3 main reasons account for the rapid diffusion of television in India: the role of communication satellites in expanding access to television signals, the introduction and popularity of soap operas, and the increasing revenues to the national television system (Doordarshan) from commercial advertising. Hum Log, the 1st soap opera on the national network, was patterned after pro-development soap operas in Mexico and addresses social issues such as family communication, women's status, small family size, national integration, dowry, and alcoholism. The main lesson from the Hum Log experience was that indigenous soap operas can attract large audiences and substantial profits. A 1987 household survey indicated that television ownership is more common in urban areas (88% of households) than rural areas (52%) and among households with incomes above RS 1500 (75% of television owners). The commercialization of Indian television has precipitated a policy debate about television's role. Supporters of further expansion of television services cite popular will, the potential to use this medium for educational development, high advertising incomes, the ability of satellite television to penetrate rural areas, and high government expenditures for television broadcasting. On the other hand, detractors of the commercialization policy argue that television promotes consumerism, widens the gap between the urban elite and the rural poor, disregards regional sociocultural norms, and diverts funding from development programs in areas such as health and education.

  12. Rainfall measurement from the opportunistic use of an Earth-space link in the Ku band

    NASA Astrophysics Data System (ADS)

    Barthès, L.; Mallet, C.

    2013-08-01

    The present study deals with the development of a low-cost microwave device devoted to the measurement of average rain rates observed along Earth-satellite links, the latter being characterized by a tropospheric path length of a few kilometres. The ground-based power measurements, which are made using the Ku-band television transmissions from several different geostationary satellites, are based on the principle that the atmospheric attenuation produced by rain encountered along each transmission path can be used to determine the path-averaged rain rate. This kind of device could be very useful in hilly areas where radar data are not available or in urban areas where such devices could be directly placed in homes by using residential TV antenna. The major difficulty encountered with this technique is that of retrieving rainfall characteristics in the presence of many other causes of received signal fluctuation, produced by atmospheric scintillation, variations in atmospheric composition (water vapour concentration, cloud water content) or satellite transmission parameters (variations in emitted power, satellite pointing). In order to conduct a feasibility study with such a device, a measurement campaign was carried out over a period of five months close to Paris. The present paper proposes an algorithm based on an artificial neural network, used to identify dry and rainy periods and to model received signal variability resulting from effects not related to rain. When the altitude of the rain layer is taken into account, the rain attenuation can be inverted to obtain the path-averaged rain rate. The rainfall rates obtained from this process are compared with co-located rain gauges and radar measurements taken throughout the full duration of the campaign, and the most significant rainfall events are analysed.

  13. Patterns of time use among low-income urban minority adolescents and associations with academic outcomes and problem behaviors.

    PubMed

    Wolf, Sharon; Aber, J Lawrence; Morris, Pamela A

    2015-06-01

    Time budgets represent key opportunities for developmental support and contribute to an understanding of achievement gaps and adjustment across populations of youth. This study assessed the connection between out-of-school time use patterns and academic performance outcomes, academic motivations and goals, and problem behaviors for 504 low-income urban African American and Latino adolescents (54% female; M = 16.6 years). Time use patterns were measured across eight activity types using cluster analysis. Four groups of adolescents were identified, based on their different profiles of time use: (1) Academic: those with most time in academic activities; (2) Social: those with most time in social activities; (3) Maintenance/work: those with most time in maintenance and work activities; and (4) TV/computer: those with most time in TV or computer activities. Time use patterns were meaningfully associated with variation in outcomes in this population. Adolescents in the Academic cluster had the highest levels of adjustment across all domains; adolescents in the Social cluster had the lowest academic performance and highest problem behaviors; and adolescents in the TV/computer cluster had the lowest levels of intrinsic motivation. Females were more likely to be in the Academic cluster, and less likely to be in the other three clusters compared to males. No differences by race or gender were found in assessing the relationship between time use and outcomes. The study's results indicate that time use patterns are meaningfully associated with within-group variation in adjustment for low-income minority adolescents, and that shared contexts may shape time use more than individual differences in race/ethnicity for this population.

  14. Nonsmooth, nonconvex regularizers applied to linear electromagnetic inverse problems

    NASA Astrophysics Data System (ADS)

    Hidalgo-Silva, H.; Gomez-Trevino, E.

    2017-12-01

    Tikhonov's regularization method is the standard technique applied to obtain models of the subsurface conductivity distribution from electric or electromagnetic measurements by solving UT (m) = | F (m) - d |2 + λ P(m). The second term correspond to the stabilizing functional, with P (m) = | ∇ m |2 the usual approach, and λ the regularization parameter. Due to the roughness penalizer inclusion, the model developed by Tikhonov's algorithm tends to smear discontinuities, a feature that may be undesirable. An important requirement for the regularizer is to allow the recovery of edges, and smooth the homogeneous parts. As is well known, Total Variation (TV) is now the standard approach to meet this requirement. Recently, Wang et.al. proved convergence for alternating direction method of multipliers in nonconvex, nonsmooth optimization. In this work we present a study of several algorithms for model recovering of Geosounding data based on Infimal Convolution, and also on hybrid, TV and second order TV and nonsmooth, nonconvex regularizers, observing their performance on synthetic and real data. The algorithms are based on Bregman iteration and Split Bregman method, and the geosounding method is the low-induction numbers magnetic dipoles. Non-smooth regularizers are considered using the Legendre-Fenchel transform.

  15. Measuring sense of presence and user characteristics to predict effective training in an online simulated virtual environment.

    PubMed

    De Leo, Gianluca; Diggs, Leigh A; Radici, Elena; Mastaglio, Thomas W

    2014-02-01

    Virtual-reality solutions have successfully been used to train distributed teams. This study aimed to investigate the correlation between user characteristics and sense of presence in an online virtual-reality environment where distributed teams are trained. A greater sense of presence has the potential to make training in the virtual environment more effective, leading to the formation of teams that perform better in a real environment. Being able to identify, before starting online training, those user characteristics that are predictors of a greater sense of presence can lead to the selection of trainees who would benefit most from the online simulated training. This is an observational study with a retrospective postsurvey of participants' user characteristics and degree of sense of presence. Twenty-nine members from 3 Air Force National Guard Medical Service expeditionary medical support teams participated in an online virtual environment training exercise and completed the Independent Television Commission-Sense of Presence Inventory survey, which measures sense of presence and user characteristics. Nonparametric statistics were applied to determine the statistical significance of user characteristics to sense of presence. Comparing user characteristics to the 4 scales of the Independent Television Commission-Sense of Presence Inventory using Kendall τ test gave the following results: the user characteristics "how often you play video games" (τ(26)=-0.458, P<0.01) and "television/film production knowledge" (τ(27)=-0.516, P<0.01) were significantly related to negative effects. Negative effects refer to adverse physiologic reactions owing to the virtual environment experience such as dizziness, nausea, headache, and eyestrain. The user characteristic "knowledge of virtual reality" was significantly related to engagement (τ(26)=0.463, P<0.01) and negative effects (τ(26)=-0.404, P<0.05). Individuals who have knowledge about virtual environments and experience with gaming environments report a higher sense of presence that indicates that they will likely benefit more from online virtual training. Future research studies could include a larger population of expeditionary medical support, and the results obtained could be used to create a model that predicts the level of presence based on the user characteristics. To maximize results and minimize costs, only those individuals who, based on their characteristics, are supposed to have a higher sense of presence and less negative effects could be selected for online simulated virtual environment training.

