  1. Stack Flow Rate Changes and the ANSI/N13.1-1999 Qualification Criteria: Application to the Hanford Canister Storage Building Stack

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flaherty, Julia E.; Glissmeyer, John A.

    2016-02-29

    The Canister Storage Building (CSB), located in the 200-East Area of the Hanford Site, is a 42,000 square foot facility used to store spent nuclear fuel from past activities at the Hanford Site. Because the facility has the potential to emit radionuclides into the environment, its ventilation exhaust stack has been equipped with an air monitoring system. Subpart H of the National Emissions Standards for Hazardous Air Pollutants requires that a sampling probe be located in the exhaust stack in accordance with criteria established by the American National Standards Institute/Health Physics Society Standard N13.1-1999, Sampling and Monitoring Releases of Airbornemore » Radioactive Substances from the Stack and Ducts of Nuclear Facilities.« less

  2. The Design of Exhaust Systems and Discharge Stacks [With Comments].

    ERIC Educational Resources Information Center

    Clarke, John H.

    1963-01-01

    An important part of ventilating for safety consists of providing the necessary exhaust systems to remove building contaminants safely. Further, the effluent must be cleaned within practical limits by means of filters, collectors, and scrubbers. Where recirculation is not safe or feasible, the effluent must be discharged to the outside in a manner…

  3. Physical Sciences Laboratory 1 Rooftop Stack Mixing Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flaherty, Julia E.; Antonio, Ernest J.

    To address concerns about worker exposures on the Physical Science Laboratory (PSL) rooftop, a tracer study was conducted to measure gaseous tracer concentrations downwind of six stacks on the southern half of the PSL building (PSL-1). These concerns were raised, in part, due to the non-standard configuration of the stacks on this building. Five of the six stacks were only about 8 feet tall, with one shorter stack that was essentially level with the roof deck. These stacks were reconfigured in August 2016, and these exhaust points on PSL-1 are now 18 feet tall. This report describes the objectives ofmore » the tracer tests performed on PSL-1, provides an overview of how the tests were executed, and presents results of the tests. The tests on the PSL rooftop were a follow-on project from a similar study performed on the LSL-II ventilation exhaust (Flaherty and Antonio, 2016).« less

  4. Life Sciences Laboratory 2 Fan Exhaust Mixing Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flaherty, Julia E.; Antonio, Ernest J.

    An SF 6 tracer release was performed in the LSL-II ventilation stack over the weekend of March 5, 2016. The primary purpose of this study was to experimentally determine the gaseous concentration of material from a fume hood to the fan outlet, as well as at typical worker locations, to gain an understanding of potential worker exposures impacts. Five different fan operating configurations were utilized to ensure that the full spectrum of historical operating configurations was addressed. Some summary points from this study include: •Relatively high concentrations were observed within the stack area. –Between 50 and 100% of the exhaustmore » concentration may be observed within the stack. •Background concentrations were observed outside the stack area. –Workers outside the stack itself, but on the roof, are unlikely to be impacted by the exhaust. •Elevated concentrations on the order of 25% of the exhaust concentrations were observed within the Penthouse. •Transport time from a laboratory fume hood to the exhaust fan is within one to two minutes. •Penthouse concentrations climb from background levels to steady state over 15+ minutes. •Wind speed and wind direction did not play a significant role in the test outcomes. –A slight bias in the concentration distribution may be discernable based on wind speed and direction. •When both fans are operating, material from fume hoods on the east side preferentially flow through the east fan, while material from fume hoods on the west side preferentially flow through the west fan. This effectively doubles the concentration at that fan. This mixing study will inform other study components to develop a more complete picture of the worker potential exposure from LSL-II Rooftop activities. Estimating the mean concentration in the stack from chemical inventories and fume hood emissions for both current and historical laboratory activities is a separate effort. These estimates of mean ventilation concentrations will utilize this mixing study to estimate the potential exposure to workers working in and around the LSL-II stack.« less

  5. [Appropriate dust control measures for jade carving operations].

    PubMed

    Liu, Jiang; Wang, Qiushui; Liu, Guangquan

    2002-12-01

    To provide the appropriate dust control measures for jade carving operations. Dust concentrations in the workplace were measured according to GB/T 5748-85. Ventilation system of dust control were measured according to GB/T 16157-1996. Dust particle size distributions for different sources and particle size fraction collecting efficiencies of the dust collectors were measured with WY-1 in-stack 7 stage cascade impactors. On the basis of adopting wet process in the carving operations, local exhaust ventilation system for dust control was installed, which included: the special designed slot exhaust hoods with hood face velocity of 2.5 m/s and exhaust volume of 600 m3/h. The pipe sizes were determined according to the air volume passing through the pipe and the reasonable air velocities. Impinging scrubber or bag filter dust collector were selected to treat the dust laden air from the local exhaust ventilation system, which gave a total collecting efficiency of 97% for impinging scrubber and 98% for bag filter; The type of fan and its size were selected according to the total air volume of the ventilation system and maximum total pressure needed for the longest pipe line plus the pressure drop of the dust collector. Practical application showed that, after installation and use of the appropriate dust control measures, the dust concentrations in the workplaces could meet or nearly meet the national hygienic standard and the dust laden air at the local exhaust ventilation system could meet the national emission standard.

  6. Mercury Dispersion Modeling And Purge Ventilation Stack Height Determination For Tank 40H

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rivera-Giboyeaux, A.

    2017-05-19

    The SRNL Atmospheric Technologies Group performed an analysis for mercury emissions from H-Tank Farm - Tank 40 ventilation system exhaust in order to assess whether the Short Term Exposure Limit (STEL), or Threshold Limit Value (TLV) levels for mercury will be exceeded during bulk sludge slurry mixing and sludge removal operations. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the main dispersion modelling tool for this analysis. The results indicated that a 45-foot stack is sufficient to raise the plume centerline from the Tank 40 release to prevent mercury exposure problems for any of the stackmore » discharge scenarios provided. However, a 42-foot stack at Tank 40 is sufficient to prevent mercury exposure concerns in all emission scenarios except the 50 mg/m 3 release. At a 42-foot stack height, values exceeding the exposure standards are only measured on receptors located above 34 feet.« less

  7. 33 CFR 183.630 - Standards for natural ventilation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... boat achieved by having: (1) A supply opening or duct from the atmosphere or from a ventilated compartment or from a compartment that is open to the atmosphere; and (2) An exhaust opening into another ventilated compartment or an exhaust duct to the atmosphere. (b) Each exhaust opening or exhaust duct must...

  8. 33 CFR 183.630 - Standards for natural ventilation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... boat achieved by having: (1) A supply opening or duct from the atmosphere or from a ventilated compartment or from a compartment that is open to the atmosphere; and (2) An exhaust opening into another ventilated compartment or an exhaust duct to the atmosphere. (b) Each exhaust opening or exhaust duct must...

  9. 33 CFR 183.630 - Standards for natural ventilation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... boat achieved by having: (1) A supply opening or duct from the atmosphere or from a ventilated compartment or from a compartment that is open to the atmosphere; and (2) An exhaust opening into another ventilated compartment or an exhaust duct to the atmosphere. (b) Each exhaust opening or exhaust duct must...

  10. 46 CFR 111.33-9 - Ventilation exhaust.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-9 Ventilation exhaust. The exhaust of each forced-air semiconductor rectifier system must: (a) Terminate in a location other than a hazardous location...

  11. Modular fuel-cell stack assembly

    DOEpatents

    Patel, Pinakin

    2010-07-13

    A fuel cell assembly having a plurality of fuel cells arranged in a stack. An end plate assembly abuts the fuel cell at an end of said stack. The end plate assembly has an inlet area adapted to receive an exhaust gas from the stack, an outlet area and a passage connecting the inlet area and outlet area and adapted to carry the exhaust gas received at the inlet area from the inlet area to the outlet area. A further end plate assembly abuts the fuel cell at a further opposing end of the stack. The further end plate assembly has a further inlet area adapted to receive a further exhaust gas from the stack, a further outlet area and a further passage connecting the further inlet area and further outlet area and adapted to carry the further exhaust gas received at the further inlet area from the further inlet area to the further outlet area.

  12. 14 CFR 25.1121 - General.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... could be subjected to high temperatures from exhaust system parts, must be fireproof. All exhaust system... ventilated to prevent points of excessively high temperature. (g) Each exhaust shroud must be ventilated or insulated to avoid, during normal operation, a temperature high enough to ignite any flammable fluids or...

  13. 14 CFR 25.1121 - General.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... could be subjected to high temperatures from exhaust system parts, must be fireproof. All exhaust system... ventilated to prevent points of excessively high temperature. (g) Each exhaust shroud must be ventilated or insulated to avoid, during normal operation, a temperature high enough to ignite any flammable fluids or...

  14. 14 CFR 29.1121 - General.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... to high temperatures from exhaust system parts, must be fireproof. Each exhaust system component must... ventilated to prevent points of excessively high temperature. (g) Each exhaust shroud must be ventilated or insulated to avoid, during normal operation, a temperature high enough to ignite any flammable fluids or...

  15. 14 CFR 25.1121 - General.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... could be subjected to high temperatures from exhaust system parts, must be fireproof. All exhaust system... ventilated to prevent points of excessively high temperature. (g) Each exhaust shroud must be ventilated or insulated to avoid, during normal operation, a temperature high enough to ignite any flammable fluids or...

  16. 14 CFR 25.1121 - General.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... could be subjected to high temperatures from exhaust system parts, must be fireproof. All exhaust system... ventilated to prevent points of excessively high temperature. (g) Each exhaust shroud must be ventilated or insulated to avoid, during normal operation, a temperature high enough to ignite any flammable fluids or...

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S.; Berger, D.; Zuluaga, M.

    In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the "fresh" air is coming from is gaining significance as air-tightness standards for enclosures become more stringent. CARB researchers have found that most new high performance, multifamily housing in the Northeast use one of four strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unitmore » HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. Product performance data are based on laboratory tests, but there is no guarantee that those conditions will exist consistently in the finished building. In this research project, CARB evaluated the four ventilation strategies in the field to validate system performance.« less

  18. Particulate matter in animal rooms housing mice in microisolation caging.

    PubMed

    Langham, Gregory L; Hoyt, Robert F; Johnson, Thomas E

    2006-11-01

    Reactions to allergens created by laboratory animals are among the most frequently encountered occupational illnesses associated with research animals. Personnel are exposed to these allergens through airborne particulate matter. Although the use of microisolation caging systems can reduce particulate matter concentrations in rooms housing mice, the operating parameters of ventilated caging systems vary extensively. We compared room air in mouse rooms containing 5 different types of caging: 1) individually ventilated caging under positive pressure with filtered intake air and exhaust air returned to the room (VCR+), 2) individually ventilated caging under negative pressure with exhaust air returned to the room (VCR-), 3) individually ventilated caging under positive pressure with exhaust air returned to the heating, ventilation, and air-conditioning (HVAC) system, 4) individually ventilated caging under negative pressure with exhaust air returned to the HVAC system, and 5) static microisolation cages. We found that rooms under VCR conditions had fewer large particles than did those under other conditions, but the numbers of 0.3 microm particles did not differ significantly among systems. Static, positive or negative pressure applied to caging units as well as route of air exhaust were found to have little influence on the total number of particles in the atmosphere. Therefore, considering the heat load, odor, and overall particulate concentration in the room, placing individually ventilated caging under negative pressure with exhaust air returned to the HVAC system appears to be the optimal overall choice when using microisolation housing for rodents.

  19. Sampling for Air Chemical Emissions from the Life Sciences Laboratory II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ballinger, Marcel Y.; Lindberg, Michael J.

    Sampling for air chemical emissions from the Life Science Laboratory II (LSL-II) ventilation stack was performed in an effort to determine potential exposure of maintenance staff to laboratory exhaust on the building roof. The concern about worker exposure was raised in December 2015 and several activities were performed to assist in estimating exposure concentrations. Data quality objectives were developed to determine the need for and scope and parameters of a sampling campaign to measure chemical emissions from research and development activities to the outside air. The activities provided data on temporal variation of air chemical concentrations and a basis formore » evaluating calculated emissions. Sampling for air chemical emissions was performed in the LSL-II ventilation stack over the 6-week period from July 26 to September 1, 2016. A total of 12 sampling events were carried out using 16 sample media. Resulting analysis provided concentration data on 49 analytes. All results were below occupational exposure limits and most results were below detection limits. When compared to calculated emissions, only 5 of the 49 chemicals had measured concentrations greater than predicted. This sampling effort will inform other study components to develop a more complete picture of a worker’s potential exposure from LSL-II rooftop activities. Mixing studies were conducted to inform spatial variation in concentrations at other rooftop locations and can be used in conjunction with these results to provide temporal variations in concentrations for estimating the potential exposure to workers working in and around the LSL-II stack.« less

  20. Flow Characteristics of a Multiple Nozzle Exhaust Gas Eductor System.

    DTIC Science & Technology

    1981-03-01

    these exhaust gases are a temperatures significantly above those of conventionally powered ships. A few of the problems caused by these high temperatures ...systems designed for marine gas turbine applications must substantially cool exhaust gases , present an exterior stack surface temperature which will not...stack in. H 02 R - Gas constant for air, 53.34 ft-lbf/Ibm-R s - Entropy, Btu/Ibm-R S - Primary dimension of mixing stack T - Absolute temperature , R

  1. Technology Solutions Case Study: Evaluation of Ventilation Strategies in New Construction Multifamily Buildings, New York, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-09-01

    In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the "fresh" air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the "normal leakage paths through the building envelope" disappear. Consortium for Advanced Residential Buildings researchers have found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust withmore » ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. This research effort included several weeks of building pressure monitoring to validate system performance of the different strategies for providing make-up air to apartments.« less

  2. The use of chilled condensers for the recovery of perfluorocarbon liquid in an experimental model of perfluorocarbon vapour loss during neonatal partial liquid ventilation

    PubMed Central

    Dunster, Kimble R; Davies, Mark W; Fraser, John F

    2007-01-01

    Background Perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be prevented from entering the atmosphere and recovered for potential reuse. This study aimed to determine how much PFC liquid could be recovered using a conventional humidified neonatal ventilator with chilled condensers in place of the usual expiratory ventilator circuit and whether PFC liquid could be recovered when using the chilled condensers at the ventilator exhaust outlet. Methods Using a model lung, perfluorocarbon vapour loss during humidified partial liquid ventilation of a 3.5 kg infant was approximated. For each test 30 mL of FC-77 was infused into the model lung. Condensers were placed in the expiratory limb of the ventilator circuit and the amounts of PFC (FC-77) and water recovered were measured five times. This was repeated with the condensers placed at the ventilator exhaust outlet. Results When the condensers were used as the expiratory limb, the mean (± SD) volume of FC77 recovered was 16.4 mL (± 0.18 mL). When the condensers were connected to the ventilator exhaust outlet the mean (± SD) volume of FC-77 recovered was 7.6 mL (± 1.14 mL). The volume of FC-77 recovered was significantly higher when the condenser was used as an expiratory limb. Conclusion Using two series connected condensers in the ventilator expiratory line 55% of PFC liquid (FC-77) can be recovered during partial liquid ventilation without altering the function of the of the ventilator circuit. This volume of PFC recovered was just over twice that recovered with the condensers connected to the ventilator exhaust outlet. PMID:17537270

  3. Natural ventilation of buildings: opposing wind and buoyancy

    NASA Astrophysics Data System (ADS)

    Linden, Paul; Hunt, Gary

    1998-11-01

    The use of natural ventilation in buildings is an attractive way to reduce energy usage thereby reducing costs and CO2 emissions. Generally, it is necessary to remove excess heat from a building and the designer can use the buoyancy forces associated with the above ambient temperatures within the building to drive a flow - 'stack' ventilation. The most efficient mode is displacement ventilation where warm air accumulates near the top of the building and flows out through upper level vents and cooler air flows in at lower levels. Ventilation will also be driven between these lower and upper openings by the wind. We report on laboratory modeling and theory which investigates the effects of an opposing wind on stack ventilation driven by a constant source of heat within a space under displacement ventilation. We show that there is a critical wind speed, expressed in dimensionless terms as a critical Froude number, above which displacement ventilation is replaced by (less efficient) mixing ventilation with reversed flow. Below this critical speed, displacement ventilation, in which the interior has a two-layer stratification, is maintained. The criterion for the change in ventilation mode is derived from general considerations of mixing efficiencies in stratified flows. We conclude that even when wind effects might appear to be dominant, the inhibition of mixing by the stable stratification within the space ensures that stack ventilation can operate over a wide range of apparently adverse conditions.

  4. National Weatherization Assistance Program Impact Evaluation: Impact of Exhaust-Only Ventilation on Radon and Indoor Humidity - A Field Investigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pigg, Scott

    2014-09-01

    The study described here sought to assess the impact of exhaust-only ventilation on indoor radon and humidity in single-family homes that had been treated by the Weatherization Assistance Program (WAP).

  5. Generator stator core vent duct spacer posts

    DOEpatents

    Griffith, John Wesley; Tong, Wei

    2003-06-24

    Generator stator cores are constructed by stacking many layers of magnetic laminations. Ventilation ducts may be inserted between these layers by inserting spacers into the core stack. The ventilation ducts allow for the passage of cooling gas through the core during operation. The spacers or spacer posts are positioned between groups of the magnetic laminations to define the ventilation ducts. The spacer posts are secured with longitudinal axes thereof substantially parallel to the core axis. With this structure, core tightness can be assured while maximizing ventilation duct cross section for gas flow and minimizing magnetic loss in the spacers.

  6. Exhaust-stack nozzle area and shape for individual cylinder exhaust-gas jet-propulsion system

    NASA Technical Reports Server (NTRS)

    Pinkel, Benjamin; Turner, Richard; Voss, Fred; Humble, Leroy V

    1943-01-01

    This report presents the results of an investigation conducted on the effect of exhaust-stack nozzle area, shape, and length on engine power, jet thrust, and gain in net thrust (engine propeller plus jet). Single-cylinder engine data were obtained using three straight stacks 25, 44, and 108 inches in length; an S-shaped stack, a 90 degree bend, a 180 degree bend, and a short straight stack having a closed branch faired into it. Each stack was fitted with nozzles varying in exit area from 0.91 square inch to the unrestricted area of the stack of 4.20 square inches. The engine was generally operated over a range of engine speeds from 1300 to 2100 r.p.m, inlet-manifold pressures from 22 to 30 inches of mercury absolute, and a fuel-air ratio of 0.08. The loss in engine power, the jet thrust, and the gain in net thrust are correlated in terms of several simple parameters. An example is given for determining the optimum nozzle area and the overall net thrust.

  7. 46 CFR 111.33-9 - Ventilation exhaust.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Ventilation exhaust. 111.33-9 Section 111.33-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL... under Subpart 111.105 of this part; and (b) Not impinge upon any other electric device. ...

  8. 46 CFR 111.33-9 - Ventilation exhaust.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Ventilation exhaust. 111.33-9 Section 111.33-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL... under Subpart 111.105 of this part; and (b) Not impinge upon any other electric device. ...

  9. 46 CFR 111.33-9 - Ventilation exhaust.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Ventilation exhaust. 111.33-9 Section 111.33-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL... under Subpart 111.105 of this part; and (b) Not impinge upon any other electric device. ...

  10. 46 CFR 111.33-9 - Ventilation exhaust.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Ventilation exhaust. 111.33-9 Section 111.33-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL... under Subpart 111.105 of this part; and (b) Not impinge upon any other electric device. ...

  11. Building America Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts, Tyler, Texas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ?Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, andmore » filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy.« less

  12. 27. Historic view of Building 202 exhaust scrubber stack, July ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. Historic view of Building 202 exhaust scrubber stack, July 31, 1957. On file at NASA Plumbrook Research Center, Sandusky, Ohio. NASA GRC photo number C-45650. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  13. 29 CFR 1926.57 - Ventilation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... exhaust ventilation when used as described in (a) shall be designed to prevent dispersion into the air of... shall be so designed that dusts, fumes, mists, vapors, or gases are not drawn through the work area of employees. (c) Design and operation. Exhaust fans, jets, ducts, hoods, separators, and all necessary...

  14. Occupational exposure to nitrous oxide - the role of scavenging and ventilation systems in reducing the exposure level in operating rooms.

    PubMed

    Krajewski, Wojciech; Kucharska, Malgorzata; Wesolowski, Wiktor; Stetkiewicz, Jan; Wronska-Nofer, Teresa

    2007-03-01

    The aim of this study was to assess the level of occupational exposure to nitrous oxide (N(2)O) in operating rooms (ORs), as related to different ventilation and scavenging systems used to remove waste anaesthetic gases from the work environment. The monitoring of N(2)O in the air covered 35 ORs in 10 hospitals equipped with different systems for ventilation and anaesthetic scavenging. The examined systems included: natural ventilation with supplementary fresh air provided by a pressure ventilation system (up to 6 air changes/h); pressure and exhaust ventilation systems equipped with ventilation units supplying fresh air to and discharging contaminated air outside the working area (more than 10 air changes/h); complete air-conditioning system with laminar air flow (more than 15 air changes/h). The measurements were carried out during surgical procedures (general anaesthesia induced intravenously and maintained with inhaled N(2)O and sevofluran delivered through cuffed endotracheal tubes) with connected or disconnected air scavenging. Air was collected from the breathing zone of operating personnel continuously through the whole time of anaesthesia to Tedlar((R)) bags, and N(2)O concentrations in air samples were analyzed by adsorption gas chromatography/mass spectrometry. N(2)O levels in excess of the occupational exposure limit (OEL) value of 180mg/m(3) were registered in all ORs equipped with ventilation systems alone. The OEL value was exceeded several times in rooms with natural ventilation plus supplementary pressure ventilations and twice or less in those with pressure/exhaust ventilation systems or air conditioning. N(2)O levels below or within the OEL value were observed in rooms where the system of air conditioning or pressure/exhaust ventilation was combined with scavenging systems. Systems combining natural/pressure ventilation with scavenging were inadequate to maintain N(2)O concentration below the OEL value. Air conditioning and an efficient pressure/exhaust ventilation (above 12 air exchanges/h) together with efficient active scavenging systems are sufficient to sustain N(2)O exposure in ORs at levels below or within the OEL value of 180mg/m(3).

  15. Burnout control at the Albright coal-waste-bank fire. Rept. of investigations/1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chaiken, R.F.; Bayles, L.G.

    1991-01-01

    Burnout Control is a process developed by the U.S. Bureau of Mines for accelerating the burning of wasted coal fires in situ, while at the same time controlling the heat and fumes produced. The Albright fire project is a first field trial of Burnout Control as applied to a coal waste bank. An exhaust ventilation system was designed and constructed and then operated over a 1-year period at the site of an existing abandoned mine land fire near the town of Albright, W.V. While predicted exhaust gas temperatures of 900 C and thermal power levels of 5 MW were achievedmore » at 20- to 30-in H2O vacuum levels, problems were encountered with engineering designs, equipment breakdown, and fuel-rich combustion that curtailed the time period of satisfactory operation. Effective afterburning of the exhaust gases (as they were drawn from the bank) corrected the problems associated with combustion stoichiometry and led to high thermal outputs. It is believed that with (1) improvements in engineering design and construction, (2) better control of the afterburning process, and (3) the use of conventional stack gas air-pollution controls, Burnout Control can be applied successfully to a coal waste bank fire.« less

  16. 40 CFR 60.713 - Compliance provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operator of the affected coating operation shall perform a liquid-liquid VOC material balance over each and... emission control device (other than a fixed-bed carbon adsorption system with individual exhaust stacks for...) when a fixed-bed carbon adsorption system with individual exhaust stacks for each adsorber vessel is...

  17. 40 CFR 60.713 - Compliance provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operator of the affected coating operation shall perform a liquid-liquid VOC material balance over each and... emission control device (other than a fixed-bed carbon adsorption system with individual exhaust stacks for...) when a fixed-bed carbon adsorption system with individual exhaust stacks for each adsorber vessel is...

  18. 40 CFR 60.713 - Compliance provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operator of the affected coating operation shall perform a liquid-liquid VOC material balance over each and... emission control device (other than a fixed-bed carbon adsorption system with individual exhaust stacks for...) when a fixed-bed carbon adsorption system with individual exhaust stacks for each adsorber vessel is...

  19. 28. Historic view of Building 202 exhaust scrubber stack, detail, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. Historic view of Building 202 exhaust scrubber stack, detail, July 31, 1957. On file at NASA Plumbrook Research Center, Sandusky, Ohio. NASA GRC photo number C-45648. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  20. 46 CFR 154.1200 - Mechanical ventilation system: General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Mechanical ventilation system: General. 154.1200 Section... Equipment Cargo Area: Mechanical Ventilation System § 154.1200 Mechanical ventilation system: General. (a... cargo handling equipment must have a fixed, exhaust-type mechanical ventilation system. (b) The...

  1. Technology Solutions Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Rudd and D. Bergey

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, andmore » filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs.« less

  2. 40 CFR 60.61 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... cement by either the wet or dry process. (b) Bypass means any system that prevents all or a portion of the kiln or clinker cooler exhaust gases from entering the main control device and ducts the gases... cooler emissions. (c) Bypass stack means the stack that vents exhaust gases to the atmosphere from the...

  3. 40 CFR 60.61 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... cement by either the wet or dry process. (b) Bypass means any system that prevents all or a portion of the kiln or clinker cooler exhaust gases from entering the main control device and ducts the gases... cooler emissions. (c) Bypass stack means the stack that vents exhaust gases to the atmosphere from the...

  4. 40 CFR 60.61 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... cement by either the wet or dry process. (b) Bypass means any system that prevents all or a portion of the kiln or clinker cooler exhaust gases from entering the main control device and ducts the gases... cooler emissions. (c) Bypass stack means the stack that vents exhaust gases to the atmosphere from the...

  5. 40 CFR 60.61 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... cement by either the wet or dry process. (b) Bypass means any system that prevents all or a portion of the kiln or clinker cooler exhaust gases from entering the main control device and ducts the gases... cooler emissions. (c) Bypass stack means the stack that vents exhaust gases to the atmosphere from the...

  6. 40 CFR 60.61 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... cement by either the wet or dry process. (b) Bypass means any system that prevents all or a portion of the kiln or clinker cooler exhaust gases from entering the main control device and ducts the gases... cooler emissions. (c) Bypass stack means the stack that vents exhaust gases to the atmosphere from the...

  7. 40 CFR 60.745 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... determination of the efficiency of a fixed-bed carbon adsorption system with a common exhaust stack for all the... separate runs, each coinciding with one or more complete system rotations through the adsorption cycles of... efficiency of a fixed-bed carbon adsorption system with individual exhaust stacks for each adsorber vessel...

  8. 40 CFR 60.745 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... determination of the efficiency of a fixed-bed carbon adsorption system with a common exhaust stack for all the... separate runs, each coinciding with one or more complete system rotations through the adsorption cycles of... efficiency of a fixed-bed carbon adsorption system with individual exhaust stacks for each adsorber vessel...

  9. The power of local action in occupational health: the adoption of local exhaust ventilation in the Chicago tuckpointing trade.

    PubMed

    Weinstein, Marc; Susi, Pam; Goldberg, Mark

    2016-04-01

    Silica is a pervasive and potentially deadly occupational hazard in construction. The occupational risk posed by silica has long been known, but efforts to use engineering controls to minimize dust generation in tuckpointing operations, a masonry restoration specialty, have been slow. The objective of this study is to explore how local innovation in occupational safety and health may emerge, absent the establishment of national standards. This study uses a case study to explore the adoption of local exhaust ventilation in tuckpointing operations in the Chicago area. Sources of data for this research include interviews with a diverse range of key informants and the review of archival material. This case study found local unions, municipal regulators, contractors, and major public users of construction services played a central role in the events and milestones that led to the early adoption of local exhaust ventilation in Chicago. The adoption of local exhaust ventilation technology in Chicago demonstrates the potential for local actors to fill an important void when rulemaking in vital areas of occupational of health impedes effective national regulation.

  10. 46 CFR 154.1205 - Mechanical ventilation system: Standards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Mechanical ventilation system: Standards. 154.1205... Equipment Cargo Area: Mechanical Ventilation System § 154.1205 Mechanical ventilation system: Standards. (a) Each exhaust type mechanical ventilation system required under § 154.1200 (a) must have ducts for...

  11. 46 CFR 194.20-5 - Ventilation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND... Ventilation. (a) Chemical storerooms shall be equipped with a power ventilation system of exhaust type. The... based upon the volume of the compartment. (1) Power ventilation units shall have nonsparking impellers...

  12. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudd, Armin; Bergey, Daniel

    In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the sourcemore » of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.« less

  13. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudd, Armin; Bergey, Daniel

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, themore » ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.« less

  14. FET. Exhaust duct and stack. Plan, elevation, foundation, details. Ralph ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FET. Exhaust duct and stack. Plan, elevation, foundation, details. Ralph M. Parsons 1480-10 ANP/GE-5-716-S-3. Date: February 1959. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0716-00-693-107474 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  15. Control technology for integrated circuit fabrication at Micro-Circuit Engineering, Incorporated, West Palm Beach, Florida

    NASA Astrophysics Data System (ADS)

    Mihlan, G. I.; Mitchell, R. I.; Smith, R. K.

    1984-07-01

    A survey to assess control technology for integrated circuit fabrication was conducted. Engineering controls included local and general exhaust ventilation, shielding, and personal protective equipment. Devices or work stations that contained toxic materials that were potentially dangerous were controlled by local exhaust ventilation. Less hazardous areas were controlled by general exhaust ventilation. Process isolation was used in the plasma etching, low pressure chemical vapor deposition, and metallization operations. Shielding was used in ion implantation units to control X-ray emissions, in contact mask alignes to limit ultraviolet (UV) emissions, and in plasma etching units to control radiofrequency and UV emissions. Most operations were automated. Use of personal protective equipment varied by job function.

  16. Addressing Kitchen Contaminants for Healthy, Low-Energy Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stratton, J. Chris; Singer, Brett C.

    2014-01-01

    Cooking and cooking burners emit pollutants that can adversely affect indoor air quality in residences and significantly impact occupant health. Effective kitchen exhaust ventilation can reduce exposure to cooking-related air pollutants as an enabling step to healthier, low-energy homes. This report by Lawrence Berkeley National Laboratory identifies barriers to the widespread adoption of kitchen exhaust ventilation technologies and practice and proposes a suite of strategies to overcome these barriers. The recommendations have been vetted by a group of industry, regulatory, health, and research experts and stakeholders who convened for two meetings and provided input and feedback to early drafts ofmore » this document. The most fundamental barriers are (1) the common misconception, based on a sensory perception of risk, that kitchen exhaust when cooking is unnecessary and (2) the lack of a code requirement for kitchen ventilation in most U.S. locations. Highest priority objectives include the following: (1) Raise awareness among the public and the building industry of the need to install and routinely use kitchen ventilation; (2) Incorporate kitchen exhaust ventilation as a requirement of building codes and improve the mechanisms for code enforcement; (3) Provide best practice product and use-behavior guidance to ventilation equipment purchasers and installers, and; (4) Develop test methods and performance targets to advance development of high performance products. A specific, urgent need is the development of an over-the-range microwave that meets the airflow and sound requirements of ASHRAE Standard 62.2.« less

  17. Addressing Kitchen Contaminants for Healthy, Low-Energy Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stratton, J. Chris; Singer, Brett C.

    2014-01-01

    Cooking and cooking burners emit pollutants that can adversely affect indoor air quality in residences and significantly impact occupant health. Effective kitchen exhaust ventilation can reduce exposure to cooking-related air pollutants as an enabling step to healthier, low-energy homes. This report identifies barriers to the widespread adoption of kitchen exhaust ventilation technologies and practice and proposes a suite of strategies to overcome these barriers. The recommendations have been vetted by a group of industry, regulatory, health, and research experts and stakeholders who convened for two web-based meetings and provided input and feedback to early drafts of this document. The mostmore » fundamental barriers are (1) the common misconception, based on a sensory perception of risk, that kitchen exhaust when cooking is unnecessary and (2) the lack of a code requirement for kitchen ventilation in most US locations. Highest priority objectives include the following: (1) Raise awareness among the public and the building industry of the need to install and routinely use kitchen ventilation; (2) Incorporate kitchen exhaust ventilation as a requirement of building codes and improve the mechanisms for code enforcement; (3) Provide best practice product and use-behavior guidance to ventilation equipment purchasers and installers, and; (4) Develop test methods and performance targets to advance development of high performance products. A specific, urgent need is the development of an over-the-range microwave that meets the airflow and sound requirements of ASHRAE Standard 62.2.« less

  18. Building America Case Study: Evaluation of Ventilation Strategies in New Construction Multifamily Buildings, New York, New York (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-09-01

    In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the 'fresh' air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the 'normal leakage paths through the building envelope' disappear. CARB researchers have found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air tomore » apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. Product performance data are based on laboratory tests, and the assumption is that products will perform similarly in the field. Proper application involves matching expected performance at expected building pressures, but there is no guarantee that those conditions will exist consistently in the finished building. This research effort, which included several weeks of building pressure monitoring, sought to provide field validation of system performance. The performance of four substantially different strategies for providing make-up air to apartments was evaluated.« less

  19. Characteristics of rain penetration through a gravity ventilator used for natural ventilation.

    PubMed

    Kim, Taehyeung; Lee, Dong Ho; Ahn, Kwangseog; Ha, Hyunchul; Park, Heechang; Piao, Cheng Xu; Li, Xiaoyu; Seo, Jeoungyoon

    2008-01-01

    Gravity ventilators rely simply on air buoyancy to extract air and are widely used to exhaust air contaminants and heat from workplaces using minimal energy. They are designed to maximize the exhaust flow rate, but the rain penetration sometimes causes malfunctioning. In this study, the characteristics of rain penetration through a ventilator were examined as a preliminary study to develop a ventilator with the maximum exhaust capacity while minimizing rain penetration. A model ventilator was built and exposed to artificial rain and wind. The paths, intensities and amounts of penetration through the ventilator were observed and measured in qualitative and quantitative fashions. In the first phase, the pathways and intensities of rain penetration were visually observed. In the second phase, the amounts of rain penetration were quantitatively measured under the different configurations of ventilator components that were installed based on the information obtained in the first-phase experiment. The effects of wind speed, grill direction, rain drainage width, outer wall height, neck height and leaning angle of the outer wall from the vertical position were analyzed. Wind speed significantly affected rain penetration. Under the low crosswind conditions, the rain penetration intensities were under the limit of detection. Under the high crosswind conditions, grill direction and neck height were the most significant factors in reducing rain penetration. The installation of rain drainage was also important in reducing rain penetration. The experimental results suggest that, with proper configurations of its components, a gravity ventilator can be used for natural ventilation without significant rain penetration problems.

  20. IET exhaust gas stack. Section, west elevation, foundation plan, access ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    IET exhaust gas stack. Section, west elevation, foundation plan, access ladder, airplane warning light. Ralph M. Parsons 902-5-ANP-712-S 433. Date: May 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0712-60-693-106984 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  1. Field study of exhaust fans for mitigating indoor air quality problems: Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grimsrud, D.T.; Szydlowski, R.F.; Turk, B.H.

    1986-09-01

    Residential ventilation in the United States housing stock is provided primarily by infiltration, the natural leakage of outdoor air into a building through cracks and holes in the building shell. Since ventilation is the dominant mechanism for control of indoor pollutant concentrations, low infiltration rates caused fluctuation in weather conditions may lead to high indoor pollutant concentrations. Supplemental mechanical ventilation can be used to eliminate these periods of low infiltration. This study examined effects of small continuously-operating exhaust fan on pollutant concentrations and energy use in residences.

  2. The power of local action in occupational health: the adoption of local exhaust ventilation in the Chicago tuckpointing trade

    PubMed Central

    2016-01-01

    Background Silica is a pervasive and potentially deadly occupational hazard in construction. The occupational risk posed by silica has long been known, but efforts to use engineering controls to minimize dust generation in tuckpointing operations, a masonry restoration specialty, have been slow. Objectives The objective of this study is to explore how local innovation in occupational safety and health may emerge, absent the establishment of national standards. Method This study uses a case study to explore the adoption of local exhaust ventilation in tuckpointing operations in the Chicago area. Sources of data for this research include interviews with a diverse range of key informants and the review of archival material. Results This case study found local unions, municipal regulators, contractors, and major public users of construction services played a central role in the events and milestones that led to the early adoption of local exhaust ventilation in Chicago. The adoption of local exhaust ventilation technology in Chicago demonstrates the potential for local actors to fill an important void when rulemaking in vital areas of occupational of health impedes effective national regulation. PMID:27362634

  3. 46 CFR 185.352 - Ventilation of gasoline machinery spaces.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Ventilation of gasoline machinery spaces. 185.352... (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.352 Ventilation of gasoline machinery spaces. The mechanical exhaust for the ventilation of a gasoline machinery space, required by...

  4. 46 CFR 185.352 - Ventilation of gasoline machinery spaces.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Ventilation of gasoline machinery spaces. 185.352... (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.352 Ventilation of gasoline machinery spaces. The mechanical exhaust for the ventilation of a gasoline machinery space, required by...

  5. 46 CFR 185.352 - Ventilation of gasoline machinery spaces.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Ventilation of gasoline machinery spaces. 185.352... (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.352 Ventilation of gasoline machinery spaces. The mechanical exhaust for the ventilation of a gasoline machinery space, required by...

  6. Assessment of the LV-S2 & LV-S3 Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.

    2014-09-30

    This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 1-2A exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LV-C2, LV-S2, and LV-S3 exhaust stacks were tested together as a group (Test Group 1-2A). This report only covers the results of LV-S2 and LV-S3; LV-C2 will be reported on separately. Federal regulations1 require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Healthmore » Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. 2 These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.« less

  7. Generic particulate-monitoring system for retrofit to Hanford exhaust stacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Camman, J.W.; Carbaugh, E.H.

    1982-11-01

    Evaluations of 72 sampling and monitoring systems were performed at Hanford as the initial phase of a program to upgrade such systems. Each evaluation included determination of theoretical sampling efficiencies for particle sizes ranging from 0.5 to 10 micrometers aerodynamic equivalent diameter, addressing anisokinetic bias, sample transport line losses, and collector device efficiency. Upgrades needed to meet current Department of Energy guidance for effluent sampling and monitoring were identified, and a cost for each upgrade was estimated. A relative priority for each system's upgrade was then established based on evaluation results, current operational status, and future plans for the facilitymore » being exhausted. Common system upgrade requirements lead to the development of a generic design for common components of an exhaust stack sampling and monitoring system for airborne radioactive particulates. The generic design consists of commercially available off-the-shelf components to the extent practical and will simplify future stack sampling and monitoring system design, fabrication, and installation efforts. Evaluation results and their significance to system upgrades are empasized. A brief discussion of the analytical models used and experience to date with the upgrade program is included. Development of the generic stack sampling and monitoring system design is outlined. Generic system design features and limitations are presented. Requirements for generic system retrofitting to existing exhaust stacks are defined and benefits derived from generic system application are discussed.« less

  8. Critical flow rate of anode fuel exhaust in a PEM fuel cell system

    NASA Astrophysics Data System (ADS)

    Zhu, Wenhua H.; Payne, Robert U.; Tatarchuk, Bruce J.

    A manual purge line was added into the exterior fuel exhaust stream of a Ballard PEM stack in a Nexa™ power module. With the addition of manual exhaust purge, high levels of inert gases were intentionally added to the anode feed without changing normal operational procedures. A new method of determining the critical minimum flow rate in the anode exhaust stream was given by an anode mass balance. This type of operation makes dual use of membranes in the MEAs as both gas purifiers and as solid electrolytes. The PEM stack was successfully operated with up to ca. 7% nitrogen or carbon dioxide in the absence of a palladium-based hydrogen separator at ca. 200 W power level. Nitrogen in the anode stream was concentrated from 7.5% to 91.6%. The system maintained a fuel efficiency of 99% at a manual purge rate of 2.22 ml s -1 and no auto purge. The fuel cell stack efficiency was 64% and the stack output efficiency was 75%. The overall system efficiency was 39%. After troublesome CO and H 2S poisons were removed, a hydrocarbon reformate containing high levels of CO 2 and H 2O was further used in the Nexa™ stack. The size and complexity of the fuel processing system may be reduced at a specified power level by using this operational method.

  9. Influence of Rack Design and Disease Prevalence on Detection of Rodent Pathogens in Exhaust Debris Samples from Individually Ventilated Caging Systems.

    PubMed

    Bauer, Beth A; Besch-Williford, Cynthia; Livingston, Robert S; Crim, Marcus J; Riley, Lela K; Myles, Matthew H

    2016-11-01

    Sampling of bedding debris within the exhaust systems of ventilated racks may be a mechanism for detecting murine pathogens in colony animals. This study examined the effectiveness of detecting pathogens by PCR analysis of exhaust debris samples collected from ventilated racks of 2 different rack designs, one with unfiltered air flow from within the cage to the air-exhaust pathway, and the other had a filter between the cage and the air-exhaust pathway. For 12 wk, racks were populated with either 1 or 5 cages of mice (3 mice per cage) infected with one of the following pathogens: mouse norovirus (MNV), mouse parvovirus (MPV), mouse hepatitis virus (MHV), Helicobacter spp., Pasteurella pneumotropica, pinworms, Entamoeba muris, Tritrichomonas muris, and fur mites. Pathogen shedding by infected mice was monitored throughout the study. In the filter-containing rack, PCR testing of exhaust plenums yielded negative results for all pathogens at all time points of the study. In the rack with open air flow, pathogens detected by PCR analysis of exhaust debris included MHV, Helicobacter spp., P. pneumotropica, pinworms, enteric protozoa, and fur mites; these pathogens were detected in racks housing either 1 or 5 cages of infected mice. Neither MPV nor MNV was detected in exhaust debris, even though prolonged viral shedding was confirmed. These results demonstrate that testing rack exhaust debris from racks with unfiltered air flow detected MHV, enteric bacteria and parasites, and fur mites. However, this method failed to reliably detect MNV or MPV infection of colony animals.

  10. Influence of Rack Design and Disease Prevalence on Detection of Rodent Pathogens in Exhaust Debris Samples from Individually Ventilated Caging Systems

    PubMed Central

    Bauer, Beth A; Besch-Williford, Cynthia; Livingston, Robert S; Crim, Marcus J; Riley, Lela K; Myles, Matthew H

    2016-01-01

    Sampling of bedding debris within the exhaust systems of ventilated racks may be a mechanism for detecting murine pathogens in colony animals. This study examined the effectiveness of detecting pathogens by PCR analysis of exhaust debris samples collected from ventilated racks of 2 different rack designs, one with unfiltered air flow from within the cage to the air-exhaust pathway, and the other had a filter between the cage and the air-exhaust pathway. For 12 wk, racks were populated with either 1 or 5 cages of mice (3 mice per cage) infected with one of the following pathogens: mouse norovirus (MNV), mouse parvovirus (MPV), mouse hepatitis virus (MHV), Helicobacter spp., Pasteurella pneumotropica, pinworms, Entamoeba muris, Tritrichomonas muris, and fur mites. Pathogen shedding by infected mice was monitored throughout the study. In the filter-containing rack, PCR testing of exhaust plenums yielded negative results for all pathogens at all time points of the study. In the rack with open air flow, pathogens detected by PCR analysis of exhaust debris included MHV, Helicobacter spp., P. pneumotropica, pinworms, enteric protozoa, and fur mites; these pathogens were detected in racks housing either 1 or 5 cages of infected mice. Neither MPV nor MNV was detected in exhaust debris, even though prolonged viral shedding was confirmed. These results demonstrate that testing rack exhaust debris from racks with unfiltered air flow detected MHV, enteric bacteria and parasites, and fur mites. However, this method failed to reliably detect MNV or MPV infection of colony animals. PMID:27931317

  11. Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV-S3, HV-S3A and HV-S3B Exhaust Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flaherty, Julia E.; Glissmeyer, John A.

    2015-03-18

    Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilutionmore » system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 μm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.« less

  12. Fresh air indoors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kull, K.

    1988-09-01

    This article describes and compares ventilation systems for the control of indoor air pollution in residential housing. These include: local exhaust fans, whole-house fans, central exhaust with wall ports, and heat-recovery central ventilation (HRV). HRV's have a higher initial cost than the other systems but they are the only ones that save energy. Homeowners are given guidelines for choosing the system best suited for their homes in terms of efficiency and payback period.

  13. Design local exhaust ventilation on sieve machine at PT.Perkebunan Nusantara VIII Ciater using design for assembly (DFA) approach with Boothroyd and Dewhurst method

    NASA Astrophysics Data System (ADS)

    Khalqihi, K. I.; Rahayu, M.; Rendra, M.

    2017-12-01

    PT Perkebunan Nusantara VIII Ciater is a company produced black tea orthodox more or less 4 tons every day. At the production section, PT Perkebunan Nusantara VIII will use local exhaust ventilation specially at sortation area on sieve machine. To maintain the quality of the black tea orthodox, all machine must be scheduled for maintenance every once a month and takes time 2 hours in workhours, with additional local exhaust ventilation, it will increase time for maintenance process, if maintenance takes time more than 2 hours it will caused production process delayed. To support maintenance process in PT Perkebunan Nusantara VIII Ciater, designing local exhaust ventilation using design for assembly approach with Boothroyd and Dewhurst method, design for assembly approach is choosen to simplify maintenance process which required assembly process. There are 2 LEV designs for this research. Design 1 with 94 components, assembly time 647.88 seconds and assembly efficiency level 23.62%. Design 2 with 82 components, assembly time 567.84 seconds and assembly efficiency level 24.83%. Design 2 is choosen for this research based on DFA goals, minimum total part that use, optimization assembly time, and assembly efficiency level.

  14. Wind Tunnel Model Study of the Hot Exhaust Plume from the Compressor Research Facility at Wright-Patterson Air Force Base, Ohio

    DTIC Science & Technology

    1977-10-01

    PLUME FROM THE COMPRESSOR JtESEARCHJAC ILITY AT WRIGHT- /ATTERSON AIR FORCE JBASE, OHIO , r= mrm (.) Gary R./Ludwig 9. PERFORMING ORGANIZATION NAME... ms Mass flux of stack exhaust gas (slugs/sec) nrtfl Mass flux of ambient air and stack exhaust gas mixture st plume cross-section A (slugs/sec...the horizontal momentum flux in the ambient wind be the same in the model as it is in full-scale. /»» Ms M i a. ’ ro P>"S P*» + ’f (3) where 0

  15. 29 CFR 1910.1025 - Lead.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reflect the current status of the program. (4) Mechanical ventilation. (i) When ventilation is used to...) Recirculation of air. If air from exhaust ventilation is recirculated into the workplace, the employer shall... protective clothing or equipment of the potentially harmful effects of exposure to lead. (vii) The employer...

  16. 29 CFR 1910.1025 - Lead.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reflect the current status of the program. (4) Mechanical ventilation. (i) When ventilation is used to...) Recirculation of air. If air from exhaust ventilation is recirculated into the workplace, the employer shall... protective clothing or equipment of the potentially harmful effects of exposure to lead. (vii) Labeling of...

  17. 29 CFR 1910.1025 - Lead.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reflect the current status of the program. (4) Mechanical ventilation. (i) When ventilation is used to...) Recirculation of air. If air from exhaust ventilation is recirculated into the workplace, the employer shall... protective clothing or equipment of the potentially harmful effects of exposure to lead. (vii) Labeling of...

  18. 29 CFR 1910.1025 - Lead.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reflect the current status of the program. (4) Mechanical ventilation. (i) When ventilation is used to...) Recirculation of air. If air from exhaust ventilation is recirculated into the workplace, the employer shall... protective clothing or equipment of the potentially harmful effects of exposure to lead. (vii) The employer...

  19. 29 CFR 1910.1025 - Lead.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reflect the current status of the program. (4) Mechanical ventilation. (i) When ventilation is used to...) Recirculation of air. If air from exhaust ventilation is recirculated into the workplace, the employer shall... protective clothing or equipment of the potentially harmful effects of exposure to lead. (vii) Labeling of...

  20. 9 CFR 3.51 - Facilities, indoor.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... ventilated so as to minimize drafts, odors, and moisture condensation. Auxiliary ventilation, such as exhaust... maintained so that they are substantially impervious to moisture and may be readily sanitized. ...

  1. 9 CFR 3.51 - Facilities, indoor.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... ventilated so as to minimize drafts, odors, and moisture condensation. Auxiliary ventilation, such as exhaust... maintained so that they are substantially impervious to moisture and may be readily sanitized. ...

  2. 9 CFR 3.51 - Facilities, indoor.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... ventilated so as to minimize drafts, odors, and moisture condensation. Auxiliary ventilation, such as exhaust... maintained so that they are substantially impervious to moisture and may be readily sanitized. ...

  3. In-depth survey report: Evaluation of a ventilation system to control formaldehyde exposures during embalming at Cincinnati College of Mortuary Science, Cincinnati, Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gressel, M.G.

    1990-12-01

    The goal of the study was to develop and evaluate local exhaust ventilation controls which will reduce the embalmer's exposure to formaldehyde (50000). The Cincinnati College of Mortuary Science had three tables set up for conducting embalmings. Two of the tables were in a large room which serves as a laboratory for the students. The third was located in an isolation room and was used primarily for suspected infectious cases. All the embalmings conducted for the study were conducted in the isolation room and all involved noninfectious bodies. The local exhaust ventilation system developed for the mortuary consisted of 6more » foot slot hoods on either side of the embalming table. Of the 32 personal samples taken, the formaldehyde concentration of five samples showed a concentration of 1 part per million. The author recommends that a local exhaust ventilation system similar to the design tested here be installed permanently in the isolation room and on the other tables in the main embalming laboratory.« less

  4. Exhaust ventilation in attached garages improves residential indoor air quality.

    PubMed

    Mallach, G; St-Jean, M; MacNeill, M; Aubin, D; Wallace, L; Shin, T; Van Ryswyk, K; Kulka, R; You, H; Fugler, D; Lavigne, E; Wheeler, A J

    2017-03-01

    Previous research has shown that indoor benzene levels in homes with attached garages are higher than homes without attached garages. Exhaust ventilation in attached garages is one possible intervention to reduce these concentrations. To evaluate the effectiveness of this intervention, a randomized crossover study was conducted in 33 Ottawa homes in winter 2014. VOCs including benzene, toluene, ethylbenzene, and xylenes, nitrogen dioxide, carbon monoxide, and air exchange rates were measured over four 48-hour periods when a garage exhaust fan was turned on or off. A blower door test conducted in each garage was used to determine the required exhaust fan flow rate to provide a depressurization of 5 Pa in each garage relative to the home. When corrected for ambient concentrations, the fan decreased geometric mean indoor benzene concentrations from 1.04 to 0.40 μg/m 3 , or by 62% (P<.05). The garage exhaust fan also significantly reduced outdoor-corrected geometric mean indoor concentrations of other pollutants, including toluene (53%), ethylbenzene (47%), m,p-xylene (45%), o-xylene (43%), and carbon monoxide (23%) (P<.05) while having no impact on the home air exchange rate. This study provides evidence that mechanical exhaust ventilation in attached garages can reduce indoor concentrations of pollutants originating from within attached garages. © 2016 Her Majesty the Queen in Right of Canada. Indoor Air published by John Wiley & Sons Ltd.

  5. 46 CFR 185.352 - Ventilation of gasoline machinery spaces.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Ventilation of gasoline machinery spaces. 185.352... machinery spaces. The mechanical exhaust for the ventilation of a gasoline machinery space, required by... sufficient to insure at least one complete change of air in the space served. ...

  6. 46 CFR 185.352 - Ventilation of gasoline machinery spaces.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Ventilation of gasoline machinery spaces. 185.352... machinery spaces. The mechanical exhaust for the ventilation of a gasoline machinery space, required by... sufficient to insure at least one complete change of air in the space served. ...

  7. 40 CFR 60.743 - Compliance provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... operations not using carbon adsorption beds with individual exhausts. This method is applicable when the... carbon adsorption system with individual exhaust stacks for each adsorber vessel. The owner or operator... operations using carbon adsorption beds with individual exhausts. This method is applicable when emissions...

  8. 40 CFR 60.743 - Compliance provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... operations not using carbon adsorption beds with individual exhausts. This method is applicable when the... carbon adsorption system with individual exhaust stacks for each adsorber vessel. The owner or operator... operations using carbon adsorption beds with individual exhausts. This method is applicable when emissions...

  9. 40 CFR 60.743 - Compliance provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operations not using carbon adsorption beds with individual exhausts. This method is applicable when the... carbon adsorption system with individual exhaust stacks for each adsorber vessel. The owner or operator... operations using carbon adsorption beds with individual exhausts. This method is applicable when emissions...

  10. 30 CFR 75.326 - Mean entry air velocity.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... exhausting face ventilation systems, the mean entry air velocity shall be at least 60 feet per minute reaching each working face where coal is being cut, mined, drilled for blasting, or loaded, and to any... the inby end of the line curtain, ventilation tubing, or other face ventilation control devices. [61...

  11. 30 CFR 75.326 - Mean entry air velocity.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... exhausting face ventilation systems, the mean entry air velocity shall be at least 60 feet per minute reaching each working face where coal is being cut, mined, drilled for blasting, or loaded, and to any... the inby end of the line curtain, ventilation tubing, or other face ventilation control devices. [61...

  12. 30 CFR 75.326 - Mean entry air velocity.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... exhausting face ventilation systems, the mean entry air velocity shall be at least 60 feet per minute reaching each working face where coal is being cut, mined, drilled for blasting, or loaded, and to any... the inby end of the line curtain, ventilation tubing, or other face ventilation control devices. [61...

  13. Effect on combined cycle efficiency of stack gas temperature constraints to avoid acid corrosion

    NASA Technical Reports Server (NTRS)

    Nainiger, J. J.

    1980-01-01

    To avoid condensation of sulfuric acid in the gas turbine exhaust when burning fuel oils contaning sulfur, the exhaust stack temperature and cold-end heat exchanger surfaces must be kept above the condensation temperature. Raising the exhaust stack temperature, however, results in lower combined cycle efficiency compared to that achievable by a combined cycle burning a sulfur-free fuel. The maximum difference in efficiency between the use of sulfur-free and fuels containing 0.8 percent sulfur is found to be less than one percentage point. The effect of using a ceramic thermal barrier coating (TBC) and a fuel containing sulfur is also evaluated. The combined-cycle efficiency gain using a TBC with a fuel containing sulfur compared to a sulfur-free fuel without TBC is 0.6 to 1.0 percentage points with air-cooled gas turbines and 1.6 to 1.8 percentage points with water-cooled gas turbines.

  14. 46 CFR 169.625 - Compartments containing diesel machinery.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... structure. Prior to installing ventilation for the engines, plans or sketches showing the machinery... mechanical supply and exhaust ventilation. One duct must extend to a point near the bottom of the compartment...

  15. 46 CFR 169.625 - Compartments containing diesel machinery.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... structure. Prior to installing ventilation for the engines, plans or sketches showing the machinery... mechanical supply and exhaust ventilation. One duct must extend to a point near the bottom of the compartment...

  16. 46 CFR 169.625 - Compartments containing diesel machinery.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... structure. Prior to installing ventilation for the engines, plans or sketches showing the machinery... mechanical supply and exhaust ventilation. One duct must extend to a point near the bottom of the compartment...

  17. 40 CFR 63.421 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... entire vapor processing system except the exhaust port(s) or stack(s). Flare means a thermal oxidation...(ee). Thermal oxidation system means a combustion device used to mix and ignite fuel, air pollutants...

  18. 40 CFR 63.421 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... entire vapor processing system except the exhaust port(s) or stack(s). Flare means a thermal oxidation...(ee). Thermal oxidation system means a combustion device used to mix and ignite fuel, air pollutants...

  19. 40 CFR 63.421 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... entire vapor processing system except the exhaust port(s) or stack(s). Flare means a thermal oxidation...(ee). Thermal oxidation system means a combustion device used to mix and ignite fuel, air pollutants...

  20. 40 CFR 63.421 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... entire vapor processing system except the exhaust port(s) or stack(s). Flare means a thermal oxidation...(ee). Thermal oxidation system means a combustion device used to mix and ignite fuel, air pollutants...

  1. 46 CFR 38.20-10 - Ventilation-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... equipped with power ventilation of the exhaust type having capacity sufficient to effect a complete change of air in not more than 3 minutes equal to the volume of the compartment and associated trunks. (b) The power ventilation units shall not produce a source of vapor ignition in either the compartment or...

  2. Modular fuel-cell stack assembly

    DOEpatents

    Patel, Pinakin [Danbury, CT; Urko, Willam [West Granby, CT

    2008-01-29

    A modular multi-stack fuel-cell assembly in which the fuel-cell stacks are situated within a containment structure and in which a gas distributor is provided in the structure and distributes received fuel and oxidant gases to the stacks and receives exhausted fuel and oxidant gas from the stacks so as to realize a desired gas flow distribution and gas pressure differential through the stacks. The gas distributor is centrally and symmetrically arranged relative to the stacks so that it itself promotes realization of the desired gas flow distribution and pressure differential.

  3. The Multiple Inert Gas Elimination Technique: A User’s Manual

    DTIC Science & Technology

    2016-02-11

    These quantities are measured for inspired and expired oxygen and carbon dioxide, as well as minute ventilation . Expired Gas Sampling...Schematic of Ventilator /MIGET Sampling Circuit” (pp 28-30). By this mode, the ventilator is effectively , completely excluded from the sampling apparatus...connects the subject to the mixing box and the exhaust from the mixing box to the ventilator , temperature control is of the highest priority. The tubing

  4. Control of Nitrogen Dioxide in Stack Emission by Reaction with Ammonia

    NASA Technical Reports Server (NTRS)

    Metzler, A. J.; Stevenson, E. F.

    1970-01-01

    The development of an acid base gas-phase reaction system which utilizes anhydrous ammonia as the reactant to remove nitrogen dioxide from hydrazine-nitrogen tetroxide rocket combustion exhaust is reported. This reaction reduced NO2 levels in exhaust emissions so that the resulting stack emission is completely white instead of the earlier observed typical reddish-brown coloration. Preliminary analyses indicate the importance of reaction time and ammonia concentration on removal efficiency and elimination of the health hazard to individuals with respiratory problems.

  5. Enclosed ground-flare incinerator

    DOEpatents

    Wiseman, Thomas R.

    2000-01-01

    An improved ground flare is provided comprising a stack, two or more burner assemblies, and a servicing port so that some of the burner assemblies can be serviced while others remain in operation. The burner assemblies comprise a burner conduit and nozzles which are individually fitted to the stack's burner chamber and are each removably supported in the chamber. Each burner conduit is sealed to and sandwiched between a waste gas inlet port and a matching a closure port on the other side of the stack. The closure port can be opened for physically releasing the burner conduit and supplying sufficient axial movement room for extracting the conduit from the socket, thereby releasing the conduit for hand removal through a servicing port. Preferably, the lower end of the stack is formed of one or more axially displaced lower tubular shells which are concentrically spaced for forming annular inlets for admitting combustion air. An upper tubular exhaust stack, similarly formed, admits additional combustion air for increasing the efficiency of combustion, increasing the flow of exhausted for improved atmospheric dispersion and for cooling the upper stack.

