40 CFR 264.1087 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Closed-vent systems and control devices. 264.1087 Section 264.1087 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....1087 Standards: Closed-vent systems and control devices. (a) This section applies to each closed-vent...
40 CFR 61.349 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Emission Standard for Benzene Waste Operations § 61.349 Standards: Closed-vent systems and control devices... efficiency of 95 weight percent or greater, or shall recover or control the benzene emissions vented to it..., or shall recover or control the benzene emissions vented to it with an efficiency of 98 weight...
40 CFR 61.349 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Emission Standard for Benzene Waste Operations § 61.349 Standards: Closed-vent systems and control devices... efficiency of 95 weight percent or greater, or shall recover or control the benzene emissions vented to it..., or shall recover or control the benzene emissions vented to it with an efficiency of 98 weight...
40 CFR 63.983 - Closed vent systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Closed vent systems. 63.983 Section 63... Emission Standards for Closed Vent Systems, Control Devices, Recovery Devices and Routing to a Fuel Gas System or a Process § 63.983 Closed vent systems. (a) Closed vent system equipment and operating...
40 CFR 265.1088 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Closed-vent systems and control devices. 265.1088 Section 265.1088 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Containers § 265.1088 Standards: Closed-vent systems and control devices. (a) This section applies to each...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Closed vent systems and control... this part, except as provided in § 63.1002(b). (2) Owners or operators of closed vent systems and... in subpart SS of this part, except as provided in § 63.1002(b). (3) Owners or operators routing...
40 CFR 60.562-1 - Standards: Process emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Compound (VOC) Emissions from the Polymer Manufacturing Industry § 60.562-1 Standards: Process emissions... vent stream from a control device shall have car-sealed opened all valves in the vent system from the emission source to the control device and car-sealed closed all valves in vent system that would lead the...
40 CFR 60.692-5 - Standards: Closed vent systems and control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... residence time of 0.75 seconds at a minimum temperature of 816 °C (1,500 °F). (b) Vapor recovery systems... comply with provisions of this subpart shall be operated at all times when emissions may be vented to... purged to direct vapor to the control device. (3) A flow indicator shall be installed on a vent stream to...
40 CFR 60.692-5 - Standards: Closed vent systems and control devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... residence time of 0.75 seconds at a minimum temperature of 816 °C (1,500 °F). (b) Vapor recovery systems... comply with provisions of this subpart shall be operated at all times when emissions may be vented to... purged to direct vapor to the control device. (3) A flow indicator shall be installed on a vent stream to...
40 CFR 60.692-5 - Standards: Closed vent systems and control devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... residence time of 0.75 seconds at a minimum temperature of 816 °C (1,500 °F). (b) Vapor recovery systems... comply with provisions of this subpart shall be operated at all times when emissions may be vented to... purged to direct vapor to the control device. (3) A flow indicator shall be installed on a vent stream to...
40 CFR 60.692-5 - Standards: Closed vent systems and control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... residence time of 0.75 seconds at a minimum temperature of 816 °C (1,500 °F). (b) Vapor recovery systems... comply with provisions of this subpart shall be operated at all times when emissions may be vented to... purged to direct vapor to the control device. (3) A flow indicator shall be installed on a vent stream to...
Evaluation of aperture cover tank vent nozzles for the IRAS spacecraft
NASA Technical Reports Server (NTRS)
Richter, R.
1983-01-01
The influence of coefficients for the three axes of the Infrared Astronomical Satellite (IRAS) were established to determine the maximum allowable thrust difference between the two vent nozzles of the aperture cover tank low thrust vent system and their maximum misalignment. Test data generated by flow and torque measurements permitted the selection of two nozzles whose thrust differential was within the limit of the attitude control capability. Based on thrust stand data, a thrust vector misalignment was indicated that was slightly higher than permissible for the worst case, i.e., considerable degradation of the torque capacity of the attitude control system combined with venting of helium at its upper limit. The probability of destabilizing the IRAS spacecraft by activating the venting system appeared to be very low. The selection and mounting of the nozzles have satisfied all the requirements for the safe venting of helium.
Thermodynamic Vent System Test in a Low Earth Orbit Simulation
NASA Technical Reports Server (NTRS)
VanOverbeke, Thomas J.
2004-01-01
A thermodynamic vent system for a cryogenic nitrogen tank was tested in a vacuum chamber simulating oxygen storage in low earth orbit. The nitrogen tank was surrounded by a cryo-shroud at -40 F. The tank was insulated with two layers of multi-layer insulation. Heat transfer into cryogenic tanks causes phase change and increases tank pressure which must be controlled. A thermodynamic vent system was used to control pressure as the location of vapor is unknown in low gravity and direct venting would be wasteful. The thermodynamic vent system consists of a Joule-Thomson valve and heat exchanger installed on the inlet side of the tank mixer-pump. The combination is used to extract thermal energy from the tank fluid, reducing temperature and ullage pressure. The system was sized so that the tank mixer-pump operated a small fraction of the time to limit motor heating. Initially the mixer used sub-cooled liquid to cool the liquid-vapor interface inducing condensation and pressure reduction. Later, the thermodynamic vent system was used. Pressure cycles were performed until steady-state operation was demonstrated. Three test runs were conducted at tank fills of 97, 80, and 63 percent. Each test was begun with a boil-off test to determine heat transfer into the tank. The lower tank fills had time averaged vent rates very close to steady-state boil-off rates showing the thermodynamic vent system was nearly as efficient as direct venting in normal gravity.
40 CFR 65.140 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65..., shutdown, and malfunction provisions in § 65.6) apply to routing emissions to processes, fuel gas systems, closed vent systems, control devices, and recovery devices where another subpart expressly references the...
40 CFR 65.163 - Other records.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Detailed schematics, design specifications of the control device, and piping and instrumentation diagrams... FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65... bypass lines that could divert a vent stream away from the control device and to the atmosphere, the...
40 CFR 60.692-5 - Standards: Closed vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (for example, condensers and adsorbers) shall be designed and operated to recover the VOC emissions... systems and control devices. (a) Enclosed combustion devices shall be designed and operated to reduce the... them. (e)(1) Closed vent systems shall be designed and operated with no detectable emissions, as...
LH2 tank pressure control by thermodynamic vent system (TVS) at zero gravity
NASA Astrophysics Data System (ADS)
Wang, B.; Huang, Y. H.; Chen, Z. C.; Wu, J. Y.; Li, P.; Sun, P. J.
2017-02-01
Thermodynamic vent system (TVS) is employed for pressure control of propellant tanks at zero gravity. An analytical lumped parameter model is developed to predict pressure variation in an 18.09 m3 liquid hydrogen tank equipped with TVS. Mathematical simulations are carried out assuming tank is filled up to 75% volume (liquid mass equals to 945 kg) and is subjected to heat flux of 0.76 W/m2. Tank pressure controls at 165.5-172.4, 165.5-179.3 and 165.5-182.2 kPa are compared with reference to number of vent cycles, vent duration per cycle and loss of hydrogen. Analysis results indicate that the number of vent cycles significantly decreases from 62 to 21 when tank pressure control increases from 6.9 to 20.4 kPa. Also, duration of vent cycle increases from 63 to 152 and cycle duration decreases from 3920 to 3200 s. Further, the analysis result suggests that LH2 evaporation loss per day decreases from 0.17 to 0.14%. Based on the results of analysis, TVS is found effective in controlling the propellant tank pressure in zero gravity.
Improved inflatable landing systems for low cost planetary landers
NASA Astrophysics Data System (ADS)
Northey, Dave; Morgan, Chris
2006-10-01
Inflatable landing systems have been traditionally perceived as a cost-effective solution to the problem of landing a spacecraft on a planetary surface. To date, the systems used have all employed the approach of surrounding the lander with non-vented airbags where the lander on impact bounces a number of times until the impact energy is dissipated. However, the reliability record of such systems is not at all good. This paper examines the problems involved in the use of non-vented airbags, and how these problems have been overcome by the use of vented airbags in terrestrial systems. Using a specific case study, it is shown that even the basic passive type of venting can give significant mass reductions. It is also shown that actively controlling the venting based on the landing scenario can further enhance the performance of vented airbags.
Improved inflatable landing systems for low cost planetary landers
NASA Astrophysics Data System (ADS)
Northey, Dave; Morgan, Chris
2003-11-01
Inflatable landing systems have been traditionally perceived as a cost-effective solution to the problem of landing a spacecraft on a planetary surface. To date the systems used have all employed the approach of surrounding the lander with non-vented airbags where the lander bounces on impact a number of times until the impact energy is dissipated. However the reliability record of such systems is not at all good. This paper examines the problems involved in the use of non-vented airbags, and how these problems have been overcome by the use of vented airbags in terrestrial systems. Using a specific case study, it is shown that even the basic passive type of venting can give significant mass reductions. It is also shown that actively controlling the venting based on the landing scenario can further enhance the performance of vented airbags.
40 CFR 65.167 - Other reports.
Code of Federal Regulations, 2010 CFR
2010-07-01
... FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65... reporting and shall include a description of any changes made to the closed vent system. (b) Startup...
40 CFR 65.155 - Other control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.155 Other control devices. (a) Other control device equipment and operating requirements. (1... requirements specified in § 65.63(a)(2), or 40 CFR 60.562-1(a)(1)(i)(A) for process vents, or § 65.83(a)(1) for...
40 CFR 265.1033 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Closed-vent systems and control devices. 265.1033 Section 265.1033 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... total carbon working capacity -established as a requirement of § 265.1035(b)(4)(iii)(G), whichever is...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Standards: Closed vent systems and control devices; or emissions routed to a fuel gas system or process. 65.115 Section 65.115 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Equipment Leaks § 65.115 Standards:...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Closed vent systems and control devices; or emissions routed to a fuel gas system or process standards. 63.1034 Section 63.1034 Protection... stringent. The 20 parts per million by volume standard is not applicable to the provisions of § 63.1016. (ii...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Closed vent systems and control devices; or emissions routed to a fuel gas system or process standards. 63.1034 Section 63.1034 Protection... stringent. The 20 parts per million by volume standard is not applicable to the provisions of § 63.1016. (ii...
Controlled shutdown of a fuel cell
Clingerman, Bruce J.; Keskula, Donald H.
2002-01-01
A method is provided for the shutdown of a fuel cell system to relieve system overpressure while maintaining air compressor operation, and corresponding vent valving and control arrangement. The method and venting arrangement are employed in a fuel cell system, for instance a vehicle propulsion system, comprising, in fluid communication, an air compressor having an outlet for providing air to the system, a combustor operative to provide combustor exhaust to the fuel processor.
40 CFR 264.1033 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Closed-vent systems and control devices. 264.1033 Section 264.1033 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... no greater than 20 per-cent of the time required to con-sume the total carbon working cap-a-city...
40 CFR 65.152 - Carbon adsorbers used as control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... control device. If an owner or operator elects to replace a control device on a Group 1 process vent or... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Carbon adsorbers used as control... PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a...
40 CFR 65.150 - Absorbers used as control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...
40 CFR 65.150 - Absorbers used as control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...
40 CFR 65.150 - Absorbers used as control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...
46 CFR 56.50-85 - Tank-vent piping.
Code of Federal Regulations, 2011 CFR
2011-10-01
...-control systems or other, equivalent means, together with gauging devices and procedures for filling cargo... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Design Requirements Pertaining to Specific Systems § 56.50-85 Tank-vent piping. (a) This section...
40 CFR 63.136 - Process wastewater provisions-individual drain systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...
40 CFR 63.136 - Process wastewater provisions-individual drain systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...
40 CFR 63.136 - Process wastewater provisions-individual drain systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...
40 CFR 63.136 - Process wastewater provisions-individual drain systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Standards for Hazardous Air Pollutants: Site Remediation Closed Vent Systems and Control Devices § 63.7925...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Standards for Hazardous Air Pollutants: Site Remediation Closed Vent Systems and Control Devices § 63.7925...
40 CFR 49.4164 - Construction and operational control measures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... closed-vent system to: (i) An operating system designed to recover and inject all the produced natural... through a closed-vent system to: (i) An operating system designed to recover and inject the natural gas... operating system designed to recover and inject natural gas becomes temporarily infeasible and there is no...
40 CFR 49.4164 - Construction and operational control measures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... closed-vent system to: (i) An operating system designed to recover and inject all the produced natural... through a closed-vent system to: (i) An operating system designed to recover and inject the natural gas... operating system designed to recover and inject natural gas becomes temporarily infeasible and there is no...
Fuel cell system shutdown with anode pressure control
Clingerman, Bruce J.; Doan, Tien M.; Keskula, Donald H.
2002-01-01
A venting methodology and pressure sensing and vent valving arrangement for monitoring anode bypass valve operating during the normal shutdown of a fuel cell apparatus of the type used in vehicle propulsion systems. During a normal shutdown routine, the pressure differential between the anode inlet and anode outlet is monitored in real time in a period corresponding to the normal closing speed of the anode bypass valve and the pressure differential at the end of the closing cycle of the anode bypass valve is compared to the pressure differential at the beginning of the closing cycle. If the difference in pressure differential at the beginning and end of the anode bypass closing cycle indicates that the anode bypass valve has not properly closed, a system controller switches from a normal shutdown mode to a rapid shutdown mode in which the anode inlet is instantaneously vented by rapid vents.
40 CFR 63.693 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... recorder. One temperature sensor shall be installed in the vent stream at the nearest feasible point to the catalyst bed inlet and a second temperature sensor shall be installed in the vent stream at the nearest... temperature sensor must be ±1 percent of the temperature being measured, expressed in degrees Celsius or ±0.5...
40 CFR 63.693 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... recorder. One temperature sensor shall be installed in the vent stream at the nearest feasible point to the catalyst bed inlet and a second temperature sensor shall be installed in the vent stream at the nearest... temperature sensor must be ±1 percent of the temperature being measured, expressed in degrees Celsius or ±0.5...
40 CFR 63.693 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... recorder. One temperature sensor shall be installed in the vent stream at the nearest feasible point to the catalyst bed inlet and a second temperature sensor shall be installed in the vent stream at the nearest... temperature sensor must be ±1 percent of the temperature being measured, expressed in degrees Celsius or ±0.5...
40 CFR 63.693 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... recorder. One temperature sensor shall be installed in the vent stream at the nearest feasible point to the catalyst bed inlet and a second temperature sensor shall be installed in the vent stream at the nearest... temperature sensor must be ±1 percent of the temperature being measured, expressed in degrees Celsius or ±0.5...
40 CFR 63.693 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... recorder. One temperature sensor shall be installed in the vent stream at the nearest feasible point to the catalyst bed inlet and a second temperature sensor shall be installed in the vent stream at the nearest... temperature sensor must be ±1 percent of the temperature being measured, expressed in degrees Celsius or ±0.5...
46 CFR 154.1836 - Vapor venting as a means of cargo tank pressure and temperature control.
Code of Federal Regulations, 2013 CFR
2013-10-01
... temperature control. 154.1836 Section 154.1836 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... LIQUEFIED GASES Operations § 154.1836 Vapor venting as a means of cargo tank pressure and temperature... cargo pressure and temperature control system under §§ 154.701 through 154.709 is operating and that...
46 CFR 154.1836 - Vapor venting as a means of cargo tank pressure and temperature control.
Code of Federal Regulations, 2014 CFR
2014-10-01
... temperature control. 154.1836 Section 154.1836 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... LIQUEFIED GASES Operations § 154.1836 Vapor venting as a means of cargo tank pressure and temperature... cargo pressure and temperature control system under §§ 154.701 through 154.709 is operating and that...
46 CFR 154.1836 - Vapor venting as a means of cargo tank pressure and temperature control.
Code of Federal Regulations, 2012 CFR
2012-10-01
... temperature control. 154.1836 Section 154.1836 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... LIQUEFIED GASES Operations § 154.1836 Vapor venting as a means of cargo tank pressure and temperature... cargo pressure and temperature control system under §§ 154.701 through 154.709 is operating and that...
46 CFR 154.1836 - Vapor venting as a means of cargo tank pressure and temperature control.
Code of Federal Regulations, 2010 CFR
2010-10-01
... temperature control. 154.1836 Section 154.1836 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... LIQUEFIED GASES Operations § 154.1836 Vapor venting as a means of cargo tank pressure and temperature... cargo pressure and temperature control system under §§ 154.701 through 154.709 is operating and that...
46 CFR 154.1836 - Vapor venting as a means of cargo tank pressure and temperature control.
Code of Federal Regulations, 2011 CFR
2011-10-01
... temperature control. 154.1836 Section 154.1836 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... LIQUEFIED GASES Operations § 154.1836 Vapor venting as a means of cargo tank pressure and temperature... cargo pressure and temperature control system under §§ 154.701 through 154.709 is operating and that...
40 CFR 65.107 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... or fuel gas system or connected by a closed vent system to a control device that complies with the requirements of § 65.115; or (C) Equipped with a closed-loop system that purges the barrier fluid into a... section. (3) Routed to a process or fuel gas system or equipped with a closed vent system. Any pump that...
NASA Technical Reports Server (NTRS)
Flachbart, R. H.; Hastings, L. J.; Hedayat, A.; Nelson, S.; Tucker, S.
2006-01-01
In support of the development of a zero gravity pressure control capability for liquid hydrogen, testing was conducted at the Marshall Space Flight Center using the Multipurpose Hydrogen Test Bed (MHTB) to evaluate the effects of helium pressurant on the performance of a spray bar thermodynamic vent system (TVS). Fourteen days of testing was performed in August - September 2005, with an ambient heat leak of about 70-80 watts and tank fill levels of 90%, 50%, and 25%. The TVS successfully controlled the tank pressure within a +/- 3.45 kPa (+/- 0.5 psi) band with various helium concentration levels in the ullage. Relative to pressure control with an "all hydrogen" ullage, the helium presence resulted in 10 to 30 per cent longer pressure reduction durations, depending on the fill level, during the mixing/venting phase of the control cycle. Additionally, the automated control cycle was based on mixing alone for pressure reduction until the pressure versus time slope became positive, at which time the Joule-Thomson vent was opened. Testing was also conducted to evaluate thermodynamic venting without the mixer operating, first with liquid then with vapor at the recirculation line inlet. Although ullage stratification was present, the ullage pressure was successfully controlled without the mixer operating. Thus, if vapor surrounded the pump inlet in a reduced gravity situation, the ullage pressure can still be controlled by venting through the TVS Joule Thomson valve and heat exchanger. It was evident that the spray bar configuration, which extends almost the entire length of the tank, enabled significant thermal energy removal from the ullage even without the mixer operating. Details regarding the test setup and procedures are presented in the paper. 1
40 CFR 63.7188 - What are my monitoring installation, operation, and maintenance requirements?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Semiconductor Manufacturing Compliance Requirements § 63.7188 What are my monitoring installation, operation... emissions of your semiconductor process vent through a closed vent system to a control device, you must...
40 CFR 63.7188 - What are my monitoring installation, operation, and maintenance requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Semiconductor Manufacturing Compliance Requirements § 63.7188 What are my monitoring installation, operation... emissions of your semiconductor process vent through a closed vent system to a control device, you must...
Testing of an Ammonia EVA Vent Tool for the International Space Station
NASA Technical Reports Server (NTRS)
Ungar, Eugene K.; Stanewich, Brett J.; Wilhelm, Sheri Munekata
2000-01-01
When components of the International Space Station ammonia External Active Thermal Control System are replaced on-orbit, they must be vented immediately after removal from the system. Venting ensures that the component is not hard packed with liquid and thus does not pose a hazard. An extravehicular activity (EVA) vent tool has been developed to perform this function. However, there were concerns that the tool could whip, posing a hazard to the EVA astronaut, or would freeze. The ammonia vent tool was recently tested in a thermal/vacuum chamber to demonstrate that it would operate safely and would not freeze during venting. During the test, ammonia mimicking the venting conditions for six different heat exchanger initial conditions was passed through representative test articles. In the present work, the model that was used to develop the ammonia state and flow for the test points is discussed and the test setup and operation is described. The qualitative whipping and freezing results of the test are discussed and vent plume pressure measurements are described and interpreted.
40 CFR 63.107 - Identification of process vents subject to this subpart.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to this subpart. 63.107 Section 63.107 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... going to a fuel gas system as defined in § 63.101. (4) A gas stream exiting a control device used to... transfer operation vent subject to § 63.119 or § 63.126. (8) A vent from a waste management unit subject to...
40 CFR 60.482-10 - Standards: Closed vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Performance for Equipment Leaks of VOC in the Synthetic Organic Chemicals Manufacturing Industry for which... unit shutdown. (i) If a vapor collection system or closed vent system is operated under a vacuum, it is... would be exposed to an imminent or potential danger as a consequence of complying with paragraphs (f)(1...
Medium Fidelity Simulation of Oxygen Tank Venting
NASA Technical Reports Server (NTRS)
Sweet, Adam; Kurien, James; Lau, Sonie (Technical Monitor)
2001-01-01
The item to he cleared is a medium-fidelity software simulation model of a vented cryogenic tank. Such tanks are commonly used to transport cryogenic liquids such as liquid oxygen via truck, and have appeared on liquid-fueled rockets for decades. This simulation model works with the HCC simulation system that was developed by Xerox PARC and NASA Ames Research Center. HCC has been previously cleared for distribution. When used with the HCC software, the model generates simulated readings for the tank pressure and temperature as the simulated cryogenic liquid boils off and is vented. Failures (such as a broken vent valve) can be injected into the simulation to produce readings corresponding to the failure. Release of this simulation will allow researchers to test their software diagnosis systems by attempting to diagnose the simulated failure from the simulated readings. This model does not contain any encryption software nor can it perform any control tasks that might be export controlled.
40 CFR 63.1103 - Source category-specific applicability, definitions, and requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... separation of raw materials and by-products from the stabilized polymer. Front end process vent means any... vent systems, control devices, recovery devices, and routing to a fuel gas system or a process), as... allow worker access; passage of material into or out of the enclosure by conveyor, vehicles, or other...
40 CFR 63.1026 - Pumps in light liquid service standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... or fuel gas system or connected by a closed-vent system to a control device that complies with the requirements of either § 63.1034 or § 63.1021(b) of this part; or (C) Equipped with a closed-loop system that... paragraph (b) of this section. (3) Routed to a process or fuel gas system or equipped with a closed vent...
NASA Technical Reports Server (NTRS)
Peterson, Leslie D. (Inventor); Zimmermann, Richard E. (Inventor)
2001-01-01
An energy absorbing airbag system includes one or more vent valve assemblies for controlling the release of airbag inflation gases to maintain inflation gas pressure within an airbag at a substantially constant pressure during a ride-down of an energy absorbing event. Each vent valve assembly includes a cantilever spring that is flat in an unstressed condition and that has a free end portion. The cantilever spring is secured to an exterior surface of the airbag housing and flexed to cause the second free end portion of the cantilever spring to be pressed, with a preset force, against a vent port or a closure covering the vent port to seal the vent port until inflation gas pressure within the airbag reaches a preselected value determined by the preset force whereupon the free end portion of the cantilever spring is lifted from the vent port by the inflation gases within the airbag to vent the inflation gases from within the airbag. The resilience of the cantilever spring maintains a substantially constant pressure within the airbag during a ride-down portion of an energy absorbing event by causing the cantilever spring to vent gases through the vent port whenever the pressure of the inflation gases reaches the preselected value and by causing the cantilever spring to close the vent port whenever the pressure of the inflation gases falls below the preselected value.
2014-01-01
Background Root canal irrigation carries a risk of extrusion of irrigant into the periapical tissues which can be associated with pain, swelling, and tissue damage. Studies have shown less extrusion with sonic or apical negative pressure devices compared with syringe and side-port needle or passive ultrasonic irrigation with continuous irrigant flow. This study aimed to evaluate the effectiveness of the EndoVac irrigation system, regarding 1) debris removal and 2) the control of apically extruded irrigating solution. Methods Fifty extracted human single-rooted teeth were used in this study. The teeth were then randomly divided into three experimental groups according to the type of irrigation used and one control group. In group 1, irrigation was performed using the EndoVac irrigation system. In group 2, irrigation was performed using a 30-gauge, tip-vented irrigation needle. In group 3, irrigation was performed using a 30-gauge, side-vented irrigation needle. The control group received instrumentation with no irrigation to serve as a control for cleaning efficiency. Root canal instrumentation was performed using the Profile NiTi rotary system with a crown-down technique. All of the experimental teeth were irrigated with the same amount of 5.25% sodium hypochlorite. The amount of extruded irrigating solution was then measured by subtracting the post-instrumentation weight from the pre-instrumentation weight using an electronic balance. The cleanliness of debris removal was evaluated using scanning electron microscopy. Results EndoVac irrigation had the least amount of extrusion followed by the side-vented and tip-vented method. The difference between the groups was statistically significant (P <0.01). As for the cleaning results, the debris collection in the EndoVac and tip-vented groups was the least in the apical third. In the control and the side-vented groups, the debris was the greatest in the apical third, but this difference was not significant among the three experimental groups. Conclusions The EndoVac irrigation system extruded significantly less irrigant solution than either needle irrigation system. Debris collection was the least in the apical third for the EndoVac irrigation system. No significant difference was found in the cleaning efficiency among the three irrigation systems. PMID:24512441
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Halogenated Group 1 transfer operation vent stream for which you use a combustion device to control organic... your transfer operations. For each . . . You must. . . . 1. Group 1 transfer operation vent stream a... system to any combination of control devices (except a flare); or b. Reduce emissions of total organic...
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Halogenated Group 1 transfer operation vent stream for which you use a combustion device to control organic... your transfer operations. For each . . . You must. . . . 1. Group 1 transfer operation vent stream a... system to any combination of control devices (except a flare); or b. Reduce emissions of total organic...
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Halogenated Group 1 transfer operation vent stream for which you use a combustion device to control organic... your transfer operations. For each . . . You must. . . . 1. Group 1 transfer operation vent stream a... system to any combination of control devices (except a flare); or b. Reduce emissions of total organic...
Design of hydrogen vent line for the cryogenic hydrogen system in J-PARC
NASA Astrophysics Data System (ADS)
Tatsumoto, Hideki; Aso, Tomokazu; Kato, Takashi; Ohtsu, Kiichi; Hasegawa, Shoichi; Maekawa, Fujio; Futakawa, Masatoshi
2009-02-01
As one of the main experimental facilities in J-PARC, an intense spallation neutron source (JSNS) driven by a 1-MW proton beam selected supercritical hydrogen at a temperature of 20 K and a pressure of 1.5 MPa as a moderator material. Moderators are controlled by a cryogenic hydrogen system that has a hydrogen relief system, which consists of high and low pressure stage of manifolds, a hydrogen vent line and a stack, in order to release hydrogen to the outside safely. The design of the hydrogen vent line should be considered to prevent purge nitrogen gas in the vent line from freezing when releasing the cryogenic hydrogen, to prevent moisture in the stack placed in an outdoor location from freezing, and to inhibit large piping temperature reduction at a building wall penetration. In this work, temperature change behaviors in the hydrogen vent line were analyzed by using a CFD code, STAR-CD. We determined required sizes of the vent line based on the analytical results and its layout in the building.
40 CFR 60.482-10a - Standards: Closed vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Performance for Equipment Leaks of VOC in the Synthetic Organic Chemicals Manufacturing Industry for Which... vent system is operated under a vacuum, it is exempt from the inspection requirements of paragraphs (f... as a consequence of complying with paragraphs (f)(1)(i) or (f)(2) of this section; and (2) The owner...
NASA Technical Reports Server (NTRS)
Tutt, Ben; Gill, Susannah; Wilson, Aaron; Johnson, Keith
2009-01-01
Airborne Systems North America (formally Irvin Aerospace Inc) has developed an Airbag Landing System for the Orion Crew Module of the Crew Exploration Vehicle. This work is in support of the NASA Langley Research Center Landing System Advanced Development Project. Orion is part of the Constellation Program to send human explorers back to the moon, and then onwards to Mars and other destinations in the Solar System. A component of the Vision for Space Exploration, Orion is being developed to also enable access to space following the retirement of the Space Shuttle in the next decade. This paper documents the development of a conceptual design, fabrication of prototype assemblies, component level testing and two generations of airbag landing system testing. The airbag system has been designed and analyzed using the transient dynamic finite element code LS-DYNA(RegisteredTradeMark). The landing system consists of six airbag assemblies; each assembly comprising a primary impact venting airbag and a non-venting anti-bottoming airbag. The anti-bottoming airbag provides ground clearance following the initial impact attenuation sequence. Incorporated into each primary impact airbag is an active vent that allows the entrapped gas to exit the control volume. The size of the vent is tailored to control the flow-rate of the exiting gas. An internal shaping structure is utilized to control the shape of the primary or main airbags prior to ground impact; this significantly improves stroke efficiency and performance.
Analysis of sound absorption performance of an electroacoustic absorber using a vented enclosure
NASA Astrophysics Data System (ADS)
Cho, Youngeun; Wang, Semyung; Hyun, Jaeyub; Oh, Seungjae; Goo, Seongyeol
2018-03-01
The sound absorption performance of an electroacoustic absorber (EA) is primarily influenced by the dynamic characteristics of the loudspeaker that acts as the actuator of the EA system. Therefore, the sound absorption performance of the EA is maximum at the resonance frequency of the loudspeaker and tends to degrade in the low-frequency and high-frequency bands based on this resonance frequency. In this study, to adjust the sound absorption performance of the EA system in the low-frequency band of approximately 20-80 Hz, an EA system using a vented enclosure that has previously been used to enhance the radiating sound pressure of a loudspeaker in the low-frequency band, is proposed. To verify the usefulness of the proposed system, two acoustic environments are considered. In the first acoustic environment, the vent of the vented enclosure is connected to an external sound field that is distinct from the sound field coupled to the EA. In this case, the acoustic effect of the vented enclosure on the performance of the EA is analyzed through an analytical approach using dynamic equations and an impedance-based equivalent circuit. Then, it is verified through numerical and experimental approaches. Next, in the second acoustic environment, the vent is connected to the same external sound field as the EA. In this case, the effect of the vented enclosure on the EA is investigated through an analytical approach and finally verified through a numerical approach. As a result, it is confirmed that the characteristics of the sound absorption performances of the proposed EA system using the vented enclosure in the two acoustic environments considered in this study are different from each other in the low-frequency band of approximately 20-80 Hz. Furthermore, several case studies on the change tendency of the performance of the EA using the vented enclosure according to the critical design factors or vent number for the vented enclosure are also investigated. In the future, even if the proposed EA system using a vented enclosure is extended to a large number of arrays required for 3D sound field control, it is expected to be an attractive solution that can contribute to an improvement in low-frequency noise reduction without causing economic and system complexity problems.
Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine
NASA Technical Reports Server (NTRS)
Hurlbert, Eric A.; Romig, Kris A.; Jimenez, Rafael; Flores, Sam
2012-01-01
A report discusses a cryogenic reaction control system (RCS) that integrates a Joule-Thompson (JT) device (expansion valve) and thermodynamic vent system (TVS) with a cryogenic distribution system to allow fine control of the propellant quality (subcooled liquid) during operation of the device. It enables zero-venting when coupled with an RCS engine. The proper attachment locations and sizing of the orifice are required with the propellant distribution line to facilitate line conditioning. During operations, system instrumentation was strategically installed along the distribution/TVS line assembly, and temperature control bands were identified. A sub-scale run tank, full-scale distribution line, open-loop TVS, and a combination of procured and custom-fabricated cryogenic components were used in the cryogenic RCS build-up. Simulated on-orbit activation and thruster firing profiles were performed to quantify system heat gain and evaluate the TVS s capability to maintain the required propellant conditions at the inlet to the engine valves. Test data determined that a small control valve, such as a piezoelectric, is optimal to provide continuously the required thermal control. The data obtained from testing has also assisted with the development of fluid and thermal models of an RCS to refine integrated cryogenic propulsion system designs. This system allows a liquid oxygenbased main propulsion and reaction control system for a spacecraft, which improves performance, safety, and cost over conventional hypergolic systems due to higher performance, use of nontoxic propellants, potential for integration with life support and power subsystems, and compatibility with in-situ produced propellants.
40 CFR 63.11930 - What requirements must I meet for closed vent systems?
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission limits in Table 1 or 2 to this subpart to a control device, you must use a closed vent system and... emission limits in Table 1 or 2 to this subpart. You must maintain the records specified in paragraph (g)(1... (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE...
Ricevuto, E; Benedetti, M; Regoli, F; Spicer, J I; Gambi, M C
2015-12-01
Ocean acidification (OA) is occurring at a fast rate, resulting in changes of carbonate chemistry in the oceans and in lowering of the pH. Previous studies have documented significant changes in the antioxidant defenses of marine species in response to OA. Here, selected polychaete species, Platynereis dumerilii, Polyophthalmus pictus and Syllis prolifera, were sampled from a natural CO2 vent system (pH = 7.3) and from a non-venting 'control' site (pH = 8.1), and reciprocally transplanted in these areas for 30 days. Total antioxidant capacity toward different forms of oxyradicals was compared in native and transplanted polychaetes: the aim was to assess whether the environmental conditions at the vent site would act as a prooxidant stressor, and the capability of polychaetes to modulate their antioxidant capacity to counteract a varied oxyradicals formation. None of the investigated species enhanced the antioxidant potential during the experiment. A significant reduction of the capability to neutralize different forms of oxyradicals was observed in P. pictus and, partially, in S. prolifera when transplanted from control to naturally-acidified conditions. On the other hand, populations of P. dumerilii originating from the vent and of S. prolifera from both control and acidified sites, showed higher constitutive antioxidant efficiency toward peroxyl radicals and peroxynitrite, which may allow them to cope with short-term and chronic exposure to higher oxidative pressure without further enhancement of antioxidant defenses. Since low pH - high pCO2 is the greatest environmental difference between the control and the vent sites, we suggest that the pro-oxidant challenge due to such peculiarities may have different biological consequences in different polychaete species. Some appear more susceptible to oxidative effects, while others acquire a long term acclimatization to vent conditions through the enhancement of their basal antioxidant protection. Copyright © 2015 Elsevier Ltd. All rights reserved.
Shuttle Gaseous Hydrogen Venting Risk from Flow Control Valve Failure
NASA Technical Reports Server (NTRS)
Drummond, J. Philip; Baurle, Robert A.; Gafney, Richard L.; Norris, Andrew T.; Pellett, Gerald L.; Rock, Kenneth E.
2009-01-01
This paper describes a series of studies to assess the potential risk associated with the failure of one of three gaseous hydrogen flow control valves in the orbiter's main propulsion system during the launch of Shuttle Endeavour (STS-126) in November 2008. The studies focused on critical issues associated with the possibility of combustion resulting from release of gaseous hydrogen from the external tank into the atmosphere during assent. The Shuttle Program currently assumes hydrogen venting from the external tank will result in a critical failure. The current effort was conducted to increase understanding of the risk associated with venting hydrogen given the flow control valve failure scenarios being considered in the Integrated In-Flight Anomaly Investigation being conducted by NASA.
MSFC Skylab contamination control systems mission evaluation
NASA Technical Reports Server (NTRS)
1974-01-01
Cluster external contamination control evaluation was made throughout the Skylab Mission. This evaluation indicated that contamination control measures instigated during the design, development, and operational phases of this program were adequate to reduce the general contamination environment external to the Cluster below the threshold senstivity levels for experiments and affected subsystems. Launch and orbit contamination control features included eliminating certain vents, rerouting vents for minimum contamination impact, establishing filters, incorporating materials with minimum outgassing characteristics and developing operational constraints and mission rules to minimize contamination effects. Prior to the launch of Skylab, contamination control math models were developed which were used to predict Cluster surface deposition and background brightness levels throughout the mission. The report summarizes the Skylab system and experiment contamination control evaluation. The Cluster systems and experiments evaluated include Induced Atmosphere, Corollary and ATM Experiments, Thermal Control Surfaces, Solar Array Systems, Windows and Star Tracker.
Edmonds, H N; Michael, P J; Baker, E T; Connelly, D P; Snow, J E; Langmuir, C H; Dick, H J B; Mühe, R; German, C R; Graham, D W
2003-01-16
Submarine hydrothermal venting along mid-ocean ridges is an important contributor to ridge thermal structure, and the global distribution of such vents has implications for heat and mass fluxes from the Earth's crust and mantle and for the biogeography of vent-endemic organisms. Previous studies have predicted that the incidence of hydrothermal venting would be extremely low on ultraslow-spreading ridges (ridges with full spreading rates <2 cm x yr(-1)-which make up 25 per cent of the global ridge length), and that such vent systems would be hosted in ultramafic in addition to volcanic rocks. Here we present evidence for active hydrothermal venting on the Gakkel ridge, which is the slowest spreading (0.6-1.3 cm x yr(-1)) and least explored mid-ocean ridge. On the basis of water column profiles of light scattering, temperature and manganese concentration along 1,100 km of the rift valley, we identify hydrothermal plumes dispersing from at least nine to twelve discrete vent sites. Our discovery of such abundant venting, and its apparent localization near volcanic centres, requires a reassessment of the geologic conditions that control hydrothermal circulation on ultraslow-spreading ridges.
40 CFR 63.450 - Standards for enclosures and closed-vent systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
...-vent systems. 63.450 Section 63.450 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Standards for enclosures and closed-vent systems. (a) Each enclosure and closed-vent system specified in..., or repairs. (c) Each component of the closed-vent system used to comply with §§ 63.443(c), 63.444(b...
40 CFR 63.450 - Standards for enclosures and closed-vent systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
...-vent systems. 63.450 Section 63.450 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Standards for enclosures and closed-vent systems. (a) Each enclosure and closed-vent system specified in..., or repairs. (c) Each component of the closed-vent system used to comply with §§ 63.443(c), 63.444(b...
40 CFR 63.450 - Standards for enclosures and closed-vent systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
...-vent systems. 63.450 Section 63.450 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Standards for enclosures and closed-vent systems. (a) Each enclosure and closed-vent system specified in..., or repairs. (c) Each component of the closed-vent system used to comply with §§ 63.443(c), 63.444(b...
40 CFR 63.450 - Standards for enclosures and closed-vent systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-vent systems. 63.450 Section 63.450 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Standards for enclosures and closed-vent systems. (a) Each enclosure and closed-vent system specified in..., or repairs. (c) Each component of the closed-vent system used to comply with §§ 63.443(c), 63.444(b...
40 CFR 63.450 - Standards for enclosures and closed-vent systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
...-vent systems. 63.450 Section 63.450 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Standards for enclosures and closed-vent systems. (a) Each enclosure and closed-vent system specified in..., or repairs. (c) Each component of the closed-vent system used to comply with §§ 63.443(c), 63.444(b...
40 CFR 65.146 - Nonflare control devices used for equipment leaks only.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.146 Nonflare control devices used for equipment leaks only...
40 CFR 60.753 - Operational standards for collection and control systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... such that all collected gases are vented to a control system designed and operated in compliance with... and control systems. 60.753 Section 60.753 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Performance for Municipal Solid Waste Landfills § 60.753 Operational standards for collection and control...
40 CFR 60.753 - Operational standards for collection and control systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... such that all collected gases are vented to a control system designed and operated in compliance with... and control systems. 60.753 Section 60.753 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Performance for Municipal Solid Waste Landfills § 60.753 Operational standards for collection and control...
40 CFR 60.753 - Operational standards for collection and control systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... such that all collected gases are vented to a control system designed and operated in compliance with... and control systems. 60.753 Section 60.753 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Performance for Municipal Solid Waste Landfills § 60.753 Operational standards for collection and control...
40 CFR 63.1430 - Process vent reporting and recordkeeping requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... is subject to the Group 1 batch process vent control requirements for nonepoxide HAP emissions from...) Records to demonstrate compliance. The owner or operator complying with the process vent control...: (1) When using a flare to comply with the process vent control requirements in § 63.1425(b)(2)(i), (c...
NASA Astrophysics Data System (ADS)
Ludwig, K. A.; Kelley, D. S.; Butterfield, D. A.; Nelson, B. K.; Karson, J. A.
2003-12-01
The Lost City Hydrothermal Field (LCHF), at 30° N near the Mid-Atlantic Ridge, is an off-axis, low temperature, high-pH, ultramafic-hosted vent system. Within the field, carbonate chimneys tower up to 60 m above the seafloor, making them the tallest vent structures known. The chemistry of the vent structures and fluids at the LCHF is controlled by reactions between seawater and ultramafic rocks beneath the Atlantis massif. Mixing of warm alkaline vent fluids with seawater causes precipitation of calcium carbonate and growth of the edifaces, which range from tall, graceful pinnacles to fragile flanges and colloform deposits. Geochemical and petrological analyses of the carbonate rocks reveal distinct differences between the active and extinct structures. Actively venting chimneys and flanges are extremely porous, friable formations composed predominantly of aragonite and brucite. These structures provide important niches for well-developed microbial communities that thrive on and within the chimney walls. Some of the active chimneys may also contain the mineral ikaite, an unstable, hydrated form of calcium carbonate. TIMS and ICP-MS analyses of the carbonate chimneys show that the most active chimneys have low Sr isotope values and that they are low in trace metals (e.g., Mn, Ti, Pb). Active structures emit high-pH, low-Mg fluids at 40-90° C. The fluids also have low Sr values, indicating circulation of hydrothermal solutions through the serpentinite bedrock beneath the field. In contrast to the active structures, extinct chimneys are less porous, are well lithified, and they are composed predominantly of calcite that yields Sr isotopes near seawater values. Prolonged lower temperature seawater-hydrothermal fluid interaction within the chimneys results in the conversion of aragonite to calcite and in the enrichment of some trace metals (e.g., Mn, Ti, Co, Zn). It also promotes the incorporation of foraminifera within the outer, cemented walls of the carbonate structures. The Lost City system represents a novel natural laboratory for observing hydrothermal and biological activity in a system controlled by moderate temperature serpentinization reactions. The LCHF is the only vent field of its kind known to date; however, it is likely not unique along the global mid-ocean ridge spreading network.
