Structural and seismic analyses of waste facility reinforced concrete storage vaults
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, C.Y.
1995-07-01
Facility 317 of Argonne National Laboratory consists of several reinforced concrete waste storage vaults designed and constructed in the late 1940`s through the early 1960`s. In this paper, structural analyses of these concrete vaults subjected to various natural hazards are described, emphasizing the northwest shallow vault. The natural phenomenon hazards considered include both earthquakes and tornados. Because these vaults are deeply embedded in the soil, the SASSI (System Analysis of Soil-Structure Interaction) code was utilized for the seismic calculations. The ultimate strength method was used to analyze the reinforced concrete structures. In all studies, moment and shear strengths at criticalmore » locations of the storage vaults were evaluated. Results of the structural analyses show that almost all the waste storage vaults meet the code requirements according to ACI 349--85. These vaults also satisfy the performance goal such that confinement of hazardous materials is maintained and functioning of the facility is not interrupted.« less
14. END VIEW OF THE PLUTONIUM STORAGE VAULT FROM THE ...
14. END VIEW OF THE PLUTONIUM STORAGE VAULT FROM THE REMOTE CONTROL STATION. THE STACKER-RETRIEVER, A REMOTELY-OPERATED, MECHANIZED TRANSPORT SYSTEM, RETRIEVES CONTAINERS OF PLUTONIUM FROM SAFE GEOMETRY PALLETS STORED ALONG THE LENGTH OF THE VAULT. THE STACKER-RETRIEVER RUNS ALONG THE AISLE BETWEEN THE PALLETS OF THE STORAGE CHAMBER. (3/2/86) - Rocky Flats Plant, Plutonium Recovery Facility, Northwest portion of Rocky Flats Plant, Golden, Jefferson County, CO
Storage Area (1942 section), looking east, showing all of Vault ...
Storage Area (1942 section), looking east, showing all of Vault No. 1 door behind wall opening and sprinkler system - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC
NASA Technical Reports Server (NTRS)
Hoover, R. B.; Rhodes, C. M. (Inventor)
1981-01-01
Dye fading during archival storage of developed color photographic film is retarded by placing the film in a sealed, opaque vault, introducing a dry, pressurized inert gas into the vault while the latter is vented, and sealing the vault after the air within the vault has been purged and replaced by the inert gas. Preferably, the gas is nitrogen; and the vault is stored at a temperature below room temperature to preserve the color photographic emulsions on the film contained within the vault. For short-term storage, sodium thiocyanate pads charged with water are placed within the vault. For long term storage, the interior of the vault is kept at a low relative humidity.
Detail of bricked up storage vault opening Central of ...
Detail of bricked up storage vault opening - Central of Georgia Railway, Savannah Repair Shops & Terminal Facilities, Brick Storage Vaults under Jones Street, Bounded by West Broad, Jones, West Boundary & Hull Streets, Savannah, Chatham County, GA
3. View, piping and stack associated with the oxidizer vault ...
3. View, piping and stack associated with the oxidizer vault storage area in foreground with Systems Integration Laboratory (T-28) in background, looking northwest. - Air Force Plant PJKS, Systems Integration Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO
Cleanup Verification Package for the 118-F-7, 100-F Miscellaneous Hardware Storage Vault
DOE Office of Scientific and Technical Information (OSTI.GOV)
M. J. Appel
2006-11-02
This cleanup verification package documents completion of remedial action for the 118-F-7, 100-F Miscellaneous Hardware Storage Vault. The site consisted of an inactive solid waste storage vault used for temporary storage of slightly contaminated reactor parts that could be recovered and reused for the 100-F Area reactor operations.
20. Interior view of fuel storage pit or vault adjacent ...
20. Interior view of fuel storage pit or vault adjacent to Test Cell 9 in Component Test Laboratory (T-27), looking west. Photograph shows upgraded instrumentation, piping, tanks, and technological modifications installed in 1997-99 to accommodate component testing requirements for the Atlas V missile. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willoner, T.; Turlington, R.; Koenig, R.
The U.S. Department of Energy (DOE) (Environmental Management [EM], Office of Packaging and Transportation [EM-45]) Packaging and Certification Program (DOE PCP) has developed a Radio Frequency Identification (RFID) tracking and monitoring system, called ARG-US, for the management of nuclear materials packages during transportation and storage. The performance of the ARG-US RFID equipment and system has been fully tested in two demonstration projects in April 2008 and August 2009. With the strong support of DOE-SR and DOE PCP, a field testing program was completed in Savannah River Site's K-Area Material Storage (KAMS) Facility, an active Category I Plutonium Storage Facility, inmore » 2010. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault for operational testing. This latest version (Mark III) of the Argonne RFID system now has the capability to measure radiation dose and dose rate. This paper will report field testing progress of the ARG-US RFID equipment in KAMS, the operability and reliability trend results associated with the applications of the system, and discuss the potential benefits in enhancing safety, security and materials accountability. The purpose of this Phase II K Area test is to verify the accuracy of the radiation monitoring and proper functionality of the ARG-US RFID equipment and system under a realistic environment in the KAMS facility. Deploying the ARG-US RFID system leads to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including environmental condition monitoring and radiation monitoring. The successful completion of the testing program will provide field data to support a future development and testing. This will increase Operation efficiency and cost effectiveness for vault operation. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault. Deploying the ARG-US RFID system lends to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including radiation and environmental monitoring. The successful completion of the testing program will provide field data to support future development and testing.« less
Vu-Van, Tu; Pham-Duc, Phuc; Winkler, Mirko S; Zurbrügg, Christian; Zinsstag, Jakob; Le Thi Thanh, Huong; Bich, Tran Huu; Nguyen-Viet, Hung
2017-02-01
We studied the influence of different additive materials (lime, and rice husk) and aeration conditions on Ascaris lumbricoides egg die-off in 24 vaults of an experimental excreta storage unit. Excreta samples were collected once every two weeks over a 181-day period. Temperature, pH, and moisture content were recorded. A. lumbricoides eggs were quantitatively analyzed by the Romanenko method, which identified and counted live and dead eggs. From the first sampling (0 storage day) to the final sampling (181 storage days) the average percentage of viable A. lumbricoides eggs decreased gradually from 76.72 ± 11.23% (mean ± SD) to 8.26 ± 5.20%. The storage time and the high pH value significantly increased the die-off of helminth eggs. Over 181 storage days, all vaults option effectively reduced A. lumbricoides eggs die-off. The best vault option, with aeration and 10% lime per total weight, met the WHO standard for excreta treatment on the 111th storage day.
Radiological air quality in a depleted uranium storage vault
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, T.; Cucchiara, A.L.
1999-03-01
The radiological air quality of two storage vaults, one with depleted uranium (DU) and one without, was evaluated and compared. The intent of the study was to determine if the presence of stored DU would significantly contribute to the gaseous/airborne radiation level compared to natural background. Both vaults are constructed out of concrete and are dimensionally similar. The vaults are located on the first floor of the same building. Neither vault has air supply or air exhaust. The doors to both vaults remained closed during the evaluation period, except for brief and infrequent access by the operational group. One vaultmore » contained 700 KG of depleted uranium, and the other vault contained documents inside of file cabinets. Radon detectors and giraffe air samplers were used to gather data on the quantity of gaseous/airborne radionuclides in both vaults. The results of this study indicated that there was no significant difference in the quantity of gaseous/airborne radionuclides in the two vaults. This paper gives a discussion of the effects of the stored DU on the air quality, and poses several theories supporting the results.« less
1. VIEW OF ONE OF THE INNER ROOMS WITHIN VAULT ...
1. VIEW OF ONE OF THE INNER ROOMS WITHIN VAULT 996. THE UNDERGROUND VAULTS WERE USED TO STORE SPECIAL NUCLEAR MATERIAL AWAITING ON- AND OFF-SITE SHIPMENT. - Rocky Flats Plant, Storage Vault, Southeast corner of protected area, Northwest of Building 991, Golden, Jefferson County, CO
MTR BASEMENT. DOORWAY TO SOURCE STORAGE VAULT IS AT CENTER ...
MTR BASEMENT. DOORWAY TO SOURCE STORAGE VAULT IS AT CENTER OF VIEW; TO DECONTAMINATION ROOM, AT RIGHT. PART OF MAZE ENTRY IS VISIBLE INSIDE VAULT DOORWAY. INL NEGATIVE NO. 7763. Unknown Photographer, photo was dated as 3/30/1953, but this was probably an error. The more likely date is 3/30/1952. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
5. INTERIOR SHOWING WOOD STORAGE CABINETS AND 2LIGHT OVER 2LIGHT, ...
5. INTERIOR SHOWING WOOD STORAGE CABINETS AND 2-LIGHT OVER 2-LIGHT, DOUBLE-HUNG, WOOD-FRAMED WINDOW THROUGH SOUTHEAST WALL AT PHOTO CENTER. VIEW TO SOUTHEAST. - Bishop Creek Hydroelectric System, Plant 4, Lightning Arrestor Vault, Bishop Creek, Bishop, Inyo County, CA
View looking SW at brick retaining wall running parallel to ...
View looking SW at brick retaining wall running parallel to Jones Street showing bricked up storage vaults - Central of Georgia Railway, Savannah Repair Shops & Terminal Facilities, Brick Storage Vaults under Jones Street, Bounded by West Broad, Jones, West Boundary & Hull Streets, Savannah, Chatham County, GA
Dry-vault storage of spent fuel at the CASCAD facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baillif, L.; Guay, M.
A new modular dry storage vault concept using vertical metallic wells cooled by natural convection has been developed by the Commissariat a l'Energie Atomique and Societe Generale pour les Techniques Nouvelles to accommodate special fuels for high-level wastes. Basic specifications and design criteria have been followed to guarantee a double containment system and cooling to maintain the fuel below an acceptable temperature. The double containment is provided by two static barriers: At the reactor, fuels are placed in containers playing the role of the first barrier; the storage wells constitute the second barrier. Spent fuel placed in wells is cooledmore » by natural convection: a boundary layer is created along the outer side of the well. The heated air rises along the well leading to a thermosiphon flow that extracts the heat released. For heat transfer, studies, computations, and experimental tests have been carried out to calculate and determine the temperature of the containers and the fuel rod temperatures in various situations. The CASCAD vault storage can be applied to light water reactor (LWR) fuels without any difficulties if two requirements are satisfied: (1) Spend fuels have to be inserted in tight canisters. (2) Spent fuels have to be received only after a minimum decay time of 5 yr.« less
SnoVault and encodeD: A novel object-based storage system and applications to ENCODE metadata.
Hitz, Benjamin C; Rowe, Laurence D; Podduturi, Nikhil R; Glick, David I; Baymuradov, Ulugbek K; Malladi, Venkat S; Chan, Esther T; Davidson, Jean M; Gabdank, Idan; Narayana, Aditi K; Onate, Kathrina C; Hilton, Jason; Ho, Marcus C; Lee, Brian T; Miyasato, Stuart R; Dreszer, Timothy R; Sloan, Cricket A; Strattan, J Seth; Tanaka, Forrest Y; Hong, Eurie L; Cherry, J Michael
2017-01-01
The Encyclopedia of DNA elements (ENCODE) project is an ongoing collaborative effort to create a comprehensive catalog of functional elements initiated shortly after the completion of the Human Genome Project. The current database exceeds 6500 experiments across more than 450 cell lines and tissues using a wide array of experimental techniques to study the chromatin structure, regulatory and transcriptional landscape of the H. sapiens and M. musculus genomes. All ENCODE experimental data, metadata, and associated computational analyses are submitted to the ENCODE Data Coordination Center (DCC) for validation, tracking, storage, unified processing, and distribution to community resources and the scientific community. As the volume of data increases, the identification and organization of experimental details becomes increasingly intricate and demands careful curation. The ENCODE DCC has created a general purpose software system, known as SnoVault, that supports metadata and file submission, a database used for metadata storage, web pages for displaying the metadata and a robust API for querying the metadata. The software is fully open-source, code and installation instructions can be found at: http://github.com/ENCODE-DCC/snovault/ (for the generic database) and http://github.com/ENCODE-DCC/encoded/ to store genomic data in the manner of ENCODE. The core database engine, SnoVault (which is completely independent of ENCODE, genomic data, or bioinformatic data) has been released as a separate Python package.
SnoVault and encodeD: A novel object-based storage system and applications to ENCODE metadata
Podduturi, Nikhil R.; Glick, David I.; Baymuradov, Ulugbek K.; Malladi, Venkat S.; Chan, Esther T.; Davidson, Jean M.; Gabdank, Idan; Narayana, Aditi K.; Onate, Kathrina C.; Hilton, Jason; Ho, Marcus C.; Lee, Brian T.; Miyasato, Stuart R.; Dreszer, Timothy R.; Sloan, Cricket A.; Strattan, J. Seth; Tanaka, Forrest Y.; Hong, Eurie L.; Cherry, J. Michael
2017-01-01
The Encyclopedia of DNA elements (ENCODE) project is an ongoing collaborative effort to create a comprehensive catalog of functional elements initiated shortly after the completion of the Human Genome Project. The current database exceeds 6500 experiments across more than 450 cell lines and tissues using a wide array of experimental techniques to study the chromatin structure, regulatory and transcriptional landscape of the H. sapiens and M. musculus genomes. All ENCODE experimental data, metadata, and associated computational analyses are submitted to the ENCODE Data Coordination Center (DCC) for validation, tracking, storage, unified processing, and distribution to community resources and the scientific community. As the volume of data increases, the identification and organization of experimental details becomes increasingly intricate and demands careful curation. The ENCODE DCC has created a general purpose software system, known as SnoVault, that supports metadata and file submission, a database used for metadata storage, web pages for displaying the metadata and a robust API for querying the metadata. The software is fully open-source, code and installation instructions can be found at: http://github.com/ENCODE-DCC/snovault/ (for the generic database) and http://github.com/ENCODE-DCC/encoded/ to store genomic data in the manner of ENCODE. The core database engine, SnoVault (which is completely independent of ENCODE, genomic data, or bioinformatic data) has been released as a separate Python package. PMID:28403240
Active Sites Environmental Monitoring Program: Mid-FY 1991 report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashwood, T.L.; Wickliff, D.S.; Morrissey, C.M.
1991-10-01
This report summarizes the activities of the Active Sites Environmental Monitoring Program (ASEMP) from October 1990 through March 1991. The ASEMP was established in 1989 by Solid Waste Operations and the Environmental Sciences Division to provide early detection and performance monitoring at active low-level radioactive waste (LLW) disposal sites in Solid Waste Storage Area (SWSA) 6 and transuranic (TRU) waste storage sites in SWSA 5 as required by chapters II and III of US Department of Energy Order 5820.2A. Monitoring results continue to demonstrate the no LLW is being leached from the storage vaults on the tumulus pads. Loading ofmore » vaults on Tumulus II began during this reporting period and 115 vaults had been loaded by the end of March 1991.« less
NASA Astrophysics Data System (ADS)
Cardarelli, E.; Bargar, J.; Dam, W. L.; Francis, C.
2016-12-01
The storage vaults for low and intermediate-level short-lived radioactive waste in the East of France are settled on the Aptian sand layer. In the context of the periodic examination by the nuclear regulators, it has been recommended to assess more precisely the chemical conditions for a potential release of radionuclides in the underlying water table. In particular, this study aims at assessing the eventuality of spreading an alkaline plume in the Aptian sand pore water by the chemical degradation of the vault cementitious materials. The numerical approach developed for this purpose is supported by both experimental characterizations of tracers in the water table and results from preliminary numerical studies on the hydrology of the site and the hydraulic evolution of the storage. The results from these specific simulations were simplified in the reactive transport model to focus on the mechanistic description of the chemical processes taking place in the waste and vaults and on their consequences on the underlying water table. During the operating period of the disposal, the reactive transport modelling shows that the low water saturation in the vaults material and in the vadose zone prevents the aquifer from a significant increase of the water pH under the cement-based vaults. These results are in reasonable agreement with the pH regularly measured in the underlying water table. After storage closure, during the few hundred years of the monitoring period and furthermore beyond, the reactive transport modelling shows a noticeable release of hydroxyls and alkali ions under the disposal vaults and their spread downstream the storage site leading to pH values above 10. It is noteworthy that the pH is not buffered in the Aptian sands because of their low amount in clayey minerals. This effect is now considered for pH-sensitive radionuclide solutes in safety assessment calculations by weighting correspondingly their retention parameters.
NASA Astrophysics Data System (ADS)
Cochepin, B.; Munier, I.; MADE, B.
2017-12-01
The storage vaults for low and intermediate-level short-lived radioactive waste in the East of France are settled on the Aptian sand layer. In the context of the periodic examination by the nuclear regulators, it has been recommended to assess more precisely the chemical conditions for a potential release of radionuclides in the underlying water table. In particular, this study aims at assessing the eventuality of spreading an alkaline plume in the Aptian sand pore water by the chemical degradation of the vault cementitious materials. The numerical approach developed for this purpose is supported by both experimental characterizations of tracers in the water table and results from preliminary numerical studies on the hydrology of the site and the hydraulic evolution of the storage. The results from these specific simulations were simplified in the reactive transport model to focus on the mechanistic description of the chemical processes taking place in the waste and vaults and on their consequences on the underlying water table. During the operating period of the disposal, the reactive transport modelling shows that the low water saturation in the vaults material and in the vadose zone prevents the aquifer from a significant increase of the water pH under the cement-based vaults. These results are in reasonable agreement with the pH regularly measured in the underlying water table. After storage closure, during the few hundred years of the monitoring period and furthermore beyond, the reactive transport modelling shows a noticeable release of hydroxyls and alkali ions under the disposal vaults and their spread downstream the storage site leading to pH values above 10. It is noteworthy that the pH is not buffered in the Aptian sands because of their low amount in clayey minerals. This effect is now considered for pH-sensitive radionuclide solutes in safety assessment calculations by weighting correspondingly their retention parameters.
3. AERIAL VIEW, LOOKING SOUTH, OF BUILDING 371 BASEMENT UNDER ...
3. AERIAL VIEW, LOOKING SOUTH, OF BUILDING 371 BASEMENT UNDER CONSTRUCTION. THE BASEMENT HOUSES HEATING, VENTILATION, AND AIR CONDITIONING EQUIPMENT AND MECHANICAL UTILITIES, THE UPPER PART OF THE PLUTONIUM STORAGE VAULT AND MAINTENANCE BAY, AND SMALL PLUTONIUM PROCESSING AREAS. THE BASEMENT LEVEL IS DIVIDED INTO NEARLY EQUAL NORTH AND SOUTH PARTS BY THE UPPER PORTION OF THE PLUTONIUM STORAGE VAULT. (10/7/74) - Rocky Flats Plant, Plutonium Recovery Facility, Northwest portion of Rocky Flats Plant, Golden, Jefferson County, CO
13. SIDE VIEW OF THE STACKERRETRIEVER CRANE FROM THE TRANSFER ...
13. SIDE VIEW OF THE STACKER-RETRIEVER CRANE FROM THE TRANSFER BAY. THE STACKER-RETRIEVER IS A REMOTELY-OPERATED, MECHANIZED TRANSPORT SYSTEM FOR RETRIEVING PLUTONIUM CONTAINERS FROM THE STORAGE VAULT. (1/80) - Rocky Flats Plant, Plutonium Recovery Facility, Northwest portion of Rocky Flats Plant, Golden, Jefferson County, CO
Code of Federal Regulations, 2014 CFR
2014-01-01
... 5 Administrative Personnel 3 2014-01-01 2014-01-01 false Storage. 1312.25 Section 1312.25... Information § 1312.25 Storage. All classified material in the possession of OMB will be stored in a GSA-approved container or in vault-type rooms approved for Top Secret storage. Under the direction of the EOP...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Storage. 1312.25 Section 1312.25... Information § 1312.25 Storage. All classified material in the possession of OMB will be stored in a GSA-approved container or in vault-type rooms approved for Top Secret storage. Under the direction of the EOP...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 5 Administrative Personnel 3 2011-01-01 2011-01-01 false Storage. 1312.25 Section 1312.25... Information § 1312.25 Storage. All classified material in the possession of OMB will be stored in a GSA-approved container or in vault-type rooms approved for Top Secret storage. Under the direction of the EOP...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 5 Administrative Personnel 3 2013-01-01 2013-01-01 false Storage. 1312.25 Section 1312.25... Information § 1312.25 Storage. All classified material in the possession of OMB will be stored in a GSA-approved container or in vault-type rooms approved for Top Secret storage. Under the direction of the EOP...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 5 Administrative Personnel 3 2012-01-01 2012-01-01 false Storage. 1312.25 Section 1312.25... Information § 1312.25 Storage. All classified material in the possession of OMB will be stored in a GSA-approved container or in vault-type rooms approved for Top Secret storage. Under the direction of the EOP...
DOE Office of Scientific and Technical Information (OSTI.GOV)
HOPKINS, A.M.
2007-02-20
The 241-Z treatment and storage tanks, a hazardous waste Treatment, Storage and Disposal (TSD) unit permitted pursuant to the ''Resource Conservation and Recovery Act of 1976'' (RCRA) and Washington State ''Hazardous Waste Management Act, RCW 70.105'', have been deactivated and are being actively decommissioned. The 241-Z TSD unit managed non-listed radioactive contaminated waste water, containing trace RCRA characteristic constituents. The 241-Z TSD unit consists of below grade tanks (D-4, D-5, D-7, D-8, and an overflow tank) located in a concrete containment vault, sample glovebox GB-2-241-ZA, and associated ancillary piping and equipment. The tank system is located beneath the 241-Z building.more » The 241-Z building is not a portion of the TSD unit. The sample glovebox is housed in the above-grade building. Waste managed at the TSD unit was received via underground mining from Plutonium Finishing Plant (PFP) sources. Tank D-6, located in the D-6 vault cell, is a past-practice tank that was taken out of service in 1972 and has never operated as a portion of the RCRA TSD unit. CERCLA actions address Tank D-6, its containment vault cell, and soil beneath the cell that was potentially contaminated during past-practice operations and any other potential past-practice contamination identified during 241-Z closure, while outside the scope of the ''Hanford Facility Dangerous Waste Closure Plant, 241-Z Treatment and Storage Tanks''.« less
1972-01-01
This image, with callouts, depicts the storage area of the forward compartment at the upper level of the Orbital Workshop (OWS). The upper level consisted of a large work area and housed water storage tanks, a food freezer, storage vaults for film, scientific airlocks, mobility and stability experiment equipment, and other experimental equipment.
4. Exterior view of Components Test Laboratory (T27), looking northeast. ...
4. Exterior view of Components Test Laboratory (T-27), looking northeast. The building wing on the left houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault, and that on the right houses Test Cell 10 (environmental). - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO
5. Exterior view of Components Test Laboratory (T27), looking northwest. ...
5. Exterior view of Components Test Laboratory (T-27), looking northwest. The building wing on the left houses Test Cell 10 (environmental), and that on the right houses Test Cell 9 (fuel) and the fuel storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO
2. Exterior view of Components Test Laboratory (T27), looking southeast. ...
2. Exterior view of Components Test Laboratory (T-27), looking southeast. The building wing on the left houses the equipment room and that on the right houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO
3. Exterior view of Components Test Laboratory (T27), looking southeast. ...
3. Exterior view of Components Test Laboratory (T-27), looking southeast. The building wing on the left houses the equipment room, and that on the right houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO
Storage Area (1942 section), looking east, showing concrete structural elements ...
Storage Area (1942 section), looking east, showing concrete structural elements and wall opening to vaults - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC
DOE Office of Scientific and Technical Information (OSTI.GOV)
B. Gardiner; L.Graton; J.Longo
Classified removable electronic media (CREM) are tracked in several different ways at the Laboratory. To ensure greater security for CREM, we are creating a single, Laboratory-wide system to track CREM. We are researching technology that can be used to electronically tag and detect CREM, designing a database to track the movement of CREM, and planning to test the system at several locations around the Laboratory. We focus on affixing ''smart tags'' to items we want to track and installing gates at pedestrian portals to detect the entry or exit of tagged items. By means of an enterprise database, the systemmore » will track the entry and exit of tagged items into and from CREM storage vaults, vault-type rooms, access corridors, or boundaries of secure areas, as well as the identity of the person carrying an item. We are considering several options for tracking items that can give greater security, but at greater expense.« less
1972-01-01
This photograph, with callouts, depicts the experiment area of the forward compartment at the upper level of the Orbital Workshop. The upper level consisted of a large work area and housed water storage tanks, a food freezer, storage vaults for film, scientific airlocks, mobility and stability experiment equipment, and other experimental equipment.
Seismic analyses of equipment in 2736-Z complex. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ocoma, E.C.
1995-04-01
This report documents the structural qualification for the existing equipment when subjected to seismic loading in the Plutonium Storage Complex. It replaces in entirety Revision 0 and reconciles the U.S. Department of Energy (DOE) comments on Revision 0. The Complex consists of 2736-Z Building (plutonium storage vault), 2736-ZA Building (vault ventilation equipment building), and 2736-ZB Building (shipping/receiving, repackaging activities). The existing equipment structurally qualified in this report are the metal storage racks for 7 inch and lard cans in room 2 of Building 2736-Z; the cubicles, can holders and pedestals in rooms 1, 3, and 4 of Building 2736-Z; themore » ventilation duct including exhaust fans/motors, emergency diesel generator, and HEPA filter housing in Building 2736-ZA; the repackaging glovebox in Building 2736-ZB; and the interface duct between Buildings 2736-Z and 2736-ZA.« less
Classification of the Inventory of Spent Sealed Sources at INSHAS Storage Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
El-Adham, K.; Geleel, M.A.; Mahmoud, N.S.
2006-07-01
The Egyptian Atomic Energy Authority (EAEA) is responsible for the recovery, transportation, conditioning, storage and disposal of all unwanted spent sealed radioactive sources (SSSs) in Egypt. Because of radioactive decay, damage, misuse or changing technical conditions, approximately 600 unwanted SSSs are now in storage at the EAEA's Hot-Laboratories Center in INSHAS. For the safe recovery, transportation, conditioning and storage of these unwanted SSSs the EAEA uses an International Atomic Energy Agency's (IAEA's) categorization system. The IAEA system classifies sealed radioactive sources (SRSs) into five categories based on potential risks to current workers and the public. This IAEA system allows Membermore » States like Egypt to apply a graded approach to the management of SRSs and SSSs. With over 600 unwanted SSSs already in storage, the EAEA is planned to dispose unwanted SSSs in near surface vault structures with solidified low- and intermediate-level radioactive wastes. The IAEA's categorization system is not designed to protect future populations from the possible long-term migration of radioactive wastes from a disposal system. This paper presents the basis of a second categorization system, designed to protect the public in Egypt from radioactive wastes that may migrate from a near-surface disposal facility. Assuming a release of radionuclides from the near-surface vaults 150 years after disposal and consumption of contaminated groundwater at the 150 m fence-line, this classification systems ranks SSSs into two groups: Those appropriate for near-surface disposal and those SSSs requiring greater isolation. Intermediate depth borehole disposal is proposed for those SSSs requiring greater isolation. Assistance with intermediate-depth borehole disposal is being provided by the Integrated Management Program for Radioactive Sealed Sources (IMPRSS) and by the IAEA through a Technical Cooperation Project. IMPRSS is a joint Egyptian / U.S. program that is greatly improving the cradle-to-grave management of SRSs and SSSs in Egypt. As a component of IMPRSS, Sandia National Laboratories is transferring knowledge to the Egyptian counterparts from implementation of the Greater Confinement Disposal boreholes in the U.S. (authors)« less
The growth of the UniTree mass storage system at the NASA Center for Computational Sciences
NASA Technical Reports Server (NTRS)
Tarshish, Adina; Salmon, Ellen
1993-01-01
In October 1992, the NASA Center for Computational Sciences made its Convex-based UniTree system generally available to users. The ensuing months saw the growth of near-online data from nil to nearly three terabytes, a doubling of the number of CPU's on the facility's Cray YMP (the primary data source for UniTree), and the necessity for an aggressive regimen for repacking sparse tapes and hierarchical 'vaulting' of old files to freestanding tape. Connectivity was enhanced as well with the addition of UltraNet HiPPI. This paper describes the increasing demands placed on the storage system's performance and throughput that resulted from the significant augmentation of compute-server processor power and network speed.
Hanford Spent Nuclear Fuel Project recommended path forward
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fulton, J.C.
The Spent Nuclear Fuel Project (the Project), in conjunction with the U.S. Department of Energy-commissioned Independent Technical Assessment (ITA) team, has developed engineered alternatives for expedited removal of spent nuclear fuel, including sludge, from the K Basins at Hanford. These alternatives, along with a foreign processing alternative offered by British Nuclear Fuels Limited (BNFL), were extensively reviewed and evaluated. Based on these evaluations, a Westinghouse Hanford Company (WHC) Recommended Path Forward for K Basins spent nuclear fuel has been developed and is presented in Volume I of this document. The recommendation constitutes an aggressive series of projects to construct andmore » operate systems and facilities to safely retrieve, package, transport, process, and store K Basins fuel and sludge. The overall processing and storage scheme is based on the ITA team`s proposed passivation and vault storage process. A dual purpose staging and vault storage facility provides an innovative feature which allows accelerated removal of fuel and sludge from the basins and minimizes programmatic risks beyond any of the originally proposed alternatives. The projects fit within a regulatory and National Environmental Policy Act (NEPA) overlay which mandates a two-phased approach to construction and operation of the needed facilities. The two-phase strategy packages and moves K Basins fuel and sludge to a newly constructed Staging and Storage Facility by the year 2000 where it is staged for processing. When an adjoining facility is constructed, the fuel is cycled through a stabilization process and returned to the Staging and Storage Facility for dry interim (40-year) storage. The estimated total expenditure for this Recommended Path Forward, including necessary new construction, operations, and deactivation of Project facilities through 2012, is approximately $1,150 million (unescalated).« less
1. View, structures in Systems Integration Laboratory complex, looking northwest. ...
1. View, structures in Systems Integration Laboratory complex, looking northwest. The twin gantry structure in the center is the Systems Integration Laboratory (T-28). To its immediate left in the foreground is a truck well, concrete retaining wall, piping, and stack associated with the oxidizer vault storage area. To the immediate right of T-28 is the concrete Signal Transfer Building (T-28A). At the extreme right is the Long-Term Hydrazine Silo (T-28E). - Air Force Plant PJKS, Systems Integration Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlson, T.A., Fluor Daniel Hanford
1997-02-06
The Immobilized Low-Activity Waste Interim Storage subproject will provide storage capacity for immobilized low-activity waste product sold to the U.S. Department of Energy by the privatization contractor. This statement of work describes the work scope (encompassing definition of new installations and retrofit modifications to four existing grout vaults), to be performed by the Architect-Engineer, in preparation of a conceptual design for the Immobilized Low-Activity Waste Interim Storage Facility.
1. Exterior view of Components Test Laboratory (T27), looking southeast ...
1. Exterior view of Components Test Laboratory (T-27), looking southeast from hill north of structure. The building wing in the right foreground houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. Test Cell 10 is located in the center background, Test Cell 9 is at the far left, and the equipment room is in the immediate left foreground. The control room is in the center of the structure and abuts the aforementioned test cell and equipment room wings. This structure served as a facility for testing, handling, and storage of Titan II's hydrazine- and nitrogen teteroxide-based propellant system components for compatability determinations. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO
Inertial Manifolds for Navier-Stokes Equations and Related Dynamical Systems
1991-05-31
Graphics IRIS (SGI). The RLE files for the animation are loaded to an Abekas and recorded to tape by Betacam . This computational work was done by using the...scripts and comments, are loaded to the Abekas-A60 digital image storage device, and then recorded to the Betacam BVW-75 analog tape recorder. Static...interfacing, huge data files are output to the Data Vault parallelly with little cost. In addition to the SGIs, Abekas, Betacam and Solitaire, the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mattlin, E.; Charboneau, S.; Johnston, G.
2007-07-01
The 241-Z treatment and storage tanks, a hazardous waste Treatment, Storage and Disposal (TSD) unit permitted pursuant to the Resource Conservation and Recovery Act of 1976 (RCRA) and Washington State Hazardous Waste Management Act, RCW 70.105, , have been deactivated and are being actively decommissioned under the provisions of the Hanford Federal Facility Agreement and Consent Order (HFFACO), RCRA and Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) 42 U.S.C. 9601 et seq. The 241-Z TSD unit managed non-listed radioactive contaminated waste water, containing trace RCRA characteristic constituents. The 241-Z TSD unit consists of below grade tanks (D-4,more » D-5, D-7, D-8, and an overflow tank) located in a concrete containment vault, sample glovebox GB-2-241-ZA, and associated ancillary piping and equipment. The tank system is located beneath the 241-Z building. The 241-Z building is not a portion of the TSD unit. The sample glovebox is housed in the above-grade building. Waste managed at the TSD unit was received via underground piping from Plutonium Finishing Plant (PFP) sources. Tank D-6, located in the D-6 vault cell, is a past-practice tank that was taken out of service in 1972 and has never operated as a portion of the RCRA TSD unit. CERCLA actions will address Tank D-6, its containment vault cell, and soil beneath the cell that was potentially contaminated during past-practice operations and any other potential past-practice contamination identified during 241-Z closure, while outside the scope of the Hanford Facility Dangerous Waste Closure Plan, 241-Z Treatment and Storage Tanks. Under the RCRA closure plan, the 241-Z TSD unit is anticipated to undergo clean closure to the performance standards of the State of Washington with respect to dangerous waste contamination from RCRA operations. The TSD unit will be clean closed if physical closure activities identified in the plan achieve clean closure standards for all 241-Z locations. Clean closed 241-Z treatment and storage tanks, equipment and/or structures will remain after RCRA clean closure for future disposition in conjunction with PFP decommissioning activities which are integrated with CERCLA. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lockie, K.A.; Suttora, L.C.; Quigley, K.D.
2007-07-01
Significant progress has been made at the U.S. Department of Energy (DOE) Idaho National Laboratory (INL) to clean and close emptied radioactive liquid waste storage tanks at the Idaho Nuclear Technology and Engineering Center (INTEC) Tank Farm Facility (TFF). The TFF includes eleven 1,135.6-kL (300,000-gal) underground stainless steel storage tanks and four smaller, 113.5-kL (30,000-gal) stainless steel tanks, along with tank vaults, interconnecting piping, and ancillary equipment. The TFF tanks have historically been used to store a variety of radioactive liquid waste, including wastes associated with past spent nuclear fuel reprocessing. Although four of the large storage tanks remain inmore » use for waste storage, the other seven 1,135.6-kL (300,000-gal) tanks and the four 113.5-kL (30,000-gal) tanks have been emptied of waste and cleaned in preparation of final closure. A water spray cleaning system was developed and deployed to clean internal tank surfaces and remove remaining tank wastes. The cleaning system was effective in removing all but a very small volume of solid residual waste particles. Recent issuance of an Amended Record of Decision (ROD) in accordance with the National Environmental Policy Act, and a Waste Determination complying with Section 3116 of the Ronald W. Reagan National Defense Authorization Act (NDAA) for Fiscal Year 2005, has allowed commencement of grouting activities on the cleaned tanks. In November 2006, three of the 113.5-kL (30,000-gal) tanks were filled with grout to provide long-term stability. It is currently planned that all seven cleaned 1,135.6-kL (300,000-gal) tanks, as well as the four 113.5-kL (30,000-gal) tanks and all associated tank vaults and interconnecting piping, will be stabilized with grout as early as 2008. (authors)« less
Aitken, Steven B; Butler, Richard; Butterworth, Steven W; Quigley, Keith D
2005-05-01
Bechtel BWXT Idaho, Maintenance and Operating Contractor for the Department of Energy at the Idaho National Engineering and Environmental Laboratory, has emptied, cleaned, and sampled six of the eleven 1.135 x 10(6) L high level waste underground storage tanks at the Idaho Nuclear Technology and Engineering Center, well ahead of the State of Idaho Consent Order cleaning schedule. Cleaning of a seventh tank is expected to be complete by the end of calendar year 2004. The tanks, with associated vaults, valve boxes, and distribution systems, are being closed to meet Resource Conservation and Recovery Act regulations and Department of Energy orders. The use of remotely operated equipment placed in the tanks through existing tank riser access points, sampling methods and application of as-low-as-reasonably-achievable (ALARA) principles have proven effective in keeping personnel dose low during equipment removal, tank, vault, and valve box cleaning, and sampling activities, currently at 0.03 Sv.
Immobilization of recombinant vault nanoparticles on solid substrates.
Xia, Yun; Ramgopal, Yamini; Li, Hai; Shang, Lei; Srinivas, Parisa; Kickhoefer, Valerie A; Rome, Leonard H; Preiser, Peter R; Boey, Freddy; Zhang, Hua; Venkatraman, Subbu S
2010-03-23
Native vaults are nanoscale particles found abundantly in the cytoplasm of most eukaryotic cells. They have a capsule-like structure with a thin shell surrounding a "hollow" interior compartment. Recombinant vault particles were found to self-assemble following expression of the major vault protein (MVP) in a baculovirus expression system, and these particles are virtually identical to native vaults. Such particles have been recently studied as potential delivery vehicles. In this study, we focus on immobilization of vault particles on a solid substrate, such as glass, as a first step to study their interactions with cells. To this end, we first engineered the recombinant vaults by fusing two different tags to the C-terminus of MVP, a 3 amino acid RGD peptide and a 12 amino acid RGD-strep-tag peptide. We have demonstrated two strategies for immobilizing vaults on solid substrates. The barrel-and-cap structure of vault particles was observed for the first time, by atomic force microscopy (AFM), in a dry condition. This work proved the feasibility of immobilizing vault nanoparticles on a material surface, and the possibility of using vault nanoparticles as localized and sustainable drug carriers as well as a biocompatible surface moiety.
DOE Office of Scientific and Technical Information (OSTI.GOV)
HOLLENBECK, R.G.
The Spent Nuclear Fuel (SNF) Canister Storage Building (CSB) is the interim storage facility for the K-Basin SNF at the US. Department of Energy (DOE) Hanford Site. The SNF is packaged in multi-canister overpacks (MCOs). The MCOs are placed inside transport casks, then delivered to the service station inside the CSB. At the service station, the MCO handling machine (MHM) moves the MCO from the cask to a storage tube or one of two sample/weld stations. There are 220 standard storage tubes and six overpack storage tubes in a below grade reinforced concrete vault. Each storage tube can hold twomore » MCOs.« less
A new method for generating an invariant iris private key based on the fuzzy vault system.
Lee, Youn Joo; Park, Kang Ryoung; Lee, Sung Joo; Bae, Kwanghyuk; Kim, Jaihie
2008-10-01
Cryptographic systems have been widely used in many information security applications. One main challenge that these systems have faced has been how to protect private keys from attackers. Recently, biometric cryptosystems have been introduced as a reliable way of concealing private keys by using biometric data. A fuzzy vault refers to a biometric cryptosystem that can be used to effectively protect private keys and to release them only when legitimate users enter their biometric data. In biometric systems, a critical problem is storing biometric templates in a database. However, fuzzy vault systems do not need to directly store these templates since they are combined with private keys by using cryptography. Previous fuzzy vault systems were designed by using fingerprint, face, and so on. However, there has been no attempt to implement a fuzzy vault system that used an iris. In biometric applications, it is widely known that an iris can discriminate between persons better than other biometric modalities. In this paper, we propose a reliable fuzzy vault system based on local iris features. We extracted multiple iris features from multiple local regions in a given iris image, and the exact values of the unordered set were then produced using the clustering method. To align the iris templates with the new input iris data, a shift-matching technique was applied. Experimental results showed that 128-bit private keys were securely and robustly generated by using any given iris data without requiring prealignment.
1970-01-01
This photograph was taken during assembly of the bottom and upper floors of the Skylab Orbital Workshop (OWS). The OWS was divided into two major compartments. The lower level provided crew accommodations for sleeping, food preparation and consumption, hygiene, waste processing and disposal, and performance of certain experiments. The upper level consisted of a large work area and housed water storage tanks, a food freezer, storage vaults for film, scientific airlocks, mobility and stability experiment equipment, and other experimental equipment.
One corner of the third floor has examples of Edison ...
One corner of the third floor has examples of Edison motion picture projectors in rather poor condition. Better preserved examples are in storage in Vault #12. - Thomas A. Edison Laboratories, Building No. 5, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
44. Building 102, view from mezzanine looking down to first ...
44. Building 102, view from mezzanine looking down to first floor showing Klystron tube equipment vaults with dual waveguides leaving top of vaults through bifurcation combiner system at start of waveguides; note tops of capacitor vaults along photograph to left. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
NASA Astrophysics Data System (ADS)
Alexander, G. H.; Cooper, D. L.; Cummings, C. A.; Reiber, E. E.
1981-10-01
Low cost energy storage assemblies were developed. In the search for low overall cost assemblies, many diverse concepts and materials were postulated and briefly evaluated. Cost rankings, descriptions, and discussions of the concepts were presented from which ORNL selected the following three concepts for the Phase 2 development: (1) a site constructed tank with reinforced concrete walls formed with specialized modular blocks which eliminates most concrete form work and provides integral R-20 insulation designated ORNLFF; (2) a site constructed tank with earth supported walls that are formed from elements common to residential, in-ground swimming pools, designated SWPL; (3) and a site assembled tank used in underground utility vaults, designated UTLBX. Detailed designs of free standing versions of the three concepts are presented.
Engineering of vault nanocapsules with enzymatic and fluorescent properties
Kickhoefer, Valerie A.; Garcia, Yvette; Mikyas, Yeshi; Johansson, Erik; Zhou, Jing C.; Raval-Fernandes, Sujna; Minoofar, Payam; Zink, Jeffrey I.; Dunn, Bruce; Stewart, Phoebe L.; Rome, Leonard H.
2005-01-01
One of the central issues facing the emerging field of nanotechnology is cellular compatibility. Nanoparticles have been proposed for diagnostic and therapeutic applications, including drug delivery, gene therapy, biological sensors, and controlled catalysis. Viruses, liposomes, peptides, and synthetic and natural polymers have been engineered for these applications, yet significant limitations continue to prevent their use. Avoidance of the body's natural immune system, lack of targeting specificity, and the inability to control packaging and release are remaining obstacles. We have explored the use of a naturally occurring cellular nanoparticle known as the vault, which is named for its morphology with multiple arches reminiscent of cathedral ceilings. Vaults are 13-MDa ribonucleoprotein particles with an internal cavity large enough to sequester hundreds of proteins. Here, we report a strategy to target and sequester biologically active materials within the vault cavity. Attachment of a vault-targeting peptide to two proteins, luciferase and a variant of GFP, resulted in their sequestration within the vault cavity. The targeted proteins confer enzymatic and fluorescent properties on the recombinant vaults, both of which can be detected by their emission of light. The modified vaults are compatible with living cells. The ability to engineer vault particles with designed properties and functionalities represents an important step toward development of a biocompatible nanocapsule. PMID:15753293
Engineering of vault nanocapsules with enzymatic and fluorescent properties.
Kickhoefer, Valerie A; Garcia, Yvette; Mikyas, Yeshi; Johansson, Erik; Zhou, Jing C; Raval-Fernandes, Sujna; Minoofar, Payam; Zink, Jeffrey I; Dunn, Bruce; Stewart, Phoebe L; Rome, Leonard H
2005-03-22
One of the central issues facing the emerging field of nanotechnology is cellular compatibility. Nanoparticles have been proposed for diagnostic and therapeutic applications, including drug delivery, gene therapy, biological sensors, and controlled catalysis. Viruses, liposomes, peptides, and synthetic and natural polymers have been engineered for these applications, yet significant limitations continue to prevent their use. Avoidance of the body's natural immune system, lack of targeting specificity, and the inability to control packaging and release are remaining obstacles. We have explored the use of a naturally occurring cellular nanoparticle known as the vault, which is named for its morphology with multiple arches reminiscent of cathedral ceilings. Vaults are 13-MDa ribonucleoprotein particles with an internal cavity large enough to sequester hundreds of proteins. Here, we report a strategy to target and sequester biologically active materials within the vault cavity. Attachment of a vault-targeting peptide to two proteins, luciferase and a variant of GFP, resulted in their sequestration within the vault cavity. The targeted proteins confer enzymatic and fluorescent properties on the recombinant vaults, both of which can be detected by their emission of light. The modified vaults are compatible with living cells. The ability to engineer vault particles with designed properties and functionalities represents an important step toward development of a biocompatible nanocapsule.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-04-01
The US Department of Energy (DOE) proposes to construct and maintain additional storage capacity at Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee, for liquid low-level radioactive waste (LLLW). New capacity would be provided by a facility partitioned into six individual tank vaults containing one 100,000 gallon LLLW storage tank each. The storage tanks would be located within the existing Melton Valley Storage Tank (MVST) facility. This action would require the extension of a potable water line approximately one mile from the High Flux Isotope Reactor (HFIR) area to the proposed site to provide the necessary potable water for themore » facility including fire protection. Alternatives considered include no-action, cease generation, storage at other ORR storage facilities, source treatment, pretreatment, and storage at other DOE facilities.« less
MTR, TRA603. FIRST FLOOR PLAN. REACTOR AT CENTER. TWENTYMETER CHOPPER ...
MTR, TRA-603. FIRST FLOOR PLAN. REACTOR AT CENTER. TWENTY-METER CHOPPER HOUSE. COFFIN TURNING ROLLS. REMOVABLE PANEL OVER CANAL ON EAST SIDE. NEW PLUG STORAGE ACCESS. DOOR SCHEDULE INDICATES STEEL (FOR VAULT), WIRE MESH, AND HOLLOW METAL TYPES. STORAGE AND ISSUE ROOM. SAFETY SHOWERS. DOORWAY TO WING, TRA-604. BLAW-KNOX 3150-803-2, 7/1950. INL INDEX NO. 531-0603-00-098-100561, REV. 10. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
1970-01-01
This photograph was taken during installation of floor grids on the upper and lower floors inside the Skylab Orbital Workshop at the McDornell Douglas plant at Huntington Beach, California. The OWS was divided into two major compartments. The lower level provided crew accommodations for sleeping, food preparation and consumption, hygiene, waste processing and disposal, and performance of certain experiments. The upper level consisted of a large work area and housed water storage tanks, a food freezer, storage vaults for film, scientific airlocks, mobility and stability experiment equipment, and other experimental equipment.
The Miracle of Microfilm: The Foundation of the Largest Genealogical Record Collection in the World.
ERIC Educational Resources Information Center
Powell, Ted F.
1985-01-01
Traces origins of the Genealogical Department of The Church of Jesus Christ of Latter-Day Saints (Mormon), highlighting microfilm technology, equipment used, development of the 16mm camera, film processing, quality control, filming techniques, specialized microfilming, archival storage (The Granite Mountain Records Vault), the genealogical library…
Ieva, Antonio Di; Audigé, Laurent; Kellman, Robert M.; Shumrick, Kevin A.; Ringl, Helmut; Prein, Joachim; Matula, Christian
2014-01-01
The AOCMF Classification Group developed a hierarchical three-level craniomaxillofacial classification system with increasing level of complexity and details. The highest level 1 system distinguish four major anatomical units, including the mandible (code 91), midface (code 92), skull base (code 93), and cranial vault (code 94). This tutorial presents the level 2 and more detailed level 3 systems for the skull base and cranial vault units. The level 2 system describes fracture location outlining the topographic boundaries of the anatomic regions, considering in particular the endocranial and exocranial skull base surfaces. The endocranial skull base is divided into nine regions; a central skull base adjoining a left and right side are divided into the anterior, middle, and posterior skull base. The exocranial skull base surface and cranial vault are divided in regions defined by the names of the bones involved: frontal, parietal, temporal, sphenoid, and occipital bones. The level 3 system allows assessing fracture morphology described by the presence of fracture fragmentation, displacement, and bone loss. A documentation of associated intracranial diagnostic features is proposed. This tutorial is organized in a sequence of sections dealing with the description of the classification system with illustrations of the topographical skull base and cranial vault regions along with rules for fracture location and coding, a series of case examples with clinical imaging and a general discussion on the design of this classification. PMID:25489394
CBP [TASK 12] experimental study of the concrete salstone two-layer system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samson, Eric; Protiere, Yannick
This report presents the results of a study which intended to study the behavior of concrete samples placed in contact with a wasteform mixture bearing high level of sulfate in its pore solution. A setup was prepared which consisted in a wasteform poured on top of vault concrete mixes (identified as Vault 1/4 and Vault 2 mixes) cured for approximately 6 months.
Retrieval System for Calcined Waste for the Idaho Cleanup Project - 12104
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eastman, Randy L.; Johnston, Beau A.; Lower, Danielle E.
This paper describes the conceptual approach to retrieve radioactive calcine waste, hereafter called calcine, from stainless steel storage bins contained within concrete vaults. The retrieval system will allow evacuation of the granular solids (calcine) from the storage bins through the use of stationary vacuum nozzles. The nozzles will use air jets for calcine fluidization and will be able to rotate and direct the fluidization or displacement of the calcine within the bin. Each bin will have a single retrieval system installed prior to operation to prevent worker exposure to the high radiation fields. The addition of an articulated camera armmore » will allow for operations monitoring and will be equipped with contingency tools to aid in calcine removal. Possible challenges (calcine bridging and rat-holing) associated with calcine retrieval and transport, including potential solutions for bin pressurization, calcine fluidization and waste confinement, are also addressed. The Calcine Disposition Project has the responsibility to retrieve, treat, and package HLW calcine. The calcine retrieval system has been designed to incorporate the functions and technical characteristics as established by the retrieval system functional analysis. By adequately implementing the highest ranking technical characteristics into the design of the retrieval system, the system will be able to satisfy the functional requirements. The retrieval system conceptual design provides the means for removing bulk calcine from the bins of the CSSF vaults. Top-down vacuum retrieval coupled with an articulating camera arm will allow for a robust, contained process capable of evacuating bulk calcine from bins and transporting it to the processing facility. The system is designed to fluidize, vacuum, transport and direct the calcine from its current location to the CSSF roof-top transport lines. An articulating camera arm, deployed through an adjacent access riser, will work in conjunction with the retrieval nozzle to aid in calcine fluidization, remote viewing, clumped calcine breaking and recovery from off-normal conditions. As the design of the retrieval system progresses from conceptual to preliminary, increasing attention will be directed toward detailed design and proof-of- concept testing. (authors)« less
3. VIEW OF ADDITION TO BUILDING 444. IN THE MID ...
3. VIEW OF ADDITION TO BUILDING 444. IN THE MID 1950s, RADIOGRAPHY VAULTS, A GRAPHITE STORAGE AND CUTTING AREA, AND A GRAPHITE PRODUCTION PROCESSING AREA WERE ADDED TO BUILDING 444. (1956) - Rocky Flats Plant, Non-Nuclear Production Facility, South of Cottonwood Avenue, west of Seventh Avenue & east of Building 460, Golden, Jefferson County, CO
Interior View of the Orbital Workshop
NASA Technical Reports Server (NTRS)
1972-01-01
This photograph is an interior view of the Orbital Workshop (OWS) upper level looking from the airlock hatch, showing the octagonal opening that separated the workshop's two levels. The trash airlock can be seen at center. The lower level of the OWS provided crew accommodations for sleeping, food preparation and consumption, hygiene, waste processing and disposal, and performance of certain experiments. The upper level consisted of a large work area and housed water storage tanks, a food freezer, storage vaults for film, scientific airlocks, mobility and stability experiment equipment, and other experimental equipment.
Crystal gazing. Part 2: Implications of advanced in digital data storage technology
NASA Technical Reports Server (NTRS)
Wells, D. C.
1984-01-01
During the next 5-10 years it is likely that the bit density available in digital mass storage systems (magnetic tapes, optical and magnetic disks) will be increased to such an extent that it will greatly exceed that of the conventional photographic emulsions like IIIaJ which are used in astronomy. These developments imply that it will soon be advantageous for astronomers to use microdensitometers to completely digitize all photographic plates soon after they are developed. Distribution of digital copies of sky surveys and the contents of plate vaults will probably become feasible within ten years. Copies of other astronomical archieves (e.g., Space Telescope) could also be distributed with the same techniques. The implications for designers of future microdensitometers are: (1) there will be a continuing need for precision digitization of large-format photographic imagery, and (2) that the need for real-time analysis of the output of microdensitometers will decrease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandoval, D. M.; Strittmatter, R. B.; Abeyta, J. D.
2004-01-01
The initial objectives of this effort were to provide a hardware and software platform that can address the requirements for the accountability of classified removable electronic media and vault access logging. The Media Tracker system software assists classified media custodian in managing vault access logging and Media Tracking to prevent the inadvertent violation of rules or policies for the access to a restricted area and the movement and use of tracked items. The MediaTracker system includes the software tools to track and account for high consequence security assets and high value items. The overall benefits include: (1) real-time access tomore » the disposition of all Classified Removable Electronic Media (CREM), (2) streamlined security procedures and requirements, (3) removal of ambiguity and managerial inconsistencies, (4) prevention of incidents that can and should be prevented, (5) alignment with the DOE's initiative to achieve improvements in security and facility operations through technology deployment, and (6) enhanced individual responsibility by providing a consistent method of dealing with daily responsibilities. In response to initiatives to enhance the control of classified removable electronic media (CREM), the Media Tracker software suite was developed, piloted and implemented at the Los Alamos National Laboratory beginning in July 2000. The Media Tracker software suite assists in the accountability and tracking of CREM and other high-value assets. One component of the MediaTracker software suite provides a Laboratory-approved media tracking system. Using commercial touch screen and bar code technology, the MediaTracker (MT) component of the MediaTracker software suite provides an efficient and effective means to meet current Laboratory requirements and provides new-engineered controls to help assure compliance with those requirements. It also establishes a computer infrastructure at vault entrances for vault access logging, and can accommodate several methods of positive identification including smart cards and biometrics. Currently, we have three mechanisms that provide added security for accountability and tracking purposes. One mechanism consists of a portable, hand-held inventory scanner, which allows the custodian to physically track the items that are not accessible within a particular area. The second mechanism is a radio frequency identification (RFID) consisting of a monitoring portal, which tracks and logs in a database all activity tagged of items that pass through the portals. The third mechanism consists of an electronic tagging of a flash memory device for automated inventory of CREM in storage. By modifying this USB device the user is provided with added assurance, limiting the data from being obtained from any other computer.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ludwick, J D; Moore, E B
1984-01-01
Safety and cost information is developed for the conceptual decommissioning of five different types of reference independent spent fuel storage installations (ISFSIs), each of which is being given consideration for interim storage of spent nuclear fuel in the United States. These include one water basin-type ISFSI (wet) and four dry ISFSIs (drywell, silo, vault, and cask). The reference ISFSIs include all component parts necessary for the receipt, handling and storage of spent fuel in a safe and efficient manner. Three decommissioning alternatives are studied to obtain comparisons between costs (in 1981 dollars), occupational radiation doses, and potential radiation doses tomore » the public. The alternatives considered are: DECON (immediate decontamination), SAFSTOR (safe storage followed by deferred decontamination), and ENTOMB (entombment followed by long-term surveillance).« less
Gudelj, Ines; Babić, Vesna; Milat, Sanja; Čavala, Marijana; Zagorac, Siniša; Katić, Ratko
2015-07-01
The basic aim of this research was to determine the differences of kinematic parameters in two qualitatively different groups of young pole vaulters. With this purpose, a research was conducted in which the video records from a competition were acquired. The sample of entities (N = 71) consisted of successful vaults of 30 pole vaulters, whose attempts were recorded at the European Junior Championship in Novi Sad, held on 23-26th July 2009. The examinees performed the vaults as a part of the elimination competition for the finals, and during the final part of the competition. The age of examinees was from 17 to 19 years, and the span of their best results was from 4.70 to 5.30 meters. The kinematic analysis was conducted according to the standards of APAS procedure (Ariel Performance Analysis System, USA), determining 25 kinematic variables necessary for further analysis. The entities (vaults) were divided into two categories (qualitative classes) based on the expert knowledge. Group 1 consisted of successful vaults up to 4.90 m (N = 46), while group 2 consisted of successful vaults whose height was more than 4.90 m (N = 25). The discrimination analysis determined the parameters differentiating the vaults of different quantitative classes. Also, it was confirmed that the result efficiency in pole vault was primarily determined by the variables defined by motor abilities, as well as the indicators determining the vault performance technique.
Composite analysis E-area vaults and saltstone disposal facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, J.R.
1997-09-01
This report documents the Composite Analysis (CA) performed on the two active Savannah River Site (SRS) low-level radioactive waste (LLW) disposal facilities. The facilities are the Z-Area Saltstone Disposal Facility and the E-Area Vaults (EAV) Disposal Facility. The analysis calculated potential releases to the environment from all sources of residual radioactive material expected to remain in the General Separations Area (GSA). The GSA is the central part of SRS and contains all of the waste disposal facilities, chemical separations facilities and associated high-level waste storage facilities as well as numerous other sources of radioactive material. The analysis considered 114 potentialmore » sources of radioactive material containing 115 radionuclides. The results of the CA clearly indicate that continued disposal of low-level waste in the saltstone and EAV facilities, consistent with their respective radiological performance assessments, will have no adverse impact on future members of the public.« less
Vaults Engineered for Hydrophobic Drug Delivery
Buehler, Daniel C.; Toso, Daniel B.; Kickhoefer, Valerie A.; Zhou, Z. Hong
2013-01-01
The vault nanoparticle is one of the largest known ribonucleoprotein complexes in the sub-100 nm range. Highly conserved and almost ubiquitously expressed in eukaryotes, vaults form a large nanocapsule with a barrel-shaped morphology surrounding a large hollow interior. These properties make vaults an ideal candidate for development into a drug delivery vehicle. In this study, we report the first example of using vaults towards this goal. We engineered recombinant vaults to encapsulate the highly insoluble and toxic hydrophobic compound All-trans Retinoic Acid (ATRA) using a vault binding lipoprotein complex that forms a lipid bilayer nanodisk. These recombinant vaults offer protection to the encapsulated ATRA from external elements. Furthermore, a cryo-electron tomography (cryo-ET) reconstruction shows the vault binding lipoprotein complex sequestered within the vault lumen. Finally, these ATRA loaded vaults have enhanced cytotoxicity against the hepatocellular carcinoma cell line HepG2. The ability to package therapeutic compounds into the vault is an important achievement toward their development into a viable and versatile platform for drug delivery. PMID:21506266
Jackson, M I; Hiley, M J; Yeadon, M R
2011-10-13
In the table contact phase of gymnastics vaulting both dynamic and static friction act. The purpose of this study was to develop a method of simulating Coulomb friction that incorporated both dynamic and static phases and to compare the results with those obtained using a pseudo-Coulomb implementation of friction when applied to the table contact phase of gymnastics vaulting. Kinematic data were obtained from an elite level gymnast performing handspring straight somersault vaults using a Vicon optoelectronic motion capture system. An angle-driven computer model of vaulting that simulated the interaction between a seven segment gymnast and a single segment vaulting table during the table contact phase of the vault was developed. Both dynamic and static friction were incorporated within the model by switching between two implementations of the tangential frictional force. Two vaulting trials were used to determine the model parameters using a genetic algorithm to match simulations to recorded performances. A third independent trial was used to evaluate the model and close agreement was found between the simulation and the recorded performance with an overall difference of 13.5%. The two-state simulation model was found to be capable of replicating performance at take-off and also of replicating key contact phase features such as the normal and tangential motion of the hands. The results of the two-state model were compared to those using a pseudo-Coulomb friction implementation within the simulation model. The two-state model achieved similar overall results to those of the pseudo-Coulomb model but obtained solutions more rapidly. Copyright © 2011 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinke, R.G.; Mueller, C.; Knight, T.D.