  6. The near-source impacts of diesel backup generators in urban environments

    NASA Astrophysics Data System (ADS)

    Tong, Zheming; Zhang, K. Max

    2015-05-01

    Distributed power generation, located close to consumers, plays an important role in the current and future power systems. However, its near-source impacts in complex urban environments are not well understood. In this paper, we focused on diesel backup generators that participate in demand response (DR) programs. We first improved the micro-environmental air quality simulations by employing a meteorology processor, AERMET, to generate site-specific boundary layer parameters for the Large Eddy Simulation (LES) modeling. The modeling structure was then incorporated into the CTAG model to evaluate the environmental impacts of diesel backup generators in near-source microenvironments. We found that the presence of either tall upwind or downwind building can deteriorate the air quality in the near-stack street canyons, largely due to the recirculation zones generated by the tall buildings, reducing the near-stack dispersion. Decreasing exhaust momentum ratio (stack exit velocity/ambient wind velocity) draws more exhaust into the recirculation zone, and reduces the effective stack height, which results in elevated near-ground concentrations inside downwind street canyons. The near-ground PM2.5 concentration for the worst scenarios could well exceed 100 μg m-3, posing potential health risk to people living and working nearby. In general, older diesel backup generators (i.e., Tier 1, 2 or older) without the up-to-date emission control may significantly increase the pollutant concentration in the near-source street canyons if participating in DR programs. Even generators that comply with Tier-4 standards could lead to PM hotspots if their stacks are next to tall buildings. Our study implies that the siting of diesel backup generators stacks should consider not only the interactions of fresh air intake and exhaust outlet for the building housing the backup generators, but also the dispersion of exhaust plumes in the surrounding environment.

  7. 29 CFR 1910.124 - General requirements for dipping and coating operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Chemical reaction. (c) What requirements must I follow to recirculate exhaust air into the workplace? (1) You may not recirculate exhaust air when any substance in that air poses a health hazard to employees... Liquids. (5) When you use mechanical ventilation, it must draw the flow of air into a hood or exhaust duct...

  8. 46 CFR 28.340 - Ventilation of enclosed engine and fuel tank spaces.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... prevent the entrapment of vapors or be ventilated by a mechanical exhaust system with a nonsparking fan. The fan motor must comply with 46 CFR 111.105-23. (c) Alternative standards. A vessel less than 65...

  9. Building America Case Study: Sealed Crawl Spaces with Integrated Whole-House Ventilation in a Cold Climate, Ithaca, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    "9One method of code-compliance for crawlspaces is to seal and insulate the crawlspace, rather than venting to the outdoors. However, codes require mechanical ventilation; either via conditioned supply air from the HVAC system, or a continuous exhaust ventilation strategy. As the CARB's building partner, Ithaca Neighborhood Housing Services, intended to use the unvented crawlspace in a recent development, CARB was interested in investigating a hybrid ventilation method that includes the exhaust air from the crawlspace as a portion of an ASHRAE 62.2 compliant whole-house ventilation strategy. This hybrid ventilation method was evaluated through a series of long-term monitoring tests thatmore » observed temperature, humidity, and pressure conditions through the home and crawlspace. Additionally, CARB worked with NREL to perform multi-point tracer gas testing on six separate ventilation strategies - varying portions of 62.2 required flow supplied by the crawlspace fan and an upstairs bathroom fan. The intent of the tracer gas testing was to identify effective Reciprocal Age of Air (RAoA), which is equivalent to the air change rate in well-mixed zones, for each strategy while characterizing localized infiltration rates in several areas of the home.« less

  10. SY Tank Farm ventilation isolation option risk assessment report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powers, T.B.; Morales, S.D.

    The safety of the 241-SY Tank Farm ventilation system has been under extensive scrutiny due to safety concerns associated with tank 101-SY. Hydrogen and other gases are generated and trapped in the waste below the liquid surface. Periodically, these gases are released into the dome space and vented through the exhaust system. This attention to the ventilation system has resulted in the development of several alternative ventilation system designs. The ventilation system provides the primary means of mitigation of accidents associated with flammable gases. This report provides an assessment of various alternatives ventilation system designs.

  11. Determinants of Wood Dust Exposure in the Danish Furniture Industry—Results from Two Cross-Sectional Studies 6 Years Apart

    PubMed Central

    Schlünssen, Vivi; Jacobsen, Gitte; Erlandsen, Mogens; Mikkelsen, Anders B.; Schaumburg, Inger; Sigsgaard, Torben

    2008-01-01

    Objectives: This paper investigates determinants of wood dust exposure and trends in dust level in the furniture industry of Viborg County, Denmark, using data from two cross-sectional studies 6 years apart. Methods: During the winter 1997/1998, 54 factories were visited (hereafter study 1). In the winter 2003/2004, 27 factories were revisited, and personal dust measurements were repeated. In addition, 14 new factories were included (hereafter study 2). A total of 2303 woodworkers participated in study 1, and 2358 measurements from 1702 workers were available. From study 2, 1581 woodworkers participated and 1355 measurements from 1044 workers were available. Information on occupational variables describing potential determinants of exposures like work task, exhaust ventilation, enclosure and cleaning procedures were collected. A total of 2627 measurements and 1907 persons were included in the final mixed model in order to explore determinants of exposure and trends in dust level. Results: The overall inhalable wood dust concentration (geometric means (geometric standard deviation)) has decreased from 0.95 mg/m3 (2.05) in study 1 to 0.60 mg/m3 (1.63) in study 2, representing a 7% annual decrease in dust concentration, which was confirmed in the mixed model. From study 1 to study 2 there has been a change towards less manual work and more efficient cleaning methods, but on the contrary also more inadequate exhaust ventilation systems. The following determinants were found to ‘increase’ dust concentration: sanding; use of compressed air; use of full-automatic machines; manual work; cleaning of work pieces with compressed air; kitchen producing factories and small factories (<20 employees). The following determinants of exposure were found to ‘decrease’ dust concentration: manual assembling/packing; sanding with adequate exhaust ventilation; adequate exhaust ventilation; vacuum cleaning of machines and special cleaning staff. Conclusions: Despite a substantial drop in the dust concentration during the last 6 years in the furniture industry in Viborg County, further improvements are possible. There should be more focus on improved exhaust ventilation, professional cleaning methods and avoiding use of compressed air. PMID:18407937

  12. Determinants of wood dust exposure in the Danish furniture industry--results from two cross-sectional studies 6 years apart.

    PubMed

    Schlünssen, Vivi; Jacobsen, Gitte; Erlandsen, Mogens; Mikkelsen, Anders B; Schaumburg, Inger; Sigsgaard, Torben

    2008-06-01

    This paper investigates determinants of wood dust exposure and trends in dust level in the furniture industry of Viborg County, Denmark, using data from two cross-sectional studies 6 years apart. During the winter 1997/1998, 54 factories were visited (hereafter study 1). In the winter 2003/2004, 27 factories were revisited, and personal dust measurements were repeated. In addition, 14 new factories were included (hereafter study 2). A total of 2303 woodworkers participated in study 1, and 2358 measurements from 1702 workers were available. From study 2, 1581 woodworkers participated and 1355 measurements from 1044 workers were available. Information on occupational variables describing potential determinants of exposures like work task, exhaust ventilation, enclosure and cleaning procedures were collected. A total of 2627 measurements and 1907 persons were included in the final mixed model in order to explore determinants of exposure and trends in dust level. The overall inhalable wood dust concentration (geometric means (geometric standard deviation)) has decreased from 0.95 mg/m(3) (2.05) in study 1 to 0.60 mg/m(3) (1.63) in study 2, representing a 7% annual decrease in dust concentration, which was confirmed in the mixed model. From study 1 to study 2 there has been a change towards less manual work and more efficient cleaning methods, but on the contrary also more inadequate exhaust ventilation systems. The following determinants were found to 'increase' dust concentration: sanding; use of compressed air; use of full-automatic machines; manual work; cleaning of work pieces with compressed air; kitchen producing factories and small factories (<20 employees). The following determinants of exposure were found to 'decrease' dust concentration: manual assembling/packing; sanding with adequate exhaust ventilation; adequate exhaust ventilation; vacuum cleaning of machines and special cleaning staff. Despite a substantial drop in the dust concentration during the last 6 years in the furniture industry in Viborg County, further improvements are possible. There should be more focus on improved exhaust ventilation, professional cleaning methods and avoiding use of compressed air.

  13. Evaluation of a local exhaust system used in the manufacture of small parts made of reinforced plastic.

    PubMed

    Lazure, L P

    2000-09-01

    Fiber-reinforced plastics are used to manufacture a large variety of products, particularly for the transportation sector. Hand lay-up molding and projection molding are the main methods of manufacture. The users of these processes are exposed to appreciable emissions of styrene; in Quebec, more than 3000 workers work in this industry. A statistical analysis of styrene concentrations measured over a five-year period by the Institut de recherche en santé et en sécurité du travail (IRSST, Occupational Health and Safety Research Institute) reveals that for all of the main manufacturing sectors involved, between 40 percent and 78 percent of the results exceed the exposure standard of 50 ppm. This study evaluated the effectiveness of a ventilated table in controlling worker exposure to styrene and acetone in a shop that manufactures fiber-reinforced plastics parts. The evaluated local extraction system consists of a ventilated table with a surface area of 1.2 m x 1.2 m. During molding, the styrene emissions are exhausted through the ventilated table as well as through the slots in a lateral hood. Replacement air, introduced vertically through a supply air shower located above the worker, limits the diffusion of contaminants toward the worker's breathing zone. The reduction in worker exposure to styrene and acetone during hand lay-up molding was measured in the breathing zone for two sizes of molds. The results show that exhaust ventilation reduced the styrene concentrations by 91 percent and that the introduction of replacement air increased the efficiency of the ventilated table to 96 percent. The evaluation performed indicates that the ventilated table adequately controls worker exposure to styrene and acetone during the molding of small components.

  14. Ventilation Rates and Airflow Pathways in Patient Rooms: A Case Study of Bioaerosol Containment and Removal.

    PubMed

    Mousavi, Ehsan S; Grosskopf, Kevin R

    2015-11-01

    Most studies on the transmission of infectious airborne disease have focused on patient room air changes per hour (ACH) and how ACH provides pathogen dilution and removal. The logical but mostly unproven premise is that greater air change rates reduce the concentration of infectious particles and thus, the probability of airborne disease transmission. Recently, a growing body of research suggests pathways between pathogenic source (patient) and control (exhaust) may be the dominant environmental factor. While increases in airborne disease transmission have been associated with ventilation rates below 2 ACH, comparatively less data are available to quantify the benefits of higher air change rates in clinical spaces. As a result, a series of tests were conducted in an actual hospital to observe the containment and removal of respirable aerosols (0.5-10 µm) with respect to ventilation rate and directional airflow in a general patient room, and, an airborne infectious isolation room. Higher ventilation rates were not found to be proportionately effective in reducing aerosol concentrations. Specifically, increasing mechanical ventilation from 2.5 to 5.5 ACH reduced aerosol concentrations only 30% on average. However, particle concentrations were more than 40% higher in pathways between the source and exhaust as was the suspension and migration of larger particles (3-10 µm) throughout the patient room(s). Computational analyses were used to validate the experimental results, and, to further quantify the effect of ventilation rate on exhaust and deposition removal in patient rooms as well as other particle transport phenomena. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  15. Employment status and use of respiratory protection among metalworkers, solderers and welders

    PubMed Central

    Mirabelli, Maria C; Zock, Jan‐Paul; Plana, Estel; Benke, Geza; Kromhout, Hans; Norbäck, Dan; Olivieri, Mario; Radon, Katja; Villani, Simona; Kogevinas, Manolis

    2007-01-01

    Objectives Reported associations of self‐employment with occupational injury and cerebrovascular disease suggest that worker safety and health precautions may vary by occupational status. The authors assessed the extent to which use of respiratory protection and ventilation equipment is associated with self‐employed versus employee status among adults in an international study. Methods The European Community Respiratory Health Survey II (ECRHS II) is a follow‐up study conducted in a population‐based random sample of adult ECRHS I participants. Men and women enrolled in the ECRHS II completed interviewer‐administered questionnaires to provide information about their occupational status and job history during the 9‐year ECRHS follow‐up period. Respondents in selected occupational groups completed supplemental questionnaires about their jobs and use of respiratory protection and ventilation equipment on‐the‐job. The authors assessed self‐reported use of respiratory and ventilation equipment among 72 self‐employed and 371 employed adults in metalworking, soldering and welding occupations. Results Local exhaust ventilation (fixed extraction: OR 0.37, 95% CI 0.17 to 0.80; mobile extraction: OR 0.23, 95% CI 0.09 to 0.60; on‐tool extraction: OR 0.39, 95% CI 0.18 to 0.88) was reported less frequently among self‐employed respondents than among employed respondents. The magnitude of the negative association between self‐employment status and any of the three types of local exhaust ventilation was not attenuated by adjustment for duration of work per day or week or asthma and/or wheezing symptoms. Respiratory protection was not associated with employment status in these data. Conclusions More limited use of local exhaust ventilation among self‐employed workers compared to employees suggests the need to promote occupational safety among self‐employed workers. PMID:17387135

  16. Assessment of the LV-C2 Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.

    2015-09-01

    This document reports on a series of tests conducted to assess the proposed air sampling location for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) C2V (LV-C2) exhaust stack with respect to the applicable criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probemore » to extract a sample that represents the effluent stream. The tests were conducted on the LV-C2 scale model system. Based on the scale model tests, the location proposed for the air sampling probe in the scale model stack meets the requirements of the ANSI/HPS N13.1-1999 standard for velocity uniformity, flow angle, gas tracer and particle tracer uniformity. Additional velocity uniformity and flow angle tests on the actual stack will be necessary during cold startup to confirm the validity of the scale model results in representing the actual stack.« less

  17. A Low-Cost, Effective, Fumes Exhaust System.

    ERIC Educational Resources Information Center

    Jacobs, C. O.

    1979-01-01

    Discusses the importance of avoiding welding fumes. The sources of these fumes are presented in a table. Criticizes currently used ventilation systems and reviews the Occupational Safety and Health Act requirements. Describes a low-cost exhaust system developed for agricultural mechanics laboratories. (LRA)

  18. View forward from secondary bridge; note stack for venting after ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View forward from secondary bridge; note stack for venting after boilers, ventilators, davits, searchlights on port and starboard stanchions and ship's pulling boats; skylight at lower center provides light to engine room. (p30) - USS Olympia, Penn's Landing, 211 South Columbus Boulevard, Philadelphia, Philadelphia County, PA

  19. Cell module and fuel conditioner

    NASA Technical Reports Server (NTRS)

    Hoover, D. Q., Jr.

    1981-01-01

    The results of the completed tests on Stack 561 and the on-going tests of 562 (23 cell stacks of the MK-1 and M-2 designs respectively) are reported and their performance is compared. Results of the on-going endurance test of Stack 560 (5 cell, MK-2) are reported. Plans for fabrication of Stacks 563 and 564 (23 cell stacks of the MK-1 and MK-2 design) are summarized. Results of the burner tests are given. Excellent performance was achieved on simulated anode exhaust gas over very wide load and air/fuel ranges.

  20. System design description for portable 1,000 CFM exhauster Skids POR-007/Skid E and POR-008/Skid F

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, O.D.

    1998-07-25

    The primary purpose of the two 1,000 CFM Exhauster Skids, POR-007-SKID E and POR-008-SKID F, is to provide backup to the waste tank primary ventilation systems for tanks 241-C-106 and 241-AY-102, and the AY-102 annulus in the event of a failure during the sluicing of tank 241-C-106 and subsequent transfer of sluiced waste to 241-AY-102. This redundancy is required since both of the tank ventilation systems have been declared as Safety Class systems.

  1. Recent Upgrades at the Safety and Tritium Applied Research Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cadwallader, Lee Charles; Merrill, Brad Johnson; Stewart, Dean Andrew

    This paper gives a brief overview of the Safety and Tritium Applied Research (STAR) facility operated by the Fusion Safety Program (FSP) at the Idaho National Laboratory (INL). FSP researchers use the STAR facility to carry out experiments in tritium permeation and retention in various fusion materials, including wall armor tile materials. FSP researchers also perform other experimentation as well to support safety assessment in fusion development. This lab, in its present two-building configuration, has been in operation for over ten years. The main experiments at STAR are briefly described. This paper discusses recent work to enhance personnel safety atmore » the facility. The STAR facility is a Department of Energy less than hazard category 3 facility; the personnel safety approach calls for ventilation and tritium monitoring for radiation protection. The tritium areas of STAR have about 4 to 12 air changes per hour, with air flow being once through and then routed to the facility vent stack. Additional radiation monitoring has been installed to read the laboratory room air where experiments with tritium are conducted. These ion chambers and bubblers are used to verify that no significant tritium concentrations are present in the experiment rooms. Standby electrical power has been added to the facility exhaust blower so that proper ventilation will now operate during commercial power outages as well as the real-time tritium air monitors.« less

  2. Compressor discharge bleed air circuit in gas turbine plants and related method

    DOEpatents

    Anand, Ashok Kumar; Berrahou, Philip Fadhel; Jandrisevits, Michael

    2002-01-01

    A gas turbine system that includes a compressor, a turbine component and a load, wherein fuel and compressor discharge bleed air are supplied to a combustor and gaseous products of combustion are introduced into the turbine component and subsequently exhausted to atmosphere. A compressor discharge bleed air circuit removes bleed air from the compressor and supplies one portion of the bleed air to the combustor and another portion of the compressor discharge bleed air to an exhaust stack of the turbine component in a single cycle system, or to a heat recovery steam generator in a combined cycle system. In both systems, the bleed air diverted from the combustor may be expanded in an air expander to reduce pressure upstream of the exhaust stack or heat recovery steam generator.

  3. Compressor discharge bleed air circuit in gas turbine plants and related method

    DOEpatents

    Anand, Ashok Kumar [Niskayuna, NY; Berrahou, Philip Fadhel [Latham, NY; Jandrisevits, Michael [Clifton Park, NY

    2003-04-08

    A gas turbine system that includes a compressor, a turbine component and a load, wherein fuel and compressor discharge bleed air are supplied to a combustor and gaseous products of combustion are introduced into the turbine component and subsequently exhausted to atmosphere. A compressor discharge bleed air circuit removes bleed air from the compressor and supplies one portion of the bleed air to the combustor and another portion of the compressor discharge bleed air to an exhaust stack of the turbine component in a single cycle system, or to a heat recovery steam generator in a combined cycle system. In both systems, the bleed air diverted from the combustor may be expanded in an air expander to reduce pressure upstream of the exhaust stack or heat recovery steam generator.

  4. 40 CFR 86.004-25 - Maintenance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... its associated sensors (including oxygen sensor if installed) and actuators. (D) Exhaust gas..., and for 1985 and Later Model Year New Gasoline Fueled, Natural Gas-Fueled, Liquefied Petroleum Gas... ventilation valve. (B) Emission-related hoses and tubes. (C) Ignition wires. (D) Idle mixture. (E) Exhaust gas...

  5. 40 CFR 86.004-25 - Maintenance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... its associated sensors (including oxygen sensor if installed) and actuators. (D) Exhaust gas..., and for 1985 and Later Model Year New Gasoline Fueled, Natural Gas-Fueled, Liquefied Petroleum Gas... ventilation valve. (B) Emission-related hoses and tubes. (C) Ignition wires. (D) Idle mixture. (E) Exhaust gas...

  6. Bacterial dispersion in relation to operating room clothing.

    PubMed Central

    Whyte, W.; Vesley, D.; Hodgson, R.

    1976-01-01

    The effect of operating clothing on the dispersal of bacterial particles from the wearers was studied in a dispersal chamber. A comparison was made of six gowns as well as four types of trousers. The gowns were of three basic types, namely a conventional cotton type, disposable types made of non-woven fabric and those of the total-body exhaust system (Charnley type). The dispersal chamber could simulate conditions as expected both in down-flow unidirectional ultra-clean systems and in a conventional turbulent plenum-ventilated system. It was found that the disposable gowns would reduce the dispersal rate by about 30% in the simulated conventionally ventilated system and about 65% in the laminar flow system. The total-body exhaust system (Charnley) would reduce the count by 10-fold in the conventional ventilated system and by 66-fold in the laminar-flow system. The poor performance of the gowns in conventionally ventilated systems was caused by the dispersal of bacterial particles from underneath the gown (about 80%). This was not reduced by the disposable gown and only partially by the Charnley type. This small drop would be further decreased in a conventionally ventilated operating-room as only scrubbed staff would wear the gown. In order to overcome this poor performance in conventionally ventilated operating-rooms impervious trousers would be required. Four types were studied and it was demonstrated that those made either from Ventile or non-woven fabric would reduce the bacterial dispersion fourfold. As these tests had been carried out in an artificial environment checks were carried out in the unidirectional-flow operating-room during total-hip arthroplasty. This was done by comparing conventional cotton gowns with non-woven gowns and total-body exhaust gowns. The results showed good correlation between the operating room and the chamber with the non-woven fabric gown but the total-body exhaust system did not perform as well in the operating room (12-fold compared to 66-fold) the difference being possibly due to the contribution from the patient. However, as this comparison was that which would be most open to influence from other variables confidence could be placed on the chamber test results. Values were also obtained for the total number of bacterial particles dispersed by persons during a standard exercise wearing different clothing. This count was dependent on the clothing worn but a median count of between 1000 and 1500 bacterial particles/min. would be expected when conventional clothing was worn, with a range of between 300 and 19,000. This count could be reduced to about 100/min. if a total-body exhaust suit was worn (range 30-400). PMID:778258

  7. Healthy Efficient New Gas Homes (HENGH) Pilot Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, Wanyu R.; Maddalena, Randy L; Stratton, Chris

    The Healthy Efficient New Gas Homes (HENGH) is a field study that will collect data on ventilation systems and indoor air quality (IAQ) in new California homes that were built to 2008 Title 24 standards. A pilot test was performed to help inform the most time and cost effective approaches to measuring IAQ in the 100 test homes that will be recruited for this study. Two occupied, single-family detached homes built to 2008 Title 24 participated in the pilot test. One of the test homes uses exhaust-only ventilation provided by a continuous exhaust fan in the laundry room. The othermore » home uses supply air for ventilation. Measurements of IAQ were collected for two weeks. Time-resolved concentrations of particulate matter (PM), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde were measured. Measurements of IAQ also included time-integrated concentrations of volatile organic compounds (VOCs), volatile aldehydes, and NO2. Three perfluorocarbon tracers (PFTs) were used to estimate the dilution rate of an indoor emitted air contaminant in the two pilot test homes. Diagnostic tests were performed to measure envelope air leakage, duct leakage, and airflow of range hood, exhaust fans, and clothes dryer vent when accessible. Occupant activities, such as cooking, use of range hood and exhaust fans, were monitored using various data loggers. This document describes results of the pilot test.« less

  8. Odor control in swine buildings: recycle flush vs. automated scraper

    USDA-ARS?s Scientific Manuscript database

    A research project was conducted to compare odor concentrations in exhaust of traditional flush barns and barns equipped with automated scrapers. The study was conducted at commercial tunnel-ventilated swine barns in northwest Missouri. Odor samples were collected from the barn exhaust in polyvinyl ...

  9. 9 CFR 3.65 - Terminal facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., or air conditioning and may be ventilated or air circulated by means of fans, blowers, or an air conditioning system so as to minimize drafts, odors, and moisture condensation. Auxiliary ventilation, such as exhaust fans and vents or fans or blowers or air conditioning shall be used for any animal holding area...

  10. 29 CFR 1915.32 - Toxic cleaning solvents.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... space. (2) Either natural ventilation or mechanical exhaust ventilation shall be used to remove the vapor at the source and to dilute the concentration of vapors in the working space to a concentration which is safe for the entire work period. (3) Employees shall be protected against toxic vapors by...

  11. Explosive demolition of K East Reactor Stack

    ScienceCinema

    None

    2017-12-09

    Using $420,000 in Recovery Act funds, the Department of Energy and contractor CH2M HILL Plateau Remediation Company topped off four months of preparations when they safely demolished the exhaust stack at the K East Reactor and equipment inside the reactor building on July 23, 2010.

  12. Operating and maintaining your heat recovery ventilator (HRV) -- Revised edition. Home heating and cooling series, Number 8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Heat recovery ventilators (HRVs) differ from other mechanical ventilation devices by their ability to exchange heat between supply and exhaust air streams, which reduces the cost of heating or cooling fresh air. This booklet discusses the need for mechanical ventilation in conventional and energy-efficient homes, an explains the components of a HRV system, how to operate and maintain the system, and how to solve operating problems. A maintenance chart and schedule and a HRV troubleshooting guide are included.

  13. The transmission characteristics of indoor particles under different ventilation conditions

    NASA Astrophysics Data System (ADS)

    Lv, Yang; Wang, Haifeng; Wei, Shanshan

    2017-11-01

    In modern society, ventilation is an important method for removing indoor particles. This study applies the parameter of attenuation index to analyze the effect of the removal of indoor particles in the two typical ventilation strategies called ceiling exhaust and slit exhaust strategy. Experiment was conducted in a chamber and riboflavin particles were used as the indoor particles source, instantaneous microbial detection (IMD) used to measure the particulate concentration. Conclusions can be found that air exchange rate is an important factor affecting the indoor particle concentration distribution. In the process of indoor free settling(air exchange rate is 0 h-1), the deposition rate were 0.086 h-1, 0.122 h-1, 0.173 h-1 for the particles of 0.5-1.0 μm, 1.0-3.0μm and 3.0-5.0 μm. When the air exchange rate increased to 2.5 h-1, the differences in the attenuation index is significant. There was also a significant linear relationship between air exchange rate and attenuation index. Furthermore, the effect of the slit exhaust strategy on the removal of coarse particles is more remarkable as the increasing air exchange rate.

  14. Laboratory Ventilation and Safety.

    ERIC Educational Resources Information Center

    Steere, Norman V.

    1965-01-01

    In order to meet the needs of both safety and economy, laboratory ventilation systems must effectively remove air-borne toxic and flammable materials and at the same time exhaust a minimum volume of air. Laboratory hoods are the most commonly used means of removing gases, dusts, mists, vapors, and fumed from laboratory operations. To be effective,…

  15. 30 CFR 75.326 - Mean entry air velocity.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Mean entry air velocity. 75.326 Section 75.326... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.326 Mean entry air velocity. In exhausting face ventilation systems, the mean entry air velocity shall be at least 60 feet per minute...

  16. 30 CFR 75.326 - Mean entry air velocity.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Mean entry air velocity. 75.326 Section 75.326... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.326 Mean entry air velocity. In exhausting face ventilation systems, the mean entry air velocity shall be at least 60 feet per minute...

  17. 30 CFR 75.371 - Mine ventilation plan; contents.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (see § 75.325(a)(3)). (k) The minimum mean entry air velocity in exhausting face ventilation systems where coal is being cut, mined, drilled for blasting, or loaded, if the velocity will be less than 60... loaded, where at least 60 feet per minute or some other minimum mean entry air velocity will be...

  18. 30 CFR 75.371 - Mine ventilation plan; contents.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (see § 75.325(a)(3)). (k) The minimum mean entry air velocity in exhausting face ventilation systems where coal is being cut, mined, drilled for blasting, or loaded, if the velocity will be less than 60... loaded, where at least 60 feet per minute or some other minimum mean entry air velocity will be...

  19. 30 CFR 75.371 - Mine ventilation plan; contents.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (see § 75.325(a)(3)). (k) The minimum mean entry air velocity in exhausting face ventilation systems where coal is being cut, mined, drilled for blasting, or loaded, if the velocity will be less than 60... loaded, where at least 60 feet per minute or some other minimum mean entry air velocity will be...

  20. Compliance Testing of Grissom AFB Central Heating Plant Coal-Fired Boilers 3 and 5, Grissom AFB, Indiana

    DTIC Science & Technology

    1988-06-01

    common breeching and can be routed to the wet-scrubber or to a bypass stack. The scrubber is a double-alkali flue - gas desulfurization system using soda...Illustrations Figure Title Page 1 View of Scrubber and Bypass Stacks 3 2 Scrubber Stacks 4 3 Bypass Stack 5 4 Flue Gas Flow Diagram 6 5 ORSAT Sampling...of gases and to provide a positive static pressure at flue gas exhaust discharge points. The ash system pneumatically removes ash from bottom-ash

  1. Infrared suppressor effect on T63 turboshaft engine performance

    NASA Technical Reports Server (NTRS)

    Bailey, E. E.; Civinskas, K. C.; Walker, C. L.

    1978-01-01

    Tests were conducted to determine if there are performance penalties associated with the installation of infrared (IR) suppressors on the T63-A-700 turboshaft engine. The testing was done in a sea-level, static test cell. The same engine (A-E402808 B) was run with the standard OH-58 aircraft exhaust stacks and with the ejector-type IR suppressors in order to make a valid comparison. Repeatability of the test results for the two configurations was verified by rerunning the conditions over a period of days. Test results showed no measurable difference in performance between the standard exhaust stacks and the IR suppressors.

  2. Development of naval diesel engine duty cycles for air exhaust emission environmental impact analysis. Master's thesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Markle, S.P.

    1994-05-01

    A strategy for testing naval diesel engines for exhaust emissions was developed. A survey of existing international and national standard diesel engine duty cycles was conducted. All were found to be inadequate for testing and certification of engine exhaust emissions from naval diesel powered ships. Naval ship data covering 11,500 hours of engine operation of four U.S. Navy LSD 41 Class amphibious ships was analyzed to develop a 27 point class operating profile. A procedure combining ship hull form characteristics, ship propulsion plant parameters, and ship operating profile was detailed to derive an 11-Mode duty cycle representative for testing LSDmore » 41 Class propulsion diesel engines. A similar procedure was followed for ship service diesel engines. Comparisons with industry accepted duty cycles were conducted using exhaust emission contour plots for the Colt-Pielstick PC-4B diesel engines. Results showed the 11-Mode LSD 41 Class Duty Cycle best predicted ship propulsion engine emissions compared to the 27 point operating profile propeller curve. The procedure was applied to T-AO 187 Class with similar results. The application of civilian industry standards to measure naval diesel ship propulsion engine exhaust emissions was found to be inadequate. Engine exhaust flow chemistry post turbocharger was investigated using the SANDIA Lab computer tool CHEMKIN. Results showed oxidation and reduction reactions within exhaust gases are quenched in the exhaust stack. Since the exhaust stream in the stack is unreactive, emission sampling may be performed where most convenient. A proposed emission measurement scheme for LSD 41 Class ships was presented.« less

  3. Micro-scale pollution mechanism of dust diffusion in a blasting driving face based on CFD-DEM coupled model.

    PubMed

    Yu, Haiming; Cheng, Weimin; Xie, Yao; Peng, Huitian

    2018-05-23

    In order to investigate the diffuse pollution mechanisms of high-concentration dusts in the blasting driving face, the airflow-dust coupled model was constructed based on CFD-DEM coupled model; the diffusion rules of the dusts with different diameters at microscopic scale were analyzed in combination with the field measured results. The simulation results demonstrate that single-exhaust ventilation exhibited more favorable dust suppression performance than single-forced ventilation. Under single-exhaust ventilation condition, the motion trajectories of the dusts with the diameter smaller than 20 μm were close to the airflow streamline and these dusts were mainly distributed near the footway walls; by contrast, under single-forced ventilation condition, the motion trajectories of the dust particles with a diameter range of 20~40 μm were close to the airflow streamlines, and a large number of dusts with the diameter smaller than 20 μm accumulated in the regions 5 m and 17~25 m away from the head-on section. Moreover, under the single-exhaust ventilation, the relationship between dust diameter D and negative-pressured-induced dust emission ratio P can be expressed as P = - 25.03ln(D) + 110.39, and the dust emission ratio was up to 74.36% for 7-μm dusts, and the path-dependent settling behaviors of the dusts mainly occurred around the head-on section; under single-forced ventilation condition, the z value of the dusts with the diameter over 20 μm decreased and the dusts with a diameter smaller than 7 μm are particularly harmful to human health, but their settling ratios were below 22.36%. Graphical abstract The airflow-dust CFD-DEM coupling model was established. The numerical simulation results were verified. The migration laws of airflow field were obtained in a blasting driving face. The diffusion laws of dusts were obtained after blasting.

  4. Performance of particulate containment at nanotechnology workplaces

    NASA Astrophysics Data System (ADS)

    Lo, Li-Ming; Tsai, Candace S.-J.; Dunn, Kevin H.; Hammond, Duane; Marlow, David; Topmiller, Jennifer; Ellenbecker, Michael

    2015-11-01

    The evaluation of engineering controls for the production or use of carbon nanotubes (CNTs) was investigated at two facilities. These control assessments are necessary to evaluate the current status of control performance and to develop proper control strategies for these workplaces. The control systems evaluated in these studies included ventilated enclosures, exterior hoods, and exhaust filtration systems. Activity-based monitoring with direct-reading instruments and filter sampling for microscopy analysis were used to evaluate the effectiveness of control measures at study sites. Our study results showed that weighing CNTs inside the biological safety cabinet can have a 37 % reduction on the particle concentration in the worker's breathing zone, and produce a 42 % lower area concentration outside the enclosure. The ventilated enclosures used to reduce fugitive emissions from the production furnaces exhibited good containment characteristics when closed, but they failed to contain emissions effectively when opened during product removal/harvesting. The exhaust filtration systems employed for exhausting these ventilated enclosures did not provide promised collection efficiencies for removing engineered nanomaterials from furnace exhaust. The exterior hoods were found to be a challenge for controlling emissions from machining nanocomposites: the downdraft hood effectively contained and removed particles released from the manual cutting process, but using the canopy hood for powered cutting of nanocomposites created 15-20 % higher ultrafine (<500 nm) particle concentrations at the source and at the worker's breathing zone. The microscopy analysis showed that CNTs can only be found at production sources but not at the worker breathing zones during the tasks monitored.

  5. Field evaluation of an engineering control for respirable crystalline silica exposures during mortar removal.

    PubMed

    Collingwood, Scott; Heitbrink, William A

    2007-11-01

    During mortar removal with a right angle grinder, a building renovation process known as "tuck pointing," worker exposures to respirable crystalline silica can be as high as 5 mg/m(3), 100 times the recommended exposure limit developed by the National Institute for Occupational Safety and Health. To reduce the risk of silicosis among these workers, a vacuum cleaner can be used to exhaust 80 ft(3)/min (2.26 m(3)/min) from a hood mounted on the grinder. Field trials examined the ability of vacuum cleaners to maintain adequate exhaust ventilation rates and measure exposure outcomes when using this engineering control. These field trials involved task-based exposure measurement of respirable dust and crystalline silica exposures during mortar removal. These measurements were compared with published exposure data. Vacuum cleaner airflows were obtained by measuring and digitally logging vacuum cleaner static pressure at the inlet to the vacuum cleaner motor. Static pressures were converted to airflows based on experimentally determined fan curves. In two cases, video exposure monitoring was conducted to study the relationship between worker activities and dust exposure. Worker activities were video taped concurrent with aerosol photometer measurement of dust exposure and vacuum cleaner static pressure as a measure of airflow. During these field trials, respirable crystalline silica exposures for 22 samples had a geometric mean of 0.06 mg/m(3) and a range of less than 0.01 to 0.86 mg/m(3). For three other studies, respirable crystalline silica exposures during mortar removal have a geometric means of 1.1 to 0.35. Although this field study documented noticeably less exposure to crystalline silica, video exposure monitoring found that the local exhaust ventilation provided incomplete dust control due to low exhaust flow rates, certain work practices, and missing mortar. Vacuum cleaner airflow decrease had a range of 3 to 0.4 ft(3)/min (0.08 to 0.01 m(3)/sec(2)) over a range of vacuum cleaners, hose diameters, and hose lengths. To control worker exposure to respirable crystalline silica, local exhaust ventilation needs to be incorporated into a comprehensive silica control program that includes respiratory protection, worker training, and local exhaust ventilation.

  6. Effect of ship-stack effluents on cloud reflectivity

    NASA Technical Reports Server (NTRS)

    Coakley, James A., Jr.; Bernstein, Robert L.; Durkee, Philip A.

    1987-01-01

    Under stable meteorological conditions the effect of ship-stack exhaust on overlying clouds was detected in daytime satellite images as an enhancement in cloud reflectivity at 3.7 micrometers. The exhaust is a source of cloud-condensation nuclei that increases the number of cloud droplets while reducing droplet size. This reduction in droplet size causes the reflectivity at 3.7 micrometers to be greater than the levels for nearby noncontaminated clouds of similar physical characteristics. The increase in droplet number causes the reflectivity at 0.63 micrometer to be significantly higher for the contaminated clouds despite the likelihood that the exhaust is a source of particles that absorb at visible wavelengths. The effect of aerosols on cloud reflectivity is expected to have a larger influence on the earth's albedo than that due to the direct scattering and absorption of sunlight by the aerosols alone.

  7. 54. VIEW OF ROASTER ADDITION FROM SOUTHEAST. SHOWS ELEVATOR/ORE BIN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    54. VIEW OF ROASTER ADDITION FROM SOUTHEAST. SHOWS ELEVATOR/ORE BIN ADDITION ON LEFT WITH BASE OF EXHAUST STACK, PORTION OF TOPPLED STACK ON LOWER RIGHT IN VIEW, AND UPPER TAILINGS POND BEYOND. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  8. COST EFFECTIVE VOC EMISSION CONTROL STARTEGIES FOR MILITARY, AEROSPACE,AND INDUSTRIAL PAINT SPRAY BOOTH OPERATIONS: COMBINING IMPROVED VENTILATION SYSTEMS WITH INNOVATIVE, LOW COST EMISSION CONTROL TECHNOLOGIES

    EPA Science Inventory

    The paper describes a full-scale demonstration program in which several paint booths were modified for recirculation ventilation; the booth exhaust streams are vented to an innovative volatile organic compound (VOC) emission control system having extremely low operating costs. ...

  9. Assessment of the National Research Universal Reactor Proposed New Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.

    2016-02-29

    This document reports on a series of tests conducted to assess the proposed air sampling location for the National Research Universal reactor (NRU) complex exhaust stack, located in Chalk River, Ontario, Canada, with respect to the applicable criteria regarding the placement of an air sampling probe. Due to the age of the equipment in the existing monitoring system, and the increasing difficulty in acquiring replacement parts to maintain this equipment, a more up-to-date system is planned to replace the current effluent monitoring system, and a new monitoring location has been proposed. The new sampling probe should be located within themore » exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The internal Pacific Northwest National Laboratory (PNNL) project for this task was 65167, Atomic Energy Canada Ltd. Chalk River Effluent Duct Flow Qualification. The testing described in this document was guided by the Test Plan: Testing of the NRU Stack Air Sampling Position (TP-STMON-032).« less

  10. Experimental Determination of Exhaust Gas Thrust, Special Report

    NASA Technical Reports Server (NTRS)

    Pinkel, Benjamin; Voss, Fred

    1940-01-01

    This investigation presents the results of tests made on a radial engine to determine the thrust that can be obtained from the exhaust gas when discharged from separate stacks and when discharged from the collector ring with various discharge nozzles. The engine was provided with a propeller to absorb the power and was mounted on a test stand equipped with scales for measuring the thrust and engine torque. The results indicate that at full open throttle at sea level, for the engine tested, a gain in thrust horsepower of 18 percent using separate stacks, and 9.5 percent using a collector ring and discharge nozzle, can be expected at an air speed of 550 miles per hour.

  11. Using a Ventilation Controller to Optimize Residential Passive Ventilation For Energy and Indoor Air Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turner, William; Walker, Iain

    One way to reduce the energy impact of providing residential ventilation is to use passive and hybrid systems. However, these passive and hybrid (sometimes called mixed-mode) systems must still meet chronic and acute health standards for ventilation. This study uses a computer simulation approach to examine the energy and indoor air quality (IAQ) implications of passive and hybrid ventilation systems, in 16 California climate zones. Both uncontrolled and flow controlled passive stacks are assessed. A new hybrid ventilation system is outlined that uses an intelligent ventilation controller to minimise energy use, while ensuring chronic and acute IAQ standards are met.more » ASHRAE Standard 62.2-2010 – the United States standard for residential ventilation - is used as the chronic standard, and exposure limits for PM 2.5, formaldehyde and NO 2 are used as the acute standards.The results show that controlled passive ventilation and hybrid ventilation can be used in homes to provide equivalent IAQ to continuous mechanical ventilation, for less use of energy.« less

  12. Computational fluid dynamics study on the influence of an alternate ventilation configuration on the possible flow path of infectious cough aerosols in a mock airborne infection isolation room.

    PubMed

    Thatiparti, Deepthi Sharan; Ghia, Urmila; Mead, Kenneth R

    2016-01-01

    When infectious epidemics occur, they can be perpetuated within health care settings, potentially resulting in severe health care workforce absenteeism, morbidity, mortality, and economic losses. The ventilation system configuration of an airborne infection isolation room is one factor that can play a role in protecting health care workers from infectious patient bioaerosols. Though commonly associated with airborne infectious diseases, the airborne infection isolation room design can also impact other transmission routes such as short-range airborne as well as fomite and contact transmission routes that are impacted by contagion concentration and recirculation. This article presents a computational fluid dynamics study on the influence of the ventilation configuration on the possible flow path of bioaerosol dispersal behavior in a mock airborne infection isolation room. At first, a mock airborne infection isolation room was modeled that has the room geometry and layout, ventilation parameters, and pressurization corresponding to that of a traditional ceiling-mounted ventilation arrangement observed in existing hospitals. An alternate ventilation configuration was then modeled to retain the linear supply diffuser in the original mock airborne infection isolation room but interchanging the square supply and exhaust locations to place the exhaust closer to the patient source and allow clean air from supply vents to flow in clean-to-dirty flow paths, originating in uncontaminated parts of the room prior to entering the contaminated patient's air space. The modeled alternate airborne infection isolation room ventilation rate was 12 air changes per hour. Two human breathing models were used to simulate a source patient and a receiving health care worker. A patient cough cycle was introduced into the simulation, and the airborne infection dispersal was tracked in time using a multi-phase flow simulation approach. The results from the alternate configuration revealed that the cough aerosols were pulled by the exhaust vent without encountering the health care worker by 0.93 s after patient coughs and the particles were controlled as the aerosols' flow path was uninterrupted by an air particle streamline from patient to the ceiling exhaust venting out cough aerosols. However, not all the aerosols were vented out of the room. The remaining cough aerosols entered the health care worker's breathing zone by 0.98 s. This resulted in one of the critical stages in terms of the health care worker's exposure to airborne virus and presented the opportunity for the health care worker to suffer adverse health effects from the inhalation of cough aerosols. Within 2 s, the cough aerosols reentered and recirculated within the patient and health care worker's surroundings resulting in pockets of old contaminated air. By this time, coalescence losses decreased as the aerosol were no longer in very close proximity and their movement was primarily influenced by the airborne infection isolation room airflow patterns. In the patient and health care worker's area away from the supply, the fresh air supply failed to reach this part of the room to quickly dilute the cough aerosol concentration. The exhaust was also found to have minimal effect upon cough aerosol removal, except for those areas with high exhaust velocities, very close to the exhaust grill. Within 5-20 s after a patient's cough, the aerosols tended to break up to form smaller sized aerosols of less than one micron diameter. They remained airborne and entrained back into the supply air stream, spreading into the entire room. The suspended aerosols resulted in the floating time of more than 21 s in the room due to one cough cycle. The duration of airborne contagion in the room and its prolonged exposure to the health care worker is likely to happen due to successive coughing cycles. Hence, the evaluated alternate airborne infection isolation room is not effective in removing at least 38% particles exposed to health care worker within the first second of a patient's cough.

  13. Impact of varying area of polluting surface materials on perceived air quality.

    PubMed

    Sakr, W; Knudsen, H N; Gunnarsen, L; Haghighat, F

    2003-06-01

    A laboratory study was performed to investigate the impact of the concentration of pollutants in the air on emissions from building materials. Building materials were placed in ventilated test chambers. The experimental set-up allowed the concentration of pollution in the exhaust air to be changed either by diluting exhaust air with clean air (changing the dilution factor) or by varying the area of the material inside the chamber when keeping the ventilation rate constant (changing the area factor). Four different building materials and three combinations of two or three building materials were studied in ventilated small-scale test chambers. Each individual material and three of their combinations were examined at four different dilution factors and four different area factors. An untrained panel of 23 subjects assessed the air quality from the chambers. The results show that a certain increase in dilution improves the perceived air quality more than a similar decrease in area. The reason for this may be that the emission rate of odorous pollutants increases when the concentration in the chamber decreases. The results demonstrate that, in some cases the effect of increased ventilation on the air quality may be less than expected from a simple dilution model.

  14. Local exhaust ventilation for the control of welding fumes in the construction industry--a literature review.

    PubMed

    Flynn, Michael R; Susi, Pam

    2012-08-01

    Arc welding is a common unit operation in the construction industry, where frequent changes in location and welding position make it more difficult to control fume exposures than in industries where fixed locations are the norm. Welders may be exposed to a variety of toxic airborne contaminants including manganese (Mn) and hexavalent chromium (CrVI). Local exhaust ventilation (LEV) is a well-known engineering control for welding fumes but has not been adopted widely in the construction industry. This literature review presents data on the performance of a variety of LEV systems for welding fume control from the construction (five references), shipyard (five references), and other industries. The studies indicate that LEV can reduce fume exposures to total particulate, Mn, and CrVI to levels below currently relevant standards. Field studies suggest that 40-50% or more reduction in exposure is possible with portable or fixed LEV systems relative to natural ventilation but that correct positioning of the hood and adequate exhaust flow rates are essential. Successful implementation of extraction guns for gas metal arc welding (GMAW) and flux core arc welding has been demonstrated, indicating that a successful balance between extraction airflow and shielding gas requirements is possible. Work practices are an important part of achieving successful control of fume exposures; in particular, positioning the hood close to the arc, checking exhaust flow rates, and avoiding the plume. Further research is needed on hood size effects for controlling welding fume with portable LEV systems and identifying and overcoming barriers to LEV use in construction.

  15. Performance of Particulate Containment at Nanotechnology Workplaces

    PubMed Central

    Lo, Li-Ming; Tsai, Candace S.-J.; Dunn, Kevin H.; Hammond, Duane; Marlow, David; Topmiller, Jennifer; Ellenbecker, Michael

    2015-01-01

    The evaluation of engineering controls for the production or use of carbon nanotubes (CNTs) was investigated at two facilities. These controls assessments are necessary to evaluate the current status of control performance and to develop proper control strategies for these workplaces. The control systems evaluated in these studies included ventilated enclosures, exterior hoods, and exhaust filtration systems. Activity-based monitoring with direct-reading instruments and filter sampling for microscopy analysis were used to evaluate the effectiveness of control measures at study sites. Our study results showed that weighing CNTs inside the biological safety cabinet can have a 37% reduction on the particle concentration in the worker’s breathing zone, and produce a 42% lower area concentration outside the enclosure. The ventilated enclosures used to reduce fugitive emissions from the production furnaces exhibited good containment characteristics when closed, but they failed to contain emissions effectively when opened during product removal/harvesting. The exhaust filtration systems employed for exhausting these ventilated enclosures did not provide promised collection efficiencies for removing engineered nanomaterials from furnace exhaust. The exterior hoods were found to be a challenge for controlling emissions from machining nanocomposites: the downdraft hood effectively contained and removed particles released from the manual cutting process, but using the canopy hood for powered cutting of nanocomposites created 15%–20% higher ultrafine (<500 nm) particle concentrations at the source and at the worker’s breathing zone. The microscopy analysis showed that CNTs can only be found at production sources but not at the worker breathing zones during the tasks monitored. PMID:26705393

  16. Thermal energy recycling fuel cell arrangement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanrahan, Paul R.

    An example fuel cell arrangement includes a fuel cell stack configured to receive a supply fluid and to provide an exhaust fluid that has more thermal energy than the supply fluid. The arrangement also includes an ejector and a heat exchanger. The ejector is configured to direct at least some of the exhaust fluid into the supply fluid. The heat exchanger is configured to increase thermal energy in the supply fluid using at least some of the exhaust fluid that was not directed into the supply fluid.

  17. Air temperature gradient in large industrial hall

    NASA Astrophysics Data System (ADS)

    Karpuk, Michał; Pełech, Aleksander; Przydróżny, Edward; Walaszczyk, Juliusz; Szczęśniak, Sylwia

    2017-11-01

    In the rooms with dominant sensible heat load, volume airflow depends on many factors incl. pre-established temperature difference between exhaust and supply airflow. As the temperature difference is getting higher, airflow volume drops down, consequently, the cost of AHU is reduced. In high industrial halls with air exhaust grids located under the ceiling additional temperature gradient above working zone should be taken into consideration. In this regard, experimental research of the vertical air temperature gradient in high industrial halls were carried out for the case of mixing ventilation system The paper presents the results of air temperature distribution measurements in high technological hall (mechanically ventilated) under significant sensible heat load conditions. The supply airflow was delivered to the hall with the help of the swirl diffusers while exhaust grids were located under the hall ceiling. Basing on the air temperature distribution measurements performed on the seven pre-established levels, air temperature gradient in the area between 2.0 and 7.0 m above the floor was calculated and analysed.

  18. DEMONSTRATION OF SPLIT-FLOW VENTILATION AND RECIR CULATION AS FLOW-REDUCTION METHODS IN AN AIR FORCE PAINT SPRAY BOOTH - VOLUME I. MAIN REPORT, APPENDICES A-C

    EPA Science Inventory

    During a series of painting operations in a horizontal-flow paint spray booth at Travis AFB, CA, baseline concentrations of four classes of toxic airborne pollutants were measured at 24 locations across a plane immediately forward of the exhaust filters, in the exhaust duct, and ...

  19. DEMONSTRATION OF SPLIT-FLOW VENTILATION AND RECIRCULATION AS FLOW-REDUCTION METHODS IN AN AIR FORCE PAINT SPRAY BOOTH - VOLUME II. APPENDICES D-J

    EPA Science Inventory

    During a series of painting operations in a horizontal-flow paint spray booth at Travis AFB, CA, baseline concentrations of four classes of toxic airborne pollutants were measured at 24 locations across a plane immediately forward of the exhaust filters, in the exhaust duct, and ...

  20. Modeling the resiliency of energy-efficient retrofits in low-income multifamily housing.

    PubMed

    Underhill, L J; Fabian, M P; Vermeer, K; Sandel, M; Adamkiewicz, G; Leibler, J H; Levy, J I

    2018-05-01

    Residential energy efficiency and ventilation retrofits (eg, building weatherization, local exhaust ventilation, HVAC filtration) can influence indoor air quality (IAQ) and occupant health, but these measures' impact varies by occupant activity. In this study, we used the multizone airflow and IAQ analysis program CONTAM to simulate the impacts of energy retrofits on indoor concentrations of PM 2.5 and NO 2 in a low-income multifamily housing complex in Boston, Massachusetts (USA). We evaluated the differential impact of residential activities, such as low- and high-emission cooking, cigarette smoking, and window opening, on IAQ across two seasons. We found that a comprehensive package of energy and ventilation retrofits was resilient to a range of occupant activities, while less holistic approaches without ventilation improvements led to increases in indoor PM 2.5 or NO 2 for some populations. In general, homes with simulated concentration increases included those with heavy cooking and no local exhaust ventilation, and smoking homes without HVAC filtration. Our analytical framework can be used to identify energy-efficient home interventions with indoor retrofit resiliency (ie, those that provide IAQ benefits regardless of occupant activity), as well as less resilient retrofits that can be coupled with behavioral interventions (eg, smoking cessation) to provide cost-effective, widespread benefits. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Characterization of biomass burning aerosols produced in the laboratory with a light-scattering aerosol mass spectrometer

    NASA Astrophysics Data System (ADS)

    Middlebrook, A. M.; Adler, G. A.; Coggon, M.; De Gouw, J. A.; Franchin, A.; Gilman, J.; Koss, A.; Krechmer, J. E.; Lamb, K.; Manfred, K.; Roberts, J. M.; Schwarz, J. P.; Sekimoto, K.; Selimovic, V.; Stockwell, C.; Wagner, N.; Warneke, C.; Washenfelder, R. A.; Womack, C.; Yokelson, R. J.; Yuan, B.

    2017-12-01

    During the 2016 NOAA FIREX project at the Missoula Fire Sciences Laboratory, small fires of known fuel type and properties were ignited to characterize their direct emissions with a large variety of new sampling methods. Two types of experiments were employed: sampling smoke directly from the exhaust stack throughout the lifecycle of the fires (stack burns) or sampling when the exhaust vent was closed to fill the room with smoke (room burns). For both types of burns, photo-oxidation chambers were at times used to mimic aging in the atmosphere. During all these experiments, we measured the non-refractory components of the smoke particles using an Aerodyne compact time-of-flight aerosol mass spectrometer (AMS) with a light scattering module and diluted the sample line as little as possible (usually by a factor of 10) without overwhelming our instrument. For the stack burns, our AMS was placed near the top of the exhaust stack to capture the composition and size distribution during the rapidly changing stages of the fires. We found that the chemical composition of the aerosols varied with fuel type and combustion conditions on time scales of a few minutes as the fuels went through different stages of heating and combustion. For the room burns, we obtained additional measurements with the light-scattering module aimed at understanding how well smoke particles are measured with the AMS, along with characterization of their physical properties. We will present a summary of our results, with connections to their relevance for constraining model treatments of fire emissions on the atmosphere.

  2. PEM fuel cell monitoring system

    DOEpatents

    Meltser, Mark Alexander; Grot, Stephen Andreas

    1998-01-01

    Method and apparatus for monitoring the performance of H.sub.2 --O.sub.2 PEM fuel cells. Outputs from a cell/stack voltage monitor and a cathode exhaust gas H.sub.2 sensor are corrected for stack operating conditions, and then compared to predetermined levels of acceptability. If certain unacceptable conditions coexist, an operator is alerted and/or corrective measures are automatically undertaken.

  3. Behavior of Mercury Emissions from a Commercial Coal-Fired Utility Boiler: TheRelationship Between Stack Speciation and Near-Field Plume Measurements

    EPA Science Inventory

    The reduction of divalent gaseous mercury (HgII) to elemental gaseous mercury (Hg0) in a commercial coal-fired power plant (CFPP)exhaust plume was investigated by simultaneous measurement in-stack and in-plume as part of a collaborative study among the U.S....

  4. Hexavalent chromium and isocyanate exposures during military aircraft painting under crossflow ventilation.

    PubMed

    Bennett, James S; Marlow, David A; Nourian, Fariba; Breay, James; Hammond, Duane

    2016-01-01

    Exposure control systems performance was investigated in an aircraft painting hangar. The ability of the ventilation system and respiratory protection program to limit worker exposures was examined through air sampling during painting of F/A-18C/D strike fighter aircraft, in four field surveys. Air velocities were measured across the supply filter, exhaust filter, and hangar midplane under crossflow ventilation. Air sampling conducted during painting process phases (wipe-down, primer spraying, and topcoat spraying) encompassed volatile organic compounds, total particulate matter, Cr[VI], metals, nitroethane, and hexamethylene diisocyanate, for two worker groups: sprayers and sprayer helpers ("hosemen"). One of six methyl ethyl ketone and two of six methyl isobutyl ketone samples exceeded the short term exposure limits of 300 and 75 ppm, with means 57 ppm and 63 ppm, respectively. All 12 Cr[VI] 8-hr time-weighted averages exceeded the recommended exposure limit of 1 µg/m3, 11 out of 12 exceeded the permissible exposure limit of 5 µg/m3, and 7 out of 12 exceeded the threshold limit value of 10 µg/m3, with means 38 µg/m3 for sprayers and 8.3 µg/m3 for hosemen. Hexamethylene diisocyanate means were 5.95 µg/m3 for sprayers and 0.645 µg/m3 for hosemen. Total reactive isocyanate group--the total of monomer and oligomer as NCO group mass--showed 6 of 15 personal samples exceeded the United Kingdom Health and Safety Executive workplace exposure limit of 20 µg/m3, with means 50.9 µg/m3 for sprayers and 7.29 µg/m3 for hosemen. Several exposure limits were exceeded, reinforcing continued use of personal protective equipment. The supply rate, 94.4 m3/s (200,000 cfm), produced a velocity of 8.58 m/s (157 fpm) at the supply filter, while the exhaust rate, 68.7 m3/s (146,000 cfm), drew 1.34 m/s (264 fpm) at the exhaust filter. Midway between supply and exhaust locations, the velocity was 0.528 m/s (104 fpm). Supply rate exceeding exhaust rate created re-circulations, turbulence, and fugitive emissions, while wasting energy. Smoke releases showing more effective ventilation here than in other aircraft painting facilities carries technical feasibility relevance.

  5. Hexavalent Chromium and Isocyanate Exposures during Military Aircraft Painting under Crossflow Ventilation

    PubMed Central

    Bennett, James S.; Marlow, David A.; Nourian, Fariba; Breay, James; Hammond, Duane

    2016-01-01

    Exposure control systems performance was investigated in an aircraft painting hangar. The ability of the ventilation system and respiratory protection program to limit worker exposures was examined through air sampling during painting of F/A-18C/D strike fighter aircraft, in four field surveys. Air velocities were measured across the supply filter, exhaust filter, and hangar midplane under crossflow ventilation. Air sampling conducted during painting process phases (wipe-down, primer spraying, and topcoat spraying) encompassed volatile organic compounds, total particulate matter, Cr[VI], metals, nitroethane, and hexamethylene diisocyanate, for two worker groups: sprayers and sprayer helpers (“hosemen”). One of six methyl ethyl ketone and two of six methyl isobutyl ketone samples exceeded the short term exposure limits of 300 and 75 ppm, with means 57 ppm and 63 ppm, respectively. All 12 Cr[VI] 8-hr time-weighted averages exceeded the recommended exposure limit of 1 µg/m3, 11 out of 12 exceeded the permissible exposure limit of 5 µg/m3, and 7 out of 12 exceeded the threshold limit value of 10 µg/m3, with means 38 µg/m3 for sprayers and 8.3 µg/m3 for hosemen. Hexamethylene diisocyanate means were 5.95 µg/m3 for sprayers and 0.645 µg/m3 for hosemen. Total reactive isocyanate group—the total of monomer and oligomer as NCO group mass—showed six of 15 personal samples exceeded the United Kingdom Health and Safety Executive workplace exposure limit of 20 µg/m3, with means 50.9 µg/m3 for sprayers and 7.29 µg/m3 for hosemen. Several exposure limits were exceeded, reinforcing continued use of personal protective equipment. The supply rate, 94.4 m3/s (200,000 cfm), produced a velocity of 8.58 m/s (157 fpm) at the supply filter, while the exhaust rate, 68.7 m3/s (146,000 cfm), drew 1.34 m/s (264 fpm) at the exhaust filter. Midway between supply and exhaust locations, the velocity was 0.528 m/s (104 fpm). Supply rate exceeding exhaust rate created re-circulations, turbulence, and fugitive emissions, while wasting energy. Smoke releases showing more effective ventilation here than in other aircraft painting facilities carries technical feasibility relevance. PMID:26698920

  6. Investigation of turbine ventilator performance after added wind cup for room exhaust air applications

    NASA Astrophysics Data System (ADS)

    Harun, D.; Zulfadhli; Akhyar, H.

