Convolutional Neural Network-Based Finger-Vein Recognition Using NIR Image Sensors
Hong, Hyung Gil; Lee, Min Beom; Park, Kang Ryoung
2017-01-01
Conventional finger-vein recognition systems perform recognition based on the finger-vein lines extracted from the input images or image enhancement, and texture feature extraction from the finger-vein images. In these cases, however, the inaccurate detection of finger-vein lines lowers the recognition accuracy. In the case of texture feature extraction, the developer must experimentally decide on a form of the optimal filter for extraction considering the characteristics of the image database. To address this problem, this research proposes a finger-vein recognition method that is robust to various database types and environmental changes based on the convolutional neural network (CNN). In the experiments using the two finger-vein databases constructed in this research and the SDUMLA-HMT finger-vein database, which is an open database, the method proposed in this research showed a better performance compared to the conventional methods. PMID:28587269
Convolutional Neural Network-Based Finger-Vein Recognition Using NIR Image Sensors.
Hong, Hyung Gil; Lee, Min Beom; Park, Kang Ryoung
2017-06-06
Conventional finger-vein recognition systems perform recognition based on the finger-vein lines extracted from the input images or image enhancement, and texture feature extraction from the finger-vein images. In these cases, however, the inaccurate detection of finger-vein lines lowers the recognition accuracy. In the case of texture feature extraction, the developer must experimentally decide on a form of the optimal filter for extraction considering the characteristics of the image database. To address this problem, this research proposes a finger-vein recognition method that is robust to various database types and environmental changes based on the convolutional neural network (CNN). In the experiments using the two finger-vein databases constructed in this research and the SDUMLA-HMT finger-vein database, which is an open database, the method proposed in this research showed a better performance compared to the conventional methods.
Finger vein verification system based on sparse representation.
Xin, Yang; Liu, Zhi; Zhang, Haixia; Zhang, Hong
2012-09-01
Finger vein verification is a promising biometric pattern for personal identification in terms of security and convenience. The recognition performance of this technology heavily relies on the quality of finger vein images and on the recognition algorithm. To achieve efficient recognition performance, a special finger vein imaging device is developed, and a finger vein recognition method based on sparse representation is proposed. The motivation for the proposed method is that finger vein images exhibit a sparse property. In the proposed system, the regions of interest (ROIs) in the finger vein images are segmented and enhanced. Sparse representation and sparsity preserving projection on ROIs are performed to obtain the features. Finally, the features are measured for recognition. An equal error rate of 0.017% was achieved based on the finger vein image database, which contains images that were captured by using the near-IR imaging device that was developed in this study. The experimental results demonstrate that the proposed method is faster and more robust than previous methods.
Finger vein recognition based on personalized weight maps.
Yang, Gongping; Xiao, Rongyang; Yin, Yilong; Yang, Lu
2013-09-10
Finger vein recognition is a promising biometric recognition technology, which verifies identities via the vein patterns in the fingers. Binary pattern based methods were thoroughly studied in order to cope with the difficulties of extracting the blood vessel network. However, current binary pattern based finger vein matching methods treat every bit of feature codes derived from different image of various individuals as equally important and assign the same weight value to them. In this paper, we propose a finger vein recognition method based on personalized weight maps (PWMs). The different bits have different weight values according to their stabilities in a certain number of training samples from an individual. Firstly we present the concept of PWM, and then propose the finger vein recognition framework, which mainly consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PWM achieves not only better performance, but also high robustness and reliability. In addition, PWM can be used as a general framework for binary pattern based recognition.
Finger Vein Recognition Based on Personalized Weight Maps
Yang, Gongping; Xiao, Rongyang; Yin, Yilong; Yang, Lu
2013-01-01
Finger vein recognition is a promising biometric recognition technology, which verifies identities via the vein patterns in the fingers. Binary pattern based methods were thoroughly studied in order to cope with the difficulties of extracting the blood vessel network. However, current binary pattern based finger vein matching methods treat every bit of feature codes derived from different image of various individuals as equally important and assign the same weight value to them. In this paper, we propose a finger vein recognition method based on personalized weight maps (PWMs). The different bits have different weight values according to their stabilities in a certain number of training samples from an individual. Firstly we present the concept of PWM, and then propose the finger vein recognition framework, which mainly consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PWM achieves not only better performance, but also high robustness and reliability. In addition, PWM can be used as a general framework for binary pattern based recognition. PMID:24025556
Xie, Shan Juan; Lu, Yu; Yoon, Sook; Yang, Jucheng; Park, Dong Sun
2015-01-01
Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc.) vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs). In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV) normalization method using guided filter based single scale retinex (GFSSR) is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy. PMID:26184226
Xie, Shan Juan; Lu, Yu; Yoon, Sook; Yang, Jucheng; Park, Dong Sun
2015-07-14
Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc.) vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs). In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV) normalization method using guided filter based single scale retinex (GFSSR) is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy.
Spoof Detection for Finger-Vein Recognition System Using NIR Camera.
Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung
2017-10-01
Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN-based methods and other previous handcrafted methods.
Spoof Detection for Finger-Vein Recognition System Using NIR Camera
Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung
2017-01-01
Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN-based methods and other previous handcrafted methods. PMID:28974031
Finger Vein Recognition Based on a Personalized Best Bit Map
Yang, Gongping; Xi, Xiaoming; Yin, Yilong
2012-01-01
Finger vein patterns have recently been recognized as an effective biometric identifier. In this paper, we propose a finger vein recognition method based on a personalized best bit map (PBBM). Our method is rooted in a local binary pattern based method and then inclined to use the best bits only for matching. We first present the concept of PBBM and the generating algorithm. Then we propose the finger vein recognition framework, which consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PBBM achieves not only better performance, but also high robustness and reliability. In addition, PBBM can be used as a general framework for binary pattern based recognition. PMID:22438735
Finger vein recognition based on a personalized best bit map.
Yang, Gongping; Xi, Xiaoming; Yin, Yilong
2012-01-01
Finger vein patterns have recently been recognized as an effective biometric identifier. In this paper, we propose a finger vein recognition method based on a personalized best bit map (PBBM). Our method is rooted in a local binary pattern based method and then inclined to use the best bits only for matching. We first present the concept of PBBM and the generating algorithm. Then we propose the finger vein recognition framework, which consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PBBM achieves not only better performance, but also high robustness and reliability. In addition, PBBM can be used as a general framework for binary pattern based recognition.
Palm vein recognition based on directional empirical mode decomposition
NASA Astrophysics Data System (ADS)
Lee, Jen-Chun; Chang, Chien-Ping; Chen, Wei-Kuei
2014-04-01
Directional empirical mode decomposition (DEMD) has recently been proposed to make empirical mode decomposition suitable for the processing of texture analysis. Using DEMD, samples are decomposed into a series of images, referred to as two-dimensional intrinsic mode functions (2-D IMFs), from finer to large scale. A DEMD-based 2 linear discriminant analysis (LDA) for palm vein recognition is proposed. The proposed method progresses through three steps: (i) a set of 2-D IMF features of various scale and orientation are extracted using DEMD, (ii) the 2LDA method is then applied to reduce the dimensionality of the feature space in both the row and column directions, and (iii) the nearest neighbor classifier is used for classification. We also propose two strategies for using the set of 2-D IMF features: ensemble DEMD vein representation (EDVR) and multichannel DEMD vein representation (MDVR). In experiments using palm vein databases, the proposed MDVR-based 2LDA method achieved recognition accuracy of 99.73%, thereby demonstrating its feasibility for palm vein recognition.
Fuzzy based finger vein recognition with rotation invariant feature matching
NASA Astrophysics Data System (ADS)
Ezhilmaran, D.; Joseph, Rose Bindu
2017-11-01
Finger vein recognition is a promising biometric with commercial applications which is explored widely in the recent years. In this paper, a finger vein recognition system is proposed using rotation invariant feature descriptors for matching after enhancing the finger vein images with an interval type-2 fuzzy method. SIFT features are extracted and matched using a matching score based on Euclidian distance. Rotation invariance of the proposed method is verified in the experiment and the results are compared with SURF matching and minutiae matching. It is seen that rotation invariance is verified and the poor quality issues are solved efficiently with the designed system of finger vein recognition during the analysis. The experiments underlines the robustness and reliability of the interval type-2 fuzzy enhancement and SIFT feature matching.
Finger Vein Recognition Based on Local Directional Code
Meng, Xianjing; Yang, Gongping; Yin, Yilong; Xiao, Rongyang
2012-01-01
Finger vein patterns are considered as one of the most promising biometric authentication methods for its security and convenience. Most of the current available finger vein recognition methods utilize features from a segmented blood vessel network. As an improperly segmented network may degrade the recognition accuracy, binary pattern based methods are proposed, such as Local Binary Pattern (LBP), Local Derivative Pattern (LDP) and Local Line Binary Pattern (LLBP). However, the rich directional information hidden in the finger vein pattern has not been fully exploited by the existing local patterns. Inspired by the Webber Local Descriptor (WLD), this paper represents a new direction based local descriptor called Local Directional Code (LDC) and applies it to finger vein recognition. In LDC, the local gradient orientation information is coded as an octonary decimal number. Experimental results show that the proposed method using LDC achieves better performance than methods using LLBP. PMID:23202194
Finger vein recognition based on local directional code.
Meng, Xianjing; Yang, Gongping; Yin, Yilong; Xiao, Rongyang
2012-11-05
Finger vein patterns are considered as one of the most promising biometric authentication methods for its security and convenience. Most of the current available finger vein recognition methods utilize features from a segmented blood vessel network. As an improperly segmented network may degrade the recognition accuracy, binary pattern based methods are proposed, such as Local Binary Pattern (LBP), Local Derivative Pattern (LDP) and Local Line Binary Pattern (LLBP). However, the rich directional information hidden in the finger vein pattern has not been fully exploited by the existing local patterns. Inspired by the Webber Local Descriptor (WLD), this paper represents a new direction based local descriptor called Local Directional Code (LDC) and applies it to finger vein recognition. In LDC, the local gradient orientation information is coded as an octonary decimal number. Experimental results show that the proposed method using LDC achieves better performance than methods using LLBP.
Contact-free palm-vein recognition based on local invariant features.
Kang, Wenxiong; Liu, Yang; Wu, Qiuxia; Yue, Xishun
2014-01-01
Contact-free palm-vein recognition is one of the most challenging and promising areas in hand biometrics. In view of the existing problems in contact-free palm-vein imaging, including projection transformation, uneven illumination and difficulty in extracting exact ROIs, this paper presents a novel recognition approach for contact-free palm-vein recognition that performs feature extraction and matching on all vein textures distributed over the palm surface, including finger veins and palm veins, to minimize the loss of feature information. First, a hierarchical enhancement algorithm, which combines a DOG filter and histogram equalization, is adopted to alleviate uneven illumination and to highlight vein textures. Second, RootSIFT, a more stable local invariant feature extraction method in comparison to SIFT, is adopted to overcome the projection transformation in contact-free mode. Subsequently, a novel hierarchical mismatching removal algorithm based on neighborhood searching and LBP histograms is adopted to improve the accuracy of feature matching. Finally, we rigorously evaluated the proposed approach using two different databases and obtained 0.996% and 3.112% Equal Error Rates (EERs), respectively, which demonstrate the effectiveness of the proposed approach.
Contact-Free Palm-Vein Recognition Based on Local Invariant Features
Kang, Wenxiong; Liu, Yang; Wu, Qiuxia; Yue, Xishun
2014-01-01
Contact-free palm-vein recognition is one of the most challenging and promising areas in hand biometrics. In view of the existing problems in contact-free palm-vein imaging, including projection transformation, uneven illumination and difficulty in extracting exact ROIs, this paper presents a novel recognition approach for contact-free palm-vein recognition that performs feature extraction and matching on all vein textures distributed over the palm surface, including finger veins and palm veins, to minimize the loss of feature information. First, a hierarchical enhancement algorithm, which combines a DOG filter and histogram equalization, is adopted to alleviate uneven illumination and to highlight vein textures. Second, RootSIFT, a more stable local invariant feature extraction method in comparison to SIFT, is adopted to overcome the projection transformation in contact-free mode. Subsequently, a novel hierarchical mismatching removal algorithm based on neighborhood searching and LBP histograms is adopted to improve the accuracy of feature matching. Finally, we rigorously evaluated the proposed approach using two different databases and obtained 0.996% and 3.112% Equal Error Rates (EERs), respectively, which demonstrate the effectiveness of the proposed approach. PMID:24866176
Scattering Removal for Finger-Vein Image Restoration
Yang, Jinfeng; Zhang, Ben; Shi, Yihua
2012-01-01
Finger-vein recognition has received increased attention recently. However, the finger-vein images are always captured in poor quality. This certainly makes finger-vein feature representation unreliable, and further impairs the accuracy of finger-vein recognition. In this paper, we first give an analysis of the intrinsic factors causing finger-vein image degradation, and then propose a simple but effective image restoration method based on scattering removal. To give a proper description of finger-vein image degradation, a biological optical model (BOM) specific to finger-vein imaging is proposed according to the principle of light propagation in biological tissues. Based on BOM, the light scattering component is sensibly estimated and properly removed for finger-vein image restoration. Finally, experimental results demonstrate that the proposed method is powerful in enhancing the finger-vein image contrast and in improving the finger-vein image matching accuracy. PMID:22737028
Finger vein recognition based on finger crease location
NASA Astrophysics Data System (ADS)
Lu, Zhiying; Ding, Shumeng; Yin, Jing
2016-07-01
Finger vein recognition technology has significant advantages over other methods in terms of accuracy, uniqueness, and stability, and it has wide promising applications in the field of biometric recognition. We propose using finger creases to locate and extract an object region. Then we use linear fitting to overcome the problem of finger rotation in the plane. The method of modular adaptive histogram equalization (MAHE) is presented to enhance image contrast and reduce computational cost. To extract the finger vein features, we use a fusion method, which can obtain clear and distinguishable vein patterns under different conditions. We used the Hausdorff average distance algorithm to examine the recognition performance of the system. The experimental results demonstrate that MAHE can better balance the recognition accuracy and the expenditure of time compared with three other methods. Our resulting equal error rate throughout the total procedure was 3.268% in a database of 153 finger vein images.
Palm-Vein Classification Based on Principal Orientation Features
Zhou, Yujia; Liu, Yaqin; Feng, Qianjin; Yang, Feng; Huang, Jing; Nie, Yixiao
2014-01-01
Personal recognition using palm–vein patterns has emerged as a promising alternative for human recognition because of its uniqueness, stability, live body identification, flexibility, and difficulty to cheat. With the expanding application of palm–vein pattern recognition, the corresponding growth of the database has resulted in a long response time. To shorten the response time of identification, this paper proposes a simple and useful classification for palm–vein identification based on principal direction features. In the registration process, the Gaussian-Radon transform is adopted to extract the orientation matrix and then compute the principal direction of a palm–vein image based on the orientation matrix. The database can be classified into six bins based on the value of the principal direction. In the identification process, the principal direction of the test sample is first extracted to ascertain the corresponding bin. One-by-one matching with the training samples is then performed in the bin. To improve recognition efficiency while maintaining better recognition accuracy, two neighborhood bins of the corresponding bin are continuously searched to identify the input palm–vein image. Evaluation experiments are conducted on three different databases, namely, PolyU, CASIA, and the database of this study. Experimental results show that the searching range of one test sample in PolyU, CASIA and our database by the proposed method for palm–vein identification can be reduced to 14.29%, 14.50%, and 14.28%, with retrieval accuracy of 96.67%, 96.00%, and 97.71%, respectively. With 10,000 training samples in the database, the execution time of the identification process by the traditional method is 18.56 s, while that by the proposed approach is 3.16 s. The experimental results confirm that the proposed approach is more efficient than the traditional method, especially for a large database. PMID:25383715
Multimodal biometric method that combines veins, prints, and shape of a finger
NASA Astrophysics Data System (ADS)
Kang, Byung Jun; Park, Kang Ryoung; Yoo, Jang-Hee; Kim, Jeong Nyeo
2011-01-01
Multimodal biometrics provides high recognition accuracy and population coverage by using various biometric features. A single finger contains finger veins, fingerprints, and finger geometry features; by using multimodal biometrics, information on these multiple features can be simultaneously obtained in a short time and their fusion can outperform the use of a single feature. This paper proposes a new finger recognition method based on the score-level fusion of finger veins, fingerprints, and finger geometry features. This research is novel in the following four ways. First, the performances of the finger-vein and fingerprint recognition are improved by using a method based on a local derivative pattern. Second, the accuracy of the finger geometry recognition is greatly increased by combining a Fourier descriptor with principal component analysis. Third, a fuzzy score normalization method is introduced; its performance is better than the conventional Z-score normalization method. Fourth, finger-vein, fingerprint, and finger geometry recognitions are combined by using three support vector machines and a weighted SUM rule. Experimental results showed that the equal error rate of the proposed method was 0.254%, which was lower than those of the other methods.
Finger-vein and fingerprint recognition based on a feature-level fusion method
NASA Astrophysics Data System (ADS)
Yang, Jinfeng; Hong, Bofeng
2013-07-01
Multimodal biometrics based on the finger identification is a hot topic in recent years. In this paper, a novel fingerprint-vein based biometric method is proposed to improve the reliability and accuracy of the finger recognition system. First, the second order steerable filters are used here to enhance and extract the minutiae features of the fingerprint (FP) and finger-vein (FV). Second, the texture features of fingerprint and finger-vein are extracted by a bank of Gabor filter. Third, a new triangle-region fusion method is proposed to integrate all the fingerprint and finger-vein features in feature-level. Thus, the fusion features contain both the finger texture-information and the minutiae triangular geometry structure. Finally, experimental results performed on the self-constructed finger-vein and fingerprint databases are shown that the proposed method is reliable and precise in personal identification.
Finger-Vein Image Enhancement Using a Fuzzy-Based Fusion Method with Gabor and Retinex Filtering
Shin, Kwang Yong; Park, Young Ho; Nguyen, Dat Tien; Park, Kang Ryoung
2014-01-01
Because of the advantages of finger-vein recognition systems such as live detection and usage as bio-cryptography systems, they can be used to authenticate individual people. However, images of finger-vein patterns are typically unclear because of light scattering by the skin, optical blurring, and motion blurring, which can degrade the performance of finger-vein recognition systems. In response to these issues, a new enhancement method for finger-vein images is proposed. Our method is novel compared with previous approaches in four respects. First, the local and global features of the vein lines of an input image are amplified using Gabor filters in four directions and Retinex filtering, respectively. Second, the means and standard deviations in the local windows of the images produced after Gabor and Retinex filtering are used as inputs for the fuzzy rule and fuzzy membership function, respectively. Third, the optimal weights required to combine the two Gabor and Retinex filtered images are determined using a defuzzification method. Fourth, the use of a fuzzy-based method means that image enhancement does not require additional training data to determine the optimal weights. Experimental results using two finger-vein databases showed that the proposed method enhanced the accuracy of finger-vein recognition compared with previous methods. PMID:24549251
Compressed sensing approach for wrist vein biometrics.
Lantsov, Aleksey; Ryabko, Maxim; Shchekin, Aleksey
2018-04-01
The work describes features of the compressed sensing (CS) approach utilized for development of a wearable system for wrist vein recognition with single-pixel detection; we consider this system useful for biometrics authentication purposes. The CS approach implies use of a spatial light modulation (SLM) which, in our case, can be performed differently-with a liquid crystal display or diffusely scattering medium. We show that compressed sensing combined with above-mentioned means of SLM allows us to avoid using an optical system-a limiting factor for wearable devices. The trade-off between the 2 different SLM approaches regarding issues of practical implementation of CS approach for wrist vein recognition purposes is discussed. A possible solution of a misalignment problem-a typical issue for imaging systems based upon 2D arrays of photodiodes-is also proposed. Proposed design of the wearable device for wrist vein recognition is based upon single-pixel detection. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
An improved finger-vein recognition algorithm based on template matching
NASA Astrophysics Data System (ADS)
Liu, Yueyue; Di, Si; Jin, Jian; Huang, Daoping
2016-10-01
Finger-vein recognition has became the most popular biometric identify methods. The investigation on the recognition algorithms always is the key point in this field. So far, there are many applicable algorithms have been developed. However, there are still some problems in practice, such as the variance of the finger position which may lead to the image distortion and shifting; during the identification process, some matching parameters determined according to experience may also reduce the adaptability of algorithm. Focus on above mentioned problems, this paper proposes an improved finger-vein recognition algorithm based on template matching. In order to enhance the robustness of the algorithm for the image distortion, the least squares error method is adopted to correct the oblique finger. During the feature extraction, local adaptive threshold method is adopted. As regard as the matching scores, we optimized the translation preferences as well as matching distance between the input images and register images on the basis of Naoto Miura algorithm. Experimental results indicate that the proposed method can improve the robustness effectively under the finger shifting and rotation conditions.
Pattern recognition tool based on complex network-based approach
NASA Astrophysics Data System (ADS)
Casanova, Dalcimar; Backes, André Ricardo; Martinez Bruno, Odemir
2013-02-01
This work proposed a generalization of the method proposed by the authors: 'A complex network-based approach for boundary shape analysis'. Instead of modelling a contour into a graph and use complex networks rules to characterize it, here, we generalize the technique. This way, the work proposes a mathematical tool for characterization signals, curves and set of points. To evaluate the pattern description power of the proposal, an experiment of plat identification based on leaf veins image are conducted. Leaf vein is a taxon characteristic used to plant identification proposes, and one of its characteristics is that these structures are complex, and difficult to be represented as a signal or curves and this way to be analyzed in a classical pattern recognition approach. Here, we model the veins as a set of points and model as graphs. As features, we use the degree and joint degree measurements in a dynamic evolution. The results demonstrates that the technique has a good power of discrimination and can be used for plant identification, as well as other complex pattern recognition tasks.
Pham, Tuyen Danh; Park, Young Ho; Nguyen, Dat Tien; Kwon, Seung Yong; Park, Kang Ryoung
2015-01-01
Biometrics is a technology that enables an individual person to be identified based on human physiological and behavioral characteristics. Among biometrics technologies, face recognition has been widely used because of its advantages in terms of convenience and non-contact operation. However, its performance is affected by factors such as variation in the illumination, facial expression, and head pose. Therefore, fingerprint and iris recognitions are preferred alternatives. However, the performance of the former can be adversely affected by the skin condition, including scarring and dryness. In addition, the latter has the disadvantages of high cost, large system size, and inconvenience to the user, who has to align their eyes with the iris camera. In an attempt to overcome these problems, finger-vein recognition has been vigorously researched, but an analysis of its accuracies according to various factors has not received much attention. Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR) image sensor and analyze its accuracies considering various factors. The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands. PMID:26184214
Pham, Tuyen Danh; Park, Young Ho; Nguyen, Dat Tien; Kwon, Seung Yong; Park, Kang Ryoung
2015-07-13
Biometrics is a technology that enables an individual person to be identified based on human physiological and behavioral characteristics. Among biometrics technologies, face recognition has been widely used because of its advantages in terms of convenience and non-contact operation. However, its performance is affected by factors such as variation in the illumination, facial expression, and head pose. Therefore, fingerprint and iris recognitions are preferred alternatives. However, the performance of the former can be adversely affected by the skin condition, including scarring and dryness. In addition, the latter has the disadvantages of high cost, large system size, and inconvenience to the user, who has to align their eyes with the iris camera. In an attempt to overcome these problems, finger-vein recognition has been vigorously researched, but an analysis of its accuracies according to various factors has not received much attention. Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR) image sensor and analyze its accuracies considering various factors. The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands.
Research and implementation of finger-vein recognition algorithm
NASA Astrophysics Data System (ADS)
Pang, Zengyao; Yang, Jie; Chen, Yilei; Liu, Yin
2017-06-01
In finger vein image preprocessing, finger angle correction and ROI extraction are important parts of the system. In this paper, we propose an angle correction algorithm based on the centroid of the vein image, and extract the ROI region according to the bidirectional gray projection method. Inspired by the fact that features in those vein areas have similar appearance as valleys, a novel method was proposed to extract center and width of palm vein based on multi-directional gradients, which is easy-computing, quick and stable. On this basis, an encoding method was designed to determine the gray value distribution of texture image. This algorithm could effectively overcome the edge of the texture extraction error. Finally, the system was equipped with higher robustness and recognition accuracy by utilizing fuzzy threshold determination and global gray value matching algorithm. Experimental results on pairs of matched palm images show that, the proposed method has a EER with 3.21% extracts features at the speed of 27ms per image. It can be concluded that the proposed algorithm has obvious advantages in grain extraction efficiency, matching accuracy and algorithm efficiency.
Infrared Cephalic-Vein to Assist Blood Extraction Tasks: Automatic Projection and Recognition
NASA Astrophysics Data System (ADS)
Lagüela, S.; Gesto, M.; Riveiro, B.; González-Aguilera, D.
2017-05-01
Thermal infrared band is not commonly used in photogrammetric and computer vision algorithms, mainly due to the low spatial resolution of this type of imagery. However, this band captures sub-superficial information, increasing the capabilities of visible bands regarding applications. This fact is especially important in biomedicine and biometrics, allowing the geometric characterization of interior organs and pathologies with photogrammetric principles, as well as the automatic identification and labelling using computer vision algorithms. This paper presents advances of close-range photogrammetry and computer vision applied to thermal infrared imagery, with the final application of Augmented Reality in order to widen its application in the biomedical field. In this case, the thermal infrared image of the arm is acquired and simultaneously projected on the arm, together with the identification label of the cephalic-vein. This way, blood analysts are assisted in finding the vein for blood extraction, especially in those cases where the identification by the human eye is a complex task. Vein recognition is performed based on the Gaussian temperature distribution in the area of the vein, while the calibration between projector and thermographic camera is developed through feature extraction and pattern recognition. The method is validated through its application to a set of volunteers, with different ages and genres, in such way that different conditions of body temperature and vein depth are covered for the applicability and reproducibility of the method.
Finger vein recognition based on the hyperinformation feature
NASA Astrophysics Data System (ADS)
Xi, Xiaoming; Yang, Gongping; Yin, Yilong; Yang, Lu
2014-01-01
The finger vein is a promising biometric pattern for personal identification due to its advantages over other existing biometrics. In finger vein recognition, feature extraction is a critical step, and many feature extraction methods have been proposed to extract the gray, texture, or shape of the finger vein. We treat them as low-level features and present a high-level feature extraction framework. Under this framework, base attribute is first defined to represent the characteristics of a certain subcategory of a subject. Then, for an image, the correlation coefficient is used for constructing the high-level feature, which reflects the correlation between this image and all base attributes. Since the high-level feature can reveal characteristics of more subcategories and contain more discriminative information, we call it hyperinformation feature (HIF). Compared with low-level features, which only represent the characteristics of one subcategory, HIF is more powerful and robust. In order to demonstrate the potential of the proposed framework, we provide a case study to extract HIF. We conduct comprehensive experiments to show the generality of the proposed framework and the efficiency of HIF on our databases, respectively. Experimental results show that HIF significantly outperforms the low-level features.
NASA Astrophysics Data System (ADS)
Elnasir, Selma; Shamsuddin, Siti Mariyam; Farokhi, Sajad
2015-01-01
Palm vein recognition (PVR) is a promising new biometric that has been applied successfully as a method of access control by many organizations, which has even further potential in the field of forensics. The palm vein pattern has highly discriminative features that are difficult to forge because of its subcutaneous position in the palm. Despite considerable progress and a few practical issues, providing accurate palm vein readings has remained an unsolved issue in biometrics. We propose a robust and more accurate PVR method based on the combination of wavelet scattering (WS) with spectral regression kernel discriminant analysis (SRKDA). As the dimension of WS generated features is quite large, SRKDA is required to reduce the extracted features to enhance the discrimination. The results based on two public databases-PolyU Hyper Spectral Palmprint public database and PolyU Multi Spectral Palmprint-show the high performance of the proposed scheme in comparison with state-of-the-art methods. The proposed approach scored a 99.44% identification rate and a 99.90% verification rate [equal error rate (EER)=0.1%] for the hyperspectral database and a 99.97% identification rate and a 99.98% verification rate (EER=0.019%) for the multispectral database.
Finger vein recognition with personalized feature selection.
Xi, Xiaoming; Yang, Gongping; Yin, Yilong; Meng, Xianjing
2013-08-22
Finger veins are a promising biometric pattern for personalized identification in terms of their advantages over existing biometrics. Based on the spatial pyramid representation and the combination of more effective information such as gray, texture and shape, this paper proposes a simple but powerful feature, called Pyramid Histograms of Gray, Texture and Orientation Gradients (PHGTOG). For a finger vein image, PHGTOG can reflect the global spatial layout and local details of gray, texture and shape. To further improve the recognition performance and reduce the computational complexity, we select a personalized subset of features from PHGTOG for each subject by using the sparse weight vector, which is trained by using LASSO and called PFS-PHGTOG. We conduct extensive experiments to demonstrate the promise of the PHGTOG and PFS-PHGTOG, experimental results on our databases show that PHGTOG outperforms the other existing features. Moreover, PFS-PHGTOG can further boost the performance in comparison with PHGTOG.
Finger Vein Recognition with Personalized Feature Selection
Xi, Xiaoming; Yang, Gongping; Yin, Yilong; Meng, Xianjing
2013-01-01
Finger veins are a promising biometric pattern for personalized identification in terms of their advantages over existing biometrics. Based on the spatial pyramid representation and the combination of more effective information such as gray, texture and shape, this paper proposes a simple but powerful feature, called Pyramid Histograms of Gray, Texture and Orientation Gradients (PHGTOG). For a finger vein image, PHGTOG can reflect the global spatial layout and local details of gray, texture and shape. To further improve the recognition performance and reduce the computational complexity, we select a personalized subset of features from PHGTOG for each subject by using the sparse weight vector, which is trained by using LASSO and called PFS-PHGTOG. We conduct extensive experiments to demonstrate the promise of the PHGTOG and PFS-PHGTOG, experimental results on our databases show that PHGTOG outperforms the other existing features. Moreover, PFS-PHGTOG can further boost the performance in comparison with PHGTOG. PMID:23974154
Personal authentication through dorsal hand vein patterns
NASA Astrophysics Data System (ADS)
Hsu, Chih-Bin; Hao, Shu-Sheng; Lee, Jen-Chun
2011-08-01
Biometric identification is an emerging technology that can solve security problems in our networked society. A reliable and robust personal verification approach using dorsal hand vein patterns is proposed in this paper. The characteristic of the approach needs less computational and memory requirements and has a higher recognition accuracy. In our work, the near-infrared charge-coupled device (CCD) camera is adopted as an input device for capturing dorsal hand vein images, it has the advantages of the low-cost and noncontact imaging. In the proposed approach, two finger-peaks are automatically selected as the datum points to define the region of interest (ROI) in the dorsal hand vein images. The modified two-directional two-dimensional principal component analysis, which performs an alternate two-dimensional PCA (2DPCA) in the column direction of images in the 2DPCA subspace, is proposed to exploit the correlation of vein features inside the ROI between images. The major advantage of the proposed method is that it requires fewer coefficients for efficient dorsal hand vein image representation and recognition. The experimental results on our large dorsal hand vein database show that the presented schema achieves promising performance (false reject rate: 0.97% and false acceptance rate: 0.05%) and is feasible for dorsal hand vein recognition.
Finger vein recognition using local line binary pattern.
Rosdi, Bakhtiar Affendi; Shing, Chai Wuh; Suandi, Shahrel Azmin
2011-01-01
In this paper, a personal verification method using finger vein is presented. Finger vein can be considered more secured compared to other hands based biometric traits such as fingerprint and palm print because the features are inside the human body. In the proposed method, a new texture descriptor called local line binary pattern (LLBP) is utilized as feature extraction technique. The neighbourhood shape in LLBP is a straight line, unlike in local binary pattern (LBP) which is a square shape. Experimental results show that the proposed method using LLBP has better performance than the previous methods using LBP and local derivative pattern (LDP).
The biometric recognition on contactless multi-spectrum finger images
NASA Astrophysics Data System (ADS)
Kang, Wenxiong; Chen, Xiaopeng; Wu, Qiuxia
2015-01-01
This paper presents a novel multimodal biometric system based on contactless multi-spectrum finger images, which aims to deal with the limitations of unimodal biometrics. The chief merits of the system are the richness of the permissible texture and the ease of data access. We constructed a multi-spectrum instrument to simultaneously acquire three different types of biometrics from a finger: contactless fingerprint, finger vein, and knuckleprint. On the basis of the samples with these characteristics, a moderate database was built for the evaluation of our system. Considering the real-time requirements and the respective characteristics of the three biometrics, the block local binary patterns algorithm was used to extract features and match for the fingerprints and finger veins, while the Oriented FAST and Rotated BRIEF algorithm was applied for knuckleprints. Finally, score-level fusion was performed on the matching results from the aforementioned three types of biometrics. The experiments showed that our proposed multimodal biometric recognition system achieves an equal error rate of 0.109%, which is 88.9%, 94.6%, and 89.7% lower than the individual fingerprint, knuckleprint, and finger vein recognitions, respectively. Nevertheless, our proposed system also satisfies the real-time requirements of the applications.
Survey of Technologies for the Airport Border of the Future
2014-04-01
geometry Handwriting recognition ID cards Image classification Image enhancement Image fusion Image matching Image processing Image segmentation Iris...00 Tongue print Footstep recognition Odour recognition Retinal recognition Emotion recognition Periocular recognition Handwriting recognition Ear...recognition Palmprint recognition Hand geometry DNA matching Vein matching Ear recognition Handwriting recognition Periocular recognition Emotion
Finger Vein Recognition Using Local Line Binary Pattern
Rosdi, Bakhtiar Affendi; Shing, Chai Wuh; Suandi, Shahrel Azmin
2011-01-01
In this paper, a personal verification method using finger vein is presented. Finger vein can be considered more secured compared to other hands based biometric traits such as fingerprint and palm print because the features are inside the human body. In the proposed method, a new texture descriptor called local line binary pattern (LLBP) is utilized as feature extraction technique. The neighbourhood shape in LLBP is a straight line, unlike in local binary pattern (LBP) which is a square shape. Experimental results show that the proposed method using LLBP has better performance than the previous methods using LBP and local derivative pattern (LDP). PMID:22247670
Sliding Window-Based Region of Interest Extraction for Finger Vein Images
Yang, Lu; Yang, Gongping; Yin, Yilong; Xiao, Rongyang
2013-01-01
Region of Interest (ROI) extraction is a crucial step in an automatic finger vein recognition system. The aim of ROI extraction is to decide which part of the image is suitable for finger vein feature extraction. This paper proposes a finger vein ROI extraction method which is robust to finger displacement and rotation. First, we determine the middle line of the finger, which will be used to correct the image skew. Then, a sliding window is used to detect the phalangeal joints and further to ascertain the height of ROI. Last, for the corrective image with certain height, we will obtain the ROI by using the internal tangents of finger edges as the left and right boundary. The experimental results show that the proposed method can extract ROI more accurately and effectively compared with other methods, and thus improve the performance of finger vein identification system. Besides, to acquire the high quality finger vein image during the capture process, we propose eight criteria for finger vein capture from different aspects and these criteria should be helpful to some extent for finger vein capture. PMID:23507824
Miocene Lonchocarpus (Papilionoideae) in San Esteban Tizatlán, Tlaxcala, Mexico
NASA Astrophysics Data System (ADS)
Hernández-Damián, Ana Lilia; Calvillo-Canadell, Laura; Cevallos-Ferriz, Sergio R. S.; Sousa, Mario
2016-03-01
New leaflets from San Esteban Tizatlán, Tlaxcala, Mexico, are described and identified based on their leaf architecture. They have elliptic leaflets with pulvinate petiolule, entire margin, convex apex and base, well developed primary and craspedodromous secondary venation, with decurrent secondary veins with fused the mid-vein, a pair of obtuse basal veins, weak intersecundary veins, mixed percurrent tertiary venation dominated by the opposite type with sinuous course, alternate percurrent fourth-order venation, regular reticulate with few non ramified veinlets. All these characteristics are closely compared with members of sections Obtusifolii and Standleyi of Lonchocarpus (Leguminosae, Papillionoideae, Millettieae), but the mosaic of characters found in the fossil material granted recognition of a new species Lonchocarpus miocenicus sp. nov. This new record of Lonchocarpus from central Mexico further supports the presence of an evergreen tropical forest during the Miocene in the area, a plant community that developed from the Boreotropical Flora and contributed latter to the Neotropical Flora.
Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor
Nguyen, Dat Tien; Baek, Na Rae; Pham, Tuyen Danh; Park, Kang Ryoung
2018-01-01
Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD) method for an iris recognition system (iPAD) using a near infrared light (NIR) camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED). Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM). Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies. PMID:29695113
Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor.
Nguyen, Dat Tien; Baek, Na Rae; Pham, Tuyen Danh; Park, Kang Ryoung
2018-04-24
Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD) method for an iris recognition system (iPAD) using a near infrared light (NIR) camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED). Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM). Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies.
Cloud based emergency health care information service in India.
Karthikeyan, N; Sukanesh, R
2012-12-01
A hospital is a health care organization providing patient treatment by expert physicians, surgeons and equipments. A report from a health care accreditation group says that miscommunication between patients and health care providers is the reason for the gap in providing emergency medical care to people in need. In developing countries, illiteracy is the major key root for deaths resulting from uncertain diseases constituting a serious public health problem. Mentally affected, differently abled and unconscious patients can't communicate about their medical history to the medical practitioners. Also, Medical practitioners can't edit or view DICOM images instantly. Our aim is to provide palm vein pattern recognition based medical record retrieval system, using cloud computing for the above mentioned people. Distributed computing technology is coming in the new forms as Grid computing and Cloud computing. These new forms are assured to bring Information Technology (IT) as a service. In this paper, we have described how these new forms of distributed computing will be helpful for modern health care industries. Cloud Computing is germinating its benefit to industrial sectors especially in medical scenarios. In Cloud Computing, IT-related capabilities and resources are provided as services, via the distributed computing on-demand. This paper is concerned with sprouting software as a service (SaaS) by means of Cloud computing with an aim to bring emergency health care sector in an umbrella with physical secured patient records. In framing the emergency healthcare treatment, the crucial thing considered necessary to decide about patients is their previous health conduct records. Thus a ubiquitous access to appropriate records is essential. Palm vein pattern recognition promises a secured patient record access. Likewise our paper reveals an efficient means to view, edit or transfer the DICOM images instantly which was a challenging task for medical practitioners in the past years. We have developed two services for health care. 1. Cloud based Palm vein recognition system 2. Distributed Medical image processing tools for medical practitioners.
An effective hand vein feature extraction method.
Li, Haigang; Zhang, Qian; Li, Chengdong
2015-01-01
As a new authentication method developed years ago, vein recognition technology features the unique advantage of bioassay. This paper studies the specific procedure for the extraction of hand back vein characteristics. There are different positions used in the collecting process, so that a suitable intravenous regional orientation method is put forward, allowing the positioning area to be the same for all hand positions. In addition, to eliminate the pseudo vein area, the valley regional shape extraction operator can be improved and combined with multiple segmentation algorithms. The images should be segmented step by step, making the vein texture to appear clear and accurate. Lastly, the segmented images should be filtered, eroded, and refined. This process helps to filter the most of the pseudo vein information. Finally, a clear vein skeleton diagram is obtained, demonstrating the effectiveness of the algorithm. This paper presents a hand back vein region location method. This makes it possible to rotate and correct the image by working out the inclination degree of contour at the side of hand back.
Yamashita, Rikiya; Yamaoka, Toshihide; Nishitai, Ryuta; Isoda, Hiroyoshi; Taura, Kojiro; Arizono, Shigeki; Furuta, Akihiro; Ohno, Tsuyoshi; Ono, Ayako; Togashi, Kaori
2017-07-01
This study aimed to evaluate the common features and variations of portal vein anatomy in right-sided round ligament (RSRL), which can help propose a method to detect and diagnose this anomaly. In this retrospective study of 14 patients with RSRL, the branching order of the portal tree was analyzed, with special focus on the relationship between the dorsal branch of the right anterior segmental portal vein (P A-D ) and the lateral segmental portal vein (P LL ), to determine the common features. The configuration of the portal vein from the main portal trunk to the right umbilical portion (RUP), the inclination of the RUP, and the number and thickness of the ramifications branching from the right anterior segmental portal vein (P A ) were evaluated for variations. In all subjects, the diverging point of the P A-D was constantly distal to that of the P LL . The portal vein configuration was I- and Z-shaped in nine and five subjects, respectively. The RUP was tilted to the right in all subjects. In Z-shaped subjects, the portal trunk between the branching point of the right posterior segmental portal vein and that of the P LL was tilted to the left in one subject and was almost parallel to the vertical plane in four subjects. Multiple ramifications were radially distributed from the P A in eight subjects, whereas one predominant P A-D branched from the P A in six subjects. Based on the diverging points of the P A-D and P LL , we proposed a three-step method for the detection and diagnosis of RSRL.
Early morning oedema in patients with primary varicose veins without trophic changes.
Rastel, Didier; Allaert, François-André
2016-11-01
Chronic lower limb oedema is one of the complications of superficial or deep chronic venous disorders. It is ranked as "C3"on the CEAP classification. In epidemiological studies, the recognition of oedema is mainly based on clinical signs, and oedema is more easily detected in the second part of the day when it becomes evident. We addressed the question whether oedema is already present in the morning in patients suffering of primary varicose veins without trophic changes. In total, 101 patients with primary varicose veins (C2 and/or C3 stage of the CEAP classification) and 122 controls were enrolled as they appeared in our centre. The consultation time was no later than 6 hours after the patient had woken up. Oedema was detected by pitting test and ultrasound. The mean consultation time lapse was 3.7 ± 1.2 hours after waking-up. Oedema was more frequent in the group of primary varicose veins without trophic changes (36 % compared to 14 % in the control group; p < 0.01). Oedema was mainly detected by ultrasound and far less so by the pitting test. Patients with varicose veins have morning oedema more frequently than patients without varicosis and at a higher rate than in epidemiological studies.
Medical information security in the era of artificial intelligence.
Wang, Yufeng; Wang, Liwei; Xue, Chang-Ao
2018-06-01
In recent years, biometric technologies, such as iris, facial, and finger vein recognition, have reached consumers and are being increasingly applied. However, it remains unknown whether these highly specific biometric technologies are as safe as declared by their manufacturers. As three-dimensional (3D) reconstruction based on medical imaging and 3D printing are being developed, these biometric technologies may face severe challenges. Copyright © 2018 Elsevier Ltd. All rights reserved.
Portal vein aneurysm in thalassaemia.
Das, Simi; Dey, Mousam; Kumar, Vinay; Lal, Hira
2017-08-11
Arterial aneurysms are more common than visceral venous aneurysms. Portal vein aneurysms being the most common type of visceral venous aneurysms. Here, we present an 18-year-old young woman with thalassaemia major, who presented with headache, palpitation, shortness of breath and a recent increase in blood transfusion rate. On clinical examination, she had hepatosplenomegaly. Ultrasonography revealed hepatosplenomegaly with fusiform dilatation of extrahepatic portal vein, which was confirmed to be portal vein aneurysm on contrast enhanced CT. Though portal vein aneurysms were previously thought to be rare, recently they are increasingly diagnosed with the use of cross-sectional imaging. Recognition of this finding can help to avoid potential confusion with other periportal cystic masses of different aetiologies, especially on sonography. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Retro-aortic left renal vein--an anatomic variation description and review of literature.
Suma, H Yekappa; Roopa, Kulkarni
2011-01-01
This study reports the presence of a retro-aortic renal vein on the left side draining into the inferior vena cava. This variation was observed during routine dissection in a female cadaver aged about 55 years. This variation is of importance because of its implications in renal transplantation, renal surgery, vascular surgery, uroradiology and gonadal surgeries. The knowledge of such variations can help the clinicians for its recognition and protection.
Analysis of the hand vein pattern for people recognition
NASA Astrophysics Data System (ADS)
Castro-Ortega, R.; Toxqui-Quitl, C.; Cristóbal, G.; Marcos, J. Victor; Padilla-Vivanco, A.; Hurtado Pérez, R.
2015-09-01
The shape of the hand vascular pattern contains useful and unique features that can be used for identifying and authenticating people, with applications in access control, medicine and financial services. In this work, an optical system for the image acquisition of the hand vascular pattern is implemented. It consists of a CCD camera with sensitivity in the IR and a light source with emission in the 880 nm. The IR radiation interacts with the desoxyhemoglobin, hemoglobin and water present in the blood of the veins, making possible to see the vein pattern underneath skin. The segmentation of the Region Of Interest (ROI) is achieved using geometrical moments locating the centroid of an image. For enhancement of the vein pattern we use the technique of Histogram Equalization and Contrast Limited Adaptive Histogram Equalization (CLAHE). In order to remove unnecessary information such as body hair and skinfolds, a low pass filter is implemented. A method based on geometric moments is used to obtain the invariant descriptors of the input images. The classification task is achieved using Artificial Neural Networks (ANN) and K-Nearest Neighbors (K-nn) algorithms. Experimental results using our database show a percentage of correct classification, higher of 86.36% with ANN for 912 images of 38 people with 12 versions each one.
NASA Astrophysics Data System (ADS)
Prijono, Agus; Darmawan Hangkawidjaja, Aan; Ratnadewi; Saleh Ahmar, Ansari
2018-01-01
The verification to person who is used today as a fingerprint, signature, personal identification number (PIN) in the bank system, identity cards, attendance, easily copied and forged. This causes the system not secure and is vulnerable to unauthorized persons to access the system. In this research will be implemented verification system using the image of the blood vessels in the back of the palms as recognition more difficult to imitate because it is located inside the human body so it is safer to use. The blood vessels located at the back of the human hand is unique, even humans twins have a different image of the blood vessels. Besides the image of the blood vessels do not depend on a person’s age, so it can be used for long term, except in the case of an accident, or disease. Because of the unique vein pattern recognition can be used in a person. In this paper, we used a modification method to perform the introduction of a person based on the image of the blood vessel that is using Modified Local Line Binary Pattern (MLLBP). The process of matching blood vessel image feature extraction using Hamming Distance. Test case of verification is done by calculating the percentage of acceptance of the same person. Rejection error occurs if a person was not matched by the system with the data itself. The 10 person with 15 image compared to 5 image vein for each person is resulted 80,67% successful Another test case of the verification is done by verified two image from different person that is forgery, and the verification will be true if the system can rejection the image forgery. The ten different person is not verified and the result is obtained 94%.
Pattern Recognition Of Blood Vessel Networks In Ocular Fundus Images
NASA Astrophysics Data System (ADS)
Akita, K.; Kuga, H.
1982-11-01
We propose a computer method of recognizing blood vessel networks in color ocular fundus images which are used in the mass diagnosis of adult diseases such as hypertension and diabetes. A line detection algorithm is applied to extract the blood vessels, and the skeleton patterns of them are made to analyze and describe their structures. The recognition of line segments of arteries and/or veins in the vessel networks consists of three stages. First, a few segments which satisfy a certain constraint are picked up and discriminated as arteries or veins. This is the initial labeling. Then the remaining unknown ones are labeled by utilizing the physical level knowledge. We propose two schemes for this stage : a deterministic labeling and a probabilistic relaxation labeling. Finally the label of each line segment is checked so as to minimize the total number of labeling contradictions. Some experimental results are also presented.
Noyes, Adam M; Dickey, John
2017-05-01
Upper extremity deep venous thrombosis (UEDVT) involves thrombosis of the deep veins of the arm as they enter the thorax. They are increasing in frequency, largely due to the rising use of central venous catheters and implantable cardiac devices, and represent more than 10% of all DVT cases, Upper extremity deep venous thrombosis has been historically misunderstood when compared to lower extremity deep vein thrombosis (LEDVT). Their associated disease states may carry devastating complications, with mortality rates often higher than that of LEDVT. Thus, education on recognition, classification and management is critical to avoid long-term sequelae and mortality from UEDVT. [Full article available at http://rimed.org/rimedicaljournal-2017-05.asp].
Acute appendicitis-like symptoms as initial presentation of ovarian vein thrombosis.
Prieto-Nieto, M I; Perez-Robledo, J P; Rodriguez-Montes, J A; Garci-Sancho-Martin, L
2004-07-01
Postpartum ovarian vein thrombosis is a rare condition, with an incidence rate being 1/600 deliveries. It most often arises in the right ovarian vein. A 33-year-old patient who had had normal vaginal delivery presented with fever, pain in the right iliac fossa, and leukocytosis on the sixth day after delivery. An antibiotic course was instituted but 3 days later symptoms reappeared. Diagnosis of acute appendicitis was made. At surgery through a McBurney incision, a woody tumoration consistent with ovarian vein thrombosis was found. Anticoagulation therapy with heparin and antibiotics were instituted. Phlebography and color Doppler sonography confirmed the presence of thrombosis of both the common femoral iliac and inferior vena cava. Fribrolysis with urokinase was performed. The patient has remained stable and symptom-free over a 4-year follow-up. Ovarian vein thrombosis typically presents with symptoms suggestive of acute appendicitis, as was the case in our patient. Color Doppler sonography is the favored diagnostic procedure, with CT being a supplementary tool. Surgery is not necessary and treatment consists of anticoagulants and antibiotics. Even though postpartum ovarian vein thrombosis is rare, early recognition of the condition is of paramount importance to institute the adequate treatment and avoid potential serious sequelae.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basavatia, A; Kalnicki, S; Garg, M
Purpose: To implement a clinically useful palm vein pattern recognition biometric system to treat the correct treatment plan to the correct patient each and every time and to check-in the patient into the department to access the correct medical record. Methods: A commercially available hand vein scanning system was paired to Aria and utilized an ADT interface from the hospital electronic health system. Integration at two points in Aria, version 11 MR2, first at the appointment tracker screen for the front desk medical record access and second at the queue screen on the 4D treatment console took place for patientmore » daily time-out. A test patient was utilized to check accuracy of identification as well as to check that no unintended interactions take place between the 4D treatment console and the hand vein scanning system. This system has been in clinical use since December 2013. Results: Since implementation, 445 patients have been enrolled into our biometric system. 95% of patients learn the correct methodology of hand placement on the scanner in the first try. We have had two instances of patient not found because of a bad initial scan. We simply erased the scanned metric and the patient enrolled again in those cases. The accuracy of the match is 100% for each patient, we have not had one patient misidentified. We can state this because we still use patient photo and date of birth as identifiers. A QA test patient is run monthly to check the integrity of the system. Conclusion: By utilizing palm vein scans along with the date of birth and patient photo, another means of patient identification now exits. This work indicates the successful implementation of technology in the area of patient safety by closing the gap of treating the wrong plan to a patient in radiation oncology. FOJP Service Corporation covered some of the costs of the hardware and software of the palm vein pattern recognition biometric system.« less
Pua, Uei
2014-10-01
Central venous perforation during dialysis catheter insertion is a potentially fatal complication. Prompt recognition and judicious initial steps are important in optimizing the outcome. The purpose of this manuscript is to illustrate the imaging features and steps in initial management. © 2014 International Society for Hemodialysis.
Yang, X; Chu, C W; Yang, J D; Yang, K H; Yu, H C; Cho, B H; You, H
2017-03-01
The objective of the study was to establish a right-lobe graft weight (GW) estimation formula for living donor liver transplantation (LDLT) from right-lobe graft volume without veins (GV w/o_veins ), including portal vein and hepatic vein measured by computed tomographic (CT) volumetry, and to compare its estimation accuracy with those of existing formulas. Right-lobe GW estimation formulas established with the use of graft volume with veins (GV w_veins ) sacrifice accuracy because GW measured intra-operatively excludes the weight of blood in the veins. Right-lobe GW estimation formulas have been established with the use of right-lobe GV w/o_veins , but a more accurate formula must be developed. The present study developed right-lobe GW estimation formulas based on GV w/o_veins as well as GV w_veins , using 40 cases of Korean donors: GW = 29.1 + 0.943 × GV w/o_veins (adjusted R 2 = 0.94) and GW = 74.7 + 0.773 × GV w_veins (adjusted R 2 = 0.87). The proposed GW estimation formulas were compared with existing GV w_veins - and GV w/o_veins -based models, using 43 cases additionally obtained from two medical centers for cross-validation. The GV w/o_veins -based formula developed in the present study was most preferred (absolute error = 21.5 ± 16.5 g and percentage of absolute error = 3.0 ± 2.3%). The GV w/o_veins -based formula is preferred to the GV w_veins -based formula in GW estimation. Accurate CT volumetry and alignment between planned and actual surgical cutting lines are crucial in the establishment of a better GW estimation formula. Copyright © 2016 Elsevier Inc. All rights reserved.
[Applied anatomy of small saphenous vein and its distally-based sural nerve nutrient].
Zhang, Fahui; Lin, Songqing; Zheng, Heping
2005-07-01
To investigate the origin of small saphenous vein of distally-based of sural nerve nutrient vessels flap and its clinical application. The origins of nutrient vessels of small saphenous vein and communicating branches of superficial-deep vein were observed on specimens of 30 adult cadaveric low limbs by perfusing red gelatin to dissect the artery. The nutrient vessels of small saphenous vein originated from the heel lateral artery, the terminal perforator branches of peroneal artery and intermuscular septum perforating branches of peroneal artery. There were 2 to 5 branches of such distally-based perforating branches whose diameters ranged from 0.6 to 1.0 mm. Those perforating branches included fascia branches, cutaneous branches nerve and vein nutrient branches. Those nutrient vessels formed a longitudinal vessel chain of clinical nerve shaft, vessel chain of vein side and vessel network of deep superficial fascia. The small saphenous vein had 1 to 2 communicating branches of superficial-deep vein whose diameter was 1.7+/-0.5 mm, 3.4+/-0.9 cm to the level of cusp of lateral malleolus, and converged into the fibular vein. Distally-based sural nerve, small saphenous vein, and nutrient vessels of fascia skin have the same region. The communicating branches of superficial-deep vein is 3 to 4 cm to the level of cusp lateral malleolus. These communicating branches could improve the venous drainage of the flap.
The hidden risk of deep vein thrombosis--the need for risk factor assessment: case reviews.
Race, Tara Kay; Collier, Paul E
2007-01-01
Deep vein thrombosis (DVT) is a very serious, potentially fatal, and very preventable medical condition. It is important for all patients admitted to the hospital to be screened for the risk of developing a DVT. This could be easily accomplished by performing a risk factor assessment-screening tool on all patients. It is also important to educate the medical and nursing staff on the fact that all patients are at risk for developing DVT, not just surgical patients who are often believed to be at the highest risk of DVT. The implementation of the risk factor assessment could potentially save lives and reduce the hospital costs of treating and managing the complications of DVT and venous thromboembolic disease. The cases chosen for review in this article will demonstrate many risk factors that often go overlooked in nonsurgical patients. The implementation of a risk factor assessment tool could potentially aid in the recognition and appropriate prophylaxis of those patients who are at extremely high risk for DVT. Without appropriate recognition of the risk for DVT, patients may be placed at risk for DVT and the potentially fatal and/or debilitating complications associated with the development of DVT.
Tubbs, R Shane; Watanabe, Koichi; Loukas, Marios; Cohen-Gadol, Aaron A
2014-07-01
Although the inferior petro-occipital vein has been recently used for vascular access to the cavernous sinus, few detailed descriptions of its anatomy are in the literature. We aimed to investigate the morphology and relationships of this vessel. Twelve latex-injected cadaveric heads (24 sides) were dissected to identify the inferior petro-occipital vein and anatomic details documented. The petro-occipital vein was identified on 83.3% of sides. Generally this vein united the internal carotid venous plexus to the superior jugular bulb. However, on 10% of sides, the anterior part of this vein communicated directly with the cavernous sinus, and on 15%, the posterior vein drained into the inferior petrosal sinus at its termination into the superior jugular bulb. The petro-occipital vein was separated from the overlying inferior petrosal sinus by a thin plate of bone. On 40% of sides, small venous connections were found between these two venous structures. The vein was usually larger if a nondominant transverse sinus was present. The overlying inferior petrosal sinus was smaller in diameter when an underlying inferior petro-occipital vein was present. On 20% of sides, the posterior aspect of the vein communicated with the hypoglossal canal veins. On three sides, diploic veins from the clivus drained into the inferior petro-occipital vein. The inferior petro-occipital vein is present in most humans. This primarily extracranial vessel communicates with intracranial venous sinuses and should be considered an emissary vein. Knowledge of this vessel's exact anatomy may be useful to cranial base surgeons and endovascular specialists. Copyright © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Castro-Ortega, R.; Toxqui-Quitl, C.; Solís-Villarreal, J.; Padilla-Vivanco, A.; Castro-Ramos, J.
2014-09-01
Vein patterns can be used for accessing, identifying, and authenticating purposes; which are more reliable than classical identification way. Furthermore, these patterns can be used for venipuncture in health fields to get on to veins of patients when they cannot be seen with the naked eye. In this paper, an image acquisition system is implemented in order to acquire digital images of people hands in the near infrared. The image acquisition system consists of a CCD camera and a light source with peak emission in the 880 nm. This radiation can penetrate and can be strongly absorbed by the desoxyhemoglobin that is presented in the blood of the veins. Our method of analysis is composed by several steps and the first one of all is the enhancement of acquired images which is implemented by spatial filters. After that, adaptive thresholding and mathematical morphology operations are used in order to obtain the distribution of vein patterns. The above process is focused on the people recognition through of images of their palm-dorsal distributions obtained from the near infrared light. This work has been directed for doing a comparison of two different techniques of feature extraction as moments and veincode. The classification task is achieved using Artificial Neural Networks. Two databases are used for the analysis of the performance of the algorithms. The first database used here is owned of the Hong Kong Polytechnic University and the second one is our own database.
NASA Astrophysics Data System (ADS)
Iatan, E. L.; Popescu, Gh. C.
2012-04-01
Rosia Poieni is the largest porphyry copper (±Au±Mo) deposits associated with Neogene magmatic rocks from the South Apuseni Mountains, being located approximately 8 km northeast of the town of Abrud. During a recent examination of some epithermal mineralized veins, crosscutting the porphyry mineralization from the Roşia Poieni deposit, two species of tellurides and one tellurosulfide minerals were identified. The studied samples were collected from the + 1045 m level, SW side of the open pit and are represented by epithermal veins, crosscutting the porphyry copper mineralized body. The thickness of the veins is almost 4 cm. Following reflected-polarized light microscopy to identify the ore-mineral assemblages, the polished sections were studied with a Scanning Electron Microscope (SEM) equipped with a back-scattered electron (BSE) detector to study fine-sized minerals. Quantitative compositional data were determined using a Cameca SX 50 electron microprobe (EMP). Based on optical microscopy, SEM and EMPA three mineral associations have been separated inside the epithermal vein, from the margins to the centre: 1. quartz+tennantite-tetrahedrite+goldfieldite+pyrite+sphalerite; 2. quartz+pyrite+tellurobismutite; 3. chalcopyrite+hessite+vivianite. Goldfieldite occurs in anhedral grains and it is associated with tennantite-tetrahedrite and quartz. The electron microprobe analysis gave a variable content in Te between 13.28-13.39 wt.%, 43.34 wt.% Cu, 0.1 wt. % Fe, 0.2 wt.% Zn, 14.68 wt.% As, 4.35 wt.% Sb and 24.84 wt.% S. The calculated formula for the goldfieldite is Cu11.8Te1.8(Sb,As)4S13.4. The EPM analyses on tetrahedrite-tennantite revealed a low content in Te (0.02-0.03 wt.%) and 42.23 wt.% Cu, 2.67 wt.% Fe, 7.34 wt.% Zn, 0.04 wt.% Sb, 19.28 wt.% As and 28.4 wt.% S. The calculated formula is Cu9.8(Fe,Zn)2.4(Sb,As,Te)3.8S13. The variable ratio of the Te content may reflect a variable content of Te in the hydrothermal fluids from which the tellurian tetrahedrite precipitated. Hessite lies close to the grain boundary between the calchopyrite grains, which is associated with vivianite. Electron microprobe analysis gave 57.73 wt.% Ag and 42.27 wt.% Te with calculated stoichiometric formula Ag1.9Te1.1 . Tellurobismuthite it forms irregular grains and it is associated with quartz and pyrite. Electron microprobe analysis gave 57.20 wt.% Bi and 42.80 wt.% Te with calculated stoichiometric formula Bi2.2Te2.8. Based on the mineral assemblages separated inside the ore vein and on the ratio of the Te content for the different identified tellurium bearing minerals, we can conclude that the Te content of the fluids from which they precipitated, increased from the margins to the centre of the vein. In summary, this study of specimens from Rosia Poieni porphyry copper deposit, has resulted in the recognition of some tellurium-bearing minerals, not reported by previous workers. These minerals are represented by tellurobismutite, hessite and goldfieldite and they are associated with epithermal vein mineralization (pyrite, chalcopyrite, sphalerite, tennantite-tetrahedrite, quartz, vivianite). The presence of tellurium indicates the transition between porphyry-style mineralization to epithermal vein mineralization. Acknowledgements: This work was supported by the strategic grant POSDRU/89/1.5/S58852, Project "Postdoctoral program for training scientific researches" co-financed by the European Social Found within the Sectorial Operational Program Human Resources Development 2007-2013".
Extravasation injuries: current medical and surgical treatment.
Doornaert, M; Monstrey, S; Roche, N
2013-01-01
Extravasation is a devastating complication of intravenous therapy that develops when a drug infiltrates the interstitial tissue surrounding the vein. Due to the uncertain and possibly dramatic outcome, early recognition and adequate treatment with the aid of a standardized protocol are needed. A pubmed literature search was conducted and all relevant articles were reviewed for the development of an extravasation treatment protocol. An overview of current treatment guidelines and clinical experience is provided. The extravasation treatment protocol was implied during 1 year in this university hospital with satisfactory outcome. Treatment starts with prevention. In case of an established extravasation injury, early recognition, assessment of severity, and treatment with medical and/or surgical therapies are recommended.
Augmented reality based real-time subcutaneous vein imaging system
Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian
2016-01-01
A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed. PMID:27446690
Augmented reality based real-time subcutaneous vein imaging system.
Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian
2016-07-01
A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed.
Deep vein thrombosis in hospitalized patients: a review of evidence-based guidelines for prevention.
Kehl-Pruett, Wendy
2006-01-01
Deep vein thrombosis affects many hospitalized patients because of decreased activity and therapeutic equipment. This article reviews known risk factors for developing deep vein thrombosis, current prevention methods, and current evidence-based guidelines in order to raise nurses' awareness of early prevention methods in all hospitalized patients. Early prophylaxis can reduce patient risk of deep vein thrombosis and its complications.
Mauk, Jeffrey L.; Skinner, Erin G; Fyfe, Sarah J; Menzies, Andrew H; Lowers, Heather A.; Koenig, Alan E.
2016-01-01
The Waihi district in the Hauraki Goldfield of New Zealand contains adularia-sericite epithermal gold-silver veins that have produced more than 7.7 Moz gold. The outermost veins of the district (Martha, Favona, Moonlight, and Cowshed) contain abundant colloform, cherty, and black quartz fill textures, with minor crustiform and massive quartz. The central veins (Amaranth, Trio, and Union) contain predominantly massive and crustiform textures, and these veins are also commonly coarser grained than outermost veins. Pyrite, sphalerite, galena, chalcopyrite, electrum, and acanthite occur in both outermost and central veins; base metal sulfide minerals typically increase in abundance in deeper samples. Antimony-, arsenic-, and selenium-bearing minerals are most abundant in the Favona and Moonlight veins, whereas base metal sulfide minerals are more abundant in the central veins at Correnso. Throughout the Waihi vein system, electrum is by far the most widespread, abundant, and significant gold-bearing mineral, but LA-ICP-MS analyses show that arsenian pyrite also contains some gold. Mineralogical and textural data are consistent with the central veins forming at a deeper structural level, or from hydrothermal fluids with different chemistry, or both.
Corona Phase Molecular Recognition (CoPhMoRe) to Enable New Nanosensor Interfaces
NASA Astrophysics Data System (ADS)
Strano, Michael
2015-03-01
Our lab at MIT has been interested in how the 1D and 2D electronic structures of carbon nanotubes and graphene respectively can be utilized to advance new concepts in molecular detection. We introduce CoPhMoRe or corona phase molecular recognition as a method of discovering synthetic antibodies, or nanotube-templated recognition sites from a heteropolymer library. We show that certain synthetic heteropolymers, once constrained onto a single-walled carbon nanotube by chemical adsorption, also form a new corona phase that exhibits highly selective recognition for specific molecules. To prove the generality of this phenomenon, we report three examples of heteropolymers-nanotube recognition complexes for riboflavin, L-thyroxine and estradiol. The platform opens new opportunities to create synthetic recognition sites for molecular detection. We have also extended this molecular recognition technique to neurotransmitters, producing the first fluorescent sensor for dopamine. Another area of advancement in biosensor development is the use of near infrared fluorescent carbon nanotube sensors for in-vivo detection. Here, we show that PEG-ligated d(AAAT)7 DNA wrapped SWNT are selective for nitric oxide, a vasodilator of blood vessels, and can be tail vein injected into mice and localized within the viable mouse liver. We use an SJL mouse model to study liver inflammation in vivo using the spatially and spectrally resolved nIR signature of the localized SWNT sensors.
Finger-Vein Verification Based on Multi-Features Fusion
Qin, Huafeng; Qin, Lan; Xue, Lian; He, Xiping; Yu, Chengbo; Liang, Xinyuan
2013-01-01
This paper presents a new scheme to improve the performance of finger-vein identification systems. Firstly, a vein pattern extraction method to extract the finger-vein shape and orientation features is proposed. Secondly, to accommodate the potential local and global variations at the same time, a region-based matching scheme is investigated by employing the Scale Invariant Feature Transform (SIFT) matching method. Finally, the finger-vein shape, orientation and SIFT features are combined to further enhance the performance. The experimental results on databases of 426 and 170 fingers demonstrate the consistent superiority of the proposed approach. PMID:24196433
Design and implementation of a contactless multiple hand feature acquisition system
NASA Astrophysics Data System (ADS)
Zhao, Qiushi; Bu, Wei; Wu, Xiangqian; Zhang, David
2012-06-01
In this work, an integrated contactless multiple hand feature acquisition system is designed. The system can capture palmprint, palm vein, and palm dorsal vein images simultaneously. Moreover, the images are captured in a contactless manner, that is, users need not to touch any part of the device when capturing. Palmprint is imaged under visible illumination while palm vein and palm dorsal vein are imaged under near infrared (NIR) illumination. The capturing is controlled by computer and the whole process is less than 1 second, which is sufficient for online biometric systems. Based on this device, this paper also implements a contactless hand-based multimodal biometric system. Palmprint, palm vein, palm dorsal vein, finger vein, and hand geometry features are extracted from the captured images. After similarity measure, the matching scores are fused using weighted sum fusion rule. Experimental results show that although the verification accuracy of each uni-modality is not as high as that of state-of-the-art, the fusion result is superior to most of the existing hand-based biometric systems. This result indicates that the proposed device is competent in the application of contactless multimodal hand-based biometrics.
phenoVein—A Tool for Leaf Vein Segmentation and Analysis1[OPEN
Pflugfelder, Daniel; Huber, Gregor; Scharr, Hanno; Hülskamp, Martin; Koornneef, Maarten; Jahnke, Siegfried
2015-01-01
Precise measurements of leaf vein traits are an important aspect of plant phenotyping for ecological and genetic research. Here, we present a powerful and user-friendly image analysis tool named phenoVein. It is dedicated to automated segmenting and analyzing of leaf veins in images acquired with different imaging modalities (microscope, macrophotography, etc.), including options for comfortable manual correction. Advanced image filtering emphasizes veins from the background and compensates for local brightness inhomogeneities. The most important traits being calculated are total vein length, vein density, piecewise vein lengths and widths, areole area, and skeleton graph statistics, like the number of branching or ending points. For the determination of vein widths, a model-based vein edge estimation approach has been implemented. Validation was performed for the measurement of vein length, vein width, and vein density of Arabidopsis (Arabidopsis thaliana), proving the reliability of phenoVein. We demonstrate the power of phenoVein on a set of previously described vein structure mutants of Arabidopsis (hemivenata, ondulata3, and asymmetric leaves2-101) compared with wild-type accessions Columbia-0 and Landsberg erecta-0. phenoVein is freely available as open-source software. PMID:26468519
Edwards, G.; Henshaw, M.; Miller, M.; Weston, A. H.
1991-01-01
1. The ability of several K-channel openers to inhibit KCl-induced contractions of rat bladder detrusor and spontaneous mechanical activity in rat portal vein was examined. 2. Lemakalim, pinacidil, Ro 31-6930, RP 49356, P1060 and S 0121 dose-dependently relaxed rat detrusor, precontracted with 20 mM KCl. With the exception of pinacidil, concentrations of these agents below 30 microM did not inhibit 80 mM KCl-included contractions. Pinacidil (10 microM) produced a small, but significant (P < 0.05) relaxation of 80 mM KCl-induced mechanical activity. Minoxidil sulphate and BRL 38226 produced some relaxation of 20 mM but not 80 mM KCl-induced contractions. 3. Glibenclamide (0.3-3 microM) antagonized the relaxant effects of lemakalim, pinacidil, Ro 31-6930, RP 49356, P1060 and S 0121 in a competitive manner (pA2 values 6.3-6.6). The effects of minoxidil sulphate and BRL 38226 were fully antagonized by 3 microM glibenclamide. 4. Lemakalim, pinacidil, S 0121, BRL 38226 and minoxidil sulphate were each approximately 8 times more potent as inhibitors of the spontaneous contractions of rat portal vein than KCl-induced contractions of the rat detrusor. Minoxidil sulphate was approximately 30 times more potent in the rat portal vein than in the bladder. This may indicate that either minoxidil sulphate is acting at different recognition sites in these two tissues, or that this compound has an additional mechanism of action in the portal vein. 5. With the exception of minoxidil sulphate, all the compounds tested stimulated 86Rb efflux and 42K efflux from preloaded rat detrusor strips.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1364839
[Anatomical strategies of Henle trunk in laparoscopic right hemi-colectomy for right colon cancer].
Feng, Bo; Yan, Xialin; Zhang, Sen; Xue, Pei; He, Zirui; Zheng, Minhua
2017-06-25
The advancement of laparoscopic surgery serves as a trigger for better understanding of the vascular structure at the inferior border of the pancreas, especially Henle trunk. Henle trunk was first found as convergence to superior mesenteric vein (SMV) conjoined by sub-right colon vein (SRCV) and right gastroepiploic vein (RGEV), but decades later, anterior superior pancreatic duodenal vein (ASPDV) was described as another conjoint vein of Henle trunk. These tributaries are the basic elements of Henle trunk in early years' study. A proper surgical procedure for Henle trunk can significantly reduce the complications of radical right hemi-colectomy (Japanese D3 resection and European complete mesocolic excision, CME). There are four variations of Henle trunk according to the colic venous tributaries that consists the anatomic variations in transverse colon posterior space(TRCPS). These variations are like "fingerprint and pattern" of CME. The recognition and extension of the TRCS is the key to the dissection of Henle trunk in laparoscopic right hemi-colectomy. Our medical center proposed four feasible approaches for extension:(1) hybrid medial approach; (2) completely medial approach; (3)completely medial access by "page-turning" approach; (4) completely medial approach along RCV. Mostly, RCV ended in Henle trunk, and completely medial approach along RCV is efficient to identify the Henle trunk in CME. We suggest dissecting the inferior margin of pancreas along SMV in a bottom-to-top fashion, followed by the dissection of middle colic vessels to reveal the root of Henle trunk. And it's better to dissect Henle trunk by branch rather than at its root for safety. Here, we describe the anatomic characters of Henles trunk, the surgical approach and strategies of Henle trunk in laparoscopic surgery.
A clear map of the lower cranial nerves at the superior carotid triangle.
Cavalcanti, Daniel D; Garcia-Gonzalez, Ulises; Agrawal, Abhishek; Tavares, Paulo L M S; Spetzler, Robert F; Preul, Mark C
2010-07-01
The lower cranial nerves must be identified to avoid iatrogenic injury during skull base and high cervical approaches. Prompt recognition of these structures using basic landmarks could reduce surgical time and morbidity. The anterior triangle of the neck was dissected in 30 cadaveric head sides. The most superficial segments of the glossopharyngeal, vagus and its superior laryngeal nerves, accessory, and hypoglossal nerves were exposed and designated into smaller anatomic triangles. The midpoint of each nerve segment inside the triangles was correlated to the angle of the mandible (AM), mastoid tip (MT), and bifurcation of the common carotid artery. A triangle bounded by the styloglossus muscle, external carotid artery, and facial artery housed the glossopharyngeal nerve. This nerve segment was 0.06 ± 0.71 cm posterior to the AM and 2.50 ± 0.59 cm inferior to the MT. The vagus nerve ran inside the carotid sheath posterior to internal carotid artery and common carotid artery bifurcation in 48.3% of specimens. A triangle formed by the posterior belly of digastric muscle, sternocleidomastoid muscle, and internal jugular vein housed the accessory nerve, 1.90 ± 0.60 cm posterior to the AM and 2.30 ± 0.57 cm inferior to the MT. A triangle outlined by the posterior belly of digastric muscle, internal jugular vein, and common facial vein housed the hypoglossal nerve, which was 0.82 ± 0.84 cm posterior to the AM and 3.64 ± 0.70 cm inferior to the MT. Comprehensible landmarks can be defined to help expose the lower cranial nerves to avoid injury to this complex region. Copyright © 2010 Elsevier Inc. All rights reserved.
O'Brien, Alanna; Redley, Bernice; Wood, Beverley; Botti, Mari; Hutchinson, Anastasia F
2018-03-01
To develop and test a clinical tool to guide nurses' assessment of postoperative patients for Deep Vein Thrombosis. Preventing venous thromboembolism in hospitalised patients is an international patient safety priority. Despite high-level evidence for optimal venous thromboembolism prophylaxis, implementation is inconsistent and the incidence of Deep Vein Thrombosis remains high. A two-stage sequential multi-method design was used. In stage 1, the STOPDVTs tool was developed using a review of the literature and focus groups with local clinical experts. Stage 2 involved pilot testing the tool with 38 surgical nurses who conducted repeated assessments on a prospective sample of 50 postoperative orthopaedic patients. Stage 1: The focus group members who were members of the nursing leadership team agreed on eight local and systemic signs and symptoms that should be included in a nursing patient assessment tool for early Deep Vein Thrombosis. Local symptoms were pain in the limbs, calf swelling and tightness, changes in the affected limb's skin temperature. Systemic signs included in the tool were as follows: increased shortness of breath, increased respiratory and heart rates, and decreased oxygen saturation. Stage 2: The STOPDVTs tool had acceptable face and content validity, the agreement between the expert nurse and surgical nurses on assessments of individual signs and symptoms varied between 44%-94%. Surgical nurses were less likely than the expert nurse to identify signs indicative of Deep Vein Thrombosis. Despite finding the STOPDVTs clinical assessment tool was a useful guide for nursing assessment, surgical nurses often underestimated the potential importance of clinical signs. The findings reveal a gap in nursing knowledge and skill in assessing for Deep Vein Thrombosis in postoperative orthopaedic patients. This study identified a possible risk to patient safety related to under-recognition of the signs and symptoms of possible Deep Vein Thrombosis (DVT) in postoperative orthopaedic patients. The findings demonstrate the feasibility of developing and implementing a protocol for consistent screening by nurses for possible DVT in the postoperative period. © 2018 John Wiley & Sons Ltd.
Danilenko-Dixon, D R; Heit, J A; Silverstein, M D; Yawn, B P; Petterson, T M; Lohse, C M; Melton, L J
2001-01-01
We sought to determine risk factors for deep vein thrombosis and pulmonary embolism during pregnancy or post partum. We performed a population-based case-control study. All Olmsted County, Minnesota, residents with a first lifetime deep vein thrombosis or pulmonary embolism during pregnancy or post partum from 1966 to 1990 were identified (N = 90). Where possible, a resident without deep vein thrombosis or pulmonary embolism was matched to each patient by date of the first live birth after the patient's child. The medical records of all remaining patients and all control subjects were reviewed for >25 baseline characteristics, which were tested as risk factors for deep vein thrombosis or pulmonary embolism. In multivariate analysis smoking (odds ratio, 2.4) and prior superficial vein thrombosis (odds ratio, 9.4) were independent risk factors for deep vein thrombosis or pulmonary thrombosis during pregnancy or post partum. Venous thromboembolism prophylaxis may be warranted for pregnant women with prior superficial vein thrombosis. Smoking cessation should be recommended, especially during pregnancy and the postpartum period.
Management Strategy for Patients With Chronic Subclavian Vein Thrombosis.
Keir, Graham; Marshall, M Blair
2017-02-01
We performed a systematic review to determine best practice for the management of patients with chronic or subacute subclavian vein thrombosis. This condition is best managed with surgical excision of the first rib followed by long-term anticoagulation. Interventional techniques aimed at restoring patency are ineffective beyond 2 weeks postthrombosis. Additional therapeutic options should be made based on the severity of symptoms as well as vein status. Patients with milder symptoms are given decompression surgery followed by anticoagulation whereas patients with more severe symptoms are considered for either a jugular vein transposition or saphenous patch based on the vein characteristics. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Gillet, J L; Lausecker, M; Sica, M; Guedes, J M; Allaert, F A
2014-10-01
To assess the deep vein thrombosis risk of the treatment of the small saphenous veins depending on the anatomical pattern of the veins. A multicenter, prospective and controlled study was carried out in which small saphenous vein trunks were treated with ultrasound-guided foam sclerotherapy. The anatomical pattern (saphenopopliteal junction, perforators) was assessed by Duplex ultrasound before the treatment. All patients were systematically checked by Duplex ultrasound 8 to 30 days after the procedure to identify a potential deep vein thrombosis. Three hundred and thirty-one small saphenous veins were treated in 22 phlebology clinics. No proximal deep vein thrombosis occurred. Two (0.6%) medial gastrocnemius veins thrombosis occurred in symptomatic patients. Five medial gastrocnemius veins thrombosis and four cases of extension of the small saphenous vein sclerosis into the popliteal vein, which all occurred when the small saphenous vein connected directly into the popliteal vein, were identified by systematic Duplex ultrasound examination in asymptomatic patients. Medial gastrocnemius veins thrombosis were more frequent (p = 0.02) in patients with medial gastrocnemius veins perforator. A common outlet or channel between the small saphenous vein and the medial gastrocnemius veins did not increase the risk of deep vein thrombosis. Deep vein thrombosis after foam sclerotherapy of the small saphenous vein are very rare. Only 0.6% medial gastrocnemius veins thrombosis occurred in symptomatic patients. However, the anatomical pattern of the small saphenous vein should be taken into account and patients with medial gastrocnemius veins perforators and the small saphenous vein connected directly into the popliteal vein should be checked by Duplex ultrasound one or two weeks after the procedure. Recommendations based on our everyday practice and the findings of this study are suggested to prevent and treat deep vein thrombosis. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Finger vein identification using fuzzy-based k-nearest centroid neighbor classifier
NASA Astrophysics Data System (ADS)
Rosdi, Bakhtiar Affendi; Jaafar, Haryati; Ramli, Dzati Athiar
2015-02-01
In this paper, a new approach for personal identification using finger vein image is presented. Finger vein is an emerging type of biometrics that attracts attention of researchers in biometrics area. As compared to other biometric traits such as face, fingerprint and iris, finger vein is more secured and hard to counterfeit since the features are inside the human body. So far, most of the researchers focus on how to extract robust features from the captured vein images. Not much research was conducted on the classification of the extracted features. In this paper, a new classifier called fuzzy-based k-nearest centroid neighbor (FkNCN) is applied to classify the finger vein image. The proposed FkNCN employs a surrounding rule to obtain the k-nearest centroid neighbors based on the spatial distributions of the training images and their distance to the test image. Then, the fuzzy membership function is utilized to assign the test image to the class which is frequently represented by the k-nearest centroid neighbors. Experimental evaluation using our own database which was collected from 492 fingers shows that the proposed FkNCN has better performance than the k-nearest neighbor, k-nearest-centroid neighbor and fuzzy-based-k-nearest neighbor classifiers. This shows that the proposed classifier is able to identify the finger vein image effectively.
Palm Vein Verification Using Multiple Features and Locality Preserving Projections
Bu, Wei; Wu, Xiangqian; Zhao, Qiushi
2014-01-01
Biometrics is defined as identifying people by their physiological characteristic, such as iris pattern, fingerprint, and face, or by some aspects of their behavior, such as voice, signature, and gesture. Considerable attention has been drawn on these issues during the last several decades. And many biometric systems for commercial applications have been successfully developed. Recently, the vein pattern biometric becomes increasingly attractive for its uniqueness, stability, and noninvasiveness. A vein pattern is the physical distribution structure of the blood vessels underneath a person's skin. The palm vein pattern is very ganglion and it shows a huge number of vessels. The attitude of the palm vein vessels stays in the same location for the whole life and its pattern is definitely unique. In our work, the matching filter method is proposed for the palm vein image enhancement. New palm vein features extraction methods, global feature extracted based on wavelet coefficients and locality preserving projections (WLPP), and local feature based on local binary pattern variance and locality preserving projections (LBPV_LPP) have been proposed. Finally, the nearest neighbour matching method has been proposed that verified the test palm vein images. The experimental result shows that the EER to the proposed method is 0.1378%. PMID:24693230
Palm vein verification using multiple features and locality preserving projections.
Al-Juboori, Ali Mohsin; Bu, Wei; Wu, Xiangqian; Zhao, Qiushi
2014-01-01
Biometrics is defined as identifying people by their physiological characteristic, such as iris pattern, fingerprint, and face, or by some aspects of their behavior, such as voice, signature, and gesture. Considerable attention has been drawn on these issues during the last several decades. And many biometric systems for commercial applications have been successfully developed. Recently, the vein pattern biometric becomes increasingly attractive for its uniqueness, stability, and noninvasiveness. A vein pattern is the physical distribution structure of the blood vessels underneath a person's skin. The palm vein pattern is very ganglion and it shows a huge number of vessels. The attitude of the palm vein vessels stays in the same location for the whole life and its pattern is definitely unique. In our work, the matching filter method is proposed for the palm vein image enhancement. New palm vein features extraction methods, global feature extracted based on wavelet coefficients and locality preserving projections (WLPP), and local feature based on local binary pattern variance and locality preserving projections (LBPV_LPP) have been proposed. Finally, the nearest neighbour matching method has been proposed that verified the test palm vein images. The experimental result shows that the EER to the proposed method is 0.1378%.
Klein, T.L.
2004-01-01
Metal deposits spatially associated with the Cretaceous Boulder and Idaho batholiths of southwestern Montana and southern and central Idaho have been exploited since the early 1860s. Au was first discovered in placer deposits; exploitation of vein deposits in bedrock soon followed. In 1865, high-grade Ag vein deposits were discovered and remained economically important until the 1890s. Early high-grade deposits of Au, Ag and Pb were found in the weathered portions of the veins systems. As mining progressed to deeper levels, Ag and Pb grades diminished. Exploration for and development of these vein deposits in this area have continued until the present. A majority of these base- and precious-metal vein deposits are classified as polymetallic veins (PMV) and polymetallic carbonate-replacement (PMR) deposits in this compilation. Porphyry Cu and Mo, epithermal (Au, Ag, Hg and Sb), base- and precious-metal and W skarn, W vein, and U and Th vein deposits are also common in this area. The world-class Butte Cu porphyry and the Butte high-sulfidation Cu vein deposits are in this study area. PMV and PMR deposits are the most numerous in the region and constitute about 85% of the deposit records compiled. Several types of syngenetic/diagenetic sulfide mineral deposits in rocks of the Belt Supergroup or their equivalents are common in the region and they have been the source of a substantial metal production over the last century. These syngenetic deposits and their metamorphosed/structurally remobilized equivalents were not included in this database; therefore, deposits in the Idaho portion of the Coeur d'Alene district and the Idaho Cobalt belt, for example, have not been included because many of them are believed to be of this type.
Pancreas Transplant Venous Thrombosis: Role of Endovascular Interventions for Graft Salvage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stockland, Andrew H.; Willingham, Darrin L.; Paz-Fumagalli, Ricardo
2009-03-15
Venous thrombosis of pancreas transplant allografts often leads to graft loss. We evaluated the efficacy of emergent endovascular techniques to salvage thrombosed pancreatic allografts in a series of six patients. Of the 76 pancreas transplants performed between 2002 and 2006, six patients were diagnosed with venous thrombosis on MRI between 2 and 28 days posttransplant (mean, 9 days). Five patients were systemic-enteric (donor portal vein anastomosis to recipient iliac vein) and one patient was portal-enteric (donor portal vein anastomosis to recipient superior mesenteric vein). Conventional venography confirmed the diagnosis of venous thrombosis in all patients. One patient was treated withmore » catheter-directed venous thrombolysis and balloon thrombectomy. Another patient was treated with rheolytic thrombectomy alone. The remaining four patients were treated with a combination of these mechanical and thrombolytic techniques. Completion venography revealed >50% clot reduction and resumption of venous drainage in all patients. One patient required additional intervention 16 days later for recurrent thrombosis. Two patients required metal stent placement for anastomotic stenoses or kinks. One patient required pancreatectomy 36 h after attempted salvage secondary to a major hemorrhage and graft necrosis. Two patients recovered pancreatic function initially but lost graft function at 8 and 14 months, respectively, from severe chronic rejection. Patient survival was 100%, long-term graft survival was 50%, rethrombosis rate was 16.6%, and graft loss from rejection was 33%. In conclusion, early recognition and treatment of venous thrombosis after pancreas transplantation has acceptable morbidity and no mortality using short-term endovascular pharmacomechanical therapy.« less
A new design concept for knitted external vein-graft support mesh.