Comparisons of volcanic eruptions from linear and central vents on Earth, Venus, and Mars (Invited)
NASA Astrophysics Data System (ADS)
Glaze, L. S.; Baloga, S. M.
2010-12-01
Vent geometry (linear versus central) plays a significant role in the ability of an explosive eruption to sustain a buoyant, convective plume. This has important implications for the injection and dispersal of particulates into planetary atmospheres and the ability to interpret the geologic record of planetary volcanism. The approach to modeling linear volcanic vents builds on the original work by Stothers [1], and takes advantage of substantial improvements that have been made in volcanic plume modeling over the last 20 years [e.g., 2,3]. A complete system of equations describing buoyant plume rise requires at least a half dozen differential equations and another half dozen equations for the parameters and constraints within the plume and ambient atmosphere. For the cylindrically axisymmetric system of differential equations given in [2], the control volume is defined as V = πr2dz. The area through which ambient atmosphere is entrained is Ae = 2πr dz, where r is the plume radius and z is vertical distance. The analogous linear vent system has a corresponding control volume, V = 2bLdz and entrainment area, Ae ≈ 2Ldz, where L is the length of the linear plume, 2b is the width of the linear plume, and it is assumed that L >> b. For typical terrestrial boundary conditions (temperature, velocity, gas mass fraction), buoyant plumes from circular vents can be maintained with substantial maximum heights over a wide range of vent sizes. However, linear vent plumes are much more sensitive to vent size, and can maintain a convective plume only over a much more narrow range of half widths. As L increases, linear plumes become more capable of establishing a convective regime over a broad range of bo, similar to the circular vents. This is primarily because as L increases, the entrainment area of the linear plumes increases, relative to the control volume. The ability of a plume to become buoyant is driven by whether or not sufficient air can be entrained (and warmed) to reduce the bulk plume density before upward momentum is exhausted. From mass conservation, linear plumes surpass circular vents in entrainment efficiency approximately when Lo ≥ 3ro. Consistent with other work [3,4], the range of conditions for maintaining a buoyant plume from a circular vent on Venus is very narrow, and the range of linear vent widths is more limited still. Unlike the terrestrial case, linear vents on Venus appear capable of driving a plume to somewhat higher maximum altitudes, with all other things remaining equal. Similar analyses were conducted for current atmospheric conditions on Mars. Results indicate a preference for the formation of pyroclastic flows on Mars from both circular and linear vents, as opposed to widely dispersed airfall deposits. Only the Earth, with its thick wet atmosphere, favors explosive eruptions that can maintain convective plumes reaching 10s of km in altitude over a broad range of eruptive conditions. References: [1] Stothers, R.B. (1989) J Atmos Sci, 46, 2662-2670. [2] Glaze. L.S., Baloga, S. M., and Wilson, L. (1997) JGR, 102, 6099-6108. [3] Glaze, L.S. (1999) JGR, 104, 18,899-18,906. [4] Thornhill, G.D. (1993) JGR, 98, 9107-9111.
46 CFR 153.354 - Venting system inlet.
Code of Federal Regulations, 2013 CFR
2013-10-01
... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.354 Venting system inlet. A venting system must terminate in the vapor space above the cargo...
46 CFR 153.354 - Venting system inlet.
Code of Federal Regulations, 2012 CFR
2012-10-01
... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.354 Venting system inlet. A venting system must terminate in the vapor space above the cargo...
46 CFR 153.354 - Venting system inlet.
Code of Federal Regulations, 2010 CFR
2010-10-01
... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.354 Venting system inlet. A venting system must terminate in the vapor space above the cargo...
46 CFR 153.354 - Venting system inlet.
Code of Federal Regulations, 2014 CFR
2014-10-01
... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.354 Venting system inlet. A venting system must terminate in the vapor space above the cargo...
46 CFR 153.354 - Venting system inlet.
Code of Federal Regulations, 2011 CFR
2011-10-01
... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Venting Systems § 153.354 Venting system inlet. A venting system must terminate in the vapor space above the cargo...
NASA Astrophysics Data System (ADS)
Wheeler, A. J.; Murton, B.; Copley, J.; Lim, A.; Carlsson, J.; Collins, P.; Dorschel, B.; Green, D.; Judge, M.; Nye, V.; Benzie, J.; Antoniacomi, A.; Coughlan, M.; Morris, K.
2013-10-01
Geological, biological, morphological, and hydrochemical data are presented for the newly discovered Moytirra vent field at 45oN. This is the only high temperature hydrothermal vent known between the Azores and Iceland, in the North Atlantic and is located on a slow to ultraslow-spreading mid-ocean ridge uniquely situated on the 300 m high fault scarp of the eastern axial wall, 3.5 km from the axial volcanic ridge crest. Furthermore, the Moytirra vent field is, unusually for tectonically controlled hydrothermal vents systems, basalt hosted and perched midway up on the median valley wall and presumably heated by an off-axis magma chamber. The Moytirra vent field consists of an alignment of four sites of venting, three actively emitting "black smoke," producing a complex of chimneys and beehive diffusers. The largest chimney is 18 m tall and vigorously venting. The vent fauna described here are the only ones documented for the North Atlantic (Azores to Reykjanes Ridge) and significantly expands our knowledge of North Atlantic biodiversity. The surfaces of the vent chimneys are occupied by aggregations of gastropods (Peltospira sp.) and populations of alvinocaridid shrimp (Mirocaris sp. with Rimicaris sp. also present). Other fauna present include bythograeid crabs (Segonzacia sp.) and zoarcid fish (Pachycara sp.), but bathymodiolin mussels and actinostolid anemones were not observed in the vent field. The discovery of the Moytirra vent field therefore expands the known latitudinal distributions of several vent-endemic genera in the north Atlantic, and reveals faunal affinities with vents south of the Azores rather than north of Iceland.
Development and relationship of monogenetic and polygenetic volcanic fields in time and space.
NASA Astrophysics Data System (ADS)
Germa, Aurelie; Connor, Chuck; Connor, Laura; Malservisi, Rocco
2013-04-01
The classification of volcanic systems, developed by G. P. L. Walker and colleagues, relates volcano morphology to magma transport and eruption processes. In general, distributed monogenetic volcanic fields are characterized by infrequent eruptions, low average output rate, and a low spatial intensity of the eruptive vents. In contrast, central-vent-dominated systems, such as stratovolcanoes, central volcanoes and lava shields are characterized by frequent eruptions, higher average flux rates, and higher spatial intensity of eruptive vents. However, it has been observed that a stratovolcano is often associated to parasitic monogenetic vents on its flanks, related to the central silicic systems, and surrounded by an apron of monogenetic edifices that are part of the volcanic field but independent from the principal central system. It appears from spatial distribution and time-volume relationships that surface area of monogenetic fields reflects the lateral extent of the magma source region and the lack of magma focusing mechanisms. In contrast, magma is focused through a unique conduit system for polygenetic volcanoes, provided by a thermally and mechanically favorable pathway toward the surface that is maintained by frequent and favorable stress conditions. We plan to relate surface observations of spatio-temporal location of eruptive vents and evolution of the field area through time to processes that control magma focusing during ascent and storage in the crust. We choose to study fields that range from dispersed to central-vent dominated, through transitional fields (central felsic system with peripheral field of monogenetic vents independent from the rhyolitic system). We investigate different well-studied volcanic fields in the Western US and Western Europe in order to assess influence of the geodynamic setting and tectonic stress on the spatial distribution of magmatism. In summary, incremental spatial intensity maps should reveal how fast a central conduit is created during the development of a volcanic field, and how this could influence the outbreak of dispersed monogenetic volcanoes that are not geochemically linked to the central system.
9 CFR 381.305 - Equipment and procedures for heat processing systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... plates. Whenever one or more divider plates are used between any two layers of containers or placed on... from several still retorts shall lead to the atmosphere. The manifold header shall not be controlled by...) Venting through multiple 1 inch (2.5 cm) vents discharging directly to the atmosphere. EC11SE91.047...
9 CFR 381.305 - Equipment and procedures for heat processing systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... plates. Whenever one or more divider plates are used between any two layers of containers or placed on... from several still retorts shall lead to the atmosphere. The manifold header shall not be controlled by...) Venting through multiple 1 inch (2.5 cm) vents discharging directly to the atmosphere. EC11SE91.047...
9 CFR 381.305 - Equipment and procedures for heat processing systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... plates. Whenever one or more divider plates are used between any two layers of containers or placed on... from several still retorts shall lead to the atmosphere. The manifold header shall not be controlled by...) Venting through multiple 1 inch (2.5 cm) vents discharging directly to the atmosphere. EC11SE91.047...
46 CFR 153.352 - B/3 and 4 m venting system outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false B/3 and 4 m venting system outlets. 153.352 Section 153.352 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES... Cargo Venting Systems § 153.352 B/3 and 4 m venting system outlets. A B/3 or 4 m venting system outlet...
46 CFR 153.352 - B/3 and 4 m venting system outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false B/3 and 4 m venting system outlets. 153.352 Section 153.352 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES... Cargo Venting Systems § 153.352 B/3 and 4 m venting system outlets. A B/3 or 4 m venting system outlet...
Measure Guideline. Steam System Balancing and Tuning for Multifamily Residential Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Jayne; Ludwig, Peter; Brand, Larry
2013-04-01
This guideline provides building owners, professionals involved in multifamily audits, and contractors insights for improving the balance and tuning of steam systems. It provides readers an overview of one-pipe steam heating systems, guidelines for evaluating steam systems, typical costs and savings, and guidelines for ensuring quality installations. It also directs readers to additional resources for details not included here. Measures for balancing a distribution system that are covered include replacing main line vents and upgrading radiator vents. Also included is a discussion on upgrading boiler controls and the importance of tuning the settings on new or existing boiler controls. Themore » guideline focuses on one-pipe steam systems, though many of the assessment methods can be generalized to two-pipe steam systems.« less
Beedessee, Girish; Watanabe, Hiromi; Ogura, Tomomi; Nemoto, Suguru; Yahagi, Takuya; Nakagawa, Satoshi; Nakamura, Kentaro; Takai, Ken; Koonjul, Meera; Marie, Daniel E. P.
2013-01-01
Dispersal ability plays a key role in the maintenance of species in spatially and temporally discrete niches of deep-sea hydrothermal vent environments. On the basis of population genetic analyses in the eastern Pacific vent fields, dispersal of animals in the mid-oceanic ridge systems generally appears to be constrained by geographical barriers such as trenches, transform faults, and microplates. Four hydrothermal vent fields (the Kairei and Edmond fields near the Rodriguez Triple Junction, and the Dodo and Solitaire fields in the Central Indian Ridge) have been discovered in the mid-oceanic ridge system of the Indian Ocean. In the present study, we monitored the dispersal of four representative animals, Austinograea rodriguezensis, Rimicaris kairei, Alviniconcha and the scaly-foot gastropods, among these vent fields by using indirect methods, i.e., phylogenetic and population genetic analyses. For all four investigated species, we estimated potentially high connectivity, i.e., no genetic difference among the populations present in vent fields located several thousands of kilometers apart; however, the direction of migration appeared to differ among the species, probably because of different dispersal strategies. Comparison of the intermediate-spreading Central Indian Ridge with the fast-spreading East Pacific Rise and slow-spreading Mid-Atlantic Ridge revealed the presence of relatively high connectivity in the intermediate- and slow-spreading ridge systems. We propose that geological background, such as spreading rate which determines distance among vent fields, is related to the larval dispersal and population establishment of vent-endemic animal species, and may play an important role in controlling connectivity among populations within a biogeographical province. PMID:24358117
SAMURAI: Polar AUV-Based Autonomous Dexterous Sampling
NASA Astrophysics Data System (ADS)
Akin, D. L.; Roberts, B. J.; Smith, W.; Roderick, S.; Reves-Sohn, R.; Singh, H.
2006-12-01
While autonomous undersea vehicles are increasingly being used for surveying and mapping missions, as of yet there has been little concerted effort to create a system capable of performing physical sampling or other manipulation of the local environment. This type of activity has typically been performed under teleoperated control from ROVs, which provides high-bandwidth real-time human direction of the manipulation activities. Manipulation from an AUV will require a completely autonomous sampling system, which implies both advanced technologies such as machine vision and autonomous target designation, but also dexterous robot manipulators to perform the actual sampling without human intervention. As part of the NASA Astrobiology Science and Technology for Exploring the Planets (ASTEP) program, the University of Maryland Space Systems Laboratory has been adapting and extending robotics technologies developed for spacecraft assembly and maintenance to the problem of autonomous sampling of biologicals and soil samples around hydrothermal vents. The Sub-polar ice Advanced Manipulator for Universal Sampling and Autonomous Intervention (SAMURAI) system is comprised of a 6000-meter capable six-degree-of-freedom dexterous manipulator, along with an autonomous vision system, multi-level control system, and sampling end effectors and storage mechanisms to allow collection of samples from vent fields. SAMURAI will be integrated onto the Woods Hole Oceanographic Institute (WHOI) Jaguar AUV, and used in Arctic during the fall of 2007 for autonomous vent field sampling on the Gakkel Ridge. Under the current operations concept, the JAGUAR and PUMA AUVs will survey the water column and localize on hydrothermal vents. Early mapping missions will create photomosaics of the vents and local surroundings, allowing scientists on the mission to designate desirable sampling targets. Based on physical characteristics such as size, shape, and coloration, the targets will be loaded into the SAMURAI control system, and JAGUAR (with SAMURAI mounted to the lower forward hull) will return to the designated target areas. Once on site, vehicle control will be turned over to the SAMURAI controller, which will perform vision-based guidance to the sampling site and will then ground the AUV to the sea bottom for stability. The SAMURAI manipulator will collect samples, such as sessile biologicals, geological samples, and (potentially) vent fluids, and store the samples for the return trip. After several hours of sampling operations on one or several sites, JAGUAR control will be returned to the WHOI onboard controller for the return to the support ship. (Operational details of AUV operations on the Gakkel Ridge mission are presented in other papers at this conference.) Between sorties, SAMURAI end effectors can be changed out on the surface for specific targets, such as push cores or larger biologicals such as tube worms. In addition to the obvious challenges in autonomous vision-based manipulator control from a free-flying support vehicle, significant development challenges have been the design of a highly capable robotic arm within the mass limitations (both wet and dry) of the JAGUAR vehicle, the development of a highly robust manipulator with modular maintenance units for extended polar operations, and the creation of a robot-based sample collection and holding system for multiple heterogeneous samples on a single extended sortie.
Occupancy-driven smart register for building energy saving (Conference Presentation)
NASA Astrophysics Data System (ADS)
Chen, Zhangjie; Wang, Ya S.
2017-04-01
The new era in energy-efficiency building is to integrate automatic occupancy detection with automated heating, ventilation and cooling (HVAC), the largest source of building energy consumption. By closing off some air vents, during certain hours of the day, up to 7.5% building energy consumption could be saved. In the past, smart vent has received increasing attention and several products have been developed and introduced to the market for building energy saving. For instance, Ecovent Systems Inc. and Keen Home Inc. have both developed smart vent registers capable of turning the vent on and off through smart phone apps. However, their products do not have on-board occupancy sensors and are therefore open-loop. Their vent control was achieved by simply positioning the vent blade through a motor and a controller without involving any smart actuation. This paper presents an innovative approach for automated vent control and automatic occupancy (human subjects) detection. We devise this approach in a smart register that has polydimethylsiloxane (PDMS) frame with embedded Shape memory alloy (SMA) actuators. SMAs belong to a class of shape memory materials (SMMs), which have the ability to `memorise' or retain their previous form when subjected to certain stimulus such as thermomechanical or magnetic variations. And it can work as actuators and be applied to vent control. Specifically, a Ni-Ti SMA strip will be pre-trained to a circular shape, wrapped with a Ni-Cr resistive wire that is coated with thermally conductive and electrically isolating material. Then, the SMA strip along with an antagonistic SMA strip will be bonded with PZT sensor and thermal sensors, to be inserted into a 3D printed mould which will be filled with silicone rubber materials. In the end, a demoulding process yields a fully integrated blade of the smart register. Several blades are installed together to form the smart register. The PZT sensors can feedback the shape of the actuator for precise shape and air flow control. The performance and the specification of the smart registers will be characterized experimentally. Its capacity of regulating airflow, forming air curtain will be demonstrated.
10 CFR 50.46a - Acceptance criteria for reactor coolant system venting systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Acceptance criteria for reactor coolant system venting... criteria for reactor coolant system venting systems. Each nuclear power reactor must be provided with high point vents for the reactor coolant system, for the reactor vessel head, and for other systems required...
10 CFR 50.46a - Acceptance criteria for reactor coolant system venting systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Acceptance criteria for reactor coolant system venting... criteria for reactor coolant system venting systems. Each nuclear power reactor must be provided with high point vents for the reactor coolant system, for the reactor vessel head, and for other systems required...
40 CFR 61.346 - Standards: Individual drain systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Each junction box shall be equipped with a cover and may have a vent pipe. The vent pipe shall be at least 90 cm (3 ft) in length and shall not exceed 10.2 cm (4 in) in diameter. (i) Junction box covers... inspection and maintenance. (ii) One of the following methods shall be used to control emissions from the...
40 CFR 61.346 - Standards: Individual drain systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Each junction box shall be equipped with a cover and may have a vent pipe. The vent pipe shall be at least 90 cm (3 ft) in length and shall not exceed 10.2 cm (4 in) in diameter. (i) Junction box covers... inspection and maintenance. (ii) One of the following methods shall be used to control emissions from the...
40 CFR 61.346 - Standards: Individual drain systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Each junction box shall be equipped with a cover and may have a vent pipe. The vent pipe shall be at least 90 cm (3 ft) in length and shall not exceed 10.2 cm (4 in) in diameter. (i) Junction box covers... inspection and maintenance. (ii) One of the following methods shall be used to control emissions from the...
The History of Venting (part I)
NASA Technical Reports Server (NTRS)
Leiter, Stephen C.
2017-01-01
Venting techniques and design are an important implementation strategy for observatory and payload contamination control, and yet venting analysis has seen a topsey turvey history, at lease from the perspective of the simple Layman trying to design a black box. Additionally, designing the vent has competing controls from Safety and EMIEMC. In the days of Shuttle, Safety placed liens against the vents of blankets, boxes, and large structural items principally to protect cargo bay vents but also from a flammability perspective. What continues to elude the Designer Community is a stable, simple way of designing vents for black boxes that satisfies everybody. But we continue to try.
40 CFR 63.491 - Batch front-end process vents-recordkeeping requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (b)(2): (i) For an incinerator or non-combustion control device, the percent reduction of organic HAP... the process vent stream is introduced with combustion air or is used as a secondary fuel and is not... combustion device to control halogenated batch front-end process vents or halogenated aggregate batch vent...
Loudspeakers: Modeling and control
NASA Astrophysics Data System (ADS)
Al-Ali, Khalid Mohammad
This thesis documented a comprehensive study of loudspeaker modeling and control. A lumped-parameter model for a voice-coil loudspeaker in a vented enclosure was presented that derived from a consideration of physical principles. In addition, a low-frequency (20 Hz to 100 Hz), feedback control method designed to improve the nonlinear performance of the loudspeaker and a suitable performance measure for use in design and evaluation were proposed. Data from experiments performed on a variety of actual loudspeakers confirmed the practicality of the theory developed in this work. The lumped-parameter loudspeaker model, although simple, captured much of the nonlinear behavior of the loudspeaker. In addition, the model formulation allowed a straightforward application of modern control system methods and lent itself well to modern parametric identification techniques. The nonlinear performance of the loudspeaker system was evaluated using a suitable distortion measure that was proposed and compared with other distortion measures currently used in practice. Furthermore, the linearizing effect of feedback using a linear controller (both static and dynamic) was studied on a class of nonlinear systems. The results illustrated that the distortion reduction was potentially significant and a useful upper bound on the closed-loop distortion was found based on the sensitivity function of the system's linearization. A feedback scheme based on robust control theory was chosen for application to the loudspeaker system. Using the pressure output of the loudspeaker system for feedback, the technique offered significant advantages over those previously attempted. Illustrative examples were presented that proved the applicability of the theory developed in this dissertation to a variety of loudspeaker systems. The examples included a vented loudspeaker model and actual loudspeakers enclosed in both vented and sealed configurations. In each example, predictable and measurable distortion reduction at the output of the closed-loop system was recorded.
33 CFR 183.520 - Fuel tank vent systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Fuel tank vent systems. 183.520...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.520 Fuel tank vent systems. (a) Each fuel tank must have a vent system that prevents pressure in the tank from exceeding 80...
33 CFR 183.520 - Fuel tank vent systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel tank vent systems. 183.520...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.520 Fuel tank vent systems. (a) Each fuel tank must have a vent system that prevents pressure in the tank from exceeding 80...
40 CFR 65.62 - Process vent group determination.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., or Group 2B) for each process vent. Group 1 process vents require control, and Group 2A and 2B... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Process vent group determination. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Process Vents § 65.62 Process vent group determination. (a) Group...
24 CFR 3280.710 - Venting, ventilation and combustion air.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Venting, ventilation and combustion... Fuel Burning Systems § 3280.710 Venting, ventilation and combustion air. (a) The venting as required by... appliance listing and the appliance manufacturer's instructions. (b) Venting and combustion air systems...
24 CFR 3280.710 - Venting, ventilation and combustion air.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Venting, ventilation and combustion... Fuel Burning Systems § 3280.710 Venting, ventilation and combustion air. (a) The venting as required by... appliance listing and the appliance manufacturer's instructions. (b) Venting and combustion air systems...
24 CFR 3280.710 - Venting, ventilation and combustion air.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Venting, ventilation and combustion... Fuel Burning Systems § 3280.710 Venting, ventilation and combustion air. (a) The venting as required by... appliance listing and the appliance manufacturer's instructions. (b) Venting and combustion air systems...
24 CFR 3280.710 - Venting, ventilation and combustion air.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Venting, ventilation and combustion... Fuel Burning Systems § 3280.710 Venting, ventilation and combustion air. (a) The venting as required by... appliance listing and the appliance manufacturer's instructions. (b) Venting and combustion air systems...
24 CFR 3280.710 - Venting, ventilation and combustion air.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Venting, ventilation and combustion... Fuel Burning Systems § 3280.710 Venting, ventilation and combustion air. (a) The venting as required by... appliance listing and the appliance manufacturer's instructions. (b) Venting and combustion air systems...
Explosive dome eruptions modulated by periodic gas-driven inflation
Johnson, Jeffrey B.; Lyons, John; Andrews, B. J.; Lees, J.M.
2014-01-01
Volcan Santiaguito (Guatemala) “breathes” with extraordinary regularity as the edifice's conduit system accumulates free gas, which periodically vents to the atmosphere. Periodic pressurization controls explosion timing, which nearly always occurs at peak inflation, as detected with tiltmeters. Tilt cycles in January 2012 reveal regular 26 ± 6 min inflation/deflation cycles corresponding to at least ~101 kg/s of gas fluxing the system. Very long period (VLP) earthquakes presage explosions and occur during cycles when inflation rates are most rapid. VLPs locate ~300 m below the vent and indicate mobilization of volatiles, which ascend at ~50 m/s. Rapid gas ascent feeds pyroclast-laden eruptions lasting several minutes and rising to ~1 km. VLPs are not observed during less rapid inflation episodes; instead, gas vents passively through the conduit producing no infrasound and no explosion. These observations intimate that steady gas exsolution and accumulation in shallow reservoirs may drive inflation cycles at open-vent silicic volcanoes.
Khan, Amjad; Dreier, Ken Wayne; Moulthrop, Lawrence Clinton; White, Erik James
2010-06-29
A system to vent a moist gas stream is disclosed. The system includes an enclosure and an electrochemical cell disposed within the enclosure, the electrochemical cell productive of the moist gas stream. A first vent is in fluid communication with the electrochemical cell for venting the moist gas stream to an exterior of the enclosure, and a second vent is in fluid communication with an interior of the enclosure and in thermal communication with the first vent for discharging heated air to the exterior of the enclosure. At least a portion of the discharging heated air is for preventing freezing of the moist gas stream within the first vent.
The potential hydrothermal systems unexplored in the Southwest Indian Ocean
NASA Astrophysics Data System (ADS)
Suo, Yanhui; Li, Sanzhong; Li, Xiyao; Zhang, Zhen; Ding, Dong
2017-06-01
Deep-sea hydrothermal vents possess complex ecosystems and abundant metallic mineral deposits valuable to human being. On-axial vents along tectonic plate boundaries have achieved prominent results and obtained huge resources, while nearly 90% of the global mid-ocean ridge and the majority of the off-axial vents buried by thick oceanic sediments within plates remain as relatively undiscovered domains. Based on previous detailed investigations, hydrothermal vents have been mapped along five sections along the Southwest Indian Ridge (SWIR) with different bathymetry, spreading rates, and gravity features, two at the western end (10°-16°E Section B and 16°-25°E Section C) and three at the eastern end (49°-52°E Section D, 52°-61°E Section E and 61°-70°E Section F). Hydrothermal vents along the Sections B, C, E and F with thin oceanic crust are hosted by ultramafic rocks under tectonic-controlled magmatic-starved settings, and hydrothermal vents along the Section D are associated with exceed magmatism. Limited coverage of investigations is provided along the 35°-47°E SWIR (between Marion and Indomed fracture zones) and a lot of research has been done around the Bouvet Island, while no hydrothermal vents has been reported. Analyzing bathymetry, gravity and geochemical data, magmatism settings are favourable for the occurrence of hydrothermal systems along these two sections. An off-axial hydrothermal system in the southern flank of the SWIR that exhibits ultra-thin oceanic crust associated with an oceanic continental transition is postulated to exist along the 100-Ma slow-spreading isochron in the Enderby Basin. A discrete, denser enriched or less depleted mantle beneath the Antarctic Plate is an alternative explanation for the large scale thin oceanic crust concentrated on the southern flank of the SWIR.
A serpentinite-hosted ecosystem in the Southern Mariana Forearc
NASA Astrophysics Data System (ADS)
Ohara, Yasuhiko; Reagan, Mark K.; Fujikura, Katsunori; Watanabe, Hiromi; Michibayashi, Katsuyoshi; Ishii, Teruaki; Stern, Robert J.; Pujana, Ignacio; Martinez, Fernando; Girard, Guillaume; Ribeiro, Julia; Brounce, Maryjo; Komori, Naoaki; Kino, Masashi
2012-02-01
Several varieties of seafloor hydrothermal vents with widely varying fluid compositions and temperatures and vent communities occur in different tectonic settings. The discovery of the Lost City hydrothermal field in the Mid-Atlantic Ridge has stimulated interest in the role of serpentinization of peridotite in generating H2- and CH4-rich fluids and associated carbonate chimneys, as well as in the biological communities supported in highly reduced, alkaline environments. Abundant vesicomyid clam communities associated with a serpentinite-hosted hydrothermal vent system in the southern Mariana forearc were discovered during a DSV Shinkai 6500 dive in September 2010. We named this system the "Shinkai Seep Field (SSF)." The SSF appears to be a serpentinite-hosted ecosystem within a forearc (convergent margin) setting that is supported by fault-controlled fluid pathways connected to the decollement of the subducting slab. The discovery of the SSF supports the prediction that serpentinite-hosted vents may be widespread on the ocean floor. The discovery further indicates that these serpentinite-hosted low-temperature fluid vents can sustain high-biomass communities and has implications for the chemical budget of the oceans and the distribution of abyssal chemosynthetic life.
A serpentinite-hosted ecosystem in the Southern Mariana Forearc
Ohara, Yasuhiko; Reagan, Mark K.; Fujikura, Katsunori; Watanabe, Hiromi; Michibayashi, Katsuyoshi; Ishii, Teruaki; Stern, Robert J.; Pujana, Ignacio; Martinez, Fernando; Girard, Guillaume; Ribeiro, Julia; Brounce, Maryjo; Komori, Naoaki; Kino, Masashi
2012-01-01
Several varieties of seafloor hydrothermal vents with widely varying fluid compositions and temperatures and vent communities occur in different tectonic settings. The discovery of the Lost City hydrothermal field in the Mid-Atlantic Ridge has stimulated interest in the role of serpentinization of peridotite in generating H2- and CH4-rich fluids and associated carbonate chimneys, as well as in the biological communities supported in highly reduced, alkaline environments. Abundant vesicomyid clam communities associated with a serpentinite-hosted hydrothermal vent system in the southern Mariana forearc were discovered during a DSV Shinkai 6500 dive in September 2010. We named this system the “Shinkai Seep Field (SSF).” The SSF appears to be a serpentinite-hosted ecosystem within a forearc (convergent margin) setting that is supported by fault-controlled fluid pathways connected to the decollement of the subducting slab. The discovery of the SSF supports the prediction that serpentinite-hosted vents may be widespread on the ocean floor. The discovery further indicates that these serpentinite-hosted low-temperature fluid vents can sustain high-biomass communities and has implications for the chemical budget of the oceans and the distribution of abyssal chemosynthetic life. PMID:22323611
A serpentinite-hosted ecosystem in the Southern Mariana Forearc.
Ohara, Yasuhiko; Reagan, Mark K; Fujikura, Katsunori; Watanabe, Hiromi; Michibayashi, Katsuyoshi; Ishii, Teruaki; Stern, Robert J; Pujana, Ignacio; Martinez, Fernando; Girard, Guillaume; Ribeiro, Julia; Brounce, Maryjo; Komori, Naoaki; Kino, Masashi
2012-02-21
Several varieties of seafloor hydrothermal vents with widely varying fluid compositions and temperatures and vent communities occur in different tectonic settings. The discovery of the Lost City hydrothermal field in the Mid-Atlantic Ridge has stimulated interest in the role of serpentinization of peridotite in generating H(2)- and CH(4)-rich fluids and associated carbonate chimneys, as well as in the biological communities supported in highly reduced, alkaline environments. Abundant vesicomyid clam communities associated with a serpentinite-hosted hydrothermal vent system in the southern Mariana forearc were discovered during a DSV Shinkai 6500 dive in September 2010. We named this system the "Shinkai Seep Field (SSF)." The SSF appears to be a serpentinite-hosted ecosystem within a forearc (convergent margin) setting that is supported by fault-controlled fluid pathways connected to the decollement of the subducting slab. The discovery of the SSF supports the prediction that serpentinite-hosted vents may be widespread on the ocean floor. The discovery further indicates that these serpentinite-hosted low-temperature fluid vents can sustain high-biomass communities and has implications for the chemical budget of the oceans and the distribution of abyssal chemosynthetic life.
40 CFR 65.156 - General monitoring requirements for control and recovery devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.156 General monitoring requirements for... systems. (1) All monitoring equipment shall be installed, calibrated, maintained, and operated according...
40 CFR 63.1322 - Batch process vents-reference control technology.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Batch process vents-reference control... (CONTINUED) National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins § 63.1322 Batch process vents—reference control technology. (a) Batch process vents. The owner or...
40 CFR 63.113 - Process vent provisions-reference control technology.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Process vent provisions-reference control technology. 63.113 Section 63.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 63.113 Process vent provisions—reference control technology. (a) The owner or operator of a Group 1...
40 CFR 63.113 - Process vent provisions-reference control technology.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Process vent provisions-reference control technology. 63.113 Section 63.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 63.113 Process vent provisions—reference control technology. (a) The owner or operator of a Group 1...
40 CFR 63.113 - Process vent provisions-reference control technology.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Process vent provisions-reference control technology. 63.113 Section 63.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 63.113 Process vent provisions—reference control technology. (a) The owner or operator of a Group 1...
40 CFR 63.113 - Process vent provisions-reference control technology.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Process vent provisions-reference control technology. 63.113 Section 63.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 63.113 Process vent provisions—reference control technology. (a) The owner or operator of a Group 1...
40 CFR 63.1322 - Batch process vents-reference control technology.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 12 2012-07-01 2011-07-01 true Batch process vents-reference control technology. 63.1322 Section 63.1322 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Batch process vents—reference control technology. (a) Batch process vents. The owner or operator of a...
40 CFR 63.1322 - Batch process vents-reference control technology.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Batch process vents-reference control technology. 63.1322 Section 63.1322 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... § 63.1322 Batch process vents—reference control technology. (a) Batch process vents. The owner or...
40 CFR 63.1322 - Batch process vents-reference control technology.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Batch process vents-reference control technology. 63.1322 Section 63.1322 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Batch process vents—reference control technology. (a) Batch process vents. The owner or operator of a...
40 CFR 63.1322 - Batch process vents-reference control technology.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Batch process vents-reference control technology. 63.1322 Section 63.1322 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Batch process vents—reference control technology. (a) Batch process vents. The owner or operator of a...
40 CFR 63.113 - Process vent provisions-reference control technology.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Process vent provisions-reference control technology. 63.113 Section 63.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 63.113 Process vent provisions—reference control technology. (a) The owner or operator of a Group 1...
Zero Gravity Cryogenic Vent System Concepts for Upper Stages
NASA Astrophysics Data System (ADS)
Ravex, Alain; Flachbart, Robin; Holt, Barney
The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space. Venting without resettling would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray bar system consists of a recirculation pump, a parallel flow concentric tube, heat exchanger, and a spray bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point, the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating boil-off losses. TVS performance testing demonstrated that the spray bar was effective in providing tank pressure control within a 6.89 kPa (1psi) band for fill levels of 90%, 50%, and 25%. Complete destratification of the liquid and ullage was achieved at these fill levels. The axial jet was effective in providing tank pressure control within the same pressure control band at the 90% fill level. However, at the 50% level, the system reached a point at which it was unable to extract enough energy to keep up with the heat leak into the tank. Due to a hardware problem, the recirculation pump operated well below the axial jet design flow rate. Therefore, it is likely that the performance of the axial jet would have improved had the pump operated at the proper flow rate. A CFD model is being used to determine if the desired axial jet performance would be achieved if a higher pump flow rate were available. Testing conducted thus far has demonstrated that both TVS concepts can be effective in destratifying a propellant tank, rejecting stored heat energy, and thus, controlling tank pressure.
14 CFR 29.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2014 CFR
2014-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 29.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 25.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2014 CFR
2014-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 29.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2013 CFR
2013-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 29.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 29.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2012 CFR
2012-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 25.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 25.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 25.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2012 CFR
2012-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 25.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2013 CFR
2013-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank vents and carburetor vapor vents...
Space LOX vent system. [for space shuttle orbiter
NASA Technical Reports Server (NTRS)
Erickson, R. C.
1975-01-01
This is the final report summarizing the work completed under contract NAS8-26972. Concept selection, design, fabricating and testing of a prototype compact heat exchanger thermodynamic vent system are discussed. The system is designed to operate in a 2.7m (9 foot) spherical liquid oxygen tank with a heating rate of 32.2 - 35.2 watts (110-120 Btu/hr) and to control pressure to 310 + or - 13.8 kN/sq m (45 + or - 2.0 psia.) the design mission is of 2,590 ks (30 days) duration on board a space shuttle orbiter.
Discovery of a black smoker vent field and vent fauna at the Arctic Mid-Ocean Ridge
Pedersen, Rolf B.; Rapp, Hans Tore; Thorseth, Ingunn H.; Lilley, Marvin D.; Barriga, Fernando J. A. S.; Baumberger, Tamara; Flesland, Kristin; Fonseca, Rita; Früh-Green, Gretchen L.; Jorgensen, Steffen L.
2010-01-01
The Arctic Mid-Ocean Ridge (AMOR) represents one of the most slow-spreading ridge systems on Earth. Previous attempts to locate hydrothermal vent fields and unravel the nature of venting, as well as the provenance of vent fauna at this northern and insular termination of the global ridge system, have been unsuccessful. Here, we report the first discovery of a black smoker vent field at the AMOR. The field is located on the crest of an axial volcanic ridge (AVR) and is associated with an unusually large hydrothermal deposit, which documents that extensive venting and long-lived hydrothermal systems exist at ultraslow-spreading ridges, despite their strongly reduced volcanic activity. The vent field hosts a distinct vent fauna that differs from the fauna to the south along the Mid-Atlantic Ridge. The novel vent fauna seems to have developed by local specialization and by migration of fauna from cold seeps and the Pacific. PMID:21119639
40 CFR 63.487 - Batch front-end process vents-reference control technology.
Code of Federal Regulations, 2010 CFR
2010-07-01
... § 63.487 Batch front-end process vents—reference control technology. (a) Batch front-end process vents... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Batch front-end process vents-reference control technology. 63.487 Section 63.487 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...
Using spacecraft trace contaminant control systems to cure sick building syndrome
NASA Technical Reports Server (NTRS)
Graf, John C.
1994-01-01
Many residential and commercial buildings with centralized, recirculating, heating ventilation and air conditioning systems suffer from 'Sick Building Syndrome.' Ventilation rates are reduced to save energy costs, synthetic building materials off-gas contaminants, and unsafe levels of volatile organic compounds (VOC's) accumulate. These unsafe levels of contaminants can cause irritation of eyes and throat, fatigue and dizziness to building occupants. Increased ventilation, the primary method of treating Sick Building Syndrome is expensive (due to increased energy costs) and recently, the effectiveness of increased ventilation has been questioned. On spacecraft venting is not allowed, so the primary methods of air quality control are; source control, active filtering, and destruction of VOC's. Four non-venting contaminant removal technologies; strict material selection to provide source control, ambient temperature catalytic oxidation, photocatalytic oxidation, and uptake by higher plants, may have potential application for indoor air quality control.
Giovannelli, Donato; d'Errico, Giuseppe; Manini, Elena; Yakimov, Michail; Vetriani, Costantino
2013-01-01
Studies of shallow-water hydrothermal vents have been lagging behind their deep-sea counterparts. Hence, the importance of these systems and their contribution to the local and regional diversity and biogeochemistry is unclear. This study analyzes the bacterial community along a transect at the shallow-water hydrothermal vent system of Milos island, Greece. The abundance and biomass of the prokaryotic community is comparable to areas not affected by hydrothermal activity and was, on average, 1.34 × 10(8) cells g(-1). The abundance, biomass and diversity of the prokaryotic community increased with the distance from the center of the vent and appeared to be controlled by the temperature gradient rather than the trophic conditions. The retrieved 16S rRNA gene fragments matched sequences from a variety of geothermal environments, although the average similarity was low (94%), revealing previously undiscovered taxa. Epsilonproteobacteria constituted the majority of the population along the transect, with an average contribution to the total diversity of 60%. The larger cluster of 16S rRNA gene sequences was related to chemolithoautotrophic Sulfurovum spp., an Epsilonproteobacterium so far detected only at deep-sea hydrothermal vents. The presence of previously unknown lineages of Epsilonproteobacteria could be related to the abundance of organic matter in these systems, which may support alternative metabolic strategies to chemolithoautotrophy. The relative contribution of Gammaproteobacteria to the Milos microbial community increased along the transect as the distance from the center of the vent increased. Further attempts to isolate key species from these ecosystems will be critical to shed light on their evolution and ecology.
Giovannelli, Donato; d'Errico, Giuseppe; Manini, Elena; Yakimov, Michail; Vetriani, Costantino
2013-01-01
Studies of shallow-water hydrothermal vents have been lagging behind their deep-sea counterparts. Hence, the importance of these systems and their contribution to the local and regional diversity and biogeochemistry is unclear. This study analyzes the bacterial community along a transect at the shallow-water hydrothermal vent system of Milos island, Greece. The abundance and biomass of the prokaryotic community is comparable to areas not affected by hydrothermal activity and was, on average, 1.34 × 108 cells g−1. The abundance, biomass and diversity of the prokaryotic community increased with the distance from the center of the vent and appeared to be controlled by the temperature gradient rather than the trophic conditions. The retrieved 16S rRNA gene fragments matched sequences from a variety of geothermal environments, although the average similarity was low (94%), revealing previously undiscovered taxa. Epsilonproteobacteria constituted the majority of the population along the transect, with an average contribution to the total diversity of 60%. The larger cluster of 16S rRNA gene sequences was related to chemolithoautotrophic Sulfurovum spp., an Epsilonproteobacterium so far detected only at deep-sea hydrothermal vents. The presence of previously unknown lineages of Epsilonproteobacteria could be related to the abundance of organic matter in these systems, which may support alternative metabolic strategies to chemolithoautotrophy. The relative contribution of Gammaproteobacteria to the Milos microbial community increased along the transect as the distance from the center of the vent increased. Further attempts to isolate key species from these ecosystems will be critical to shed light on their evolution and ecology. PMID:23847607
14 CFR 23.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2012 CFR
2012-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.975 Fuel tank vents and carburetor vapor vents. (a) Each fuel tank must be vented... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 23.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.975 Fuel tank vents and carburetor vapor vents. (a) Each fuel tank must be vented... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 23.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2014 CFR
2014-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.975 Fuel tank vents and carburetor vapor vents. (a) Each fuel tank must be vented... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 23.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2013 CFR
2013-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.975 Fuel tank vents and carburetor vapor vents. (a) Each fuel tank must be vented... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 23.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.975 Fuel tank vents and carburetor vapor vents. (a) Each fuel tank must be vented... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank vents and carburetor vapor vents...