  16. 47 CFR 73.6019 - Digital Class A TV station protection of low power TV, TV translator, digital low power TV and...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Digital Class A TV station protection of low power TV, TV translator, digital low power TV and digital TV translator stations. 73.6019 Section 73... BROADCAST SERVICES Class A Television Broadcast Stations § 73.6019 Digital Class A TV station protection of...

  17. From Regional to National Clouds: TV Coverage in the Czech Republic

    PubMed Central

    Sucháček, Jan; Sed’a, Petr; Friedrich, Václav; Wachowiak-Smolíková, Renata; Wachowiak, Mark P.

    2016-01-01

    Media, and particularly TV media, have a great impact on the general public. In recent years, spatial patterns of information and the relevance of intangible geographies have become increasingly important. Gatekeeping plays a critical role in the selection of information that is transformed into media. Therefore, gatekeeping, through national media, also co-forms the generation of mental maps. In this paper, correspondence analysis (a statistical method) combined with cloud lines (a new visual analytics technique) is used to analyze how individual major regional events in one of the post-communist countries, the Czech Republic, penetrate into the media on a national scale. Although national news should minimize distortions about regions, this assumption has not been verified by our research. Impressions presented by the media of selected regions that were markedly influenced by one or several events in those regions demonstrate that gatekeepers, especially news reporters, functioned as a filter by selecting only a few specific, and in many cases, unusual events for dissemination. PMID:27824947

  18. Adaptive sigmoid function bihistogram equalization for image contrast enhancement

    NASA Astrophysics Data System (ADS)

    Arriaga-Garcia, Edgar F.; Sanchez-Yanez, Raul E.; Ruiz-Pinales, Jose; Garcia-Hernandez, Ma. de Guadalupe

    2015-09-01

    Contrast enhancement plays a key role in a wide range of applications including consumer electronic applications, such as video surveillance, digital cameras, and televisions. The main goal of contrast enhancement is to increase the quality of images. However, most state-of-the-art methods induce different types of distortion such as intensity shift, wash-out, noise, intensity burn-out, and intensity saturation. In addition, in consumer electronics, simple and fast methods are required in order to be implemented in real time. A bihistogram equalization method based on adaptive sigmoid functions is proposed. It consists of splitting the image histogram into two parts that are equalized independently by using adaptive sigmoid functions. In order to preserve the mean brightness of the input image, the parameter of the sigmoid functions is chosen to minimize the absolute mean brightness metric. Experiments on the Berkeley database have shown that the proposed method improves the quality of images and preserves their mean brightness. An application to improve the colorfulness of images is also presented.

  19. Electronic photography: a new age of medical imaging?

    PubMed

    Tübergen, D; Manegold, B C

    1993-07-01

    This is a critical overview of present conceptions of the introduction of electronic photography in medicine. It is not a complete list of products, rather it is a description of how the requirements of the physician have influenced medical illustration in the past and will continue to do so in the future. Video systems are widely used in medicine. Besides the learning and teaching of effects of television, minimal invasive surgery (MIS) has become reality through endoscopy, rapidly accepted worldwide. Documentation of endoscopic procedures and their effects is becoming routine. Therefore, the conversion of complex optical information into binary units is a logical development to save space for storage. The reproduction, storage and transfer of detailed images is already realized by digital camera systems, photo CD, scanners and picture archiving and communicating system (PACS). Now electronic imaging in medicine has to be regarded as a matter of routine. The real impact of accelerated editing will be shown in the future.

  20. 47 CFR 76.51 - Major television markets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Major television markets. 76.51 Section 76.51 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.51 Major television markets. For...

  1. 47 CFR 76.51 - Major television markets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Major television markets. 76.51 Section 76.51 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.51 Major television markets. For...

  2. 47 CFR 76.51 - Major television markets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Major television markets. 76.51 Section 76.51 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.51 Major television markets. For...

  3. 47 CFR 76.51 - Major television markets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Major television markets. 76.51 Section 76.51 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.51 Major television markets. For...

  4. Teaching Television Watchers.

    ERIC Educational Resources Information Center

    Dunn, Judy Lee

    1994-01-01

    Presents activities to help teachers address the needs and behaviors of students raised on television; includes resources to help teachers use television productively in the classroom, a send-home reproducible on children and television violence, and notes on an interview with Shari Lewis and television tips for primary students. (SM)

  5. TV Tips for Parents: Using Television To Help Your Child Learn.

    ERIC Educational Resources Information Center

    Corporation for Public Broadcasting, Washington, DC.

    Recognizing that children watch an average of 25 hours of television per week, this booklet is designed to help parents redirect their children's television viewing to higher quality programs. Ten "tips" are provided to help parents guide their children's television (TV) viewing: (1) set your child's TV schedule; (2) get involved (in the child's…

  6. 47 CFR 74.707 - Low power TV and TV translator station protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Low power TV and TV translator station... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.707 Low power TV and TV translator station protection. (a)(1) A low power TV or TV translator will be protected from interference from other...

  7. Children's Learning from Broadcast Television: The Relationship between the Amount of Time a Child Watches Television with and without Adults and That Child's Learning from Television.

    ERIC Educational Resources Information Center

    Storm, Susan Ruotsala

    A study examined young children's learning from selected television program content in varied subject matter and the relationship between that learning and the amount of time a child watches television with and without adults. A 28-item learning test based on instructional design principles was developed from selected television segments and…

  8. Use of television, videogames, and computer among children and adolescents in Italy.

    PubMed

    Patriarca, Alessandro; Di Giuseppe, Gabriella; Albano, Luciana; Marinelli, Paolo; Angelillo, Italo F

    2009-05-13

    This survey determined the practices about television (video inclusive), videogames, and computer use in children and adolescents in Italy. A self-administered anonymous questionnaire covered socio-demographics; behaviour about television, videogames, computer, and sports; parental control over television, videogames, and computer. Overall, 54.1% and 61% always ate lunch or dinner in front of the television, 89.5% had a television in the bedroom while 52.5% of them always watched television there, and 49% indicated that parents controlled the content of what was watched on television. The overall mean length of time daily spent on television viewing (2.8 hours) and the frequency of watching for at least two hours per day (74.9%) were significantly associated with older age, always ate lunch or dinner while watching television, spent more time playing videogames and using computer. Those with parents from a lower socio-economic level were also more likely to spend more minutes viewing television. Two-thirds played videogames for 1.6 daily hours and more time was spent by those younger, males, with parents that do not control them, who watched more television, and who spent more time at the computer. The computer was used by 85% of the sample for 1.6 daily hours and those older, with a computer in the bedroom, with a higher number of computers in home, who view more television and play videogames were more likely to use the computer. Immediate and comprehensive actions are needed in order to diminish time spent at the television, videogames, and computer.

