Predictors of outcome of prematurely born infants with pulmonary interstitial emphysema.
Williams, Emma; Dassios, Theodore; Clarke, Paul; Chowdhury, Olie; Greenough, Anne
2018-05-13
To determine how oxygenation, ventilation efficiency and tidal volume requirements changed with the development of pulmonary interstitial emphysema (PIE) and whether in affected patients a composite gas exchange index predicted death or bronchopulmonary dysplasia (BPD). Infants who developed PIE from 2010 to 2016 were identified. The oxygenation index, ventilation efficiency index, ventilation to perfusion ratio and inspiratory tidal volume were calculated before radiological evidence of PIE (pre-PIE) and at the worst PIE radiographic appearance (PIE-worst). Thirty infants, median (IQR) gestational age of 24.6 (24.3-26.7) weeks were assessed. Their age at pre-PIE was 11(6-19) days and 23 (13-42) days at PIE-worst. Compared to pre-PIE, at PIE-worst, the oxygenation index was higher [14.5 (10.7-19.2) versus 4.8 (3.1-6.1) respectively, p<0.001], ventilation efficiency index was lower [0.01 (0.01-0.11) versus 0.16 (0.13-0.19) respectively, p<0.001], ventilation to perfusion ratio was lower [0.15 (0.11-0.40) versus 0.26 (0.20-0.37), p=0.033] and tidal volume was higher [9.9 (7.2-13.1) versus 6.4 (5.5-6.8) ml/kg, p=0.007]. An oxygenation index >11.4 at PIE-worst predicted death or BPD with 80% sensitivity and 100% specificity. Development of PIE was associated with poorer oxygenation and ventilation efficiency despite increased tidal volumes. The oxygenation index at PIE-worst predicted death or BPD. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slosman, D.; Susskind, H.; Bossuyt, A.
1986-03-01
Ventilation imaging can be improved by gating scintigraphic data with the respiratory cycle using temporal Fourier analysis (TFA) to quantify the temporal behavior of the ventilation. Sixteen consecutive images, representing equal-time increments of an average respiratory cycle, were produced by TFA in the posterior view on a pixel-by-pixel basis. An Efficiency Index (EFF), defined as the ratio of the summation of all the differences between maximum and minimum counts for each pixel to that for the entire lung during the respiratory cycle, was derived to describe the pattern of ventilation. The gated ventilation studies were carried out with Xe-127 inmore » 12 subjects: normal lung function (4), small airway disease (2), COPD (5), and restrictive disease (1). EFF for the first three harmonics correlated linearly with FEV1 (r = 0.701, p< 0.01). This approach is suggested as a very sensitive method to quantify the extent and regional distribution of airway obstruction.« less
Mask Ventilation during Induction of General Anesthesia: Influences of Obstructive Sleep Apnea.
Sato, Shin; Hasegawa, Makoto; Okuyama, Megumi; Okazaki, Junko; Kitamura, Yuji; Sato, Yumi; Ishikawa, Teruhiko; Sato, Yasunori; Isono, Shiroh
2017-01-01
Depending on upper airway patency during anesthesia induction, tidal volume achieved by mask ventilation may vary. In 80 adult patients undergoing general anesthesia, the authors tested a hypothesis that tidal volume during mask ventilation is smaller in patients with sleep-disordered breathing priorly defined as apnea hypopnea index greater than 5 per hour. One-hand mask ventilation with a constant ventilator setting (pressure-controlled ventilation) was started 20 s after injection of rocuronium and maintained for 1 min during anesthesia induction. Mask ventilation efficiency was assessed by the breath number needed to initially exceed 5 ml/kg ideal body weight of expiratory tidal volume (primary outcome) and tidal volumes (secondary outcomes) during initial 15 breaths (UMIN000012494). Tidal volume progressively increased by more than 70% in 1 min and did not differ between sleep-disordered breathing (n = 42) and non-sleep-disordered breathing (n = 38) patients. In post hoc subgroup analyses, the primary outcome breath number (mean [95% CI], 5.7 [4.1 to 7.3] vs. 1.7 [0.2 to 3.2] breath; P = 0.001) and mean tidal volume (6.5 [4.6 to 8.3] vs. 9.6 [7.7 to 11.4] ml/kg ideal body weight; P = 0.032) were significantly smaller in 20 sleep-disordered breathing patients with higher apnea hypopnea index (median [25th to 75th percentile]: 21.7 [17.6 to 31] per hour) than in 20 non-sleep disordered breathing subjects with lower apnea hypopnea index (1.0 [0.3 to 1.5] per hour). Obesity and occurrence of expiratory flow limitation during one-hand mask ventilation independently explained the reduction of efficiency of mask ventilation, while the use of two hands effectively normalized inefficient mask ventilation during one-hand mask ventilation. One-hand mask ventilation is difficult in patients with obesity and severe sleep-disordered breathing particularly when expiratory flow limitation occurs during mask ventilation.
ENERGY STAR Certified Ventilating Fans
Certified models meet all ENERGY STAR requirements as listed in the Version 4.0 ENERGY STAR Program Requirements for Ventilating Fans that are effective as of October 1, 2015. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=vent_fans.pr_crit_vent_fans
Wolfson, Marla R; Hirschl, Ronald B; Jackson, J Craig; Gauvin, France; Foley, David S; Lamm, Wayne J E; Gaughan, John; Shaffer, Thomas H
2008-01-01
We performed a multicenter study to test the hypothesis that tidal liquid ventilation (TLV) would improve cardiopulmonary, lung histomorphological, and inflammatory profiles compared with conventional mechanical gas ventilation (CMV). Sheep were studied using the same volume-controlled, pressure-limited ventilator systems, protocols, and treatment strategies in three independent laboratories. Following baseline measurements, oleic acid lung injury was induced and animals were randomized to 4 hours of CMV or TLV targeted to "best PaO2" and PaCO2 35 to 60 mm Hg. The following were significantly higher (p < 0.01) during TLV than CMV: PaO2, venous oxygen saturation, respiratory compliance, cardiac output, stroke volume, oxygen delivery, ventilatory efficiency index; alveolar area, lung % gas exchange space, and expansion index. The following were lower (p < 0.01) during TLV compared with CMV: inspiratory and expiratory pause pressures, mean airway pressure, minute ventilation, physiologic shunt, plasma lactate, lung interleukin-6, interleukin-8, myeloperoxidase, and composite total injury score. No significant laboratories by treatment group interactions were found. In summary, TLV resulted in improved cardiopulmonary physiology at lower ventilatory requirements with more favorable histological and inflammatory profiles than CMV. As such, TLV offers a feasible ventilatory alternative as a lung protective strategy in this model of acute lung injury.
USDA-ARS?s Scientific Manuscript database
The thermal environment in poultry housing is a primary influence on production efficiency and live performance. Heavy broilers (body weight > 3.2 kg) typically require high ventilation rates to maintain thermal comfort and production efficiency. However, large birds are observed to pant in mild to ...
CPAP of 4 cm H(2)O Has no short-term benefit at term in infants with BPD.
Sandberg, Kenneth L; Hjalmarson, Ola
2012-01-01
Lung development and function is compromised at term in infants with bronchopulmonary dysplasia (BPD), characterized by reduced functional residual capacity (FRC) and impaired gas-mixing efficiency in distal airways. To determine whether continuous positive airway pressure (CPAP) improves FRC, ventilation, distal airway function, and gas exchange in spontaneously breathing infants with BPD. Twenty-one infants with BPD (median birth weight 0.72 kg (range 0.50-1.27) and median gestational age 26 weeks (range 23-28)) were studied before and after CPAP of 4 cm H(2)O was applied by a facemask system. A multiple-breath nitrogen washout method was used to assess FRC, ventilation, and gas-mixing efficiency. Moment analysis and lung clearance index was calculated from the nitrogen-decay curve for assessment of gas-mixing efficiency. Transcutaneous (Tc) PO(2)/PCO(2) was monitored during stable infant conditions before each washout test. When CPAP was raised from 0 to 4 cm H(2)O, FRC increased significantly together with a significant increase in moment ratios (M(1)/M(0) and M(2)/M(0)). Tc PO(2) decreased significantly and the breathing pattern changed, with significantly reduced respiratory rate, minute ventilation, and alveolar ventilation. There was also an increase in tidal volume and dead space. CPAP of 4 cm H(2)O applied with a facemask at term to infants with BPD did not improve ventilation, gas-mixing efficiency in distal airways, or oxygenation despite an increase in FRC. We speculate that instead of promoting recruitment of unventilated lung volumes, increasing the end-expiratory pressure in infants with BPD may lead to an overexpansion of already ventilated parts of the lung, causing further compromise of lung function. Copyright © 2012 S. Karger AG, Basel.
Effects of noninvasive ventilation on sleep outcomes in amyotrophic lateral sclerosis.
Katzberg, Hans D; Selegiman, Adam; Guion, Lee; Yuan, Nancy; Cho, Sungho C; Katz, Jonathan S; Miller, Robert G; So, Yuen T
2013-04-15
The objective was to study the effects on noninvasive ventilation on sleep outcomes in patient with ALS, specifically oxygenation and overall sleep quality. Patients with ALS who met criteria for initiation of NIV were studied with a series of 2 home PSG studies, one without NIV and a follow-up study while using NIV. Primary outcome was a change in the maximum overnight oxygen saturation; secondary outcomes included change in mean overnight oxygen saturation, apnea and hypopnea indexes, sleep latency, sleep efficiency, sleep arousals, and sleep architecture. A total of 94 patients with ALS were screened for eligibility; 15 were enrolled; and 12 completed study procedures. Maximum overnight oxygen saturation improved by 7.0% (p = 0.01) and by 6.7% during REM sleep (p = 0.02) with NIV. Time spent below 90% oxygen saturation was also significant-ly better with NIV (30% vs 19%, p < 0.01), and there was trend for improvement in mean overnight saturation (1.5%, p = 0.06). Apnea index (3.7 to 0.7), hypopnea index (6.2 to 5.7), and apnea hypopnea index (9.8 to 6.3) did not significantly improve after introducing NIV. NIV had no effect on sleep efficiency (mean change 10%), arousal index (7 to 12), or sleep stage distribution (Friedman chi-squared = 0.40). NIV improved oxygenation but showed no significant effects on sleep efficiency, sleep arousals, restful sleep, or sleep architecture. The net impact of these changes for patients deserves further study in a larger group of ALS patients.
Yehya, Nadir; Topjian, Alexis A; Thomas, Neal J; Friess, Stuart H
2014-05-01
Children with an immunocompromised condition and requiring invasive mechanical ventilation have high risk of death. Such patients are commonly transitioned to rescue modes of nonconventional ventilation, including airway pressure release ventilation and high-frequency oscillatory ventilation, for acute respiratory distress syndrome refractory to conventional ventilation. Our aim was to describe our experience with airway pressure release ventilation and high-frequency oscillatory ventilation in children with an immunocompromised condition and acute respiratory distress syndrome refractory to conventional ventilation and to identify factors associated with survival. Retrospective cohort study. Tertiary care, university-affiliated PICU. Sixty pediatric patients with an immunocompromised condition and acute respiratory distress syndrome refractory to conventional ventilation transitioned to either airway pressure release ventilation or high-frequency oscillatory ventilation. None. Demographic data, ventilator settings, arterial blood gases, oxygenation index, and PaO(2)/FIO(2) were recorded before transition to either mode of nonconventional ventilation and at predetermined intervals after transition for up to 5 days. Mortality in the entire cohort was 63% and did not differ between patients transitioned to airway pressure release ventilation and high-frequency oscillatory ventilation. For both airway pressure release ventilation and high-frequency oscillatory ventilation, improvements in oxygenation index and PaO(2)/FIO(2) at 24 hours expressed as a fraction of pretransition values (oxygenation index(24)/oxygenation index(pre) and PaO(2)/FIO(224)/PaO(2)/FIO(2pre)) reliably discriminated nonsurvivors from survivors, with receiver operating characteristic areas under the curves between 0.89 and 0.95 (p for all curves < 0.001). Sensitivity-specificity analysis suggested that less than 15% reduction in oxygenation index (90% sensitive, 75% specific) or less than 90% increase in PaO(2)/FIO(2) (80% sensitive, 94% specific) 24 hours after transition to airway pressure release ventilation were the optimal cutoffs to identify nonsurvivors. The comparable values 24 hours after transition to high-frequency oscillatory ventilation were less than 5% reduction in oxygenation index (100% sensitive, 83% specific) or less than 80% increase in PaO(2)/FIO(2) (91% sensitive, 89% specific) to identify nonsurvivors. In this single-center retrospective study of pediatric patients with an immunocompromised condition and acute respiratory distress syndrome failing conventional ventilation transitioned to either airway pressure release ventilation or high-frequency oscillatory ventilation, improved oxygenation at 24 hours expressed as PaO(2)/FIO(224)/PaO(2)/FIO(2pre) or oxygenation index(24)/oxygenation indexpre reliably discriminates nonsurvivors from survivors. These findings should be prospectively verified.
Assessment of Natural Ventilation System for a Typical Residential House in Poland
NASA Astrophysics Data System (ADS)
Antczak-Jarząbska, Romana; Krzaczek, Marek
2016-09-01
The paper presents the research results of field measurements campaign of natural ventilation performance and effectiveness in a residential building. The building is located in the microclimate whose parameters differ significantly in relation to a representative weather station. The measurement system recorded climate parameters and the physical variables characterizing the air flow in the rooms within 14 days of the winter season. The measurement results showed that in spite of proper design and construction of the ventilation system, unfavorable microclimatic conditions that differed from the predicted ones caused significant reduction in the efficiency of the ventilation system. Also, during some time periods, external climate conditions caused an opposite air flow direction in the vent inlets and outlets, leading to a significant deterioration of air quality and thermal comfort measured by CO2 concentration and PMV index in a residential area.
Corticosteroids and fetal intervention interact to alter lung maturation in preterm lambs.
Tabor, B L; Lewis, J F; Ikegami, M; Polk, D; Jobe, A H
1994-04-01
The relationship between cortisol infusion and time of fetal catheterization on postnatal lung function of prematurely delivered lambs was investigated with the hypothesis that the intervention of catheterization would alter fetal responsiveness to the maturational effects of corticosteroids. Fetal catheterization was performed on d 117 or on d 122 of gestation. Cortisol or saline control infusions were begun on d 126, with delivery 60 h later on d 128. The animals were ventilated for 1.25 h after delivery, and compliance, the ventilation efficiency index, labeled albumin leak into and out of the lungs, alveolar and lung saturated phosphatidylcholine and surfactant protein A were measured to evaluate lung performance and biochemical indicators of maturation. Cortisol improved compliance and ventilation efficiency and decreased labeled albumin recovery without changing alveolar saturated phosphatidylcholine or surfactant protein A in the animals catheterized at 122 d relative to 122-d saline-infused animals. However, the animals catheterized at 117 d and infused with saline were as mature as assessed by compliance and ventilation efficiency as the 122-d cortisol-treated animals. The 117-d cortisol-infused animals had significantly augmented lung function relative to either 117-d saline-infused or 122-d cortisol-treated lambs and were the only group that had increased alveolar surfactant protein A and lung saturated phosphatidylcholine pool sizes. This study demonstrates that the response of the fetal lung to a maturational agent such as cortisol is dependent on the history of previous fetal interventions.
Ventilatory Management During Normothermic Ex Vivo Lung Perfusion: Effects on Clinical Outcomes.
Terragni, Pier Paolo; Fanelli, Vito; Boffini, Massimo; Filippini, Claudia; Cappello, Paola; Ricci, Davide; Del Sorbo, Lorenzo; Faggiano, Chiara; Brazzi, Luca; Frati, Giacomo; Venuta, Federico; Mascia, Luciana; Rinaldi, Mauro; Ranieri, V Marco
2016-05-01
During ex vivo lung perfusion (EVLP), fixed ventilator settings and monitoring of compliance are used to prevent ventilator-induced lung injury (VILI). Analysis of the airway pressure-time curve (stress index) has been proposed to assess the presence of VILI. We tested whether currently proposed ventilator settings expose lungs to VILI during EVLP and whether the stress index could identify VILI better than compliance. Flow, volume, and airway opening pressure were collected continuously during EVLP. Durations of mechanical ventilation, intensive care unit (ICU) and hospital lengths of stay were recorded in lung recipients. Fourteen lungs underwent EVLP and were transplanted. In 5 lungs, 95 ± 2% of the stress index values were within the 0.95 to 1.05 range (protected); in the remaining nine lungs, 69 ± 1% of the values were greater than 1.05 and 15 ± 3% were less than 0.95 (nonprotected). There was a significant (P < 0.05) increase in cytokine concentrations after 4 hours of EVLP in the nonprotected lungs. Durations of mechanical ventilation, ICU, and hospital lengths of stay were shorter in recipients of protected than that of nonprotected lungs (P < 0.05). There was no correlation between compliance during EVLP and duration of mechanical ventilation or ICU and hospital lengths of stay in recipients, but the stress index during EVLP was significantly correlated with the duration of mechanical ventilation and with ICU and hospital lengths of stay (P < 0.05). This small, preliminary study shows that ventilator settings currently proposed for EVLP may expose lungs to VILI. Use of the stress index to personalize ventilator settings needs to be tested in further clinical studies.
Household ventilation and tuberculosis transmission in Kampala, Uganda.
Chamie, G; Wandera, B; Luetkemeyer, A; Bogere, J; Mugerwa, R D; Havlir, D V; Charlebois, E D
2013-06-01
To test the feasibility of measuring household ventilation and evaluate whether ventilation is associated with tuberculosis (TB) in household contacts in Kampala, Uganda. Adults with pulmonary TB and their household contacts received home visits to ascertain social and structural household characteristics. Ventilation was measured in air changes per hour (ACH) in each room by raising carbon dioxide (CO₂) levels using dry ice, removing the dry ice, and measuring changes in the natural log of CO₂ (lnCO2) over time. Ventilation was compared in homes with and without co-prevalent TB. Members of 61 of 66 (92%) households approached were enrolled. Households averaged 5.4 residents/home, with a median of one room/home. Twelve homes (20%) reported co-prevalent TB in household contacts. Median ventilation for all rooms was 14 ACH (interquartile range [IQR] 10-18). Median ventilation was 12 vs. 15 ACH in index cases' sleeping rooms in households with vs. those without co-prevalent TB (P = 0.12). Among smear-positive indexes not infected by the human immunodeficiency virus (HIV), median ventilation was 11 vs. 17 ACH in index cases' sleeping rooms in homes with vs. those without co-prevalent TB (P = 0.1). Our findings provide evidence that a simple CO₂ decay method used to measure ventilation in clinical settings can be adapted to homes, adding a novel tool and a neglected variable, ventilation, to the study of household TB transmission.
Hetzenecker, Andrea; Escourrou, Pierre; Kuna, Samuel T; Series, Frederic; Lewis, Keir; Birner, Christoph; Pfeifer, Michael; Arzt, Michael
2016-01-01
Impaired sleep efficiency is independently associated with worse prognosis in patients with chronic heart failure (CHF). Therefore, a test was conducted on whether auto-servo ventilation (ASV, biphasic positive airway pressure [BiPAP]-ASV, Philips Respironics) reduces sleep fragmentation and improves sleep efficiency in CHF patients with central sleep apnea (CSA) or obstructive sleep apnea (OSA). In this multicenter, randomized, parallel group trial, a study was conducted on 63 CHF patients (age 64 ± 10 years; left ventricular ejection fraction 29 ± 7%) with CSA or OSA (apnea-hypopnea Index, AHI 47 ± 18/h; 46% CSA) referred to sleep laboratories of the four participating centers. Participants were randomized to either ASV (n = 32) or optimal medical treatment alone (control, n = 31). Polysomnography (PSG) and actigraphy at home (home) with centralized blinded scoring were obtained at baseline and 12 weeks. ASV significantly reduced sleep fragmentation (total arousal indexPSG: -16.4 ± 20.6 vs. -0.6 ± 13.2/h, p = 0.001; sleep fragmentation indexhome: -7.6 ± 15.6 versus 4.3 ± 13.9/h, p = 0.003, respectively) and significantly increased sleep efficiency assessed by actigraphy (SEhome) compared to controls (2.3 ± 10.1 vs. -2.1 ± 6.9%, p = 0.002). Effects of ASV on sleep fragmentation and efficiency were similar in patients suffering from OSA and CSA. At home, ASV treatment modestly improves sleep fragmentation as well as sleep efficiency in CHF patients having either CSA or OSA. Copyright © 2015 Elsevier B.V. All rights reserved.
[Neurally adjusted ventilatory assist (NAVA). A new mode of assisted mechanical ventilation].
Moerer, O; Barwing, J; Quintel, M
2008-10-01
The aim of mechanical ventilation is to assure gas exchange while efficiently unloading the respiratory muscles and mechanical ventilation is an integral part of the care of patients with acute respiratory failure. Modern lung protective strategies of mechanical ventilation include low-tidal-volume ventilation and the continuation of spontaneous breathing which has been shown to be beneficial in reducing atelectasis and improving oxygenation. Poor patient-ventilator interaction is a major issue during conventional assisted ventilation. Neurally adjusted ventilator assist (NAVA) is a new mode of mechanical ventilation that uses the electrical activity of the diaphragm (EAdi) to control the ventilator. First experimental studies showed an improved patient-ventilator synchrony and an efficient unloading of the respiratory muscles. Future clinical studies will have to show that NAVA is of clinical advantage when compared to conventional modes of assisted mechanical ventilation. This review characterizes NAVA according to current publications on this topic.
Wallner, Peter; Munoz, Ute; Tappler, Peter; Wanka, Anna; Kundi, Michael; Shelton, Janie F; Hutter, Hans-Peter
2015-11-06
Energy-efficient buildings need mechanical ventilation. However, there are concerns that inadequate mechanical ventilation may lead to impaired indoor air quality. Using a semi-experimental field study, we investigated if exposure of occupants of two types of buildings (mechanical vs. natural ventilation) differs with regard to indoor air pollutants and climate factors. We investigated living and bedrooms in 123 buildings (62 highly energy-efficient and 61 conventional buildings) built in the years 2010 to 2012 in Austria (mainly Vienna and Lower Austria). Measurements of indoor parameters (climate, chemical pollutants and biological contaminants) were conducted twice. In total, more than 3000 measurements were performed. Almost all indoor air quality and room climate parameters showed significantly better results in mechanically ventilated homes compared to those relying on ventilation from open windows and/or doors. This study does not support the hypothesis that occupants in mechanically ventilated low energy houses are exposed to lower indoor air quality.
Natural ventilation of buildings: opposing wind and buoyancy
NASA Astrophysics Data System (ADS)
Linden, Paul; Hunt, Gary
1998-11-01
The use of natural ventilation in buildings is an attractive way to reduce energy usage thereby reducing costs and CO2 emissions. Generally, it is necessary to remove excess heat from a building and the designer can use the buoyancy forces associated with the above ambient temperatures within the building to drive a flow - 'stack' ventilation. The most efficient mode is displacement ventilation where warm air accumulates near the top of the building and flows out through upper level vents and cooler air flows in at lower levels. Ventilation will also be driven between these lower and upper openings by the wind. We report on laboratory modeling and theory which investigates the effects of an opposing wind on stack ventilation driven by a constant source of heat within a space under displacement ventilation. We show that there is a critical wind speed, expressed in dimensionless terms as a critical Froude number, above which displacement ventilation is replaced by (less efficient) mixing ventilation with reversed flow. Below this critical speed, displacement ventilation, in which the interior has a two-layer stratification, is maintained. The criterion for the change in ventilation mode is derived from general considerations of mixing efficiencies in stratified flows. We conclude that even when wind effects might appear to be dominant, the inhibition of mixing by the stable stratification within the space ensures that stack ventilation can operate over a wide range of apparently adverse conditions.
Night ventilation control strategies in office buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Zhaojun; Yi, Lingli; Gao, Fusheng
2009-10-15
In moderate climates night ventilation is an effective and energy-efficient approach to improve the indoor thermal environment for office buildings during the summer months, especially for heavyweight construction. However, is night ventilation a suitable strategy for office buildings with lightweight construction located in cold climates? In order to answer this question, the whole energy-consumption analysis software EnergyPlus was used to simulate the indoor thermal environment and energy consumption in typical office buildings with night mechanical ventilation in three cities in northern China. The summer outdoor climate data was analyzed, and three typical design days were chosen. The most important factorsmore » influencing night ventilation performance such as ventilation rates, ventilation duration, building mass and climatic conditions were evaluated. When night ventilation operation time is closer to active cooling time, the efficiency of night ventilation is higher. With night ventilation rate of 10 ach, the mean radiant temperature of the indoor surface decreased by up to 3.9 C. The longer the duration of operation, the more efficient the night ventilation strategy becomes. The control strategies for three locations are given in the paper. Based on the optimized strategies, the operation consumption and fees are calculated. The results show that more energy is saved in office buildings cooled by a night ventilation system in northern China than ones that do not employ this strategy. (author)« less
Lee, Sang Min; Seo, Joon Beom; Hwang, Hye Jeon; Kim, Namkug; Oh, Sang Young; Lee, Jae Seung; Lee, Sei Won; Oh, Yeon-Mok; Kim, Tae Hoon
2017-07-01
To compare the parenchymal attenuation change between inspiration/expiration CTs with dynamic ventilation change between xenon wash-in (WI) inspiration and wash-out (WO) expiration CTs. 52 prospectively enrolled COPD patients underwent xenon ventilation dual-energy CT during WI and WO periods and pulmonary function tests (PFTs). The parenchymal attenuation parameters (emphysema index (EI), gas-trapping index (GTI) and air-trapping index (ATI)) and xenon ventilation parameters (xenon in WI (Xe-WI), xenon in WO (Xe-WO) and xenon dynamic (Xe-Dyna)) of whole lung and three divided areas (emphysema, hyperinflation and normal) were calculated on virtual non-contrast images and ventilation images. Pearson correlation, linear regression analysis and one-way ANOVA were performed. EI, GTI and ATI showed a significant correlation with Xe-WI, Xe-WO and Xe-Dyna (EI R = -.744, -.562, -.737; GTI R = -.621, -.442, -.629; ATI R = -.600, -.421, -.610, respectively, p < 0.01). All CT parameters showed significant correlation with PFTs except forced vital capacity (FVC). There was a significant difference in GTI, ATI and Xe-Dyna in each lung area (p < 0.01). The parenchymal attenuation change between inspiration/expiration CTs and xenon dynamic change between xenon WI- and WO-CTs correlate significantly. There are alterations in the dynamics of xenon ventilation between areas of emphysema. • The xenon ventilation change correlates with the parenchymal attenuation change. • The xenon ventilation change shows the difference between three lung areas. • The combination of attenuation and xenon can predict more accurate PFTs.
Home energy efficiency and radon related risk of lung cancer: modelling study
Milner, James; Shrubsole, Clive; Das, Payel; Jones, Benjamin; Ridley, Ian; Chalabi, Zaid; Hamilton, Ian; Armstrong, Ben; Davies, Michael
2014-01-01
Objective To investigate the effect of reducing home ventilation as part of household energy efficiency measures on deaths from radon related lung cancer. Design Modelling study. Setting England. Intervention Home energy efficiency interventions, motivated in part by targets for reducing greenhouse gases, which entail reduction in uncontrolled ventilation in keeping with good practice guidance. Main outcome measures Modelled current and future distributions of indoor radon levels for the English housing stock and associated changes in life years due to lung cancer mortality, estimated using life tables. Results Increasing the air tightness of dwellings (without compensatory purpose-provided ventilation) increased mean indoor radon concentrations by an estimated 56.6%, from 21.2 becquerels per cubic metre (Bq/m3) to 33.2 Bq/m3. After the lag in lung cancer onset, this would result in an additional annual burden of 4700 life years lost and (at peak) 278 deaths. The increases in radon levels for the millions of homes that would contribute most of the additional burden are below the threshold at which radon remediation measures are cost effective. Fitting extraction fans and trickle ventilators to restore ventilation will help offset the additional burden but only if the ventilation related energy efficiency gains are lost. Mechanical ventilation systems with heat recovery may lower radon levels and the risk of cancer while maintaining the advantage of energy efficiency for the most airtight dwellings but there is potential for a major adverse impact on health if such systems fail. Conclusion Unless specific remediation is used, reducing the ventilation of dwellings will improve energy efficiency only at the expense of population wide adverse impact on indoor exposure to radon and risk of lung cancer. The implications of this and other consequences of changes to ventilation need to be carefully evaluated to ensure that the desirable health and environmental benefits of home energy efficiency are not compromised by avoidable negative impacts on indoor air quality. PMID:24415631
Itagaki, Taiga; Bennett, Desmond J; Chenelle, Christopher T; Fisher, Daniel F; Kacmarek, Robert M
2017-01-01
Volume-targeted ventilation is increasingly used in low birthweight infants because of the potential for reducing volutrauma and avoiding hypocapnea. However, it is not known what level of air leak is acceptable during neonatal volume-targeted ventilation when leak compensation is activated concurrently. Four ICU ventilators (Servo-i, PB980, V500, and Avea) were compared in available invasive volume-targeted ventilation modes (pressure control continuous spontaneous ventilation [PC-CSV] and pressure control continuous mandatory ventilation [PC-CMV]). The Servo-i and PB980 were tested with (+) and without (-) their proximal flow sensor. The V500 and Avea were tested with their proximal flow sensor as indicated by their manufacturers. An ASL 5000 lung model was used to simulate 4 neonatal scenarios (body weight 0.5, 1, 2, and 4 kg). The ASL 5000 was ventilated via an endotracheal tube with 3 different leaks. Two minutes of data were collected after each change in leak level, and the asynchrony index was calculated. Tidal volume (V T ) before and after the change in leak was assessed. The differences in delivered V T between before and after the change in leak were within ±5% in all scenarios with the PB980 (-/+) and V500. With the Servo-i (-/+), baseline V T was ≥10% greater than set V T during PC-CSV, and delivered V T markedly changed with leak. The Avea demonstrated persistent high V T in all leak scenarios. Across all ventilators, the median asynchrony index was 1% (interquartile range 0-27%) in PC-CSV and 1.8% (0-45%) in PC-CMV. The median asynchrony index was significantly higher in the Servo-i (-/+) than in the PB980 (-/+) and V500 in 1 and 2 kg scenarios during PC-CSV and PC-CMV. The PB980 and V500 were the only ventilators to acclimate to all leak scenarios and achieve targeted V T . Further clinical investigation is needed to validate the use of leak compensation during neonatal volume-targeted ventilation. Copyright © 2017 by Daedalus Enterprises.
Schädlich, S; Königs, I; Kalbitz, F; Blankenburg, T; Busse, H-J; Schütte, W
2004-06-01
Cheyne-Stokes respiration (CSR) is known to be an important negative predictor of outcome in patients with congestive heart failure. The goal of this study was to investigate whether the use of adaptive servo ventilation (AutoSet CS) would permit sufficient suppression of this pathological breathing pattern and improve cardiac function in longterm use over 1 year. Inclusion criteria for the study were congestive heart failure (left ventricular ejection fraction 20-50%), proven CSR with a central apnea-hypopnea index (AHI) > 15/h and stable clinical status with standard medical therapy. Patients with obstructive sleep apnea and COPD were excluded. Twenty consecutive patients (16 male) age 65.5 years (range 48-77) were followed with full blood counts, blood gas analysis, lung function tests and questionnaires for cardiopulmonary capacities (Minnesota, MRC Scale) and sleepiness (Epworth Sleepiness Scale). In addition, we performed 6-min walk distance (6MWD), echocardiography and polysomnography just before and after adjusting to adaptive servo ventilation and 3 and 12 months later. Mean usage of adaptive servo ventilation was sufficient (4.3 +/- 2.1 h/day at 12 months). No significant changes in blood gas analysis, blood counts and pulmonary function were detectable. CSR disappeared almost completely in all patients (AHI pre-study 44.3 +/- 13.4/h vs 3.4 +/- 8.0/h at 12 months; p < 0.0001). Saturation normalized steadily over the course of the study. The desaturation index decreased from 45.3 +/- 17.8/h to 5.2 +/- 11.5/h at 12 months (p < 0.0001). Mean saturation increased with the first night of sleep with adaptive servo ventilation from 92.0 +/- 2.5% to 93.0 +/- 1.6% (p < 0.05) and then to 94.1 +/- 1.9% at 3, and 94.2 +/- 1.9% at 12 months (p < 0.001). Quality of sleep was significantly improved with an increase of slow-wave sleep from 4.5 +/- 4.6% to 13.7 +/- 6.9% at 12 months (p < 0.0001). The arousal index concomitantly decreased from 29.8 +/- 17.9/h pre-study to 12.0 +/- 10.3/h at 12 months (p < 0.01). REM-sleep and sleep efficiency remained unchanged. The Epworth Sleepiness Scale showed only a trend to improvement. Cardiac function improved significantly during the course of the study. The ejection fraction increased from mean 37.1 +/- 12.5% pre-study to 41.7 +/- 8.8% at 12 months (p < 0.05). The 6-min walk distance increased from 192 +/- 110 m to 277 +/- 130 m at 12 months (p < 0.01). The MRC and Minnesota score were not significantly different pre- and post-study. We conclude that long-term respirator therapy with adaptive servo ventilation has sufficiently suppressed CSR and improved cardiac function in patients with congestive heart failure. Thus, safety and feasibility of this respirator therapy could be demonstrated. However, due to methodological reasons (no control group, no randomization) a direct effect on cardiac function could not be confirmed.
Design and Development of a Regenerative Blower for EVA Suit Ventilation
NASA Technical Reports Server (NTRS)
Izenson, Michael G.; Chen, Weibo; Hill, Roger W.; Phillips, Scott D.; Paul, Heather L.
2011-01-01
Ventilation subsystems in future space suits require a dedicated ventilation fan. The unique requirements for the ventilation fan - including stringent safety requirements and the ability to increase output to operate in buddy mode - combine to make a regenerative blower an attractive choice. This paper describes progress in the design, development, and testing of a regenerative blower designed to meet requirements for ventilation subsystems in future space suits. We have developed analysis methods for the blower s complex, internal flows and identified impeller geometries that enable significant improvements in blower efficiency. We verified these predictions by test, measuring aerodynamic efficiencies of 45% at operating conditions that correspond to the ventilation fan s design point. We have developed a compact motor/controller to drive the blower efficiently at low rotating speed (4500 rpm). Finally, we have assembled a low-pressure oxygen test loop to demonstrate the blower s reliability under prototypical conditions.
Nagano, Osamu; Yumoto, Tetsuya; Nishimatsu, Atsunori; Kanazawa, Shunsuke; Fujita, Takahisa; Asaba, Sunao; Yamanouchi, Hideo
2018-04-19
Bias flow (BF) is essential to maintain mean airway pressure (MAP) and to washout carbon dioxide (CO 2 ) from the oscillator circuit during high-frequency oscillatory ventilation (HFOV). If the BF rate is inadequate, substantial CO 2 rebreathing could occur and ventilation efficiency could worsen. With lower ventilation efficiency, the required stroke volume (SV) would increase in order to obtain the same alveolar ventilation with constant frequency. The aim of this study was to assess the effect of BF rate on ventilation efficiency during adult HFOV. The R100 oscillator (Metran, Japan) was connected to an original lung model internally equipped with a simulated bronchial tree. The actual SV was measured with a flow sensor placed at the Y-piece. Carbon dioxide (CO 2 ) was continuously insufflated into the lung model ([Formula: see text]CO 2 ), and the partial pressure of CO 2 (PCO 2 ) in the lung model was monitored. Alveolar ventilation ([Formula: see text]A) was estimated as [Formula: see text]CO 2 divided by the stabilized value of PCO 2 . [Formula: see text]A was evaluated by setting SV from 80 to 180 mL (10 mL increments, n = 5) at a frequency of 8 Hz, a MAP of 25 cmH 2 O, and a BF of 10, 20, 30, and 40 L/min (study 1). Ventilation efficiency was calculated as [Formula: see text]A divided by the actual minute volume. The experiment was also performed with an actual SV of 80, 100, and 120 mL and a BF from 10 to 60 L/min (10 L/min increments: study 2). Study 1: With the same setting SV, the [Formula: see text]A with a BF of 20 L/min or more was significantly higher than that with a BF of 10 L/min. Study 2: With the same actual SV, the [Formula: see text]A and the ventilation efficiency with a BF of 30 L/min or more were significantly higher than those with a BF of 10 or 20 L/min. Increasing BF up to 30 L/min or more improved ventilation efficiency in the R100 oscillator.
Zhang, Xianming; Du, Juan; Wu, Weiliang; Zhu, Yongcheng; Jiang, Ying; Chen, Rongchang
2017-01-01
In spite of intensive investigations, the role of spontaneous breathing (SB) activity in ARDS has not been well defined yet and little has been known about the different contribution of inspiratory or expiratory muscles activities during mechanical ventilation in patients with ARDS. In present study, oleic acid-induced beagle dogs’ ARDS models were employed and ventilated with the same level of mean airway pressure. Respiratory mechanics, lung volume, gas exchange and inflammatory cytokines were measured during mechanical ventilation, and lung injury was determined histologically. As a result, for the comparable ventilator setting, preserved inspiratory muscles activity groups resulted in higher end-expiratory lung volume (EELV) and oxygenation index. In addition, less lung damage scores and lower levels of system inflammatory cytokines were revealed after 8 h of ventilation. In comparison, preserved expiratory muscles activity groups resulted in lower EELV and oxygenation index. Moreover, higher lung injury scores and inflammatory cytokines levels were observed after 8 h of ventilation. Our findings suggest that the activity of inspiratory muscles has beneficial effects, whereas that of expiratory muscles exerts adverse effects during mechanical ventilation in ARDS animal model. Therefore, for mechanically ventilated patients with ARDS, the demands for deep sedation or paralysis might be replaced by the strategy of expiratory muscles paralysis through epidural anesthesia. PMID:28230150
Assessing values of air quality and visibility at risk from wildland fires.
Sue A. Ferguson; Steven J. McKay; David E. Nagel; Trent Piepho; Miriam L. Rorig; Casey Anderson; Lara Kellogg
2003-01-01
To assess values of air quality and visibility at risk from wildland fire in the United States, we generated a 40-year database that includes twice daily values of wind, mixing height, and a ventilation index that is the product of windspeed and mixing height. The database provides the first nationally consistent map of surface wind and ventilation index. In addition,...
Contaminants in ventilated filling boxes
NASA Astrophysics Data System (ADS)
Bolster, D. T.; Linden, P. F.
While energy efficiency is important, the adoption of energy-efficient ventilation systems still requires the provision of acceptable indoor air quality. Many low-energy systems, such as displacement or natural ventilation, rely on temperature stratification within the interior environment, always extracting the warmest air from the top of the room. Understanding buoyancy-driven convection in a confined ventilated space is key to understanding the flow that develops with many of these modern low-energy ventilation schemes. In this work we study the transport of an initially uniformly distributed passive contaminant in a displacement-ventilated space. Representing a heat source as an ideal sourced of buoyancy, analytical and numerical models are developed that allow us to compare the average efficiency of contaminant removal between traditional mixing and modern low-energy systems. A set of small-scale analogue laboratory experiments was also conducted to further validate our analytical and numerical solutions.We find that on average traditional and low-energy ventilation methods are similar with regard to pollutant flushing efficiency. This is because the concentration being extracted from the system at any given time is approximately the same for both systems. However, very different vertical concentration gradients exist. For the low-energy system, a peak in contaminant concentration occurs at the temperature interface that is established within the space. This interface is typically designed to sit at some intermediate height in the space. Since this peak does not coincide with the extraction point, displacement ventilation does not offer the same benefits for pollutant flushing as it does for buoyancy removal.
Dynamic airway pressure-time curve profile (Stress Index): a systematic review.
Terragni, Pierpaolo; Bussone, Guido; Mascia, Luciana
2016-01-01
The assessment of respiratory mechanics at the bedside is necessary in order to identify the most protective ventilatory strategy. Indeed in the last 20 years, adverse effects of positive ventilation to the lung structures have led to a reappraisal of the objectives of mechanical ventilation. The ventilator setting requires repeated readjustment over the period of mechanical ventilation dependency and careful respiratory monitoring to minimize the risks, preventing further injury and permitting the lung and airways healing. Among the different methods that have been proposed and validated, the analysis of dynamic P-t curve (named Stress Index, SI) represents an adequate tool available at the bedside, repeatable and, therefore, able to identify the amount of overdistension occurring in the daily clinical practice, when modifying positive end-expiratory pressure. In this review we will analyze the evidence that supports respiratory mechanics assessment at the bedside and the application of the dynamic P/t curve profile (SI) to optimize protective ventilation in patients with acute respiratory failure.
Ortega, Isabel Cristina Muñoz; Valdivieso, Alher Mauricio Hernández; Lopez, Joan Francesc Alonso; Villanueva, Miguel Ángel Mañanas; Lopez, Luis Horacio Atehortúa
2017-01-01
Objective The aim of this pilot study was to evaluate the feasibility of surface electromyographic signal derived indexes for the prediction of weaning outcomes among mechanically ventilated subjects after cardiac surgery. Methods A sample of 10 postsurgical adult subjects who received cardiovascular surgery that did not meet the criteria for early extubation were included. Surface electromyographic signals from diaphragm and ventilatory variables were recorded during the weaning process, with the moment determined by the medical staff according to their expertise. Several indexes of respiratory muscle expenditure from surface electromyography using linear and non-linear processing techniques were evaluated. Two groups were compared: successfully and unsuccessfully weaned patients. Results The obtained indexes allow estimation of the diaphragm activity of each subject, showing a correlation between high expenditure and weaning test failure. Conclusion Surface electromyography is becoming a promising procedure for assessing the state of mechanically ventilated patients, even in complex situations such as those that involve a patient after cardiovascular surgery. PMID:28977261
Short-term airing by natural ventilation - implication on IAQ and thermal comfort.
Heiselberg, P; Perino, M
2010-04-01
The need to improve the energy efficiency of buildings requires new and more efficient ventilation systems. It has been demonstrated that innovative operating concepts that make use of natural ventilation seem to be more appreciated by occupants. Among the available ventilation strategies that are currently available, buoyancy driven, single-sided natural ventilation has proved to be very effective and can provide high air change rates for temperature and Indoor Air Quality (IAQ) control. However, to promote a wider distribution of these systems an improvement in the knowledge of their working principles is necessary. The present study analyses and presents the results of an experimental evaluation of airing performance in terms of ventilation characteristics, IAQ and thermal comfort. It includes investigations of the consequences of opening time, opening frequency, opening area and expected airflow rate, ventilation efficiency, thermal comfort and dynamic temperature conditions. A suitable laboratory test rig was developed to perform extensive experimental analyses of the phenomenon under controlled and repeatable conditions. The results showed that short-term window airing is very effective and can provide both acceptable IAQ and thermal comfort conditions in buildings. Practical Implications This study gives the necessary background and in-depth knowledge of the performance of window airing by single-sided natural ventilation necessary for the development of control strategies for window airing (length of opening period and opening frequency) for optimum IAQ and thermal comfort in naturally ventilated buildings.
FRACTIONAL AEROSOL FILTRATION EFFICIENCY OF IN-DUCT VENTILATION AIR CLEANERS
The filtration efficiency of ventilation air cleaners is highly particle-size dependent over the 0.01 to 3 μm diameter size range. Current standardized test methods, which determine only overall efficiencies for ambient aerosol or other test aerosols, provide data of limited util...
Bechard, Lori J; Duggan, Christopher; Touger-Decker, Riva; Parrott, J Scott; Rothpletz-Puglia, Pamela; Byham-Gray, Laura; Heyland, Daren; Mehta, Nilesh M
2016-08-01
To determine the influence of admission anthropometry on clinical outcomes in mechanically ventilated children in the PICU. Data from two multicenter cohort studies were compiled to examine the unique contribution of nutritional status, defined by body mass index z score, to 60-day mortality, hospital-acquired infections, length of hospital stay, and ventilator-free days, using multivariate analysis. Ninety PICUs from 16 countries with eight or more beds. Children aged 1 month to 18 years, admitted to each participating PICU and requiring mechanical ventilation for more than 48 hours. Data from 1,622 eligible patients, 54.8% men and mean (SD) age 4.5 years (5.1), were analyzed. Subjects were classified as underweight (17.9%), normal weight (54.2%), overweight (14.5%), and obese (13.4%) based on body mass index z score at admission. After adjusting for severity of illness and site, the odds of 60-day mortality were higher in underweight (odds ratio, 1.53; p < 0.001) children. The odds of hospital-acquired infections were higher in underweight (odds ratio, 1.88; p = 0.008) and obese (odds ratio, 1.64; p < 0.001) children. Hazard ratios for hospital discharge were lower among underweight (hazard ratio, 0.71; p < 0.001) and obese (hazard ratio, 0.82; p = 0.04) children. Underweight was associated with 1.3 (p = 0.001) and 1.6 (p < 0.001) fewer ventilator-free days than normal weight and overweight, respectively. Malnutrition is prevalent in mechanically ventilated children on admission to PICUs worldwide. Classification as underweight or obese was associated with higher risk of hospital-acquired infections and lower likelihood of hospital discharge. Underweight children had a higher risk of mortality and fewer ventilator-free days.
Ohno, Yoshiharu; Fujisawa, Yasuko; Takenaka, Daisuke; Kaminaga, Shigeo; Seki, Shinichiro; Sugihara, Naoki; Yoshikawa, Takeshi
2018-02-01
The objective of this study was to compare the capability of xenon-enhanced area-detector CT (ADCT) performed with a subtraction technique and coregistered 81m Kr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity in smokers. Forty-six consecutive smokers (32 men and 14 women; mean age, 67.0 years) underwent prospective unenhanced and xenon-enhanced ADCT, 81m Kr-ventilation SPECT/CT, and pulmonary function tests. Disease severity was evaluated according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification. CT-based functional lung volume (FLV), the percentage of wall area to total airway area (WA%), and ventilated FLV on xenon-enhanced ADCT and SPECT/CT were calculated for each smoker. All indexes were correlated with percentage of forced expiratory volume in 1 second (%FEV 1 ) using step-wise regression analyses, and univariate and multivariate logistic regression analyses were performed. In addition, the diagnostic accuracy of the proposed model was compared with that of each radiologic index by means of McNemar analysis. Multivariate logistic regression showed that %FEV 1 was significantly affected (r = 0.77, r 2 = 0.59) by two factors: the first factor, ventilated FLV on xenon-enhanced ADCT (p < 0.0001); and the second factor, WA% (p = 0.004). Univariate logistic regression analyses indicated that all indexes significantly affected GOLD classification (p < 0.05). Multivariate logistic regression analyses revealed that ventilated FLV on xenon-enhanced ADCT and CT-based FLV significantly influenced GOLD classification (p < 0.0001). The diagnostic accuracy of the proposed model was significantly higher than that of ventilated FLV on SPECT/CT (p = 0.03) and WA% (p = 0.008). Xenon-enhanced ADCT is more effective than 81m Kr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity.
Lanspa, Michael J.; Grissom, Colin K.; Hirshberg, Eliotte L.; Jones, Jason P.; Brown, Samuel M.
2013-01-01
Background Volume expansion is a mainstay of therapy in septic shock, although its effect is difficult to predict using conventional measurements. Dynamic parameters, which vary with respiratory changes, appear to predict hemodynamic response to fluid challenge in mechanically ventilated, paralyzed patients. Whether they predict response in patients who are free from mechanical ventilation is unknown. We hypothesized that dynamic parameters would be predictive in patients not receiving mechanical ventilation. Methods This is a prospective, observational, pilot study. Patients with early septic shock and who were not receiving mechanical ventilation received 10 ml/kg volume expansion (VE) at their treating physician's discretion after initial resuscitation in the emergency department. We used transthoracic echocardiography to measure vena cava collapsibility index (VCCI) and aortic velocity variation (AoVV) prior to VE. We used a pulse contour analysis device to measure stroke volume variation (SVV). Cardiac index was measured immediately before and after VE using transthoracic echocardiography. Hemodynamic response was defined as an increase in cardiac index ≥ 15%. Results 14 patients received VE, 5 of which demonstrated a hemodynamic response. VCCI and SVV were predictive (Area under curve = 0.83, 0.92, respectively). Optimal thresholds were calculated: VCCI ≥ 15% (Positive predictive value, PPV 62%, negative predictive value, NPV 100%, p = 0.03); SVV ≥ 17% (PPV 100%, NPV 82%, p = 0.03). AoVV was not predictive. Conclusions VCCI and SVV predict hemodynamic response to fluid challenge patients with septic shock who are not mechanically ventilated. Optimal thresholds differ from those described in mechanically ventilated patients. PMID:23324885
NASA Astrophysics Data System (ADS)
Czaplik, Michael; Biener, Ingeborg; Leonhardt, Steffen; Rossaint, Rolf
2014-03-01
Since mechanical ventilation can cause harm to lung tissue it should be as protective as possible. Whereas numerous options exist to set ventilator parameters, an adequate monitoring is lacking up to date. The Electrical Impedance Tomography (EIT) provides a non-invasive visualization of ventilation which is relatively easy to apply and commercially available. Although there are a number of published measures and parameters derived from EIT, it is not clear how to use EIT to improve clinical outcome of e.g. patients suffering from acute respiratory distress syndrome (ARDS), a severe disease with a high mortality rate. On the one hand, parameters should be easy to obtain, on the other hand clinical algorithms should consider them to optimize ventilator settings. The so called Global inhomogeneity (GI) index bases on the fact that ARDS is characterized by an inhomogeneous injury pattern. By applying positive endexpiratory pressures (PEEP), homogeneity should be attained. In this study, ARDS was induced by a double hit procedure in six pigs. They were randomly assigned to either the EIT or the control group. Whereas in the control group the ARDS network table was used to set the PEEP according to the current inspiratory oxygen fraction, in the EIT group the GI index was calculated during a decremental PEEP trial. PEEP was kept when GI index was lowest. Interestingly, PEEP was significantly higher in the EIT group. Additionally, two of these animals died ahead of the schedule. Obviously, not only homogeneity of ventilation distribution matters but also limitation of over-distension.
Sachdev, Anil; Chugh, Krishan; Raghunathan, Veena; Gupta, Dhiren; Wattal, Chand; Menon, Geetha R
2013-01-01
To evaluate the reproducibility of blind bronchial sampling in patients with suspected diagnosis of bacterial ventilator-associated pneumonia. Prospective study. Pediatric intensive care unit of a tertiary care, multidisciplinary, teaching hospital in Northern India. All consecutive patients on mechanical ventilation for >48 hrs were evaluated clinically for ventilator-associated pneumonia. Children with clinical ventilator-associated pneumonia were subjected to blind bronchial sampling twice. Sixty-eight blind bronchial sampling samples from 34 patients were analyzed for polymorphonuclear cells, the presence, type, and number of bacteria. Acinetobacter baumannii was the most common organism grown from distal respiratory secretions. For polymorphonuclear cells, the concordance between two blind bronchial samples was 85.3% and kappa coefficient was 0.65. The concordance for the presence and type of bacteria in Gram staining in two samples was 85.3% and kappa coefficient was 0.68. The intraclass coefficients for bacterial index and predominant species index were 0.82 (95% confidence interval 0.65-0.91) and 0.89 (95% confidence interval 0.78-0.94), respectively. The use of prior antibiotics did not adversely affect the reproducibility of blind bronchial sampling. No major complications were recorded during the procedure. Blind bronchial sampling of lower respiratory tract secretions in mechanically ventilated patients generates reproducible results of quantitative and qualitative cultures. We suggest that blind bronchial sampling may provide valuable clue to the bacterial etiology in ventilated child with suspected clinical ventilator-associated pneumonia.
2012-01-01
Background Hyperpolarised helium MRI (He3 MRI) is a new technique that enables imaging of the air distribution within the lungs. This allows accurate determination of the ventilation distribution in vivo. The technique has the disadvantages of requiring an expensive helium isotope, complex apparatus and moving the patient to a compatible MRI scanner. Electrical impedance tomography (EIT) a non-invasive bedside technique that allows constant monitoring of lung impedance, which is dependent on changes in air space capacity in the lung. We have used He3MRI measurements of ventilation distribution as the gold standard for assessment of EIT. Methods Seven rats were ventilated in supine, prone, left and right lateral position with 70% helium/30% oxygen for EIT measurements and pure helium for He3 MRI. The same ventilator and settings were used for both measurements. Image dimensions, geometric centre and global in homogeneity index were calculated. Results EIT images were smaller and of lower resolution and contained less anatomical detail than those from He3 MRI. However, both methods could measure positional induced changes in lung ventilation, as assessed by the geometric centre. The global in homogeneity index were comparable between the techniques. Conclusion EIT is a suitable technique for monitoring ventilation distribution and inhomgeneity as assessed by comparison with He3 MRI. PMID:22966835
Gas exchange and intrapulmonary distribution of ventilation during continuous-flow ventilation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vettermann, J.; Brusasco, V.; Rehder, K.
1988-05-01
In 12 anesthetized paralyzed dogs, pulmonary gas exchange and intrapulmonary inspired gas distribution were compared between continuous-flow ventilation (CFV) and conventional mechanical ventilation (CMV). Nine dogs were studied while they were lying supine, and three dogs were studied while they were lying prone. A single-lumen catheter for tracheal insufflation and a double-lumen catheter for bilateral endobronchial insufflation (inspired O2 fraction = 0.4; inspired minute ventilation = 1.7 +/- 0.3 (SD) 1.kg-1.min-1) were evaluated. Intrapulmonary gas distribution was assessed from regional 133Xe clearances. In dogs lying supine, CO2 elimination was more efficient with endobronchial insufflation than with tracheal insufflation, but themore » alveolar-arterial O2 partial pressure difference was larger during CFV than during CMV, regardless of the type of insufflation. By contrast, endobronchial insufflation maintained both arterial PCO2 and alveolar-arterial O2 partial pressure difference at significantly lower levels in dogs lying prone than in dogs lying supine. In dogs lying supine, the dependent lung was preferentially ventilated during CMV but not during CFV. In dogs lying prone, gas distribution was uniform with both modes of ventilation. The alveolar-arterial O2 partial pressure difference during CFV in dogs lying supine was negatively correlated with the reduced ventilation of the dependent lung, which suggests that increased ventilation-perfusion mismatching was responsible for the increase in alveolar-arterial O2 partial pressure difference. The more efficient oxygenation during CFV in dogs lying prone suggests a more efficient matching of ventilation to perfusion, presumably because the distribution of blood flow is also nearly uniform.« less
Under EPA's Environmental Technology Verification Program, Research Triangle Institute (RTI) will operate the Air Pollution Control Technology Center to verify the filtration efficiency and bioaerosol inactivation efficiency of heating, ventilation and air conditioning air cleane...
B-Plant Canyon Ventilation Control System Description
DOE Office of Scientific and Technical Information (OSTI.GOV)
MCDANIEL, K.S.
1999-08-31
Project W-059 installed a new B Plant Canyon Ventilation System. Monitoring and control of the system is implemented by the Canyon Ventilation Control System (CVCS). This document describes the CVCS system components which include a Programmable Logic Controller (PLC) coupled with an Operator Interface Unit (OIU) and application software. This document also includes an Alarm Index specifying the setpoints and technical basis for system analog and digital alarms.
NASA Technical Reports Server (NTRS)
Dinh, Khanh
1994-01-01
Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.
Carlucci, Annalisa; Ceriana, Piero; Mancini, Marco; Cirio, Serena; Pierucci, Paola; D'Artavilla Lupo, Nadia; Gadaleta, Felice; Morrone, Elisa; Fanfulla, Francesco
2015-09-15
Ventilation with continuous positive airway pressure (CPAP) is the gold standard therapy for obstructive sleep apnea (OSA). However, it was recently suggested that a novel mode of ventilation, Bilevel-auto, could be equally effective in treating patients unable to tolerate CPAP. The aim of this study was to investigate the ability of Bilevel-auto to treat OSA patients whose nocturnal ventilatory disturbances are not completely corrected by CPAP. We enrolled 66 consecutive OSA patients, not responsive to (group A) or intolerant of (group B) CPAP treatment, after a full night of manual CPAP titration in a laboratory. Full polysomnography data and daytime sleepiness score were compared for each group in the three different conditions: basal, during CPAP, and during Bilevel-auto. The apnea-hypopnea index decreased significantly during CPAP in both groups; however, in the group A, there was a further significant improvement during Bilevel-auto. The same trend was observed for oxygenation indices, while the distribution and the efficiency of sleep did not differ following the switch from CPAP to Bilevel-auto. This study confirmed the role of Bilevel-auto as an effective therapeutic alternative to CPAP in patients intolerant of this latter mode of ventilation. Moreover, extending the use of Bilevel-auto to those OSA patients not responsive to CPAP, we showed a significantly better correction of nocturnal respiratory disturbances. © 2015 American Academy of Sleep Medicine.
An approach to optimised control of HVAC systems in indoor swimming pools
NASA Astrophysics Data System (ADS)
Ribeiro, Eliseu M. A.; Jorge, Humberto M. M.; Quintela, Divo A. A.
2016-04-01
Indoor swimming pools are recognised as having a high level of energy consumption and present a great potential for energy saving. The energy is spent in several ways such as evaporation heat loss from the pool, high rates of ventilation required to guarantee the indoor air quality, and ambient temperatures with expressive values (typically 28-30°C) required to maintain conditions of comfort. This paper presents an approach to optimising control of heat ventilation and air conditioning systems that could be implemented in a building energy management system. It is easily adapted to any kind of pool and results in significant energy consumption reduction. The development and validation of the control model were carried out with a building thermal simulation software. The use of this control model in the case study building could reduce the energy efficiency index by 7.14 points (7.4% of total) which adds up to an energy cost saving of 15,609€ (7.5% of total).
Carlucci, Annalisa; Ceriana, Piero; Mancini, Marco; Cirio, Serena; Pierucci, Paola; D'Artavilla Lupo, Nadia; Gadaleta, Felice; Morrone, Elisa; Fanfulla, Francesco
2015-01-01
Background: Ventilation with continuous positive airway pressure (CPAP) is the gold standard therapy for obstructive sleep apnea (OSA). However, it was recently suggested that a novel mode of ventilation, Bilevel-auto, could be equally effective in treating patients unable to tolerate CPAP. The aim of this study was to investigate the ability of Bilevel-auto to treat OSA patients whose nocturnal ventilatory disturbances are not completely corrected by CPAP. Methods: We enrolled 66 consecutive OSA patients, not responsive to (group A) or intolerant of (group B) CPAP treatment, after a full night of manual CPAP titration in a laboratory. Full polysomnography data and daytime sleepiness score were compared for each group in the three different conditions: basal, during CPAP, and during Bilevel-auto. Results: The apnea-hypopnea index decreased significantly during CPAP in both groups; however, in the group A, there was a further significant improvement during Bilevel-auto. The same trend was observed for oxygenation indices, while the distribution and the efficiency of sleep did not differ following the switch from CPAP to Bilevel-auto. Conclusions: This study confirmed the role of Bilevel-auto as an effective therapeutic alternative to CPAP in patients intolerant of this latter mode of ventilation. Moreover, extending the use of Bilevel-auto to those OSA patients not responsive to CPAP, we showed a significantly better correction of nocturnal respiratory disturbances. Citation: Carlucci A, Ceriana P, Mancini M, Cirio S, Pierucci P, D'Artavilla Lupo N, Gadaleta F, Morrone E, Fanfulla F. Efficacy of Bilevel-auto treatment in patients with obstructive sleep apnea not responsive to or intolerant of continuous positive airway pressure ventilation. J Clin Sleep Med 2015;11(9):981–985. PMID:25902825
Indoor Air Quality: Is Increased Ventilation the Answer?
ERIC Educational Resources Information Center
Hansen, Shirley
1989-01-01
Explains how indoor air quality is affected by pollutants in the air and also by temperature, humidity, and ventilation. Increased ventilation alone seldom solves the "sick building syndrome." Lists ways to improve indoor air quality and optimize energy efficiency. (MLF)
ENVIRONMENTAL TECHNOLOGY VERIFICATION TEST PROTOCOL, GENERAL VENTILATION FILTERS
The Environmental Technology Verification Test Protocol, General Ventilation Filters provides guidance for verification tests.
Reference is made in the protocol to the ASHRAE 52.2P "Method of Testing General Ventilation Air-cleaning Devices for Removal Efficiency by P...
Zhou, Jing; Han, Yi
2016-01-01
To analyze the ability of pleth variability index (PVI) and respiratory system compliance (RSC) on evaluating the hemodynamic and respiratory effects of positive end expiratory pressure (PEEP), then to direct PEEP settings in mechanically ventilated critical patients. We studied 22 mechanically ventilated critical patients in the intensive care unit. Patients were monitored with classical monitor and a pulse co-oximeter, with pulse sensors attached to patients' index fingers. Hemodynamic data [heart rate (HR), perfusion index (PI), PVI, central venous pressure (CVP), mean arterial pressure (MAP), peripheral blood oxygen saturation (SPO2), peripheral blood oxygen content (SPOC) and peripheral blood hemoglobin (SPHB)] as well as the respiratory data [respiratory rate (RR), tidal volume (VT), RSC and controlled airway pressure] were recorded for 15 min each at 3 different levels of PEEP (0, 5 and 10 cmH2O). Different levels of PEEP (0, 5 and 10 cmH2O) had no obvious effect on RR, HR, MAP, SPO2 and SPOC. However, 10 cmH2O PEEP induced significant hemodynamic disturbances, including decreases of PI, and increases of both PVI and CVP. Meanwhile, 5 cmH2O PEEP induced no significant changes on hemodynamics such as CVP, PI and PVI, but improved the RSC. RSC and PVI may be useful in detecting the hemodynamic and respiratory effects of PEEP, thus may help clinicians individualize PEEP settings in mechanically ventilated patients.
Silva, Cláudia da Costa; Alves, Marta Maria Osório; El Halal, Michel Georges dos Santos; Pinheiro, Sabrina dos Santos; Carvalho, Paulo Roberto Antonacci
2013-01-01
Objective Compare the scores resulting from the Comfort-B scale with the bispectral index in children in an intensive care unit. Methods Eleven children between the ages of 1 month and 16 years requiring mechanical ventilation and sedation were simultaneously classified based on the bispectral index and the Comfort-B scale. Their behavior was recorded using digital photography, and the record was later evaluated by three independent evaluators. Agreement tests (Bland-Altman and Kappa) were then performed. The correlation between the two methods (Pearson correlation) was tested. Results In total, 35 observations were performed on 11 patients. Based on the Kappa coefficient, the agreement among evaluators ranged from 0.56 to 0.75 (p<0.001). There was a positive and consistent association between the bispectral index and the Comfort-B scale [r=0.424 (p=0.011) to r=0.498 (p=0.002)]. Conclusion Due to the strong correlation between the independent evaluators and the consistent correlation between the two methods, the results suggest that the Comfort-B scale is reproducible and useful in classifying the level of sedation in children requiring mechanical ventilation. PMID:24553512
[Lung protective ventilation - pathophysiology and diagnostics].
Uhlig, Stefan; Frerichs, Inéz
2008-06-01
Mechanical ventilation may lead to lung injury depending on the ventilatory settings (e.g. pressure amplitudes, endexpiratory pressures, frequency) and the length of mechanical ventilation. Particularly in the inhomogeneously injured lungs of ARDS patients, alveolar overextension results in volutrauma, cyclic opening and closure of alveolar units in atelectrauma. Particularly important appears to be the fact that these processes may also cause biotrauma, i.e. the ventilator-induced hyperactivation of inflammatory responses in the lung. These side effects are reduced, but not eliminated with the currently recommended ventilation strategy with a tidal volume of 6 ml/kg idealized body weight. It is our hope that in the future optimization of ventilator settings will be facilated by bedside monitoring of novel indices of respiratory mechanics such as the stress index or the Slice technique, and by innovative real-time imaging technologies such as electrical impedance tomography.
Association Between Enteral Feeding, Weight Status, and Mortality in a Medical Intensive Care Unit.
Vest, Michael T; Kolm, Paul; Bowen, James; Trabulsi, Jillian; Lennon, Shannon L; Shapero, Mary; McGraw, Patty; Halbert, James; Jurkovitz, Claudine
2018-03-01
Clinical practice guidelines recommend enteral nutrition for most patients receiving mechanical ventilation. However, recently published evidence on the effect of enteral nutrition on mortality, particularly for patients who are well nourished, is conflicting. To examine the association between enteral feeding and hospital mortality in critically ill patients receiving mechanical ventilation and to determine if body mass index mediates this relationship. A retrospective cohort study of patients receiving mechanical ventilation admitted to a medical intensive care unit in 2013. Demographic and clinical variables were collected. Cox proportional hazards regression was used to examine the relationship between an enteral feeding order and hospital mortality and to determine if the relationship was mediated by body mass index. Of 777 patients who had 811 hospitalizations requiring mechanical ventilation, 182 (23.4%) died in the hospital. A total of 478 patients (61.5%) received an order for enteral tube feeding, which was associated with a lower risk of death (hazard ratio, 0.41; 95% CI, 0.29-0.59). Body mass index did not mediate the relationship between mortality and receipt of an order for enteral feeding. Median stay in the unit was 3.6 days. Most deaths (72.0%) occurred more than 48 hours after admission. The finding of a positive association between an order for enteral feeding and survival supports enteral feeding of patients in medical intensive care units. Furthermore, the beneficial effect of enteral feeding appears to apply to patients regardless of body mass index. ©2018 American Association of Critical-Care Nurses.
Contextualizing ethics: ventilators, H1N1 and marginalized populations.
Silva, Diego S; Nie, Jason X; Rossiter, Kate; Sahni, Sachin; Upshur, Ross E G
2010-01-01
If the H1N1 pandemic worsens, there may not be enough ventilated beds to care for all persons with respiratory failure. To date, researchers who explicitly discuss the ethics of intensive care unit admission and the allocation of ventilators during an influenza pandemic have based criteria predominantly on the principles of utility and efficiency, that is, promoting actions that maximize the greatest good for the greatest number of people. However, haphazardly applying utility and efficiency potentially disadvantages marginalized populations who might be at increased risk of severe reactions to H1N1. In Canada, Aboriginals represent 3% of Canadians, yet 11% of H1N1 cases requiring hospitalization involve Aboriginal persons. Aboriginal persons suffer from high rates of obesity due to socio-economic inequalities. Obesity is also a risk factor for severe H1N1 reactions. Yet, since obesity is found to increase the duration of stay in ventilated beds and a long stay is not considered an optimal use of ventilators, applying the principles of utility and efficiency may magnify existing social inequalities. Although promoting utility and efficiency is important, other ethical principles, such as equity and need, require thoughtful consideration and implementation. Furthermore, since public resources are being used to address a public health hazard, the viewpoints of the public, and specifically stakeholders who will be disproportionately affected, should inform decision-makers. Finally, giving attention to the needs and rights of marginalized populations means that ventilators should not be allocated based on criteria that exacerbate the social injustices faced by these groups of people.
Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France.
Canha, N; Mandin, C; Ramalho, O; Wyart, G; Ribéron, J; Dassonville, C; Hänninen, O; Almeida, S M; Derbez, M
2016-06-01
The aim of this study was to characterize the relationship between Indoor Air Quality (IAQ) and ventilation in French classrooms. Various parameters were measured over one school week, including volatile organic compounds, aldehydes, particulate matter (PM2.5 mass concentration and number concentration), carbon dioxide (CO2 ), air temperature, and relative humidity in 51 classrooms at 17 schools. The ventilation was characterized by several indicators, such as the air exchange rate, ventilation rate (VR), and air stuffiness index (ICONE), that are linked to indoor CO2 concentration. The influences of the season (heating or non-heating), type of school (nursery or elementary), and ventilation on the IAQ were studied. Based on the minimum value of 4.2 l/s per person required by the French legislation for mechanically ventilated classrooms, 91% of the classrooms had insufficient ventilation. The VR was significantly higher in mechanically ventilated classrooms compared with naturally ventilated rooms. The correlations between IAQ and ventilation vary according to the location of the primary source of each pollutant (outdoor vs. indoor), and for an indoor source, whether it is associated with occupant activity or continuous emission. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Maa, Suh-Hwa; Wang, Chiu-Hua; Hsu, Kuang-Hung; Lin, Horng-Chyuan; Yee, Brian; MacDonald, Karen
2013-01-01
Background. Acupressure has been shown to improve respiratory parameters. We investigated the effects of acupressure on weaning indices in stable coma patients receiving mechanical ventilation. Methods. Patients were randomly allocated to one of three treatments: standard care with adjunctive acupressure on one (n = 32) or two days (n = 31) and standard care (n = 31). Acupressure in the form of 10 minutes of bilateral stimulation at five acupoints was administered per treatment session. Weaning indices were collected on two days before, right after, and at 0.5 hrs, 1 hr, 1.5 hrs, 2 hrs, 2.5 hrs, 3 hrs, 3.5 hrs, and 4 hrs after the start of treatment. Results. There were statistically significant improvements in tidal volumes and index of rapid shallow breathing in the one-day and two-day adjunctive acupressure study arms compared to the standard care arm immediately after acupressure and persisting until 0.5, 1 hr, and 2 hrs after adjustment for covariates. Conclusions. In the stable ventilated coma patient, adjunctive acupressure contributes to improvements in tidal volumes and the index of rapid shallow breathing, the two indices most critical for weaning patients from mechanical ventilation. These effects tend to be immediate and likely to be sustained for 1 to 2 hours. PMID:23710234
Particle transport in low-energy ventilation systems. Part 1: theory of steady states.
Bolster, D T; Linden, P F
2009-04-01
Many modern low-energy ventilation schemes, such as displacement or natural ventilation, take advantage of temperature stratification in a space, extracting the warmest air from the top of the room. The adoption of these energy-efficient ventilation systems still requires the provision of acceptable indoor air quality. In this work we study the steady state transport of particulate contaminants in a displacement-ventilated space. Representing heat sources as ideal sources of buoyancy, analytical models are developed that allow us to compare the average efficiency of contaminant removal between traditional and modern low-energy systems. We found that on average traditional and low-energy systems are similar in overall pollutant removal efficiency, although quite different vertical distributions of contaminant can exist, thus affecting individual exposure. While the main focus of this work is on particles where the dominant mode of deposition is by gravitational settling, we also discuss additional deposition mechanisms and show that the qualitative observations we make carry over to cases where such mechanisms must be included. We illustrate that while average concentration of particles for traditional mixing systems and low energy displacement systems are similar, local concentrations can vary significantly with displacement systems. Depending on the source of the particles this can be better or worse in terms of occupant exposure and engineers should take due diligence accordingly when designing ventilation systems.
Wang, W-F; Liu, S; Xu, B
2017-03-01
To investigate the protective effects and mechanism of ketamine on acute lung injury induced by mechanical ventilation. 63 patients with acute lung injury caused by mechanical ventilation in our hospital between June 2014 and May 2015 were chosen and divided into three groups: group A, B, and C. Group A (20 cases) received conventional treatment. Group B (21 cases) was treated with propofol and group C (22 cases) with ketamine. The ventilator application time, the success rate of weaning, the mortality rate, inflammation index (IL-1, Caspase-1, and NF-κB), pulmonary function index and oxygen saturation were compared. The ventilator application time and the mortality rate of group B and group C were significantly (p < 0.05) lower than those of group A. The success rate of weaning of groups B and C was higher (p < 0.05) than that of group A. There was no difference between groups B and C. After intervention, the levels of PaO2 and SpO2 in the three groups increased, while the level of PaCO2decreased with better improvement in group B and group C than in group A (p < 0.05), groups B and C being similar (p > 0.05). After the intervention, the levels of FEV1, FEV1/FVC, FVC and PEER in the three groups increased, but more remarkably in group B and group C (p < 0.05), in which there was no difference. After the intervention, the levels of IL-1β, Caspase-1, and NF-κB in the three groups decreased with the levels of group C obviously lower (p < 0.05) than those of groups B and A, the highest. Both ketamine and propofol can improve the blood gas and pulmonary function index of patients with acute lung injury caused by mechanical ventilation. They shorten the application time of ventilator, improve the success rate of weaning and reduce the mortality rate which is probably related to the reduction of the degree of inflammatory reaction. Ketamine is more effective in reducing inflammatory factors including IL-1β, Caspase-1, and NF-κB than propofol.
Multifaceted bench comparative evaluation of latest intensive care unit ventilators.
Garnier, M; Quesnel, C; Fulgencio, J-P; Degrain, M; Carteaux, G; Bonnet, F; Similowski, T; Demoule, A
2015-07-01
Independent bench studies using specific ventilation scenarios allow testing of the performance of ventilators in conditions similar to clinical settings. The aims of this study were to determine the accuracy of the latest generation ventilators to deliver chosen parameters in various typical conditions and to provide clinicians with a comprehensive report on their performance. Thirteen modern intensive care unit ventilators were evaluated on the ASL5000 test lung with and without leakage for: (i) accuracy to deliver exact tidal volume (VT) and PEEP in assist-control ventilation (ACV); (ii) performance of trigger and pressurization in pressure support ventilation (PSV); and (iii) quality of non-invasive ventilation algorithms. In ACV, only six ventilators delivered an accurate VT and nine an accurate PEEP. Eleven devices failed to compensate VT and four the PEEP in leakage conditions. Inspiratory delays differed significantly among ventilators in invasive PSV (range 75-149 ms, P=0.03) and non-invasive PSV (range 78-165 ms, P<0.001). The percentage of the ideal curve (concomitantly evaluating the pressurization speed and the levels of pressure reached) also differed significantly (range 57-86% for invasive PSV, P=0.04; and 60-90% for non-invasive PSV, P<0.001). Non-invasive ventilation algorithms efficiently prevented the decrease in pressurization capacities and PEEP levels induced by leaks in, respectively, 10 and 12 out of the 13 ventilators. We observed real heterogeneity of performance amongst the latest generation of intensive care unit ventilators. Although non-invasive ventilation algorithms appear to maintain adequate pressurization efficiently in the case of leakage, basic functions, such as delivered VT in ACV and pressurization in PSV, are often less reliable than the values displayed by the device suggest. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Longhini, Federico; Colombo, Davide; Pisani, Lara; Idone, Francesco; Chun, Pan; Doorduin, Jonne; Ling, Liu; Alemani, Moreno; Bruni, Andrea; Zhaochen, Jin; Tao, Yu; Lu, Weihua; Garofalo, Eugenio; Carenzo, Luca; Maggiore, Salvatore Maurizio; Qiu, Haibo; Heunks, Leo; Antonelli, Massimo; Nava, Stefano; Navalesi, Paolo
2017-10-01
The objective of this study was to assess ability to identify asynchronies during noninvasive ventilation (NIV) through ventilator waveforms according to experience and interface, and to ascertain the influence of breathing pattern and respiratory drive on sensitivity and prevalence of asynchronies. 35 expert and 35 nonexpert physicians evaluated 40 5-min NIV reports displaying flow-time and airway pressure-time tracings; identified asynchronies were compared with those ascertained by three examiners who evaluated the same reports displaying, additionally, tracings of diaphragm electrical activity. We determined: 1) sensitivity, specificity, and positive and negative predictive values; 2) the correlation between the double true index (DTI) of each report ( i.e., the ratio between the sum of true positives and true negatives, and the overall breath count) and the corresponding asynchrony index (AI); and 3) the influence of breathing pattern and respiratory drive on both AI and sensitivity. Sensitivities to detect asynchronies were low either according to experience (0.20 (95% CI 0.14-0.29) for expert versus 0.21 (95% CI 0.12-0.30) for nonexpert, p=0.837) or interface (0.28 (95% CI 0.17-0.37) for mask versus 0.10 (95% CI 0.05-0.16) for helmet, p<0.0001). DTI inversely correlated with the AI (r 2 =0.67, p<0.0001). Breathing pattern and respiratory drive did not affect prevalence of asynchronies and sensitivity. Patient-ventilator asynchrony during NIV is difficult to recognise solely by visual inspection of ventilator waveforms.
NASA Astrophysics Data System (ADS)
Kong, Lingwei; Wang, Lu; Zhang, Yi; Mei, Rongwu; Zhang, Yu
2018-06-01
In this study, a new coupling system of biological filter bed and subsurface-flow constructed wetland based on the self-ventilation network was proposed, and the comparative pollutant removal efficiency at low and high influent concentration of the pilot coupling system with different substrates configurations were investigated. The study found that: The comparison system (b) had better removal rates than that of the original system (a), and the removal rate when treating low influent concentration was 74.10%, 94.14%, 73.57% and 69.53%, while in high influent concentration case was 81.30%, 90.28%, 88.57% and 75.36% for CODCr , NH4+ -N, TN and TP, respectively. The removal of the above main water indexes of the comparison system (b) promoted by 11.00%, 11.55%, 2.69% and 8.09% respectively in low influent concentration case and 4.20%, 9.20%, 7.66% and 13.61% respectively in high influent concentration case when comparing to the original system (a), which showed that the optimized configuration of various kinds of substrates was significant and was more beneficial to the degradation and removal of pollutants. The adsorption and interception function of substrates in the constructed wetland was the main way of phosphorus removal. The function of self-ventilation ensured the amount of DO in the coupling system, making the phosphorus removal was less affected comparing to structure of traditional wetland.
Short-term airing by natural ventilation - modeling and control strategies.
Perino, M; Heiselberg, P
2009-10-01
The need to improve the energy efficiency of buildings requires new and more efficient ventilation systems. It has been demonstrated that innovative operating concepts that make use of natural ventilation seem to be more appreciated by occupants. This kind of system frequently integrates traditional mechanical ventilation components with natural ventilation devices, such as motorized windows and louvers. Among the various ventilation strategies that are currently available, buoyancy driven single-sided natural ventilation has proved to be very effective and can provide high air change rates for temperature and IAQ control. However, in order to promote a wider applications of these systems, an improvement in the knowledge of their working principles and the availability of new design and simulation tools is necessary. In this context, the paper analyses and presents the results of a research that was aimed at developing and validating numerical models for the analysis of buoyancy driven single-sided natural ventilation systems. Once validated, these models can be used to optimize control strategies in order to achieve satisfactory indoor comfort conditions and IAQ. Practical Implications Numerical and experimental analyses have proved that short-term airing by intermittent ventilation is an effective measure to satisfactorily control IAQ. Different control strategies have been investigated to optimize the capabilities of the systems. The proposed zonal model has provided good performances and could be adopted as a design tool, while CFD simulations can be profitably used for detailed studies of the pollutant concentration distribution in a room and to address local discomfort problems.
Nay, M-A; Auvet, A; Mankikian, J; Herve, V; Dequin, P-F; Guillon, A
2017-06-01
Bronchoscopy during mechanical ventilation of patients' lungs significantly affects ventilation because of partial obstruction of the tracheal tube, and may thus be omitted in the most severely ill patients. It has not previously been possible to reduce the external diameter of the bronchoscope without reducing the diameter of the suction channel, thus reducing the suctioning capacity of the device. We believed that a better-designed bronchoscope could improve the safety of bronchoscopy in patients whose lungs were ventilated. We designed a flexible bronchoscope prototype with a drumstick-shaped head consisting of a long, thin proximal portion; a short and large distal portion for camera docking; and a large suction channel throughout the length of the device. The aims of our study were to test the impact of our prototype on mechanical ventilation when inserted into the tracheal tube, and to assess suctioning capacity. We first tested the efficiency of the suction channel, and demonstrated that the suction flow of the prototype was similar to that of conventional adult bronchoscopes. We next evaluated the consequences of bronchoscopy when using the prototype on minute ventilation and intrathoracic pressures during mechanical ventilation: firstly, in vitro using a breathing simulator; and secondly, in vivo using a porcine model of pulmonary ventilation. The insertion of adult bronchoscopes into the tracheal tube immediately impaired the protective ventilation strategy employed, whereas the prototype preserved it. For the first time, we have developed an innovative flexible bronchoscope designed for bronchoscopy during invasive mechanical ventilation, that both preserved the protective ventilation strategy, and enabled efficient suction flow. © 2017 The Association of Anaesthetists of Great Britain and Ireland.
Bio-Defense Now: 56 Suggestions for Immediate Improvements
2005-05-01
Air Education and Training Command HVAC Heating, Ventilation and Air Conditioning ICAM Improved Chemical Agent Monitor ICD-9-CM Internal...conditioning ( HVAC ) system capabilities, making a big difference in removal of many BW agents. High Efficiency Particulate Air (HEPA) filters are also...agents. This program has developed biological sensor-activated heating, ventilation, and air conditioning ( HVAC ) control sys- tems, high efficiency
Radon safety in terms of energy efficiency classification of buildings
NASA Astrophysics Data System (ADS)
Vasilyev, A.; Yarmoshenko, I.; Zhukovsky, M.
2017-06-01
According to the results of survey in Ekaterinburg, Russia, indoor radon concentrations above city average level have been found in each of the studied buildings with high energy efficiency class. Measures to increase energy efficiency were confirmed to decrease the air exchange rate and accumulation of high radon concentrations indoors. Despite of recommendations to use mechanical ventilation with heat recovery as the main scenario for reducing elevated radon concentrations in energy-efficient buildings, the use of such systems did not show an obvious advantage. In real situation, mechanical ventilation system is not used properly both in the automatic and manual mode, which does not give an obvious advantage over natural ventilation in the climate of the Middle Urals in Ekaterinburg. Significant number of buildings with a high class of energy efficiency and built using modern space-planning decisions contributes to an increase in the average radon concentration. Such situation contradicts to “as low as reasonable achievable” principle of the radiation protection.
NanoClusters Enhance Drug Delivery in Mechanical Ventilation
NASA Astrophysics Data System (ADS)
Pornputtapitak, Warangkana
The overall goal of this thesis was to develop a dry powder delivery system for patients on mechanical ventilation. The studies were divided into two parts: the formulation development and the device design. The pulmonary system is an attractive route for drug delivery since the lungs have a large accessible surface area for treatment or drug absorption. For ventilated patients, inhaled drugs have to successfully navigate ventilator tubing and an endotracheal tube. Agglomerates of drug nanoparticles (also known as 'NanoClusters') are fine dry powder aerosols that were hypothesized to enable drug delivery through ventilator circuits. This Thesis systematically investigated formulations of NanoClusters and their aerosol performance in a conventional inhaler and a device designed for use during mechanical ventilation. These engineered powders of budesonide (NC-Bud) were delivered via a MonodoseRTM inhaler or a novel device through commercial endotracheal tubes, and analyzed by cascade impaction. NC-Bud had a higher efficiency of aerosol delivery compared to micronized stock budesonide. The delivery efficiency was independent of ventilator parameters such as inspiration patterns, inspiration volumes, and inspiration flow rates. A novel device designed to fit directly to the ventilator and endotracheal tubing connections and the MonodoseRTM inhaler showed the same efficiency of drug delivery. The new device combined with NanoCluster formulation technology, therefore, allowed convenient and efficient drug delivery through endotracheal tubes. Furthermore, itraconazole (ITZ), a triazole antifungal agent, was formulated as a NanoCluster powder via milling (top-down process) or precipitation (bottom-up process) without using any excipients. ITZ NanoClusters prepared by wet milling showed better aerosol performance compared to micronized stock ITZ and ITZ NanoClusters prepared by precipitation. ITZ NanoClusters prepared by precipitation methods also showed an amorphous state while milled ITZ NanoClusters maintained the crystalline character. Overall, NanoClusters prepared by various processes represent a potential engineered drug particle approach for inhalation therapy since they provide effective aerosol properties and stability due to the crystalline state of the drug powders. Future work will continue to explore formulation and delivery performance in vitro and in vivo..
The Air Pollution Control Technology Verification Center has selected general ventilation air cleaners as a technology area. The Generic Verification Protocol for Biological and Aerosol Testing of General Ventilation Air Cleaners is on the Environmental Technology Verification we...
Health and Wellbeing of Occupants in Highly Energy Efficient Buildings: A Field Study.
Wallner, Peter; Tappler, Peter; Munoz, Ute; Damberger, Bernhard; Wanka, Anna; Kundi, Michael; Hutter, Hans-Peter
2017-03-19
Passive houses and other highly energy-efficient buildings need mechanical ventilation. However, ventilation systems in such houses are regarded with a certain degree of skepticism by parts of the public due to alleged negative health effects. Within a quasi-experimental field study, we investigated if occupants of two types of buildings (mechanical vs. natural ventilation) experience different health, wellbeing and housing satisfaction outcomes and if associations with indoor air quality exist. We investigated 123 modern homes (test group: with mechanical ventilation; control group: naturally ventilated) built in the years 2010 to 2012 in the same geographic area and price range. Interviews of occupants based on standardized questionnaires and measurements of indoor air quality parameters were conducted twice (three months after moving in and one year later). In total, 575 interviews were performed (respondents' mean age 37.9 ± 9 years in the test group, 37.7 ± 9 years in the control group). Occupants of the test group rated their overall health status and that of their children not significantly higher than occupants of the control group at both time points. Adult occupants of the test group reported dry eyes statistically significantly more frequently compared to the control group (19.4% vs. 12.5%). Inhabitants of energy-efficient, mechanically ventilated homes rated the quality of indoor air and climate significantly higher. Self-reported health improved more frequently in the mechanically ventilated new homes ( p = 0.005). Almost no other significant differences between housing types and measuring time points were observed concerning health and wellbeing or housing satisfaction. Associations between vegetative symptoms (dizziness, nausea, headaches) and formaldehyde concentrations as well as between CO₂ levels and perceived stale air were observed. However, both associations were independent of the type of ventilation. In summary, occupants of the mechanically ventilated homes rated their health status slightly higher and their health improved significantly more frequently than in occupants of the control group. As humidity in homes with mechanical ventilation was lower, it seems plausible that the inhabitants reported dry eyes more frequently.
Blancas, R; Martínez-González, Ó; Ballesteros, D; Núñez, A; Luján, J; Rodríguez-Serrano, D; Hernández, A; Martínez-Díaz, C; Parra, C M; Matamala, B L; Alonso, M A; Chana, M
2018-02-07
To assess the correlation between left ventricular outflow tract velocity time integral (LVOT VTI) and stroke volume index (SVI) calculated by thermodilution methods in ventilated critically ill patients. A prospective, descriptive, multicenter study was performed. Five intensive care units from university hospitals. Patients older than 17 years needing mechanical ventilation and invasive hemodynamic monitoring were included. LVOT VTI was measured by pulsatile Doppler echocardiography. Calculations of SVI were performed through a floating pulmonary artery catheter (PAC) or a Pulse index Contour Cardiac Output (PiCCO ® ) thermodilution methods. The relation between LVOT VTI and SVI was tested by linear regression analysis. One hundred and fifty-six paired measurements were compared. Mean LVOT VTI was 20.83±4.86cm and mean SVI was 41.55±9.55mL/m 2 . Pearson correlation index for these variables was r=0.644, p<0.001; ICC was 0.52 (CI 95% 0.4-0.63). When maximum LVOT VTI was correlated with SVI, Pearson correlation index was r=0.62, p<0.001. Correlation worsened for extreme values, especially for those with higher LVOT VTI. LVOT VTI could be a complementary hemodynamic evaluation in selected patients, but does not eliminate the need for invasive monitoring at the present time. The weak correlation between LVOT VTI and invasive monitoring deserves additional assessment to identify the factors affecting this disagreement. Copyright © 2018 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.