40 CFR 52.1919 - Identification of plan-conditional approval.
Code of Federal Regulations, 2014 CFR
2014-07-01
... system vents and neutralization and distillation system vents (except wash kettle or still feed condenser... neutralization and distillation system vents. The revision lacked test procedures and record keeping requirements...
40 CFR 52.1919 - Identification of plan-conditional approval.
Code of Federal Regulations, 2013 CFR
2013-07-01
... system vents and neutralization and distillation system vents (except wash kettle or still feed condenser... neutralization and distillation system vents. The revision lacked test procedures and record keeping requirements...
Submergible barge retrievable storage and permanent disposal system for radioactive waste
Goldsberry, Fred L.; Cawley, William E.
1981-01-01
A submergible barge and process for submerging and storing radioactive waste material along a seabed. A submergible barge receives individual packages of radwaste within segregated cells. The cells are formed integrally within the barge, preferably surrounded by reinforced concrete. The cells are individually sealed by a concrete decking and by concrete hatch covers. Seawater may be vented into the cells for cooling, through an integral vent arrangement. The vent ducts may be attached to pumps when the barge is bouyant. The ducts are also arranged to promote passive ventilation of the cells when the barge is submerged. Packages of the radwaste are loaded into individual cells within the barge. The cells are then sealed and the barge is towed to the designated disposal-storage site. There, the individual cells are flooded and the barge will begin descent controlled by a powered submarine control device to the seabed storage site. The submerged barge will rest on the seabed permanently or until recovered by a submarine control device.
40 CFR 63.1032 - Sampling connection systems standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) [Reserved] (3) Be designed and operated to capture and transport all the purged process fluid to a control... (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 2 Standards § 63.1032 Sampling... design and operation. Each closed-purge, closed-loop, or closed vent system as required in paragraph (b...
40 CFR 63.1032 - Sampling connection systems standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) [Reserved] (3) Be designed and operated to capture and transport all the purged process fluid to a control... (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 2 Standards § 63.1032 Sampling... design and operation. Each closed-purge, closed-loop, or closed vent system as required in paragraph (b...
Test Data Analysis of a Spray Bar Zero-Gravity Liquid Hydrogen Vent System for Upper Stages
NASA Technical Reports Server (NTRS)
Hedayat, A.; Bailey, J. W.; Hastings, L. J.; Flachbart, R. H.
2003-01-01
To support development of a zero-gravity pressure control capability for liquid hydrogen (LH2), a series of thermodynamic venting system (TVS) tests was conducted in 1996 and 1998 using the Marshall Space Flight Center (MSFC) multipurpose hydrogen test bed (MHTB). These tests were performed with ambient heat leaks =20 and 50 W for tank fill levels of 90%, 50%, and 25%. TVS performance testing revealed that the spray bar was highly effective in providing tank pressure control within a 7-kPa band (131-138 Wa), and complete destratification of the liquid and the ullage was achieved with all test conditions. Seven of the MHTB tests were correlated with the TVS performance analytical model. The tests were selected to encompass the range of tank fill levels, ambient heat leaks, operational modes, and ullage pressurants. The TVS model predicted ullage pressure and temperature and bulk liquid saturation pressure and temperature obtained from the TVS model were compared with the test data. During extended self-pressurization periods, following tank lockup, the model predicted faster pressure rise rates than were measured. However, once the system entered the cyclic mixing/venting operational mode, the modeled and measured data were quite similar.
The paper describes a full-scale demonstration program in which several paint booths were modified for recirculation ventilation; the booth exhaust streams are vented to an innovative volatile organic compound (VOC) emission control system having extremely low operating costs. ...
NASA Astrophysics Data System (ADS)
White, S. M.
2018-05-01
New AUV-based mapping technology coupled with machine-learning methods for detecting individual vents and vent fields at the local-scale raise the possibility of understanding the geologic controls on hydrothermal venting.
Review and test of chilldown methods for space-based cryogenic tanks
NASA Astrophysics Data System (ADS)
Chato, David J.; Sanabria, Rafael
The literature for tank chilldown methods applicable to cryogenic tankage in the zero gravity environment of earth orbit is reviewed. One method is selected for demonstration in a ground based test. The method selected for investigation was the charge-hold-vent method which uses repeated injection of liquid slugs, followed by a hold to allow complete vaporization of the liquid and a vent of the tank to space vacuum to cool tankage to the desired temperature. The test was conducted on a 175 cubic foot, 2219 aluminum walled tank weighing 329 pounds, which was previously outfitted with spray systems to test nonvented fill technologies. To minimize hardware changes, a simple control-by-pressure scheme was implemented to control injected liquid quantities. The tank cooled from 440 R sufficiently in six charge-hold-vent cycles to allow a complete nonvented fill of the test tank. Liquid hydrogen consumed in the process is estimated at 32 pounds.
Review and test of chilldown methods for space-based cryogenic tanks
NASA Technical Reports Server (NTRS)
Chato, David J.; Sanabria, Rafael
1991-01-01
The literature for tank chilldown methods applicable to cryogenic tankage in the zero gravity environment of earth orbit is reviewed. One method is selected for demonstration in a ground based test. The method selected for investigation was the charge-hold-vent method which uses repeated injection of liquid slugs, followed by a hold to allow complete vaporization of the liquid and a vent of the tank to space vacuum to cool tankage to the desired temperature. The test was conducted on a 175 cubic foot, 2219 aluminum walled tank weighing 329 pounds, which was previously outfitted with spray systems to test nonvented fill technologies. To minimize hardware changes, a simple control-by-pressure scheme was implemented to control injected liquid quantities. The tank cooled from 440 R sufficiently in six charge-hold-vent cycles to allow a complete nonvented fill of the test tank. Liquid hydrogen consumed in the process is estimated at 32 pounds.
Hindcasting the paroxysmal eruption of Villarrica using resonant infrasound tones
NASA Astrophysics Data System (ADS)
Johnson, J. B.; Watson, L. M.; Dunham, E. M.; Anderson, J.; Franco, L.; Cardona, C., Sr.; Palma, J.
2017-12-01
Volcanoes radiate their most intense sounds in the infrasound band (below 20 Hz), which can be well recorded many kilometers from a vent. Open-vent volcanic systems, with active degassing, are particularly effective at producing infrasound, and they characteristically produce resonant tones controlled by the geometry of their crater. Changes in infrasound resonant tones, and their damping coefficient, thus provide a means to infer crater geometry, including crater volume, depth, and profile. This study analyzes the rapidly varying infrasound tone and quality factor of infrasound at Volcan Villarrica (Chile) leading up to its paroxysmal eruption on 3 March 2015. The changes in infrasound reflected a rise in the lava lake surface starting 100 hours prior to the violent and sudden eruption. We suggest that infrasound surveillance of open-vent resonance is a powerful tool with application for forecasting volcanic unrest at open vent volcanoes.
Spray Bar Zero-Gravity Vent System for On-Orbit Liquid Hydrogen Storage
NASA Technical Reports Server (NTRS)
Hastings, L. J.; Flachbart, R. H.; Martin, J. J.; Hedayat, A.; Fazah, M.; Lak, T.; Nguyen, H.; Bailey, J. W.
2003-01-01
During zero-gravity orbital cryogenic propulsion operations, a thermodynamic vent system (TVS) concept is expected to maintain tank pressure control without propellant resettling. In this case, a longitudinal spray bar mixer system, coupled with a Joule-Thompson (J-T) valve and heat exchanger, was evaluated in a series of TVS tests using the 18 cu m multipurpose hydrogen test bed. Tests performed at fill levels of 90, 50, and 25 percent, coupled with heat tank leaks of about 20 and 50 W, successfully demonstrated tank pressure control within a 7-kPa band. Based on limited testing, the presence of helium constrained the energy exchange between the gaseous and liquid hydrogen (LH2) during the mixing cycles. A transient analytical model, formulated to characterize TVS performance, was used to correlate the test data. During self-pressurization cycles following tank lockup, the model predicted faster pressure rise rates than were measured; however, once the system entered the cyclic self-pressurization/mixing/venting operational mode, the modeled and measured data were quite similar. During a special test at the 25-percent fill level, the J-T valve was allowed to remain open and successfully reduced the bulk LH2 saturation pressure from 133 to 70 kPa in 188 min.
An investigation of improved airbag performance by vent control and gas injection
NASA Astrophysics Data System (ADS)
Lee, Calvin; Rosato, Nick; Lai, Francis
Airbags are currently being investigated as an impact energy absorber for U.S. Army airdrop. Simple airbags with constant vent areas have been found to be unsatisfactory in yielding high G forces. In this paper, a method of controlling the vent area and a method of injecting gas into the airbag during its compression stroke to improve airbag performance are presented. Theoretical analysis of complex airbags using these two methods show that they provide lower G forces than simple airbags. Vertical drop tests of a vent-control airbag confirm this result. Gas-injection airbags are currently being tested.
Geochemistry of seafloor hydrothermal vent fluids at EPR 9°50'N: Time series data from 2004-2016
NASA Astrophysics Data System (ADS)
Scheuermann, P.; Pester, N. J.; Tutolo, B. M.; Simmons, S. F.; Seyfried, W. E., Jr.
2017-12-01
Hydrothermal fluids were collected from vent sites along the East Pacific Rise (EPR) at 9°50'N in 2004, 2008 and 2016 in isobaric gas-tight titanium samplers. These dates bracket the seafloor eruption that occurred at EPR 9°50'N between 2005 and 2006. The reported data focus on P vent and Bio9, as these vents were active during all three sampling periods. The concentration of aqueous volatiles reached maxima at both vents in 2008. At P vent, CO2, H2, and H2S were 124 mM/kg, 0.55 mM/kg and 12.2 mM/kg, respectively. The concentrations at Bio9 in 2008 were, 106 mM/kg CO2, 1.1 mM/kg H2, and 12.6 mM/kg H2S. Fe and Mn concentrations were the highest at both vent sites in 2004, and then decreased in 2008 and again in 2016. The range at P vent was 1.5-6.3 mM/kg Fe and 315-1212 uM/kg Mn, while at Bio9 the concentrations were 1.6-3.7 mM/kg Fe and 301-650 uM/kg Mn. The trends in CO2, H2, and H2S at P vent (2008 and 2016) and Bio9 (all years) are consistent with changes in subsurface pressure and temperature as a result of the eruption that alter the conditions at which dissolved components partition between vapor and liquid phases in the NaCl-H2O system. The trend in Fe and Mn concentrations is surprising and highlights the complex partitioning behavior of these elements in systems in which the concentrations are controlled by fluid-mineral equilibria as well as phase separation. Between 2004 and 2008, fluids at P vent transitioned from single-phase (535 mM/kg Cl) to a low-density vapor (370 mM/kg). Upon phase separation, the concentrations of H2S and H2 increased, while Fe and Mn concentrations decreased considerably. These changes highlight the importance of phase separation on controlling mass transfer from the crust to overlying ocean. In contrast to the other aqueous volatiles, CH4 concentrations in 2008 (47 µM) were lower or equal to concentrations in 2004 or 2016, 50-100 µM. CH4 is decoupled from the effects of phase separation, and is likely extracted from fluid inclusions in the host rock by circulating fluids. Li and CH4 concentrations follow similar patterns over time, supporting a rock-based source for CH4. That CO2 concentrations are elevated (relative to pre-eruption and 2016 values) up to two years after the eruption informs our understanding of the rates of heat and mass transfer in MOR hydrothermal systems.
40 CFR 270.305 - What tank information must I keep at my facility?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., bypass systems, and pressure controls (e.g., vents). (d) A diagram of piping, instrumentation, and process flow for each tank system. (e) A description of materials and equipment used to provide external...
40 CFR 270.305 - What tank information must I keep at my facility?
Code of Federal Regulations, 2012 CFR
2012-07-01
..., bypass systems, and pressure controls (e.g., vents). (d) A diagram of piping, instrumentation, and process flow for each tank system. (e) A description of materials and equipment used to provide external...
40 CFR 270.305 - What tank information must I keep at my facility?
Code of Federal Regulations, 2013 CFR
2013-07-01
..., bypass systems, and pressure controls (e.g., vents). (d) A diagram of piping, instrumentation, and process flow for each tank system. (e) A description of materials and equipment used to provide external...
40 CFR 270.305 - What tank information must I keep at my facility?
Code of Federal Regulations, 2014 CFR
2014-07-01
..., bypass systems, and pressure controls (e.g., vents). (d) A diagram of piping, instrumentation, and process flow for each tank system. (e) A description of materials and equipment used to provide external...
14 CFR 27.975 - Fuel tank vents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.975 Fuel tank vents. (a) Each fuel tank... system must be designed to minimize spillage of fuel through the vents to an ignition source in the event... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank vents. 27.975 Section 27.975...
14 CFR 27.975 - Fuel tank vents.
Code of Federal Regulations, 2014 CFR
2014-01-01
... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.975 Fuel tank vents. (a) Each fuel tank... system must be designed to minimize spillage of fuel through the vents to an ignition source in the event... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank vents. 27.975 Section 27.975...
14 CFR 27.975 - Fuel tank vents.
Code of Federal Regulations, 2013 CFR
2013-01-01
... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.975 Fuel tank vents. (a) Each fuel tank... system must be designed to minimize spillage of fuel through the vents to an ignition source in the event... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank vents. 27.975 Section 27.975...
14 CFR 27.975 - Fuel tank vents.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.975 Fuel tank vents. (a) Each fuel tank... system must be designed to minimize spillage of fuel through the vents to an ignition source in the event... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank vents. 27.975 Section 27.975...
14 CFR 27.975 - Fuel tank vents.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.975 Fuel tank vents. (a) Each fuel tank... system must be designed to minimize spillage of fuel through the vents to an ignition source in the event... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank vents. 27.975 Section 27.975...
NASA Astrophysics Data System (ADS)
Redfern, Andrew; Koplow, Michael; Wright, Paul
2007-01-01
Most residential heating, ventilating, and air-conditioning (HVAC) systems utilize a single zone for conditioning air throughout the entire house. While inexpensive, these systems lead to wide temperature distributions and inefficient cooling due to the difference in thermal loads in different rooms. The end result is additional cost to the end user because the house is over conditioned. To reduce the total amount of energy used in a home and to increase occupant comfort there is a need for a better control system using multiple temperature zones. Typical multi-zone systems are costly and require extensive infrastructure to function. Recent advances in wireless sensor networks (WSNs) have enabled a low cost drop-in wireless vent register control system. The register control system is controlled by a master controller unit, which collects sensor data from a distributed wireless sensor network. Each sensor node samples local settings (occupancy, light, humidity and temperature) and reports the data back to the master control unit. The master control unit compiles the incoming data and then actuates the vent resisters to control the airflow throughout the house. The control system also utilizes a smart thermostat with a movable set point to enable the user to define their given comfort levels. The new system can reduce the run time of the HVAC system and thus decreasing the amount of energy used and increasing the comfort of the home occupations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Production § 63.1426 Process vent requirements for determining organic HAP concentration, control efficiency..., total organic HAP, or as TOC minus methane and ethane according to the procedures specified. When... methane and ethane) concentrations in all process vent streams and primary and secondary fuels introduced...
Solar Thermal Upper Stage Cryogen System Engineering Checkout Test
NASA Technical Reports Server (NTRS)
Olsen, A. D; Cady, E. C.; Jenkins, D. S.
1999-01-01
The Solar Thermal Upper Stage technology (STUSTD) program is a solar thermal propulsion technology program cooperatively sponsored by a Boeing led team and by NASA MSFC. A key element of its technology program is development of a liquid hydrogen (LH2) storage and supply system which employs multi-layer insulation, liquid acquisition devices, active and passive thermodynamic vent systems, and variable 40W tank heaters to reliably provide near constant pressure H2 to a solar thermal engine in the low-gravity of space operation. The LH2 storage and supply system is designed to operate as a passive, pressure fed supply system at a constant pressure of about 45 psia. During operation of the solar thermal engine over a small portion of the orbit the LH2 storage and supply system propulsively vents through the enjoy at a controlled flowrate. During the long coast portion of the orbit, the LH2 tank is locked up (unvented). Thus, all of the vented H2 flow is used in the engine for thrust and none is wastefully vented overboard. The key to managing the tank pressure and therefore the H2 flow to the engine is to manage and balance the energy flow into the LH2 tank with the MLI and tank heaters with the energy flow out of the LH2 tank through the vented H2 flow. A moderate scale (71 cu ft) LH2 storage and supply system was installed and insulated at the NASA MSFC Test Area 300. The operation of the system is described in this paper. The test program for the LH2 system consisted of two parts: 1) a series of engineering tests to characterize the performance of the various components in the system: and 2) a 30-day simulation of a complete LEO and GEO transfer mission. This paper describes the results of the engineering tests, and correlates these results with analytical models used to design future advanced Solar Orbit Transfer Vehicles.
40 CFR 63.1406 - Reactor batch process vent provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Reactor batch process vent provisions... § 63.1406 Reactor batch process vent provisions. (a) Emission standards. Owners or operators of reactor... reactor batch process vent located at a new affected source shall control organic HAP emissions by...
40 CFR 63.1406 - Reactor batch process vent provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Reactor batch process vent provisions... § 63.1406 Reactor batch process vent provisions. (a) Emission standards. Owners or operators of reactor... reactor batch process vent located at a new affected source shall control organic HAP emissions by...
Automatic protective vent has fail-safe feature
NASA Technical Reports Server (NTRS)
Dameron, C. E.
1966-01-01
Delayed vent valve system in a mechanical backing pump in a vacuum system allows the pneumatic foreline valve to seal before the pump vent opens. The system is designed to be fail-safe and operate even though there is loss of electrical power.
40 CFR 63.1013 - Sampling connection systems standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Sampling connection systems standards... (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 1 § 63.1013 Sampling connection... sampling connection system shall be equipped with a closed purge, closed loop, or closed vent system...
Talking Fire Alarms Calm Kids.
ERIC Educational Resources Information Center
Executive Educator, 1984
1984-01-01
The new microprocessor-based fire alarm systems can help to control smoke movement throughout school buildings by opening vents and doors, identify the burning section, activate voice alarms, provide firefighters with telephone systems during the fire, and release fire-preventing gas. (KS)
Code of Federal Regulations, 2011 CFR
2011-07-01
... abatement or recovery device. Capture system means all equipment (including, but not limited to, hoods... translucent solid protective film. Closed vent system means a system that is not open to the atmosphere and is... evaporation of water. Condensate means volatile organic liquid separated from its associated gases, which...
40 CFR 264.1064 - Recordkeeping requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... management units in one recordkeeping system if the system identifies each record by each hazardous waste management unit. (b) Owners and operators must record the following information in the facility operating... monitoring, operating, and inspection information for each closed-vent system and control device required to...
Pressurization, Pneumatic, and Vent Subsystems of the X-34 Main Propulsion System
NASA Technical Reports Server (NTRS)
Hedayat, A.; Steadman, T. E.; Brown, T. M.; Knight, K. C.; White, C. E., Jr.; Champion, R. H., Jr.
1998-01-01
In pressurization systems, regulators and orifices are use to control the flow of the pressurant. For the X-34 Main Propulsion System, three pressurization subsystem design configuration options were considered. In the first option, regulators were used while in the other options, orifices were considered. In each design option, the vent/relief system must be capable of relieving the pressurant flow without allowing the tank pressure to rise above proof, therefore, impacts on the propellant tank vent system were investigated and a trade study of the pressurization system was conducted. The analysis indicated that design option using regulators poses least risk. Then, a detailed transient thermal/fluid analysis of the recommended pressurization system was performed. Helium usage, thermodynamic conditions, and overpressurization of each propellant tank were evaluated. The pneumatic and purge subsystem is used for pneumatic valve actuation, Inter-Propellant Seal purges, Engine Spin Start, and engine purges at the required interface pressures, A transient analysis of the pneumatic and purge subsystem provided helium usage and flow rates to Inter-Propellant Seal and engine interfaces. Fill analysis of the helium bottles of pressurization and pneumatic subsystems during ground operation was performed. The required fill time and the stored
The geochemical controls on vent fluids from the Lucky Strike vent field, Mid-Atlantic Ridge
NASA Astrophysics Data System (ADS)
Von Damm, K. L.; Bray, A. M.; Buttermore, L. G.; Oosting, S. E.
1998-08-01
Hydrothermal vent fluids were collected from the Lucky Strike site at 37°17'N on the Mid-Atlantic Ridge in both 1993 and 1996. Seven vents were sampled with the DSV Alvin in 1993 and six vents were sampled in 1996 using the ROV Jason during the LUSTRE '96 Cruise. As three of the vents were sampled in both 1993 and in 1996, a time series of vent fluid chemistry is also reported. Measured temperatures ranged from 202 to 333°C at the 1618-1726 m depth of the vent field, which is located on Lucky Strike Seamount. These fluids are either equal to or less than the local bottom seawater in chlorinity. While the range in fluid compositions at Lucky Strike is generally within that observed elsewhere, the unusual aspects of the fluid chemistries are the relatively high pH and low Fe, Mn, Li and Zn. We attribute this, as well as an usually low Sr/Ca ratio, to reaction with a highly altered substrate. The high Si and Cu contents suggest a deep, as well as hot, source for these fluids. The fluid compositions therefore suggest formation by super-critical phase separation at a depth not less than 1300 m below the seafloor, and reaction with a relatively oxic, and previously altered, substrate. There is temporal variability in some of the vent fluid compositions as Li, K, Ca and Fe concentrations have increased in some of the vents, as has the Fe/Mn (molar) ratio, although the chlorinities have remained essentially constant from 1993 to 1996. While there is not a simple relationship between vent fluid compositions (or temperatures) and distance from the lava lake at the summit of the seamount, the vent fluids from many of the vents can be shown to be related to others, often at distances >200 m. The most southeasterly vents (Eiffel Tower and the Marker/Mounds vents) are distinct in chlorinity and other chemical parameters from the rest of the vents, although closely related to each other within the southeastern area. Similarly all of the vents not in this one area, appear closely related to each other. This suggests one or two source fluids for many of the vents, as is also inferred to be the case at TAG, but which is in contrast to observations on faster spreading ridges. This may suggest inherently different plumbing for hydrothermal systems at slower versus faster spreading ridges.
Design and Testing of a Shell-Flow Hollow-Fiber Venting Gas Trap
NASA Technical Reports Server (NTRS)
Bue, Grant C.; Cross, Cindy; Hansen, Scott; Vogel, Matthew; Dillon, Paul
2013-01-01
A Venting Gas Trap (VGT) was designed, built, and tested at NASA Johnson Space Center to eliminate dissolved and free gas from the circulating coolant loop of the Orion Environmental Control Life Support System. The VGT was downselected from two different designs. The VGT has robust operation, and easily met all the Orion requirements, especially size and weight. The VGT has a novel design with the gas trap made of a five-layer spiral wrap of porous hydrophobic hollow fibers that form a cylindrically shaped curtain terminated by a dome-shaped distal plug. Circulating coolant flows into the center of the cylindrical curtain and flows between the hollow fibers, around the distal plug, and exits the VGT outlet. Free gas is forced by the coolant flow to the distal plug and brought into contact with hollow fibers. The proximal ends of the hollow fibers terminate in a venting chamber that allows for rapid venting of the free gas inclusion, but passively limits the external venting from the venting chamber through two small holes in the event of a long-duration decompression of the cabin. The VGT performance specifications were verified in a wide range of flow rates, bubble sizes, and inclusion volumes. Long-duration and integrated Orion human tests of the VGT are also planned for the coming year.
NASA Technical Reports Server (NTRS)
Majumdar, Alok; Valenzuela, Juan; LeClair, Andre; Moder, Jeff
2015-01-01
This paper presents a numerical model of a system-level test bed - the multipurpose hydrogen test bed (MHTB) using Generalized Fluid System Simulation Program (GFSSP). MHTB is representative in size and shape of a fully integrated space transportation vehicle liquid hydrogen (LH2) propellant tank and was tested at Marshall Space Flight Center (MSFC) to generate data for cryogenic storage. GFSSP is a finite volume based network flow analysis software developed at MSFC and used for thermo-fluid analysis of propulsion systems. GFSSP has been used to model the self-pressurization and ullage pressure control by Thermodynamic Vent System (TVS). A TVS typically includes a Joule-Thompson (J-T) expansion device, a two-phase heat exchanger, and a mixing pump and spray to extract thermal energy from the tank without significant loss of liquid propellant. Two GFSSP models (Self-Pressurization & TVS) were separately developed and tested and then integrated to simulate the entire system. Self-Pressurization model consists of multiple ullage nodes, propellant node and solid nodes; it computes the heat transfer through Multi-Layer Insulation blankets and calculates heat and mass transfer between ullage and liquid propellant and ullage and tank wall. TVS model calculates the flow through J-T valve, heat exchanger and spray and vent systems. Two models are integrated by exchanging data through User Subroutines of both models. The integrated models results have been compared with MHTB test data of 50% fill level. Satisfactory comparison was observed between test and numerical predictions.
40 CFR 63.137 - Process wastewater provisions-oil-water separators.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (2) The control device shall be designed, operated, and inspected in accordance with the requirements... receives, manages, or treats a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... control device. The fixed roof, closed-vent system, and control device shall meet the requirements...
40 CFR 63.137 - Process wastewater provisions-oil-water separators.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (2) The control device shall be designed, operated, and inspected in accordance with the requirements... receives, manages, or treats a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... control device. The fixed roof, closed-vent system, and control device shall meet the requirements...
40 CFR 63.137 - Process wastewater provisions-oil-water separators.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (2) The control device shall be designed, operated, and inspected in accordance with the requirements... receives, manages, or treats a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... control device. The fixed roof, closed-vent system, and control device shall meet the requirements...
Inskeep, William P.; Jay, Zackary J.; Macur, Richard E.; Clingenpeel, Scott; Tenney, Aaron; Lovalvo, David; Beam, Jacob P.; Kozubal, Mark A.; Shanks, W. C.; Morgan, Lisa A.; Kan, Jinjun; Gorby, Yuri; Yooseph, Shibu; Nealson, Kenneth
2015-01-01
Yellowstone Lake (Yellowstone National Park, WY, USA) is a large high-altitude (2200 m), fresh-water lake, which straddles an extensive caldera and is the center of significant geothermal activity. The primary goal of this interdisciplinary study was to evaluate the microbial populations inhabiting thermal vent communities in Yellowstone Lake using 16S rRNA gene and random metagenome sequencing, and to determine how geochemical attributes of vent waters influence the distribution of specific microorganisms and their metabolic potential. Thermal vent waters and associated microbial biomass were sampled during two field seasons (2007–2008) using a remotely operated vehicle (ROV). Sublacustrine thermal vent waters (circa 50–90°C) contained elevated concentrations of numerous constituents associated with geothermal activity including dissolved hydrogen, sulfide, methane and carbon dioxide. Microorganisms associated with sulfur-rich filamentous “streamer” communities of Inflated Plain and West Thumb (pH range 5–6) were dominated by bacteria from the Aquificales, but also contained thermophilic archaea from the Crenarchaeota and Euryarchaeota. Novel groups of methanogens and members of the Korarchaeota were observed in vents from West Thumb and Elliot's Crater (pH 5–6). Conversely, metagenome sequence from Mary Bay vent sediments did not yield large assemblies, and contained diverse thermophilic and nonthermophilic bacterial relatives. Analysis of functional genes associated with the major vent populations indicated a direct linkage to high concentrations of carbon dioxide, reduced sulfur (sulfide and/or elemental S), hydrogen and methane in the deep thermal ecosystems. Our observations show that sublacustrine thermal vents in Yellowstone Lake support novel thermophilic communities, which contain microorganisms with functional attributes not found to date in terrestrial geothermal systems of YNP. PMID:26579074
10 CFR 431.242 - Test Procedures [Reserved
Code of Federal Regulations, 2011 CFR
2011-01-01
... upstream of the draft control device of an individual, automatically operated, fossil fuel-fired appliance... intended for installation in the venting system of an individual, automatically operated, fossil fuel-fired...
10 CFR 431.242 - Test Procedures [Reserved
Code of Federal Regulations, 2010 CFR
2010-01-01
... upstream of the draft control device of an individual, automatically operated, fossil fuel-fired appliance... intended for installation in the venting system of an individual, automatically operated, fossil fuel-fired...
40 CFR 63.1032 - Sampling connection systems standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Sampling connection systems standards... (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 2 Standards § 63.1032 Sampling.... Each sampling connection system shall be equipped with a closed-purge, closed-loop, or closed vent...
Diverter bop system and method for a bottom supported offshore drilling rig
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roche, J. R.; Alexander, G. G.; Carbaugh, W. L.
1985-06-25
A system and method for installing a fluid flow controller and telescoping spools beneath an offshore bottom supported drilling rig rotary table is disclosed. Upper and lower telescoping spools are provided for initially connecting a Diverter/BOP convertible fluid flow controller between structural casing in the well and a permanent housing beneath the drilling rig rotary table. Clamp means are provided for clamping the rig vent line to an opening in the housing wall of the fluid flow controller during drilling of the borehole through the structural casing in preparation for setting and cementing the conductor casing. In that mode, themore » system is adapted as a diverter system. After the well is drilled for the conductor casing and the conductor casing is cemented and cut off at its top, a mandrel is fitted at the top of the conductor casing to which the lower end of the lower spool may be connected. The system may be used in this configuration as a diverter system, or after removal of the vent line and connection of a kill line to the housing outlet, the system may be used as a low pressure blowout preventer system.« less
40 CFR 65.112 - Standards: Compressors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... fuel gas system, or connected by a closed vent system to a control device that meets the requirements... barrier fluid system shall be equipped with a sensor that will detect failure of the seal system, barrier fluid system, or both. Each sensor shall be observed daily or shall be equipped with an alarm unless the...
40 CFR 63.1031 - Compressors standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... gas system or connected by a closed-vent system to a control device that meets the requirements of... service. Each barrier fluid system shall be equipped with a sensor that will detect failure of the seal system, barrier fluid system, or both. Each sensor shall be observed daily or shall be equipped with an...
40 CFR 65.112 - Standards: Compressors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... fuel gas system, or connected by a closed vent system to a control device that meets the requirements... barrier fluid system shall be equipped with a sensor that will detect failure of the seal system, barrier fluid system, or both. Each sensor shall be observed daily or shall be equipped with an alarm unless the...
40 CFR 63.1031 - Compressors standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... gas system or connected by a closed-vent system to a control device that meets the requirements of... service. Each barrier fluid system shall be equipped with a sensor that will detect failure of the seal system, barrier fluid system, or both. Each sensor shall be observed daily or shall be equipped with an...
Hydraulically-actuated operating system for an electric circuit breaker
Barkan, Philip; Imam, Imdad
1978-01-01
This hydraulically-actuated operating system comprises a cylinder, a piston movable therein in an opening direction to open a circuit breaker, and an accumulator for supplying pressurized liquid to a piston-actuating space within the cylinder. A normally-closed valve between the accumulator and the actuating space is openable to allow pressurized liquid from the accumulator to flow through the valve into the actuating space to drive the piston in an opening direction. A vent is located hydraulically between the actuating space and the valve for affording communication between said actuating space and a low pressure region. Flow control means is provided for restricting leakage through said vent to a rate that prevents said leakage from substantially detracting from the development of pressure within said actuatng space during the period from initial opening of the valve to the time when said piston has moved through most of its opening stroke. Following such period and while the valve is still open, said flow control means allows effective leakage through said vent. The accumulator has a limited capacity that results in the pressure within said actuating space decaying promptly to a low value as a result of effective leakage through said vent after the piston has moved through a circuit-breaker opening stroke and while the valve is in its open state. Means is provided for resetting the valve to its closed state in response to said pressure decay in the actuating space.
Staged venting of fuel cell system during rapid shutdown
Clingerman, Bruce J.; Doan, Tien M.; Keskula, Donald H.
2002-01-01
A venting methodology and system for rapid shutdown of a fuel cell apparatus of the type used in a vehicle propulsion system. H.sub.2 and air flows to the fuel cell stack are slowly bypassed to the combustor upon receipt of a rapid shutdown command. The bypass occurs over a period of time (for example one to five seconds) using conveniently-sized bypass valves. Upon receipt of the rapid shutdown command, the anode inlet of the fuel cell stack is instantaneously vented to a remote vent to remove all H.sub.2 from the stack. Airflow to the cathode inlet of the fuel cell stack gradually diminishes over the bypass period, and when the airflow bypass is complete the cathode inlet is also instantaneously vented to a remote vent to eliminate pressure differentials across the stack.
Staged venting of fuel cell system during rapid shutdown
Keskula, Donald H.; Doan, Tien M.; Clingerman, Bruce J.
2004-09-14
A venting methodology and system for rapid shutdown of a fuel cell apparatus of the type used in a vehicle propulsion system. H.sub.2 and air flows to the fuel cell stack are slowly bypassed to the combustor upon receipt of a rapid shutdown command. The bypass occurs over a period of time (for example one to five seconds) using conveniently-sized bypass valves. Upon receipt of the rapid shutdown command, the anode inlet of the fuel cell stack is instantaneously vented to a remote vent to remove all H.sub.2 from the stack. Airflow to the cathode inlet of the fuel cell stack gradually diminishes over the bypass period, and when the airflow bypass is complete the cathode inlet is also instantaneously vented to a remote vent to eliminate pressure differentials across the stack.
DSMC Simulations of Disturbance Torque to ISS During Airlock Depressurization
NASA Technical Reports Server (NTRS)
Lumpkin, F. E., III; Stewart, B. S.
2015-01-01
The primary attitude control system on the International Space Station (ISS) is part of the United States On-orbit Segment (USOS) and uses Control Moment Gyroscopes (CMG). The secondary system is part of the Russian On orbit Segment (RSOS) and uses a combination of gyroscopes and thrusters. Historically, events with significant disturbances such as the airlock depressurizations associated with extra-vehicular activity (EVA) have been performed using the RSOS attitude control system. This avoids excessive propulsive "de-saturations" of the CMGs. However, transfer of attitude control is labor intensive and requires significant propellant. Predictions employing NASA's DSMC Analysis Code (DAC) of the disturbance torque to the ISS for depressurization of the Pirs airlock on the RSOS will be presented [1]. These predictions were performed to assess the feasibility of using USOS control during these events. The ISS Pirs airlock is vented using a device known as a "T-vent" as shown in the inset in figure 1. By orienting two equal streams of gas in opposite directions, this device is intended to have no propulsive effect. However, disturbance force and torque to the ISS do occur due to plume impingement. The disturbance torque resulting from the Pirs depressurization during EVAs is estimated by using a loosely coupled CFD/DSMC technique [2]. CFD is used to simulate the flow field in the nozzle and the near field plume. DSMC is used to simulate the remaining flow field using the CFD results to create an in flow boundary to the DSMC simulation. Due to the highly continuum nature of flow field near the T-vent, two loosely coupled DSMC domains are employed. An 88.2 cubic meter inner domain contains the Pirs airlock and the T-vent. Inner domain results are used to create an in flow boundary for an outer domain containing the remaining portions of the ISS. Several orientations of the ISS solar arrays and radiators have been investigated to find cases that result in minimal disturbance torque. Figure 1 shows surface pressure contours on the ISS and a plane of number density contours for a particular case.
Independent Orbiter Assessment (IOA): Analysis of the purge, vent and drain subsystem
NASA Technical Reports Server (NTRS)
Bynum, M. C., III
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter PV and D (Purge, Vent and Drain) Subsystem hardware. The PV and D Subsystem controls the environment of unpressurized compartments and window cavities, senses hazardous gases, and purges Orbiter/ET Disconnect. The subsystem is divided into six systems: Purge System (controls the environment of unpressurized structural compartments); Vent System (controls the pressure of unpressurized compartments); Drain System (removes water from unpressurized compartments); Hazardous Gas Detection System (HGDS) (monitors hazardous gas concentrations); Window Cavity Conditioning System (WCCS) (maintains clear windows and provides pressure control of the window cavities); and External Tank/Orbiter Disconnect Purge System (prevents cryo-pumping/icing of disconnect hardware). Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Four of the sixty-two failure modes analyzed were determined as single failures which could result in the loss of crew or vehicle. A possible loss of mission could result if any of twelve single failures occurred. Two of the criticality 1/1 failures are in the Window Cavity Conditioning System (WCCS) outer window cavity, where leakage and/or restricted flow will cause failure to depressurize/repressurize the window cavity. Two criticality 1/1 failures represent leakage and/or restricted flow in the Orbiter/ET disconnect purge network which prevent cryopumping/icing of disconnect hardware. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.
46 CFR 153.351 - Location of 4m vent discharges.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Location of 4m vent discharges. 153.351 Section 153.351 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS... Venting Systems § 153.351 Location of 4m vent discharges. Except as prescribed in § 153.353, a 4m venting...
Turbofan Engine Core Compartment Vent Aerodynamic Configuration Development Methodology
NASA Technical Reports Server (NTRS)
Hebert, Leonard J.
2006-01-01
This paper presents an overview of the design methodology used in the development of the aerodynamic configuration of the nacelle core compartment vent for a typical Boeing commercial airplane together with design challenges for future design efforts. Core compartment vents exhaust engine subsystem flows from the space contained between the engine case and the nacelle of an airplane propulsion system. These subsystem flows typically consist of precooler, oil cooler, turbine case cooling, compartment cooling and nacelle leakage air. The design of core compartment vents is challenging due to stringent design requirements, mass flow sensitivity of the system to small changes in vent exit pressure ratio, and the need to maximize overall exhaust system performance at cruise conditions.
NASA Astrophysics Data System (ADS)
Schmidt, Katja; Garbe-Schönberg, Dieter; Hannington, Mark D.; Anderson, Melissa O.; Bühring, Benjamin; Haase, Karsten; Haruel, Christy; Lupton, John; Koschinsky, Andrea
2017-06-01
In 2013, high-temperature vent fluids were sampled in the Nifonea vent field. This field is located within the caldera of a large shield-type volcano of the Vate Trough, a young extensional rift in the New Hebrides back-arc. Hydrothermal venting occurs as clear and black smoker fluids with temperatures up to 368 °C, the hottest temperatures measured so far in the western Pacific. The physico-chemical conditions place the fluids within the two-phase field of NaCl-H2O, and venting is dominated by vapour phase fluids with Cl concentrations as low as 25 mM. The fluid composition, which differs between the individual vent sites, is interpreted to reflect the specific geochemical fluid signature of a hydrothermal system in its initial, post-eruptive stage. The strong Cl depletion is accompanied by low alkali/Cl ratios compared to more evolved hydrothermal systems, and very high Fe/Cl ratios. The concentrations of REY (180 nM) and As (21 μM) in the most Cl-depleted fluid are among the highest reported so far for submarine hydrothermal fluids, whereas the inter-element REY fractionation is only minor. The fluid signature, which has been described here for the first time in a back-arc setting, is controlled by fast fluid passage through basaltic volcanic rocks, with extremely high water-rock ratios and only limited water-rock exchange, phase separation and segregation, and (at least) two-component fluid mixing. Metals and metalloids are unexpectedly mobile in the vapour phase fluids, and the strong enrichments of Fe, REY, and As highlight the metal transport capacity of low-salinity, low-density vapours at the specific physico-chemical conditions at Nifonea. One possible scenario is that the fluids boiled before the separated vapour phase continued to react with fresh glassy lavas. The mobilization of metals is likely to occur by leaching from fresh glass and grain boundaries and is supported by the high water/rock ratios. The enrichment of B and As is further controlled by their high volatility, whereas the strong enrichment of REY is also a consequence of the elevated concentrations in the host rocks. However, a direct contribution of metals such as As from magmatic degassing cannot be ruled out. The different fluid end-member composition of individual vent sites could be explained by mixing of vapour phase fluids with another fluid phase of different water/rock interaction history.
40 CFR 49.143 - Construction and operational control measures.
Code of Federal Regulations, 2013 CFR
2013-07-01
...: (i) An operating system designed to recover and inject all the produced natural gas into a natural... closed-vent system to: (i) An operating system designed to recover and inject the natural gas emissions... that pipeline injection of all or part of the natural gas collected in an operating system designed to...
