Ventilatory thresholds determined from HRV: comparison of 2 methods in obese adolescents.
Quinart, S; Mourot, L; Nègre, V; Simon-Rigaud, M-L; Nicolet-Guénat, M; Bertrand, A-M; Meneveau, N; Mougin, F
2014-03-01
The development of personalised training programmes is crucial in the management of obesity. We evaluated the ability of 2 heart rate variability analyses to determine ventilatory thresholds (VT) in obese adolescents. 20 adolescents (mean age 14.3±1.6 years and body mass index z-score 4.2±0.1) performed an incremental test to exhaustion before and after a 9-month multidisciplinary management programme. The first (VT1) and second (VT2) ventilatory thresholds were identified by the reference method (gas exchanges). We recorded RR intervals to estimate VT1 and VT2 from heart rate variability using time-domain analysis and time-varying spectral-domain analysis. The coefficient correlations between thresholds were higher with spectral-domain analysis compared to time-domain analysis: Heart rate at VT1: r=0.91 vs. =0.66 and VT2: r=0.91 vs. =0.66; power at VT1: r=0.91 vs. =0.74 and VT2: r=0.93 vs. =0.78; spectral-domain vs. time-domain analysis respectively). No systematic bias in heart rate at VT1 and VT2 with standard deviations <6 bpm were found, confirming that spectral-domain analysis could replace the reference method for the detection of ventilatory thresholds. Furthermore, this technique is sensitive to rehabilitation and re-training, which underlines its utility in clinical practice. This inexpensive and non-invasive tool is promising for prescribing physical activity programs in obese adolescents. © Georg Thieme Verlag KG Stuttgart · New York.
Gaskill, S E; Walker, A J; Serfass, R A; Bouchard, C; Gagnon, J; Rao, D C; Skinner, J S; Wilmore, J H; Leon, A S
2001-11-01
The purpose of this study was to evaluate the effect of exercise training intensity relative to the ventilatory threshold (VT) on changes in work (watts) and VO2 at the ventilatory threshold and at maximal exercise in previously sedentary participants in the HERITAGE Family Study. We hypothesized that those who exercised below their VT would improve less in VO2 at the ventilatory threshold (VO2vt) and VO2max than those who trained at an intensity greater than their VT. Supervised cycle ergometer training was performed at the 4 participating clinical centers, 3 times a week for 20 weeks. Exercise training progressed from the HR corresponding to 55% VO2max for 30 minutes to the HR associated with 75% VO2max for 50 minutes for the final 6 weeks. VT was determined at baseline and after exercise training using standardized methods. 432 sedentary white and black men (n = 224) and women (n = 208), aged 17 to 65 years, were retrospectively divided into groups based on whether exercise training was initiated below, at, or above VT. 1) Training intensity (relative to VT) accounting for about 26% of the improvement in VO2vt (R2 = 0.26, p < 0.0001). 2) The absolute intensity of training in watts (W) accounted for approximately 56% of the training effect at VT (R2 = 0.56, p < 0.0001) with post-training watts at VT (VT(watts)) being not significantly different than W during training (p > 0.70). 3) Training intensity (relative to VT) had no effect on DeltaVO2max. These data clearly show that as a result of aerobic training both the VO2 and W associated with VT respond and become similar to the absolute intensity of sustained (3 x /week for 50 min) aerobic exercise training. Higher intensities of exercise, relative to VT, result in larger gains in VO2vt but not in VO2max.
Anaerobic threshold determination through ventilatory and electromyographics parameters.
Gassi, E R; Bankoff, A D P
2010-01-01
The aim of present study was to compare the alterations in electromyography signs with Ventilatory Threshold (VT). Had been part of the study eight men, amateur cyclists and triathletes (25.25 +/- 6.96 years), that they had exercised themselves in a mechanical cicloergometer, a cadence of 80 RPM and with the increased intensity being in 25 W/min until the exhaustion. The VT was determined by a non-linear increase in VE/VO2 without any increase in VE/VCO2 and compared with the intensity corresponding to break point of amplitude EMG sign during the incremental exercise. The EMG--Fatigue Threshold (FT) and Ventilatory Threshold (VT) parameters used were the power, the time, absolute and relative VO2, ventilation (VE), the heart hate (HH) and the subjective perception of the effort. The results had not shown to difference in none of the variable selected for the corresponding intensity to VT and FT--EMG of the muscles lateralis vastus and femoris rectus. The parameters used in the comparison between the electromyographic indicators and ventilatory were the load, the time, absolute VO2 and relative to corporal mass, to ventilation (VE), the heart frequency (HH) and the Subjective Perception of the Effort (SPE).
Comparison of Ventilatory Measures and 20 km Time Trial Performance.
Peveler, Willard W; Shew, Brandy; Johnson, Samantha; Sanders, Gabe; Kollock, Roger
2017-01-01
Performance threshold measures are used to predict cycling performance. Previous research has focused on long time trials (≥ 40 km) using power at ventilatory threshold and respiratory threshold to estimate time trial performance. As intensity greatly differs during shorter time trails applying findings from longer time trials may not be appropriate. The use of heart rate measures to determine 20 km time trial performance has yet to be examined. The purpose of this study was to determine the effectiveness of heart rate measures at ventilatory threshold (VE/VO 2 Plotted and VT determined by software) and respiratory threshold (RER of 0.95, 1.00, and 1.05) to predict 20 km time trial performance. Eighteen cyclists completed a VO 2max protocol and two 20 km time trials. Average heart rates from 20 km time trials were compared with heart rates from performance threshold measures (VT plotted, VT software, and an RER at 0.95, 1.00, and 1.05) using repeated measures ANOVA. Significance was set a priori at P ≤ 0.05. The only measure not found to be significantly different in relation to time trial performance was HR at an RER of 1.00 (166.61±12.70 bpm vs. 165.89 ± 9.56 bpm, p = .671). VT plotting and VT determined by software were found to underestimate time trial performance by 3% and 8% respectively. From these findings it is recommended to use heart rate at a RER of 1.00 in order to determine 20 km time trial intensity.
Kendall, Kristina L; Smith, Abbie E; Graef, Jennifer L; Walter, Ashley A; Moon, Jordan R; Lockwood, Christopher M; Beck, Travis W; Cramer, Joel T; Stout, Jeffrey R
2010-01-01
The submaximal electromyographic fatigue threshold test (EMG(FT)) has been shown to be highly correlated to ventilatory threshold (VT) as determined from maximal graded exercise tests (GXTs). Recently, a prediction equation was developed using the EMG(FT) value to predict VT. The aim of this study, therefore, was to determine if this new equation could accurately track changes in VT after high-intensity interval training (HIIT). Eighteen recreationally trained men (mean +/- SD; age 22.4 +/- 3.2 years) performed a GXT to determine maximal oxygen consumption rate (V(O2)peak) and VT using breath-by-breath spirometry. Participants also completed a discontinuous incremental cycle ergometer test to determine their EMGFT value. A total of four 2-minute work bouts were completed to obtain 15-second averages of the electromyographic amplitude. The resulting slopes from each successive work bout were used to calculate EMG(FT). The EMG(FT) value from each participant was used to estimate VT from the recently developed equation. All participants trained 3 days a week for 6 weeks. Training consisted of 5 sets of 2-minute work bouts with 1 minute of rest in between. Repeated-measures analysis of variance indicated no significant difference between actual and predicted VT values after 3 weeks of training. However, there was a significant difference between the actual and predicted VT values after 6 weeks of training. These findings suggest that the EMG(FT) may be useful when tracking changes in VT after 3 weeks of HIIT in recreationally trained individuals. However, the use of EMG(FT) to predict VT does not seem to be valid for tracking changes after 6 weeks of HIIT. At this time, it is not recommended that EMG(FT) be used to predict and track changes in VT.
Evans, B W; Potteiger, J A
1995-06-01
This study compared ventilatory and metabolic responses during exercise using three breathing assemblies: mouthpiece/noseclip (BV); mouth/face mask (MM); and facemask (FM). Ten male runners completed three maximal treadmill tests with breathing assembly randomly assigned. Metabolic and ventilatory data were recorded every 15s, and heart rate (HR) and rating of perceived exertion (RPE) each min. No significant differences were found for treadmill run time, HRmax, respiratory exchange ratio (RER), and RPE, indicating similar efforts on all trials. No significant differences were found at maximal exercise for VO2 minute ventilation (VE), tidal volume (VT), and breathing frequency (f). At ventilatory threshold (TVENT), VO2, VE, and f were not significantly different. However, peak flow (PF) was significantly higher for BV than FM, and VT was significantly higher for BV than MM and FM. Results indicate alterations in ventilatory mechanics occur at TVENT, but type of breathing assembly does not significantly affect maximal values.
Shiraishi, Yasuyuki; Katsumata, Yoshinori; Sadahiro, Taketaro; Azuma, Koichiro; Akita, Keitaro; Isobe, Sarasa; Yashima, Fumiaki; Miyamoto, Kazutaka; Nishiyama, Takahiko; Tamura, Yuichi; Kimura, Takehiro; Nishiyama, Nobuhiro; Aizawa, Yoshiyasu; Fukuda, Keiichi; Takatsuki, Seiji
2018-01-07
It has never been possible to immediately evaluate heart rate variability (HRV) during exercise. We aimed to visualize the real-time changes in the power spectrum of HRV during exercise and to investigate its relationship to the ventilatory threshold (VT). Thirty healthy subjects (29.1±5.7 years of age) and 35 consecutive patients (59.0±13.2 years of age) with myocardial infarctions underwent cardiopulmonary exercise tests with an RAMP protocol ergometer. The HRV was continuously assessed with power spectral analyses using the maximum entropy method and projected on a screen without delay. During exercise, a significant decrease in the high frequency (HF) was followed by a drastic shift in the power spectrum of the HRV with a periodic augmentation in the low frequency/HF (L/H) and steady low HF. When the HRV threshold (HRVT) was defined as conversion from a predominant high frequency (HF) to a predominant low frequency/HF (L/H), the VO 2 at the HRVT (HRVT-VO 2 ) was substantially correlated with the VO 2 at the lactate threshold and VT) in the healthy subjects ( r =0.853 and 0.921, respectively). The mean difference between each threshold (0.65 mL/kg per minute for lactate threshold and HRVT, 0.53 mL/kg per minute for VT and HRVT) was nonsignificant ( P >0.05). Furthermore, the HRVT-VO 2 was also correlated with the VT-VO 2 in these myocardial infarction patients ( r =0.867), and the mean difference was -0.72 mL/kg per minute and was nonsignificant ( P >0.05). A HRV analysis with our method enabled real-time visualization of the changes in the power spectrum during exercise. This can provide additional information for detecting the VT. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Greer, Beau Kjerulf; Katalinas, Matthew E; Shaholli, Danielle M; Gallo, Paul M
2016-01-01
The purpose of the present study was to determine the effect of 30 days of β-alanine supplementation on peak aerobic power and ventilatory threshold (VT) in aerobically fit males. Fourteen males (28.8 ± 9.8 yrs) were assigned to either a β-alanine (SUPP) or placebo (PLAC) group; groups were matched for VT as it was the primary outcome measure. β-alanine supplementation consisted of 3 g/day for 7 days, and 6 g/day for the remaining 23 days. Before and after the supplementation period, subjects performed a continuous, graded cycle ergometry test to determine VO2 peak and VT. Metabolic data were analyzed using a 2 × 2 ANOVA with repeated measures. Thirty days of β-alanine supplementation (SUPP) did not increase VO2 peak (4.05 ± 0.6 vs. 4.14 ± 0.6 L/min) as compared to the placebo (PLAC) group (3.88 ± 0.2 vs. 3.97 ± 0.2 L/min) (p > .05). VT did not significantly improve in either the SUPP (3.21 ± 0.5 vs. 3.33 ± 0.5 L/min) or PLAC (3.19 ± 0.1 vs. 3.20 ± 0.1 L/min) group (p > .05). In conclusion, 30 days of β-alanine supplementation had no effect on VO2 peak or VT in aerobically trained athletes.