    2018-05-01

    The turbine ventilator is a wind turbine with a vertical axis that has a combined function of the wind turbine and a suction fan. In this study, the turbine ventilator modified by adding a wind cup on the top (cap) turbine ventilator. The purpose of this experiment is to investigated the effect of the addition of wind cup on the turbine ventilator. Turbine ventilator used is type v30 and wind cup with diameter 77 mm. The experiment was conducted using a triangular pentagon model space chamber which was cut off to place the ventilator turbine ventilation cup with a volume of 0.983 m3 (equivalent to 1 mm3). The results of this study indicate that at an average wind speed of 1.8 m/s, the rotation of the turbine produced without a wind cup is 60.6 rpm while with the addition of a wind cup in the turbine ventilator is 69 rpm. The average increase of rotation turbine after added win cup is 8.4 rpm and the efficiency improvement of turbine ventilator is 1.7 %.

  7. PEM fuel cell monitoring system

    DOEpatents

    Meltser, M.A.; Grot, S.A.

    1998-06-09

    Method and apparatus are disclosed for monitoring the performance of H{sub 2}--O{sub 2} PEM fuel cells. Outputs from a cell/stack voltage monitor and a cathode exhaust gas H{sub 2} sensor are corrected for stack operating conditions, and then compared to predetermined levels of acceptability. If certain unacceptable conditions coexist, an operator is alerted and/or corrective measures are automatically undertaken. 2 figs.

  8. Modeling and Qualification of a Modified Emission Unit for Radioactive Air Emissions Stack Sampling Compliance.

    PubMed

    Barnett, J Matthew; Yu, Xiao-Ying; Recknagle, Kurtis P; Glissmeyer, John A

    2016-11-01

    A planned laboratory space and exhaust system modification to the Pacific Northwest National Laboratory Material Science and Technology Building indicated that a new evaluation of the mixing at the air sampling system location would be required for compliance to ANSI/HPS N13.1-2011. The modified exhaust system would add a third fan, thereby increasing the overall exhaust rate out the stack, thus voiding the previous mixing study. Prior to modifying the radioactive air emissions exhaust system, a three-dimensional computational fluid dynamics computer model was used to evaluate the mixing at the sampling system location. Modeling of the original three-fan system indicated that not all mixing criteria could be met. A second modeling effort was conducted with the addition of an air blender downstream of the confluence of the three fans, which then showed satisfactory mixing results. The final installation included an air blender, and the exhaust system underwent full-scale tests to verify velocity, cyclonic flow, gas, and particulate uniformity. The modeling results and those of the full-scale tests show agreement between each of the evaluated criteria. The use of a computational fluid dynamics code was an effective aid in the design process and allowed the sampling system to remain in its original location while still meeting the requirements for sampling at a well mixed location.

  9. Performance of Blowdown Turbine Driven by Exhaust Gas of Nine-Cylinder Radial Engine

    NASA Technical Reports Server (NTRS)

    Turner, L Richard; Desmon, Leland G

    1944-01-01

    An investigation was made of an exhaust-gas turbine having four separate nozzle boxes each covering a 90 degree arc of the nozzle diaphragm and each connected to a pair of adjacent cylinders of a nine-cylinder radial engine. This type of turbine has been called a "blowdown" turbine because it recovers the kinetic energy developed in the exhaust stacks during the blowdown period, that is the first part of the exhaust process when the piston of the reciprocating engine is nearly stationary. The purpose of the investigation was to determine whether the blow turbine could develop appreciable power without imposing any large loss in engine power arising from restriction of the engine exhaust by the turbine.

  10. Local ventilation solution for large, warm emission sources.

    PubMed

    Kulmala, Ilpo; Hynynen, Pasi; Welling, Irma; Säämänen, Arto

    2007-01-01

    In a foundry casting line, contaminants are released from a large area. Casting fumes include both volatile and particulate compounds. The volatile fraction contains hydrocarbons, whereas the particulate fraction mostly comprises a mixture of vaporized metal fumes. Casting fumes lower the air quality in foundries. The design of local ventilation for the casting area is a challenging task, because of the large casting area and convection plumes from warm moulds. A local ventilation solution for the mould casting area was designed and dimensioned with the aid of computational fluid dynamic (CFD) calculations. According to the calculations, the most efficient solution was a push-pull ventilation system. The prototype of the push-pull system was built and tested in actual operation at the foundry. The push flow was generated by a free plane jet that blew across the 10 m wide casting area towards an exhaust hood on the opposite side of the casting lines. The capture efficiency of the prototype was determined by the tracer gas method. The measured capture efficiencies with push jet varied between 40 and 80%, depending on the distance between the source and the exhaust. With the aid of the push flow, the average capture efficiency was increased from 40 (without jet) to 60%.

  11. Analysis of the systems of ventilation of residential houses of Ukraine and Estonia

    NASA Astrophysics Data System (ADS)

    Savchenko, Olena; Zhelykh, Vasyl; Voll, Hendrik

    2017-12-01

    The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.

  12. Preoperational test report, recirculation ventilation systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clifton, F.T.

    1997-11-11

    This represents a preoperational test report for Recirculation Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102 and supports the ability to exhaust air from each tank. Each system consists of a valved piping loop, a fan, condenser, and moisture separator; equipment is located inside each respective tank farm in its own hardened building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  13. Solid oxide fuel cell process and apparatus

    DOEpatents

    Cooper, Matthew Ellis [Morgantown, WV; Bayless, David J [Athens, OH; Trembly, Jason P [Durham, NC

    2011-11-15

    Conveying gas containing sulfur through a sulfur tolerant planar solid oxide fuel cell (PSOFC) stack for sulfur scrubbing, followed by conveying the gas through a non-sulfur tolerant PSOFC stack. The sulfur tolerant PSOFC stack utilizes anode materials, such as LSV, that selectively convert H.sub.2S present in the fuel stream to other non-poisoning sulfur compounds. The remaining balance of gases remaining in the completely or near H.sub.2S-free exhaust fuel stream is then used as the fuel for the conventional PSOFC stack that is downstream of the sulfur-tolerant PSOFC. A broad range of fuels such as gasified coal, natural gas and reformed hydrocarbons are used to produce electricity.

  14. 1. View from south to north of perimeter acquisition radar ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. View from south to north of perimeter acquisition radar power plant diesel engine exhaust and the small engine intake. On the right is the ventilating air intake/exhaust, distinguishable by its square shape, whereas the diesel columns are rectangular - Stanley R. Mickelsen Safeguard Complex, Perimeter Acquisition Radar Power Plant, In Limited Access Area, Southwest of PARB at end of Service Road B, Nekoma, Cavalier County, ND

  15. An Evaluation of an Aftermarket Local Exhaust Ventilation Device for Suppressing Respirable Dust and Respirable Crystalline Silica Dust from Powered Saws

    PubMed Central

    Garcia, Alberto; Jones, Erica; Echt, Alan S.; Hall, Ronald M.

    2015-01-01

    The objective of this study was to quantify the respirable dust and respirable silica exposures of roofing workers using an electric powered circular saw with an aftermarket local exhaust ventilation attachment to cut concrete roofing tiles. The study was conducted to determine whether the local exhaust ventilation attachment was able to control respirable dust and respirable silica exposure below occupational exposure limits. Time-integrated filter samples and direct reading respirable dust concentrations were evaluated. The local exhaust ventilation consisted of a shroud attached to the cutting plane of the saw; the shroud was then connected to a small electric axial fan, which is intended to collect dust at the point of generation. All sampling was conducted with the control in use. Roofers are defined as those individuals who solely lay tiles. Cutters/roofers are defined as those workers who operate the powered saw to cut tiles and also lay tiles. Respirable dust from this evaluation ranged from 0.13 to 6.59 milligrams per cubic meter (mg/m3) with a geometric mean of 0.38 mg/m3 for roofers and from 0.45 to 3.82 mg/m3 with a geometric mean of 1.84 mg/m3 for cutters/roofers. Cutters/roofers usually handle areas close to crevices, edges, or tips of the roof whereas roofers handle areas where complete tiles can be placed. The respirable dust exposures for all cutters/roofers indicated concentrations exceeding the Occupational Safety and Health Administration’s (OSHA) permissible exposure limit (PEL) for respirable dust containing silica; it was also exceeded for some of the roofers. The respirable silica concentrations ranged from 0.04 to 0.15 mg/m3 with an average of 0.09 mg/m3 for roofers, and from 0.13 to 1.21 mg/m3 with an average of 0.48 mg/m3 for cutters/roofers. As with respirable dust, the respirable silica exposures to cutters/roofers were higher than the exposures for roofers. PMID:25148513

  16. An evaluation of an aftermarket local exhaust ventilation device for suppressing respirable dust and respirable crystalline silica dust from powered saws.

    PubMed

    Garcia, Alberto; Jones, Erica; Echt, Alan S; Hall, Ronald M

    2014-01-01

    The objective of this study was to quantify the respirable dust and respirable silica exposures of roofing workers using an electric-powered circular saw with an aftermarket local exhaust ventilation attachment to cut concrete roofing tiles. The study was conducted to determine whether the local exhaust ventilation attachment was able to control respirable dust and respirable silica exposure below occupational exposure limits (OELs). Time-integrated filter samples and direct reading respirable dust concentrations were evaluated. The local exhaust ventilation consisted of a shroud attached to the cutting plane of the saw; the shroud was then connected to a small electric axial fan, which is intended to collect dust at the point of generation. All sampling was conducted with the control in use. Roofers are defined as those individuals who only lay tiles. Cutters/roofers are defined as those workers who operate the powered saw to cut tiles and also lay tiles. Respirable dust from this evaluation ranged from 0.13 to 6.59 milligrams per cubic meter (mg/m(3)) with a geometric mean of 0.38 mg/m(3) for roofers and from 0.45 to 3.82 mg/m(3) with a geometric mean of 1.84 mg/m(3) for cutters/roofers. Cutters/roofers usually handle areas close to crevices, edges, or tips of the roof whereas roofers handle areas where complete tiles can be placed. The respirable dust exposures for all cutters/roofers indicated concentrations exceeding the Occupational Safety and Health Administration's (OSHA) permissible exposure limit (PEL) for respirable dust containing silica; it was also exceeded for some of the roofers. The respirable silica concentrations ranged from 0.04 to 0.15 mg/m(3) with a geometric mean of 0.09 mg/m(3) for roofers, and from 0.13 to 1.21 mg/m(3) with a geometric mean of 0.48 mg/m(3) for cutters/roofers. As with respirable dust, the respirable silica exposures for cutters/roofers were higher than the exposures for roofers.

  17. Assessment of the Revised 3410 Building Filtered Exhaust Stack Sampling Probe Location

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Xiao-Ying; Recknagle, Kurtis P.; Glissmeyer, John A.

    2013-12-01

    In order to support the air emissions permit for the 3410 Building, Pacific Northwest National Laboratory performed a series of tests in the exhaust air discharge from the reconfigured 3410 Building Filtered Exhaust Stack. The objective was to determine whether the location of the air sampling probe for emissions monitoring meets the applicable regulatory criteria governing such effluent monitoring systems. In particular, the capability of the air sampling probe location to meet the acceptance criteria of ANSI/HPS N13.1-2011 , Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities was determined. The qualification criteriamore » for these types of stacks address 1) uniformity of air velocity, 2) sufficiently small flow angle with respect to the axis of the duct, 3) uniformity of tracer gas concentration, and 4) uniformity of tracer particle concentration. Testing was performed to conform to the quality requirements of NQA-1-2000. Fan configurations tested included all fan combinations of any two fans at a time. Most of the tests were conducted at the normal flow rate, while a small subset of tests was performed at a slightly higher flow rate achieved with the laboratory hood sashes fully open. The qualification criteria for an air monitoring probe location are taken from ANSI/HPS N13.1-2011 and are paraphrased as follows with key results summarized: 1. Angular Flow—The average air velocity angle must not deviate from the axis of the stack or duct by more than 20°. Our test results show that the mean angular flow angles at the center two-thirds of the ducts are smaller than 4.5% for all testing conditions. 2. Uniform Air Velocity—The acceptance criterion is that the COV of the air velocity must be ≤ 20% across the center two thirds of the area of the stack. Our results show that the COVs of the air velocity across the center two-thirds of the stack are smaller than 2.9% for all testing conditions. 3. Uniform Concentration of Tracer Gases—The uniformity of the concentration of potential contaminants is first tested using a tracer gas to represent gaseous effluents. The tracer is injected downstream of the fan outlets and at the junction downstream fan discharges meet. The acceptance criteria are that 1) the COV of the measured tracer gas concentration is ≤20% across the center two-thirds of the sampling plane and 2) at no point in the sampling plane does the concentration vary from the mean by >30%. Our test results show that 1) the COV of the measured tracer gas concentration is < 2.9% for all test conditions and 2) at no point in the sampling plane does the concentration vary from the mean by >6.5%. 4. Uniform Concentration of Tracer Particles—Tracer particles of 10-μm aerodynamic diameter are used for the second demonstration of concentration uniformity. The acceptance criterion is that the COV of particle concentration is ≤ 20% across the center two thirds of the sampling plane. Our test results indicate that the COV of particle concentration is <9.9% across the center two-thirds of the sampling plane among all testing conditions. Thus, the reconfigured 3410 Building Filtered Exhaust Stack was determined to meet the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Changes to the system configuration or operations outside the bounds described in this report (e.g., exhaust stack velocity changes, relocation of sampling probe, and addition of fans) may require re-testing or re-evaluation to determine compliance.« less

  18. Models for nearly every occasion: Part I - One box models.

    PubMed

    Hewett, Paul; Ganser, Gary H

    2017-01-01

    The standard "well mixed room," "one box" model cannot be used to predict occupational exposures whenever the scenario involves the use of local controls. New "constant emission" one box models are proposed that permit either local exhaust or local exhaust with filtered return, coupled with general room ventilation or the recirculation of a portion of the general room exhaust. New "two box" models are presented in Part II of this series. Both steady state and transient models were developed. The steady state equation for each model, including the standard one box steady state model, is augmented with an additional factor reflecting the fraction of time the substance was generated during each task. This addition allows the easy calculation of the average exposure for cyclic and irregular emission patterns, provided the starting and ending concentrations are zero or near zero, or the cumulative time across all tasks is long (e.g., several tasks to a full shift). The new models introduce additional variables, such as the efficiency of the local exhaust to immediately capture freshly generated contaminant and the filtration efficiency whenever filtered exhaust is returned to the workspace. Many of the model variables are knowable (e.g., room volume and ventilation rate). A structured procedure for calibrating a model to a work scenario is introduced that can be applied to both continuous and cyclic processes. The "calibration" procedure generates estimates of the generation rate and all of remaining unknown model variables.

  19. [Formaldehyde-reducing efficiency of a newly developed dissection-table-connected local ventilation system in the gross anatomy laboratory room].

    PubMed

    Shinoda, Koh; Oba, Jun

    2010-03-01

    In compliance with health and safety management guidelines against harmful formaldehyde (FA) levels in the gross anatomy laboratory, we newly developed a dissection-table-connected local ventilation system in 2006. The system was composed of (1) a simple plenum-chambered dissection table with low-cost filters, (2) a transparent vinyl flexible duct for easy mounting and removal, which connects the table and the exhaust pipe laid above the ceiling, and (3) an intake creating a downward-flow of air, which was installed on the ceiling just above each table. The dissection table was also designed as a separate-component system, of which the upper plate and marginal suction inlets can be taken apart for cleaning after dissection, and equipped with opening/closing side-windows for picking up materials dropped during dissection and a container underneath the table to receive exudate from the cadaver through a waste-fluid pipe. The local ventilation system dramatically reduced FA levels to 0.01-0.03 ppm in the gross anatomy laboratory room, resulting in no discomforting FA smell and irritating sensation while preserving the student's view of room and line of flow as well as solving the problems of high maintenance cost, sanitation issues inside the table, and working-inconvenience during dissection practice. Switching ventilation methods or power-modes, the current local ventilation system was demonstrated to be more than ten times efficient in FA reduction compared to the whole-room ventilation system and suggested that 11 m3/min/table in exhaust volume should decrease FA levels in both A- and B-measurements to less than 0.1 ppm in 1000 m3 space containing thirty-one 3.5%-FA-fixed cadavers.

  20. Generator module architecture for a large solid oxide fuel cell power plant

    DOEpatents

    Gillett, James E.; Zafred, Paolo R.; Riggle, Matthew W.; Litzinger, Kevin P.

    2013-06-11

    A solid oxide fuel cell module contains a plurality of integral bundle assemblies, the module containing a top portion with an inlet fuel plenum and a bottom portion receiving air inlet feed and containing a base support, the base supports dense, ceramic exhaust manifolds which are below and connect to air feed tubes located in a recuperator zone, the air feed tubes passing into the center of inverted, tubular, elongated, hollow electrically connected solid oxide fuel cells having an open end above a combustion zone into which the air feed tubes pass and a closed end near the inlet fuel plenum, where the fuel cells comprise a fuel cell stack bundle all surrounded within an outer module enclosure having top power leads to provide electrical output from the stack bundle, where the fuel cells operate in the fuel cell mode and where the base support and bottom ceramic air exhaust manifolds carry from 85% to all 100% of the weight of the stack, and each bundle assembly has its own control for vertical and horizontal thermal expansion control.

  1. 40 CFR Appendix I to Part 1068 - Emission-Related Components

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... system. 2. Fuel system. 3. Ignition system. 4. Exhaust gas recirculation systems. II. The following parts.... Crankcase ventilation valves. 3. Sensors. 4. Electronic control units. III. The following parts are...

  2. 40 CFR Appendix I to Part 1068 - Emission-Related Components

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... system. 2. Fuel system. 3. Ignition system. 4. Exhaust gas recirculation systems. II. The following parts.... Crankcase ventilation valves. 3. Sensors. 4. Electronic control units. III. The following parts are...

  3. Computational fluid dynamics study on the influence of an alternate ventilation configuration on the possible flow path of infectious cough aerosols in a mock airborne infection isolation room

    PubMed Central

    THATIPARTI, DEEPTHI SHARAN; GHIA, URMILA; MEAD, KENNETH R.

    2017-01-01

    When infectious epidemics occur, they can be perpetuated within health care settings, potentially resulting in severe health care workforce absenteeism, morbidity, mortality, and economic losses. The ventilation system configuration of an airborne infection isolation room is one factor that can play a role in protecting health care workers from infectious patient bioaerosols. Though commonly associated with airborne infectious diseases, the airborne infection isolation room design can also impact other transmission routes such as short-range airborne as well as fomite and contact transmission routes that are impacted by contagion concentration and recirculation. This article presents a computational fluid dynamics study on the influence of the ventilation configuration on the possible flow path of bioaerosol dispersal behavior in a mock airborne infection isolation room. At first, a mock airborne infection isolation room was modeled that has the room geometry and layout, ventilation parameters, and pressurization corresponding to that of a traditional ceiling-mounted ventilation arrangement observed in existing hospitals. An alternate ventilation configuration was then modeled to retain the linear supply diffuser in the original mock airborne infection isolation room but interchanging the square supply and exhaust locations to place the exhaust closer to the patient source and allow clean air from supply vents to flow in clean-to-dirty flow paths, originating in uncontaminated parts of the room prior to entering the contaminated patient’s air space. The modeled alternate airborne infection isolation room ventilation rate was 12 air changes per hour. Two human breathing models were used to simulate a source patient and a receiving health care worker. A patient cough cycle was introduced into the simulation, and the airborne infection dispersal was tracked in time using a multi-phase flow simulation approach. The results from the alternate configuration revealed that the cough aerosols were pulled by the exhaust vent without encountering the health care worker by 0.93 s after patient coughs and the particles were controlled as the aerosols’ flow path was uninterrupted by an air particle streamline from patient to the ceiling exhaust venting out cough aerosols. However, not all the aerosols were vented out of the room. The remaining cough aerosols entered the health care worker’s breathing zone by 0.98 s. This resulted in one of the critical stages in terms of the health care worker’s exposure to airborne virus and presented the opportunity for the health care worker to suffer adverse health effects from the inhalation of cough aerosols. Within 2 s, the cough aerosols reentered and recirculated within the patient and health care worker’s surroundings resulting in pockets of old contaminated air. By this time, coalescence losses decreased as the aerosol were no longer in very close proximity and their movement was primarily influenced by the airborne infection isolation room airflow patterns. In the patient and health care worker’s area away from the supply, the fresh air supply failed to reach this part of the room to quickly dilute the cough aerosol concentration. The exhaust was also found to have minimal effect upon cough aerosol removal, except for those areas with high exhaust velocities, very close to the exhaust grill. Within 5–20 s after a patient’s cough, the aerosols tended to break up to form smaller sized aerosols of less than one micron diameter. They remained airborne and entrained back into the supply air stream, spreading into the entire room. The suspended aerosols resulted in the floating time of more than 21 s in the room due to one cough cycle. The duration of airborne contagion in the room and its prolonged exposure to the health care worker is likely to happen due to successive coughing cycles. Hence, the evaluated alternate airborne infection isolation room is not effective in removing at least 38% particles exposed to health care worker within the first second of a patient’s cough. PMID:28736744

  4. [Contemporary solutions for better air quality at electric welders workplace].

    PubMed

    Markova, O L; Ivanova, E V

    2015-01-01

    The article deals with hygienic evaluation of electric welder's workplace, concerning chemical factor, with technical solutions on organization of supply-and-exhaust ventilation and methods to improve air quality in various welding tasks.

  5. 40 CFR 63.7765 - What definitions apply to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... through windows, vents, or other general building ventilation or exhaust systems are not considered to be... final shape, and harden the formed aggregate. This definition does not include a line for making green...

  6. The Development and Application of Spatiotemporal Metrics for the Characterization of Point Source FFCO2 Emissions and Dispersion

    NASA Astrophysics Data System (ADS)

    Roten, D.; Hogue, S.; Spell, P.; Marland, E.; Marland, G.

    2017-12-01

    There is an increasing role for high resolution, CO2 emissions inventories across multiple arenas. The breadth of the applicability of high-resolution data is apparent from their use in atmospheric CO2 modeling, their potential for validation of space-based atmospheric CO2 remote-sensing, and the development of climate change policy. This work focuses on increasing our understanding of the uncertainty in these inventories and the implications on their downstream use. The industrial point sources of emissions (power generating stations, cement manufacturing plants, paper mills, etc.) used in the creation of these inventories often have robust emissions characteristics, beyond just their geographic location. Physical parameters of the emission sources such as number of exhaust stacks, stack heights, stack diameters, exhaust temperatures, and exhaust velocities, as well as temporal variability and climatic influences can be important in characterizing emissions. Emissions from large point sources can behave much differently than emissions from areal sources such as automobiles. For many applications geographic location is not an adequate characterization of emissions. This work demonstrates the sensitivities of atmospheric models to the physical parameters of large point sources and provides a methodology for quantifying parameter impacts at multiple locations across the United States. The sensitivities highlight the importance of location and timing and help to highlight potential aspects that can guide efforts to reduce uncertainty in emissions inventories and increase the utility of the models.

  7. Generation rate of carbon monoxide from CO2 arc welding.

    PubMed

    Ojima, Jun

    2013-01-01

    CO poisoning has been a serious industrial hazard in Japanese workplaces. Although incomplete combustion is the major cause of CO generation, there is a risk of CO poisoning during some welding operations. The aim of the present study was to evaluate the generation rate of CO from CO2 arc welding under controlled laboratory conditions and estimate the ventilation requirements for the prevention of CO poisoning. Bead on plate welding was carried out with an automatic welding robot on a rolled steel base metal under several conditions. The concentration of emitted CO from the welding was measured by a real-time CO monitor in a well-ventilated laboratory that was free from ambient CO contamination. The generation rate of CO was obtained from the three measurements-the flow rate of the welding exhaust gas, CO concentration in the exhaust gas and the arcing time. Then the ventilation requirement to prevent CO poisoning was calculated. The generation rate of CO was found to be 386-883 ml/min with a solid wire and 331-1,293 ml/min with a flux cored wire respectively. It was found that the CO concentration in a room would be maintained theoretically below the OSHA PEL (50 ppm) providing the ventilation rate in the room was 6.6-25.9 m3/min. The actual ventilation requirement was then estimated to be 6.6-259 m3/min considering incomplete mixing. In order to prevent CO poisoning, some countermeasures against gaseous emission as well as welding fumes should be taken eagerly.

  8. On the Use of Windcatchers in Schools: Climate Change, Occupancy Patterns, and Adaptation Strategies

    PubMed Central

    Mumovic, D.

    2009-01-01

    Advanced naturally ventilated systems based on integration of basic natural ventilation strategies such as cross-ventilation and stack effect have been considered to be a key element of sustainable design. In this respect, there is a pressing need to explore the potential of such systems to achieve the recommended occupant comfort targets throughout their lifetime without relying on mechanical means. This study focuses on use of a windcatcher system in typical classrooms which are usually characterized by high and intermittent internal heat gains. The aims of this paper are 3-fold. First, to describe a series of field measurements that investigated the ventilation rates, indoor air quality, and thermal comfort in a newly constructed school located at an urban site in London. Secondly, to investigate the effect of changing climate and occupancy patterns on thermal comfort in selected classrooms, while taking into account adaptive potential of this specific ventilation strategy. Thirdly, to assess performance of the ventilation system using the newly introduced performance-based ventilation standards for school buildings. The results suggest that satisfactory occupant comfort levels could be achieved until the 2050s by a combination of advanced ventilation control settings and informed occupant behavior. PMID:27110216

  9. Using Waste Heat for External Processes (English/Chinese) (Fact Sheet) (in Chin3se; English)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Chinese translation of the Using Waste Heat for External Processes fact sheet. Provides suggestions on how to use waste heat in industrial applications. The temperature of exhaust gases from fuel-fired industrial processes depends mainly on the process temperature and the waste heat recovery method. Figure 1 shows the heat lost in exhaust gases at various exhaust gas temperatures and percentages of excess air. Energy from gases exhausted from higher temperature processes (primary processes) can be recovered and used for lower temperature processes (secondary processes). One example is to generate steam using waste heat boilers for the fluid heaters used inmore » petroleum crude processing. In addition, many companies install heat exchangers on the exhaust stacks of furnaces and ovens to produce hot water or to generate hot air for space heating.« less

  10. ADAPTING FTIR MEASUREMENT TECHNOLOGY TO HOMELAND SECURITY APPLICATIONS

    EPA Science Inventory

    Open-path Fourier transform infrared (OP-FTIR) sensors have numerous advantages for measuring chemical plumes over wide areas compared to point detection sensors. Extractive FTIR sensors have been used for industrial stack monitoring and are attractive for building ventilation sy...

  11. Cold Flow Testing of a Modified Subscale Model Exhaust System for a Space Based Laser

    DTIC Science & Technology

    2004-06-01

    Abstract The aim of this research was a continued study of gas-dynamic phenomena that occurred in a set of stacked nozzles as reported by Captains...join the vacuum and test sections. The goals of this research were two fold; first, modify the original scale-model of the stacked cylindrical...Defense Advanced Research Projects Agency (DARPA), in conjunction with the Airborne Laser Laboratory, have studied the use of an Airborne Laser (ABL

  12. Hanford Site radionuclide national emission standards for hazardous ari pollutants registered and and unregistered stack (powered exhaust) source assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, W.E.

    1995-12-01

    On February 3, 1993, US DOE Richland Operations Office received a Compliance Order and Information Request from the Director of the Air and Toxics Div. of US EPA, Region X. The compliance order requires the Richland Operations Office to evaluate all radionuclide emission points at the Hanford site to determine which are subject to the continuous emission measurement requirements in Title 40, Code of Federal Regulations (CFR), Part 61, Subpart H, and to continuously measure radionuclide emissions in accordance with 40 CFR 61.93. The Information Request required The provision of a written compliance plan to meet the requirements of themore » compliance order. A compliance plan was submitted to EPA, Region X, on April 30, 1993. It set as one of the milestones, the complete assessment of the Hanford Site 84 stacks registered with the Washington State Department of Health, by December 17, 1993. This milestone was accomplished. The compliance plan also called for reaching a Federal Facility Compliance Agreement; this was reached on February 7, 1994, between DOE Richland Operations and EPA, Region X. The milestone to assess the unregistered stacks (powered exhaust) by August 31, 1994, was met. This update presents assessments for 72 registered and 22 unregistered stacks with potential emissions > 0.1 mrem/yr.« less

  13. Examination of redirected continuous miner scrubber discharge configurations for exhaust face ventilation systems

    PubMed Central

    Organiscak, J.A.; Beck, T.W.

    2015-01-01

    The U.S. National Institute for Occupational Safety and Health (NIOSH) Office of Mine Safety and Health Research (OMSHR) has recently studied several redirected scrubber discharge configurations in its full-scale continuous miner gallery for both dust and gas control when using an exhaust face ventilation system. Dust and gas measurements around the continuous mining machine in the laboratory showed that the conventional scrubber discharge directed outby the face with a 12.2-m (40-ft) exhaust curtain setback appeared to be one of the better configurations for controlling dust and gas. Redirecting all the air toward the face equally up both sides of the machine increased the dust and gas concentrations around the machine. When all of the air was redirected toward the face on the off-curtain side of the machine, gas accumulations tended to be reduced at the face, at the expense of increased dust levels in the return and on the curtain side of the mining machine. A 6.1-m (20-ft) exhaust curtain setback without the scrubber operating resulted in the lowest dust levels around the continuous mining machine, but this configuration resulted in some of the highest levels of dust in the return and gas on the off-curtain side of the mining face. Two field studies showed some similarities to the laboratory findings, with elevated dust levels at the rear corners of the continuous miner when all of the scrubber exhaust was redirected toward the face either up the off-tubing side or equally up both sides of the mining machine. PMID:26251566

  14. A case study of methane gas migration through sealed mine GOB into active mine workings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia, F.; McCall, F.E.; Trevits, M.A.

    1995-12-31

    The U.S. Bureau of Mines investigated the influence of atmospheric pressure changes on methane gas migration through mine seals at a mine site located in the Pittsburgh Coalbed. The mine gained access to a coal reserve through part of an abandoned mine and constructed nine seals to isolate the extensive old workings from the active mine area. Underground problems were experienced when atmospheric pressure fell, causing methane gas to migrate around the seals and into the active workings. During mining operations, methane gas levels exceeded legal limits and coal production was halted until the ventilation system could be improved. Whenmore » mining resumed with increased air flow, methane gas concentrations occasionally exceeded the legal limits and production had to be halted until the methane level fell within the mandated limit. To assist the ventilation system, a pressure relief borehole located in the abandoned workings near the mine seals was proposed. Preliminary estimates by a gob gas simulator (computer model) suggested that a 0.76 m (2.5 ft) diameter pressure relief borehole with an exhaust fan would be necessary to remove enough methane from the abandoned area so that the ventilation system could dilute the gas in the active workings. However, by monitoring methane gas emissions and seal pressure, during periods of low atmospheric pressure, the amount of methane gas that migrated into the active mine workings was calculated. Researchers then determined that a relief borehole, 20.3 cm (8-in) with an exhaust fan could remove at least twice the maximum measured volume of migrating methane gas. Because gas concentrations in the abandoned workings could potentially reach explosive limits, it was proposed that the mine eliminate the exhaust fan. Installation of the recommended borehole and enlarging two other ventilation boreholes located In the abandoned area reduced methane gas leakage through the seals by at least 63%.« less

  15. Gravimetric and analytical evaluation of welding fume in an automobile part manufacturing factory.

    PubMed

    Mansouri, N; Atbi, F; Moharamnezhad, N; Rahbaran, D A; Alahiari, M

    2008-12-28

    Welding is one of the most exercised industrial processes which welders are exposed to chemical and physical Hazardous agents. This study was conducted to evaluate occupational and environmental exposures to aerosols generated by welding processes in a factory. A total of 28 samples of aerosols were collected at 4 different locations including indoor, outdoor, source of welding and the stacks using a high volume pump with a volumetric flow rate of 112 lit/min calibrated with a dry gas meter. The samples were collected on round 110 mm fiber glass filters, measured gravimetrically, extracted using nitric acid and analyzed with atomic absorption spectroscopy method for heavy metals including Fe, Mn, Ni, Cr3+, Cr+6, Co, and Zn. Gravimetric measuring has shown the mean values of indoor air: 1.33 mg/m3, breathing zone of the welders using coated electrodes and CO2: 7.25 mg/m3 and 6.45 mg/m3 respectively and in ventilation exhausts: 95.07 mg/m3. The mean values of Fe, Mn, and Ni were 0.8, 0.041, and 0.00 mg/m3 in indoor air, 2.7, 0.18, and 0.15 mg/m3 in breathing zone of welders used coated electrodes, and 1.75, 0.08, and 0.22 mg/m3 in breathing zone of welders used CO2 welding respectively. The concentrations of Cr3+, Cr+6, Co, and Zn were too low to be detected. The welders were exposed to high concentration of metallic fumes, which raise the risk of pulmonary dysfunction and other health disorders. Using suitable respiratory masks and Appling the effective local ventilation system may improve the working condition.

  16. Project W-320, 241-C-106 sluicing HVAC calculations, Volume 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bailey, J.W.

    1998-08-07

    This supporting document has been prepared to make the FDNW calculations for Project W-320, readily retrievable. The report contains the following calculations: Exhaust airflow sizing for Tank 241-C-106; Equipment sizing and selection recirculation fan; Sizing high efficiency mist eliminator; Sizing electric heating coil; Equipment sizing and selection of recirculation condenser; Chiller skid system sizing and selection; High efficiency metal filter shielding input and flushing frequency; and Exhaust skid stack sizing and fan sizing.

  17. Controlling Indoor Air Pollution from Moxibustion

    PubMed Central

    Lu, Chung-Yen; Kang, Sy-Yuan; Liu, Shu-Hui; Mai, Cheng-Wei; Tseng, Chao-Heng

    2016-01-01

    Indoor air quality (IAQ) control of hospitals plays a critical role in protecting both hospital staffs and patients, particularly those who are highly susceptible to the adverse effects of indoor noxious hazards. However, moxibustion in outpatient departments (OPDs) of traditional Chinese medicine (TCM) may be a source of indoor air pollution in hospitals. Some studies have investigated indoor air pollution during moxibustion in Chinese medicine clinics (CMCs) and moxibustion rooms, demonstrating elevated air pollutants that pose a threat to the health of medical staff and patients. Our study investigated the indoor air pollutants of indoor carbon dioxide (CO2), carbon monoxide (CO), formaldehyde (HCHO), total volatile organic compounds (TVOCs), airborne particulate matter with a diameter of ≤10 µm (PM10) and ≤2.5 µm (PM2.5) during moxibustion in an acupuncture and moxibustion room of the OPD in a hospital in Taipei. To evaluate the different control strategies for indoor air pollution from moxibution, a comparison of air pollutants during moxibution among the methods of using alternative old moxa wools, local exhaust ventilation and an air cleaner was conducted. In this study, burning alternative old moxa wools for moxibustion obviously reduced all gaseous pollutants except for aerosols comparing burning fresh moxa wools. Using local exhaust ventilation reduced most of the aerosols after burning moxa. We also found that using an air cleaner was inefficient for controlling indoor air pollutants, particularly gaseous pollutants. Therefore, combining replacing alternative old moxa wools and local exhaust ventilation could be a suitable design for controlling indoor air pollution during moxibustion therapy. PMID:27331817

  18. Controlling Indoor Air Pollution from Moxibustion.

    PubMed

    Lu, Chung-Yen; Kang, Sy-Yuan; Liu, Shu-Hui; Mai, Cheng-Wei; Tseng, Chao-Heng

    2016-06-20

    Indoor air quality (IAQ) control of hospitals plays a critical role in protecting both hospital staffs and patients, particularly those who are highly susceptible to the adverse effects of indoor noxious hazards. However, moxibustion in outpatient departments (OPDs) of traditional Chinese medicine (TCM) may be a source of indoor air pollution in hospitals. Some studies have investigated indoor air pollution during moxibustion in Chinese medicine clinics (CMCs) and moxibustion rooms, demonstrating elevated air pollutants that pose a threat to the health of medical staff and patients. Our study investigated the indoor air pollutants of indoor carbon dioxide (CO₂), carbon monoxide (CO), formaldehyde (HCHO), total volatile organic compounds (TVOCs), airborne particulate matter with a diameter of ≤10 µm (PM10) and ≤2.5 µm (PM2.5) during moxibustion in an acupuncture and moxibustion room of the OPD in a hospital in Taipei. To evaluate the different control strategies for indoor air pollution from moxibution, a comparison of air pollutants during moxibution among the methods of using alternative old moxa wools, local exhaust ventilation and an air cleaner was conducted. In this study, burning alternative old moxa wools for moxibustion obviously reduced all gaseous pollutants except for aerosols comparing burning fresh moxa wools. Using local exhaust ventilation reduced most of the aerosols after burning moxa. We also found that using an air cleaner was inefficient for controlling indoor air pollutants, particularly gaseous pollutants. Therefore, combining replacing alternative old moxa wools and local exhaust ventilation could be a suitable design for controlling indoor air pollution during moxibustion therapy.

  19. Ventilation and infiltration in high-rise apartment buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diamond, R.C.; Feustel, H.E.; Dickerhoff, D.J.

    1996-03-01

    Air flow, air leakage measurements and numerical simulations were made on a 13-story apartment building to characterize the ventilation rates for the individual apartments. Parametric simulations were performed for specific conditions, e.g., height, orientation, outside temperature and wind speed. Our analysis of the air flow simulations suggest that the ventilation to the individual units varies considerably. With the mechanical ventilation system disabled and no wind, units at the lower level of the building have adequate ventilation only on days with high temperature differences, while units on higher floors have no ventilation at all. Units facing the windward side will bemore » over-ventilated when the building experiences wind directions between west and north. At the same time, leeward apartments did not experience any fresh air-because, in these cases, air flows enter the apartments from the corridor and exit through the exhaust shafts and the cracks in the facade. Even with the mechanical ventilation system operating, we found wide variation in the air flows to the individual apartments. In addition to the specific case presented here, these findings have more general implications for energy retrofits and health and comfort of occupants in high-rise apartment buildings.« less

  20. 40 CFR 63.7851 - Who implements and enforces this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... defined in § 63.90, except for approval of an alternative method for the oil content of the sinter plant feedstock or volatile organic compound measurements for the sinter plant windbox exhaust stream stack as...

  1. 40 CFR 63.7851 - Who implements and enforces this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... defined in § 63.90, except for approval of an alternative method for the oil content of the sinter plant feedstock or volatile organic compound measurements for the sinter plant windbox exhaust stream stack as...

  2. 40 CFR 63.7851 - Who implements and enforces this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... defined in § 63.90, except for approval of an alternative method for the oil content of the sinter plant feedstock or volatile organic compound measurements for the sinter plant windbox exhaust stream stack as...

  3. 40 CFR 63.7851 - Who implements and enforces this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... defined in § 63.90, except for approval of an alternative method for the oil content of the sinter plant feedstock or volatile organic compound measurements for the sinter plant windbox exhaust stream stack as...

  4. Fuel cell with internal flow control

    DOEpatents

    Haltiner, Jr., Karl J.; Venkiteswaran, Arun [Karnataka, IN

    2012-06-12

    A fuel cell stack is provided with a plurality of fuel cell cassettes where each fuel cell cassette has a fuel cell with an anode and cathode. The fuel cell stack includes an anode supply chimney for supplying fuel to the anode of each fuel cell cassette, an anode return chimney for removing anode exhaust from the anode of each fuel cell cassette, a cathode supply chimney for supplying oxidant to the cathode of each fuel cell cassette, and a cathode return chimney for removing cathode exhaust from the cathode of each fuel cell cassette. A first fuel cell cassette includes a flow control member disposed between the anode supply chimney and the anode return chimney or between the cathode supply chimney and the cathode return chimney such that the flow control member provides a flow restriction different from at least one other fuel cell cassettes.

  5. A Study on The Development of Local Exhaust Ventilation System (LEV’s) for Installation of Laser Cutting Machine

    NASA Astrophysics Data System (ADS)

    Harun, S. I.; Idris, S. R. A.; Tamar Jaya, N.

    2017-09-01

    Local exhaust ventilation (LEV) is an engineering system frequently used in the workplace to protect operators from hazardous substances. The objective of this project is design and fabricate the ventilation system as installation for chamber room of laser cutting machine and to stimulate the air flow inside chamber room of laser cutting machine with the ventilation system that designed. LEV’s fabricated with rated voltage D.C 10.8V and 1.5 ampere. Its capacity 600 ml, continuously use limit approximately 12-15 minute, overall length LEV’s fabricated is 966 mm with net weight 0.88 kg and maximum airflow is 1.3 meter cubic per minute. Stimulate the air flow inside chamber room of laser cutting machine with the ventilation system that designed and fabricated overall result get 2 main gas vapor which air and carbon dioxide. For air gas which experimented by using anemometer, general duct velocity that produce is same with other gas produce, carbon dioxide which 5 m/s until 10 m/s. Overall result for 5 m/s and 10 m/s as minimum and maximum duct velocity produce for both air and carbon dioxide. The air gas flow velocity that captured by LEV’s fabricated, 3.998 m/s average velocity captured from 5 m/s duct velocity which it efficiency of 79.960% and 7.667 m/s average velocity captured from 10 m/s duct velocity with efficiency of 76.665%. For carbon dioxide gas flow velocity that captured by LEV’s fabricated, 3.674 m/s average velocity captured from 5 m/s duct velocity which it efficiency of 73.480% and 8.255 m/s average velocity captured from 10 m/s duct velocity with efficiency of 82.545%.

  6. [Poisoning by exhaust gas of the imperfect combustion of natural gas: 22 cases study].

    PubMed

    Dong, Li-Min; Zhao, Hai; Zhang, Ming-Chang; He, Meng

    2014-10-01

    To analyze the case characteristics of poisoning by exhaust gas of the imperfect combustion of natural gas and provide references for forensic identification and prevention of such accidents. Twenty-two cases of poisoning by exhaust gas of the imperfect combustion of natural gas in Minhang District during 2004 to 2013 were collected. Some aspects such as general conditions of deaths, incidence time, weather, field investigation, and autopsy were retrospectively analyzed. In the 22 cases, there were 15 males and 16 females. The age range was between 2 and 82 years old. The major occurring time was in January or February (8 cases in each) and the cases almost occurred in small area room (21 cases). There was wide crack next to the exhaust port when the gas water heater was been used in all cases. There are more prone to occurrence of exhaust gas poisoning of imperfect combustion of natural gas in small area room with a ventilation window near the exhaust port of gas water heated. It shows that the scene of combustion exhaust gas poisoning should be more concerned in the cold season.

  7. 40 CFR 61.53 - Stack sampling.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... operator employing mercury chlor-alkali cell(s) shall test emissions from hydrogen streams according to... the Administrator, for a minimum of 2 years. (b) Mercury chlor-alkali plant—hydrogen and end-box.... (c) Mercury chlor-alkali plants—cell room ventilation system. (1) Stationary sources using mercury...

  8. 40 CFR 61.53 - Stack sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operator employing mercury chlor-alkali cell(s) shall test emissions from hydrogen streams according to... the Administrator, for a minimum of 2 years. (b) Mercury chlor-alkali plant—hydrogen and end-box.... (c) Mercury chlor-alkali plants—cell room ventilation system. (1) Stationary sources using mercury...

  9. 40 CFR 61.53 - Stack sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... operator employing mercury chlor-alkali cell(s) shall test emissions from hydrogen streams according to... the Administrator, for a minimum of 2 years. (b) Mercury chlor-alkali plant—hydrogen and end-box.... (c) Mercury chlor-alkali plants—cell room ventilation system. (1) Stationary sources using mercury...

  10. Exhaust-Stack Nozzle Area and Shape for Individual Cylinder Exhaust-Gas Jet-Propulsion System

    DTIC Science & Technology

    1943-01-01

    ty and con- siderable loss in the availabfity of the energy occurs because of acoustic shock and because the kinetic energy is trans- formed into heat ...plate in the air-intake duct. A tank was installed between the engine and the oriiice plata to damp out pulsations . The fuel flow was measured by a...with a length of flexible tubing. A tap for measuring static pres- sure was locxded in the tank. Tank pressures were main- tained by operation of an

  11. Laboratory Evaluation of Energy Recovery Ventilators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kosar, D.

    Over the years, building scientists have characterized the relationship between building airtightness, exhaust-only appliances airflows, and building depressurization. Now, as the use of deep retrofit measures and new construction practices is growing to realize lower infiltration levels in increasingly tighter envelopes, performance issues can arise with the operation of exhaust-only appliances in a depressurized home. As the depressurization levels climb in tighter homes, many of these exhaust-only appliances see their rated airflows reduced and other related performance issues arise as a result. If sufficiently depressurized, atmospherically vented combustion appliances that may be present in the home can backdraft as well.more » Furthermore, when exhaust-only appliances operate and the tight home becomes depressurized, water vapor intrusion from outdoors can raise additional issues of mold in the building envelope in more humid climates.« less

  12. PAINT SPRAY BOOTH MODIFICATIONS FOR RECIRCULATION VENTILATION

    EPA Science Inventory

    The control of emissions from spray painting operations has historically been cost prohibitive, due to the high exhaust flow rates coupled with low volatile organic compound (VOC) and hazardous air pollutant (HAP) Concentrations. Past studies, conducted by the U.S. EPA and U.S. ...

  13. NPDES Permit for Cheyenne Mountain Air Force Station in Colorado

    EPA Pesticide Factsheets

    Under NPDES permit CO-0034762, the Cheyenne Mountain Air Force Station is authorized to discharge from the interior storm drainage system and air exhaust stacks at the Cheyenne Mountain Complex in El Paso County, Colorado, to tributaries Fountain Creek.

  14. 15. SITE BUILDING 004 ELECTRIC POWER STATION VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. SITE BUILDING 004 - ELECTRIC POWER STATION - VIEW IS LOOKING SOUTH 55° EAST AT FIVE DIESEL ENGINE/ GENERATOR SILENCER SYSTEM EXHAUST STACKS. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA

  15. Flow-field characteristics of high-temperature annular buoyant jets and their development laws influenced by ventilation system.

    PubMed

    Wang, Yi; Huang, Yanqiu; Liu, Jiaping; Wang, Hai; Liu, Qiuhan

    2013-01-01

    The flow-field characteristics of high-temperature annular buoyant jets as well as the development laws influenced by ventilation system were studied using numerical methods to eliminate the pollutants effectively in this paper. The development laws of high-temperature annular buoyant jets were analyzed and compared with previous studies, including radial velocity distribution, axial velocity and temperature decay, reattachment position, cross-section diameter, volumetric flow rate, and velocity field characteristics with different pressures at the exhaust hood inlet. The results showed that when the ratio of outer diameter to inner diameter of the annulus was smaller than 5/2, the flow-field characteristics had significant difference compared to circular buoyant jets with the same outer diameter. For similar diameter ratios, reattachment in this paper occurred further downstream in contrast to previous study. Besides, the development laws of volumetric flow rate and cross-section diameter were given with different initial parameters. In addition, through analyzing air distribution characteristics under the coupling effect of high-temperature annular buoyant jets and ventilation system, it could be found that the position where maximum axial velocity occurred was changing gradually when the pressure at the exhaust hood inlet changed from 0 Pa to -5 Pa.

  16. Flow-Field Characteristics of High-Temperature Annular Buoyant Jets and Their Development Laws Influenced by Ventilation System

    PubMed Central

    Liu, Jiaping; Wang, Hai; Liu, Qiuhan

    2013-01-01

    The flow-field characteristics of high-temperature annular buoyant jets as well as the development laws influenced by ventilation system were studied using numerical methods to eliminate the pollutants effectively in this paper. The development laws of high-temperature annular buoyant jets were analyzed and compared with previous studies, including radial velocity distribution, axial velocity and temperature decay, reattachment position, cross-section diameter, volumetric flow rate, and velocity field characteristics with different pressures at the exhaust hood inlet. The results showed that when the ratio of outer diameter to inner diameter of the annulus was smaller than 5/2, the flow-field characteristics had significant difference compared to circular buoyant jets with the same outer diameter. For similar diameter ratios, reattachment in this paper occurred further downstream in contrast to previous study. Besides, the development laws of volumetric flow rate and cross-section diameter were given with different initial parameters. In addition, through analyzing air distribution characteristics under the coupling effect of high-temperature annular buoyant jets and ventilation system, it could be found that the position where maximum axial velocity occurred was changing gradually when the pressure at the exhaust hood inlet changed from 0 Pa to −5 Pa. PMID:24000278

  17. A Passive Cavity Concept for Improving the Off-Design Performance of Fixed-Geometry Exhaust Nozzles

    NASA Technical Reports Server (NTRS)

    Asbury, Scott C.; Gunther, Christopher L.; Hunter, Craig A.

    1996-01-01

    An investigation was conducted in the model preparation area of the Langley 16-Foot Transonic Tunnel to study a passive cavity concept for improving the off-design performance of fixed-geometry exhaust nozzles. Passive cavity ventilation (through a porous surface) was applied to divergent flap surfaces and tested at static conditions in a sub-scale, nonaxisymmetric, convergent-divergent nozzle. As part of a comprehensive investigation, force, moment and pressure measurements were taken and focusing schlieren flow visualization was obtained for a baseline configuration and D passive cavity configurations. All tests were conducted with no external flow and high-pressure air was used to simulate jet-exhaust flow at nozzle pressure ratios from 1.25 to approximately 9.50. Results indicate that baseline nozzle performance was dominated by unstable shock-induced boundary-layer separation at off-design conditions, which came about through the natural tendency of overexpanded exhaust flow to satisfy conservation requirements by detaching from the nozzle divergent flaps. Passive cavity ventilation added the ability to control off-design separation in the nozzle by either alleviating separation or encouraging stable separation of the exhaust flow. Separation alleviation offers potential for installed nozzle performance benefits by reducing drag at forward flight speeds, even though it may reduce off-design static thrust efficiency as much as 3.2 percent. Encouraging stable separation of the exhaust flow offers significant performance improvements at static, low NPR and low Mach number flight conditions by improving off-design static thrust efficiency as much as 2.8 percent. By designing a fixed-geometry nozzle with fully porous divergent flaps, where both cavity location and percent open porosity of the flaps could be varied, passive flow control would make it possible to improve off-design nozzle performance across a wide operating range. In addition, the ability to encourage separation on one flap while alleviating it on the other makes it possible to generate thrust vectoring in the nozzle through passive flow control.

  18. Process test plan, phase II: waste retrieval sluicing system emissions collection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    POWERS, R.L.

    1999-06-01

    This Process Test Plan is prepared to continue from HNF-3733 which was Phase I of the test. Supplemental operational controls and sampling requirements are defined to safely obtain gas samples from the 296-C-006 ventilation system stack during active operation of the sluicing equipment.

  19. 40 CFR 89.109 - Maintenance instructions and minimum allowable maintenance intervals.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... change, oil filter change, fuel filter change, air filter change, cooling system maintenance, adjustment... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION...) Exhaust gas recirculation system-related filters and coolers. (ii) Positive crankcase ventilation valve...

  20. 40 CFR 89.109 - Maintenance instructions and minimum allowable maintenance intervals.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... change, oil filter change, fuel filter change, air filter change, cooling system maintenance, adjustment... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION...) Exhaust gas recirculation system-related filters and coolers. (ii) Positive crankcase ventilation valve...

  1. Clean the Air and Breathe Easier.

    ERIC Educational Resources Information Center

    Guevin, John

    1997-01-01

    Failure to prevent indoor air quality problems or act promptly can result in increased chances for long- or short-term health problems for staff and students, reduced productivity, faster plant deterioration, and strained school-community relations. Basic pollution control measures include source management, local exhausts, ventilation, exposure…

  2. 40 CFR 60.747 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels... recent performance test that demonstrated compliance. (ii) For carbon adsorption systems with individual...

  3. 40 CFR 60.747 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels... recent performance test that demonstrated compliance. (ii) For carbon adsorption systems with individual...

  4. 40 CFR 60.747 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels... recent performance test that demonstrated compliance. (ii) For carbon adsorption systems with individual...

  5. 40 CFR 60.747 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels... recent performance test that demonstrated compliance. (ii) For carbon adsorption systems with individual...

  6. Solid oxide fuel cell generator with removable modular fuel cell stack configurations

    DOEpatents

    Gillett, J.E.; Dederer, J.T.; Zafred, P.R.; Collie, J.C.

    1998-04-21

    A high temperature solid oxide fuel cell generator produces electrical power from oxidation of hydrocarbon fuel gases such as natural gas, or conditioned fuel gases, such as carbon monoxide or hydrogen, with oxidant gases, such as air or oxygen. This electrochemical reaction occurs in a plurality of electrically connected solid oxide fuel cells bundled and arrayed in a unitary modular fuel cell stack disposed in a compartment in the generator container. The use of a unitary modular fuel cell stack in a generator is similar in concept to that of a removable battery. The fuel cell stack is provided in a pre-assembled self-supporting configuration where the fuel cells are mounted to a common structural base having surrounding side walls defining a chamber. Associated generator equipment may also be mounted to the fuel cell stack configuration to be integral therewith, such as a fuel and oxidant supply and distribution systems, fuel reformation systems, fuel cell support systems, combustion, exhaust and spent fuel recirculation systems, and the like. The pre-assembled self-supporting fuel cell stack arrangement allows for easier assembly, installation, maintenance, better structural support and longer life of the fuel cells contained in the fuel cell stack. 8 figs.

  7. Solid oxide fuel cell generator with removable modular fuel cell stack configurations

    DOEpatents

    Gillett, James E.; Dederer, Jeffrey T.; Zafred, Paolo R.; Collie, Jeffrey C.

    1998-01-01

    A high temperature solid oxide fuel cell generator produces electrical power from oxidation of hydrocarbon fuel gases such as natural gas, or conditioned fuel gases, such as carbon monoxide or hydrogen, with oxidant gases, such as air or oxygen. This electrochemical reaction occurs in a plurality of electrically connected solid oxide fuel cells bundled and arrayed in a unitary modular fuel cell stack disposed in a compartment in the generator container. The use of a unitary modular fuel cell stack in a generator is similar in concept to that of a removable battery. The fuel cell stack is provided in a pre-assembled self-supporting configuration where the fuel cells are mounted to a common structural base having surrounding side walls defining a chamber. Associated generator equipment may also be mounted to the fuel cell stack configuration to be integral therewith, such as a fuel and oxidant supply and distribution systems, fuel reformation systems, fuel cell support systems, combustion, exhaust and spent fuel recirculation systems, and the like. The pre-assembled self-supporting fuel cell stack arrangement allows for easier assembly, installation, maintenance, better structural support and longer life of the fuel cells contained in the fuel cell stack.

  8. Acceptance test report for portable exhauster POR-008/Skid F

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kriskovich, J.R.

    1998-07-24

    Portable Exhauster POR-008 was procured via HNF-0490, Specification for a Portable Exhausted System for Waste Tank Ventilation. Prior to taking ownership, acceptance testing was performed at the vendors. However at the conclusion of testing a number of issues remained that required resolution before the exhausters could be used by Project W-320. The purpose of acceptance testing documented by this report was to demonstrate compliance of the exhausters with the performance criteria established within HNF-O49O, Rev. 1 following a repair and upgrade effort at Hanford. In addition, data obtained during this testing is required for the resolution of outstanding Non-conformance Reportsmore » (NCR), and finally, to demonstrate the functionality of the associated software for the pressure control and high vacuum exhauster operating modes provided for by W-320. Additional testing not required by the ATP was also performed to assist in the disposition and close out of receiving inspection report and for application design information (system curve). Results of this testing are also captured within this document.« less

  9. Evaluation of carcinogenic hazard of diesel engine exhaust needs to consider revolutionary changes in diesel technology.

    PubMed

    McClellan, Roger O; Hesterberg, Thomas W; Wall, John C

    2012-07-01

    Diesel engines, a special type of internal combustion engine, use heat of compression, rather than electric spark, to ignite hydrocarbon fuels injected into the combustion chamber. Diesel engines have high thermal efficiency and thus, high fuel efficiency. They are widely used in commerce prompting continuous improvement in diesel engines and fuels. Concern for health effects from exposure to diesel exhaust arose in the mid-1900s and stimulated development of emissions regulations and research to improve the technology and characterize potential health hazards. This included epidemiological, controlled human exposure, laboratory animal and mechanistic studies to evaluate potential hazards of whole diesel exhaust. The International Agency for Research on Cancer (1989) classified whole diesel exhaust as - "probably carcinogenic to humans". This classification stimulated even more stringent regulations for particulate matter that required further technological developments. These included improved engine control, improved fuel injection system, enhanced exhaust cooling, use of ultra low sulfur fuel, wall-flow high-efficiency exhaust particulate filters, exhaust catalysts, and crankcase ventilation filtration. The composition of New Technology Diesel Exhaust (NTDE) is qualitatively different and the concentrations of particulate constituents are more than 90% lower than for Traditional Diesel Exhaust (TDE). We recommend that future reviews of carcinogenic hazards of diesel exhaust evaluate NTDE separately from TDE. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. 40 CFR 60.144a - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... replaced with the following instructions for recording observations and reducing data: (i) Section 2.4... follows: (1) For devices that monitor and record the exhaust ventilation rate, compare velocity readings recorded by the monitoring device against the velocity readings obtained by Method 2. Take Method 2...

  11. 40 CFR 60.144a - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... replaced with the following instructions for recording observations and reducing data: (i) Section 2.4... follows: (1) For devices that monitor and record the exhaust ventilation rate, compare velocity readings recorded by the monitoring device against the velocity readings obtained by Method 2. Take Method 2...

  12. 46 CFR 97.80-1 - Special operating conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... exhausts of power-operated industrial trucks shall have adequate ventilation. The senior deck officer shall... which persons are working, by persons acquainted with the test equipment and procedure. The carbon monoxide concentration in the holds and intermediate decks where persons are working shall be maintained at...