Singh, Charanpreet; Wang, Xungai
2015-08-01
Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh. Copyright © 2015 Elsevier Ltd. All rights reserved.
Near-infrared image formation and processing for the extraction of hand veins
NASA Astrophysics Data System (ADS)
Bouzida, Nabila; Hakim Bendada, Abdel; Maldague, Xavier P.
2010-10-01
The main objective of this work is to extract the hand vein network using a non-invasive technique in the near-infrared region (NIR). The visualization of the veins is based on a relevant feature of the blood in relation with certain wavelengths of the electromagnetic spectrum. In the present paper, we first introduce the image formation in the NIR spectral band. Then, the acquisition system will be presented as well as the method used for the image processing in order to extract the vein signature. Extractions of this pattern on the finger, on the wrist and on the dorsal hand are achieved after exposing the hand to an optical stimulation by reflection or transmission of light. We present meaningful results of the extracted vein pattern demonstrating the utility of the method for a clinical application like the diagnosis of vein disease, of primitive varicose vein and also for applications in vein biometrics.
Wu, Min; Fu, Xianming; Ji, Ying; Ding, Wanhai; Deng, Dali; Wang, Yehan; Jiang, Xiaofeng; Niu, Chaoshi
2018-05-01
Microvascular decompression of the trigeminal nerve is the most effective treatment for trigeminal neuralgia. However, when encountering classical trigeminal neuralgia caused by venous compression, the procedure becomes much more difficult, and failure or recurrence because of incomplete decompression may become frequent. This study aimed to investigate the anatomic variation of the culprit veins and discuss the surgical strategy for different types. We performed a retrospective analysis of 64 consecutive cases in whom veins were considered as responsible vessels alone or combined with other adjacent arteries. The study classified culprit veins according to operative anatomy and designed personalized approaches and decompression management according to different forms of compressive veins. Curative effects were assessed by the Barrow Neurological Institute (BNI) pain intensity score and BNI facial numbness score. The most commonly encountered veins were the superior petrosal venous complex (SPVC), which was artificially divided into 4 types according to both venous tributary distribution and empty point site. We synthetically considered these factors and selected an approach to expose the trigeminal root entry zone, including the suprafloccular transhorizontal fissure approach and infratentorial supracerebellar approach. The methods of decompression consist of interposing and transposing by using Teflon, and sometimes with the aid of medical adhesive. Nerve combing (NC) of the trigeminal root was conducted in situations of extremely difficult neurovascular compression, instead of sacrificing veins. Pain completely disappeared in 51 patients, and the excellent outcome rate was 79.7%. There were 13 patients with pain relief treated with reoperation. Postoperative complications included 10 cases of facial numbness, 1 case of intracranial infection, and 1 case of high-frequency hearing loss. The accuracy recognition of anatomic variation of the SPVC is crucial for the management of classical trigeminal neuralgia caused by venous compression. Selecting an appropriate approach and using reasonable decompression methods can bring complete postoperative pain relief for most cases. NC can be an alternative choice for extremely difficult cases, but it could lead to facial numbness more frequently. Copyright © 2018 Elsevier Inc. All rights reserved.
Price, Charles A; Knox, Sarah-Jane C; Brodribb, Tim J
2013-01-01
Models that predict the form of hierarchical branching networks typically invoke optimization based on biomechanical similitude, the minimization of impedance to fluid flow, or construction costs. Unfortunately, due to the small size and high number of vein segments found in real biological networks, complete descriptions of networks needed to evaluate such models are rare. To help address this we report results from the analysis of the branching geometry of 349 leaf vein networks comprising over 1.5 million individual vein segments. In addition to measuring the diameters of individual veins before and after vein bifurcations, we also assign vein orders using the Horton-Strahler ordering algorithm adopted from the study of river networks. Our results demonstrate that across all leaves, both radius tapering and the ratio of daughter to parent branch areas for leaf veins are in strong agreement with the expectation from Murray's law. However, as veins become larger, area ratios shift systematically toward values expected under area-preserving branching. Our work supports the idea that leaf vein networks differentiate roles of leaf support and hydraulic supply between hierarchical orders.
Geleto, Gemechu; Getnet, Wondim; Tewelde, Tsegaye
2016-05-01
Mean portal vein diameter is considered as the best indicator for portal hypertension. However, the cutoff point differs from study to study (above 10-15 mm) despite the existence of normal mean portal vein diameter between 10-15 mm in different settings.This implies the existence of limited evidence on normal portal vein diameter for all populations in all countries prior to setting the cutoff points. Therefore, the aim of this study was sonographic assessment of normal mean portal vein diameter among patients referred to The Department of Radiology in Jimma University Hospital. A facility based cross-sectional study was conducted from November to December 2014 at Jimma University Hospital on a total of 195 clients. Data about portal vein diameter for eligible clients were collected by radiologists using Sonography. Data were edited manually, entered and analyzed using SPSS version 16. Data were collected from a total of 195 participants. Among these, 121(62.1%) were males and the median age of the participants was 35 years. The study revealed a normal mean portal vein diameter of 10.6 mm ±1.8 SD with a respirophasic variation of 25.6%. Likewise, the normal mean portal vein diameter seemed to have varied significantly by age and sex. The study revealed a normal mean portal vein diameter ranging below 13 mm. Hence, decisions made in clinical settings should base on these findings. Besides, there is a need for large scale study to determine portal vein diameter variation by age and sex, controlling other confounders.
Rare-earth Nanoparticle-induced Cytotoxicity on Spatial Cognition Memory of Mouse Brain.
Lin, Cai-Hou; Liu, Gui-Fen; Chen, Jing; Chen, Yan; Lin, Ru-Hui; He, Hong-Xing; Chen, Jian-Ping
2017-11-20
Luminescent rare-earth-based nanoparticles have been increasingly used in nanomedicine due to their excellent physicochemical properties, such as biomedical imaging agents, drug carriers, and biomarkers. However, biological safety of the rare-earth-based nanomedicine is of great significance for future development in practical applications. In particular, biological effects of rare-earth nanoparticles on human's central nervous system are still unclear. This study aimed to investigate the potential toxicity of rare-earth nanoparticles in nervous system function in the case of continuous exposure. Adult ICR mice were randomly divided into seven groups, including control group (receiving 0.9% normal saline) and six experimental groups (10 mice in each group). Luminescent rare-earth-based nanoparticles were synthesized by a reported co-precipitation method. Two different sizes of the nanoparticles were obtained, and then exposed to ICR mice through caudal vein injection at 0.5, 1.0, and 1.5 mg/kg body weight in each day for 7 days. Next, a Morris water maze test was employed to evaluate impaired behaviors of their spatial recognition memory. Finally, histopathological examination was implemented to study how the nanoparticles can affect the brain tissue of the ICR mice. Two different sizes of rare-earth nanoparticles have been successfully obtained, and their physical properties including luminescence spectra and nanoparticle sizes have been characterized. In these experiments, the rare-earth nanoparticles were taken up in the mouse liver using the magnetic resonance imaging characterization. Most importantly, the experimental results of the Morris water maze tests and histopathological analysis clearly showed that rare-earth nanoparticles could induce toxicity on mouse brain and impair the behaviors of spatial recognition memory. Finally, the mechanism of adenosine triphosphate quenching by the rare-earth nanoparticles was provided to illustrate the toxicity on the mouse brain. This study suggested that long-term exposure of high-dose bare rare-earth nanoparticles caused an obvious damage on the spatial recognition memory in the mice.
Sack, Lawren; Caringella, Marissa; Scoffoni, Christine; Mason, Chase; Rawls, Michael; Markesteijn, Lars; Poorter, Lourens
2014-10-01
Leaf vein length per unit leaf area (VLA; also known as vein density) is an important determinant of water and sugar transport, photosynthetic function, and biomechanical support. A range of software methods are in use to visualize and measure vein systems in cleared leaf images; typically, users locate veins by digital tracing, but recent articles introduced software by which users can locate veins using thresholding (i.e. based on the contrasting of veins in the image). Based on the use of this method, a recent study argued against the existence of a fixed VLA value for a given leaf, proposing instead that VLA increases with the magnification of the image due to intrinsic properties of the vein system, and recommended that future measurements use a common, low image magnification for measurements. We tested these claims with new measurements using the software LEAFGUI in comparison with digital tracing using ImageJ software. We found that the apparent increase of VLA with magnification was an artifact of (1) using low-quality and low-magnification images and (2) errors in the algorithms of LEAFGUI. Given the use of images of sufficient magnification and quality, and analysis with error-free software, the VLA can be measured precisely and accurately. These findings point to important principles for improving the quantity and quality of important information gathered from leaf vein systems. © 2014 American Society of Plant Biologists. All Rights Reserved.
Kawanaka, Hirofumi; Akahoshi, Tomohiko; Nagao, Yoshihiro; Kinjo, Nao; Yoshida, Daisuke; Matsumoto, Yoshihiro; Harimoto, Norifumi; Itoh, Shinji; Yoshizumi, Tomoharu; Maehara, Yoshihiko
2018-01-01
Laparoscopic gastric devascularization(Lap GDS) and splenectomy (SPL) for gastric varices is technically challenging because of highly developed collateral vessels and bleeding tendency. We investigated the feasibility of customization of Lap GDS and SPL based on CT vascular anatomy. We analyzed 61 cirrhotic patients with gastric varices who underwent Lap GDS and SPL between 2006 and 2014. Lap GDS was customized according to the afferent feeding veins (left gastric vein (LGV) and/or posterior gastric vein (PGV)/short gastric vein (SGV)) and efferent drainage veins (gastrorenal shunt and/or gastrophrenic shunt, or numerous retroperitoneal veins) based on CT imaging. Thirty-four patients with efferent drainage veins suitable for balloon-occluded retrograde transvenous obliteration (B-RTO) underwent B-RTO instead of surgical GDS, with subsequent Lap SPL. Among 27 patients with gastric varices unsuitable for B-RTO, 15 patients with PGV/SGV underwent Lap GDS of the greater curvature and SPL, and 12 patients with LGV or LGV/PGV/SGV underwent Lap GDS of the greater and lesser curvature and SPL. The mean operation time was 294 min and mean blood loss was 198 g. There was no mortality or severe morbidity. Gastric varices were eradicated in all 61 patients, with no bleeding or recurrence during a mean follow-up of 55.9 months. The cumulative 3-, 5-, and 7-year survival rates were 92, 82, and 64%, respectively. Lap GDS and SPL customized based on CT vascular anatomy is a safe and effective procedure for treating gastric varices.
Cuddy, Karl; Saadat, Nariman; Khatib, Baber; Patel, Ashish
2018-01-01
Lemierre syndrome is an uncommon condition in which internal jugular vein thrombosis presents after recent oropharyngeal infection. Frequently, this is accompanied by septic emboli. This report outlines a variant of this disease process, with septic thrombophlebitis of the neck associated with a necrotizing skin infection of the lower lip and chin. A 25-year-old man with lower lip and chin swelling, initially managed with intravenous antibiotics, progressed to the development of a left facial vein thrombus, septic emboli to the lungs, and a necrotizing lower lip and chin infection that was managed with debridement, thrombectomy, and prolonged hemodynamic and pulmonary support. A necrotizing skin infection with thrombus of the jugular system and septic emboli is a very rare variant of Lemierre syndrome. Early recognition of an infection with septic emboli and/or necrotizing pathobiological findings allows for prompt antibiotic and surgical therapy, minimizing the mortality of these potentially lethal infections. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Jagadish, Mayuri; McNally, Michael M; Heidel, R Eric; Teffeteller, Susan; Arnold, Joshua D; Freeman, Michael; Stevens, Scott L; Grandas, Oscar H; Goldman, Mitchell H
2016-08-01
Diabetic foot ulcers (DFUs) are a major burden on the health-care system. The purpose of this study is to investigate factors affecting the healing rate of DFU in a university wound care center. Records of DFU patients treated between July 2013 and February 2015 were reviewed. Demographics, comorbidities, wound characteristics, and treatment modalities including offloading, hyperbaric oxygen treatment, total contact casting, and bioengineered skin were investigated. All patients underwent weekly debridement regardless of treatment modality. A total of 114 patients ages 18 to 98 comprised the study population. Total contact casting was the only treatment associated with increased healing (P = 0.02). Smoking (P = 0.004) and deep vein thrombosis history (P = 0.001) significantly decreased the likelihood of wound healing. Patients with past vascular event trended toward longer healing times (P = 0.07). Total contact casting in combination with weekly wound debridement showed benefit in DFU wound healing, whereas patients with a history of deep vein thrombosis and smoking were less likely to heal.
Restrepo, Paula; Jameson, Deborah L; Carroll, Diane L
2015-01-01
Deep vein thrombosis remains a source of adverse outcomes in surgical patients. Deep vein thrombosis is preventable with prophylactic intervention. The success of noninvasive mechanical modalities for prophylaxis relies on compliance with correct application. The goals of this project were to create a guideline that reflected current evidence and expert thinking about mechanical modalities use, assess compliance with mechanical modalities, and develop strategies to disseminate an evidence-based guideline for deep vein thrombosis prophylaxis.
Anatomical variations of the right hepatic veins and their relevance to surgery.
Hribernik, Marija; de Cecchis, Lucio; Trotovsek, Blaz; Gadzijev, Eldar M; Ravnik, Dean
2003-01-01
In a morphological study of the right hepatic veins anatomical characteristics of surgical importance were looked for. 110 cadaveric human livers were prepared by the corrosion casts method. The confluence patterns of the superior right hepatic vein, the hepatocaval confluence, the accessory right hepatic veins and the anastomoses between hepatic veins in the right hemiliver were examined. Four types of the superior right hepatic vein, based on the length of its trunk and the confluence pattern of its main tributaries were determined and their frequency was calculated. Type I was found in 20%, type II in 40%, type III in 25% and type IV in 15%. Accessory right hepatic veins with a minimal caliber of 0.4 cm, which were always present in type IV, were also found in other types, all together in 27% of the casts. The tributary-free part of the superior right hepatic vein at hepatocaval confluence was longer than 1 cm in 77%. In the right hemiliver 109 anastomoses were found in 29/110 liver casts. Knowing the characteristics of different superior right hepatic vein types and of the accessory right hepatic veins may be useful in segment-oriented liver resections and in right side living donor resections.
Canine Breed-Specific Hepatopathies.
Watson, Penny
2017-05-01
Canine hepatopathies, both congenital and acquired, arise from an interaction between genes and environment. Many show increased breed prevalences. This article reviews the current understanding on breed predispositions for congenital portosystemic shunts; microvascular dysplasia and portal vein hypoplasia; ductal plate abnormalities (congenital hepatic fibrosis and Caroli disease); chronic hepatitis (both copper associated and idiopathic); vacuolar hepatopathies; and gallbladder mucocele. Although all these diseases can occur in many breeds and crossbreeds, understanding breed predispositions helps recognition and will guide future research to improve understanding of causes and treatments. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Treatment of hepatocellular carcinoma with portal vein tumor thrombus: advances and challenges.
Jiang, Jin-Fang; Lao, Yong-Cong; Yuan, Bao-Hong; Yin, Jun; Liu, Xin; Chen, Long; Zhong, Jian-Hong
2017-05-16
Portal vein tumor thrombus is a frequent, challenging complication in hepatocellular carcinoma. Hepatocellular carcinoma patients with portal vein tumor thrombus may show worse liver function, less treatment tolerance and worse prognosis than patients without portal vein tumor thrombus, and they may be at higher risk of comorbidity related to portal hypertension. Western and some Asian guidelines stratify hepatocellular carcinoma with portal vein tumor thrombus together with metastatic hepatocellular carcinoma and therefore recommend only palliative treatment with sorafenib or other systemic agents. In recent years, more treatment options have become available for hepatocellular carcinoma patients with portal vein tumor thrombus, and an evidence-based approach to optimizing disease management and treatment has become more widespread. Nevertheless, consensus policies for managing hepatocellular carcinoma with portal vein tumor thrombus have not been established. This comprehensive literature review, drawing primarily on studies published after 2010, examines currently available management options for patients with hepatocellular carcinoma and portal vein tumor thrombus.
Baltsavias, Gerasimos; Parthasarathi, Venkatraman; Aydin, Emre; Al Schameri, Rahman A; Roth, Peter; Valavanis, Anton
2015-04-01
We reviewed the anatomy and embryology of the bridging and emissary veins aiming to elucidate aspects related to the cranial dural arteriovenous fistulae. Data from relevant articles on the anatomy and embryology of the bridging and emissary veins were identified using one electronic database, supplemented by data from selected reference texts. Persisting fetal pial-arachnoidal veins correspond to the adult bridging veins. Relevant embryologic descriptions are based on the classic scheme of five divisions of the brain (telencephalon, diencephalon, mesencephalon, metencephalon, myelencephalon). Variation in their exact position and the number of bridging veins is the rule and certain locations, particularly that of the anterior cranial fossa and lower posterior cranial fossa are often neglected in prior descriptions. The distal segment of a bridging vein is part of the dural system and can be primarily involved in cranial dural arteriovenous lesions by constituting the actual site of the shunt. The veins in the lamina cribriformis exhibit a bridging-emissary vein pattern similar to the spinal configuration. The emissary veins connect the dural venous system with the extracranial venous system and are often involved in dural arteriovenous lesions. Cranial dural shunts may develop in three distinct areas of the cranial venous system: the dural sinuses and their interfaces with bridging veins and emissary veins. The exact site of the lesion may dictate the arterial feeders and original venous drainage pattern.
NASA Astrophysics Data System (ADS)
Micheuz, Peter; Quandt, Dennis; Kurz, Walter
2017-04-01
International Ocean Discovery Program (IODP) expeditions 352 and 351 drilled through oceanic crust of the Philippine Sea plate. The two study areas are located near the outer Izu-Bonin-Mariana (IBM) fore arc and in the Amami Sankaku Basin. The primary objective was to improve our understanding of supra-subduction zones (SSZ) and the process of subduction initiation. The recovered drill cores during IODP expedition 352 represent approximately 50 Ma old fore arc basalts (FAB) and boninites revealing an entire volcanic sequence of a SSZ. Expedition 351 drilled FAB like oceanic crust similar in age to the FABs of expedition 352. In this study we present data on vein microstructures, geochemical data and isotopic signatures of vein precipitates to give new insights into fluid flow and precipitation processes and deformation within the Izu-Bonin fore arc. Veins formed predominantly as a consequence of hydrofracturing resulting in the occurrence of branched vein systems and brecciated samples. Along these hydrofractures the amount of altered host rock fragments varies and locally alters the host rock completely to zeolites and carbonates. Subordinately extensional veins released after the formation of the host rocks. Cross-cutting relationships of different vein types point to multiple fracturing events subsequently filled with minerals originating from a fluid with isotopic seawater signature. Based on vein precipitates, their morphology and their growth patterns four vein types have been defined. Major vein components are (Mg-) calcite and various zeolites determined by Raman spectra and electron microprobe analyses. Zeolites result from alteration of volcanic glass during interaction with a seawaterlike fluid. Type I veins which are characterized by micritic infill represent neptunian dykes. They predominantly occur in the upper levels of drill cores being the result of an initial volume change subsequently to crystallization of the host rocks. Type II veins are characterized by blocky carbonates and idiomorphic to blocky zeolites. Blocky carbonates locally exhibit zonation patterns. Type III and type IV veins are both assumed to be extensional veins. Type III is characterized by syntaxial growth and elongate blocky carbonate minerals. They predominantly occur as asymmetric syntaxial veins, locally exhibiting more than one crack-seal event. Type IV veins are defined as antitaxial fibrous carbonates. Type II veins commonly show deformation microstructures like twinning (type I/II twins), slightly curved twins, and subgrain boundaries indicative of incipient plastic deformation. Based on these observations differential stresses around 50 MPa were needed to deform vein minerals, presumably related to IBM fore arc extension due to the retreat of the subducted Pacific plate. We acknowledge financial support by the Austrian Research Fund (P27982-N29) to W. Kurz
Segmentation of Dilated Hemorrhoidal Veins in Hemorrhoidal Disease.
Díaz-Flores, Lucio; Gutiérrez, Ricardo; González-Gómez, Miriam; García, Pino; Sáez, Francisco J; Díaz-Flores, Lucio; Carrasco, José Luis; Madrid, Juan F
2018-06-18
Vein segmentation is a vascular remodeling process mainly studied in experimental conditions and linked to hemodynamic factors, with clinical implications. The aim of this work is to assess the morphologic characteristics, associated findings, and mechanisms that participate in vein segmentation in humans. To this end, we examined 156 surgically obtained cases of hemorrhoidal disease. Segmentation occurred in 65 and was most prominent in 15, which were selected for serial sections, immunohistochemistry, and immunofluorescence procedures. The dilated veins showed differently sized spaces, separated by thin septa. Findings associated with vein segmentation were: (a) vascular channels formed from the vein intima endothelial cells (ECs) and located in the vein wall and/or intraluminal fibrin, (b) vascular loops formed by interconnected vascular channels (venous-venous connections), which encircled vein wall components or fibrin and formed folds/pillars/papillae (FPPs; the encircling ECs formed the FPP cover and the encircled components formed the core), and (c) FPP splitting, remodeling, alignment, and fusion, originating septa. Thrombosis was observed in some nonsegmented veins, while the segmented veins only occasionally contained thrombi. Dense microvasculature was also present in the interstitium and around veins. In conclusion, the findings suggest that hemorrhoidal vein segmentation is an adaptive process in which a piecemeal angiogenic mechanism participates, predominantly by intussusception, giving rise to intravascular FPPs, followed by linear rearrangement, remodeling and fusion of FPPs, and septa formation. Identification of other markers, as well as the molecular bases, hemodynamic relevance, and possible therapeutic implications of vein segmentation in dilated hemorrhoidal veins require further studies. © 2018 S. Karger AG, Basel.
An Automated Mouse Tail Vascular Access System by Vision and Pressure Feedback.
Chang, Yen-Chi; Berry-Pusey, Brittany; Yasin, Rashid; Vu, Nam; Maraglia, Brandon; Chatziioannou, Arion X; Tsao, Tsu-Chin
2015-08-01
This paper develops an automated vascular access system (A-VAS) with novel vision-based vein and needle detection methods and real-time pressure feedback for murine drug delivery. Mouse tail vein injection is a routine but critical step for preclinical imaging applications. Due to the small vein diameter and external disturbances such as tail hair, pigmentation, and scales, identifying vein location is difficult and manual injections usually result in poor repeatability. To improve the injection accuracy, consistency, safety, and processing time, A-VAS was developed to overcome difficulties in vein detection noise rejection, robustness in needle tracking, and visual servoing integration with the mechatronics system.
Vein mineralizations - archives of paleo-fluid systems in the Thuringian basin (Germany)
NASA Astrophysics Data System (ADS)
Abratis, M.; Brey, M.; Fritsch, S.; Majzlan, J.; Viereck-Götte, L.
2012-04-01
We investigate vein mineralizations within and around the Thuringian basin (Germany) in order to characterize paleo-fluid systems that have been active in the basin. By investigating the composition, temperature, origin, age and evolution of paleo-fluids in the Thuringian basin as a model case, we aim for comprehensive understanding of the character of mineralized fluid systems in sedimentary basins in general and their evolution over geological time scales. Mineralizations along faults are archives for the composition of fluids which intruded the basin and circulated within it millions of years ago. These mineralizations give information on the physical and chemical characteristics of the related fluids as well as on their evolution with time during basin evolution. Mapping of mineralizations in space and time and comparison with the present-day fluid circulation system allows for recognition of the paleo-fluid dynamics and high temperature fluid influx pathways. The chemical characteristics of vein-related mineralizations are proxies for the paleo-fluid sources and their solution load. Methods implied comprise bulk rock analyses (petrography, XRD, XRF, ICP-MS), mineral analyses (EPMA, LA-ICP-MS), fluid inclusion measurements (microthermometry, Raman spectroscopy, ion chromatography) and isotope studies (O, H, C, S, Sr). Vein-related mineralizations within the Mesozoic sediments of the basin occur predominantly along WNW-ESE trending fault systems and comprise mainly carbonates and sulfates. Mineralizations within the basin-confining uplifted Variscan basement rocks and lowermost sedimentary units (Zechstein) show also (Fe-, Cu-, Zn-, As-, Sb-) sulfides, (Fe-, Mn-) oxides, fluorite and barite. The present study is part of INFLUINS, a BMBF-funded project bundle which is dedicated to comprehensive description and understanding of the fluid systems within the Thuringian basin in time and space.
NASA Astrophysics Data System (ADS)
Nachon, M.; Sumner, D. Y.; Borges, S. R.; Stack, K.; Stein, N.; Watkins, J. A.; Banham, S.; Rivera-Hernandez, F.; Wiens, R. C.; l'Haridon, J.; Rapin, W.; Kronyak, R. E.
2017-12-01
Since landing at Gale crater, Mars, in August 2012, the Curiosity rover has driven through more than 300m of stratigraphy. From the first to the most recent sedimentary rocks explored, light-toned veins have been observed cutting the host-rock and were interpreted as diagenetic features emplaced by hydraulic fracturing. Chemical and mineralogical analyses show they consist of Ca-sulfate. Here we report on the veins' distribution within two geological formations explored more recently by the rover: (a) the Murray Formation that consists mainly of fine-grained laminated rocks that have been interpreted as having been deposited in a former lacustrine environment [1], and (b) the Stimson Formation, which lies unconformably above the Murray, and consists of cross bedded sandstones interpreted as being deposited in a aeolian environment [2]. We have performed a systematic observation of the veins within the MastCam images, from the base of the Murray (Sol 750) up to Sol 1515 [3], described their main geometrical characteristics (e.g. orientation to laminae, relative density, branching). Five veins facies were defined based on veins' geometrical properties, abundance, and host-rock grain size. The distribution of veins facies was placed within the broader stratigraphic context. The distribution of veins within the Murray and Stimson Formations shows strong rheological controls. In the Murray, light-toned veins are present from the basal part of the section up to the most recently explored exposures. Several dense vein outcrops are associated with local variations in host-rock type, suggesting rheological control of fluid circulation. In Stimson sandstones, light-toned veins are also present though much rarer, again possibly due to rheological properties. The light-toned veins represent post depositional fluid circulation, occurring after accumulation of the lacustrine Murray rocks; at least some veins formed after Murray's burial, erosion, and the deposition and lithification of the overlying Stimson aeolian rocks. Given the distribution of veins, ground water was likely present during an extended time interval, spanning a duration of at least millions of years. [1]Grotzinger et al., 2015, DOI: 10.1126/science.aac7575 [2]Banham et al., 2017, this meeting [3]Nachon et al., 2017, AbSciCon #3667
TrapEase inferior vena cava filter placement: use of the subclavian vein.
Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A
2004-01-01
The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access and where combined long-term central venous catheter placement using the subclavian vein is desirable.
USDA-ARS?s Scientific Manuscript database
Yellow vein clearing virus, an uncharacterized filamentous virus, was first observed in Pakistan in 1988 and later in India in 1997 in Etrog citron (Citrus medica). Based on electron microscopic evidence of filamentous particles, the virus, provisionally named Citrus yellow vein clearing virus (CYVC...
Lee, Jaekwon; Moon, Seunghwan; Lim, Juhun; Gwak, Min-Joo; Kim, Jae Gwan; Chung, Euiheon; Lee, Jong-Hyun
2017-04-22
A new authentication method employing a laser and a scanner is proposed to improve image contrast of the finger vein and to extract blood flow pattern for liveness detection. A micromirror reflects a laser beam and performs a uniform raster scan. Transmissive vein images were obtained, and compared with those of an LED. Blood flow patterns were also obtained based on speckle images in perfusion and occlusion. Curvature ratios of the finger vein and blood flow intensities were found to be nearly constant, regardless of the vein size, which validated the high repeatability of this scheme for identity authentication with anti-spoofing.
Lee, Jaekwon; Moon, Seunghwan; Lim, Juhun; Gwak, Min-Joo; Kim, Jae Gwan; Chung, Euiheon; Lee, Jong-Hyun
2017-01-01
A new authentication method employing a laser and a scanner is proposed to improve image contrast of the finger vein and to extract blood flow pattern for liveness detection. A micromirror reflects a laser beam and performs a uniform raster scan. Transmissive vein images were obtained, and compared with those of an LED. Blood flow patterns were also obtained based on speckle images in perfusion and occlusion. Curvature ratios of the finger vein and blood flow intensities were found to be nearly constant, regardless of the vein size, which validated the high repeatability of this scheme for identity authentication with anti-spoofing. PMID:28441728
NASA Astrophysics Data System (ADS)
Manning, C. E.; Nozaka, T.; Harris, M.; Michibayashi, K.; de Obeso, J. C.; D'Andres, J.; Lefay, R.; Leong, J. A. M.; Zeko, D.; Kelemen, P. B.; Teagle, D. A. H.
2017-12-01
Oman Drilling Project Hole GT3A intersected 400 m of altered basaltic dikes, gabbros, and diorites. The 100% recovery affords an unprecedented opportunity to study metamorphism and hydrothermal alteration near the dike-gabbro transition in the ocean crust. Hydrothermal alteration is ubiquitous; all rocks are at least moderately altered, and mean alteration intensity is 54%. The earliest alteration in all rock types is background replacement of igneous minerals, some of which occurred at clinopyroxene amphibolite facies, as indicated by brown-green hornblende, calcic plagioclase, and secondary cpx. In addition, background alteration includes greenschist, subgreenschist, and zeolite facies minerals. More extensive alteration is locally observed in halos around veins, patches, and zones related to deformation. Dense networks of hydrothermal veins record a complex history of fluid-rock alteration. During core description, 10,727 individual veins and 371 vein networks were logged in the 400 m of Hole GT3A. The veins displayed a range of textures and connectivities. The total density of veins in Hole GT3A is 26.8 veins m-1. Vein density shows no correlation with depth, but may be higher near dike margins and faults. Vein minerals include amphibole, epidote, quartz, chlorite, prehnite, zeolite (chiefly laumontite) and calcite in a range of combinations. Analysis of crosscutting relations leads to classification of 4 main vein types. In order of generally oldest to youngest these are: amphibole, quartz-epidote-chlorite (QEC), zeolite-prehnite (ZP), and calcite. QEC and ZP vein types may contain any combination of minerals except quartz alone; veins filled only by quartz may occur at any relative time. Macroscopic amphibole veins are rare and show no variation with depth. QEC vein densities appear to be higher (>9.3 veins m-1) in the upper 300 m of GT3A, where dikes predominate. In contrast, there are 5.5 veins m-1 at 300-400 m, where gabbros and diorites are abundant. ZP veins increase in density downhole; the highest density of 17.5 ZP veins/m occurs in the lowest 100 m where substantial faulting is observed. Equilibrium coexistence of laumontite and prehnite in ZP veins implies formation at 100-250 °C, lower than amphibole and QEC veins. Calcite veins are abundant only in the uppermost 100 m of the hole.
NASA Astrophysics Data System (ADS)
Pirajno, Franco; González-Álvarez, Ignacio; Chen, Wei; Kyser, Kurt T.; Simonetti, Antonio; Leduc, Evelyne; leGras, Monica
2014-08-01
The Gifford Creek Ferrocarbonatite Complex (GFC), located in the Neoarchean-Palaeoproterozoic Gascoyne Province, Western Australia, comprises sills, dykes, and veins of ferrocarbonatite intruding the Pimbyana Granite and Yangibana Granite of the Durlacher Supersuite and metasedimentary rocks of the Pooranoo Metamorphics. The ferrocarbonatites are associated with complex and irregularly distributed zones of fenitic alteration. These ferrocarbonatites and fenites are also associated with a swarm of ironstone veins, containing magnetite, hematite and goethite. The GFC and associated fenite outcrops are distributed within a ~ 700 km2 area, north of the Lyons River Fault. Ferrocarbonatite sills and dykes are predominant in a northwest-trending belt, along the southern margin of the complex; whereas ferrocarbonatite veins tend to be distributed in a series of sub-parallel west-northwest-trending linear belts, generally associated with the Fe oxide veins with sinuous trends. These veins have margins of Fe-rich carbonates associated with zones of alteration that have a fenitic character. The fenitic haloes are characterised by the presence of Na-K-feldspars and/or Na-amphiboles and magnetite. In some cases monomineralic feldspar zones (orthoclasite) are present. Fenitic alteration is spatially associated with the carbonatites, but it can also form discrete veins and veinlets in basement granitic rocks (Pimbyana and Yangibana Granites). Petrographic, XRD and SEM analyses show that the ferrocarbonatites are dominantly composed of ankerite-dolomite, magnetite, arfvedsonite-riebeckite, and lesser calcite. Alkali amphibole has compositions ranging from potassian magnesio-arfvedsonite to magnesio-riebeckite. Sills and dykes north of the Lyons River, are characterised by a carbonate-rich matrix, containing > 50 vol.% ankerite-dolomite, with accessory quantities of apatite, barite, monazite, and phlogopite. In-situ U-Pb age determination of apatite grains by LA-ICP-MS on a sample of ferrocarbonatite was performed and an average age of 1075 ± 35 Ma was obtained. This age is within the range of ages (~ 1078-1070 Ma) of the Warakurna Large Igneous Province (WLIP) and we suggest that the GFC is related to the mantle plume event that generated the WLIP. This is a significant outcome, because it may lead to the recognition or discovery of other carbonatites within the area covered by the WLIP. In addition, monazite from fenitic rocks associated with the ironstones yielded an age of 1050 ± 25 Ma, suggesting that a second phase of carbonatite magmatism occurred, resulting in the emplacement of the carbonatite-ironstone veins swarm. A model is proposed to explain the formation of the GFC system.
Polguj, Michał; Sopiński, Marek; Jędrzejewski, Kazimierz; Bolanowski, Wojciech; Topol, Mirosław
2011-10-01
Histological and corrosive studies of 75 bovine testes were focused on the vascular complex of the tunica albuginea. Thanks to used MultiScanBase v.14.02 software arterial and venous vessels and also vascular anastomoses were analyzed preciously. The studies revealed the superficial layer containing vessels of smaller diameter and reduced wall structure and the deeper layer with wider, winding vessels and complete wall structure. The branches of the testicular artery and intra-tunical veins formed a vascular complex of the tunica albuginea. The intra-tunical veins were divided into two types. Type I veins ran parallel, drained intra-parenchymal veins and formed the origin of pampiniform plexus. Type II veins drained into type I intra-tunical veins. Indirect anastomoses among intra-tunical veins and arteries and venovenous connections were observed. The results of the study could contribute fuller description of the regulatory mechanism for testicular blood supply and optimization of the testicular biopsy to minimize bleeding risk. Copyright © 2010 Elsevier Ltd. All rights reserved.
Zyuzin, Mikhail V; Yan, Yan; Hartmann, Raimo; Gause, Katelyn T; Nazarenus, Moritz; Cui, Jiwei; Caruso, Frank; Parak, Wolfgang J
2017-08-16
The presence of a protein corona on various synthetic nanomaterials has been shown to strongly influence how they interact with cells. However, it is unclear if the protein corona also exists on protein particles, and if so, its role in particle-cell interactions. In this study, pure human serum albumin (HSA) particles were fabricated via mesoporous silica particle templating. Our data reveal that various serum proteins adsorbed on the particles, when exposed to human blood plasma, forming a corona. In human umbilical vein endothelial cells (HUVECs), the corona was shown to decrease particle binding to the cell membrane, increase the residence time of particles in early endosomes, and reduce the amount of internalized particles within the first hours of exposure to particles. These findings reveal important information regarding the mechanisms used by vascular endothelial cells to internalize protein-based particulate materials exposed to blood plasma. The ability to control the cellular recognition of these organic particles is expected to aid the advancement of HSA-based materials for intravenous drug delivery.
The research and application of multi-biometric acquisition embedded system
NASA Astrophysics Data System (ADS)
Deng, Shichao; Liu, Tiegen; Guo, Jingjing; Li, Xiuyan
2009-11-01
The identification technology based on multi-biometric can greatly improve the applicability, reliability and antifalsification. This paper presents a multi-biometric system bases on embedded system, which includes: three capture daughter boards are applied to obtain different biometric: one each for fingerprint, iris and vein of the back of hand; FPGA (Field Programmable Gate Array) is designed as coprocessor, which uses to configure three daughter boards on request and provides data path between DSP (digital signal processor) and daughter boards; DSP is the master processor and its functions include: control the biometric information acquisition, extracts feature as required and responsible for compare the results with the local database or data server through network communication. The advantages of this system were it can acquire three different biometric in real time, extracts complexity feature flexibly in different biometrics' raw data according to different purposes and arithmetic and network interface on the core-board will be the solution of big data scale. Because this embedded system has high stability, reliability, flexibility and fit for different data scale, it can satisfy the demand of multi-biometric recognition.
Omura, Kensuke; Ota, Hideki; Takahashi, Yuuki; Matsuura, Tomonori; Seiji, Kazumasa; Arai, Yoichi; Morimoto, Ryo; Satoh, Fumitoshi; Takase, Kei
2017-03-01
Adrenal venous sampling is the most reliable diagnostic procedure to determine surgical indications in primary aldosteronism. Because guidelines recommend multidetector computed tomography (CT) to evaluate the adrenal gland, some past reports used multidetector CT as a guide for adrenal venous sampling. However, the detailed anatomy of the right adrenal vein and its relationship with an accessory hepatic vein remains uncertain. The purpose of this study was to describe detailed anatomical variations of the right adrenal vein and to determine the concordance between CT and catheter venography in patients with primary aldosteronism. In total, 440 consecutive patients who underwent adrenal venous sampling were included. Four-phase dynamic CT was performed. Anatomical locations and variations of the right adrenal vein and its relationship with the accessory hepatic vein were compared with catheter venographic findings. Successful catheterization was achieved in 437 patients (99%). The right adrenal vein was visualized in the late arterial phase with CT in 420 patients (95%). The right adrenal vein formed a common trunk with the accessory hepatic vein in 87 patients (20%). CT identified the correct craniocaudal level of the orifice in 354 patients (84%). Anatomical variations, location, and angle of inflow of the right adrenal vein based on CT demonstrated high concordance with catheter venography. CT may provide useful information for preparation before adrenal venous sampling. © 2017 American Heart Association, Inc.
Hikspoors, Jill P J M; Peeters, Mathijs M J P; Kruepunga, Nutmethee; Mekonen, Hayelom K; Mommen, Greet M C; Köhler, S Eleonore; Lamers, Wouter H
2017-12-07
Couinaud based his well-known subdivision of the liver into (surgical) segments on the branching order of portal veins and the location of hepatic veins. However, both segment boundaries and number remain controversial due to an incomplete understanding of the role of liver lobes and vascular physiology on hepatic venous development. Human embryonic livers (5-10 weeks of development) were visualized with Amira 3D-reconstruction and Cinema 4D-remodeling software. Starting at 5 weeks, the portal and umbilical veins sprouted portal-vein branches that, at 6.5 weeks, had been pruned to 3 main branches in the right hemi-liver, whereas all (>10) persisted in the left hemi-liver. The asymmetric branching pattern of the umbilical vein resembled that of a "distributing" vessel, whereas the more symmetric branching of the portal trunk resembled a "delivering" vessel. At 6 weeks, 3-4 main hepatic-vein outlets drained into the inferior caval vein, of which that draining the caudate lobe formed the intrahepatic portion of the caval vein. More peripherally, 5-6 major tributaries drained both dorsolateral regions and the left and right ventromedial regions, implying a "crypto-lobar" distribution. Lobar boundaries, even in non-lobated human livers, and functional vascular requirements account for the predictable topography and branching pattern of the liver veins, respectively.
NASA Astrophysics Data System (ADS)
Klöcking, M.; White, N. J.; Maclennan, J.; Fitton, J. G.
2016-12-01
The Troodos ophiolite, Cyprus, is one of the best preserved ophiolites. Based on geochemical data a supra-subduction zone (SSZ) setting was proposed. Microtextures and fluid inclusions of veins and vesicles within the Pillow Lavas record the post-magmatic structural and geochemical evolution of this SSZ beginning at 75 Ma. Three different vein types from the Upper and Lower Pillow Lavas are distinguished and imply vein precipitation under a dominant extensional regime: (1) syntaxial calcite-, quartz- and zeolite-bearing veins are interpreted as mineralized extension fractures that were pervaded by seawater. This advective fluid flow in an open system changed later into a closed system characterized by geochemical self-organization. (2) Blocky and (3) antitaxial fibrous calcite veins are associated with brecciation due to hydrofracturing and diffusion-crystallization processes, respectively. Based on aqueous fluid inclusion chemistry with seawater salinities in all studied vein types, representative fluid inclusion isochores crossed with calculated litho- and hydrostatic pressure conditions yield mineral precipitation temperatures between 180 and 210 °C, for veins and vesicles hosted in the Upper and Lower Pillow Lavas. This points to a heat source for the circulating seawater and implies that vein and vesicle minerals precipitated shortly after pillow lava crystallization under dominant isobaric cooling conditions. Compared to previous suggestions derived from secondary mineralization a less steep geothermal gradient of 200 °C from the Sheeted Dyke Complex to the Pillow Lavas of the Troodos SSZ is proposed. Further fossil and recent SSZ like the Mirdita ophiolite, Albania, the South-Anatolian ophiolites, Turkey, and the Izu-Bonin fore arc, respectively, reveal similar volcanic sequences. Vein samples recovered during International Ocean Discovery Program expedition 351 and 352 in the Izu-Bonin back and fore arc, respectively, indicate also seawater infiltration into fractures but low-temperature (<150 °C) mineral precipitation. This comparison of spatially and temporally unrelated vein systems contributes to the understanding of post-magmatic structural and geochemical processes in SSZ. This study was granted by the Austrian Science Fund (FWF-P 27982-N29).
NASA Astrophysics Data System (ADS)
Kurz, W.; Quandt, D.; Micheuz, P.; Krenn, K.
2017-12-01
The Troodos ophiolite, Cyprus, is one of the best preserved ophiolites. Based on geochemical data a supra-subduction zone (SSZ) setting was proposed. Microtextures and fluid inclusions of veins and vesicles within the Pillow Lavas record the post-magmatic structural and geochemical evolution of this SSZ beginning at 75 Ma. Three different vein types from the Upper and Lower Pillow Lavas are distinguished and imply vein precipitation under a dominant extensional regime: (1) syntaxial calcite-, quartz- and zeolite-bearing veins are interpreted as mineralized extension fractures that were pervaded by seawater. This advective fluid flow in an open system changed later into a closed system characterized by geochemical self-organization. (2) Blocky and (3) antitaxial fibrous calcite veins are associated with brecciation due to hydrofracturing and diffusion-crystallization processes, respectively. Based on aqueous fluid inclusion chemistry with seawater salinities in all studied vein types, representative fluid inclusion isochores crossed with calculated litho- and hydrostatic pressure conditions yield mineral precipitation temperatures between 180 and 210 °C, for veins and vesicles hosted in the Upper and Lower Pillow Lavas. This points to a heat source for the circulating seawater and implies that vein and vesicle minerals precipitated shortly after pillow lava crystallization under dominant isobaric cooling conditions. Compared to previous suggestions derived from secondary mineralization a less steep geothermal gradient of 200 °C from the Sheeted Dyke Complex to the Pillow Lavas of the Troodos SSZ is proposed. Further fossil and recent SSZ like the Mirdita ophiolite, Albania, the South-Anatolian ophiolites, Turkey, and the Izu-Bonin fore arc, respectively, reveal similar volcanic sequences. Vein samples recovered during International Ocean Discovery Program expedition 351 and 352 in the Izu-Bonin back and fore arc, respectively, indicate also seawater infiltration into fractures but low-temperature (<150 °C) mineral precipitation. This comparison of spatially and temporally unrelated vein systems contributes to the understanding of post-magmatic structural and geochemical processes in SSZ. This study was granted by the Austrian Science Fund (FWF-P 27982-N29).
Stolz, Erwin; Yeniguen, Mesut; Kreisel, Melanie; Kampschulte, Marian; Doenges, Simone; Sedding, Daniel; Ritman, Erik L; Gerriets, Tibo; Langheinrich, Alexander C
2011-02-01
It is well known that recanalization of thrombosed cerebral sinuses occurs early but without marked influence on the long-term outcome and on final venous infarct volume on magnetic resonance imaging. To better understand the possible microvascular mechanisms behind these clinical observations, we evaluated the sequels of subacute superior sagittal sinus (SSS) thrombosis in rats using micro- and nano-CT imaging of the same specimen to provide large volume and high resolution CT image data respectively. SSS thrombosis was induced in 11 animals which were euthanized after 6h (n=4) or 6 weeks (n=7). Eight sham-operated rats served as controls. After infusion of contrast into the vasculature of the brains, these were isolated and scanned using micro-, nano-, and synchrotron-based micro-CT ((8 μm³), (900 nm)³, and (1.9 μm³) voxel sizes). The cross-sectional area of the superior sagittal sinus, microvessels and cortical veins were quantified. Tissue sections were stained against VEGF antigen. Immunohistochemistry was confirmed using quantitative rtPCR. SSS thrombosis led to a congestion of the bridging veins after 6h. After 6 weeks, a network of small vessels surrounding the occluded SSS was present with concurrent return towards the diameter of the draining bridging veins of controls. This microvascular network connected to cortical veins as demonstrated by nano- and synchrotron-based micro-CT. Also the volume fraction and number of cortical veins increased significantly. Immunohistochemistry in the region of the microsvascular network demonstrated a strong immunoreactivity against VEGF, confirmed by rtPCR. The sequel of subacute SSS thrombosis induced a network of microvessels ("venogenesis") draining the bridging veins. Also the volume fraction of cortical veins increased significantly. Copyright © 2010 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
E Stolz; M Yeniguen; M Kreisel
2011-12-31
It is well known that recanalization of thrombosed cerebral sinuses occurs early but without marked influence on the long-term outcome and on final venous infarct volume on magnetic resonance imaging. To better understand the possible microvascular mechanisms behind these clinical observations, we evaluated the sequels of subacute superior sagittal sinus (SSS) thrombosis in rats using micro- and nano-CT imaging of the same specimen to provide large volume and high resolution CT image data respectively. SSS thrombosis was induced in 11 animals which were euthanized after 6 h (n = 4) or 6 weeks (n = 7). Eight sham-operated rats servedmore » as controls. After infusion of contrast into the vasculature of the brains, these were isolated and scanned using micro-, nano-, and synchrotron-based micro-CT ((8 {mu}m{sup 3}), (900 nm){sup 3}, and (1.9 {mu}m{sup 3}) voxel sizes). The cross-sectional area of the superior sagittal sinus, microvessels and cortical veins were quantified. Tissue sections were stained against VEGF antigen. Immunohistochemistry was confirmed using quantitative rtPCR. SSS thrombosis led to a congestion of the bridging veins after 6 h. After 6 weeks, a network of small vessels surrounding the occluded SSS was present with concurrent return towards the diameter of the draining bridging veins of controls. This microvascular network connected to cortical veins as demonstrated by nano- and synchrotron-based micro-CT. Also the volume fraction and number of cortical veins increased significantly. Immunohistochemistry in the region of the microsvascular network demonstrated a strong immunoreactivity against VEGF, confirmed by rtPCR. The sequel of subacute SSS thrombosis induced a network of microvessels ('venogenesis') draining the bridging veins. Also the volume fraction of cortical veins increased significantly.« less
NASA Astrophysics Data System (ADS)
Radmard, Kaikhosrov; Zamanian, Hassan; Hosseinzadeh, Mohamad Reza; Khalaji, Ahmad Ahmadi
2017-12-01
Situated about 130 km northeast of Tabriz (northwest Iran), the Mazra'eh Shadi deposit is in the Arasbaran metallogenic belt (AAB). Intrusion of subvolcanic rocks, such as quartz monzodiorite-diorite porphyry, into Eocene volcanic and volcano-sedimentary units led to mineralisation and alteration. Mineralisation can be subdivided into a porphyry system and Au-bearing quartz veins within andesite and trachyandesite which is controlled by fault distribution. Rock samples from quartz veins show maximum values of Au (17100 ppb), Pb (21100 ppm), Ag (9.43ppm), Cu (611ppm) and Zn (333 ppm). Au is strongly correlated with Ag, Zn and Pb. In the Au-bearing quartz veins, factor group 1 indicates a strong correlation between Au, Pb, Ag, Zn and W. Factor group 2 indicates a correlation between Cu, Te, Sb and Zn, while factor group 3 comprises Mo and As. Based on Spearman correlation coefficients, Sb and Te can be very good indicator minerals for Au, Ag and Pb epithermal mineralisation in the study area. The zoning pattern shows clearly that base metals, such as Cu, Pb, Zn and Mo, occur at the deepest levels, whereas Au and Ag are found at higher elevations than base metals in boreholes in northern Mazra'eh Shadi. This observation contrasts with the typical zoning pattern caused by boiling in epithermal veins. At Mazra'eh Shadi, quartz veins containing co-existing liquid-rich and vapour-rich inclusions, as strong evidence of boiling during hydrothermal evolution, have relatively high Au grades (up to 813 ppb). In the quartz veins, Au is strongly correlated with Ag, and these elements are in the same group with Fe and S. Mineralisation of Au and Ag is a result of pyrite precipitation, boiling of hydrothermal fluids and a pH decrease.
NASA Astrophysics Data System (ADS)
Rustichelli, Andrea; Di Celma, Claudio; Tondi, Emanuele; Baud, Patrick; Vinciguerra, Sergio
2016-04-01
New knowledge on patterns of fibrous gypsum veins, their genetic mechanisms, deformation style and weathering are provided by a field- and laboratory-based study carried out on the Neogene to Quaternary Pisco Basin sedimentary strata (porous sandstones, siltstones and diatomites) exposed in the Ica desert, southern Peru. Gypsum veins vary considerably in dimensions, attitudes and timing and can develop in layered and moderately fractured rocks also in the absence of evaporitic layers. Veins occur both as diffuse features, confined to certain stratigraphic levels, and localised within fault zones. Arrays formed by layer-bounded, mutually orthogonal sets of steeply-dipping gypsum veins are reported for the first time. Vein length, height and spacing depend on the thickness of the bed packages in which they are confined. Within fault zones, veins are partly a product of faulting but also inherited layer-bounded features along which faults are superimposed. Due to the different petrophysical properties with respect to the parent rocks and their susceptibility to textural and mineralogical modifications, water dissolution and rupture, gypsum veins may have a significant role in geofluid management. Depending on their patterns and grade of physical and chemical alteration, veins may influence geofluid circulation and storage, acting as barriers to flow and possibly also as conduits.
NASA Technical Reports Server (NTRS)
Parsons-Wingerter, Patricia A.; Hosamani, Ravikumar; Bhattacharya, Sharmila
2015-01-01
Imaginal wing discs of Drosophila melanogaster (fruit fly) defined during embryogenesis ultimately result in mature wings of stereotyped (specific) venation patterning. Major regulators of wing disc development are the epidermal growth factor receptor (EGF), Notch, Hedgehog (Hh), Wingless (Wg), and Dpp signaling pathways. Highly stereotyped vascular patterning is also characteristic of tissues in other organisms flown in space such as the mouse retina and leaves of Arabidopsis thaliana. Genetic and other adaptations of vascular patterning to space environmental factors have not yet been systematically quantified, despite widespread recognition of their critical importance for terrestrial and microgravity applications. Here we report changes in gene expression with space flight related to Drosophila wing morphogenesis and vein patterning. In addition, genetically modified phenotypes of increasingly abnormal ectopic wing venation in the Drosophila wing1 were analyzed by NASA's VESsel GENeration Analysis (VESGEN) software2. Our goal is to further develop insightful vascular mappings associated with bioinformatic dimensions of genetic or other molecular phenotypes for correlation with genetic and other molecular profiling relevant to NASA's GeneLab and other Space Biology exploration initiatives.
Techniques of adrenal venous sampling in patients with inferior vena cava or renal vein anomalies.
Endo, Kenji; Morita, Satoru; Suzaki, Shingo; Yamazaki, Hiroshi; Nishina, Yu; Sakai, Shuji
2018-06-01
To review the techniques and technical success rate of adrenal venous sampling (AVS) in patients with inferior vena cava (IVC) or renal vein anomalies. The techniques and success rate of AVS in 15 patients with anomalies [8 with double IVC (dIVC), 3 with left IVC (ltIVC), 2 with retroaortic left renal vein (LRV), and 2 with circumaortic LRV] underwent AVS was retrospectively reviewed. Among 11 patients with IVC anomalies, the success rates for sampling the right and left adrenal veins (RAV and LAV) were 81.8 and 90.9%, respectively. In dIVC, the LAV was selected using the following four methods: approaching through the right IVC from the right femoral vein, flipping the LAV catheter tip in the LRV (n = 4) or the interiliac-communicating vein (n = 1), or through the ltIVC from the right (n = 1) or left (n = 2) femoral vein. Among the four patients with LRV anomalies, the success rate was 100% for each adrenal vein. AVS can be successfully performed in patients with anomalies. The key to technical success is understanding the venous anatomy based on pre-procedural CT images and choosing appropriate methods.
Choy, Jenny Susana; Dang, Quang; Molloi, Sabee; Kassab, Ghassan S
2006-04-01
The pressure-induced remodeling of coronary veins is important in coronary venous retroperfusion. Our hypothesis is that the response of the large coronary veins to pressure overload will depend on the degree of myocardial support. Eleven normal Yorkshire swine from either sex, weighing 31-39 kg, were studied. Five pigs underwent ligation of the left anterior descending (LAD) vein, and six served as sham-operated controls. The ligation of the coronary vein caused an increase in pressure intermediate to arterial and venous values. After 2 wk of ligation, the animals were euthanized and the coronary vessels were perfusion-fixed with glutaraldehyde. The LAD vein was sectioned, and detailed morphometric measurements were made along its length from the point of ligation near the base down to the apex of the heart. The structural remodeling of the vein was circumferentially nonuniform because the vein is partially embedded in the myocardium; it was also axially nonuniform because it is tethered to the myocardium to different degrees along its axial length. The wall area was significantly larger in the experimental group, whereas luminal area in the proximal LAD vein was significantly smaller in the same group compared with sham-operated controls. The wall thickness-to-radius ratio was also significantly larger in the experimental group in proportion to the increase in pressure. The major conclusion of this study is that the response of the vein depends on the local wall stress, which is, in part, determined by the surrounding tissue. Furthermore, the geometric remodeling of the coronary vein restores the circumferential stress to the homeostatic value.
Insights into Penicillium roqueforti Morphological and Genetic Diversity
Gillot, Guillaume; Jany, Jean-Luc; Coton, Monika; Le Floch, Gaétan; Debaets, Stella; Ropars, Jeanne; López-Villavicencio, Manuela; Dupont, Joëlle; Branca, Antoine; Giraud, Tatiana; Coton, Emmanuel
2015-01-01
Fungi exhibit substantial morphological and genetic diversity, often associated with cryptic species differing in ecological niches. Penicillium roqueforti is used as a starter culture for blue-veined cheeses, being responsible for their flavor and color, but is also a common spoilage organism in various foods. Different types of blue-veined cheeses are manufactured and consumed worldwide, displaying specific organoleptic properties. These features may be due to the different manufacturing methods and/or to the specific P. roqueforti strains used. Substantial morphological diversity exists within P. roqueforti and, although not taxonomically valid, several technological names have been used for strains on different cheeses (e.g., P. gorgonzolae, P. stilton). A worldwide P. roqueforti collection from 120 individual blue-veined cheeses and 21 other substrates was analyzed here to determine (i) whether P. roqueforti is a complex of cryptic species, by applying the Genealogical Concordance Phylogenetic Species Recognition criterion (GC-PSR), (ii) whether the population structure assessed using microsatellite markers correspond to blue cheese types, and (iii) whether the genetic clusters display different morphologies. GC-PSR multi-locus sequence analyses showed no evidence of cryptic species. The population structure analysis using microsatellites revealed the existence of highly differentiated populations, corresponding to blue cheese types and with contrasted morphologies. This suggests that the population structure has been shaped by different cheese-making processes or that different populations were recruited for different cheese types. Cheese-making fungi thus constitute good models for studying fungal diversification under recent selection. PMID:26091176
Robust finger vein ROI localization based on flexible segmentation.
Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun
2013-10-24
Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.
Robust Finger Vein ROI Localization Based on Flexible Segmentation
Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun
2013-01-01
Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system. PMID:24284769
Sakurai, Katsunobu; Amano, Ryosuke; Yamamoto, Akira; Nishida, Norifumi; Matsutani, Shinya; Hirata, Keiichiro; Kimura, Kenjiro; Muguruma, Kazuya; Toyokawa, Takahiro; Kubo, Naoshi; Tanaka, Hiroaki; Yashiro, Masakazu; Ohira, Masaichi; Hirakawa, Kosei
2014-01-01
This report describes the successful use of portal venous stent placement for a patient with recurrent melena secondary to jejunal varices that developed after subtotal stomach preserved pancreatoduodenectomy (SSPPD). A 67-year-old man was admitted to our hospital with tarry stool and severe anemia at 2 years after SSPPD for carcinoma of the head of the pancreas. Abdominal computed tomography examination showed severe stenosis of the extrahepatic portal vein caused by local recurrence and showed an intensely enhanced jejunal wall at the choledochojejunostomy. Gastrointestinal bleeding scintigraphy also revealed active bleeding near the choledochojejunostomy. Based on these findings, jejunal varices resulting from portal vein stenosis were suspected as the cause of the melena. Portal vein stenting and balloon dilation was performed via the ileocecal vein after laparotomy. Coiling of the jejunal varices and sclerotherapy of the dilate postgastric vein with 5% ethanolamine oleate with iopamidol was performed. After portal stent placement, the patient was able to lead a normal life without gastrointestinal hemorrhage. However, he died 7 months later due to liver metastasis. PMID:24444277
Paty, Jean; Elash, Celeste A; Turner-Bowker, Diane M
2017-02-01
Varicose veins are common and can impact patients' quality of life, but consensus regarding the evaluation of varicose vein symptoms is lacking and existing measures have limitations. This research aimed to develop and establish the content validity of a new electronic patient-reported outcome (PRO) measure, the VVSymQ ® instrument, to assess symptoms of superficial venous insufficiency (varicose veins) in clinical trials. The development of the VVSymQ ® instrument began with qualitative interviews with patients based on the symptom domain of the VEINES-QOL/Sym, an existing PRO instrument for chronic venous disorders of the leg. Three phases of qualitative research were conducted to examine the relevance and importance of the symptoms to patients with varicose veins, and the patients' ability to understand and use the VVSymQ ® instrument. The development included evaluating questions that had 1-week and 24-h recall periods, and paper and electronic versions of the new instrument. Five symptoms (heaviness, achiness, swelling, throbbing, and itching [HASTI™]) were consistently reported by patients across all sources of qualitative data. The final version of the VVSymQ ® instrument queries patients on the HASTI™ symptoms using a 24-h recall period and a 6-point duration-based response scale ranging from "None of the time" to "All of the time," and is administered daily via an electronic diary. Cognitive interviews demonstrated varicose vein patients' understanding of and their ability to use the final version of the VVSymQ ® instrument. Content validity was established for the VVSymQ ® instrument, which assesses the five HASTI™ symptoms of varicose veins daily via an electronic diary and has promise for use in research and practice.
NASA Astrophysics Data System (ADS)
Kubač, Alexander; Chovan, Martin; Koděra, Peter; Kyle, J. Richard; Žitňan, Peter; Lexa, Jaroslav; Vojtko, Rastislav
2018-03-01
The Au-Ag-Pb-Zn-Cu epithermal deposit Banská Hodruša of intermediate-sulphidation type is located in the Middle Miocene Štiavnica stratovolcano on the inner side of the Carpathian arc in Slovakia. This deposit represents an unusual subhorizontal multi-stage vein system, related to processes of underground cauldron subsidence and exhumation of a subvolcanic granodiorite pluton. Veins are developed on a low-angle normal shear zone, possibly representing a detachment zone in andesitic wall rocks that formed during emplacement and exhumation of the granodiorite pluton. The deposit consists of two parts, separated by a thick sill of quartz-diorite porphyry. The eastern part is currently mined, and the western part has already been depleted. The Banská Hodruša mineralization was formed during four stages: (1) low-grade silicified breccia at subhorizontal structures at the base of the deposit; (2) stockwork of steep veins with rhodonite-rhodochrosite, quartz-sulphide-carbonate and quartz-gold assemblages; (3) thin quartz-gold veins with medium dip in tension cracks inside the shear zone and complementary detachment hosted quartz-base metals-gold veins; (4) Post-ore veins. Gold and electrum (920-730) occur as intergrowths with base metal sulphides or hosted in quartz and carbonates, accompanied by Au-Ag tellurides (hessite, petzite). Rare Te-polybasite and Cu-cervelleite result from re-equilibration of early Te-bearing minerals during cooling. Sulphide minerals include low Fe sphalerite ( 1.25 wt%), galena, chalcopyrite, and pyrite. The wall rock alteration is represented mostly by adularia, illite, chlorite, quartz, calcite and pyrite. Precipitation of gold, Au-Ag tellurides, Mn-bearing minerals and adularia resulted from boiling of fluids due to hydraulic fracturing, as well as opening of dilatational structures within the shear zone.
Zhang, He; Gonenc, Berk; Iordachita, Iulian
2017-10-01
Retinal vein occlusion is one of the most common retinovascular diseases. Retinal vein cannulation is a potentially effective treatment method for this condition that currently lies, however, at the limits of human capabilities. In this work, the aim is to use robotic systems and advanced instrumentation to alleviate these challenges, and assist the procedure via a human-robot collaborative mode based on our earlier work on the Steady-Hand Eye Robot and force-sensing instruments. An admittance control method is employed to stabilize the cannula relative to the vein and maintain it inside the lumen during the injection process. A pre-stress strategy is used to prevent the tip of microneedle from getting out of vein in in prolonged infusions, and the performance is verified through simulations.
Farr, Susan A; Erickson, Michelle A; Niehoff, Michael L; Banks, William A; Morley, John E
2014-01-01
Alzheimer's disease (AD) is a progressive neurodegenerative disease. Currently, there are no therapies to stop or reverse the symptoms of AD. We have developed an antisense oligonucleotide (OL-1) against the amyloid-β protein precursor (AβPP) that can decrease AβPP expression and amyloid-β protein (Aβ) production. This antisense rapidly crosses the blood-brain barrier, reverses learning and memory impairments, reduces oxidative stress, and restores brain-to-blood efflux of Aβ in SAMP8 mice. Here, we examined the effects of this AβPP antisense in the Tg2576 mouse model of AD. We administered the OL-1 antisense into the lateral ventricle 3 times at 2week intervals. Seventy-two hours after the third injection, we tested learning and memory in T-maze foot shock avoidance. In the second study, we injected the mice with OL-1 antisense 3 times at 2-week intervals via the tail vein. Seventy-two hours later, we tested learning and memory T-maze, novel object recognition, and elevated plus maze. At the end of behavioral testing, brain tissue was collected. OL-1 antisense administered centrally improved acquisition and retention of T-maze foot shock avoidance. OL-1 antisense administered via tail vein improved learning and memory in both T-maze foot shock avoidance and novel object-place recognition. In the elevated plus maze, the mice which received OL-1 antisense spent less time in the open arms and had fewer entries into the open arms indicating reduced disinhibitation. Biochemical analyses reveal significant reduction of AβPP signal and a reduction of measures of neuroinflammation. The current findings support the therapeutic potential of OL-1 AβPP antisense.
Leo, Moro; Stefano, Ricci; Raffaele, Antonelli Incalzi
2018-06-01
Objective Ultrasound-guided foam sclerotherapy (UGFS) - one of the most frequently recommended methods for treating great saphenous vein incompetence - is easy and inexpensive. However, it achieves a lower occlusion rate compared to endovenous thermal ablation. The application of UGFS to pre-terminal great saphenous vein interruption, eliminating the saphenous stem wash out effect, enhances the short-term occlusion rate. This study explores the results of this technique at 12 months. Method Thirty great saphenous veins (28 patients) with junction incompetence, with calibres >6 mm and >30 cm reflux stem length were submitted to echo-guided pre-terminal great saphenous vein interruption and foam great saphenous vein occlusion. Participants were subjected to a 12-month post-operative review by ultrasound assessment of great saphenous vein occlusion and terminal stump stability. Comparisons were made between pre-operative and 12-month Validation of Venous Clinical Severity Score (VCSS), photopletismography, Aberdeen questionnaire and complications. Results After 12 months, 28/30 great saphenous veins remained occluded (93%). One complete and one partial recanalization did not require retreatment. Four saphenous stumps showed a reflux during Valsalva (one due to recanalization, one limited to the stump, two with reflux in the anterior accessory saphenous vein). VCSS improved from 3.33 ± 1.64 to 0.67 ± 1.21 ( p < 0.05). Aberdeen questionnaire scores decreased from 9.44 ± 6.18 to 2.47 ± 3.77 ( p < 0.05). For photopletismographic examination, the mean venous refilling time (normal value: > 25 s) improved from 17.94 ± 11.97 to 31.4 ± 11.99 ( p < 0.05). Conclusion Applying pre-terminal great saphenous vein interruption to UGFS of the saphenous stem achieved an occlusion rate at one year similar to that of endovenous thermal ablation. The procedure is simple, effective, office based, and may be used as a 10-min prolongation to a phlebectomy.
Hayba, D.O.
1997-01-01
Detailed fluid inclusion studies on coarse-grained sphalerite from the OH vein, Creede, Colorado, have shown that the abrupt color changes between growth zones correspond to abrupt changes in the nature of the ore fluids. Within each growth zone, however, the composition of the fluids remained constant. The base of a distinctive orange-brown growth zone marks a sharp increase in both temperature and salinity relative to the preceding yellow-white zone. The orange-brown growth zone can be correlated along much of the vein and is believed to represent a time-stratigraphic interval. Along the vein, temperatures and salinities of fluid inclusions within this interval show a systematic decrease from about 285??C and 11.5 wt percent NaCl equiv near the base of the vein to about 250??C and 8 wt percent NaCl equiv, respectively, near the top of the vein. The iron concentration of this sphalerite growth zone shows a similar pattern, decreasing from about 2.8 to 1.2 mole percent FeS. When plotted on an enthalpy-salinity diagram, the fluid inclusion data define a spatial trend indicating the progressive mixing of deeply circulating hydrothermal brines with overlying, dilute ground waters. The hydrothermal brines entered the OH vein from below at a temperature, salinity, and density of approximately 285??C, 11.5 wt percent NaCl equiv, and 860 kg/m3, respectively, whereas the overlying ground waters appear to have been preheated to roughly 150??C and had an assumed salinity of 0 wt percent and a density of 920 kg/m3. The greater density of the heated ground water promoted mixing with the hydrothermal brine within the open fractures, causing sphalerite deposition. Although there were also episodes of boiling during vein mineralization, boiling appears unimportant for this sphalerite. Isotopic evidence and geochemical modeling studies also indicate that mixing was the depositional mechanism for sphalerite. An important aspect of the mixing hydrology of the Creede system involves an aquitard overlying the OH vein. This low permeability zone restricted the flow of ground water into the vein from above and forced the upwelling hydrothermal fluids to flow laterally along the vein. The mixing environment thus occurred along the interface between a deeply circulating hydrothermal convection cell and a topographically driven shallow ground-water system.
Tóth, Zsuzsanna; Nagy-Baló, Edina; Kertész, Attila; Clemens, Marcell; Herczku, Csaba; Tint, Diana; Kun, Csaba; Edes, István; Csanádi, Zoltán
2010-01-31
Several transcatheter techniques based on radiofrequency energy were elaborated for the treatment of atrial fibrillation through the last decade. Recently, similar success rates with a better safety profile concerning life threatening complications were reported with the novel methode of cryoballon isolation of the pulmonary veins. This paper summarizes our initial experience with cryoballon ablation after the first 55 patients. [corrected] Symptomatic patients refractory to aniarrhythmic medication mostly with paroxysmal atrial fibrillation without significant structural heart disease were enrolled. Cannulation and isolation of all pulmonary veins were attempted using a 28 mm double-wall cryoballon inflated at the ostium of the vein and abolishing eletrical activity of atrial tissue around its perimeter by freezing to -70 C. Intravenous heparin during and oral anticoagulant after the procedure was administered. Conventional ECGs, Holter ECGs and transtelephonic ECG recordings were used through 6 months follow-up for rhythm monitoring. In 55 patients enrolled (18 female; age: 56 + or - 33,64 years) 165 out ot 192 (86%) pulmonary veins were successfully isolated. All pulmonary veins were isolated in 37 patients (67%). Procedure time was 155.67 + or - 100.66 min, while fluoroscopy time was 34.04 + or - 31.89 min. In 34 patients with 6 months follow-up 24 (70%) either remained free of arrhythmia (17 patients) or had a significant decrease in arrhythmia burden (7 patients). Based on our initial experience, cryoballon isolation of pulmonary veins appears to be a more simple procedure with similar efficacy to radiofrequency ablation in the treatment of atrial fibrillation.
Tinder, Chelsey N; Chavanpun, Joe P; Bandyk, Dennis F; Armstrong, Paul A; Back, Martin R; Johnson, Brad L; Shames, Murray L
2008-09-01
Controversy regarding the efficacy of duplex ultrasound surveillance after infrainguinal vein bypass led to an analysis of patient and bypass graft characteristics predictive for development of graft stenosis and a decision of secondary intervention. Retrospective analysis of a contemporary, consecutive series of 353 clinically successful infrainguinal vein bypasses performed in 329 patients for critical (n = 284; 80%) or noncritical (n = 69; 20%) limb ischemia enrolled in a surveillance program to identify and repair duplex-detected graft stenosis. Variables correlated with graft stenosis and bypass repair included: procedure indication, conduit type (saphenous vs nonsaphenous vein; reversed vs nonreversed orientation), prior bypass graft failure, postoperative ankle-brachial index (ABI) < 0.85, and interpretation of the first duplex surveillance study as "normal" or "abnormal" based on peak systolic velocity (PSV) and velocity ratio (Vr) criteria. Overall, 126 (36%) of the 353 infrainguinal bypasses had 174 secondary interventions (endovascular, 100; surgery, 74) based on duplex surveillance; resulting in 3-year Kaplan-Meier primary (46%), assisted-primary (80%), and secondary (81%) patency rates. Characteristics predictive of duplex-detected stenosis leading to intervention (PSV: 443 +/- 94 cm/s; Vr: 8.6 +/- 9) were: "abnormal" initial duplex testing indicating moderate (PSV: 180-300 cm/s, Vr: 2-3.5) stenosis (P < .0001), non-single segment saphenous vein conduit (P < .01), warfarin drug therapy (P < .01), and redo bypass grafting (P < .001). Procedure indication, postoperative ABI level, statin drug therapy, and vein conduit orientation were not predictive of graft revision. The natural history of 141 (40%) bypasses with an abnormal first duplex scan differed from "normal" grafts by more frequent (51% vs 24%, P < .001) and earlier (7 months vs 11 months) graft revision for severe stenosis and a lower 3-year assisted primary patency (68% vs 87%; P < .001). In 52 (15%) limbs, the bypass graft failed and 20 (6%) limbs required amputation. The efficacy of duplex surveillance after infrainguinal vein bypass may be enhanced by modifying testing protocols, eg, rigorous surveillance for "higher risk" bypasses, based on the initial duplex scan results and other characteristics (warfarin therapy, non- single segment saphenous vein conduit, redo bypass) predictive for stenosis development.
NASA Astrophysics Data System (ADS)
Dewaele, S.; De Clercq, F.; Hulsbosch, N.; Piessens, K.; Boyce, A.; Burgess, R.; Muchez, Ph.
2016-02-01
The vein-type tungsten deposit at Nyakabingo in the central Tungsten belt of Rwanda is located in the eastern flank of the complex Bumbogo anticlinal structure. The host rock is composed of alternating sequences of sandstones, quartzites, and black pyritiferous metapelitic rocks. Two types of W-mineralized quartz veins have been observed: bedding-parallel and quartz veins that are at high angle to the bedding, which are termed crosscutting veins. Both vein types have been interpreted to have been formed in a late stage of a compressional deformation event. Both vein types are associated with small alteration zones, comprising silicification, tourmalinization, and muscovitization. Dating of muscovite crystals at the border of the veins resulted in a maximum age of 992.4 ± 1.5 Ma. This age is within error similar to the ages obtained for the specialized G4 granites (i.e., 986 ± 10 Ma). The W-bearing minerals formed during two different phases. The first phase is characterized by scheelite and massive wolframite, while the second phase is formed by ferberite pseudomorphs after scheelite. These minerals occur late in the evolution of the massive quartz veins, sometimes even in fractures that crosscut the veins. The ore minerals precipitated from a H2O-CO2-CH4-N2-NaCl-(KCl) fluid with low to moderate salinity (0.6-13.8 eq. wt% NaCl), and minimal trapping temperatures between 247 and 344 °C. The quartz veins have been crosscut by sulfide-rich veins. Based on the similar setting, mineralogy, stable isotope, and fluid composition, it is considered that both types of W-mineralized quartz veins formed during the same mineralizing event. Given the overlap in age between the G4 granites and the mineralized quartz veins, and the typical association of the W deposits in Rwanda, but also worldwide, with granite intrusions, W originated from the geochemically specialized G4 granites. Intense water-rock interaction and mixing with metamorphic fluids largely overprinted the original magmatic-hydrothermal signature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinberg, M.I.; Wiest, S.A.; Zimmerman, K.M.
1991-01-01
Pinacidil, a potassium channel opener (PCO), relaxes vascular smooth muscle by increasing potassium ion membrane conductance, thereby causing membrane hyperpolarization. PCOs also act on cardiac muscle to decrease action potential duration (APD) selectively. To examine the enantiomeric selectivity of pinacidil, the stereoisomers of pinacidil (a 4-pyridylcyanoguanidine) and its 3-pyridyl isomer (LY222675) were synthesized and studied in canine Purkinje fibers and cephalic veins. The (-)-enantiomers of both pinacidil and LY222675 were more potent in relaxing phenylephrine-contracted cephalic veins and decreasing APD than were their corresponding (+)-enantiomers. The EC50 values for (-)-pinacidil and (-)-LY222675 in relaxing cephalic veins were 0.44 and 0.09more » microM, respectively. In decreasing APD, the EC50 values were 3.2 microM for (-)-pinacidil and 0.43 microM for (-)-LY222675. The eudismic ratio was greater for the 3-pyridyl isomer than for pinacidil in both cardiac (71 vs. 22) and vascular (53 vs. 17) tissues. (-)-LY222675 and (-)-pinacidil (0.1-30 microM) also increased 86Rb efflux from cephalic veins to a greater extent than did their respective optical antipodes. The antidiabetic sulfonylurea, glyburide (1-30 microM), shifted the vascular concentration-response curve of (-)-pinacidil to the right by a similar extent at each inhibitor concentration. Glipizide also antagonized the response to (-)-pinacidil, but was about 1/10 as potent with a maximal shift occurring at 10 and 30 microM. Glyburide antagonized the vascular relaxant effects of 0.3 microM (-)-LY222675 (EC50, 2.3 microM) and reversed the decrease in APD caused by 3 microM (-)-LY222675 (EC50, 1.9 microM). Nitroprusside did not alter 86Rb efflux, and vascular relaxation induced by sodium nitroprusside was unaffected by sulfonylureas.« less
Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo; Van Alstine, William; Binkert, Christoph A; Klausen, Kasper
2017-01-01
This study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo. A diamond-shaped stent-base was cut from a sequential biaxially strained poly(L-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively. In vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks. A bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Løvdal, Alexandra Liv Vest, E-mail: alvlo@nanotech.dtu.dk; Calve, Sarah; Yang, Shuo
PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed anmore » elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.« less
2014-01-01
Background Recently it was shown that retinal vessel diameters could be measured using spectral domain optical coherence tomography (OCT). It has also been suggested that retinal vessels manifest different features on spectral domain OCT (SD-OCT) depending on whether they are arteries or veins. Our study was aimed to present a reliable SD-OCT assisted method of differentiating retinal arteries from veins. Methods Patients who underwent circular OCT scans centred at the optic disc using a Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany) were retrospectively reviewed. Individual retinal vessels were identified on infrared reflectance (IR) images and given unique labels for subsequent grading. Vessel types (artery, vein or uncertain) assessed by IR and/or fluorescein angiography (FA) were referenced as ground truth. From OCT, presence/absence of the hyperreflective lower border reflectivity feature was assessed. Presence of this feature was considered indicative for retinal arteries and compared with the ground truth. Results A total of 452 vessels from 26 eyes of 18 patients were labelled and 398 with documented vessel type (302 by IR and 96 by FA only) were included in the study. Using SD-OCT, 338 vessels were assigned a final grade, of which, 86.4% (292 vessels) were classified correctly. Forty three vessels (15 arteries and 28 veins) that IR failed to differentiate were correctly classified by SD-OCT. When using only IR based ground truth for vessel type the SD-OCT based classification approach reached a sensitivity of 0.8758/0.9297, and a specificity of 0.9297/0.8758 for arteries/veins, respectively. Conclusion Our method was able to classify retinal arteries and veins with a commercially available SD-OCT alone, and achieved high classification performance. Paired with OCT based vessel measurements, our study has expanded the potential clinical implication of SD-OCT in evaluation of a variety of retinal and systemic vascular diseases. PMID:24884611
Superior ophthalmic vein enlargement and increased muscle index in dysthyroid optic neuropathy.
Lima, Breno da Rocha; Perry, Julian D
2013-01-01
To compare superior ophthalmic vein diameter and extraocular muscle index in patients with thyroid eye disease with or without optic neuropathy. High-resolution CT scan images of 40 orbits of 20 patients with history of thyroid eye disease (with or without optic neuropathy), who underwent orbital decompression surgery from January 2007 to November 2009, were retrospectively reviewed. Superior ophthalmic vein diameter was measured in coronal and axial planes. Extraocular muscle index was calculated according to the method proposed by Barrett et al. The clinical diagnosis of optic neuropathy was based on characteristic signs that included afferent pupillary defect, decreased visual acuity, visual field defects, and dyschromatopsia. Orbits were divided in 2 groups based on presence or absence of optic neuropathy. Superior ophthalmic vein diameter was significantly higher in orbits with concomitant optic neuropathy (mean 2.4 ± 0.4mm, p < 0.0001). Increased muscle index was also related to optic neuropathy (mean 57.9% ± 5.7%, p = 0.0002). Muscle index greater than 50% was present in all patients with dysthyroid optic neuropathy. This study suggests that patients with thyroid eye disease with enlarged superior ophthalmic vein and increased extraocular muscle index are more likely to have concomitant optic neuropathy.
Hayashi, Shogo; Naito, Munekazu; Hirai, Shuichi; Terayama, Hayato; Miyaki, Takayoshi; Itoh, Masahiro; Fukuzawa, Yoshitaka; Nakano, Takashi
2013-09-01
There are many reports on variations in the inferior vena cava (IVC), particularly double IVC (DIVC) and left IVC (LIVC). However, no systematic report has recorded iliac vein (IV) flow patterns in the DIVC and LIVC. In this study, we examined IV flow patterns in both DIVC and LIVC observed during gross anatomy courses conducted for medical students and in previously reported cases. During the gross anatomy courses, three cases of DIVC and one case of LIVC were found in 618 cadavers. The IV flow pattern from these four cases and all other previously reported cases can be classified into one of the following three types according to the vein into which the internal iliac vein drained: the ipsilateral external IV; confluence of the ipsilateral external IV and IVC; and the communicating vein, which connects the IVC and the contralateral IVC or its iliac branch. This classification, which is based on the internal IV course, is considered to be useful because IV variations have the potential to cause clinical problems during related retroperitoneal surgery, venous interventional radiology, and diagnostic procedures for pelvic cancer.
Does acid-base equilibrium correlate with remnant liver volume during stepwise liver resection?
Golriz, Mohammad; Abbasi, Sepehr; Fathi, Parham; Majlesara, Ali; Brenner, Thorsten; Mehrabi, Arianeb
2017-10-01
Small for size and flow syndrome (SFSF) is one of the most challenging complications following extended hepatectomy (EH). After EH, hepatic artery flow decreases and portal vein flow increases per 100 g of remnant liver volume (RLV). This causes hypoxia followed by metabolic acidosis. A correlation between acidosis and posthepatectomy liver failure has been postulated but not studied systematically in a large animal model or clinical setting. In our study, we performed stepwise liver resections on nine pigs to defined SFSF limits as follows: step 1: segment II/III resection, step 2: segment IV resection, step 3: segment V/VIII resection (RLV: 75, 50, and 25%, respectively). Blood gas values were measured before and after each step using four catheters inserted into the carotid artery, internal jugular vein, hepatic artery, and portal vein. The pH, [Formula: see text], and base excess (BE) decreased, but [Formula: see text] values increased after 75% resection in the portal and jugular veins. EH correlated with reduced BE in the hepatic artery. Pco 2 values increased after 75% resection in the jugular vein. In contrast, arterial Po 2 increased after every resection, whereas the venous Po 2 decreased slightly. There were differences in venous [Formula: see text], BE in the hepatic artery, and Pco 2 in the jugular vein after 75% liver resection. Because 75% resection is the limit for SFSF, these noninvasive blood evaluations may be used to predict SFSF. Further studies with long-term follow-up are required to validate this correlation. NEW & NOTEWORTHY This is the first study to evaluate acid-base parameters in major central and hepatic vessels during stepwise liver resection. The pH, [Formula: see text], and base excess (BE) decreased, but [Formula: see text] values increased after 75% resection in the portal and jugular veins. Extended hepatectomy correlated with reduced BE in the hepatic artery. Because 75% resection is the limit for small for size and flow syndrome (SFSF), postresection blood gas evaluations may be used to predict SFSF. Copyright © 2017 the American Physiological Society.
Jonas, Jost B; Wang, Ningli; Wang, Shuang; Wang, Ya Xing; You, Qi Sheng; Yang, Diya; Wei, Wen Bin; Xu, Liang
2014-09-01
Hypertensive retinal microvascular abnormalities include an increased retinal vein-to-artery diameter ratio. Because central retinal vein pressure depends on cerebrospinal fluid pressure (CSFP), we examined whether the retinal vein-to-artery diameter ratio and other retinal hypertensive signs are associated with CSFP. Participants of the population-based Beijing Eye Study (n = 1,574 subjects) underwent measurement of the temporal inferior and superior retinal artery and vein diameter. CSFP was calculated as 0.44 × body mass index (kg/m(2)) + 0.16 × diastolic blood pressure (mm Hg) - 0.18 × age (years) - 1.91. Larger retinal vein diameters and higher vein-to-artery diameter ratios were significantly associated with higher estimated CSFP (P = 0.001) in multivariable analysis. In contrast, temporal inferior retinal arterial diameter was marginally associated (P = 0.03) with estimated CSFP, and temporal superior artery diameter was not significantly associated (P = 0.10) with estimated CSFP; other microvascular abnormalities, such as arteriovenous crossing signs, were also not significantly associated with estimated CSFP. In a reverse manner, higher estimated CSFP as a dependent variable in the multivariable analysis was associated with wider retinal veins and higher vein-to-artery diameter ratio. In the same model, estimated CSFP was not significantly correlated with retinal artery diameters or other retinal microvascular abnormalities. Correspondingly, arterial hypertension was associated with retinal microvascular abnormalities such as arteriovenous crossing signs (P = 0.003), thinner temporal retinal arteries (P < 0.001), higher CSFP (P < 0.001), and wider retinal veins (P = 0.001) or, as a corollary, with a higher vein-to-artery diameter ratio in multivariable analysis. Wider retinal vein diameters are associated with higher estimated CSFP and vice versa. In arterial hypertension, an increased retinal vein-to-artery diameter ratio depends on elevated CSFP, which is correlated with blood pressure. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
SWI enhances vein detection using gadolinium in multiple sclerosis
Mazzoni, Lorenzo N; Moretti, Marco; Grammatico, Matteo; Chiti, Stefano; Massacesi, Luca
2015-01-01
Susceptibility weighted imaging (SWI) combined with the FLAIR sequence provides the ability to depict in vivo the perivenous location of inflammatory demyelinating lesions – one of the most specific pathologic features of multiple sclerosis (MS). In addition, in MS white matter (WM) lesions, gadolinium-based contrast media (CM) can increase vein signal loss on SWI. This report focuses on two cases of WM inflammatory lesions enhancing on SWI images after CM injection. In these lesions in fact the CM increased the contrast between the parenchyma and the central vein allowing as well, in one of the two cases, the detection of a vein not visible on the same SWI sequence acquired before CM injection. PMID:25815209
Hwang, Shin; Ha, Tae-Yong; Ahn, Chul-Soo; Moon, Deok-Bog; Kim, Ki-Hun; Song, Gi-Won; Jung, Dong-Hwan; Park, Gil-Chun; Lee, Sung-Gyu
2016-08-01
After having experienced more than 2,000 cases of adult living donor liver transplantation (LDLT), we established the concepts of right liver graft standardization. Right liver graft standardization intends to provide hemodynamics-based and regeneration-compliant reconstruction of vascular inflow and outflow. Right liver graft standardization consists of the following components: Right hepatic vein reconstruction includes a combination of caudal-side deep incision and patch venoplasty of the graft right hepatic vein to remove the acute angle between the graft right hepatic vein and the inferior vena cava; middle hepatic vein reconstruction includes interposition of a uniform-shaped conduit with large-sized homologous or prosthetic grafts; if the inferior right hepatic vein is present, its reconstruction includes funneling and unification venoplasty for multiple short hepatic veins; if donor portal vein anomaly is present, its reconstruction includes conjoined unification venoplasty for two or more portal vein orifices. This video clip that shows the surgical technique from bench to reperfusion was a case presentation of adult LDLT using a modified right liver graft from the patient's son. Our intention behind proposing the concept of right liver graft standardization is that it can be universally applicable and may guarantee nearly the same outcomes regardless of the surgeon's experience. We believe that this reconstruction model would be primarily applied to a majority of adult LDLT cases.