Prone versus supine position in mechanically ventilated children: a pilot study.
Sawhney, Ashu; Kumar, Nirmal; Sreenivas, Vishnubhatla; Gupta, Sangeeta; Tyagi, Vineet; Puliyel, Jacob M
2005-05-01
It is known that mechanically ventilated patients in the prone position have improved oxygenation compared with those supine. We did a prospective, randomized, controlled trial to evaluate the effect of prone position during mechanical ventilation, on survival in critically ill children. Forty-two children needing mechanical ventilation for various illnesses were randomized to receive initial ventilation for four hours prone or supine by drawing lots. Initial severity of illness and blood gases in all children were noted. In a crossover design, after the initial four hours the children were turned over and ventilated in the alternate posture for an hour. Oxygenation parameters and mean airway pressures were noted at one hour, four hours, and five hours. Mortality, duration of ventilation, and the above parameters were compared in the two groups. Initial PRISM scores were similar in the two groups. Mortality in the prone group was less than in the supine group. The odds ratio of mortality was 0.20 (95% CI 0.05-0.75). Duration of ventilation was similar in the two groups. The oxygenation index was significantly lower in the prone group at one, four, and five hours after onset of ventilation. Prone position in the first few hours of ventilation significantly improves gas exchange and oxygenation, reduces the mean airway pressures required to ventilate children, and may cause significant improvement in survival. Our study protocol allowed ventilator settings to be changed as needed during ventilation.
A new method for noninvasive measurement of pulmonary gas exchange using expired gas.
West, John B; Prisk, G Kim
2018-01-01
Measurement of the gas exchange efficiency of the lung is often required in the practice of pulmonary medicine and in other settings. The traditional standard is the values of the PO2, PCO2, and pH of arterial blood. However arterial puncture requires technical expertise, is invasive, uncomfortable for the patient, and expensive. Here we describe how the composition of expired gas can be used in conjunction with pulse oximetry to obtain useful measures of gas exchange efficiency. The new procedure is noninvasive, well tolerated by the patient, and takes only a few minutes. It could be particularly useful when repeated measurements of pulmonary gas exchange are required. One product of the procedure is the difference between the PO2 of end-tidal alveolar gas and the calculated PO2 of arterial blood. This measurement is related to the classical alveolar-arterial PO2 difference based on ideal alveolar gas. However that traditional index is heavily influenced by lung units with low ventilation-perfusion ratios, whereas the new index has a broader physiological basis because it includes contributions from the whole lung. Copyright © 2017 Elsevier B.V. All rights reserved.
The transmission characteristics of indoor particles under different ventilation conditions
NASA Astrophysics Data System (ADS)
Lv, Yang; Wang, Haifeng; Wei, Shanshan
2017-11-01
In modern society, ventilation is an important method for removing indoor particles. This study applies the parameter of attenuation index to analyze the effect of the removal of indoor particles in the two typical ventilation strategies called ceiling exhaust and slit exhaust strategy. Experiment was conducted in a chamber and riboflavin particles were used as the indoor particles source, instantaneous microbial detection (IMD) used to measure the particulate concentration. Conclusions can be found that air exchange rate is an important factor affecting the indoor particle concentration distribution. In the process of indoor free settling(air exchange rate is 0 h-1), the deposition rate were 0.086 h-1, 0.122 h-1, 0.173 h-1 for the particles of 0.5-1.0 μm, 1.0-3.0μm and 3.0-5.0 μm. When the air exchange rate increased to 2.5 h-1, the differences in the attenuation index is significant. There was also a significant linear relationship between air exchange rate and attenuation index. Furthermore, the effect of the slit exhaust strategy on the removal of coarse particles is more remarkable as the increasing air exchange rate.
Singla, Abhishek; Turner, Paul; Pendurthi, Madhu Kalyan; Agrawal, Vrinda; Modrykamien, Ariel
2014-02-01
The acute respiratory distress syndrome (ARDS) is a life-threatening condition, whereas the presence of diabetes has been shown to be protective in its development. We undertook this study to assess the association of type II diabetes mellitus with clinical outcomes in patients with ARDS. We retrospectively examined the medical records of consecutive series of patients with ARDS requiring mechanical ventilation from January 2008 to March 2011. Patients with type I diabetes were excluded from the study. Clinical outcomes such as ventilator-free days, mortality, length of stay in the hospital and intensive care unit (ICU), and reintubations were compared based on the presence of diabetes. Multivariate regression model was used to find if the presence of type II diabetes mellitus predicts ventilator-free days at day 28. Two hundred forty-nine patients with ARDS were admitted to the ICU during the study period. Fifty (20%) subjects had type II diabetes mellitus. Differences in ventilator-free days, in-hospital mortality, reintubation rate, and length of stay in the hospital or ICU were not statistically significant between diabetic and nondiabetic patients with ARDS. Acute Physiologic and Chronic Health Evaluation II, ICU specialty, use of vasopressors, and the need for reintubation were predictors of ventilator-free days at day 28. The presence of type II diabetes mellitus and its adjustment by body mass index did not show association with ventilator-free days at day 28. The presence of type II diabetes mellitus is not associated with clinical outcomes in ARDS, even when its presence is adjusted by body mass index. © 2013.
Flow analysis of airborne particles in a hospital operating room
NASA Astrophysics Data System (ADS)
Faeghi, Shiva; Lennerts, Kunibert
2016-06-01
Preventing airborne infections during a surgery has been always an important issue to deliver effective and high quality medical care to the patient. One of the important sources of infection is particles that are distributed through airborne routes. Factors influencing infection rates caused by airborne particles, among others, are efficient ventilation and the arrangement of surgical facilities inside the operating room. The paper studies the ventilation airflow pattern in an operating room in a hospital located in Tehran, Iran, and seeks to find the efficient configurations with respect to the ventilation system and layout of facilities. This study uses computational fluid dynamics (CFD) and investigates the effects of different inflow velocities for inlets, two pressurization scenarios (equal and excess pressure) and two arrangements of surgical facilities in room while the door is completely open. The results show that system does not perform adequately when the door is open in the operating room under the current conditions, and excess pressure adjustments should be employed to achieve efficient results. The findings of this research can be discussed in the context of design and controlling of the ventilation facilities of operating rooms.
Shi, Yan; Zhang, Bolun; Cai, Maolin; Zhang, Xiaohua Douglas
2017-09-01
Mechanical ventilation is a key therapy for patients who cannot breathe adequately by themselves, and dynamics of mechanical ventilation system is of great significance for life support of patients. Recently, models of mechanical ventilated respiratory system with 1 lung are used to simulate the respiratory system of patients. However, humans have 2 lungs. When the respiratory characteristics of 2 lungs are different, a single-lung model cannot reflect real respiratory system. In this paper, to illustrate dynamic characteristics of mechanical ventilated respiratory system with 2 different lungs, we propose a mathematical model of mechanical ventilated respiratory system with 2 different lungs and conduct experiments to verify the model. Furthermore, we study the dynamics of mechanical ventilated respiratory system with 2 different lungs. This research study can be used for improving the efficiency and safety of volume-controlled mechanical ventilation system. Copyright © 2016 John Wiley & Sons, Ltd.
Krajewski, Wojciech; Kucharska, Malgorzata; Wesolowski, Wiktor; Stetkiewicz, Jan; Wronska-Nofer, Teresa
2007-03-01
The aim of this study was to assess the level of occupational exposure to nitrous oxide (N(2)O) in operating rooms (ORs), as related to different ventilation and scavenging systems used to remove waste anaesthetic gases from the work environment. The monitoring of N(2)O in the air covered 35 ORs in 10 hospitals equipped with different systems for ventilation and anaesthetic scavenging. The examined systems included: natural ventilation with supplementary fresh air provided by a pressure ventilation system (up to 6 air changes/h); pressure and exhaust ventilation systems equipped with ventilation units supplying fresh air to and discharging contaminated air outside the working area (more than 10 air changes/h); complete air-conditioning system with laminar air flow (more than 15 air changes/h). The measurements were carried out during surgical procedures (general anaesthesia induced intravenously and maintained with inhaled N(2)O and sevofluran delivered through cuffed endotracheal tubes) with connected or disconnected air scavenging. Air was collected from the breathing zone of operating personnel continuously through the whole time of anaesthesia to Tedlar((R)) bags, and N(2)O concentrations in air samples were analyzed by adsorption gas chromatography/mass spectrometry. N(2)O levels in excess of the occupational exposure limit (OEL) value of 180mg/m(3) were registered in all ORs equipped with ventilation systems alone. The OEL value was exceeded several times in rooms with natural ventilation plus supplementary pressure ventilations and twice or less in those with pressure/exhaust ventilation systems or air conditioning. N(2)O levels below or within the OEL value were observed in rooms where the system of air conditioning or pressure/exhaust ventilation was combined with scavenging systems. Systems combining natural/pressure ventilation with scavenging were inadequate to maintain N(2)O concentration below the OEL value. Air conditioning and an efficient pressure/exhaust ventilation (above 12 air exchanges/h) together with efficient active scavenging systems are sufficient to sustain N(2)O exposure in ORs at levels below or within the OEL value of 180mg/m(3).
Local ventilation solution for large, warm emission sources.
Kulmala, Ilpo; Hynynen, Pasi; Welling, Irma; Säämänen, Arto
2007-01-01
In a foundry casting line, contaminants are released from a large area. Casting fumes include both volatile and particulate compounds. The volatile fraction contains hydrocarbons, whereas the particulate fraction mostly comprises a mixture of vaporized metal fumes. Casting fumes lower the air quality in foundries. The design of local ventilation for the casting area is a challenging task, because of the large casting area and convection plumes from warm moulds. A local ventilation solution for the mould casting area was designed and dimensioned with the aid of computational fluid dynamic (CFD) calculations. According to the calculations, the most efficient solution was a push-pull ventilation system. The prototype of the push-pull system was built and tested in actual operation at the foundry. The push flow was generated by a free plane jet that blew across the 10 m wide casting area towards an exhaust hood on the opposite side of the casting lines. The capture efficiency of the prototype was determined by the tracer gas method. The measured capture efficiencies with push jet varied between 40 and 80%, depending on the distance between the source and the exhaust. With the aid of the push flow, the average capture efficiency was increased from 40 (without jet) to 60%.
This project evaluated the effectiveness, first costs and operational costs of various types of residential ventilation systems in three different climates in the U.S. The Agency, through its Energy Star Program, recommends that builders construct homes that are energy efficient ...
NASA Technical Reports Server (NTRS)
Saltzman, E. J.
1983-01-01
Better aerodynamics and ventilation increases fuel efficiency and decreases shipping losses. Trailer is ventilated and cooled by inlet ports in front of rig and outlet ports in middle and rear. Rounded cab and fairing reduce drag by creating an attached airflow.
Marshall, Helen; Horsley, Alex; Taylor, Chris J; Smith, Laurie; Hughes, David; Horn, Felix C; Swift, Andrew J; Parra-Robles, Juan; Hughes, Paul J; Norquay, Graham; Stewart, Neil J; Collier, Guilhem J; Teare, Dawn; Cunningham, Steve; Aldag, Ina; Wild, Jim M
2017-08-01
Hyperpolarised 3 He ventilation-MRI, anatomical lung MRI, lung clearance index (LCI), low-dose CT and spirometry were performed on 19 children (6-16 years) with clinically stable mild cystic fibrosis (CF) (FEV 1 >-1.96), and 10 controls. All controls had normal spirometry, MRI and LCI. Ventilation-MRI was the most sensitive method of detecting abnormalities, present in 89% of patients with CF, compared with CT abnormalities in 68%, LCI 47% and conventional MRI 22%. Ventilation defects were present in the absence of CT abnormalities and in patients with normal physiology, including LCI. Ventilation-MRI is thus feasible in young children, highly sensitive and provides additional information about lung structure-function relationships. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Fifty Years of Research in ARDS. Respiratory Mechanics in Acute Respiratory Distress Syndrome.
Henderson, William R; Chen, Lu; Amato, Marcelo B P; Brochard, Laurent J
2017-10-01
Acute respiratory distress syndrome is a multifactorial lung injury that continues to be associated with high levels of morbidity and mortality. Mechanical ventilation, although lifesaving, is associated with new iatrogenic injury. Current best practice involves the use of small Vt, low plateau and driving pressures, and high levels of positive end-expiratory pressure. Collectively, these interventions are termed "lung-protective ventilation." Recent investigations suggest that individualized measurements of pulmonary mechanical variables rather than population-based ventilation prescriptions may be used to set the ventilator with the potential to improve outcomes beyond those achieved with standard lung protective ventilation. This review outlines the measurement and application of clinically applicable pulmonary mechanical concepts, such as plateau pressures, driving pressure, transpulmonary pressures, stress index, and measurement of strain. In addition, the concept of the "baby lung" and the utility of dynamic in addition to static measures of pulmonary mechanical variables are discussed.
Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days.
Thomachot, Laurent; Leone, Marc; Razzouk, Karim; Antonini, François; Vialet, Renaud; Martin, Claude
2002-01-01
To determine whether extended use (7 days) would affect the efficiency on heat and water preservation of a hydrophobic condenser humidifier as well as the rate of ventilation-acquired pneumonia, compared with 1 day of use. Prospective, controlled, randomized, not blinded, clinical study. Twelve-bed intensive care unit of a university hospital. One hundred and fifty-five consecutive patients undergoing mechanical ventilation for > or = 48 hrs. After randomization, patients were allocated to one of the two following groups: a) heat and moisture exchangers (HMEs) changed every 24 hrs; b) HMEs changed only once a week. Devices in both groups could be changed at the discretion of the staff when signs of occlusion or increased resistance were identified. Efficient airway humidification and heating were assessed by clinical variables (numbers of tracheal suctionings and instillations required, peak and mean airway pressures). The frequency rates of bronchial colonization and ventilation-acquired pneumonia were evaluated by using clinical and microbiological criteria. Endotracheal tube occlusion, ventilatory support variables, duration of mechanical ventilation, length of intensive care, acquired multiorgan dysfunction, and mortality rates also were recorded. The two groups were similar at the time of randomization. Endotracheal tube occlusion never occurred. In the targeted population (patients ventilated for > or = 7 days), the frequency rate of ventilation-acquired pneumonia was 24% in the HME 1-day group and 17% in the HME 7-day group (p > .05, not significant). Ventilation-acquired pneumonia rates per 1000 ventilatory support days were 16.4/1000 in the HME 1-day group and 12.4/1000 in the HME 7-day group (p > .05, not significant). No statistically significant differences were found between the two groups for duration of mechanical ventilation, intensive care unit length of stay, acquired organ system derangements, and mortality rate. There was indirect evidence of very little, if any, change in HME resistance. Changing the studied hydrophobic HME after 7 days did not affect efficiency, increase resistance, or altered bacterial colonization. The frequency rate of ventilation-acquired pneumonia was also unchanged. Use of HMEs for > 24 hrs and up to 7 days is safe.
Norfolk, Stephanie G; Hollingsworth, Caroline L; Wolfe, Cameron R; Govert, Joseph A; Que, Loretta G; Cheifetz, Ira M; Hollingsworth, John W
2010-11-01
Severe respiratory failure is a well-recognized complication of pH1N1 influenza infection. Limited data regarding the efficacy of rescue therapies, including high-frequency oscillatory ventilation and extracorporeal membrane oxygenation, have been previously reported in the setting of pH1N1 influenza infection in the United States. Retrospective, single-center cohort study. Pediatric, cardiac, surgical, and medical intensive care units in a single tertiary care center in the United States. One hundred twenty-seven consecutive patients with confirmed influenza A infection requiring hospitalization between April 1, 2009, and October 31, 2009. Electronic medical records were reviewed for demographic and clinical data. The number of intensive care unit admissions appears inversely related to age with 39% of these admissions <20 yrs of age. Median duration of intensive care unit care was 10.0 days (4.0-24.0), and median duration of mechanical ventilation was 8.0 days (0.0-23.5). Rescue therapy (high-frequency oscillatory ventilation or extracorporeal membrane oxygenation) was used in 36% (12 of 33) of intensive care unit patients. The severity of respiratory impairment was determined by Pao²/Fio² ratio and oxygenation index. High-frequency oscillatory ventilation at 24 hrs resulted in improvements in median Pao²/Fio² ratio (71 [58-93] vs. 145 [126-185]; p < .001), oxygenation index (27 [20-30] vs. 18 [12-25]; p = .016), and Fio2 (100 [70-100] vs. 45 [40-55]; p < .001). Extracorporeal membrane oxygenation resulted in anticipated improvement in parameters of oxygenation at both 2 hrs and 24 hrs after initiation of therapy. Despite the severity of oxygenation impairment, overall survival for both rescue therapies was 75% (nine of 12), 80% (four of five) for high-frequency oscillatory ventilation alone, and 71% (five of seven) for high-frequency oscillatory ventilation + extracorporeal membrane oxygenation. In critically ill adult and pediatric patients with pH1N1 infection and severe lung injury, the use of high-frequency oscillatory ventilation and extracorporeal membrane oxygenation can result in significant improvements in Pao²/Fio² ratio, oxygenation index, and Fio². However, the impact on mortality is less certain.
A regulator for pressure-controlled total-liquid ventilation.
Robert, Raymond; Micheau, Philippe; Avoine, Olivier; Beaudry, Benoit; Beaulieu, Alexandre; Walti, Hervé
2010-09-01
Total-liquid ventilation (TLV) is an innovative experimental method of mechanical-assisted ventilation in which lungs are totally filled and then ventilated with a tidal volume of perfluorochemical liquid by using a dedicated liquid ventilator. Such a novel medical device must resemble other conventional ventilators: it must be able to conduct controlled-pressure ventilation. The objective was to design a robust controller to perform pressure-regulated expiratory flow and to implement it on our latest liquid-ventilator prototype (Inolivent-4). Numerical simulations, in vitro experiments, and in vivo experiments in five healthy term newborn lambs have demonstrated that it was efficient to generate expiratory flows while avoiding collapses. Moreover, the in vivo results have demonstrated that our liquid ventilator can maintain adequate gas exchange, normal acid-base equilibrium, and achieve greater minute ventilation, better oxygenation and CO2 extraction, while nearing flow limits. Hence, it is our suggestion to perform pressure-controlled ventilation during expiration with minute ventilation equal or superior to 140 mL x min(-1) x kg(-1) in order to ensure PaCO2 below 55 mmHg. From a clinician's point of view, pressure-controlled ventilation greatly simplifies the use of the liquid ventilator, which will certainly facilitate its introduction in intensive care units for clinical applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Heat recovery ventilators (HRVs) differ from other mechanical ventilation devices by their ability to exchange heat between supply and exhaust air streams, which reduces the cost of heating or cooling fresh air. This booklet discusses the need for mechanical ventilation in conventional and energy-efficient homes, an explains the components of a HRV system, how to operate and maintain the system, and how to solve operating problems. A maintenance chart and schedule and a HRV troubleshooting guide are included.
Modeling the resiliency of energy-efficient retrofits in low-income multifamily housing.
Underhill, L J; Fabian, M P; Vermeer, K; Sandel, M; Adamkiewicz, G; Leibler, J H; Levy, J I
2018-05-01
Residential energy efficiency and ventilation retrofits (eg, building weatherization, local exhaust ventilation, HVAC filtration) can influence indoor air quality (IAQ) and occupant health, but these measures' impact varies by occupant activity. In this study, we used the multizone airflow and IAQ analysis program CONTAM to simulate the impacts of energy retrofits on indoor concentrations of PM 2.5 and NO 2 in a low-income multifamily housing complex in Boston, Massachusetts (USA). We evaluated the differential impact of residential activities, such as low- and high-emission cooking, cigarette smoking, and window opening, on IAQ across two seasons. We found that a comprehensive package of energy and ventilation retrofits was resilient to a range of occupant activities, while less holistic approaches without ventilation improvements led to increases in indoor PM 2.5 or NO 2 for some populations. In general, homes with simulated concentration increases included those with heavy cooking and no local exhaust ventilation, and smoking homes without HVAC filtration. Our analytical framework can be used to identify energy-efficient home interventions with indoor retrofit resiliency (ie, those that provide IAQ benefits regardless of occupant activity), as well as less resilient retrofits that can be coupled with behavioral interventions (eg, smoking cessation) to provide cost-effective, widespread benefits. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Harun, D.; Zulfadhli; Akhyar, H.
2018-05-01
The turbine ventilator is a wind turbine with a vertical axis that has a combined function of the wind turbine and a suction fan. In this study, the turbine ventilator modified by adding a wind cup on the top (cap) turbine ventilator. The purpose of this experiment is to investigated the effect of the addition of wind cup on the turbine ventilator. Turbine ventilator used is type v30 and wind cup with diameter 77 mm. The experiment was conducted using a triangular pentagon model space chamber which was cut off to place the ventilator turbine ventilation cup with a volume of 0.983 m3 (equivalent to 1 mm3). The results of this study indicate that at an average wind speed of 1.8 m/s, the rotation of the turbine produced without a wind cup is 60.6 rpm while with the addition of a wind cup in the turbine ventilator is 69 rpm. The average increase of rotation turbine after added win cup is 8.4 rpm and the efficiency improvement of turbine ventilator is 1.7 %.
Urban ventilation corridors mapping using surface morphology data based GIS analysis
NASA Astrophysics Data System (ADS)
Wicht, Marzena; Wicht, Andreas; Osińska-Skotak, Katarzyna
2017-04-01
This paper describes deriving the most appropriate method for mapping urban ventilation corridors, which, if properly designed, reduce heat stress, air pollution and increase air quality, as well as increase the horizontal wind speed. Urban areas are - in terms of surface texture - recognized as one of the roughest surfaces, which results in wind obstruction and decreased ventilation of densely built up areas. As urban heat islands, private household and traffic emissions or large scale industries occur frequently in many cities, both in temperate and tropical regions. A proper ventilation system has been suggested as an appropriate mitigation mean [1] . Two concepts of morphometric analyses of the urban environment are used on the example of Warsaw, representing a dense, urban environment, located in the temperate zone. The utilized methods include firstly a roughness mapping calculation [2] , which analyses zero plane displacement height (zd) and roughness length (z0) and their distribution for the eight (inter-)cardinal wind directions and secondly a grid-based frontal area index mapping approach [3] , which uses least cost path analysis. Utilizing the advantages and minimizing the disadvantages of those two concepts, we propose a hybrid approach. All concepts are based on a 3D building database obtained from satellite imagery, aided by a cadastral building database. Derived areas (ventilation corridors), that facilitate the ventilation system, should be considered by the local authorities as worth preserving, if not expanding, in order to improve the air quality in the city. The results also include designation of the problematic areas, which greatly obscure the ventilation and might be investigated as to reshape or rebuilt to introduce the air flow in particularly dense areas like city centers. Keywords: roughness mapping; GIS; ventilation corridors; frontal area index Rizwan, A. M., Dennis, L. Y., & Chunho, L. I. U. (2008). A review on the generation, determination and mitigation of Urban Heat Island. Journal of Environmental Sciences, 20(1), 120-128. Gál, T., & Unger, J. (2009). Detection of ventilation paths using high-resolution roughness parameter mapping in a large urban area. Building and Environment, 44(1), 198-206. Wong, M. S., Nichol, J. E., To, P. H., & Wang, J. (2010). A simple method for designation of urban ventilation corridors and its application to urban heat island analysis. Building and Environment, 45(8), 1880-1889.
Cheng, Y; Lin, Z
2015-12-01
The motivation of this study is stimulated by a lack of knowledge about the difference of airflow characteristics between a novel air distribution method [i.e., stratum ventilation (SV)] and conventional air distribution methods [i.e., mixing ventilation (MV) and displacement ventilation (DV)]. Detailed air velocity and temperature measurements were conducted in the occupied zone of a classroom with dimensions of 8.8 m (L) × 6.1 m (W) × 2.4 m (H). Turbulence intensity and power spectrum of velocity fluctuation were calculated using the measured data. Thermal comfort and cooling efficiency were also compared. The results show that in the occupied zone, the airflow characteristics among MV, DV, and SV are different. The turbulent airflow fluctuation is enhanced in this classroom with multiple thermal manikins due to thermal buoyancy and airflow mixing effect. Thermal comfort evaluations indicate that in comparison with MV and DV, a higher supply air temperature should be adopted for SV to achieve general thermal comfort with low draft risk. Comparison of the mean air temperatures in the occupied zone reveals that SV is of highest cooling efficiency, followed by DV and then MV. This study reports the unique profiles of flow, temperature, turbulence intensity, and power spectrum of stratum ventilation, which can have a number of implications for both knowledge and understanding of the flow characteristics in a stratum-ventilated room. With respect to the former, it expounds the fundamental characteristics of this air distribution method; and with respect to the latter, it reveals the mechanism of thermal comfort and energy saving under stratum ventilation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Particle transport in low-energy ventilation systems. Part 2: Transients and experiments.
Bolster, D T; Linden, P F
2009-04-01
Providing adequate indoor air quality while reducing energy consumption is a must for efficient ventilation system design. In this work, we study the transport of particulate contaminants in a displacement-ventilated space, using the idealized 'emptying filling box' model (P.F. Linden, G.F. Lane-serff and D.A. Smeed (1990) Emptying filling boxes: the fluid mechanics of natural ventilation, J. fluid Mech., 212, 309-335.). In this paper, we focused on transient contaminant transport by modeling three transient contamination scenarios, namely the so called 'step-up', 'step-down', and point source cases. Using analytical integral models and numerical models we studied the transient behavior of each of these three cases. We found that, on average, traditional and low-energy systems can be similar in overall pollutant removal efficiency, although quite different vertical gradients can exist. This plays an important role in estimating occupant exposure to contaminant. A series of laboratory experiments were conducted to validate the developed models. The results presented here illustrate that the source location plays a very important role in the distribution of contaminant concentration for spaces ventilated by low energy displacement-ventilation systems. With these results and the knowledge of typical contaminant sources for a given type of space practitioners can design or select more effective systems for the purpose at hand.
Indoor environment program. 1994 annual report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daisey, J.M.
1995-04-01
Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, andmore » energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.« less
Transfer factor, lung volumes, resistance and ventilation distribution in healthy adults.
Verbanck, Sylvia; Van Muylem, Alain; Schuermans, Daniel; Bautmans, Ivan; Thompson, Bruce; Vincken, Walter
2016-01-01
Monitoring of chronic lung disease requires reference values of lung function indices, including putative markers of small airway function, spanning a wide age range.We measured spirometry, transfer factor of the lung for carbon monoxide (TLCO), static lung volume, resistance and ventilation distribution in a healthy population, studying at least 20 subjects per sex and per decade between the ages of 20 and 80 years.With respect to the Global Lung Function Initiative reference data, our subjects had average z-scores for forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC of -0.12, 0.04 and -0.32, respectively. Reference equations were obtained which could account for a potential dependence of index variability on age and height. This was done for (but not limited to) indices that are pertinent to asthma and chronic obstructive pulmonary disease studies: forced expired volume in 6 s, forced expiratory flow, TLCO, specific airway conductance, residual volume (RV)/total lung capacity (TLC), and ventilation heterogeneity in acinar and conductive lung zones.Deterioration in acinar ventilation heterogeneity and lung clearance index with age were more marked beyond 60 years, and conductive ventilation heterogeneity showed the greatest increase in variability with age. The most clinically relevant deviation from published reference values concerned RV/TLC values, which were considerably smaller than American Thoracic Society/European Respiratory Society-endorsed reference values. Copyright ©ERS 2016.
Moustafa, Islam O F; Ali, Mohammed R A-A; Al Hallag, Moataz; Rabea, Hoda; Fink, James B; Dailey, Patricia; Abdelrahim, Mohamed E A
During mechanical ventilation medical aerosol delivery has been reported to be upto two fold greater with dry inhaled gas than with heated humidity. Urine levels at 0.5 h post dose (URSAL0.5%) has been confirmed as an index of lung deposition and 24 h (URSAL24%) as index of systemic absorption. Our aim was to determine the effect of humidification and aerosol device type on drug delivery to ventilated patients using urine levels. In a randomized crossover design, 36 (18female) mechanically ventilated patients were assigned to one of three groups. Groups 1 and 2 received 5000 μg salbutamol using vibrating mesh (VM) and jet nebulizers (JN), respectively, while group 3 received 1600 μg (16 puffs) of salbutamol via metered dose inhaler with AeroChamber Vent (MDI-AV). All devices were placed in the inspiratory limb of ventilator downstream from the humidifier. Each subject received aerosol with and without humidity at >24 h intervals with >12 h washout periods between salbutamol doses. Patients voided urine 15 min before each study dose and urine samples were collected at 0.5 h post dosing and pooled for the next 24 h. The MDI-AV and VM resulted in a higher percentage of urinary salbutamol levels compared to the JN (p < 0.05). Urine levels were similar between humidity and dry conditions. Our findings suggest that in-vitro reports overestimate the impact of dry vs. heated humidified conditions on the delivery of aerosol during invasive mechanical ventilation. Copyright © 2017 Elsevier Inc. All rights reserved.
dos Reis, Helena França Correia; Almeida, Mônica Lajana Oliveira; da Silva, Mário Ferreira; Moreira, Julião Oliveira; Rocha, Mário de Seixas
2013-01-01
Objective To investigate the association between the rapid shallow breathing index and successful extubation in patients with traumatic brain injury. Methods This study was a prospective study conducted in patients with traumatic brain injury of both genders who underwent mechanical ventilation for at least two days and who passed a spontaneous breathing trial. The minute volume and respiratory rate were measured using a ventilometer, and the data were used to calculate the rapid shallow breathing index (respiratory rate/tidal volume). The dependent variable was the extubation outcome: reintubation after up to 48 hours (extubation failure) or not (extubation success). The independent variable was the rapid shallow breathing index measured after a successful spontaneous breathing trial. Results The sample comprised 119 individuals, including 111 (93.3%) males. The average age of the sample was 35.0±12.9 years old. The average duration of mechanical ventilation was 8.1±3.6 days. A total of 104 (87.4%) participants achieved successful extubation. No association was found between the rapid shallow breathing index and extubation success. Conclusion The rapid shallow breathing index was not associated with successful extubation in patients with traumatic brain injury. PMID:24213084
Aerosol delivery with two ventilation modes during mechanical ventilation: a randomized study.
Dugernier, Jonathan; Reychler, Gregory; Wittebole, Xavier; Roeseler, Jean; Depoortere, Virginie; Sottiaux, Thierry; Michotte, Jean-Bernard; Vanbever, Rita; Dugernier, Thierry; Goffette, Pierre; Docquier, Marie-Agnes; Raftopoulos, Christian; Hantson, Philippe; Jamar, François; Laterre, Pierre-François
2016-12-01
Volume-controlled ventilation has been suggested to optimize lung deposition during nebulization although promoting spontaneous ventilation is targeted to avoid ventilator-induced diaphragmatic dysfunction. Comparing topographic aerosol lung deposition during volume-controlled ventilation and spontaneous ventilation in pressure support has never been performed. The aim of this study was to compare lung deposition of a radiolabeled aerosol generated with a vibrating-mesh nebulizer during invasive mechanical ventilation, with two modes: pressure support ventilation and volume-controlled ventilation. Seventeen postoperative neurosurgery patients without pulmonary disease were randomly ventilated in pressure support or volume-controlled ventilation. Diethylenetriaminepentaacetic acid labeled with technetium-99m (2 mCi/3 mL) was administrated using a vibrating-mesh nebulizer (Aerogen Solo(®), provided by Aerogen Ltd, Galway, Ireland) connected to the endotracheal tube. Pulmonary and extrapulmonary particles deposition was analyzed using planar scintigraphy. Lung deposition was 10.5 ± 3.0 and 15.1 ± 5.0 % of the nominal dose during pressure support and volume-controlled ventilation, respectively (p < 0.05). Higher endotracheal tube and tracheal deposition was observed during pressure support ventilation (27.4 ± 6.6 vs. 20.7 ± 6.0 %, p < 0.05). A similar penetration index was observed for the right (p = 0.210) and the left lung (p = 0.211) with both ventilation modes. A high intersubject variability of lung deposition was observed with both modes regarding lung doses, aerosol penetration and distribution between the right and the left lung. In the specific conditions of the study, volume-controlled ventilation was associated with higher lung deposition of nebulized particles as compared to pressure support ventilation. The clinical benefit of this effect warrants further studies. Clinical trial registration NCT01879488.
Regenerative Blower for EVA Suit Ventilation Fan
NASA Technical Reports Server (NTRS)
Izenson, Michael G.; Chen, Weibo; Paul, Heather L.
2010-01-01
Portable life support systems in future space suits will include a ventilation subsystem driven by a dedicated fan. This ventilation fan must meet challenging requirements for pressure rise, flow rate, efficiency, size, safety, and reliability. This paper describes research and development that showed the feasibility of a regenerative blower that is uniquely suited to meet these requirements. We proved feasibility through component tests, blower tests, and design analysis. Based on the requirements for the Constellation Space Suit Element (CSSE) Portable Life Support System (PLSS) ventilation fan, we designed the critical elements of the blower. We measured the effects of key design parameters on blower performance using separate effects tests, and used the results of these tests to design a regenerative blower that will meet the ventilation fan requirements. We assembled a proof-of-concept blower and measured its performance at sub-atmospheric pressures that simulate a PLSS ventilation loop environment. Head/flow performance and maximum efficiency point data were used to specify the design and operating conditions for the ventilation fan. We identified materials for the blower that will enhance safety for operation in a lunar environment, and produced a solid model that illustrates the final design. The proof-of-concept blower produced the flow rate and pressure rise needed for the CSSE ventilation subsystem while running at 5400 rpm, consuming only 9 W of electric power using a non-optimized, commercial motor and controller and inefficient bearings. Scaling the test results to a complete design shows that a lightweight, compact, reliable, and low power regenerative blower can meet the performance requirements for future space suit life support systems.
In vitro and in vivo evaluation of a new active heat moisture exchanger
Chiumello, Davide; Pelosi, Paolo; Park, Gilbert; Candiani, Andrea; Bottino, Nicola; Storelli, Ezio; Severgnini, Paolo; D'Onofrio, Dunia; Gattinoni, Luciano; Chiaranda, Massimo
2004-01-01
Introduction In order to improve the efficiency of heat moisture exchangers (HMEs), new hybrid humidifiers (active HMEs) that add water and heat to HMEs have been developed. In this study we evaluated the efficiency, both in vitro and in vivo, of a new active HME (the Performer; StarMed, Mirandola, Italy) as compared with that of existing HMEs (Hygroster and Hygrobac; Mallinckrodt, Mirandola, Italy). Methods We tested the efficiency by measuring the temperature and absolute humidity (AH) in vitro using a test lung ventilated at three levels of minute ventilation (5, 10 and 15 l/min) and at two tidal volumes (0.5 and 1 l), and in vivo in 42 patients with acute lung injury (arterial oxygen tension/fractional inspired oxygen ratio 283 ± 72 mmHg). We also evaluated the efficiency in vivo after 12 hours. Results In vitro, passive Performer and Hygrobac had higher airway temperature and AH (29.2 ± 0.7°C and 29.2 ± 0.5°C, [P < 0.05]; AH: 28.9 ± 1.6 mgH2O/l and 28.1 ± 0.8 mgH2O/l, [P < 0.05]) than did Hygroster (airway temperature: 28.1 ± 0.3°C [P < 0.05]; AH: 27 ± 1.2 mgH2O/l [P < 0.05]). Both devices suffered a loss of efficiency at the highest minute ventilation and tidal volume, and at the lowest minute ventilation. Active Performer had higher airway temperature and AH (31.9 ± 0.3°C and 34.3 ± 0.6 mgH2O/l; [P < 0.05]) than did Hygrobac and Hygroster, and was not influenced by minute ventilation or tidal volume. In vivo, the efficiency of passive Performer was similar to that of Hygrobac but better than Hygroster, whereas Active Performer was better than both. The active Performer exhibited good efficiency when used for up to 12 hours in vivo. Conclusion This study showed that active Performer may provide adequate conditioning of inspired gases, both as a passive and as an active device. PMID:15469569
In vitro and in vivo evaluation of a new active heat moisture exchanger.
Chiumello, Davide; Pelosi, Paolo; Park, Gilbert; Candiani, Andrea; Bottino, Nicola; Storelli, Ezio; Severgnini, Paolo; D'Onofrio, Dunia; Gattinoni, Luciano; Chiaranda, Massimo
2004-10-01
In order to improve the efficiency of heat moisture exchangers (HMEs), new hybrid humidifiers (active HMEs) that add water and heat to HMEs have been developed. In this study we evaluated the efficiency, both in vitro and in vivo, of a new active HME (the Performer; StarMed, Mirandola, Italy) as compared with that of existing HMEs (Hygroster and Hygrobac; Mallinckrodt, Mirandola, Italy). We tested the efficiency by measuring the temperature and absolute humidity (AH) in vitro using a test lung ventilated at three levels of minute ventilation (5, 10 and 15 l/min) and at two tidal volumes (0.5 and 1 l), and in vivo in 42 patients with acute lung injury (arterial oxygen tension/fractional inspired oxygen ratio 283 +/- 72 mmHg). We also evaluated the efficiency in vivo after 12 hours. In vitro, passive Performer and Hygrobac had higher airway temperature and AH (29.2 +/- 0.7 degrees C and 29.2 +/- 0.5 degrees C, [P < 0.05]; AH: 28.9 +/- 1.6 mgH2O/l and 28.1 +/- 0.8 mgH2O/l, [P < 0.05]) than did Hygroster (airway temperature: 28.1 +/- 0.3 degrees C [P < 0.05]; AH: 27 +/- 1.2 mgH2O/l [P < 0.05]). Both devices suffered a loss of efficiency at the highest minute ventilation and tidal volume, and at the lowest minute ventilation. Active Performer had higher airway temperature and AH (31.9 +/- 0.3 degrees C and 34.3 +/- 0.6 mgH2O/l; [P < 0.05]) than did Hygrobac and Hygroster, and was not influenced by minute ventilation or tidal volume. In vivo, the efficiency of passive Performer was similar to that of Hygrobac but better than Hygroster, whereas Active Performer was better than both. The active Performer exhibited good efficiency when used for up to 12 hours in vivo. This study showed that active Performer may provide adequate conditioning of inspired gases, both as a passive and as an active device.
[Oxidative stress in patients on mechanical ventilation].
Marjanović, Vesna; Dordević, Vidosava; Marjanović, Goran
2009-01-01
The appearance and intensity of oxidative stress were analyzed in the course of mechanical ventilation and parameters that could point toward potential lung damage. In three time intervals on day 1, 3 and 7 of mechanical ventilation, parameters such as: triglycerides, cholesterol, lactate, serum lactic dehydrogenase, acid-base balance and lipid peroxidation products--thiobarbituric acid reactive substances, were followed in 30 patients with head injuries. A decrease in the level of partial oxygen pressure (PaO2) (p < 0.01) and PaO2/FiO2 index (p < 0.05) in arterial blood was recorded on day 3 of mechanical ventilation. This was accompanied with an increase in alveolar-arterial difference (AaDO2) (p < 0.05), thiobarbituric acid reactive substances (p < 0.001) and lactic dehydrogenase (p < 0.001) comparing to day 1 of mechanical ventilation. The patients with initial PaO2 > 120 mmHg, had significant increase of thiobarbituric acid reactive substances and AaDO2 (p < 0.05) and fall of PaO2 (p < 0.001) on day 3 of mechanical ventilation. Oxidative stress and lipid peroxide production are increased during third day of mechanical ventilation leading to disruption of oxygen diffusion through alveolar-capillary membrane and reduction of parameters of oxygenation.
Improved OCT imaging of lung tissue using a prototype for total liquid ventilation
NASA Astrophysics Data System (ADS)
Schnabel, Christian; Meissner, Sven; Koch, Edmund
2011-06-01
Optical coherence tomography (OCT) is used for imaging subpleural alveoli in animal models to gain information about dynamic and morphological changes of lung tissue during mechanical ventilation. The quality of OCT images can be increased if the refraction index inside the alveoli is matched to the one of tissue via liquid-filling. Thereby, scattering loss can be decreased and higher penetration depth and tissue contrast can be achieved. Until now, images of liquid-filled lungs were acquired in isolated and fixated lungs only, so that an in vivo measurement situation is not present. To use the advantages of liquid-filling for in vivo imaging of small rodent lungs, it was necessary to develop a liquid ventilator. Perfluorodecalin, a perfluorocarbon, was selected as breathing fluid because of its refraction index being similar to the one of water and the high transport capacity for carbon dioxide and oxygen. The setup is characterized by two independent syringe pumps to insert and withdraw the fluid into and from the lung and a custom-made control program for volume- or pressure-controlled ventilation modes. The presented results demonstrate the liquid-filling verified by optical coherence tomography and intravital microscopy (IVM) and the advantages of liquid-filling to OCT imaging of subpleural alveoli.
The Integrative Weaning Index in Elderly ICU Subjects.
Azeredo, Leandro M; Nemer, Sérgio N; Barbas, Carmen Sv; Caldeira, Jefferson B; Noé, Rosângela; Guimarães, Bruno L; Caldas, Célia P
2017-03-01
With increasing life expectancy and ICU admission of elderly patients, mechanical ventilation, and weaning trials have increased worldwide. We evaluated a cohort with 479 subjects in the ICU. Patients younger than 18 y, tracheostomized, or with neurologic diseases were excluded, resulting in 331 subjects. Subjects ≥70 y old were considered elderly, whereas those <70 y old were considered non-elderly. Besides the conventional weaning indexes, we evaluated the performance of the integrative weaning index (IWI). The probability of successful weaning was investigated using relative risk and logistic regression. The Hosmer-Lemeshow goodness-of-fit test was used to calibrate and the C statistic was calculated to evaluate the association between predicted probabilities and observed proportions in the logistic regression model. Prevalence of successful weaning in the sample was 83.7%. There was no difference in mortality between elderly and non-elderly subjects ( P = .16), in days of mechanical ventilation ( P = .22) and days of weaning ( P = .55). In elderly subjects, the IWI was the only respiratory variable associated with mechanical ventilation weaning in this population ( P < .001). The IWI was the independent variable found in weaning of elderly subjects that may contribute to the critical moment of this population in intensive care. Copyright © 2017 by Daedalus Enterprises.
Thermoregulation and ventilation of termite mounds.
Korb, Judith
2003-05-01
Some of the most sophisticated of all animal-built structures are the mounds of African termites of the subfamily Macrotermitinae, the fungus-growing termites. They have long been studied as fascinating textbook examples of thermoregulation or ventilation of animal buildings. However, little research has been designed to provide critical tests of these paradigms, derived from a very small number of original papers. Here I review results from recent studies on Macrotermes bellicosus that considered the interdependence of ambient temperature, thermoregulation, ventilation and mound architecture, and that question some of the fundamental paradigms of termite mounds. M. bellicosus achieves thermal homeostasis within the mound, but ambient temperature has an influence too. In colonies in comparably cool habitats, mound architecture is adapted to reduce the loss of metabolically produced heat to the environment. While this has no negative consequences in small colonies, it produces a trade-off with gas exchange in large colonies, resulting in suboptimally low nest temperatures and increased CO(2) concentrations. Along with the alteration in mound architecture, the gas exchange/ventilation mechanism also changes. While mounds in the thermally appropriate savannah have a very efficient circular ventilation during the day, the ventilation in the cooler forest is a less efficient upward movement of air, with gas exchange restricted by reduced surface exchange area. These results, together with other recent findings, question entrenched ideas such as the thermosiphon-ventilation mechanism or the assumption that mounds function to dissipate internally produced heat. Models trying to explain the proximate mechanisms of mound building, or building elements, are discussed.
Thermoregulation and ventilation of termite mounds
NASA Astrophysics Data System (ADS)
Korb, Judith
2003-05-01
Some of the most sophisticated of all animal-built structures are the mounds of African termites of the subfamily Macrotermitinae, the fungus-growing termites. They have long been studied as fascinating textbook examples of thermoregulation or ventilation of animal buildings. However, little research has been designed to provide critical tests of these paradigms, derived from a very small number of original papers. Here I review results from recent studies on Macrotermes bellicosus that considered the interdependence of ambient temperature, thermoregulation, ventilation and mound architecture, and that question some of the fundamental paradigms of termite mounds. M. bellicosus achieves thermal homeostasis within the mound, but ambient temperature has an influence too. In colonies in comparably cool habitats, mound architecture is adapted to reduce the loss of metabolically produced heat to the environment. While this has no negative consequences in small colonies, it produces a trade-off with gas exchange in large colonies, resulting in suboptimally low nest temperatures and increased CO2 concentrations. Along with the alteration in mound architecture, the gas exchange/ventilation mechanism also changes. While mounds in the thermally appropriate savannah have a very efficient circular ventilation during the day, the ventilation in the cooler forest is a less efficient upward movement of air, with gas exchange restricted by reduced surface exchange area. These results, together with other recent findings, question entrenched ideas such as the thermosiphon-ventilation mechanism or the assumption that mounds function to dissipate internally produced heat. Models trying to explain the proximate mechanisms of mound building, or building elements, are discussed.
Energy efficiency evaluation of hospital building office
NASA Astrophysics Data System (ADS)
Fitriani, Indah; Sangadji, Senot; Kristiawan, S. A.
2017-01-01
One of the strategy employed in building design is reducing energy consumption while maintaining the best comfort zone in building indoor climate. The first step to improve office buildings energy performance by evaluating its existing energy usage using energy consumption intensity (Intensitas Konsumsi Energi, IKE) index. Energy evaluation of office building for hospital dr. Sayidiman at Kabupaten Magetan has been carried out in the initial investigation. The office building is operated with active cooling (air conditioning, AC) and use limited daylighting which consumes 14.61 kWh/m2/month. This IKE value is attributed into a slightly inefficient category. Further investigation was carried out by modeling and simulating thermal energy load and room lighting in every building zone using of Ecotect from Autodesk. Three scenarios of building energy and lighting retrofit have been performed simulating representing energy efficiency using cross ventilation, room openings, and passive cooling. The results of the numerical simulation indicate that the third scenario by employing additional windows, reflector media and skylight exhibit the best result and in accordance with SNI 03-6575-2001 lighting standard. Total thermal load of the existing building which includes fabric gains, indirect solar gains, direct solar gains, ventilation fans, internal gains, inter-zonal gains and cooling load were 162,145.40 kWh. Based on the three scenarios, the thermal load value (kWh) obtained was lowest achieved scenario 2 with the thermal value of 117,539.08 kWh.The final results are interpreted from the total energy emissions evaluated using the Ecotect software, the heating and cooling demand value and specific design of the windows are important factors to determine the energy efficiency of the buildings.
Sethi, Sidharth K; Raghunathan, Veena; Shah, Shilpi; Dhaliwal, Maninder; Jha, Pranaw; Kumar, Maneesh; Paluri, Sravanthi; Bansal, Shyam; Mhanna, Maroun J; Raina, Rupesh
2018-01-01
Objectives: We investigated the association of fluid overload and oxygenation in critically sick children, and their correlation with various outcomes (duration of ventilation, ICU stay, and mortality). We also assessed whether renal angina index (RAI) at admission can predict mortality or acute kidney injury (AKI) on day 3 after admission. Design and setting: Prospective study, pediatric intensive care in a tertiary hospital. Duration: June 2013-June 2014. Patients: Patients were included if they needed invasive mechanical ventilation for >24 h and had an indwelling arterial catheter. Patients with congenital heart disease or those who received renal replacement therapy (RRT) were excluded. Methods: Oxygenation index, fluid overload percent (daily, cumulative), RAI at admission and pediatric logistic organ dysfunction (PELOD) score were obtained in all critically ill children. KDIGO classification was used to define AKI, using both creatinine and urine output criteria. Admission data for determination of RAI included the use of vasopressors, invasive mechanical ventilation, percent fluid overload, and change in kidney function (estimated creatinine clearance). Univariable and multivariable approaches were used to assess the relations between fluid overload, oxygenation index and clinical outcomes. An RAI cutoff >8 was used to predict AKI on day 3 of admission and mortality. Results: One hundred and two patients were recruited. Fluid overload predicted oxygenation index in all patients, independent of age, gender and PELOD score ( p < 0.05). Fluid overload was associated with longer duration of ventilation ( p < 0.05), controlled for age, gender, and PELOD score. Day-3 AKI rates were higher in patients with a RAI of 8 or more, and higher areas under the RAI curve had better prediction rates for Day-3 AKI. An RAI <8 had high negative predictive values (80-95%) for Day-3 AKI. RAI was better than traditional markers of pediatric severity of illness (PELOD) score for prediction of AKI on day 3. Conclusions: This study emphasizes that positive fluid balance adversely affects intensive care in critically ill children. Further, the RAI prediction model may help optimize treatment and improve clinical prediction of AKI.
Sethi, Sidharth K.; Raghunathan, Veena; Shah, Shilpi; Dhaliwal, Maninder; Jha, Pranaw; Kumar, Maneesh; Paluri, Sravanthi; Bansal, Shyam; Mhanna, Maroun J.; Raina, Rupesh
2018-01-01
Objectives: We investigated the association of fluid overload and oxygenation in critically sick children, and their correlation with various outcomes (duration of ventilation, ICU stay, and mortality). We also assessed whether renal angina index (RAI) at admission can predict mortality or acute kidney injury (AKI) on day 3 after admission. Design and setting: Prospective study, pediatric intensive care in a tertiary hospital. Duration: June 2013-June 2014. Patients: Patients were included if they needed invasive mechanical ventilation for >24 h and had an indwelling arterial catheter. Patients with congenital heart disease or those who received renal replacement therapy (RRT) were excluded. Methods: Oxygenation index, fluid overload percent (daily, cumulative), RAI at admission and pediatric logistic organ dysfunction (PELOD) score were obtained in all critically ill children. KDIGO classification was used to define AKI, using both creatinine and urine output criteria. Admission data for determination of RAI included the use of vasopressors, invasive mechanical ventilation, percent fluid overload, and change in kidney function (estimated creatinine clearance). Univariable and multivariable approaches were used to assess the relations between fluid overload, oxygenation index and clinical outcomes. An RAI cutoff >8 was used to predict AKI on day 3 of admission and mortality. Results: One hundred and two patients were recruited. Fluid overload predicted oxygenation index in all patients, independent of age, gender and PELOD score (p < 0.05). Fluid overload was associated with longer duration of ventilation (p < 0.05), controlled for age, gender, and PELOD score. Day-3 AKI rates were higher in patients with a RAI of 8 or more, and higher areas under the RAI curve had better prediction rates for Day-3 AKI. An RAI <8 had high negative predictive values (80–95%) for Day-3 AKI. RAI was better than traditional markers of pediatric severity of illness (PELOD) score for prediction of AKI on day 3. Conclusions: This study emphasizes that positive fluid balance adversely affects intensive care in critically ill children. Further, the RAI prediction model may help optimize treatment and improve clinical prediction of AKI. PMID:29765932
Verriele, M; Schoemaecker, C; Hanoune, B; Leclerc, N; Germain, S; Gaudion, V; Locoge, N
2016-10-01
Indoor air quality was characterized in 10 recently built energy-efficient French schools during two periods of 4.5 days. Carbon dioxide time-resolved measurements during occupancy clearly highlight the key role of the ventilation rate (scheduled or occupancy indexed), especially in this type of building, which was tightly sealed and equipped with a dual-flow ventilation system to provide air refreshment. Volatile organic compounds (VOCs) and inorganic gases (ozone and NO2 ) were measured indoors and outdoors by passive techniques during the occupied and the unoccupied periods. Over 150 VOC species were identified. Among them, 27 species were selected for quantification, based on their occurrence. High concentrations were found for acetone, 2-butanone, formaldehyde, toluene, and hexaldehyde. However, these concentrations are lower than those previously observed in conventional school buildings. The indoor/outdoor and unoccupied/occupied ratios are informative regarding emission sources. Except for benzene, ozone, and NO2 , all the pollutants in these buildings have an indoor source. Occupancy is associated with increased levels of acetone, 2-butanone, pentanal, butyl acetate, and alkanes. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Zhang, Jian; Chen, Chao Qin; Lei, Xiu Zhen; Feng, Zhi Ying; Zhu, Sheng Mei
2013-07-01
This pilot study was designed to utilize stroke volume variation and cardiac index to ensure fluid optimization during one-lung ventilation in patients undergoing thoracoscopic lobectomies. Eighty patients undergoing thoracoscopic lobectomy were randomized into either a goal-directed therapy group or a control group. In the goal-directed therapy group, the stroke volume variation was controlled at 10%±1%, and the cardiac index was controlled at a minimum of 2.5 L.min-1.m-2. In the control group, the MAP was maintained at between 65 mm Hg and 90 mm Hg, heart rate was maintained at between 60 BPM and 100 BPM, and urinary output was greater than 0.5 mL/kg-1/h-1. The hemodynamic variables, arterial blood gas analyses, total administered fluid volume and side effects were recorded. The PaO2/FiO2-ratio before the end of one-lung ventilation in the goal-directed therapy group was significantly higher than that of the control group, but there were no differences between the goal-directed therapy group and the control group for the PaO2/FiO2-ratio or other arterial blood gas analysis indices prior to anesthesia. The extubation time was significantly earlier in the goal-directed therapy group, but there was no difference in the length of hospital stay. Patients in the control group had greater urine volumes, and they were given greater colloid and overall fluid volumes. Nausea and vomiting were significantly reduced in the goal-directed therapy group. The results of this study demonstrated that an optimization protocol, based on stroke volume variation and cardiac index obtained with a FloTrac/Vigileo device, increased the PaO2/FiO2-ratio and reduced the overall fluid volume, intubation time and postoperative complications (nausea and vomiting) in thoracic surgery patients requiring one-lung ventilation.
NASA Astrophysics Data System (ADS)
Harun, S. I.; Idris, S. R. A.; Tamar Jaya, N.
2017-09-01
Local exhaust ventilation (LEV) is an engineering system frequently used in the workplace to protect operators from hazardous substances. The objective of this project is design and fabricate the ventilation system as installation for chamber room of laser cutting machine and to stimulate the air flow inside chamber room of laser cutting machine with the ventilation system that designed. LEV’s fabricated with rated voltage D.C 10.8V and 1.5 ampere. Its capacity 600 ml, continuously use limit approximately 12-15 minute, overall length LEV’s fabricated is 966 mm with net weight 0.88 kg and maximum airflow is 1.3 meter cubic per minute. Stimulate the air flow inside chamber room of laser cutting machine with the ventilation system that designed and fabricated overall result get 2 main gas vapor which air and carbon dioxide. For air gas which experimented by using anemometer, general duct velocity that produce is same with other gas produce, carbon dioxide which 5 m/s until 10 m/s. Overall result for 5 m/s and 10 m/s as minimum and maximum duct velocity produce for both air and carbon dioxide. The air gas flow velocity that captured by LEV’s fabricated, 3.998 m/s average velocity captured from 5 m/s duct velocity which it efficiency of 79.960% and 7.667 m/s average velocity captured from 10 m/s duct velocity with efficiency of 76.665%. For carbon dioxide gas flow velocity that captured by LEV’s fabricated, 3.674 m/s average velocity captured from 5 m/s duct velocity which it efficiency of 73.480% and 8.255 m/s average velocity captured from 10 m/s duct velocity with efficiency of 82.545%.
Zhou, Min; Dai, Ji; Du, Min; Wang, Wei; Guo, Changxing; Wang, Yi; Tang, Rui; Xu, Fengling; Rao, Zhuqing; Sun, Gengyun
2016-08-01
The role of dobutamine in the relief of pulmonary edema during septic shock-induced acute respiratory distress syndrome (ARDS) remains undetermined, due to a lack of controllable and quantitative clinical studies. Our objective was to assess the potential effects of dobutamine on extravascular lung water index (ELWI) in septic shock-induced ARDS, reflecting its importance in pulmonary edema. At the same time, ventilator function and perfusion parameters were evaluated. We designed a prospective, non-randomized, non-blinded, controlled study to compare the differences in PiCCO parameters after 6 h of constant dobutamine infusion (15 μg/kg/min), in the baseline parameters in 26 septic shock-related ARDS patients with cardiac index ≥ 2.5I/min/m(2) and hyperlactatemia. These patients (12 survivors/14 non-survivors) were monitored using the PiCCO catheter system within 48 h of onset of septic shock. The dynamic changes in ELWI, which is typically used for quantifying the extent of pulmonary edema, were evaluated, and the corresponding ventilator function and tissue perfusion parameters were also measured. Decreasing ELWI (p = 0.0376) was accompanied by significantly decreased SVRI (p < 0.0001). Despite a significant increase in cardiac output (p < 0.0001), no differences were found in ITBI or GEDI. Moreover, the required dose of norepinephrine was decreased (p = 0.0389), and urine output was increased (p = 0.0358), accompanied by stabilized lactacidemia and MAP. Additionally, airway pressure was moderately improved. During the early stage of septic shock-induced ARDS, dobutamine treatment demonstrated a beneficial effect by relieving pulmonary edema in patients, without a negative elevation in preload or hemodynamics, which might account for the improvements in ventilator function and tissue hypoperfusion.
Ferrando, Carlos; Mugarra, Ana; Gutierrez, Andrea; Carbonell, Jose Antonio; García, Marisa; Soro, Marina; Tusman, Gerardo; Belda, Francisco Javier
2014-03-01
We investigated whether individualized positive end-expiratory pressure (PEEP) improves oxygenation, ventilation, and lung mechanics during one-lung ventilation compared with standardized PEEP. Thirty patients undergoing thoracic surgery were randomly allocated to the study or control group. Both groups received an alveolar recruitment maneuver at the beginning and end of one-lung ventilation. After the alveolar recruitment maneuver, the control group had their lungs ventilated with a 5 cm·H2O PEEP, while the study group had their lungs ventilated with an individualized PEEP level determined by a PEEP decrement trial. Arterial blood samples, lung mechanics, and volumetric capnography were recorded at multiple timepoints throughout the procedure. The individualized PEEP values in study group were higher than the standardized PEEP values (10 ± 2 vs 5 cm·H2O; P < 0.001). In both groups, arterial oxygenation decreased when bilateral-lung ventilation was switched to one-lung ventilation and increased after the alveolar recruitment maneuver. During one-lung ventilation, oxygenation was maintained in the study group but decreased in the control group. After one-lung ventilation, arterial oxygenation was significantly higher in the study group (306 vs 231 mm·Hg, P = 0.007). Static compliance decreased in both groups when bilateral-lung ventilation was switched to one-lung ventilation. Static compliance increased significantly only in the study group (P < 0.001) after the alveolar recruitment maneuver and optimal PEEP adjustment. The alveolar recruitment maneuver did not decrease cardiac index in any patient. During one-lung ventilation, the improvements in oxygenation and lung mechanics after an alveolar recruitment maneuver were better preserved by ventilation by using individualized PEEP with a PEEP decrement trial than with a standardized 5 cm·H2O of PEEP.
High Performance Mars Liquid Cooling and Ventilation Garment Project
NASA Technical Reports Server (NTRS)
Terrier, Douglas; Clayton, Ronald; Whitlock, David; Conger, Bruce
2015-01-01
EVA space suit mobility in micro-gravity is enough of a challenge and in the gravity of Mars, improvements in mobility will enable the suited crew member to efficiently complete EVA objectives. The idea proposed is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area in order to free up the arms and legs by removing the liquid tubes currently used in the ISS EVA suit in the limbs. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased to provide the entire liquid cooling requirement and increase mobility by freeing up the arms and legs. Additional potential benefits of this approach include reduced LCVG mass, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development.
NASA Astrophysics Data System (ADS)
Khalqihi, K. I.; Rahayu, M.; Rendra, M.
2017-12-01
PT Perkebunan Nusantara VIII Ciater is a company produced black tea orthodox more or less 4 tons every day. At the production section, PT Perkebunan Nusantara VIII will use local exhaust ventilation specially at sortation area on sieve machine. To maintain the quality of the black tea orthodox, all machine must be scheduled for maintenance every once a month and takes time 2 hours in workhours, with additional local exhaust ventilation, it will increase time for maintenance process, if maintenance takes time more than 2 hours it will caused production process delayed. To support maintenance process in PT Perkebunan Nusantara VIII Ciater, designing local exhaust ventilation using design for assembly approach with Boothroyd and Dewhurst method, design for assembly approach is choosen to simplify maintenance process which required assembly process. There are 2 LEV designs for this research. Design 1 with 94 components, assembly time 647.88 seconds and assembly efficiency level 23.62%. Design 2 with 82 components, assembly time 567.84 seconds and assembly efficiency level 24.83%. Design 2 is choosen for this research based on DFA goals, minimum total part that use, optimization assembly time, and assembly efficiency level.
Ferrando, Carlos; Suárez-Sipmann, Fernando; Gutierrez, Andrea; Tusman, Gerardo; Carbonell, Jose; García, Marisa; Piqueras, Laura; Compañ, Desamparados; Flores, Susanie; Soro, Marina; Llombart, Alicia; Belda, Francisco Javier
2015-01-13
The stress index (SI), a parameter derived from the shape of the pressure-time curve, can identify injurious mechanical ventilation. We tested the hypothesis that adjusting tidal volume (VT) to a non-injurious SI in an open lung condition avoids hypoventilation while preventing overdistension in an experimental model of combined lung injury and low chest-wall compliance (Ccw). Lung injury was induced by repeated lung lavages using warm saline solution, and Ccw was reduced by controlled intra-abdominal air-insufflation in 22 anesthetized, paralyzed and mechanically ventilated pigs. After injury animals were recruited and submitted to a positive end-expiratory pressure (PEEP) titration trial to find the PEEP level resulting in maximum compliance. During a subsequent four hours of mechanical ventilation, VT was adjusted to keep a plateau pressure (Pplat) of 30 cmH2O (Pplat-group, n = 11) or to a SI between 0.95 and 1.05 (SI-group, n = 11). Respiratory rate was adjusted to maintain a 'normal' PaCO2 (35 to 65 mmHg). SI, lung mechanics, arterial-blood gases haemodynamics pro-inflammatory cytokines and histopathology were analyzed. In addition Computed Tomography (CT) data were acquired at end expiration and end inspiration in six animals. PaCO2 was significantly higher in the Pplat-group (82 versus 53 mmHg, P = 0.01), with a resulting lower pH (7.19 versus 7.34, P = 0.01). We observed significant differences in VT (7.3 versus 5.4 mlKg(-1), P = 0.002) and Pplat values (30 versus 35 cmH2O, P = 0.001) between the Pplat-group and SI-group respectively. SI (1.03 versus 0.99, P = 0.42) and end-inspiratory transpulmonary pressure (PTP) (17 versus 18 cmH2O, P = 0.42) were similar in the Pplat- and SI-groups respectively, without differences in overinflated lung areas at end- inspiration in both groups. Cytokines and histopathology showed no differences. Setting tidal volume to a non-injurious stress index in an open lung condition improves alveolar ventilation and prevents overdistension without increasing lung injury. This is in comparison with limited Pplat protective ventilation in a model of lung injury with low chest-wall compliance.
24 CFR 3280.309 - Health Notice on formaldehyde emissions.
Code of Federal Regulations, 2011 CFR
2011-04-01
... efficiency standards may allow formaldehyde and other contaminants to accumulate in the indoor air. Additional ventilation to dilute the indoor air may be obtained from a passive or mechanical ventilation... offered with this home. High indoor temperatures and humidity raise formaldehyde levels. When a home is to...
An exposure chamber, the "clambox", was developed to measure ventilation rate, sediment processing rate, and efficiency of pollutant uptake byMacoma nasuta Conrad, a surface surface deposit-feeding clams. Clams, collected from Yaquina, Bay, Oregon, USA, were cemented into a hole ...
Marjanovic, Nicolas; Le Floch, Soizig; Jaffrelot, Morgan; L'Her, Erwan
2014-05-01
In the absence of endotracheal intubation, the manual bag-valve-mask (BVM) is the most frequently used ventilation technique during resuscitation. The efficiency of other devices has been poorly studied. The bench-test study described here was designed to evaluate the effectiveness of an automatic, manually triggered system, and to compare it with manual BVM ventilation. A respiratory system bench model was assembled using a lung simulator connected to a manikin to simulate a patient with unprotected airways. Fifty health-care providers from different professional groups (emergency physicians, residents, advanced paramedics, nurses, and paramedics; n = 10 per group) evaluated manual BVM ventilation, and compared it with an automatic manually triggered device (EasyCPR). Three pathological situations were simulated (restrictive, obstructive, normal). Standard ventilation parameters were recorded; the ergonomics of the system were assessed by the health-care professionals using a standard numerical scale once the recordings were completed. The tidal volume fell within the standard range (400-600 mL) for 25.6% of breaths (0.6-45 breaths) using manual BVM ventilation, and for 28.6% of breaths (0.3-80 breaths) using the automatic manually triggered device (EasyCPR) (P < .0002). Peak inspiratory airway pressure was lower using the automatic manually triggered device (EasyCPR) (10.6 ± 5 vs 15.9 ± 10 cm H2O, P < .001). The ventilation rate fell consistently within the guidelines, in the case of the automatic manually triggered device (EasyCPR) only (10.3 ± 2 vs 17.6 ± 6, P < .001). Significant pulmonary overdistention was observed when using the manual BVM device during the normal and obstructive sequences. The nurses and paramedics considered the ergonomics of the automatic manually triggered device (EasyCPR) to be better than those of the manual device. The use of an automatic manually triggered device may improve ventilation efficiency and decrease the risk of pulmonary overdistention, while decreasing the ventilation rate.
Javanese House’s Roof (Joglo) with the Opening as a Cooling Energy Provider
NASA Astrophysics Data System (ADS)
Pranoto S, M.
2018-01-01
Natural ventilation and air movement could be considered under the heading structural controls as it does not rely on any form of energy supply or mechanical installation but due to its importance for human comfort, it deserves a separate section. Air infiltration can destroy the performance of ventilation systems. Good ventilation design combined with optimum air tightness is needed to ensure energy efficient ventilation. Ultimately, ventilation needs depend on occupancy pattern and building use. A full cost and energy analysis is therefore needed to select an optimum ventilation strategy.The contains of paper is about the element of Javanese house (the roof) as the element of natural ventilation and a cooling energy provider. In this research, The Computational Fluid Dynamics Program, is used to draw and analysis. That tool can be track the pattern and the direction of movement of air also the air velocity in the object of ventilation of the roof Javanese house based. Finally, the ventilation of the roof of this Javanese house can add the velocity of air at indoor, average 0.4 m/s and give the effect of cooling, average 0.7°C.
Zhang, Xiaolei; Wang, Chen; Dai, Huaping; Lin, Yingxiang; Zhang, Jun
2008-09-01
Recent studies have shown that polymorphisms of the angiotensin-converting enzyme (ACE) gene are closely associated with pulmonary disorders. The ACE gene is involved in the regulation of inflammatory reactions to lung injury, respiratory drive, erythropoiesis and tissue oxygenation. The hypothesis for this study was that the ACE gene may be associated with the ventilatory response to exercise and the aerobic work efficiency of skeletal muscle in patients with COPD. Sixty-one Chinese Han COPD patients and 57 healthy control subjects performed incremental cardiopulmonary exercise testing on a cycle ergometer. ACE genotypes were determined using PCR amplification. Resting lung function and blood gas index were not significantly different among the three ACE genotype COPD groups. Similarly, there were no significant differences in AT, maximal O(2) uptake, maximal O(2) pulse, maximal dyspnoea index, ventilatory response (DeltaVE/DeltaVCO(2)), O(2) cost of ventilation (VO(2)/W/VE), end-tidal partial pressure of carbon dioxide at maximal exercise and maximal SaO(2) among the three ACE genotype COPD patients. Maximal work load and aerobic work efficiency were higher in the COPD group with the II genotype than in those with the ID or DD genotype. There were no significant differences in resting lung function and cardiopulmonary exercise testing parameters among the three ACE genotype control groups. The ACE gene may be involved in the regulation of skeletal muscle aerobic work efficiency, but is not associated with the ventilatory responses to exercise in COPD patients.
2016-08-02
at mechanical ventilation of a severely exposed casualty until atropine takes effect . Administering supplemental oxygen as available. Chapter 3 3-10...Scavengers; hydroxocobalamin, and dicobalt edetate (2) Provision of S-Groups, thiosulfate (3) Assisted ventilation (4) Oxygen cyanogen... temperature index for light work. Refer to table 1-3 on page 1-12 for work and rest cycles and also water consumption chart. Chapter 1 1-12 ATP 4
Lakshminrusimha, Satyan; Mathew, Bobby; Nair, Jayasree; Gugino, Sylvia F.; Koenigsknecht, Carmon; Rawat, Munmun; Nielsen, Lori; Swartz, Daniel D.
2014-01-01
Background Current neonatal resuscitation guidelines recommend tracheal suctioning of non-vigorous neonates born through meconium stained amniotic fluid. Methods We evaluated the effect of tracheal suctioning at birth in 29 lambs with asphyxia induced by cord occlusion and meconium aspiration during gasping. Results Tracheal suctioning at birth (n=15) decreased amount of meconium in distal airways (53±29 particles/mm2 lung area) compared to no-suction (499±109 particles/mm2, n=14, p<0.001). Three lambs in the suction group had cardiac arrest during suctioning requiring chest compressions and epinephrine. Onset of ventilation was delayed in the suction group (146±11 vs. 47±3 sec in no-suction group, p=0.005). There was no difference in pulmonary blood flow, carotid blood flow, pulmonary or systemic blood pressure between the two groups. Left atrial pressure was significantly higher in the suction group. Tracheal suctioning resulted in higher PaO2/FiO2 levels (122±21 vs. 78±10 mmHg) and ventilator efficiency index (0.3±0.05 vs.0.16±0.03). Two lambs in the no-suction group required inhaled NO. Lung 3-nitrotyrosine levels were higher in the suction group (0.65±0.03 ng/μg protein) compared to the no-suction group (0.47 ± 0.06). Conclusion Tracheal suctioning improves oxygenation and ventilation. Suctioning does not improve pulmonary/systemic hemodynamics or oxidative stress in an ovine model of acute meconium aspiration with asphyxia. PMID:25406897
Evaluation of microbiological air quality and of microclimate in university classrooms.
Grisoli, Pietro; Rodolfi, Marinella; Chiara, Tiziana; Zonta, Laura Attinia; Dacarro, Cesare
2012-07-01
The proliferation of air-diffused microorganisms inside public buildings such as schools, hospitals, and universities, is often indicated as a possible health risk. In this research, we have illustrated the results of an investigation realized to determine the health of the air in some university classrooms, both from a microbiological and a microclimatic viewpoint, during the normal didactic activity of direct lessons. The results obtained have been expressed by means of contamination indices, already used in previous works. Very little contamination was recorded in the different phases of air treatment, which underlines the efficiency of the system and of the maintenance protocols. The Global Index of Microbial Contamination (GIMC per cubic meter) showed a value greater than the mean during the heating period (290), while the highest values (95th percentile 1,138.45) were recorded in the period using air conditioning. The index of mesophilic bacterial contamination, though it did not show any significant differences in the various modes of air treatment, showed a mean value (1.34) and the 95th percentile value (4.14), which was greater in the air-conditioning phase. Finally, the mean value of the amplification index underlined a decrease in the microbial contamination in comparison to the outside, while showing situations of increased microbial amplification during the period of simple ventilation (95th percentile 4.27). The 95th percentile values found for GICM in the three sampling periods, however, permitted us to identify the value of GIMC per cubic meter equal to 1,000 as a guide to provide a means of self-monitoring the quality of the air inside the classrooms. From a microclimatic viewpoint, two periods of the year manifested discomfort situations: during the heating phase (winter) and during the simple ventilation phase (spring). The results obtained indicate, therefore, a need to intervene on the environmental parameters, not being able, in this particular case, to intervene on other aspects that influence the microclimate.
Tunnel Ventilation Control Using Reinforcement Learning Methodology
NASA Astrophysics Data System (ADS)
Chu, Baeksuk; Kim, Dongnam; Hong, Daehie; Park, Jooyoung; Chung, Jin Taek; Kim, Tae-Hyung
The main purpose of tunnel ventilation system is to maintain CO pollutant concentration and VI (visibility index) under an adequate level to provide drivers with comfortable and safe driving environment. Moreover, it is necessary to minimize power consumption used to operate ventilation system. To achieve the objectives, the control algorithm used in this research is reinforcement learning (RL) method. RL is a goal-directed learning of a mapping from situations to actions without relying on exemplary supervision or complete models of the environment. The goal of RL is to maximize a reward which is an evaluative feedback from the environment. In the process of constructing the reward of the tunnel ventilation system, two objectives listed above are included, that is, maintaining an adequate level of pollutants and minimizing power consumption. RL algorithm based on actor-critic architecture and gradient-following algorithm is adopted to the tunnel ventilation system. The simulations results performed with real data collected from existing tunnel ventilation system and real experimental verification are provided in this paper. It is confirmed that with the suggested controller, the pollutant level inside the tunnel was well maintained under allowable limit and the performance of energy consumption was improved compared to conventional control scheme.
Noizet, Odile; Leclerc, Francis; Sadik, Ahmed; Grandbastien, Bruno; Riou, Yvon; Dorkenoo, Aimée; Fourier, Catherine; Cremer, Robin; Leteurtre, Stephane
2005-01-01
Introduction We conducted the present study to determine whether a combination of the mechanical ventilation weaning predictors proposed by the collective Task Force of the American College of Chest Physicians (TF) and weaning endurance indices enhance prediction of weaning success. Method Conducted in a tertiary paediatric intensive care unit at a university hospital, this prospective study included 54 children receiving mechanical ventilation (≥6 hours) who underwent 57 episodes of weaning. We calculated the indices proposed by the TF (spontaneous respiratory rate, paediatric rapid shallow breathing, rapid shallow breathing occlusion pressure [ROP] and maximal inspiratory pressure during an occlusion test [Pimax]) and weaning endurance indices (pressure-time index, tension-time index obtained from P0.1 [TTI1] and from airway pressure [TTI2]) during spontaneous breathing. Performances of each TF index and combinations of them were calculated, and the best single index and combination were identified. Weaning endurance parameters (TTI1 and TTI2) were calculated and the best index was determined using a logistic regression model. Regression coefficients were estimated using the maximum likelihood ratio (LR) method. Hosmer–Lemeshow test was used to estimate goodness-of-fit of the model. An equation was constructed to predict weaning success. Finally, we calculated the performances of combinations of best TF indices and best endurance index. Results The best single TF index was ROP, the best TF combination was represented by the expression (0.66 × ROP) + (0.34 × Pimax), and the best endurance index was the TTI2, although their performance was poor. The best model resulting from the combination of these indices was defined by the following expression: (0.6 × ROP) – (0.1 × Pimax) + (0.5 × TTI2). This integrated index was a good weaning predictor (P < 0.01), with a LR+ of 6.4 and LR+/LR- ratio of 12.5. However, at a threshold value <1.3 it was only predictive of weaning success (LR- = 0.5). Conclusion The proposed combined index, incorporating endurance, was of modest value in predicting weaning outcome. This is the first report of the value of endurance parameters in predicting weaning success in children. Currently, clinical judgement associated with spontaneous breathing trials apparently remain superior. PMID:16356229
Modes of mechanical ventilation for the operating room.
Ball, Lorenzo; Dameri, Maddalena; Pelosi, Paolo
2015-09-01
Most patients undergoing surgical procedures need to be mechanically ventilated, because of the impact of several drugs administered at induction and during maintenance of general anaesthesia on respiratory function. Optimization of intraoperative mechanical ventilation can reduce the incidence of post-operative pulmonary complications and improve the patient's outcome. Preoxygenation at induction of general anaesthesia prolongs the time window for safe intubation, reducing the risk of hypoxia and overweighs the potential risk of reabsorption atelectasis. Non-invasive positive pressure ventilation delivered through different interfaces should be considered at the induction of anaesthesia morbidly obese patients. Anaesthesia ventilators are becoming increasingly sophisticated, integrating many functions that were once exclusive to intensive care. Modern anaesthesia machines provide high performances in delivering the desired volumes and pressures accurately and precisely, including assisted ventilation modes. Therefore, the physicians should be familiar with the potential and pitfalls of the most commonly used intraoperative ventilation modes: volume-controlled, pressure-controlled, dual-controlled and assisted ventilation. Although there is no clear evidence to support the advantage of any one of these ventilation modes over the others, protective mechanical ventilation with low tidal volume and low levels of positive end-expiratory pressure (PEEP) should be considered in patients undergoing surgery. The target tidal volume should be calculated based on the predicted or ideal body weight rather than on the actual body weight. To optimize ventilation monitoring, anaesthesia machines should include end-inspiratory and end-expiratory pause as well as flow-volume loop curves. The routine administration of high PEEP levels should be avoided, as this may lead to haemodynamic impairment and fluid overload. Higher PEEP might be considered during surgery longer than 3 h, laparoscopy in the Trendelenburg position and in patients with body mass index >35 kg/m(2). Large randomized trials are warranted to identify subgroups of patients and the type of surgery that can potentially benefit from specific ventilation modes or ventilation settings. Copyright © 2015 Elsevier Ltd. All rights reserved.
Temperature of gas delivered from ventilators.
Chikata, Yusuke; Onodera, Mutsuo; Imanaka, Hideaki; Nishimura, Masaji
2013-01-01
Although heated humidifiers (HHs) are the most efficient humidifying device for mechanical ventilation, some HHs do not provide sufficient humidification when the inlet temperature to the water chamber is high. Because portable and home-care ventilators use turbines, blowers, pistons, or compressors to inhale in ambient air, they may have higher gas temperature than ventilators with piping systems. We carried out a bench study to investigate the temperature of gas delivered from portable and home-care ventilators, including the effects of distance from ventilator outlet, fraction of inspiratory oxygen (FIO2), and minute volume (MV). We evaluated five ventilators equipped with turbine, blower, piston, or compressor system. Ambient air temperature was adjusted to 24°C ± 0.5°C, and ventilation was set at FIO2 0.21, 0.6, and 1.0, at MV 5 and 10 L/min. We analyzed gas temperature at 0, 40, 80, and 120 cm from ventilator outlet and altered ventilator settings. While temperature varied according to ventilators, the outlet gas temperature of ventilators became stable after, at the most, 5 h. Gas temperature was 34.3°C ± 3.9°C at the ventilator outlet, 29.5°C ± 2.2°C after 40 cm, 25.4°C ± 1.2°C after 80 cm and 25.1°C ± 1.2°C after 120 cm (P < 0.01). FIO2 and MV did not affect gas temperature. Gas delivered from portable and home-care ventilator was not too hot to induce heated humidifier malfunctioning. Gas soon declined when passing through the limb.
Bianchi, Biagio; Giametta, Ferruccio; La Fianza, Giovanna; Gentile, Andrea; Catalano, Pasquale
2015-01-01
The environment in the broiler house is a combination of physical and biological factors generating a complex dynamic system of interactions between birds, husbandry system, light, temperature, and the aerial environment. Ventilation plays a key role in this scenario. It is pivotal to remove carbon dioxide and water vapor from the air of the hen house. Adequate ventilation rates provide the most effective method of controlling temperature within the hen house. They allow for controlling the relative humidity and can play a key role in alleviating the negative effects of high stocking density and of wet litter. In the present study the results of experimental tests performed in a breeding broiler farm are shown. In particular the efficiency of a semi transversal ventilation system was studied against the use of a pure transversal one. In order to verify the efficiency of the systems, fluid dynamic simulations were carried out using the software Comsol multiphysics. The results of this study show that a correct architectural and structural design of the building must be supported by a design of the ventilation system able to maintain the environmental parameters within the limits of the thermo‑neutral and welfare conditions and to achieve the highest levels of productivity.
Effectiveness of in-room air filtration and dilution ventilation for tuberculosis infection control.
Miller-Leiden, S; Lobascio, C; Nazaroff, W W; Macher, J M
1996-09-01
Tuberculosis (TB) is a public health problem that may pose substantial risks to health care workers and others. TB infection occurs by inhalation of airborne bacteria emitted by persons with active disease. We experimentally evaluated the effectiveness of in-room air filtration systems, specifically portable air filters (PAFs) and ceiling-mounted air filters (CMAFs), in conjunction with dilution ventilation, for controlling TB exposure in high-risk settings. For each experiment, a test aerosol was continuously generated and released into a full-sized room. With the in-room air filter and room ventilation system operating, time-averaged airborne particle concentrations were measured at several points. The effectiveness of in-room air filtration plus ventilation was determined by comparing particle concentrations with and without device operation. The four PAFs and three CMAFs we evaluated reduced room-average particle concentrations, typically by 30% to 90%, relative to a baseline scenario with two air-changes per hour of ventilation (outside air) only. Increasing the rate of air flow recirculating through the filter and/or air flow from the ventilation did not always increase effectiveness. Concentrations were generally higher near the emission source than elsewhere in the room. Both the air flow configuration of the filter and its placement within the room were important, influencing room air flow patterns and the spatial distribution of concentrations. Air filters containing efficient, but non-high efficiency particulate air (HEPA) filter media were as effective as air filters containing HEPA filter media.
Effectiveness of In-Room Air Filtration and Dilution Ventilation for Tuberculosis Infection Control.
Miller-Leiden, S; Lohascio, C; Nazaroff, W W; Macher, J M
1996-09-01
Tuberculosis (TB) is a public health problem that may pose substantial risks to health care workers and others. TB infection occurs by inhalation of airborne bacteria emitted by persons with active disease. We experimentally evaluated the effectiveness of in-room air filtration systems, specifically portable air filters (PAFs) and ceiling-mounted air filters (CMAFs), in conjunction with dilution ventilation, for controlling TB exposure in high-risk settings. For each experiment, a test aerosol was continuously generated and released into a full-sized room. With the in-room air filter and room ventilation system operating, time-averaged airborne particle concentrations were measured at several points. The effectiveness of in-room air filtration plus ventilation was determined by comparing particle concentrations with and without device operation. The four PAFs and three CMAFs we evaluated reduced room-average particle concentrations, typically by 30% to 90%, relative to a baseline scenario with two air-changes per hour of ventilation (outside air) only. Increasing the rate of air flow recirculating through the filter and/or air flow from the ventilation did not always increase effectiveness. Concentrations were generally higher near the emission source than elsewhere in the room. Both the air flow configuration of the filter and its placement within the room were important, influencing room air flow patterns and the spatial distribution of concentrations. Air filters containing efficient, but non-high efficiency particulate air (HEPA) filter media were as effective as air filters containing HEPA filter media.
Evaluation of the Ventilated Flight Suit for OV-1 (Mohawk) Crews.
the ’ greenhouse effect ’ increases the temperature in the cockpit to approximately 100F. These temperatures create undesirable operating conditions and decrease the overall crew efficiency. The ventilated flight suit system was evaluated by means of questionnaires and interviews of the commanders, aviators, and maintenance personnel to determine its operational
Heating, Ventilation, Air Conditioning. Resource Manual for Custodial Training Course #3.
ERIC Educational Resources Information Center
Florida State Dept. of Education, Tallahassee. School Plant Management Section.
Intended as a manual to provide school custodians with some understanding of basic functions of heating, ventilating, and air conditioning equipment for safe, efficient operation. Contains general rules and specifications for providing custodians with a more complete awareness of their equipment and the field of "Climate Control" within the…
Barry, Rachel A; Fink, Daniel S; Pourciau, Dusty Cole; Hayley, Kasey; Lanius, Rachael; Hayley, Schuylor; Sims, Eddy; McWhorter, Andrew J
2017-09-01
Objective Jet ventilation has been used for >30 years as an anesthetic modality for laryngotracheal surgery. Concerns exist over increased risk with elevated body mass index (BMI). We reviewed our experience using jet ventilation for laryngotracheal stenosis to assess for complication rates with substratification by BMI. Study Design Case series with chart review. Setting Tertiary care center. Subjects and Methods A total of 126 procedures with jet ventilation were identified from October 2006 to December 2014. Complications were recorded, including intubation, unplanned admission, readmission, dysphonia, oral trauma, pneumothorax, pneumomediastinum, and tracheostomy. Lowest intraoperative oxygen saturation and maximum end-tidal CO 2 (ETCO 2 ) levels were recorded. Results Among 126 patients, 43, 77, and 6 had BMIs of <25, 25-35, and 36-45, respectively. In the BMI <25 group, there was 1 unplanned intubation. Mean maximum ETCO 2 was 36.51 with no hypoxemia observed. In the BMI 25-35 group, 2 patients required intubation, and 1 sustained minor oral trauma. The mean maximum ETCO 2 was 38.85, with 4 patients having oxygen saturation <90%. In the BMI 36-45 group, 2 patients required intubation. The mean maximum ETCO 2 was 41 with no hypoxemia observed. BMI and length of stenosis were statistically significant variables associated with incidence of intraoperative intubation. Conclusion Increased BMI was associated with an increase in highest ETCO 2 intraoperatively. However, this was not associated with an increase in major complications. Jet ventilation was performed without significant adverse events in this sample, and it is a viable option if used with an experienced team in the management of laryngotracheal stenosis.
Energy efficiency buildings program
NASA Astrophysics Data System (ADS)
1981-05-01
Progress is reported in developing techniques for auditing the energy performance of buildings. The ventilation of buildings and indoor air quality is discussed from the viewpoint of (1) combustion generated pollutants; (2) organic contaminants; (3) radon emanation, measurements, and control; (4) strategies for the field monitoring of indoor air quality; and (5) mechanical ventilation systems using air-to-air heat exchanges. The development of energy efficient windows to provide optimum daylight with minimal thermal losses in cold weather and minimum thermal gain in hot weather is considered as well as the production of high frequency solid state ballasts for fluorescent lights to provide more efficient lighting at a 25% savings over conventional core ballasts. Data compilation, analysis, and demonstration activities are summarized.