  13. 40 CFR 63.843 - Emission limits for existing sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) The emission capture system shall be installed and operated to meet the generally accepted engineering standards for minimum exhaust rates as published by the American Conference of Governmental Industrial Hygienists in Chapters 3 and 5 of “Industrial Ventilation: A Handbook of Recommended Practice” (incorporated...

  14. 40 CFR 63.843 - Emission limits for existing sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) The emission capture system shall be installed and operated to meet the generally accepted engineering standards for minimum exhaust rates as published by the American Conference of Governmental Industrial Hygienists in Chapters 3 and 5 of “Industrial Ventilation: A Handbook of Recommended Practice” (incorporated...

  15. 40 CFR 63.843 - Emission limits for existing sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) The emission capture system shall be installed and operated to meet the generally accepted engineering standards for minimum exhaust rates as published by the American Conference of Governmental Industrial Hygienists in Chapters 3 and 5 of “Industrial Ventilation: A Handbook of Recommended Practice” (incorporated...

  16. 40 CFR 63.843 - Emission limits for existing sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) The emission capture system shall be installed and operated to meet the generally accepted engineering standards for minimum exhaust rates as published by the American Conference of Governmental Industrial Hygienists in Chapters 3 and 5 of “Industrial Ventilation: A Handbook of Recommended Practice” (incorporated...

  17. 40 CFR 63.843 - Emission limits for existing sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) The emission capture system shall be installed and operated to meet the generally accepted engineering standards for minimum exhaust rates as published by the American Conference of Governmental Industrial Hygienists in Chapters 3 and 5 of “Industrial Ventilation: A Handbook of Recommended Practice” (incorporated...

  18. 40 CFR 60.4880 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... section are met. (A) The zero (low-level), mid-level (if applicable), or high-level calibration drift... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  19. 40 CFR 60.4880 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... section are met. (A) The zero (low-level), mid-level (if applicable), or high-level calibration drift... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  20. 40 CFR 60.4880 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... section are met. (A) The zero (low-level), mid-level (if applicable), or high-level calibration drift... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  1. Method of removing oxides of sulfur and oxides of nitrogen from exhaust gases

    DOEpatents

    Walker, Richard J.

    1986-01-01

    A continuous method is presented for removing both oxides of sulfur and oxides of nitrogen from combustion or exhaust gases with the regeneration of the absorbent. Exhaust gas is cleaned of particulates and HCl by a water scrub prior to contact with a liquid absorbent that includes an aqueous solution of bisulfite and sulfite ions along with a metal chelate, such as, an iron or zinc aminopolycarboxylic acid. Following contact with the combustion gases the spent absorbent is subjected to electrodialysis to transfer bisulfite ions into a sulfuric acid solution while splitting water with hydroxide and hydrogen ion migration to equalize electrical charge. The electrodialysis stack includes alternate layers of anion selective and bipolar membranes. Oxides of nitrogen are removed from the liquid absorbent by air stripping at an elevated temperature and the regenerated liquid absorbent is returned to contact with exhaust gases for removal of sulfur oxides and nitrogen oxides.

  2. Sonic Anemometry to Measure Natural Ventilation in Greenhouses

    PubMed Central

    López, Alejandro; Valera, Diego Luis; Molina-Aiz, Francisco

    2011-01-01

    The present work has developed a methodology for studying natural ventilation in Mediterranean greenhouses by means of sonic anemometry. In addition, specific calculation programmes have been designed to enable processing and analysis of the data recorded during the experiments. Sonic anemometry allows us to study the direction of the airflow at all the greenhouse vents. Knowing through which vents the air enters and leaves the greenhouse enables us to establish the airflow pattern of the greenhouse under natural ventilation conditions. In the greenhouse analysed in this work for Poniente wind (from the southwest), a roof vent designed to open towards the North (leeward) could allow a positive interaction between the wind and stack effects, improving the ventilation capacity of the greenhouse. The cooling effect produced by the mass of turbulent air oscillating between inside and outside the greenhouse at the side vents was limited to 2% (for high wind speed, uo ≥ 4 m s−1) reaching 36.3% when wind speed was lower (uo = 2 m s−1). PMID:22163728

  3. Sonic anemometry to measure natural ventilation in greenhouses.

    PubMed

    López, Alejandro; Valera, Diego Luis; Molina-Aiz, Francisco

    2011-01-01

    The present work has developed a methodology for studying natural ventilation in Mediterranean greenhouses by means of sonic anemometry. In addition, specific calculation programmes have been designed to enable processing and analysis of the data recorded during the experiments. Sonic anemometry allows us to study the direction of the airflow at all the greenhouse vents. Knowing through which vents the air enters and leaves the greenhouse enables us to establish the airflow pattern of the greenhouse under natural ventilation conditions. In the greenhouse analysed in this work for Poniente wind (from the southwest), a roof vent designed to open towards the North (leeward) could allow a positive interaction between the wind and stack effects, improving the ventilation capacity of the greenhouse. The cooling effect produced by the mass of turbulent air oscillating between inside and outside the greenhouse at the side vents was limited to 2% (for high wind speed, u(o) ≥ 4 m s(-1)) reaching 36.3% when wind speed was lower (u(o) = 2 m s(-1)).

  4. 40 CFR 60.713 - Compliance provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... such as drying ovens. All ventilation air must be vented through stacks suitable for testing; (iii... procedures of paragraph (b)(1), (b)(2), (b)(3), or (b)(4) of this section, as appropriate. (2) To establish...) and (v) of this section, as applicable, and the test methods and procedures specified in § 60.715(b...

  5. 40 CFR 60.713 - Compliance provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... such as drying ovens. All ventilation air must be vented through stacks suitable for testing; (iii... procedures of paragraph (b)(1), (b)(2), (b)(3), or (b)(4) of this section, as appropriate. (2) To establish...) and (v) of this section, as applicable, and the test methods and procedures specified in § 60.715(b...

  6. Confined space ventilation by shipyard welders: observed use and effectiveness.

    PubMed

    Pouzou, Jane G; Warner, Chris; Neitzel, Richard L; Croteau, Gerry A; Yost, Michael G; Seixas, Noah S

    2015-01-01

    Shipbuilding involves intensive welding activities within enclosed and confined spaces, and although ventilation is commonly used in the industry, its use and effectiveness has not been adequately documented. Workers engaged in welding in enclosed or confined spaces in two shipyards were observed for their use of ventilation and monitored for their exposure to particulate matter. The type of ventilation in use, its placement and face velocity, the movement of air within the space, and other ventilation-related parameters were recorded, along with task characteristics such as the type of welding, the welder's position, and the configuration of the space. Mechanical ventilation was present in about two-thirds of the 65 welding scenarios observed, with exhaust ventilation used predominantly in one shipyard and supply blowers predominantly in the other. Welders were observed working in apparent dead-spaces within the room in 53% of the cases, even where ventilation was in use. Respiratory protection was common in the two shipyards, observed in use in 77 and 100% of the cases. Welding method, the proximity of the welder's head to the fume, and air mixing were found to be significantly associated with the welder's exposure, while other characteristics of dilution ventilation did not produce appreciable differences in exposure level. These parameters associated with exposure reduction can be assessed subjectively and are thus good candidates for training on effective ventilation use during hot work in confined spaces. Ventilation used in confined space welding is often inadequate for controlling exposure to welding fume. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poppiti, James; Nelson, Roger; MacMillan, Walter J.

    The Waste Isolation Pilot Plant (WIPP) is a 655-meter deep mine near Carlsbad, New Mexico, used to dispose the nation’s defense transuranic waste. Limited airborne radioactivity was released from a container of radioactive waste in WIPP on 14 February, 2014. As designed, a mine ventilation filtration system prevented the large scale release of contamination from the underground. However, isolation dampers leaked, which allowed the release of low levels of contaminants after the event until they were sealed. None of the exposed individuals received any recordable dose. While surface contamination was limited, contamination in the ventilation system and portions of themore » underground was substantial. High efficiency particulate air (HEPA) filters in the operating ventilation system ensure continued containment during recovery and resumption of disposal operations. However, ventilation flow is restricted since the incident, with all exhaust air directed through the filters. Decontamination and natural fixation by the hygroscopic nature of the salt host rock has reduced the likelihood of further contamination spread. Contamination control and ventilation system operability are crucial for resumption of operations. This article provides an operational assessment and evaluation of these two key areas.« less

  8. Vegetative environmental buffers and exhaust fan deflectors for reducing downwind odor and VOCs from tunnel-ventilated swine barns

    USDA-ARS?s Scientific Manuscript database

    Scientists have investigated methods for reducing odor emissions from livestock buildings for decades, yet few technologies have proven effective. Vegetative Environmental Buffers (VEB), which are specially designed combinations of trees, shrubs and grasses, have shown promise in recent years for r...

  9. 29 CFR 1926.57 - Ventilation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... into a duct or hood. It is usually expressed in inches of water gauge. (vii) Exhaust system. A system... velocity. It is usually expressed in inches of water gauge. (xviii) Vertical spindle disc grinder. A... operate the booth without the filters in place. (iv) (A) For wet or water-wash spray booths, the water...

  10. 29 CFR 1926.57 - Ventilation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... into a duct or hood. It is usually expressed in inches of water gauge. (vii) Exhaust system. A system... velocity. It is usually expressed in inches of water gauge. (xviii) Vertical spindle disc grinder. A... operate the booth without the filters in place. (iv) (A) For wet or water-wash spray booths, the water...

  11. 14 CFR 23.1101 - Induction air preheater design.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Induction air preheater design. 23.1101... Induction System § 23.1101 Induction air preheater design. Each exhaust-heated, induction air preheater must be designed and constructed to— (a) Ensure ventilation of the preheater when the induction air...

  12. 14 CFR 23.1101 - Induction air preheater design.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Induction air preheater design. 23.1101... Induction System § 23.1101 Induction air preheater design. Each exhaust-heated, induction air preheater must be designed and constructed to— (a) Ensure ventilation of the preheater when the induction air...

  13. 29 CFR 1915.34 - Mechanical paint removers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Mechanical paint removers. 1915.34 Section 1915.34 Labor... Preservation § 1915.34 Mechanical paint removers. (a) Power tools. (1) Employees engaged in the removal of... confined space, mechanical exhaust ventilation sufficient to keep the dust concentration to a minimum shall...

  14. 14 CFR 23.1101 - Induction air preheater design.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Induction air preheater design. 23.1101... Induction System § 23.1101 Induction air preheater design. Each exhaust-heated, induction air preheater must be designed and constructed to— (a) Ensure ventilation of the preheater when the induction air...

  15. 14 CFR 23.1101 - Induction air preheater design.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction air preheater design. 23.1101... Induction System § 23.1101 Induction air preheater design. Each exhaust-heated, induction air preheater must be designed and constructed to— (a) Ensure ventilation of the preheater when the induction air...

  16. 40 CFR 264.345 - Operating requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... variations in the physical or chemical properties of the waste feed which will not affect compliance with the... (CO) level in the stack exhaust gas; (2) Waste feed rate; (3) Combustion temperature; (4) An appropriate indicator of combustion gas velocity; (5) Allowable variations in incinerator system design or...

  17. THERMAL ENCAPSULATION OF METALS IN SUPERFUND SOILS

    EPA Science Inventory

    Superfund sites frequently contain both heavy metals and organic hazardous waste. If not properly controlled, the metals may be changed to a more leachable form and may also be emitted to the atmosphere via the exhaust stack. This paper documents a batch kiln R&D test program to ...

  18. Classification of Reactor Facility Operational State Using SPRT Methods with Radiation Sensor Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramirez Aviles, Camila A.; Rao, Nageswara S.

    We consider the problem of inferring the operational state of a reactor facility by using measurements from a radiation sensor network, which is deployed around the facility’s ventilation stack. The radiation emissions from the stack decay with distance, and the corresponding measurements are inherently random with parameters determined by radiation intensity levels at the sensor locations. We fuse measurements from network sensors to estimate the intensity at the stack, and use this estimate in a one-sided Sequential Probability Ratio Test (SPRT) to infer the on/off state of the reactor facility. We demonstrate the superior performance of this method over conventionalmore » majority vote fusers and individual sensors using (i) test measurements from a network of NaI sensors, and (ii) emulated measurements using radioactive effluents collected at a reactor facility stack. We analytically quantify the performance improvements of individual sensors and their networks with adaptive thresholds over those with fixed ones, by using the packing number of the radiation intensity space.« less

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rao, Nageswara S.; Ramirez Aviles, Camila A.

    We consider the problem of inferring the operational status of a reactor facility using measurements from a radiation sensor network deployed around the facility’s ventilation off-gas stack. The intensity of stack emissions decays with distance, and the sensor counts or measurements are inherently random with parameters determined by the intensity at the sensor’s location. We utilize the measurements to estimate the intensity at the stack, and use it in a one-sided Sequential Probability Ratio Test (SPRT) to infer on/off status of the reactor. We demonstrate the superior performance of this method over conventional majority fusers and individual sensors using (i)more » test measurements from a network of 21 NaI detectors, and (ii) effluence measurements collected at the stack of a reactor facility. We also analytically establish the superior detection performance of the network over individual sensors with fixed and adaptive thresholds by utilizing the Poisson distribution of the counts. We quantify the performance improvements of the network detection over individual sensors using the packing number of the intensity space.« less

  20. Health-hazard-evaluation report HETA 87-387-2050, Ithaca College, Ithaca, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almaguer, D.; Klein, M.; Klincewicz, S.

    1990-06-01

    In response to a request from an authorized representative of the employees of Ithaca College located in Ithaca, New York, a study was made of possible hazardous conditions at the college stemming from the use of formalin solutions during the embalming and fixing of primates for study. Samples were collected in the anatomy laboratory, the refrigeration room, and the hallway which separated the two rooms. Analyses of the 22 samples collected ranged from nondetectable to 0.12 parts per million for formaldehyde. Two samples which contained quantifiable levels of formaldehyde were collected in the anatomy laboratory. All tests for phenol andmore » ethylene-glycol showed nondetectable levels. Measurements indicated the ventilation system supplied air to the location in line with requirements but that air distribution and exhaust within the laboratory were not conducive to minimizing occupant exposure to contaminants. Only one set of exhaust conditions was under negative pressure. Ventilation may have been inadequate. The staff reported symptoms of headache, sinus congestion, odors in the office, sore throat, and itching and burning eyes. The authors conclude that exposures to low levels of formaldehyde existed at the time of the survey. Formaldehyde levels measured during the study were not deemed high enough to be causing reported symptoms. The authors recommend measures to improve the ventilation system.« less

  1. Effect of Ventilation Strategies on Residential Ozone Levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Iain S.; Sherman, Max H.

    Elevated outdoor ozone levels are associated with adverse health effects. Because people spend the vast majority of their time indoors, reduction in indoor levels of ozone of outdoor origin would lower population exposures and might also lead to a reduction in ozone-associated adverse health effects. In most buildings, indoor ozone levels are diminished with respect to outdoor levels to an extent that depends on surface reactions and on the degree to which ozone penetrates the building envelope. Ozone enters buildings from outdoors together with the airflows that are driven by natural and mechanical means, including deliberate ventilation used to reducemore » concentrations of indoor-generated pollutants. When assessing the effect of deliberate ventilation on occupant health one should consider not only the positive effects on removing pollutants of indoor origin but also the possibility that enhanced ventilation might increase indoor levels of pollutants originating outdoors. This study considers how changes in residential ventilation that are designed to comply with ASHRAE Standard 62.2 might influence indoor levels of ozone. Simulation results show that the building envelope can contribute significantly to filtration of ozone. Consequently, the use of exhaust ventilation systems is predicted to produce lower indoor ozone concentrations than would occur with balanced ventilation systems operating at the same air-­exchange rate. We also investigated a strategy for reducing exposure to ozone that would deliberately reduce ventilation rates during times of high outdoor ozone concentration while still meeting daily average ventilation requirements.« less

  2. Experimental Measurements of the Water Evaporation Rate of a Physical Model

    NASA Astrophysics Data System (ADS)

    Turza, Róbert; Füri, Belo B.

    2017-03-01

    As the number of indoor swimming pools and wellness centers are currently growing, it is necessary to concentrate on the parameters of indoor environments. These parameters are necessary for the design of the HVAC systems that operate these premises. In indoor swimming-pool facilities, the energy demand is large due to ventilation losses from exhaust air. Since water evaporates from a pool's surface, exhaust air has a high water content and specific enthalpy. In this paper the results of the water evaporation rate measured from swimming pool surfaces at higher thermal water temperatures are described.

  3. Indoor air quality in 24 California residences designed as high-performance homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Less, Brennan; Mullen, Nasim; Singer, Brett

    2015-01-01

    Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California. Although the mechanically vented homes were six times as airtight as non-mechanically ventilated homes (medians of 1.1 and 6.1 ACH 50, n=11 and n=8, respectively), their use of mechanical ventilation systems and possiblymore » window operation meant their median air exchange rates were almost the same (0.30 versus 0.32 hr -1, n=8 and n=8, respectively). Pollutant levels were also similar in vented and unvented homes. In addition, these similarities were achieved despite numerous observed faults in complex mechanical ventilation systems. More rigorous commissioning is still recommended. Cooking exhaust systems were used inconsistently and several suffered from design flaws. Failure to follow best practices led to IAQ problems in some cases. Ambient nitrogen dioxide standards were exceeded or nearly so in four homes that either used gas ranges with standing pilots, or in Passive House-style homes that used gas cooking burners without venting range hoods. Homes without active particle filtration had particle count concentrations approximately double those in homes with enhanced filtration. The majority of homes reported using low-emitting materials; consistent with this, formaldehyde levels were approximately half those in conventional, new CA homes built before 2008. Emissions of ultrafine particles (with diameters <100 nm) were dramatically lower on induction electric cooktops, compared with either gas or resistance electric models. These results indicate that high performance homes can achieve acceptable and even exceptional IAQ by providing adequate general mechanical ventilation, using low-emitting materials, providing mechanical particle filtration, incorporating well-designed exhaust ventilation for kitchens and bathrooms, and educating occupants to use the kitchen and bath ventilation.« less

  4. Breath stacking in children with neuromuscular disorders.

    PubMed

    Jenkins, H M; Stocki, A; Kriellaars, D; Pasterkamp, H

    2014-06-01

    Respiratory muscle weakness in neuromuscular disorders (NMD) can lead to shallow breathing and respiratory insufficiency over time. Children with NMD often cannot perform maneuvers to recruit lung volume. In adults, breath stacking with a mask and one-way valve can achieve significantly increased lung volumes. To evaluate involuntary breath stacking (IBS) in NMD, we studied 23 children of whom 15 were cognitively aware and able to communicate verbally. For IBS, a one-way valve and pneumotachograph were attached to a face mask. Tidal volumes (Vt) and minute ventilation (VE ) were calculated from airflow over 30 sec before and after 15 sec of expiratory valve closure. Six cooperative male subjects with Duchenne muscular dystrophy (DMD) participated in a subsequent comparison of IBS with voluntary breath stacking (VBS) and supported breath stacking (SBS). The average Vt in those studied with IBS was 277 ml (range 29-598 ml). The average increase in volume by stacking was 599 ml (range -140 to 2,916 ml) above Vt . The average number of stacked breaths was 4.5 (range 0-17). VE increased on average by 18% after stacking (P < 0.05, paired t-test). Oxygen saturation did not change after stacking. Four of the 23 children did not breath stack. Compared to IBS, VBS achieved similar volumes in the six subjects with DMD but SBS was more successful in those with greatest muscle weakness. IBS may achieve breath volumes of approximately three times Vt and may be particularly useful in non-cooperative subjects with milder degrees of respiratory muscle weakness. © 2013 Wiley Periodicals, Inc.

  5. PCR Testing of a Ventilated Caging System to Detect Murine Fur Mites

    PubMed Central

    Jensen, Eric S; Allen, Kenneth P; Henderson, Kenneth S; Szabo, Aniko; Thulin, Joseph D

    2013-01-01

    Rodents housed in microisolation caging are commonly monitored for infectious agents by the use of soiled bedding sentinels. This strategy relies on the successful transmission of rodent pathogens from the index rodents via soiled bedding to sentinel cages and the subsequent infection or colonization of sentinel rodents. When the prevalence of a pathogen is low or the target agent is not readily transmitted by soiled bedding, alternative testing methodologies should be used. Given the continued prevalence of institutions self-reporting murine fur mites and with the advent of a new sensitive and specific PCR assay for mites, we sought to determine whether the exhaust system of an individual ventilated caging (IVC) system could be used for monitoring the rack's rodent population for mites rather than relying on the responses of sentinels. We deployed single cages of mice (Mus musculus) that were known to be infested with either Radfordia affinis or Myobia musculi on a 70-cage rack, sampled the horizontal exhaust manifolds weekly, and used the new PCR assay to test these samples for mite DNA. We detected the presence of fur mites at a 94.1% probability of detection within 4 wk of placement. Therefore, we recommend swabbing and testing the shelf exhaust manifolds of IVC racks rather than relying on soiled-bedding sentinels as an indicator of the mite status of the rodents on that rack. PMID:23562030

  6. Case study of odor and indoor air quality assessment in the dewatering building at the Stickney Water Reclamation Plant.

    PubMed

    Sharma, Manju; O'Connell, Susan; Garelli, Brett; Sattayatewa, Chakkrid; Moschandreas, Demetrios; Pagilla, Krishna

    2012-01-01

    Indoor air quality (IAQ) and odors were determined using sampling/monitoring, measurement, and modeling methods in a large dewatering building at a very large water reclamation plant. The ultimate goal was to determine control strategies to reduce the sensory impacts on the workforce and achieve odor reduction within the building. Study approaches included: (1) investigation of air mixing by using CO(2) as an indicator, (2) measurement of airflow capacity of ventilation fans, (3) measurement of odors and odorants, (4) development of statistical and IAQ models, and (5) recommendation of control strategies. The results showed that air quality in the building complies with occupational safety and health guidelines; however, nuisance odors that can increase stress and productivity loss still persist. Excess roof fan capacity induced odor dispersion to the upper levels. Lack of a local air exhaust system of sufficient capacity and optimum design was found to be the contributor to occasional less than adequate indoor air quality and odors. Overall, air ventilation rate in the building has less effect on persistence of odors in the building. Odor/odorant emission rates from centrifuge drops were approximately 100 times higher than those from the open conveyors. Based on measurements and modeling, the key control strategies recommended include increasing local air exhaust system capacity and relocation of exhaust hoods closer to the centrifuge drops.

  7. 1. Context view of Building 205, showing hydrogen tanks in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Context view of Building 205, showing hydrogen tanks in foreground and Building 202 exhaust scrubber stack in background. View looking southwest from top of mound east of Building 205. - Rocket Engine Testing Facility, GRC Building No. 205, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  8. 40 CFR 60.717 - Reporting and monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... in § 60.713(b)(1) (liquid material balance); (2) The VOC contained in the coatings for the... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels...

  9. 40 CFR 60.717 - Reporting and monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... in § 60.713(b)(1) (liquid material balance); (2) The VOC contained in the coatings for the... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels...

  10. 40 CFR 60.717 - Reporting and monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... in § 60.713(b)(1) (liquid material balance); (2) The VOC contained in the coatings for the... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels...

  11. 40 CFR 60.717 - Reporting and monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... in § 60.713(b)(1) (liquid material balance); (2) The VOC contained in the coatings for the... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels...

  12. 40 CFR 60.714 - Installation of monitoring devices and recordkeeping.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... by the test method described in § 60.713(b)(1) (liquid material balance) shall maintain records of... equipment controlled by a carbon adsorption system and demonstrating compliance by the procedures described..., as appropriate. (1) For carbon adsorption systems with a common exhaust stack for all the individual...

  13. 40 CFR 60.714 - Installation of monitoring devices and recordkeeping.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... by the test method described in § 60.713(b)(1) (liquid material balance) shall maintain records of... equipment controlled by a carbon adsorption system and demonstrating compliance by the procedures described..., as appropriate. (1) For carbon adsorption systems with a common exhaust stack for all the individual...

  14. 40 CFR 60.714 - Installation of monitoring devices and recordkeeping.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... by the test method described in § 60.713(b)(1) (liquid material balance) shall maintain records of... equipment controlled by a carbon adsorption system and demonstrating compliance by the procedures described..., as appropriate. (1) For carbon adsorption systems with a common exhaust stack for all the individual...

  15. 40 CFR 60.714 - Installation of monitoring devices and recordkeeping.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... by the test method described in § 60.713(b)(1) (liquid material balance) shall maintain records of... equipment controlled by a carbon adsorption system and demonstrating compliance by the procedures described..., as appropriate. (1) For carbon adsorption systems with a common exhaust stack for all the individual...

  16. 40 CFR 60.717 - Reporting and monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... in § 60.713(b)(1) (liquid material balance); (2) The VOC contained in the coatings for the... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels...

  17. 40 CFR 60.714 - Installation of monitoring devices and recordkeeping.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... by the test method described in § 60.713(b)(1) (liquid material balance) shall maintain records of... equipment controlled by a carbon adsorption system and demonstrating compliance by the procedures described..., as appropriate. (1) For carbon adsorption systems with a common exhaust stack for all the individual...

  18. 40 CFR 60.143 - Monitoring of operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... steel production cycle, and the time and duration of any diversion of exhaust gases from the main stack... sensor or pressure tap must be located close to the water discharge point. The Administrator must be consulted for approval in advance of selecting alternative locations for the pressure sensor or tap. (3) All...

  19. 40 CFR 60.143 - Monitoring of operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... steel production cycle, and the time and duration of any diversion of exhaust gases from the main stack... sensor or pressure tap must be located close to the water discharge point. The Administrator must be consulted for approval in advance of selecting alternative locations for the pressure sensor or tap. (3) All...

  20. 40 CFR 52.2276 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... its limestone quarry facilities near New Braunfels, Comal County, Texas shall install fabric filters... of the fabric filters, Parker Brothers and Co., Inc., shall not emit particulate matter in excess of 0.03 grains per standard cubic foot from the exhaust stack of the fabric filter on its primary...

  1. 40 CFR 52.2276 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... its limestone quarry facilities near New Braunfels, Comal County, Texas shall install fabric filters... of the fabric filters, Parker Brothers and Co., Inc., shall not emit particulate matter in excess of 0.03 grains per standard cubic foot from the exhaust stack of the fabric filter on its primary...

  2. 40 CFR 52.2276 - Control strategy and regulations: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... its limestone quarry facilities near New Braunfels, Comal County, Texas shall install fabric filters... of the fabric filters, Parker Brothers and Co., Inc., shall not emit particulate matter in excess of 0.03 grains per standard cubic foot from the exhaust stack of the fabric filter on its primary...

  3. 40 CFR 63.1652 - Emission standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (including primary and tapping) containing particulate matter in excess of one of the following: (1) 0.23... from any existing open submerged arc furnace exhaust gases (including primary and tapping) containing... primary, tapping, and vent stacks) containing particulate matter in excess of 11.2 kg/hr (24.7 lb/hr) when...

  4. 40 CFR 60.5200 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... control if the conditions of paragraph (a)(7)(i)(A) or (a)(7)(i)(B) of this section are met. (A) The zero... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  5. 40 CFR 60.5200 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... control if the conditions of paragraph (a)(7)(i)(A) or (a)(7)(i)(B) of this section are met. (A) The zero... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  6. 40 CFR 60.5200 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... control if the conditions of paragraph (a)(7)(i)(A) or (a)(7)(i)(B) of this section are met. (A) The zero... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  7. Effect of ventilation velocity on hexavalent chromium and isocyanate exposures in aircraft paint spraying.

    PubMed

    Bennett, James; Marlow, David; Nourian, Fariba; Breay, James; Feng, Amy; Methner, Mark

    2018-03-01

    Exposure control system performance was evaluated during aircraft paint spraying at a military facility. Computational fluid dynamics (CFD) modeling, tracer gas testing, and exposure monitoring examined contaminant exposure vs. crossflow ventilation velocity. CFD modeling using the RNG k-ϵ turbulence model showed exposures to simulated methyl isobutyl ketone of 294 and 83.6 ppm, as a spatial average of five worker locations, for velocities of 0.508 and 0.381 m/s (100 and 75 fpm), respectively. In tracer gas experiments, observed supply/exhaust velocities of 0.706/0.503 m/s (136/99 fpm) were termed full-flow, and reduced velocities were termed 3/4-flow and half-flow. Half-flow showed higher tracer gas concentrations than 3/4-flow, which had the lowest time-averaged concentration, with difference in log means significant at the 95% confidence level. Half-flow compared to full-flow and 3/4-flow compared to full-flow showed no statistically significant difference. CFD modeling using these ventilation conditions agreed closely with the tracer results for the full-flow and 3/4-flow comparison, yet not for the 3/4-flow and half-flow comparison. Full-flow conditions at the painting facility produced a velocity of 0.528 m/s (104 fpm) midway between supply and exhaust locations, with the supply rate of 94.4 m 3 /s (200,000 cfm) exceeding the exhaust rate of 68.7 m 3 /s (146,000 cfm). Ventilation modifications to correct this imbalance created a midhangar velocity of 0.406 m/s (80.0 fpm). Personal exposure monitoring for two worker groups-sprayers and sprayer helpers ("hosemen")-compared process duration means for the two velocities. Hexavalent chromium (Cr[VI]) exposures were 500 vs. 360 µg/m 3 for sprayers and 120 vs. 170 µg/m 3 for hosemen, for 0.528 m/s (104 fpm) and 0.406 m/s (80.0 fpm), respectively. Hexamethylene diisocyanate (HDI) monomer means were 32.2 vs. 13.3 µg/m 3 for sprayers and 3.99 vs. 8.42 µg/m 3 for hosemen. Crossflow velocities affected exposures inconsistently, and local work zone velocities were much lower. Aircraft painting contaminant control is accomplished better with the unidirectional crossflow ventilation presented here than with other observed configurations. Exposure limit exceedances for this ideal condition reinforce continued use of personal protective equipment.

  8. Analysis and design of three dimensional supersonic nozzles. Volume 1: Nozzle-exhaust flow field analysis by a reference plane characteristics technique

    NASA Technical Reports Server (NTRS)

    Dash, S.; Delguidice, P.

    1972-01-01

    A second order numerical method employing reference plane characteristics has been developed for the calculation of geometrically complex three dimensional nozzle-exhaust flow fields, heretofore uncalculable by existing methods. The nozzles may have irregular cross sections with swept throats and may be stacked in modules using the vehicle undersurface for additional expansion. The nozzles may have highly nonuniform entrance conditions, the medium considered being an equilibrium hydrogen-air mixture. The program calculates and carries along the underexpansion shock and contact as discrete discontinuity surfaces, for a nonuniform vehicle external flow.

  9. Performance characteristics of axisymmetric convergent-divergent exhaust nozzles with longitudinal slots in the divergent

    NASA Technical Reports Server (NTRS)

    Leavitt, L. D.; Bangert, L. S.

    1982-01-01

    An investigation was conducted in the Langley 16 foot Transonic Tunnel and in the static test facility of that tunnel to determine the effects of divergent flap ventilation of an axisymmetric nozzle on nozzle internal (static) and wind on performance. Tests were conducted at 0 deg angle of attack at static conditions and at Mach numbers from 0.6 to 1.2. Ratios of jet total pressure to free stream static pressure were varied from 1.0 (jet off) to approximately 14.0 depending on Mach number. The results of this study indicate that divergent flap ventilation generally provided large performance benefits at overexpanded nozzle conditions and performance reductions at underexpanded nozzle conditions when compared to the baseline (unventilated) nozzles. Ventilation also reduced the peak static and wind on performance levels.

  10. Evaluation of Passive Vents in New Construction Multifamily Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sean Maxwell; Berger, David; Zuluaga, Marc

    Exhaust ventilation and corresponding outdoor air strategies are being implemented in high performance, new construction, multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards.

  11. Control of workers’ exposure to xylene in a pesticide production factory

    PubMed Central

    Mohammadyan, M; Baharfar, Y

    2015-01-01

    Background: Acute and chronic exposure to xylene can result in a range of negative health effects. However, xylene is widely used and emitted in the air of workplaces. Objectives: To evaluate xylene vapor concentrations to guide the design and evaluation of a local exhaust ventilation (LEV) system to reduce exposure in a pesticide production factory. Method: A real time volatile organic compound (VOC) monitor was used to determine the workers’ time-weighted average (TWA) exposure. A LEV system was designed, and then, workers’ exposure to xylene vapor was evaluated. Results: We found that worker’s exposure to xylene (4.7±5.5 ppm) was lower than the standards recommended by the American Conference of Governmental Industrial Hygienists (ACGIH) and the Occupational safety and health administration (OSHA). Despite the low TWA exposures, the short-term exposures for some workers were higher than STEL levels. Three canopy hoods were designed and installed with capture velocities of 0.508 m second−1 and duct velocity of 10.16 m second−1. Conclusion: We found that an exhaust ventilation system had a significantly reduced occupational exposure to xylene vapor. PMID:25487643

  12. Effect of forced-air warming on the performance of operating theatre laminar flow ventilation.

    PubMed

    Dasari, K B; Albrecht, M; Harper, M

    2012-03-01

    Forced-air warming exhaust may disrupt operating theatre airflows via formation of convection currents, which depends upon differences in exhaust and operating room air temperatures. We investigated whether the floor-to-ceiling temperatures around a draped manikin in a laminar-flow theatre differed when using three types of warming devices: a forced-air warming blanket (Bair Hugger™); an over-body conductive blanket (Hot Dog™); and an under-body resistive mattress (Inditherm™). With forced-air warming, mean (SD) temperatures were significantly elevated over the surgical site vs those measured with the conductive blanket (+2.73 (0.7) °C; p<0.001) or resistive mattress (+3.63 (0.7) °C; p<0.001). Air temperature differences were insignificant between devices at floor (p=0.339), knee (p=0.799) and head height levels (p=0.573). We conclude that forced-air warming generates convection current activity in the vicinity of the surgical site. The clinical concern is that these currents may disrupt ventilation airflows intended to clear airborne contaminants from the surgical site. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.

  13. Engineering controls for furniture strippers to meet the OSHA methylene chloride PEL.

    PubMed

    Estill, Cheryl Fairfield; Watkins, Daniel S; Shulman, Stanley A; Kurimo, Robert W; Kovein, Ronald J

    2002-01-01

    This case study demonstrates how methylene chloride exposures during furniture stripping can be reduced to below the Occupational Safety and Health Administration (OSHA) permissible exposure limit (PEL) of 25 ppm (as an 8-hour time-weighted average). Five surveys were conducted at one facility; the first four resulted in employee exposure geometric means from 39 to 332 ppm. For the fifth survey local exhaust ventilation was used at the stripping tank and the rinsing area, which together exhausted 138 m3/min (4860 ft3/min). Additional controls included providing adequate make-up air, adding paraffin wax to the stripping solution, raising the level of the stripping solution in the tank, and discussing good work practices with the employee. The employees' methylene chloride exposures during the fifth survey resulted in a geometric mean of 5.6 ppm with a 95% upper confidence limit of 8.3 ppm, which was found to be significantly lower than the OSHA PEL and the OSHA action level of 12.5 ppm. The cost of the ventilation system was $8900.

  14. Indoor thermal environment, air exchange rates, and carbon dioxide concentrations before and after energy retro fits in Finnish and Lithuanian multi-family buildings.

    PubMed

    Leivo, Virpi; Prasauskas, Tadas; Du, Liuliu; Turunen, Mari; Kiviste, Mihkel; Aaltonen, Anu; Martuzevicius, Dainius; Haverinen-Shaughnessy, Ulla

    2018-04-15

    Impacts of energy retrofits on indoor thermal environment, i.e. temperature (T) and relative humidity (RH), as well as ventilation rates and carbon dioxide (CO 2 ) concentrations, were assessed in 46 Finnish and 20 Lithuanian multi-family buildings, including 39 retrofitted case buildings in Finland and 15 in Lithuania (the remaining buildings were control buildings with no retrofits). In the Finnish buildings, high indoor T along with low RH levels was commonly observed both before and after the retrofits. Ventilation rates (l/s per person) were higher after the retrofits in buildings with mechanical exhaust ventilation than the corresponding values before the retrofits. Measured CO 2 levels were low in vast majority of buildings. In Lithuania, average indoor T levels were low before the retrofits and there was a significant increase in the average T after the retrofits. In addition, average ventilation rate was lower and CO 2 levels were higher after the retrofits in the case buildings (N=15), both in apartments with natural and mixed ventilation. Based on the results, assessment of thermal conditions and ventilation rates after energy retrofits is crucial for optimal indoor environmental quality and energy use. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Influence of Applying Additional Forcing Fans for the Air Distribution in Ventilation Network

    NASA Astrophysics Data System (ADS)

    Szlązak, Nikodem; Obracaj, Dariusz; Korzec, Marek

    2016-09-01

    Mining progress in underground mines cause the ongoing movement of working areas. Consequently, it becomes necessary to adapt the ventilation network of a mine to direct airflow into newly-opened districts. For economic reasons, opening new fields is often achieved via underground workings. Length of primary intake and return routes increases and also increases the total resistance of a complex ventilation network. The development of a subsurface structure can make it necessary to change the air distribution in a ventilation network. Increasing airflow into newly-opened districts is necessary. In mines where extraction does not entail gas-related hazards, there is possibility of implementing a push-pull ventilation system in order to supplement airflows to newly developed mining fields. This is achieved by installing subsurface fan stations with forcing fans at the bottom of downcast shaft. In push-pull systems with multiple main fans, it is vital to select forcing fans with characteristic curves matching those of the existing exhaust fans to prevent undesirable mutual interaction. In complex ventilation networks it is necessary to calculate distribution of airflow (especially in networks with a large number of installed fans). In the article the influence of applying additional forcing fans for the air distribution in ventilation network for underground mine were considered. There are also analysed the extent of overpressure caused by the additional forcing fan in branches of the ventilation network (the operating range of additional forcing fan). Possibilities of increasing airflow rate in working areas were conducted.

  16. Use of Recirculating Ventilation with Dust Filtration to Improve Wintertime Air Quality in a Swine Farrowing Room

    PubMed Central

    Anthony, T. Renée; Altmaier, Ralph; Jones, Samuel; Gassman, Rich; Park, Jae Hong; Peters, Thomas M.

    2016-01-01

    The performance of a recirculating ventilation system with dust filtration was evaluated to determine its effectiveness to improve the air quality in a swine farrowing room of a concentrated animal feeding operation (CAFO). Air was exhausted from the room (0.47 m3sec−1; 1000 cfm), treated with a filtration unit (Shaker-Dust Collector), and returned to the farrowing room to reduce dust concentrations while retaining heat necessary for livestock health. The air quality in the room was assessed over a winter, during which time limited fresh air is traditionally brought into the building. Over the study period, dust concentrations ranged from 0.005 to 0.31 mg m−3 (respirable) and 0.17 to 2.09 mg m−3 (inhalable). In-room dust concentrations were reduced (41% for respirable and 33% for inhalable) with the system in operation, while gas concentrations (ammonia [NH3], hydrogen sulfide [H2S], carbon monoxide [CO], carbon dioxide [CO2]) were unchanged. The position of the exhaust and return air systems provided reasonably uniform contaminant distributions, although the respirable dust concentrations nearest one of the exhaust ducts was statistically higher than other locations in the room, with differences averaging only 0.05 mg m−3. Throughout the study, CO2 concentrations consistently exceeded 1540 ppm (industry recommendations) and on eight of the 18 study days it exceeded 2500 ppm (50% of the ACGIH TLV), with significantly higher concentrations near a door to a temperature-controlled hallway that was typically often left open. Alternative heaters are recommended to reduce CO2 concentrations in the room. Contaminant concentrations were modeled using production and environmental factors, with NH3 related to the number of sow in the room and outdoor temperatures and CO2 related to the number of piglets and outdoor temperatures. The recirculating ventilation system provided dust reduction without increasing concentrations of hazardous gases. PMID:25950713

  17. Modeling Environmental Tobacco Smoke (ETS) Infiltration in Low-Income Multifamily Housing before and after Building Energy Retrofits

    PubMed Central

    Fabian, Maria Patricia; Lee, Sharon Kitman; Underhill, Lindsay Jean; Vermeer, Kimberly; Adamkiewicz, Gary; Levy, Jonathan Ian

    2016-01-01

    Secondhand exposure to environmental tobacco smoke (ETS) in multifamily housing remains a health concern despite strong recommendations to implement non-smoking policies. Multiple studies have documented exposure to ETS in non-smoking units located in buildings with smoking units. However, characterizing the magnitude of ETS infiltration or measuring the impact of building interventions or resident behavior on ETS is challenging due to the complexities of multifamily buildings, which include variable resident behaviors and complex airflows between numerous shared compartments (e.g., adjacent apartments, common hallways, elevators, heating, ventilating and air conditioning (HVAC) systems, stack effect). In this study, building simulation models were used to characterize changes in ETS infiltration in a low income, multifamily apartment building in Boston which underwent extensive building renovations targeting energy savings. Results suggest that exterior wall air sealing can lead to increases in ETS infiltration across apartments, while compartmentalization can reduce infiltration. The magnitude and direction of ETS infiltration depends on apartment characteristics, including construction (i.e., level and number of exterior walls), resident behavior (e.g., window opening, operation of localized exhaust fans), and seasonality. Although overall ETS concentrations and infiltration were reduced post energy-related building retrofits, these trends were not generalizable to all building units. Whole building smoke-free policies are the best approach to eliminate exposure to ETS in multifamily housing. PMID:26999174

  18. Modeling Environmental Tobacco Smoke (ETS) Infiltration in Low-Income Multifamily Housing before and after Building Energy Retrofits.

    PubMed

    Fabian, Maria Patricia; Lee, Sharon Kitman; Underhill, Lindsay Jean; Vermeer, Kimberly; Adamkiewicz, Gary; Levy, Jonathan Ian

    2016-03-16

    Secondhand exposure to environmental tobacco smoke (ETS) in multifamily housing remains a health concern despite strong recommendations to implement non-smoking policies. Multiple studies have documented exposure to ETS in non-smoking units located in buildings with smoking units. However, characterizing the magnitude of ETS infiltration or measuring the impact of building interventions or resident behavior on ETS is challenging due to the complexities of multifamily buildings, which include variable resident behaviors and complex airflows between numerous shared compartments (e.g., adjacent apartments, common hallways, elevators, heating, ventilating and air conditioning (HVAC) systems, stack effect). In this study, building simulation models were used to characterize changes in ETS infiltration in a low income, multifamily apartment building in Boston which underwent extensive building renovations targeting energy savings. Results suggest that exterior wall air sealing can lead to increases in ETS infiltration across apartments, while compartmentalization can reduce infiltration. The magnitude and direction of ETS infiltration depends on apartment characteristics, including construction (i.e., level and number of exterior walls), resident behavior (e.g., window opening, operation of localized exhaust fans), and seasonality. Although overall ETS concentrations and infiltration were reduced post energy-related building retrofits, these trends were not generalizable to all building units. Whole building smoke-free policies are the best approach to eliminate exposure to ETS in multifamily housing.

  19. Pneumothorax as a complication of lung volume recruitment.

    PubMed

    Westermann, Erik J A; Jans, Maurice; Gaytant, Michael A; Bach, John R; Kampelmacher, Mike J

    2013-01-01

    Lung volume recruitment involves deep inflation techniques to achieve maximum insufflation capacity in patients with respiratory muscle weakness, in order to increase peak cough flow, thus helping to maintain airway patency and improve ventilation. One of these techniques is air stacking, in which a manual resuscitator is used in order to inflate the lungs. Although intrathoracic pressures can rise considerably, there have been no reports of respiratory complications due to air stacking. However, reaching maximum insufflation capacity is not recommended in patients with known structural abnormalities of the lungs or chronic obstructive airway disease. We report the case of a 72-year-old woman who had poliomyelitis as a child, developed torsion scoliosis and post-polio syndrome, and had periodic but infrequent asthma attacks. After performing air stacking for 3 years, the patient suddenly developed a pneumothorax, indicating that this technique should be used with caution or not at all in patients with a known pulmonary pathology.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrews, V.E.

    Naturally occurring radioactivity was measured in the atmospheric emissions and process materials of a thermal phosphate (elemental phosphorus) plant. Representative exhaust stack samples were collected from each process in the plant. The phosphate ore contained 12 to 20 parts per million uranium. Processes, emission points, and emission controls are described. Radioactivity concentrations and emission rates from the sources sampled are given.

  1. Influence of continuous mining arrangements on respirable dust exposures

    PubMed Central

    Beck, T. W.; Organiscak, J. A.; Pollock, D. E.; Potts, J. D.; Reed, W. R.

    2017-01-01

    In underground continuous mining operations, ventilation, water sprays and machine-mounted flooded-bed scrubbers are the primary means of controlling respirable dust exposures at the working face. Changes in mining arrangements — such as face ventilation configuration, orientation of crosscuts mined in relation to the section ventilation and equipment operator positioning — can have impacts on the ability of dust controls to reduce occupational respirable dust exposures. This study reports and analyzes dust concentrations measured by the Pittsburgh Mining Research Division for remote-controlled continuous mining machine operators as well as haulage operators at 10 U.S. underground mines. The results of these respirable dust surveys show that continuous miner exposures varied little with depth of cut but are significantly higher with exhaust ventilation. Haulage operators experienced elevated concentrations with blowing face ventilation. Elevated dust concentrations were observed for both continuous miner operators and haulage operators when working in crosscuts driven into or counter to the section airflow. Individual cuts are highlighted to demonstrate instances of minimal and excessive dust exposures attributable to particular mining configurations. These findings form the basis for recommendations for lowering face worker respirable dust exposures. PMID:28529441

  2. Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent). The original ventilation design for the project was provided by a local engineer and consisted of a single large heat recovery ventilator (HRV) located in a mechanical room in the basementmore » with a centralized duct system providing supply air to the main living space and exhausting stale air from the single bathroom in each apartment. This design was deemed to be far too costly to install and operate for several reasons: the large central HRV was oversized and the specified flows to each apartment were much higher than the ASHRAE 62.2 rate; an extensive system of ductwork, smoke and fire dampers, and duct chases were specified; ductwork required a significant area of dropped ceilings; and the system lacked individual ventilation control in the apartments« less

  3. False-positive results after environmental pinworm PCR testing due to Rhabditid nematodes in Corncob bedding.

    PubMed

    Leblanc, Mathias; Berry, Kristina; Graciano, Sandy; Becker, Brandon; Reuter, Jon D

    2014-11-01

    Modern rodent colonies are housed in individually ventilated cages to protect the animals from contamination with adventitious pathogens. Standard health monitoring through soiled-bedding sentinels does not always detect infections, especially in the context of low pathogen prevalence. Recently proposed alternatives include analyzing environmental samples from the cages or rack exhaust by PCR to improve the detection of rodent pathogens but optimal sampling strategies have not yet been established for different microorganisms. Although generally very sensitive and specific, these molecular assays are not foolproof and subject to false-positive and -negative results and should always be interpreted cautiously with an overall understanding of the intrinsic controls and all the variables that may affect the results. Here, we report a limited Aspiculuris tetraptera outbreak in a mouse barrier facility that was detected by fecal PCR in sentinels and confirmed by fecal flotation and direct cecal examination of both sentinels and colony animals. The outbreak led to a widespread survey of all facilities for pinworms by using environmental PCR from ventilated rack exhaust plenums. Environmental PCR suggested an unexpected widespread contamination of all ventilated racks holding nonautoclaved cages, but results could not be confirmed in sentinel or colony animals by fecal flotation, cecal and colonic examination, or cage PCR testing. After additional investigation, the unexpected environmental PCR results were confirmed as false-positive findings due to the nonspecificity of the assay, leading to the amplification of rhabditid nematodes, which are not infectious in rodents but which contaminated the corncob bedding.

  4. Drilling side holes from a borehole

    NASA Technical Reports Server (NTRS)

    Collins, E. R., Jr.

    1980-01-01

    Machine takes long horizontal stratum samples from confines of 21 cm bore hole. Stacked interlocking half cylindrical shells mate to form rigid thrust tube. Drive shaft and core storage device is flexible and retractable. Entire machine fits in 10 meter length of steel tube. Machine could drill drainage or ventilation holes in coal mines, or provide important information for geological, oil, and geothermal surveys.

  5. 77 FR 28626 - Biweekly Notice, Applications and Amendments to Facility Operating Licenses and Combined Licenses...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-15

    ... Water System, the Auxiliary Building Filtered Ventilation Exhaust System, or the Diesel Generators... nuclear service water system (NSWS) for a time period of 14 days. Basis for proposed no significant... the diesel generator buildings in the event of a leak or a break in the system piping. The probability...

  6. Engine Performance (Section C: Emission Control Systems). Auto Mechanics Curriculum Guide. Module 3. Instructor's Guide.

    ERIC Educational Resources Information Center

    Rains, Larry

    This engine performance (emission control systems) module is one of a series of competency-based modules in the Missouri Auto Mechanics Curriculum Guide. Topics of this module's five units are: positive crankcase ventilation (PCV) and evaporative emission control systems; exhaust gas recirculation (EGR); air injection and catalytic converters;…

  7. The National Shipbuilding Research Program. Impact of Recent and Anticipated Changes in Airborne Emission Exposure Limits on Shipyard Workers

    DTIC Science & Technology

    1996-03-01

    shipyard welders performing GTAW of stainless steels and high chromium nickel alloys are above 0.25 µg/m3 without use of local exhaust ventilation. Local...Manganese, Chromium , and Hexavalent Chromium May Be Encountered...66 5.1 Reduction of Nickel and Hexavalent Chromium Emissions Through

  8. Three dimensional nozzle-exhaust flow field analysis by a reference plane technique.

    NASA Technical Reports Server (NTRS)

    Dash, S. M.; Del Guidice, P. D.

    1972-01-01

    A numerical method based on reference plane characteristics has been developed for the calculation of highly complex supersonic nozzle-exhaust flow fields. The difference equations have been developed for three coordinate systems. Local reference plane orientations are employed using the three coordinate systems concurrently thus catering to a wide class of flow geometries. Discontinuities such as the underexpansion shock and contact surfaces are computed explicitly for nonuniform vehicle external flows. The nozzles considered may have irregular cross-sections with swept throats and may be stacked in modules using the vehicle undersurface for additional expansion. Results are presented for several nozzle configurations.

  9. 40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... a bag leak detection system as specified in paragraphs (b)(1) through (8) of this section. (1) You must install and operate a bag leak detection system for each exhaust stack of the fabric filter. (2) Each bag leak detection system must be installed, operated, calibrated, and maintained in a manner...

  10. 40 CFR 62.14690 - What monitoring equipment must I install and what parameters must I monitor?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... subpart, you must install, calibrate, maintain, and continuously operate a bag leak detection system as... detection system for each exhaust stack of the fabric filter. (2) Each bag leak detection system must be... specifications and recommendations. (3) The bag leak detection system must be certified by the manufacturer to be...

  11. 5. VIEW TO THE EAST NORTH EAST FROM PEAK OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. VIEW TO THE EAST NORTH EAST FROM PEAK OF THE TURBINE HALL. THE BRICK STACK TO THE RIGHT EXHAUSTED BOILER 904 WHICH WAS INSTALLED IN 1944. STEEL SHEATHED STRUCTURE IN CENTER OF PHOTOGRAPH HOUSED BOILERS 902 AND 903. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  12. 13. View north within enclosure between old and new sections ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. View north within enclosure between old and new sections of Armory Street Pump House. Object at is a muffler and exhaust stack for the turbine powered stand-by generator unit. - Lake Whitney Water Filtration Plant, Armory Street Pumphouse, North side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  13. Implications of Natural Occlusion of Ventilated Racks on Ammonia and Sanitation Practices

    PubMed Central

    Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M

    2014-01-01

    Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague–Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded. PMID:24602544

  14. Implications of natural occlusion of ventilated racks on ammonia and sanitation practices.

    PubMed

    Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M

    2014-03-01

    Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague-Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded.

  15. Hard metal exposures. Part 1: Observed performance of three local exhaust ventilation systems.

    PubMed

    Guffey, S E; Simcox, N; Booth, D W; Hibbard, R; Stebbins, A

    2000-04-01

    Not every ventilation system performs as intended; much can be learned when they do not. The purpose of this study was to compare observed initial performance to expected levels for three saw-reconditioning shop ventilation systems and to characterize the changes in performance of the systems over a one-year period. These three local exhaust ventilation systems were intended to control worker exposures to cobalt, cadmium, and chromium during wet grinding, dry grinding, and welding/brazing activities. Prior to installation the authors provided some design guidance based on Industrial Ventilation, a Manual of Recommended Practice. However, the authors had limited influence on the actual installation and operation and no line authority for the systems. In apparent efforts to cut costs and to respond to other perceived needs, the installed systems deviated from the specifications used in pressure calculations in many important aspects, including adding branch ducts, use of flexible ducts, the choice of fans, and the construction of some hoods. After installation of the three systems, ventilation measurements were taken to determine if the systems met design specifications, and worker exposures were measured to determine effectiveness. The results of the latter will be published as a companion article. The deviations from design and maintenance failures may have adversely affected performance. From the beginning to the end of the study period the distribution of air flow never matched the design specifications for the systems. The observed air flows measured within the first month of installation did not match the predicated design air flows for any of the systems, probably because of the differences between the design and the installed system. Over the first year of operation, hood air flow variability was high due to inadequate cleaning of the sticky process materials which rapidly accumulated in the branch ducts. Poor distribution of air flows among branch ducts frequently produced individual hood air flows that were far below specified design levels even when the total air flow through that system was more than adequate. To experienced practitioners, it is not surprising that deviations from design recommendations and poor maintenance would be associated with poor system performance. Although commonplace, such experiences have not been documented in peer-reviewed publications to date. This publication is a first step in providing that documentation.

  16. Lighting system combining daylight concentrators and an artificial source

    DOEpatents

    Bornstein, Jonathan G.; Friedman, Peter S.

    1985-01-01

    A combined lighting system for a building interior includes a stack of luminescent solar concentrators (LSC), an optical conduit made of preferably optical fibers for transmitting daylight from the LSC stack, a collimating lens set at an angle, a fixture for receiving the daylight at one end and for distributing the daylight as illumination inside the building, an artificial light source at the other end of the fixture for directing artifical light into the fixture for distribution as illumination inside the building, an automatic dimmer/brightener for the artificial light source, and a daylight sensor positioned near to the LSC stack for controlling the automatic dimmer/brightener in response to the daylight sensed. The system also has a reflector positioned behind the artificial light source and a fan for exhausting heated air out of the fixture during summer and for forcing heated air into the fixture for passage into the building interior during winter.

  17. Source apportionment of stack emissions from research and development facilities using positive matrix factorization

    NASA Astrophysics Data System (ADS)

    Ballinger, Marcel Y.; Larson, Timothy V.

    2014-12-01

    Research and development (R&D) facility emissions are difficult to characterize due to their variable processes, changing nature of research, and large number of chemicals. Positive matrix factorization (PMF) was applied to volatile organic compound (VOC) concentrations measured in the main exhaust stacks of four different R&D buildings to identify the number and composition of major contributing sources. PMF identified between 9 and 11 source-related factors contributing to stack emissions, depending on the building. Similar factors between buildings were major contributors to trichloroethylene (TCE), acetone, and ethanol emissions; other factors had similar profiles for two or more buildings but not all four. At least one factor for each building was identified that contained a broad mix of many species and constraints were used in PMF to modify the factors to resemble more closely the off-shift concentration profiles. PMF accepted the constraints with little decrease in model fit.

  18. In-depth survey report of American Airlines plating facility

    NASA Astrophysics Data System (ADS)

    Mortimer, V. D., Jr.

    1982-12-01

    An in depth survey was conducted at the American Airlines Maintenance and Engineering Center as part of National Institute for Occupational Safety and Health (NIOSH) study evaluating measures to control occupational health hazards associated with the metal plating industry. This American Airlines plating facility, employing approximately 25 workers, is primarily engaged in plating hard chromium, nickel and cadmium on aircraft engine and landing gear parts. Six tanks were studied, including an electroless nickel tank. Area and personal samples for chromium, nickel, cadmium, and cyanide were collected. Ventilation airflow and tank dimensions were measured and data recorded on plating operations. The relationships between air contaminants emitted, local exhaust ventilation flow rate, tank size, and plating activity were evaluated.

  19. The impact of particle filtration on indoor air quality in a classroom near a highway.

    PubMed

    van der Zee, S C; Strak, M; Dijkema, M B A; Brunekreef, B; Janssen, N A H

    2017-03-01

    A pilot study was performed to investigate whether the application of a new mechanical ventilation system with a fine F8 (MERV14) filter could improve indoor air quality in a high school near the Amsterdam ring road. PM10, PM2.5, and black carbon (BC) concentrations were measured continuously inside an occupied intervention classroom and outside the school during three sampling periods in the winter of 2013/2014. Initially, 3 weeks of baseline measurements were performed, with the existing ventilation system and normal ventilation habits. Next, an intervention study was performed. A new ventilation system was installed in the classroom, and measurements were performed during 8 school weeks, in alternating 2-week periods with and without the filter in the ventilation system under otherwise identical ventilation conditions. Indoor/outdoor ratios measured during the weeks with filter were compared with those measured without filter to evaluate the ability of the F8 filter to improve indoor air quality. During teaching hours, the filter reduced BC exposure by, on average, 36%. For PM10 and PM2.5, a reduction of 34% and 30% was found, respectively. This implies that application of a fine filter can reduce the exposure of schoolchildren to traffic exhaust at hot spot locations by about one-third. © 2016 The Authors. Indoor Air published by John Wiley & Sons Ltd.

  20. 29 CFR 1917.152 - Welding, cutting and heating (hot work) 12 (See also § 1917.2, definition of Hazardous cargo...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reflective surfaces. (iv) Inert-gas metal-arc welding on stainless steel shall not be performed unless..., fumes and smoke below a hazardous level. (ii) Local exhaust ventilation shall consist of movable hoods... not exposed to hazardous levels of fumes: (A) Lead base metals; (B) Cadmium-bearing filler materials...

  1. 29 CFR 1917.152 - Welding, cutting and heating (hot work) 12 (See also § 1917.2, definition of Hazardous cargo...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reflective surfaces. (iv) Inert-gas metal-arc welding on stainless steel shall not be performed unless..., fumes and smoke below a hazardous level. (ii) Local exhaust ventilation shall consist of movable hoods... not exposed to hazardous levels of fumes: (A) Lead base metals; (B) Cadmium-bearing filler materials...

  2. 29 CFR 1917.152 - Welding, cutting and heating (hot work) 12 (See also § 1917.2, definition of Hazardous cargo...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reflective surfaces. (iv) Inert-gas metal-arc welding on stainless steel shall not be performed unless..., fumes and smoke below a hazardous level. (ii) Local exhaust ventilation shall consist of movable hoods... not exposed to hazardous levels of fumes: (A) Lead base metals; (B) Cadmium-bearing filler materials...