Yamamoto, Shingo; Tanooka, Masao; Ando, Kumiko; Yamano, Toshiko; Ishikura, Reiichi; Nojima, Michio; Hirota, Shozo; Shima, Hiroki
2009-12-01
To evaluate the diagnostic accuracy of computed tomography (CT)-based imaging methods for assessing renal vascular anatomy, imaging studies, including standard axial CT, three-dimensional volume-rendered CT (3DVR-CT), and a 3DVR-CT movie, were performed on 30 patients who underwent laparoscopic donor nephrectomy (10 right side, 20 left side) for predicting the location of the renal arteries and renal, adrenal, gonadal, and lumbar veins. These findings were compared with videos obtained during the operation. Two of 37 renal arteries observed intraoperatively were missed by standard axial CT and 3DVR-CT, whereas all arteries were identified by the 3DVR-CT movie. Two of 36 renal veins were missed by standard axial CT and 3DVR-CT, whereas 1 was missed by the 3DVR-CT movie. In 20 left renal hilar anatomical structures, 20 adrenal, 20 gonadal, and 22 lumbar veins were observed during the operation. Preoperatively, the standard axial CT, 3DVR-CT, and 3DVR-CT movie detected 11, 19, and 20 adrenal veins; 13, 14, and 19 gonadal veins; and 6, 11, and 15 lumbar veins, respectively. Overall, of 135 renal vascular structures, the standard axial CT, 3DVR-CT, and 3DVR-CT movie accurately detected 99 (73.3%), 113 (83.7%), and 126 (93.3%) vessels, respectively, which indicated that the 3DVR-CT movie demonstrated a significantly higher detection rate than other CT-based imaging methods (P < 0.05). The 3DVR-CT movie accurately provides essential information about the renal vascular anatomy before laparoscopic donor nephrectomy.
How do leaf veins influence the worldwide leaf economic spectrum? Review and synthesis.
Sack, Lawren; Scoffoni, Christine; John, Grace P; Poorter, Hendrik; Mason, Chase M; Mendez-Alonzo, Rodrigo; Donovan, Lisa A
2013-10-01
Leaf vein traits are implicated in the determination of gas exchange rates and plant performance. These traits are increasingly considered as causal factors affecting the 'leaf economic spectrum' (LES), which includes the light-saturated rate of photosynthesis, dark respiration, foliar nitrogen concentration, leaf dry mass per area (LMA) and leaf longevity. This article reviews the support for two contrasting hypotheses regarding a key vein trait, vein length per unit leaf area (VLA). Recently, Blonder et al. (2011, 2013) proposed that vein traits, including VLA, can be described as the 'origin' of the LES by structurally determining LMA and leaf thickness, and thereby vein traits would predict LES traits according to specific equations. Careful re-examination of leaf anatomy, published datasets, and a newly compiled global database for diverse species did not support the 'vein origin' hypothesis, and moreover showed that the apparent power of those equations to predict LES traits arose from circularity. This review provides a 'flux trait network' hypothesis for the effects of vein traits on the LES and on plant performance, based on a synthesis of the previous literature. According to this hypothesis, VLA, while virtually independent of LMA, strongly influences hydraulic conductance, and thus stomatal conductance and photosynthetic rate. We also review (i) the specific physiological roles of VLA; (ii) the role of leaf major veins in influencing LES traits; and (iii) the role of VLA in determining photosynthetic rate per leaf dry mass and plant relative growth rate. A clear understanding of leaf vein traits provides a new perspective on plant function independently of the LES and can enhance the ability to explain and predict whole plant performance under dynamic conditions, with applications towards breeding improved crop varieties.
Neurological sequelae from brachiocephalic vein stenosis.
Herzig, David W; Stemer, Andrew B; Bell, Randy S; Liu, Ai-Hsi; Armonda, Rocco A; Bank, William O
2013-05-01
Stenosis of central veins (brachiocephalic vein [BCV] and superior vena cava) occurs in 30% of hemodialysis patients, rarely producing intracranial pathology. The authors present the first cases of BCV stenosis causing perimesencephalic subarachnoid hemorrhage and myoclonic epilepsy. In the first case, a 73-year-old man on hemodialysis presented with headache and blurry vision, and was admitted with presumed idiopathic intracranial hypertension after negative CT studies and confirmatory lumbar puncture. The patient mildly improved until hospital Day 3, when he experienced a seizure; emergency CT scans showed perimesencephalic subarachnoid hemorrhage. Cerebral angiography failed to find any vascular abnormality, but demonstrated venous congestion. A fistulogram found left BCV occlusion with jugular reflux. The occlusion could not be reopened percutaneously and required open fistula ligation. Postoperatively, symptoms resolved and the patient remained intact at 7-month follow-up. In the second case, a 67-year-old woman on hemodialysis presented with right arm weakness and myoclonic jerks. Admission MRI revealed subcortical edema and a possible dural arteriovenous fistula. Cerebral angiography showed venous engorgement, but no vascular malformation. A fistulogram found left BCV stenosis with jugular reflux, which was immediately reversed with angioplasty and stent placement. Postprocedure the patient was seizure free, and her strength improved. Seven months later the patient presented in myoclonic status epilepticus, and a fistulogram revealed stent occlusion. Angioplasty successfully reopened the stent and she returned to baseline; she was seizure free at 4-month follow-up. Central venous stenosis is common with hemodialysis, but rarely presents with neurological findings. Prompt recognition and endovascular intervention can restore normal venous drainage and resolve symptoms.
Kishino, Mitsuhiro; Yoshimoto, Takanobu; Nakadate, Masashi; Katada, Yoshiaki; Kanda, Eiichiro; Nakaminato, Shuichiro; Saida, Yukihisa; Ogawa, Yoshihiro; Tateishi, Ukihide
2017-03-31
We evaluated the influence of catheter sampling position and size on left adrenal venous sampling (AVS) in patients with primary aldosteronism (PA) and analyzed their relationship to cortisol secretion. This retrospective study included 111 patients with a diagnosis of primary aldosteronism who underwent tetracosactide-stimulated AVS. Left AVS was obtained from two catheter positions - the central adrenal vein (CAV) and the common trunk. For common trunk sampling, 5-French catheters were used in 51 patients, and microcatheters were used in 60 patients. Autonomous cortisol secretion was evaluated with a low-dose dexamethasone suppression test in 87 patients. The adrenal/inferior vena cava cortisol concentration ratio [selectivity index (SI)] was significantly lower in samples from the left common trunk than those of the left CAV and right adrenal veins, but this difference was reduced when a microcatheter was used for common trunk sampling. Sample dilution in the common trunk of the left adrenal vein can be decreased by limiting sampling speed with the use of a microcatheter. Meanwhile, there was no significant difference in SI between the left CAV and right adrenal veins. Laterality, determined according to aldosterone/cortisol ratio (A/C ratio) based criteria, showed good reproducibility regardless of sampling position, unlike the absolute aldosterone value based criteria. However, in 11 cases with autonomous cortisol co-secretion, the cortisol hypersecreting side tended to be underestimated when using A/C ratio based criteria. Left CAV sampling enables symmetrical sampling, and may be essential when using absolute aldosterone value based criteria in cases where symmetrical cortisol secretion is uncertain.
NASA Astrophysics Data System (ADS)
Katrašnik, Jaka; Bürmen, Miran; Pernuš, Franjo; Likar, Boštjan
2009-02-01
Visualization of subcutaneous veins is very difficult with the naked eye, but important for diagnosis of medical conditions and different medical procedures such as catheter insertion and blood withdrawal. Moreover, recent studies showed that the images of subcutaneous veins could be used for biometric identification. The majority of methods used for enhancing the contrast between the subcutaneous veins and surrounding tissue are based on simple imaging systems utilizing CMOS or CCD cameras with LED illumination capable of acquiring images from the near infrared spectral region, usually near 900 nm. However, such simplified imaging methods cannot exploit the full potential of the spectral information. In this paper, a new highly versatile method for enhancing the contrast of subcutaneous veins based on state-of-the-art high-resolution hyper-spectral imaging system utilizing the spectral region from 550 to 1700 nm is presented. First, a detailed analysis of the contrast between the subcutaneous veins and the surrounding tissue as a function of wavelength, for several different positions on the human arm, was performed in order to extract the spectral regions with the highest contrast. The highest contrast images were acquired at 1100 nm, however, combining the individual images from the extracted spectral regions by the proposed contrast enhancement method resulted in a single image with up to ten-fold better contrast. Therefore, the proposed method has proved to be a useful tool for visualization of subcutaneous veins.
Lu, Hai-Lin; Guo, Min; Liao, Yue-Kui; Huang, Ding-Ying; Huang, Chun-Ni; Wu, Xiao-Chen; He, Bao-Zuo
2012-11-01
To study the identification characters of Houttuynia cordata and its confused herb Gymnotheca chinensis and establish an identification method. LMVP (leaf morphological-venation pattern for identification Chinese herbs), and QAERM (quantitatively analyze and evaluate reliability for the method of identification Chinese herbs) were applied for the study. Both venations were brochidodromous-acrodromous and arising from the mid-petiole or the upper section of petiole. The main characteristic of the leaf of Houttuynia cordata: surface with small gray-white stoma protuberances; Ligulate process of stipule-petiole sheath were clear; Primary veins 7 or 5; The innermost pair of primary vein closed up the top of the sinus at blade base or above sinus, and the section of closed vein was straight; Emitted a smell of fish when fresh leaf was kneaded into pieces. The main feature of the leaf of Gymnotheca chinensis: no small gray-white stoma protuberances; Ligulate process of stipule-petiole sheath were not clear; Primary veins 5; The innermost pair of primary vein closed into the sinus at blade base, and the section of closed vein was slightly curve; No smell of fish. With the mentioned key differences, the both plants could be successfully identified from each other. The accuracy of identification results (AC) was 100%, the repeatability of identification results: agreement rate for observation (ARO) was 100% and Kappa value was 1.00. The established method is simple, rapid, economic and reliable.
Detection of Hypertension Retinopathy Using Deep Learning and Boltzmann Machines
NASA Astrophysics Data System (ADS)
Triwijoyo, B. K.; Pradipto, Y. D.
2017-01-01
hypertensive retinopathy (HR) in the retina of the eye is disturbance caused by high blood pressure disease, where there is a systemic change of arterial in the blood vessels of the retina. Most heart attacks occur in patients caused by high blood pressure symptoms of undiagnosed. Hypertensive retinopathy Symptoms such as arteriolar narrowing, retinal haemorrhage and cotton wool spots. Based on this reasons, the early diagnosis of the symptoms of hypertensive retinopathy is very urgent to aim the prevention and treatment more accurate. This research aims to develop a system for early detection of hypertension retinopathy stage. The proposed method is to determine the combined features artery and vein diameter ratio (AVR) as well as changes position with Optic Disk (OD) in retinal images to review the classification of hypertensive retinopathy using Deep Neural Networks (DNN) and Boltzmann Machines approach. We choose this approach of because based on previous research DNN models were more accurate in the image pattern recognition, whereas Boltzmann machines selected because It requires speedy iteration in the process of learning neural network. The expected results from this research are designed a prototype system early detection of hypertensive retinopathy stage and analysed the effectiveness and accuracy of the proposed methods.
Schwarzwald, Colin C; Jenni, Rolf
2009-01-01
Background Natural heterologous valved conduits with a diameter greater than 22 mm that can be used for right ventricular outflow tract reconstruction in adults are not commercially available. The purpose of this study was to measure by ultrasonography the maximum diameter of the distended jugular veins of horses and cattle, respectively, to identify a population of animals that would be suitable for post-mortem collection of jugular veins at sizes greater than 22 mm. Methods The study population included 60 Warmblood horses, 25 Freiberger horses, 20 Brown Swiss cows, and 20 Holstein cows (including 10 Holstein and 10 Red Holstein). The maximum cross-sectional diameter of the distended jugular veins was measured at a location half-way between the mandibular angle and the thoracic inlet. The thoracic circumference (heart girth length) was used as a surrogate of body size. The jugular vein diameters of the different populations were compared by analysis of variance and the association between heart girth length and jugular vein diameter was determined in each of the four study populations by linear regression analysis. Results There was considerable individual variation of jugular vein diameters within each of the four study populations. There was no statistically significant relationship between thoracic circumference and jugular vein diameter in any of the populations. The jugular vein diameters of Brown Swiss cows were significantly larger than those of any of the other populations. Warmblood horses had significantly larger jugular vein diameters compared to Freiberger horses. Conclusion The results of this study suggest that the production of bovine or equine xenografts with diameters of greater than 22 mm would be feasible. Differences between species and breeds need to be considered. However, prediction of the jugular vein diameter based on breed and heart girth length in an individual animal is inaccurate. PMID:19678940
Modeling frictional melt injection to constrain coseismic physical conditions
NASA Astrophysics Data System (ADS)
Sawyer, William J.; Resor, Phillip G.
2017-07-01
Pseudotachylyte, a fault rock formed through coseismic frictional melting, provides an important record of coseismic mechanics. In particular, injection veins formed at a high angle to the fault surface have been used to estimate rupture directivity, velocity, pulse length, stress drop, as well as slip weakening distance and wall rock stiffness. These studies have generally treated injection vein formation as a purely elastic process and have assumed that processes of melt generation, transport, and solidification have little influence on the final vein geometry. Using a pressurized crack model, an analytical approximation of injection vein formation based on dike intrusion, we find that the timescales of quenching and flow propagation may be similar for a subset of injection veins compiled from the Asbestos Mountain Fault, USA, Gole Larghe Fault Zone, Italy, and the Fort Foster Brittle Zone, USA under minimum melt temperature conditions. 34% of the veins are found to be flow limited, with a final geometry that may reflect cooling of the vein before it reaches an elastic equilibrium with the wall rock. Formation of these veins is a dynamic process whose behavior is not fully captured by the analytical approach. To assess the applicability of simplifying assumptions of the pressurized crack we employ a time-dependent finite-element model of injection vein formation that couples elastic deformation of the wall rock with the fluid dynamics and heat transfer of the frictional melt. This finite element model reveals that two basic assumptions of the pressurized crack model, self-similar growth and a uniform pressure gradient, are false. The pressurized crack model thus underestimates flow propagation time by 2-3 orders of magnitude. Flow limiting may therefore occur under a wider range of conditions than previously thought. Flow-limited veins may be recognizable in the field where veins have tapered profiles or smaller aspect ratios than expected. The occurrence and shape of injection veins can be coupled with modeling to provide an independent estimate of minimum melt temperature. Finally, the large aspect ratio observed for all three populations of injection veins may be best explained by a large reduction in stiffness associated with coseismic damage, as injection vein growth is likely to far exceed the lifetime of dynamic stresses at any location along a fault.
Drew, L.J.
2003-01-01
A tectonic model useful in estimating the occurrence of undiscovered porphyry copper and polymetallic vein systems has been developed. This model is based on the manner in which magmatic and hydrothermal fluids flow and are trapped in fault systems as far-field stress is released in tectonic strain features above subducting plates (e.g. strike-slip fault systems). The structural traps include preferred locations for stock emplacement and tensional-shear fault meshes within the step-overs that localize porphyry- and vein-style deposits. The application of the model is illustrated for the porphyry copper and polymetallic vein deposits in the Central Slovakian Volcanic Field, Slovakia; the Ma??tra Mountains, Hungary; and the Apuseni Mountains, Romania.
[Treatment of nontumoral portal vein thrombosis in cirrhosis].
Bañares, Rafael; Catalina, María-Vega
2014-07-01
Portal vein thrombosis in cirrhosis is a relatively common complication associated with the presence of an accompanying prothrombotic phenotype of advanced cirrhosis. The consequences of portal vein thrombosis are relevant because it can be associated with impaired hepatic function, might contraindicate hepatic transplantation and could increase morbidity in the surgical procedure. There is controversy concerning the most effective treatment of portal vein thrombosis, which is based on information that is seldom robust and whose primary objective is to achieve a return to vessel patency. Various studies have suggested that starting anticoagulation therapy early is associated with portal vein repatency more frequently than without treatment and has a low rate of complications. There are no proven data on the type of anticoagulant (low-molecular-weight heparins or dicoumarin agents) and the treatment duration. The implementation of TIPS is technically feasible in thrombosis without cavernous transformation and is associated with portal vein recanalization in a significant proportion of cases. Thrombolytic therapy does not appear to present an adequate balance between efficacy and safety; its use is therefore not supported for this indication. The proper definition of treatment for portal vein thrombosis requires properly designed studies to delimit the efficacy and safety of the various alternatives. Copyright © 2014 Elsevier España, S.L. All rights reserved.
How many CT detector rows are necessary to perform adequate three dimensional visualization?
Fischer, Lars; Tetzlaff, Ralf; Schöbinger, Max; Radeleff, Boris; Bruckner, Thomas; Meinzer, H P; Büchler, M W; Schemmer, Peter
2010-06-01
The technical development of computer tomography (CT) imaging has experienced great progress. As consequence, CT data to be used for 3D visualization is not only based on 4 row CTs and 16 row CTs but also on 64 row CTs, respectively. The main goal of this study was to examine whether the increased amount of CT detector rows is correlated with improved quality of the 3D images. All CTs were acquired during routinely performed preoperative evaluation. Overall, there were 12 data sets based on 4 detector row CT, 12 data sets based on 16 detector row CT, and 10 data sets based on 64 detector row CT. Imaging data sets were transferred to the DKFZ Heidelberg using the CHILI teleradiology system. For the analysis all CT scans were examined in a blinded fashion, i.e. both the name of the patient as well as the name of the CT brand were erased. For analysis, the time for segmentation of liver, both portal and hepatic veins as well as the branching depth of portal veins and hepatic veins was recorded automatically. In addition, all results were validated in a blinded fashion based on given quality index. Segmentation of the liver was performed in significantly shorter time (p<0.01, Kruskal-Wallis test) in the 16 row CT (median 479 s) compared to 4 row CT (median 611 s), and 64 row CT (median 670 s), respectively. The branching depth of the portal vein did not differ significantly among the 3 different data sets (p=0.37, Kruskal-Wallis test). However, the branching depth of the hepatic veins was significantly better (p=0.028, Kruskal-Wallis test) in the 4 row CT and 16 row CT compared to 64 row CT. The grading of the quality index was not statistically different for portal veins and hepatic veins (p=0.80, Kruskal-Wallis test). Even though the total quality index was better for the vessel tree based on 64 row CT data sets (mean scale 2.6) compared to 4 CT row data (mean scale 3.25) and 16 row CT data (mean scale 3.0), these differences did not reach statistical difference (p=0.53, Kruskal-Wallis test). Even though 3D visualization is useful in operation planning, the quality of the 3D images appears to be not dependent of the number of CT detector rows. Copyright (c) 2009. Published by Elsevier Ireland Ltd.
Genetic therapy for vein bypass graft disease: current perspectives.
Simosa, Hector F; Conte, Michael S
2004-01-01
Although continued progress in endovascular technology holds promise for less invasive approaches to arterial diseases, surgical bypass grafting remains the mainstay of therapy for patients with advanced coronary and peripheral ischemia. In the United States, nearly 400,000 coronary and 100,000 lower extremity bypass procedures are performed annually. The autogenous vein, particularly the greater saphenous vein, has proven to be a durable and versatile arterial substitute, with secondary patency rates at 5 years of 70 to 80% in the extremity. However, vein graft failure is a common occurrence that incurs significant morbidity and mortality, and, to date, pharmacologic approaches to prolong vein graft patency have produced limited results. Dramatic advances in genetics, coupled with a rapidly expanding knowledge of the molecular basis of vascular diseases, have set the stage for genetic interventions. The attraction of a genetic approach to vein graft failure is based on the notion that the tissue at risk is readily accessible to the clinician prior to the onset of the pathologic process and the premise that genetic reprogramming of cells in the wall of the vein can lead to an improved healing response. Although the pathophysiology of vein graft failure is incompletely understood, numerous relevant molecular targets have been elucidated. Interventions designed to influence cell proliferation, thrombosis, inflammation, and matrix remodeling at the genetic level have been described, and many have been tested in animal models. Both gene delivery and gene blockade strategies have been investigated, with the latter reaching the stage of advanced clinical trials.
NASA Astrophysics Data System (ADS)
Gwon, S.; Edwards, P.; Kim, Y. S.
2015-12-01
Hydrofracturing associated with elevated fluid pressure coupled with changes in stress has been crucial in enhancing the production and recovery of hydrocarbons. Furthermore, it is also an important issue to access the efficiency and stability of long-term CO2 geologic storage reservoirs. Veins are mineral-filled extension fractures developed along the plane of σ1-σ2 and perpendicular to σ3, and the fluid pressure must exceed σ3applied to the plane when the vein opens. Therefore, vein is a well-known natural analogue for fluid migration in a paleo-reservoir. In the Salt Wash Graben of SE Utah, CO2-charged vein systems hosted in the bleached Entrada Formation are well developed and examined to understand the conditions of fluid pressure and stress during the injections of CO2-charged fluid. Based on color and relative cross-cutting relationship in the field, veins are subdivided into two sets; sub-vertical black mineral-rich veins and orthogonal calcite veins that have previously been described as 'grid-lock fractures'. The vein distribution and fluid leakage along through-going fractures in mechanic units allow us to determine the stress regime and driving stress condition through 3D-Mohr circle reconstruction. The results of this statistical analysis for the veins show that the orthogonal veins indicate a 'stress transition' with maximum principal stress direction changing from vertical to NNW-SSE sub-horizontal which coincides with the current regional stress regime. The possible causes of the stress transition can be considered. The process of repeated sealing, reactivation and localization of veins within the bleached zone is a natural indication of a coupled change in pore pressure and stress in the reservoir. Thus, an understanding of the effect of stress changes due to the volumetric injection of CO2 in the subsurface as well as a knowledge of how pre-existing fractures affect fluid flow with respect to elevated pore pressures in layered rocks are important for reservoir characterization and efficient site selection of geologic CO2 storage in the subsurface.
The Genesis of Precious and Base Metal Mineralization at the Miguel Auza Deposit, Zacatecas, Mexico
NASA Astrophysics Data System (ADS)
Findley, A. A.; Olivo, G. R.; Godin, L.
2009-05-01
The Miguel Auza mine located in Zacatecas State, Mexico, is a vein-type polymetallic epithermal deposit hosted in deformed argillite, siltstone and, greywacke of the Cretaceous Caracol Formation. Silver-rich base metal veins (0.2 m to >1.5 m wide) are spatially associated with the NE-striking, steeply SE- dipping (70-80°) Miguel Auza fault over a strike length of 1.6 km and a depth of 460 m. A 2 km2 monzonitic stock located in the proximity of the mineralized zones, has previously been interpreted as the source of the mineralizing fluids. Four distinct structural stages are correlated with hydrothermal mineral deposition: (I) The Pre-ore stage is characterized by normal faulting, fracturing of host rock, and rotation of bedding planes. This stage consists of quartz, illite, chlorite, +/- pyrite alteration of sedimentary wall rocks. (II) The Pyrite-vein stage is associated with reverse-sense reactivation of early normal faults, dilation of bedding planes/fractures, and deposition of generally barren calcite + pyrite veinlets. (III) The Main-ore stage is related to the development of reverse-fault- hosted massive sulphide veins. During this stage three phases of mineral deposition are recorded: early pyrite and arsenopyrite, intermediate chalcopyrite, pyrite, arsenopyrite, and base metals, and late base metals and Ag-bearing minerals. Associated gangue minerals during the main ore stage are quartz, muscovite, calcite and chlorite. (IV) The Post-ore stage involves late NW-SE striking block faulting, brecciation and calcite veining. Later supergene oxidation of veins led to deposition of Fe-oxides and hydroxides, commonly filling fractures or replacing early-formed sulphide assemblages. The various vein types display classic epithermal textures including open space filling, banding, comb quartz and brecciation. The Ag-bearing minerals comprise pyrargyrite [Ag3(Sb,As)S3], argentotennantite [(Cu,Ag)10(Zn,Fe)2(Sn,As)4S13], polybasite-pearceite [(Ag,Cu)16(Sb,As)2S11], and acanthite [AgS2]; associated sulphides include galena, sphalerite, chalcopyrite, arsenopyrite and pyrite. In the main ore zone, base metal sulphides are commonly intergrown with the Ag-bearing sulfosalts. Analyses of galena show no significant silver values indicating that silver grades are exclusively associated with the Ag-bearing sulfosalts and sulphides. The distribution of the Sb/(Sb + As) ratios in the silver sulfosalts indicate that the ore forming fluid(s) was consistently antimony-rich during the Ag-rich ore deposition with no significant variation laterally, vertically, or along strike of the vein systems. However, Ag/(Ag + Cu) values in argentotennantite decrease along-strike from NE to SW and with depth. Compositions of argentotennantite + pyrargyrite + sphalerite indicate a primary depositional temperature around 325-350° C for the late phase of the Main-ore stage. Compositions of sphalerite also show an increasing trend in FeS (mol %) along strike of the deposit from NE to SW. The geometric relationship between the various structures, vein types, and the regional Miguel Auza fault zone suggest episodic reverse-sense reactivation of normal faults. It is argued that the structural evolution of the area, and, in particular, the Main-ore stage, provided transport pathways for metal-rich fluids and controlled the orientations of ore-bearing veins. Variations in mineral chemistry suggest that the rocks in the NE sector interacted with hotter fluids than in the SW part of the deposit.
Worl, Ronald G.; Lewis, Reed S.
2001-01-01
Mineral deposits in the Croesus and Hailey gold belt mineralized areas in Blaine County, south-central Idaho, are preciousand base-metal quartz veins that are part of a family of vein deposits spatially and temporally associated with the Idaho batholith. Historic production from these veins has been mainly gold and silver. Host rocks are older border phase plutons of the Idaho batholith that are characterized by more potassium and less sodium as compared to rocks from the main body of the batholith to the west. Host structures are reverse faults that have moderate to shallow dips to the northeast and high-angle normal faults that also strike northwest. The veins are characterized by several generations of quartz and generally sparse sulfide minerals; gold is associated with late-stage comb quartz. The precious-metal ore bodies are in a series of shoots, each of which is as much as 8 ft in width, 400 ft in breadth, and 1,000 ft in pitch length.
NASA Astrophysics Data System (ADS)
Verlaguet, A.; Brunet, F.; Goffe, B.; Menut, D.; Findling, N.; Poinssot, C.
2011-12-01
In subduction zones, the significant amounts of aqueous fluid released in the course of the successive dehydration reactions occurring during prograde metamorphism are expected to strongly influence the rock rheology, as well as kinetics of metamorphic reactions and mass transfer efficiency. Mineralized veins, ubiquitous in metamorphic rocks, can be seen as preserved witnesses of fluid and mass redistribution that partly accommodate the rock deformation (lateral segregation). However, the driving forces and mechanisms of mass transfer towards fluid-filled open spaces remain somewhat unclear. The aim of this study is to investigate the modalities of mass transfer during local fluid-rock interactions, and their links with fluid production and rock deformation. This study focuses on karstic pockets (metre scale) of Triassic metabauxites embedded in thick carbonate units, that have been isolated from large-scale fluid flow during HP-LT Alpine metamorphism (W. Vanoise, French Alps). These rocks display several generations of metamorphic veins containing various Al-bearing minerals, which give particular insights into mass transfer processes. It is proposed that the internally-derived fluid (~13 vol% produced by successive dehydration reactions) has promoted the opening of fluid-filled open spaces (euhedral habits of vein minerals) and served as medium for diffusive mass transfer from rock to vein. Based on mineralogical and textural features, two vein types can be distinguished: (1) some veins are filled with newly formed products of either prograde (chloritoid) or retrograde (chlorite) metamorphic reactions; in this case, fluid-filled open spaces seem to offer energetically favourable nucleation/growth sites; (2) the second vein type is filled with cookeite (Li-Al-rich chlorite) or pyrophyllite, that were present in the host rock prior to the vein formation. In this closed chemical system, mass transfer from rock to vein was achieved through the fluid, in a dissolution-transport-precipitation process, possibly stress-assisted. Cookeite is highly concentrated (40-70 vol%) in regularly spaced veins. Laser Induced Breakdown Spectroscopy profiles show that cookeite is evenly distributed in the rock matrix comprised between two veins. The absence of diffusion profiles suggests that the characteristic diffusion length for Li, Al and Si is greater than or equal to the distance separating two cookeite veins (3-6 cm). This is in agreement with characteristic diffusion lengths calculated from both grain boundary and pore fluid diffusion coefficients, for the estimated duration of the peak of metamorphism. Phyllosilicates have very different morphologies in the rock matrix (fibers) compared to veins (euhedral crystals): fluid-mineral interfacial energy may be maximal in the small matrix pores, which can maintain higher cookeite solubility than in fluid-filled open spaces. Therefore, as soon as veins open, chemical potential gradients may develop and drive cookeite transfer from rock matrix to veins.
NASA Astrophysics Data System (ADS)
Rottier, Bertrand; Kouzmanov, Kalin; Casanova, Vincent; Bouvier, Anne-Sophie; Baumgartner, Lukas P.; Wälle, Markus; Fontboté, Lluís
2018-01-01
Cerro de Pasco (Peru) is known for its large epithermal polymetallic (Zn-Pb-Ag-Cu-Bi) mineralization emplaced at shallow level, a few hundred meters below the paleo-surface, at the border of a large diatreme-dome complex. Porphyry-style veins crosscutting hornfels and magmatic rock clasts are found in the diatreme breccia and in quartz-monzonite porphyry dikes. Such mineralized veins in clasts allow investigation of high-temperature porphyry-style mineralization developed in the deep portions of magmatic-hydrothermal systems. Quartz in porphyry-style veins contains silicate melt inclusions as well as fluid and solid mineral inclusions. Two types of high-temperature (> 600 °C) quartz-molybdenite-(chalcopyrite)-(pyrite) veins are found in the clasts. Early, thin (1-2 mm), and sinuous HT1 veins are crosscut by slightly thicker (up to 2 cm) and more regular HT2 veins. The HT1 vein quartz hosts CO2- and sulfur-rich high-density vapor inclusions. Two subtypes of the HT1 veins have been defined, based on the nature of mineral inclusions hosted in quartz: (i) HT1bt veins with inclusions of K-feldspar, biotite, rutile, and minor titanite and (ii) HT1px veins with inclusions of actinolite, augite, titanite, apatite, and minor rutile. Using an emplacement depth of the veins of between 2 and 3 km (500 to 800 bar), derived from the diatreme breccia architecture and the supposed erosion preceding the diatreme formation, multiple mineral thermobarometers are applied. The data indicate that HT1 veins were formed at temperatures > 700 °C. HT2 veins host assemblages of polyphase brine inclusions, generally coexisting with low-density vapor-rich inclusions, trapped at temperatures around 600 °C. Rhyolitic silicate melt inclusions found in both HT1 and HT2 veins represent melt droplets transported by the ascending hydrothermal fluids. LA-ICP-MS analyses reveal a chemical evolution coherent with the crystallization of an evolved rhyolitic melt. Quartz from both HT1 and HT2 veins also contains secondary, low-temperature ( 300 °C) brine and aqueous fluid inclusions that record the cooling of the system. Both vein types are locally crosscut and/or reopened by a pre-diatreme polymetallic event consisting of pyrite, sphalerite with "chalcopyrite disease," galena, chalcopyrite, tetrahedrite-tennantite, and minor quartz. LA-ICP-MS analyses of mineral and high-temperature fluid inclusions hosted in HT1 and HT2 veins and in situ secondary-ion mass spectrometry oxygen isotope analyses of vein quartz indicate a magmatic signature for the mineralizing fluids with no major meteoric water input and allow reconstruction of the source and chemical evolution of fluids that formed these porphyry-style veins as snapshots of the early and deep mineralizations at Cerro de Pasco. This detailed study of the porphyry-type mineralization hosted in clasts offers a unique opportunity to reconstruct the late magmatic and early hydrothermal evolutions of porphyry mineralization underlying the world-class Cerro de Pasco epithermal polymetallic (Zn-Pb-Ag-Cu-Bi) deposit.
Berardinelli-Seip congenital lipodystrophy in two siblings
Rao, T. S. Mohana; Chennamsetty, Kavya
2014-01-01
Berardinelli-Seip congenital lipodystrophy (BSCL) is a very rare autosomal recessive disorder characterized by various dermatological and systemic manifestations such as lipoatrophy, hypertriglyceridemia, hepatomegaly, acanthosis nigricans, and acromegaloid features. BSCL type 2 is more common and severe, with onset in the neonatal period or in early infancy. The locus for BSCL2 has been identified on chromosome 11q13. Early recognition and differentiation from other congenital generalized lipodystrophies help in the initiation of appropriate preventive and therapeutic measures such as lifestyle modification and pharmacotherapy that helps postpone the onset of metabolic syndrome. We report BSCL type 2 in two siblings with several cutaneous manifestations like acanthosis nigricans, hypertrichosis, prominent subcutaneous veins, and increased lanugo hair. PMID:25506557
Physical examination: how to examine the arm with arteriovenous fistula.
Sousa, Clemente Neves; Apóstolo, João Luís; Figueiredo, Maria Henriqueta; Martins, Maria Manuela; Dias, Vanessa Filipa
2013-04-01
Physical examination has demonstrated its effectiveness in identifying complications of arteriovenous fistula (AVF). It should be initiated at the stage prior to the construction of the AVF and continue in its accomplishment, maturation, and subsequent use in the treatment of hemodialysis. Nurses should incorporate the physical examination in their practices, in order to preserve the vascular net of patients and assist in the recognition of complications of AVF. It is intended to describe aspects of the physical examination that enable the identification of the AVF complications including: infection, accessory veins, venous stenosis, steal syndrome, high-output cardiac failure, and venous hypertension. © 2012 The Authors. Hemodialysis International © 2012 International Society for Hemodialysis.
Acoustic heart. Interpretation of Phonocardiograms by computer
NASA Astrophysics Data System (ADS)
Granados, J.; Tavera, F.; Velázquez, J. M.; López, G.; Hernández, R. T.; Morales, A.
2015-01-01
In the field of Cardiology have been identified several heart pathologies associated with problems in valves and narrowing in veins. Each case is associated with a specific sound emitted by the heart, detected in cardiac auscultation. On the Phonocardiogram, sound is visualized as a peak in the wave. In the Optics Laboratory of the Universidad Autonoma Metropolitana - Azcapotzalco, we have developed a simulation of the Phonocardiograms of heart sounds associated with the main pathologies and a computer program of recognition of images that allows you to quickly identify the respective diseases. This is a novel way to analyze Phonocardiograms and the foundation for building a portable non-invasive cardiac diagnostic computerized analyzer system.
NASA Astrophysics Data System (ADS)
Márquez-Zavalía, M. Florencia; Heinrich, Christoph A.
2016-10-01
Alto de la Blenda is a ˜6.6-Ma intermediate-sulphidation epithermal vein system in the Farallón Negro Volcanic Complex, which also hosts the 7.1-Ma porphyry-Cu-Au deposit of Bajo de la Alumbrera. The epithermal vein system is characterised by a large extent and continuity (2 km × 400 m open to depth × 6 m maximum width) and an average gold grade of ˜8 g/t. The vein is best developed within an intrusion of a fine-grained equigranular monzonite, interpreted as the central conduit of a stratovolcano whose extrusive activity ended prior to porphyry-Cu-Au emplacement at Bajo de la Alumbrera, which is in turn cut by minor epithermal veins. The Alto de la Blenda vein consists predominantly of variably Mn-rich carbonates and quartz, with a few percent of pyrite, sphalerite, galena and other sulphide and sulphosalt minerals. Four phases of vein opening, hydrothermal mineralisation and repeated brecciation can be correlated between different vein segments. Stages 2 and 3 contain the greatest fraction of sulphide and gold. They are separated by the emplacement of a polymictic breccia containing clasts of quartz feldspar porphyry as well as basement rocks. Fluid inclusions in quartz related to stages 2 to 4 are liquid rich with 2-4 wt% NaCl(eq). They homogenise between 160 and 300 °C, with very consistent values within each assemblage. Vapour inclusions are practically absent in the epithermal vein. Quartz fragments in the polymictic breccia contain inclusions of intermediate to vapour-like density and similar low salinity (˜3 wt% NaCl(eq)), besides rare brine inclusions containing halite. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) analyses of epithermal inclusions indicate high concentrations of K, Fe, As, Sb, Cs, and Pb that significantly vary within and through subsequent vein stages. Careful consideration of detection limits for individual inclusions shows high gold concentrations of ˜0.5 to 3 ppm dissolved in the ore fluid, which contains variably high sulphur concentrations in excess over Fe and other chalcophile metals. Compositional variations are interpreted to reflect cooling and contraction of lower-density magmatic fluids at depth, like those preserved in porphyry clasts that were mechanically transported up by the polymictic breccia. Ore mineral precipitation from the magmatic fluid occurred by further cooling and possibly minor mixing with surface-derived water, leading to sulphide saturation, de-sulphidation of the magmatic fluid and consequent gold precipitation. The absence of flash boiling and/or reduction by carbonaceous host rocks has led to relatively modest but constant gold grades in the carbonate-base metal-gold veins of Alto de la Blenda.
Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas
2015-01-01
Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach for rats and that it provides results for test compound concentrations that are equivalent to those obtained from traditional whole blood sampling. The data also suggest that for some compounds, the concentration-time profile that is obtained for a test compound based on sampling from a rat tail vein may be different from that obtained from rat JVC sampling. In some cases, this shift in the concentration-time profile will result in different PK parameters for the test compound. Based on these observations, it is recommended that a consistent blood sampling method should be used for serial microsampling in discovery rat PK studies when testing multiple new chemical entities. If the rat tail vein sampling method is selected for PK screening, then conducting a bridging study on the lead compound is recommended to confirm that the rat PK obtained from JVC sampling is comparable to the tail-vein sampling. Copyright © 2015 Elsevier Inc. All rights reserved.
Angioarchitecture of the bovine spermatic cord.
Polguj, Michał; Jȩdrzejewski, Kazimierz S; Topol, Mirosław
2011-04-01
We described the topography and morphometry of the testicular artery, pampiniform plexus veins, and indirect connections between them in the spermatic cord of the bull. Sixty microcorrosive casts of bovine spermatic cords were analyzed macroscopically, by stereomicroscopy, and by scanning electron microscopy. The average size of the testicles was 94.6 × 49.7 × 54.7 mm. The testicular artery formed a superiorly pointed cone-like structure with its base fixed to the proximal part of the gonad. The artery gave off one or two branches to the head of epididymis and to the deferens duct. The pampiniform plexus originated from intra-tunical veins. Veins of the pampiniform plexus were of smaller diameter but larger number than intra-tunical ones. The density of the veins of the pampiniform plexus was 9.37 ± 1.07 mm(-2) . The testicular vein began 90-121 mm above the superior pole of the testis. In 2.9% of specimens, the testicular vein was doubled. Numerous anastomoses among veins of pampiniform plexus were observed. Additionally, indirect anastomoses between the testicular artery and pampiniform plexus veins formed by the capillary network of the vasa vasorum of the testicular artery were visualized by scanning electron microscopy. In all cases, narrowings in the casts of the precapillary vessel were observed. We also documented the vasa vasorum of the testicular artery in bulls. The density of these vessels was 22.87 ± 11.48 mm(-2) . The indirect arteriovenous connections together with the presence of circular constrictions of the lumen in precapillary vessels may play a role in testicular blood flow regulation. Copyright © 2011 Wiley-Liss, Inc.
Corneal topography measurements for biometric applications
NASA Astrophysics Data System (ADS)
Lewis, Nathan D.
The term biometrics is used to describe the process of analyzing biological and behavioral traits that are unique to an individual in order to confirm or determine his or her identity. Many biometric modalities are currently being researched and implemented including, fingerprints, hand and facial geometry, iris recognition, vein structure recognition, gait, voice recognition, etc... This project explores the possibility of using corneal topography measurements as a trait for biometric identification. Two new corneal topographers were developed for this study. The first was designed to function as an operator-free device that will allow a user to approach the device and have his or her corneal topography measured. Human subject topography data were collected with this device and compared to measurements made with the commercially available Keratron Piccolo topographer (Optikon, Rome, Italy). A third topographer that departs from the standard Placido disk technology allows for arbitrary pattern illumination through the use of LCD monitors. This topographer was built and tested to be used in future research studies. Topography data was collected from 59 subjects and modeled using Zernike polynomials, which provide for a simple method of compressing topography data and comparing one topographical measurement with a database for biometric identification. The data were analyzed to determine the biometric error rates associated with corneal topography measurements. Reasonably accurate results, between three to eight percent simultaneous false match and false non-match rates, were achieved.
Bove, Dana J.; Kurtz, Jeffrey P.; Wright, Winfield G.
2002-01-01
The Palmetto Gulch area is affected by low pH and metal-bearing drainage from abandoned mines, and perhaps, from natural weathering around vein zones. To investigate these anthropogenic and potential natural sources of acidity and metals, we mapped the geology, veins, and hydrothermally altered areas; conducted mine dump leachate studies; and collected reconnaissance water quality data. Several small abandoned mines are present in the Palmetto Gulch area that produced small amounts of relatively high-grade silver ore from fault-controlled polymetallic vein deposits. These veins are hosted in lavas, breccias, and related volcaniclastic sediments that ponded within the 28 Ma San Juan-Uncompahgre caldera complex. These rock units generally have conformable contacts and have shallow dips to the northwest. Lava flows of pyroxene andesite, which host the Roy-Pray mine, are massive near their base and typically grade upward into tightly jointed rock with 2-15 cm joint spacing. In general, most hydrothermally altered rock within the Palmetto Gulch area is restricted to envelopes surrounding the mineralized veins and faults. Composite zones of vein-related alteration vary from about 50 to 80 m wide along the high ridgelines and narrow to less than 10 to 15 m beneath an elevation of about 5,462 m. Where unaffected by surficial oxidation, these altered zones contain as much as 7 to 10 volume percent finely-disseminated pyrite. The majority of rocks in the area were affected by regional and vein-related propylitic alteration. These greenish-colored rocks have alteration products consisting of chlorite, illite, and calcite; and feldspars are typically weakly altered. Most of these rocks have detectable amounts of calcite, while as much as 11 percent by weight was detected in samples collected during this study. The Palmetto Gulch area is affected by low pH and metal-bearing drainage from abandoned mines, and perhaps, from natural weathering around vein zones. To investigate these anthropogenic and potential natural sources of acidity and metals, we mapped the geology, veins, and hydrothermally altered areas; conducted mine dump leachate studies; and collected reconnaissance water quality data. Several small abandoned mines are present in the Palmetto Gulch area that produced small amounts of relatively high-grade silver ore from fault-controlled polymetallic vein deposits. These veins are hosted in lavas, breccias, and related volcaniclastic sediments that ponded within the 28 Ma San Juan-Uncompahgre caldera complex. These rock units generally have conformable contacts and have shallow dips to the northwest. Lava flows of pyroxene andesite, which host the Roy-Pray mine, are massive near their base and typically grade upward into tightly jointed rock with 2-15 cm joint spacing. In general, most hydrothermally altered rock within the Palmetto Gulch area is restricted to envelopes surrounding the mineralized veins and faults. Composite zones of vein-related alteration vary from about 50 to 80 m wide along the high ridgelines and narrow to less than 10 to 15 m beneath an elevation of about 5,462 m. Where unaffected by surficial oxidation, these altered zones contain as much as 7 to 10 volume percent finely-disseminated pyrite. The majority of rocks in the area were affected by regional and vein-related propylitic alteration. These greenish-colored rocks have alteration products consisting of chlorite, illite, and calcite; and feldspars are typically weakly altered. Most of these rocks have detectable amounts of calcite, while as much as 11 percent by weight was detected in samples collected during this study.
[Botulism. Summary based on six cases].
Adorján, T; Farkas, M; Boros, L; Czeglédi, Z
1998-10-18
Botulism is a rare neuroparalytic disease caused by neurotoxins of Clostridium species. In Hungary it most commonly occurs as a foodborne illness with ocular and bulbar paralysis, muscle weakness and gastrointestinal symptoms. Six cases of botulism were observed by the authors, first in 1993 five members of a family, then in 1997 a patient with sporadic illness. The diagnosis was confirmed by toxin tests in addition to the symptoms and food history. Recognition of the epidemiologic associations proved very useful in the confirmation of outbreak-related cases. The illness was moderately serious at three patients and mild at two patients. One of the patients had a cirrhosis of the liver, and her status became critical because of the repeated bleeding from oesophagus varicose vein. The patient with sporadic illness had a serious gastric dilatation and palsy of bowels causing paralytic ileus at the start of the illness. The symptoms regressed slowly, roughly in three weeks, at all patients. Death did not happened. After the case reports the authors review the disease-microorganism, toxin, clinical entities, incidence, symptoms, diagnosis, differential-diagnosis, and finally the treatment.
NASA Astrophysics Data System (ADS)
Verlaguet, Anne; Brunet, Fabrice; Goffé, Bruno; Menut, Denis; Findling, Nathaniel; Poinssot, Christophe
2013-04-01
In subduction zones, the significant amounts of aqueous fluid released in the course of the successive dehydration reactions occurring during prograde metamorphism are expected to strongly influence the rock rheology, as well as kinetics of metamorphic reactions and mass transfer efficiency. Mineralized veins, ubiquitous in metamorphic rocks, can be seen as preserved witnesses of fluid and mass redistribution that partly accommodate the rock deformation (lateral segregation). However, the driving forces and mechanisms of mass transfer towards fluid-filled open spaces remain somewhat unclear. The aim of this study is to investigate the vein-forming processes and the modalities of mass transfer during local fluid-rock interactions, and their links with fluid production and rock deformation, with new insights from Laser Induced Breakdown Spectroscopy (LIBS) profiles. This study focuses on karstic pockets (metre scale) of Triassic metabauxites embedded in thick carbonate units, that have been isolated from large-scale fluid flow during HP-LT Alpine metamorphism (W. Vanoise, French Alps). These rocks display several generations of metamorphic veins containing various Al-bearing minerals, which give particular insights into mass transfer processes. It is proposed that the internally-derived fluid (~13 vol% produced by successive dehydration reactions) has promoted the opening of fluid-filled open spaces (euhedral habits of vein minerals) and served as medium for diffusive mass transfer from rock to vein. Based on mineralogical and textural features, two vein types can be distinguished: (1) some veins are filled with newly formed products of either prograde (chloritoid) or retrograde (chlorite) metamorphic reactions; in this case, fluid-filled open spaces seem to offer energetically favourable nucleation/growth sites; (2) the second vein type is filled with cookeite (Li-Al-rich chlorite) or pyrophyllite, that were present in the host rock prior to the vein formation. In this closed chemical system, mass transfer from rock to vein was achieved through the fluid, in a dissolution-transport-precipitation process, possibly stress-assisted. To investigate the modalities of mass transfer towards this second vein type, LIBS profiles were performed in the rock matrix, taking Li concentration as a proxy for cookeite distribution. Cookeite is highly concentrated (40-70 vol%) in regularly spaced veins, and the LIBS profiles show that cookeite is evenly distributed in the rock matrix comprised between two veins. The absence of diffusion profiles suggests that the characteristic diffusion length for Li, Al and Si is greater than or equal to the distance separating two cookeite veins (3-6 cm). This is in agreement with characteristic diffusion lengths calculated from both grain boundary and pore fluid diffusion coefficients, for the estimated duration of the peak of metamorphism. Concerning mass transfer driving forces, phyllosilicates have very different morphologies in the rock matrix (fibers) compared to veins (euhedral crystals): fluid-mineral interfacial energy may be maximal in the small matrix pores, which can maintain higher cookeite solubility than in fluid-filled open spaces. Therefore, as soon as veins open, chemical potential gradients may develop and drive cookeite transfer from rock matrix to veins.
Kay, Annika Bickford; Majercik, Sarah; Sorensen, Jeffrey; Woller, Scott C; Stevens, Scott M; White, Thomas W; Morris, David S; Baldwin, Margaret; Bledsoe, Joseph R
2018-04-23
Venous thromboembolism is a cause of morbidity and mortality in trauma patients. Chemoprophylaxis with low-molecular-weight heparin at a standardized dose is recommended. Conventional chemoprophylaxis may be inadequate. We hypothesized that a weight-adjusted enoxaparin prophylaxis regimen would reduce the frequency of venous thromboembolism in hospitalized trauma patients and at 90-day follow-up. This prospective, randomized pilot study enrolled adult patients admitted to a level 1 trauma center between July 2013 and January 2015. Subjects were randomized to receive either standard (30 mg subcutaneously every 12 hours) or weight-based (0.5mg/kg subcutaneously every 12 hours) enoxaparin. Surveillance duplex ultrasound for lower extremity deep vein thrombosis was performed on hospital days 1, 3, and 7, and weekly thereafter. The primary outcome was deep vein thrombosis during hospitalization. Secondary outcomes included venous thromboembolism at 90 days and significant bleeding events. Two hundred thirty-four (124 standard, 110 weight-based) subjects were enrolled. There was no difference between standard and weight-based regarding age, body mass index, percentage female gender, injury severity score, or percentage that had surgery. There was a trend toward less in-hospital deep vein thrombosis in weight-based (12 [9.7%] standard vs 4 [3.6%] weight-based, P = .075). At 90 days, there was no difference in venous thromboembolism (12 [9.7%] standard vs 6 [5.5%] weight-based, P =.34). There was 1 bleeding event, which occurred in a standard subject. Weight-based enoxaparin dosing for venous thromboembolism chemoprophylaxis in trauma patients may provide better protection against venous thromboembolism than standard. A definitive study is necessary to determine whether weight-based dosing is superior to standard. Copyright © 2018 Elsevier Inc. All rights reserved.
Implementing a research utilization plan for prevention of deep vein thrombosis.
Van Wicklin, Sharon A; Ward, Karen S; Cantrell, Shirley W
2006-06-01
Ensuring use of best practices is crucially important in today's health care system. Nurses can identify research results that offer promising new treatment options for their patients and should have a plan for implementing research findings. The perioperative education coordinator at one facility identified the occurrence of deep vein thrombosis as a significant problem. She conducted a literature review, created an education program for nurses, and implemented an evidence-based practice change. This article describes the steps in this process. Now, patients at the facility consistently are assessed for deep vein thrombosis and receive appropriate preventive treatment.
First Observations of Boron on Mars and Implications for Gale Crater Geochemistry
NASA Astrophysics Data System (ADS)
Gasda, P. J.; Haldeman, E. B.; Wiens, R. C.; Rapin, W.; Frydenvang, J.; Maurice, S.; Clegg, S. M.; Delapp, D.; Sanford, V.; McInroy, R.
2016-12-01
Borates are potentially important precursor materials for the origin of life on Earth. It has been shown that borates are required to stabilize ribose, a component of RNA, when produced by the formose reaction, a prebiotically plausible mechanism to produce ribose from formaldehyde. Evaporites, including borates, also shed light on the history of aqueous activity on Mars. The ChemCam instrument onboard the NASA Curiosity rover provides quantitative elemental compositions of targets in Gale Crater, Mars, using laser-induced breakdown spectroscopy (LIBS). Laboratory observations of Fe-free targets indicate that a LIBS emission line is visible with as little as 10 ppm B. We have observed B lines in 23 calcium sulfate veins in Gale Crater: 3 in Yellowknife Bay and 20 in the Murray lacustrine mudstone and the Stimson eolian sandstone units since sol 727, as Curiosity arrived at the base of Mt. Sharp, a 5 km sedimentary mound in the center of Gale Crater. To calibrate these observations, samples composed of borates diluted with Hawaiian basalt have been analyzed using the LANL ChemCam engineering model. Preliminary results show that the Gale Crater veins have between 10-100 ppm B. One possible explanation for borates in veins is that Gale Lake evaporated, depositing evaporites, including borates. Later, Gale Crater was partially buried and its lacustrine and overlying eolian units were lithified and fractured. Water flowed through the evaporite-rich layers, partially dissolving them. Fluid moved through the fractures, re-precipitating the borates and sulfates as veins. ChemCam cannot directly determine mineralogy, but B is likely present as borax as the dominate borate phase in these veins, based on previous estimates of vein fluid temperature. Borates forming in this environment tend to precipitate from mildly alkaline fluids. The fluid temperature and pH implies these veins were potentially habitable environments.
Tseng, Yujen; Ma, Lili; Luo, Tiancheng; Zeng, Xiaoqing; Li, Feng; Li, Na; Wei, Yichao; Chen, Shiyao
2018-04-27
Gastroesophageal variceal hemorrhage is a common complication of portal hypertension. Endoscopic therapy is currently recommended for preventing gastroesophageal variceal rebleed. However, the rate of variceal rebleed and its associated mortality remain concerning. This study is aimed at differentiating patient response to endoscopic therapy based on endoscopic ultrasound (EUS) findings. One-hundred seventy patients previously treated with repeat endoscopic therapy for secondary prophylaxis were enrolled and classified into two groups based on treatment response. Prior to consolidation therapy, all patients received an EUS examination to observe for extraluminal phenomena. All available follow-up endoscopic examination records were retrieved to validate study results. Of the 170 subjects, 106 were poor responders, while 64 were good responders. The presence of para-gastric, gastric perforating, and esophageal perforating veins was associated with poor patient response (p<0.001). The odds ratio for para-gastric veins was 5.374. Follow-up endoscopic findings for poor responders with incomplete variceal obliteration was closely correlated with the presence of para-gastric veins (p=0.002). The presence of para-gastric veins is a characteristic of poor response to endoscopic therapy for treating gastroesophageal varices. Early identification of this subgroup necessitates a change in course of treatment to improve overall patient outcome.
NASA Astrophysics Data System (ADS)
Verlaguet, Anne; Brunet, Fabrice; Goffé, Bruno; Menut, Denis; Findling, Nathaniel; Poinssot, Christophe
2015-04-01
In subduction zones, the significant amounts of aqueous fluid released in the course of the successive dehydration reactions occurring during prograde metamorphism are expected to strongly influence the rock rheology, as well as kinetics of metamorphic reactions and mass transfer efficiency. Mineralized veins, ubiquitous in metamorphic rocks, can be seen as preserved witnesses of fluid and mass redistribution that partly accommodate the rock deformation (lateral segregation). However, the driving forces and mechanisms of mass transfer towards fluid-filled open spaces remain somewhat unclear. The aim of this study is to investigate the vein-forming processes and the modalities of mass transfer during local fluid-rock interactions, and their links with fluid production and rock deformation, with new insights from Laser Induced Breakdown Spectroscopy (LIBS) profiles. This study focuses on karstic pockets (metre scale) of Triassic metabauxites embedded in thick carbonate units, that have been isolated from large-scale fluid flow during HP-LT Alpine metamorphism (W. Vanoise, French Alps). These rocks display several generations of metamorphic veins containing various Al-bearing minerals, which give particular insights into mass transfer processes. It is proposed that the internally-derived fluid (~13 vol% produced by successive dehydration reactions) has promoted the opening of fluid-filled open spaces (euhedral habits of vein minerals) and served as medium for diffusive mass transfer from rock to vein. Based on mineralogical and textural features, two vein types can be distinguished: (1) some veins are filled with newly formed products of either prograde (chloritoid) or retrograde (chlorite) metamorphic reactions; in this case, fluid-filled open spaces seem to offer energetically favourable nucleation/growth sites; (2) the second vein type is filled with cookeite (Li-Al-rich chlorite) or pyrophyllite, which were present in the host-rock prior to the vein formation. In this closed chemical system, mass transfer from rock to vein was achieved through the fluid, in a dissolution-transport-precipitation process. To investigate the modalities of mass transfer towards this second vein type, LIBS profiles were performed in the host-rock, taking Li concentration as a proxy for cookeite distribution. Cookeite is highly concentrated (45-65 vol%) in regularly spaced veins, and the LIBS profiles show that cookeite is evenly distributed in the host-rock comprised between two veins. The absence of diffusion profiles suggests that the characteristic diffusion distance for Li, Al and Si is greater than or equal to the distance separating two cookeite veins (2-4 cm). This is in agreement with characteristic diffusion lengths calculated from both grain boundary and pore fluid diffusion coefficients, for the estimated duration of the peak of metamorphism. Which driving forces are responsible for cookeite selective transfer towards veins? Chemical potential gradients between host-rock pores and veins may have developed in response to either (1) a stress difference: thermochemical calculations show that pressure-solution processes may affect preferentially cookeite and pyrophyllite; (2) a difference in interfacial energy, phyllosilicates showing very different morphologies in host-rocks (fibers) compared to veins (euhedral crystals); fluid-mineral interfacial energy may be maximal in the small host-rock pores, which can maintain higher cookeite solubility than large fluid-filled open spaces (i.e., veins).
NASA Astrophysics Data System (ADS)
Aihara, Y.; Kiyokawa, S.; Ito, T.; Ikehara, M.; Yamaguchi, K. E.; Horie, K.; Sakamoto, R.; Miki, T.
2013-12-01
Stratigraphic transition of black chert to iron-rich sedimentary rocks above volcanic sequences with hydrothermal systems is common and characteristic feature of Archean greenstone belts. The 3.2 Ga Dixon Island Formation, exposed along the northern coast of Dixon Island located in the coastal Pilbara terrane, Western Australia, is one of such units and the focus of our study. We introduce field occurrence and lithology of the Dixon Island Formation that preserves features of paleohydrohermal environment in the Mesoarchean ocean. The Dixon Island Formation is composed of the following three members (in ascending order): Komatiite-Rhyolite Tuff, Black Chert, and Varicolored Chert members (Kiyokawa and Taira, 1998). Here we focus on the Komatiite-Rholite Tuff member. It preserves two cycles of highly altered komatiite lavas and well-stratified rhyolite tuff. Komatiite lavas include dendritic crystals of chrome spinel and ghosts of spinifex, euhedral and sheet-like olivines and pyroxenes. These rocks are now composed of granular microcrystalline quartz with chromian muscovite, chrome spinel and chrorite that formed by intense silicification. Its upper part contains hydrothermal veining and alteration (i.e., many vein swarms composed of veins of quartz and organic carbon-rich black chert). Most black chert veins intrude vertically into overlying layers, and contain barite, pyrite, monazite and clay minerals which were least affected by silicificatio. Based on the cross-cutting relationship seen in the outcrops, we recognized two generations of black chert veins (type 1 and type 2 veins; Kiyokawa et al., 2006). Type 1 veins are mainly composed of carbonaceous peloids in a microcrystalline quartz matrix. Euhedral and xenocrystic tourmaline are found only in Type1 veins. Type 2 veins are organic carbon-poor and contain fragments of black chert and siliceous volcanic breccia (Kiyokawa et al., 2006). Intense silicification of komatiitic volcaniclastics and lava, enriched in Si and K and depleted in Mg, occurred earlier than the formation of black chert veins and probably during sedimentation of the overlying Black Chert member. Petrographycally, tourmaline in Type1 veins formed by hydrothermal processes and can be used to infer physicochemical conditions of the hydrothermal activity. Fragmentation of black chert and volcanic rocks within Type 2 veins was probably due to high pressure caused by hydrothermal activity.
In vivo study of the surgical anatomy of the axilla.
Khan, A; Chakravorty, A; Gui, G P H
2012-06-01
Classical anatomical descriptions fail to describe variants often observed in the axilla as they are based on studies that looked at individual structures in isolation or textbooks of cadaveric dissections. The presence of variant anatomy heightens the risk of iatrogenic injury. The aim of this study was to document the nature and frequency of these anatomical variations based on in vivo peroperative surgical observations. Detailed anatomical relationships were documented prospectively during consecutive axillary dissections. Relationships between the thoracodorsal pedicle, course of the lateral thoracic vein, presence of latissimus dorsi muscle slips, variations in axillary and angular vein anatomy, and origins and branching of the intercostobrachial nerve were recorded. Among a total of 73 axillary dissections, 43 (59 per cent) revealed at least one anatomical variant. Most notable variants included aberrant courses of the thoracodorsal nerve in ten patients (14 per cent)--three variants; lateral thoracic vein in 12 patients (16 per cent)--four variants; bifid axillary veins in ten patients (14 per cent); latissimus dorsi muscle slips in four patients (5 per cent); and variants in intercostobrachial nerve origins and branching in 26 patients (36 per cent). The angular vein, a subscapular vein tributary, was found to be a constant axillary structure. Variations in axillary anatomical structures are common. Poor understanding of these variants can affect the adequacy of oncological clearance, lead to vascular injury, compromise planned microvascular procedures and result in chronic pain or numbness from nerve injury. Surgeons should be aware of the common anatomical variants to facilitate efficient and safe axillary surgery. Copyright © 2012 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Miyahara, Masaaki; Ohtani, Eiji; Yamaguchi, Akira
2017-11-01
An impact event recorded in the Northwest Africa (NWA) 8275 LL7 ordinary chondrite was investigated based on high-pressure mineralogy of pervasive shock-melt veins present in the rock. NWA 8275 consists of olivine, low-Ca pyroxene, plagioclase (albite-oligoclase composition), and minor high-Ca pyroxene, K-feldspar, phosphate minerals, metallic Fe-Ni and iron sulfide. Plagioclase and K-feldspar grains near the shock-melt veins have become amorphous, although no high-pressure polymorphs of olivine and pyroxene were identified in or adjacent the shock-melt veins. Raman spectroscopy and focused ion beam (FIB)-assisted transmission electron microscopy (TEM) observations reveal that plagioclase entrained around the center portion of the shock-melt veins has dissociated into a jadeite + coesite assemblage. Alternately stacked jadeite and coesite crystals occur in the original plagioclase. On approaching the host rock/shock-melt vein, only jadeite is present. Based on the high-pressure polymorph assemblage, the shock pressure and temperature conditions recorded in the shock-melt veins are ∼3-12 GPa and ∼1973-2373 K, respectively. Following a Rankine-Hugoniot relationship, the impact velocity was at least ∼0.45-1.54 km/s. The duration of high-pressure and high-temperature (HPHT) conditions required for the albite dissociation reaction is estimated a maximum of ∼4-5 s using the phase transition rate of albite, implying that a body of up to ∼9-12 km across collided with the parent body of NWA 8275. The coexistence of jadeite and coesite, the latter of which rarely accompanies jadeite in shocked ordinary chondrites, as a dissociation product of albite requires relatively long duration HPHT conditions. Thus, the impact event recorded in NWA 8275 was likely caused by a larger-than-typical projectile.
Noda, Y; Goshima, S; Nagata, S; Miyoshi, T; Kawada, H; Kawai, N; Tanahashi, Y; Matsuo, M
2018-06-01
To compare right adrenal vein (RAV) visualisation and contrast enhancement degree on adrenal venous phase images reconstructed using adaptive statistical iterative reconstruction (ASiR) and model-based iterative reconstruction (MBIR) techniques. This prospective study was approved by the institutional review board, and written informed consent was waived. Fifty-seven consecutive patients who underwent adrenal venous phase imaging were enrolled. The same raw data were reconstructed using ASiR 40% and MBIR. The expert and beginner independently reviewed computed tomography (CT) images. RAV visualisation rates, background noise, and CT attenuation of the RAV, right adrenal gland, inferior vena cava (IVC), hepatic vein, and bilateral renal veins were compared between the two reconstruction techniques. RAV visualisation rates were higher with MBIR than with ASiR (95% versus 88%, p=0.13 in expert and 93% versus 75%, p=0.002 in beginner, respectively). RAV visualisation confidence ratings with MBIR were significantly greater than with ASiR (p<0.0001, both in the beginner and the expert). The mean background noise was significantly lower with MBIR than with ASiR (p<0.0001). Mean CT attenuation values of the RAV, right adrenal gland, IVC, and hepatic vein were comparable between the two techniques (p=0.12-0.91). Mean CT attenuation values of the bilateral renal veins were significantly higher with MBIR than with ASiR (p=0.0013 and 0.02). Reconstruction of adrenal venous phase images using MBIR significantly reduces background noise, leading to an improvement in the RAV visualisation compared with ASiR. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Stochastic inversion of cross-borehole radar data from metalliferous vein detection
NASA Astrophysics Data System (ADS)
Zeng, Zhaofa; Huai, Nan; Li, Jing; Zhao, Xueyu; Liu, Cai; Hu, Yingsa; Zhang, Ling; Hu, Zuzhi; Yang, Hui
2017-12-01
In the exploration and evaluation of the metalliferous veins with a cross-borehole radar system, traditional linear inversion methods (least squares inversion, LSQR) only get indirect parameters (permittivity, resistivity, or velocity) to estimate the target structure. They cannot accurately reflect the geological parameters of the metalliferous veins’ media properties. In order to get the intrinsic geological parameters and internal distribution, in this paper, we build a metalliferous veins model based on the stochastic effective medium theory, and carry out stochastic inversion and parameter estimation based on the Monte Carlo sampling algorithm. Compared with conventional LSQR, the stochastic inversion can get higher resolution inversion permittivity and velocity of the target body. We can estimate more accurately the distribution characteristics of abnormality and target internal parameters. It provides a new research idea to evaluate the properties of complex target media.
Portal vein aneurysm: What to know.
Laurenzi, Andrea; Ettorre, Giuseppe Maria; Lionetti, Raffaella; Meniconi, Roberto Luca; Colasanti, Marco; Vennarecci, Giovanni
2015-11-01
Portal vein aneurysm is an unusual vascular dilatation of the portal vein, which was first described by Barzilai and Kleckner in 1956 and since then less than 200 cases have been reported. The aim of this article is to provide an overview of the international literature to better clarify various aspects of this rare nosological entity and provide clear evidence-based summary, when available, of the clinical and surgical management. A systematic literature search of the Pubmed database was performed for all articles related to portal vein aneurysm. All articles published from 1956 to 2014 were examined for a total of 96 reports, including 190 patients. Portal vein aneurysm is defined as a portal vein diameter exceeding 1.9 cm in cirrhotic patients and 1.5 cm in normal livers. It can be congenital or acquired and portal hypertension represents the main cause of the acquired version. Surgical indication is considered in case of rupture, thrombosis or symptomatic aneurysms. Aneurysmectomy and aneurysmorrhaphy are considered in patients with normal liver, while shunt procedures or liver transplantation are the treatment of choice in case of portal hypertension. Being such a rare vascular entity its management should be reserved to high-volume tertiary hepato-biliary centres. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Cowpland, Christine A; Cleese, Amy L; Whiteley, Mark S
2017-06-01
Objectives The objective is to identify the factors that affect the optimal linear endovenous energy density (LEED) to ablate incompetent truncal veins. Methods We performed a literature review of clinical studies, which reported truncal vein ablation rates and LEED. A PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) flow diagram documents the search strategy. We analysed 13 clinical papers which fulfilled the criteria to be able to compare results of great saphenous vein occlusion as defined by venous duplex ultrasound, with the LEED used in the treatment. Results Evidence suggests that the optimal LEED for endovenous laser ablation of the great saphenous vein is >80 J/cm and <100 J/cm in terms of optimal closure rates with minimal side-effects and complications. Longer wavelengths targeting water might have a lower optimal LEED. A LEED <60 J/cm has reduced efficacy regardless of wavelength. The optimal LEED may vary with vein diameter and may be reduced by using specially shaped fibre tips. Laser delivery technique and type as well as the duration time of energy delivery appear to play a role in determining LEED. Conclusion The optimal LEED to ablate an incompetent great saphenous vein appears to be >80 J/cm and <95 J/cm based on current evidence for shorter wavelength lasers. There is evidence that longer wavelength lasers may be effective at LEEDs of <85 J/cm.
Yang, Cheng-Quan; Liu, Yong-Zhong; An, Ji-Cui; Li, Shuang; Jin, Long-Fei; Zhou, Gao-Feng; Wei, Qing-Jiang; Yan, Hui-Qing; Wang, Nan-Nan; Fu, Li-Na; Liu, Xiao; Hu, Xiao-Mei; Yan, Ting-Shuai; Peng, Shu-Ang
2013-01-01
Corky split vein caused by boron (B) deficiency in 'Newhall' Navel Orange was studied in the present research. The boron-deficient citrus exhibited a symptom of corky split vein in mature leaves. Morphologic and anatomical surveys at four representative phases of corky split veins showed that the symptom was the result of vascular hypertrophy. Digital gene expression (DGE) analysis was performed based on the Illumina HiSeq™ 2000 platform, which was applied to analyze the gene expression profilings of corky split veins at four morphologic phases. Over 5.3 million clean reads per library were successfully mapped to the reference database and more than 22897 mapped genes per library were simultaneously obtained. Analysis of the differentially expressed genes (DEGs) revealed that the expressions of genes associated with cytokinin signal transduction, cell division, vascular development, lignin biosynthesis and photosynthesis in corky split veins were all affected. The expressions of WOL and ARR12 involved in the cytokinin signal transduction pathway were up-regulated at 1(st) phase of corky split vein development. Furthermore, the expressions of some cell cycle genes, CYCs and CDKB, and vascular development genes, WOX4 and VND7, were up-regulated at the following 2(nd) and 3(rd) phases. These findings indicated that the cytokinin signal transduction pathway may play a role in initiating symptom observed in our study.
Current reinforcement model reproduces center-in-center vein trajectory of Physarum polycephalum.
Akita, Dai; Schenz, Daniel; Kuroda, Shigeru; Sato, Katsuhiko; Ueda, Kei-Ichi; Nakagaki, Toshiyuki
2017-06-01
Vein networks span the whole body of the amoeboid organism in the plasmodial slime mould Physarum polycephalum, and the network topology is rearranged within an hour in response to spatio-temporal variations of the environment. It has been reported that this tube morphogenesis is capable of solving mazes, and a mathematical model, named the 'current reinforcement rule', was proposed based on the adaptability of the veins. Although it is known that this model works well for reproducing some key characters of the organism's maze-solving behaviour, one important issue is still open: In the real organism, the thick veins tend to trace the shortest possible route by cutting the corners at the turn of corridors, following a center-in-center trajectory, but it has not yet been examined whether this feature also appears in the mathematical model, using corridors of finite width. In this report, we confirm that the mathematical model reproduces the center-in-center trajectory of veins around corners observed in the maze-solving experiment. © 2017 Japanese Society of Developmental Biologists.
Gadzijev, E M; Ravnik, D; Stanisavljevic, D; Trotovsek, B
1997-01-01
The aim of this study was to determine the venous drainage of the dorsal sector of the liver in order to define the differences between segments I and IX and their implications for sectorially and segmentally oriented hepatic surgery. The study was based on corrosion casts of 61 macroscopically healthy livers. The drainage pathways of veins at least 10 mm long and 1 mm wide were evaluated and statistically analysed. On average, 9 veins drained the two segments and three veins from both segments entered the inferior vena cava. In 95% of cases the veins from segment I drained predominantly into the inferior vena cava, whereas in segment IX this pathway was dominant in only 30% of cases. In 64% of cases a vein originating in segment IX entered the right hepatic v. The difference in the venous drainage of the two segments suggests that segment IX partly belongs to the neighbouring segments and may thus be only a paracaval region of the right liver.
The geology, mineralogy and paragenesis of the Castrovirreyna lead-zinc-silver deposits, Peru
Lewis, Richard Wheatley
1964-01-01
The Castrovirreyna mining district lies in the Andean Cordillera of South Central Peru, and has been worked sporadically since its discovery in 1591. Supergene silver ores were first mined. Currently the district produces about 20,000 tons of lead-zinc ore and 5000 tons of silver ore annually. The district is underlain by Tertiary andesitic rocks interbedded with basalts and intruded by small bodies of quartz latite porphyry. The terrane reflects recent glaciation and is largely covered by glacial debris. The ore deposits are steeply dipping veins that strike N. 60? E. to S. 50? E., and average 60 centimeters wide and 300 meters long. The principal veins are grouped around three centers, lying 5 kilometers apart along a line striking N. 55? E. They are, from east to west: San Genaro, Caudalosa, and La Virreyna. A less important set of veins, similarly aligned, lies 2 kilometers to the north. Most of the veins were worked to depths of about 30 meters, the limit of supergene enrichment; but in the larger veins hypogene ores have been worked to depths of over 150 meters. Galena, sphalerite, chalcopyrite, and tetrahedrite are common to all veins, but are most abundant in the westernmost veins at La Virreyna. In the center of the district, around Caudalosa, land sulfantimonides are the commonest ore minerals, and at the eastern end, around San Genaro and Astohuaraca, silver sulfosalts predominate. Supergene enrichment of silver is found at shallow depths in all deposits. Silver at San Genaro, however, was concentrated towards the surface by migration along hypogene physico-chemical gradients in time and space, as vein material was reworked by mineralizing fluids. The pattern of wallrock alteration throughout the district grades from silicification and scricitization adjacent to the veins, through argillization and propylitization, to widespread chloritization farther away. Mineralization can be divided into three stages: 1) Preparatory stage, characterized by silicification and pyritization; 2) Depositional stage, characterized by the deposition of base-metal sulfides; and 3) Reworking stage, characterized by the formation of lead sulfantimonides from galena at Caudalosa, and the deposition of silver sulfide and sulfosalts at San Genaro. Maximum temperatures, indicated by the wurtzite-sphalerite, famatinite-energite and chalcopyrite-sphalerite assemblages, did not exceed 350? C. The low iron content of sphalerite suggests that most of the base-metal sulfides were deposited below 250? C. The colloidal habits of pyrite and quartz in the preparatory and reworking stages imply relatively low temperatures of deposition, probably between 50? C and 100? C. Mineralization was shallow and pressures ranged from 17 atmospheres in the silver deposits to over 45 atmospheres in the lead sulfantimonide deposits. Mineralization at Castrovirreyna represents an open chemical system in which mineralizing fluids constantly modified the depositional environment while they themselves underwent modification. The deposits formed under nonequilibrium conditions from fluids containing complex ions and colloids. Reworking and migration along persistent physico-chemical gradients in time and space, from a deep source to the west concentrated base-metal sulfides in the western half, lead-antimony minerals in the center, and silver-antimony minerals in the eastern part of the district. Silver, antimony, and bismuth were kept in solution as complex ions until low temperature and pressure prevailed. They document in situ reworking by reacting with existing minerals. Physico-chemical gradients controlled the type of minerals deposited, whereas vein structure controlled the quantity deposited. Vein fissures formed by the equivalent of from east-west compression during Andean orogenesis and mineralization probably came from the underlying Andean Batholith.
Ultrasound Findings in Tension Pneumothorax: A Case Report.
Inocencio, Maxine; Childs, Jeannine; Chilstrom, Mikaela L; Berona, Kristin
2017-06-01
Delayed recognition of tension pneumothorax can lead to a mortality of 31% to 91%. However, the classic physical examination findings of tracheal deviation and distended neck veins are poorly sensitive in the diagnosis of tension pneumothorax. Point-of-care ultrasound is accurate in identifying the presence of pneumothorax, but sonographic findings of tension pneumothorax are less well described. We report the case of a 21-year-old man with sudden-onset left-sided chest pain. He was clinically stable without hypoxia or hypotension, and the initial chest x-ray study showed a large pneumothorax without mediastinal shift. While the patient was awaiting tube thoracostomy, a point-of-care ultrasound demonstrated findings of mediastinal shift and a dilated inferior vena cava (IVC) concerning for tension physiology, even though the patient remained hemodynamically stable. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: This case demonstrates a unique clinical scenario of ultrasound evidence of tension physiology in a clinically stable patient. Although this patient was well appearing without hypotension, respiratory distress, tracheal deviation, or distended neck veins, point-of-care ultrasound revealed mediastinal shift and a plethoric IVC. Given that the classic clinical signs of tension pneumothorax are not uniformly present, this case shows how point-of-care ultrasound may diagnose tension pneumothorax before clinical decompensation. Published by Elsevier Inc.
Qiu, Xue-feng; Dong, Nian-guo; Sun, Zong-quan; Su, Wei; Shi, Jia-wei
2009-07-01
To evaluate the efficacy of using small interfering RNA targeting TF as a therapy for vein graft failure. External jugular vein to carotid artery interposition vein grafts, which were applied to a low flow condition, were made in 120 Sprague-Dawley rats weighing 260 to 300 g. These rats were randomly divided into 4 groups, 30 rats each group. Group A was atelocollagen-TF Stealth Select RNAi group. Group B was atelocollagen-TF Stealth RNAi group. Group C was atelocollagen group. Group D was control group. Small interfering RNA mixed with atelocollagen was administrated to the external wall of grafted veins. The TF protein expression of vein grafts was analyzed by Western blot at 1, 3, 7, 14, and 28 d postoperatively, and by immunochemistry at 3 d postoperatively. The proliferation index was determined at 14 d postoperatively. Neointimal hyperplasia was evaluated at 28 d postoperatively. BLOCK-iT fluorescent oligo was used to confirm its stability and successful transfer into the vein graft wall at 3 and 7 d postoperatively for another group (n=12). Fluorescence of BLOCK-iT fluorescent oligo could be detected in the graft wall even at 7 d postoperatively. Knockdown of the TF expression was achieved by perivascular application of siRNA using atelocollagen. Compared with control group, the intima thickness at 28 d after grafting was significantly reduced (P < 0.05). This phenomenon was preceded by significant reduction of cell proliferation in siRNA-treated grafts at 14 d postoperatively (P < 0.05). The expression of TF in vein grafts can be effectively inhibited by specific siRNAs using a atelocollagen-based nonviral delivery approach in vivo, so that the neointimal thickening can be prevented. Transplants;
18O Spatial Patterns of Vein Xylem Water, Leaf Water, and Dry Matter in Cotton Leaves
Gan, Kim Suan; Wong, Suan Chin; Yong, Jean Wan Hong; Farquhar, Graham Douglas
2002-01-01
Three leaf water models (two-pool model, Péclet effect, and string-of-lakes) were assessed for their robustness in predicting leaf water enrichment and its spatial heterogeneity. This was achieved by studying the 18O spatial patterns of vein xylem water, leaf water, and dry matter in cotton (Gossypium hirsutum) leaves grown at different humidities using new experimental approaches. Vein xylem water was collected from intact transpiring cotton leaves by pressurizing the roots in a pressure chamber, whereas the isotopic content of leaf water was determined without extracting it from fresh leaves with the aid of a purpose-designed leaf punch. Our results indicate that veins have a significant degree of lateral exchange with highly enriched leaf water. Vein xylem water is thus slightly, but progressively enriched in the direction of water flow. Leaf water enrichment is dependent on the relative distances from major veins, with water from the marginal and intercostal regions more enriched and that next to veins and near the leaf base more depleted than the Craig-Gordon modeled enrichment of water at the sites of evaporation. The spatial pattern of leaf water enrichment varies with humidity, as expected from the string-of-lakes model. This pattern is also reflected in leaf dry matter. All three models are realistic, but none could fully account for all of the facets of leaf water enrichment. Our findings acknowledge the presence of capacitance in the ground tissues of vein ribs and highlight the essential need to incorporate Péclet effects into the string-of-lakes model when applying it to leaves. PMID:12376664
Majzoub, A; Elbardisi, H; Arafa, M; Agarwal, A; Al Said, S; Al Rumaihi, K
2016-09-01
Varicocele is a well-established cause of male subfertility, which is directly proportional to its clinical grade. Although newer ultrasonic grading systems have taken into account the existence of pampiniform venous plexi, little is known about the clinical significance of the number of veins ligated during surgery. Very few undersized studies reported an influence which triggered the need to evaluate such association. This is a retrospective study of 378 patients who underwent left microsurgical subinguinal varicocoelectomy. Semen analyses and blood hormone studies performed pre-operatively were compared to those executed 6 months after surgery. Patients were divided into abnormal semen and normal semen groups based on their initial semen results. They were also subdivided according to the number of veins ligated intraoperatively into three groups: <5, 5-10, and >10 veins. Sperm count, total motility, and progressive motility were significantly increased in 62, 60.3, and 53.3% of patients post-operatively (p = 0.001), respectively. No significant differences in hormone levels were detected overall. Of the 378 patients, 332 had an abnormal semen analysis, while the remaining 46 patients had a normal result. Sperm count, total motility, and progressive motility significantly increased after varicocoelectomy in patients with an abnormal initial semen analysis (p = 0.001). In 48.7% of patients, 5-10 veins were ligated during surgery, whereas 28.3% had >10 and 23% had <5 ligated veins. No statistically significant differences were noted in the initial or the follow-up results among the number of vein subgroups. Varicocele ligation improves patients' fertility potential. This improvement, however, is not influenced by the number of veins ligated intraoperatively. Clinical grading maintains its superiority in the evaluation of varicocele patients. © 2016 American Society of Andrology and European Academy of Andrology.
Pulmonary vein stenosis in patients with Smith-Lemli-Opitz syndrome.
Prosnitz, Aaron R; Leopold, Jane; Irons, Mira; Jenkins, Kathy; Roberts, Amy E
2017-07-01
To describe a group of children with co-incident pulmonary vein stenosis and Smith-Lemli-Opitz syndrome and to generate hypotheses as to the shared pathogenesis of these disorders. Retrospective case series. Five subjects in a pulmonary vein stenosis cohort of 170 subjects were diagnosed with Smith-Lemli-Opitz syndrome soon after birth. All five cases were diagnosed with Smith-Lemli-Opitz syndrome within 6 weeks of life, with no family history of either disorder. All cases had pathologically elevated 7-dehydrocholesterol levels and two of the five cases had previously reported pathogenic 7-dehydrocholesterol reductase mutations. Smith-Lemli-Opitz syndrome severity scores ranged from mild to classical (2-7). Gestational age at birth ranged from 35 to 39 weeks. Four of the cases were male by karyotype. Pulmonary vein stenosis was diagnosed in all cases within 2 months of life, earlier than most published cohorts. All cases progressed to bilateral disease and three cases developed atresia of at least one vein. Despite catheter and surgical interventions, all subjects' pulmonary vein stenosis rapidly recurred and progressed. Three of the subjects died, at 2 months, 3 months, and 11 months. Survival at 16 months after diagnosis was 43%. Patients with pulmonary vein stenosis who have a suggestive syndromic presentation should be screened for Smith-Lemli-Opitz syndrome with easily obtainable serum sterol tests. Echocardiograms should be obtained in all newly diagnosed patients with Smith-Lemli-Opitz syndrome, with a low threshold for repeating the study if new respiratory symptoms of uncertain etiology arise. Further studies into the pathophysiology of pulmonary vein stenosis should consider the role of cholesterol-based signaling pathways in the promotion of intimal proliferation. © 2017 Wiley Periodicals, Inc.
Ebneter, Andreas; Agca, Cavit; Dysli, Chantal; Zinkernagel, Martin S.