  9. Use of television, videogames, and computer among children and adolescents in Italy

    PubMed Central

    Patriarca, Alessandro; Di Giuseppe, Gabriella; Albano, Luciana; Marinelli, Paolo; Angelillo, Italo F

    2009-01-01

    Background This survey determined the practices about television (video inclusive), videogames, and computer use in children and adolescents in Italy. Methods A self-administered anonymous questionnaire covered socio-demographics; behaviour about television, videogames, computer, and sports; parental control over television, videogames, and computer. Results Overall, 54.1% and 61% always ate lunch or dinner in front of the television, 89.5% had a television in the bedroom while 52.5% of them always watched television there, and 49% indicated that parents controlled the content of what was watched on television. The overall mean length of time daily spent on television viewing (2.8 hours) and the frequency of watching for at least two hours per day (74.9%) were significantly associated with older age, always ate lunch or dinner while watching television, spent more time playing videogames and using computer. Those with parents from a lower socio-economic level were also more likely to spend more minutes viewing television. Two-thirds played videogames for 1.6 daily hours and more time was spent by those younger, males, with parents that do not control them, who watched more television, and who spent more time at the computer. The computer was used by 85% of the sample for 1.6 daily hours and those older, with a computer in the bedroom, with a higher number of computers in home, who view more television and play videogames were more likely to use the computer. Conclusion Immediate and comprehensive actions are needed in order to diminish time spent at the television, videogames, and computer. PMID:19439070

  10. Television Studies: A Widening Perspective.

    ERIC Educational Resources Information Center

    Comstock, George

    1981-01-01

    Reviews three books concerned with the effects of television advertising upon children and their parents: "Television Advertising and Children," edited by June Esserman; "Children and the Faces of Television," edited by Edward Palmer and Aimee Dorr; and "The Effects of Television Advertising on Children," by Richard Adler and others. (JJD)

  11. 47 CFR 76.611 - Cable television basic signal leakage performance criteria.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable television basic signal leakage... television basic signal leakage performance criteria. (a) No cable television system shall commence or... one of the following cable television basic signal leakage performance criteria: (1) prior to carriage...

  12. 47 CFR 73.674 - Digital television transition notices by broadcasters.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Digital television transition notices by... RADIO SERVICES RADIO BROADCAST SERVICES Television Broadcast Stations § 73.674 Digital television... broadcasting to digital television (DTV). For each such commercial station, a licensee or permittee must elect...

  13. The Television Generation, Television Literacy, and Television Trends.

    ERIC Educational Resources Information Center

    Cohen, Jodi R.

    Unlike the linear, serial process of reading books, learning to "read" television is a parallel process in which multiple pieces of information are simultaneously received. Perceiving images, only one aspect of understanding television, requires the concurrent processing of information that is compounded within a symbol system. The…

  14. Cable Television; A Bibliographic Review.

    ERIC Educational Resources Information Center

    Schoenung, James

    This bibliographic review of publications in the field of cable television begins with an introduction to cable television and an outline of the history and development of cable television. Particular attention is given to the regulatory activities of the Federal Communications Commission and the unfulfilled potential of cable television. The…

  15. Television Violence: Content, Context, and Consequences. ERIC Digest.

    ERIC Educational Resources Information Center

    Aidman, Amy

    This digest reports recent findings on violent television content, highlights the recently developed television ratings system, and offers suggestions for parental mediation of children's television viewing. The National Television Violence Study has demonstrated that not all violence is equal. Certain plot elements in portrayals of violence are…

  16. Children and Television.

    ERIC Educational Resources Information Center

    Chevallier, Eric; Mansour, Sylvie

    1993-01-01

    This booklet examines the influence of television on children and adolescents in developing and developed nations, reviewing research on television's relationship to child health and development. The first section reviews specific research on such variables as number of television sets in use, amount of time spent watching television, age, sex,…

  17. ALLFlight: detection of moving objects in IR and ladar images

    NASA Astrophysics Data System (ADS)

    Doehler, H.-U.; Peinecke, Niklas; Lueken, Thomas; Schmerwitz, Sven

    2013-05-01

    Supporting a helicopter pilot during landing and takeoff in degraded visual environment (DVE) is one of the challenges within DLR's project ALLFlight (Assisted Low Level Flight and Landing on Unprepared Landing Sites). Different types of sensors (TV, Infrared, mmW radar and laser radar) are mounted onto DLR's research helicopter FHS (flying helicopter simulator) for gathering different sensor data of the surrounding world. A high performance computer cluster architecture acquires and fuses all the information to get one single comprehensive description of the outside situation. While both TV and IR cameras deliver images with frame rates of 25 Hz or 30 Hz, Ladar and mmW radar provide georeferenced sensor data with only 2 Hz or even less. Therefore, it takes several seconds to detect or even track potential moving obstacle candidates in mmW or Ladar sequences. Especially if the helicopter is flying with higher speed, it is very important to minimize the detection time of obstacles in order to initiate a re-planning of the helicopter's mission timely. Applying feature extraction algorithms on IR images in combination with data fusion algorithms of extracted features and Ladar data can decrease the detection time appreciably. Based on real data from flight tests, the paper describes applied feature extraction methods for moving object detection, as well as data fusion techniques for combining features from TV/IR and Ladar data.

  18. International Cooperation for a Single World Production Standard of High Definition Television.

    ERIC Educational Resources Information Center

    Hongcharu, Boonchai

    Broadcasters, television engineers and the production industry have encountered many problems with diverse television standards since the introduction of color television. With the advent of high definition television (HDTV), the chance to have a common production standard for international exchange of programs and technical information has…

  19. 1977 Television; a Catalog of Instructional Courses and Related Material.

    ERIC Educational Resources Information Center

    Agency for Instructional Television, Bloomington, IN.

    A catalog of instructional television courses was compiled by the Agency for Instructional Television, a nonprofit American-Canadian organization established to develop cooperative program projects and to distribute television and related print materials for use as major learning resources. Over l00 television courses are included for primary…

  20. National Television Violence Study. Volume 1.

    ERIC Educational Resources Information Center

    Seawell, Margaret, Ed.

    The National Television Violence Study (NTVS) was a 3-year effort to assess the effects of violence on television, of particular interest to education professionals is the effects of television violence on children. Funded by the National Cable Television Association, the project began in June 1994 and involved the participation of media scholars…

  1. National Television Violence Study. Volume 3.

    ERIC Educational Resources Information Center

    Seawell, Margaret, Ed.

    The National Television Violence Study (NTVS) was a 3-year effort to assess the effects of violence on television, of particular interest to education professionals is the effects of television violence on children. Funded by the National Cable Television Association, the project began in June 1994 and involved the participation of media scholars…

  2. National Television Violence Study. Volume 2.

    ERIC Educational Resources Information Center

    Seawell, Margaret, Ed.

    The National Television Violence Study (NTVS) was a 3-year effort to assess the effects of violence on television, of particular interest to education professionals is the effects of television violence on children. Funded by the National Cable Television Association, the project began in June 1994 and involved the participation of media scholars…

  3. A Structuralist Approach to Television Criticism.

    ERIC Educational Resources Information Center

    Robards, Brooks

    Although television is highly dependent on language and semiotic analysis, its form can best be analyzed through the structural notion of transformation. The critic's task becomes the articulation of structural laws intrinsic to television. One such law has to do with how television structures time. Television programming transforms action into…

  4. The "Checkers" Speech and Televised Political Communication.

    ERIC Educational Resources Information Center

    Flaningam, Carl

    Richard Nixon's 1952 "Checkers" speech was an innovative use of television for political communication. Like television news itself, the campaign fund crisis behind the speech can be thought of in the same terms as other television melodrama, with the speech serving as its climactic episode. The speech adapted well to television because…

  5. Television's Role in the Socialization of African American Children and Adolescents.

    ERIC Educational Resources Information Center

    Stroman, Carolyn A.