  3. Four-dimensional optical coherence tomography imaging of total liquid ventilated rats

    NASA Astrophysics Data System (ADS)

    Kirsten, Lars; Schnabel, Christian; Gaertner, Maria; Koch, Edmund

    2013-06-01

    Optical coherence tomography (OCT) can be utilized for the spatially and temporally resolved visualization of alveolar tissue and its dynamics in rodent models, which allows the investigation of lung dynamics on the microscopic scale of single alveoli. The findings could provide experimental input data for numerical simulations of lung tissue mechanics and could support the development of protective ventilation strategies. Real four-dimensional OCT imaging permits the acquisition of several OCT stacks within one single ventilation cycle. Thus, the entire four-dimensional information is directly obtained. Compared to conventional virtual four-dimensional OCT imaging, where the image acquisition is extended over many ventilation cycles and is triggered on pressure levels, real four-dimensional OCT is less vulnerable against motion artifacts and non-reproducible movement of the lung tissue over subsequent ventilation cycles, which widely reduces image artifacts. However, OCT imaging of alveolar tissue is affected by refraction and total internal reflection at air-tissue interfaces. Thus, only the first alveolar layer beneath the pleura is visible. To circumvent this effect, total liquid ventilation can be carried out to match the refractive indices of lung tissue and the breathing medium, which improves the visibility of the alveolar structure, the image quality and the penetration depth and provides the real structure of the alveolar tissue. In this study, a combination of four-dimensional OCT imaging with total liquid ventilation allowed the visualization of the alveolar structure in rat lung tissue benefiting from the improved depth range beneath the pleura and from the high spatial and temporal resolution.

  4. Reanalysis of Diesel Engine Exhaust and Lung Cancer Mortality in the Diesel Exhaust in Miners Study Cohort Using Alternative Exposure Estimates and Radon Adjustment.

    PubMed

    Chang, Ellen T; Lau, Edmund C; Van Landingham, Cynthia; Crump, Kenny S; McClellan, Roger O; Moolgavkar, Suresh H

    2018-06-01

    The Diesel Exhaust in Miners Study (DEMS) (United States, 1947-1997) reported positive associations between diesel engine exhaust exposure, estimated as respirable elemental carbon (REC), and lung cancer mortality. This reanalysis of the DEMS cohort used an alternative estimate of REC exposure incorporating historical data on diesel equipment, engine horsepower, ventilation rates, and declines in particulate matter emissions per horsepower. Associations with cumulative REC and average REC intensity using the alternative REC estimate and other exposure estimates were generally attenuated compared with original DEMS REC estimates. Most findings were statistically nonsignificant; control for radon exposure substantially weakened associations with the original and alternative REC estimates. No association with original or alternative REC estimates was detected among miners who worked exclusively underground. Positive associations were detected among limestone workers, whereas no association with REC or radon was found among workers in the other 7 mines. The differences in results based on alternative exposure estimates, control for radon, and stratification by worker location or mine type highlight areas of uncertainty in the DEMS data.

  5. The effect on quality of chest compressions and exhaustion of a compression--ventilation ratio of 30:2 versus 15:2 during cardiopulmonary resuscitation--a randomised trial.

    PubMed

    Deschilder, Koen; De Vos, Rien; Stockman, Willem

    2007-07-01

    Recent cardio pulmonary resuscitation (CPR) guidelines changed the compression:ventilation ratio in 30:2. To compare the quality of chest compressions and exhaustion using the ratio 30:2 versus 15:2. A prospective, randomised crossover design was used. Subjects were recruited from the H.-Hart hospital personnel and the University College Katho for nurses and bio-engineering. Each participant performed 5min of CPR using either the ratio 30:2 or 15:2, then after a 15min rest switched to the other ratio. The data were collected using a questionnaire and an adult resuscitation manikin. The outcomes included exhaustion as measured by a visual analogue scale (VAS) score, depth of chest compressions, rates of chest compressions, total number of chest compressions, number of correct chest compressions and incomplete release. Data were compared using the Wilcoxon Signed Ranks Test. The results are presented as medians and interquartile ranges (IQR). One hundred and thirty subjects completed the study. The exhaustion-score using the VAS was 5.9 (IQR 2.25) for the ratio 30:2 and 4.5 (IQR 2.88) for the ratio 15:2 (P<0.001). The compression depth was 40.5mm (IQR 15.75) for 30:2 and 41mm (IQR 15.5) for 15:2 (P=0.5). The compression rate was 118beats/min (IQR 29) for 30:2 and 115beats/min (IQR 32) for 15:2 (P=0.02). The total number of compressions/5min was 347 (IQR 79) for 30:2 and 244compressions/5min (IQR 72.5) for 15:2 (P<0.001). The number of correct compression/5min was 61.5 (IQR 211.75) for 30:2 and 55.5 (IQR 142.75) for 15:2 (P=0.001). The relative risk (RR) of incomplete release in 30:2 versus 15:2 was 1.087 (95% CI=0.633-1.867). Although the 30:2 ratio is rated to be more exhausting, the 30:2 technique delivers more chest compressions and the quality of chest compressions remains unchanged.

  6. False-Positive Results after Environmental Pinworm PCR Testing due to Rhabditid Nematodes in Corncob Bedding

    PubMed Central

    Leblanc, Mathias; Berry, Kristina; Graciano, Sandy; Becker, Brandon; Reuter, Jon D

    2014-01-01

    Modern rodent colonies are housed in individually ventilated cages to protect the animals from contamination with adventitious pathogens. Standard health monitoring through soiled-bedding sentinels does not always detect infections, especially in the context of low pathogen prevalence. Recently proposed alternatives include analyzing environmental samples from the cages or rack exhaust by PCR to improve the detection of rodent pathogens but optimal sampling strategies have not yet been established for different microorganisms. Although generally very sensitive and specific, these molecular assays are not foolproof and subject to false-positive and –negative results and should always be interpreted cautiously with an overall understanding of the intrinsic controls and all the variables that may affect the results. Here, we report a limited Aspiculuris tetraptera outbreak in a mouse barrier facility that was detected by fecal PCR in sentinels and confirmed by fecal flotation and direct cecal examination of both sentinels and colony animals. The outbreak led to a widespread survey of all facilities for pinworms by using environmental PCR from ventilated rack exhaust plenums. Environmental PCR suggested an unexpected widespread contamination of all ventilated racks holding nonautoclaved cages, but results could not be confirmed in sentinel or colony animals by fecal flotation, cecal and colonic examination, or cage PCR testing. After additional investigation, the unexpected environmental PCR results were confirmed as false-positive findings due to the nonspecificity of the assay, leading to the amplification of rhabditid nematodes, which are not infectious in rodents but which contaminated the corncob bedding. PMID:25650980

  7. Evaluation of Passive Vents in New Construction Multifamily Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sean; Berger, David; Zuluaga, Marc

    Exhaust ventilation and corresponding outdoor air strategies are being implemented in high-performance new construction multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards. CARB's 2014 'Evaluation of Ventilation Strategies in New Construction Multifamily Buildings' consistently demonstrated that commonly used outdoor air strategies are not performing as expected. Of the four strategies evaluated in 2014, the exhaust ventilation system that relied on outdoor air from a pressurized corridor was ruled out as amore » potential best practice due to its conflict with meeting requirements within most fire codes. Outdoor air that is ducted directly to the apartments was a strategy determined to have the highest likelihood of success, but with higher first costs and operating costs. Outdoor air through space conditioning systems was also determined to have good performance potential, with proper design and execution. The fourth strategy, passive systems, was identified as the least expensive option for providing outdoor air directly to apartments, with respect to both first costs and operating costs. However, little is known about how they actually perform in real-world conditions or how to implement them effectively. Based on the lack of data available on the performance of these low-cost systems and their frequent use in the high-performance building programs that require a provision for outdoor air, this research project sought to further evaluate the performance of passive vents.« less

  8. Building America Case Study: Evaluation of Passive Vents in New-Construction Multifamily Buildings, New York, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Exhaust ventilation and corresponding outdoor air strategies are being implemented in high-performance new construction multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards. CARB's 2014 'Evaluation of Ventilation Strategies in New Construction Multifamily Buildings' consistently demonstrated that commonly used outdoor air strategies are not performing as expected. Of the four strategies evaluated in 2014, the exhaust ventilation system that relied on outdoor air from a pressurized corridor was ruled out as amore » potential best practice due to its conflict with meeting requirements within most fire codes. Outdoor air that is ducted directly to the apartments was a strategy determined to have the highest likelihood of success, but with higher first costs and operating costs. Outdoor air through space conditioning systems was also determined to have good performance potential, with proper design and execution. The fourth strategy, passive systems, was identified as the least expensive option for providing outdoor air directly to apartments, with respect to both first costs and operating costs. However, little is known about how they actually perform in real-world conditions or how to implement them effectively. Based on the lack of data available on the performance of these low-cost systems and their frequent use in the high-performance building programs that require a provision for outdoor air, this research project sought to further evaluate the performance of passive vents.« less

  9. 40 CFR 60.2730 - What monitoring equipment must I install and what parameters must I monitor?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... continuously operate a bag leak detection system as specified in paragraphs (b)(1) through (8) of this section. (1) You must install and operate a bag leak detection system for each exhaust stack of the fabric filter. (2) Each bag leak detection system must be installed, operated, calibrated, and maintained in a...

  10. Removal of odor using biofilter from duck confinement buildings.

    PubMed

    Lau, Anthony; Cheng, Kimberly

    2007-06-01

    The poultry and waterfowl industry in the Fraser Valley of British Columbia needs to deal with odor emission problems. The objective of this study is to evaluate the performance of a pilot-scale biofiltration system for treating odors from the exhaust air streams of a commercial duck farm building before their release to the atmosphere. A pilot-scale biofiltration system with semi-enclosed wooden structure was designed, constructed and installed to treat the exhaust air from one of the 12 operating ventilation exhaust fans, having a ventilation rate of 2.36 m3/s. The empty bed residence time of the biofilter was 5-10 seconds at the design flow rate. The biofilter media comprised of 2 parts softwood chips and barks to 1 part finished compost. Fabric filters were used for pre-treatment to protect the biofilter from clogging by dust particles and feathers. Odor reduction was determined by measuring the concentration of the air entering and leaving the biofilter via olfactometry analysis. The odor concentration of untreated barn air was found to vary from 8553+/-1006 to 12171+/-1575 OU/m3; however, the odor concentration was substantially reduced to 420+/-195 OU/m(3) after the manure storage was cleaned out at the end of summer. The odor removal efficiency of the biofilter system averaged 95+/-3%. The high frequency of cleaning and replacement required of the fabric filters would considerably increase the operating cost. Alternative methods of dust and odor removal that are more cost-effective will need to be investigated in the future.

  11. Optimization of Ventilation Energy Demands and Indoor Air Quality in High-Performance Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hun, Diana E; Jackson, Mark C; Shrestha, Som S

    2014-01-01

    High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. We attempted to bridge these two areas by conducting tests in a research house located in Oak Ridge, TN, that was 20 months old, energy-efficient (i.e., expected to consume 50% less energy than a house built per the 2006 IRC), tightly-built (i.e., natural ventilation rate ~0.02 h-1), unoccupied, and unfurnished. We identified air pollutants of concern in the test home that could generally serve as indicators of IAQ, and conduced field experiments and computer simulations to determine the effectiveness and energy required by various techniquesmore » that lessened the concentration of these contaminants. Formaldehyde was selected as the main pollutant of concern among the contaminants that were sampled in the initial survey because it was the only compound that showed concentrations that were greater than the recommended exposure levels. Field data indicate that concentrations were higher during the summer primarily because emissions from sources rise with increases in temperature. Furthermore, supply ventilation and gas-phase filtration were effective means to reduce formaldehyde concentrations; however, exhaust ventilation had minimal influence on this pollutant. Results from simulations suggest that formaldehyde concentrations obtained while ventilating per ASHRAE 62.2-2010 could be decreased by about 20% from May through September through three strategies: 1) increasing ASHRAE supply ventilation by a factor of two, 2) reducing the thermostat setpoint from 76 to 74 F, or 3) running a gas-phase filtration system while decreasing supply ventilation per ASHRAE by half. In the mixed-humid climate of Oak Ridge, these strategies caused increases in electricity cost of ~$5 to ~$15/month depending on outdoor conditions.« less

  12. Health-hazard evaluation report HETA 86-348-1756, J'Leen Ltd. , Boulder, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gunter, B.J.

    1986-12-01

    In response to a request from the owner of J'Leen, Ltd., Boulder, Colorado, an evaluation of exposures to lead in the copper and lead glazing art studio was carried out. Breathing-zone and general air samples were analyzed by NIOSH Method P and CAM 173, blood lead was measured by voltammetry, and free-erythrocyte protoporphyrin was measured photofluorometrically. Ventilation was found to be inadequate for removing airborne lead resulting from use of lead dust and furnaces. The author concludes that the high environmental lead levels present a health hazard, and recommends improved exhaust ventilation, continued use of ultrafilter respiratory protection, and educationmore » of new employees on clean work habits.« less

  13. Twenty years of experience in monitoring 41Ar in a research reactor and decrease of its discharge into the environment.

    PubMed

    Fukui, M

    2004-04-01

    The radioactive gas 41Ar has been produced at high concentration by neutron activation near the reactor core in the Kyoto University Research Reactor. A pipe line for an exhaust stream, so-called sweep gas, was fabricated at the construction of the reactor in 1964 in order to exhale 41Ar from the facilities above to the environment. Other exhaust lines with decay tanks were established separately from the sweep line for both the cold neutron source in 1986 and the heavy-water tank in 1996, respectively, because a higher amount of 41Ar was thought to be produced from these facilities due to the improvement. As a result, a slight change in the flow rate of the exhaust was found to have a great deal of influence on both the 41Ar concentration in the reactor room and the rate of emission from the stack. By monitoring the exhaust air from the decay tanks, the mechanism for decreasing the emission was clarified together with identifying an obstacle, i.e., the condensate against the steady state flow, formed in the exhaust pipe. By setting the flow rate suitably in the exhaust line, the rate of 41Ar emission from the biological shielding into both the work place in the reactor room and the environment has been controlled as low as reasonably achievable.

  14. PROCESS WATER BUILDING, TRA605. FLASH EVAPORATORS ARE PLACED ON UPPER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PROCESS WATER BUILDING, TRA-605. FLASH EVAPORATORS ARE PLACED ON UPPER LEVEL OF EAST SIDE OF BUILDING. WALLS WILL BE FORMED AROUND THEM. WORKING RESERVOIR BEYOND. CAMERA FACING EASTERLY. EXHAUST AIR STACK IS UNDER CONSTRUCTION AT RIGHT OF VIEW. INL NEGATIVE NO. 2579. Unknown Photographer, 6/18/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  15. A fuel cell balance of plant test facility

    NASA Astrophysics Data System (ADS)

    Dicks, A. L.; Martin, P. A.

    Much attention is focused in the fuel cell community on the development of reliable stack technology, but to successfully exploit fuel cells, they must form part of integrated power generation systems. No universal test facilities exist to evaluate SOFC stacks and comparatively little research has been undertaken concerning the issues of the rest of the system, or balance of plant (BOP). BG, in collaboration with Eniricerche, has therefore recently designed and built a test facility to evaluate different configurations of the BOP equipment for a 1-5 kWe solid oxide fuel cell (SOFC) stack. Within this BOP project, integrated, dynamic models have been developed. These have shown that three characteristic response times exist when the stack load is changed and that three independent control loops are required to manage the almost instantaneous change in power output from an SOFC stack, maintain the fuel utilisation and control the stack temperature. Control strategies and plant simplifications, arising from the dynamic modelling, have also been implemented in the BOP test facility. An SOFC simulator was designed and integrated into the control system of the test rig to behave as a real SOFC stack, allowing the development of control strategies without the need for a real stack. A novel combustor has been specifically designed, built and demonstrated to be capable of burning the low calorific anode exhaust gas from an SOFC using the oxygen depleted cathode stream. High temperature, low cost, shell and tube heat exchangers have been shown to be suitable for SOFC systems. Sealing of high temperature anode recirculation fans has, however, been shown to be a major issue and identified as a key area for further investigation.

  16. Cooperation of Horizontal Ground Heat Exchanger with the Ventilation Unit During Summer - Case Study

    NASA Astrophysics Data System (ADS)

    Romańska-Zapała, Anna; Furtak, Marcin; Dechnik, Mirosław

    2017-10-01

    Renewable energy sources are used in the modern energy-efficient buildings to improve their energy balance. One of them is used in the mechanical ventilation system ground air heat exchanger (earth-air heat exchanger - EAHX). This solution, right after heat recovery from exhaust air (recuperation), allows the reduction in the energy needed to obtain the desired temperature of supply air. The article presents the results of "in situ" measurements of pipe ground air heat exchanger cooperating with the air handling unit, supporting cooling the building in the summer season, in Polish climatic conditions. The laboratory consists of a ventilation unit intake - exhaust with rotor for which the source of fresh air is the air intake wall and two air intakes field cooperating with the tube with ground air heat exchangers. Selection of the source of fresh air is performed using sprocket with actuators. This system is part of the ventilation system of the Malopolska Laboratory of Energy-Efficient Building (MLBE) building of Cracow University of Technology. The measuring system are, among others, the sensors of parameters of air inlets and outlets of the heat exchanger channels EAHX and weather station that senses the local weather conditions. The measurement data are recorded and archived by the integrated process control system in the building of MLBE. During the study measurements of operating parameters of the ventilation unit cooperating with the selected source of fresh air were performed. Two cases of operation of the system: using EAHX heat exchanger and without it, were analyzed. Potentially the use of ground air heat exchanger in the mechanical ventilation system can reduce the energy demand for heating or cooling rooms by the pre-adjustment of the supply air temperature. Considering the results can be concluded that the continuous use of these exchangers is not optimal. This relationship is appropriate not only on an annual basis for the transitional periods (spring and autumn), but also in individual days in the potentially most favorable periods of work exchanger (summer and winter). Inappropriate operation of the heat exchanger, will lead to a temporary increase in energy consumption for the preparation of the desired air temperature, relative to the fresh air unit which is non-pretreated. For optimal energy system operation: exchanger EAHX - air handling unit, to preserve the most favourable parameters of inlet air to handling unit, there is a need to dynamically adjust the source of fresh air, depending on changing external conditions and the required outlet temperature of central unit (temperature of air forced to the rooms).

  17. Study on Self-start up of Polymer Electrolyte Fuel Cell Stack at Subzero Temperature

    NASA Astrophysics Data System (ADS)

    Shirato, Hiroyasu; Hoshina, Hideo; Yamakoshi, Yukiyasu; Tomita, Kazuhiko; Oka, Yoshiaki

    This paper aims to boot up polymer electrolyte fuel cells at subzero temperature without energy from outside and compass the conditions. Visualization tests of water drainage and voltage-current density characteristics provided the selection of a serpentine type as a channel of a fuel cell separator for cold region. The successful start-up of the cell at subzero temperature requires suitable current densities corresponding to the ambient temperature since the lower the temperature is, the lower the cell voltage soon after the start-up is. Suitable amount of exhausted energy is also necessary for the successful self start-up. Humidification using potassium acetate 30 mass% solution provides increased impedance of the cell and inhibits the water freezing owing to its dispersal to the electrode compared to no humidification. A stack laminated 25 sheets of the serpentine type separators enables stabilized power generation at normal temperature. The stack is also bootable with no energy from outside at 263K.

  18. Positive pressure ventilation in the management of acute and chronic cardiac failure: a systematic review and meta-analysis.

    PubMed

    Nadar, Sunil; Prasad, Neeraj; Taylor, Rod S; Lip, Gregory Y H

    2005-03-18

    Chronic heart failure (CHF) is a common condition and is associated with excess morbidity and mortality, in spite of the many advances in its treatment. Chronic stable heart failure is also associated with an increased incidence of sleep-related breathing disorders, such as central sleep apnoea (CSA) and Cheyne Stokes respiration (CSR). Continuous positive airways pressure (CPAP) has been shown to alleviate the symptoms of CHF, improve left ventricular function and oxygenation. To a certain extent, CPAP also abolishes sleep-related breathing disorders in patients with chronic heart failure. In patients with acute pulmonary oedema, the use of positive pressure ventilation improves cardiac haemodynamic indices, as well as symptoms and oxygenation, and is associated with a lower need for intubation. However, some studies have cast doubts about its safety and suggest a higher rate of myocardial infarction associated with its use. In our opinion, non-invasive positive pressure ventilation and CPAP offers an adjunctive mode of therapy in patients with acute pulmonary oedema and chronic heart failure, who may not be suitable for intubation and in those not responsive to conventional therapies. Non-invasive ventilation also helps to improve oxygenation in those patients with exhaustion and respiratory acidosis. Many trials are still ongoing and the results of these studies would throw more light on the present role of non-invasive ventilation in the management of CHF.

  19. Characterization of indoor aerosol temporal variations for the real-time management of indoor air quality

    NASA Astrophysics Data System (ADS)

    Ciuzas, Darius; Prasauskas, Tadas; Krugly, Edvinas; Sidaraviciute, Ruta; Jurelionis, Andrius; Seduikyte, Lina; Kauneliene, Violeta; Wierzbicka, Aneta; Martuzevicius, Dainius

    2015-10-01

    The study presents the characterization of dynamic patterns of indoor particulate matter (PM) during various pollution episodes for real-time IAQ management. The variation of PM concentrations was assessed for 20 indoor activities, including cooking related sources, other thermal sources, personal care and household products. The pollution episodes were modelled in full-scale test chamber representing a standard usual living room with the forced ventilation of 0.5 h-1. In most of the pollution episodes, the maximum concentration of particles in exhaust air was reached within a few minutes. The most rapid increase in particle concentration was during thermal source episodes such as candle, cigarette, incense stick burning and cooking related sources, while the slowest decay of concentrations was associated with sources, emitting ultrafine particle precursors, such as furniture polisher spraying, floor wet mopping with detergent etc. Placement of the particle sensors in the ventilation exhaust vs. in the centre of the ceiling yielded comparable results for both measured maximum concentrations and temporal variations, indicating that both locations were suitable for the placement of sensors for the management of IAQ. The obtained data provides information that may be utilized considering measurements of aerosol particles as indicators for the real-time management of IAQ.

  20. Preliminary site-survey report on Frit Bagging Operation at Chi-Vit Corporation, Urbana, Ohio, June 16, 1982

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooper, T.C.

    A visit was made to the Frit Bagging Operation at the Chi-Vit Corporation located at Urbana, Ohio for the purpose of examining methods used at this facility to control worker exposure to hazardous materials during the production of various frits. Frit was the basic material for porcelain enamel used in major appliance finishes. The three major raw materials used to produce frit were soda-ash, borax, and silica-flour. In the manufacturing area batching, mixing, smelting, and bagging take place. All new employees were given a preemployment physical. An annual hearing evaluation was performed for all workers. Ventilation was provided throughout themore » operation. Each weight bin in the batching area was equipped with exhaust ventilation. The frit was moved by a vibration conveyor between smelter and bagger and passed under three exhaust hoods to remove airborne dust during this last portion of this transfer. A small capture hood at the packer unit removed airborne dust generated as material falls from the slide gate to the packer spout. The disposal of the bags was carried out in a very satisfactory manner. The author concludes that the controls used provided an exemplary work environment. The author recommends that an in-depth survey be conducted at this site.« less

  1. Reanalysis of Diesel Engine Exhaust and Lung Cancer Mortality in the Diesel Exhaust in Miners Study Cohort Using Alternative Exposure Estimates and Radon Adjustment

    PubMed Central

    Chang, Ellen T; Lau, Edmund C; Van Landingham, Cynthia; Crump, Kenny S; McClellan, Roger O; Moolgavkar, Suresh H

    2018-01-01

    Abstract The Diesel Exhaust in Miners Study (DEMS) (United States, 1947–1997) reported positive associations between diesel engine exhaust exposure, estimated as respirable elemental carbon (REC), and lung cancer mortality. This reanalysis of the DEMS cohort used an alternative estimate of REC exposure incorporating historical data on diesel equipment, engine horsepower, ventilation rates, and declines in particulate matter emissions per horsepower. Associations with cumulative REC and average REC intensity using the alternative REC estimate and other exposure estimates were generally attenuated compared with original DEMS REC estimates. Most findings were statistically nonsignificant; control for radon exposure substantially weakened associations with the original and alternative REC estimates. No association with original or alternative REC estimates was detected among miners who worked exclusively underground. Positive associations were detected among limestone workers, whereas no association with REC or radon was found among workers in the other 7 mines. The differences in results based on alternative exposure estimates, control for radon, and stratification by worker location or mine type highlight areas of uncertainty in the DEMS data. PMID:29522073

  2. The Expansion of the Pulmonary Rib Cage during Breath Stacking Is Influenced by Age in Obese Women

    PubMed Central

    Barcelar, Jacqueline de Melo; Aliverti, Andrea; Rattes, Catarina; Ximenes, Maria Eduarda; Campos, Shirley Lima; Brandão, Daniella Cunha; Fregonezi, Guilherme; de Andrade, Armèle Dornelas

    2014-01-01

    Objective To analyze in obese women the acute effects of the breath stacking technique on thoraco-abdominal expansion. Design and Methods Nineteen obese women (BMI≥30 kg/m2) were evaluated by anthropometry, spirometry and maximal respiratory muscle pressures and successively analyzed by Opto-Electronic Plethysmography and a Wright respirometer during quiet breathing and breath stacking maneuvers and compared with a group of 15 normal-weighted healthy women. The acute effects of the maneuvers were assessed in terms of total and compartmental chest wall volumes at baseline, end of the breath stacking maneuver and after the maneuver. Obese subjects were successively classified into two groups, accordingly to the response during the maneuver, group 1 = prevalent rib cage or group 2 = abdominal expansion. Results Age was significantly lower in group 1 than group 2. When considering the two obese groups, FEV1 was lower and minute ventilation was higher only in group 2 compared to controls group. During breath stacking, inspiratory capacity was significant differences in obese subjects with a smaller expansion of the pulmonary rib cage and a greater expansion of the abdomen compared to controls and also between groups 1 and 2. A significant inverse linear relationship was found between age and inspiratory capacity of the pulmonary rib cage but not of the abdomen. Conclusions In obese women the maximal expansion of the rib cage and abdomen is influenced by age and breath stacking maneuver could be a possible therapy for preventing respiratory complications. PMID:25372469

  3. [Update on the respiratory management of patients with chronic neuromuscular disease].

    PubMed

    Priou, P; Trzepizur, W; Meslier, N; Gagnadoux, F

    2017-12-01

    Neuromuscular diseases include a wide range of conditions that may involve potentially life-threatening respiratory complications (infection, respiratory failure). For patients with neuromuscular diseases, clinical assessment of respiratory function and regular pulmonary function tests are needed to screen for nocturnal respiratory disorders, weakness of the diaphragm and potential restrictive disorders and/or chronic hypercapnic respiratory insufficiency, possibly with couch deficiency. MANAGEMENT OF NOCTURNAL RESPIRATORY DISORDERS AND CHRONIC RESPIRATORY FAILURE: Nocturnal respiratory assistance is an important phase of care for nocturnal respiratory disorders and chronic respiratory failure. This may involve continuous positive airway pressure, adaptative servo-ventilation or non-invasive ventilation with a facial or nasal mask. As needed, diurnal assistance may be proposed by mouthpiece ventilation. Should non-invasive ventilation prove insufficient, or if significant swallowing disorders or recurrent bronchial obstruction develop, or in case of prolonged intubation, tracheotomy may be required. In case of lower airway infection with ineffective cough, physical therapy, associated with air stacking, intermittent positive pressure breathing or mechanical in-exsufflation may be proposed. Care for swallowing disorders, nutritional counseling (cachexia, obesity), vaccinations and therapeutic education are integral elements of patient-centered management aiming to prevent the negative impact of infection and to manage respiratory failure of chronic neuromuscular disease. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. 44. VIEW LOOKING EAST, OF WESTINGHOUSELEBLANC JET CONDENSER LOCATED UNDER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. VIEW LOOKING EAST, OF WESTINGHOUSE-LEBLANC JET CONDENSER LOCATED UNDER TURBINE NUMBER 3. THE SPHERICAL HOUSING AT THE TOP RIGHT OF THE PHOTOGRAPH IS A RELIEF VALVE. IN THE EVENTS OF TURBINE OVERPRESSURE THE RELIEF VALVE OPENS AND VENTS EXCESSIVE STEAM PRESSURE TO AN EXHAUST STACK THUS BYPASSING THE CONDENSER. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  5. Flammability properties and radiant fraction of FRT wood plastic composites using mass loss calorimeter under HRR hood

    Treesearch

    Mark A. Dietenberger; Charles R. Boardman; Nicole Stark

    2017-01-01

    A special test arrangement was used to assess the flammability of 4 different wood plastic composites (WPC), most with fire retardants, all of which has a tendency to high smoke production leading to high radiant energy losses to the apparatus walls. The mass loss calorimeter (MLC) was modified to include a thermopile on the exhaust pipe stack to compensate for radiant...

  6. Hydronic rooftop cooling systems

    DOEpatents

    Bourne, Richard C [Davis, CA; Lee, Brian Eric [Monterey, CA; Berman, Mark J [Davis, CA

    2008-01-29

    A roof top cooling unit has an evaporative cooling section that includes at least one evaporative module that pre-cools ventilation air and water; a condenser; a water reservoir and pump that captures and re-circulates water within the evaporative modules; a fan that exhausts air from the building and the evaporative modules and systems that refill and drain the water reservoir. The cooling unit also has a refrigerant section that includes a compressor, an expansion device, evaporator and condenser heat exchangers, and connecting refrigerant piping. Supply air components include a blower, an air filter, a cooling and/or heating coil to condition air for supply to the building, and optional dampers that, in designs that supply less than 100% outdoor air to the building, control the mixture of return and ventilation air.

  7. Experimental investigation of airborne contaminant transport by a human wake moving in a ventilated aircraft cabin

    NASA Astrophysics Data System (ADS)

    Poussou, Stephane B.

    The air ventilation system in jetliners provides a comfortable and healthy environment for passengers. Unfortunately, the increase in global air traffic has amplified the risks presented by infectious aerosols or noxious material released during flight. Inside the cabin, air typically flows continuously from overhead outlets into sidewall exhausts in a circular pattern that minimizes secondary flow between adjacent seat rows. However, disturbances frequently introduced by individuals walking along an aisle may alter air distribution, and contribute to spreading of contaminants. Numerical simulation of these convoluted transient flow phenomena is difficult and complex, and experimental assessment of contaminant distribution in real cabins often impractical. A fundamental experimental study was undertaken to examine the transport phenomena, to validate computations and to improve air monitoring systems. A finite moving body was modeled in a 10:1 scale simplified aircraft cabin equipped with ventilation, at a Reynolds number (based on body diameter) of the order of 10,000. An experimental facility was designed and constructed to permit measurements of the ventilation and wake velocity fields using particle image velocimetry (PIV). Contaminant migration was imaged using the planar laser induced fluorescence (PLIF) technique. The effect of ventilation was estimated by comparison with a companion baseline study. Results indicate that the evolution of a downwash predominant behind finite bodies of small aspect ratio is profoundly perturbed by the ventilation flow. The reorganization of vortical structures in the near-wake leads to a shorter longitudinal recirculation region. Furthermore, mixing in the wake is modified and contaminant is observed to convect to higher vertical locations corresponding to seated passenger breathing level.

  8. Fuel-Cell Water Separator

    NASA Technical Reports Server (NTRS)

    Burke, Kenneth Alan; Fisher, Caleb; Newman, Paul

    2010-01-01

    The main product of a typical fuel cell is water, and many fuel-cell configurations use the flow of excess gases (i.e., gases not consumed by the reaction) to drive the resultant water out of the cell. This two-phase mixture then exits through an exhaust port where the two fluids must again be separated to prevent the fuel cell from flooding and to facilitate the reutilization of both fluids. The Glenn Research Center (GRC) has designed, built, and tested an innovative fuel-cell water separator that not only removes liquid water from a fuel cell s exhaust ports, but does so with no moving parts or other power-consuming components. Instead it employs the potential and kinetic energies already present in the moving exhaust flow. In addition, the geometry of the separator is explicitly intended to be integrated into a fuel-cell stack, providing a direct mate with the fuel cell s existing flow ports. The separator is also fully scalable, allowing it to accommodate a wide range of water removal requirements. Multiple separators can simply be "stacked" in series or parallel to adapt to the water production/removal rate. GRC s separator accomplishes the task of water removal by coupling a high aspect- ratio flow chamber with a highly hydrophilic, polyethersulfone membrane. The hydrophilic membrane readily absorbs and transports the liquid water away from the mixture while simultaneously resisting gas penetration. The expansive flow path maximizes the interaction of the water particles with the membrane while minimizing the overall gas flow restriction. In essence, each fluid takes its corresponding path of least resistance, and the two fluids are effectively separated. The GRC fuel-cell water separator has a broad range of applications, including commercial hydrogen-air fuel cells currently being considered for power generation in automobiles.

  9. Ventilation.

    PubMed

    Turner, W A; Bearg, D W; Brennan, T

    1995-01-01

    This chapter begins with an overview of the history of ventilation guidelines, which has led to the guidelines that are in effect today. Of particular interest is the most recent return in the past 5 years to ventilation rates that more closely reflect a mean or average of the range of guidelines that have existed over the past century. OSHA's and the EPA's recognition of the need to operate ventilation systems in buildings in an accountable manner is also of note. Of even more interest is the resurgence of the concept of minimum mixing and once-through ventilation air that has been pursued in parts of Northern Europe for the past 10 years, and in a school that is being designed with this concept in New Hampshire. In addition, the design concept of equipping office buildings with low pressure drop high efficiency particle filtration to remove fine particles from all of the air that is supplied to the occupants is being used increasingly in the U.S. This chapter also presents an overview of the various types of ventilation systems found in homes and commercial office buildings and the common indoor air quality problems that may be associated with them. It also offers an overview of common HVAC evaluation techniques that can be used to determine if a ventilation system is performing in a manner that makes sense for the use of the space and the needs of the occupants. Are the occupants receiving a reasonable supply of outdoor air? Is the air that they receive of reasonable quality? Are obvious pollutants being exhausted? Ventilation systems have become extremely complex and more difficult to run and maintain over the past 40 years. This trend will continue to drive the need for professionally maintained HVAC equipment that is serviced and run by individuals who are accountable for the quality of the air that the system delivers.

  10. Walk-through survey report: Control technology for metal reclamation industries at Exide/General Battery Corporation, Reading, Pennsylvania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, R.M.

    1994-03-30

    A walk through survey was made at Exide/General Battery Corporation, Reading, Pennsylvania to identify and evaluate control methods to reduce lead exposure. About 20,000 to 25,000 batteries a day were recycled, primarily automobile batteries. Lead and plastic from the batteries were reclaimed. The company used local exhaust ventilation, enclosed ventilated booths, partial enclosures, and automated operations throughout production areas of the site. Various occupational safety and health programs were in place including occupational and safety training, a respiratory protection program, various hygiene programs, and blood lead monitoring programs. These findings will be compared with those from other sites and themore » facility with the lowest lead exposure levels will be examined carefully so that others may be brought in line with the best of standards.« less

  11. Health-hazard evaluation determination report No. 75-181-287, Fibreboard Corporation, Stockton, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okawa, M.T.

    1976-05-01

    Employees in the Litho Department of the Fibreboard Corporation Plant in Stockton, California are not found to be exposed to toxic concentrations of dusting powders, but are exposed to airborne dust levels from the powders which exceed the State of California OSHA standard and the threshold limits for nuisance dust. Safety recommendations include servicing of exhaust ventilation systems regularly, vacuum cleaning instead of dry sweeping, and making NIOSH Certified Respirators available whenever needed.

  12. Pulsed Heterodyne CO2 Laser/Scanner System. Volume 1. Assembly Report.

    DTIC Science & Technology

    1983-06-01

    rack #2 houses the switches and variacs controlling the DC power rectifier, which is in an oil tank under the optical bench. These two units are...or fire hazards (due to oil filled electrical equipments). This section, however, addresses only the four main hazards. Ozone The atmospheric pressure...ventilation of the exhaust of the 002 lasers is essencial to the safe operation of this system. High Voltage The system consists of 40 separate

  13. Application of local exhaust ventilation system and integrated collectors for control of air pollutants in mining company.

    PubMed

    Ghorbani Shahna, Farshid; Bahrami, Abdulrahman; Farasati, Farhad

    2012-01-01

    Local exhaust ventilation (LEV) systems and integrated collectors were designed and implemented in a mining company in order to control emitted air pollutant from furnaces. The LEV was designed for capture and transition of air pollutants emitted from furnaces to the integrated collectors. The integrated collectors including four high efficiency Stairmand model cyclones for control of particulate matter, a venturi scrubber for control of the fine particles, SO(2) and a part of H(2)S to follow them, and a packed scrubber for treatment of the residual H(2)S and SO(2) were designed. Pollutants concentration were measured to determine system effectiveness. The results showed that the effectiveness of LEV for reducing workplace pollution is 91.83%, 96.32% and 83.67% for dust, SO(2) and H(2)S, respectively. Average removal efficiency of particles by combination of cyclone and venturi scrubber was 98.72%. Average removal efficiency of SO(2) and H(2)S were 95.85% and 47.13% for the venturi scrubber and 68.45% and 92.7% for the packed bed scrubber. The average removal efficiency of SO(2) and H(2)S were increased to 99.1% and 95.95% by the combination of venturi and packed bed scrubbers. According to the results, integrated collectors are a good air pollution control option for industries with economic constraints and ancient technologies.

  14. A novel approach to scavenging anesthetic gases in rodent surgery.

    PubMed

    Nesbitt, Jeffrey C; Krageschmidt, Dale A; Blanco, Michael C

    2013-01-01

    Laboratory animal procedures using gas anesthetics may amass elevated waste gas concentrations in operating rooms if controls are not implemented for capturing and removing the vapors. Area sampling using an infrared analyzer indicated isoflurane concentrations likely to exceed occupational exposure guidelines. Our study showed environmental concentrations of oxygen as high as 40% and isoflurane concentrations >100 ppm when no controls or merely passive controls were utilized. These extraneous isoflurane emissions were determined to be originating from the pre-procedural induction process as well as the gas delivery nose cone. A novel waste gas collection cylinder was designed to enclose the gas delivery nose cone and animal head during the administration of anesthetic gases. The vented cylinder utilized a house vacuum to remove the waste anesthetic gases from the surgical field. A commercially available induction chamber designed to be actively and externally exhausted was used to lower concentrations during the induction process. With implementation of local exhaust ventilation controls, waste anesthetic gas concentrations decreased to below recommended occupational exposure levels. In vitro (sham) testing compared favorably to in vivo measurements validating the reduction capability of active ventilation during rodent anesthetic administration. In vivo isoflurane reductions for the induction chamber emissions, the operating room, and the surgeon's breathing zone were 95%, 60%, and 53%, respectively. The same measurements for an in vitro procedure were 98%, 84%, and 87%, respectively.

  15. Cold start dynamics and temperature sliding observer design of an automotive SOFC APU

    NASA Astrophysics Data System (ADS)

    Lin, Po-Hsu; Hong, Che-Wun

    This paper presents a dynamic model for studying the cold start dynamics and observer design of an auxiliary power unit (APU) for automotive applications. The APU is embedded with a solid oxide fuel cell (SOFC) stack which is a quiet and pollutant-free electric generator; however, it suffers from slow start problem from ambient conditions. The SOFC APU system equips with an after-burner to accelerate the start-up transient in this research. The combustion chamber burns the residual fuel (and air) left from the SOFC to raise the exhaust temperature to preheat the SOFC stack through an energy recovery unit. Since thermal effect is the dominant factor that influences the SOFC transient and steady performance, a nonlinear real-time sliding observer for stack temperature was implemented into the system dynamics to monitor the temperature variation for future controller design. The simulation results show that a 100 W APU system in this research takes about 2 min (in theory) for start-up without considering the thermal limitation of the cell fracture.

  16. Evaluation of continuous air monitor placement in a plutonium facility.

    PubMed

    Whicker, J J; Rodgers, J C; Fairchild, C I; Scripsick, R C; Lopez, R C

    1997-05-01

    Department of Energy appraisers found continuous air monitors at Department of Energy plutonium facilities alarmed less than 30% of the time when integrated room plutonium air concentrations exceeded 500 DAC-hours. Without other interventions, this alarm percentage suggests the possibility that workers could be exposed to high airborne concentrations without continuous air monitor alarms. Past research has shown that placement of continuous air monitors is a critical component in rapid and reliable detection of airborne releases. At Los Alamos National Laboratory and many other Department of Energy plutonium facilities, continuous air monitors have been primarily placed at ventilation exhaust points. The purpose of this study was to evaluate and compare the effectiveness of exhaust register placement of workplace continuous air monitors with other sampling locations. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories at Los Alamos National Laboratory. An array of laser particle counters positioned in the rooms measured time-resolved aerosol dispersion. Results showed alternative placement of air samplers generally resulted in aerosol detection that was faster, often more sensitive, and equally reliable compared with samplers at exhaust registers.

  17. Breath-stacking and incentive spirometry in Parkinson's disease: Randomized crossover clinical trial.

    PubMed

    Ribeiro, Rhayssa; Brandão, Daniella; Noronha, Jéssica; Lima, Cibelle; Fregonezi, Guilherme; Resqueti, Vanessa; Dornelas de Andrade, Arméle

    2018-05-01

    Patients with Parkinson's disease often exhibit respiratory disorders and there are no Respiratory Therapy protocols which are suggested as interventions in Parkinson's patients. The aim of this study is to evaluate the effects of Breathing-Stacking (BS) and incentive spirometer (IS) techniques in volume variations of the chest wall in patients with Parkinson's Disease (PD). 14 patients with mild-moderate PD were included in this randomized cross-over study. Volume variations of the chest wall were assessed before, immediately after, then 15 and 30 min after BS and IS performance by optoelectronic plethysmography. Tidal volume (VT) and minute ventilation (MV) significantly increased after BS and IS techniques (p < 0.05). There was greater involvement of pulmonary and abdominal compartments after IS. The results suggest that these re-expansion techniques can be performed to immediately improve volume. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Benthic δ13C stacks: Metrics for deglacial changes in deep ocean carbon storage and the terrestrial biosphere

    NASA Astrophysics Data System (ADS)

    Peterson, C.; Lisiecki, L. E.

    2016-12-01

    Across the deglaciation, atmospheric CO2 and global temperatures rise while the deep ocean ventilates carbon to the atmosphere and terrestrial biosphere. As the terrestrial biosphere expands, the mean global ocean δ13C signature increases in response. How well constrained is the global mean benthic δ13C from 20-6 ka? Are the atmosphere and terrestrial biosphere signals in benthic δ13C coupled across the deglaciation? Improved understanding of deglacial carbon cycle interactions can help close the gap between data-based and model-based estimates of global mean benthic δ13C and deep ocean carbon storage changes. Here we present a 118-record compilation of Cibicides wuellerstorfi δ13C time series that span 20-6 kyr. The δ13C records with a resolution better than 3 kyr and gaps between data smaller than 4 kyr are aligned to age models that are constrained by planktic 14C ages (Stern and Lisiecki, 2014). The δ13C records are stacked within nine regions. Then these regional stacks are combined using volume-weighted averages to create intermediate, deep and whole ocean δ13C stacks. The δ13C gradient between the intermediate and deep stacks covaries with atmospheric CO2 change. Meanwhile the deglacial global ocean mean δ13C rise tracks the expansion of the global terrestrial biosphere from 19-6 ka. From this volume-weighted global δ13C stack, the LGM-Holocene mean δ13C change is 0.35±0.10‰ similar to previous estimates (Curry et al., 1988; Duplessy et al., 1988; Peterson et al., 2015; Gebbie et al., 2015). The δ13C stacks and this 4D δ13C compilation are ideal for model-data comparisons and time-stepping 3D visualizations.

  19. Heat exhaustion in a deep underground metalliferous mine

    PubMed Central

    Donoghue, A; Sinclair, M.; Bates, G.

    2000-01-01

    OBJECTIVES—To examine the incidence, clinical state, personal risk factors, haematology, and biochemistry of heat exhaustion occurring at a deep underground metalliferous mine. To describe the underground thermal conditions associated with the occurrence of heat exhaustion.
METHODS—A 1 year prospective case series of acute heat exhaustion was undertaken. A history was obtained with a structured questionnaire. Pulse rate, blood pressure, tympanic temperature, and specific gravity of urine were measured before treatment. Venous blood was analysed for haematological and biochemical variables, during the acute presentation and after recovery. Body mass index (BMI) and maximum O2 consumption (V̇O2 max) were measured after recovery. Psychrometric wet bulb temperature, dry bulb temperature, and air velocity were measured at the underground sites where heat exhaustion had occurred. Air cooling power and psychrometric wet bulb globe temperature were derived from these data.
RESULTS—106 Cases were studied. The incidence of heat exhaustion during the year was 43.0 cases / million man-hours. In February it was 147 cases / million man-hours. The incidence rate ratio for mines operating below 1200 m compared with those operating above 1200 m was 3.17. Mean estimated fluid intake was 0.64 l/h (SD 0.29, range 0.08-1.50). The following data were increased in acute presentation compared with recovery (p value, % of acute cases above the normal clinical range): neutrophils (p<0.001, 36%), anion gap (p<0.001, 63%), urea (p<0.001, 21%), creatinine (p<0.001, 30%), glucose (p<0.001, 15%), serum osmolality (p=0.030, 71%), creatine kinase (p=0.002, 45%), aspartate transaminase (p<0.001, 14%), lactate dehydrogenase (p<0.001, 9.5%), and ferritin (p<0.001, 26%). The following data were depressed in acute presentation compared with recovery (p value, % of acute cases below the normal clinical range): eosinophils (p=0.003, 38%) and bicarbonate (p=0.011, 32%). Urea and creatinine were significantly increased in miners with heat cramps compared with miners without this symptom (p<0.001), but there was no significant difference in sodium concentration (p=0.384). Mean psychrometric wet bulb temperature was 29.0°C (SD 2.2, range 21.0-34.0). Mean dry bulb temperature was 37.4°C (SD 2.4, range 31.0-43.0). Mean air velocity was 0.54 m/s (SD 0.57, range 0.00-4.00). Mean air cooling power was 148 W/m2 (SD 49, range 33-290) Mean psychrometric wet bulb globe temperature was 31.5°C (SD 2.0, range 25.2-35.3). Few cases (<5%) occurred at psychrometric wet bulb temperature <25.0°C, dry bulb temperature <33.8°C, air velocity >1.56 m/s, air cooling power >248 W/m2, or psychrometric wet bulb globe temperature <28.5°C.
CONCLUSION—Heat exhaustion in underground miners is associated with dehydration, neutrophil leukocytosis, eosinopenia, metabolic acidosis, increased glucose and ferritin, and a mild rise in creatine kinase, aspartate transaminase, and lactate dehydrogenase. Heat cramps are associated with dehydration but not hyponatraemia. The incidence of heat exhaustion increases during summer and at depth. An increased fluid intake is required. Heat exhaustion would be unlikely to occur if ventilation and refrigeration achieved air cooling power >250 W/m2 at all underground work sites.


Keywords: heat; mining; ventilation PMID:10810098

  20. Effects of post-capture ventilation assistance and elevated water temperature on sockeye salmon in a simulated capture-and-release experiment

    PubMed Central

    Robinson, Kendra A.; Hinch, Scott G.; Gale, Marika K.; Clark, Timothy D.; Wilson, Samantha M.; Donaldson, Michael R.; Farrell, Anthony P.; Cooke, Steven J.; Patterson, David A.

    2013-01-01

    The live release of wild adult Pacific salmon (Oncorhynchus spp.) following capture is a management tactic often used in commercial, aboriginal, and recreational fisheries. Fisheries capture and handling can be both exhausting and stressful to fish, which can limit their ability to swim and survive after release. As a result, researchers have assessed methods intended to improve post-release survival by assisting the flow of water over the gills of fish prior to release. Such approaches use recovery bags or boxes that direct water over the gills of restrained fish. This study evaluated a method of assisting ventilation that mimics one often employed by recreational anglers (i.e. holding fish facing into a current). Under laboratory conditions, wild Fraser River sockeye salmon (Oncorhynchus nerka) either received manual ventilation assistance for 1 min using a jet of water focused at the mouth or were left to recover unassisted following a capture-and-release simulation. A control group consisted of fish that were not exposed to the simulation or ventilation assistance. The experiment was conducted at 16 and 21°C, average and peak summer water temperatures for the Fraser River, and fish survival was monitored for 33 days. At 21°C, all fish perished within 3 days after treatment in all experimental groups, highlighting the consequences of handling adult sockeye salmon during elevated migration temperatures. Survival was higher at 16°C, with fish surviving on average 15–20 days after treatment. At 16°C, the capture-and-release simulation and ventilation assistance did not affect the survival of males; however, female survival was poor after the ventilation assistance compared with the unassisted and control groups. Our results suggest that the method of ventilation assistance tested in this study may not enhance the post-release survival of adult Fraser River sockeye salmon migrating in fresh water. PMID:27293599

  1. Integrated science building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conklin, Shane

    2013-09-30

    Shell space fit out included faculty office advising space, student study space, staff restroom and lobby cafe. Electrical, HVAC and fire alarm installations and upgrades to existing systems were required to support the newly configured spaces. These installations and upgrades included audio/visual equipment, additional electrical outlets and connections to emergency generators. The project provided increased chilled water capacity with the addition of an electric centrifugal chiller. Upgrades associated with chiller included upgrade of exhaust ventilation fan, electrical conductor and breaker upgrades, piping and upgrades to air handling equipment.

  2. Reducing Work Content in Early Stage Naval Ship Designs (Briefing Charts)

    DTIC Science & Technology

    2014-05-14

    criticizes US naval ships for: • early design decisions that lock in density • poor arrangements of piping and ventilation 8 An overly dense ship with...Thresholds Update Save As Exit T45 #1 T45 #2 T45 #3 HPC Enables Exhaustive Exploration by: and Visualization Exploring The Space Evaluating The Space From...design points such as traditional design spiral method 30 SHIP AVG Weighted Qty (Qty) by Cost 1980s Reagan Build-up 14 10% 1% 1990/2000s Low Rate

  3. Radon measurements in the Gran Sasso Underground Laboratory.

    PubMed

    Arpesella, C; Bam, B B; Bassignani, A; Cecchini, S; Colombo, G; Dekhissi, H; Fresca Fantoni, R; Giacomelli, G; Lembo, L; Maltoni, G; Mandrioli, G; Patrizii, L; Sartorio, C; Serra, P; Togo, V; Vilela, E

    1997-04-01

    Systematic radon monitoring in the Gran Sasso Underground Laboratory was performed in order to determine the background radon contribution to the sophisticated experimental apparatus and to check health physics standards for the personnel. As expected, the radon concentrations were found to depend strongly on the ventilation in the three experimental halls. Considerable reductions in the radon concentrations were obtained in 1993, when fresh air was drawn into the laboratory through a pipe and exhaust air was routed into the highway tunnel.

  4. Causes Of Low Efficiency Of Combined Ventilation System In Coal Mines In Resolving The Problem Of Air Leaks (Inflows) Between Levels And Surface

    NASA Astrophysics Data System (ADS)

    Popov, Valeriy; Filatov, Yuriy; Lee, Hee; Golik, Anatoliy

    2017-11-01

    The paper discusses the problem of the underground mining safety control. The long-term air intake to coal accumulations is reviewed as one of the reasons of endogenous fires during mining. The methods of combating air leaks (inflows) in order to prevent endogenous fires are analyzed. The calculations showing the discrepancy between the design calculations for the mine ventilation, disregarding a number of mining-andgeological and mining-engineering factors, and the actual conditions of mining are given. It is proved that the conversion of operating mines to combined (pressure and exhaust) ventilation system in order to reduce the endogenous fire hazard of underground mining is unreasonable due to impossibility of providing an optimal distribution of aerodynamic pressure in mines. The conversion does not exclude the entry of air into potentially hazardous zones of endogenous fires. The essence of the combined application of positive and negative control methods for the distribution of air pressure is revealed. It consists of air doors installation in easily ventilated airways and installation of pressure equalization chambers equipped with auxiliary fans near the stoppings, working sections and in parallel airways.The effectiveness of the combined application of negative and positive control methods for the air pressure distribution in order to reduce endogenous fire hazard of mining operations is proved.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, M.; Lee, S.C.

    The indoor and outdoor levels of VOCs and PM{sub 2.5} were measured at two classrooms of two schools; one is naturally ventilated, while the other had two window type air-conditioners and four exhaust fans. The ventilation rates at the two classrooms were 0.937 ACH (Classroom A) and 0.217 ACH (Classroom B). Both classrooms had ventilation requirements below the ASHRAE Standard 62-1989 assuming that the outdoor contaminant levels were within the ASHRAE requirements. The abundance and concentration of volatile organic species found indoors and outdoors of Classroom B were higher than Classroom A since Classroom B is located in a heavilymore » trafficked area. The classroom without air-conditioner (A) had higher I/O ratios than Classroom B due to the higher ventilation rates. The air-conditioner, though not providing enough fresh air to the classroom, might act as a barrier for outdoor pollutants. The reduction of PM2.5 levels Classroom A was 30% and at Classroom B was 67%. The air-conditioning system in Classroom B could be removing some of the fine particulate matter from the outdoor supply air before entering the classroom. The use of air-conditioners can keep outdoor pollutants from entering the classroom, but could increase the level of indoor produced pollutant. From this study, air-conditioning systems in classroom somehow prevent pollutants from entering, and besides used to lowering environmental noise should be encouraged at schools located in heavily polluted environments.« less

  6. A comparison between tracer gas and aerosol particles distribution indoors: The impact of ventilation rate, interaction of airflows, and presence of objects.

    PubMed

    Bivolarova, M; Ondráček, J; Melikov, A; Ždímal, V

    2017-11-01

    The study investigated the separate and combined effects of ventilation rate, free convection flow produced by a thermal manikin, and the presence of objects on the distribution of tracer gas and particles in indoor air. The concentration of aerosol particles and tracer gas was measured in a test room with mixing ventilation. Three layouts were arranged: an empty room, an office room with an occupant sitting in front of a table, and a single-bed hospital room. The room occupant was simulated by a thermal manikin. Monodisperse particles of three sizes (0.07, 0.7, and 3.5 μm) and nitrous oxide tracer gas were generated simultaneously at the same location in the room. The particles and gas concentrations were measured in the bulk room air, in the breathing zone of the manikin, and in the exhaust air. Within the breathing zone of the sitting occupant, the tracer gas emerged as reliable predictor for the exposure to all different-sized test particles. A change in the ventilation rate did not affect the difference in concentration distribution between tracer gas and larger particle sizes. Increasing the room surface area did not influence the similarity in the dispersion of the aerosol particles and the tracer gas. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Air Leakage and Air Transfer Between Garage and Living Space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressuremore » relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.« less

  8. Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-11-01

    In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-housemore » air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.« less

  9. Building America Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-11-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressuremore » relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.« less

  10. Risk factors for work-related symptoms in northern California office workers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendell, M.J.

    1991-10-01

    In most episodes of health complaints reported in office buildings in the last-twenty years, causal factors have not been identified. In order to assess risk factors for work-related symptoms in office workers, a reanalysis was performed of previous studies, and an epidemiologic study was conducted. The reanalysis of data, showed remarkable agreement among studies. Air-conditioned buildings were consistently associated with higher prevalence of headache, lethargy, and eye, nose, or throat problems. Humidification was not a necessary factor for this higher prevalence. Mechanical ventilation without air-conditioning was not associated with higher symptom prevalence. A study was conducted among 880 office workers,more » within 12 office buildings selected without regard to worker complaints, in northern California. A number of factors were found associated with prevalence of work-related symptoms, after adjustment in a logistic regression model for personal, psychosocial, job, workspace, and building factors. Two different ventilation types were associated with increases Ln symptom prevalence, relative to workers in naturally ventilated buildings: mechanical supply and exhaust ventilation, without air conditioning and with operable windows; and air-conditioning with sealed windows. No study buildings were humidified. In both these ventilation types, the highest odds ratios (ORs) found were for skin symptoms (ORs-5.0, 5.6) and for tight chest or difficulty breathing (ORs-3.6, 4.3). Use of carbonless copies or photocopiers, sharing a workspace, carpets, new carpets, new walls, and distance from a window were associated with symptom increases. Cloth partitions and new paint were associated with symptom decreases.« less

  11. WASTE HANDLING BUILDING VENTILATION SYSTEM DESCRIPTION DOCUMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    P.A. Kumar

    2000-06-21

    The Waste Handling Building Ventilation System provides heating, ventilation, and air conditioning (HVAC) for the contaminated, potentially contaminated, and uncontaminated areas of the Monitored Geologic Repository's (MGR) Waste Handling Building (WHB). In the uncontaminated areas, the non-confinement area ventilation system maintains the proper environmental conditions for equipment operation and personnel comfort. In the contaminated and potentially contaminated areas, in addition to maintaining the proper environmental conditions for equipment operation and personnel comfort, the contamination confinement area ventilation system directs potentially contaminated air away from personnel in the WHB and confines the contamination within high-efficiency particulate air (HEPA) filtration units. Themore » contamination confinement areas ventilation system creates airflow paths and pressure zones to minimize the potential for spreading contamination within the building. The contamination confinement ventilation system also protects the environment and the public by limiting airborne releases of radioactive or other hazardous contaminants from the WHB. The Waste Handling Building Ventilation System is designed to perform its safety functions under accident conditions and other Design Basis Events (DBEs) (such as earthquakes, tornadoes, fires, and loss of the primary electric power). Additional system design features (such as compartmentalization with independent subsystems) limit the potential for cross-contamination within the WHB. The system provides status of important system parameters and equipment operation, and provides audible and/or visual indication of off-normal conditions and equipment failures. The Waste Handling Building Ventilation System confines the radioactive and hazardous material within the building such that the release rates comply with regulatory limits. The system design, operations, and maintenance activities incorporate ALARA (as low as is reasonably achievable) principles to maintain personnel radiation doses to all occupational workers below regulatory limits and as low as is reasonably achievable. The Waste Handling Building Ventilation System interfaces with the Waste Handling Building System by being located within the WHB and by maintaining specific pressures, temperatures, and humidity within the building. The system also depends on the WHB for water supply. The system interfaces with the Site Radiological Monitoring System for continuous monitoring of the exhaust air; the Waste Handling Building Fire Protection System for detection of fire and smoke; the Waste Handling Building Electrical System for normal, emergency, and standby power; and the Monitored Geologic Repository Operations Monitoring and Control System for monitoring and control of the system.« less

  12. Seismic analyses of equipment in 2736-Z complex. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ocoma, E.C.

    1995-04-01

    This report documents the structural qualification for the existing equipment when subjected to seismic loading in the Plutonium Storage Complex. It replaces in entirety Revision 0 and reconciles the U.S. Department of Energy (DOE) comments on Revision 0. The Complex consists of 2736-Z Building (plutonium storage vault), 2736-ZA Building (vault ventilation equipment building), and 2736-ZB Building (shipping/receiving, repackaging activities). The existing equipment structurally qualified in this report are the metal storage racks for 7 inch and lard cans in room 2 of Building 2736-Z; the cubicles, can holders and pedestals in rooms 1, 3, and 4 of Building 2736-Z; themore » ventilation duct including exhaust fans/motors, emergency diesel generator, and HEPA filter housing in Building 2736-ZA; the repackaging glovebox in Building 2736-ZB; and the interface duct between Buildings 2736-Z and 2736-ZA.« less

  13. Murine norovirus detection in the exhaust air of IVCs is more sensitive than serological analysis of soiled bedding sentinels.