40 CFR 49.143 - Construction and operational control measures.
Code of Federal Regulations, 2014 CFR
2014-07-01
...: (i) An operating system designed to recover and inject all the produced natural gas into a natural... closed-vent system to: (i) An operating system designed to recover and inject the natural gas emissions... that pipeline injection of all or part of the natural gas collected in an operating system designed to...
40 CFR 65.107 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... frequency of drips and to the sensor that indicates failure of the seal system, the barrier fluid system, or... or fuel gas system or connected by a closed vent system to a control device that complies with the... equipped with a sensor that will detect failure of the seal system, the barrier fluid system, or both. (v...
Code of Federal Regulations, 2012 CFR
2012-01-01
... venting, external cooling by an ancillary system, or operational controls during transport. Natural...: The International System of Units (SI) followed or preceded by U.S. standard or customary units. The U... water as a common, contract, or private carrier, or by civil aircraft. Certificate holder means a person...
Code of Federal Regulations, 2011 CFR
2011-01-01
... venting, external cooling by an ancillary system, or operational controls during transport. Natural...: The International System of Units (SI) followed or preceded by U.S. standard or customary units. The U... water as a common, contract, or private carrier, or by civil aircraft. Certificate holder means a person...
Code of Federal Regulations, 2010 CFR
2010-01-01
... venting, external cooling by an ancillary system, or operational controls during transport. Natural...: The International System of Units (SI) followed or preceded by U.S. standard or customary units. The U... water as a common, contract, or private carrier, or by civil aircraft. Certificate holder means a person...
40 CFR 265.1035 - Recordkeeping requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... waste management units in one recordkeeping system if the system identifies each record by each... data supporting determinations of vent emissions and emission reductions achieved by add-on control... that result in maximum organic emissions, such as when the waste management unit is operating at the...
Assessment of Uinta Basin Oil and Natural Gas Well Pad ...
In the fall of 2016, a field study was conducted in the Uinta Basin Utah to improve information on oil and natural gas well pad pneumatic controllers (PCs) and emission measurement methods. A total of 80 PC systems at five oil sites (supporting six wells) and three gas sites (supporting 12 wells) were surveyed, and emissions data were produced using a combination of measurements and engineering emission estimates. Ninety-six percent of the PCs surveyed were the low actuation frequency intermittent vent type. The overall whole gas emission rate for the study was estimated at 0.37 scfh with the majority of emissions occurring from three continuous vent PCs (1.0 scfh average) and eleven (14%) malfunctioning intermittent vent PC systems (1.6 scfh average). Oil sites employed, on average 10.3 PC systems per well compared to 1.5 for gas sites. Oil and gas sites had group average PC emission rates of 0.28 scfh and 0.67 scfh, respectively, with this difference due in part to site selection procedures. The PC system types encountered, the engineering emissions estimate approach, and comparisons to measurements are described. Survey methods included identification of malfunctioning PC systems and emission measurements with augmented high volume sampling and installed mass flow meters, each providing a somewhat different picture of emissions that are elucidated through example cases. This paper reports on an oil and natural gas well pad pneumatic controller emissions stud
40 CFR 63.1007 - Pumps in light liquid service standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... sensor that indicates failure of the seal system, the barrier fluid system, or both. The owner or... reservoir that is routed to a process or fuel gas system or connected by a closed vent system to a control... liquid service. (iv) Each barrier fluid system is equipped with a sensor that will detect failure of the...
40 CFR 63.1007 - Pumps in light liquid service standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sensor that indicates failure of the seal system, the barrier fluid system, or both. The owner or... reservoir that is routed to a process or fuel gas system or connected by a closed vent system to a control... liquid service. (iv) Each barrier fluid system is equipped with a sensor that will detect failure of the...
40 CFR 63.1026 - Pumps in light liquid service standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... presence and frequency of drips and to the sensor that indicates failure of the seal system, the barrier... or fuel gas system or connected by a closed-vent system to a control device that complies with the.... (iv) Each barrier fluid system is equipped with a sensor that will detect failure of the seal system...
Low Gravity venting of Refrigerant 11
NASA Technical Reports Server (NTRS)
Labus, T. L.; Aydelott, J. C.; Lacovic, R. F.
1972-01-01
An experimental investigation was conducted in a five-second zero gravity facility to examine the effects of venting initially saturated Refrigerant 11 from a cylindrical container (15-cm diameter) under reduced gravitational conditions. The system Bond numbers studied were 0 (weightlessness), 9 and 63; the liquid exhibited a nearly zero-degree contact angle on the container surface. During the venting process, both liquid-vapor interface and liquid bulk vaporization occurred. The temperature of the liquid in the immediate vicinity of the liquid-vapor interface was found to decrease during venting, while the liquid bulk temperature remained constant. Qualitative observations of the effects of system acceleration, vent rate, and vapor volume presented. Quantitative information concerning the ullage pressure decay during low gravity venting is also included.
NASA Astrophysics Data System (ADS)
Inderbitzen, K. E.; Wheat, C. G.; Baker, P. A.; Fisher, A. T.
2014-12-01
Currently, fluid circulation patterns and the evolution of rock/fluid compositions as circulation occurs in subseafloor hydrothermal systems are poorly constrained. Sedimented spreading centers provide a unique opportunity to study subsurface flow because sediment acts as an insulating blanket that traps heat from the cooling magma body and limits: (a) potential flow paths for seawater to recharge the aquifer in permeable upper basaltic basement and (b) points of altered fluid egress. This also allows for a range of thermal and geochemical gradients to exist near the sediment-water interface. Models of fluid circulation patterns in this type of hydrologic setting have been generated (eg. Stein and Fisher, 2001); however fluid chemistry datasets have not previously been used to test the model's viability. We address this issue by integrating the existing circulation model with fluid compositional data collected from sediment pore waters and high temperature hydrothermal vents located in Middle Valley on the Juan de Fuca Ridge. Middle Valley hosts a variety of hydrologic regimes: including areas of fluid recharge (Site 855), active venting (Site 858/1036; Dead Dog vent field), recent venting (Site 856/1035; Bent Hill Massive Sulfide deposit) and a section of heavily sedimented basement located between recharge and discharge sites (Site 857). We will present new results based on thermal and geochemical data from the area of active venting (Sites 858 and 1036), that was collected during Ocean Drilling Program Legs 139 and 169 and a subsequent heat flow/gravity coring effort. These results illuminate fine scale controls on secondary recharge and fluid flow within the sediment section at Site 858/1036. The current status of high temperature vents in this area (based on observations made in July, 2014) will also be outlined.
Hydrothermal exploration and astrobiology: oases for life in distant oceans?
NASA Astrophysics Data System (ADS)
German, Christopher R.
2004-04-01
High-temperature submarine hydrothermal fields on Earth's mid-ocean ridges play host to exotic ecosystems with fauna previously unknown to science. Because these systems draw significant energy from chemosynthesis rather than photosynthesis, it has been postulated that the study of such systems could have relevance to the origins of life and, hence, astrobiology. A major flaw to that argument, however, is that modern basalt-hosted submarine vents are too oxidizing and lack the abundant free hydrogen required to drive abiotic organic synthesis and/or the energy yielding reactions that the most primitive anaerobic thermophiles isolated from submarine vent-sites apparently require. Here, however, the progress over the past decade in which systematic search strategies have been used to identify previously overlooked venting on the slow-spreading Mid-Atlantic Ridge and the ultra-slow spreading Arctic and SW Indian Ridges is described. Preliminary identification of fault-controlled venting in a number of these sites has led to the discovery of at least two high-temperature hydrothermal fields hosted in ultramafic rocks which emit complex organic molecules in their greater than 360 °C vent-fluids. Whether these concentrations represent de novo organic synthesis within the hydrothermal cell remains open to debate but it is probable that many more such sites exist throughout the Atlantic, Arctic and SW Indian Oceans. One particularly intriguing example is the Gakkel Ridge, which crosses the floor of the Arctic Ocean. On-going collaborations between oceanographers and astrobiologists are actively seeking to develop a new class of free-swimming autonomous underwater vehicle, equipped with appropriate chemical sensors, to conduct long-range missions that will seek out, locate and investigate new sites of hydrothermal venting at the bottom of this, and other, ice-covered oceans.
OPERATING PARAMETERS TO MINIMIZE EMISSIONS DURING ROTARY KILN EMERGENCY SAFETY VENT OPENINGS
Certain designs of hazardous waste incinerator systems include emergency safety vents (ESVs). ESVs (also called dump stacks, vent stacks, emergency by-pass stacks, thermal relief valves, and pressure relief valves) are regarded as true emergency devices. Their purpose is to vent ...
Bayraktarov, Elisa; Price, Roy E.; Ferdelman, Timothy G.; Finster, Kai
2013-01-01
Microbial sulfate reduction (SR) is a dominant process of organic matter mineralization in sulfate-rich anoxic environments at neutral pH. Recent studies have demonstrated SR in low pH environments, but investigations on the microbial activity at variable pH and CO2 partial pressure are still lacking. In this study, the effect of pH and pCO2 on microbial activity was investigated by incubation experiments with radioactive 35S targeting SR in sediments from the shallow-sea hydrothermal vent system of Milos, Greece, where pH is naturally decreased by CO2 release. Sediments differed in their physicochemical characteristics with distance from the main site of fluid discharge. Adjacent to the vent site (T ~40–75°C, pH ~5), maximal sulfate reduction rates (SRR) were observed between pH 5 and 6. SR in hydrothermally influenced sediments decreased at neutral pH. Sediments unaffected by hydrothermal venting (T ~26°C, pH ~8) expressed the highest SRR between pH 6 and 7. Further experiments investigating the effect of pCO2 on SR revealed a steep decrease in activity when the partial pressure increased from 2 to 3 bar. Findings suggest that sulfate reducing microbial communities associated with hydrothermal vent system are adapted to low pH and high CO2, while communities at control sites required a higher pH for optimal activity. PMID:23658555
Bayraktarov, Elisa; Price, Roy E; Ferdelman, Timothy G; Finster, Kai
2013-01-01
Microbial sulfate reduction (SR) is a dominant process of organic matter mineralization in sulfate-rich anoxic environments at neutral pH. Recent studies have demonstrated SR in low pH environments, but investigations on the microbial activity at variable pH and CO2 partial pressure are still lacking. In this study, the effect of pH and pCO2 on microbial activity was investigated by incubation experiments with radioactive (35)S targeting SR in sediments from the shallow-sea hydrothermal vent system of Milos, Greece, where pH is naturally decreased by CO2 release. Sediments differed in their physicochemical characteristics with distance from the main site of fluid discharge. Adjacent to the vent site (T ~40-75°C, pH ~5), maximal sulfate reduction rates (SRR) were observed between pH 5 and 6. SR in hydrothermally influenced sediments decreased at neutral pH. Sediments unaffected by hydrothermal venting (T ~26°C, pH ~8) expressed the highest SRR between pH 6 and 7. Further experiments investigating the effect of pCO2 on SR revealed a steep decrease in activity when the partial pressure increased from 2 to 3 bar. Findings suggest that sulfate reducing microbial communities associated with hydrothermal vent system are adapted to low pH and high CO2, while communities at control sites required a higher pH for optimal activity.
NASA Astrophysics Data System (ADS)
Crone, T. J.; Mittelstaedt, E. L.; Fornari, D. J.
2014-12-01
Fluid flow rates through high-temperature mid-ocean ridge hydrothermal vents are likely quite sensitive to poroelastic forcing mechanisms such as tidal loading and tectonic activity. Because poroelastic deformation and flow perturbations are estimated to extend to considerable depths within young oceanic crust, observations of flow rate changes at seafloor vents have the potential to provide constraints on the flow geometry and permeability structure of the underlying hydrothermal systems, as well as the quantities of heat and chemicals they exchange with overlying ocean, and the potential biological productivity of ecosystems they host. To help provide flow rate measurements in these challenging environments, we have developed two new optical flow oriented technologies. The first is a new form of Optical Plume Velocimetry (OPV) which relies on single-frame temporal cross-correlation to obtain time-averaged image velocity fields from short video sequences. The second is the VentCam, a deep sea camera system that can collect high-frame-rate video sequences at focused hydrothermal vents suitable for analysis with OPV. During the July 2014 R/V Atlantis/Alvin expedition to Axial Seamount, we deployed the VentCam at the ~300C Phoenix vent within the ASHES vent field and positioned it with DSRV Alvin. We collected 24 seconds of video at 50 frames per second every half-hour for approximately 10 days beginning July 22nd. We are currently applying single-frame lag OPV to these videos to estimate relative and absolute fluid flow rates through this vent. To explore the relationship between focused and diffuse venting, we deployed a second optical flow camera, the Diffuse Effluent Measurement System (DEMS), adjacent to this vent at a fracture within the lava carapace where low-T (~30C) fluids were exiting. This system collected video sequences and diffuse flow measurements at overlapping time intervals. Here we present the preliminary results of our work with VentCam and OPV, and comparisons with results from the DEMS camera.
NASA Astrophysics Data System (ADS)
Wang, Lei; Li, Yanzhong; Zhang, Feini; Ma, Yuan
2015-12-01
Two finite difference computer models, aiming at the process predictions of no-vent fill in normal gravity and microgravity environments respectively, are developed to investigate the filling performance in a liquid hydrogen (LH2) tank. In the normal gravity case model, the tank/fluid system is divided into five control volume including ullage, bulk liquid, gas-liquid interface, ullage-adjacent wall, and liquid-adjacent wall. In the microgravity case model, vapor-liquid thermal equilibrium state is maintained throughout the process, and only two nodes representing fluid and wall regions are applied. To capture the liquid-wall heat transfer accurately, a series of heat transfer mechanisms are considered and modeled successively, including film boiling, transition boiling, nucleate boiling and liquid natural convection. The two models are validated by comparing their prediction with experimental data, which shows good agreement. Then the two models are used to investigate the performance of no-vent fill in different conditions and several conclusions are obtained. It shows that in the normal gravity environment the no-vent fill experiences a continuous pressure rise during the whole process and the maximum pressure occurs at the end of the operation, while the maximum pressure of the microgravity case occurs at the beginning stage of the process. Moreover, it seems that increasing inlet mass flux has an apparent influence on the pressure evolution of no-vent fill process in normal gravity but a little influence in microgravity. The larger initial wall temperature brings about more significant liquid evaporation during the filling operation, and then causes higher pressure evolution, no matter the filling process occurs under normal gravity or microgravity conditions. Reducing inlet liquid temperature can improve the filling performance in normal gravity, but cannot significantly reduce the maximum pressure in microgravity. The presented work benefits the understanding of the no-vent fill performance and may guide the design of on-orbit no-vent fill system.
Insight from Genomics on Biogeochemical Cycles in a Shallow-Sea Hydrothermal System
NASA Astrophysics Data System (ADS)
Lu, G. S.; Amend, J.
2015-12-01
Shallow-sea hydrothermal ecosystems are dynamic, high-energy systems influenced by sunlight and geothermal activity. They provide accessible opportunities for investigating thermophilic microbial biogeochemical cycles. In this study, we report biogeochemical data from a shallow-sea hydrothermal system offshore Paleochori Bay, Milos, Greece, which is characterized by a central vent covered by white microbial mats with hydrothermally influenced sediments extending into nearby sea grass area. Geochemical analysis and deep sequencing provide high-resolution information on the geochemical patterns, microbial diversity and metabolic potential in a two-meter transect. The venting fluid is elevated in temperature (~70oC), low in pH (~4), and enriched in reduced species. The geochemical pattern shows that the profile is affected by not only seawater dilution but also microbial regulation. The microbial community in the deepest section of vent core (10-12 cm) is largely dominated by thermophilic archaea, including a methanogen and a recently described Crenarcheon. Mid-core (6-8 cm), the microbial community in the venting area switches to the hydrogen utilizer Aquificae. Near the sediment-water interface, anaerobic Firmicutes and Actinobacteria dominate, both of which are commonly associated with subsurface and hydrothermal sites. All other samples are dominated by diverse Proteobacteria. The sulfate profile is strongly correlated with the population size of delta- and episilon-proteobactia. The dramatic decrease in concentrations of As and Mn in pore fluids as a function of distance from the vent suggests that in addition to seawater dilution, microorganisms are likely transforming these and other ions through a combination of detoxification and catabolism. In addition, high concentrations of dissolved Fe are only measurable in the shallow sea grass area, suggesting that iron-transforming microorganisms are controlling Fe mobility, and promoting biomineralization. Taken together, these samples represent the effects of submarine venting on sediment microbial communities both vertically and horizontally in the predicted fluid flow path, and will provide a detailed investigation of genetic potential for biogeochemical cycling at Paleochori Bay.
Battery venting system and method
Casale, T.J.; Ching, L.K.W.; Baer, J.T.; Swan, D.H.
1999-01-05
Disclosed herein is a venting mechanism for a battery. The venting mechanism includes a battery vent structure which is located on the battery cover and may be integrally formed therewith. The venting mechanism includes an opening extending through the battery cover such that the opening communicates with a plurality of battery cells located within the battery case. The venting mechanism also includes a vent manifold which attaches to the battery vent structure. The vent manifold includes a first opening which communicates with the battery vent structure opening and second and third openings which allow the vent manifold to be connected to two separate conduits. In this manner, a plurality of batteries may be interconnected for venting purposes, thus eliminating the need to provide separate vent lines for each battery. The vent manifold may be attached to the battery vent structure by a spin-welding technique. To facilitate this technique, the vent manifold may be provided with a flange portion which fits into a corresponding groove portion on the battery vent structure. The vent manifold includes an internal chamber which is large enough to completely house a conventional battery flame arrester and overpressure safety valve. In this manner, the vent manifold, when installed, lessens the likelihood of tampering with the flame arrester and safety valve. 8 figs.
Battery venting system and method
Casale, Thomas J.; Ching, Larry K. W.; Baer, Jose T.; Swan, David H.
1999-01-05
Disclosed herein is a venting mechanism for a battery. The venting mechanism includes a battery vent structure which is located on the battery cover and may be integrally formed therewith. The venting mechanism includes an opening extending through the battery cover such that the opening communicates with a plurality of battery cells located within the battery case. The venting mechanism also includes a vent manifold which attaches to the battery vent structure. The vent manifold includes a first opening which communicates with the battery vent structure opening and second and third openings which allow the vent manifold to be connected to two separate conduits. In this manner, a plurality of batteries may be interconnected for venting purposes, thus eliminating the need to provide separate vent lines for each battery. The vent manifold may be attached to the battery vent structure by a spin-welding technique. To facilitate this technique, the vent manifold may be provided with a flange portion which fits into a corresponding groove portion on the battery vent structure. The vent manifold includes an internal chamber which is large enough to completely house a conventional battery flame arrester and overpressure safety valve. In this manner, the vent manifold, when installed, lessens the likelihood of tampering with the flame arrester and safety valve.
40 CFR 63.11516 - What are my standards and management practices?
Code of Federal Regulations, 2013 CFR
2013-07-01
... capture emissions and vent them to a filtration control device. You must operate the filtration control... requirement by maintaining a record of the manufacturer's specifications for the filtration control devices... to emit MFHAP. (1) You must capture emissions and vent them to a filtration control device. You must...
40 CFR 61.349 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the unit in accordance with good engineering and safety practices for handling flammable, explosive... device shall be made as soon as practicable but no later than 5 calendar days after detection. Repair...
40 CFR 61.349 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the unit in accordance with good engineering and safety practices for handling flammable, explosive... device shall be made as soon as practicable but no later than 5 calendar days after detection. Repair...
40 CFR 63.653 - Monitoring, recordkeeping, and implementation plan for emissions averaging.
Code of Federal Regulations, 2013 CFR
2013-07-01
... § 63.120 of subpart G; and (ii) For closed vent systems with control devices, conduct an initial design..., monitoring, recordkeeping, and reporting equivalent to that required for Group 1 emission points complying... control device. (2) The source shall implement the following procedures for each miscellaneous process...
Vented Launch Vehicle Adaptor for a Manned Spacecraft with "Pusher" Launch Abort System
NASA Technical Reports Server (NTRS)
Vandervort, Robert E. (Inventor)
2017-01-01
A system, method, and apparatus for a vented launch vehicle adaptor (LVA) for a manned spacecraft with a "pusher" launch abort system are disclosed. The disclosed LVA provides a structural interface between a commercial crew vehicle (CCV) crew module/service module (CM/SM) spacecraft and an expendable launch vehicle. The LVA provides structural attachment of the module to the launch vehicle. It also provides a means to control the exhaust plume from a pusher-type launch abort system that is integrated into the module. In case of an on-pad or ascent abort, which requires the module to jettison away from the launch vehicle, the launch abort system exhaust plume must be safely directed away from critical and dangerous portions of the launch vehicle in order to achieve a safe and successful jettison.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Definitions. 65.141 Section 65.141 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65...
Code of Federal Regulations, 2010 CFR
2010-07-01
... streams in open systems within a chemical manufacturing process unit. 63.149 Section 63.149 Protection of... open systems within a chemical manufacturing process unit. (a) The owner or operator shall comply with... Air Pollutants From the Synthetic Organic Chemical Manufacturing Industry for Process Vents, Storage...
Long-lived structural control of Mt. Shasta's plumbing system illuminated by 40Ar/39Ar geochronology
NASA Astrophysics Data System (ADS)
Calvert, A. T.; Christiansen, R. L.
2013-12-01
Mt. Shasta is the largest stratovolcano in the Cascade Arc, surpassed in volume only by the large rear-arc Medicine Lake and Newberry composite volcanoes. Including the material in the ~350 ka debris avalanche, it has produced more than 500 km3 of andesite and dacite from several superimposed central vents over its 700-850 kyr history. Earlier, between at least 970 to 1170 ka, the Rainbow Mountain volcano of similar composition and size occupied this latitude of the arc ~20 km further east. This shift of magmatic focus from within the arc axis (as defined by 6 Ma and younger calc-alkaline centers) to the arc front is poorly understood, but the current center's location appears structurally controlled. Most identifiable volcanic vents on Mt. Shasta lie within 1 km of a N-S line through the active summit cone. 40Ar/39Ar ages of map units occupying the vent alignment range from the Holocene (5×1 ka) current summit dome to at least the Middle Pleistocene (464×9 ka McKenzie Butte). The vast majority of eruptions have issued from central vents (Sargents Ridge, 300-135 ka; Misery Hill, 100-15 ka; and Hotlum, <10 ka), each 500 to 1000m north of its predecessor. A central vent for the pre-avalanche edifice is impossible to locate precisely, but was possibly on the same N-S trend and certainly no more than 4 km to the west, likely south of the Sargents Ridge central vent. ~15 of ~25 mapped flank vents lie on the alignment and the other ten lie west of the line. No identified volcanic vents lie east of the line until >12 km from Mt. Shasta (Ash Creek Butte, 227 ka; Basalt of McCloud River, 38 ka; The Whaleback, 102 ka), and monogenetic and polygenetic centers further east and northeast. From these observations we infer that: (1) magmas are localized along a ~20 km, long-lived, N-S trending structure running through the summit; (2) the upper crustal structure appears impermeable to magmas and resistant to dikes on its eastern side; (3) the western half of the area beneath the volcano appears substantially weaker, as dikes have fed flank vents 10-20 km from the summit over the history of the volcano; and (4) the orientation of the WNW-directed debris avalanche, coincident with the greatest concentration of flank vents, may indicate either structural weakness or failure following emplacement of a cryptodome similar to the 1980 events at Mt. St. Helens.
40 CFR Table 2 to Subpart Eeee of... - Emission Limits
Code of Federal Regulations, 2011 CFR
2011-07-01
... for combustion devices using supplemental combustion air, by venting emissions through a closed vent... concentration less than or equal to 20 ppmv, on a dry basis corrected to 3 percent oxygen for combustion devices using supplemental combustion air, by venting emissions through a closed vent system to any combination...
40 CFR 63.164 - Standards: Compressors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... process or fuel gas system or connected by a closed-vent system to a control device that complies with the... with a sensor that will detect failure of the seal system, barrier fluid system, or both. (e)(1) Each sensor as required in paragraph (d) of this section shall be observed daily or shall be equipped with an...
40 CFR 63.164 - Standards: Compressors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... process or fuel gas system or connected by a closed-vent system to a control device that complies with the... with a sensor that will detect failure of the seal system, barrier fluid system, or both. (e)(1) Each sensor as required in paragraph (d) of this section shall be observed daily or shall be equipped with an...
40 CFR 60.482-3 - Standards: Compressors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... process or fuel gas system or connected by a closed vent system to a control device that complies with the... be equipped with a sensor that will detect failure of the seal system, barrier fluid system, or both. (e)(1) Each sensor as required in paragraph (d) shall be checked daily or shall be equipped with an...
40 CFR 60.482-3 - Standards: Compressors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... process or fuel gas system or connected by a closed vent system to a control device that complies with the... be equipped with a sensor that will detect failure of the seal system, barrier fluid system, or both. (e)(1) Each sensor as required in paragraph (d) shall be checked daily or shall be equipped with an...
40 CFR 264.1033 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... condenser exit (i.e., product side). (vii) For a carbon adsorption system that regenerates the carbon bed... requirements of this section. (g) An owner or operator using a -carbon adsorption system such as a fixed-bed...)(F). (h) An owner or operator using a carbon adsorption system such as a carbon canister that does...
NASA Astrophysics Data System (ADS)
Carbone, Daniele; Poland, Michael; Patrick, Matthew
2015-04-01
We find a tight correlation between (i) changes in lava level within the summit eruptive vent at Kilauea Volcano, Hawaii, observed for at least 2 years since early 2011, and (ii) ground deformation in the vicinity of the vent. The observed correlation indicates that changing pressure within the shallow magma reservoir feeding the lava lake influences both deformation and lava level. However, those two parameters are related to chamber pressure through different properties, namely, the density of the lava filling the vent (for the lava level) and the size/position of the reservoir plus the elastic parameters of the host rock (for the deformation). Joint analyses in the time and frequency domains of lava level (determined from thermal camera imagery of the lava lake) and tilt measured on a borehole instrument (~2 km from the summit vent) reveal a good correlation throughout the studied period. The highest correlation occurs over periods ranging between 1 and 20 days. The ratio between lava level and tilt is not constant over time, however. Using data from a continuously recording gravimeter located near the rim of the summit eruptive vent, we demonstrate that the tilt-lava level ratio is controlled by the fluctuations in the density of the lava inside the vent (i.e., its degree of vesicularity). A second continuous gravimeter was installed near the summit eruptive vent in 2014, providing a new observation point for gravity change associated with summit lava lave activity to test models developed from the previously existing instrument. In addition, a continuous gravimeter was installed on the rim of the Puu Oo eruptive vent on Kilauea's East Rift Zone in 2013. Puu Oo is connected via the subvolcanic magma plumbing system to the summit eruptive vent and often deforms in concert with the summit. This growing network of continuously recording gravimeters at Kilauea can be used to examine correlations in gravity change associated with variations in eruptive activity across the volcano.
40 CFR 63.172 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Enclosed combustion devices shall be designed and operated to reduce the organic hazardous air pollutant... non-diverting position with a car-seal or a lock-and-key type configuration. A visual inspection of...
40 CFR 63.172 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Enclosed combustion devices shall be designed and operated to reduce the organic hazardous air pollutant... non-diverting position with a car-seal or a lock-and-key type configuration. A visual inspection of...
40 CFR 63.1413 - Compliance demonstration procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... liquids, other than fuels, received by the control device. (i) For a scrubber, the design evaluation shall... scrubbing liquid. The design evaluation shall establish the design exhaust vent stream organic compound... process vent and the overall percent reduction for the collection of non-reactor batch process vents...
System for venting gas from a liquid storage tank
NASA Astrophysics Data System (ADS)
Dugan, Regina E.
1989-07-01
Gas is vented from a non-cryogenic liquid storage tank while discharging pressurized liquid from a tube into the tank through a plurality of inclined jets, circumferentially spaced about an end of a vent tube positioned within the tube. Each jet is directed toward a central axis of the vent tube, such that the end of the vent tube receives gas from the vessel passing between individual jetstreams, which in combination form a conical shaped barrier to liquid droplets which would otherwise also pass to the vent tube and out the tank. Gas is thus vented through the central tube while pressurized liquid flows in an axially opposite direction in the annulus between the inner vent tube and the outer liquid tube. The system of the present invention is prarticularly well suited for venting gas from a tank being replenished with liquid at a zero or near zero gravity environment. A screen-type liquid acquisition device employing surface tension is provided for withdrawing substantially liquid from the tank. The withdrawn liquid may be resupplied to the liquid tube under pressure supplied by a circulating pump, thereby releasing substantially only gas from the storage tank to reduce the pressure in the tank.
40 CFR 65.164 - Performance test and flare compliance determination notifications and reports.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.164 Performance test and flare... complete test report shall include a brief process description, sampling site description, description of...
NASA Astrophysics Data System (ADS)
Lundgren, J.; Esham, B.; Padalino, S. J.; Sangster, T. C.; Glebov, V.
2007-11-01
The Venting and Exhausting of Low Level Air Contaminants in the Rapid Pneumatic Transport of Radioactive Samples (VELoCiRaPTORS) system is constructed to transport radioactive materials quickly and safely at the NIF. A radioactive sample will be placed inside a carrier that is transported via an airflow system produced by controlled differential pressure. Midway through the transportation process, the carrier will be stopped and vented by a powered exhaust blower which will remove radioactive gases within the transport carrier. A Geiger counter will monitor the activity of the exhaust gas to ensure that it is below acceptable levels. If the radiation level is sufficient, the carrier will pass through the remainder of the system, pneumatically braking at the counting station. The complete design will run manually or automatically with control software. Tests were performed using an inactive carrier to determine possible transportation problems. The system underwent many consecutive trials without failure. VELoCiRaPTORS is a prototype of a system that could be installed at both the Laboratory for Laser Energetics at the University of Rochester and the National Ignition Facility at LLNL.
NASA Astrophysics Data System (ADS)
Allen, Douglas E.; Seyfried, W. E.
2005-02-01
A hydrothermal experiment involving peridotite and a coexisting aqueous fluid was conducted to assess the role of dissolved Cl - and redox on REE mobility at 400°C, 500 bars. Data show that the onset of reducing conditions enhances the stability of soluble Eu +2 species. Moreover, Eu +2 forms strong aqueous complexes with dissolved Cl - at virtually all redox conditions. Thus, high Cl - concentrations and reducing conditions can combine to reinforce Eu mobility. Except for La, trivalent REE are not greatly affected by fluid speciation under the chemical and physical condition considered, suggesting control by secondary mineral-fluid partitioning. LREE enrichment and positive Eu anomalies observed in fluids from the experiment are remarkably similar to patterns of REE mobility in vent fluids issuing from basalt- and peridotite-hosted hydrothermal systems. This suggests that the chondrite normalized REE patterns are influenced greatly by fluid speciation effects and secondary mineral formation processes. Accordingly, caution must be exercised when using REE in hydrothermal vent fluids to infer REE sources in subseafloor reaction zones from which the fluids are derived. Although vent fluid patterns having LREE enrichment and positive Eu anomalies are typically interpreted to suggest plagioclase recrystallization reactions, this need not always be the case.
Zero-G Thermodynamic Venting System (TVS) Performance Prediction Program
NASA Technical Reports Server (NTRS)
Nguyen, Han
1994-01-01
This report documents the Zero-g Thermodynamic Venting System (TVS) performance prediction computer program. The zero-g TVS is a device that destratifies and rejects environmentally induced zero-g thermal gradients in the LH2 storage transfer system. A recirculation pump and spray injection manifold recirculates liquid throughout the length of the tank thereby destratifying both the ullage gas and liquid bulk. Heat rejection is accomplished by the opening of the TVS control valve which allows a small flow rate to expand to a low pressure thereby producing a low temperature heat sink which is used to absorb heat from the recirculating liquid flow. The program was written in FORTRAN 77 language on the HP-9000 and IBM PC computers. It can be run on various platforms with a FORTRAN compiler.
Constant pressure high throughput membrane permeation testing system
Albenze, Erik J.; Hopkinson, David P.; Luebke, David R.
2014-09-02
The disclosure relates to a membrane testing system for individual evaluation of a plurality of planar membranes subjected to a feed gas on one side and a sweep gas on a second side. The membrane testing system provides a pressurized flow of a feed and sweep gas to each membrane testing cell in a plurality of membrane testing cells while a stream of retentate gas from each membrane testing cell is ported by a retentate multiport valve for sampling or venting, and a stream of permeate gas from each membrane testing cell is ported by a permeate multiport valve for sampling or venting. Back pressure regulators and mass flow controllers act to maintain substantially equivalent gas pressures and flow rates on each side of the planar membrane throughout a sampling cycle. A digital controller may be utilized to position the retentate and permeate multiport valves cyclically, allowing for gas sampling of different membrane cells over an extended period of time.
40 CFR 63.1332 - Emissions averaging provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... other controls for a Group 1 storage vessel, batch process vent, aggregate batch vent stream, continuous... in control after November 15, 1990. (2) Group 1 emission points, identified in paragraph (c)(3) of... applicable reference control technology or standard and the emissions allowed for the Group 1 emission point...
40 CFR 63.487 - Batch front-end process vents-reference control technology.
Code of Federal Regulations, 2011 CFR
2011-07-01
... control technology. 63.487 Section 63.487 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.487 Batch front-end process vents—reference control technology. (a) Batch front-end process vents...
40 CFR 63.1332 - Emissions averaging provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... other controls for a Group 1 storage vessel, batch process vent, aggregate batch vent stream, continuous... in control after November 15, 1990. (2) Group 1 emission points, identified in paragraph (c)(3) of... reference control technology or standard and the emissions allowed for the Group 1 emission point. Said...
40 CFR 63.1275 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Glycol dehydration unit process vent... Storage Facilities § 63.1275 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as...
40 CFR 63.1275 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Glycol dehydration unit process vent... Storage Facilities § 63.1275 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as...
40 CFR 63.653 - Monitoring, recordkeeping, and implementation plan for emissions averaging.
Code of Federal Regulations, 2011 CFR
2011-07-01
... § 63.120 of subpart G; and (ii) For closed vent systems with control devices, conduct an initial design... different times, and/or in different submittals, later submittals may refer to earlier submittals instead of... controlled using a treatment process or series of treatment processes that achieves an emission reduction...
30 CFR 250.433 - What are the diverter actuation and testing requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
... OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations...-control systems and control stations. You must also flow-test the vent lines. (a) For drilling operations... must conduct subsequent pressure tests within 7 days after the previous test. (b) For floating drilling...
Mixing-induced fluid destratification and ullage condensation
NASA Technical Reports Server (NTRS)
Meserole, Jere S.; Jones, Ogden S.; Fortini, Anthony F.
1987-01-01
In many applications, on-orbit storage and transfer of cryogens will require forced mixing to control tank pressure without direct venting to space. During a no-vent transfer or during operation of a thermodynamic vent system in a cryogen storage tank, pressure control is achieved by circulating cool liquid to the liquid-vapor interface to condense some of the ullage vapor. To measure the pressure and temperature response rates in mixing-induced condensation, an experiment has been developed using Freon 11 to simulate the two-phase behavior of a cryogen. A thin layer at the liquid surface is heated to raise the tank pressure, and then a jet mixer is turned on to circulate the liquid, cool the surface, and reduce the pressure. Many nozzle configurations and flow rates are used. Tank pressure and the temperature profiles in the ullage and the liquid are measured. Initial data from this ground test are shown correlated with normal-gravity and drop-tower dye-mixing data. Pressure collapse times are comparable to the dye-mixing times, whereas the times needed for complete thermal mixing are much longer than the dye-mixing times.
Code of Federal Regulations, 2013 CFR
2013-07-01
... performance test for those control techniques in accordance with paragraph (b)(6) of this section. The design..., immediately preceding the use of the control technique. A design evaluation shall also address other vent... paragraph (f)(1)(i) of this section, the design evaluation shall document the control efficiency and address...
40 CFR 265.1033 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... carbon adsorption system such as a fixed-bed carbon adsorber that regenerates the carbon bed directly in... using a carbon adsorption system such as a fixed-bed carbon adsorber that regenerates the carbon bed... established as a requirement of § 265.1035(b)(4)(iii)(F). (h) An owner or operator using a carbon adsorption...
40 CFR 270.310 - What equipment information must I keep at my facility?
Code of Federal Regulations, 2011 CFR
2011-07-01
... mechanical seals). (b) For facilities that cannot install a closed-vent system and control device to comply... Gaseous Emissions” (incorporated by reference as specified in 40 CFR 260.11) or other engineering texts...
40 CFR 61.349 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... closed position with a car-seal or a lock-and-key type configuration, a flow indicator is not required... with the following conditions: (i) An enclosed combustion device (e.g., a vapor incinerator, boiler, or...
40 CFR 60.482-2a - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... routed to a process or fuel gas system or connected by a closed vent system to a control device that... sensor that will detect failure of the seal system, the barrier fluid system, or both. (4)(i) Each pump... indications of liquids dripping as a leak. (5)(i) Each sensor as described in paragraph (d)(3) is checked...
46 CFR 153.350 - Location of B/3 vent discharges.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Location of B/3 vent discharges. 153.350 Section 153.350 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS... Venting Systems § 153.350 Location of B/3 vent discharges. Except as prescribed in § 153.353, a B/3...
46 CFR 56.50-85 - Tank-vent piping.
Code of Federal Regulations, 2010 CFR
2010-10-01
... of the tanks to vent pipes. (2) Tanks having a comparatively small surface, such as fuel oil settling... 46 Shipping 2 2010-10-01 2010-10-01 false Tank-vent piping. 56.50-85 Section 56.50-85 Shipping... APPURTENANCES Design Requirements Pertaining to Specific Systems § 56.50-85 Tank-vent piping. (a) This section...
NASA Astrophysics Data System (ADS)
Majumdar, Alok; Valenzuela, Juan; LeClair, Andre; Moder, Jeff
2016-03-01
This paper presents a numerical model of a system-level test bed-the multipurpose hydrogen test bed (MHTB) using the Generalized Fluid System Simulation Program (GFSSP). MHTB is representative in size and shape of a space transportation vehicle liquid hydrogen propellant tank, and ground-based testing was performed at NASA Marshall Space Flight Center (MSFC) to generate data for cryogenic storage. GFSSP is a finite volume-based network flow analysis software developed at MSFC and used for thermofluid analysis of propulsion systems. GFSSP has been used to model the self-pressurization and ullage pressure control by the Thermodynamic Vent System (TVS). A TVS typically includes a Joule-Thompson (J-T) expansion device, a two-phase heat exchanger (HEX), and a mixing pump and liquid injector to extract thermal energy from the tank without significant loss of liquid propellant. For the MHTB tank, the HEX and liquid injector are combined into a vertical spray bar assembly. Two GFSSP models (Self-Pressurization and TVS) were separately developed and tested and then integrated to simulate the entire system. The Self-Pressurization model consists of multiple ullage nodes, a propellant node, and solid nodes; it computes the heat transfer through multilayer insulation blankets and calculates heat and mass transfer between the ullage and liquid propellant and the ullage and tank wall. A TVS model calculates the flow through a J-T valve, HEX, and spray and vent systems. Two models are integrated by exchanging data through User Subroutines of both models. Results of the integrated models have been compared with MHTB test data at a 50% fill level. Satisfactory comparison was observed between tests and numerical predictions.
Airflow Measurement of the Car HVAC Unit Using Hot-wire Anemometry
NASA Astrophysics Data System (ADS)
Fojtlín, Miloš; Planka, Michal; Fišer, Jan; Pokorný, Jan; Jícha, Miroslav
2016-03-01
Thermal environment in a vehicular cabin significantly influence drivers' fatigue and passengers' thermal comfort. This environment is traditionally managed by HVAC cabin system that distributes air and modifies its properties. In order to simulate cabin thermal behaviour, amount of the air led through car vents must be determined. The aim of this study was to develop methodology to measure airflow from the vents, and consequently calculate corresponding air distribution coefficients. Three climatic cases were selected to match European winter, summer, and spring / fall conditions. Experiments were conducted on a test vehicle in a climatic chamber. The car HVAC system was set to automatic control mode, and the measurements were executed after the system stabilisation—each case was independently measured three times. To be able to evaluate precision of the method, the airflow was determined at the system inlet (HVAC suction) and outlet (each vent), and the total airflow values were compared. The airflow was calculated by determining a mean value of the air velocity multiplied by an area of inlet / outlet cross-section. Hot-wire anemometry was involved to measure the air velocity. Regarding the summer case, total airflow entering the cabin was around 57 l s-1 with 60 % of the air entering the cabin through dashboard vents; no air was supplied to the feet compartment. The remaining cases had the same total airflow of around 42 l s-1, and the air distribution was focused mainly on feet and windows. The inlet and outlet airflow values show a good match with a maximum mass differential of 8.3 %.