1998-03-01
The computational fluid dynamics code CFX4.2 was used to evaluate steady-state thermal-hydraulic conditions in the Fluor Daniel, Inc., Nuclear Material Storage Facility renovation design (initial 30% of Title 1). Thirteen facility cases were evaluated with varying temperature dependence, drywell-array heat-source magnitude and distribution, location of the inlet tower, and no-flow curtains in the drywell-array vault. Four cases of a detailed model of the inlet-tower top fixture were evaluated to show the effect of the canopy-cruciform fixture design on the air pressure and flow distributions.
Air Quality Inside Police Drug Safes and Drug Storage Areas.
Doran, Gregory S; Deans, Ralph; De Filippis, Carlo; Kostakis, Chris; Howitt, Julia A
2018-06-01
Storage of drug-based evidence inside sealed safes may allow chemical vapors to accumulate, creating concerns of drug exposure by inhalation, or the possibility of cross-contamination of drug evidence. Air samples were taken from inside eight drug safes and one small storage room at nine city and country police stations, as well as a large centralized drug evidence storage vault, in New South Wales (NSW), Australia. Sorbent tubes containing charcoal were used to determine whether any drug residues could be detected in the air, and to identify the types of chemicals present. Carbon traps were extracted and analyzed by LC-MS-MS for a suite of 22 licit and illicit drug residues and 2 metabolites. Carbon traps and SPME fibers were also analyzed by GC-MS for general volatile organic compound (VOC) residues. No detectable drug residues, either as airborne dust or vapor, were found in the safes, the storage room or the large central repository vault. No drugs were detected in any of the 34 urine samples collected at 8 of the 10 sampling locations, while only one of the five hair samples was positive for cocaine (9 pg/mg) provided by police exhibit officers at 3 of the 10 sampling locations. VOC analysis identified a variety of solvents associated with drug manufacture, plasticisers, personal care products and volatiles associated with plants such as cannabis. The results indicate that strong chemical odours emanating from drug safes are unlikely to be drug residues due to low volatility of drugs, and are more likely VOCs associated with their manufacture or from plant growing operations. Consideration should be given to the quality of air flow in rooms in which safes are housed and the use of air filtering inside safes to reduce the likelihood of VOC accumulation, and therefore the risk of human exposure.
A novel web-enabled healthcare solution on health vault system.
Liao, Lingxia; Chen, Min; Rodrigues, Joel J P C; Lai, Xiaorong; Vuong, Son
2012-06-01
Complicated Electronic Medical Records (EMR) systems have created problems in systems regarding an easy implementation and interoperability for a Web-enabled Healthcare Solution, which is normally provided by an independent healthcare giver with limited IT knowledge and interests. An EMR system with well-designed and user-friendly interface, such as Microsoft HealthVault System used as the back-end platform of a Web-enabled healthcare application will be an approach to deal with these problems. This paper analyzes the patient oriented Web-enabled healthcare service application as the new trend to delivery healthcare from hospital/clinic-centric to patient-centric, the current e-healthcare applications, and the main backend EMR systems. Then, we present a novel web-enabled healthcare solution based on Microsoft HealthVault EMR system to meet customers' needs, such as, low total cost, easily development and maintenance, and good interoperability. A sample system is given to show how the solution can be fulfilled, evaluated, and validated. We expect that this paper will provide a deep understanding of the available EMR systems, leading to insights for new solutions and approaches driven to next generation EMR systems.
NASA Technical Reports Server (NTRS)
Le, Diana; Cooper, David M. (Technical Monitor)
1994-01-01
Just imagine a mass storage system that consists of a machine with 2 CPUs, 1 Gigabyte (GB) of memory, 400 GB of disk space, 16800 cartridge tapes in the automated tape silos, 88,000 tapes located in the vault, and the software to manage the system. This system is designed to be a data repository; it will always have disk space to store all the incoming data. Currently 9.14 GB of new data per day enters the system with this rate doubling each year. To assure there is always disk space available for new data, the system. has to move data reside from the expensive disk to a much less expensive medium such as the 3480 cartridge tapes. Once the data is archived to tape, it should be able to move back to disk when someone wants to access it and the data movement should be transparent to the user. Now imagine all the tasks that a system administrator must perform to keep this system running 24 hour a day, 7 days a week. Since the filesystem maintains the illusion of unlimited disk space, data that comes to the system must get moved to tapes in an efficient manner. This paper will describe the mass storage system running at the Numerical Aerodynamic Simulation (NAS) at NASA Ames Research Center in both software and hardware aspects, then it will describe all of the tasks the system administrator has to perform on this system.
Vault Area (original section), east corridor, Vault No. 5, showing ...
Vault Area (original section), east corridor, Vault No. 5, showing inner set of doors on vault - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC
The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation.
Qi, Meng-Ying; Chen, Qian; Zeng, Qing-Yan
2017-08-01
To identify associations between crystalline lens-related factors and central vault after Implantable Collamer Lens (ICL) (Staar Surgical, Monrovia, CA) implantation. This retrospective clinical study included 320 eyes from 186 patients who underwent ICL implantation surgery. At 1 year after surgery, the central vault was measured using anterior segment optical coherence tomography. Preoperative anterior chamber depth, lens thickness, lens position (lens position = anterior chamber depth + 1/2 lens thickness), and vault were analyzed to investigate the effects of lens-related factors on postoperative vault. The mean vault was 513 ± 215 µm at 1 year after surgery. Vault was positively correlated with preoperative anterior chamber depth (r = 0.495, P < .001) and lens position (r = 0.371, P < .001), but negatively correlated with lens thickness (r = -0.262, P < .001). Eyes with vaults of less than 250 µm had shallower anterior chambers, thicker lenses, and smaller lens position than eyes in the other two vault groups (which had vaults ≥ 250 µm) (P < .001). Eyes with both anterior chamber depth less than 3.1 mm and lens position less than 5.1 mm had greatly reduced vaults (P < .001). The crystalline lens could have an important influence on postoperative vault. Eyes with a shallower anterior chamber and a forward lens position will have lower vaults. [J Refract Surg. 2017;33(8):519-523.]. Copyright 2017, SLACK Incorporated.
71. Transmitter building no. 102, view of arrangement showing the ...
71. Transmitter building no. 102, view of arrangement showing the Klystron tube vaults along right side of photograph and capacitor vaults along left side of photograph. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
Eslick, Enid M; Keall, Paul J
2015-10-01
Rapid technological improvements in radiotherapy delivery results in improved outcomes to patients, yet current commercial systems with these technologies on board are costly. The aim of this study was to develop a state-of-the-art cancer radiotherapy system that is economical and space efficient fitting with current world demands. The Nano-X system is a compact design that is light weight combining a patient rotation system with a vertical 6 MV fixed beam. In this paper, we present the Nano-X system design configuration, an estimate of the system dimensions and its potential impact on shielding cost reductions. We provide an assessment of implementing such a radiotherapy system clinically, its advantages and disadvantages compared to a compact conventional gantry rotating linac. The Nano-X system has several differentiating features from current radiotherapy systems, it is [1] compact and therefore can fit into small vaults, [2] light weight, and [3] engineering efficient, i.e., it rotates a relatively light component and the main treatment delivery components are not under rotation (e.g., DMLCs). All these features can have an impact on reducing the costs of the system. In terms of shielding requirements, leakage radiation was found to be the dominant contributor to the Nano-X vault and as such no primary shielding was necessary. For a low leakage design, the Nano-X vault footprint and concrete volume required is 17 m2 and 35 m3 respectively, compared to 54 m2 and 102 m3 for a conventional compact linac vault, resulting in decreased costs in shielding. Key issues to be investigated in future work are the possible patient comfort concerns associated with the patient rotation system, as well as the magnitude of deformation and subsequent adaptation requirements. © The Author(s) 2014.
49 CFR 192.187 - Vaults: Sealing, venting, and ventilation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... vault or pit is sealed, each opening must have a tight fitting cover without open holes through which an... Components § 192.187 Vaults: Sealing, venting, and ventilation. Each underground vault or closed top pit....7 cubic meters): (1) The vault or pit must be ventilated with two ducts, each having at least the...
340 Facility secondary containment and leak detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bendixsen, R.B.
1995-01-31
This document presents a preliminary safety evaluation for the 340 Facility Secondary Containment and Leak Containment system, Project W-302. Project W-302 will construct Building 340-C which has been designed to replace the current 340 Building and vault tank system for collection of liquid wastes from the Pacific Northwest Laboratory buildings in the 300 Area. This new nuclear facility is Hazard Category 3. The vault tank and related monitoring and control equipment are Safety Class 2 with the remainder of the structure, systems and components as Safety Class 3 or 4.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Narlesky, Joshua Edward; Wilson, Kennard Virden Jr.; Kelly, Elizabeth J.
A microscopic examination was performed on a Hagan container after corrosion and a white powder were found on the outside surface of the lid and filter cover while in storage in the vault. The inside surfaces of the container were covered by a wipeable brown coating. The coating was removed and portions of the container were sectioned and imaged with optical microscopy. General corrosion was found throughout the inside of the container, and pitting corrosion was observed in several locations on the lid and sidewall. This report describes the type and extent of the corrosion observed and its impact onmore » the storage lifetime of the container.« less
Structural stability of vault particles.
Esfandiary, Reza; Kickhoefer, Valerie A; Rome, Leonard H; Joshi, Sangeeta B; Middaugh, C Russell
2009-04-01
Vaults, at 13 MDa, are the largest ribonucleoprotein particles known. In vitro, expression of the major vault protein (MVP) alone in Sf9 insect cells results in the production of recombinant particles with characteristic vault structure. With the ultimate goal of using recombinant vaults as nanocapsules for the delivery of biomolecules, we have employed a variety of spectroscopic techniques (i.e., circular dichroism, fluorescence spectroscopy, and light scattering) along with electron microscopy, to characterize the structural stability of vaults over a wide range of pH (3-8) and temperature (10-90 degrees C). Ten different conformational states of the vaults were identified over the pH and temperature range studied with the most stable region at pH 6-8 below 40 degrees C and least stable at pH 4-6 above 60 degrees C. A unique intermediate molten globulelike state was also identified at pH 6 and approximately 55 degrees C. EM imaging showed the opening of intact vaults into flowerlike structures when transitioning from neutral to acidic pH. This information has potential use in the development of recombinant vaults into nanocapsules for drug delivery since one mechanism by which therapeutic agents entrapped in vaults could be released is through an opening of the intact vault structure.
A spinner magnetometer for large Apollo lunar samples.
Uehara, M; Gattacceca, J; Quesnel, Y; Lepaulard, C; Lima, E A; Manfredi, M; Rochette, P
2017-10-01
We developed a spinner magnetometer to measure the natural remanent magnetization of large Apollo lunar rocks in the storage vault of the Lunar Sample Laboratory Facility (LSLF) of NASA. The magnetometer mainly consists of a commercially available three-axial fluxgate sensor and a hand-rotating sample table with an optical encoder recording the rotation angles. The distance between the sample and the sensor is adjustable according to the sample size and magnetization intensity. The sensor and the sample are placed in a two-layer mu-metal shield to measure the sample natural remanent magnetization. The magnetic signals are acquired together with the rotation angle to obtain stacking of the measured signals over multiple revolutions. The developed magnetometer has a sensitivity of 5 × 10 -7 Am 2 at the standard sensor-to-sample distance of 15 cm. This sensitivity is sufficient to measure the natural remanent magnetization of almost all the lunar basalt and breccia samples with mass above 10 g in the LSLF vault.
A spinner magnetometer for large Apollo lunar samples
NASA Astrophysics Data System (ADS)
Uehara, M.; Gattacceca, J.; Quesnel, Y.; Lepaulard, C.; Lima, E. A.; Manfredi, M.; Rochette, P.
2017-10-01
We developed a spinner magnetometer to measure the natural remanent magnetization of large Apollo lunar rocks in the storage vault of the Lunar Sample Laboratory Facility (LSLF) of NASA. The magnetometer mainly consists of a commercially available three-axial fluxgate sensor and a hand-rotating sample table with an optical encoder recording the rotation angles. The distance between the sample and the sensor is adjustable according to the sample size and magnetization intensity. The sensor and the sample are placed in a two-layer mu-metal shield to measure the sample natural remanent magnetization. The magnetic signals are acquired together with the rotation angle to obtain stacking of the measured signals over multiple revolutions. The developed magnetometer has a sensitivity of 5 × 10-7 Am2 at the standard sensor-to-sample distance of 15 cm. This sensitivity is sufficient to measure the natural remanent magnetization of almost all the lunar basalt and breccia samples with mass above 10 g in the LSLF vault.
Storage depot for radioactive material
Szulinski, Milton J.
1983-01-01
Vertical drilling of cylindrical holes in the soil, and the lining of such holes, provides storage vaults called caissons. A guarded depot is provided with a plurality of such caissons covered by shielded closures preventing radiation from penetrating through any linear gap to the atmosphere. The heat generated by the radioactive material is dissipated through the vertical liner of the well into the adjacent soil and thus to the ground surface so that most of the heat from the radioactive material is dissipated into the atmosphere in a manner involving no significant amount of biologically harmful radiation. The passive cooling of the radioactive material without reliance upon pumps, personnel, or other factor which might fail, constitutes one of the most advantageous features of this system. Moreover this system is resistant to damage from tornadoes or earthquakes. Hermetically sealed containers of radioactive material may be positioned in the caissons. Loading vehicles can travel throughout the depot to permit great flexibility of loading and unloading radioactive materials. Radioactive material can be shifted to a more closely spaced caisson after ageing sufficiently to generate much less heat. The quantity of material stored in a caisson is restricted by the average capacity for heat dissipation of the soil adjacent such caisson.
Seismic Behaviour of Masonry Vault-Slab Structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chesi, Claudio; Butti, Ferdinando; Ferrari, Marco
2008-07-08
Spandrel walls typically play a structural role in masonry buildings, transferring load from a slab to the supporting vault. Some indications are given in the literature on the behaviour of spandrels under the effect of vertical loads, but little attention is given to the effect coming from lateral forces acting on the building. An opportunity to investigate this problem has come from the need of analyzing a monumental building which was damaged by the Nov. 24, 2004 Val Sabbia earthquake in the north of Italy. The finite element model set up for the analysis of the vault-spandrel-slab system is presentedmore » and the structural role resulting for the spandrels is discussed.« less
Rupture loop annex ion exchange RLAIX vault deactivation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ham, J.E.; Harris, D.L., Westinghouse Hanford
This engineering report documents the deactivation, stabilization and final conditions of the Rupture Loop Annex Ion Exchange (RLAIX) Vault located northwest of the 309 Building`s Plutonium Recycle Test Reactor (PRTR). Twelve ion exchange columns, piping debris, and column liquid were removed from the vault, packaged and shipped for disposal. The vault walls and floor were decontaminated, and portions of the vault were painted to fix loose contamination. Process piping and drains were plugged, and the cover blocks and rain cover were installed. Upon closure,the vault was empty, stabilized, isolated.
Vault Area (original section), east corridor, looking north (Vault Nos. ...
Vault Area (original section), east corridor, looking north (Vault Nos. 1-9 - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC
Vault Area (original section), east corridor, interior of Vault No. ...
Vault Area (original section), east corridor, interior of Vault No. 7, view west - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC
Vault Area (original section), east corridor, interior of Vault No. ...
Vault Area (original section), east corridor, interior of Vault No. 7, looking up flue - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC
Vault Area (original section), east corridor, Vault No. 3 showing ...
Vault Area (original section), east corridor, Vault No. 3 showing inside surface of outer door - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC
NASA Astrophysics Data System (ADS)
Benedict, K. K.; Servilla, M. S.; Vanderbilt, K.; Wheeler, J.
2015-12-01
The growing volume, variety and velocity of production of Earth science data magnifies the impact of inefficiencies in data acquisition, processing, analysis, and sharing workflows, potentially to the point of impairing the ability of researchers to accomplish their desired scientific objectives. The adaptation of agile software development principles (http://agilemanifesto.org/principles.html) to data curation processes has significant potential to lower barriers to effective scientific data discovery and reuse - barriers that otherwise may force the development of new data to replace existing but unusable data, or require substantial effort to make data usable in new research contexts. This paper outlines a data curation process that was developed at the University of New Mexico that provides a cross-walk of data and associated documentation between the data archive developed by the Long Term Ecological Research (LTER) Network Office (PASTA - http://lno.lternet.edu/content/network-information-system) and UNM's institutional repository (LoboVault - http://repository.unm.edu). The developed automated workflow enables the replication of versioned data objects and their associated standards-based metadata between the LTER system and LoboVault - providing long-term preservation for those data/metadata packages within LoboVault while maintaining the value-added services that the PASTA platform provides. The relative ease with which this workflow was developed is a product of the capabilities independently developed on both platforms - including the simplicity of providing a well-documented application programming interface (API) for each platform enabling scripted interaction and the use of well-established documentation standards (EML in the case of PASTA, Dublin Core in the case of LoboVault) by both systems. These system characteristics, when combined with an iterative process of interaction between the Data Curation Librarian (on the LoboVault side of the process), the Sevilleta LTER Information Manager and the LTER Network Information System developer, yielded a rapid and relatively streamlined process for targeted replication of data and metadata between the two systems - increasing the discoverability and usability of the LTER data assets.
Type B investigation of electrical fault in 351 Substation, December 4, 1994
DOE Office of Scientific and Technical Information (OSTI.GOV)
Debban, H.L.; Shearer, C.A.; Boger, R.M.
1995-02-01
On December 4, 1994, at 2132:10 hours, an electrical failure of a cable-tapping splice resulted in a fire in the 300 Area of the DOE Hanford Site. The fire occurred in the yard of Substation 351 in electrical Vault R122V, where the cable-tapping splice was located. The fire incinerated all cables passing to and through the vault causing them to fail. The failure of the cables resulted in a power outage to twenty customers in the 300 Area. The vault was electrically isolated, and power was restored to the electrical distribution system at 2311 hours. This report contains the accidentmore » scenario, accident analysis, direct cause and root and contributing causes.« less
Malinowski, Andrzej; Mołas, Justyna; Maciołek-Blewniewska, Grazyna; Cieślak, Jarosław
2006-02-01
Vault haematoma is one of the most common complication of vaginal hysterectomy. The aim of this work was to analyse the effects of a modification of incision and closure technique of the vaginal vault on the incidence of vault haematoma after vaginal hysterectomy. The study group consisted of 333 women of whom 49 (group A) underwent vaginal hysterectomy traditional technique of incision and closure of the vaginal vault, an 284 (group B) modified technique. Following parameters were evaluated: number of vault haematomas, blood loss, postoperative fever, required antibiotics, length of hospital stay. The risk of vault haematoma was significantly lower in the group B (1,06% vs 12,4%). Loss of blood was higher in group A (310 ml vs 206 ml). Incidence of postoperative fever was in 12,2% patients from group A, and 1,4% from group B. The length of hospitalization was lower for women in group B (4,3 days compared with 7,3 days). The modification of incision and closure technique of the vaginal vault during vaginal hysterectomy is recommended to minimise intra- and postoperative complications.
1983-12-01
STATEMN’T L * N N 0UNCE D J UST I IICATION T DI Sr 141I IIIT ION / AVAII.ABII flV CODES )SFRIKB-T.OS AVAr.Aa[Ll-Y ANOi SPECIAL ePI A /DIST RIUTION STAMP...Storage Area No. 3 I C-3 Analytical Results for the Soil Sample Taken in the North Parking Lot APPENDIX D PHOTiOGRAPiS APPENDIX E USAF INSTALLATION...1970’s-1981 54 Storage No. 4 5 Underground Cyanide Mid 1950’s to La te 1970’s 51 I Vault i I 1 I I I FIGURE 1 00 z IWO zZi II : 0C OJ IL W z D 0j I co
Vault Nanoparticles Packaged with Enzymes as an Efficient Pollutant Biodegradation Technology.
Wang, Meng; Abad, Danny; Kickhoefer, Valerie A; Rome, Leonard H; Mahendra, Shaily
2015-11-24
Vault nanoparticles packaged with enzymes were synthesized as agents for efficiently degrading environmental contaminants. Enzymatic biodegradation is an attractive technology for in situ cleanup of contaminated environments because enzyme-catalyzed reactions are not constrained by nutrient requirements for microbial growth and often have higher biodegradation rates. However, the limited stability of extracellular enzymes remains a major challenge for practical applications. Encapsulation is a recognized method to enhance enzymatic stability, but it can increase substrate diffusion resistance, lower catalytic rates, and increase the apparent half-saturation constants. Here, we report an effective approach for boosting enzymatic stability by single-step packaging into vault nanoparticles. With hollow core structures, assembled vault nanoparticles can simultaneously contain multiple enzymes. Manganese peroxidase (MnP), which is widely used in biodegradation of organic contaminants, was chosen as a model enzyme in the present study. MnP was incorporated into vaults via fusion to a packaging domain called INT, which strongly interacts with vaults' interior surface. MnP fused to INT and vaults packaged with the MnP-INT fusion protein maintained peroxidase activity. Furthermore, MnP-INT packaged in vaults displayed stability significantly higher than that of free MnP-INT, with slightly increased Km value. Additionally, vault-packaged MnP-INT exhibited 3 times higher phenol biodegradation in 24 h than did unpackaged MnP-INT. These results indicate that the packaging of MnP enzymes in vault nanoparticles extends their stability without compromising catalytic activity. This research will serve as the foundation for the development of efficient and sustainable vault-based bioremediation approaches for removing multiple contaminants from drinking water and groundwater.
Movement Regulation of Handsprings on Vault
ERIC Educational Resources Information Center
Heinen, Thomas; Vinken, Pia M.; Jeraj, Damian; Velentzas, Konstantinos
2013-01-01
Purpose: Visual information is utilized in gymnastics vaulting. The question remains as to which informational sources are used to regulate handspring performance. The purpose of this study was to examine springboard and vaulting table position as informational sources in gymnastics vaulting. The hypothesis tested was that the approach-run and…
Structure of the vault, a ubiquitous celular component.
Kong, L B; Siva, A C; Rome, L H; Stewart, P L
1999-04-15
The vault is a ubiquitous and highly conserved ribonucleoprotein particle of approximately 13 MDa. This particle has been shown to be upregulated in certain multidrug-resistant cancer cell lines and to share a protein component with the telomerase complex. Determination of the structure of the vault was undertaken to provide a first step towards understanding the role of this cellular component in normal metabolism and perhaps to shed some light on its role in mediating drug resistance. Over 1300 particle images were combined to calculate an approximately 31 A resolution structure of the vault. Rotational power spectra did not yield a clear symmetry peak, either because of the thin, smooth walls or inherent flexibility of the vault. Although cyclic eightfold (C8) symmetry was imposed, the resulting reconstruction may be partially cylindrically averaged about the eightfold axis. Our results reveal the vault to be a hollow, barrel-like structure with two protruding caps and an invaginated waist. Although the normal cellular function of the vault is as yet undetermined, the structure of the vault is consistent with either a role in subcellular transport, as previously suggested, or in sequestering macromolecular assemblies.
Determinants of lens vault and association with narrow angles in patients from Singapore.
Tan, Gavin S; He, Mingguang; Zhao, Wanting; Sakata, Lisandro M; Li, Jialiang; Nongpiur, Monisha E; Lavanya, Raghavan; Friedman, David S; Aung, Tin
2012-07-01
To describe the distribution and determinants of lens vault and to investigate the association of lens vault with narrow angles. Prospective cross-sectional study. Phakic subjects 50 years and older were evaluated at a primary healthcare clinic with gonioscopy, partial laser interferometry, and anterior segment optical coherence tomography (AS-OCT). Narrow angles were defined as posterior trabecular meshwork not visible for ≥2 quadrants on non-indentation gonioscopy. Lens vault was defined as the perpendicular distance between the anterior pole of the crystalline lens and the horizontal line joining the 2 scleral spurs on horizontal AS-OCT scans. Analysis of covariance, multivariate logistic regression, and area under the receiver operating characteristic curves (AUC) were performed. Of the 2047 subjects recruited, 582 were excluded because of poor image quality or inability to locate scleral spurs, leaving 1465 subjects for analysis. Eyes with narrow angles had greater lens vault compared to eyes with open angles (775.6 µm vs 386.5 µm, P < .0001). Women had significantly greater lens vault than men (497.28 µm vs 438.56 µm, P < .001), and lens vault increased significantly with age (P for trend <.001). Adjusted for age and sex, significant associations with greater lens vault were shorter axial length, shallower anterior chamber depth(ACD), higher intraocular pressure, and more hyperopic spherical equivalent (all P < .001). On multivariate analysis, subjects with lens vault >667.6 µm were more likely to have narrow angles (OR 2.201, 95% CI: 1.070-4.526) compared to those with lens vault ≤462.7 µm. The AUC for lens vault (0.816) and ACD (0.822) for detecting narrow angles were similar (P = .582). Lens vault was independently associated with narrow angles and may be useful in screening to detect eyes with narrow angles. Copyright © 2012 Elsevier Inc. All rights reserved.
Calculation of the nuclear material inventory in a sealed vault by 3D radiation mapping
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adsley, Ian; Klepikov, Alexander; Tur, Yevgeniy
2013-07-01
The paper relates to the determination of the amount of nuclear material contained in a closed, concrete lined vault at the Aktau fast breeder reactor in Kazakhstan. This material had been disposed into the vault after examination in an experimental hot cell directly above the vault. In order to comply with IAEA Safeguards requirements it was necessary to determine the total quantities of nuclear materials - enriched uranium and plutonium - that were held with Kazakhstan. Although it was possible to determine the inventory of all of the accessible nuclear material - the quantity remaining in the vault was unknown.more » As part of the Global Threat Reduction Programme the UK Government funded a project to determine the inventory of these nuclear materials in this vault. This involved drilling three penetrations through the concrete lined roof of the vault; this enabled the placement of lights and a camera into the vault through two penetrations; while the third penetration enabled a lightweight manipulator arm to be introduced into the vault. This was used to provide a detailed 3D mapping of the dose rate within the vault and it also enabled the collection of samples for radionuclide analysis. The deconvolution of the 3D dose rate profile within the vault enabled the determination of the gamma emitting source distribution on the floor and walls of the vault. The samples were analysed to determine the fingerprint of those radionuclides producing the gamma dose - namely {sup 137}Cs and {sup 60}Co - to the nuclear materials. The combination of the dose rate source terms on the surfaces of the vault and the fingerprint then enabled the quantities of nuclear materials to be determined. The project was a major success and enabled the Kazakhstan Government to comply with IAEA Safeguards requirements. It also enabled the UK DECC Ministry to develop a technology of national (and international) use. Finally the technology was well received by IAEA Safeguards as an acceptable methodology for future studies. (authors)« less
Comparative Noise Performance of Portable Broadband Sensor Emplacements
NASA Astrophysics Data System (ADS)
Sweet, Justin; Arias-Dotson, Eliana; Beaudoin, Bruce; Anderson, Kent
2015-04-01
IRIS PASSCAL has supported portable broadband seismic experiments for close to 30 years. During that time we have seen a variety of sensor vaults deployed. The vaults deployed fall into two broad categories, a PASSCAL style vault and a Flexible Array style vault. The PASSCAL vault is constructed of materials available in-county and it is the Principle Investigator (PI) who establishes the actual field deployed design. These vaults generally are a large barrel placed in a ~1 m deep hole. A small pier, decoupled from the barrel, is fashioned in the bottom of the vault (either cement, paving stone or tile) for the sensor placement. The sensor is insulated and protected. Finally the vault is sealed and buried under ~30 cm of soil. The Flexible Array vault is provided to PIs by the EarthScope program, offering a uniform portable vault for these deployments. The vault consists of a 30 cm diameter by 0.75 cm tall piece of plastic sewage pipe buried with ~10 cm of pipe above grade. A rubber membrane covers the bottom and cement was poured into the bottom, coupling the pier to the pipe. The vault is sealed and buried under ~30 cm of soil. Cost, logistics, and the availability of materials in-country are usually the deciding factors for PIs when choosing a vault design and frequently trades are made given available resources. Recently a third type of portable broadband installation, direct burial, is being tested. In this case a sensor designed for shallow, direct burial is installed in a ~20 cm diameter by ~1 m deep posthole. Direct burial installation costs are limited to the time and effort required to dig the posthole and emplace the sensor. Our initial analyses suggest that direct burial sensors perform as well and at times better than sensor in vaults on both horizontal and vertical channels across a range of periods (<1 s to 100 s). Moving towards an instrument pool composed entirely of direct burial sensors (some with integrated digitizers) could yield higher-quality data at lower cost. Until recently vault performance for portable installations supported by the PASSCAL program was anecdotal. A formal comparison of these various installation techniques is the subject of this poster. We've selected a suite of experiments that are representative of the three installation techniques and compare their noise performance by using PSD probability density functions (McNamara and Buland, 2004).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guyer, H.B.; McChesney, C.A.
The overall primary Objective of HDAR is to create a repository of historical personnel security documents and provide the functionality needed for archival and retrieval use by other software modules and application users of the DISS/ET system. The software product to be produced from this specification is the Historical Document Archival and Retrieval Subsystem The product will provide the functionality to capture, retrieve and manage documents currently contained in the personnel security folders in DOE Operations Offices vaults at various locations across the United States. The long-term plan for DISS/ET includes the requirement to allow for capture and storage ofmore » arbitrary, currently undefined, clearance-related documents that fall outside the scope of the ``cradle-to-grave`` electronic processing provided by DISS/ET. However, this requirement is not within the scope of the requirements specified in this document.« less
Shape and Construction of Brick Vaults. Criteria, Methods and Tools for a Possible Catalogue
NASA Astrophysics Data System (ADS)
Brumana, R.; Condoleo, P.; Grimoldi, A.; Landi, A. G.
2017-05-01
The use of cloister vaults in the construction of noble buildings, as covering elements for square or rectangular rooms, is widespread and well-known. The geometric continuity at the intrados makes generally possible the execution all over the span of frescoes, stucco and decorations. The construction of brick vaults, from the late Middle Age, was sped up by limiting the centering to the wooden planks arches that were instrumental in the profile determination. Nowadays, the availability of several procedures, phases and tools for carrying out a survey allows to draw reliable assumptions about the construction methods and the execution time. It is mandatory to determine the properties of the binders, the shape and dimensions of the bricks, and to carry out a comparison between the geometry of the intrados surface and the evidences emerging at the extrados. The support of the laser scanner technique allows to accurately identify the surface profile and thickness. All these indications, in turn, are useful, in view of an interpretation of the structural behavior, to identify weaknesses, and to highlight contributing factors of instability (if any). The paper focuses on a well-documented case, the Magio Grasselli palace in Cremona in which the cloister vaults of two main rooms show different construction systems, although they were built almost at the same time. The thermographic recordings and laser-scanner surveys highlight the various arrangements used for the cloister vaults.
Reliability and variability of day-to-day vault training measures in artistic gymnastics.
Bradshaw, Elizabeth; Hume, Patria; Calton, Mark; Aisbett, Brad
2010-06-01
Inter-day training reliability and variability in artistic gymnastics vaulting was determined using a customised infra-red timing gate and contact mat timing system. Thirteen Australian high performance gymnasts (eight males and five females) aged 11-23 years were assessed during two consecutive days of normal training. Each gymnast completed a number of vault repetitions per daily session. Inter-day variability of vault run-up velocities (at -18 to -12 m, -12 to -6 m, -6 to -2 m, and -2 to 0 m from the nearest edge of the beat board), and board contact, pre-flight, and table contact times were determined using mixed modelling statistics to account for random (within-subject variability) and fixed effects (gender, number of subjects, number of trials). The difference in the mean (Mdiff) and Cohen's effect sizes for reliability assessment and intra-class correlation coefficients, and the coefficient of variation percentage (CV%) were calculated for variability assessment. Approach velocity (-18 to -2m, CV = 2.4-7.8%) and board contact time (CV = 3.5%) were less variable measures when accounting for day-to-day performance differences, than pre-flight time (CV = 17.7%) and table contact time (CV = 20.5%). While pre-flight and table contact times are relevant training measures, approach velocity and board contact time are more reliable when quantifying vaulting performance.
A Hybrid Approach to Protect Palmprint Templates
Sun, Dongmei; Xiong, Ke; Qiu, Zhengding
2014-01-01
Biometric template protection is indispensable to protect personal privacy in large-scale deployment of biometric systems. Accuracy, changeability, and security are three critical requirements for template protection algorithms. However, existing template protection algorithms cannot satisfy all these requirements well. In this paper, we propose a hybrid approach that combines random projection and fuzzy vault to improve the performances at these three points. Heterogeneous space is designed for combining random projection and fuzzy vault properly in the hybrid scheme. New chaff point generation method is also proposed to enhance the security of the heterogeneous vault. Theoretical analyses of proposed hybrid approach in terms of accuracy, changeability, and security are given in this paper. Palmprint database based experimental results well support the theoretical analyses and demonstrate the effectiveness of proposed hybrid approach. PMID:24982977
A hybrid approach to protect palmprint templates.
Liu, Hailun; Sun, Dongmei; Xiong, Ke; Qiu, Zhengding
2014-01-01
Biometric template protection is indispensable to protect personal privacy in large-scale deployment of biometric systems. Accuracy, changeability, and security are three critical requirements for template protection algorithms. However, existing template protection algorithms cannot satisfy all these requirements well. In this paper, we propose a hybrid approach that combines random projection and fuzzy vault to improve the performances at these three points. Heterogeneous space is designed for combining random projection and fuzzy vault properly in the hybrid scheme. New chaff point generation method is also proposed to enhance the security of the heterogeneous vault. Theoretical analyses of proposed hybrid approach in terms of accuracy, changeability, and security are given in this paper. Palmprint database based experimental results well support the theoretical analyses and demonstrate the effectiveness of proposed hybrid approach.
Speiser, M; Hager, F; Foster, R; Solberg, T
2012-06-01
To design and quantify the shielding efficacy of an inner Borated Polyethylene (BPE)wall for a 15 MV linac in a low energy vault. A Varian TrueBeam linac with a maximum photon energy of 15 MV was installed in asmaller, preexisting vault. This vault originally housed a low-energy machine and did not havesufficient maze length recommended for neutron attenuation. Effective dose rate calculationswere performed using the Modified Kersey's Method as detailed in NCRP Report No. 151 andfound to be unacceptably high. An initial survey following the machine installation confirmedthese calculations. Rather than restrict the linac beam energy to 10 MV, BPE was investigatedas a neutron moderating addition. An inner wall and door were planned and constructed using4'×8'×1″ thick 5% BPE sheets. The resulting door and wall had 2″ of BPE; conduits and ductwork were also redesigned and shielded. A survey was conducted following construction of thewall. The vault modification reduced the expected effective dose at the vault door from 36.23to 0.010 mSv/week. As specific guidelines for vault modification are lacking, this project quantitativelydemonstrates the potential use of BPE for vault modification. Such modifications may provide alow-cost shielding solution to allow for the use of high energy modes in smaller treatment vaults. © 2012 American Association of Physicists in Medicine.
Dynamic research of masonry vault in a technical scale
NASA Astrophysics Data System (ADS)
Golebiewski, Michal; Lubowiecka, Izabela; Kujawa, Marcin
2017-03-01
The paper presents preliminary results of dynamic tests of the masonry barrel vault in a technical scale. Experimental studies are intended to identify material properties of homogenized masonry vaults under dynamic loads. The aim of the work is to create numerical models to analyse vault's dynamic response to dynamic loads in a simplest and accurate way. The process of building the vault in a technical scale is presented in the paper. Furthermore a excitation of vibrations with an electrodynamic modal exciter placed on the vault, controlled by an arbitrary waveform function generator, is discussed. Finally paper presents trends in the research for homogenization algorithm enabling dynamic analysis of masonry vaults. Experimental results were compared with outcomes of so-called macromodels (macromodel of a brick masonry is a model in which masonry, i.e. a medium consisting of two different fractions - bricks and mortar, is represented by a homogenized, uniformed, material). Homogenization entail significant simplifications, nevertheless according to the authors, can be a useful approach in a static and dynamic analysis of masonry structures.
Derivation of the mammalian skull vault
MORRISS-KAY, GILLIAN M.
2001-01-01
This review describes the evolutionary history of the mammalian skull vault as a basis for understanding its complex structure. Current information on the developmental tissue origins of the skull vault bones (mesoderm and neural crest) is assessed for mammals and other tetrapods. This information is discussed in the context of evolutionary changes in the proportions of the skull vault bones at the sarcopterygian-tetrapod transition. The dual tissue origin of the skull vault is considered in relation to the molecular mechanisms underlying osteogenic cell proliferation and differentiation in the sutural growth centres and in the proportionate contributions of different sutures to skull growth. PMID:11523816
2010-07-12
Technicians lowered a special radiation vault onto the propulsion module of NASA Juno spacecraft. The vault will dramatically slow the aging effect radiation has on the electronics for the duration of the mission.
2. VIEW, LOOKING NORTHWEST, FROM INSIDE THE PROTECTED AREA AT ...
2. VIEW, LOOKING NORTHWEST, FROM INSIDE THE PROTECTED AREA AT THE BASE OF TOWER 901. THE BUILDINGS IN THE FOREGROUND INCLUDE 984, 992, 991, 989, AND 968. THESE BUILDINGS MAKE UP THE BUILDING 991 COMPLEX. BUILDING 991, PLANT D, WAS THE FIRST OPERATIONAL BUILDING ON SITE, CONSTRUCTED IN 1951 AS THE FINAL ASSEMBLY AND SHIPPING AND RECEIVING BUILDING. TO THE NORTH AND NORTHWEST OF BUILDING 991 ARE THE UNDERGROUND VAULTS AND TUNNELS USED TO STORAGE WEAPONS COMPONENTS. - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO
1. VIEW OF THE CONTROL ROOM FOR THE XY RETRIEVER. ...
1. VIEW OF THE CONTROL ROOM FOR THE X-Y RETRIEVER. USING THE X-Y RETRIEVER, OPERATORS RETRIEVED PLUTONIUM METAL FROM THE PLUTONIUM STORAGE VAULTS (IN MODULE K) AND CONVEYED IT TO THE X-Y SHUTTLE AREA WHERE IT WAS CUT AND WEIGHED. FROM THE SHUTTLE AREA THE PLUTONIUM WAS CONVEYED TO MODULES A, J OR K FOR CASTING, OR MODULE B FOR ROLLING AND FORMING. (5/17/71) - Rocky Flats Plant, Plutonium Manufacturing Facility, North-central section of Plant, just south of Building 776/777, Golden, Jefferson County, CO
E-Area Vault Concrete Material Property And Vault Durability/Degradation Projection Recommendations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phifer, M. A.
2014-03-11
Subsequent to the 2008 E-Area Low-Level Waste Facility (ELLWF) Performance Assessment (PA) (WSRC 2008), two additional E-Area vault concrete property testing programs have been conducted (Dixon and Phifer 2010 and SIMCO 2011a) and two additional E-Area vault concrete durability modeling projections have been made (Langton 2009 and SIMCO 2012). All the information/data from these reports has been evaluated and consolidated herein by the Savannah River National Laboratory (SRNL) at the request of Solid Waste Management (SWM) to produce E-Area vault concrete hydraulic and physical property data and vault durability/degradation projection recommendations that are adequately justified for use within associated Specialmore » Analyses (SAs) and future PA updates. The Low Activity Waste (LAW) and Intermediate Level (IL) Vaults structural degradation predictions produced by Carey 2006 and Peregoy 2006, respectively, which were used as the basis for the 2008 ELLWF PA, remain valid based upon the results of the E-Area vault concrete durability simulations reported by Langton 2009 and those reported by SIMCO 2012. Therefore revised structural degradation predictions are not required so long as the mean thickness of the closure cap overlying the vaults is no greater than that assumed within Carey 2006 and Peregoy 2006. For the LAW Vault structural degradation prediction (Carey 2006), the mean thickness of the overlying closure cap was taken as nine feet. For the IL Vault structural degradation prediction (Peregoy 2006), the mean thickness of the overlying closure cap was taken as eight feet. The mean closure cap thicknesses as described here for both E-Area Vaults will be included as a key input and assumption (I&A) in the next revision to the closure plan for the ELLWF (Phifer et al. 2009). In addition, it has been identified as new input to the PA model to be assessed in the ongoing update to the new PA Information UDQE (Flach 2013). Once the UDQE is approved, the SWM Key I&A database will be updated with this new information.« less
Choi, Ki Hwan; Chung, Song Ee; Chung, Tae Young; Chung, Eui Sang
2007-04-01
To assess the efficacy of the ultrasound biomicroscopic (UBM) method in estimating the sulcus-to-sulcus horizontal diameter for Visian Implantable Contact Lens (ICL, model V4) length determination to obtain optimal ICL vault. The results of postoperative ICL vaults in 30 eyes of 18 patients were retrospectively analyzed. In 17 eyes, ICL length was determined using the conventional method, and in 13 eyes, ICL length was determined using the UBM method. The UBM method was carried out by measuring the sulcus to limbus distance on each side by 50 MHz UBM and adding the white-to-white diameter by caliper or Orbscan. The ICL vaults were measured using the UBM method at 1 and 6 months postoperatively and the results were compared between the two groups. Ideal ICL vault was defined as vault between 250 and 750 microm. The relation between the ICL vault, footplate location, and ICL power was also investigated. In the UBM method group, ICL vault was within the ideal range in all 13 (100%) eyes at 1 and 6 months postoperatively, whereas in the conventional method group, 10 (58.8%) eyes showed ideal vault at 1 month postoperatively (P = .01) and 9 (52.9%) eyes showed ideal vault at 6 months postoperatively (P < .01). The ideal ICL footplate location was achieved in the ciliary sulcus in 11 (84.6%) eyes of the UBM method group and 10 (64.7%) eyes of the conventional method group. However, the differences between the two groups were not statistically significant. The ICL vault was not significantly affected by the ICL power. Implantable Contact Lens length determined by the UBM method achieved significantly more ideal ICL vault than that of the conventional white-to-white method. The UBM method is superior to the conventional method in terms of predicting the sulcus-to-sulcus horizontal diameter for ICL length determination.
Inspecting Juno Radiation Vault
2010-07-12
A technician inspects the special radiation vault being installed atop the propulsion module of NASA Juno spacecraft; the vault has titanium walls to protect the spacecraft electronic brain and heart from Jupiter harsh radiation environment.
Radiation shielding design of a new tomotherapy facility.
Zacarias, Albert; Balog, John; Mills, Michael
2006-10-01
It is expected that intensity modulated radiation therapy (IMRT) and image guided radiation therapy (IGRT) will replace a large portion of radiation therapy treatments currently performed with conventional MLC-based 3D conformal techniques. IGRT may become the standard of treatment in the future for prostate and head and neck cancer. Many established facilities may convert existing vaults to perform this treatment method using new or upgraded equipment. In the future, more facilities undoubtedly will be considering de novo designs for their treatment vaults. A reevaluation of the design principles used in conventional vault design is of benefit to those considering this approach with a new tomotherapy facility. This is made more imperative as the design of the TomoTherapy system is unique in several aspects and does not fit well into the formalism of NCRP 49 for a conventional linear accelerator.
Experimental Analysis of Dynamic Effects of FRP Reinforced Masonry Vaults.
Corradi, Marco; Borri, Antonio; Castori, Giulio; Coventry, Kathryn
2015-11-27
An increasing interest in the preservation of historic structures has produced a need for new methods for reinforcing curved masonry structures, such as arches and vaults. These structures are generally very ancient, have geometries and materials which are poorly defined and have been exposed to long-term historical movements and actions. Consequently, they are often in need of repair or reinforcement. This article presents the results of an experimental study carried out in the laboratory and during on-site testing to investigate the behaviour of brick masonry vaults under dynamic loading strengthened with FRPs (Fiber Reinforced Polymers). For the laboratory tests, the brick vaults were built with solid sanded clay bricks and weak mortar and were tested under dynamic loading. The experimental tests were designed to facilitate analysis of the dynamic behaviour of undamaged, damaged and reinforced vaulted structures. On-site tests were carried out on an earthquake-damaged thin brick vault of an 18th century aristocratic residence in the city of L'Aquila, Italy. The provision of FRP reinforcement is shown to re-establish elastic behavior previously compromised by time induced damage in the vaults.
Experimental Analysis of Dynamic Effects of FRP Reinforced Masonry Vaults
Corradi, Marco; Borri, Antonio; Castori, Giulio; Coventry, Kathryn
2015-01-01
An increasing interest in the preservation of historic structures has produced a need for new methods for reinforcing curved masonry structures, such as arches and vaults. These structures are generally very ancient, have geometries and materials which are poorly defined and have been exposed to long-term historical movements and actions. Consequently, they are often in need of repair or reinforcement. This article presents the results of an experimental study carried out in the laboratory and during on-site testing to investigate the behaviour of brick masonry vaults under dynamic loading strengthened with FRPs (Fiber Reinforced Polymers). For the laboratory tests, the brick vaults were built with solid sanded clay bricks and weak mortar and were tested under dynamic loading. The experimental tests were designed to facilitate analysis of the dynamic behaviour of undamaged, damaged and reinforced vaulted structures. On-site tests were carried out on an earthquake-damaged thin brick vault of an 18th century aristocratic residence in the city of L’Aquila, Italy. The provision of FRP reinforcement is shown to re-establish elastic behavior previously compromised by time induced damage in the vaults. PMID:28793697
Evaluation of the long-term performance of six alternative disposal methods for LLRW
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kossik, R.; Sharp, G.; Chau, T.
1995-12-31
The State of New York has carried out a comparison of six alternative disposal methods for low-level radioactive waste (LLRW). An important part of these evaluations involved quantitatively analyzing the long-term (10,000 yr) performance of the methods with respect to dose to humans, radionuclide concentrations in the environment, and cumulative release from the facility. Four near-surface methods (covered above-grade vault, uncovered above-grade vault, below-grade vault, augered holes) and two mine methods (vertical shaft mine and drift mine) were evaluated. Each method was analyzed for several generic site conditions applicable for the state. The evaluations were carried out using RIP (Repositorymore » Integration Program), an integrated, total system performance assessment computer code which has been applied to radioactive waste disposal facilities both in the U.S. (Yucca Mountain, WIPP) and worldwide. The evaluations indicate that mines in intact low-permeability rock and near-surface facilities with engineered covers generally have a high potential to perform well (within regulatory limits). Uncovered above-grade vaults and mines in highly fractured crystalline rock, however, have a high potential to perform poorly, exceeding regulatory limits.« less
SIIOS in Alaska - Testing an `In-Vault' Option for a Europa Lander Seismometer.
NASA Astrophysics Data System (ADS)
Bray, V. J.; Weber, R. C.; DellaGiustina, D. N.; Bailey, H.; Schmerr, N. C.; Pettit, E. C.; Dahl, P.; Albert, D.; Avenson, B.; Byrne, S.; Siegler, M.; Bland, M. T.; Patterson, G. W.; Selznick, S.
2017-12-01
The surface environment of Europa within the radiation-heavy jovian system, poses extreme technical challenges for potential landed missions. The need for radiation shielding and protection from the cold requires instruments to be housed within a thermally insulated and radiation protected `vault'. Unfortunately, this is non-ideal for seismometers as instrument-to-surface coupling is an important factor in the quality of returned data. Delivering a seismic package to an icy world would therefore benefit from the development of a cold-tolerant, radiation-hardened sensor that can survive outside of a protective vault. If such an instrument package were not technologically mature enough, or if lander safety considerations prevent deployment on lander legs, an in-vault location is still a viable option. For such a case, a better understanding of the transmission of seismic signals received through the lander legs is necessary for interpretation of the received signals. The performance, mass, and volume of the `Seismometer to investigate ice and ocean structure' (SIIOS) already meet or exceed flight requirements identified in lander studies for the icy moon Europa. We are testing this flight-candidate in several configurations around and within a lander mock-up, assuming a 1x1 meter vault with extended legs. We compare the received signals from a SIIOS device on the ice with those received by an identical sensor directly above it in the `vault'. We also compare the data from these single-point receivers to that received by two short base-line arrays - A 4-point "in-vault" array and another 4-point array arranged at the ice surface at the base of the lander legs. Our field-testing is performed at Gulkana Glacier, Alaska. The summer melt season provides kilometer-scale regions of coexisting ice, water, and silicate material, thereby providing seismic contrasts analogous to the ice-water layers and possible sub-surface lakes expected at Europa. We demonstrate the sensitivity of SIIOS to detect a variety of passive and active sources from both on-ice and lander-mounted locations, and compare the accuracy of ice-water boundary identification and event location from each configuration.
D Surveying and Geometric Assessment of a Gothic Nave Vaulting from Point Clouds
NASA Astrophysics Data System (ADS)
Costa-Jover, A.; Ginovart, J. Lluis i.; Coll-Pla, S.; López Piquer, M.; Samper-Sosa, A.; Moreno García, D.; Solís Lorenzo, A. M.
2017-02-01
The development of massive data captures techniques (MDC) in recent years, such as the Terrestrial laser Scanner (TLS), raises the possibility of developing new assessment procedures for architectural heritage. The 3D models that it is able to obtain is a great potential tool, both for conservation purposes and for historical and architectural studies. The paper proposes a simple, non-invasive methodology for the assessment of masonry vaults from point clouds which makes it possible to obtain relevant data about the formal anomalies. The methodology is tested in Tortosa's Gothic Cathedral's vaults, where the geometrical differences between vaults, a priori equal, are identified and related with the partially known construction phases. The procedure can be easily used on any other vaulted construction of any kind, but is especially useful to deal with the complex geometry of Gothic masonry vaults.
LEE, CHANYOUNG; RICHTSMEIER, JOAN T.; KRAFT, REUBEN H.
2017-01-01
Bones of the murine cranial vault are formed by differentiation of mesenchymal cells into osteoblasts, a process that is primarily understood to be controlled by a cascade of reactions between extracellular molecules and cells. We assume that the process can be modeled using Turing’s reaction-diffusion equations, a mathematical model describing the pattern formation controlled by two interacting molecules (activator and inhibitor). In addition to the processes modeled by reaction-diffusion equations, we hypothesize that mechanical stimuli of the cells due to growth of the underlying brain contribute significantly to the process of cell differentiation in cranial vault development. Structural analysis of the surface of the brain was conducted to explore the effects of the mechanical strain on bone formation. We propose a mechanobiological model for the formation of cranial vault bones by coupling the reaction-diffusion model with structural mechanics. The mathematical formulation was solved using the finite volume method. The computational domain and model parameters are determined using a large collection of experimental data that provide precise three dimensional (3D) measures of murine cranial geometry and cranial vault bone formation for specific embryonic time points. The results of this study suggest that mechanical strain contributes information to specific aspects of bone formation. Our mechanobiological model predicts some key features of cranial vault bone formation that were verified by experimental observations including the relative location of ossification centers of individual vault bones, the pattern of cranial vault bone growth over time, and the position of cranial vault sutures. PMID:29225392
49 CFR 192.183 - Vaults: Structural design requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... maintained. (c) Each pipe entering, or within, a regulator vault or pit must be steel for sizes 10 inch (254... vault or pit structure, provision must be made to prevent the passage of gases or liquids through the...
49 CFR 192.183 - Vaults: Structural design requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... maintained. (c) Each pipe entering, or within, a regulator vault or pit must be steel for sizes 10 inch (254... vault or pit structure, provision must be made to prevent the passage of gases or liquids through the...
49 CFR 192.183 - Vaults: Structural design requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... maintained. (c) Each pipe entering, or within, a regulator vault or pit must be steel for sizes 10 inch (254... vault or pit structure, provision must be made to prevent the passage of gases or liquids through the...
49 CFR 192.183 - Vaults: Structural design requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... maintained. (c) Each pipe entering, or within, a regulator vault or pit must be steel for sizes 10 inch (254... vault or pit structure, provision must be made to prevent the passage of gases or liquids through the...
49 CFR 192.183 - Vaults: Structural design requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... maintained. (c) Each pipe entering, or within, a regulator vault or pit must be steel for sizes 10 inch (254... vault or pit structure, provision must be made to prevent the passage of gases or liquids through the...
15. VIEW LOOKING EAST AT UNDERGROUND VAULT, BUILDING 997, UNDER ...
15. VIEW LOOKING EAST AT UNDERGROUND VAULT, BUILDING 997, UNDER CONSTRUCTION. THE VAULTS WERE USED TO STORE TRIGGERS AWAITING OFF-SITE SHIPMENT, OR RETURNED TRIGGERS AWAITING TO BE TRANSPORTED TO A BUILDING FOR RECOVERY OF THE PLUTONIUM. THE VAULT WALLS WERE CONSTRUCTED 14.5 FEET THICK. BUILDING 991, IN THE BACKGROUND, WAS THE FIRST OPERATIONAL BUILDING ON SITE (2/1/52). - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO
Vault Area (original section), east corridor, looking north, showing tops ...
Vault Area (original section), east corridor, looking north, showing tops of individual vaults and vent housings - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC
Muccino, Enrico; Porta, Davide; Magli, Francesca; Cigada, Alfredo; Sala, Remo; Gibelli, Daniele; Cattaneo, Cristina
2013-09-01
As literature is poor in functional synthetic cranial models, in this study, synthetic handmade models of cranial vaults were produced in two different materials (a urethane resin and a self-hardening foam), from multiple bone specimens (eight original cranial vaults: four human and four swine), in order to test their resemblance to bone structure in behavior, during fracture formation. All the vaults were mechanically tested with a 2-kg impact weight and filmed with a high-speed camera. Fracture patterns were homogeneous in all swine vaults and heterogeneous in human vaults, with resin fractures more similar to bone fractures. Mean fracture latency time extrapolated by videos were of 0.75 msec (bone), 1.5 msec (resin), 5.12 msec (foam) for human vaults and of 0.625 msec (bone), 1.87 msec (resin), 3.75 msec (foam) for swine vaults. These data showed that resin models are more similar to bone than foam reproductions, but that synthetic material may behave quite differently from bone as concerns fracture latency times. © 2013 American Academy of Forensic Sciences.
ICPP tank farm closure study. Volume 2: Engineering design files
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-02-01
Volume 2 contains the following topical sections: Tank farm heel flushing/pH adjustment; Grouting experiments for immobilization of tank farm heel; Savannah River high level waste tank 20 closure; Tank farm closure information; Clean closure of tank farm; Remediation issues; Remote demolition techniques; Decision concerning EIS for debris treatment facility; CERCLA/RCRA issues; Area of contamination determination; Containment building of debris treatment facility; Double containment issues; Characterization costs; Packaging and disposal options for the waste resulting from the total removal of the tank farm; Take-off calculations for the total removal of soils and structures at the tank farm; Vessel off-gas systems; Jet-groutedmore » polymer and subsurface walls; Exposure calculations for total removal of tank farm; Recommended instrumentation during retrieval operations; High level waste tank concrete encasement evaluation; Recommended heavy equipment and sizing equipment for total removal activities; Tank buoyancy constraints; Grout and concrete formulas for tank heel solidification; Tank heel pH requirements; Tank cooling water; Evaluation of conservatism of vehicle loading on vaults; Typical vault dimensions and approximately tank and vault void volumes; Radiological concerns for temporary vessel off-gas system; Flushing calculations for tank heels; Grout lift depth analysis; Decontamination solution for waste transfer piping; Grout lift determination for filling tank and vault voids; sprung structure vendor data; Grout flow properties through a 2--4 inch pipe; Tank farm load limitations; NRC low level waste grout; Project data sheet calculations; Dose rates for tank farm closure tasks; Exposure and shielding calculations for grout lines; TFF radionuclide release rates; Documentation of the clean closure of a system with listed waste discharge; and Documentation of the ORNL method of radionuclide concentrations in tanks.« less
Influence of kinematic parameters on pole vault results in top juniors.
Gudelj, Ines; Zagorac, Nebojsa; Babić, Vesna
2013-05-01
The aim of this research was to analyse the kinematic parameters and to ascertain the influence of those parameters on the pole vault result. The entity sample of the research consisted of successful vaults of 30 athletes, whose attempts were recorded at the European Junior Athletics Championships. The examinees performed the vaults as part of the qualification competition for the finale and the finale of the competition itself The examinees were 17-19 years old, and the range of their top results was from 4.90 to 5.30 m. The results of the regression analysis showed a significant influence of the predictor variables on the effective pole vault height. The centre of body mass height was mostly influenced by the following variables: TS - takeoff velocity, LSS - last step velocity, PSS - penultimate step velocity, TAPR - trunk angle at the moment of the pole release. The following variables had lesser, but still a significant influence: CBMDM - centre of body mass distance at the pole release moment, and MCMVV - time of pole straightening. Generally, the information gained by this research indicates the significant influence of the kinematic parameters on the pole vault result. Therefore, the conclusion is that the result efficacy in the pole vault is primarily determined by the variables defined by the motor capabilities, but also by the indicators determining the vault activity realization technique. The variables that define the body position during the pole release (trunk angle and centre of mass distance) have heomost significant influence on the vault performance technique, while the motor capabilities influence the last two run up steps velocity, take off speed and the time of pole straightening.
Chovalopoulou, Maria-Eleni; Valakos, Efstratios D; Manolis, Sotiris K
2016-06-01
The aim of this study is to assess sexual dimorphism of adult crania in the vault and midsagittal curve of the vault using three-dimensional geometric morphometric methods. The study sample consisted of 176 crania of known sex (94 males, 82 females) belonging to individuals who lived during the 20th century in Greece. The three-dimensional co-ordinates of 31 ecto-cranial landmarks and 30 semi-landmarks were digitized using a MicroScribe 3DX contact digitizer. Generalized Procrustes analysis (GPA) was used to obtain size and shape variables for statistical analysis. Shape, size and form analyses were carried out by logistic regression and three discriminant function analyses. Results indicate that there are shape differences between sexes. Females in the region of the parietal bones are narrower and the axis forming the frontal and occipital bones is more elongated; the frontal bone is more vertical. Sex-specific shape differences give better classification results in the vault (79%) compared with the midsagittal curve of the neurocranium (68.8%). Size alone yielded better results for cranial vault (82%), while for the midsagittal curve of the vault the result is poorer (68.1%). As anticipated, the classification accuracy improves when both size and shape are combined (89.2% for vault, and 79.4% for midsagittal curve of the vault). These latter findings imply that, in contrast to the midsagittal curve of the neurocranium, the shape of the cranial vault can be used as an indicator of sex in the modern Greek population. Copyright © 2016. Published by Elsevier GmbH.
Waste Management Project fiscal year 1998 multi-year work plan, WBS 1.2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobsen, P.H.