    PubMed

    Zorn, Julia; Ritter, Bärbel; Miller, Manuel; Kraus, Monika; Northrup, Emily; Brielmeier, Markus

    2017-06-01

    One limitation to housing rodents in individually ventilated cages (IVCs) is the ineffectiveness of traditional health monitoring programs that test soiled bedding sentinels every quarter. Aerogen transmission does not occur with this method. Moreover, the transmission of numerous pathogens in bedding is uncertain, and sentinel susceptibility to various pathogens varies. A novel method using particle collection from samples of exhaust air was developed in this study which was also systematically compared with routine health monitoring using soiled bedding sentinels. We used our method to screen these samples for the presence of murine norovirus (MNV), a mouse pathogen highly prevalent in laboratory animal facilities. Exhaust air particles from prefilters of IVC racks with known MNV prevalence were tested by quantitative reverse transcription polymerase chain reaction (RT-qPCR). MNV was detected in exhaust air as early as one week with one MNV-positive cage per rack, while sentinels discharged MNV RNA without seroconverting. MNV was reliably and repeatedly detected in particles collected from samples of exhaust air in all seven of the three-month sampling rounds, with increasing MNV prevalence, while sentinels only seroconverted in one round. Under field conditions, routine soiled bedding sentinel health monitoring in our animal facility failed to identify 67% ( n = 85) of positive samples by RT-qPCR of exhaust air particles. Thus, this method proved to be highly sensitive and superior to soiled bedding sentinels in the reliable detection of MNV. These results represent a major breakthrough in hygiene monitoring of rodent IVC systems and contribute to the 3R principles by reducing the number of animals used and by improving experimental conditions.

  14. Assessment of need for transport tubes when continuously monitoring for radioactive aerosols.

    PubMed

    Whicker, J J; Rodgers, J C; Lopez, R C

    1999-09-01

    Aerosol transport tubes are often used to draw aerosol from desirable sampling locations to nearby air sampling equipment that cannot be placed at that location. In many plutonium laboratories at Los Alamos National Laboratory, aerosol transport tubes are used to transport aerosol from the front of room ventilation exhaust registers to continuous air monitors (CAMs) that are mounted on nearby walls. Transport tubes are used because past guidance suggests that extraction of aerosol samples from exhaust locations provides the most sensitive and reliable detection under conditions where the rooms have unpredictable release locations and significant spatial variability in aerosol concentrations after releases, and where CAMs cannot be located in front of exhaust registers without blocking worker walkways. Despite designs to minimize particle loss in tubes, aerosol transport model predictions suggest losses occur lowering the sensitivity of CAMs to accidentally released plutonium aerosol. The goal of this study was to test the hypotheses that the reliability, speed, and sensitivity of aerosol detection would be equal whether the sample was extracted from the front of the exhaust register or from the wall location of CAMs. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories to simulate plutonium aerosol releases. Networked laser particle counters (LPCs) were positioned to simultaneously measure time-resolved aerosol concentrations at each exhaust register (representative of sampling with transport tubes) and at each wall-mounted CAM location (representative of sampling without transport tubes). Results showed no significant differences in detection reliability, speed, or sensitivity for LPCs positioned at exhaust locations when compared to LPCs positioned at the CAM wall location. Therefore, elimination of transport tubes would likely improve CAM performance.

  15. EVALUATION OF ENGINEERING CONTROLS FOR THE MIXING OF FLAVORINGS CONTAINING DIACETYL AND OTHER VOLATILE INGREDIENTS

    PubMed Central

    Hirst, Deborah V.L.; Dunn, Kevin H.; Shulman, Stanley A.; Hammond, Duane R.; Sestito, Nicholas

    2015-01-01

    Exposures to diacetyl, a primary ingredient of butter flavoring, have been shown to cause respiratory disease among workers who mix flavorings. This study focused on evaluating ventilation controls designed to reduce emissions from the flavor mixing tanks, the major source of diacetyl in the plants. Five exhaust hood configurations were evaluated in the laboratory: standard hinged lid-opened, standard hinged lid-closed, hinged lid-slotted, dome with 38-mm gap, and dome with 114-mm gap. Tracer gas tests were performed to evaluate quantitative capture efficiency for each hood. A perforated copper coil was used to simulate an area source within the 1.2-meter diameter mixing tank. Capture efficiencies were measured at four hood exhaust flow rates (2.83, 5.66, 11.3, and 17.0 cubic meters per minute) and three cross draft velocities (0, 30, and 60 meters per minute). All hoods evaluated performed well with capture efficiencies above 90% for most combinations of exhaust volume and cross drafts. The standard hinged lid was the least expensive to manufacture and had the best average capture efficiency (over 99%) in the closed configuration for all exhaust flow rates and cross drafts. The hinged lid-slotted hood had some of the lowest capture efficiencies at the low exhaust flow rates compared to the other hood designs. The standard hinged lid performed well, even in the open position, and it provided a flexible approach to controlling emissions from mixing tanks. The dome hood gave results comparable to the standard hinged lid but it is more expensive to manufacture. The results of the study indicate that emissions from mixing tanks used in the production of flavorings can be controlled using simple inexpensive exhaust hoods. PMID:24649880

  16. LOFT. Mobile test building (TAN624) is recycled from ANP program ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LOFT. Mobile test building (TAN-624) is recycled from ANP program for placement before LOFT containment building door. It has not yet been connected to containment building. Note borated water tank at right of dome. Narrow, vertical structure at right of door is shroud is shroud for air exhaust duct. Filter vaults lie between duct shroud and stack. Camera facing westerly. Date: 1974. INEEL negative no. 74-1072 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  17. Removal of Pre-Formed Asbestos Insulation. A Project of the Manufacturing Technology Program.

    DTIC Science & Technology

    1982-10-01

    of Generator No. 5 4-18 21 Insulation on Exhaust Stack of Generator No. 6 4-19 22 Insulation on Overhead Pipe 4-19 23 Glasswool Insulation Construction...material insulation was glasswool . Since the glasswool does not have the capacity to absorb as much solution as asbestos insulation, the excess amount... glasswool (which was not suspected). Ran- dom core sampling undertaken earlier in the year had not revealed the presence of any glasswool . Pre-test core

  18. Tone Noise Predictions for a Spacecraft Cabin Ventilation Fan Ingesting Distorted Inflow and the Challenges of Validation

    NASA Technical Reports Server (NTRS)

    Koch, L. Danielle; Shook, Tony D.; Astler, Douglas T.; Bittinger, Samantha A.

    2011-01-01

    A fan tone noise prediction code has been developed at NASA Glenn Research Center that is capable of estimating duct mode sound power levels for a fan ingesting distorted inflow. This code was used to predict the circumferential and radial mode sound power levels in the inlet and exhaust duct of an axial spacecraft cabin ventilation fan. Noise predictions at fan design rotational speed were generated. Three fan inflow conditions were studied: an undistorted inflow, a circumferentially symmetric inflow distortion pattern (cylindrical rods inserted radially into the flowpath at 15deg, 135deg, and 255deg), and a circumferentially asymmetric inflow distortion pattern (rods located at 15deg, 52deg and 173deg). Noise predictions indicate that tones are produced for the distorted inflow cases that are not present when the fan operates with an undistorted inflow. Experimental data are needed to validate these acoustic predictions, as well as the aerodynamic performance predictions. Given the aerodynamic design of the spacecraft cabin ventilation fan, a mechanical and electrical conceptual design study was conducted. Design features of a fan suitable for obtaining detailed acoustic and aerodynamic measurements needed to validate predictions are discussed.

  19. Tone Noise Predictions for a Spacecraft Cabin Ventilation Fan Ingesting Distorted Inflow and the Challenges of Validation

    NASA Technical Reports Server (NTRS)

    Koch, L. Danielle; Shook, Tony D.; Astler, Douglas T.; Bittinger, Samantha A.

    2012-01-01

    A fan tone noise prediction code has been developed at NASA Glenn Research Center that is capable of estimating duct mode sound power levels for a fan ingesting distorted inflow. This code was used to predict the circumferential and radial mode sound power levels in the inlet and exhaust duct of an axial spacecraft cabin ventilation fan. Noise predictions at fan design rotational speed were generated. Three fan inflow conditions were studied: an undistorted inflow, a circumferentially symmetric inflow distortion pattern (cylindrical rods inserted radially into the flowpath at 15deg, 135deg, and 255deg), and a circumferentially asymmetric inflow distortion pattern (rods located at 15deg, 52deg and 173deg). Noise predictions indicate that tones are produced for the distorted inflow cases that are not present when the fan operates with an undistorted inflow. Experimental data are needed to validate these acoustic predictions, as well as the aerodynamic performance predictions. Given the aerodynamic design of the spacecraft cabin ventilation fan, a mechanical and electrical conceptual design study was conducted. Design features of a fan suitable for obtaining detailed acoustic and aerodynamic measurements needed to validate predictions are discussed.

  20. Characterization and evolution of exposure to volatile organic compounds in the Spanish shoemaking industry over a 5-year period.

    PubMed

    Estevan, Carmen; Ferri, Francisca; Sogorb, Miguel Angel; Vilanova, Eugenio

    2012-01-01

    This study measured inhalation exposure to 13 volatile organic compounds (VOCs) among workers in the leatherwear industry in Spain, examined the changes in those exposures over a 5-year period, and documented local exhaust ventilation practices that affected exposure. In collaboration with an occupational risk prevention company, air samples were collected from 849 workers' personal breathing zones using personal air pumps with activated charcoal tubes. VOCs were analyzed using a GC/MS-optimized method modified in our laboratory from that proposed by Spanish authorities (INSHT). Airborne concentrations were compared with occupational exposure limit (OEL) values from the European authorities. The most frequently detected VOCs were acetone (98.1%), toluene (94.8%), n-hexane (71.2%) and other C6-C7 branched alkyl hydrocarbons (97.5%). Other frequently detected VOCs were MEK (64.9%), ethylacetate (60.7%), and cyclohexane (29.3%). Benzene was detected in 24.6% of samples. Although all the samples were taken while workers performed tasks judged to have the highest VOC exposure potential, only 14% of samples showed excessive aggregate exposure, and chemical-specific OELs were exceeded in a relatively small number of cases: 7.2% for n-hexane, 2.8% for toluene, 0.6% for acetone, and 0.4% for hexane isomers. Over the study period, a diminished use of n-hexane in solvent formulations and an increased use of branched hexane and heptane isomers were observed. Six factors relating to work location conditions and types were evaluated. Most high-exposure cases were associated with three task types. The presence of local exhaust ventilation was an important exposure control, but significant exposures despite the use of local exhaust were observed. Although n-hexane exposures significantly decreased over the study period, the overall level of VOC exposure did not decrease. More effective exposure prevention measures need to be implemented.

  1. A first French assessment of population exposure to tetrachloroethylene from small dry-cleaning facilities.

    PubMed

    Chiappini, L; Delery, L; Leoz, E; Brouard, B; Fagault, Y

    2009-06-01

    Used as a solvent in the dry-cleaning industry, tetrachloroethylene (C(2)Cl(4)) can be a pollutant of residential indoor air, which can cause long-term harmful exposures because of its neurotoxicity and probable carcinogenicity. In France, dry-cleaning facilities are integrated in urban environments (shopping malls, residential buildings) and can contribute to C(2)Cl(4) exposure for customers and residents. This exploratory work presents the results from five studies carried out in one shopping mall and four residential buildings housing a dry-cleaning facility. These studies involved dry-cleaning machines fitted with a Carbon Adsorber and unfitted, with or without Air Exhaust System. Samples were collected in the cleaning facilities and in the apartments located above with passive samplers allowing measurement of time-integrated concentrations on a 7 days sampling period. It has obviously shown the degradation of indoor air quality in these environments and underlined the contributing role of the machine technology and ventilation system on the amount of released C(2)Cl(4) in the indoor air. To temper these results, it must be pointed out that some parameters (building insulation, amount of solvent used...) which would influence C(2)Cl(4) fugitive release have not been quantified and should be looked at in further studies. In France, dry-cleaning facilities are frequently integrated in urban environments (large shopping malls or residential buildings) and can significantly contribute to tetrachloroethylene (C(2)Cl(4)) population exposure. The amount of fugitive releases in these environments depends on several parameters such as the dry-cleaning machine technology (fitted or unfitted with a carbon adsorber) and the ventilation (air exhaust system). To reduce C(2)Cl(4) exposure in residential buildings and other indoor environments with on-site dry cleaners, carbon adsorber unequipped machine should be replaced by newer technology and dry cleaners should be equipped with mechanical air exhaust systems.

  2. Reducing float coal dust

    PubMed Central

    Patts, J.R.; Colinet, J.F.; Janisko, S.J.; Barone, T.L.; Patts, L.D.

    2016-01-01

    Controlling float coal dust in underground coal mines before dispersal into the general airstream can reduce the risk of mine explosions while potentially achieving a more effective and efficient use of rock dust. A prototype flooded-bed scrubber was evaluated for float coal dust control in the return of a continuous miner section. The scrubber was installed inline between the face ventilation tubing and an exhausting auxiliary fan. Airborne and deposited dust mass measurements were collected over three days at set distances from the fan exhaust to assess changes in float coal dust levels in the return due to operation of the scrubber. Mass-based measurements were collected on a per-cut basis and normalized on the basis of per ton mined by the continuous miner. The results show that average float coal dust levels measured under baseline conditions were reduced by more than 90 percent when operating the scrubber. PMID:28018004

  3. Utilization of coal mine ventilation exhaust as combustion air in gas-fired turbines for electric and/or mechanical power generation. Semi-annual topical report, June 1995--August 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-12-01

    Methane emitted during underground coal mining operations is a hazard that is dealt with by diluting the methane with fresh air and exhausting the contaminated air to the atmosphere. Unfortunately this waste stream may contain more than 60% of the methane resource from the coal, and in the atmosphere the methane acts as a greenhouse gas with an effect about 24.5 times greater than CO{sub 2}. Though the waste stream is too dilute for normal recovery processes, it can be used as combustion air for a turbine-generator, thereby reducing the turbine fuel requirements while reducing emissions. Preliminary analysis indicates thatmore » such a system, built using standard equipment, is economically and environmentally attractive, and has potential for worldwide application.« less

  4. Control technology for fiber reinforced plastics industry at AMF Hatteras Yachts, New Bern Division, New Bern, North Carolina

    NASA Astrophysics Data System (ADS)

    Todd, W. F.

    1984-05-01

    Area and breathing zone samples were analyzed for styrene (100425) at AMF Hatteras Yachts (SIC-3079), New Bern, North Carolina, in September, 1983. Control technology at the facility was inspected. Breathing zone styrene concentrations were 8 to 74 parts per million (ppm), the highest concentrations occurring in the lamination and gel coating departments. Area samples ranged from 1 to 20ppm. The OSHA standard is 100ppm. The hull lamination and assembly areas were ventilated by air make up units and exhaust blowers. Air exhausted through the lamination booths in the small parts work area was considerably less than the supply air from the make up units. The air flow in two of the three lamination booths was considered inadequate. Respirators were available if needed. Industrial hygiene sampling at the facility was supervised by the industrial hygienist.

  5. Liquid and Gaseous Waste Operations Department annual operating report CY 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maddox, J.J.; Scott, C.B.

    1997-03-01

    This annual report summarizes operating activities dealing with the process waste system, the liquid low-level waste system, and the gaseous waste system. It also describes upgrade activities dealing with the process and liquid low-level waste systems, the cathodic protection system, a stack ventilation system, and configuration control. Maintenance activities are described dealing with nonradiological wastewater treatment plant, process waste treatment plant and collection system, liquid low-level waste system, and gaseous waste system. Miscellaneous activities include training, audits/reviews/tours, and environmental restoration support.

  6. Effects of the window openings on the micro-environmental condition in a school bus

    NASA Astrophysics Data System (ADS)

    Li, Fei; Lee, Eon S.; Zhou, Bin; Liu, Junjie; Zhu, Yifang

    2017-10-01

    School bus is an important micro-environment for children's health because the level of in-cabin air pollution can increase due to its own exhaust in addition to on-road traffic emissions. However, it has been challenging to understand the in-cabin air quality that is associated with complex airflow patterns inside and outside a school bus. This study conducted Computational Fluid Dynamics (CFD) modeling analyses to determine the effects of window openings on the self-pollution for a school bus. Infiltration through the window gaps is modeled by applying variable numbers of active computational cells as a function of the effective area ratio of the opening. The experimental data on ventilation rates from the literature was used to validate the model. Ultrafine particles (UFPs) and black carbon (BC) concentrations were monitored in ;real world; field campaigns using school buses. This modeling study examined the airflow pattern inside the school bus under four different types of side-window openings at 20, 40, and 60 mph (i.e., a total of 12 cases). We found that opening the driver's window could allow the infiltration of exhaust through window/door gaps in the back of school bus; whereas, opening windows in the middle of the school bus could mitigate this phenomenon. We also found that an increased driving speed (from 20 mph to 60 mph) could result in a higher ventilation rate (up to 3.4 times) and lower mean age of air (down to 0.29 time) inside the bus.

  7. KSC-99pp1252

    NASA Image and Video Library

    1999-10-25

    The Zero Emissions (ZE) transit bus tours the KSC Visitor Complex for a test ride. In the background are a mock-up orbiter named Explorer (left) and a stack of solid rocket boosters and external tank (right), typically used on Shuttle launches. Provided by dbb fuel cell engines inc. of Vancouver, Canada, the ZE bus was brought to KSC as part of the Center's Alternative Fuel Initiatives Program. The bus uses a Proton Exchange Membrane fuel cell in which hydrogen and oxygen, from atmospheric air, react to produce electricity that powers an electric motor drive system. The by-product "exhaust" from the fuel cell is water vapor, thus zero harmful emissions. A typical diesel-powered bus emits more than a ton of harmful pollutants from its exhaust every year. The ZE bus is being used on tour routes at the KSC Visitor Complex for two days to introduce the public to the concept

  8. Solid oxide fuel cell power plant having a fixed contact oxidation catalyzed section of a multi-section cathode air heat exchanger

    DOEpatents

    Saito, Kazuo; Lin, Yao

    2015-02-17

    The multi-section cathode air heat exchanger (102) includes at least a first heat exchanger section (104), and a fixed contact oxidation catalyzed section (126) secured adjacent each other in a stack association. Cool cathode inlet air flows through cool air channels (110) of the at least first (104) and oxidation catalyzed sections (126). Hot anode exhaust flows through hot air channels (124) of the oxidation catalyzed section (126) and is combusted therein. The combusted anode exhaust then flows through hot air channels (112) of the first section (104) of the cathode air heat exchanger (102). The cool and hot air channels (110, 112) are secured in direct heat exchange relationship with each other so that temperatures of the heat exchanger (102) do not exceed 800.degree. C. to minimize requirements for using expensive, high-temperature alloys.

  9. Hydrogen-oxygen driven Zero Emissions bus drives around KSC Visitor Complex

    NASA Technical Reports Server (NTRS)

    1999-01-01

    The Zero Emissions (ZE) transit bus tours the KSC Visitor Complex for a test ride. In the background are a mock-up orbiter named Explorer (left) and a stack of solid rocket boosters and external tank (right), typically used on Shuttle launches. Provided by dbb fuel cell engines inc. of Vancouver, Canada, the ZE bus was brought to KSC as part of the Center's Alternative Fuel Initiatives Program. The bus uses a Proton Exchange Membrane fuel cell in which hydrogen and oxygen, from atmospheric air, react to produce electricity that powers an electric motor drive system. The by-product 'exhaust' from the fuel cell is water vapor, thus zero harmful emissions. A typical diesel-powered bus emits more than a ton of harmful pollutants from its exhaust every year. The ZE bus is being used on tour routes at the KSC Visitor Complex for two days to introduce the public to the concept.

  10. Solid oxide fuel cell anode degradation by the effect of hydrogen chloride in stack and single cell environments

    NASA Astrophysics Data System (ADS)

    Madi, Hossein; Lanzini, Andrea; Papurello, Davide; Diethelm, Stefan; Ludwig, Christian; Santarelli, Massimo; Van herle, Jan

    2016-09-01

    The poisoning effect by hydrogen chloride (HCl) on state-of-the-art Ni anode-supported solid oxide fuel cells (SOFCs) at 750 °C is evaluated in either hydrogen or syngas fuel. Experiments are performed on single cells and short stacks and HCl concentration in the fuel gas is increased from 1 ppm(v) up to 1000 ppm(v) at different current densities. Characterization methods such as cell voltage monitoring vs. time and electrochemical impedance response analysis (distribution of relaxation times (DRT), equivalent electrical circuit) are used to identify the prevailing degradation mechanism. Single cell experiments revealed that the poisoning is more severe when feeding with hydrogen than with syngas. Performance loss is attributed to the effects of HCl adsorption onto nickel surfaces, which lowered the catalyst activity. Interestingly, in syngas HCl does not affect stack performance even at concentrations up to 500 ppm(v), even when causing severe corrosion of the anode exhaust pipe. Furthermore, post-test analysis suggests that chlorine is present on the nickel particles in the form of adsorbed chlorine, rather than forming a secondary phase of nickel chlorine.

  11. Measurements and simulations of the optical gain and anti-reflection coating modal reflectivity in quantum cascade lasers with multiple active region stacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bidaux, Y., E-mail: yves.bidaux@alpeslasers.ch; Alpes Lasers SA, 1-3 Maximilien-de-Meuron, CH-2000 Neuchatel; Terazzi, R.

    2015-09-07

    We report spectrally resolved gain measurements and simulations for quantum cascade lasers (QCLs) composed of multiple heterogeneous stacks designed for broadband emission in the mid-infrared. The measurement method is first demonstrated on a reference single active region QCL based on a double-phonon resonance design emitting at 7.8 μm. It is then extended to a three-stack active region based on bound-to-continuum designs with a broadband emission range from 7.5 to 10.5 μm. A tight agreement is found with simulations based on a density matrix model. The latter implements exhaustive microscopic scattering and dephasing sources with virtually no fitting parameters. The quantitative agreement ismore » furthermore assessed by measuring gain coefficients obtained by studying the threshold current dependence with the cavity length. These results are particularly relevant to understand fundamental gain mechanisms in complex semiconductor heterostructure QCLs and to move towards efficient gain engineering. Finally, the method is extended to the measurement of the modal reflectivity of an anti-reflection coating deposited on the front facet of the broadband QCL.« less

  12. Carbon monoxide and nitrogen dioxide levels in an indoor ice skating rink with mitigation methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, K.; Yanagisawa, Y.; Spengler, J.D.

    1993-05-01

    An indoor ice skating rink is an enclosed space with intermittent air pollutant emissions from fuel-powered ice-resurfacing equipment, such as a resurfacer and an edger. Exhaust gases discharged from the resurfacing equipment actually include significant quantities of carbon monoxide (CO) and nitrogen dioxide (NO[sub 2]) which may induced adverse health effects. Carbon monoxide exposures in ice skating rinks resulting from malfunctioning ice resurfacing equipment were first reported more than twenty years ago. Attempts to reduce emissions of CO and NO[sub 2] form resurfacing equipment, such as the extended exhaust pipe, operation of the air recirculation system or reduced resurfacer operation,more » appeared not to be effective for maintaining the air pollutant concentrations below guidelines. Even though improved indoor air quality was obtained by the combination of the full operation of the air exhaust system and the reduced number of resurfacer operations in this investigation, these methods may be impractical for most skating rinks. Replacement of the fuel-powered resurfacer with a battery operated resurfacer is recommended. If replacement is not feasible, then increasing the air ventilation rate is recommended as a second choice. 10 refs., 1 fig., 1 tab.« less

  13. Modeling and optimization of the air system in polymer exchange membrane fuel cell systems

    NASA Astrophysics Data System (ADS)

    Bao, Cheng; Ouyang, Minggao; Yi, Baolian

    Stack and air system are the two most important components in the fuel cell system (FCS). It is meaningful to study their properties and the trade-off between them. In this paper, a modified one-dimensional steady-state analytical fuel cell model is used. The logarithmic mean of the inlet and the outlet oxygen partial pressure is adopted to avoid underestimating the effect of air stoichiometry. And the pressure drop model in the grid-distributed flow field is included in the stack analysis. Combined with the coordinate change preprocessing and analog technique, neural network is used to treat the MAP of compressor and turbine in the air system. Three kinds of air system topologies, the pure screw compressor, serial booster and exhaust expander are analyzed in this article. A real-code genetic algorithm is programmed to obtain the global optimum air stoichiometric ratio and the cathode outlet pressure. It is shown that the serial booster and expander with the help of exhaust recycling, can improve more than 3% in the FCS efficiency comparing to the pure screw compressor. As the net power increases, the optimum cathode outlet pressure keeps rising and the air stoichiometry takes on the concave trajectory. The working zone of the proportional valve is also discussed. This presented work is helpful to the design of the air system in fuel cell system. The steady-state optimum can also be used in the dynamic control.

  14. Relationship between arterial oxygen desaturation and ventilation during maximal exercise.

    PubMed

    Miyachi, M; Tabata, I

    1992-12-01

    The purpose of the present study was to investigate the contribution of ventilation to arterial O2 desaturation during maximal exercise. Nine untrained subjects and 22 trained long-distance runners [age 18-36 yr, maximal O2 uptake (VO2max) 48-74 ml.min-1 x kg-1] volunteered to participate in the study. The subjects performed an incremental exhaustive cycle ergometry test at 70 rpm of pedaling frequency, during which arterial O2 saturation (SaO2) and ventilatory data were collected every minute. SaO2 was estimated with a pulse oximeter. A significant positive correlation was found between SaO2 and end-tidal PO2 (PETO2; r = 0.72, r2 = 0.52, P < 0.001) during maximal exercise. These statistical results suggest that approximately 50% of the variability of SaO2 can be accounted for by differences in PETO2, which reflects alveolar PO2. Furthermore, PETO2 was highly correlated with the ventilatory equivalent for O2 (VE/VO2; r = 0.91, P < 0.001), which indicates that PETO2 could be the result of ventilation stimulated by maximal exercise. Finally, SaO2 was positively related to VE/VO2 during maximal exercise (r = 0.74, r2 = 0.55, P < 0.001). Therefore, one-half of the arterial O2 desaturation occurring during maximal exercise may be explained by less hyperventilation, specifically for our subjects, who demonstrated a wide range of trained states. Furthermore, we found an indirect positive correlation between SaO2 and ventilatory response to CO2 at rest (r = 0.45, P < 0.05), which was mediated by ventilation during maximal exercise. These data also suggest that ventilation is an important factor for arterial O2 desaturation during maximal exercise.

  15. Measured performance of filtration and ventilation systems for fine and ultrafine particles and ozone in an unoccupied modern California house.

    PubMed

    Singer, B C; Delp, W W; Black, D R; Walker, I S

    2017-07-01

    This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250 m downwind of the I-80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir-fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year-round operation in California. Exhaust ventilation without enhanced filtration provided indoor PM 2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection, whereas supply MERV16 filtration reduced PM 2.5 by 97-98% relative to outdoors. Supply filtration systems used little energy but provided no benefits for indoor-generated particles. Systems with MERV13-16 filter in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM 2.5 by 93-98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM 2.5 . Indoor ozone was 3-4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM 2.5 by 25-75% when operated over the hour following cooking. The energy for year-round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Health outcomes and green renovation of affordable housing.

    PubMed

    Breysse, Jill; Jacobs, David E; Weber, William; Dixon, Sherry; Kawecki, Carol; Aceti, Susan; Lopez, Jorge

    2011-01-01

    This study sought to determine whether renovating low-income housing using "green" and healthy principles improved resident health and building performance. We investigated resident health and building performance outcomes at baseline and one year after the rehabilitation of low-income housing using Enterprise Green Communities green specifications, which improve ventilation; reduce moisture, mold, pests, and radon; and use sustainable building products and other healthy housing features. We assessed participant health via questionnaire, provided Healthy Homes training to all participants, and measured ventilation, carbon dioxide, and radon. Adults reported statistically significant improvements in overall health, asthma, and non-asthma respiratory problems. Adults also reported that their children's overall health improved, with significant improvements in non-asthma respiratory problems. Post-renovation building performance testing indicated that the building envelope was tightened and local exhaust fans performed well. New mechanical ventilation was installed (compared with no ventilation previously), with fresh air being supplied at 70% of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers standard. Radon was < 2 picocuries per liter of air following mitigation, and the annual average indoor carbon dioxide level was 982 parts per million. Energy use was reduced by 45% over the one-year post-renovation period. We found significant health improvements following low-income housing renovation that complied with green standards. All green building standards should include health requirements. Collaboration of housing, public health, and environmental health professionals through integrated design holds promise for improved health, quality of life, building operation, and energy conservation.

  17. Health Outcomes and Green Renovation of Affordable Housing

    PubMed Central

    Breysse, Jill; Jacobs, David E.; Weber, William; Dixon, Sherry; Kawecki, Carol; Aceti, Susan; Lopez, Jorge

    2011-01-01

    Objective This study sought to determine whether renovating low-income housing using “green” and healthy principles improved resident health and building performance. Methods We investigated resident health and building performance outcomes at baseline and one year after the rehabilitation of low-income housing using Enterprise Green Communities green specifications, which improve ventilation; reduce moisture, mold, pests, and radon; and use sustainable building products and other healthy housing features. We assessed participant health via questionnaire, provided Healthy Homes training to all participants, and measured ventilation, carbon dioxide, and radon. Results Adults reported statistically significant improvements in overall health, asthma, and non-asthma respiratory problems. Adults also reported that their children's overall health improved, with significant improvements in non-asthma respiratory problems. Post-renovation building performance testing indicated that the building envelope was tightened and local exhaust fans performed well. New mechanical ventilation was installed (compared with no ventilation previously), with fresh air being supplied at 70% of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers standard. Radon was <2 picocuries per liter of air following mitigation, and the annual average indoor carbon dioxide level was 982 parts per million. Energy use was reduced by 45% over the one-year post-renovation period. Conclusions We found significant health improvements following low-income housing renovation that complied with green standards. All green building standards should include health requirements. Collaboration of housing, public health, and environmental health professionals through integrated design holds promise for improved health, quality of life, building operation, and energy conservation. PMID:21563714

  18. Measured performance of filtration and ventilation systems for fine and ultrafine particles and ozone in an unoccupied modern California house

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, Brett C.; Delp, William W.; Black, Douglas R.

    This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250m downwind of the I-80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir-fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year-round operation in California. Exhaust ventilation without enhanced filtration produced indoor PM 2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection whereas supply MERV16 filtration reduced PM 2.55 by 97-98% relative to outdoors. Supply filtration systems usedmore » little energy but provided no benefits for indoor-generated particles. Systems with MERV13-16 filters in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM 2.5 by 93-98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM 2.5. Indoor ozone was 3-4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM 2.5 by 25-75% when operated over the hour following cooking. The energy for year-round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year.« less

  19. Measured performance of filtration and ventilation systems for fine and ultrafine particles and ozone in an unoccupied modern California house

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, B. C.; Delp, W. W.; Black, D. R.

    This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250 m downwind of the I-80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir-fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year-round operation in California. Exhaust ventilation without enhanced filtration provided indoor PM 2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection, whereas supply MERV16 filtration reduced PM 2.5 by 97-98% relative to outdoors. Supply filtration systems usedmore » little energy but provided no benefits for indoor-generated particles. Systems with MERV13-16 fil ter in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM 2.5 by 93-98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM 2.5 . Indoor ozone was 3-4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM 2.5 by 25-75% when operated over the hour following cooking. The energy for year-round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year.« less

  20. Measured performance of filtration and ventilation systems for fine and ultrafine particles and ozone in an unoccupied modern California house

    DOE PAGES

    Singer, B. C.; Delp, W. W.; Black, D. R.; ...

    2016-12-05

    This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250 m downwind of the I-80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir-fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year-round operation in California. Exhaust ventilation without enhanced filtration provided indoor PM 2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection, whereas supply MERV16 filtration reduced PM 2.5 by 97-98% relative to outdoors. Supply filtration systems usedmore » little energy but provided no benefits for indoor-generated particles. Systems with MERV13-16 fil ter in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM 2.5 by 93-98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM 2.5 . Indoor ozone was 3-4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM 2.5 by 25-75% when operated over the hour following cooking. The energy for year-round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year.« less

  1. SBS symptoms in relation to dampness and ventilation in inspected single-family houses in Sweden.

    PubMed

    Smedje, Greta; Wang, Juan; Norbäck, Dan; Nilsson, Håkan; Engvall, Karin

    2017-10-01

    To investigate the relationships between symptoms compatible with the sick building syndrome (SBS) in adults and building dampness and ventilation in single-family houses. Within the Swedish BETSI study, a national sample of single-family houses were inspected by professional building experts, and adults living in the houses answered a questionnaire on SBS. Relationships between building factors and SBS were analysed using logistic regression. Of the respondents, 23% reported having had weekly SBS symptoms during the last three months. A large proportion of houses exhibited building or construction problems. In total, 40% of houses had dampness problems in the foundation, and this was related to a higher prevalence of both mucous and dermal symptoms, and any SBS symptoms. Furthermore, high air humidity was related to more symptoms, with the relationship with absolute humidity being stronger than that with relative humidity or moisture load. Symptoms were also more prevalent in houses with a high U value, reflecting a poor thermal insulation. Compared to natural ventilation, living in a house with mechanical supply and exhaust ventilation was related to a lower prevalence of general symptoms and any SBS symptoms, but there were only weak associations between measured air exchange rate and symptoms. A large proportion of single-family houses have dampness problems in the foundation, and pollutants may enter the living space of the house and affect the health of the occupants. Furthermore, absolute air humidity should be measured more often in indoor air studies.

  2. Analysis Thermal Comfort Condition in Complex Residential Building, Case Study: Chiangmai, Thailand

    NASA Astrophysics Data System (ADS)

    Juangjandee, Warangkana

    2017-10-01

    Due to the increasing need for complex residential buildings, it appears that people migrate into the high-density urban areas because the infrastructural facilities can be easily found in the modern metropolitan areas. Such rapid growth of urbanization creates congested residential buildings obstructing solar radiation and wind flow, whereas most urban residents spend 80-90% of their time indoor. Furthermore, the buildings were mostly built with average materials and construction detail. This causes high humidity condition for tenants that could promote mould growth. This study aims to analyse thermal comfort condition in complex residential building, Thailand for finding the passive solution to improve indoor air quality and respond to local conditions. The research methodology will be in two folds: 1) surveying on case study 2) analysis for finding the passive solution of reducing humidity indoor air The result of the survey indicated that the building need to find passive solution for solving humidity problem, that can be divided into two ways which raising ventilation and indoor temperature including increasing wind-flow ventilation and adjusting thermal temperature, for example; improving building design and stack driven ventilation. For raising indoor temperature or increasing mean radiant temperature, daylight can be passive solution for complex residential design for reducing humidity and enhance illumination indoor space simultaneous.

  3. Acceptance test procedure bldg. 271-U remote monitoring of project W-059 B-Plant canyon exhaust system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MCDANIEL, K.S.

    1999-09-01

    The test procedure provides for verifying indications and alarms The test procedure provides for verifying indications and alarms associated with the B Plant Canyon Ventilation System as they are being displayed on a remote monitoring workstation located in building 271-U. The system application software was installed by PLCS Plus under contract from B&W Hanford Company. The application software was installed on an existing operator workstation in building 271U which is owned and operated by Bechtel Hanford Inc.

  4. Meeting the Challenge: A 1986 History of the Naval Surface Weapons Center

    DTIC Science & Technology

    1987-05-29

    8217GClK JACK lMUITRIUXER DIG Iot I ---, , SUpFt S COMPUTER ’ HEL DE Osi cOeiTROLPRiOCESSO HIGM SPEED ATA BUS OM SWR AU VAGKTtC BIBS11 Closed-Loop...appear. HVAC designers think it can determine if closures need to be installed on ventilation inlets to prevent the ingress of exhaust gases from...and fuze timing errors. If the fuze could be caused to actuate based on target position rather than a predicted time of flight, these errors could be

  5. Patient warming excess heat: the effects on orthopedic operating room ventilation performance.

    PubMed

    Belani, Kumar G; Albrecht, Mark; McGovern, Paul D; Reed, Mike; Nachtsheim, Christopher

    2013-08-01

    Patient warming has become a standard of care for the prevention of unintentional hypothermia based on benefits established in general surgery. However, these benefits may not fully translate to contamination-sensitive surgery (i.e., implants), because patient warming devices release excess heat that may disrupt the intended ceiling-to-floor ventilation airflows and expose the surgical site to added contamination. Therefore, we studied the effects of 2 popular patient warming technologies, forced air and conductive fabric, versus control conditions on ventilation performance in an orthopedic operating room with a mannequin draped for total knee replacement. Ventilation performance was assessed by releasing neutrally buoyant detergent bubbles ("bubbles") into the nonsterile region under the head-side of the anesthesia drape. We then tracked whether the excess heat from upper body patient warming mobilized the "bubbles" into the surgical site. Formally, a randomized replicated design assessed the effect of device (forced air, conductive fabric, control) and anesthesia drape height (low-drape, high-drape) on the number of bubbles photographed over the surgical site. The direct mass-flow exhaust from forced air warming generated hot air convection currents that mobilized bubbles over the anesthesia drape and into the surgical site, resulting in a significant increase in bubble counts for the factor of patient warming device (P < 0.001). Forced air had an average count of 132.5 versus 0.48 for conductive fabric (P = 0.003) and 0.01 for control conditions (P = 0.008) across both drape heights. Differences in average bubble counts across both drape heights were insignificant between conductive fabric and control conditions (P = 0.87). The factor of drape height had no significant effect (P = 0.94) on bubble counts. Excess heat from forced air warming resulted in the disruption of ventilation airflows over the surgical site, whereas conductive patient warming devices had no noticeable effect on ventilation airflows. These findings warrant future research into the effects of forced air warming excess heat on clinical outcomes during contamination-sensitive surgery.

  6. Computer software configuration description, 241-AY and 241-AZ tank farm MICON automation system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winkelman, W.D.

    This document describes the configuration process, choices and conventions used during the configuration activities, and issues involved in making changes to the configuration. Includes the master listings of the Tag definitions, which should be revised to authorize any changes. Revision 2 incorporates minor changes to ensure the document setpoints accurately reflect limits (including exhaust stack flow of 800 scfm) established in OSD-T-151-00019. The MICON DCS software controls and monitors the instrumentation and equipment associated with plant systems and processes.

  7. 60. VIEW OF ROASTER ADDITION FROM WEST, LOCATION OF SYMONS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. VIEW OF ROASTER ADDITION FROM WEST, LOCATION OF SYMONS 3 BY 8 FEET VIBRATING SCREEN. SHOWS BAKER COOLER WITH DUST COLLECTOR DUCT AND DISCHARGE CHUTE ON LEFT. THE 14 INCH BELT CONVEYOR WAS SUPPORTED ON TWO BENTS IN CENTER OF VIEW AS IT CONNECTED WITH THE BUCKET ELEVATOR/ORE BIN TOWER, WHICH IN TURN FED THE ROASTER (BEHIND). THE BASE OF THE ROASTER EXHAUST STACK IS AT THE UPPER RIGHT. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  8. Air Leakage and Air Transfer Between Garage and Living Space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudd, Armin

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressuremore » relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.« less

  9. Compilation of Published PM2.5 Emission Rates for Cooking, Candles and Incense for Use in Modeling of Exposures in Residences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Tianchao; Singer, Brett C.; Logue, Jennifer M.

    2012-08-01

    recent analysis of health impacts from air pollutant inhalation in homes found that PM2.5 is the most damaging at the population level. Chronic exposure to elevated PM2.5 has the potential to damage human respiratory systems, and may result in premature death. PM2.5 exposures in homes can be mitigated through various approaches including kitchen exhaust ventilation, filtration, indoor pollutant source reduction and designing ventilation systems to reduce the entry of PM2.5 from outdoors. Analysis of the potential benefits and costs of various approaches can be accomplished using computer codes that simulate the key physical processes including emissions, dilution and ventilation. Themore » largest sources of PM2.5 in residences broadly are entry from outdoors and emissions from indoor combustion. The largest indoor sources are tobacco combustion (smoking), cooking and the burning of candles and incense. Data on the magnitude of PM2.5 and other pollutant emissions from these events and processes are required to conduct simulations for analysis. The goal of this study was to produce a database of pollutant emission rates associated with cooking and the burning of candles and incense. The target use of these data is for indoor air quality modeling.« less

  10. Horses Auto-Recruit Their Lungs by Inspiratory Breath Holding Following Recovery from General Anaesthesia

    PubMed Central

    Mosing, Martina; Waldmann, Andreas D.; MacFarlane, Paul; Iff, Samuel; Auer, Ulrike; Bohm, Stephan H.; Bettschart-Wolfensberger, Regula; Bardell, David

    2016-01-01

    This study evaluated the breathing pattern and distribution of ventilation in horses prior to and following recovery from general anaesthesia using electrical impedance tomography (EIT). Six horses were anaesthetised for 6 hours in dorsal recumbency. Arterial blood gas and EIT measurements were performed 24 hours before (baseline) and 1, 2, 3, 4, 5 and 6 hours after horses stood following anaesthesia. At each time point 4 representative spontaneous breaths were analysed. The percentage of the total breath length during which impedance remained greater than 50% of the maximum inspiratory impedance change (breath holding), the fraction of total tidal ventilation within each of four stacked regions of interest (ROI) (distribution of ventilation) and the filling time and inflation period of seven ROI evenly distributed over the dorso-ventral height of the lungs were calculated. Mixed effects multi-linear regression and linear regression were used and significance was set at p<0.05. All horses demonstrated inspiratory breath holding until 5 hours after standing. No change from baseline was seen for the distribution of ventilation during inspiration. Filling time and inflation period were more rapid and shorter in ventral and slower and longer in most dorsal ROI compared to baseline, respectively. In a mixed effects multi-linear regression, breath holding was significantly correlated with PaCO2 in both the univariate and multivariate regression. Following recovery from anaesthesia, horses showed inspiratory breath holding during which gas redistributed from ventral into dorsal regions of the lungs. This suggests auto-recruitment of lung tissue which would have been dependent and likely atelectic during anaesthesia. PMID:27331910

  11. Exposures and their determinants in radiographic film processing.

    PubMed

    Teschke, Kay; Chow, Yat; Brauer, Michael; Chessor, Ed; Hirtle, Bob; Kennedy, Susan M; Yeung, Moira Chan; Ward, Helen Dimich

    2002-01-01

    Radiographers process X-ray films using developer and fixer solutions that contain chemicals known to cause or exacerbate asthma. In a study in British Columbia, Canada, radiographers' personal exposures to glutaraldehyde (a constituent of the developer chemistry), acetic acid (a constituent of the fixer chemistry), and sulfur dioxide (a byproduct of sulfites, present in both developer and fixer solutions) were measured. Average full-shift exposures to glutaraldehyde, acetic acid, and sulfur dioxide were 0.0009 mg/m3, 0.09 mg/m3, and 0.08 mg/m3, respectively, all more than one order of magnitude lower than current occupational exposure limits. Local exhaust ventilation of the processing machines and use of silver recovery units lowered exposures, whereas the number of films processed per machine and the time spent near the machines increased exposures. Personnel in clinic facilities had higher exposures than those in hospitals. Private clinics were less likely to have local exhaust ventilation and silver recovery units. Their radiographers spent more time in the processor areas and processed more films per machine. Although exposures were low compared with exposure standards, there are good reasons to continue practices to minimize or eliminate exposures: glutaraldehyde and hydroquinone (present in the developer) are sensitizers; the levels at which health effects occur are not yet clearly established, but appear to be lower than current standards; and health effects resulting from the mixture of chemicals are not understood. Developments in digital imaging technology are making available options that do not involve wet-processing of photographic film and therefore could eliminate the use of developer and fixer chemicals altogether.

  12. Exposures to nanoparticles and fibers during injection molding and recycling of carbon nanotube reinforced polycarbonate composites.

    PubMed

    Boonruksa, Pongsit; Bello, Dhimiter; Zhang, Jinde; Isaacs, Jacqueline A; Mead, Joey L; Woskie, Susan R

    2017-07-01

    In this study, the characteristics of airborne particles generated during injection molding and grinding processes of carbon nanotube reinforced polycarbonate composites (CNT-PC) were investigated. Particle number concentration, size distribution, and morphology of particles emitted from the processes were determined using real-time particle sizers and transmission electron microscopy. The air samples near the operator's breathing zone were collected on filters and analyzed using scanning electron microscope for particle morphology and respirable fiber count. Processing and grinding during recycling of CNT-PC released airborne nanoparticles (NPs) with a geometric mean (GM) particle concentration from 4.7 × 10 3 to 1.7 × 10 6 particles/cm 3 . The ratios of the GM particle concentration measured during the injection molding process with exhaust ventilation relative to background were up to 1.3 (loading), 1.9 (melting), and 1.4 (molding), and 101.4 for grinding process without exhaust ventilation, suggesting substantial NP exposures during these processes. The estimated mass concentration was in the range of 1.6-95.2 μg/m 3 . Diverse particle morphologies, including NPs, NP agglomerates, particles with embedded or protruding CNTs and fibers, were observed. No free CNTs were found during any of the investigated processes. The breathing zone respirable fiber concentration during the grinding process ranged from non-detectable to 0.13 fiber/cm 3 . No evidence was found that the emissions were affected by the number of recycling cycles. Institution of exposure controls is recommended during these processes to limit exposures to airborne NPs and CNT-containing fibers.

  13. Temporal evolution of ultrafine particles and of alveolar deposited surface area from main indoor combustion and non-combustion sources in a model room.

    PubMed

    Manigrasso, Maurizio; Vitali, Matteo; Protano, Carmela; Avino, Pasquale

    2017-11-15

    Aerosol number size distributions, PM mass concentrations, alveolar deposited surface areas (ADSAs) and VOC concentrations were measured in a model room when aerosol was emitted by sources frequently encountered in indoor environments. Both combustion and non-combustion sources were considered. The most intense aerosol emission occurred when combustion sources were active (as high as 4.1×10 7 particlescm -3 for two meat grilling sessions; the first with exhaust ventilation, the second without). An intense spike generation of nucleation particles occurred when appliances equipped with brush electric motors were operating (as high as 10 6 particlescm -3 on switching on an electric drill). Average UFP increments over the background value were highest for electric appliances (5-12%) and lowest for combustion sources (as low as -24% for tobacco cigarette smoke). In contrast, average increments in ADSA were highest for combustion sources (as high as 3.2×10 3 μm 2 cm -3 for meat grilling without exhaust ventilation) and lowest for electric appliances (20-90μm 2 cm -3 ). The health relevance of such particles is associated to their ability to penetrate cellular structures and elicit inflammatory effects mediated through oxidative stress in a way dependent on their surface area. The highest VOC concentrations were measured (PID probe) for cigarette smoke (8ppm) and spray air freshener (10ppm). The highest PM mass concentration (PM 1 ) was measured for citronella candle burning (as high as 7.6mgm -3 ). Copyright © 2017 Elsevier B.V. All rights reserved.

  14. [The working environment control of anhydride hardeners from an epoxy resin system].

    PubMed

    Matsumoto, Naomi; Yokota, Kozo; Johyama, Yasushi; Takakura, Toshiyuki

    2003-07-01

    Epoxy resins are widely used in adhesives, coatings, materials for molds and composites, and encapsulation. Acid anhydrides such as methyltetrahydrophthalic anhydride are being used as curing agents for epoxy resins. The anhydride hardeners are well-known industrial inhalant allergens, inducing predominantly type I allergies. In the electronic components industry, these substances have been consumed in large quantities. Therefore, safe use in the industry demands control of the levels of exposure causing allergic diseases in the workshop. We conducted a prospective survey of two electronics plants to clarify how to control the atmospheric level of the anhydrides in the work environment. Measurements of the levels of the anhydrides in air started according to the Working Environment Measurement Standards (Ministry of Labour Notification No. 46, 1976) in April 2000, along with improvements in the work environment. A value of 40 micrograms/m3 was adopted as the administrative control level to judge the propriety of the working environment control. A total of 2 unit work areas in both plants belonged to Control Class III. The exposure originated from manual loading, casting, uncured hot resins, and leaks in an impregnating-machine or curing ovens. In order to achieve the working environment control, complete enclosure of the source, installation of local exhaust ventilation, and improvement or maintenance of the local exhaust ventilation system were performed on the basis of the results of the working environment measurement, with the result that the work environment was improved (Control Class I). It became evident that these measures were effective just like other noxious substances.

  15. Stereoscopic particle image velocimetry investigations of the mixed convection exchange flow through a horizontal vent

    NASA Astrophysics Data System (ADS)

    Varrall, Kevin; Pretrel, Hugues; Vaux, Samuel; Vauquelin, Olivier

    2017-10-01

    The exchange flow through a horizontal vent linking two compartments (one above the other) is studied experimentally. This exchange is here governed by both the buoyant natural effect due to the temperature difference of the fluids in both compartments, and the effect of a (forced) mechanical ventilation applied in the lower compartment. Such a configuration leads to uni- or bi-directional flows through the vent. In the experiments, buoyancy is induced in the lower compartment thanks to an electrical resistor. The forced ventilation is applied in exhaust or supply modes and three different values of the vent area. To estimate both velocity fields and flow rates at the vent, measurements are realized at thermal steady state, flush the vent in the upper compartment using stereoscopic particle image velocimetry (SPIV), which is original for this kind of flow. The SPIV measurements allows the area occupied by both upward and downward flows to be determined.

  16. Assessment of airborne bacteria and noroviruses in air emission from a new highly-advanced hospital wastewater treatment plant.

    PubMed

    Uhrbrand, K; Schultz, A C; Koivisto, A J; Nielsen, U; Madsen, A M

    2017-04-01

    Exposure to bioaerosols can pose a health risk to workers at wastewater treatment plants (WWTPs) and to habitants of their surroundings. The main objective of this study was to examine the presence of harmful microorganisms in the air emission from a new type of hospital WWTP employing advanced wastewater treatment technologies. Air particle measurements and sampling of inhalable bacteria, endotoxin and noroviruses (NoVs) were performed indoor at the WWTP and outside at the WWTP ventilation air exhaust, downwind of the air exhaust, and upwind of the WWTP. No significant differences were seen in particle and endotoxin concentrations between locations. Bacterial concentrations were comparable or significantly lower in the exhaust air than inside the WWTP and in the upwind reference. Bacterial isolates were identified using matrix-assisted laser desorption-ionization time-of-flight mass spectrometry. In total, 35 different bacterial genera and 64 bacterial species were identified in the air samples. Significantly higher genus and species richness was found with an Andersen Cascade Impactor compared with filter-based sampling. No pathogenic bacteria were found in the exhaust air. Streptomyces was the only bacterium found in the air both inside the WWTP and at the air emission, but not in the upwind reference. NoV genomes were detected in the air inside the WWTP and at the air exhaust, albeit in low concentrations. As only traces of NoV genomes could be detected in the exhaust air they are unlikely to pose a health risk to surroundings. Hence, we assess the risk of airborne exposure to pathogenic bacteria and NoVs from the WWTP air emission to surroundings to be negligible. However, as a slightly higher NoV concentration was detected inside the WWTP, we cannot exclude the possibility that exposure to airborne NoVs can pose a health risk to susceptible to workers inside the WWTP, although the risk may be low. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Research of carbon composite material for nonlinear finite element method

    NASA Astrophysics Data System (ADS)

    Kim, Jung Ho; Garg, Mohit; Kim, Ji Hoon

    2012-04-01

    Works on the absorption of collision energy in the structural members are carried out widely with various material and cross-sections. And, with ever increasing safety concerns, they are presently applied in various fields including railroad trains, air crafts and automobiles. In addition to this, problem of lighting structural members became important subject by control of exhaust gas emission, fuel economy and energy efficiency. CFRP(Carbon Fiber Reinforced Plastics) usually is applying the two primary structural members because of different result each design parameter as like stacking thickness, stacking angle, moisture absorption ect. We have to secure the data for applying primary structural members. But it always happens to test design parameters each for securing the data. So, it has much more money and time. We can reduce the money and the time, if can ensure the CFRP material properties each design parameters. In this study, we experiment the coupon test each tension, compression and shear using CFRP prepreg sheet and simulate non-linear analyze at the sources - test result, Caron longitudinal modulus and matrix poisson's ratio using GENOAMQC is specialized at Composite analysis. And then we predict the result that specimen manufacture changing stacking angle and experiment in such a way of test method using GENOA-MCQ.

  18. Exercise to exhaustion in the second-wind phase of exercise in a case of McArdle's disease with and without creatine supplementation.

    PubMed

    O'Reilly, D St J; Carter, R; Bell, E; Hinnie, J; Galloway, P J

    2003-05-01

    The cardio-pulmonary and biochemical changes observed in a case of McArdle's disease, exercising with increasing work rates to exhaustion in the "second-wind" phase of exercise are reported for the first time. A work rate of 275-325 watts was achieved. Venous blood lactate remained unchanged throughout. The plasma ammonium level reached a plateau of approximately 400 mmol/l at 100 watts. At a work rate of 150-175 watts the ratio of O2 consumption to CO2 production increased, the inverse of an anaerobic threshold. Maximal cardiopulmonary responses were achieved at 200 watts. During the final periods of exercise from 200 to 275/325 watts pulmonary ventilation did not significantly change but there was a decrease in the venous blood H+ concentration, and pO2 and in increase in the pCO2. Creatine supplementation at 25 g/day for five days did not improve exercise performance.

  19. Numerical analysis for temperature profile of the closed house using computational fluid dynamics

    NASA Astrophysics Data System (ADS)

    Setiadi, Rizki; Munadi, Tauviqirrahman, Mohammad

    2018-03-01

    This study aims to analyze the air temperature distribution in the closed house system for broiler using ABAQUS CFD Model. The obtained data is used for placing the temperature sensor before making the control system for the closed house. The dimesion of the experimental house was 30 m × 12 m × 2 m (length × width × height) which could be occupied by 7.500 broiler. The wall was made from expose mercy brick and curtain, ventilation system used 7 exhaust fan with diameter 1 m and 2 cooling unit, the roof was made from wood, and system used 45 of 7 watt lamp. The results of the analysis show that temperature distribution occurs on temperature 21-33.5°C and still relatively comfortable for broiler at the age of 1-21days. The air temperature distribution near the cooling unit is lower and increases to near the exhaust fan. In addition, the air temperature in the area near the roof is more high than others.

  20. The effect of commuting microenvironment on commuter exposures to vehicular emission in Hong Kong

    NASA Astrophysics Data System (ADS)

    Chan, L. Y.; Chan, C. Y.; Qin, Y.

    Vehicular exhaust emission has gradually become the major air pollution source in modern cities and traffic related exposure is found to contribute significantly to total human exposure level. A comprehensive survey was conducted from November 1995 to July 1996 in Hong Kong to assess the effect of traffic-induced air pollution inside different commuting microenvironments on commuter exposure. Microenvironmental monitoring is performed for six major public commuting modes (bus, light bus, MTR, railway, tram, ferry), plus private car and roadside pavement. Traffic-related pollutants, CO, NO x, THC and O 3 were selected as the target pollutants. The results indicate that commuter exposure is highly influenced by the choice of commuting microenvironment. In general, the exposure level in decreasing order of measured pollutant level for respective commuting microenvironments are: private car, the group consisting light bus, bus, tram and pavement, MTR and train, and finally ferry. In private car, the CO level is several times higher than that in the other microenvironments with a trip averaged of 10.1 ppm and a maximum of 24.9 ppm. Factors such as the body position of the vehicle, intake point of the ventilation system, fuel used, ventilation, transport mode, road and driving conditions were used in the analysis. Inter-microenvironment, intra-microenvironment and temporal variation of CO concentrations were used as the major indicator. The low body position and low intake point of the ventilation system of the private car are believed to be the cause of higher intake of exhaust of other vehicles and thus result in high pollution level in this microenvironment. Compared with other metropolis around the world and the Hong Kong Air Quality Objectives (HKAQO), exposure levels of commuter to traffic-related air pollution in Hong Kong are relatively low for most pollutants measured. Only several cases of exceedence of HKAQO by NO 2 were recorded. The strong prevailing wind plus the channeling effect created by the harbor, the fuel used, the relative abundance of new cars and the successful implementation of the vehicle emission control program are factors that compensate the effect of the emission source strength and thus lead to low exposure levels.

  1. Effects of a capacitive-resistive electric transfer therapy on physiological and biomechanical parameters in recreational runners: A randomized controlled crossover trial.

    PubMed

    Duñabeitia, Iratxe; Arrieta, Haritz; Torres-Unda, Jon; Gil, Javier; Santos-Concejero, Jordan; Gil, Susana M; Irazusta, Jon; Bidaurrazaga-Letona, Iraia

    2018-05-26

    This study compared the effects of a capacitive-resistive electric transfer therapy (Tecar) and passive rest on physiological and biomechanical parameters in recreational runners when performed shortly after an exhausting training session. Randomized controlled crossover trial. University biomechanical research laboratory. Fourteen trained male runners MAIN OUTCOME MEASURES: Physiological (running economy, oxygen uptake, respiratory exchange ratio, ventilation, heart rate, blood lactate concentration) and biomechanical (step length; stride angle, height, frequency, and contact time; swing time; contact phase; support phase; push-off phase) parameters were measured during two incremental treadmill running tests performed two days apart after an exhaustive training session. When running at 14 km/h and 16 km/h, the Tecar treatment group presented greater increases in stride length (p < 0.001), angle (p < 0.05) and height (p < 0.001) between the first and second tests than the control group and, accordingly, greater decreases in stride frequency (p < 0.05). Physiological parameters were similar between groups. The present study suggests that a Tecar therapy intervention enhances biomechanical parameters in recreational runners after an exhaustive training session more than passive rest, generating a more efficient running pattern without affecting selected physiological parameters. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Accidental Carbon Monoxide Poisoning While Driving: A Case Report With Review of the Literature.