Fanfulla, Francesco; Ceriana, Piero; D'Artavilla Lupo, Nadia; Trentin, Rossella; Frigerio, Francesco; Nava, Stefano
2011-01-01
Background: Severe sleep disruption is a well-documented problem in mechanically ventilated, critically ill patients during their time in the intensive care unit (ICU), but little attention has been paid to the period when these patients become clinically stable and are transferred to a step-down unit (SDU). We monitored the 24-h sleep pattern in 2 groups of patients, one on mechanical ventilation and the other breathing spontaneously, admitted to our SDU to assess the presence of sleep abnormalities and their association with mechanical ventilation. Methods: Twenty-two patients admitted to an SDU underwent 24-h polysomnography with monitoring of noise and light. Results: One patient did not complete the study. At night, 10 patients showed reduced sleep efficiency, 6 had reduced percentage of REM sleep, and 3 had reduced percentage of slow wave sleep (SWS). Sleep amount and quality did not differ between patients breathing spontaneously and those on mechanical ventilation. Clinical severity (SAPSII score) was significantly correlated with daytime total sleep time and efficiency (r = 0.51 and 0.5, P < 0.05, respectively); higher pH was correlated with reduced sleep quantity and quality; and higher PaO2 was correlated with increased SWS (r = 0.49; P = 0.02). Conclusions: Patients admitted to an SDU after discharge from an ICU still have a wide range of sleep abnormalities. These abnormalities are mainly associated with a high severity score and alkalosis. Mechanical ventilation does not appear to be a primary cause of sleep impairment. Citation: Fanfulla F; Ceriana P; Lupo ND; Trentin R; Frigerio F; Nava S. Sleep disturbances in patients admitted to a step-down unit after ICU discharge: the role of mechanical ventilation. SLEEP 2011;34(3):355-362. PMID:21358853
Kasenda, Benjamin; Sauerbrei, Willi; Royston, Patrick; Mercat, Alain; Slutsky, Arthur S; Cook, Deborah; Guyatt, Gordon H; Brochard, Laurent; Richard, Jean-Christophe M; Stewart, Thomas E; Meade, Maureen; Briel, Matthias
2016-09-08
A recent individual patient data (IPD) meta-analysis suggested that patients with moderate or severe acute respiratory distress syndrome (ARDS) benefit from higher positive end-expiratory pressure (PEEP) ventilation strategies. However, thresholds for continuous variables (eg, hypoxaemia) are often arbitrary and linearity assumptions in regression approaches may not hold; the multivariable fractional polynomial interaction (MFPI) approach can address both problems. The objective of this study was to apply the MFPI approach to investigate interactions between four continuous patient baseline variables and higher versus lower PEEP on clinical outcomes. Pooled data from three randomised trials in intensive care identified by a systematic review. 2299 patients with acute lung injury requiring mechanical ventilation. Higher (N=1136) versus lower PEEP (N=1163) ventilation strategy. Prespecified outcomes included mortality, time to death and time-to-unassisted breathing. We examined the following continuous baseline characteristics as potential effect modifiers using MFPI: PaO2/FiO2 (arterial partial oxygen pressure/ fraction of inspired oxygen), oxygenation index, respiratory system compliance (tidal volume/(inspiratory plateau pressure-PEEP)) and body mass index (BMI). We found that for patients with PaO2/FiO2 below 150 mm Hg, but above 100 mm Hg or an oxygenation index above 12 (moderate ARDS), higher PEEP reduces hospital mortality, but the beneficial effect appears to level off for patients with very severe ARDS. Patients with mild ARDS (PaO2/FiO2 above 200 mm Hg or an oxygenation index below 10) do not seem to benefit from higher PEEP and might even be harmed. For patients with a respiratory system compliance above 40 mL/cm H2O or patients with a BMI above 35 kg/m(2), we found a trend towards reduced mortality with higher PEEP, but there is very weak statistical confidence in these findings. MFPI analyses suggest a nonlinear effect modification of higher PEEP ventilation by PaO2/FiO2 and oxygenation index with reduced mortality for some patients suffering from moderate ARDS. CRD42012003129. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Nasal mask ventilation is better than face mask ventilation in edentulous patients.
Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil
2016-01-01
Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients.
A prototype of volume-controlled tidal liquid ventilator using independent piston pumps.
Robert, Raymond; Micheau, Philippe; Cyr, Stéphane; Lesur, Olivier; Praud, Jean-Paul; Walti, Hervé
2006-01-01
Liquid ventilation using perfluorochemicals (PFC) offers clear theoretical advantages over gas ventilation, such as decreased lung damage, recruitment of collapsed lung regions, and lavage of inflammatory debris. We present a total liquid ventilator designed to ventilate patients with completely filled lungs with a tidal volume of PFC liquid. The two independent piston pumps are volume controlled and pressure limited. Measurable pumping errors are corrected by a programmed supervisor module, which modifies the inserted or withdrawn volume. Pump independence also allows easy functional residual capacity modifications during ventilation. The bubble gas exchanger is divided into two sections such that the PFC exiting the lungs is not in contact with the PFC entering the lungs. The heating system is incorporated into the metallic base of the gas exchanger, and a heat-sink-type condenser is placed on top of the exchanger to retrieve PFC vapors. The prototype was tested on 5 healthy term newborn lambs (<5 days old). The results demonstrate the efficiency and safety of the prototype in maintaining adequate gas exchange, normal acido-basis equilibrium, and cardiovascular stability during a short, 2-hour total liquid ventilator. Airway pressure, lung volume, and ventilation scheme were maintained in the targeted range.
Zhao, Zhanqi; Pulletz, Sven; Frerichs, Inéz; Müller-Lisse, Ullrich; Möller, Knut
2014-02-06
The electrical impedance tomography (EIT)-based global inhomogeneity (GI) index was introduced to quantify tidal volume distribution within the lung. Up to now, the GI index was evaluated for plausibility but the analysis of how it is influenced by various physiological factors is still missing. The aim of our study was to evaluate the influence of proportion of open lung regions measured by EIT on the GI index. A constant low-flow inflation maneuver was performed in 18 acute respiratory distress syndrome (ARDS) patients (58 ± 14 years, mean age ± SD) and 8 lung-healthy patients (41 ± 12 years) under controlled mechanical ventilation. EIT raw data were acquired at 25 scans/s and reconstructed offline. Recruited lung regions were identified as those image pixels of the lung regions within the EIT scans where local impedance amplitudes exceeded 10% of the maximum amplitude during the maneuver. A series of GI indices was calculated during mechanical lung inflation, based on the differential images obtained between different time points. Respiratory system elastance (Ers) values were calculated at 10 lung volume levels during low-flow maneuver. The GI index decreased during low-flow inflation, while the percentage of open lung regions increased. The values correlated highly in both ARDS (r2 = 0.88 ± 0.08, p < 0.01) and lung-healthy patients (r2 = 0.92 ± 0.05, p < 0.01). Ers and GI index were also significantly correlated in 16 out of 18 ARDS (r2 = 0.84 ± 0.13, p < 0.01) and in 6 out of 8 lung-healthy patients (r2 = 0.84 ± 0.07, p < 0.01). Significant differences were found in GI values between two groups (0.52 ± 0.21 for ARDS and 0.41 ± 0.04 for lung-healthy patients, p < 0.05) as well in Ers values (0.017 ± 0.008 cmH2O/ml for ARDS and 0.009 ± 0.001 cmH2O/ml for lung-healthy patients, p < 0.01). We conclude that the GI index is a reliable measure of ventilation heterogeneity highly correlated with lung recruitability measured with EIT. The GI index may prove to be a useful EIT-based index to guide ventilation therapy.
Matsunami, Sayuri; Komasawa, Nobuyasu; Konishi, Yuki; Minami, Toshiaki
2017-11-01
We performed two prospective randomized crossover trials to evaluate the effect of head elevation or lateral head rotation to facemask ventilation volume. In the first trial, facemask ventilation was performed with a 12-cm high pillow (HP) and 4-cm low pillow (LP) in 20 female patients who were scheduled to undergo general anesthesia. In the second trial, facemask ventilation was performed with and without lateral head rotation in another 20 female patients. Ventilation volume was measured in a pressure-controlled ventilation (PCV) manner at 10, 15, and 20 cmH 2 O inspiratory pressures. In the first trial evaluating head elevation effect, facemask ventilation volume was significantly higher with a HP than with a LP at 15 and 20 cmH 2 O inspiratory pressure (15 cmH 2 O: HP median 540 [ IQR 480-605] mL, LP 460 [400-520] mL, P=0.006, 20 cmH 2 O: HP 705 [650-800] mL, LP 560 [520-677] mL, P<0.001). In the second trial, lateral head rotation did not significantly increase facemask ventilation volume at all inspiratory pressure. Head elevation increased facemask ventilation volume in normal airway patients, while lateral head rotation did not. Copyright © 2017 Elsevier Inc. All rights reserved.
do Vale, Jorge Marques; Silva, Eloísa; Pereira, Isabel Gil; Marques, Catarina; Sanchez-Serrano, Amparo; Torres, António Simões
2014-01-01
The Chiari malformation type I (CM-I) has been associated with sleep-disordered breathing, especially central sleep apnea syndrome. We report the case of a 44-year-old female with CM-I who was referred to our sleep laboratory for suspected sleep apnea. The patient had undergone decompressive surgery 3 years prior. An arterial blood gas analysis showed hypercapnia. Polysomnography showed a respiratory disturbance index of 108 events/h, and all were central apnea events. Treatment with adaptive servo-ventilation was initiated, and central apnea was resolved. This report demonstrates the efficacy of servo-ventilation in the treatment of central sleep apnea syndrome associated with alveolar hypoventilation in a CM-I patient with a history of decompressive surgery. PMID:25410846
Grigoliia, G N; Chokhonelidze, I K; Gvelesiani, L G; Sulakvelidze, K R; Tutberidze, K N
2007-01-01
The body oxygen consumption and the oxygen cost of breathing (which is the difference in oxygen consumption measured during controlled ventilation and again during spontaneous ventilation) were measured in 46 children with congenital heart diseases after open-heart surgery. There was a significant exponential correlation between the body oxygen consumption (ml/m(2)/min) and the oxygen cost of breathing as a percentage of total oxygen consumption during spontaneous ventilation and the duration of weaning in minutes (r=+0,882, p<0,02). Therefore, as the oxygen cost of breathing was correlated with the total weaning time, this may be a useful index on the weaning process (sensitivity 92%, specificity 85%).
Morisseau, K; Joubert, A; Le Coq, L; Andres, Y
2017-05-01
This study aimed to demonstrate that particles, especially those associated with fungi, could be released from fibrous filters used in the air-handling unit (AHU) of heating, ventilation and air-conditioning (HVAC) systems during ventilation restarts. Quantification of the water retention capacity and SEM pictures of the filters was used to show the potential for fungal proliferation in unused or preloaded filters. Five fibrous filters with various particle collection efficiencies were studied: classes G4, M5, M6, F7, and combined F7 according to European standard EN779:2012. Filters were clogged with micronized rice particles containing the fungus Penicillium chrysogenum and then incubated for three weeks at 25°C and 90% relative humidity. The results indicated that the five clogged tested filters had various fungal growth capacities depending on their water retention capacity. Preloaded filters were subjected to a simulated ventilation restart in a controlled filtration device to quantify that the fraction of particles released was around 1% for the G4, 0.1% for the M5 and the M6, and 0.001% for the F7 and the combined F7 filter. The results indicate that the likelihood of fungal particle release by low efficiency filters is significantly higher than by high efficiency filters. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Spengler, John D.; Harley, Amy E.; Stoddard, Anne; Yang, May; Alvarez-Reeves, Marty; Sorensen, Glorian
2014-01-01
Objectives. We explored prevalence and clustering of key environmental conditions in low-income housing and associations with self-reported health. Methods. The Health in Common Study, conducted between 2005 and 2009, recruited participants (n = 828) from 20 low-income housing developments in the Boston area. We interviewed 1 participant per household and conducted a brief inspection of the unit (apartment). We created binary indexes and a summed index for household exposures: mold, combustion by-products, secondhand smoke, chemicals, pests, and inadequate ventilation. We used multivariable logistic regression to examine the associations between each index and household characteristics and between each index and self-reported health. Results. Environmental problems were common; more than half of homes had 3 or more exposure-related problems (median summed index = 3). After adjustment for household-level demographics, we found clustering of problems in site (P < .01) for pests, combustion byproducts, mold, and ventilation. Higher summed index values were associated with higher adjusted odds of reporting fair–poor health (odds ratio = 2.7 for highest category; P < .008 for trend). Conclusions. We found evidence that indoor environmental conditions in multifamily housing cluster by site and that cumulative exposures may be associated with poor health. PMID:24028244
Corrà, Ugo; Giordano, Andrea; Mezzani, Alessandro; Gnemmi, Marco; Pistono, Massimo; Caruso, Roberto; Giannuzzi, Pantaleo
2012-02-01
The study aims were to validate the cardiopulmonary exercise testing (CPET) parameters recommended by the European Society of Cardiology 2008 Guidelines for risk assessment in heart failure (HF) (ESC-predictors) and to verify the predictive role of 11 supplementary CPET (S-predictors) parameters. We followed 749 HF patients for cardiovascular death and urgent heart transplantation for 3 years: 139 (19%) patients had cardiac events. ESC-predictors - peak oxygen consumption (VO(2)), slope of minute ventilation vs carbon dioxide production (VE/VCO(2)) and exertional oscillatory ventilation - were all related to outcome at univariate and multivariable analysis. The ESC/2008 prototype based on ESC-predictors presented a Harrell's C concordance index of 0.725, with a likely χ2 of 98.31. S-predictors - predicted peak VO(2), peak oxygen pulse, peak respiratory exchange ratio, peak circulatory power, peak VE/VCO(2), VE/VCO(2) slope normalized by peak VO(2), VO(2) efficiency slope, ventilatory anaerobic threshold detection, peak end-tidal CO(2) partial pressure, peak heart rate, and peak systolic arterial blood pressure (SBP) - were all linked to outcome at univariate analysis. When individually added to the ESC/2008 prototype, only peak SBP and peak O(2) pulse significantly improved the model discrimination ability: the ESC + peak SBP prototype had a Harrell's C index 0.750 and reached the highest likely χ2 (127.16, p < 0.0001). We evaluated the longest list of CPET prognostic parameters yet studied in HF: ESC-predictors were independent predictors of cardiovascular events, and the ESC prototype showed a convincing predictive capacity, whereas none of 11 S-predictors enhanced the prognostic performance, except peak SBP.
Emhofer, Waltraud; Lichtenegger, Klaus; Haslinger, Walter; Hofbauer, Hermann; Schmutzer-Roseneder, Irene; Aigenbauer, Stefan; Lienhard, Martin
2015-01-01
Wood pellets have been reported to emit toxic gaseous emissions during transport and storage. Carbon monoxide (CO) emission, due to the high toxicity of the gas and the possibility of it being present at high levels, is the most imminent threat to be considered before entering a pellet storage facility. For small-scale (<30 tons storage capacity) residential pellet storage facilities, ventilation, preferably natural ventilation utilizing already existing openings, has become the most favored solution to overcome the problem of high CO concentrations. However, there is little knowledge on the ventilation rates that can be reached and thus on the effectiveness of such measures. The aim of the study was to investigate ventilation rates for a specific small-scale pellet storage system depending on characteristic temperature differences. Furthermore, the influence of the implementation of a chimney and the influence of cross-ventilation on the ventilation rates were investigated. The air exchange rates observed in the experiments ranged between close to zero and up to 8 m(3) h(-1), depending largely on the existing temperature differences and the existence of cross-ventilation. The results demonstrate that implementing natural ventilation is a possible measure to enhance safety from CO emissions, but not one without limitations. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Cardiopulmonary function after pulmonary contusion and partial liquid ventilation.
Moomey, C B; Fabian, T C; Croce, M A; Melton, S M; Proctor, K G
1998-08-01
To compare the effects of mechanical ventilation with either positive end-expiratory pressure (PEEP) or partial liquid ventilation (PLV) on cardiopulmonary function after severe pulmonary contusion. Mongrel pigs (32 +/- 1 kg) were anesthetized, paralyzed, and mechanically ventilated (8-10 mL/kg tidal volume; 12 breaths/min; FiO2 = 0.5). Systemic hemodynamics and pulmonary function were measured for 7 hours after a captive bolt gun delivered a blunt injury to the right chest. After 5 hours, FiO2 was increased to 1.0 and either PEEP (n = 7) in titrated increments to 25 cm H2O or PLV with perflubron (LiquiVent, 30 mL/kg, endotracheal) and no PEEP (n = 7) was administered for 2 hours. Two control groups received injury without treatment (n = 6) or no injury with PLV (n = 3). Fluids were liberalized with PEEP versus PLV (27 +/- 3 vs. 18 +/- 2 mL.kg-1.h-1) to maintain cardiac filling pressures. Before treatment at 5 hours after injury, physiologic dead space fraction (30 +/- 4%), pulmonary vascular resistance (224 +/- 20% of baseline), and airway resistance (437 +/- 110% of baseline) were all increased (p < 0.05). In addition, PaO2/FiO2 had decreased to 112 +/- 18 mm Hg, compliance was depressed to 11 +/- 1 mL/cm H2O (36 +/- 3% of baseline), and shunt fraction was increased to 22 +/- 4% (all p < 0.05). Blood pressure and cardiac index remained stable relative to baseline, but stroke index and systemic oxygen delivery were depressed by 15 to 30% (both p < 0.05). After 2 hours of treatment with PEEP versus PLV, PO2/FiO2 was higher (427 +/- 20 vs. 263 +/- 37) and dead space ventilation was lower (4 +/- 3 vs. 28 +/- 7%) (both p < 0.05), whereas compliance tended to be higher (26 +/- 2 vs. 20 +/- 2) and shunt fraction tended to be lower (0 +/- 0 vs. 7 +/- 4). With PEEP versus PLV, however, cardiac index, stroke index, and systemic oxygen delivery were 30 to 60% lower (all p < 0.05). Furthermore, although contused lungs showed similar damage with either treatment, the secondary injury in the contralateral lung (as manifested by intra-alveolar hemorrhage) was more severe with PEEP than with PLV. Both PEEP and PLV improved pulmonary function after severe unilateral pulmonary contusion, but negative hemodynamic and histologic changes were associated with PEEP and not with PLV. These data suggest that PLV is a promising novel ventilatory strategy for unilateral pulmonary contusion that might ameliorate secondary injury in the contralateral uninjured lung.
Chen, Lu; Chen, Guang-Qiang; Shore, Kevin; Shklar, Orest; Martins, Concetta; Devenyi, Brian; Lindsay, Paul; McPhail, Heather; Lanys, Ashley; Soliman, Ibrahim; Tuma, Mazin; Kim, Michael; Porretta, Kerri; Greco, Pamela; Every, Hilary; Hayes, Chris; Baker, Andrew; Friedrich, Jan O; Brochard, Laurent
2017-04-04
Despite their potential interest for clinical management, measurements of respiratory mechanics in patients with acute respiratory distress syndrome (ARDS) are seldom performed in routine practice. We introduced a systematic assessment of respiratory mechanics in our clinical practice. After the first year of clinical use, we retrospectively assessed whether these measurements had any influence on clinical management and physiological parameters associated with clinical outcomes by comparing their value before and after performing the test. The respiratory mechanics assessment constituted a set of bedside measurements to determine passive lung and chest wall mechanics, response to positive end-expiratory pressure, and alveolar derecruitment. It was obtained early after ARDS diagnosis. The results were provided to the clinical team to be used at their own discretion. We compared ventilator settings and physiological variables before and after the test. The physiological endpoints were oxygenation index, dead space, and plateau and driving pressures. Sixty-one consecutive patients with ARDS were enrolled. Esophageal pressure was measured in 53 patients (86.9%). In 41 patients (67.2%), ventilator settings were changed after the measurements, often by reducing positive end-expiratory pressure or by switching pressure-targeted mode to volume-targeted mode. Following changes, the oxygenation index, airway plateau, and driving pressures were significantly improved, whereas the dead-space fraction remained unchanged. The oxygenation index continued to improve in the next 48 h. Implementing a systematic respiratory mechanics test leads to frequent individual adaptations of ventilator settings and allows improvement in oxygenation indexes and reduction of the risk of overdistention at the same time. The present study involves data from our ongoing registry for respiratory mechanics (ClinicalTrials.gov identifier: NCT02623192 . Registered 30 July 2015).
Ventilatory Patterning in a Mouse Model of Stroke
Koo, Brian B; Strohl, Kingman P; Gillombardo, Carl B; Jacono, Frank J
2010-01-01
Cheyne-Stokes respiration (CSR) is a breathing pattern characterized by waxing and waning of breath volume and frequency, and is often recognized following stroke, when causal pathways are often obscure. We used an animal model to address the hypothesis that cerebral infarction is a mechanism for producing breathing instability. Fourteen male A/J mice underwent either stroke (n=7) or sham (n=7) procedure. Ventilation was measured using whole body plethysmography. Respiratory rate (RR), tidal volume (VT) and minute ventilation (Ve) mean values and coefficient of variation were computed for ventilation and oscillatory behavior. In addition, the ventilatory data were computationally fit to models to quantify autocorrelation, mutual information, sample entropy and a nonlinear complexity index. At the same time post procedure, stroke when compared to sham animal breathing consisted of a lower RR and autocorrelation, higher coefficient of variation for VT and higher coefficient of variation for Ve. Mutual information and the nonlinear complexity index were higher in breathing following stroke which also demonstrated a waxing/waning pattern. The absence of stroke in the sham animals was verified anatomically. We conclude that ventilatory pattern following cerebral infarction demonstrated increased variability with increased nonlinear patterning and a waxing/waning pattern, consistent with CSR. PMID:20472101
Semiparametric Modeling of Daily Ammonia Levels in Naturally Ventilated Caged-Egg Facilities
Gutiérrez-Zapata, Diana María; Galeano-Vasco, Luis Fernando; Cerón-Muñoz, Mario Fernando
2016-01-01
Ammonia concentration (AMC) in poultry facilities varies depending on different environmental conditions and management; however, this is a relatively unexplored subject in Colombia (South America). The objective of this study was to model daily AMC variations in a naturally ventilated caged-egg facility using generalized additive models. Four sensor nodes were used to record AMC, temperature, relative humidity and wind speed on a daily basis, with 10 minute intervals for 12 weeks. The following variables were included in the model: Heat index, Wind, Hour, Location, Height of the sensor to the ground level, and Period of manure accumulation. All effects included in the model were highly significant (p<0.001). The AMC was higher during the night and early morning when the wind was not blowing (0.0 m/s) and the heat index was extreme. The average and maximum AMC were 5.94±3.83 and 31.70 ppm, respectively. Temperatures above 25°C and humidity greater than 80% increased AMC levels. In naturally ventilated caged-egg facilities the daily variations observed in AMC primarily depend on cyclic variations of the environmental conditions and are also affected by litter handling (i.e., removal of the bedding material). PMID:26812150
Energy-Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Withers, Jr., Charles R.
2016-12-01
In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split onmore » seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
2017-01-01
In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split onmore » seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.« less
Energy Efficiency in Libraries.
ERIC Educational Resources Information Center
Lewis, Eleanor J.; And Others
1993-01-01
Shows how libraries can save money and energy with energy-efficient technologies, improving maintenance, and encouraging staff efforts to conserve energy. Specific techniques such as life-cycle cost analysis and energy audits focusing on lighting, heating, ventilation, air conditioning, and water efficiency are described. Funding options and…
Contributions of tidal lung inflation to human R-R interval and arterial pressure fluctuations
NASA Technical Reports Server (NTRS)
Koh, J.; Brown, T. E.; Beightol, L. A.; Eckberg, D. L.
1998-01-01
We studied the effects of mechanical lung inflation on respiratory frequency R-R interval and arterial pressure fluctuations in nine healthy young adults undergoing elective orthopedic surgery. We conducted this research to define the contribution of pulmonary and thoracic stretch receptor input to respiratory sinus arrhythmia. We compared fast Fourier transform spectral power during three modes of ventilation: (1) spontaneous, frequency-controlled (0.25 Hz) breathing, (2) intermittent positive pressure ventilation (0.25 Hz, with a tidal volume of 8 ml/kg) and (3) high frequency jet ventilation (5.0 Hz, 2.5 kg/cm2), after sedation and vecuronium paralysis. Mean R-R intervals, arterial pressures and arterial blood gas levels were comparable during all three breathing conditions. Respiratory frequency systolic pressure spectral power was comparable during spontaneous breathing and conventional mechanical ventilation, but was significantly reduced during high frequency jet ventilation (P < 0.05). Respiratory frequency R-R interval spectral power (used as an index of respiratory sinus arrhythmia) declined dramatically with sedation and muscle paralysis (P < 0.05), but was greater during conventional mechanical, than high frequency jet ventilation (P < 0.05). These results suggest that although phasic inputs from pulmonary and thoracic stretch receptors make a statistically significant contribution to respiratory sinus arrhythmia, that contribution is small.
Sutton, P J; Perkins, C L; Giles, S P; McAuley, D F; Gao, F
2005-01-01
In this controlled, randomised cross-over trial on 26 intensive care patients, we compared the effects on haemodynamic and respiratory profiles of continuous positive airway pressure delivered through the Hamilton Galileo ventilator or a Drager CF 800 device. We also compared the nursing time saved using the two approaches when weaning patients from mechanical ventilation. We did not find significant differences in haemodynamics, respiratory rate, physiological dead space, oxygen saturation and carbon dioxide production between the continuous positive airway pressure generated by the Galileo and Drager machines. However, there was a 10-fold reduction in nursing time using the Galileo ventilator compared with the Drager generator. We conclude that continuous positive airway pressure delivered through the Galileo ventilator is as efficient as a Drager device but consumes less nursing time.
Lee, Ji Yeon
2016-10-01
Transmission of tuberculosis (TB) is a recognized risk to patients and healthcare workers in healthcare settings. The literature review suggests that implementation of combination control measures reduces the risk of TB transmission. Guidelines suggest a three-level hierarchy of controls including administrative, environmental, and respiratory protection. Among environmental controls, installation of ventilation systems is a priority because ventilation reduces the number of infectious particles in the air. Natural ventilation is cost-effective but depends on climatic conditions. Supplemented intervention such as air-cleaning methods including high efficiency particulate air filtration and ultraviolet germicidal irradiation should be considered in areas where adequate ventilation is difficult to achieve. Personal protective equipment including particulate respirators provides additional benefit when administrative and environmental controls cannot assure protection.
Nasal mask ventilation is better than face mask ventilation in edentulous patients
Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil
2016-01-01
Background and Aims: Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Material and Methods: Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. Results: A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Conclusion: Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients. PMID:27625477
Case, J.B.; Buesch, D.C.
2004-01-01
Predictions of waste canister and repository driftwall temperatures as functions of space and time are important to evaluate pre-closure performance of the proposed repository for spent nuclear fuel and high-level radioactive waste at Yucca Mountain, Nevada. Variations in the lithostratigraphic features in densely welded and crystallized rocks of the 12.8-million-year-old Topopah Spring Tuff, especially the porosity resulting from lithophysal cavities, affect thermal properties. A simulated emplacement drift is based on projecting lithophysal cavity porosity values 50 to 800 m from the Enhanced Characterization of the Repository Block cross drift. Lithophysal cavity porosity varies from 0.00 to 0.05 cm3/cm3 in the middle nonlithophysal zone and from 0.03 to 0.28 cm3/cm3 in the lower lithophysal zone. A ventilation model and computer program titled "Monte Carlo Simulation of Ventilation" (MCSIMVENT), which is based on a composite thermal-pulse calculation, simulates statistical variability and uncertainty of rock-mass thermal properties and ventilation performance along a simulated emplacement drift for a pre-closure period of 50 years. Although ventilation efficiency is relatively insensitive to thermal properties, variations in lithophysal porosity along the drift can result in a range of peak driftwall temperatures can range from 40 to 85??C for the preclosure period. Copyright ?? 2004 by ASME.
Rowan, Courtney M; Loomis, Ashley; McArthur, Jennifer; Smith, Lincoln S; Gertz, Shira J; Fitzgerald, Julie C; Nitu, Mara E; Moser, Elizabeth As; Hsing, Deyin D; Duncan, Christine N; Mahadeo, Kris M; Moffet, Jerelyn; Hall, Mark W; Pinos, Emily L; Tamburro, Robert F; Cheifetz, Ira M
2018-04-01
The effectiveness of high-frequency oscillatory ventilation (HFOV) in the pediatric hematopoietic cell transplant patient has not been established. We sought to identify current practice patterns of HFOV, investigate parameters during HFOV and their association with mortality, and compare the use of HFOV to conventional mechanical ventilation in severe pediatric ARDS. This is a retrospective analysis of a multi-center database of pediatric and young adult allogeneic hematopoietic cell transplant subjects requiring invasive mechanical ventilation for critical illness from 2009 through 2014. Twelve United States pediatric centers contributed data. Continuous variables were compared using a Wilcoxon rank-sum test or a Kruskal-Wallis analysis. For categorical variables, univariate analysis with logistic regression was performed. The database contains 222 patients, of which 85 subjects were managed with HFOV. Of this HFOV cohort, the overall pediatric ICU survival was 23.5% ( n = 20). HFOV survivors were transitioned to HFOV at a lower oxygenation index than nonsurvivors (25.6, interquartile range 21.1-36.8, vs 37.2, interquartile range 26.5-52.2, P = .046). Survivors were transitioned to HFOV earlier in the course of mechanical ventilation, (day 0 vs day 2, P = .002). No subject survived who was transitioned to HFOV after 1 week of invasive mechanical ventilation. We compared subjects with severe pediatric ARDS treated only with conventional mechanical ventilation versus early HFOV (within 2 d of invasive mechanical ventilation) versus late HFOV. There was a trend toward difference in survival (conventional mechanical ventilation 24%, early HFOV 30%, and late HFOV 9%, P = .08). In this large database of pediatric allogeneic hematopoietic cell transplant subjects who had acute respiratory failure requiring invasive mechanical ventilation for critical illness with severe pediatric ARDS, early use of HFOV was associated with improved survival compared to late implementation of HFOV, and the subjects had outcomes similar to those treated only with conventional mechanical ventilation. Copyright © 2018 by Daedalus Enterprises.
Nonrapid Eye Movement-Predominant Obstructive Sleep Apnea: Detection and Mechanism.
Yamauchi, Motoo; Fujita, Yukio; Kumamoto, Makiko; Yoshikawa, Masanori; Ohnishi, Yoshinobu; Nakano, Hiroshi; Strohl, Kingman P; Kimura, Hiroshi
2015-09-15
Obstructive sleep apnea (OSA) can be severe and present in higher numbers during rapid eye movement (REM) than nonrapid eye movement (NREM) sleep; however, OSA occurs in NREM sleep and can be predominant. In general, ventilation decreases an average 10% to 15% during transition from wakefulness to sleep, and there is variability in just how much ventilation decreases. As dynamic changes in ventilation contribute to irregular breathing and breathing during NREM sleep is mainly under chemical control, our hypothesis is that patients with a more pronounced reduction in ventilation during the transition from wakefulness to NREM sleep will have NREM- predominant rather than REM-predominant OSA. A retrospective analysis of 451 consecutive patients (apnea-hypopnea index [AHI] > 5) undergoing diagnostic polysomnography was performed, and breath-to-breath analysis of the respiratory cycle duration, tidal volume, and estimated minute ventilation before and after sleep onset were examined. Values were calculated using respiratory inductance plethysmography. The correlation between the percent change in estimated minute ventilation during wake-sleep transitions and the percentage of apnea-hypopneas in NREM sleep (%AHI in NREM; defined as (AHI-NREM) / [(AHI-NREM) + (AHI-REM)] × 100) was the primary outcome. The decrease in estimated minute ventilation during wake-sleep transitions was 15.0 ± 16.6% (mean ± standard deviation), due to a decrease in relative tidal volume. This decrease in estimated minute ventilation was significantly correlated with %AHI in NREM (r = -0.222, p < 0.01). A greater dynamic reduction in ventilation back and forth from wakefulness to sleep contributes to the NREM predominant OSA phenotype via induced ventilatory instability. © 2015 American Academy of Sleep Medicine.
Nardi, Julie; Leroux, Karl; Orlikowski, David; Prigent, Hélène
2015-01-01
Mouthpiece ventilation (MPV) allows patients with neuromuscular disease to receive daytime support from a portable ventilator, which they can disconnect at will, for example, for speaking, eating, swallowing, and coughing. However, MPV carries a risk of underventilation. Our purpose here was to evaluate the effectiveness of daytime MPV under real-life conditions. Eight wheelchair-bound patients who used MPV underwent daytime polygraphy at home with recordings of airflow, mouthpiece pressure, thoracic and abdominal movements, peripheral capillary oxygen saturation (SpO2), and transcutaneous partial pressure of carbon dioxide (PtcCO2). Times and durations of tasks and activities were recorded. The Apnea–Hypopnea Index (AHI) was computed. Patient–ventilator disconnections ≥3 minutes and episodes of hypoventilation defined as PtcCO2>45 mmHg were counted. Patient–ventilator asynchrony events were analyzed. The AHI was >5 hour−1 in two patients. Another patient experienced unexplained 3% drops in arterial oxygen saturations at a frequency of 70 hour−1. Patient–ventilator disconnections ≥3 minutes occurred in seven of eight patients and were consistently associated with decreases in SpO2 and ≥5-mmHg increases in PtcCO2; PtcCO2 rose above 45 mmHg in two patients during these disconnections. The most common type of patient–ventilator asynchrony was ineffective effort. This study confirms that MPV can be effective as long as the patient remains connected to the mouthpiece. However, transient arterial oxygen desaturation and hypercapnia due to disconnection from the ventilator may occur, without inducing unpleasant sensations in the patients. Therefore, an external warning system based on a minimal acceptable value of minute ventilation would probably be useful. PMID:26703922
Liu, Zhen; Liu, Xiaowen; Huang, Yuguang; Zhao, Jing
2016-01-01
Postoperative pulmonary complications (PPCs), which are not uncommon in one-lung ventilation, are among the main causes of postoperative death after lung surgery. Intra-operative ventilation strategies can influence the incidence of PPCs. High tidal volume (V T) and increased airway pressure may lead to lung injury, while pressure-controlled ventilation and lung-protective strategies with low V T may have protective effects against lung injury. In this meta-analysis, we aim to investigate the effects of different ventilation strategies, including pressure-controlled ventilation (PCV), volume-controlled ventilation (VCV), protective ventilation (PV) and conventional ventilation (CV), on PPCs in patients undergoing one-lung ventilation. We hypothesize that both PV with low V T and PCV have protective effects against PPCs in one-lung ventilation. A systematic search (PubMed, EMBASE, the Cochrane Library, and Ovid MEDLINE; in May 2015) was performed for randomized trials comparing PCV with VCV or comparing PV with CV in one-lung ventilation. Methodological quality was evaluated using the Cochrane tool for risk. The primary outcome was the incidence of PPCs. The secondary outcomes included the length of hospital stay, intraoperative plateau airway pressure (Pplateau), oxygen index (PaO2/FiO2) and mean arterial pressure (MAP). In this meta-analysis, 11 studies (436 patients) comparing PCV with VCV and 11 studies (657 patients) comparing PV with CV were included. Compared to CV, PV decreased the incidence of PPCs (OR 0.29; 95 % CI 0.15-0.57; P < 0.01) and intraoperative Pplateau (MD -3.75; 95 % CI -5.74 to -1.76; P < 0.01) but had no significant influence on the length of hospital stay or MAP. Compared to VCV, PCV decreased intraoperative Pplateau (MD -1.46; 95 % CI -2.54 to -0.34; P = 0.01) but had no significant influence on PPCs, PaO2/FiO2 or MAP. PV with low V T was associated with the reduced incidence of PPCs compared to CV. However, PCV and VCV had similar effects on the incidence of PPCs.
A Comprehensive Approach for the Ergonomic Evaluation of 13 Emergency and Transport Ventilators.
Marjanovic, Nicolas; L'Her, Erwan
2016-05-01
Mechanical ventilation is an important part of emergency medicine and is frequently used for transportation. Human errors during ventilator settings are frequent and may be associated with high morbidity/mortality. The aim of the study was to provide a complete ergonomic evaluation of emergency and transport ventilators, taking into account objective and subjective human-machine interface assessments and individual mental work load. We performed a prospective bench ergonomic evaluation of 13 emergency and transport ventilators, using standardized conditions and a global methodological approach. The study was performed in an evaluation laboratory dedicated to respiratory care, and 12 emergency physicians unfamiliar with the tested devices were included in the evaluation. The ventilators were classified into 3 categories (simple, sophisticated, and ICU-like). Objective chronometric evaluations were conducted considering 9 tasks, and subjective evaluations were performed (ease of use, willingness to use, and user-friendliness of monitoring) using Likert scales. Mental work load evaluation was performed using the NASA Task Load Index scale. Overall task failure rate represented 4% of all attempts. Setting modifications, ventilation mode changes, and powering down durations were different between simple and other emergency and transport ventilator categories (P < .005). There was no difference between ventilator categories for the ease of use and user-friendliness of the monitoring. In contrast, the willingness to use was lower for simple devices, compared with sophisticated and ICU-like emergency and transport ventilators (2.9 ± 1.4 vs 3.9 ± 1.2, P = .002 and 4.3 ± 1, P < .001). No differences were observed between devices regarding the mental work load, except for several specific devices in the sophisticated category. A comprehensive ergonomic evaluation provides valuable information while investigating operational friendliness in emergency and transport ventilators. The choice of a device not only depends on its technical characteristics but should take into account its clinical operational setting and ergonomics in order to decrease mental work load. Sophisticated emergency and transport ventilators should only be used by clinicians who demonstrate expertise in mechanical ventilation. Copyright © 2016 by Daedalus Enterprises.
[FRC measurement in intensive care patients. A definition of standards].
Wauer, H J; Lorenz, B A; Kox, W J
1998-10-01
Determination of Functional Residual Capacity (FRC) can be performed through washout methods, indicator gas dilution or bodyplethysmography. Some of these techniques have been adapted for use in intensive care patients whilst being mechanically ventilated. However, most measurement setups are bulky, cumbersome to use and their running costs are high. Hence FRC measurement has not become a routine method in intensive care although it offers considerable advantages in the management of ventilated patients such as the determination of "best PEEP", the detection of progressive alveolar collapse in the course of acute lung injury and during weaning from mechanical ventilation. Up to now most efforts to improve and simplify FRC measurement were made at the expense of accuracy. An ideal method ought to be accurate, easy to handle and cost-effective. It should supply not only FRC data but also information about intrapulmonary gas distribution and dead space. These demands can be met using modern data acquisition software. The pros and cons of all methods available for FRC measurement are discussed in view of their suitability for intensive care patients. A conventional nitrogen washout using emission spectroscopy for measurement of nitrogen concentration gives satisfying exact values for the determination of the parameters mentioned above. The measurement error can be lowered under 5% by special corrections for flow and nitrogen signal (delay and rise times, changes of gas viscosity). For flow measurement a normal pneumotachograph can be used. Using a laptop computer for data acquisition the bed-side monitor fulfills most of the demands in intensive care. It is then also possible to measure indices of intrapulmonary gas distribution such as Alveolar Mixing Efficiency and Lung Clearance Index.
Respiratory mechanics in mechanically ventilated patients.
Hess, Dean R
2014-11-01
Respiratory mechanics refers to the expression of lung function through measures of pressure and flow. From these measurements, a variety of derived indices can be determined, such as volume, compliance, resistance, and work of breathing. Plateau pressure is a measure of end-inspiratory distending pressure. It has become increasingly appreciated that end-inspiratory transpulmonary pressure (stress) might be a better indicator of the potential for lung injury than plateau pressure alone. This has resulted in a resurgence of interest in the use of esophageal manometry in mechanically ventilated patients. End-expiratory transpulmonary pressure might also be useful to guide the setting of PEEP to counterbalance the collapsing effects of the chest wall. The shape of the pressure-time curve might also be useful to guide the setting of PEEP (stress index). This has focused interest in the roles of stress and strain to assess the potential for lung injury during mechanical ventilation. This paper covers both basic and advanced respiratory mechanics during mechanical ventilation. Copyright © 2014 by Daedalus Enterprises.
Santos-Folgar, Myriam; Otero-Agra, Martín; Fernández-Méndez, Felipe; Hermo-Gonzalo, María Teresa; Barcala-Furelos, Roberto; Rodríguez-Núñez, Antonio
2018-02-08
It has been observed that health professionals have difficulty performing quality cardiopulmonary resuscitation (CPR). The aim of this study was to compare the quality of ventilations performed by Nursing students on an infant model using different methods (mouth-to-mouth-and-nose or bag-valve-mask). A quasi-experimental cross-sectional study was performed that included 46 second-year Nursing students. Two quantitative 4-minute tests of paediatric CPR were performed: a) mouth-to-mouth-and-nose ventilations, and b) ventilations with bag-valve-mask. A Resusci Baby QCPR Wireless SkillReporter® mannequin from Laerdal was used. The proportion of ventilations with adequate, excessive, and insufficient volume was recorded and analysed, as well as the overall quality of the CPR (ventilations and chest compressions). The students were able to give a higher number of ventilations with adequate volume using the mouth-to-mouth-and-nose method (55±22%) than with the bag-valve-mask (28±16%, P<.001). The overall quality of the CPR was also significantly higher when using the mouth-to-mouth-and-nose method (60±19 vs. 48±16%, P<.001). Mouth-to-mouth-and-nose ventilation method is more efficient than bag-valve-mask ventilations in CPR performed by nursing students with a simulated infant model. Copyright © 2018. Publicado por Elsevier España, S.L.U.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warner, J.L.
1993-11-01
This article discusses various aspects of skylights. Designers, builders, and homeowners who understand the energy aspects of skylights can best select them for comfort as well as appearance. Topics covered include heat loss problems (convection, radiation); the sun and the sun angles; ventilation; skylight ratings for efficiency; pointers about what to look for; comparison of skylight and window U-Factors; ventilation. 3 figs., 1 tab.
ERIC Educational Resources Information Center
Shane, Jackie
2012-01-01
This article stresses the importance of building design above technology as a relatively inexpensive way to reduce energy costs for a library. Emphasis is placed on passive solar design for heat and daylighting, but also examines passive ventilation and cooling, green roofs, and building materials. Passive design is weighed against technologies…
2012-02-01
for Low Energy Building Ventilation and Space Conditioning Systems...Building Energy Models ................... 162 APPENDIX D: Reduced-Order Modeling and Control Design for Low Energy Building Systems .... 172 D.1...Design for Low Energy Building Ventilation and Space Conditioning Systems This section focuses on the modeling and control of airflow in buildings
Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings.
MacNaughton, Piers; Pegues, James; Satish, Usha; Santanam, Suresh; Spengler, John; Allen, Joseph
2015-11-18
Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption-Economic and environmental costs. We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person), 30% enhanced ventilation, and 40 cfm/person) and four different heating, ventilation and air conditioning (HVAC) system strategies (Variable Air Volume (VAV) with reheat and a Fan Coil Unit (FCU), both with and without an energy recovery ventilator). We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities). The same change in ventilation improved the performance of workers by 8%, equivalent to a $6500 increase in employee productivity each year. Reduced absenteeism and improved health are also seen with enhanced ventilation. The health benefits associated with enhanced ventilation rates far exceed the per-person energy costs relative to salary costs. Environmental impacts can be mitigated at regional, building, and individual-level scales through the transition to renewable energy sources, adoption of energy efficient systems and ventilation strategies, and promotion of other sustainable policies.
Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings
MacNaughton, Piers; Pegues, James; Satish, Usha; Santanam, Suresh; Spengler, John; Allen, Joseph
2015-01-01
Introduction: Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption—Economic and environmental costs. Methods: We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person), 30% enhanced ventilation, and 40 cfm/person) and four different heating, ventilation and air conditioning (HVAC) system strategies (Variable Air Volume (VAV) with reheat and a Fan Coil Unit (FCU), both with and without an energy recovery ventilator). We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Results: Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities). The same change in ventilation improved the performance of workers by 8%, equivalent to a $6500 increase in employee productivity each year. Reduced absenteeism and improved health are also seen with enhanced ventilation. Conclusions: The health benefits associated with enhanced ventilation rates far exceed the per-person energy costs relative to salary costs. Environmental impacts can be mitigated at regional, building, and individual-level scales through the transition to renewable energy sources, adoption of energy efficient systems and ventilation strategies, and promotion of other sustainable policies. PMID:26593933
Health, Energy Efficiency and Climate Change
Climate change is becoming a driving force for improving energy efficiency because saving energy can help reduce the greenhouse gas emissions that contribute to climate change. However, it is important to balance energy saving measures with ventilation...
A coupled airflow and source/sink model for simulating indoor VOC exposures.
Yang, X; Chen, Q
2001-12-01
In this paper, a numerical model is presented to study the indoor air quality (IAQ) in a room with different emission sources, sinks, and ventilation methods. A computer program, ACCESS-IAQ, is developed to simulate the airflow pattern, the time history of the contaminant concentrations in the occupied zone, and the inhalation exposures. The program developed may be useful for IAQ professional to design healthy and comfortable indoor environments. A numerical study has been carried out to predict the effectiveness of a displacement ventilation and a mixing ventilation on volatile organic compound (VOC) removal in a model office. Results from the numerical predictions show that when a "wet" emission source (a freshly painted wood stain) is distributed uniformly across the floor area with sinks (gypsum board) from the four vertical walls, displacement ventilation has consistently lower exposure at the breathing level of the occupant in the room. Such an effect is mainly due to the higher ventilation efficiency of displacement ventilation compared to the mixing ventilation. The simulation results also show that the walls adsorb significant amounts of VOCs during the first hour and act as secondary sources thereafter.
Practical Insight to Monitor Home NIV in COPD Patients.
Arnal, Jean-Michel; Texereau, Joëlle; Garnero, Aude
2017-08-01
Home noninvasive ventilation (NIV) is used in COPD patients with concomitant chronic hypercapnic respiratory failure in order to correct nocturnal hypoventilation and improve sleep quality, quality of life, and survival. Monitoring of home NIV is needed to assess the effectiveness of ventilation and adherence to therapy, resolve potential adverse effects, reinforce patient knowledge, provide maintenance of the equipment, and readjust the ventilator settings according to the changing condition of the patient. Clinical monitoring is very informative. Anamnesis focuses on the improvement of nocturnal hypoventilation symptoms, sleep quality, and side effects of NIV. Side effects are major cause of intolerance. Screening side effects leads to modification of interface, gas humidification, or ventilator settings. Home care providers maintain ventilator and interface and educate patients for correct use. However, patient's education should be supervised by specialized clinicians. Blood gas measurement shows a significant decrease in PaCO 2 when NIV is efficient. Analysis of ventilator data is very useful to assess daily use, unintentional leaks, upper airway obstruction, and patient ventilator synchrony. Nocturnal oximetry and capnography are additional monitoring tools to assess the impact of NIV on gas exchanges. In the near future, telemonitoring will reinforce and change the organization of home NIV for COPD patients.
Clinical review: Long-term noninvasive ventilation
Robert, Dominique; Argaud, Laurent
2007-01-01
Noninvasive positive ventilation has undergone a remarkable evolution over the past decades and is assuming an important role in the management of both acute and chronic respiratory failure. Long-term ventilatory support should be considered a standard of care to treat selected patients following an intensive care unit (ICU) stay. In this setting, appropriate use of noninvasive ventilation can be expected to improve patient outcomes, reduce ICU admission, enhance patient comfort, and increase the efficiency of health care resource utilization. Current literature indicates that noninvasive ventilation improves and stabilizes the clinical course of many patients with chronic ventilatory failure. Noninvasive ventilation also permits long-term mechanical ventilation to be an acceptable option for patients who otherwise would not have been treated if tracheostomy were the only alternative. Nevertheless, these results appear to be better in patients with neuromuscular/-parietal disorders than in chronic obstructive pulmonary disease. This clinical review will address the use of noninvasive ventilation (not including continuous positive airway pressure) mainly in diseases responsible for chronic hypoventilation (that is, restrictive disorders, including neuromuscular disease and lung disease) and incidentally in others such as obstructive sleep apnea or problems of central drive. PMID:17419882
Histochemical alterations in one lung ventilation.
Yin, Kingsley; Gribbin, Elizabeth; Emanuel, Steven; Orndorff, Rebecca; Walker, Jean; Weese, James; Fallahnejad, Manucher
2007-01-01
One lung ventilation is a commonly performed surgical procedure. Although there have been several reports showing that one-lung ventilation can cause pathophysiological alterations such as pulmonary hypoxic vasoconstriction and intrapulmonary shunting, there have been virtually no reports on the effects of one-lung ventilation on lung histology. Yorkshire pigs (11-17 kg) were anesthetized, a tracheotomy performed and a tracheal tube inserted. The chest was opened and one lung ventilation (OLV), was induced by clamping of the right main bronchus. OLV was continued for 60 min before the clamp was removed and two lung ventilation (TLV) started. TLV was continued for 30 to 60 min. Blood and lung biopsies were taken immediately before OLV, 30 min and 60 min of OLV and after restoration of TLV. Histological analyses revealed that the non-ventilated lung was totally collapsed during OLV. On reventilation, there was clear evidence of vascular congestion and alveolar wall thickening at 30 min after TLV. At 60 min of TLV, there was still vascular congestion. Serum nitrite levels (as an index of nitric oxide production) showed steady decline over the course of the experimental period, reaching a significantly low level on reventilation (compared with baseline levels before OLV). Lung MPO activity (marker of neutrophil sequestration) and serum TNFalpha levels were not raised during the entire experimental period. These results suggest that there was lung vascular injury after OLV, which was associated with reduced levels of nitric oxide production and not associated with an inflammatory response.
Avison, M; Hart, G
2001-06-01
The aim of this study was to reduce airborne contamination resulting from the use of aerosols in lung ventilation scintigraphy. Lung ventilation imaging is frequently performed with 99mTc-diethylenetriaminepentaacetate aerosol (DTPA), derived from a commercial nebuliser. Airborne contamination is a significant problem with this procedure; it results in exposure of staff to radiation and can reduce gamma camera performance when the ventilation is performed in the camera room. We examined the level of airborne contamination resulting from the standard technique with one of the most popular nebuliser kits and tested a modification which significantly reduced airborne contamination. Air contamination was measured while ventilating 122 patients. The modified technique reduced air contamination by a mean value of 64% (p = 0.028) compared with the standard control technique. Additionally, differences in contamination were examined when a mask or mouthpiece was used as well as differences between operators. A simplified method of monitoring air contamination is presented using a commonly available surface contamination monitor. The index so derived was proportional to air contamination (r = 0.88). The problems and regulations associated with airborne contamination are discussed.
Management of mechanical ventilation during laparoscopic surgery.
Valenza, Franco; Chevallard, Giorgio; Fossali, Tommaso; Salice, Valentina; Pizzocri, Marta; Gattinoni, Luciano
2010-06-01
Laparoscopy is widely used in the surgical treatment of a number of diseases. Its advantages are generally believed to lie on its minimal invasiveness, better cosmetic outcome and shorter length of hospital stay based on surgical expertise and state-of-the-art equipment. Thousands of laparoscopic surgical procedures performed safely prove that mechanical ventilation during anaesthesia for laparoscopy is well tolerated by a vast majority of patients. However, the effects of pneumoperitoneum are particularly relevant to patients with underlying lung disease as well as to the increasing number of patients with higher-than-normal body mass index. Moreover, many surgical procedures are significantly longer in duration when performed with laparoscopic techniques. Taken together, these factors impose special care for the management of mechanical ventilation during laparoscopic surgery. The purpose of the review is to summarise the consequences of pneumoperitoneum on the standard monitoring of mechanical ventilation during anaesthesia and to discuss the rationale of using a protective ventilation strategy during laparoscopic surgery. The consequences of chest wall derangement occurring during pneumoperitoneum on airway pressure and central venous pressure, together with the role of end-tidal-CO2 monitoring are emphasised. Ventilatory and non-ventilatory strategies to protect the lung are discussed.
Ventilation Transport Trade Study for Future Space Suit Life Support Systems
NASA Technical Reports Server (NTRS)
Kempf, Robert; Vogel, Matthew; Paul, Heather L.
2008-01-01
A new and advanced portable life support system (PLSS) for space suit surface exploration will require a durable, compact, and energy efficient system to transport the ventilation stream through the space suit. Current space suits used by NASA circulate the ventilation stream via a ball-bearing supported centrifugal fan. As NASA enters the design phase for the next generation PLSS, it is necessary to evaluate available technologies to determine what improvements can be made in mass, volume, power, and reliability for a ventilation transport system. Several air movement devices already designed for commercial, military, and space applications are optimized in these areas and could be adapted for EVA use. This paper summarizes the efforts to identify and compare the latest fan and bearing technologies to determine candidates for the next generation PLSS.
Full-Scale Schlieren Visualization of Commercial Kitchen Ventilation Aerodynamics
NASA Astrophysics Data System (ADS)
Miller, J. D.; Settles, G. S.
1996-11-01
The efficient removal of cooking effluents from commercial kitchens has been identified as the most pressing energy-related issue in the food service industry. A full-scale schlieren optical system with a 2.1x2.7m field-of-view, described at previous APS/DFD meetings, images the convective airflow associated with a typical gas-fired cooking griddle and ventilation hood. Previous attempts to visualize plumes from cooking equipment by smoke and neutrally-buoyant bubbles were not sufficiently keyed to thermal convection. Here, the point where the ventilation hood fails to capture the effluent plume is clearly visible, thus determining the boundary condition for a balanced ventilation system. Further, the strong influence of turbulent entrainment is seen in the behavior of the combustion products vented by the griddle and the interference caused by a makeup-air outlet located too close to the lip of the ventilation hood. Such applications of traditional fluid dynamics techniques and principles are believed to be important to the maturing of ventilation technology. (Research supported by EPRI and IFMA, Inc.)
Ramsey, Kathryn A; Foong, Rachel E; Grdosic, Jasmine; Harper, Alana; Skoric, Billy; Clem, Charles; Davis, Miriam; Turkovic, Lidija; Stick, Stephen M; Davis, Stephanie D; Ranganathan, Sarath C; Hall, Graham L
2017-09-01
The lung clearance index is a measure of ventilation distribution derived from the multiple-breath washout technique. The lung clearance index is increased in the presence of lower respiratory tract inflammation and infection in infants with cystic fibrosis; however, the associations during the preschool years are unknown. We assessed the ability of the lung clearance index to detect the presence and extent of lower respiratory tract inflammation and infection in preschool children with cystic fibrosis. Ventilation distribution outcomes were assessed at 82 visits with 58 children with cystic fibrosis and at 38 visits with 31 healthy children aged 3-6 years. Children with cystic fibrosis also underwent bronchoalveolar lavage fluid collection for detection of lower respiratory tract inflammation and infection. Associations between multiple-breath washout indices and the presence and extent of airway inflammation and infection were assessed using linear mixed effects models. Lung clearance index was elevated in children with cystic fibrosis (mean [SD], 8.00 [1.45]) compared with healthy control subjects (6.67 [0.56]). In cystic fibrosis, the lung clearance index was elevated in individuals with lower respiratory tract infections (difference compared with uninfected [95% confidence interval], 0.62 [0.06, 1.18]) and correlated with the extent of airway inflammation. These data suggest that the lung clearance index may be a useful surveillance tool for monitoring the presence and extent of lower airway inflammation and infection in preschool children with cystic fibrosis.
Rowan, Courtney M; Smith, Lincoln S; Loomis, Ashley; McArthur, Jennifer; Gertz, Shira J; Fitzgerald, Julie C; Nitu, Mara E; Moser, Elizabeth A S; Hsing, Deyin D; Duncan, Christine N; Mahadeo, Kris M; Moffet, Jerelyn; Hall, Mark W; Pinos, Emily L; Tamburro, Robert F; Cheifetz, Ira M
2017-04-01
Immunodeficiency is both a preexisting condition and a risk factor for mortality in pediatric acute respiratory distress syndrome. We describe a series of pediatric allogeneic hematopoietic stem cell transplant patients with pediatric acute respiratory distress syndrome based on the recent Pediatric Acute Lung Injury Consensus Conference guidelines with the objective to better define survival of this population. Secondary analysis of a retrospective database. Twelve U.S. pediatric centers. Pediatric allogeneic hematopoietic stem cell transplant recipients requiring mechanical ventilation. None. During the first week of mechanical ventilation, patients were categorized as: no pediatric acute respiratory distress syndrome or mild, moderate, or severe pediatric acute respiratory distress syndrome based on oxygenation index or oxygen saturation index. Univariable logistic regression evaluated the association between pediatric acute respiratory distress syndrome and PICU mortality. A total of 91.5% of the 211 patients met criteria for pediatric acute respiratory distress syndrome using the Pediatric Acute Lung Injury Consensus Conference definition: 61.1% were severe, 27.5% moderate, and 11.4% mild. Overall survival was 39.3%. Survival decreased with worsening pediatric acute respiratory distress syndrome: no pediatric acute respiratory distress syndrome 66.7%, mild 63.6%, odds ratio = 1.1 (95% CI, 0.3-4.2; p = 0.84), moderate 52.8%, odds ratio = 1.8 (95% CI, 0.6-5.5; p = 0.31), and severe 24.6%, odds ratio = 6.1 (95% CI, 2.1-17.8; p < 0.001). Nonsurvivors were more likely to have multiple consecutive days at moderate and severe pediatric acute respiratory distress syndrome (p < 0.001). Moderate and severe patients had longer PICU length of stay (p = 0.01) and longer mechanical ventilation course (p = 0.02) when compared with those with mild or no pediatric acute respiratory distress syndrome. Nonsurvivors had a higher median maximum oxygenation index than survivors at 28.6 (interquartile range, 15.5-49.9) versus 15.0 (interquartile range, 8.4-29.6) (p < 0.0001). In this multicenter cohort, the majority of pediatric allogeneic hematopoietic stem cell transplant patients with respiratory failure met oxygenation criteria for pediatric acute respiratory distress syndrome based on the Pediatric Acute Lung Injury Consensus Conference definition within the first week of invasive mechanical ventilation. Length of invasive mechanical ventilation, length of PICU stay, and mortality increased as the severity of pediatric acute respiratory distress syndrome worsened.
10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.
Code of Federal Regulations, 2012 CFR
2012-01-01
... seasonal energy efficiency ratio (SEER in British thermal units per Watt-hour (Btu/Wh)), the heating...) Package terminal air conditioners: The energy efficiency ratio (EER in British thermal units per Watt-hour... package vertical air conditioner: The energy efficiency ratio (EER in British thermal units per Watt-hour...
10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.
Code of Federal Regulations, 2013 CFR
2013-01-01
... seasonal energy efficiency ratio (SEER in British thermal units per Watt-hour (Btu/Wh)), the heating...) Package terminal air conditioners: The energy efficiency ratio (EER in British thermal units per Watt-hour... package vertical air conditioner: The energy efficiency ratio (EER in British thermal units per Watt-hour...
Shinoda, Koh; Oba, Jun
2010-03-01
In compliance with health and safety management guidelines against harmful formaldehyde (FA) levels in the gross anatomy laboratory, we newly developed a dissection-table-connected local ventilation system in 2006. The system was composed of (1) a simple plenum-chambered dissection table with low-cost filters, (2) a transparent vinyl flexible duct for easy mounting and removal, which connects the table and the exhaust pipe laid above the ceiling, and (3) an intake creating a downward-flow of air, which was installed on the ceiling just above each table. The dissection table was also designed as a separate-component system, of which the upper plate and marginal suction inlets can be taken apart for cleaning after dissection, and equipped with opening/closing side-windows for picking up materials dropped during dissection and a container underneath the table to receive exudate from the cadaver through a waste-fluid pipe. The local ventilation system dramatically reduced FA levels to 0.01-0.03 ppm in the gross anatomy laboratory room, resulting in no discomforting FA smell and irritating sensation while preserving the student's view of room and line of flow as well as solving the problems of high maintenance cost, sanitation issues inside the table, and working-inconvenience during dissection practice. Switching ventilation methods or power-modes, the current local ventilation system was demonstrated to be more than ten times efficient in FA reduction compared to the whole-room ventilation system and suggested that 11 m3/min/table in exhaust volume should decrease FA levels in both A- and B-measurements to less than 0.1 ppm in 1000 m3 space containing thirty-one 3.5%-FA-fixed cadavers.
Yuan, Ye; Luo, Zhiwen; Liu, Jing; Wang, Yaowu; Lin, Yaoyu
2018-06-01
China is confronted with serious PM 2.5 pollution, especially in the capital city of Beijing. Exposure to PM 2.5 could lead to various negative health impacts including premature mortality. As people spend most of their time indoors, the indoor exposure to PM 2.5 from both indoor and outdoor origins constitutes the majority of personal exposure to PM 2.5 pollution. Different building interventions have been introduced to mitigate indoor PM 2.5 exposure, but always at the cost of energy expenditure. In this study, the health and economic benefits of different ventilation intervention strategies for reducing indoor PM 2.5 exposure are modeled using a representative urban residence in Beijing, with consideration of different indoor PM 2.5 emission strengths and outdoor pollution. Our modeling results show that the increase of envelope air-tightness can achieve significant economic benefits when indoor PM 2.5 emissions are absent; however, if an indoor PM 2.5 source is present, the benefits only increase slightly in mechanically ventilated buildings, but may show negative benefit without mechanical ventilation. Installing mechanical ventilation in Beijing can achieve annual economic benefits ranging from 200yuan/capita to 800yuan/capita if indoor PM 2.5 sources exist. If there is no indoor emission, the annual benefits above 200yuan/capita can be achieved only when the PM 2.5 filtration efficiency is no <90% and the envelope air-tightness is above Chinese National Standard Level 7. Introducing mechanical ventilation with low PM 2.5 filtration efficiency to current residences in urban Beijing will increase the indoor PM 2.5 exposure and result in excess costs to the residents. Copyright © 2018 Elsevier B.V. All rights reserved.
Health effects of home energy efficiency interventions in England: a modelling study
Milner, James; Chalabi, Zaid; Das, Payel; Jones, Benjamin; Shrubsole, Clive; Davies, Mike; Wilkinson, Paul
2015-01-01
Objective To assess potential public health impacts of changes to indoor air quality and temperature due to energy efficiency retrofits in English dwellings to meet 2030 carbon reduction targets. Design Health impact modelling study. Setting England. Participants English household population. Intervention Three retrofit scenarios were modelled: (1) fabric and ventilation retrofits installed assuming building regulations are met; (2) as with scenario (1) but with additional ventilation for homes at risk of poor ventilation; (3) as with scenario (1) but with no additional ventilation to illustrate the potential risk of weak regulations and non-compliance. Main outcome Primary outcomes were changes in quality adjusted life years (QALYs) over 50 years from cardiorespiratory diseases, lung cancer, asthma and common mental disorders due to changes in indoor air pollutants, including secondhand tobacco smoke, PM2.5 from indoor and outdoor sources, radon, mould, and indoor winter temperatures. Results The modelling study estimates showed that scenario (1) resulted in positive effects on net mortality and morbidity of 2241 (95% credible intervals (CI) 2085 to 2397) QALYs per 10 000 persons over 50 years follow-up due to improved temperatures and reduced exposure to indoor pollutants, despite an increase in exposure to outdoor-generated particulate matter with a diameter of 2.5 μm or less (PM2.5). Scenario (2) resulted in a negative impact of −728 (95% CI −864 to −592) QALYs per 10 000 persons over 50 years due to an overall increase in indoor pollutant exposures. Scenario (3) resulted in −539 (95% CI −678 to -399) QALYs per 10 000 persons over 50 years follow-up due to an increase in indoor exposures despite the targeting of pollutants. Conclusions If properly implemented alongside ventilation, energy efficiency retrofits in housing can improve health by reducing exposure to cold and air pollutants. Maximising the health benefits requires careful understanding of the balance of changes in pollutant exposures, highlighting the importance of ventilation to mitigate the risk of poor indoor air quality. PMID:25916488
A Case Study in Market Transformation for Residential Energy Efficiency Programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Building Technologies Office
This case study describes how the Midwest Energy Efficiency Alliance (MEEA) partnered with gas and electric utilities in Iowa to establish the Iowa residential heating, ventilation, and air conditioning System Adjustment and Verified Efficiency (HVAC SAVE) program, taking it to scale improving the performance and energy efficiency of HVAC systems, growing businesses, and gaining consumer trust.
2014-01-01
Background The electrical impedance tomography (EIT)-based global inhomogeneity (GI) index was introduced to quantify tidal volume distribution within the lung. Up to now, the GI index was evaluated for plausibility but the analysis of how it is influenced by various physiological factors is still missing. The aim of our study was to evaluate the influence of proportion of open lung regions measured by EIT on the GI index. Methods A constant low-flow inflation maneuver was performed in 18 acute respiratory distress syndrome (ARDS) patients (58 ± 14 years, mean age ± SD) and 8 lung-healthy patients (41 ± 12 years) under controlled mechanical ventilation. EIT raw data were acquired at 25 scans/s and reconstructed offline. Recruited lung regions were identified as those image pixels of the lung regions within the EIT scans where local impedance amplitudes exceeded 10% of the maximum amplitude during the maneuver. A series of GI indices was calculated during mechanical lung inflation, based on the differential images obtained between different time points. Respiratory system elastance (Ers) values were calculated at 10 lung volume levels during low-flow maneuver. Results The GI index decreased during low-flow inflation, while the percentage of open lung regions increased. The values correlated highly in both ARDS (r2 = 0.88 ± 0.08, p < 0.01) and lung-healthy patients (r2 = 0.92 ± 0.05, p < 0.01). Ers and GI index were also significantly correlated in 16 out of 18 ARDS (r2 = 0.84 ± 0.13, p < 0.01) and in 6 out of 8 lung-healthy patients (r2 = 0.84 ± 0.07, p < 0.01). Significant differences were found in GI values between two groups (0.52 ± 0.21 for ARDS and 0.41 ± 0.04 for lung-healthy patients, p < 0.05) as well in Ers values (0.017 ± 0.008 cmH2O/ml for ARDS and 0.009 ± 0.001 cmH2O/ml for lung-healthy patients, p < 0.01). Conclusions We conclude that the GI index is a reliable measure of ventilation heterogeneity highly correlated with lung recruitability measured with EIT. The GI index may prove to be a useful EIT-based index to guide ventilation therapy. PMID:24502320
[Appropriate dust control measures for jade carving operations].
Liu, Jiang; Wang, Qiushui; Liu, Guangquan
2002-12-01
To provide the appropriate dust control measures for jade carving operations. Dust concentrations in the workplace were measured according to GB/T 5748-85. Ventilation system of dust control were measured according to GB/T 16157-1996. Dust particle size distributions for different sources and particle size fraction collecting efficiencies of the dust collectors were measured with WY-1 in-stack 7 stage cascade impactors. On the basis of adopting wet process in the carving operations, local exhaust ventilation system for dust control was installed, which included: the special designed slot exhaust hoods with hood face velocity of 2.5 m/s and exhaust volume of 600 m3/h. The pipe sizes were determined according to the air volume passing through the pipe and the reasonable air velocities. Impinging scrubber or bag filter dust collector were selected to treat the dust laden air from the local exhaust ventilation system, which gave a total collecting efficiency of 97% for impinging scrubber and 98% for bag filter; The type of fan and its size were selected according to the total air volume of the ventilation system and maximum total pressure needed for the longest pipe line plus the pressure drop of the dust collector. Practical application showed that, after installation and use of the appropriate dust control measures, the dust concentrations in the workplaces could meet or nearly meet the national hygienic standard and the dust laden air at the local exhaust ventilation system could meet the national emission standard.
Performance of heated humidifiers with a heated wire according to ventilatory settings.
Nishida, T; Nishimura, M; Fujino, Y; Mashimo, T
2001-01-01
Delivering warm, humidified gas to patients is important during mechanical ventilation. Heated humidifiers are effective and popular. The humidifying efficiency is influenced not only by performance and settings of the devices but the settings of ventilator. We compared the efficiency of humidifying devices with a heated wire and servo-controlled function under a variety of ventilator settings. A bench study was done with a TTL model lung. The study took place in the laboratory of the University Hospital, Osaka, Japan. Four devices (MR290 with MR730, MR310 with MR730; both Fisher & Paykel, ConchaTherm IV; Hudson RCI, and HummaxII; METRAN) were tested. Hummax II has been developed recently, and it consists of a heated wire and polyethylene microporous hollow fiber. Both wire and fiber were put inside of an inspiratory circuit, and water vapor is delivered throughout the circuit. The Servo 300 was connected to the TTL with a standard ventilator circuit. The ventilator settings were as follows; minute ventilation (V(E)) 5, 10, and 15 L/min, a respiratory rate of 10 breaths/min, I:E ratio 1:1, 1:2, and 1:4, and no applied PEEP. Humidifying devices were set to maintain the temperature of airway opening at 32 degrees C and 37 degrees C. The greater V(E) the lower the humidity with all devices except Hummax II. Hummax II delivered 100% relative humidity at all ventilator and humidifier settings. When airway temperature control of the devices was set at 32 degrees C, the ConchaTherm IV did not deliver 30 mg/L of vapor, which is the value recommended by American National Standards at all V(E) settings. At 10 and 15 L/min of V(E) settings MR310 with MR730 did not deliver recommended vapor, either. In conclusion, airway temperature setting of the humidifying devices influenced the humidity of inspiratory gas greatly. Ventilatory settings also influenced the humidity of inspiratory gas. The Hummax II delivered sufficient water vapor under a variety of minute ventilation.
Contaminant levels, source strengths, and ventilation rates in California retail stores.
Chan, W R; Cohn, S; Sidheswaran, M; Sullivan, D P; Fisk, W J
2015-08-01
This field study measured ventilation rates and indoor air quality in 21 visits to retail stores in California. Three types of stores, such as grocery, furniture/hardware stores, and apparel, were sampled. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California's Title 24 Standard in all but one store. Concentrations of volatile organic compounds (VOCs), ozone, and carbon dioxide measured indoors and outdoors were analyzed. Even though there was adequate ventilation according to standard, concentrations of formaldehyde and acetaldehyde exceeded the most stringent chronic health guidelines in many of the sampled stores. The whole-building emission rates of VOCs were estimated from the measured ventilation rates and the concentrations measured indoor and outdoor. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California's stringent formaldehyde reference level. Given the high costs of providing ventilation, effective source control is an attractive alternative. Field measurements suggest that California retail stores were well ventilated relative to the minimum ventilation rate requirement specified in the Building Energy Efficiency Standards Title 24. Concentrations of formaldehyde found in retail stores were low relative to levels found in homes but exceeded the most stringent chronic health guideline. Looking ahead, California is mandating zero energy commercial buildings by 2030. To reduce the energy use from building ventilation while maintaining or even lowering formaldehyde in retail stores, effective formaldehyde source control measures are vitally important. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
Ye, Yanping; Zhu, Bo; Jiang, Li; Jiang, Qi; Wang, Meiping; Hua, Lin; Xi, Xiuming
2017-07-01
To evaluate the contemporary practice, outcomes, and costs related to mechanical ventilation among ICUs in China. A prospective observational cohort study. Fourteen ICUs among 13 hospitals in Beijing, China. Seven hundred ninety-three patients who received at least 24 hours of mechanical ventilation within the first 48 hours of ICU stay. None. The mean age was 64 years. Sixty-three percent were male. New acute respiratory failure accounted for 85.5% of mechanical ventilation cases. Only 4.7% of the patients received mechanical ventilation for acute exacerbation of chronic obstructive pulmonary disease. The most widely used ventilation mode was the combination of synchronized intermittent mandatory ventilation and pressure support (43.6%). Use of lung-protective ventilation is widespread with tidal volumes of 7.1 mL/kg (2.1 mL/kg). The ICU/hospital mortality was 27.6%/29.3%, respectively (8.5%/9.7% for surgical patients and 41.3%/43.2% for medical patients, respectively). The mean level of ICU/hospital cost per patient was $15,271 (18,940)/$22,946 (25,575), respectively. The mean daily ICU cost per patient was $1,212. For the first time, we obtained a preliminary epidemiology data of mechanical ventilation in Beijing, China, through the study. Compared with the other nations, our patients are older, predominantly male, and treated according to prevailing international guidelines yet at a relatively high cost and high mortality. The expanding elderly population predicts increase demand for mechanical ventilation that must be met by continuous improvement in quality and efficiency of critical care services.
Cohen, I L; Bari, N; Strosberg, M A; Weinberg, P F; Wacksman, R M; Millstein, B H; Fein, I A
1991-10-01
To test the hypothesis that a formal interdisciplinary team approach to managing ICU patients requiring mechanical ventilation enhances ICU efficiency. Retrospective review with cost-effectiveness analysis. A 20-bed medical-surgical ICU in a 450-bed community referral teaching hospital with a critical care fellowship training program. All patients requiring mechanical ventilation in the ICU were included, comparing patients admitted 1 yr before the inception of the ventilatory management team (group 1) with those patients admitted for 1 yr after the inception of the team (group 2). Group 1 included 198 patients with 206 episodes of mechanical ventilation and group 2 included 165 patients with 183 episodes of mechanical ventilation. A team consisting of an ICU attending physician, nurse, and respiratory therapist was formed to conduct rounds regularly and supervise the ventilatory management of ICU patients who were referred to the critical care service. The two study groups were demographically comparable. However, there were significant reductions in resource use in group 2. The number of days on mechanical ventilation decreased (3.9 days per episode of mechanical ventilation [95% confidence interval 0.3 to 7.5 days]), as did days in the ICU (3.3 days per episode of mechanical ventilation [90% confidence interval 0.3 to 6.3 days]), numbers of arterial blood gases (23.2 per episode of mechanical ventilation; p less than .001), and number of indwelling arterial catheters (1 per episode of mechanical ventilation; p less than .001). The estimated cost savings from these reductions was $1,303 per episode of mechanical ventilation. We conclude that a ventilatory management team, or some component thereof, can significantly and safely expedite the process of "weaning" patients from mechanical ventilatory support in the ICU.
Rodrigues, Nelson J O; Oliveira, Ricardo F; Teixeira, Senhorinha F C F; Miguel, Alberto Sérgio; Teixeira, José Carlos; Baptista, João S
2015-01-01
Studies concerning indoor thermal conditions are very important in defining the satisfactory comfort range in health care facilities. This study focuses on the evaluation of the thermal comfort sensation felt by surgeons and nurses, in an orthopaedic surgical room of a Portuguese hospital. Two cases are assessed, with and without the presence of a person. Computational fluid dynamic (CFD) tools were applied for evaluating the predicted mean vote (PMV) index locally. Using average ventilation values to calculate the PMV index does not provide a correct and enough descriptive evaluation of the surgical room thermal environment. As studied for both cases, surgeons feel the environment slightly hotter than nurses. The nurses feel a slightly cold sensation under the air supply diffuser and their neutral comfort zone is located in the air stagnation zones close to the walls, while the surgeons feel the opposite. It was observed that the presence of a person in the room leads to an increase of the PMV index for surgeons and nurses. That goes in line with the empirical knowledge that more persons in a room lead to an increased heat sensation. The clothing used by both classes, as well as the ventilation conditions, should be revised accordingly to the amount of persons in the room and the type of activity performed.
Yoshihisa, Akiomi; Shimizu, Takeshi; Owada, Takashi; Nakamura, Yuichi; Iwaya, Shoji; Yamauchi, Hiroyuki; Miyata, Makiko; Hoshino, Yasuto; Sato, Takamasa; Suzuki, Satoshi; Sugimoto, Koichi; Yamaki, Takayoshi; Kunii, Hiroyuki; Nakazato, Kazuhiko; Suzuki, Hitoshi; Saitoh, Shu-ichi; Takeishi, Yasuchika
2011-01-01
Cheyne-Stokes respiration (CSR) is often observed in patients with chronic heart failure (CHF). Although adaptive servo ventilation (ASV) is effective for CSR, it remains unclear whether ASV improves the cardiac function and prognosis of patients with CHF and CSR.Sixty patients with CHF and CSR (mean left ventricular ejection fraction 38.7%, mean apnea hypopnea index 36.8 times/hour, mean central apnea index 19.1 times/hour) were enrolled in this study. Patients were divided into two groups: 23 patients treated with ASV (ASV group) and 37 patients treated without ASV (Non-ASV group). Measurement of plasma B-type natriuretic peptide (BNP) levels and echocardiography were performed before, 3 and 6 months after treatments in each group. Patients were followed-up for cardiac events (cardiac death and re-hospitalization) after discharge. In the ASV group, NYHA functional class, BNP levels, cardiac systolic and diastolic function were significantly improved with ASV treatment for 6 months. In contrast, none of these parameters changed in the Non-ASV group. Importantly, Kaplan-Meier analysis clearly demonstrated that the event-free rate was significantly higher in the ASV group than in the Non-ASV group.Adaptive servo ventilation improves cardiac function and prognosis in patients with chronic heart failure and Cheyne-Stokes respiration.
Valls-i-Soler, Adolfo; Encinas, Esther; Lukas, John C.; Vozmediano, Valvanera; Suárez, Elena
2014-01-01
Background Fentanyl is widely used off-label in NICU. Our aim was to investigate its cerebral, cardiovascular and pulmonary effects as well as pharmacokinetics in an experimental model for neonates. Methods Fentanyl (5 µg/kg bolus immediately followed by a 90 minute infusion of 3 µg/kg/h) was administered to six mechanically ventilated newborn piglets. Cardiovascular, ventilation, pulmonary and oxygenation indexes as well as brain activity were monitored from T = 0 up to the end of experiments (T = 225–300 min). Also plasma samples for quantification of fentanyl were drawn. Results A “reliable degree of sedation” was observed up to T = 210–240 min, consistent with the selected dosing regimen and the observed fentanyl plasma levels. Unlike cardiovascular parameters, which were unmodified except for an increasing trend in heart rate, some of the ventilation and oxygenation indexes as well as brain activity were significantly altered. The pulmonary and brain effects of fentanyl were mostly recovered from T = 210 min to the end of experiment. Conclusion The newborn piglet was shown to be a suitable experimental model for studying fentanyl disposition as well as respiratory and cardiovascular effects in human neonates. Therefore, it could be extremely useful for further investigating the drug behaviour under pathophysiological conditions. PMID:24595018
Assessment of Factors Related to Auto-PEEP.
Natalini, Giuseppe; Tuzzo, Daniele; Rosano, Antonio; Testa, Marco; Grazioli, Michele; Pennestrì, Vincenzo; Amodeo, Guido; Marsilia, Paolo F; Tinnirello, Andrea; Berruto, Francesco; Fiorillo, Marialinda; Filippini, Matteo; Peratoner, Alberto; Minelli, Cosetta; Bernardini, Achille
2016-02-01
Previous physiological studies have identified factors that are involved in auto-PEEP generation. In our study, we examined how much auto-PEEP is generated from factors that are involved in its development. One hundred eighty-six subjects undergoing controlled mechanical ventilation with persistent expiratory flow at the beginning of each inspiration were enrolled in the study. Volume-controlled continuous mandatory ventilation with PEEP of 0 cm H2O was applied while maintaining the ventilator setting as chosen by the attending physician. End-expiratory and end-inspiratory airway occlusion maneuvers were performed to calculate respiratory mechanics, and tidal flow limitation was assessed by a maneuver of manual compression of the abdomen. The variable with the strongest effect on auto-PEEP was flow limitation, which was associated with an increase of 2.4 cm H2O in auto-PEEP values. Moreover, auto-PEEP values were directly related to resistance of the respiratory system and body mass index and inversely related to expiratory time/time constant. Variables that were associated with the breathing pattern (tidal volume, frequency minute ventilation, and expiratory time) did not show any relationship with auto-PEEP values. The risk of auto-PEEP ≥5 cm H2O was increased by flow limitation (adjusted odds ratio 17; 95% CI: 6-56.2), expiratory time/time constant ratio <1.85 (12.6; 4.7-39.6), respiratory system resistance >15 cm H2O/L s (3; 1.3-6.9), age >65 y (2.8; 1.2-6.5), and body mass index >26 kg/m(2) (2.6; 1.1-6.1). Flow limitation, expiratory time/time constant, resistance of the respiratory system, and obesity are the most important variables that affect auto-PEEP values. Frequency expiratory time, tidal volume, and minute ventilation were not independently associated with auto-PEEP. Therapeutic strategies aimed at reducing auto-PEEP and its adverse effects should be primarily oriented to the variables that mainly affect auto-PEEP values. Copyright © 2016 by Daedalus Enterprises.
Phair, Kristen; West, Gary; Biller, David
2010-12-01
Radiography is a valuable tool for assessment of pulmonary disease. Specifically, radiographs utilizing positive pressure ventilation can distinguish between anesthesia-induced atelectasis and pulmonary disease when survey radiographs are ambiguous. Positive pressure ventilation can be used to radiographically prove or disprove pulmonary disease. This is of particular clinical importance when working with exotic, zoo, or wildlife species because the majority of these patients require general anesthesia to perform physical examinations and diagnostics such as radiography safely and efficiently. This report is a case example of pulmonary disease in a red panda (Ailurus fulgens) and demonstrates how positive pressure ventilation verified both the presence of pulmonary disease and the eventual resolution of the disease. Anesthetized patients on gas anesthesia will rapidly become atelectic. Through the use of positive pressure ventilation, anesthesia-induced atelectasis and true pulmonary disease can readily be distinguished. This is a technique that should not be overlooked when performing thoracic radiography in zoo species.
Space station ventilation study
NASA Technical Reports Server (NTRS)
Colombo, G. V.; Allen, G. E.
1972-01-01
A ventilation system design and selection method which is applicable to any manned vehicle were developed. The method was used to generate design options for the NASA 33-foot diameter space station, all of which meet the ventilation system design requirements. System characteristics such as weight, volume, and power were normalized to dollar costs for each option. Total system costs for the various options ranged from a worst case $8 million to a group of four which were all approximately $2 million. A system design was then chosen from the $2 million group and is presented in detail. A ventilation system layout was designed for the MSFC space station mockup which provided comfortable, efficient ventilation of the mockup. A conditioned air distribution system design for the 14-foot diameter modular space station, using the same techniques, is also presented. The tradeoff study resulted in the selection of a system which costs $1.9 million, as compared to the alternate configuration which would have cost $2.6 million.
Trending autoregulatory indices during treatment for traumatic brain injury.
Kim, Nam; Krasner, Alex; Kosinski, Colin; Wininger, Michael; Qadri, Maria; Kappus, Zachary; Danish, Shabbar; Craelius, William
2016-12-01
Our goal is to use automatic data monitoring for reliable prediction of episodes of intracranial hypertension in patients with traumatic brain injury. Here we test the validity of our method on retrospective patient data. We developed the Continuous Hemodynamic Autoregulatory Monitor (CHARM), that siphons and stores signals from existing monitors in the surgical intensive care unit (SICU), efficiently compresses them, and standardizes the search for statistical relationships between any proposed index and adverse events. CHARM uses an automated event detector to reliably locate episodes of elevated intracranial pressure (ICP), while eliminating artifacts within retrospective patient data. A graphical user interface allowed data scanning, selection of criteria for events, and calculating indices. The pressure reactivity index (PRx), defined as the least square linear regression slope of intracranial pressure versus arterial BP, was calculated for a single case that spanned 259 h. CHARM collected continuous records of ABP, ICP, ECG, SpO2, and ventilation from 29 patients with TBI over an 18-month period. Analysis of a single patient showed that PRx data distribution in the single hours immediately prior to all 16 intracranial hypertensive events, significantly differed from that in the 243 h that did not precede such events (p < 0.0001). The PRx index, however, lacked sufficient resolution as a real-time predictor of IH in this patient. CHARM streamlines the search for reliable predictors of intracranial hypertension. We report statistical evidence supporting the predictive potential of the pressure reactivity index.
Impact of Fire Ventilation on General Ventilation in the Building
NASA Astrophysics Data System (ADS)
Zender-Świercz, Ewa; Telejko, Marek
2017-10-01
The fire of building is a threat to its users. The biggest threat is generation, during lifetime of fire, hot gases and smoke. The purpose of quick and efficient evacuation from the area covered by the fire, at first step the escape routes have to be secured from smokiness. The smoke ventilation systems are used for this purpose. The proper design and execution of smoke ventilation is important not only because of the safety, but also of the maintenance of comfort in the building at a time when there is no fire. The manuscript presents the effect of incorrectly realized smoke ventilation in the stairwell of the medium building. The analysis shows that the flaps of smoke ventilation located in the stairwell may have a significant impact on the proper functioning of mechanical ventilation in the period when there is no fire. The improperly installed or incorrect insulated components cause perturbation of air flow and they change pressure distribution in the building. The conclusion of the analysis is the need to include the entire technical equipment of the building during the design and realization of its individual elements. The impact of various installations at each other is very important, and the omission of any of them can cause disturbances in the proper work of another.
Kalema, T; Viot, M
2014-02-01
The aim of this study is to develop internal ventilation by transferred air to achieve a good indoor climate with low energy consumption in educational buildings with constant air volume (CAV) ventilation. Both measurements of CO2 concentration and a multi-room calculation model are presented. The study analyzes how to use more efficiently the available spaces and the capacity of CAV ventilation systems in existing buildings and the impact this has on the indoor air quality and the energy consumption of the ventilation. The temperature differences can be used to create natural ventilation airflows between neighboring spaces. The behavior of temperature-driven airflows between rooms was studied and included in the calculation model. The effect of openings between neighboring spaces, such as doors or large apertures in the walls, on the CO2 concentration was studied in different classrooms. The air temperatures and CO2 concentrations were measured using a wireless, internet-based measurement system. The multi-room calculation model predicted the CO2 concentration in the rooms, which was then compared with the measured ones. Using transferred air between occupied and unoccupied spaces can noticeably reduce the total mechanical ventilation rates needed to keep a low CO2 concentration. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chan, Wanyu R.; Sidheswaran, Meera; Cohn, Sebastian
2014-02-01
This field study measured ventilation rates and indoor air quality parameters in 21 visits to retail stores in California. The data was collected to guide the development of new, science-based commercial building ventilation rate standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. Data collection occurred between September 2011 and March 2013. Three types of stores participated in this study: grocery stores, furniture/hardware stores, and apparel stores. Ventilation rates and indoor air contaminant concentrations were measured on a weekday, typically between 9 am and 6 pm. Ventilation rates measured using a tracer gasmore » decay method exceeded the minimum requirement of California’s Title 24 Standard in all but one store. Even though there was adequate ventilation according to Title 24, concentrations of formaldehyde, acetaldehyde, and acrolein exceeded the most stringent chronic health guidelines. Other indoor air contaminants measured included carbon dioxide (CO{sub 2}), carbon monoxide (CO), ozone (O{sub 3}), and particulate matter (PM). Concentrations of CO{sub 2} were kept low by adequate ventilation, and were assumed low also because the sampling occurred on a weekday when retail stores were less busy. CO concentrations were also low. The indoor-outdoor ratios of O{sub 3} showed that the first-order loss rate may vary by store trade types and also by ventilation mode (mechanical versus natural). Analysis of fine and ultrafine PM measurements showed that a substantial portion of the particle mass in grocery stores with cooking-related emissions was in particles less than 0.3 μm. Stores without cooking as an indoor source had PM size distributions that were more similar indoors and outdoors. The whole-building emission rates of volatile organic compounds (VOCs) and PM were estimated from the measured ventilation rates and indoor and outdoor contaminant concentrations. Mass balance models were then used to determine the ventilation rates, filtration strategies, or source reductions needed to maintain indoor contaminant concentrations below reference levels. Several scenarios of potential concern were considered: (i) formaldehyde levels in furniture/hardware stores, (ii) contaminants associated with cooking (e.g., PM, acrolein, and acetaldehyde) in grocery stores, and (iii) outdoor contaminants (e.g., PM and O{sub 3}) impacting stores that use natural ventilation. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California’s stringent formaldehyde reference level. Given the high costs of providing ventilation but only modest chronic health benefit is expected, effective source control is an attractive alternative, as demonstrated by some retail stores in this study. Predictions showed that grocery stores need MERV 13 air filters, instead of MERV 8 filters that are more commonly used, to maintain indoor PM at levels that meet the chronic health standards for PM. Exposure to acrolein is a potential health concern in grocery stores, and should be addressed by increasing the use of kitchen range hoods or improving their contaminant removal efficiency. In stores that rely on natural ventilation, indoor PM can be a health concern if the stores are located in areas with high outdoor PM. This concern may be addressed by switching to mechanical ventilation when the outdoor air quality is poor, while continuing natural ventilation when outdoor air quality is good.« less
Fietze, Ingo; Blau, Alexander; Glos, Martin; Theres, Heinz; Baumann, Gert; Penzel, Thomas
2008-08-01
Nocturnal positive pressure ventilation (PPV) has been shown to be effective in patients with impaired left ventricular ejection fraction (LVEF) and Cheyne-Stokes respiration (CSR). We investigated the effect of a bi-level PPV and adaptive servo ventilation on LVEF, CSR, and quantitative sleep quality. Thirty-seven patients (New York heart association [NYHA] II-III) with LVEF<45% and CSR were investigated by electrocardiography (ECG), echocardiography and polysomnography. The CSR index (CSRI) was 32.3+/-16.2/h. Patients were randomly treated with bi-level PPV using the standard spontaneous/timed (S/T) mode or with adaptive servo ventilation mode (AutoSetCS). After 6 weeks, 30 patients underwent control investigations with ECG, echocardiography, and polysomnography. The CSRI decreased significantly to 13.6+/-13.4/h. LVEF increased significantly after 6 weeks of ventilation (from 25.1+/-8.5 to 28.8+/-9.8%, p<0.01). The number of respiratory-related arousals decreased significantly. Other quantitative sleep parameters did not change. The Epworth sleepiness score improved slightly. Daytime blood pressure and heart rate did not change. There were some differences between bi-level PPV and adaptive servo ventilation: the CSRI decreased more in the AutoSetCS group while the LVEF increased more in the bi-level PPV group. Administration of PPV can successfully attenuate CSA. Reduced CSA may be associated with improved LVEF; however, this may depend on the mode of PPV. Changed LVEF is evident even in the absence of significant changes in blood pressure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kull, K.