    1991-01-01

    Examines television's role in the social development of Black children, including television's use, socialization content, potential antisocial and prosocial effects, and television as an educator. concludes that television is a significant player in the socialization (cognitive and social learning) of Black children with positive and negative…

  6. FEDERAL PROGRAMS FOR EDUCATIONAL TELEVISION.

    ERIC Educational Resources Information Center

    BYSTROM, JOHN W.

    THE GROWTH AND PROGRESS OF EDUCATIONAL TELEVISION IS DESCRIBED. GRANTS FOR THE CONSTRUCTION OF NONCOMMERCIAL TELEVISION (TV) BROADCASTING STATIONS (EDUCATIONAL TV FACILITIES ACT), GRANTS OF SURPLUS PROPERTY UNDER THE NATIONAL DEFENSE EDUCATION ACT HAVE AIDED THE GROWTH OF EDUCATIONAL TV. GREATER USE IS MADE OF EDUCATIONAL TV BECAUSE OF GREATER USE…

  7. Presidential Elections in the Age of Television.

    ERIC Educational Resources Information Center

    Rothwell, Jennifer Truran

    2000-01-01

    Explores the role of television in politics providing historical examples of the use of television and its possible effects on elections. Focuses on television as the dominant medium for politics, the connections among television, advertising, and political money, and ideas for reforming the electoral process. Includes a teaching activity on…

  8. Television's Impact on Fantasy Play: A Review of Research.

    ERIC Educational Resources Information Center

    van der Voort, Tom H.; Valkenburg, Patti M.

    1994-01-01

    Reviews research literature on television's influence on children's fantasy play. Notes evidence that television viewing absorbs time that children would otherwise spend in play and that television's influence on play depends on the types of programs watched. Examines whether television viewing influences fantasy play positively or negatively and…

  9. Some Structural Characteristics of Music Television Videos.

    ERIC Educational Resources Information Center

    Fry, Donald L.; Fry, Virginia H.

    1987-01-01

    Indicates, by analyzing two types of montage structures, that music television is a hybrid form of television programing displaying visual characteristics of both television commercials and drama. Argues that this amalgam of different characteristics gives music television its distinctive look and power as a promotional tool for the record…

  10. 47 CFR 74.792 - Digital low power TV and TV translator station protected contour.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital low power TV and TV translator station... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.792 Digital low power TV and TV translator station protected contour. (a) A digital low power TV or TV translator will be protected from...

  11. High-definition television evaluation for remote handling task performance

    NASA Astrophysics Data System (ADS)

    Fujita, Y.; Omori, E.; Hayashi, S.; Draper, J. V.; Herndon, J. N.

    Described are experiments designed to evaluate the impact of HDTV (High-Definition Television) on the performance of typical remote tasks. The experiments described in this paper compared the performance of four operators using HDTV with their performance while using other television systems. The experiments included four television systems: (1) high-definition color television, (2) high-definition monochromatic television, (3) standard-resolution monochromatic television, and (4) standard-resolution stereoscopic monochromatic television. The stereo system accomplished stereoscopy by displaying two cross-polarized images, one reflected by a half-silvered mirror and one seen through the mirror. Observers wore spectacles with cross-polarized lenses so that the left eye received only the view from the left camera and the right eye received only the view from the right camera.

  12. Reality television predicts both positive and negative outcomes for adolescent girls.

    PubMed

    Ferguson, Christopher J; Salmond, Kimberlee; Modi, Kamla

    2013-06-01

    To assess the influence of media, specifically reality television, on adolescent behavior. A total of 1141 preteen and adolescent girls (age range 11-17) answered questions related to their reality television viewing, personality, self-esteem, relational aggression, appearance focus, and desire for fame. Our results indicated that the influence of reality television on adolescent behavior is complex and potentially related to the adolescents' intended uses and gratifications for using reality television. Reality television viewing was positively related to increased self-esteem and expectations of respect in dating relationships. However, watching reality television also was related to an increased focus on appearance and willingness to compromise other values for fame. Reality television viewing did not predict relational aggression. The potential influences of reality television use on adolescent girls are both positive and negative, defying easy categorization. Copyright © 2013 Mosby, Inc. All rights reserved.

  13. Food commercials increase preference for energy-dense foods, particularly in children who watch more television.

    PubMed

    Boyland, Emma J; Harrold, Joanne A; Kirkham, Tim C; Corker, Catherine; Cuddy, Jenna; Evans, Deborah; Dovey, Terence M; Lawton, Clare L; Blundell, John E; Halford, Jason C G

    2011-07-01

    Our aim was to determine if levels of television viewing (a proxy measure for habitual commercial exposure) affect children's food preference responses to television food commercials. A total of 281 children aged 6 to 13 years from northwest England viewed toy or food television commercials followed by a cartoon on 2 separate occasions; they then completed 3 food preference measures, a commercial recognition task, and a television viewing questionnaire. After viewing the food commercials, all children selected more branded and nonbranded fat-rich and carbohydrate-rich items from food preference checklists compared with after viewing the toy commercials. The food preferences of children with higher habitual levels of television viewing were more affected by food commercial exposure than those of low television viewers. After viewing food commercials, high television viewing children selected a greater number of branded food items compared with after the toy commercials as well as compared with the low television viewers. Children correctly recognized more food commercials than toy commercials. Exposure to television food commercials enhanced high television viewers' preferences for branded foods and increased reported preferences for all food items (branded and nonbranded) relative to the low television viewers. This is the first study to demonstrate that children with greater previous exposure to commercials (high television viewers) seemed to be more responsive to food promotion messages than children with lower previous advertising exposure. Copyright © 2011 by the American Academy of Pediatrics.

  14. Conductivity map from scanning tunneling potentiometry.

    PubMed

    Zhang, Hao; Li, Xianqi; Chen, Yunmei; Durand, Corentin; Li, An-Ping; Zhang, X-G

    2016-08-01

    We present a novel method for extracting two-dimensional (2D) conductivity profiles from large electrochemical potential datasets acquired by scanning tunneling potentiometry of a 2D conductor. The method consists of a data preprocessing procedure to reduce/eliminate noise and a numerical conductivity reconstruction. The preprocessing procedure employs an inverse consistent image registration method to align the forward and backward scans of the same line for each image line followed by a total variation (TV) based image restoration method to obtain a (nearly) noise-free potential from the aligned scans. The preprocessed potential is then used for numerical conductivity reconstruction, based on a TV model solved by accelerated alternating direction method of multiplier. The method is demonstrated on a measurement of the grain boundary of a monolayer graphene, yielding a nearly 10:1 ratio for the grain boundary resistivity over bulk resistivity.