The Waste Management Project manages and integrates (non-TWRS) waste management activities at the site. Activities include management of Hanford wastes as well as waste transferred to Hanford from other DOE, Department of Defense, or other facilities. This work includes handling, treatment, storage, and disposal of radioactive, nonradioactive, hazardous, and mixed solid and liquid wastes. Major Waste Management Projects are the Solid Waste Project, Liquid Effluents Project, and Analytical Services. Existing facilities (e.g., grout vaults and canyons) shall be evaluated for reuse for these purposes to the maximum extent possible.
CREM monitoring: a wireless RF application
NASA Astrophysics Data System (ADS)
Valencia, J. D.; Burghard, B. J.; Skorpik, J. R.; Silvers, K. L.; Schwartz, M. J.
2005-05-01
Recent security lapses within the Department of Energy laboratories prompted the establishment and implementation of additional procedures and training for operations involving classified removable electronic media (CREM) storage. In addition, the definition of CREM has been expanded and the number of CREM has increased significantly. Procedures now require that all CREM be inventoried and accounted for on a weekly basis. Weekly inventories consist of a physical comparison of each item against the reportable inventory listing. Securing and accounting for CREM is a continuous challenge for existing security systems. To address this challenge, an innovative framework, encompassing a suite of technologies, has been developed by Pacific Northwest National Laboratory (PNNL) to monitor, track, and locate CREM in safes, vaults, and storage areas. This Automated Removable Media Observation and Reporting (ARMOR)framework, described in this paper, is an extension of an existing PNNL program, SecureSafe. The key attributes of systems built around the ARMOR framework include improved accountability, reduced risk of human error, improved accuracy and timeliness of inventory data, and reduced costs. ARMOR solutions require each CREM to be tagged with a unique electronically readable ID code. Inventory data is collected from tagged CREM at regular intervals and upon detection of an access event. Automated inventory collection and report generation eliminates the need for hand-written inventory sheets and allows electronic transfer of the collected inventory data to a modern electronic reporting system. An electronic log of CREM access events is maintained, providing enhanced accountability for daily/weekly checks, routine audits, and follow-up investigations.
Cost estimates and economic evaluations for conceptual LLRW disposal facility designs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baird, R.D.; Chau, N.; Breeds, C.D.
1995-12-31
Total life-cycle costs were estimated in support of the New York LLRW Siting Commission`s project to select a disposal method from four near-surface LLRW disposal methods (namely, uncovered above-grade vaults, covered above-grade vaults, below-grade vaults, and augered holes) and two mined methods (namely, vertical shaft mines and drift mines). Conceptual designs for the disposal methods were prepared and used as the basis for the cost estimates. Typical economic performance of each disposal method was assessed. Life-cycle costs expressed in 1994 dollars ranged from $ 1,100 million (for below-grade vaults and both mined disposal methods) to $2,000 million (for augered holes).more » Present values ranged from $620 million (for below-grade vaults) to $ 1,100 million (for augered holes).« less
Optimal technique for maximal forward rotating vaults in men's gymnastics.
Hiley, Michael J; Jackson, Monique I; Yeadon, Maurice R
2015-08-01
In vaulting a gymnast must generate sufficient linear and angular momentum during the approach and table contact to complete the rotational requirements in the post-flight phase. This study investigated the optimization of table touchdown conditions and table contact technique for the maximization of rotation potential for forwards rotating vaults. A planar seven-segment torque-driven computer simulation model of the contact phase in vaulting was evaluated by varying joint torque activation time histories to match three performances of a handspring double somersault vault by an elite gymnast. The closest matching simulation was used as a starting point to maximize post-flight rotation potential (the product of angular momentum and flight time) for a forwards rotating vault. It was found that the maximized rotation potential was sufficient to produce a handspring double piked somersault vault. The corresponding optimal touchdown configuration exhibited hip flexion in contrast to the hyperextended configuration required for maximal height. Increasing touchdown velocity and angular momentum lead to additional post-flight rotation potential. By increasing the horizontal velocity at table touchdown, within limits obtained from recorded performances, the handspring double somersault tucked with one and a half twists, and the handspring triple somersault tucked became theoretically possible. Copyright © 2015 Elsevier B.V. All rights reserved.
Zheng, Qian-Yin; Xu, Wen; Liang, Guan-Lu; Wu, Jing; Shi, Jun-Ting
2016-01-01
To investigate the correlation between the preoperative biometric parameters of the anterior segment and the vault after implantable Collamer lens (ICL) implantation via this retrospective study. Retrospective clinical study. A total of 78 eyes from 41 patients who underwent ICL implantation surgery were included in this study. Preoperative biometric parameters, including white-to-white (WTW) diameter, central corneal thickness, keratometer, pupil diameter, anterior chamber depth, sulcus-to-sulcus diameter, anterior chamber area (ACA) and central curvature radius of the anterior surface of the lens (Lenscur), were measured. Lenscur and ACA were measured with Rhinoceros 5.0 software on the image scanned with ultrasound biomicroscopy (UBM). The vault was assessed by UBM 3 months after surgery. Multiple stepwise regression analysis was employed to identify the variables that were correlated with the vault. The results showed that the vault was correlated with 3 variables: ACA (22.4 ± 4.25 mm2), WTW (11.36 ± 0.29 mm) and Lenscur (9.15 ± 1.21 mm). The regressive equation was: vault (mm) = 1.785 + 0.017 × ACA + 0.051 × Lenscur - 0.203 × WTW. Biometric parameters of the anterior segment (ACA, WTW and Lenscur) can predict the vault after ICL implantation using a new regression equation. © 2016 The Author(s) Published by S. Karger AG, Basel.
Do, Nhan V; Barnhill, Rick; Heermann-Do, Kimberly A; Salzman, Keith L; Gimbel, Ronald W
2011-01-01
To design, build, implement, and evaluate a personal health record (PHR), tethered to the Military Health System, that leverages Microsoft® HealthVault and Google® Health infrastructure based on user preference. A pilot project was conducted in 2008-2009 at Madigan Army Medical Center in Tacoma, Washington. Our PHR was architected to a flexible platform that incorporated standards-based models of Continuity of Document and Continuity of Care Record to map Department of Defense-sourced health data, via a secure Veterans Administration data broker, to Microsoft® HealthVault and Google® Health based on user preference. The project design and implementation were guided by provider and patient advisory panels with formal user evaluation. The pilot project included 250 beneficiary users. Approximately 73.2% of users were < 65 years of age, and 38.4% were female. Of the users, 169 (67.6%) selected Microsoft® HealthVault, and 81 (32.4%) selected Google® Health as their PHR of preference. Sample evaluation of users reflected 100% (n = 60) satisfied with convenience of record access and 91.7% (n = 55) satisfied with overall functionality of PHR. Key lessons learned related to data-transfer decisions (push vs pull), purposeful delays in reporting sensitive information, understanding and mapping PHR use and clinical workflow, and decisions on information patients may choose to share with their provider. Currently PHRs are being viewed as empowering tools for patient activation. Design and implementation issues (eg, technical, organizational, information security) are substantial and must be thoughtfully approached. Adopting standards into design can enhance the national goal of portability and interoperability.
Effect of materials and manufacturing on the bending stiffness of vaulting poles
NASA Astrophysics Data System (ADS)
Davis, C. L.; Kukureka, S. N.
2012-09-01
The increase in the world record height achieved in pole vaulting can be related to the improved ability of the athletes, in terms of their fitness and technique, and to the change in materials used to construct the pole. For example in 1960 there was a change in vaulting pole construction from bamboo to glass fibre reinforced polymer (GFRP) composites. The lighter GFRP pole enabled the athletes to have a faster run-up, resulting in a greater take-off speed, giving them more kinetic energy to convert into potential energy and hence height. GFRP poles also have a much higher failure stress than bamboo, so the poles were engineered to bend under the load of the athlete, thereby storing elastic strain energy that can be released as the pole straightens, resulting in greater energy efficiency. The bending also allowed athletes to change their vaulting technique from a style that involved the body remaining almost upright during the vault to one where the athlete goes over the bar with their feet upwards. Modern vaulting poles can be made from GFRP and/or carbon fibre reinforced polymer (CFRP) composites. The addition of carbon fibres maintains the mechanical properties of the pole, but allows a reduction in the weight. The number and arrangement of the fibres determines the mechanical properties, in particular the bending stiffness. Vaulting poles are also designed for an individual athlete to take into account each athlete’s ability and physical characteristics. The poles are rated by ‘weight’ to allow athletes to select an appropriate pole for their ability. This paper will review the development of vaulting poles and the requirements to maximize performance. The properties (bending stiffness and pre-bend) and microstructure (fibre volume fraction and lay-up) of typical vaulting poles will be discussed. Originally published as Davis C L and Kukureka S N (2004) Effect of materials and manufacturing on the bending stiffness of vaulting poles The Engineering of Sport 5 ed M Hubbard, R D Mehta and J M Pallis (Sheffield: ISEA). Republished here with permission from ISEA.
Kochanowicz, Andrzej; Kochanowicz, Kazimierz; Mieszkowski, Jan; Aschenbrenner, Piotr; Bielec, Grzegorz; Szark-Eckardt, Mirosława
2016-01-01
Abstract The aim of the study was to define the relationship between maximal power of lower limbs, the biomechanics of the forward handspring vault and the score received during a gymnastics competition. The research involved 42 gymnasts aged 9-11 years competing in the Poland’s Junior Championships. The study consisted of three stages: first -estimating the level of indicators of maximal power of lower limbs tested on a force plate during the countermovement jump; second - estimating the level of biomechanical indicators of the front handspring vault. For both mentioned groups of indicators and the score received by gymnasts during the vault, linear correlation analyses were made. The last stage consisted of conducting multiple regression analysis in order to predict the performance level of the front handspring vault. Results showed a positive correlation (0.401, p < 0.05) of lower limbs’ maximal power (1400 ± 502 W) with the judges’ score for the front handstand vault (13.38 ± 1.02 points). However, the highest significant (p < 0.001) correlation with the judges’ score was revealed in the angle of the hip joint in the second phase of the flight (196.00 ± 16.64°) and the contact time of hands with the vault surface (0.264 ± 0.118 s), where correlation coefficients were: -0.671 and -0.634, respectively. In conclusion, the angles of the hip joint in the second phase of the flight and when the hands touched the vault surface proved to be the most important indicators for the received score. PMID:28149408
49 CFR 192.189 - Vaults: Drainage and waterproofing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.189 Vaults: Drainage and waterproofing. (a) Each vault must be designed so as to minimize... applicable requirements of Class 1, Group D, of the National Electrical Code, ANSI/NFPA 70. [35 FR 13257, Aug...
NASA Astrophysics Data System (ADS)
Gattesco, Natalino; Boem, Ingrid
2017-10-01
The paper investigates the effectiveness of a modern reinforcement technique based on a Glass Fiber-Reinforced Mortar (GFRM) for the enhancement of the performances of existing masonry vaults subjected to horizontal seismic actions. In fact, the authors recently evidenced, through numerical simulations, that the typical simplified loading patterns generally adopted in the literature for the experimental tests, based on concentrated vertical loads at 1/4 of the span, are not reliable for such a purpose, due to an unrealistic stress distribution. Thus, experimental quasi-static cyclic tests on full-scale masonry vaults based on a specific setup, designed to apply a horizontal load pattern proportional to the mass, were performed. Three samples were tested: an unreinforced vault, a vault reinforced at the extrados and a vault reinforced at the intrados. The experimental results demonstrated the technique effectiveness in both strength and ductility. Moreover, numerical simulations were performed by adopting a simplified FE, smear-crack model, evidencing the good reliability of the prediction by comparison with the experimental results.
D’Haese, Pierre-François; Pallavaram, Srivatsan; Li, Rui; Remple, Michael S.; Kao, Chris; Neimat, Joseph S.; Konrad, Peter E.; Dawant, Benoit M.
2010-01-01
A number of methods have been developed to assist surgeons at various stages of deep brain stimulation (DBS) therapy. These include construction of anatomical atlases, functional databases, and electrophysiological atlases and maps. But, a complete system that can be integrated into the clinical workflow has not been developed. In this paper we present a system designed to assist physicians in pre-operative target planning, intra-operative target refinement and implantation, and post-operative DBS lead programming. The purpose of this system is to centralize the data acquired a the various stages of the procedure, reduce the amount of time needed at each stage of the therapy, and maximize the efficiency of the entire process. The system consists of a central repository (CranialVault), of a suite of software modules called CRAVE (CRAnialVault Explorer) that permit data entry and data visualization at each stage of the therapy, and of a series of algorithms that permit the automatic processing of the data. The central repository contains image data for more than 400 patients with the related pre-operative plans and position of the final implants and about 10,550 electrophysiological data points (micro-electrode recordings or responses to stimulations) recorded from 222 of these patients. The system has reached the stage of a clinical prototype that is being evaluated clinically at our institution. A preliminary quantitative validation of the planning component of the system performed on 80 patients who underwent the procedure between January 2009 and December 2009 shows that the system provides both timely and valuable information. PMID:20732828
Health physics challenges involved with opening a "seventeen-inch" concrete waste vault.
Sullivan, Patrick T; Pizzulli, Michelle
2005-05-01
This paper describes the various activities involved with opening a sealed legacy "Seventeen-inch" concrete vault and the health physics challenges and solutions employed. As part of a legacy waste stream that was removed from the former Hazardous Waste Management Facility at Brookhaven National Laboratory, the "Seventeen-inch" concrete vault labeled 1-95 was moved to the new Waste Management Facility for ultimate disposal. Because the vault contained 239Pu foils with a total activity in excess of the transuranic waste limits, the foils needed to be removed and repackaged for disposal. Conventional diamond wire saws could not be used because of facility constraints, so this project relied mainly on manual techniques. The planning and engineering controls put in place enabled personnel to open the vault and remove the waste while keeping dose as low as reasonably achievable.
1972-01-01
This cutaway illustration shows the characteristics and basic elements of the Skylab Orbiter Workshop (OWS). The OWS was divided into two major compartments. The lower level provided crew accommodations for sleeping, food preparation and consumption, hygiene, waste processing and disposal, and performance of certain experiments. The upper level consisted of a large work area and housed water storage tanks, a food freezer, storage vaults for film, scientific airlocks, mobility and stability experiment equipment, and other experimental equipment. The compartment below the crew quarters was a container for liquid and solid waste and trash accumulated throughout the mission. A solar array, consisting of two wings covered on one side with solar cells, was mounted outside the workshop to generate electrical power to augment the power generated by another solar array mounted on the solar observatory. Thrusters were provided at one end of the workshop for short-term control of the attitude of the space station.
Skylab Orbiter Workshop Illustration
NASA Technical Reports Server (NTRS)
1972-01-01
This cutaway illustration shows the characteristics and basic elements of the Skylab Orbiter Workshop (OWS). The OWS was divided into two major compartments. The lower level provided crew accommodations for sleeping, food preparation and consumption, hygiene, waste processing and disposal, and performance of certain experiments. The upper level consisted of a large work area and housed water storage tanks, a food freezer, storage vaults for film, scientific airlocks, mobility and stability experiment equipment, and other experimental equipment. The compartment below the crew quarters was a container for liquid and solid waste and trash accumulated throughout the mission. A solar array, consisting of two wings covered on one side with solar cells, was mounted outside the workshop to generate electrical power to augment the power generated by another solar array mounted on the solar observatory. Thrusters were provided at one end of the workshop for short-term control of the attitude of the space station.
Cutaway View of Skylab Orbital Workshop
NASA Technical Reports Server (NTRS)
1972-01-01
This illustration is a cutaway view of the Orbital Workshop (OWS) showing details of the living and working quarters. The OWS was divided into two major compartments. The lower level provided crew accommodations for sleeping, food preparation and consumption, hygiene, waste processing and disposal, and performance of certain experiments. The upper level consisted of a large work area and housed water storage tanks, a food freezer, storage vaults for film, scientific airlocks, mobility and stability experiment equipment, and other experimental equipment . The compartment below the crew quarters was a container for liquid and solid waste and trash accumulated throughout the mission. A solar array, consisting of two wings covered on one side with solar cells, was mounted outside the workshop to generate electrical power to augment the power generated by another solar array mounted on the solar observatory. Thrusters were provided at one end of the workshop for short-term control of the attitude of the space station.
Shielding design of the Mayo Clinic Scottsdale cyclotron vault
NASA Astrophysics Data System (ADS)
Riper, Kenneth A. Van; Metzger, Robert L.; Nelson, Kevin
2017-09-01
Mayo Clinic Scottsdale (Scottsdale, Arizona) is building a cyclotron vault containing a cyclotron with adjacent targets and a beam line leading to an external target. The targets are irradiated by high energy (15 to 16.5 MeV) protons for the production of radioisotopes. We performed Monte Carlo radiation transport simulations to calculate the radiation dose outside of the vault during irradiation of the cyclotron and external targets. We present the Monte Carlo model including the geometry, sources, and variance reduction methods. Mesh tallies surrounding the vault show the external dose rate is within acceptable limits.
93. View of transmitter building no. 102 view from second ...
93. View of transmitter building no. 102 view from second floor at grid lines 102-J-L, looking down at capacitor vaults on left and Klystron tube vaults on right showing future square attachment blockouts for waveguide connections at top. RCA Services Company 27 October, 1960, official photograph BMEWS Project by unknown photograph, Photographic Services, Riverton, NJ, BMEWS, clear as negative no. A-1371. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
The 193-Kd Vault Protein, Vparp, Is a Novel Poly(Adp-Ribose) Polymerase
Kickhoefer, Valerie A.; Siva, Amara C.; Kedersha, Nancy L.; Inman, Elisabeth M.; Ruland, Cristina; Streuli, Michel; Rome, Leonard H.
1999-01-01
Mammalian vaults are ribonucleoprotein (RNP) complexes, composed of a small ribonucleic acid and three proteins of 100, 193, and 240 kD in size. The 100-kD major vault protein (MVP) accounts for >70% of the particle mass. We have identified the 193-kD vault protein by its interaction with the MVP in a yeast two-hybrid screen and confirmed its identity by peptide sequence analysis. Analysis of the protein sequence revealed a region of ∼350 amino acids that shares 28% identity with the catalytic domain of poly(ADP-ribose) polymerase (PARP). PARP is a nuclear protein that catalyzes the formation of ADP-ribose polymers in response to DNA damage. The catalytic domain of p193 was expressed and purified from bacterial extracts. Like PARP, this domain is capable of catalyzing a poly(ADP-ribosyl)ation reaction; thus, the 193-kD protein is a new PARP. Purified vaults also contain the poly(ADP-ribosyl)ation activity, indicating that the assembled particle retains enzymatic activity. Furthermore, we show that one substrate for this vault-associated PARP activity is the MVP. Immunofluorescence and biochemical data reveal that p193 protein is not entirely associated with the vault particle, suggesting that it may interact with other protein(s). A portion of p193 is nuclear and localizes to the mitotic spindle. PMID:10477748
Risk Management in the Original Extreme Sporting Event: The Pole Vault
ERIC Educational Resources Information Center
Bemiller, Jim; Hardin, Robin
2010-01-01
The pole vault was considered the ultimate test of physical ability and daring before the advent of modern extreme sports such as skateboarding, snowboarding, and mountain biking. The inherent risks of the pole vault have been well documented. The National Center for Catastrophic Sport Injury Research reported in 2007 that the catastrophic injury…
Mapping genetic variants for cranial vault shape in humans.
Roosenboom, Jasmien; Lee, Myoung Keun; Hecht, Jacqueline T; Heike, Carrie L; Wehby, George L; Christensen, Kaare; Feingold, Eleanor; Marazita, Mary L; Maga, A Murat; Shaffer, John R; Weinberg, Seth M
2018-01-01
The shape of the cranial vault, a region comprising interlocking flat bones surrounding the cerebral cortex, varies considerably in humans. Strongly influenced by brain size and shape, cranial vault morphology has both clinical and evolutionary relevance. However, little is known about the genetic basis of normal vault shape in humans. We performed a genome-wide association study (GWAS) on three vault measures (maximum cranial width [MCW], maximum cranial length [MCL], and cephalic index [CI]) in a sample of 4419 healthy individuals of European ancestry. All measures were adjusted by sex, age, and body size, then tested for association with genetic variants spanning the genome. GWAS results for the two cohorts were combined via meta-analysis. Significant associations were observed at two loci: 15p11.2 (lead SNP rs2924767, p = 2.107 × 10-8) for MCW and 17q11.2 (lead SNP rs72841279, p = 5.29 × 10-9) for MCL. Additionally, 32 suggestive loci (p < 5x10-6) were observed. Several candidate genes were located in these loci, such as NLK, MEF2A, SOX9 and SOX11. Genome-wide linkage analysis of cranial vault shape in mice (N = 433) was performed to follow-up the associated candidate loci identified in the human GWAS. Two loci, 17q11.2 (c11.loc44 in mice) and 17q25.1 (c11.loc74 in mice), associated with cranial vault size in humans, were also linked with cranial vault size in mice (LOD scores: 3.37 and 3.79 respectively). These results provide further insight into genetic pathways and mechanisms underlying normal variation in human craniofacial morphology.
Mapping genetic variants for cranial vault shape in humans
Lee, Myoung Keun; Hecht, Jacqueline T.; Heike, Carrie L.; Wehby, George L.; Christensen, Kaare; Feingold, Eleanor; Marazita, Mary L.; Weinberg, Seth M.
2018-01-01
The shape of the cranial vault, a region comprising interlocking flat bones surrounding the cerebral cortex, varies considerably in humans. Strongly influenced by brain size and shape, cranial vault morphology has both clinical and evolutionary relevance. However, little is known about the genetic basis of normal vault shape in humans. We performed a genome-wide association study (GWAS) on three vault measures (maximum cranial width [MCW], maximum cranial length [MCL], and cephalic index [CI]) in a sample of 4419 healthy individuals of European ancestry. All measures were adjusted by sex, age, and body size, then tested for association with genetic variants spanning the genome. GWAS results for the two cohorts were combined via meta-analysis. Significant associations were observed at two loci: 15p11.2 (lead SNP rs2924767, p = 2.107 × 10−8) for MCW and 17q11.2 (lead SNP rs72841279, p = 5.29 × 10−9) for MCL. Additionally, 32 suggestive loci (p < 5x10-6) were observed. Several candidate genes were located in these loci, such as NLK, MEF2A, SOX9 and SOX11. Genome-wide linkage analysis of cranial vault shape in mice (N = 433) was performed to follow-up the associated candidate loci identified in the human GWAS. Two loci, 17q11.2 (c11.loc44 in mice) and 17q25.1 (c11.loc74 in mice), associated with cranial vault size in humans, were also linked with cranial vault size in mice (LOD scores: 3.37 and 3.79 respectively). These results provide further insight into genetic pathways and mechanisms underlying normal variation in human craniofacial morphology. PMID:29698431
Cranial vault thickness in primates: Homo erectus does not have uniquely thick vault bones.
Copes, Lynn E; Kimbel, William H
2016-01-01
Extremely thick cranial vaults have been noted as a diagnostic characteristic of Homo erectus since the first fossil of the species was identified, but relatively little work has been done on elucidating its etiology or variation across fossils, living humans, or extant non-human primates. Cranial vault thickness (CVT) is not a monolithic trait, and the responsiveness of its layers to environmental stimuli is unknown. We obtained measurements of cranial vault thickness in fossil hominins from the literature and supplemented those data with additional measurements taken on African fossil specimens. Total CVT and the thickness of the cortical and diploë layers individually were compared to measures of CVT in extant species measured from more than 500 CT scans of human and non-human primates. Frontal and parietal CVT in fossil primates was compared to a regression of CVT on cranial capacity calculated for extant species. Even after controlling for cranial capacity, African and Asian H. erectus do not have uniquely high frontal or parietal thickness residuals, either among hominins or extant primates. Extant primates with residual CVT thickness similar to or exceeding H. erectus (depending on the sex and bone analyzed) include Nycticebus coucang, Perodicticus potto, Alouatta caraya, Lophocebus albigena, Galago alleni, Mandrillus sphinx, and Propithecus diadema. However, the especially thick vaults of extant non-human primates that overlap with H. erectus values are composed primarily of cortical bone, while H. erectus and other hominins have diploë-dominated vault bones. Thus, the combination of thick vaults comprised of a thickened diploë layer may be a reliable autapomorphy for members of the genus Homo. Copyright © 2015 Elsevier Ltd. All rights reserved.
Reinstein, Dan Z; Lovisolo, Carlo F; Archer, Timothy J; Gobbe, Marine
2013-01-01
To compare vault height predictability of Implantable Collamer Lens (ICL; Staar Surgical) sizing using a sulcus diameter-based formula or the manufacturer-recommended white-to-white-based method. In 50 myopic eyes, ICL size was calculated using both a formula including sulcus diameter and the traditional formula based on white-to-white diameter. Sulcus diameter was measured using Artemis 2 very high-frequency (VHF) digital ultrasound (ArcScan Inc). Implantation was based on the sulcus diameter derived size. Actual postoperative vault height achieved was measured by VHF digital ultrasound scanning. Circle segment trigonometry was used to calculate the vault height that would have resulted had lens sizing been based on the white-to-white formula. The same lens size would have been used in 60% of eyes, a smaller lens would have been used in 34% of eyes and a larger lens in 6% of eyes had lens sizing been based on the white-to-white formula. Mean vault for eyes with lenses sized using the sulcus diameter formula was 0.37±0.16 mm (range: 0.08 to 0.92 mm), with 2% <0.09 mm, the recognized low-vault height for risk of cataract. Circle segment trigonometry predicted that the vault height would have been 0.24±0.28 mm (range: -0.31 to 0.92 mm), with 26% <0.09 mm had lens sizing been based on the white-to-white formula. Significantly better predictability of postoperative vault height was achieved by including sulcus diameter into the ICL sizing formula compared with using the traditional white-to-white-based formula. Copyright 2013, SLACK Incorporated.
Development of high integrity, maximum durability concrete structures for LLW disposal facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, W.P.
1992-05-01
A number of disposal facilities for Low-Level Radioactive Wastes have been planned for the Savannah River Site. Design has been completed for disposal vaults for several waste classifications and construction is nearly complete or well underway on some facilities. Specific design criteria varies somewhat for each waste classification. All disposal units have been designed as below-grade concrete vaults, although the majority will be above ground for many years before being encapsulated with earth at final closure. Some classes of vaults have a minimum required service life of 100 years. All vaults utilize a unique blend of cement, blast furnace slagmore » and pozzolan. The design synthesizes the properties of the concrete mix with carefully planned design details and construction methodologies to (1) eliminate uncontrolled cracking; (2) minimize leakage potential; and (3) maximize durability. The first of these vaults will become operational in 1992. 9 refs.« less
Development of high integrity, maximum durability concrete structures for LLW disposal facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, W.P.
1992-01-01
A number of disposal facilities for Low-Level Radioactive Wastes have been planned for the Savannah River Site. Design has been completed for disposal vaults for several waste classifications and construction is nearly complete or well underway on some facilities. Specific design criteria varies somewhat for each waste classification. All disposal units have been designed as below-grade concrete vaults, although the majority will be above ground for many years before being encapsulated with earth at final closure. Some classes of vaults have a minimum required service life of 100 years. All vaults utilize a unique blend of cement, blast furnace slagmore » and pozzolan. The design synthesizes the properties of the concrete mix with carefully planned design details and construction methodologies to (1) eliminate uncontrolled cracking; (2) minimize leakage potential; and (3) maximize durability. The first of these vaults will become operational in 1992. 9 refs.« less
Uterosacral ligament vaginal vault suspension: anatomy, outcome and surgical considerations.
Yazdany, Taji; Bhatia, Narender
2008-10-01
With aging populations, primary pelvic organ and recurrent pelvic organ prolapse have become a large-scale public health concern. Surgical options for patients include both abdominal and vaginal approaches, each with its own safety and efficacy profiles. This review summarizes the most recent anatomic, surgical and outcome data for uterosacral ligament vault suspension. It offers data on methods to avoid complications and difficult surgical scenarios. Uterosacral ligament suspension allows reattachment of the vaginal vault high within the pelvis. New modifications in technique including the extraperitoneal and laparoscopic approaches allow surgeons more freedom when planning surgery. Five-year data on the durability of the procedure make it a viable surgical option. As a technique widely used by many pelvic reconstructive surgeons, uterosacral ligament vault suspension provides a safe, anatomically correct and durable approach to uterine and vault prolapse. It requires advanced surgical training and an intimate understanding of pelvic anatomy to avoid and identify ureteral injury.
Barnhill, Rick; Heermann-Do, Kimberly A; Salzman, Keith L; Gimbel, Ronald W
2011-01-01
Objective To design, build, implement, and evaluate a personal health record (PHR), tethered to the Military Health System, that leverages Microsoft® HealthVault and Google® Health infrastructure based on user preference. Materials and methods A pilot project was conducted in 2008–2009 at Madigan Army Medical Center in Tacoma, Washington. Our PHR was architected to a flexible platform that incorporated standards-based models of Continuity of Document and Continuity of Care Record to map Department of Defense-sourced health data, via a secure Veterans Administration data broker, to Microsoft® HealthVault and Google® Health based on user preference. The project design and implementation were guided by provider and patient advisory panels with formal user evaluation. Results The pilot project included 250 beneficiary users. Approximately 73.2% of users were <65 years of age, and 38.4% were female. Of the users, 169 (67.6%) selected Microsoft® HealthVault, and 81 (32.4%) selected Google® Health as their PHR of preference. Sample evaluation of users reflected 100% (n=60) satisfied with convenience of record access and 91.7% (n=55) satisfied with overall functionality of PHR. Discussion Key lessons learned related to data-transfer decisions (push vs pull), purposeful delays in reporting sensitive information, understanding and mapping PHR use and clinical workflow, and decisions on information patients may choose to share with their provider. Conclusion Currently PHRs are being viewed as empowering tools for patient activation. Design and implementation issues (eg, technical, organizational, information security) are substantial and must be thoughtfully approached. Adopting standards into design can enhance the national goal of portability and interoperability. PMID:21292705
PIMS-Universal Payload Information Management
NASA Technical Reports Server (NTRS)
Elmore, Ralph; McNair, Ann R. (Technical Monitor)
2002-01-01
As the overall manager and integrator of International Space Station (ISS) science payloads and experiments, the Payload Operations Integration Center (POIC) at Marshall Space Flight Center had a critical need to provide an information management system for exchange and management of ISS payload files as well as to coordinate ISS payload related operational changes. The POIC's information management system has a fundamental requirement to provide secure operational access not only to users physically located at the POIC, but also to provide collaborative access to remote experimenters and International Partners. The Payload Information Management System (PIMS) is a ground based electronic document configuration management and workflow system that was built to service that need. Functionally, PIMS provides the following document management related capabilities: 1. File access control, storage and retrieval from a central repository vault. 2. Collect supplemental data about files in the vault. 3. File exchange with a PMS GUI client, or any FTP connection. 4. Files placement into an FTP accessible dropbox for pickup by interfacing facilities, included files transmitted for spacecraft uplink. 5. Transmission of email messages to users notifying them of new version availability. 6. Polling of intermediate facility dropboxes for files that will automatically be processed by PIMS. 7. Provide an API that allows other POIC applications to access PIMS information. Functionally, PIMS provides the following Change Request processing capabilities: 1. Ability to create, view, manipulate, and query information about Operations Change Requests (OCRs). 2. Provides an adaptable workflow approval of OCRs with routing through developers, facility leads, POIC leads, reviewers, and implementers. Email messages can be sent to users either involving them in the workflow process or simply notifying them of OCR approval progress. All PIMS document management and OCR workflow controls are coordinated through and routed to individual user's "to do" list tasks. A user is given a task when it is their turn to perform some action relating to the approval of the Document or OCR. The user's available actions are restricted to only functions available for the assigned task. Certain actions, such as review or action implementation by non-PIMS users, can also be coordinated through automated emails.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quigley, K.D.; Butterworth, St.W.; Lockie, K.A.
2008-07-01
Significant progress has been made at the U.S. Department of Energy (DOE) Idaho National Laboratory (INL) to empty, clean and close radioactive liquid waste storage tanks at the Idaho Nuclear Technology and Engineering Center (INTEC) Tank Farm Facility (TFF). The TFF includes eleven 1,135.6-kL (300,000-gal) underground stainless steel storage tanks and four smaller, 113.5-kL (30,000-gal) stainless steel tanks, along with tank vaults, interconnecting piping, and ancillary equipment. The TFF tanks have historically been used to store a variety of radioactive liquid waste, including wastes associated with past spent nuclear fuel reprocessing. Although four of the large storage tanks remain inmore » use for waste storage, the other seven 1,135.6-kL (300,000-gal) tanks and the four 113.5-kL (30,000-gal) tanks have been emptied of waste, cleaned and filled with grout. A water spray cleaning system was developed and deployed to clean internal tank surfaces and remove remaining tank wastes. The cleaning system was effective in removing all but a very small volume of solid residual waste particles. Recent issuance of an Amended Record of Decision (ROD) in accordance with the National Environmental Policy Act, and a Waste Determination complying with Section 3116 of the Ronald W. Reagan National Defense Authorization Act (NDAA) for Fiscal Year 2005, has allowed commencement of grouting activities on the cleaned tanks. The first three 113.5-kL (30,000-gal) tanks were grouted in the Fall of 2006 and the fourth tank and the seven 1,135.6-kL (300,000-gal) tanks were filled with grout in 2007 to provide long-term stability. It is currently planned that associated tank valve boxes and interconnecting piping, will be stabilized with grout as early as 2008. (authors)« less
Second of three panoramic views of North Base as seen ...
Second of three panoramic views of North Base as seen from top of Building 4500, Control Tower. View looks west (268°) at North Base complex. In foreground is taxiway, with Building 4456 (Fire House No. 4) at right. Building 4452 (Utility Vault) appears in extreme left foreground, with Building 4412 (Liquid Oxygen Repair Facility) and Building 4410 (Liquid Oxygen Storage) in extreme left background. In view over Building 4456 is the "loop" bound by Third, Fourth, A, and B Streets. Concrete slabs are all that remain of military housing constructed in the 1940s. - Edwards Air Force Base, North Base, North Base Road, Boron, Kern County, CA
Comparison of the take-off ground reaction force patterns of the pole vault and the long jump.
Plessa, E I; Rousanoglou, E N; Boudolos, K D
2010-12-01
The take-off is probably the most important phase of the pole vault. The kinematics of pole vault take-off is often described in comparison to the long jump take-off. If a kinetic similarity were also evidenced, the extra loading of carrying the pole could be avoided by using the long jump style take-off drills in pole vault take-off training. However, to our knowledge, a direct comparison of the take-off ground reaction force (GRF) pattern of the two types of jump has not been reported in the scientific or coaching literature. The purpose of this study was to compare the take-off GRF patterns of the support leg in the pole vault and the long jump. Twelve elite women jumpers undertook pole vault and long jump trials. The take-off GRF patterns were recorded by a force plate (Kistler-9286AA). Temporal and force parameters were determined for all three GRF components. Trials were videotaped to determine the take-off kinematics. Paired sample t-tests (SPSS 13.0) were applied (P≤0.05) for comparison between jumps. No significant differences were found in kinematics (P>0.05). Overall, the GRF patterns were similar, although there were particular significant (P≤0.05) differences in contact times, impulses and force peaks. This study provides scientific support for potential use of the long jump take-off drills during technical preparation for the pole vault take-off.
D'Haese, Pierre-François; Pallavaram, Srivatsan; Li, Rui; Remple, Michael S; Kao, Chris; Neimat, Joseph S; Konrad, Peter E; Dawant, Benoit M
2012-04-01
A number of methods have been developed to assist surgeons at various stages of deep brain stimulation (DBS) therapy. These include construction of anatomical atlases, functional databases, and electrophysiological atlases and maps. But, a complete system that can be integrated into the clinical workflow has not been developed. In this paper we present a system designed to assist physicians in pre-operative target planning, intra-operative target refinement and implantation, and post-operative DBS lead programming. The purpose of this system is to centralize the data acquired a the various stages of the procedure, reduce the amount of time needed at each stage of the therapy, and maximize the efficiency of the entire process. The system consists of a central repository (CranialVault), of a suite of software modules called CRAnialVault Explorer (CRAVE) that permit data entry and data visualization at each stage of the therapy, and of a series of algorithms that permit the automatic processing of the data. The central repository contains image data for more than 400 patients with the related pre-operative plans and position of the final implants and about 10,550 electrophysiological data points (micro-electrode recordings or responses to stimulations) recorded from 222 of these patients. The system has reached the stage of a clinical prototype that is being evaluated clinically at our institution. A preliminary quantitative validation of the planning component of the system performed on 80 patients who underwent the procedure between January 2009 and December 2009 shows that the system provides both timely and valuable information. Copyright © 2010 Elsevier B.V. All rights reserved.
Effect of Materials and Manufacturing on the Bending Stiffness of Vaulting Poles
ERIC Educational Resources Information Center
Davis, C. L.; Kukureka, S. N.
2012-01-01
The increase in the world record height achieved in pole vaulting can be related to the improved ability of the athletes, in terms of their fitness and technique, and to the change in materials used to construct the pole. For example in 1960 there was a change in vaulting pole construction from bamboo to glass fibre reinforced polymer (GFRP)…
105. VIEW NORTH FROM SLC3W CABLE TUNNEL INTO CABLE VAULT ...
105. VIEW NORTH FROM SLC-3W CABLE TUNNEL INTO CABLE VAULT AND SLC-3E CABLE TUNNEL. NOTE WOODEN PLANKING ON FLOOR OF TUNNEL AND CABLE TRAYS LINING TUNNEL WALLS. STAIRS ON EAST WALL OF CABLE VAULT LEAD INTO LANDLINE INSTRUMENTATION ROOM. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Hashim, Peter W; Patel, Anup; Yang, Jenny F; Travieso, Roberto; Terner, Jordan; Losee, Joseph E; Pollack, Ian; Jane, John; Jane, John; Kanev, Paul; Mayes, Linda; Duncan, Charles; Bridgett, David J; Persing, John A
2014-09-01
The optimal type of surgical management for isolated sagittal synostosis remains a source of significant debate. There is a paucity of data regarding possible differences in long-term neuropsychological outcomes following treatment with whole-vault cranioplasty or endoscopic strip craniectomy. This study provides the first comparative analysis examining the effects of the two techniques related to long-term intellectual functioning. A total of 70 patients were enrolled in this multicenter study, 29 of whom had previously undergone endoscopic strip craniectomy and 41 of whom had previously undergone whole-vault cranioplasty. All patients completed a battery of neurodevelopmental tests (Beery-Buktenica Developmental Test of Visual-Motor Integration, Wechsler Abbreviated Scale of Intelligence, and Wechsler Fundamentals) to evaluate various domains of neuropsychological function. In a group comparison of those treated before 6 months of age, whole-vault patients obtained higher scores relative to endoscopic strip craniectomy patients on visuomotor integration, full-scale intelligence quotient, verbal intelligence quotient, word reading, and reading comprehension (p < 0.05 for all). When compared against strip craniectomy performed before 3 months of age, the whole-vault group still showed significantly higher scores in verbal intelligence quotient, reading comprehension, and word reading (p < 0.05 for all). The type of surgical intervention for isolated sagittal synostosis impacts long-term neuropsychological outcomes. Patients undergoing early whole-vault cranioplasty attained higher intelligence quotient and achievement scores relative to those undergoing strip craniectomy. Surgical management with whole-vault cranioplasty performed before 6 months of age provides the most favorable long-term intellectual outcomes in patients with isolated sagittal synostosis. Therapeutic, II.
Dose profile modeling of Idaho National Laboratory's active neutron interrogation laboratory.
Chichester, D L; Seabury, E H; Zabriskie, J M; Wharton, J; Caffrey, A J
2009-06-01
A new laboratory has been commissioned at Idaho National Laboratory for performing active neutron interrogation research and development. The facility is designed to provide radiation shielding for deuterium-tritium (DT) fusion (14.1 MeV) neutron generators (2 x 10(8) n/s), deuterium-deuterium (DD) fusion (2.5 MeV) neutron generators (1 x 10(7) n/s), and (252)Cf spontaneous fission neutron sources (6.96 x 10(7) n/s, 30 microg). Shielding at the laboratory is comprised of modular concrete shield blocks 0.76 m thick with tongue-in-groove features to prevent radiation streaming, arranged into one small and one large test vault. The larger vault is designed to allow operation of the DT generator and has walls 3.8m tall, an entrance maze, and a fully integrated electrical interlock system; the smaller test vault is designed for (252)Cf and DD neutron sources and has walls 1.9 m tall and a simple entrance maze. Both analytical calculations and numerical simulations were used in the design process for the building to assess the performance of the shielding walls and to ensure external dose rates are within required facility limits. Dose rate contour plots have been generated for the facility to visualize the effectiveness of the shield walls and entrance mazes and to illustrate the spatial profile of the radiation dose field above the facility and the effects of skyshine around the vaults.
DOSE PROFILE MODELING OF IDAHO NATIONAL LABORATORY’S ACTIVE NEUTRON INTERROGATION TEST FACILITY
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. L. Chichester; E. H. Seabury; J. M. Zabriskie
2009-06-01
A new research and development laboratory has been commissioned at Idaho National Laboratory for performing active neutron interrogation research and development. The facility is designed to provide radiation shielding for DT fusion (14.1 MeV) neutron generators (2 x 108 neutrons per second), DD fusion (2.5 MeV) neutron generators (up to 2 x 106 neutrons per second), and 252Cf spontaneous fission neutron sources (6.7 x 107 neutrons per second, 30 micrograms). Shielding at the laboratory is comprised of modular concrete shield blocks 0.76 m thick with tongue-in-groove features to prevent radiation streaming, arranged into one small and one large test vault.more » The larger vault is designed to allow operation of the DT generator and has walls 3.8 m tall, an entrance maze, and a fully integrated electrical interlock system; the smaller test vault is designed for 252Cf and DD neutron sources and has walls 1.9 m tall and a simple entrance maze. Both analytical calculations and numerical simulations were used in the design process for the building to assess the performance of the shielding walls and to ensure external dose rates are within required facility limits. Dose rate contour plots have been generated for the facility to visualize the effectiveness of the shield wall and entrance maze and to illustrate the spatial profile of the radiation dose field above the facility and the effects of skyshine around the vaults.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
W. L. Poe, Jr.; P.F. Wise
The U.S. Department of Energy (DOE) is preparing a proposal to construct, operate 2nd monitor, and eventually close a repository at Yucca Mountain in Nye County, Nevada, for the geologic disposal of spent nuclear fuel (SNF) and high-level radioactive waste (HLW). As part of this effort, DOE has prepared a viability assessment and an assessment of potential consequences that may exist if the repository is not constructed. The assessment of potential consequences if the repository is not constructed assumes that all SNF and HLW would be left at the generator sites. These include 72 commercial generator sites (three commercial facilitymore » pairs--Salem and Hope Creek, Fitzpatrick and Nine Mile Point, and Dresden and Morris--would share common storage due to their close proximity to each other) and five DOE sites across the country. DOE analyzed the environmental consequences of the effects of the continued storage of these materials at these sites in a report titled Continued Storage Analysis Report (CSAR; Reference 1 ) . The CSAR analysis includes a discussion of the degradation of these materials when exposed to the environment. This document describes the environmental parameters that influence the degradation analyzed in the CSAR. These include temperature, relative humidity, precipitation chemistry (pH and chemical composition), annual precipitation rates, annual number of rain-days, and annual freeze/thaw cycles. The document also tabulates weather conditions for each storage site, evaluates the degradation of concrete storage modules and vaults in different regions of the country, and provides a thermal analysis of commercial SNF in storage.« less
2010-04-06
Assembly began April 1, 2010, for NASA Juno spacecraft. Workers at Lockheed Martin Space Systems in Denver, Colorado are moving into place the vault that will protect the spacecraft sensitive electronics from Jupiter intense radiation belts.
Effects of Run-Up Velocity on Performance, Kinematics, and Energy Exchanges in The Pole Vault
Linthorne, Nicholas P.; Weetman, A. H. Gemma
2012-01-01
This study examined the effect of run-up velocity on the peak height achieved by the athlete in the pole vault and on the corresponding changes in the athlete's kinematics and energy exchanges. Seventeen jumps by an experienced male pole vaulter were video recorded in the sagittal plane and a wide range of run-up velocities (4.5-8.5 m/s) was obtained by setting the length of the athlete's run-up (2-16 steps). A selection of performance variables, kinematic variables, energy variables, and pole variables were calculated from the digitized video data. We found that the athlete's peak height increased linearly at a rate of 0.54 m per 1 m/s increase in run-up velocity and this increase was achieved through a combination of a greater grip height and a greater push height. At the athlete's competition run-up velocity (8.4 m/s) about one third of the rate of increase in peak height arose from an increase in grip height and about two thirds arose from an increase in push height. Across the range of run-up velocities examined here the athlete always performed the basic actions of running, planting, jumping, and inverting on the pole. However, he made minor systematic changes to his jumping kinematics, vaulting kinematics, and selection of pole characteristics as the run-up velocity increased. The increase in run-up velocity and changes in the athlete's vaulting kinematics resulted in substantial changes to the magnitudes of the energy exchanges during the vault. A faster run-up produced a greater loss of energy during the take-off, but this loss was not sufficient to negate the increase in run-up velocity and the increase in work done by the athlete during the pole support phase. The athlete therefore always had a net energy gain during the vault. However, the magnitude of this gain decreased slightly as run-up velocity increased. Key pointsIn the pole vault the optimum technique is to run-up as fast as possible.The athlete's vault height increases at a rate of about 0.5 m per 1 m/s increase in run-up velocity.The increase in vault height is achieved through a greater grip height and a greater push height. At the athlete's competition run-up velocity about one third of the rate of increase in vault height arises from an increase in grip height and two thirds arises from an increase in push height.The athlete has a net energy gain during the vault. A faster run-up velocity produces a greater loss of energy during the take-off but this loss of energy is not sufficient to negate the increase in run-up velocity and the increase in the work done by the athlete during the pole support phase. PMID:24149197
Glazener, Cathryn; Constable, Lynda; Hemming, Christine; Breeman, Suzanne; Elders, Andrew; Cooper, Kevin; Freeman, Robert; Smith, Anthony R B; Hagen, Suzanne; McDonald, Alison; McPherson, Gladys; Montgomery, Isobel; Kilonzo, Mary; Boyers, Dwayne; Goulao, Beatriz; Norrie, John
2016-09-08
One in three women who have a prolapse operation will go on to have another operation, though not necessarily in the same compartment. Surgery can result in greater impairment of quality of life than the original prolapse itself (such as the development of new-onset urinary incontinence, or prolapse at a different site). Anterior and posterior prolapse surgery is most common (90 % of operations), but around 43 % of women also have a uterine (34 %) or vault (9 %) procedure at the same time. There is not enough evidence from randomised controlled trials (RCTs) to guide management of vault or uterine prolapse. The Vault or Uterine prolapse surgery Evaluation (VUE) study aims to assess the surgical management of upper compartment pelvic organ prolapse (POP) in terms of clinical effectiveness, cost-effectiveness and adverse events. VUE is two parallel, pragmatic, UK multicentre, RCTs (Uterine Trial and Vault Trial). Eligible for inclusion are women with vault or uterine prolapse: requiring a surgical procedure, suitable for randomisation and willing to be randomised. Randomisation will be computer-allocated separately for each trial, minimised on: requiring concomitant anterior and/or posterior POP surgery or not, concomitant incontinence surgery or not, age (under 60 years or 60 years and older) and surgeon. Participants will be randomly assigned, with equal probability to intervention or control arms in either the Uterine Trial or the Vault Trial. Uterine Trial participants will receive either a vaginal hysterectomy or a uterine preservation procedure. Vault Trial participants will receive either a vaginal sacrospinous fixation or an abdominal sacrocolpopexy. Participants will be followed up by postal questionnaires (6 months post surgery and 12 months post randomisation) and also reviewed in clinic 12 months post surgery. The primary outcome is the participant-reported Pelvic Organ Prolapse Symptom Score (POP-SS) at 12 months post randomisation. Demonstrating the efficacy of vault and uterine prolapse surgeries is relevant not only to patients and clinicians but also to health care providers, both in the UK and globally. Current controlled trials ISRCTN86784244 (assigned 19 October 2012), and the first subject was randomly assigned on 1 May 2013.
NASA Astrophysics Data System (ADS)
Maddin, Hillary C.; Piekarski, Nadine; Sefton, Elizabeth M.; Hanken, James
2016-08-01
Bones of the cranial vault appear to be highly conserved among tetrapod vertebrates. Moreover, bones identified with the same name are assumed to be evolutionarily homologous. However, recent developmental studies reveal a key difference in the embryonic origin of cranial vault bones between representatives of two amniote lineages, mammals and birds, thereby challenging this view. In the mouse, the frontal is derived from cranial neural crest (CNC) but the parietal is derived from mesoderm, placing the CNC-mesoderm boundary at the suture between these bones. In the chicken, this boundary is located within the frontal. This difference and related data have led several recent authors to suggest that bones of the avian cranial vault are misidentified and should be renamed. To elucidate this apparent conflict, we fate-mapped CNC and mesoderm in axolotl to reveal the contributions of these two embryonic cell populations to the cranial vault in a urodele amphibian. The CNC-mesoderm boundary in axolotl is located between the frontal and parietal bones, as in the mouse but unlike the chicken. If, however, the avian frontal is regarded instead as a fused frontal and parietal (i.e. frontoparietal) and the parietal as a postparietal, then the cranial vault of birds becomes developmentally and topologically congruent with those of urodeles and mammals. This alternative hypothesis of cranial vault homology is also phylogenetically consistent with data from the tetrapod fossil record, where frontal, parietal and postparietal bones are present in stem lineages of all extant taxa, including birds. It further implies that a postparietal may be present in most non-avian archosaurs, but fused to the parietal or supraoccipital as in many extant mammals.
Installing Electronics in Juno Vault
2010-12-16
Technicians install components that will aid with guidance, navigation and control of NASA Juno spacecraft. Like most of Juno sensitive electronics, these components are situated within the spacecraft titanium radiation vault.
Cutaway View of the Skylab Orbital Workshop
NASA Technical Reports Server (NTRS)
1973-01-01
This illustration is a cutaway view of a half of the Skylab Orbital Workshop (OWS) showing details of the living and working quarters. The OWS was divided into two major compartments. The lower level provided crew accommodations for sleeping, food preparation and consumption, hygiene, waste processing and disposal, and performance of certain experiments. The upper level consisted of a large work area and housed water storage tanks, a food freezer, storage vaults for film, scientific airlocks, mobility and stability experiment equipment, and other experimental equipment. The compartment below the crew quarters was a container for liquid and solid waste and trash accumulated throughout the mission. A solar array, consisting of two wings covered on one side with solar cells, was mounted outside the workshop to generate electrical power to augment the power generated by another solar array mounted on the solar observatory. Thrusters were provided at one end of the workshop for short-term control of the attitude of the space station.
Graefe, F.; Marschke, J.; Dimpfl, T.; Tunn, R.
2012-01-01
Vaginal vault suspension during hysterectomy for prolapse is both a therapy for apical insufficiency and helps prevent recurrence. Numerous techniques exist, with different anatomical results and differing complications. The description of the different approaches together with a description of the vaginal vault suspension technique used at the Department for Urogynaecology at St. Hedwig Hospital could serve as a basis for reassessment and for recommendations by scientific associations regarding general standards. PMID:25278621
Protecting Juno Electronics from Radiation
2010-07-12
Technicians installed the special radiation vault for NASA Juno spacecraft on the propulsion module. The radiation vault has titanium walls to protect the spacecraft electronic brain and heart from Jupiter harsh radiation environment.
Original blackandwhite print, VIEW OF UNFINISHED COURT AND VAULT ROOF ...
Original black-and-white print, VIEW OF UNFINISHED COURT AND VAULT ROOF AT ELEVENTH STREET - Internal Revenue Service Headquarters Building, 1111 Constitution Avenue Northwest, Washington, District of Columbia, DC
De Maio, Anna; Natale, Emiliana; Rotondo, Sergio; Di Cosmo, Anna; Faraone-Mennella, Maria Rosaria
2013-09-01
Our previous behavioural, biochemical and immunohistochemical analyses conducted in selected regions (supra/sub oesophageal masses) of the Octopus vulgaris brain detected a cytoplasmic poly-ADP-ribose polymerase (more than 90% of total enzyme activity). The protein was identified as the vault-free form of vault-poly-ADP-ribose polymerase. The present research extends and integrates the biochemical characterization of poly-ADP-ribosylation system, namely, reaction product, i.e., poly-ADP-ribose, and acceptor proteins, in the O. vulgaris brain. Immunochemical analyses evidenced that the sole poly-ADP-ribose acceptor was the octopus cytoskeleton 50-kDa actin. It was present in both free, endogenously poly-ADP-ribosylated form (70kDa) and in complex with V-poly-ADP-ribose polymerase and poly-ADP-ribose (260kDa). The components of this complex, alkali and high salt sensitive, were purified and characterized. The kind and the length of poly-ADP-ribose corresponded to linear chains of 30-35 ADP-ribose units, in accordance with the features of the polymer synthesized by the known vault-poly-ADP-ribose polymerase. In vitro experiments showed that V-poly-ADP-ribose polymerase activity of brain cytoplasmic fraction containing endogenous actin increased upon the addition of commercial actin and was highly reduced by ATP. Anti-actin immunoblot of the mixture in the presence and absence of ATP showed that the poly-ADP-ribosylation of octopus actin is a dynamic process balanced by the ATP-dependent polymerization of the cytoskeleton protein, a fundamental mechanism for synaptic plasticity. © 2013 Elsevier Inc. All rights reserved.
NORTH SIDE FACING TRACK, SHOWING ELECTRICAL BOX AND CONCRETE VAULT ...
NORTH SIDE FACING TRACK, SHOWING ELECTRICAL BOX AND CONCRETE VAULT - Edwards Air Force Base, South Base Sled Track, Electrical Distribution Station, South side of Sled Track, Lancaster, Los Angeles County, CA
Vault Area (original section), south corridor, looking west Fort ...
Vault Area (original section), south corridor, looking west - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC
CAA: Computer Assisted Athletics.
ERIC Educational Resources Information Center
Hall, John H.
Computers have been used in a variety of applications for athletics since the late 1950's. These have ranged from computer-controlled electric scoreboards to computer-designed pole vaulting poles. Described in this paper are a computer-based athletic injury reporting system and a computer-assisted football scouting system. The injury reporting…
Jiang, Janina; Liu, Guangchao; Kickhoefer, Valerie A; Rome, Leonard H; Li, Lin-Xi; McSorley, Stephen J; Kelly, Kathleen A
2017-01-19
Chlamydia trachomatis genital infection is the most common sexually transmitted bacterial disease, causing a significant burden to females due to reproductive dysfunction. Intensive screening and antibiotic treatment are unable to completely prevent female reproductive dysfunction, thus, efforts have become focused on developing a vaccine. A major impediment is identifying a safe and effective adjuvant which induces cluster of differentiation 4 (CD4) cells with attributes capable of halting genital infection and inflammation. Previously, we described a natural nanocapsule called the vault which was engineered to contain major outer membrane protein (MOMP) and was an effective vaccine which significantly reduced early infection and favored development of a cellular immune response in a mouse model. In the current study, we used another chlamydial antigen, a polymorphic membrane protein G-1 (PmpG) peptide, to track antigen-specific cells and evaluate, in depth, the vault vaccine for its protective capacity in the absence of an added adjuvant. We found PmpG-vault immunized mice significantly reduced the genital bacterial burden and histopathologic parameters of inflammation following a C. muridarum challenge. Immunization boosted antigen-specific CD4 cells with a multiple cytokine secretion pattern and reduced the number of inflammatory cells in the genital tract making the vault vaccine platform safe and effective for chlamydial genital infection. We conclude that vaccination with a Chlamydia -vault vaccine boosts antigen-specific immunities that are effective at eradicating infection and preventing reproductive tract inflammation.
Vaginal sacrospinous colpopexy and laparoscopic sacral colpopexy for vaginal vault prolapse.
Marcickiewicz, J; Kjöllesdal, M; Engh, M Ellström; Eklind, S; Axén, C; Brännström, M; Stjerndahl, J-H
2007-01-01
Vaginal sacrospinous colpopexy (VSC) and laparoscopic sacral colpopexy (LSC) both correct vault prolapse. The present study compares the perioperative course and long-term results of VSC and LSC. This retrospective study of post-hysterectomy vault prolapse involved 111 patients operated with either VSC (n=51) or LSC (n=60). The median time for the postoperative follow-up visit was 33.6 (range: 13-60) months for the LSC group and 38.4 (range: 7-108) months for the VSC group. Prolapse grade as well as the patient's satisfaction was recorded at the follow-up visit. Operation time was significantly shorter in the VSC group (median: 62 min) compared to the LSC group (median: 129 min). The rate of perioperative complications was low in both groups. There were 3 laparotomies in the LSC group, due to perioperative complications. The inpatients days were similar, with 3.7 days (1-18) and 4.0 days (2-21) in the VSC and the LSC group, respectively. Surgery for the recurrence of vault prolapse at any time before the follow-up visit did not occur in the VSC group, but occurred in 7 patients in the LSC group. At the follow-up visit, there was no recurrence of vault prolapse in either group. The subjective success rate was 82% in the VSC and 78% in the LSC group. This study indicates that VSC and LSC are two equally effective surgical procedures to correct vaginal vault prolapse, but the LSC technique requires a longer operating time.
Whole-body mathematical model for simulating intracranial pressure dynamics
NASA Technical Reports Server (NTRS)
Lakin, William D. (Inventor); Penar, Paul L. (Inventor); Stevens, Scott A. (Inventor); Tranmer, Bruce I. (Inventor)
2007-01-01
A whole-body mathematical model (10) for simulating intracranial pressure dynamics. In one embodiment, model (10) includes 17 interacting compartments, of which nine lie entirely outside of intracranial vault (14). Compartments (F) and (T) are defined to distinguish ventricular from extraventricular CSF. The vasculature of the intracranial system within cranial vault (14) is also subdivided into five compartments (A, C, P, V, and S, respectively) representing the intracranial arteries, capillaries, choroid plexus, veins, and venous sinus. The body's extracranial systemic vasculature is divided into six compartments (I, J, O, Z, D, and X, respectively) representing the arteries, capillaries, and veins of the central body and the lower body. Compartments (G) and (B) include tissue and the associated interstitial fluid in the intracranial and lower regions. Compartment (Y) is a composite involving the tissues, organs, and pulmonary circulation of the central body and compartment (M) represents the external environment.
Dynamic 3d Modeling of a Canal-Tunnel Using Photogrammetric and Bathymetric Data
NASA Astrophysics Data System (ADS)
Moisan, E.; Heinkele, C.; Charbonnier, P.; Foucher, P.; Grussenmeyer, P.; Guillemin, S.; Koehl, M.
2017-02-01
This contribution introduces an original method for dynamically surveying the vault and underwater parts of a canal-tunnel for 3D modeling. The recording system, embedded on a barge, is composed of cameras that provide images of the above-water part of the tunnel, and a sonar that acquires underwater 3D profiles. In this contribution we propose to fully exploit the capacities of photogrammetry to deal with the issue of geo-referencing data in the absence of global positioning system (GPS) data. More specifically, we use it both for reconstructing the vault and side walls of the tunnel in 3D and for estimating the trajectory of the boat, which is necessary to rearrange sonar profiles to form the 3D model of the canal. We report on a first experimentation carried out inside a canal-tunnel and show promising preliminary results that illustrate the potentialities of the proposed approach.