Zhang, Jian-Guo; Ohta, Toshiki; Ishikawa-Takata, Kazuko; Tabata, Izumi; Miyashita, Mitsumasa
2003-09-01
The relationships among walk steps, exercise habits and peak oxygen consumption (VO2peak), ventilatory threshold (VT) and leg extension power (LEP) were examined in 709 apparently healthy Japanese subjects (male 372, female 337) aged 30-69 years. Walk steps were evaluated using a pedometer. VO2peak and VT were assessed by a cycle ergometer test, while LEP was measured with an isokinetic leg extension system (Combi, Anaero Press 3500, Japan). Subjects who participated in exercise three times or more a week demonstrated significantly greater VO2peak and VT when compared with subjects without exercise habits. When a separate analysis was conducted on subjects who exercised fewer than three times per week, we found that the subgroup with the highest number of walk steps showed significantly greater VT in all male subjects and female subjects aged 30-49 years, but a significantly greater VO2peak only in females aged 30-49 years, when compared to the subgroup with the fewest walk steps. These results suggest that although some people exercise less than three times a week, if they are quite active in daily life, such activities might also confer benefits upon their fitness.
Sunderland, Kyle L; Greer, Felicia; Morales, Jacobo
2011-03-01
The ergogenic effect of L-arginine on an endurance-trained population is not well studied. The few studies that have investigated L-arginine on this population have not been conducted in a laboratory setting or measured aerobic variables. The purpose of the current study is to determine if 28 days of L-arginine supplementation in trained male cyclists affects VO2max and ventilatory threshold (VT). Eighteen (18) endurance-trained male cyclists (mean ± SD, age: 36.3 ± 7.9 years; height: 182.4 ± 4.6 cm; and body mass: 79.5 ± 4.7 kg) performed a graded exercise test (GXT; 50 W + 25 W·min) before and after 28 days of supplementation with L-arginine (ARG; 2 × 6 g·d) or placebo (PLA; cornstarch). The GXT was conducted on the subject's own bicycle using the RacerMate CompuTrainer (Seattle, WA, USA). VO2 was continuously recorded using the ParvoMedics TrueOne 2400 metabolic cart (Salt Lake City, UT, USA) and VT was established by plotting the ventilatory equivalent for O2 (VE/VO2) and the ventilatory equivalent for CO2 (VE/VCO2) and identifying the point at which VE/VO2 increases with no substantial changes in VE/VCO2. L-arginine supplementation had no effect from initial VO2max (PL, 58.7 ± 7.1 ml·kg·min; ARG, 63.5 ± 7.3 ml·kg·min) to postsupplement VO2max (PL, 58.9 ± 6.0 ml·kg·min; ARG, 63.2 ± 7.2 ml·kg·min). Also, no effect was seen from initial VT (PL, 75.7 ± 4.6% VO2max; ARG, 76.0 ± 5.3% VO2max) to postsupplement VT (PL, 74.3 ± 8.1% VO2max; ARG, 74.2 ± 6.4% VO2max). These results indicate that L-arginine does not impact VO2max or VT in trained male cyclists.
The Effects of a Duathlon Simulation on Ventilatory Threshold and Running Economy
Berry, Nathaniel T.; Wideman, Laurie; Shields, Edgar W.; Battaglini, Claudio L.
2016-01-01
Multisport events continue to grow in popularity among recreational, amateur, and professional athletes around the world. This study aimed to determine the compounding effects of the initial run and cycling legs of an International Triathlon Union (ITU) Duathlon simulation on maximal oxygen uptake (VO2max), ventilatory threshold (VT) and running economy (RE) within a thermoneutral, laboratory controlled setting. Seven highly trained multisport athletes completed three trials; Trial-1 consisted of a speed only VO2max treadmill protocol (SOVO2max) to determine VO2max, VT, and RE during a single-bout run; Trial-2 consisted of a 10 km run at 98% of VT followed by an incremental VO2max test on the cycle ergometer; Trial-3 consisted of a 10 km run and 30 km cycling bout at 98% of VT followed by a speed only treadmill test to determine the compounding effects of the initial legs of a duathlon on VO2max, VT, and RE. A repeated measures ANOVA was performed to determine differences between variables across trials. No difference in VO2max, VT (%VO2max), maximal HR, or maximal RPE was observed across trials. Oxygen consumption at VT was significantly lower during Trial-3 compared to Trial-1 (p = 0.01). This decrease was coupled with a significant reduction in running speed at VT (p = 0.015). A significant interaction between trial and running speed indicate that RE was significantly altered during Trial-3 compared to Trial-1 (p < 0.001). The first two legs of a laboratory based duathlon simulation negatively impact VT and RE. Our findings may provide a useful method to evaluate multisport athletes since a single-bout incremental treadmill test fails to reveal important alterations in physiological thresholds. Key points Decrease in relative oxygen uptake at VT (ml·kg-1·min-1) during the final leg of a duathlon simulation, compared to a single-bout maximal run. We observed a decrease in running speed at VT during the final leg of a duathlon simulation; resulting in an increase of more than 2 minutes to complete a 5 km run. During our study, highly trained athletes were unable to complete the final 5 km run at the same intensity that they completed the initial 10 km run (in a laboratory setting). A better understanding, and determination, of training loads during multisport training may help to better periodize training programs; additional research is required. PMID:27274661
Boyne, Pierce; Reisman, Darcy; Brian, Michael; Barney, Brian; Franke, Ava; Carl, Daniel; Khoury, Jane; Dunning, Kari
2017-03-01
After stroke, aerobic deconditioning can have a profound impact on daily activities. This is usually measured by the peak oxygen consumption rate achieved during exercise testing (VO2-peak). However, VO2-peak may be distorted by motor function. The oxygen uptake efficiency slope (OUES) and VO2 at the ventilatory threshold (VO2-VT) could more specifically assess aerobic capacity after stroke, but this has not been tested. To assess the differential influence of motor function on three measures of aerobic capacity (VO2-peak, OUES, and VO2-VT) and to evaluate the inter-rater reliability of VO2-VT determination post-stroke. Among 59 persons with chronic stroke, cross-sectional correlations with motor function (comfortable gait speed [CGS] and lower extremity Fugl-Meyer [LEFM]) were compared between the different aerobic capacity measures, after adjustment for covariates, in order to isolate any distorting effect of motor function. Reliability of VO2-VT determination between three raters was assessed with intra-class correlation (ICC). CGS was moderately correlated with VO2-peak (r = 0.52, p < 0.0001) and weakly correlated with OUES (r = 0.41, p = 0.002) and VO2-VT (r = 0.37, p = 0.01). LEFM was weakly correlated with VO2-peak (r = 0.26, p = 0.055) and very weakly correlated with OUES (r = 0.19, p = 0.17) and VO2-VT (r = 0.14, p = 0.31). Compared to VO2-peak, VO2-VT was significantly less correlated with CGS (r difference = -0.16, p = 0.02). Inter-rater reliability of VO2-VT determination was high (ICC: 0.93, 95% CI: 0.89-0.96). Motor dysfunction appears to artificially lower measured aerobic capacity. VO2-VT seemed to be less distorted than VO2-peak and had good inter-rater reliability, so it may provide more specific assessment of aerobic capacity post-stroke.
The influence of weight loss on anaerobic threshold in obese women.
Zak-Golab, Agnieszka; Zahorska-Markiewicz, Barbara; Langfort, Józef; Kocelak, Piotr; Holecki, Michal; Mizia-Stec, Katarzyna; Olszanecka-Glinianowicz, Magdalena; Chudek, Jerzy
2010-01-01
Obesity is associated with decreased physical activity. The aim of the study was to assess the anaerobic threshold in obese and normal weight women and to analyse the effect of weight-reduction therapy on the determined thresholds. 42 obese women without concomitant disease (age 30.5 ± 6.9y; BMI 33.6 ± 3.7 kg·m(-2)) and 19 healthy normal weight women (age 27.6 ± 7.0y; BMI 21.2 ± 1.9 kg·m(-2)) performed cycle ergometer incremental ramp exercise test up to exhaustion. The test was repeated in 19 obese women after 12.3 ± 4.2% weight loss. The lactate threshold (LT) and the ventilatory threshold (VT) were determined. Obese women had higher lactate (expressed as oxygen consumption) and ventilator threshold than normal weight women. The lactate threshold was higher than ventilatory one both in obese and normal weight women (1.11 ± 0.21 vs 0.88 ± 0.18 L·min(-1), p < 0.001; 0.94 ± 0.15 vs 0.79 ± 0.23 L·min(- 1), p < 0.01, respectively). After weight reduction therapy neither the lactate nor the ventilatory threshold changed significantly. The results concluded that; 1. The higher lactate threshold noted in obese women may be related to the increased fat acid usage in metabolism. 2. Both in obese and normal weight women lactate threshold appears at higher oxygen consumption than ventilatory threshold. 3. The obtained weight reduction, without weight normalisation was insufficient to cause significant changes of lactate and ventilatory thresholds in obese women. Key pointsResults showed that adolescent young female gymnasts have an altered serum inflammatory markers and endothelial activation, compared to their less physically active peers.Physical activities improved immune system.Differences in these biochemical data kept significant after adjustment for body weight and height.
Boyne, Pierce; Buhr, Sarah; Rockwell, Bradley; Khoury, Jane; Carl, Daniel; Gerson, Myron; Kissela, Brett; Dunning, Kari
2015-10-01
Treadmill aerobic exercise improves gait, aerobic capacity, and cardiovascular health after stroke, but a lack of specificity in current guidelines could lead to underdosing or overdosing of aerobic intensity. The ventilatory threshold (VT) has been recommended as an optimal, specific starting point for continuous aerobic exercise. However, VT measurement is not available in clinical stroke settings. Therefore, the purpose of this study was to identify an accurate method to predict heart rate at the VT (HRVT) for use as a surrogate for VT. A cross-sectional design was employed. Using symptom-limited graded exercise test (GXT) data from 17 subjects more than 6 months poststroke, prediction methods for HRVT were derived by traditional target HR calculations (percentage of HRpeak achieved during GXT, percentage of peak HR reserve [HRRpeak], percentage of age-predicted maximal HR, and percentage of age-predicted maximal HR reserve) and by regression analysis. The validity of the prediction methods was then tested among 8 additional subjects. All prediction methods were validated by the second sample, so data were pooled to calculate refined prediction equations. HRVT was accurately predicted by 80% HRpeak (R, 0.62; standard deviation of error [SDerror], 7 bpm), 62% HRRpeak (R, 0.66; SDerror, 7 bpm), and regression models that included HRpeak (R, 0.62-0.75; SDerror, 5-6 bpm). Derived regression equations, 80% HRpeak and 62% HRRpeak, provide a specific target intensity for initial aerobic exercise prescription that should minimize underdosing and overdosing for persons with chronic stroke. The specificity of these methods may lead to more efficient and effective treatment for poststroke deconditioning.Video Abstract available for more insights from the authors (see Supplemental Digital Content 1, http://links.lww.com/JNPT/A114).
Second ventilatory threshold from heart-rate variability: valid when the upper body is involved?
Mourot, Laurent; Fabre, Nicolas; Savoldelli, Aldo; Schena, Federico
2014-07-01
To determine the most accurate method based on spectral analysis of heart-rate variability (SA-HRV) during an incremental and continuous maximal test involving the upper body, the authors tested 4 different methods to obtain the heart rate (HR) at the second ventilatory threshold (VT(2)). Sixteen ski mountaineers (mean ± SD; age 25 ± 3 y, height 177 ± 8 cm, mass 69 ± 10 kg) performed a roller-ski test on a treadmill. Respiratory variables and HR were continuously recorded, and the 4 SA-HRV methods were compared with the gas-exchange method through Bland and Altman analyses. The best method was the one based on a time-varying spectral analysis with high frequency ranging from 0.15 Hz to a cutoff point relative to the individual's respiratory sinus arrhythmia. The HR values were significantly correlated (r(2) = .903), with a mean HR difference with the respiratory method of 0.1 ± 3.0 beats/min and low limits of agreements (around -6 /+6 beats/min). The 3 other methods led to larger errors and lower agreements (up to 5 beats/min and around -23/+20 beats/min). It is possible to accurately determine VT(2) with an HR monitor during an incremental test involving the upper body if the appropriate HRV method is used.