Space Evaporator Absorber Radiator (SEAR) for Thermal Storage on Manned Spacecraft
NASA Technical Reports Server (NTRS)
Izenson, Michael G.; Chen, Weibo; Chepko, Ariane; Bue, Grant; Quinn, Gregory
2014-01-01
Future manned exploration spacecraft will need to operate in challenging thermal environments. State-of the- art technology for active thermal control relies on sublimating water ice and venting the vapor overboard in very hot environments. This approach can lead to large loss of water and a significant mass penalty for the spacecraft. This paper describes an innovative thermal control system that uses a Space Evaporator Absorber Radiator (SEAR) to control spacecraft temperatures in highly variable environments without venting water. SEAR uses heat pumping and energy storage by LiCl/water absorption to enable effective cooling during hot periods and regeneration during cool periods. The LiCl absorber technology has the potential to absorb over 800 kJ per kg of system mass, compared to phase change heat sink systems that typically achieve approx. 50 kJ/kg. The optimal system is based on a trade-off between the mass of water saved and extra power needed to regenerate the LiCl absorber. This paper describes analysis models and the predicted performance and optimize the size of the SEAR system, estimated size and mass of key components, and power requirements for regeneration. We also present a concept design for an ISS test package to demonstrate operation of a subscale system in zero gravity.
40 CFR 63.765 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Glycol dehydration unit process vent... Facilities § 63.765 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as specified in either...
40 CFR 63.765 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Glycol dehydration unit process vent... Facilities § 63.765 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as specified in either...
40 CFR 63.2455 - What requirements must I meet for continuous process vents?
Code of Federal Regulations, 2011 CFR
2011-07-01
... CATEGORIES National Emission Standards for Hazardous Air Pollutants: Miscellaneous Organic Chemical... any continuous process vent that is combined with Group 1 batch process vents before a control device or recovery device because the requirements of § 63.2450(c)(2)(i) apply to the combined stream. (2...
VOC Emission Reduction Study at the Hill Air Force Base Building 515 Painting Facility
1990-09-01
occurs during painting. A system for decreasing the flow to a downstream VOC emission control device can be designed that takes advantage of this...paint application process. A flow-reducing ventilation system that takes advantage of this operating characteristic can be designed in which the...flow from the second duct is vented to a VOC emission control device. The advantage of this system is that the flow rate to a VOC emission contro
2001-08-08
KENNEDY SPACE CENTER, Fla. -- Floodlights reveal the Space Shuttle Discovery after rollback of the Rotating Service Structure in preparation for launch on mission STS-105. Above the external tank, the “beanie cap” is poised, waiting for loading of the propellants. The cap, or vent hood, is on the end of the gaseous oxygen vent arm that allows gaseous oxygen vapors to vent away from the Space Shuttle. On the mission, Discovery will be transporting the Expedition Three crew and several payloads and scientific experiments to the ISS, including the Early Ammonia Servicer (EAS) tank. The EAS, which will support the thermal control subsystems until a permanent system is activated, will be attached to the Station during two spacewalks. The three-member Expedition Two crew will be returning to Earth aboard Discovery after a five-month stay on the Station. Launch is scheduled for 5:38 p.m. EDT Aug. 9
Assessment of Literature Related to Combustion Appliance Venting Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rapp, V. H.; Less, B. D.; Singer, B. C.
In many residential building retrofit programs, air tightening to increase energy efficiency is often constrained by safety concerns with naturally vented combustion appliances. Tighter residential buildings more readily depressurize when exhaust equipment is operated, making combustion appliances more prone to backdraft or spill combustion exhaust into the living space. Several measures, such as installation guidelines, vent sizing codes, and combustion safety diagnostics, are in place with the intent to prevent backdrafting and combustion spillage, but the diagnostics conflict and the risk mitigation objective is inconsistent. This literature review summarizes the metrics and diagnostics used to assess combustion safety, documents theirmore » technical basis, and investigates their risk mitigations. It compiles information from the following: codes for combustion appliance venting and installation; standards and guidelines for combustion safety diagnostics; research evaluating combustion safety diagnostics; research investigating wind effects on building depressurization and venting; and software for simulating vent system performance.« less
40 CFR 63.11395 - What are the standards and compliance requirements for existing sources?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Modacrylic Fibers Production Area Sources Standards and Compliance Requirements § 63.11395 What are the... enclosure systems that collect the gases and fumes containing acrylonitrile (AN) released from... through a closed vent system to a control device. (b) Except as provided in paragraph (b)(3) of this...
40 CFR 63.11395 - What are the standards and compliance requirements for existing sources?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Modacrylic Fibers Production Area Sources Standards and Compliance Requirements § 63.11395 What are the... enclosure systems that collect the gases and fumes containing acrylonitrile (AN) released from... through a closed vent system to a control device. (b) Except as provided in paragraph (b)(3) of this...
NASA Astrophysics Data System (ADS)
McDermott, Jill M.; Sylva, Sean P.; Ono, Shuhei; German, Christopher R.; Seewald, Jeffrey S.
2018-05-01
Hosted in basaltic substrate on the ultra-slow spreading Mid-Cayman Rise, the Piccard hydrothermal field is the deepest currently known seafloor hot-spring (4957-4987 m). Due to its great depth, the Piccard site is an excellent natural system for investigating the influence of extreme pressure on the formation of submarine vent fluids. To investigate the role of rock composition and deep circulation conditions on fluid chemistry, the abundance and isotopic composition of organic, inorganic, and dissolved volatile species in high temperature vent fluids at Piccard were examined in samples collected in 2012 and 2013. Fluids from the Beebe Vents and Beebe Woods black smokers vent at a maximum temperature of 398 °C at the seafloor, however several lines of evidence derived from inorganic chemistry (Cl, SiO2, Ca, Br, Fe, Cu, Mn) support fluid formation at much higher temperatures in the subsurface. These high temperatures, potentially in excess of 500 °C, are attainable due to the great depth of the system. Our data indicate that a single deep-rooted source fluid feeds high temperature vents across the entire Piccard field. High temperature Piccard fluid H2 abundances (19.9 mM) are even higher than those observed in many ultramafic-influenced systems, such as the Rainbow (16 mM) and the Von Damm hydrothermal fields (18.2 mM). In the case of Piccard, however, these extremely high H2 abundances can be generated from fluid-basalt reaction occurring at very high temperatures. Magmatic and thermogenic sources of carbon in the high temperature black smoker vents are described. Dissolved ΣCO2 is likely of magmatic origin, CH4 may originate from a combination of thermogenic sources and leaching of abiotic CH4 from mineral-hosted fluid inclusions, and CO abundances are at equilibrium with the water-gas shift reaction. Longer-chained n-alkanes (C2H6, C3H8, n-C4H10, i-C4H10) may derive from thermal alteration of dissolved and particulate organic carbon sourced from the original seawater source, entrainment of microbial ecosystems peripheral to high temperature venting, and/or abiotic mantle sources. Dissolved ΣHCOOH in the Beebe Woods fluid is consistent with thermodynamic equilibrium for abiotic production via ΣCO2 reduction with H2 at 354 °C measured temperature. A lack of ΣHCOOH in the relatively higher temperature 398 °C Beebe Vent fluids demonstrates the temperature sensitivity of this equilibrium. Abundant basaltic seafloor outcrops and the axial location of the vent field, along with multiple lines of geochemical evidence, support extremely high temperature fluid-rock reaction with mafic substrate as the dominant control on Piccard fluid chemistry. These results expand the known diversity of vent fluid composition, with implications for supporting microbiological life in both the modern and ancient ocean.
Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-Humid Climates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueno, Kohta; Lstiburek, Joseph W.
2015-09-01
Insulating roofs with dense-pack cellulose (instead of spray foam) has moisture risks, but is a lower cost approach. If moisture risks could be addressed, buildings could benefit from retrofit options, and the ability to bring HVAC systems within the conditioned space. Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a control vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except themore » vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a diffusion vent detail, capped with vapor permeable roof membrane. Some ridge sections were built as a conventional unvented roof, as a control. In the control unvented roofs, roof peak RHs reached high levels in the first winter; as exterior conditions warmed, RHs quickly fell. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
2015-09-01
Insulating roofs with dense-pack cellulose (instead of spray foam) has moisture risks, but is a lower cost approach. If moisture risks could be addressed, buildings could benefit from retrofit options, and the ability to bring HVAC systems within the conditioned space. Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a 'control' vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except themore » vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a 'diffusion vent' detail, capped with vapor permeable roof membrane. Some ridge sections were built as a conventional unvented roof, as a control. In the control unvented roofs, roof peak RHs reached high levels in the first winter; as exterior conditions warmed, RHs quickly fell. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).« less
Design and integrated operation of an innovative thermodynamic vent system concept
NASA Astrophysics Data System (ADS)
Fazah, Michel M.; Lak, Tibor; Nguyen, Han; Wood, Charles C.
1993-06-01
A unique zero-g thermodynamic vent system (TVS) is being developed by NASA's Marshall Space Flight Center (MSFC) and Rockwell International to meet cryogenic propellant management requirements for future space missions. The design is highly innovative in that it integrates the functions of a spray-bar tank mixer and a TVS. This concept not only satisfies the requirement for efficient tank mixing and zero-g venting but also accommodates thermal conditioning requirements for other components (e.g., engine feed lines, turbopumps, and liquid acquisition devices). In addition, operations can be extended to accomplish tank chill-down, no-vent fill, and emergency venting during zero-g propellant transfer. This paper describes the system performance characterization and future test activities that are part of MSFC's Multipurpose Hydrogen Test Bed (MHTB) program. The testing will demonstrate the feasibility and merit of the design, and serve as a proof-of-concept development activity.
NASA Technical Reports Server (NTRS)
Saiidi, M. J.; Duffy, R. E.; Mclaughlin, T. D.
1986-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis/Critical Items List (FMEA/CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results corresponding to the Orbiter Atmospheric Revitalization and Pressure Control Subsystem (ARPCS) are documented. The ARPCS hardware was categorized into the following subdivisions: (1) Atmospheric Make-up and Control (including the Auxiliary Oxygen Assembly, Oxygen Assembly, and Nitrogen Assembly); and (2) Atmospheric Vent and Control (including the Positive Relief Vent Assembly, Negative Relief Vent Assembly, and Cabin Vent Assembly). The IOA analysis process utilized available ARPCS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-11
... tests will help to ensure that control systems are maintained properly over time and a more rigorous... approach, industry is expected to save time in the performance test submittal process. Additionally this... pulping vent gas control at mills where the CCA approach would be adversely affected. Our revised cost...
Space Evaporator Absorber Radiator (SEAR) for Thermal Storage on Manned Spacecraft
NASA Technical Reports Server (NTRS)
Izenson, Michael G.; Chen, Weibo; Chepko, Ariane; Bue, Grant; Quinn, Gregory
2015-01-01
Future manned exploration spacecraft will need to operate in challenging thermal environments. State-of-the-art technology for active thermal control relies on sublimating water ice and venting the vapor overboard in very hot environments, and or heavy phase change material heat exchangers for thermal storage. These approaches can lead to large loss of water and a significant mass penalties for the spacecraft. This paper describes an innovative thermal control system that uses a Space Evaporator Absorber Radiator (SEAR) to control spacecraft temperatures in highly variable environments without venting water. SEAR uses heat pumping and energy storage by LiCl/water absorption to enable effective cooling during hot periods and regeneration during cool periods. The LiCl absorber technology has the potential to absorb over 800 kJ per kg of system mass, compared to phase change heat sink systems that typically achieve approx. 50 kJ/kg. This paper describes analysis models to predict performance and optimize the size of the SEAR system, estimated size and mass of key components, and an assessment of potential mass savings compared with alternative thermal management approaches. We also describe a concept design for an ISS test package to demonstrate operation of a subscale system in zero gravity.
Gas hydrate and spatial venting variations in the continental margin offshore Southwestern Taiwan
NASA Astrophysics Data System (ADS)
Lin, S.; Lim, Y.; Hsieh, W.; Yang, T.; Wang, Y.
2006-12-01
Strong BSR, high methane contents and rapid sulfate reduction were found in the continental margin sediments offshore southwestern Taiwan. In order to identify the venting phenomena and its relationship with gas hydrate, this research investigate sea floor vent features using WHOI?|s Towcam system as well as piston core in the study region. A total of 10 dives were conducted on board the r/v OR-1. Pore water sulfate, dissolved sulfide, methane, chloride, del O18 ratio, sediment organic carbon, carbonate content and carbonate del C13 ratio, pyrite-S were measured Large spatial variations were found based on pictures obtained from Towcam system and piston cores. Active venting features include bacteria mat, live dense bivalve patches, gas plume, temperature and salinity fluctuations, rapid sulfate reduction and high concentrations of methane in sediments. In addition, vent chimney, pockmark and large authigenic carbonate buildup were also observed in the active venting area. In contrast, in some areas without active venting features, scatter dead chimney, semi- buried carbonate structures, and dead bivalves were found. Total sulfate depletion was found at depth as shallow as 1 meter below sediment water interface in area near active vent whereas almost no sulfate depletion was observed in areas without any vent feature. Stages of carbonate build up existed, with initial phase dominated by small tube, chimney, and later with massive carbonate structures protruding the sea floor. The appearances of massive carbonate buildup structures seemed to indicate the end stage of gas hydrate venting phenomena.
New Episodes of Volcanism at Kilauea Volcano, Hawaii
NASA Astrophysics Data System (ADS)
Poland, Michael; Miklius, Asta; Orr, Tim; Sutton, Jeff; Thornber, Carl; Wilson, David
2008-01-01
Mid-2007 was a time of intense activity at Kilauea Volcano, Hawaii (see Figure 1). In June, the long-lived Pu`u `Ō`ō-Kupaianaha eruption, a dual-vent system along the east rift zone (ERZ) that has been erupting since 1983 [Heliker et al., 2003], paused due to the outbreak of a new vent farther up the rift (see Figure 2). The Pu`u `Ō`ō vent collapsed following that activity, and the resulting reorganization of the magma plumbing system led to the formation of a second new eruptive vent 2 kilometers downrift of Pu`u `Ō`ō.
Hydrogen Vent Ground Umbilical Quick Disconnect - Flight Seal Advanced Development
NASA Technical Reports Server (NTRS)
Girard, Doug; Jankowski, Fred; Minich, Mark C.; Yu, Weiping
2012-01-01
This project is a team effort between NASA Engineering (NE) and Team QNA Engineering personnel to provide support for the Umbilical Systems Development project which is funded by Advanced Exploration Systems (AES) and 21st Century Launch Complex. Specifically, this project seeks to develop a new interface between the PPBE baselined Legacy SSP LH2 Vent Arm QD probe and SLS vent seal.
NASA Astrophysics Data System (ADS)
Crone, T. J.; Kinsey, J. C.; Mittelstaedt, E. L.
2017-12-01
Hydrothermal venting at mid-ocean ridges influences ocean chemistry, the thermal and chemical structure of the oceanic crust, and the evolution of unique and diverse autolithotrophically-supported ecosystems. Axially-hosted hydrothermal systems are responsible for 20-25% of the total heat flux out of Earth's interior, and likely play a large role in local as well as global biogeochemical cycles. Despite the importance of these systems, only a few studies have attempted to constrain the volume and heat flux of an entire hydrothermal vent field. In July of 2014 we used the Sentry autonomous underwater vehicle (AUV) to survey the water column over the ASHES hydrothermal vent field which is located within the caldera of Axial Seamount, an active submarine volcano located on the Juan de Fuca Ridge. To estimate the total heat and mass flux from this vent field, we equipped Sentry with a Nortek acoustic Doppler velocimeter (ADV), an inertial measurement unit (IMU), two acoustic Doppler current profilers (ADCPs), and two SBE3 temperature probes, allowing us to obtain precise measurements of fluid temperature and water velocity. The survey was designed using a control volume approach in which Sentry was pre-programmed to survey a 150-m-square centered over the vent field flying a grid pattern with 5-m track line spacing followed by a survey of the perimeter. This pattern was repeated multiple times during several 10-h dives at different altitudes, including 10, 20, 40, and 60 m above the seafloor, and during one 40-h survey at an altitude of 10 m. During the 40-h survey, the pattern was repeated nine times allowing us to obtain observations over several tidal cycles. Water velocity data obtained with Sentry were corrected for platform motion and then combined with the temperature measurements to estimate heat flux. The analysis of these data will likely provide the most accurate and highest resolution heat and mass flux estimates at a seafloor hydrothermal field to date.
NASA Technical Reports Server (NTRS)
Glaze, Lori S.; Baloga, Stephen M.; Wimert, Jesse
2010-01-01
Conditions required to support buoyant convective plumes are investigated for explosive volcanic eruptions from circular and linear vents on Earth, Venus, and Mars. Vent geometry (linear versus circular) plays a significant role in the ability of an explosive eruption to sustain a buoyant plume. On Earth, linear and circular vent eruptions are both capable of driving buoyant plumes to equivalent maximum rise heights, however, linear vent plumes are more sensitive to vent size. For analogous mass eruption rates, linear vent plumes surpass circular vent plumes in entrainment efficiency approximately when L(sub o) > 3r(sub o) owing to the larger entrainment area relative to the control volume. Relative to circular vents, linear vents on Venus favor column collapse and the formation of pyroclastic flows because the range of conditions required to establish and sustain buoyancy is narrow. When buoyancy can be sustained, however, maximum plume heights exceed those from circular vents. For current atmospheric conditions on Mars, linear vent eruptions are capable of injecting volcanic material slightly higher than analogous circular vent eruptions. However, both geometries are more likely to produce pyroclastic fountains, as opposed to convective plumes, owing to the low density atmosphere. Due to the atmospheric density profile and water content on Earth, explosive eruptions enjoy favorable conditions for producing sustained buoyant columns, while pyroclastic flows would be relatively more prevalent on Venus and Mars. These results have implications for the injection and dispersal of particulates into the planetary atmosphere and the ability to interpret the geologic record of planetary volcanism.
Mesoscale Laboratory Models of the Biodegradation of Municipal Landfill Materials
NASA Astrophysics Data System (ADS)
Borglin, S. E.; Hazen, T. C.; Oldenburg, C. M.; Zawislanski, P. T.
2001-12-01
Stabilization of municipal landfills is a critical issue involving land reuse, leachate treatment, and odor control. In an effort to increase landfill stabilization rates and decrease leachate treatment costs, municipal landfills can be operated as active aerobic or anaerobic bioreactors. Rates of settling and biodegradation were compared in three different treatments of municipal landfill materials in laboratory-scale bioreactors. Each of the three fifty-five-gallon clear acrylic tanks was fitted with pressure transducers, thermistors, neutron probe access tubes, a leachate recirculation system, gas vents, and air injection ports. The treatments applied to the tanks were (a) aerobic (air injection with leachate recirculation and venting from the top), (b) anaerobic (leachate recirculation with passive venting from the top), and (c) a control tank (passive venting from the top and no leachate recirculation). All tanks contained a 10-cm-thick layer of pea gravel at the bottom, overlain by a mixture of fresh waste materials on the order of 5-10 cm in size to an initial height of 0.55 m. Concentrations of O2, CO2 and CH4 were measured at the gas vent, and leachate was collected at the bottom drain. The water saturation in the aerobic and anaerobic tanks averaged 17 % and the control tank averaged 1 %. Relative degradation rates between the tanks were monitored by CO2 and CH4 production rates and O2 respiration rates. Respiration tests on the aerobic tank show a decrease in oxygen consumption rates from 1.3 mol/day at 20 days to 0.1 mol/day at 300 days, indicating usable organics are being depleted. The anaerobic tank produced measurable methane after 300 days that increased to 41% by volume after 370 days. Over the test period, the aerobic tank settled 30 %, the anaerobic tank 18.5 %, and the control tank 11.1 %. The concentrations of metals, nitrate, phosphate, and total organic carbon in the aerobic tank leachate are an order of magnitude lower than in the anaerobic tank leachate. This work was supported by Laboratory Directed Research and Development Funds at Lawrence Berkeley National Laboratory under Department of Energy Contract No. DE-AC03-76SF00098.
NASA Technical Reports Server (NTRS)
1961-01-01
The nature of the potential fuel tank vent fire and explosion hazard is discussed in relation to present vent exit design practice, available knowledge of atmospheric electricity as a source of ignition energy, and the vent system vapor space environment. Flammable mixtures and possible ignition sources may occur simultaneously as a rare phenomena according to existing knowledge. There is a need to extend the state of science in order to make possible vent design which is aimed specifically at minimizing fire and explosion hazards.
75 FR 65032 - Notice of Lodging of Consent Decree
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-21
... absorber vent as a Group 2 process vent under the Hazardous Organic NESHAP regulations. For three years, Westlake will also implement an enhanced Leak Detection and Repair program to control emissions of...'s common control, and Westlake will not contest administratively or judicially a finding by the...
NASA Technical Reports Server (NTRS)
Minor, Robert
2002-01-01
Two ISS (International Space Station) experiment payloads will vent a volume of gas overboard via either the ISS Vacuum Exhaust System or the Vacuum Resource System. A system of ducts, valves and sensors, under design, will connect the experiments to the ISS systems. The following tasks are required: Create an analysis tool that will verify the rack vacuum system design with respect to design requirements, more specifically approximate pressure at given locations within the vacuum systems; Determine the vent duration required to achieve desired pressure within the experiment modules; Update the analysis as systems and operations definitions mature.
Comparison of the compressive strength of 3 different implant design systems.
Pedroza, Jose E; Torrealba, Ysidora; Elias, Augusto; Psoter, Walter
2007-01-01
The aims of this study were twofold: to compare the static compressive strength at the implant-abutment interface of 3 design systems and to describe the implant abutment connection failure mode. A stainless steel holding device was designed to align the implants at 30 degrees with respect to the y-axis. Sixty-nine specimens were used, 23 for each system. A computer-controlled universal testing machine (MTS 810) applied static compression loading by a unidirectional vertical piston until failure. Specimens were evaluated macroscopically for longitudinal displacement, abutment looseness, and screw and implant fracture. Data were analyzed by analysis of variance (ANOVA). The mean compressive strength for the Unipost system was 392.5 psi (SD +/-40.9), for the Spline system 342.8 psi (SD+/-25.8), and for the Screw-Vent system 269.1 psi (SD+/-30.7). The Unipost implant-abutment connection demonstrated a statistically significant superior mechanical stability (P < or = .009) compared with the Spline implant system. The Spline implant system showed a statistically significant higher compressive strength than the Screw-Vent implant system (P < or =.009). Regarding failure mode, the Unipost system consistently broke at the same site, while the other systems failed at different points of the connection. The Unipost system demonstrated excellent fracture resistance to compressive forces; this resistance may be attributed primarily to the diameter of the abutment screw and the 2.5 mm counter bore, representing the same and a unique piece of the implant. The Unipost implant system demonstrated a statistically significant superior compressive strength value compared with the Spline and Screw-Vent systems, at a 30 degrees angulation.
Reveillaud, Julie; Reddington, Emily; McDermott, Jill; Algar, Christopher; Meyer, Julie L.; Sylva, Sean; Seewald, Jeffrey; German, Christopher R.
2016-01-01
Summary Warm fluids emanating from hydrothermal vents can be used as windows into the rocky subseafloor habitat and its resident microbial community. Two new vent systems on the Mid‐Cayman Rise each exhibits novel geologic settings and distinctively hydrogen‐rich vent fluid compositions. We have determined and compared the chemistry, potential energy yielding reactions, abundance, community composition, diversity, and function of microbes in venting fluids from both sites: Piccard, the world's deepest vent site, hosted in mafic rocks; and Von Damm, an adjacent, ultramafic‐influenced system. Von Damm hosted a wider diversity of lineages and metabolisms in comparison to Piccard, consistent with thermodynamic models that predict more numerous energy sources at ultramafic systems. There was little overlap in the phylotypes found at each site, although similar and dominant hydrogen‐utilizing genera were present at both. Despite the differences in community structure, depth, geology, and fluid chemistry, energetic modelling and metagenomic analysis indicate near functional equivalence between Von Damm and Piccard, likely driven by the high hydrogen concentrations and elevated temperatures at both sites. Results are compared with hydrothermal sites worldwide to provide a global perspective on the distinctiveness of these newly discovered sites and the interplay among rocks, fluid composition and life in the subseafloor. PMID:26663423
On the early fate of hydrothermal iron at deep-sea vents: A reassessment after in situ filtration
NASA Astrophysics Data System (ADS)
Waeles, M.; Cotte, L.; Pernet-Coudrier, B.; Chavagnac, V.; Cathalot, C.; Leleu, T.; Laës-Huon, A.; Perhirin, A.; Riso, R. D.; Sarradin, P.-M.
2017-05-01
Deep-sea hydrothermal venting is now recognized as a major source of iron (Fe), an essential trace element that controls marine productivity. However, the reactions occurring during dispersal from buoyant plumes to neutrally buoyant hydrothermal plumes are still poorly constrained. Here we report for the first time on the dissolved-particulate partition of Fe after in situ filtration at the early stage of mixing at different hydrothermal discharges, i.e., Lucky Strike (37°N), TAG (26°N), and Snakepit (23°N) on the Mid-Atlantic Ridge. We found that hydrothermal iron is almost completely preserved (>90%) in the dissolved fraction, arguing for low iron-bearing sulfide precipitation of iron in basalt-hosted systems with low Fe:H2S ratios. This result can only be explained by a kinetically limited formation of pyrite. The small part of Fe being precipitated as sulfides in the mixing gradient (<10%) is restricted to the inclusion of Fe in minerals of high Cu and Zn content. We also show that secondary venting is a source of Fe-depleted hydrothermal solutions. These results provide new constrains on Fe fluxes from hydrothermal venting.
NASA Technical Reports Server (NTRS)
Ungar, Eugene K.; Erickson, Lisa R.
2011-01-01
A planned use of the Orion space vehicle involves its residence at the International Space Station for six months at a time. One concept of operations involves temporarily venting portions of the idle Orion active thermal control system (ATCS) during the docked phase, preventing freezing. The venting would have to be reasonably complete with few, if any, completely filled pockets of frozen liquid. Even if pockets of frozen liquid did not damage the hardware during the freezing process, they could prevent the system from filling completely prior to its reactivation. The venting of single component systems in a space environment has been performed numerous times and is well understood. Local nucleation occurs at warm, relatively massive parts of the system, which creates vapor and forces the bulk liquid out of the system. The remnants of the liquid will freeze, then evaporate over time through local heating. Because the Orion ATCS working fluid is a 50/50 mixture of water and inhibited propylene glycol, its boiling behavior was expected to differ from that of a pure fluid. It was thought that the relatively high vapor pressure water might evaporate preferentially, leaving behind a mixture enriched with the low vapor pressure propylene glycol, which would be vaporization ]resistant. Owing to this concern, a test was developed to compare the evaporation behavior of pure water, a 50/50 mixture of water and inhibited propylene glycol, and inhibited propylene glycol. The test was performed using room temperature fluids in an instrumented thin walled stainless steel vertical tube. The 1 in x 0.035 in wall tube was instrumented with surface thermocouples and encased in closed cell polyurethane foam. Reticulated polyurethane foam was placed inside the tube to reduce the convection currents. A vacuum system connected to the top of the tube set the pressure boundary condition. Tests were run for the three fluids at back pressures ranging from 1 to 18 torr. During each test, the mass of the test article was measured as it changed over time, as was its temperature and backpressure. The tests were successful. Somewhat surprisingly, the results showed that the evaporation behavior of the three fluids had more similarities than differences. The 50/50 mixture evaporated similarly to the pure water - albeit at a slower rate. The test results indicate that our extensive space - based experience with venting of single component fluids can be applied to the problem of Orion ATCS venting as long as the appropriate puts, takes, and caveats are applied.
Operational Experience with the Internal Thermal Control System Dual-Membrane Gas Trap
NASA Technical Reports Server (NTRS)
Leimkuehler, Thomas O.; Lukens, Clark; Reeves, Daniel R.; Holt, James M.
2003-01-01
A dual-membrane gas trap is currently used to remove non-condensed gases (NCG) from the Internal Thermal Control System (ITCS) coolant on board the International Space Station. The gas trap consists of concentric tube membrane pairs, comprised of outer hydrophilic tubes and inner hydrophobic fibers. Liquid coolant passes through the outer hydrophilic membrane, which traps the NCG. The inner hydrophobic fiber allows the trapped NCG to pass through and vent to the ambient atmosphere in the cabin. The purpose of the gas trap is to prevent gas bubbles from causing depriming, overspeed, and shutdown of the ITCS pump, and the current gas trap has performed flawlessly in this regard. However, because of actual operational conditions on-orbit, its gas removal performance and operational lifetime have been affected. This paper discusses experiences with several of these dual- membrane gas traps, including on-orbit gas venting rate, effects due to the presence of nickel in the ITCS coolant, and subsequent refurbishing to remove the nickel from the gas trap.
76 FR 44457 - Application of Regulations on Fuel Venting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-26
... GEnx-2B and GEnx-1B engines, respectively. These GE engines include an advanced technology fuel system...-0746] Application of Regulations on Fuel Venting AGENCY: Federal Aviation Administration (FAA), DOT... regarding fuel venting requirements. DATES: We must receive your comments by August 25, 2011. ADDRESSES...
Multifunctional Space Evaporator-Absorber-Radiator (SEAR)
NASA Technical Reports Server (NTRS)
Bue, Grant C.; Hodgson, Ed; Izenson, Mike; Chen, Weibo
2013-01-01
A system for non-venting thermal control for spacesuits was built by integrating two previously developed technologies, namely NASA's Spacesuit Water Membrane Evaporator (SWME), and Creare's flexible version of the Lithium Chloride Absorber Radiator (LCAR). This SEAR system was tested in relevant thermal vacuum conditions. These tests show that a 1 sq m radiator having about three times as much absorption media as in the test article would be required to support a 7 hour spacewalk. The serial flow arrangement of the LCAR of the flexible version proved to be inefficient for venting non-condensable gas (NCG). A different LCAR packaging arrangement was conceived wherein the Portable Life Support System (PLSS) housing would be made with a high-strength carbon fiber composite honeycomb, the cells of which would be filled with the chemical absorption media. This new packaging reduce the mass and volume impact of the SEAR on the Portable Life Support System (PLSS) compared to the flexible design. A 0.2 sq m panel with flight-like honeycomb geometry is being constructed and will be tested in thermal and thermal vacuum conditions. Design analyses forecast improved system performance and improved NCG control. A flight-like regeneration system also is also being built and tested. Design analyses for the structurally integrated prototype as well as the earlier test data show that SEAR is not only practical for spacesuits but also has useful applications in spacecraft thermal control.
Space Evaporator-Absorber-Radiator (SEAR)
NASA Technical Reports Server (NTRS)
Bue, Grant C.; Stephan, Ryan; Hodgson, Ed; Izenson, Mike; Chen, Weibo
2012-01-01
A system for non-venting thermal control for spacesuits was built by integrating two previously developed technologies, namely NASA s Spacesuit Water Membrane Evaporator (SWME), and Creare s flexible version of the Lithium Chloride Absorber Radiator (LCAR). This SEAR system was tested in relevant thermal vacuum conditions. These tests show that a 1 m2 radiator having about three times as much absorption media as in the test article would be required to support a 7 hour spacewalk. The serial flow arrangement of the LCAR of the flexible version proved to be inefficient for venting non-condensable gas (NCG). A different LCAR packaging arrangement was conceived wherein the Portable Life Support System (PLSS) housing would be made with a high-strength carbon fiber composite honeycomb, the cells of which would be filled with the chemical absorption media. This new packaging reduces the mass and volume impact of the SEAR on the Portable Life Support System (PLSS) compared to the flexible design. A 0.2 sq m panel with flight-like honeycomb geometry is being constructed and will be tested in thermal and thermal vacuum conditions. Design analyses forecast improved system performance and improved NCG control. A flight-like regeneration system also is also being built and tested. Design analyses for the structurally integrated prototype as well as the earlier test data show that SEAR is not only practical for spacesuits but also has useful applications in spacecraft thermal control.
NASA Astrophysics Data System (ADS)
Lauritano, C.; Ruocco, M.; Dattolo, E.; Buia, M. C.; Silva, J.; Santos, R.; Olivé, I.; Costa, M. M.; Procaccini, G.
2015-03-01
Submarine volcanic vents are being used as natural laboratories to assess the effects of CO2 on marine organisms and communities, as this gas is the main component of emissions. Seagrasses should positively react to increased dissolved carbon, but in vicinity of volcanic vents there may be toxic substances, that can have indirect effects on seagrasses. Here we analysed the expression of 35 stress-related genes in the Mediterranean keystone seagrass species P. oceanica in the vicinity of submerged volcanic vents located in the Islands of Ischia and Panarea, Italy, and compared them with those from control sites away from the influence of vents. Reverse Transcription-Quantitative Polymerase Chain Reaction (RT-qPCR) was used to characterize the expression levels of genes. Fifty one per cent of genes analysed showed significant expression changes. Metal detoxification genes were mostly down-regulated in relation to controls both in Ischia and Panarea locations, indicating that P. oceanica does not increase the synthesis of heavy metal detoxification proteins in response to the environmental conditions present at the two vents. The expression levels of genes involved in free radical detoxification indicate that, in contrast with Ischia, P. oceanica at the Panarea vent face stressors that result in the production of reactive oxygen species triggering antioxidant responses. In addition, heat shock proteins were also activated at Panarea and not at Ischia. Overall, our study reveals that P. oceanica is generally under higher stress in the vicinity of the vents at Panarea than at Ischia, possibly resulting from environmental and evolutionary differences existing between the two volcanic sites. This is the first study analysing gene responses in marine plants living near natural CO2 vents and our results call for a careful consideration of factors, other than CO2 and acidification, that can cause stress to seagrasses and other organisms near volcanic vents.
NASA Technical Reports Server (NTRS)
Parfitt, E. A.; Wilson, L.; Pinkerton, H.
1993-01-01
Long-lived eruptions from basaltic volcanoes involving episodic or steady activity indicate that a delicate balance has been struck between the rate of magma cooling in the dike system feeding the vent and the rate of magma supply to the dike system from a reservoir. We describe some key factors, involving the relationships between magma temperature, magma rheology, and dike geometry that control the nature of such eruptions.
System for pressure letdown of abrasive slurries
Kasper, Stanley
1991-01-01
A system and method for releasing erosive slurries from containment at high pressure without subjecting valves to highly erosive slurry flow. The system includes a pressure letdown tank disposed below the high-pressure tank, the two tanks being connected by a valved line communicating the gas phases and a line having a valve and choke for a transfer of liquid into the letdown tank. The letdown tank has a valved gas vent and a valved outlet line for release of liquid. In operation, the gas transfer line is opened to equalize pressure between tanks so that a low level of liquid flow occurs. The letdown tank is then vented, creating a high-pressure differential between the tanks. At this point, flow between tanks is controlled by the choke. High-velocity, erosive flow through a high-pressure outlet valve is prevented by equalizing the start up pressure and thereafter limiting flow with the choke.
Liquid Nitrogen (Oxygen Simulant) Thermodynamic Vent System Test Data Analysis
NASA Technical Reports Server (NTRS)
Hedayat, A.; Nelson, S. L.; Hastings, L. J.; Flachbart, R. H.; Tucker, S. P.
2005-01-01
In designing systems for the long-term storage of cryogens in low-gravity (space) environments, one must consider the effects of thermal stratification on tank pressure that will occur due to environmental heat leaks. During low-gravity operations, a Thermodynamic Vent System (TVS) concept is expected to maintain tank pressure without propellant resettling. A series of TVS tests was conducted at NASA Marshall Space Flight Center (MSFC) using liquid nitrogen (LN2) as a liquid oxygen (LO2) simulant. The tests were performed at tank til1 levels of 90%, 50%, and 25%, and with a specified tank pressure control band. A transient one-dimensional TVS performance program is used to analyze and correlate the test data for all three fill levels. Predictions and comparisons of ullage pressure and temperature and bulk liquid saturation pressure and temperature with test data are presented.
Vented Chill / No-Vent Fill of Cryogenic Propellant Tanks
NASA Technical Reports Server (NTRS)
Rhys, Noah O.; Foster, Lee W.; Martin, Adam K.; Stephens, Jonathan R.
2016-01-01
Architectures for extended duration missions often include an on-orbit replenishment of the space vehicle's cryogenic liquid propellants. Such a replenishment could be accomplished via a tank-to-tank transfer from a dedicated tanker or a more permanent propellant depot storage tank. Minimizing the propellant loss associated with transfer line and receiver propellant tank thermal conditioning is essential for mass savings. A new methodology for conducting tank-to-tank transfer while minimizing such losses has been demonstrated. Charge-Hold-Vent is the traditional methodology for conducting a tank-to-tank propellant transfer. A small amount of cryogenic liquid is introduced to chill the transfer line and propellant tank. As the propellant absorbs heat and undergoes a phase change, the tank internal pressure increases. The tank is then vented to relieve pressure prior to another charge of cryogenic liquid being introduced. This cycle is repeated until the transfer lines and tank are sufficiently chilled and the replenishment of the propellant tank is complete. This method suffers inefficiencies due to multiple chill and vent cycles within the transfer lines and associated feed system components. Additionally, this system requires precise measuring of cryogenic fluid delivery for each transfer, multiple valve cycling events, and other complexities associated with cycled operations. To minimize propellant loss and greatly simplify on-orbit operations, an alternate methodology has been designed and demonstrated. The Vented Chill / No Vent Fill method is a simpler, constant flow approach in which the propellant tank and transfer lines are only chilled once. The receiver tank is continuously vented as cryogenic liquid chills the transfer lines, tank mass and ullage space. Once chilled sufficiently, the receiver tank valve is closed and the tank is completely filled. Interestingly, the vent valve can be closed prior to receiver tank components reaching liquid saturation temperature. An incomplete fill results if insufficient energy is removed from the tank's thermal mass and ullage space. The key to successfully conducting the no vent fill is to assure that sufficient energy is removed from the system prior to closing the receiver tank vent valve. This paper will provide a description of the transfer methodology and test article, and will provide a discussion of test results.
NASA Astrophysics Data System (ADS)
Harp, A. G.; Valentine, G. A.
2018-06-01
In the article "Emplacement controls for the basaltic-andesitic radial dikes of Summer Coon volcano and implications for flank vents at stratovolcanoes", the vertical axis for Fig. 8 a was incorrectly labeled (i.e., the value for dikes per km2).
Diverse styles of submarine venting on the ultraslow spreading Mid-Cayman Rise
German, C. R.; Bowen, A.; Coleman, M. L.; Honig, D. L.; Huber, J. A.; Jakuba, M. V.; Kinsey, J. C.; Kurz, M. D.; Leroy, S.; McDermott, J. M.; de Lépinay, B. Mercier; Nakamura, K.; Seewald, J. S.; Smith, J. L.; Sylva, S. P.; Van Dover, C. L.; Whitcomb, L. L.; Yoerger, D. R.
2010-01-01
Thirty years after the first discovery of high-temperature submarine venting, the vast majority of the global mid-ocean ridge remains unexplored for hydrothermal activity. Of particular interest are the world’s ultraslow spreading ridges that were the last to be demonstrated to host high-temperature venting but may host systems particularly relevant to prebiotic chemistry and the origins of life. Here we report evidence for previously unknown, diverse, and very deep hydrothermal vents along the ∼110 km long, ultraslow spreading Mid-Cayman Rise (MCR). Our data indicate that the MCR hosts at least three discrete hydrothermal sites, each representing a different type of water-rock interaction, including both mafic and ultramafic systems and, at ∼5,000 m, the deepest known hydrothermal vent. Although submarine hydrothermal circulation, in which seawater percolates through and reacts with host lithologies, occurs on all mid-ocean ridges, the diversity of vent types identified here and their relative geographic isolation make the MCR unique in the oceans. These new sites offer prospects for an expanded range of vent-fluid compositions, varieties of abiotic organic chemical synthesis and extremophile microorganisms, and unparalleled faunal biodiversity—all in close proximity. PMID:20660317
Zero Power Warming (ZPW) Chamber Prototype Measurements, Barrow, Alaska, 2016
Shawn Serbin; Alistair Rogers; Kim Ely
2017-02-10
Data were collected during one season of prototyping associated with the development of a passive warming technology. An experimental chamber, the Zero Power Warming (ZPW) chamber, was fitted with apparatus to modulate venting of a field enclosure and enhance elevation of air temperature by solar radiation. The ZPW chamber was compared with a control chamber (Control) and an ambient open air plot (Ambient). The control chamber was identical to the ZPW chamber but lacked the apparatus necessary to modulate venting, the chamber vents in the control chamber were fixed open for the majority of the trial period. The three plots were located over Carex aquatilis growing in an area of moderately degraded permafrost. Chambers were placed on the same footprints that were used for a similar exercise in 2015 (no data) and therefore those plots had experienced some thaw and degradation prior to 2016. The following data were collected for 80 days at 1 minute intervals from within two chambers and an ambient plot: solar input, chamber venting, air temperature, relative humidity, soil temperature (at 5, 10 and 15 cm), soil moisture, downward and upward NIR.
View of building 11070 showing vents and forced air system ...
View of building 11070 showing vents and forced air system on east side, looking southwest. - Naval Ordnance Test Station Inyokern, China Lake Pilot Plant, Maintenance Shop, C Street, China Lake, Kern County, CA
40 CFR 63.166 - Standards: Sampling connection systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... defined in 40 CFR part 261. (c) In-situ sampling systems and sampling systems without purges are exempt..., closed-loop, or closed-vent system, except as provided in § 63.162(b) of this subpart. Gases displaced...-purge, closed-loop, or closed-vent system as required in paragraph (a) of this section shall: (1) Return...