  15. LDA-Based Unified Topic Modeling for Similar TV User Grouping and TV Program Recommendation.

    PubMed

    Pyo, Shinjee; Kim, Eunhui; Kim, Munchurl

    2015-08-01

    Social TV is a social media service via TV and social networks through which TV users exchange their experiences about TV programs that they are viewing. For social TV service, two technical aspects are envisioned: grouping of similar TV users to create social TV communities and recommending TV programs based on group and personal interests for personalizing TV. In this paper, we propose a unified topic model based on grouping of similar TV users and recommending TV programs as a social TV service. The proposed unified topic model employs two latent Dirichlet allocation (LDA) models. One is a topic model of TV users, and the other is a topic model of the description words for viewed TV programs. The two LDA models are then integrated via a topic proportion parameter for TV programs, which enforces the grouping of similar TV users and associated description words for watched TV programs at the same time in a unified topic modeling framework. The unified model identifies the semantic relation between TV user groups and TV program description word groups so that more meaningful TV program recommendations can be made. The unified topic model also overcomes an item ramp-up problem such that new TV programs can be reliably recommended to TV users. Furthermore, from the topic model of TV users, TV users with similar tastes can be grouped as topics, which can then be recommended as social TV communities. To verify our proposed method of unified topic-modeling-based TV user grouping and TV program recommendation for social TV services, in our experiments, we used real TV viewing history data and electronic program guide data from a seven-month period collected by a TV poll agency. The experimental results show that the proposed unified topic model yields an average 81.4% precision for 50 topics in TV program recommendation and its performance is an average of 6.5% higher than that of the topic model of TV users only. For TV user prediction with new TV programs, the average prediction precision was 79.6%. Also, we showed the superiority of our proposed model in terms of both topic modeling performance and recommendation performance compared to two related topic models such as polylingual topic model and bilingual topic model.

  16. 47 CFR 73.5000 - Services subject to competitive bidding.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... following broadcast services are subject to competitive bidding: AM; FM; FM translator; analog television; low-power television; television translator; and Class A television. Mutually exclusive applications...

  17. NAEB TECHNICAL REPORT ON THE IMPACT OF AIRBORNE TELEVISION TRANSMISSION ON LAND-BASED UHF TELEVISION ASSIGNMENT PLANS.

    ERIC Educational Resources Information Center

    BRONSON, VERNON; AND OTHERS

    OPERATIONAL EFFECTS OF AIRBORNE EDUCATIONAL TELEVISION ON ULTRAHIGH FREQUENCY (UHF) TELEVISION ASSIGNMENTS ON LAND WERE INVESTIGATED. SPECIFICALLY, THE EFFORT RELATED TO EXPANSION PLANS OF THE MIDWEST PROGRAM ON AIRBORNE TELEVISION INSTRUCTION (MPATI). PREVIOUS STUDIES BY THE NATIONAL ASSOCIATION OF EDUCATIONAL BROADCASTERS (NAEB) LED TO THE…

  18. Using Television to Stimulate Learning and Develop Evaluative Reasoning.

    ERIC Educational Resources Information Center

    Williams, David M.; Wright, Ian

    1980-01-01

    Poses two questions regarding use of television in the social studies classroom--"How can television be used as motivation for learning?" and "How can teachers assist students to make rational evaluations concerning the issues presented on television?" Answers to these questions focus on teaching methods involving television in the classroom.…

  19. Regulations; Office of Cable Television, State of New Jersey.

    ERIC Educational Resources Information Center

    New Jersey State Dept. of Public Utilities, Trenton. Office of Cable Television.

    Regulations promulgated in accordance with the authority provided the Office of Cable Television, Board of Public Utility Commissioners, State of New Jersey, to regulate cable television in the public interest are set forth. These apply to cable television (CATV) companies which own, control, operate, or manage cable television systems and to…

  20. The Work of the Television Journalist.

    ERIC Educational Resources Information Center

    Tyrrell, Robert

    This book describes the various functions of the television journalist--in the United States and Great Britain--and supplies knowledge enabling members of a television team to work successfully as a unit. Separate chapters are devoted to discussions of (1) the world of television journalism, (2) writing for television, (3) the role of the…

  1. The Effects of Television on Children. Foundation for Child and Youth Studies Selected Papers Number 47.

    ERIC Educational Resources Information Center

    Tregoning, Julia

    This paper begins with an introduction which covers viewing time; television as a significant developmental experience; Piagetian stages of cognitive development; and changing developmental tastes in television viewing. The paper then focuses on television in relation to learning; television and violence; advertising; and parents' ability to…

  2. Television and the American Family. Second Edition.

    ERIC Educational Resources Information Center

    Bryant, Jennings, Ed.; Bryant, J. Alison, Ed.

    Noting drastic changes in both television and the family since the 1990 edition, this revised volume provides an extensive consideration of television's role in the American family, from the uses families make of television and how extensions such as remote controls and VCRs affect usage, to the meanings families have for television, families'…

  3. Effects of Television on Children: What is the Evidence?

    ERIC Educational Resources Information Center

    Comstock, George

    Studies and writings on the effects of television on children are reviewed and summarized. Topics are the young people's pattern of exposure to television, the nature of their viewing experience, the way they respond to television, and the direct effects on their values, attitudes and behavior. Research on the influence of television violence on…

  4. Television's Child; The Impact of Television on Today's Children; What Parents Can Do About It.

    ERIC Educational Resources Information Center

    Morris, Norman S.

    Based on an extensive series of interviews with clinical psychiatrists and psychologists, educators, television executives, producers, performers, advertisers, parents, and children themselves, this book explores the effect of television on a child's values. It delves into the question of a relationship between violence on television and violent…

  5. Television Violence and Behavior: The Effects of Television Violence on Children.

    ERIC Educational Resources Information Center

    Crump, Charla A.

    Television violence and the impact it has on children is a growing concern in the world today. Although research indicates that violence on television triggers aggressive behavior in children, the characteristics of those children also need to be examined. Factors such as age, intellectual level, identification with television personalities, the…

  6. Children and Television. Current Issues in Education: A Bibliographic Series. Volume 5, No. 1, July 1988.

    ERIC Educational Resources Information Center

    Christo, Doris Hedlund

    Focused on research concerning children and television, this annotated bibliography lists 44 articles selected from the Educational Resources Information Center (ERIC) database from 1983 to 1988. Topics include: (1) the effects of television violence on children; (2) television viewing patterns; (3) children's television programs; and (4)…

  7. 47 CFR 76.70 - Exemption from input selector switch rules.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... broadcast television station, or non-commercial educational television translator station operating with 5... service broadcast television station, or new non-commercial educational television translator station with...

  8. Testing of a Spray-Bar Zero Gravity Cryogenic Vent System for Upper Stages

    NASA Technical Reports Server (NTRS)

    Lak, Tibor; Flachbart, Robin; Nguyen, Han; Martin, James

    1999-01-01

    The capability to vent in zero gravity without resettling is a fundamental technology need that involves practically all uses of subcritical cryogenics in space. Venting without resettling would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule- Thomson (J-T) valve to extract then-nal energy from the propellant. In a cooperative effort, Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (N4HTB) was used to test a unique "spray bar" TVS system developed by Boeing. A schematic of this system is included in Figure 1. The system consists of a recirculation pump, a parallel flow concentric tube, heat exchanger, and a spray bar positioned close to the longitudinal axis of the tank. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it radially into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the spray bar heat exchanger element, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. Figure 2 is a plot of ullage pressure (P4) and liquid vapor pressure (PSAI) versus time. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point, the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating boil-off losses. The primary advantage of the spray bar configuration is that pressure reduction is achieved independent of liquid and vapor location, thereby enhancing the applicability of normal gravity test data to zero gravity conditions. The in-tank components are minimized with the proposed TVS design. Because the recirculation pump is external to the tank, no electrical power penetration of the tank is required for pump or valve operation. This is especially desirable for L02 tanks since the presence of an electrical ignition source in oxygen represents a critical failure mode. Also, since the critical components (pump, motor, valve, orifice) are external to the tank, system checkout and ground servicing/replacement are easier. For zero-g operation, component replacement external to the tank may be a significant benefit. In addition to satisfying the zero g TVS design objectives, the TVS concept tested offers additional benefits to the integrated subcritical cryogenic storage and launch system.