Cardiorespiratory responses of a dance session designed for older women: A cross sectional study.
Rodrigues-Krause, Josianne; Farinha, Juliano Boufleur; Ramis, Thiago Rozales; Boeno, Francesco Pinto; Dos Santos, Gabriela Cristina; Krause, Mauricio; Reischak-Oliveira, Alvaro
2018-06-04
Dancing has been increasingly used as a type of exercise intervention to improve cardiovascular fitness of older people. However, it is unclear which may be the exercise intensity of the dance sessions. To describe cardiorespiratory responses of a dance session for older women, and to identify intensity zones in relation to peak oxygen consumption (VO 2 peak), first and second ventilatory thresholds (VT1 and VT2). Ten women (66 ± 5 yrs., BMI 27 ± 4) were examined on three occasions: Familiarization, maximum effort and dance sessions. Incremental treadmill test: 5 km/h, 2% slope each min, until maximum effort. Dance class (60 min): warm-up (20 min), across-the-floor (10 min), choreography (15 min), show (10 min) and cool-down (5 min). Ventilatory parameters were measured continuously (breath-by-breath). VO 2 (mL·kg -1 ·min -1 ): Maximum effort: VO 2 peak (23.3 ± 4.3), VT1 (17.2 ± 3.5) and VT2 (20.9 ± 3.4). Dancing: warm-up (12.8 ± 2.4, ~55%VO 2 peak), across-the-floor (14.2 ± 2.4 ~62%VO 2 peak), choreography (14.6 ± 3.2 ~63%VO 2 peak) and show (16.1 ± 3.3, ~69% VO 2 peak). Show was similar to VT1. Cardiorespiratory demands of a dance class for older women are at low aerobic intensity. Show was similar to VT1, indicating that a dance class may be modulated to improve aerobic fitness, at least at initial stages of training. Copyright © 2018 Elsevier Inc. All rights reserved.
Objectivity and validity of EMG method in estimating anaerobic threshold.
Kang, S-K; Kim, J; Kwon, M; Eom, H
2014-08-01
The purposes of this study were to verify and compare the performances of anaerobic threshold (AT) point estimates among different filtering intervals (9, 15, 20, 25, 30 s) and to investigate the interrelationships of AT point estimates obtained by ventilatory threshold (VT) and muscle fatigue thresholds using electromyographic (EMG) activity during incremental exercise on a cycle ergometer. 69 untrained male university students, yet pursuing regular exercise voluntarily participated in this study. The incremental exercise protocol was applied with a consistent stepwise increase in power output of 20 watts per minute until exhaustion. AT point was also estimated in the same manner using V-slope program with gas exchange parameters. In general, the estimated values of AT point-time computed by EMG method were more consistent across 5 filtering intervals and demonstrated higher correlations among themselves when compared with those values obtained by VT method. The results found in the present study suggest that the EMG signals could be used as an alternative or a new option in estimating AT point. Also the proposed computing procedure implemented in Matlab for the analysis of EMG signals appeared to be valid and reliable as it produced nearly identical values and high correlations with VT estimates. © Georg Thieme Verlag KG Stuttgart · New York.
Increased ventilatory variability and complexity in patients with hyperventilation disorder.
Bokov, Plamen; Fiamma, Marie-Noëlle; Chevalier-Bidaud, Brigitte; Chenivesse, Cécile; Straus, Christian; Similowski, Thomas; Delclaux, Christophe
2016-05-15
It has been hypothesized that hyperventilation disorders could be characterized by an abnormal ventilatory control leading to enhanced variability of resting ventilation. The variability of tidal volume (VT) often depicts a nonnormal distribution that can be described by the negative slope characterizing augmented breaths formed by the relationship between the probability density distribution of VT and VT on a log-log scale. The objectives of this study were to describe the variability of resting ventilation [coefficient of variation (CV) of VT and slope], the stability in respiratory control (loop, controller and plant gains characterizing ventilatory-chemoresponsiveness interactions) and the chaotic-like dynamics (embedding dimension, Kappa values characterizing complexity) of resting ventilation in patients with a well-defined dysfunctional breathing pattern characterized by air hunger and constantly decreased PaCO2 during a cardiopulmonary exercise test. Compared with 14 healthy subjects with similar anthropometrics, 23 patients with hyperventilation were characterized by increased variability of resting tidal ventilation (CV of VT median [interquartile]: 26% [19-35] vs. 36% [28-48], P = 0.020; slope: -6.63 [-7.65; -5.36] vs. -3.88 [-5.91; -2.66], P = 0.004) that was not related to increased chemical drive (loop gain: 0.051 [0.039-0.221] vs. 0.044 [0.012-0.087], P = 0.149) but that was related to an increased ventilatory complexity (Kappa values, P < 0.05). Plant gain was decreased in patients and correlated with complexity (with Kappa 5 - degree 5: Rho = -0.48, P = 0.006). In conclusion, well-defined patients suffering from hyperventilation disorder are characterized by increased variability of their resting ventilation due to increased ventilatory complexity with stable ventilatory-chemoresponsiveness interactions. Copyright © 2016 the American Physiological Society.
Tempest, Gavin; Parfitt, Gaynor
2013-10-01
Imagery, as a cognitive strategy, can improve affective responses during moderate-intensity exercise. The effects of imagery at higher intensities of exercise have not been examined. Further, the effect of imagery use and activity in the frontal cortex during exercise is unknown. Using a crossover design (imagery and control), activity of the frontal cortex (reflected by changes in cerebral hemodynamics using near-infrared spectroscopy) and affective responses were measured during exercise at intensities 5% above the ventilatory threshold (VT) and the respiratory compensation point (RCP). Results indicated that imagery use influenced activity of the frontal cortex and was associated with a more positive affective response at intensities above VT, but not RCP to exhaustion (p < .05). These findings provide direct neurophysiological evidence of imagery use and activity in the frontal cortex during exercise at intensities above VT that positively impact affective responses.
Astorino, Todd A; deRevere, Jamie; Anderson, Theodore; Kellogg, Erin; Holstrom, Patrick; Ring, Sebastian; Ghaseb, Nicholas
2018-06-19
Completion of high-intensity interval training (HIIT) leads to significant increases in maximal oxygen uptake (VO 2max ) and oxidative capacity. However, individual responses to HIIT have been identified as approximately 20-40% of individuals show no change in VO 2max , which may be due to the relatively homogeneous approach to implementing HIIT. This study tested the effects of HIIT prescribed using ventilatory threshold (VT) on changes in VO 2max and cycling performance. Fourteen active men and women (age and VO 2max = 27 ± 8 year and 38 ± 4 mL/kg/min) underwent nine sessions of HIIT, and 14 additional men and women (age and VO 2max = 22 ± 3 year and 40 ± 5 mL/kg/min) served as controls. Training was performed on a cycle ergometer at a work rate equal to 130%VT and consisted of eight to ten 1 min bouts interspersed with 75 s of recovery. At baseline and post-testing, they completed progressive cycling to exhaustion to determine VO 2max , and on a separate day, a 5 mile cycling time trial. Compared to the control group, HIIT led to significant increases in VO 2max (6%, p = 0.007), cycling performance (2.5%, p = 0.003), and absolute VT (9 W, p = 0.005). However, only 57% of participants revealed meaningful increases in VO 2max and cycling performance in response to training, and two showed no change in either outcome. A greater volume of HIIT may be needed to maximize the training response for all individuals.
Ventilatory effects of gap junction blockade in the RTN in awake rats.
Hewitt, Amy; Barrie, Rachel; Graham, Michael; Bogus, Kara; Leiter, J C; Erlichman, Joseph S
2004-12-01
We tested the hypothesis that carbenoxolone, a pharmacological inhibitor of gap junctions, would reduce the ventilatory response to CO(2) when focally perfused within the retrotrapezoid nucleus (RTN). We tested this hypothesis by measuring minute ventilation (V(E)), tidal volume (V(T)), and respiratory frequency (F(R)) responses to increasing concentrations of inspired CO(2) (Fi(CO(2)) = 0-8%) in rats during wakefulness. We confirmed that the RTN was chemosensitive by perfusing the RTN unilaterally with either acetazolamide (AZ; 10 microM) or hypercapnic artificial cerebrospinal fluid equilibrated with 50% CO(2) (pH approximately 6.5). Focal perfusion of AZ or hypercapnic aCSF increased V(E), V(T), and F(R) during exposure to room air. Carbenoxolone (300 microM) focally perfused into the RTN decreased V(E) and V(T) in animals <11 wk of age, but V(E) and V(T) were increased in animals >12 wk of age. Glyzyrrhizic acid, a congener of carbenoxolone, did not change V(E), V(T), or F(R) when focally perfused into the RTN. Carbenoxolone binds to the mineralocorticoid receptor, but spironolactone (10 microM) did not block the disinhibition of V(E) or V(T) in older animals when combined with carbenoxolone. Thus the RTN is a CO(2) chemosensory site in all ages tested, but the function of gap junctions in the chemosensory process varies substantially among animals of different ages: gap junctions amplify the ventilatory response to CO(2) in younger animals, but appear to inhibit the ventilatory response to CO(2) in older animals.
Tennis Play Intensity Distribution and Relation with Aerobic Fitness in Competitive Players
Baiget, Ernest; Fernández-Fernández, Jaime; Iglesias, Xavier; Rodríguez, Ferran A.
2015-01-01
The aims of this study were (i) to describe the relative intensity of simulated tennis play based on the cumulative time spent in three metabolic intensity zones, and (ii) to determine the relationships between this play intensity distribution and the aerobic fitness of a group of competitive players. 20 male players of advanced to elite level (ITN) performed an incremental on-court specific endurance tennis test to exhaustion to determine maximal oxygen uptake (VO2max) and the first and second ventilatory thresholds (VT1, VT2). Ventilatory and gas exchange parameters were monitored using a telemetric portable gas analyser (K4 b2, Cosmed, Rome, Italy). Two weeks later the participants played a simulated tennis set against an opponent of similar level. Intensity zones (1: low, 2: moderate, and 3: high) were delimited by the individual VO2 values corresponding to VT1 and VT2, and expressed as percentage of maximum VO2 and heart rate. When expressed relative to VO2max, percentage of playing time in zone 1 (77 ± 25%) was significantly higher (p < 0.001) than in zone 2 (20 ± 21%) and zone 3 (3 ± 5%). Moderate to high positive correlations were found between VT1, VT2 and VO2max, and the percentage of playing time spent in zone 1 (r = 0.68–0.75), as well as low to high inverse correlations between the metabolic variables and the percentage of time spent in zone 2 and 3 (r = -0.49–0.75). Players with better aerobic fitness play at relatively lower intensities. We conclude that players spent more than 75% of the time in their low-intensity zone, with less than 25% of the time spent at moderate to high intensities. Aerobic fitness appears to determine the metabolic intensity that players can sustain throughout the game. PMID:26098638
Fornasiero, Alessandro; Savoldelli, Aldo; Fruet, Damiano; Boccia, Gennaro; Pellegrini, Barbara; Schena, Federico
2018-06-01
The aims of the study were to describe the physiological profile of a 65-km (4000-m cumulative elevation gain) running mountain ultra-marathon (MUM) and to identify predictors of MUM performance. Twenty-three amateur trail-runners performed anthropometric evaluations and an uphill graded exercise test (GXT) for VO 2max, ventilatory thresholds (VTs), power outputs (PMax, PVTs) and heart rate response (HRmax, HR@VTs). Heart rate (HR) was monitored during the race and intensity was expressed as: Zone I (
The development of rating of perceived exertion-based tests of physical working capacity.