Fissure near Cerberus Fossae with Tectonic Morphologies
2014-01-15
The linearity of the volcanic vent shown in this image observed by NASA Mars Reconnaissance Orbiter, in conjunction with evidence of lava flow from the vent, suggests control by combined volcano-tectonic processes.
NASA Technical Reports Server (NTRS)
Flachbart, R. H.; Hastings, L. J.; Hedayat, A.; Nelson, S. L.; Tucker, S. P.
2007-01-01
Due to its high specific impulse and favorable thermal properties for storage, liquid methane (LCH4) is being considered as a candidate propellant for exploration architectures. In order to gain an -understanding of any unique considerations involving micro-gravity pressure control with LCH4, testing was conducted at the Marshall Space Flight Center using the Multipurpose Hydrogen Test Bed (MHTB) to evaluate the performance of a spray-bar thermodynamic vent system (TVS) with subcooled LCH4 and gaseous helium (GHe) pressurant. Thirteen days of testing were performed in November 2006, with total tank heat leak conditions of about 715 W and 420 W at a fill level of approximately 90%. The TVS system was used to subcool the LCH4 to a liquid saturation pressure of approximately 55.2 kPa before the tank was pressurized with GHe to a total pressure of 165.5 kPa. A total of 23 TVS cycles were completed. The TVS successfully controlled the ullage pressure within a prescribed control band but did not maintain a stable liquid saturation pressure. This was likely. due to a TVS design not optimized for this particular propellant and test conditions, and possibly due to a large artificially induced heat input directly into the liquid. The capability to reduce liquid saturation pressure as well as maintain it within a prescribed control band, demonstrated that the TVS could be used to seek and maintain a desired liquid inlet temperature for an engine (at a cost of propellant lost through the TVS vent). One special test was conducted at the conclusion of the planned test activities. Reduction of the tank ullage pressure by opening the Joule-Thomson valve (JT) without operating the pump was attempted. The JT remained open for over 9300 seconds, resulting in an ullage pressure reduction of 30 kPa. The special test demonstrated the feasibility of using the JT valve for limited ullage pressure reduction in the event of a pump failure.
Centaur Propellant Thermal Conditioning Study
NASA Technical Reports Server (NTRS)
Blatt, M. H.; Pleasant, R. L.; Erickson, R. C.
1976-01-01
A wicking investigation revealed that passive thermal conditioning was feasible and provided considerable weight advantage over active systems using throttled vent fluid in a Centaur D-1s launch vehicle. Experimental wicking correlations were obtained using empirical revisions to the analytical flow model. Thermal subcoolers were evaluated parametrically as a function of tank pressure and NPSP. Results showed that the RL10 category I engine was the best candidate for boost pump replacement and the option showing the lowest weight penalty employed passively cooled acquisition devices, thermal subcoolers, dry ducts between burns and pumping of subcooler coolant back into the tank. A mixing correlation was identified for sizing the thermodynamic vent system mixer. Worst case mixing requirements were determined by surveying Centaur D-1T, D-1S, IUS, and space tug vehicles. Vent system sizing was based upon worst case requirements. Thermodynamic vent system/mixer weights were determined for each vehicle.
Code of Federal Regulations, 2012 CFR
2012-07-01
... each . . . You must . . . 1. Group 1 transfer rack a. Reduce emissions of total organic HAP by ≥98... through a closed-vent system to any combination of control devices (except a flare); or b. Reduce....982(d) and the requirements referenced therein; or d. Use a vapor balancing system designed and...
Code of Federal Regulations, 2014 CFR
2014-07-01
... each . . . You must . . . 1. Group 1 transfer rack a. Reduce emissions of total organic HAP by ≥98... through a closed-vent system to any combination of control devices (except a flare); or b. Reduce....982(d) and the requirements referenced therein; or d. Use a vapor balancing system designed and...
Code of Federal Regulations, 2010 CFR
2010-07-01
... each . . . You must . . . 1. Group 1 transfer rack a. Reduce emissions of total organic HAP by ≥98... through a closed-vent system to any combination of control devices (except a flare); or b. Reduce....982(d) and the requirements referenced therein; or d. Use a vapor balancing system designed and...
40 CFR 264.1033 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... § 264.1035(b)(4)(iii)(F). (h) An owner or operator using a carbon adsorption system such as a carbon...). (iii) A steam-assisted or nonassisted flare designed for and operated with an exit velocity, as... established as a requirement of § 264.1035(b)(4)(iii)(G), whichever is longer. (2) Replace the existing carbon...
40 CFR 264.1033 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... § 264.1035(b)(4)(iii)(F). (h) An owner or operator using a carbon adsorption system such as a carbon...). (iii) A steam-assisted or nonassisted flare designed for and operated with an exit velocity, as... established as a requirement of § 264.1035(b)(4)(iii)(G), whichever is longer. (2) Replace the existing carbon...
40 CFR 264.1033 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... § 264.1035(b)(4)(iii)(F). (h) An owner or operator using a carbon adsorption system such as a carbon...). (iii) A steam-assisted or nonassisted flare designed for and operated with an exit velocity, as... established as a requirement of § 264.1035(b)(4)(iii)(G), whichever is longer. (2) Replace the existing carbon...
Reveillaud, Julie; Reddington, Emily; McDermott, Jill; Algar, Christopher; Meyer, Julie L; Sylva, Sean; Seewald, Jeffrey; German, Christopher R; Huber, Julie A
2016-06-01
Warm fluids emanating from hydrothermal vents can be used as windows into the rocky subseafloor habitat and its resident microbial community. Two new vent systems on the Mid-Cayman Rise each exhibits novel geologic settings and distinctively hydrogen-rich vent fluid compositions. We have determined and compared the chemistry, potential energy yielding reactions, abundance, community composition, diversity, and function of microbes in venting fluids from both sites: Piccard, the world's deepest vent site, hosted in mafic rocks; and Von Damm, an adjacent, ultramafic-influenced system. Von Damm hosted a wider diversity of lineages and metabolisms in comparison to Piccard, consistent with thermodynamic models that predict more numerous energy sources at ultramafic systems. There was little overlap in the phylotypes found at each site, although similar and dominant hydrogen-utilizing genera were present at both. Despite the differences in community structure, depth, geology, and fluid chemistry, energetic modelling and metagenomic analysis indicate near functional equivalence between Von Damm and Piccard, likely driven by the high hydrogen concentrations and elevated temperatures at both sites. Results are compared with hydrothermal sites worldwide to provide a global perspective on the distinctiveness of these newly discovered sites and the interplay among rocks, fluid composition and life in the subseafloor. © 2015 The Authors. Environmental Microbiology published by Society for Applied Microbiology and John Wiley & Sons Ltd.
Code of Federal Regulations, 2012 CFR
2012-07-01
... process vents in Table 1 or 2 to this subpart. You must meet the CPMS requirements in paragraph (c) of... parameter specified in Table 5 to this subpart for each process vent control device specified in § 63.11925(b) that is used to comply with the emission limits for process vents in Table 1 or 2 to this subpart...
Code of Federal Regulations, 2014 CFR
2014-07-01
... process vents in Table 1 or 2 to this subpart. You must meet the CPMS requirements in paragraph (c) of... parameter specified in Table 5 to this subpart for each process vent control device specified in § 63.11925(b) that is used to comply with the emission limits for process vents in Table 1 or 2 to this subpart...
Code of Federal Regulations, 2013 CFR
2013-07-01
... process vents in Table 1 or 2 to this subpart. You must meet the CPMS requirements in paragraph (c) of... parameter specified in Table 5 to this subpart for each process vent control device specified in § 63.11925(b) that is used to comply with the emission limits for process vents in Table 1 or 2 to this subpart...
The stability of amino acids at submarine hydrothermal vent temperatures
NASA Technical Reports Server (NTRS)
Bada, Jeffrey L.; Miller, Stanley L.; Zhao, Meixun
1995-01-01
It has been postulated that amino acid stability at hydrothermal vent temperatures is controlled by a metastable thermodynamic equilibrium rather than by kinetics. Experiments reported here demonstrate that the amino acids are irreversibly destroyed by heating at 240 C and that quasi-equilibrium calculations give misleading descriptions of the experimental observations. Equilibrium thermodynamic calculations are not applicable to organic compounds under high-temperature submarine vent conditions.
40 CFR Table 5 of Subpart Bbbbbbb... - Reporting Requirements
Code of Federal Regulations, 2013 CFR
2013-07-01
... vent streams from equipment in target HAP service to a PM control device with a PM percent reduction efficiency of 95 percent (98 percent for new sources) or an outlet concentration of 0.03 gr/dscf or less a... requirement to route all process vent streams from equipment in target HAP service to a PM control device that...
40 CFR Table 5 of Subpart Bbbbbbb... - Reporting Requirements
Code of Federal Regulations, 2014 CFR
2014-07-01
... vent streams from equipment in target HAP service to a PM control device with a PM percent reduction efficiency of 95 percent (98 percent for new sources) or an outlet concentration of 0.03 gr/dscf or less a... requirement to route all process vent streams from equipment in target HAP service to a PM control device that...
40 CFR Table 5 of Subpart Bbbbbbb... - Reporting Requirements
Code of Federal Regulations, 2012 CFR
2012-07-01
... vent streams from equipment in target HAP service to a PM control device with a PM percent reduction efficiency of 95 percent (98 percent for new sources) or an outlet concentration of 0.03 gr/dscf or less a... requirement to route all process vent streams from equipment in target HAP service to a PM control device that...
40 CFR Table 5 of Subpart Bbbbbbb... - Reporting Requirements
Code of Federal Regulations, 2010 CFR
2010-07-01
... vent streams from equipment in target HAP service to a PM control device with a PM percent reduction efficiency of 95 percent (98 percent for new sources) or an outlet concentration of 0.03 gr/dscf or less a... requirement to route all process vent streams from equipment in target HAP service to a PM control device that...
40 CFR Table 5 of Subpart Bbbbbbb... - Reporting Requirements
Code of Federal Regulations, 2011 CFR
2011-07-01
... vent streams from equipment in target HAP service to a PM control device with a PM percent reduction efficiency of 95 percent (98 percent for new sources) or an outlet concentration of 0.03 gr/dscf or less a... requirement to route all process vent streams from equipment in target HAP service to a PM control device that...
Sensitivity Analysis of Algan/GAN High Electron Mobility Transistors to Process Variation
2008-02-01
delivery system gas panel including both hydride and alkyl delivery modules and the vent/valve configurations [14...Reactor Gas Delivery Systems A basic schematic diagram of an MOCVD reactor delivery gas panel is shown in Figure 13. The reactor gas delivery...system, or gas panel , consists of a network of stainless steel tubing, automatic valves and electronic mass flow controllers (MFC). There are separate
Code of Federal Regulations, 2013 CFR
2013-07-01
... composed of piping, connections, and, if necessary, flow-inducing devices that transport gas or vapor from an emission source to a control device. If gas or vapor from regulated equipment are routed to a process (e.g., to a petroleum refinery fuel gas system), the process shall not be considered a closed vent...
Code of Federal Regulations, 2011 CFR
2011-07-01
... composed of piping, connections, and, if necessary, flow-inducing devices that transport gas or vapor from an emission source to a control device. If gas or vapor from regulated equipment are routed to a process (e.g., to a petroleum refinery fuel gas system), the process shall not be considered a closed vent...
Code of Federal Regulations, 2012 CFR
2012-07-01
... composed of piping, connections, and, if necessary, flow-inducing devices that transport gas or vapor from an emission source to a control device. If gas or vapor from regulated equipment are routed to a process (e.g., to a petroleum refinery fuel gas system), the process shall not be considered a closed vent...
Code of Federal Regulations, 2014 CFR
2014-07-01
... composed of piping, connections, and, if necessary, flow-inducing devices that transport gas or vapor from an emission source to a control device. If gas or vapor from regulated equipment are routed to a process (e.g., to a petroleum refinery fuel gas system), the process shall not be considered a closed vent...
40 CFR 63.987 - Flare requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Emission Standards for Closed Vent Systems, Control Devices, Recovery Devices and Routing to a Fuel Gas... the additional cycles. (ii) The net heating value of the gas being combusted in a flare shall be..., ultra-violet beam sensor, or infrared sensor) capable of continuously detecting that at least one pilot...
Remote control flare stack igniter for combustible gases
NASA Technical Reports Server (NTRS)
Ray, W. L.
1972-01-01
Device has been designed and developed for igniting nonrecoverable combustible gases and sustaining combustion of gases evolving from various gas vent stacks. Igniter is superior to existing systems because of simplicity of operation, low cost fabrication, installation, operational and maintainability features, and excellent reliability in all phases of required operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... cement by either the wet or dry process. (b) Bypass means any system that prevents all or a portion of the kiln or clinker cooler exhaust gases from entering the main control device and ducts the gases... cooler emissions. (c) Bypass stack means the stack that vents exhaust gases to the atmosphere from the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... cement by either the wet or dry process. (b) Bypass means any system that prevents all or a portion of the kiln or clinker cooler exhaust gases from entering the main control device and ducts the gases... cooler emissions. (c) Bypass stack means the stack that vents exhaust gases to the atmosphere from the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... cement by either the wet or dry process. (b) Bypass means any system that prevents all or a portion of the kiln or clinker cooler exhaust gases from entering the main control device and ducts the gases... cooler emissions. (c) Bypass stack means the stack that vents exhaust gases to the atmosphere from the...
Code of Federal Regulations, 2010 CFR
2010-07-01
... cement by either the wet or dry process. (b) Bypass means any system that prevents all or a portion of the kiln or clinker cooler exhaust gases from entering the main control device and ducts the gases... cooler emissions. (c) Bypass stack means the stack that vents exhaust gases to the atmosphere from the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... cement by either the wet or dry process. (b) Bypass means any system that prevents all or a portion of the kiln or clinker cooler exhaust gases from entering the main control device and ducts the gases... cooler emissions. (c) Bypass stack means the stack that vents exhaust gases to the atmosphere from the...
40 CFR 63.11397 - What General Provisions apply to this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fibers Production Area Sources Other Requirements and Information § 63.11397 What General Provisions... vent system and control device, flare, or recovery device), fiber spinning line, AN storage tank..., your notification of compliance status required by § 63.9(h) must include the following information: (1...
40 CFR 63.11397 - What General Provisions apply to this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Fibers Production Area Sources Other Requirements and Information § 63.11397 What General Provisions... vent system and control device, flare, or recovery device), fiber spinning line, AN storage tank..., your notification of compliance status required by § 63.9(h) must include the following information: (1...
TankSIM: A Cryogenic Tank Performance Prediction Program
NASA Technical Reports Server (NTRS)
Bolshinskiy, L. G.; Hedayat, A.; Hastings, L. J.; Moder, J. P.; Schnell, A. R.; Sutherlin, S. G.
2015-01-01
Developed for predicting the behavior of cryogenic liquids inside propellant tanks under various environmental and operating conditions. Provides a multi-node analysis of pressurization, ullage venting and thermodynamic venting systems (TVS) pressure control using axial jet or spray bar TVS. Allows user to combine several different phases for predicting the liquid behavior for the entire flight mission timeline or part of it. Is a NASA in-house code, based on FORTRAN 90-95 and Intel Visual FORTRAN compiler, but can be used on any other platform (Unix-Linux, Compaq Visual FORTRAN, etc.). The last Version 7, released on December 2014, included detailed User's Manual. Includes the use of several RefPROP subroutines for calculating fluid properties.
14 CFR 34.11 - Standard for fuel venting emissions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Emissions (New and In-Use Aircraft Gas Turbine Engines) § 34.11 Standard for fuel venting emissions. (a) No fuel venting emissions shall be discharged into the atmosphere from any new or in-use aircraft gas... include one of the following: (1) Incorporation of an FAA-approved system that recirculates the fuel back...
14 CFR 34.11 - Standard for fuel venting emissions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Emissions (New and In-Use Aircraft Gas Turbine Engines) § 34.11 Standard for fuel venting emissions. (a) No fuel venting emissions shall be discharged into the atmosphere from any new or in-use aircraft gas... include one of the following: (1) Incorporation of an FAA-approved system that recirculates the fuel back...
14 CFR 34.11 - Standard for fuel venting emissions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Emissions (New and In-Use Aircraft Gas Turbine Engines) § 34.11 Standard for fuel venting emissions. (a) No fuel venting emissions shall be discharged into the atmosphere from any new or in-use aircraft gas... include one of the following: (1) Incorporation of an FAA-approved system that recirculates the fuel back...
NASA Technical Reports Server (NTRS)
Bleacher, Jacob E.; Glaze, Lori S.; Greeley, Ronald; Hauber, Ernst; Baloga, Stephen; Sakimoto, Susan E. H.; Williams, David A.; Glotch, Timothy D.
2009-01-01
A field of small volcanic vents south of Pavonis Mons was mapped with each vent assigned a two-dimensional data point. Nearest neighbor and two-point azimuth analyses were applied to the resulting location data. Nearest neighbor results show that vents within this field are spatially random in a Poisson sense, suggesting that the vents formed independently of each other without sharing a centralized magma source at shallow depth. Two-point azimuth results show that the vents display north-trending alignment relationships between one another. This trend corresponds to the trends of faults and fractures of the Noachian-aged Claritas Fossae, which might extend into our study area buried beneath more recently emplaced lava flows. However, individual elongate vent summit structures do not consistently display the same trend. The development of the volcanic field appears to display tectonic control from buried Noachian-aged structural patterns on small, ascending magma bodies while the surface orientations of the linear vents might reflect different, younger tectonic patterns. These results suggest a complex interaction between magma ascension through the crust, and multiple, older, buried Tharsis-related tectonic structures.
NASA Astrophysics Data System (ADS)
Robert, K.; Matabos, M.; Sarrazin, J.; Sarradin, P.; Lee, R. W.; Juniper, K.
2010-12-01
Hydrothermal vent environments are among the most dynamic benthic habitats in the ocean. The relative roles of physical and biological factors in shaping vent community structure remain unclear. Undersea cabled observatories offer the power and bandwidth required for high-resolution, time-series study of the dynamics of vent communities and the physico-chemical forces that influence them. The NEPTUNE Canada cabled instrument array at the Endeavour hydrothermal vents provides a unique laboratory for researchers to conduct long-term, integrated studies of hydrothermal vent ecosystem dynamics in relation to environmental variability. Beginning in September-October 2010, NEPTUNE Canada (NC) will be deploying a multi-disciplinary suite of instruments on the Endeavour Segment of the Juan de Fuca Ridge. Two camera and sensor systems will be used to study ecosystem dynamics in relation to hydrothermal discharge. These studies will make use of new experimental protocols for time-series observations that we have been developing since 2008 at other observatory sites connected to the VENUS and NC networks. These protocols include sampling design, camera calibration (i.e. structure, position, light, settings) and image analysis methodologies (see communication by Aron et al.). The camera systems to be deployed in the Main Endeavour vent field include a Sidus high definition video camera (2010) and the TEMPO-mini system (2011), designed by IFREMER (France). Real-time data from three sensors (O2, dissolved Fe, temperature) integrated with the TEMPO-mini system will enhance interpretation of imagery. For the first year of observations, a suite of internally recording temperature probes will be strategically placed in the field of view of the Sidus camera. These installations aim at monitoring variations in vent community structure and dynamics (species composition and abundances, interactions within and among species) in response to changes in environmental conditions at different temporal scales. High-resolution time-series studies also provide a mean of studying population dynamics, biological rhythms, organism growth and faunal succession. In addition to programmed time-series monitoring, the NC infrastructure will also permit manual and automated modification of observational protocols in response to natural events. This will enhance our ability to document potentially critical but short-lived environmental forces affecting vent communities.
Simulating Electrochemistry of Hydrothermal Vents on Enceladus and Other Ocean Worlds
NASA Astrophysics Data System (ADS)
Barge, L. M.; Krause, F. C.; Jones, J. P.; Billings, K.; Sobron, P.
2017-12-01
Gradients generated in hydrothermal systems provide a significant source of free energy for chemosynthetic life, and may play a role in present-day habitability on ocean worlds such as Enceladus that are thought to host hydrothermal activity. Hydrothermal vents are similar in some ways to typical fuel cell devices: redox/pH gradients between seawater and hydrothermal fluid are analogous to the oxidant and fuel reservoirs; conductive natural mineral deposits are analogous to electrodes; and, in hydrothermal chimneys, the porous chimney wall can function as a separator or ion-exchange membrane. Electrochemistry, founded on quantitative study of redox and other chemical disequilibria as well as the chemistry of interfaces, is uniquely suited to studying these systems. We have performed electrochemical studies to better understand the catalytic potential of seafloor minerals and vent chimneys, using samples from a black smoker vent chimney as an initial demonstration. Fuel cell experiments with electrodes made from black smoker chimney material accurately simulated the redox reactions that occur in a geological setting with this particular catalyst. Similar methods with other geo-catalysts (natural or synthetic) could be utilized to test which redox reactions or metabolisms could be driven in other hydrothermal systems, including putative vent systems on other worlds.
NASA Technical Reports Server (NTRS)
Shriver, C. B.; Apisa, J. N.; Kariotis, A. H.
1971-01-01
Results of the research and development program to determine the purge and vent characteristics of the GAC-9 insulation system are summarized. The work scope comprised: (1) literature survey; (2) design improvement and insulation effort; (3) testing; and (4) evaluation of test results. Program objectives to be realized are: (1) definition of purge gas flow characteristics of the GAC-9 insulation system through laboratory measurements; and (2) demonstration of insulation effectiveness as a system for prelaunch purging and launch venting of the 76-cm diameter calorimeter, which is a subscale model simulating a realistic type of GAC-9 insulation application.
Characterization of Magma-Driven Hydrothermal Systems at Oceanic Spreading Centers
NASA Astrophysics Data System (ADS)
Farough, A.; Lowell, R. P.; Corrigan, R.
2012-12-01
Fluid circulation in high-temperature hydrothermal systems involves complex water-rock chemical reactions and phase separation. Numerical modeling of reactive transport in multi-component, multiphase systems is required to obtain a full understanding of the characteristics and evolution of hydrothermal vent systems. We use a single-pass parameterized model of high-temperature hydrothermal circulation at oceanic spreading centers constrained by observational parameters such as vent temperature, heat output, and vent field area, together with surface area and depth of the sub-axial magma chamber, to deduce fundamental hydrothermal parameters such as mass flow rate, bulk permeability, conductive boundary layer thickness at the base of the system, magma replenishment rate, and residence time in the discharge zone. All of these key subsurface characteristics are known for fewer than 10 sites out of 300 known hydrothermal systems. The principal limitations of this approach stem from the uncertainty in heat output and vent field area. For systems where data are available on partitioning of heat and chemical output between focused and diffuse flow, we determined the fraction of high-temperature vent fluid incorporated into diffuse flow using a two-limb single pass model. For EPR 9°50` N and ASHES, the diffuse flow temperatures calculated assuming conservative mixing are nearly equal to the observed temperatures indicating that approximately 80%-90% of the hydrothermal heat output occurs as high-temperature flow derived from magmatic heat even though most of the heat output appears as low-temperature diffuse discharge. For the Main Endeavour Field and Lucky Strike, diffuse flow fluids show significant conductive cooling and heating respectively. Finally, we calculate the transport of various geochemical constituents in focused and diffuse flow at the vent field scale and compare the results with estimates of geochemical transports from the Rainbow hydrothermal field where diffuse flow is absent.
Heavy metals from Kueishantao shallow-sea hydrothermal vents, offshore northeast Taiwan
NASA Astrophysics Data System (ADS)
Chen, Xue-Gang; Lyu, Shuang-Shuang; Garbe-Schönberg, Dieter; Lebrato, Mario; Li, Xiaohu; Zhang, Hai-Yan; Zhang, Ping-Ping; Chen, Chen-Tung Arthur; Ye, Ying
2018-04-01
Shallow water hydrothermal vents are a source of heavy metals leading to their accumulation in marine organisms that manage to live under extreme environmental conditions. This is the case at Kueishantao (KST) shallow-sea vents system offshore northeast Taiwan, where the heavy metal distribution in vent fluids and ambient seawater is poorly understood. This shallow vent is an excellent natural laboratory to understand how heavy and volatile metals behave in the nearby water column and ecosystem. Here, we investigated the submarine venting of heavy metals from KST field and its impact on ambient surface seawater. The total heavy metal concentrations in the vent fluids and vertical plumes were 1-3 orders of magnitude higher than the overlying seawater values. When compared with deep-sea hydrothermal systems, the estimated KST end-member fluids exhibited much lower concentrations of transition metals (e.g., Fe and Mn) but comparable concentrations of toxic metals such as Pb and As. This may be attributed to the lower temperature of the KST reaction zone and transporting fluids. Most of the heavy metals (Fe, Mn, As, Y, and Ba) in the plumes and seawater mainly originated from hydrothermal venting, while Cd and Pb were largely contributed by external sources such as contaminated waters (anthropogenic origin). The spatial distribution of heavy metals in the surface seawater indicated that seafloor venting impacts ambient seawater. The measurable influence of KST hydrothermal activity, however, was quite localized and limited to an area of < 1 km2. The estimated annual fluxes of heavy metals emanating from the yellow KST hydrothermal vent were: 430-2600 kg Fe, 24-145 kg Mn, 5-32 kg Ba, 10-60 kg As, 0.3-1.9 kg Cd, and 2-10 kg Pb. This study provides important data on heavy metals from a shallow-sea hydrothermal field, and it helps to better understand the environmental impact of submarine shallow hydrothermal venting.
Advances in detection of diffuse seafloor venting using structured light imaging.
NASA Astrophysics Data System (ADS)
Smart, C.; Roman, C.; Carey, S.
2016-12-01
Systematic, remote detection and high resolution mapping of low temperature diffuse hydrothermal venting is inefficient and not currently tractable using traditional remotely operated vehicle (ROV) mounted sensors. Preliminary results for hydrothermal vent detection using a structured light laser sensor were presented in 2011 and published in 2013 (Smart) with continual advancements occurring in the interim. As the structured light laser passes over active venting, the projected laser line effectively blurs due to the associated turbulence and density anomalies in the vent fluid. The degree laser disturbance is captured by a camera collecting images of the laser line at 20 Hz. Advancements in the detection of the laser and fluid interaction have included extensive normalization of the collected laser data and the implementation of a support vector machine algorithm to develop a classification routine. The image data collected over a hydrothermal vent field is then labeled as seafloor, bacteria or a location of venting. The results can then be correlated with stereo images, bathymetry and backscatter data. This sensor is a component of an ROV mounted imaging suite which also includes stereo cameras and a multibeam sonar system. Originally developed for bathymetric mapping, the structured light laser sensor, and other imaging suite components, are capable of creating visual and bathymetric maps with centimeter level resolution. Surveys are completed in a standard mowing the lawn pattern completing a 30m x 30m survey with centimeter level resolution in under an hour. Resulting co-registered data includes, multibeam and structured light laser bathymetry and backscatter, stereo images and vent detection. This system allows for efficient exploration of areas with diffuse and small point source hydrothermal venting increasing the effectiveness of scientific sampling and observation. Recent vent detection results collected during the 2013-2015 E/V Nautilus seasons will be presented. Smart, C. J. and Roman, C. and Carey, S. N. (2013) Detection of diffuse seafloor venting using structured light imaging, Geochemistry, Geophysics, Geosystems, 14, 4743-4757
The vent microbiome: patterns and drivers
NASA Astrophysics Data System (ADS)
Pachiadaki, M.
2015-12-01
Microbial processes within deep-sea hydrothermal vents affect the global biogeochemical cycles. Still, there are significant gaps in our understanding of the microbiology and the biogeochemistry of deep-sea hydrothermal systems. Vents differ in temperature, host rock composition and fluid chemistry; factors that are hypothesized to shape the distribution of the microbial communities, their metabolic capabilities and their activities. Using large-scale single cell genomics, we obtained insights into the genomic content of several linkages of a diffuse flow vent. The genomes show high metabolic versatility. Sulfur oxidation appears to be predominant but there is the potential of using a variety of e- donors and acceptors to obtain energy. To further assess the ecological importance of the vent auto- and heterotrophs, the global biogeography of the analyzed lineages will be investigated by fragment recruitment of metagenomes produced from the same site as well as other hydrothermal systems. Metatranscriptomic and metaproteomic data will be integrated to examine the expression of the predominant metabolic pathways and thus the main energy sources driving chemoautotrophic production. The comparative analysis of the key players and associated pathways among various vent sites that differ in physicochemical characteristics is anticipated to decipher the patterns and drivers of the global dispersion and the local diversification of the vent microbiome.
Investigating the role of small vent volcanism during the development of Tharsis Province, Mars
NASA Astrophysics Data System (ADS)
Richardson, J. A.; Bleacher, J. E.; Connor, C.; Connor, L.; Glaze, L. S.
2014-12-01
Clusters of tens to hundreds of small volcanic vents have recently been recognized as a major component of Tharsis Province volcanism. These volcanic fields are formed from distributed-style, possibly monogenetic, volcanism and are composed of low sloped edifices with diameters of tens of kilometers and heights of tens to hundreds of meters. We report a new catalog of these small volcanic vents, now available through the USGS Astrogeology Science Center. This catalog was created with the use of gridded topographic data from the Mars Orbiter Laser Altimeter (MOLA) and images from the Thermal Emission Imaging System (THEMIS) and the High Resolution Stereo Camera (HRSC). We are now investigating isolated clusters of distributed volcanism in Tharsis with this dataset. We hypothesize that these clusters are formed from significant magmatic events that played a large role in the development of Tharsis. Currently, the catalog contains 1075 unique volcanic vents in the Tharsis Province. With the catalog, potentially isolated volcano clusters are identified with vent density estimation. Vent intensity for clusters is found to be 1 vent per 1000 sq km or less. Crater retention rates for one such cluster, Syria Planum, indicates that these distributed volcanic systems might continue as long as 700 Ma, or that monogenetic volcanic systems overprint older systems. Using a modified basal outlining algorithm with MOLA gridded data, shield volumes are found to be between 1-20 cubic km. Current results show distributed-style volcanism occuring in Tharsis orders of magnitude more dispersed than analogous volcano clusers on Earth, while individual edifices are found to be an order of magnitude larger than volcanoes in Earth clusters. Proof of concept results are reported for three identified clusters: Arsia Mons Caldera, Syria Planum, and Southern Pavonis Mons.
Zero Gravity Cryogenic Vent System Concepts for Upper Stages
NASA Technical Reports Server (NTRS)
Flachbart, Robin H.; Holt, James B.; Hastings, Leon J.
1999-01-01
The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space. Venting without resettling would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray bar system consists of a recirculation pump, a parallel flow concentric tube, heat exchanger, and a spray bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy is required. a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point. the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating, boil-off losses.
NASA Astrophysics Data System (ADS)
Andersen, C.; Theissen-Krah, S.; Hannington, M.; Rüpke, L.; Petersen, S.
2017-06-01
The potential of mining seafloor massive sulfide deposits for metals such as Cu, Zn, and Au is currently debated. One key challenge is to predict where the largest deposits worth mining might form, which in turn requires understanding the pattern of subseafloor hydrothermal mass and energy transport. Numerical models of heat and fluid flow are applied to illustrate the important role of fault zone properties (permeability and width) in controlling mass accumulation at hydrothermal vents at slow spreading ridges. We combine modeled mass-flow rates, vent temperatures, and vent field dimensions with the known fluid chemistry at the fault-controlled Logatchev 1 hydrothermal field of the Mid-Atlantic Ridge. We predict that the 135 kilotons of SMS at this site (estimated by other studies) can have accumulated with a minimum depositional efficiency of 5% in the known duration of hydrothermal venting (58,200 year age of the deposit). In general, the most productive faults must provide an efficient fluid pathway while at the same time limit cooling due to mixing with entrained cold seawater. This balance is best met by faults that are just wide and permeable enough to control a hydrothermal plume rising through the oceanic crust. Model runs with increased basal heat input, mimicking a heat flow contribution from along-axis, lead to higher mass fluxes and vent temperatures, capable of significantly higher SMS accumulation rates. Nonsteady state conditions, such as the influence of a cooling magmatic intrusion beneath the fault zone, also can temporarily increase the mass flux while sustaining high vent temperatures.
NASA Technical Reports Server (NTRS)
Behar, Alberto; Matthews, Jaret; Venkateswaran, Kasthuri; Bruckner, James; Basic, Goran; So, Edmond; Rivadeneyra, Cesar
2005-01-01
This paper provides a physical description of the current system, as well as a summary of the preliminary tests conducted in 2005: a pressure chamber test, a dive test in a 30 foot dive pool, and a dive operation at a hydrothermal vent off the northern coast of Iceland.
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices...) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550, you...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices...) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550, you...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices... (c) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices... (c) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices... (c) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Inorganic HAP Emissions From Catalytic Reforming Units As stated in § 63.1567(b)(1), you shall meet each requirement in the following table that applies to you. If you use this type of control device for your vent . . . You shall install and operate this type of continuous monitoring system . . . 1. Wet scrubber...
Vent modification of large ribbon parachutes to enhance cluster performance
NASA Technical Reports Server (NTRS)
Kolega, D. J.; Woodis, W. R.; Reuter, J. D.
1986-01-01
Due to uneven load sharing and lagging inflation rates, the design of the Large Main Parachute (LMP) cluster, used to recover the Space Shuttle steel case Solid Rocket Boosters, had to be modified. The cause of the problem was excessive variation in effective porosity in the crown area of the LMP during first stage inflation. The design modification consisted of adding horizontal ribbons above the existing vent band to reduce the vent porosity and better control the position and attitude of the vent lines. Performance of modified LMP's since introduction indicates that the load sharing between the clustered chutes has been significantly improved.
Spatial and Alignment Analyses for a field of Small Volcanic Vents South of Pavonis Mons Mars
NASA Technical Reports Server (NTRS)
Bleacher, J. E.; Glaze, L. S.; Greeley, R.; Hauber, E.; Baloga, S. M.; Sakimoto, S. E. H.; Williams, D. A.; Glotch, T. D.
2008-01-01
The Tharsis province of Mars displays a variety of small volcanic vent (10s krn in diameter) morphologies. These features were identified in Mariner and Viking images [1-4], and Mars Orbiter Laser Altimeter (MOLA) data show them to be more abundant than originally observed [5,6]. Recent studies are classifying their diverse morphologies [7-9]. Building on this work, we are mapping the location of small volcanic vents (small-vents) in the Tharsis province using MOLA, Thermal Emission Imaging System, and High Resolution Stereo Camera data [10]. Here we report on a preliminary study of the spatial and alignment relationships between small-vents south of Pavonis Mons, as determined by nearest neighbor and two-point azimuth statistical analyses. Terrestrial monogenetic volcanic fields display four fundamental characteristics: 1) recurrence rates of eruptions,2 ) vent abundance, 3) vent distribution, and 4) tectonic relationships [11]. While understanding recurrence rates typically requires field measurements, insight into vent abundance, distribution, and tectonic relationships can be established by mapping of remotely sensed data, and subsequent application of spatial statistical studies [11,12], the goal of which is to link the distribution of vents to causal processes.
Predicting Backdrafting and Spillage for Natural-Draft Gas Combustion Appliances: Validating VENT-II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rapp, Vi H.; Pastor-Perez, Albert; Singer, Brett C.
2013-04-01
VENT-II is a computer program designed to provide detailed analysis of natural draft and induced draft combustion appliance vent-systems (i.e., furnace or water heater). This program is capable of predicting house depressurization thresholds that lead to backdrafting and spillage of combustion appliances; however, validation reports of the program being applied for this purpose are not readily available. The purpose of this report is to assess VENT-II’s ability to predict combustion gas spillage events due to house depressurization by comparing VENT-II simulated results with experimental data for four appliance configurations. The results show that VENT-II correctly predicts depressurizations resulting in spillagemore » for natural draft appliances operating in cold and mild outdoor conditions, but not for hot conditions. In the latter case, the predicted depressurizations depend on whether the vent section is defined as part of the vent connector or the common vent when setting up the model. Overall, the VENTII solver requires further investigation before it can be used reliably to predict spillage caused by depressurization over a full year of weather conditions, especially where hot conditions occur.« less
40 CFR 63.7710 - What are my operation and maintenance requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
... gases from mold vents in pouring areas and pouring stations that use a sand mold system. This operation... including quality assurance procedures. (iv) How the bag leak detection system will be maintained including...) Procedures for providing an ignition source to mold vents of sand mold systems in each pouring area and...
Numerical Modeling of Hydrothermal Circulation at the Longqi-1 Field: Southwest Indian Ridge
NASA Astrophysics Data System (ADS)
Guo, Z.; Lowell, R. P.; Tao, C.; Rupke, L.; Lewis, K. C.
2017-12-01
The Longqi-1(Dragon Flag) hydrothermal field is the first high-temperature hydrothermal system observed on the ultra-slow spreading Southwest Indian Ridge. Hydrothermal vents with temperatures near 380 °C are localized by detachment faulting within which extensional deformation likely increases permeability to provide preferred pathways for hydrothermal discharge. To better understand the Longqi-1 circulation system, we construct a 2-D numerical simulations in a NaCl- H2O fluid constrained by key observational data, such as vent temperature and heat output, crust structure derived from seismic data, and fault zone geometry deduced from seismicity. Heat output from AUV surveys is estimated to be » 300 ± 100 MW, and this value, in conjunction with vent temperature was used with the single-pass modeling approach to obtain an average permeability of 10-13 m-2 within the fault zone. In analogy with other fault-controlled hydrothermal systems such as Logatchev-1 we assume a lower background permeability of 10-14 m-2. The top boundary of the system is permeable and maintained at constant seafloor pressure, which is divided into two parts by the detachment fault. The pressure of the southern part is lower than the northern part to simulate the effect of the seafloor topography. The top boundary is upstream weighted to allow high temperature fluid to exit, while recharging fluid is maintained at 10°C. The bottom boundary is impermeable and is given a fixed temperature distribution at a depth of 7 km below the seafloor. The highest value Tmax is maintained over a distance given lateral distance and decreases linearly towards two ends to 300 °C. The salinity is set to 3.2 wt. % NaCl, and the simulations are assumed to be single phase. The results show that with a 7 km deep circulation system, Tmax = 550 oC gives a reasonable temperature and heat output of venting plume.We infer that the observed high salinity results from serpentinization reactions. Assuming all salinity in excess of seawater comes from uptake of H2O during serpentinization, we can estimate the rate of reaction and heat release of serpentinezation based on a simplified reaction equation, observed heat output and salinity data. The estimated rate of heat release during serpentinization is 20 MW. This is approximately 10% of the heat output of Dragon Flag vent field.
Code of Federal Regulations, 2014 CFR
2014-07-01
... or live steam. Closed-vent system means a system that is not open to the atmosphere and is composed... emissions from individual process vents, stacks, open pieces of process equipment, equipment leaks... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
Code of Federal Regulations, 2013 CFR
2013-07-01
... or live steam. Closed-vent system means a system that is not open to the atmosphere and is composed... emissions from individual process vents, stacks, open pieces of process equipment, equipment leaks... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
40 CFR 63.653 - Monitoring, recordkeeping, and implementation plan for emissions averaging.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) For each emission point included in an emissions average, the owner or operator shall perform testing, monitoring, recordkeeping, and reporting equivalent to that required for Group 1 emission points complying... internal floating roof, external roof, or a closed vent system with a control device, as appropriate to the...
NASA Astrophysics Data System (ADS)
Verdoni, A. P.; Denker, C.; Varsik, J. R.; Shumko, S.; Nenow, J.; Coulter, R.
2007-09-01
The New Solar Telescope (NST) is a 1.6-meter off-axis Gregory-type telescope with an equatorial mount and an open optical support structure. To mitigate the temperature fluctuations along the exposed optical path, the effects of local/dome-related seeing have to be minimized. To accomplish this, NST will be housed in a 5/8-sphere fiberglass dome that is outfitted with 14 active vents evenly spaced around its perimeter. The 14 vents house louvers that open and close independently of one another to regulate and direct the passage of air through the dome. In January 2006, 16 thermal probes were installed throughout the dome and the temperature distribution was measured. The measurements confirmed the existence of a strong thermal gradient on the order of 5° Celsius inside the dome. In December 2006, a second set of temperature measurements were made using different louver configurations. In this study, we present the results of these measurements along with their integration into the thermal control system (ThCS) and the overall telescope control system (TCS).
The effect of venting on cookoff of a melt-castable explosive (Comp-B)
Hobbs, Michael L.; Kaneshige, Michael J.