1988-09-01
This article describes and compares ventilation systems for the control of indoor air pollution in residential housing. These include: local exhaust fans, whole-house fans, central exhaust with wall ports, and heat-recovery central ventilation (HRV). HRV's have a higher initial cost than the other systems but they are the only ones that save energy. Homeowners are given guidelines for choosing the system best suited for their homes in terms of efficiency and payback period.
n-Hexane polyneuropathy in a ball-manufacturing factory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, C.C.; Shih, T.S.; Cheng, S.Y.
Five overt and two occult cases of n-hexane polyneuropathy occurred in a ball-manufacturing factory in Taiwan. The severity of polyneuropathy was directly related to the index of n-hexane exposure that occurred during the processes of cement coating and nylon fiber winding in a poorly ventilated room. The n-hexane concentrations over eight hours of personal sampling of the air of the cement coating and nylon fiber winding areas were 109 ppm and 86 ppm, respectively. After installation of a new factory ventilation system, these seven patients recovered completely, and there were no new cases in the two-year follow-up.
10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.
Code of Federal Regulations, 2014 CFR
2014-01-01
... conditioners: The energy efficiency ratio (EER in British thermal units per Watt-hour (Btu/Wh)), the cooling...) Package terminal heat pumps: The energy efficiency ratio (EER in British thermal units per Watt-hour (Btu...: The energy efficiency ratio (EER in British thermal units per Watt-hour (Btu/Wh)) and the cooling...
Lu, Chih-Cherng; Lin, Tso-Chou; Hsu, Che-Hao; Yu, Mu-Hsien; Ku, Chih-Hung; Chen, Ta-Liang; Chen, Ruei-Ming; Ho, Shung-Tai
2013-02-01
We investigated whether ventilation volumes affected arterial blood sevoflurane concentration (A (sev)) and its uptake into the body during general anesthesia. Thirty female patients undergoing elective gynecologic surgery were randomly allocated into three groups: hyperventilation, normal ventilation, and hypoventilation. Inspiratory (CI(sev)) and end-tidal ((sev)) sevoflurane concentrations were routinely measured by infrared analysis, and A (sev) were analyzed by gas chromatography for 40 min after intubation. Cardiac index and total peripheral vascular resistance were measured with a Finometer. During the first 10 min after sevoflurane administration, A (sev) in the hyperventilation group was the highest and differed significantly from those in the normal ventilation group, followed by those in the hypoventilation group. In addition, hyperventilation significantly increased the slope of A (sev) over time in the first 5 min, but there were no differences in slopes in the 5-10, 10-20, and 20-40 min periods, which indicates no difference in sevoflurane bodily uptake among the three groups after 5 min. Hyperventilation accelerated the rate of A (sev) increase immediately after sevoflurane administration, which was time dependent with respect to different alveolar ventilation levels.
Quera-Salva, M A; McCann, C; Boudet, J; Frisk, M; Borderies, P; Meyer, P
1994-01-01
1. In a double-blind, crossover, placebo controlled trial, zolpidem 10 mg, a new imidazopyridine hypnotic drug, was administered in a single dose to 10 healthy non-obese heavy snorers. 2. Nocturnal polysomnography showed that zolpidem increased total sleep time, sleep efficiency and the percentage of stage 2. 3. Respiratory monitoring showed that zolpidem did not modify the percentage of total sleep time spent snoring. The percentages of total sleep time with a SaO2 < 4% of the baseline value and with a SaO2 < 90% and the mean SaO2 were also unchanged with zolpidem. The respiratory disturbance index was modestly increased by zolpidem although in all but one subject it remained < 5 with both treatments. 4. Zolpidem intake did not impair daytime vigilance and performance evaluated the day after. PMID:7917771
Na, J U; Han, S K; Choi, P C; Cho, J H; Shin, D H
2013-10-01
Different face mask designs can influence bag-valve-mask (BVM) ventilation performance during resuscitation. We compared a single-use, air-cushioned face mask (AM) with a reusable silicone face mask (SM) for quality of BVM ventilation on a manikin simulating cardiac arrest. Thirty-two physicians were recruited, and a prospective, randomized, crossover observational study was conducted after an American Heart Association-accredited basic life support provider course and standardized practice time were completed. Participants performed 12 cycles of BVM ventilation with both the AM and SM on a SmartMan lung simulator. Mean tidal volume was significantly higher in ventilations performed using the AM vs. the SM (548 ± 159 ml vs. 439 ± 163 ml, P < 0.01). In addition, the proportion of low-volume ventilation was significantly lower with the AM than the SM [6/12 (2-11) vs. 9/12 (5-12), P = 0.03]. Bag-valve-AM ventilation volume was not affected by the physical characteristics of the rescuers, except for sex. In contrast, bag-valve-SM ventilation volume was affected by most of the characteristics tested, including sex, height, weight, hand width, hand length, and grip power. The AM seems to be a more efficient face mask than the SM at delivering sufficient ventilation volumes. The performance of the AM did not seem to be associated with the physical characteristics of the rescuers, whereas that of the SM was affected by these factors. The SM may not be an appropriate face mask for performing one-person BVM ventilation during resuscitation for rescuers who are smaller in stature, have a smaller hand size, or have weaker grip power. © 2013 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Oswiecinska, A.; Hibbs, J.; Zajic, I.; Burnham, K. J.
2015-11-01
This paper presents conceptual control solution for reliable and energy efficient operation of heating, ventilation and air conditioning (HVAC) systems used in large volume building applications, e.g. warehouse facilities or exhibition centres. Advanced two-level scalable control solution, designed to extend capabilities of the existing low-level control strategies via remote internet connection, is presented. The high-level, supervisory controller is based on Model Predictive Control (MPC) architecture, which is the state-of-the-art for indoor climate control systems. The innovative approach benefits from using passive heating and cooling control strategies for reducing the HVAC system operational costs, while ensuring that required environmental conditions are met.
Elliott, Ann R.; Prisk, G. Kim; Darquenne, Chantal
2017-01-01
Multiple breath washout (MBW) and oxygen-enhanced MRI techniques use acute exposure to 100% oxygen to measure ventilation heterogeneity. Implicit is the assumption that breathing 100% oxygen does not induce changes in ventilation heterogeneity; however, this is untested. We hypothesized that ventilation heterogeneity decreases with increasing inspired oxygen concentration in healthy subjects. We performed MBW in 8 healthy subjects (4 women, 4 men; age = 43 ± 15 yr) with normal pulmonary function (FEV1 = 98 ± 6% predicted) using 10% argon as a tracer gas and oxygen concentrations of 12.5%, 21%, or 90%. MBW was performed in accordance with ERS-ATS guidelines. Subjects initially inspired air followed by a wash-in of test gas. Tests were performed in balanced order in triplicate. Gas concentrations were measured at the mouth, and argon signals rescaled to mimic a N2 washout, and analyzed to determine the distribution of specific ventilation (SV). Heterogeneity was characterized by the width of a log-Gaussian fit of the SV distribution and from Sacin and Scond indexes derived from the phase III slope. There were no significant differences in the ventilation heterogeneity due to altered inspired oxygen: histogram width (hypoxia 0.57 ± 0.11, normoxia 0.60 ± 0.08, hyperoxia 0.59 ± 0.09, P = 0.51), Scond (hypoxia 0.014 ± 0.011, normoxia 0.012 ± 0.015, hyperoxia 0.010 ± 0.011, P = 0.34), or Sacin (hypoxia 0.11 ± 0.04, normoxia 0.10 ± 0.03, hyperoxia 0.12 ± 0.03, P = 0.23). Functional residual capacity was increased in hypoxia (P = 0.04) and dead space increased in hyperoxia (P = 0.0001) compared with the other conditions. The acute use of 100% oxygen in MBW or MRI is unlikely to affect ventilation heterogeneity. NEW & NOTEWORTHY Hyperoxia is used to measure the distribution of ventilation in imaging and MBW but may alter the underlying ventilation distribution. We used MBW to evaluate the effect of inspired oxygen concentration on the ventilation distribution using 10% argon as a tracer. Short-duration exposure to hypoxia (12.5% oxygen) and hyperoxia (90% oxygen) during MBW had no significant effect on ventilation heterogeneity, suggesting that hyperoxia can be used to assess the ventilation distribution. PMID:28280107
Hopkins, Susan R; Elliott, Ann R; Prisk, G Kim; Darquenne, Chantal
2017-06-01
Multiple breath washout (MBW) and oxygen-enhanced MRI techniques use acute exposure to 100% oxygen to measure ventilation heterogeneity. Implicit is the assumption that breathing 100% oxygen does not induce changes in ventilation heterogeneity; however, this is untested. We hypothesized that ventilation heterogeneity decreases with increasing inspired oxygen concentration in healthy subjects. We performed MBW in 8 healthy subjects (4 women, 4 men; age = 43 ± 15 yr) with normal pulmonary function (FEV 1 = 98 ± 6% predicted) using 10% argon as a tracer gas and oxygen concentrations of 12.5%, 21%, or 90%. MBW was performed in accordance with ERS-ATS guidelines. Subjects initially inspired air followed by a wash-in of test gas. Tests were performed in balanced order in triplicate. Gas concentrations were measured at the mouth, and argon signals rescaled to mimic a N 2 washout, and analyzed to determine the distribution of specific ventilation (SV). Heterogeneity was characterized by the width of a log-Gaussian fit of the SV distribution and from S acin and S cond indexes derived from the phase III slope. There were no significant differences in the ventilation heterogeneity due to altered inspired oxygen: histogram width (hypoxia 0.57 ± 0.11, normoxia 0.60 ± 0.08, hyperoxia 0.59 ± 0.09, P = 0.51), S cond (hypoxia 0.014 ± 0.011, normoxia 0.012 ± 0.015, hyperoxia 0.010 ± 0.011, P = 0.34), or S acin (hypoxia 0.11 ± 0.04, normoxia 0.10 ± 0.03, hyperoxia 0.12 ± 0.03, P = 0.23). Functional residual capacity was increased in hypoxia ( P = 0.04) and dead space increased in hyperoxia ( P = 0.0001) compared with the other conditions. The acute use of 100% oxygen in MBW or MRI is unlikely to affect ventilation heterogeneity. NEW & NOTEWORTHY Hyperoxia is used to measure the distribution of ventilation in imaging and MBW but may alter the underlying ventilation distribution. We used MBW to evaluate the effect of inspired oxygen concentration on the ventilation distribution using 10% argon as a tracer. Short-duration exposure to hypoxia (12.5% oxygen) and hyperoxia (90% oxygen) during MBW had no significant effect on ventilation heterogeneity, suggesting that hyperoxia can be used to assess the ventilation distribution. Copyright © 2017 the American Physiological Society.
Kerr, Carolyn L; Windeyer, Claire; Bouré, Ludovic P; Mirakhur, Kuldip K; McDonell, Wayne
2007-12-01
To compare the cardiopulmonary effects of administration of a solution of xylazine, guaifenesin, and ketamine (XGK) or inhaled isoflurane in mechanically ventilated calves undergoing surgery. 13 male calves 2 to 26 days of age. Procedures-In calves in the XGK group, anesthesia was induced (0.5 mL/kg) and maintained (2.5 mL/kg/h) with a combination solution of xylazine (0.1 mg/mL), guaifenesin (50 mg/mL), and ketamine (1.0 mg/mL). For calves in the isoflurane group, anesthesia was induced and maintained with isoflurane in oxygen. The rates of XGK infusion and isoflurane administration were adjusted to achieve suitable anesthetic depth. All calves received 100% oxygen and were mechanically ventilated to maintain end-tidal carbon dioxide concentrations from 35 to 40 mm Hg and underwent laparoscopic bladder surgery through an abdominal approach. Cardiopulmonary variables were measured before induction and at intervals up to 90 minutes after anesthetic induction. The quality of induction was excellent in all calves. The XGK requirements were 0.57 +/- 0.18 mL/kg and 2.70 +/- 0.40 mL/kg/h to induce and maintain anesthesia, respectively. Heart rate was significantly lower than baseline throughout the anesthetic period in the XGK group. Systolic arterial blood pressure was significantly higher in the XGK group, compared with the isoflurane group, from 5 to 90 minutes. Cardiac index was lower than baseline in both groups. Differences between groups in cardiac index and arterial blood gas values were not significant. Administration of XGK resulted in excellent anesthetic induction and maintenance with cardiopulmonary alterations similar to those associated with isoflurane in mechanically ventilated calves.
Han, Yun; Zhou, Lixin; He, Weiqun; Chen, Sibei; Nong, Lingbo; Huang, Huang; Zhang, Yan; Yu, Tieou; Li, Yimin; Liu, Xiaoqing
2015-01-01
Background Patients with H7N9 avian flu concurrent with severe acute respiratory distress syndrome (ARDS) usually have a poor clinical outcome. Prone position ventilation (PPV) has been shown to improve the prognosis of patients with severe ARDS. This study explored the effects of PPV on the respiratory and circulatory mechanics of H7N9-infected patients with severe ARDS. Methods Individuals admitted to four hospitals designated for H7N9 patients in Guangdong province were treated with PPV, and their clinical data were recorded before and after receiving PPV. Results Six of 20 critically ill patients in the ICU received PPV. After treatment with 35 PPV sessions, the oxygenation index (OI) values of the six patients when measured post-PPV and post-supine position ventilation (SPV) were significantly higher than those measured pre-PPV (P < 0.05).The six patients showed no significant differences in their values for respiratory rate (RR), peak inspiratory pressure (PIP), tidal volume (TV) or arterial partial pressure of carbon dioxide (PaCO2) when compared pre-PPV, post-PPV, and post-SPV. Additionally, there were no significant differences in the mean values for arterial pressure (MAP), cardiac index (CI), central venous pressure (CVP), heart rate (HR), lactic acid (LAC) levels or the doses of norepinephrine (NE) administered when compared pre-PPV, post-PPV, and post-SPV. Conclusion PPV provided improved oxygenation that was sustained after returning to a supine position, and resulted in decreased carbon dioxide retention. PPV can thus serve as an alternative lung protective ventilation strategy for use in patients with H7N9 avian flu concurrent with severe ARDS. PMID:26317621
Xu, Yuanda; Deng, Xilong; Han, Yun; Zhou, Lixin; He, Weiqun; Chen, Sibei; Nong, Lingbo; Huang, Huang; Zhang, Yan; Yu, Tieou; Li, Yimin; Liu, Xiaoqing
2015-01-01
Patients with H7N9 avian flu concurrent with severe acute respiratory distress syndrome (ARDS) usually have a poor clinical outcome. Prone position ventilation (PPV) has been shown to improve the prognosis of patients with severe ARDS. This study explored the effects of PPV on the respiratory and circulatory mechanics of H7N9-infected patients with severe ARDS. Individuals admitted to four hospitals designated for H7N9 patients in Guangdong province were treated with PPV, and their clinical data were recorded before and after receiving PPV. Six of 20 critically ill patients in the ICU received PPV. After treatment with 35 PPV sessions, the oxygenation index (OI) values of the six patients when measured post-PPV and post-supine position ventilation (SPV) were significantly higher than those measured pre-PPV (P < 0.05).The six patients showed no significant differences in their values for respiratory rate (RR), peak inspiratory pressure (PIP), tidal volume (TV) or arterial partial pressure of carbon dioxide (PaCO2) when compared pre-PPV, post-PPV, and post-SPV. Additionally, there were no significant differences in the mean values for arterial pressure (MAP), cardiac index (CI), central venous pressure (CVP), heart rate (HR), lactic acid (LAC) levels or the doses of norepinephrine (NE) administered when compared pre-PPV, post-PPV, and post-SPV. PPV provided improved oxygenation that was sustained after returning to a supine position, and resulted in decreased carbon dioxide retention. PPV can thus serve as an alternative lung protective ventilation strategy for use in patients with H7N9 avian flu concurrent with severe ARDS.
Pulmonary edema in meningococcal septicemia associated with reduced epithelial chloride transport.
Eisenhut, Michael; Wallace, Helen; Barton, Paul; Gaillard, Erol; Newland, Paul; Diver, Michael; Southern, Kevin W
2006-03-01
To test the hypothesis that meningococcal septicemia-related pulmonary edema is associated with a systemic abnormality of epithelial sodium and chloride transport and to investigate an association with hormones regulating Na transport. Prospective observational study. The 24-bed pediatric intensive care unit and pediatric wards of Royal Liverpool Children's Hospital. Consecutive children admitted to the pediatric intensive care unit and pediatric wards with a diagnosis of meningococcal septicemia and children (controls) with noninfectious critical illness receiving ventilatory support in the pediatric intensive care unit. We measured sweat and saliva electrolytes, renal electrolyte excretion, nasal potential difference, and aldosterone, thyroxine, and cortisol levels. Pulmonary edema was diagnosed by chest radiography and its severity quantified by calculation of ventilation index at admission and duration of mechanical ventilation. We recruited 17 patients with severe meningococcal septicemia (nine patients with pulmonary edema), 14 patients with mild meningococcal septicemia, and 20 controls. Sweat and saliva Na and Cl concentrations and renal Na excretion were significantly (p < .05) higher in patients with pulmonary edema compared with controls. Nasal potential difference and amiloride response in patients with pulmonary edema were not significantly different to controls, but response to a low Cl solution was reduced in the nasal airway of patients with pulmonary edema (p < .05). Sweat and saliva chloride concentrations correlated significantly and better with ventilation index and duration of ventilation than sodium concentrations. Aldosterone, thyroxine, and cortisol levels were not significantly different between groups. We have confirmed that meningococcal septicemia-related pulmonary edema is associated with reduced systemic sodium and chloride transport. Features of reduced Cl transport were most closely associated with markers of respiratory compromise, and this was supported by the reduced chloride channel function detected on nasal potential difference measurement.
Bramley, Anna M; Reed, Carrie; Finelli, Lyn; Self, Wesley H; Ampofo, Krow; Arnold, Sandra R; Williams, Derek J; Grijalva, Carlos G; Anderson, Evan J; Stockmann, Chris; Trabue, Christopher; Fakhran, Sherene; Balk, Robert; McCullers, Jonathan A; Pavia, Andrew T; Edwards, Kathryn M; Wunderink, Richard G; Jain, Seema
2017-06-15
The effect of body mass index (BMI) on community-acquired pneumonia (CAP) severity is unclear. We investigated the relationship between BMI and CAP outcomes (hospital length of stay [LOS], intensive care unit [ICU] admission, and invasive mechanical ventilation) in hospitalized CAP patients from the Centers for Disease Control and Prevention Etiology of Pneumonia in the Community (EPIC) study, adjusting for age, demographics, underlying conditions, and smoking status (adults only). Compared with normal-weight children, odds of ICU admission were higher in children who were overweight (adjusted odds ratio [aOR], 1.7; 95% confidence interval [CI], 1.1-2.8) or obese (aOR, 2.1; 95% CI, 1.4-3.2), and odds of mechanical ventilation were higher in children with obesity (aOR, 2.7; 95% CI, 1.3-5.6). When stratified by asthma (presence/absence), these findings remained significant only in children with asthma. Compared with normal-weight adults, odds of LOS >3 days were higher in adults who were underweight (aOR, 1.6; 95% CI, 1.1-2.4), and odds of mechanical ventilation were lowest in adults who were overweight (aOR, 0.5; 95% CI, .3-.9). Children who were overweight or obese, particularly those with asthma, had higher odds of ICU admission or mechanical ventilation. In contrast, adults who were underweight had longer LOS. These results underscore the complex relationship between BMI and CAP outcomes. Published by Oxford University Press for the Infectious Diseases Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Ebrahimabadi, Sahar; Moghadam, Ahmad Bagheri; Vakili, Mohammadali; Modanloo, Mahnaz; Khoddam, Homeira
2017-08-01
The use of weaning predictive indicators can avoid early extubation and wrongful prolonged mechanical ventilation. This study aimed to determine the power of the integrative weaning index (IWI) in predicting the success rate of the spontaneous breathing trial (SBT) in patients under mechanical ventilation. In this prospective study, 105 patients undergoing mechanical ventilation for over 48 h were enrolled. Before weaning initiation, the IWI was calculated and based on the defined cutoff point (≥25), the success rate of the SBT was predicted. In case of weaning from the device, 2-h SBT was performed and the physiologic and respiratory indices were continuously studied while being intubated. If they were in the normal range besides the patient's tolerance, the test was considered as a success. The result was then compared with the IWI and further analyzed. The SBT was successful in 90 (85.7%) and unsuccessful in 15 (14.3%) cases. The difference between the true patient outcome after SBT, and the IWI prediction was 0.143 according to the Kappa agreement coefficient ( P < 0.001). Moreover, regarding the predictive power, IWI had high sensitivity (95.6%), specificity (40%), positive and negative predictive values (90.5% and 60), positive and negative likelihood ratios (1.59 and 0.11), and accuracy (86.7%). The IWI as a more objective indicator has acceptable accuracy and power for predicting the 2-h SBT result. Therefore, in addition to the reliable prediction of the final weaning outcome, it has favorable power to predict if the patient is ready to breathe spontaneously as the first step to weaning.
Ebrahimabadi, Sahar; Moghadam, Ahmad Bagheri; Vakili, Mohammadali; Modanloo, Mahnaz; Khoddam, Homeira
2017-01-01
Background and Aims: The use of weaning predictive indicators can avoid early extubation and wrongful prolonged mechanical ventilation. This study aimed to determine the power of the integrative weaning index (IWI) in predicting the success rate of the spontaneous breathing trial (SBT) in patients under mechanical ventilation. Materials and Methods: In this prospective study, 105 patients undergoing mechanical ventilation for over 48 h were enrolled. Before weaning initiation, the IWI was calculated and based on the defined cutoff point (≥25), the success rate of the SBT was predicted. In case of weaning from the device, 2-h SBT was performed and the physiologic and respiratory indices were continuously studied while being intubated. If they were in the normal range besides the patient's tolerance, the test was considered as a success. The result was then compared with the IWI and further analyzed. Results: The SBT was successful in 90 (85.7%) and unsuccessful in 15 (14.3%) cases. The difference between the true patient outcome after SBT, and the IWI prediction was 0.143 according to the Kappa agreement coefficient (P < 0.001). Moreover, regarding the predictive power, IWI had high sensitivity (95.6%), specificity (40%), positive and negative predictive values (90.5% and 60), positive and negative likelihood ratios (1.59 and 0.11), and accuracy (86.7%). Conclusion: The IWI as a more objective indicator has acceptable accuracy and power for predicting the 2-h SBT result. Therefore, in addition to the reliable prediction of the final weaning outcome, it has favorable power to predict if the patient is ready to breathe spontaneously as the first step to weaning. PMID:28904477
Gómez-Vallejo, V; Lekuona, A; Baz, Z; Szczupak, B; Cossío, U; Llop, J
2016-09-29
A simple, straightforward and efficient method for the synthesis of [ 18 F]CF 4 and [ 18 F]SF 6 based on an ion beam-induced isotopic exchange reaction is presented. Positron emission tomography ventilation studies in rodents using [ 18 F]CF 4 showed a uniform distribution of the radiofluorinated gas within the lungs and rapid elimination after discontinuation of the administration.
Continuous noninvasive ventilation delivered by a novel total face mask: a case series report.
Belchior, Inês; Gonçalves, Miguel R; Winck, João Carlos
2012-03-01
Noninvasive ventilation (NIV) has been widely used to decrease the complications associated with tracheal intubation in mechanically ventilated patients. However, nasal ulcerations may occur when conventional masks are used for continuous ventilation. A total face mask, which has no contact with the more sensitive areas of the face, is a possible option. We describe 3 patients with acute respiratory failure due to amyotrophic lateral sclerosis, who developed nasal bridge skin necrosis during continuous NIV, and one patient with post-extubation respiratory failure due to a high spinal cord injury, who had facial trauma with contraindication for conventional mask use. The total face mask was very well tolerated by all the patients, and permitted safe and efficient continuous NIV for several days until the acute respiratory failure episode resolved. None of the patients required endotracheal intubation during the acute episode.
A ventilation cooling shirt worn during office work in a hot climate: cool or not?
Zhao, Mengmeng; Kuklane, Kalev; Lundgren, Karin; Gao, Chuansi; Wang, Faming
2015-01-01
The aim of the study was to identify whether a ventilation cooling shirt was effective in reducing heat strain in a hot climate. Eight female volunteers were exposed to heat (38 °C, 45% relative humidity) for 2 h with simulated office work. In the first hour they were in normal summer clothes (total thermal insulation 0.8 clo); in the second hour a ventilation cooling shirt was worn on top. After the shirt was introduced for 1 h, the skin temperatures at the scapula and the chest were significantly reduced (p < 0.05). The mean skin and core temperatures were not reduced. The subjects felt cooler and more comfortable by wearing the shirt, but the cooling effect was most conspicuous only during the initial 10 min. The cooling efficiency of the ventilation shirt was not very effective under the low physical activity in this hot climate.
Tabernero Huguet, Eva; Gil Alaña, Pilar; Arana-Arri, Eunate; Citores Martín, Leyre; Alkiza Basañez, Ramon; Hernandez Gil, Anibal; Gil Molet, Alejandra
2016-01-01
Elderly patients with multiple morbidity and do not intubate (DNI) orders frequently present with acute respiratory failure. There are data supporting the effectiveness of non-invasive ventilation (NIV) in this context. Our chronic disease hospital developed an integrated care clinical pathway for the use of NIV in acute respiratory failure in the emergency room and wards in 2010. The aim of this study was to assess the outcome of NIV in patients with acute respiratory failure who had a DNI order in a sub-acute care hospital. Observational, one year-follow up study. The main variables were in-hospital mortality and one year mortality. Other variables recorded were: demographics, clinical data, functional data, performance of daily life activities, dementia, arterial blood gases and re-admissions. The study included a total of 102 patients, of which 22% were in institutions. The mean age 81±7.47% males, with a Charlson index 3.7±1, and Barthel index 54±31. The overall mortality during the admission was 33% (34 patients). Among those patients ventilated outside the protocol indication, the mortality was significantly greater, at 71% (P>.05). Overall one-year survival rate was 46%. This survival rate was statistically higher in patients with obesity hypoventilation syndrome and a Barthel >50. NIV is a useful technique in a hospital for chronic patients in an elderly population with a therapeutic ceiling. Despite their disease severity and comorbidity, acceptable survival rates are achieved. A correct case selection is needed. Obesity hypoventilation syndrome and those with Barthel index >50 have a better prognosis. Copyright © 2015 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.
Poor clinical outcomes among pneumonia patients with depressive disorder.
Kao, Li-Ting; Liu, Shih-Ping; Lin, Herng-Ching; Lee, Hsin-Chien; Tsai, Ming-Chieh; Chung, Shiu-Dong
2014-01-01
Some studies suggested that psychological stress may be associated with the severity and duration of infectious diseases. In this population-based study, we investigated associations between depressive disorder (DD) and pneumonia outcomes in Taiwan with a large-scale database from the National Health Insurance. Our study defined 112,198 patients who were hospitalized with a principal diagnosis of pneumonia. We defined their admission date for treatment of pneumonia as the index date. Subsequently, we selected 2,394 patients with DD within 3 years prior to their index date and 11,970 matched patients without DD. We carried out separate conditional logistic regressions to explore the association of clinical pneumonia treatment outcome (ICU admission, use of mechanical ventilation, acute respiratory failure and in-hospital death) with previously diagnosed DD. Patients with DD had a significantly higher probability of an intensive care unit admission (18.1% vs. 12.9%; p<0.001), need for mechanical ventilation (21.9% vs. 18.1%; p<0.001) and in-hospital death (10.4% vs. 9.0%; p = 0.025) than patients without DD. The study showed that pneumonia patients with DD were respectively 1.41- (95% CI: 1.25∼1.59, p<0.001), 1.28- (95% CI: 1.14∼1.43, p<0.001), and 1.17- times (95% CI: 1.01∼1.36, p = 0.039) greater odds of being admitted to the ICU, need for mechanical ventilation, and in-hospital death than patients without DD after adjusting for monthly income, urbanization level, geographic region and Charlson Comorbidity Index score. In conclusion, we found that pneumonia patients with DD were associated with poor treatment outcomes compared to patients without DD.
Energy-Efficient Renovation of Educational Buildings
ERIC Educational Resources Information Center
Erhorn-Kluttig, Heike; Morck, Ove
2005-01-01
Case studies demonstrating energy-efficient renovation of educational buildings collected by the International Energy Agency (IEA) provide information on retrofit technologies, energy-saving approaches and ventilation strategies. Some general findings are presented here along with one case study, Egebjerg School in Denmark, which shows how natural…
Electrical impedance tomography during major open upper abdominal surgery: a pilot-study
2014-01-01
Background Electrical impedance tomography (EIT) of the lungs facilitates visualization of ventilation distribution during mechanical ventilation. Its intraoperative use could provide the basis for individual optimization of ventilator settings, especially in patients at risk for ventilation-perfusion mismatch and impaired gas exchange, such as patients undergoing major open upper abdominal surgery. EIT throughout major open upper abdominal surgery could encounter difficulties in belt positioning and signal quality. Thus, we conducted a pilot-study and tested whether EIT is feasible in patients undergoing major open upper abdominal surgery. Methods Following institutional review board’s approval and written informed consent, we included patients scheduled for major open upper abdominal surgery of at least 3 hours duration. EIT measurements were conducted prior to intubation, at the time of skin incision, then hourly during surgery until shortly prior to extubation and after extubation. Number of successful intraoperative EIT measurements and reasons for failures were documented. From the valid measurements, a functional EIT image of changes in tidal impedance was generated for every time point. Regions of interest were defined as horizontal halves of the picture. Monitoring of ventilation distribution was assessed using the center of ventilation index, and also using the total and dorsal ventilated lung area. All parameter values prior to and post intubation as well as extubation were compared. A p < 0.05 was considered statistically significant. Results A total of 120 intraoperative EIT measurements during major abdominal surgery lasting 4-13 hours were planned in 14 patients. The electrode belt was attached between the 2nd and 4th intercostal space. Consecutive valid measurements could be acquired in 13 patients (93%). 111 intraoperative measurements could be retrieved as planned (93%). Main obstacle was the contact of skin electrodes. Despite the high belt position, distribution of tidal volume showed a significant shift of ventilation towards ventral lung regions after intubation. This was reversed after weaning from mechanical ventilation. Conclusions Despite a high belt position, monitoring of ventilation distribution is feasible in patients undergoing major open upper abdominal surgery lasting from 4 to 13 hours. Therefore, further interventional trials in order to optimize ventilatory management should be initiated. PMID:25018668
Mathai, Ss; Datta, Karuna; Adhikari, Km
2012-01-01
Nasal modes of respiratory support cause variable amounts of gastric dilatation which may increase gastro-oesophageal reflux (GER) in preterms. To compare the incidence of GER in nasally ventilated, preterm babies with controls (babies not on ventilation). A prospective, observational comparative study. Twenty-three preterm babies of gestational age 28-36 weeks and weight ranging between 1,000 g and < 2,500 g on either nasal continuous positive airway pressure (nCPAP) or nasal intermittent positive pressure venti-lation (nIPPV) were assessed for GER. They were compared with controls not on ventilation some of who were test babies when off ventilation (subgroup A) and some were unrelated babies not on ventilator but matched for gestational age and weight with test babies (subgroup B). All babies were subjected to continuous, oesophageal pH monitoring with dual sensor (upper and lower oesophageal) catheters. Reflux index (RI) was calculated as the percentage of study time the lower oesophageal pH was < 4. Primary outcome was the RI in the test and controls groups. Secondary outcome was the temporal relation of the reflux with symptoms if any. Numerical data were shown as mean with standard deviation and statistical comparisons were done using the χ(2)-test, Fischer test, and t-test wherever applicable. The RI was higher in ventilated babies as compared to the control group, particularly in the subgroup A, where test babies formed their own controls. Grade IV reflux (7 cases) was seen only in the ventilated babies. There was no difference in the incidence of GER in babies on nCPAP as compared with nIPPV. Grade IV reflux could not be reliably predicted by RI alone. No definite temporal relation between episodes of reflux and symptoms could be determined in this study. There is an increase in GER in preterms on nasal modes of ventilation. A combination of upper (pharyngeal) and lower oesophageal sensors are preferred to a single lower oesophageal sensor when assessing GER by oesophageal pHmetry in neonates.
International Space Station USOS Crew Quarters Ventilation and Acoustic Design Implementation
NASA Technical Reports Server (NTRS)
Broyan, James Lee, Jr.
2009-01-01
The International Space Station (ISS) United States Operational Segment (USOS) has four permanent rack sized ISS Crew Quarters (CQ) providing a private crewmember space. The CQ uses Node 2 cabin air for ventilation/thermal cooling, as opposed to conditioned ducted air from the ISS Temperature Humidity Control System or the ISS fluid cooling loop connections. Consequently, CQ can only increase the air flow rate to reduce the temperature delta between the cabin and the CQ interior. However, increasing airflow causes increased acoustic noise so efficient airflow distribution is an important design parameter. The CQ utilized a two fan push-pull configuration to ensure fresh air at the crewmember s head position and reduce acoustic exposure. The CQ interior needs to be below Noise Curve 40 (NC-40). The CQ ventilation ducts are open to the significantly louder Node 2 cabin aisle way which required significantly acoustic mitigation controls. The design implementation of the CQ ventilation system and acoustic mitigation are very inter-related and require consideration of crew comfort balanced with use of interior habitable volume, accommodation of fan failures, and possible crew uses that impact ventilation and acoustic performance. This paper illustrates the types of model analysis, assumptions, vehicle interactions, and trade-offs required for CQ ventilation and acoustics. Additionally, on-orbit ventilation system performance and initial crew feedback is presented. This approach is applicable to any private enclosed space that the crew will occupy.
Benefits of Manometer in Non-Invasive Ventilatory Support.
Lacerda, Rodrigo Silva; de Lima, Fernando Cesar Anastácio; Bastos, Leonardo Pereira; Fardin Vinco, Anderson; Schneider, Felipe Britto Azevedo; Luduvico Coelho, Yves; Fernandes, Heitor Gomes Costa; Bacalhau, João Marcus Ramos; Bermudes, Igor Matheus Simonelli; da Silva, Claudinei Ferreira; da Silva, Luiza Paterlini; Pezato, Rogério
2017-12-01
Introduction Effective ventilation during cardiopulmonary resuscitation (CPR) is essential to reduce morbidity and mortality rates in cardiac arrest. Hyperventilation during CPR reduces the efficiency of compressions and coronary perfusion. Problem How could ventilation in CPR be optimized? The objective of this study was to evaluate non-invasive ventilator support using different devices. The study compares the regularity and intensity of non-invasive ventilation during simulated, conventional CPR and ventilatory support using three distinct ventilation devices: a standard manual resuscitator, with and without airway pressure manometer, and an automatic transport ventilator. Student's t-test was used to evaluate statistical differences between groups. P values <.05 were regarded as significant. Peak inspiratory pressure during ventilatory support and CPR was significantly increased in the group with manual resuscitator without manometer when compared with the manual resuscitator with manometer support (MS) group or automatic ventilator (AV) group. The study recommends for ventilatory support the use of a manual resuscitator equipped with MS or AVs, due to the risk of reduction in coronary perfusion pressure and iatrogenic thoracic injury during hyperventilation found using manual resuscitator without manometer. Lacerda RS , de Lima FCA , Bastos LP , Vinco AF , Schneider FBA , Coelho YL , Fernandes HGC , Bacalhau JMR , Bermudes IMS , da Silva CF , da Silva LP , Pezato R . Benefits of manometer in non-invasive ventilatory support. Prehosp Disaster Med. 2017;32(6):615-620.
Racine, Stéphane X; Solis, Audrey; Hamou, Nora Ait; Letoumelin, Philippe; Hepner, David L; Beloucif, Sadek; Baillard, Christophe
2010-05-01
In edentulous patients, it may be difficult to perform face mask ventilation because of inadequate seal with air leaks. Our aim was to ascertain whether the "lower lip" face mask placement, as a new face mask ventilation method, is more effective at reducing air leaks than the standard face mask placement. Forty-nine edentulous patients with inadequate seal and air leak during two-hand positive-pressure ventilation using the ventilator circle system were prospectively evaluated. In the presence of air leaks, defined as a difference of at least 33% between inspired and expired tidal volumes, the mask was placed in a lower lip position by repositioning the caudal end of the mask above the lower lip while maintaining the head in extension. The results are expressed as mean +/- SD or median (25th-75th percentiles). Patient characteristics included age (71 +/- 11 yr) and body mass index (24 +/- 4 kg/m2). By using the standard method, the median inspired and expired tidal volumes were 450 ml (400-500 ml) and 0 ml (0-50 ml), respectively, and the median air leak was 400 ml (365-485 ml). After placing the mask in the lower lip position, the median expired tidal volume increased to 400 ml (380-490), and the median air leak decreased to 10 ml (0-20 ml) (P < 0.001 vs. standard method). The lower lip face mask placement with two hands reduced the air leak by 95% (80-100%). In edentulous patients with inadequate face mask ventilation, the lower lip face mask placement with two hands markedly reduced the air leak and improved ventilation.
Yadak, Mohammad; Ansari, Khalid Aziz; Qutub, Hatem; Al-Otaibi, Hajed; Al-Omar, Omar; Al-Onizi, Nawal; Farooqi, Faraz Ahmed
2017-09-30
Mechanical ventilation (MV) causes high level of stress in hospitalized patients. Weaning is the gradual process of decreasing ventilator support that in turn lead to termination of MV and increased respiratory effort, which may exacerbate symptoms and prolong MV. This study aimed to investigate the effect of listening to Holy Quran recitation (HQR) as a non-pharmacological intervention in patients during weaning from mechanical ventilation. This is a randomized controlled trial in which 55 patients admitted in the intensive care unit (ICU) and on mechanical ventilation were recruited. Patients were divided into experimental (case) and control group. In the experimental group, patients received 30 min of HQR, whereas in the control group, patients had 30 min of rest in bed before the start of the weaning. The physiological and/or clinical parameters of weaning were recorded. These parameters include rapid shallow breathing index, respiratory rate, heart rate, oxygen saturation, exhaled carbon dioxide, and blood pressure. The baseline demographic data for groups were presented in tables. The mean age was 54 ± 0.5 years for the experimental and 56.4 ± 18.5 years for the control groups. The physiological and clinical parameters were compared between case and control and found no significant difference. The preliminary findings of this pilot study suggest that there is no negative effect of HQR on weaning patients from mechanical ventilation in the ICU. The results also outline and explorthe possible utility of HQR further in ICU patients as an intervention in weaning patients off from ventilator in the ICU. Although there remains much to be done, our work generates important findings in the field of critical care management.
Increase in pulmonary blood flow at birth: role of oxygen and lung aeration.
Lang, Justin A R; Pearson, James T; Binder-Heschl, Corinna; Wallace, Megan J; Siew, Melissa L; Kitchen, Marcus J; te Pas, Arjan B; Fouras, Andreas; Lewis, Robert A; Polglase, Graeme R; Shirai, Mikiyasu; Hooper, Stuart B
2016-03-01
Lung aeration stimulates the increase in pulmonary blood flow (PBF) at birth, but the spatial relationships between PBF and lung aeration and the role of increased oxygenation remain unclear. Using simultaneous phase-contrast X-ray imaging and angiography, we have investigated the separate roles of lung aeration and increased oxygenation in PBF changes at birth using near-term (30 days of gestation) rabbit kits (n = 18). Rabbits were imaged before ventilation, then the right lung was ventilated with 100% nitrogen (N2), air or 100% O2 (oxygen), before all kits were switched to ventilation in air, followed by ventilation of both lungs using air. Unilateral ventilation of the right lung with 100% N2 significantly increased heart rate (from 69.4 ± 4.9 to 93.0 ± 15.0 bpm), the diameters of both left and right pulmonary axial arteries, number of visible vessels in both left and right lungs, relative PBF index in both pulmonary arteries, and reduced bolus transit time for both left and right axial arteries (from 1.34 ± 0.39 and 1.81 ± 0.43 s to 0.52 ± 0.17 and 0.89 ± 0.21 s in the left and right axial arteries, respectively). Similar changes were observed with 100% oxygen, but increases in visible vessel number and vessel diameter of the axial arteries were greater in the ventilated right lung during unilateral ventilation. These findings confirm that PBF increase at birth is not spatially related to lung aeration and that the increase in PBF to unventilated regions is unrelated to oxygenation, although oxygen can potentiate this increase. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.
Effect of exercise training on ventilatory efficiency in patients with heart disease: a review.
Prado, D M L; Rocco, E A; Silva, A G; Rocco, D F; Pacheco, M T; Furlan, V
2016-06-20
The analysis of ventilatory efficiency in cardiopulmonary exercise testing has proven useful for assessing the presence and severity of cardiorespiratory diseases. During exercise, efficient pulmonary gas exchange is characterized by uniform matching of lung ventilation with perfusion. By contrast, mismatching is marked by inefficient pulmonary gas exchange, requiring increased ventilation for a given CO2 production. The etiology of increased and inefficient ventilatory response to exercise in heart disease is multifactorial, involving both peripheral and central mechanisms. Exercise training has been recommended as non-pharmacological treatment for patients with different chronic cardiopulmonary diseases. In this respect, previous studies have reported improvements in ventilatory efficiency after aerobic exercise training in patients with heart disease. Against this background, the primary objective of the present review was to discuss the pathophysiological mechanisms involved in abnormal ventilatory response to exercise, with an emphasis on both patients with heart failure syndrome and coronary artery disease. Secondly, special focus was dedicated to the role of aerobic exercise training in improving indices of ventilatory efficiency among these patients, as well as to the underlying mechanisms involved.
NASA Astrophysics Data System (ADS)
Sohail, Maha
2017-12-01
A large proportion of the world's population resides in developing countries where there is a lack of rigorous studies in designing energy efficient buildings. This study is a step in designing a naturally ventilated high rise residential building in a tropical climatic context of the developing country, Pakistan. Karachi, the largest city of Pakistan, lies in the subtropical hot desert region with constant high temperature of average 32 °C throughout the summer and no particular winter season. The Design Builder software package is used to design a 25 storey high rise residential building relying primarily on natural ventilation. A final conceptual design is proposed after optimization of massing, geometry, orientation, and improved building envelope design including extensive shading devices in the form of trees. It has been observed that a reduction of 8 °C in indoor ambient temperature is possible to achieve with passive measures and use of night time ventilation. A fully naturally ventilated building can reduce the energy consumption for cooling and heating by 96 % compared to a building using air conditioning systems.
Bascompta, Marc; Castañón, Ana María; Sanmiquel, Lluís; Oliva, Josep
2016-11-01
Gases such as CO, CO2 or NOx are constantly generated by the equipment in any underground mine and the ventilation layout can play an important role in keeping low concentrations in the working faces. Hence, a method able to control the workplace environment is crucial. This paper proposes a geographical information system (GIS) for such goal. The system created provides the necessary tools to manage and analyse an underground environment, connecting pollutants and temperatures with the ventilation characteristics over time. Data concerning the ventilation system, in a case study, has been taken every month since 2009 and integrated into the management system, which has quantified the gasses concentration throughout the mine due to the characteristics and evolution of the ventilation layout. Three different zones concerning CO, CO2, NOx and effective temperature have been found as well as some variations among workplaces within the same zone that suggest local airflow recirculations. The system proposed could be a useful tool to improve the workplace conditions and efficiency levels. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cai, Hao; Long, Weiding; Li, Xianting; Kong, Lingjuan; Xiong, Shuang
2010-06-15
In case hazardous contaminants are suddenly released indoors, the prompt and proper emergency responses are critical to protect occupants. This paper aims to provide a framework for determining the optimal combination of ventilation and evacuation strategies by considering the uncertainty of source locations. The certainty of source locations is classified as complete certainty, incomplete certainty, and complete uncertainty to cover all the possible situations. According to this classification, three types of decision analysis models are presented. A new concept, efficiency factor of contaminant source (EFCS), is incorporated in these models to evaluate the payoffs of the ventilation and evacuation strategies. A procedure of decision-making based on these models is proposed and demonstrated by numerical studies of one hundred scenarios with ten ventilation modes, two evacuation modes, and five source locations. The results show that the models can be useful to direct the decision analysis of both the ventilation and evacuation strategies. In addition, the certainty of the source locations has an important effect on the outcomes of the decision-making. Copyright 2010 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poppiti, James; Nelson, Roger; MacMillan, Walter J.
The Waste Isolation Pilot Plant (WIPP) is a 655-meter deep mine near Carlsbad, New Mexico, used to dispose the nation’s defense transuranic waste. Limited airborne radioactivity was released from a container of radioactive waste in WIPP on 14 February, 2014. As designed, a mine ventilation filtration system prevented the large scale release of contamination from the underground. However, isolation dampers leaked, which allowed the release of low levels of contaminants after the event until they were sealed. None of the exposed individuals received any recordable dose. While surface contamination was limited, contamination in the ventilation system and portions of themore » underground was substantial. High efficiency particulate air (HEPA) filters in the operating ventilation system ensure continued containment during recovery and resumption of disposal operations. However, ventilation flow is restricted since the incident, with all exhaust air directed through the filters. Decontamination and natural fixation by the hygroscopic nature of the salt host rock has reduced the likelihood of further contamination spread. Contamination control and ventilation system operability are crucial for resumption of operations. This article provides an operational assessment and evaluation of these two key areas.« less
Kaub-Wittemer, Dagmar; Steinbüchel, Nicole von; Wasner, Maria; Laier-Groeneveld, Gerhard; Borasio, Gian Domenico
2003-10-01
Non-invasive ventilation (NIV) is an efficient palliative measure for symptoms of chronic hypoventilation in patients with amyotrophic lateral sclerosis (ALS), and can also lengthen survival. A subset of ALS patients undergoes tracheostomy ventilation (TV) for life prolongation. We investigated the quality of life (QOL) and psychosocial situation of 52 home ventilated ALS patients and their caregivers. The battery included sociodemographic, generic, and disease-specific variables, as well as the Profile of Mood States and the Munich Quality of Life Dimensions List. Data were compared between the NIV (n=32) and the TV (n=21) groups. Mean ventilation time was 14 months for NIV and 35 months for TV. Eighty-one percent of TV patients had been tracheotomized without informed consent. The data show a good overall QOL for both NIV and TV patients, but a very high burden of care for TV caregivers, 30% of whom rated their own QOL lower than their patient's QOL. Sexuality was an important issue. Thus, any assessment of QOL in a home palliative care situation should include the primary caregivers.
Assessment of distribution of ventilation by electrical impedance tomography in standing horses.
Ambrisko, T D; Schramel, J P; Adler, A; Kutasi, O; Makra, Z; Moens, Y P S
2016-02-01
The aim was to evaluate the feasibility of using electrical impedance tomography (EIT) in horses. Thoracic EIT was used in nine horses. Thoracic and abdominal circumference changes were also measured with respiratory ultrasound plethysmography (RUP). Data were recorded during baseline, rebreathing of CO2 and sedation. Three breaths were selected for analysis from each recording. During baseline breathing, horses regularly took single large breaths (sighs), which were also analysed. Functional EIT images were created using standard deviations (SD) of pixel signals and correlation coefficients (R) of each pixel signal with a reference respiratory signal. Left-to-right ratio, centre-of-ventilation and global-inhomogeneity-index were calculated. RM-ANOVA and Bonferroni tests were used (P < 0.05). Distribution of ventilation shifted towards right during sighs and towards dependent regions during sighs, rebreathing and sedation. Global-inhomogeneity-index did not change for SD but increased for R images during sedation. The sum of SDs for the respiratory EIT signals correlated well with thoracic (r(2) = 0.78) and abdominal (r(2) = 0.82) tidal circumferential changes. Inverse respiratory signals were identified on the images at sternal location and based on reviewing CT images, seemed to correspond to location of gas filled intestines. Application of EIT in standing non-sedated horses is feasible. EIT images may provide physiologically useful information even in situations, such as sighs, that cannot easily be tested by other methods.
Evaluation of a Shaker Dust Collector for Use in a Recirculating Ventilation System
Sawvel, Russell A.; Park, Jae Hong; Anthony, T. Renée
2016-01-01
General ventilation with recirculated air may be cost-effective to control the concentration of low-toxicity, contaminants in workplaces with diffuse, dusty operations, such as in agriculture. Such systems are, however, rarely adopted with little evidence showing improved air quality and ability to operate under harsh conditions. The goal of this work was to examine the initial and long-term performance of a fabric-filter shaker dust collector (SDC) in laboratory tests and as deployed within a recirculating ventilation system in an agricultural building. In laboratory tests, collection efficiency and pressure drop were tracked over several filter loading cycles, and the recovery of filter capacity (pressure drop) from filter shaking was examined. Collection efficiencies of particles larger than 5 μm was high (>95%) even when the filter was pristine, showing effective collection of large particles that dominate inhalable concentrations typical of agricultural dusts. For respirable-sized particles, collection efficiencies were low when the filter was pristine (e.g., 27% for 1 μm) but much higher when a dust cake developed on the filter (>99% for all size particles), even after shaking (e.g., 90% for 1 μm). The first shake of a filter was observed to recovery a substantial fraction of filter capacity, with subsequent shakes providing little benefit. In field tests, the SDC performed effectively over a period of three months in winter when incorporated in a recirculating ventilation system of a swine farrowing room. Trends in collection efficiency and pressure drop with loading were similar to those observed in the laboratory with overall collection efficiencies high (>80%) when pressure drop exceeded 230 Pa, or 23% of the maximum loading recommended by the manufacturer. This work shows that the SDC can function effectively over the harsh winter in swine rearing operations. Together with findings of improved air quality in the farrowing room reported in a companion manuscript, this article provides evidence that an SDC represents a cost-effective solution to improve air quality in agricultural settings. PMID:25955507
Nilius, Georg; Katamadze, Nato; Domanski, Ulrike; Schroeder, Maik; Franke, Karl-Josef
2017-01-01
COPD patients who develop chronic hypercapnic respiratory failure have a poor prognosis. Treatment of choice, especially the best form of ventilation, is not well known. This study compared the effects of pressure-controlled (spontaneous timed [ST]) non-invasive ventilation (NIV) and NIV with intelligent volume-assured pressure support (IVAPS) in chronic hypercapnic COPD patients regarding the effects on alveolar ventilation, adverse patient/ventilator interactions and sleep quality. This prospective, single-center, crossover study randomized patients to one night of NIV using ST then one night with the IVAPS function activated, or vice versa. Patients were monitored using polysomnography (PSG) and transcutaneous carbon dioxide pressure (PtcCO 2 ) measurement. Patients rated their subjective experience (total score, 0-45; lower scores indicate better acceptability). Fourteen patients were included (4 females, age 59.4±8.9 years). The total number of respiratory events was low, and similar under pressure-controlled (5.4±6.7) and IVAPS (8.3±10.2) conditions ( P =0.064). There were also no clinically relevant differences in PtcCO 2 between pressure-controlled and IVAPS NIV (52.9±6.2 versus 49.1±6.4 mmHg). Respiratory rate was lower under IVAPS overall; between-group differences reached statistical significance during wakefulness and non-rapid eye movement sleep. Ventilation pressures were 2.6 cmH 2 O higher under IVAPS versus pressure-controlled ventilation, resulting in a 20.1 mL increase in breathing volume. Sleep efficiency was slightly higher under pressure-controlled ventilation versus IVAPS. Respiratory arousals were uncommon (24.4/h [pressure-controlled] versus 25.4/h [IVAPS]). Overall patient assessment scores were similar, although there was a trend toward less discomfort during IVAPS. Our results show that IVAPS NIV allows application of higher nocturnal ventilation pressures versus ST without affecting sleep quality or inducing ventilation- associated events.
Chan, W R; Parthasarathy, S; Fisk, W J; McKone, T E
2016-04-01
We assessed the chronic health risks from inhalation exposure to volatile organic compounds (VOCs) and particulate matter (PM2.5) in U.S. offices, schools, grocery, and other retail stores and evaluated how chronic health risks were affected by changes in ventilation rates and air filtration efficiency. Representative concentrations of VOCs and PM2.5 were obtained from available data. Using a mass balance model, changes in exposure to VOCs and PM2.5 were predicted if ventilation rate were to increase or decrease by a factor of two, and if higher efficiency air filters were used. Indoor concentrations were compared to health guidelines to estimate percentage exceedances. The estimated chronic health risks associated with VOC and PM2.5 exposures in these buildings were low relative to the risks from exposures in homes. Chronic health risks were driven primarily by exposures to PM2.5 that were evaluated using disease incidence of mortality, chronic bronchitis, and non-fatal stroke. The leading cancer risk factor was exposure to formaldehyde. Using disability-adjusted life years (DALYs) to account for both cancer and non-cancer effects, results suggest that increasing ventilation alone is ineffective at reducing chronic health burdens. Other strategies, such as pollutant source control and the use of particle filtration, should also be considered. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Fan, Yuan-hua; Liu, Yuan-fei; Zhu, Hua-yong; Zhang, Min
2012-02-01
To evaluate effects of recruitment maneuver in prone position on hemodynamics in patients with severe pulmonary infection, based on the protective pulmonary ventilation strategy. Ninety-seven cases with severe pulmonary infection admitted to intensive care unit (ICU) of Ganzhou City People's Hospital undergoing mechanical ventilation were involved. Volume controlled ventilation mode with small tidal volume (8 ml/kg) and positive end-expiratory pressure (PEEP) of 6 cm H(2)O [1 cm H(2)O = 0.098 kPa] was conducted. Each patient underwent recruitment maneuver in supine position and then in prone position [PEEP 20 cm H(2)O+pressure control (PC) 20 cm H(2)O]. Heart rate (HR), mean arterial pressure (MAP), pulse oxygen saturation [SpO(2)] and blood gas analysis data were recorded before and after recruitment maneuver in either position. A double-lumen venous catheter was inserted into internal jugular vein or subclavian vein, and a pulse index contour cardiac output (PiCCO) catheter was introduced into femoral artery. Cardiac index (CI), stroke volume index (SVI), systemic vascular resistance index (SVRI), intra-thoracic blood volume index (ITBVI), extra vascular lung water index (EVLWI), global end-diastolic volume index (GEDVI), global ejection fraction (GEF), stroke volume variation (SVV) and central vein pressure (CVP) were monitored. (1) Compared with data before recruitment maneuver, there were no significant differences in HR and MAP after supine position and prone position recruitment maneuver, but significant differences in SpO(2) were found between before and after recruitment maneuver when patients' position was changed (supine position: 0.954 ± 0.032 vs. 0.917 ± 0.025, P < 0.05; prone position: 0.982 ± 0.028 vs. 0.936 ± 0.039, P < 0.05). SpO(2) was higher in prone position recruitment maneuver (P < 0.05). (2) Compared with data before recruitment maneuver, CI [L×min(-1)×m(-2)], SVI (ml/m(2)), GEDVI (ml/m(2)) and GEF were decreased significantly during recruitment maneuver (supine position: CI 3.2 ± 0.4 vs. 3.8 ± 0.6, SVI 32.4 ± 5.6 vs. 38.8 ± 6.5, GEDVI 689 ± 44 vs. 766 ± 32, GEF 0.267 ± 0.039 vs. 0.305 ± 0.056; prone position: CI 3.1 ± 0.5 vs. 3.6 ± 0.4, SVI 31.2 ± 5.8 vs. 37.3 ± 5.0, GEDVI 678 ± 41 vs. 758 ± 36, GEF 0.268 ± 0.040 vs. 0.288 ± 0.053, all P < 0.05), and CVP [cm H(2)O] and SVV were significantly increased [supine position: CVP 10.7 ± 1.5 vs. 8.2 ± 2.5, SVV (11.2 ± 3.3)% vs. (8.3 ± 4.7)%; prone position: CVP 10.3 ± 1.8 vs. 8.1 ± 2.5, SVV (12.7 ± 3.4)% vs. (9.1 ± 3.6)%, all P < 0.05], but they returned to the level of that before recruitment maneuver soon after termination of recruitment maneuver. There were no significant differences in SVRI, ITBVI and EVLWI between before and after recruitment maneuver in both positions. There were also no significant differences in above parameters between two positions. Based on the lung protective ventilation strategy of small tidal volume with PEEP, oxygenation was improved and SpO(2) was increased significantly when prone position ventilation combined with lung recruitment method was used in severe pulmonary infection patients. The effect of recruitment maneuver during prone position on hemodynamics was slight, except a temporary decrease of SVI and GEF just during recruitment maneuver.
Su, Mei; Huai, De; Cao, Juan; Ning, Ding; Xue, Rong; Xu, Meijie; Huang, Mao; Zhang, Xilong
2018-03-01
Although bilevel positive airway pressure (Bilevel PAP) therapy is usually used for overlap syndrome (OS), there is still a portion of OS patients in whom Bilevel PAP therapy could not simultaneously eliminate residual apnea events and hypercapnia. The current study was expected to explore whether auto-trilevel positive airway pressure (auto-trilevel PAP) therapy with auto-adjusting end expiratory positive airway pressure (EEPAP) can serve as a better alternative for these patients. From January of 2014 to June of 2016, 32 hypercapnic OS patients with stable chronic obstructive pulmonary diseases (COPD) and moderate-to-severe obstructive sleep apnea syndrome (OSAS) were recruited. Three variable modes of positive airway pressure (PAP) from the ventilator (Prisma25ST, Weinmann Inc., Germany) were applicated for 8 h per night. We performed the design of each mode at each night with an interval of two nights with no PAP treatment as a washout period among different modes. In Bilevel-1 mode (Bilevel-1), the expiratory positive airway pressure (EPAP) delivered from Bilevel PAP was always set as the lowest PAP for abolishment of snoring. For each patient, the inspiratory positive airway pressure (IPAP) was constantly set the same as the minimal pressure for keeping end-tidal CO 2 (ETCO 2 ) ≤45 mmHg for all three modes. However, the EPAP issued by Bilevel PAP in Bilevel-2 mode (Bilevel-2) was kept 3 cmH 2 O higher than that in Bilevel-1. In auto-trilevel mode (auto-trilevel) with auto-trilevel PAP, the initial part of EPAP was fixed at the same PAP as that in Bilevel-1 while the EEPAP was automatically regulated to rise at a range of ≤4 cmH 2 O based on nasal airflow wave changes. Comparisons were made for parameters before and during or following treatment as well as among different PAP therapy modes. The following parameters were compared such as nocturnal apnea hypopnea index (AHI), minimal SpO 2 (minSpO 2 ), arousal index, sleep structure and efficiency, morning PaCO 2 , and daytime Epworth Sleepiness Scale (ESS). Compared with the parameters before PAP therapies, during each mode of PAP treatment, significant reduction was detected in nocturnal AHI, arousal index, morning PaCO 2 , and daytime ESS while significant elevation was revealed in nocturnal minSpO 2 and sleep efficiency (all P < 0.01). Comparison among three PAP modes indicated that under the same IPAP, the auto-trilevel PAP mode could result in the lowest arousal index, daytime ESS, and the highest sleep efficiency. Compared with Bilevel-1, it was detected that (a) AHI was lower but minSpO 2 was higher in both Bilevel-2 and auto-trilevel (all P < 0.05) and (b) morning PaCO 2 showed no statistical difference from that in auto-trilevel but displayed higher in Bilevel-2 (P < 0.05). Compared with Bilevel-2, in auto-trilevel, both AHI and minSpO 2 showed no obvious changes (all P > 0.05) except with a lower morning PaCO 2 (P < 0.05). Auto-trilevel PAP therapy was superior over conventional Bilevel PAP therapy for hypercapnic OS patients with their OSAS moderate to severe, since auto-trilevel PAP was more efficacious in synchronous elimination of residual obstructive apnea events and CO 2 retention as well as in obtaining a better sleep quality and milder daytime drowsiness.
Lin, Jesun; Pai, Jar-Yuan; Chen, Chih-Cheng
2012-12-01
RFID technology, an automatic identification and data capture technology to provide identification, tracing, security and so on, was widely applied to healthcare industry in these years. Employing HEPA ventilation system in hospital is a way to ensure healthful indoor air quality to protect patients and healthcare workers against hospital-acquired infections. However, the system consumes lots of electricity which cost a lot. This study aims to apply the RFID technology to offer a unique medical staff and patient identification, and reacting HEPA air ventilation system in order to reduce the cost, save energy and prevent the prevalence of hospital-acquired infection. The system, reacting HEPA air ventilation system, contains RFID tags (for medical staffs and patients), sensor, and reacting system which receives the information regarding the number of medical staff and the status of the surgery, and controls the air volume of the HEPA air ventilation system accordingly. A pilot program was carried out in a unit of operation rooms of a medical center with 1,500 beds located in central Taiwan from Jan to Aug 2010. The results found the air ventilation system was able to function much more efficiently with less energy consumed. Furthermore, the indoor air quality could still keep qualified and hospital-acquired infection or other occupational diseases could be prevented.
Ventilation through a small-bore catheter: optimizing expiratory ventilation assistance.
Hamaekers, A E W; Borg, P A J; Götz, T; Enk, D
2011-03-01
Emergency ventilation through a small-bore transtracheal catheter can be lifesaving in a 'cannot intubate, cannot ventilate' situation. Ejectors, capable of creating suction by the Bernoulli principle, have been proposed to facilitate expiration through small-bore catheters. In this bench study, we compared a novel, purpose-built ventilation ejector (DE 5) with a previously proposed, modified industrial ejector (SBP 07). The generated insufflation pressures, suction pressures in static and dynamic situations, and also suction capacities and entrainment ratios of the SBP 07 and the DE 5 were determined. The DE 5 was also tested in a lung simulator with a simulated complete upper airway obstruction. Inspiratory and expiratory times through a transtracheal catheter were measured at various flow rates and achievable minute volumes were calculated. In a static situation, the SBP 07 showed a more negative pressure build-up compared with the DE 5. However, in a dynamic situation, the DE 5 generated a more negative pressure, resulting in a higher suction capacity. Employment of the DE 5 at a flow rate of 18 litre min(-1) allowed a minute volume through the transtracheal catheter of up to 8.27 litre min(-1) at a compliance of 100 ml cm H(2)O(-1). The efficiency of the DE 5 depended on the flow rate of the driving gas and the compliance of the lung simulator. In laboratory tests, the DE 5 is an optimized ventilation ejector suitable for applying expiratory ventilation assistance. Further research may confirm the clinical applicability as a portable emergency ventilator for use with small-bore catheters.
Panagopoulou, Niki; Karatzanos, Eleftherios; Dimopoulos, Stavros; Tasoulis, Athanasios; Tachliabouris, Ioannis; Vakrou, Styliani; Sideris, Antonios; Gratziou, Christina; Nanas, Serafim
2017-05-01
Background Exercise oscillatory ventilation in chronic heart failure has been suggested as a factor related to adverse cardiac events, aggravated prognosis and higher mortality. Exercise training is well known to affect exercise capacity and mechanisms of pathophysiology beneficially in chronic heart failure. Little is known, however, about the exercise training effects on characteristics of exercise oscillatory ventilation in chronic heart failure patients. Design and methods Twenty (out of 38) stable chronic heart failure patients exhibited exercise oscillatory ventilation (age 54 ± 11 years, peak oxygen uptake 15.0 ± 5.0 ml/kg per minute). Patients attended 36 sessions of high intensity interval exercise. All patients underwent cardiopulmonary exercise testing before and after the programme. Assessment of exercise oscillatory ventilation was based on the amplitude of cyclic fluctuations in breathing during rest and exercise. All values are mean ± SD. Results Exercise training reduced ( P < 0.05) the percentage of exercise oscillatory ventilation duration (79.0 ± 13.0 to 50.0 ± 25.0%), while average amplitude (5.2 ± 2.0 to 4.9 ± 1.6 L/minute) and length (44.0 ± 10.9 to 41.0 ± 6.7 seconds) did not change ( P > 0.05). Exercise oscillatory ventilation patients also increased exercise capacity ( P < 0.05). Conclusions A rehabilitation programme based on high intensity interval training improved exercise oscillatory ventilation observed in chronic heart failure patients, as well as cardiopulmonary efficiency and functional capacity.
Energy-Efficient Schools: Three Case Studies from Oregon.
ERIC Educational Resources Information Center
2003
This document presents case studies of three schools or districts in Oregon that have implemented steps to promote energy efficiency. Steps taken by the schools include daylighting, energy audits, special energy loans, new ventilation design, and sustainable building practices. The facilities described are Ash Creek Intermediate School in…
Kaczka, David W.; Herrmann, Jacob; Zonneveld, C. Elroy; Tingay, David G.; Lavizzari, Anna; Noble, Peter B.; Pillow, J. Jane
2015-01-01
Background Despite the theoretical benefits of high-frequency oscillatory ventilation (HFOV) in preterm infants, systematic reviews of randomized clinical trials do not confirm improved outcomes. We hypothesized that oscillating a premature lung with multiple frequencies simultaneously would improve gas exchange compared to traditional single-frequency oscillatory ventilation (SFOV). The goal of this study was to develop a novel method for HFOV, termed ‘multi-frequency oscillatory ventilation’ (MFOV), which relies on a broadband flow waveform more suitable for the heterogeneous mechanics of the immature lung. Methods Thirteen intubated preterm lambs were randomized to either SFOV or MFOV for 1 hour, followed by crossover to the alternative regimen for 1 hour. The SFOV waveform consisted of a pure sinusoidal flow at 5 Hz, while the customized MFOV waveform consisted of a 5 Hz fundamental with additional energy at 10 and 15 Hz. Per standardized protocol, mean pressure at airway opening (P̅ao) and inspired O2 fraction were adjusted as needed, and root mean square of the delivered oscillatory volume waveform (Vrms) was adjusted 15-minute intervals. A ventilatory cost function for SFOV and MFOV was defined as VC=(Vrms2PaCO2)Wt−1, where Wt denotes body weight. Results Averaged over all time points, MFOV resulted in significantly lower VC (246.9±6.0 vs. 363.5±15.9 mL2 mmHg kg−1) and P̅ao (12.8±0.3 vs. 14.1±0.5 cmH2O) compared to SFOV, suggesting more efficient gas exchange and enhanced lung recruitment at lower mean airway pressures. Conclusions Oscillation with simultaneous multiple frequencies may be a more efficient ventilator modality in premature lungs compared to traditional single-frequency HFOV. PMID:26495977
Pfleger, A; Steinbacher, M; Schwantzer, G; Weinhandl, E; Wagner, M; Eber, E
2015-09-01
Lung clearance index (LCI) is increasingly used as a study endpoint for therapeutic interventions in cystic fibrosis (CF) patients. We set out to assess the effect of chest physiotherapy on ventilation inhomogeneity in clinically stable patients with CF lung disease of varying severity. In 29 CF patients (7.3-43.7 years) N2MBW (nitrogen multiple breath washout), plethysmography, and spirometry measurements were conducted, followed by 30 min of supervised PEP mask chest physiotherapy and repeated measurements 30 min after therapy. We observed a mean change in LCI after physiotherapy from 15.00 to 14.80 (range, -4.84 to 3.37; p=0.578). In seven patients, LCI decreased, and in ten patients, LCI increased by ≥1. For the whole group, statistically significant improvements were seen in Reff, FEV1, FVC, and MEF50. By opening up previously poorly ventilated lung regions, physiotherapy may either increase or decrease ventilation inhomogeneity; the short-term effect of physiotherapy on LCI appears to be unpredictable. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Karayurt, Özgül; Akyol, Özay; Kılıçaslan, Necmiye; Akgün, Nuray; Sargın, Ümran; Kondakçı, Melike; Ekinci, Hanım; Sarı, Neslihan
2016-11-17
This study aimed to determine the incidence of pressure ulcers in patients on mechanical ventilation and selected risk factors likely to play a role in pressure ulcer development. The study included 110 patients recruited from an anesthesia critical care unit of a university hospital. Data were collected with a demographic and clinical characteristics form. The form was composed of questions about demographic characteristics and clinical features including diagnosis, duration of mechanical ventilation, general well-being, oxygenation, perfusion, and skin condition. The incidence of pressure ulcer was 15.5%. Duration of mechanical ventilation was longer and the body mass index was higher in patients developing pressure ulcers than in those without pressure ulcers. Additionally, 90.11% of patients with pressure ulcers had edema and 82.35% of patients with pressure ulcers received vasopressin. The patients with pressure ulcers had higher PH levels, lower PaO2 levels, higher PCO2 levels, lower SaO2 levels, and higher urine output. It can be recommended that nurses and other health professionals should be aware of factors playing a role in pressure ulcer development and should be able to conduct appropriate interventions to prevent pressure ulcers.
Jiang, Chuan; Esquinas, Antonio; Mina, Bushra
2017-01-01
A crucial step in the transition from mechanical ventilation to extubation is the successful performance of a spontaneous breathing trial (SBT). The American College of Chest Physicians (ACCP) Guidelines recommend removal of the endotracheal tube upon successful completion of a SBT. However, this does not guarantee successful extubation as there remains a risk of re-intubation. Guidelines have outlined ventilator liberation protocols, selected use of non-invasive ventilation on extubation, early mobilization, and dynamic ventilator metrics to prevent and better predict extubation failure. However, a significant percentage of patients still fail mechanical ventilation discontinuation. A common reason for re-intubation is having a weak cough strength, which reflects the inability to protect the airway. Evaluation of cough strength via objective measures using peak expiratory flow rate is a non-invasive and easily reproducible assessment which can predict extubation failure. We conducted a narrative review of the literature regarding use of cough strength as a predictive index for extubation failure risk. Results of our review show that cough strength, quantified objectively with a cough peak expiratory flow measurement (CPEF), is strongly associated with extubation success. Furthermore, various cutoff thresholds have been identified and can provide reasonable diagnostic accuracy and predictive power for extubation failure. These results demonstrate that measurement of the CPEF can be a useful tool to predict extubation failure in patients on MV who have passed a SBT. In addition, the data suggest that this diagnostic modality may reduce ICU length of stay, ICU expenditures, and morbidity and mortality.
Ainslie, B; Jackson, P L
2009-06-01
A means of determining air emission source regions adversely influencing the city of Prince George, British Columbia, Canada from potential burning of isolated piles of mountain pine beetle-killed lodge pole pine is presented. The analysis uses the CALPUFF atmospheric dispersion model to identify safe burning regions based on atmospheric stability and wind direction. Model results show that the location and extent of influence regions is sensitive to wind speed, wind direction, atmospheric stability and a threshold used to quantify excessive concentrations. A concentration threshold based on the Canada Wide PM(2.5) Standard is used to delineate the influence regions while Environment Canada's (EC) daily ventilation index (VI) is used to quantify local atmospheric stability. Results from the analysis, to be used by air quality meteorologists in assessing daily requests for burning permits, are presented as a series of maps delineating acceptable burning locations for sources placed at various distances from the city center and under different ventilation conditions. The results show that no burning should be allowed within 10 km of the city center; under poor ventilation conditions, no burning should be allowed within 20 km of the city center; under good ventilation conditions, burning can be allowed within 10-15 km of the city center; under good to fair ventilation conditions, burning can be allowed beyond 15 km of the city center; and if the wind direction can be reliably forecast, burning can be allowed between 5 and 10 km downwind of the city center under good ventilation conditions.
Prescott, Hallie C; Brower, Roy G; Cooke, Colin R; Phillips, Gary; O'Brien, James M
2013-03-01
Lung-protective ventilation with lower tidal volume and lower plateau pressure improves mortality in patients with acute lung injury and acute respiratory distress syndrome. We sought to determine the incidence of elevated plateau pressure in acute lung injury /acute respiratory distress syndrome patients receiving lower tidal volume ventilation and to determine the factors that predict elevated plateau pressure in these patients. We used data from 1398 participants in Acute Respiratory Distress Syndrome Network trials, who received lower tidal volume ventilation (≤ 6.5mL/kg predicted body weight). We considered patients with a plateau pressure greater than 30cm H2O and/or a tidal volume less than 5.5mL/kg predicted body weight on study day 1 to have "elevated plateau pressure." We used logistic regression to identify baseline clinical variables associated with elevated plateau pressure and to develop a model to predict elevated plateau pressure using a subset of 1,188 patients. We validated the model in the 210 patients not used for model development. Medical centers participating in Acute Respiratory Distress Syndrome Network clinical trials. None. Of the 1,398 patients in our study, 288 (20.6%) had elevated plateau pressure on day 1. Severity of illness indices and demographic factors (younger age, greater body mass index, and non-white race) were independently associated with elevated plateau pressure. The multivariable logistic regression model for predicting elevated plateau pressure had an area under the receiving operator characteristic curve of 0.71 for both the developmental and the validation subsets. acute lung injury patients receiving lower tidal volume ventilation often have a plateau pressure that exceeds Acute Respiratory Distress Syndrome Network goals. Race, body mass index, and severity of lung injury are each independently associated with elevated plateau pressure. Selecting a smaller initial tidal volume for non-white patients and patients with higher severity of illness may decrease the incidence of elevated plateau pressure. Prospective studies are needed to evaluate this approach.
Control of asthma triggers in indoor air with air cleaners: a modeling analysis.
Myatt, Theodore A; Minegishi, Taeko; Allen, Joseph G; Macintosh, David L
2008-08-06
Reducing exposure to environmental agents indoors shown to increase asthma symptoms or lead to asthma exacerbations is an important component of a strategy to manage asthma for individuals. Numerous investigations have demonstrated that portable air cleaning devices can reduce concentrations of asthma triggers in indoor air; however, their benefits for breathing problems have not always been reproducible. The potential exposure benefits of whole house high efficiency in-duct air cleaners for sensitive subpopulations have yet to be evaluated. We used an indoor air quality modeling system (CONTAM) developed by NIST to examine peak and time-integrated concentrations of common asthma triggers present in indoor air over a year as a function of natural ventilation, portable air cleaners, and forced air ventilation equipped with conventional and high efficiency filtration systems. Emission rates for asthma triggers were based on experimental studies published in the scientific literature. Forced air systems with high efficiency filtration were found to provide the best control of asthma triggers: 30-55% lower cat allergen levels, 90-99% lower risk of respiratory infection through the inhalation route of exposure, 90-98% lower environmental tobacco smoke (ETS) levels, and 50-75% lower fungal spore levels than the other ventilation/filtration systems considered. These results indicate that the use of high efficiency in-duct air cleaners provide an effective means of controlling allergen levels not only in a single room, like a portable air cleaner, but the whole house. These findings are useful for evaluating potential benefits of high efficiency in-duct filtration systems for controlling exposure to asthma triggers indoors and for the design of trials of environmental interventions intended to evaluate their utility in practice.
Control of asthma triggers in indoor air with air cleaners: a modeling analysis
Myatt, Theodore A; Minegishi, Taeko; Allen, Joseph G; MacIntosh, David L
2008-01-01
Background Reducing exposure to environmental agents indoors shown to increase asthma symptoms or lead to asthma exacerbations is an important component of a strategy to manage asthma for individuals. Numerous investigations have demonstrated that portable air cleaning devices can reduce concentrations of asthma triggers in indoor air; however, their benefits for breathing problems have not always been reproducible. The potential exposure benefits of whole house high efficiency in-duct air cleaners for sensitive subpopulations have yet to be evaluated. Methods We used an indoor air quality modeling system (CONTAM) developed by NIST to examine peak and time-integrated concentrations of common asthma triggers present in indoor air over a year as a function of natural ventilation, portable air cleaners, and forced air ventilation equipped with conventional and high efficiency filtration systems. Emission rates for asthma triggers were based on experimental studies published in the scientific literature. Results Forced air systems with high efficiency filtration were found to provide the best control of asthma triggers: 30–55% lower cat allergen levels, 90–99% lower risk of respiratory infection through the inhalation route of exposure, 90–98% lower environmental tobacco smoke (ETS) levels, and 50–75% lower fungal spore levels than the other ventilation/filtration systems considered. These results indicate that the use of high efficiency in-duct air cleaners provide an effective means of controlling allergen levels not only in a single room, like a portable air cleaner, but the whole house. Conclusion These findings are useful for evaluating potential benefits of high efficiency in-duct filtration systems for controlling exposure to asthma triggers indoors and for the design of trials of environmental interventions intended to evaluate their utility in practice. PMID:18684328
van Hooff, T; Blocken, B; van Heijst, G J F
2013-06-01
Accurate prediction of ventilation flow is of primary importance for designing a healthy, comfortable, and energy-efficient indoor environment. Since the 1970s, the use of computational fluid dynamics (CFD) has increased tremendously, and nowadays, it is one of the primary methods to assess ventilation flow in buildings. The most commonly used numerical approach consists of solving the steady Reynolds-averaged Navier-Stokes (RANS) equations with a turbulence model to provide closure. This article presents a detailed validation study of steady RANS for isothermal forced mixing ventilation of a cubical enclosure driven by a transitional wall jet. The validation is performed using particle image velocimetry (PIV) measurements for slot Reynolds numbers of 1000 and 2500. Results obtained with the renormalization group (RNG) k-ε model, a low-Reynolds k-ε model, the shear stress transport (SST) k-ω model, and a Reynolds stress model (RSM) are compared with detailed experimental data. In general, the RNG k-ε model shows the weakest performance, whereas the low-Re k-ε model shows the best agreement with the measurements. In addition, the influence of the turbulence model on the predicted air exchange efficiency in the cubical enclosure is analyzed, indicating differences up to 44% for this particular case. This article presents a detailed numerical study of isothermal forced mixing ventilation driven by a low-velocity (transitional) wall jet using steady computational fluid dynamics (CFD) simulations. It is shown that the numerically obtained room airflow patterns are highly dependent on the chosen turbulence model and large differences with experimentally obtained velocity fields can be present. The renormalization group (RNG) k-ε model, which is commonly used for room airflow modeling, shows the largest deviations from the measured velocities, indicating the care that must be taken when selecting a turbulence model for room airflow prediction. As a result of the different predictions of the flow pattern in the room, large differences are present between the predicted air exchange efficiency obtained with the four tested turbulence models, which can be as high as 44%. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.
Adaptive Servo-Ventilation for Central Sleep Apnea in Systolic Heart Failure.
Cowie, Martin R; Woehrle, Holger; Wegscheider, Karl; Angermann, Christiane; d'Ortho, Marie-Pia; Erdmann, Erland; Levy, Patrick; Simonds, Anita K; Somers, Virend K; Zannad, Faiez; Teschler, Helmut
2015-09-17
Central sleep apnea is associated with poor prognosis and death in patients with heart failure. Adaptive servo-ventilation is a therapy that uses a noninvasive ventilator to treat central sleep apnea by delivering servo-controlled inspiratory pressure support on top of expiratory positive airway pressure. We investigated the effects of adaptive servo-ventilation in patients who had heart failure with reduced ejection fraction and predominantly central sleep apnea. We randomly assigned 1325 patients with a left ventricular ejection fraction of 45% or less, an apnea-hypopnea index (AHI) of 15 or more events (occurrences of apnea or hypopnea) per hour, and a predominance of central events to receive guideline-based medical treatment with adaptive servo-ventilation or guideline-based medical treatment alone (control). The primary end point in the time-to-event analysis was the first event of death from any cause, lifesaving cardiovascular intervention (cardiac transplantation, implantation of a ventricular assist device, resuscitation after sudden cardiac arrest, or appropriate lifesaving shock), or unplanned hospitalization for worsening heart failure. In the adaptive servo-ventilation group, the mean AHI at 12 months was 6.6 events per hour. The incidence of the primary end point did not differ significantly between the adaptive servo-ventilation group and the control group (54.1% and 50.8%, respectively; hazard ratio, 1.13; 95% confidence interval [CI], 0.97 to 1.31; P=0.10). All-cause mortality and cardiovascular mortality were significantly higher in the adaptive servo-ventilation group than in the control group (hazard ratio for death from any cause, 1.28; 95% CI, 1.06 to 1.55; P=0.01; and hazard ratio for cardiovascular death, 1.34; 95% CI, 1.09 to 1.65; P=0.006). Adaptive servo-ventilation had no significant effect on the primary end point in patients who had heart failure with reduced ejection fraction and predominantly central sleep apnea, but all-cause and cardiovascular mortality were both increased with this therapy. (Funded by ResMed and others; SERVE-HF ClinicalTrials.gov number, NCT00733343.).
Zhang, Xianming; Wu, Weiliang; Zhu, Yongcheng; Jiang, Ying; Du, Juan; Chen, Rongchang
2016-01-01
It has proved that muscle paralysis was more protective for injured lung in severe acute respiratory distress syndrome (ARDS), but the precise mechanism is not clear. The purpose of this study was to test the hypothesis that abdominal muscle activity during mechanically ventilation increases lung injury in severe ARDS. Eighteen male Beagles were studied under mechanical ventilation with anesthesia. Severe ARDS was induced by repetitive oleic acid infusion. After lung injury, Beagles were randomly assigned into spontaneous breathing group (BIPAPSB) and abdominal muscle paralysis group (BIPAPAP). All groups were ventilated with BIPAP model for 8h, and the high pressure titrated to reached a tidal volume of 6ml/kg, the low pressure was set at 10 cmH2O, with I:E ratio 1:1, and respiratory rate adjusted to a PaCO2 of 35-60 mmHg. Six Beagles without ventilator support comprised the control group. Respiratory variables, end-expiratory volume (EELV) and gas exchange were assessed during mechanical ventilation. The levels of Interleukin (IL)-6, IL-8 in lung tissue and plasma were measured by qRT-PCR and ELISA respectively. Lung injury scores were determined at end of the experiment. For the comparable ventilator setting, as compared with BIPAPSB group, the BIPAPAP group presented higher EELV (427±47 vs. 366±38 ml) and oxygenation index (293±36 vs. 226±31 mmHg), lower levels of IL-6(216.6±48.0 vs. 297.5±71.2 pg/ml) and IL-8(246.8±78.2 vs. 357.5±69.3 pg/ml) in plasma, and lower express levels of IL-6 mRNA (15.0±3.8 vs. 21.2±3.7) and IL-8 mRNA (18.9±6.8 vs. 29.5±7.9) in lung tissues. In addition, less lung histopathology injury were revealed in the BIPAPAP group (22.5±2.0 vs. 25.2±2.1). Abdominal muscle activity during mechanically ventilation is one of the injurious factors in severe ARDS, so abdominal muscle paralysis might be an effective strategy to minimize ventilator-induce lung injury.
NASA Astrophysics Data System (ADS)
Lingwei, Kong; Lu, Wang; Rongwu, Mei; Yingyu, Tan; Yu, Zhang; Yan, Gao; Jianing, Sun; Ya, Li
2018-05-01
In this study, a new coupling process system of BFB (biological filter bed) and SFCW (subsurface-flow constructed wetland) based on the auto-ventilation network was proposed, and the comparative pollutant removal efficiency of the pilot test coupling system with different substrates configurations were investigated. The study found that: the influent concentration of the system fluctuated greatly and effluent concentration of the comparison system (b) was 20.22 ± 13.37 mg/L, 2.70 ± 2.49 mg/L, 4.40 ± 3.05 mg/L and 1.09 ± 0.62 mg/L, respectively. The comparison system (b) had better removal rates than that of the original system (a), which was 81.30 %, 90.28 %, 88.57 % and 75.36 % for CODcr, NH4 +-N, TN and TP, respectively. The removal of the above main water indexes of the comparison system (b) promoted to 4.20 %, 9.20 %, 7.66 % and 13.61 % respectively when compared to the original system (a), which showed that the optimized configuration of various kinds of substrates was significant and was more beneficial to the degradation and removal of pollutants. The adsorption and interception function of substrates in the constructed wetland was the main way of phosphorus removal. The function of auto-ventilation ensured the amount of DO in the coupling system, making the phosphorus removal was less affected comparing to structure of traditional wetland.
Vrijsen, Bart; Buyse, Bertien; Belge, Catharina; Robberecht, Wim; Van Damme, Philip; Decramer, Marc; Testelmans, Dries
2015-04-15
To evaluate the effects of noninvasive ventilation (NIV) on sleep in patients with amyotrophic lateral sclerosis (ALS) after meticulous titration with polysomnography (PSG). In this prospective observational study, 24 ALS patients were admitted to the sleep laboratory during 4 nights for in-hospital NIV titration with PSG and nocturnal capnography. Questionnaires were used to assess subjective sleep quality and quality of life (QoL). Patients were readmitted after one month. In the total group, slow wave sleep and REM sleep increased and the arousal-awakening index improved. The group without bulbar involvement (non-bulbar) showed the same improvements, together with an increase in sleep efficiency. Nocturnal oxygen and carbon dioxide levels improved in the total and non-bulbar group. Except for oxygen saturation during REM sleep, no improvement in respiratory function or sleep structure was found in bulbar patients. However, these patients showed less room for improvement. Patient-reported outcomes showed improvement in sleep quality and QoL for the total and non-bulbar group, while bulbar patients only reported improvements in very few subscores. This study shows an improvement of sleep architecture, carbon dioxide, and nocturnal oxygen saturation at the end of NIV titration and after one month of NIV in ALS patients. More studies are needed to identify the appropriate time to start NIV in bulbar patients. Our results suggest that accurate titration of NIV by PSG improves sleep quality. A commentary on this article appears in this issue on page 511. © 2015 American Academy of Sleep Medicine.