Mielke, Michelle; Housh, Terry J; Malek, Moh H; Beck, Travis W; Schmidt, Richard J; Johnson, Glen O
2008-01-01
The purpose of the present study was to use ratings of perceived exertion (RPE) from the Borg (6-20) and OMNI-Leg (0-10) scales to determine the Physical Working Capacity at the Borg and OMNI thresholds (PWC(BORG) and PWC(OMNI)). PWC(BORG) and PWC(OMNI) were compared with other fatigue thresholds determined from the measurement of heart rate (the Physical Working Capacity at the Heart Rate Threshold: PWC(HRT)), and oxygen consumption (the Physical Working Capacity at the Oxygen Consumption Threshold, PWC(VO2)), as well as the ventilatory threshold (VT). Fifteen men and women volunteers (mean age +/- SD = 22 +/- 1 years) performed an incremental test to exhaustion on an electronically braked ergometer for the determination of VO2 peak and VT. The subjects also performed 4 randomly ordered workbouts to exhaustion at different power outputs (ranging from 60 to 206W) for the determination of PWC(BORG), PWC(OMNI), PWC(HRT), and PWC(VO2). The results indicated that there were no significant mean differences among the fatigue thresholds: PWC(BORG) (mean +/- SD = 133 +/- 37W; 67 +/- 8% of VO2 peak), PWC(OMNI) (137 +/- 44W; 68 +/- 9% of VO2 peak), PWC(HRT) (135 +/- 36W; 68 +/- 8% of VO2 peak), PWC(VO2) (145 +/- 41W; 72 +/- 7% of VO2 peak) and VT (131 +/- 45W; 66 +/- 8% of VO2 peak). The results of this study indicated that the mathematical model used to estimate PWC(HRT) and PWC(VO2) can be applied to ratings of perceived exertion to determine PWC(BORG) and PWC(OMNI) during cycle ergometry. Salient features of the PWC(BORG) and PWC(OMNI) tests are that they are simple to administer and require the use of only an RPE scale, a stopwatch, and a cycle ergometer. Furthermore, the power outputs at the PWC(BORG) and PWC(OMNI) may be useful to estimate the VT noninvasively and without the need for expired gas analysis.
See hear: psychological effects of music and music-video during treadmill running.
Hutchinson, Jasmin C; Karageorghis, Costas I; Jones, Leighton
2015-04-01
There is a paucity of work addressing the distractive, affect-enhancing, and motivational influences of music and video in combination during exercise. We examined the effects of music and music-and-video on a range of psychological and psychophysical variables during treadmill running at intensities above and below ventilatory threshold (VT). Participants (N = 24) exercised at 10 % of maximal capacity below VT and 10 % above under music-only, music-and-video, and control conditions. There was a condition × intensity × time interaction for perceived activation and state motivation, and an intensity × time interaction for state attention, perceived exertion (RPE), and affective valence. The music-and-video condition elicited the highest levels of dissociation, lowest RPE, and most positive affective responses regardless of exercise intensity. Attentional manipulations influence psychological and psychophysical variables at exercise intensities above and below VT, and this effect is enhanced by the combined presentation of auditory and visual stimuli.
Effect of CO₂ on the ventilatory sensitivity to rising body temperature during exercise.
Hayashi, Keiji; Honda, Yasushi; Miyakawa, Natsuki; Fujii, Naoto; Ichinose, Masashi; Koga, Shunsaku; Kondo, Narihiko; Nishiyasu, Takeshi
2011-05-01
We examined the degree to which ventilatory sensitivity to rising body temperature (the slope of the regression line relating ventilation and body temperature) is altered by restoration of arterial PCO(2) to the eucapnic level during prolonged exercise in the heat. Thirteen subjects exercised for ~60 min on a cycle ergometer at 50% of peak O(2) uptake with and without inhalation of CO(2)-enriched air. Subjects began breathing CO(2)-enriched air at the point that end-tidal Pco(2) started to decline. Esophageal temperature (T(es)), minute ventilation (V(E)), tidal volume (V(T)), respiratory frequency (f(R)), respiratory gases, middle cerebral artery blood velocity, and arterial blood pressure were recorded continuously. When V(E), V(T), f(R), and ventilatory equivalents for O(2) uptake (V(E)/VO(2)) and CO(2) output (V(E)/VCO(2)) were plotted against changes in T(es) from the start of the CO(2)-enriched air inhalation (ΔT(es)), the slopes of the regression lines relating V(E), V(T), V(E)/VO(2), and V(E)/VCO(2) to ΔT(es) (ventilatory sensitivity to rising body temperature) were significantly greater when subjects breathed CO(2)-enriched air than when they breathed room air (V(E): 19.8 ± 10.3 vs. 8.9 ± 6.7 l·min(-1)·°C(-1), V(T): 18 ± 120 vs. -81 ± 92 ml/°C; V(E)/VO(2): 7.4 ± 5.5 vs. 2.6 ± 2.3 units/°C, and V(E)/VCO(2): 7.6 ± 6.6 vs. 3.4 ± 2.8 units/°C). The increase in Ve was accompanied by increases in V(T) and f(R). These results suggest that restoration of arterial PCO(2) to nearly eucapnic levels increases ventilatory sensitivity to rising body temperature by around threefold.
Rodríguez-Marroyo, J A; Villa, J G; López-Satue, J; Pernía, R; Carballo, B; García-López, J; Foster, C
2011-11-01
The aim of this study was to analyse the physiological strain of firefighters, using heart rate (HR) and core temperature, during real wildfire suppression according to the type of attack performed (direct, indirect or mixed). Three intensity zones were established according to the HR corresponding to the ventilatory threshold (VT) and respiratory compensation threshold (RCT): zone 1,
Espada, Mario C; Reis, Joana F; Almeida, Tiago F; Bruno, Paula M; Vleck, Veronica E; Alves, Francisco B
2015-10-01
The purpose of this study was to understand the ventilatory and physiological responses immediately below and above the maximal lactate steady-state (MLSS) velocity and to determine the relationship of oxygen uptake (VO2) kinetics parameters with performance, in swimmers. Competitive athletes (N = 12) completed in random order and on different days a 400-m all-out test, an incremental step test comprising 5 × 250- and 1 × 200-m stages and 30 minutes at a constant swimming velocity (SV) at 87.5, 90, and 92.5% of the maximal aerobic velocity for MLSS velocity (MLSSv) determination. Two square-wave transitions of 500 m, 2.5% above and below the MLSSv were completed to determine VO2 on-kinetics. End-exercise VO2 at 97.5 and 102.5% of MLSSv represented, respectively, 81 and 97% of VO2max; the latter was not significantly different from maximal VO2 (VO2max). The VO2 at MLSSv (49.3 ± 9.2 ml·kg(-1)·min(-1)) was not significantly different from the second ventilatory threshold (VT2) (51.3 ± 7.6 ml·kg(-1)·min(-1)). The velocity associated with MLSS seems to be accurately estimated by the SV at VT2 (vVT2), and vVO2max also seems to be estimated with accuracy from the central 300-m mean velocity of a 400-m trial, indicators that represent a helpful tool for coaches. The 400-m swimming performance (T400) was correlated with the time constant of the primary phase VO2 kinetics (τp) at 97.5% MLSSv, and T800 was correlated with τp in both 97.5 and 102.5% of MLSSv. The assessment of the VO2 kinetics in swimming can help coaches to build training sets according to a swimmer's individual physiological response.
Marques-Neto, Silvio R; Maior, Alex S; Maranhão Neto, Geraldo A; Santos, Edil L
2012-07-01
Many studies have used the heart rate deflection points (HRDPs) during incremental exercise tests, because of their strong correlation with the anaerobic threshold. The aim of this study was to evaluate the profile of the HRDPs identified by a computerized method and compare them with ventilatory and lactate thresholds. Twenty-four professional soccer players (age, 22 ± 5 years; body mass, 74 ± 7 kg; height 177 ± 7 cm) volunteered for the study. The subjects completed a Bruce-protocol incremental treadmill exercise test to volitional fatigue. Heart rate (HR) and alveolar gas exchange were recorded continuously at ≥1 Hz during exercise testing. Subsequently, the time course of the HR was fit by a computer algorithm, and a set of lines yielding the lowest pooled residual sum of squares was chosen as the best fit. This procedure defined 2 HRDPs (HRDP1 and HRDP2). The HR break points averaged 43.9 ± 5.9 and 89.7 ± 7.5% of the VO2peak. The HRDP1 showed a poor correlation with ventilatory threshold (VT; r = 0.50), but HRDP2 was highly correlated to the respiratory compensation (RC) point (r = 0.98). Neither HRDP1 nor HRDP2 was correlated with LT1 (at VO2 = 2.26 ± 0.72 L·min(-1); r = 0.26) or LT2 (2.79 ± 0.59 L·min(-1); r = 0.49), respectively. LT1 and LT2 also were not well correlated with VT (2.93 ± 0.68 L·min(-1); r = 0.20) or RC (3.82 ± 0.60 L·min(-1); r = 0.58), respectively. Although the HR deflection points were not correlated to LT, HRDP2 could be identified in all the subjects and was strongly correlated with RC, consistent with a relationship to cardiorespiratory fatigue and endurance performance.
Smith, Ashleigh E; Eston, Roger; Tempest, Gavin D; Norton, Belinda; Parfitt, Gaynor
2015-09-01
The American College of Sports Medicine has highlighted the importance of considering the physiological and affective responses to exercise when setting exercise intensity. Here, we examined the relationship between exercise intensity and physiological and affective responses in active older adults. Eighteen participants (60-74 years; 64.4 ± 3.9; 8 women) completed a maximal graded exercise test (GXT) on a treadmill. Since time to exhaustion in the GXT differed between participants, heart rate (HR), oxygen consumption (VO2), affective valence (affect) and rating of perceived exertion (RPE) were expressed relative to the individually determined ventilatory threshold (%atVT). During the GXT, VO2, HR and RPE increased linearly (all P < 0.01). Affect declined initially (but remained positive) (P = 0.03), stabilised around VT (still positive) (P > 0.05) and became negative towards the end of the test (P < 0.01). In a subsequent session, participants completed a 20-min bout of self-selected exercise (at a preferred intensity). Initially, participants chose to exercise below VT (88.2 ± 17.4 %VO2atVT); however, the intensity was adjusted to work at, or above VT (107.7 ± 19.9 %VO2atVT) after 10 min (P < 0.001), whilst affect remained positive. Together, these findings indicate that exercise around VT, whether administered during an exercise test, or self-selected by the participant, is likely to result in positive affective responses in older adults.
Affect, exercise, and physical activity among healthy adolescents.
Schneider, Margaret; Dunn, Andrea; Cooper, Daniel
2009-12-01
Many adolescents do not meet public health recommendations for moderate-to-vigorous physical activity (MVPA). In studies of variables influencing adolescent MVPA, one that has been understudied is the affective response to exercise. We hypothesized that adolescents with a more positive affective response to acute exercise would be more active. Adolescents (N = 124; 46% male) completed two 30-min exercise tasks (above and below the ventilatory threshold [VT]), and wore ActiGraph accelerometers for 6.5 +/- 0.7 days. Affective valence was assessed before, during, and after each task. A more positive affective response during exercise below the VT was associated with greater participation in MVPA (p < .05). The results are consistent with the hypothesis that individuals who have a more positive affective response to exercise will engage in more MVPA. To promote greater participation in MVPA among adolescents, programs should be designed to facilitate a positive affective experience during exercise.
Alkhatib, Ahmad
2015-01-01
Sedentariness and physical inactivity are often reported within white-collar workers, including university campus employees. However, the prevalence of the associated sedentary risk factors and risk reduction intervention strategies within a university campus workplace are less known. This study investigates whether the prevalence of sedentary risk factors within university campus employees could be reduced with a campus based exercise intervention. 56 UK university employees (age = 50.7 ± 10.2, stature = 1.68.8 ± 8.6, body mass = 73.9 ± 15.1) were tested for body mass index (BMI), systolic blood pressure (SBP), diastolic blood pressure (DBP) and maximal cardiorespiratory capacity (V̇O2max). The prevalence was analyzed across genders and job roles. An exercise intervention followed for the sedentary employees involving walking and running for 25 min twice/week for 10 weeks at an intensity corresponding to individual's ventilatory threshold (VT). The university workplace demonstrated a prevalence of higher BMI, SBP and DBP than the recommended healthy thresholds, with gender having a significant effect. Males' BMI, SBP and DBP were higher than in females (p < 0.05) and males' V̇O2max was lower than the recommended healthy thresholds. The exercise training intervention significantly improved V̇O2max, VT and VT velocity in both genders (all p < 0.05) with both groups meeting the recommended thresholds following the intervention. University campus employees have a high prevalence of sedentary risk factors across different genders and job roles. These risks can be reduced by an exercise-based intervention administered within the campus workplace, which should be considered in university workplace policies.