2015-01-01
Retinal vein occlusion is a leading cause of visual impairment. Experimental models of this condition based on laser photocoagulation of retinal veins have been described and extensively exploited in mammals and larger rodents such as the rat. However, few reports exist on the use of this paradigm in the mouse. The objective of this study was to investigate a model of branch and central retinal vein occlusion in the mouse and characterize in vivo longitudinal retinal morphology alterations using spectral domain optical coherence tomography. Retinal veins were experimentally occluded using laser photocoagulation after intravenous application of Rose Bengal, a photo-activator dye enhancing thrombus formation. Depending on the number of veins occluded, variable amounts of capillary dropout were seen on fluorescein angiography. Vascular endothelial growth factor levels were markedly elevated early and peaked at day one. Retinal thickness measurements with spectral domain optical coherence tomography showed significant swelling (p<0.001) compared to baseline, followed by gradual thinning plateauing two weeks after the experimental intervention (p<0.001). Histological findings at day seven correlated with spectral domain optical coherence tomography imaging. The inner layers were predominantly affected by degeneration with the outer nuclear layer and the photoreceptor outer segments largely preserved. The application of this retinal vein occlusion model in the mouse carries several advantages over its use in other larger species, such as access to a vast range of genetically modified animals. Retinal changes after experimental retinal vein occlusion in this mouse model can be non-invasively quantified by spectral domain optical coherence tomography, and may be used to monitor effects of potential therapeutic interventions. PMID:25775456
Experimental models for Murray’s law
NASA Astrophysics Data System (ADS)
Akita, Dai; Kunita, Itsuki; Fricker, Mark D.; Kuroda, Shigeru; Sato, Katsuhiko; Nakagaki, Toshiyuki
2017-01-01
Transport networks are ubiquitous in multicellular organisms and include leaf veins, fungal mycelia and blood vessels. While transport of materials and signals through the network plays a crucial role in maintaining the living system, the transport capacity of the network can best be understood in terms of hydrodynamics. We report here that plasmodium from the large, single-celled amoeboid Physarum was able to construct a hydrodynamically optimized vein-network when evacuating biomass from confined arenas of various shapes through a narrow exit. Increasingly thick veins developed towards the exit, and the network spanned the arena via repetitive bifurcations to give a branching tree. The Hausdorff distance from all parts of the plasmodium to the vein network was kept low, whilst the hydrodynamic conductivity from distal parts of the network to the exit was equivalent, irrespective of the arena shape. This combination of spatial patterning and differential vein thickening served to evacuate biomass at an equivalent rate across the entire arena. The scaling relationship at the vein branches was determined experimentally to be 2.53-3.29, consistent with predictions from Murray’s law. Furthermore, we show that mathematical models for self-organised, adaptive transport in Physarum simulate the experimental network organisation well if the scaling coefficient of the current-reinforcement rule is set to 3. In simulations, this resulted in rapid development of an optimal network that minimised the combined volume and frictional energy in comparison with other scaling coefficients. This would predict that the boundary shear forces within each vein are constant throughout the network, and would be consistent with a feedback mechanism based on a sensing a threshold shear at the vein wall.
Leg ulceration as a long-term complication of deep vein thrombosis.
Walker, Natalie; Rodgers, Anthony; Birchall, Nicholas; Norton, Robyn; MacMahon, Stephen
2003-12-01
To evaluate the role of deep vein thrombosis as a cause of leg ulcers. A population-based, case-control study was conducted in Central and North Auckland, New Zealand. Cases comprised 241 people aged 40 to 99 years and on the electoral roll, with current leg ulcers (all types). Cases were identified by means of notification from health professionals and by self-referral. Controls were 224 people in the same age group, without leg ulcers, who were selected from the electoral roll by using a stratified random sampling process. The occurrence of leg ulceration as a consequence of exposure to deep vein thrombosis or being at high risk of deep vein thrombosis (that is, people with a family history of deep vein thrombosis, and/or a history of leg fracture and/or hip, leg, or foot surgery). After adjustment for age, sex, and other potential confounding factors, people who had a diagnosed thromboembolism were at almost three times higher risk of having a leg ulcer (odds ratio, 2.92; 95% confidence interval (CI), 1.47 to 6.08). In addition, people who had been at high risk of a venous thrombosis but were not diagnosed with this condition (eg, people with a history of major leg surgery) were also at increased risk of ulceration (odds ratio, 2.25; 95% CI, 1.49-3.42). Overall, 56% (95% CI, 33% - 71%) of leg ulcers were attributed to being at high risk of deep vein thrombosis. Deep vein thrombosis and factors that place people at high risk of deep vein thrombosis are an important cause of leg ulcers in older people. This finding strengthens the rationale for the routine and long-term use of thromboprophylaxis, particularly in high-risk patients.
Gonenc, Berk; Chae, Jeremy; Gehlbach, Peter; Taylor, Russell H.; Iordachita, Iulian
2017-01-01
Retinal vein cannulation is a technically demanding surgical procedure where therapeutic agents are injected into the retinal veins to treat occlusions. The clinical feasibility of this approach has been largely limited by the technical challenges associated with performing the procedure. Among the challenges to successful vein cannulation are identifying the moment of venous puncture, achieving cannulation of the micro-vessel, and maintaining cannulation throughout drug delivery. Recent advances in medical robotics and sensing of tool-tissue interaction forces have the potential to address each of these challenges as well as to prevent tissue trauma, minimize complications, diminish surgeon effort, and ultimately promote successful retinal vein cannulation. In this paper, we develop an assistive system combining a handheld micromanipulator, called “Micron”, with a force-sensing microneedle. Using this system, we examine two distinct methods of precisely detecting the instant of venous puncture. This is based on measured tool-tissue interaction forces and also the tracked position of the needle tip. In addition to the existing tremor canceling function of Micron, a new control method is implemented to actively compensate unintended movements of the operator, and to keep the cannulation device securely inside the vein following cannulation. To demonstrate the capabilities and performance of our uniquely upgraded system, we present a multi-user artificial phantom study with subjects from three different surgical skill levels. Results show that our puncture detection algorithm, when combined with the active positive holding feature enables sustained cannulation which is most evident in smaller veins. Notable is that the active holding function significantly attenuates tool motion in the vein, thereby reduces the trauma during cannulation. PMID:28946634
NASA Astrophysics Data System (ADS)
Vishnu, C. S.; Lahiri, Sivaji; Mamtani, Manish A.
2018-01-01
In this study the importance of rock strength and its anisotropy in controlling vein emplacement is evaluated by integrating anisotropy of magnetic susceptibility (AMS) with rock mechanics data from massive (visibly isotropic) metabasalts of Gadag region (Dharwar Craton, South India). Orientation of magnetic foliation (MF) is first recognized from AMS. Subsequently, rock mechanics tests viz. ultrasonic P-wave velocity (Vp), uniaxial compressive strength (UCS) and point load strength (Is(50)) are done in cores extracted parallel and perpendicular to MF. Vp is found to be higher in direction parallel to MF than perpendicular to it. In contrast rock strength (UCS and Is(50)) is greater in direction perpendicular to MF, than parallel to it. This proves that rocks from the gold mineralized belt of Gadag have rock strength anisotropy. Orientation of MF in Gadag region is NW-SE, which is also the mean orientation of quartz veins. Previous studies indicate that emplacement of veins in the region took place during regional D3 (NW-SE shortening). Based on the present study, it is concluded that vein emplacement took place in NW-SE orientation because the rocks have strength anisotropy and are weaker in this direction (orientation of MF), which dilated to accommodate fluid flow. In addition, vein intensities are measured along three traverses and found to be variable. It is argued that since mineralization is favoured when the system gets saturated with fluid, variation in fluid flow could not have been responsible for variation in vein intensities in the study area. Since the rock strength of the different blocks investigated here is not uniform, it is envisaged that variation in rock strength played an important role in controlling the vein intensities. It is concluded that rock strength variation controlled strain partitioning and channelized fluid flow thus influencing vein emplacement and mineralization and formation of lodes.
NASA Astrophysics Data System (ADS)
Firth, Emily A.; Holwell, David A.; Oliver, Nicholas H. S.; Mortensen, James K.; Rovardi, Matthew P.; Boyce, Adrian J.
2015-08-01
Mineral de Talca is a rare occurrence of Mesozoic, gold-bearing quartz vein mineralisation situated within the Coastal Range of northern Chile. Quartz veins controlled by NNW-SSE-trending faults are hosted by Devonian-Carboniferous metasediments of greenschist facies and younger, undeformed granitoid and gabbro intrusions. The principal structural control in the area is the easterly dipping, NNW-SSE-trending El Teniente Fault, which most likely developed as an extensional normal fault in the Triassic but was later reactivated as a strike-slip fault during subsequent compression. A dilational zone in the El Teniente Fault appears to have focussed fluid flow, and an array of NW-SE-trending veins is present as splays off the El Teniente Fault. Mineralised quartz veins typically up to a metre thick occur in three main orientations: (1) parallel to and within NNW-SSE-trending, E-dipping faults throughout the area; (2) along NW-SE-trending, NE-dipping structures which may also host andesite dykes; and (3) rarer E-W-trending, subvertical veins. All mineralised quartz veins show evidence of multiple fluid events with anastomosing and crosscutting veins and veinlets, some of which contain up to 3.5 vol.% base metal sulphides. Mineralogically, Au is present in three textural occurrences, identified by 3D CT scanning: (1) with arsenopyrite and pyrite in altered wall rock and along the margins of some of the veins; (2) with Cu-Pb-Zn sulphides within quartz veins; and (3) as nuggets and clusters of native Au within quartz. Fluid inclusion work indicates the presence of CO2-CH4-bearing fluids with homogenisation temperatures of ˜350 °C and aqueous fluids with low-moderate salinities (0.4-15.5 wt% NaCl eq.) with homogenisation temperatures in the range of 161-321 °C. The presence of Au with arsenopyrite and pyrite in structurally controlled quartz veins and in greenschist facies rocks with evidence of CO2-bearing fluids is consistent with an orogenic style classification for the mineralisation. However, the significant amounts of base metals and the moderate salinity of some of the fluids and the proximity to felsic granitoid intrusions have raised the possibility of an intrusion-related origin for the mineralisation. Vein sulphides display S isotope signatures (δ34S +2.1 to +4.3 ‰) that are intermediate between the host rock metasediments (δ34S +5.3 to +7.5 ‰) and the local granitoids (δ34S +1.3 to +1.4 ‰), indicating a distinct crustal source of some of the S in the veins and possibly a mixed magmatic-crustal S source. The local granite and granodiorite give U-Pb zircon ages of 219.6 ± 1 and 221.3 ± 2.8 Ma, respectively. Lead isotopic compositions of galena in the veins are consistent, suggesting derivation from a homogeneous source. Differences, however, between the isotopic signatures of the veins and igneous feldspars from nearby intrusions imply that these bodies were not the source of the metals though an igneous source from depth cannot be discounted. The Triassic age of the granitoids is consistent with emplacement during regional crustal extension, with the El Teniente Fault formed as an easterly dipping normal fault. The change to a compressional regime in the mid-Jurassic caused reactivation of the El Teniente Fault as a strike-slip fault and provided a structural setting suitable for orogenic style mineralisation. The intrusions may, however, have provided a structural competency contrast that focused the mineralising fluids in a dilational jog along the El Teniente Fault to form WNW-trending veins. As such, the mineralisation is classified as orogenic style, and the identification of the key mineralogical, isotopic and structural features has implications for exploration and the development of similar deposits along the Coastal Range.
Avramovic, Nemanja; Weckesser, Matthias; Velasco, Aglaé; Stenner, Markus; Noto, Benjamin
2017-02-01
A 60-year-old woman was referred to contrast-enhanced CT for evaluation of jugular vein thrombosis incidentally detected by ultrasound. Contrast-enhanced CT showed an enhanced tumor of the right skull base highly suspicious of jugulotympanic paraganglioma. However, the jugular veins showed a nearly symmetric contrast enhancement without clear evidence of thrombosis. Consecutive Ga-DOTATATE PET/CT depicted high tumor uptake, which comprised the entire internal jugular vein. Endovascular growth of paraganglioma might be missed on contrast-enhanced CT because of high vascularization of the lesion. Ga-DOTATATE PET is suited for accurate determination of tumor extent.
Na, Tong; Xie, Jianyang; Zhao, Yitian; Zhao, Yifan; Liu, Yue; Wang, Yongtian; Liu, Jiang
2018-05-09
Automatic methods of analyzing of retinal vascular networks, such as retinal blood vessel detection, vascular network topology estimation, and arteries/veins classification are of great assistance to the ophthalmologist in terms of diagnosis and treatment of a wide spectrum of diseases. We propose a new framework for precisely segmenting retinal vasculatures, constructing retinal vascular network topology, and separating the arteries and veins. A nonlocal total variation inspired Retinex model is employed to remove the image intensity inhomogeneities and relatively poor contrast. For better generalizability and segmentation performance, a superpixel-based line operator is proposed as to distinguish between lines and the edges, thus allowing more tolerance in the position of the respective contours. The concept of dominant sets clustering is adopted to estimate retinal vessel topology and classify the vessel network into arteries and veins. The proposed segmentation method yields competitive results on three public data sets (STARE, DRIVE, and IOSTAR), and it has superior performance when compared with unsupervised segmentation methods, with accuracy of 0.954, 0.957, and 0.964, respectively. The topology estimation approach has been applied to five public databases (DRIVE,STARE, INSPIRE, IOSTAR, and VICAVR) and achieved high accuracy of 0.830, 0.910, 0.915, 0.928, and 0.889, respectively. The accuracies of arteries/veins classification based on the estimated vascular topology on three public databases (INSPIRE, DRIVE and VICAVR) are 0.90.9, 0.910, and 0.907, respectively. The experimental results show that the proposed framework has effectively addressed crossover problem, a bottleneck issue in segmentation and vascular topology reconstruction. The vascular topology information significantly improves the accuracy on arteries/veins classification. © 2018 American Association of Physicists in Medicine.
Ratchford, Michael E.
2002-01-01
Boulder Basin is in a northwest-trending belt of allochthonous Paleozoic rocks in the Boulder Mountains of central Idaho. Regional Tertiary extension resulted in widespread normal faulting and coeval emplacement of shallow-level intrusions and extrusive rocks of the Challis Volcanic Group. Epigenetic lead-zinc-silver-antimony-tin-gold vein deposits formed during Tertiary extension and are hosted within Paleozoic strata. The major orebodies are in the lower plate of the Boulder Basin thrust fault, in massive quartzite of the Middle Pennsylvanian to Lower Permian Wood River Formation. Anomalous concentrations of tin are present in the base-metal mineral assemblage of the Boulder Basin ore deposits. The tin-bearing veins in Boulder Basin are strikingly similar to Bolivian tin deposits. The deposit model for Bolivian tin deposits identifies buried tin porphyry below the tin-bearing vein system.
Deep venous thrombosis and postthrombotic syndrome: invasive management.
Comerota, A J
2015-03-01
Invasive management of postthrombotic syndrome encompasses the two ends of the deep vein thrombosis spectrum, patients with acute iliofemoral deep vein thrombosis and those with chronic postthrombotic iliofemoral venous obstruction. Of all patients with acute deep vein thrombosis, those with involvement of the iliofemoral segments have the most severe chronic postthrombotic morbidity. Catheter-based techniques now permit percutaneous treatment to eliminate thrombus, restore patency, potentially maintain valvular function, and improve quality of life. Randomized trial data support an initial treatment strategy of thrombus removal. Failure to eliminate acute thrombus from the iliofemoral system leads to chronic postthrombotic obstruction of venous outflow. Debilitating chronic postthrombotic symptoms of the long-standing obstruction of venous outflow can be reduced by restoring unobstructed venous drainage from the profunda femoris vein to the vena cava. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
NASA Astrophysics Data System (ADS)
Kouzmanov, Kalin; Bailly, Laurent; Ramboz, Claire; Rouer, Olivier; Bény, Jean-Michel
2002-08-01
Pyrite samples from the Radka epithermal, replacement type, volcanic rock-hosted copper deposit, Bulgaria, have been studied using near-infrared (IR) microscopy. Two generations of pyrite based on their textures, composition and behaviour in IR light can be distinguished. Electron microprobe analyses, X-ray elemental mapping and Fourier transform infrared spectroscopy were used to study the relationship between crystal zoning, trace element contents and IR transmittance of pyrite. The observed crystal zoning is related to variable arsenic contents in massive fine-grained and colloform pyrite from the early pyrite-quartz assemblage, and cobalt contents in pyrite crystals from the late quartz-pyrite vein assemblage. There is a negative correlation between trace element content and IR transmittance of pyrite. The IR transparency of pyrite is thus a sensitive indicator of changes in trace element concentrations. Fluid inclusions have only been found in the second pyrite generation. Scanning electron microscopy observations on open fluid inclusion cavities permitted the crystallographic features of vacuoles to be determined. A characteristic feature of primary fluid inclusions in pyrite is a negative crystal habit, shaped mainly by {100}, {111} and {210}. This complicated polyhedral morphology is the reason for the observed opacity of some isometric primary inclusions. Secondary fluid inclusion morphology depends on the nature of the surface of the healed fracture. Recognition of the primary or secondary origin of fluid inclusions is enhanced by using crystallographically oriented sections. Microthermometric measurements of primary inclusions indicate that the second pyrite generation was deposited at maximum P-T conditions of 400 °C and 430 bar and from a fluid of low bulk salinity (3.5-4.6 wt%), possibly KCl-dominant. There are large ranges for homogenisation temperatures in secondary inclusions because of necking-down processes. Decrepitation features of some of pyrite-hosted inclusions and of all inclusions in associated quartz indicate reheating of the veins to 500-550 °C. The late cobalt-rich quartz-pyrite vein assemblage in the Radka deposit may be the shallow manifestation of deeper and genetically related porphyry copper mineralisation. This is a common observation of many intermediate- to high-sulfidation epithermal replacement-type ore bodies in this ore district and possibly the Cretaceous Banat-Srednogorie metallogenic belt in general.
NASA Astrophysics Data System (ADS)
Sawyer, W.; Resor, P. G.
2016-12-01
Pseudotachylyte, a fault rock formed through coseismic frictional melting, provides an important record of coseismic mechanics. In particular, injection veins formed at a high angle to the fault surface have been used to estimate rupture directivity, velocity, pulse length, stress and strength drop, as well as slip weakening distance and wall rock stiffness. These studies, however, have generally treated injection vein formation as a purely elastic process and have assumed that processes of melt generation, transport, and solidification have little influence on the final vein geometry. Using a modified analytical approximation of injection vein formation based on a dike intrusion model we find that the timescales of quenching and flow propagation are similar for a composite set of injection veins compiled from the Asbestos Mountain Fault, USA (Rowe et al., 2012), Gole Larghe Fault Zone, Italy (Griffith et al., 2012) and the Fort Foster Brittle Zone. This indicates a complex, dynamic process whose behavior is not fully captured by the current approach. To assess the applicability of the simplifying assumptions of the dike model when applied to injection veins we employ a finite-element time-dependent model of injection vein formation. This model couples elastic deformation of the wall rock with the fluid dynamics and heat transfer of the frictional melt. The final geometry of many injection veins is unaffected by the inclusion of these processes. However, some injection veins are found to be flow limited, with a final geometry reflecting cooling of the vein before it reaches an elastic equilibrium with the wall rock. In these cases, numerical results are significantly different from the dike model, and two basic assumptions of the dike model, self-similar growth and a uniform pressure gradient, are shown to be false. Additionally, we apply the finite-element model to provide two new constraints on the Fort Foster coseismic environment: a lower limit on the initial melt temperature of 1400 *C, and either significant coseismic wall rock softening or high transient tensile stress.
Wall-rock control of cortain pitchblende deposits in Golden Gate Canyon, Jefferson County, Colorado
Adams, John W.; Stugard, Frederick
1954-01-01
Carbonate veins cutting pre-Cambrian metamorphic rocks in Golden Gate Canyon contain pitchblende and base-metal sulfides. The veins occupy extensive faults of Laramide age but normally contain pitchblende only where the cut hornblende gneiss. At the Union Pacific prospect, which was studied in detail, pitchblende, hermatite, and some ankerite formed in advance of sulfides, except possibly for minor pyrite. Base-metal sulfides and the bulk of ankerite-calcite vein-filling were deposited after the pitchblende. Chemical analyses show a high ferrous iron content in the hornblende gneiss in contrast to low ferrous iron in the adjacent biotite gneiss. It is hypothesized that ferrous iron released by alteration of hornblende was partly oxidized to hematite by the ore-bearing solutions and, contemporaneously, uranium was reduced and deposited as pitchblende. In other veins, biotite or iron sulfides may have been similarly effective in precipitating pitchblende. Apparently both the ferrous ion and the sulfide ion can serve as reducing agents and control pitchblende deposition. It is suggested that conditions particularly favorable for uranium deposition are present where uranium-bearing solutions had access to rocks rich in ferrous iron or pre-existing sulfides.
Deep Venous Thrombosis: An Interventionalist's Approach
Jenkins, J. Stephen; Michael, Paul
2014-01-01
Background Deep venous thrombosis (DVT) of the lower extremity has traditionally been anatomically categorized into proximal DVT (thrombosis involving the popliteal vein and above) and distal DVT (isolated calf vein thrombosis). Proximal DVT involving the common femoral and/or iliac veins, referred to as iliofemoral DVT (IFDVT), represents a disease process with a worse prognosis and higher risk for poor clinical outcomes compared to proximal DVT not involving the common femoral or iliac draining veins. Methods This review discusses therapeutic options for treatment of lower extremity IFDVT, including adjuvant anticoagulation and catheter-based invasive therapies; literature supporting current acute interventional techniques; and the recommendations from the recently published American Heart Association guidelines. Results Patients with IFDVT represent an opportune subset of patients for acute interventional management with currently available techniques. This subset of patients with proximal DVT has a worse prognosis, is less well studied, and benefits more from acute intervention compared to patients with proximal DVT or distal DVT. Conclusion Invasive catheter-based therapies that remove thrombus and correct venous outflow obstructions improve outcomes and morbidity in patients with IFDVT. Future trials that address IFDVT specifically will improve our understanding and the proper management of this higher-risk subset of patients with DVT. PMID:25598728
Recognition and Quantification of Area Damaged by Oligonychus Perseae in Avocado Leaves
NASA Astrophysics Data System (ADS)
Díaz, Gloria; Romero, Eduardo; Boyero, Juan R.; Malpica, Norberto
The measure of leaf damage is a basic tool in plant epidemiology research. Measuring the area of a great number of leaves is subjective and time consuming. We investigate the use of machine learning approaches for the objective segmentation and quantification of leaf area damaged by mites in avocado leaves. After extraction of the leaf veins, pixels are labeled with a look-up table generated using a Support Vector Machine with a polynomial kernel of degree 3, on the chrominance components of YCrCb color space. Spatial information is included in the segmentation process by rating the degree of membership to a certain class and the homogeneity of the classified region. Results are presented on real images with different degrees of damage.
Use of the high-resolution satellite images for detection of fractures related to the ore deposits
NASA Astrophysics Data System (ADS)
Cruz-Mondaca, M.; Soto-Pinto, C. A.; Arellano-Baeza, A. A.
2012-12-01
The Aster and GeoEye satellite high-resolution images were used to detect the structures related to the fracturing of the upper crust in the North of Chile. In particular, lineament analysis has been applied to detect the presence of epithermal fluids of low sulfurization associated with the Paleozoic ore deposits. These results have been compared with the location of the minerals altered by the presence of geothermal fluids detected using the spectral libraries. Later, the presence of fractures has been corroborated during recognition of fractures in situ and the geochemical analysis of samples of minerals altered by the presence of fluids. It was shown that the results obtained are relevant for the gold vein detection.
Preliminary report on the Comet area, Jefferson County, Montana
Becraft, George Earle
1953-01-01
Several radioactivity anomalies and a few specimens of sooty pitchblende and other uranium minerals have been found on the mine dumps of formerly productive base- and precious-metal mines along the Comet-Gray Eagle shear zone in the Comet area in southwestern Montana. The shear zone is from 50 to 200 feet wide and has been traced for at least 5? miles. It trends N. 80 ? W. across the northern part of the area and cuts the quartz monzonitic rocks of the Boulder batholith and younger silicic intrusive rocks, as well as prebatholithic volcanic rocks, and is in turn cut by dacite and andesite dikes. The youngest period of mineralization is represented by chalcedonic vein zones comprising one or more discontinuous stringers and veins of cryptocrystalline silica in silicified quartz monzonite and in alaskite that has not been appreciably silicified. In some places these zones contain no distinct chalcedonic veins but are represented only by silicified quartz monzonite. These zones locally contain uranium in association with very small amounts of pyrite, galena, ruby silver, arqentite, native silver, molybdenite, chalcopyrite, arsenopyrite, and barite. At the Free Enterprise mine, uranium has been produced from a narrow chalcedonic vein that contains disseminated secondary uranium minerals and local small pods of pitchblende and also from disseminated secondary uranium ,minerals in the adjacent quartz monzonite. Undiscovered deposits of uranium ore may occur spatially associated with the base- and precious-metal deposits along the Comet-Gray Eagle shear zone and with chalcedonic vein zones similar to the Free Enterprise.
Singhal, Dhruv; Smorodinsky, Emmanuil; Guo, Lifei
2011-01-01
Microvascular reconstructive surgery has seen a revival with the introduction of muscle-sparing perforator flaps. Recognition of potential ethnic differences in coagulation profiles would be important to a microvascular surgeon. Based on clinical observations, we hypothesize that Asian patients have a less thrombogenic coagulation profile than Caucasians. An extensive retrospective review was performed. The annual incidence of venous thromboembolism in the United States is generally accepted to range from 70 to 120 events per 100,000 people versus 16 to 17 events per 100,000 persons in Asia. Autopsy analysis of pulmonary embolism incidence was noted to be 15% in North Americans and less than 1% in Asian populations. Thromboelastography analysis of Asian and Caucasian patients undergoing cholecystectomy revealed different hemostatic mechanisms. Comparison of Asians and Caucasians undergoing the Fontan procedure revealed significantly lower postoperative factor levels in Asians than Caucasians. Baseline comparison of factor and serum levels revealed Asians with the least thrombogenic profiles compared with other ethnic groups. Asians and Caucasians demonstrate different baseline rates of deep vein thrombosis and pulmonary embolism, different hemostatic responses to surgery, and different baseline levels of clotting factors. Further study may lead to better pre-, intra-, and postoperative care of the free flap patient based on their ethnic coagulation profile. © Thieme Medical Publishers.
NASA Astrophysics Data System (ADS)
Garza, Roberto S. Molina; Geissman, John; Wawrzyniec, Tim; Weber, Bodo; Martínez, Margarita López; Aranda-Gómez, Jorge
2009-06-01
The Permian age Chiapas Massif in southeast Mexico is locally host to well-exposed pseudotachylyte vein networks. The veins are black to dark grey and aphanitic in appearance, and consist mostly of microbreccia of angular fragments of plagioclase, K-feldspar, biotite and quartz, in a cryptocrystalline (microscopically irresolvable) matrix. Evidence of melting is present in the form of glass seams, dikelets, glass clasts included in cataclasite and a distinct chemistry in the pseudotachylite veins; pristine glass represents a relatively small volume of the pseudotachylite veins. At an exposure along the Tablón River valley, where the host rock is a medium to coarse-grained equigranular quartz diorite, individual veins are consistently oriented about 280°, are up to 16 mm wide, tens of cm apart, display a consistent left-lateral offset and can be traced for several metres. Individual pseudotachylyte veins rarely cross each other, and they cannot be directly linked to a regional-scale fault. Pseudotachylytes are apparently formed by a combination of crushing, comminution and frictional melting, but they are cataclasite dominated. Textures indicate that cataclasis continued after frictional melting had ceased. A 40Ar/39Ar age determination from whole rock chips of one vein shows a climbing Ar release spectrum with a date of ~114 Ma as the most reliable age estimate for Ar retention. This result is interpreted in the context of pseudotachylyte formation, recrystallization and resetting of K-bearing minerals for the K-Ar system in the late Early Cretaceous. Ten veins were sampled for palaeomagnetic and magnetic fabric studies, with samples collected from both the veins and their host rock. Remanence data give moderate natural remanent magnetization (NRM) intensities for both the veins (e.g. NRM mean 6.6 × 10-3 A m-1 σ = 5.5) and host rock (mean 7.7 × 10-3 A m-1 σ = 10.8). Many samples of host rock yield an ill-defined east-west directed and shallow magnetization, which we interpret as a Late Permian magnetization based on previous studies of the Chiapas Massif. This magnetization resides in haematite. Veins, as well as immediately adjacent host rock, typically have well-defined, single polarity magnetizations of north-northwest declination and moderate positive inclination and these resemble the Cretaceous expected field direction. The overall mean of the veins is of Dec = 348.7° and Inc = 33.6° (k = 30.5 and α95 = 12.3° n = 6 site means). Rock magnetic parameters suggest that the remanence in the veins principally resides in low-Ti pseudo-single domain magnetite and maghemite grains, but haematite, coarse-grained magnetite, rutile, Fe-Cr-Ni oxides and ilmenite are also present in the veins. Bulk magnetic susceptibility values range between ~0.3 and 1.1 * 10-3 SI volume units, and host rock values do not differ significantly from vein values. The orientations of the principal susceptibility axes in the host rock and the veins are indistinguishable. In both, magnetic foliations are near vertical and are essentially parallel to the nearly east-west orientation of the veins. Nonetheless, host rock fabrics are predominantly prolate, whereas vein fabrics are oblate. The mean susceptibility tensors of host rocks and pseudotachylyte are characterized by P'/T values of 1.041/-0.327 and 1.033/+0.302, respectively. This result suggests that the fabric reflected by magnetic susceptibility anisotropy in the veins was formed under pure shear stress, during cooling of the veins. The lack of evidence of fabric rotation supports models that associate partial melt with viscous break during fault slip.
Uranium deposits of the northern part of the Boulder Batholith, Montana
Becraft, George E.
1955-01-01
Uranium minerals and radioactivity anomalies occur in many silver-lead veins and chalcedony veins and vein zones in the Boulder batholith of southwestern Montanao Pitchblende has been identified in a few silver-lead veins. These veins occupy shear zones along which there is no evidence of large-scale lateral displacement. The wall rock adjacent to the veins is intensely silicified and sencitized quartz monzonite and granodiortte. The veins have yielded substantial quantities of lead, silver, zinc, and gold. The silver-lead veins consist principal1y of galena, spha1erite, tetrahedrite, cha1copyrite and pyrite in a gangue of light to dark gray quartz, altered rock, gouge, and subordinate chalcedony and carbonate minerals. No anomalous radioactivity nor uranium minerals have been found in similar veins in pre-batholithic rocks of the area. Chalcedony veins and vein zones, some of which are ttraniferous, are distinctly different from the silver-lead veins and, with a single except1on, are known only in the batholith. The chalcedony vein zones consist of one or more discontinuous stringers or veins of cha1cedony and microcrystalline quartz in silicified and sericitized quartz monzonite and granodiorite, and in less strongly altered alaskite. On1y small amounts of silver ore have been produced from these chalcedony veins and vein zones. All of the veins are ear1y Tertiary in age, but the silver-lead veins probably are older than the chalcedony veins. Uranium is closely associated with chalcedory and microcrystalline quartz in both types of veins. This association suggests that all of the uranium in the area is of the same age. If so, some of the silver-lead veins must have been reopened during the period of chalcedony vein formation.
Design method of ARM based embedded iris recognition system
NASA Astrophysics Data System (ADS)
Wang, Yuanbo; He, Yuqing; Hou, Yushi; Liu, Ting
2008-03-01
With the advantages of non-invasiveness, uniqueness, stability and low false recognition rate, iris recognition has been successfully applied in many fields. Up to now, most of the iris recognition systems are based on PC. However, a PC is not portable and it needs more power. In this paper, we proposed an embedded iris recognition system based on ARM. Considering the requirements of iris image acquisition and recognition algorithm, we analyzed the design method of the iris image acquisition module, designed the ARM processing module and its peripherals, studied the Linux platform and the recognition algorithm based on this platform, finally actualized the design method of ARM-based iris imaging and recognition system. Experimental results show that the ARM platform we used is fast enough to run the iris recognition algorithm, and the data stream can flow smoothly between the camera and the ARM chip based on the embedded Linux system. It's an effective method of using ARM to actualize portable embedded iris recognition system.
Prognostic features and clinical presentation of acute idiopathic enterocolitis in horses
Staempfli, Henry R.; Townsend, Hugh G.G.; Prescott, John F.
1991-01-01
Clinical and hematological changes observed on presentation of 47 horses referred to the Ontario Veterinary College with acute idiopathic colitis were analyzed for their prognostic features. Cases of acute enterocolitis were characterized by fever, dehydration, abnormalities of serum electrolyte concentrations, azotemia, hypoalbuminemia, and increased serum concentrations of muscle enzymes. Severely dehydrated horses were seven times more likely to die or be euthanized than those that were not dehydrated. Other factors associated with failure to survive included the following: increased hematocrit, increased number of band neutrophils, increased serum creatinine and urea concentrations, and decreased blood pH and increasingly negative base excess. The results of multivariate variable analysis (stepwise logistic regression) suggested that, among the variables tested, base excess was the best predictor of death or survival. Twenty of 47 horses died or were euthanized. Reasons for death or euthanasia included: severe disseminated intravascular coagulation, unresponsiveness of severe metabolic acidosis and hypoproteinemia to treatments, and severity of colonic lesions on exploratory laparotomy. Of the surviving horses, three developed chronic laminitis (two were destroyed) and five developed jugular vein thrombosis. Fourteen of 16 horses for which subsequent histories were available returned to normal function. Early recognition of the disease, combined with early and aggressive correction of dehydration and of acid-base imbalance, may be important determinants of survival in horses with acute idiopathic colitis. PMID:17423769
NASA Astrophysics Data System (ADS)
Ding, W.; Chen, Y.
2016-12-01
Eighteen calcium carbonate veins within the igneous basement recovered close to the fossil spreading ridge of the South China Sea during the Integrated Ocean Drilling Program (IODP) Expedition 349 were investigated. These carbonates are of primarily either calcite or aragonite, or some mixed aragonite and calcite, with rarely ankerite. The chemical (Ca, Mg, Sr, Mn, Fe) contents and isotopic (87Sr/86Sr, δ18O, δ18C) compositions of the veins were determined to study the evolving chemistry of hydrothermal fluids and to constrain the timing of vein formation. The carbonate δ18O values range from -5.0 to -0.2 ‰ PDB, indicating these are typical low temperature basement carbonates. Chemical analyses show distinct Mg/Ca and Sr/Ca ratios for aragonite and calcite. 87Sr/86Sr ratios show negative correlations with both the depth and δ18O-calculated formation temperature, and are independent of mineralogy with both aragonite and calcite, indicating more geochemically evolved carbonated have precipitated from warmer fluids. The hightest 87Sr/86Sr ratios of vein samples at each drill site are believed to reflect the contemporaneous seawater compositions when carbonates precipitated. No unambiguous precipitation ages can be constrained by correlating 87Sr/86Sr ratios with the global seawater Sr isotope evolution. However, based on correlations of vein chemical composition with depth and formation temperature, as well as the Neogene post-spreading magmatism, we hypothesize 10 Ma is a particular time favoring the formation of carbonate veins in our study area.
Automatic classification of retinal vessels into arteries and veins
NASA Astrophysics Data System (ADS)
Niemeijer, Meindert; van Ginneken, Bram; Abràmoff, Michael D.
2009-02-01
Separating the retinal vascular tree into arteries and veins is important for quantifying vessel changes that preferentially affect either the veins or the arteries. For example the ratio of arterial to venous diameter, the retinal a/v ratio, is well established to be predictive of stroke and other cardiovascular events in adults, as well as the staging of retinopathy of prematurity in premature infants. This work presents a supervised, automatic method that can determine whether a vessel is an artery or a vein based on intensity and derivative information. After thinning of the vessel segmentation, vessel crossing and bifurcation points are removed leaving a set of vessel segments containing centerline pixels. A set of features is extracted from each centerline pixel and using these each is assigned a soft label indicating the likelihood that it is part of a vein. As all centerline pixels in a connected segment should be the same type we average the soft labels and assign this average label to each centerline pixel in the segment. We train and test the algorithm using the data (40 color fundus photographs) from the DRIVE database1 with an enhanced reference standard. In the enhanced reference standard a fellowship trained retinal specialist (MDA) labeled all vessels for which it was possible to visually determine whether it was a vein or an artery. After applying the proposed method to the 20 images of the DRIVE test set we obtained an area under the receiver operator characteristic (ROC) curve of 0.88 for correctly assigning centerline pixels to either the vein or artery classes.
Infrared imaging of subcutaneous veins.
Zharov, Vladimir P; Ferguson, Scott; Eidt, John F; Howard, Paul C; Fink, Louis M; Waner, Milton
2004-01-01
Imaging of subcutaneous veins is important in many applications, such as gaining venous access and vascular surgery. Despite a long history of medical infrared (IR) photography and imaging, this technique is not widely used for this purpose. Here we revisited and explored the capability of near-IR imaging to visualize subcutaneous structures, with a focus on diagnostics of superficial veins. An IR device comprising a head-mounted IR LED array (880 nm), a small conventional CCD camera (Toshiba Ik-mui, Tokyo, Japan), virtual-reality optics, polarizers, filters, and diffusers was used in vivo to obtain images of different subcutaneous structures. The same device was used to estimate the IR image quality as a function of wavelength produced by a tunable xenon lamp-based monochrometer in the range of 500-1,000 nm and continuous-wave Nd:YAG (1.06 microm) and diode (805 nm) lasers. The various modes of optical illumination were compared in vivo. Contrast of the IR images in the reflectance mode was measured in the near-IR spectral range of 650-1,060 nm. Using the LED array, various IR images were obtained in vivo, including images of vein structure in a pigmented, fatty forearm, varicose leg veins, and vascular lesions of the tongue. Imaging in the near-IR range (880-930 nm) provides relatively good contrast of subcutaneous veins, underscoring its value for diagnosis. This technique has the potential for the diagnosis of varicose veins with a diameter of 0.5-2 mm at a depth of 1-3 mm, guidance of venous access, podiatry, phlebotomy, injection sclerotherapy, and control of laser interstitial therapy. Copyright 2004 Wiley-Liss, Inc.
Gushki, Roghayeh Shamsi; Lashkari, Mohammadreza; Mirzaei, Saeid
2018-01-01
Abstract Jumping plant lice (Hemiptera: Psylloidea) are considered important vectors of plant diseases and also economically important pests in agriculture and forest ecosystems. Three psyllid species Psyllopsis repens Loginova, 1963, Psyllopsis securicola Loginova, 1963, and Psyllopsis machinosus Loginova, 1963 associated with the ash tree Fraxinus are morphologically very similar. So far, their distinction has been possible only by comparing their male and female genitalia. In this research, forewing shape and size characteristics, sexual dimorphism and their allometric effects, using geometric morphometric analysis, were examined for identification purposes. The results showed significant differences in wing shape and size between the species studied. Based on the results, two species P. machinosus and P. securicola can be differentiated with the vein M1+2, as in P. securicola the vein M1+2 is located between Rs and M3+4 veins, but the vein M1+2 is closer to the vein M3+4 in P. machinosus; also, P. repens can be differentiated from the two species P. machinosus and P. securicola by vein M. Hence, the veins M1+2, M3+4, Rs and M were the most important wing characters for discrimination of the three species, especially in the field. The analysis also showed significant differences in wing shape and size between male and female of the three species, and the allometric analysis showed that significant shape differences still remain in constant size in P. machinosus and P. repens. Geometric changes in the forewings of both sexes for the three species are illustrated. PMID:29674872
Corrosion cast study of the canine hepatic veins.
Uršič, M; Vrecl, M; Fazarinc, G
2014-11-01
This study presents a detailed description of the distribution, diameters and drainage patterns of hepatic veins on the basis of the corrosion cast analysis in 18 dogs. We classified the hepatic veins in three main groups: the right hepatic veins of the caudate process and right lateral liver lobe, the middle hepatic veins of the right medial and quadrate lobes and the left hepatic veins of both left liver lobes and the papillary process. The corrosion cast study showed that the number of the veins in the Nomina Anatomica Veterinaria and most anatomical textbooks is underestimated. The number of various-sized hepatic veins of the right liver division ranged from 3 to 5 and included 1 to 4 veins from the caudate process and 2 to 4 veins from the right lateral liver lobe. Generally, in all corrosion casts, one middle-sized vein from the right part of the right medial lobe, which emptied separately in the caudal vena cava, was established. The other vein was a large-sized vein from the remainder of the central division, which frequently joined the common left hepatic vein from the left liver lobes. The common left hepatic vein was the largest of all the aforementioned hepatic veins.
Ro, Ayako; Kageyama, Norimasa; Mukai, Toshiji
2017-06-25
Here the pathophysiology of venous thromboembolism is reviewed with respect to the anatomical features of the deep veins of lower limbs. A thrombus is less likely to form in the thigh veins compared with that in the calf veins; however, clinical symptoms are more likely to appear in the thigh veins owing to vascular occlusion. When a patient is bedridden, thrombosis is more likely to occur in the intramuscular vein, which mainly depends on muscular pumping and the venous valve, rather than in the three crural branches, which mainly depends on the pulsation of the accompanying artery. Thrombi are prone to be generated in the soleal vein compared with those in the gastrocnemius vein because of the vein and muscle structures. A soleal vein thrombosis grows toward the proximal veins along the drainage veins. To prevent a sudden pulmonary thromboembolism-related death in bedridden patients, preventing soleal vein thrombus formation and observing the thrombus proximal propagation via the drainage veins are clinically important. When deep vein thrombosis occurs, avoiding embolization and sequela caused by the thrombus organization is necessary.
Wani, Zeeshan A; Bhat, Riyaz A; Bhadoria, Ajeet S; Maiwall, Rakhi
2015-01-01
Extrahepatic portal vein obstruction is a vascular disorder of liver, which results in obstruction and cavernomatous transformation of portal vein with or without the involvement of intrahepatic portal vein, splenic vein, or superior mesenteric vein. Portal vein obstruction due to chronic liver disease, neoplasm, or postsurgery is a separate entity and is not the same as extrahepatic portal vein obstruction. Patients with extrahepatic portal vein obstruction are generally young and belong mostly to Asian countries. It is therefore very important to define portal vein thrombosis as acute or chronic from management point of view. Portal vein thrombosis in certain situations such as liver transplant and postsurgical/liver transplant period is an evolving area and needs extensive research. There is a need for a new classification, which includes all areas of the entity. In the current review, the most recent literature of extrahepatic portal vein obstruction is reviewed and summarized.
Wani, Zeeshan A.; Bhat, Riyaz A.; Bhadoria, Ajeet S.; Maiwall, Rakhi
2015-01-01
Extrahepatic portal vein obstruction is a vascular disorder of liver, which results in obstruction and cavernomatous transformation of portal vein with or without the involvement of intrahepatic portal vein, splenic vein, or superior mesenteric vein. Portal vein obstruction due to chronic liver disease, neoplasm, or postsurgery is a separate entity and is not the same as extrahepatic portal vein obstruction. Patients with extrahepatic portal vein obstruction are generally young and belong mostly to Asian countries. It is therefore very important to define portal vein thrombosis as acute or chronic from management point of view. Portal vein thrombosis in certain situations such as liver transplant and postsurgical/liver transplant period is an evolving area and needs extensive research. There is a need for a new classification, which includes all areas of the entity. In the current review, the most recent literature of extrahepatic portal vein obstruction is reviewed and summarized. PMID:26021771
Adding New Tools to the Black Bag—Introduction of Ultrasound into the Physical Diagnosis Course
Amponsah, David; Yang, James; Mendez, Jennifer; Bridge, Patrick; Hays, Gregory; Baliga, Sudhir; Crist, Karen; Brennan, Simone; Jackson, Matt; Dulchavsky, Scott
2010-01-01
INTRODUCTION Ultrasound, a versatile diagnostic modality that permits real-time visualization at the patient’s bedside, can be used as an adjunct in teaching physical diagnosis (PD). Aims: (1) to study the feasibility of incorporating ultrasound into PD courses and (2) determine whether learners can demonstrate image recognition and acquisition skills. PROGRAM DESCRIPTION Three hundred seven second-year medical students were introduced to cardiovascular and abdominal ultrasound scanning after training in the physical examination. This consisted of a demonstration of the ultrasound examination, followed by practice on standardized patients (SPs). Pre-post tests were administered to evaluate students’ knowledge and understanding of ultrasound. Students performed an ultrasound examination during the PD final examination. PROGRAM EVALUATION Pre-post test data revealed significant improvements in image recognition. On the final exam, the highest scores (98.4%) were obtained for the internal jugular vein and lowest scores (74.6%) on the Focused Assessment with Sonography for Trauma images. Eighty-nine percent of students’ surveyed felt ultrasound was a valuable tool for physicians. DISCUSSION An introductory ultrasound course is effective in improving medical students' acquisition and recognition of basic cardiovascular and abdominal ultrasound images. This innovative program demonstrates the feasibility of incorporating portable ultrasound as a learning tool during medical school. Electronic supplementary material The online version of this article (doi:10.1007/s11606-010-1451-5) contains supplementary material, which is available to authorized users. PMID:20697974
Kimori, Keiko; Sugama, Junko; Nakatani, Toshio; Nakayama, Kazuya; Miyati, Tosiaki; Sanada, Hiromi
2015-01-01
To compare the performance on the detection of the invisible veins between our modified prototype device and an existing device in elderly hospitalized patients. A prospective, cross-sectional, and observational study was performed in the invisible veins in elderly patients. The major variables, skin color near the invisible veins, and diameter and depth of the invisible veins were measured. The vein visualization rate was calculated as the ratio of the visualized veins to the invisible veins by the visualization device. We analyzed 53 invisible veins in the cubital fossa and 56 invisible veins in the forearm in a total of 72 patients (median age, 73 years). The visualization rate for our prototype device was higher than that for an existing device in the cubital fossa and the forearm sites. The visualized veins of the prototype device had a higher intensity ratio than that of an existing device. No significant differences were observed in the body mass index, vein depth, and vein diameter of the visualized veins at the cubital fossa and forearm sites. The prototype surpassed the existing device in visualizing the invisible veins. However, the prototype was unable to visualize all the invisible veins. We need to look for ways to reduce noise and to visualize the invisible veins, and the visualization rate of devices needs to be investigated in further association with the percentage of success with actual intravenous access and locating time to vein.
NASA Astrophysics Data System (ADS)
Noordmans, Herke J.; Rutten, G. J. M.; Willems, Peter W. A.; Viergever, Max A.
2000-04-01
The visualization of brain vessels on the cortex helps the neurosurgeon in two ways: to avoid blood vessels when specifying the trepanation entry, and to overcome errors in the surgical navigation system due to brain shift. We compared 3D T1, MR, 3D T1 MR with gadolinium contrast, MR venography as scanning techniques, mutual information as registration technique, and thresholding and multi-vessel enhancement as image processing techniques. We evaluated the volume rendered results based on their quality and correspondence with photos took during surgery. It appears that with 3D T1 MR scans, gadolinium is required to show cortical veins. The visibility of small cortical veins is strongly enhanced by subtracting a 3D T1 MR baseline scan, which should be registered to the scan with gadolinium contrast, even when the scans are made during the same session. Multi-vessel enhancement helps to clarify the view on small vessels by reducing noise level, but strikingly does not reveal more. MR venography does show intracerebral veins with high detail, but is, as is, unsuited to show cortical veins due to the low contrast with CSF.
Prevention of deep vein thrombosis and pulmonary embolism. [/sup 125/I
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Quesne, L.P.
1978-03-01
The development of the /sup 125/I-fibrinogen technic in the diagnosis of postoperative deep vein thrombosis provides a valuable tool for the study of the condition itself and of the efficacy of prophylactic measures. These measures may be divided into two groups: the antistasis regimes and the antithrombotic regimes. Published reports based on the /sup 125/I-fibrinogen technic are critically reviewed. Although many regimes cause a significant diminution in the incidence of isotopically detected deep vein thrombosis, 90% of which are confined to the calf, this does not necessarily imply a similar diminution in the incidence of major pulmonary emboli, most ofmore » which arise from thrombi in the proximal segment of the lower limb veins. The origin of these proximal thrombi, with particular reference to their relationship to calf thrombi, is discussed. The reported studies of the influence of antithrombotic regimes on the incidence of pulmonary embolism are reviewed. It is concluded that a reduction in the incidence of isotopically detected deep vein thrombosis is probably accompanied by a significant reduction in the incidence of major pulmonary embolism, but further studies are required.« less
NASA Astrophysics Data System (ADS)
Jaques, Luís; Pascal, Christophe
2017-09-01
Paleostress tensor restoration methods are traditionally limited to reconstructing geometrical parameters and are unable to resolve stress magnitudes. Based on previous studies we further developed a methodology to restore full paleostress tensors. We concentrated on inversion of Mode I fractures and acquired data in Panasqueira Mine, Portugal, where optimal exposures of mineralized quartz veins can be found. To carry out full paleostress restoration we needed to determine (1) pore (paleo)pressure and (2) vein attitudes. The present contribution focuses specifically on the determination of pore pressure. To these aims we conducted an extensive fluid inclusion study to derive fluid isochores from the quartz of the studied veins. To constrain P-T conditions, we combined these isochores with crystallisation temperatures derived from geochemical analyses of coeval arsenopyrite. We also applied the sphalerite geobarometer and considered two other independent pressure indicators. Our results point to pore pressures of ∼300 MPa and formation depths of ∼10 km. Such formation depths are in good agreement with the regional geological evolution. The obtained pore pressure will be merged with vein inversion results, in order to achieve full paleostress tensor restoration, in a forthcoming companion paper.
Photoinduced collagen cross-linking: a new approach to venous insufficiency.
Frullini, Alessandro; Manetti, Leonardo; Di Cicco, Emiliano; Fortuna, Damiano
2011-08-01
What little research has been done on methods of venous valve function recovery with radiofrequency has had disappointing results. Valvuloplasty has some supporters, but the majority of physicians do not consider it a valid therapeutic option. To test a new method of treating varicose veins based on their collagen structure. This procedure it is not a thermal treatment, but it is fast, with significant shrinking and preservation of the endothelium. In the laboratory, we subjected greater saphenous vein specimens to irradiation with a blue light-emitting diode generated (wavelength 450-480 nm) while a riboflavin solution (vitamin B2) was administered. The riboflavin acts as a cross-linking agent, and the blue light as the activator. In this photo-induced reaction, oxygen singlet is produced with oxidative deamination, forming new covalent bonds between collagen fibrils and water. In venous specimens, we demonstrated fast and significant shrinkaged without histologic evidence of endothelial damage and with evident change in mechanical properties of varicose veins. Photochemically induced collagen cross-linking to restructure varicose veins is only a research field but may become an important tool for recovery of vein diameter and valve function. © 2011 by the American Society for Dermatologic Surgery, Inc.
Parsaee, Mozhgan; Pouraliakbar, Hamidreza; Ghadrdoost, Behshid; Moosavi, Jamal; Behjati, Mohaddeseh
2018-06-10
The most commonly reported collateral systems in the setting of superior vena cava obstruction are azygos venous system, vertebral venous system, external and internal thoracic venous system based on McLntire and Sykes classification. A 49-year-old female with renal disease complained dyspnea on exertion. Transesophageal echocardiography showed significant mitral annular calcification, large multi-lobulated mass at posterior aspect of RA, and complete obstruction of superior vena cava by thrombus formation. Computed tomography angiography showed a collateral vein to the left atrium (LA) roof. This case report is the first one which shows development of collateral vein from right subclavian to LA. © 2018 Wiley Periodicals, Inc.
Ro, Ayako; Kageyama, Norimasa; Mukai, Toshiji
2017-01-01
Here the pathophysiology of venous thromboembolism is reviewed with respect to the anatomical features of the deep veins of lower limbs. A thrombus is less likely to form in the thigh veins compared with that in the calf veins; however, clinical symptoms are more likely to appear in the thigh veins owing to vascular occlusion. When a patient is bedridden, thrombosis is more likely to occur in the intramuscular vein, which mainly depends on muscular pumping and the venous valve, rather than in the three crural branches, which mainly depends on the pulsation of the accompanying artery. Thrombi are prone to be generated in the soleal vein compared with those in the gastrocnemius vein because of the vein and muscle structures. A soleal vein thrombosis grows toward the proximal veins along the drainage veins. To prevent a sudden pulmonary thromboembolism-related death in bedridden patients, preventing soleal vein thrombus formation and observing the thrombus proximal propagation via the drainage veins are clinically important. When deep vein thrombosis occurs, avoiding embolization and sequela caused by the thrombus organization is necessary. PMID:29034034
Krishnamoorthy, Bhuvaneswari; Critchley, William R; Nair, Janesh; Malagon, Ignacio; Carey, John; Barnard, James B; Waterworth, Paul D; Venkateswaran, Rajamiyer V; Fildes, James E; Caress, Ann L; Yonan, Nizar
The aim of the study was to assess whether the use of carbon dioxide insufflation has any impact on integrity of long saphenous vein comparing 2 types of endoscopic vein harvesting and traditional open vein harvesting. A total of 301 patients were prospectively randomized into 3 groups. Group 1 control arm of open vein harvesting (n = 101), group 2 closed tunnel (carbon dioxide) endoscopic vein harvesting (n = 100) and Group 3 open tunnel (carbon dioxide) endoscopic vein harvesting (open tunnel endoscopic vein harvesting) (n = 100). Each group was assessed to determine the systemic level of partial arterial carbon dioxide, end-tidal carbon dioxide, and pH. Three blood samples were obtained at baseline, 10 minutes after start of endoscopic vein harvesting, and 10 minutes after the vein was retrieved. Vein samples were taken immediately after vein harvesting without further surgical handling to measure the histological level of endothelial damage. A modified validated endothelial scoring system was used to compare the extent of endothelial stretching and detachment. The level of end-tidal carbon dioxide was maintained in the open tunnel endoscopic vein harvesting and open vein harvesting groups but increased significantly in the closed tunnel endoscopic vein harvesting group (P = 0.451, P = 0.385, and P < 0.001). Interestingly, partial arterial carbon dioxide also did not differ over time in the open tunnel endoscopic vein harvesting group (P = 0.241), whereas partial arterial carbon dioxide reduced significantly over time in the open vein harvesting group (P = 0.001). A profound increase in partial arterial carbon dioxide was observed in the closed tunnel endoscopic vein harvesting group (P < 0.001). Consistent with these patterns, only the closed tunnel endoscopic vein harvesting group demonstrated a sudden drop in pH over time (P < 0.001), whereas pH remained stable for both open tunnel endoscopic vein harvesting and open vein harvesting groups (P = 0.105 and P = 0.869, respectively). Endothelial integrity was better preserved in the open vein harvesting group compared with open tunnel endoscopic vein harvesting or closed tunnel endoscopic vein harvesting groups (P = 0.012) and was not affected by changes in carbon dioxide or low pH. Significantly greater stretching of the endothelium was observed in the open tunnel endoscopic open tunnel endoscopic vein harvesting group compared with the other groups (P = 0.003). This study demonstrated that the different vein harvesting techniques impact on endothelial integrity; however, this does not seem to be related to the increase in systemic absorption of carbon dioxide or to the pressurized endoscopic tunnel. The open tunnel endoscopic harvesting technique vein had more endothelial stretching compared with the closed tunnel endoscopic technique; this may be due to manual dissection of the vein. Further research is required to evaluate the long-term clinical outcome of these vein grafts.
Han, Dongdong; Tang, Rui; Wang, Liang; Li, Ang; Huang, Xin; Shen, Shan; Dong, Jiahong
2017-06-01
Portal vein thrombosis is a complication after liver transplantation and cavernous transformation of the portal vein (CTPV) is a result of portal vein thrombosis, with symptoms of portal hypertension revealed by an enhanced CT scan. Meso-Rex bypass is an artificial shunt connecting the left portal vein to the superior mesenteric vein and is mainly used for idiopathic cavernomas. This technique is also used for post-transplant portal vein thrombosis in pediatric patients thereby bypassing obstructed sites of the extrahepatic portal vein. Here we report about an adult patient who was treated by connecting the cystic part of the portal vein to the splenic vein instead of the superior mesenteric vein. An adult male patient with post-liver transplantation portal vein cavernous transformation suffered from hypersplenism and elevated hepatic enzymes. The last follow up revealed irregular and obvious hypersplenism, and splenomegaly had occurred, while an enhanced CT scan revealed serious esophagogastric varices and CTPV in addition to occluded right and common PV trunks. The patient was treated by connecting the cystic part of the portal vein to the splenic vein instead of the superior mesenteric vein. After the operation, a satisfactory velocity was confirmed 1 month postoperatively and the shunt still remained patent at the 6-month postoperation follow-up. A Meso-Rex bypass intervention connecting the left portal vein to the splenic vein instead of the superior mesenteric vein after liver transplantation in an adult patient with right and common portal vein occlusions has been successfully performed as an alternative approach.
Locating difficult veins for venepuncture and cannulation.
Shaw, Sally Jane
2017-02-15
Vein location and assessment are essential to improve the success rates for vascular access. However, problems remain with first attempt success rates for peripheral cannulation and locating difficult veins. Practitioners may not be aware of developments in technology and aids to assist in the location and assessment of veins to achieve vascular access. This article provides an overview of two vein location aids that can be used to locate difficult veins: the IV-eye vein imager and the Vacuderm tourniquet. It discusses the patient factors that can increase the difficulty of vein assessment and location, and emphasises the importance of vessel health and preservation, and vein palpation. Practitioners should be experienced and skilled in the assessment of veins, and they are encouraged to revisit how they locate and assess veins.
Preliminary report on the Comet area, Jefferson County, Montana
Becraft, George Earle
1952-01-01
Several radioactivity anomalies and a few specimens of sooty pitchblende and other uranium minerals have been found on the mine dumps of formerly productive base-and precious-metal mines along the Comet-Gray Eagle shear zone in the Comet area in southwestern Montana. The shear zone is from 50 to 200 feet wide and has been traced for at least 5 1/2 miles. It trends N. 80° W. across the northern part of the area and cuts the quartz monzonitic rocks of the Boulder batholith and younger silicic intrusive rocks, as well as the pre-batholitic volcanic rocks, and is in turn cut by dacite and andesite dikes. The youngest period of mineralization is represented by chalcedonic vein zones comprising one or more discontinuous stringers and veins of cryptocrystalline silica in silicified quartz monzonite and in alaskite that has not been appreciably silicified. In some places these zones contain no distinct chalcedonic veins, but are represented only by silicified quartz monzonite. These zones locally contain uranium in association with very small amounts of the following minerals: pyrite, galena, ruby silver, argentite, native silver, molybdenite, chalcopyrite, arsenopyrite, and barite. At the Free Enterprise mine, uranium has been produced from a narrow chalcedonic vein that contains disseminated secondary uranium minerals and local small pods of pitchblende and from disseminated secondary uranium minerals in the adjacent quartz monzonite. Undiscovered commercial deposits of uranium ore may occur spatially associated with the base-and precious-metal deposits along the Comet-Gray Eagle shear zone, and chalcedonic vein zones similar to the Free Enterprise.
Suwalski, Grzegorz; Emery, Robert; Mróz, Jakub; Kaczejko, Kamil; Gryszko, Leszek; Cwetsch, Andrzej; Skrobowski, Andrzej
2017-06-01
Concomitant surgical ablation of atrial fibrillation (AF) is recommended for patients undergoing off-pump coronary revascularization in the presence of this arrhythmia. Achievement of optimal visualization of pulmonary veins while maintaining stable haemodynamic conditions is crucial for proper completion of the ablation procedure. This study evaluates the safety and feasibility of right atrial positioning using a suction-based cardiac positioner as opposed to compressive manoeuvres for exposure during off-pump surgical ablation for AF. Thirty-four consecutive patients underwent pulmonary vein isolation, ganglionated plexi ablation and left atrial appendage occlusion during off-pump coronary artery bypass grafting. Right atrial suction positioning was used to visualize right pulmonary veins. Safety and feasibility end points were analysed intraoperatively and in the early postoperative course. In all patients, right atrial positioning created optimal conditions to complete transverse and oblique sinus blunt dissection, correct placement of a bipolar ablation probe, detection and ablation of ganglionated plexi and conduction block assessment. In all patients, this entire right-sided ablation procedure was completed with a single exposure manoeuvre. Feasibility end points were achieved in all study patients. This report documents the safety and feasibility of right atrial exposure using a suction-based cardiac positioner to complete ablation for AF concomitant with off-pump coronary revascularization. This technique may be widely adopted to create stable haemodynamic conditions and optimal visualization of the right pulmonary veins. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Endovascular Radiofrequency Ablation for Varicose Veins
2011-01-01
Executive Summary Objective The objective of the MAS evidence review was to conduct a systematic review of the available evidence on the safety, effectiveness, durability and cost–effectiveness of endovascular radiofrequency ablation (RFA) for the treatment of primary symptomatic varicose veins. Background The Ontario Health Technology Advisory Committee (OHTAC) met on August 26th, 2010 to review the safety, effectiveness, durability, and cost-effectiveness of RFA for the treatment of primary symptomatic varicose veins based on an evidence-based review by the Medical Advisory Secretariat (MAS). Clinical Condition Varicose veins (VV) are tortuous, twisted, or elongated veins. This can be due to existing (inherited) valve dysfunction or decreased vein elasticity (primary venous reflux) or valve damage from prior thrombotic events (secondary venous reflux). The end result is pooling of blood in the veins, increased venous pressure and subsequent vein enlargement. As a result of high venous pressure, branch vessels balloon out leading to varicosities (varicose veins). Symptoms typically affect the lower extremities and include (but are not limited to): aching, swelling, throbbing, night cramps, restless legs, leg fatigue, itching and burning. Left untreated, venous reflux tends to be progressive, often leading to chronic venous insufficiency (CVI). A number of complications are associated with untreated venous reflux: including superficial thrombophlebitis as well as variceal rupture and haemorrhage. CVI often results in chronic skin changes referred to as stasis dermatitis. Stasis dermatitis is comprised of a spectrum of cutaneous abnormalities including edema, hyperpigmentation, eczema, lipodermatosclerosis and stasis ulceration. Ulceration represents the disease end point for severe CVI. CVI is associated with a reduced quality of life particularly in relation to pain, physical function and mobility. In severe cases, VV with ulcers, QOL has been rated to be as bad or worse as other chronic diseases such as back pain and arthritis. Lower limb VV is a very common disease affecting adults – estimated to be the 7th most common reason for physician referral in the US. There is a very strong familial predisposition to VV. The risk in offspring is 90% if both parents affected, 20% when neither affected and 45% (25% boys, 62% girls) if one parent affected. The prevalence of VV worldwide ranges from 5% to 15% among men and 3% to 29% among women varying by the age, gender and ethnicity of the study population, survey methods and disease definition and measurement. The annual incidence of VV estimated from the Framingham Study was reported to be 2.6% among women and 1.9% among men and did not vary within the age range (40-89 years) studied. Approximately 1% of the adult population has a stasis ulcer of venous origin at any one time with 4% at risk. The majority of leg ulcer patients are elderly with simple superficial vein reflux. Stasis ulcers are often lengthy medical problems and can last for several years and, despite effective compression therapy and multilayer bandaging are associated with high recurrence rates. Recent trials involving surgical treatment of superficial vein reflux have resulted in healing and significantly reduced recurrence rates. Endovascular Radiofrequency Ablation for Varicose Veins RFA is an image-guided minimally invasive treatment alternative to surgical stripping of superficial venous reflux. RFA does not require an operating room or general anaesthesia and has been performed in an outpatient setting by a variety of medical specialties including surgeons and interventional radiologists. Rather than surgically removing the vein, RFA works by destroying or ablating the refluxing vein segment using thermal energy delivered through a radiofrequency catheter. Prior to performing RFA, color-flow Doppler ultrasonography is used to confirm and map all areas of venous reflux to devise a safe and effective treatment plan. The RFA procedure involves the introduction of a guide wire into the target vein under ultrasound guidance followed by the insertion of an introducer sheath through which the RFA catheter is advanced. Once satisfactory positioning has been confirmed with ultrasound, a tumescent anaesthetic solution is injected into the soft tissue surrounding the target vein along its entire length. This serves to anaesthetize the vein, insulate the heat from damaging adjacent structures, including nerves and skin and compresses the vein increasing optimal contact of the vessel wall with the electrodes or expanded prongs of the RF device. The RF generator is then activated and the catheter is slowly pulled along the length of the vein. At the end of the procedure, hemostasis is then achieved by applying pressure to the vein entry point. Adequate and proper compression stockings and bandages are applied after the procedure to reduce the risk of venous thromboembolism and to reduce postoperative bruising and tenderness. Patients are encouraged to walk immediately after the procedure. Follow-up protocols vary, with most patients returning 1 to 3 weeks later for an initial follow-up visit. At this point, the initial clinical result is assessed and occlusion of the treated vessels is confirmed with ultrasound. Patients often have a second follow-up visit 1 to 3 months following RFA at which time clinical evaluation and ultrasound are repeated. If required, additional procedures such as phlebectomy or sclerotherapy may be performed during the RFA procedure or at any follow-up visits. Regulatory Status The Closure System® radiofrequency generator for endovascular thermal ablation of varicose veins was approved by Health Canada as a class 3 device in March 2005, registered under medical device license 67865. The RFA intravascular catheter was approved by Health Canada in November 2007 for the ClosureFast catheter, registered under medical device license 16574. The Closure System® also has regulatory approvals in Australia, Europe (CE Mark) and the United States (FDA clearance). In Ontario, RFA is not an insured service and is currently being introduced in private clinics. Methods Literature Search The MAS evidence–based review was performed to support public financing decisions. The literature search was performed on March 9th, 2010 using standard bibliographic databases for studies published up until March, 2010. Inclusion Criteria English language full-reports and human studies Original reports with defined study methodologyReports including standardized measurements on outcome events such as technical success, safety, effectiveness, durability, quality of life or patient satisfaction Reports involving RFA for varicose veins (great or small saphenous veins)Randomized controlled trials (RCTs), systematic reviews and meta-analysesCohort and controlled clinical studies involving ≥ 1 month ultrasound imaging follow-up Exclusion Criteria Non systematic reviews, letters, comments and editorials Reports not involving outcome events such as safety, effectiveness, durability, or patient satisfaction following an intervention with RFAReports not involving interventions with RFA for varicose veinsPilot studies or studies with small samples (< 50 subjects) Summary of Findings The MAS evidence search on the safety and effectiveness of endovascular RFA ablation of VV identified the following evidence: three HTAs, nine systematic reviews, eight randomized controlled trials (five comparing RFA to surgery and three comparing RFA to ELT), five controlled clinical trials and fourteen cohort case series (four were multicenter registry studies). The majority (12⁄14) of the cohort studies (3,664) evaluating RFA for VV involved treatment with first generation RFA catheters and the great saphenous vein (GSV) was the target vessel in all studies. Major adverse events were uncommonly reported and the overall pooled major adverse event rate extracted from the cohort studies was 2.9% (105⁄3,664). Imaging defined treatment effectiveness of vein closure rates were variable ranging from 68% to 96% at post-operative follow-up. Vein ablation rate at 6-month follow-up was reported in four studies with rates close to 90%. Only one study reported vein closure rates at 2 years but only for a minority of the eligible cases. The two studies reporting on RFA ablation with the more efficient second generation catheters involved better follow-up and reported higher ablation rates close to 100% at 6-month follow-up with no major adverse events. A large prospective registry trial that recruited over 1,000 patients at thirty-four largely European centers reported on treatment success in six overlapping reports on selected patient subgroups at various follow-up points up to 5 year. However, the follow-up for eligible recruited patients at all time points was low resulting in inadequate estimates of longer term treatment efficacy. The overall level of evidence of randomized trials comparing RFA with surgical ligation and vein stripping (n = 5) was graded as low to moderate. In all trials RFA ablation was performed with first generation catheters in the setting of the operating theatre under general anaesthesia, usually without tumescent anaesthesia. Procedure times were significantly longer after RFA than surgery. Recovery after treatment was significantly quicker after RFA both with return to usual activity and return to work with on average a one week less of work loss. Major adverse events occurring after surgery were higher [(1.8% (n=4) vs. 0.4% (n = 1) than after RFA but not significantly. Treatment effectiveness measured by imaging defined vein absence or vein closure was comparable in the two treatment groups. Significant improvements in vein symptoms and quality of life over baseline were reported for both treatment groups. Improvements in these outcomes were significantly greater in the RFA group than the surgery group in the peri-operative period but not in later follow-up. Follow-up in these trials was inadequate to evaluate longer term recurrence for either treatment. Patient satisfaction was reported to be high for both treatments but was higher for RFA. The studies comparing endovascular treatment approaches for VV (RFA and ELT) were more limited. Three RCT studies compared RFA (two with the second generation catheter) with ELT but mainly focused on peri-procedural outcomes such as pain, complications and recovery. Vein ablation rates were not evaluated in the trials, except for one small trial involving bilateral VV. Pain responses in patients undergoing ablation were extremely variable and up to 2 weeks, mean pain levels were significantly less with RFA than ELT ablation but differences were not significant at one month. Recovery, evaluated as return to usual activity or return to work, however, was similar in the treatment groups. Vein symptom and QOL improvements were improved in both groups but were significantly better in the RFA group than the ELT group at 2 weeks, but not at one month. Vein ablation rates were evaluated in several controlled clinical studies comparing the treatments between centers or within centers between individuals or over time. Comparisons in these studies were inconsistent with vein ablation rates for RFA reported to be similar to, higher than and lower than those with ELT. Economic Analysis RFA and surgical vein stripping, the main comparator reimbursed by the public system, are comparable in clinical benefits. Hence a cost-analysis was conducted to identify the differences in resources and costs between both procedures and a budgetary impact analysis (BIA) was conducted to project costs over a 5- year period in the province of Ontario. The target population of this economic analysis was patients with symptomatic varicose veins and the primary analytic perspective was that of the Ministry of Health and Long-Term Care. The average case cost (based on Ontario hospital costs and medical resources) for surgical vein stripping was estimated to be $1,799. In order to calculate a procedural cost for RFA it was assumed that the hospital cost and physician labour fees, excluding anaesthesia and surgical assistance, were the same as vein stripping surgery. The manufacturer also provided details on the generator with a capital cost of $27,500 and a lifespan of 5 years and the disposables (catheter, sheath, guidewire) with a cost of $673 per case. The average case cost for RFA was therefore estimated to be $1,356. One-way sensitivity analysis was also conducted with hospital cost of RFA varied to 60% that of vein stripping surgery (average cost per case = $627.08) to calculate an impact to the province. Historical volumes of vein stripping surgeries in Ontario were used to project surgeries in a linear fashion up to five years into the future. Volumes for RFA and ELT were calculated based on share capture from the surgery market based on discussion with clinical expert opinion and existing private data based on discussion with the manufacturer. RFA is expected to compete with ELT and capture some of the market. If ELT is reimbursed by the public sector then numbers will continue to increase from previous private data and share capture from the conventional surgical treatment market. Therefore, RFA cases will also increase since it will be capturing a share of the ELT market. A budget impact to the province was then calculated by multiplying volumes by the cost of the procedure. RFA is comparable in clinical benefits to vein stripping surgery. It has the extra upfront cost of the generator and cost per case for disposables but does not require an operating theater, anaesthetist or surgical assistant fees. The impact to the province is expected to be 5 M by Year 5 with the introduction of new ELT and RFA image guided endovascular technologies and existing surgery for varicose veins. Conclusion The conclusions on the comparative outcomes between endovascular RFA and surgical ligation and saphenous vein stripping and between endovascular RFA and laser ablation for VV treatment are summarized in the table below (ES Table 1). ES Table 1 Outcome comparisons of RFA vs. surgery and RFA vs ELT for varicose veins Outcome Comparisons RFA vs Surgery RFA vs ELT Post procedural pain, minor complications RFA < Surgery RFA < ELT Recovery RFA < Surgery RFA ~ ELT Major adverse events RFA < Surgery RFA ~ ELT Effectiveness - Imaging vein occlusion/ absence RFA ~ Surgery RFA ? ELT Effectiveness -Vein symptom improvement RFA ~ Surgery RFA ~ ELT Effectiveness - Quality Of Life RFA ~ Surgery RFA ~ ELT Recurrence RFA ? Surgery RFA ? ELT Patient satisfaction RFA > Surgery RFA ? ELT Patient preference RFA > Surgery RFA ? ELT Procedure costs RFA < Surgery RFA ~ ELT Budget impact RFA < Surgery RFA ~ ELT ELT refers to endovascular laser ablation; RFA, radiofrequency ablation The outcomes of the evidence-based review on these treatments for VV based on different perspectives are summarized below: RFA First versus Second Generation Catheters and Segmental Ablation Ablation with second generation catheters and segmental ablation offered technical advantages with improved ease and significant decreases in procedure time. RFA ablation with second generation catheters is also no longer restricted to smaller (< 12 mm diameter) saphenous veins. The safety profile with the new device and method of energy delivery is as good as or improved over the first generation device. No major adverse events were reported in two multicenter prospective cohort studies in 6 month follow-up with over 500 patients. Post-operative complications such as bruising and pain were significantly less with RFA ablation with second generation catheters than ELT in two RCT trials.RFA treatment with second generation catheters has ablation rates that are higher than with first generation catheters and are more comparable with the consistently high rates of ELT. Endovascular RFA versus Surgery RFA has a quicker recovery attributable to decreased pain and lower minor complications.RFA, in the short term was comparable to surgery in treatment effectiveness as assessed by imaging defined anatomic outcomes such as vein closure, flow or reflux. Other treatment outcomes such as symptomatic relief and HRQOL were significantly improved in both groups and between group differences in the early peri-operative period were likely influenced by pain experiences. Longer term follow-up was inadequate to evaluate recurrence after either treatment.Patient satisfaction was high after both treatments but was higher for RFA than surgery. Endovascular RFA versus ELT RFA has significantly less post-operative pain than ELT but differences were not significant when pain was adjusted for analgesic use and pain differences between groups did not persist at 1 month follow-up.Treatment effectiveness, measured as symptom relief and QOL improvement were similar between the endovascular treatments in the short term (within 1 month) Treatment effectiveness measured as imaging defined vein ablation was not measured in any RCT trials (only for bilateral VV disease) and results were inconsistently reported in observational trials.Longer term follow-up was not available to assess recurrence after either treatment. System Outcomes – RFA Replacing Surgery or Competing with ELT RFA may offer system advantages in that the treatment can be offered by several medical specialties in outpatient settings and because it does not require an operating theatre or general anaesthesia. The treatment may result in decanting of patients from OR with decreased pre-surgical investigations, demand on anaesthetists’ time, hospital stay and wait time for VV treatment. It may also provide more reliable outpatient scheduling. Procedure costs may be less for endovascular approaches than surgery but the budget impact may be greater with insurance of RFA because of the transfer of cases from the private market to the public payer system.Competition between RFA and ELT endovascular approaches is likely to continue to stimulate innovation and technical changes to advance patient care and result in competitive pricing. PMID:23074413
The anatomy of the cardiac veins in mice
Ciszek, Bogdan; Skubiszewska, Daria; Ratajska, Anna
2007-01-01
Although the cardiac coronary system in mice has been the studied in detail by many research laboratories, knowledge of the cardiac veins remains poor. This is because of the difficulty in marking the venous system with a technique that would allow visualization of these large vessels with thin walls. Here we present the visualization of the coronary venous system by perfusion of latex dye through the right caudal vein. Latex injected intravenously does not penetrate into the capillary system. Murine cardiac veins consist of several principal branches (with large diameters), the distal parts of which are located in the subepicardium. We have described the major branches of the left atrial veins, the vein of the left ventricle, the caudal veins, the vein of the right ventricle and the conal veins forming the conal venous circle or the prepulmonary conal venous arch running around the conus of the right ventricle. The venous system of the heart drains the blood to the coronary sinus (the left cranial caval vein) to the right atrium or to the right cranial caval vein. Systemic veins such as the left cranial caval, the right cranial caval and the caudal vein open to the right atrium. Knowledge of cardiac vein location may help to elucidate abnormal vein patterns in certain genetic malformations. PMID:17553104
Age and origin of base and precious metal veins of the Coeur d'Alene mining district, Idaho
Fleck, R.J.; Criss, R.E.; Eaton, G.F.; Cleland, R.W.; Wavra, C.S.; Bond, W.D.
2002-01-01
Ore-bearing quartz-carbonate veins of the Coeur d'Alene mining district yield 87Sr/86Sr ratios of 0.74 to >1.60 for low Rb/Sr, carbonate gangue minerals, similar to current ranges measured in Middle Proterozoic, high Rb/Sr rocks of the Belt Supergroup. Stable isotope and fluid inclusion studies establish a genetic relationship between vein formation and metamorphic-hydrothermal systems of the region. These extraordinary 87Sr/86Sr ratios require accumulation of radiogenic 87Sr in a high Rb/Sr system over an extended period prior to incorporation of Sr into the hydrothermal veins. Evaluation of the age and composition of potential sources of highly radiogenic Sr indicates that the ore-bearing veins of the Coeur d'Alene district formed during the Cretaceous from components scavenged from rocks of the Belt Supergroup, the primary host rocks of the district. Proterozoic Pb isotope ratios observed in galena from many Coeur d'Alene veins were established when Pb separated from uranium during deposition or diagenesis of the Belt Supergroup at 1400 to 1500 Ma, possibly as disseminated syngenetic deposits. K-Ar and Rb-Sr apparent ages and ??18O values of Belt Supergroup rocks decrease from the Coeur d'Alene district toward the Idaho and Kaniksu batholiths, approximately normal to the trends of metamorphic isograds, fold axes, foliation, and the major reverse faults of the district. Isoclinal folding, thrust faulting, high-temperature metamorphism, granitic plutonism, and regional-scale metamorphic-hydrothermal activity is documented in the region between 140 and 45 Ma, representing the only such combination of events in the Coeur d'Alene region subsequent to about 1300 Ma. The Sr and oxygen results and geologic evidence favor formation of the ore-bearing carbonate veins by fluids related to a complex metamorphic-hydrothermal system during the Cretaceous. Pb with Proterozoic isotopic compositions was probably mobilized and incorporated like other metals into the hydrothermal veins during this event. The ore-bearing veins were sheared and displaced during early Tertiary northwest-trending dextral strike-slip faulting along the Osburn fault and related structures of the Lewis and Clark line.
Sohrab, Sayed Sartaj; Daur, Ihsanullah
2018-02-01
Mentha is a very important crop grown and used extensively for many purposes in the Kingdom of Saudi Arabia. Begomoviruses are whitefly-transmitted viruses causing serious disease in many important plants exhibiting variable symptoms with significant economic loss globally. During farmers' field survey, yellow vein mosaic disease was observed in Mentha longifolia plants growing near tomato fields in Saudi Arabia. The causative agent was identified in 11 out of 19 samples using begomovirus-specific primers and the association of begomovirus with yellow vein mosaic disease in M. longifolia was confirmed. The full-length viral genome and betasatellite were amplified, cloned, and sequenced bidirectionally. The full DNA-A genome was found to have 2785 nucleotides with 1365 bp-associated betasatellite molecule. An attempt was made to amplify DNA-B, but none of the samples produced any positive amplicon of expected size which indicated the presence of monopartite begomovirus. The sequence identity matrix and phylogenetic analysis, based on full genome showed the highest identity (99.6%) with Tomato yellow leaf curl virus (TYLCV) and in phylogenetic analysis it formed a closed cluster with Tomato leaf curl virus infecting tomato and Corchorus crop in Saudi Arabia. The sequence analysis results of betasatellites showed the highest identity (98.9%) with Tomato yellow leaf curl betasatellites infecting tomato and phylogenetic analysis using betasatellites formed a close cluster with Tomato yellow leaf curl betasatellites infecting tomato and Corchorus crops, which has already been reported to cause yellow vein mosaic and leaf curl disease in many cultivated and weed crops growing in Saudi Arabia. The identified begomovirus associated with yellow vein mosaic disease in mentha could be a mutated strain of TYLCV and tentatively designated as TYLCV-Mentha isolate. Based on published data and latest information, this is the first report of identification of Tomato yellow leaf curl virus associated with yellow vein mosaic disease of M. longifolia from Saudi Arabia.
Pavlović, Miloš D; Schuller-Petrović, Sanja; Pichot, Olivier; Rabe, Eberhard; Maurins, Uldis; Morrison, Nick; Pannier, Felizitas
2015-05-01
Endovenous thermal ablation (ETA) procedures are catheter-directed, ultrasound (US)-guided thermal methods for treatment in varicose veins disease. Radiofrequency, laser or steam energy thermally denatures vein wall collagen, leading first to vein wall inflammation, then fibrosis and finally to occlusion. The aim of this guideline is to give evidence-based recommendations for ETA procedures. These guidelines were drafted during a consensus meeting of a group of experts in the field of ETA in June 2012 (Hvar, Croatia) under the auspices of the International Union of Phlebology (IUP). These guidelines review the present state of knowledge as reflected in peer-reviewed published medical literature. The recommendations of these guidelines are graded according to the American College of Chest Physicians Task Force recommendations on Grading Strength of Recommendations and Quality of Evidence in Clinical Guidelines. Recommendations on the use of ETA procedures were made based on the quality of evidence for efficacy, safety, tolerability, cosmetic outcome, patient satisfaction/preference and, where appropriate, on the experts' opinion. Health economics were not considered, since differences in national health systems and pricing make it difficult to form general conclusions that are relevant at an international level. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Foley, Nora K.; Ayuso, Robert A.
1994-01-01
Pb isotope compositions from the late stage of the North Amethyst vein system and from the Bondholder and central and southern Creede mining districts are more radiogenic than the host volcanic rocks of the central cluster of the San Juan volcanic field. Our Pb isotope results indicate that early Au mineralization of the North Amethyst area may represent the product of an older and relatively local hydrothermal system distinct from that of the younger base metal and Ag mineralization found throughout the region. Fluids that deposited Au minerals may have derived their Pb isotope composition by a greater degree of interaction with shallow, relatively less radiogenic volcanic wall rocks. The younger, base metal and Ag-rich mineralization that overprints the Au mineralization in the North Amethyst area clearly has a more radiogenic isotopic signature, which implies that the later mineralization derived a greater component of its Pb from Proterozoic source rocks, or sediments derived from them.Paragenetically early sulfide-rich vein assemblages have the least radiogenic galenas and generally also have the highest Au contents. Thus, identification of paragenetically early vein assemblages with relatively unradiogenic Pb isotope compositions similar to those of the North Amethyst area provides an additional exploration tool for Au in the central San Juan Mountains area.
Prevalence and characteristics of femoral injection among Seattle-area injection drug users.
Coffin, Phillip O; Coffin, Lara S; Murphy, Shilo; Jenkins, Lindsay M; Golden, Matthew R
2012-04-01
Injection drug use (IDU) into central veins, most common among long-term IDUs with no other options, can lead to severe infectious, vascular, and traumatic medical consequences. To follow-up on anecdotal reports of femoral vein injection and related medical problems in Seattle, we analyzed data from the annual survey of a community-based syringe exchange program. A total of 276 (81%) of 343 program attendees completed the survey in August 2010. Among 248 IDUs, 66% were male, 78% white, and 86% primarily injected opiates. One hundred respondents (40%) had injected into the femoral vein, 55% of whom were actively doing so, and 58% of whom reported medical complications that they attributed to the practice. Most (66%) used the femoral vein due to difficulty accessing other veins, although 61% reported other veins they could access and 67% reporting using other sites since initiating femoral injection. While injecting into muscle was more frequent among older IDUs with longer injection careers, the prevalence of femoral injection was highest among respondents in their late twenties with 2.5-6 years of injecting drugs. Multivariate analysis demonstrated an increased risk of initiating femoral injection each calendar year after 2007. Injecting into the femoral vein was also associated with white versus other race (odds ratio [OR] 2.7, 95% CI 1.3-5.4) and injection of primarily opiates versus other drugs (OR 6.3, 95% CI 1.2-32.9) and not associated with age, length of IDU career, or a history of injecting into muscle. These findings suggest a secular trend of increasing femoral injection among Seattle-area IDUs with a high rate of related medical problems. Interventions, such as education regarding the hazards of central venous injection and guidance on safe injection into peripheral veins, are needed to minimize the health consequences of femoral injection.
Vascular Structures of the Right Colon: Incidence and Variations with Their Clinical Implications.
Alsabilah, J; Kim, W R; Kim, N K
2017-06-01
There is a demand for a better understanding of the vascular structures around the right colonic area. Although right hemicolectomy with the recent concept of meticulous lymph node dissection is a standardized procedure for malignant diseases among most surgeons, variations in the actual anatomical vascular are not well understood. The aim of the present review was to present a detailed overview of the vascular variation pertinent to the surgery for right colon cancer. Medical literature was searched for the articles highlighting the vascular variation relevant to the right colon cancer surgery. Recently, there have been many detailed studies on applied surgical vascular anatomy based on cadaveric dissections, as well as radiological and intraoperative examinations to overcome misconceptions concerning the arterial supply and venous drainage to the right colon. Ileocolic artery and middle colic artery are consistently present in all patients arising from the superior mesenteric artery. Even though the ileocolic artery passes posterior to the superior mesenteric vein in most of the cases, in some cases courses anterior to the superior mesenteric artery. The right colic artery is inconsistently present ranging from 63% to 10% across different studies. Ileocolic vein and middle colic vein is always present, while the right colic vein is absent in 50% of patients. The gastrocolic trunk of Henle is present in 46%-100% patients across many studies with variation in the tributaries ranging from bipodal to tetrapodal. Commonly, it is found that the right colonic veins, including the right colic vein, middle colic vein, and superior right colic vein, share the confluence forming the gastrocolic trunk of Henle in a highly variable frequency and different forms. Understanding the incidence and variations of the vascular anatomy of right side colon is of crucial importance. Failure to recognize the variation during surgery can result in troublesome bleeding especially during minimal invasive surgery.