NASA Astrophysics Data System (ADS)
Chintzoglou, G.; De Pontieu, B.; Martinez-Sykora, J.; Mendes Domingos Pereira, T.; Vourlidas, A.; Tun Beltran, S.
2017-12-01
We present the analysis of data from the observing campaign in support to the VAULT2.0 sounding rocket launch on September 30, 2014. VAULT2.0 is a Lyα (1216 Å) spectroheliograph capable of providing fast cadence spectroheliograms of high-spectral purity. High resolution Lyα observations are highly complementary with the IRIS observations of the upper chromosphere and the low transition region but have previously been unavailable. The VAULT2.0 data provide critical, new upper-chromospheric constraints for numerical models. The observing campaign was closely coordinated with the IRIS mission. Taking advantage of this simultaneous multi-wavelength coverage of target AR 12172 and by using state-of-the-art radiative-MHD simulations of spicules, we are able to perform a detailed investigation of a type-II spicule associated with a fast apparent network jet recorded in the campaign observations during the VAULT2.0 flight. Our unique analysis suggests that spicular material exists suspended in lower temperatures until it rapidly gets heated and becomes visible in transition-region temperatures as an apparent network jet.
19. INTERIOR: ARCH AND CORBELED VAULT NEAR FRONT Copy photograph ...
19. INTERIOR: ARCH AND CORBELED VAULT NEAR FRONT Copy photograph of photogrammetric plate LC-HABS-GS07-1116-113L. - Provident Life & Trust Company Bank, 407-409 Chestnut Street, Philadelphia, Philadelphia County, PA
Installing Juno Radiation Vault
2010-07-12
Technicians installed a special radiation vault onto the propulsion module of NASA Juno spacecraft. Each titanium wall measures nearly a square meter nearly 10 square feet in area and about 1 centimeter a third of an inch in thickness.
The Carnegie Quick Deploy Box (QDB) for use with broadband and intermediate period sensors
NASA Astrophysics Data System (ADS)
Wagner, L. S.; Roman, D.; Bartholomew, T.; Golden, S.; Schleigh, B.
2017-12-01
Recent data processing advances have increased the call for dense recordings of teleseismic data. However, traditional broadband field installations typically comprise 1) a sensor vault 2) a field box to hold the recording and power systems, and 3) a solar panel mount. The construction of these installations is time consuming and requires bulky construction materials, limiting the number of stations that can be installed from a single vehicle without repeated trips to a storage facility. Depending on the deployment location, watertight containers for both vault and field box can be difficult to find, resulting in a loss of data due to flooding. Recent technological improvements have made possible the direct burial of sensors (no vault required) and a reduction in the size of the solar panels needed to run a station. With support from the Brinson Foundation, we take advantage of these advances to create a field box/shipping container that will greatly simplify these types of seismic deployments. The goal of the Carnegie Quick Deploy Box (QDB) is to have everything needed for an intermediate period station install (except battery and shovel) contained in a single box for shipment, and to be able to leave everything (except the shovel) in that box when the station is deployed. The box is small enough ( 13"x13"x21") and lightweight enough (< 35 lbs) to be checked as airline luggage. The solar panel mount can be attached securely to the top of the box, but it can also be pole mounted with U-bolts or hose clamps. The sensor can be direct-buried. The sensor cable and solar panel cable plug into watertight bulkhead-fitted plugs on the outside of the box that are in turn plugged into the digitizer and power regulator inside the box. Our prototype boxes (Pelican Cases) have proved watertight when submerged for days. This equipment has been tested in Alaska in winter and Nicaragua in summer without failure due to flooding or power. The cost for parts for a single box (not including sensor cable, sensor, or digitizer) is $500. The setup is simple, and can be completed in a matter of minutes once the sensor is installed. QDBs such as ours will make possible a dramatic increase in the number of stations that can be installed, while also significantly decreasing the cost of deployment per station by reducing vehicle time, fuel, personnel time, and shipping costs.
Triangular Resection of the Upper Lateral Cartilage for Middle Vault Deviation.
Ryu, Gwanghui; Seo, Min Young; Lee, Kyung Eun; Hong, Sang Duk; Chung, Seung-Kyu; Dhong, Hun-Jong; Kim, Hyo Yeol
2018-06-02
Middle vault deviation has a significant effect on the aesthetic and functional aspects of the nose, and its management continues to be a challenge. Spreader graft and its modification techniques have been focused, but there has been scarce consideration for removing surplus portion and balancing the upper lateral cartilage (ULC). This study aimed to report the newly invented triangular-shaped resection technique ("triangular resection") of the ULC and to evaluate its efficacy for correcting middle vault deviation. A retrospective study included 17 consecutive patients who presented with middle vault deviation and underwent septorhinoplasty by using triangular resection at a tertiary academic hospital from February 2014 and March 2016. Their outcomes were evaluated pre- and postoperatively including medical photographs, acoustic rhinometry and subjective nasal obstruction using a 7-point Likert scale. The immediate outcomes were evaluated around 1 month after surgery, and long-term outcomes were available in 12 patients; the mean follow-up period was 9.1 months. Nasal tip deviation angle was reduced from 5.66º to 2.37º immediately (P<0.001). Middle vault deviation also improved from 169.50º to 177.24º (P<0.001). Long-term results were 2.49º (P=0.015) for nasal tip deviation and 178.68º (P=0.002) for middle vault deviation. The aesthetic outcome involved a complete correction in eight patients (47.1%), a minimally visible deviation in seven patients (41.2%) and a remaining residual deviation in two patients (11.8%). Pre- and postoperative minimal cross-sectional areas (summation of the right and left sides) were 0.86 and 1.07, respectively (P=0.021). Fifteen patients answered about their nasal obstruction symptoms and the median symptom score had alleviated from 6.0 to 3.0 (P=0.004). Triangular resection of the ULC is a simple and effective method for correcting middle vault deviation and balancing the ULCs without complications as internal nasal valve narrowing.
Detail of Bright Angel stone vault, containing condenser, Hoffman condensation ...
Detail of Bright Angel stone vault, containing condenser, Hoffman condensation pump, Jennings vacuum heating pump, and misc. pipes and valves. - Grand Canyon Village Utilities, Grand Canyon National Park, Grand Canyon Village, Coconino County, AZ
Numerical and experimental analysis of an in-scale masonry cross-vault prototype up to failure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rossi, Michela; Calderini, Chiara; Lagomarsino, Sergio
2015-12-31
A heterogeneous full 3D non-linear FE approach is validated against experimental results obtained on an in-scale masonry cross vault assembled with dry joints, and subjected to various loading conditions consisting on imposed displacement combinations to the abutments. The FE model relies into a discretization of the blocks by means of few rigid-infinitely resistant parallelepiped elements interacting by means of planar four-noded interfaces, where all the deformation (elastic and inelastic) occurs. The investigated response mechanisms of vault are the shear in-plane distortion and the longitudinal opening and closing mechanism at the abutments. After the validation of the approach on the experimentallymore » tested cross-vault, a sensitivity analysis is conducted on the same geometry, but in real scale, varying mortar joints mechanical properties, in order to furnish useful hints for safety assessment, especially in presence of seismic action.« less
An unusual cause of vaginal discharge following gender reassignment.
Sukumaran, S; Moran, P A; Makar, A
2009-02-01
Neovaginal reconstruction is an important part of gender reassignment surgery. We report a case of stone formation at the apex of vaginal vault constructed with sigmoid colon segment. A 48-year-old woman presented with profuse vaginal discharge for 1 year. She had a history of gender reassignment surgery (male to female) in 1994, and the neovagina had been constructed with an isolated sigmoid colon. Vaginoscopy performed using a cystoscope revealed multiple calculi at the vaginal vault on the endoscopic gastrointestinal anastomosis staples that had been used to close the vault. Colon-vaginoplasty has the advantages of providing adequate lubrication, but excessive vaginal discharge could be a problem, as colon is a mucous membrane. Stone formation in the vaginal vault should be considered in cases of gender reassignment with persistent vaginal discharge. This case also highlights the use of cystoscope in visualising the upper vagina in difficult circumstances.
9. Interior of Building 1001 (administration building), Room 204, vault, ...
9. Interior of Building 1001 (administration building), Room 204, vault, looking east - Naval Air Station Chase Field, Building 1001, Independence Street, .45 mile south of intersection of Texas State Highway & Independence Street, Beeville, Bee County, TX
Detail of northeast stair entry with vaulted stair landing and ...
Detail of northeast stair entry with vaulted stair landing and ghost of former stair arch below stepped rail, facing west. - Marine Barracks, Panama Canal, Barracks Building, 100' North of Thatcher Highway, Balboa, Former Panama Canal Zone, CZ
2. GENERAL VIEW OF INTERIOR. NOTE SKYLIGHTS ON VAULTED CEILING. ...
2. GENERAL VIEW OF INTERIOR. NOTE SKYLIGHTS ON VAULTED CEILING. Photocopy of circa 1910 photo published in a 1911 book, Stanley's Views of Philadelphia. - Pennsylvania Company for Insurances on Lives & Granting Annuities, 431 Chestnut Street, Philadelphia, Philadelphia County, PA
1. Photocopy of July 13, 1959 photograph, courtesy of Committee ...
1. Photocopy of July 13, 1959 photograph, courtesy of Committee of Public Property, Philadelphia, Pennsylvania. VIEW OF VAULTS (on sidewalk), LOOKING EAST TOWARD FRONT STREET - Granite Street Vaults, 100-112 & 101-127 Granite Street, Philadelphia, Philadelphia County, PA
Particle image velocimetry of a flow at a vaulted wall.
Kertzscher, U; Berthe, A; Goubergrits, L; Affeld, K
2008-05-01
The assessment of flow along a vaulted wall (with two main finite radii of curvature) is of general interest; in biofluid mechanics, it is of special interest. Unlike the geometry of flows in engineering, flow geometry in nature is often determined by vaulted walls. Specifically the flow adjacent to the wall of blood vessels is particularly interesting since this is where either thrombi are formed or atherosclerosis develops. Current measurement methods have problems assessing the flow along vaulted walls. In contrast with conventional particle image velocimetry (PIV), this new method, called wall PIV, allows the investigation of a flow adjacent to transparent flexible surfaces with two finite radii of curvature. Using an optical method which allows the observation of particles up to a predefined depth enables the visualization solely of the boundary layer flow. This is accomplished by adding a specific dye to the fluid which absorbs the monochromatic light used to illuminate the region of observation. The obtained images can be analysed with the methods of conventional PIV and result in a vector field of the velocities along the wall. With wall PIV, the steady flow adjacent to the vaulted wall of a blood pump was investigated and the resulting velocity field as well as the velocity fluctuations were assessed.
7. Photocopy of Elevations drawing (from the BPA Engineering Vault, ...
7. Photocopy of Elevations drawing (from the BPA Engineering Vault, Drawing C13-J2-342-D1, Sheet 3, 13 March 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR
2. Photocopy of July 13, 1959 photograph, courtesy of Committee ...
2. Photocopy of July 13, 1959 photograph, courtesy of Committee of Public Property, Philadelphia, Pennsylvania. VIEW OF VAULTS, LOOKING WEST TOWARD CORNER OF GRANITE AND DOCK STREETS - Granite Street Vaults, 100-112 & 101-127 Granite Street, Philadelphia, Philadelphia County, PA
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Vault. 910.70 Section 910.70 Parks, Forests, and Public Property PENNSYLVANIA AVENUE DEVELOPMENT CORPORATION GENERAL GUIDELINES AND UNIFORM STANDARDS FOR URBAN PLANNING AND DESIGN OF DEVELOPMENT WITHIN THE PENNSYLVANIA AVENUE DEVELOPMENT...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Vault. 910.70 Section 910.70 Parks, Forests, and Public Property PENNSYLVANIA AVENUE DEVELOPMENT CORPORATION GENERAL GUIDELINES AND UNIFORM STANDARDS FOR URBAN PLANNING AND DESIGN OF DEVELOPMENT WITHIN THE PENNSYLVANIA AVENUE DEVELOPMENT...
NASA Juno Spacecraft Taking Shape in Denver
2011-03-07
This image shows NASA Juno spacecraft undergoing environmental testing at Lockheed Martin Space Systems on Jan. 26, 2011. All 3 solar array wings are installed and stowed, and the large high-gain antenna is in place on the top of the avionics vault.
Verification testing of the Practical Best Management, Inc., CrystalStream™ stormwater treatment system was conducted over a 15-month period starting in March, 2003. The system was installed in a test site in Griffin, Georgia, and served a drainage basin of approximately 4 ...
Zhang, Wei; Neo, Suat Peng; Gunaratne, Jayantha; Poulsen, Anders; Boping, Liu; Ong, Esther Hongqian; Sangthongpitag, Kanda; Pendharkar, Vishal; Hill, Jeffrey; Cohen, Stephen M
2015-03-01
The high proliferation rate of cancer cells, together with environmental factors such as hypoxia and nutrient deprivation can cause Endoplasmic Reticulum (ER) stress. The protein kinase PERK is an essential mediator in one of the three ER stress response pathways. Genetic and pharmacological inhibition of PERK has been reported to limit tumor growth in xenograft models. Here we provide evidence that inactive PERK interacts with the nuclear pore-associated Vault complex protein and that this compromises Vault-mediated nuclear transport of PTEN. Pharmacological inhibition of PERK under ER stress results is abnormal sequestration of the Vault complex, leading to increased cytoplasmic PTEN activity and lower AKT activation. As the PI3K/PTEN/AKT pathway is crucial for many aspects of cell growth and survival, this unexpected effect of PERK inhibitors on AKT activity may have implications for their potential use as therapeutic agents. Copyright © 2014. Published by Elsevier Inc.
Harvey Cushing's Approaches to Tumors in His Early Career: From the Skull Base to the Cranial Vault
Pendleton, Courtney; Raza, Shaan M.; Gallia, Gary L.; Quiñones-Hinojosa, Alfredo
2011-01-01
In this report, we review Dr. Cushing's early surgical cases at the Johns Hopkins Hospital, revealing details of his early operative approaches to tumors of the skull base and cranial vault. Following Institutional Review Board approval, and through the courtesy of the Alan Mason Chesney Archives, we reviewed the Johns Hopkins Hospital surgical files from 1896 to 1912. Participants included four adult patients and one child who underwent surgical resection of bony tumors of the skull base and the cranial vault. The main outcome measures were operative approach and condition recorded at the time of discharge. The indications for surgery included unspecified malignant tumor of the basal meninges and temporal bone, basal cell carcinoma, osteoma of the posterior skull base, and osteomas of the frontal and parietofrontal cranial vault. While Cushing's experience with selected skull base pathology has been previously reported, the breadth of his contributions to operative approaches to the skull base has been neglected. PMID:22470271
NASA Astrophysics Data System (ADS)
Sweet, J. R.; Beaudoin, B. C.; Barstow, N.; Pfeifer, M.; Anderson, K. R.; Frassetto, A.
2015-12-01
Advances in seismometer design have diversified the range of instruments available for use in temporary field installations. IRIS programs, primarily PASSCAL and the Transportable Array (TA), have helped steer development of these new instruments to meet these evolving needs. PASSCAL operates a small pool of posthole broadband sensors, purpose built for direct burial. Near surface posthole installations are a new, cost effective, and logistically simple technique for broadband emplacement that is an alternative to the vault installations used in portable broadband seismic experiments for nearly 30 years. Direct burial installation is limited to the time and effort required to dig the borehole and emplace the sensor, thus reducing both material costs and time to install. Also, in Alaska, extreme environments and difficult logistics make standard TA tank vaults inappropriate for most sites. TA has developed improved deployment strategies for these environments. There, holes for posthole sensors are hammer- drilled or augered to several meters depth in soil, permafrost, or bedrock and then cased. These emplacement costs are generally less than standard TA vaults. We compare various installation techniques for test cases as well as general deployments of PASSCAL and TA stations. Automated noise performance analyses have been part of the TA throughout its operation, but until recently vault performance for portable installations supported by the PASSCAL program was sparse. In this study, we select a suite of co-located direct burial and surface vault installations and compare their noise performance using probability density functions. Our initial analyses suggest that direct burial sensors have lower noise levels than vault installations on both horizontal and vertical channels across a range of periods spanning <1 s to 100 s. However, most of these initial experiments for PASSCAL were with sensors not purpose built for direct burial and it became obvious that a sensor designed for direct burial was necessary. For the TA, direct emplacement of purpose-built sensors has routinely improved noise levels, particularly beyond about 20 s, by tens of dB. These results suggest that moving towards an instrument pool composed primarily of purpose-built direct burial sensors could yield higher-quality data at lower cost.
Survival of Ascaris eggs and hygienic quality of human excreta in Vietnamese composting latrines.
Jensen, Peter K M; Phuc, Pham D; Konradsen, Flemming; Klank, Lise T; Dalsgaard, Anders
2009-12-16
For centuries farmers in Vietnam have fertilized their fields with human excreta collected directly from their household latrines. Contrary to the official guideline of six-month storage, the households usually only store human excreta for three to four months before use, since this is the length of time that farmers have available to produce fertilizer between two cropping seasons. This study aimed to investigate whether hygienically safe fertilizer could be produced in the latrines within this period of time. By inoculating eggs of the helminth parasite indicator Ascaris suum into heaps of human excreta, a die-off experiment was conducted under conditions similar to those commonly used in Vietnamese latrines. Half a ton of human excreta was divided into five heaps containing increasing concentrations of lime from 0% to 11%. Regardless of the starting pH, which varied from 9.4 to 11.6, a >99% die-off of eggs was obtained after 105 to 117 days of storage for all lime concentrations and 97% of eggs were non-viable after 88 days of storage. The most critical parameter found to determine the die-off process was the amount of ammonia (urine) in the excreta which indicates that longer storage periods are needed for parasite egg die-off if urine is separated from the excreta. By inactivating >99% of all A. suum eggs in human excreta during a storage period of only three months the commonly used Double Vault Composting (DVC) latrine, in which urine is not separated, could therefore potentially provide a hygienic acceptable fertilizer.
Palmprint Based Multidimensional Fuzzy Vault Scheme
Liu, Hailun; Sun, Dongmei; Xiong, Ke; Qiu, Zhengding
2014-01-01
Fuzzy vault scheme (FVS) is one of the most popular biometric cryptosystems for biometric template protection. However, error correcting code (ECC) proposed in FVS is not appropriate to deal with real-valued biometric intraclass variances. In this paper, we propose a multidimensional fuzzy vault scheme (MDFVS) in which a general subspace error-tolerant mechanism is designed and embedded into FVS to handle intraclass variances. Palmprint is one of the most important biometrics; to protect palmprint templates; a palmprint based MDFVS implementation is also presented. Experimental results show that the proposed scheme not only can deal with intraclass variances effectively but also could maintain the accuracy and meanwhile enhance security. PMID:24892094
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collard, L.B.
2000-09-26
This revision was prepared to address comments from DOE-SR that arose following publication of revision 0. This Special Analysis (SA) addresses disposal of wastes with high concentrations of I-129 in the Intermediate-Level (IL) Vaults at the operating, low-level radioactive waste disposal facility (the E-Area Low-Level Waste Facility or LLWF) on the Savannah River Site (SRS). This SA provides limits for disposal in the IL Vaults of high-concentration I-129 wastes, including activated carbon beds from the Effluent Treatment Facility (ETF), based on their measured, waste-specific Kds.
Estimating Bird / Aircraft Collision Probabilities and Risk Utilizing Spatial Poisson Processes
2012-06-10
Operations (1995-2011) ........................................... 2 Table 2 DeVault Top 15 Relative Hazard Score...dedicated bird radar (Dokter, et al. 2011). The WRS-88D is used in the Avian Hazard Advisory System which is described later in this paper. Advisory...Avian Hazard Advisory System (AHAS) is an online, near real-time, geographic information system (GIS) used for bird strike risk flight planning across
Simulation and testing of pyramid and barrel vault skylights
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGowan, A.G.; Desjarlais, A.O.; Wright, J.L.
1998-10-01
The thermal performance of fenestration in commercial buildings can have a significant effect on building loads--yet there is little information on the performance of these products. With this in mind, ASHRAE TC 4.5, Fenestration, commissioned a research project involving test and simulation of commercial fenestration systems. The objectives of ASHRAE Research Project 877 were: to evaluate the thermal performance (U-factors) of commonly used commercial glazed roof and wall assemblies; to obtain a better fundamental understanding of the heat transfer processes that occur in these specialty fenestration products; to develop correlations for natural-convection heat transfer in complex glazing cavities; to developmore » a methodology for evaluating complex fenestration products, suitable for inclusion in ASHRAE Standard 142P (ASHRAE 1996); and to generate U-factors for common commercial fenestration products, suitable for inclusion in the ASHRAE Handbook--Fundamentals. This paper describes testing and simulation of pyramid and barrel vault skylight specimens and provides guidelines for modeling these systems based on the validated results.« less
3. Photocopy of July 13, 1959 photograph, courtesy of Committee ...
3. Photocopy of July 13, 1959 photograph, courtesy of Committee of Public Property, Philadelphia, Pennsylvania. VIEW OF UNDERGROUND VAULT WITH GRANITE CEILING AND RUBBLE WALL. NOTE ARCH AT RIGHT SIDE OF PHOTO - Granite Street Vaults, 100-112 & 101-127 Granite Street, Philadelphia, Philadelphia County, PA
ERIC Educational Resources Information Center
Griffitts, Dawn
2001-01-01
This "Inside the Vault" newsletter contains two issues. Issue 1 contains a lead article, "Reading the Fed's Playbook," a question-and-answer section, and a bulletin board. The Federal Reserve's primary mission is to ensure that enough money and credit are available to sustain economic growth without inflation. The article…
Dua, A; Galimberti, A; Subramaniam, M; Popli, G; Radley, S
2012-02-01
To evaluate the efficacy of vault drainage in reducing the immediate postoperative morbidity associated with vaginal hysterectomy carried out for benign gynaecological conditions. Randomised controlled trial. A tertiary referral gynaecology centre in UK. A total of 272 women who underwent vaginal hysterectomy for benign conditions between March 2005 and June 2010. The 272 women were randomised to have a drain inserted or not inserted, 'drain' or 'no drain', respectively, before vault closure during vaginal hysterectomy, using a sealed envelope technique. The surgical procedures were performed using the surgeons' standard technique and postoperative care was delivered according to the unit's protocol. The primary outcome measure was reduction in postoperative febrile morbidity. Secondary outcome measures were hospital readmission rate, blood transfusion, change in postoperative haemoglobin and length of stay. In all, 135 women were randomised to have a drain and 137 to 'no drain'. There were no differences in the incidence of febrile morbidity, length of stay, change in haemoglobin or need for postoperative blood transfusion between the two groups. The routine use of vault drain at vaginal hysterectomy for benign disorders has no significant effect on postoperative morbidity. The use of vault drain in this context is not recommended. © 2011 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2011 RCOG.
Field Test of a Three-Channel Seismic Event Discriminator
1975-03-01
vault contains three corner piers, in addition to the primary central pier. Using the corner piers, a pair of 19-foot long-period mercury tiltmeters ...seismometers were the sensors used in testing the seismic event- discriminator system. The recording equipment consisted of an eight- channel pressure
Code of Federal Regulations, 2014 CFR
2014-04-01
... available upon demand for each day, shift, and drop cycle (this is not required if the system does not track..., beverage containers, etc., into and out of the cage. (j) Variances. The operation must establish, as...
Code of Federal Regulations, 2013 CFR
2013-04-01
... available upon demand for each day, shift, and drop cycle (this is not required if the system does not track..., beverage containers, etc., into and out of the cage. (j) Variances. The operation must establish, as...
Functional anatomy of the nasal bones and adjacent structures. Consequences for nasal surgery.
Popko, M; Verlinde-Schellekens, S A M W; Huizing, E H; Bleys, R L A W
2018-03-01
The periosteum of the nasal bones, the periosteal-perichondrial nasal envelope, and the cartilaginous support of the bony vault were studied in serial coronal sections of four human cadaver noses. To differentiate between the various tissue components, the sections were stained according to Mallory-Cason and Verhoeff-Van Gieson stain. The results demonstrated: 1. the presence of clearly distinguishable layers of the periosteum covering the nasal bones; 2. the presence of a continuous periosteal-perichondrial covering of the bony and cartilaginous nasal vaults; 3. the way the cartilaginous support of the bony vault is constructed. The findings described in the present study may have clinical relevance in nasal surgery.
LoPresti, Melissa; Daniels, Bradley; Buchanan, Edward P; Monson, Laura; Lam, Sandi
2017-04-01
Repeat surgery for restenosis after initial nonsyndromic craniosynostosis intervention is sometimes needed. Calvarial vault reconstruction through a healed surgical bed adds a level of intraoperative complexity and may benefit from preoperative and intraoperative definitions of biometric and aesthetic norms. Computer-assisted design and manufacturing using 3D imaging allows the precise formulation of operative plans in anticipation of surgical intervention. 3D printing turns virtual plans into anatomical replicas, templates, or customized implants by using a variety of materials. The authors present a technical note illustrating the use of this technology: a repeat calvarial vault reconstruction that was planned and executed using computer-assisted design and 3D printed intraoperative guides.
NASA Astrophysics Data System (ADS)
Espinosa Duran, John Michael
The study of nanosystems and their emergent properties requires the development of multiscale computational models, theories and methods that preserve atomic and femtosecond resolution, to reveal details that cannot be resolved experimentally today. Considering this, three long time scale phenomena were studied using molecular dynamics and multiscale methods: self-assembly of organic molecules on graphite, energy transfer in nanosystems, and structural transition in vault nanoparticles. Molecular dynamics simulations of the self-assembly of alkoxybenzonitriles with different tail lengths on graphite were performed to learn about intermolecular interactions and phases exhibited by self-organized materials. This is important for the design of ordered self-assembled organic photovoltaic materials with greater efficiency than the disordered blends. Simulations revealed surface dynamical behaviors that cannot be resolved experimentally today due to the lack of spatiotemporal resolution. Atom-resolved structures predicted by simulations agreed with scanning tunneling microscopy images and unit cell measurements. Then, a multiscale theory based on the energy density as a field variable is developed to study energy transfer in nanoscale systems. For applications like photothermal microscopy or cancer phototherapy is required to understand how the energy is transferred to/from nanosystems. This multiscale theory could be applied in this context and here is tested for cubic nanoparticles immersed in water for energy being transferred to/from the nanoparticle. The theory predicts the energy transfer dynamics and reveals phenomena that cannot be described by current phenomenological theories. Finally, temperature-triggered structural transitions were revealed for vault nanoparticles using molecular dynamics and multiscale simulations. Vault is a football-shaped supramolecular assembly very distinct from the commonly observed icosahedral viruses. It has very promising applications in drug delivery and has been extensively studied experimentally. Sub-microsecond multiscale simulations at 310 K on the vault revealed the opening and closing of fractures near the shoulder while preserving the overall structure. This fracture mechanism could explain the uptake and release of small drugs while maintaining the overall structure. Higher temperature simulations show the generation of large fractures near the waist, which enables interaction of the external medium with the inner vault residues. Simulation results agreed with microscopy and spectroscopy measurements, and revealed new structures and mechanisms.
Surgery: Modified Pi with Triple-Bonnet Flap and Fronto-Orbital Advancement.
Singh Raswan, Uday; Singh Chhiber, Sarbjit; Ramzan, Altaf Umar
2017-01-01
Craniosynostosis is the premature fusion of one or more of the cranial sutures and can occur as part of a syndrome or as an isolated defect. Pansynostosis is a rare form of craniosynostosis that involves premature fusion of all the cranial sutures (coronal, sagittal, metopic, and occipital). Particularly in cases of late presentation, there are heightened clinical concerns, both functional and aesthetic. In untreated cases of pansynostosis and increased intracranial pressure, optic nerve damage progresses to optic atrophy and then blindness. Cranial vault reconstruction is the standard surgical treatment. We attempt to highlight the importance of modifying the osteotomies and reshaping of the cranial vault based on individual requirements in order to achieve the best possible result and to prevent catastrophic blood loss. We present a case of modified pi with triple-bonnet flap and fronto-orbital advancement, an individual modification of the techniques of cranial vault reconstruction, in a patient with pansynostosis with optic atrophy. The technical variation can be applied to any case of pansynostosis requiring cranial vault reconstruction. © 2017 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Vourlidas, Angelos; Beltran, Samuel Tun; Chintzoglou, Georgios; Eisenhower, Kevin; Korendyke, Clarence; Feldman, Ronen; Moser, John; Shea, John; Johnson-Rambert, Mary; McMullin, Don; Stenborg, Guillermo; Shepler, Ed; Roberts, David
2016-03-01
Very high angular resolution ultraviolet telescope (VAULT2.0) is a Lyman-alpha (Lyα; 1216Å) spectroheliograph designed to observe the upper chromospheric region of the solar atmosphere with high spatial (<0.5‧‧) and temporal (8s) resolution. Besides being the brightest line in the solar spectrum, Lyα emission arises at the temperature interface between coronal and chromospheric plasmas and may, hence, hold important clues about the transfer of mass and energy to the solar corona. VAULT2.0 is an upgrade of the previously flown VAULT rocket and was launched successfully on September 30, 2014 from White Sands Missile Range (WSMR). The target was AR12172 midway toward the southwestern limb. We obtained 33 images at 8s cadence at arc second resolution due to hardware problems. The science campaign was a resounding success, with all space and ground-based instruments obtaining high-resolution data at the same location within the AR. We discuss the science rationale, instrument upgrades, and performance during the first flight and present some preliminary science results.
Markiewicz, Michael R; Alden, Tord; Momin, Mohmed Vasim; Olsson, Alexis B; Jurado, Ray J; Abdullah, Fizan; Miloro, Michael
2017-08-01
Recent interventions have aimed at reducing the need for blood transfusions in the perioperative period in patients with craniosynostosis undergoing cranial vault remodeling. However, little is known regarding whether the receipt of a blood transfusion influences the length of hospital stay. The purpose of this study was to assess whether the receipt of a blood transfusion in patients undergoing cranial vault remodeling is associated with an increased length of stay. To address the research purposes, we designed a retrospective cohort study using the 2014 Pediatric National Surgical Quality Improvement Program (NSQIP Peds) dataset. The primary predictor variable was whether patients received a blood transfusion during cranial vault remodeling. The primary outcome variable was length of hospital stay after the operation. The association between the receipt of blood transfusions and length of stay was assessed using the Student t test. The association between other covariates and the outcome variable was assessed using linear regression, analysis of variance, and the Tukey test for post hoc pair-wise comparisons. The sample was composed of 756 patients who underwent cranial vault remodeling: 503 who received blood transfusions and 253 who did not. The primary predictor variable of blood transfusion was associated with an increased length of stay (4.1 days vs 3.0 days, P = .03). Other covariates associated with an increased length of stay included race, American Society of Anesthesiologists status, premature birth, presence of a congenital malformation, and number of sutures involved in craniosynostosis. The receipt of a blood transfusion in the perioperative period in patients with craniosynostosis undergoing cranial vault remodeling was associated with an increased length of stay. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Fujibuchi, Toshioh; Nohtomi, Akihiro; Baba, Shingo; Sasaki, Masayuki; Komiya, Isao; Umedzu, Yoshiyuki; Honda, Hiroshi
2015-01-01
Compact medical cyclotrons have been set up to generate the nuclides necessary for positron emission tomography. In accelerator facilities, neutrons activate the concrete used to construct the vault room; this activation increases with the use of an accelerator. The activation causes a substantial radioactive waste management problem when facilities are decommissioned. In the present study, several concrete cores from the walls, ceiling and floor of a compact medical cyclotron vault room were samples 2 years after the termination of operations, and the radioactivity concentrations of radionuclides were estimated. Cylindrical concrete cores 5 cm in diameter and 10 cm in length were bored from the concrete wall, ceiling and floor. Core boring was performed at 18 points. The gamma-ray spectrum of each sample was measured using a high-purity germanium detector. The degree of activation of the concrete in the cyclotron vault room was analyzed, and the range and tendency toward activation in the vault room were examined. (60)Co and (152)Eu were identified by gamma-ray spectrometry of the concrete samples. (152)Eu and (60)Co are produced principally from the stable isotopes of europium and cobalt by neutron capture reactions. The radioactivity concentration did not vary much between the surface of the concrete and at a depth of 10 cm. Although the radioactivity concentration near the target was higher than the clearance level for radioactive waste indicated in IAEA RS-G-1.7, the mean radioactivity concentration in the walls and floor was lower than the clearance level. The radioactivity concentration of the inner concrete wall of the medical cyclotron vault room was not uniform. The areas exceeding the clearance level were in the vicinity of the target, but most of the building did not exceed the clearance levels.
Balzeau, Antoine
2013-06-01
Homo erectus sensu lato (s.l.) is a key species in the hominin fossil record for the study of human evolution, being one of the first species discovered and perhaps the most documented, but also because of its long temporal range and having dispersed out of Africa earlier than any other human species. Here I test two proposed autapomorphic traits of H. erectus, namely the increased thickness of the upper cranial vault and parasagittal keeling. The definition of these two anatomical features and their expression and variation among hominids are discussed. The results of this study indicate that the upper vault in Asian H. erectus is not absolutely thicker compared with fossil anatomically modern Homo sapiens, whereas Broken Hill and Petralona have values above the range of variation of H. erectus. Moreover, this anatomical region in Asian H. erectus is not significantly thicker compared with Pan paniscus. In addition, these results demonstrate that cranial vault thickness should not be used to make hypotheses regarding sexual attribution of fossil hominin specimens. I also show that the relation between relief on the external surface of the upper vault, parasagittal keeling and bregmatic eminence, and bone thickness is complex. In this context, the autapomorphic status of the two analysed traits in H. erectus may be rejected. Nevertheless, different patterns in the distribution of bone thickness on the upper vault were identified. Some individual variations are visible, but specificities are observable in samples of different species. The pattern of bone thickness distribution observed in Asian H. erectus, P. paniscus, possibly australopiths, and early Homo or Homo ergaster/erectus appears to be shared by these different species and would be a plesiomorphic trait among hominids. In contrast, two apomorphic states for this feature were identified for Neandertals and H. sapiens. Copyright © 2013 Elsevier Ltd. All rights reserved.
SU-E-T-90: Concrete Forward-Scatter Fractions for Radiotherapy Shielding Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanny, S; Parsai, E
2014-06-01
Purpose: There is little instruction within the primary shielding guidance document NCRP 151 for vault designs where the primary beam intercepts the maze. We have conducted a Monte-Carlo study to characterize forward-scattered radiation from concrete barriers with the intent of quantifying what amount of additional shielding outside the primary beam is needed in this situation. Methods: We reproduced our vault in MCNP 5 and simulated spectra obtained from the literature and from our treatment planning system for 10 and 18 MV beams. Neutron and gamma-capture contributions were not simulated. Energy deposited was scored at isocenter in a water phantom, withinmore » various cells that comprised the maze, and within cells that comprised the vault door. Tracks were flagged that scattered from within the maze to the door and their contributions were tallied separately. Three different concrete mixtures found in the literature were simulated. An empirically derived analytic equation was used for comparison, utilizing patient scatter fractions to approximate the scatter from concrete. Results: Our simulated data confirms that maze-scattered radiation is a significant contribution to total photon dose at the door. It contributes between 20-35% of the photon shielding workload. Forward-scatter fractions for concrete were somewhat dependent on concrete composition and the relative abundance of higher-Z elements. Scatter fractions were relatively insensitive to changes in the primary photon spectrum. Analytic results were of the same magnitude as simulated results. Conclusions: Forward-scattered radiation from the maze barrier needs to be included in the photon workload for shielding calculations in non-standard vault designs. Scatter fractions will vary with concrete composition, but should be insensitive to spectral changes between machine manufacturers. Further plans for investigation include refined scatter fractions for various concrete compositions, scatter fraction measurement, and simulation of photo-nuclear interaction within the maze barrier for high-energy beams.« less
1. INTERIOR VIEW WITH NAVE, BARREL VAULTED SOLEA, ICONOSTAS WITH ...
1. INTERIOR VIEW WITH NAVE, BARREL VAULTED SOLEA, ICONOSTAS WITH ICON AND SANCTUARY. IN ARCH ABOVE THE SANCTUARY IS THE TABLE OF ABRAHAM. THE ICONOSTAS INCLUDES ICONS OF THE ARCHANGEL MICHAEL, THE HOLY TRINITY, MOTHER OF GOD HOLDING THE CHRIST CHILD, JESUS. - Holy Trinity-Holy Cross Greek Orthodox Church, 200 Nineteenth Street South, Birmingham, Jefferson County, AL
Radiological features of the skull in Klinefelter's syndrome and male hypogonadism.
Kosowicz, J; Rzymski, K
1975-07-01
Skull radiographs were performed in 21 cases of Klinefelter's syndrome and in 30 cases of eunuchoidism. The radiographic changes of the skull in Klinefelter's syndrome are: temporal flattening, decreased width of the vault, narrowing of the mandible, decreased length of the skull, shortening of the anterior fossa cranii, decrease in the angle of the base, thinning of the vault bones at the major fontanelle, premature and excessive calcification of the coronal suture, deepening of the posterior fossa and shortening of the mandibular rami. In hypogonadotropic eunuchoidism the skull radiographs show: small mastoid processes, fine bones of the vault, small sella turcica, club-shaped clinoid processes, excessive development of sphenoidal sinuses and in the fourth and later decades of life a diminished bone density (osteoporosis).
Criticality Calculations with MCNP6 - Practical Lectures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Forrest B.; Rising, Michael Evan; Alwin, Jennifer Louise
2016-11-29
These slides are used to teach MCNP (Monte Carlo N-Particle) usage to nuclear criticality safety analysts. The following are the lecture topics: course information, introduction, MCNP basics, criticality calculations, advanced geometry, tallies, adjoint-weighted tallies and sensitivities, physics and nuclear data, parameter studies, NCS validation I, NCS validation II, NCS validation III, case study 1 - solution tanks, case study 2 - fuel vault, case study 3 - B&W core, case study 4 - simple TRIGA, case study 5 - fissile mat. vault, criticality accident alarm systems. After completion of this course, you should be able to: Develop an input modelmore » for MCNP; Describe how cross section data impact Monte Carlo and deterministic codes; Describe the importance of validation of computer codes and how it is accomplished; Describe the methodology supporting Monte Carlo codes and deterministic codes; Describe pitfalls of Monte Carlo calculations; Discuss the strengths and weaknesses of Monte Carlo and Discrete Ordinants codes; The diffusion theory model is not strictly valid for treating fissile systems in which neutron absorption, voids, and/or material boundaries are present. In the context of these limitations, identify a fissile system for which a diffusion theory solution would be adequate.« less
29 CFR 801.14 - Exemption for employers providing security services.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... For example, a security system specially designed to protect diamonds kept in a home vault of a... general prohibition against polygraph tests for certain armored car, security alarm, and security guard..., 801.24, 801.25, 801.26, and 801.35 of this part, section 7(e) permits the use of polygraph tests on...
29 CFR 801.14 - Exemption for employers providing security services.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... For example, a security system specially designed to protect diamonds kept in a home vault of a... general prohibition against polygraph tests for certain armored car, security alarm, and security guard..., 801.24, 801.25, 801.26, and 801.35 of this part, section 7(e) permits the use of polygraph tests on...
An Extensive Compendium on Good Practices in Secondary Education in Greece
ERIC Educational Resources Information Center
Zacharis, Konstantinos
2017-01-01
The establishment of a competitive, meritocratic and engaging culture inside the educational system is one of the crucial elements that will determine not only its survival but also its evolution as a vault of social progress and cultural elevation. Within this frame, mechanisms that can establish new relationships for excellence and innovation…
Using data mining to build a customer-focused organization.
Okasha, A
1999-08-01
Data mining is a new buzz word in managed care. More than simply a method of unlocking a vault of useful information in MCO data banks and warehouses, the author believes that it can help steer an organization through the reengineering process, leading to the health system's transformation toward a customer-focused organization.
75 FR 16120 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-31
... Management and Budget (OMB) delegated to the Board of Governors of the Federal Reserve System (Board) its... of Management and Budget, New Executive Office Building, Room 10235, 725 17th Street, NW., Washington... of Transaction Accounts, Other Deposits and Vault Cash (FR 2900; OMB No. 7100-0087) need not provide...
Zarzo, Manuel; Fernández-Navajas, Angel; García-Diego, Fernando-Juan
2011-01-01
We describe the performance of a microclimate monitoring system that was implemented for the preventive conservation of the Renaissance frescoes in the apse vault of the Cathedral of Valencia, that were restored in 2006. This system comprises 29 relative humidity (RH) and temperature sensors: 10 of them inserted into the plaster layer supporting the fresco paintings, 10 sensors in the walls close to the frescoes and nine sensors measuring the indoor microclimate at different points of the vault. Principal component analysis was applied to RH data recorded in 2007. The analysis was repeated with data collected in 2008 and 2010. The resulting loading plots revealed that the similarities and dissimilarities among sensors were approximately maintained along the three years. A physical interpretation was provided for the first and second principal components. Interestingly, sensors recording the highest RH values correspond to zones where humidity problems are causing formation of efflorescence. Recorded data of RH and temperature are discussed according to Italian Standard UNI 10829 (1999). PMID:22164100
D'Amore, G; Pacciani, E; Frederic, P; Caramella Crespi, V
2007-01-01
The present study describes human skeletal remains from Riparo della Rossa, a rock shelter in the Marche region (Central Italy). The remains consist of a cranial vault and a few non-articulated postcranial bones, possibly belonging to the same adult individual. As the cranial vault showed some morphological features that are unusual for a modern human (marked prominence of the supraorbital region, very prominent nasal bones and rather high thickness of the vault), an accurate anthropological analysis and quantification of the antiquity of the bones were required. The remains were dated with two different absolute dating methods, AMS (14)C and (235)U-(231)Pa non-destructive gamma-ray spectrometry (NDGRS), which produced discordant results: the uncalibrated (14)C dating produced 5690 +/- 80 BP for the cranial vault and 6110 +/- 80 BP for the clavicle; the NDGRS dating produced 10,000 +/- 3000 BP for the cranial vault. The sex discriminant morphological characters on the skull are not unequivocal, though the masculine ones appear more evident. The aims of the present paper are: to provide a morphological and metric description of the remains; to interpret their unusual morphological features; to attempt to attribute them to male or female sex and to one of the possible prehistoric cultural groups, according to dating results (Upper Palaeolithic, Mesolithic or Neolithic). The attribution was obtained by a Bayesian procedure taking into account the reliability of the combined information of morphological/metric features and absolute dating results. The results suggest that the Riparo della Rossa remains are best attributed to a male individual of the Neolithic age.
Trillium Horizon, A Small Portable Observatory Grade Seismometer For Direct Bury And Vault Use
NASA Astrophysics Data System (ADS)
Moores, A.; Parker, T.; Bainbridge, G.
2017-12-01
As of August 2017 almost 5 years of data have been collected from broadband seismic sensors designed for direct burial applications. These first posthole instruments have been deployed in a wide range of extremely challenging environments such as dynamic ice and snow environments, extreme wet and dry conditions in soils of high clay content, and steep creeping terrain. In all use cases the direct burial approach has consistently provided high quality data when compared to shallow vault installations. In this presentation we extract and analyze operational performance data, including tilt information from mass position time series recorded at direct burial installations and at temporary shallow vault deployments. This data shows that while higher tilt tolerance is required for data quality outcome certainty in some installations, the majority of installations can be addressed by a smaller instrument with a narrower tilt range hence reducing size and cost. The lessons learned from this real world field data have guided the development of a new smaller, less expensive instrument, Trillium Horizon.Based on this analysis and and user feedback from many direct burial deployments, the Trillium Horizon seismometer has been developed as a simple versatile instrument to span the majority of deployment scenarios and specific use cases including shallow direct bury deployments, traditional piers, and problematic wet vault installs. With its small size, robust waterproof case and connector, +/-1.5° tilt range, dual-purpose cable, and accessories for both posthole and vault installation, Trillium Horizon is optimized for usability as well as performance.
ERIC Educational Resources Information Center
Grandjean, Burke D.; Taylor, Patricia A.; Weiner, Jay
2002-01-01
During the women's all-around gymnastics final at the 2000 Olympics, the vault was inadvertently set 5 cm too low for a random half of the gymnasts. The error was widely viewed as undermining their confidence and subsequent performance. However, data from pretest and posttest scores on the vault, bars, beam, and floor indicated that the vault…
Secure voice-based authentication for mobile devices: vaulted voice verification
NASA Astrophysics Data System (ADS)
Johnson, R. C.; Scheirer, Walter J.; Boult, Terrance E.
2013-05-01
As the use of biometrics becomes more wide-spread, the privacy concerns that stem from the use of biometrics are becoming more apparent. As the usage of mobile devices grows, so does the desire to implement biometric identification into such devices. A large majority of mobile devices being used are mobile phones. While work is being done to implement different types of biometrics into mobile phones, such as photo based biometrics, voice is a more natural choice. The idea of voice as a biometric identifier has been around a long time. One of the major concerns with using voice as an identifier is the instability of voice. We have developed a protocol that addresses those instabilities and preserves privacy. This paper describes a novel protocol that allows a user to authenticate using voice on a mobile/remote device without compromising their privacy. We first discuss the Vaulted Verification protocol, which has recently been introduced in research literature, and then describe its limitations. We then introduce a novel adaptation and extension of the Vaulted Verification protocol to voice, dubbed Vaulted Voice Verification (V3). Following that we show a performance evaluation and then conclude with a discussion of security and future work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feizollahi, F.; Shropshire, D.
This Waste Management Facility Cost Information (WMFCI) report for Greater-Than-Class C low-level waste (GTCC LLW) and DOE equivalent special case waste contains preconceptual designs and planning level life-cycle cost (PLCC) estimates for treatment, storage, and disposal facilities needed for management of GTCC LLW and DOE equivalent waste. The report contains information on 16 facilities (referred to as cost modules). These facilities are treatment facility front-end and back-end support functions (administration support, and receiving, preparation, and shipping cost modules); seven treatment concepts (incineration, metal melting, shredding/compaction, solidification, vitrification, metal sizing and decontamination, and wet/air oxidation cost modules); two storage concepts (enclosedmore » vault and silo); disposal facility front-end functions (disposal receiving and inspection cost module); and four disposal concepts (shallow-land, engineered shallow-land, intermediate depth, and deep geological cost modules). Data in this report allow the user to develop PLCC estimates for various waste management options. A procedure to guide the U.S. Department of Energy (DOE) and its contractor personnel in the use of estimating data is also included in this report.« less
31. View of mezzanine floor level in transmitter building no. ...
31. View of mezzanine floor level in transmitter building no. 102 showing various electronic central indicator panel to control building air conditioning, steam pressure, supply temperature, discharge temperature, supply pressure, transformer vault status, and radome conditioning system. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
Gluteo-vaginal fistula after posterior intravaginal slingplasty: a case report.
Grynberg, Michael; Teyssedre, Jacques; Staerman, Frederic
2009-07-01
In patients with posthysterectomy prolapse of the vaginal vault, the posterior intravaginal slingplasty (posterior IVS, Tyco Healthcare, USA) has been suggested as an alternative to traditional vaginal vault suspensions. The goal of this technique is to recreate the uterosacral ligaments and to reinforce the rectovaginal fascia with the use of prosthetic material. We report the case of a 53-year-old woman with a history of 27 months of perineal suppurative discharge after she underwent a vaginal vault prolapse and rectocele repair using a posterior IVS (Tyco Healthcare, USA). The IVS tape was reinforced by interposing a rectovaginal monofilament polypropylene mesh (Parietex, Sofradim, France). Imaging studies and surgical exploration confirmed infection of the IVS mesh with the formation of a gluteo-vaginal fistula while the rectovaginal mesh was intact.
Automatic public access to documents and maps stored on and internal secure system.
NASA Astrophysics Data System (ADS)
Trench, James; Carter, Mary
2013-04-01
The Geological Survey of Ireland operates a Document Management System for providing documents and maps stored internally in high resolution and in a high level secure environment, to an external service where the documents are automatically presented in a lower resolution to members of the public. Security is devised through roles and Individual Users where role level and folder level can be set. The application is an electronic document/data management (EDM) system which has a Geographical Information System (GIS) component integrated to allow users to query an interactive map of Ireland for data that relates to a particular area of interest. The data stored in the database consists of Bedrock Field Sheets, Bedrock Notebooks, Bedrock Maps, Geophysical Surveys, Geotechnical Maps & Reports, Groundwater, GSI Publications, Marine, Mine Records, Mineral Localities, Open File, Quaternary and Unpublished Reports. The Konfig application Tool is both an internal and public facing application. It acts as a tool for high resolution data entry which are stored in a high resolution vault. The public facing application is a mirror of the internal application and differs only in that the application furnishes high resolution data into low resolution format which is stored in a low resolution vault thus, making the data web friendly to the end user for download.
2009-02-01
power battery box and controllers, WiFi radio, network switch, vault seismometers, infrasonic digitizers, and excess cabling. In addition to the...installed around the boreholes. Immediately upon completion, each site will be cleared of all unused equipment, debris, materials, and trash . All...controllers, WiFi radio, network switch, vault seismometers, infrasonic digitizers, and excess cabling. In addition to the permanent infrastructure listed
Reddy, Srijaya K; Swink, Jonathan M; Rogers, Gary F; Myseros, John S; Keating, Robert F; Santos, Domiciano N
2016-07-15
Transfusion-free surgery for the Jehovah's Witness patient has been described, but there are few reports in pediatric patients undergoing major elective surgery. We present 2 patients of the Jehovah's Witness faith affected with craniosynostosis who underwent transfusion-free calvarial vault reconstructions using several blood conservation approaches, including the use of antifibrinolytic ε-aminocaproic acid.
LPT. EBOR (TAN646) interior, installing reactor in STF pool ("vault"). ...
LPT. EBOR (TAN-646) interior, installing reactor in STF pool ("vault"). Pressure vessel shows core barrel and outlet nozzle (next to man below) to inner duct weld, which is prepared and in position for stress relieving. Camera facing southeast. Photographer: Comiskey. Date: January 20, 1965. INEEL negative no. 65-239 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
NASA Astrophysics Data System (ADS)
Antonelli, Charles J.; Honeyman, Peter
2001-02-01
This paper describes the Advanced Packet Vault, a technology for creating such a record by collecting and securely storing all packets observed on a network, with a scalable architecture intended to support network speeds in excess of 100 Mbps. Encryption is used to preserve users' security and privacy, permitting selected traffic to be made available without revealing other traffic. The Vault implementation, based on Linux and OpenBSD, is open-source.
14. Photocopy of1931 drawing titled: BUILDING 78, FIRE PROOF VAULTS ...
14. Photocopy of1931 drawing titled: BUILDING 78, FIRE PROOF VAULTS FOR GENERAL FILES; PLAN, ELEVATION, SECTIONS. HABS photograph is an 8x10' contact print made from a high contrast copy negative of the original drawing in the collection of Department of Public Works, Puget Sound Naval Shipyard, Bremerton, WA. - Puget Sound Naval Shipyard, Administration Building, Farragut Avenue, Bremerton, Kitsap County, WA
Bone mineral density of the skull in premenopausal women.
Turner, A S; Maillet, J M; Mallinckrodt, C; Cordain, L
1997-08-01
Dual-energy X-ray absorptiometry (DXA) of the head has received little attention. We used DXA to measure bone mineral density (BMD) of the entire skull including the mandible (BMDHead) and BMD of the cranial vault (BMDVault) in 91 normal young women. We also measured BMD of the total body (BMDTotal body), proximal femur ("total femur"), and lumbar vertebrae (L1-L4). BMD (g/cm2; mean +/- SE) was 1.032 +/- 0.011 for L1-L4, 0.995 +/- 0.011 for total femur, and 2.283 +/- 0.028 for BMDVault (cranial vault) and the mean body weight of all subjects was 59.8 kg. Correlation between BMD Vault and BMDHead was -0.004 g/cm2 suggesting that these two measurements of bone mass of the skull were similar. To determine the correlation between the different variables after accounting for external sources of variation, partial correlation derived from multiple regression was determined. Correlations between BMD at the various locations and with BMDTotal body were moderate to strong. Although small in magnitude, the partial correlations of body weight with BMDTotal body, total femur, and L1-L4 were of equal value in predicting BMDTotal body and further, BMDVault was not influenced by body weight. Including body weight in multiple regression in addition to total femur or L1-L4 removed the extraneous variation due to body weight, and predictions of MBDTotal body were as reliable as when BMDVault was based on goodness of fit tests (P = 0.314). The techniques used to measure BMD of the cranial vault is a relatively new variation of DXA technology. The precision was as good as other measurements of bone mass of the entire skull (including the mandible). Because the cranial vault is less sensitive to mechanical influences, it may be a region where response to therapy could be evaluated. The cranial vault may be a useful area to study certain heritable diseases that affect the skeleton, skeletal artifact, or evaluation of oral bone loss.
1. EXTERIOR OF BUILDING 125 FROM MAIN PLANT 4 RESIDENTIAL ...
1. EXTERIOR OF BUILDING 125 FROM MAIN PLANT 4 RESIDENTIAL STREET SHOWING BUILDING AT PHOTO RIGHT CENTER (WITH WHITE JEEP PARKED IN FRONT) BETWEEN WORKER COTTAGE (BUILDING 115) AT PHOTO LEFT AND RECREATION HALL (BUILDING 109) AT PHOTO RIGHT. VIEW TO SOUTH. - Bishop Creek Hydroelectric System, Plant 4, Lightning Arrestor Vault, Bishop Creek, Bishop, Inyo County, CA
Treatment vault shielding for a flattening filter-free medical linear accelerator
NASA Astrophysics Data System (ADS)
Kry, Stephen F.; Howell, Rebecca M.; Polf, Jerimy; Mohan, Radhe; Vassiliev, Oleg N.
2009-03-01
The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target current requirements were determined from treatment planning studies of several disease sites with, and without, the flattening filter. The flattened beam shielding data were compared to data published in NCRP Report No. 151, and the unflattened beam shielding data were presented relative to the NCRP data. Finally, the shielding requirements for a typical treatment vault were determined for a single-energy (6 MV) linac and a dual-energy (6 MV/18 MV) linac. With the exception of large-angle patient scatter fractions and wall scatter fractions, the vault shielding parameters were reduced when the flattening filter was removed. Much of this reduction was consistent with the reduced average energy of the FFF beams. Primary beam TVLs were reduced by 12%, on average, and small-angle scatter fractions were reduced by up to 30%. Head leakage was markedly reduced because less integral target current was required to deliver the target dose. For the treatment vault examined in the current study, removal of the flattening filter reduced the required thickness of the primary and secondary barriers by 10-20%, corresponding to 18 m3 less concrete to shield the single-energy linac and 36 m3 less concrete to shield the dual-energy linac. Thus, a shielding advantage was found when the linac was operated without the flattening filter. This translates into a reduction in occupational exposure and/or the cost and space of shielding.
Treatment vault shielding for a flattening filter-free medical linear accelerator.
Kry, Stephen F; Howell, Rebecca M; Polf, Jerimy; Mohan, Radhe; Vassiliev, Oleg N
2009-03-07
The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target current requirements were determined from treatment planning studies of several disease sites with, and without, the flattening filter. The flattened beam shielding data were compared to data published in NCRP Report No. 151, and the unflattened beam shielding data were presented relative to the NCRP data. Finally, the shielding requirements for a typical treatment vault were determined for a single-energy (6 MV) linac and a dual-energy (6 MV/18 MV) linac. With the exception of large-angle patient scatter fractions and wall scatter fractions, the vault shielding parameters were reduced when the flattening filter was removed. Much of this reduction was consistent with the reduced average energy of the FFF beams. Primary beam TVLs were reduced by 12%, on average, and small-angle scatter fractions were reduced by up to 30%. Head leakage was markedly reduced because less integral target current was required to deliver the target dose. For the treatment vault examined in the current study, removal of the flattening filter reduced the required thickness of the primary and secondary barriers by 10-20%, corresponding to 18 m(3) less concrete to shield the single-energy linac and 36 m(3) less concrete to shield the dual-energy linac. Thus, a shielding advantage was found when the linac was operated without the flattening filter. This translates into a reduction in occupational exposure and/or the cost and space of shielding.
Hall, Emma; Bishop, Daniel C.; Gee, Thomas I.
2016-01-01
This study aimed to determine the effect of plyometric training (PT) when added to habitual gymnastic training (HT) on handspring vault (HV) performance variables. Twenty youth female competitive gymnasts (Age: 12.5 ± 1.67 y) volunteered to participate and were randomly assigned to two independent groups. The experimental plyometric training group (PTG) undertook a six-week plyometric program, involving two additional 45 min PT sessions a week, alongside their HT, while the control group (CG) performed regular HT only. Videography was used (120 Hz) in the sagittal plane to record both groups performing three HVs for both the baseline and post-intervention trials. Furthermore, participants completed a countermovement jump test (CMJ) to assess the effect of PT on functional power. Through the use of Quintic biomechanics software, significant improvements (P < 0.05) were found for the PTG for run-up velocity, take-off velocity, hurdle to board distance, board contact time, table contact time and post-flight time and CMJ height. However, there were no significant improvements on pre-flight time, shoulder angle or hip angle on the vault for the PTG. The CG demonstrated no improvement for all HV measures. A sport-specific PT intervention improved handspring vault performance measures and functional power when added to the habitual training of youth female gymnasts. The additional two hours plyometric training seemingly improved the power generating capacity of movement-specific musculature, which consequently improved aspects of vaulting performance. Future research is required to examine the whether the improvements are as a consequence of the additional volume of sprinting and jumping activities, as a result of the specific PT method or a combination of these factors. PMID:26859381
Hall, Emma; Bishop, Daniel C; Gee, Thomas I
2016-01-01
This study aimed to determine the effect of plyometric training (PT) when added to habitual gymnastic training (HT) on handspring vault (HV) performance variables. Twenty youth female competitive gymnasts (Age: 12.5 ± 1.67 y) volunteered to participate and were randomly assigned to two independent groups. The experimental plyometric training group (PTG) undertook a six-week plyometric program, involving two additional 45 min PT sessions a week, alongside their HT, while the control group (CG) performed regular HT only. Videography was used (120 Hz) in the sagittal plane to record both groups performing three HVs for both the baseline and post-intervention trials. Furthermore, participants completed a countermovement jump test (CMJ) to assess the effect of PT on functional power. Through the use of Quintic biomechanics software, significant improvements (P < 0.05) were found for the PTG for run-up velocity, take-off velocity, hurdle to board distance, board contact time, table contact time and post-flight time and CMJ height. However, there were no significant improvements on pre-flight time, shoulder angle or hip angle on the vault for the PTG. The CG demonstrated no improvement for all HV measures. A sport-specific PT intervention improved handspring vault performance measures and functional power when added to the habitual training of youth female gymnasts. The additional two hours plyometric training seemingly improved the power generating capacity of movement-specific musculature, which consequently improved aspects of vaulting performance. Future research is required to examine the whether the improvements are as a consequence of the additional volume of sprinting and jumping activities, as a result of the specific PT method or a combination of these factors.