Influence of Training Load and Altitude on HRV Fatigue Patterns in Elite Nordic Skiers.
Schmitt, Laurent; Regnard, Jacques; Coulmy, Nicolas; Millet, Gregoire P
2018-06-14
We aimed to analyse the relationship between training load/intensity and different heart rate variability (HRV) fatigue patterns in 57 elite Nordic-skiers. 1063 HRV tests were performed during 5 years. R-R intervals were recorded in resting supine (SU) and standing (ST) positions. Heart rate, low (LF), high (HF) frequency powers of HRV were determined. Training volume, training load (TL, a.u.) according to ventilatory threshold 1 (VT1) and VT2 were measured in zones I≤VT1; VT1
Tempest, Gavin D; Parfitt, Gaynor
2017-07-01
The interplay between the prefrontal cortex and amygdala is proposed to explain the regulation of affective responses (pleasure/displeasure) during exercise as outlined in the dual-mode model. However, due to methodological limitations the dual-mode model has not been fully tested. In this study, prefrontal oxygenation (using near-infrared spectroscopy) and amygdala activity (reflected by eyeblink amplitude using acoustic startle methodology) were recorded during exercise standardized to metabolic processes: 80% of ventilatory threshold (below VT), at the VT, and at the respiratory compensation point (RCP). Self-reported tolerance of the intensity of exercise was assessed prior to, and affective responses recorded during exercise. The results revealed that, as the intensity of exercise became more challenging (from below VT to RCP), prefrontal oxygenation was larger and eyeblink amplitude and affective responses were reduced. Below VT and at VT, larger prefrontal oxygenation was associated with larger eyeblink amplitude. At the RCP, prefrontal oxygenation was greater in the left than right hemisphere, and eyeblink amplitude explained significant variance in affective responses (with prefrontal oxygenation) and self-reported tolerance. These findings highlight the role of the prefrontal cortex and potentially the amygdala in the regulation of affective (particularly negative) responses during exercise at physiologically challenging intensities (above VT). In addition, a psychophysiological basis of self-reported tolerance is indicated. This study provides some support of the dual-mode model and insight into the neural basis of affective responses during exercise. © 2017 Society for Psychophysiological Research.
Skucas, Kestutis; Pokvytyte, Vaida
2017-04-01
The aim of this paper was to investigate the effect of short-term period, moderate intensity and high volume endurance training on physiological variables in elite wheelchair basketball players. Eight wheelchair basketball players were examined. The subjects participated in a two-week intervention program of mainly two training types: wheelchair basketball and wheelchair driving endurance training. The subjects performed the continuously increasing cycling exercise (CCE) at the constant 60 rpm arm cranking speed at the beginning of the program and after two weeks of the program. The initial workload was 20 W, then the workload was increased by 2 W every 5 seconds until fatigue. The post training of the wheelchair basketball group in the study showed a significant improvement in the peak oxygen uptake (VO2peak) and the peak power output (POpeak). VO2peak increased by 9% from 2.32±0.16 L/min to 2.53±0.2 L/min (P<0.05). POpeak increased by 28% from 141.75±14.23 W, to 181.63±26.3 W (P<0.05). The pre-training and post training test power output (PO [w]), relative power output (PO [w/kg]) increased significantly in all zones of energy production. In conclusion, this study indicated that the wheelchair basketball squad had relatively high levels of aerobic fitness prior to participating in the endurance training program. Nevertheless, the high-volume, moderate-intensity, short-term training program, which evolved over the two-weeks period, resulted in the improvement of the athlete's aerobic endurance. The ventilatory threshold (VT) and the second ventilatory threshold (VT2) are good markers for aerobic capacity of wheelchair athletes.
Self-reported tolerance influences prefrontal cortex hemodynamics and affective responses.
Tempest, Gavin; Parfitt, Gaynor
2016-02-01
The relationship between cognitive and sensory processes in the brain contributes to the regulation of affective responses (pleasure-displeasure). Exercise can be used to manipulate sensory processes (by increasing physiological demand) in order to examine the role of dispositional traits that may influence an individual's ability to cognitively regulate these responses. With the use of near infrared spectroscopy, in this study we examined the influence of self-reported tolerance upon prefrontal cortex (PFC) hemodynamics and affective responses. The hemodynamic response was measured in individuals with high or low tolerance during an incremental exercise test. Sensory manipulation was standardized against metabolic processes (ventilatory threshold [VT] and respiratory compensation point [RCP]), and affective responses were recorded. The results showed that the high-tolerance group displayed a larger hemodynamic response within the right PFC above VT (which increased above RCP). The low-tolerance group showed a larger hemodynamic response within the left PFC above VT. The high-tolerance group reported a more positive/less negative affective response above VT. These findings provide direct neurophysiological evidence of differential hemodynamic responses within the PFC that are associated with tolerance in the presence of increased physiological demands. This study supports the role of dispositional traits and previous theorizing into the underlying mechanisms (cognitive vs. sensory processes) of affective responses.
Durkalec-Michalski, Krzysztof; Zawieja, Emilia E; Podgórski, Tomasz; Łoniewski, Igor; Zawieja, Bogna E; Warzybok, Marta; Jeszka, Jan
2018-01-01
Sodium bicarbonate (SB) has been proposed as an ergogenic aid, as it improves high-intensity and resistance exercise performance. However, no studies have yet investigated SB application in CrossFit. This study examined the effects of chronic, progressive-dose SB ingestion on CrossFit-like performance and aerobic capacity. In a randomized, double-blind, cross-over trial, 21 CrossFit-trained participants were randomly allocated to 2 groups and underwent 2 trials separated by a 14-day washout period. Participants ingested either up to 150 mg∙kg-1 of SB in a progressive-dose regimen or placebo for 10 days. Before and after each trial, Fight Gone Bad (FGB) and incremental cycling (ICT) tests were performed. In order to examine biochemical responses, blood samples were obtained prior to and 3 min after completing each exercise test. No gastrointestinal (GI) side effects were reported during the entire protocol. The overall FGB performance improved under SB by ~6.1% (p<0.001) and it was ~3.1% higher compared to post placebo (PLApost) (p = 0.040). The number of repetitions completed in each round also improved under SB (mean from baseline: +5.8% to +6.4%). Moreover, in ICT, the time to ventilatory threshold (VT) (~8:25 min SBpost vs. ~8:00 min PLApost, p = 0.020), workload at VT (~218 W SBpost vs. ~208 W PLApost, p = 0.037) and heart rate at VT (~165 bpm SBpost vs. ~161 bpm PLApost, p = 0.030) showed higher SBpost than PLApost. Furthermore, the maximum carbon dioxide production increased under SB by ~4.8% (from ~3604 mL∙min-1 to ~3776 mL∙min-1, p = 0.049). Pyruvate concentration and creatine kinase activity before ICT showed higher SBpost than PLApost (~0.32 mmol∙L-1 vs. ~0.26 mmol∙L-1, p = 0.001; ~275 U∙L-1 vs. ~250 U∙L-1, p = 0.010, respectively). However, the small sample size limits the wide-application of our results. Progressive-dose SB ingestion regimen eliminated GI side effects and improved CrossFit-like performance, as well as delayed ventilatory threshold occurrence.
Breathing mechanics during exercise with added dead space reflect mechanisms of ventilatory control.
Wood, Helen E; Mitchell, Gordon S; Babb, Tony G
2009-09-30
Small increases in external dead space (V(D)) augment the exercise ventilatory response via a neural mechanism known as short-term modulation (STM). We hypothesized that breathing mechanics would differ during exercise, increased V(D) and STM. Men were studied at rest and during cycle exercise (10-50W) without (Control) and with added V(D) (200-600ml). With added V(D), V(T) increased via increased end-inspiratory lung volume (EILV), with no change in end-expiratory lung volume (EELV), indicating recruitment of inspiratory muscles only. With exercise, V(T) increased via both decreased EELV and increased EILV, indicating recruitment of both expiratory and inspiratory muscles. A significant interaction between the effects of exercise and V(D) on mean inspiratory flow indicated that the augmented exercise ventilatory response with added V(D) (i.e. STM) resulted from increased drive to the inspiratory muscles. These results reveal different patterns of respiratory muscle recruitment among experimental conditions. Hence, we conclude that fundamental differences exist in the neural control of ventilatory responses during exercise, increased V(D) and STM.
Intensity related changes of running economy in recreational level distance runners.
Engeroff, Tobias; Bernardi, Andreas; Niederer, Daniel; Wilke, Jan; Vogt, Lutz; Banzer, Winfried
2017-09-01
Running economy (RE) is often described as a key demand of running performance. The variety of currently used assessment methods with different running intensities and outcomes restricts interindividual comparability of RE in recreational level runners. The purpose of this study was to compare the influence of RE, assessed as oxygen cost (OC) and caloric unit cost (CUC), on running speed at individual physiological thresholds. Eighteen recreational runners performed: 1) a graded exercise test to estimate first ventilatory threshold (VT1), respiratory compensation point (RCP) and maximal oxygen uptake (VO2max); 2) discontinuous RE assessment to determine relative OC in milliliters per kilogram per kilometer (mL/kg/km) and CUC in kilocalories per kilogram per kilometer (kcal/kg/km) at three different running intensities: VT1, RCP and at a third standardized reference point (TP) in between. OC (mL/kg/km; at VT1: 235.4±26.2; at TP: 227.8±23.4; at RCP: 224.9±21.9) and CUC (kcal/kg/km at VT1: 1.18±0.13; at TP: 1.14±0.12; at RCP: 1.13±0.11) decreased with increasing intensities (P≤0.01). Controlling for the influence of sex OC and CUC linearly correlated with running speed at RCP and VO2max (P≤0.01). RE, even assessed at low intensity, is strongly related to running performance in recreational athletes. Both calculation methods used (OC and CUC) are sensitive for monitoring intensity related changes of substrate utilization. RE values decreased with higher running intensity indicating an increase of anaerobic and subsequent decrease of aerobic substrate utilization.
Cardiorespiratory demands during an inline speed skating marathon race: a case report.
Stangier, Carolin; Abel, Thomas; Mierau, Julia; Hollmann, Wildor; Strüder, Heiko K
2016-09-01
This study was designed to investigate the intensity profile during an inline speed skating marathon road race. A highly-trained male athlete (20 y, 73.4 kg, 178 cm, V̇O2 peak: 60.8 mL·kg-1·min-1) participated in a marathon road race. Oxygen uptake (V̇O2), respiratory exchange ratio (RER), heart rate (HR) and speed were measured using a portable gas analysis system with a HR monitor and GPS-Sensor integrated. The athlete´s peak V̇O2, HR and speed at ventilatory thresholds were assessed during an incremental field test (22 km·h-1, increase 2 km·h-1 every 5 min) one week before the race. During the race, the absolute time spent in the "easy intensity zone" (V̇O2 below VT1) was 1 min, 49 min "moderate intensity zone" (V̇O2 between VT1 and VT2), and 26 min in the "hard intensity zone" (V̇O2 above VT2). The average HR was 171±6 bpm, corresponding to 95% of the maximum. This study shows that inline speed skating road races over a marathon are conducted at moderate to high V̇O2 and heart rate levels. The physiological racing pattern is very intermittent, requiring both a high level of aerobic and anaerobic capacity.