NASA Astrophysics Data System (ADS)
Badescu, Viorel; Landsberg, Peter T.; De Vos, Alexis; Desoete, Bart
2001-02-01
A detailed balance solar energy conversion model offering a single treatment of both photovoltaic and photothermal conversion is expounded. It includes a heat rejection mechanism. The effect of multiple impact ionizations on the solar cell efficiency is reconsidered by including the constraints dictated by the first law of thermodynamics (which already exist in the model) and it improves of course the solar cell efficiency. However the upper bound efficiencies previously derived are too optimistic as they do not take into consideration the necessary increase in solar cell temperature. The cell efficiency operating under unconcentrated radiation is a few percent lower than in the ideal case (i.e., with perfect cooling). Wider band gap materials are recommended for those applications where the cell cooling is not effective. The best operation of naturally ventilated cells is under unconcentrated or slightly concentrated solar radiation. Increasing the (forced) ventilation rate allows an increase of the optimum concentration ratio. Additional effects such as the radiation reflectance and radiative pair recombination efficiency are also considered. A sort of threshold minimum band gap depending on the last effect is emphasized: materials with band gaps narrower than this threshold are characterized by very low cell efficiency.
Energy Use Consequences of Ventilating a Net-Zero Energy House
Ng, Lisa C.; Payne, W. Vance
2016-01-01
A Net-Zero Energy Residential Test Facility (NZERTF) has been constructed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland to demonstrate that a home similar in size, aesthetics, and amenities to those in the surrounding communities can achieve net-zero energy use over the course of a year while meeting the average electricity and water use needs of a family of four in the United States. The facility incorporates renewable energy and energy efficient technologies, including an air-to-air heat pump system, a solar photovoltaic system, a solar thermal domestic hot water system, and a heat recovery ventilation system sized to meet American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) Standard 62.2-2010 ventilation requirements. The largest energy end use within the home was space conditioning, which included heat loss through the building envelope, ventilation air supplied by the heat recovery ventilator (HRV), and internal loads. While HRVs are often described as being able to save energy when compared to ventilating without heat recovery, there have been no studies using a full year of measured data that determine the thermal load and energy impacts of HRV-based ventilation on the central heating and cooling system. Over the course of a year, continuous operation of the HRV at the NZERTF resulted in an annual savings of 7 % in heat pump energy use compared with the hypothetical case of ventilating without heat recovery. The heat pump electrical use varied from an increase of 5 % in the cooling months to 36 % savings in the heating months compared with ventilation without heat recovery. The increase in the cooling months occurred when the outdoor temperature was lower than the indoor temperature, during which the availability of an economizer mode would have been beneficial. Nevertheless, the fan energy required to operate the selected HRV at the NZERTF paid for itself in the heat pump energy saved compared with ventilation without heat recovery. PMID:26903776
Energy Use Consequences of Ventilating a Net-Zero Energy House.
Ng, Lisa C; Payne, W Vance
2016-03-05
A Net-Zero Energy Residential Test Facility (NZERTF) has been constructed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland to demonstrate that a home similar in size, aesthetics, and amenities to those in the surrounding communities can achieve net-zero energy use over the course of a year while meeting the average electricity and water use needs of a family of four in the United States. The facility incorporates renewable energy and energy efficient technologies, including an air-to-air heat pump system, a solar photovoltaic system, a solar thermal domestic hot water system, and a heat recovery ventilation system sized to meet American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) Standard 62.2-2010 ventilation requirements. The largest energy end use within the home was space conditioning, which included heat loss through the building envelope, ventilation air supplied by the heat recovery ventilator (HRV), and internal loads. While HRVs are often described as being able to save energy when compared to ventilating without heat recovery, there have been no studies using a full year of measured data that determine the thermal load and energy impacts of HRV-based ventilation on the central heating and cooling system. Over the course of a year, continuous operation of the HRV at the NZERTF resulted in an annual savings of 7 % in heat pump energy use compared with the hypothetical case of ventilating without heat recovery. The heat pump electrical use varied from an increase of 5 % in the cooling months to 36 % savings in the heating months compared with ventilation without heat recovery. The increase in the cooling months occurred when the outdoor temperature was lower than the indoor temperature, during which the availability of an economizer mode would have been beneficial. Nevertheless, the fan energy required to operate the selected HRV at the NZERTF paid for itself in the heat pump energy saved compared with ventilation without heat recovery.
Lucato, Jeanette Janaina Jaber; Adams, Alexander Bernard; Souza, Rogério; Torquato, Jamili Anbar; Carvalho, Carlos Roberto Ribeiro; Marini, John J
2009-01-01
To evaluate and compare the efficiency of humidification in available heat and moisture exchanger models under conditions of varying tidal volume, respiratory rate, and flow rate. Inspired gases are routinely preconditioned by heat and moisture exchangers to provide a heat and water content similar to that provided normally by the nose and upper airways. The absolute humidity of air retrieved from and returned to the ventilated patient is an important measurable outcome of the heat and moisture exchangers' humidifying performance. Eight different heat and moisture exchangers were studied using a respiratory system analog. The system included a heated chamber (acrylic glass, maintained at 37 degrees C), a preserved swine lung, a hygrometer, circuitry and a ventilator. Humidity and temperature levels were measured using eight distinct interposed heat and moisture exchangers given different tidal volumes, respiratory frequencies and flow-rate conditions. Recovery of absolute humidity (%RAH) was calculated for each setting. Increasing tidal volumes led to a reduction in %RAH for all heat and moisture exchangers while no significant effect was demonstrated in the context of varying respiratory rate or inspiratory flow. Our data indicate that heat and moisture exchangers are more efficient when used with low tidal volume ventilation. The roles of flow and respiratory rate were of lesser importance, suggesting that their adjustment has a less significant effect on the performance of heat and moisture exchangers.
Zhao, Dan; Azimi, Parham; Stephens, Brent
2015-01-01
Much of human exposure to fine particulate matter (PM2.5) of outdoor origin occurs in residences. High-efficiency particle air filtration in central heating, ventilating, and air-conditioning (HVAC) systems is increasingly being used to reduce concentrations of particulate matter inside homes. However, questions remain about the effectiveness of filtration for reducing exposures to PM2.5 of outdoor origin and adverse health outcomes. Here we integrate epidemiology functions and mass balance modeling to estimate the long-term health and economic impacts of HVAC filtration for reducing premature mortality associated with indoor PM2.5 of outdoor origin in residences. We evaluate 11 classifications of filters (MERV 5 through HEPA) using six case studies of single-family home vintages and ventilation system combinations located in 22 U.S. cities. We estimate that widespread use of higher efficiency filters would reduce premature mortality by 0.002–2.5% and increase life expectancy by 0.02–1.6 months, yielding annual monetary benefits ranging from $1 to $1348 per person in the homes and locations modeled herein. Large differences in the magnitude of health and economic impacts are driven largely by differences in rated filter efficiency and building and ventilation system characteristics that govern particle infiltration and persistence, with smaller influences attributable to geographic location. PMID:26197328
Zhao, Dan; Azimi, Parham; Stephens, Brent
2015-07-21
Much of human exposure to fine particulate matter (PM2.5) of outdoor origin occurs in residences. High-efficiency particle air filtration in central heating, ventilating, and air-conditioning (HVAC) systems is increasingly being used to reduce concentrations of particulate matter inside homes. However, questions remain about the effectiveness of filtration for reducing exposures to PM2.5 of outdoor origin and adverse health outcomes. Here we integrate epidemiology functions and mass balance modeling to estimate the long-term health and economic impacts of HVAC filtration for reducing premature mortality associated with indoor PM2.5 of outdoor origin in residences. We evaluate 11 classifications of filters (MERV 5 through HEPA) using six case studies of single-family home vintages and ventilation system combinations located in 22 U.S. cities. We estimate that widespread use of higher efficiency filters would reduce premature mortality by 0.002-2.5% and increase life expectancy by 0.02-1.6 months, yielding annual monetary benefits ranging from $1 to $1348 per person in the homes and locations modeled herein. Large differences in the magnitude of health and economic impacts are driven largely by differences in rated filter efficiency and building and ventilation system characteristics that govern particle infiltration and persistence, with smaller influences attributable to geographic location.
Ding, Kai; Cao, Kunlin; Fuld, Matthew K.; Du, Kaifang; Christensen, Gary E.; Hoffman, Eric A.; Reinhardt, Joseph M.
2012-01-01
Purpose: Regional lung volume change as a function of lung inflation serves as an index of parenchymal and airway status as well as an index of regional ventilation and can be used to detect pathologic changes over time. In this paper, the authors propose a new regional measure of lung mechanics—the specific air volume change by corrected Jacobian. The authors compare this new measure, along with two existing registration based measures of lung ventilation, to a regional ventilation measurement derived from xenon-CT (Xe-CT) imaging. Methods: 4DCT and Xe-CT datasets from four adult sheep are used in this study. Nonlinear, 3D image registration is applied to register an image acquired near end inspiration to an image acquired near end expiration. Approximately 200 annotated anatomical points are used as landmarks to evaluate registration accuracy. Three different registration based measures of regional lung mechanics are derived and compared: the specific air volume change calculated from the Jacobian (SAJ); the specific air volume change calculated by the corrected Jacobian (SACJ); and the specific air volume change by intensity change (SAI). The authors show that the commonly used SAI measure can be derived from the direct SAJ measure by using the air-tissue mixture model and assuming there is no tissue volume change between the end inspiration and end expiration datasets. All three ventilation measures are evaluated by comparing to Xe-CT estimates of regional ventilation. Results: After registration, the mean registration error is on the order of 1 mm. For cubical regions of interest (ROIs) in cubes with size 20 mm × 20 mm × 20 mm, the SAJ and SACJ measures show significantly higher correlation (linear regression, average r2 = 0.75 and r2 = 0.82) with the Xe-CT based measure of specific ventilation (sV) than the SAI measure. For ROIs in slabs along the ventral-dorsal vertical direction with size of 150 mm × 8 mm × 40 mm, the SAJ, SACJ, and SAI all show high correlation (linear regression, average r2 = 0.88, r2 = 0.92, and r2 = 0.87) with the Xe-CT based sV without significant differences when comparing between the three methods. The authors demonstrate a linear relationship between the difference of specific air volume change and difference of tissue volume in all four animals (linear regression, average r2 = 0.86). Conclusions: Given a deformation field by an image registration algorithm, significant differences between the SAJ, SACJ, and SAI measures were found at a regional level compared to the Xe-CT sV in four sheep that were studied. The SACJ introduced here, provides better correlations with Xe-CT based sV than the SAJ and SAI measures, thus providing an improved surrogate for regional ventilation. PMID:22894434
VWPS: A Ventilator Weaning Prediction System with Artificial Intelligence
NASA Astrophysics Data System (ADS)
Chen, Austin H.; Chen, Guan-Ting
How to wean patients efficiently off mechanical ventilation continues to be a challenge for medical professionals. In this paper we have described a novel approach to the study of a ventilator weaning prediction system (VWPS). Firstly, we have developed and written three Artificial Neural Network (ANN) algorithms to predict a weaning successful rate based on the clinical data. Secondly, we have implemented two user-friendly weaning success rate prediction systems; the VWPS system and the BWAP system. Both systems could be used to help doctors objectively and effectively predict whether weaning is appropriate for patients based on the patients' clinical data. Our system utilizes the powerful processing abilities of MatLab. Thirdly, we have calculated the performance through measures such as sensitivity and accuracy for these three algorithms. The results show a very high sensitivity (around 80%) and accuracy (around 70%). To our knowledge, this is the first design approach of its kind to be used in the study of ventilator weaning success rate prediction.
Mechanical ventilation in patients with chronic obstructive pulmonary disease and bronchial asthma
Ahmed, Syed Moied; Athar, Manazir
2015-01-01
Chronic obstructive pulmonary disease (COPD) and bronchial asthma often complicate the surgical patients, leading to post-operative morbidity and mortality. Many authors have tried to predict post-operative pulmonary complications but not specifically in COPD. The aim of this review is to provide recent evidence-based guidelines regarding predictors and ventilatory strategies for mechanical ventilation in COPD and bronchial asthma patients. Using Google search for indexing databases, a search for articles published was performed using various combinations of the following search terms: ‘Predictors’; ‘mechanical ventilation’; COPD’; ‘COPD’; ‘bronchial asthma’; ‘recent strategies’. Additional sources were also identified by exploring the primary reference list. PMID:26556918
Adaptive servo-ventilation and deadspace: effects on central sleep apnoea.
Szollosi, I; O'Driscoll, D M; Dayer, M J; Coats, A J; Morrell, M J; Simonds, A K
2006-06-01
Central Sleep Apnoea (CSA) occurs commonly in heart failure. Adaptive servo-ventilation (ASV) and deadspace (DS) have been shown in research settings to reverse CSA. The likely mechanism for this is the increase of PaCO(2) above the apnoeic threshold. However the role of increasing FiCO(2) on arousability remains unclear. To compare the effects of ASV and DS on sleep and breathing, in particular effects on Arousal Index (ArI), ten male patients with heart failure and CSA were studied during three nights with polysomnography plus measurements of PetCO(2). The order of the interventions control (C), ASV and DS was randomized. ASV and DS caused similar reductions in apnoea-hypopnoea index [(C) 30.0 +/- 6.6, (ASV) 14.0 +/- 3.8, (DS) 15.9 +/- 4.7 e h(-1); both P < 0.05]. However, DS was associated with decreased total sleep time compared with C (P < 0.02) and increased spontaneous ArI compared to C and ASV (both P < 0.01). Only DS was associated with increased DeltaPetCO(2) from resting wakefulness to eupnic sleep [(C) 2.1 +/- 0.9, (ASV) 1.3 +/- 1.0, (DS) 5.6 +/- 0.5 mmHg; P = 0.01]. ASV and DS both stabilized ventilation however DS application also increased sleep fragmentation with negative impacts on sleep architecture. We speculate that this effect is likely to be mediated by increased PetCO(2) and respiratory effort associated with DS application.
Effects of Zolpidem CR on Sleep and Nocturnal Ventilation in Patients with Heart Failure
Gatti, Rodrigo C.; Burke, Patrick R.; Otuyama, Leonardo J.; Almeida, Dirceu R.; Tufik, Sergio; Poyares, Dalva
2016-01-01
Study Objective: This study aimed to evaluate the effects of zolpidem CR (controlled release) on sleep and nocturnal ventilation in patients with congestive heart failure, a population at risk for insomnia and poor sleep quality. Methods: Fifteen patients with heart failure (ischemic cardiomyopathy) and ejection fraction ≤ 45% in NYHA functional class I or II were evaluated with full polysomnography in a placebo-controlled, double-blind, randomized trial. Patients underwent three tests: (1) baseline polysomnography and, after randomization, (2) a new test with zolpidem CR 12.5 mg or placebo, and after 1 week, (3) a new polysomnography, crossing the “medication” used. Results: A 16% increase in total sleep time was found with the use of zolpidem CR and an increase in stage 3 NREM sleep (slow wave sleep). The apnea hypopnea index (AHI) did not change with zolpidem CR even after controlling for supine position; however, a slight but significant decrease was observed in lowest oxygen saturation compared with baseline and placebo conditions (83.60 ± 5.51; 84.43 ± 3.80; 80.71 ± 5.18, P = 0.002). Conclusion: Zolpidem CR improved sleep structure in patients with heart failure, did not change apnea hypopnea index, but slightly decreased lowest oxygen saturation. Citation: Gatti RC, Burke PR, Otuyama LJ, Almeida DR, Tufik S, Poyares D. Effects of zolpidem CR on sleep and nocturnal ventilation in patients with heart failure. SLEEP 2016;39(8):1501–1505. PMID:27166233
NASA Astrophysics Data System (ADS)
Jones, J. A.; Hoffman, R. B.; Buckland, D. A.; Harvey, C. M.; Bowen, C. K.; Hudy, C. E.; Strauss, S.; Novak, J.; Gernhardt, M. L.
Introduction: Onycholysis due to repetitive activity in the space suit glove during Neutral Buoyancy Laboratory (NBL) training and during spaceflight extravehicular activity (EVA) is a common observation. Moisture accumulates in gloves during EVA task performance and may contribute to the development of pain and damage to the fingernails experienced by many astronauts. The study evaluated the use of a long ventilation tube to determine if improved gas circulation into the hand area could reduce hand moisture and thereby decrease the associated symptoms. Methods: The current Extravehicular Mobility Unit (EMU) was configured with a ventilation tube that extended down a single arm of the crew member (E) and compared with the unventilated arm (C). Skin surface moisture was measured on both hands immediately after glove removal and a questionnaire administered to determine subjective measures. Astronauts ( n=6) were examined pre- and post-run. Results: There were consistent trends in the reduction of relative hydration ratios at dorsum ( C=3.34, E=2.11) and first ring finger joint ( C=2.46, E=1.96) when the ventilation tube was employed. Ventilation appeared more effective on the left versus the right hand, implying an interaction with hand anthropometry and glove fit. Symptom score was lower on the hand that had the long ventilation tube relative to the control hand in 2/6 EVA crew members. Conclusions: Increased ventilation to the hand was effective in reducing the risks of hand and nail discomfort symptoms from moderate to low in one-third of the subjects. Improved design in the ventilation capability of EVA spacesuits is expected to improve efficiency of air flow distribution.
Bench-test comparison of 26 emergency and transport ventilators.
L'Her, Erwan; Roy, Annie; Marjanovic, Nicolas
2014-10-15
Numerous emergency and transport ventilators are commercialized and new generations arise constantly. The aim of this study was to evaluate a large panel of ventilators to allow clinicians to choose a device, taking into account their specificities of use. This experimental bench-test took into account general characteristics and technical performances. Performances were assessed under different levels of FIO2 (100%, 50% or Air-Mix), respiratory mechanics (compliance 30,70,120 mL/cmH2O; resistance 5,10,20 cmH2O/mL/s), and levels of leaks (3.5 to 12.5 L/min), using a test lung. In total 26 emergency and transport ventilators were analyzed and classified into four categories (ICU-like, n = 5; Sophisticated, n = 10; Simple, n = 9; Mass-casualty and military, n = 2). Oxygen consumption (7.1 to 15.8 L/min at FIO2 100%) and the Air-Mix mode (FIO2 45 to 86%) differed from one device to the other. Triggering performance was heterogeneous, but several sophisticated ventilators depicted triggering capabilities as efficient as ICU-like ventilators. Pressurization was not adequate for all devices. At baseline, all the ventilators were able to synchronize, but with variations among respiratory conditions. Leak compensation in most ICU-like and 4/10 sophisticated devices was able to correct at least partially for system leaks, but with variations among ventilators. Major differences were observed between devices and categories, either in terms of general characteristics or technical reliability, across the spectrum of operation. Huge variability of tidal volume delivery with some devices in response to modifications in respiratory mechanics and FIO2 should make clinicians question their use in the clinical setting.
Optimization of Ventilation Energy Demands and Indoor Air Quality in High-Performance Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hun, Diana E; Jackson, Mark C; Shrestha, Som S
2014-01-01
High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. We attempted to bridge these two areas by conducting tests in a research house located in Oak Ridge, TN, that was 20 months old, energy-efficient (i.e., expected to consume 50% less energy than a house built per the 2006 IRC), tightly-built (i.e., natural ventilation rate ~0.02 h-1), unoccupied, and unfurnished. We identified air pollutants of concern in the test home that could generally serve as indicators of IAQ, and conduced field experiments and computer simulations to determine the effectiveness and energy required by various techniquesmore » that lessened the concentration of these contaminants. Formaldehyde was selected as the main pollutant of concern among the contaminants that were sampled in the initial survey because it was the only compound that showed concentrations that were greater than the recommended exposure levels. Field data indicate that concentrations were higher during the summer primarily because emissions from sources rise with increases in temperature. Furthermore, supply ventilation and gas-phase filtration were effective means to reduce formaldehyde concentrations; however, exhaust ventilation had minimal influence on this pollutant. Results from simulations suggest that formaldehyde concentrations obtained while ventilating per ASHRAE 62.2-2010 could be decreased by about 20% from May through September through three strategies: 1) increasing ASHRAE supply ventilation by a factor of two, 2) reducing the thermostat setpoint from 76 to 74 F, or 3) running a gas-phase filtration system while decreasing supply ventilation per ASHRAE by half. In the mixed-humid climate of Oak Ridge, these strategies caused increases in electricity cost of ~$5 to ~$15/month depending on outdoor conditions.« less
Design and Evaluation of a Ventilated Garment for Use in Temperatures up to 200°C
Crockford, G. W.; Hellon, R. F.
1964-01-01
The protection of personnel against high air and radiant temperatures is a problem that has been confronting industry for many years now, and for many industrial situations it still has not been solved. The experiments reported here were intended to determine the most suitable form of insulation for a hot entry suit for use primarily in furnace wrecking where mean radiant temperatures of 200°C. are met and where heat-reflecting garments are unsuitable due to the rapid deterioration of the reflecting surface. From a preliminary consideration of the problem it was concluded that a ventilated garment was required and that conventional ventilated garments in which air is induced to flow parallel to the body surfaces (axial ventilation) are basically unsound in design as the air is not utilized for the transfer of heat in the most efficient manner. A new form of ventilation was therefore developed in which air flows out through a permeable suit (radial ventilation). This form of ventilation produces what is called dynamic insulation, and this method of insulation, when compared with two alternative methods on a physical model, was found to be very effective. The model experiments were confirmed by comparative trials of three ventilated suits each using one of three different forms of insulation thought to be suitable for use in heat-protective clothing. Physiological measurements made on the subjects and physical measurement made on the suits confirmed that dynamic insulation is the most suitable insulation for a hot entry suit for furnace wrecking. With the air flows used in these experiments, dynamic insulation had a thermal conductance one-fifth that of conventional static insulation, and sweat losses and oral temperature rises were reduced by one-third and one-half respectively. PMID:14180476
Baarends, E M; Schols, A M; Nusmeier, C M; van der Grinten, C P; Wouters, E F
1998-05-01
Patients with chronic obstructive pulmonary disease (COPD) demonstrate an increased oxygen cost of breathing. It is as yet unclear whether this is related to a decreased breathing efficiency. The aim of the present study was to compare breathing efficiency in 16 patients with COPD (11 men, five women) and 16 healthy elderly subjects (seven men, nine women), and to investigate a possible relationship between breathing efficiency and resting energy expenditure (REE). REE was measured using a ventilated hood system. Breathing efficiency was assessed by measuring oxygen consumption (V'O2), mean inspiratory mouth pressure (MIP) and flow during breathing at rest and subsequently during breathing against an inspiratory threshold (40% of maximal inspiratory pressure). During loaded breathing there was a significant increase in V'O2, MIP, and external work of breathing compared with unloaded breathing in both groups. As intended, ventilation did not increase significantly during the breathing efficiency test in the patients with COPD. The breathing efficiency (median, range) of the patients with COPD was similar (3.7%, 1.4-8.7%) to that of the healthy elderly subjects (3.2%, 1.7-8.3%). Breathing efficiency was not correlated with REE in either group. In the present study, in which dynamic hyperinflation was probably prevented, no difference in breathing efficiency was found between healthy elderly subjects and COPD patients when breathing against an external inspiratory threshold. Furthermore, breathing efficiency was not related to REE in both groups.
Mayr, Ulrich; Karsten, Eugen; Lahmer, Tobias; Rasch, Sebastian; Thies, Philipp; Henschel, Benedikt; Fischer, Gerrit; Schmid, Roland M.
2018-01-01
Introduction Appropriate mechanical ventilation and prevention of alveolar collaps is mainly dependent on transpulmonary pressure TPP. TPP is assessed by measurement of esophageal pressure EP, largely influenced by pleural and intraabdominal pressure IAP. Consecutively, TPP-guided ventilation might be particularly useful in patients with high IAP. This study investigates the impact of large volume paracentesis LVP on TPP, EP, IAP as well as on hemodynamic and respiratory function in patients with liver cirrhosis and tense ascites. Material and methods We analysed 23 LVP-procedures in 11 cirrhotic patients ventilated with the AVEA Viasys respirator (CareFusion, USA) which is capable to measure EP via an esophageal tube. Results LVP of a mean volume of 4826±1276 mL of ascites resulted in marked increases in inspiratory (17.9±8.9 vs. 5.4±13.3 cmH2O; p<0.001) as well as expiratory TPP (-3.0±4.7 vs. -15.9±10.9 cmH2O; p<0.001; primary endpoint). In parallel, the inspiratory (2.4±8.7 vs. 14.1±14.5 cmH2O; p<0.001) and expiratory EP (12.4±6.0 vs. 24.9±11.3 cmH2O; p<0.001) significantly decreased. The effects were most pronounced for the release of the first 500 mL of ascites. LVP evoked substantial decreases in IAP and central venous pressure CVP. By contrast, mean arterial pressure, cardiac index, global end-diastolic volume index, extravascular lung water index and systemic vascular resistance index did not change. Among the respiratory parameters we observed an increase in paO2/FiO2 (247.7±60.9 vs. 208.3±46.8 mmHg; p<0.001) and a decrease in Oxygenation Index OI (4.8±2.0 vs. 5.8±3.1 cmH2O/mmHg; p = 0.002). Tidal volume (510±100 vs. 452±113 mL; p = 0.008) and dynamic respiratory system compliance Cdyn (46.8±15.9 vs. 35.1±14.6 mL/cmH20; p<0.001) increased, whereas paCO2 (47.3±10.7 vs. 51.2±12.3mmHg; p = 0.046) and the respiratory rate decreased (17.1±7.3 vs. 19.6±7.8 min-1; p = 0.010). Conclusions In mechanically ventilated patients with decompensated cirrhosis, intraabdominal hypertension resulted in a substantially decreased TPP despite PEEP-setting according to the ARDSNet. In these patients LVP markedly increased TPP and improved respiratory function in parallel with a decline of EP. Furthermore, LVP induced a decrease in IAP and CVP, while other hemodynamic parameters did not change. PMID:29538440
Bateman, Scot T; Borasino, Santiago; Asaro, Lisa A; Cheifetz, Ira M; Diane, Shelley; Wypij, David; Curley, Martha A Q
2016-03-01
The use of high-frequency oscillatory ventilation (HFOV) for acute respiratory failure in children is prevalent despite the lack of efficacy data. To compare the outcomes of patients with acute respiratory failure managed with HFOV within 24-48 hours of endotracheal intubation with those receiving conventional mechanical ventilation (CMV) and/or late HFOV. This is a secondary analysis of data from the RESTORE (Randomized Evaluation of Sedation Titration for Respiratory Failure) study, a prospective cluster randomized clinical trial conducted between 2009 and 2013 in 31 U.S. pediatric intensive care units. Propensity score analysis, including degree of hypoxia in the model, compared the duration of mechanical ventilation and mortality of patients treated with early HFOV matched with those treated with CMV/late HFOV. Among 2,449 subjects enrolled in RESTORE, 353 patients (14%) were ever supported on HFOV, of which 210 (59%) had HFOV initiated within 24-48 hours of intubation. The propensity score model predicting the probability of receiving early HFOV included 1,064 patients (181 early HFOV vs. 883 CMV/late HFOV) with significant hypoxia (oxygenation index ≥ 8). The degree of hypoxia was the most significant contributor to the propensity score model. After adjusting for risk category, early HFOV use was associated with a longer duration of mechanical ventilation (hazard ratio, 0.75; 95% confidence interval, 0.64-0.89; P = 0.001) but not with mortality (odds ratio, 1.28; 95% confidence interval, 0.92-1.79; P = 0.15) compared with CMV/late HFOV. In adjusted models including important oxygenation variables, early HFOV was associated with a longer duration of mechanical ventilation. These analyses make supporting the current approach to HFOV less convincing.
Bechard, Lori J.; Duggan, Christopher; Touger-Decker, Riva; Parrott, J. Scott; Rothpletz-Puglia, Pamela; Byham-Gray, Laura; Heyland, Daren; Mehta, Nilesh M.
2016-01-01
Objective To determine the influence of admission anthropometry on clinical outcomes in mechanically ventilated children in the pediatric intensive care unit (PICU). Design Data from 2 multicenter cohort studies were compiled to examine the unique contribution of nutritional status, defined by BMI Z-score, to 60-day mortality, hospital-acquired infections, length of hospital stay, and ventilator free days (VFD), using multivariate analysis. Setting 90 PICUs from 16 countries with 8 beds. Patients Children aged 1 month to 18 years, admitted to each participating PICU and requiring mechanical ventilation for more that 48 hours Measurements and Main Results Data from 1622 eligible patients, 54.8% male and mean (SD) age 4.5 (5.1) years, were analysed. Subjects were classified as underweight (17.9%), normal weight (54.2%), overweight (14.5%), and obese (13.4%) based on BMI Z-score at admission. After adjusting for severity of illness and site, the odds of 60-day mortality were higher in underweight (OR 1.53, P<0.001) children. The odds of hospital-acquired infections were higher in underweight (OR 1.88, P=0.008) and obese (OR 1.64, P<0.001) children. Hazard ratios for hospital discharge were lower among underweight (HR 0.71, P<0.001) and obese (HR 0.82, P=0.04) children. Underweight was associated with 1.3 (P=0.001) and 1.6 (P<0.001) fewer VFD, compared to normal weight and overweight, respectively. Conclusions Malnutrition is prevalent in mechanically ventilated children on admission to PICUs worldwide. Classification as underweight or obese was associated with higher risk of hospital-acquired infections and lower likelihood of hospital discharge. Underweight children had a higher risk of mortality and fewer ventilator-free days. PMID:26985636
Agodi, A; Auxilia, F; Barchitta, M; Cristina, M L; D'Alessandro, D; Mura, I; Nobile, M; Pasquarella, C
2015-07-01
Recent studies have shown a higher rate of surgical site infections in hip prosthesis implantation using unidirectional airflow ventilation compared with turbulent ventilation. However, these studies did not measure the air microbial quality of operating theatres (OTs), and assumed it to be compliant with the recommended standards for this ventilation technique. To evaluate airborne microbial contamination in OTs during hip and knee replacement surgery, and compare the findings with values recommended for joint replacement surgery. Air samplings were performed in 28 OTs supplied with unidirectional, turbulent and mixed airflow ventilation. Samples were collected using passive sampling to determine the index of microbial air contamination (IMA). Active sampling was also performed in some of the OTs. The average number of people in the OT and the number of door openings during the sampling period were recorded. In total, 1228 elective prosthesis procedures (60.1% hip and 39.9% knee) were included in this study. Of passive samplings performed during surgical activity in unidirectional airflow ventilation OTs (U-OTs) and mixed airflow OTs (M-OTs), 58.9% and 87.6% had IMA values >2, respectively. Of samplings performed during surgical activity in turbulent airflow OTs (T-OTs) and in turbulent airflow OTs with the surgical team wearing Steri-Shield Turbo Helmets (TH-OTs), 8.6% and 60% had IMA values ≤ 2, respectively. Positive correlation was found between IMA values and the number of people in the OT and the number of door openings (P < 0.001). In addition, correlation was found between active and passive sampling (P < 0.001). These findings challenge the belief that unidirectional systems always provide acceptable airborne bacterial counts. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Quantification and visualization of relative local ventilation on dynamic chest radiographs
NASA Astrophysics Data System (ADS)
Tanaka, Rie; Sanada, Shigeru; Okazaki, Nobuo; Kobayashi, Takeshi; Nakayama, Kazuya; Matsui, Takeshi; Hayashi, Norio; Matsui, Osamu
2006-03-01
Recently-developed dynamic flat-panel detector (FPD) with a large field of view is possible to obtain breathing chest radiographs, which provide respiratory kinetics information. This study was performed to investigate the ability of dynamic chest radiography using FPD to quantify relative ventilation according to respiratory physiology. We also reported the results of primary clinical study and described the possibility of clinical use of our method. Dynamic chest radiographs of 12 subjects involving abnormal subjects during respiration were obtained using a modified FPD system (30 frames in 10 seconds). Imaging was performed in three different positions (standing, and right and left decubitus positions) to change the distribution of local ventilation by changing the lung's own gravity in each area. The distance from the lung apex to the diaphragm (abbr. DLD) was measured by the edge detection technique for use as an index of respiratory phase. We measured pixel values in each lung area and calculated correlation coefficients with DLD. Differences in the pixel values between the maximum inspiratory and expiratory frame were calculated, and the trend of distribution was evaluated by two-way analysis of variance. Pixel value in each lung area was strongly associated with respiratory phase and its time variation and distribution were consistent with known properties in respiratory physiology. Dynamic chest radiography using FPD combined with our computerized methods was capable of quantifying relative amount of ventilation during respiration, and of detecting regional differences in ventilation. In the subjects with emphysema, areas with decreased respiratory changes in pixel value are consisted with the areas with air trapping. This method is expected to be a useful novel diagnostic imaging method for supporting diagnosis and follow-up of pulmonary disease, which presents with abnormalities in local ventilation.
Mason, David P; Thuita, Lucy; Nowicki, Edward R; Murthy, Sudish C; Pettersson, Gösta B; Blackstone, Eugene H
2010-03-01
The study objectives were to (1) compare survival after lung transplantation in patients requiring pretransplant mechanical ventilation or extracorporeal membrane oxygenation with that of patients not requiring mechanical support and (2) identify risk factors for mortality. Data were obtained from the United Network for Organ Sharing for lung transplantation from October 1987 to January 2008. A total of 15,934 primary transplants were performed: 586 in patients on mechanical ventilation and 51 in patients on extracorporeal membrane oxygenation. Differences between nonsupport patients and those on mechanical ventilation or extracorporeal membrane oxygenation support were expressed as 2 propensity scores for use in comparing risk-adjusted survival. Unadjusted survival at 1, 6, 12, and 24 months was 83%, 67%, 62%, and 57% for mechanical ventilation, respectively; 72%, 53%, 50%, and 45% for extracorporeal membrane oxygenation, respectively; and 93%, 85%, 79%, and 70% for unsupported patients, respectively (P < .0001). Recipients on mechanical ventilation were younger, had lower forced vital capacity, and had diagnoses other than emphysema. Recipients on extracorporeal membrane oxygenation were also younger, had higher body mass index, and had diagnoses other than cystic fibrosis/bronchiectasis. Once these variables, transplant year, and propensity for mechanical support were accounted for, survival remained worse after lung transplantation for patients on mechanical ventilation and extracorporeal membrane oxygenation. Although survival after lung transplantation is markedly worse when preoperative mechanical support is necessary, it is not dismal. Thus, additional risk factors for mortality should be considered when selecting patients for lung transplantation to maximize survival. Reduced survival for this high-risk population raises the important issue of balancing maximal individual patient survival against benefit to the maximum number of patients. Copyright 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Serpa Neto, Ary; Schmidt, Matthieu; Azevedo, Luciano C P; Bein, Thomas; Brochard, Laurent; Beutel, Gernot; Combes, Alain; Costa, Eduardo L V; Hodgson, Carol; Lindskov, Christian; Lubnow, Matthias; Lueck, Catherina; Michaels, Andrew J; Paiva, Jose-Artur; Park, Marcelo; Pesenti, Antonio; Pham, Tài; Quintel, Michael; Marco Ranieri, V; Ried, Michael; Roncon-Albuquerque, Roberto; Slutsky, Arthur S; Takeda, Shinhiro; Terragni, Pier Paolo; Vejen, Marie; Weber-Carstens, Steffen; Welte, Tobias; Gama de Abreu, Marcelo; Pelosi, Paolo; Schultz, Marcus J
2016-11-01
Extracorporeal membrane oxygenation (ECMO) is a rescue therapy for patients with acute respiratory distress syndrome (ARDS). The aim of this study was to evaluate associations between ventilatory settings during ECMO for refractory hypoxemia and outcome in ARDS patients. In this individual patient data meta-analysis of observational studies in adult ARDS patients receiving ECMO for refractory hypoxemia, a time-dependent frailty model was used to determine which ventilator settings in the first 3 days of ECMO had an independent association with in-hospital mortality. Nine studies including 545 patients were included. Initiation of ECMO was accompanied by significant decreases in tidal volume size, positive end-expiratory pressure (PEEP), plateau pressure, and driving pressure (plateau pressure - PEEP) levels, and respiratory rate and minute ventilation, and resulted in higher PaO 2 /FiO 2 , higher arterial pH and lower PaCO 2 levels. Higher age, male gender and lower body mass index were independently associated with mortality. Driving pressure was the only ventilatory parameter during ECMO that showed an independent association with in-hospital mortality [adjusted HR, 1.06 (95 % CI, 1.03-1.10)]. In this series of ARDS patients receiving ECMO for refractory hypoxemia, driving pressure during ECMO was the only ventilator setting that showed an independent association with in-hospital mortality.
Al Shehri, Abdullah M; El-Tahan, Mohamed R; Al Metwally, Roshdi; Qutub, Hatem; El Ghoneimy, Yasser F; Regal, Mohamed A; Zien, Haytham
2014-08-01
To test the effects of pressure-controlled (PCV) and volume-controlled (VCV) ventilation during one-lung ventilation (OLV) for thoracic surgery on right ventricular (RV) function. A prospective, randomized, double-blind, controlled, crossover study. A single university hospital. Fourteen pairs of consecutive patients scheduled for elective thoracotomy. Patients were assigned randomly to ventilate the dependent lung with PCV or VCV mode, each in a randomized crossover order using tidal volume of 6 mL/kg, I: E ratio 1: 2.5, positive end-expiratory pressure (PEEP) of 5 cm H2O and respiratory rate adjusted to maintain normocapnia. Intraoperative changes in RV function (systolic and early diastolic tricuspid annular velocity (TAV), end-systolic volume (ESV), end-diastolic volume (EDV) and fractional area changes (FAC)), airway pressures, compliance and oxygenation index were recorded. The use of PCV during OLV resulted in faster systolic (10.1±2.39 vs. 5.8±1.67 cm/s, respectively), diastolic TAV (9.2±1.99 vs. 4.6±1.42 cm/s, respectively) (p<0.001) and compliance and lower ESV, EDV and airway pressures (p<0.05) than during the use of VCV. Oxygenation indices were similar during the use of VCV and PCV. The use of PCV offers more improved RV function than the use of VCV during OLV for open thoracotomy. These results apply specifically to younger patients with good ventricular and pulmonary functions. © 2014 Elsevier Inc. All rights reserved.
Blankman, Paul; Hasan, Djo; van Mourik, Martijn S; Gommers, Diederik
2013-06-01
The purpose of this study was to compare the effect of varying levels of assist during pressure support (PSV) and Neurally Adjusted Ventilatory Assist (NAVA) on the aeration of the dependent and non-dependent lung regions by means of Electrical Impedance Tomography (EIT). We studied ten mechanically ventilated patients with Acute Lung Injury (ALI). Positive-End Expiratory Pressure (PEEP) and PSV levels were both 10 cm H₂O during the initial PSV step. Thereafter, we changed the inspiratory pressure to 15 and 5 cm H₂O during PSV. The electrical activity of the diaphragm (EAdi) during pressure support ten was used to define the initial NAVA gain (100 %). Thereafter, we changed NAVA gain to 150 and 50 %, respectively. After each step the assist level was switched back to PSV 10 cm H₂O or NAVA 100 % to get a new baseline. The EIT registration was performed continuously. Tidal impedance variation significantly decreased during descending PSV levels within patients, whereas not during NAVA. The dorsal-to-ventral impedance distribution, expressed according to the center of gravity index, was lower during PSV compared to NAVA. Ventilation contribution of the dependent lung region was equally in balance with the non-dependent lung region during PSV 5 cm H₂O, NAVA 50 and 100 %. Neurally Adjusted Ventilatory Assist ventilation had a beneficial effect on the ventilation of the dependent lung region and showed less over-assistance compared to PSV in patients with ALI.
112. ARAI Hot cell (ARA626) Building roof plan and details ...
112. ARA-I Hot cell (ARA-626) Building roof plan and details of roof ventilating equipment and parapet. Norman Engineering Company: 961-area/SF-626-A-2. Date: January 1959. Ineel index code no. 068-0626-00-613-102722. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
Hall, Graham L.; Logie, Karla M.; Parsons, Faith; Schulzke, Sven M.; Nolan, Gary; Murray, Conor; Ranganathan, Sarath; Robinson, Phil; Sly, Peter D.; Stick, Stephen M.
2011-01-01
Background In school-aged children with cystic fibrosis (CF) structural lung damage assessed using chest CT is associated with abnormal ventilation distribution. The primary objective of this analysis was to determine the relationships between ventilation distribution outcomes and the presence and extent of structural damage as assessed by chest CT in infants and young children with CF. Methods Data of infants and young children with CF diagnosed following newborn screening consecutively reviewed between August 2005 and December 2009 were analysed. Ventilation distribution (lung clearance index and the first and second moment ratios [LCI, M1/M0 and M2/M0, respectively]), chest CT and airway pathology from bronchoalveolar lavage were determined at diagnosis and then annually. The chest CT scans were evaluated for the presence or absence of bronchiectasis and air trapping. Results Matched lung function, chest CT and pathology outcomes were available in 49 infants (31 male) with bronchiectasis and air trapping present in 13 (27%) and 24 (49%) infants, respectively. The presence of bronchiectasis or air trapping was associated with increased M2/M0 but not LCI or M1/M0. There was a weak, but statistically significant association between the extent of air trapping and all ventilation distribution outcomes. Conclusion These findings suggest that in early CF lung disease there are weak associations between ventilation distribution and lung damage from chest CT. These finding are in contrast to those reported in older children. These findings suggest that assessments of LCI could not be used to replace a chest CT scan for the assessment of structural lung disease in the first two years of life. Further research in which both MBW and chest CT outcomes are obtained is required to assess the role of ventilation distribution in tracking the progression of lung damage in infants with CF. PMID:21886842
Zakharkina, Tetyana; Martin-Loeches, Ignacio; Matamoros, Sébastien; Povoa, Pedro; Torres, Antoni; Kastelijn, Janine B; Hofstra, Jorrit J; de Wever, B; de Jong, Menno; Schultz, Marcus J; Sterk, Peter J; Artigas, Antonio; Bos, Lieuwe D J
2017-09-01
Ventilator-associated pneumonia (VAP) is the most common nosocomial infections in patients admitted to the ICU. The adapted island model predicts several changes in the respiratory microbiome during intubation and mechanical ventilation. We hypothesised that mechanical ventilation and antibiotic administration decrease the diversity of the respiratory microbiome and that these changes are more profound in patients who develop VAP. Intubated and mechanically ventilated ICU-patients were included. Tracheal aspirates were obtained three times a week. 16S rRNA gene sequencing with the Roche 454 platform was used to measure the composition of the respiratory microbiome. Associations were tested with linear mixed model analysis and principal coordinate analysis. 111 tracheal aspirates were obtained from 35 patients; 11 had VAP, 18 did not have VAP. Six additional patients developed pneumonia within the first 48 hours after intubation. Duration of mechanical ventilation was associated with a decrease in α diversity (Shannon index; fixed-effect regression coefficient (β): -0.03 (95% CI -0.05 to -0.005)), but the administration of antibiotic therapy was not (fixed-effect β: 0.06; 95% CI -0.17 to 0.30). There was a significant difference in change of β diversity between patients who developed VAP and control patients for Bray-Curtis distances (p=0.03) and for Manhattan distances (p=0.04). Burkholderia, Bacillales and, to a lesser extent, Pseudomonadales positively correlated with the change in β diversity. Mechanical ventilation, but not antibiotic administration, was associated with changes in the respiratory microbiome. Dysbiosis of microbial communities in the respiratory tract was most profound in patients who developed VAP. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Fujii, Naoto; Tsuji, Bun; Honda, Yasushi; Kondo, Narihiko; Nishiyasu, Takeshi
2015-09-01
Hyperthermia induces hyperventilation and cerebral hypoperfusion in resting humans. We tested the hypothesis that short-term exercise-heat acclimation would alleviate those effects. Twenty healthy male subjects were divided into two groups that performed exercise training in the heat (TR-HEAT, n = 10) or cold (TR-COLD, n = 10). Before and after the training, the subjects in both groups participated in passive-heat tests at rest. Training was performed at 37°C (TR-HEAT) or 10°C (TR-COLD) and entailed four 20-min bouts of cycling at 50% peak oxygen uptake separated by 10-min recoveries daily for 6 consecutive days. After TR-HEAT, esophageal temperature was lowered when measured before and during passive heating, as was the esophageal temperature threshold for cutaneous active vasodilation, whereas plasma volume was increased (all P < 0.05). These traditional indices of successful heat acclimation were not all induced by TR-COLD (all P > 0.05). TR-HEAT had no significant effect on passive heating-induced increases in minute ventilation, even when evaluated as the esophageal temperature threshold for increases in minute ventilation and the slope relating minute ventilation to esophageal temperature (all P > 0.05). By contrast, TR-HEAT attenuated the passive heating-induced reduction in the cerebral vascular conductance index (middle cerebral artery mean blood velocity/mean arterial pressure) (all P < 0.05). TR-COLD did not attenuate the increase in minute ventilation or the decrease in the cerebral vascular conductance index observed during passive heating (all P > 0.05). These data suggest that in resting heated humans, short-term heat acclimation achieved through moderate-intensity exercise training (i.e., 50% peak oxygen uptake) in the heat does not influence hyperthermia-induced hyperventilation, but it does potentially attenuate cerebral hypoperfusion. Copyright © 2015 the American Physiological Society.
Miyake, Fuyu; Suga, Rika; Akiyama, Takahiro; Namba, Fumihiko
2018-04-06
Neonates, particularly premature babies, are often managed with endotracheal intubation and subsequent mechanical ventilation to maintain adequate pulmonary gas exchange. There is no consensus on the standard length of endotracheal tube. Although a short tube reduces resistance and respiratory dead space, it is believed to increase the risk of accidental extubation. There are not entirely coherent data regarding the effect of endotracheal tube length on work of breathing in infants. The aim of this study was to evaluate the impact of neonatal endotracheal tube diameter and length on the work of breathing using an infant in vitro lung model. We assessed the work of breathing index and mechanical ventilation settings with various endotracheal tube diameters and lengths using the JTR100 in vitro infant lung model. The basic parameters of the model were breathing frequency of 20 per minutes, inspiratory-expiratory ratio of 1:3, and positive end-expiratory pressure of 5 cmH 2 O. In addition, the diaphragm driving pressure to maintain the set tidal volume was measured as the work of breathing index. The JTR100 was connected to the Babylog 8000plus through the endotracheal tube. Finally, we monitored the peak inspiratory pressure generated during assist-control volume guarantee mode with a targeted tidal volume of 10-30 mL. The diaphragm driving pressure using a 2.0-mm inner diameter tube was twice as high as that using a 4.0-mm inner diameter tube. To maintain the targeted tidal volume, a shorter tube reduced both the diaphragm driving pressure and ventilator-generated peak inspiratory pressure. The difference in the generated peak inspiratory pressure between the shortest and longest tubes was 5 cmH 2 O. In our infant lung model, a shorter tube resulted in a lower work of breathing and lower ventilator-generated peak inspiratory pressure. © 2018 John Wiley & Sons Ltd.
International Space Station Crew Quarters Ventilation and Acoustic Design Implementation
NASA Technical Reports Server (NTRS)
Broyan, James L., Jr.; Cady, Scott M; Welsh, David A.
2010-01-01
The International Space Station (ISS) United States Operational Segment has four permanent rack sized ISS Crew Quarters (CQs) providing a private crew member space. The CQs use Node 2 cabin air for ventilation/thermal cooling, as opposed to conditioned ducted air-from the ISS Common Cabin Air Assembly (CCAA) or the ISS fluid cooling loop. Consequently, CQ can only increase the air flow rate to reduce the temperature delta between the cabin and the CQ interior. However, increasing airflow causes increased acoustic noise so efficient airflow distribution is an important design parameter. The CQ utilized a two fan push-pull configuration to ensure fresh air at the crew member's head position and reduce acoustic exposure. The CQ ventilation ducts are conduits to the louder Node 2 cabin aisle way which required significant acoustic mitigation controls. The CQ interior needs to be below noise criteria curve 40 (NC-40). The design implementation of the CQ ventilation system and acoustic mitigation are very inter-related and require consideration of crew comfort balanced with use of interior habitable volume, accommodation of fan failures, and possible crew uses that impact ventilation and acoustic performance. Each CQ required 13% of its total volume and approximately 6% of its total mass to reduce acoustic noise. This paper illustrates the types of model analysis, assumptions, vehicle interactions, and trade-offs required for CQ ventilation and acoustics. Additionally, on-orbit ventilation system performance and initial crew feedback is presented. This approach is applicable to any private enclosed space that the crew will occupy.
A perfluorochemical loss/restoration (L/R) system for tidal liquid ventilation.
Libros, R; Philips, C M; Wolfson, M R; Shaffer, T H
2000-01-01
Tidal liquid ventilation is the transport of dissolved respiratory gases via volume exchange of perfluorochemical (PFC) liquid to and from the PFC-filled lung. All gas-liquid surface tension is eliminated, increasing compliance and providing lung protection due to lower inflation pressures. Tidal liquid ventilation is achieved by cycling fluid from a reservoir to and from the lung by a ventilator. Current approaches are microprocessor-based with feedback control. During inspiration, warmed oxygenated PFC liquid is pumped from a fluid reservoir/gas exchanger into the lung. PFC fluid is conserved by condensing (60-80% efficiency) vapor in the expired gas. A feedback-control system was developed to automatically replace PFC lost due to condenser inefficiency. This loss/restoration (L/R) system consists of a PFC-vapor thermal detector (+/- 2.5%), pneumatics, amplifiers, a gas flow detector (+/- 1%), a PFC pump (+/- 5%), and a controller. Gravimetric studies of perflubron loss from a flask due to evaporation were compared with experimental L/R results and found to be within +/- 1.4%. In addition, when L/R studies were conducted with a previously reported liquid ventilation system over a four-hour period, the L/R system maintained system perflubron volume to within +/- 1% of prime volume and 11.5% of replacement volume, and the difference between experimental PFC loss and that of the L/R system was 1.8 mL/hr. These studies suggest that the PFC L/R system may have significant economic (appropriate dosing for PFC loss) as well as physiologic (maintenance of PFC inventory in the lungs and liquid ventilator) impact on liquid ventilation procedures.
Gruber, Elisabeth; Oberhammer, Rosmarie; Balkenhol, Karla; Strapazzon, Giacomo; Procter, Emily; Brugger, Hermann; Falk, Markus; Paal, Peter
2014-04-01
In some emergency situations resuscitation and ventilation may have to be performed by basic life support trained personnel, especially in rural areas where arrival of advanced life support teams can be delayed. The use of advanced airway devices such as endotracheal intubation has been deemphasized for basically-trained personnel, but it is unclear whether supraglottic airway devices are advisable over traditional mask-ventilation. In this prospective, randomized clinical single-centre trial we compared airway management and ventilation performed by nurses using facemask, laryngeal mask Supreme (LMA-S) and laryngeal tube suction-disposable (LTS-D). Basic life support trained nurses (n=20) received one-hour practical training with each device. ASA 1-2 patients scheduled for elective surgery were included (n=150). After induction of anaesthesia and neuromuscular block nurses had two 90-second attempts to manage the airway and ventilate the patient with volume-controlled ventilation. Ventilation failed in 34% of patients with facemask, 2% with LMA-S and 22% with LTS-D (P<0.001). In patients who could be ventilated successfully mean tidal volume was 240±210 ml with facemask, 470±120 ml with LMA-S and 470±140 ml with LTS-D (P<0.001). Leak pressure was lower with LMA-S (23.3±10.8 cm H2O, 95% CI 20.2-26.4) than with LTS-D (28.9±13.9 cm·H2O, 95% CI 24.4-33.4; P=0.047). After one hour of introductory training, nurses were able to use LMA-S more effectively than facemask and LTS-D. High ventilation failure rates with facemask and LTS-D may indicate that additional training is required to perform airway management adequately with these devices. High-level trials are needed to confirm these results in cardiac arrest patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Optimal Delivery of Aerosols to Infants During Mechanical Ventilation
Azimi, Mandana; Hindle, Michael
2014-01-01
Abstract Purpose: The objective of this study was to determine optimal aerosol delivery conditions for a full-term (3.6 kg) infant receiving invasive mechanical ventilation by evaluating the effects of aerosol particle size, a new wye connector, and timing of aerosol delivery. Methods: In vitro experiments used a vibrating mesh nebulizer and evaluated drug deposition fraction and emitted dose through ventilation circuits containing either a commercial (CM) or new streamlined (SL) wye connector and 3-mm endotracheal tube (ETT) for aerosols with mass median aerodynamic diameters of 880 nm, 1.78 μm, and 4.9 μm. The aerosol was released into the circuit either over the full inhalation cycle (T1 delivery) or over the first half of inhalation (T2 delivery). Validated computational fluid dynamics (CFD) simulations and whole-lung model predictions were used to assess lung deposition and exhaled dose during cyclic ventilation. Results: In vitro experiments at a steady-state tracheal flow rate of 5 L/min resulted in 80–90% transmission of the 880-nm and 1.78-μm aerosols from the ETT. Based on CFD simulations with cyclic ventilation, the SL wye design reduced depositional losses in the wye by a factor of approximately 2–4 and improved lung delivery efficiencies by a factor of approximately 2 compared with the CM device. Delivery of the aerosol over the first half of the inspiratory cycle (T2) reduced exhaled dose from the ventilation circuit by a factor of 4 compared with T1 delivery. Optimal lung deposition was achieved with the SL wye connector and T2 delivery, resulting in 45% and 60% lung deposition for optimal polydisperse (∼1.78 μm) and monodisperse (∼2.5 μm) particle sizes, respectively. Conclusions: Optimization of selected factors and use of a new SL wye connector can substantially increase the lung delivery efficiency of medical aerosols to infants from current values of <1–10% to a range of 45–60%. PMID:24299500
Branson, R D; Davis, K; Campbell, R S; Johnson, D J; Porembka, D T
1993-12-01
Determine the utility of a proposed algorithm in allowing safe, efficient humidification in mechanically ventilated patients using both a hygroscopic condenser humidifier (HCH) and heated humidifier (HH). A prospective study using an algorithm to chose humidification devices based on physical examination and sputum characteristics. All patients admitted to the surgical ICU. One hundred twenty consecutive patients requiring mechanical ventilation (MV) were studied. Patients were examined by the attending respiratory care practitioner and given either an HCH or HH. If patients demonstrated any of the following--thick or tenacious secretions, core temperature < 32 degrees C, or bloody secretions--they were given an HH. All others used an HCH. If any of the above conditions occurred during HCH use, the patient was given an HH. Duration of ventilation, incidence of nosocomial pneumonia, ventilator circuit colonization, and mortality were determined for patients in each group. Cost of humidification devices, number of suctioning procedures per day, and volume of saline solution instilled were also recorded. Initially, 27 percent (32/120) of patients used an HH and 73 percent (88/120) used an HCH. During the study, ten patients required changing to an HH during HCH use. Patients in the HH group were more likely to have preexisting lung disease and had a longer duration of ventilation (83 +/- 21 h) and higher mortality (21 percent). Patients in the HCH group were more likely to be postoperative, had shorter durations of ventilation (38 +/- 14 h), and lower mortality (9 percent). There was no difference in the incidence of nosocomial pneumonia between the two groups (9 percent vs 6 percent) and endotracheal tube occlusion did not occur in either group. Circuit colonization was common in the HH group (64 percent) but rate in the HCH group (5 percent). Cost per day was significantly less for the HCH group ($4 vs $19.80). Patients who required a change from HCH to HH did so at a mean of 5 days. The proposed algorithm resulted in cost-efficient and safe application of humidification devices in patients in the surgical ICU.
Fournel, Sébastien; Ouellet, Véronique; Charbonneau, Édith
2017-05-02
Heat stress negatively affects the health and performance of dairy cows, resulting in considerable economic losses for the industry. In future years, climate change will exacerbate these losses by making the climate warmer. Physical modification of the environment is considered to be the primary means of reducing adverse effects of hot weather conditions. At present, to reduce stressful heat exposure and to cool cows, dairy farms rely on shade screens and various forms of forced convection and evaporative cooling that may include fans and misters, feed-line sprinklers, and tunnel- or cross-ventilated buildings. However, these systems have been mainly tested in subtropical areas and thus their efficiency in humid continental climates, such as in the province of Québec, Canada, is unclear. Therefore, this study reviewed the available cooling applications and assessed their potential for northern regions. Thermal stress indices such as the temperature-humidity index (THI) were used to evaluate the different cooling strategies.
Progressive ventilation inhomogeneity in infants with cystic fibrosis after pulmonary infection.
Simpson, Shannon J; Ranganathan, Sarath; Park, Judy; Turkovic, Lidija; Robins-Browne, Roy M; Skoric, Billy; Ramsey, Kathryn A; Rosenow, Tim; Banton, Georgia L; Berry, Luke; Stick, Stephen M; Hall, Graham L
2015-12-01
Measures of ventilation distribution are promising for monitoring early lung disease in cystic fibrosis (CF). This study describes the cross-sectional and longitudinal impacts of pulmonary inflammation and infection on ventilation homogeneity in infants with CF.Infants diagnosed with CF underwent multiple breath washout (MBW) testing and bronchoalveolar lavage at three time points during the first 2 years of life.Measures were obtained for 108 infants on 156 occasions. Infants with a significant pulmonary infection at the time of MBW showed increases in lung clearance index (LCI) of 0.400 units (95% CI 0.150-0.648; p=0.002). The impact was long lasting, with previous pulmonary infection leading to increased ventilation inhomogeneity over time compared to those who remained free of infection (p<0.05). Infection with Haemophilus influenzae was particularly detrimental to the longitudinal lung function in young children with CF where LCI was increased by 1.069 units for each year of life (95% CI 0.484-1.612; p<0.001).Pulmonary infection during the first year of life is detrimental to later lung function. Therefore, strategies aimed at prevention, surveillance and eradication of pulmonary pathogens are paramount to preserve lung function in infants with CF. Copyright ©ERS 2015.
Morgan, Stephen; Hornik, Christoph P; Patel, Niyati; Williford, Walter L; Turner, David A; Cheifetz, Ira M
2016-11-01
Continuous high-frequency oscillation (CHFO) creates a pressure gradient in the small airways that accelerates expiratory flow. The intended use of CHFO therapy is to facilitate secretion removal and treat atelectasis. Our objective was to assess the feasibility, safety, and efficacy of CHFO in the mechanically ventilated pediatric population. After institutional review board approval, we retrospectively reviewed medical records of mechanically ventilated children treated with CHFO (the MetaNeb system) at our institution from July 1, 2007 through August 31, 2012. Patients supported with extracorporeal membrane oxygenation were excluded. We evaluated changes in ventilator settings in subjects with ventilator data documented within 6 h pre- and post-treatment. We evaluated arterial blood gas (ABG) results for individual treatments, comparing ABG results within 8 h pre-therapy to ABG results within 3 h post-treatment. Oxygen index and P aO 2 /F IO 2 were calculated. Demographic data, blood pressure, heart rate, and development of new air leak while being treated with CHFO were recorded. Pre- and post-CHFO measurements were compared using Wilcoxon signed-rank testing. Our cohort included 59 invasively ventilated subjects. Median age was 2 y (range 1 month to 19 y), and median weight was 14 kg (2-81 kg). We evaluated data on 528 total treatments (range per subject 1-39 treatments). Peak inspiratory pressure significantly decreased with CHFO, whereas other parameters, including P aCO 2 and breathing frequency, remained stable. There was no significant change in systolic blood pressure, diastolic blood pressure, or heart rate following treatment with CHFO. One subject (2%) developed a clinically insignificant pneumothorax during CHFO. CHFO is feasible and seems safe in our cohort of mechanically ventilated pediatric subjects. The rate of pneumothorax was consistent with that seen in similar pediatric ICU populations. These preliminary results suggest that CHFO may be beneficial by improving lung compliance in pediatric subjects with secretion-induced atelectasis. Prospective clinical studies are needed to further evaluate the clinical efficacy and safety of CHFO in children receiving invasive mechanical ventilation. Copyright © 2016 by Daedalus Enterprises.
Rondeau, Nelly; Cinotti, Raphaël; Rozec, Bertrand; Roquilly, Antoine; Floch, Hervé; Groleau, Nicolas; Michel, Patrick; Asehnoune, Karim; Blanloeil, Yvonnick
2012-10-01
Prevention of vasospasm is a challenging issue in subarachnoid hemorrhage (SAH) patients and the objective is to compare high dobutamine-induced cardiac index (CI) and high norepinephrine-induced hypertension for the prevention of vasospasm in SAH patients. Single center, single blind, controlled randomized study. Patients hospitalized in intensive care unit (ICU) for a moderate to severe SAH (WFNS grade ≥2) were randomized to receive dobutamine to reach a 25 % increase in cardiac index or norepinephrine to reach a mean arterial pressure ≥100 mmHg. Norepinephrine could be used in the dobutamine group to maintain a cerebral pressure perfusion ≥60 mmHg. Primary endpoint was the incidence of angiographic vasospasm in the first 14 days in the ICU setting, which was upheld by a cerebral arteriography. Secondary endpoints were the incidence of delayed ischemic deficits, duration of mechanical ventilation, and ICU length of stay (LOS). During the 3-year study, 41 patients were randomized. Six patients were excluded--3 because of consent withdrawal and 3 who did not receive the assigned treatment. Respectively, 17 and 18 patients in the dobutamine and the norepinephrine group were kept in analysis. Five (28 %) patients in the dobutamine group and 5 (27 %) patients in the norepinephrine group developed vasospasm in ICU (p = 1). Seven (41 %) patients presented a delayed ischemic deficit in the dobutamine group and 9 (50 %) in the norepinephrine group (p = 0.24). Duration of mechanical ventilation was 8 [0.5-11.5] days in the dobutamine group and 19 [2.7-23] days in the norepinephrine group (p = 0.01). ICU LOS was 11 [6-15] days in the dobutamine group and 21 [9-28] days in the norepinephrine group (p = 0.01). As compared to norepinephrine-induced hypertension, dobutamine-induced high CI did not reduce the rate of vasospasm in SAH patients. Dobutamine may reduce durations of mechanical ventilation and ICU LOS.
Li, Xiaojian; Zhong, Xiaomin; Deng, Zhongyuan; Zhang Xuhui; Zhang, Zhi; Zhang, Tao; Tang, Wenbin; Chen, Bib; Liu, Changling; Cao, Wenjuan
2014-08-01
To investigate the effects of lung protective ventilation strategy combined with lung recruitment maneuver on ARDS complicating patients with severe burn. Clinical data of 15 severely burned patients with ARDS admitted to our burn ICU from September 2011 to September 2013 and conforming to the study criteria were analyzed. Right after the diagnosis of acute lung injury/ARDS, patients received mechanical ventilation with lung protective ventilation strategy. When the oxygenation index (OI) was below or equal to 200 mmHg (1 mmHg = 0. 133 kPa), lung recruitment maneuver was performed combining incremental positive end-expiratory pressure. When OI was above 200 mmHg, lung recruitment maneuver was stopped and ventilation with lung protective ventilation strategy was continued. When OI was above 300 mmHg, mechanical ventilation was stopped. Before combining lung recruitment maneuver, 24 h after combining lung recruitment maneuver, and at the end of combining lung recruitment maneuver, variables of blood gas analysis (pH, PaO2, and PaCO2) were obtained by blood gas analyzer, and the OI values were calculated; hemodynamic parameters including heart rate, mean arterial pressure (MAP), central venous pressure (CVP) of all patients and the cardiac output (CO), extravascular lung water index (EVLWI) of 4 patients who received pulse contour cardiac output (PiCCO) monitoring were monitored. Treatment measures and outcome of patients were recorded. Data were processed with analysis of variance of repeated measurement of a single group and LSD test. (1) Before combining lung recruitment maneuver, 24 h after combining lung recruitment maneuver, and at the end of combining lung recruitment maneuver, the levels of PaO2 and OI of patients were respectively (77 ± 8), (113 ± 5), (142 ± 6) mmHg, and (128 ± 12), (188 ± 8), (237 ± 10) mmHg. As a whole, levels of PaO2 and OI changed significantly at different time points (with F values respectively 860. 96 and 842. 09, P values below 0. 01); levels of pH and PaCO2 showed no obvious changes (with F values respectively 0.35 and 3.13, P values above 0.05). (2) Levels of heart rate, MAP, CVP of all patients and CO of 4 patients who received PiCCO monitoring showed no significant changes at different time points (with F values from 0. 13 to 4. 26, P values above 0.05). Before combining lung recruitment maneuver, 24 h after combining lung recruitment maneuver, and at the end of combining lung recruitment maneuver, the EVLWI values of 4 patients who received PiCCO monitoring were respectively (13.5 ± 1.3), (10.2 ± 1.0), (7.0 ± 0.8) mL/kg ( F =117.00, P <0.01). (3) The patients received mechanical ventilation at 2 to 72 h after burn, lasting for 14-32 (21 ± 13) d. At post injury day 3-14 (7 ± 5) d, lung recruitment maneuver was applied for 2-5 (3.0 ± 2.0) d. All 15 patients recovered without other complications. Lung protective ventilation strategy combining lung recruitment maneuver can significantly improve the oxygenation in patients with severe burn complicated with ARDS and may therefore improve the prognosis.
10 CFR 431.171 - Purpose and scope. [Reserved
Code of Federal Regulations, 2011 CFR
2011-01-01
... Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Provisions for Commercial Heating, Ventilating, Air-Conditioning and Water Heating Products § 431.171 Purpose and scope. [Reserved] ...
Design New Buildings To Save Energy -- and Money
ERIC Educational Resources Information Center
Rittelmann, Richard
1974-01-01
Buildings should be designed so that energy systems function with maximum efficiency. Re-evaluation of standards for ventilation and lighting is recommended. Heat recovery techniques and topography can reduce heating loads. (MF)
Lucato, Jeanette Janaina Jaber; Adams, Alexander Bernard; Souza, Rogério; Torquato, Jamili Anbar; Carvalho, Carlos Roberto Ribeiro; Marini, John J
2009-01-01
OBJECTIVES: To evaluate and compare the efficiency of humidification in available heat and moisture exchanger models under conditions of varying tidal volume, respiratory rate, and flow rate. INTRODUCTION: Inspired gases are routinely preconditioned by heat and moisture exchangers to provide a heat and water content similar to that provided normally by the nose and upper airways. The absolute humidity of air retrieved from and returned to the ventilated patient is an important measurable outcome of the heat and moisture exchangers’ humidifying performance. METHODS: Eight different heat and moisture exchangers were studied using a respiratory system analog. The system included a heated chamber (acrylic glass, maintained at 37°C), a preserved swine lung, a hygrometer, circuitry and a ventilator. Humidity and temperature levels were measured using eight distinct interposed heat and moisture exchangers given different tidal volumes, respiratory frequencies and flow-rate conditions. Recovery of absolute humidity (%RAH) was calculated for each setting. RESULTS: Increasing tidal volumes led to a reduction in %RAH for all heat and moisture exchangers while no significant effect was demonstrated in the context of varying respiratory rate or inspiratory flow. CONCLUSIONS: Our data indicate that heat and moisture exchangers are more efficient when used with low tidal volume ventilation. The roles of flow and respiratory rate were of lesser importance, suggesting that their adjustment has a less significant effect on the performance of heat and moisture exchangers. PMID:19578664
Brown, Kathleen Ward; Minegishi, Taeko; Allen, Joseph G; McCarthy, John F; Spengler, John D; MacIntosh, David L
2014-08-01
Many interventions to reduce allergen levels in the home are recommended to asthma and allergy patients. One that is readily available and can be highly effective is the use of high performing filters in forced air ventilation systems. We conducted a modeling analysis of the effectiveness of filter-based interventions in the home to reduce airborne asthma and allergy triggers. This work used "each pass removal efficiency" applied to health-relevant size fractions of particles to assess filter performance. We assessed effectiveness for key allergy and asthma triggers based on applicable particle sizes for cat allergen, indoor and outdoor sources of particles <2.5 µm in diameter (PM2.5), and airborne influenza and rhinovirus. Our analysis finds that higher performing filters can have significant impacts on indoor particle pollutant levels. Filters with removal efficiencies of >70% for cat dander particles, fine particulate matter (PM2.5) and respiratory virus can lower concentrations of those asthma triggers and allergens in indoor air of the home by >50%. Very high removal efficiency filters, such as those rated a 16 on the nationally recognized Minimum Efficiency Removal Value (MERV) rating system, tend to be only marginally more effective than MERV12 or 13 rated filters. The results of this analysis indicate that use of a MERV12 or higher performing air filter in home ventilation systems can effectively reduce indoor levels of these common asthma and allergy triggers. These reductions in airborne allergens in turn may help reduce allergy and asthma symptoms, especially if employed in conjunction with other environmental management measures recommended for allergy and asthma patients.
Zhang, Xianming; Wu, Weiliang; Zhu, Yongcheng; Jiang, Ying; Du, Juan; Chen, Rongchang
2016-01-01
Objective It has proved that muscle paralysis was more protective for injured lung in severe acute respiratory distress syndrome (ARDS), but the precise mechanism is not clear. The purpose of this study was to test the hypothesis that abdominal muscle activity during mechanically ventilation increases lung injury in severe ARDS. Methods Eighteen male Beagles were studied under mechanical ventilation with anesthesia. Severe ARDS was induced by repetitive oleic acid infusion. After lung injury, Beagles were randomly assigned into spontaneous breathing group (BIPAPSB) and abdominal muscle paralysis group (BIPAPAP). All groups were ventilated with BIPAP model for 8h, and the high pressure titrated to reached a tidal volume of 6ml/kg, the low pressure was set at 10 cmH2O, with I:E ratio 1:1, and respiratory rate adjusted to a PaCO2 of 35–60 mmHg. Six Beagles without ventilator support comprised the control group. Respiratory variables, end-expiratory volume (EELV) and gas exchange were assessed during mechanical ventilation. The levels of Interleukin (IL)-6, IL-8 in lung tissue and plasma were measured by qRT-PCR and ELISA respectively. Lung injury scores were determined at end of the experiment. Results For the comparable ventilator setting, as compared with BIPAPSB group, the BIPAPAP group presented higher EELV (427±47 vs. 366±38 ml) and oxygenation index (293±36 vs. 226±31 mmHg), lower levels of IL-6(216.6±48.0 vs. 297.5±71.2 pg/ml) and IL-8(246.8±78.2 vs. 357.5±69.3 pg/ml) in plasma, and lower express levels of IL-6 mRNA (15.0±3.8 vs. 21.2±3.7) and IL-8 mRNA (18.9±6.8 vs. 29.5±7.9) in lung tissues. In addition, less lung histopathology injury were revealed in the BIPAPAP group (22.5±2.0 vs. 25.2±2.1). Conclusion Abdominal muscle activity during mechanically ventilation is one of the injurious factors in severe ARDS, so abdominal muscle paralysis might be an effective strategy to minimize ventilator-induce lung injury. PMID:26745868
Summer Thermal Performance of Ventilated Roofs with Tiled Coverings
NASA Astrophysics Data System (ADS)
Bortoloni, M.; Bottarelli, M.; Piva, S.
2017-01-01
The thermal performance of a ventilated pitched roof with tiled coverings is analysed and compared with unventilated roofs. The analysis is carried out by means of a finite element numerical code, by solving both the fluid and thermal problems in steady-state. A whole one-floor building with a pitched roof is schematized as a 2D computational domain including the air-permeability of tiled covering. Realistic data sets for wind, temperature and solar radiation are used to simulate summer conditions at different times of the day. The results demonstrate that the batten space in pitched roofs is an effective solution for reducing the solar heat gain in summer and thus for achieving better indoor comfort conditions. The efficiency of the ventilation is strictly linked to the external wind conditions and to buoyancy forces occurring due to the heating of the tiles.
Gonzalez-Bermejo, Jésus; Morelot-Panzini, Capucine; Arnol, Nathalie; Meininger, Vincent; Kraoua, Salah; Salachas, François; Similowski, Thomas
2013-09-01
Abstract NIV adherence ('quantity' of ventilation) has a prognostic impact in amyotrophic lateral sclerosis (ALS). We hypothesized that NIV effectiveness ('quality') could also have a similar impact. NIV effectiveness was evaluated in 82 patients within the first month (M1) and every three months (symptoms, arterial blood bases, and nocturnal pulsed oxygen saturation - SpO2). Kaplan-Meier survival and risk factors for mortality one year after NIV initiation were evaluated. Forty patients were considered 'correctly ventilated' at M1 (Group 1, less than 5% of nocturnal oximetry time with an SpO2<90% - TS90) while 42 were not (Group 2). Both groups were comparable in terms of respiratory and neurological baseline characteristics. Survival was better in Group 1 (75% survival at 12 months) than in Group 2 (43% survival at 12 months, p = 0.002). In 12 Group 2 patients corrective measures were efficient in correcting TS90 at six months. In this subgroup, one-year mortality was not different from that in Group 1. Multivariate analysis identified independent mortality risk factors expectedly including bulbar involvement (HR = 4.31 (1.73 - 10.76), p = 0.002), 'rapid respiratory decline' (HR = 3.55 (1.29 - 9.75), p = 0.014) and vital capacity (HR = 0.97 (0.95 - 0.99), p = 0.010), but also inadequate ventilation in the first month (HR = 2.32 (1.09 - 4.94), p = 0.029). In conclusion, in ALS patients NIV effectiveness to correct nocturnal desaturations is an independent prognostic factor.
Assouad, Jalal; Masmoudi, Hicham; Gonzalez-Bermejo, Jesus; Morélot-Panzini, Capucine; Diop, Moustapha; Grunenwald, Dominique; Similowski, Thomas
2012-08-01
Phrenic nerve stimulation for diaphragm pacing allows patients with central respiratory paralysis to be weaned from mechanical ventilation. Two procedures are available, either intrathoracic (bilateral thoracotomy) or intradiaphragmatic (four ports laparoscopy). The present experimental work assesses the feasibility, safety and efficacy of a trans-mediastinal implantation of intradiaphragmatic phenic nerve stimulation electrodes using a flexible gastroscope through a cervical incision. We operated on nine ewes. After selective bronchial intubation, we dissected the latero-tracheal space and opened both mediastinal pleura. We then introduced a flexible gastroscope into the pleural cavities, in a sequential manner. The phrenic nerves were located and followed up to the diaphragm dome. Electrodes loaded within a long, pliable needle were introduced through the adjacent intercostal space and implanted in each hemidiaphragm, at a 'tendinous' location (as close as possible to the entry of the nerve in the central tendon), and at a more lateral 'muscular' location. Postoperatively, the animals were ventilated using bilateral phrenic nerve stimulation. After euthanasia, abdominal verification of the electrodes position was performed through a laparotomy. The mediastinal and pleural parts of the procedure were uneventful. The insertion of electrodes was associated with transdiaphragmatic puncture and small abdominal haematomas in the first two animals studied. After a slight modification of the insertion technique, this was not observed anymore. Phrenic nerve stimulation produced efficient ventilation, with tidal volumes significantly higher when delivered at the tendinous site than at the muscular site. The trans-mediastinal implantation of intradiaphragmatic phrenic nerve stimulation electrodes is feasible, appears reasonably safe, and allows efficient ventilation.
Acute hemodynamic effects of adaptive servo-ventilation in patients with heart failure.
Yamada, Shiro; Sakakibara, Mamoru; Yokota, Takashi; Kamiya, Kiwamu; Asakawa, Naoya; Iwano, Hiroyuki; Yamada, Satoshi; Oba, Koji; Tsutsui, Hiroyuki
2013-01-01
Adaptive servo-ventilation (ASV) improves cardiac function in patients with heart failure (HF). We compared the hemodynamics of control and HF patients, and identified the predictors for acute effects of ASV in HF. We performed baseline echocardiographic measurements and hemodynamic measurements at baseline and after 15 min of ASV during cardiac catheterization in 11 control and 34 HF patients. Heart rate and blood pressure did not change after ASV in either the control or HF group. Stroke volume index (SVI) decreased from 49.3±7.6 to 41.3±7.6 ml/m2 in controls (P<0.0001) but did not change in the HF patients (from 34.8±11.5 to 32.8±8.9 ml/m2, P=0.148). In the univariate analysis, pulmonary capillary wedge pressure (PCWP), mitral regurgitation (MR)/left atrial (LA) area, E/A, E/e', and the sphericity index defined by the ratio between the short-axis and long-axis dimensions of the left ventricle significantly correlated with % change of SVI from baseline during ASV. PCWP and MR/LA area were independent predictors by multivariate analysis. Moreover, responders (15 of 34 HF patients; 44%) categorized by an increase in SVI showed significantly higher PCWP, MR, and sphericity index. Left ventricular structure and MR, as well as PCWP, could predict acute favorable effects on hemodynamics by ASV therapy in HF patients.
Optical intensity scintillation in the simulated atmospherical environment
NASA Astrophysics Data System (ADS)
Hajek, Lukas; Latal, Jan; Vanderka, Ales; Vitasek, Jan; Bojko, Marian; Bednarek, Lukas; Vasinek, Vladimir
2016-09-01
There are several parameters of the atmospheric environment which have an effect on the optical wireless connection. Effects like fog, snow or rain are ones of the effects which appears tendentiously and which are bound by season, geographic location, etc. One of the effects that appear with various intensity for the whole time is airflow. The airflow changes the local refractive index of the air and areas with lower or higher refractive index form. The light going through these areas refracts and due to the optical intensity scintillates on the detector of the receiver. The airflow forms on the basis of two effects in the atmosphere. The first is wind cut and flowing over barriers. The other is thermal flow when warm air rises to the higher layers of the atmosphere. The heart of this article is creation such an environment that will form airflow and the refractive index will scintillate. For the experiment, we used special laboratory box with high-speed ventilators and heating units to simulate atmospheric turbulence. We monitor the impact of ventilator arrangement and air temperature on the scintillation of the gas laser with wavelength 633 nm/15 mW. In the experiment, there is watched the difference in behavior between real measurement and flow simulation with the same peripheral conditions of the airflow in the area of 500 x 500 cm.
Investigation of Condensing Ice Heat Exchangers for MTSA Technology Development
NASA Technical Reports Server (NTRS)
Padilla, Sebastian; Powers, Aaron; Ball, Tyler; Lacomini, Christie; Paul, Heather L.
2009-01-01
Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal, carbon dioxide (CO2) and humidity control for a Portable Life Support Subsystem (PLSS). Metabolically-produced CO2 present in the ventilation gas of a PLSS is collected using a CO2-selective adsorbent via temperature swing adsorption. The temperature swing is initiated through cooling to well below metabolic temperatures. Cooling is achieved with a sublimation heat exchanger using water or liquid carbon dioxide (L CO2) expanded below sublimation temperature when exposed to low pressure or vacuum. Subsequent super heated vapor, as well as additional coolant, is used to further cool the astronaut. The temperature swing on the adsorbent is then completed by warming the adsorbent with a separate condensing ice heat exchanger (CIHX) using metabolic heat from moist ventilation gas. The condensed humidity in the ventilation gas is recycled at the habitat. The water condensation from the ventilation gas represents a significant source of potential energy for the warming of the adsorbent bed as it represents as much as half of the energy potential in the moist ventilation gas. Designing a heat exchanger to efficiently transfer this energy to the adsorbent bed and allow the collection of the water is a challenge since the CIHX will operate in a temperature range from 210K to 280K. The ventilation gas moisture will first freeze and then thaw, sometimes existing in three phases simultaneously.
Particle characterization in retail environments: concentrations, sources, and removal mechanisms.
Zaatari, M; Siegel, J
2014-08-01
Particles in retail environments can have consequences for the occupational exposures of retail workers and customers, as well as the energy costs associated with ventilation and filtration. Little is known about particle characteristics in retail environments. We measured indoor and outdoor mass concentrations of PM10 and PM2.5 , number concentrations of submicron particles (0.02-1 μm), size-resolved 0.3-10 μm particles, as well as ventilation rates in 14 retail stores during 24 site visits in Pennsylvania and Texas. Overall, the results were generally suggestive of relatively clean environments when compared to investigations of other building types and ambient/occupational regulatory limits. PM10 and PM2.5 concentrations (mean ± s.d.) were 20 ± 14 and 11 ± 10 μg/m(3), respectively, with indoor-to-outdoor ratios of 1.0 ± 0.7 and 0.88 ± 1.0. Mean submicron particle concentrations were 7220 ± 7500 particles/cm(3) with an indoor-to-outdoor ratio of 1.18 ± 1.30. The median contribution to PM10 and PM2.5 concentrations from indoor sources (vs. outdoors) was 83% and 53%, respectively. There were no significant correlations between measured ventilation rates and particle concentrations of any size. When examining options to lower PM2.5 concentrations below regulatory limits, the required changes to ventilation and filtration efficiency were site specific and depended on the indoor and outdoor concentration, emission rate, and infiltration level. Little is known about particle concentrations, contribution of indoor sources, and emission rates in retail environments. Knowledge of these particle characteristics informs health scientists with input parameters to include in exposure modeling. The predicted concentration change in response to different ventilation rates and filtration efficiencies may be used for guidance to develop control strategies to lower particulate matter concentrations in retail environments. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Verbrugge, S J; Vazquez de Anda, G; Gommers, D; Neggers, S J; Sorm, V; Böhm, S H; Lachmann, B
1998-08-01
Changes in pulmonary edema infiltration and surfactant after intermittent positive pressure ventilation with high peak inspiratory lung volumes have been well described. To further elucidate the role of surfactant changes, the authors tested the effect of different doses of exogenous surfactant preceding high peak inspiratory lung volumes on lung function and lung permeability. Five groups of Sprague-Dawley rats (n = 6 per group) were subjected to 20 min of high peak inspiratory lung volumes. Before high peak inspiratory lung volumes, four of these groups received intratracheal administration of saline or 50, 100, or 200 mg/kg body weight surfactant; one group received no intratracheal administration. Gas exchange was measured during mechanical ventilation. A sixth group served as nontreated, nonventilated controls. After death, all lungs were excised, and static pressure-volume curves and total lung volume at a transpulmonary pressure of 5 cm H2O were recorded. The Gruenwald index and the steepest part of the compliance curve (Cmax) were calculated. A bronchoalveolar lavage was performed; surfactant small and large aggregate total phosphorus and minimal surface tension were measured. In a second experiment in five groups of rats (n = 6 per group), lung permeability for Evans blue dye was measured. Before 20 min of high peak inspiratory lung volumes, three groups received intratracheal administration of 100, 200, or 400 mg/ kg body weight surfactant; one group received no intratracheal administration. A fifth group served as nontreated, nonventilated controls. Exogenous surfactant at a dose of 200 mg/kg preserved total lung volume at a pressure of 5 cm H2O, maximum compliance, the Gruenwald Index, and oxygenation after 20 min of mechanical ventilation. The most active surfactant was recovered in the group that received 200 mg/kg surfactant, and this dose reduced minimal surface tension of bronchoalveolar lavage to control values. Alveolar influx of Evans blue dye was reduced in the groups that received 200 and 400 mg/kg exogenous surfactant. Exogenous surfactant preceding high peak inspiratory lung volumes prevents impairment of oxygenation, lung mechanics, and minimal surface tension of bronchoalveolar lavage fluid and reduces alveolar influx of Evans blue dye. These data indicate that surfactant has a beneficial effect on ventilation-induced lung injury.
The long-term performance of electrically charged filters in a ventilation system.
Raynor, Peter C; Chae, Soo Jae
2004-07-01
The efficiency and pressure drop of filters made from polyolefin fibers carrying electrical charges were compared with efficiency and pressure drop for filters made from uncharged glass fibers to determine if the efficiency of the charged filters changed with use. Thirty glass fiber filters and 30 polyolefin fiber filters were placed in different, but nearly identical, air-handling units that supplied outside air to a large building. Using two kinds of real-time aerosol counting and sizing instruments, the efficiency of both sets of filters was measured repeatedly for more than 19 weeks while the air-handling units operated almost continuously. Pressure drop was recorded by the ventilation system's computer control. Measurements showed that the efficiency of the glass fiber filters remained almost constant with time. However, the charged polyolefin fiber filters exhibited large efficiency reductions with time before the efficiency began to increase again toward the end of the test. For particles 0.6 microm in diameter, the efficiency of the polyolefin fiber filters declined from 85% to 45% after 11 weeks before recovering to 65% at the end of the test. The pressure drops of the glass fiber filters increased by about 0.40 in. H2O, whereas the pressure drop of the polyolefin fiber filters increased by only 0.28 in. H2O. The results indicate that dust loading reduces the effectiveness of electrical charges on filter fibers. Copyright 2004 JOEH, LLC
Ng, Bing Feng; Xiong, Jin Wen; Wan, Man Pun
2017-01-01
The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM) indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop) that increases the energy consumption for air distribution. A pre-conditioning mechanism promoting the formation of particle clusters to enhance PM capturing efficiency without adding flow resistance in the air distribution ductwork could provide an energy-efficient solution. This pre-conditioning mechanism can be fulfilled by acoustic agglomeration, which is a phenomenon that promotes the coagulation of suspended particles by acoustic waves propagating in the fluid medium. This paper discusses the basic mechanisms of acoustic agglomeration along with influencing factors that could affect the agglomeration efficiency. The feasibility to apply acoustic agglomeration to improve filtration in air-conditioning and mechanical ventilation (ACMV) systems is investigated experimentally in a small-scale wind tunnel. Experimental results indicate that this novel application of acoustic pre-conditioning improves the PM2.5 filtration efficiency of the test filters by up to 10% without introducing additional pressure drop. The fan energy savings from not having to switch to a high capturing efficiency filter largely outstrip the additional energy consumed by the acoustics system. This, as a whole, demonstrates potential energy savings from the combined acoustic-enhanced filtration system without compromising on PM capturing efficiency.
Xiong, Jin Wen; Wan, Man Pun
2017-01-01
The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM) indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop) that increases the energy consumption for air distribution. A pre-conditioning mechanism promoting the formation of particle clusters to enhance PM capturing efficiency without adding flow resistance in the air distribution ductwork could provide an energy-efficient solution. This pre-conditioning mechanism can be fulfilled by acoustic agglomeration, which is a phenomenon that promotes the coagulation of suspended particles by acoustic waves propagating in the fluid medium. This paper discusses the basic mechanisms of acoustic agglomeration along with influencing factors that could affect the agglomeration efficiency. The feasibility to apply acoustic agglomeration to improve filtration in air-conditioning and mechanical ventilation (ACMV) systems is investigated experimentally in a small-scale wind tunnel. Experimental results indicate that this novel application of acoustic pre-conditioning improves the PM2.5 filtration efficiency of the test filters by up to 10% without introducing additional pressure drop. The fan energy savings from not having to switch to a high capturing efficiency filter largely outstrip the additional energy consumed by the acoustics system. This, as a whole, demonstrates potential energy savings from the combined acoustic-enhanced filtration system without compromising on PM capturing efficiency. PMID:28594862
Climate Change, Indoor Environment and Health
Climate change is becoming a driving force for improving energy efficiency because saving energy can help reduce the greenhouse gas emissions that contribute to climate change. However, it is important to balance energy saving measures with ventilation...