  9. Television and children's executive function.

    PubMed

    Lillard, Angeline S; Li, Hui; Boguszewski, Katie

    2015-01-01

    Children spend a lot of time watching television on its many platforms: directly, online, and via videos and DVDs. Many researchers are concerned that some types of television content appear to negatively influence children's executive function. Because (1) executive function predicts key developmental outcomes, (2) executive function appears to be influenced by some television content, and (3) American children watch large quantities of television (including the content of concern), the issues discussed here comprise a crucial public health issue. Further research is needed to reveal exactly what television content is implicated, what underlies television's effect on executive function, how long the effect lasts, and who is affected. © 2015 Elsevier Inc. All rights reserved.

  10. Comparative responses to radio and television anti-smoking advertisements to encourage smoking cessation.

    PubMed

    Durkin, Sarah; Wakefield, Melanie

    2010-03-01

    While mass media campaigns have been shown to contribute to reductions in smoking prevalence, little research has been undertaken on the effectiveness of radio advertising as a communication medium. This is despite radio being less expensive and having greater reach than television in some low and middle income countries. We aimed to explore the potential of radio as an adjunct or alternative to televised campaigns by comparing reactions to a radio anti-smoking ad with three televised anti-smoking ads, all of which communicated the serious health consequences of smoking in an emotionally evocative way. In pre-exposure interviews, 18-59-year-old daily smokers (n = 306) were asked to listen to a particular radio time slot/watch a particular television program that they usually listened to/watched, in which the ad was broadcast. Post-exposure interviews were conducted within 3 days of exposure and measured recall, recognition, emotional and cognitive responses, and intentions to quit smoking. Findings indicate that the radio ad showed similar or slightly higher levels than a concurrently aired television ad on understanding (radio: 96%; television: 95%), believability (radio: 89%; television: 90%), concern about smoking (both 77%) and motivation to quit (radio: 51%; television: 45%), and significantly higher levels of unprompted recall (radio: 20%; television: 6%). It also compared well against two subsequent anti-smoking television ads. Emotionally evocative radio advertising may be an effective adjunct or alternative to television advertising in jurisdictions where there are substantial limits on funds available for airing these campaigns, or where the reach of radio outstrips television.

  11. [Some aspects of the influence of television on children in early adolescence].

    PubMed

    Warmuz, Aneta; Stemplewska, Bozena; Witanowska, Jolanta; Sikora, Alicja

    2004-01-01

    Television is treated not only as a carrier of information, but first of all as a source of entertainment. From the other sites, it also carries many threats to young spectator. It is known already today, that many remittances are full of aggression. In what way does this special group of audience uses the TV remittances? This problem is analyzed in presented study. Diagnosis of problem was conducted among children attending to secondary schools. An investigative tool was a questionnaire of inquiry which included following questions: quantity of time spent in front of television set, influence of television on functioning of a child, rules of using the television at home, what kinds of televisions' offers children use, influence of television on social functioning of child (contacts with peers, with family) and influence of television on intellectual functioning of a child.

  12. 47 CFR 73.3572 - Processing of TV broadcast, Class A TV broadcast, low power TV, TV translators, and TV booster...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Processing of TV broadcast, Class A TV... Rules Applicable to All Broadcast Stations § 73.3572 Processing of TV broadcast, Class A TV broadcast... considered minor only if the change(s) will not increase the signal range of the Class A TV, low power TV or...

  13. 47 CFR 73.3572 - Processing of TV broadcast, Class A TV broadcast, low power TV, TV translators, and TV booster...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Processing of TV broadcast, Class A TV... Rules Applicable to All Broadcast Stations § 73.3572 Processing of TV broadcast, Class A TV broadcast... considered minor only if the change(s) will not increase the signal range of the Class A TV, low power TV or...

  14. 47 CFR 73.3572 - Processing of TV broadcast, Class A TV broadcast, low power TV, TV translators, and TV booster...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Processing of TV broadcast, Class A TV... Rules Applicable to All Broadcast Stations § 73.3572 Processing of TV broadcast, Class A TV broadcast... considered minor only if the change(s) will not increase the signal range of the Class A TV, low power TV or...

  15. 47 CFR 73.3572 - Processing of TV broadcast, Class A TV broadcast, low power TV, TV translators, and TV booster...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Processing of TV broadcast, Class A TV... Rules Applicable to All Broadcast Stations § 73.3572 Processing of TV broadcast, Class A TV broadcast... considered minor only if the change(s) will not increase the signal range of the Class A TV, low power TV or...

  16. Do parental co-viewing and discussions mitigate TV-induced fears in young children?

    PubMed

    Paavonen, E J; Roine, M; Pennonen, M; Lahikainen, A R

    2009-11-01

    While excessive television viewing has been associated with negative outcomes in children's welfare, parental co-viewing has been suggested as an effective way to prevent these negative effects. The objective of the present study is to specify some social contexts of co-viewing and to assess whether co-viewing modifies the effects of media on children's TV-related fears. The study is based on a representative random sample of 331 children aged 5-6 years. It is based on parental reports of children's TV-related fears and family television viewing practices. Parental co-viewing and discussion of television programmes with the child were found to be associated with higher rates of children's TV-related fears, high television exposure in general and watching adults' television programmes. The association between TV-related fears and co-viewing remained significant even after controlling for gender, maternal education, family income and the quantity and quality of television viewing. Co-viewing and TV-related discussions increased the risk for TV-related fears nearly fourfold (adjusted odds ratio 3.92, 95% confidence interval 1.37-11.17 and adjusted odds ratio 3.31, 95% confidence interval 1.33-8.20, respectively). The findings suggest that co-viewing and discussing television programmes are more common in families where television exposure is high. Because both co-viewing and discussing television programmes were associated with higher fear scores regardless of the quantity and quality of television exposure, the research shows that in everyday life co-viewing may not be done in such a way that it leads to a reduction of children's fears. More studies are needed to explore the co-viewing practices of families in more detail.