Crisóstomo, R S S; Candeias, M S; Armada-da-Silva, P A S
2017-03-01
To evaluate the effect of manual lymphatic drainage (MLD) on venous flow when applied to the medial and lateral aspects of the thigh and leg in patients with chronic venous insufficiency (CVI) and healthy subjects. Cross-sectional study. Participants were assessed in a school-based health community attendant service. Fifty-seven subjects participated in this study {mean age: 43 [standard deviation (SD) 14] years, 38 women and 19 men}. Of these, 28 subjects had CVI [mean age 47 (SD 12) years] and 29 subjects did not have CVI [mean age 39 (14) years]. MLD was applied by a certificated physical therapist to the medial and lateral aspects of the thigh and leg. Cross-sectional area; blood flow velocities in the femoral vein, great saphenous vein, popliteal vein and small saphenous vein at baseline and during MLD, measured by duplex ultrasound. Flow volume in the femoral vein increased from baseline [5.19 (SD 3.25)cm 3 /second] when MLD was applied to the medial [7.03 (SD 3.65)cm 3 /second; P≤0.001; mean difference -1.69; 95% confidence interval (CI) -2.42 to -0.97] and lateral [6.16 (SD 3.35)cm 3 /second; P≤0.001; mean difference -1.04; 95% CI -1.70 to -0.39] aspects of the thigh. Venous flow augmentation in the femoral vein and great saphenous vein was higher when MLD was applied to the medial aspect of the thigh (P<0.001), while MLD had a similar effect on venous blood flow regardless of whether it was applied to the medial or the lateral aspect of the leg (P=0.731). MLD increases blood flow in deep and superficial veins. MLD should be applied along the route of the venous vessels for improved venous return. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Prevalence and associations of retinal vein occlusions: the Central India Eye and Medical Study.
Jonas, Jost B; Nangia, Vinay; Khare, Anshu; Sinha, Ajit; Lambat, Sarang
2013-01-01
To determine the prevalence of retinal vein occlusions (RVOs) in rural central India. The population-based Central India Eye and Medical Study was performed in rural central India and included 4,711 subjects (30 years and older). Using fundus photographs, we assessed the prevalence of branch retinal vein occlusions and central retinal vein occlusions. An RVO was detected in 38 eyes (0.42 ± 0.07%; 95% confidence interval: 0.29-0.56) of 35 subjects (0.76 ± 0.13%; 95% confidence interval: 0.50-1.01). Prevalence of branch retinal vein occlusions was 0.66% ± 0.12% per subject (95% confidence interval: 0.42%-0.90%) and of central retinal vein occlusions was 0.11% ± 0.05% per subject (95% confidence interval: 0.01%-0.21%). In binary logistic analysis, presence of RVOs was associated with higher age (P = 0.007), systolic blood pressure (P < 0.001), blood concentration of urea (P = 0.02), and narrower anterior chamber angle (P < 0.03). The RVO prevalence was not significantly (all Ps > 0.10) associated with body mass index; blood concentrations of glucose, cholesterol, high-density lipoproteins, and creatinine; presence of diabetes mellitus, tuberculosis and malaria; nutritional parameters; alcohol consumption; refractive error; and optic disk size. The age-specific prevalence rates of RVOs were 0.18% ± 0.13%, 0.29% ± 0.15%, 0.89% ± 0.34%, 1.07% ± 0.36%, 2.72% ± 0.85%, and 3.64% ± 2.55%, respectively, for decadal age groups. In two (5%) eyes, RVO had caused low vision (visual acuity <20/60 and ≥20/400). In the rural agrarian low-income population of Central India, RVOs were detected in 0.8% of adults, with branch retinal vein occlusions being approximately seven times more common than central retinal vein occlusions. Main associated factors were higher age, blood pressure, urea blood concentration, and narrow chamber angle. RVOs were no major reason for visual impairment.
Three-dimensional vasculature of the bovine liver.
Shirai, W; Sato, T; Shibuya, H; Naito, K; Tsukise, A
2005-12-01
To clarify anatomical distribution of Fasciola infection, the vascular and ductal architectures of the liver were studied by means of corrosion cast technique using synthetic resin. The arteria hepatica propria (AP) passes as the arteria gastroduodenalis (AG); AP becomes the left trunk after the porta hepatis; AP passes on the right side of vena porta communis (VPC) and projects AG while curving in a U-shape below the portal vein. Hepatic veins located between the vena hepatica media (HM) and vena hepatica dextra (HD) varied widely among specimens and were irregular, including the vena hepatica dorso-lateralis sinistra (Hds), vena hepatica dorso-lateralis dextra (Hdd), vena hepatica lobi caudati (Hlc), venae hepaticae processus caudati (Hpc), venae hepaticae processus papillaris (Hpp), and the hepatic vein to the dorsal intermediate part, which directly or indirectly drained into the vena cava caudalis. The courses of the bovine hepatic veins were markedly diverse, and anastomoses between vena hepatica sinistra (HS) and Hds were observed in about a half of the livers. The portal vein entered the liver as VPC slightly above the centre of the right lobe on the visceral surface. The intermediate or transverse part [pars transversa trunci sinistri (PTS)] of truncus sinister (TS), which extends from the entry of the portal vein into the left lobe of the liver, was slightly arched downward [pars umbilicalis trunci sinistri (PUS)]. The portal vein further arched from the distal end of TS to the umbilical vein and ran towards the inter-lobar incision between the left lobe and quadrate lobe. Based on these branches, hepatic segments were determined as 13 or 14 areas. A total of 15 bile ducts were derived from various lobes. The hepatic duct was about 2.6-6 cm long from the confluence of the right and left hepatic ducts to the division of the cystic duct and the common hepatic duct.
NASA Astrophysics Data System (ADS)
Kuşcu, Mustafa; Cengiz, Oya; Işık, Kayhan; Gül, E. Kübra
2018-07-01
Rutile occur in important amounts within Quaternary detrital sediments, and quartz veins which cut down the Paleozoic aged Eşme formation in the Menderes Massif on the Neoproterozoic Pan-Afrikan Belt in the west of Turkey. As a result of erosion, transport and accumulation of rutile-bearing quartz veins in the mica schists of the Eşme formation outcropped between Eşme (Uşak) and Kula (Manisa), the placer rutile occurrences occur in terraces, fluvial-alluvial and eluvial deposits. This study investigates the element content of rutile, oxygen isotope ratios of rutile and quartz, and formation temperature of rutile related to titanium source rock. Field observations show that rutiles are located in quartz veins that cut the schists. After these veins were fragmented and eroded, blocks of quartz with rutile and rutile grains are transported into clastic sediments in slope debris (eluvial), terraces and recent fluvial-alluvial deposits. Whereas quartz, rutile, ilmenite, and albite are found in the paragenesis of the rutile-bearing quartz vein fragments, the placers forming the terraces and current fluvial-alluvial deposits contain quartz, albite, muscovite, orthoclase, kaolinite, rutile, dravite, ilmenite, and zircon. The rutile grains in the examined placers and quartz vein fragments have grain sizes ranging from mm fractions to 5-6 cm. The major oxide compositions of the rutile grains have average values of 94 wt.% TiO2, 1.5 wt.% Fe2O3, 0.5 wt.% SiO2, and 0.3 wt.% Al2O3. The rutile samples have average values Nb of 1424 ppm, V of 980 ppm, W of 192 ppm, Ta of 94 ppm, and Zr of 73 ppm. The rutiles in the study area are defined as iron-rich rutile "nigrine" due to high iron content. Quartz veins are host rocks of rutile grains in the terrace and fluvial-aluvial sediments. The rutile-bearing quartz veins may be sourced from the Lower-Middle Miocene aged granites which are intruded the rocks in the Menderes Massif. Based on the analysis results of the methods of Zr thermometer from Zr values containing rutile and quartz-rutile geothermometer from oxygen isotope results (13.5‰ and 6‰) of quartz and rutile samples, the formation temperature of the rutile-bearing quartz veins were found to be at temperatures of 537 °C and 561 °C, respectively. These temperatures indicate that the rutile-bearing quartz veins may be in a temperature range between pegmatitic and/or hydrothermal stages.
Bimodal Biometric Verification Using the Fusion of Palmprint and Infrared Palm-Dorsum Vein Images
Lin, Chih-Lung; Wang, Shih-Hung; Cheng, Hsu-Yung; Fan, Kuo-Chin; Hsu, Wei-Lieh; Lai, Chin-Rong
2015-01-01
In this paper, we present a reliable and robust biometric verification method based on bimodal physiological characteristics of palms, including the palmprint and palm-dorsum vein patterns. The proposed method consists of five steps: (1) automatically aligning and cropping the same region of interest from different palm or palm-dorsum images; (2) applying the digital wavelet transform and inverse wavelet transform to fuse palmprint and vein pattern images; (3) extracting the line-like features (LLFs) from the fused image; (4) obtaining multiresolution representations of the LLFs by using a multiresolution filter; and (5) using a support vector machine to verify the multiresolution representations of the LLFs. The proposed method possesses four advantages: first, both modal images are captured in peg-free scenarios to improve the user-friendliness of the verification device. Second, palmprint and vein pattern images are captured using a low-resolution digital scanner and infrared (IR) camera. The use of low-resolution images results in a smaller database. In addition, the vein pattern images are captured through the invisible IR spectrum, which improves antispoofing. Third, since the physiological characteristics of palmprint and vein pattern images are different, a hybrid fusing rule can be introduced to fuse the decomposition coefficients of different bands. The proposed method fuses decomposition coefficients at different decomposed levels, with different image sizes, captured from different sensor devices. Finally, the proposed method operates automatically and hence no parameters need to be set manually. Three thousand palmprint images and 3000 vein pattern images were collected from 100 volunteers to verify the validity of the proposed method. The results show a false rejection rate of 1.20% and a false acceptance rate of 1.56%. It demonstrates the validity and excellent performance of our proposed method comparing to other methods. PMID:26703596
NASA Astrophysics Data System (ADS)
Apukhtina, Olga B.; Kamenetsky, Vadim S.; Ehrig, Kathy; Kamenetsky, Maya B.; McPhie, Jocelyn; Maas, Roland; Meffre, Sebastien; Goemann, Karsten; Rodemann, Thomas; Cook, Nigel J.; Ciobanu, Cristiana L.
2016-01-01
An assemblage of magnetite and apatite is common worldwide in different ore deposit types, including disparate members of the iron-oxide copper-gold (IOCG) clan. The Kiruna-type iron oxide-apatite deposits, a subtype of the IOCG family, are recognized as economic targets as well. A wide range of competing genetic models exists for magnetite-apatite deposits, including magmatic, magmatic-hydrothermal, hydrothermal(-metasomatic), and sedimentary(-exhalative). The sources and mechanisms of transport and deposition of Fe and P remain highly debatable. This study reports petrographic and geochemical features of the magnetite-apatite-rich vein assemblages in the dolerite dykes of the Gairdner Dyke Swarm (~0.82 Ga) that intruded the Roxby Downs Granite (~0.59 Ga), the host of the supergiant Olympic Dam IOCG deposit. These symmetrical, only few mm narrow veins are prevalent in such dykes and comprise besides usually colloform magnetite and prismatic apatite also further minerals (e.g., calcite, quartz). The genetic relationships between the veins and host dolerite are implied based on alteration in the immediate vicinity (~4 mm) of the veins. In particular, Ti-magnetite-ilmenite is partially to completely transformed to titanite and magmatic apatite disappears. We conclude that the mafic dykes were a local source of Fe and P re-concentrated in the magnetite-apatite veins. Uranium-Pb ages for vein apatite and titanite associated with the vein in this case study suggest that alteration of the dolerite and healing of the fractures occurred shortly after dyke emplacement. We propose that in this particular case the origin of the magnetite-apatite assemblage is clearly related to hydrothermal alteration of the host mafic magmatic rocks.
Impaired Left Ventricular Filling in COPD and Emphysema: Is It the Heart or the Lungs?
Smith, Benjamin M.; Prince, Martin R.; Hoffman, Eric A.; Bluemke, David A.; Liu, Chia-Ying; Rabinowitz, Dan; Hueper, Katja; Parikh, Megha A.; Gomes, Antoinette S.; Michos, Erin D.; Lima, João A. C.; Barr, R. Graham
2013-01-01
Background: COPD and heart failure with preserved ejection fraction overlap clinically, and impaired left ventricular (LV) filling is commonly reported in COPD. The mechanism underlying these observations is uncertain, but may include upstream pulmonary dysfunction causing low LV preload or intrinsic LV dysfunction causing high LV preload. The objective of this study is to determine if COPD and emphysema are associated with reduced pulmonary vein dimensions suggestive of low LV preload. Methods: The population-based Multi-Ethnic Study of Atherosclerosis (MESA) COPD Study recruited smokers aged 50 to 79 years who were free of clinical cardiovascular disease. COPD was defined by spirometry. Percent emphysema was defined as regions < −910 Hounsfield units on full-lung CT scan. Ostial pulmonary vein cross-sectional area was measured by contrast-enhanced cardiac magnetic resonance and expressed as the sum of all pulmonary vein areas. Linear regression was used to adjust for age, sex, race/ethnicity, body size, and smoking. Results: Among 165 participants, the mean (± SD) total pulmonary vein area was 558 ± 159 mm2 in patients with COPD and 623 ± 145 mm2 in control subjects. Total pulmonary vein area was smaller in patients with COPD (−57 mm2; 95% CI, −106 to −7 mm2; P = .03) and inversely associated with percent emphysema (P < .001) in fully adjusted models. Significant decrements in total pulmonary vein area were observed among participants with COPD alone, COPD with emphysema on CT scan, and emphysema without spirometrically defined COPD. Conclusions: Pulmonary vein dimensions were reduced in COPD and emphysema. These findings support a mechanism of upstream pulmonary causes of underfilling of the LV in COPD and in patients with emphysema on CT scan. PMID:23764937
Bimodal Biometric Verification Using the Fusion of Palmprint and Infrared Palm-Dorsum Vein Images.
Lin, Chih-Lung; Wang, Shih-Hung; Cheng, Hsu-Yung; Fan, Kuo-Chin; Hsu, Wei-Lieh; Lai, Chin-Rong
2015-12-12
In this paper, we present a reliable and robust biometric verification method based on bimodal physiological characteristics of palms, including the palmprint and palm-dorsum vein patterns. The proposed method consists of five steps: (1) automatically aligning and cropping the same region of interest from different palm or palm-dorsum images; (2) applying the digital wavelet transform and inverse wavelet transform to fuse palmprint and vein pattern images; (3) extracting the line-like features (LLFs) from the fused image; (4) obtaining multiresolution representations of the LLFs by using a multiresolution filter; and (5) using a support vector machine to verify the multiresolution representations of the LLFs. The proposed method possesses four advantages: first, both modal images are captured in peg-free scenarios to improve the user-friendliness of the verification device. Second, palmprint and vein pattern images are captured using a low-resolution digital scanner and infrared (IR) camera. The use of low-resolution images results in a smaller database. In addition, the vein pattern images are captured through the invisible IR spectrum, which improves antispoofing. Third, since the physiological characteristics of palmprint and vein pattern images are different, a hybrid fusing rule can be introduced to fuse the decomposition coefficients of different bands. The proposed method fuses decomposition coefficients at different decomposed levels, with different image sizes, captured from different sensor devices. Finally, the proposed method operates automatically and hence no parameters need to be set manually. Three thousand palmprint images and 3000 vein pattern images were collected from 100 volunteers to verify the validity of the proposed method. The results show a false rejection rate of 1.20% and a false acceptance rate of 1.56%. It demonstrates the validity and excellent performance of our proposed method comparing to other methods.
NASA Astrophysics Data System (ADS)
Chang, Ya-Ju; Huang, Hui-Chun; Hsueh, Yuan-Yu; Wang, Shao-Wei; Su, Fong-Chin; Chang, Chih-Han; Tang, Ming-Jer; Li, Yi-Shuan; Wang, Shyh-Hau; Shung, Kirk K.; Chien, Shu; Wu, Chia-Ching
2016-02-01
Little is known regarding the interplays between the mechanical and molecular bases for vein graft restenosis. We elucidated the stenosis initiation using a high-frequency ultrasonic (HFU) echogenicity platform and estimated the endothelium yield stress from von-Mises stress computation to predict the damage locations in living rats over time. The venous-arterial transition induced the molecular cascades for autophagy and apoptosis in venous endothelial cells (ECs) to cause neointimal hyperplasia, which correlated with the high echogenicity in HFU images and the large mechanical stress that exceeded the yield strength. The ex vivo perfusion of arterial laminar shear stress to isolated veins further confirmed the correlation. EC damage can be rescued by inhibiting autophagy formation using 3-methyladenine (3-MA). Pretreatment of veins with 3-MA prior to grafting reduced the pathological increases of echogenicity and neointima formation in rats. Therefore, this platform provides non-invasive temporal spatial measurement and prediction of restenosis after venous-arterial transition as well as monitoring the progression of the treatments.
Multisensory System for the Detection and Localization of Peripheral Subcutaneous Veins
Fernández, Roemi; Armada, Manuel
2017-01-01
This paper proposes a multisensory system for the detection and localization of peripheral subcutaneous veins, as a first step for achieving automatic robotic insertion of catheters in the near future. The multisensory system is based on the combination of a SWIR (Short-Wave Infrared) camera, a TOF (Time-Of-Flight) camera and a NIR (Near Infrared) lighting source. The associated algorithm consists of two main parts: one devoted to the features extraction from the SWIR image, and another envisaged for the registration of the range data provided by the TOF camera, with the SWIR image and the results of the peripheral veins detection. In this way, the detected subcutaneous veins are mapped onto the 3D reconstructed surface, providing a full representation of the region of interest for the automatic catheter insertion. Several experimental tests were carried out in order to evaluate the capabilities of the presented approach. Preliminary results demonstrate the feasibility of the proposed design and highlight the potential benefits of the solution. PMID:28422075
Gasston, Erin; Mauk, Jeffrey L.; Cosca, Michael A.; Morgan, Leah; Hall, Chris M.
2017-01-01
The world-class Waihi vein system in New Zealand has produced more than 248,400 kg Au and 1.43 million kg Ag. New high-precision 40Ar/39Ar dates of adularia from different veins show that some veins formed at different times (6.15 Ma Martha vs. 5.83 and 5.85 Ma Empire and Welcome, respectively), even though they have similar mineralogy. The Martha vein formed over a period of approximately 150,000 years. The Moonlight vein, which has a different ore mineral assemblage, appears to have formed over a longer time interval that spanned formation of the Martha, Welcome, and Empire veins. These dates suggest that some veins in the Waihi vein system formed relatively quickly during only part of the lifetime of the hydrothermal system, whereas other veins may have formed over longer periods of time. However, the Au endowment of the Martha vein exceeds the Au endowment of the Moonlight vein, indicating that the total lifetime of the vein-forming hydrothermal system does not determine metal endowment.
NASA Astrophysics Data System (ADS)
Kato, Yukako; Sekine, Toshimori; Kayama, Masahiko; Miyahara, Masaaki; Yamaguchi, Akira
2017-12-01
Shock pressure recorded in Yamato (Y)-790729, classified as L6 type ordinary chondrite, was evaluated based on high-pressure polymorph assemblages and cathodoluminescence (CL) spectra of maskelynite. The host-rock of Y-790729 consists mainly of olivine, low-Ca pyroxene, plagioclase, metallic Fe-Ni, and iron-sulfide with minor amounts of phosphate and chromite. A shock-melt vein was observed in the hostrock. Ringwoodite, majorite, akimotoite, lingunite, tuite, and xieite occurred in and around the shock-melt vein. The shock pressure in the shock-melt vein is about 14-23 GPa based on the phase equilibrium diagrams of high-pressure polymorphs. Some plagioclase portions in the host-rock occurred as maskelynite. Sixteen different CL spectra of maskelynite portions were deconvolved using three assigned emission components (centered at 2.95, 3.26, and 3.88 eV). The intensity of emission component at 2.95 eV was selected as a calibrated barometer to estimate shock pressure, and the results indicate pressures of about 11-19 GPa. The difference in pressure between the shock-melt vein and host-rock might suggest heterogeneous shock conditions. Assuming an average shock pressure of 18 GPa, the impact velocity of the parent-body of Y-790729 is calculated to be 1.90 km s-1. The parent-body would be at least 10 km in size based on the incoherent formation mechanism of ringwoodite in Y-790729.
Onishi, S; Imanishi, N; Yoshimura, Y; Inoue, Y; Sakamoto, Y; Chang, H; Okumoto, T
2017-04-01
The venous anatomy of the face was examined in 12 fresh cadavers. Venograms and arteriovenograms were obtained after the injection of contrast medium. In 8 of the 12 cadavers, a large loop was formed by the facial vein, the supratrochlear vein, and the superficial temporal vein, which became the main trunk vein of the face. In 4 of the 12 cadavers, the superior lateral limb of the loop vein was less well developed. The loop vein generally did not accompany the arteries of the face. Cutaneous branches of the loop vein formed a polygonal venous network in the skin, while communicating branches ran toward deep veins. These findings suggest that blood from the dermis of the face is collected by the polygonal venous network and enters the loop vein through the cutaneous branches, after which blood flows away from the face through the superficial temporal vein, the facial vein, and the communicating branches and enters the deep veins. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Manning, C. E.; Kelemen, P. B.; Michibayashi, K.; Harris, M.; Urai, J. L.; de Obeso, J. C.; Jesus, A. P. M.; Zeko, D.
2017-12-01
Oman Drilling Project Hole BT1B intersected 191 m of listvenite (magnesite + quartz rock) and serpentinite in the hanging wall of the basal thrust of the Oman ophiolite. Recovery was 100%. Listvenite is the dominant lithology in the upper plate rocks (166 m). Its shows wide color and textural variation, including pseudomorphic replacement of serpentinized peridotite. Serpentinite was encountered in two main contiguous intervals totaling 25 m. In light of the strongly metasomatic nature for the origin of listvenite, a substantial portion of the core description effort was dedicated to characterization of the complex veining history recorded in the hole. Dense veining is recorded in both lithologies. The density of <1 mm veins is >200/m. The density of veins >1 mm was 50-100/m, with somewhat higher densities recorded in serpentinite than in listvenite. In order of oldest to youngest, the main vein types in serpentinite are microscopic mesh-textured serpentine veins, macroscopic serpentine veins, carbonate-oxide veins, and carbonate veins. The vein paragenesis in listvenite is: early carbonate-oxide veins, followed by carbonate and carbonate-quartz veins, then late carbonate veins. The carbonate-oxide and carbonate veins are shared by the lithologies and hold clues to the transformation of ultramafic rocks to listvenite. Carbonate-oxide veins form a distinctive set that is interpreted to be the earliest record of carbonate formation in serpentinite. They contain Fe-oxide, usually hematite, on a medial line, with antitaxial magnesite crystals growing outward and showing terminations against wall rock minerals. Antitaxial textures may be evidence of positive reaction volumes. In serpentinite, secondary serpentine after earlier serpentine is common at vein margins. Carbonate-oxide veins are the earliest observed in listvenite, where they may form isolated veins to dense, aligned networks that impart a foliated texture. In some cases, they appear to predate replacement of serpentine by microcrystalline quartz. Both lithologies record later, coarser, through going carbonate ± quartz veins. Preliminary vein petrology in BT1B rocks indicates that fracture formation and filling by secondary minerals is integral to the metasomatic replacement of altered peridotite by listvenite.
NASA Astrophysics Data System (ADS)
Catchpole, Honza; Kouzmanov, Kalin; Bendezú, Aldo; Ovtcharova, Maria; Spikings, Richard; Stein, Holly; Fontboté, Lluís
2015-12-01
The Morococha district in central Peru is characterised by economically important Cordilleran polymetallic (Zn-Pb-Ag-Cu) vein and replacement bodies and the large Toromocho porphyry Cu-Mo deposit in its centre. U-Pb, Re-Os, and 40Ar/39Ar geochronology data for various porphyry-related hydrothermal mineralisation styles record a 3.5-Ma multi-stage history of magmatic-hydrothermal activity in the district. In the late Miocene, three individual magmatic-hydrothermal centres were active: the Codiciada, Toromocho, and Ticlio centres, each separated in time and space. The Codiciada centre is the oldest magmatic-hydrothermal system in the district and consists of a composite porphyry stock associated with anhydrous skarn and quartz-molybdenite veins. The hydrothermal events are recorded by a titanite U-Pb age at 9.3 ± 0.2 Ma and a molybdenite Re-Os age at 9.26 ± 0.03 Ma. These ages are indistinguishable from zircon U-Pb ages for porphyry intrusions of the composite stock and indicate a time span of 0.2 Ma for magmatic-hydrothermal activity. The small Ticlio magmatic-hydrothermal centre in the west of the district has a maximum duration of 0.3 Ma, ranging from porphyry emplacement to porphyry mineralisation at 8.04 ± 0.14 Ma (40Ar/39Ar muscovite cooling age). The Toromocho magmatic-hydrothermal centre has a minimum of five recorded porphyry intrusions that span a total of 1.3 Ma and is responsible for the formation of the giant Toromocho Cu-Mo deposit. At least two hydrothermal pulses are identified. Post-dating a first pulse of molybdenite mineralisation, wide-spread hydrous skarn covers an area of over 6 km2 and is recorded by five 40Ar/39Ar cooling ages at 7.2-6.8 Ma. These ages mark the end of the slowly cooling and long-lived Toromocho magmatic-hydrothermal centre soon after last magmatic activity at 7.26 ± 0.02 Ma. District-wide (50 km2) Cordilleran base metal vein and replacement bodies post-date the youngest recorded porphyry mineralisation event at Toromocho by more than 0.5 Ma. Polymetallic veins (5.78 ± 0.10 and 5.72 ± 0.18 Ma; 40Ar/39Ar ages) and the Manto Italia polymetallic replacement bodies (6.23 ± 0.12 and 6.0 ± 0.2 Ma; 40Ar/39Ar ages) are interpreted to have been formed by a single hydrothermal pulse. Hydrothermal activity ceased after the formation of the base metal vein and replacement bodies. Overlapping monazite U-Pb (8.26 ± 0.18 Ma) and muscovite 40Ar/39Ar ages (8.1 ± 0.5 Ma) from the early base metal stage of one Cordilleran vein sample in the Sulfurosa area provide evidence that a discrete hydrothermal pulse was responsible for polymetallic vein formation 2.6 Ma prior to the district-wide polymetallic veins. These ages pre-date those of Toromocho porphyry Cu-Mo formation and show that Zn-Pb-Ag-Cu mineralisation formed during several discrete magmatic-hydrothermal pulses in the same district.
Holdstock, J M; Dos Santos, S J; Harrison, C C; Price, B A; Whiteley, M S
2015-03-01
To determine the prevalence of haemorrhoids in women with pelvic vein reflux, identify which pelvic veins are associated with haemorrhoids and assess if extent of pelvic vein reflux influences the prevalence of haemorrhoids. Females presenting with leg varicose veins undergo duplex ultrasonography to assess all sources of venous reflux. Those with significant reflux arising from the pelvis are offered transvaginal duplex ultrasound (TVS) to evaluate reflux in the ovarian veins and internal Iliac veins and associated pelvic varices in the adnexa, vulvar/labial veins and haemorrhoids. Patterns and severity of reflux were evaluated. Between January 2010 and December 2012, 419 female patients with leg or vulvar varicose vein patterns arising from the pelvis underwent TVS. Haemorrhoids were identified on TVS via direct tributaries from the internal Iliac veins in 152/419 patients (36.3%) and absent in 267/419 (63.7%). The prevalence of the condition increased with the number of pelvic trunks involved. There is a strong association between haemorrhoids and internal Iliac vein reflux. Untreated reflux may be a cause of subsequent symptomatic haemorrhoids. Treatment with methods proven to work in conditions caused by pelvic vein incompetence, such as pelvic vein embolisation and foam sclerotherapy, could be considered. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Safety of Venipuncture Sites at the Cubital Fossa as Assessed by Ultrasonography.
Mukai, Kanae; Nakajima, Yukari; Nakano, Tomotaka; Okuhira, Manami; Kasashima, Aya; Hayashi, Rina; Yamashita, Misaki; Urai, Tamae; Nakatani, Toshio
2017-11-15
The aim of the present observational study was to identify safe and suitable venipuncture sites for nursing in the clinical setting using ultrasonography to measure the depth and cross-sectional area of each superficial vein before and after tourniquet application as well as the distance between each superficial vein and the median nerve or brachial artery. Twenty healthy volunteers (21.8 [0.6] y) were recruited. The visible rate of each superficial vein before and after tourniquet application was 65% for the basilic vein, 90% to 95% for the median cubital vein, and 65% to 80% for the cephalic vein. The cross-sectional area of the median cubital vein after tourniquet application was significantly larger than that of the basilic vein and cephalic vein. The distance between the basilic vein or median cubital vein and median nerve was significantly smaller than that between the cephalic vein and median nerve. The distance between the basilic vein or median cubital vein and brachial artery was significantly smaller than that between the cephalic vein and brachial artery. These results demonstrated that the cephalic vein at the cubital fossa is a relatively safe venipuncture site because of its distance from the median nerve and brachial artery. When puncturing the cephalic vein is difficult because it is not visible, the median cubital vein at the cubital fossa may be selected for venipuncture due to its cross-sectional area and visibility; however, care is needed to avoid penetrating the vein because the median nerve and brachial artery are located underneath.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dahlkamp, F.J.; Adams, S.S.
1981-01-01
The discovery of the Rabbit Lake deposit, Saskatchewan, in 1968 and the East Alligator Rivers district, Northern Territory, Australia, in 1970 established the Lower-Middle Proterozoic veinlike-type deposits as one of the major types of uranium deposits. The term veinlike is used in order to distinguish it from the classical magmatic-hydrothermal vein or veintype deposits. The veinlike deposits account for between a quarter and a third of the Western World's proven uranium reserves. Lower-Middle Proterozoic veinlike deposits, as discussed in this report include several subtypes of deposits, which have some significantly different geologic characteristics. These various subtypes appear to have formedmore » from various combinations of geologic processes ranging from synsedimentary uranium precipitation through some combination of diagenesis, metamorphism, metasomatism, weathering, and deep burial diagenesis. Some of the deposit subtypes are based on only one or two incompletely described examples; hence, even the classification presented in this report may be expected to change. Geologic characteristics of the deposits differ significantly between most districts and in some cases even between deposits within districts. Emphasis in this report is placed on deposit descriptions and the interpretations of the observers.« less
Enhancement of the visibility of objects located below the surface of a scattering medium
Demos, Stavros
2013-11-19
Techniques are provided for enhancing the visibility of objects located below the surface of a scattering medium such as tissue, water and smoke. Examples of such an object include a vein located below the skin, a mine located below the surface of the sea and a human in a location covered by smoke. The enhancement of the image contrast of a subsurface structure is based on the utilization of structured illumination. In the specific application of this invention to image the veins in the arm or other part of the body, the issue of how to control the intensity of the image of a metal object (such as a needle) that must be inserted into the vein is also addressed.
A biochemically semi-detailed model of auxin-mediated vein formation in plant leaves.
Roussel, Marc R; Slingerland, Martin J
2012-09-01
We present here a model intended to capture the biochemistry of vein formation in plant leaves. The model consists of three modules. Two of these modules, those describing auxin signaling and transport in plant cells, are biochemically detailed. We couple these modules to a simple model for PIN (auxin efflux carrier) protein localization based on an extracellular auxin sensor. We study the single-cell responses of this combined model in order to verify proper functioning of the modeled biochemical network. We then assemble a multicellular model from the single-cell building blocks. We find that the model can, under some conditions, generate files of polarized cells, but not true veins. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Camkiran Firat, Aynur; Zeyneloglu, Pinar; Ozkan, Murat; Pirat, Arash
2016-09-01
To compare internal jugular vein and subclavian vein access for central venous catheterization in terms of success rate and complications. A 1:1 randomized controlled trial. Baskent University Medical Center. Pediatric patients scheduled for cardiac surgery. Two hundred and eighty children undergoing central venous catheterization were randomly allocated to the internal jugular vein or subclavian vein group during a period of 18 months. The primary outcome was the first-attempt success rate of central venous catheterization through either approach. The secondary outcomes were the rates of infectious and mechanical complications. The central venous catheterization success rate at the first attempt was not significantly different between the subclavian vein (69%) and internal jugular vein (64%) groups (p = 0.448). However, the overall success rate was significantly higher through the subclavian vein (91%) than the internal jugular vein (82%) (p = 0.037). The overall frequency of mechanical complications was not significantly different between the internal jugular vein (25%) and subclavian vein (31%) (p = 0.456). However, the rate of arterial puncture was significantly higher with internal jugular vein (8% vs 2%; p = 0.03) and that of catheter malposition was significantly higher with subclavian vein (17% vs 1%; p < 0.001). The rates per 1,000 catheter days for both positive catheter-tip cultures (26.1% vs 3.6%; p < 0.001) and central-line bloodstream infection (6.9 vs 0; p < 0.001) were significantly higher with internal jugular vein. There were no significant differences between the groups in the length of ICU and hospital stays or in-hospital mortality rates (p > 0.05 for all). Central venous catheterization through the internal jugular vein and subclavian vein was not significantly different in terms of success at the first attempt. Although the types of mechanical complications were different, the overall rate was similar between internal jugular vein and subclavian vein access. The risk of infectious complications was significantly higher with internal jugular vein access.
Natural history of deep vein thrombosis in children.
Spentzouris, G; Gasparis, A; Scriven, R J; Lee, T K; Labropoulos, N
2015-07-01
To determine the natural history of deep vein thrombosis in children presented with a first episode in the lower extremity veins. Children with objective diagnosis of acute deep vein thrombosis were followed up with ultrasound and clinical examination. Risk factors and clinical presentation were prospectively collected. The prevalence of recurrent deep vein thrombosis and the development of signs and symptoms of chronic venous disease were recorded. There were 27 children, 15 males and 12 females, with acute deep vein thrombosis, with a mean age of 4 years, range 0.1-16 years. The median follow-up was 23 months, range 8-62 months. The location of thrombosis involved the iliac and common femoral vein in 18 patients and the femoral and popliteal veins in 9. Only one vein was affected in 7 children, two veins in 14 and more than two veins in 6. Recurrent deep vein thrombosis occurred in two patients, while no patient had a clinically significant pulmonary embolism. Signs and symptoms of chronic venous disease were present at last follow-up in 11 patients. There were nine patients with vein collaterals, but no patient developed varicose veins. Reflux was found in 18 veins of 11 patients. Failure of recanalization was seen in 7 patients and partial recanalization in 11. Iliofemoral thrombosis (p = 0.012) and failure to recanalize (p = 0.036) increased significantly the risk for developing signs and symptoms. Children with acute proximal deep vein thrombosis develop mild chronic venous disease signs and symptoms at mid-term follow-up and are closely related with iliofemoral thrombosis and failure to recanalization. © The Author(s) 2014.
Recognition-Based Pedagogy: Teacher Candidates' Experience of Deficit
ERIC Educational Resources Information Center
Parkison, Paul T.; DaoJensen, Thuy
2014-01-01
This study seeks to introduce what we call "recognition-based pedagogy" as a conceptual frame through which teachers and instructors can collaboratively develop educative experiences with students. Recognition-based pedagogy connects the theories of critical pedagogy, identity politics, and the politics of recognition with the educative…
Finger vein extraction using gradient normalization and principal curvature
NASA Astrophysics Data System (ADS)
Choi, Joon Hwan; Song, Wonseok; Kim, Taejeong; Lee, Seung-Rae; Kim, Hee Chan
2009-02-01
Finger vein authentication is a personal identification technology using finger vein images acquired by infrared imaging. It is one of the newest technologies in biometrics. Its main advantage over other biometrics is the low risk of forgery or theft, due to the fact that finger veins are not normally visible to others. Extracting finger vein patterns from infrared images is the most difficult part in finger vein authentication. Uneven illumination, varying tissues and bones, and changes in the physical conditions and the blood flow make the thickness and brightness of the same vein different in each acquisition. Accordingly, extracting finger veins at their accurate positions regardless of their thickness and brightness is necessary for accurate personal identification. For this purpose, we propose a new finger vein extraction method which is composed of gradient normalization, principal curvature calculation, and binarization. As local brightness variation has little effect on the curvature and as gradient normalization makes the curvature fairly uniform at vein pixels, our method effectively extracts finger vein patterns regardless of the vein thickness or brightness. In our experiment, the proposed method showed notable improvement as compared with the existing methods.
Concerns and Discomforts of Pregnancy - Varicose Veins
Concerns and Discomforts of Pregnancy - Varicose Veins Varicose veins are enlarged veins you may see on your ... Healthy Roads Media project www. healthyroadsmedia. org English - Concerns and Discomforts of Pregnancy (Varicose Veins) Last reviewed ...
Deep vein thrombosis, or DVT, is a blood clot that forms in a vein deep in the body. Most ... vein swells, the condition is called thrombophlebitis. A deep vein thrombosis can break loose and cause a serious problem ...
Pelvic Vein Embolisation in the Management of Varicose Veins
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ratnam, Lakshmi A.; Marsh, Petra; Holdstock, Judy M.
2008-11-15
Pelvic vein incompetence is common in patients with atypical varicose veins, contributing to their recurrence after surgery. Therefore, refluxing pelvic veins should be identified and treated. We present our experience with pelvic vein embolisation in patients presenting with varicose veins. Patients presenting with varicose veins with a duplex-proven contribution from perivulval veins undergo transvaginal duplex sonography (TVUS) to identify refluxing pelvic veins. Those with positive scans undergo embolisation before surgical treatment of their lower limb varicose veins. A total of 218 women (mean age of 46.3 years) were treated. Parity was documented in the first 60 patients, of whom 47more » (78.3%) were multiparous, 11 (18.3%) had had one previous pregnancy, and 2 (3.3%) were nulliparous. The left ovarian vein was embolised in 78%, the right internal iliac in 64.7%, the left internal iliac in 56.4%, and the right ovarian vein in 42.2% of patients. At follow-up TVUS, mild reflux only was seen in 16, marked persistent reflux in 6, and new reflux in 3 patients. These 9 women underwent successful repeat embolisation. Two patients experienced pulmonary embolisation of the coils, of whom 1 was asymptomatic and 1 was successfully retrieved; 1 patient had a misplaced coil protruding into the common femoral vein; and 1 patient had perineal thrombophlebitis. The results of our study showed that pelvic venous embolisation by way of a transjugular approach is a safe and effective technique in the treatment of pelvic vein reflux.« less
MDCT diagnosis of post-traumatic hepatic arterio-portal fistulas.
Nguyen, Cuong T; Nguyen, Coung; Saksobhavivat, Nitima; Saksobahavivat, Nitima; Shanmuganathan, Kathirkamanathan; Steenburg, Scott D; Steenburg, Scott; Moeslein, Fred M; Moeslein, Fred; Mirvis, Stuart E; Chiu, William
2013-06-01
The purpose of this study is to evaluate the performance of multidetector computed tomography (MDCT) in diagnosing arterioportal fistulas (APF) in high-grade liver injury. A retrospective analysis of catheter-based hepatic angiograms performed for major penetrating and blunt liver injuries identified 11 patients with APFs. Using the trauma registry, two additional demographically matched groups with and without liver injury were formed. A randomized qualitative consensus review of 33 MDCTs was performed by three trauma radiologists for the following MDCT findings of APF: transient hepatic parenchymal attenuation differences (THPAD), early increased attenuation of a peripheral or central portal vein compared with the main portal vein, and the "double-barrel" or "rail tract" signs. THPAD was the most sensitive finding and also had a high specificity for diagnosing APF. Both the early increased attenuation of a peripheral or central portal vein compared with the main portal vein and the double-barrel or rail tract signs had a100% specificity and a sensitivity of 64% and 36%, respectively. Measurement of differences in attenuation values between the APF and the contralateral central portal vein was most sensitive and specific in diagnosing APF. Traumatic APF of the liver can be optimally diagnosed with arterial phase imaging of solid organ using MDCT.
Dermatas, Evangelos
2015-01-01
A novel method for finger vein pattern extraction from infrared images is presented. This method involves four steps: preprocessing which performs local normalization of the image intensity, image enhancement, image segmentation, and finally postprocessing for image cleaning. In the image enhancement step, an image which will be both smooth and similar to the original is sought. The enhanced image is obtained by minimizing the objective function of a modified separable Mumford Shah Model. Since, this minimization procedure is computationally intensive for large images, a local application of the Mumford Shah Model in small window neighborhoods is proposed. The finger veins are located in concave nonsmooth regions and, so, in order to distinct them from the other tissue parts, all the differences between the smooth neighborhoods, obtained by the local application of the model, and the corresponding windows of the original image are added. After that, veins in the enhanced image have been sufficiently emphasized. Thus, after image enhancement, an accurate segmentation can be obtained readily by a local entropy thresholding method. Finally, the resulted binary image may suffer from some misclassifications and, so, a postprocessing step is performed in order to extract a robust finger vein pattern. PMID:26120357
Flow Patterns in the Jugular Veins of Pulsatile Tinnitus Patients
Kao, Evan; Kefayati, Sarah; Amans, Matthew R.; Faraji, Farshid; Ballweber, Megan; Halbach, Van; Saloner, David
2017-01-01
Pulsatile Tinnitus (PT) is a pulse-synchronous sound heard in the absence of an external source. PT is often related to abnormal flow in vascular structures near the cochlea. One vascular territory implicated in PT is the internal jugular vein (IJV). Using computational fluid dynamics (CFD) based on patient-specific Magnetic Resonance Imaging (MRI), we investigated the flow within the IJV of seven subjects, four symptomatic and three asymptomatic of PT. We found that there were two extreme anatomic types classified by the shape and position of the jugular bulbs: elevated and rounded. PT patients had elevated jugular bulbs that led to a distinctive helical flow pattern within the proximal internal jugular vein. Asymptomatic subjects generally had rounded jugular bulbs that neatly redirected flow from the sigmoid sinus directly into the jugular vein. These two flow patterns were quantified by calculating the length-averaged streamline curvature of the flow within the proximal jugular vein: 130.3 ± 8.1 m-1 for geometries with rounded bulbs, 260.7 ± 29.4 m-1 for those with elevated bulbs (P < 0.005). Our results suggest that variations in the jugular bulb geometry lead to distinct flow patterns that are linked to PT, but further investigation is needed to determine if the vortex pattern is causal to sound generation. PMID:28057349
Full paleostress tensor reconstruction: case study of the Panasqueira Mine, Portugal.
NASA Astrophysics Data System (ADS)
Pascal, C.; Jaques Ribeiro, L. M.
2017-12-01
Paleostress tensor restoration methods are traditionally limited to reconstructing geometrical parameters and are unable to resolve stress magnitudes. Based on previous studies we further developed a methodology to restore full paleostress tensors. We concentrated on inversion of Mode I fractures and acquired data in Panasqueira Mine, Portugal, where optimal 3D exposures of mineralised quartz veins can be found. To carry out full paleostress restoration we needed to determine (1) pore (paleo)pressure and (2) vein attitudes. To these aims we conducted an extensive fluid inclusion study to derive fluid isochores from the quartz of the studied veins. To further constrain P-T conditions, we combined these isochores with crystallisation temperatures derived from geochemical analyses of coeval arsenopyrite. We also applied the sphalerite geobarometer and considered two other independent pressure indicators. Our results point to pore pressures of 300 MPa and formation depths of 10 km. As a second step, we measured 600 subhorizontal quartz veins in all the levels of the mine. The inversion of the attitudes of the veins allowed for reconstructing the orientations of the principal axes of stress, the unscaled Mohr circle and the relative pore pressure. After merging these results with the previously obtained absolute pore pressure we reconstructed the six parameters of the paleostress tensor.
Lee, Edward Y; Jenkins, Kathy J; Muneeb, Muhammad; Marshall, Audrey C; Tracy, Donald A; Zurakowski, David; Boiselle, Phillip M
2013-08-01
One of the important benefits of using multidetector computed tomography (MDCT) is its capability to generate high-quality two-dimensional (2-D) multiplanar (MPR) and three-dimensional (3-D) images from volumetric and isotropic axial CT data. However, to the best of our knowledge, no results have been published on the potential diagnostic role of multiplanar and 3-D volume-rendered (VR) images in detecting pulmonary vein stenosis, a condition in which MDCT has recently assumed a role as the initial noninvasive imaging modality of choice. The purpose of this study was to compare diagnostic accuracy and interpretation time of axial, multiplanar and 3-D VR images for detection of proximal pulmonary vein stenosis in children, and to assess the potential added diagnostic value of multiplanar and 3-D VR images. We used our hospital information system to identify all consecutive children (< 18 years of age) with proximal pulmonary vein stenosis who had both a thoracic MDCT angiography study and a catheter-based conventional angiography within 2 months from June 2005 to February 2012. Two experienced pediatric radiologists independently reviewed each MDCT study for the presence of proximal pulmonary vein stenosis defined as ≥ 50% of luminal narrowing on axial, multiplanar and 3-D VR images. Final diagnosis was confirmed by angiographic findings. Diagnostic accuracy was compared using the z-test. Confidence level of diagnosis (scale 1-5, 5 = highest), perceived added diagnostic value (scale 1-5, 5 = highest), and interpretation time of multiplanar or 3-D VR images were compared using paired t-tests. Interobserver agreement was measured using the chance-corrected kappa coefficient. The final study population consisted of 28 children (15 boys and 13 girls; mean age: 5.2 months). Diagnostic accuracy based on 116 individual pulmonary veins for detection of proximal pulmonary vein stenosis was 72.4% (84 of 116) for axial MDCT images, 77.5% (90 of 116 cases) for multiplanar MDCT images, and 93% (108 of 116 cases) for 3-D VR images with significantly higher accuracy with 3-D VR compared to axial (z = 4.17, P < 0.001) and multiplanar (z = 3.34, P < 0.001) images. Confidence levels for detection of proximal pulmonary vein stenosis were significantly higher with 3-D VR images (mean level: 4.6) compared to axial MDCT images (mean level: 1.7) and multiplanar MDCT images (mean level: 2.0) (paired t-tests, P < 0.001). Thus, 3-D VR images (mean added diagnostic value: 4.7) were found to provide added diagnostic value for detecting proximal pulmonary vein stenosis (paired t-test, P < 0.001); however, multiplanar MDCT images did not provide added value (paired t-test, P = 0.89). Interpretation time was significantly longer and interobserver agreement was higher when using 3-D VR images than using axial MDCT images or MPR MDCT images for diagnosing proximal pulmonary vein stenosis (paired t-tests, P < 0.001). Use of 3-D VR images in the diagnosis of proximal pulmonary vein stenosis in children significantly increases accuracy, confidence level, added diagnostic value and interobserver agreement. Thus, the routine use of this technique should be encouraged despite its increased interpretation time.
Improvements of deep vein reflux following radiofrequency ablation for saphenous vein incompetence.
Kim, Suh Min; Jung, In Mok; Chung, Jung Kee
2017-02-01
Objectives The aim of this study was to describe the changes of deep vein reflux after radiofrequency ablation for great saphenous vein incompetence. Method The data on 139 limbs which were treated with radiofrequency ablation for great saphenous vein incompetence were prospectively collected and reviewed. Results Deep vein reflux was present in 43 of 139 limbs (30.9%). There were no significant differences in the rate of successful closure, the incidence of procedure-related complications, and the improvements of symptoms and quality of life between the limbs with or without deep vein reflux. With a mean follow-up of 5.9 months, the peak reflux velocity and duration of reflux were improved in all limbs with deep vein reflux and it was completely corrected in 13 limbs (30.2%) after radiofrequency ablation. Conclusions The presence of deep vein reflux does not affect the treatment outcomes of radiofrequency ablation for great saphenous vein incompetence and is improved in all patients. Deep vein reflux is not a barrier to performing radiofrequency ablation.
Zollmann, Paul; Zollmann, Christine; Zollmann, Philipp; Veltman, Juergen; Kerzig, Dennis; Doerler, Martin; Stücker, Markus
2017-01-01
The purpose of this paper was to describe patterns of superficial reflux in the groin with respect to the terminal valve (TV), which is located at the saphenous opening to the common femoral vein, the great saphenous vein, and its tributary veins. This study included 2019 legs with chronic venous insufficiency that received endoluminal varicose vein treatment because of varicosities with insufficiency of the saphenofemoral junction (SFJ). In a preoperative duplex ultrasound investigation of the superficial vein system, reflux after provocation in the SFJ, great saphenous vein, cranial veins (superficial external pudendal vein, superficial epigastric vein, superficial circumflex iliac vein), and anterior and posterior accessory saphenous veins was recorded and classified on the basis of the origin of reflux. In 1348 legs (66.8%), the reflux had its origin exclusively in the common femoral vein. In 170 legs (8.4%), the reflux had its origin in the common femoral and cranial veins. In 430 legs (21.3%), the insufficiency was due to saphenocranial reflux only. In 71 legs (3.5%), the origin of reflux could not be determined. Reflux in the SFJ does not involve the TV in 24.8% of the legs, implying that routine high ligation and ablation close to the TV might be overtreatment in these patients. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Strier, Adam; Kravarusic, Dragan; Coran, Arnold G; Srugo, Isaac; Bitterman, Nir; Dorfman, Tatiana; Pollak, Yulia; Matter, Ibrahim; Sukhotnik, Igor
2017-02-01
Recent evidence suggests that elevated intra-abdominal pressure (IAP) may adversely affect the intestinal barrier function. Toll-like receptor 4 (TLR-4) is responsible for the recognition of bacterial endotoxin or lipopolysaccharide and for initiation of the Gram-negative septic shock syndrome. The objective of the current study was to determine the effects of elevated IAP on intestinal bacterial translocation (BT) and TLR-4 signaling in intestinal mucosa in a rat model. Male Sprague-Dawley rats were randomly assigned to one of two experimental groups: sham animals (Sham) and IAP animals who were subjected to a 15 mmHg pressure pneumoperitoneum for 30 minutes. Rats were sacrificed 24 hours later. BT to mesenteric lymph nodes, liver, portal vein blood, and peripheral blood was determined at sacrifice. TLR4-related gene and protein expression (TLR-4; myeloid differentiation factor 88 [Myd88] and TNF-α receptor-associated factor 6 [TRAF6]) expression were determined using real-time PCR, western blotting, and immunohistochemistry. Thirty percent of sham rats developed BT in the mesenteric lymph nodes (level I) and 20% of control rats developed BT in the liver and portal vein (level II). abdominal compartment syndrome (ACS) rats demonstrated an 80% BT in the lymph nodes (Level I) and 40% BT in the liver and portal vein (Level II). Elevated BT was accompanied by a significant increase in TLR-4 immunostaining in jejunum (51%) and ileum (35.9%), and in a number of TRAF6-positive cells in jejunum (2.1%) and ileum (24.01%) compared to control animals. ACS rats demonstrated a significant increase in TLR4 and MYD88 protein levels compared to control animals. Twenty-four hours after the induction of elevated IAP in a rat model, increased BT rates were associated with increased TLR4 signaling in intestinal mucosa.
NASA Astrophysics Data System (ADS)
mohan Behera, Bhuban; Thirukumaran, Venugopal; Biswal, Tapas kumar
2016-04-01
High grade metamorphism and intense deformation have given a well recognition to the Southern Granulite Terrane (SGT) in India. TTG-Charnockite and basic granulites constitute the dominant lithoassociation of the area. Dunite-peridotite-anorthosite-shonkinite and syenites are the intrusives. TTG-charnockite-basic granulite have undergone F1 (isoclinal recumbent), F2 (NE-SW) and F3 (NW-SE) folds producing several interference pattern. E-W trending Neoarchean and Palaeoproterozoic Salem-Attur Shear Zone exhibits a low angle ductile thrust as well as some foot print of late stage brittle deformation near Gangavalli area of Tamil Nadu. The thrust causes exhumation of basic granulites to upper crust. Thrusting along the decollement has retrograded the granulite into amphibolite rock. Subsequently, deformation pattern of Gangavalli area has distinctly marked by numerous vertical to sub-vertical fractures mostly dominating along 0-15 and 270-300 degree within charnockite hills that creates a maximum stress (σ1) along NNW and minimum stress (σ3) along ENE. However, emplacement of pseudotachylyte vein along N-S dominating fracture indicates a post deformational seismic event. Extensive fractures produce anastomose vein with varying thickness from few millimeters to 10 centimeters on the outcrop. ICP-AES study results an isochemical composition of pseudotachylyte vein that derived from the host charnockitic rock where it occurs. But still some noticeable variation in FeO-MgO and Na2O-CaO are obtained from different parts within the single vein showing heterogeneity melt. Electron probe micro analysis of thin sections reveals the existence of melt immiscibility during its solidification. Under dry melting condition, albitic rich melts are considered to be the most favorable composition for microlites (e.g. sheaf and acicular micro crystal) re-crystallization. Especially, acicular microlites preserved tachylite texture that suggest its formation before the final coagulation. Profuse sub-rounded clasts embedded in the melt are identified as hexagonal β-quartz (through XRD technique) that has undergone decrepitation along grain boundary. Thus partial melting of quartz can be suggested an ultrahigh temperature of 1550 degree Celsius has reached during formation of Gangavalli pseudotachylyte. Magmatic zircon grains from the pseudotachylyte veins are providing two age groups; the oldest ages are 2550±16 and 2508±14 Ma while the younger ages are 1848±24 and 1875±22 Ma. Here, we interpret that these zircons have no relation with the formation of pseudotachylyte because of its fast solidification. Hence, protolith belongs to 1848±24 and 1875±22 Ma age with xenocrysts of 2550±16 and 2508±14 Ma.
Theodoro, Daniel; Bausano, Brian; Lewis, Lawrence; Evanoff, Bradley; Kollef, Marin
2010-04-01
The safest site for central venous cannulation (CVC) remains debated. Many emergency physicians (EPs) advocate the ultrasound-guided internal jugular (USIJ) approach because of data supporting its efficiency. However, a number of physicians prefer, and are most comfortable with, the subclavian (SC) vein approach. The purpose of this study was to describe adverse event rates among operators using the USIJ approach, and the landmark SC vein approach without US. This was a prospective observational trial of patients undergoing CVC of the SC or internal jugular veins in the emergency department (ED). Physicians performing the procedures did not undergo standardized training in either technique. The primary outcome was a composite of adverse events defined as hematoma, arterial cannulation, pneumothorax, and failure to cannulate. Physicians recorded the anatomical site of cannulation, US assistance, indications, and acute complications. Variables of interest were collected from the pharmacy and ED record. Physician experience was based on a self-reported survey. The authors followed outcomes of central line insertion until device removal or patient discharge. Physicians attempted 236 USIJ and 132 SC cannulations on 333 patients. The overall adverse event rate was 22% with failure to cannulate being the most common. Adverse events occurred in 19% of USIJ attempts, compared to 29% of non-US-guided SC attempts. Among highly experienced operators, CVCs placed at the SC site resulted in more adverse events than those performed using USIJ (relative risk [RR] = 1.89, 95% confidence interval [CI] = 1.05 to 3.39). While limited by observational design, our results suggest that the USIJ technique may result in fewer adverse events compared to the landmark SC approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pyra, Krzysztof, E-mail: k.pyra@poczta.fm; Woźniak, Sławomir, E-mail: slavwo7572@gmail.com; Drelich-Zbroja, Anna, E-mail: zbroanna@interia.pl
PurposeThis study aimed to collect confirmatory data in support of the safety and efficiency of the ArtVentive EOS™ for the treatment of the pelvic congestion syndrome (PCS). This study was based on the OCCLUDE 1 Study Protocol approved by the Local Ethics Committee.Materials and MethodsA prospective study carried out in June and July 2014 included 12 women aged 21–48 years (mean 31 years) scheduled for PCS embolization using the ArtVentive EOS™. The inclusion criteria were clinical symptoms of PCS documented by transvaginal Doppler ultrasound and pelvic MRI. The pelvic pain was assessed by VAS score from 0 to 10 (0 represents lackmore » of pain and 10 unbearable pain). A decrease in pelvic pain intensity based on the VAS was considered a clinical success.ResultsSuccessful embolization procedures with ArtVentive EOS™ were performed in 11 out of 12 patients. Nine patients underwent unilateral embolization of the left ovarian vein, and two had bilateral embolization of the ovarian veins. Complete ovarian vein occlusion confirmed by post deployment venography was achieved in all 11 patients. Procedures lasted from 19 to 45 min (average 28 min). Pain intensity decrease was observed in all 11 patients—a decrease of 5.6 points—from 7.3 pre-procedure to 1.6 post-embolization (standard deviation: 0.67). In one case, the left ovarian vein was injured by guide wire manipulation with contrast extravasation—not clinically significant.ConclusionsThe use of ArtVentive EOS™ for occlusion of the ovarian veins in PCS patients is safe and effective.« less
Failure mode analysis in adrenal vein sampling: a single-center experience.
Trerotola, Scott O; Asmar, Melissa; Yan, Yan; Fraker, Douglas L; Cohen, Debbie L
2014-10-01
To analyze failure modes in a high-volume adrenal vein sampling (AVS) practice in an effort to identify preventable causes of nondiagnostic sampling. A retrospective database was constructed containing 343 AVS procedures performed over a 10-year period. Each nondiagnostic AVS procedure was reviewed for failure mode and correlated with results of any repeat AVS. Data collected included selectivity index, lateralization index, adrenalectomy outcomes if performed, and details of AVS procedure. All AVS procedures were performed after cosyntropin stimulation, using sequential technique. AVS was nondiagnostic in 12 of 343 (3.5%) primary procedures and 2 secondary procedures. Failure was right-sided in 8 (57%) procedures, left-sided in 4 (29%) procedures, bilateral in 1 procedure, and neither in 1 procedure (laboratory error). Failure modes included diluted sample from correctly identified vein (n = 7 [50%]; 3 right and 4 left), vessel misidentified as adrenal vein (n = 3 [21%]; all right), failure to locate an adrenal vein (n = 2 [14%]; both right), cosyntropin stimulation failure (n = 1 [7%]; diagnostic by nonstimulated criteria), and laboratory error (n = 1 [7%]; specimen loss). A second AVS procedure was diagnostic in three of five cases (60%), and a third AVS procedure was diagnostic in one of one case (100%). Among the eight patients in whom AVS ultimately was not diagnostic, four underwent adrenalectomy based on diluted AVS samples, and one underwent adrenalectomy based on imaging; all five experienced improvement in aldosteronism. A substantial percentage of AVS failures occur on the left, all related to dilution. Even when technically nondiagnostic per strict criteria, some "failed" AVS procedures may be sufficient to guide therapy. Repeat AVS has a good yield. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
van der Wijk, Anne-Eva; Schreurs, Malou P H; Cipolla, Marilyn J
2013-04-01
Pregnancy increases the risk of several complications associated with the cerebral veins, including thrombosis and hemorrhage. In contrast to the cerebral arteries and arterioles, few studies have focused on the effect of pregnancy on the cerebral venous side. Here, we investigated for the first time the effect of pregnancy on the function and structure of the cerebral vein of Galen in rats. Our major finding was that cerebral veins from late-pregnant (LP, n=11) rats had larger lumen diameters and thinner walls than veins from nonpregnant (NP, n=13) rats, indicating that pregnancy caused outward hypotrophic remodeling of the vein of Galen. Moreover, veins from NP animals had a small amount of myogenic tone at 10 mm Hg (3.9±1.0%) that was diminished in veins during pregnancy (0.8±0.3%; P<0.01). However, endothelium-dependent and -independent vasodilation of the veins was unchanged during pregnancy. Using immunohistochemistry, we show that the vein of Galen receives perivascular innervation, and that serotonergic innervation of cerebral veins is significantly higher in veins from LP animals. Outward hypotrophic remodeling and diminished tone of cerebral veins during pregnancy may contribute to the development of venous pathology through elevated wall tension and wall stress, and possibly by promoting venous blood stasis.
Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B
2014-12-01
62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival.
Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B.
2014-01-01
62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. Conclusion The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival. PMID:25568802
Numerical modelling of the formation of fibrous bedding-parallel veins
NASA Astrophysics Data System (ADS)
Torremans, Koen; Muchez, Philippe; Sintubin, Manuel
2014-05-01
Bedding-parallel veins with a fibrous infill oriented orthogonal to the vein wall, are often observed in fine-grained metasedimentary sequences. Several mechanisms have been proposed for their formation, mostly with respect to effects of fluid overpressures and anisotropy of the host-rock fabric in order to explain the inferred extensional failure with sub-vertical opening. Abundant pre-folding, bedding-parallel fibrous dolomite veins are found associated with the Nkana-Mindola stratiform Cu-Co deposit in Zambia. The goal of this study is to better understand the formation mechanisms of these veins and to explain their particular spatial and thickness distribution, with respect to failure of transversely isotropic rocks. The spatial distribution and thickness variation of these veins was quantified during a field campaign in thirteen line transects perpendicular to undeformed veins in underground crosscuts. The fibrous dolomite veins studied are not related to lithological contrasts, but to a strong bedding-parallel shaly fabric, typical for the black shale facies of the Copperbelt Orebody Member. The host rock can hence be considered as transversely isotropic. Growth morphologies vary from antitaxial with a pronounced median surface to asymmetric syntaxial, always with small but quantifiable growth competition. A microstructural fabric study reveals that the undeformed dolomite veins show low-tortuosity vein walls and quantifiable growth competition. Here, we use a Discrete Element Method numerical modelling approach with ESyS-Particle (http://launchpad.net/esys-particle) to simulate the observed properties of the veins. Calibrated numerical specimens with a transversely isotropic matrix are repeatedly brought to failure under constant strain rates by changing the effective strain rates at model boundaries. After each fracture event, fractures in the numerical model are filled with cohesive vein material and the experiment is repeated. By systematically varying stress states, fluid pressures and mechanical properties of materials (host rock, vein infill and interface), we attempt to reproduce the characteristics of spatial distribution and thickness variation of the veins. Four parameter sets of mechanical micro-properties are defined in the models, essentially yielding (1) a competent and (2) incompetent matrix, (3) a vein material and (4) a vein-matrix interface. Each combination of parameters and particle packings is calibrated to fit a predetermined Mohr-Coulomb type failure envelope, via an automated calibration procedure. Preliminary tests already show that by varying these parameters, we are able to simulate realistically distributed cracking through crack-seal processes. Different types of veins and vein generations can be modelled, ranging from single veins, over crack-seal veins to anastomosing veins, by varying the mechanical strength of competent and incompetent matrix, vein and interface material. Further results of this approach will be presented. We will discuss our results with respect to mechanisms proposed in the literature for bedding-parallel, fibrous veins in metasedimentary rock sequences.
Double external jugular vein and other rare venous variations of the head and neck.
Shenoy, Varsha; Saraswathi, Perumal; Raghunath, Gunapriya; Karthik, Jayakumar Sai
2012-12-01
Superficial veins of the head and neck are utilised for central venous cannulation, oral reconstruction and parenteral nutrition in debilitated patients. Clinical and sonological examinations of these veins may provide clues toward underlying cardiac pathology. Hence, although variations in these vessels are common, a sound knowledge of such variations becomes clinically important to surgeons, radiologists and interventional anaesthetists. We report a rare case of a left-sided double external jugular vein where the common facial vein continued as the second external jugular vein, and where there was a communicating channel between the internal jugular vein on the same side and the anterior jugular vein.
A review of the anatomy and clinical significance of adrenal veins.
Cesmebasi, Alper; Du Plessis, Maira; Iannatuono, Mark; Shah, Sameer; Tubbs, R Shane; Loukas, Marios
2014-11-01
The adrenal veins may present with a multitude of anatomical variants, which surgeons must be aware of when performing adrenalectomies. The adrenal veins originate during the formation of the prerenal inferior vena cava (IVC) and are remnants of the caudal portion of the subcardinal veins, cranial to the subcardinal sinus in the embryo. The many communications between the posterior cardinal, supracardinal, and subcardinal veins of the primordial venous system provide an explanation for the variable anatomy. Most commonly, one central vein drains each adrenal gland. The long left adrenal vein joins the inferior phrenic vein and drains into the left renal vein, while the short right adrenal vein drains immediately into the IVC. Multiple variations exist bilaterally and may pose the risk of surgical complications. Due to the potential for collaterals and accessory adrenal vessels, great caution must be taken during an adrenalectomy. Adrenal venous sampling, the gold standard in diagnosing primary hyperaldosteronism, also requires the clinician to have a thorough knowledge of the adrenal vein anatomy to avoid iatrogenic injury. The adrenal vein acts as an important conduit in portosystemic shunts, thus the nature of the anatomy and hypercoagulable states pose the risk of thrombosis. © 2014 Wiley Periodicals, Inc.
Morphology of congenital portosystemic shunts involving the left colic vein in dogs and cats.
White, R N; Parry, A T
2016-05-01
To describe the anatomy of congenital portosystemic shunts involving the left colic vein in dogs and cats. Retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. For inclusion a shunt involving the left colic vein with recorded intraoperative mesenteric portovenography or computed tomography angiography along with direct gross surgical observations at the time of surgery was required. Six dogs and three cats met the inclusion criteria. All cases had a shunt which involved a distended left colic vein. The final communication with a systemic vein was variable; in seven cases (five dogs, two cats) it was via the caudal vena cava, in one cat it was via the common iliac vein and in the remaining dog it was via the internal iliac vein. In addition, two cats showed caudal vena cava duplication. The morphology of this shunt type appeared to be a result of an abnormal communication between either the left colic vein or the cranial rectal vein and a pelvic systemic vein (caudal vena cava, common iliac vein or internal iliac vein). This information may help with surgical planning in cases undergoing shunt closure surgery. © 2016 British Small Animal Veterinary Association.
Felix, Valtuir Barbosa; Dos Santos, José André Bernardino; Fernandes, Katharina Jucá de Moraes; Cabral, Dhayanna Rolemberg Gama; Dos Santos, Carlos Adriano Silva; Rodrigues, Célio Fernando de Sousa; Lima, Jacqueline Silva Brito; Ramalho, Antônio José Casado
2016-01-01
The axillary vein is an important blood vessel that participates in drainage of the upper limb. Some individuals present a second axillary vein (accessory axillary vein), which is an important collateral drainage path. The goal of this study was to determine the incidence of the accessory axillary vein and to describe this vessel's topography. In this study, axillary dissections were carried out on twenty-four (24) human cadavers of both sexes that had been fixed with 10% formaldehyde. The upper limbs of the cadavers were still attached to the bodies and the axillary structures were preserved. Data collection was carried out and the axillary structures of the cadavers were compared. The incidence of accessory axillary veins was 58.3%, with no significant preference for sex or for side of the body. The accessory axillary vein originated from the lateral brachial vein in 39.28% of cases, from the common brachial vein in 35.71% of cases, and from the deep brachial vein in 25% of cases. Its high incidence and clinical relevance make the accessory axillary vein important for provision of collateral circulation in the event of traumatic injury to the axillary vein.
Qin, Jiangyi; Huang, Zhiping; Liu, Chunwu; Su, Shaojing; Zhou, Jing
2015-01-01
A novel blind recognition algorithm of frame synchronization words is proposed to recognize the frame synchronization words parameters in digital communication systems. In this paper, a blind recognition method of frame synchronization words based on the hard-decision is deduced in detail. And the standards of parameter recognition are given. Comparing with the blind recognition based on the hard-decision, utilizing the soft-decision can improve the accuracy of blind recognition. Therefore, combining with the characteristics of Quadrature Phase Shift Keying (QPSK) signal, an improved blind recognition algorithm based on the soft-decision is proposed. Meanwhile, the improved algorithm can be extended to other signal modulation forms. Then, the complete blind recognition steps of the hard-decision algorithm and the soft-decision algorithm are given in detail. Finally, the simulation results show that both the hard-decision algorithm and the soft-decision algorithm can recognize the parameters of frame synchronization words blindly. What's more, the improved algorithm can enhance the accuracy of blind recognition obviously.
Susceptibility-weighted imaging of the venous networks around the brain stem.
Cai, Ming; Zhang, Xiao-Fen; Qiao, Hui-Huang; Lin, Zhong-Xiao; Ren, Chuan-Gen; Li, Jian-Ce; Chen, Cheng-Chun; Zhang, Nu
2015-02-01
The venous network of the brainstem is complex and significant. Susceptibility-weighted imaging (SWI) is a practical technique which is sensitive to veins, especially tiny veins. Our purpose of this study was to evaluate the visualization of the venous network of brainstem by using SWI at 3.0 T. The occurrence rate of each superficial veins of brainstem was evaluated by using SWI on a 3 T MR imaging system in 60 volunteers. The diameter of the lateral mesencephalic vein and peduncular vein were measured by SWI using the reconstructed mIP images in the sagittal view. And the outflow of the veins of brainstem were studied and described according to the reconstructed images. The median anterior pontomesencephalic vein, median anterior medullary vein, peduncular vein, right vein of the pontomesencephalic sulcus, and right lateral anterior pontomesencephalic vein were detected in all the subjects (100%). The outer diameter of peduncular vein was 1.38 ± 0.26 mm (range 0.8-1.8 mm). The lateral mesencephalic vein was found in 75% of the subjects and the mean outer diameter was 0.81 ± 0.2 mm (range 0.5-1.2 mm). The inner veins of mesencephalon were found by using SWI. The venous networks around the brain stem can be visualized by SWI clearly. This result can not only provide data for anatomical study, but also may be available for the surgical planning in the infratentorial region.
Support vector machine-based facial-expression recognition method combining shape and appearance
NASA Astrophysics Data System (ADS)
Han, Eun Jung; Kang, Byung Jun; Park, Kang Ryoung; Lee, Sangyoun
2010-11-01
Facial expression recognition can be widely used for various applications, such as emotion-based human-machine interaction, intelligent robot interfaces, face recognition robust to expression variation, etc. Previous studies have been classified as either shape- or appearance-based recognition. The shape-based method has the disadvantage that the individual variance of facial feature points exists irrespective of similar expressions, which can cause a reduction of the recognition accuracy. The appearance-based method has a limitation in that the textural information of the face is very sensitive to variations in illumination. To overcome these problems, a new facial-expression recognition method is proposed, which combines both shape and appearance information, based on the support vector machine (SVM). This research is novel in the following three ways as compared to previous works. First, the facial feature points are automatically detected by using an active appearance model. From these, the shape-based recognition is performed by using the ratios between the facial feature points based on the facial-action coding system. Second, the SVM, which is trained to recognize the same and different expression classes, is proposed to combine two matching scores obtained from the shape- and appearance-based recognitions. Finally, a single SVM is trained to discriminate four different expressions, such as neutral, a smile, anger, and a scream. By determining the expression of the input facial image whose SVM output is at a minimum, the accuracy of the expression recognition is much enhanced. The experimental results showed that the recognition accuracy of the proposed method was better than previous researches and other fusion methods.
... This causes the veins to swell, which can lead to varicose veins. Varicose veins are very common. You are more at risk if you are older, are female, have obesity, don't exercise, or have a family history of varicose veins. They can also be more ...
NASA Astrophysics Data System (ADS)
Kowal-Linka, Monika
2010-03-01
Although bedding-parallel cone-in-cone structure calcite veins are present in the Middle Triassic Gogolin Formation in Opole Silesia, their occurrence is limited to the Emilówka Cellular Limestone Member. Marly limestones (dedolomites) consisting of calcite pseudospar are the host rocks. The veins, which are up to 3 mm high and 30 cm long, are built of densely packed cone columns, with individual cones up to 0.7 mm high and 0.6 mm wide at their bases, and with vertex angle values ranging from 30° to 50°. The cones are microfractured, and the adjacent cones are vertically shifted in oblique planes. The exceptionally small veins consist of calcite fibres up to 0.15 mm high. The veins are built of low-magnesium and non-ferroan calcite, characterized by low δ 18O values ranging from - 6.8‰ to - 7.4‰, and low δ 13C values ranging from - 2.9‰ to - 4.5‰ vs. PDB. These isotopic values are similar to those obtained from the host rocks (δ 18O from - 6.8‰ to - 7.4‰, and δ 13C from - 3.2‰ to - 3.6‰ vs. PDB) and they are strongly depleted in comparison with the isotopic values of other carbonate particles from the Gogolin Formation. The veins only formed in one lithostratigraphic member, suggesting that their origin is related to processes which acted only locally. There are two unique processes that the Emilówka Cellular Limestone Member alone in the Gogolin Formation underwent: early diagenetic evaporitic dolomitization of lime mud in the sabkha environment, and subsequent calcitization of dolomite. Dolomitization led to sediment cohesion loss, porosity increase and initial horizontal laminae separation as a result of the transformation of calcium carbonate to dolomite within anisotropic deposits. Similar values of geochemical parameters obtained from the vein calcite and the host rock calcite are evidence that vein-filling precipitation was contemporary with dedolomitization. Geochemical data combined with sedimentological research and burial history show meteoric-derived waters saturated with respect to calcite as a source of the vein calcite. Dedolomitization and vein precipitation may have taken place from the Norian/Early Jurassic to the Late Jurassic when the study area became eroded land, and the Emilówka Cellular Limestone Member may have acted as a local paleoaquifer conducting the meteoric-derived waters. Solid inclusions in the veins, detached from the host rock and the calcitized nodules, show that the force of calcite crystallization was the main factor responsible for vein widening. Vertical shifts of adjacent cones, remnants of primary fibrous calcite crystals, as well as the burial history justify the application of Tarr's theory in interpreting the origin of the secondary cone-in-cone structure within the fibrous structure veins. The timing and the particular conditions required for the cones to develop are uncertain.
Fault and fluid systems in supra-subduction zones: The Troodos ophiolite
NASA Astrophysics Data System (ADS)
Quandt, Dennis; Micheuz, Peter; Kurz, Walter; Krenn, Kurt
2017-04-01
The Troodos massif on the island of Cyprus represents a well-preserved and complete supra-subduction zone (SSZ) ophiolite. It includes an extrusive sequence that is subdivided into Upper (UPL) and Lower Pillow Lavas (LPL). These volcanic rocks contain mineralized fractures (veins) and vesicles that record fluid availability probably related to slab dehydration and deformation subsequent to a period of subduction initiation in the framework of a SSZ setting. Here, we present electron microprobe element mappings and cathodoluminescence studies of vein minerals as well as analyses of fluid inclusions entrapped in zeolite, calcite and quartz from veins and vesicles of the Pillow Lavas of the Troodos ophiolite. Two different zeolite type assemblages, interpreted as alteration products of compositional varying volcanic glasses, occur: (1) Na-zeolites analcime and natrolite from the UPL that require lower formation temperatures, higher Na/Ca ratios and pH values than (2) Ca-zeolites heulandite and mordenite from the LPL which indicate temporal or spatial varying fluid compositions and conditions. Calcite represents a late stage phase in incompletely sealed blocky type (1) assemblage and in syntaxial quartz veins. Additionally, calcite occurs as major phase in syntaxial and blocky veins of UPL and LPL. These syntaxial quartz and calcite veins are assumed to be related to tectonic extension. Chalcedony is associated with quartz and occurs in typical veins and vesicles of the LPL. In addition, the presence of neptunian dykes in veins suggests that seawater penetrated fractures throughout the extrusive sequence. Thus, circulation in an open system via advective transport is favored while diffusion in a closed system is a subordinate, local and late stage phenomenon. Calcite veins and quartz vesicles contain primary, partly re-equilibrated two phase (liquid, vapor) fluid inclusions. The chemical system of all studied inclusions in both host minerals is restricted to aqueous chemistry with salinities below 5 mass% based on last melting of ice between -3 and -0.8° C. Homogenization around 100-200° C occurs always to the liquid phase indicative for a pressure dominated fluid origin. Well preserved zonation textures in blocky calcite veins consisting of partly decrepitated but also re-equilibrated large fluid inclusions are related to Mn-rich areas. This fluid inclusion generation shows also homogenization to the liquid phase and points to minimum temperature conditions for formation of Mn-enriched areas of about 220° C. Calcite microstructures within the veins are characterized by type I and II twins as well as undulatory extinction and subgrain boundaries indicative for deformation temperatures of approximately 200-250° C, with differential stresses of about 50 MPa. We acknowledge financial support by the Austrian Research Fund (P27982-N29) to W. Kurz
Biological and mechanical interplay at the Macro- and Microscales Modulates the Cell-Niche Fate.
Sarig, Udi; Sarig, Hadar; Gora, Aleksander; Krishnamoorthi, Muthu Kumar; Au-Yeung, Gigi Chi Ting; de-Berardinis, Elio; Chaw, Su Yin; Mhaisalkar, Priyadarshini; Bogireddi, Hanumakumar; Ramakrishna, Seeram; Boey, Freddy Yin Chiang; Venkatraman, Subbu S; Machluf, Marcelle
2018-03-02
Tissue development, regeneration, or de-novo tissue engineering in-vitro, are based on reciprocal cell-niche interactions. Early tissue formation mechanisms, however, remain largely unknown given complex in-vivo multifactoriality, and limited tools to effectively characterize and correlate specific micro-scaled bio-mechanical interplay. We developed a unique model system, based on decellularized porcine cardiac extracellular matrices (pcECMs)-as representative natural soft-tissue biomaterial-to study a spectrum of common cell-niche interactions. Model monocultures and 1:1 co-cultures on the pcECM of human umbilical vein endothelial cells (HUVECs) and human mesenchymal stem cells (hMSCs) were mechano-biologically characterized using macro- (Instron), and micro- (AFM) mechanical testing, histology, SEM and molecular biology aspects using RT-PCR arrays. The obtained data was analyzed using developed statistics, principal component and gene-set analyses tools. Our results indicated biomechanical cell-type dependency, bi-modal elasticity distributions at the micron cell-ECM interaction level, and corresponding differing gene expression profiles. We further show that hMSCs remodel the ECM, HUVECs enable ECM tissue-specific recognition, and their co-cultures synergistically contribute to tissue integration-mimicking conserved developmental pathways. We also suggest novel quantifiable measures as indicators of tissue assembly and integration. This work may benefit basic and translational research in materials science, developmental biology, tissue engineering, regenerative medicine and cancer biomechanics.
Varicose vein - noninvasive treatment
Sclerotherapy; Laser therapy - varicose veins; Radiofrequency vein ablation; Endovenous thermal ablation; Ambulatory phlebectomy; Transilluminated power phlebotomy; Endovenous laser ablation; Varicose vein therapy
Renal ammonia metabolism and transport.
Weiner, I David; Verlander, Jill W
2013-01-01
Renal ammonia metabolism and transport mediates a central role in acid-base homeostasis. In contrast to most renal solutes, the majority of renal ammonia excretion derives from intrarenal production, not from glomerular filtration. Renal ammoniagenesis predominantly results from glutamine metabolism, which produces 2 NH4(+) and 2 HCO3(-) for each glutamine metabolized. The proximal tubule is the primary site for ammoniagenesis, but there is evidence for ammoniagenesis by most renal epithelial cells. Ammonia produced in the kidney is either excreted into the urine or returned to the systemic circulation through the renal veins. Ammonia excreted in the urine promotes acid excretion; ammonia returned to the systemic circulation is metabolized in the liver in a HCO3(-)-consuming process, resulting in no net benefit to acid-base homeostasis. Highly regulated ammonia transport by renal epithelial cells determines the proportion of ammonia excreted in the urine versus returned to the systemic circulation. The traditional paradigm of ammonia transport involving passive NH3 diffusion, protonation in the lumen and NH4(+) trapping due to an inability to cross plasma membranes is being replaced by the recognition of limited plasma membrane NH3 permeability in combination with the presence of specific NH3-transporting and NH4(+)-transporting proteins in specific renal epithelial cells. Ammonia production and transport are regulated by a variety of factors, including extracellular pH and K(+), and by several hormones, such as mineralocorticoids, glucocorticoids and angiotensin II. This coordinated process of regulated ammonia production and transport is critical for the effective maintenance of acid-base homeostasis.
Chambers, Brian; Chambers, Jayne; Churilov, Leonid; Cameron, Heather; Macdonell, Richard
2014-09-01
We evaluated internal jugular vein and vertebral vein volume flow using ultrasound, in patients with clinically isolated syndrome or mild multiple sclerosis and controls, to determine whether volume flow was different between the two groups. In patients and controls, internal jugular vein volume flow increased from superior to inferior segments, consistent with recruitment from collateral veins. Internal jugular vein and vertebral vein volume flow were greater on the right in supine and sitting positions. Internal jugular vein volume flow was higher in the supine posture. Vertebral vein volume flow was higher in the sitting posture. Regression analyses of cube root transformed volume flow data, adjusted for supine/sitting, right/left and internal jugular vein/vertebral vein, revealed no significant difference in volume flow in patients compared to controls. Our findings further refute the concept of venous obstruction as a causal factor in the pathogenesis of multiple sclerosis. Control volume flow data may provide useful normative reference values. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Salnikova, Lyubov E; Khadzhieva, Maryam B; Kolobkov, Dmitry S
2016-07-01
Pelvic floor dysfunction, specifically genital prolapse (GP) and stress urinary inconsistency (SUI) presumably co-occur with other connective tissue disorders such as hernia, hemorrhoids, and varicose veins. Observations on non-random coexistence of these disorders have never been summarized in a meta-analysis. The performed meta-analysis demonstrated that varicose veins and hernia are associated with GP. Disease connections on the molecular level may be partially based on shared genetic susceptibility. A unique opportunity to estimate shared genetic susceptibility to disorders is provided by a PheWAS (phenome-wide association study) designed to utilize GWAS data concurrently to many phenotypes. We searched the PheWAS Catalog, which includes the results of the PheWAS study with P value < 0.05, for genes associated with GP, SUI, abdominal hernia, varicose veins and hemorrhoids. We found pronounced signals for the associations of the SLC2A9 gene with SUI (P = 6.0e-05) and the MYH9 gene with varicose veins of lower extremity (P = 0.0001) and hemorrhoids (P = 0.0007). The comparison of the PheWAS Catalog and the NHGRI Catalog data revealed enrichment of genes associated with bone mineral density in GP and with activated partial thromboplastin time in varicose veins of lower extremity. In cross-phenotype associations, genes responsible for peripheral nerve functions seem to predominate. This study not only established novel biologically plausible associations that may warrant further studies but also exemplified an effective use of the PheWAS Catalog data.
Extrahepatic Portal Vein Obstruction in Children: Role of Preoperative Imaging.
Achar, Shashidhar; Dutta, Hemonta Kumar; Gogoi, Rudra Kanta
2017-01-01
Extrahepatic portal vein obstruction (EHPVO) is characterized by features of recent thrombosis or portal hypertension with portal cavernoma as a sequel of portal vein obstruction. Imaging of spleno-portal axis is the mainstay for the diagnosis of EHPVO. The aim of this study is to analyze the role of imaging in the preoperative assessment of the portal venous system in children with EHPVO. A hospital-based cross-sectional study was conducted on twenty children with EHPVO aged between 1 and 18 years over a period of 1 year. The children were evaluated clinically, followed by upper gastrointestinal endoscopy. Radiological assessment included imaging of the main portal vein, its right and left branches, splenic vein, and superior mesenteric vein using color Doppler ultrasonography (CDUSG) and magnetic resonance portovenogram (MRP). Evidence of portal biliopathy, status of collaterals, and possible sites for portosystemic shunt surgery were also examined. All the patients presented in chronic stage with portal cavernoma and only one patient (5%) had bland thrombus associated with cavernoma. The CDUSG and MRPs had a sensitivity of 66.6-90% and 96.7% and specificity of 91.5% and 98.3% respectively with regard to the assessment of the extent of thrombus formation and flow in the portal venous system. Both the modalities were found to be complementary to each other in preoperative assessment of EHPVO. However, the sensitivity of MRP was slightly superior to CDUSG in detecting occlusion and identifying portosystemic collaterals and dilated intrahepatic biliary radicals. Results of the present study indicate that MRP is well suited and superior to CDUSG in the preoperative imaging of patients with EHPVO.