Serati, Maurizio; Braga, Andrea; Bogani, Giorgio; Leone Roberti Maggiore, Umberto; Sorice, Paola; Ghezzi, Fabio; Salvatore, Stefano
2015-07-01
Sacrocolpopexy is considered the gold standard treatment for vaginal vault prolapse. However, the vaginal approach is very common, with 80-90 % of procedures being performed via this route. The aim of this study was to evaluate the safety and efficacy of iliococcygeus (ICG) fixation in the treatment of vaginal vault prolapse, with a minimum follow-up of 5 years. We prospectively enrolled women with symptomatic vaginal vault prolapse (Pelvic Organ Prolapse Quantification [POP-Q] stage ≥2) who were treated with ICG fixation. Subjective success was defined in the case of Patient Global Impression of Improvement ≤ 2 and an absence of bulging symptoms. Objective success was defined as stage of prolapse < 2 in all compartments. Overall success rate was defined as women without prolapse symptoms, PGI-I ≤ 2, stage of prolapse < 2, and no need for other surgery. All women filled in the Prolapse Quality of Life (P-QOL) questionnaire both at the preoperative visit and at every follow-up visit. Multiple logistic regression was performed to identify factors involved in the risk of recurrent POP. After a median (range) follow-up of 68.8 (60-92) months the subjective, objective, and overall cure rates were 88.6 % (39 out of 44), 84.1 % (37 out of 44), and 84.1 % (37 out of 44) respectively. Only preoperative stage IV vault descensus independently predicted POP recurrence after iliococcygeus fixation (OR: 8.78 [95 % CI: 1.31-9.42]; p < 0.001). Iliococcygeus fixation is a safe and effective surgical technique for the treatment of vaginal vault prolapse with long-lasting effectiveness.
Cunningham, Gregory; Freebody, John; Smith, Margaret M; Taha, Mohy E; Young, Allan A; Cass, Benjamin; Giuffre, Bruno
2018-05-16
Most glenoid version measurement methods have been validated on 3-dimensionally corrected axial computed tomography (CT) slices at the mid glenoid. Variability of the vault according to slice height and angulation has not yet been studied and is crucial for proper surgical implant positioning. The aim of this study was to analyze the variation of the glenoid vault compared with the Friedman angle according to different CT slice heights and angulations. The hypothesis was that the Friedman angle would show less variability. Sixty shoulder CT scans were retrieved from a hospital imaging database and were reconstructed in the plane of the scapula. Seven axial slices of different heights and coronal angulations were selected, and measurements were carried out by 3 observers. Mid-glenoid mean version was -8.0° (±4.9°; range, -19.6° to +7.0°) and -2.1° (±4.7°; range, -13.0° to +10.3°) using the vault method and Friedman angle, respectively. For both methods, decreasing slice height or angulation did not significantly alter version. Increasing slice height or angulation significantly increased anteversion for the vault method (P < .001). Both interobserver reliability and intraobserver reliability were significantly higher using the Friedman angle. Version at the mid and lower glenoid is similar using either method. The vault method shows less reliability and more variability according to slice height or angulation. Yet, as it significantly differs from the Friedman angle, it should still be used in situations where maximum bone purchase is sought with glenoid implants. For any other situation, the Friedman angle remains the method of choice. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Wolfswinkel, Erik M; Howell, Lori K; Fahradyan, Artur; Azadgoli, Beina; McComb, J Gordon; Urata, Mark M
2017-12-01
Of U.S. craniofacial and neurosurgeons, 94 percent routinely admit patients to the intensive care unit following cranial vault remodeling for correction of sagittal synostosis. This study aims to examine the outcomes and cost of direct ward admission following primary cranial vault remodeling for sagittal synostosis. An institutional review board-approved retrospective review was undertaken of the records of all patients who underwent primary cranial vault remodeling for isolated sagittal craniosynostosis from 2009 to 2015 at a single pediatric hospital. Patient demographics, perioperative course, and outcomes were recorded. One hundred ten patients met inclusion criteria with absence of other major medical problems. Average age at operation was 6.7 months, with a mean follow-up of 19.8 months. Ninety-eight patients (89 percent) were admitted to a general ward for postoperative care, whereas the remaining 12 (11 percent) were admitted to the intensive care unit for preoperative or perioperative concerns. Among ward-admitted patients, there were four (3.6 percent) minor complications; however, there were no major adverse events, with none necessitating intensive care unit transfers from the ward and no mortalities. Average hospital stay was 3.7 days. The institution's financial difference in cost of intensive care unit stay versus ward bed was $5520 on average per bed per day. Omitting just one intensive care unit postoperative day stay for this patient cohort would reduce projected health care costs by a total of $540,960 for the study period. Despite the common practice of postoperative admission to the intensive care unit following cranial vault remodeling for sagittal craniosynostosis, the authors suggest that postoperative care be considered on an individual basis, with only a small percentage requiring a higher level of care. Therapeutic, III.
Crosby, Erin C.; Berger, Mitchell B.; DeLancey, John O. L.
2014-01-01
The combination of vesicovaginal fistula and complete vaginal vault prolapse is rare. The only published treatment recommendations concern partial colpocleisis; an option that precludes intercourse. In this case report, we describe successful repair of this problem with a Latzko fistula repair and concomitant Michigan four-wall sacrospinous ligament suspension: curing the fistula, correcting the prolapse and preserving sexual function. PMID:22983277
1992-08-01
recommend that representatives of the WES Concrete Technology Division be onsite during the placement and postplacement phases to offer technical...written before field placement. PREFACE The work described in this report is part of an ongoing research effort accomplished in the Concrete Technology ... Division (CTD), Structures Laboratory (SL), U.S. Army Engineer Waterways Experiment Station (WES), under Interagency Agreement from the Department of
NASA Astrophysics Data System (ADS)
Duffó, G. S.; Farina, S. B.; Arva, E. A.; Giordano, C. M.; Lafont, C. J.
2006-11-01
The Argentine Atomic Energy Commission (CNEA) is responsible of the development of a management nuclear waste disposal programme. This programme contemplates the design and construction of a facility for the final disposal of intermediate-level radioactive waste. The proposed concept is the near-surface monolithic repository similar to those in operation in El Cabril, Spain. The design of this type of repository is based on the use of multiple, independent and redundant barriers. Since the vault and cover are major components of the engineered barriers, the durability of these concrete structures is an important aspect for the facilities integrity. This work presents a laboratory and field investigation performed for the last 6 years on reinforced concrete specimens, in order to predict the service life of the intermediate level radioactive waste disposal vaults from data obtained from electrochemical techniques. On the other hand, the development of sensors that allow on-line measurements of rebar corrosion potential and corrosion current density; incoming oxygen flow that reaches the metal surface; concrete electrical resistivity and chloride concentration is shown. Those sensors, properly embedded in a new full scale vault (nowadays in construction), will allow the monitoring of the corrosion process of the steel rebars embedded in thestructure.
Dines, David M; Gulotta, Lawrence; Craig, Edward V; Dines, Joshua S
Complex glenoid deformities present the most difficult challenges in shoulder arthroplasty. These deformities may be caused by severe degenerative or congenital deformity, posttraumatic anatomy, tumor, or, in most cases, bone loss after glenoid failure in anatomical total shoulder arthroplasty. Methods of treating severe bone loss have included inlay and onlay bone-graft options with augmented fixation and, in severe cases, salvage hemiarthroplasty with limited goal expectations. Unfortunately, none of these methods has provided consistently satisfactory reproducible results. In fact, each has had high rates of failure and complications. Borrowing from hip and knee arthroplasty surgeons' experience in using CAD/CAM (computer-aided design/computer-aided manufacturing) patient-specific implants to fill significant bony defects, Dr. D. M. Dines developed a glenoid vault reconstruction system (VRS) in conjunction with the Comprehensive Shoulder Arthroplasty System (Zimmer Biomet) to treat severe glenoid bone deficiency. The VRS is patient-specific; each case involves making a preoperative plan based on 3-dimensional reconstruction of a 2-dimensional computed tomography scan. The patient-specific implant and instrumentation that are created are used to reconstruct the deformed glenoid in an anatomical position without the need for additional bone graft. In this article, we describe the implant and its indications, technical aspects of production, and surgical technique.
The mixed low-level waste problem in BE/NWN capsule
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hensley, D.C.
1999-07-01
The Boh Environmental, LLC (BE) and Northwest Nuclear, LLC (NWN) program addresses the problem of diminishing capacity in the United States to store mixed waste. A lack of an alternative program has caused the US Department of Energy (DOE) to indefinitely store all of its mixed waste in Resource Conservation and Recovery Act (RCRA) compliant storage facilities. Unfortunately, this capacity is fast approaching the administrative control limit. The combination of unique BE encapsulation and NWN waste characterization technologies provides an effective solution to DOE's mixed-waste dilemma. The BE ARROW-PAK technique encapsulates mixed low-level waste (MLLW) in extra-high molecular weight, high-densitymore » polyethylene, pipe-grade resin cylinders. ARROW-PAK applications include waste treatment, disposal, transportation (per 49 CFR 173), vault encasement, and interim/long-term storage for 100 to 300 yr. One of the first demonstrations of this treatment/storage technique successfully treated 880 mixed-waste debris drums at the DOE Hanford Site in 1997. NWN, deploying the APNea neutron assay technology, provides the screening and characterization capability necessary to ensure that radioactive waste is correctly categorized as either transuranic (TRU) or LLW. MLLW resulting from D and D activities conducted at the Oak Ridge East Tennessee Technology Park will be placed into ARROW-PAK containers following comprehensive characterization of the waste by NWN. The characterized and encapsulated waste will then be shipped to a commercial disposal facility, where the shipments meet all waste acceptance criteria of the disposal facility including treatment criteria.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsieh, M; Balter, P; Beadle, B
Purpose: A fixed horizontal-beam linac, where the patient is treated in a seated position, could lower the overall costs of the treatment unit and room shielding substantially. This design also allows the treatment room and control area to be contained within a reduced space, such as a shipping container. The main application is the introduction of low-cost, high-quality radiation therapy to low- and middle-income regions. Here we consider shielding for upright treatments with a fixed-6MV-beam linac in a shipping container and a conventional treatment vault. Methods: Shielding calculations were done for two treatment room layouts using calculation methods in NCRPmore » Report 151: (1) a shipping container (6m × 2.4m with the remaining space occupied by the console area), and (2) the treatment vault in NCRP 151 (7.8m by 5.4m by 3.4m). The shipping container has a fixed gantry that points in one direction at all times. For the treatment vault, various beam directions were evaluated. Results: The shipping container requires a primary barrier of 168cm concrete (4.5 TVL), surrounded by a secondary barrier of 3.6 TVL. The other walls require between 2.8–3.3 TVL. Multiple shielding calculations were done along the side wall. The results show that patient scatter increases in the forward direction and decreases dramatically in the backward direction. Leakage scatter also varies along the wall, depending largely on the distance between the gantry and the wall. For the treatment room, fixed-beam requires a slightly thicker primary barrier than the conventional linac (0.6 TVL), although this barrier is only needed in the center of one wall. The secondary barrier is different only by 0–0.2 TVL. Conclusion: This work shows that (1) the shipping container option is achievable, using indigenous materials for shielding and (2) upright treatments can be performed in a conventional treatment room with minimal additional shielding. Varian Medical Systems.« less
Conference room 211, adjacent to commander's quarters, with vault door ...
Conference room 211, adjacent to commander's quarters, with vault door at right. Projection area at center is equipped with automatic security drapes. Projection room uses a 45 degree mirror to reflect the image onto the frosted glass screen. Door on far left leads to display area senior battle staff viewing bridge, and the commander's quarters - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA
Adding EUNIS and VAULT rocket data to the VSO with Modern Perl frameworks
NASA Astrophysics Data System (ADS)
Mansky, Edmund
2017-08-01
A new Perl code is described, that uses the modern Object-oriented Moose framework, to add EUNIS and VAULT rocket data to the Virtual Solar Observatory website. The code permits the easy fixing of FITS header fields in the case where some FITS fields that are required are missing from the original data files. The code makes novel use of the Moose extensions “before” and “after” to build in dependencies so that database creation of tables occurs before the loading of data, and that the validation of file-dependent tables occurs after the loading is completed. Also described is the computation and loading of the deferred FITS field CHECKSUM into the database following the loading and validation of the file-dependent tables. The loading of the EUNIS 2006 and 2007 flight data, and the VAULT 2.0 flight data is described in detail as illustrative examples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashwood, T.L.; Marsh, J.D. Jr.
1994-04-01
This report presents a compilation of groundwater monitoring data from Solid Waste Storage Area (SWSA) 5 North at Oak Ridge National Laboratory (ORNL) between November 1989 and September 1993. Monitoring data were collected as part of the Active Sites Environmental Monitoring Program that was implemented in 1989 in response to DOE Order 5820.2A. SWSA 5 North was established for the retrievable storage of transuranic (TRU) wastes in 1970. Four types of storage have been used within SWSA 5 North: bunkers, vaults, wells, and trenches. The fenced portion of SWSA 5 North covers about 3.7 ha (9 acres) in the Whitemore » Oak Creek watershed south of ORNL. The area is bounded by White Oak Creek and two ephemeral tributaries of White Oak Creek. Since 1989, groundwater has been monitored in wells around SWSA 5 North. During that time, elevated gross alpha contamination (reaching as high as 210 Bq/L) has consistently been detected in well 516. This well is adjacent to burial trenches in the southwest corner of the area. Water level measurements in wells 516 and 518 suggest that water periodically inundates the bottom of some of those trenches. Virtually all of the gross alpha contamination is generated by Curium 244 and Americium 241. A special geochemical investigation of well 516 suggests that nearly all of the Curium 44 and Americium 241 is dissolved or associated with dissolved organic matter. These are being transported at the rate of about 2 m/year from the burial trenches, through well 516, to White Oak Creek, where Curium 244 has been detected in a few bank seeps. Concentrations at these seeps are near detection levels (<1 Bq/L).« less
Designing a new post-hole seismological station on Antarctica inlandsis (Concordia station)
NASA Astrophysics Data System (ADS)
Bès de Berc, M.; Maggi, A.; Leveque, J. J.; Thore, J. Y.
2015-12-01
Concordia (75°S 123°E) is a scientific base operated by French and Italian polar institutes IPEV (Institut Paul-Emile Victor) and PNRA (Programma Nazionale di Ricerche in Antartide, and is located on the inlandsis of the East Antarctica plateau. It hosts a seismological station CCD which has provided observatory quality data since the year 2000, has been integrated into the Geoscope network since 2008 and whose data are now available in real-time from IRIS. The current seismic vault is located 800m from Concordia base, as far away as is deemed logistically possible by IPEV, at a depth of 12m. The vault is thermally very stable, but given the close distance to the base, suffers from increased diurnal noise (up to 40 dB) at frequencies above 1Hz, especially in the summer season. Anthropic noise is trapped in the firn (snow) layer, which forms an 100-110m thick waveguide, and is picked up very easily in the seismic vault. The vault is made from steel containers buried vertically in the snow. The hydrostatic pressure of the snow is deforming them: we see container cracking events on the seismograms, and also visual evidence of container deformation inside the vault. In the near future, this deformation will create a security problem.We have decided to progressively abandon our current vault, and construct a new post-hole seismological installation nearby. We plan to drill to 130m depth, which would place us below the firn layer waveguide and also below the ice pinch-out depth. To be able to run the station for several years and change or service the instrumentation if required, we need to keep the hole open, to avoid any hydrostatic movement, and to maintain good coupling between the sensor and the surrounding hard ice. To achieve these goals, we shall install a casing in the fin layer and then drill a few meters more without casing in hard ice. After installing the instrument, we shall then fill the whole hole with a drilling fluid whose density is similar to that of ice.The drilling will be carried out by the French drilling facility C2FN (Centre de Carottage et de Forage National) of the CNRS (Centre National de la Recherche Scientifique), and the is planned for the 2018-2019 summer season.
1984-04-01
firing ranges, and training areas--four conventional methods have been used to treat human wastes: trenching and cat holing, pit latrines, vault toilets...stations, and training and recrea- tional areas. The Army now uses four conventional methods to treat human wastes at such sites: trenching and cat ...holing, pit latrines, vault toilets, and chemical toilets ("port-a-pots"). Trenching and cat holing are used when troops are on bivouac; waste is
Structural Concepts Study of Non-circular Fuselage Configurations
NASA Technical Reports Server (NTRS)
Mukhopadhyay, Vivel
1996-01-01
A preliminary study of structural concepts for noncircular fuselage configurations is presented. For an unconventional flying-wing type aircraft, in which the fuselage is inside the wing, multiple fuselage bays with non-circular sections need to be considered. In a conventional circular fuselage section, internal pressure is carried efficiently by a thin skin via hoop tension. If the section is non-circular, internal pressure loads also induce large bending stresses. The structure must also withstand additional bending and compression loads from aerodynamic and gravitational forces. Flat and vaulted shell structural configurations for such an unconventional, non-circular pressurized fuselage of a large flying-wing were studied. A deep honeycomb sandwich-shell and a ribbed double-wall shell construction were considered. Combinations of these structural concepts were analyzed using both analytical and simple finite element models of isolated sections for a comparative conceptual study. Weight, stress, and deflection results were compared to identify a suitable configuration for detailed analyses. The flat sandwich-shell concept was found preferable to the vaulted shell concept due to its superior buckling stiffness. Vaulted double-skin ribbed shell configurations were found to be superior due to their weight savings, load diffusion, and fail-safe features. The vaulted double-skin ribbed shell structure concept was also analyzed for an integrated wing-fuselage finite element model. Additional problem areas such as wing-fuselage junction and pressure-bearing spar were identified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mihailidis, D
2015-06-15
Purpose: To date, there isn’t formal approach for flattening filter-free (FFF) linac vault shielding evaluation, thus, we propose an extension to NCRP#151 to accommodate the recent large number of FFF linac installations.Methods and Materials: We extended the approach in NCRP#151 to design two Truebeam vaults in our new cancer center for hypofractionated treatments. Monte Carlo calculations have characterized primary, scattered, leakage and neutron radiations from FFF-modes. These calculations have shown that: a) FFF primary beam is softer on the central-axis compared to flattening filtered (FF), b) the lateral dose profile is peaked on the central axis and less integral targetmore » current is required to generate the same tumor dose with the FF beam. Thus, the TVLs for FFF mode are smaller than those of the FF mode and the scatter functions of the FF mode (NCRP#151) may not be appropriate for FFF-mode, c) the neutron source strength and fluence for 18X-FFF is smaller than 18X-FF, but it is not of a concern here, no 18X-FFF-mode is available on the linac under investigation. Results: These barrier thickness are smaller (12% reduction on the average) than those computed for conventional FF mode with same realistic primary workload since, the primary TVLs used here are smaller and the WL is smaller than the conventional (almost half reduced), keeping the TADR in tolerance. Conclusions: A comprehensive method for shielding barrier calculations based on dedicated data for FFF-mode linacs is highly desired. Meanwhile, we provide an extension to NCRP#151 to accommodate the shielding design of such installations. It is also shown that if a vault is already designed for IMRT/VMAT and SABR hypofractionated treatments with FFF-mode linac, the vault can also be used for a FFF mode linac replacement, leaving some leeway for slightly higher workload on the FFF linac.« less
Migrating to 9.1 -- Why Not...How Hard Could It Be?
NASA Technical Reports Server (NTRS)
Little, Keith; Miller, Carole; Schwindt, Paul; Zimmerman, Cheryl
2011-01-01
With 19+ Million documents in the 8.0 Vault. the decision was to migrate only selected top-level Documents, Drawings, Models and Assemblies to Kennedy Space Center's Brand-Spankin-New 9.1 Windchill system. Come with us as we detail our journey. We'll share our triumphs. tools, and approaches, as well as our challenges (and a surprise or two) discovered on the trip.
Accomplishments under the Airport Improvement Program: Fiscal Year 1988
1988-01-01
PATTERSON 03 $230,000 REHABILITATE RUNWAY LIGHTING; RELOCATE HARRY P WILLIAMS MEMORIAL ELECTRIC VAULT AND VISUAL APPROACH AIDS; (GENERAL AVIATION...650,000 CONSTRUCT TAXIWAY AND APRON (SITE ERNEST A LOVE FIELD PREPARATION) (COMMERCIAL SERVICE) SEDONA 04 $210,804 CONSTRUCT AND LIGHT APRON SEDONA...INSTALL INSTRUMENT LANDING AND APPROACH LIGHTING SYSTEMS; ACQUIRE LAND FOR DEVELOPMENT AND APPROACHES TEXARKANA 06 $802,484 RECONSTRUCT, OVERLAY AND LIGHT
Radiological performance assessment for the E-Area Vaults Disposal Facility. Appendices A through M
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, J.R.
1994-04-15
These document contains appendices A-M for the performance assessment. They are A: details of models and assumptions, B: computer codes, C: data tabulation, D: geochemical interactions, E: hydrogeology of the Savannah River Site, F: software QA plans, G: completeness review guide, H: performance assessment peer review panel recommendations, I: suspect soil performance analysis, J: sensitivity/uncertainty analysis, K: vault degradation study, L: description of naval reactor waste disposal, M: porflow input file. (GHH)
60. VIEW OF THE CURRENT TRANSFORMER VAULT. THIS CURRENT TRANSFORMER ...
60. VIEW OF THE CURRENT TRANSFORMER VAULT. THIS CURRENT TRANSFORMER WAS USED TO SENSE HIGH CURRENT BEING GENERATED ON GENERATOR NUMBER 3 AND REDUCE IT TO A LOWER, EXACT ANALOG VALUE THAT COULD BE SAFELY HANDLED AND MONITORED WITH THE CONTROL CIRCUITRY. THE CURRENT TRANSFORMER IS LOCATED IN THE CENTER OF THE PHOTOGRAPH. THE CONNECTING BUS ABOVE THE TRANSFORMER WAS REMOVED FOR SALVAGE. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT
SU-F-BRB-05: Collision Avoidance Mapping Using Consumer 3D Camera
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cardan, R; Popple, R
2015-06-15
Purpose: To develop a fast and economical method of scanning a patient’s full body contour for use in collision avoidance mapping without the use of ionizing radiation. Methods: Two consumer level 3D cameras used in electronic gaming were placed in a CT simulator room to scan a phantom patient set up in a high collision probability position. A registration pattern and computer vision algorithms were used to transform the scan into the appropriate coordinate systems. The cameras were then used to scan the surface of a gantry in the treatment vault. Each scan was converted into a polygon mesh formore » collision testing in a general purpose polygon interference algorithm. All clinically relevant transforms were applied to the gantry and patient support to create a map of all possible collisions. The map was then tested for accuracy by physically testing the collisions with the phantom in the vault. Results: The scanning fidelity of both the gantry and patient was sufficient to produce a collision prediction accuracy of 97.1% with 64620 geometry states tested in 11.5 s. The total scanning time including computation, transformation, and generation was 22.3 seconds. Conclusion: Our results demonstrate an economical system to generate collision avoidance maps. Future work includes testing the speed of the framework in real-time collision avoidance scenarios. Research partially supported by a grant from Varian Medical Systems.« less
Development of a High Level Waste Tank Inspection System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Appel, D.K.; Loibl, M.W.; Meese, D.C.
1995-03-21
The Westinghouse Savannah River Technology Center was requested by it`s sister site, West Valley Nuclear Service (WVNS), to develop a remote inspection system to gather wall thickness readings of their High Level Waste Tanks. WVNS management chose to take a proactive approach to gain current information on two tanks t hat had been in service since the early 70`s. The tanks contain high level waste, are buried underground, and have only two access ports to an annular space between the tank and the secondary concrete vault. A specialized remote system was proposed to provide both a visual surveillance and ultrasonicmore » thickness measurements of the tank walls. A magnetic wheeled crawler was the basis for the remote delivery system integrated with an off-the-shelf Ultrasonic Data Acquisition System. A development program was initiated for Savannah River Technology Center (SRTC) to design, fabricate, and test a remote system based on the Crawler. The system was completed and involved three crawlers to perform the needed tasks, an Ultrasonic Crawler, a Camera Crawler, and a Surface Prep Crawler. The crawlers were computer controlled so that their operation could be done remotely and their position on the wall could be tracked. The Ultrasonic Crawler controls were interfaced with ABB Amdata`s I-PC, Ultrasonic Data Acquisition System so that thickness mapping of the wall could be obtained. A second system was requested by Westinghouse Savannah River Company (WSRC), to perform just ultrasonic mapping on their similar Waste Storage Tanks; however, the system needed to be interfaced with the P-scan Ultrasonic Data Acquisition System. Both remote inspection systems were completed 9/94. Qualifications tests were conducted by WVNS prior to implementation on the actual tank and tank development was achieved 10/94. The second inspection system was deployed at WSRC 11/94 with success, and the system is now in continuous service inspecting the remaining high level waste tanks at WSRC.« less
Chai, Orit; Peery, Dana; Bdolah-Abram, Tali; Moscovich, Efrat; Kelmer, Efrat; Klainbart, Sigal; Milgram, Joshua; Shamir, Merav H
2017-09-01
OBJECTIVE To characterize CT findings and outcomes in dogs with head trauma and design a prognostic scale. ANIMALS 27 dogs admitted to the Koret School Veterinary Teaching Hospital within 72 hours after traumatic head injury that underwent CT imaging of the head. PROCEDURES Data were extracted from medical records regarding dog signalment, history, physical and neurologic examination findings, and modified Glasgow coma scale scores. All CT images were retrospectively evaluated by a radiologist unaware of dog status. Short-term (10 days after trauma) and long-term (≥ 6 months after trauma) outcomes were determined, and CT findings and other variables were analyzed for associations with outcome. A prognostic CT-based scale was developed on the basis of the results. RESULTS Cranial vault fractures, parenchymal abnormalities, or both were identified via CT in 24 of 27 (89%) dogs. Three (11%) dogs had only facial bone fractures. Intracranial hemorrhage was identified in 16 (59%) dogs, cranial vault fractures in 15 (56%), midline shift in 14 (52%), lateral ventricle asymmetry in 12 (44%), and hydrocephalus in 7 (26%). Hemorrhage and ventricular asymmetry were significantly and negatively associated with short- and long-term survival, respectively. The developed 7-point prognostic scale included points for hemorrhage, midline shift or lateral ventricle asymmetry, cranial vault fracture, and depressed fracture (1 point each) and infratentorial lesion (3 points). CONCLUSIONS AND CLINICAL RELEVANCE The findings reported here may assist in determining prognoses for other dogs with head trauma. The developed scale may be useful for outcome assessment of dogs with head trauma; however, it must be validated before clinical application.
Cranial suture complexity in caviomorph rodents (Rodentia; Ctenohystrica).
Buezas, Guido; Becerra, Federico; Vassallo, Aldo
2017-08-01
Due to their flexibility, sutures are regions that experience greater strains than the surrounding rigid cranial bones. Cranial sutures differ in their degree of interdigitation or complexity. There is evidence indicating that a more convoluted suture better enables the absorption of high stresses coming from dynamic masticatory forces, and other functions. The Order Rodentia is an interesting clade to study this because of its taxa with diverse chewing modes. Due to repeated loading resulting from gnawing and grinding, energy absorption by the sutures might be a crucial factor in these mammals. Species within the infraorder Caviomorpha were chosen as a case study because of their ecomorphological and dietary diversity. This study compared five sutures from the rostrum and cranial vault across seven caviomorph families, and assessed their complexity by means of the relative length and fractal dimension. Across these rodents, cranial sutures are morphologically quite diverse. We found that the sutures connecting the rostrum with the vault were relatively more interdigitated than those in the cranial vault itself, especially premaxillofrontal sutures. Suture interdigitation was higher in species that display chisel-tooth digging and burrowing behaviors, especially in the families Ctenomyidae and Octodontidae, than those in families Dasyproctidae and Cuniculidae, which have more gracile masticatory systems. The reconstruction of the ancestral character state, on family and species phylogeny, points toward low suture interdigitation (i.e., low length ratio) as a likely ancestral state for interfrontal, premaxillofrontal and maxillofrontal sutures. Interspecific differences in suture morphology shown here might represent adaptations to different mechanical demands (i.e., soft vs. tough foods) or behaviors (e.g., chisel-tooth digging), which evolved in close association with the diverse environments occupied by caviomorph rodents. © 2017 Wiley Periodicals, Inc.
95. View of transmitter building no. 102 second floor view ...
95. View of transmitter building no. 102 second floor view of capacitor vaults, waveguides and combiner bifurcation, Official photograph BMEWS Project by C. Henry, 6 January 1962, Photographic Services, Riverton, NJ, BMEWS, clear as negative no. A-3541. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
NUMERICAL FLOW AND TRANSPORT SIMULATIONS SUPPORTING THE SALTSTONE FACILITY PERFORMANCE ASSESSMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flach, G.
2009-02-28
The Saltstone Disposal Facility Performance Assessment (PA) is being revised to incorporate requirements of Section 3116 of the Ronald W. Reagan National Defense Authorization Act for Fiscal Year 2005 (NDAA), and updated data and understanding of vault performance since the 1992 PA (Cook and Fowler 1992) and related Special Analyses. A hybrid approach was chosen for modeling contaminant transport from vaults and future disposal cells to exposure points. A higher resolution, largely deterministic, analysis is performed on a best-estimate Base Case scenario using the PORFLOW numerical analysis code. a few additional sensitivity cases are simulated to examine alternative scenarios andmore » parameter settings. Stochastic analysis is performed on a simpler representation of the SDF system using the GoldSim code to estimate uncertainty and sensitivity about the Base Case. This report describes development of PORFLOW models supporting the SDF PA, and presents sample results to illustrate model behaviors and define impacts relative to key facility performance objectives. The SDF PA document, when issued, should be consulted for a comprehensive presentation of results.« less
Annede, Pierre; Gouy, Sébastien; Mazeron, Renaud; Bentivegna, Enrica; Maroun, Pierre; Petit, Claire; Dumas, Isabelle; Leary, Alexandra; Genestie, Catherine; Lhommé, Catherine; Deutsch, Eric; Morice, Philippe; Pautier, Patricia; Haie‐Meder, Christine
2017-01-01
Abstract Purpose. The phase III European Organization for Research and Treatment of Cancer 55874 study has shown that external beam radiotherapy (EBRT) given as adjuvant treatment decreased locoregional recurrences from 40% to 20% in patients (pts) with localized uterine sarcomas (US). No data exist, however, on the place of brachytherapy (BT). Material and Methods. We conducted a single‐center retrospective analysis of pts receiving adjuvant BT of the vaginal vault based on the vaginal mold technique as part of their multimodal adjuvant treatment for a high‐grade US from 1985 to 2015. Treatment characteristics, patterns of relapse, and toxicity were examined. Results. Median follow‐up time was 5.5 years. A total of 98 pts with high‐grade US were identified: 81 leiomyosarcomas and 17 undifferentiated sarcomas. Postoperative chemotherapy was delivered in 53 pts. Median dose of EBRT was 45 Gy in 25 fractions. High‐dose rate, low‐dose rate, and pulsed‐dose rate techniques were used in 66, 31, and 1 pts, respectively. At last follow‐up, six pts (6.1%) experienced a locoregional relapse as first event. The International Federation of Gynecology and Obstetrics stage and the tumor size were associated with a higher probability of local relapse. When focusing on pts with stage I‐III disease, 5‐year overall survival was 77% (95% confidence interval: 67%–87%) and 5‐year survival without locoregional failure was 91% (83%–98%). Toxicities were mild to moderate, with only four acute grade 3 toxicities and two grade 3 late effects. Conclusion. Vaginal vault BT as part of a multimodal adjuvant treatment was associated with a high locoregional control rate and with acceptable side effects in localized high‐grade US. Implications for Practice. This study suggests that an aggressive adjuvant treatment combining chemotherapy and pelvic external beam radiotherapy followed with a brachytherapy of the vaginal vault is associated with a high locoregional control rate and an acceptable toxicity rate in patients with high grade uterine sarcoma. Adding a brachytherapy boost could also allow deescalating the total dose of pelvic external beam radiotherapy, in order to decrease the side effects of adjuvant treatment in these patients without increasing the risk of local relapse. However, the prognosis remains determined by a high frequency of systemic relapses. PMID:28174295
2015-09-01
associated duct banks and electrical components, and an airfield lighting vault are required. 1.3 SCOPE OF THE EA This EA evaluates the potential impacts on...Taxiway Whiskey. The east side work includes constructing an access road to serve the vault and installing a new 80-way duct bank connecting the east...Maryland September 2015 2-3 the East Runway and Taxiway Echo. On the west side of the airfield the duct bank servicing the airfield would be relocated
Kadam, Pratima Datta; Chuan, Han How
2016-03-01
There was an oversight in the Authorship of a recent Images in Urogynecology article titled: Rectocutaneous fistula with transmigration of the suture: a rare delayed complication of vault fixation with the sacrospinous ligament (DOI 10.1007/ s00192-015-2823-5). We would like to include Adj A/P Han How Chuan’s name in the list of authors. Adj A/P Han is a Senior Consultant and Department Head of Urogynaecology at the KK Hospital for Women and Children, Singapore.
2010-06-28
average Quiet Sun radiance measured at Earth as we did for the first flight. For the VAULT Quiet Sun level we used the peak of the histogram of the...region, and considering the median value for each pixel in time (from Figure 1): Quiet Sun (blue line): We select a region around the lower right...prominences, while the high end reaches the plage levels. Scattered around this Quiet Sun we find several cases of localized brightenings which may be
POLE.VAULT: A Semantic Framework for Health Policy Evaluation and Logical Testing.
Shaban-Nejad, Arash; Okhmatovskaia, Anya; Shin, Eun Kyong; Davis, Robert L; Buckeridge, David L
2017-01-01
The major goal of our study is to provide an automatic evaluation framework that aligns the results generated through semantic reasoning with the best available evidence regarding effective interventions to support the logical evaluation of public health policies. To this end, we have designed the POLicy EVAlUation & Logical Testing (POLE.VAULT) Framework to assist different stakeholders and decision-makers in making informed decisions about different health-related interventions, programs and ultimately policies, based on the contextual knowledge and the best available evidence at both individual and aggregate levels.
Analysis of the Proposed Use of Minuteman Missile Combat Crew Members as Maintenance Extenders.
1984-09-01
which was actually closed and secured after duty hours by a large bank vault-type door. D022. Acronym for the Plans and Intelligence Division, a DO...was secured with a bank vault-type door. 12 p I I I Maintenance I I----lt --u ----ty I -- -- I Training I I Mantenance I I I OHMS I FMMS...adding more duties? Are you crazy? -. OHMS Shop Chiefs .. every time I go down to the LCC the MCCMs are sitting around in their pajamas reading dirty
Radiological performance assessment for the E-Area Vaults Disposal Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, J.R.
This report is the first revision to ``Radiological Performance Assessment for the E-Area Vaults Disposal Facility, Revision 0'', which was issued in April 1994 and received conditional DOE approval in September 1994. The title of this report has been changed to conform to the current name of the facility. The revision incorporates improved groundwater modeling methodology, which includes a large data base of site specific geotechnical data, and special Analyses on disposal of cement-based wasteforms and naval wastes, issued after publication of Revision 0.
Hui, Qianru; Wang, Mian; Wang, Pei; Ma, Ya; Gu, Zhenxin; Yang, Runqiang
2018-01-01
Phytic acid as a phosphorus storage vault provides phosphorus for plant development. It is an anti-nutritional factor for humans and some animals. However, its degradation products lower inositol phosphates have positive effects on human health. In this study, the effect of gibberellic acid (GA) on phytic acid degradation under calcium lactate (Ca) existence was investigated. The results showed that Ca + GA treatment promoted the growth status, hormone metabolism and phytic acid degradation in germinating soybean. At the same time, the availability of phosphorus, the activity of phytic acid degradation-associated enzyme and phosphoinositide-specific phospholipase C (PI-PLC) increased. However, the relative genes expression of phytic acid degradation-associated enzymes did not vary in accordance with their enzymes activity. The results revealed that GA could mediate the transport and function of calcium and a series of physiological and biochemical changes to regulate phytic acid degradation of soybean sprouts. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Robleda, P. G.; Caroti, G.; Martínez-Espejo Zaragoza, I.; Piemonte, A.
2016-06-01
Sometimes it is difficult to represent "on paper" the existing reality of architectonic elements, depending on the complexity of his geometry, but not only in cases with complex geometries: non-relief surfaces, can need a "special planar format" for its graphical representation. Nowadays, there are a lot of methods to obtain tridimensional recovery of our Cultural Heritage with different ranges of the relationship accuracy / costs, even getting high accuracy using "low-cost" recovery methods as digital photogrammetry, which allow us easily to obtain a graphical representation "on paper": ortho-images of different points of view. This can be useful for many purposes but, for others, an orthographic projection is not really very interesting. In non-site restoration tasks of frescoed vaults, a "planar format" representation in needed to see in true magnitude the paintings represented on the intrados vault, because of the general methodology used: gluing the fresco on a fabric, removing the fresco-fabric from the support, moving to laboratory, removing the fresco from the fabric, restoring the fresco, gluing back the restored fresco on another fabric, laying the restored fresco on the original location and removing the fabric. Because of this, many times, an unfolded model is needed, in a similar way a cylinder or cone can be unfolded, but in this case with a texture included: UV unwrapping. Unfold and fold-back processes, can be especially interesting in restoration field of frescoed vaults and domes at: chromatic recovery of paintings, reconstruction of partially missed geometries, transference of paintings on surfaces, etc.
Linden, Olivia E; Baratta, Vanessa M; Gonzalez, Jose A; Byrne, Margaret E; Klinge, Petra M; Sullivan, Stephen R; Taylor, Helena O
2018-01-01
To evaluate 3-dimensional (3-D) photogrammetry as a tool for assessing the postoperative head shape of patients who had undergone cranial vault remodeling for metopic synostosis. We prospectively analyzed images of patients with metopic craniosynostosis who had undergone anterior cranial vault remodeling and age-matched controls. To ensure standardized facial orientation, each 3-D image was positioned to "best fit" the preoperative face by aligning 6 soft tissue landmarks. Forehead measurements were taken from a standardized position behind the surface of the face to landmarks placed in a ray configuration across the forehead. Academic teaching hospital. Thirteen pediatric patients with metopic craniosynostosis who had undergone anterior cranial vault remodeling and age-matched controls. Images were taken preoperatively, immediately postoperatively, and over 1-year postoperatively. Forehead contours preoperatively and postoperatively, with statistics performed using a multivariate analysis of variance shape analysis. Mean postoperative follow-up was 1.8 (0.6) years. The average distance from the origin to forehead landmarks was 55.1 (3.4) mm preoperatively, 59.3 (0.7) mm immediate postoperatively, 59.1 (1.0) mm 1-year postoperatively, and 59.4 (0.6) mm in controls. Postoperative metopic forehead contours varied significantly from preoperative contours ( P < .01), while there was no statistical difference between the 2 postoperative time points ( P = .70). One-year postoperative patients were not significantly different from their age-matched controls ( P > .99). Preoperative metopic forehead contours varied significantly from postoperative contours. Cranial reconstructions approximated the foreheads of normal controls, and reconstructions were stable at more than 1-year follow-up.
Four-year Follow-up of the Changes in Anterior Segment After Phakic Collamer Lens Implantation.
Lu, Yuanyuan; Yang, Na; Li, Xuedong; Kong, Jun
2017-06-01
To assess the changes and relationship in central vaulting, flare intensity, and crystalline lens thickness during a follow-up period of 4 years after implantable collamer lens (ICL) implantation in eyes with high myopia. Retrospective observational study. Ninety-eight eyes of 50 patients were followed up with routine measurements of central vaulting, crystalline lens thickness, endothelial cell density, and aqueous flare postoperatively. Data were analyzed by repeated-measures analysis of variance. The relationship between the annual change in crystal lens thickness after surgery and age was evaluated by Pearson correlation coefficient and linear regression. There was a continuous reduction in central vaulting and endothelial cell density as well as an increase in crystalline lens thickness in ICL eyes from 1 month onward to 5 years postoperatively (P < .001). Although the trend of variation during the individual visit period was accentuated, the variation turned out to be smaller between 12 and 36 months or 60 months postoperatively (P = .42, P = .65). Aqueous flare intensity increased significantly after surgery and returned to normal 1 year later. Additionally, a positive correlation between patient age and crystalline lens thickness (r = 0.617, P < .0001) was observed in eyes with ICL implantation. The changes in central vaulting, endothelial cell density, and crystalline lens thickness are more prominent during the first year after ICL implantation, tending to be relatively stable afterwards. The anterior inflammation during the early postoperative period synchronizes with the sharp progression of crystalline lens changes within the first year. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Chintzoglou, Georgios; De Pontieu, Bart; Martínez-Sykora, Juan; Pereira, Tiago M. D.; Vourlidas, Angelos; Tun Beltran, Samuel
2018-04-01
We present results from an observing campaign in support of the VAULT2.0 sounding rocket launch on 2014 September 30. VAULT2.0 is a Lyα (1216 Å) spectroheliograph capable of providing spectroheliograms at high cadence. Lyα observations are highly complementary to the IRIS observations of the upper chromosphere and the low transition region (TR) but have previously been unavailable. The VAULT2.0 data provide new constraints on upper-chromospheric conditions for numerical models. The observing campaign was closely coordinated with the IRIS mission. Taking advantage of this simultaneous multi-wavelength coverage of target AR 12172 and by using state-of-the-art radiative-MHD simulations of spicules, we investigate in detail a type-II spicule associated with a fast (300 km s‑1) network jet recorded in the campaign observations. Our analysis suggests that spicular material exists suspended high in the atmosphere but at lower temperatures (seen in Lyα) until it is heated and becomes visible in TR temperatures as a network jet. The heating begins lower in the spicule and propagates upwards as a rapidly propagating thermal front. The front is then observed as fast, plane-of-the-sky motion typical of a network jet, but contained inside the pre-existing spicule. This work supports the idea that the high speeds reported in network jets should not be taken as real mass upflows but only as apparent speeds of a rapidly propagating heating front along the pre-existing spicule.
Modeling of Near-Surface Leakage and Seepage of CO2 for Risk Characterization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oldenburg, Curtis M.; Unger, Andre A.J.
2004-02-18
The injection of carbon dioxide (CO2) into deep geologic carbon sequestration sites entails risk that CO2 will leak away from the primary storage formation and migrate upwards to the unsaturated zone from which it can seep out of the ground. We have developed a coupled modeling framework called T2CA for simulating CO2 leakage and seepage in the subsurface and in the atmospheric surface layer. The results of model simulations can be used to calculate the two key health, safety, and environmental (HSE) risk drivers, namely CO2 seepage flux and nearsurface CO2 concentrations. Sensitivity studies for a subsurface system with amore » thick unsaturated zone show limited leakage attenuation resulting in correspondingly large CO2 concentrations in the shallow subsurface. Large CO2 concentrations in the shallow subsurface present a risk to plant and tree roots, and to humans and other animals in subsurface structures such as basements or utility vaults. Whereas CO2 concentrations in the subsurface can be high, surfacelayer winds reduce CO2 concentrations to low levels for the fluxes investigated. We recommend more verification and case studies be carried out with T2CA, along with the development of extensions to handle additional scenarios such as calm conditions, topographic effects, and catastrophic surface-layer discharge events.« less
Obed, Rachel Ibhade; Akinlade, Bidemi Idayat; Ntekim, Atara
2015-01-01
Purpose In-vivo measurements to determine doses to organs-at-risk can be an essential part of brachytherapy quality assurance (QA). This study compares calculated doses to the rectum with measured dose values as a means of QA in vaginal vault brachytherapy using cylinder applicators. Material and methods At the Department of Radiotherapy, University College Hospital (UCH), Ibadan, Nigeria, intracavitary brachytherapy (ICBT) was delivered by a GyneSource high-dose-rate (HDR) unit with 60Co. Standard 2D treatment plans were created with HDR basic 2.6 software for prescription doses 5-7 Gy at points 5 mm away from the posterior surface of vaginal cylinder applicators (20, 25, and 30 mm diameters). The LiF:Mg, Ti thermoluminescent dosimeter rods (1 x 6 mm) were irradiated to a dose of 7 Gy on Theratron 60Co machine for calibration purpose prior to clinical use. Measurements in each of 34 insertions involving fourteen patients were performed with 5 TLD-100 rods placed along a re-usable rectal marker positioned in the rectum. The dosimeters were read in Harshaw 3500 TLD reader and compared with doses derived from the treatment planning system (TPS) at 1 cm away from the dose prescription points. Results The mean calculated and measured doses ranged from 2.1-3.8 Gy and 1.2-5.6 Gy with averages of 3.0 ± 0.5 Gy and 3.1 ± 1.1 Gy, respectively, for treatment lengths 2-8 cm along the cylinder-applicators. The mean values correspond to 48.9% and 50.8% of the prescribed doses, respectively. The deviations of the mean in-vivo doses from the TPS values ranged from –1.9 to 2.1 Gy with a p-value of 0.427. Conclusions This study was part of efforts to verify rectal dose obtained from the TPS during vaginal vault brachytherapy. There was no significant difference in the dose to the rectum from the two methods of measurements. PMID:26816506
NASA Astrophysics Data System (ADS)
Gurrola, H.; Pratt, K. W.; Pulliam, J.; Dunbar, J. A.
2011-12-01
In summer of 2010, 21 broadband seismographs were installed at 16-18 km spacing along a transect running from Johnson City, TX, (on the Edwards Plateau), to Matagorda Island to study the current structure of this rifted passive margin. The large magnetic anomaly that parallels the coast throughout the Gulf region moves on-shore beneath our transect such that we will be able to investigate the source of this anomaly. A second important target that will be imaged in this Balcones fault which is associated with the Ouachita front. This project is funded by a grant from the Norman Hackerman Advanced Research Program (NHARP), a biannual competition among Texas Universities to support research, and makes use of Texas Tech, Baylor, and UT Austin equipment. As a result, the deployment includes a less uniform array of seismic equipment, (10 Trillium compact seismometers and 10 Guralps; including 40Ts, 3Ts and 3ESPs), than projects supported by the IRIS PASSCAL center. Our vault construction was similar to Flexible array vaults, but Gulf Coast provides a more challenging environment for deployment than most encountered in the western US. The shallow water table and loose sediment can become almost fluid when storms deluge the area with rain. In dry periods, mud cracks near the vaults cause the vaults to tilt. As a result, even high quality, shallow seismic vaults can "float" or shift sufficiently to cause one or two components of the seismic stations to drift against their stops in days or weeks. As a result, the only data consistently available from all our stations, are vertical components. Horizontal component data from the summer of 2010 can be hit and miss due to the tilting of the vaults. These issues have been reduced in the summer of 2011 due to the drought. To address the data's shortcomings, we will average the vertical components from our stations and nearby EarthScope TA stations, (up 300 km away), to isolate the cleanest representation of the incoming P-wave, (with local PPp reverberations averaged out). This is essentially beam forming for the optimal teleseismic ray path. The clean P-wave will then be deconvolved from the vertical components at each station to produce a vertical component receiver function that will enable us to model and stack local P-wave reverberations to produce a 2-D image of lithospheric structure. To produce traditional receiver functions from time periods where one component is lost from several stations, we will treat neighboring stations as arrays and recover an "array averaged three-component seismogram" for each loacation. These "beamed" seismograms will allow imaging of the crust, lithospheric mantle, and transition zone beneath the broadband array using traditional receiver function stacking or migration.
Review of Concrete Biodeterioration in Relation to Buried Nuclear Waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turick, C; Berry, C.
Long-term storage of low level radioactive material in below ground concrete disposal units (DUs) (Saltstone Disposal Facility) is a means of depositing wastes generated from nuclear operations of the U.S. Department of Energy. Based on the currently modeled degradation mechanisms, possible microbial induced effects on the structural integrity of buried low level wastes must be addressed. Previous international efforts related to microbial impacts on concrete structures that house low level radioactive waste showed that microbial activity can play a significant role in the process of concrete degradation and ultimately structural deterioration. This literature review examines the recent research in thismore » field and is focused on specific parameters that are applicable to modeling and prediction of the fate of concrete vaults housing stored wastes and the wastes themselves. Rates of concrete biodegradation vary with the environmental conditions, illustrating a need to understand the bioavailability of key compounds involved in microbial activity. Specific parameters require pH and osmotic pressure to be within a certain range to allow for microbial growth as well as the availability and abundance of energy sources like components involved in sulfur, iron and nitrogen oxidation. Carbon flow and availability are also factors to consider in predicting concrete biodegradation. The results of this review suggest that microbial activity in Saltstone, (grouted low level radioactive waste) is unlikely due to very high pH and osmotic pressure. Biodegradation of the concrete vaults housing the radioactive waste however, is a possibility. The rate and degree of concrete biodegradation is dependent on numerous physical, chemical and biological parameters. Results from this review point to parameters to focus on for modeling activities and also, possible options for mitigation that would minimize concrete biodegradation. In addition, key chemical components that drive microbial activity on concrete surfaces are discussed.« less
Geoffrion, Roxana; Hyakutake, Momoe T; Koenig, Nicole A; Lee, Terry; Cundiff, Geoffrey W
2015-02-01
Bilateral sacrospinous fixation with tailored mesh arms (bSSVF) uses polypropylene mesh to suspend the vault to the sacrospinous ligaments bilaterally with minimal tension, recreating nulliparous midline anatomy. It can be used with uterine conservation. Our primary objective was to determine objective cure rate at one year following bSSVF compared with a control group undergoing abdominal sacrocolpopexy (ASC). Secondary objectives were to compare symptoms, quality of life, sexual function, pain, and global satisfaction before and after surgery and between bSSVF and ASC groups at one year. This prospective cohort study enrolled patients with symptomatic prolapse who chose to undergo bSSVF or ASC. Baseline demographics were obtained. Prolapse quantification, validated symptom questionnaire scores, and McGill pain scores were obtained at baseline, six weeks, and one-year postoperatively. Global satisfaction was recorded. The primary outcome measure was the difference in cure rate (vault stage ≤ 1) between groups. Fifty patients were recruited: 30 underwent bSSVF and 17 ASC. Forty-three patients were available for one-year follow-up. Baseline data were similar. There was no difference in vault stage between bSSVF and ASC groups at one year. Five women who underwent bSSVF had cervical elongation, and four of these were classified as POP recurrence. Women who underwent bSSVF had more anterior recurrences but fewer postoperative complications, shorter hospital stay, and less use of narcotics than controls. Questionnaire scores were similar at one year. All respondents felt subjective improvement after either surgical procedure. Objective and subjective cure rates are comparable after bSSVF and ASC. Hysteropexy may cause cervical elongation that merits further research.
Çağıcı, Can Alper
2017-11-16
Following nasal hump removal during septorhinoplasty, the middle vault should be reconstructed to avoid functional and esthetic problems. Middle vault reconstruction, however, may result in widening of the middle vault and may need a camouflage graft to cover dorsal irregularities. To present the results of reconstructing the middle vault with a technique that covers the nasal dorsum with upper lateral cartilage, from the viewpoint of patient satisfaction. Retrospective study of patients who underwent septorhinoplasty that included nasal dorsum closure with upper lateral cartilage from December 1, 2014 to January 31, 2016. Those with postoperative follow-up of less than 3 months were excluded. The final study group included 39 patients. The same surgeon performed all septorhinoplasties. The dorsum was closed using an "upper lateral closing" technique that approximated upper lateral cartilages to each other over the septum. Postoperative patient satisfaction was determined using a visual analog scale and the rhinoplasty outcomes evaluation questionnaire. The questionnaire evaluates patient esthetic and functional satisfaction with the operated nose. High scores indicate improved esthetic results. No dorsal irregularities were seen at postoperative follow-up evaluation of the patients. For esthetic nasal appearance, the median visual analogue scale scores was 86%, and the mean for the questionnaire was 77.03%. The natural dome-shaped anatomy of the nasal dorsum was achieved by approximating the upper lateral cartilages to each other. Closing the dorsum with this technique also covers any dorsal irregularities and results in a smooth dorsum. Patients expressed satisfaction with the esthetic and functional aspects of the smooth, attractive nasal dorsum. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Gupta, Sanjay; Sodhani, Pushpa; Singh, Veena; Sehgal, Ashok
2013-09-01
The study was undertaken to assess the utility of cervico-vaginal/vault cytology in the follow-up of women treated for cervical cancer and benign gynecological conditions. Records of 3,523 cervico-vaginal smears from 2,658 women who underwent hysterectomy and/or radiotherapy or chemotherapy, over a 10-year period were retrieved. Data was collected on type of treatment received, indication for hysterectomy, age of patient, presenting symptoms, stage of tumor, interval since treatment, cytology and biopsy results. The results of cytology versus other parameters were analyzed separately for women treated for cervical cancer and those hysterectomized for benign indications. Malignant cells were detected in 141/1949 (7.2%) follow-up smears from treated cervical cancer cases (140 recurrences and 1 VAIN). Around 92% of recurrences of cervical cancer were detected with in 2 years of follow-up and 75% of these women were symptomatic. Cytology first alerted the clinicians to a recurrence in a quarter of cases. On the other hand, VAIN was detected in 5/1079 (0.46%) vault smears from 997 women hysterectomized for benign gynecologic disease. All these women were asymptomatic and majority (80%) were detected in follow-up smears performed between 3 and 10 years. Vault cytology is an accurate tool to detect local recurrences/VAIN in women treated for cervical cancer or benign gynecological conditions. It may even first alert the clinicians to a possibility of recurrence. However, due to extremely low prevalence of VAIN/vaginal cancer, it seems unwarranted in women hysterectomized for benign indications, especially in resource constrained settings. Copyright © 2012 Wiley Periodicals, Inc., a Wiley company.
NASA Astrophysics Data System (ADS)
Tanny, Sean
The advent of high-energy linear accelerators for dedicated medical use in the 1950's by Henry Kaplan and the Stanford University physics department began a revolution in radiation oncology. Today, linear accelerators are the standard of care for modern radiation therapy and can generate high-energy beams that can produce tens of Gy per minute at isocenter. This creates a need for a large amount of shielding material to properly protect members of the public and hospital staff. Standardized vault designs and guidance on shielding properties of various materials are provided by the National Council on Radiation Protection (NCRP) Report 151. However, physicists are seeking ways to minimize the footprint and volume of shielding material needed which leads to the use of non-standard vault configurations and less-studied materials, such as high-density concrete. The University of Toledo Dana Cancer Center has utilized both of these methods to minimize the cost and spatial footprint of the requisite radiation shielding. To ensure a safe work environment, computer simulations were performed to verify the attenuation properties and shielding workloads produced by a variety of situations where standard recommendations and guidance documents were insufficient. This project studies two areas of concern that are not addressed by NCRP 151, the radiation shielding workload for the vault door with a non-standard design, and the attenuation properties of high-density concrete for both photon and neutron radiation. Simulations have been performed using a Monte-Carlo code produced by the Los Alamos National Lab (LANL), Monte Carlo Neutrons, Photons 5 (MCNP5). Measurements have been performed using a shielding test port designed into the maze of the Varian Edge treatment vault.
Lai, Hongpeng; Wang, Shuyong; Xie, Yongli
2016-01-01
In the New Qidaoliang Tunnel (China), a rear-end collision of two tanker trunks caused a fire. To understand the damage characteristics of the tunnel lining structure, in situ investigation was performed. The results show that the fire in the tunnel induced spallation of tunnel lining concrete covering 856 m3; the length of road surface damage reached 650 m; the sectional area had a maximum 4% increase, and the mechanical and electrical facilities were severely damaged. The maximum area loss happened at the fire spot with maximum observed concrete spallation up to a thickness of 35.4 cm. The strength of vault and side wall concrete near the fire source was significantly reduced. The loss of concrete strength of the side wall near the inner surface of tunnel was larger than that near the surrounding rock. In order to perform back analysis of the effect of thermal load on lining structure, simplified numerical simulation using computational fluid dynamics (CFD) was also performed, repeating the fire scenario. The simulated results showed that from the fire breaking out to the point of becoming steady, the tunnel experienced processes of small-scale warming, swirl around fire, backflow, and longitudinal turbulent flow. The influence range of the tunnel internal temperature on the longitudinal downstream was far greater than on the upstream, while the high temperature upstream and downstream of the transverse fire source mainly centered on the vault or the higher vault waist. The temperature of each part of the tunnel near the fire source had no obvious stratification phenomenon. The temperature of the vault lining upstream and downstream near the fire source was the highest. The numerical simulation is found to be in good agreement with the field observations. PMID:27754455
Lai, Hongpeng; Wang, Shuyong; Xie, Yongli
2016-10-15
In the New Qidaoliang Tunnel (China), a rear-end collision of two tanker trunks caused a fire. To understand the damage characteristics of the tunnel lining structure, in situ investigation was performed. The results show that the fire in the tunnel induced spallation of tunnel lining concrete covering 856 m³; the length of road surface damage reached 650 m; the sectional area had a maximum 4% increase, and the mechanical and electrical facilities were severely damaged. The maximum area loss happened at the fire spot with maximum observed concrete spallation up to a thickness of 35.4 cm. The strength of vault and side wall concrete near the fire source was significantly reduced. The loss of concrete strength of the side wall near the inner surface of tunnel was larger than that near the surrounding rock. In order to perform back analysis of the effect of thermal load on lining structure, simplified numerical simulation using computational fluid dynamics (CFD) was also performed, repeating the fire scenario. The simulated results showed that from the fire breaking out to the point of becoming steady, the tunnel experienced processes of small-scale warming, swirl around fire, backflow, and longitudinal turbulent flow. The influence range of the tunnel internal temperature on the longitudinal downstream was far greater than on the upstream, while the high temperature upstream and downstream of the transverse fire source mainly centered on the vault or the higher vault waist. The temperature of each part of the tunnel near the fire source had no obvious stratification phenomenon. The temperature of the vault lining upstream and downstream near the fire source was the highest. The numerical simulation is found to be in good agreement with the field observations.
Delas, Suncica; Babin, Josip; Katić, Ratko
2007-12-01
In order to identify biomotor systems that determine performance of competitive gymnastics elements in elementary school female sixth-graders, factor structures of morphological characteristics and basic motor abilities were determined first, followed by relations of the morphological-motor system factors obtained with a set of criterion variables evaluating specific motor skills in competitive gymnastics in 126 female children aged 12 years +/- 3 months. Factor analysis of 17 morphological measures yielded three morphological factors: factor of mesoendomorphy and/or adipose body voluminosity; factor of longitudinal body dimensionality; and factor of transverse arm dimensionality. Factor analysis of 16 motor variables produced four motor factors: general motoricity factor (motor system); general speed factor; factor of explosive strength of throwing type (arm explosiveness); and factor of arm and leg flexibility. Three significant canonical correlations, i.e. linear combinations, explained the association between the set of seven latent variables of the morphological and basic motor system, and five variables evaluating the knowledge in competitive gymnastics. The first canonical linear combination was based on a favorable and predominant impact of the general motor factor (a system integrating whole body coordination, leg explosiveness, relative arm strength, arm movement frequency and body flexibility) on performance of gymnastics elements, cartwheel, handstand and backward pullover mount in particular, and to a lesser extent front scale and double leg pirouette for 180 degrees. The relation of the second pair of canonical factors additionally explained the role of transverse dimensionality of arm skeleton, arm flexibility and explosiveness in performing cartwheel and squat vault, whereas the relation of the third pair of canonical factors explained the unfavorable impact of adipose voluminosity on the performance of squat vault and backward pullover mount.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, John A.; Burke, Kevin J.; Looman, Marc R.