  17. Amount of Hispanic youth exposure to food and beverage advertising on Spanish- and English-language television.

    PubMed

    Fleming-Milici, Frances; Harris, Jennifer L; Sarda, Vishnudas; Schwartz, Marlene B

    2013-08-01

    Exposure to large numbers of television advertisements for foods and beverages with little or no nutritional value likely contributes to poor diet among youth. Given higher rates of obesity and overweight for Hispanic youth, it is important to understand the amount and types of food advertising they view. To quantify the amount of food and beverage advertising viewed by Hispanic youth on Spanish- and English-language television and compare it with the amount of food and beverage advertising viewed by non-Hispanic youth. Data on gross rating points that measured advertising viewed on national broadcast and cable television in 2010 using a Nielsen panel of television-viewing households of Hispanic and non-Hispanic preschoolers (2-5 years), children (6-11 years), and adolescents (12-17 years). Food and beverage television advertisements viewed on English- and Spanish-language television by product category and television-viewing times by age and language preference. EXPOSURE Food and beverage advertising on Spanish- and English-language television. RESULTS In 2010, Hispanic preschoolers, children, and adolescents viewed, on average, 11.6 to 12.4 television food ads per day; the majority of these ads (75%-85%) appeared on English-language television. Fast food represented a higher proportion of food ads on Spanish-language television. Consistent with television-viewing patterns, Hispanic preschoolers saw more Spanish-language food advertisements than did Hispanic children and adolescents. Owing to somewhat less food advertising on Spanish-language television, Hispanic children and adolescents viewed 14% and 24% fewer food ads overall, respectively, compared with non-Hispanic youth. Spanish-language television viewing was highly concentrated among youth who primarily speak Spanish. Both Hispanic and non-Hispanic youth view large numbers of television advertisements for nutrient-poor categories of food and beverage. Although Hispanic children and adolescents see somewhat fewer of these ads, the higher obesity rates among Hispanic youth, the greater exposure by Hispanic preschoolers, and the potential enhanced effects of targeted advertising on Hispanic youth suggest that this exposure may pose additional risks for Hispanic youth. Continued monitoring is warranted owing to food companies' stated intentions to increase marketing to Hispanics.

  18. Selecting Television Programs for Language Learning: Investigating Television Programs from the Same Genre

    ERIC Educational Resources Information Center

    Webb, Stuart

    2011-01-01

    The scripts of 288 television episodes were analysed to determine the extent to which vocabulary reoccurs in television programs from the same subgenres and unrelated television programs from different genres. Episodes from two programs from each of the following three subgenres of the American drama genre: medical, spy/action, and criminal…

  19. One Week of Educational Television. Number Six. March 9-15, 1970.

    ERIC Educational Resources Information Center

    Rockman, Saul; Hudson, Robert B.

    In this sixth survey of educational television in the United States, 187 UHF-VHF educational television (ETV) stations, 27 ITFS (Instructional Television Fixed Service) systems, and 35 CCTV (closed circuit television) systems reported on their operating policies and on their programming during the week of March 9-15, 1970. The amount and kind of…

  20. Television Viewing Habits of Kindergarten, Third and Sixth Grade Students in a Western Kentucky County.

    ERIC Educational Resources Information Center

    Bossing, Lewis; Mikulcik, Marilyn

    Parents from rural and urban areas of Calloway County, Kentucky were surveyed regarding their children's television viewing habits. Fifteen survey questions were asked, among them whether there was a television set in the home; whether the child had a personal set; whether the family ate meals while watching television; whether television sound…

  1. 47 CFR 73.9001 - Redistribution control of digital television broadcasts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Redistribution control of digital television... RADIO SERVICES RADIO BROADCAST SERVICES Digital Broadcast Television Redistribution Control § 73.9001 Redistribution control of digital television broadcasts. Licensees of TV broadcast stations may utilize the...

  2. 47 CFR 74.635 - Unattended operation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Stations § 74.635 Unattended operation. (a) TV relay stations, TV translator relay stations, TV STL... persons; (3) TV relay stations, TV STL stations, TV translator relay stations, and TV microwave booster... control point. Additionally, a TV translator relay station (and any associated TV microwave booster...

  3. The Relations between Television Exposure and Executive Function in Chinese Preschoolers: The Moderated Role of Parental Mediation Behaviors

    PubMed Central

    Yang, Xiaohui; Chen, Zhe; Wang, Zhenhong; Zhu, Liqi

    2017-01-01

    The present study examined the relations between preschoolers’ television exposure and executive functions (EF). One hundred and nineteen 3- to 6-year-old children and their parents participated. Parents filled in a questionnaire regarding children’s television viewing time, television content and parental mediation behaviors about their child’s television viewing. The children were asked to finish six EF tasks, including the backward digit span task, the spatial span task, the boy–girl Stroop, the Simon task, the flanker task and the Tower of Hanoi task that assessed working memory, inhibition and planning, respectively. Children’s vocabulary was tested using Peabody Picture Vocabulary Test, and included as control variables in addition to socioeconomic status of the participated families. The results showed that television viewing time and child-directed educational programs were positively associated with EF. In addition, television content fully mediated the effect of television viewing time on EF and parental restrictive approach strategies moderated the effect of television viewing time on EF. PMID:29089912

  4. Hidden addiction: Television

    PubMed Central

    Sussman, Steve; Moran, Meghan B.

    2013-01-01

    Background and aims: The most popular recreational pastime in the U.S. is television viewing. Some researchers have claimed that television may be addictive. We provide a review of the definition, etiology, prevention and treatment of the apparent phenomenon of television addiction. Methods: Selective review. Results: We provide a description of television (TV) addiction, including its negative consequences, assessment and potential etiology, considering neurobiological, cognitive and social/cultural factors. Next, we provide information on its prevention and treatment. Discussion and conclusions: We suggest that television addiction may function similarly to substance abuse disorders but a great deal more research is needed. PMID:25083294

  5. Impact of the media on adolescent sexual attitudes and behaviors.

    PubMed

    Escobar-Chaves, S Liliana; Tortolero, Susan R; Markham, Christine M; Low, Barbara J; Eitel, Patricia; Thickstun, Patricia

    2005-07-01

    Adolescents in the United States are engaging in sexual activity at early ages and with multiple partners. The mass media have been shown to affect a broad range of adolescent health-related attitudes and behaviors including violence, eating disorders, and tobacco and alcohol use. One largely unexplored factor that may contribute to adolescents' sexual activity is their exposure to mass media. We sought to determine of what is and is not known on a scientific basis of the effects of mass media on adolescent sexual attitudes and behaviors. Method. We performed an extensive, systematic review of the relevant biomedical and social science literature and other sources on the sexual content of various mass media, the exposure of adolescents to that media, the effects of that exposure on the adolescents' sexual attitudes and behaviors, and ways to mitigate those effects. Inclusion criteria were: published in 1983-2004, inclusive; published in English; peer-reviewed (for effects) or otherwise authoritative (for content and exposure); and a study population of American adolescents 11 to 19 years old or comparable groups in other postindustrial English-speaking countries. Excluded from the study were populations drawn from college students. Although television is subject to ongoing tracking of its sexual content, other media are terra incognita. Data regarding adolescent exposure to various media are, for the most part, severely dated. Few studies have examined the effects of mass media on adolescent sexual attitudes and behaviors: only 12 of 2522 research-related documents (<1%) involving media and youth addressed effects, 10 of which were peer reviewed. None can serve as the grounding for evidence-based public policy. These studies are limited in their generalizability by their cross-sectional study designs, limited sampling designs, and small sample sizes. In addition, we do not know the long-term effectiveness of various social-cultural, technologic, and media approaches to minimizing that exposure (eg, V-Chips on television, Internet-filtering-software, parental supervision, rating systems) or minimizing the effects of that exposure (eg, media-literacy programs). Research needs to include development of well-specified and robust research measures and methodologies; ongoing national surveillance of the sexual content of media and the exposure of various demographic subgroups of adolescents to that content; and longitudinal studies of the effects of that exposure on the sexual decision-making, attitudes, and behaviors of those subgroups. Additional specific research foci involve the success of various types of controls in limiting exposure and the mitigative effects of, for example, parental influence and best-practice media-literacy programs.