Female Pelvic Vein Embolization: Indications, Techniques, and Outcomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopez, Anthony James, E-mail: consultant@radiologist.co.uk
Until recently, the main indication for pelvic vein embolization (PVE) in women was to treat pelvic venous congestion syndrome (PVC) but increasingly, patients with refluxing pelvic veins associated with leg varicosities are also being treated. A more unusual reason for PVE is to treat pelvic venous malformations, although such lesions may be treated with sclerotherapy alone. Embolotherapy for treating PVC has been performed for many years with several published studies included in this review, whilst an emerging indication for PVE is to treat lower limb varicosities associated with pelvic vein reflux. Neither group, however, has been subjected to an adequatemore » randomized, controlled trial. Consequently, some of the information presented in this review should be considered anecdotal (level III evidence) at this stage, and a satisfactory ‘proof’ of clinical efficacy remains deficient until higher-level evidence is presented. Furthermore, a wide range of techniques not accepted by all are used, and some standardization will be required based on future mandatory prospective studies. Large studies have also clearly shown an unacceptably high recurrence rate of leg varicose veins following venous surgery. Furthermore, minimally or non-invasive imaging is now revealing that there is a refluxing pelvic venous source in a significant percentage of women with de novo leg varicose veins, and many more with recurrent varicosities. Considering that just over half the world’s population is female and a significant number of women not only have pelvic venous reflux, but also have associated leg varicosities, minimally invasive treatment of pelvic venous incompetence will become a common procedure.« less
Kermani, Abbas Jafari; Fathi, Fardin; Mowla, Seyed Javad
2008-04-01
Stem cells are defined by two main characteristics: self-renewal capacity and commitment to multi-lineage differentiation. The cells have a great therapeutic potential in repopulating damaged tissues as well as being genetically manipulated and used in cell-based gene therapy. Umbilical cord vein is a readily available and inexpensive source of stem cells that are capable of generating various cell types. Despite the recent isolation of human umbilical cord vein mesenchymal stem cells (UVMSC), the self-renewal capacity and the potential clinical application of the cells are not well known. In the present study, we have successfully isolated and cultured human UVMSCs. Our data further revealed that the isolated cells express the self-renewal genes Oct-4, Nanog, ZFX, Bmi-1, and Nucleostemin; but not Zic-3, Hoxb-4, TCL-1, Tbx-3 and Esrrb. In addition, our immunocytochemistry results revealed the expression of SSEA-4, but not SSEA-3, TRA-1-60, and TRA-1-81 embryonic stem cell surface markers in the cells. Also, we were able to transfect the cells with a reporter, enhanced green fluorescent protein (EGFP), and a therapeutic human brain-derived neurotrophic factor (hBDNF) gene by means of electroporation and obtained a stable cell line, which could constantly express both transgenes. The latter data provide further evidence on the usefulness of umbilical cord vein mesenchymal stem cells as a readily available source of stem cells, which could be genetically manipulated and used in cell-based gene therapy applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schellhammer, Frank, E-mail: frank.schellhammer@med.uni-duesseldorf.d; Esch, Jan Schulte am; Hammerschlag, Sascha
2008-07-15
Portal vein thrombosis is an infrequent entity, which may cause high morbidity and mortality. We report a case of portal vein thrombosis due to benign stenosis following partial pancreatoduodenectomy with segmental replacement of the portal vein by a Gore-tex graft. Using a surgical access to jenunal veins, local thrombolysis, mechanical fragmentation of thrombus, and stent placement were successfully performed.
Bröder, Arndt; Malejka, Simone
2017-07-01
The experimental manipulation of response biases in recognition-memory tests is an important means for testing recognition models and for estimating their parameters. The textbook manipulations for binary-response formats either vary the payoff scheme or the base rate of targets in the recognition test, with the latter being the more frequently applied procedure. However, some published studies reverted to implying different base rates by instruction rather than actually changing them. Aside from unnecessarily deceiving participants, this procedure may lead to cognitive conflicts that prompt response strategies unknown to the experimenter. To test our objection, implied base rates were compared to actual base rates in a recognition experiment followed by a post-experimental interview to assess participants' response strategies. The behavioural data show that recognition-memory performance was estimated to be lower in the implied base-rate condition. The interview data demonstrate that participants used various second-order response strategies that jeopardise the interpretability of the recognition data. We thus advice researchers against substituting actual base rates with implied base rates.
NASA Astrophysics Data System (ADS)
Sun, Zhengquan; Zeng, Zuoxun; Wu, Linbo; Xu, Shaopeng; Yang, Shuang; Chen, Deli; Wang, Jianxiu
2017-05-01
New results, in combination with previously published ones, reveal that when the Stress Exponent of the Competent layer (SEC) ranges from 1 to 10 (1 < n < 10), Pinch-and-Swell structure Rheology Gauge (PSRG) can only be available under the condition that the Viscosity ratio between the Competent layer and its corresponding Matrix layer (VCM) is larger than 10. Therefore, we made the attempt to calculate the viscosity ratio of pinch-and-swell structure of competent layer to the related matrix and stress exponent. Based on this knowledge, we applied this gauge to calculate SECs and VCMs of eight types of pinch-and-swell structures, which are widely developed in the Taili area of the west Liaoning Province in China. Statistical analysis of the SEC resulted in intervals of four types of competent layers, that is, Medium-scale Granitic coarse-to-pegmatitic Veins, Small-scale Augen Granite aplite Veins, Small-scale Granite aplite Veins, and Small-scale Augen Quartz-K-feldspar veins, with intervals of [3.50, 4.63], [2.64, 4.29], [2.70, 3.51], and [2.50, 3.36] respectively. The preferred intervals of VCM of the five types of pinch-and-swell structures, Small-scale Augen Granite aplite Veins + Fine-grained Biotite-Hornblende-plagioclase Gneiss, Medium-scale Granitic coarse-to-pegmatitic Veins + Fine-grained Biotite-Hornblende-plagioclase Gneiss, Small-scale Augen Granite aplite Veins + medium-to-fine-grained granitic gneiss, Medium-scale Granitic coarse-to-pegmatitic Veins + medium-to-fine-grained granitic gneiss, and Small-scale Augen Granite aplite Veins + fine-grained biotite-plagioclase gneiss, are [19.98, 62.51], [15.90, 61.17], [26.72, 93.27], [22.21, 107.26], and [76.33, 309.39] respectively. The similarities between these calculated SEC statistical preferred intervals and the physical experimental results verify the validity of the PSRG. The competent layers of the pinch-and-swell structures were presented in this study as power-law flow with SEC values that increased with the thickness of the layer. Grain-size plays an important role in the rheology of pinch-and-swell structures. The results offer a case for the application of PSRG and determine the key rock rheological parameters of North China Craton for future related studies.
Shilal, Poonam; Tuli, Anita
2015-03-01
The pattern of drainage in the right posterior lobe of liver varies considerably. The knowledge of this variation is very important while performing various surgeries on the right posterior lobe. A study was conducted to see the variations in the pattern of drainage of posterior segment of the right lobe of liver. The aim was to see the variations of right hepatic vein and small accessory hepatic veins draining the posterior segment, the presence of which led to modifications in drainage of posterior segment. Sixty formalin fixed adult human liver specimens were dissected manually. According to the pattern of drainage of tributaries of right hepatic vein, the right hepatic vein was classified into type I, type II, type III and type IV. According to presence of inferior right hepatic vein, three types of drainage of posterior lobe were seen: Type I, (76.36%) right hepatic vein was large, draining wide area of posterior segment. A small inferior right hepatic vein drained the small area of posterior segment. In Type II, (19.92%) both right hepatic and inferior right hepatic veins were medium sized draining the posteroinferior segment of the right lobe concomitantly. In Type III, (32%) accessory veins, the middle right hepatic vein drained the posterosuperior (VII) as well as the posteroinferior (VI) segment. In one specimen, there were numerous middle right hepatic veins draining the right posterior segment. The knowledge of anatomic relationship of veins draining right lobe, is important in performing right posterior segmentectomy. For safe resection of the liver, the complex anatomy of the distribution of the tributaries of the right hepatic vein and the accessory veins have to be studied prior to any surgery done on liver.
Percutaneous Portal Vein Access and Transhepatic Tract Hemostasis
Saad, Wael E. A.; Madoff, David C.
2012-01-01
Percutaneous portal vein interventions require minimally invasive access to the portal venous system. Common approaches to the portal vein include transjugular hepatic vein to portal vein access and direct transhepatic portal vein access. A major concern of the transhepatic route is the risk of postprocedural bleeding, which is increased when patients are anticoagulated or receiving pharmaceutical thrombolytic therapy. Thus percutaneous portal vein access and subsequent closure are important technical parts of percutaneous portal vein procedures. At present, various techniques have been used for either portal access or subsequent transhepatic tract closure and hemostasis. Regardless of the method used, meticulous technique is required to achieve the overall safety and effectiveness of portal venous procedures. This article reviews the various techniques of percutaneous transhepatic portal vein access and the various closure and hemostatic methods used to reduce the risk of postprocedural bleeding. PMID:23729976
Hong, Yong Kook; Kang, Kyung Hoon; Kim, Tae Hwan; Yang, Hee Chul
2018-03-01
We report a case of vein rupture by Arrow-Trerotola percutaneous thrombolytic device (Trerotola PTD) during a treatment of thrombosed arteriovenous graft (AVG). A 77-year-old woman with a problem of thrombosed AVG underwent an endovascular treatment including a procedure of angioplasty of axillary vein. After angioplasty of axillary vein, we found a newly developed thrombus in axillary vein and performed thrombolysis using an over-the-wire 7F Trerotola PTD. When the rotating cage of the device arrived at axillary vein, it suddenly stopped, fixed at the angioplasty site, and didn't move at all. Venogram showed an extravasation of contrast media at axillary vein, suggesting vein rupture. The patient underwent an emergency operation. It could be dangerous to use Trerotola PTD in a native vein immediately after angioplasty.
A proof-of-concept study of the VeinScrew: A new percutaneous venous closure device.
Boersma, Doeke; de Borst, Gert Jan; Moll, Frans L
2017-02-01
Objective This study evaluated the concept of percutaneous closure of insufficient veins using the VeinScrew principle. Methods The VeinScrew is designed to place a spring-shaped implant that contracts and clamps around the vein. The ability of the device to occlude adequately was tested in a bench model experiment. The feasibility of accurate placement and adequate venous occlusion was evaluated in an animal experiment and in a human cadaveric experiment. Results The VeinScrew implant occluded up to a pressure of 135 mmHg. In vivo studies confirmed that deployment was challenging but technically feasible, and subsequent phlebography showed closure of the vein. The cadaveric study showed that percutaneous placement of the evolved VeinScrew around the great saphenous vein was feasible and accurate. Conclusions The current studies show the feasibility of the VeinScrew concept. Future developments and translational studies are necessary to determine the potential of this technique as a new option in the phlebologist's toolbox.
Formal implementation of a performance evaluation model for the face recognition system.
Shin, Yong-Nyuo; Kim, Jason; Lee, Yong-Jun; Shin, Woochang; Choi, Jin-Young
2008-01-01
Due to usability features, practical applications, and its lack of intrusiveness, face recognition technology, based on information, derived from individuals' facial features, has been attracting considerable attention recently. Reported recognition rates of commercialized face recognition systems cannot be admitted as official recognition rates, as they are based on assumptions that are beneficial to the specific system and face database. Therefore, performance evaluation methods and tools are necessary to objectively measure the accuracy and performance of any face recognition system. In this paper, we propose and formalize a performance evaluation model for the biometric recognition system, implementing an evaluation tool for face recognition systems based on the proposed model. Furthermore, we performed evaluations objectively by providing guidelines for the design and implementation of a performance evaluation system, formalizing the performance test process.
NASA Astrophysics Data System (ADS)
Taetz, Stephan; John, Timm; Bröcker, Michael; Spandler, Carl; Stracke, Andreas
2018-01-01
A better understanding of the subduction zone fluid cycle and its chemical-mechanical feedback requires in-depth knowledge about how fluids flow within and out of descending slabs. Relicts of fluid-flow systems in exhumed rocks of fossil subduction zones allow for identification of the general relationships between dehydration reactions, fluid pathway formation, the dimensions and timescales of distinct fluid flow events; all of which are required for quantitative models for fluid-induced subduction zone processes. Two types of garnet-quartz-phengite veins can be distinguished in an eclogite-facies mélange block from the Pouébo Eclogite Mélange, New Caledonia. These veins record synmetamorphic internal fluid release by mineral breakdown reactions (type I veins), and infiltration of an external fluid (type II veins) with the associated formation of a reaction selvage. The dehydration and fluid migration documented by the type I veins likely occurred on a timescale of 105-106 years, based on average subduction rates and metamorphic conditions required for mineral dehydration and fluid flow. The timeframe of fluid-rock interaction between the external fluid and the wall-rock of the type II veins is quantified using a continuous bulk-rock Li-diffusion profile perpendicular to a vein and its metasomatic selvage. Differences in Li concentration between the internal and external fluid reservoirs resulted in a distinct diffusion profile (decreasing Li concentration and increasing δ7 Li) as the reaction front propagated into the host rock. Li-chronometric constraints indicate that the timescales of fluid-rock interaction associated with type II vein formation are on the order of 1 to 4 months (0.150-0.08+0.14 years). The short-lived, pulse-like character of this process is consistent with the notion that fluid flow caused by oceanic crust dehydration at the blueschist-to-eclogite transition contributes to or even dominates episodic pore fluid pressure increases at the plate interface, which in turn, may trigger slip events reported from many subduction zones.
McKown, Athena D; Cochard, Hervé; Sack, Lawren
2010-04-01
Leaf venation architecture is tremendously diverse across plant species. Understanding the hydraulic functions of given venation traits can clarify the organization of the vascular system and its adaptation to environment. Using a spatially explicit model (the program K_leaf), we subjected realistic simulated leaves to modifications and calculated the impacts on xylem and leaf hydraulic conductance (K(x) and K(leaf), respectively), important traits in determining photosynthesis and growth. We tested the sensitivity of leaves to altered vein order conductivities (1) in the absence or (2) presence of hierarchical vein architecture, (3) to major vein tapering, and (4) to modification of vein densities (length/leaf area). The K(x) and K(leaf) increased with individual vein order conductivities and densities; for hierarchical venation systems, the greatest impact was from increases in vein conductivity for lower vein orders and increases in density for higher vein orders. Individual vein order conductivities were colimiting of K(x) and K(leaf), as were their densities, but the effects of vein conductivities and densities were orthogonal. Both vein hierarchy and vein tapering increased K(x) relative to xylem construction cost. These results highlight the important consequences of venation traits for the economics, ecology, and evolution of plant transport capacity.
Bi, Lianxiang; Wacker, Bradley K; Bueren, Emma; Ham, Ervin; Dronadula, Nagadhara; Dichek, David A
2017-12-15
Coronary artery bypass vein grafts are a mainstay of therapy for human atherosclerosis. Unfortunately, the long-term patency of vein grafts is limited by accelerated atherosclerosis. Gene therapy, directed at the vein graft wall, is a promising approach for preventing vein graft atherosclerosis. Because helper-dependent adenovirus (HDAd) efficiently transduces grafted veins and confers long-term transgene expression, HDAd is an excellent candidate for delivery of vein graft-targeted gene therapy. We developed a model of vein graft atherosclerosis in fat-fed rabbits and demonstrated long-term (≥20 weeks) persistence of HDAd genomes after graft transduction. This model enables quantitation of vein graft hemodynamics, wall structure, lipid accumulation, cellularity, vector persistence, and inflammatory markers on a single graft. Time-course experiments identified 12 weeks after transduction as an optimal time to measure efficacy of gene therapy on the critical variables of lipid and macrophage accumulation. We also used chow-fed rabbits to test whether HDAd infusion in vein grafts promotes intimal growth and inflammation. HDAd did not increase intimal growth, but had moderate-yet significant-pro-inflammatory effects. The vein graft atherosclerosis model will be useful for testing HDAd-mediated gene therapy; however, pro-inflammatory effects of HdAd remain a concern in developing HDAd as a therapy for vein graft disease.
Felix, Valtuir Barbosa; dos Santos, José André Bernardino; Fernandes, Katharina Jucá de Moraes; Cabral, Dhayanna Rolemberg Gama; dos Santos, Carlos Adriano Silva; Rodrigues, Célio Fernando de Sousa; Lima, Jacqueline Silva Brito; Ramalho, Antônio José Casado
2016-01-01
Abstract Background The axillary vein is an important blood vessel that participates in drainage of the upper limb. Some individuals present a second axillary vein (accessory axillary vein), which is an important collateral drainage path. Objectives The goal of this study was to determine the incidence of the accessory axillary vein and to describe this vessel’s topography. Methods In this study, axillary dissections were carried out on twenty-four (24) human cadavers of both sexes that had been fixed with 10% formaldehyde. The upper limbs of the cadavers were still attached to the bodies and the axillary structures were preserved. Data collection was carried out and the axillary structures of the cadavers were compared. Results The incidence of accessory axillary veins was 58.3%, with no significant preference for sex or for side of the body. The accessory axillary vein originated from the lateral brachial vein in 39.28% of cases, from the common brachial vein in 35.71% of cases, and from the deep brachial vein in 25% of cases. Conclusions Its high incidence and clinical relevance make the accessory axillary vein important for provision of collateral circulation in the event of traumatic injury to the axillary vein.
Page, Michael M; Taranto, Mario; Ramsay, Duncan; van Schie, Greg; Glendenning, Paul; Gillett, Melissa J; Vasikaran, Samuel D
2018-01-01
Objective Primary aldosteronism is a curable cause of hypertension which can be treated surgically or medically depending on the findings of adrenal vein sampling studies. Adrenal vein sampling studies are technically demanding with a high failure rate in many centres. The use of intraprocedural cortisol measurement could improve the success rates of adrenal vein sampling but may be impracticable due to cost and effects on procedural duration. Design Retrospective review of the results of adrenal vein sampling procedures since commencement of point-of-care cortisol measurement using a novel single-use semi-quantitative measuring device for cortisol, the adrenal vein sampling Accuracy Kit. Success rate and complications of adrenal vein sampling procedures before and after use of the adrenal vein sampling Accuracy Kit. Routine use of the adrenal vein sampling Accuracy Kit device for intraprocedural measurement of cortisol commenced in 2016. Results Technical success rate of adrenal vein sampling increased from 63% of 99 procedures to 90% of 48 procedures ( P = 0.0007) after implementation of the adrenal vein sampling Accuracy Kit. Failure of right adrenal vein cannulation was the main reason for an unsuccessful study. Radiation dose decreased from 34.2 Gy.cm 2 (interquartile range, 15.8-85.9) to 15.7 Gy.cm 2 (6.9-47.3) ( P = 0.009). No complications were noted, and implementation costs were minimal. Conclusions Point-of-care cortisol measurement during adrenal vein sampling improved cannulation success rates and reduced radiation exposure. The use of the adrenal vein sampling Accuracy Kit is now standard practice at our centre.
Individual recognition based on communication behaviour of male fowl.
Smith, Carolynn L; Taubert, Jessica; Weldon, Kimberly; Evans, Christopher S
2016-04-01
Correctly directing social behaviour towards a specific individual requires an ability to discriminate between conspecifics. The mechanisms of individual recognition include phenotype matching and familiarity-based recognition. Communication-based recognition is a subset of familiarity-based recognition wherein the classification is based on behavioural or distinctive signalling properties. Male fowl (Gallus gallus) produce a visual display (tidbitting) upon finding food in the presence of a female. Females typically approach displaying males. However, males may tidbit without food. We used the distinctiveness of the visual display and the unreliability of some males to test for communication-based recognition in female fowl. We manipulated the prior experience of the hens with the males to create two classes of males: S(+) wherein the tidbitting signal was paired with a food reward to the female, and S (-) wherein the tidbitting signal occurred without food reward. We then conducted a sequential discrimination test with hens using a live video feed of a familiar male. The results of the discrimination tests revealed that hens discriminated between categories of males based on their signalling behaviour. These results suggest that fowl possess a communication-based recognition system. This is the first demonstration of live-to-video transfer of recognition in any species of bird. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Vaselli, Luca; Cortecci, Gianni; Tonarini, Sonia; Ottria, Giuseppe; Mussi, Mario
2012-11-01
This work deals with structural and geochemical (chemical and isotopic) analyses of calcite veins hosted in Carrara marbles in the Alpi Apuane, NW Tuscany, Italy. Geometric features and spatial distribution of veins provided estimations of stress ratio (Φ = (σ2 - σ3)/(σ1 - σ3)), driving stress ratio (R' = (Pf - σ3)/(σ1 - σ3)) and fluid overpressure (Δsi = Pf - σ3) at the time of vein formation. The obtained values of Φ = 32 and R' = 0.43 reveal that fluid pressure was higher than the intermediate principal stress at the time of veins formation, whereas the estimated Δsi ranging from 129 to 207 MPa indicates that veins formed under supra-hydrostatic to lithostatic pressure conditions. Carbon (δ13CV-PDB = 1.81-2.10‰ for veins and 1.95-2.51‰ for host marbles), oxygen (δ18OV-SMOW = 28.71-29.57‰ for veins and 28.90-29.36‰ for host marbles) and strontium (87Sr/86Sr = 0.707716-0.707985 for veins and 0.0707708-0.707900 for host marbles) isotope compositions in vein/host marble pairs were internally quite consistent. Combining our structural and geochemical data, a modeling approach was performed to investigate the compositional features and temperatures of calcite depositing fluids. The results of our studies give evidence that (1) pore-fluids in Carrara marble, consisting of metamorphic formation waters, were re-mobilized during veining event and migrated within the veins in closed system conditions, (2) veins formed after ductile folding phases and before high-angle brittle faulting events, at temperature and pressure around 250 °C and 210 MPa, and finally (3) about 12 g H2O/m3 marble are calculated to have been available as vein parental fluid at the time of vein formation.
Konoeda, Hisato; Yamaki, Takashi; Hamahata, Atsumori; Ochi, Masakazu; Osada, Atsuyoshi; Hasegawa, Yuki; Kirita, Miho; Sakurai, Hiroyuki
2017-05-01
Background Breast reconstruction is associated with multiple risk factors for venous thromboembolism. However, the incidence of deep vein thrombosis in patients undergoing breast reconstruction is uncertain. Objective The aim of this study was to prospectively evaluate the incidence of deep vein thrombosis in patients undergoing breast reconstruction using autologous tissue transfer and to identify potential risk factors for deep vein thrombosis. Methods Thirty-five patients undergoing breast reconstruction were enrolled. We measured patients' preoperative characteristics including age, body mass index (kg/m 2 ), and risk factors for deep vein thrombosis. The preoperative diameter of each venous segment in the deep veins was measured using duplex ultrasound. All patients received intermittent pneumatic pump and elastic compression stockings for postoperative thromboprophylaxis. Results Among the 35 patients evaluated, 11 (31.4%) were found to have deep vein thrombosis postoperatively, and one patient was found to have pulmonary embolism postoperatively. All instances of deep vein thrombosis developed in the calf and were asymptomatic. Ten of 11 patients underwent free flap transfer, and the remaining one patient received a latissimus dorsi pedicled flap. Deep vein thrombosis incidence did not significantly differ between patients with a free flap or pedicled flap (P = 0.13). Documented risk factors for deep vein thrombosis demonstrated no significant differences between patients with and without deep vein thrombosis. The diameter of the common femoral vein was significantly larger in patients who developed postoperative deep vein thrombosis than in those who did not ( P < 0.05). Conclusions The morbidity of deep vein thrombosis in patients who underwent breast reconstruction using autologous tissue transfer was relatively high. Since only the diameter of the common femoral vein was predictive of developing postoperative deep vein thrombosis, postoperative pharmacological thromboprophylaxis should be considered for all patients undergoing breast reconstruction regardless of operative procedure.
A CONTROLLED TECHNIQUE FOR VEIN STRIPPING
Gordon, Milton; Payne, Robert D.
1953-01-01
A number of difficulties encountered in vein stripping operations for varicose veins in the legs have been overcome by use of a technique evolved by adaptation and modifications of various reported methods. The stripping instrument is passed from below upward, the valves or branches offering less impediment to its passage in that direction. Inserting the tip of the instrument at the ankle through an incision in the vein while it is still in continuity is easier than introducing it into the end of a transected vein. Ligation of major superficial branches or subfascial division of communicating veins can be readily carried out while the stripper is still in place in the vein. Applying pressure bandages to the entire length of the leg before removing the stripper and the telescoped vein diminishes the chances of ecchymosis yet does not hinder withdrawal of the instrument and the vein. PMID:13106726
Patterns and Rates of Supplementary Venous Drainage to the Internal Jugular Veins.
Qureshi, Adnan I; Ishfaq, Muhammad Fawad; Herial, Nabeel A; Khan, Asif A; Suri, M Fareed K
2016-07-01
Several studies have found supplemental venous drainage channels in addition to bilateral internal jugular veins for cerebral venous efflux. We performed this study to characterize the supplemental venous outflow patterns in a consecutive series of patients undergoing detailed cerebral angiography with venous phase imaging. The venographic phase of the arteriogram was reviewed to identify and classify supplemental cerebral venous drainage into anterior (cavernous venous sinus draining into pterygoid plexus and retromandibular vein) and posterior drainage pattern. The posterior drainage pattern was further divided into plexiform pattern (with sigmoid venous sinus draining into the paravertebral venous plexus), and solitary vein pattern (dominant single draining deep cervical vein) drainage. The posterior plexiform pattern was further divided into 2 groups: posterior plexiform with or without prominent solitary vein. Supplemental venous drainage was seen ipsilateral to internal jugular vein in 76 (43.7%) of 174 venous drainages (87 patients) analyzed. The patterns were anterior (n = 23, 13.2%), posterior plexiform without prominent solitary vein (n = 40, 23%), posterior plexiform with prominent solitary vein (n = 62, 35.6%), and posterior solitary vein alone (n = 3, 1.7%); occipital emissary veins and/or transosseous veins were seen in 1 supplemental venous drainage. Concurrent ipsilateral anterior and posterior supplemental drainage was seen in 6 of 174 venous drainages analyzed. We provide an assessment of patterns and rates of supplementary venous drainage to internal jugular veins to improve our understanding of anatomical and physiological aspects of cerebral venous drainage. Copyright © 2016 by the American Society of Neuroimaging.
Episodic vein formation in Gale crater, Mars: evidence for an extended history of liquid water
NASA Astrophysics Data System (ADS)
Kronyak, R. E.; Fedo, C.; Banham, S.; Edgett, K. S.; Newsom, H. E.; Nachon, M.; Kah, L. C.
2017-12-01
The sedimentary rock record of Gale crater is consistent with deposition in an ancient lake basin. These strata represent aqueous and potentially habitable past conditions that existed over a relatively small part of Mars' geologic history. Post-depositional fluid migration is recorded by the presence of veins, which have been prevalent features throughout Curiosity's mission. These veins record later episodes of fluid flow and represent an extended history of liquid water stability, and perhaps habitability. White Ca-sulfate veins are observed in the Bradbury (Yellowknife Bay), Mount Sharp (Murray formation), and Siccar Point (Stimson formation) groups across a range of lithologies. At Yellowknife Bay and in the Stimson, Ca-sulfate veins characteristically exhibit mm-scale thicknesses. In the Pahrump Hills (PH) area, 62% of measured veins in the Murray formation are <3 mm thick. However, PH also contains a population of veins that range from 1-5 cm thick that commonly contain gray inclusions and are crosscut by thinner white veins. Similar gray material occurs along the interface between wall rock and Ca-sulfate and is interpreted as a precursor vein fill. Gray veins at PH are more erosionally resistant relative to Ca-sulfate and average 1 mm in width. Additionally, gray veins exhibit elevated Mg and depleted Ca, distinguishing them compositionally from Ca-sulfate veins. Veins continue locally throughout the stratigraphic section. The lowermost Stimson sandstones at the Missoula outcrop contain white clasts and elevated Ca-sulfate, suggesting the formation of Murray veins prior to the deposition of the Stimson formation. Near the Old Soaker outcrop, bedding-parallel sulfate may represent syndepositional gypsum precipitation. In the context of time, the multiple vein systems identified in the Gale crater sedimentary fill shed light on the sequence and evolution of fluids responsible for their deposition. It is envisioned that sulfates first precipitated contemporaneously with the deposition of the Murray formation, followed by burial, lithification, and fracturing to form the earliest gray and sulfate veins. The Murray was then exhumed and eroded, followed by deposition and lithification of the Stimson formation, fracturing, and precipitation of the latest sulfate veins.
Wolf, H; Gross, F; Merz, A; Schuler, A
2013-03-01
Liver segment definition due to Couinaud is the basis for localisation of focal liver lesions in imaging, in the follow-up or for planning operations. A literature review shows variety in segment definition and the frontier between segment II and III in the left liver lobe, in the course of the portal vein level and in variations of liver veins. The aim of this study is to demonstrate liver segment anatomy in sonography compared to anatomic preparations and the literature. This leads to a proposal for a unique nomenclature and illustration. 152 liver healthy persons (77 F, 75 M, mean age 63.3 years (18 - 91 years) were examined with standardised abdominal ultrasound in longitudinal, transversal and axis planes. (Angle) measurements were taken to define the left hepatic vein (Fissura sinistra), the Ramus umbilicalis of the portal vein (Fissura umbilicalis), the portal vein level and the amount and variations of the liver veins. The left hepatic vein was found with a mean angle of 24° (0 - 70°) left to the median axis, the Pars umbilicalis of the portal vein wasalmost strictly in the mid axis. The portal vein level was located with a mean angle of 61° (5 - 110°) right to the median with no variations of the two main branches. 27 (18 %) out of the remaining 151 patients showed variations of the liver veins: 7 × (4.6 %) a doubled mid hepatic vein, 12 × (8 %) a doubled left hepatic vein, 4 × (2.7 %) 3 left liver veins were found with a short (≤ 1 cm) common trunk, 1 × each (0.7 %) four left liver veins with a short common trunk, one trifurcation of the mid hepatic vein, one doubled right liver vein and one common trunk (2 cm) of all 3 main liver veins leading to the inferior V. cava. The surgical functional liver segment definition by Couinaud is the basis for localisation of focal liver lesions. The frontier between segment II and III is mainly described as a horizontal plane in the literature. The course of the left liver vein (fissura sinistra) has a mean angle of 24° left to the median and not like the umbilical fissure, which is found almost strictly in the median plane. The left hepatic vein(s), their course and liver vein variations are well demonstrated by sonography (99.3 % in this study). Anatomic landmarks as well as variations and a unique nomenclature should be well known and considered in the localisation of focal liver lesions, their feeding vessels and liver segment anatomy. © Georg Thieme Verlag KG Stuttgart · New York.
Davies, Huw Ob; Popplewell, Matthew; Bate, Gareth; Kelly, Lisa; Darvall, Katy; Bradbury, Andrew W
2016-10-01
Although varicose veins are a common cause of morbidity, the UK National Health Service and private medical insurers have previously sought to ration their treatment in a non-evidence based manner in order to limit health-care expenditure and reimbursement. In July 2013, the UK National Institute for Health and Care Excellence published new national Clinical Guidelines (CG168) to promote evidence-based commissioning and management of varicose veins. The aim of this study was to evaluate the impact of CG168 on the referral and management of varicose veins at the Heart of England NHS Foundation Trust, Birmingham, UK. Interrogation of a prospectively gathered database, provided by the Heart of England NHS Foundation Trust Performance Unit, of patients undergoing interventions for varicose veins since 1 January 2012. Patients treated before (group 1) and after (group 2) publication of CG168 were compared. There were 253 patients, 286 legs (48% male, mean (range) age 54 (20-91) years) treated in group 1, and 417 patients, 452 legs, (46% male, mean (range) age 54 (14-90) years) treated in group 2, an increase of 65%. CG168 was associated with a significant reduction in the use of surgery (131 patients (52%) group 1 vs. 127 patients (30%) group 2, p = 0.0003, χ(2)), no change in endothermal ablation (30 patients (12%) group 1 vs. 45 patients (11%) group 2), a significant increase in ultrasound-guided foam sclerotherapy (92 patients (36%) group 1 and 245 patients (59%) group 2, p = 0.0001, χ(2)) and an increase in treatment for C2/3 disease (53% group 1 and 65.2% group 2, p = 0.0022, χ(2)). Publication of National Institute for Health and Care Excellence CG168 has been associated with a significant increase (65%) in the number of patients treated, referral at an earlier (CEAP C) stage and increased use of endovenous treatment. CG 168 has been highly effective in improving access to, and quality of care, for varicose veins at Heart of England NHS Foundation Trust. © The Author(s) 2015.
Uldahl, Kristine Buch; Wu, Linping; Hall, Arnaldur; Papathanasiou, Pavlos; Peng, Xu; Moghimi, Seyed Moein
2016-01-01
Viruses from the third domain of life, Archaea, exhibit unusual features including extreme stability that allow their survival in harsh environments. In addition, these species have never been reported to integrate into human or any other eukaryotic genomes, and could thus serve for exploration of novel medical nanoplatforms. Here, we selected two archaeal viruses Sulfolobus monocaudavirus 1 (SMV1) and Sulfolobus spindle shaped virus 2 (SSV2) owing to their unique spindle shape, hyperthermostable and acid-resistant nature and studied their interaction with mammalian cells. Accordingly, we followed viral uptake, intracellular trafficking and cell viability in human endothelial cells of brain (hCMEC/D3 cells) and umbilical vein (HUVEC) origin. Whereas SMV1 is efficiently internalized into both types of human cells, SSV2 differentiates between HUVECs and hCMEC/D3 cells, thus opening a path for selective cell targeting. On internalization, both viruses localize to the lysosomal compartments. Neither SMV1, nor SSV2 induced any detrimental effect on cell morphology, plasma membrane and mitochondrial functionality. This is the first study demonstrating recognition of archaeal viruses by eukaryotic cells which provides good basis for future exploration of archaeal viruses in bioengineering and development of multifunctional vectors. PMID:27892499
Fifty years of progress in speech and speaker recognition
NASA Astrophysics Data System (ADS)
Furui, Sadaoki
2004-10-01
Speech and speaker recognition technology has made very significant progress in the past 50 years. The progress can be summarized by the following changes: (1) from template matching to corpus-base statistical modeling, e.g., HMM and n-grams, (2) from filter bank/spectral resonance to Cepstral features (Cepstrum + DCepstrum + DDCepstrum), (3) from heuristic time-normalization to DTW/DP matching, (4) from gdistanceh-based to likelihood-based methods, (5) from maximum likelihood to discriminative approach, e.g., MCE/GPD and MMI, (6) from isolated word to continuous speech recognition, (7) from small vocabulary to large vocabulary recognition, (8) from context-independent units to context-dependent units for recognition, (9) from clean speech to noisy/telephone speech recognition, (10) from single speaker to speaker-independent/adaptive recognition, (11) from monologue to dialogue/conversation recognition, (12) from read speech to spontaneous speech recognition, (13) from recognition to understanding, (14) from single-modality (audio signal only) to multi-modal (audio/visual) speech recognition, (15) from hardware recognizer to software recognizer, and (16) from no commercial application to many practical commercial applications. Most of these advances have taken place in both the fields of speech recognition and speaker recognition. The majority of technological changes have been directed toward the purpose of increasing robustness of recognition, including many other additional important techniques not noted above.
Random-Profiles-Based 3D Face Recognition System
Joongrock, Kim; Sunjin, Yu; Sangyoun, Lee
2014-01-01
In this paper, a noble nonintrusive three-dimensional (3D) face modeling system for random-profile-based 3D face recognition is presented. Although recent two-dimensional (2D) face recognition systems can achieve a reliable recognition rate under certain conditions, their performance is limited by internal and external changes, such as illumination and pose variation. To address these issues, 3D face recognition, which uses 3D face data, has recently received much attention. However, the performance of 3D face recognition highly depends on the precision of acquired 3D face data, while also requiring more computational power and storage capacity than 2D face recognition systems. In this paper, we present a developed nonintrusive 3D face modeling system composed of a stereo vision system and an invisible near-infrared line laser, which can be directly applied to profile-based 3D face recognition. We further propose a novel random-profile-based 3D face recognition method that is memory-efficient and pose-invariant. The experimental results demonstrate that the reconstructed 3D face data consists of more than 50 k 3D point clouds and a reliable recognition rate against pose variation. PMID:24691101
Magmatic Fluid Source of the Chingshui Geothermal Field: Evidence of Carbonate Isotope data
NASA Astrophysics Data System (ADS)
Song, S. R.; Lu, Y. C.; Wang, P. L.; John, C. M.; MacDonald, J.
2015-12-01
The Chingshui geothermal field is located at the northern tip of the Miocene Lushan Slate Formation, which was part of the Eurasian continental margin subject to the Plio-Pleistocene collision associated with the Luzon Arc. The remnant heat of the Taiwan orogeny has long been considered to drive the circulation of hydrothermal fluids in the Chingshui geothermal field. However, recent studies based on magnetic anomalies and helium isotopic ratios suggest that the heat might instead be derived from igneous bodies. By examining isotope data of calcite veins and scaling in geothermal wells, this study aimed to clarify the fluid origin and possible heat source accounting for the geothermal fluids in the Chingshui geothermal field. Carbon and oxygen isotope analyses indicate that veins from outcrops and scalings in geothermal wells have high and low d values, respectively. Data for veins in drilled cores fall in between outcrop veins and scalings values. Such an isotopic pattern could be interpreted as the mixing of two end member fluids. The clumped isotope analysis of calcite veins from the outcrops yielded precipitation temperatures of up to 232 ± 16 ℃ and a reconstructed d18O fluid value of 9.5 ‰(magmatic fluid: 6-11 ‰; metamorphic fluid: 5-28 ‰ by Taylor, 1974). The inferred d18O values of hot fluids for the vein formation are significantly different from that of meteoric water in Chingshui area (around -5.4 ‰) as well as the scaling in geothermal wells (around -7.6 ‰). Previous study of magnetotelluric image demonstrated two possible fluid reservoirs at different depths (Chen et al. 2012). Our isotope data combined with these lines of evidence suggest that the scaling in geothermal wells could be derived from fluids originating from the shallower reservoir. In contrast, the veins present at outcrops could have been formed from 18O-enriched, deeply-sourced fluids related to either metamorphic dehydration or magmatic processes.
Sahoo, Sushanta K; Ghuman, Mandeep S; Salunke, Pravin; Vyas, Sameer; Bhar, Rahat; Khandelwal, N K
2016-01-01
The ligation and transection of anterior third of superior sagittal sinus (AT-SSS) is an important step to approach anterior skull base lesions. Some clinical studies have shown frontal lobe venous infarct following such surgical procedures questioning the safety of its ligation. We have studied the variations in venous drainage patterns to AT-SSS in the normal population using postcontrast magnetic resonance venogram (MRV). A novel scoring system to recognize the subgroup with dominant venous drainage from frontal lobes has been described. In this study, 60 three-dimensional contrast-enhanced (CE) MRVs were obtained from those cases being evaluated for a headache not harboring any intracranial mass lesion. The AT-SSS with all its draining veins was studied in detail. Morphology of individual veins such as length, caliber, tributaries, and angulation with AT-SSS was studied, and a numerical value of 0 or 1 was assigned for each of the above parameters. Summing up these scores derived from the individual cortical veins quantified the drainage of AT-SSS. There are 3-4 veins on either side draining to AT-SSS. Barely, 3% of the veins had > 3 tributaries. Only 6.6% of veins had a caliber >3 mm, and 16.5% drained at acute angles to AT-SSS. About 26% of the veins did cross at least half of the lateral frontal lobe. We found in 26 individuals the AT-SSS score was 0-2, in 22 it was 3-5 and, in only in 12 (20%) the score was 6 or more (dominant drainage). There are anatomical variations in venous drainage of frontal lobes into AT-SSS. Those with dominant drainage are likely to develop venous congestion and complications if sacrificed. It is possible to identify these individuals on the basis of venous drainage pattern as shown in CE-MRV.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Busser, Wendy M. H., E-mail: wendy.busser@radboudumc.nl; Arntz, Mark J.; Jenniskens, Sjoerd F. M.
2015-08-15
PurposeWe assessed whether image registration of cone-beam computed tomography (CT) (CBCT) and contrast-enhanced CT (CE-CT) images indicating the locations of the adrenal veins can aid in increasing the success rate of first-attempts adrenal vein sampling (AVS) and therefore decreasing patient radiation dose.Materials and Methods CBCT scans were acquired in the interventional suite (Philips Allura Xper FD20) and rigidly registered to the vertebra in previously acquired CE-CT. Adrenal vein locations were marked on the CT image and superimposed with live fluoroscopy and digital-subtraction angiography (DSA) to guide the AVS. Seventeen first attempts at AVS were performed with image registration and retrospectivelymore » compared with 15 first attempts without image registration performed earlier by the same 2 interventional radiologists. First-attempt AVS was considered successful when both adrenal vein samples showed representative cortisol levels. Sampling time, dose-area product (DAP), number of DSA runs, fluoroscopy time, and skin dose were recorded.ResultsWithout image registration, the first attempt at sampling was successful in 8 of 15 procedures indicating a success rate of 53.3 %. This increased to 76.5 % (13 of 17) by adding CBCT and CE-CT image registration to AVS procedures (p = 0.266). DAP values (p = 0.001) and DSA runs (p = 0.026) decreased significantly by adding image registration guidance. Sampling and fluoroscopy times and skin dose showed no significant changes.ConclusionGuidance based on registration of CBCT and previously acquired diagnostic CE-CT can aid in enhancing localization of the adrenal veins thereby increasing the success rate of first-attempt AVS with a significant decrease in the number of used DSA runs and, consequently, radiation dose required.« less
Watanabe, Nobuyuki; Yamamoto, Yusuke; Sugiura, Teiichi; Okamura, Yukiyasu; Ito, Takaaki; Ashida, Ryo; Aramaki, Takeshi; Uesaka, Katsuhiko
2018-05-01
The factors which affect hypertrophy of the future liver remnant after portal vein embolization remain unclear. The aim of this study was to clarify the clinical factors affecting the hypertrophy rate after portal vein embolization and to develop a scoring system predicting insufficient liver hypertrophy. The cases of a total of 152 patients who underwent portal vein embolization of the right portal branch between 2006 and 2016 were reviewed retrospectively. The score to predict insufficient (<25%) hypertrophy was established based on logistic regression analyses of the clinical parameters before portal vein embolization. After portal vein embolization, the future liver remnant volume, expressed as the median (range), significantly increased from 364 (151-801) mL, 33% (18%-54%), to 451 (242-866) mL, 42% (26%-65%). The median hypertrophy rate was 24% (-5% to 96%). A preoperative predictive scoring system for insufficient liver hypertrophy was constructed using the following 3 factors: an initial future liver remnant volume ≥35% (2 points), alkaline phosphatase ≥450 IU/dL (1 point), and cholinesterase <220 mg/dL (1 point). The constructed scoring system indicated the proportion of patients with insufficient liver hypertrophy (<25%) to be 6 out of 42 (14%) in the low-score group (0 points), 44 out of 77 (57%) in the medium-score group (1-2 points), and 30 out of 33 (91%) in the high-score group (3-4 points). The hypertrophy rate of future liver remnant was different among the 3 groups (low-score group, 38.9% [-2.4% to 81.4%]; medium-score group, 22.7% [-5.1% to 95.5%]; high-score group, 18.2% [2.4%-30.7%]) (P < .001). The constructed scoring system was able to stratify patients before portal vein embolization according to the possibility of developing insufficient liver hypertrophy. Copyright © 2017 Elsevier Inc. All rights reserved.
Osgood, Michael J.; Harrison, David G.; Sexton, Kevin W.; Hocking, Kyle M.; Voskresensky, Igor V.; Komalavilas, Padmini; Cheung-Flynn, Joyce; Guzman, Raul J.; Brophy, Colleen M.
2014-01-01
The saphenous vein remains the most widely used conduit for peripheral and coronary revascularization despite a high rate of vein graft failure. The most common cause of vein graft failure is intimal hyperplasia. No agents have been proven to be successful for the prevention of intimal hyperplasia in human subjects. The rennin–angiotensin system is essential in the regulation of vascular tone and blood pressure in physiologic conditions. However, this system mediates cardiovascular remodeling in pathophysiologic states. Angiotensin II is becoming increasingly recognized as a potential mediator of intimal hyperplasia. Drugs modulating the renin–angiotensin system include angiotensin-converting enzyme inhibitors and angiotensin receptor blockers. These drugs are powerful inhibitors of atherosclerosis and cardiovascular remodeling, and they are first-line agents for management of several medical conditions based on class I evidence that they delay progression of cardiovascular disease and improve survival. Several experimental models have demonstrated that these agents are capable of inhibiting intimal hyperplasia. However, there are no data supporting their role in prevention of intimal hyperplasia in patients with vein grafts. This review summarizes the physiology of the rennin–angiotensin system, the role of angiotensin II in the pathogenesis of cardiovascular remodeling, the medical indications for these agents, and the experimental data supporting an important role of the rennin–angiotensin system in the pathogenesis of intimal hyperplasia. PMID:22445245
Endoscopic saphenous vein and radial harvest: state-of-the-art.
Bisleri, Gianluigi; Muneretto, Claudio
2015-11-01
Over the past decade, there has been an increased adoption of minimally invasive techniques for saphenous vein and radial artery procurement during coronary artery bypass surgery, albeit concerns have been raised about the potential detrimental effects of the endoscopic approach when compared with the conventional 'open' technique. The aim of the present review is to analyse the current available techniques and evidence about the impact of an endoscopic approach on conduit quality and clinical outcomes. At present, the available techniques for endoscopic vessel harvesting can be based on a sealed or non-sealed concept, for both saphenous vein and radial artery procurement. Despite the proven advantages of a minimally invasive approach in terms of reduced incidence of wound complications, pain reduction and improved cosmetic results, some studies questioned the impact of this technique in terms of potential graft damage, thus impairing the longevity of the graft itself. Endoscopic conduit harvesting can be performed safely and effectively with the currently available techniques, albeit a careful knowledge of the pitfalls of each technique is mandatory. Since there is ample evidence in literature that a minimally invasive approach for saphenous vein and radial artery procurement is not associated with an increased risk of graft damage and related failure in the mid-long term, the endoscopic technique should be adopted as the approach of choice for saphenous vein and radial artery harvesting in coronary artery bypass graft surgery.
NASA Astrophysics Data System (ADS)
Noordmans, Herke J.; Rutten, G. J. M.; Willems, Peter W. A.; Hoogduin, J.; Viergever, Max A.
2001-01-01
The visualization of brain vessels on the cortex helps the neurosurgeon in two ways: To avoid blood vessels when specifying the trepanation entry, and to overcome errors in the surgical navigation system due to brain shift. We compared 3D T1 MR, 3D T1 MR with gadolinium contrast, MR venography and MR phase contrast angiography as scanning techniques, mutual information as registration technique, and thresholding and multi-vessel enhancement as image processing techniques. We evaluated the volume rendered results based on their quality and correspondence with photos took during surgery. It appears that with 3D T1 MR scans, gadolinium is required to show cortical veins. The visibility of small cortical veins is strongly enhanced by subtracting a 3D T1 MR baseline scan, which should be registered to the scan with gadolinium contrast, even when the scans are made during the same session. Multi-vessel enhancement helps to clarify the view on small vessels by reducing the noise level, but strikingly does not reveal more. MR venography does show intracerebral veins with high detail, but is, as is, unsuited to show cortical veins due to the low contrast with CSF. MR phase contrast angiography can perform equally well as the subtraction technique, but its quality seems to show more inter-patient variability.
NASA Astrophysics Data System (ADS)
Joshi, Vinayak S.; Garvin, Mona K.; Reinhardt, Joseph M.; Abramoff, Michael D.
2011-03-01
Structural analysis of retinal vessel network has so far served in the diagnosis of retinopathies and systemic diseases. The retinopathies are known to affect the morphologic properties of retinal vessels such as course, shape, caliber, and tortuosity. Whether the arteries and the veins respond to these changes together or in tandem has always been a topic of discussion. However the diseases such as diabetic retinopathy and retinopathy of prematurity have been diagnosed with the morphologic changes specific either to arteries or to veins. Thus a method describing the separation of retinal vessel trees imaged in a two dimensional color fundus image may assist in artery-vein classification and quantitative assessment of morphologic changes particular to arteries or veins. We propose a method based on mathematical morphology and graph search to identify and label the retinal vessel trees, which provides a structural mapping of vessel network in terms of each individual primary vessel, its branches and spatial positions of branching and cross-over points. The method was evaluated on a dataset of 15 fundus images resulting into an accuracy of 92.87 % correctly assigned vessel pixels when compared with the manual labeling of separated vessel trees. Accordingly, the structural mapping method performs well and we are currently investigating its potential in evaluating the characteristic properties specific to arteries or veins.
Container-code recognition system based on computer vision and deep neural networks
NASA Astrophysics Data System (ADS)
Liu, Yi; Li, Tianjian; Jiang, Li; Liang, Xiaoyao
2018-04-01
Automatic container-code recognition system becomes a crucial requirement for ship transportation industry in recent years. In this paper, an automatic container-code recognition system based on computer vision and deep neural networks is proposed. The system consists of two modules, detection module and recognition module. The detection module applies both algorithms based on computer vision and neural networks, and generates a better detection result through combination to avoid the drawbacks of the two methods. The combined detection results are also collected for online training of the neural networks. The recognition module exploits both character segmentation and end-to-end recognition, and outputs the recognition result which passes the verification. When the recognition module generates false recognition, the result will be corrected and collected for online training of the end-to-end recognition sub-module. By combining several algorithms, the system is able to deal with more situations, and the online training mechanism can improve the performance of the neural networks at runtime. The proposed system is able to achieve 93% of overall recognition accuracy.
Anaphylaxis with angioedema by rocuronium during induction of general anesthesia -A case report-
Jeong, Won Ju; Son, Joo Hyung; Lee, Yoon-Sook; Kim, Jae Hwan; Park, Young Cheol
2010-01-01
Perioperative anaphylaxis is characterized by severe respiratory and cardiovascular manifestations. Correct management of anaphylaxis during anaesthesia requires a multidisciplinary approach with prompt recognition and treatment of the acute event by the attending anesthesiologist. A 34-year-old woman was scheduled to undergo endo venous laser therapy of varicose veins. She had no history of allergies and had never undergone general anesthesia. General anesthesia was induced with propofol and rocuronium bromide. Approximately three minutes after rocuronium administration, hypotension and tachycardia developed and angioedema around the eyelids and skin rashes and urticaria appeared. The patient received ephedrine and hydrocortisone with hydration. After achieving stable vital signs and symptom relief, surgery was performed without complications. A postoperative skin dermal test performed to identify the agent responsible revealed a positive skin test for rocuronium. PMID:20508798
The principles of cryostratigraphy
NASA Astrophysics Data System (ADS)
French, Hugh; Shur, Yuri
2010-08-01
Cryostratigraphy adopts concepts from both Russian geocryology and modern sedimentology. Structures formed by the amount and distribution of ice within sediment and rock are termed cryostructures. Typically, layered cryostructures are indicative of syngenetic permafrost while reticulate and irregular cryostructures are indicative of epigenetic permafrost. 'Cryofacies' can be defined according to patterns of sediment characterized by distinct ice lenses and layers, volumetric ice content and ice-crystal size. Cryofacies can be subdivided according to cryostructure. Where a number of cryofacies form a distinctive cryostratigraphic unit, these are termed a 'cryofacies assemblage'. The recognition, if present, of (i) thaw unconformities, (ii) other ice bodies such as vein ice (ice wedges), aggradational ice and thermokarst-cave ('pool') ice, and (iii) ice, sand and gravelly pseudomorphs is also important in determining the nature of the freezing process, the conditions under which frozen sediment accumulates, and the history of permafrost.
Modal-Power-Based Haptic Motion Recognition
NASA Astrophysics Data System (ADS)
Kasahara, Yusuke; Shimono, Tomoyuki; Kuwahara, Hiroaki; Sato, Masataka; Ohnishi, Kouhei
Motion recognition based on sensory information is important for providing assistance to human using robots. Several studies have been carried out on motion recognition based on image information. However, in the motion of humans contact with an object can not be evaluated precisely by image-based recognition. This is because the considering force information is very important for describing contact motion. In this paper, a modal-power-based haptic motion recognition is proposed; modal power is considered to reveal information on both position and force. Modal power is considered to be one of the defining features of human motion. A motion recognition algorithm based on linear discriminant analysis is proposed to distinguish between similar motions. Haptic information is extracted using a bilateral master-slave system. Then, the observed motion is decomposed in terms of primitive functions in a modal space. The experimental results show the effectiveness of the proposed method.
Cross-domain expression recognition based on sparse coding and transfer learning
NASA Astrophysics Data System (ADS)
Yang, Yong; Zhang, Weiyi; Huang, Yong
2017-05-01
Traditional facial expression recognition methods usually assume that the training set and the test set are independent and identically distributed. However, in actual expression recognition applications, the conditions of independent and identical distribution are hardly satisfied for the training set and test set because of the difference of light, shade, race and so on. In order to solve this problem and improve the performance of expression recognition in the actual applications, a novel method based on transfer learning and sparse coding is applied to facial expression recognition. First of all, a common primitive model, that is, the dictionary is learnt. Then, based on the idea of transfer learning, the learned primitive pattern is transferred to facial expression and the corresponding feature representation is obtained by sparse coding. The experimental results in CK +, JAFFE and NVIE database shows that the transfer learning based on sparse coding method can effectively improve the expression recognition rate in the cross-domain expression recognition task and is suitable for the practical facial expression recognition applications.
Lee, Jae Myeong; Cho, Young Kwon; Kim, Han Myun; Song, Myung Gyu; Song, Soon-Young; Yeon, Jae Woo; Yoon, Dae Young; Lee, Sam Yeol
2018-03-01
The objective of this study was to conduct a prospective clinical trial evaluating the technical feasibility and short-term clinical outcome of the blind pushing technique for placement of pretrimmed peripherally inserted central catheters (PICCs) through brachial vein access. Patients requiring PICC placement at any of the three participating institutions were prospectively enrolled between January and December 2016. The review boards of all participating institutions approved this study, and informed consent was obtained from all patients. PICC placement was performed using the blind pushing technique and primary brachial vein access. The following data were collected from unified case report forms: access vein, obstacles during PICC advancement, procedure time, and postprocedural complications. During the 12-month study period, 1380 PICCs were placed in 1043 patients. Of these, 1092 PICCs placed in 837 patients were enrolled, with 834 PICCs (76%) and 258 PICCs (34%) placed through brachial vein and nonbrachial vein access, respectively. In both arms, obstacles were most commonly noted in the subclavian veins (n = 220) and axillary veins (n = 94). Successful puncture of the access vein was achieved at first try in 1028 PICCs (94%). The technical success rate was 99%, with 1055 PICCs (97%) placed within 120 seconds of procedure time and 1088 PICCs (99%) having the tip located at the ideal position. Follow-up Doppler ultrasound detected catheter-associated upper extremity deep venous thrombosis (UEDVT) for 18 PICCs in 16 patients and late symptomatic UEDVT for 16 PICCs in 16 patients (3.1%). Catheter-associated UEDVT was noted for 28 PICCs (82%) and 6 PICCs (18%) placed through brachial vein and nonbrachial vein access, respectively. The incidence of obstacles and the procedure time (<120 seconds) differed significantly between brachial vein and nonbrachial vein access (P = .001). There was no statistically significant difference between brachial vein and nonbrachial vein access in the incidence of UEDVT (odds ratio, 0.68; 95% confidence interval, 0.59-3.52; P = .22). The placement of pretrimmed PICCs by the blind pushing technique and primary brachial vein access is technically feasible and may represent an alternative to the conventional PICC placement technique, having low incidences of UEDVT and other complications, with no significant difference in outcomes between brachial vein and nonbrachial vein access. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Cieslak, Kasia P; Huisman, Floor; Bais, Thomas; Bennink, Roelof J; van Lienden, Krijn P; Verheij, Joanne; Besselink, Marc G; Busch, Olivier R C; van Gulik, Thomas M
2017-07-01
Preoperative portal vein embolization is widely used to increase the future remnant liver. Identification of nonresponders to portal vein embolization is essential because these patients may benefit from associating liver partition and portal vein ligation for staged hepatectomy (ALPPS), which induces a more powerful hypertrophy response. 99m Tc-mebrofenin hepatobiliary scintigraphy is a quantitative method for assessment of future remnant liver function with a calculated cutoff value for the prediction of postoperative liver failure. The aim of this study was to analyze future remnant liver function before portal vein embolization to predict sufficient functional hypertrophy response after portal vein embolization. Sixty-three patients who underwent preoperative portal vein embolization and computed tomography imaging were included. Hepatobiliary scintigraphy was performed to determine pre-portal vein embolization and post-portal vein embolization future remnant liver function. Receiver operator characteristic analysis of pre-portal vein embolization future remnant liver function was performed to identify patients who would meet the post-portal vein embolization cutoff value for sufficient function (ie, 2.7%/min/m 2 ). Mean pre-portal vein embolization future remnant liver function was 1.80% ± 0.45%/min/m 2 and increased to 2.89% ± 0.97%/min/m 2 post-portal vein embolization. Receiver operator characteristic analysis in 33 patients who did not receive chemotherapy revealed that a pre-portal vein embolization future remnant liver function of ≥1.72%/min/m 2 was able to identify patients who would meet the safe future remnant liver function cutoff value 3 weeks after portal vein embolization (area under the curve = 0.820). The predictive value was less pronounced in 30 patients treated with neoadjuvant chemotherapy (area under the curve = 0.618). A total of 45 of 63 patients underwent liver resection, of whom 5 of 45 developed postoperative liver failure; 4 of 5 patients had a post-portal vein embolization future remnant liver function below the cutoff value for safe resection. When selecting patients for portal vein embolization, future remnant liver function assessed with hepatobiliary scintigraphy can be used as a predictor of insufficient functional hypertrophy after portal vein embolization, especially in nonchemotherapy patients. These patients are potential candidates for ALPPS. Copyright © 2017 Elsevier Inc. All rights reserved.
Injection of Light Material into an Older Dark Vein
2015-11-11
Light material emplaced within darker vein material is seen in this view of a mineral vein at the "Garden City" site on lower Mount Sharp, Mars. The Mars Hand Lens Imager (MAHLI) on the arm of NASA's Curiosity Mars Rover took the image on April 4, 2015, during the 946th Martian day, or sol, of Curiosity's work on Mars. The area shown is roughly 0.4 inch (1 centimeter) wide. Differences in textures of light-toned veins in the Garden City complex of crisscrossing mineral veins are clues that these veins may result from distinct fluid events. This example shows where injection of light material into a prior dark vein suggests high fluid pressure. Differences in textures of light-toned veins in the Garden City complex of crisscrossing mineral veins are clues that these veins may result from distinct fluid events. This vein's texture shows indications of crystal growth, suggesting that crystallization may have exerted a force for opening the fracture filled by the vein. Different examples are at PIA19925 and PIA19927. Mineral veins often form where fluids move through fractured rocks, depositing minerals in the fractures and affecting chemistry of the surrounding rock. At Garden City, the veins have been more resistant to erosion than the surrounding host rock. The fluid movement through fractures at Garden City occurred later than wet environmental conditions in which the host rock formed, before it hardened and cracked. Malin Space Science Systems, San Diego, built and operates MAHLI. NASA's Jet Propulsion Laboratory, a division of the California Institute of Technology in Pasadena, manages the Mars Science Laboratory Project for the NASA Science Mission Directorate, Washington. JPL designed and built the project's Curiosity rover. http://photojournal.jpl.nasa.gov/catalog/PIA19926
Development of the human infrahepatic inferior caval and azygos venous systems
Hikspoors, Jill P J M; Soffers, Jelly H M; Mekonen, Hayelom K; Cornillie, Pieter; Köhler, S Eleonore; Lamers, Wouter H
2015-01-01
Differences in opinion regarding the development of the infrahepatic inferior caval and azygos venous systems in mammals centre on the contributions of ‘caudal cardinal’, ‘subcardinal’, ‘supracardinal’, ‘medial and lateral sympathetic line’ and ‘sacrocardinal’ veins. The disagreements appear to arise from the use of topographical position rather than developmental origin as criterion to define separate venous systems. We reinvestigated the issue in a closely spaced series of human embryos between 4 and 10 weeks of development. Structures were visualized with the Amira® reconstruction and Cinema4D® remodelling software. The vertebral level and neighbouring structures were used as topographic landmarks. The main results were that the caudal cardinal veins extended caudally from the common cardinal vein between CS11 and CS15, followed by the development of the subcardinal veins as a plexus sprouting ventrally from the caudal cardinal veins. The caudal cardinal veins adapted their course from lateral to medial relative to the laterally expanding lungs, adrenal glands, definitive kidneys, sympathetic trunk and umbilical arteries between CS15 and CS18, and then became interrupted in the part overlaying the regressing mesonephroi (Th12-L3). The caudal part of the left caudal cardinal vein then also regressed. The infrarenal part of the inferior caval vein originated from the right caudal cardinal vein, while the renal part originated from subcardinal veins. The azygos veins developed from the remaining cranial part of the caudal cardinal veins. Our data show that all parts of the inferior caval and azygos venous systems developed directly from the caudal cardinal veins or from a plexus sprouting from these veins. PMID:25496171
Zerweck, Christof; von Hodenberg, Eva; Knittel, Matthias; Zeller, Thomas; Schwarz, Thomas
2014-02-01
Endovenous Laser Ablation (EVLA) is one of the most accepted treatment options for varicose veins. The aim of this study was to investigate the efficacy and safety of the new radial fiber slim (ELVeS-radial-slim kit™) for the 1470 nm diode laser in perforator veins with a 1 month follow-up. Our prospective observational cohort study comprised 69 perforating veins in 55 patients. Ninety percent of all patients were in the CEAP-stage C3-C6. The radial fiber slim was used to occlude the perforating vein and the great or small saphenous vein in the same procedure. The primary efficacy endpoint of the study was ultrasonographically proven elimination of venous reflux in the perforating vein after at least one month. Secondary efficacy and further safety end points after one month were as follows: (1) sonographic exclusion of recanalization of the treated vein segments, (2) deep vein thrombosis (DVT), clinical pulmonary embolism (PE), or superficial vein thrombosis (SVT) as defined by objective testing, (3) death from any cause, (4) persistent clinical complaints such as pain and paresthesia. Follow-up could be completed in all patients. In all treated perforating varicose veins, occlusion with elimination of reflux could be demonstrated immediately after the procedure. After one month 95.6% of the treated veins were still occluded (67/69). During follow-up, we did not diagnose any DVT, PE or SVT in the area related to the treated perforating vein. No patient died. One patient reported paresthesia distally of the puncture site. Endovenous laser treatment of varicose perforating veins with 1470 nm diode laser using the radial fiber slim is effective and safe with low recanalization rates during 1-month follow-up.
Zhang, Mei; Yan, Feng; Huang, Bin; Wu, Zhoupeng; Wen, Xiaorong
2017-11-01
Primary leiomyosarcoma (LMS) of the vein is a rare tumor that arises from the smooth muscle cells of the vessel wall and has an extremely poor prognosis. This tumor can occur in vessels such as the inferior vena cava, great saphenous vein, femoral vein, iliac vein, popliteal vein, and renal vein; the inferior vena cava is the most common site. LMS of the femoral vein can result in edema and pain in the lower extremity; therefore, it is not easy to be differentiated from deep vein thrombosis (DVT). Moreover, virtually no studies have described the ultrasonographic features of LMS of the vein in detail. We present a case of a 55-year-old woman with LMS of the left femoral vein that was misdiagnosed as having deep vein thrombosis (DVT) on initial ultrasonographic examination. The patient began to experience edema and pain in her left leg seven months previously. She was diagnosed as having DVT on initial ultrasonographic examination, but the DVT treatment that she had received for 7 months failed to improve the status of her left lower limb. She subsequently underwent re-examination by means of a multimodal ultrasonographic imaging approach (regular B-mode imaging, color Doppler imaging, pulsed-wave Doppler imaging, contrast-enhanced ultrasonography), which confirmed a diagnosis of LMS. This patient was treated successfully with surgery. This case demonstrates that use of multiple ultrasonographic imaging techniques can be helpful to diagnose LMS accurately. Detection of vasculature in a dilated vein filled with a heterogeneous hypoechoic substance on ultrasonography is a sign of a tumor. The pitfall of misdiagnosing this tumor as DVT is a useful reminder.
Zhang, Mei; Yan, Feng; Huang, Bin; Wu, Zhoupeng; Wen, Xiaorong
2017-01-01
Abstract Rationale: Primary leiomyosarcoma (LMS) of the vein is a rare tumor that arises from the smooth muscle cells of the vessel wall and has an extremely poor prognosis. This tumor can occur in vessels such as the inferior vena cava, great saphenous vein, femoral vein, iliac vein, popliteal vein, and renal vein; the inferior vena cava is the most common site. LMS of the femoral vein can result in edema and pain in the lower extremity; therefore, it is not easy to be differentiated from deep vein thrombosis (DVT). Moreover, virtually no studies have described the ultrasonographic features of LMS of the vein in detail. Patient concerns: We present a case of a 55-year-old woman with LMS of the left femoral vein that was misdiagnosed as having deep vein thrombosis (DVT) on initial ultrasonographic examination. The patient began to experience edema and pain in her left leg seven months previously. She was diagnosed as having DVT on initial ultrasonographic examination, but the DVT treatment that she had received for 7 months failed to improve the status of her left lower limb. Diagnoses: She subsequently underwent re-examination by means of a multimodal ultrasonographic imaging approach (regular B-mode imaging, color Doppler imaging, pulsed-wave Doppler imaging, contrast-enhanced ultrasonography), which confirmed a diagnosis of LMS. Interventions: This patient was treated successfully with surgery. Outcomes: This case demonstrates that use of multiple ultrasonographic imaging techniques can be helpful to diagnose LMS accurately. Detection of vasculature in a dilated vein filled with a heterogeneous hypoechoic substance on ultrasonography is a sign of a tumor. Lessons: The pitfall of misdiagnosing this tumor as DVT is a useful reminder. PMID:29145269
The umbilical and paraumbilical veins of man.
Martin, B F; Tudor, R G
1980-03-01
During its transit through the umbilicus structural changes occur in the thick wall of the extra-abdominal segment of the umbilical vein whereby the components of the intra-abdominal segment acquire an essentially longitudinal direction and become arranged in fibro-elastic and fibro-muscular zones. The vein lumen becomes largely obliterated by asymmetrical proliferation of loose subendothelial conective tissue. The latter forms a new inner zone within which a small segment of the lumen persists in an eccentric position. This residual lumen transmits blood to the portal system from paraumbilical and systemic sources, and is retained in the upper part of the vein, even in old age. A similar process of lumen closure is observed in the ductus venosus. In early childhood the lower third of the vein undergoes breakdown, with fatty infiltration, resulting in its complete division into vascular fibro-elastic strands, and in old age some breakdown occurs in the outermost part of the wall of the upper two thirds. The paraumbilical veins are thick-walled and of similar structure to the umbilical vein. Together they constitute an accessory portal system which is confined between the layers of the falciform ligament and is in communication with the veins of the ventral abdominal wall. The constituents form an ascending series, namely, Burow's veins, the umbilical vein, and Sappey's inferior and superior veins. The main channel of Sappey's inferior veins may be the remnant of the right umbilical vein since it communicates with the right rectus sheath and often communicates directly with the portal system within the right lobe of the liver. The results are of significance in relation to clinical usage of the umbilical vein.
NASA Astrophysics Data System (ADS)
Pilet, S.; Buchs, D.; Cosca, M. A.; Baumgartner, P.
2011-12-01
Petrological studies play a significant role in the debate regarding the origin of intraplate magmas by providing unequivocal constraints about the source(s) composition and melting processes related to basalt formation. Two major hypotheses are currently in debate: first, intraplate magmas are produced at depth (i.e. within the asthenosphere) by low-degrees melting of an enriched peridotitic source in the presence of CO2 [1]; second, alkaline magmas are produced by the melting of metasomatic hydrous veins present within the lithospheric mantle [2]. If the existence of metasomatic veins in the continental lithospheric mantle is well documented, their existence and the mechanism of their formation in an oceanic setting are still mostly unconstrained. Here we report new petrological data demonstrating that metasomatic veins can be produced within the oceanic lithosphere by percolation and differentiation of low-degree melts initially located in the low velocity zone [3]. The existence of metasomatic veins in the oceanic lithosphere is documented by cpx xenocrysts in accreted basaltic sills from northern Costa Rica. New field observations, 40Ar-39Ar radiometric dating, biostratigraphic ages and geochemical analyses indicate that the sills represent a possible, ancient analogue of petit-spot volcanoes produced off Japan by oceanic plate flexure [4]. The cpx xenocrysts are interpreted as a relic of metasomatic veins based on their composition, which is similar to that of cpx from metasomatic veins observed in mantle outcrops and xenoliths. The major and trace element contents of the studied cpx xenocrysts indicate that they crystallized at high pressure in a differentiated liquid. This liquid represents the last stage of a fractional crystallization process that produced early anhydrous cumulates followed by later hydrous cumulates, a mechanism similar to that proposed by Harte et al. [5] for the formation of metasomatic veins in the continental lithosphere. Monte Carlo simulation of this process indicates that the differentiation of low degree melts can produce metasomatic cumulates with a mineralogical and chemical composition suitable to be a source for alkaline rocks observed in an oceanic setting [6]. The presence of low degree melts at the base of the lithosphere has been recently suggested to explain the occurrence of the ubiquitous low seismic velocity zone at the base of the oceanic lithosphere [3]. We propose that tectonic processes such as plate flexure [4] or/and small scale mantle convection [7] can allow these melts to percolate and differentiate across the lithosphere to form metasomatic cumulates (i.e. veins). Such cumulates are likely to represent a potential source of alkaline rocks observed in intraplate ocean volcanoes, especially those produced by low volumes of magma. [1] Dasgupta et al. (2007) J. of Petrol. 48, 2093; [2] Pilet et al. (2008) Science 320, 916; [3] Kawakatsu et al. (2009) Science 324, 499; [4] Hirano et al. (2006) Science 313, 1426 ; [5] Harte et al. (1993) Phil. Trans. Royal Soc. of London, Series A 342, 1; [6] Pilet et al. (2011) J. of Petrol. doi:10.1093/petrology/egr007; [7] Ballmer et al. (2009) G3 doi:10.1029/2009GC002386.
Shan, Hong; Xiao, Xiang-Sheng; Huang, Ming-Sheng; Ouyang, Qiang; Jiang, Zai-Bo
2005-06-07
To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated. Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3+/-4.7) cm H(2)O to (18.0+/-1.9) cm H(2)O. The portal blood flow restored and the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.
New therapeutic possibilities for vein graft disease in the post-edifoligide era.
Cai, Xinjiang; Freedman, Neil J
2006-07-01
Vein graft neointimal hyperplasia involves proliferation and migration of vascular smooth muscle cells into the vessel intima, and ultimately engenders accelerated atherosclerosis and vein graft failure. Since a myriad of stimuli provoke smooth muscle cell proliferation, molecular therapies for vein graft disease have targeted mechanisms fundamental to all cell proliferation - the 'cell-cycle' machinery. Preclinically, the most successful of these therapies has been edifoligide (E2F decoy), a double-stranded oligodeoxynucleotide that binds to the transcription factor known as E2F. Recently, PRoject of Ex vivo vein GRaft Engineering via Transfection (PREVENT) III and IV demonstrated that edifoligide failed to benefit human vein grafts employed to treat lower-extremity ischemia and coronary heart disease, respectively. The clinical failure of edifoligide calls into question previous models of vein graft disease and lends credence to recent animal studies demonstrating that vein graft arterialization substantially involves the immigration into the vein graft of a variety of vascular progenitor cells. Future vein graft disease therapies will likely target not only proliferation of graft-intrinsic cells, but also immigration of graft-extrinsic cells.
Material recognition based on thermal cues: Mechanisms and applications.
Ho, Hsin-Ni
2018-01-01
Some materials feel colder to the touch than others, and we can use this difference in perceived coldness for material recognition. This review focuses on the mechanisms underlying material recognition based on thermal cues. It provides an overview of the physical, perceptual, and cognitive processes involved in material recognition. It also describes engineering domains in which material recognition based on thermal cues have been applied. This includes haptic interfaces that seek to reproduce the sensations associated with contact in virtual environments and tactile sensors aim for automatic material recognition. The review concludes by considering the contributions of this line of research in both science and engineering.
Material recognition based on thermal cues: Mechanisms and applications
Ho, Hsin-Ni
2018-01-01
ABSTRACT Some materials feel colder to the touch than others, and we can use this difference in perceived coldness for material recognition. This review focuses on the mechanisms underlying material recognition based on thermal cues. It provides an overview of the physical, perceptual, and cognitive processes involved in material recognition. It also describes engineering domains in which material recognition based on thermal cues have been applied. This includes haptic interfaces that seek to reproduce the sensations associated with contact in virtual environments and tactile sensors aim for automatic material recognition. The review concludes by considering the contributions of this line of research in both science and engineering. PMID:29687043
el-Sanadiki, M N; Cross, K S; Murray, J J; Schuman, R W; Mikat, E; McCann, R L; Hagen, P O
1990-01-01
Recent studies have shown that calcium antagonists exert an antiatherogenic effect in animals fed cholesterol. Vein graft intimal hyperplasia is believed to be an early event in atherosclerotic lesion formation, which is a significant cause of graft failure. Altered vasoreactivity has also been postulated in the etiology of vein graft failure. Therefore this study examined the effect of verapamil treatment on the development of intimal hyperplasia and the vasoreactivity of experimental vein bypass grafts. The right external jugular vein was grafted into the right carotid artery of 30 male New Zealand white rabbits fed normal rabbit chow. The left external jugular vein was used as the control vein. Fifteen animals received verapamil (1.25 mg/day for 28 days) via the femoral vein by means of an osmotic pump. In 15 control animals the pump contained saline. Plasma verapamil concentration was 50.9 +/- 13.2 ng/mL (x +/- SEM), a dose that showed no effect on either blood pressure, total serum cholesterol, or in vitro platelet aggregation to ADP. Fourteen of fifteen grafts were patent in each group, for a patency rate of 93%. Histologic examination using computer morphometry showed significant reduction of intimal hyperplasia at the proximal, middle, and distal graft segments (p less than 0.05). In addition in vitro isometric tension studies of the vein grafts and control veins showed that verapamil causes enhanced reactivity of both vein grafts and control veins in response to norepinephrine and histamine (p less than 0.05). Reactivity of vein grafts to serotonin was unaltered. While none of the normal veins in the control group responded to serotonin, normal veins treated with verapamil contracted readily in response to serotonin. Endothelial-dependent relaxation to acetylcholine was absent in both control and verapamil-treated vein grafts, while normal veins from both groups responded to the same extent to acetylcholine. Because we could not demonstrate any difference in platelet or endothelium function between untreated and verapamil-treated animals, we examined the direct effect of verapamil on smooth muscle. Verapamil significantly inhibited [3H]-thymidine incorporation into DNA in vascular smooth muscle cells in culture in a dose-dependent manner. Verapamil treatment significantly reduces intimal hyperplasia in experimental vein grafts and inhibits smooth muscle cell proliferation in culture. Furthermore the enhanced reactivity to norepinephrine and histamine in the verapamil-treated vessels has no detrimental effect on the patency rate at 4 weeks. Thus by inhibiting intimal hyperplasia, calcium antagonists may improve the long-term patency of vein bypass grafts. Images Figs. 1A-C. PMID:2363608
Score-Level Fusion of Phase-Based and Feature-Based Fingerprint Matching Algorithms
NASA Astrophysics Data System (ADS)
Ito, Koichi; Morita, Ayumi; Aoki, Takafumi; Nakajima, Hiroshi; Kobayashi, Koji; Higuchi, Tatsuo
This paper proposes an efficient fingerprint recognition algorithm combining phase-based image matching and feature-based matching. In our previous work, we have already proposed an efficient fingerprint recognition algorithm using Phase-Only Correlation (POC), and developed commercial fingerprint verification units for access control applications. The use of Fourier phase information of fingerprint images makes it possible to achieve robust recognition for weakly impressed, low-quality fingerprint images. This paper presents an idea of improving the performance of POC-based fingerprint matching by combining it with feature-based matching, where feature-based matching is introduced in order to improve recognition efficiency for images with nonlinear distortion. Experimental evaluation using two different types of fingerprint image databases demonstrates efficient recognition performance of the combination of the POC-based algorithm and the feature-based algorithm.
Speaker-independent phoneme recognition with a binaural auditory image model
NASA Astrophysics Data System (ADS)
Francis, Keith Ivan
1997-09-01
This dissertation presents phoneme recognition techniques based on a binaural fusion of outputs of the auditory image model and subsequent azimuth-selective phoneme recognition in a noisy environment. Background information concerning speech variations, phoneme recognition, current binaural fusion techniques and auditory modeling issues is explained. The research is constrained to sources in the frontal azimuthal plane of a simulated listener. A new method based on coincidence detection of neural activity patterns from the auditory image model of Patterson is used for azimuth-selective phoneme recognition. The method is tested in various levels of noise and the results are reported in contrast to binaural fusion methods based on various forms of correlation to demonstrate the potential of coincidence- based binaural phoneme recognition. This method overcomes smearing of fine speech detail typical of correlation based methods. Nevertheless, coincidence is able to measure similarity of left and right inputs and fuse them into useful feature vectors for phoneme recognition in noise.
Hwang, J J; Lin, J M; Hsu, K L; Lai, L P; Tseng, Y Z; Lee, Y T; Lien, W P
1999-01-01
To evaluate the correlation of the flow patterns of the four pulmonary veins as assessed by transesophageal echocardiography and the influence of significant mitral regurgitation on this correlation. Eighty-eight patients with normal sinus rhythm and variable underlying cardiovascular diseases underwent transthoracic and transesophageal echocardiographic studies. Doppler flow of the four pulmonary veins could not be adequately interpreted in 19 patients (22%). The left atrial dimension of these patients was significantly larger than that of the patients with complete study of the flow in the four pulmonary veins (49 +/- 6 vs. 43 +/- 7 mm; p < 0.05). Of the 69 patients with complete evaluation of the four pulmonary veins, 48 patients without significant mitral regurgitation were analyzed as group A, and the remaining 21 patients as group B. The peak systolic and diastolic forward flow velocities of the four pulmonary veins were measured and the ratio of peak systolic (S) to diastolic (D) flow velocity was calculated. Group A had a significantly larger S/D ratio in all four pulmonary veins than group B (p < 0.05 in each pulmonary vein measurement). There was good correlation of the flow pattern represented as S/D ratio between left upper and lower pulmonary veins (r = 0.90) and between right upper and lower pulmonary veins (r = 0.89) in group A. The correlation of the flow pattern among the four pulmonary veins deteriorated in group B. Pulmonary veins on the same side share rather similar flow patterns in comparison with pulmonary veins on the opposite sides. The correlation of flow patterns among the four pulmonary veins is good in subjects without significant mitral regurgitation, but it worsens in patients with significant mitral regurgitation. Therefore, cautious interpretation of flow patterns of the four pulmonary veins in patients with significant regurgitation is indicated for grading the severity of mitral regurgitation.
Squara, Fabien; Tomi, Julien; Scarlatti, Didier; Theodore, Guillaume; Moceri, Pamela; Ferrari, Emile
2017-12-01
Axillary vein access for pacemaker implantation is uncommon in many centres because of the lack of training in this technique. We assessed whether the introduction of the axillary vein technique was safe and efficient as compared with cephalic vein access, in a centre where no operators had any previous experience in axillary vein puncture. Patients undergoing pacemaker implantation were randomized to axillary or cephalic vein access. All three operators had no experience nor training in axillary vein puncture, and self-learned the technique by reading a published review. Axillary vein puncture was fluoroscopy-guided without contrast venography. Cephalic access was performed by dissection of delto-pectoral groove. Venous access success, venous access duration (from skin incision to guidewire or lead in superior vena cava), procedure duration, X-ray exposure, and peri-procedural (1 month) complications were recorded. results We randomized 74 consecutive patients to axillary (n = 37) or cephalic vein access (n = 37). Axillary vein was successfully accessed in 30/37 (81.1%) patients vs. 28/37 (75.7%) of cephalic veins (P = 0.57). Venous access time was shorter in axillary group than in cephalic group [5.7 (4.4-8.3) vs. 12.2 (10.5-14.8) min, P < 0.001], as well as procedure duration [34.8 (30.6-38.4) vs. 42.0 (39.1-46.6) min, P = 0.043]. X-ray exposure and peri-procedural overall complications were comparable in both groups. Axillary puncture was safe and faster than cephalic access even for the five first procedures performed by each operator. Self-taught axillary vein puncture for pacemaker implantation seems immediately safe and faster than cephalic vein access, when performed by electrophysiologists trained to pacemaker implantation but not to axillary vein puncture. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.
Phenotypic heterogeneity in the endothelium of the human vortex vein system.
Yu, Paula K; Tan, Priscilla E Z; Cringle, Stephen J; McAllister, Ian L; Yu, Dao-Yi
2013-10-01
The vortex vein system is the drainage pathway for the choroidal circulation and serves an important function in the effective drainage of the exceptionally high blood flow from the choroidal circulation. As there are only 4-6 vortex veins, a large volume of blood must be drained from many choroidal veins into each individual vortex vein. The vortex vein system must also cope with passing through tissues of different rigidity and significant pressure gradient as it transverses from the intrao-cular to the extra-ocular compartments. However, little is known about how the vortex vein system works under such complex situations in both physiological and pathological condition. Endothelial cells play a vital role in other vascular systems, but they have not been studied in detail in the vortex vein system. The purpose of this study is to characterise the intracellular structures and morphology in both the intra-and extra-ocular regions of the human vortex vein system. We hypothesise the presence of endothelial phenotypic heterogeneity through the vortex vein system. The inferior temporal vortex vein system from human donor eyes were obtained and studied histologically using confocal microscopy. The f-actin cytoskeleton and nuclei were labelled using Alexa Fluor conjugated Phalloidin and YO-PRO-1. Eight regions of the vortex vein system were examined with the venous endothelium studied in detail with quantitative data obtained for endothelial cell and nuclei size and shape. Significant endothelial phenotypic heterogeneity was found throughout the vortex vein system with the most obvious differences observed between the ampulla and its downstream regions. Variation in the distribution pattern of smooth muscle cells, in particular the absence of smooth muscle cells around the ampulla, was noted. Our results suggest the presence of significantly different haemodynamic forces in different regions of the vortex vein system and indicate that the vortex vein system may play important roles in regulation of the choroidal circulation. Copyright © 2013 Elsevier Ltd. All rights reserved.
Stewart, Jared J; Polutchko, Stephanie K; Demmig-Adams, Barbara; Adams, William W
2018-01-01
An Arabidopsis thaliana accession with naturally low vein density, Eifel-5 (Ei-5), was compared to Columbia-0 (Col-0) with respect to rosette growth, foliar vein architecture, photosynthesis, and transpiration. In addition to having to a lower vein density, Ei-5 grew more slowly, with significantly lower rates of rosette expansion, but had similar capacities for photosynthetic oxygen evolution on a leaf area basis compared to Col-0. The individual foliar minor veins were larger in Ei-5, with a greater number of vascular cells per vein, compared to Col-0. This compensation for low vein density resulted in similar values for the product of vein density × phloem cell number per minor vein in Ei-5 and Col-0, which suggests a similar capacity for foliar sugar export to support similar photosynthetic capacities per unit leaf area. In contrast, the product of vein density × xylem cell number per minor vein was significantly greater in Ei-5 compared to Col-0, and was associated not only with a higher ratio of water-transporting tracheary elements versus sugar-transporting sieve elements but also significantly higher foliar transpiration rates per leaf area in Ei-5. In contrast, previous studies in other systems had reported higher ratios of tracheary to sieve elements and higher transpiration rate to be associated with higher - rather than lower - vein densities. The Ei-5 accession thus further underscores the plasticity of the foliar vasculature by illustrating an example where a higher ratio of tracheary to sieve elements is associated with a lower vein density. Establishment of the Ei-5 accession, with a low vein density but an apparent overcapacity for water flux through the foliar xylem network, may have been facilitated by a higher level of precipitation in its habitat of origin compared to that of the Col-0 accession.
Patterning of leaf vein networks by convergent auxin transport pathways.
Sawchuk, Megan G; Edgar, Alexander; Scarpella, Enrico
2013-01-01
The formation of leaf vein patterns has fascinated biologists for centuries. Transport of the plant signal auxin has long been implicated in vein patterning, but molecular details have remained unclear. Varied evidence suggests a central role for the plasma-membrane (PM)-localized PIN-FORMED1 (PIN1) intercellular auxin transporter of Arabidopsis thaliana in auxin-transport-dependent vein patterning. However, in contrast to the severe vein-pattern defects induced by auxin transport inhibitors, pin1 mutant leaves have only mild vein-pattern defects. These defects have been interpreted as evidence of redundancy between PIN1 and the other four PM-localized PIN proteins in vein patterning, redundancy that underlies many developmental processes. By contrast, we show here that vein patterning in the Arabidopsis leaf is controlled by two distinct and convergent auxin-transport pathways: intercellular auxin transport mediated by PM-localized PIN1 and intracellular auxin transport mediated by the evolutionarily older, endoplasmic-reticulum-localized PIN6, PIN8, and PIN5. PIN6 and PIN8 are expressed, as PIN1 and PIN5, at sites of vein formation. pin6 synthetically enhances pin1 vein-pattern defects, and pin8 quantitatively enhances pin1pin6 vein-pattern defects. Function of PIN6 is necessary, redundantly with that of PIN8, and sufficient to control auxin response levels, PIN1 expression, and vein network formation; and the vein pattern defects induced by ectopic PIN6 expression are mimicked by ectopic PIN8 expression. Finally, vein patterning functions of PIN6 and PIN8 are antagonized by PIN5 function. Our data define a new level of control of vein patterning, one with repercussions on other patterning processes in the plant, and suggest a mechanism to select cell files specialized for vascular function that predates evolution of PM-localized PIN proteins.