2012-07-01
This paper describes the development, testing and validation of a waste measurement instrument for characterising active remote handled radioactive waste arising from the operation of Magnox reactors in the United Kingdom. Following operation in UK Magnox gas cooled reactors and a subsequent period of cooling, parts of the magnesium-aluminium alloy cladding were removed from spent fuel and the uranium fuel rods with the remaining cladding were removed to Sellafield for treatment. The resultant Magnox based spent fuel element debris (FED), which constitutes active intermediate level waste (ILW) has been stored in concrete vaults at the reactor sites. As part ofmore » the decommissioning of the FED vaults the FED must be removed, measured and characterised and placed in intermediate storage containers. The present system was developed for use at the Trawsfynydd nuclear power station (NPS), which is in the decommissioning phase, but the approach is potentially applicable to FED characterisation at all of the Magnox reactors. The measurement system consists of a heavily shielded and collimated high purity Germanium (HPGe) detector with electromechanical cooling and a high count-rate preamplifier and digital multichannel pulse height analyser. The HPGe based detector system is controlled by a software code, which stores the measurement result and allows a comprehensive analysis of the measured FED data. Fuel element debris is removed from the vault and placed on a tray to a uniform depth of typically 10 cm for measurement. The tray is positioned approximately 1.2 meters above the detector which views the FED through a tungsten collimator with an inverted pyramid shape. At other Magnox sites the positions may be reversed with the shielded and collimated HPGe detector located above the tray on which the FED is measured. A comprehensive Monte Carlo modelling and analysis of the measurement process has been performed in order to optimise the measurement geometry and eliminate interferences from radioactive sources and FED in the immediate vicinity of the measurement position. The detector system has been calibrated and high activity radioactive sources of Cs-137, Co-60 and Na-22 have been used to validate the measurement process. The data acquisition and analysis software code has been tested and validated in keeping with the software quality assurance requirements of both ISO:9001-2008 - TICK-IT in the UK and NQA-1. The measurement and analysis system has been comprehensively tested with high activity sources, is flexible and may be applicable to a wide range of remote handled radioactive waste measurement applications. It is due to be installed at Trawsfynydd NPS later this year. This paper describes the Waste Tray Assay System (WTAS) that has been developed for the measurement of Magnox FED waste. The WTAS has been tested with a range of radioactive sources and its operation has been simulated with benchmarked MCNP Monte Carlo calculations. The measurement software has been validated as has the operation of the system for a range of strong radioactive sources. A system based on the design is due for installation and operation in 2012. The system has application to the measurement of Magnox Fuel Element Debris (FED) waste at other Magnox reactor sites. The major design objective of the WTAS that has been achieved is the ability of the assay system to determine the content of Cs-137, and in turn to enable the fissile burden to be assessed using a radionuclide fingerprint, in the presence of higher and highly variable quantities of Co-60, typically from nimonic springs. The approach can be used in other Magnox FED waste configurations where the detector is located above the FED waste sorting tray and where the collimation is fixed below the detector and at a distance above the tray. In this case, which has also been investigated, there are different shielding problems and mechanical support issues. The extensive use of MCNP Monte Carlo modelling to simulate the geometry of the sorting cell and the distribution of radioactive sources has helped to ensure that all of the detector shielding requirements are addressed and suitable Cs-137 and Co-60 discrimination can be achieved. The WTAS in its present form or in other configurations has relevance to the measurement of other active ILW and highly active RH waste. Examples include high activity RH LLW and RH TRU (Transuranic) waste as defined in the United States arising from both commercial nuclear and Department of Energy (DOE) operations. The analysis is able to analyse a range of radionuclides beyong those expected in the Magnox FED cases. (authors)« less
SCM Paste Samples Exposed To Aggressive Solutions. Cementitious Barriers Partnership
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foster, T.
This report summarizes experimental work performed by SIMCO Technologies Inc. (SIMCO) as part of the Cementitious Barriers Partnership (CBP) project. The test series followed an experimental program dedicated to the study of ordinary Portland cement (OPC) hydrated cement pastes exposed to aggressive solutions. In the present study, the scope is extended to hydrated cement pastes incorporating supplementary cementitious materials (SCM) such as fly ash and ground granulated blast furnace slag (GGBFS). Also, the range of aggressive contact solutions was expanded. The experimental program aimed at testing aggressive contact solutions that more closely mimic the chemical composition of saltstone pore solution.more » Five different solutions, some of which incorporated high levels of carbonate and nitrate, were placed in contact with four different hydrated cement paste mixes. In all solutions, 150 mmol/L of SO 4 2– (14 400 ppm) were present. The solutions included different pH conditions and different sodium content. Two paste mixes were equivalent to Vault 1/4 and Vault 2 concrete mixes used at SRS in storage structures. Two additional paste mixes, cast at the same water-to-cement ratio and using the same cements but without SCMs, were also tested. The damage evolution in samples was monitored using ultrasonic pulse velocity (UPV) and mass measurements. After three and twelve months of exposure conditions, samples were taken out of solution containers and analyzed to perform migration tests and porosity measurements. Globally, results were in line with the previous study and confirmed that high pH may limit the formation of some deleterious phases like gypsum. In this case, ettringite may form but is not necessarily associated with damage. However, the high concentration of sodium may be associated with the formation of an AFm-like mineral called U-phase. The most significant evidences of damage were all associated with the Vault 2 paste analog. This material proved very sensitive to high pH. All measurement techniques used to monitor and evaluate damage to samples indicated significant alterations to this mix when immersed in contact solutions containing sodium hydroxide. It was hypothesized that the low cement content, combined with high silica content coming from silica fume, fly ash and GGBFS led to the presence unreacted silica. It is possible that the pozzolanic reaction of these SCMs could not be activated due to the low alkali content, a direct consequence of low cement content. In this scenario, the material end up having a lot of silica available to react upon contact with sodium hydroxide, possibly forming a gel that may be similar to the gel formed in alkali-silica reactions. This scenario needs further experimental confirmation, but it may well explain the poor behavior of mix PV2 in presence of NaOH.« less
Sensor emplacement testing at Poker Flat, Alaska
NASA Astrophysics Data System (ADS)
Reusch, A.; Beaudoin, B. C.; Anderson, K. E.; Azevedo, S.; Carothers, L.; Love, M.; Miller, P. E.; Parker, T.; Pfeifer, M.; Slad, G.; Thomas, D.; Aderhold, K.
2013-12-01
PASSCAL provides equipment and support for temporary seismic projects. Speed and efficiency of deployments are essential. A revised emplacement technique of putting broadband sensors directly into soil (aka direct burial) is being tested. The first phase (fall 2011 to spring 2013) comparing data quality and sensor stability between the direct burial and the traditional 1 m deep temporary PASSCAL-style vault in a wet and noisy site near San Antonio, NM is complete. Results suggest there is little or no difference in sensor performance in the relatively high-noise environment of this initial test. The second phase was started in November 2012 with the goal of making the same comparison, but at Poker Flat, Alaska, in a low-noise, high-signal, cold and wet environment, alongside a Transportable Array (TA) deployment to be used as a performance control. This location is in an accessible and secure area with very low site noise. In addition to benefiting future worldwide PASSCAL deployments, the Poker Flat experiment serves a secondary purpose of testing modifications necessary to successfully deploy and recover broadband stations in a cold environment with the limited logistics anticipated for remote Flexible Array (FA) and PASSCAL Program deployments in Alaska. Developing emplacement techniques that maintain high data quality and data return while minimizing logistics is critical to enable principle investigators to effectively and efficiently co-locate within the future TA Alaska footprint. Three Nanometrics sensors were installed in November 2012 in power-augered holes 76 cm in depth: a Trillium Compact Posthole (PH) and two Trillium 120PH units (one standard PH and one enhanced PHQ). The installations took less than 8 hours in -30°C conditions with 4 hours of usable daylight. The Compact PH and the 120PHQ are delivering data in realtime, while the 120PH is testing standalone power and data collection systems. Preliminary results compare favorably to each other as well as the nearby Trillium 240 in a traditional TA surface vault and a 120PH in a 5 m machine-drilled borehole. This summer, two Trillium 120PA sensors were installed at a depth of 54 cm in traditional PASSCAL-style vaults, adjacent to the Trillium Compact PH, Trillium 120PH and 120PHQ emplacements. Analysis of the data collected from these five sensors will include the use of probability density functions of power spectral density to examine temporal trends in noise, signal-to-noise ratios for local, regional, and teleseismic earthquakes, and coherence of both noise and earthquake signal recordings to compare the data quality of direct burial versus temporary PASSCAL-style vaults sensor emplacements.
Cheronet, Olivia; Finarelli, John A; Pinhasi, Ron
2016-09-13
The Neolithic transition brought about fundamental social, dietary and behavioural changes in human populations, which, in turn, impacted skeletal morphology. Crania are shaped through diverse genetic, ontogenetic and environmental factors, reflecting various elements of an individual's life. To determine the transition's effect on cranial morphology, we investigated its potential impact on the face and vault, two elements potentially responding to different influences. Three datasets from geographically distant regions (Ukraine, Iberia, and the Levant plus Anatolia) were analysed. Craniometric measurements were used to compare the morphology of pre-transition populations with that of agricultural populations. The Neolithic transition corresponds to a statistically significant increase only in cranial breadth of the Ukrainian vaults, while facial morphology shows no consistent transformations, despite expected changes related to the modification of masticatory behaviour. The broadening of Ukrainian vaults may be attributable to dietary and/or social changes. However, the lack of change observed in the other geographical regions and the lack of consistent change in facial morphology are surprising. Although the transition from foraging to farming is a process that took place repeatedly across the globe, different characteristics of transitions seem responsible for idiosyncratic responses in cranial morphology.
Shielding evaluation for IMRT implementation in an existing accelerator vault
Price, R. A.; Chibani, O.; Ma, C.‐M.
2003-01-01
A formalism is developed for evaluating the shielding in an existing vault to be used for IMRT. Existing exposure rate measurements are utilized as well as a newly developed effective modulation scaling factor. Examples are given for vaults housing 6, 10 and 18 MV linear accelerators. The use of an 18 MV Siemens linear accelerator is evaluated for IMRT delivery with respect to neutron production and the effects on individual patients. A modified modulation scaling factor is developed and the risk of the incurrence of fatal secondary malignancies is estimated. The difference in neutron production between 18 MV Varian and Siemens accelerators is estimated using Monte Carlo results. The neutron production from the Siemens accelerator is found to be approximately 4 times less than that of the Varian accelerator resulting in a risk of fatal secondary malignancy occurrence of approximately 1.6% when using the SMLC delivery technique and our measured modulation scaling factors. This compares with a previously published value of 1.6% for routine 3D CRT delivery on the Varian accelerator. PACS number(s): 87.52.Ga, 87.52.Px, 87.53.Qc, 87.53.Wz PMID:12841794
Bradshaw, Elizabeth Jane; Hume, Patria Anne; Aisbett, Brad
2012-01-01
We determined the inter-day variability in elite-standard women's artistic gymnastics competition scores. National (50 gymnasts for up to three days) and Olympic (24 gymnasts for up to five days) competition scores published in the public domain ('Giant poster pull-out', 2010 ; Gymnastics Australia, 2008 ) were evaluated using three statistical measures. Analyses of the inter-day differences in the mean scores as a percentage (MDiff%), coefficient of variation percentages for the mean score across both days (CV%), and Pearson correlation coefficients for the inter-day score (r) were interpreted using thresholds from trivial to large. National-class gymnasts' two-day performance variation was trivial for vault, small for floor and beam, and moderate for bars. When senior gymnasts competed for a third day the performance variation increased to moderate for vault. Across five days of Olympic competition there were trivial (e.g. CV%: vault = 0.8) to small (e.g. CV%: bars = 2.0) variations in performances between days on all apparatus. Olympians' performance score consistency is superior to senior, national-class competitors. The performance score consistency required for gymnasts who aspire to participate at the Olympics as a top-24 competitor is better than 3%.
Characterizing local variability in long‐period horizontal tilt noise
Rohde, M.D.; Ringler, Adam; Hutt, Charles R.; Wilson, David; Holland, Austin; Sandoval, L.D; Storm, Tyler
2017-01-01
Horizontal seismic data are dominated by atmospherically induced tilt noise at long periods (i.e., 30 s and greater). Tilt noise limits our ability to use horizontal data for sensitive seismological studies such as observing free earth modes. To better understand the local spatial variability of long‐period horizontal noise, we observe horizontal noise during quiet time periods in the Albuquerque Seismological Laboratory (ASL) underground vault using four small‐aperture array configurations. Each array comprises eight Streckeisen STS‐2 broadband seismometers. We analyze the spectral content of the data using power spectral density and magnitude‐squared coherence (γ2‐coherence). Our results show a high degree of spatial variability and frequency dependence in the long‐period horizontal wavefield. The variable nature of long‐period horizontal noise in the ASL vault suggests that it might be highly local in nature and not easily characterized by simple physical models when overall noise levels are low, making it difficult to identify locations in the vault with lower horizontal noise. This variability could be limiting our ability to apply coherence analysis for estimating horizontal sensor self‐noise and could also complicate various indirect methods for removing long‐period horizontal noise (e.g., collocated rotational sensor or microbarograph).
Ren, Lei; Hutchinson, John R
2007-01-01
We examined whether elephants shift to using bouncing (i.e. running) mechanics at any speed. To do this, we measured the three-dimensional centre of mass (CM) motions and torso rotations of African and Asian elephants using a novel multisensor method. Hundreds of continuous stride cycles were recorded in the field. African and Asian elephants moved very similarly. Near the mechanically and metabolically optimal speed (a Froude number (Fr) of 0.09), an inverted pendulum mechanism predominated. With increasing speed, the locomotor dynamics quickly but continuously became less like vaulting and more like bouncing. Our mechanical energy analysis of the CM suggests that at a surprisingly slow speed (approx. 2.2 m s−1, Fr 0.25), the hindlimbs exhibited bouncing, not vaulting, mechanics during weight support. We infer that a gait transition happens at this relatively slow speed: elephants begin using their compliant hindlimbs like pogo sticks to some extent to drive the body, bouncing over their relatively stiff, vaulting forelimbs. Hence, they are not as rigid limbed as typically characterized for graviportal animals, and use regular walking as well as at least one form of running gait. PMID:17594960
SU-E-T-243: Design of a Novel Testing Port for Radiation Protection and Shielding Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanny, S; Parsai, E; Harrell, D
2015-06-15
Purpose: The majority of radiation shielding research utilizes Monte Carlo simulation because of the difficulty in eliminating secondary radiations from measurements. We have designed a test port into a primary barrier of our newest vault to allow for shielding measurements while ensuring adequate protection to the public and staff during normal machine operation. This port allows for measurement of attenuation values of shielding materials, differential dose albedos, and radiation scatter fractions. Methods: The vault design utilized the maze as part of a compound primary barrier. The test port is contained within the maze and is centered along isocenter. The innermore » 30 cm has a 20×20 cm{sup 2} opening, while the remaining length has a 30×30 cm{sup 2} opening. The block that contains the port has a density of 200 pcf to minimize internal scatter. The 30×30 cm{sup 2} opening is occupied by removable 215 pcf concrete blocks. The innermost and outermost blocks activate an interlock wired into the beam-enable loop. This disallows beam-on in treatment mode if the interlock isn’t closed. The interlock can be overridden in service mode, or by-passed via an override switch in case of circuit failure. Results: The test port was installed in August. The beam is disabled when the interlock is tripped. Measurements taken when the primary beam is not incident on the port are indistinguishable from background. Ambient dose levels surrounding the vault with the designed shielding blocks in place are all within allowable limits for occupational workers. Conclusions: We have designed and installed a unique testing port for radiation protection and shielding measurements. This port is appropriately interlocked and designed to mitigate any risks of incidental exposure to staff or members of the public. The test port design allows measurements with “good geometry” and efficient removal of contaminating sources of radiation present in many shielding measurements. Daniel Harrell and Jim Noller are employees of Shielding Construction Solutions, Inc, the shielding construction company that built the vault discussed in this abstract. Manjit Chopra is an employee of Universal Minerals International, Inc, the company that provided the aggregates for the high density concretes used in the vault construction.« less
Impact of a flattening filter free linear accelerator on structural shielding design.
Jank, Julia; Kragl, Gabriele; Georg, Dietmar
2014-03-01
The present study aimed to assess the effects of a flattening filter free medical accelerator on structural shielding demands of a treatment vault of a medical linear accelerator. We tried to answer the question, to what extent the required thickness of the shielding barriers can be reduced if instead of the standard flattened photon beams unflattened ones are used. We chose both an experimental as well as a theoretical approach. On the one hand we measured photon dose rates at protected places outside the treatment room and compared the obtained results for flattened and unflattened beams. On the other hand we complied with international guidelines for adequate treatment vault design and calculated the shielding barriers according to the therein given specifications. Measurements were performed with an Elekta Precise™ linac providing nominal photon energies of 6 and 10 MV. This machine underwent already earlier some modifications in order to be able to operate both with and without a flattening filter. Photon dose rates were measured with a LB133-1 dose rate meter manufactured by Berthold. To calculate the thickness of shielding barriers we referred to the Austrian standard ÖNORM S 5216 and to the US American NCRP Report No. 151. We determined a substantial photon dose rate reduction for all measurement points and photon energies. For unflattened 6 MV beams a reduction factor ranging from 1.4 to 1.8 was identified. The corresponding values for unflattened 10 MV beams were 2.1 and 3.2. The performed shielding calculations indicated the same tendency: For all relevant radiation components we found a reduction in shielding thickness when unflattened beams were used. The required thickness of primary barriers was reduced up to 8.0%, the thickness of secondary barriers up to 11.4%, respectively. For an adequate dimensioning of treatment vault shielding barriers it is by no means irrelevant if the accommodated linac operates with or without a flattening filter. The lower consumption of shielding space and material for new treatment vaults housing a FFF machine may reduce building costs, whereas for existing vaults one might benefit in terms of increased weekly workload. Also a more frequent use of monitor unit intense treatment techniques as well as aiming at reduced occupational exposure for staff is conceivable. Copyright © 2013. Published by Elsevier GmbH.
Huang, Yuan-Dong; He, Wen-Rong; Kim, Chang-Nyung
2015-02-01
A two-dimensional numerical model for simulating flow and pollutant dispersion in an urban street canyon is firstly developed using the FLUENT code and then validated against the wind tunnel results. After this, the flow field and pollutant dispersion inside an urban street canyon with aspect ratio W/H = 1 are examined numerically considering five different shapes (vaulted, trapezoidal, slanted, upward wedged, and downward wedged roofs) as well as three different roof height to building height ratios (Z H /H = 1/6, 1/3, and 1/2) for the upstream building roof. The results obtained reveal that the shape and height of an upstream roof have significant influences on flow pattern and pollutant distribution in an urban canyon. A large single clockwise vortex is generated in the canyon for the vaulted upstream roof at Z H /H = 1/6, 1/3, and 1/2, the trapezoidal and downward wedged roofs at Z H /H = 1/6 and 1/3, and the slanted and upward wedged roofs at Z H /H = 1/6, while a main clockwise vortex and a secondary counterclockwise vortex are established for the trapezoidal and downward wedged roofs at Z H /H = 1/2 and the slanted and upward wedged roofs at Z H /H = 1/3 and 1/2. In the one-vortex flow regime, the clockwise vortex moves upward and grows in size with increasing upstream roof height for the vaulted, trapezoidal, and downward wedged roofs. In the two-vortex flow regime, the size and rotational velocity of both upper clockwise and lower counterclockwise vortices increase with the upstream roof height for the slanted and upward wedged roofs. At Z H /H = 1/6, the pollution levels in the canyon are close among all the upstream roof shapes studied. At Z H /H = 1/3, the pollution levels in the canyon for the upward wedged roof and slanted roof are much higher than those for the vaulted, trapezoidal, and downward wedged roofs. At Z H /H = 1/2, the lowest pollution level appears in the canyon for the vaulted upstream roof, while the highest pollution level occurs in the canyon for the upward wedged roof.
NASA Astrophysics Data System (ADS)
Yagoda-Biran, G.; Hatzor, Y. H.
2013-12-01
Evidence for seismically induced damage are preserved in historic masonry structures below the Old City of Jerusalem at a site known locally as the 'Western Wall Tunnels' complex, possibly one of the most important tourist attractions in the world. In the tunnels, structures dated to 500 BC and up until modern times have been uncovered by recent archeological excavation. One of the interesting findings is a 100 m long bridge, composed of two rows of barrel vaults, believed to have been constructed during the 3rd century AD to allow easy access to the Temple Mount. In one of the vaults a single masonry block is displaced 7 cm downward with respect to its neighbors (see figure below). Since the damage seems seismically driven, back analysis of the damage with the numerical Discontinuous Deformation Analysis (DDA) method was performed, in order to constrain the peak ground acceleration (PGA) that had caused the damage. First the numerical method used for back analysis was verified with an analytical solution for the case of a rocking monolithic column, then validated with experimental results for site response analysis. The verification and validation prove the DDA is capable of handling dynamic and wave propagation problems. Next, the back analysis was performed. Results of the dynamic numerical simulations suggest that the damage observed at the vault was induced by seismic vibrations that must have taken place before the bridge was buried underground, namely when it was still in service. We find that the PGA required for causing the observed damage was high - between 1.5 and 2 g. The PGA calculated for Jerusalem on the basis of established attenuation relationships for historic earthquakes that struck the region during the relevant time period is about one order of magnitude lower: 0.14 and 0.48 g, for the events that took place at 362 and 746 AD, respectively. This discrepancy is explained by local site effects that must have amplified bedrock ground motions by a factor of up to 10. This result clearly illustrates the significance of incorporating local site effects when assessing the seismic hazard associated with specific regions in general, and particularly in cities where soft layers separate between the bedrock and the ground surface. The displaced block in Vault 21 in the Western Wall Tunnels.
Maui Optical Tracking and Identification Facility Transition Program.
1981-08-01
USED) 2 OFFICE 19 LASER SUPPORT ROO 35 SERVICE CELL TECHT LIBARY 20 LASLAL 5 ATA LAB 36 UNDERGROUND WATER RESERVOIR S OFFICE 21 LOBBY 37 PUMP VAULT 8...precision at a rate of 50 samples per second on the system digital recorder along with time, housekeeping and ten selected dc channels which are recorded...with 12-bit precision at a rate of 90 samples per second (45 per mirror state). The digitally recorded ac and dc data can be retrieved post-mission and
LOFT. Containment and service building (TAN650). Section through east/west axis ...
LOFT. Containment and service building (TAN-650). Section through east/west axis of building as viewed from the south. Shows basement and grade levels of containment building, connection to control room on west side, air filter vaults, and duct enclosure for air exhaust system. Kaiser engineers 6413-11-STEP/LOFT-650-A-4. Date: October 1964. INEEL index code no. 036-650-00-486-122216 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
The Celestial Vault: The Magic of Astrology
NASA Astrophysics Data System (ADS)
McGaha, J.
2004-11-01
Astrology is a "Geocentric System" that supports the "Astrological Principle". This principle, that human beings and their actions are influenced by the positions of celestial objects, is not objectively supported. The "planetary gods" found in the heavens provided order to help explain the chaotic events in life on earth. Is this why many people think their horoscopes are correct, with the "stars" taking credit? Do "celestial movements" foretell the future? What is the evidence for Astrology? The historical, psychological and physical foundations of astrology will be discussed.
SU-E-T-400: Evaluation of Shielding and Activation at Two Pencil Beam Scanning Proton Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Remmes, N; Mundy, D; Classic, K
2015-06-15
Purpose: To verify acceptably low dose levels around two newly constructed identical pencil beam scanning proton therapy facilities and to evaluate accuracy of pre-construction shielding calculations. Methods: Dose measurements were taken at select points of interest using a WENDI-2 style wide-energy neutron detector. Measurements were compared to pre-construction shielding calculations. Radiation badges with neutron dose measurement capabilities were worn by personnel and also placed at points throughout the facilities. Seven neutron and gamma detectors were permanently installed throughout the facility, continuously logging data. Potential activation hazards have also been investigated. Dose rates near water tanks immediately after prolonged irradiation havemore » been measured. Equipment inside the treatment room and accelerator vault has been surveyed and/or wipe tested. Air filters from air handling units, sticky mats placed outside of the accelerator vault, and water samples from the magnet cooling water loops have also been tested. Results: All radiation badges have been returned with readings below the reporting minimum. Measurements of mats, air filters, cooling water, wipe tests and surveys of equipment that has not been placed in the beam have all come back at background levels. All survey measurements show the analytical shielding calculations to be conservative by at least a factor of 2. No anomalous events have been identified by the building radiation monitoring system. Measurements of dose rates close to scanning water tanks have shown dose rates of approximately 10 mrem/hr with a half-life less than 5 minutes. Measurements around the accelerator show some areas with dose rates slightly higher than 10 mrem/hr. Conclusion: The shielding design is shown to be adequate. Measured dose rates are below those predicted by shielding calculations. Activation hazards are minimal except in certain very well defined areas within the accelerator vault and for objects placed directly in the path of the beam.« less
Raman, Jay D; Lehman, Kathleen K; Dewan, Kalyan; Kirimanjeswara, Girish
2015-09-21
Single institution and population-based studies highlight that infectious complications following transrectal ultrasound guided prostate needle biopsy (TRUS PNB) are increasing. Such infections are largely attributable to quinolone resistant microorganisms which colonize the rectal vault and are translocated into the bloodstream during the biopsy procedure. A povidone iodine rectal preparation (PIRP) at time of biopsy is a simple, reproducible method to reduce rectal microorganism colony counts and therefore resultant infections following TRUS PNB. All patients are administered three days of oral antibiotic therapy prior to biopsy. The PIRP technique involves initially positioning the patient in the standard manner for a TRUS PNB. Following digital rectal examination, 15 ml of a 10% solution of commercially available povidone iodine is mixed with 5 ml of 1% lidocaine jelly to create slurry. A 4 cmx4 cm sterile gauze is soaked in this slurry and then inserted into the rectal vault for 2 min after which it is removed. Thereafter, a disposable cotton gynecologic swab is used to paint both the perianal area and the rectal vault to a distance of 3 cm from the anus. The povidone iodine solution is then allowed to dry for 2-3 min prior to proceeding with standard transrectal ultrasonography and subsequent biopsy. This PIRP technique has been in practice at our institution since March of 2012 with an associated reduction of post-biopsy infections from 4.3% to 0.6% (p=0.02). The principal advantage of this prophylaxis regimen is its simplicity and reproducibility with use of an easily available, inexpensive agent to reduce infections. Furthermore, the technique avoids exposing patients to additional systemic antibiotics with potential further propagation of multi-drug resistant organisms. Usage of PIRP at TRUS PNB, however, is not applicable for patients with iodine or shellfish allergies.
Functional Compromise in the Middle Vault in the Management of Revision Rhinoplasty.
Wang, Leo; Friedman, Oren
2018-06-01
As rhinoplasty procedures become more common, the need for revision surgeries increases as well. Unlike primary rhinoplasties, revision rhinoplasties can be more challenging because of anatomic differences from initial surgery, a lack of available cartilage, tissue remodeling responses, and other complications. As such, surgeons should be prepared to address revision rhinoplasty patients differently from primary rhinoplasty patients. Here, the authors describe a generalizable approach to revision functional rhinoplasty patients and detail some of the surgical techniques that can be employed to achieve optimal outcomes, with particular attention paid to procedures that can be used in the middle vault. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Otogenic pneumocephalus as a complication of multiple myeloma.
Maguire, Melissa J; Nath, Uma; Bignardi, Guiseppe E
2012-09-01
We report a case of otogenic pneumocephalus in an 80-year-old woman with multiple myeloma. The pneumocephalus was associated with Haemophilus influenzae otitis media and reactive meningitis in the absence of an intracranial brain abscess. Myeloma causes thinning of bone trabeculae and destructive lytic bone lesions. This can predispose to a risk of pathologic fractures and, in patients with skull vault involvement, to the rare complication of pneumocephalus. Therefore, pneumocephalus should be considered in the differential diagnosis of acute headache in patients with multiple myeloma, especially those with skull vault involvement. Prompt computed tomography and liaison between the otolaryngology and neurology teams may assist in making an early diagnosis and preventing life-threatening intracranial complications.
RxPATROL: a Web-based tool for combating pharmacy theft.
Smith, Meredith Y; Graham, J Aaron; Haddox, J David; Steffey, Amy
2009-01-01
To report the incidence of pharmacy-related burglaries and robberies and characteristics of pharmacies where such crimes have occurred using recent data from Rx Pattern Analysis Tracking Robberies & Other Losses (RxPATROL), a national Web-based information clearinghouse on pharmacy-related theft of prescription medications and over-the-counter products. Descriptive, nonexperimental study. United States between 2005 and 2006. Not applicable. Not applicable. Number of pharmacy theft reports received; incident type, date, and location; point of entry; and pharmacy security features. Between 2005 and 2006, 202 pharmacy burglary and 299 pharmacy robbery reports from 45 different states were filed with RxPATROL. More than 70% of pharmacies reporting such crimes lacked a security camera. Among those reporting a burglary, 60% lacked dead bolt locks, a solid exterior door, a motion detector device, or a safe or vault for storage of controlled substances. Burglars most often obtained access to the pharmacy via the front door. RxPATROL is a Web-based tool that can assist pharmacies and law enforcement in collaborating more effectively to combat and prevent pharmacy-related crimes.
Fernández-Navajas, Ángel; Merello, Paloma; Beltrán, Pedro; García-Diego, Fernando-Juan
2013-01-01
Cultural Heritage preventive conservation requires the monitoring of the parameters involved in the process of deterioration of artworks. Thus, both long-term monitoring of the environmental parameters as well as further analysis of the recorded data are necessary. The long-term monitoring at frequencies higher than 1 data point/day generates large volumes of data that are difficult to store, manage and analyze. This paper presents software which uses a free open source database engine that allows managing and interacting with huge amounts of data from environmental monitoring of cultural heritage sites. It is of simple operation and offers multiple capabilities, such as detection of anomalous data, inquiries, graph plotting and mean trajectories. It is also possible to export the data to a spreadsheet for analyses with more advanced statistical methods (principal component analysis, ANOVA, linear regression, etc.). This paper also deals with a practical application developed for the Renaissance frescoes of the Cathedral of Valencia. The results suggest infiltration of rainwater in the vault and weekly relative humidity changes related with the religious service schedules. PMID:23447005
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oberson, Greg; Dunn, Darrell; Mintz, Todd
2013-07-01
At a number of locations in the U.S., spent nuclear fuel (SNF) is maintained at independent spent fuel storage installations (ISFSIs). These ISFSIs, which include operating and decommissioned reactor sites, Department of Energy facilities in Idaho, and others, are licensed by the U.S. Nuclear Regulatory Commission (NRC) under Title 10 of the Code of Federal Regulations, Part 72. The SNF is stored in dry cask storage systems, which most commonly consist of a welded austenitic stainless steel canister within a larger concrete vault or overpack vented to the external atmosphere to allow airflow for cooling. Some ISFSIs are located inmore » marine environments where there may be high concentrations of airborne chloride salts. If salts were to deposit on the canisters via the external vents, a chloride-rich brine could form by deliquescence. Austenitic stainless steels are susceptible to chloride-induced stress corrosion cracking (SCC), particularly in the presence of residual tensile stresses from welding or other fabrication processes. SCC could allow helium to leak out of a canister if the wall is breached or otherwise compromise its structural integrity. There is currently limited understanding of the conditions that will affect the SCC susceptibility of austenitic stainless steel exposed to marine salts. NRC previously conducted a scoping study of this phenomenon, reported in NUREG/CR-7030 in 2010. Given apparent conservatisms and limitations in this study, NRC has sponsored a follow-on research program to more systematically investigate various factors that may affect SCC including temperature, humidity, salt concentration, and stress level. The activities within this research program include: (1) measurement of relative humidity (RH) for deliquescence of sea salt, (2) SCC testing within the range of natural absolute humidity, (3) SCC testing at elevated temperatures, (4) SCC testing at high humidity conditions, and (5) SCC testing with various applied stresses. Results to date indicate that the deliquescence RH for sea salt is close to that of MgCl{sub 2} pure salt. SCC is observed between 35 and 80 deg. C when the ambient (RH) is close to or higher than this level, even for a low surface salt concentration. (authors)« less
Gorgolewski, Krzysztof J; Varoquaux, Gael; Rivera, Gabriel; Schwartz, Yannick; Sochat, Vanessa V; Ghosh, Satrajit S; Maumet, Camille; Nichols, Thomas E; Poline, Jean-Baptiste; Yarkoni, Tal; Margulies, Daniel S; Poldrack, Russell A
2016-01-01
NeuroVault.org is dedicated to storing outputs of analyses in the form of statistical maps, parcellations and atlases, a unique strategy that contrasts with most neuroimaging repositories that store raw acquisition data or stereotaxic coordinates. Such maps are indispensable for performing meta-analyses, validating novel methodology, and deciding on precise outlines for regions of interest (ROIs). NeuroVault is open to maps derived from both healthy and clinical populations, as well as from various imaging modalities (sMRI, fMRI, EEG, MEG, PET, etc.). The repository uses modern web technologies such as interactive web-based visualization, cognitive decoding, and comparison with other maps to provide researchers with efficient, intuitive tools to improve the understanding of their results. Each dataset and map is assigned a permanent Universal Resource Locator (URL), and all of the data is accessible through a REST Application Programming Interface (API). Additionally, the repository supports the NIDM-Results standard and has the ability to parse outputs from popular FSL and SPM software packages to automatically extract relevant metadata. This ease of use, modern web-integration, and pioneering functionality holds promise to improve the workflow for making inferences about and sharing whole-brain statistical maps. Copyright © 2015 Elsevier Inc. All rights reserved.
Moon, Il Yung; Oh, Kap Sung
2014-01-01
Background Infants with deformational plagiocephaly (DP) usually present with cranial vault deformities as well as facial asymmetry. The purpose of this study was to use three-dimensional anthropometric data to evaluate the influence of cranial deformities on facial asymmetry. Methods We analyzed three-dimensional computed tomography data for infants with DP (n=48) and without DP (n=30, control). Using 16 landmarks and 3 reference planes, 22 distance parameters and 2 angular parameters were compared. This cephalometric assessment focused on asymmetry of the orbits, nose, ears, maxilla, and mandible. We then assessed the correlation between 23 of the measurements and cranial vault asymmetry (CVA) for statistical significance using relative differences and correlation analysis. Results With the exception of few orbital asymmetry variables, most measurements indicated that the facial asymmetry was greater in infants with DP. Mandibular and nasal asymmetry was correlated highly with severity of CVA. Shortening of the ipsilateral mandibular body was particularly significant. There was no significant deformity in the maxilla or ear. Conclusion This study demonstrated that the cranial vault deformity in DP is associated with facial asymmetry. Compared with the control group, the infants with DP were found to have prominent asymmetry of the nose and mandible. PMID:28913202
Balmer, Nigel; Pleasence, Pascoe; Nevill, Alan
2012-01-01
A number of studies have pointed to a plateauing of athletic performance, with the suggestion that further improvements will need to be driven by revolutions in technology or technique. In the present study, we examine post-war men's Olympic performance in jumping events (pole vault, long jump, high jump, triple jump) to determine whether performance has indeed plateaued and to present techniques, derived from models of human growth, for assessing the impact of technological and technical innovation over time (logistic and double logistic models of growth). Significantly, two of the events involve well-documented changes in technology (pole material in pole vault) or technique (the Fosbury Flop in high jump), while the other two do not. We find that in all four cases, performance appears to have plateaued and that no further "general" improvement should be expected. In the case of high jump, the double logistic model provides a convenient method for modelling and quantifying a performance intervention (in this case the Fosbury Flop). However, some shortcomings are revealed for pole vault, where evolutionary post-war improvements and innovation (fibre glass poles) were concurrent, preventing their separate identification in the model. In all four events, it is argued that further general growth in performance will indeed need to rely predominantly on technological or technical innovation.
NASA Technical Reports Server (NTRS)
Murthy, G.; Yost, W. T.; Ballard, R. E.; Watenpaugh, D. E.; Kawai, Y.; Hargens, A. R.
1994-01-01
Headaches are commonly experienced by astronauts in microgravity and by subjects undergoing head-down tilt (simulated microgravity on Earth). Exposure to microgravity probably elevates blood pressure and flow in the head which may increase intracranial volume (ICV) and pressure (ICP) and in turn cause headache. Due to the slightly compliant nature of the cranial vault and the encasement of brain and its vasculature within this vault, any increase of ICV will increase ICP and slightly distend the cranium. Previous studies document perivascular edema and increased ICP in rhesus monkeys during head-down tilt. Elevated ICP has also been reported in humans during head-down tilt. ICP measurements in healthy humans are rare because of the invasiveness of currently-available measurement techniques. Therefore, we proposed a noninvasive ultrasound technique to assess changes of ICV and JCP. The ultrasound principle is based on compliance of the cranial vault. A 450 kHz ultrasound stimulus is transmitted through the cranium by a transducer every 7.5-10 msec. The ultrasound wave enters the brain tissue, reflects off the opposite side of the cranium and is received by the same transducer. The detected wave is compared for phase quadrature (90 deg.to transmitted wave). Because the electronic circuitry of the device maintains a 90 deg. phase (phi), any alterations in the detected wave caused by an increase of ICV and ICP will be reflected as a change in the wave frequency. Phase shift is directly proportional to path length of the wave, DELTA x, which is expressed as DELTA x = phi lambda/2 pi where lambda is wavelength. Elevated ICV and ICP expand the cranial vault and increase path length of the wave (a measure of intracranial distance). Increased path length equals reduced frequency of the detected wave. Reduced frequency is then related to elevated ICP. This technique has potential uses for ICP studies of astronauts in space and head trauma patients on Earth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lloret, Marta; Instituto Canario de Investigacion del Cancer, Canary Islands; Lara, Pedro Carlos
Purpose: We investigated the relationship between major vault protein (MVP) expression, the nonhomologous end-joining (NHEJ) repair gene Ku70/80, and related genes involved in the regulation of apoptosis and proliferation to shed light on the possible causes of genetic instability, tumor progression, and resistance to oncologic treatment in patients with clinical cervical cancer. Methods and Materials: One hundred sixteen consecutive patients with localized cervix carcinoma were prospectively included in this study from July 1997 to Dec 2003. Patients were staged according to the tumor, node, metastasis (TNM) classification. Forty patients had Stage I disease, 45 had Stage II, and 31 hadmore » Stage III/IVA. Most patients had squamous tumors (98 cases) and Grades II (52 cases) and III (45 cases) carcinomas. Expression of MVP, Ku70/80, Insulin-Like Growth Factor-1 receptor (IGF-1R), BCL2-associated X protein (BAX), B-cell CLL/lymphoma 2 (BCL-2), p53, and Ki67 was studied by using immunohistochemistry in paraffin-embedded tumor tissue. Results: Tumors overexpressing MVP (65 of 116 cases) showed low levels of Ku70/80 (p = 0.013) and BAX expression (p < 0.0001). Furthermore, low Ku70/80 expression was strongly related to suppressed BAX (p < 0.001) and, to a lesser extent, upregulated BCL-2 (p = 0.042), altered p53 (p = 0.038), and increased proliferation (p = 0.002). Conclusion: We hypothesize that an early regulatory mechanism favors homologous or NHEJ repair at first, mediated by vaults along with other factors yet to be elucidated. If vaults are overexpressed, NHEJ repair may be suppressed by means of several mechanisms, with resultant genomic instability. These mechanisms may be associated with the decision of damaged cells to survive and proliferate, favoring tumor progression and reducing tumor response to oncologic treatment through the development of resistant cell phenotypes. Additional clinical studies are necessary to test this hypothesis.« less
SU-E-T-168: Characterization of Neutrons From the TrueBeam Treatment Head
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sawkey, D; Svatos, M
2015-06-15
Purpose: Calculate neutron production and transport in the TrueBeam treatment head, as input for vault design and phantom dose calculations. Methods: A detailed model of the treatment head, including shielding components off the beam axis, was created from manufacturer’s engineering drawings. Simulations were done with Geant4 for the 18X, 15X, 10X and 10FFF beams, tuned to match measured dose distributions inside the treatment field. Particles were recorded on a 70 cm radius sphere surrounding the treatment head enabling input into simulations of vaults. Results: For the 18X beam, 11×10{sup 9} neutrons/MU were observed. The energy spectrum was a broad peakmore » with average energy 0.37 MeV. With jaws closed, 48% of the neutrons were generated in the primary collimator, 18% in the jaws, 12% in the target, and 10% in the flattening filter. With wide open jaws, few neutrons were produced in the jaws and consequently total neutron production dropped to 8.5×10{sup 9} neutrons/MU. Angular distributions were greatest along the beam axis (12×10{sup 9} neutrons/MU/sr, within 2 deg of the beam axis) and antiparallel to the beam axis (7×10{sup 9} neutrons/MU/sr). Peaks were observed in the neutron energy spectrum, corresponding to elastic scattering resonances in the shielding materials. Neutron production was lower for the other beams studied: 4.1×10{sup 9} neutrons/MU for 15X, 0.38×10{sup 9} neutrons/MU for 10X, and 0.22×10{sup 9} neutrons/MU for 10FFF. Despite dissimilar treatment head geometries and materials, the neutron production and energy spectrum were similar to those reported for Clinac accelerators. Conclusion: Detailed neutron production and leakage calculations for the TrueBeam treatment head were done. Unlike other studies, results are independent of the surrounding vault, enabling vault design calculations.« less
Using modern human cortical bone distribution to test the systemic robusticity hypothesis.
Baab, Karen L; Copes, Lynn E; Ward, Devin L; Wells, Nora; Grine, Frederick E
2018-06-01
The systemic robusticity hypothesis links the thickness of cortical bone in both the cranium and limb bones. This hypothesis posits that thick cortical bone is in part a systemic response to circulating hormones, such as growth hormone and thyroid hormone, possibly related to physical activity or cold climates. Although this hypothesis has gained popular traction, only rarely has robusticity of the cranium and postcranial skeleton been considered jointly. We acquired computed tomographic scans from associated crania, femora and humeri from single individuals representing 11 populations in Africa and North America (n = 228). Cortical thickness in the parietal, frontal and occipital bones and cortical bone area in limb bone diaphyses were analyzed using correlation, multiple regression and general linear models to test the hypothesis. Absolute thickness values from the crania were not correlated with cortical bone area of the femur or humerus, which is at odds with the systemic robusticity hypothesis. However, measures of cortical bone scaled by total vault thickness and limb cross-sectional area were positively correlated between the cranium and postcranium. When accounting for a range of potential confounding variables, including sex, age and body mass, variation in relative postcranial cortical bone area explained ∼20% of variation in the proportion of cortical cranial bone thickness. While these findings provide limited support for the systemic robusticity hypothesis, cranial cortical thickness did not track climate or physical activity across populations. Thus, some of the variation in cranial cortical bone thickness in modern humans is attributable to systemic effects, but the driving force behind this effect remains obscure. Moreover, neither absolute nor proportional measures of cranial cortical bone thickness are positively correlated with total cranial bone thickness, complicating the extrapolation of these findings to extinct species where only cranial vault thickness has been measured. Copyright © 2018 Elsevier Ltd. All rights reserved.
Anatomy and Surgical Approaches to the Rabbit Nasal Septum.
Badran, Karam W; Chang, John C; Kuan, Edward C; Wong, Brian J F
2017-09-01
The rabbit is the primary animal model used to investigate aspects of nasal surgery. Although several studies have used this model, none has provided a comprehensive analysis of the surgical anatomy and techniques used to gain access to the rabbit nasal fossae and septum. To describe and optimize the surgical anatomy and approach to the rabbit nasal vault and septal cartilage. In an ex vivo animal study conducted at an academic medical center, preliminary cadaveric dissections were performed on rabbit head specimens to establish familiarity with relevant anatomy and rehearse various approaches. Live Pasteurella-free New Zealand white rabbits (3.5-4.0 kg) were used to further develop this surgical technique developed here. Access of the nasal vault was gained through a midline nasal dorsum incision and creation of an osteoplastic flap with a drill. Submucosal resection was performed with preservation of the mucoperichondrium. All rabbits were monitored daily for 4 weeks in the postoperative period for signs of infection, pain, and complications. The study was conducted from June 1, 2014, to December 1, 2014. Surgical anatomy and techniques used to gain access to the rabbit nasal vault and harvest septal cartilage. Four Pasteurella-free New Zealand white rabbits (Western Organ Rabbit Co), ranging in age from 9 to 12 months and weighing between 3.5 and 4.0 kg, were used in this study. Initial dissections demonstrated the feasibility of harvesting septal cartilage while preserving the mucoperichondrial envelope. Access to the nasal vault through this 3-osteotomy approach allowed for maximal exposure to the nasal cavity bilaterally while maintaining the integrity of the mucoperichondrium following septal cartilage harvest. The maximum amount of bulk, en bloc, cartilage harvested was 1.0 × 2.5 cm. Following surgical dissection, all animals maintained adequate airway patency and support to midface structures. Furthermore, all specimens preserved the integrity of the mucoperichondrium, septum, vascular anatomy, and airway dynamics. No operative complications, postoperative airway compromise, or infections were observed. Access to the rabbit nasal vault and septal cartilage is feasible through a variety of surgical approaches and techniques. To date, this is the first study to meticulously document and review the surgical approaches to the rabbit nasal cavity. This approach describes a novel, 3-osteotomy method of accessing the nasal cavity bilaterally and successfully harvesting rabbit septal cartilage in a submucoperichondrial plane. The ability to preserve native anatomy and function allows for improved outcomes in translational and animal guided clinical research. NA.
Early postnatal cranial vault reduction and fixation surgery for severe hydrocephalic macrocephaly.
Iyer, Rajiv R; Carey, Carolyn M; Rottgers, S Alex; Tetreault, Lisa; Shimony, Nir; Katzenstein, Jennifer; Ruas, Ernesto; Tuite, Gerald F
2018-05-01
OBJECTIVE Infants with severe hydrocephalus and extreme macrocephaly typically undergo CSF diversion early in life, which can result in significant cranial deformity due to CSF overdrainage. In this scenario, overlap of the cranial plates can precede the development of secondary synostosis and/or severe, permanent cranial deformity. As a result, extensive cranial vault remodeling is sometimes undertaken later in life, which is often challenging and has been associated with mortality and a high morbidity rate. The authors have previously described a technique for early postnatal cranial vault reduction and fixation (CVRF), in which the calvarial bones are stabilized using absorbable fixation plates in the neonatal period, in an attempt to facilitate patient positioning, simplify hydrocephalus management, and improve cosmesis. Here, the authors describe their institutional experience managing patients with extreme neonatal hydrocephalus with CSF diversion, with and without CVRF, over the past 12 years. METHODS The authors retrospectively reviewed the charts of infants with extreme hydrocephalus (head circumference > 49 cm) treated at their children's hospital with ventriculoperitoneal shunting, with or without CVRF, between 2005 and 2017. Data collected included age, sex, etiology of hydrocephalus, type of CVRF performed (anterior, posterior, or combined), follow-up duration, orbitofrontal circumference, craniometric measurements, intraoperative blood loss, operative duration, and postoperative complications. Developmental data were collected using the third edition of the Ages and Stages Questionnaire. Photographic imaging was used to demonstrate esthetic outcomes, and family questionnaires were used to evaluate satisfaction with the esthetic outcome. RESULTS Eleven patients with extreme neonatal hydrocephalus underwent CSF shunting; 5 underwent shunting alone and 6 patients underwent shunting and CVRF. For patients who underwent shunting and CVRF, the median age at CVRF was 6 days and the median interval between shunt placement and CVRF was 2.5 days. The mean extent of calvarial vault volume reduction was 44.5% (± 3.9%). The mean duration of the CVRF procedure was 108 minutes, and 5 of 6 patients required intraoperative transfusion. Of the 5 patients who underwent shunting alone, 3 developed severe cranial deformities. Of 6 patients who underwent shunting and CVRF, 1 had a poor cosmetic outcome. In the shunting-alone group, 2 patients died and 1 required extensive cranial vault correction at 10 years of age. One patient in the shunting and CVRF group also died. CONCLUSIONS CVRF in combination with CSF shunting in the neonatal period can simplify the treatment of the rare case of severe hydrocephalic macrocephaly and leads to cosmetic outcomes that are considered good by their families.
Proton Therapy Dose Characterization and Verification
2013-10-01
predefined acceptance criteria. The Calypso System accurately localizes LT and LO patients in the IBA proton therapy vault at the University of Pennsylvania...earlier vet>ions of mdioct.’omio 0 lm. Thcrr ’" Jechnkul 1\\Sues ~nd challenge~ tluu mu.~t be ad~ts:led and rrsolvtd pnor lo Ibm nppllculion for do...IOcmatthch«enter) from a Varian l100linc1!r aecdcmtur (llnac) dirr<ltd plll’nllel lo nn EBTI film ~nd wtchtd bCiwttn slit!• of ••.lhd wurcr1 M. The plwuom
Development of Vault Toilet Waste Treatment Systems.
1978-06-01
wi nd turbine used was a Savoniut’ Wing Rotor, a vertical axis rotor developed by S. J. Savonius in the early 1920’s and used exten- sively in the...2 ) i t was a vertical axis turbine which minimi zed tower con- struction costs, and (3) its high starting torque made it wel l suited to ariving an...ihe turbine constructed by this investigation consistea of two rotors, each 4 ft (1.2 m) high and 7 ft (2.1 m) in wi ath across the long axis , mounted
Effective way to reconstruct arch bridges using concrete walls and transverse strands
NASA Astrophysics Data System (ADS)
Klusáček, Ladislav; Pěkník, Robin; Nečas, Radim
2017-09-01
There are more than 500 masonry arch bridges in the Czech Road system and about 2500 in the Czech Railway system. Many of them are cracked in the longitudinal (span) direction. The barrel vaults are separated by the cracks into partial masonry arches without load bearing connection in transverse direction. These constructions are about 150 years old and they are also too narrow for the current road system. This paper presents a strengthening method for masonry arch bridges using transverse post-tensioning. This method is very useful not only for strengthening in the transverse direction, but widening of masonry arches can be taken as secondary effect especially in case of road bridges. Several bridges were successfully repaired with the use of this system which seems to be effective and reliable.
Plata Bello, Julio; Garcia-Marin, Victor
2013-10-18
POEMS syndrome (an acronym of polyneuropathy, organomegaly, endocrinopathy, multiple myeloma and skin changes) is a paraneoplastic disorder related to an underlying plasma cell dyscrasia. The development of such a syndrome is rare and its association with calvarial plasmocytoma is even less common, with only two previous reported cases. We describe, in detail, an unusual presentation of cranial plasmocytoma associated with POEMS syndrome and briefly discuss the possible role of surgery in the management of this disease. We present the case of a 45-year-old Caucasian man who was admitted to our department presenting with progressive weakness in his lower limbs, enlarged lymph nodes and a large mass on the scalp with intense bone erosion. POEMS criteria were present and pathological studies confirmed a Castleman's variant plasmocytoma. Clinical status improved noticeably after the excision of the plasmocytoma and the treatment was completed with radiotherapy and steroid pulse therapy. Cranial vault plasmocytoma and its association with POEMS syndrome are rare conditions with few previously reported cases. Although the role of surgery is not clearly defined in POEMS syndrome guidelines, the fact that there seems to be a better prognosis and clinical outcome when surgery is used as a part of the management in POEMS syndrome with cranial vault plasmocytoma is worth discussing.
Ontogenetic changes in cranial vault thickness in a modern sample of Homo sapiens.
Anzelmo, Marisol; Ventrice, Fernando; Barbeito-Andrés, Jimena; Pucciarelli, Héctor M; Sardi, Marina L
2015-01-01
This work assesses cranial vault thickness (CVT) ontogenetic changes using a computed tomography database to register thickness across multiple regions. Vault images of 143 individuals from 0 to 31 years old were analyzed by thickness semiautomatic measurements. For each individual, we obtained a thickness mean measure (TMM) and its coefficient of variation, a measure of endocranial volume (EV), the distribution of relative frequencies of thickness-relative frequency polygon, and a topographic mapping that shows the thickness arrangement through a chromatic scale. Ontogenetic changes of these variables were evaluated by different regression models (TMM vs. age, EV vs. age, TMM vs. EV) and visual comparisons between the age groups. TMM increased during ontogeny until the onset of adulthood without sex differences, but the most accelerated growth rates occur during the first 6 years of postnatal life. TMM variations were associated with EV only in infants and children, but not in later periods. The polygons showed a flattening during ontogeny, probably due to an increase in thickness variation within individuals. However, the adult pattern of thickness arrangement, with the lateral region thinner than the regions near sagittal plane, was detected from infancy. The pattern of thickness arrangement is established early in ontogeny but CVT increases and changes in distribution until adolescence. Several factors may influence CVT, such as the brain, muscles, vessels, and sutures. © 2014 Wiley Periodicals, Inc.
Dental arch dimensional changes after adenotonsillectomy in prepubertal children.
Petraccone Caixeta, Anna Cristina; Andrade, Ildeu; Bahia Junqueira Pereira, Tatiana; Franco, Letícia Paiva; Becker, Helena Maria Gonçalves; Souki, Bernardo Quiroga
2014-04-01
The purposes of this study were to investigate the dental arch changes after adenotonsillectomies in prepubertal children and to compare the dental arch dimensions of mouth-breathing and nasal-breathing children. The sample included 49 prepubertal severely obstructed mouth-breathing children and 46 prepubertal nasal-breathing children. Twenty-four of the 49 mouth-breathing children had an adenotonsillectomy and composed the adenotonsillectomy subgroup. The 25 children in whom the mouth-breathing pattern was unchanged during the 1-year study period composed the control subgroup. The mouth-breathing children showed a deeper palatal vault, a larger mandibular width, and a larger mandibular arch length in comparison with the nasal-breathing children. After airway clearance, the adenotonsillectomy group showed a significant maxillary transverse width gain compared with the control subgroup. The control subgroup showed a significant deepening of the palatal height when compared with the adenotonsillectomy subgroup after 1 year. The adenotonsillectomy subgroup had a significantly different pattern of arch development compared with the untreated controls. After adenotonsillectomy, the mouth-breathing children showed greater maxillary transverse development than did the controls. The palatal vault deepened in the untreated children. The mouth-breathing children showed a deeper palatal vault, a larger mandibular width, and a larger mandibular arch length in comparison with the nasal-breathing children. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... pads beneath electrical equipment, curbing, exterior structural building components, indoor vaults, and... after the hexane is exposed to air. EPA strongly recommends that the gauze (or glass wool) be prepared...
Gray, Rachel; Gougoutas, Alexander; Nguyen, Vinh; Taylor, Jesse; Bastidas, Nicholas
2017-06-01
Virtual Surgical Planning (VSP) and computer-aided design/computer-aided manufacturing (CAD/CAM) have recently helped improve efficiency and accuracy in many different craniofacial surgeries. Research has mainly focused on the use in the adult population with the exception of the use for mandibular distractions and cranial vault remodeling in the pediatric population. This study aims to elucidate the role of VSP and CAD/CAM in complex pediatric craniofacial cases by exploring its use in the correction of midface hypoplasia, orbital dystopia, mandibular reconstruction, and posterior cranial vault expansion. A retrospective analysis of thirteen patients who underwent 3d, CAD/CAM- assisted preoperative surgical planning between 2012 and 2016 was performed. All CAD/CAM assisted surgical planning was done in conjunction with a third party vendor (either 3D Systems or Materialise). Cutting and positioning guides as well as models were produced based on the virtual plan. Surgeries included free fibula mandible reconstruction (n = 4), lefort I osteotomy and distraction (n = 2), lefort II osteotomy with monobloc distraction (n = 1), expansion of the posterior vault for correction of chiari malformation (n = 3), and secondary orbital and midface reconstruction for facial trauma (n = 3). The patient's age, diagnosis, previous surgeries, length of operating time, complications, and post-surgery satisfaction were determined. In all cases we found presurgical planning was helpful to improve accuracy and significantly decrease intra-operative time. In cases where distraction was used, the planned and actual vectors were found to be accurate with excellent clinical outcomes. There were no complications except for one patient who experienced a wound infection post-operatively which did not alter the ultimate reconstruction. All patients experienced high satisfaction with their outcomes and excellent subjective aesthetic results were achieved. Preoperative planning using CAD/CAM and VSP allows for safe and precise craniofacial reconstruction in complex pediatric cases with a reduction of operative time. Copyright © 2017 Elsevier B.V. All rights reserved.
Collaborative drug discovery for More Medicines for Tuberculosis (MM4TB)
Ekins, Sean; Spektor, Anna Coulon; Clark, Alex M.; Dole, Krishna; Bunin, Barry A.