ERIC Educational Resources Information Center
Freeman, Laurie
1996-01-01
A new elementary school in New Hampshire uses innovative European ventilation technology to ensure excellent air quality. Combined with high-efficiency lighting, the system should reduce energy consumption by 10 to 20%, compared with a traditional facility. (MLF)
Bilgili, Beliz; Montoya, Juan C; Layon, A J; Berger, Andrea L; Kirchner, H L; Gupta, Leena K; Gloss, David S
2017-03-01
The ideal level of sedation in the ICU is an ongoing source of scrutiny. At higher levels of sedation, the current scoring systems are not ideal. BIS may be able to improve both. We evaluated literature on effectiveness of BIS monitoring in sedated mechanically ventilated (MV) ICU patients compared to clinical sedation scores (CSS). For this systematic review, full text articles were searched in OVID, MEDLINE, EMBASE, and Cochrane databases from 1986 - 2014. Additional studies were identified searching bibliographies/abstracts from national/international Critical Care Medicine conferences and references from searched articles retrieved. Search terms were: 'Clinical sedation scale, Bi-spectral Index, Mechanical ventilation, Intensive care Unit'. Included were prospective, randomized and non-randomized studies comparing BIS monitoring with any CSS in MV adult (>18 yr old) ICU patients. Studies were graded for quality of evidence based on bias as established by the GRADE guidelines. Additional sources of bias were examined. There were five studies which met inclusion criteria. All five studies were either unclear or high risk for blinding of participants and blinding of outcome assessment. All papers had at least one source of additional high risk, or unclear/unstated. BIS monitoring in the mechanically ventilated ICU patient may decrease sedative drug dose, recall, and time to wake-up. The studies suggesting this are severely limited methodologically. BIS, when compared to subjective CSSs, is not, at this time, clearly indicated. An appropriately powered randomized, controlled study is needed to determine if this monitoring modality is of use on the ICU.
Chen, Yen-Huey; Lin, Hui-Ling; Hsiao, Hsiu-Feng; Chou, Lan-Ti; Kao, Kuo-Chin; Huang, Chung-Chi; Tsai, Ying-Huang
2012-05-01
The functional status and outcomes in patients with prolonged mechanical ventilation (PMV) are often limited by poor endurance and pulmonary mechanics, which result from the primary diseases or prolonged time bedridden. We evaluate the impact of exercise training on pulmonary mechanics, physical functional status, and hospitalization outcomes in PMV patients. Twenty-seven subjects with PMV in our respiratory care center (RCC) were divided randomly into an exercise training group (n = 12) and a control group (n = 15). The exercise program comprised 10 sessions of exercise training. The measurement of pulmonary mechanics and physical functional status (Functional Independence Measurement and Barthel index) were performed pre-study and post-study. The hospitalization outcomes included: days of mechanical ventilation, hospitalization days, and weaning and mortality rates during RCC stay. The training group had significant improvement in tidal volume (143.6 mL vs 192.5 mL, P = .02) and rapid shallow breathing index after training (162.2 vs 110.6, P = .009). No significant change was found in the control group except respiratory rate. Both groups had significant improvement in functional status during the study. However, the training group had greater changes in FIM score than the control group (44.6 vs 34.2, P = .024). The training group also had shorter RCC stay and higher weaning and survival rates than the control group, although no statistical difference was found. Subjects with PMV in our RCC demonstrated significant improvement in pulmonary mechanics and functional status after exercise training. The application of exercise training may be helpful for PMV patients to improve hospitalization outcomes.
Refeeding syndrome: a potentially fatal condition but remains underdiagnosed and undertreated.
Gariballa, Salah
2008-06-01
To describe two cases of successfully prevented refeeding syndrome in a high-risk group of patients. Case 1 was a 70-y-old woman who presented with a 4-mo history of poor dietary intake and ill health due to a connective tissue disease leading to myositis and dysphagia and complicated by respiratory failure needing mechanical ventilation. Twelve hours after starting nasogastric tube feeding, she developed a cardiac arrest from which she was successfully resuscitated. Repeated attempts to wean her from the ventilator failed. Case 2 was a 15-y-old girl who was readmitted after a total colectomy for severe ulcerative colitis with diarrhea and vomiting leading to significant weight loss. Her body mass index was 11.4 kg/m(2). In case 1, after consultation by the clinical nutrition team, the diagnosis of refeeding syndrome was made and the patient was duly started on a high-protein, high-fat, low-carbohydrate diet, multivitamin and trace-element supplements, and electrolyte infusion. Subsequently she was successfully weaned from the ventilator. In case 2, further investigation by the clinical nutrition team revealed low baseline electrolyte concentrations including potassium, magnesium, calcium, and phosphate and low serum albumin. Her low body mass index and baseline electrolyte concentrations put her at high risk of developing refeeding syndrome. She was initially started on low-calorie feeding, multivitamin and minerals, and her electrolytes were carefully monitored. She made a good recovery. Refeeding syndrome is a life-threatening, underdiagnosed, treatable condition but there is a need for a wider awareness of the condition among health professionals.
Attali, Valérie; Straus, Christian; Pottier, Michel; Buzare, Marie-Annick; Morélot-Panzini, Capucine; Arnulf, Isabelle; Similowski, Thomas
2017-01-23
The purpose of this study was to describe the sleep structure (especially slow wave sleep) in adults with congenital central hypoventilation syndrome (CCHS), a rare genetic disease due to mutations in the PHOX2B gene. Fourteen patients aged 23 (19.0; 24.8) years old (median [1 rst -3rd quartiles]) with CCHS underwent a sleep interview and night-time attended polysomnography with their ventilatory support. Their sleep variables were compared to those collected in 15 healthy control subjects matched for age, sex and body mass index. The latency to N3 sleep was shorter in patients (26.3 min [24.0; 30.1]) than in controls (49.5 min [34.3; 66.9]; P = 0.005), and sleep onset latency tended to be shorter in patients (14.0 min [7.0; 20.5]) than in controls (33.0 min [18.0; 49.0]; P = 0.052). Total sleep time, sleep stage percentages, sleep fragmentation as well as respiratory and movement index were within normal ranges and not different between groups. Normal sleep in adult patients with CCHS and adequate ventilator support indicates that the PHOX2 gene mutations do not affect brain sleep networks. Consequently, any complaint of disrupted sleep should prompt clinicians to look for the usual causes of sleep disorders, primarily inadequate mechanical ventilation. Shorter N3 latency may indicate a higher need for slow wave sleep, to compensate for the abnormal respiratory-related cortical activity during awake quiet breathing observed in patients with CCH.
Bennett, D H; Fisk, W; Apte, M G; Wu, X; Trout, A; Faulkner, D; Sullivan, D
2012-08-01
This field study of 37 small and medium commercial buildings throughout California obtained information on ventilation rate, temperature, and heating, ventilating, and air-conditioning (HVAC) system characteristics. The study included seven retail establishments; five restaurants; eight offices; two each of gas stations, hair salons, healthcare facilities, grocery stores, dental offices, and fitness centers; and five other buildings. Fourteen (38%) of the buildings either could not or did not provide outdoor air through the HVAC system. The air exchange rate averaged 1.6 (s.d. = 1.7) exchanges per hour and was similar between buildings with and without outdoor air supplied through the HVAC system, indicating that some buildings have significant leakage or ventilation through open windows and doors. Not all buildings had sufficient air exchange to meet ASHRAE 62.1 Standards, including buildings used for fitness centers, hair salons, offices, and retail establishments. The majority of the time, buildings were within the ASHRAE temperature comfort range. Offices were frequently overcooled in the summer. All of the buildings had filters, but over half the buildings had a filter with a minimum efficiency reporting value rating of 4 or lower, which are not very effective for removing fine particles. Most U.S. commercial buildings (96%) are small- to medium-sized, using nearly 18% of the country's energy, and sheltering a large population daily. Little is known about the ventilation systems in these buildings. This study found a wide variety of ventilation conditions, with many buildings failing to meet relevant ventilation standards. Regulators may want to consider implementing more complete building inspections at commissioning and point of sale. © 2012 John Wiley & Sons A/S.
On the sound insulation of acoustic metasurface using a sub-structuring approach
NASA Astrophysics Data System (ADS)
Yu, Xiang; Lu, Zhenbo; Cheng, Li; Cui, Fangsen
2017-08-01
The feasibility of using an acoustic metasurface (AMS) with acoustic stop-band property to realize sound insulation with ventilation function is investigated. An efficient numerical approach is proposed to evaluate its sound insulation performance. The AMS is excited by a reverberant sound source and the standardized sound reduction index (SRI) is numerically investigated. To facilitate the modeling, the coupling between the AMS and the adjacent acoustic fields is formulated using a sub-structuring approach. A modal based formulation is applied to both the source and receiving room, enabling an efficient calculation in the frequency range from 125 Hz to 2000 Hz. The sound pressures and the velocities at the interface are matched by using a transfer function relation based on ;patches;. For illustration purposes, numerical examples are investigated using the proposed approach. The unit cell constituting the AMS is constructed in the shape of a thin acoustic chamber with tailored inner structures, whose stop-band property is numerically analyzed and experimentally demonstrated. The AMS is shown to provide effective sound insulation of over 30 dB in the stop-band frequencies from 600 to 1600 Hz. It is also shown that the proposed approach has the potential to be applied to a broad range of AMS studies and optimization problems.
Does thorax EIT image analysis depend on the image reconstruction method?
NASA Astrophysics Data System (ADS)
Zhao, Zhanqi; Frerichs, Inéz; Pulletz, Sven; Müller-Lisse, Ullrich; Möller, Knut
2013-04-01
Different methods were proposed to analyze the resulting images of electrical impedance tomography (EIT) measurements during ventilation. The aim of our study was to examine if the analysis methods based on back-projection deliver the same results when applied on images based on other reconstruction algorithms. Seven mechanically ventilated patients with ARDS were examined by EIT. The thorax contours were determined from the routine CT images. EIT raw data was reconstructed offline with (1) filtered back-projection with circular forward model (BPC); (2) GREIT reconstruction method with circular forward model (GREITC) and (3) GREIT with individual thorax geometry (GREITT). Three parameters were calculated on the resulting images: linearity, global ventilation distribution and regional ventilation distribution. The results of linearity test are 5.03±2.45, 4.66±2.25 and 5.32±2.30 for BPC, GREITC and GREITT, respectively (median ±interquartile range). The differences among the three methods are not significant (p = 0.93, Kruskal-Wallis test). The proportions of ventilation in the right lung are 0.58±0.17, 0.59±0.20 and 0.59±0.25 for BPC, GREITC and GREITT, respectively (p = 0.98). The differences of the GI index based on different reconstruction methods (0.53±0.16, 0.51±0.25 and 0.54±0.16 for BPC, GREITC and GREITT, respectively) are also not significant (p = 0.93). We conclude that the parameters developed for images generated with GREITT are comparable with filtered back-projection and GREITC.
Gadre, Shruti K.; Duggal, Abhijit; Mireles-Cabodevila, Eduardo; Krishnan, Sudhir; Wang, Xiao-Feng; Zell, Katrina; Guzman, Jorge
2018-01-01
Abstract There are limited data on the epidemiology of acute respiratory failure necessitating mechanical ventilation in patients with severe chronic obstructive pulmonary disease (COPD). The prognosis of acute respiratory failure requiring invasive mechanical ventilation is believed to be grim in this population. The purpose of this study was to illustrate the epidemiologic characteristics and outcomes of patients with underlying severe COPD requiring mechanical ventilation. A retrospective study of patients admitted to a quaternary referral medical intensive care unit (ICU) between January 2008 and December 2012 with a diagnosis of severe COPD and requiring invasive mechanical ventilation for acute respiratory failure. We evaluated 670 patients with an established diagnosis of severe COPD requiring mechanical ventilation for acute respiratory failure of whom 47% were male with a mean age of 63.7 ± 12.4 years and Acute physiology and chronic health evaluation (APACHE) III score of 76.3 ± 27.2. Only seventy-nine (12%) were admitted with a COPD exacerbation, 27(4%) had acute respiratory distress syndrome (ARDS), 78 (12%) had pneumonia, 78 (12%) had sepsis, and 312 (47%) had other causes of respiratory failure, including pulmonary embolism, pneumothorax, etc. Eighteen percent of the patients received a trial of noninvasive positive pressure ventilation. The median duration of mechanical ventilation was 3 days (interquartile range IQR 2–7); the median duration for ICU length of stay (LOS) was 5 (IQR 2–9) days and the median duration of hospital LOS was 12 (IQR 7–22) days. The overall ICU mortality was 25%. Patients with COPD exacerbation had a shorter median duration of mechanical ventilation (2 vs 4 days; P = .04), ICU (3 vs 5 days; P = .01), and hospital stay (10 vs 13 days; P = .01). The ICU mortality (9% vs 27%; P < .001), and the hospital mortality (17% vs 32%; P = .004) for mechanically ventilated patients with an acute exacerbation of severe COPD were lower than those with other etiologies of acute respiratory failure. A 1-unit increase in the APACHE III score was associated with a 1% decrease and having an active cancer was associated with a 45% decrease in ICU survival (P < .001). A discharge home at the time of index admission was associated an increased overall survival compared with any other discharge location (P < .001). We report good early outcomes, but significant long-term morbidity in patients with severe COPD requiring invasive mechanical ventilation for acute respiratory failure. A higher APACHE score and presence of active malignancy are associated with a decrease in ICU survival, whereas a discharge home is associated with an increase in the overall survival. PMID:29703009
Gadre, Shruti K; Duggal, Abhijit; Mireles-Cabodevila, Eduardo; Krishnan, Sudhir; Wang, Xiao-Feng; Zell, Katrina; Guzman, Jorge
2018-04-01
There are limited data on the epidemiology of acute respiratory failure necessitating mechanical ventilation in patients with severe chronic obstructive pulmonary disease (COPD). The prognosis of acute respiratory failure requiring invasive mechanical ventilation is believed to be grim in this population. The purpose of this study was to illustrate the epidemiologic characteristics and outcomes of patients with underlying severe COPD requiring mechanical ventilation.A retrospective study of patients admitted to a quaternary referral medical intensive care unit (ICU) between January 2008 and December 2012 with a diagnosis of severe COPD and requiring invasive mechanical ventilation for acute respiratory failure.We evaluated 670 patients with an established diagnosis of severe COPD requiring mechanical ventilation for acute respiratory failure of whom 47% were male with a mean age of 63.7 ± 12.4 years and Acute physiology and chronic health evaluation (APACHE) III score of 76.3 ± 27.2. Only seventy-nine (12%) were admitted with a COPD exacerbation, 27(4%) had acute respiratory distress syndrome (ARDS), 78 (12%) had pneumonia, 78 (12%) had sepsis, and 312 (47%) had other causes of respiratory failure, including pulmonary embolism, pneumothorax, etc. Eighteen percent of the patients received a trial of noninvasive positive pressure ventilation. The median duration of mechanical ventilation was 3 days (interquartile range IQR 2-7); the median duration for ICU length of stay (LOS) was 5 (IQR 2-9) days and the median duration of hospital LOS was 12 (IQR 7-22) days. The overall ICU mortality was 25%. Patients with COPD exacerbation had a shorter median duration of mechanical ventilation (2 vs 4 days; P = .04), ICU (3 vs 5 days; P = .01), and hospital stay (10 vs 13 days; P = .01). The ICU mortality (9% vs 27%; P < .001), and the hospital mortality (17% vs 32%; P = .004) for mechanically ventilated patients with an acute exacerbation of severe COPD were lower than those with other etiologies of acute respiratory failure. A 1-unit increase in the APACHE III score was associated with a 1% decrease and having an active cancer was associated with a 45% decrease in ICU survival (P < .001). A discharge home at the time of index admission was associated an increased overall survival compared with any other discharge location (P < .001).We report good early outcomes, but significant long-term morbidity in patients with severe COPD requiring invasive mechanical ventilation for acute respiratory failure. A higher APACHE score and presence of active malignancy are associated with a decrease in ICU survival, whereas a discharge home is associated with an increase in the overall survival.
Reduction of airborne radioactive dust by means of a charged water spray.
Bigu, J; Grenier, M G
1989-07-01
An electrostatic precipitator based on charged water spray technology has been used in an underground uranium mine to control long-lived radioactive dust and short-lived aerosol concentration in a mine gallery where dust from a rock breaking/ore transportation operation was discharged. Two main sampling stations were established: one upstream of the dust precipitator and one downstream. In addition, dust samplers were placed at different locations between the dust discharge and the end of the mine gallery. Long-lived radioactive dust was measured using cascade impactors and nylon cyclone dust samplers, and measurement of the radioactivity on the samples was carried out by conventional methods. Radon and thoron progeny were estimated using standard techniques. Experiments were conducted under a variety of airflow conditions. A maximum radioactive dust reduction of about 40% (approximately 20% caused by gravitational settling) at a ventilation rate of 0.61 m3/sec was obtained as a result of the combined action of water scrubbing and electrostatic precipitation by the charged water spray electrostatic precipitator. This represents the optimum efficiency attained within the range of ventilation rates investigated. The dust reduction efficiency of the charged water spray decreased with increasing ventilation rate, i.e., decreasing air residence time, and hence, reduced dust cloud/charged water droplets mixing time.
Turner, W A; Bearg, D W; Brennan, T
1995-01-01
This chapter begins with an overview of the history of ventilation guidelines, which has led to the guidelines that are in effect today. Of particular interest is the most recent return in the past 5 years to ventilation rates that more closely reflect a mean or average of the range of guidelines that have existed over the past century. OSHA's and the EPA's recognition of the need to operate ventilation systems in buildings in an accountable manner is also of note. Of even more interest is the resurgence of the concept of minimum mixing and once-through ventilation air that has been pursued in parts of Northern Europe for the past 10 years, and in a school that is being designed with this concept in New Hampshire. In addition, the design concept of equipping office buildings with low pressure drop high efficiency particle filtration to remove fine particles from all of the air that is supplied to the occupants is being used increasingly in the U.S. This chapter also presents an overview of the various types of ventilation systems found in homes and commercial office buildings and the common indoor air quality problems that may be associated with them. It also offers an overview of common HVAC evaluation techniques that can be used to determine if a ventilation system is performing in a manner that makes sense for the use of the space and the needs of the occupants. Are the occupants receiving a reasonable supply of outdoor air? Is the air that they receive of reasonable quality? Are obvious pollutants being exhausted? Ventilation systems have become extremely complex and more difficult to run and maintain over the past 40 years. This trend will continue to drive the need for professionally maintained HVAC equipment that is serviced and run by individuals who are accountable for the quality of the air that the system delivers.
Sharpe, Richard A; Thornton, Christopher R; Nikolaou, Vasilis; Osborne, Nicholas J
2015-06-01
Fuel poverty affects 2.4 million UK homes leading to poor hygrothermal conditions and risk of mould and house dust mite contaminations, which in turn increases risk of asthma exacerbation. For the first time we assess how fuel poverty, occupants' risk perception and use of mechanical ventilation mediate the risk of mould contamination in social housing. Postal questionnaires were sent to 3867 social housing properties to collect adult risk perception, and demographic and environmental information on occupants. Participant details were linked to data pertaining to the individual properties. Multiple logistic regression was used to calculate odds ratios and confidence intervals while allowing for clustering of individuals coming from the same housing estate. We used Structured Equation Modelling and Goodness of Fit analysis in mediation analyses to examine the role of fuel poverty, risk perception, use of ventilation and energy efficiency. Eighteen percent of our target social housing populations (671 households) were included into our study. High risk perception (score of 8-10) was associated with reduced risk of mould contamination in the bedrooms of children (OR 0.5 95% CI; 0.3-0.9) and adults (OR 0.4 95% CI; 0.3-0.7). High risk perception of living with inadequate heating and ventilation reduced the risk of mould contamination (OR 0.5 95% CI; 0.3-0.8 and OR 0.5 95% CI; 0.3-0.7, respectively). Participants living with inadequate heating and not heating due to the cost of fuel had an increased risk of mould contamination (OR 3.4 95% CI; 2.0-5.8 and OR 2.2 95% CI; 1.5-3.2, respectively). Increased risk perception and use of extractor fans did not mediate the association between fuel poverty behaviours and increased risk of mould contamination. Fuel poverty behaviours increased the risk of mould contamination, which corresponds with existing literature. For the first time we used mediation analysis to assess how this association maybe modified by occupant behaviours. Increased risk perception and use of extractor fans did not modify the association between fuel poverty and mould contamination. This suggests that fuel poor populations may not benefit from energy efficiency interventions due to ineffective heating and ventilation practices of those occupants residing participating households. Our findings may be modified by a complex interaction between occupant behaviours and the built environment. We found that participant age, occupancy, SES, pets, drying washing indoors, geographic location, architectural design/age of the property, levels of insulation and type of heating regulated risk of mould contamination. Fuel poverty behaviours affected around a third of participating households and represent a risk factor for increased exposures to damp and mouldy conditions, regardless of adult risk perception, heating and ventilation practices. This requires multidisciplinary approach to assess the complex interaction between occupant behaviours, risk perception, the built environment and the effective use of heating and ventilation practices. Our findings have implications for housing policies and future housing interventions. Effective communication strategies focusing on awareness and perception of risk may help address indoor air quality issues. This must be supported by improved household energy efficiency with the provision of more effective heating and ventilation strategies, specifically to help alleviate those suffering from fuel poverty. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisk, William J.; Destaillats, H.; Apte, M.G.
Heating, ventilating, and cooling classrooms in California consume substantial electrical energy. Indoor air quality (IAQ) in classrooms affects studenthealth and performance. In addition to airborne pollutants that are emitted directly by indoor sources and those generated outdoors, secondary pollutants can be formed indoors by chemical reaction of ozone with other chemicals and materials. Filters are used in nearly all classroom heating, ventilation and air?conditioning (HVAC) systems to maintain energy-efficient HVAC performance and improve indoor air quality; however, recent evidence indicates that ozone reactions with filters may, in fact, be a source of secondary pollutants. This project quantitatively evaluated ozone depositionmore » in HVAC filters and byproduct formation, and provided a preliminary assessment of the extent towhich filter systems are degrading indoor air quality. The preliminary information obtained will contribute to the design of subsequent research efforts and the identification of energy efficient solutions that improve indoor air quality in classrooms and the health and performance of students.« less
NASA Astrophysics Data System (ADS)
Chen, Liping; Guo, Yi; Peng, Xinsheng
2017-10-01
Particulate matter (PM2.5) pollution in air seriously affects public health. However, both bulk thickness and the accumulation of PM particles typically lead to a quick decline in the air permeability and large pressure drops of the conventional air clean membranes. In this work, we choose cellulose nanofibers (CNFs, a low cost, biodegradable and sustainable material) to form a hydrophobic and porous CNF thin layer on a stainless steel screen (300 mesh with pore size of 48 µm) through a simple filtration-assisted gelation process and subsequent polydimethylsiloxane modification. The prepared hydrophobic CNFs/stainless steel screen demonstrates highly efficient PM2.5 blocking based on size-sieving effect, fast air permeability and long-term durability under natural ventilation conditions in the relative humidity range from 45% to 93%. This technique holds great potential for indoor PM2.5 blocking under natural ventilation conditions.
A passive solar residence using native and recycled materials, Bee Cave, Texas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holder, L.M. III; King, L.H.
The Booth Residence at Bee Cave, Texas is a Passive Solar residence in a hot humid climate and a good example of both passive solar and renewable features. The design, operation, materials, and furnishings give the structure a regional and rustic character. Passive solar strategies employed include solar orientation, solar shading, natural ventilation, induced ventilation, night flushing, direct gain clearstory, high mass floors, daylighting, radiant barrier, and a double ventilated roof system. The project is in contrast to the existing compound which includes three identical buildings each rotated 120 degrees and intended to be energy efficient, but actual operation hasmore » pointed out some deficiencies in the design. Additional features include extensive use of natural, recycled, and materials reused from other buildings. The Boothe Residence is an example of building in harmony with the local climate, the use of locally available materials, craftsman, artists, manpower, and reuse of trim and furnishings.« less
Faustino, Eduardo Antonio
2007-06-01
In mechanical ventilation, invasive and noninvasive, the knowledge of respiratory mechanic physiology is indispensable to take decisions and into the efficient management of modern ventilators. Monitoring of pulmonary mechanic parameters is been recommended from all the review works and clinical research. The objective of this study was review concepts of pulmonary mechanic and the methods used to obtain measures in the bed side, preparing a rational sequence to obtain this data. It was obtained bibliographic review through data bank LILACS, MedLine and PubMed, from the last ten years. This review approaches parameters of resistance, pulmonary compliance and intrinsic PEEP as primordial into comprehension of acute respiratory failure and mechanic ventilatory support, mainly in acute respiratory distress syndrome (ARDS) and in chronic obstructive pulmonary disease (COPD). Monitoring pulmonary mechanics in patients under mechanical ventilation in intensive care units gives relevant informations and should be implemented in a rational and systematic way.
Performance and Life Tests of a Regenerative Blower for EVA Suit Ventilation
NASA Technical Reports Server (NTRS)
Izenson, Michael G.; Chen, Weibo; McCormick, John; Paul, Heather L.; Jennings, Mallory A.
2012-01-01
Ventilation fans for future space suits must meet demanding performance specifications, satisfy stringent safety requirements for operation in an oxygen atmosphere, and be able to increase output to operate in buddy mode. A regenerative blower is an attractive choice due to its ability to meet these requirements at low operating speed. This paper describes progress in the development and testing of a regenerative blower designed to meet requirements for ventilation subsystems in future space suits. The blower includes a custom-designed motor that has significantly improved its efficiency. We have measured the blower s head/flow performance and power consumption under conditions that simulate both the normal and buddy mode operating points. We have operated the blower for TBD hours and demonstrated safe operation in an oxygen test loop at prototypical pressures. We also demonstrated operation with simulated lunar dust.
Low-Flow Liquid Desiccant Air Conditioning: General Guidance and Site Considerations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kozubal, E.; Herrmann, L.; Deru, M.
2014-09-01
Dehumidification or latent cooling in buildings is an area of growing interest that has been identified as needing more research and improved technologies for higher performance. Heating, ventilating, and air-conditioning (HVAC) systems typically expend excessive energy by using overcool-and-reheat strategies to dehumidify buildings. These systems first overcool ventilation air to remove moisture and then reheat the air to meet comfort requirements. Another common strategy incorporates solid desiccant rotors that remove moisture from the air more efficiently; however, these systems increase fan energy consumption because of the high airside pressure drop of solid desiccant rotors and can add heat of absorptionmore » to the ventilation air. Alternatively, liquid desiccant air-conditioning (LDAC) technology provides an innovative dehumidification solution that: (1) eliminates the need for overcooling and reheating from traditional cooling systems; and (2) avoids the increased fan energy and air heating from solid desiccant rotor systems.« less
Performance and Life Tests of a Regenerative Blower for EVA Suit Ventilation
NASA Technical Reports Server (NTRS)
Izenson, Mike; Chen, Weibo; Paul, Heather L.; Jennings, Mallory A.
2011-01-01
Ventilation fans for future space suits must meet demanding performance specifications, satisfy stringent safety requirements for operation in an oxygen atmosphere, and be able to increase output to operate in buddy mode. A regenerative blower is an attractive choice due to its ability to meet these requirements at low operating speed. This paper describes progress in the development and testing of a regenerative blower designed to meet requirements for ventilation subsystems in a future space suit Portable Life Support Systems (PLSS). The blower assembly includes a custom-designed motor that has significantly improved in efficiency during this development effort. The blower was tested at both nominal and buddy mode operating points and head/flow performance and power consumption were measured. The blower was operated for over 1000 hours to demonstrate safe operation in an oxygen test loop at prototypical pressures. In addition, the blower demonstrated operation with the introduction of simulated lunar dust.
Annane, Djillali; Orlikowski, David; Chevret, Sylvie
2014-12-13
Chronic alveolar hypoventilation is a common complication of many neuromuscular and chest wall disorders. Long-term nocturnal mechanical ventilation is commonly used to treat it. This is a 2014 update of a review first published in 2000 and previously updated in 2007. To examine the effects on mortality of nocturnal mechanical ventilation in people with neuromuscular or chest wall disorders. Subsidiary endpoints were to examine the effects of respiratory assistance on improvement of chronic hypoventilation, sleep quality, hospital admissions and quality of life. We searched the Cochrane Neuromuscular Disease Group Specialized Register, CENTRAL, MEDLINE and EMBASE on 10 June 2014. We contacted authors of identified trials and other experts in the field. We searched for quasi-randomised or randomised controlled trials of participants of all ages with neuromuscular or chest wall disorder-related stable chronic hypoventilation of all degrees of severity, receiving any type and any mode of long-term nocturnal mechanical ventilation. The primary outcome measure was one-year mortality and secondary outcomes were unplanned hospital admission, short-term and long-term reversal of hypoventilation-related clinical symptoms and daytime hypercapnia, improvement of lung function and sleep breathing disorders. We used standard Cochrane methodology to select studies, extract data and assess the risk of bias in included studies. The 10 eligible trials included a total of 173 participants. Roughly half of the trials were at low risk of selection, attrition or reporting bias, and almost all were at high risk of performance and detection bias. Four trials reported mortality data in the long term. The pooled risk ratio (RR) of dying was 0.62 (95% confidence interval (CI) 0.42 to 0.91, P value = 0.01) in favour of nocturnal mechanical ventilation compared to spontaneous breathing. There was considerable and significant heterogeneity between the trials, possibly related to differences between the study populations. Information on unplanned hospitalisation was available from two studies. The corresponding pooled RR was 0.25 (95% CI 0.08 to 0.82, P value = 0.02) in favour of nocturnal mechanical ventilation. For most of the outcome measures there was no significant long-term difference between nocturnal mechanical ventilation and no ventilation. Most of the secondary outcomes were not assessed in the eligible trials. Three out of the 10 trials, accounting for 39 participants, two with a cross-over design and one with two parallel groups, compared volume- and pressure-cycled non-invasive mechanical ventilation in the short term. From the only trial (16 participants) on parallel groups, there was no difference in mortality (one death in each arm) between volume- and pressure-cycled mechanical ventilation. Data from the two cross-over trials suggested that compared with pressure-cycled ventilation, volume-cycled ventilation was associated with less sleep time spent with an arterial oxygen saturation below 90% (mean difference (MD) 6.83 minutes, 95% CI 4.68 to 8.98, P value = 0.00001) and a lower apnoea-hypopnoea (per sleep hour) index (MD -0.65, 95% CI -0.84 to -0.46, P value = 0.00001). We found no study that compared invasive and non-invasive mechanical ventilation or intermittent positive pressure versus negative pressure ventilation. Current evidence about the therapeutic benefit of mechanical ventilation is of very low quality, but is consistent, suggesting alleviation of the symptoms of chronic hypoventilation in the short term. In four small studies, survival was prolonged and unplanned hospitalisation was reduced, mainly in participants with motor neuron diseases. With the exception of motor neuron disease and Duchenne muscular dystrophy, for which the natural history supports the survival benefit of mechanical ventilation against no ventilation, further larger randomised trials should assess the long-term benefit of different types and modes of nocturnal mechanical ventilation on quality of life, morbidity and mortality, and its cost-benefit ratio in neuromuscular and chest wall diseases.
Chlif, Mehdi; Chaouachi, Anis; Ahmaidi, Said
2017-07-01
Obese patients show a decline in exercise capacity and diverse degrees of dyspnea in association with mechanical abnormalities, increased ventilatory requirements secondary to the increased metabolic load, and a greater work of breathing. Consequently, obese patients may be particularly predisposed to the development of respiratory muscle fatigue during exercise. The aim of this study was to assess inspiratory muscle performance during incremental exercise in 19 obese male subjects (body mass index 41 ± 6 kg/m 2 ) after aerobic exercise training using the noninvasive, inspiratory muscle tension-time index (T T0.1 ). Measurements performed included anthropometric parameters, lung function assessed by spirometry, rate of perceived breathlessness with the modified Borg dyspnea scale (0-10), breathing pattern, maximal exercise capacity, and inspiratory muscle performance with a breath-by-breath automated exercise metabolic system during an incremental exercise test. T T0.1 was calculated using the equation, T T0.1 = P 0.1 /P Imax × T I /T tot (where P 0.1 represents mouth occlusion pressure, P Imax is maximal inspiratory pressure, and T I /T tot is the duty cycle). At rest, there was no statistically significant difference for spirometric parameters and cardiorespiratory parameters between pre- and post-training. At maximal exercise, the minute ventilation, the rate of exchange ratio, the rate of perceived breathlessness, and the respiratory muscle performance parameters were not significantly different pre- and post-training; in contrast, tidal volume ( P = .037, effect size = 1.51), breathing frequency ( P = .049, effect size = 0.97), power output ( P = .048, effect size = 0.79), peak oxygen uptake ( P = .02, effect size = 0.92) were significantly higher after training. At comparable work load, training induces lower minute ventilation, mouth occlusion pressure, ratio of occlusion pressure to maximal inspiratory pressure, T T0.1 , and rate of perceived breathlessness. Aerobic exercise at ventilatory threshold can induce significant improvement in respiratory muscle strength, maximal exercise capacity, and inspiratory muscle performance and decreased dyspnea perception in obese subjects. Copyright © 2017 by Daedalus Enterprises.
Non stationary analysis of heart rate variability during the obstructive sleep apnea.
Méndez, M O; Bianchi, A M; Cerutti, S
2004-01-01
Characteristic fluctuations of the heart rate are found during obstructive sleep apnea (OSA), bradycardia in apneonic phase and tachycardia at the recovery of ventilation. In order to assess its autonomic response, in this study, the time-frequency distribution of Born-Jordan and evolutive Poincare plots are used. From Physionet was taken a database with records of ECG and respiratory signals. During the OSA all spectral indexes presented oscillations correspondent to the changes between brady and tachycardia of the RR intervals as well as greater values than during control epochs. Born-Jordan distribution and evolutive Poincare plots could help to characterize and develop an index for the evaluation of OSA. Very low frequency could also be a good index of OSA.
Itagaki, Taiga; Gubin, Tatyana A; Sayal, Puneet; Jiang, Yandong; Kacmarek, Robert M; Anderson, Thomas Anthony
2016-02-01
We hypothesized that anesthetized, apneic children could be ventilated equivalently or more efficiently by nasal mask ventilation (NMV) than face mask ventilation (FMV). The aim of this randomized controlled study was to test this hypothesis by comparing the expiratory tidal volume (Vte) between NMV and FMV. After the induction of anesthesia, 41 subjects, 3-17 years of age without anticipated difficult mask ventilation, were randomly assigned to receive either NMV or FMV with neck extension. Both groups were ventilated with pressure control ventilation (PCV) at 20 cmH2 O of peak inspiratory pressure (PIP) with positive end-expiratory pressure (PEEP) levels of 0, 5, and 10 cmH2 O. An additional mouth closing maneuver (MCM) was applied for the NMV group. The Vte was higher in the FMV group compared with the NMV group (median difference [95% CI]: 8.4 [5.5-11.6] ml·kg(-1) ; P < 0.001) when MCM was not applied. NMV achieved less PEEP than FMV (median difference [95% CI]: 5.0 [4.3-5.3] cmH2 O at 10 cmH2 O; P < 0.001) though both groups achieved the set PIP level. In the NMV group, MCM markedly increased Vte (median increase [95% CI]: 5.9 [2.5-9.0] ml·kg(-1) ; P < 0.005) and PEEP (median increase [95% CI]: 5.0 [0.6-8.6] cmH2 O at 10 cmH2 O; P < 0.005); however, PEEP was highly variable and lower than that of FMV (median difference [95% CI]: 2.5 [0.8-8.5] cmH2 O at 10 cmH2 O; P < 0.05). In anesthetized, apneic children greater than 2 years of age ventilated with an anesthesia ventilator and neck extension, FMV established a greater Vte than NMV regardless of mouth status. NMV could not maintain the set PEEP level due to an air leak from the mouth. The MCM increased the Vte and PEEP. © 2016 John Wiley & Sons Ltd.
Kim, MinJeong; Liu, Hongbin; Kim, Jeong Tai; Yoo, ChangKyoo
2014-08-15
Sensor faults in metro systems provide incorrect information to indoor air quality (IAQ) ventilation systems, resulting in the miss-operation of ventilation systems and adverse effects on passenger health. In this study, a new sensor validation method is proposed to (1) detect, identify and repair sensor faults and (2) evaluate the influence of sensor reliability on passenger health risk. To address the dynamic non-Gaussianity problem of IAQ data, dynamic independent component analysis (DICA) is used. To detect and identify sensor faults, the DICA-based squared prediction error and sensor validity index are used, respectively. To restore the faults to normal measurements, a DICA-based iterative reconstruction algorithm is proposed. The comprehensive indoor air-quality index (CIAI) that evaluates the influence of the current IAQ on passenger health is then compared using the faulty and reconstructed IAQ data sets. Experimental results from a metro station showed that the DICA-based method can produce an improved IAQ level in the metro station and reduce passenger health risk since it more accurately validates sensor faults than do conventional methods. Copyright © 2014 Elsevier B.V. All rights reserved.
Flexible HVAC System for Lab or Classroom.
ERIC Educational Resources Information Center
Friedan, Jonathan
2001-01-01
Discusses an effort to design a heating, ventilation, and air conditioning system flexible enough to accommodate an easy conversion of classrooms to laboratories and dry labs to wet labs. The design's energy efficiency and operations and maintenance are examined. (GR)
Effect of Ventilation Support on Oxidative Stress and Ischemia-Modified Albumin in Neonates.
Dursun, Arzu; Okumuş, Nurullah; Erol, Sara; Bayrak, Tülin; Zenciroğlu, Ayşegül
2016-01-01
Mechanical ventilation (MV) can induce oxidative stress, which plays a critical role in pulmonary injury in intubated neonates. Ischemia-modified albumin (IMA)-a variant of human serum albumin-is a novel biomarker of myocardial ischemia that occurs due to reactive oxygen species during ischemic insult. This study aimed to investigate IMA production due to oxidative stress induced during MV in neonates. This study included 17 neonates that were ventilated using synchronized intermittent mechanical ventilation (SIMV; SIMV group) and 20 neonates ventilated using continuous positive airway pressure (CPAP; CPAP group). Blood samples were collected from each neonate during ventilation support and following cessation of ventilation support. Total antioxidant capacity (TAC) and total oxidant status (TOS) were measured using the Erel method. IMA was measured via an enzyme-linked immunosorbent assay kit (Cusabio Biotech Co., Ltd., Wuhan, China). The oxidant stress index (OSI) was calculated as OSI = TOS/TAC. Statistical analysis was performed using SPSS v.18.0 (SPSS Inc., Chicago, IL) for Windows. Among the neonates included in the study, mean gestational age was 34.7 ± 3.8 weeks, mean birth weight was 2,553 ± 904 g, and 54% were premature. There were not any significant differences in mean gestational age or birth weight between the SIMV and CPAP groups. Among the neonates in both the groups, mean IMA, TOS, and OSI levels were significantly higher during ventilation support (102.2 ± 9.3 IU mL(-1), 15.5 ± 1.3 µmol H2O2 equivalent L(-1), and 0.85 ± 0.22 arbitrary units [ABU], respectively), as compared with following cessation of ventilation support (82.9 ± 11.9 IU mL(-1), 13.4 ± 1.3 µmol H2O2 equivalent L(-1), and 0.64 ± 0.14 ABU, respectively) (p = 0.001). Among all the neonates in the study, mean TAC was significantly lower during ventilation support than the postventilation support (1.82 ± 0.28 mmol 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid [Trolox] equivalent L(-1) vs. 2.16 ± 0.31 mmol Trolox equivalent L(-1)) (p = 0.001). There were no significant differences in mean TAC, OSI, or IMA levels between the SIMV and CPAP groups. The mean TOS level during ventilation support and the mean difference in TOS between during and postventilation support was significantly greater in the CPAP group than in the SIMV group. There were no significant relationships between the mean TOS, TAC, OSI, or IMA levels, and gestational age of the neonates. SIMV and CPAP activated the oxidative stress and increased the IMA level in neonates; therefore, measurement of IMA and oxidant markers may be useful in the follow-up of lung injury in neonates due to ventilation support. Additional prospective studies are needed to compare the effects of various ventilation methods on oxidative stress and the IMA level in neonates. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Hiltebrand, L B; Pestel, G; Hager, H; Ratnaraj, J; Sigurdsson, G H; Kurz, A
2007-11-01
Insufficient blood flow and oxygenation in the intestinal tract is associated with increased incidence of postoperative complications after bowel surgery. High fluid volume administration may prevent occult regional hypoperfusion and intestinal tissue hypoxia. We tested the hypothesis that high intraoperative fluid volume administration increases intestinal wall tissue oxygen pressure during laparotomy. In all, 27 pigs were anaesthetized, ventilated and randomly assigned to one of the three treatment groups (n = 9 in each) receiving low (3 mL kg-1 h-1), medium (7 mL kg-1 h-1) or high (20 mL kg-1 h-1) fluid volume treatment with lactated Ringer's solution. All animals received 30% and 100% inspired oxygen in random order. Cardiac index was measured with thermodilution and tissue oxygen pressure with a micro-oximetry system in the jejunum and colon wall and subcutaneous tissue. Groups receiving low and medium fluid volume treatment had similar systemic haemodynamics. The high fluid volume group had significantly higher mean arterial pressure, cardiac index and subcutaneous tissue oxygenation. Tissue oxygen pressures in the jejunum and colon were comparable in all three groups. The three different fluid volume regimens tested did not affect tissue oxygen pressure in the jejunum and colon, suggesting efficient autoregulation of intestinal blood flow in healthy subjects undergoing uncomplicated abdominal surgery.
[Sleep and respiratory disorders in myotonic dystrophy of Steinert].
López-Esteban, P; Peraita-Adrados, R
2000-03-01
It has been hypothesized that hypersomnia and sleep related respiratory impairment are both central in origin in myotonic dystrophy. To describe by means of video-polysomnographic recordings the central origin of the sleep respiratory disorders. We studied 11 patients, 6 men and 5 women (mean age 42.7 years) with myotonic dystrophy. A moderate to severe ventilatory impairment of a primarily restrictive type was seen in all patients, three of them after the first episode of respiratory insufficiency. The patients were evaluated in order to determine their body mass index and presence of sleep-related complaints. Video-polysomnographic recordings (EEG, EOG, EKG, submental and tibialis anterior EMGs, respiration and Sa02) and pulmonary function tests were performed in each patient. Identical recordings were repeated in six cases, which were to undergo non-invasive bi-level ventilation (BiPAP) in order to adjust the inspiratory and expiratory pressures and the machine mode. We found slight hypopnea and apnea, predominantly of a central type, in stage 1 and REM sleep and alveolar hypoventilation in all patients. Sleep was disrupted and the efficiency index was very low. In three patients HLA typing showed a positive DQ6 haplotype. Six patients were treated with n-BiPAP. Nasal-BIPAP should be considered as an alternative in ventilatory support during sleep in these patients and video-polysomnography as a valid method of evaluating the ideal time to start treatment.
Schiffmann, H; Singer, S; Singer, D; von Richthofen, E; Rathgeber, J; Züchner, K
1999-09-01
Thus far only few data are available on airway humidification during high-frequency oscillatory ventilation (HFOV). Therefore, we studied the performance and efficiency of a heated humidifier (HH) and a heat and moisture exchanger (HME) in HFOV using an artificial lung model. Experiments were performed with a pediatric high-frequency oscillatory ventilator. The artificial lung contained a sponge saturated with water to simulate evaporation and was placed in an incubator heated to 37 degrees C to prevent condensation. The airway humidity was measured using a capacitive humidity sensor. The water loss of the lung model was determined gravimetrically. The water loss of the lung model varied between 2.14 and 3.1 g/h during active humidification; it was 2.85 g/h with passive humidification and 7.56 g/h without humidification. The humidity at the tube connector varied between 34. 2 and 42.5 mg/l, depending on the temperature of the HH and the ventilator setting during active humidification, and between 37 and 39.9 mg/l with passive humidification. In general, HH and HME are suitable devices for airway humidification in HFOV. The performance of the ventilator was not significantly influenced by the mode of humidification. However, the adequacy of humidification and safety of the HME remains to be demonstrated in clinical practice.
WASTE HANDLING BUILDING VENTILATION SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
P.A. Kumar
2000-06-21
The Waste Handling Building Ventilation System provides heating, ventilation, and air conditioning (HVAC) for the contaminated, potentially contaminated, and uncontaminated areas of the Monitored Geologic Repository's (MGR) Waste Handling Building (WHB). In the uncontaminated areas, the non-confinement area ventilation system maintains the proper environmental conditions for equipment operation and personnel comfort. In the contaminated and potentially contaminated areas, in addition to maintaining the proper environmental conditions for equipment operation and personnel comfort, the contamination confinement area ventilation system directs potentially contaminated air away from personnel in the WHB and confines the contamination within high-efficiency particulate air (HEPA) filtration units. Themore » contamination confinement areas ventilation system creates airflow paths and pressure zones to minimize the potential for spreading contamination within the building. The contamination confinement ventilation system also protects the environment and the public by limiting airborne releases of radioactive or other hazardous contaminants from the WHB. The Waste Handling Building Ventilation System is designed to perform its safety functions under accident conditions and other Design Basis Events (DBEs) (such as earthquakes, tornadoes, fires, and loss of the primary electric power). Additional system design features (such as compartmentalization with independent subsystems) limit the potential for cross-contamination within the WHB. The system provides status of important system parameters and equipment operation, and provides audible and/or visual indication of off-normal conditions and equipment failures. The Waste Handling Building Ventilation System confines the radioactive and hazardous material within the building such that the release rates comply with regulatory limits. The system design, operations, and maintenance activities incorporate ALARA (as low as is reasonably achievable) principles to maintain personnel radiation doses to all occupational workers below regulatory limits and as low as is reasonably achievable. The Waste Handling Building Ventilation System interfaces with the Waste Handling Building System by being located within the WHB and by maintaining specific pressures, temperatures, and humidity within the building. The system also depends on the WHB for water supply. The system interfaces with the Site Radiological Monitoring System for continuous monitoring of the exhaust air; the Waste Handling Building Fire Protection System for detection of fire and smoke; the Waste Handling Building Electrical System for normal, emergency, and standby power; and the Monitored Geologic Repository Operations Monitoring and Control System for monitoring and control of the system.« less
Mathew, Lindsay; Wheatley, Andrew; Castillo, Richard; Castillo, Edward; Rodrigues, George; Guerrero, Thomas; Parraga, Grace
2012-12-01
Pulmonary functional imaging using four-dimensional x-ray computed tomographic (4DCT) imaging and hyperpolarized (3)He magnetic resonance imaging (MRI) provides regional lung function estimates in patients with lung cancer in whom pulmonary function measurements are typically dominated by tumor burden. The aim of this study was to evaluate the quantitative spatial relationship between 4DCT and hyperpolarized (3)He MRI ventilation maps. Eleven patients with lung cancer provided written informed consent to 4DCT imaging and MRI performed within 11 ± 14 days. Hyperpolarized (3)He MRI was acquired in breath-hold after inhalation from functional residual capacity of 1 L hyperpolarized (3)He, whereas 4DCT imaging was acquired over a single tidal breath of room air. For hyperpolarized (3)He MRI, the percentage ventilated volume was generated using semiautomated segmentation; for 4DCT imaging, pulmonary function maps were generated using the correspondence between identical tissue elements at inspiratory and expiratory phases to generate percentage ventilated volume. After accounting for differences in image acquisition lung volumes ((3)He MRI: 1.9 ± 0.5 L ipsilateral, 2.3 ± 0.7 L contralateral; 4DCT imaging: 1.2 ± 0.3 L ipsilateral, 1.3 ± 0.4 L contralateral), there was no significant difference in percentage ventilated volume between hyperpolarized (3)He MRI (72 ± 11% ipsilateral, 79 ± 12% contralateral) and 4DCT imaging (74 ± 3% ipsilateral, 75 ± 4% contralateral). Spatial correspondence between 4DCT and (3)He MRI ventilation was evaluated using the Dice similarity coefficient index (ipsilateral, 86 ± 12%; contralateral, 88 ± 12%). Despite rather large differences in image acquisition breathing maneuvers, good spatial and significant quantitative agreement was observed for ventilation maps on hyperpolarized (3)He MRI and 4DCT imaging, suggesting that pulmonary regions with good lung function are similar between modalities in this small group of patients with lung cancer. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
Li, Shengli; Wang, Xu; Li, Shoujun; Yan, Jun
2013-08-01
Acute respiratory distress syndrome (ARDS) in children after open heart surgery, although uncommon, can be a significant source of morbidity. Because high-frequency oscillatory ventilation (HFOV) had been used successfully with pediatric patients who had no congenital heart defects, this therapy was used in our unit. This report aims to describe a single-center experience with HFOV in the management of ARDS after open heart surgery with respect to mortality. This retrospective clinical study was conducted in a pediatric intensive care unit. From October 2008 to August 2012, 64 of 10,843 patients with refractory ARDS who underwent corrective surgery at our institution were ventilated with HFOV. Patients with significant uncorrected residual lesions were not included. No interventions were performed. The patients were followed up until hospital discharge. The main outcome measure was survival to hospital discharge. Severe ARDS was defined as acute-onset pulmonary failure with bilateral pulmonary infiltrates and an oxygenation index (OI) higher than 13 despite maximal ventilator settings. The indication for HFOV was acute severe ARDS unresponsive to optimal conventional treatment. The variables recorded and subjected to multivariate analysis were patient demographics, underlying disease, clinical data, and ventilator parameters and their association with hospital mortality. Nearly 10,843 patients underwent surgery during the study period, and the ARDS incidence rate was 0.76 % (83/10,843), with 64 patients (77 %, 64/83) receiving HFOV. No significant changes in systemic or central venous pressure were associated with initiation and maintenance of HFOV. The complications during HFOV included pneumothorax for 22 patients. The overall in-hospital mortality rate was 39 % (25/64). Multiple regression analyses indicated that pulmonary hypertension and recurrent respiratory tract infections (RRTIs) before surgery were independent predictors of in-hospital mortality. The findings show that HFOV is an effective and safe method for ventilating severe ARDS patients after corrective cardiac surgery. Pulmonary hypertension and RRTIs before surgery were risk factors for in-hospital mortality.
Oliveira-Costa, Clarice Daniele Alves de; Friedman, Gilberto; Vieira, Sílvia Regina Rios; Fialkow, Léa
2012-07-01
To determine the utility of pulse pressure variation (ΔRESP PP) in predicting fluid responsiveness in patients ventilated with low tidal volumes (V T) and to investigate whether a lower ΔRESP PP cut-off value should be used when patients are ventilated with low tidal volumes. This cross-sectional observational study included 37 critically ill patients with acute circulatory failure who required fluid challenge. The patients were sedated and mechanically ventilated with a V T of 6-7 ml/kg ideal body weight, which was monitored with a pulmonary artery catheter and an arterial line. The mechanical ventilation and hemodynamic parameters, including ΔRESP PP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase in the cardiac index of at least 15%. ClinicalTrial.gov: NCT01569308. A total of 17 patients were classified as responders. Analysis of the area under the ROC curve (AUC) showed that the optimal cut-off point for ΔRESP PP to predict fluid responsiveness was 10% (AUC = 0.74). Adjustment of the ΔRESP PP to account for driving pressure did not improve the accuracy (AUC = 0.76). A ΔRESP PP ≥ 10% was a better predictor of fluid responsiveness than central venous pressure (AUC = 0.57) or pulmonary wedge pressure (AUC = 051). Of the 37 patients, 25 were in septic shock. The AUC for ΔRESP PP ≥ 10% to predict responsiveness in patients with septic shock was 0.484 (sensitivity, 78%; specificity, 93%). The parameter D RESP PP has limited value in predicting fluid responsiveness in patients who are ventilated with low tidal volumes, but a ΔRESP PP>10% is a significant improvement over static parameters. A ΔRESP PP ≥ 10% may be particularly useful for identifying responders in patients with septic shock.
Methodological aspects of crossover and maximum fat-oxidation rate point determination.
Michallet, A-S; Tonini, J; Regnier, J; Guinot, M; Favre-Juvin, A; Bricout, V; Halimi, S; Wuyam, B; Flore, P
2008-11-01
Indirect calorimetry during exercise provides two metabolic indices of substrate oxidation balance: the crossover point (COP) and maximum fat oxidation rate (LIPOXmax). We aimed to study the effects of the analytical device, protocol type and ventilatory response on variability of these indices, and the relationship with lactate and ventilation thresholds. After maximum exercise testing, 14 relatively fit subjects (aged 32+/-10 years; nine men, five women) performed three submaximum graded tests: one was based on a theoretical maximum power (tMAP) reference; and two were based on the true maximum aerobic power (MAP). Gas exchange was measured concomitantly using a Douglas bag (D) and an ergospirometer (E). All metabolic indices were interpretable only when obtained by the D reference method and MAP protocol. Bland and Altman analysis showed overestimation of both indices with E versus D. Despite no mean differences between COP and LIPOXmax whether tMAP or MAP was used, the individual data clearly showed disagreement between the two protocols. Ventilation explained 10-16% of the metabolic index variations. COP was correlated with ventilation (r=0.96, P<0.01) and the rate of increase in blood lactate (r=0.79, P<0.01), and LIPOXmax correlated with the ventilation threshold (r=0.95, P<0.01). This study shows that, in fit healthy subjects, the analytical device, reference used to build the protocol and ventilation responses affect metabolic indices. In this population, and particularly to obtain interpretable metabolic indices, we recommend a protocol based on the true MAP or one adapted to include the transition from fat to carbohydrate. The correlation between metabolic indices and lactate/ventilation thresholds suggests that shorter, classical maximum progressive exercise testing may be an alternative means of estimating these indices in relatively fit subjects. However, this needs to be confirmed in patients who have metabolic defects.
Schwartz-Neiderman, Anat; Braun, Tali; Fallach, Noga; Schwartz, David; Carmeli, Yehuda; Schechner, Vered
2016-10-01
OBJECTIVE Carbapenemase-producing carbapenem-resistant Enterobacteriaceae (CP-CRE) are extremely drug-resistant pathogens. Screening of contacts of newly identified CP-CRE patients is an important step to limit further transmission. We aimed to determine the risk factors for CP-CRE acquisition among patients exposed to a CP-CRE index patient. METHODS A matched case-control study was performed in a tertiary care hospital in Israel. The study population was comprised of patients who underwent rectal screening for CP-CRE following close contact with a newly identified CP-CRE index patient. Cases were defined as positive tests for CP-CRE. For each case patient, 2 matched controls were randomly selected from the pool of contacts who tested negative for CP-CRE following exposure to the same index case. Bivariate and multivariate analyses were conducted using conditional logistic regression. RESULTS In total, 53 positive contacts were identified in 40 unique investigations (896 tests performed on 735 contacts) between October 6, 2008, and June 7, 2012. bla KPC was the only carbapenemase identified. In multivariate analysis, risk factors for CP-CRE acquisition among contacts were (1) contact with an index patient for ≥3 days (odds ratio [OR], 9.8; 95% confidence interval [CI], 2.0-48.9), (2) mechanical ventilation (OR, 4.1; 95% CI, 1.4-11.9), and (3) carriage or infection with another multidrug-resistant organism (MDRO; OR, 2.6; 95% CI, 1.0-7.1). Among patients who received antibiotics, cephalosporins were associated with a lower risk of acquisition. CONCLUSIONS Patient characteristics (ventilation and carriage of another MDRO) as well as duration of contact are risk factors for CP-CRE acquisition among contacts. The role of cephalosporins requires further study. Infect Control Hosp Epidemiol 2016;1-7.
Influence of etiology of heart failure on the obesity paradox.
Arena, Ross; Myers, Jonathan; Abella, Joshua; Pinkstaff, Sherry; Brubaker, Peter; Moore, Brian; Kitzman, Dalane; Peberdy, Mary Ann; Bensimhon, Daniel; Chase, Paul; Forman, Daniel; West, Erin; Guazzi, Marco
2009-10-15
Several investigations have demonstrated that higher body weight, as assessed by the body mass index, is associated with improved prognosis in patients with heart failure (HF). The purpose of the present investigation was to assess the influence of HF etiology on the prognostic ability of the body mass index in a cohort undergoing cardiopulmonary exercise testing. A total of 1,160 subjects were included in the analysis. All subjects underwent cardiopulmonary exercise testing, at which the minute ventilation/carbon dioxide production slope and peak oxygen consumption were determined. In the overall group, 193 cardiac deaths occurred during a mean follow-up of 30.7 +/- 25.6 months (annual event rate 6.0%). The subjects classified as obese consistently had improved survival compared to those classified as normal weight (overall survival rate 88.0% vs
Balzer, Felix; Menk, Mario; Ziegler, Jannis; Pille, Christian; Wernecke, Klaus-Dieter; Spies, Claudia; Schmidt, Maren; Weber-Carstens, Steffen; Deja, Maria
2016-11-08
Currently there is no ARDS definition or classification system that allows optimal prediction of mortality in ARDS patients. This study aimed to examine the predictive values of the AECC and Berlin definitions, as well as clinical and respiratory parameters obtained at onset of ARDS and in the course of the first seven consecutive days. The observational study was conducted at a 14-bed intensive care unit specialized on treatment of ARDS. Predictive validity of the AECC and Berlin definitions as well as P a O 2 /F i O 2 and F i O 2 /P a O 2 *P mean (oxygenation index) on mortality of ARDS patients was assessed and statistically compared. Four hundred forty two critically-ill patients admitted for ARDS were analysed. Multivariate Cox regression indicated that the oxygenation index was the most accurate parameter for mortality prediction. The third day after ARDS criteria were met at our hospital was found to represent the best compromise between earliness and accuracy of prognosis of mortality regarding the time of assessment. An oxygenation index of 15 or greater was associated with higher mortality, longer length of stay in ICU and hospital and longer duration of mechanical ventilation. In addition, non-survivors had a significantly longer length of stay and duration of mechanical ventilation in referring hospitals before admitted to the national reference centre than survivors. The oxygenation index is suggested to be the most suitable parameter to predict mortality in ARDS, preferably assessed on day 3 after admission to a specialized centre. Patients might benefit when transferred to specialized ICU centres as soon as possible for further treatment.
Lobeck, K M; Endres, M I; Shane, E M; Godden, S M; Fetrow, J
2011-11-01
The objective of this cohort study was to investigate animal welfare in 2 newer dairy housing options in the upper Midwest, cross-ventilated freestall barns (CV) and compost-bedded-pack barns (CB), compared with conventional, naturally ventilated freestall barns (NV). The study was conducted on 18 commercial dairy farms, 6 of each housing type, in Minnesota and eastern South Dakota. The primary breed in all farms was Holstein; 1 CV and 1 NV herd had approximately 30% Jersey-Holstein crossbreds. All freestall herds used sand for bedding. Farms were visited 4 times (once in each season) between January and November 2008, and approximately 93% of all animals in each pen were visually scored on each visit. Outcome-based measurements of welfare (locomotion, hock lesions, body condition score, hygiene, respiration rates, mortality, and mastitis prevalence) were collected on each farm. Lameness prevalence (proportion of cows with locomotion score ≥3 on a 1 to 5 scale, where 1=normal and 5=severely lame) in CB barns (4.4%) was lower than that in NV (15.9%) and CV (13.1%) barns. Lameness prevalence was similar between CV and NV barns. Hock lesion prevalence (proportion of cows with a lesion score ≥2 on a 1 to 3 scale, where 1=normal, 2=hair loss, and 3=swelling) was lower in CB barns (3.8%) than in CV (31.2%) and NV barns (23.9%). Hygiene scores (1 to 5 scale, where 1=clean and 5=very dirty) were higher for CB (3.18) than CV (2.83) and NV (2.77) barns, with no differences between CV and NV barns. Body condition scores, respiration rates, mastitis prevalence, culling, and mortality rates did not differ among housing systems. The CV and NV barns were evaluated using the cow comfort index (proportion of cows lying down in a stall divided by all animals touching a stall) and the stall usage index (proportion of cows lying divided by all animals in the pen not eating). The CV barns tended to have greater cow comfort index (85.9%) than the NV barns (81.4%) and had greater stall usage index (76.8% and 71.5%, respectively). Dairy cattle housed in CB barns had reduced lameness and hock lesions compared with those housed in freestall barns and had no adverse associations with body condition, respiration rates, mastitis prevalence, culling, or mortality. When comparing the 2 freestall housing options, CV barns had improved cow comfort indices compared with NV barns. Although cows in CB barns had better feet and leg health, as indicated by the reduced lameness and hock lesion prevalence, acquiring bedding and managing the bedded pack could limit their use. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Oral hygiene is an important factor for prevention of ventilator-associated pneumonia.
Par, Matej; Badovinac, Ana; Plancak, Darije
2014-03-01
Inadequate oral hygiene in intensive care units (ICUs) has been recognized as a critical issue, for it is an important risk factor for ventilator associated pneumonia (VAP). VAP is an aspiration pneumonia that occurs in mechanically ventilated patients, mostly caused by bacteria colonizing the oral cavity and dental plaque. It is the second most common nosocomial infection and the leading cause of complications and death in mechanically ventilated patients. It has been suggested that improvement of oral hygiene in ICU patients could lead to a reduced incidence of VAP. Although diverse oral care measures for ICU patients have been proposed in the literature, there is no evidence that could identify the most efficient ones. Although there are several evidence-based protocols, oral care measures are still performed inconsistently and differ greatly between individual ICUs. This paper lists the oral care measures most commonly performed in ICUs, indicating their advantages and disadvantages. Brushing with regular toothbrush and rinsing with chlorhexidine are considered optimal measures of oral hygiene in critically ill patients. To date, there is no definitive agreement about the most effective oral care protocol, but evidence demonstrates that consistent performance of oral care may lower the incidence of VAP in critically ill patients.
Air velocity distribution in a commercial broiler house
USDA-ARS?s Scientific Manuscript database
Increasing air velocity during tunnel ventilation in commercial broiler production facilities improves production efficiency, and many housing design specifications require a minimum air velocity. Air velocities are typically assessed with a hand-held velocity meter at random locations, rather than ...
Code of Federal Regulations, 2011 CFR
2011-01-01
... ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Provisions for Commercial Heating, Ventilating, Air-Conditioning and Water Heating Products § 431.172... conservation standard for that product. Basic model means, with respect to a commercial HVAC & WH product, all...
Colombo, Davide; Cammarota, Gianmaria; Bergamaschi, Valentina; De Lucia, Marta; Corte, Francesco Della; Navalesi, Paolo
2008-11-01
Neurally adjusted ventilatory assist (NAVA) is a new mode wherein the assistance is provided in proportion to diaphragm electrical activity (EAdi). We assessed the physiologic response to varying levels of NAVA and pressure support ventilation (PSV). ICU of a University Hospital. Fourteen intubated and mechanically ventilated patients. DESIGN AND PROTOCOL: Cross-over, prospective, randomized controlled trial. PSV was set to obtain a VT/kg of 6-8 ml/kg with an active inspiration. NAVA was matched with a dedicated software. The assistance was decreased and increased by 50% with both modes. The six assist levels were randomly applied. Arterial blood gases (ABGs), tidal volume (VT/kg), peak EAdi, airway pressure (Paw), neural and flow-based timing. Asynchrony was calculated using the asynchrony index (AI). There was no difference in ABGs regardless of mode and assist level. The differences in breathing pattern, ventilator assistance, and respiratory drive and timing between PSV and NAVA were overall small at the two lower assist levels. At the highest assist level, however, we found greater VT/kg (9.1 +/- 2.2 vs. 7.1 +/- 2 ml/kg, P < 0.001), and lower breathing frequency (12 +/- 6 vs. 18 +/- 8.2, P < 0.001) and peak EAdi (8.6 +/- 10.5 vs. 12.3 +/- 9.0, P < 0.002) in PSV than in NAVA; we found mismatch between neural and flow-based timing in PSV, but not in NAVA. AI exceeded 10% in five (36%) and no (0%) patients with PSV and NAVA, respectively (P < 0.05). Compared to PSV, NAVA averted the risk of over-assistance, avoided patient-ventilator asynchrony, and improved patient-ventilator interaction.
Karatas, Mevlut; Saylan, Sedat; Kostakoglu, Ugur; Yilmaz, Gurdal
2016-01-01
Objectives: Ventilator-associated pneumonia (VAP) is a significant cause of hospital-related infections, one that must be prevented due to its high morbidity and mortality. The purpose of this study was to evaluate the incidence and risk factors in patients developing VAP in our intensive care units (ICUs). Methods: This retrospective cohort study involved in mechanically ventilated patients hospitalized for more than 48 hours. VAP diagnosed patients were divided into two groups, those developing pneumonia (VAP(+)) and those not (VAP(-)).\\ Results: We researched 1560 patients in adult ICUs, 1152 (73.8%) of whom were mechanically ventilated. The MV use rate was 52%. VAP developed in 15.4% of patients. The VAP rate was calculated as 15.7/1000 ventilator days. Mean length of stay in the ICU for VAP(+) and VAP(-) patients were (26.7±16.3 and 18.1±12.7 days (p<0.001)) and mean length of MV use was (23.5±10.3 and 12.6±7.4 days (p<0.001)). High APACHE II and Charlson co-morbidity index scores, extended length of hospitalization and MV time, previous history of hospitalization and antibiotherapy, reintubation, enteral nutrition, chronic obstructive pulmonary disease, cerebrovascular disease, diabetes mellitus and organ failure were determined as significant risk factors for VAP. The mortality rate in the VAP(+) was 65.2%, with 23.6% being attributed to VAP. Conclusion: VAPs are prominent nosocomial infections that can cause considerable morbidity and mortality in ICUs. Patient care procedures for the early diagnosis of patients with a high risk of VAP and for the reduction of risk factors must be implemented by providing training concerning risk factors related to VAP for ICU personnel, and preventable risk factors must be reduced to a minimum. PMID:27648020
Bluth, T; Teichmann, R; Kiss, T; Bobek, I; Canet, J; Cinnella, G; De Baerdemaeker, L; Gregoretti, C; Hedenstierna, G; Hemmes, S N; Hiesmayr, M; Hollmann, M W; Jaber, S; Laffey, J G; Licker, M J; Markstaller, K; Matot, I; Müller, G; Mills, G H; Mulier, J P; Putensen, C; Rossaint, R; Schmitt, J; Senturk, M; Serpa Neto, A; Severgnini, P; Sprung, J; Vidal Melo, M F; Wrigge, H; Schultz, M J; Pelosi, P; Gama de Abreu, M
2017-04-28
Postoperative pulmonary complications (PPCs) increase the morbidity and mortality of surgery in obese patients. High levels of positive end-expiratory pressure (PEEP) with lung recruitment maneuvers may improve intraoperative respiratory function, but they can also compromise hemodynamics, and the effects on PPCs are uncertain. We hypothesized that intraoperative mechanical ventilation using high PEEP with periodic recruitment maneuvers, as compared with low PEEP without recruitment maneuvers, prevents PPCs in obese patients. The PRotective Ventilation with Higher versus Lower PEEP during General Anesthesia for Surgery in OBESE Patients (PROBESE) study is a multicenter, two-arm, international randomized controlled trial. In total, 2013 obese patients with body mass index ≥35 kg/m 2 scheduled for at least 2 h of surgery under general anesthesia and at intermediate to high risk for PPCs will be included. Patients are ventilated intraoperatively with a low tidal volume of 7 ml/kg (predicted body weight) and randomly assigned to PEEP of 12 cmH 2 O with lung recruitment maneuvers (high PEEP) or PEEP of 4 cmH 2 O without recruitment maneuvers (low PEEP). The occurrence of PPCs will be recorded as collapsed composite of single adverse pulmonary events and represents the primary endpoint. To our knowledge, the PROBESE trial is the first multicenter, international randomized controlled trial to compare the effects of two different levels of intraoperative PEEP during protective low tidal volume ventilation on PPCs in obese patients. The results of the PROBESE trial will support anesthesiologists in their decision to choose a certain PEEP level during general anesthesia for surgery in obese patients in an attempt to prevent PPCs. ClinicalTrials.gov identifier: NCT02148692. Registered on 23 May 2014; last updated 7 June 2016.
Increased risk of pneumonia among ventilated patients with traumatic brain injury: every day counts!
Hui, Xuan; Haider, Adil H; Hashmi, Zain G; Rushing, Amy P; Dhiman, Nitasha; Scott, Valerie K; Selvarajah, Shalini; Haut, Elliott R; Efron, David T; Schneider, Eric B
2013-09-01
Patients with traumatic brain injury (TBI) frequently require mechanical ventilation (MV). The objective of this study was to examine the association between time spent on MV and the development of pneumonia among patients with TBI. Patients older than 18 y with head abbreviated injury scale (AIS) scores coded 1-6 requiring MV in the National Trauma Data Bank 2007-2010 data set were included. The study was limited to hospitals reporting pneumonia cases. AIS scores were calculated using ICDMAP-90 software. Patients with injuries in any other region with AIS score >3, significant burns, or a hospital length of stay >30 d were excluded. A generalized linear model was used to determine the approximate relative risk of developing all-cause pneumonia (aspiration pneumonia, ventilator-associated pneumonia [VAP], and infectious pneumonia identified by the International Classification of Disease, Ninth Revision, diagnosis code) for each day of MV, controlling for age, gender, Glasgow coma scale motor score, comorbidity (Charlson comorbidity index) score, insurance status, and injury type and severity. Among the 24,525 patients with TBI who required MV included in this study, 1593 (6.5%) developed all-cause pneumonia. After controlling for demographic and injury factors, each additional day on the ventilator was associated with a 7% increase in the risk of pneumonia (risk ratio 1.07, 95% confidence interval 1.07-1.08). Patients who have sustained TBIs and require MV are at higher risk for VAP than individuals extubated earlier; therefore, shortening MV exposure will likely reduce the risk of VAP. As patients with TBI frequently require MV because of neurologic impairment, it is key to develop aggressive strategies to expedite ventilator independence. Copyright © 2013 Elsevier Inc. All rights reserved.
Wang, Juan; Zhuo, Chao-Nan; Zhang, Lei; Gong, Yu-Shun; Yin, Chang-Lin; Li, Yong-Qin
2015-01-01
The quality of chest compressions can be significantly improved after training of rescuers according to the latest national guidelines of China. However, rescuers may be unable to maintain adequate compression or ventilation throughout a response of average emergency medical services because of increased rescuer fatigue. In the present study, we evaluated the performance of cardiopulmonary resuscitation (CPR) in training of military medical university students during a prolonged basic life support (BLS). A 3-hour BLS training was given to 120 military medical university students. Six months after the training, 115 students performed single rescuer BLS on a manikin for 8 minutes. The qualities of chest compressions as well as ventilations were assessed. The average compression depth and rate were 53.7±5.3 mm and 135.1±15.7 compressions per minute respectively. The proportion of chest compressions with appropriate depth was 71.7%±28.4%. The average ventilation volume was 847.2±260.4 mL and the proportion of students with adequate ventilation was 63.5%. Compared with male students, significantly lower compression depth (46.7±4.8 vs. 54.6±4.8 mm, P<0.001) and adequate compression rate (35.5%±26.5% vs. 76.1%±25.1%, P<0.001) were observed in female students. CPR was found to be related to gender, body weight, and body mass index of students in this study. The quality of chest compressions was well maintained in male students during 8 minutes of conventional CPR but declined rapidly in female students after 2 minutes according to the latest national guidelines. Physical fitness and rescuer fatigue did not affect the quality of ventilation.
Wang, Juan; Zhuo, Chao-nan; Zhang, Lei; Gong, Yu-shun; Yin, Chang-lin; Li, Yong-qin
2015-01-01
BACKGROUND: The quality of chest compressions can be significantly improved after training of rescuers according to the latest national guidelines of China. However, rescuers may be unable to maintain adequate compression or ventilation throughout a response of average emergency medical services because of increased rescuer fatigue. In the present study, we evaluated the performance of cardiopulmonary resuscitation (CPR) in training of military medical university students during a prolonged basic life support (BLS). METHODS: A 3-hour BLS training was given to 120 military medical university students. Six months after the training, 115 students performed single rescuer BLS on a manikin for 8 minutes. The qualities of chest compressions as well as ventilations were assessed. RESULTS: The average compression depth and rate were 53.7±5.3 mm and 135.1±15.7 compressions per minute respectively. The proportion of chest compressions with appropriate depth was 71.7%±28.4%. The average ventilation volume was 847.2±260.4 mL and the proportion of students with adequate ventilation was 63.5%. Compared with male students, significantly lower compression depth (46.7±4.8 vs. 54.6±4.8 mm, P<0.001) and adequate compression rate (35.5%±26.5% vs. 76.1%±25.1%, P<0.001) were observed in female students. CONCLUSIONS: CPR was found to be related to gender, body weight, and body mass index of students in this study. The quality of chest compressions was well maintained in male students during 8 minutes of conventional CPR but declined rapidly in female students after 2 minutes according to the latest national guidelines. Physical fitness and rescuer fatigue did not affect the quality of ventilation. PMID:26401177
Nutritional status as a predictor of duration of mechanical ventilation in critically ill children.
Grippa, Rafaela B; Silva, Paola S; Barbosa, Eliana; Bresolin, Nilzete L; Mehta, Nilesh M; Moreno, Yara M F
2017-01-01
Critically ill children admitted to the pediatric intensive care unit (PICU) often are malnourished. The aim of this study was to determine the role of nutritional status on admission as a predictor of the duration of mechanical ventilation in critically ill children. This was a single-center, prospective cohort study, including consecutive children (ages 1 mo to 15 y) admitted to a PICU. Demographic characteristics, clinical characteristics, and nutritional status were recorded and patients were followed up until hospital discharge. Nutritional status was evaluated by anthropometric parameters and malnutrition was considered if the Z-scores for the parameters were ≤-2. Adjusted Cox's regression analysis was used to determine the association between nutritional status and duration of mechanical ventilation. In all, 72 patients were included. The prevalence of malnutrition was 41.2%, according to height-for-age Z-score, 18.6% according to weight-for-height Z-score, and 22.1% according body mass index-for-age Z-score. Anthropometrical parameters that predicted the duration of mechanical ventilation were weight-for-age (hazard ratio [HR], 2.73; 95% confidence interval [CI], 1.44-5.18); height-for-age (HR, 2.49; 95% CI, 1.44-4.28); and upper arm muscle area-for-age (HR, 5.22; 95% CI, 1.19-22.76). Malnutrition, based on a variety of anthropometric variables, was associated with the duration of mechanical ventilation in this cohort of critically ill children. Assessment of nutritional status by anthropometry should be performed on admission to the PICU to allow targeted nutritional rehabilitation for the subset of children with existing malnutrition. Copyright © 2016 Elsevier Inc. All rights reserved.
A ventilation strategy during general anaesthesia to reduce postoperative atelectasis.
Edmark, Lennart; Auner, Udo; Hallén, Jan; Lassinantti-Olowsson, Lena; Hedenstierna, Göran; Enlund, Mats
2014-08-01
Atelectasis is common during and after general anaesthesia. We hypothesized that a ventilation strategy, without recruitment manoeuvres, using a combination of continuous positive airway pressure (CPAP) or positive end-expiratory pressure (PEEP) and a reduced end-expiratory oxygen fraction (FETO2) before ending mask ventilation with CPAP after extubation would reduce the area of postoperative atelectasis. Thirty patients were randomized into three groups. During induction and emergence, inspiratory oxygen fractions (FIO2) were 1.0 in the control group and 1.0 or 0.8 in the intervention groups. No CPAP/PEEP was used in the control group, whereas CPAP/PEEP of 6 cmH2O was used in the intervention groups. After extubation, FIO2 was set to 0.30 in the intervention groups and CPAP was applied, aiming at FETO2 < 0.30. Atelectasis was studied by computed tomography 25 min postoperatively. The median area of atelectasis was 5.2 cm(2) (range 1.6-12.2 cm(2)) and 8.5 cm(2) (3-23.1 cm(2)) in the groups given FIO2 1.0 with or without CPAP/PEEP, respectively. After correction for body mass index the difference between medians (2.9 cm(2)) was statistically significant (confidence interval 0.2-7.6 cm(2), p = 0.04). In the group given FIO2 0.8, in which seven patients were ex- or current smokers, the median area of atelectasis was 8.2 cm(2) (1.8-14.7 cm(2)). Compared with conventional ventilation, after correction for obesity, this ventilation strategy reduced the area of postoperative atelectasis in one of the intervention groups but not in the other group, which included a higher proportion of smokers.
A ventilation strategy during general anaesthesia to reduce postoperative atelectasis
Auner, Udo; Hallén, Jan; Lassinantti-Olowsson, Lena; Hedenstierna, Göran; Enlund, Mats
2014-01-01
Background Atelectasis is common during and after general anaesthesia. We hypothesized that a ventilation strategy, without recruitment manoeuvres, using a combination of continuous positive airway pressure (CPAP) or positive end-expiratory pressure (PEEP) and a reduced end-expiratory oxygen fraction (FETO2) before ending mask ventilation with CPAP after extubation would reduce the area of postoperative atelectasis. Methods Thirty patients were randomized into three groups. During induction and emergence, inspiratory oxygen fractions (FIO2) were 1.0 in the control group and 1.0 or 0.8 in the intervention groups. No CPAP/PEEP was used in the control group, whereas CPAP/PEEP of 6 cmH2O was used in the intervention groups. After extubation, FIO2 was set to 0.30 in the intervention groups and CPAP was applied, aiming at FETO2 < 0.30. Atelectasis was studied by computed tomography 25 min postoperatively. Results The median area of atelectasis was 5.2 cm2 (range 1.6–12.2 cm2) and 8.5 cm2 (3–23.1 cm2) in the groups given FIO2 1.0 with or without CPAP/PEEP, respectively. After correction for body mass index the difference between medians (2.9 cm2) was statistically significant (confidence interval 0.2–7.6 cm2, p = 0.04). In the group given FIO2 0.8, in which seven patients were ex- or current smokers, the median area of atelectasis was 8.2 cm2 (1.8–14.7 cm2). Conclusion Compared with conventional ventilation, after correction for obesity, this ventilation strategy reduced the area of postoperative atelectasis in one of the intervention groups but not in the other group, which included a higher proportion of smokers. PMID:24758245
Mechanisms of breathing instability in patients with obstructive sleep apnea.
Younes, Magdy; Ostrowski, Michele; Atkar, Raj; Laprairie, John; Siemens, Andrea; Hanly, Patrick
2007-12-01
The response to chemical stimuli (chemical responsiveness) and the increases in respiratory drive required for arousal (arousal threshold) and for opening the airway without arousal (effective recruitment threshold) are important determinants of ventilatory instability and, hence, severity of obstructive apnea. We measured these variables in 21 obstructive apnea patients (apnea-hypopnea index 91 +/- 24 h(-1)) while on continuous-positive-airway pressure. During sleep, pressure was intermittently reduced (dial down) to induce severe hypopneas. Dial downs were done on room air and following approximately 30 s of breathing hypercapneic and/or hypoxic mixtures, which induced a range of ventilatory stimulation before dial down. Ventilation just before dial down and flow during dial down were measured. Chemical responsiveness, estimated as the percent increase in ventilation during the 5(th) breath following administration of 6% CO(2) combined with approximately 4% desaturation, was large (187 +/- 117%). Arousal threshold, estimated as the percent increase in ventilation associated with a 50% probability of arousal, ranged from 40% to >268% and was <120% in 12/21 patients, indicating that in many patients arousal occurs with modest changes in chemical drive. Effective recruitment threshold, estimated as percent increase in pre-dial-down ventilation associated with a significant increase in dial-down flow, ranged from zero to >174% and was <110% in 12/21 patients, indicating that in many patients reflex dilatation occurs with modest increases in drive. The two thresholds were not correlated. In most OSA patients, airway patency may be maintained with only modest increases in chemical drive, but instability results because of a low arousal threshold and a brisk increase in drive following brief reduction in alveolar ventilation.
Ultrafine particle removal by residential heating, ventilating, and air-conditioning filters.
Stephens, B; Siegel, J A
2013-12-01
This work uses an in situ filter test method to measure the size-resolved removal efficiency of indoor-generated ultrafine particles (approximately 7-100 nm) for six new commercially available filters installed in a recirculating heating, ventilating, and air-conditioning (HVAC) system in an unoccupied test house. The fibrous HVAC filters were previously rated by the manufacturers according to ASHRAE Standard 52.2 and ranged from shallow (2.5 cm) fiberglass panel filters (MERV 4) to deep-bed (12.7 cm) electrostatically charged synthetic media filters (MERV 16). Measured removal efficiency ranged from 0 to 10% for most ultrafine particles (UFP) sizes with the lowest rated filters (MERV 4 and 6) to 60-80% for most UFP sizes with the highest rated filter (MERV 16). The deeper bed filters generally achieved higher removal efficiencies than the panel filters, while maintaining a low pressure drop and higher airflow rate in the operating HVAC system. Assuming constant efficiency, a modeling effort using these measured values for new filters and other inputs from real buildings shows that MERV 13-16 filters could reduce the indoor proportion of outdoor UFPs (in the absence of indoor sources) by as much as a factor of 2-3 in a typical single-family residence relative to the lowest efficiency filters, depending in part on particle size. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Berndtson, Allison E; Sen, Soman; Greenhalgh, David G; Palmieri, Tina L
2013-09-01
The purpose of our study is to validate the Pediatric Risk of Mortality (PRISM) score and compare the accuracy of PRISM predicted outcomes to the Abbreviated Burn Severity Index (ABSI). We hypothesized that the PRISM score is more accurate in predicting mortality and hospital length of stay than the ABSI in children with severe burns. All children <18 years of age admitted to a regional pediatric burn center between January 1, 2008 and July 1, 2010 were reviewed. Those with a Total Body Surface Area (TBSA) burn ≥20% who were admitted within 7 days of injury were selected for our study. Measured parameters included: demographics, burn characteristics, PRISM and ABSI scores at admission, and outcomes (mortality, hospital length of stay (LOS), ventilator days and cause of death). A total of 83 patients met criteria and had complete data sets. The mean age (±SEM) was 8.0±0.6 years, mean % TBSA burn 49.9±2.1%, 62.7% were male, and 45.8% had inhalation injury. Hospital LOS was 74.4±7.9 days, with 31.5±4.9 ventilator days. Mean PRISM score ranged from 14.2 to 16.0, with ABSI scores 7.9 to 8.5. Actual overall mortality was 18.1% compared to a PRISM predicted mortality of 19.8±2.5% (p<0.001, r=0.570). ABSI predicted mortality varied from 10 to 20% for a score of 7.9 to 30-50% for a score of 8.5. Logistic regression showed that both PRISM (p<0.001) and ABSI (p<0.001) mortality predictions accurately estimated actual mortality, which remained true in a combined model. ABSI was predictive of hospital LOS (p<0.001) and ventilator days (p<0.001) while PRISM was not (p=0.326 and p=0.863). Both PRISM and ABSI scores are predictive of mortality in severely burned children. Only ABSI correlates with hospital length of stay and ventilator days, and thus may also be more useful in predicting ICU resource utilization. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Liu, L; Liu, D Z; Wang, Q P; Zhu, Z L; Li, H M; Lu, X Y
2017-01-01
This paper aimed to analyze the effects of respiratory training on pulmonary function during the rehabilitation period for acute organic fluorine-poisoned patients treated by non-invasive positive pressure ventilation (NIPPV). Sixty-two acute organic fluorine-poisoned patients admitted to the Xinxiang Central Hospital, Xinxiang City, China, from May 2012 to March 2016 were selected and randomly divided into an observation group and a control group, with 31 cases in each. Both groups received NIPPV. The patients in the control group exercised daily, while the patients in the observation group received contracting lips-abdominal breathing training. The therapeutic effects, pulmonary ventilation function, serum levels of α-antitrypsin1 (α-AT1), surfactant protein D (SP-D), neutrophil elastase (NE), transforming growth factor beta 1 (TGF-β1), and quality of life were analyzed and compared between the two groups both before and after the administration of treatment. The total effective rate of the observation group was 93.55%, which was significantly higher when compared with the control group (74.19%) (P less than 0.05). The levels of forced expiratory volume in one second (FEV1), FEV1/FVC ratio, vital capacity (VC), carbon monoxide diffusion capacity (DLco), and maximal voluntary ventilation (MVV) of the observation group were better when compared with the control group and had statistical significance (P less than 0.05). Before treatment, the serum levels of α-AT1, SP-D, NE, and TGF-β1, and quality of life had no statistical significance in either group (P>0.05); after treatment, these indexes and the quality of life for the observation group were significantly higher when compared with the control group, with statistical significance (P less than 0.05). The respiratory training in acute organic fluorine-poisoned patients treated by NIPPV can improve the serum indexes, dilute toxicity, and recover pulmonary function, which play key roles in improving the therapeutic effects and quality of life of patients, and is worthy of clinical promotion.