Xu, Xiang-Ru Shannon; Gantz, Valentino Matteo; Siomava, Natalia; Bier, Ethan
2017-12-23
The knirps ( kni ) locus encodes transcription factors required for induction of the L2 wing vein in Drosophila . Here, we employ diverse CRISPR/Cas9 genome editing tools to generate a series of targeted lesions within the endogenous cis-regulatory module (CRM) required for kni expression in the L2 vein primordium. Phenotypic analysis of these ' in locus ' mutations based on both expression of Kni protein and adult wing phenotypes, reveals novel unexpected features of L2-CRM function including evidence for a chromosome pairing-dependent process that promotes transcription. We also demonstrate that self-propagating active genetic elements (CopyCat elements) can efficiently delete and replace the L2-CRM with orthologous sequences from other divergent fly species. Wing vein phenotypes resulting from these trans-species enhancer replacements parallel features of the respective donor fly species. This highly sensitive phenotypic readout of enhancer function in a native genomic context reveals novel features of CRM function undetected by traditional reporter gene analysis. © 2017, Xu et al.
Siomava, Natalia
2017-01-01
The knirps (kni) locus encodes transcription factors required for induction of the L2 wing vein in Drosophila. Here, we employ diverse CRISPR/Cas9 genome editing tools to generate a series of targeted lesions within the endogenous cis-regulatory module (CRM) required for kni expression in the L2 vein primordium. Phenotypic analysis of these ‘in locus’ mutations based on both expression of Kni protein and adult wing phenotypes, reveals novel unexpected features of L2-CRM function including evidence for a chromosome pairing-dependent process that promotes transcription. We also demonstrate that self-propagating active genetic elements (CopyCat elements) can efficiently delete and replace the L2-CRM with orthologous sequences from other divergent fly species. Wing vein phenotypes resulting from these trans-species enhancer replacements parallel features of the respective donor fly species. This highly sensitive phenotypic readout of enhancer function in a native genomic context reveals novel features of CRM function undetected by traditional reporter gene analysis. PMID:29274230
Portal vein thrombosis in paroxysmal nocturnal haemoglobinuria.
Tomizuka, H; Hatake, K; Kitagawa, S; Yamashita, K; Arai, H; Miura, Y
1999-01-01
A 28-year-old man was hospitalized with nausea, vomiting, abdominal pain and low-grade fever. He had a 6-month history of paroxysmal nocturnal haemoglobinuria (PNH), and laboratory data showed anaemia and liver dysfunction. An abdominal ultrasonography showed ascites and portal vein thrombosis. After receiving antithrombotic treatment, the portal vein thrombosis did not extend. Portal vein thrombosis is very rare but should be considered when we encounter liver dysfunction associated with PNH as well as hepatic vein thrombosis. Ultrasonography is very useful in detecting portal vein thrombosis and facilitating early diagnosis. Warfarin is very effective in preventing exacerbation of portal vein thrombosis in PNH.
Metamorphism and gold mineralization in the Blue Ridge, Southernmost Appalachians
Stowell, H.H.; Lesher, C.M.; Green, N.L.; Sha, P.; Guthrie, G.M.; Sinha, A.K.
1996-01-01
Lode gold mineralization in the Blue Ridge of the southernmost Appalachians is hosted by metavolcanic rocks (e.g., Anna Howe mine, AL; Royal Vindicator mine, GA), metaplutonic rocks (e.g., Hog Mountain mine, AL), and metasedimentary rocks (e.g., Lowe, Tallapoosa, and Jones Vein mines, AL). Most gold occurs in synkinematic quartz ?? plagioclase ?? pyrite ?? pyrrhotite ?? chlorite veins localized along polydeformational faults that juxtapose rocks with significantly different peak metamorphic mineral assemblages. Mineralogy, chemistry, and O and H isotope studies suggest that the three types of host rocks have undergone differing amounts and types of alteration during mineralization. Limited wall-rock alteration in metavolcanic- and metasediment-hosted deposits, and relatively extensive wall-rock alteration in granitoid-hosted deposits, suggests that most deposits formed from fluids that were close to equilibrium with metavolcanic and metasedimentary rocks. Stable isotope compositions of the fluids calculated from vein minerals and vein selvages are consistent with a predominantly metasedimentary fluid source, but vary from deposit to deposit (-22 to -47??? ??D, 4-5??? ??18O, and 5-7??? ??34S at Anna Howe and Royal Vindicator; -48 to -50??? ??D, 9-13??? ??18O, and ca. 19??? ??34S at Lowe and Jones Vein; and -22 to -23??? ??D, 8-11??? ??18O, 9-10??? ??34S, and -6 ??13C at Hog Mountain). Silicate mineral thermobarometry of vein, vein selvage, and wall-rock mineral assemblages indicate that mineralization and regional metamorphism occured at greenschist to amphibolite facies (480?? ?? 75??C at Anna Howe, 535?? ?? 50??C at 6.4 ?? 1 kbars at Lowe, 530?? ?? 50??C at 6.9 ?? 1 kbars at Tallapoosa, and 460?? ?? 50??C at 5.5 ?? 1 kbars at Hog Mountain). Oxygen isotope fractionation between vein minerals and selvage minerals consistently records equilibration temperatures that are similar to or slightly lower than those estimated from silicate thermometry. Auriferous veins contain numerous fluid inclusions that were emplaced in several stages and can be subdivided into five compositional types based on salt and CO2 concentrations. Fluid inclusion isochores for early formed inclusions from these veins intercept the pressure and temperature conditions estimated from silicate mineral thermobarometry and stable isotope thermometry, and are compatible with entrapment at those conditions. These fluids exhibit significant variation in salinity (XNaClequiv = 0.0-0.2) and CO2 (XCO2 = 0.0-0.2), suggesting variation in fluid-wall-rock interaction that accompanied gold deposition during declining temperatures. Less abundant and later fluids within the veins are dominantly CO2. The association of gold mineralization with structurally controlled concordant and discordant quartz sulfide veins, and the temperatures and pressures of wall-rock alteration and regional metamorphism indicate that the present distribution of gold is a result of metamorphism during progressive D2-D3 deformation. Isotopic data for alteration envelopes date this event as Alleghanian: 279 ?? 14 Ma (K-Ar whole rock) and 343 ?? 18 Ma (K-Ar biotite) at Lowe; and 315 ?? 18 Ma (Rb-Sr whole-rock isochron; 87Sr/86Sr, = 0.7061 ?? 0.0008) and 294 ?? 16 Ma (K-Ar whole-rock) at Hog Mountain. Available data are compatible with development of the lodes during early Alleghanian overthrusting of allochthons over sedimentary rocks of the autochthonous North American margin. The implication is that the fluids were derived from metasedimentary and/or metavolcanic formations in the lower parts of the crystalline thrust stack (or possibly from underlying autochthonous sedimentary formations), ascended along permeable fault zones, and were emplaced as veins into dilatent areas in and adjacent to the fault zones.
An Hybrid 2-Stage Technique to Treat a Post-Traumatic Internal Carotid-Jugular Fistula.
Massara, Mafalda; Barillà, David; De Caridi, Giovanni; Serra, Raffaele; Volpe, Alberto; Cutrupi, Andrea; Alberti, Antonino; Volpe, Pietro
2017-01-01
Penetrating wounds of the neck involving the carotid arteries can lead to 2 possible and important late sequelae: pseudoaneurysm formation and arteriovenous fistula (AVF), if an artery and the adjacent jugular vein are simultaneously lacerated. Traumatic AVF of the neck are rare complications and if untreated may cause congestive heart failure, cerebral ischemia, thromboembolism, or even rupture complications. Current treatment options for carotid-jugular AVF include operative repair, detachable balloon, coiling, or stenting. We present a hybrid 2-stage technique to treat an internal carotid-jugular vein fistula in a young woman, based first on carotid stenting to reduce the bleeding and reestablish an adequate cerebral perfusion, followed by stent removal and safe vessels surgical reconstruction through carotid-to-carotid bypass and vein repair. Copyright © 2016 Elsevier Inc. All rights reserved.
GRANITE FIORDS WILDERNESS STUDY AREA, ALASKA.
Berg, Henry C.; Pittman, Tom L.
1984-01-01
Mineral surveys of the Granite Fiords Wilderness study area revealed areas with probable and substantiated mineral-resource potential. In the northeastern sector, areas of probable and substantiated resource potential for gold, sivler, and base metals in small, locally high grade vein and disseminated deposits occur in recrystallized Mesozoic volcanic, sedimentary, and intrusive rocks. In the central part, areas of probable resource potential for gold, silver, copper, and zinc in disseminated and locally massive sulfide deposits occur in undated pelitic paragneiss roof pendants. A molybdenite-bearing quartz vein has been prospected in western Granite Fiords, and molybdenum also occurs along with other metals in veins in the northeastern sector and in geochemical samples collected from areas where there is probable resource potential for low-grade porphyry molybdenum deposits in several Cenozoic plutons. No energy resource potential was identified in the course of this study.
Walker, B.M.; Ben Talib, Majed; El Komi, Mohamed; Hussain, M.A.; Christian, R.P.
1990-01-01
Quartz veins intersected by drill holes are surrounded by mylonite schist. Quartz and carbonate veins less than 5 mm thick are boudined, whereas thick quartz veins (£ 1.2 m) have disrupted and brecciated margins; mylonitized country rock envelops quartz-vein fragments. Sulfide mineralization associated with vein formation predates this rock-deformation event. Contemporaneous brittle and ductile deformation of quartz veins and country rocks occurred during the Nabitah orogeny. Supergene gold enrichment took place much later.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mert, Murat; Saltik, Levent; Gunay, Ilhan
2004-08-15
An 8-month old girl was presented with superior caval vein syndrome early after cardiac surgery. Angiography showed severe stenosis of the superior caval vein with 50 mmHg pressure gradient. Following balloon angioplasty, the pressure gradient was reduced to 7 mmHg with some residual stenosis of the superior caval vein. When the patient was reevaluated 5 months after the procedure, angiography revealed a normal diameter of the superior caval vein without a pressure gradient.
Appearance-based face recognition and light-fields.
Gross, Ralph; Matthews, Iain; Baker, Simon
2004-04-01
Arguably the most important decision to be made when developing an object recognition algorithm is selecting the scene measurements or features on which to base the algorithm. In appearance-based object recognition, the features are chosen to be the pixel intensity values in an image of the object. These pixel intensities correspond directly to the radiance of light emitted from the object along certain rays in space. The set of all such radiance values over all possible rays is known as the plenoptic function or light-field. In this paper, we develop a theory of appearance-based object recognition from light-fields. This theory leads directly to an algorithm for face recognition across pose that uses as many images of the face as are available, from one upwards. All of the pixels, whichever image they come from, are treated equally and used to estimate the (eigen) light-field of the object. The eigen light-field is then used as the set of features on which to base recognition, analogously to how the pixel intensities are used in appearance-based face and object recognition.
NASA Astrophysics Data System (ADS)
Jajamovich, Guido H.; Pamulapati, Vivek; Alam, Shoaib; Mehari, Alem; Kato, Gregory J.; Wood, Bradford J.; Linguraru, Marius George
2012-03-01
Pulmonary hypertension is a common cause of death among patients with sickle cell disease. This study investigates the use of pulmonary vein analysis to assist the diagnosis of pulmonary hypertension non-invasively with CT-Angiography images. The characterization of the pulmonary veins from CT presents two main challenges. Firstly, the number of pulmonary veins is unknown a priori and secondly, the contrast material is degraded when reaching the pulmonary veins, making the edges of these vessels to appear faint. Each image is first denoised and a fast marching approach is used to segment the left atrium and pulmonary veins. Afterward, a geodesic active contour is employed to isolate the left atrium. A thinning technique is then used to extract the skeleton of the atrium and the veins. The locations of the pulmonary veins ostia are determined by the intersection of the skeleton and the contour of the atrium. The diameters of the pulmonary veins are measured in each vein at fixed distances from the corresponding ostium, and for each distance, the sum of the diameters of all the veins is computed. These indicators are shown to be significantly larger in sickle-cell patients with pulmonary hypertension as compared to controls (p-values < 0.01).
Bundle sheath lignification mediates the linkage of leaf hydraulics and venation.
Ohtsuka, Akihiro; Sack, Lawren; Taneda, Haruhiko
2018-02-01
The lignification of the leaf vein bundle sheath (BS) has been observed in many species and would reduce conductance from xylem to mesophyll. We hypothesized that lignification of the BS in lower-order veins would provide benefits for water delivery through the vein hierarchy but that the lignification of higher-order veins would limit transport capacity from xylem to mesophyll and leaf hydraulic conductance (K leaf ). We further hypothesized that BS lignification would mediate the relationship of K leaf to vein length per area. We analysed the dependence of K leaf , and its light response, on the lignification of the BS across vein orders for 11 angiosperm tree species. Eight of 11 species had lignin deposits in the BS of the midrib, and two species additionally only in their secondary veins, and for six species up to their minor veins. Species with lignification of minor veins had a lower hydraulic conductance of xylem and outside-xylem pathways and lower K leaf . K leaf could be strongly predicted by vein length per area and highest lignified vein order (R 2 = .69). The light-response of K leaf was statistically independent of BS lignification. The lignification of the BS is an important determinant of species variation in leaf and thus whole plant water transport. © 2017 John Wiley & Sons Ltd.
2014-01-01
Background Subcutaneous veins localization is usually performed manually by medical staff to find suitable vein to insert catheter for medication delivery or blood sample function. The rule of thumb is to find large and straight enough vein for the medication to flow inside of the selected blood vessel without any obstruction. The problem of peripheral difficult venous access arises when patient’s veins are not visible due to any reason like dark skin tone, presence of hair, high body fat or dehydrated condition, etc. Methods To enhance the visibility of veins, near infrared imaging systems is used to assist medical staff in veins localization process. Optimum illumination is crucial to obtain a better image contrast and quality, taking into consideration the limited power and space on portable imaging systems. In this work a hyperspectral image quality assessment is done to get the optimum range of illumination for venous imaging system. A database of hyperspectral images from 80 subjects has been created and subjects were divided in to four different classes on the basis of their skin tone. In this paper the results of hyper spectral image analyses are presented in function of the skin tone of patients. For each patient, four mean images were constructed by taking mean with a spectral span of 50 nm within near infrared range, i.e. 750–950 nm. Statistical quality measures were used to analyse these images. Conclusion It is concluded that the wavelength range of 800 to 850 nm serve as the optimum illumination range to get best near infrared venous image quality for each type of skin tone. PMID:25087016
Amin, Elham E; van Kuijk, Sander M J; Joore, Manuela A; Prandoni, Paolo; Cate, Hugo Ten; Cate-Hoek, Arina J Ten
2018-06-04
Post-thrombotic syndrome (PTS) is a common chronic consequence of deep vein thrombosis that affects the quality of life and is associated with substantial costs. In clinical practice, it is not possible to predict the individual patient risk. We develop and validate a practical two-step prediction tool for PTS in the acute and sub-acute phase of deep vein thrombosis. Multivariable regression modelling with data from two prospective cohorts in which 479 (derivation) and 1,107 (validation) consecutive patients with objectively confirmed deep vein thrombosis of the leg, from thrombosis outpatient clinic of Maastricht University Medical Centre, the Netherlands (derivation) and Padua University hospital in Italy (validation), were included. PTS was defined as a Villalta score of ≥ 5 at least 6 months after acute thrombosis. Variables in the baseline model in the acute phase were: age, body mass index, sex, varicose veins, history of venous thrombosis, smoking status, provoked thrombosis and thrombus location. For the secondary model, the additional variable was residual vein obstruction. Optimism-corrected area under the receiver operating characteristic curves (AUCs) were 0.71 for the baseline model and 0.60 for the secondary model. Calibration plots showed well-calibrated predictions. External validation of the derived clinical risk scores was successful: AUC, 0.66 (95% confidence interval [CI], 0.63-0.70) and 0.64 (95% CI, 0.60-0.69). Individual risk for PTS in the acute phase of deep vein thrombosis can be predicted based on readily accessible baseline clinical and demographic characteristics. The individual risk in the sub-acute phase can be predicted with limited additional clinical characteristics. Schattauer GmbH Stuttgart.
Onishi, Natsuko; Kataoka, Masako; Kanao, Shotaro; Sagawa, Hajime; Iima, Mami; Nickel, Marcel Dominik; Toi, Masakazu; Togashi, Kaori
2018-01-01
To evaluate the feasibility of ultrafast dynamic contrast-enhanced (UF-DCE) magnetic resonance imaging (MRI) with compressed sensing (CS) for the separate identification of breast arteries/veins and perform temporal evaluations of breast arteries and veins with a focus on the association with ipsilateral cancers. Our Institutional Review Board approved this study with retrospective design. Twenty-five female patients who underwent UF-DCE MRI at 3T were included. UF-DCE MRI consisting of 20 continuous frames was acquired using a prototype 3D gradient-echo volumetric interpolated breath-hold sequence including a CS reconstruction: temporal resolution, 3.65 sec/frame; spatial resolution, 0.9 × 1.3 × 2.5 mm. Two readers analyzed 19 maximum intensity projection images reconstructed from subtracted images, separately identified breast arteries/veins and the earliest frame in which they were respectively visualized, and calculated the time interval between arterial and venous visualization (A-V interval) for each breast. In total, 49 breasts including 31 lesions (breast cancer, 16; benign lesion, 15) were identified. In 39 of the 49 breasts (breasts with cancers, 16; breasts with benign lesions, 10; breasts with no lesions, 13), both breast arteries and veins were separately identified. The A-V intervals for breasts with cancers were significantly shorter than those for breasts with benign lesions (P = 0.043) and no lesions (P = 0.007). UF-DCE MRI using CS enables the separate identification of breast arteries/veins. Temporal evaluations calculating the time interval between arterial and venous visualization might be helpful in the differentiation of ipsilateral breast cancers from benign lesions. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:97-104. © 2017 International Society for Magnetic Resonance in Medicine.
Ibukuro, Kenji; Takeguchi, Takaya; Fukuda, Hozumi; Abe, Shoko; Tobe, Kimiko
2016-11-01
To analyze the vascular structure of the liver in patients with a right-sided round ligament. We reviewed 16 patients with a right-sided round ligament and 3 polysplenia and situs inversus patients with a left-sided round ligament who underwent multidetector row CT with contrast media. The patient population consisted of 13 men and 6 women (mean 62 years). We analyzed the axial and volume-rendered images for the location of the round ligament, gallbladder, portal veins, hepatic veins, and hepatic artery. The following imaging findings for the patients with polysplenia and situs inversus were horizontally reversed. The prevalence of a right-sided round ligament with and without polysplenia was 75 and 0.11 %, respectively. The gallbladder was located to the right, below, and left of the round ligament in 27.7, 38.8 and 33.3 %, respectively. Independent branching of the right posterior portal vein was noted in 57.8 %. PV4 was difficult to identify in 36.8 %. The middle hepatic vein was located to the left of the round ligament. Two branching patterns for the lateral and medial branches of the right anterior hepatic artery were noted: the common (44.4 %) and separated types (55.5 %). Both of the right anterior hepatic artery and portal vein ramified into two segments; the lateral segment with many branches and the medial segment with a few branches. The right-sided round ligament divided the right anterior section into the lateral and medial segments based on the portal vein and hepatic artery anatomy.
Park, Chung Hyun; Hong, Namki; Han, Kichang; Kang, Sang Wook; Lee, Cho Rok; Park, Sungha; Rhee, Yumie
2018-05-04
Adrenal venous sampling (AVS) is a gold standard for subtype classification of primary aldosteronism (PA). However, this procedure has a high failure rate because of the anatomical difficulties in accessing the right adrenal vein. We investigated whether C-arm computed tomography-assisted AVS (C-AVS) could improve the success rate of adrenal sampling. A total of 156 patients, diagnosed with PA who underwent AVS from May 2004 through April 2017, were included. Based on the medical records, we retrospectively compared the overall, left, and right catheterization success rates of adrenal veins during the periods without C-AVS (2004 to 2010, n=32) and with C-AVS (2011 to 2016, n=134). The primary outcome was adequate bilateral sampling defined as a selectivity index (SI) >5. With C-AVS, the rates of adequate bilateral AVS increased from 40.6% to 88.7% (P<0.001), with substantial decreases in failure rates (43.7% to 0.8%, P<0.001). There were significant increases in adequate sampling rates from right (43.7% to 91.9%, P<0.001) and left adrenal veins (53.1% to 95.9%, P<0.001) as well as decreases in catheterization failure from right adrenal vein (9.3% to 0.0%, P<0.001). Net improvement of SI on right side remained significant after adjustment for left side (adjusted SI, 1.1 to 9.0; P=0.038). C-AVS was an independent predictor of adequate bilateral sampling in the multivariate model (odds ratio, 9.01; P<0.001). C-AVS improved the overall success rate of AVS, possibly as a result of better catheterization of right adrenal vein. Copyright © 2018 Korean Endocrine Society.
Batashev, Denis R.; Pakhomova, Marina V.; Razumovskaya, Anna V.; Voitsekhovskaja, Olga V.; Gamalei, Yuri V.
2013-01-01
The discovery of abundant plasmodesmata at the bundle sheath/phloem interface in Oleaceae (Gamalei, 1974) and Cucurbitaceae (Turgeon et al., 1975) raised the questions as to whether these plasmodesmata are functional in phloem loading and how widespread symplasmic loading would be. Analysis of over 800 dicot species allowed the definition of “open” and “closed” types of the minor vein phloem depending on the abundance of plasmodesmata between companion cells and bundle sheath (Gamalei, 1989, 1990). These types corresponded to potential symplasmic and apoplasmic phloem loaders, respectively; however, this definition covered a spectrum of diverse structures of phloem endings. Here, a review of detailed cytological analyses of minor veins in 320 species from the subclass Asteridae is presented, including data on companion cell types and their combinations which have not been reported previously. The percentage of Asteridae species with “open” minor vein cytology which also contain sieve-element-companion cell complexes with “closed” cytology, i.e., that show specialization for both symplasmic and apoplasmic phloem loading, was determined. Along with recent data confirming the dissimilar functional specialization of structurally different parts of minor vein phloem in the stachyose-translocating species Alonsoa meridionalis (Voitsekhovskaja et al., 2009), these findings suggest that apoplasmic loading is indispensable in a large group of species previously classified as putative symplasmic loaders. Altogether, this study provides formal classifications of companion cells and of minor veins, respectively, in 24 families of the Asteridae based on their structural features, opening the way to a close investigation of the relationship between structure and function in phloem loading. PMID:23970890
NASA Astrophysics Data System (ADS)
Sanfilippo, A.; Tribuzio, R.; Antonicelli, M.; Zanetti, A.
2017-12-01
We present a petrological/geochemical investigation of brown amphibole and felsic veins drilled during IODP 360 expedition at Atlantis Bank, a gabbroic oceanic core complex from Southwest Indian Ridge. The main purpose of this study is to unravel the role of seawater and magmatic components in the origin of these veins. Brown amphibole veins were collected at 90-170 mbsf. These veins typically include minor modal amounts of plagioclase and are associated with alteration halos made up of brown amphibole and whitish milky plagioclase in host gabbros. Two sets of late magmatic felsic veins, which mostly consist of plagioclase and minor brown amphibole, were selected. Amphibole-plagioclase geothermometry (Holland and Blundy, 1994) documents that crystallization of brown amphibole and felsic veins occurred in the 850-700 °C interval. In the brown amphibole veins, amphibole and plagioclase have relatively low concentrations of incompatible trace elements and significant Cl (0.2-0.3 wt%). The development of these veins at near surface levels is therefore attributed to seawater-derived fluids migrating downward through cracks developing in the exhuming gabbro. To explain the high temperature estimates for the development of these shallow veins, however, the seawater-derived fluids must have interacted not only with the gabbros, but also with a high temperature magmatic component. This petrogenetic hypothesis is consistent with oxygen and hydrogen isotopic compositions of amphiboles from shallow veins in adjacent Hole 735B gabbros (Alt and Bach, 2006). Trace element compositions of amphibole and plagioclase from the felsic veins show formation by silicate melts rich in incompatible elements. In addition, Cl concentrations in amphibole from the felsic veins are low, thereby indicating that the melts feeding these veins had low or no seawater component. We cautiously propose that: (i) the felsic veins were generated by SiO2-rich melts residual after crystallization of Fe-Ti-oxide phases, and (ii) the brown amphibole veins were generated by interaction of seawater-derived fluids with the late-stage residual melts rising through the gabbroic sequence.
Zhang, Jin-Shan; Li, Long; Cheng, Wei
2018-05-22
Patency of the bypass vein after a Rex shunt is an important indicator of prognosis. However, there is no report about the change of caliber of the bypass vein after a Rex shunt. The aim of this study was to identify postoperative changes of the bypass vein and to assess the relationship with prognosis. Between October 2008 and October 2016 in our center, 114 children were diagnosed with extrahepatic portal venous obstruction. The portal cavernoma-portal bypass with interposition of grafted portal vessels was performed in 31 children, the gastroportal shunt was performed in 54 children, and other Rex shunts were performed in another 29 children. At follow-up, the patency and diameter of the bypass vein were assessed with ultrasound and computed tomography. The intraoperative and postoperative diameters of the bypass vein were compared to identify postoperative changes of the bypass vein. Prognosis was compared between children with and children without an enlarged bypass vein. The caliber of the bypass vein was enlarged in 50% of children (40/80) at 6 months postoperatively. The postoperative incidences of rebleeding and esophageal varices were significantly lower in children with an enlarged bypass vein than in those without (P < .05). Postoperatively, the reduced splenic size was significantly higher in children with an enlarged bypass vein than in those without (P < .05). The postoperative increase in platelet count in children with an enlarged bypass vein was significantly higher than in those without (P = .006). There was no significant difference in the flow velocity of the bypass vein between children with and children without an enlarged bypass vein (P = .133). The portal pressure was significantly reduced after surgery in children with an enlarged bypass vein than in children without an enlarged bypass vein (P = .017). The caliber of the bypass vein increases in 50% of children after a Rex shunt using a grafted portal vessel, which is related to a better prognosis. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gonsalves, Carin F., E-mail: Carin.Gonsalves@mail.tju.edu; Eschelman, David J.; Sullivan, Kevin L.
2003-04-15
The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine cathetermore » dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had normal central veins. Three patients had central vein stenosis, and one had central vein occlusion. Subsequent venograms (n = 154)at the time of additional venous access device placement demonstrated 8 patients with occlusions and 10 with stenoses. Three of the 18 patients with abnormal follow-up venograms were found to have potential alternative causes of central vein abnormalities. Excluding these 3 patients and the 4 patients with abnormal initial venograms, a 7% incidence of central vein stenosis or occlusion was found in patients with prior indwelling catheters and normal initial venograms. Catheter caliber showed no effect on the subsequent development of central vein abnormalities. Patients who developed new or worsened central vein stenosis or occlusion had significantly (p =0.03) longer catheter dwell times than patients without central vein abnormalities. New central vein stenosis or occlusion occurred in 7% of patients following upper arm placement of venous access devices.Patients with longer catheter dwell time were more likely to develop central vein abnormalities. In order to preserve vascular access for dialysis fistulae and grafts and adhere to Dialysis Outcomes Quality Initiative guidelines, alternative venous access sites should be considered for patients with chronic renal insufficiency and end-stage renal disease.« less
Veins in the northern part of the Boulder batholith, Montana
Pinckney, D.M.
1965-01-01
About 20 miles north of Butte and extending nearly to Helena, is an area of 350 square miles containing hundreds of veins and altered zones. The bedrock of the area is 1) late Cretaceous volcanic rocks, forerunners of the Boulder batholith, 2) the Boulder batholith of late Cretaceous to early Tertiary age and 3) two groups of Tertiary volcanic rocks lying on the eroded batholith. The veins are post-batholith and pre-Tertiary in age. The veins are largely either quartz-sulfide veins of mesothermal type or chalcedony veins of epithermal type. The relations of these two types of veins have been the subject of conflicting ideas for 60 years. Three workers have proposed three different genetic classifications. This report shows that the quartz veins and the chalcedony veins are closely related parts of a strongly zoned hypogene vein system. Strong zonal patterns were established using the grain size of quartz (or pyrite vs. carbonate in one district) as well as features of the altered rocks. The scale of the zoning ranges from single veins through groups of veins or mining districts to the entire mineralized area. Single veins are zoned around a core of coarse-grained quartz; the quartz outward from the core becoming progressively finer-grained. The cores are zoned around eight major centers and several lesser ones. The centers and their nearby related veins are assigned to central, intermediate, and peripheral zones. Nearly all of the veins around the edge of the mineralized area are chalcedony. Envelopes of altered rocks consist of seven major bands representing three major groups of constituents, aluminum silicates, iron-bearing minerals, and silica. Plagioclase altered successively to montomorillite, kaolinite, and sericite; potassium feldspar altered to sericite (aluminum silicate group). Biotite released iron which formed successively, iron oxides, iron-bearing carbonate, and pyrite (iron-bearing minerals). Excess silica formed silicified bands. Constituents for which no stable phase occurs were largely leached from the rocks. A model has been constructed showing the arrangement of zoned veins and altered rocks in which the minerals produced by alteration are arranged in bands on each side of the vein, similar to the Butte pattern. Along strike from the cores, the inner bands thin and pinch out against the vein so that the vein becomes enclosed successively in the next outer bands. The sequence of alteration minerals along the veins is sericite, kaolinite, and montmorillonite for the aluminum silicates; and pyrite, carbonate, and iron oxides for the iron-bearing minerals. Alteration is thought to be controlled by reactions between wallrock minerals and the pore solution. In the aluminum silicate reactions, H+ was added to the rock and Na+ and Ca++ were removed. Carbon and sulfur from the vein were added to iron of the wallrock to produce pyrite and iron carbonate. Carbon, sulfur, and hydrogen moved into the wallrock, while Ca++, Na+, and some SiO2 moved toward the vein along concentration or activity gradients. Temperatures during mineralization ranged from below 200? C to about 350? C.
Evolution of kin recognition mechanisms in a fish.
Hain, Timothy J A; Garner, Shawn R; Ramnarine, Indar W; Neff, Bryan D
2017-03-01
Both selection and phylogenetic history can influence the evolution of phenotypic traits. Here we used recently characterized variation in kin recognition mechanisms among six guppy populations to explore the phylogenetic history of this trait. Guppies can use two different kin recognition mechanisms: either phenotype matching, in which individuals are identified based on comparison with a recognition template, or familiarity, in which individuals are remembered based on previous interactions. Across the six populations, we identified four transitions in recognition mechanism: phenotype matching evolved once and was subsequently lost in a single population, whereas familiarity evolved twice. Based on a molecular clock, these transitions occurred among populations that had diverged on a timescale of hundreds of thousands of years, which is two orders of magnitude faster than previously documented transitions in recognition mechanisms. A randomization test provided no evidence that recognition mechanisms were constrained by phylogeny, suggesting that recognition mechanisms have the capacity to evolve rapidly, although the specific selection pressures that may be contributing to variation in recognition mechanisms across populations remain unknown.
Experimental study on GMM-based speaker recognition
NASA Astrophysics Data System (ADS)
Ye, Wenxing; Wu, Dapeng; Nucci, Antonio
2010-04-01
Speaker recognition plays a very important role in the field of biometric security. In order to improve the recognition performance, many pattern recognition techniques have be explored in the literature. Among these techniques, the Gaussian Mixture Model (GMM) is proved to be an effective statistic model for speaker recognition and is used in most state-of-the-art speaker recognition systems. The GMM is used to represent the 'voice print' of a speaker through modeling the spectral characteristic of speech signals of the speaker. In this paper, we implement a speaker recognition system, which consists of preprocessing, Mel-Frequency Cepstrum Coefficients (MFCCs) based feature extraction, and GMM based classification. We test our system with TIDIGITS data set (325 speakers) and our own recordings of more than 200 speakers; our system achieves 100% correct recognition rate. Moreover, we also test our system under the scenario that training samples are from one language but test samples are from a different language; our system also achieves 100% correct recognition rate, which indicates that our system is language independent.
Appel, Esther; Heepe, Lars; Lin, Chung-Ping; Gorb, Stanislav N
2015-01-01
Dragonflies count among the most skilful of the flying insects. Their exceptional aerodynamic performance has been the subject of various studies. Morphological and kinematic investigations have showed that dragonfly wings, though being rather stiff, are able to undergo passive deformation during flight, thereby improving the aerodynamic performance. Resilin, a rubber-like protein, has been suggested to be a key component in insect wing flexibility and deformation in response to aerodynamic loads, and has been reported in various arthropod locomotor systems. It has already been found in wing vein joints, connecting longitudinal veins to cross veins, and was shown to endow the dragonfly wing with chordwise flexibility, thereby most likely influencing the dragonfly’s flight performance. The present study revealed that resilin is not only present in wing vein joints, but also in the internal cuticle layers of veins in wings of Sympetrum vulgatum (SV) and Matrona basilaris basilaris (MBB). Combined with other structural features of wing veins, such as number and thickness of cuticle layers, material composition, and cross-sectional shape, resilin most probably has an effect on the vein′s material properties and the degree of elastic deformations. In order to elucidate the wing vein ultrastructure and the exact localisation of resilin in the internal layers of the vein cuticle, the approaches of bright-field light microscopy, wide-field fluorescence microscopy, confocal laser-scanning microscopy, scanning electron microscopy and transmission electron microscopy were combined. Wing veins were shown to consist of up to six different cuticle layers and a single row of underlying epidermal cells. In wing veins of MBB, the latter are densely packed with light-scattering spheres, previously shown to produce structural colours in the form of quasiordered arrays. Longitudinal and cross veins differ significantly in relative thickness of exo- and endocuticle, with cross veins showing a much thicker exocuticle. The presence of resilin in the unsclerotised endocuticle suggests its contribution to an increased energy storage and material flexibility, thus to the prevention of vein damage. This is especially important in the highly stressed longitudinal veins, which have much lower possibility to yield to applied loads with the aid of vein joints, as the cross veins do. These results may be relevant not only for biologists, but may also contribute to optimise the design of micro-air vehicles. PMID:26352411
Gender recognition from unconstrained and articulated human body.
Wu, Qin; Guo, Guodong
2014-01-01
Gender recognition has many useful applications, ranging from business intelligence to image search and social activity analysis. Traditional research on gender recognition focuses on face images in a constrained environment. This paper proposes a method for gender recognition in articulated human body images acquired from an unconstrained environment in the real world. A systematic study of some critical issues in body-based gender recognition, such as which body parts are informative, how many body parts are needed to combine together, and what representations are good for articulated body-based gender recognition, is also presented. This paper also pursues data fusion schemes and efficient feature dimensionality reduction based on the partial least squares estimation. Extensive experiments are performed on two unconstrained databases which have not been explored before for gender recognition.
Gender Recognition from Unconstrained and Articulated Human Body
Wu, Qin; Guo, Guodong
2014-01-01
Gender recognition has many useful applications, ranging from business intelligence to image search and social activity analysis. Traditional research on gender recognition focuses on face images in a constrained environment. This paper proposes a method for gender recognition in articulated human body images acquired from an unconstrained environment in the real world. A systematic study of some critical issues in body-based gender recognition, such as which body parts are informative, how many body parts are needed to combine together, and what representations are good for articulated body-based gender recognition, is also presented. This paper also pursues data fusion schemes and efficient feature dimensionality reduction based on the partial least squares estimation. Extensive experiments are performed on two unconstrained databases which have not been explored before for gender recognition. PMID:24977203
Ravik, Monika; Havnes, Anton; Bjørk, Ida Torunn
2017-12-01
To explore, describe and compare learning actions that nursing students used during peripheral vein cannulation training on a latex arm or each other's arms in a clinical skills centre. Simulation-based training is thought to enhance learning and transfer of learning from simulation to the clinical setting and is commonly recommended in nursing education. What students actually are doing during simulation-based training is, however, less explored. The analysis of learning actions used during simulation-based training could contribute to development and improvement of simulation as a learning strategy in nursing education. A qualitative explorative and descriptive research design, involving content analysis of video recordings, was used. Video-supported observation of nine nursing students practicing vein cannulation was conducted in a clinical skills centre in late 2012. The students engaged in various learning actions. Students training on a latex arm used a considerably higher number of learning actions relative to those training on each other's arms. In both groups, students' learning actions consisted mainly of seeking and giving support. The teacher provided students training on each other's arms with detailed feedback regarding insertion of the cannula into the vein, while those training on a latex arm received sparse feedback from the teacher and fellow students. The teacher played an important role in facilitating nursing students' practical skill learning during simulation. The provision of support from both teachers and students should be emphasised to ensure that nursing students' learning needs are met. This study suggest that student nurses may be differently and inadequately prepared in peripheral vein cannulation in two simulation modalities used in the academic setting; training on a latex arm and on each other's arms. © 2017 John Wiley & Sons Ltd.
Marginal hepatectomy in the rat: from anatomy to surgery.
Madrahimov, Nodir; Dirsch, Olaf; Broelsch, Christoph; Dahmen, Uta
2006-07-01
Based on the 3-dimensional visualization of vascular supply and drainage, a vessel-oriented resection technique was optimized. The new surgical technique was used to determine the maximal reduction in liver mass enabling a 50% 1-week survival rate. Determination of the minimal liver mass is necessary in clinical as well as in experimental liver surgery. In rats, survival seems to depend on the surgical technique applied. Extended hepatectomy with removal of 90% of the liver mass was long regarded as a lethal model. Introduction of a vessel-oriented approach enabled long-term survival in this model. The lobar and vascular anatomy of rat livers was visualized by plastination of the whole organ, respectively, by corrosion casts of the portal vein, hepatic artery and liver veins. The three-dimensional models were used to extract the underlying anatomic structure. In 90% partial hepatectomy, the liver parenchyma was clamped close to the base of the respective liver lobes (left lateral, median and right, liver lobe). Piercing sutures were placed through the liver parenchyma, so that the stem of portal vein and the accompanying hepatic artery but also the hepatic vein were included. A 1-week survival rate of 100% was achieved after 90% hepatectomy. Extending the procedure to 95% resection by additional removal of the upper caudate lobe led to a 1-week survival rate of 66%; 97% partial hepatectomy, accomplished by additional resection of the lower caudate lobe only leaving the paracaval parts of the liver behind, resulted in 100% lethality within 4 days. Using a anatomically based, vessel-oriented, parenchyma-preserving surgical technique in 95% liver resections led to long-term survival. This represents the maximal reduction of liver mass compatible with survival.
Frappé, P; Buchmuller-Cordier, A; Bertoletti, L; Bonithon-Kopp, C; Couzan, S; Lafond, P; Leizorovicz, A; Merah, A; Presles, E; Preynat, P; Tardy, B; Décousus, H
2014-06-01
The incidence of superficial vein thrombosis (SVT) in the general adult population remains unknown. To assess the annual diagnosis rate of symptomatic, objectively confirmed lower limb SVT, associated or not with concomitant deep vein thrombosis and/or symptomatic pulmonary embolism. We conducted, from November 14, 2011, to November 13, 2012, a multicenter, community-based study in the Saint-Etienne urban area, France, representing a population of 265 687 adult residents (according to the 2009 census). All 248 general practitioners located within the area were asked to refer any patient with clinically suspected lower limb acute SVT to a vascular physician for systematic compression ultrasonography. All 28 vascular physicians located within the area participated in the study. The annual diagnosis rate, with the corresponding 95% confidence interval (CI), was calculated as the number of patients with symptomatic, objectively confirmed SVT divided by the number of person-years at risk defined by population data of the area. All venous thromboembolic events were validated by an independent central adjudication committee. Overall, 171 patients with symptomatic, confirmed SVT were reported. The annual diagnosis rate was 0.64& (95% CI, 0.55%-0.74&), was higher in women, and increased with advancing age regardless of gender [corrected]. Concomitant deep vein thrombosis (20 proximal) was observed in 42 patients (24.6% [95% CI, 18.3%-31.7%]), and concomitant symptomatic pulmonary embolism was observed in eight patients (4.7% [95% CI, 2.0%-9.0%]). This first community-based study showed that symptomatic SVT with confirmed diagnosis is a relatively common disease frequently associated with thromboembolic events in the deep venous system. © 2014 International Society on Thrombosis and Haemostasis.
Assessment and management of patients with varicose veins.
Allen, Louise
Varicose veins are enlarged superficial veins found in the legs. This article explores the anatomy and physiology of the venous system to assist nurses to assess, manage and treat patients with varicose veins.
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Souza, Estelle S.; Williams, David M.; Deeb, G.M.
2006-10-15
Ehlers-Danlos syndrome (EDS) type IV is a rare connective tissue disorder associated with thin-walled, friable arteries and veins predisposing patients to aneurysm formation, dissection, fistula formation, and vessel rupture. Azygos vein aneurysm is an extremely rare condition which has not been reported in association with EDS in the literature. We present a patient with EDS type IV and interrupted inferior vena cava (IVC) with azygos continuation who developed an azygos vein aneurysm. In order to decrease flow through the azygos vein and reduce the risk of aneurysm rupture, a stent-graft shunt was created from the right hepatic vein to themore » azygos vein via a transhepatic, retroperitoneal route. At 6 month follow-up the shunt was open and the azygos vein aneurysm had resolved.« less
Toward standardized mapping for left atrial analysis and cardiac ablation guidance
NASA Astrophysics Data System (ADS)
Rettmann, M. E.; Holmes, D. R.; Linte, C. A.; Packer, D. L.; Robb, R. A.
2014-03-01
In catheter-based cardiac ablation, the pulmonary vein ostia are important landmarks for guiding the ablation procedure, and for this reason, have been the focus of many studies quantifying their size, structure, and variability. Analysis of pulmonary vein structure, however, has been limited by the lack of a standardized reference space for population based studies. Standardized maps are important tools for characterizing anatomic variability across subjects with the goal of separating normal inter-subject variability from abnormal variability associated with disease. In this work, we describe a novel technique for computing flat maps of left atrial anatomy in a standardized space. A flat map of left atrial anatomy is created by casting a single ray through the volume and systematically rotating the camera viewpoint to obtain the entire field of view. The technique is validated by assessing preservation of relative surface areas and distances between the original 3D geometry and the flat map geometry. The proposed methodology is demonstrated on 10 subjects which are subsequently combined to form a probabilistic map of anatomic location for each of the pulmonary vein ostia and the boundary of the left atrial appendage. The probabilistic map demonstrates that the location of the inferior ostia have higher variability than the superior ostia and the variability of the left atrial appendage is similar to the superior pulmonary veins. This technique could also have potential application in mapping electrophysiology data, radio-frequency ablation burns, or treatment planning in cardiac ablation therapy.
Fang, Chi-hua; Kong, Deshuai; Wang, Xiaojun; Wang, Huaizhi; Xiang, Nan; Fan, Yingfang; Yang, Jian; Zhong, Shi Zheng
2014-04-01
This study aimed to investigate the clinical significance of 3-dimensional (3D) reconstruction of peripancreatic vessels for patients with suspected pancreatic cancer (PC). A total of 89 patients with PC were included; 60 patients randomly underwent computed tomographic angiography. Based on the findings of 3D reconstruction of peripancreatic vessels, the appropriate method for individualized tumor resection was determined. These patients were compared with 29 conventionally treated patients with PC. The rate of visualization was 100% for great vessels around the pancreas. The detection rates for anterior superior pancreaticoduodenal artery, posterior superior pancreaticoduodenal artery, anterior inferior pancreaticoduodenal artery, posterior inferior pancreaticoduodenal artery, dorsal pancreatic artery, superior marginal arterial branch of the pancreatic head, anterior superior pancreaticoduodenal vein, posterior superior pancreaticoduodenal vein, anterior inferior pancreaticoduodenal vein, and posterior inferior pancreaticoduodenal vein were 86.6%, 85.0%, 76.6%, 71.6%, 91.6%, 53.3%, 61.6%, 55.0%, 43.3%, and 51.6%, respectively. Forty-three patients who had undergone 3D reconstruction underwent surgery. Of the 29 conventionally treated patients, 19 underwent surgery. The operative time, blood loss, length of hospital stay, and complication incidence of the 43 patients were superior to that of the 19 patients. A peripancreatic vascular reconstruction can reveal the vascular anatomy, variations of peripancreatic vascular, and tumor-induced vascular changes; the application of the simulation surgery platform could reduce surgical trauma and decrease operative time.
Augmented reality-guided artery-first pancreatico-duodenectomy.
Marzano, Ettore; Piardi, Tullio; Soler, Luc; Diana, Michele; Mutter, Didier; Marescaux, Jacques; Pessaux, Patrick
2013-11-01
Augmented Reality (AR) in surgery consists in the fusion of synthetic computer-generated images (3D virtual model) obtained from medical imaging preoperative work-up and real-time patient images with the aim to visualize unapparent anatomical details. The potential of AR navigation as a tool to improve safety of the surgical dissection is presented in a case of pancreatico-duodenectomy (PD). A 77-year-old male patient underwent an AR-assisted PD. The 3D virtual anatomical model was obtained from thoraco-abdominal CT scan using customary software (VR-RENDER®, IRCAD). The virtual model was superimposed to the operative field using an Exoscope (VITOM®, Karl Storz, Tüttlingen, Germany) as well as different visible landmarks (inferior vena cava, left renal vein, aorta, superior mesenteric vein, inferior margin of the pancreas). A computer scientist manually registered virtual and real images using a video mixer (MX 70; Panasonic, Secaucus, NJ) in real time. Dissection of the superior mesenteric artery and the hanging maneuver were performed under AR guidance along the hanging plane. AR allowed for precise and safe recognition of all the important vascular structures. Operative time was 360 min. AR display and fine registration was performed within 6 min. The postoperative course was uneventful. The pathology was positive for ampullary adenocarcinoma; the final stage was pT1N0 (0/43 retrieved lymph nodes) with clear surgical margins. AR is a valuable navigation tool that can enhance the ability to achieve a safe surgical resection during PD.
Can Changes in Eye Movement Scanning Alter the Age-Related Deficit in Recognition Memory?
Chan, Jessica P. K.; Kamino, Daphne; Binns, Malcolm A.; Ryan, Jennifer D.
2011-01-01
Older adults typically exhibit poorer face recognition compared to younger adults. These recognition differences may be due to underlying age-related changes in eye movement scanning. We examined whether older adults’ recognition could be improved by yoking their eye movements to those of younger adults. Participants studied younger and older faces, under free viewing conditions (bases), through a gaze-contingent moving window (own), or a moving window which replayed the eye movements of a base participant (yoked). During the recognition test, participants freely viewed the faces with no viewing restrictions. Own-age recognition biases were observed for older adults in all viewing conditions, suggesting that this effect occurs independently of scanning. Participants in the bases condition had the highest recognition accuracy, and participants in the yoked condition were more accurate than participants in the own condition. Among yoked participants, recognition did not depend on age of the base participant. These results suggest that successful encoding for all participants requires the bottom-up contribution of peripheral information, regardless of the locus of control of the viewer. Although altering the pattern of eye movements did not increase recognition, the amount of sampling of the face during encoding predicted subsequent recognition accuracy for all participants. Increased sampling may confer some advantages for subsequent recognition, particularly for people who have declining memory abilities. PMID:21687460
Caine, Jonathan S.; Nelson, E.P.; Beach, S.T.; Layer, P.W.
2006-01-01
The Idaho Springs and Central City mining districts form the central portion of a structurally controlled hydrothermal precious- and base-metal vein system in the Front Range of the northeast-trending Colorado Mineral Belt. Three new 40Ar/39Ar plateau ages on hydrothermal sericite indicate the veins formed during the Laramide orogeny between 65.4??1.5 - 61.9??1.3 Ma. We compile structural geologic data from surface geological maps, subsurface mine maps, and theses for analysis using modern graphical methods and integration into models of formation of economic mineral deposits. Structural data sets, produced in the 1950s and 1960s by the U.S. Geological Survey, are compiled for fabric elements, including metamorphic foliations, fold axial trends, major brittle fault zones, quartz and precious- and base-metal veins and fault veins, Tertiary dikes, and joints. These fabric elements are plotted on equal-area projections and analyzed for mean fabric orientations. Strike-slip fault-vein sets are mostly parallel or sub-parallel, and not conjugate as interpreted by previous work; late-stage, normal-slip fault veins possibly show a pattern indicative of triaxial strain. Fault-slip kinematic analysis was used to model the trend of the Laramide maximum horizontal stress axis, or compression direction, and to determine compatibility of opening and shear motions within a single stress field. The combined-model maximum compression direction for all strike slip fault veins is ???068??, which is consistent with published Laramide compression directions of ???064?? (mean of 23 regional models) and ???072?? for the Front Range uplift. The orientations of fabric elements were analyzed for mechanical and kinematic compatibility with opening, and thus permeability enhancement, in the modeled regional east-northeast, Laramide compression direction. The fabric orientation analysis and paleostress modeling show that structural permeability during mineralization was enhanced along pre-existing metamorphic foliations and fold axial planes. Large orientation dispersion in most fabric elements likely caused myriad potential pathways for permeability. The dominant orientations of opening and shear mode structures are consistent with a sub-parallel network of structures that formed in the Laramide east-northeast compression direction. The results presented demonstrate the importance of using mechanical and kinematic theory integrated with contemporary ideas of permeability structure to better understand the coupled nature of fluid flow, mineral deposition, stress, and strain. Further, the results demonstrate that there is significant internal strain within this basement-cored uplift that was localized by optimally oriented pre-existing structures in a regional stress field.
Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus
2016-04-01
In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.
Histomorphological Assessment of Phlebitis in Renal Allografts
Jurčić, Vesna; Jeruc, Jera; Marić, Stela; Ferluga, Dušan
2007-01-01
Aim To evaluate the histomorphological features of veins in normal and transplanted kidneys. Methods Between 1992 and 1997 at the Institute of Pathology in Ljubljana, we semiquantitatively evaluated histomorphological changes in veins in nephrectomy specimens of 29 renal allografts with rejection and in 31 control kidneys. The structure of different segments of renal veins was additionally analyzed. Results Small interlobular veins were composed of endothelium and basement membrane, similar to capillaries, while the walls of large interlobular and arcuate veins had smooth muscle cell bundles forming the medial layer, similar to large extrarenal veins. In the control group, only focal mononuclear infiltration around small interlobular veins was found (8/31). In rejected kidney allografts, the veins were frequently infiltrated with inflammatory cells, predominantly T lymphocytes and macrophages (29/29). Other changes included thrombosis (16/29), fibrinoid necrosis (7/29), and sclerosis (9/29), and in one case an intimal lipid deposition. Conclusion This study, performed on whole explanted kidney specimens, revealed that rejection vasculitis often involved extrarenal and intrarenal veins, showing a whole spectrum of histopathological changes similar to those in arteries. Since large intrarenal veins have a muscle wall, we believe that the term »rejection phlebitis« could be used in renal transplant pathology. PMID:17589975
Shida, Takuya; Umezu, Mitsuo; Iwasaki, Kiyotaka
2018-06-01
We analyzed the adverse events associated with an off-label use of arterial stents and CE-marked iliac vein stents for the treatment of iliac venous thromboembolism and investigated their relationships with the anatomical features of the iliac vein, to gain insights into the development of a better iliac vein stent. Reports of adverse events following the use of stents in the iliac vein were retrieved from the Manufacturer and User Facility Device Experience (MAUDE) database that contain suspected device-associated complications reported to the Food and Drug Administration. Data from 2006 to 2016 were investigated. The literature analysis was also conducted using PubMed, Cochrane Library, EMBASE, and Web of Science focusing on English articles published up to 4 October 2016. The analysis of 88 adverse events from the MAUDE database and 182 articles from the literature revealed that a higher number of adverse events had been reported following the use of arterial stents in the iliac vein compared to CE-marked iliac vein stents. While stent migration and shortening were reported only for the arterial stents, stent fracture and compression occurred regardless of the stent type, even though a vein does not pulsate. A study of the anatomical features of the iliac vein implies that bending, compression, and kink loads are applied to the iliac vein stents in vivo. For designing, developing, and pre-clinical testing of stents intended for use in the iliac vein, the above mechanical load environments induced by the anatomical features should be considered.
Mousa, Albeir Y; Broce, Mike; Yacoub, Michael; AbuRahma, Ali F
2016-07-01
Treatment of venous ulcers is demanding for patients, as well as clinicians, and the investigation of underlying venous hypertension is the cornerstone of therapy. We propose that occult iliac vein stenosis should be ruled out by iliac vein interrogation (IVI) in patients with advanced venous stasis. We conducted a systematic retrospective analysis of a consecutive series of patients who presented with CEAP (clinical, etiological, anatomical, and pathophysiological) 6 venous disease. All patients had great saphenous vein ablation, compressive treatment, wound care (including Unna boot compression), and perforator closure using ablation therapy. Iliac vein stenosis was defined as ≥50% stenosis in cross-sectional surface area on intravascular ultrasound. Primary outcomes include time of venous ulcer healing and/or measurable change in the Venous Clinical Severity Score. Twenty-two patients with CEAP 6 venous disease met the inclusion criteria (active ulcers >1.5 cm in diameter). The average age and body mass index were 62.2 ± 9.2 years and 41.7 ± 16.7, respectively. The majority were female (72.7%) with common comorbidities, such as hyperlipidemia (54.5%), hypertension (36.4%), and diabetes mellitus (27.3%). Twenty-nine ulcers with an average diameter of 3.4 ± 1.9 cm and a depth of 2.2 ± 0.5 mm were treated. The majority of the ulcers occurred on the left limb (n = 17, 58.6%). Average perforator venous reflux was 3.6 ± 0.8 sec, while common femoral reflux was 1.8 ± 1.6. The majority (n = 19, 64.5%) of the perforator veins were located at the base of the ulcer, while the remainder (n = 10, 34.5%) were within 2 cm from the base. Of the 13 patients who underwent IVI, 8 patients (61.5%) had stenosis >50% that was corrected with iliac vein angioplasty and stenting (IVAS). There was a strong trend toward shorter healing time in the IVI group (7.9 ± 9.5 weeks) than for patients in the no iliac vein interrogation (NIVI) group (20.2 ± 15.3 weeks, P = 0.055). The final VCCS score was not significantly different (IVI = 7.9 ± 9.5 vs. NIVI = 10.0 ± 6.5, P = 0.578). However, compared with the NIVI group, the healing time for patients who actually received IVAS was marginally lower (5.8 ± 3.6 weeks, P = 0.075) and final VCCS was significantly lower (2.4 ± 2.9, P = 0.031). Veins that received IVI and IVAS remained patent and the associated ulcers were healed (100%). The small sample size and retrospective design limit the strength of the conclusions but the findings suggest that further studies are needed to define the exact role of IVI including angioplasty/stenting for patients with chronic venous ulcers. Copyright © 2016 Elsevier Inc. All rights reserved.
2017-12-28
Cerebral Vein Thrombosis; Deep Vein Thrombosis; Gonadal Thrombosis; Hepatic Thrombosis; Malignant Neoplasm; Mesenteric Thrombosis; Metastatic Malignant Neoplasm; Portal Vein Thrombosis; Pulmonary Embolism; Renal Vein Thrombosis; Splenic Thrombosis; Venous Thromboembolism
Dua, Anahita; Heller, Jennifer; Lee, Cheong
2017-11-01
Phlegmasia cerulea dolens (PCD) is a rare condition resulting from venous occlusion that impairs arterial flow. We report a rare case of post-traumatic PCD after ligation of the iliac vein with successful treatment by right-to-left femoral vein to femoral vein bypass using left great saphenous vein (Palma procedure). The clinical presentation, diagnostic process, and approach to management along with a literature review on the operative management of PCD are presented in this case report.
Kibrik, Pavel; Eisenberg, Justin; Alsheekh, Ahmad; Rizvi, Syed Ali; Aurshina, Afsha; Marks, Natalie; Hingorani, Anil; Ascher, Enrico
2018-02-01
Objectives Treatment options for venous insufficiency are rapidly evolving in the office setting and include venography, intravascular ultrasound, and venous stenting. Non-thrombotic iliac vein lesions assessment and treatment in an office setting is currently an area of interest. The purpose of this study is to demonstrate the safety and efficacy of evaluating non-thrombotic iliac vein lesion with this office-based procedure in octogenarians and nonagenarians. Methods From January 2012 through December 2013, 300 non-thrombotic iliac vein lesion limbs in 192 patients with venous insufficiency ≥80 years old were evaluated for non-thrombotic iliac vein lesion. Patients were evaluated and treated with venography, intravascular ultrasound, and stent placement for significant lesions demonstrated by greater than 50% diameter or cross-sectional area reduction. Group 1: 168 of these patients were octogenarians; female/male ratio was 1.75:1, bilateral in 89/168 patients (53%), left sided in 131/259 limbs (51%), right sided in 128 limbs (49%), average age 83.5 ± 2.6 years (range 80-89) compared to Group 2: 24 nonagenarians; female/male was 3:1, bilateral in 17/24 patients (70%), left sided in 20/41 limbs (49%), right sided in 21/41 limbs (51%), average age 92.9 ± 2.2 years (range 90-99). Stent related outcomes were evaluated with communication to the patient within 24 h to assess post-procedure pain followed by serial iliocaval ultrasonography. Results Out of the 300 limbs evaluated, in Group 1, 86% of limbs had stents placed compared to 90% in Group 2 and 11% of both groups had two stents placed. Overall improvement in pain, edema, and ulcers was reported in 147 (59%) of octogenarians and 24 (65%) of nonagenarians. There were no surgical site infections, pseudo-aneurysms, arteriovenous fistulas, or femoral artery injuries. No patients required transfusion within three days post-operatively and there were no 30-day mortalities in both sets of patients. Conclusions Our results demonstrate that there is no statistical difference in the outcome of performing venography, intravascular ultrasound, and stent placement in an office-based setting in octogenarians and nonagenarians. Both groups maintained a similar safety profile with low morbidity and mortality. In conclusion, we believe that the treatment of non-thrombotic iliac vein lesion in an office-based setting is safe and efficacious in both groups.
Recognition Decisions from Visual Working Memory Are Mediated by Continuous Latent Strengths
ERIC Educational Resources Information Center
Ricker, Timothy J.; Thiele, Jonathan E.; Swagman, April R.; Rouder, Jeffrey N.
2017-01-01
Making recognition decisions often requires us to reference the contents of working memory, the information available for ongoing cognitive processing. As such, understanding how recognition decisions are made when based on the contents of working memory is of critical importance. In this work we examine whether recognition decisions based on the…
The Suitability of Cloud-Based Speech Recognition Engines for Language Learning
ERIC Educational Resources Information Center
Daniels, Paul; Iwago, Koji
2017-01-01
As online automatic speech recognition (ASR) engines become more accurate and more widely implemented with call software, it becomes important to evaluate the effectiveness and the accuracy of these recognition engines using authentic speech samples. This study investigates two of the most prominent cloud-based speech recognition engines--Apple's…
Joseph, Arun Antony; Merboldt, Klaus-Dietmar; Voit, Dirk; Dahm, Johannes; Frahm, Jens
2016-12-01
The accurate assessment of peripheral venous flow is important for the early diagnosis and treatment of disorders such as deep-vein thrombosis (DVT) which is a major cause of post-thrombotic syndrome or even death due to pulmonary embolism. The aim of this work is to quantitatively determine blood flow in deep veins during rest and muscular exercise using a novel real-time magnetic resonance imaging (MRI) method for velocity-encoded phase-contrast (PC) MRI at high spatiotemporal resolution. Real-time PC MRI of eight healthy volunteers and one patient was performed at 3 Tesla (Prisma fit, Siemens, Erlangen, Germany) using a flexible 16-channel receive coil (Variety, NORAS, Hoechberg, Germany). Acquisitions were based on a highly undersampled radial FLASH sequence with image reconstruction by regularized nonlinear inversion at 0.5×0.5×6 mm 3 spatial resolution and 100 ms temporal resolution. Flow was assessed in two cross-sections of the lower leg at the level of the calf muscle and knee using a protocol of 10 s rest, 20 s flexion and extension of the foot, and 10 s rest. Quantitative analyses included through-plane flow in the right posterior tibial, right peroneal and popliteal vein (PC maps) as well as signal intensity changes due to flow and muscle movements (corresponding magnitude images). Real-time PC MRI successfully monitored the dynamics of venous flow at high spatiotemporal resolution and clearly demonstrated increased flow in deep veins in response to flexion and extension of the foot. In normal subjects, the maximum velocity (averaged across vessel lumen) during exercise was 9.4±5.7 cm·s -1 for the right peroneal vein, 8.5±4.6 cm·s -1 for the right posterior tibial vein and 17.8±5.8 cm·s -1 for the popliteal vein. The integrated flow volume per exercise (20 s) was 1.9, 1.6 and 50 mL (mean across subjects) for right peroneal, right posterior tibial and popliteal vein, respectively. A patient with DVT presented with peak flow velocities of only about 2 cm·s -1 during exercise and less than 1 cm·s -1 during rest. Real-time PC MRI emerges as a new tool for quantifying the dynamics of muscle-induced flow in deep veins. The method provides both signal intensity changes and velocity information for the assessment of blood flow and muscle movements. It now warrants extended clinical trials to patients with suspected thrombosis.
Yavuz, Turhan; Acar, Altay Nihat; Aydın, Huseyin; Ekingen, Evren
2018-01-01
Objective This study aims to present the early results of a retrospective study of the use of novel n-butyl-2-cyanoacrylate (VenaBlock)-based nontumescent endovenous ablation with a guiding light for the treatment of patients with varicose veins. Methods Patients with lower limb venous insufficiency were treated with n-butyl-2-cyanoacrylate (VenaBlock Venous Closure System) between April 2016 and July 2016. The study enrolled adults aged 21-70 years with symptomatic moderate to severe varicosities (C2-C4b) and great saphenous vein reflux lasting longer than 0.5 s with great saphenous vein diameter between 5.5 and 15 mm assessed in the standing position. No compression stockings were used after the procedure. Duplex ultrasound imaging and clinical follow-up were performed on the third day, first month, sixth month, and 12th month. Clinical, etiological, anatomical, pathophysiological classification; venous clinical severity score; and completed Aberdeen varicose vein questionnaire were recorded. Results Five hundred thirty-eight patients with great saphenous vein incompetency underwent n-butyl-2-cyanoacrylate ablation. The mean ablation length was 25.69 ± 4.8 cm, and the average amount of n-butyl-2-cyanoacrylate delivered was 0.87 ± 0.15 ml. The mean procedure time was 11.7 ± 4.9 min. Procedural success was 100%, and complete occlusion was observed after treatment and at the third-day follow-up. We observed ecchymosis in five patients (1.00%) at the entry site at the third-day follow-up. Phlebitis was encountered with six (1.20%) patients. No skin pigmentation, hematoma, paresthesia, deep vein thrombosis, or pulmonary embolism was observed. Kaplan-Meier analysis yielded an occlusion rate of 99.4% at the 12-month follow-up. All patients had significant improvement in venous clinical severity score and Aberdeen varicose vein questionnaire scores postoperatively ( p <0.0001). Venous clinical severity score scores decreased from 5.43 ± 0.87 to 0.6 ± 0.75. Aberdeen varicose vein questionnaire scores decreased from 18.32 ± 5.24 to 4.61 ± 1.42. Conclusions The procedure appears to be feasible, safe, and efficient in treating the great majority of incompetent great saphenous veins with this technique.
Element variations in rhyolitic magma resulting from gas transport
NASA Astrophysics Data System (ADS)
Berlo, K.; Tuffen, H.; Smith, V. C.; Castro, J. M.; Pyle, D. M.; Mather, T. A.; Geraki, K.
2013-11-01
Tuffisite veins are glass-filled fractures formed when magma fragments during degassing within the conduit. These veins form transient channels through which exsolved gases can escape from magma. The purpose of this study is to determine the extent to which chemical heterogeneity within the melt results from gas transport, and assess how this can be used to study magma degassing. Two tuffisite veins from contrasting rhyolitic eruptions at Torfajökull (Iceland) and Chaitén (Chile) were studied in detail. The tuffisite vein from Torfajökull is from a shallow dissected conduit (∼70 ka) that fed a degassed lava flow, while the sample from Chaitén was a bomb ejected during the waning phases of Plinian activity in May 2008. The results of detailed in situ chemical analyses (synchrotron XRF, FTIR, LA-ICP-MS) show that in both veins larger vesiculated fragments are enriched in volatile elements (Torfajökull: H, Li, Cl; Chaitén: Li, Cl, Cu, Zn, As, Sn, Sb) compared to the host, while the surrounding smaller particles are depleted in the Torfajökull vein (Li, Cl, Zn, Br, Rb, Pb), but enriched in the Chaitén vein (K, Cu, Zn, As, Mo, Sb, Pb). The lifespans of both veins and the fluxes of gas and particles through them can be estimated using diffusion profiles and enrichment factors. The Torfajökull vein had a longer lifespan (∼a day) and low particle velocities (∼cm/s), while the Chaitén vein was shorter lived (<1 h) with a high gas velocity (∼m/s). These differences are consistent with the contrasting eruption mechanisms (effusive vs. explosive). The amount of magma that degassed through the Chaitén vein is more than ten times the volume of the vein itself, requiring the vein to tap into pre-exsolved gas pockets. This study highlights that tuffisite veins are highly efficient gas pathways and thereby impart chemical diversity in volatile elements on the melt.
Adhikari, Srikar; Zeger, Wes; Thom, Christopher; Fields, J Matthew
2015-09-01
Two-point compression ultrasonography focuses on the evaluation of common femoral and popliteal veins for complete compressibility. The presence of isolated thrombi in proximal veins other than the common femoral and popliteal veins should prompt modification of 2-point compression technique. The objective of this study is to determine the prevalence and distribution of deep venous thrombi isolated to lower-extremity veins other than the common femoral and popliteal veins in emergency department (ED) patients with clinically suspected deep venous thrombosis. This was a retrospective study of all adult ED patients who received a lower-extremity venous duplex ultrasonographic examination for evaluation of deep venous thrombosis during a 6-year period. The ultrasonographic protocol included B-mode, color-flow, and spectral Doppler scanning of the common femoral, femoral, deep femoral, popliteal, and calf veins. Deep venous thrombosis was detected in 362 of 2,451 patients (14.7%; 95% confidence interval [CI] 13.3% to 16.1%). Thrombus confined to the common femoral vein alone was found in 5 of 362 cases (1.4%; 95% CI 0.2% to 2.6%). Isolated femoral vein thrombus was identified in 20 of 362 patients (5.5%; 95% CI 3.2% to 7.9%). Isolated deep femoral vein thrombus was found in 3 of 362 cases (0.8%; 95% CI -0.1% to 1.8%). Thrombus in the popliteal vein alone was identified in 53 of 362 cases (14.6%; 95% CI 11% to 18.2%). In our study, 6.3% of ED patients with suspected deep venous thrombosis had isolated thrombi in proximal veins other than common femoral and popliteal veins. Our study results support the addition of femoral and deep femoral vein evaluation to standard compression ultrasonography of the common femoral and popliteal vein, assuming that this does not have a deleterious effect on specificity. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Schrauben, E M; Johnson, K M; Huston, J; Del Rio, A M; Reeder, S B; Field, A; Wieben, O
2014-05-01
The chronic cerebrospinal venous insufficiency hypothesis raises interest in cerebrospinal venous blood flow imaging, which is more complex and less established than in arteries. For accurate assessment of venous flow in chronic cerebrospinal venous insufficiency diagnosis and research, we must account for physiologic changes in flow patterns. This study examines day-to-day flow variability in cerebrospinal veins by use of 4D MR flow and contrast-enhanced MRA under typical, uncontrolled conditions in healthy individuals. Ten healthy volunteers were scanned in a test-retest fashion by use of a 4D flow MR imaging technique and contrast-enhanced MRA. Flow parameters obtained from phase contrast-vastly undersampled isotropic projection reconstruction and contrast-enhanced MRA scoring measurements in the head, neck, and chest veins were analyzed for internal consistency and interscan reproducibility. Internal consistency was satisfied at the torcular herophili, with an input-output difference of 2.2%. Percentages of variations in flow were 20.3%, internal jugular vein; 20.4%, azygos vein; 6.8%, transverse sinus; and 5.1%, common carotid artery. Retrograde flow was found in the lower internal jugular vein (4.8%) and azygos vein (7.2%). Contrast-enhanced MRA interscan κ values for the internal jugular vein (left: 0.474, right: 0.366) and azygos vein (-0.053) showed poor interscan agreement. Phase contrast-vastly undersampled isotropic projection reconstruction blood flow measurements are reliable and highly reproducible in intracranial veins and in the common carotid artery but not in veins of the neck (internal jugular vein) and chest (azygos vein) because of normal physiologic variation. Retrograde flow normally may be observed in the lower internal jugular vein and azygos vein. Low interrater agreement in contrast-enhanced MRA scans was observed. These findings have important implications for imaging diagnosis and experimental research of chronic cerebrospinal venous insufficiency. © 2014 by American Journal of Neuroradiology.
Iliac Vein Compression Syndrome due to Bladder Distention Caused by Urethral Calculi
Ikegami, Akiko; Kondo, Takeshi; Tsukamoto, Tomoko; Ohira, Yoshiyuki; Ikusaka, Masatomi
2015-01-01
We report a rare case of iliac vein compression syndrome caused by urethral calculus. A 71-year-old man had a history of urethral stenosis. He complained of bilateral leg edema and dysuria for 1 week. Physical examination revealed bilateral distention of the superficial epigastric veins, so obstruction of both common iliac veins or the inferior vena cava was suspected. Plain abdominal computed tomography showed a calculus in the pendulous urethra, distention of the bladder (as well as the right renal pelvis and ureter), and compression of the bilateral common iliac veins by the distended bladder. Iliac vein compression syndrome was diagnosed. Bilateral iliac vein compression due to bladder distention (secondary to neurogenic bladder, benign prostatic hyperplasia, or urethral calculus as in this case) is an infrequent cause of acute bilateral leg edema. Detecting distention of the superficial epigastric veins provides a clue for diagnosis of this syndrome. PMID:25802794
Singh, D R; Shrestha, S K; Shretha, S K
2004-01-01
Varicose veins afflict some 10 to 20% of the population in the west. It is believed to be less prevalent in the developing nations. Though there are absolute indications of surgery for varicose veins, people in Nepal come for treatment of the varicose veins either to join the army or to work abroad. Not all hospitals in Nepal are equipped with a vein stripper. In KMCTH, we studied 29 patients who had their long Saphenous veins stripped either with a stripper or by tunnelling around the Saphenous vein. We found that the long Saphenous vein could be stripped via the tunnelling method with an additional incision above the knee joint which is cosmetically accepted by our patients Moreover the patients were much satisfied because of minimal or no bruises in the post operative period as compared to those who had the long Saphenous vein stripped with a stripper.
Wright, Thomas C; Mossaad, Bassem M; Chummun, Shaheel; Khan, Umraz; Chapman, Thomas W L
2013-07-01
The proximally pedicled medial plantar flap is well described for coverage of wounds around the ankle and heel. This flap is usually based on the deep venae comitantes for venous drainage, with the superficial veins divided during dissection. Usually any disruption of the deep venous system of the flap would result in abandoning this choice of flap. Venous congestion is a recognised complication of medial plantar flaps. The patient described in this case report had a medial ankle defect with exposed bone, for which a proximally pedicled medial plantar flap was used. As we raised the flap, both venae comitantes of the medial planter artery were found to be disrupted. The flap was raised based on the superficial veins draining into the great saphenous, as the only system for venous drainage, with no evidence of venous congestion. The flap was successfully transposed into the defect and healed with no complications. The proximally pedicled medial plantar flap can safely rely on the superficial venous system alone for drainage. In addition, preserving the superficial veins minimise the risk of venous congestion in this flap. We recommend preservation of superficial venous system when possible. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Microchemical evidence for episodic growth of antitaxial veins during fracture-controlled fluid flow
NASA Astrophysics Data System (ADS)
Barker, Shaun L. L.; Cox, Stephen F.; Eggins, Stephen M.; Gagan, Michael K.
2006-10-01
The mechanism by which syntectonic hydrothermal veins form is widely debated, with some workers suggesting that certain vein textures are related to specific fluid flow regimes. Central to the debate is whether vein formation involves advective fluid flow, or occurs by local diffusion of material from the surrounding wall rock. To address this issue, we integrated textural observations and microchemical analyses of a hydrothermal vein from the Lachlan Orogen, southeast Australia, to reveal information about vein growth history, changes in fluid chemistry, and the evolution of fluid flow pathways during vein growth. The study area is part of a regional-scale fault-fracture network in an interbedded limestone-shale sequence, which formed at depths of ˜ 5-10 km (˜ 150-200 °C) during late Devonian crustal shortening. This integrated approach demonstrates that the zonation of textures, Sr isotopes, stable isotopes (C, O), and trace and rare earth elements is distinctly asymmetrical about the median growth-line of the vein. δ 18O values in vein calcite (17.0-18.8‰, VSMOW) are lower than those in surrounding unaltered limestones (23-25‰, VSMOW), and vary systematically across the vein. In contrast, δ 13C values are relatively constant across most of the vein, but become markedly depleted ( ca. 4‰) immediately adjacent to the wall rock. This strong depletion in δ 13C was probably caused by the influx of more oxidised fluids during the latest stages of vein growth. Strontium isotope ratios ( 87Sr/ 86Sr) vary between 0.70912 and 0.70931 across the vein. Abrubt changes in 87Sr/ 86Sr, δ 18O, Ce/Ce *, Eu/Eu * and trace element concentrations indicate that vein growth was accompanied by stepwise changes in the fluid flow pathway and consequent variations in fluid chemistry. Taken together, our findings are not consistent with growth of fibrous antitaxial veins by diffusional transfer of material from the surrounding wall rock. Instead, they suggest that externally sourced fluids migrated along episodically changing fracture-controlled flow pathways. This has implications for the dynamics of crustal permeability and mineralisation.
The Origin of Fibrous Calcite Veins: Aragonite?
NASA Astrophysics Data System (ADS)
Elburg, M. A.; Bons, P. D.
2005-12-01
Truly fibrous calcite veins occur mainly in carbonaceous shales and are characterised by high length:width ratios of their fibres (>10). Previous studies on their Sr isotopic geochemistry (Elburg et al., 2002: Geol. Soc. London Spec. Publ. 200, 103-118; Hilgers and Sindern, 2005: Geofluids, in press) have shown that some of the material could be derived from the local wall rock. These studies also showed that the veins were always enriched in Sr compared to the calcite in the host rocks. Aragonite can contain significantly more Sr than calcite, while it also tends to have a fibrous crystal habit. It is therefore possible that the fibrous habit of these veins, which now consist of calcite, are a reflection of their initial aragonitic mineralogy, rather than of any special tectonic regime during their formation. This idea was investigated by analysing the major and trace element geochemistry of selected fibrous and non-fibrous calcite veins from Arkaroola (northern Flinders Ranges, Australia). The fibrous vein analysed for major elements contains less than 1% MgCO3, whereas calcite in the host rock, with which it is in Sr isotopic equilibrium, contains 18% MgCO3. Calcite can contain significant Mg, whereas the aragonitic structure cannot accomodate this ion, so this result is consistent with the idea of an original aragonitic mineralogy of the veins. The fibrous veins show an enrichment in the middle rare earth elements (REE) compared to the calcite in the host rock and blocky veins. In a Post-Archean Average Shale normalised diagram, Eu is more strongly enriched compared to its neighbouring elements in the fibrous veins, but not in the host calcite, blocky veins, or in the silicate fraction of the host rock, suggesting more reducing conditions during fibrous vein formation. This data cannot be used as direct evidence for the fibrous veins' aragonitic mineralogy. It does, however, show that significant differences exist between calcite in host rocks, blocky and fibrous calcite veins, and this data should be incorporated in any model explaining the origin of fibrous veins.
Mohkam, Kayvan; Rode, Agnès; Darnis, Benjamin; Manichon, Anne-Frédérique; Boussel, Loïc; Ducerf, Christian; Merle, Philippe; Lesurtel, Mickaël; Mabrut, Jean-Yves
2018-05-09
The impact of portal hemodynamic variations after portal vein embolization on liver regeneration remains unknown. We studied the correlation between the parameters of hepatic venous pressure measured before and after portal vein embolization and future hypertrophy of the liver remnant after portal vein embolization. Between 2014 and 2017, we reviewed patients who were eligible for major hepatectomy and who had portal vein embolization. Patients had undergone simultaneous measurement of portal venous pressure and hepatic venous pressure gradient before and after portal vein embolization by direct puncture of portal vein and inferior vena cava. We assessed these parameters to predict future liver remnant hypertrophy. Twenty-six patients were included. After portal vein embolization, median portal venous pressure (range) increased from 15 (9-24) to 19 (10-27) mm Hg and hepatic venous pressure gradient increased from 5 (0-12) to 8 (0-14) mm Hg. Median future liver remnant volume (range) was 513 (299-933) mL before portal vein embolization versus 724 (499-1279) mL 3 weeks after portal vein embolization, representing a 35% (7.4-83.6) median hypertrophy. Post-portal vein embolization hepatic venous pressure gradient was the most accurate parameter to predict failure of future liver remnant to reach a 30% hypertrophy (c-statistic: 0.882 [95% CI: 0.727-1.000], P < 0.001). A cut-off value of post-portal vein embolization hepatic venous pressure gradient of 8 mm Hg showed a sensitivity of 91% (95% CI: 57%-99%), specificity of 80% (95% CI: 52%-96%), positive predictive value of 77% (95% CI: 46%-95%) and negative predictive value of 92.3% (95% CI: 64.0%-99.8%). On multivariate analysis, post-portal vein embolization hepatic venous pressure gradient and previous chemotherapy were identified as predictors of impaired future liver remnant hypertrophy. Post-portal vein embolization hepatic venous pressure gradient is a simple and reproducible tool which accurately predicts future liver remnant hypertrophy after portal vein embolization and allows early detection of patients who may benefit from more aggressive procedures inducing future liver remnant hypertrophy. (Surgery 2018;143:1-2.). Copyright © 2018 Elsevier Inc. All rights reserved.
Cough Recognition Based on Mel Frequency Cepstral Coefficients and Dynamic Time Warping
NASA Astrophysics Data System (ADS)
Zhu, Chunmei; Liu, Baojun; Li, Ping
Cough recognition provides important clinical information for the treatment of many respiratory diseases, but the assessment of cough frequency over a long period of time remains unsatisfied for either clinical or research purpose. In this paper, according to the advantage of dynamic time warping (DTW) and the characteristic of cough recognition, an attempt is made to adapt DTW as the recognition algorithm for cough recognition. The process of cough recognition based on mel frequency cepstral coefficients (MFCC) and DTW is introduced. Experiment results of testing samples from 3 subjects show that acceptable performances of cough recognition are obtained by DTW with a small training set.
Steato-Score: Non-Invasive Quantitative Assessment of Liver Fat by Ultrasound Imaging.
Di Lascio, Nicole; Avigo, Cinzia; Salvati, Antonio; Martini, Nicola; Ragucci, Monica; Monti, Serena; Prinster, Anna; Chiappino, Dante; Mancini, Marcello; D'Elia, Domenico; Ghiadoni, Lorenzo; Bonino, Ferruccio; Brunetto, Maurizia R; Faita, Francesco
2018-05-04
Non-alcoholic fatty liver disease is becoming a global epidemic. The aim of this study was to develop a system for assessing liver fat content based on ultrasound images. Magnetic resonance spectroscopy measurements were obtained in 61 patients and the controlled attenuation parameter in 54. Ultrasound images were acquired for all 115 participants and used to calculate the hepatic/renal ratio, hepatic/portal vein ratio, attenuation rate, diaphragm visualization and portal vein wall visualization. The Steato-score was obtained by combining these five parameters. Magnetic resonance spectroscopy measurements were significantly correlated with hepatic/renal ratio, hepatic/portal vein ratio, attenuation rate, diaphragm visualization and portal vein wall visualization; Steato-score was dependent on hepatic/renal ratio, attenuation rate and diaphragm visualization. Area under the receiver operating characteristic curve was equal to 0.98, with 89% sensitivity and 94% specificity. Controlled attenuation parameter values were significantly correlated with hepatic/renal ratio, attenuation rate, diaphragm visualization and Steato-score; the area under the curve was 0.79. This system could be a valid alternative as a non-invasive, simple and inexpensive assessment of intrahepatic fat. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.
A case of left inferior vena cava.
Yano, R; Hayakawa, D; Emura, S; Chen, H; Ozawa, Y; Taguchi, H; Shoumura, S
2001-12-01
A case of left inferior vena cava (IVC) was found in a 72-year-old male cadaver during student dissection practice in 1999 at Gifu University School of Medicine. It was formed by junction of the left and right common iliac veins at the lower left corner of the 5th lumbar vertebra. This IVC (15-mm caliber) ascended 82 mm along the left side of the abdominal aorta dorsally to the ureter. Receiving the left renal vein, it became 21 mm in caliber and ran obliquely upward for 43 mm across the abdominal aorta. As soon as it received two right renal veins at the level of the 2nd lumbar vertebra, the IVC (25-mm caliber) turned directly above. The present case belongs to Type C of the classification of McClure and Butler (1925), which is based on the combinations of the left and right IVCs, and on their location relative to the ureters. The present case also belongs to Type 1 of the classification of Yoshida et al. (1981). We consider that left IVC in the present case is mainly caused by disappearance of the right supracardinal vein and persistence of the left one during the embryological development of the IVC.
YouTube as a potential source of information on deep venous thrombosis.
Bademci, Mehmet Ş; Yazman, Serkan; Güneş, Tevfik; Ocakoglu, Gokhan; Tayfur, Kaptanderya; Gokalp, Orhan
2017-09-01
Background No work has been reported on the use of video websites to learn about deep vein thrombosis and the value of education using them. We examined the characteristics and scientific accuracy of videos related to deep vein thrombosis on YouTube. Methods YouTube was surveyed using no filter and the key words 'deep vein thrombosis' and 'leg vein clot' in June 2016. The videos evaluated were divided into three groups in terms of their scientific content, accuracy, and currency: useful, partly useful, and useless. Results Of the 1200 videos watched, 715 (59.58%) were excluded with the exclusion criteria. Although most of the videos uploaded (22.9%, n = 111) were created by physicians, the number of views for website-based videos was significantly higher (p = 0.002). When the uploaded videos were assessed in terms of their usefulness, videos from physicians and hospitals were statistically more useful than other videos (p < 0.001). Conclusions For videos created by medical professionals to be of higher quality, we believe they should be more up-to-date and comprehensive, and contain animations about treatment modalities and early diagnosis in particular.
A dynamical system that describes vein graft adaptation and failure.
Garbey, Marc; Berceli, Scott A
2013-11-07
Adaptation of vein bypass grafts to the mechanical stresses imposed by the arterial circulation is thought to be the primary determinant for lesion development, yet an understanding of how the various forces dictate local wall remodeling is lacking. We develop a dynamical system that summarizes the complex interplay between the mechanical environment and cell/matrix kinetics, ultimately dictating changes in the vein graft architecture. Based on a systematic mapping of the parameter space, three general remodeling response patterns are observed: (1) shear stabilized intimal thickening, (2) tension induced wall thinning and lumen expansion, and (3) tension stabilized wall thickening. Notable is our observation that the integration of multiple feedback mechanisms leads to a variety of non-linear responses that would be unanticipated by an analysis of each system component independently. This dynamic analysis supports the clinical observation that the majority of vein grafts proceed along an adaptive trajectory, where grafts dilate and mildly thicken in response to the increased tension and shear, but a small portion of the grafts demonstrate a maladaptive phenotype, where progressive inward remodeling and accentuated wall thickening lead to graft failure. © 2013 The Authors. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Khan, Mahasin Ali; Bera, Subir
2016-07-01
Fossil leaflet impression described here as a new species Rourea miocaudata sp. nov., showing close resemblance with the modern leaflets of Rourea caudata Planch. (Connaraceae R. Br.), has been recorded from the lower part of the Siwalik sediments (Dafla Formation, middle-upper Miocene) exposed at the road-cutting section of Pinjoli area in West Kameng district, Arunachal Pradesh. The important morphological characters of the fossil are its narrow elliptic leaflet, cuneate base, long caudate apex, entire margin, eucamptodromous to brochidodromous secondary veins, presence of intersecondary veins, percurrent and reticulate tertiary veins and orthogonally reticulate quaternary veins. This is the first authentic record of the occurrence of leaflet comparable to R. caudata of Connaraceae from the Cenozoic sediments of India and abroad. At present R. caudata does not grow in India and is restricted only in southeast Asia especially in China and Myanmar. This taxon probably migrated to these southeast Asian regions after lower Siwalik sedimentation (middle-upper Miocene) due to climatic change caused by post-Miocene orogenic movement of the Himalaya. The recovery of this species and other earlier-described evergreen taxa from the same formation, suggests the existence of a tropical, warm and humid climatic conditions during the depositional period.