2016-01-01
Neglected disease drug discovery is generally poorly funded compared with major diseases and hence there is an increasing focus on collaboration and precompetitive efforts such as public–private partnerships (PPPs). The More Medicines for Tuberculosis (MM4TB) project is one such collaboration funded by the EU with the goal of discovering new drugs for tuberculosis. Collaborative Drug Discovery has provided a commercial web-based platform called CDD Vault which is a hosted collaborative solution for securely sharing diverse chemistry and biology data. Using CDD Vault alongside other commercial and free cheminformatics tools has enabled support of this and other large collaborative projects, aiding drug discovery efforts and fostering collaboration. We will describe CDD's efforts in assisting with the MM4TB project. PMID:27884746
MEASUREMENT OF WASTE LOADING IN SALTSTONE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harbour, J; Vickie Williams, V
2008-07-18
One of the goals of the Saltstone variability study is to identify the operational and compositional variables that control or influence the important processing and performance properties of Saltstone grout mixtures. One of those properties of importance is the Waste Loading (WL) of the decontaminated salt solution (DSS) in the Saltstone waste form. Waste loading is a measure of the amount of waste that can be incorporated within a waste form. The value of the Saltstone waste loading ultimately determines the number of vaults that will be required to disposition all of the DSS. In this report, the waste loadingmore » is defined as the volume in milliliters of DSS per liter of Saltstone waste form. The two most important parameters that determine waste loading for Saltstone are water to cementitious material (w/cm) ratio and the cured grout density. Data are provided that show the dependence of waste loading on the w/cm ratio for a fixed DSS composition using the current premix material (45% Blast Furnace Slag (BFS), 45% Fly Ash (FA) and 10% Ordinary Portland Cement (OPC)). The impact of cured grout density on waste loading was also demonstrated. Mixes (at 0.60 w/cm) made with a Modular Caustic side extraction Unit (MCU) simulant and either OPC or BFS have higher cured grout densities than mixes made with premix and increase the WL to 709 mL/L for the OPC mix and 689 mL/L for the BFS mix versus the value of 653 mL/L for MCU in premix at 0.60 w/cm ratio. Bleed liquid reduces the waste loading and lowers the effective w/cm ratio of Saltstone. A method is presented (and will be used in future tasks) for correcting the waste loading and the w/cm ratio of the as-batched mixes in those cases where bleed liquid is present. For example, the Deliquification, Dissolution and Adjustment (DDA) mix at an as-batched 0.60 w/cm ratio, when corrected for % bleed, gives a mix with a 0.55 w/cm ratio and a WL that has been reduced from 662 to 625 mL/L. An example is provided that demonstrated the quantitative impact of WL on the number of cells (each Saltstone vault contains two cells) required to disposition all of the {approx}100 million gallons of DSS available in the tanks. This calculation revealed that the number of cells required over the range of 0.48 to 0.62 w/cm ratio (equivalent to a WL range of 591 to 666 mL/L) varies from 65 to 57 cells (33 to 29 vaults). The intent of this oversimplified example was to show the range of variation in vaults expected due to w/cm ratio rather than to estimate the actual number of vaults required. There is a tradeoff between the waste loading and the processing and performance properties of Saltstone. The performance properties improve in general as the w/cm ratio decreases whereas the waste loading is reduced at lower w/cm ratios resulting in a larger number of Saltstone vaults. The final performance and processing requirements of Saltstone will determine the maximum waste loading achievable.« less
Méndez-Villafañe, R; Guerrero, J E; Embid, M; Fernández, R; Grandio, R; Pérez-Cejuela, P; Márquez, J L; Alvarez, F; Ortego, P
2014-10-01
The construction of the new Neutron Standards Laboratory at CIEMAT (Laboratorio de Patrones Neutrónicos) has been finalised and is ready to provide service. The facility is an ∼8 m×8 m×8 m irradiation vault, following the International Organization for Standardization 8529 recommendations. It relies on several neutron sources: a 5-GBq (5.8× 10(8) s(-1)) (252)Cf source and two (241)Am-Be neutron sources (185 and 11.1 GBq). The irradiation point is located 4 m over the ground level and in the geometrical centre of the room. Each neutron source can be moved remotely from its storage position inside a water pool to the irradiation point. Prior to this, an important task to design the neutron shielding and to choose the most appropriate materials has been developed by the Radiological Security Unit and the Ionizing Radiations Metrology Laboratory. MCNPX was chosen to simulate the irradiation facility. With this information the walls were built with a thickness of 125 cm. Special attention was put on the weak points (main door, air conditioning system, etc.) so that the ambient dose outside the facility was below the regulatory limits. Finally, the Radiation Protection Unit carried out a set of measurements in specific points around the installation with an LB6411 neutron monitor and a Reuter-Stokes high-pressure ion chamber to verify experimentally the results of the simulation. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Design and Implementation of the National Seismic Monitoring Network in the Kingdom of Bhutan
NASA Astrophysics Data System (ADS)
Ohmi, S.; Inoue, H.; Chophel, J.; Pelgay, P.; Drukpa, D.
2017-12-01
Bhutan-Himalayan district is located along the plate collision zone between Indian and Eurasian plates, which is one of the most seismically active region in the world. Recent earthquakes such as M7.8 Gorkha Nepal earthquake in April 25, 2015 and M6.7 Imphal, India earthquake in January 3, 2016 are examples of felt earthquakes in Bhutan. However, there is no permanent seismic monitoring system ever established in Bhutan, whose territory is in the center of the Bhutan-Himalayan region. We started establishing permanent seismic monitoring network of minimum requirements and intensity meter network over the nation. The former is composed of six (6) observation stations in Bhutan with short period weak motion and strong motion seismometers as well as three (3) broad-band seismometers, and the latter is composed of twenty intensity meters located in every provincial government office. Obtained data are transmitted to the central processing system in the DGM office in Thimphu in real time. In this project, DGM will construct seismic vault with their own budget which is approved as the World Bank project, and Japan team assists the DGM for site survey of observation site, designing the observation vault, and designing the data telemetry system as well as providing instruments for the observation such as seismometers and digitizers. We already started the operation of the six (6) weak motion stations as well as twenty (20) intensity meter stations. Additionally, the RIMES (Regional Integrated Multi-hazard Early Warning System for Africa and Asia) is also providing eight (8) weak motion stations and we are keeping close communication to operate them as one single seismic monitoring network composed of fourteen (14) stations. This network will be definitely utilized for not only for seismic disaster mitigation of the country but also for studying the seismotectonics in the Bhutan-Himalayan region which is not yet precisely revealed due to the lack of observation data in the past.
Testing various modes of installation for permanent broadband stations in open field environment
NASA Astrophysics Data System (ADS)
Vergne, Jérôme; Charade, Olivier; Arnold, Benoît; Louis-Xavier, Thierry
2014-05-01
In the framework of the RESIF (Réseau Sismologique et géodésique Français) project, we plan to install more than one hundred new permanent broadband stations in metropolitan France within the next 6 years. Whenever possible, the sensors will be installed in natural or artificial underground cavities that provide a stable thermal environment. However such places do not exist everywhere and we expect that about half the future stations will have to be set up in open fields. For such sites, we are thus looking for a standard model of hosting infrastructure for the sensors that would be easily replicated and would provide good noise level performances at long periods. Since early 2013, we have been operating a prototype station at Clévilliers, a small location in the sedimentary Beauce plain, where we test three kinds of buried seismic vaults and a down-hole installation. The cylindrical seismic vaults are 3m deep and 1m wide and only differ by the type of coupling between the casing and the concrete slab where we installed insulated Trillium T120PA seismometers. The down-hole installation consists in a 3m deep well hosting a Trillium Posthole seismometer. For reference, another sensor has been installed in a ~50cm deep hole, similarly to the way we test every new potential site. Here we compare the noise level in each infrastructure at different frequencies. We observe quite similar performances for the vertical component recorded in the different wells. Conversely, the noise levels on the horizontal components at periods greater than 10s vary by more than 20dB depending on the installation condition. The best results are obtained in the completely decoupled vault and for the down-hole setting, both showing performances comparable to some of our permanent stations installed in tunnels. The amplitude of the horizontal noise also appears to be highly correlated to wind speed recorded on site, even at long periods. The variable response of each vault to such external forcing can partly explain the variations of the seismic noise levels.
Innovations in connected health.
Singh, Kanwaljit; Kvedar, Joseph C
2009-01-01
Technological advancements in recent decades have made the concept of Connected Health feasible. These innovations include hardware innovations (such as wearable medical technology), and software (such as electronic personal health record systems e.g., Google Health and Microsoft HealthVault). Technology innovations must be accompanied by process innovations to truly add value. In health care that includes clinical process innovations and business process innovations. This chapter outlines how the healthcare system is being affected by innovations in connected health. It provides examples that illustrate the various categories of innovation and their impact. Now more than ever, health care reform is required in the U.S. The systems outlined in this chapter will allow care that is of high quality, while extending providers across more patients (i.e. increasing access) at a lower overall cost (improved efficiency).
Infrared studies of topological insulator systems
NASA Astrophysics Data System (ADS)
Post, Kirk; Chapler, Brian; Schafgans, Alex; Liu, Mengkun; Wu, Jih-Sheng; Richardella, Anthony; Lee, Joon Sue; Reijnders, Anjan; Lee, Yun Sang; He, Liang; Kou, Xufeng; Novak, Mario; Taskin, Alexey; Segawa, Kouji; Goldflam, Michael; Stinson, H. Theodore; Qi, Xiao Liang; Burch, Kenneth; Wang, Kang; Fogler, Michael; Samarth, Nitin; Ando, Yoichi; Basov, Dimitri
The theoretical prediction, and subsequent experimental realization, of topological insulator (TI) systems, has vaulted this new class of materials to the vanguard of condensed matter physics. Since their discovery, we have carried out a number of infrared studies on various TI systems, including Bi2Se3, Bi1-xSbx, and Bi2-xSbxTe3-ySey crystals as well as Bi2Se3 and (Bi,Sb)2Te3 thin films. A key element of these works is the revelation that the infrared response of Bi1-xSbx crystals and (Bi,Sb)2Te3 thin films possess a significant, or even dominant, component from the topologically protected surface states. I will review these works and discuss future prospects of measuring the surface state response through optical spectroscopy techniques
NASA Astrophysics Data System (ADS)
Coralie, Aubert; Anne, Paul; Stefano, Solarino; Sandrine, Roussel; Simone, Salimbeni; Pierre, Zangelmi; Glenn, Cougoulat; Yinshuang, Ai; Weiwei, Xu; Yumei, He; Liang, Zhao
2013-04-01
The CIFALPS (China-Italy-France Alps seismic survey) experiment is a common project of IGGCAS (China), ISTerre (France) and INGV (Italy). It aims at getting new high-resolution passive seismic data on the crustal and upper mantle structure of the southwestern Alps. In this framework, we have installed a temporary broadband seismic array across the southwestern Alps from the Rhône valley (France) to the Po plain (Italy). The main sub-array of CIFALPS is a 350-km long roughly linear profile of 46 stations trending WSW-ENE from Bollène (France) to north of Alessandria (Italy). The average station spacing is 10 km in the outer parts of the belt, and it reduces to 5 km in the internal Alps. Nine additional temporary stations located ~40 km to the north and south of the main profile complement the permanent broadband networks to improve the 3-D constraints on the deep structures. Stations are equipped with Nanometrics Taurus data acquisition systems, and Trillium 120P/A, CMG3-ESP or CMG40T broadband sensors. The array was installed in the summer of 2012 and will be operated at least to April 2013. Because our schedule was tight, we had to achieve site selections in only 3-4 months in spite of strong constraints on site location related to short interstation spacing. Most sites are located in basements of buildings for security reasons and mains power supply. As most sensors are true broadband (90s or 120s), we put much effort on vault design to insure good thermal insulation and low noise at long periods. The vaults also had to be easily and rapidly built and they should be easily and totally removed at the end of the experiment. We used the PQLX software for quality control of our sites and vault design. The performances of our vaults are good for the vertical component with noise levels at 100s period in the range -185 dB (low noise model) to -165 dB. They are less good for horizontal components (noise level close to high noise model at periods > 20s) due to atmospheric pressure and temperature variations. Stations located outside buildings do not have better performances at 100s than stations located in basements. Two of our six stations installed outside buildings are prone to mass centering problems due to tilting of the concrete slab in soft soil. For state-of-health control and data transmission, we are testing 2G and 3G communication modems at 4 remote stations but with limited success. Database preparation and management benefitted from the expertise of engineers of the seismic datacenter of ISTerre. The experience gained on all technical aspects of a temporary experiment will provide valuable input for the preparation of the future AlpArray project.
9. Interior of 'Pavilion Lounge' at north end of Second ...
9. Interior of 'Pavilion Lounge' at north end of Second Grandstand, showing vaulted ceilings, bar and spider chandelier. (May 1993) - Longacres, Second Grandstand, 1621 Southwest Sixteenth Street, Renton, King County, WA
8. Historic American Buildings Survey Ray Malinowski, Photographer JulyAugust 1968 ...
8. Historic American Buildings Survey Ray Malinowski, Photographer July-August 1968 FIRING PLATFORM STAIRWAY VAULT AND POSTERN - Bateria de San Antonio, San Carlos & Hovey Roads, Pensacola, Escambia County, FL
Macmillan, Alexandra; Lopez, Joseph; Mundinger, Gerhard S; Major, Melanie; Medina, Miguel A; Dorafshar, Amir H
2018-02-23
Late treatment of scaphocephaly presents challenges including need for more complex surgery to achieve desired head shape. Virtual surgical planning for total vault reconstruction may mitigate some of these challenges, but has not been studied in this unique and complex clinical setting. A retrospective chart review was conducted for patients with scaphocephaly who presented to our institution between 2000 and 2014. Patients presenting aged 12 months or older who underwent virtual surgical planning-assisted cranial vault reconstruction were included. Patient demographic, intraoperative data, and postoperative outcomes were recorded. Pre- and postoperative anthropometric measurements were obtained to document the fronto-occipital (FO) and biparietal (BP) distance and calculate cephalic index (CI). Virtual surgical planning predicted, and actual postoperative anthropometric measurements were compared. Five patients were identified who fulfilled inclusion criteria. The mean age was 50.6 months. One patient demonstrated signs of elevated intracranial pressure preoperatively. Postoperatively, all but one needed no revisional surgery (Whitaker score of 1). No patient demonstrated postoperative evidence of bony defects, bossing, or suture restenosis. The mean preoperative, simulated, and actual postoperative FO length was 190.3, 182, and 184.3 mm, respectively. The mean preoperative, simulated, and actual postoperative BP length was 129, 130.7, and 131 mm, respectively. The mean preoperative, simulated, and actual postoperative CI was 66, 72, and 71.3, respectively. Based on our early experience, virtual surgical planning using a modified Melbourne technique for total vault remodeling achieves good results in the management of late presenting scaphocephaly.
McElyea, Samantha D; Starbuck, John M; Tumbleson-Brink, Danika M; Harrington, Emily; Blazek, Joshua D; Ghoneima, Ahmed; Kula, Katherine; Roper, Randall J
2016-11-15
Trisomy 21 (Ts21) affects craniofacial precursors in individuals with Down syndrome (DS). The resultant craniofacial features in all individuals with Ts21 may significantly affect breathing, eating and speaking. Using mouse models of DS, we have traced the origin of DS-associated craniofacial abnormalities to deficiencies in neural crest cell (NCC) craniofacial precursors early in development. Hypothetically, three copies of Dyrk1a (dual-specificity tyrosine-(Y)-phosphorylation regulated kinase 1A), a trisomic gene found in most humans with DS and mouse models of DS, may significantly affect craniofacial structure. We hypothesized that we could improve DS-related craniofacial abnormalities in mouse models using a Dyrk1a inhibitor or by normalizing Dyrk1a gene dosage. In vitro and in vivo treatment with Epigallocatechin-3-gallate (EGCG), a Dyrk1a inhibitor, modulated trisomic NCC deficiencies at embryonic time points. Furthermore, prenatal EGCG treatment normalized some craniofacial phenotypes, including cranial vault in adult Ts65Dn mice. Normalization of Dyrk1a copy number in an otherwise trisomic Ts65Dn mice normalized many dimensions of the cranial vault, but did not correct all craniofacial anatomy. These data underscore the complexity of the gene–phenotype relationship in trisomy and suggest that changes in Dyrk1a expression play an important role in morphogenesis and growth of the cranial vault. These results suggest that a temporally specific prenatal therapy may be an effective way to ameliorate some craniofacial anatomical changes associated with DS.
Bigoni, L; Velemínská, J; Brůzek, J
2010-02-01
This article presents an approach for estimating the sexual dimorphism of adult crania using three-dimensional geometric morphometric methods. The study sample consisted of 139 crania of known sex (73 males and 66 females) belonging to persons who lived during the first half of the 20th century in Bohemia. The three-dimensional co-ordinates of 82 ecto-cranial landmarks and 39 semi-landmarks covering the midsagittal curve of the cranial vault were digitised using a MicroScribe G2X contact digitiser. The purposes of the investigation were to define the regions of the cranium where sexual dimorphism is most pronounced and to investigate the effectiveness of this method for determining sex from the shape of the cranium. The results demonstrate that it is better to analyse apportionable parts of the cranium rather than the cranium as a whole. Significant sexual differences (significance was determined using multivariate analysis of variance) were noted in the shape of the midsagittal curve of the vault, upper face, the region of the nose, orbits, and palate. No differences were recorded either in the shape of the cranium as a whole or in the regions of the base and the neurocranium. The greatest accuracy in determining sex was found in the region of the upper face (100% of study subjects correctly classified) and the midsagittal curve of the vault (99% of study subjects correctly classified). Copyright (c) 2010 Elsevier GmbH. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chintzoglou, Georgios; Vourlidas, Angelos; Savcheva, Antonia
We present the analysis of an unusual failed eruption captured in high cadence and in many wavelengths during the observing campaign in support of the Very high Angular resolution Ultraviolet Telescope ( VAULT2.0 ) sounding rocket launch. The refurbished VAULT2.0 is a Ly α ( λ 1216 Å) spectroheliograph launched on 2014 September 30. The campaign targeted active region NOAA AR 12172 and was closely coordinated with the Hinode and IRIS missions and several ground-based observatories (NSO/IBIS, SOLIS, and BBSO). A filament eruption accompanied by a low-level flaring event (at the GOES C-class level) occurred around the VAULT2.0 launch. Nomore » coronal mass ejection was observed. The eruption and its source region, however, were recorded by the campaign instruments in many atmospheric heights ranging from the photosphere to the corona in high cadence and spatial resolution. This is a rare occasion that enabled us to perform a comprehensive investigation on a failed eruption. We find that a rising Magnetic Flux Rope (MFR)-like structure was destroyed during its interaction with the ambient magnetic field, creating downflows of cool plasma and diffuse hot coronal structures reminiscent of “cusps.” We employ magnetofrictional simulations to show that the magnetic topology of the ambient field is responsible for the destruction of the MFR. Our unique observations suggest that the magnetic topology of the corona is a key ingredient for a successful eruption.« less
New technologies of mining stratal minerals and their computation
NASA Astrophysics Data System (ADS)
Beysembayev, K. M.; Reshetnikova, O. S.; Nokina, Z. N.; Teliman, I. V.; Asmagambet, D. K.
2018-03-01
The paper considers the systems of flat and volumetric modeling of controlling long-wall faces for schemes with rock collapse of the immediate and main roof and smooth lowering of the remaining layers, as well as in forming a vault over the face. Stress distributions are obtained for the reference pressure zone. They are needed for recognizing the active state of the long-wall face in the feedback mode. The project of the system “support - lateral rocks” is represented by a multidimensional network base. Its connections reflect the elements of the system or rocks, workings, supports with nodes and parts. The connections reflect the logic of the operation of machines, assemblies and parts, and the types of their mechanical connections. At the nodes of the base, there are built-in systems of object-oriented programming languages. This allows combining spatial elements of the system into a simple neural network.
2010-05-03
Assembly began April 1, 2010, for NASA Juno spacecraft in the high-bay cleanroom at Lockheed Martin in Denver, Colo. Workers are moving the radiation vault above a mock-up of the upper part of the spacecraft main body.
Rotating Juno for Integrating Instruments
2010-07-12
Once the radiation vault was installed on top of the propulsion module, NASA Juno spacecraft was lifted onto a large rotation fixture. The fixture allows the spacecraft to be turned for convenient access for integrating and testing instruments.
1. View Northeast, West Front, Elevation of Building 7 Note ...
1. View Northeast, West Front, Elevation of Building 7 Note opening to shaft to beer vault in foreground - Weissner Brewery, Building Nos. 6 & 7, 1700 North Gay Street, Baltimore, Independent City, MD
36. NORTH AND EAST SIDES OF MAIN STAIR HALL SHOWING ...
36. NORTH AND EAST SIDES OF MAIN STAIR HALL SHOWING STAIRWAY, NORTH SCULPTURE PANEL, AND CEILING VAULT; LOOKING NORTHEAST (Harms & Wieskamp) - Dairy Industry Building, Iowa State University campus, Ames, Story County, IA
7. NHP, Water Turbine Section, north end of east wall ...
7. NHP, Water Turbine Section, north end of east wall of 1908-1909 vaulted concrete standpipe foundation. View is to the Northeast. - Nunn Hydroelectric Plant, On Madison River, Ennis, Madison County, MT
Interior view, law library closer view to show painted details ...
Interior view, law library closer view to show painted details on the groin vaults - United States Department of Commerce, Bounded by Fourteenth, Fifteenth, and E streets and Constitution Avenue, Washington, District of Columbia, DC
9. DETAIL OF INTERIOR OF FRONT PORCH SHOWING FRONT ENTRY ...
9. DETAIL OF INTERIOR OF FRONT PORCH SHOWING FRONT ENTRY (LEFT) AND BLANK WALL (CENTER) CORRESPONDING TO LOCATION OF INTERIOR VAULTS. VIEW TO SOUTHEAST. - Boise Project, Boise Project Office, 214 Broadway, Boise, Ada County, ID
A novel technique to treat acquired Chiari I malformation after supratentorial shunting.
Potgieser, Adriaan R E; Hoving, Eelco W
2016-09-01
The acquired Chiari I malformation with abnormal cranial vault thickening is a rare late complication of supratentorial shunting. It poses a difficult clinical problem, and there is debate about the optimal surgical strategy. Some authors advocate supratentorial skull enlarging procedures while others prefer a normal Chiari decompression consisting of a suboccipital craniectomy, with or without C1 laminectomy and dural patch grafting. We illustrate three cases of symptomatic acquired Chiari I malformation due to inward cranial vault thickening. We describe a new surgical approach that appears to be effective in these patients. This approach includes the standard Chiari decompression combined with posterior fossa augmentation by thinning the occipital planum. Internal volume re-expansion of the posterior fossa by thinning the occipital planum appears to be an effective novel surgical strategy in conjunction with the standard surgical therapy of Chiari decompression.
Near-field transport of {sup 129}I from a point source in an in-room disposal vault
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolar, M.; Leneveu, D.M.; Johnson, L.H.
1995-12-31
A very small number of disposal containers of heat generating nuclear waste may have initial manufacturing defects that would lead to pin-hole type failures at the time of or shortly after emplacement. For sufficiently long-lived containers, only the initial defects need to be considered in modeling of release rates from the disposal vault. Two approaches to modeling of near-field mass transport from a single point source within a disposal room have been compared: the finite-element code MOTIF (A Model Of Transport In Fractured/porous media) and a boundary integral method (BIM). These two approaches were found to give identical results formore » a simplified model of the disposal room without groundwater flow. MOTIF has then been used to study the effects of groundwater flow on the mass transport out of the emplacement room.« less
TH-EF-BRB-11: Volumetric Modulated Arc Therapy for Total Body Irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ouyang, L; Folkerts, M; Hrycushko, B
Purpose: To develop a modern, patient-comfortable total body irradiation (TBI) technique suitable for standard-sized linac vaults. Methods: An indexed rotatable immobilization system (IRIS) was developed to make possible total-body CT imaging and radiation delivery on conventional couches. Treatment consists of multi-isocentric volumetric modulated arc therapy (VMAT) to the upper body and parallel-opposed fields to the lower body. Each isocenter is indexed to the couch and includes a 180° IRIS rotation between the upper and lower body fields. VMAT fields are optimized to satisfy lung dose objectives while achieving a uniform therapeutic dose to the torso. End-to-end tests with a randomore » phantom were used to verify dosimetric characteristics. Treatment plan robustness regarding setup uncertainty was assessed by simulating global and regional isocenter setup shifts on patient data sets. Dosimetric comparisons were made with conventional extended distance, standing TBI (cTBI) plans using a Monte Carlo-based calculation. Treatment efficiency was assessed for eight courses of patient treatment. Results: The IRIS system is level and orthogonal to the scanned CT image plane, with lateral shifts <2mm following rotation. End-to-end tests showed surface doses within ±10% of the prescription dose, field junction doses within ±15% of prescription dose. Plan robustness tests showed <15% changes in dose with global setup errors up to 5mm in each direction. Local 5mm relative setup errors in the chest resulted in < 5% dose changes. Local 5mm shift errors in the pelvic and upper leg junction resulted in <10% dose changes while a 10mm shift error causes dose changes up to 25%. Dosimetric comparison with cTBI showed VMAT-TBI has advantages in preserving chest wall dose with flexibility in leveraging the PTV-body and PTV-lung dose. Conclusion: VMAT-TBI with the IRIS system was shown clinically feasible as a cost-effective approach to TBI for standard-sized linac vaults.« less
1988-01-01
Settlements ........ 2.6-21 2.6.2.7.4.2 Total Settleme. t ... 2.6-21 2.6.2.7.4.3 Lateral Deformations ........ 2.6-22 2.6.2.7.5 Limits for Soil Loads and...otherwise specified, such as construction loads , etc. 2.1-2 F - Loads due to lateral and vertical pressure of incidental liquids. H - Loads due to lateral ...design loads , as well as forces and moments imposed by the continuity of the structural framing system. Columns should be designed to sustain all design
Neurosurgical rare disease: solitary plasmacytoma of the skull - case report and literature review.
Rizea, Radu Eugen; Popescu, Mihai; Gheorghiţă, Karina Lidia; Popescu, George; Neamţu, Marius Cristian; Busuioc, Cristina Jana; Ciurea, Alexandru Vlad
2018-01-01
Solitary extranevraxial plasmacytoma (SEP), as a clinical entity without signs of systemic myelomatosis, is extremely rare; it is difficult to find literature on the issue of patient management and proper course of action in the presence of associated pathology. The authors present a rare case of plasmacytoma of the skull vault associated with severe cardiac pathology, which made surgery extremely difficult and possible only through temporization of the interventions, as presented. We discuss our findings and opportunities for treatment in this case, which seemed unapproachable at presentation, in connection with the associated cardiac pathology. The case was followed-up for eight years with no recurrences.
Drudi, Laura; Press, Joshua Z; Lau, Susie; Gotlieb, Raphael; How, Jeffrey; Eniu, Ioana; Drummond, Nancy; Brin, Sonya; Deland, Claire; Gotlieb, Walter H
2013-06-01
Vaginal vault dehiscence following robotic-assisted hysterectomy for gynecologic cancer may be attributed to surgical techniques and postoperative therapeutic interventions. We searched for risk factors in patients with gynecologic cancers and complemented this with a literature review. Evaluation of prospectively gathered information on all consecutive robotic surgeries for gynecologic cancers was performed in a tertiary academic cancer center between December 2007 and March 2012. The literature was reviewed for articles relevant to "gynecologic oncology" and "robotics" with "vaginal cuff dehiscence" in the English and French languages. Respective authors were contacted to complete relevant information. Seven dehiscences were identified of 441 cases with established gynecologic cancers. The closures in these 7 were performed using interrupted 1-Vicryl (Ethicon Inc) (3/167; 1.8%), combination of interrupted 1-Vicryl and 1-Biosyn (Covidien Inc) (3/156, 1.9%), and V-Loc (Covidien Inc) (1/118, 0.8%) sutures. Associated risk factors included adjuvant chemotherapy and/or brachytherapy, early resumption of sexual activity, and low body mass index (mean, 23 ± 3.23 kg/m²). Dehiscences occurred regardless of suturing by staff or trainees. Review of operative videos did not reveal a detectable etiologic factor, such as excessive cautery damage to the vaginal cuff or shallow tissue sutured. All 7 colporrhexis repairs were performed through a vaginal approach without the need of laparoscopy or laparotomy. Postoperative chemotherapy, brachytherapy, and early resumption of sexual activities are risk factors for vaginal vault dehiscence. Surgical technique, particularly the use of delayed absorbable sutures, deserves further evaluation.
Cranial suture biology of the Aleutian Island inhabitants.
Cray, James; Mooney, Mark P; Siegel, Michael I
2011-04-01
Research on cranial suture biology suggests there is biological and taxonomic information to be garnered from the heritable pattern of suture synostosis. Suture synostosis along with brain growth patterns, diet, and biomechanical forces influence phenotypic variability in cranial vault morphology. This study was designed to determine the pattern of ectocranial suture synostosis in skeletal populations from the Aleutian Islands. We address the hypothesis that ectocranial suture synostosis pattern will differ according to cranial vault shape. Ales Hrdlicka identified two phenotypes in remains excavated from the Aleutian Island. The Paleo-Aleutians, exhibiting a dolichocranic phenotype with little prognathism linked to artifacts distinguished from later inhabitants, Aleutians, who exhibited a brachycranic phenotype with a greater amount of prognathism. A total of 212 crania representing Paleo-Aleuts and Aleutian as defined by Hrdlicka were investigated for suture synostosis pattern following standard methodologies. Comparisons were performed using Guttmann analyses. Results revealed similar suture fusion patterns for the Paleo-Aleut and Aleutian, a strong anterior to posterior pattern of suture fusion for the lateral-anterior suture sites, and a pattern of early termination at the sagittal suture sites for the vault. These patterns were found to differ from that reported in the literature. Because these two populations with distinct cranial shapes exhibit similar patterns of suture synostosis it appears pattern is independent of cranial shape in these populations of Homo sapiens. These findings suggest that suture fusion patterns may be population dependent and that a standardized methodology, using suture fusion to determine age-at-death, may not be applicable to all populations. Copyright © 2011 Wiley-Liss, Inc.
Atalay, Eray; Nongpiur, Monisha E; Baskaran, Mani; Sharma, Sourabh; Perera, Shamira A; Aung, Tin
2016-10-01
To compare ocular biometric and anterior segment parameters between the affected and fellow eye in subjects with acute primary angle closure (APAC). We evaluated 76 subjects with unilateral APAC who had undergone bilateral laser peripheral iridotomy before enrollment. Imaging was done using anterior segment optical coherence tomography and a customized software was used to measure the following: angle opening distance (AOD750); trabecular-iris space area (TISA750); iris thickness (IT750); iris curvature (ICURV); iris area (IAREA); anterior chamber depth; area and volume (ACD; ACA and ACV); anterior chamber width (ACW); anterior vault (ACD+LV); lens vault (LV); and pupil diameter (PD). We used A-scan ultrasonography to measure axial length (AL) and lens thickness (LT). Mean differences in ocular biometric and anterior segment parameters were assessed using linear mixed model adjusting for PD. A total of 53 subjects (36 females, 67.9%) with a mean age of 62.7 ± 8.1 years were analyzed after excluding 17 unanalyzable images in at least one eye. Affected eyes had shallower ACD, smaller ACA, ACV, anterior vault, TISA750, AOD750, and ICURV (all P < 0.05). Axial length, ACW, LV, LT, IAREA, and IT750 did not differ between the eyes. In the affected eyes, IT750 was significantly associated AOD750 (P < 0.05); whereas in the fellow eyes, IT750 and AL was predictive of AOD750 (all P < 0.05). Eyes with previous APAC had smaller anterior segment dimensions when compared with their fellow eyes. Iris thickness was the strongest predictor of angle width in both affected and fellow eyes.
Complex pattern of variation in neurocranial ontogeny revealed by CT-scanning.
Anzelmo, Marisol; Ventrice, Fernando; Kelmansky, Diana; Sardi, Marina
2018-05-01
The neurocranium of hominid species has been largely studied with reference to the midsagittal plane, with variations being attributed to brain evolution. By contrast, there is limited information on variation in non-midsagittal regions, which are the points of insertion of muscles and bony structures related to mastication. This work aims to analyze ontogenetic changes and sexual dimorphism (SD) in midsagittal and non-midsagittal neurocranial structures from a contemporary human sample comprising 138 computed tomography (CT) cranial images of individuals ranging from infants to adults. Morphology of the vault and the base was assessed by registering landmarks and semilandmarks, which were analyzed by geometric morphometrics, and the endocranial volume (EV). The results of regressions and Kruskal-Wallis test indicate that the major size and shape changes in both midsagittal and non-midsagittal regions occur during infancy and juvenility; shape changes are also associated with an increase in EV. The size of the midsagittal vault, the shape of the non-midsagittal vault and the size of the base show an extension of ontogenetic trajectories. Sexes show similar changes in shape but different changes in size. We conclude that brain growth appears to be an important factor influencing the morphology of the neurocranium, at least during infancy and childhood. Subsequent changes may be attributed to osteogenic activity and the differential growth of the brain lobes. Masticatory-related bony structures and muscles may not be strong enough factors to induce independent modifications in non-midsagittal structures. The small influence of the cranial muscles would explain why the human neurocranium is a quite integrated structure.
8. Photocopy of Station Grounding drawing showing floor plans (from ...
8. Photocopy of Station Grounding drawing showing floor plans (from the BPA Engineering Vault, Drawing 005319, 3 May 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR
Long-term Self-noise Estimates of Seismic Sensors From a High-noise Vault
NASA Astrophysics Data System (ADS)
Hicks, S. P.; Goessen, S.; Hill, P.; Rietbrock, A.
2017-12-01
To understand the detection capabilities of seismic stations and for reducing biases in ambient noise imaging, it is vital to assess the contribution of instrument self-noise to overall site noise. Self-noise estimates typically come from vault installations in continental interiors with very low ambient noise levels. However, this approach restricts the independent assessment of self-noise by individual end-users to assess any variations in their own instrument pools from nominal specifications given by manufacturers and from estimations given in comparative test papers. However, the calculation method should be adapted to variable installation conditions. One problem is that microseism noise can contaminate self-noise results caused by instrument misalignment errors or manufacturing limits; this effect becomes stronger where ambient noise is higher. Moreover, due to expected stochastic and time-varying sensor noise, estimates based on hand-picking small numbers of data segments may not accurately reflect true self-noise. We report on results from a self-noise test experiment of Güralp seismic instruments (3T, 3ESPC broadband seismometers, Fortis strong motion accelerometer) that were installed in the sub-surface vault of the Eskdalemuir Seismic Observatory in Scotland, UK over the period October 2016-August 2017. Due to vault's proximity to the ocean, secondary microseism noise is strong, so we efficiently compute the angle of misalignment that maximises waveform coherence with a reference sensor. Self-noise was calculated using the 3-sensor correlation technique and we compute probability density functions of self-noise to assess its spread over time. We find that not correcting for misalignments as low as 0.1° can cause self-noise to be artificially higher by up to 15 dB at frequencies of 0.1-1 Hz. Our method thus efficiently removes the effect of microseism contamination on self-noise; for example, it restores the minimum noise floor for a 360s - 50 Hz 3T to -195 dB at 0.2 Hz. Furthermore, based on the analysis of our calculated probability density functions, we find at long-periods (> 30 s) the average self-noise can be up to 5 dB higher than the minimum noise floor. We discuss the validity of these results in terms of making direct comparisons with self-noise results from much quieter installations.
Paula Menéndez, Lumila
2018-02-01
The aim of this study is to analyze the association between cranial variation and climate in order to discuss their role during the diversification of southern South American populations. Therefore, the specific objectives are: (1) to explore the spatial pattern of cranial variation with regard to the climatic diversity of the region, and (2) to evaluate the differential impact that the climatic factors may have had on the shape and size of the diverse cranial structures studied. The variation in shape and size of 361 crania was studied, registering 62 3D landmarks that capture shape and size variation in the face, cranial vault, and base. Mean, minimum, and maximum annual temperature, as well as mean annual precipitation, but also diet and altitude, were matched for each population sample. A PCA, as well as spatial statistical techniques, including kriging, regression, and multimodel inference were employed. The facial skeleton size presents a latitudinal pattern which is partially associated with temperature diversity. Both diet and altitude are the variables that mainly explain the skull shape variation, although mean annual temperature also plays a role. The association between climate factors and cranial variation is low to moderate, mean annual temperature explains almost 40% of the entire skull, facial skeleton and cranial vault shape variation, while annual precipitation and minimum annual temperature only contribute to the morphological variation when considered together with maximum annual temperature. The cranial base is the structure less associated with climate diversity. These results suggest that climate factors may have had a partial impact on the facial and vault shape, and therefore contributed moderately to the diversification of southern South American populations, while diet and altitude might have had a stronger impact. Therefore, cranial variation at the southern cone has been shaped both by random and nonrandom factors. Particularly, the influence of climate on skull shape has probably been the result of directional selection. This study supports that, although cranial vault is the cranial structure more associated to mean annual temperature, the impact of climate signature on morphology decreases when populations from extreme cold environments are excluded from the analysis. Additionally, it shows that the extent of the geographical scales analyzed, as well as differential sampling may lead to different results regarding the role of ecological factors and evolutionary processes on cranial morphology. © 2017 Wiley Periodicals, Inc.
5. View northwest at the northeastmost arch of culvert inlet ...
5. View northwest at the northeastmost arch of culvert inlet headwall, showing high inlet vault and interior drop arch. - Delaware & Raritan Canal, Ten Mile Run Culvert, 1.5 miles South of Blackwells Road, East Millstone, Somerset County, NJ
Under the Jade Vault Lei Feng Salutes Mark Twain.
ERIC Educational Resources Information Center
Krysl, Marilyn
1984-01-01
The experiences of a teacher who lectured undergraduates in the People's Republic of China on the American short story and taught a refresher course for Chinese teachers of English at the Tianjin Foreign Language Institute are presented. (Author/MLW)
78 FR 27472 - Notice of Passenger Facility Charge (PFC) Approvals and Disapprovals
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-10
... Approved For Collection And Use: Airfield lighting and vault. Runway 21 extension--preliminary design...--80 facility modification design and build-out. Access control enhancements. Security fence replacement. Airfield pavement survey. Jet bridge refurbishment. Security checkpoint modification. Friction...
Photographic copy of architectural drawing (original drawing located at the ...
Photographic copy of architectural drawing (original drawing located at the Panama Canal Commission Headquarters Building, Department of Engineering Vault, Balboa Heights, Republic of Panama). Rear elevation. - Quarry Heights, Officers' Quarters, Parkinson Lane, Balboa, Former Panama Canal Zone, CZ
Photographic copy of architectural drawing (original drawing located at the ...
Photographic copy of architectural drawing (original drawing located at the Panama Canal Commission Headquarters Building, Department of Engineering Vault, Balboa Heights, Republic of Panama). Longitudinal section. - Quarry Heights, Officers' Quarters, Parkinson Lane, Balboa, Former Panama Canal Zone, CZ
Photographic copy of architectural drawing (original drawing located at the ...
Photographic copy of architectural drawing (original drawing located at the Panama Canal Commission Headquarters Building, Department of Engineering Vault, Balboa Heights, Republic of Panama). First floor plan. - Quarry Heights, Officers' Quarters, Parkinson Lane, Balboa, Former Panama Canal Zone, CZ
Photographic copy of architectural drawing (original drawing located at the ...
Photographic copy of architectural drawing (original drawing located at the Panama Canal Commission Headquarters Building, Department of Engineering Vault, Balboa Heights, Republic of Panama). Front elevation. - Quarry Heights, Officers' Quarters, Parkinson Lane, Balboa, Former Panama Canal Zone, CZ
Photographic copy of architectural drawing (original drawing located at the ...
Photographic copy of architectural drawing (original drawing located at the Panama Canal Commission Headquarters Building, Department of Engineering Vault, Balboa Heights, Republic of Panama). Left side elevation. - Quarry Heights, Officers' Quarters, Parkinson Lane, Balboa, Former Panama Canal Zone, CZ
Photographic copy of architectural drawing (original drawing located at the ...
Photographic copy of architectural drawing (original drawing located at the Panama Canal Commission Headquarters Building, Department of Engineering Vault, Balboa Heights, Republic of Panama), Right side elevation. - Quarry Heights, Officers' Quarters, Parkinson Lane, Balboa, Former Panama Canal Zone, CZ
Photographic copy of architectural drawing (original drawing located at the ...
Photographic copy of architectural drawing (original drawing located at the Panama Canal Commission Headquarters Building, Department of Engineering Vault, Balboa Heights, Republic of Panama). Second floor plan. - Quarry Heights, Officers' Quarters, Parkinson Lane, Balboa, Former Panama Canal Zone, CZ
Detail view to show richness of materials such as the ...
Detail view to show richness of materials such as the Fourteenth Street vestibule with its gilded groin-vaulted ceiling - United States Department of Commerce, Bounded by Fourteenth, Fifteenth, and E streets and Constitution Avenue, Washington, District of Columbia, DC
NREL Testing Erigo's and EaglePicher's Microgrid Energy Storage System |
EaglePicher's Microgrid Energy Storage System NREL researchers are testing an energy storage system for a contains three independently controllable energy storage technologies. Photo of energy storage system hardware in a laboratory Photo by Dennis Schroeder Microgrids-and effective storage systems supporting them
NASA Astrophysics Data System (ADS)
Dewynter, V.; Rougeault, S.; Magne, S.; Ferdinand, P.; Vallon, F.; Avallone, L.; Vacher, E.; De Broissia, M.; Canepa, Ch.; Poulain, A.
2009-10-01
Safety while tunneling is one of the main challenges for underground constructions, avoiding confinement losses, which remain an important risk for public works, leading to additional delays and high insurance costs. In such applications, usual surface instrumentations cannot be set up because of high building density in many overcrowded cities. Tunnelling deals with the challenge of requiring ground surface undisturbed. One original concept proposed in the framework of the European Tunconstruct project, consists in very early settlement detection close to the tunnel vault and before any detectable effect on the surface. The adopted solution is to set-up a sensing element inserted into a directional drilling excavated above the foreseen tunnel. The methodology is based on the well known Brillouin Optical Time Domain Reflectometry (B-OTDR) in singlemode optical fibres and a special cable design dedicated to bending measurement. Two cables, based on different industrial manufacturing processes, have been developed taking into account the strain sensitivity required, the flexibility and the robustness for borehole installation, a low power attenuation and storage on a drum. Industrial prototypes have been manufactured and validated with tests in open air where settlement profiles geometry can be accurately controlled. Demonstration on job site took place on The Greater Cairo Metro Line 3 (CML3) at the beginning of 2009.
The SERI solar energy storage program
NASA Technical Reports Server (NTRS)
Copeland, R. J.; Wright, J. D.; Wyman, C. E.
1980-01-01
In support of the DOE thermal and chemical energy storage program, the solar energy storage program (SERI) provides research on advanced technologies, systems analyses, and assessments of thermal energy storage for solar applications in support of the Thermal and Chemical Energy Storage Program of the DOE Division of Energy Storage Systems. Currently, research is in progress on direct contact latent heat storage and thermochemical energy storage and transport. Systems analyses are being performed of thermal energy storage for solar thermal applications, and surveys and assessments are being prepared of thermal energy storage in solar applications. A ranking methodology for comparing thermal storage systems (performance and cost) is presented. Research in latent heat storage and thermochemical storage and transport is reported.
NASA Astrophysics Data System (ADS)
Hafner, Katrin
2017-04-01
The goal of the Global Seismographic Network (GSN) is to provide the highest possible data quality and dynamic recording range in support of scientific needs. Considerable effort is made at each GSN seismic station site to achieve the lowest noise performance possible under local conditions. We continue to strive for higher data quality with a combination of new sensors and improved installation techniques. Most seismometers are installed either in 100 m deep steel-cased boreholes or in vaults tunneled underground. A few vaults are built at the surface or on the foundation of a building. All vault installations have a concrete pier, mechanically isolated from the floor, upon which the seismometers are placed. Many sites are now nearly 30 years old, and the GSN is investing in civil works at several stations to keep them in good condition or make critical repairs. Using GSN data from inception to the present, we will present analyses that demonstrate how successful these sensor installation strategies have been and describe ongoing experiments at GSN testing facilities to evaluate the best, most cost effective strategy to modernize existing GSN facilities. To improve sensor performance at some vault sites, we will employ new sensor installation strategies. Years of experience operating the GSN and the USArray Transportable Array, along with focused testing of emplacement strategies, show that the vulnerability of a sensor's horizontal components to tilt can be mitigated if the sensor package is buried at even shallow depth. At selected vault installations, shallow boreholes will be drilled to accommodate recently developed borehole VBB sensor models. The incremental cost of modern VBB instruments over standard BB models is small, and we expect to be able to preserve the GSN's crucial very broad bandwidth while improving noise performance and reliability using this strategy. A crucial link in making GSN station data available to the scientific community is the IRIS Data Management Center, which not only maintains the data archive, but also provides easy, rapid, and open access to data recorded from seconds to decades ago. All data flow to the IRIS DMC through the UCSD or ASL Data Collection Centers (DCCs). The DCCs focus on delivering data to the DMC, maintaining correct metadata for GSN stations, reviewing data quality from the stations that ASL and UCSD operate, and addressing circumstances that require special data handling, such as back filling following telemetry outages. Key to the high quality of the GSN data is the direct feedback on data quality problems identified by the DCC analysts to the network operations staff and field engineers. Aging of GSN equipment and station infrastructure has resulted in renewed emphasis on using data quality control tools such as MUSTANG. These tools allow the network operators to routinely monitor and analyze waveform data to detect and track problems and develop short and longer term action plans for improving network data quality. We will present summary data quality metrics for the GSN as obtained via these quality assurance tools.
Proceedings of the DOE chemical energy storage and hydrogen energy systems contracts review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Sessions were held on electrolysis-based hydrogen storage systems, hydrogen production, hydrogen storage systems, hydrogen storage materials, end-use applications and system studies, chemical heat pump/chemical energy storage systems, systems studies and assessment, thermochemical hydrogen production cycles, advanced production concepts, and containment materials. (LHK)
6. Photograph of extant ink on linen drawings (original drawings ...
6. Photograph of extant ink on linen drawings (original drawings held in the vault of the Office of the State Architect in Sacramento) SECOND FLOOR FRAMING PLAN, AUGUST 1922 - California State Printing Office, 1020 O Street, Sacramento, Sacramento County, CA
5. Photograph of extant ink on linen drawings (original drawings ...
5. Photograph of extant ink on linen drawings (original drawings held in the vault of the Office of the State Architect in Sacramento) FIRST FLOOR FRAMING PLAN, AUGUST 1922 - California State Printing Office, 1020 O Street, Sacramento, Sacramento County, CA
7. Photograph of extant ink on linen drawings (original drawings ...
7. Photograph of extant ink on linen drawings (original drawings held in the vault of the Office of the State Architect in Sacramento) DETAILS OF FLAT SLAB CONSTRUCTION, AUGUST 1922 - California State Printing Office, 1020 O Street, Sacramento, Sacramento County, CA
NASA Astrophysics Data System (ADS)
Boitani, P.
2011-06-01
From Homer to the Bible looking at the heavenly vault is an enchanted moment in human life. It produces that wonder which Aristotle maintains is the beginning of the love of wisdom, that is to say of philosophy, science, and philomythia-the love of myth: poetry.
Photographic copy of architectural drawing (original drawing located at the ...
Photographic copy of architectural drawing (original drawing located at the Panama Canal Commission Headquarters Building, Department of Engineering Vault, Balboa Heights, Republic of Panama). Details of bookshelves and pilasters. - Quarry Heights, Officers' Quarters, Parkinson Lane, Balboa, Former Panama Canal Zone, CZ
75 FR 69473 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-12
... NATIONAL ARCHIVES AND RECORDS ADMINISTRATION Agency Information Collection Activities: Submission for OMB Review; Comment Request AGENCY: National Archives and Records Administration (NARA). ACTION... effectiveness of the Public Vaults and its several exhibits in enhancing visitors' understanding that records...
Identification, analysis, and remedial treatment of low guardrail in Virginia.
DOT National Transportation Integrated Search
1981-01-01
Guardrails that are too low may fail to safely redirect errant vehicles; instead, the vehicles may vault the guardrails, resulting in severe accidents. An analysis of data on a small sample of guardrails throughout-Virginia showed that over 80% of th...
48 CFR 652.236-70 - Accident Prevention.
Code of Federal Regulations, 2014 CFR
2014-10-01
...; (iii) Trenching or other excavation greater than one (1) meter in depth; (iv) Earth moving equipment... health such as water tanks, transformer vaults, sewers, cisterns, etc.); (vii) Hazardous materials—a... the corrective actions required. This notice, when delivered to the contractor or the contractor's...
48 CFR 652.236-70 - Accident Prevention.
Code of Federal Regulations, 2011 CFR
2011-10-01
...; (iii) Trenching or other excavation greater than one (1) meter in depth; (iv) Earth moving equipment... health such as water tanks, transformer vaults, sewers, cisterns, etc.); (vii) Hazardous materials—a... the corrective actions required. This notice, when delivered to the contractor or the contractor's...
48 CFR 652.236-70 - Accident Prevention.
Code of Federal Regulations, 2012 CFR
2012-10-01
...; (iii) Trenching or other excavation greater than one (1) meter in depth; (iv) Earth moving equipment... health such as water tanks, transformer vaults, sewers, cisterns, etc.); (vii) Hazardous materials—a... the corrective actions required. This notice, when delivered to the contractor or the contractor's...
48 CFR 652.236-70 - Accident Prevention.
Code of Federal Regulations, 2013 CFR
2013-10-01
...; (iii) Trenching or other excavation greater than one (1) meter in depth; (iv) Earth moving equipment... health such as water tanks, transformer vaults, sewers, cisterns, etc.); (vii) Hazardous materials—a... the corrective actions required. This notice, when delivered to the contractor or the contractor's...
Interior building details of Building A, dungeon cell adjacent to ...
Interior building details of Building A, dungeon cell adjacent to northwest cell: granite and brick threshold, poured concrete floors, plastered finished walls, vaulted veiling; northwesterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Spacecraft cryogenic gas storage systems
NASA Technical Reports Server (NTRS)
Rysavy, G.
1971-01-01
Cryogenic gas storage systems were developed for the liquid storage of oxygen, hydrogen, nitrogen, and helium. Cryogenic storage is attractive because of the high liquid density and low storage pressure of cryogens. This situation results in smaller container sizes, reduced container-strength levels, and lower tankage weights. The Gemini and Apollo spacecraft used cryogenic gas storage systems as standard spacecraft equipment. In addition to the Gemini and Apollo cryogenic gas storage systems, other systems were developed and tested in the course of advancing the state of the art. All of the cryogenic storage systems used, developed, and tested to date for manned-spacecraft applications are described.
Tang, Siwei; Bai, Chen; Yang, Pengyuan; Chen, Xian
2013-01-01
Major vault protein (MVP) is the predominant constituent of the vault particle, the largest known ribonuclear protein complex. Although emerging evidences have been establishing the links between MVP (vault) and multidrug resistance (MDR), little is known regarding exactly how the MDR activity of MVP is modulated during cellular response to drug-induced DNA damage (DDR). Bleomycin (BLM), an anti-cancer drug, induces DNA double-stranded breaks (DSBs) and consequently triggers the cellular DDR. Due to its physiological implications in hepatocellular carcinoma (HCC) and cell fate decision, 14-3-3ε was chosen as the pathway-specific bait protein to identify the critical target(s) responsible for HCC MDR. By using LC-MS/MS-based proteomic approach, MVP was first identified in the BLM-induced 14-3-3ε interactome formed in HCC cells. Biological characterization revealed that MVP possesses specific activity to promote the resistance to the BLM-induced DDR. On the other hand, 14-3-3ε enhances BLM-induced DDR by interacting with MVP. Mechanistic investigation further revealed that 14-3-3ε, in a phosphorylation-dependent manner, binds to the phosphorylated sites at both Thr52 and Ser864 of the monomer of MVP. Consequently, the phosphorylation-dependent binding between 14-3-3ε and MVP inhibits the drug-resistant activity of MVP for an enhanced DDR to BLM treatment. Our findings provide an insight into the mechanism underlying how the BLM-induced interaction between 14-3-3ε and MVP modulates MDR, implicating novel strategy to overcome the chemotherapeutic resistance through interfering specific protein-protein interactions. PMID:23590642
NASA Astrophysics Data System (ADS)
Lluveras, A.; Boularand, S.; Roqué, J.; Cotte, M.; Giráldez, P.; Vendrell-Saz, M.
2008-01-01
In this paper seventeenth century gilded paintings from the crypt of Sant Benet de Bages, a medieval monastery in the Catalonia region of Spain, near Barcelona, have been studied. Cross sections from two different gilded decorations were studied by means of optical microscopy and electron microscopy and EDS to determine the statigraphy and elemental composition, and by means of FTIR coupled to a microscope to determine the binding media associated to each layer. These preliminary results demonstrated that gilded decorations were made by the application of a gold foil on a mordant substrate on a gypsum base, while the mouldings of the vaults seem to be gilded on a bol with a glaze on top of the gold leaf. It is interesting to notice that the first remained unaltered, while the gilded vault mouldings look almost black, due to the darkening of the organic material. To elucidate the causes involved in the darkening of the sample from the vaults a set of synchrotron μXRD and μFTIR experiments have been carried out on these samples at the ESRF (ID18F and ID21, respectively). High brightness and small spot working conditions revealed the development and distribution of calcium oxalates in the binding media, which seem to be responsible for the darkening. Results point out the fact that weddellite (CaC2O4·2H2O) is the phase formed in those layers where organic material has also been identified or at least it would be supposed to be by bibliographic sources and not necessarily those superficial as it would have been suggested due to the similarities with patinas formation.
[Gymnastic school sport injuries--aspects of preventive measures].
Knobloch, K; Jagodzinski, M; Haasper, C; Zeichen, J; Krettek, C
2006-06-01
Gymnastic school sport injuries account for a significant morbidity and mortality among children and adolescents. Preventive issues may be derived from a thorough in-depth analysis of the pattern and circumstances of gymnastic injuries. During a school year among 3993 schools in 43 889 classes with 993 056 pupils 2234 school sport injuries have been reported to the Gemeinde Unfall Versicherung (GUV) Niedersachsen, Germany. Gymnastic sport injuries account for 18 % (403 accidents), which is second after ball sports injuries. Regarding the distribution of the gymnastic disciplines, vault was the major discipline with 34 %, followed by floor exercise (21.3 %), mini- and competition trampoline (16.8 %), and parallel bars (8.2 %). The analysis of the type of injury during vault accidents revealed contusion (31 %) as the predominant injury, followed by sprains (15.4 %), and fractures (15.4 %). Floor exercise injuries distributed among distorsions (26.7 %), contusions (18.6 %), muscle tears (14 %). Back injuries especially of the cervical and thoracic spine, accounted for 40 % of all their injuries. Minor head injuries account for 4.7 % of all floor exercise injuries. Mini-trampoline injuries distribute among contusions (30 %), fractures (22.5 %), distorsions (7.5 %). 21.8 % collisions were noted against a box in comparison to 6.8 % in case of the horse. Gymnast injuries account for a significant number of all school sport related injuries. Vault and floor exercise account for the vast majority of all injuries, with alarming high numbers of spine injuries during floor exercise and mini-trampoline. A preservation of a high level of attention during a sport lesson, safety measures including appropriate mats and landing zones are mandatory to reduce injuries. Muscle injuries and ankle sprains can be prevented by a prospective proprioceptive training intervention to be implemented in school sports.
Wiebe, Ericka; Easton, Harry; Thomas, Gillian; Barbera, Lisa; D'Alimonte, Laura; Ravi, Ananth
2015-01-01
A novel customized vaginal brachytherapy mould technique has been developed for clinical use. This image-guided technique provides a brachytherapy applicator solution for irregular vaginal vault configuration and/or a wide vaginal apex relative to the vaginal introitus that would be sub-optimally treated with standard cylinders. The customized vaginal applicator is generated by the following process: CT images are obtained with contrast-soaked vaginal packing in situ to highlight unique anatomical detail. A 3-dimensional digital model is developed from the images and subsequently converted into a custom applicator with the use of stereolithography, which is an additive manufacturing technique whereby layers 50-100 μm thick of resin are deposited and polymerized using a laser to create intricate 3-dimensional objects. The density of the applicator and the dose delivered using the custom applicator were both measured to ensure accurate dosimetry. The CT-based densities of a clinical vaginal cylinder and the cylinder generated using stereolithography were 1.29 ± 0.06 g/cm(3) vs 1.28 ± 0.01 g/cm(3), respectively. The mean measured dose from a representative stereolithographed applicator normalized to dose measured for a single plastic catheter was 99.8 ± 4.2%. In patient dosimetric results indicate improved coverage of the lateral aspect of vaginal vault with the custom cylinder relative to the standard cylinder; 700 cGy vs 328 cGy, respectively, at a representative lateral vaginal dose point, while simultaneously achieving relatively narrow dose distribution in the anterior/posterior direction. Stereolithographic applicator production was available within a clinically acceptable timeframe, and its clinical feasibility and utility has been demonstrated. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Antovska, S V; Dimitrov, D G
2006-01-01
The effect of a new modification of the Mc Call operation, vaginosacral colpopexy (VSC) was evaluated in the group of 32 patients. Due to our bad experience with transabdominal lumbosacral colpopexy, we tried to find out another solution. VSC using the mobilized vaginosacral ligaments as sliding grafts (two sutures through the vaginosacral ligaments and posterior vaginal wall and the third suture through the uterosacral ligaments) for vault prolapse was performed in the group of 32 patients. Before operation, the median stage of prolapse was: stage III (range, 0-IV) for anterior site; stage II (range, 0-IV) for posterior site; stage I (range, 0-IV) of the apical segment, and stage III (range 0-IV) for the most severe segment of prolapse. The mean follow-up was 24.5 months (range 9-42 months). There were no intraoperative injuries of the bladder, ureter, rectum or small bowel. At the final follow-up, the mean stage of the prolapse was following: stage 0 (range, 0-III) for anterior site, posterior site and the most severe segment of prolapse; and stage 0 (range, 0-I) of the apical segment. The total vaginal length (tvl) increased significantly (p < 0.001) (Valsalva maneuver) (Vm) and (p < 0.001) (Pozzi maneuver) (Pm) from the preoperative mean value of 3.20 +/- 1.18 (Vm) and 2.70 +/- 0.92 (Pm) to (- 8.33 +/- 0.77) (Vm) and (-7.82 +/- 0.89) (Pm). All 8 patients with genuine stress incontinence, became continent. 3 of 4 patients with potential urinary incontinence required Marshal-Marchetti operation for persistent stress incontinence. VSC seems to be quick, safe and effective procedure for vault prolapse (Tab. 5, Fig. 8, Ref. 31).
Phuc, P D; Konradsen, F; Phuong, P T; Cam, P D; Dalsgaard, A
2006-01-01
The ancient practice of applying latrine wastes to agricultural land has maintained soil fertility in Vietnam for several centuries but may be associated with health risks if the wastes are inadequately treated before usage. This study aimed at investigating the perceptions and handling practices using latrine wastes as fertilizers in a community in central Vietnam. Information was collected through structured questionnaire interviews administered to 75 farming households, focus group discussions, and key informant interviews. The majority (64%) of households had a single vault latrine, a possession that was associated with low income (chi2= 12.45; p < 0.05). Most households (85%) used latrine waste in agriculture that was composted before usage (98%). Households often mixed the composted excreta with kitchen ashes and powdered lime likely to increase pH and pathogen die-off. About 28% of households that were applying latrine waste as fertilizer composted three to six months, and only 11 (18%) households composted human excreta for more than the recommended six months. Households with double vault latrines were 7.8 (chi2= 9.4; p<0.05) times more likely to compost human excreta more than six months as compared with households having single vault latrine. Most farmers distributed the latrine wastes with bare hands (66%) because of convenience during application. Respondents with a high educational level used protective gloves more often when distributing latrine wastes in the fields compared to respondents with a low educational level (chi2 = 7.6; p<0.05). If any negative health impacts of latrine waste use in agriculture are to be reduced, then it is suggested that sustainable interventions should take into consideration farmers current excreta-use practices.
Miller, R.; Black, W.; Miele, M.; Morgan, T.; Ivanov, J.; Xia, J.; Peterie, S.
2011-01-01
A high-resolution seismic reflection investigation mapped reflectors and identified characteristics potentially influencing the interpretation of the hydrogeology underlying a portion of the Oxnard Plain in Ventura County, California. Design and implementation of this study was heavily influenced by high levels of cultural noise from vehicles, power lines, roads, manufacturing facilities, and underground utilities/vaults. Acquisition and processing flows were tailored to this noisy environment and relatively shallow target interval. Layering within both upper and lower aquifer systems was delineated at a vertical resolution potential of around 2.5 m at 350 m depth. ?? 2011 Society of Exploration Geophysicists.