Taylor, Natalie C; Li, Aihua; Nattie, Eugene E
2005-07-15
Serotonergic neurones in the mammalian medullary raphe region (MRR) have been implicated in central chemoreception and the modulation of the ventilatory response to hypercapnia, and may also be involved in the ventilatory response to hypoxia. In this study, we ask whether ventilatory responses across arousal states are affected when the 5-hydroxytryptamine 1A receptor (5-HT1A) agonist (R)-(+)-8-hydroxy-2(di-n-propylamino)tetralin (DPAT) is microdialysed into the MRR of the unanaesthetized adult rat. Microdialysis of 1, 10 and 30 mM DPAT into the MRR significantly decreased absolute ventilation values(VE) during 7% CO2 breathing by 21%, 19% and 30%, respectively, in wakefulness compared to artificial cerebrospinal fluid (aCSF) microdialysis, due to decreases in tidal volume (VT) and not in frequency (f), similar to what occurred during non-rapid eye movement (NREM) sleep. The concentration-dependence of the hypercapnic ventilatory effect might be due to differences in tissue distribution of DPAT. DPAT (30 mM) changed room air breathing pattern by increasing f and decreasing VT. As evidenced by a sham control group, repeated experimentation and microdialysis of aCSF alone had no effect on the ventilatory response to 7% CO2 during wakefulness or sleep. Unlike during hypercapnia, microdialysis of 30 mM DPAT into the MRR did not change the ventilatory response to 10% O2. Additionally, 10 and 30 mM DPAT MRR microdialysis decreased body temperature, and 30 mM DPAT increased the percentage of experimental time in wakefulness. We conclude that serotonergic activity in the MRR plays a role in the ventilatory response to hypercapnia, but not to hypoxia, and that MRR 5-HT1A receptors are also involved in thermoregulation and arousal.
Maximal lactate steady state determination with a single incremental test exercise.
Laplaud, David; Guinot, Michel; Favre-Juvin, Anne; Flore, Patrice
2006-03-01
The aim of this study was to determine whether the power output associated with a maximal lactate steady state (MLSS) (.W(MLSS)) can be assessed using a single incremental cycling test. Eleven recreational sportsmen (age: 22+/-1 years, height: 175+/-6 cm, weight: 71+/-5 kg) volunteered to participate in the study. For each subject the first and second ventilatory thresholds (VT(1) and VT(2), respectively) and the power output corresponding to (respiratory exchange ratio) RER=1.00 were determined during an incremental test to exhaustion. Thereafter, each subject performed several 30-min constant load tests to determine MLSS. The workload used in the first constant test was set to the .W(RER=1.00) determined during the incremental test. .W(VT1) (175+/-24 W) and .W(VT2) (265+/-31 W) were significantly different from .W(MLSS )(220+/-36 W). Whereas, .W(RER=1.00) (224+/-33 W) was similar to .W(MLSS). HR, RER and .VE were significantly different between the 10th and the 30th minutes when exercising at .W(RER=1.00) and at .W(MLSS). In contrast, .VO(2) and .VCO(2) were stable over those 30-min constant tests. Power output at VT(1), RER=1.00 and VT(2) were all correlated to .W(MLSS) but the relationship was stronger between RER=1.00 and MLSS (R (2)=0.95). The present study shows that the power output associated with a RER value equal to 1.00 during an incremental test does not differ from that determined for MLSS. Hence, the MLSS can be estimated with a single exercise test.
Differences in Pedaling Technique in Cycling: A Cluster Analysis.
Lanferdini, Fábio J; Bini, Rodrigo R; Figueiredo, Pedro; Diefenthaeler, Fernando; Mota, Carlos B; Arndt, Anton; Vaz, Marco A
2016-10-01
To employ cluster analysis to assess if cyclists would opt for different strategies in terms of neuromuscular patterns when pedaling at the power output of their second ventilatory threshold (PO VT2 ) compared with cycling at their maximal power output (PO MAX ). Twenty athletes performed an incremental cycling test to determine their power output (PO MAX and PO VT2 ; first session), and pedal forces, muscle activation, muscle-tendon unit length, and vastus lateralis architecture (fascicle length, pennation angle, and muscle thickness) were recorded (second session) in PO MAX and PO VT2 . Athletes were assigned to 2 clusters based on the behavior of outcome variables at PO VT2 and PO MAX using cluster analysis. Clusters 1 (n = 14) and 2 (n = 6) showed similar power output and oxygen uptake. Cluster 1 presented larger increases in pedal force and knee power than cluster 2, without differences for the index of effectiveness. Cluster 1 presented less variation in knee angle, muscle-tendon unit length, pennation angle, and tendon length than cluster 2. However, clusters 1 and 2 showed similar muscle thickness, fascicle length, and muscle activation. When cycling at PO VT2 vs PO MAX , cyclists could opt for keeping a constant knee power and pedal-force production, associated with an increase in tendon excursion and a constant fascicle length. Increases in power output lead to greater variations in knee angle, muscle-tendon unit length, tendon length, and pennation angle of vastus lateralis for a similar knee-extensor activation and smaller pedal-force changes in cyclists from cluster 2 than in cluster 1.
Hyodo, Kazuki; Dan, Ippeita; Kyutoku, Yasushi; Suwabe, Kazuya; Byun, Kyeongho; Ochi, Genta; Kato, Morimasa; Soya, Hideaki
2016-01-15
Previous studies have shown that higher aerobic fitness is related to higher cognitive function and higher task-related prefrontal activation in older adults. However, a holistic picture of these factors has yet to be presented. As a typical age-related change of brain activation, less lateralized activity in the prefrontal cortex during cognitive tasks has been observed in various neuroimaging studies. Thus, this study aimed to reveal the relationship between aerobic fitness, cognitive function, and frontal lateralization. Sixty male older adults each performed a submaximal incremental exercise test to determine their oxygen intake (V·O2) at ventilatory threshold (VT) in order to index their aerobic fitness. They performed a color-word Stroop task while prefrontal activation was monitored using functional near infrared spectroscopy. As an index of cognitive function, Stroop interference time was analyzed. Partial correlation analyses revealed significant correlations among higher VT, shorter Stroop interference time and greater left-lateralized dorsolateral prefrontal cortex (DLPFC) activation when adjusting for education. Moreover, mediation analyses showed that left-lateralized DLPFC activation significantly mediated the association between VT and Stroop interference time. These results suggest that higher aerobic fitness is associated with cognitive function via lateralized frontal activation in older adults. Copyright © 2015 Elsevier Inc. All rights reserved.
Zawieja, Emilia E.; Podgórski, Tomasz; Łoniewski, Igor; Zawieja, Bogna E.
2018-01-01
Background Sodium bicarbonate (SB) has been proposed as an ergogenic aid, as it improves high-intensity and resistance exercise performance. However, no studies have yet investigated SB application in CrossFit. This study examined the effects of chronic, progressive-dose SB ingestion on CrossFit-like performance and aerobic capacity. Methods In a randomized, double-blind, cross-over trial, 21 CrossFit-trained participants were randomly allocated to 2 groups and underwent 2 trials separated by a 14-day washout period. Participants ingested either up to 150 mg∙kg-1 of SB in a progressive-dose regimen or placebo for 10 days. Before and after each trial, Fight Gone Bad (FGB) and incremental cycling (ICT) tests were performed. In order to examine biochemical responses, blood samples were obtained prior to and 3 min after completing each exercise test. Results No gastrointestinal (GI) side effects were reported during the entire protocol. The overall FGB performance improved under SB by ~6.1% (p<0.001) and it was ~3.1% higher compared to post placebo (PLApost) (p = 0.040). The number of repetitions completed in each round also improved under SB (mean from baseline: +5.8% to +6.4%). Moreover, in ICT, the time to ventilatory threshold (VT) (~8:25 min SBpost vs. ~8:00 min PLApost, p = 0.020), workload at VT (~218 W SBpost vs. ~208 W PLApost, p = 0.037) and heart rate at VT (~165 bpm SBpost vs. ~161 bpm PLApost, p = 0.030) showed higher SBpost than PLApost. Furthermore, the maximum carbon dioxide production increased under SB by ~4.8% (from ~3604 mL∙min-1 to ~3776 mL∙min-1, p = 0.049). Pyruvate concentration and creatine kinase activity before ICT showed higher SBpost than PLApost (~0.32 mmol∙L-1 vs. ~0.26 mmol∙L-1, p = 0.001; ~275 U∙L-1 vs. ~250 U∙L-1, p = 0.010, respectively). However, the small sample size limits the wide-application of our results. Conclusions Progressive-dose SB ingestion regimen eliminated GI side effects and improved CrossFit-like performance, as well as delayed ventilatory threshold occurrence. PMID:29771966
Noninvasive method to estimate anaerobic threshold in individuals with type 2 diabetes.
Sales, Marcelo M; Campbell, Carmen Sílvia G; Morais, Pâmella K; Ernesto, Carlos; Soares-Caldeira, Lúcio F; Russo, Paulo; Motta, Daisy F; Moreira, Sérgio R; Nakamura, Fábio Y; Simões, Herbert G
2011-01-12
While several studies have identified the anaerobic threshold (AT) through the responses of blood lactate, ventilation and blood glucose others have suggested the response of the heart rate variability (HRV) as a method to identify the AT in young healthy individuals. However, the validity of HRV in estimating the lactate threshold (LT) and ventilatory threshold (VT) for individuals with type 2 diabetes (T2D) has not been investigated yet. To analyze the possibility of identifying the heart rate variability threshold (HRVT) by considering the responses of parasympathetic indicators during incremental exercise test in type 2 diabetics subjects (T2D) and non diabetics individuals (ND). Nine T2D (55.6 ± 5.7 years, 83.4 ± 26.6 kg, 30.9 ± 5.2 kg.m2(-1)) and ten ND (50.8 ± 5.1 years, 76.2 ± 14.3 kg, 26.5 ± 3.8 kg.m2(-1)) underwent to an incremental exercise test (IT) on a cycle ergometer. Heart rate (HR), rate of perceived exertion (RPE), blood lactate and expired gas concentrations were measured at the end of each stage. HRVT was identified through the responses of root mean square successive difference between adjacent R-R intervals (RMSSD) and standard deviation of instantaneous beat-to-beat R-R interval variability (SD1) by considering the last 60 s of each incremental stage, and were known as HRVT by RMSSD and SD1 (HRVT-RMSSD and HRVT-SD1), respectively. No differences were observed within groups for the exercise intensities corresponding to LT, VT, HRVT-RMSSD and HHVT-SD1. Furthermore, a strong relationship were verified among the studied parameters both for T2D (r = 0.68 to 0.87) and ND (r = 0.91 to 0.98) and the Bland & Altman technique confirmed the agreement among them. The HRVT identification by the proposed autonomic indicators (SD1 and RMSSD) were demonstrated to be valid to estimate the LT and VT for both T2D and ND.
Lofrano-Prado, Mara Cristina; Hill, James O; Silva, Humberto José Gomes; Freitas, Camila Rodrigues Menezes; Lopes-de-Souza, Sandra; Lins, Tatiana Acioli; do Prado, Wagner Luiz
2012-04-03
The aim of this study was to determine the acute effects of exercise intensity on anxiety, mood states and hunger in obese adolescents. Subjects were eight male obese adolescents (age 15.44 ± 2.06 y; BMI 33.06 ± 4.78 kg/m2). Each subject underwent three experimental trials: (1) Control, seated for 30 min; (2) Low intensity exercise (LIE)--exercise at 10% below ventilatory threshold (VT); (3) High intensity exercise (HIE)--exercise at 10% above VT. Anxiety (STAI Trait/State), mood (POMS) and hunger (VAS) were assessed before and immediately after the experimental sessions. Comparisons between trials and times were assessed using Kruskal-Wallis and Wilcoxon tests, respectively. Associations between variables were described using a Spearman test. The largest increase in hunger was observed after LEI (914.22%). Both exercise sessions increased anxiety, fatigue and decreased vigor (p < 0.05). Acute exercise bouts are associated with negative changes in anxiety and mood, and with increases in hunger in obese adolescents.
Oxygen consumption and heart rate responses to isolated ballet exercise sets.