Natural fracking and the genesis of five-element veins
NASA Astrophysics Data System (ADS)
Markl, Gregor; Burisch, Mathias; Neumann, Udo
2016-08-01
Hydrothermal Ag-Co-Ni-Bi-As (five-element vein type) ore deposits show very conspicuous textures of the native elements silver, bismuth, and arsenic indicating formation from a rapid, far-from-equilibrium process. Such textures include up to dm-large tree- and wire-like aggregates overgrown by Co-Ni-Fe arsenides and mostly carbonates. Despite the historical and contemporary importance of five-element vein type deposits as sources of silver, bismuth, and cobalt, and despite of spectacular museum specimens, their process of formation is not yet understood and has been a matter of debate since centuries. We propose, based on observations from a number of classical European five-element vein deposits and carbon isotope analyses, that "natural fracking," i.e., liberation of hydrocarbons or hydrocarbon-bearing fluids during break up of rocks in the vicinity of an active hydrothermal system and mixing between these hydrocarbons (e.g., methane and/or methane-bearing fluids) and a metal-rich hydrothermal fluid is responsible for ore precipitation and the formation of the unusual ore textures and assemblages. Thermodynamic and isotope mixing calculations show that the textural, chemical, and isotopic features of the investigated deposits can entirely be explained by this mechanism.
NASA Astrophysics Data System (ADS)
Linek, M.; Jungmann, M.; Berlage, T.; Clauser, C.
2005-12-01
Within the Ocean Drilling Program (ODP), image logging tools have been routinely deployed such as the Formation MicroScanner (FMS) or the Resistivity-At-Bit (RAB) tools. Both logging methods are based on resistivity measurements at the borehole wall and therefore are sensitive to conductivity contrasts, which are mapped in color scale images. These images are commonly used to study the structure of the sedimentary rocks and the oceanic crust (petrologic fabric, fractures, veins, etc.). So far, mapping of lithology from electrical images is purely based on visual inspection and subjective interpretation. We apply digital image analysis on electrical borehole wall images in order to develop a method, which augments objective rock identification. We focus on supervised textural pattern recognition which studies the spatial gray level distribution with respect to certain rock types. FMS image intervals of rock classes known from core data are taken in order to train textural characteristics for each class. A so-called gray level co-occurrence matrix is computed by counting the occurrence of a pair of gray levels that are a certain distant apart. Once the matrix for an image interval is computed, we calculate the image contrast, homogeneity, energy, and entropy. We assign characteristic textural features to different rock types by reducing the image information into a small set of descriptive features. Once a discriminating set of texture features for each rock type is found, we are able to discriminate the entire FMS images regarding the trained rock type classification. A rock classification based on texture features enables quantitative lithology mapping and is characterized by a high repeatability, in contrast to a purely visual subjective image interpretation. We show examples for the rock classification between breccias, pillows, massive units, and horizontally bedded tuffs based on ODP image data.
Lozano-Diez, Alicia; Zazo, Ruben; Toledano, Doroteo T; Gonzalez-Rodriguez, Joaquin
2017-01-01
Language recognition systems based on bottleneck features have recently become the state-of-the-art in this research field, showing its success in the last Language Recognition Evaluation (LRE 2015) organized by NIST (U.S. National Institute of Standards and Technology). This type of system is based on a deep neural network (DNN) trained to discriminate between phonetic units, i.e. trained for the task of automatic speech recognition (ASR). This DNN aims to compress information in one of its layers, known as bottleneck (BN) layer, which is used to obtain a new frame representation of the audio signal. This representation has been proven to be useful for the task of language identification (LID). Thus, bottleneck features are used as input to the language recognition system, instead of a classical parameterization of the signal based on cepstral feature vectors such as MFCCs (Mel Frequency Cepstral Coefficients). Despite the success of this approach in language recognition, there is a lack of studies analyzing in a systematic way how the topology of the DNN influences the performance of bottleneck feature-based language recognition systems. In this work, we try to fill-in this gap, analyzing language recognition results with different topologies for the DNN used to extract the bottleneck features, comparing them and against a reference system based on a more classical cepstral representation of the input signal with a total variability model. This way, we obtain useful knowledge about how the DNN configuration influences bottleneck feature-based language recognition systems performance.
A sensor and video based ontology for activity recognition in smart environments.
Mitchell, D; Morrow, Philip J; Nugent, Chris D
2014-01-01
Activity recognition is used in a wide range of applications including healthcare and security. In a smart environment activity recognition can be used to monitor and support the activities of a user. There have been a range of methods used in activity recognition including sensor-based approaches, vision-based approaches and ontological approaches. This paper presents a novel approach to activity recognition in a smart home environment which combines sensor and video data through an ontological framework. The ontology describes the relationships and interactions between activities, the user, objects, sensors and video data.
Free Flap Survival Despite Internal Jugular Vein Thrombosis in Head and Neck Reconstruction
Kiya, Koichiro; Seike, Shien; Hosokawa, Ko
2018-01-01
Summary: Microvascular free tissue transfer is one of the most common techniques of reconstruction for complex head and neck surgical defects. Generally, venous thrombosis is more likely to occur than arterial thrombosis in vascular anastomosis. Thus, recipient veins must be chosen carefully. Although the internal jugular vein is preferred as a recipient vein by many microsurgeons, internal jugular vein thrombosis is a potential complication, as shown in our report. Therefore, we consider that the external jugular vein still is an option as a recipient for venous anastomosis and that it is better to perform multiple vein anastomoses with 2 different venous systems, such as the internal and external jugular systems, than anastomoses within the same venous system. PMID:29464172
... and where it travels. A clot in a deep vein This is known as deep vein thrombosis (DVT). Deep vein thrombosis may not cause any symptoms. If ... as a pulmonary embolism, this occurs when a deep vein clot breaks free and travels through the ...
Intravitreal triamcinolone acetonide injections in the treatment of retinal vein occlusions.
Roth, Daniel B; Cukras, Catherine; Radhakrishnan, Ravi; Feuer, William J; Yarian, David L; Green, Stuart N; Wheatley, Harold M; Prenner, Jonathan
2008-01-01
To report the visual acuity response after intravitreal triamcinolone injection in patients with macular edema due to retinal vein occlusions. Retrospective nonrandomized interventional series of 172 consecutive patients with macular edema due to retinal vein occlusions who were treated with intravitreal triamcinolone acetonide injection. Patients underwent Snellen visual acuity testing and ophthalmoscopic examination at baseline and 1, 3, 6, and 12 months after intravitreal triamcinolone acetonide injection. All subtypes of retinal vein occlusions showed significant improvements in mean visual acuity 1 month after injection. This improvement in visual acuity was maintained over the 12-month period for all but the central retinal vein occlusion group. Seventy-one (41.3%) of the 172 patients received more than one intravitreal triamcinolone injection for unresolved or recurrent macular edema. This study demonstrates a benefit associated with intravitreal triamcinolone acetonide injection for retinal vein occlusions that was maintained by patients with branch retinal vein occlusions and hemiretinal vein occlusions over a 12-month period. Visual acuity improvement was not maintained in patients with central retinal vein occlusions with this course of treatment.
Vascular anatomy of canine hepatic venous system: a basis for liver surgery.
Mari, L; Acocella, F
2015-06-01
Detailed knowledge of the vascular anatomy is important for improving surgical approaches to the liver. Twelve canine livers were skeletonized to describe the anatomy of their portal and hepatic veins in details. Our data suggest that the liver can be divided into two sections, three divisions, seven lobes and two to four sub-lobes. This differs from the classic division into four lobes, four sub-lobes and two processes. The right section was perfused by the right portal branch and drained by independent hepatic veins, while most of the left section, perfused by the left portal branch, was drained by the main hepatic vein deriving from the middle and the left hepatic vein confluence. Part of the right medial lobe, and in some cases the papillary process of the caudate lobe, drained directly into the caudal vena cava. A proper right hepatic vein draining blood from more than one lobe was never observed. Portal connections between the quadrate and the left medial lobe were frequently recorded. Two sub-lobes with different portal blood supply and venous drainage could be identified in the right lateral (33.3% of cases) and the left lateral (100% of cases) lobes. From our results, the classic nomenclature of the liver lobes does not reflect their vascularization. Based on similarities between canine lobes and human segments, a new nomenclature is possible and may be less confounding in surgical settings. © 2014 Blackwell Verlag GmbH.
Filaire, Marc; Nohra, Olivier; Sakka, Laurent; Chadeyras, Jean Baptiste; Da Costa, Valence; Naamee, Adel; Bailly, Patrick; Escande, Georges
2008-06-01
The interatrial septum (IAS) can be dissected to resect pulmonary tumors invading the left atrium. The aim of this study was to describe the dissected structures, and to expose the benefits, the limits, and the embryologic reasons of such dissection. We dissected the IAS of 11 fresh, non-embalmed human hearts. The dissected structures were described and the length and depth of the dissection were measured. A histological study was performed in four other fresh hearts to identify and differentiate between dissectible and non-dissectible structures. The dissection was performed through a fatty tissue located between two muscular walls. The depth limit of the IAS dissection was identified as the limbus of the fossa ovalis and the muscular roof of the atria. The section of the latter doubles the depth of the dissection at the level of the upper pulmonary veins. Mean length of the dissected IAS was 77 mm (55-90). Mean depths of the IAS were 41 mm (35-50) at the level of the left upper pulmonary vein, 27 mm (12-35) between the upper and lower pulmonary veins, and 14 mm (8-20) at the level of the left inferior pulmonary vein The surgical dissection of the IAS is performed through the septum secundum that appears as an infold of the atrial wall. The length of the resectable left atrial cuff reaches a mean of 40 mm at the level of the upper pulmonary vein.
NASA Astrophysics Data System (ADS)
Lahiri, B. B.; Bagavathiappan, S.; Nishanthi, K.; Mohanalakshmi, K.; Veni, L.; Saumya; Yacin, S. M.; Philip, John
2016-05-01
Thermoregulatory control of blood flow plays an important role in maintaining the human body temperature and it provides physiological resistance against extreme environmental thermal stresses. To understand the role of age on thermal signals from veins and the thermoregulatory mechanism, the dynamic variation of the vein temperature on the hands of 17 human subjects, under a localized cold stress, was studied using infrared thermography. It was observed that the vein temperature of the stimulated hand initially decreased with time up to a time interval (called 'inversion time'), which was attributed to the localized cutaneous vasoconstriction. Beyond inversion time, a rise in the vein temperature of the stimulated hand was observed. A shift in the inversion time to higher values was observed for the older subjects, which was attributed to the reduced efficiency and responsiveness of the cutaneous vasoconstriction mechanism in these subjects. Our studies indicated that the inversion time increased linearly with subject age with strong positive Pearson's correlation coefficient of 0.94. It was also observed that the contralateral symmetry in vasoconstriction was much lower in older subjects than the younger subjects. The absolute difference between the left and right inversion time varied between 11-118 s and 5-28 s for the older and younger subjects, respectively. Our study clearly demonstrated that infrared thermography is one of the most effective experimental tool for studying dynamic variation in vein pixel temperature under localized thermal stresses.
González-Suárez, Ana; Trujillo, Macarena; Burdío, Fernando; Andaluz, Anna; Berjano, Enrique
2014-08-01
To assess by means of computer simulations whether the heat sink effect inside a large vessel (portal vein) could protect the vessel wall from thermal damage close to an internally cooled electrode during radiofrequency (RF)-assisted resection. First,in vivo experiments were conducted to validate the computational model by comparing the experimental and computational thermal lesion shapes created around the vessels. Computer simulations were then carried out to study the effect of different factors such as device-tissue contact, vessel position, and vessel-device distance on temperature distributions and thermal lesion shapes near a large vessel, specifically the portal vein. The geometries of thermal lesions around the vessels in the in vivo experiments were in agreement with the computer results. The thermal lesion shape created around the portal vein was significantly modified by the heat sink effect in all the cases considered. Thermal damage to the portal vein wall was inversely related to the vessel-device distance. It was also more pronounced when the device-tissue contact surface was reduced or when the vessel was parallel to the device or perpendicular to its distal end (blade zone), the vessel wall being damaged at distances less than 4.25 mm. The computational findings suggest that the heat sink effect could protect the portal vein wall for distances equal to or greater than 5 mm, regardless of its position and distance with respect to the RF-based device.
... impaired kidney (renal) function should be given special consideration before receiving iodine-based contrast materials by vein or artery. Such patients are at risk for developing contrast-induced nephropathy, ...
Exogenous temporal cues enhance recognition memory in an object-based manner.
Ohyama, Junji; Watanabe, Katsumi
2010-11-01
Exogenous attention enhances the perception of attended items in both a space-based and an object-based manner. Exogenous attention also improves recognition memory for attended items in the space-based mode. However, it has not been examined whether object-based exogenous attention enhances recognition memory. To address this issue, we examined whether a sudden visual change in a task-irrelevant stimulus (an exogenous cue) would affect participants' recognition memory for items that were serially presented around a cued time. The results showed that recognition accuracy for an item was strongly enhanced when the visual cue occurred at the same location and time as the item (Experiments 1 and 2). The memory enhancement effect occurred when the exogenous visual cue and an item belonged to the same object (Experiments 3 and 4) and even when the cue was counterpredictive of the timing of an item to be asked about (Experiment 5). The present study suggests that an exogenous temporal cue automatically enhances the recognition accuracy for an item that is presented at close temporal proximity to the cue and that recognition memory enhancement occurs in an object-based manner.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Checco, James W.; Kreitler, Dale F.; Thomas, Nicole C.
Peptide-based agents derived from well-defined scaffolds offer an alternative to antibodies for selective and high-affinity recognition of large and topologically complex protein surfaces. In this paper, we describe a strategy for designing oligomers containing both α- and β-amino acid residues (“α/β-peptides”) that mimic several peptides derived from the three-helix bundle “Z-domain” scaffold. We show that α/β-peptides derived from a Z-domain peptide targeting vascular endothelial growth factor (VEGF) can structurally and functionally mimic the binding surface of the parent peptide while exhibiting significantly decreased susceptibility to proteolysis. The tightest VEGF-binding α/β-peptide inhibits the VEGF 165-induced proliferation of human umbilical vein endothelialmore » cells. We demonstrate the versatility of this strategy by showing how principles underlying VEGF signaling inhibitors can be rapidly extended to produce Z-domain–mimetic α/β-peptides that bind to two other protein partners, IgG and tumor necrosis factor-α. Because well-established selection techniques can identify high-affinity Z-domain derivatives from large DNA-encoded libraries, our findings should enable the design of biostable α/β-peptides that bind tightly and specifically to diverse targets of biomedical interest. Finally, such reagents would be useful for diagnostic and therapeutic applications.« less
Innate lymphoid cells in tissue homeostasis and diseases.
Ignacio, Aline; Breda, Cristiane Naffah Souza; Camara, Niels Olsen Saraiva
2017-08-18
Innate lymphoid cells (ILCs) are the most recently discovered family of innate immune cells. They are a part of the innate immune system, but develop from the lymphoid lineage. They lack pattern-recognition receptors and rearranged receptors, and therefore cannot directly mediate antigen specific responses. The progenitors specifically associated with the ILCs lineage have been uncovered, enabling the distinction between ILCs and natural killer cells. Based on the requirement of specific transcription factors and their patterns of cytokine production, ILCs are categorized into three subsets (ILC1, ILC2 and ILC3). First observed in mucosal surfaces, these cell populations interact with hematopoietic and non-hematopoietic cells throughout the body during homeostasis and diseases, promoting immunity, commensal microbiota tolerance, tissue repair and inflammation. Over the last 8 years, ILCs came into the spotlight as an essential cell type able to integrate diverse host immune responses. Recently, it became known that ILC subsets play a key role in immune responses at barrier surfaces, interacting with the microbiota, nutrients and metabolites. Since the liver receives the venous blood directly from the intestinal vein, the intestine and liver are essential to maintain tolerance and can rapidly respond to infections or tissue damage. Therefore, in this review, we discuss recent findings regarding ILC functions in homeostasis and disease, with a focus on the intestine and liver.
Checco, James W.; Kreitler, Dale F.; Thomas, Nicole C.; ...
2015-03-30
Peptide-based agents derived from well-defined scaffolds offer an alternative to antibodies for selective and high-affinity recognition of large and topologically complex protein surfaces. In this paper, we describe a strategy for designing oligomers containing both α- and β-amino acid residues (“α/β-peptides”) that mimic several peptides derived from the three-helix bundle “Z-domain” scaffold. We show that α/β-peptides derived from a Z-domain peptide targeting vascular endothelial growth factor (VEGF) can structurally and functionally mimic the binding surface of the parent peptide while exhibiting significantly decreased susceptibility to proteolysis. The tightest VEGF-binding α/β-peptide inhibits the VEGF 165-induced proliferation of human umbilical vein endothelialmore » cells. We demonstrate the versatility of this strategy by showing how principles underlying VEGF signaling inhibitors can be rapidly extended to produce Z-domain–mimetic α/β-peptides that bind to two other protein partners, IgG and tumor necrosis factor-α. Because well-established selection techniques can identify high-affinity Z-domain derivatives from large DNA-encoded libraries, our findings should enable the design of biostable α/β-peptides that bind tightly and specifically to diverse targets of biomedical interest. Finally, such reagents would be useful for diagnostic and therapeutic applications.« less
Mettler, John; Al-Katib, Sayf
2018-06-07
Renal angiomyolipoma (AML) is the most commonly encountered mesenchymal tumor of the kidney which can present spontaneously or in association with tuberous sclerosis complex. Rarely, renal AMLs may demonstrate aggressive features such as renal vein invasion. This common entity and its uncommon complications are diagnosed based on physical examination and computed tomography results. Here we report imaging findings of a renal AML with renal vein and inferior vena cava invasion resulting in pulmonary tumor embolus and pulmonary infarction. Copyright © 2018. Published by Elsevier Inc.
Gómez-Ulla, F; Abraldes, M J; Basauri, E; Fernández, M; García-Layana, A; Gili, P; Montero, J; Nadal, J; Morales, V; Saravia, M; Cabrera, F; Cervera, E
2010-09-01
A guidelines for the management of retinal vein occlusion is presented. This is necessary because at this moment several therapeutic alternatives have been developed although their role is not yet sufficiently defined. Review of the literature for evidence published up to date. Relevant literature was identified and the level of evidence graded. Evidence was then assessed for consistency, applicability and clinical impact. The information was contrasted with those guides published in other countries. Taking into account the different options of treatment that are currently used, several modes of action are suggested. The role of the various complementary examinations are discussed and it is recommended that criteria for the treatment are based on clinical, angiographic, and tomographic findings. Although there is no overall consensus, these guidelines promote a good standard of clinical practise and provide an update of the management of retinal vein occlusion. Copyright © 2010. Published by Elsevier Espana.
Nowlan, G.A.; Gerstel, W.J.
1985-01-01
The study area is bounded by several areas of known mineralization (Hedl und and others, 1983). Vein and bedding replacement deposits of silver, zinc, and lead were mined from 1890 until about 1918 in the vicinity of Weston Pass (map A), on the northeastern border of the study area. Gold and silver were mined from about 1860 until about 1880 from veins in the Granite area (map A), on the northwestern border of the study area; minor prospecting activity continues today. From 1935 to 1937, veins of gold, silver, and base metals were mined in the vicinity of Fourmile Creek, on the southwestern border of the study area (map A). Recently, active uranium prospecting has been taking place in the vicinity of the Middle Fork of Salt Creek, on the southeastern border of the study area (map A).
Diagnosis and Treatment of Lower Extremity Deep Vein Thrombosis: Korean Practice Guidelines
Min, Seung-Kee; Kim, Young Hwan; Joh, Jin Hyun; Kang, Jin Mo; Park, Ui Jun; Kim, Hyung-Kee; Chang, Jeong-Hwan; Park, Sang Jun; Kim, Jang Yong; Bae, Jae Ik; Choi, Sun Young; Kim, Chang Won; Park, Sung Il; Yim, Nam Yeol; Jeon, Yong Sun; Yoon, Hyun-Ki; Park, Ki Hyuk
2016-01-01
Lower extremity deep vein thrombosis is a serious medical condition that can result in death or major disability due to pulmonary embolism or post-thrombotic syndrome. Appropriate diagnosis and treatment are required to improve symptoms and salvage the affected limb. Early thrombus clearance rapidly resolves symptoms related to venous obstruction, restores valve function and reduces the incidence of post-thrombotic syndrome. Recently, endovascular treatment has been established as a standard method for early thrombus removal. However, there are a variety of views regarding the indications and procedures among medical institutions and operators. Therefore, we intend to provide evidence-based guidelines for diagnosis and treatment of lower extremity deep vein thrombosis by multidisciplinary consensus. These guidelines are the result of a close collaboration between interventional radiologists and vascular surgeons. The goals of these guidelines are to improve treatment, to serve as a guide to the clinician, and consequently to contribute to public health care. PMID:27699156
ERIC Educational Resources Information Center
Broder, Arndt; Schutz, Julia
2009-01-01
Recent reviews of recognition receiver operating characteristics (ROCs) claim that their curvilinear shape rules out threshold models of recognition. However, the shape of ROCs based on confidence ratings is not diagnostic to refute threshold models, whereas ROCs based on experimental bias manipulations are. Also, fitting predicted frequencies to…
Nephrotic Syndrome Associated with Renal Vein Thrombosis
Kang, Sung Kyew; Park, Sung Kwang
1987-01-01
The coexistence of nephrotic syndrome and renal vein thrombosis has been of medical interest since Rayer’s description in 1840. Renal vein thrombosis has been underdiagnosed because of its variable clinical and radiological findings but it becomes a more frequently recognizable clinical entity since diagnosis can be easily established by modern angiographic techniques. Generally it has been believed that renal vein thrombosis may cause nephrotic syndrome. But recent articles strongly suggest that renal vein thrombosis is a complication of the nephrotic syndrome rather than a cause. We report three cases of nephrotic syndrome associated with renal vein thrombosis. PMID:3154812
Caringella, Marissa A; Bongers, Franca J; Sack, Lawren
2015-12-01
Leaf venation is diverse across plant species and has practical applications from paleobotany to modern agriculture. However, the impact of vein traits on plant performance has not yet been tested in a model system such as Arabidopsis thaliana. Previous studies analysed cotyledons of A. thaliana vein mutants and identified visible differences in their vein systems from the wild type (WT). We measured leaf hydraulic conductance (Kleaf ), vein traits, and xylem and mesophyll anatomy for A. thaliana WT (Col-0) and four vein mutants (dot3-111 and dot3-134, and cvp1-3 and cvp2-1). Mutant true leaves did not possess the qualitative venation anomalies previously shown in the cotyledons, but varied quantitatively in vein traits and leaf anatomy across genotypes. The WT had significantly higher mean Kleaf . Across all genotypes, there was a strong correlation of Kleaf with traits related to hydraulic conductance across the bundle sheath, as influenced by the number and radial diameter of bundle sheath cells and vein length per area. These findings support the hypothesis that vein traits influence Kleaf , indicating the usefulness of this mutant system for testing theory that was primarily established comparatively across species, and supports a strong role for the bundle sheath in influencing Kleaf . © 2015 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Fagereng, Åke
2011-05-01
A well developed fault-fracture mesh is observed in the Chrystalls Beach Complex, an accretionary mélange within the Otago Schist on the South Island of New Zealand. In this study, an analysis of vein thicknesses and clustering of veins is presented. Both shear and extension veins have a power-law thickness distribution. Measures of vein spacing best fit a power-law distribution, but a small data set limits this interpretation to a small fractal range. Vein clustering varies from random to moderately clustered between outcrops, and is the greatest where a large proportion of relatively competent blocks occurs within the mélange. Fractures are distributed within the mélange matrix, and this localized deformation requires heterogeneity in rheology and/or fluid pressure distribution, whereas pervasive, distributed deformation occurs in relatively homogeneous rock. The overall trend of this deformation being mainly accommodated by thin veins required that new fractures formed preferentially over refracturing existing veins, which highlights the distributed nature of deformation within a fault-fracture mesh. The predominance of new fractures may result from vein material being stronger than the cleaved wall rock, such that wall rock failure occurred instead of reopening of pre-existing shear and extension veins.
NASA Astrophysics Data System (ADS)
Torremans, Koen; Muchez, Philippe; Sintubin, Manuel
2014-12-01
Flexural flow is thought unlikely to occur in naturally deformed, competent isotropic single-layers. In this study we discuss a particular case of folded bedding-parallel fibrous dolomite veins in shale, in which the internal strain pattern and microstructural deformation features provide new insights in the mechanisms enabling flexural flow folding. Strain in the pre-folding veins is accommodated by two main mechanisms: intracrystalline deformation by bending and intergranular deformation with bookshelf rotation of dolomite fibres. The initially orthogonal dolomite fibres allowed a reconstruction of the strain distribution across the folded veins. This analysis shows that the planar mechanical anisotropy created by the fibres causes the veins to approximate flexural flow. During folding, synkinematic veins overgrow the pre-folding fibrous dolomite veins. Microstructures and dolomite growth morphologies reflect growth during progressive fold evolution, with evidence for flexural slip at fold lock-up. Homogeneous flattening, as evidenced by disjunctive axial-planar cleavage, subsequently modified these folds from class 1B to 1C folds. Our study shows that the internal vein fabric has a first-order influence on folding kinematics. Moreover, the fibrous dolomite veins show high viscosity contrasts with the shale matrix, essential in creating transient permeability for subsequent mineralising stages in the later synkinematic veins during progressive folding.
Cavernous Transformation of Portal Vein Secondary to Portal Vein Thrombosis: A Case Report
Ramos, Radhames; Park, Yoojin; Shazad, Ghulamullah; A.Garcia, Christine; Cohen, Ronny
2012-01-01
There are few reported cases of cavernous transformation of the portal vein (CTPV) in adults. We present a case of a 58 year-old male who was found to have this complication due to portal vein thrombosis (PVT). A 58-year old African American male with chronic alcohol and tobacco use presented with a 25-day history of weakness, generalized malaise, nausea and vomiting associated with progressively worsening anorexia and weight loss. The patient was admitted for severe anemia in conjunction with abnormal liver function tests and electrolyte abnormalities, and to rule out end stage liver disease or hepatic malignancy. The work-up for anemia showed no significant colon abnormalities, cholecystitis, liver cirrhosis, or liver abnormalities but could not rule out malignancy. An esophageogastroduodenoscopy (EGD) was suspicious for a mass compressing the stomach and small bowel. After further work-up, the hepatic mass has been diagnosed as a cavernous transformation of the portal vein (CTPV), a very rare complication of portal vein thrombosis (PVT). Cavernous Transformation of the Portal Vein (CTPV) is a rare and incurable complication of portal vein thrombosis (PVT) that should be considered as one of the differential diagnoses of a hepatic mass. Keywords Cavernous transformation of the portal vein; Portal vein thrombosis; Portal hypertension; Hyperbilirubinemia; Hepatic mass PMID:22383935
Krishnamoorthy, Bhuvaneswari; Critchley, William R.; Thompson, Alexander J.; Payne, Katherine; Morris, Julie; Venkateswaran, Rajamiyer V.; Caress, Ann L.
2018-01-01
Background Current consensus statements maintain that endoscopic vein harvesting (EVH) should be standard care in coronary artery bypass graft surgery, but vein quality and clinical outcomes have been questioned. The VICO trial (Vein Integrity and Clinical Outcomes) was designed to assess the impact of different vein harvesting methods on vessel damage and whether this contributes to clinical outcomes after coronary artery bypass grafting. Methods In this single-center, randomized clinical trial, patients undergoing coronary artery bypass grafting with an internal mammary artery and with 1 to 4 vein grafts were recruited. All veins were harvested by a single experienced practitioner. We randomly allocated 300 patients into closed tunnel CO2 EVH (n=100), open tunnel CO2 EVH (n=100), and traditional open vein harvesting (n=100) groups. The primary end point was endothelial integrity and muscular damage of the harvested vein. Secondary end points included clinical outcomes (major adverse cardiac events), use of healthcare resources, and impact on health status (quality-adjusted life-years). Results The open vein harvesting group demonstrated marginally better endothelial integrity in random samples (85% versus 88% versus 93% for closed tunnel EVH, open tunnel EVH, and open vein harvesting; P<0.001). Closed tunnel EVH displayed the lowest longitudinal hypertrophy (1% versus 13.5% versus 3%; P=0.001). However, no differences in endothelial stretching were observed between groups (37% versus 37% versus 31%; P=0.62). Secondary clinical outcomes demonstrated no significant differences in composite major adverse cardiac event scores at each time point up to 48 months. The quality-adjusted life-year gain per patient was 0.11 (P<0.001) for closed tunnel EVH and 0.07 (P=0.003) for open tunnel EVH compared with open vein harvesting. The likelihood of being cost-effective, at a predefined threshold of £20 000 per quality-adjusted life-year gained, was 75% for closed tunnel EVH, 19% for open tunnel EVH, and 6% for open vein harvesting. Conclusions Our study demonstrates that harvesting techniques affect the integrity of different vein layers, albeit only slightly. Secondary outcomes suggest that histological findings do not directly contribute to major adverse cardiac event outcomes. Gains in health status were observed, and cost-effectiveness was better with closed tunnel EVH. High-level experience with endoscopic harvesting performed by a dedicated specialist practitioner gives optimal results comparable to those of open vein harvesting. Clinical Trial Registration URL: https://www.isrctn.com. International Standard Randomised Controlled Trial Registry Number: 91485426. PMID:28637880
Influence of vein fabric on strain distribution and fold kinematics
NASA Astrophysics Data System (ADS)
Torremans, Koen; Muchez, Philippe; Sintubin, Manuel
2014-05-01
Abundant pre-folding, bedding-parallel fibrous dolomite veins in shale are found associated with the Nkana-Mindola stratiform Cu-Co deposit in the Central African Copperbelt, Zambia. These monomineralic veins extend for several meters along strike, with a fibrous infill orthogonal to low-tortuosity vein walls. Growth morphologies vary from antitaxial with a pronounced median surface to asymmetric syntaxial, always with small but quantifiable growth competition. Subsequently, these veins were folded. In this study, we aim to constrain the kinematic fold mechanism by which strain is accommodated in these veins, estimate paleorheology at time of deformation and investigate the influence of vein fabric on deformation during folding. Finally, the influence of the deformation on known metallogenetic stages is assessed. Various deformation styles are observed, ultimately related to vein attitude across tight to close lower-order, hectometre-scale folds. In fold hinges, at low to average dips, veins are (poly-)harmonically to disharmonically folded as parasitic folds in single or multilayer systems. With increasing distance from the fold hinge, parasitic fold amplitude decreases and asymmetry increases. At high dips in the limbs, low-displacement duplication thrusts of veins at low angles to bedding are abundant. Slickenfibres and slickenlines are sub-perpendicular to fold hinges and shallow-dipping slickenfibre-step lineations are parallel to local fold hinge lines. A dip isogon analysis of reconstructed fold geometries prior to homogeneous shortening reveals type 1B parallel folds for the veins and type 1C for the matrix. Two main deformation mechanisms are identified in folded veins. Firstly, undulatory extinction, subgrains and fluid inclusions planes parallel the fibre long axis, with deformation intensity increasing away from the fold hinges, indicate intracrystalline strain accumulation. Secondly, intergranular deformation through bookshelf rotation of fibres, via collective parallel rotation of fibres and shearing along fibre grain boundaries, is clearly observed under cathodoluminescence. We analysed the internal strain distribution by quantifying simple shear strain caused by deflection of the initially orthogonal fibres relative to layer inclination at a given position across the fold. Shear angle, and thus shear strain, steadily increases towards the limbs away from the fold hinge. Comparison of observed shear strain to theoretical distribution for kinematic mechanisms, amongst other lines of evidence, clearly points to pure flexural flow followed by homogeneous shortening. As flexural flow is not the expected kinematic folding mechanism for competent layers in an incompetent shale matrix, our analysis shows that the internal vein fabric in these dolomite veins can exhibit a first-order influence on folding mechanisms. In addition, quantitative analysis shows that these veins acted as rigid objects with high viscosity contrast relative to the incompetent carbonaceous shale, rather than as semi-passive markers. Later folding-related syn-orogenic veins, intensely mineralised with Cu-Co sulphides, are strongly related to deformation of these pre-folding veins. The high viscosity contrast created by the pre-folding fibrous dolomite veins was therefore essential in creating transient permeability for subsequent mineralising stages in the veining history.
Appearance-Based Facial Recognition Using Visible and Thermal Imagery: A Comparative Study
2006-01-01
Appearance-Based Facial Recognition Using Visible and Thermal Imagery: A Comparative Study ∗ Andrea Selinger† Diego A. Socolinsky‡ †Equinox...TYPE 3. DATES COVERED 00-00-2006 to 00-00-2006 4. TITLE AND SUBTITLE Appearance-Based Facial Recognition Using Visible and Thermal Imagery: A
Navarro, T P; Nunes, T A; Ribeiro, A L; Castro-Silva, M
2009-02-01
Chronic venous insufficiency ranges from mild telangiectasias to skin ulceration with poor prognosis regarding healing and quality of life. Varicose veins are the most frequent clinical presentation, affecting 75% of such patients and 71% are due to primary reflux of great saphenous vein, which is the most compromised vein in chronic venous insufficiency. However, about 75% of these veins are not dilated. The standard treatment has been stripping of the saphenous vein, because it has 85% of good results at long term. However, saphenous vein is the main arterial substitute and should be spared whenever possible. The development of non-invasive diagnostic methods showed that hemodynamic worsening correlates with clinical severity and that the majority of patients did not have a dilated saphenous vein. Thus, several selective operations proposed to spare the saphenous vein have reported good results. Minimally invasive techniques (eco-guided foam, radiofrequency and laser) have also emerged aiming to obliterate the vein and abolishing reflux and have also reported good results, but they do not spare the vessel. Measurement of saphenous diameter has been shown to correlate with clinical and hemodynamic worsening, thus allowing planning the invasive treatment of chronic venous insufficiency. Dilated diameters (>7.2 mm) correlate with severe disease and poor prognosis, being an indication for total abolishment of saphenous vein reflux. All other presentations must be individualized, sparing saphenous vein whenever possible and and a standardized approach is not indicated for all patients.
Automated detection of periventricular veins on 7 T brain MRI
NASA Astrophysics Data System (ADS)
Kuijf, Hugo J.; Bouvy, Willem H.; Zwanenburg, Jaco J. M.; Viergever, Max A.; Biessels, Geert Jan; Vincken, Koen L.
2015-03-01
Cerebral small vessel disease is common in elderly persons and a leading cause of cognitive decline, dementia, and acute stroke. With the introduction of ultra-high field strength 7.0T MRI, it is possible to visualize small vessels in the brain. In this work, a proof-of-principle study is conducted to assess the feasibility of automatically detecting periventricular veins. Periventricular veins are organized in a fan-pattern and drain venous blood from the brain towards the caudate vein of Schlesinger, which is situated along the lateral ventricles. Just outside this vein, a region-of- interest (ROI) through which all periventricular veins must cross is defined. Within this ROI, a combination of the vesselness filter, tubular tracking, and hysteresis thresholding is applied to locate periventricular veins. All detected locations were evaluated by an expert human observer. The results showed a positive predictive value of 88% and a sensitivity of 95% for detecting periventricular veins. The proposed method shows good results in detecting periventricular veins in the brain on 7.0T MR images. Compared to previous works, that only use a 1D or 2D ROI and limited image processing, our work presents a more comprehensive definition of the ROI, advanced image processing techniques to detect periventricular veins, and a quantitative analysis of the performance. The results of this proof-of-principle study are promising and will be used to assess periventricular veins on 7.0T brain MRI.
Clinical anatomy related to the hepatic veins for right lobe living donor liver transplantation.
Liu, Jing; Chen, Da-Feng; Chen, Wen-You; Guo, Hua; Li, Zhong-Hua
2013-05-01
The complexity of liver reconstruction has limited partial right lobe living donor liver transplantation. It is largely due to the difficulty of dealing with the middle hepatic vein. We sought to define the anatomic features of hepatic veins. Forty-one fresh adult livers, 43 formalin-fixed adult cadaver livers, and 91 adult liver corrosion casts were used for the study. We determined the number of branches, the maximum diameter, the whole length, the extrahepatic length of the hepatic veins, and the deviation of the middle hepatic vein from the main portal fissure. Nakamura and Tsuzuki's classification of hepatic vein types was used. Type A, B, and C accounted for 59.4, 27.8, and 12.8% of all specimens in this study, respectively. The middle and left hepatic veins formed a common trunk in 60.3% of the specimens, and the length of the common trunk was 1.12 ± 0.62 cm. The degree of deviation to the right of the middle hepatic vein from the main portal fissure was 14.11° ± 12.65°. The frequency of hepatic vein types and the degree of deviation to the right of the middle hepatic vein in this study is markedly different from that reported in other literature. The anatomic features of the hepatic veins in this study suggest that right lobe living donor liver transplantation is more suitable for Chinese. Copyright © 2012 Wiley Periodicals, Inc.
Onishi, Yasuyuki; Kimura, Hiroyuki; Kanagaki, Mitsunori; Oka, Shojiro; Fukumoto, Genki; Otani, Tomoaki; Matsubara, Naoko; Kawabata, Kazuna; Namikawa, Mio; Matsumura, Takeshi; Kimura, Toshiyuki
2018-04-23
A 48-year-old woman with alcoholic liver cirrhosis was admitted to our hospital because of hematochezia and severe anemia. She had been hospitalized many times over the past year for hematochezia of unknown etiology. Contrast-enhanced CT demonstrated ileal varices, which were fed by several ileal veins. These feeding veins were selectively embolized with N-butyl cyanoacrylate (NBCA) via a recanalized paraumbilical vein. The paraumbilical vein instead of the portal vein was punctured to decrease the risk of bleeding complications because she had coagulopathy and ascites. We consider antegrade embolization of ileal varices with NBCA to be a feasible and effective treatment. Access via a paraumbilical vein is an alternative to the transhepatic approach.Level of Evidence Level V, case report.
Kim, Hyoung Ook; Kim, Jae Kyu; Park, Jin Gyoon; Yim, Nam Yeol; Kang, Yang Jun; Jung, Hye Doo
2016-01-01
PURPOSE We aimed to evaluate the efficiency of placing an inferior vena cava (IVC) filter through the same popliteal vein access site used for percutaneous endovenous intervention in patients with extensive lower extremity deep vein thrombosis. METHODS This retrospective study included 21 patients who underwent IVC filter insertion through the popliteal vein over a three-year period. Patient medical records were reviewed for the location of the deep vein thrombosis, result of filter removal, and total number of endovascular procedures needed for filter insertion and recanalization of the lower extremity venous system. Follow-up lower extremity computed tomography (CT) venography was also reviewed in each patient to assess the degree of filter tilt in the IVC. RESULTS All patients had extensive lower extremity deep vein thrombosis involving the iliac vein and/or femoral vein. Seventeen patients showed deep vein thrombosis of the calf veins. In all patients, IVC filter insertion and the recanalization procedure were performed during a single procedure through the single popliteal vein access site. In the 17 patients undergoing follow-up CT, the mean tilt angle of the filter was 7.14°±4.48° in the coronal plane and 8.77°±5.49° in the sagittal plane. Filter retrieval was successful in 16 of 17 patients (94.1%) in whom filter retrieval was attempted. CONCLUSION Transpopliteal IVC filter insertion is an efficient technique that results in low rates of significant filter tilt and enables a single session procedure using a single venous access site for filter insertion and percutaneous endovenous intervention. PMID:27559713
NASA Astrophysics Data System (ADS)
Rettmann, M. E.; Holmes, D. R., III; Gunawan, M. S.; Ge, X.; Karwoski, R. A.; Breen, J. F.; Packer, D. L.; Robb, R. A.
2012-03-01
Geometric analysis of the left atrium and pulmonary veins is important for studying reverse structural remodeling following cardiac ablation therapy. It has been shown that the left atrium decreases in volume and the pulmonary vein ostia decrease in diameter following ablation therapy. Most analysis techniques, however, require laborious manual tracing of image cross-sections. Pulmonary vein diameters are typically measured at the junction between the left atrium and pulmonary veins, called the pulmonary vein ostia, with manually drawn lines on volume renderings or on image cross-sections. In this work, we describe a technique for making semi-automatic measurements of the left atrium and pulmonary vein ostial diameters from high resolution CT scans and multi-phase datasets. The left atrium and pulmonary veins are segmented from a CT volume using a 3D volume approach and cut planes are interactively positioned to separate the pulmonary veins from the body of the left atrium. The cut plane is also used to compute the pulmonary vein ostial diameter. Validation experiments are presented which demonstrate the ability to repeatedly measure left atrial volume and pulmonary vein diameters from high resolution CT scans, as well as the feasibility of this approach for analyzing dynamic, multi-phase datasets. In the high resolution CT scans the left atrial volume measurements show high repeatability with approximately 4% intra-rater repeatability and 8% inter-rater repeatability. Intra- and inter-rater repeatability for pulmonary vein diameter measurements range from approximately 2 to 4 mm. For the multi-phase CT datasets, differences in left atrial volumes between a standard slice-by-slice approach and the proposed 3D volume approach are small, with percent differences on the order of 3% to 6%.
Fast traffic sign recognition with a rotation invariant binary pattern based feature.
Yin, Shouyi; Ouyang, Peng; Liu, Leibo; Guo, Yike; Wei, Shaojun
2015-01-19
Robust and fast traffic sign recognition is very important but difficult for safe driving assistance systems. This study addresses fast and robust traffic sign recognition to enhance driving safety. The proposed method includes three stages. First, a typical Hough transformation is adopted to implement coarse-grained location of the candidate regions of traffic signs. Second, a RIBP (Rotation Invariant Binary Pattern) based feature in the affine and Gaussian space is proposed to reduce the time of traffic sign detection and achieve robust traffic sign detection in terms of scale, rotation, and illumination. Third, the techniques of ANN (Artificial Neutral Network) based feature dimension reduction and classification are designed to reduce the traffic sign recognition time. Compared with the current work, the experimental results in the public datasets show that this work achieves robustness in traffic sign recognition with comparable recognition accuracy and faster processing speed, including training speed and recognition speed.
Handwritten digits recognition based on immune network
NASA Astrophysics Data System (ADS)
Li, Yangyang; Wu, Yunhui; Jiao, Lc; Wu, Jianshe
2011-11-01
With the development of society, handwritten digits recognition technique has been widely applied to production and daily life. It is a very difficult task to solve these problems in the field of pattern recognition. In this paper, a new method is presented for handwritten digit recognition. The digit samples firstly are processed and features extraction. Based on these features, a novel immune network classification algorithm is designed and implemented to the handwritten digits recognition. The proposed algorithm is developed by Jerne's immune network model for feature selection and KNN method for classification. Its characteristic is the novel network with parallel commutating and learning. The performance of the proposed method is experimented to the handwritten number datasets MNIST and compared with some other recognition algorithms-KNN, ANN and SVM algorithm. The result shows that the novel classification algorithm based on immune network gives promising performance and stable behavior for handwritten digits recognition.
Fast Traffic Sign Recognition with a Rotation Invariant Binary Pattern Based Feature
Yin, Shouyi; Ouyang, Peng; Liu, Leibo; Guo, Yike; Wei, Shaojun
2015-01-01
Robust and fast traffic sign recognition is very important but difficult for safe driving assistance systems. This study addresses fast and robust traffic sign recognition to enhance driving safety. The proposed method includes three stages. First, a typical Hough transformation is adopted to implement coarse-grained location of the candidate regions of traffic signs. Second, a RIBP (Rotation Invariant Binary Pattern) based feature in the affine and Gaussian space is proposed to reduce the time of traffic sign detection and achieve robust traffic sign detection in terms of scale, rotation, and illumination. Third, the techniques of ANN (Artificial Neutral Network) based feature dimension reduction and classification are designed to reduce the traffic sign recognition time. Compared with the current work, the experimental results in the public datasets show that this work achieves robustness in traffic sign recognition with comparable recognition accuracy and faster processing speed, including training speed and recognition speed. PMID:25608217
Infrared vehicle recognition using unsupervised feature learning based on K-feature
NASA Astrophysics Data System (ADS)
Lin, Jin; Tan, Yihua; Xia, Haijiao; Tian, Jinwen
2018-02-01
Subject to the complex battlefield environment, it is difficult to establish a complete knowledge base in practical application of vehicle recognition algorithms. The infrared vehicle recognition is always difficult and challenging, which plays an important role in remote sensing. In this paper we propose a new unsupervised feature learning method based on K-feature to recognize vehicle in infrared images. First, we use the target detection algorithm which is based on the saliency to detect the initial image. Then, the unsupervised feature learning based on K-feature, which is generated by Kmeans clustering algorithm that extracted features by learning a visual dictionary from a large number of samples without label, is calculated to suppress the false alarm and improve the accuracy. Finally, the vehicle target recognition image is finished by some post-processing. Large numbers of experiments demonstrate that the proposed method has satisfy recognition effectiveness and robustness for vehicle recognition in infrared images under complex backgrounds, and it also improve the reliability of it.
Duplex sonography for detection of deep vein thrombosis of upper extremities: a 13-year experience.
Chung, Amy S Y; Luk, W H; Lo, Adrian X N; Lo, C F
2015-04-01
To determine the prevalence and characteristics of sonographically evident upper-extremity deep vein thrombosis in symptomatic Chinese patients and identify its associated risk factors. Regional hospital, Hong Kong. Data on patients undergoing upper-extremity venous sonography examinations during a 13-year period from November 1999 to October 2012 were retrieved. Variables including age, sex, history of smoking, history of lower-extremity deep vein thrombosis, major surgery within 30 days, immobilisation within 30 days, cancer (history of malignancy), associated central venous or indwelling catheter, hypertension, diabetes mellitus, sepsis within 30 days, and stroke within 30 days were tested using binary logistic regression to understand the risk factors for upper-extremity deep vein thrombosis. The presence of upper-extremity deep vein thrombosis identified. Overall, 213 patients with upper-extremity sonography were identified. Of these patients, 29 (13.6%) had upper-extremity deep vein thrombosis. The proportion of upper-extremity deep vein thrombosis using initial ultrasound was 0.26% of all deep vein thrombosis ultrasound requests. Upper limb swelling was the most common presentation seen in a total of 206 (96.7%) patients. Smoking (37.9%), history of cancer (65.5%), and hypertension (27.6%) were the more prevalent conditions among patients in the upper-extremity deep vein thrombosis-positive group. No statistically significant predictor of upper-extremity deep vein thrombosis was noted if all variables were included. After backward stepwise logistic regression, the final model was left with only age (P=0.119), female gender (P=0.114), and history of malignancy (P=0.024) as independent variables. History of malignancy remained predictive of upper-extremity deep vein thrombosis. Upper-extremity deep vein thrombosis is uncommon among symptomatic Chinese population. The most common sign is swelling and the major risk factor for upper-extremity deep vein thrombosis identified in this study is malignancy.
Application and comparison of different implanted ports in malignant tumor patients.
Li, Yanhong; Cai, Yonghua; Gan, Xiaoqin; Ye, Xinmei; Ling, Jiayu; Kang, Liang; Ye, Junwen; Zhang, Xingwei; Zhang, Jianwei; Cai, Yue; Hu, Huabin; Huang, Meijin; Deng, Yanhong
2016-09-23
The current study aims to compare the application and convenience of the upper arm port with the other two methods of implanted ports in the jugular vein and the subclavian vein in patients with gastrointestinal cancers. Currently, the standard of practice is placement of central venous access via an internal jugular vein approach. Perioperative time, postoperative complications, and postoperative comfort level in patients receiving an implanted venous port in the upper arm were retrospectively compared to those in the jugular vein and the subclavian vein from April 2013 to November 2014. Three hundred thirty-four patients are recruited for this analysis, consisting of 107 in the upper arm vein group, 70 in the jugular vein group, and 167 in the subclavian vein group. The occurrence of catheter misplacement in the upper arm vein is higher than that in the other two groups (13.1 vs. 2.9 vs. 5.4 %, respectively, P = 0.02), while the other complications in the perioperative period were not significantly different. The occurrence of transfusion obstacle of the upper arm vein group is significantly lower than that of the jugular and subclavian groups (0.9 vs. 7.1 vs. 7.2 %, P = 0.01). The occurrence of thrombus is also lower than that of other two groups (0.9 vs. 4.3 vs. 3.6 %, P = 0.03). Regarding the postoperative comfort, the influences of appearance (0 vs. 7.1 vs. 2.9 %, P = 0.006) and sleep (0.9 vs. 4.2 vs. 10.7 %, P = 0.003) are significantly better than those of the jugular and subclavian vein groups. Compared to the jugular and the subclavian vein groups, the implanted venous port in the upper arm vein has fewer complications and more convenience and comfort, and might be a superior novel choice for patients requiring long-term chemotherapy or parenteral nutrition.
Dimensional analysis of human saphenous vein grafts: Implications for external mesh support.
Human, Paul; Franz, Thomas; Scherman, Jacques; Moodley, Lovendran; Zilla, Peter
2009-05-01
Constrictive external mesh support of vein grafts was shown to mitigate intimal hyperplasia in animal experiments. To determine the degree of constriction required for the elimination of dimensional irregularities in clinically used vein grafts, a detailed anatomic study of human saphenous veins was conducted. In 200 consecutive patients having coronary artery bypass grafting, harvested saphenous veins (length 34.4 +/- 10.8 cm) were analyzed regarding diameter irregularities, side branch distribution, and microstructure. The mean outer diameter of surgically distended saphenous veins was 4.2 +/- 0.6 mm (men, 4.3 +/- 0.6 mm vs women, 3.9 +/- 0.5 mm; P < .0001). Although the outer diameter significantly decreased over the initial 18 cm (-7.6%; P < .0001), the overall increase between malleolus and thigh was not significant (+11.2%). Smaller-diameter veins (<3.5 mm) had more pronounced diameter fluctuations than larger veins (31.8% +/- 11.0% vs 21.2% +/- 8.8%; P < .0001), with more than 71% of all veins showing caliber changes of more than 20%. There was 1 side branch every 5.4 +/- 4.3 cm, with a significantly higher incidence between 20 and 32 cm from the malleolus (P < .0001 to distal, P < .0004 to proximal). Generally, women had more side branches than men (0.30 +/- 0.15 cm(-1) vs 0.25 +/- 0.12 cm(-1); P = .0190). Thick-walled veins (565.7 +/- 138.4 mum) had a significantly higher number of large side branches (P < .0001), and thin-walled veins (398.7 +/- 123.2 mum) had significantly more small side branches (P < .0001). Pronounced intimal thickening ("cushions") was found in 28% of vessels (119.8 +/- 28.0 mum vs 40.1 +/- 18.2 mum; P < .0001). Although the preferential location of side branches may be addressed by the deliberate discarding of infragenicular vein segments, a diameter constriction of 27% on average would eliminate diameter irregularities in 98% of vein grafts.
Spencer, Julianne H; Goff, Ryan P; Iaizzo, Paul A
2015-07-01
The objective of this study was to quantitatively characterize anatomy of the human phrenic nerve in relation to the coronary venous system, to reduce undesired phrenic nerve stimulation during left-sided lead implantations. We obtained CT scans while injecting contrast into coronary veins of 15 perfusion-fixed human heart-lung blocs. A radiopaque wire was glued to the phrenic nerve under CT, then we created three-dimensional models of anatomy and measured anatomical parameters. The left phrenic nerve typically coursed over the basal region of the anterior interventricular vein, mid region of left marginal veins, and apical region of inferior and middle cardiac veins. There was large variation associated with the average angle between nerve and veins. Average angle across all coronary sinus tributaries was fairly consistent (101.3°-111.1°). The phrenic nerve coursed closest to the middle cardiac vein and left marginal veins. The phrenic nerve overlapped a left marginal vein in >50% of specimens. © 2015 Wiley Periodicals, Inc.
Takeuchi, Hajime; Takeda, Yoko; Takahashi, Miyo; Hayashi, Shogo; Fukuzawa, Yoshitaka; Nakano, Takashi
2014-09-01
To observe a case of congenital extrahepatic portosystemic shunt and discuss it from the embryological and clinical viewpoints. An 85-year-old female cadaver was employed for a dissection course at Aichi Medical University in 2009. There was no evidence of liver cirrhosis macroscopically or microscopically. A portosystemic shunt was observed that involved communication between the inferior mesenteric vein, inferior vena cava (IVC), and left ovarian vein by a single Y-shaped shunt vessel. To the best of our knowledge, this is the first reported case of the above-mentioned three veins being connected by a single Y-shaped shunt vessel. Considering the other venous diameters, the shunt appeared to flow into the splenic vein and IVC. It cannot be denied that this shunt may have led to hepatic encephalopathy, although the shunt effect may have been minimal. Embryological development of IVC appears to occur close to the plexus of anastomosing vitelline veins, forming the portal vein.
Venous catheterization with ultrasound navigation
NASA Astrophysics Data System (ADS)
Kasatkin, A. A.; Urakov, A. L.; Nigmatullina, A. R.
2015-11-01
By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization. We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient's exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.
Association of deep venous thrombosis with calf vein diameter in acute hemorrhagic stroke.
Ogata, Toshiyasu; Yasaka, Masahiro; Wakugawa, Yoshiyuki; Kitazono, Takanari; Okada, Yasushi
2013-10-01
We investigated the association between the development of deep venous thrombosis (DVT) and calf vein diameter in patients with acute hemorrhagic stroke. We measured the maximum diameter of paralytic side posttibial veins (PTVs) and peroneal veins (PVs) in 49 patients with intracerebral hemorrhage on admission and at 2 weeks after stroke onset by ultrasonography. We also examined for the presence or absence of DVT, and then analyzed the association of DVT with the maximum vein diameter. At 2 weeks after stroke, DVTs were detected in PTVs in 7 patients and in PVs in 6 patients. The maximum calf vein diameters at 2 weeks were significantly greater in patients with DVT compared with those without DVT (PTV, P = .033; PV, P = .015). Although calf vein diameter at admission did not influence the future incidence of DVT in patients with intracerebral hemorrhage, the presence of DVT was associated with calf vein dilatation. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Novel Percutaneous Radiofrequency Ablation of Portal Vein Tumor Thrombus: Safety and Feasibility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mizandari, Malkhaz; Ao, Guokun; Zhang Yaojun
2013-02-15
We report our experience of the safety of partial recanalization of the portal vein using a novel endovascular radiofrequency (RF) catheter for portal vein tumor thrombosis. Six patients with liver cancer and tumor thrombus in the portal vein underwent percutaneous intravascular radiofrequency ablation (RFA) using an endovascular bipolar RF device. A 0.035-inch guidewire was introduced into a tributary of the portal vein and through which a 5G guide catheter was introduced into the main portal vein. After manipulation of the guide catheter over the thrombus under digital subtraction angiography, the endovascular RF device was inserted and activated around the thrombus.more » There were no observed technique specific complications, such as hemorrhage, vessel perforation, or infection. Post-RFA portography showed partial recanalization of portal vein. RFA of portal vein tumor thrombus in patients with hepatocellular carcinoma is technically feasible and warrants further investigation to assess efficacy compared with current recanalization techniques.« less
Venous catheterization with ultrasound navigation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasatkin, A. A., E-mail: ant-kasatkin@yandex.ru; Nigmatullina, A. R.; Urakov, A. L., E-mail: ant-kasatkin@yandex.ru
By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization.more » We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient’s exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.« less
Takahashi, Michiro; Saiura, Akio; Takahashi, Yu
2017-11-01
Patients with tumors invading major veins may require combined resection and reconstruction. However, venous reconstruction often demands complex hepatobiliary and vascular surgical procedures. In this study, we report a simple patch repair technique for venous reconstruction using the repermeabilized umbilical vein of the round ligament. We reviewed the outcomes of eleven patients who underwent venous wedge resection and patch repair using the repermeabilized umbilical vein of the round ligament at our institution. Procurement of the round ligament and method of making a patch is simple. The duration of anastomosis was approximately 15 min. Eight patients (73%) underwent hepatic resection followed by hepatic vein reconstruction; two (18%) pancreaticoduodenectomy followed by inferior vena cava (IVC) reconstruction; one (9%) hepatic resection followed by IVC reconstruction. Although one reconstructed vein became narrowed, the other ten veins were patent after surgery. Patch repair using the repermeabilized umbilical vein of the round ligament is a simple and useful technique.
Renal Ammonia Metabolism and Transport
Weiner, I. David; Verlander, Jill W.
2015-01-01
Renal ammonia metabolism and transport mediates a central role in acid-base homeostasis. In contrast to most renal solutes, the majority of renal ammonia excretion derives from intrarenal production, not from glomerular filtration. Renal ammoniagenesis predominantly results from glutamine metabolism, which produces 2 NH4+ and 2 HCO3− for each glutamine metabolized. The proximal tubule is the primary site for ammoniagenesis, but there is evidence for ammoniagenesis by most renal epithelial cells. Ammonia produced in the kidney is either excreted into the urine or returned to the systemic circulation through the renal veins. Ammonia excreted in the urine promotes acid excretion; ammonia returned to the systemic circulation is metabolized in the liver in a HCO3−-consuming process, resulting in no net benefit to acid-base homeostasis. Highly regulated ammonia transport by renal epithelial cells determines the proportion of ammonia excreted in the urine versus returned to the systemic circulation. The traditional paradigm of ammonia transport involving passive NH3 diffusion, protonation in the lumen and NH4+ trapping due to an inability to cross plasma membranes is being replaced by the recognition of limited plasma membrane NH3 permeability in combination with the presence of specific NH3-transporting and NH4+-transporting proteins in specific renal epithelial cells. Ammonia production and transport are regulated by a variety of factors, including extracellular pH and K+, and by several hormones, such as mineralocorticoids, glucocorticoids and angiotensin II. This coordinated process of regulated ammonia production and transport is critical for the effective maintenance of acid-base homeostasis. PMID:23720285
Sub-pattern based multi-manifold discriminant analysis for face recognition
NASA Astrophysics Data System (ADS)
Dai, Jiangyan; Guo, Changlu; Zhou, Wei; Shi, Yanjiao; Cong, Lin; Yi, Yugen
2018-04-01
In this paper, we present a Sub-pattern based Multi-manifold Discriminant Analysis (SpMMDA) algorithm for face recognition. Unlike existing Multi-manifold Discriminant Analysis (MMDA) approach which is based on holistic information of face image for recognition, SpMMDA operates on sub-images partitioned from the original face image and then extracts the discriminative local feature from the sub-images separately. Moreover, the structure information of different sub-images from the same face image is considered in the proposed method with the aim of further improve the recognition performance. Extensive experiments on three standard face databases (Extended YaleB, CMU PIE and AR) demonstrate that the proposed method is effective and outperforms some other sub-pattern based face recognition methods.
Blood perfusion construction for infrared face recognition based on bio-heat transfer.
Xie, Zhihua; Liu, Guodong
2014-01-01
To improve the performance of infrared face recognition for time-lapse data, a new construction of blood perfusion is proposed based on bio-heat transfer. Firstly, by quantifying the blood perfusion based on Pennes equation, the thermal information is converted into blood perfusion rate, which is stable facial biological feature of face image. Then, the separability discriminant criterion in Discrete Cosine Transform (DCT) domain is applied to extract the discriminative features of blood perfusion information. Experimental results demonstrate that the features of blood perfusion are more concentrative and discriminative for recognition than those of thermal information. The infrared face recognition based on the proposed blood perfusion is robust and can achieve better recognition performance compared with other state-of-the-art approaches.
Facial expression recognition based on improved local ternary pattern and stacked auto-encoder
NASA Astrophysics Data System (ADS)
Wu, Yao; Qiu, Weigen
2017-08-01
In order to enhance the robustness of facial expression recognition, we propose a method of facial expression recognition based on improved Local Ternary Pattern (LTP) combined with Stacked Auto-Encoder (SAE). This method uses the improved LTP extraction feature, and then uses the improved depth belief network as the detector and classifier to extract the LTP feature. The combination of LTP and improved deep belief network is realized in facial expression recognition. The recognition rate on CK+ databases has improved significantly.
NASA Astrophysics Data System (ADS)
Runyon, Simone E.; Steele-MacInnis, Matthew; Seedorff, Eric; Lecumberri-Sanchez, Pilar; Mazdab, Frank K.
2017-04-01
Veins and pervasive wall-rock alteration composed of coarse muscovite±quartz±pyrite are documented for the first time in a porphyritic granite at Luhr Hill in the Yerington District, Nevada. Coarse muscovite at Luhr Hill occurs at paleodepths of 6-7 km in the roots of a porphyry copper system and crops out on the scale of tens to hundreds of meters, surrounded by rock that is unaltered or variably altered to sodic-calcic assemblages. Coarse muscovite veins exhibit a consistent orientation, subvertical and N-S striking, which structurally restores to subhorizontal at the time of formation. Along strike, coarse muscovite veins swell from distal, millimeter-thick muscovite-only veinlets to proximal, centimeter-thick quartz-sulfide-bearing muscovite veins. Crosscutting relationships between coarse muscovite veins, pegmatite dikes, and sodic-calcic veins indicate that muscovite veins are late-stage magmatic-hydrothermal features predating final solidification of the Luhr Hill porphyritic granite. Fluid inclusions in the muscovite-quartz veins are high-density aqueous inclusions of 3-9 wt% NaCl eq. and <1 mol% CO2 that homogenize between 150 and 200 °C, similar to fluid inclusions from greisen veins in Sn-W-Mo vein systems. Our results indicate that muscovite-forming fluids at Luhr Hill were mildly acidic, of low to moderate salinity and sulfur content and low CO2 content, and that muscovite in deep veins and alteration differs in texture, composition, and process of formation from sericite at shallower levels of the hydrothermal system. Although the definition of greisen is controversial, we suggest that coarse muscovite alteration is more similar to alteration in greisen-type Sn-W-Mo districts worldwide than to sericitic alteration at higher levels of porphyry copper systems. The fluids that form coarse muscovite veins and alteration in the roots of porphyry copper systems are distinct from fluids that formed copper ore or widespread, shallower, acidic alteration. We propose that this style of veins and alteration at Luhr Hill represents degassing of moderate volumes of overpressured hydrothermal fluid during late crystallization of deep levels of the Yerington batholith.
The umbilical and paraumbilical veins of man.
Martin, B F; Tudor, R G
1980-01-01
During its transit through the umbilicus structural changes occur in the thick wall of the extra-abdominal segment of the umbilical vein whereby the components of the intra-abdominal segment acquire an essentially longitudinal direction and become arranged in fibro-elastic and fibro-muscular zones. The vein lumen becomes largely obliterated by asymmetrical proliferation of loose subendothelial conective tissue. The latter forms a new inner zone within which a small segment of the lumen persists in an eccentric position. This residual lumen transmits blood to the portal system from paraumbilical and systemic sources, and is retained in the upper part of the vein, even in old age. A similar process of lumen closure is observed in the ductus venosus. In early childhood the lower third of the vein undergoes breakdown, with fatty infiltration, resulting in its complete division into vascular fibro-elastic strands, and in old age some breakdown occurs in the outermost part of the wall of the upper two thirds. The paraumbilical veins are thick-walled and of similar structure to the umbilical vein. Together they constitute an accessory portal system which is confined between the layers of the falciform ligament and is in communication with the veins of the ventral abdominal wall. The constituents form an ascending series, namely, Burow's veins, the umbilical vein, and Sappey's inferior and superior veins. The main channel of Sappey's inferior veins may be the remnant of the right umbilical vein since it communicates with the right rectus sheath and often communicates directly with the portal system within the right lobe of the liver. The results are of significance in relation to clinical usage of the umbilical vein. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 Fig. 17 Fig. 18 Fig. 19 Fig. 20 Fig. 21 Fig. 22 Fig. 23 Fig. 24 Fig. 25 Fig. 26 Fig. 27 Fig. 28 Fig. 29 PMID:7400038
NASA Astrophysics Data System (ADS)
Walton, Erin L.
2013-04-01
Lithology A of Martian meteorite Elephant Moraine (EET) A79001 contains fragments entrained within a 100 μm-thick shear-induced shock vein. These fragments, the shock vein matrix and walls of olivine along the vein, as well as shock deformation and transformation in rock-forming minerals in the bulk rock, were investigated using scanning electron microscopy, the electron microprobe and Raman spectroscopy. The presence of ringwoodite, the spinel-structured high-pressure (Mg,Fe)2SiO4 polymorph, has been confirmed in EETA79001 for the first time. Ringwoodite occurs within and around the shock vein, exhibiting granular and lamellar textures. In both textures ringwoodite consists of ˜500 nm size distinct grains. Ringwoodite lamellae are 115 nm to 1.3 μm wide. Planar fractures in olivine provided sites for heterogeneous nucleation of ringwoodite. Analyses performed on the largest grains (⩾1 μm) show that ringwoodite is consistently higher in iron (Fa27.4-32.4) relative to surrounding olivine (Fa25.1-267.7), implying that there was Fe-Mg exchange during their transformation, and therefore their growth was diffusion-controlled. In the shock environment, diffusion takes place dynamically, i.e., with concurrent deformation and grain size reduction. This results in enhanced diffusion rates (⩾10-8 m2/s) over nm - μm distances. Shock deformation in host rock minerals including strong mosaicism, pervasive fracturing, polysynthetic twinning (pyroxene only), extensive shock melting, local transformation of olivine to ringwoodite, and complete transformation of plagioclase to maskelynite in the bulk rock, indicate that EETA79001 was strongly shocked. The short shock duration (0.01 s) combined with a complex thermal history, resulted in crystallization of the 100 μm thick shock vein in EETA79001 during the pressure release, and partial back-transformation of ringwoodite to olivine. Based on the pressure stabilities of clinopyroxene + ringwoodite, crystallization at the shock vein margin began at ˜18 GPa. Olivine and clinopyroxene crystallized at <14 GPa closer to the shock vein center. These represent a minimum limit to the shock pressure loading experienced by EETA79001.
Gaye, Magaye; Ndiaye, Assane; Dieng, Papa Adama; Ndiaye, Aynina; Ba, Papa Salmane; Diatta, Souleymane; Ciss, Amadou Gabriel; Ndoye, Jean Marc Ndiaga; Diop, Mamadou; Ndiaye, Abdoulaye; Ndiaye, Mouhamadou; Dia, Abdarahmane
2016-01-01
Introduction L’artère pudendale externe est une branche collatérale de l’artère fémorale commune qui est destinée à la vascularisation du pénis ou du clitoris. Ses rapports avec la crosse de la grande veine saphène et de ses afférences, dans le trigone fémoral, sont très étroits. Cette situation fait qu’elle est souvent lésée lors de la crossectomie et de l’éveinage de la grande veine saphène. Ces lésions peuvent être à l’origine d’une dysfonction sexuelle. Méthodes Il s’agit d’une dissection de 22 régions inguinales chez 13 hommes et 9 femmes qui ont bénéficié d’un abord chirurgical du trigone fémoral. La distribution et les rapports de l’artère pudendale externe par rapport à la crosse de la grande veine saphène sont étudiés. Résultats L’artère pudendale externe unique est la plus fréquente. Toutes les artères pudendales externes ont pour origine l’artère fémorale commune. Le rapport le plus fréquent est le sous croisement de la crosse de la grande veine saphène par une artère pudendale externe unique. Par ailleurs, on a un précroisement, un croisement alterné et des rapports avec la veine fémorale commune et des afférences de la crosse de la grande veine saphène. Certaines techniques chirurgicales exposent plus ou moins à une lésion de l’artère pudendale externe. Conclusion Ce travail confirme les données antérieures mais montre encore quelques particularités sur les rapports entre la crosse de la grande veine saphène et l’artère pudendale externe. PMID:27795794
Vein Graft Preservation Solutions, Patency, and Outcomes After Coronary Artery Bypass Graft Surgery
Harskamp, Ralf E.; Alexander, John H.; Schulte, Phillip J.; Brophy, Colleen M.; Mack, Michael J.; Peterson, Eric D.; Williams, Judson B.; Gibson, C. Michael; Califf, Robert M.; Kouchoukos, Nicholas T.; Harrington, Robert A.; Ferguson, T. Bruce; Lopes, Renato D.
2015-01-01
IMPORTANCE In vitro and animal model data suggest that intraoperative preservation solutions may influence endothelial function and vein graft failure (VGF) after coronary artery bypass graft (CABG) surgery. Clinical studies to validate these findings are lacking. OBJECTIVE To evaluate the effect of vein graft preservation solutions on VGF and clinical outcomes in patients undergoing CABG surgery. DESIGN, SETTING, AND PARTICIPANTS Data from the Project of Ex-Vivo Vein Graft Engineering via Transfection IV (PREVENT IV) study, a phase 3, multicenter, randomized, double-blind, placebo-controlled trial that enrolled 3014 patients at 107 US sites from August 1, 2002, through October 22, 2003, were used. Eligibility criteria for the trial included CABG surgery for coronary artery disease with at least 2 planned vein grafts. INTERVENTIONS Preservation of vein grafts in saline, blood, or buffered saline solutions. MAIN OUTCOMES AND MEASURES One-year angiographic VGF and 5-year rates of death, myocardial infarction, and subsequent revascularization. RESULTS Most patients had grafts preserved in saline (1339 [44.4%]), followed by blood (971 [32.2%]) and buffered saline (507 [16.8%]). Baseline characteristics were similar among groups. One-year VGF rates were much lower in the buffered saline group than in the saline group (patient-level odds ratio [OR], 0.59 [95% CI, 0.45-0.78; P < .001]; graft-level OR, 0.63 [95% CI, 0.49-0.79; P < .001]) or the blood group (patient-level OR, 0.62 [95% CI, 0.46-0.83; P = .001]; graft-level OR, 0.63 [95% CI, 0.48-0.81; P < .001]). Use of buffered saline solution also tended to be associated with a lower 5-year risk for death, myocardial infarction, or subsequent revascularization compared with saline (hazard ratio, 0.81 [95% CI, 0.64-1.02; P = .08]) and blood (0.81 [0.63-1.03; P = .09]) solutions. CONCLUSIONS AND RELEVANCE Patients undergoing CABG whose vein grafts were preserved in a buffered saline solution had lower VGF rates and trends toward better long-term clinical outcomes compared with patients whose grafts were preserved in saline- or blood-based solutions. PMID:25073921
Geology and mineral deposits of the Jabal ash Shumta quadrangle, Kingdom of Saudi Arabia
Hummel, C.L.; Ankary, Abdullah O.
1972-01-01
Rocks, structures, and mineral deposits which are the result of both the older Halaban petro-tectonic cycle and the younker Najd Wrench Fault deformation are present in the Ash Shumta area. Northward-trending belts of granitic rocks and folded, layered metavolcanic and metasedimentary rocks of the Halaban Formation which they intrude represent the effects of the Halaban cycle. These older rocks are everywhere transected and deformed by northwestward- and northeastward-striking fractures and strike-slip faults and by eastward-striking fractures and fracture-controlled silicic dikes which belong to the Najd Wrench Fault deformation. Several kinds of epigenetic mineral deposits of hydrothermal origin are present throughout the Ash Shumta area. All occur in or ape closely associated with structures of the Najd Wrench Fault deformation. The mineralization which produced the deposits is thought to have taken place during the period of deformation which produced the Najd Wrench Fault structures. The hydrothermal deposits include many metalliferous quartz veins most of which occur in three mineralized areas: two major areas at Jabal Ash Shumta and Jabal El Khom in the northern half of the quadrangle and a minor area along Wadj al Boharah in the southeastern part of the quadrangle. The metalliferous lodes possess the only economic potential in the area of the Jabal Ash Shumta quadrangle. These lodes consist mainly of gold and base metal-bearing quartz veins, some of which were mined for gold in ancient times. The mineralized area at Jabal Ash Shumta has the best of these veins. Higher temperature veins with wolframite as a major constituent and beryl as a minor one occur in a granite cupola in the eastern part of the El Khom area. These veins have altered, gneissen-like wall rocks. Although the grade of the veins is low at the surface, the made could increase at depth. The tungsten-bearing veins and El Khom area possess the greatest economic promise in the Jabal Ash Shumta quadrangle. They deserve detailed surface investigation followed if needed by exploration at depth.
Research of flaw image collecting and processing technology based on multi-baseline stereo imaging
NASA Astrophysics Data System (ADS)
Yao, Yong; Zhao, Jiguang; Pang, Xiaoyan
2008-03-01
Aiming at the practical situations such as accurate optimal design, complex algorithms and precise technical demands of gun bore flaw image collecting, the design frame of a 3-D image collecting and processing system based on multi-baseline stereo imaging was presented in this paper. This system mainly including computer, electrical control box, stepping motor and CCD camera and it can realize function of image collection, stereo matching, 3-D information reconstruction and after-treatments etc. Proved by theoretical analysis and experiment results, images collected by this system were precise and it can slake efficiently the uncertainty problem produced by universally veins or repeated veins. In the same time, this system has faster measure speed and upper measure precision.
The economics of vein disease.
Sales, Clifford M; Podnos, Joan; Levison, Jonathan
2007-09-01
The management of cosmetic vein problems requires a very different approach than that for the majority of most other vascular disorders that occur in a vascular surgery practice. This article focuses on the business aspects of a cosmetic vein practice, with particular attention to the uniqueness of these issues. Managing patient expectations is critical to the success of a cosmetic vein practice. Maneuvering within the insurance can be difficult and frustrating for both the patient and the practice. Practices should use cost accounting principles to evaluate the success of their vein work. Vein surgery--especially if performed within the office--can undergo an accurate break-even analysis to determine its profitability.
Congenital absence of the portal vein in a middle-aged man.
Barchetti, Flavio; Pellegrino, Luigi; Al-Ansari, Najwa; De Marco, Valentina; Scarpato, Paolo; Ialongo, Pasquale
2011-05-01
Congenital absence of the portal vein with systemic diversion of mesenteric blood is extremely rare. We report a case of a congenital absence of the portal vein, accidentally discovered in a 59-year-old man, completely asymptomatic and not associated with other malformations or biochemical disorders. Ultrasonography imaging showed the absence of the portal vein and the distal tract of superior mesenteric and splenic veins draining together into a dilated left renal vein. Computed tomography and magnetic resonance confirmed the presence of a congenital portosystemic venous shunt and also revealed two hepatic arteries: one arising from the celiac trunk and the other from the superior mesenteric artery.
Iwai, Takehisa; Sato; Kume, Hiroko; Inoue, Yoshinori; Umeda, Makoto; Kagayama, Tomoko; Hirokawa, Masayuki
2012-01-01
Three of four (75%) vein biopsy samples from four patients (all male, mean onset: age 33.0, mean biopsy: age 59.7) of chronic phase phlebitis migrans showed positive periodontal bacteria DNA under the PCR (polymerase chain reaction) method. Of the 24 cases of Buerger disease (22 males, 2 females, mean onset: age 31.9, mean examination: age 62.6) that were investigated in our vascular laboratory, 65% of the patients suffered from moderate to severe varicose veins. Eight cases had a history of phlebitis migrans and three had an active ulcer or uncontrollable erosion in the foot. The rate of incidence was significantly higher than that of the well-matched control group. Other findings included one instance of deep vein thrombosis, and one instance of deep vein reflux. We could suggest that some intractable ulcer or erosion cases of Buerger disease may be complicated by superficial vein incompetence or other deep vein insufficiency. We also we need to check Buerger disease patients with duplex for vein reflux and other insufficiencies. Treatment of the varicose veins (including elastic stockings) was effective for all of the patients. (English Translation of Jpn J Phlebology 2011; 22: 25–31.) PMID:23555485
Sato, Katsutoshi; Orihashi, Kazumasa; Takahashi, Shinya; Takasaki, Taiichi; Kurosaki, Tatsuya; Imai, Katsuhiko; Ishifuro, Minoru; Sueda, Taijiro
2011-01-01
Objective: We preoperatively assessed varicose veins by means of computed tomography (CT) with contrast injection in the veins of the lower extremity (CT venography). This paper reports the procedures, results and implications of CT venography from the surgical aspect. Methods: A total of 48 legs in 39 patients were examined. Contrast medium was diluted ten-fold and injected into the lower extremity veins, often using a dual route of injection. The images were reconstructed with the volume-rendering method. Results: CT venography clearly visualized the veins with a small amount of contrast medium and facilitated the identification of anatomy that was not suitable for passing the stripper. In addition, CT venography helped identify unusual types of varicose veins or uncommon sites of inflow of small saphenous veins. Such information was helpful for avoiding unexpected vascular injury or for minimizing skin incision. Dual-route injection was beneficial to minimize the blind zones. Doppler ultrasound could be more focused on hemodynamic assessment and determination of incision sites. Conclusions: CT Venography is feasible in all cases of varicose veins. When performed in conjunction with ultrasonography, it appears to facilitate the safe and efficient treatment of various types of varicose veins. PMID:23555458
Geometric Analysis of Vein Fracture Networks From the Awibengkok Core, Indonesia
NASA Astrophysics Data System (ADS)
Khatwa, A.; Bruhn, R. L.; Brown, S. R.
2003-12-01
Fracture network systems within rocks are important features for the transportation and remediation of hazardous waste, oil and gas production, geothermal energy extraction and the formation of vein fillings and ore deposits. A variety of methods, including computational and laboratory modeling have been employed to further understand the dynamic nature of fractures and fracture systems (e.g. Ebel and Brown, this session). To substantiate these studies, it is also necessary to analyze the characteristics and morphology of naturally occurring vein systems. The Awibengkok core from a geothermal system in West Java, Indonesia provided an excellent opportunity to study geometric and petrologic characteristics of vein systems in volcanic rock. Vein minerals included chlorite, calcite, quartz, zeolites and sulphides. To obtain geometric data on the veins, we employed a neural net image processing technique to analyze high-resolution digital photography of the veins. We trained a neural net processor to map the extent of the vein using RGB pixel training classes. The resulting classification image was then converted to a binary image file and processed through a MatLab program that we designed to calculate vein geometric statistics, including aperture and roughness. We also performed detailed petrographic and microscopic geometric analysis on the veins to determine the history of mineralization and fracturing. We found that multi-phase mineralization due to chemical dissolution and re-precipitation as well as mechanical fracturing was a common feature in many of the veins and that it had a significant role for interpreting vein tortuosity and history of permeability. We used our micro- and macro-scale observations to construct four hypothetical permeability models that compliment the numerical and laboratory modeled data reported by Ebel and Brown. In each model, permeability changes, and in most cases fluctuates, differently over time as the tortuosity and aperture of veins are affected by the precipitation, dissolution, and re-precipitation of minerals, and also by mechanical fracturing. In all of our cases we interpret a first-phase mineral dissolution stage where permeability gradually declines as the vein is blocked by inward growing minerals. Hereafter, permeability may briefly increase with the onset of internal fracturing within the vein or by a phase of mineral dissolution opening up new pathways for fluid flow. Eventually we infer that permeability will decline again as second stage minerals are deposited in the fluid flow pathways.
What Are Varicose Veins? (For Kids)
... full of oxygen, which makes the blood bright red. But the blood coming back from your body in the veins is darker because your body parts have used up the oxygen in the blood. That's why veins look purple or blue. What Causes Varicose Veins? It's a lot of ...
Weighted Feature Gaussian Kernel SVM for Emotion Recognition
Jia, Qingxuan
2016-01-01
Emotion recognition with weighted feature based on facial expression is a challenging research topic and has attracted great attention in the past few years. This paper presents a novel method, utilizing subregion recognition rate to weight kernel function. First, we divide the facial expression image into some uniform subregions and calculate corresponding recognition rate and weight. Then, we get a weighted feature Gaussian kernel function and construct a classifier based on Support Vector Machine (SVM). At last, the experimental results suggest that the approach based on weighted feature Gaussian kernel function has good performance on the correct rate in emotion recognition. The experiments on the extended Cohn-Kanade (CK+) dataset show that our method has achieved encouraging recognition results compared to the state-of-the-art methods. PMID:27807443
HWDA: A coherence recognition and resolution algorithm for hybrid web data aggregation
NASA Astrophysics Data System (ADS)
Guo, Shuhang; Wang, Jian; Wang, Tong
2017-09-01
Aiming at the object confliction recognition and resolution problem for hybrid distributed data stream aggregation, a distributed data stream object coherence solution technology is proposed. Firstly, the framework was defined for the object coherence conflict recognition and resolution, named HWDA. Secondly, an object coherence recognition technology was proposed based on formal language description logic and hierarchical dependency relationship between logic rules. Thirdly, a conflict traversal recognition algorithm was proposed based on the defined dependency graph. Next, the conflict resolution technology was prompted based on resolution pattern matching including the definition of the three types of conflict, conflict resolution matching pattern and arbitration resolution method. At last, the experiment use two kinds of web test data sets to validate the effect of application utilizing the conflict recognition and resolution technology of HWDA.
Gibson, Kathleen; Ferris, Brian
2017-04-01
Purpose Cyanoacrylate closure of the great saphenous vein with the VenaSeal™ Closure System is a relatively new modality. Studies have been limited to moderate-sized great saphenous veins and some have mandated postoperative compression stockings. We report the results of a prospective study of cyanoacrylate closure for the treatment of great saphenous vein, small saphenous veins, and/or accessory saphenous veins up to 20 mm in diameter. Methods Fifty subjects with symptomatic great saphenous vein, small saphenous veins, and/or accessory saphenous veins incompetence were each treated at a single session. Compression stockings were not used post-procedure. Subjects returned to clinic at week 1 and again at one month. Post-procedure evaluations were performed at seven days and one month and included numerical pain rating score, revised venous clinical severity score, the Aberdeen Varicose Vein Questionnaire score, and time to return to work and normal activities. Duplex ultrasound was performed at each visit. Findings Procedural pain was mild (numerical pain rating scale 2.2 ± 1.8). All treated veins (48 great saphenous vein, 14 accessory saphenous veins, and 8 small saphenous veins) had complete closure by duplex ultrasound at seven days and one month. Mean time to return to work and normal activities was 0.2 ± 1.1 and 2.4 ± 4.1 days, respectively. The revised venous clinical severity score was improved to 1.8 ± 1.4 ( p < .001) and Aberdeen Varicose Vein Questionnaire score to 8.9 ± 6.6 ( p < .001) at one month. Phlebitis in the treatment area or side branches occurred in 10 subjects (20%) and completely resolved in all but one subject (2%) by one month; 98% of subjects were "completely" or "somewhat" satisfied, and 2% "unsatisfied" with the procedure at one month, despite the protocol disallowance of concomitant side branch treatment. Conclusions Cyanoacrylate closure is safe and effective for the treatment of one or more incompetent saphenous or accessory saphenous veins. Closure rates were high even in the absence of the use of compression stockings or side branch treatment. Time back to work or normal activities was short and improvements in venous severity scores and QOL were significant, comparing favorably with alternative treatment methods.
The Relative Success of Recognition-Based Inference in Multichoice Decisions
ERIC Educational Resources Information Center
McCloy, Rachel; Beaman, C. Philip; Smith, Philip T.
2008-01-01
The utility of an "ecologically rational" recognition-based decision rule in multichoice decision problems is analyzed, varying the type of judgment required (greater or lesser). The maximum size and range of a counterintuitive advantage associated with recognition-based judgment (the "less-is-more effect") is identified for a range of cue…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guevara, Carlos J., E-mail: guevarac@mir.wustl.edu; El-Hilal, Alexander H., E-mail: elhilala@mir.wustl.edu; Darcy, Michael D., E-mail: darcym@mir.wustl.edu
This is a case report of an adolescent male who underwent surgical ligation for a left-sided varicocele that recurred 2 years later. Standard retrograde embolization via the left renal vein was not possible, because there was no connection from the renal vein to the gonadal vein following surgical ligation. The patient was treated via antegrade access of the spermatic vein at the inguinal level with subsequent coil embolization.
Whiteley, M S; Dos Santos, S J; Harrison, C C; Holdstock, J M; Lopez, A J
2015-12-01
To assess the suitability of transvaginal duplex ultrasonography to identify pathological reflux in the ovarian and internal iliac veins in women. A retrospective study of patients treated in 2011 and 2012 was performed in a specialised vein clinic. Diagnostic transvaginal duplex ultrasonography in women presenting with symptoms or signs of pelvic vein reflux were compared with the outcomes of treatment from pelvic vein embolisation. A repeat transvaginal duplex ultrasonography was performed 6 weeks later by a blinded observer and any residual reflux was identified. Results from 100 sequential patients were analysed. Mean age 44.2 years (32-69) with mode average parity of 3 (0-5 deliveries). Pre-treatment, 289/400 veins were refluxing (ovarian - 29 right, 81 left; internal iliac - 93 right, 86 left). Coil embolisation was successful in 86/100 patients and failed partially in 14/100 - 5 due to failure to cannulate the target vein. One false-positive diagnosis was made. Currently there is no accepted gold standard for pelvic vein incompetence. Comparing transvaginal duplex ultrasonography with the outcome from selectively treating the veins identified as having pathological reflux with coil embolisation, there were no false-negative diagnoses and only one false-positive. This study suggests that transvaginal duplex ultrasonography could be the gold standard in assessing pelvic vein reflux. © The Author(s) 2014.