2012-01-01
Introduction Capillary leak in critically ill patients leads to interstitial edema. Fluid overload is independently associated with poor prognosis. Bedside measurement of intra-abdominal pressure (IAP), extravascular lung water index (EVLWI), fluid balance, and capillary leak index (CLI) may provide a valuable prognostic tool in mechanically ventilated patients. Methods We performed an observational study of 123 mechanically ventilated patients with extended hemodynamic monitoring, analyzing process-of-care variables for the first week of ICU admission. The primary outcome parameter was 28-day mortality. ΔmaxEVLWI indicated the maximum difference between EVLWI measurements during ICU stay. Patients with a ΔmaxEVLWI <−2 mL/kg were called 'responders'. CLI was defined as C-reactive protein (milligrams per deciliter) over albumin (grams per liter) ratio and conservative late fluid management (CLFM) as even-to-negative fluid balance on at least two consecutive days. Results CLI had a biphasic course. ΔmaxEVLWI was lower if CLFM was achieved and in survivors (−2.4 ± 4.8 vs 1.0 ± 5.5 mL/kg, p = 0.001; −3.3 ± 3.8 vs 2.5 ± 5.3 mL/kg, p = 0.001, respectively). No CLFM achievement was associated with increased CLI and IAPmean on day 3 and higher risk to be nonresponder (odds ratio (OR) 2.76, p = 0.046; OR 1.28, p = 0.011; OR 5.52, p = 0.001, respectively). Responders had more ventilator-free days during the first week (2.5 ± 2.3 vs 1.5 ± 2.3, p = 0.023). Not achieving CLFM and being nonresponder were strong independent predictors of mortality (OR 9.34, p = 0.001 and OR 7.14, p = 0.001, respectively). Conclusion There seems to be an important correlation between CLI, EVLWI kinetics, IAP, and fluid balance in mechanically ventilated patients, associated with organ dysfunction and poor prognosis. In this context, we introduce the global increased permeability syndrome. PMID:22873410
Hanvoravongchai, Piya; Chavez, Irwin; Rudge, James W; Touch, Sok; Putthasri, Weerasak; Chau, Pham Ngoc; Phommasack, Bounlay; Singhasivanon, Pratap; Coker, Richard
2012-12-14
There is increasing perception that countries cannot work in isolation to militate against the threat of pandemic influenza. In the Greater Mekong Subregion (GMS) of Asia, high socio-economic diversity and fertile conditions for the emergence and spread of infectious diseases underscore the importance of transnational cooperation. Investigation of healthcare resource distribution and inequalities can help determine the need for, and inform decisions regarding, resource sharing and mobilisation. We collected data on healthcare resources deemed important for responding to pandemic influenza through surveys of hospitals and district health offices across four countries of the GMS (Cambodia, Lao PDR, Thailand, Vietnam). Focusing on four key resource types (oseltamivir, hospital beds, ventilators, and health workers), we mapped and analysed resource distributions at province level to identify relative shortages, mismatches, and clustering of resources. We analysed inequalities in resource distribution using the Gini coefficient and Theil index. Three quarters of the Cambodian population and two thirds of the Laotian population live in relatively underserved provinces (those with resource densities in the lowest quintile across the region) in relation to health workers, ventilators, and hospital beds. More than a quarter of the Thai population is relatively underserved for health workers and oseltamivir. Approximately one fifth of the Vietnamese population is underserved for beds and ventilators. All Cambodian provinces are underserved for at least one resource. In Lao PDR, 11 percent of the population is underserved by all four resource items. Of the four resources, ventilators and oseltamivir were most unequally distributed. Cambodia generally showed higher levels of inequalities in resource distribution compared to other countries. Decomposition of the Theil index suggests that inequalities result principally from differences within, rather than between, countries. There is considerable heterogeneity in healthcare resource distribution within and across countries of the GMS. Most inequalities result from within countries. Given the inequalities, mismatches, and clustering of resources observed here, resource sharing and mobilization in a pandemic scenario could be crucial for more effective and equitable use of the resources that are available in the GMS.
2007-12-01
Ventilation, and Air Conditioning IED Improvised Explosive Device IG DoD Inspector General, Department of Defense IGA Investment Grade Audit JLTV...that certain energy efficient improvements will be achieved (Hansen, 2003). Investment Grade Audit (IGA). Based on the premise that energy...low- grade propane; and a modified diesel engine that can burn gas, ethanol, and diesel fuel in variable proportions (Hamilton, 2007). The TGER
Sustainability Actions in Higher Education
DOE Office of Scientific and Technical Information (OSTI.GOV)
This brochure details common sustainability actions taken by universities to reduce their energy consumption. Some of the most common actions include energy efficiency (existing building commissioning; lighting; heating, ventilation, and air conditioning upgrades; plug loads) and renewable energy (RE) (on-site or off-site solar deployment, RE procurement). We focus on the costs and benefits of energy efficiency measures and RE through the brochure while highlighting resources where readers can find more information.
Influence of ventilation and filtration on indoor particle concentrations in urban office buildings
NASA Astrophysics Data System (ADS)
Quang, Tran Ngoc; He, Congrong; Morawska, Lidia; Knibbs, Luke D.
2013-11-01
This study aimed to quantify the efficiency of deep bag and electrostatic filters, and assess the influence of ventilation systems using these filters on indoor fine (<2.5 μm) and ultrafine particle concentrations in commercial office buildings. Measurements and modelling were conducted for different indoor and outdoor particle source scenarios at three office buildings in Brisbane, Australia. Overall, the in-situ efficiency, measured for particles in size ranges 6-3000 nm, of the deep bag filters ranged from 26.3 to 46.9% for the three buildings, while the in-situ efficiency of the electrostatic filter in one building was 60.2%. The highest PN and PM2.5 concentrations in one of the office buildings (up to 131% and 31% higher than the other two buildings, respectively) were due to the proximity of the building's HVAC air intakes to a nearby bus-only roadway, as well as its higher outdoor ventilation rate. The lowest PN and PM2.5 concentrations (up to 57% and 24% lower than the other two buildings, respectively) were measured in a building that utilised both outdoor and mixing air filters in its HVAC system. Indoor PN concentrations were strongly influenced by outdoor levels and were significantly higher during rush-hours (up to 41%) and nucleation events (up to 57%), compared to working-hours, for all three buildings. This is the first time that the influence of new particle formation on indoor particle concentrations has been identified and quantified. A dynamic model for indoor PN concentration, which performed adequately in this study also revealed that using mixing/outdoor air filters can significantly reduce indoor particle concentration in buildings where indoor air was strongly influenced by outdoor particle levels. This work provides a scientific basis for the selection and location of appropriate filters and outdoor air intakes, during the design of new, or upgrade of existing, building HVAC systems. The results also serve to provide a better understanding of indoor particle dynamics and behaviours under different ventilation and particle source scenarios, and highlight effective methods to reduce exposure to particles in commercial office buildings.
Prisk, G Kim
2005-09-01
The lung is exquisitely sensitive to gravity, which induces gradients in ventilation, blood flow, and gas exchange. Studies of lungs in microgravity provide a means of elucidating the effects of gravity. They suggest a mechanism by which gravity serves to match ventilation to perfusion, making for a more efficient lung than anticipated. Despite predictions, lungs do not become edematous, and there is no disruption to, gas exchange in microgravity. Sleep disturbances in microgravity are not a result of respiratory-related events; obstructive sleep apnea is caused principally by the gravitational effects on the upper airways. In microgravity, lungs may be at greater risk to the effects of inhaled aerosols.
Measure Guideline: Guide to Attic Air Sealing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lstiburek, Joseph
2014-09-01
The purpose of this measure guideline is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guide is to save energy, health, safety, and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to themore » work that needs to be done.« less
NASA Technical Reports Server (NTRS)
Prisk, G. Kim
2005-01-01
The lung is exquisitely sensitive to gravity, which induces gradients in ventilation, blood flow, and gas exchange. Studies of lungs in microgravity provide a means of elucidating the effects of gravity. They suggest a mechanism by which gravity serves to match ventilation to perfusion, making for a more efficient lung than anticipated. Despite predictions, lungs do not become edematous, and there is no disruption to, gas exchange in microgravity. Sleep disturbances in microgravity are not a result of respiratory-related events; obstructive sleep apnea is caused principally by the gravitational effects on the upper airways. In microgravity, lungs may be at greater risk to the effects of inhaled aerosols.
Nonuniformity of diffusing capacity from small alveolar gas samples is increased in smokers.
Cotton, D J; Mink, J T; Graham, B L
1998-01-01
Although centrilobular emphysema, and small airway, interstitial and alveoli inflammation can be detected pathologically in the lungs of smokers with relatively well preserved lung function, these changes are difficult to assess using available physiological tests. Because submaximal single breath washout (SBWSM) manoeuvres improve the detection of abnormalities in ventilation inhomogeneity in the lung periphery in smokers compared with traditional vital capacity manoeuvres, SBWSM manoeuvres were used in this study to measure temporal differences in diffusing capacity using a rapid response carbon monoxide analyzer. To determine whether abnormalities in the lung periphery can be detected in smokers with normal forced expired volumes in 1 s using the three-equation diffusing capacity (DLcoSB-3EQ) among small alveolar gas samples and whether the abnormalities correlate with increases in peripheral ventilation inhomogeneity. Cross-sectional study in 21 smokers and 21 nonsmokers all with normal forced exhaled flow rates. Both smokers and nonsmokers performed SBWSM manoeuvres consisting of slow inhalation of test gas from functional residual capacity to one-half inspiratory capacity with either 0 or 10 s of breath holding and slow exhalation to residual volume (RV). They also performed conventional vital capacity single breath (SBWVC) manoeuvres consisting of slow inhalation of test gas from RV to total lung capacity and, without breath holding, slow exhalation to RV. DLcoSB-3EQ was calculated from the total alveolar gas sample. DLcoSB-3EQ was also calculated from four equal sequential, simulated aliquots of the total alveolar gas sample. DLcoSB-3EQ values from the four alveolar samples were normalized by expressing each as a percentge of DLcoSB-3EQ from the entire alveolar gas sample. An index of variation (DI) among the small-sample DLcoSB-3EQ values was correlated with the normalized phase III helium slope (Sn) and the mixing efficiency (Emix). For SBWSM, DI was increased in smokers at 0 s of breath holding compared with nonsmokers, and correlated with age, smoking pack-years and Sn. The decrease in DI with breath holding was greater in smokers and correlated with the change in Sn with breath holding. For SBWVC manoeuvres, there were no differences due to smoking in Sn or Emix, but DI was increased in smokers and correlated with age and smoking pack-years, but not with Sn. For SBWSM manoeuvres the increase in DI in smokers correlated with breath hold time-dependent increases in Sn, suggesting that the changes in DI reflected the same structural alterations that caused increases in peripheral ventilation inhomogeneity. For SBWVC manoeuvres, the increase in DI in smokers was not associated with changes in ventilation inhomogeneity, suggesting that the effect of smoking on DI during this manoeuvre was due to smoke-related changes in alveolar capillary diffusion, rather than due solely to alterations in the distribution of ventilation.
Qi, Chaolong; Stanley, Nick; Pui, David Y H; Kuehn, Thomas H
2008-06-01
An automotive cabin air filter's effectiveness for removing airborne particles was determined both in a laboratory wind tunnel and in vehicle on-road tests. The most penetrating particle size for the test filter was approximately 350 nm, where the filtration efficiency was 22.9 and 17.4% at medium and high fan speeds, respectively. The filtration efficiency increased for smaller particles and was 43.9% for 100 nm and 72.0% for 20 nm particles at a medium fan speed. We determined the reduction in passenger exposure to particles while driving in freeway traffic caused by a vehicle ventilation system with a cabin air filter installed. Both particle number and surface area concentration measurements were made inside the cabin and in the surrounding air. At medium fan speed, the number and surface area concentration-based exposure reductions were 65.6 +/- 6.0% and 60.6 +/- 9.4%, respectively. To distinguish the exposure reduction contribution from the filter alone and the remainder of the ventilation system, we also performed tests with and without the filter in place using the surface area monitors. The ventilation system operating in the recirculation mode with the cabin air filter installed provided the maximum protection, reducing the cabin particle concentration exponentially over time and usually taking only 3 min to reach 10 microm2/cm3 (a typical office air condition) under medium fan speed.
Healthy Efficient New Gas Homes (HENGH) Pilot Test Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chan, Wanyu R.; Maddalena, Randy L; Stratton, Chris
The Healthy Efficient New Gas Homes (HENGH) is a field study that will collect data on ventilation systems and indoor air quality (IAQ) in new California homes that were built to 2008 Title 24 standards. A pilot test was performed to help inform the most time and cost effective approaches to measuring IAQ in the 100 test homes that will be recruited for this study. Two occupied, single-family detached homes built to 2008 Title 24 participated in the pilot test. One of the test homes uses exhaust-only ventilation provided by a continuous exhaust fan in the laundry room. The othermore » home uses supply air for ventilation. Measurements of IAQ were collected for two weeks. Time-resolved concentrations of particulate matter (PM), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde were measured. Measurements of IAQ also included time-integrated concentrations of volatile organic compounds (VOCs), volatile aldehydes, and NO2. Three perfluorocarbon tracers (PFTs) were used to estimate the dilution rate of an indoor emitted air contaminant in the two pilot test homes. Diagnostic tests were performed to measure envelope air leakage, duct leakage, and airflow of range hood, exhaust fans, and clothes dryer vent when accessible. Occupant activities, such as cooking, use of range hood and exhaust fans, were monitored using various data loggers. This document describes results of the pilot test.« less
USDA-ARS?s Scientific Manuscript database
Particulate matter emitted from tunnel-ventilated animal feeding operations (AFOs) is known to transport malodorous compounds. As a mitigation strategy, vegetative environmental buffers (VEBs) are often installed surrounding AFOs to capture particulates and induce lofting and dispersion. Currently, ...
ERIC Educational Resources Information Center
Randall, Kathleen
1993-01-01
Describes how renovation can transform a school to a state-of-the-art facility without having to work from the ground up. Examined are the planning and design phases, the outer structure upgrading, the installation of more efficient heating, ventilation, and air conditioning systems, and renovation costs. (GR)
Ferrando, Carlos; Suarez-Sipmann, Fernando; Tusman, Gerardo; León, Irene; Romero, Esther; Gracia, Estefania; Mugarra, Ana; Arocas, Blanca; Pozo, Natividad; Soro, Marina; Belda, Francisco J
2017-01-01
Low tidal volume (VT) during anesthesia minimizes lung injury but may be associated to a decrease in functional lung volume impairing lung mechanics and efficiency. Lung recruitment (RM) can restore lung volume but this may critically depend on the post-RM selected PEEP. This study was a randomized, two parallel arm, open study whose primary outcome was to compare the effects on driving pressure of adding a RM to low-VT ventilation, with or without an individualized post-RM PEEP in patients without known previous lung disease during anesthesia. Consecutive patients scheduled for major abdominal surgery were submitted to low-VT ventilation (6 ml·kg-1) and standard PEEP of 5 cmH2O (pre-RM, n = 36). After 30 min estabilization all patients received a RM and were randomly allocated to either continue with the same PEEP (RM-5 group, n = 18) or to an individualized open-lung PEEP (OL-PEEP) (Open Lung Approach, OLA group, n = 18) defined as the level resulting in maximal Cdyn during a decremental PEEP trial. We compared the effects on driving pressure and lung efficiency measured by volumetric capnography. OL-PEEP was found at 8±2 cmH2O. 36 patients were included in the final analysis. When compared with pre-RM, OLA resulted in a 22% increase in compliance and a 28% decrease in driving pressure when compared to pre-RM. These parameters did not improve in the RM-5. The trend of the DP was significantly different between the OLA and RM-5 groups (p = 0.002). VDalv/VTalv was significantly lower in the OLA group after the RM (p = 0.035). Lung recruitment applied during low-VT ventilation improves driving pressure and lung efficiency only when applied as an open-lung strategy with an individualized PEEP in patients without lung diseases undergoing major abdominal surgery. ClinicalTrials.gov NCT02798133.
Lam, K S; Chan, F S; Fung, W Y; Lui, B S S; Lau, L W L
2006-04-01
A study was carried out to investigate the feasibility of achieving ultra low respirable suspended particulates (RSP) in commercial offices without major modification of existing ventilation systems by enhancing the particulates removal efficiency of existing central ventilation systems. Four types of filters which include pre-filters, cartridge filters, bag filters and high efficiency particulates air (HEPA) filters were tested in a commercial building in Causeway Bay. The results show that an RSP objective of <20 microg/m3 could be met by removing RSP from both the return air and outdoor air supply simultaneously. This level of performance is classed as 'excellent' by the Hong Kong Government, Environmental Protection Department. Filters with efficiency that exceed 80% placed both in the return air and outdoor air were sufficient to meet the objective. It is not necessary to install HEPA filters to achieve the 'excellent' class. The outdoor air filter has great influence on the steady state indoor RSP concentration while the effective cleaning rate is governed by the return air filter. Higher efficiency filters increased the static drop but the volume flow of the air fan was not affected significantly. The additional cost incurred was <5% of the existing operation cost. This paper reports a field study of RSP control for an indoor office environment. The results are directly applicable to building service engineering in the design of ventilation systems using air-handling units. Field observations indicated that indoor RSP in an office environment could be suppressed below 20 microg/m3 within 1 h by the simultaneous filtration of outdoor air and return air. Outdoor air filtration has a great influence on the steady state indoor concentration and return air filtration governs the cleaning rate. It is believed that the results of this study could be extended to the cleaning of other indoor pollutants such as volatile organic compounds.
Aghaie, Bahman; Rejeh, Nahid; Heravi-Karimooi, Majideh; Ebadi, Abbas; Moradian, Seyed Tayeb; Vaismoradi, Mojtaba; Jasper, Melanie
2014-04-01
Weaning from mechanical ventilation is a frequent nursing activity in critical care. Nature-based sound as a non-pharmacological and nursing intervention effective in other contexts may be an efficient approach to alleviating anxiety, agitation and adverse effects of sedative medication in patients undergoing weaning from mechanical ventilation. This study identified the effect of nature-based sound therapy on agitation and anxiety on coronary artery bypass graft patients during weaning from mechanical ventilation. A randomised clinical trial design was used. 120 coronary artery bypass graft patients aged 45-65 years undergoing weaning from mechanical ventilation were randomly assigned to intervention and control groups. Patients in the intervention group listened to nature-based sounds through headphones; the control group had headphones with no sound. Haemodynamic variables, anxiety levels and agitation were assessed using the Faces Anxiety Scale and Richmond Agitation Sedation Scale, respectively. Patients in both groups had vital signs recorded after the first trigger, at 20 min intervals throughout the procedure, immediately after the procedure, 20 min after extubation, and 30 min after extubation. Data were collected over 5 months from December 2012 to April 2013. The intervention group had significantly lower anxiety and agitation levels than the control group. Regarding haemodynamic variables, a significant time trend and interaction was reported between time and group (p<0.001). A significant difference was also found between the anxiety (p<0.002) and agitation (p<0.001) scores in two groups. Nature-based sound can provide an effective method of decreasing potential adverse haemodynamic responses arising from anxiety and agitation in weaning from mechanical ventilation in coronary artery bypass graft patients. Nurses can incorporate this intervention as a non-pharmacological intervention into the daily care of patients undergoing weaning from mechanical ventilation in order to reduce their anxiety and agitation. Copyright © 2013 Elsevier Ltd. All rights reserved.
Lazure, L P
2000-09-01
Fiber-reinforced plastics are used to manufacture a large variety of products, particularly for the transportation sector. Hand lay-up molding and projection molding are the main methods of manufacture. The users of these processes are exposed to appreciable emissions of styrene; in Quebec, more than 3000 workers work in this industry. A statistical analysis of styrene concentrations measured over a five-year period by the Institut de recherche en santé et en sécurité du travail (IRSST, Occupational Health and Safety Research Institute) reveals that for all of the main manufacturing sectors involved, between 40 percent and 78 percent of the results exceed the exposure standard of 50 ppm. This study evaluated the effectiveness of a ventilated table in controlling worker exposure to styrene and acetone in a shop that manufactures fiber-reinforced plastics parts. The evaluated local extraction system consists of a ventilated table with a surface area of 1.2 m x 1.2 m. During molding, the styrene emissions are exhausted through the ventilated table as well as through the slots in a lateral hood. Replacement air, introduced vertically through a supply air shower located above the worker, limits the diffusion of contaminants toward the worker's breathing zone. The reduction in worker exposure to styrene and acetone during hand lay-up molding was measured in the breathing zone for two sizes of molds. The results show that exhaust ventilation reduced the styrene concentrations by 91 percent and that the introduction of replacement air increased the efficiency of the ventilated table to 96 percent. The evaluation performed indicates that the ventilated table adequately controls worker exposure to styrene and acetone during the molding of small components.
Thiéry, Guillaume; Boyer, Alexandre; Pigné, Etienne; Salah, Amar; De Lassence, Arnaud; Dreyfuss, Didier; Ricard, Jean-Damien
2003-03-01
To determine whether use of a hygroscopic and hydrophobic heat and moisture exchanger (HME) for 7 days without change affects its efficiency in long-term, mechanically ventilated, chronic obstructive pulmonary disease (COPD) patients. Prospective, randomized, controlled clinical study comparing two combined HMEs. Medical intensive care unit at a university teaching hospital. Long-term, mechanically ventilated, COPD patients compared with non-COPD patients. In the first part of the study, COPD patients were studied with the Hygroster HME changed once a week. For the second part, the Hygroster was assessed in non-COPD patients and compared with the Hygrobac HME used in COPD and non-COPD patients for 1 wk without change. Devices could be changed if hygrometric measurements indicated insufficient humidity delivery. Daily measurements were recorded for inspired gas temperature and relative and absolute humidity. Ventilatory variables, clinical indicators of efficient humidification, were also recorded. No tracheal tube occlusion occurred. However, contrary to the manufacturer advertisement, the Hygroster experienced surprisingly low values for absolute humidity in both COPD and non-COPD patients. Such events did not occur with the Hygrobac. Absolute humidity with the Hygroster was constantly and significantly lower during the 7-day study period than with the Hygrobac. Absolute humidity measured in COPD patients was identical to that measured in the rest of the study population with both HMEs. Manufacturer specifications and bedside measurements of absolute humidity differed considerably for the Hygroster, which in certain instances did not achieve efficient humidification in both COPD and non-COPD patients. This did not occur with the Hygrobac, which performed well throughout the 7-day period in both COPD and non-COPD patients. Our results speak for independent and evaluation of HMEs.
Minegishi, Taeko; Allen, Joseph G.; McCarthy, John F.; Spengler, John D.; MacIntosh, David L.
2014-01-01
Objective Many interventions to reduce allergen levels in the home are recommended to asthma and allergy patients. One that is readily available and can be highly effective is the use of high performing filters in forced air ventilation systems. Methods We conducted a modeling analysis of the effectiveness of filter-based interventions in the home to reduce airborne asthma and allergy triggers. This work used “each pass removal efficiency” applied to health-relevant size fractions of particles to assess filter performance. We assessed effectiveness for key allergy and asthma triggers based on applicable particle sizes for cat allergen, indoor and outdoor sources of particles <2.5 µm in diameter (PM2.5), and airborne influenza and rhinovirus. Results Our analysis finds that higher performing filters can have significant impacts on indoor particle pollutant levels. Filters with removal efficiencies of >70% for cat dander particles, fine particulate matter (PM2.5) and respiratory virus can lower concentrations of those asthma triggers and allergens in indoor air of the home by >50%. Very high removal efficiency filters, such as those rated a 16 on the nationally recognized Minimum Efficiency Removal Value (MERV) rating system, tend to be only marginally more effective than MERV12 or 13 rated filters. Conclusions The results of this analysis indicate that use of a MERV12 or higher performing air filter in home ventilation systems can effectively reduce indoor levels of these common asthma and allergy triggers. These reductions in airborne allergens in turn may help reduce allergy and asthma symptoms, especially if employed in conjunction with other environmental management measures recommended for allergy and asthma patients. PMID:24555523
Nonalcoholic steatohepatitis in bariatric patients with a diagnosis of obstructive sleep apnea.
Weingarten, Toby N; Mantilla, Carlos B; Swain, James M; Kendrick, Michael L; Oberhansley, Jeff M; Burcham, Robert J; Ribeiro, Tarsila C R; Watt, Kymberly D; Schroeder, Darrell R; Narr, Bradly J; Sprung, Juraj
2012-01-01
To study a possible association between obstructive sleep apnea (OSA) severity, managed with noninvasive ventilation, and nonalcoholic steatohepatitis (NASH) in bariatric surgical patients. Medical records of 218 bariatric surgical patients who underwent liver biopsy were reviewed. OSA severity was determined from preoperative polysomnography (apnea-hypopnea index (AHI) ≤ 15 no/mild OSA vs. AHI ≥ 16 moderate/severe OSA). Patients diagnosed with OSA were prescribed noninvasive ventilation. Patients were categorized according to liver histopathology into 3 groups: (i) no liver disease or simple steatosis, (ii) mild NASH (steatosis with necroinflammation and mild fibrosis (stage 0-1)), and iii) advanced NASH (steatosis with necroinflammation and more advanced fibrosis (stage ≥ 2)). 125 patients (57%) had no/mild OSA, and 93 (43%) had moderate/severe OSA. There was no difference in serum aminotransferases between patients by OSA severity classification. There was a high prevalence of hepatic histopathological abnormalities: 84% patients had steatosis, 57% had necroinflammation, 34% had fibrotic changes, and 14% had advanced NASH. There was no association between severity of NASH and severity of OSA. There is no association between stage of steatohepatitis and OSA severity among morbidly obese patients managed with noninvasive ventilation.
NASA Technical Reports Server (NTRS)
Agui, Juan H.; Vijayakumar, R.; Perry, Jay L.; Frederick, Kenneth R.; Mccormick, Robert M.
2017-01-01
Human deep space exploration missions will require advances in long-life, low maintenance airborne particulate matter filtration technology. As one of the National Aeronautics and Space Administrations (NASA) developments in this area, a prototype of a new regenerable, multi-stage particulate matter filtration technology was tested in an International Space Station (ISS) module simulation facility. As previously reported, the key features of the filter system include inertial and media filtration with regeneration and in-place media replacement techniques. The testing facility can simulate aspects of the cabin environment aboard the ISS and contains flight-like cabin ventilation system components. The filtration technology test article was installed at the inlet of the central ventilation system duct and instrumented to provide performance data under nominal flow conditions. In-place regeneration operations were also evaluated. The real-time data included pressure drop across the filter stages, process air flow rate, ambient pressure, humidity and temperature. In addition, two video cameras positioned at the filtration technology test articles inlet and outlet were used to capture the mechanical performance of the filter media indexing operation under varying air flow rates. Recent test results are presented and future design recommendations are discussed.
Patient-ventilator asynchrony, leaks and sleep in patients with amyotrophic lateral sclerosis.
Vrijsen, Bart; Testelmans, Dries; Belge, Catharina; Vanpee, Goele; Van Damme, Philip; Buyse, Bertien
2016-01-01
Sleeping with non-invasive ventilation (NIV) in amyotrophic lateral sclerosis appears to be accompanied by a high patient-ventilator asynchrony (PVA) index. This prospective observational cohort study quantifies PVA and leaks, and searches for effects of these events on sleep after polysomnographic NIV titration. Full-video polysomnography, with incorporation of transcutaneous carbon dioxide and ventilator software, was used to analyse sleep epoch-by-epoch and respiratory events and PVA breath-by-breath in 35 patients (17 non-bulbar). After diagnostic polysomnography, NIV was titrated during three consecutive nights. Sleep, PVA and leaks were evaluated at discharge and after one month. Results showed that non-bulbar patients improved in sleep architecture and oxygen and carbon dioxide levels while bulbar patients only improved oxygen saturation. PVA remained present at discharge (non-bulbar 54 (21-101) and bulbar 31 (9-39)/h sleep) and one month (non-bulbar 31 (9-39) and bulbar 32 (17-55)/h sleep), with ineffective effort as most prominent asynchrony. Leaks also persisted after titration (non-bulbar 16.6 (3.1-44.6) and bulbar 5.1 (0.0-19.5)% of total sleep time (TST)) and one month (non-bulbar 7.7 (1.4-29.3) and bulbar 12.7 (0.0-35.2)% TST). PVA and leaks have none to minor effect on sleep architecture. In conclusion, although PVA and leaks remain present after meticulous NIV titration, these events seem not to interfere with sleep.
Testing of mechanical ventilators and infant incubators in healthcare institutions.
Badnjevic, Almir; Gurbeta, Lejla; Jimenez, Elvira Ruiz; Iadanza, Ernesto
2017-01-01
The medical device industry has grown rapidly and incessantly over the past century. The sophistication and complexity of the designed instrumentation is nowadays rising and, with it, has also increased the need to develop some better, more effective and efficient maintenance processes, as part of the safety and performance requirements. This paper presents the results of performance tests conducted on 50 mechanical ventilators and 50 infant incubators used in various public healthcare institutions. Testing was conducted in accordance to safety and performance requirements stated in relevant international standards, directives and legal metrology policies. Testing of output parameters for mechanical ventilators was performed in 4 measuring points while testing of output parameters for infant incubators was performed in 7 measuring points for each infant incubator. As performance criteria, relative error of output parameters for mechanical ventilators and absolute error of output parameters for infant incubators was calculated. The ranges of permissible error, for both groups of devices, are regulated by the Rules on Metrological and Technical Requirements published in the Official Gazette of Bosnia and Herzegovina No. 75/14, which are defined based on international recommendations, standards and guidelines. All ventilators and incubators were tested by etalons calibrated in an ISO 17025 accredited laboratory, which provides compliance to international standards for all measured parameters.The results show that 30% of the tested medical devices are not operating properly and should be serviced, recalibrated and/or removed from daily application.
Komasawa, Nobuyasu; Ueki, Ryusuke; Iwasaki, Yohei; Tatara, Tsuneo; Tashiro, Chikara; Kaminoh, Yoshiroh
2012-10-01
A 79-year-old man was diagnosed with maxillary cancer and underwent total maxillectomy under general anesthesia. The oropharyngeal airway was needed for efficient mask ventilation during anesthesia induction. The maxilla was totally resected and reconstructed with skin from a femoral flap. Tracheal extubation was considered to be difficult given that mask ventilation was contraindicated due to reconstruction of the maxilla. After inserting a tube exchanger (TE) into the trachea, the tracheal tube was exchanged with an air-Q laryngeal airway through the TE. After confirming effective ventilation with the air-Q mask, the patient was awakened from anesthesia. We confirmed sufficient spontaneous breathing and no active bleeding in the pharynx. After re-inserting the TE thorough air-Q, the air-Q was removed, followed by removal of the TE. These findings suggest that the air-Q and TE were effective in a case of difficult extubation after maxillectomy.
Chemical Emissions of Residential Materials and Products: Review of Available Information
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willem, Henry; Singer, Brett
2010-09-15
This report is prepared in the context of a larger program whose mission is to advance understanding of ventilation and indoor air quality in U.S. homes. A specific objective of this program is to develop the scientific basis ? through controlled experiments, monitoring and analysis ? for health risk-based ventilation standards. Appropriate and adequate ventilation is a basic element of a healthy home. Ventilation provides outdoor air and in the process removes indoor odors and contaminants including potentially unhealthful chemicals emitted by indoor materials, products and activities. Ventilation traditionally was assured to occur via infiltration of outdoor air through cracksmore » and other leakage pathways in the residential building envelope. As building air tightness is improved for energy efficiency, infiltration can be reduced to inadequate levels. This has lead to the development of standards requiring mechanical ventilation. Though nominally intended to ensure acceptable indoor air quality, the standards are not explicitly tied to health risk or pollutant exposure targets. LBNL is currently designing analyses to assess the impact of varying ventilation standards on pollutant concentrations, health risks and energy use. These analyses require information on sources of chemical pollutant emissions, ideally including emission rates and the impact of ventilation on emissions. Some information can be obtained from recent studies that report measurements of various air contaminants and their concentrations in U.S. residences. Another way to obtain this information is the bottom-up approach of collecting and evaluating emissions data from construction and interior materials and common household products. This review contributes to the latter approach by summarizing available information on chemical emissions from new residential products and materials. We review information from the scientific literature and public sources to identify and discuss the databases that provide information on new or low-emission materials and products. The review focuses on the primary chemical or volatile organic compound (VOC) emissions from interior surface materials, furnishings, and some regularly used household products; all of these emissions are amenable to ventilation. Though it is an important and related topic, this review does not consider secondary pollutants that result from reactions of ozone and unsaturated organics bound to or emitted from material surfaces. Semi-volatile organic compounds (SVOCs) have been largely excluded from this review because ventilation generally is not an effective way to control SVOC exposures. Nevertheless, health concerns about exposures to SVOCs emitted from selected materials warrant some discussion.« less
Frade-Mera, M J; Regueiro-Díaz, N; Díaz-Castellano, L; Torres-Valverde, L; Alonso-Pérez, L; Landívar-Redondo, M M; Muñoz-Pasín, R; Terceros-Almanza, L J; Temprano-Vázquez, S; Sánchez-Izquierdo-Riera, J Á
Safe analgesia and sedation strategies are necessary in order to avoid under or over sedation, as well as improving the comfort and safety of critical care patients. To compare and contrast a multidisciplinary protocol of systematic evaluation and management of analgesia and sedation in a group of critical care patients on mechanical ventilation with the usual procedures. A cohort study with contemporary series was conducted in a tertiary care medical-surgical ICU February to November during 2013 and 2014. The inclusion criteria were mechanical ventilation ≥ 24h and use of sedation by continuous infusion. Sedation was monitored using the Richmond agitation-sedation scale or bispectral index, and analgesia were measured using the numeric rating scale, or behavioural indicators of pain scale. The study variables included; mechanical ventilation time, weaning time, ventilation support time, artificial airway time, continuous sedative infusion time, daily dose and frequency of analgesic and sedative drug use, hospital stay, and ICU and hospital mortality, Richmond agitation-sedation scale, bispectral index, numeric rating scale, and behavioural indicators of pain scale measurements. Kruskal Wallis and Chi 2 , and a significance of p<.05 were used. The study included 153 admissions, 75 pre-intervention and 78 post-intervention, with a mean age of 55.7±13 years old, and 67% men. Both groups showed similarities in age, reason for admission, and APACHE. There were non-significant decreases in mechanical ventilation time 4 (1.4-9.2) and 3.2 (1.4-8.1) days, respectively; p= 0.7, continuous sedative infusion time 6 (3-11) and 5 (3-11) days; p= 0.9, length of hospital stay 29 (18-52); 25 (14-41) days; p= 0.1, ICU mortality (8 vs. 5%; p= 0.4), and hospital mortality (10.6 vs. 9.4%: p= 0.8). Daily doses of midazolam and remifentanil decreased 347 (227-479) mg/day; 261 (159-358) mg/day; p= 0.02 and 2175 (1427-3285) mcg/day; 1500 (715-2740) mcg/day; p= 0.02, respectively. There were increases in the use of remifentanil (32% vs. 51%; p= 0.01), dexmedetomidine (0 vs.6%; p= 0.02), dexketoprofen (60 vs. 76%; p= 0.03), and haloperidol (15 vs.28%; p= 0.04). The use of morphine decreased (71 vs. 54%; p= 0.03). There was an increase in the number of measurements and Richmond agitation-sedation scale scores 6 (3-17); 21 (9-39); p< 0.0001, behavioural indicators of pain scale 6 (3-18); 19(8-33); p< 0.001 and numeric rating scale 4 (2-6); 8 (6-17); p< 0.0001. The implementation of a multidisciplinary protocol of systematic evaluation of analgesia and sedation management achieved an improvement in monitoring and adequacy of dose to patient needs, leading to improved outcomes. Copyright © 2015 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-04-01
The bibliography contains citations concerning human factors engineering, anthropometry, and ergonomics as they relate to human comfort in the office and home. Human requirements, including ventilation, temperature control, and lighting, are considered. Research regarding environmental architecture, and engineering, safety, and convenience aspects are discussed. (Contains a minimum of 142 citations and includes a subject term index and title list.)
Kasai, Takatoshi; Narui, Koji; Dohi, Tomotaka; Takaya, Hisashi; Yanagisawa, Naotake; Dungan, George; Ishiwata, Sugao; Ohno, Minoru; Ymaguchi, Tetsu; Momomura, Shin-ichi
2006-09-01
Cheyne-Stokes respiration with central sleep apnea (CSR-CSA) in congestive heart failure (CHF) is generally considered a poor prognostic indicator, but treatment of CSR-CSA using an adaptive servo-ventilation (ASV) device has been developed. This is the first evaluation of its use in the management of CSR-CSA in Japanese CHF patients. Four CHF patients with CSR-CSA that was unresponsive to conventional positive airway pressure (CPAP) underwent 3 nights of polysomnography: baseline, CPAP or bi-level PAP, and on the ASV. The apnea - hypopnea index (AHI) and central-AHI (CAHI) were markedly improved on ASV (AHI 62.7+/-10.1 to 5.9+/-2.2 /h, p=0.0006, CAHI 54.5+/-6.7 to 5.6+/-2.3 /h, p=0.007). In addition, the sleep quality improved significantly on ASV, including arousal index (62.0+/-10.5 to 18.7 +/-6.2 /h, p=0.012), percentage of slow-wave sleep (2.6+/-2.6 to 19.4+/-4.8 %, p=0.042). ASV markedly improved CSR-CSA in patients with CHF. It is a promising treatment for Japanese patients with CHF.
Effects of Zolpidem CR on Sleep and Nocturnal Ventilation in Patients with Heart Failure.
Gatti, Rodrigo C; Burke, Patrick R; Otuyama, Leonardo J; Almeida, Dirceu R; Tufik, Sergio; Poyares, Dalva
2016-08-01
This study aimed to evaluate the effects of zolpidem CR (controlled release) on sleep and nocturnal ventilation in patients with congestive heart failure, a population at risk for insomnia and poor sleep quality. Fifteen patients with heart failure (ischemic cardiomyopathy) and ejection fraction ≤ 45% in NYHA functional class I or II were evaluated with full polysomnography in a placebo-controlled, double-blind, randomized trial. Patients underwent three tests: (1) baseline polysomnography and, after randomization, (2) a new test with zolpidem CR 12.5 mg or placebo, and after 1 week, (3) a new polysomnography, crossing the "medication" used. A 16% increase in total sleep time was found with the use of zolpidem CR and an increase in stage 3 NREM sleep (slow wave sleep). The apnea hypopnea index (AHI) did not change with zolpidem CR even after controlling for supine position; however, a slight but significant decrease was observed in lowest oxygen saturation compared with baseline and placebo conditions (83.60 ± 5.51; 84.43 ± 3.80; 80.71 ± 5.18, P = 0.002). Zolpidem CR improved sleep structure in patients with heart failure, did not change apnea hypopnea index, but slightly decreased lowest oxygen saturation. © 2016 Associated Professional Sleep Societies, LLC.
Oueslati, Ferid; Boone, Jan; Ahmaidi, Said
2016-06-15
The purpose of this study was to investigate the relationships between respiratory muscle endurance, tissue oxygen saturation index dynamics of leg muscle (TSI) and the time to exhaustion (TTE) during high intensity exercise. Eleven males performed a respiratory muscle endurance test, a maximal incremental running field test (8 km h(-1)+0.5 km h(-1) each 60s) and a high-intensity constant speed field test at 90% VO2max. The TSI in vastus lateralis was monitored with near-infrared spectroscopy. The TSI remained steady between 20 and 80% of TTE. Between 80 and 100% of TTE (7.5 ± 6.1%, p<0.05), a significant drop in TSI concomitant with a minute ventilation increase (16 ± 10 l min(-1)) was observed. Moreover, the increase of ventilation was correlated to the drop in TSI (r=0.70, p<0.05). Additionally, respiratory muscle endurance was significantly correlated to TSI time plateau (20-80% TTE) (r=0.83, p<0.05) and to TTE (r=0.95, p<0.001). The results of the present study show that the tissue oxygen saturation plateau might be affected by ventilatory work and that respiratory muscle endurance could be considered as a determinant of performance during heavy exercise. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apte, Michael G.; Norman, Bourassa; Faulkner, David
An improved HVAC system for portable classrooms was specified to address key problems in existing units. These included low energy efficiency, poor control of and provision for adequate ventilation, and excessive acoustic noise. Working with industry, a prototype improved heat pump air conditioner was developed to meet the specification. A one-year measurement-intensive field-test of ten of these IHPAC systems was conducted in occupied classrooms in two distinct California climates. These measurements are compared to those made in parallel in side by side portable classrooms equipped with standard 10 SEER heat pump air conditioner equipment. The IHPAC units were found tomore » work as designed, providing predicted annual energy efficiency improvements of about 36 percent to 42 percent across California's climate zones, relative to 10 SEER units. Classroom ventilation was vastly improved as evidenced by far lower indoor minus outdoor CO2 concentrations. TheIHPAC units were found to provide ventilation that meets both California State energy and occupational codes and the ASHRAE minimum ventilation requirements; the classrooms equipped with the 10 SEER equipment universally did not meet these targets. The IHPAC system provided a major improvement in indoor acoustic conditions. HVAC system generated background noise was reduced in fan-only and fan and compressor modes, reducing the nose levels to better than the design objective of 45 dB(A), and acceptable for additional design points by the Collaborative on High Performance Schools. The IHPAC provided superior ventilation, with indoor minus outdoor CO2 concentrations that showed that the Title 24 minimum ventilation requirement of 15 CFM per occupant was nearly always being met. The opposite was found in the classrooms utilizing the 10 SEER system, where the indoor minus outdoor CO2 concentrations frequently exceeded levels that reflect inadequate ventilation. Improved ventilation conditions in the IHPAC lead to effective removal of volatile organic compounds and aldehydes, on average lowering the concentrations by 57 percent relative to the levels in the 10 SEER classrooms. The average IHPAC to 10 SEER formaldehyde ratio was about 67 percent, indicating only a 33 percent reduction of this compound in indoor air. The IHPAC thermal control system provided less variability in occupied classroom temperature than the 10 SEER thermostats. The average room temperatures in all seasons tended to be slightly lower in the IHPAC classrooms, often below the lower limit of the ASHRAE 55 thermal comfort band. State-wide and national energy modeling provided conservative estimates of potential energy savings by use of the IHPAC system that would provide payback a the range of time far lower than the lifetime of the equipment. Assuming electricity costs of $0.15/kWh, the perclassroom range of savings is from about $85 to $195 per year in California, and about $89 to $250 per year in the U.S., depending upon the city. These modelsdid not include the non-energy benefits to the classrooms including better air quality and acoustic conditions that could lead to improved health and learning in school. Market connection efforts that were part of the study give all indication that this has been a very successful project. The successes include the specification of the IHPAC equipment in the CHPS portable classroom standards, the release of a commercial product based on the standards that is now being installed in schools around the U.S., and the fact that a public utility company is currently considering the addition of the technology to its customer incentive program. These successes indicate that the IHPAC may reach its potential to improve ventilation and save energy in classrooms.« less
Ferrando, Carlos; Soro, Marina; Unzueta, Carmen; Suarez-Sipmann, Fernando; Canet, Jaume; Librero, Julián; Pozo, Natividad; Peiró, Salvador; Llombart, Alicia; León, Irene; India, Inmaculada; Aldecoa, Cesar; Díaz-Cambronero, Oscar; Pestaña, David; Redondo, Francisco J; Garutti, Ignacio; Balust, Jaume; García, Jose I; Ibáñez, Maite; Granell, Manuel; Rodríguez, Aurelio; Gallego, Lucía; de la Matta, Manuel; Gonzalez, Rafael; Brunelli, Andrea; García, Javier; Rovira, Lucas; Barrios, Francisco; Torres, Vicente; Hernández, Samuel; Gracia, Estefanía; Giné, Marta; García, María; García, Nuria; Miguel, Lisset; Sánchez, Sergio; Piñeiro, Patricia; Pujol, Roger; García-Del-Valle, Santiago; Valdivia, José; Hernández, María J; Padrón, Oto; Colás, Ana; Puig, Jaume; Azparren, Gonzalo; Tusman, Gerardo; Villar, Jesús; Belda, Javier
2018-03-01
The effects of individualised perioperative lung-protective ventilation (based on the open-lung approach [OLA]) on postoperative complications is unknown. We aimed to investigate the effects of intraoperative and postoperative ventilatory management in patients scheduled for abdominal surgery, compared with standard protective ventilation. We did this prospective, multicentre, randomised controlled trial in 21 teaching hospitals in Spain. We enrolled patients who were aged 18 years or older, were scheduled to have abdominal surgery with an expected time of longer than 2 h, had intermediate-to-high-risk of developing postoperative pulmonary complications, and who had a body-mass index less than 35 kg/m 2 . Patients were randomly assigned (1:1:1:1) online to receive one of four lung-protective ventilation strategies using low tidal volume plus positive end-expiratory pressure (PEEP): open-lung approach (OLA)-iCPAP (individualised intraoperative ventilation [individualised PEEP after a lung recruitment manoeuvre] plus individualised postoperative continuous positive airway pressure [CPAP]), OLA-CPAP (intraoperative individualised ventilation plus postoperative CPAP), STD-CPAP (standard intraoperative ventilation plus postoperative CPAP), or STD-O 2 (standard intraoperative ventilation plus standard postoperative oxygen therapy). Patients were masked to treatment allocation. Investigators were not masked in the operating and postoperative rooms; after 24 h, data were given to a second investigator who was masked to allocations. The primary outcome was a composite of pulmonary and systemic complications during the first 7 postoperative days. We did the primary analysis using the modified intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT02158923. Between Jan 2, 2015, and May 18, 2016, we enrolled 1012 eligible patients. Data were available for 967 patients, whom we included in the final analysis. Risk of pulmonary and systemic complications did not differ for patients in OLA-iCPAP (110 [46%] of 241, relative risk 0·89 [95% CI 0·74-1·07; p=0·25]), OLA-CPAP (111 [47%] of 238, 0·91 [0·76-1·09; p=0·35]), or STD-CPAP groups (118 [48%] of 244, 0·95 [0·80-1·14; p=0·65]) when compared with patients in the STD-O 2 group (125 [51%] of 244). Intraoperatively, PEEP was increased in 69 (14%) of patients in the standard perioperative ventilation groups because of hypoxaemia, and no patients from either of the OLA groups required rescue manoeuvres. In patients who have major abdominal surgery, the different perioperative open lung approaches tested in this study did not reduce the risk of postoperative complications when compared with standard lung-protective mechanical ventilation. Instituto de Salud Carlos III of the Spanish Ministry of Economy and Competitiveness, and Grants Programme of the European Society of Anaesthesiology. Copyright © 2018 Elsevier Ltd. All rights reserved.
Energy saving effect of desiccant ventilation system using Wakkanai siliceous shale
NASA Astrophysics Data System (ADS)
Nabeshima, Yuki; Togawa, Jun-ya; Nagano, Katsunori; Kazuyo, Tsuzuki
2017-10-01
The nuclear power station accident resulting from the Great East Japan Earthquake disaster has resulted in a constrained electricity supply. However, in this Asian region there is high temperature and high humidity and consequently dehumidification process requires a huge amount of energy. This is the reason for the increasing energy consumption in the residential and commercial sectors. Accordingly, a high efficiency air-conditioning system is needed to be developed. The desiccant ventilation system is effective to reduce energy consumption for the dehumidification process. This system is capable of dehumidifying without dew condensing unlike a conventional air-conditioning system. Then we focused on Wakkanai Siliceous Shale (WSS) as a desiccant material to develop a new desiccant ventilation system. This is low priced, high performance, new type of thing. The aim of this study is to develop a desiccant ventilation unit using the WSS rotor which can be regenerated with low-temperature by numerical calculation. The results of performance prediction of the desiccant unit, indicate that it is possible to regenerate the WSS rotor at low-temperature of between 35 - 45 °C. In addition, we produced an actual measurement for the desiccant unit and air-conditioning unit. This air-conditioning system was capable to reduce roughly 40 % of input energy consumption.
Simulation of thermal environment in a three-layer vinyl greenhouse by natural ventilation control
NASA Astrophysics Data System (ADS)
Jin, Tea-Hwan; Shin, Ki-Yeol; Yoon, Si-Won; Im, Yong-Hoon; Chang, Ki-Chang
2017-11-01
A high energy, efficient, harmonious, ecological greenhouse has been highlighted by advanced future agricultural technology recently. This greenhouse is essential for expanding the production cycle toward growth conditions through combined thermal environmental control. However, it has a negative effect on farming income via huge energy supply expenses. Because not only production income, but operating costs related to thermal load for thermal environment control is important in farming income, it needs studies such as a harmonious ecological greenhouse using natural ventilation control. This study is simulated for energy consumption and thermal environmental conditions in a three-layered greenhouse by natural ventilation using window opening. A virtual 3D model of a three-layered greenhouse was designed based on the real one in the Gangneung area. This 3D model was used to calculate a thermal environment state such as indoor temperature, relative humidity, and thermal load in the case of a window opening rate from 0 to 100%. There was also a heat exchange operated for heating or cooling controlled by various setting temperatures. The results show that the cooling load can be reduced by natural ventilation control in the summer season, and the heat exchange capacity for heating can also be simulated for growth conditions in the winter season.
Complex analysis of energy efficiency in operated high-rise residential building: Case study
NASA Astrophysics Data System (ADS)
Korniyenko, Sergey
2018-03-01
Energy conservation and human thermal comfort enhancement in buildings is a topical issue of modern architecture and construction. The innovative solution of this problem makes it possible to enhance building ecological and maintenance safety, to reduce hydrocarbon fuel consumption, and to improve life standard of people. The requirements to increase of energy efficiency in buildings should be provided at all the stages of building's life cycle that is at the stage of design, construction and maintenance of buildings. The research purpose is complex analysis of energy efficiency in operated high-rise residential building. Many actions for building energy efficiency are realized according to the project; mainly it is the effective building envelope and engineering systems. Based on results of measurements the energy indicators of the building during annual period have been calculated. The main reason of increase in heat losses consists in the raised infiltration of external air in the building through a building envelope owing to the increased air permeability of windows and balcony doors (construction defects). Thermorenovation of the building based on ventilating and infiltration heat losses reduction through a building envelope allows reducing annual energy consumption. Energy efficiency assessment based on the total annual energy consumption of building, including energy indices for heating and a ventilation, hot water supply and electricity supply, in comparison with heating is more complete. The account of various components in building energy balance completely corresponds to modern direction of researches on energy conservation and thermal comfort enhancement in buildings.
Smart Energy Choices Free Up Dollars for Capital Improvements.
ERIC Educational Resources Information Center
Ritchey, David
2003-01-01
Describes several ways to design or renovate school building to save thousand of dollars of energy costs. Considers site design, energy-efficient building envelope, renewable energy systems, lighting and electrical systems, mechanical and ventilation systems, water conservation, and transportation. Describes how to obtain information about the…
heating, ventilation and air conditioning (HVAC) systems, structural insulated panels to improve products and systems. NREL building engineers estimate the combination of advanced products and design Building America program manager George James. "All of the technologies and systems used in this house
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chan, Wanyu R.; Sidheswaran, Meera; sullivan, Douglas
The HZEB research program aims to generate information needed to develop new science-based commercial building ventilation rate (VR) standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. This interim report describes the preliminary results from one HZEB field study on retail stores. The primary purpose of this study is to estimate the whole-building source strengths of contaminant of concerns (COCs). This information is needed to determine the VRs necessary to maintain indoor concentrations of COCs below applicable health guidelines.The goal of this study is to identify contaminants in retail stores that should bemore » controlled via ventilation, and to determine the minimum VRs that would satisfy the occupant health and odor criteria.« less
Cooperation of Horizontal Ground Heat Exchanger with the Ventilation Unit During Summer - Case Study
NASA Astrophysics Data System (ADS)
Romańska-Zapała, Anna; Furtak, Marcin; Dechnik, Mirosław
2017-10-01
Renewable energy sources are used in the modern energy-efficient buildings to improve their energy balance. One of them is used in the mechanical ventilation system ground air heat exchanger (earth-air heat exchanger - EAHX). This solution, right after heat recovery from exhaust air (recuperation), allows the reduction in the energy needed to obtain the desired temperature of supply air. The article presents the results of "in situ" measurements of pipe ground air heat exchanger cooperating with the air handling unit, supporting cooling the building in the summer season, in Polish climatic conditions. The laboratory consists of a ventilation unit intake - exhaust with rotor for which the source of fresh air is the air intake wall and two air intakes field cooperating with the tube with ground air heat exchangers. Selection of the source of fresh air is performed using sprocket with actuators. This system is part of the ventilation system of the Malopolska Laboratory of Energy-Efficient Building (MLBE) building of Cracow University of Technology. The measuring system are, among others, the sensors of parameters of air inlets and outlets of the heat exchanger channels EAHX and weather station that senses the local weather conditions. The measurement data are recorded and archived by the integrated process control system in the building of MLBE. During the study measurements of operating parameters of the ventilation unit cooperating with the selected source of fresh air were performed. Two cases of operation of the system: using EAHX heat exchanger and without it, were analyzed. Potentially the use of ground air heat exchanger in the mechanical ventilation system can reduce the energy demand for heating or cooling rooms by the pre-adjustment of the supply air temperature. Considering the results can be concluded that the continuous use of these exchangers is not optimal. This relationship is appropriate not only on an annual basis for the transitional periods (spring and autumn), but also in individual days in the potentially most favorable periods of work exchanger (summer and winter). Inappropriate operation of the heat exchanger, will lead to a temporary increase in energy consumption for the preparation of the desired air temperature, relative to the fresh air unit which is non-pretreated. For optimal energy system operation: exchanger EAHX - air handling unit, to preserve the most favourable parameters of inlet air to handling unit, there is a need to dynamically adjust the source of fresh air, depending on changing external conditions and the required outlet temperature of central unit (temperature of air forced to the rooms).
Music interventions for mechanically ventilated patients.
Bradt, Joke; Dileo, Cheryl; Grocke, Denise
2010-12-08
Mechanical ventilation often causes major distress and anxiety in patients. Music interventions have been used to reduce anxiety and distress and improve physiological functioning in medical patients; however its efficacy for mechanically ventilated patients needs to be evaluated. To examine the effects of music interventions with standard care versus standard care alone on anxiety and physiological responses in mechanically ventilated patients. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2010, Issue 1), MEDLINE, CINAHL, AMED, EMBASE, PsycINFO, LILACS, Science Citation Index, www.musictherapyworld.net, CAIRSS for Music, Proquest Digital Dissertations, ClinicalTrials.gov, Current Controlled Trials, the National Research Register, and NIH CRISP (all to January 2010). We handsearched music therapy journals and reference lists and contacted relevant experts to identify unpublished manuscripts. There was no language restriction. We included all randomized and quasi-randomized controlled trials that compared music interventions and standard care with standard care alone for mechanically ventilated patients. Two authors independently extracted the data and assessed the methodological quality. Additional information was sought from the trial researchers, when necessary. Results were presented using mean differences for outcomes measured by the same scale and standardized mean differences for outcomes measured by different scales. Post-test scores were used. In cases of significant baseline difference, we used change scores. We included eight trials (213 participants). Music listening was the main intervention used, and seven of the studies did not include a trained music therapist. Results indicated that music listening may be beneficial for anxiety reduction in mechanically ventilated patients; however, these results need to be interpreted with caution due to the small sample size. Findings indicated that listening to music consistently reduced heart rate and respiratory rate, suggesting a relaxation response. No strong evidence was found for blood pressure reduction.Music listening did not improve oxygen saturation level.No studies could be found that examined the effects of music interventions on quality of life, patient satisfaction, post-discharge outcomes, mortality, or cost-effectiveness. Music listening may have a beneficial effect on heart rate, respiratory rate, and anxiety in mechanically ventilated patients. However, the quality of the evidence is not strong. Most studies examined the effects of listening to pre-recorded music. More research is needed on the effects of music offered by a trained music therapist.
Yang, Zhengfei; Liu, Qingyu; Zheng, Guanghui; Liu, Zhifeng; Jiang, Longyuan; Lin, Qing; Chen, Rui; Tang, Wanchun
2017-09-01
A compression-ventilation (C:V) ratio of 30:2 is recommended for adult cardiopulmonary resuscitation (CPR) by the current American Heart Association (AHA) guidelines. However, continuous chest compression (CCC) is an alternative strategy for CPR that minimizes interruption especially when an advanced airway exists. In this study, we investigated the effects of 30:2 mechanical CPR when compared with CCC in combination with regular ventilation in a porcine model. Sixteen male domestic pigs weighing 39±2 kg were utilized. Ventricular fibrillation was induced and untreated for 7 min. The animals were then randomly assigned to receive CCC combined with regular ventilation (CCC group) or 30:2 CPR (VC group). Mechanical chest compression was implemented with a miniaturized mechanical chest compressor. At the same time of beginning of precordial compression, the animals were mechanically ventilated at a rate of 10 breaths-per-minute in the CCC group or with a 30:2 C:V ratio in the VC group. Defibrillation was delivered by a single 150 J shock after 5 min of CPR. If failed to resuscitation, CPR was resumed for 2 min before the next shock. The protocol was stopped if successful resuscitation or at a total of 15 min. The resuscitated animals were observed for 72 h. Coronary perfusion pressure, end-tidal carbon dioxide and carotid blood flow in the VC group were similar to those achieved in the CCC group during CPR. No significant differences were observed in arterial blood gas parameters between two groups at baseline, VF 6 min, CPR 4 min and 30, 120 and 360 min post-resuscitation. Although extravascular lung water index of both groups significantly increased after resuscitation, no distinct difference was found between CCC and VC groups. All animals were successfully resuscitated and survived for 72 h with favorable neurologic outcomes in both groups. However, obviously more numbers of rib fracture were observed in CCC animals in comparison with VC animals. There was no difference in hemodynamic efficacy and gas exchange during and after resuscitation, therefore identical 72 h survival with intact neurologic function was observed in both VC and CCC groups. However, the incidence of rib fracture increases during the mechanical CPR strategy of CCC combined with regular ventilations.
Datta, Debapriya; Foley, Raymond; Wu, Rong; Grady, James; Scalise, Paul
2018-02-01
Malnutrition is common in chronic critically ill patients on prolonged mechanical ventilation (PMV) and may affect weaning. The creatinine height index (CHI), which reflects lean muscle mass, is regarded as the most accurate indicator of malnutrition. The objective of this study was to determine the impact of CHI in comparison with other traditional nutritional indices on successful weaning and survival in patients on PMV after critical illness. Records of 167 patients on PMV following critical illness, admitted for weaning, were reviewed. Parameters studied included age, gender, body mass index (BMI), percentage ideal body weight (%IBW), total protein, albumin, prealbumin, hemoglobin (Hb), and cause of respiratory failure. Number successfully weaned and number discharged alive and time to wean and time to discharge alive were determined from records. The CHI was calculated from 24-hour urine creatinine using a standard formula. Unpaired 2-sample t test was performed to determine the association between the studied nutritional parameters and outcomes. Predictive value of studied parameters for successful weaning and survival was determined by multivariate logistic regression analysis to model dichotomous outcome of successful weaning and survival. Mean age was 68 ± 14 years, 49% were males, 64% were successfully weaned, and 65.8% survived. Total protein, Hb, and CHI had a significant impact on successful weaning. Weight, %IBW, BMI, and CHI had a significant effect on survival. Of all parameters, CHI was most strongly predictive of successful weaning and survival. The CHI is a strong predictor of successful weaning and survival in patients on PMV.
The effect of ephedrine and phenylephrine on BIS values during propofol anaesthesia.
Takizawa, D; Takizawa, E; Miyoshi, S; Kawahara, F; Ito, N; Ishizeki, J; Koizuka, S; Hiraoka, H
2006-08-01
The purpose of this study was to evaluate the effect of ephedrine and phenylephrine on propofol concentrations and bispectral index during propofol anesthesia. General anaesthesia was induced with propofol and was maintained with propofol (4 mg kg-1 h-1) and fentanyl. Vecuronium was used to facilitate the artificial ventilation of the lungs. Patients with systolic blood pressure > 90 mmHg were defined as the control group (n = 16). Patients who had to be treated for larger decreases in arterial blood pressure (systolic blood pressure 60, whereas no patient in the control or phenylephrine groups had bispectral index >60. There were no significant differences in propofol concentrations or cardiac output relative to baseline at 3 or 10 min after the administration of ephedrine or phenylephrine. Ephedrine increases bispectral index values without decreasing propofol concentrations during general anesthesia.
Ghorbani Shahna, Farshid; Bahrami, Abdulrahman; Farasati, Farhad
2012-01-01
Local exhaust ventilation (LEV) systems and integrated collectors were designed and implemented in a mining company in order to control emitted air pollutant from furnaces. The LEV was designed for capture and transition of air pollutants emitted from furnaces to the integrated collectors. The integrated collectors including four high efficiency Stairmand model cyclones for control of particulate matter, a venturi scrubber for control of the fine particles, SO(2) and a part of H(2)S to follow them, and a packed scrubber for treatment of the residual H(2)S and SO(2) were designed. Pollutants concentration were measured to determine system effectiveness. The results showed that the effectiveness of LEV for reducing workplace pollution is 91.83%, 96.32% and 83.67% for dust, SO(2) and H(2)S, respectively. Average removal efficiency of particles by combination of cyclone and venturi scrubber was 98.72%. Average removal efficiency of SO(2) and H(2)S were 95.85% and 47.13% for the venturi scrubber and 68.45% and 92.7% for the packed bed scrubber. The average removal efficiency of SO(2) and H(2)S were increased to 99.1% and 95.95% by the combination of venturi and packed bed scrubbers. According to the results, integrated collectors are a good air pollution control option for industries with economic constraints and ancient technologies.
Plutonium Finishing Plant (PFP) HVAC System Component Index
DOE Office of Scientific and Technical Information (OSTI.GOV)
DICK, J.D.
2000-02-28
The Plutonium Finishing Plant (PFP) WAC System includes sub-systems 25A through 25K. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-005, ''Definition and Means of Maintaining the Ventilation System Confinement Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.'' This document lists safety class and safety significant components for the Heating Ventilation Air Conditioning and specifies the critical characteristics for Commercial Grade Items, as required by HNF-PRO-268 and HNF-PRO-1819. These are the minimum specifications that themore » equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item.« less
[Helicopter transportation of a sedated, mechanically ventilated patient with cervical cord injury].
Kato, Hideya; Nishiwaki, Yuko; Hosoi, Kunihiko; Shiomi, Naoto; Hirata, Masashi
2013-09-01
We report helicopter transportation of a sedated, mechanically ventilated patient with cervical cord injury. A 20-year-old male sustained traumatic injury to the cervical spinal cord during extracurricular activities in a college. On arrival at the hospital, a halo vest was placed on the patient and tracheostomy was performed. On the 38th hospital day, he was transported a distance of 520km by helicopter to a specialized hospital in Fukuoka for medical repatriation. Cabin space was narrow. Since power supply and carrying capacity were limited, battery-driven and portable medical devices were used. In consideration for patient's psychological stress, he was sedated with propofol. RSS (Ramsay sedation scale) scores were recorded to evaluate whether the patient was adequately sedated during helicopter transportation. Prior to transport, we rehearsed the sedation using bispectral index monitoring (BIS) in the hospital to further ensure the patient's safety during the transport.
Schullcke, B; Krueger-Ziolek, S; Gong, B; Jörres, R A; Mueller-Lisse, U; Moeller, K
2017-10-10
Electrical impedance tomography (EIT) has mostly been used in the Intensive Care Unit (ICU) to monitor ventilation distribution but is also promising for the diagnosis in spontaneously breathing patients with obstructive lung diseases. Beside tomographic images, several numerical measures have been proposed to quantitatively assess the lung state. In this study two common measures, the 'Global Inhomogeneity Index' and the 'Coefficient of Variation' were compared regarding their capability to reflect the severity of lung obstruction. A three-dimensional simulation model was used to simulate obstructed lungs, whereby images were reconstructed on a two-dimensional domain. Simulations revealed that minor obstructions are not adequately recognized in the reconstructed images and that obstruction above and below the electrode plane may result in misleading values of inhomogeneity measures. EIT measurements on several electrode planes are necessary to apply these measures in patients with obstructive lung diseases in a promising manner.
Contemporary ventilator management in patients with and at risk of ALI/ARDS.
Chang, Steven Y; Dabbagh, Ousama; Gajic, Ognen; Patrawalla, Amee; Elie, Marie-Carmelle; Talmor, Daniel S; Malhotra, Atul; Adesanya, Adebola; Anderson, Harry L; Blum, James M; Park, Pauline K; Gong, Michelle Ng
2013-04-01
Ventilator practices in patients at risk for acute lung injury (ALI) and ARDS are unclear. We examined factors associated with choice of set tidal volumes (VT), and whether VT < 8 mL/kg predicted body weight (PBW) relates to the development of ALI/ARDS. We performed a secondary analysis of a multicenter cohort of adult subjects at risk of lung injury with and without ALI/ARDS at onset of invasive ventilation. Descriptive statistics were used to describe ventilator practices in specific settings and ALI/ARDS risk groups. Logistic regression analysis was used to determine the factors associated with the use of VT < 8 mL/kg PBW and the relationship of VT to ALI/ARDS development and outcome. Of 829 mechanically ventilated patients, 107 met the criteria for ALI/ARDS at time of intubation, and 161 developed ALI/ARDS after intubation (post-intubation ALI/ARDS). There was significant intercenter variability in initial ventilator settings, and in the incidence of ALI/ARDS and post-intubation ALI/ARDS. The median VT was 7.96 (IQR 7.14-8.94) mL/kg PBW in ALI/ARDS subjects, and 8.45 (IQR 7.50-9.55) mL/kg PBW in subjects without ALI/ARDS (P = .004). VT decreased from 8.40 (IQR 7.38-9.37) mL/kg PBW to 7.97 (IQR 6.90-9.23) mL/kg PBW (P < .001) in those developing post-intubation ALI/ARDS. Among subjects without ALI/ARDS, VT ≥ 8 mL/kg PBW was associated with shorter height and higher body mass index, while subjects with pneumonia were less likely to get ≥ 8 mL/kg PBW. Initial VT ≥ 8 mL/kg PBW was not associated with the post-intubation ALI/ARDS (adjusted odds ratio 1.30, 95% CI 0.74-2.29) or worse outcomes. Post-intubation ALI/ARDS subjects had mortality similar to subjects intubated with ALI/ARDS. Clinicians seem to respond to ALI/ARDS with lower initial VT. Initial VT, however, was not associated with the development of post-intubation ALI/ARDS or other outcomes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Kesheng
2007-08-02
An index in a database system is a data structure that utilizes redundant information about the base data to speed up common searching and retrieval operations. Most commonly used indexes are variants of B-trees, such as B+-tree and B*-tree. FastBit implements a set of alternative indexes call compressed bitmap indexes. Compared with B-tree variants, these indexes provide very efficient searching and retrieval operations by sacrificing the efficiency of updating the indexes after the modification of an individual record. In addition to the well-known strengths of bitmap indexes, FastBit has a special strength stemming from the bitmap compression scheme used. Themore » compression method is called the Word-Aligned Hybrid (WAH) code. It reduces the bitmap indexes to reasonable sizes and at the same time allows very efficient bitwise logical operations directly on the compressed bitmaps. Compared with the well-known compression methods such as LZ77 and Byte-aligned Bitmap code (BBC), WAH sacrifices some space efficiency for a significant improvement in operational efficiency. Since the bitwise logical operations are the most important operations needed to answer queries, using WAH compression has been shown to answer queries significantly faster than using other compression schemes. Theoretical analyses showed that WAH compressed bitmap indexes are optimal for one-dimensional range queries. Only the most efficient indexing schemes such as B+-tree and B*-tree have this optimality property. However, bitmap indexes are superior because they can efficiently answer multi-dimensional range queries by combining the answers to one-dimensional queries.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xiaobing; Malhotra, Mini; Xiong, Zeyu
High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a distributed GSHP system for providing all the space conditioning, outdoor air ventilation, and 100% domestic hot water tomore » the Wilders Grove Solid Waste Service Center of City of Raleigh, North Carolina. This case study is based on the analysis of measured performance data, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning and outdoor air ventilation as the demonstrated GSHP system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GSHP system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation and improving the operational efficiency of the demonstrated GSHP system.« less
Designing for Energy Conservation.
ERIC Educational Resources Information Center
Estes, R. C.
This document is a description of the energy efficient designs for new schools in the Alief Independent School District of Houston, Texas. Exhibit A shows how four major school projects differ from conventional designs. Parameters and designs for heating, ventilating, air conditioning, and lighting are given. Twenty year projected energy costs and…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-16
... for the Commercial HVAC, WH, and Refrigeration Certification Working Group and Announcement of Working... Refrigeration Equipment AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION..., Ventilation, and Air-conditioning (HVAC), Water Heating (WH), and Refrigeration Certification Working Group...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-15
... Meetings for the Commercial HVAC, WH, and Refrigeration Certification Working Group and Announcement of... Refrigeration Equipment AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION..., Ventilation, and Air-conditioning (HVAC), Water Heating (WH), and Refrigeration Certification Working Group...
This School Is for Kids and Community.
ERIC Educational Resources Information Center
American School Board Journal, 1982
1982-01-01
In Avon (Indiana), a community lacking public buildings, a middle school was built with community uses in mind. The swimming pool, gymnasium, and commons area can be blocked off for community use by using floor-to-ceiling gates. The school's heating, ventilating, and air conditioning systems are also energy-efficient. (Author/MLF)
Code of Federal Regulations, 2011 CFR
2011-01-01
... CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Provisions for Commercial Heating, Ventilating, Air-Conditioning and Water Heating Products § 431.174 Additional... commercial HVAC and WH product, as described in § 431.176, and that complies with all requirements imposed by...
Code of Federal Regulations, 2011 CFR
2011-01-01
... CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Provisions for Commercial Heating, Ventilating, Air-Conditioning and Water Heating Products § 431.175 Additional... manufacturer that is not a VICP participant with respect to a particular type of commercial HVAC and WH product...
The influence of opening windows and doors on the natural ventilation rate of a residential building
Increased building energy efficiency is important in reducing national energy use and greenhouse gas emissions. An analysis of air change rates due to door and window openings in a research test house located in a residential environment are presented. These data inform developme...
Determination of indoor exposure levels commonly involves assumptions of fully mixed ventilation conditions. In the effort to determine contaminant levels with efficiency, the nodal approach is common in modeling of the indoor environment. To quantify the transport phenomenon or ...
Coeckelberghs, Ellen; Buys, Roselien; Goetschalckx, Kaatje; Cornelissen, Véronique A; Vanhees, Luc
2016-02-01
Peak exercise capacity is an independent predictor for mortality in patients with coronary artery disease. However, sometimes cardiopulmonary exercise tests are stopped prematurely. Therefore, submaximal exercise measures such as the oxygen uptake efficiency slope have been introduced. The aim of this study was to assess the prognostic value of the oxygen uptake efficiency slope and other exercise parameters, in patients with coronary artery disease. Between 2000 and 2011, 1409 patients with coronary artery disease (age 60.7 ± 9.9 years; 1205 males) underwent cardiopulmonary exercise tests. A maximal effort was not reached in 161 (11.5%) patients. The oxygen uptake efficiency slope was calculated and information on mortality was obtained. Cox proportional hazards regression analyses were used to assess the relation of oxygen uptake efficiency slope and other gas exchange variables with all-cause and cardiovascular mortality. Receiver operating characteristic curve analyses was performed to define optimal cut-off values. During an average follow-up of 7.45 ± 3.20 years (range 0.16-13.95 years), 158 patients died, among which 68 patients for cardiovascular reasons. The oxygen uptake efficiency slope was related to all-cause (hazard ratio: 0.568, p < 0.001) and cardiovascular (hazard ratio: 0.461, p < 0.001) mortality. When significant covariates were entered in the analysis, oxygen uptake efficiency slope remained related to mortality (p < 0.05). When other submaximal exercise parameters were added to the model, oxygen uptake efficiency slope and minute ventilation/carbon dioxide production slope also remained significantly related to mortality. The oxygen uptake efficiency slope is an independent predictor for all-cause and cardiovascular mortality in patients with coronary artery disease, irrespective of a truly maximal effort during cardiopulmonary exercise tests. Furthermore, the oxygen uptake efficiency slope provides prognostic information, complementary to the minute ventilation/carbon dioxide production slope and peak exercise capacity. © The European Society of Cardiology 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hasegawa, H.K.; Staggs, K.J.; Doughty, S.M.
1992-12-01
As a result of a DOE (Tiger Team) Technical Safety Appraisal (November 1990) of the Radiochemical Engineering Development Center (REDC), ORNL Building 7920, a number of fire protection concerns were identified. The primary concern was the perceived loss of ventilation system containment due to the thermal destruction and/or breaching of the prefilters and/or high-efficiency particulate air filters (HEPA `s) and the resultant radioactive release to the external environment. The following report describes the results of an extensive fire test program performed by the Fire Research Discipline (FRD) of the Special Projects Division of Lawrence Livermore National Lab (LLNL) and fundedmore » by ORNL to address these concerns. Full scale mock-ups of a REDC hot cell tank pit, adjacent cubicle pit, and associated ventilation system were constructed at LLNL and 13 fire experiments were conducted to specifically answer the questions raised by the Tiger Team. Our primary test plan was to characterize the burning of a catastrophic solvent spill (kerosene) of 40 liters and its effect on the containment ventilation system prefilters and HEPA filters. In conjunction with ORNL and Lockwood Greene we developed a test matrix that assessed the fire performance of the prefilters and HEPA filters; evaluated the fire response of the fiber reinforced plastic (FRP) epoxy ventilation duct work; the response and effectiveness of the fire protection system, the effect of fire in a cubicle on the vessel off-gas (VOG) elbow, and other fire safety questions.« less
Pinto, Anabela; Almeida, José Pedro; Pinto, Susana; Pereira, João; Oliveira, António Gouveia; de Carvalho, Mamede
2010-11-01
Non-invasive ventilation (NIV) is an efficient method for treating respiratory failure in patients with amyotrophic lateral sclerosis (ALS). However, it requires a process of adaptation not always achieved due to poor compliance. The role of telemonitoring of NIV is not yet established. To test the advantage of using modem communication in NIV of ALS patients. Prospective, single blinded controlled trial. Population and methods According to their residence, 40 consecutive ventilated ALS patients were assigned to one of two groups: a control group (G1, n=20) in which compliance and ventilator parameter settings were assessed during office visits; or an intervention group (G2, n=20) in which patients received a modem device connected to the ventilator. The number of office and emergency room visits and hospital admissions during the entire span of NIV use and the number of parameter setting changes to achieve full compliance were the primary outcome measurements. Demographic and clinical features were similar between the two groups at admission. No difference in compliance was found between the groups. The incidence of changes in parameter settings throughout the survival period with NIV was lower in G2 (p<0.0001) but it was increased during the initial period needed to achieve full compliance. The number of office or emergency room visits and inhospital admissions was significantly lower in G2 (p<0.0001). Survival showed a trend favouring G2 (p=0.13). This study shows that telemonitoring reduces health care utilisation with probable favourable implications on costs, survival and functional status.
Frankenfield, David C; Ashcraft, Christine M; Drasher, Tammy L; Reid, Elizabeth K; Vender, Robert L
2017-05-01
Critically ill patients with cystic fibrosis may be especially sensitive to the negative consequences of overfeeding and underfeeding, yet there is almost no information available about the energy needs of these patients. The purpose of this study was to characterize the metabolic rate of critically ill adult patients with cystic fibrosis requiring mechanical ventilation. This was an observational study in which the resting metabolic rate, oxygen consumption, and carbon dioxide production of adult patients with cystic fibrosis requiring critical care, sedation, and mechanical ventilation were measured with indirect calorimetry. This group was compared with a cohort of adult critical care patients without cystic fibrosis. Twelve patients with cystic fibrosis were identified and measured. These were compared with a control group of 25 critically ill patients. Both groups were underweight (body mass index, 17.4 ± 4.0 kg/m 2 in cystic fibrosis and 18.4 ± 2.3 kg/m 2 in control). Adjusting for differences in age, sex, height, and weight, there was no difference in resting metabolic rate between the cystic fibrosis and control groups (1702 ± 193 vs 1642 ± 194 kcal/d, P = .388). Measured resting metabolic rate matched predicted values 58% of the time in cystic fibrosis and 60% of the time in control. The resting metabolic rate of sedated adult patients with cystic fibrosis being assisted with mechanical ventilation is not different from that of adult critical care patients without cystic fibrosis. In both these underweight groups, accurate prediction of resting metabolic rate is difficult to obtain.
Lista, Gianluca; Bianchi, Silvia; Castoldi, Francesca; Fontana, Paola; Cavigioli, Francesco
2006-01-01
To evaluate the efficacy and safety of bronchoalveolar lavage (BAL) with diluted porcine surfactant in mechanically ventilated term infants with severe acute respiratory distress syndrome (ARDS) due to meconium aspiration syndrome (MAS). Eight consecutive mechanically ventilated term infants with severe ARDS due to MAS underwent BAL with 15 mL/kg of diluted (5.3mg phospholipid/mL) surfactant saline suspension (porcine surfactant [Curosurf]). Treatment was administered slowly in aliquots of 2.5 mL. The mean age of neonates at treatment was 3.5 (range 1-8) hours. Heart rate, systemic blood pressure and oxygen saturation were monitored continuously. Arterial blood gases were measured immediately before treatment, and again at 3 and 6 hours post-treatment. Chest x-rays were taken 6 and 24 hours after treatment. Radiological improvement was evident in all eight patients 6 hours post-treatment. Compared with pre-BAL values, significant improvements (p < 0.05) in mean values for partial pressure of oxygen in arterial blood, partial pressure of carbon dioxide in arterial blood, pH, arterial/alveolar O2 ratio and oxygenation index were documented at 3 and 6 hours after BAL. In all patients, tracheal fluids that had been meconium-stained prior to BAL were clear of meconium after BAL. Only one patient required nitric oxide therapy for transient pulmonary hypertension. No adverse sequelae of treatment occurred during the study. BAL with dilute porcine surfactant administered slowly in 2.5 mL aliquots improved oxygenation and chest x-ray findings, without causing major adverse effects, in mechanically ventilated term infants with ARDS due to MAS.
A Four-Dimensional Computed Tomography Comparison of Healthy vs. Asthmatic Human Lungs
Jahani, Nariman; Choi, Sanghun; Choi, Jiwoong; Haghighi, Babak; Hoffman, Eric A.; Comellas, Alejandro P.; Kline, Joel N.; Lin, Ching-Long
2017-01-01
The purpose of this study was to explore new insights in non-linearity, hysteresis and ventilation heterogeneity of asthmatic human lungs using four-dimensional computed tomography (4D-CT) image data acquired during tidal breathing. Volumetric image data were acquired for 5 non-severe and one severe asthmatic volunteers. Besides 4D-CT image data, function residual capacity and total lung capacity image data during breath-hold were acquired for comparison with dynamic scans. Quantitative results were compared with the previously reported analysis of five healthy human lungs. Using an image registration technique, local variables such as regional ventilation and anisotropic deformation index (ADI) were estimated. Regional ventilation characteristics of non-severe asthmatic subjects were similar to those of healthy subjects, but different from the severe asthmatic subject. Lobar airflow fractions were also well correlated between static and dynamic scans (R2 > 0.84). However, local ventilation heterogeneity significantly increased during tidal breathing in both healthy and asthmatic subjects relative to that of breath-hold perhaps because of airway resistance present only in dynamic breathing. ADI was used to quantify non-linearity and hysteresis of lung motion during tidal breathing. Nonlinearity was greater on inhalation than exhalation among all subjects. However, exhalation nonlinearity among asthmatic subjects was greater than healthy subjects and the difference diminished during inhalation. An increase of non-linearity during exhalation in asthmatic subjects accounted for lower hysteresis relative to that of healthy ones. Thus, assessment of nonlinearity differences between healthy and asthmatic lungs during exhalation may provide quantitative metrics for subject identification and outcome assessment of new interventions. PMID:28372795
Rathgeber, J; Züchner, K; Kietzmann, D; Weyland, W
1995-04-01
Heat and moisture exchangers (HME) are used as artificial noses for intubated patients to prevent tracheo-bronchial or pulmonary damage resulting from dry and cold inspired gases. HME are mounted directly on the tracheal tube, where they collect a large fraction of the heat and moisture of the expired air, adding this to the subsequent inspired breath. The effective performance depends on the water-retention capacity of the HME: the amount of water added to the inspired gas cannot exceed the stored water uptake of the previous breath. This study evaluates the efficiency of four different HME under laboratory and clinical conditions using a new moisture-measuring device. METHODS. In a first step, the absolute efficiency of four different HME (DAR Hygrobac, Gibeck Humid-Vent 2P, Pall BB 22-15 T, and Pall BB 100) was evaluated using a lung model simulating physiological heat and humidity conditions of the upper airways. The model was ventilated with tidal volumes of 500, 1,000, and 1,500 ml and different flow rates. The water content of the ventilated air was determined between tracheal tube and HME using a new high-resolution humidity meter and compared with the absolute water loss of the exhaled air at the gas outlet of a Siemens Servo C ventilator measured with a dew-point hygrometer. Secondly, the moisturizing efficiency was evaluated under clinical conditions in an intensive care unit with 25 intubated patients. Maintaining the ventilatory conditions for each patient, the HME were randomly changed. The humidity data were determined as described above and compared with the laboratory findings. RESULTS AND DISCUSSION. The water content at the respirator outlet is inversely equivalent to the humidity of the inspired gases and represents the water loss from the respiratory tract if the patient is ventilated with dry gases. Moisture retention and heating capacity decreased with higher volumes and higher flow rates. These data are simple to obtain without affecting the patient and can easily be interpreted. It was demonstrated that, compared to physiological conditions, the DAR Hygrobac and Gibeck Humid Vent 2P-HME coated with hygroscopic salts-were able to maintain sufficient inspiratory humidity and heat. The Pall-HME, solely a condensation humidifier, did not meet the physiological requirements.
Mueller, Martina; Wagner, Carol L; Annibale, David J; Knapp, Rebecca G; Hulsey, Thomas C; Almeida, Jonas S
2006-03-01
Approximately 30% of intubated preterm infants with respiratory distress syndrome (RDS) will fail attempted extubation, requiring reintubation and mechanical ventilation. Although ventilator technology and monitoring of premature infants have improved over time, optimal extubation remains challenging. Furthermore, extubation decisions for premature infants require complex informational processing, techniques implicitly learned through clinical practice. Computer-aided decision-support tools would benefit inexperienced clinicians, especially during peak neonatal intensive care unit (NICU) census. A five-step procedure was developed to identify predictive variables. Clinical expert (CE) thought processes comprised one model. Variables from that model were used to develop two mathematical models for the decision-support tool: an artificial neural network (ANN) and a multivariate logistic regression model (MLR). The ranking of the variables in the three models was compared using the Wilcoxon Signed Rank Test. The best performing model was used in a web-based decision-support tool with a user interface implemented in Hypertext Markup Language (HTML) and the mathematical model employing the ANN. CEs identified 51 potentially predictive variables for extubation decisions for an infant on mechanical ventilation. Comparisons of the three models showed a significant difference between the ANN and the CE (p = 0.0006). Of the original 51 potentially predictive variables, the 13 most predictive variables were used to develop an ANN as a web-based decision-tool. The ANN processes user-provided data and returns the prediction 0-1 score and a novelty index. The user then selects the most appropriate threshold for categorizing the prediction as a success or failure. Furthermore, the novelty index, indicating the similarity of the test case to the training case, allows the user to assess the confidence level of the prediction with regard to how much the new data differ from the data originally used for the development of the prediction tool. State-of-the-art, machine-learning methods can be employed for the development of sophisticated tools to aid clinicians' decisions. We identified numerous variables considered relevant for extubation decisions for mechanically ventilated premature infants with RDS. We then developed a web-based decision-support tool for clinicians which can be made widely available and potentially improve patient care world wide.
VA/Q distribution during heavy exercise and recovery in humans: implications for pulmonary edema
NASA Technical Reports Server (NTRS)
Schaffartzik, W.; Poole, D. C.; Derion, T.; Tsukimoto, K.; Hogan, M. C.; Arcos, J. P.; Bebout, D. E.; Wagner, P. D.
1992-01-01
Ventilation-perfusion (VA/Q) inequality has been shown to increase with exercise. Potential mechanisms for this increase include nonuniform pulmonary vasoconstriction, ventilatory time constant inequality, reduced large airway gas mixing, and development of interstitial pulmonary edema. We hypothesized that persistence of VA/Q mismatch after ventilation and cardiac output subside during recovery would be consistent with edema; however, rapid resolution would suggest mechanisms related to changes in ventilation and blood flow per se. Thirteen healthy males performed near-maximal cycle ergometry at an inspiratory PO2 of 91 Torr (because hypoxia accentuates VA/Q mismatch on exercise). Cardiorespiratory variables and inert gas elimination patterns were measured at rest, during exercise, and between 2 and 30 min of recovery. Two profiles of VA/Q distribution behavior emerged during heavy exercise: in group 1 an increase in VA/Q mismatch (log SDQ of 0.35 +/- 0.02 at rest and 0.44 +/- 0.02 at exercise; P less than 0.05, n = 7) and in group 2 no change in VA/Q mismatch (n = 6). There were no differences in anthropometric data, work rate, O2 uptake, or ventilation during heavy exercise between groups. Group 1 demonstrated significantly greater VA/Q inequality, lower vital capacity, and higher forced expiratory flow at 25-75% of forced vital capacity for the first 20 min during recovery than group 2. Cardiac index was higher in group 1 both during heavy exercise and 4 and 6 min postexercise. However, both ventilation and cardiac output returned toward baseline values more rapidly than did VA/Q relationships. Arterial pH was lower in group 1 during exercise and recovery. We conclude that greater VA/Q inequality in group 1 and its persistence during recovery are consistent with the hypothesis that edema occurs and contributes to the increase in VA/Q inequality during exercise. This is supported by observation of greater blood flows and acidosis and, presumably therefore, higher pulmonary vascular pressures in such subjects.
Feng, Jin-Xing; Liu, Xiao-Hong; Huang, Hui-Jun; Yu, Zhen-Zhu; Yang, Hui; He, Liu-Fang
2014-05-01
To study the correlation between end-tidal carbon dioxide (PetCO2) and partial pressure of arterial carbon dioxide (PaCO2) in ventilated newborns. Thirty-one ventilated newborn underwent mainstream PetCO2 monitoring; meanwhile, arterial blood gas analysis was performed. The correlation and consistency between PetCO2 and PaCO2 were assessed. A total of 85 end-tidal and arterial CO2 pairs were obtained from 31 ventilated newborns. The mean PetCO2 (41±10 mm Hg) was significantly lower than the corresponding mean PaCO2 (46±11 mm Hg) (P<0.01). There was a significant positive correlation between PetCO2 and PaCO2 (r=0.92, P<0.01). The overall PetCO2 bias was 5.1±4.3 mm Hg (95% limits of consistency, -3.3 to 13.6 mmHg), and 5% (4/85) of the points were beyond the 95%CI. When the oxygenation index (OI) was less than 300 mm Hg (n=48), there was a significant positive correlation between PetCO2 and PaCO2 (r=0.85, P<0.01); the PetCO2 bias was 5.9±4.3 mm Hg (95% limits of consistency, -2.6 to 14.5 mm Hg), and 4.2% (2/48) of the points were beyond the 95%CI. When the OI was more than 300 mm Hg (n=37), there was also a significant positive correlation between PetCO2 and PaCO2 (r=0.91, P<0.01); the PetCO2 bias was 4.1±4.1 mm Hg (95% limits of consistency, -3.9 to 12.1 mm Hg), and 5% (2/37) of the points were beyond the 95%CI. There is a good correlation and consistency between PetCO2 and PaCO2 in ventilated newborns.
Pulmonary atelectasis during low stretch ventilation: "open lung" versus "lung rest" strategy.