  6. Reality Television Programs Are Associated With Illegal Drug Use and Prescription Drug Misuse Among College Students.

    PubMed

    Fogel, Joshua; Shlivko, Alexander

    2016-01-02

    Reality television watching and social media use are popular activities. Reality television can include mention of illegal drug use and prescription drug misuse. To determine if reality television and social media use of Twitter are associated with either illegal drug use or prescription drug misuse. Survey of 576 college students in 2011. Independent variables included watching reality television (social cognitive theory), parasocial interaction (parasocial interaction theory), television hours watched (cultivation theory), following a reality television character on Twitter, and demographics. Outcome variables were illegal drug use and prescription drug misuse. Watching reality television and also identifying with reality TV program characters were each associated with greater odds for illegal drug use. Also, following a reality TV character on Twitter had greater odds for illegal drug use and also in one analytical model for prescription drug misuse. No support was seen for cultivation theory. Those born in the United States had greater odds for illegal drug use and prescription drug misuse. Women and Asians had lower odds for illegal drug use. African Americans and Asians had lower odds for prescription drug misuse. Physicians, psychologists, and other healthcare practitioners may find it useful to include questions in their clinical interview about reality television watching and Twitter use. Physician and psychology groups, public health practitioners, and government health agencies should consider discussing with television broadcasting companies the potential negative impact of including content with illegal drugs and prescription drug misuse on reality television programs.

  7. Children's understanding of television advertising: a revisit in the Chinese context.

    PubMed

    Chan, Kara; McNeal, James U

    2004-03-01

    The authors conducted a survey of 1,758 elementary school children (6-14 years old) from December 2001, to March 2002, in 3 Chinese cities with different levels of television advertising. The authors used D. R. John's (1999) model of consumer socialization as the theoretical framework for their study. More than half of the children whom the authors interviewed were able to understand that television stations broadcast commercials to earn money. Their understanding of the purposes of television commercials and the persuasive intention of television commercials developed with age. The authors examined the influence of gender, level of advertising, and level of television viewing on children's understanding of television advertising by using 3-way factorial models.

  8. 47 CFR 74.710 - Digital low power TV and TV translator station protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.710 Digital low power TV and TV... booster station or change the facilities of an existing station will not be accepted if it fails to... filed prior to the date the low power TV, TV translator, or TV booster application is filed. (b...

  9. 47 CFR 74.710 - Digital low power TV and TV translator station protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.710 Digital low power TV and TV... booster station or change the facilities of an existing station will not be accepted if it fails to... filed prior to the date the low power TV, TV translator, or TV booster application is filed. (b...

  10. 47 CFR 74.710 - Digital low power TV and TV translator station protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.710 Digital low power TV and TV... booster station or change the facilities of an existing station will not be accepted if it fails to... filed prior to the date the low power TV, TV translator, or TV booster application is filed. (b...

  11. 47 CFR 74.708 - Class A TV and digital Class A TV station protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.708 Class A TV and digital Class A TV... booster station or change the facilities of an existing station will not be accepted if it fails to... prior to the date the low power TV, TV translator, or TV booster application is filed. (c) Applications...

  12. 47 CFR 74.708 - Class A TV and digital Class A TV station protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.708 Class A TV and digital Class A TV... booster station or change the facilities of an existing station will not be accepted if it fails to... prior to the date the low power TV, TV translator, or TV booster application is filed. (c) Applications...

  13. 47 CFR 74.710 - Digital low power TV and TV translator station protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.710 Digital low power TV and TV... booster station or change the facilities of an existing station will not be accepted if it fails to... filed prior to the date the low power TV, TV translator, or TV booster application is filed. (b...

  14. 47 CFR 74.708 - Class A TV and digital Class A TV station protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.708 Class A TV and digital Class A TV... booster station or change the facilities of an existing station will not be accepted if it fails to... prior to the date the low power TV, TV translator, or TV booster application is filed. (c) Applications...

  15. 47 CFR 74.708 - Class A TV and digital Class A TV station protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.708 Class A TV and digital Class A TV... booster station or change the facilities of an existing station will not be accepted if it fails to... prior to the date the low power TV, TV translator, or TV booster application is filed. (c) Applications...

  16. Symposium on Television Violence (Colloque sur la Violence a la Television); Queen's University, Kingston, Ontario, Canada, August 24-26, 1975.

    ERIC Educational Resources Information Center

    Canadian Radio-Television Commission, Ottawa (Ontario).

    This book presents material from a symposium on television violence that was organized by the Canadian Radio-Television Commission. Part 1, "The Public Issue," discusses the social effects of mass media and violence as a dramatic convention. Part 2, "The Social Effects of Television Violence," provides experiments, research,…

  17. Selling Color: The Development and Marketing of the NTSC Color Television Broadcasting Technology and the Implications for HDTV.

    ERIC Educational Resources Information Center

    Gutenko, Gregory

    The introduction and acceptance of color television and the National Television System Committee (NTSC) color standard are reviewed for the lessons they hold for the future of high definition television (HDTV). Between 1946 and 1974, 28 years of salesmanship were required to move color television from the experimental phase to its assimilation…

  18. Children's Television Violence; Statement Before the Senate Subcommittee on Communications of the Senate Commerce Committee.

    ERIC Educational Resources Information Center

    Johnson, Nicholas

    The staff of the Surgeon General's report on Television and Social Behavior has given us five volumes of reports documenting television's adverse impact on our children's mental health. Action for Children's Television has pointed out what television executives are doing to make our children into little consumers. These are but small instances in…

  19. On the Cable; The Television of Abundance. Report of the Sloan Commission on Cable Communications.

    ERIC Educational Resources Information Center

    Alfred P. Sloan Foundation, New York, NY.

    The Sloan Commission report on cable television surveys the history and technology of cable television and suggests the prospects and possibilities the medium offers to the American public. The possible impact of cable television on over-the-air television is projected, and the possible shape of entertainment, news and opinion, public services,…

  20. Multi-stream face recognition for crime-fighting

    NASA Astrophysics Data System (ADS)

    Jassim, Sabah A.; Sellahewa, Harin

    2007-04-01

    Automatic face recognition (AFR) is a challenging task that is increasingly becoming the preferred biometric trait for identification and has the potential of becoming an essential tool in the fight against crime and terrorism. Closed-circuit television (CCTV) cameras have increasingly been used over the last few years for surveillance in public places such as airports, train stations and shopping centers. They are used to detect and prevent crime, shoplifting, public disorder and terrorism. The work of law-enforcing and intelligence agencies is becoming more reliant on the use of databases of biometric data for large section of the population. Face is one of the most natural biometric traits that can be used for identification and surveillance. However, variations in lighting conditions, facial expressions, face size and pose are a great obstacle to AFR. This paper is concerned with using waveletbased face recognition schemes in the presence of variations of expressions and illumination. In particular, we will investigate the use of a combination of wavelet frequency channels for a multi-stream face recognition using various wavelet subbands as different face signal streams. The proposed schemes extend our recently developed face veri.cation scheme for implementation on mobile devices. We shall present experimental results on the performance of our proposed schemes for a number of face databases including a new AV database recorded on a PDA. By analyzing the various experimental data, we shall demonstrate that the multi-stream approach is robust against variations in illumination and facial expressions than the previous single-stream approach.

Top