    PubMed

    Fisher-Hubbard, Amanda O; Appleford, Colin; Kesha, Kilak; Schmidt, Carl J; Gupta, Avneesh

    2018-05-16

    Carbon monoxide (CO) is the cause of a significant percentage of fatal poisonings in many countries. It is known that fatalities resulting from CO poisoning are underreported and/or misclassified. Carbon monoxide exposure while driving can occur due to faulty exhaust systems, defective ventilation systems, emission from other vehicles, and even cigarette smoking. We report the case of a 23-year-old woman who was involved in a low-speed motor vehicle collision and was found unresponsive in her vehicle due to CO poisoning. A review of the literature revealed rare vehicle-related accidental CO poisonings.

  3. Analysis of multiple jets in a cross-flow

    NASA Astrophysics Data System (ADS)

    Isaac, K. M.; Schetz, J. A.

    1982-12-01

    The analysis of Campbell and Schetz (1973) is extended to the study of multiple jets in a cross flow, where the interaction of two jets is taken into account by a modification of the drag coefficient that is sensed by each jet. Results show that the rear jet trajectory is significantly modified by the presence of the front one even when the jets are spaced far apart. The analysis is applicable to such phenomena as the exhaust of chimney stack smoke into a wind and the lift jets of a V/STOL aircraft during takeoff or landing in strong winds.

  4. Preparing cytotoxic agents in an isolator.

    PubMed

    Favier, M; Hansel, S; Bressolle, F

    1993-11-01

    The design of an isolator and its use by an oncology satellite pharmacy for preparing cytotoxic drugs are described. The isolator (Iso Concept, Boulogne, France) is a totally enclosed ventilated biological-safety cabinet of class III polyvinyl chloride (PVC) with positive air pressure, a half-suit with a rotating seal, and attached neoprene gloves. There are three work-stations, one for the half-suit and two along one side of the isolator. The ventilation and air filtration system consists of one entry pipe with a full ventilation-filtration box fitted with one prefilter, one blower, one ball valve, one high-efficiency particulate air (HEPA) filter, one airtight nipple connected to an automatic sterilizer, alarms, and one exhaust pipe protected by a HEPA filter. The air lock consists of a rigid, transparent Plexiglas pass-through. The chamber is sterilized with heated compressed air mixed with 3.5% peracetic acid. Maintenance includes regular changing of gloves and HEPA filters; checking of the integrity of the PVC, half-suit, and gloves; and washing and decontamination procedures. Preparation of cytotoxics is planned in advance with prescription data and manufacturing sheets. In the half-suit, a pharmacy technician reads the label, supervises preparation of the sterile admixture, and writes a label. The operators on the side of the unit read the manufacturing sheet and prepare the dose identified by the label.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Cooking-related PM2.5 and acrolein measured in grocery stores and comparison with other retail types.

    PubMed

    Chan, W R; Sidheswaran, M; Sullivan, D P; Cohn, S; Fisk, W J

    2016-06-01

    We measured particulate matter (PM), acrolein, and other indoor air contaminants in eight visits to grocery stores in California. Retail stores of other types (hardware, furniture, and apparel) were also sampled on additional visits. Based on tracer gas decay data, most stores had adequate ventilation according to minimum ventilation rate standards. Grocery stores had significantly higher concentrations of acrolein, fine and ultrafine PM, compared to other retail stores, likely attributable to cooking. Indoor concentrations of PM2.5 and acrolein exceeded health guidelines in all tested grocery stores. Acrolein emission rates to indoors in grocery stores had a mean estimate about 30 times higher than in other retail store types. About 80% of the indoor PM2.5 measured in grocery stores was emitted indoors, compared to only 20% for the other retail store types. Calculations suggest a substantial increase in outdoor air ventilation rate by a factor of three from current level is needed to reduce indoor acrolein concentrations. Alternatively, acrolein emission to indoors needs to be reduced 70% by better capturing of cooking exhaust. To maintain indoor PM2.5 below the California annual ambient standard of 12 μg/m(3) , grocery stores need to use air filters with an efficiency rating higher than the MERV 8 air filters commonly used today. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Transport characteristics of expiratory droplets and droplet nuclei in indoor environments with different ventilation airflow patterns.

    PubMed

    Wan, M P; Chao, C Y H

    2007-06-01

    Expiratory droplets and droplet nuclei can be pathogen carriers for airborne diseases. Their transport characteristics were studied in detail in two idealized floor-supply-type ventilation flow patterns: Unidirectional-upward and single-side-floor, using a multiphase numerical model. The model was validated by running interferometric Mie imaging experiments using test droplets with nonvolatile content, which formed droplet nuclei, ultimately, in a class-100 clean-room chamber. By comparing the droplet dispersion and removal characteristics with data of two other ceiling-supply ventilation systems collected from a previous work, deviations from the perfectly mixed ventilation condition were found to exist in various cases to different extent. The unidirectional-upward system was found to be more efficient in removing the smallest droplet nuclei (formed from 1.5 mum droplets) by air extraction, but it became less effective for larger droplets and droplet nuclei. Instead, the single-side-floor system was shown to be more favorable in removing these large droplets and droplet nuclei. In the single-side-floor system, the lateral overall dispersion coefficients for the small droplets and nuclei (initial size

  7. Surgical smoke control with local exhaust ventilation: Experimental study.

    PubMed

    Lee, Taekhee; Soo, Jhy-Charm; LeBouf, Ryan F; Burns, Dru; Schwegler-Berry, Diane; Kashon, Michael; Bowers, Jay; Harper, Martin

    2018-04-01

    This experimental study aimed to evaluate airborne particulates and volatile organic compounds (VOCs) from surgical smoke when a local exhaust ventilation (LEV) system is in place. Surgical smoke was generated from human tissue in an unoccupied operating room using an electrocautery surgical device for 15 min with 3 different test settings: (1) without LEV control; (2) control with a wall irrigation suction unit with an in-line ultra-low penetration air filter; and (3) control with a smoke evacuation system. Flow rate of LEVs was approximately 35 L/min and suction was maintained within 5 cm of electrocautery interaction site. A total of 6 experiments were conducted. Particle number and mass concentrations were measured using direct reading instruments including a condensation particle counter (CPC), a light-scattering laser photometer (DustTrak DRX), a scanning mobility particle sizer (SMPS), an aerodynamic particle sizer (APS), and a viable particle counter. Selected VOCs were collected using evacuated canisters using grab, personal and area sampling techniques. The largest average particle and VOCs concentrations were found in the absence of LEV control followed by LEV controls. Average ratios of LEV controls to without LEV control ranged 0.24-0.33 (CPC), 0.28-0.39 (SMPS), 0.14-0.31 (DustTrak DRX), and 0.26-0.55 (APS). Ethanol and isopropyl alcohol were dominant in the canister samples. Acetaldehyde, acetone, acetonitrile, benzene, hexane, styrene, and toluene were detected but at lower concentrations (<500 μg/m 3 ) and concentrations of the VOCs were much less than the National Institute for Occupational Safety and Health recommended exposure limit values. Utilization of the LEVs for surgical smoke control can significantly reduce but not completely eliminate airborne particles and VOCs.

  8. Evaluation of a Dust Control for a Small Slab-Riding Dowel Drill for Concrete Pavement

    PubMed Central

    Echt, Alan; Mead, Kenneth

    2016-01-01

    Purpose To assess the effectiveness of local exhaust ventilation to control respirable crystalline silica exposures to acceptable levels during concrete dowel drilling. Approach Personal breathing zone samples for respirable dust and crystalline silica were collected while laborers drilled holes 3.5 cm diameter by 36 cm deep in a concrete slab using a single-drill slab-riding dowel drill equipped with local exhaust ventilation. Data were collected on air flow, weather, and productivity. Results All respirable dust samples were below the 90 µg detection limit which, when combined with the largest sample volume, resulted in a minimum detectable concentration of 0.31 mg m−3. This occurred in a 32-min sample collected when 27 holes were drilled. Quartz was only detected in one air sample; 0.09 mg m−3 of quartz was found on an 8-min sample collected during a drill maintenance task. The minimum detectable concentration for quartz in personal air samples collected while drilling was performed was 0.02 mg m−3. The average number of holes drilled during each drilling sample was 23. Over the course of the 2-day study, air flow measured at the dust collector decreased from 2.2 to 1.7 m3 s−1. Conclusions The dust control performed well under the conditions of this test. The initial duct velocity with a clean filter was sufficient to prevent settling, but gradually fell below the recommended value to prevent dust from settling in the duct. The practice of raising the drill between each hole may have prevented the dust from settling in the duct. A slightly higher flow rate and an improved duct design would prevent settling without regard to the position of the drill. PMID:26826033

  9. Nano-metal oxides: Exposure and engineering control assessment.

    PubMed

    Garcia, Alberto; Eastlake, Adrienne; Topmiller, Jennifer L; Sparks, Christopher; Martinez, Kenneth; Geraci, Charles L

    2017-09-01

    In January 2007, the National Institute for Occupational Safety and Health (NIOSH) conducted a field study to evaluate process specific emissions during the production of ENMs. This study was performed using the nanoparticle emission assessment technique (NEAT). During this study, it was determined that ENMs were released during production and cleaning of the process reactor. Airborne concentrations of silver, nickel, and iron were found both in the employee's personal breathing zone and area samples during reactor cleaning. At the completion of this initial survey, it was suggested that a flanged attachment be added to the local exhaust ventilation system.  NIOSH re-evaluated the facility in December 2011 to assess worker exposures following an increase in production rates. This study included a fully comprehensive emissions, exposure, and engineering control evaluation of the entire process. This study made use of the nanoparticle exposure assessment technique (NEAT 2.0). Data obtained from filter-based samples and direct reading instruments indicate that reactor cleanout increased the overall particle concentration in the immediate area. However, it does not appear that these concentrations affect areas outside of the production floor. As the distance between the reactor and the sample location increased, the observed particle number concentration decreased, creating a concentration gradient with respect to the reactor. The results of this study confirm that the flanged attachment on the local exhaust ventilation system served to decrease exposure potential.  Given the available toxicological data of the metals evaluated, caution is warranted. One should always keep in mind that occupational exposure levels were not developed specifically for nanoscale particles. With data suggesting that certain nanoparticles may be more toxic than the larger counterparts of the same material; employers should attempt to control emissions of these particles at the source, to limit the potential for exposure.

  10. Reduction in welding fume and metal exposure of stainless steel welders: an example from the WELDOX study.

    PubMed

    Lehnert, Martin; Weiss, Tobias; Pesch, Beate; Lotz, Anne; Zilch-Schöneweis, Sandra; Heinze, Evelyn; Van Gelder, Rainer; Hahn, Jens-Uwe; Brüning, Thomas

    2014-07-01

    In a plant where flux-cored arc welding was applied to stainless steel, we investigated changes in airborne and internal metal exposure following improvements of exhaust ventilation and respiratory protection. Twelve welders were examined at a time in 2008 and in 2011 after improving health protection. Seven welders were enrolled in both surveys. Exposure measurement was performed by personal sampling of respirable welding fume inside the welding helmets during one work shift. Urine and blood samples were taken after the shift. Chromium (Cr), nickel (Ni), and manganese (Mn) were determined in air and biological samples. The geometric mean of respirable particles could be reduced from 4.1 mg/m(3) in 2008-0.5 mg/m(3) in 2011. Exposure to airborne metal compounds was also strongly reduced (Mn: 399 vs. 6.8 μg/m(3); Cr: 187 vs. 6.3 μg/m(3); Ni: 76 vs. 2.8 μg/m(3)), with the most striking reduction inside helmets with purified air supply. Area sampling revealed several concentrations above established or proposed exposure limits. Urinary metal concentrations were also reduced, but to a lesser extent (Cr: 14.8 vs. 4.5 μg/L; Ni: 7.9 vs. 3.1 μg/L). Although biologically regulated, the mean Mn concentration in blood declined from 12.8 to 8.9 μg/L. This intervention study demonstrated a distinct reduction in the exposure of welders using improved exhaust ventilation and welding helmets with purified air supply in the daily routine. Data from area sampling and biomonitoring indicated that the area background level may add considerably to the internal exposure.

  11. Evaluation of a Dust Control for a Small Slab-Riding Dowel Drill for Concrete Pavement.

    PubMed

    Echt, Alan; Mead, Kenneth

    2016-05-01

    To assess the effectiveness of local exhaust ventilation to control respirable crystalline silica exposures to acceptable levels during concrete dowel drilling. Personal breathing zone samples for respirable dust and crystalline silica were collected while laborers drilled holes 3.5 cm diameter by 36 cm deep in a concrete slab using a single-drill slab-riding dowel drill equipped with local exhaust ventilation. Data were collected on air flow, weather, and productivity. All respirable dust samples were below the 90 µg detection limit which, when combined with the largest sample volume, resulted in a minimum detectable concentration of 0.31 mg m(-3). This occurred in a 32-min sample collected when 27 holes were drilled. Quartz was only detected in one air sample; 0.09 mg m(-3) of quartz was found on an 8-min sample collected during a drill maintenance task. The minimum detectable concentration for quartz in personal air samples collected while drilling was performed was 0.02 mg m(-3). The average number of holes drilled during each drilling sample was 23. Over the course of the 2-day study, air flow measured at the dust collector decreased from 2.2 to 1.7 m(3) s(-1). The dust control performed well under the conditions of this test. The initial duct velocity with a clean filter was sufficient to prevent settling, but gradually fell below the recommended value to prevent dust from settling in the duct. The practice of raising the drill between each hole may have prevented the dust from settling in the duct. A slightly higher flow rate and an improved duct design would prevent settling without regard to the position of the drill. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2016.

  12. [Comparison of perforated metal ceiling systems (supported airflow ceilings) with laminar airflow ceilings in type A (DIN 1946 T.4) operating rooms under surgical conditions].

    PubMed

    Bischoff, W E; Kindermann, A; Sander, U; Sander, J

    1995-10-01

    In eleven centrally ventilated operating theatres the concentration of particles and airborne germs in wound vicinity was measured on three workdays. Five theatres were equipped with air supply ceilings with supporting flow outlets (supporting flow ceilings), five with laminar air flow ceilings and one with an air supply ceiling, a body exhaust system and a partition wall between the anesthetic and operating areas. Under routine conditions the air supply of the laminar air flow ceiling with its lower turbulence shielded the operating field from the largely staff-related air contamination in the rest of the theatre better than in the case of the supporting flow ceilings. Particles and airborne germs were removed from the endangered wound area faster. A spatial separation between the anesthetic and the operating areas as well as a body exhaust system lead to a considerable reduction of the contamination. Two theatres were conspicuous by reason of their considerably raised values due to defective control engineering and the wrongly positioning of the operating table. From the point of view of ventilation technique the laminar air flow ceilings with lower turbulence are superior to air supply ceilings with supporting flow outlets in the working day of an operating theatre. In order to minimize the influence of the staff, which up till now has been neglected in testing specifications, constructional possibilities such as the size of ceiling, the partitioning off of operating and anaesthetic areas and the positioning of the operating table in relation to the incoming air should be coordinated rationally. Taking measurements regularly during operations can provide the impulse for considerable improvements in both operational and planning phases.

  13. Determinants of wood dust exposure in the Danish furniture industry.

    PubMed

    Mikkelsen, Anders B; Schlunssen, Vivi; Sigsgaard, Torben; Schaumburg, Inger

    2002-11-01

    This paper investigates the relation between wood dust exposure in the furniture industry and occupational hygiene variables. During the winter 1997-98 54 factories were visited and 2362 personal, passive inhalable dust samples were obtained; the geometric mean was 0.95 mg/m(3) and the geometric standard deviation was 2.08. In a first measuring round 1685 dust concentrations were obtained. For some of the workers repeated measurements were carried out 1 (351) and 2 weeks (326) after the first measurement. Hygiene variables like job, exhaust ventilation, cleaning procedures, etc., were documented. A multivariate analysis based on mixed effects models was used with hygiene variables being fixed effects and worker, machine, department and factory being random effects. A modified stepwise strategy of model making was adopted taking into account the hierarchically structured variables and making possible the exclusion of non-influential random as well as fixed effects. For woodworking, the following determinants of exposure increase the dust concentration: manual and automatic sanding and use of compressed air with fully automatic and semi-automatic machines and for cleaning of work pieces. Decreased dust exposure resulted from the use of compressed air with manual machines, working at fully automatic or semi-automatic machines, functioning exhaust ventilation, work on the night shift, daily cleaning of rooms, cleaning of work pieces with a brush, vacuum cleaning of machines, supplementary fresh air intake and safety representative elected within the last 2 yr. For handling and assembling, increased exposure results from work at automatic machines and presence of wood dust on the workpieces. Work on the evening shift, supplementary fresh air intake, work in a chair factory and special cleaning staff produced decreased exposure to wood dust. The implications of the results for the prevention of wood dust exposure are discussed.

  14. Effects of air ventilation during stationary exercise testing.

    PubMed

    Van Schuylenbergh, R; Vanden Eynde, B; Hespel, P

    2004-07-01

    The impact of air ventilation on performance and physiological responses during stationary exercise in the laboratory was studied. Fourteen well-trained cyclists performed three exercise tests on a cycle ergometer, each separated by a 1-week interval. The first test was a graded test to determine the power output corresponding with the 4-mmol l(-1) lactate level. Tests 2 and 3 were 30-min constant-load tests at a power output corresponding with this 4-mmol l(-1) lactate threshold. One constant-load test was performed in the absence (NAV), whilst the other was performed in the presence (AV) of air ventilation (3 m s(-1)). During the constant-load tests, heart rate, tympanic temperature, blood lactate concentration and oxygen uptake (VO2) were measured at 10-min intervals and at the end of the test. Differences between the two test conditions were evaluated using paired t-tests. During NAV, 12 subjects interrupted the test due to premature exhaustion (exercise duration <30 min), versus only seven in AV ( P<0.05). At the end of the test tympanic temperature was 35.9 (0.2) degrees C in AV and was higher in NAV [36.7 (0.2) degrees C, P<0.05]. Exercise heart rate increased at a faster rate during NAV [+2.2 (0.3) beats min(-1)] than during AV [+1.5 (0.2) beats min(-1), P<0.05]. Blood lactate concentration and VO2 were similar between conditions. Air ventilation is essential to prevent an upward shift in the lactate:heart rate as well as the power output:heart rate relationship during laboratory exercise testing and indoor exercise training.

  15. Final Technical Report: Affordable, High-Performance, Intermediate Temperature Solid Oxide Fuel Cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blackburn, Bryan M.; Bishop, Sean; Gore, Colin

    In this project, we improved the power output and voltage efficiency of our intermediate temperature solid oxide fuel cells (IT-SOFCs) with a focus on ~600 °C operation. At these temperatures and with the increased power density (i.e., fewer cells for same power output), the stack cost should be greatly reduced while extending durability. Most SOFC stacks operate at temperatures greater than 800 °C. This can greatly increase the cost of the system (stacks and BOP) as well as maintenance costs since the most common degradation mechanisms are thermally driven. Our approach uses no platinum group metal (PGM) materials and themore » lower operating temperature allows use of simple stainless steel interconnects and commercial off-the-shelf gaskets in the stack. Furthermore, for combined heating and power (CHP) applications the stack exhaust still provides “high quality” waste heat that can be recovered and used in a chiller or boiler. The anticipated performance, durability, and resulting cost improvements (< $700/kWe) will also move us closer to reaching the full potential of this technology for distributed generation (DG) and residential/commercial CHP. This includes eventual extension to cleaner, more efficient portable generators, auxiliary power units (APUs), and range extenders for transportation. The research added to the understanding of the area investigated by exploring various methods for increasing power density (Watts/square centimeter of active area in each cell) and increasing cell efficiency (increasing the open circuit voltage, or cell voltage with zero external electrical current). The results from this work demonstrated an optimized cell that had greater than 1 W/cm2 at 600 °C and greater than 1.6 W/cm2 at 650 °C. This was demonstrated in large format sizes using both 5 cm by 5 cm and 10 cm by 10 cm cells. Furthermore, this work demonstrated that high stability (no degradation over > 500 hours) can be achieved together with high performance in large format cells as large as 10 cm by 10 cm when operated at ~600 °C. The project culminated in the demonstration of a 12-cell stack using the porous anode-based SOFC technology.« less

  16. Lung Function and Incidence of Chronic Obstructive Pulmonary Disease after Improved Cooking Fuels and Kitchen Ventilation: A 9-Year Prospective Cohort Study

    PubMed Central

    Zhou, Yumin; Zou, Yimin; Li, Xiaochen; Chen, Shuyun; Zhao, Zhuxiang; He, Fang; Zou, Weifeng; Luo, Qiuping; Li, Wenxi; Pan, Yiling; Deng, Xiaoliang; Wang, Xiaoping; Qiu, Rong; Liu, Shiliang; Zheng, Jingping; Zhong, Nanshan; Ran, Pixin

    2014-01-01

    Background Biomass smoke is associated with the risk of chronic obstructive pulmonary disease (COPD), but few studies have elaborated approaches to reduce the risk of COPD from biomass burning. The purpose of this study was to determine whether improved cooking fuels and ventilation have effects on pulmonary function and the incidence of COPD. Methods and Findings A 9-y prospective cohort study was conducted among 996 eligible participants aged at least 40 y from November 1, 2002, through November 30, 2011, in 12 villages in southern China. Interventions were implemented starting in 2002 to improve kitchen ventilation (by providing support and instruction for improving biomass stoves or installing exhaust fans) and to promote the use of clean fuels (i.e., biogas) instead of biomass for cooking (by providing support and instruction for installing household biogas digesters); questionnaire interviews and spirometry tests were performed in 2005, 2008, and 2011. That the interventions improved air quality was confirmed via measurements of indoor air pollutants (i.e., SO2, CO, CO2, NO2, and particulate matter with an aerodynamic diameter of 10 µm or less) in a randomly selected subset of the participants' homes. Annual declines in lung function and COPD incidence were compared between those who took up one, both, or neither of the interventions. Use of clean fuels and improved ventilation were associated with a reduced decline in forced expiratory volume in 1 s (FEV1): decline in FEV1 was reduced by 12 ml/y (95% CI, 4 to 20 ml/y) and 13 ml/y (95% CI, 4 to 23 ml/y) in those who used clean fuels and improved ventilation, respectively, compared to those who took up neither intervention, after adjustment for confounders. The combined improvements of use of clean fuels and improved ventilation had the greatest favorable effects on the decline in FEV1, with a slowing of 16 ml/y (95% CI, 9 to 23 ml/y). The longer the duration of improved fuel use and ventilation, the greater the benefits in slowing the decline of FEV1 (p<0.05). The reduction in the risk of COPD was unequivocal after the fuel and ventilation improvements, with an odds ratio of 0.28 (95% CI, 0.11 to 0.73) for both improvements. Conclusions Replacing biomass with biogas for cooking and improving kitchen ventilation are associated with a reduced decline in FEV1 and risk of COPD. Trial Registration Chinese Clinical Trial Register ChiCTR-OCH-12002398 Please see later in the article for the Editors' Summary PMID:24667834

  17. Decommissioning of Active Ventilation Systems in a Nuclear R and D Facility to Prepare for Building Demolition (Whiteshell Laboratories Decommissioning Project, Canada) - 13073

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilcox, Brian; May, Doug; Howlett, Don

    2013-07-01

    Whiteshell Laboratories (WL) is a nuclear research establishment owned by the Canadian government and operated by Atomic Energy of Canada Limited (AECL) since the early 1960's. WL is currently under a decommissioning license and the mandate is to remediate the nuclear legacy liabilities in a safe and cost effective manner. The WL Project is the first major nuclear decommissioning project in Canada. A major initiative underway is to decommission and demolish the main R and D Laboratory complex. The Building 300 R and D complex was constructed to accommodate laboratories and offices which were mainly used for research and developmentmore » associated with organic-cooled reactors, nuclear fuel waste management, reactor safety, advanced fuel cycles and other applications of nuclear energy. Building 300 is a three storey structure of approximately 16,000 m{sup 2}. In order to proceed with building demolition, the contaminated systems inside the building have to be characterized, removed, and the waste managed. There is a significant focus on volume reduction of radioactive waste for the WL project. The active ventilation system is one of the significant contaminated systems in Building 300 that requires decommissioning and removal. The active ventilation system was designed to manage hazardous fumes and radioactivity from ventilation devices (e.g., fume hoods, snorkels and glove boxes) and to prevent the escape of airborne hazardous material outside of the laboratory boundary in the event of an upset condition. The system includes over 200 ventilation devices and 32 active exhaust fan units and high efficiency particulate air (HEPA) filters. The strategy to remove the ventilation system was to work from the laboratory end back to the fan/filter system. Each ventilation duct was radiologically characterized. Fogging was used to minimize loose contamination. Sections of the duct were removed by various cutting methods and bagged for temporary storage prior to disposition. Maintenance of building heating, ventilation and air conditioning (HVAC) balancing was critical to ensure proper airflow and worker safety. Approximately 103 m{sup 3} of equipment and materials were recovered or generated by the project. Low level waste accounted for approximately 37.4 m{sup 3}. Where possible, ducting was free released for metal recycling. Contaminated ducts were compacted into B-1000 containers and stored in a Shielded Modular Above-Ground Storage Facility (SMAGS) on the WL site awaiting final disposition. The project is divided into three significant phases, with Phases 1 and 2 completed. Lessons learned during the execution of Phases 1 and 2 have been incorporated into the current ventilation removal. (authors)« less

  18. Diesel oil pool fire characteristic under natural ventilation conditions in tunnels with roof openings.

    PubMed

    Wang, Yanfu; Jiang, Juncheng; Zhu, Dezhi

    2009-07-15

    In order to research the fire characteristic under natural ventilation conditions in tunnels with roof openings, full-scale experiment of tunnel fire is designed and conducted. All the experimental data presented in this paper can be further applied for validation of numerical simulation models and reduced-scale experimental results. The physical model of tunnel with roof openings and the mathematical model of tunnel fire are presented in this paper. The tunnel fire under the same conditions as experiment is simulated using CFD software. From the results, it can be seen that most smoke is discharged directly off the tunnel through roof openings, so roof openings are favorable for exhausting smoke. But along with the decrease of smoke temperatures, some smoke may backflow and mix with the smoke-free layer below, which leads to fall in visibility and is unfavorable for personnel evacuation. So it is necessary to research more efficient ways for improving the smoke removal efficiency, such as early fire detection systems, adequate warning signs and setting tunnel cap.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniels, W.J.; Donohue, M.T.; Singal, M.

    Environmental and brathing zone samples were analyzed for di(2-ethylhexyl)adipate, hydrogen-chloride, cyclohexanol, dicyclohexyl-phthalate, phthalic-anhydride, and total particulates at Ashland Super Valu, Ashland, Wisconsin in June, 1984. The evaluation was requested by a company representative due to complaints of respiratory problems by one of the meat department employees. Four meat department employees were interviewed. The authors conclude that it is not possible to determine whether or not the symptoms reported by the meat packer are due to emissions from heated meat wrap or label adhesive. Recommendations included not operating the cool rod cutter at a temperature above 280 degrees-F and installing localmore » exhaust ventilation.« less

  20. Activated charcoal filters: Water treatment, pollution control, and industrial applications. (Latest citations from the Patent Bibliographic database with exemplary claims. ) Published Search

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The bibliography contains citations of selected patents concerning activated charcoal filters and their applications in water treatment, pollution control, and industrial processes. Filtering methods and equipment for air and water purification, industrial distillation and extraction, industrial leaching, and filtration of toxic materials and contaminants are described. Applications include drinking water purification, filtering beverages, production of polymer materials, solvent and metal recovery, waste conversion, automotive fuel and exhaust systems, swimming pool filtration, tobacco smoke filters, kitchen ventilators, medical filtration treatment, and odor absorbing materials. (Contains 250 citations and includes a subject term index and title list.)

  1. Operating Room Environment Control. Part A: a Valve Cannister System for Anesthetic Gas Adsorption. Part B: a State-of-the-art Survey of Laminar Flow Operating Rooms. Part C: Three Laminar Flow Experiments

    NASA Technical Reports Server (NTRS)

    Meyer, J. S.; Kosovich, J.

    1973-01-01

    An anesthetic gas flow pop-off valve canister is described that is airtight and permits the patient to breath freely. Once its release mechanism is activated, the exhaust gases are collected at a hose adapter and passed through activated coal for adsorption. A survey of laminar air flow clean rooms is presented and the installation of laminar cross flow air systems in operating rooms is recommended. Laminar flow ventilation experiments determine drying period evaporation rates for chicken intestines, sponges, and sections of pig stomach.

  2. Reliability of time-to-exhaustion and selected psycho-physiological variables during constant-load cycling at the maximal lactate steady-state.

    PubMed

    Faude, Oliver; Hecksteden, Anne; Hammes, Daniel; Schumacher, Franck; Besenius, Eric; Sperlich, Billy; Meyer, Tim

    2017-02-01

    The maximal lactate steady-state (MLSS) is frequently assessed for prescribing endurance exercise intensity. Knowledge of the intra-individual variability of the MLSS is important for practical application. To date, little is known about the reliability of time-to-exhaustion and physiological responses to exercise at MLSS. Twenty-one healthy men (age, 25.2 (SD 3.3) years; height, 1.83 (0.06) m; body mass, 78.9 (8.9) kg; maximal oxygen uptake, 57.1 (10.7) mL·min -1 ·kg -1 ) performed 1 incremental exercise test, and 2 constant-load tests to determine MLSS intensity. Subsequently, 2 open-end constant-load tests (MLSS 1 and 2) at MLSS intensity (3.0 (0.7) W·kg -1 , 76% (10%) maximal oxygen uptake) were carried out. During the tests, blood lactate concentrations, heart rate, ratings of perceived exertion (RPE), variables of gas exchange, and core body temperature were determined. Time-to-exhaustion was 50.8 (14.0) and 48.2 (16.7) min in MLSS 1 and 2 (mean change: -2.6 (95% confidence interval: -7.8, 2.6)), respectively. The coefficient of variation (CV) was high for time-to-exhaustion (24.6%) and for mean (4.8 (1.2) mmol·L -1 ) and end (5.4 (1.7) mmol·L -1 ) blood lactate concentrations (15.7% and 19.3%). The CV of mean exercise values for all other parameters ranged from 1.4% (core temperature) to 8.3% (ventilation). At termination, the CVs ranged from 0.8% (RPE) to 11.8% (breathing frequency). The low reliability of time-to-exhaustion and blood lactate concentration at MLSS indicates that the precise individual intensity prescription may be challenging. Moreover, the obtained data may serve as reference to allow for the separation of intervention effects from random variation in our sample.

  3. A review on waste heat recovery from exhaust in the ceramics industry

    NASA Astrophysics Data System (ADS)

    Delpech, Bertrand; Axcell, Brian; Jouhara, Hussam

    2017-11-01

    Following the energy crisis in 1980, many saving technologies have been investigated with attempts to implement them into various industries, one of them is the field of ceramic production. In order to comply with energy saving trends and environmental issues, the European ceramic industry sector has developed energy efficient systems which reduced significantly production time and costs and reduced total energy consumption. The last achievement is of great importance as the energy consumption of the ceramic process accounts for a significant percentage of the total production costs. More precisely, the firing stage consumes the highest amount of energy during the whole ceramic production process. The use of roller kilns, fired by natural gas, involves a loss of 50% of the input energy via the flue gas and the cooling gas exhausts. This review paper briefly describes the production process of the different ceramic products, with a focus on the ceramic sector in Europe. Due to the limited on waste heat recovery in the ceramic industry, other high temperature waste heat recovery applications are considered in the paper, such as in concrete and steel production, which could have a potential use in the ceramic industry. The state of the art technologies used in the ceramics industry are reviewed with a special interest in waste heat recovery from the ceramic process exhaust stacks and energy saving technologies.

  4. Changes in sevoflurane plasma concentration with delivery through the oxygenator during on-pump cardiac surgery.

    PubMed

    Nitzschke, R; Wilgusch, J; Kersten, J F; Trepte, C J; Haas, S A; Reuter, D A; Goetz, A E; Goepfert, M S

    2013-06-01

    It is unclear what factors affect the uptake of sevoflurane administered through the membrane oxygenator during cardiopulmonary bypass (CPB) and whether this can be monitored via the oxygenator exhaust gas. Stable delivery of sevoflurane was administered to 30 elective cardiac surgery patients at 1.8 vol% (inspiratory) via the anaesthetic circuit and ventilator. During CPB, sevoflurane was administered in the oxygenator fresh gas supply (Compactflo Evolution™; Sorin Group, Milano, Italy). Sevoflurane plasma concentration (SPC) was measured using gas chromatography. Changes were correlated with bispectral index (BIS), patient temperature, haematocrit, plasma albumin concentration, oxygenator fresh gas flow, and the sevoflurane concentration in the oxygenator exhaust at predefined time points. The mean SPC pre-bypass was 54.9 µg ml(-1) [95% confidence interval (CI): 50.6-59.1]. SPC decreased to 43.2 µg ml(-1) (95% CI: 40.3-46.1; P<0.001) after initiation of CPB, and was lower still during rewarming and weaning from bypass, 39.4 µg ml(-1) (95% CI: 36.6-42.3; P<0.001). BIS did not exceed a value of 55. SPCs were higher during hypothermia (P<0.001) and with an increase in oxygenator fresh gas flow (P=0.015), and lower with haemodilution (P=0.027). No correlation was found between SPC and the concentration of sevoflurane in the oxygenator exhaust gas (r=-0.04; 95% CI: -0.18 to 0.09; P=0.53). The uptake of sevoflurane delivered via the membrane oxygenator during CPB seems to be affected by hypothermia, haemodilution, and changes in the oxygenator fresh gas supply flow. Measuring the concentration of sevoflurane in the exhaust from the oxygenator is not useful for monitoring sevoflurane administration during bypass.

  5. Hourly elemental concentrations in PM2.5 aerosols sampled simultaneously at urban background and road site during SAPUSS - diurnal variations and PMF receptor modelling

    NASA Astrophysics Data System (ADS)

    Dall'Osto, M.; Querol, X.; Amato, F.; Karanasiou, A.; Lucarelli, F.; Nava, S.; Calzolai, G.; Chiari, M.

    2013-04-01

    Hourly-resolved aerosol chemical speciation data can be a highly powerful tool to determine the source origin of atmospheric pollutants in urban environments. Aerosol mass concentrations of seventeen elements (Na, Mg, Al, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Sr and Pb) were obtained by time (1 h) and size (PM2.5 particulate matter < 2.5 μm) resolved aerosol samples analysed by Particle Induced X-ray Emission (PIXE) measurements. In the Marie Curie European Union framework of SAPUSS (Solving Aerosol Problems by Using Synergistic Strategies), the approach used is the simultaneous sampling at two monitoring sites in Barcelona (Spain) during September-October 2010: an urban background site (UB) and a street canyon traffic road site (RS). Elements related to primary non-exhaust traffic emission (Fe, Cu), dust resuspension (Ca) and anthropogenic Cl were found enhanced at the RS, whereas industrial related trace metals (Zn, Pb, Mn) were found at higher concentrations at the more ventilated UB site. When receptor modelling was performed with positive matrix factorization (PMF), nine different aerosol sources were identified at both sites: three types of regional aerosols (regional sulphate (S) - 27%, biomass burning (K) - 5%, sea salt (Na-Mg) - 17%), three types of dust aerosols (soil dust (Al-Ti) - 17%, urban crustal dust (Ca) - 6%, and primary traffic non-exhaust brake dust (Fe-Cu) - 7%), and three types of industrial aerosol plumes-like events (shipping oil combustion (V-Ni) - 17%, industrial smelters (Zn-Mn) - 3%, and industrial combustion (Pb-Cl) - 5%, percentages presented are average source contributions to the total elemental mass measured). The validity of the PMF solution of the PIXE data is supported by very good correlations with external single particle mass spectrometry measurements. Some important conclusions can be drawn about the PM2.5 mass fraction simultaneously measured at the UB and RS sites: (1) the regional aerosol sources impact both monitoring sites at similar concentrations regardless their different ventilation conditions; (2) by contrast, local industrial aerosol plumes associated with shipping oil combustion and smelters activities have a higher impact on the more ventilated UB site; (3) a unique source of Pb-Cl (associated with combustion emissions) is found to be the major (82%) source of fine Cl in the urban agglomerate; (4) the mean diurnal variation of PM2.5 primary traffic non-exhaust brake dust (Fe-Cu) suggests that this source is mainly emitted and not resuspended, whereas PM2.5 urban dust (Ca) is found mainly resuspended by both traffic vortex and sea breeze; (5) urban dust (Ca) is found the aerosol source most affected by land wetness, reduced by a factor of eight during rainy days and suggesting that wet roads may be a solution for reducing urban dust concentrations.

  6. Methane and nitrous oxide analyzer comparison and emissions from dairy freestall barns with manure flushing and scraping

    NASA Astrophysics Data System (ADS)

    Cortus, Erin L.; Jacobson, Larry D.; Hetchler, Brian P.; Heber, Albert J.; Bogan, Bill W.

    2015-01-01

    Continuous methane (CH4) and nitrous oxide (N2O) emission measurements were conducted at two crossflow-ventilated dairy freestall barns located in the state of Wisconsin, USA during a 19-month period from 2008 to 2010. The two cross-flow mechanically ventilated buildings (275 and 375 cow capacities) were evaluated in the National Air Emissions Monitoring Study. In September of 2008, the barns' manure collection systems were changed from flushing open gutter using manure basin effluent to a tractor scrape. A photoacoustic multi-gas analyzer (PAMGA) and a direct methane/non-methane hydrocarbon analyzer (GC-FID) provided side-by-side measurements of methane (CH4) for 13 months. The PAMGA also measured nitrous oxide (N2O), and a side-by-side comparison was performed with a gas-filter correlation analyzer (GFC) for six months. Barn ventilation rates were measured by recording run times of the 127-cm diameter exhaust fans. All 125 belt-driven exhaust fans were identical, and in situ airflow measurements using the Fan Assessment Numeration System (FANS) were conducted once at the beginning and twice during the test. Daily CH4 and N2O emission rates were calculated over approximately 19 and 6 month periods respectively, on per barn, head, animal unit, floor area space and barn capacity bases. The differences between the analyzers' concentration measurements were compared in conjunction with water vapor and other gases. The analyzer type had a significant impact on the average CH4 emission rate (p < 0.001) and the average N2O emission rate (p < 0.05). Based on the CH4 measurements with the GC-FID, average daily mean CH4 emissions were approximately 290 g AU-1 d-1 (390 g cow-1 d-1) with very limited seasonal effects. Little variation was observed in CH4 emission rates before and after the change in manure collection method, suggesting that most of the CH4 emissions were enteric losses directly from the cows. The average daily mean N2O emission rates based on the GFC were very low, with an approximate rate of only 690 mg AU-1 d-1 (970 mg cow-1 d-1). The change in manure collection had no apparent effect on N2O emission.

  7. Contactless electric igniter for vehicle to lower exhaust emission and fuel consumption.

    PubMed

    Shen, Chih-Lung; Su, Jye-Chau

    2014-01-01

    An electric igniter for engine/hybrid vehicles is presented. The igniter comprises a flyback converter, a voltage-stacked capacitor, a PIC-based controller, a differential voltage detector, and an ignition coil, of which structure is non-contact type. Since the electric igniter adopts a capacitor to accumulate energy for engine ignition instead of traditional contacttype approach, it enhances the igniting performance of a spark plug effectively. As a result, combustion efficiency is promoted, fuel consumption is saved, and exhaust emission is reduced. The igniter not only is good for fuel efficiency but also can reduce HC and CO emission significantly, which therefore is an environmentally friendly product. The control core of the igniter is implemented on a single chip, which lowers discrete component count, reduces system volume, and increases reliability. In addition, the ignition timing can be programmed so that a timing regulator can be removed from the proposed system, simplifying its structure. To verify the feasibility and functionality of the igniter, key waveforms are measured and real-car experiments are performed as well.

  8. Contactless Electric Igniter for Vehicle to Lower Exhaust Emission and Fuel Consumption

    PubMed Central

    Su, Jye-Chau

    2014-01-01

    An electric igniter for engine/hybrid vehicles is presented. The igniter comprises a flyback converter, a voltage-stacked capacitor, a PIC-based controller, a differential voltage detector, and an ignition coil, of which structure is non-contact type. Since the electric igniter adopts a capacitor to accumulate energy for engine ignition instead of traditional contacttype approach, it enhances the igniting performance of a spark plug effectively. As a result, combustion efficiency is promoted, fuel consumption is saved, and exhaust emission is reduced. The igniter not only is good for fuel efficiency but also can reduce HC and CO emission significantly, which therefore is an environmentally friendly product. The control core of the igniter is implemented on a single chip, which lowers discrete component count, reduces system volume, and increases reliability. In addition, the ignition timing can be programmed so that a timing regulator can be removed from the proposed system, simplifying its structure. To verify the feasibility and functionality of the igniter, key waveforms are measured and real-car experiments are performed as well. PMID:24672372

  9. Technologies and Materials for Recovering Waste Heat in Harsh Environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nimbalkar, Sachin U.; Thekdi, Arvind; Rogers, Benjamin M.

    2014-12-15

    A large amount (7,204 TBtu/year) of energy is used for process heating by the manufacturing sector in the United States (US). This energy is in the form of fuels mostly natural gas with some coal or other fuels and steam generated using fuels such as natural gas, coal, by-product fuels, and some others. Combustion of these fuels results in the release of heat, which is used for process heating, and in the generation of combustion products that are discharged from the heating system. All major US industries use heating equipment such as furnaces, ovens, heaters, kilns, and dryers. The hotmore » exhaust gases from this equipment, after providing the necessary process heat, are discharged into the atmosphere through stacks. This report deals with identification of industries and industrial heating processes in which the exhaust gases are at high temperature (>1200 F), contain all of the types of reactive constituents described, and can be considered as harsh or contaminated. It also identifies specific issues related to WHR for each of these processes or waste heat streams.« less

  10. Kiln emissions and potters' exposures.

    PubMed

    Hirtle, B; Teschke, K; van Netten, C; Brauer, M

    1998-10-01

    Some ten thousand British Columbia potters work in small private studios, cooperative facilities, educational institutions, or recreation centers. There has been considerable concern that this diffuse, largely unregulated activity may involve exposures to unacceptable levels of kiln emissions. Pottery kiln emissions were measured at 50 sites--10 from each of 5 categories: professional studios, recreation centers, elementary schools, secondary schools, and colleges. Area monitoring was done 76 cm from firing kilns and 1.6 m above the floor to assess breathing zone concentrations of nitrogen dioxide, carbon monoxide, sulfur dioxide, fluorides, aldehydes, aluminum, antimony, arsenic, barium, beryllium, boron, cadmium, chromium, cobalt, copper, gold, iron, lead, lithium, magnesium, manganese, mercury, nickel, selenium, silver, vanadium, and zinc. Personal exposures to the same metals were measured at 24 sites. Almost all measured values were well below permissible concentrations for British Columbia work sites and American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit values (TLVs) with the following two exceptions. A single firing duration (495 minute) acrolein measurement adjacent to an electric kiln (0.109 ppm) exceeded these guidelines. One 15-minute sulfur dioxide measurement collected adjacent to a gas kiln (5.7 ppm) exceeded the ACGIH short-term exposure limit. The fact that concentrations in small, ventilated kiln rooms ranked among the highest measured gives rise to concern that unacceptable levels of contamination may exist where small kiln rooms remain unventilated. Custom designed exhaust hoods and industrial heating, ventilating, and air-conditioning systems were the most effective ventilation strategies. Passive diffusion and wall/window fans were least effective.

  11. Stacking and metamorphism of continuous segments of subducted lithosphere in a high-pressure wedge: The example of Alpine Corsica (France)

    NASA Astrophysics Data System (ADS)

    Vitale Brovarone, Alberto; Beyssac, Olivier; Malavieille, Jacques; Molli, Giancarlo; Beltrando, Marco; Compagnoni, Roberto

    2013-01-01

    Alpine Corsica consists of a stack of variably metamorphosed units of continental and Tethys-derived rocks. It represents an excellent example of high-pressure (HP) orogenic belt, such as the Western Alps, exposed over a small and accessible area. Compared to the Western Alps, the geology of Alpine Corsica is poorly unraveled. During the 1970s-80s, based on either lithostratigraphic or metamorphic field observations, various classifications of the belt have been proposed, but these classifications have been rarely matched together. Furthermore, through time, the internal complexity of large domains has been progressively left aside in the frame of large-scale geodynamic reconstructions. As a consequence, major open questions on the internal structure of the belt have remained unsolved. Apart from a few local studies, Alpine Corsica has not benefited of modern developments in petrology and basin research. This feature results in several uncertainties when combining lithostratigraphic and metamorphic patterns and, consequently, in the definition of an exhaustive architecture of the belt. In this paper we provide a review on the geology of Alpine Corsica, paying particular attention to the available lithostratigraphic and metamorphic classifications of the metamorphic terranes. These data are completed by a new and exhaustive metamorphic dataset obtained by means of thermometry based on Raman Spectroscopy of Carbonaceous Material (RSCM). This technique provides reliable insights on the peak temperature of the metamorphic history for CM-bearing metasediments. A detailed metamorphic characterization of metasediments, which have been previously largely ignored due to retrogression or to the lack of diagnostic mineralogy, is thus obtained and fruitfully coupled with the available lithostratigraphic data. Nine main tectono-metamorphic units are defined, from subgreenschist (ca. 280-300 °C) to the lawsonite-eclogite-facies (ca. 500-550 °C) condition. These units are homogeneous in metamorphism, laterally continuous and have characteristic lithostratigraphic features. This study also suggests a direct link between the pre-orogenic extensional setting and the present-day compressional structure of Alpine Corsica, indicating that large sections of subducted lithosphere were subducted and exhumed as coherent domains. These features provide important insight on the mechanism of stacking and exhumation of HP rocks, and make Alpine Corsica a unique reference for mountain-building processes in Tethyan-type orogens.

  12. Forensic aspects of the aerotoxic syndrome.

    PubMed

    Abeyratne, Ruwantissa

    2002-01-01

    Three decades ago, cabin air quality was seemingly not an issue in commercial aviation and the incidence of disease through air borne vectors or toxic fumes was uncommon among passengers and crew. However, it is claimed that modern day jet airliners generally carry the threat of disease through the ventilator systems of these aircraft which are designed for optimum efficiency, leaving them exposed to lapses in the recycling of clean air and blocking fumes from engine exhausts of the jets from entering the inhabited parts of the aircraft. It has been claimed that aerotoxic fumes are most common in the cockpit, and that the technical crew are the most susceptible to the aerotoxic syndrome.

  13. Activated charcoal filters: Water treatment, pollution control, and industrial applications. October 1970-October 1989 (Citations from the US Patent data base). Report for October 1970-October 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This bibliography contains citations of selected patents concerning activated charcoal filters and their applications in water treatment, pollution control, and industrial processes. Filtering methods and equipment for air and water purification, industrial distillation and extraction, industrial leaching, and filtration of toxic materials and contaminants are described. Applications include drinking water purification, filtering beverages, production of polymer materials, solvent and metal recovery, waste conversion, automotive fuel and exhaust systems, swimming-pool filtration, tobacco-smoke filters, kitchen ventilators, medical filtration treatment, and odor-absorbing materials. (This updated bibliography contains 173 citations, 12 of which are new entries to the previous edition.)

  14. Activated-charcoal filters: Water treatment, pollution control, and industrial applications. January 1970-August 1989 (Citations from the US Patent data base). Report for January 1970-August 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This bibliography contains citations of selected patents concerning activated charcoal filters and their applications in water treatment, pollution control, and industrial processes. Filtering methods and equipment for air and water purification, industrial distillation and extraction, industrial leaching, and filtration of toxic materials and contaminants are described. Applications include drinking-water purification, filtering beverages, production of polymer materials, solvent and metal recovery, waste conversion, automotive fuel and exhaust systems, swimming-pool filtration, tobacco-smoke filters, kitchen ventilators, medical-filtration treatment, and odor absorbing materials. (This updated bibliography contains 161 citations, 32 of which are new entries to the previous edition.)

  15. Simulated Altitude Investigation of Stewart-Warner Model 906-B Combustion Heater

    NASA Technical Reports Server (NTRS)

    Ebersbach, Frederick R.; Cervenka, Adolph J.

    1947-01-01

    An investigation has been conducted to determine thermal and pressure-drop performance and the operational characteristics of a Stewart-Warner model 906-B combustion heater. The performance tests covered a range of ventilating-air flows from 500 to 3185 pounds per hour, combustion-air pressure drops from 5 to 35 inches of water, and pressure altitudes from sea level to 41,000 feet. The operational characteristics investigated were the combustion-air flows for sustained combustion and for consistent ignition covering fuel-air ratios ranging from 0.033 to 0.10 and pressure altitudes from sea level to 45,000 feet. Rated heat output of 50,000 Btu per hour was obtained at pressure altitudes up to 27,000 feet for ventilating-air flows greater than 800 pounds per hour; rated output was not obtained at ventilating-air flow below 800 pounds per hour at any altitude. The maximum heater efficiency was found to be 60.7 percent at a fuel-air ratio of 0.050, a sea-level pressure altitude, a ventilating-air temperature of 0 F, combustion-air temperature of 14 F, a ventilating-air flow of 690 pounds per hour, and a combustion-air flow of 72.7 pounds per hour. The minimum combustion-air flow for sustained combustion at a pressure altitude of 25,000 feet was about 9 pounds per hour for fuel-air ratios between 0.037 and 0.099 and at a pressure altitude of 45,000 feet increased to 18 pounds per hour at a fuel-air ratio of 0.099 and 55 pounds per hour at a fuel-air ratio of 0.036. Combustion could be sustained at combustion-air flows above values of practical interest. The maximum flow was limited, however, by excessively high exhaust-gas temperature or high pressure drop. Both maximum and minimum combustion-air flows for consistent ignition decrease with increasing pressure altitude and the two curves intersect at a pressure altitude of approximately 25,000 feet and a combustion-air flow of approximately 28 pounds per hour.

  16. Models for nearly every occasion: Part III - One box decreasing emission models.

    PubMed

    Hewett, Paul; Ganser, Gary H

    2017-11-01

    New one box "well-mixed room" decreasing emission (DE) models are introduced that allow for local exhaust or local exhaust with filtered return, as well the recirculation of a filtered (or cleaned) portion of the general room ventilation. For each control device scenario, a steady state and transient model is presented. The transient equations predict the concentration at any time t after the application of a known mass of a volatile substance to a surface, and can be used to predict the task exposure profile, the average task exposure, as well as peak and short-term exposures. The steady state equations can be used to predict the "average concentration per application" that is reached whenever the substance is repeatedly applied. Whenever the beginning and end concentrations are expected to be zero (or near zero) the steady state equations can also be used to predict the average concentration for a single task with multiple applications during the task, or even a series of such tasks. The transient equations should be used whenever these criteria cannot be met. A structured calibration procedure is proposed that utilizes a mass balance approach. Depending upon the DE model selected, one or more calibration measurements are collected. Using rearranged versions of the steady state equations, estimates of the model variables-e.g., the mass of the substance applied during each application, local exhaust capture efficiency, and the various cleaning or filtration efficiencies-can be calculated. A new procedure is proposed for estimating the emission rate constant.

  17. Three-dimensional visualization of morphology and ventilation procedure (air flow and diffusion) of a subdivision of the acinus using synchrotron radiation microtomography of the human lung specimens

    NASA Astrophysics Data System (ADS)

    Shimizu, Kenji; Ikura, Hirohiko; Ikezoe, Junpei; Nagareda, Tomofumi; Yagi, Naoto; Umetani, Keiji; Imai, Yutaka

    2004-04-01

    We have previously reported a synchrotron radiation (SR) microtomography system constructed at the bending magnet beamline at the SPring-8. This system has been applied to the lungs obtained at autopsy and inflated and fixed by Heitzman"s method. Normal lung and lung specimens with two different types of pathologic processes (fibrosis and emphysema) were included. Serial SR microtomographic images were stacked to yield the isotropic volumetric data with high-resolution (12 μm3 in voxel size). Within the air spaces of a subdivision of the acinus, each voxel is segmented three-dimensionally using a region growing algorithm ("rolling ball algorithm"). For each voxel within the segmented air spaces, two types of voxel coding have been performed: single-seeded (SS) coding and boundary-seeded (BS) coding, in which the minimum distance from an initial point as the only seed point and all object boundary voxels as a seed set were calculated and assigned as the code values to each voxel, respectively. With these two codes, combinations of surface rendering and volume rendering techniques were applied to visualize three-dimensional morphology of a subdivision of the acinus. Furthermore, sequentially filling process of air into a subdivision of the acinus was simulated under several conditions to visualize the ventilation procedure (air flow and diffusion). A subdivision of the acinus was reconstructed three-dimensionally, demonstrating the normal architecture of the human lung. Significant differences in appearance of ventilation procedure were observed between normal and two pathologic processes due to the alteration of the lung architecture. Three-dimensional reconstruction of the microstructure of a subdivision of the acinus and visualization of the ventilation procedure (air flow and diffusion) with SR microtomography would offer a new approach to study the morphology, physiology, and pathophysiology of the human respiratory system.

  18. Health-hazard evaluation report HETA 83-391-1683, Continental Coffee Products Company, Houston, Texas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnold, S.J.; Markel, H.L.; Morawetz, J.S.

    1986-04-01

    The International Chemical Workers Union requested an evaluation be made of the health status of employees at the Continental Coffee Products Company, Houston, Texas with particular attention given to potential exposure to pesticide residues on imported coffee beans. Analysis of air samples revealed the following concentration ranges: 29 personal respirable-dust samples ranging from 0.03 to 2.03 milligrams/cubic meter (mg/m3); 27 of 28 personal total dust samples, 0.09 to 2.65 mg/m3; four area respirable-dust samples, 0.11 to 0.53 mg/m3; and four area total dust samples, 0.16 to 2.39 mg/m3. Pesticide exposures were significantly below acceptable daily intakes. The authors conclude thatmore » it would not be expected that employees would be exposed to pesticide levels posing an appreciable threat to health. Recommendations were made to increase the use of local exhaust ventilation; to improve work practices to reduce generation of dust and accumulation; increase ventilation in the basement re-mix operation; and train employees toward the understanding of potential hazards and their role in controlling dust.« less

  19. Anaerobic threshold determination through ventilatory and electromyographics parameters.

    PubMed

    Gassi, E R; Bankoff, A D P

    2010-01-01

    The aim of present study was to compare the alterations in electromyography signs with Ventilatory Threshold (VT). Had been part of the study eight men, amateur cyclists and triathletes (25.25 +/- 6.96 years), that they had exercised themselves in a mechanical cicloergometer, a cadence of 80 RPM and with the increased intensity being in 25 W/min until the exhaustion. The VT was determined by a non-linear increase in VE/VO2 without any increase in VE/VCO2 and compared with the intensity corresponding to break point of amplitude EMG sign during the incremental exercise. The EMG--Fatigue Threshold (FT) and Ventilatory Threshold (VT) parameters used were the power, the time, absolute and relative VO2, ventilation (VE), the heart hate (HH) and the subjective perception of the effort. The results had not shown to difference in none of the variable selected for the corresponding intensity to VT and FT--EMG of the muscles lateralis vastus and femoris rectus. The parameters used in the comparison between the electromyographic indicators and ventilatory were the load, the time, absolute VO2 and relative to corporal mass, to ventilation (VE), the heart frequency (HH) and the Subjective Perception of the Effort (SPE).

  20. Acoustic Measurements of an Uninstalled Spacecraft Cabin Ventilation Fan Prototype

    NASA Technical Reports Server (NTRS)

    Koch, L. Danielle; Brown, Clifford A.; Shook, Tony D.; Winkel, James; Kolacz, John S.; Podboy, Devin M.; Loew, Raymond A.; Mirecki, Julius H.

    2012-01-01

    Sound pressure measurements were recorded for a prototype of a spacecraft cabin ventilation fan in a test in the NASA Glenn Acoustical Testing Laboratory. The axial fan is approximately 0.089 m (3.50 in.) in diameter and 0.223 m (9.00 in.) long and has nine rotor blades and eleven stator vanes. At design point of 12,000 rpm, the fan was predicted to produce a flow rate of 0.709 cu m/s (150 cfm) and a total pressure rise of 925 Pa (3.72 in. of water) at 12,000 rpm. While the fan was designed to be part of a ducted atmospheric revitalization system, no attempt was made to throttle the flow or simulate the installed configuration during this test. The fan was operated at six speeds from 6,000 to 13,500 rpm. A 13-microphone traversing array was used to collect sound pressure measurements along two horizontal planes parallel to the flow direction, two vertical planes upstream of the fan inlet and two vertical planes downstream of the fan exhaust. Measurements indicate that sound at blade passing frequency harmonics contribute significantly to the overall audible noise produced by the fan at free delivery conditions.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, Brett C.; Pass, Rebecca Zarin; Delp, William W.