Rodrigues-Krause, Josianne; Dos Santos Cunha, Giovani; Alberton, Cristine Lima; Follmer, Bruno; Krause, Mauricio; Reischak-Oliveira, Alvaro
2014-01-01
Ballet stage performances are associated with higher cardiorespiratory demand than rehearsals and classes. Hence, new interest is emerging to create periodized training that enhances dancers' fitness while minimizing delayed exercise-induced fatigue and possible injuries. Finding out in what zones of intensity dancers work during different ballet movements may support the use of supplemental training adjusted to the needs of the individual dancer. Therefore, the main purpose of this study was to describe dancers' oxygen consumption (VO2) and heart rate (HR) responses during the performance of nine isolated ballet exercise sets, as correlated with their first and second ventilatory thresholds (VT1 and VT2). Twelve female ballet dancers volunteered for the study. Their maximum oxygen consumption (VO2max), VT1, and VT2 were determined by use of an incremental treadmill test. Nine sets of ballet movements were assessed: pliés, tendus, jetés, rond de jambes, fondus, grand adage (adage), grand battements, temps levés, and sautés. The sets were randomly executed and separated by 5 minute rest periods. ANOVA for repeated measurements followed by the Bonferroni Post-hoc test were applied (p < 0.05). VO2 responses were as follows: pliés (17.6 ± 1.6 ml·kg(-1)·min(-1)); tendus and adage were not significantly greater than VT1; rond de jambes (21.8 ± 3.1 ml·kg(-1) ·min(-1)); fondus and jetés were higher than VT1 and the previous exercises; grand battements (25.8 ± 2.9 ml·kg(-1)·min(-1)) was greater than all the other exercises and VT1; and VT2 was significantly higher than all ballet sets. This stratification followed closely, but not exactly, the variation in HR. For example, rond de jambes (156.8 ± 19 b·min(-1)) did not show any significant difference from all the other ballet sets, nor VT1 or VT2. It is concluded that the workloads of isolated ballet sets, based on VO2 responses, vary between low and moderate aerobic intensity in relation to dancers' VT1 and VT2. However, ballet set workloads may be higher when based on HR responses, due to the intermittent and isometric components of dance.
Effects of Endurance Training at the Crossover Point in Women with Metabolic Syndrome.
Borel, Benoit; Coquart, Jérémy; Boitel, Guillaume; Duhamel, Alain; Matran, Régis; Delsart, Pascal; Mounier-Vehier, Claire; Garcin, Murielle
2015-11-01
On the basis of theoretical evidence, intensity at the crossover point (COP) of substrate utilization could be considered as potential exercise intensity for metabolic syndrome (MetS). This study aimed to examine the effects of a training program at COP on exercise capacity parameters in women with MetS and to compare two metabolic indices (COP and the maximal fat oxidation rate point LIPOXmax®) with ventilatory threshold (VT). Nineteen women with MetS volunteered to perform a 12-wk training program on a cycle ergometer, with intensity corresponding to COP. Pre- and posttraining values of anthropometric and exercise capacity parameters were compared to determine the effects of exercise training. The pre-post training change of COP, LIPOXmax®, and VT were also investigated. After training, anthropometric parameters were significantly modified, with reduction of body mass (3.0% ± 3.0%, P < 0.001), fat mass (3.3% ± 3.4%, P < 0.001), and body mass index (3.2% ± 3.4%, P < 0.001). Exercise capacity was improved after the training program, with significant increase of maximal power output (25.0% ± 18.4%, P < 0.001) and maximal oxygen uptake (V˙O2max, 9.0% ± 11.2%; P < 0.01). Lastly, when expressed in terms of power output, COP, LIPOXmax®, and VT occurred at a similar exercise intensity, but the occurrence of these three indices is different when expressed in terms of oxygen uptake, HR, or RPE. This study highlights the effectiveness of a 12-wk training program at COP to improve physical fitness in women with MetS. The relations between metabolic indices and VT in terms of power output highlight the determination of VT from a shorter maximal exercise as a useful method for determining metabolic indices in MetS.
Pinto, Stephanie S; Brasil, Roxana M; Alberton, Cristine L; Ferreira, Hector K; Bagatini, Natália C; Calatayud, Joaquin; Colado, Juan C
2016-02-01
This study compared heart rate (HR), oxygen uptake (VO2), percentage of maximal HR (%HRmax), percentage of maximal VO2, and cadence (Cad) related to the anaerobic threshold (AT) during a water cycling maximal test between heart rate deflection point (HRDP) and ventilatory (VT) methods. In addition, the correlations between both methods were assessed for all variables. The test was performed by 27 men in a cycle ergometer in an aquatic environment. The protocol started at a Cad of 100 b · min(-1) for 3 minutes with subsequent increments of 15 b · min(-1) every 2 minutes until exhaustion. A paired two-tailed Student's t-test was used to compare the variables between the HRDP and VT methods. The Pearson product-moment correlation test was used to correlate the same variables determined by the 2 methods. There was no difference in HR (166 ± 13 vs. 166 ± 13 b · min(-1)), VO2 (38.56 ± 6.26 vs. 39.18 ± 6.13 ml · kg(-1) · min(-1)), %HRmax (89.24 ± 3.84 vs. 89.52 ± 4.29%), VO2max (70.44 ± 7.99 vs. 71.64 ± 8.32%), and Cad (174 ± 14 b · min(-1) vs. 171 ± 8 b · min(-1)) related to AT between the HRDP and VT methods. Moreover, significant relationships were found between the methods to determine the AT for all variables analyzed (r = 0.57-0.97). The estimation of the HRDP may be a noninvasive and easy method to determine the AT, which could be used to adapt individualized training intensities to practitioners during water cycling classes.
Vivodtzev, Isabelle; Gagnon, Philippe; Pepin, Véronique; Saey, Didier; Laviolette, Louis; Brouillard, Cynthia; Maltais, François
2011-01-01
Rationale The endurance time (Tend) during constant-workrate cycling exercise (CET) is highly variable in COPD. We investigated pulmonary and physiological variables that may contribute to these variations in Tend. Methods Ninety-two patients with COPD completed a CET performed at 80% of peak workrate capacity (Wpeak). Patients were divided into tertiles of Tend [Group 1: <4 min; Group 2: 4–6 min; Group 3: >6 min]. Disease severity (FEV1), aerobic fitness (Wpeak, peak oxygen consumption [ peak], ventilatory threshold [ VT]), quadriceps strength (MVC), symptom scores at the end of CET and exercise intensity during CET (heart rate at the end of CET to heart rate at peak incremental exercise ratio [HRCET/HRpeak]) were analyzed as potential variables influencing Tend. Results Wpeak, peak, VT, MVC, leg fatigue at end of CET, and HRCET/HRpeak were lower in group 1 than in group 2 or 3 (p≤0.05). VT and leg fatigue at end of CET independently predicted Tend in multiple regression analysis (r = 0.50, p = 0.001). Conclusion Tend was independently related to the aerobic fitness and to tolerance to leg fatigue at the end of exercise. A large fraction of the variability in Tend was not explained by the physiological parameters assessed in the present study. Individualization of exercise intensity during CET should help in reducing variations in Tend among patients with COPD. PMID:21386991
Macananey, Oscar; O'Shea, Donal; Warmington, Stuart A; Green, Simon; Egaña, Mikel
2012-08-01
Supervised exercise (SE) in patients with type 2 diabetes improves oxygen uptake kinetics at the onset of exercise. Maintenance of these improvements, however, has not been examined when supervision is removed. We explored if potential improvements in oxygen uptake kinetics following a 12-week SE that combined aerobic and resistance training were maintained after a subsequent 12-week unsupervised exercise (UE). The involvement of cardiac output (CO) in these improvements was also tested. Nineteen volunteers with type 2 diabetes were recruited. Oxygen uptake kinetics and CO (inert gas rebreathing) responses to constant-load cycling at 50% ventilatory threshold (V(T)), 80% V(T), and mid-point between V(T) and peak workload (50% Δ) were examined at baseline (on 2 occasions) and following each 12-week training period. Participants decided to exercise at a local gymnasium during the UE. Thirteen subjects completed all the interventions. The time constant of phase 2 of oxygen uptake was significantly faster (p < 0.05) post-SE and post-UE compared with baseline at 50% V(T) (17.3 ± 10.7 s and 17.5 ± 5.9 s vs. 29.9 ± 10.7 s), 80% V(T) (18.9 ± 4.7 and 20.9 ± 8.4 vs. 34.3 ± 12.7s), and 50% Δ (20.4 ± 8.2 s and 20.2 ± 6.0 s vs. 27.6 ± 3.7 s). SE also induced faster heart rate kinetics at all 3 intensities and a larger increase in CO at 30 s in relation to 240 s at 80% V(T); and these responses were maintained post-UE. Unsupervised exercise maintained benefits in oxygen uptake kinetics obtained during a supervised exercise in subjects with diabetes, and these benefits were associated with a faster dynamic response of heart rate after training.
Ventilatory Patterning in a Mouse Model of Stroke
Koo, Brian B; Strohl, Kingman P; Gillombardo, Carl B; Jacono, Frank J
2010-01-01
Cheyne-Stokes respiration (CSR) is a breathing pattern characterized by waxing and waning of breath volume and frequency, and is often recognized following stroke, when causal pathways are often obscure. We used an animal model to address the hypothesis that cerebral infarction is a mechanism for producing breathing instability. Fourteen male A/J mice underwent either stroke (n=7) or sham (n=7) procedure. Ventilation was measured using whole body plethysmography. Respiratory rate (RR), tidal volume (VT) and minute ventilation (Ve) mean values and coefficient of variation were computed for ventilation and oscillatory behavior. In addition, the ventilatory data were computationally fit to models to quantify autocorrelation, mutual information, sample entropy and a nonlinear complexity index. At the same time post procedure, stroke when compared to sham animal breathing consisted of a lower RR and autocorrelation, higher coefficient of variation for VT and higher coefficient of variation for Ve. Mutual information and the nonlinear complexity index were higher in breathing following stroke which also demonstrated a waxing/waning pattern. The absence of stroke in the sham animals was verified anatomically. We conclude that ventilatory pattern following cerebral infarction demonstrated increased variability with increased nonlinear patterning and a waxing/waning pattern, consistent with CSR. PMID:20472101
Evaluation of anthropometric parameters and physical fitness in elderly Japanese.
Miyatake, Nobuyuki; Miyachi, Motohiko; Tabata, Izumi; Numata, Takeyuki
2012-01-01
We evaluated anthropometric parameters and physical fitness in elderly Japanese. A total of 2,106 elderly Japanese (749 men and 1,357 women), aged 60-79 years, were enrolled in a cross-sectional investigation study. Anthropometric parameters and physical fitness, i.e., muscle strength and flexibility, were measured. Of the 2,106 subjects, 569 subjects (302 men and 267 women) were further evaluated for aerobic exercise level, using the ventilatory threshold (VT). Muscle strength in subjects in their 70s was significantly lower than that in subjects in their 60s in both sexes. Two hundred and twenty-nine men (30.6%) and 540 women (39.8%) were taking no medications. In men, anthropometric parameters were significantly lower and muscle strength, flexibility, and work rate at VT were significantly higher in subjects without medications than these values in subjects with medications. In women, body weight, body mass index (BMI), and abdominal circumference were significantly lower, and muscle strength was significantly higher in subjects without medications than these values in subjects with medications. This mean value may provide a useful database for evaluating anthropometric parameters and physical fitness in elderly Japanese subjects.
Couillard, Annabelle; Tremey, Emilie; Prefaut, Christian; Varray, Alain; Heraud, Nelly
2016-12-01
To determine and/or adjust exercise training intensity for patients when the cardiopulmonary exercise test is not accessible, the determination of dyspnoea threshold (defined as the onset of self-perceived breathing discomfort) during the 6-min walk test (6MWT) could be a good alternative. The aim of this study was to evaluate the feasibility and reproducibility of self-perceived dyspnoea threshold and to determine whether a useful equation to estimate ventilatory threshold from self-perceived dyspnoea threshold could be derived. A total of 82 patients were included and performed two 6MWTs, during which they raised a hand to signal self-perceived dyspnoea threshold. The reproducibility in terms of heart rate (HR) was analysed. On a subsample of patients (n=27), a stepwise regression analysis was carried out to obtain a predictive equation of HR at ventilatory threshold measured during a cardiopulmonary exercise test estimated from HR at self-perceived dyspnoea threshold, age and forced expiratory volume in 1 s. Overall, 80% of patients could identify self-perceived dyspnoea threshold during the 6MWT. Self-perceived dyspnoea threshold was reproducibly expressed in HR (coefficient of variation=2.8%). A stepwise regression analysis enabled estimation of HR at ventilatory threshold from HR at self-perceived dyspnoea threshold, age and forced expiratory volume in 1 s (adjusted r=0.79, r=0.63, and relative standard deviation=9.8 bpm). This study shows that a majority of patients with chronic obstructive pulmonary disease can identify a self-perceived dyspnoea threshold during the 6MWT. This HR at the dyspnoea threshold is highly reproducible and enable estimation of the HR at the ventilatory threshold.