Fanelli, Vito; Mascia, Luciana; Puntorieri, Valeria; Assenzio, Barbara; Elia, Vincenzo; Fornaro, Giancarlo; Martin, Erica L; Bosco, Martino; Delsedime, Luisa; Fiore, Tommaso; Grasso, Salvatore; Ranieri, V Marco
2009-03-01
Limiting tidal volume (VT) may minimize ventilator-induced lung injury (VILI). However, atelectasis induced by low VT ventilation may cause ultrastructural evidence of cell disruption. Apoptosis seems to be involved as protective mechanisms from VILI through the involvement of mitogen-activated protein kinases (MAPKs). We examined the hypothesis that atelectasis may influence the response to protective ventilation through MAPKs. Prospective randomized study. University animal laboratory. Adult male 129/Sv mice. Isolated, nonperfused lungs were randomized to VILI: VT of 20 mL/kg and positive end-expiratory pressure (PEEP) zero; low stretch/lung rest: VT of 6 mL/kg and 8-10 cm H2O of PEEP; low stretch/open lung: VT of 6 mL/kg, two recruitment maneuvers and 14-16 cm H2O of PEEP. Ventilator settings were adjusted using the stress index. Both low stretch strategies equally blunted the VILI-induced derangement of respiratory mechanics (static volume-pressure curve), lung histology (hematoxylin and eosin), and inflammatory mediators (interleukin-6, macrophage inflammatory protein-2 [enzyme-linked immunosorbent assay], and inhibitor of nuclear factor-kB[Western blot]). VILI caused nuclear swelling and membrane disruption of pulmonary cells (electron microscopy). Few pulmonary cells with chromatin condensation and fragmentation were seen during both low stretch strategies. However, although cell thickness during low stretch/open lung was uniform, low stretch/lung rest demonstrated thickening of epithelial cells and plasma membrane bleb formation. Compared with the low stretch/open lung, low stretch/lung rest caused a significant decrease in apoptotic cells (terminal deoxynucleotidyl transferase mediated deoxyuridine-triphosphatase nick end-labeling) and tissue expression of caspase-3 (Western blot). Both low stretch strategies attenuated the activation of MAPKs. Such reduction was larger during low stretch/open lung than during low stretch/lung rest (p < 0.001). Low stretch strategies provide similar attenuation of VILI. However, low stretch/lung rest strategy is associated to less apoptosis and more ultrastructural evidence of cell damage possibly through MAPKs-mediated pathway.
Ke, Hua; Li, Zhan-Kui; Yu, Xi-Ping; Guo, Jin-Zhen
2016-05-01
To study the efficacy of different preparations of budesonide combined with pulmonary surfactant (PS) in improving blood gas levels and preventing bronchopulmonary dysplasia (BPD) in preterm infants with neonatal respiratory distress syndrome (NRDS). A total of 184 preterm infants who developed NRDS within 4 hours after birth were randomly administered with PS + continuous inhalation of budesonide aerosol (continuous aerosol group), PS+budesonide solution (solution group), PS + single inhalation of budesonide aerosol (single aerosol group), and PS alone, with 46 neonates in each group. The changes in arterial blood gas levels, rate of invasive mechanical ventilation after treatment, time of assisted ventilation, rate of repeated use of PS, and the incidence of BPD were compared between the four groups. On the 2nd to 4th day after treatment, pH, PCO2, and oxygenation index (FiO2/PaO2) showed significant differences among the four groups, and the continuous aerosol group showed the most improvements of all indicators, followed by the solution group, single aerosol group, and PS alone group. The continuous aerosol group had a significantly shorter time of assisted ventilation than the other three groups (P<0.05). The solution group had a significantly shorter time of assisted ventilation than the single aerosol and PS alone groups (P<0.05). The rate of invasive mechanical ventilation after treatment, rate of repeated use of PS, and incidence of BPD showed significant differences among the four groups (P<0.05), and the continuous aerosol group had the lowest rates, followed by the solution group. A combination of PS and continuous inhalation of budesonide aerosol has a better efficacy in the treatment of NRDS than a combination of PS and budesonide solution. The difference in reducing the incidence of BDP between the two administration methods awaits further investigation with a larger sample size.
Effect of ARDS Severity and Etiology on Short-Term Outcomes.
El-Haddad, Haitham; Jang, Hyejeong; Chen, Wei; Soubani, Ayman O
2017-09-01
We evaluated the outcome of subjects with ARDS in relation to etiology and severity in a retrospective cohort study of the ARDS Network randomized controlled trials. The primary outcome was 28-d mortality. The secondary outcomes were 60-d mortality and ventilator- and ICU-free days. For severity of ARDS, subjects were stratified according to P aO2 /F IO2 . The etiology of ARDS was classified into sepsis, pneumonia, aspiration, trauma, and others. A total of 2,914 subjects were included in these trials. Outcomes were modeled with multivariable regressions adjusted for baseline covariates, age, sex, race, Acute Physiology and Chronic Health Evaluation III (APACHE III), vasopressor use, modified lung injury score, diabetes mellitus, cancer status, body mass index, pre-ICU location, ICU location, and study. There was no statistically significant difference in 28-d mortality in relation to ARDS severity. Subjects with trauma, compared with other etiologies of ARDS, had significantly lower mortality at 28 d (odds ratio [OR] = 0.47, 95% CI 0.26-0.83, P = .01). Sixty-day mortality was significantly lower for trauma subjects and those with severe ARDS group (OR = 0.5, 95% CI 0.3-0.85, P = .01 and OR = 0.71, 95% CI 0.52-0.98, P = .034, respectively). There were statistically significantly more ICU-free days and ventilator-free days for the aspiration group (OR = 1.09, 95% CI 1.02-1.17, P = .01 and OR = 1.09, 95% CI 1.02-1.16, P = .01, respectively). There was no statistically significant difference in ICU-free days or ventilator-free days in relation to severity of ARDS. Severity of ARDS based on P aO2 /F IO2 did not impact 28-d mortality, ventilator-free days, or ICU-free days. Among the etiologies of ARDS, trauma subjects had the lowest 28- and 60-d mortality, whereas subjects with aspiration had more ICU-free days and ventilator-free days. Copyright © 2017 by Daedalus Enterprises.
Hamada, Satoshi; Takahashi, Ryosuke; Mishima, Michiaki; Chin, Kazuo
2015-11-06
A 70-year-old man (case 1) and a 64-year-old woman (case 2) with multiple system atrophy (MSA) and snoring were admitted for polysomnography. Their awake PaCO2 indicated normocapnia. Apnoea-hypopnoea index (AHI), max transcutaneous carbon dioxide partial pressure (PtcCO2) and ΔPtcCO2 (max PtcCO2 (during sleep)-baseline PtcCO2 (while awake)) were 11.4/h, 63 mm Hg and 18 mm Hg, respectively, in case 1 and 53.1/h, 59 mm Hg and 13 mm Hg, respectively, in case 2. Their sleep-disordered breathing (SDB) was diagnosed as obstructive sleep apnoea with hypoventilation. We thought that variable expiratory positive airway pressure and pressure support ventilation (advanced-adaptive servo ventilation (ASV)) might be favourable for their SDB. Polysomnography after introducing advanced-ASV revealed that AHI, max PtcCO2 and ΔPtcCO2 were 0.2/h, 53 mm Hg and 5 mm Hg, respectively, in case 1 and 1.5/h, 56 mm Hg and 9 mm Hg, respectively, in case 2. Advanced-ASV for treating Cheyne-Stokes breathing may be helpful in SDB in patients with MSA. 2015 BMJ Publishing Group Ltd.
Samson, Nathalie; Praud, Jean-Paul; Quenet, Brigitte; Similowski, Thomas; Straus, Christian
2017-01-18
Sucking, swallowing and breathing are dynamic motor behaviors. Breathing displays features of chaos-like dynamics, in particular nonlinearity and complexity, which take their source in the automatic command of breathing. In contrast, buccal/gill ventilation in amphibians is one of the rare motor behaviors that do not display nonlinear complexity. This study aimed at assessing whether sucking and swallowing would also follow nonlinear complex dynamics in the newborn lamb. Breathing movements were recorded before, during and after bottle-feeding. Sucking pressure and the integrated EMG of the thyroartenoid muscle, as an index of swallowing, were recorded during bottle-feeding. Nonlinear complexity of the whole signals was assessed through the calculation of the noise limit value (NL). Breathing and swallowing always exhibited chaos-like dynamics. The NL of breathing did not change significantly before, during or after bottle-feeding. On the other hand, sucking inconsistently and significantly less frequently than breathing exhibited a chaos-like dynamics. Therefore, the central pattern generator (CPG) that drives sucking may be functionally different from the breathing CPG. Furthermore, the analogy between buccal/gill ventilation and sucking suggests that the latter may take its phylogenetic origin in the gill ventilation CPG of the common ancestor of extant amphibians and mammals. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
The influence of image reconstruction algorithms on linear thorax EIT image analysis of ventilation.
Zhao, Zhanqi; Frerichs, Inéz; Pulletz, Sven; Müller-Lisse, Ullrich; Möller, Knut
2014-06-01
Analysis methods of electrical impedance tomography (EIT) images based on different reconstruction algorithms were examined. EIT measurements were performed on eight mechanically ventilated patients with acute respiratory distress syndrome. A maneuver with step increase of airway pressure was performed. EIT raw data were reconstructed offline with (1) filtered back-projection (BP); (2) the Dräger algorithm based on linearized Newton-Raphson (DR); (3) the GREIT (Graz consensus reconstruction algorithm for EIT) reconstruction algorithm with a circular forward model (GR(C)) and (4) GREIT with individual thorax geometry (GR(T)). Individual thorax contours were automatically determined from the routine computed tomography images. Five indices were calculated on the resulting EIT images respectively: (a) the ratio between tidal and deep inflation impedance changes; (b) tidal impedance changes in the right and left lungs; (c) center of gravity; (d) the global inhomogeneity index and (e) ventilation delay at mid-dorsal regions. No significant differences were found in all examined indices among the four reconstruction algorithms (p > 0.2, Kruskal-Wallis test). The examined algorithms used for EIT image reconstruction do not influence the selected indices derived from the EIT image analysis. Indices that validated for images with one reconstruction algorithm are also valid for other reconstruction algorithms.
The evaluation model of the enterprise energy efficiency based on DPSR.
Wei, Jin-Yu; Zhao, Xiao-Yu; Sun, Xue-Shan
2017-05-08
The reasonable evaluation of the enterprise energy efficiency is an important work in order to reduce the energy consumption. In this paper, an effective energy efficiency evaluation index system is proposed based on DPSR (Driving forces-Pressure-State-Response) with the consideration of the actual situation of enterprises. This index system which covers multi-dimensional indexes of the enterprise energy efficiency can reveal the complete causal chain which includes the "driver forces" and "pressure" of the enterprise energy efficiency "state" caused by the internal and external environment, and the ultimate enterprise energy-saving "response" measures. Furthermore, the ANP (Analytic Network Process) and cloud model are used to calculate the weight of each index and evaluate the energy efficiency level. The analysis of BL Company verifies the feasibility of this index system and also provides an effective way to improve the energy efficiency at last.
Wu, Xiaoyan; Zheng, Ruiqiang; Lin, Hua; Zhuang, Zhiqing; Zhang, Min; Yan, Peixia
2015-10-20
To assess the effect of mehanical ventilation (MV) guided by transpulmonary pressure (Ptp) on respiratory mechanics and gas exchange in severe acute pancreatitis patient with intraabdominal hypertension. Twelve severe acute pancreatitis patient with intraabdominal hypertension and acute respiratory distress syndrome(ARDS) underwent mechanical ventilation were involved from Jan to Dec 2013. PEEP levels were set to achieve a Ptp of 0 to 10 cm of water at end expiration. We also limited tidal volume to keep Ptp at less than 25 cm of water at end inspiration. Respiratory mechanics and gas-exchange were measured. Plat pressure (Pplat) increased and the compliance of chest wall (Ccw) decreased when intraabdominal pressure (IAP) increased. Pplat correlated with IAP positively (r2=0.741 9, P<0.05) and Ccw correlated with IAP negtively (r2=0.722 2, P<0.05), respectively.There were not corrletions between IAP and end-expiratory Ptp (Ptp-e) and end-inspiratory Ptp (Ptp-i) (P>0.05). Compared with baseline, after guiding MV with Ptp, the Level of PEEP (14.6±4.2) cmH2O vs (8.3±2.0) cmH2O, and Ptp-e (1.5±0.5) cmH2O vs (-2.3±1.4) cmH2O increased (P<0.05) and Ptp-i did not increase significantly (P>0.05). Ptp-e correlated with PEEP (r2=0.549, P<0.05) and end-expiratory esophageal pressure (Pes-e) (r2=0.260, P<0.05). Ptp-i correlated with Pplat (r2=0.523, P<0.05) and end-inspiratory esophageal pressure (Pes-i) (r2=0.231, P<0.05), but did not correlate with Tidal volume(VT) (r2=0.052 4, P>0.05). Compared with baseline, lung compliance (CL) (48.1±10.3) cmH2O vs (25.7±6.4) cmH2O and oxygenation index (PaO2/FiO2) (235±48) mmHg vs (160±35) mmHg improved obviously (P<0.05), dead space fraction (VD/VT) (0.48±0.07) vs (0.59±0.06) decreased (P<0.05), but Ccw and respiratory compliance(Cr) didn't improve (P>0.05). Transpulmonary pressure-directed mechanical ventilation in ARDS secondary to severe acute pancreatitis patient with intraabdominal hypertension could not only recruit the collapsed alveoli, improve lung compliance, increase oxygenation index and decrease dead space ventilation but also monitor lung stress to avoid alveoli overinflation, which might be lung protective.
Saadatmand, Vahid; Rejeh, Nahid; Heravi-Karimooi, Majideh; Tadrisi, Sayed Davood; Zayeri, Farid; Vaismoradi, Mojtaba; Jasper, Melanie
2013-07-01
Few studies have been conducted to investigate the effect of nature-based sounds (N-BS) on agitation, anxiety level and physiological signs of stress in patients under mechanical ventilator support. Non-pharmacological nursing interventions such as N-BS can be less expensive and efficient ways to alleviate anxiety and adverse effects of sedative medications in patients under mechanical ventilator support. This study was conducted to identify the effect of the nature-based sounds' intervention on agitation, anxiety level and physiological stress responses in patients under mechanical ventilation support. A randomized placebo-controlled trial design was used to conduct this study. A total of 60 patients aged 18-65 years under mechanical ventilation support in an intensive care unit were randomly assigned to the control and experimental groups. The patients in the intervention group received 90 min of N-BS. Pleasant nature sounds were played to the patients using media players and headphones. Patients' physiological signs were taken immediately before the intervention and at the 30th, 60th, 90th minutes and 30 min after the procedure had finished. The physiological signs of stress assessed were heart rate, respiratory rate, and blood pressure. Data were collected over eight months from Oct 2011 to June 2012. Anxiety levels and agitation were assessed using the Faces Anxiety Scale and Richmond Agitation Sedation Scale, respectively. The experimental group had significantly lower systolic blood pressure, diastolic blood pressure, anxiety and agitation levels than the control group. These reductions increased progressively in the 30th, 60th, 90th minutes, and 30 min after the procedure had finished indicating a cumulative dose effect. N-BS can provide an effective method of decreasing potentially harmful physiological responses arising from anxiety in mechanically ventilated patients. Nurses can incorporate N-BS intervention as a non-pharmacologic intervention into the daily care of patients under mechanical ventilation support in order to reduce their stress and anxiety. Copyright © 2012 Elsevier Ltd. All rights reserved.
Energy saving technologies of the decentralized ventilation of buildings
NASA Astrophysics Data System (ADS)
Mansurov, R. Sh; Rafalskaya, T. A.
2017-11-01
The growing aspiration to energy saving and efficiency of energy leads to necessity to build tight enough buildings. As a result of this the quantity of infiltration air appears insufficient for realization of necessary air exchange in. One of decisions of the given problem is development and application for ventilation of premises of the decentralized forced-air and exhaust systems (DFAES) with recuperative or regenerative heat-exchangers. For an estimation of efficiency of DFAES following basic parameters have been certain: factor of energy saving; factor of efficiency of energy; factor of a heat transfer; factor of an effective utilization of a surface of heat exchange. Were estimated temperature of forced air; actual speed of an air jet on an entrance in a served zone; actual noise level; the charge of external air. Tests of DFAES were spent in natural conditions at which DFAES influenced all set of factors both an external climate, and an internal microclimate of a premise, and also the arrangement on a wind side or behind wind side of a building, influence of surrounding building, fluctuation of temperature of external air is considered. Proceeding from results and the analysis of the lead researches recommendations have been developed for development and manufacture of new sample of DFAES.
The efficiency of CO2 elimination during high-frequency jet ventilation for laryngeal microsurgery.
Biro, P; Eyrich, G; Rohling, R G
1998-07-01
For adequate and safe use of high-frequency jet ventilation (HFJV), reliable monitoring of the PCO2 status and course is necessary. Because of improved handling and performance, recently available transcutaneous PCO2 monitoring devices such as MicroGas 7650 (Kontron Instruments Medical Sensors, Basel, Switzerland) should enable more effective surveillance of CO2 elimination and, subsequently, better control of subglottic HFJV. Adult patients (n = 164) undergoing laryngeal microsurgery during total i.v. anesthesia were assessed. The resulting transcutaneous PCO2 values, as well as the necessary driving pressure settings, were analyzed to define the CO2 elimination capacity of each patient. Therefore, an individual CO2 elimination coefficient (ECCO2) was calculated. The frequency distribution of the obtained ECCO2 values showed a normal distribution with a median at 0.79 and a range between 0.30 and 2.17. A significant difference in the frequency of obstructive lung disease was found between two patient subpopulations separated by the 25th percentile at an ECCO2 value of 0.63. Other co-factors of CO2 elimination during HFJV were age, gender, and body weight, whereas height and ventilation duration were not involved. We conclude that the individual assessment of ECCO2 enables one to find adequate ventilator settings, resulting in lower airway pressure and less cooling and drying of the tracheobronchial mucosa. CO2 elimination during high-frequency jet ventilation can be assessed by calculating the CO2 elimination coefficient (ECCO2) of each patient from the required driving pressure and the resulting transcutaneous CO2 partial pressure. The frequency distribution of ECCO2 in a typical laryngological patient population was analyzed, and a value of 0.63 was found to be a characteristic limit between sufficient and difficult CO2 elimination. The individual assessment of ECCO2 enables one to find adequate ventilator settings, resulting in lower airway pressure and less cooling and drying of the tracheobronchial mucosa.
Wind tunnel study of natural ventilation of building integrated photovoltaics double skin façade
NASA Astrophysics Data System (ADS)
Hudişteanu, Sebastian Valeriu; Popovici, Cătălin George; Cherecheş, Nelu-Cristian
2018-02-01
The paper presents a wind tunnel experimental analysis of a small-scale building model (1:30). The objective of the study is to determine the wind influence on the ventilation of a double skin façade channel (DSF) and the cooling effect over integrated photovoltaic panels. The tests were achieved by conceiving and implementation of an experimental program using a wind tunnel with atmospheric boundary layer. The effect of the wind over the ventilation of the horizontal channels of double skin façades is evaluated for different incident velocities. The results are generalized for the average steady state values of the velocities analysed. The experimental results put in evidence the correlation between the reference wind velocity and the dynamics of the air movement inside the double skin façade. These values are used to determine the convective heat transfer and the cooling effect of the air streams inside the channel upon the integrated photovoltaic panels. The decrease of the photovoltaic panels temperature determines a raise of 11% in efficiency and power generated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apte, Michael G.; Buchanan, Ian S.; Faulkner, David
The primary goals of this research effort are to develop, evaluate, and demonstrate a very practical HVAC system for classrooms that consistently provides classrooms with the quantity of ventilation in current minimum standards, while saving energy, and reducing HVAC-related noise levels. This research is motivated by the public benefits of energy efficiency, evidence that many classrooms are under-ventilated, and public concerns about indoor environmental quality in classrooms. This report presents an interim status update and preliminary findings from energy and indoor environmental quality (IEQ) measurements in sixteen relocatable classrooms in California. The field study includes measurements of HVAC energy use,more » ventilation rates, and IEQ conditions. Ten of the classrooms were equipped with a new HVAC technology and six control classrooms were equipped with a standard HVAC system. Energy use and many IEQ parameters have been monitored continuously, while unoccupied acoustic measurements were measured in one of four planned seasonal measurement campaigns. Continuously monitored data are remotely accessed via a LonWorks{reg_sign} network and stored in a relational database at LBNL. Preliminary results are presented here.« less
Frutos Vázquez, Borja; Olaya Adán, Manuel; Quindós Poncela, Luis Santiago; Sainz Fernandez, Carlos; Fuente Merino, Ismael
2011-04-01
The present paper discusses the results of an empirical study of four approaches to reducing indoor radon concentrations based on depressurization techniques in underground sumps. The experiments were conducted in prototype housing built in an area of Spain where the average radon concentration at a depth of 1 m is 250 kBq m(-3). Sump effectiveness was analysed in two locations: underneath the basement, which involved cutting openings into the foundation, ground storey and roof slabs, and outside the basement walls, which entailed digging a pit alongside the building exterior. The effectiveness of both sumps was likewise tested with passive and forced ventilation methods. The systems proved to be highly efficient, lowering radon levels by 91-99%, except in the solution involving passive ventilation and the outside sump, where radon levels were reduced by 53-55%. At wind speeds of over 8 m/s, however, passive ventilation across an outside sump lowered radon levels by 95% due to a Venturi effect induced drop in pressure. Copyright © 2011 Elsevier Ltd. All rights reserved.
Clearing of ventilating emissions in low temperature environment of plasma
NASA Astrophysics Data System (ADS)
Mansurov, R. Sh; Rafalskaya, T. A.
2017-11-01
The method of high-temperature processing of streams of the ventilating air which is a subject clearing from organic pollutions is developed. Data about its efficiency, including on a number of economic parameters are obtained. Results of work are recommended for use, first of all, by development clearing plasma-thermal reactors (CPTR) for clearing air, especially from toxic substances, and also for large technological clearing installations, containing organic ventilating emissions (OVE). It is created experimental CPTR. Laws of the expiration of a plasma jet in stream of OVE limited by cylindrical walls, water-cooled channel are experimentally investigated. Dependences of a trajectory and long-range the plasma jet blown radially in stream of OVE are received. Heat exchange of stream of OVE with walls of CPTR after blowing a plasma jet is experimentally investigated; dependences of distribution of temperatures on length of a reactor and a thermal stream in a wall of channel of CPTR are received. Are investigated chemical compound of OVE after plasma-thermal clearing, some experimental data by formation of oxides of nitrogen and mono-oxide of carbon during clearing are received.
Zhang, Yong-xing; Wei, Qing-yu; Wang, Juan; Qiao, Ting-hui; Bai, Hong-bing; Cai, Li-na
2007-06-01
To explore the damage of respiratory system in the traffic policemen induced by automobile tyre colloidal particle and its allergenicity. The respiratory system symptoms in 445 traffic policemen working outside their offices and 243 controls were investigated and their pulmonary ventilation function index such as FVC, FEV(1.0), MMF and V(50) were determined. The specific IgE antibody of automobile tyre colloidal particle of their serum was determined and the skin-prick test of automobile tyre colloidal particle antigen was performed. Sixty-six traffic policemen working outside their offices and 5 controls with the positive of IgE antibody among them were detected by nasal mucosa provocation test. Sixty-six traffic policemen working outside their offices with the positive of IgE antibody were determined by Terbutaline inhalation test. The positive rate of respiratory system symptoms of traffic policemen such as cough, stethocatharsis, short breath, nasal obstruction, sneeze and nose running was 38.02%, 27.03%, 20.00%, 23.08%, 27.47%, 32.09% and 34.95% respectively and significantly higher than those of the control with significant difference (P < 0.01) or (P < 0.05). The positive rate of specific IgE antibody of automobile tyre colloidal particle, skin- prick test and nasal mucosa provocation test was 14.51%, 23.73% and 54.55% respectively with significant difference (P < 0.01) and (P < 0.05). The percentage, the actual figure compared with the prediction figure, of the index of pulmonary ventilation function (FVC, FEV(1.0) MMF and V(50)) of traffic policemen were significantly lower than those of the control. Terbutaline inhalation test in 66 positive subjects of specific IgE antibody of automobile tyre colloidal particle was positive in 44 subjects, accounting for 9.67% in all policemen investigated. The automobile tyre colloidal particle is one of etiological factors that induce pulmonary ventilation function damage and could result in allergic asthma of traffic police.
Russell, A; Emmerson, A; Wilkinson, N; Chant, T; Sweet, D; Halliday, H; Holland, B; Davies, E
2001-01-01
OBJECTIVES—The primary objective was to investigate the safety of recombinant human granulocyte colony stimulating factor (rhG-CSF) for the treatment of very low birthweight infants (VLBW) with sepsis and relative neutropenia, specifically with regard to worsening of respiratory distress and thrombocytopenia and all cause mortality. Secondary objectives were to evaluate duration of ventilation, intensive care, and antibiotic use as markers of efficacy. DESIGN—Neonates (⩽ 28 days) in intensive care, with birth weights of 500-1500 g, absolute neutrophil count (ANC) of ⩽ 5 × 109/l, and clinical evidence of sepsis, were randomly assigned to receive either rhG-CSF (10 µg/kg/day) administered intravenously (n = 13), or placebo (n = 15) for a maximum of 14 days, in addition to standard treatment and antibiotics. All adverse events, oxygenation index, incidence of thrombocytopenia, all cause mortality, duration of ventilation, intensive care and antibiotic treatment, and ANC recovery were compared between the two groups. RESULTS—Adverse events and oxygenation index were not increased by, and thrombocytopenia was not attributable to, treatment with rhG-CSF. At 6 and 12 months postmenstrual age, there were significantly fewer deaths in the group receiving rhG-CSF (1/13 v 7/15; p ⩽ 0.038). There was a non-significant trend towards a reduction in duration of ventilation, intensive care, and antibiotic use in the rhG-CSF group. There was a significantly more rapid increase in ANC in the rhG-CSF treated babies (p < 0.001). CONCLUSIONS—In a small randomised placebo controlled trial in a highly selected group of neonates, adjuvant treatment with rhG-CSF increased ANC rapidly, and no treatment related adverse events were identified. Mortality at 6 and 12 months postmenstrual age was significantly lower in the treatment group. A large trial investigating efficacy in a similar group of neonates is warranted. PMID:11320043
NASA Astrophysics Data System (ADS)
Popov, Valeriy; Filatov, Yuriy; Lee, Hee; Golik, Anatoliy
2017-11-01
The paper discusses the problem of the underground mining safety control. The long-term air intake to coal accumulations is reviewed as one of the reasons of endogenous fires during mining. The methods of combating air leaks (inflows) in order to prevent endogenous fires are analyzed. The calculations showing the discrepancy between the design calculations for the mine ventilation, disregarding a number of mining-andgeological and mining-engineering factors, and the actual conditions of mining are given. It is proved that the conversion of operating mines to combined (pressure and exhaust) ventilation system in order to reduce the endogenous fire hazard of underground mining is unreasonable due to impossibility of providing an optimal distribution of aerodynamic pressure in mines. The conversion does not exclude the entry of air into potentially hazardous zones of endogenous fires. The essence of the combined application of positive and negative control methods for the distribution of air pressure is revealed. It consists of air doors installation in easily ventilated airways and installation of pressure equalization chambers equipped with auxiliary fans near the stoppings, working sections and in parallel airways.The effectiveness of the combined application of negative and positive control methods for the air pressure distribution in order to reduce endogenous fire hazard of mining operations is proved.
Children's exposure to indoor air in urban nurseries-part I: CO{sub 2} and comfort assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Branco, P.T.B.S.; Alvim-Ferraz, M.C.M.; Martins, F.G.
2015-07-15
Indoor air quality (IAQ) in nurseries is an emerging case-study. Thus, this study, as the Part I of the larger study “Children's exposure to indoor air in urban nurseries”, aimed to: i) evaluate nurseries’ indoor concentrations of carbon dioxide (CO{sub 2}), a global IAQ indicator, in class and lunch rooms; ii) assess indoor comfort parameters–temperature (T) and relative humidity (RH); and iii) analyse them according to guidelines and references for IAQ, comfort and children's health. Indoor continuous measurements were performed. Non-compliances with guidelines were found in comfort parameters, which could cause discomfort situations and also microbial proliferation. Exceedances in CO{submore » 2} concentrations were also found and they were caused by poor ventilation and high classroom occupation. More efficient ventilation and control of comfort parameters, as well as to reduce occupation by reviewing Portuguese legislation on that matter, would certainly improve IAQ and comfort in nurseries and consequently safeguard children's health. - Highlights: • High occupation and poor ventilation were main determinants of IAQ in nurseries. • T and RH indoor values found in nurseries are likely to cause thermal discomfort. • Building characteristics and an inadequate ventilation determined T and RH values. • High CO{sub 2} concentrations found could indicate accumulation of other air pollutants.« less
Heat transfer variations of bicycle helmets.
Brühwiler, P A; Buyan, M; Huber, R; Bogerd, C P; Sznitman, J; Graf, S F; Rösgen, T
2006-09-01
Bicycle helmets exhibit complex structures so as to combine impact protection with ventilation. A quantitative experimental measure of the state of the art and variations therein is a first step towards establishing principles of bicycle helmet ventilation. A thermal headform mounted in a climate-regulated wind tunnel was used to study the ventilation efficiency of 24 bicycle helmets at two wind speeds. Flow visualization in a water tunnel with a second headform demonstrated the flow patterns involved. The influence of design details such as channel length and vent placement was studied, as well as the impact of hair. Differences in heat transfer among the helmets of up to 30% (scalp) and 10% (face) were observed, with the nude headform showing the highest values. On occasion, a negative role of some vents for forced convection was demonstrated. A weak correlation was found between the projected vent cross-section and heat transfer variations when changing the head tilt angle. A simple analytical model is introduced that facilitates the understanding of forced convection phenomena. A weak correlation between exposed scalp area and heat transfer was deduced. Adding a wig reduces the heat transfer by approximately a factor of 8 in the scalp region and up to one-third for the rest of the head for a selection of the best ventilated helmets. The results suggest that there is significant optimization potential within the basic helmet structure represented in modern bicycle helmets.
Aerobiology in the operating room and its implications for working standards.
Friberg, B; Friberg, S
2005-01-01
Two novel operating room (OR) ventilation concepts, i.e. the upward displacement or thermal convection system and the exponential ultra-clean laminar air flow (LAF) designed to function without extra walls, were evaluated from a bacteriological point of view. The thermal convection system (17 air changes/h) was compared with conventional ventilation (16 air changes/h) with an air inlet at the ceiling and evacuation at floor level. The exponential LAF was compared with the vertical ultra-clean LAF and the horizontal ultra-clean LAF, both with extra side walls. The comparison was made using strictly standardized simulated operations and, except for the horizontal LAF, it was performed in the same OR where the type of ventilation was changed. In the different areas important for surgical asepsis, the thermal system resulted in a twofold to threefold increase in bacterial air and surface counts compared to the conventional system (statistical significance = p < 0.05-0.0001). The bacteriological efficiency of the exponential LAF was equal to the horizontal and vertical LAF units with extra walls in the OR, and all three systems easily fulfilled the criteria for ultra-clean air, i.e. bacteria-carrying particles < 10/m3. In the areas important for surgical asepsis the turbulent ventilation systems yielded highly significant correlation between air and surface contamination (p < 0.02-0.0006). No such correlation existed in the LAF systems.
Tracheal Tube Design and Ventilator-Associated Pneumonia.
Rouzé, Anahita; Jaillette, Emmanuelle; Poissy, Julien; Préau, Sébastien; Nseir, Saad
2017-10-01
Microaspiration of contaminated oropharyngeal and gastric secretions is the main mechanism for ventilator-associated pneumonia (VAP) in critically ill patients. Improving the performance of tracheal tubes in reducing microaspiration is one potential means to prevent VAP. The aim of this narrative review is to discuss recent findings on the impact of tracheal tube design on VAP prevention. Several randomized controlled studies have reported that subglottic secretion drainage (SSD) is efficient in VAP prevention. Meta-analyses have reported conflicting results regarding the impact of SSD on duration of mechanical ventilation, and one animal study raised concern about SSD-related tracheal lesions. However, this measure appears to be cost-effective. Therefore, SSD should probably be used in all patients with expected duration of mechanical ventilation > 48 h. Three randomized controlled trials have shown that tapered-cuff tracheal tubes are not useful to prevent VAP and should probably not be used in critically ill patients. Further studies are required to confirm the promising effects of continuous control of cuff pressure, polyurethane-cuffed, silver-coated, and low-volume low-pressure tracheal tubes. There is moderate evidence for the use of SSD and strong evidence against the use of tapered-cuff tracheal tubes in critically ill patients for VAP prevention. However, more data on the safety and cost-effectiveness of these measures are needed. Other tracheal tube-related preventive measures require further investigation. Copyright © 2017 by Daedalus Enterprises.
Case Studies in Physiology: Ventilation and perfusion in a giraffe-does size matter?
Nyman, Görel; Röken, Bengt; Hedin, Eva-Maria; Hedenstierna, Göran
2016-12-01
The trachea in the giraffe is long but narrow, and dead space ventilation is considered to be of approximately the same size as in other mammals. Less is known about the matching between ventilation and lung blood flow. The lungs in the giraffe are large, up to 1 m high and 0.7 m wide, and this may cause considerable ventilation/perfusion (V A /Q) mismatch due to the influence of gravitational forces, which could lead to hypoxemia. We studied a young giraffe under anesthesia using the multiple inert gas elimination technique to analyze the VA/Q distribution and arterial oxygenation and compared the results with those obtained in other species of different sizes, including humans. V A /Q distribution was broad but unimodal, and the shunt of blood flow through nonventilated lung regions was essentially absent, suggesting no lung collapse. The V A /Q match was as good as in the similarly sized horse and was even comparable to that in smaller sized animals, including rabbit and rat. The match was also similar to that in anesthetized humans. Arterial oxygenation was essentially similar in all studied species. The findings suggest that the efficiency of V A /Q matching is independent of lung size in the studied mammals that vary in weight from less than 1 to more than 400 kg. Copyright © 2016 the American Physiological Society.
Wang, Yan; Wang, Jianrong; Liu, Weiwei; Zhang, Guangliang
2018-03-25
To develop the comprehensive prediction model of acute gastrointestinal injury (AGI) grades of critically ill patients. From April 2015 to November 2015, the binary channel gastrointestinal sounds (GIS) monitor system which has been developed and verified by the research group was used to gather and analyze the GIS of 60 consecutive critically ill patients who were admitted in Critical Care Medicine of Chinese PLA General Hospital. Also, the AGI grades (Grande I(-IIII(, the higher the level, the heavier the gastrointestinal dysfunction) were evaluated. Meanwhile, the clinical data and physiological and biochemical indexes of included patients were collected and recorded daily, including illness severity score (APACHE II( score, consisting of the acute physiology score, age grade and chronic health evaluation), sequential organ failure assessment (SOFA score, including respiration, coagulation, liver, cardioascular, central nervous system and kidney) and Glasgow coma scale (GCS); body mass index, blood lactate and glucose, and treatment details (including mechanical ventilation, sedatives, vasoactive drugs, enteral nutrition, etc.) Then principal component analysis was performed on the significantly correlated GIS (five indexes of gastrointestinal sounds were found to be negatively correlated with AGI grades, which included the number, percentage of time, mean power, maximum power and maximum time of GIS wave from the channel located at the stomach) and clinical factors after standardization. The top 5 post-normalized main components were selected for back-propagation (BP) neural network training, to establish comprehensive AGI grades models of critically ill patients based on the neural network model. The 60 patients aged 19 to 98 (mean 54.6) years and included 42 males (70.0%). There were 22 cases of multiple fractures, 15 cases of severe infection, 7 cases of cervical vertebral fracture, 7 cases of aortic repair, 5 cases of post-toxicosis and 4 cases of cerebral trauma. There were 33 emergency operation, 10 cases of elecoperectomy and 17 cases of drug treatment. There were 56 cases of diabetes(93.3%). Forty-five cases (75.0%) used vasoactive drugs, 37 cases (61.7%) used mechanical ventilation and 44 cases (73.3%) used enteral nutrition. APACHE II( score were 4.0 to 28.0(average 16.8) points. Four clinical factors were significantly positively related with AGI grades, including lactic acid level (r=0.215, P=0.000), SOFA score (r=0.383, P=0.000), the use of vascular active drugs (r=0.611, P=0.000) and mechanical ventilation (r=0.142, P=0.014). In addition to the five indexes of gastric bowel sounds which were found to be negatively correlated with AGI grades, the characteristics of 333 by 9 were composed of these nine indexes with high correlation of AGI grades. Five main components were selected after principal component analysis of these nine correlated indexes. A comprehensive AGI grades model of critically ill patients with a fitting degree of 0.967 3 and an accuracy rate of 82.61% was built by BP artificial neural network. The comprehensive model to classify AGI grades with the GIS is developed, which can help further predicting the classification of AGI grades of critically ill patients.
New Design Tool Can Help Cut building Energy Use
help almost any architect or engineer evaluate passive solar and efficiency design strategies in a tool that enables them to walk through the design process and understand the consequences of design , a feature that tells designers how large of a heating, ventilation and air conditioning (HVAC
Code of Federal Regulations, 2014 CFR
2014-01-01
... conservation standard, or water conservation standard (in the case of commercial prerinse spray valves or... other than electric motors and commercial heating, ventilating, air-conditioning and water heating products. 431.408 Section 431.408 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM...
The Air Pollution Control Technology Verification Center (APCT Center) is operated by RTI International (RTI), in cooperation with EPA's National Risk Management Research Laboratory. The APCT Center conducts verifications of technologies that clean air in ventilation systems, inc...
Variable Pitch Darrieus Water Turbines
NASA Astrophysics Data System (ADS)
Kirke, Brian; Lazauskas, Leo
In recent years the Darrieus wind turbine concept has been adapted for use in water, either as a hydrokinetic turbine converting the kinetic energy of a moving fluid in open flow like an underwater wind turbine, or in a low head or ducted arrangement where flow is confined, streamtube expansion is controlled and efficiency is not subject to the Betz limit. Conventional fixed pitch Darrieus turbines suffer from two drawbacks, (i) low starting torque and (ii) shaking due to cyclical variations in blade angle of attack. Ventilation and cavitation can also cause problems in water turbines when blade velocities are high. Shaking can be largely overcome by the use of helical blades, but these do not produce large starting torque. Variable pitch can produce high starting torque and high efficiency, and by suitable choice of pitch regime, shaking can be minimized but not entirely eliminated. Ventilation can be prevented by avoiding operation close to a free surface, and cavitation can be prevented by limiting blade velocities. This paper summarizes recent developments in Darrieus water turbines, some problems and some possible solutions.
Wang, Yanfu; Jiang, Juncheng; Zhu, Dezhi
2009-07-15
In order to research the fire characteristic under natural ventilation conditions in tunnels with roof openings, full-scale experiment of tunnel fire is designed and conducted. All the experimental data presented in this paper can be further applied for validation of numerical simulation models and reduced-scale experimental results. The physical model of tunnel with roof openings and the mathematical model of tunnel fire are presented in this paper. The tunnel fire under the same conditions as experiment is simulated using CFD software. From the results, it can be seen that most smoke is discharged directly off the tunnel through roof openings, so roof openings are favorable for exhausting smoke. But along with the decrease of smoke temperatures, some smoke may backflow and mix with the smoke-free layer below, which leads to fall in visibility and is unfavorable for personnel evacuation. So it is necessary to research more efficient ways for improving the smoke removal efficiency, such as early fire detection systems, adequate warning signs and setting tunnel cap.
2010-06-01
patient tolerated the SBT, then measurement of respiratory rate (RR), rapid shallow breathing index (RSBI), and negative inspiratory force ( NIF ) were...no deaths in either cohort during the study period. The characteristics of the two groups, along with RR, duration of IBI, NIF , and RSBI calculated... NIF , and RSBI did not differ between groups, and that all subjects who were extubated had weaning parameters predictive of success. To explore the
1981-10-01
measure for Central Nervus System is the Glasgow Cons Score (GCS), a scale of brain and spinal cord injury (Langfitt [1978]), and is itself an additive...concerns directly relating to the injury itself were identified. These were: 1. Ventilation Severity 2 Circulation Severity 3. Central Nervous System ...interacting system within which these concerns represent interacting parts. Most trauma involves only one of these systems , but more than one may be
LOFT. Containment and service building (TAN650). South elevation, details, section. ...
LOFT. Containment and service building (TAN-650). South elevation, details, section. Shows part of duct enclosure, railroad door opening, roof ventilators, shielded personnel entrance, and change room. Section F shows view from west looking toward shielding around airlock door on main floor. Kaiser engineers 6413-11-STEP/LOFT-650-A-9. Date: October 1964. INEEL index code no. 036-650-00-486-122221 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Pan, Jing; Chen, Ming-Wu; Ni, Wen-Quan; Fang, Tao; Zhang, Hui; Chen, Ye; Pan, Jia-Hua
2017-02-01
To explore the clinical efficacy of intratracheal instillation of pulmonary surfactant (PS) combined with budesonide for preventing bronchopulmonary dysplasia (BPD) in very low birth weight (VLBW) infants. Thirty VLBW infants with gestational age <32 weeks who developed neonatal respiratory distress syndrome (NRDS) (grade III-IV) suffering from intrauterine infection were randomly assigned into a PS + budesonide group and a PS alone group. The changes were compared between the two groups in arterial blood gas indexes, oxygenation index (OI), duration of mechanical ventilation, duration of oxygen supplementation, incidence of BPD, mortality rate at 36 weeks corrected gestational age and incidences of other complications except BPD. Compared with the PS alone group, the PS+budesonide group had a lower incidence of BPD, shorter duration of mechanical ventilation and oxygen supplementation (P<0.05). On the 2nd to 6th day after treatment, the PS+budesonide group had higher pH value of arterial blood gas and OI and lower carbon dioxide partial pressure compared with the PS alone group (P<0.05). There were no significant differences in the mortality rate at 36 weeks corrected gestational age and the incidences of other complications except BPD between the two groups (P>0.05). Intratracheal instillation of PS combined with budesonide can effectively reduce the incidence of BPD in VLBW premature infants with severe NRDS.
Xu, Songao; Yu, Huijie; Sun, Hui; Zhu, Xiangyun; Xu, Xiaoqin; Xu, Jun; Cao, Weizhong
2017-01-01
To investigate the efficiency of closed tracheal suction system (CTSS) using novel splash-proof ventilator circuit component on ventilator-associated pneumonia (VAP) and the colonization of multiple-drug resistant bacteria (MDR) in patients undergoing mechanical ventilation (MV) prevention. A prospective single-blinded randomized parallel controlled intervention study was conducted. 330 severe patients admitted to the intensive care unit (ICU) of the First Hospital of Jiaxing from January 2014 to May 2016 were enrolled, and they were divided into open tracheal suction group, closed tracheal suction group, and splash-proof suction group on average by random number table. The patients in the three groups used conventional ventilator circuit component, conventional CTSS, and CTSS with a novel splash-proof ventilator circuit component for MV and sputum suction, respectively. The incidence of VAP, airway bacterial colonization rate, MDR and fungi colonization rate, duration of MV, length of ICU and hospitalization stay, and financial expenditure during hospitalization, as well as the in-hospital prognosis were recorded. After excluding patients who did not meet the inclusion criteria, incomplete data, backed out and so on, 318 patients were enrolled in the analysis finally. Compared with the open tracheal suction group, the total incidence of VAP was decreased in the closed tracheal suction group and splash-proof suction group [20.95% (22/105), 21.90% (23/105) vs. 29.63% (32/108)], but no statistical difference was found (both P > 0.05), and the incidence of VAP infections/1 000 MV days showed the same change tendency (cases: 14.56, 17.35 vs. 23.07). The rate of airway bacterial colonization and the rate of MDR colonization in the open tracheal suction group and splash-proof suction group were remarkably lower than those of closed tracheal suction group [32.41% (35/108), 28.57% (30/105) vs. 46.67% (49/105), 20.37% (22/108), 15.24% (16/105) vs. 39.05% (41/105)] with significantly statistical differences (all P < 0.05). Besides, no significantly statistical difference was found in the fungi colonization rate among open tracheal group, closed tracheal group, and splash-proof suction group (4.63%, 3.81% and 6.67%, respectively, P > 0.05). Compared with the closed tracheal suction group, the duration of MV, the length of ICU and hospitalization stay were shortened in the open tracheal suction group and splash-proof suction group [duration of MV (days): 8.00 (4.00, 13.75), 8.00 (5.00, 13.00) vs. 9.00 (5.00, 16.00); the length of ICU stay (days): 10.00 (6.00, 16.00), 11.00 (7.00, 19.00) vs. 13.00 (7.50, 22.00); the length of hospitalization stay (days): 16.50 (9.25, 32.00), 19.00 (10.50, 32.50) vs. 21.00 (10.00, 36.00)], and financial expenditure during hospitalization was lowered [10 thousand Yuan: 4.95 (3.13, 8.62), 5.47 (3.84, 9.41) vs. 6.52 (3.99, 11.02)] without significantly statistical differences (all P > 0.05). Moreover, no significantly statistical difference was found in the in-hospital prognosis among the three groups. CTSS performed using novel splash-proof ventilator circuit component shared similar advantages in preventing VAP with the conventional CTSS. Meanwhile, it is superior because it prevented the colonization of MDR and high price in the conventional CTSS.Clinical Trail Registration Chinese Clinical Trial Registry, ChiCTR-IOR-16009694.
Fournel, Sébastien; Ouellet, Véronique; Charbonneau, Édith
2017-01-01
Simple Summary The severity of heat stress issues on dairy cows will increase as global warming progresses. Fortunately, major advances in environmental management, including fans, misters, sprinklers, and cooled waterbeds, can attenuate the effects of thermal stress on cow health, production, and reproduction. These cooling systems were, however, tested in subtropical areas and their efficiency in northern regions is uncertain. This article assesses the potential of existing technologies to cool cows in humid continental climates through calculation of heat stress indices. Abstract Heat stress negatively affects the health and performance of dairy cows, resulting in considerable economic losses for the industry. In future years, climate change will exacerbate these losses by making the climate warmer. Physical modification of the environment is considered to be the primary means of reducing adverse effects of hot weather conditions. At present, to reduce stressful heat exposure and to cool cows, dairy farms rely on shade screens and various forms of forced convection and evaporative cooling that may include fans and misters, feed-line sprinklers, and tunnel- or cross-ventilated buildings. However, these systems have been mainly tested in subtropical areas and thus their efficiency in humid continental climates, such as in the province of Québec, Canada, is unclear. Therefore, this study reviewed the available cooling applications and assessed their potential for northern regions. Thermal stress indices such as the temperature-humidity index (THI) were used to evaluate the different cooling strategies. PMID:28468329
NASA Astrophysics Data System (ADS)
Brodny, Jarosław; Tutak, Magdalena
2016-12-01
One of the most dangerous and most commonly present risks in hard coal mines is methane hazard. During exploitation by longwall system with caving, methane is emitted to mine heading from the mined coal and coal left in a pile. A large amount of methane also flows from neighboring seams through cracks and fissures formed in rock mass. In a case of accumulation of explosive methane concentration in goaf zone and with appropriate oxygen concentration and occurrence of initials (e.g. spark or endogenous fire), it may come to the explosion of this gas. In the paper there are presented results of numerical analysis of mixture of air and methane streams flow through the real heading system of a mine, characterized by high methane hazard. The aim of the studies was to analyze the ventilation system of considered heading system and determination of braking zones in goaf zone, in which dangerous and explosive concertation of methane can occur with sufficient oxygen concentration equal to at least 12%. Determination of position of these zones is necessary for the selection of appropriate parameters of the ventilation system to ensure safety of the crew. Analysis of the scale of methane hazard allows to select such a ventilation system of exploitation and neighboring headings that ensures chemical composition of mining atmosphere required by regulation, and required efficiency of methane drainage. The obtained results clearly show that numerical methods, combined with the results of tests in real conditions can be successfully used for the analysis of variants of processes related to ventilation of underground mining, and also in the analysis of emergency states.
Alsved, M; Civilis, A; Ekolind, P; Tammelin, A; Andersson, A Erichsen; Jakobsson, J; Svensson, T; Ramstorp, M; Sadrizadeh, S; Larsson, P-A; Bohgard, M; Šantl-Temkiv, T; Löndahl, J
2018-02-01
To evaluate three types of ventilation systems for operating rooms with respect to air cleanliness [in colony-forming units (cfu/m 3 )], energy consumption and comfort of working environment (noise and draught) as reported by surgical team members. Two commonly used ventilation systems, vertical laminar airflow (LAF) and turbulent mixed airflow (TMA), were compared with a newly developed ventilation technique, temperature-controlled airflow (T c AF). The cfu concentrations were measured at three locations in an operating room during 45 orthopaedic procedures: close to the wound (<40cm), at the instrument table and peripherally in the room. The operating team evaluated the comfort of the working environment by answering a questionnaire. LAF and T c AF, but not TMA, resulted in less than 10cfu/m 3 at all measurement locations in the room during surgery. Median values of cfu/m 3 close to the wound (250 samples) were 0 for LAF, 1 for T c AF and 10 for TMA. Peripherally in the room, the cfu concentrations were lowest for T c AF. The cfu concentrations did not scale proportionally with airflow rates. Compared with LAF, the power consumption of T c AF was 28% lower and there was significantly less disturbance from noise and draught. T c AF and LAF remove bacteria more efficiently from the air than TMA, especially close to the wound and at the instrument table. Like LAF, the new T c AF ventilation system maintained very low levels of cfu in the air, but T c AF used substantially less energy and provided a more comfortable working environment than LAF. This enables energy savings with preserved air quality. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Wang, Xinyan; Shi, Tingming; Lu, Wei; Qin, Shaoxian; Liu, Yuewei; Tao, Ying; Zhang, Hongge; Chen, Weihong
2015-01-01
The objective of this study was to investigate the aspiratory resistance, filtration penetration and their influence factors of N95 filtering-facepiece respirators used widely in China. The total of 6 brands and 21 models of N95 filtering-facepiece respirators which are certified and big sales on the market. The aspiratory resistance and filtration efficiency filter penetration were measured while air pump ran from 10 L/min to 100 L/min using differential pressure gauge and the PortaCount, respectively. The filtration penetrations for 2 of the 21 models were lower than 95%, and the qualified rate for all models was 90.47%. The filtration penetrations gradually decreased when ventilation flow of air pump increased. The negative correlation was observed between filtration penetration and ventilation flow (r(2) = 0.711, P < 0.05). The resistances of all 21 models of N95 respirators met the requirements of the national standard. The aspiratory resistance started to elevate with the increasing of ventilation flow, and a positive correlation between both (r(2) = 0.878, P < 0.05). Significant differences of filtration penetration and aspiratory resistance were observed among between different brands (P < 0.05) although no differences of filtration penetration existed among different models of one brand (P > 0.05). But the differences of the aspiratory resistance among different models of one brand were statistically significant (P < 0.05). The aspiratory resistances of all N95 filtering-facepiece respirators used in this study met the requirements of the national standard. And the qualified ratio of filtration penetration of all models was higher than 90%. The influencing factors of aspiratory resistance included materials, size and ventilation flow. And influencing factors for filtration penetration were materials and ventilation flow.
Nadeau, Mathieu; Sage, Michael; Kohlhauer, Matthias; Mousseau, Julien; Vandamme, Jonathan; Fortin-Pellerin, Etienne; Praud, Jean-Paul; Tissier, Renaud; Walti, Herve; Micheau, Philippe
2017-12-01
Recent preclinical studies have shown that therapeutic hypothermia induced in less than 30 min by total liquid ventilation (TLV) strongly improves the survival rate after cardiac arrest. When the lung is ventilated with a breathable perfluorocarbon liquid, the inspired perfluorocarbon allows us to control efficiently the cooling process of the organs. While TLV can rapidly cool animals, the cooling speed in humans remains unknown. The objective is to predict the efficiency and safety of ultrafast cooling by TLV in adult humans. It is based on a previously published thermal model of ovines in TLV and the design of a direct optimal controller to compute the inspired perfluorocarbon temperature profile. The experimental results in an adult sheep are presented. The thermal model of sheep is subsequently projected to a human model to simulate the optimal hypothermia induction and its sensitivity to physiological parameter uncertainties. The results in the sheep showed that the computed inspired perfluorocarbon temperature command can avoid arterial temperature undershoot. The projection to humans revealed that mild hypothermia should be ultrafast (reached in fewer than 3 min (-72 °C/h) for the brain and 20 min (-10 °C/h) for the entire body). The projection to human model allows concluding that therapeutic hypothermia induction by TLV can be ultrafast and safe. This study is the first to simulate ultrafast cooling by TLV in a human model and is a strong motivation to translate TLV to humans to improve the quality of life of postcardiac arrest patients.
NASA Astrophysics Data System (ADS)
Fadeyi, M. O.; Weschler, C. J.; Tham, K. W.
This study examined the impact of recirculation rates (7 and 14 h -1), ventilation rates (1 and 2 h -1), and filtration on secondary organic aerosols (SOAs) generated by ozone of outdoor origin reacting with limonene of indoor origin. Experiments were conducted within a recirculating air handling system that serviced an unoccupied, 236 m 3 environmental chamber configured to simulate an office; either no filter, a new filter or a used filter was located downstream of where outdoor air mixed with return air. For otherwise comparable conditions, the SOA number and mass concentrations at a recirculation rate of 14 h -1 were significantly smaller than at a recirculation rate of 7 h -1. This was due primarily to lower ozone concentrations, resulting from increased surface removal, at the higher recirculation rate. Increased ventilation increased outdoor-to-indoor transport of ozone, but this was more than offset by the increased dilution of SOA derived from ozone-initiated chemistry. The presence of a particle filter (new or used) strikingly lowered SOA number and mass concentrations compared with conditions when no filter was present. Even though the particle filter in this study had only 35% single-pass removal efficiency for 100 nm particles, filtration efficiency was greatly amplified by recirculation. SOA particle levels were reduced to an even greater extent when an activated carbon filter was in the system, due to ozone removal by the carbon filter. These findings improve our understanding of the influence of commonly employed energy saving procedures on occupant exposures to ozone and ozone-derived SOA.
Lu, Yehu; Wei, Fanru; Lai, Dandan; Shi, Wen; Wang, Faming; Gao, Chuansi; Song, Guowen
2015-08-01
Personal cooling systems (PCS) have been developed to mitigate the impact of severe heat stress for humans working in hot environments. It is still a great challenge to develop PCSs that are portable, inexpensive, and effective. We studied the performance of a new hybrid PCS incorporating both ventilation fans and phase change materials (PCMs). The cooling efficiency of the newly developed PCS was investigated on a sweating manikin in two hot conditions: hot humid (HH, 34°C, 75% RH) and hot dry (HD, 34°C, 28% RH). Four test scenarios were selected: fans off with no PCMs (i.e., Fan-off, the CONTROL), fans on with no PCMs (i.e., Fan-on), fans off with fully solidified PCMs (i.e., PCM+Fan-off), and fans on with fully solidified PCMs (i.e., PCM+Fan-on). It was found that the addition of PCMs provided a 54∼78min cooling in HH condition. In contrast, the PCMs only offered a 19-39min cooling in HD condition. In both conditions, the ventilation fans greatly enhanced the evaporative heat loss compared with Fan-off. The hybrid PCS (i.e., PCM+Fan-on) provided a continuous cooling effect during the three-hour test and the average cooling rate for the whole body was around 111 and 315W in HH and HD conditions, respectively. Overall, the new hybrid PCS may be an effective means of ameliorating symptoms of heat stress in both hot-humid and hot-dry environments. Copyright © 2015 Elsevier Ltd. All rights reserved.
Santos, Arnoldo; Gomez-Peñalver, Eva; Monge-Garcia, M Ignacio; Retamal, Jaime; Borges, João Batista; Tusman, Gerardo; Hedenstierna, Goran; Larsson, Anders; Suarez-Sipmann, Fernando
2017-11-01
To compare the effects of two lung-protective ventilation strategies on pulmonary vascular mechanics in early acute respiratory distress syndrome. Experimental study. University animal research laboratory. Twelve pigs (30.8 ± 2.5 kg). Acute respiratory distress syndrome was induced by repeated lung lavages and injurious mechanical ventilation. Thereafter, animals were randomized to 4 hours ventilation according to the Acute Respiratory Distress Syndrome Network protocol or to an open lung approach strategy. Pressure and flow sensors placed at the pulmonary artery trunk allowed continuous assessment of pulmonary artery resistance, effective elastance, compliance, and reflected pressure waves. Respiratory mechanics and gas exchange data were collected. Acute respiratory distress syndrome led to pulmonary vascular mechanics deterioration. Four hours after randomization, pulmonary vascular mechanics was similar in Acute Respiratory Distress Syndrome Network and open lung approach: resistance (578 ± 252 vs 626 ± 153 dyn.s/cm; p = 0.714), effective elastance, (0.63 ± 0.22 vs 0.58 ± 0.17 mm Hg/mL; p = 0.710), compliance (1.19 ± 0.8 vs 1.50 ± 0.27 mL/mm Hg; p = 0.437), and reflection index (0.36 ± 0.04 vs 0.34 ± 0.09; p = 0.680). Open lung approach as compared to Acute Respiratory Distress Syndrome Network was associated with improved dynamic respiratory compliance (17.3 ± 2.6 vs 10.5 ± 1.3 mL/cm H2O; p < 0.001), driving pressure (9.6 ± 1.3 vs 19.3 ± 2.7 cm H2O; p < 0.001), and venous admixture (0.05 ± 0.01 vs 0.22 ± 0.03, p < 0.001) and lower mean pulmonary artery pressure (26 ± 3 vs 34 ± 7 mm Hg; p = 0.045) despite of using a higher positive end-expiratory pressure (17.4 ± 0.7 vs 9.5 ± 2.4 cm H2O; p < 0.001). Cardiac index, however, was lower in open lung approach (1.42 ± 0.16 vs 2.27 ± 0.48 L/min; p = 0.005). In this experimental model, Acute Respiratory Distress Syndrome Network and open lung approach affected pulmonary vascular mechanics similarly. The use of higher positive end-expiratory pressures in the open lung approach strategy did not worsen pulmonary vascular mechanics, improved lung mechanics, and gas exchange but at the expense of a lower cardiac index.
Moyson, Sofie; Liew, Hon Jung; Diricx, Marjan; Sinha, Amit Kumar; Blust, Ronny; De Boeck, Gudrun
2015-01-01
In the present study, the combined effects of hypoxia and nutritional status were examined in common carp (Cyprinus carpio), a relatively hypoxia tolerant cyprinid. Fish were either fed or fasted and were exposed to hypoxia (1.5-1.8mg O2L(-1)) at or slightly above their critical oxygen concentration during 1, 3 or 7days followed by a 7day recovery period. Ventilation initially increased during hypoxia, but fasted fish had lower ventilation frequencies than fed fish. In fed fish, ventilation returned to control levels during hypoxia, while in fasted fish recovery only occurred after reoxygenation. Due to this, C. carpio managed, at least in part, to maintain aerobic metabolism during hypoxia: muscle and plasma lactate levels remained relatively stable although they tended to be higher in fed fish (despite higher ventilation rates). However, during recovery, compensatory responses differed greatly between both feeding regimes: plasma lactate in fed fish increased with a simultaneous breakdown of liver glycogen indicating increased energy use, while fasted fish seemed to economize energy and recycle decreasing plasma lactate levels into increasing liver glycogen levels. Protein was used under both feeding regimes during hypoxia and subsequent recovery: protein levels reduced mainly in liver for fed fish and in muscle for fasted fish. Overall, nutritional status had a greater impact on energy reserves than the lack of oxygen with a lower hepatosomatic index and lower glycogen stores in fasted fish. Fasted fish transiently increased Na(+)/K(+)-ATPase activity under hypoxia, but in general ionoregulatory balance proved to be only slightly disturbed, showing that sufficient energy was left for ion regulation. Copyright © 2014 Elsevier Inc. All rights reserved.
Parikh, Nehal A.; Kennedy, Kathleen A.; Lasky, Robert E.; McDavid, Georgia E.; Tyson, Jon E.
2012-01-01
Objective To test the hypothesis that high-risk ventilator-dependent extremely low birth weight (ELBW; BW ≤1000g) infants treated with seven days of hydrocortisone will have larger total brain tissue volumes than placebo treated infants. Study design A predetermined sample size of 64 ELBW infants, between 10 to 21 days old and ventilator-dependent with a respiratory index score ≥2, were randomized to systemic hydrocortisone (17 mg/kg cumulative dose) or saline placebo. Primary outcome was total brain tissue volume. Volumetric MRI was performed at 38 weeks postmenstrual age; brain tissue regions were segmented and quantified automatically with a high degree of accuracy and nine structures were segmented manually. All analyses of regional brain volumes were adjusted by postmenstrual age at MRI scan. Results The study groups were similar at baseline and eight infants died in each arm. Unadjusted total brain tissue volume (mean±SD) in the hydrocortisone (N=23) and placebo treated infants (N=21) was 272±40.3 cm3 and 277.8±59.1 cm3, respectively (adjusted mean difference: 6.35 cm3 (95% CI: (−20.8, 32.5); P=0.64). Three of the 31 hydrocortisone treated infants and five of the 33 placebo treated infants survived without severe BPD (RR 0.62, 95% CI: 0.13, 2.66; P=0.49). No significant differences were noted in pre-specified secondary outcomes of regional structural volumes or days on respiratory support. No adverse effects of hydrocortisone were observed. Conclusions Low dose hydrocortisone in high-risk ventilator-dependent infants after a week of age had no discernible effect on regional brain volumes or pulmonary outcomes prior to NICU discharge. PMID:23140612
Kheterpal, Sachin; Healy, David; Aziz, Michael F; Shanks, Amy M; Freundlich, Robert E; Linton, Fiona; Martin, Lizabeth D; Linton, Jonathan; Epps, Jerry L; Fernandez-Bustamante, Ana; Jameson, Leslie C; Tremper, Tyler; Tremper, Kevin K
2013-12-01
Research regarding difficult mask ventilation (DMV) combined with difficult laryngoscopy (DL) is extremely limited even though each technique serves as a rescue for one another. Four tertiary care centers participating in the Multicenter Perioperative Outcomes Group used a consistent structured patient history and airway examination and airway outcome definition. DMV was defined as grade 3 or 4 mask ventilation, and DL was defined as grade 3 or 4 laryngoscopic view or four or more intubation attempts. The primary outcome was DMV combined with DL. Patients with the primary outcome were compared to those without the primary outcome to identify predictors of DMV combined with DL using a non-parsimonious logistic regression. Of 492,239 cases performed at four institutions among adult patients, 176,679 included a documented face mask ventilation and laryngoscopy attempt. Six hundred ninety-eight patients experienced the primary outcome, an overall incidence of 0.40%. One patient required an emergent cricothyrotomy, 177 were intubated using direct laryngoscopy, 284 using direct laryngoscopy with bougie introducer, 163 using videolaryngoscopy, and 73 using other techniques. Independent predictors of the primary outcome included age 46 yr or more, body mass index 30 or more, male sex, Mallampati III or IV, neck mass or radiation, limited thyromental distance, sleep apnea, presence of teeth, beard, thick neck, limited cervical spine mobility, and limited jaw protrusion (c-statistic 0.84 [95% CI, 0.82-0.87]). DMV combined with DL is an infrequent but not rare phenomenon. Most patients can be managed with the use of direct or videolaryngoscopy. An easy to use unweighted risk scale has robust discriminating capacity.
The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea.
Javaheri, Shahrokh; Goetting, Mark G; Khayat, Rami; Wylie, Paul E; Goodwin, James L; Parthasarathy, Sairam
2011-12-01
This study was conducted to evaluate the therapeutic performance of a new auto Servo Ventilation device (Philips Respironics autoSV Advanced) for the treatment of complex central sleep apnea (CompSA). The features of autoSV Advanced include an automatic expiratory pressure (EPAP) adjustment, an advanced algorithm for distinguishing open versus obstructed airway apnea, a modified auto backup rate which is proportional to subject's baseline breathing rate, and a variable inspiratory support. Our primary aim was to compare the performance of the advanced servo-ventilator (BiPAP autoSV Advanced) with conventional servo-ventilator (BiPAP autoSV) in treating central sleep apnea (CSA). A prospective, multicenter, randomized, controlled trial. Five sleep laboratories in the United States. Thirty-seven participants were included. All subjects had full night polysomnography (PSG) followed by a second night continuous positive airway pressure (CPAP) titration. All had a central apnea index ≥ 5 per hour of sleep on CPAP. Subjects were randomly assigned to 2 full-night PSGs while treated with either the previously marketed autoSV, or the new autoSV Advanced device. The 2 randomized sleep studies were blindly scored centrally. Across the 4 nights (PSG, CPAP, autoSV, and autoSV Advanced), the mean ± 1 SD apnea hypopnea indices were 53 ± 23, 35 ± 20, 10 ± 10, and 6 ± 6, respectively; indices for CSA were 16 ± 19, 19 ± 18, 3 ± 4, and 0.6 ± 1. AutoSV Advanced was more effective than other modes in correcting sleep related breathing disorders. BiPAP autoSV Advanced was more effective than conventional BiPAP autoSV in the treatment of sleep disordered breathing in patients with CSA.
[Intensive care unit profesionals's knowledge about non invasive ventilation comparative analysis].
Raurell-Torredà, M; Argilaga-Molero, E; Colomer-Plana, M; Ruiz-García, T; Galvany-Ferrer, A; González-Pujol, A
2015-01-01
The literature highlights the lack of noninvasive ventilation (NIV) protocols and the variability of the knowledge of NIV between intensive care units (ICU) and hospitals, so we want to compare NIV nurses's Knowledge from 4 multipurpose ICU and one surgical ICU. Multicenter, crosscutting, descriptive study in three university hospitals. The survey instrument was validated in a pilot test, and the calculated Kappa index was 0.9. Returning a completed survey is an indication of informed consent. Analysis by Chi square test. 117 responded (65%) nurses, 11±9.7 years of experience in ICU and 9.2±7.2 in use of NIV. One of the multipurpose ICU, was initiated NIV an average of 6 years later than the others (95% CI [3.3 to 8.6], P<.001). Only 23.1% of nurses would place a non-vented mask (with no exhalation port) by conventional ventilator, the rest any kind of face mask. 12.7% believed that the mask must be adjusted to the "2-finger" fit while 29% would seal the mask to the patient's face and cover the mask opening where air escapes to facilitate patient/ventilator synchronization. In the surgical ICU agitation identifies mostly as a complication of NIV compared with multipurpose UCIs (31.6% vs 1.8%, P<.001). 56.4% of nurses do not consider respiratory physiotherapy as nursing care, with no difference between units. Knowledge about types of interface is very dependent on the material of the unit. More training for complications of NIV as agitation and handling secretions it is necessary. Copyright © 2014 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
Kan, Mee-Nin; Chang, Han-Hsin; Sheu, Woei-Fen; Cheng, Chien-Hsiang; Lee, Bor-Jen; Huang, Yi-Chia
2003-01-01
Background There is very little information on what is considered an adequate energy intake for mechanically ventilated, critically ill patients. The purpose of the present study was to determine this energy requirement by making use of patients' nutritional status. Methods The study was conducted in a multidisciplinary intensive care unit of Taichung Veterans General Hospital, Taiwan. Patients were hemodynamically stable and not comatose, and were requiring at least 7 days of mechanical ventilation. Fifty-four patients successfully completed this study. The resting energy expenditure was measured using indirect calorimetry. The total energy requirement was considered 120% of the measured energy expenditure. The daily nutrient intake was recorded. Nutritional status was assessed using single and multiple parameters, nitrogen balance, and medical records, and was performed within 24 hours of admission and after 7 days in the intensive care unit. Results Fifteen patients were being underfed (<90% of total energy requirement), 20 patients were in the appropriate feeding (AF) group (within ± 10% of total energy requirement), and 19 patients received overfeeding (>110% of total energy requirement). Patients in the underfeeding group received only 68.3% of their energy requirement, while the overfeeding group patients received up to 136.5% of their required calories. Only patients in the AF group had a positive nitrogen balance (0.04 ± 5.1) on day 7. AF group patients had a significantly higher Nutritional Risk Index value at day 7 than at day 1. Conclusion AF patients had more improvement in nutritional status than patients in the other feeding groups. To provide at least 120% of the resting energy expenditure seemed adequate to meet the caloric energy needs of hemodynamically stable, mechanically ventilated, critically ill patients. PMID:12974978
Okuyama, M; Kato, S; Sato, S; Okazaki, J; Kitamura, Y; Ishikawa, T; Sato, Y; Isono, S
2018-01-01
Difficult mask ventilation is common and is known to be associated with sleep-disordered breathing (SDB). It is our hypothesis that the incidence of expiratory retropalatal (RP) airway closure (primary outcome) during nasal positive pressure ventilation (PPV) is more frequent in patients with SDB (apnea hypopnea index ≥5 h -1 ) than non-SDB subjects. The severity of SDB was assessed before surgery using a portable sleep monitor. In anaesthetized and paralysed patients with (n=11) and without SDB (n=9), we observed the behaviour of the RP airway endoscopically during nasal PPV with the mouth closed and determined the dynamic RP closing pressure, which was defined as the highest airway pressure above which the RP airway closure was reversed. The static RP closing pressure was obtained during cessation of mechanical ventilation in patients with dynamic RP closure during nasal PPV. The expiratory RP airway closure accompanied by expiratory flow limitation occurred more frequently in SDB patients (9/11, 82%) than in non-SDB subjects (2/9, 22%; exact logistic regression analysis: P=0.022, odds ratio 3.6, 95% confidence interval 1.1-15.4). Receiver operating characteristic curve analyses indicated AHI >10h -1 and presence of habitual snoring as clinically useful predictors for the occurrence of RP closure during PPV. Dynamic RP closing pressure was greater than the static RP closing pressure by approximately 4-5 cm H 2 O. Valve-like dynamic RP closure that limits expiratory flow during nasal PPV occurs more frequently in SDB patients. Copyright © 2017. Published by Elsevier Ltd.
Lack of phosphoinositide 3-kinase-gamma attenuates ventilator-induced lung injury.
Lionetti, Vincenzo; Lisi, Alberto; Patrucco, Enrico; De Giuli, Paolo; Milazzo, Maria Giovanna; Ceci, Simone; Wymann, Matthias; Lena, Annalisa; Gremigni, Vittorio; Fanelli, Vito; Hirsch, Emilio; Ranieri, V Marco
2006-01-01
G protein-coupled receptors may up-regulate the inflammatory response elicited by ventilator-induced lung injury but also regulate cell survival via protein kinase B (Akt) and extracellular signal regulated kinases 1/2 (ERK1/2). The G protein-sensitive phosphoinositide-3-kinase gamma (PI3Kgamma) regulates several cellular functions including inflammation and cell survival. We explored the role of PI3Kgamma on ventilator-induced lung injury. Prospective, randomized, experimental study. University animal research laboratory. Wild-type (PI3Kgamma), knock-out (PI3Kgamma ), and kinase-dead (PI3Kgamma) mice. Three ventilatory strategies (no stretch, low stretch, high stretch) were studied in an isolated, nonperfused model of acute lung injury (lung lavage) in PI3Kgamma, PI3Kgamma, and PI3Kgamma mice. Reduction in lung compliance, hyaline membrane formation, and epithelial detachment with high stretch were more pronounced in PI3Kgamma than in PI3Kgamma and PI3Kgamma (p < .01). Inflammatory cytokines and IkBalpha phosphorylation with high stretch did not differ among PI3Kgamma, PI3Kgamma, and PI3Kgamma. Apoptotic index (terminal deoxynucleotidyl transferase-mediated biotin-dUTP nick-end labeling) and caspase-3 (immunohistochemistry) with high stretch were larger (p < .01) in PI3Kgamma and PI3Kgamma than in PI3Kgamma. Electron microscopy showed that high stretch caused apoptotic changes in alveolar cells of PI3Kgamma mice whereas PI3Kgamma mice showed necrosis. Phosphorylation of Akt and ERK1/2 with high stretch was more pronounced in PI3Kgamma than in PI3Kgamma and PI3Kgamma (p < .01). Silencing PI3Kgamma seems to attenuate functional and morphological consequences of ventilator-induced lung injury independently of inhibitory effects on cytokines release but through the enhancement of pulmonary apoptosis.
Gucyetmez, B; Atalan, H K; Aslan, S; Yazar, S; Polat, K Y
2016-10-01
Magnesium is an N-methyl-d-aspartate receptor blocker and is known to have analgesic effect. Hypomagnesemia can often be seen in liver transplantation and may be associated with higher morbidity and mortality. The objective of this study was to investigate the effects of intraoperative magnesium sulfate administration on postoperative tramadol requirement in liver transplant patients. Liver transplant patients >18 years of age were screened prospectively from October 2014 to April 2015. Of these, 35 randomly selected patients with normal blood magnesium level (≥1.8 mmol/L) were included in a control group and another 35 randomly selected patients with low magnesium level (<1.8 mmol/L) were given 50 mg/kg intravenous magnesium sulfate replacement in the last 30 minutes of the operation. All patients received standard anesthesia induction and maintenance. Patient's age, sex, body mass index, Model for End-Stage Liver Disease and Acute Physiology and Chronic Health Evaluation II scores, 24-hour tramadol requirement, mechanical ventilation duration, and time of 1st tramadol need were recorded. In the magnesium group, mean 24-hour total tramadol requirement (3.7 mg/kg/d) and duration of mechanical ventilation (6.3 h) were significantly lower and time of 1st tramadol need (17.5 h) was significantly higher than in the control group (P < .001 for each). In the multivariate analysis, duration of mechanical ventilation was decreased by the usage of magnesium sulfate (P < .001). Intraoperative use of magnesium sulfate in liver transplantation reduces the need for postoperative tramadol and duration of mechanical ventilation and therefore it is a candidate to be adjuvant agent. Copyright © 2016 Elsevier Inc. All rights reserved.
National Grid Deep Energy Retrofit Pilot Program—Clark Residence
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2010-03-30
In this case study, Building Science Corporation partnered with local utility company, National Grid, Massachusetts homes. This project involved the renovation of a 18th century Cape-style building and achieved a super-insulated enclosure (R-35 walls, R-50+ roof, R-20+ foundation), extensive water management improvements, high-efficiency water heater, and state-of-the-art ventilation.
Green Pays Its Way--Performance-Based Fees.
ERIC Educational Resources Information Center
Burns, Cameron M.; Eubank, Huston
2002-01-01
Reports that giving building and design professionals a financial incentive to create high-efficiency schools has proven to be a winning strategy for both the firms that design and build schools and the students who learn in them. Discusses a group of educators who had heard about the effects of natural lighting and ventilation on student and…
Zhang, J H; Luo, Q; Zhang, H J; Chen, R C
2017-06-12
Objective: To investigate the effect of noninvasive proportional assist ventilation (PAV) on respiratory work in chronic obstructive pulmonary disease(COPD) patients, in comparison to noninvasive pressure support ventilation(PSV). Methods: Ten severe COPD patients with hypercapnia during acute exacerbation were examined. The baseline inspiratory pressure of PSV (PS) and the assistance level of PAV(PA) were titrated by patients' tolerance. In addition to the baseline PS and PA, an additional decrease by 25% (PS-=75% PS, PA-=75% PA) or increase by 25% (PS+ =125% PS, PA+ =125% PA) of the assist level were applied to the patients. After the assessment of unassisted spontaneous breathing (SB), the patient was placed on the 6 levels of noninvasive-PSV and noninvasive-PAV in random sequence. Each level lasted at least 20 minutes. Respiratory rate (RR), tidal volume (Vt), and respiratory work(Wex, Wip and Wv) were measured. Asynchrony index (AI) was calculated. Results: During ventilation, Vt was significantly higher with each assist level than with SB. The Vt was significant increased with PS+ than with PA+ . An increase in expiratory work(Wex) and decrease in inspiratory work(Wip) were observed respectively, with the increasing assist level. The inspiratory muscles assessed by Wip were more unloaded at PS compared with PA [PS: (1.59±1.27) J/min vs PA: (4.99±3.48) J/min P <0.01]. However, the Wex was significantly higher with PS+ than with PA+ [PS+ : (1.17±0.54) J/min vs PA+ : (0.49±0.56)J/min, P <0.01]. The AI was increased with the increasing assist level of PSV [PS-: (0.46±0.57)%, PS: (1.36±1.24)% PS+ : (5.26±4.77)]. No asynchrony events were observed at PA- and PA. "Runaway" (expiratory asynchrony) was observed during PA+ [AI: (2.62±2.72)%]. Conclusions: Noninvasive-PAV can increase the Vt and decrease the Wip of the COPD patients with hypercapnia and avoid the over-assistance. The "Runaway" will occur at assist level higher than that set by tolerance. Physiological data can monitor the patient's responses and the ventilator-patient interaction, which may provide objective criteria for ventilator setting.
Effect of short-term acclimatization to high altitude on sleep and nocturnal breathing.
Nussbaumer-Ochsner, Yvonne; Ursprung, Justyna; Siebenmann, Christoph; Maggiorini, Marco; Bloch, Konrad E
2012-03-01
Objective physiologic data on sleep and nocturnal breathing at initial exposure and during acclimatization to high altitude are scant. We tested the hypothesis that acute exposure to high altitude induces quantitative and qualitative changes in sleep and that these changes are partially reversed with acclimatization. Prospective observation. One night in a sleep laboratory at 490 meters, the first and the third night in a mountain hut at 4559 meters. Sixteen healthy mountaineers. Altitude exposure. Polysomnography, questionnaire evaluation of sleep and acute mountain sickness. Compared to 490 m, median nocturnal oxygen saturation decreased during the 1st night at 4559 m from 96% to 67%, minute ventilation increased from 4.4 to 6.3 L/min, and the apnea-hypopnea index increased from 0.1 to 60.9/h; correspondingly, sleep efficiency decreased from 93% to 69%, and slow wave sleep from 18% to 6% (P < 0.05, all instances). During the 3rd night at 4559 m, oxygen saturation was 71%, slow wave sleep 11% (P < 0.05 vs. 1st night, both instances) and the apnea/hypopnea index was 86.5/h (P = NS vs. 1st night). Symptoms of AMS and of disturbed sleep were significantly reduced in the morning after the 3rd vs. the 1st night at 4559 m. In healthy mountaineers ascending rapidly to high altitude, sleep quality is initially impaired but improves with acclimatization in association with improved oxygen saturation, while periodic breathing persists. Therefore, high altitude sleep disturbances seem to be related predominantly to hypoxemia rather than to periodic breathing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilcox, Brian; May, Doug; Howlett, Don
2013-07-01
Whiteshell Laboratories (WL) is a nuclear research establishment owned by the Canadian government and operated by Atomic Energy of Canada Limited (AECL) since the early 1960's. WL is currently under a decommissioning license and the mandate is to remediate the nuclear legacy liabilities in a safe and cost effective manner. The WL Project is the first major nuclear decommissioning project in Canada. A major initiative underway is to decommission and demolish the main R and D Laboratory complex. The Building 300 R and D complex was constructed to accommodate laboratories and offices which were mainly used for research and developmentmore » associated with organic-cooled reactors, nuclear fuel waste management, reactor safety, advanced fuel cycles and other applications of nuclear energy. Building 300 is a three storey structure of approximately 16,000 m{sup 2}. In order to proceed with building demolition, the contaminated systems inside the building have to be characterized, removed, and the waste managed. There is a significant focus on volume reduction of radioactive waste for the WL project. The active ventilation system is one of the significant contaminated systems in Building 300 that requires decommissioning and removal. The active ventilation system was designed to manage hazardous fumes and radioactivity from ventilation devices (e.g., fume hoods, snorkels and glove boxes) and to prevent the escape of airborne hazardous material outside of the laboratory boundary in the event of an upset condition. The system includes over 200 ventilation devices and 32 active exhaust fan units and high efficiency particulate air (HEPA) filters. The strategy to remove the ventilation system was to work from the laboratory end back to the fan/filter system. Each ventilation duct was radiologically characterized. Fogging was used to minimize loose contamination. Sections of the duct were removed by various cutting methods and bagged for temporary storage prior to disposition. Maintenance of building heating, ventilation and air conditioning (HVAC) balancing was critical to ensure proper airflow and worker safety. Approximately 103 m{sup 3} of equipment and materials were recovered or generated by the project. Low level waste accounted for approximately 37.4 m{sup 3}. Where possible, ducting was free released for metal recycling. Contaminated ducts were compacted into B-1000 containers and stored in a Shielded Modular Above-Ground Storage Facility (SMAGS) on the WL site awaiting final disposition. The project is divided into three significant phases, with Phases 1 and 2 completed. Lessons learned during the execution of Phases 1 and 2 have been incorporated into the current ventilation removal. (authors)« less
Scintigraphy for Pulmonary Capillary Protein Leak
1982-09-01
called this rising ratio the "slope of injury" or "slope index" ýS1). In previous canine oloic acid studies, we have found that the SI was proportional...cannulation. 2. Canine Studios Dogs weighing approximately 20 kg, were anest•:etized with 30 mg/kg sodium pentobarbital, intubated, and ventilated at...SI was seen, analogous to that seen with 0.05 ml/kg ujeic acid and the SI was repro- ducible two hours following lCI. e. Canine Endotoxin Studies: Two
Motor neurone disease presenting as polycythaemia.
Santana-Vaz, Natasha; Bwika, Jumaa; Morley, Kirstie; Mukherjee, Rahul
2014-04-28
Motor neurone disease (MND) is a chronic, progressive and currently incurable neurodegenerative disorder. This case report discusses an instance of MND presenting initially as polycythaemia, caused via insidious respiratory failure through ventilatory insufficiency. This case aims to improve clinicians' awareness of this atypical presentation and highlights the need for a high index of suspicion of respiratory failure in any patient with polycythaemia. Finally it demonstrates an improvement in quality of life associated with the use of non-invasive ventilation (NIV) in a patient with MND.
Mechanical ventilation for amyotrophic lateral sclerosis/motor neuron disease.
Radunovic, Aleksandar; Annane, Djillali; Rafiq, Muhammad K; Mustfa, Naveed
2013-03-28
Amyotrophic lateral sclerosis, also known as motor neuron disease, is a fatal neurodegenerative disease. Neuromuscular respiratory failure is the commonest cause of death, usually within two to five years of the disease onset. Supporting respiratory function with mechanical ventilation may improve survival and quality of life. This is the first update of a review first published in 2009. The primary objective of the review is to examine the efficacy of mechanical ventilation (tracheostomy and non-invasive ventilation) in improving survival in ALS. The secondary objectives are to examine the effect of mechanical ventilation on functional measures of disease progression and quality of life in people with ALS; and assess adverse events related to the intervention. We searched The Cochrane Neuromuscular Disease Group Specialized Register (1 May 2012), CENTRAL (2012, Issue 4), MEDLINE (January 1966 to April 2012), EMBASE (January 1980 to April 2012), CINAHL Plus (January 1937 to April 2012), and AMED (January 1985 to April 2012). We also searched for ongoing studies on ClinicalTrials.gov. Randomised and quasi-randomised controlled trials involving non-invasive or tracheostomy assisted ventilation in participants with a clinical diagnosis of amyotrophic lateral sclerosis, independent of the reported outcomes. We planned to include comparisons with no intervention or the best standard care. For the original review, four authors independently selected studies for assessment and two authors reviewed searches for this update. All authors extracted data independently from the full text of selected studies and assessed the risk of bias in studies that met the inclusion criteria. We attempted to obtain missing data where possible. We planned to collect adverse event data from included studies. For the original Cochrane review, the review authors identified and included two randomised controlled trials involving 54 participants with ALS receiving non-invasive ventilation. There were no new randomised or quasi-randomised controlled trials at this first update.Incomplete data were published for one study and we contacted the trial authors who were not able to provide the missing data. Therefore, the results of the review were based on a single study of 41 participants that compared non-invasive ventilation with standard care. It was a well conducted study with low risk of bias.The study showed that the overall median survival was significantly different between the group treated with non-invasive ventilation and the standard care group. The median survival in the non-invasive ventilation group was 48 days longer (219 days compared to 171 days for the standard care group (estimated 95% CI 12 to 91 days, P = 0.0062)). This survival benefit was accompanied by an enhanced quality of life. On subgroup analysis, the survival and quality of life benefit was much more in the subgroup with normal to moderately impaired bulbar function (20 participants); median survival was 205 days longer (216 days in NIV group versus 11 days in the standard care group, P = 0.0059). Non-invasive ventilation did not prolong survival in participants with poor bulbar function (21 participants), although it showed significant improvement in the mean symptoms domain of the Sleep Apnoea Quality of Life Index but not in the Short Form-36 Health Survey Mental Component Summary score. Neither trial reported clinical data on intervention related adverse effects. Evidence from a single randomised trial of non-invasive ventilation in 41 participants suggests that it significantly prolongs survival and improves or maintains quality of life in people with ALS. Survival and some measures of quality of life were significantly improved in the subgroup of people with better bulbar function, but not in those with severe bulbar impairment. Future studies should examine the health economics of NIV and factors influencing access to NIV. We need to understand the factors, personal and socioeconomic, that determine access to NIV.
Closed-loop control of propofol anaesthesia.
Kenny, G N; Mantzaridis, H
1999-08-01
We describe the use of a closed-loop system to control depth of propofol anaesthesia automatically. We used the auditory evoked potential index (AEPindex) as the input signal of this system to validate it as a true measure of depth of anaesthesia. Auditory evoked potentials were acquired and processed in real time to provide the AEPindex. The AEPindex was used in a proportional integral (PI) controller to determine the target blood concentration of propofol required to induce and maintain general anaesthesia automatically. We studied 100 spontaneously breathing patients. The mean AEPindex before induction of anaesthesia was 73.5 (SD 17.6), during surgical anaesthesia 37.8 (4.5) and at recovery of consciousness 89.7 (17.9). Twenty-two patients required assisted ventilation before incision. After incision, ventilation was assisted in four of these 22 patients for more than 5 min. There was no incidence of intraoperative awareness and all patients were prepared to have the same anaesthetic in future. Movement interfering with surgery was minimal. Cardiovascular stability and overall control of anaesthesia were satisfactory.
Absorption atelectasis: incidence and clinical implications.
O'Brien, Jennifer
2013-06-01
General anesthesia is known to cause pulmonary atelectasis; in turn, atelectasis increases shunt, decreases compliance, and may lead to perioperative hypoxemia. One mechanism for the formation of atelectasis intraoperatively is ventilation with 100% oxygen. The goal of this review is to determine if research suggests that intraoperative ventilation with 100% oxygen leads to clinically significant pulmonary side effects. An initial literature search included electronic databases (Cumulative Index to Nursing & Allied Health Literature [CINAHL], PubMed, MEDLINE, Embase, and The GeneraCochrane Library) using the following search terms: oxygen (administration and dosage), atelectasis, pulmonary complications, and anesthesia. Results were limited to research studies, human subjects, and English-language publications between 1965 and 2011. From this body of research, it appears that absorption atelectasis does occur in healthy anesthetized adults breathing 100% oxygen. Data reviewed suggest that absorption atelectasis does not have significant clinical implications in healthy adults. However, further research is warranted in populations at increased risk of postoperative hypoxemia, including obese or elderly patients and those with preexisting cardiopulmonary disease.