    Combustion pollutant concentrations were measured during the scripted operation of natural gas cooking burners in nine homes. Boiling and simmering activities were conducted on the stovetop and in the oven with and without range hood exhaust ventilation or air mixing via a forced air system. Time-resolved concentrations of carbon dioxide (CO 2), nitric oxide (NO), nitrogen oxides (NO x), nitrogen dioxide (NO 2), particles with diameters of 6 nm or larger (PN), carbon monoxide (CO), and fine particulate matter (PM 2.5) were measured in the kitchen and bedroom area of each home. Four of the nine homes had kitchen 1more » h NO 2 exceed the national ambient air quality standard (100 ppb). In all homes, the highest 1 h integrated PN exceeded 2 × 10 5 cm -3-h, and the highest 4 h PN exceeded 3 × 10 5 cm -3-hr in the kitchen. Range hood performance varied widely, but one with a large capture volume and a measured flow of 108 L/s reduced concentrations 80–95%. Increased awareness of the need to ventilate when cooking, along with building standards for minimum range hood flow rates and volume, could substantially reduce exposures to NO 2 and ultrafine particles in homes.« less

  2. Exposure to Airborne Particles and Volatile Organic Compounds from Polyurethane Molding, Spray Painting, Lacquering, and Gluing in a Workshop

    PubMed Central

    Mølgaard, Bjarke; Viitanen, Anna-Kaisa; Kangas, Anneli; Huhtiniemi, Marika; Larsen, Søren Thor; Vanhala, Esa; Hussein, Tareq; Boor, Brandon E.; Hämeri, Kaarle; Koivisto, Antti Joonas

    2015-01-01

    Due to the health risk related to occupational air pollution exposure, we assessed concentrations and identified sources of particles and volatile organic compounds (VOCs) in a handcraft workshop producing fishing lures. The work processes in the site included polyurethane molding, spray painting, lacquering, and gluing. We measured total VOC (TVOC) concentrations and particle size distributions at three locations representing the various phases of the manufacturing and assembly process. The mean working-hour TVOC concentrations in three locations studied were 41, 37, and 24 ppm according to photo-ionization detector measurements. The mean working-hour particle number concentration varied between locations from 3000 to 36,000 cm−3. Analysis of temporal and spatial variations of TVOC concentrations revealed that there were at least four substantial VOC sources: spray gluing, mold-release agent spraying, continuous evaporation from various lacquer and paint containers, and either spray painting or lacquering (probably both). The mold-release agent spray was indirectly also a major source of ultrafine particles. The workers’ exposure can be reduced by improving the local exhaust ventilation at the known sources and by increasing the ventilation rate in the area with the continuous source. PMID:25849539

  3. Analysis of activated air following high yield shots in the NIF

    DOE PAGES

    Khater, Hesham; Brereton, Sandra

    2015-07-24

    During the ignition experimental campaign, the National Ignition Facility (NIF) is expected to perform shots with varying fusion yield (up to 20 MJ or 7.1 x 10 18 neutrons per shot) and a maximum annual yield of 1200 MJ. A detailed MCNP model of the Target Bay (TB) and the two switchyards (SY) has been developed to estimate the post-shot radiation environment inside the facility. During D-T shots, a pulse of 14.1 MeV neutrons streaming outside the Target Chamber (TC) will activate the air present inside the TB and the argon gas inside the laser tubes. Smaller levels of activitymore » are also generated in the SY air and in the argon portion of the SY laser beam path. The activated TB air will be mixed with fresh air from the Operations Support Building (OSB) before release through the stack. Flow of activated air from the Target Bay is controlled by the heating, ventilating, and air conditioning (HVAC) system. 16N (T 1/2 = 7.13 s) dominates the radiation levels during the first minute following the shot. It is expected that 16N will decay away during the confinement time before releasing the TB air through the stack. The other major contributors are 13N (T 1/2 = 9.97 min) and 41Ar (T 1/2 = 1.83 h). In general a low dose rate of < 1 μSv/h is expected near the stack during the first few hours following a 20 MJ shot. Here, the amount of activated Target Bay air released through the stack is very small and does not pose significant hazard to personnel or the environment. In the mean time, due to a very small leakage rate out of the laser tubes, the activated argon gas decays within the tubes and any resulting release to the environment is insignificant.« less

  4. Analysis of activated air following high yield shots in the NIF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khater, Hesham; Brereton, Sandra

    During the ignition experimental campaign, the National Ignition Facility (NIF) is expected to perform shots with varying fusion yield (up to 20 MJ or 7.1 x 10 18 neutrons per shot) and a maximum annual yield of 1200 MJ. A detailed MCNP model of the Target Bay (TB) and the two switchyards (SY) has been developed to estimate the post-shot radiation environment inside the facility. During D-T shots, a pulse of 14.1 MeV neutrons streaming outside the Target Chamber (TC) will activate the air present inside the TB and the argon gas inside the laser tubes. Smaller levels of activitymore » are also generated in the SY air and in the argon portion of the SY laser beam path. The activated TB air will be mixed with fresh air from the Operations Support Building (OSB) before release through the stack. Flow of activated air from the Target Bay is controlled by the heating, ventilating, and air conditioning (HVAC) system. 16N (T 1/2 = 7.13 s) dominates the radiation levels during the first minute following the shot. It is expected that 16N will decay away during the confinement time before releasing the TB air through the stack. The other major contributors are 13N (T 1/2 = 9.97 min) and 41Ar (T 1/2 = 1.83 h). In general a low dose rate of < 1 μSv/h is expected near the stack during the first few hours following a 20 MJ shot. Here, the amount of activated Target Bay air released through the stack is very small and does not pose significant hazard to personnel or the environment. In the mean time, due to a very small leakage rate out of the laser tubes, the activated argon gas decays within the tubes and any resulting release to the environment is insignificant.« less

  5. Laboratory evaluation to reduce respirable crystalline silica dust when cutting concrete roofing tiles using a masonry saw.

    PubMed

    Carlo, Rebecca V; Sheehy, John; Feng, H Amy; Sieber, William K

    2010-04-01

    Respirable crystalline silica dust exposure in residential roofers is a recognized hazard resulting from cutting concrete roofing tiles. Roofers cutting tiles using masonry saws can be exposed to high concentrations of respirable dust. Silica exposures remain a serious threat for nearly two million U.S. construction workers. Although it is well established that respiratory diseases associated with exposure to silica dust are preventable, they continue to occur and cause disability or death. The effectiveness of both a commercially available local exhaust ventilation (LEV) system and a water suppression system in reducing silica dust was evaluated separately. The LEV system exhausted 0.24, 0.13, or 0.12 m(3)/sec of dust laden air, while the water suppression system supplied 0.13, 0.06, 0.03, or 0.02 L/sec of water to the saw blade. Using a randomized block design, implemented under laboratory conditions, the aforementioned conditions were evaluated independently on two types of concrete roofing tiles (s-shape and flat) using the same saw and blade. Each engineering control (LEV or water suppression) was replicated eight times, or four times for each type of tile. Analysis of variance was performed by comparing the mean airborne respirable dust concentrations generated during each run and engineering control treatment. The use of water controls and ventilation controls compared with the "no control" treatment resulted in a statistically significant (p < 0.05) reduction of mean respirable dust concentrations generated per tile cut. The percent reduction for respirable dust concentrations was 99% for the water control and 91% for the LEV. Results suggest that water is an effective method for reducing crystalline silica exposures. However, water damage potential, surface discolorations, cleanup, slip hazards, and other requirements may make the use of water problematic in many situations. Concerns with implementing an LEV system to control silica dust exposures include sufficient capture velocity, additional weight of the saw with the LEV system, electricity connections, and cost of air handling unit.

  6. Evaluation of preventive and control measures for lead exposure in a South African lead-acid battery recycling smelter.

    PubMed

    Dyosi, Sindiswa

    2007-10-01

    In South Africa, new lead regulations released in February 2002 served as motivation for a cross-sectional study investigating the effectiveness of preventive and control measures implemented in a lead smelter that recycles lead-acid batteries. Twenty-two workers were observed and interviewed. Structured questionnaires were used to gather workers' personal information, perception about their work environment, health risks, and work practices. Retrospective data from air monitoring and medical surveillance programs were obtained from the plant's records. The smelter implemented a number of control measures for lead exposure, including engineering controls, administrative controls, and, as a last resort, personal protective equipment. Engineering controls were rated the best control measure and included local exhaust ventilation systems and wet methods. Positive pressure systems were used in the offices and laboratory. The local exhaust ventilation system was rated the best engineering control measure. Although control measures were used, areas such as smelting and refinery had average lead in air levels above 0.15 mg/m(3), the occupational exposure limit for lead. This was a concern especially with regard to the smelting area because those workers had the second highest mean blood lead levels; workers in the battery breaking area had the highest. Regular use of personal protective equipment by some workers in the "lead exposure zones" was not observed. Although the mean blood lead levels had been below 40 micro g/dL for more than 90% of the workers since 2001, more than 70% of workers reported concerns about their health while working in the smelter. Even though control measures were implemented, they were not adequate because in some areas lead in air exceeded the occupational exposure limit. Therefore, improvement of existing measures and regular monitoring of personal protective equipment use were included in the recommendations given to the smelter.

  7. Effects of elevated oxygen and carbon dioxide partial pressures on respiratory function and cognitive performance.

    PubMed

    Gill, Matthew; Natoli, Michael J; Vacchiano, Charles; MacLeod, David B; Ikeda, Keita; Qin, Michael; Pollock, Neal W; Moon, Richard E; Pieper, Carl; Vann, Richard D

    2014-08-15

    Hyperoxia during diving has been suggested to exacerbate hypercapnic narcosis and promote unconsciousness. We tested this hypothesis in male volunteers (12 at rest, 10 at 75 W cycle ergometer exercise) breathing each of four gases in a hyperbaric chamber. Inspired Po2 (PiO2 ) was 0.21 and 1.3 atmospheres (atm) without or with an individual subject's maximum tolerable inspired CO2 (PiO2 = 0.055-0.085 atm). Measurements included end-tidal CO2 partial pressure (PetCO2 ), rating of perceived discomfort (RPD), expired minute ventilation (V̇e), and cognitive function assessed by auditory n-back test. The most prominent finding was, irrespective of PetCO2 , that minute ventilation was 8-9 l/min greater for rest or exercise with a PiO2 of 1.3 atm compared with 0.21 atm (P < 0.0001). For hyperoxic gases, PetCO2 was consistently less than for normoxic gases (P < 0.01). For hyperoxic hypercapnic gases, n-back scores were higher than for normoxic gases (P < 0.01), and RPD was lower for exercise but not rest (P < 0.02). Subjects completed 66 hyperoxic hypercapnic trials without incident, but five stopped prematurely because of serious symptoms (tunnel vision, vision loss, dizziness, panic, exhaustion, or near syncope) during 69 normoxic hypercapnic trials (P = 0.0582). Serious symptoms during hypercapnic trials occurred only during normoxia. We conclude serious symptoms with hyperoxic hypercapnia were absent because of decreased PetCO2 consequent to increased ventilation. Copyright © 2014 the American Physiological Society.

  8. Energy absorption characteristics of lightweight structural member by stacking conditions

    NASA Astrophysics Data System (ADS)

    Choi, Juho; Yang, Yongjun; Hwang, Woochae; Pyeon, Seokbeom; Min, Hanki; Yeo, Ingoo; Yang, Inyoung

    2011-11-01

    The recent trend in vehicle design is aimed at improving crash safety and environmental-friendliness. To solve these issues, the needs for lighter vehicle to limit exhaust gas and improve fuel economy has been requested for environmental-friendliness. Automobile design should be made for reduced weight once the safety of vehicle is maintained. In this study, composite structural members were manufactured using carbon fiber reinforced plastic (CFRP) which are representative lightweight structural materials. Carbon fiber has been researched as alternative to metals for lightweight vehicle and better fuel economy. CFRP is an anisotropic material which is the most widely adapted lightweight structural member because of their inherent design flexibility and high specific strength and stiffness. Also, variation of CFRP interface number is important to increase the energy absorption capacity. In this study, one type of circular shaped composite tube was used, combined with reinforcing foam. The stacking condition was selected to investigate the effect of the fiber orientation angle and interface number. The crashworthy behavior of circular composite material tubes subjected to static axial compression under same conditions is reported. The axial static collapse tests were carried out for each section member. The collapse modes and the energy absorption capability of the members were analyzed.

  9. Energy absorption characteristics of lightweight structural member by stacking conditions

    NASA Astrophysics Data System (ADS)

    Choi, Juho; Yang, Yongjun; Hwang, Woochae; Pyeon, Seokbeom; Min, Hanki; Yeo, Ingoo; Yang, Inyoung

    2012-04-01

    The recent trend in vehicle design is aimed at improving crash safety and environmental-friendliness. To solve these issues, the needs for lighter vehicle to limit exhaust gas and improve fuel economy has been requested for environmental-friendliness. Automobile design should be made for reduced weight once the safety of vehicle is maintained. In this study, composite structural members were manufactured using carbon fiber reinforced plastic (CFRP) which are representative lightweight structural materials. Carbon fiber has been researched as alternative to metals for lightweight vehicle and better fuel economy. CFRP is an anisotropic material which is the most widely adapted lightweight structural member because of their inherent design flexibility and high specific strength and stiffness. Also, variation of CFRP interface number is important to increase the energy absorption capacity. In this study, one type of circular shaped composite tube was used, combined with reinforcing foam. The stacking condition was selected to investigate the effect of the fiber orientation angle and interface number. The crashworthy behavior of circular composite material tubes subjected to static axial compression under same conditions is reported. The axial static collapse tests were carried out for each section member. The collapse modes and the energy absorption capability of the members were analyzed.

  10. Comprehensive simultaneous shipboard and airborne characterization of exhaust from a modern container ship at sea.

    PubMed

    Murphy, Shane M; Agrawal, Harshit; Sorooshian, Armin; Padró, Luz T; Gates, Harmony; Hersey, Scott; Welch, W A; Lung, H; Miller, J W; Cocker, David R; Nenes, Athanasios; Jonsson, Haflidi H; Flagan, Richard C; Seinfeld, John H

    2009-07-01

    We report the first joint shipboard and airborne study focused on the chemical composition and water-uptake behavior of particulate ship emissions. The study focuses on emissions from the main propulsion engine of a Post-Panamax class container ship cruising off the central coast of California and burning heavy fuel oil. Shipboard sampling included micro-orifice uniform deposit impactors (MOUDI) with subsequent off-line analysis, whereas airborne measurements involved a number of real-time analyzers to characterize the plume aerosol, aged from a few seconds to over an hour. The mass ratio of particulate organic carbon to sulfate at the base of the ship stack was 0.23 +/- 0.03, and increased to 0.30 +/- 0.01 in the airborne exhaust plume, with the additional organic mass in the airborne plume being concentrated largely in particles below 100 nm in diameter. The organic to sulfate mass ratio in the exhaust aerosol remained constant during the first hour of plume dilution into the marine boundary layer. The mass spectrum of the organic fraction of the exhaust aerosol strongly resembles that of emissions from other diesel sources and appears to be predominantly hydrocarbon-like organic (HOA) material. Background aerosol which, based on air mass back trajectories, probably consisted of aged ship emissions and marine aerosol, contained a lower organic mass fraction than the fresh plume and had a much more oxidized organic component. A volume-weighted mixing rule is able to accurately predict hygroscopic growth factors in the background aerosol but measured and calculated growth factors do not agree for aerosols in the ship exhaust plume. Calculated CCN concentrations, at supersaturations ranging from 0.1 to 0.33%, agree well with measurements in the ship-exhaust plume. Using size-resolved chemical composition instead of bulk submicrometer composition has little effect on the predicted CCN concentrations because the cutoff diameter for CCN activation is larger than the diameter where the mass fraction of organic aerosol begins to increase significantly. The particle number emission factor estimated from this study is 1.3 x 10(16) (kg fuel)(-1), with less than 1/10 of the particles having diameters above 100 nm; 24% of particles (>10 nm in diameter) activate into cloud droplets at 0.3% supersaturation.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacDonald, R.; Kelley, D.E.

    In 1998, when Sunlaw Energy Corporation needed to retrofit their two natural gas fired power plants to meet new emissions requirements that were soon to come into place, they looked at existing technologies and found them either economically or environmentally undesirable. With the help of General Electric they developed a program of water injection that was capable of reducing the NO{sub x} emissions to 25 ppm. This, however, was not low enough to meet coming regulations. Sunlaw concluded that the best option for pollution control was to invert their own system. A partnership was formed between Sunlaw and Advanced Catalystmore » Systems, a catalyst development and manufacturing firm. The result of their efforts was Goal Line Environmental Technologies and the SCONOx catalytic absorption system. The newest SCONOx system, commissioned at Sunlaw's Federal cogeneration plant in December 1996, treats the exhaust of a GELM2500 gas turbine. Combined with water injection, it has reduced NO{sub x} emission from 160 ppm down to 1--2 ppm. Carbon monoxide emissions are virtually eliminated, with stack readings less than ambient levels. The SCONOx system uses single catalyst for both CO and NO{sub x} control. It oxidizes CO to CO{sub 2} and NO to NO{sub 2}, and the NO{sub 2} is then absorbed onto the surface of the catalyst. Just as a sponge absorbs water and must be periodically regenerated, the catalyst must be regenerated. This is accomplished by passing a dilute hydrogen gas across the surface of the catalyst in the absence of oxygen. Nitrogen oxygen are broken down into nitrogen and water, and this is exhausted up the stack instead of NO{sub x}. The SCONOx system is a breakthrough in CO and NO{sub x} control technology that makes it possible to have clean air without the use of ammonia or other hazardous materials. It is truly an environmentally friendly NO{sub x} system.« less

  12. Health hazard evaluation determination report No. 78-128-549, Nixon Power Plant, Colorado Springs, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gunter, B.J.

    1978-12-01

    Asbestos (CAS 1332-21-4) concentrations during sanding and buffing operations were measured at the Nixon Power facility (SIC-4911) in Colorado Springs, Colorado on September 29, 1978. The evaluation was requested by the vice president of the Watkin Construction Company on behalf of plumbers engaged in sanding asbestos joints and connections. Breathing zone asbestos concentrations of fibers greater than five microns in length ranged from 0.02 to 0.187 fibers per cubic centimeter. The OSHA asbestos standard of 2 fibers per cubic centimeter was not exceeded, however, the author concludes that a potential asbestos hazard does exist. He recommends that respirators be usedmore » by workers until exhaust ventilation is provided.« less

  13. Development of Smart Ventilation Control Algorithms for Humidity Control in High-Performance Homes in Humid U.S. Climates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Less, Brennan; Walker, Iain; Ticci, Sara

    Past field research and simulation studies have shown that high performance homes experience elevated indoor humidity levels for substantial portions of the year in humid climates. This is largely the result of lower sensible cooling loads, which reduces the moisture removed by the cooling system. These elevated humidity levels lead to concerns about occupant comfort, health and building durability. Use of mechanical ventilation at rates specified in ASHRAE Standard 62.2-2013 are often cited as an additional contributor to humidity problems in these homes. Past research has explored solutions, including supplemental dehumidification, cooling system operational enhancements and ventilation system design (e.g.,more » ERV, supply, exhaust, etc.). This project’s goal is to develop and demonstrate (through simulations) smart ventilation strategies that can contribute to humidity control in high performance homes. These strategies must maintain IAQ via equivalence with ASHRAE Standard 62.2-2013. To be acceptable they must not result in excessive energy use. Smart controls will be compared with dehumidifier energy and moisture performance. This work explores the development and performance of smart algorithms for control of mechanical ventilation systems, with the objective of reducing high humidity in modern high performance residences. Simulations of DOE Zero-Energy Ready homes were performed using the REGCAP simulation tool. Control strategies were developed and tested using the Residential Integrated Ventilation (RIVEC) controller, which tracks pollutant exposure in real-time and controls ventilation to provide an equivalent exposure on an annual basis to homes meeting ASHRAE 62.2-2013. RIVEC is used to increase or decrease the real-time ventilation rate to reduce moisture transport into the home or increase moisture removal. This approach was implemented for no-, one- and two-sensor strategies, paired with a variety of control approaches in six humid climates (Miami, Orlando, Houston, Charleston, Memphis and Baltimore). The control options were compared to a baseline system that supplies outdoor air to a central forced air cooling (and heating) system (CFIS) that is often used in hot humid climates. Simulations were performed with CFIS ventilation systems operating on a 33% duty-cycle, consistent with 62.2-2013. The CFIS outside airflow rates were set to 0%, 50% and 100% of 62.2-2013 requirements to explore effects of ventilation rate on indoor high humidity. These simulations were performed with and without a dehumidifier in the model. Ten control algorithms were developed and tested. Analysis of outdoor humidity patterns facilitated smart control development. It was found that outdoor humidity varies most strongly seasonally—by month of the year—and that all locations follow the similar pattern of much higher humidity during summer. Daily and hourly variations in outdoor humidity were found to be progressively smaller than the monthly seasonal variation. Patterns in hourly humidity are driven by diurnal daily patterns, so they were predictable but small, and were unlikely to provide much control benefit. Variation in outdoor humidity between days was larger, but unpredictable, except by much more complex climate models. We determined that no-sensor strategies might be able to take advantage of seasonal patterns in humidity, but that real-time smart controls were required to capture variation between days. Sensor-based approaches are also required to respond dynamically to indoor conditions and variations not considered in our analysis. All smart controls face trade-offs between sensor accuracy, cost, complexity and robustness.« less

  14. No positive influence of ingesting chia seed oil on human running performance.

    PubMed

    Nieman, David C; Gillitt, Nicholas D; Meaney, Mary Pat; Dew, Dustin A

    2015-05-15

    Runners (n = 24) reported to the laboratory in an overnight fasted state at 8:00 am on two occasions separated by at least two weeks. After providing a blood sample at 8:00 am, subjects ingested 0.5 liters flavored water alone or 0.5 liters water with 7 kcal kg-1 chia seed oil (random order), provided another blood sample at 8:30 am, and then started running to exhaustion (~70% VO2max). Additional blood samples were collected immediately post- and 1-h post-exercise. Despite elevations in plasma alpha-linolenic acid (ALA) during the chia seed oil (337%) versus water trial (35%) (70.8 ± 8.6, 20.3 ± 1.8 μg mL(-1), respectively, p < 0.001), run time to exhaustion did not differ between trials (1.86 ± 0.10, 1.91 ± 0.13 h, p = 0.577, respectively). No trial differences were found for respiratory exchange ratio (RER) (0.92 ± 0.01), oxygen consumption, ventilation, ratings of perceived exertion (RPE), and plasma glucose and blood lactate. Significant post-run increases were measured for total leukocyte counts, plasma cortisol, and plasma cytokines (Interleukin-6 (IL-6), Interleukin-8 (IL-8), Interleukin-10 (IL-10), and Tumor necrosis factors-α (TNF-α)), with no trial differences. Chia seed oil supplementation compared to water alone in overnight fasted runners before and during prolonged, intensive running caused an elevation in plasma ALA, but did not enhance run time to exhaustion, alter RER, or counter elevations in cortisol and inflammatory outcome measures.

  15. STEAM PLANT, TRA609. SECTION A SHOWS FEATURES OF NORTH/SOUTH AXIS: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    STEAM PLANT, TRA-609. SECTION A SHOWS FEATURES OF NORTH/SOUTH AXIS: STEAM GENERATOR AND CATWALK, STACK, DEGREASER FEED WATER HEATER IN PENTHOUSE, MEZZANINE, SURGE TANK PIT (BELOW GROUND LEVEL). UTILITY ROOM SHOWS DIESEL ENGINE GENERATORS, AIR TANKS, STARTING AIR COMPRESSORS. OUTSIDE SOUTH END ARE EXHAUST MUFFLER, AIR INTAKE OIL FILTER, RADIATOR COOLING UNIT, AIR SURGE TANK. SECTION B CROSSES WEST TO EAST NEAR SOUTH END OF BUILDING TO SHOW ARRANGEMENT OF DIESEL ENGINE GENERATOR, AIR DRIER, AFTER COOLER, AIR COMPRESSOR, AND BLOWDOWN TANK. BLAW-KNOX 3150-9-2, 6/1950. INL INDEX NO. 431-0609-00-098-100018, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  16. Groundwater impact assessment report for the 216-S-26 Crib, 200 West Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindberg, J.W.; Evelo, S.D.; Alexander, D.J.

    1993-11-01

    This report assesses the impact of wastewater discharged to the 216-S-26 Crib on groundwater quality. The 216-S-26 Crib, located in the southern 200 West Area, has been in use since 1984 to dispose of liquid effluents from the 222-S Laboratory Complex. The 222-S Laboratory Complex effluent stream includes wastewater from four sources: the 222-S Laboratory, the 219-S Waste Storage Facility, the 222-SA Chemical Standards Laboratory, and the 291-S Exhaust Fan Control House and Stack. Based on assessment of groundwater chemistry and flow data, contaminant transport predictions, and groundwater chemistry data, the 216-S-26 Crib has minimal influence on groundwater contamination inmore » the southern 200 West Area.« less

  17. A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions

    NASA Astrophysics Data System (ADS)

    Ai, Z. T.; Mak, C. M.

    2014-05-01

    This study examines the interunit dispersion characteristics in and around multistory buildings under wind-induced single-sided ventilation conditions using computational fluid dynamics (CFD) method, under the hypothesis that infectious respiratory aerosols exhausted from a unit can reenter into another unit in a same building through opened windows. The effect of balconies on the interunit dispersion pattern is considered. The RNG k - ɛ model and the two-layer near-wall model are employed to establish the coupled indoor and outdoor airflow field, and the tracer gas technique is adopted to simulate pollutant dispersion. Reentry ratios from each unit to other units under prevailing wind directions are quantified and the possible interunit dispersion routes are then revealed. It is found that many reentry ratios appear to reach around 10.0%, suggesting that the interunit dispersion is an important pollutant transmission route. The interunit dispersion pattern is highly dependent on the incident wind direction and the fact whether the building has protrusive envelope features. On average, the strongest dispersion occurs on the windward wall of the buildings under oblique wind direction, owing to high ACH (air change per hour) values and unidirectional spread routes. Except under a normal incident wind, the presence of balconies intensifies the interunit dispersion by forming dispersion channels to increase the reentry ratios.

  18. Operative rigid bronchoscopy: indications, basic techniques and results.

    PubMed

    Petrella, Francesco; Borri, Alessandro; Casiraghi, Monica; Cavaliere, Sergio; Donghi, Stefano; Galetta, Domenico; Gasparri, Roberto; Guarize, Juliana; Pardolesi, Alessandro; Solli, Piergiorgio; Tessitore, Adele; Venturino, Marco; Veronesi, Giulia; Spaggiari, Lorenzo

    2014-05-27

    Palliative airway treatments are essential to improve quality and length of life in lung cancer patients with central airway obstruction. Rigid bronchoscopy has proved to be an excellent tool to provide airway access and control in this cohort of patients. The main indication for rigid bronchoscopy in adult bronchology remains central airway obstruction due to neoplastic or non-neoplastic disease. We routinely use negative pressure ventilation (NPV) under general anaesthesia to prevent intraoperative apnoea and respiratory acidosis. This procedure allows opioid sparing, a shorter recovery time and avoids manually assisted ventilation, thereby reducing the amount of oxygen needed, while maintaining optimal surgical conditions. The major indication for NPV rigid bronchoscopy at our institution has been airway obstruction by neoplastic tracheobronchial tissue, mainly treated by laser-assisted mechanical dissection. When strictly necessary, we use silicone stents for neoplastic or cicatricial strictures, reserving metal stents to cover tracheo-oesophageal fistulae. NPV rigid bronchoscopy is an excellent tool for the endoscopic treatment of locally advanced tumours of the lung, especially when patients have exhausted the conventional therapeutic resources. Laser-assisted mechanical resection and stent placement are the most effective procedures for preserving quality of life in patients with advanced stage cancer. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-thoracic Surgery. All rights reserved.

  19. Assessment of workplace air concentrations of formaldehyde during and before working hours in medical facilities.

    PubMed

    Higashikubo, Ichiro; Miyauchi, Hiroyuki; Yoshida, Satoru; Tanaka, Shinsuke; Matsuoka, Mitsunori; Arito, Heihachiro; Araki, Akihiro; Shimizu, Hidesuke; Sakurai, Haruhiko

    2017-04-07

    Workplace air concentrations of formaldehyde (FA) in medical facilities where FA and FA-treated organs were stored and handled were measured before and during working hours and assessed by the official method specified by Work Environment Measurement Law. Sixty-percent of the total facilities examined were judged as inappropriately controlled work environment. The concentrations of FA before working hours by spot sampling were found to exceed 0.1 ppm in some facilities, and tended to increase with increasing volume of containers storing FA and FA-treated materials. Regression analysis revealed that logarithmic concentrations of FA during working hours by the Law-specified analytical method were highly correlated with those before working hours by spot sampling, suggesting the importance for appropriate storing methods of FA and FA-treated materials. The concentrations of FA during working hours are considered to be lowered by effective ventilation of FA-contaminated workplace air and appropriate storage of FA and FA-treated materials in plastic containers in the medical facilities. In particular, such improvement by a local exhaust ventilation system and tightly-sealed containment of FA-treated material were urgently needed for the dissecting room where FA-treated cadavers were prepared and handled for a gross anatomy course in a medical school.

  20. Reduction of air pollutant concentrations in an indoor ice-skating rink

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, K.; Yanagisawa, Yukio; Spengler, J.D.

    1994-01-01

    High carbon monoxide and nitrogen dioxide concentrations were measured in an indoor ice-skating rink with fuel-powered ice-resurfacing equipment. In 22% to 33% of the measurements over 90-min segments, CO concentrations exceeded 20 [mu]L/L as a 90-min average in the absence of rink ventilation. Average NO[sub 2] concentrations over 14 h were higher than 600 nL/L. Reduction of air pollutant concentrations in the ice-skating rink is necessary to prevent air-pollutant-exposure-related health incidents. Various methods for reducing air pollutants in an ice-skating rink were evaluated by simultaneously measuring CO and NO[sub 2] concentrations. Single pollution reduction attempts, such as extension of themore » exhaust pipe, reduction in the number of resurfacer operations, or use of an air recirculation system, did not significantly reduce air pollutant concentrations in the rink. Full operation of the mechanical ventilation system combined with reduced resurfacer operation was required to keep the air pollutant levels in the skating rink below the recommended guidelines. This investigation showed that management of clean air quality in an ice-skating rink is practically difficult as long as fuel-powered resurfacing equipment is used. 16 refs., 3 figs., 5 tabs.« less

  1. Energy saving technologies of the decentralized ventilation of buildings

    NASA Astrophysics Data System (ADS)

    Mansurov, R. Sh; Rafalskaya, T. A.

    2017-11-01

    The growing aspiration to energy saving and efficiency of energy leads to necessity to build tight enough buildings. As a result of this the quantity of infiltration air appears insufficient for realization of necessary air exchange in. One of decisions of the given problem is development and application for ventilation of premises of the decentralized forced-air and exhaust systems (DFAES) with recuperative or regenerative heat-exchangers. For an estimation of efficiency of DFAES following basic parameters have been certain: factor of energy saving; factor of efficiency of energy; factor of a heat transfer; factor of an effective utilization of a surface of heat exchange. Were estimated temperature of forced air; actual speed of an air jet on an entrance in a served zone; actual noise level; the charge of external air. Tests of DFAES were spent in natural conditions at which DFAES influenced all set of factors both an external climate, and an internal microclimate of a premise, and also the arrangement on a wind side or behind wind side of a building, influence of surrounding building, fluctuation of temperature of external air is considered. Proceeding from results and the analysis of the lead researches recommendations have been developed for development and manufacture of new sample of DFAES.

  2. Respiratory muscle endurance, oxygen saturation index in vastus lateralis and performance during heavy exercise.

    PubMed

    Oueslati, Ferid; Boone, Jan; Ahmaidi, Said

    2016-06-15

    The purpose of this study was to investigate the relationships between respiratory muscle endurance, tissue oxygen saturation index dynamics of leg muscle (TSI) and the time to exhaustion (TTE) during high intensity exercise. Eleven males performed a respiratory muscle endurance test, a maximal incremental running field test (8 km h(-1)+0.5 km h(-1) each 60s) and a high-intensity constant speed field test at 90% VO2max. The TSI in vastus lateralis was monitored with near-infrared spectroscopy. The TSI remained steady between 20 and 80% of TTE. Between 80 and 100% of TTE (7.5 ± 6.1%, p<0.05), a significant drop in TSI concomitant with a minute ventilation increase (16 ± 10 l min(-1)) was observed. Moreover, the increase of ventilation was correlated to the drop in TSI (r=0.70, p<0.05). Additionally, respiratory muscle endurance was significantly correlated to TSI time plateau (20-80% TTE) (r=0.83, p<0.05) and to TTE (r=0.95, p<0.001). The results of the present study show that the tissue oxygen saturation plateau might be affected by ventilatory work and that respiratory muscle endurance could be considered as a determinant of performance during heavy exercise. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Rationing of resources: ethical issues in disasters and epidemic situations.

    PubMed

    Lin, Janet Y; Anderson-Shaw, Lisa

    2009-01-01

    In an epidemic situation or large-scale disaster, medical and human resources may be stretched to the point of exhaustion. Appropriate planning must incorporate plans of action that minimize public health morbidity and mortality while maximizing the appropriate use of medical and human healthcare resources. While the current novel H1N1 influenza has spread throughout the world, the severity of this strain of influenza appears to be relatively less virulent and lethal compared to the 1918 influenza pandemic. However, the presence of this new influenza strain has reignited interest in pandemic planning. Amongst other necessary resources needed to combat pandemic influenza, a major medical resource concern is the limited number of mechanical ventilators that would be available to be used to treat ill patients. Recent reported cases of avian influenza suggest that mechanical ventilation will be required for the successful recovery of many individuals ill with this strain of virus. However, should the need for ventilators exceed the number of available machines, how will care providers make the difficult ethical decisions as to who should be placed or who should remain on these machines as more influenza patients arrive in need of care? This paper presents a decision-making model for clinicians that is based upon the bioethical principles of beneficence and justice. The model begins with the basic assumptions of triage and progresses into a useful algorithm based upon utilitarian principles. The model is intended to be used as a guide for clinicians in making decisions about the allocation of scarce resources in a just manner and to serve as an impetus for institutions to create or adapt plans to address resource allocation issues should the need arise.

  4. Airborne nanoparticle concentrations in the manufacturing of polytetrafluoroethylene (PTFE) apparel.

    PubMed

    Vosburgh, Donna J H; Boysen, Dane A; Oleson, Jacob J; Peters, Thomas M

    2011-03-01

    One form of waterproof, breathable apparel is manufactured from polytetrafluoroethylene (PTFE) membrane laminated fabric using a specific process to seal seams that have been sewn with traditional techniques. The sealing process involves applying waterproof tape to the seam by feeding the seam through two rollers while applying hot air (600 °C). This study addressed the potential for exposure to particulate matter from this sealing process by characterizing airborne particles in a facility that produces more than 1000 lightweight PTFE rain jackets per day. Aerosol concentrations throughout the facility were mapped, breathing zone concentrations were measured, and hoods used to ventilate the seam sealing operation were evaluated. The geometric mean (GM) particle number concentrations were substantially greater in the sewing and sealing areas (67,000 and 188,000 particles cm⁻³)) compared with that measured in the office area (12,100 particles cm⁻³). Respirable mass concentrations were negligible throughout the facility (GM = 0.002 mg m⁻³) in the sewing and sealing areas). The particles exiting the final discharge of the facility's ventilation system were dominated by nanoparticles (number median diameter = 25 nm; geometric standard deviation of 1.39). The breathing zone particle number concentrations of the workers who sealed the sewn seams were highly variable and significantly greater when sealing seams than when conducting other tasks (p < 0.0001). The sealing workers' breathing zone concentrations ranged from 147,000 particles cm⁻³ to 798,000 particles cm⁻³, and their seam responsibility significantly influenced their breathing zone concentrations (p = 0.03). The finding that particle number concentrations were approximately equal outside the hood and inside the local exhaust duct indicated poor effectiveness of the canopy hoods used to ventilate sealing operations.

  5. Airborne Nanoparticle Concentrations in the Manufacturing of Polytetrafluoroethylene (PTFE) Apparel

    PubMed Central

    Vosburgh, Donna J.H.; Boysen, Dane A.; Oleson, Jacob J.; Peters, Thomas M.

    2016-01-01

    One form of waterproof, breathable apparel is manufactured from polytetrafluoroethylene (PTFE) membrane laminated fabric, using a specific process to seal seams that have been sewn with traditional techniques. The sealing process involves applying waterproof tape to the seam by feeding the seam through two rollers while applying hot air (600°C). This study addressed the potential for exposure to particulate matter from this sealing process, by characterizing airborne particles in a facility that produces over 1,000 lightweight PTFE rain jackets per day. Aerosol concentrations throughout the facility were mapped, breathing zone concentrations were measured, and hoods used to ventilate the seam sealing operation were evaluated. The geometric mean (GM) particle number concentrations were substantially greater in the sewing and sealing areas (67,000 and 188,000 particles cm−3) compared to that measured in the office area (12,100 particles cm−3). Respirable mass concentrations were negligible throughout the facility (GM=0.002 mg m−3 in the sewing and sealing areas). The particles exiting the final discharge of the facility's ventilation system were dominated by nanoparticles (number median diameter = 25 nm; geometric standard deviation of 1.39). The breathing zone particle number concentrations of the workers who sealed the sewn seams were highly variable and significantly greater when sealing seams than when conducting other tasks (p<0.0001). The sealing workers’ breathing zone concentrations ranged from 147,000 particles cm−3 to 798,000 particles cm−3, and their seam responsibility significantly influenced their breathing zone concentrations (p=0.03). The finding that particle number concentrations were approximately equal outside the hood and inside the local exhaust duct indicated poor effectiveness of the canopy hoods used to ventilate sealing operations. PMID:21347955

  6. Development of a new dynamic chamber system for measuring harmful gas emissions from composting livestock waste.

    PubMed

    Osada, T; Fukumoto, Y

    2001-01-01

    A dynamic chamber system consisting of a chamber covering a composting mixture (3 m in diameter, 2.2 m in height, 13 m3), a ventilator for suction of air into the chamber, and equipment to measure the gas composition and indicate temperature, was developed for evaluation of harmful gas emissions from such livestock waste composting. Fresh air was introduced through the space between the floor and the lower edge of the chamber, and exhaust gas was removed through an outlet placed on top of the chamber. NH3, CH4 and N2O concentrations in exhaust air from the chamber were measured by Infrared Photoacoustic Detector (IPD, multi gas monitor type 1312, INNOVA, Copenhagen, Denmark) at 5 minutes intervals. The system was evaluated with standard gas of NH3, CH4 and N2O. High recoveries of 98.5% (NH3, SD 6.25), 96.6% (CH4, SD 4.03) and 99.5% ( N2O, SD 2.68) were obtained for each gas emission in the chamber over 17-20 min. The measured values of those gases obtained by the IPD method and conventional method at the time of a composting examination of swine waste were measured, and the differences were only a few percent of the total emissions.

  7. Biological exhaust air treatment systems as a potential microbial risk for farm animals assessed with a computer simulation.

    PubMed

    Seedorf, Jens

    2013-09-01

    Livestock operations are under increasing pressure to fulfil minimum environmental requirements and avoid polluting the atmosphere. In regions with high farm animal densities, new farm buildings receive building permission only when biological exhaust air treatment systems (BEATS) are in place, such as biofilters. However, it is currently unknown whether BEATS can harbour pathogens such as zoonotic agents, which are potentially emitted via the purified gas. Because BEATS are located very close to the livestock building, it is assumed that BEATS-related microorganisms are aerially transported to farm animals via the inlet system of the ventilation system. To support this hypothesis, a computer simulation was applied to calculate the wind field around a facility consisting of a virtual livestock house and an adjacent biofilter. Under the chosen wind conditions (speed and direction), it can be shown that turbulences and eddies may occur in the near surrounding of a livestock building with an adjacent biofilter. Consequently, this might cause the entry of the released biofilter's purified gas into the barn, including possible microorganisms within this purified gas. If field investigations verify the results of the simulations, counter-measures must be taken to ensure biosecurity on farms with BEATS. © 2013 Society of Chemical Industry.

  8. SOLID STATE ENERGY CONVERSION ALLIANCE DELPHI SOLID OXIDE FUEL CELL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steven Shaffer; Sean Kelly; Subhasish Mukerjee

    2003-12-08

    The objective of Phase I under this project is to develop a 5 kW Solid Oxide Fuel Cell power system for a range of fuels and applications. During Phase I, the following will be accomplished: Develop and demonstrate technology transfer efforts on a 5 kW stationary distributed power generation system that incorporates steam reforming of natural gas with the option of piped-in water (Demonstration System A). Initiate development of a 5 kW system for later mass-market automotive auxiliary power unit application, which will incorporate Catalytic Partial Oxidation (CPO) reforming of gasoline, with anode exhaust gas injected into an ultra-lean burnmore » internal combustion engine. This technical progress report covers work performed by Delphi from January 1, 2003 to June 30, 2003, under Department of Energy Cooperative Agreement DE-FC-02NT41246. This report highlights technical results of the work performed under the following tasks: Task 1 System Design and Integration; Task 2 Solid Oxide Fuel Cell Stack Developments; Task 3 Reformer Developments; Task 4 Development of Balance of Plant (BOP) Components; Task 5 Manufacturing Development (Privately Funded); Task 6 System Fabrication; Task 7 System Testing; Task 8 Program Management; and Task 9 Stack Testing with Coal-Based Reformate.« less

  9. SOLID STATE ENERGY CONVERSION ALLIANCE DELPHI SOLID OXIDE FUEL CELL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steven Shaffer; Sean Kelly; Subhasish Mukerjee

    2004-05-07

    The objective of this project is to develop a 5 kW Solid Oxide Fuel Cell power system for a range of fuels and applications. During Phase I, the following will be accomplished: Develop and demonstrate technology transfer efforts on a 5 kW stationary distributed power generation system that incorporates steam reforming of natural gas with the option of piped-in water (Demonstration System A). Initiate development of a 5 kW system for later mass-market automotive auxiliary power unit application, which will incorporate Catalytic Partial Oxidation (CPO) reforming of gasoline, with anode exhaust gas injected into an ultra-lean burn internal combustion engine.more » This technical progress report covers work performed by Delphi from July 1, 2003 to December 31, 2003, under Department of Energy Cooperative Agreement DE-FC-02NT41246. This report highlights technical results of the work performed under the following tasks: Task 1 System Design and Integration; Task 2 Solid Oxide Fuel Cell Stack Developments; Task 3 Reformer Developments; Task 4 Development of Balance of Plant (BOP) Components; Task 5 Manufacturing Development (Privately Funded); Task 6 System Fabrication; Task 7 System Testing; Task 8 Program Management; Task 9 Stack Testing with Coal-Based Reformate; and Task 10 Technology Transfer from SECA CORE Technology Program. In this reporting period, unless otherwise noted Task 6--System Fabrication and Task 7--System Testing will be reported within Task 1 System Design and Integration. Task 8--Program Management, Task 9--Stack Testing with Coal Based Reformate, and Task 10--Technology Transfer from SECA CORE Technology Program will be reported on in the Executive Summary section of this report.« less

  10. Purex Plant comparison with 40 CFR 61, subpart H, and other referenced guidelines for the Product Removal (PR) (296-A-1) stack

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lohrasbi, J.

    Dose calculations for atmospheric radionuclide releases from the Hanford Site for calendar year (CY) 1992 were performed by Pacific Northwest Laboratory (PNL) using the approved US Environmental Protection Agency (EPA) CAP-88 computer model. Emissions from discharge points in the Hanford Site 100, 200, 300, 400, and 600 areas were calculated based on results of analyses of continuous and periodic sampling conducted at the discharge points. These calculated emissions were provided for inclusion in the CAP-88 model by area and by individual facility for those facilities having the potential to contribute more than 10 percent of the Hanford Site total ormore » to result in an impact of greater than 0.1 mrem per year to the maximally exposed individual (MEI). Also included in the assessment of offsite dose modeling are the measured radioactive emissions from all Hanford Site stacks that have routine monitoring performed. Record sampling systems have been installed on all stacks and vents that use exhaust fans to discharge air that potentially may carry airborne radioactivity. Estimation of activity from ingrowth of long-lived radioactive progeny is not included in the CAP-88 model; therefore, the Hanford Site GENII code (Napier et al. 1988) was used to supplement the CAP-88 dose calculations. When the dose to the MEI located in the Ringold area was calculated, the effective dose equivalent (EDE) from combined Hanford Site radioactive airborne emissions was shown to be 3.7E-03 mrem. This value was reported in the annual air emission report prepared for the Hanford Site (RL 1993).« less

  11. Dioxins, furans and polycyclic aromatic hydrocarbons emissions from a hospital and cemetery waste incinerator

    NASA Astrophysics Data System (ADS)

    Mininni, Giuseppe; Sbrilli, Andrea; Maria Braguglia, Camilla; Guerriero, Ettore; Marani, Dario; Rotatori, Mauro

    An experimental campaign was carried out on a hospital and cemetery waste incineration plant in order to assess the emissions of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs). Raw gases were sampled in the afterburning chamber, using a specifically designed device, after the heat recovery section and at the stack. Samples of slags from the combustion chamber and fly ashes from the bag filter were also collected and analyzed. PCDD/Fs and PAHs concentrations in exhaust gas after the heat exchanger (200-350 °C) decreased in comparison with the values detected in the afterburning chamber. Pollutant mass balance regarding the heat exchanger did not confirm literature findings about the de novo synthesis of PCDD/Fs in the heat exchange process. In spite of a consistent reduction of PCDD/Fs in the flue gas treatment system (from 77% up to 98%), the limit of 0.1 ng ITEQ Nm -3 at the stack was not accomplished. PCDD/Fs emission factors for air spanned from 2.3 up to 44 μg ITEQ t -1 of burned waste, whereas those through solid residues (mainly fly ashes) were in the range 41-3700 μg ITEQ t -1. Tests run with cemetery wastes generally showed lower PCDD/F emission factors than those with hospital wastes. PAH total emission factors (91-414 μg kg -1 of burned waste) were in the range of values reported for incineration of municipal and industrial wastes. In spite of the observed release from the scrubber, carcinogenic PAHs concentrations at the stack (0.018-0.5 μg Nm -3) were below the Italian limit of 10 μg Nm -3.

  12. Carbonyl compounds in dining areas, kitchens and exhaust streams in restaurants with varying cooking methods in Kaohsiung, Taiwan.

    PubMed

    Cheng, Jen-Hsuan; Lee, Yi-Shiun; Chen, Kang-Shin

    2016-03-01

    Eighteen carbonyl species in C1-C10 were measured in the dining areas, kitchens and exhaust streams of six different restaurant types in Kaohsiung, southern Taiwan. Measured results in the dining areas show that Japanese barbecue (45.06ppb) had the highest total carbonyl concentrations (sum of 18 compounds), followed by Chinese hotpot (38.21ppb), Chinese stir-frying (8.99ppb), Western fast-food (8.22ppb), Chinese-Western mixed style (7.38ppb), and Chinese buffet (3.08ppb), due to their different arrangements for dining and cooking spaces and different cooking methods. On average, low carbon-containing species (C1-C4), e.g., formaldehyde, acetaldehyde, acetone and butyraldehyde were dominant and contributed 55.01%-94.52% of total carbonyls in the dining areas of all restaurants. Meanwhile, Chinese-Western mixed restaurants (45.48ppb) had high total carbonyl concentrations in kitchens mainly because of its small kitchen and poor ventilation. However, high carbon-containing species (C5-C10) such as hexaldehyde, heptaldehyde and nonanaldehyde (16.62%-77.00% of total carbonyls) contributed comparatively with low carbon-containing compounds (23.01%-83.39% of total carbonyls) in kitchens. Furthermore, Chinese stir-frying (132.10ppb), Japanese barbecue (125.62ppb), Western fast-food (122.67ppb), and Chinese buffet (119.96ppb) were the four restaurant types with the highest total carbonyl concentrations in exhaust streams, indicating that stir-frying and grilling are inclined to produce polluted gases. Health risk assessments indicate that Chinese hotpot and Japanese barbecue exceeded the limits of cancer risk (10(-6)) and hazard index (=1), mainly due to high concentrations of formaldehyde. The other four restaurants were below both limits. Copyright © 2015. Published by Elsevier B.V.

  13. Surveillance of a Ventilated Rack System for Corynebacterium bovis by Sampling Exhaust-Air Manifolds.

    PubMed

    Manuel, Christopher A; Pugazhenthi, Umarani; Leszczynski, Jori K

    2016-01-01

    Corynebacterium bovis causes an opportunistic infection of nude (Foxn1, nu/nu) mice, leading to nude mouse hyperkeratotic dermatitis (scaly skin disease). Enzootic in many nude mouse colonies, C. bovis spreads rapidly to naive nude mice, despite modern husbandry practices, and is very difficult to eradicate. To facilitate rapid detection in support of eradication efforts, we investigated a surveillance method based on quantitative real-time PCR (qPCR) evaluation of swabs collected from the horizontal exhaust manifold (HEM) of an IVC rack system. We first evaluated the efficacy of rack sanitation methods for removing C. bovis DNA from the HEM of racks housing endemic colonies of infected nude mice. Pressurized water used to flush the racks' air exhaust system followed by a standard rack-washer cycle was ineffective in eliminating C. bovis DNA. Only after autoclaving did all sanitized racks test negative for C. bovis DNA. We then measured the effects of stage of infection (early or established), cage density, and cage location on the rack on time-to-detection at the HEM. Stage of infection significantly affected time-to-detection, independent of cage location. Early infections required 7.3 ± 1.2 d whereas established infections required 1 ± 0 d for detection of C. bovis at the HEM. Cage density influenced the quantity of C. bovis DNA detected but not time-to-detection. The location of the cage on the rack affected the time-to-detection only during early C. bovis infections. We suggest that qPCR swabs of HEM are useful during the routine surveillance of nude mouse colonies for C. bovis infection.

  14. Surveillance of a Ventilated Rack System for Corynebacterium bovis by Sampling Exhaust-Air Manifolds

    PubMed Central

    Manuel, Christopher A; Pugazhenthi, Umarani; Leszczynski, Jori K

    2016-01-01

    Corynebacterium bovis causes an opportunistic infection of nude (Foxn1, nu/nu) mice, leading to nude mouse hyperkeratotic dermatitis (scaly skin disease). Enzootic in many nude mouse colonies, C. bovis spreads rapidly to naive nude mice, despite modern husbandry practices, and is very difficult to eradicate. To facilitate rapid detection in support of eradication efforts, we investigated a surveillance method based on quantitative real-time PCR (qPCR) evaluation of swabs collected from the horizontal exhaust manifold (HEM) of an IVC rack system. We first evaluated the efficacy of rack sanitation methods for removing C. bovis DNA from the HEM of racks housing endemic colonies of infected nude mice. Pressurized water used to flush the racks’ air exhaust system followed by a standard rack-washer cycle was ineffective in eliminating C. bovis DNA. Only after autoclaving did all sanitized racks test negative for C. bovis DNA. We then measured the effects of stage of infection (early or established), cage density, and cage location on the rack on time-to-detection at the HEM. Stage of infection significantly affected time-to-detection, independent of cage location. Early infections required 7.3 ± 1.2 d whereas established infections required 1 ± 0 d for detection of C. bovis at the HEM. Cage density influenced the quantity of C. bovis DNA detected but not time-to-detection. The location of the cage on the rack affected the time-to-detection only during early C. bovis infections. We suggest that qPCR swabs of HEM are useful during the routine surveillance of nude mouse colonies for C. bovis infection. PMID:26817981

  15. On the Use of a Test to Exhaustion Specific to Tennis (TEST) with Ball Hitting by Elite Players

    PubMed Central

    2016-01-01

    Purpose We aimed to a) introduce a new Test to Exhaustion Specific to Tennis (TEST) and compare performance (test duration) and physiological responses to those obtained during the 20-m multistage shuttle test (MSST), and b) determine to which extent those variables correlate with performance level (tennis competitive ranking) for both test procedures. Methods Twenty-seven junior players (8 males, 19 females) members of the national teams of the French Tennis Federation completed MSST and TEST, including elements of the game (ball hitting, intermittent activity, lateral displacement), in a randomized order. Cardiorespiratory responses were compared at submaximal (respiratory compensation point) and maximal loads between the two tests. Results At the respiratory compensation point oxygen uptake (50.1 ± 4.7 vs. 47.5 ± 4.3 mL.min-1.kg-1, p = 0.02), but not minute ventilation and heart rate, was higher for TEST compared to MSST. However, load increment and physiological responses at exhaustion did not differ between the two tests. Players’ ranking correlated negatively with oxygen uptake measured at submaximal and maximal loads for both TEST (r = -0.41; p = 0.01 and -0.55; p = 0.004) and MSST (r = -0.38; P = 0.05 and -0.51; p = 0.1). Conclusion Using TEST provides a tennis-specific assessment of aerobic fitness and may be used to prescribe aerobic exercise in a context more appropriate to the game than MSST. Results also indicate that VO2 values both at submaximal and maximal load reached during TEST and MSST are moderate predictors of players competitive ranking. PMID:27035342

  16. Install Waste Heat Recovery Systems for Fuel-Fired Furnaces (English/Chinese) (Fact Sheet) (in Chinese; English)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Chinese translation of ITP fact sheet about installing Waste Heat Recovery Systems for Fuel-Fired Furnaces. For most fuel-fired heating equipment, a large amount of the heat supplied is wasted as exhaust or flue gases. In furnaces, air and fuel are mixed and burned to generate heat, some of which is transferred to the heating device and its load. When the heat transfer reaches its practical limit, the spent combustion gases are removed from the furnace via a flue or stack. At this point, these gases still hold considerable thermal energy. In many systems, this is the greatest single heat loss.more » The energy efficiency can often be increased by using waste heat gas recovery systems to capture and use some of the energy in the flue gas. For natural gas-based systems, the amount of heat contained in the flue gases as a percentage of the heat input in a heating system can be estimated by using Figure 1. Exhaust gas loss or waste heat depends on flue gas temperature and its mass flow, or in practical terms, excess air resulting from combustion air supply and air leakage into the furnace. The excess air can be estimated by measuring oxygen percentage in the flue gases.« less

  17. Characteristics of ammonia, hydrogen sulfide, carbon dioxide, and particulate matter concentrations in high-rise and manure-belt layer hen houses

    NASA Astrophysics Data System (ADS)

    Ni, Ji-Qin; Chai, Lilong; Chen, Lide; Bogan, Bill W.; Wang, Kaiying; Cortus, Erin L.; Heber, Albert J.; Lim, Teng-Teeh; Diehl, Claude A.

    2012-09-01

    Indoor air pollutants at high concentrations in poultry houses can potentially affect workers' health, and animal welfare and productivity. This paper presents research results of a 2-year continuous monitoring of ammonia (NH3), carbon dioxide (CO2), hydrogen sulfide (H2S), and particulate matter (PM) concentrations from to date the most comprehensive study on a single farm in two 180,000-bird high-rise (HR) and two 200,000-bird manure-belt (MB) layer hen houses located in Indiana, USA. Air was sampled at ventilation fans of the mechanically-ventilated houses. Concentrations of NH3 and CO2 were measured with photoacoustic multi-gas monitors. Concentrations of H2S and PM10 were monitored with pulsed fluorescence analyzers and Tapered Element Oscillating Microbalances (TEOM), respectively. The 2-year mean ± standard deviation concentrations at ventilation fans of the four layer hen houses were 48.9 ± 39 and 51.9 ± 40.7 ppm in HR, and 13.3 ± 9.1 and 12.9 ± 10.5 ppm in MB for NH3; 26.4 ± 17.6 and 24.9 ± 19 ppb in HR, 40.0 ± 21.1 and 41.2 ± 31.5 ppb in MB for H2S; 1755 ± 848 and 1804 ± 887 ppm in HR, and 2295 ± 871 and 2285 ± 946 ppm in MB for CO2; and 540 ± 303 and 552 ± 338 μg m-3 in HR, and 415 ± 428 and 761 ± 661 μg m-3 in MB for PM10. Compared with the MB houses, concentrations of the HR houses were higher for NH3, and lower for CO2, H2S, and PM10 (P < 0.05). High concentrations of NH3 detected in winter represent potential challenges to workers' health and animal welfare. Variations in pollutant concentrations at the exhaust fans were affected by outdoor temperature, ventilation, bird condition, and farm operation. A new weekly variation, characterized by significantly lower PM10 concentrations on Sundays, was identified and was related to the weekly schedule of house operational activities.

  18. Worker exposure to methanol vapors during cleaning of semiconductor wafers in a manufacturing setting.

    PubMed

    Gaffney, Shannon; Moody, Emily; McKinley, Meg; Knutsen, Jeffrey; Madl, Amy; Paustenbach, Dennis

    2008-05-01

    An exposure simulation was conducted to characterize methanol exposure of workers who cleaned wafers in quality control departments within the semiconductor industry. Short-term (15 min) and long-term (2-4 hr) personal and area samples (at distances of 1 m and 3-6 m from the source) were collected during the 2-day simulation. On the first day, 45 mL of methanol were used per hour by a single worker washing wafers in a 102 m(3) room with a ventilation rate of about 10 air changes per hour (ACH). Virtually all methanol volatilized. To assess exposures under conditions associated with higher productivity, on the second day, two workers cleaned wafers simultaneously, together using methanol at over twice the rate of the first day (95 mL/hr). On this day, the ventilation rate was halved (5 ACH). Personal concentrations on the first day averaged 60 ppm (SD = 46 ppm) and ranged from 10-140 ppm. On the second day, personal concentrations for both workers averaged 118 ppm (SD = 50 ppm; range: 64-270 ppm). Area concentrations measured on the first day at 1 m from the source and throughout the balance of the room averaged 29 ppm (SD = 19 ppm; range: 4-83 ppm) and 18 ppm (SD = 12 ppm; range: 3-42 ppm), respectively. As expected, area concentrations measured on the second day were higher than the first and averaged 73 ppm (SD = 25 ppm; range: 27-140 ppm) at 1 meter and 48 ppm (SD = 13 ppm; range: 21-67 ppm) throughout the balance of the room. The results of this simulation suggest that the use of methanol to clean semiconductor wafers without the use of local exhaust ventilation and with relatively low room ventilation rates is unlikely to result in worker exposures exceeding the current ACGIH(R) threshold limit value of 200 ppm. This study also confirmed prior studies suggesting that when a relatively volatile chemical is located within arm's length (near field), breathing zone concentrations will be about two- to threefold greater than the room concentration when the air exchange rate is 5-10 ACH.

  19. Perspective: Stochastic magnetic devices for cognitive computing

    NASA Astrophysics Data System (ADS)

    Roy, Kaushik; Sengupta, Abhronil; Shim, Yong

    2018-06-01

    Stochastic switching of nanomagnets can potentially enable probabilistic cognitive hardware consisting of noisy neural and synaptic components. Furthermore, computational paradigms inspired from the Ising computing model require stochasticity for achieving near-optimality in solutions to various types of combinatorial optimization problems such as the Graph Coloring Problem or the Travelling Salesman Problem. Achieving optimal solutions in such problems are computationally exhaustive and requires natural annealing to arrive at the near-optimal solutions. Stochastic switching of devices also finds use in applications involving Deep Belief Networks and Bayesian Inference. In this article, we provide a multi-disciplinary perspective across the stack of devices, circuits, and algorithms to illustrate how the stochastic switching dynamics of spintronic devices in the presence of thermal noise can provide a direct mapping to the computational units of such probabilistic intelligent systems.

  20. Control Techtronics International

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, J.

    1995-12-31

    Polish graded coal can be burned in existing stoker boilers and meet the 1998 Air Quality standard. This is accomplished with the Control Techtronics microprocessor-based combustion controller accurately and repeatedly: (a) matching the combustion air to the coal firing rate, with continuous stack sensor feedback; (b) continuously varying the boiler`s firing rate based on output water temperature or steam pressure; (c) continuously varying the exhaust fan`s speed to maintain minimum negative pressure in the boiler`s combustion chamber; and recirculating a portion of the flue gas, at varying amounts throughout the boiler`s firing rate. Systems for five boilers have been installedmore » and are operating on MPEC`s Balicka plant in Krakow. Control Techtronics International has $10 million of U.S. Export-Import Bank funds available for similar projects throughout Poland.« less