Stand-alone digital data storage control system including user control interface
NASA Technical Reports Server (NTRS)
Wright, Kenneth D. (Inventor); Gray, David L. (Inventor)
1994-01-01
A storage control system includes an apparatus and method for user control of a storage interface to operate a storage medium to store data obtained by a real-time data acquisition system. Digital data received in serial format from the data acquisition system is first converted to a parallel format and then provided to the storage interface. The operation of the storage interface is controlled in accordance with instructions based on user control input from a user. Also, a user status output is displayed in accordance with storage data obtained from the storage interface. By allowing the user to control and monitor the operation of the storage interface, a stand-alone, user-controllable data storage system is provided for storing the digital data obtained by a real-time data acquisition system.
Thermal Storage Applications Workshop. Volume 2: Contributed Papers
NASA Technical Reports Server (NTRS)
1979-01-01
The solar thermal and the thermal and thermochemical energy storage programs are described as well as the technology requirements for both external (electrical) and internal (thermal, chemical) modes for energy storage in solar power plants. Specific technical issues addressed include thermal storage criteria for solar power plants interfacing with utility systems; optimal dispatch of storage for solar plants in a conventional electric grid; thermal storage/temperature tradeoffs for solar total energy systems; the value of energy storage for direct-replacement solar thermal power plants; systems analysis of storage in specific solar thermal power applications; the value of seasonal storage of solar energy; criteria for selection of the thermal storage system for a 10 MW(2) solar power plant; and the need for specific requirements by storage system development teams.
Thermal energy storage devices, systems, and thermal energy storage device monitoring methods
Tugurlan, Maria; Tuffner, Francis K; Chassin, David P.
2016-09-13
Thermal energy storage devices, systems, and thermal energy storage device monitoring methods are described. According to one aspect, a thermal energy storage device includes a reservoir configured to hold a thermal energy storage medium, a temperature control system configured to adjust a temperature of the thermal energy storage medium, and a state observation system configured to provide information regarding an energy state of the thermal energy storage device at a plurality of different moments in time.
Open systems storage platforms
NASA Technical Reports Server (NTRS)
Collins, Kirby
1992-01-01
The building blocks for an open storage system includes a system platform, a selection of storage devices and interfaces, system software, and storage applications CONVEX storage systems are based on the DS Series Data Server systems. These systems are a variant of the C3200 supercomputer with expanded I/O capabilities. These systems support a variety of medium and high speed interfaces to networks and peripherals. System software is provided in the form of ConvexOS, a POSIX compliant derivative of 4.3BSD UNIX. Storage applications include products such as UNITREE and EMASS. With the DS Series of storage systems, Convex has developed a set of products which provide open system solutions for storage management applications. The systems are highly modular, assembled from off the shelf components with industry standard interfaces. The C Series system architecture provides a stable base, with the performance and reliability of a general purpose platform. This combination of a proven system architecture with a variety of choices in peripherals and application software allows wide flexibility in configurations, and delivers the benefits of open systems to the mass storage world.
9. Photocopy of Reinforced Concrete Details drawing (from the BPA ...
9. Photocopy of Reinforced Concrete Details drawing (from the BPA Engineering Vault, Drawing C13-J2-342-D1, Sheet 6, 13 March 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR
44. Photographic copy of original construction drawing, dated August 1911 ...
44. Photographic copy of original construction drawing, dated August 1911 (from paper-copy of aperture-card negative at Bureau of Reclamation, Pacific Northwest Regional Office, Boise, ID). PLANS AND SECTIONS OF VAULTS. - Boise Project, Boise Project Office, 214 Broadway, Boise, Ada County, ID
78 FR 57213 - Notice of Passenger Facility Charge (PFC) Approvals and Disapprovals
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-17
... of Projects Approved for Collection and Use: Traffic survey design. Terminal curbside canopy... update. Gulfstream Road/tunnel design. Airfield electrical vault design. Taxiway A design. Taxiway H design. Decision Date: September 18, 2012. FOR FURTHER INFORMATION CONTACT: Robert Rau, Atlanta Airports...
21. Photocopy of engineering drawing, April 10, 1958 (original drawing ...
21. Photocopy of engineering drawing, April 10, 1958 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering Vault). READINESS CREW BUILDING, RAMP DETAILS - Fairchild Air Force Base, Bomber Alert Facility, 803G South Taxi Way, Spokane, Spokane County, WA
25. Photocopy of engineering drawing, January, 1988 (original drawing located ...
25. Photocopy of engineering drawing, January, 1988 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering Vault). EXTERIOR ELEVATIONS (northeast and southeast) - Fairchild Air Force Base, Bomber Alert Facility, 803G South Taxi Way, Spokane, Spokane County, WA
26. Photocopy of engineering drawing, March 3, 1988 (original drawing ...
26. Photocopy of engineering drawing, March 3, 1988 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering Vault). EXTERIOR ELEVATIONS (southwest and northwest) - Fairchild Air Force Base, Bomber Alert Facility, 803G South Taxi Way, Spokane, Spokane County, WA
20. Photocopy of engineering drawing, April 10, 1958 (original drawing ...
20. Photocopy of engineering drawing, April 10, 1958 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering Vault). READINESS CREW BUILDING, ELEVATIONS - Fairchild Air Force Base, Bomber Alert Facility, 803G South Taxi Way, Spokane, Spokane County, WA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-10
... the cranial vault, the right arm, the sacrum, the pelvis, and both legs. The sex of this individual is female based on traits associated with the pelvis. A specific age range determination was not possible...
Code of Federal Regulations, 2010 CFR
2010-07-01
... is covered with earth, sand, gravel, asphalt, or other material. A bunkered tank is considered an... below grade and covered with earth, sand, gravel, asphalt, or other material. Containers in vaults...- or short-term, in the chemical or physical quality or the viability of a natural resource resulting...
Gopal, Venu; Ganesh, Praveen; Nagarjuna, Muralidhara; Kumar, Kiran; Shetty, Samarth; Salins, Paul C.
2015-01-01
Aim To fabricate a cost effective, indigenous and simple orthotics helmet for post-operative cranial molding in patients with craniosynostosis surgery. Methods We present a case of 15 month old infant with secondary cranial vault deformity. Cranial vault remodeling surgery involving the posterior skull was planned and executed to increase the posterior gap, so that brain growth would be facilitated towards this empty space. Materials such as thermoplastic sponge, thermoplastic ionomer resin sheet, soft sponge and Velcro straps are used to fabricate a cranial orthotics helmet. Results We have successfully used the above materials to fabricate the orthotics helmet for post-operative cranial molding. Conclusion The technique described in this article is simple and cost effective. It can be custom made according to the demands of the surgical technique and the type of synostosis. It favors an individualistic prognosis, and proves worthwhile as every synostosis requires a unique treatment plan. It is an excellent adjuvant to craniosynostosis remodeling surgery. PMID:26258018
Calibration under uncertainty for finite element models of masonry monuments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atamturktur, Sezer,; Hemez, Francois,; Unal, Cetin
2010-02-01
Historical unreinforced masonry buildings often include features such as load bearing unreinforced masonry vaults and their supporting framework of piers, fill, buttresses, and walls. The masonry vaults of such buildings are among the most vulnerable structural components and certainly among the most challenging to analyze. The versatility of finite element (FE) analyses in incorporating various constitutive laws, as well as practically all geometric configurations, has resulted in the widespread use of the FE method for the analysis of complex unreinforced masonry structures over the last three decades. However, an FE model is only as accurate as its input parameters, andmore » there are two fundamental challenges while defining FE model input parameters: (1) material properties and (2) support conditions. The difficulties in defining these two aspects of the FE model arise from the lack of knowledge in the common engineering understanding of masonry behavior. As a result, engineers are unable to define these FE model input parameters with certainty, and, inevitably, uncertainties are introduced to the FE model.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-01-01
This Environmental Assessment (EA) has been prepared by the Department of Energy (DOE) to assess the potential environmental impacts associated with the construction, operation and decontamination and decommissioning (D&D) of the Waste Segregation Facility (WSF) for the sorting, shredding, and compaction of low-level radioactive waste (LLW) at the Savannah River Site (SRS) located near Aiken, South Carolina. The LLW to be processed consists of two waste streams: legacy waste which is currently stored in E-Area Vaults of SRS and new waste generated from continuing operations. The proposed action is to construct, operate, and D&D a facility to process low-activity job-controlmore » and equipment waste for volume reduction. The LLW would be processed to make more efficient use of low-level waste disposal capacity (E-Area Vaults) or to meet the waste acceptance criteria for treatment at the Consolidated Incineration Facility (CIF) at SRS.« less
Concordia CCD - A Geoscope station in continental Antarctica
NASA Astrophysics Data System (ADS)
Maggi, A.; Lévêque, J.; Thoré, J.; Bes de Berc, M.; Bernard, A.; Danesi, S.; Morelli, A.; Delladio, A.; Sorrentino, D.; Stutzmann, E.; Geoscope Team
2010-12-01
Concordia (Dome C, Antarctica) has had a permanent seismic station since 2005. It is run by EOST and INGV in collaboration with the French and Italian polar institutes (IPEV and PNRA). It is installed in an ice-vault, at 12m depth, distant 1km from the permanent scientific base at Concordia. The temperature in the vault is a constant -55°C. The data quality at the station has improved continuously since its installation. In 2007, the station was declared at ISC as an open station with station code CCD (ConCorDia), with data available upon request. It is only the second permanent station in the Antarctic continent, after South Pole. In 2010, CCD was included in the Geoscope network. Data from CCD starting in 2007 are now freely available from the Geoscope Data Center and IRIS. We present an analysis of the data quality at CCD, and describe the technical difficulties of operating an observatory-quality seismic station in the extreme environmental conditons present in continental Antarctica.
Nondestructive Analysis of MET-5 Paint Can at TA35 Building 2 A-Wing Vault
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desimone, David J.; Vo, Duc Ta
In Building 2 A-wing vault MET-5 has some drums and other packages they wanted NEN-1 help identifying nondestructively. Measurements using a mechanically cooled portable high-purity germanium HPGe Ortec detective were taken of a paint can container labeled DU-2A to determine if any radioactive material was inside. The HPGe detector measures the gamma rays emitted by radioactive material and displays it as a spectrum. The spectrum is used to identify this radioactive material by using appropriate analysis software and identifying the gamma ray peaks. A paint can container, DU-2A, was analyzed with PeakEasy 4.84 and FRAM 5.2. The FRAM report ismore » shown. The enrichment is 0.091% U235 and 99.907% U238. This material is depleted uranium. The measurement was performed in the near field, and to extract a mass a far field measurement will need to be taken.« less
Engel, Michael; Castrillon-Oberndorfer, Gregor; Hoffmann, Jürgen; Egermann, Marcus; Freudlsperger, Christian; Thiele, Oliver Christian
2012-09-01
This is a survey of the long-term result after various surgical treatments in a child with microcephalic osteodysplastic primordial dwarfism type II (MOPD II) and craniosynostosis. We report a 17-year-old patient with MOPD II but some unusual clinical signs including bilateral knee dislocation, a misplaced upper lobe bronchus, and hypoplasia of the anterior corpus callosum. Because of premature fusion of several cranial sutures, the child developed signs of increased intracranial pressure with somnolence and papilledema. Cranial vault remodeling with fronto-orbital advancement was performed twice at the age of 16 and 21 months to open the abnormally closed suture, increase the intracranial volume, and relieve the elevated intracranial pressure. Following this procedure, the child's neurologic situation recovered significantly. Surgical procedure of fronto-orbital advancement and the performed reoperation in our patient were safe with no major complications intraoperatively and postoperatively with good functional and satisfying aesthetic outcomes in the long-term follow-up, expressed by the patient, his parents, and the surgeons.
Ectocranial suture fusion in primates: pattern and phylogeny.
Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I
2014-03-01
Patterns of ectocranial suture fusion among Primates are subject to species-specific variation. In this study, we used Guttman Scaling to compare modal progression of ectocranial suture fusion among Hominidae (Homo, Pan, Gorilla, and Pongo), Hylobates, and Cercopithecidae (Macaca and Papio) groups. Our hypothesis is that suture fusion patterns should reflect their evolutionary relationship. For the lateral-anterior suture sites there appear to be three major patterns of fusion, one shared by Homo-Pan-Gorilla, anterior to posterior; one shared by Pongo and Hylobates, superior to inferior; and one shared by Cercopithecidae, posterior to anterior. For the vault suture pattern, the Hominidae groups reflect the known phylogeny. The data for Hylobates and Cercopithecidae groups is less clear. The vault suture site termination pattern of Papio is similar to that reported for Gorilla and Pongo. Thus, it may be that some suture sites are under larger genetic influence for patterns of fusion, while others are influenced by environmental/biomechanic influences. Copyright © 2013 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
1976-01-01
The applicability of energy storage devices to any energy system depends on the performance and cost characteristics of the larger basic system. A comparative assessment of energy storage alternatives for application to IUS which addresses the systems aspects of the overall installation is described. Factors considered include: (1) descriptions of the two no-storage IUS baselines utilized as yardsticks for comparison throughout the study; (2) discussions of the assessment criteria and the selection framework employed; (3) a summary of the rationale utilized in selecting water storage as the primary energy storage candidate for near term application to IUS; (4) discussion of the integration aspects of water storage systems; and (5) an assessment of IUS with water storage in alternative climates.
Geothermal materials development
NASA Astrophysics Data System (ADS)
Kukacka, L. E.
1991-12-01
Advances in the development of new materials, the commercial availabilities of which are essential for the attainment of Hydrothermal Category Level 1 and 2 Objectives, continue to be made in the Geothermal Materials Development Project. Many successes have already been accrued and the results used commercially. In FY-91, utility company sponsored 'full cost' recovery programs based upon materials technology developed in this project were initiated on topics such as condensing heat exchangers, high temperature composites for utility vaults used in district heating systems, and corrosion resistant coatings for use in oil-fired electric generating processes. In FY-91, the DOE/GD-sponsored R&D project was focused on reducing well drilling, fluid transport and energy conversion costs. Specific activities being performed included lightweight CO2-resistant well cements, chemical systems for lost circulation control, thermally conductive and scale resistant protective linear systems, corrosion mitigation in process components at The Geysers, and elastomer-metal bonding systems needed for use in high temperature well drilling and safety related applications.
2016-01-01
degradation of poly- and perfluoroalkyl compounds (PFCs), and potentially other water contaminants, without the need for repeated bioaugmentation with...active cultures or stimulation with nutrients. We designed a single-step method for encapsulating lignin peroxidases (LiP), manganese peroxidases (MnP
23. Photocopy of engineering drawing, April 10, 1958 (original drawing ...
23. Photocopy of engineering drawing, April 10, 1958 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering Vault). READINESS CREW BUILDING, UPPER FLOOR PLANS - Fairchild Air Force Base, Bomber Alert Facility, 803G South Taxi Way, Spokane, Spokane County, WA
22. Photocopy of engineering drawing, April 10, 1958 (original drawing ...
22. Photocopy of engineering drawing, April 10, 1958 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering Vault). READINESS CREW BUILDING, LOWER FLOOR PLANS - Fairchild Air Force Base, Bomber Alert Facility, 803G South Taxi Way, Spokane, Spokane County, WA
32. The 1704B Supervisor's Office and Laboratory building, which also ...
32. The 1704-B Supervisor's Office and Laboratory building, which also contained the classified materials vault. This type of wooden construction was typical in the 100-B Area. Viewed from the northwest in September 1944. P-4445 - B Reactor, Richland, Benton County, WA
CELLAR LOOKING NORTH (REAR SIDE OF BUILDING). AT LEFT ARE ...
CELLAR LOOKING NORTH (REAR SIDE OF BUILDING). AT LEFT ARE ORIGINAL BRICK ARCHES SUPPORTING BRICK PARTITIONS UPSTAIRS. AT CENTER IS BRICK PIER SUPPORTING MODERN SAFE. AT RIGHT IS BRICK PIER AND VAULT SUPPORTING ORIGINAL SAFE - Kid-Chandler House, 323 Walnut Street, Philadelphia, Philadelphia County, PA
Binghamton Burial Vault Co., 2017-06
EPA is providing notice of a proceeding to assess a Class I civil penalty for alleged violations of the Clean Water Act (Act). EPA is also providing notice of opportunity to comment on the proposed penalty assessment. Under 33 U.S.C. § 1319(g), EPA is auth
NASA Astrophysics Data System (ADS)
Lu, Meilian; Yang, Dong; Zhou, Xing
2013-03-01
Based on the analysis of the requirements of conversation history storage in CPM (Converged IP Messaging) system, a Multi-views storage model and access methods of conversation history are proposed. The storage model separates logical views from physical storage and divides the storage into system managed region and user managed region. It simultaneously supports conversation view, system pre-defined view and user-defined view of storage. The rationality and feasibility of multi-view presentation, the physical storage model and access methods are validated through the implemented prototype. It proves that, this proposal has good scalability, which will help to optimize the physical data storage structure and improve storage performance.
Storage systems for solar thermal power
NASA Technical Reports Server (NTRS)
Calogeras, J. E.; Gordon, L. H.
1978-01-01
The development status is reviewed of some thermal energy storage technologies specifically oriented towards providing diurnal heat storage for solar central power systems and solar total energy systems. These technologies include sensible heat storage in caverns and latent heat storage using both active and passive heat exchange processes. In addition, selected thermal storage concepts which appear promising to a variety of advanced solar thermal system applications are discussed.
NASA Astrophysics Data System (ADS)
Tesi, V.; Tucci, G.; Bonora, V.; Fiorini, L.; Conti, A.
2017-05-01
The deep fusion of natural and artificial elements typical of Italian Renaissance gardens is particularly evident in the park of Villa di Castello and in the Grotto of the Animals, also called Grotto of the Flood. The soil slope is the essential element of a huge underlying hydraulic machine and it is the result of extensive earthworks which led to the construction of the big retaining wall limiting the grotto and the adjacent fountains. Hence, this grotto represents only the visible part of a mechanism running all around it. It is formed by a single chamber vaulted and covered with sponge-like stones, as well as decorations made of pebbles and shells. The space is divided into three wings, with big marble basins at their end. Over them there are reliefs of animals made of different stones and marbles. Animals recur also in the compositions of fish and shellfish decorating the side basins and in the bronze birds currently kept in the Museo del Bargello. The name "Grotto of the Flood" comes from the water feature that characterised this place: visitors were surprised by tens of jets hidden among the stones in the vault and in the floor. To obtain this effect, the whole grotto is surrounded by multi-storey tunnels, hiding the hydraulic system and people activating the mechanisms. Research agreements were drawn up between the Special Superintendence for the Historical, Artistic and Ethnoanthropological Heritage, the Florence museums group and the GeCO Lab, for the realization of the survey presented in this paper. The task of the GeCO Lab was thus identifying the best solutions to check the spatial relations between the grotto and the area above, as well as the geometric and functional connections between the building and the ancient hydraulic system, composed by pipes and nozzles concealed between the stones. Besides, the overall survey was intended as a documentation of the on-going restoration work.
SU-E-T-495: Neutron Induced Electronics Failure Rate Analysis for a Single Room Proton Accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knutson, N; DeWees, T; Klein, E
2014-06-01
Purpose: To determine the failure rate as a function of neutron dose of the range modulator's servo motor controller system (SMCS) while shielded with Borated Polyethylene (BPE) and unshielded in a single room proton accelerator. Methods: Two experimental setups were constructed using two servo motor controllers and two motors. Each SMCS was then placed 30 cm from the end of the plugged proton accelerator applicator. The motor was then turned on and observed from outside of the vault while being irradiated to known neutron doses determined from bubble detector measurements. Anytime the motor deviated from the programmed motion a failuremore » was recorded along with the delivered dose. The experiment was repeated using 9 cm of BPE shielding surrounding the SMCS. Results: Ten SMCS failures were recorded in each experiment. The dose per monitor unit for the unshielded SMCS was 0.0211 mSv/MU and 0.0144 mSv/MU for the shielded SMCS. The mean dose to produce a failure for the unshielded SMCS was 63.5 ± 58.3 mSv versus 17.0 ±12.2 mSv for the shielded. The mean number of MUs between failures were 2297 ± 1891 MU for the unshielded SMCS and 2122 ± 1523 MU for the shielded. A Wilcoxon Signed Ranked test showed the dose between failures were significantly different (P value = 0.044) while the number of MUs between failures were not (P value = 1.000). Statistical analysis determined a SMCS neutron dose of 5.3 mSv produces a 5% chance of failure. Depending on the workload and location of the SMCS, this failure rate could impede clinical workflow. Conclusion: BPE shielding was shown to not reduce the average failure of the SMCS and relocation of the system outside of the accelerator vault was required to lower the failure rate enough to avoid impeding clinical work flow.« less
High Density Digital Data Storage System
NASA Technical Reports Server (NTRS)
Wright, Kenneth D., II; Gray, David L.; Rowland, Wayne D.
1991-01-01
The High Density Digital Data Storage System was designed to provide a cost effective means for storing real-time data from the field-deployable digital acoustic measurement system. However, the high density data storage system is a standalone system that could provide a storage solution for many other real time data acquisition applications. The storage system has inputs for up to 20 channels of 16-bit digital data. The high density tape recorders presently being used in the storage system are capable of storing over 5 gigabytes of data at overall transfer rates of 500 kilobytes per second. However, through the use of data compression techniques the system storage capacity and transfer rate can be doubled. Two tape recorders have been incorporated into the storage system to produce a backup tape of data in real-time. An analog output is provided for each data channel as a means of monitoring the data as it is being recorded.
Construction of the bridge in the cavern in the Vrata tunnel (Croatia)
NASA Astrophysics Data System (ADS)
Garasic, Mladen; Sasa Kovacevic, Meho; Juric-Kacunic, Danijela
2010-05-01
In the Dinaric karst system in Croatia some 11500 speleological objects have been explored so far, more than 1000 of which were discovered during construction works. Such speleological objects without natural entrance on the terrain surface (which are called "caverns") have been discovered on the construction sites of the highways. Over the past twenty years they have been systematically investigated and treated. A special kind of remediation was conducted in the cavern's large hall of the "Vrata" tunnel on the Zagreb - Rijeka highway. Due to size, shape, cavern's position and hydrogeological parameters (fissured and karstified aquifers) within the karst system it was necessary to design and construct a 58 m bridge over the cavern. In addition, the cavern's vault had to be reinforced and stabilized, as the overburden was very thin. The beam-and -stringer grid with special anchors was used. The cavern's rehabilitation in the "Vrata" tunnel was a unique undertaking, and the bridge (without piers) is the cavern's longest bridge in the world. A speleological object of large dimensions was discovered in the "Vrata"tunnel's right tube on the Rijeka-Zagreb highway. Speleological, geotechnical, engineering geological and hydrogeological investigation works were carried out for the purpose of preservation the speleological object (cavern). On the basis of classification results of rock masses and conducted numerical analyses the support system for the cavern's vault stabilization was selected. The support system's elements include the beam-and-stringer grid constructed on the terrain's surface above the cavern, tendons and geotechnical anchors. To ensure stability of the speleological object, and to conduct the backward numerical analyses the measurement of vertical deformations from the terrain's surface along the rock's mass by means of sliding micrometers was undertaken. Backward numerical analyses combined with geotechnical measurements enable safer and more rational approach to design and construction of underground structures. They contribute to the knowledge on rock mass performance and to determination of its physical and mechanical parameters connecting them with rock classification results. The analyses are a great help in verification or modification of elements' features of primary support system. Tunnel and bridge in tunnel "Vrata" were opened for traffic in November 2008. Keywords: speleology, cave, Dinaric karst, Croatia, tunnel, karst phenomena, geotechnical engineering.
Uterine injuries complicating hypertonic saline abortion
Willems, J. J.
1974-01-01
Two cases of uterine injury complicating midtrimester abortion induced by hypertonic saline are described, one with an extensive laceration of the cervix and the other with a rupture of the lower uterine segment extending into the vault of the vagina. The etiology, diagnosis and possible obstetric sequelae are discussed. PMID:4434292
6. Photocopy of Location, Site & Wall Sections drawing (from ...
6. Photocopy of Location, Site & Wall Sections drawing (from the Bonneville Power Administration Engineering Vault, Portland, Oregon, Drawing C13-J2-342-D1, Sheet 1, 13 March 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR
Qualification Testing of the SmartVault Household Goods Shipping Container
2011-01-06
base with 4-way forklift entry and molded high-density polyethylene (HDPE) ribbed walls and ( translucent ) lid which are held together with stainless...and four edge drops of the container onto a smooth concrete surface (Appendix 2, Figure 22). The container was visually inspected for damage
24. Photocopy of engineering drawing, August 17, 1965 (original drawing ...
24. Photocopy of engineering drawing, August 17, 1965 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering Vault). 2080 READINESS CREW, COVERED WALKWAYS, PLAN AND DETAILS - Fairchild Air Force Base, Bomber Alert Facility, 803G South Taxi Way, Spokane, Spokane County, WA
28. Photocopy of engineering drawing, May, 1941 (original drawing located ...
28. Photocopy of engineering drawing, May, 1941 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering vault). ENGINE TEST CELL BUILDING. AIR COOLED TEST STAND. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eibling, R.
Savannah River National Laboratory (SRNL) was asked to prepare saltstone from samples of Tank 50H obtained by SRNL on April 5, 2011 (Tank 50H sampling occurred on April 4, 2011) during 2QCY11 to determine the non-hazardous nature of the grout and for additional vault classification analyses. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&W TSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP) and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals - arsenic, barium,more » cadmium, chromium, mercury, lead, selenium and silver - analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge. Additional inorganic species determined by B&W TSG-RACL include aluminum, boron, chloride, cobalt, copper, fluoride, iron, lithium, manganese, molybdenum, nitrate/nitrite as Nitrogen, strontium, sulfate, uranium, and zinc and the following radionuclides: gross alpha, gross beta/gamma, 3H, 60Co, 90Sr, 99Tc, 106Ru, 106Rh, 125Sb, 137Cs, 137mBa, 154Eu, 238Pu, 239/240Pu, 241Pu, 241Am, 242Cm, and 243/244Cm. B&W TSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the VOCs benzene, toluene, and 1-butanol. GEL also determines phenol (total) and the following radionuclides: 147Pm, 226Ra and 228Ra. Preparation of the 2QCY11 saltstone samples for the quarterly analysis and for vault classification purposes and the subsequent TCLP analyses of these samples showed that: (1) The saltstone waste form disposed of in the Saltstone Disposal Facility in 2QCY11 was not characteristically hazardous for toxicity. (2) The concentrations of the eight RCRA metals and UHCs identified as possible in the saltstone waste form were present at levels below the UTS. (3) Most of the inorganic species measured in the leachate do not exceed the MCL, SMCL or TW limits. (4) The inorganic waste species that exceeded the MCL by more than a factor of 10 were nitrate, nitrite and the sum of nitrate and nitrite. (5) Analyses met all quality assurance specifications of US EPA SW-846. (6) The organic species (benzene, toluene, 1-butanol, phenol) were either not detected or were less than reportable for the vault classification samples. (7) The gross alpha and radium isotopes could not be determined to the MCL because of the elevated background which raised the detection limits. (8) Most of the beta/gamma activity was from 137Cs and its daughter 137mBa. (9) The concentration of 137Cs and 90Sr were present in the leachate at concentrations 1/40th and 1/8th respectively than in the 2003 vault classification samples. The saltstone waste form placed in the Saltstone Disposal Facility in 2QCY11 met the SCHWMR R.61-79.261.24(b) RCRA metals requirements for a nonhazardous waste form. The TCLP leachate concentrations for nitrate, nitrite and the sum of nitrate and nitrite were greater than 10x the MCLs in SCDHEC Regulations R.61-107.19, Part I A, which confirms the Saltstone Disposal Facility classification as a Class 3 Landfill. The saltstone waste form placed in the Saltstone Disposal Facility in 2QCY11 met the R.61-79.268.48(a) non wastewater treatment standards.« less
Storage system software solutions for high-end user needs
NASA Technical Reports Server (NTRS)
Hogan, Carole B.
1992-01-01
Today's high-end storage user is one that requires rapid access to a reliable terabyte-capacity storage system running in a distributed environment. This paper discusses conventional storage system software and concludes that this software, designed for other purposes, cannot meet high-end storage requirements. The paper also reviews the philosophy and design of evolving storage system software. It concludes that this new software, designed with high-end requirements in mind, provides the potential for solving not only the storage needs of today but those of the foreseeable future as well.
Uncoupling File System Components for Bridging Legacy and Modern Storage Architectures
NASA Astrophysics Data System (ADS)
Golpayegani, N.; Halem, M.; Tilmes, C.; Prathapan, S.; Earp, D. N.; Ashkar, J. S.
2016-12-01
Long running Earth Science projects can span decades of architectural changes in both processing and storage environments. As storage architecture designs change over decades such projects need to adjust their tools, systems, and expertise to properly integrate such new technologies with their legacy systems. Traditional file systems lack the necessary support to accommodate such hybrid storage infrastructure resulting in more complex tool development to encompass all possible storage architectures used for the project. The MODIS Adaptive Processing System (MODAPS) and the Level 1 and Atmospheres Archive and Distribution System (LAADS) is an example of a project spanning several decades which has evolved into a hybrid storage architecture. MODAPS/LAADS has developed the Lightweight Virtual File System (LVFS) which ensures a seamless integration of all the different storage architectures, including standard block based POSIX compliant storage disks, to object based architectures such as the S3 compliant HGST Active Archive System, and the Seagate Kinetic disks utilizing the Kinetic Protocol. With LVFS, all analysis and processing tools used for the project continue to function unmodified regardless of the underlying storage architecture enabling MODAPS/LAADS to easily integrate any new storage architecture without the costly need to modify existing tools to utilize such new systems. Most file systems are designed as a single application responsible for using metadata to organizing the data into a tree, determine the location for data storage, and a method of data retrieval. We will show how LVFS' unique approach of treating these components in a loosely coupled fashion enables it to merge different storage architectures into a single uniform storage system which bridges the underlying hybrid architecture.
NASA Astrophysics Data System (ADS)
McKenzie, A. W.
Cost and performance of various thermal storage concepts in a liquid metal receiver solar thermal power system application have been evaluated. The objectives of this study are to provide consistently calculated cost and performance data for thermal storage concepts integrated into solar thermal systems. Five alternative storage concepts are evaluated for a 100-MW(e) liquid metal-cooled receiver solar thermal power system for 1, 6, and 15 hours of storage: sodium 2-tank (reference system), molten draw salt 2-tank, sand moving bed, air/rock, and latent heat (phase change) with tube-intensive heat exchange (HX). The results indicate that the all sodium 2-tank thermal storage concept is not cost-effective for storage in excess of 3 or 4 hours; the molten draw salt 2-tank storage concept provides significant cost savings over the reference sodium 2-tank concept; and the air/rock storage concept with pressurized sodium buffer tanks provides the lowest evaluated cost of all storage concepts considered above 6 hours of storage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Ownership of an underground storage tank or underground storage tank system or facility or property on which an underground storage tank or underground storage tank system is located. 280.220 Section 280.220 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID...
Subcontracted activities related to TES for building heating and cooling
NASA Technical Reports Server (NTRS)
Martin, J.
1980-01-01
The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.
Carbon Dioxide Emissions Effects of Grid-Scale Electricity Storage in a Decarbonizing Power System
Craig, Michael T.; Jaramillo, Paulina; Hodge, Bri-Mathias
2018-01-03
While grid-scale electricity storage (hereafter 'storage') could be crucial for deeply decarbonizing the electric power system, it would increase carbon dioxide (CO 2) emissions in current systems across the United States. To better understand how storage transitions from increasing to decreasing system CO 2 emissions, we quantify the effect of storage on operational CO 2 emissions as a power system decarbonizes under a moderate and strong CO 2 emission reduction target through 2045. Under each target, we compare the effect of storage on CO 2 emissions when storage participates in only energy, only reserve, and energy and reserve markets. Wemore » conduct our study in the Electricity Reliability Council of Texas (ERCOT) system and use a capacity expansion model to forecast generator fleet changes and a unit commitment and economic dispatch model to quantify system CO 2 emissions with and without storage. We find that storage would increase CO 2 emissions in the current ERCOT system, but would decrease CO 2 emissions in 2025 through 2045 under both decarbonization targets. Storage reduces CO 2 emissions primarily by enabling gas-fired generation to displace coal-fired generation, but also by reducing wind and solar curtailment. We further find that the market in which storage participates drives large differences in the magnitude, but not the direction, of the effect of storage on CO 2 emissions.« less
Carbon Dioxide Emissions Effects of Grid-Scale Electricity Storage in a Decarbonizing Power System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craig, Michael T.; Jaramillo, Paulina; Hodge, Bri-Mathias
While grid-scale electricity storage (hereafter 'storage') could be crucial for deeply decarbonizing the electric power system, it would increase carbon dioxide (CO 2) emissions in current systems across the United States. To better understand how storage transitions from increasing to decreasing system CO 2 emissions, we quantify the effect of storage on operational CO 2 emissions as a power system decarbonizes under a moderate and strong CO 2 emission reduction target through 2045. Under each target, we compare the effect of storage on CO 2 emissions when storage participates in only energy, only reserve, and energy and reserve markets. Wemore » conduct our study in the Electricity Reliability Council of Texas (ERCOT) system and use a capacity expansion model to forecast generator fleet changes and a unit commitment and economic dispatch model to quantify system CO 2 emissions with and without storage. We find that storage would increase CO 2 emissions in the current ERCOT system, but would decrease CO 2 emissions in 2025 through 2045 under both decarbonization targets. Storage reduces CO 2 emissions primarily by enabling gas-fired generation to displace coal-fired generation, but also by reducing wind and solar curtailment. We further find that the market in which storage participates drives large differences in the magnitude, but not the direction, of the effect of storage on CO 2 emissions.« less
Terrestrial Energy Storage SPS Systems
NASA Technical Reports Server (NTRS)
Brandhorst, Henry W., Jr.
1998-01-01
Terrestrial energy storage systems for the SSP system were evaluated that could maintain the 1.2 GW power level during periods of brief outages from the solar powered satellite (SPS). Short-term outages of ten minutes and long-term outages up to four hours have been identified as "typical" cases where the ground-based energy storage system would be required to supply power to the grid. These brief interruptions in transmission could result from performing maintenance on the solar power satellite or from safety considerations necessitating the power beam be turned off. For example, one situation would be to allow for the safe passage of airplanes through the space occupied by the beam. Under these conditions, the energy storage system needs to be capable of storing 200 MW-hrs and 4.8 GW-hrs, respectively. The types of energy storage systems to be considered include compressed air energy storage, inertial energy storage, electrochemical energy storage, superconducting magnetic energy storage, and pumped hydro energy storage. For each of these technologies, the state-of-the-art in terms of energy and power densities were identified as well as the potential for scaling to the size systems required by the SSP system. Other issues addressed included the performance, life expectancy, cost, and necessary infrastructure and site locations for the various storage technologies.
Brooks, Kriston P; Holladay, Jamelyn D; Simmons, Kevin L; Herling, Darrell R
2014-11-18
An on-board hydride storage system and process are described. The system includes a slurry storage system that includes a slurry reactor and a variable concentration slurry. In one preferred configuration, the storage system stores a slurry containing a hydride storage material in a carrier fluid at a first concentration of hydride solids. The slurry reactor receives the slurry containing a second concentration of the hydride storage material and releases hydrogen as a fuel to hydrogen-power devices and vehicles.
Battery management system with distributed wireless sensors
Farmer, Joseph C.; Bandhauer, Todd M.
2016-02-23
A system for monitoring parameters of an energy storage system having a multiplicity of individual energy storage cells. A radio frequency identification and sensor unit is connected to each of the individual energy storage cells. The radio frequency identification and sensor unit operates to sense the parameter of each individual energy storage cell and provides radio frequency transmission of the parameters of each individual energy storage cell. A management system monitors the radio frequency transmissions from the radio frequency identification and sensor units for monitoring the parameters of the energy storage system.
Cerebrospinal Fluid Mechanics and Its Coupling to Cerebrovascular Dynamics
NASA Astrophysics Data System (ADS)
Linninger, Andreas A.; Tangen, Kevin; Hsu, Chih-Yang; Frim, David
2016-01-01
Cerebrospinal fluid (CSF) is not stagnant but displays fascinating oscillatory flow patterns inside the ventricular system and reversing fluid exchange between the cranial vault and spinal compartment. This review provides an overview of the current knowledge of pulsatile CSF motion. Observations contradicting classical views about its bulk production and clearance are highlighted. A clinical account of diseases of abnormal CSF flow dynamics, including hydrocephalus, syringomyelia, Chiari malformation type 1, and pseudotumor cerebri, is also given. We survey medical imaging modalities used to observe intracranial dynamics in vivo. Additionally, we assess the state of the art in predictive models of CSF dynamics. The discussion addresses open questions regarding CSF dynamics as they relate to the understanding and management of diseases.
NASA Technical Reports Server (NTRS)
Kobler, Benjamin (Editor); Hariharan, P. C. (Editor)
2002-01-01
This document contains copies of those technical papers received in time for publication prior to the Tenth Goddard Conference on Mass Storage Systems and Technologies which is being held in cooperation with the Nineteenth IEEE Symposium on Mass Storage Systems at the University of Maryland University College Inn and Conference Center April 15-18, 2002. As one of an ongoing series, this Conference continues to provide a forum for discussion of issues relevant to the ingest, storage, and management of large volumes of data. The Conference encourages all interested organizations to discuss long-term mass storage requirements and experiences in fielding solutions. Emphasis is on current and future practical solutions addressing issues in data management, storage systems and media, data acquisition, long-term retention of data, and data distribution. This year's discussion topics include architecture, future of current technology, storage networking with emphasis on IP storage, performance, standards, site reports, and vendor solutions. Tutorials will be available on perpendicular magnetic recording, object based storage, storage virtualization and IP storage.
Energy Storage Laboratory | Energy Systems Integration Facility | NREL
technologies. Key Infrastructure Energy storage system inverter, energy storage system simulators, research Plug-In Vehicles/Mobile Storage The plug-in vehicles/mobile storage hub includes connections for small integration. Key Infrastructure Ample house power, REDB access, charging stations, easy vehicle parking access
He, Qing; Hao, Yinping; Liu, Hui; Liu, Wenyi
2018-01-01
Super-critical carbon dioxide energy-storage (SC-CCES) technology is a new type of gas energy-storage technology. This paper used orthogonal method and variance analysis to make significant analysis on the factors which would affect the thermodynamics characteristics of the SC-CCES system and obtained the significant factors and interactions in the energy-storage process, the energy-release process and the whole energy-storage system. Results have shown that the interactions in the components have little influence on the energy-storage process, the energy-release process and the whole energy-storage process of the SC-CCES system, the significant factors are mainly on the characteristics of the system component itself, which will provide reference for the optimization of the thermal properties of the energy-storage system.
He, Qing; Liu, Hui; Liu, Wenyi
2018-01-01
Super-critical carbon dioxide energy-storage (SC-CCES) technology is a new type of gas energy-storage technology. This paper used orthogonal method and variance analysis to make significant analysis on the factors which would affect the thermodynamics characteristics of the SC-CCES system and obtained the significant factors and interactions in the energy-storage process, the energy-release process and the whole energy-storage system. Results have shown that the interactions in the components have little influence on the energy-storage process, the energy-release process and the whole energy-storage process of the SC-CCES system, the significant factors are mainly on the characteristics of the system component itself, which will provide reference for the optimization of the thermal properties of the energy-storage system. PMID:29634742
Collapse displacements for a mechanism of spreading-induced supports in a masonry arch
NASA Astrophysics Data System (ADS)
Coccia, Simona; Di Carlo, Fabio; Rinaldi, Zila
2015-09-01
Masonry arch systems and vaulted structures constitute a structural typology widely spread in the historical building heritage. Small displacements of the supports, due to different causes, among which subsidence of foundation systems or movements of underlying structures can lead the masonry arch to a condition of collapse because of gradual change in its geometry. This paper presents a tool, based on a kinematic approach, for the computation of the magnitude of the displacements that cause the collapse of circular arches subject to dead loads, and allows the evaluation of the related thrust value. A parametric study has been carried out in order to develop a deeper understanding of the influence of the involved parameters. In addition, analytic formulations of the maximum allowed displacement and the associated thrust are proposed. Finally, a case study related to the behavior of a masonry arch on spreading-induced abutments is undertaken and discussed.
Self-testing security sensor for monitoring closure of vault doors and the like
Cawthorne, Duane C.
1997-05-27
A self-testing device is provided for a monitoring system for monitoring whether a closure member such as a door or window is closed. The monitoring system includes a switch unit mounted on the frame of the closure member being monitored and including magnetically biased switches connected in one or more electrical monitoring circuits, and a door magnet unit mounted on the closure member being monitored. The door magnet includes one or more permanent magnets that produce a magnetic field which, when the closure member is closed, cause said switches to assume a first state. When the closure member is opened, the switches switch to a second, alarm state. The self-testing device is electrically controllable from a remote location and produces a canceling or diverting magnetic field which simulates the effect of movement of the closure member from the closed position thereof without any actual movement of the member.
Self-testing security sensor for monitoring closure of vault doors and the like
Cawthorne, D.C.
1997-05-27
A self-testing device is provided for a monitoring system for monitoring whether a closure member such as a door or window is closed. The monitoring system includes a switch unit mounted on the frame of the closure member being monitored and including magnetically biased switches connected in one or more electrical monitoring circuits, and a door magnet unit mounted on the closure member being monitored. The door magnet includes one or more permanent magnets that produce a magnetic field which, when the closure member is closed, cause said switches to assume a first state. When the closure member is opened, the switches switch to a second, alarm state. The self-testing device is electrically controllable from a remote location and produces a canceling or diverting magnetic field which simulates the effect of movement of the closure member from the closed position thereof without any actual movement of the member. 5 figs.
NREL Tests Energy Storage System to Fill Renewable Gaps | News | NREL
Tests Energy Storage System to Fill Renewable Gaps NREL Tests Energy Storage System to Fill -megawatt energy storage system from Renewable Energy Systems (RES) Americas will assist research that aims to optimize the grid for wind and solar plants. The system arrived at NREL's National Wind Technology
The Design of Distributed Micro Grid Energy Storage System
NASA Astrophysics Data System (ADS)
Liang, Ya-feng; Wang, Yan-ping
2018-03-01
Distributed micro-grid runs in island mode, the energy storage system is the core to maintain the micro-grid stable operation. For the problems that it is poor to adjust at work and easy to cause the volatility of micro-grid caused by the existing energy storage structure of fixed connection. In this paper, an array type energy storage structure is proposed, and the array type energy storage system structure and working principle are analyzed. Finally, the array type energy storage structure model is established based on MATLAB, the simulation results show that the array type energy storage system has great flexibility, which can maximize the utilization of energy storage system, guarantee the reliable operation of distributed micro-grid and achieve the function of peak clipping and valley filling.
Telemetry data storage systems technology for the Space Station Freedom era
NASA Technical Reports Server (NTRS)
Dalton, John T.
1989-01-01
This paper examines the requirements and functions of the telemetry-data recording and storage systems, and the data-storage-system technology projected for the Space Station, with particular attention given to the Space Optical Disk Recorder, an on-board storage subsystem based on 160 gigabit erasable optical disk units each capable of operating at 300 M bits per second. Consideration is also given to storage systems for ground transport recording, which include systems for data capture, buffering, processing, and delivery on the ground. These can be categorized as the first in-first out storage, the fast random-access storage, and the slow access with staging. Based on projected mission manifests and data rates, the worst case requirements were developed for these three storage architecture functions. The results of the analysis are presented.
Conceptual design of thermal energy storage systems for near-term electric utility applications
NASA Technical Reports Server (NTRS)
Hall, E. W.
1980-01-01
Promising thermal energy storage systems for midterm applications in conventional electric utilities for peaking power generation are evaluated. Conceptual designs of selected thermal energy storage systems integrated with conventional utilities are considered including characteristics of alternate systems for peaking power generation, viz gas turbines and coal fired cycling plants. Competitive benefit analysis of thermal energy storage systems with alternate systems for peaking power generation and recommendations for development and field test of thermal energy storage with a conventional utility are included. Results indicate that thermal energy storage is only marginally competitive with coal fired cycling power plants and gas turbines for peaking power generation.
49 CFR 173.311 - Metal hydride storage systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 2 2013-10-01 2013-10-01 false Metal hydride storage systems. 173.311 Section 173... REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.311 Metal hydride storage systems. The following packing instruction is applicable to transportable UN Metal hydride storage systems...
49 CFR 173.311 - Metal hydride storage systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 2 2011-10-01 2011-10-01 false Metal hydride storage systems. 173.311 Section 173... REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.311 Metal hydride storage systems. The following packing instruction is applicable to transportable UN Metal hydride storage systems...
49 CFR 173.311 - Metal hydride storage systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 2 2014-10-01 2014-10-01 false Metal hydride storage systems. 173.311 Section 173... REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.311 Metal hydride storage systems. The following packing instruction is applicable to transportable UN Metal hydride storage systems...
What do cranial bones of LB1 tell us about Homo floresiensis?
Balzeau, Antoine; Charlier, Philippe
2016-04-01
Cranial vault thickness (CVT) of Liang Bua 1, the specimen that is proposed to be the holotype of Homo floresiensis, has not yet been described in detail and compared with samples of fossil hominins, anatomically modern humans or microcephalic skulls. In addition, a complete description from a forensic and pathological point of view has not yet been carried out. It is important to evaluate scientifically if features related to CVT bring new information concerning the possible pathological status of LB1, and if it helps to recognize affinities with any hominin species and particularly if the specimen could belong to the species Homo sapiens. Medical examination of the skull based on a micro-CT examination clearly brings to light the presence of a sincipital T (a non-metrical variant of normal anatomy), a scar from an old frontal trauma without any evident functional consequence, and a severe bilateral hyperostosis frontalis interna that may have modified the anterior morphology of the endocranium of LB1. We also show that LB1 displays characteristics, related to the distribution of bone thickness and arrangements of cranial structures, that are plesiomorphic traits for hominins, at least for Homo erectus s.l. relative to Homo neanderthalensis and H. sapiens. All the microcephalic skulls analyzed here share the derived condition of anatomically modern H. sapiens. Cranial vault thickness does not help to clarify the definition of the species H. floresiensis but it also does not support an attribution of LB1 to H. sapiens. We conclude that there is no support for the attribution of LB1 to H. sapiens as there is no evidence of systemic pathology and because it does not have any of the apomorphic traits of our species. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Soltis, Steven R.; Ruwart, Thomas M.; OKeefe, Matthew T.
1996-01-01
The global file system (GFS) is a prototype design for a distributed file system in which cluster nodes physically share storage devices connected via a network-like fiber channel. Networks and network-attached storage devices have advanced to a level of performance and extensibility so that the previous disadvantages of shared disk architectures are no longer valid. This shared storage architecture attempts to exploit the sophistication of storage device technologies whereas a server architecture diminishes a device's role to that of a simple component. GFS distributes the file system responsibilities across processing nodes, storage across the devices, and file system resources across the entire storage pool. GFS caches data on the storage devices instead of the main memories of the machines. Consistency is established by using a locking mechanism maintained by the storage devices to facilitate atomic read-modify-write operations. The locking mechanism is being prototyped in the Silicon Graphics IRIX operating system and is accessed using standard Unix commands and modules.
Online mass storage system detailed requirements document
NASA Technical Reports Server (NTRS)
1976-01-01
The requirements for an online high density magnetic tape data storage system that can be implemented in a multipurpose, multihost environment is set forth. The objective of the mass storage system is to provide a facility for the compact storage of large quantities of data and to make this data accessible to computer systems with minimum operator handling. The results of a market survey and analysis of candidate vendor who presently market high density tape data storage systems are included.
Chemical hydrogen storage material property guidelines for automotive applications
NASA Astrophysics Data System (ADS)
Semelsberger, Troy A.; Brooks, Kriston P.
2015-04-01
Chemical hydrogen storage is the sought after hydrogen storage media for automotive applications because of the expected low pressure operation (<20 atm), moderate temperature operation (<200 °C), system gravimetric capacities (>0.05 kg H2/kgsystem), and system volumetric capacities (>0.05 kg H2/Lsystem). Currently, the primary shortcomings of chemical hydrogen storage are regeneration efficiency, fuel cost and fuel phase (i.e., solid or slurry phase). Understanding the required material properties to meet the DOE Technical Targets for Onboard Hydrogen Storage Systems is a critical knowledge gap in the hydrogen storage research community. This study presents a set of fluid-phase chemical hydrogen storage material property guidelines for automotive applications meeting the 2017 DOE technical targets. Viable material properties were determined using a boiler-plate automotive system design. The fluid-phase chemical hydrogen storage media considered in this study were neat liquids, solutions, and non-settling homogeneous slurries. Material properties examined include kinetics, heats of reaction, fuel-cell impurities, gravimetric and volumetric hydrogen storage capacities, and regeneration efficiency. The material properties, although not exhaustive, are an essential first step in identifying viable chemical hydrogen storage material properties-and most important, their implications on system mass, system volume and system performance.
Application of electrochemical energy storage in solar thermal electric generation systems
NASA Technical Reports Server (NTRS)
Das, R.; Krauthamer, S.; Frank, H.
1982-01-01
This paper assesses the status, cost, and performance of existing electrochemical energy storage systems, and projects the cost, performance, and availability of advanced storage systems for application in terrestrial solar thermal electric generation. A 10 MWe solar plant with five hours of storage is considered and the cost of delivered energy is computed for sixteen different storage systems. The results indicate that the five most attractive electrochemical storage systems use the following battery types: zinc-bromine (Exxon), iron-chromium redox (NASA/Lewis Research Center, LeRC), sodium-sulfur (Ford), sodium-sulfur (Dow), and zinc-chlorine (Energy Development Associates, EDA).
Capacity value of energy storage considering control strategies.
Shi, Nian; Luo, Yi
2017-01-01
In power systems, energy storage effectively improves the reliability of the system and smooths out the fluctuations of intermittent energy. However, the installed capacity value of energy storage cannot effectively measure the contribution of energy storage to the generator adequacy of power systems. To achieve a variety of purposes, several control strategies may be utilized in energy storage systems. The purpose of this paper is to study the influence of different energy storage control strategies on the generation adequacy. This paper presents the capacity value of energy storage to quantitatively estimate the contribution of energy storage on the generation adequacy. Four different control strategies are considered in the experimental method to study the capacity value of energy storage. Finally, the analysis of the influence factors on the capacity value under different control strategies is given.
A new seamless, smooth, interior, absorptive finishing system
NASA Astrophysics Data System (ADS)
D'Antonio, Peter
2003-10-01
Government architecture typically employs classic forms of vaults, domes and other focusing or reflective shapes, usually created with hard materials like concrete and plaster. The use of conventional porous absorption is typically rejected as an acoustical surface material for aesthetic reasons. Hence, many of these new and existing facilities have compromised speech intelligibility and music quality. Acousticians have sought a field-applied, absorptive finishing system that resembles a smooth plaster or painted drywall surface, since the dawn of architectural acoustics. Some success has been achieved using sprayed cellulose or cementitious materials, but surface smoothness has been a challenge. A new approach utilizing a thin microporous layer of mineral particles applied over a mineral wool panel will be described. This material can be applied to almost any shape surface, internally pigmented to match almost any color and renovated. Because of these unique characteristics the new seamless, absorptive, finishing system is being specified for many new and renovated spaces. Application examples will be presented.
Faxing Structures to the Moon: Freeform Additive Construction System (FACS)
NASA Technical Reports Server (NTRS)
Howe, A. Scott; Wilcox, Brian; McQuin, Christopher; Townsend, Julie; Rieber, Richard; Barmatz, Martin; Leichty, John
2013-01-01
Using the highly articulated All-Terrain Hex-Limbed Extra-Terrestrial Explorer (ATHLETE) robotic mobility system as a precision positioning tool, a variety of print head technologies can be used to 3D print large-scale in-situ structures on planetary surfaces such as the moon or Mars. In effect, in the same way CAD models can be printed in a 3D printer, large-scale structures such as walls, vaults, domes, berms, paving, trench walls, and other insitu derived elements can be FAXed to the planetary surface and built in advance of the arrival of crews, supplementing equipment and materials brought from earth. This paper discusses the ATHLETE system as a mobility / positioning platform, and presents several options for large-scale additive print head technologies, including tunable microwave "sinterator" approaches and in-situ concrete deposition. The paper also discusses potential applications, such as sintered-in-place habitat shells, radiation shielding, road paving, modular bricks, and prefabricated construction components.
Carbon dioxide emissions effects of grid-scale electricity storage in a decarbonizing power system
NASA Astrophysics Data System (ADS)
Craig, Michael T.; Jaramillo, Paulina; Hodge, Bri-Mathias
2018-01-01
While grid-scale electricity storage (hereafter ‘storage’) could be crucial for deeply decarbonizing the electric power system, it would increase carbon dioxide (CO2) emissions in current systems across the United States. To better understand how storage transitions from increasing to decreasing system CO2 emissions, we quantify the effect of storage on operational CO2 emissions as a power system decarbonizes under a moderate and strong CO2 emission reduction target through 2045. Under each target, we compare the effect of storage on CO2 emissions when storage participates in only energy, only reserve, and energy and reserve markets. We conduct our study in the Electricity Reliability Council of Texas (ERCOT) system and use a capacity expansion model to forecast generator fleet changes and a unit commitment and economic dispatch model to quantify system CO2 emissions with and without storage. We find that storage would increase CO2 emissions in the current ERCOT system, but would decrease CO2 emissions in 2025 through 2045 under both decarbonization targets. Storage reduces CO2 emissions primarily by enabling gas-fired generation to displace coal-fired generation, but also by reducing wind and solar curtailment. We further find that the market in which storage participates drives large differences in the magnitude, but not the direction, of the effect of storage on CO2 emissions.
NASA Astrophysics Data System (ADS)
Seitz, M.; Hübner, S.; Johnson, M.
2016-05-01
Direct steam generation enables the implementation of a higher steam temperature for parabolic trough concentrated solar power plants. This leads to much better cycle efficiencies and lower electricity generating costs. For a flexible and more economic operation of such a power plant, it is necessary to develop thermal energy storage systems for the extension of the production time of the power plant. In the case of steam as the heat transfer fluid, it is important to use a storage material that uses latent heat for the storage process. This leads to a minimum of exergy losses during the storage process. In the case of a concentrating solar power plant, superheated steam is needed during the discharging process. This steam cannot be superheated by the latent heat storage system. Therefore, a sensible molten salt storage system is used for this task. In contrast to the state-of-the-art thermal energy storages within the concentrating solar power area of application, a storage system for a direct steam generation plant consists of a latent and a sensible storage part. Thus far, no partial load behaviors of sensible and latent heat storage systems have been analyzed in detail. In this work, an optimized fin structure was developed in order to minimize the costs of the latent heat storage. A complete system simulation of the power plant process, including the solar field, power block and sensible and latent heat energy storage calculates the interaction between the solar field, the power block and the thermal energy storage system.
NASA Technical Reports Server (NTRS)
Kobler, Ben (Editor); Hariharan, P. C. (Editor); Blasso, L. G. (Editor)
1992-01-01
This report contains copies of nearly all of the technical papers and viewgraphs presented at the NSSDC Conference on Mass Storage Systems and Technologies for Space and Earth Science Application. This conference served as a broad forum for the discussion of a number of important issues in the field of mass storage systems. Topics include the following: magnetic disk and tape technologies; optical disk and tape; software storage and file management systems; and experiences with the use of a large, distributed storage system. The technical presentations describe, among other things, integrated mass storage systems that are expected to be available commercially. Also included is a series of presentations from Federal Government organizations and research institutions covering their mass storage requirements for the 1990's.
NASA Technical Reports Server (NTRS)
Kobler, Ben (Editor); Hariharan, P. C. (Editor); Blasso, L. G. (Editor)
1992-01-01
This report contains copies of nearly all of the technical papers and viewgraphs presented at the National Space Science Data Center (NSSDC) Conference on Mass Storage Systems and Technologies for Space and Earth Science Applications. This conference served as a broad forum for the discussion of a number of important issues in the field of mass storage systems. Topics include magnetic disk and tape technologies, optical disk and tape, software storage and file management systems, and experiences with the use of a large, distributed storage system. The technical presentations describe, among other things, integrated mass storage systems that are expected to be available commercially. Also included is a series of presentations from Federal Government organizations and research institutions covering their mass storage requirements for the 1990s.
Comparison of advanced thermal and electrical storage for parabolic dish solar thermal power systems
NASA Astrophysics Data System (ADS)
Fujita, T.; Birur, G. C.; Schredder, J. M.; Bowyer, J. M.; Awaya, H. I.
Parabolic dish solar concentrator cluster concepts are explored, with attention given to thermal storage systems coupled to Stirling and Brayton cycle power conversion devices. Sensible heat storage involving molten salt (NaOH), liquid sodium, and solid cordierite bricks are considered for 1500 F thermal storage systems. Latent heat storage with NaF-MgF2 phase change materials are explored in terms of passive, active, and direct contact designs. Comparisons are made of the effectiveness of thermal storage relative to redox, Na-S, Zn-Cl, and Zn-Br battery storage systems. Molten lead trickling down through a phase change eutectic, the NaF-MgF2, formed the direct contact system. Heat transport in all systems is effected through Inconel pipes. Using a cost goal of 120-150 mills/kWh as the controlling parameter, sensible heat systems with molten salts transport with either Stirling or Brayton engines, or latent heat systems with Stirling engines, and latent heat-Brayton engine with direct contact were favored in the analyses. Battery storage systems, however, offered the most flexibility of applications.
Comparison of advanced thermal and electrical storage for parabolic dish solar thermal power systems
NASA Technical Reports Server (NTRS)
Fujita, T.; Birur, G. C.; Schredder, J. M.; Bowyer, J. M.; Awaya, H. I.
1982-01-01
Parabolic dish solar concentrator cluster concepts are explored, with attention given to thermal storage systems coupled to Stirling and Brayton cycle power conversion devices. Sensible heat storage involving molten salt (NaOH), liquid sodium, and solid cordierite bricks are considered for 1500 F thermal storage systems. Latent heat storage with NaF-MgF2 phase change materials are explored in terms of passive, active, and direct contact designs. Comparisons are made of the effectiveness of thermal storage relative to redox, Na-S, Zn-Cl, and Zn-Br battery storage systems. Molten lead trickling down through a phase change eutectic, the NaF-MgF2, formed the direct contact system. Heat transport in all systems is effected through Inconel pipes. Using a cost goal of 120-150 mills/kWh as the controlling parameter, sensible heat systems with molten salts transport with either Stirling or Brayton engines, or latent heat systems with Stirling engines, and latent heat-Brayton engine with direct contact were favored in the analyses. Battery storage systems, however, offered the most flexibility of applications.
10. Photocopy of Miscellaneous Details drawing showing door, window, louvre, ...
10. Photocopy of Miscellaneous Details drawing showing door, window, louvre, stairway, roof and other detailing (from the BPA Engineering Vault, Drawing C13-J2-342-D1, Sheet 4, 13 March 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR
12 CFR 3.32 - General risk weights.
Code of Federal Regulations, 2014 CFR
2014-01-01
... a percent of the appraised value of the property; (iii) Is not 90 days or more past due or carried... of the national bank or Federal savings association or in transit; to gold bullion held in the... vaults on an allocated basis, to the extent the gold bullion assets are offset by gold bullion...