2015-03-01
Occasionally, our well-controlled cookoff experiments with Comp-B give anomalous results when venting conditions are changed. For example, a vented experiment may take longer to ignite than a sealed experiment. In the current work, we show the effect of venting on thermal ignition of Comp-B. We use Sandia’s Instrumented Thermal Ignition (SITI) experiment with various headspace volumes in both vented and sealed geometries to study ignition of Comp-B. In some of these experiments, we have used a boroscope to observe Comp-B as it melts and reacts. We propose that the mechanism for ignition involves TNT melting, dissolution of RDX, and complexmore » bubbly liquid flow. High pressure inhibits bubble formation and flow is significantly reduced. At low pressure, a vigorous dispersed bubble flow was observed.« less
Measure Guideline: Passive Vents
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, David; Neri, Robin
2016-02-05
This document addresses the use of passive vents as a source of outdoor air in multifamily buildings. The challenges associated with implementing passive vents and the factors affecting performance are outlined. A comprehensive design methodology and quantified performance metrics are provided. Two hypothetical design examples are provided to illustrate the process. This document is intended to be useful to designers, decision-makers, and contractors implementing passive ventilation strategies. It is also intended to be a resource for those responsible for setting high-performance building program requirements, especially pertaining to ventilation and outdoor air. To ensure good indoor air quality, a dedicated sourcemore » of outdoor air is an integral part of high-performance buildings. Presently, there is a lack of guidance pertaining to the design and installation of passive vents, resulting in poor system performance. This report details the criteria necessary for designing, constructing, and testing passive vent systems to enable them to provide consistent and reliable levels of ventilation air from outdoors.« less
NASA Astrophysics Data System (ADS)
Stucker, Valerie K.; Walker, Sharon L.; de Ronde, Cornel E. J.; Caratori Tontini, Fabio; Tsuchida, Shinji
2017-10-01
The Hinepuia volcanic center is made up of two distinct edifices aligned northwest to southeast, with an active cone complex in the SE. Hinepuia is one of several active volcanoes in the northern segment of the Kermadec arc. Regional magnetic data show no evidence for large-scale hydrothermal alteration at Hinepuia, yet plume data confirm present-day hydrothermal discharge, suggesting that the hydrothermal system may be too young to have altered the host rocks with respect to measurable changes in magnetic signal. Gravity data are consistent with crustal thinning and shallow mantle under the volcanic center. Following the discovery of hydrothermal plumes over Hinepuia, the submersible Shinkai 6500 was used to explore the SE cone and sample hydrothermal fluids. The chemistry of hydrothermal fluids from submarine arc and backarc volcanoes is typically dominated by water-rock interactions and/or magmatic degassing. Chemical analyses of vent fluids show that Hinepuia does not quite fit either traditional model. Moreover, the Hinepuia samples fall between those typically ascribed to both end-member fluid types when plotted on a K-Mg-SO4 ternary diagram. Due to evidence of strong degassing, abundant native sulfur deposition, and H2S presence, the vent sampled at Hinepuia is ultimately classified as a magmatic-hydrothermal system with a water-rock influence. This vent is releasing water vapor and magmatic volatiles with a notable lack of salinity due to subcritical boiling and phase separation. Magmatic-hydrothermal fluid chemistry appears to be controlled by a combination of gas flux, phase separation processes, and volcano evolution and/or distance from the magma source.
NASA Astrophysics Data System (ADS)
Tanaka, Yoshikazu
1993-06-01
Geomagnetic changes associated with the volcanic activity of Aso volcano were detected with a dense network of continuously recording proton-precession magnetometers during the period from June 1989 to June 1990. Magnetic date clearly indicate that changes in the magnetization within the volcano are most probably caused by temperature changes. This activity can be divided into five stages, which are characterized by magnetization and demagnetization of the volcano. These magnetic changes with durations of a few months are definitely correlated with some typical volcanic events at the crater as well as the volcanic tremor activity. The demagnetization stage appears when the vent is covered by a water pool or the volcanic activity is enhanced. The magnetization stage follows the opening of a vent and several large explosions which make the vent permeable. The source of magnetic changes lies at a depth of about 200 m below the crater rim in the southwestern part of the active crater. Magnetic moments responsible for observed magnetic changes at stages 1, 2 and 4 are 3.4, -5.2 and -2.2 Wbm, respectively. The corresponding source volume is estimated as a single sphere of radius 40-50 m or a spherical shell of 100 m or so. An effective mechanism of rapid heating/cooling exists, which is ascribed to the interaction of groundwater and superheated vapor, i.e., a shallow hydrothermal system. This hydrothermal system driven by the surface cap of the vent, controls every feature of the eruptions at the final outlet of Aso volcano.
Code of Federal Regulations, 2011 CFR
2011-07-01
... epoxides, and that are using ECO as a control technique to reduce epoxide emissions in order to comply with... provisions of this section. The owner or operator that is using ECO in order to comply with the emission... used to further reduce the HAP emissions from a process vent already controlled by ECO, then the owner...
Diverse styles of submarine venting on the ultra-slow spreading Mid-Cayman Rise (Invited)
NASA Astrophysics Data System (ADS)
German, C. R.; Bowen, A.; Coleman, M. L.; Honig, D. L.; Huber, J. A.; Jakuba, M.; Kinsey, J. C.; Kurz, M. D.; Leroy, S.; McDermott, J.; Mercier de Lepinay, B. F.; Nakamura, K.; Seewald, J.; Smith, J.; Sylva, S.; van Dover, C. L.; Whitcomb, L. L.; Yoerger, D. R.
2010-12-01
Thirty years after the first discovery of high-temperature submarine venting, the vast majority of the global Mid Ocean Ridge remains unexplored for hydrothermal activity. Of particular interest are the world’s ultra-slow spreading ridges which were the last to be demonstrated to host high-temperature venting, but may host systems particularly relevant to pre-biotic chemistry and the origins of life. Here we report first evidence for diverse and very deep hydrothermal vents along the ~110 km long, ultra-slow spreading Mid-Cayman Rise collected using a combination of CTD-rosette operations and dives of the Hybrid Remotely Operated Vehicle (HROV) Nereus in 2009 followed by shore based work-up of samples for geochemical and microbiological analyses. Our data indicate that the Mid-Cayman Rise hosts at least three discrete hydrothermal sites, each representing a different type of water-rock interaction, including both mafic and ultra-mafic systems and, at ~5000 m, the deepest known hydrothermal vent. Although submarine hydrothermal circulation, in which seawater percolates through and reacts with host lithologies, occurs on all mid-ocean ridges, the diversity of vent-types identified here and their relative geographic isolation make the Mid-Cayman Rise unique in the oceans. These new sites offer prospects for: an expanded range of vent-fluid compositions; varieties of abiotic organic chemical synthesis and extremophile microorganisms; and unparalleled faunal biodiversity - all in close proximity.
Code of Federal Regulations, 2011 CFR
2011-07-01
... flash steam from the digester or live steam. Closed-vent system means a system that is not open to the... this subpart, including emissions from individual process vents, stacks, open pieces of process... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
Code of Federal Regulations, 2010 CFR
2010-07-01
... flash steam from the digester or live steam. Closed-vent system means a system that is not open to the... this subpart, including emissions from individual process vents, stacks, open pieces of process... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
Code of Federal Regulations, 2012 CFR
2012-07-01
... flash steam from the digester or live steam. Closed-vent system means a system that is not open to the... this subpart, including emissions from individual process vents, stacks, open pieces of process... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
46 CFR 153.1500 - Venting system rupture disks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Venting system rupture disks. 153.1500 Section 153.1500 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Maintenance § 153...
46 CFR 153.1500 - Venting system rupture disks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Venting system rupture disks. 153.1500 Section 153.1500 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Maintenance § 153...
46 CFR 153.1500 - Venting system rupture disks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Venting system rupture disks. 153.1500 Section 153.1500 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Maintenance § 153...
46 CFR 153.1500 - Venting system rupture disks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Venting system rupture disks. 153.1500 Section 153.1500 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Maintenance § 153...
46 CFR 153.1500 - Venting system rupture disks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Venting system rupture disks. 153.1500 Section 153.1500 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Maintenance § 153...
Solar Thermal Upper Stage Liquid Hydrogen Pressure Control Testing and Analytical Modeling
NASA Technical Reports Server (NTRS)
Olsen, A. D.; Cady, E. C.; Jenkins, D. S.; Chandler, F. O.; Grayson, G. D.; Lopez, A.; Hastings, L. J.; Flachbart, R. H.; Pedersen, K. W.
2012-01-01
The demonstration of a unique liquid hydrogen (LH2) storage and feed system concept for solar thermal upper stage was cooperatively accomplished by a Boeing/NASA Marshall Space Flight Center team. The strategy was to balance thermodynamic venting with the engine thrusting timeline during a representative 30-day mission, thereby, assuring no vent losses. Using a 2 cubic m (71 cubic ft) LH2 tank, proof-of-concept testing consisted of an engineering checkout followed by a 30-day mission simulation. The data were used to anchor a combination of standard analyses and computational fluid dynamics (CFD) modeling. Dependence on orbital testing has been incrementally reduced as CFD codes, combined with standard modeling, continue to be challenged with test data such as this.
24 CFR 3280.612 - Tests and inspection.
Code of Federal Regulations, 2012 CFR
2012-04-01
... to a pressure test. The test shall be made by subjecting the system to air or water at 100 psi for 15 minutes without loss of pressure. (b) Drainage and vent system and plumbing fixtures. The waste and vent... plugged, the entire system shall be subjected to a 2-inch (manometer) water column air pressure test. If...
24 CFR 3280.612 - Tests and inspection.
Code of Federal Regulations, 2014 CFR
2014-04-01
... to a pressure test. The test shall be made by subjecting the system to air or water at 100 psi for 15 minutes without loss of pressure. (b) Drainage and vent system and plumbing fixtures. The waste and vent... plugged, the entire system shall be subjected to a 2-inch (manometer) water column air pressure test. If...
24 CFR 3280.612 - Tests and inspection.
Code of Federal Regulations, 2013 CFR
2013-04-01
... to a pressure test. The test shall be made by subjecting the system to air or water at 100 psi for 15 minutes without loss of pressure. (b) Drainage and vent system and plumbing fixtures. The waste and vent... plugged, the entire system shall be subjected to a 2-inch (manometer) water column air pressure test. If...
24 CFR 3280.612 - Tests and inspection.
Code of Federal Regulations, 2011 CFR
2011-04-01
... to a pressure test. The test shall be made by subjecting the system to air or water at 100 psi for 15 minutes without loss of pressure. (b) Drainage and vent system and plumbing fixtures. The waste and vent... plugged, the entire system shall be subjected to a 2-inch (manometer) water column air pressure test. If...
NASA Astrophysics Data System (ADS)
Barta, Daniel J.; Lange, Kevin; Anderson, Molly; Vonau, Walter
2016-07-01
Planetary protection represents an additional set of requirements that generally have not been considered by developers of technologies for Environmental Control and Life Support Systems (ECLSS). Forward contamination concerns will affect release of gases and discharge of liquids and solids, including what may be left behind after planetary vehicles are abandoned upon return to Earth. A crew of four using a state of the art ECLSS could generate as much as 4.3 metric tons of gaseous, liquid and solid wastes and trash during a 500-day surface stay. These may present issues and concerns for both planetary protection and planetary science. Certainly, further closure of ECLSS systems will be of benefit by greater reuse of consumable products and reduced generation of waste products. It can be presumed that planetary protection will affect technology development by constraining how technologies can operate: limiting or prohibiting certain kinds of operations or processes (e.g. venting); necessitating that other kinds of operations be performed (e.g. sterilization; filtration of vent lines); prohibiting what can be brought on a mission (e.g. extremophiles); creating needs for new capabilities/ technologies (e.g. containment). Although any planned venting could include filtration to eliminate micro-organisms from inadvertently exiting the spacecraft, it may be impossible to eliminate or filter habitat structural leakage. Filtration will add pressure drops impacting size of lines and ducts, affect fan size and energy requirements, and add consumable mass. Technologies that may be employed to remove biomarkers and microbial contamination from liquid and solid wastes prior to storage or release may include mineralization technologies such as incineration, super critical wet oxidation and pyrolysis. These technologies, however, come with significant penalties for mass, power and consumables. This paper will estimate the nature and amounts of materials generated during Mars transit and surface stays that may be impacted by planetary protection requirements or be controlled for the protection of planetary science.
Ogino, Tetsuya; Maegawa, Shingo; Shigeno, Shuichi; Fujikura, Katsunori; Toyohara, Haruhiko
2018-01-01
The environments around deep-sea hydrothermal vents are very harsh conditions for organisms due to the possibility of exposure to highly toxic compounds and extremely hot venting there. Despite such extreme environments, some indigenous species have thrived there. Alvinellid worms (Annelida) are among the organisms best adapted to high-temperature and oxidatively stressful venting regions. Although intensive studies of the adaptation of these worms to the environments of hydrothermal vents have been made, little is known about the worms' sensory adaptation to the severe chemical conditions there. To examine the sensitivity of the vent-endemic worm Paralvinella hessleri to low pH and oxidative stress, we determined the concentration of acetic acid and hydrogen peroxide that induced avoidance behavior of this worm, and compared these concentrations to those obtained for related species inhabiting intertidal zones, Thelepus sp. The concentrations of the chemicals that induced avoidance behavior of P. hessleri were 10-100 times lower than those for Thelepus sp. To identify the receptors for these chemicals, chemical avoidance tests were performed with the addition of ruthenium red, a blocker of transient receptor potential (TRP) channels. This treatment suppressed the chemical avoidance behavior of P. hessleri, which suggests that TRP channels are involved in the chemical avoidance behavior of this species. Our results revealed for the first time hypersensitive detection systems for acid and for oxidative stress in the vent-endemic worm P. hessleri, possibly mediated by TRP channels, suggesting that such sensory systems may have facilitated the adaptation of this organism to harsh vent environments.
Near-Seafloor Magnetic Exploration of Submarine Hydrothermal Systems in the Kermadec Arc
NASA Astrophysics Data System (ADS)
Caratori Tontini, F.; de Ronde, C. E. J.; Tivey, M.; Kinsey, J. C.
2014-12-01
Magnetic data can provide important information about hydrothermal systems because hydrothermal alteration can drastically reduce the magnetization of the host volcanic rocks. Near-seafloor data (≤70 m altitude) are required to map hydrothermal systems in detail; Autonomous Underwater Vehicles (AUVs) are the ideal platform to provide this level of resolution. Here, we show the results of high-resolution magnetic surveys by the ABE and Sentry AUVs for selected submarine volcanoes of the Kermadec arc. 3-D magnetization models derived from the inversion of magnetic data, when combined with high resolution seafloor bathymetry derived from multibeam surveys, provide important constraints on the subseafloor geometry of hydrothermal upflow zones and the structural control on the development of seafloor hydrothermal vent sites as well as being a tool for the discovery of previously unknown hydrothermal sites. Significant differences exist between the magnetic expressions of hydrothermal sites at caldera volcanoes ("donut" pattern) and cones ("Swiss cheese" pattern), respectively. Subseafloor 3-D magnetization models also highlight structural differences between focused and diffuse vent sites.
Millard, Andrew D; Pearce, David; Zwirglmaier, Katrin
2016-04-01
In this study, which was carried out within the ChEsSO consortium project (Chemosynthetically driven ecosystems south of the Polar Front), we sampled two hydrothermal vent sites on the East Scotia Ridge, Scotia Sea, one in the Kemp Caldera, South Sandwich Arc and one in the Bransfield Strait, north-west of the Antarctic Peninsula, which exhibit strong differences in their chemical characteristics. We compared a subset of their bacteriophage population by Sanger- and 454-sequencing of g23, which codes for the major capsid protein of T4likeviruses. We found that the sites differ vastly in their bacteriophage diversity, which reflects the differences in the chemical conditions and therefore putatively the differences in microbial hosts living at these sites. Comparing phage diversity in the vent samples to other aquatic samples, the vent samples formed a distinct separate cluster, which also included the non-vent control samples that were taken several hundred meters above the vent chimneys. This indicates that the influence of the vents on the microbial population and therefore also the bacteriophage population extends much further than anticipated. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
An authoritative global database for active submarine hydrothermal vent fields
NASA Astrophysics Data System (ADS)
Beaulieu, Stace E.; Baker, Edward T.; German, Christopher R.; Maffei, Andrew
2013-11-01
The InterRidge Vents Database is available online as the authoritative reference for locations of active submarine hydrothermal vent fields. Here we describe the revision of the database to an open source content management system and conduct a meta-analysis of the global distribution of known active vent fields. The number of known active vent fields has almost doubled in the past decade (521 as of year 2009), with about half visually confirmed and others inferred active from physical and chemical clues. Although previously known mainly from mid-ocean ridges (MORs), active vent fields at MORs now comprise only half of the total known, with about a quarter each now known at volcanic arcs and back-arc spreading centers. Discoveries in arc and back-arc settings resulted in an increase in known vent fields within exclusive economic zones, consequently reducing the proportion known in high seas to one third. The increase in known vent fields reflects a number of factors, including increased national and commercial interests in seafloor hydrothermal deposits as mineral resources. The purpose of the database now extends beyond academic research and education and into marine policy and management, with at least 18% of known vent fields in areas granted or pending applications for mineral prospecting and 8% in marine protected areas.
A hydrothermal seep on the Costa Rica margin: middle ground in a continuum of reducing ecosystems
Levin, Lisa A.; Orphan, Victoria J.; Rouse, Greg W.; Rathburn, Anthony E.; Ussler, William; Cook, Geoffrey S.; Goffredi, Shana K.; Perez, Elena M.; Waren, Anders; Grupe, Benjamin M.; Chadwick, Grayson; Strickrott, Bruce
2012-01-01
Upon their initial discovery, hydrothermal vents and methane seeps were considered to be related but distinct ecosystems, with different distributions, geomorphology, temperatures, geochemical properties and mostly different species. However, subsequently discovered vents and seep systems have blurred this distinction. Here, we report on a composite, hydrothermal seep ecosystem at a subducting seamount on the convergent Costa Rica margin that represents an intermediate between vent and seep ecosystems. Diffuse flow of shimmering, warm fluids with high methane concentrations supports a mixture of microbes, animal species, assemblages and trophic pathways with vent and seep affinities. Their coexistence reinforces the continuity of reducing environments and exemplifies a setting conducive to interactive evolution of vent and seep biota. PMID:22398162
46 CFR 154.1735 - Methyl acetylene-propadiene mixture.
Code of Federal Regulations, 2011 CFR
2011-10-01
... mixture must have a refrigeration system without vapor compression or have a refrigeration system with the... separate cargo piping, vent piping, and refrigeration equipment for methyl acetylene-propadiene that are segregated from other cargo piping, vent piping and refrigeration equipment on the vessel. [CGD 74-289, 44 FR...
46 CFR 154.1735 - Methyl acetylene-propadiene mixture.
Code of Federal Regulations, 2014 CFR
2014-10-01
... mixture must have a refrigeration system without vapor compression or have a refrigeration system with the... separate cargo piping, vent piping, and refrigeration equipment for methyl acetylene-propadiene that are segregated from other cargo piping, vent piping and refrigeration equipment on the vessel. [CGD 74-289, 44 FR...
46 CFR 154.1735 - Methyl acetylene-propadiene mixture.
Code of Federal Regulations, 2013 CFR
2013-10-01
... mixture must have a refrigeration system without vapor compression or have a refrigeration system with the... separate cargo piping, vent piping, and refrigeration equipment for methyl acetylene-propadiene that are segregated from other cargo piping, vent piping and refrigeration equipment on the vessel. [CGD 74-289, 44 FR...
46 CFR 154.1735 - Methyl acetylene-propadiene mixture.
Code of Federal Regulations, 2012 CFR
2012-10-01
... mixture must have a refrigeration system without vapor compression or have a refrigeration system with the... separate cargo piping, vent piping, and refrigeration equipment for methyl acetylene-propadiene that are segregated from other cargo piping, vent piping and refrigeration equipment on the vessel. [CGD 74-289, 44 FR...
46 CFR 154.1735 - Methyl acetylene-propadiene mixture.
Code of Federal Regulations, 2010 CFR
2010-10-01
... mixture must have a refrigeration system without vapor compression or have a refrigeration system with the... separate cargo piping, vent piping, and refrigeration equipment for methyl acetylene-propadiene that are segregated from other cargo piping, vent piping and refrigeration equipment on the vessel. [CGD 74-289, 44 FR...
TankSIM: A Cryogenic Tank Performance Prediction Program
NASA Technical Reports Server (NTRS)
Bolshinskiy, L. G.; Hedayat, A.; Hastings, L. J.; Moder, J. P.; Schnell, A. R.; Sutherlin, S. G.
2015-01-01
Accurate prediction of the thermodynamic state of the cryogenic propellants in launch vehicle tanks is necessary for mission planning and successful execution. Cryogenic propellant storage and transfer in space environments requires that tank pressure be controlled. The pressure rise rate is determined by the complex interaction of external heat leak, fluid temperature stratification, and interfacial heat and mass transfer. If the required storage duration of a space mission is longer than the period in which the tank pressure reaches its allowable maximum, an appropriate pressure control method must be applied. Therefore, predictions of the pressurization rate and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning of future space exploration missions. This paper describes an analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. It is written in the FORTRAN 90 language and can be compiled with any Visual FORTRAN compiler. A thermodynamic vent system (TVS) is used to achieve tank pressure control. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, and mixing. Details of the TankSIM program and comparisons of its predictions with test data for liquid hydrogen and liquid methane will be presented in the final paper.
Study of cryogenic propellant systems for loading the space shuttle. Part 2: Hydrogen systems
NASA Technical Reports Server (NTRS)
Steward, W. G.
1975-01-01
Computer simulation studies of liquid hydrogen fill and vent systems for the space shuttle are studied. The computer programs calculate maximum and minimum permissible flow rates during cooldown as limited by thermal stress considerations, fill line cooldown time, pressure drop, flow rates, vapor content, vent line pressure drop and vent line discharge temperature. The input data for these programs are selected through graphic displays which schematically depict the part of the system being analyzed. The computed output is also displayed in the form of printed messages and graphs. Digital readouts of graph coordinates may also be obtained. Procedures are given for operation of the graphic display unit and the associated minicomputer and timesharing computer.
An analysis of bipropellant neutralization for spacecraft refueling operations
NASA Technical Reports Server (NTRS)
Kauffman, David
1987-01-01
Refueling of satellites on orbit with storable propellants will involve venting part or all of the pressurant gas from the propellant tanks. This gas will be saturated with propellant vapor, and it may also have significant amounts of entrained fine droplets of propellant. The two most commonly used bipropellants, monomethyl hydrazine (MMH) and nitrogen tetroxide (N2O4), are highly reactive and toxic. Various possible ways of neutralizing the vented propellants are examined. The amount of propellant vented in a typical refueling operation is shown to be in the range of 0.2 to 5% of the tank capacity. Four potential neutralization schemes are examined: chemical decomposition, chemical reaction, condensation and adsorption. Chemical decomposition to essentially inert materials is thermodynamically feasible for both MMH and N2O4. It would be the simplest and easiest neutralization method to implement. Chemical decomposition would require more complex control. Condensation would require a refrigeration system and a very efficent phase separator. Adsorption is likely to be much heavier. A preliminary assessment of the four neutralization shemes is presented, along with suggested research and development plans.
The Genome of Deep-Sea Vent Chemolithoautotroph Thiomicrospira crunogena XCL-2
Scott, Kathleen M; Sievert, Stefan M; Abril, Fereniki N; Ball, Lois A; Barrett, Chantell J; Blake, Rodrigo A; Boller, Amanda J; Chain, Patrick S. G; Clark, Justine A; Davis, Carisa R; Detter, Chris; Do, Kimberly F; Dobrinski, Kimberly P; Faza, Brandon I; Fitzpatrick, Kelly A; Freyermuth, Sharyn K; Harmer, Tara L; Hauser, Loren J; Hügler, Michael; Kerfeld, Cheryl A; Klotz, Martin G; Kong, William W; Land, Miriam; Lapidus, Alla; Larimer, Frank W; Longo, Dana L; Lucas, Susan; Malfatti, Stephanie A; Massey, Steven E; Martin, Darlene D; McCuddin, Zoe; Meyer, Folker; Moore, Jessica L; Ocampo, Luis H; Paul, John H; Paulsen, Ian T; Reep, Douglas K; Ren, Qinghu; Ross, Rachel L; Sato, Priscila Y; Thomas, Phaedra; Tinkham, Lance E; Zeruth, Gary T
2006-01-01
Presented here is the complete genome sequence of Thiomicrospira crunogena XCL-2, representative of ubiquitous chemolithoautotrophic sulfur-oxidizing bacteria isolated from deep-sea hydrothermal vents. This gammaproteobacterium has a single chromosome (2,427,734 base pairs), and its genome illustrates many of the adaptations that have enabled it to thrive at vents globally. It has 14 methyl-accepting chemotaxis protein genes, including four that may assist in positioning it in the redoxcline. A relative abundance of coding sequences (CDSs) encoding regulatory proteins likely control the expression of genes encoding carboxysomes, multiple dissolved inorganic nitrogen and phosphate transporters, as well as a phosphonate operon, which provide this species with a variety of options for acquiring these substrates from the environment. Thiom. crunogena XCL-2 is unusual among obligate sulfur-oxidizing bacteria in relying on the Sox system for the oxidation of reduced sulfur compounds. The genome has characteristics consistent with an obligately chemolithoautotrophic lifestyle, including few transporters predicted to have organic allocrits, and Calvin-Benson-Bassham cycle CDSs scattered throughout the genome. PMID:17105352
2001-08-08
KENNEDY SPACE CENTER, Fla. -- Floodlights reveal the Space Shuttle Discovery after rollback of the Rotating Service Structure in preparation for launch on mission STS-105. Above the external tank, the “beanie cap” is poised, waiting for loading of the propellants. The cap, or vent hood, is on the end of the gaseous oxygen vent arm that allows gaseous oxygen vapors to vent away from the Space Shuttle. Below, on either side of the orbiter’s tail are the tail service masts that support the fluid, gas and electrical requirements of the orbiter’s liquid oxygen and liquid hydrogen aft T-0 umbilicals. On the mission, Discovery will be transporting the Expedition Three crew and several scientific experiments and payloads to the International Space Station, including the Early Ammonia Servicer (EAS) tank. The EAS, which will support the thermal control subsystems until a permanent system is activated, will be attached to the Station during two spacewalks. The three-member Expedition Two crew will be returning to Earth aboard Discovery after a five-month stay on the Station. Launch is scheduled for 5:38 p.m. EDT Aug. 9
40 CFR 63.8240 - What are my monitoring requirements?
Code of Federal Regulations, 2012 CFR
2012-07-01
...) National Emission Standards for Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali...-product hydrogen stream, each end box ventilation system vent, and each mercury thermal recovery unit vent...
Schneider, David J.; Vallance, James W.; Wessels, Rick L.; Logan, Matthew; Ramsey, Michael S.; Sherrod, David R.; Scott, William E.; Stauffer, Peter H.
2008-01-01
A helicopter-mounted thermal imaging radiometer documented the explosive vent-clearing and effusive phases of the eruption of Mount St. Helens in 2004. A gyrostabilized gimbal controlled by a crew member housed the radiometer and an optical video camera attached to the nose of the helicopter. Since October 1, 2004, the system has provided thermal and video observations of dome growth. Flights conducted as frequently as twice daily during the initial month of the eruption monitored rapid changes in the crater and 1980-86 lava dome. Thermal monitoring decreased to several times per week once dome extrusion began. The thermal imaging system provided unique observations, including timely recognition that the early explosive phase was phreatic, location of structures controlling thermal emissions and active faults, detection of increased heat flow prior to the extrusion of lava, and recognition of new lava extrusion. The first spines, 1 and 2, were hotter when they emerged (maximum temperature 700-730°C) than subsequent spines insulated by as much as several meters of fault gouge. Temperature of gouge-covered spines was about 200°C where they emerged from the vent, and it decreased rapidly with distance from the vent. The hottest parts of these spines were as high as 500-730°C in fractured and broken-up regions. Such temperature variation needs to be accounted for in the retrieval of eruption parameters using satellite-based techniques, as such features are smaller than pixels in satellite images.
Environmental controls on chemoautotrophic primary producers at deep-sea vents
NASA Astrophysics Data System (ADS)
Le Bris, Nadine; Mullineaux, Lauren; Sievert, Stefan
2014-05-01
High biomasses and fast growth rates of dominant chemosynthetic species characterize hydrothermal ecosystems, raising the issue of their contribution to energy transfer and carbon cycling in the deep-sea. Addressing this issue, however, needs to account for the temporal instability of hydrothermal systems, both, in terms of biological colonization and habitat conditions. Volcanic eruptions on mid-ocean ridges offer the opportunity to investigate the environmental conditions favoring the successive modes of chemoautotrophic primary production (i.e. free living microbes and symbiotic invertebrates). In that perspective, habitat-scale approaches distinguish from vent field-scale approaches based on fluid composition and provide relevant information on environmental constraints exerted at different stages of colonization focusing on parameters linked with physiological limits and available energy. Investigation of habitat physicochemical properties along a typical successional sequence of recolonization at 9°50'N EPR diffuse-flow vents, between 2006 and 2014, was performed in order to examine potential changes in environmental features associated with chemoautotrophic primary producers, from early microbial colonizers to symbiotic invertebrates. Combined in situ measurements of temperature, pH and hydrogen sulfide were used and their variability documented over a series of assemblages characterizing recolonization stages. The distributions of mature assemblages of dominant invertebrate species associate with substantial differences in habitat conditions, pointing to a strong influence of habitat properties on potential productivity. Among the differences observed, however, the amplitude and rate of environmental fluctuation appear more important than average conditions in the succession, highlighting the role of spatial heterogeneity and temporal dynamics as a control on primary producers. Invertebrate species acting as engineer species are expected to play a primary role in the rate of organic carbon formed over the lifetime of a vent and potentially transferred to adjacent ecosystems.
Visualization of the air flow behind the automotive benchmark vent
NASA Astrophysics Data System (ADS)
Pech, Ondrej; Jedelsky, Jan; Caletka, Petr; Jicha, Miroslav
2015-05-01
Passenger comfort in cars depends on appropriate function of the cabin HVAC system. A great attention is therefore paid to the effective function of automotive vents and proper formation of the flow behind the ventilation outlet. The article deals with the visualization of air flow from the automotive benchmark vent. The visualization was made for two different shapes of the inlet channel connected to the benchmark vent. The smoke visualization with the laser knife was used. The influence of the shape of the inlet channel to the airflow direction, its enlargement and position of air flow axis were investigated.
Lamare, Miles D; Liddy, Michelle; Uthicke, Sven
2016-11-30
Laboratory experiments suggest that calcifying developmental stages of marine invertebrates may be the most ocean acidification (OA)-sensitive life-history stage and represent a life-history bottleneck. To better extrapolate laboratory findings to future OA conditions, developmental responses in sea urchin embryos/larvae were compared under ecologically relevant in situ exposures on vent-elevated pCO 2 and ambient pCO 2 coral reefs in Papua New Guinea. Echinometra embryos/larvae were reared in meshed chambers moored in arrays on either venting reefs or adjacent non-vent reefs. After 24 and 48 h, larval development and morphology were quantified. Compared with controls (mean pH (T) = 7.89-7.92), larvae developing in elevated pCO 2 vent conditions (pH (T) = 7.50-7.72) displayed a significant reduction in size and increased abnormality, with a significant correlation of seawater pH with both larval size and larval asymmetry across all experiments. Reciprocal transplants (embryos from vent adults transplanted to control conditions, and vice versa) were also undertaken to identify if adult acclimatization can translate resilience to offspring (i.e. transgenerational processes). Embryos originating from vent adults were, however, no more tolerant to reduced pH. Sea temperature and chlorophyll-a concentrations (i.e. larval nutrition) did not contribute to difference in larval size, but abnormality was correlated with chlorophyll levels. This study is the first to examine the response of marine larvae to OA scenarios in the natural environment where, importantly, we found that stunted and abnormal development observed in situ are consistent with laboratory observations reported in sea urchins, in both the direction and magnitude of the response. © 2016 The Author(s).
Liddy, Michelle; Uthicke, Sven
2016-01-01
Laboratory experiments suggest that calcifying developmental stages of marine invertebrates may be the most ocean acidification (OA)-sensitive life-history stage and represent a life-history bottleneck. To better extrapolate laboratory findings to future OA conditions, developmental responses in sea urchin embryos/larvae were compared under ecologically relevant in situ exposures on vent-elevated pCO2 and ambient pCO2 coral reefs in Papua New Guinea. Echinometra embryos/larvae were reared in meshed chambers moored in arrays on either venting reefs or adjacent non-vent reefs. After 24 and 48 h, larval development and morphology were quantified. Compared with controls (mean pH(T) = 7.89–7.92), larvae developing in elevated pCO2 vent conditions (pH(T) = 7.50–7.72) displayed a significant reduction in size and increased abnormality, with a significant correlation of seawater pH with both larval size and larval asymmetry across all experiments. Reciprocal transplants (embryos from vent adults transplanted to control conditions, and vice versa) were also undertaken to identify if adult acclimatization can translate resilience to offspring (i.e. transgenerational processes). Embryos originating from vent adults were, however, no more tolerant to reduced pH. Sea temperature and chlorophyll-a concentrations (i.e. larval nutrition) did not contribute to difference in larval size, but abnormality was correlated with chlorophyll levels. This study is the first to examine the response of marine larvae to OA scenarios in the natural environment where, importantly, we found that stunted and abnormal development observed in situ are consistent with laboratory observations reported in sea urchins, in both the direction and magnitude of the response. PMID:27903867
Chemical environments of submarine hydrothermal systems
NASA Technical Reports Server (NTRS)
Shock, Everett L.
1992-01-01
Perhaps because black-smoker chimneys make tremendous subjects for magazine covers, the proposal that submarine hydrothermal systems were involved in the origin of life has caused many investigators to focus on the eye-catching hydrothermal vents. In much the same way that tourists rush to watch the spectacular eruptions of Old Faithful geyser with little regard for the hydrology of the Yellowstone basin, attention is focused on the spectacular, high-temperature hydrothermal vents to the near exclusion of the enormous underlying hydrothermal systems. Nevertheless, the magnitude and complexity of geologic structures, heat flow, and hydrologic parameters which characterize the geyser basins at Yellowstone also characterize submarine hydrothermal systems. However, in the submarine systems the scale can be considerably more vast. Like Old Faithful, submarine hydrothermal vents have a spectacular quality, but they are only one fascinating aspect of enormous geologic systems operating at seafloor spreading centers throughout all of the ocean basins. A critical study of the possible role of hydrothermal processes in the origin of life should include the full spectrum of probable environments. The goals of this chapter are to synthesize diverse information about the inorganic geochemistry of submarine hydrothermal systems, assemble a description of the fundamental physical and chemical attributes of these systems, and consider the implications of high-temperature, fluid-driven processes for organic synthesis. Information about submarine hydrothermal systems comes from many directions. Measurements made directly on venting fluids provide useful, but remarkably limited, clues about processes operating at depth. The oceanic crust has been drilled to approximately 2.0 km depth providing many other pieces of information, but drilling technology has not allowed the bore holes and core samples to reach the maximum depths to which aqueous fluids circulate in oceanic crust. Such determinations rely on studies of pieces of deep oceanic crust uplifted by tectonic forces such as along the Southwest Indian Ridge, or more complete sections of oceanic crust called ophiolite sequences which are presently exposed on continents owing to tectonic emplacement. Much of what is thought to happen in submarine hydrothermal systems is inferred from studies of ophiolite sequences, and especially from the better-exposed ophiolites in Oman, Cyprus and North America. The focus of much that follows is on a few general features: pressure, temperature, oxidation states, fluid composition and mineral alteration, because these features will control whether organic synthesis can occur in hydrothermal systems.
Geologic Map of Kalaupapa Peninsula, Moloka‘i, Hawai‘i, USA
Okubo, Chris H.
2012-01-01
Kalaupapa Peninsula, along the northern coast of East Moloka‘i volcano, is a remarkably well-preserved example of rejuvenated-stage volcanism from a Hawaiian volcano. Mapping of lava flows, vents and other volcanic constructs reveals a diversity of landforms on this small monogenetic basaltic shield. The late-stage lava distributary system of this shield is dominated by a prominent lava channel and tube system emanating from the primary vent, Kauhakō crater. This system, along with several smaller examples, fed five prominent rootless vents downslope from Kauhakō. This map shows the subaerial part of this volcanic construct at 1:30,000 scale and encompasses an area of approximately 20.6 km2.
NASA Technical Reports Server (NTRS)
Wilson, Timmy R.; Beech, Geoffrey; Johnston, Ian
2009-01-01
The NESC Assessment Team reviewed a computer simulation of the LC-39 External Tank (ET) GH2 Vent Umbilical system developed by United Space Alliance (USA) for the Space Shuttle Program (SSP) and designated KSC Analytical Tool ID 451 (KSC AT-451). The team verified that the vent arm kinematics were correctly modeled, but noted that there were relevant system sensitivities. Also, the structural stiffness used in the math model varied somewhat from the analytic calculations. Results of the NESC assessment were communicated to the model developers.
NASA Astrophysics Data System (ADS)
Spina, L.; Taddeucci, J.; Cannata, A.; Sciotto, M.; Del Bello, E.; Scarlato, P.; Kueppers, U.; Andronico, D.; Privitera, E.; Ricci, T.; Pena-Fernandez, J.; Sesterhenn, J.; Dingwell, D. B.
2017-07-01
On 5 July 2014, an eruptive fissure opened on the eastern flank of Etna volcano (Italy) at 3.000 m a.s.l. Strombolian activity and lava effusion occurred simultaneously at two neighbouring vents. In the following weeks, eruptive activity led to the build-up of two cones, tens of meters high, here named Crater N and Crater S. To characterize the short-term (days) dynamics of this multi-vent system, we performed a multi-parametric investigation by means of a dense instrumental network. The experimental setup, deployed on July 15-16th at ca. 300 m from the eruption site, comprised two broadband seismometers and three microphones as well as high speed video and thermal cameras. Thermal analyses enabled us to characterize the style of eruptive activity at each vent. In particular, explosive activity at Crater N featured higher thermal amplitudes and a lower explosion frequency than at Crater S. Several episodes of switching between puffing and Strombolian activity were noted at Crater S through both visual observation and thermal data; oppositely, Crater N exhibited a quasi-periodic activity. The quantification of the eruptive style of each vent enabled us to infer the geometry of the eruptive system: a branched conduit, prone to rapid changes of gas flux accommodated at the most inclined conduit (i.e. Crater S). Accordingly, we were able to correctly interpret acoustic data and thereby extend the characterization of this two-vent system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CPMS) to measure and record the hourly average total regeneration stream mass flow during each carbon... during regeneration (except during the cooling cycle). (3) Use a CPMS to measure and record the hourly average temperature of the adsorption bed after regeneration (and within 15 minutes after completing any...
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CPMS) to measure and record the hourly average total regeneration stream mass flow during each carbon... during regeneration (except during the cooling cycle). (3) Use a CPMS to measure and record the hourly average temperature of the adsorption bed after regeneration (and within 15 minutes after completing any...
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CPMS) to measure and record the hourly average total regeneration stream mass flow during each carbon... during regeneration (except during the cooling cycle). (3) Use a CPMS to measure and record the hourly average temperature of the adsorption bed after regeneration (and within 15 minutes after completing any...
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CPMS) to measure and record the hourly average total regeneration stream mass flow during each carbon... during regeneration (except during the cooling cycle). (3) Use a CPMS to measure and record the hourly average temperature of the adsorption bed after regeneration (and within 15 minutes after completing any...
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CPMS) to measure and record the hourly average total regeneration stream mass flow during each carbon... during regeneration (except during the cooling cycle). (3) Use a CPMS to measure and record the hourly average temperature of the adsorption bed after regeneration (and within 15 minutes after completing any...
40 CFR 63.11396 - What are the standards and compliance requirements for new sources?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Modacrylic Fibers Production Area Sources Standards and Compliance Requirements § 63.11396 What are the... through a closed vent system to any combination of control devices meeting the requirements for process... (b)(1), (2), or (3) of this section for each fiber spinning line that uses a spin dope produced from...
40 CFR 63.11396 - What are the standards and compliance requirements for new sources?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Modacrylic Fibers Production Area Sources Standards and Compliance Requirements § 63.11396 What are the... through a closed vent system to any combination of control devices meeting the requirements for process... (b)(1), (2), or (3) of this section for each fiber spinning line that uses a spin dope produced from...
40 CFR 264.1087 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... of such devices include, but are not limited to, a car-seal or a lock-and-key configuration valve...) A boiler or industrial furnace burning hazardous waste for which the owner or operator has been... requirements of 40 CFR part 266, subpart H; or (E) A boiler or industrial furnace burning hazardous waste for...
NASA Astrophysics Data System (ADS)
Larson, B. I.; Houghton, J. L.; Lowell, R. P.; Farough, A.; Meile, C. D.
2015-08-01
Chemical gradients in the subsurface of mid-ocean ridge hydrothermal systems create an environment where minerals precipitate and dissolve and where chemosynthetic organisms thrive. However, owing to the lack of easy access to the subsurface, robust knowledge of the nature and extent of chemical transformations remains elusive. Here, we combine measurements of vent fluid chemistry with geochemical and transport modeling to give new insights into the under-sampled subsurface. Temperature-composition relationships from a geochemical mixing model are superimposed on the subsurface temperature distribution determined using a heat flow model to estimate the spatial distribution of fluid composition. We then estimate the distribution of Gibb's free energies of reaction beneath mid oceanic ridges and by combining flow simulations with speciation calculations estimate anhydrite deposition rates. Applied to vent endmembers observed at the fast spreading ridge at the East Pacific Rise, our results suggest that sealing times due to anhydrite formation are longer than the typical time between tectonic and magmatic events. The chemical composition of the neighboring low temperature flow indicates relatively uniform energetically favorable conditions for commonly inferred microbial processes such as methanogenesis, sulfate reduction and numerous oxidation reactions, suggesting that factors other than energy availability may control subsurface microbial biomass distribution. Thus, these model simulations complement fluid-sample datasets from surface venting and help infer the chemical distribution and transformations in subsurface flow.
Code of Federal Regulations, 2014 CFR
2014-07-01
... reduce the vent stream halogen atom mass emission rate to less than 0.45 kilogram per hour prior to a combustion control device in compliance with § 63.113(c)(2) of this subpart shall determine the halogen atom...
Code of Federal Regulations, 2011 CFR
2011-07-01
... reduce the vent stream halogen atom mass emission rate to less than 0.45 kilogram per hour prior to a combustion control device in compliance with § 63.113(c)(2) of this subpart shall determine the halogen atom...
Code of Federal Regulations, 2013 CFR
2013-07-01
... reduce the vent stream halogen atom mass emission rate to less than 0.45 kilogram per hour prior to a combustion control device in compliance with § 63.113(c)(2) of this subpart shall determine the halogen atom...
Code of Federal Regulations, 2012 CFR
2012-07-01
... reduce the vent stream halogen atom mass emission rate to less than 0.45 kilogram per hour prior to a combustion control device in compliance with § 63.113(c)(2) of this subpart shall determine the halogen atom...
LOX Tank Helium Removal for Propellant Scavenging
NASA Technical Reports Server (NTRS)
Chato, David J.
2009-01-01
System studies have shown a significant advantage to reusing the hydrogen and oxygen left in these tanks after landing on the Moon in fuel cells to generate power and water for surface systems. However in the current lander concepts, the helium used to pressurize the oxygen tank can substantially degrade fuel cell power and water output by covering the reacting surface with inert gas. This presentation documents an experimental investigation of methods to remove the helium pressurant while minimizing the amount of the oxygen lost. This investigation demonstrated that significant quantities of Helium (greater than 90% mole fraction) remain in the tank after draining. Although a single vent cycle reduced the helium quantity, large amounts of helium remained. Cyclic venting appeared to be more effective. Three vent cycles were sufficient to reduce the helium to small (less than 0.2%) quantities. Two vent cycles may be sufficient since once the tank has been brought up to pressure after the second vent cycle the helium concentration has been reduced to the less than 0.2% level. The re-pressurization process seemed to contribute to diluting helium. This is as expected since in order to raise the pressure liquid oxygen must be evaporated. Estimated liquid oxygen loss is on the order of 82 pounds (assuming the third vent cycle is not required).
Modeling of zero gravity venting: Studies of two-phase heat transfer under reduced gravity
NASA Technical Reports Server (NTRS)
Merte, H., Jr.
1986-01-01
The objective is to predict the pressure response of a saturated liquid-vapor system when undergoing a venting or depressurization process in zero gravity at low vent rates. An experimental investigation of the venting of cylindrical containers partially filled with initially saturated liquids was previously conducted under zero-gravity conditions and compared with an analytical model which incorporated the effect of interfacial mass transfer on the ullage pressure response during venting. A new model is presented to improve the estimation of the interfacial mass transfer. Duhammel's superposition integral is incorporated to approximate the transient temperature response of the interface, treating the liquid as a semi-infinite solid with conduction heat transfer. Account is also taken of the condensation taking place within the bulk of a saturated vapor as isentropic expansion takes place. Computational results are presented for the venting of R-11 from a given vessel and initial state for five different venting rates over a period of three seconds, and compared to prior NASA experiments. An improvement in the prediction of the final pressure takes place, but is still considerably below the measurements.
40 CFR 63.640 - Applicability and designation of affected source.
Code of Federal Regulations, 2014 CFR
2014-07-01
... reformer catalyst regeneration vents, and sulfur plant vents; and (5) Emission points routed to a fuel gas... required for refinery fuel gas systems or emission points routed to refinery fuel gas systems. (e) The... petroleum refining process unit that is subject to this subpart; (3) Units processing natural gas liquids...
40 CFR 63.640 - Applicability and designation of affected source.
Code of Federal Regulations, 2013 CFR
2013-07-01
... reformer catalyst regeneration vents, and sulfur plant vents; and (5) Emission points routed to a fuel gas... required for refinery fuel gas systems or emission points routed to refinery fuel gas systems. (e) The... petroleum refining process unit that is subject to this subpart; (3) Units processing natural gas liquids...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... practice standards? (a) By-product hydrogen streams and end box ventilation system vents. (1) For all by-product hydrogen streams and all end box ventilation system vents, if applicable, you must demonstrate...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... practice standards? (a) By-product hydrogen streams and end box ventilation system vents. (1) For all by-product hydrogen streams and all end box ventilation system vents, if applicable, you must demonstrate...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... practice standards? (a) By-product hydrogen streams and end box ventilation system vents. (1) For all by-product hydrogen streams and all end box ventilation system vents, if applicable, you must demonstrate...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... practice standards? (a) By-product hydrogen streams and end box ventilation system vents. (1) For all by-product hydrogen streams and all end box ventilation system vents, if applicable, you must demonstrate...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... practice standards? (a) By-product hydrogen streams and end box ventilation system vents. (1) For all by-product hydrogen streams and all end box ventilation system vents, if applicable, you must demonstrate...
24 CFR 3280.610 - Drainage systems.
Code of Federal Regulations, 2012 CFR
2012-04-01
... individually vented. (iii) A 3-inch minimum diameter piping shall be required for water closets. (f) Wet-vented... water seal trap (§ 3280.606(a)). (2) The drainage system shall be designed to provide an adequate... equipped with a water-tight cap or plug matching the drain outlet. The cap or plug shall be permanently...
24 CFR 3280.610 - Drainage systems.
Code of Federal Regulations, 2013 CFR
2013-04-01
... individually vented. (iii) A 3-inch minimum diameter piping shall be required for water closets. (f) Wet-vented... water seal trap (§ 3280.606(a)). (2) The drainage system shall be designed to provide an adequate... equipped with a water-tight cap or plug matching the drain outlet. The cap or plug shall be permanently...
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
DOE Office of Scientific and Technical Information (OSTI.GOV)
2016-02-01
This document addresses the use of passive vents as a source of outdoor air in multifamily buildings. The challenges associated with implementing passive vents and the factors affecting performance are outlined. A comprehensive design methodology and quantified performance metrics are provided. Two hypothetical design examples are provided to illustrate the process. This document is intended to be useful to designers, decision-makers, and contractors implementing passive ventilation strategies. It is also intended to be a resource for those responsible for setting high-performance building program requirements, especially pertaining to ventilation and outdoor air. To ensure good indoor air quality, a dedicated sourcemore » of outdoor air is an integral part of high-performance buildings. Presently, there is a lack of guidance pertaining to the design and installation of passive vents, resulting in poor system performance. This report details the criteria necessary for designing, constructing, and testing passive vent systems to enable them to provide consistent and reliable levels of ventilation air from outdoors.« less
Bus Vent Design Evolution for the Solar Dynamics Observatory
NASA Technical Reports Server (NTRS)
Woronowicz, Michael
2010-01-01
As a spacecraft undergoes ascent in a launch vehicle, its pressure environment transitions from one atmosphere to high vacuum in a matter of minutes. Venting of internal cavities is necessary to prevent the buildup of pressure differentials across cavity walls. Opposing the need to vent these volumes freely into space are thermal, optical, and electrostatic requirements for limiting or prohibiting the intrusion of unwanted energy into the same cavities. Bus vent design evolution is discussed for the Solar Dynamics Observatory. Design changes were influenced by a number of factors and concerns, such as contamination control, electrostatic discharge, changes in bus material, and driving fairing ascent pressure for a launch vehicle that was just entering service as this satellite project had gotten underway.
NASA Astrophysics Data System (ADS)
Merle, S. G.; Chadwick, W. W.; Embley, R. W.; Doucet, M.
2012-12-01
During a March 2010 expedition to NW Rota-1 submarine volcano in the Mariana arc a new EM122 multibeam sonar system on the R/V Kilo Moana was used to repeatedly image bubble plumes in the water column over the volcano. The EM122 (12 kHz) system collects seafloor bathymetry and backscatter data, as well as acoustic return water column data. Previous expeditions to NW Rota-1 have included seafloor mapping / CTD tow-yo surveys and remotely operated vehicle (ROV) dives in 2004, 2005, 2006 and 2009. Much of the focus has been on the one main eruptive vent, Brimstone, located on the south side of the summit at a depth of ~440m, which has been persistently active during all ROV visits. Extensive degassing of CO2 bubbles have been observed by the ROV during frequent eruptive bursts from the vent. Between expeditions in April 2009 and March 2010 a major eruption and landslide occurred at NW Rota-1. ROV dives in 2010 revealed that after the landslide the eruptive vent had been reorganized from a single site to a line of vents. Brimstone vent was still active, but 4 other new eruptive vents had also emerged in a NW/SE line below the summit extending ~100 m from the westernmost to easternmost vents. During the ROV dives, the eruptive vents were observed to turn on and off from day to day and hour to hour. Throughout the 2010 expedition numerous passes were made over the volcano summit to image the bubble plumes above the eruptive vents in the water column, in order to capture the variability of the plumes over time and to relate them to the eruptive output of the volcano. The mid-water sonar data set totals >95 hours of observations over a 12-day period. Generally, the ship drove repeatedly over the eruptive vents at a range of ship speeds (0.5-4 knots) and headings. In addition, some mid-water data was collected during three ROV dives when the ship was stationary over the vents. We used the FMMidwater software program (part of QPS Fledermaus) to visualize and analyze the data collected with this new mid-water technology. The data show that during some passes over the vent all 5 eruptive vents were contributing to the plume above the volcano, whereas on other passes only 1 vent was visible. However, it was common that multiple vents were active at any one time. The highest observed rise of a bubble plume in the water column came from the easternmost vent, with the main plume rising 415 meters from the vent to within 175 m of the surface. In some cases, wisps from the main plume rose to heights less than 100 m from the surface. This analysis shows that water column imaging multibeam sonar data can be used as a proxy to determine the level of eruptive activity above submarine volcanoes that have robust CO2 output. We plan to compare this data set to other data sets including hydrophone recordings, ADCP data and ROV visual observations.
Characterization of On-Orbit U.S. Lab Condensate Vacuum Venting
NASA Astrophysics Data System (ADS)
Schmidl, W. D.; Alred, J. A.; Mikatarian, R.; Soares, C.; Miles, E.
2002-01-01
The venting of liquid streams into a vacuum has been studied extensively for many years. An experiment was performed aboard the International Space Station (ISS) to video tape the U.S. Lab's condensate venting event with cameras located on the Space Station Remote Manipulator System (SSRMS). Images of the vent plume were acquired close to both the port and starboard vent nozzles. The imaging started with a wider view and then zoomed in closer before the shutdown phase of the vent event occurred. The objective of this experiment was to extend our understanding of the properties of venting liquids into space. Data from the video images were analyzed to obtain the approximate cone angle encompassing the core of the vent plume. The condensate vent plume was characterized as having three phases, a startup phase, a nominal phase, and a shutdown phase. The startup phase consisted of the initial period when the vent first started and the liquid first entered the heated line. The nominal phase was the period when the majority of the liquid was vented. The shutdown phase occurs close to the end of the vent event. The shutdown phase was further divided into two parts, the shutdown initial phase, and a later shutdown sputtering phase. The shutdown initial phase occurs when gas becomes entrained in the condensate liquid being vented. The sputtering phase occurred after the vent valve was closed, and the liquid/ice in the line was removed by continuing to heat the line to bake it out. It was determined that the ice particles were ejected at higher angles, but lower velocities, during the startup and shutdown phases. The number and velocities of ice particles ejected outside of the core region, during the startup, initial shutdown and shutdown sputtering phases were determined. The core of liquid ejected during the startup and shutdown phases was contained within a half cone angle of less than 60 degrees. The startup phase took approximately 36 seconds, the shutdown initial phase took approximately 22 seconds, and the shutdown sputtering phase took approximately 32 seconds. Results from the experiment were correlated with the Boeing ISS vent plume model.
9. DETAIL, ROOF VENT HOUSING. NOTE THE TUNNEL TO TEST ...
9. DETAIL, ROOF VENT HOUSING. NOTE THE TUNNEL TO TEST STAND 1-3 AT FAR LEFT, AND ITS MACHINE SHOP AT LEFT CENTER. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Instrumentation & Control Building, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA
40 CFR 63.1259 - Recordkeeping requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... required by § 63.1253(f)(2) and the pressure relief vent setting and the leak detection records specified... human health or the environment than if the storage tanks and process vents were controlled according to... guidance that the Administrator makes available for use or any other technically sound information or...
40 CFR 63.1425 - Process vent control requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards for Hazardous Air Pollutant Emissions for Polyether Polyols Production § 63.1425 Process vent... operators of all affected sources using epoxides in the production of polyether polyols are subject to the... (c) of this section only if epoxides are used in the production of polyether polyols and nonepoxide...
NASA Astrophysics Data System (ADS)
McDermott, J. M.; Seewald, J.; German, C. R.; Sylva, S. P.
2013-12-01
The generation of organic compounds in vent fluids has been of interest since the discovery of seafloor hydrothermal systems, due to implications for the sustenance of present-day microbial populations and their potential role in the origin of life on early Earth. Possible sources of organic compounds in hydrothermal systems include microbial production, thermogenic degradation of organic material, and abiotic synthesis. Abiotic organic synthesis reactions may occur during active circulation of seawater-derived fluids through the oceanic crust or within olivine-hosted fluid inclusions containing carbon-rich magmatic volatiles. H2-rich end-member fluids at the Von Damm vent field on the Mid-Cayman Rise, where fluid temperatures reach 226°C, provide an exciting opportunity to examine the extent of abiotic carbon transformations in a highly reducing system. Our results indicate multiple sources of carbon compounds in vent fluids at Von Damm. An ultramafic-influenced hydrothermal system located on the Mount Dent oceanic core complex at 2350 m depth, Von Damm vent fluids contain H2, CH4, and C2+ hydrocarbons in high abundance relative to basalt-hosted vent fields, and in similar abundance to other ultramafic-hosted systems, such as Rainbow and Lost City. The CO2 content and isotopic composition in end-member fluids are virtually identical to bottom seawater, suggesting that seawater DIC is unchanged during hydrothermal circulation of seawater-derived fluids. Accordingly, end-member CH4 that is present in slightly greater abundance than CO2 cannot be generated from reduction of aqueous CO2 during hydrothermal circulation. We postulate that CH4 and C2+ hydrocarbons that are abundantly present in Von Damm vent fluids reflect leaching of fluids from carbon- and H2-rich fluid inclusions hosted in plutonic rocks. Geochemical modeling of carbon speciation in the Von Damm fluids suggests that the relative abundances of CH4, C2+ hydrocarbons, and CO2 are consistent with thermodynamic equilibrium at higher temperatures and more reducing conditions than those observed in the Von Damm vent fluids. These findings are consistent with a scenario in which n-alkanes form abiotically within a high-H2, carbon-rich olivine-hosted fluid inclusion, and are subsequently liberated and transported to the seafloor during hydrothermal alteration of the lower crustal rocks exposed at the Mount Dent oceanic core complex. Mixed fluids at Von Damm show depletions in CO2 and H2, relative to conservative mixing. Multiple S isotope measurements indicate that the H2 sink cannot be attributed to sulfate reduction. Thermodynamic constraints indicate that high-H2 conditions support the active formation of formate via reduction of dissolved CO2 during hydrothermal circulation - a process that has also been described at the Lost City vent field - and could account for the concurrent depletions in CO2 and H2. The transformation of inorganic carbon to organic compounds via two distinct pathways in modern seafloor hydrothermal vents validates theoretical and experimental conceptual models regarding processes occurring in the crust and during hydrothermal circulation, and is relevant to supporting life in vent ecosystems.
Copley, J. T.; Marsh, L.; Glover, A. G.; Hühnerbach, V.; Nye, V. E.; Reid, W. D. K.; Sweeting, C. J.; Wigham, B. D.; Wiklund, H.
2016-01-01
The Southwest Indian Ridge is the longest section of very slow to ultraslow-spreading seafloor in the global mid-ocean ridge system, but the biogeography and ecology of its hydrothermal vent fauna are previously unknown. We collected 21 macro- and megafaunal taxa during the first Remotely Operated Vehicle dives to the Longqi vent field at 37° 47′S 49° 39′E, depth 2800 m. Six species are not yet known from other vents, while six other species are known from the Central Indian Ridge, and morphological and molecular analyses show that two further polychaete species are shared with vents beyond the Indian Ocean. Multivariate analysis of vent fauna across three oceans places Longqi in an Indian Ocean province of vent biogeography. Faunal zonation with increasing distance from vents is dominated by the gastropods Chrysomallon squamiferum and Gigantopelta aegis, mussel Bathymodiolus marisindicus, and Neolepas sp. stalked barnacle. Other taxa occur at lower abundance, in some cases contrasting with abundances at other vent fields, and δ13C and δ15N isotope values of species analysed from Longqi are similar to those of shared or related species elsewhere. This study provides baseline ecological observations prior to mineral exploration activities licensed at Longqi by the United Nations. PMID:27966649
Technologies for Refueling Spacecraft On-Orbit
NASA Technical Reports Server (NTRS)
Chato, David J.
2000-01-01
This paper discusses the current technologies for on-orbit refueling of spacecraft. The findings of 55 references are reviewed and summarized. Highlights include: (1) the Russian Progress system used by the International Space Station; (2) a flight demonstration of superfluid helium transfer; and (3) ground tests of large cryogenic systems. Key technologies discussed include vapor free liquid outflow, control of fluid inflow to prevent liquid venting, and quick disconnects for on-orbit mating of transfer lines.
Geophysical Signatures of cold vents on the northern Cascadia margin
NASA Astrophysics Data System (ADS)
Riedel, M.; Paull, C. K.; Spence, G.; Hyndman, R. D.; Caress, D. W.; Thomas, H.; Lundsten, E.; Ussler, W.; Schwalenberg, K.
2009-12-01
The accretionary prism of the northern Cascadia margin is a classic gas hydrate research area. Ocean Drilling Program Leg 146 and Integrated Ocean Drilling Program (IODP) Expedition 311 documented that gas hydrate is widely distributed across the margin. In recent years an increased research focus has been on cold vents, where methane gas is actively released. Two recent expeditions funded by the Monterey Bay Aquarium Research Institute (MBARI) were conducted in the area of IODP Sites U1327 and U1328. An autonomous underwater vehicle (AUV) was used to map the seafloor bathymetry followed by dives with the ROV Doc Ricketts for ground truth information of various seafloor morphological features identified. The two cruises revealed many new seafloor features indicative of methane venting that were previously unknown. Bullseye Vent (BV) has been extensively studied using seismic imaging, piston coring, heat-flow, controlled-source EM, and deep drilling. BV is seismically defined by a circular wipe-out zone but the new AUV data show that BV is rather an elongated depression. BV is associated with a shoaling in the BSR, but lacks evidence for the existence of an underlying fault in the previous data. Although a massive gas-hydrate plug was encountered within the top 40 mbsf in the IODP holes, the ROV observations only revealed some platy methane derived carbonate outcrops at the outer-most rim of the depressions, a few beds of Vesicomya clams, and no observed gas vents, which together do not indicate that BV is especially active now. Further northeast of BV, but along the same trend, active gas venting was found associated with seafloor blistering and bacterial mats suggesting that there is an underlying fault system providing a fluid flow conduit. The newly discovered vent area has few seismic line crossings; however the available seismic data surprisingly are not associated with wipe-out zones. Another prominent fault-related gas vent also was investigated during the two MBARI expeditions in 2009 (Spinnaker Vent, SV). Seismic profiles over SV show blanking and a slight uplift of the BSR that underlies the vent-area. The seafloor morphological expressions (trending over ~400 m) are similar to the elongated series of depressions seen at BV, but SV overall appears more active and younger due to the presence of widespread chemosynthetic communities, methane bubbling, massive outcrops of methane-derived carbonate as well as seafloor gas-hydrate bearing mounds. The seafloor features at SV all follow a fault trend that is clearly seen on the AUV bathymetry map, as also suggested by the earlier seismic data. Together the new MBARI expeditions and previous studies show that the area investigated on the N. Cascadia margin is dominated by fluid escape features. At least 12 cold vents (7 with bubble-plumes) are now identified within an area of ~10 km2 making a re-evaluation of the methane hydrate and associated underlying fluid-flow regimes an important focus of future studies.
Zero Gravity Cryogenic Vent System Concepts for Upper Stages
NASA Technical Reports Server (NTRS)
Flachbart, Robin H.; Holt, James B.; Hastings, Leon J.
2001-01-01
The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space, and would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray-bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray-bar system consists of a recirculation pump, a parallel flow concentric tube heat exchanger, and a spray-bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point, the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating boil-off losses.
An Analysis of Elliptic Grid Generation Techniques Using an Implicit Euler Solver.
1986-06-09
automatic determination of the control fu.nction, . elements of covariant metric tensor in the elliptic grid generation system , from the Cm = 1,2,3...computational fluid d’nan1-cs code. Tne code Inclues a tnree-dimensional current research is aimed primaril: at algebraic generation system based on transfinite...start the iterative solution of the f. ow, nea, transfer, and combustion proble:s. elliptic generation system . Tn13 feature also .:ven-.ts :.t be made
Status and Design Concepts for the Hydrogen On-Orbit Storage and Supply Experiment
NASA Technical Reports Server (NTRS)
Chato, David J.; VanDyke, Melissa; Batty, J. Clair; Schick, Scott
1998-01-01
This paper studies concepts for the Hydrogen On-Orbit Storage and Supply Experiment (HOSS). HOSS is a space flight experiment whose objectives are: Show stable gas supply for storage and direct gain solar-thermal thruster designs; and evaluate and compare low-g performance of active and passive pressure control via a thermodynamic vent system (TVS) suitable for solar-thermal upper stages. This paper shows that the necessary experimental equipment for HOSS can be accommodated in a small hydrogen dewar of 36 to 80 liter. Thermal designs for these dewars which meet the on-orbit storage requirements can be achieved. Furthermore ground hold insulation and shielding concepts are achieved which enable storing initially subcooled liquid hydrogen in these small dewars without venting in excess of 144 hours.
Functional Metagenomic Investigations of Microbial Communities in a Shallow-Sea Hydrothermal System
Tang, Kai; Liu, Keshao; Jiao, Nianzhi; Zhang, Yao; Chen, Chen-Tung Arthur
2013-01-01
Little is known about the functional capability of microbial communities in shallow-sea hydrothermal systems (water depth of <200 m). This study analyzed two high-throughput pyrosequencing metagenomic datasets from the vent and the surface water in the shallow-sea hydrothermal system offshore NE Taiwan. This system exhibited distinct geochemical parameters. Metagenomic data revealed that the vent and the surface water were predominated by Epsilonproteobacteria (Nautiliales-like organisms) and Gammaproteobacteria ( Thiomicrospira -like organisms), respectively. A significant difference in microbial carbon fixation and sulfur metabolism was found between the vent and the surface water. The chemoautotrophic microorganisms in the vent and in the surface water might possess the reverse tricarboxylic acid cycle and the Calvin−Bassham−Benson cycle for carbon fixation in response to carbon dioxide highly enriched in the environment, which is possibly fueled by geochemical energy with sulfur and hydrogen. Comparative analyses of metagenomes showed that the shallow-sea metagenomes contained some genes similar to those present in other extreme environments. This study may serve as a basis for deeply understanding the genetic network and functional capability of the microbial members of shallow-sea hydrothermal systems. PMID:23940820
NASA Astrophysics Data System (ADS)
Schaen, A. T.; Ding, K.; Seyfried, W. E.
2013-12-01
Developments in electrochemistry and material science have facilitated the construction of ceramic (YSZ) based chemical sensor systems that can be used to measure and monitor pH and redox in aqueous fluids at elevated temperatures and pressures. In recent years, these sensor systems have been deployed to acquire real-time and time series in-situ data for high-temperature hydrothermal vent fluids at the Main Endeavour Field (Juan de Fuca Ridge), 9oN (East Pacific Rise), and at the ultramafic-hosted Rainbow field (36oN, Mid-Atlantic Ridge). Here we review in-situ pH data measured at these sites and apply these data to estimate the pH of fluids ascending to the seafloor from hydrothermal alteration zones deeper in the crust. In general, in-situ pH measured at virtually all vent sites is well in excess of that measured shipboard owing to the effects of temperature on the distribution of aqueous species and the solubility of metal sulfides, especially Cu and Zn, originally dissolved in the vent fluids. In situ pH measurements determined at MEF (Sully vent) and EPR 9oN (P-vent) in 2005 and 2008 were 4.4 ×0.02 and 5.05×0.05, respectively. The temperature and pressure (seafloor) of the vent fluids at each of the respective sites were 356oC and 220 bar, and 380oC and 250 bar. Plotting these data with respect to fluid density reveals that the in-situ pH of each vent fluid is approximately 1.5 pH units below neutrality. The density-pH (in-situ) correlation, however, is important because it provides a means from which the vent fluids were derived. Using dissolved silica and chloride from fluid samples at the MEF (Sully) suggest T/P conditions of approximately 435oC, 380 bar, based on quartz-fluid and NaCl-H2O systems. At the fluid density calculated for these conditions, pH (in-situ) is predicted to be ~6.2. Attempts are presently underway to assess the effect of the calculated pH on metal sulfide and silicate (e.g., plagioclase, chlorite) solubility in comparison with constraints imposed by the full range of chemical components in the vent fluids sampled and analyzed in association with pH (in-situ) measurements. Since pH is a master variable in all geochemical systems, the novel approach proposed here may provide new insight on hydrothermal alteration processes at conditions difficult or impossible to assess by more traditional means, ultimately influencing hydrothermal fluid fluxes.
Detecting deep sea hydrothermal vents with a split-beam echosounder
NASA Astrophysics Data System (ADS)
Gray, L. M.; Jerram, K.
2016-12-01
In May 2016, the NOAA Office of Exploration and Research exploration vessel, Okeanos Explorer, conducted a remotely operated vehicle (ROV) dive on a series of active `black smoker' hydrothermal vents at 3,300 m depth in the western Pacific Ocean near the Mariana Trench. The ROV system traversed 800 m along the seafloor and detected three distinct vent sites. The vent chimneys ranged in heights from 5 m to 30 m above the seafloor and vent fluid temperatures were measured as high as 337 °C. Immediately following the ROV dive, the Okeanos Explorer mapped the vent field with an 18 kHz split-beam echosounder traditionally used for fishery research and a 30 kHz multibeam echosounder with midwater capability. Six passes were made over the field, transiting at 4-5 knots on various headings. There was a clear and repeatable signal in the split-beam echogram from the venting but less obvious indication in the multibeam data. `Black smokers' have traditionally been detected using repeat conductivity-temperature-depth (CTD) `tow-yo' casts. Our field observations suggest an alternative, and potentially more efficient, method of detecting hydrothermal vent plumes within the beamwidth of the split-beam echosounder to inform ROV dive plans. Methods previously applied for locating marine gas seeps on the seafloor with split-beam echosounders can be applied to estimate the hydrothermal vent positions in this dataset and compared to the recorded ROV positions at each site. Additionally, assuming relatively stable venting and ambient conditions, the ROV position and CTD data recorded from the vehicles can be used to better understand the observed midwater acoustic backscatter signatures of the hydrothermal vent plumes.
49 CFR 179.400-20 - Pressure relief devices.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., when the discharge is equal to twice the normal venting rate during transportation, with normal vacuum... communication to all areas of the insulation space. If a safety vent is a part of the system, it must be...
49 CFR 179.400-20 - Pressure relief devices.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., when the discharge is equal to twice the normal venting rate during transportation, with normal vacuum... communication to all areas of the insulation space. If a safety vent is a part of the system, it must be...
49 CFR 179.400-20 - Pressure relief devices.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., when the discharge is equal to twice the normal venting rate during transportation, with normal vacuum... communication to all areas of the insulation space. If a safety vent is a part of the system, it must be...
Acoustic measurement method of the volume flux of a seafloor hydrothermal plume
NASA Astrophysics Data System (ADS)
Xu, G.; Jackson, D. R.; Bemis, K. G.; Rona, P. A.
2011-12-01
Measuring fluxes (volume, chemical, heat, etc.) of the deep sea hydrothermal vents has been a crucial but challenging task faced by the scientific community since the discovery of the vent systems. However, the great depths and complexities of the hydrothermal vents make traditional sampling methods laborious and almost daunting missions. Furthermore, the samples, in most cases both sparse in space and sporadic in time, are hardly enough to provide a result with moderate uncertainty. In September 2010, our Cabled Observatory Vent Imaging Sonar System (COVIS, http://vizlab.rutgers.edu/AcoustImag/covis.html) was connected to the Neptune Canada underwater ocean observatory network (http://www.neptunecanada.ca) at the Main Endeavour vent field on the Endeavour segment of the Juan de Fuca Ridge. During the experiment, the COVIS system produced 3D images of the buoyant plume discharged from the vent complex Grotto by measuring the back-scattering intensity of the acoustic signal. Building on the methodology developed in our previous work, the vertical flow velocity of the plume is estimated from the Doppler shift of the acoustic signal using geometric correction to compensate for the ambient horizontal currents. A Gaussian distribution curve is fitted to the horizontal back-scattering intensity profile to determine the back-scattering intensity at the boundary of the plume. Such a boundary value is used as the threshold in a window function for separating the plume from background signal. Finally, the volume flux is obtained by integrating the resulting 2D vertical velocity profile over the horizontal cross-section of the plume. In this presentation, we discuss preliminary results from the COVIS experiment. In addition, several alternative approaches are applied to determination of the accuracy of the estimated plume vertical velocity in the absence of direct measurements. First, the results from our previous experiment (conducted in 2000 at the same vent complex using a similar methodology but a different sonar system) provide references to the consistency of the methodology. Second, the vertical flow rate measurement made in 2007 at an adjacent vent complex (Dante) using a different acoustic method (acoustic scintillation) can serve as a first order estimation of the plume vertical velocity. Third, another first order estimation can be obtained by combining the plume bending angle with the horizontal current measured by a current meter array deployed to the north of the vent field. Finally, statistical techniques are used to quantify the errors due to the ambient noises, inherent uncertainties of the methodology, and the fluctuation of the plume structure.
76 FR 66948 - Buy American Exceptions Under the American Recovery and Reinvestment Act of 2009
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-28
... Volume (VRV) heat pump system and vent limited gas regulators for the Lyndon B. Johnson Apartments... granted by HUD on the basis that the relevant manufactured goods, (a VRV heat pump system and vent limited gas regulators), are not produced in the U.S. in sufficient and reasonably available quantities or of...
Comparison of five methods for the estimation of methane production from vented in vitro systems.
Alvarez Hess, P S; Eckard, R J; Jacobs, J L; Hannah, M C; Moate, P J
2018-05-23
There are several methods for estimating methane production (MP) from feedstuffs in vented in vitro systems. One method (A; "gold standard") measures methane proportions in the incubation bottle's head space (HS) and in the vented gas collected in gas bags. Four other methods (B, C, D and E) measure methane proportion in a single gas sample from HS. Method B assumes the same methane proportion in the vented gas as in HS, method C assumes constant methane to carbon dioxide ratio, method D has been developed based on empirical data and method E assumes constant individual venting volumes. This study aimed to compare the MP predictions from these methods to that of the gold standard method under different incubation scenarios, to validate these methods based on their concordance with a gold standard method. Methods C, D and E had greater concordance (0.85, 0.88 and 0.81), lower root mean square error (RMSE) (0.80, 0.72 and 0.85) and lower mean bias (0.20, 0.35, -0.35) with the gold standard than did method B (concordance 0.67, RMSE 1.49 and mean bias 1.26). Methods D and E were simpler to perform than method C and method D was slightly more accurate than method E. Based on precision, accuracy and simplicity of implementation, it is recommended that, when method A cannot be used, methods D and E are preferred to estimate MP from vented in vitro systems. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Due to concerns surrounding its ozone depletion potential, there is a need for technologies to capture and destroy methyl bromide (CH3Br) emissions from post-harvest fumigations applied to control agricultural pests. Previously we described a system in which CH3Br fumes vented from fumigation chambe...
9 CFR 318.305 - Equipment and procedures for heat processing systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... review. (b) Divider plates. Whenever one or more divider plates are used between any two layers of... atmosphere. The manifold header shall not be controlled by a valve and shall be of a size such that the cross... discharging directly to the atmosphere. EC11SE91.017 Specifications (Figure 1): One, 1-inch (2.5 cm) vent for...
9 CFR 318.305 - Equipment and procedures for heat processing systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... review. (b) Divider plates. Whenever one or more divider plates are used between any two layers of... atmosphere. The manifold header shall not be controlled by a valve and shall be of a size such that the cross... discharging directly to the atmosphere. EC11SE91.017 Specifications (Figure 1): One, 1-inch (2.5 cm) vent for...
9 CFR 318.305 - Equipment and procedures for heat processing systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... review. (b) Divider plates. Whenever one or more divider plates are used between any two layers of... atmosphere. The manifold header shall not be controlled by a valve and shall be of a size such that the cross... discharging directly to the atmosphere. EC11SE91.017 Specifications (Figure 1): One, 1-inch (2.5 cm) vent for...
Code of Federal Regulations, 2010 CFR
2010-10-01
... transport, by air— (1) Vented Type B(M) packages, packages which require external cooling by an ancillary cooling system or packages subject to operational controls during transport; or (2) Liquid pyrophoric... transport index in excess of the limits specified in § 173.441(a) of this subchapter may not be transported...
1983-08-01
Proc. 2nd Congress National de flabilite, Perros -Guirec, Sept. 17-20, 1974, pp. 639-653. Published by CNET, Lannion (France). 53. Love, A. E. H., A...96. C. Rosiaux, Fiabilite des allumeurs determinee a partir des ventes-echanges, Proc. 2nd Congres National de fiabilite, Perros Guirec, Sept. 17-20
40 CFR 264.1087 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
...), (c)(1)(ii), or (c)(1)(iii) of this section, as applicable, shall not exceed 240 hours per year. (ii... paragraphs (c)(1)(i), (c)(1)(ii), or (c)(1)(iii) of this section, as applicable, shall not exceed 240 hours... either a performance test as specified in paragraph (c)(5)(iii) of this section or a design analysis as...
40 CFR 265.1033 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... established as a requirement of § 265.1035(b)(4)(iii)(F). (h) An owner or operator using a carbon adsorption..., as determined by the methods specified in paragraph (f)(2)(iii) of this section. (3) A flare shall be... (60 ft/s), except as provided in paragraphs (d)(4) (ii) and (iii) of this section. (ii) A steam...
40 CFR 264.1087 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
...), (c)(1)(ii), or (c)(1)(iii) of this section, as applicable, shall not exceed 240 hours per year. (ii... paragraphs (c)(1)(i), (c)(1)(ii), or (c)(1)(iii) of this section, as applicable, shall not exceed 240 hours... either a performance test as specified in paragraph (c)(5)(iii) of this section or a design analysis as...
40 CFR 265.1033 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... established as a requirement of § 265.1035(b)(4)(iii)(F). (h) An owner or operator using a carbon adsorption..., as determined by the methods specified in paragraph (f)(2)(iii) of this section. (3) A flare shall be... (60 ft/s), except as provided in paragraphs (d)(4) (ii) and (iii) of this section. (ii) A steam...
40 CFR 264.1087 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
...), (c)(1)(ii), or (c)(1)(iii) of this section, as applicable, shall not exceed 240 hours per year. (ii... paragraphs (c)(1)(i), (c)(1)(ii), or (c)(1)(iii) of this section, as applicable, shall not exceed 240 hours... either a performance test as specified in paragraph (c)(5)(iii) of this section or a design analysis as...
40 CFR 265.1033 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... established as a requirement of § 265.1035(b)(4)(iii)(F). (h) An owner or operator using a carbon adsorption..., as determined by the methods specified in paragraph (f)(2)(iii) of this section. (3) A flare shall be... (60 ft/s), except as provided in paragraphs (d)(4) (ii) and (iii) of this section. (ii) A steam...
40 CFR 265.1088 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... removing the lock. Examples of such devices include, but are not limited to, a car-seal or a lock-and-key... furnace burning hazardous waste for which the owner or operator has been issued a final permit under 40... 266, subpart H; or (E) A boiler or industrial furnace burning hazardous waste for which the owner or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... National Emission Standards for Hazardous Air Pollutant Emissions for Polyether Polyols Production § 63... percent reduction may be measured as total epoxide, total organic HAP, or as TOC minus methane and ethane... TOC (minus methane and ethane) concentrations in all process vent streams and primary and secondary...
Code of Federal Regulations, 2012 CFR
2012-07-01
... National Emission Standards for Hazardous Air Pollutant Emissions for Polyether Polyols Production § 63... percent reduction may be measured as total epoxide, total organic HAP, or as TOC minus methane and ethane... TOC (minus methane and ethane) concentrations in all process vent streams and primary and secondary...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Service Valve 1 6.42 Connector 5.71 Open-Ended Line 11.27 Pressure Relief Valve 2.01 Meter 2.93 Population... Pneumatic Device Vents 2 18.20 Intermittent Bleed Pneumatic Device Vents 2 2.35 1 Valves include control...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Service Valve 1 6.42 Connector 5.71 Open-Ended Line 11.27 Pressure Relief Valve 2.01 Meter 2.93 Population... Pneumatic Device Vents 2 18.20 Intermittent Bleed Pneumatic Device Vents 2 2.35 1 Valves include control...
Two Vent Fields Discovered at the Ultraslow Spreading Arctic Ridge System
NASA Astrophysics Data System (ADS)
Pedersen, R. B.; Thorseth, I. H.; Hellevang, B.; Schultz, A.; Taylor, P.; Knudsen, H. P.; Steinsbu, B. O.
2005-12-01
Two high-temperature vent fields were discovered at the Mohns Ridge during an expedition with the Norwegian research vessel "G.O. Sars" in July 2005. Both vent fields are located within the southernmost segment of the Mohns Ridge approximately 50 km north of the West Jan Mayen Fracture Zone. Water depths along this segment range from 3800 meters close to the fracture zone to ~500 meters at the segment centre where the vent fields are located. The largest field - named "Gallionella Garden" - is situated within a rift graben where high- and low-temperature venting occurs along ridge-parallel normal faults and fissures. Presently we have documented high- and low-temperature venting along more then 2 km of the fault and fissure system in the area. The high-temperature venting takes place at around 550 mbsl at the base of a 100 meter high fault wall and was traced ~500 meters along strike. The field consists of at least 10 major vent sites, each composed of multiple chimneys that are up to 5-10 meters tall. There are also large areas of diffuse flow. The temperature of the vent fluids was measured to be above 260°C at a chimney orifice. This is at the boiling point of seawater at these water depths, and gas bubbling was observed at several of the vent sites. A sample of the top of a chimney consists of anhydrite, barite, sphalerite and pyrite. Outside the high-temperature vent area mounds of ferric iron are abundant. Such deposits have presently been traced along ~2 km of the faults and fissure system in the area. The deposits are predominantly made up of branching and twisted stalks comparable to those formed by the iron oxidizing bacteria Gallionella ferruginea showing that the precipitation is mediated by microbial activity. The temperatures below the upper crust of a mound were measured to be one degree above the ambient water temperature. The Fe-oxyhydroxides show Nd-isotope compositions similar to the basaltic crust and Sr-isotope compositions close to that of seawater, and may have formed from fluids composed of 90 percent seawater and 10 percent of an end-member hydrothermal fluid. Nd-concentrations suggest Fe-precipitate/fluid ratio of one to a million (ie. that 1 kg of Fe-deposits scavenged neodymium from one million litres of fluids). A second vent field was discovered 5 km southwest of "Gallionella Garden" at ~700 mbsl. The "Soria Moria" field is located at a volcanic ridge composed of recent lava flows and is about 100 meters across. The field consists of numerous chimneys emitting buoyant white smoker fluids, as well as irregular shaped mounds with flange structures discharging fluids of higher density then the ambient waters. White bacterial mats cover the seafloor and chimneys at both fields, and shrimp, sea spiders and colonies of sea anemones, crinoids and hydroids are associated with the vent fields. The hydrothermal plumes were detected acoustically using the exceptionally sensitive scientific echo sounders on "G.O.Sars". The acoustic backscatters images show that the hydrothermal plume above "Gallionella Garden" perturb the upper hydrographical layers, implying that this shallow vent field may "fertilize" the productive hydrographical layers in the area.