Morán, Indalecio; Bellapart, Judith; Vari, Alessandra; Mancebo, Jordi
2006-04-01
To compare, in acute lung injury/acute respiratory distress syndrome (ALI/ARDS) patients, the short-term effects of heat and moisture exchangers (HME) and heated humidifiers (HH) on gas exchange, and also on respiratory system mechanics when isocapnic conditions are met. Prospective open clinical study. Intensive Care Service. Seventeen invasively ventilated ALI/ARDS patients. The study was performed in three phases: (1) determinations were made during basal ventilatory settings with HME; (2) basal ventilatory settings were maintained and HME was replaced by an HH; (3) using the same HH, tidal volume (Vt) was decreased until basal PaCO2 levels were reached. FiO2, respiratory rate and PEEP were kept unchanged. Respiratory mechanics, Vdphys, gas exchange and hemodynamic parameters were obtained at each phase. By using HH instead of HME and without changing Vt, PaCO2 decreased from 46+/-9 to 40+/-8 mmHg (p<0.001) and Vdphys decreased from 352+/-63 to 310+/-74 ml (p<0.001). Comparing the first phase with the third, Vt decreased from 521+/-106 to 440+/-118 ml (p<0.001) without significant changes in PaCO2, Vd/Vt decreased from 0.69+/-0.11 to 0.62+/-0.12 (p<0.001), plateau airway pressure decreased from 25+/-6 to 21+/-6 cmH2O (p<0.001) and respiratory system compliance improved from 35+/-12 to 42+/-15 ml/cmH2O (p<0.001). PaO2 remained unchanged in the three phases. Reducing dead space with the use of HH decreases PaCO2 and more importantly, if isocapnic conditions are maintained by reducing Vt, this strategy improves respiratory system compliance and reduces plateau airway pressure.
Lactate Threshold as a Measure of Aerobic Metabolism in Resistance Exercise.
Domínguez, Raúl; Maté-Muñoz, José Luis; Serra-Paya, Noemí; Garnacho-Castaño, Manuel Vicente
2018-02-01
In resistance training, load intensity is usually calculated as the percentage of a maximum repetition (1RM) or maximum number of possible repetitions (% of 1RM). Some studies have proposed a lactate threshold (LT) intensity as an optimal approach for concurrent training of cardiorespiratory endurance and muscle strength, as well as an alternative in resistance training. The objective of the present study was to analyze the results obtained in research evaluating the use of LT in resistance training. A keyword and search tree strategy identified 14 relevant articles in the Dialnet, Elsevier, Medline, Pubmed, Scopus and Web of Science databases. Based on the studies analyzed, the conclusion was that the LT in resistance exercises can be determined either by mathematical methods or by visual inspection of graphical plots. Another possibility is to measure the intensity at which LT might coincide with the first ventilatory threshold (VT1). Since performing an exercise session at one's LT intensity has been shown to accelerate the cardiorespiratory response and induce neuromuscular fatigue, this intensity could be used to set the training load in a resistance training program. © Georg Thieme Verlag KG Stuttgart · New York.
Durkalec-Michalski, Krzysztof; Jeszka, Jan
2016-09-01
Durkalec-Michalski, K and Jeszka, J. The effect of β-hydroxy-β-methylbutyrate on aerobic capacity and body composition in trained athletes. J Strength Cond Res 30(9): 2617-2626, 2016-The aim of this study was to investigate whether supplementation with β-hydroxy-β-methylbutyrate (HMB) affects body composition, aerobic capacity, or intramuscular enzymes activity, as well as in anabolic and/or catabolic hormones and lactate concentrations. A cohort of 58 highly trained males was subjected to 12-week supplementation with HMB (3 × 1 gHMB·d) and a placebo (PLA) in randomized, PLA controlled, double-blind crossover trials, with a 10-day washout period. Body composition and aerobic capacity were recorded, whereas the levels of creatine kinase, lactate dehydrogenase, testosterone, cortisol, and lactate, as well as the T/C ratio, in blood samples were measured. After HMB supplementation, fat-free mass increased (+0.2 kgHMB vs. -1.0 kgPLA, p = 0.021), with a simultaneous reduction of fat mass (-0.8 kgHMB vs. +0.8 kgPLA, p < 0.001). In turn, after HMB supplementation, in comparison to PLA, maximal oxygen uptake (V[Combining Dot Above][Combining Dot Above]O2max: +0.102 L·minHMB vs. -0.063 L·minPLA, p = 0.013), time to reach ventilatory threshold (VT) (TVT: +1.0 minHMB vs. -0.4 minPLA, p < 0.0001), threshold load at VT (WVT: +20 WHMB vs. -7 WPLA, p = 0.001), and the threshold heart rate at VT (HRVT: +8 b·minHMB vs. -1 b·minPLA, p < 0.0001) increased significantly. Analysis of the tested biochemical markers shows significant differences only in relation to the initial concentration. In HMB group, testosterone levels increased (p = 0.047) and in both groups (HMB: p = 0.008; PLA: p = 0.008) higher cortisol levels were observed. The results indicate that supplying HMB promotes advantageous changes in body composition and stimulates an increase in aerobic capacity, although seeming not to significantly affect the levels of the analyzed blood markers.
Jensen, Dennis; Webb, Katherine A; Davies, Gregory A L; O'Donnell, Denis E
2008-01-01
The aim of this study was to identify the physiological mechanisms of exertional respiratory discomfort (breathlessness) in pregnancy by comparing ventilatory (breathing pattern, airway function, operating lung volumes, oesophageal pressure (Poes)-derived indices of respiratory mechanics) and perceptual (breathlessness intensity) responses to incremental cycle exercise in 15 young, healthy women in the third trimester (TM3; between 34 and 38 weeks gestation) and again 4–5 months postpartum (PP). During pregnancy, resting inspiratory capacity (IC) increased (P < 0.01) and end-expiratory lung volume decreased (P < 0.001), with no associated change in total lung capacity (TLC) or static respiratory muscle strength. This permitted greater tidal volume (VT) expansion throughout exercise in TM3, while preserving the relationship between contractile respiratory muscle effort (tidal Poes swing expressed as a percentage of maximum inspiratory pressure (PImax)) and thoracic volume displacement (VT expressed as a percentage of vital capacity) and between breathlessness and ventilation (V̇E). At the highest equivalent work rate (HEWR = 128 ± 5 W) in TM3 compared with PP: V̇E, tidal Poes/PImax and breathlessness intensity ratings increased by 10.2 l min−1 (P < 0.001), 8.8%PImax (P < 0.05) and 0.9 Borg units (P < 0.05), respectively. Pulmonary resistance was not increased at rest or during exercise at the HEWR in TM3, despite marked increases in mean tidal inspiratory and expiratory flow rates, suggesting increased bronchodilatation. Dynamic mechanical constraints on VT expansion (P < 0.05) with associated increased breathlessness intensity ratings (P < 0.05) were observed near peak exercise in TM3 compared with PP. In conclusion: (1) pregnancy-induced increases in exertional breathlessness reflected the normal awareness of increased V̇E and contractile respiratory muscle effort; (2) mechanical adaptations of the respiratory system, including recruitment of resting IC and increased bronchodilatation, accommodated the increased VT while preserving effort–displacement and breathlessness–V̇E relationships; and (3) dynamic mechanical ventilatory constraints contributed to respiratory discomfort near the limits of tolerance in late gestation. PMID:18687714
Schaun, Gustavo Z; Pinto, Stephanie S; Silva, Mariana R; Dolinski, Davi B; Alberton, Cristine L
2018-05-07
Schaun, GZ, Pinto, SS, Silva, MR, Dolinski, DB, and Alberton, CL. Sixteen weeks of whole-body high-intensity interval training induce similar cardiorespiratory responses compared with traditional high-intensity interval training and moderate-intensity continuous training in healthy men. J Strength Cond Res XX(X): 000-000, 2018-Low-volume high-intensity interval training (HIIT) protocols that use the body weight as resistance could be an interesting and inexpensive alternative to traditional ergometer-based high-intensity interval training (HIIT-T) and moderate-intensity continuous training (MICT). Therefore, our aim was to compare the effects of 16 weeks of whole-body HIIT (HIIT-WB), HIIT-T, and MICT on maximal oxygen uptake (V[Combining Dot Above]O2max), second ventilatory threshold (VT2), and running economy (RE) outcomes. Fifty-five healthy men (23.7 ± 0.7 years, 1.79 ± 0.01 m, 78.5 ± 1.7 kg) were randomized into 3 training groups (HIIT-T = 17; HIIT-WB = 19; MICT = 19) for 16 weeks (3× per week). The HIIT-T group performed eight 20-second bouts at 130% of the velocity associated to V[Combining Dot Above]O2max (vV[Combining Dot Above]O2max) interspersed by 10-second passive recovery on a treadmill, whereas HIIT-WB group performed the same protocol but used calisthenics exercises at an all-out intensity instead of treadmill running. Finally, MICT group exercised for 30 minutes at 90-95% of the heart rate (HR) associated to VT2. After the intervention, all groups improved V[Combining Dot Above]O2max, vV[Combining Dot Above]O2max, time to exhaustion (Tmax), VT2, velocity associated with VT2 (vVT2), and time to reach VT2 (tVT2) significantly (p < 0.05). Moreover, Tmax, vVT2, and tVT2 were greater after HIIT-T compared with HIIT-WB (p < 0.05), whereas oxygen uptake increased and HR decreased during the RE test in all groups (p < 0.05). Our results demonstrate that HIIT-WB can be as effective as traditional HIIT while also being time-efficient compared with MICT to improve health-related outcomes after 16 weeks of training. However, HIIT-T and MICT seem preferable to enhance performance-related outcomes compared with HIIT-WB.
Fluoxetine augments ventilatory CO2 sensitivity in Brown Norway but not Sprague Dawley rats.
Hodges, Matthew R; Echert, Ashley E; Puissant, Madeleine M; Mouradian, Gary C
2013-04-01
The Brown Norway (BN; BN/NHsdMcwi) rat exhibits a deficit in ventilatory CO2 sensitivity and a modest serotonin (5-HT) deficiency. Here, we tested the hypothesis that the selective serotonin reuptake inhibitor fluoxetine would augment CO2 sensitivity in BN but not Sprague Dawley (SD) rats. Ventilation during room air or 7% CO2 exposure was measured before, during and after 3 weeks of daily injections of saline or fluoxetine (10mg/(kgday)) in adult male BN and SD rats. Fluoxetine had minimal effects on room air breathing in BN and SD rats (p>0.05), although tidal volume (VT) was reduced in BN rats (p<0.05). There were also minimal effects of fluoxetine on CO2 sensitivity in SD rats, but fluoxetine increased minute ventilation, breathing frequency and VT during hypercapnia in BN rats (p<0.05). The augmented CO2 response was reversible upon withdrawal of fluoxetine. Brain levels of biogenic amines were largely unaffected, but 5-HIAA and the ratio of 5-HIAA/5-HT were reduced (p<0.05) consistent with selective and effective 5-HT reuptake inhibition. Thus, fluoxetine increases ventilatory CO2 sensitivity in BN but not SD rats, further suggesting altered 5-HT system function may contribute to the inherently low CO2 sensitivity in the BN rat. Copyright © 2013 Elsevier B.V. All rights reserved.
Relationships Between Glycemic Control and Cardiovascular Fitness.
Moxley, Elizabeth W; Smith, Donald; Quinn, Lauretta; Park, Chang
2018-07-01
Diabetes is a serious health problem affecting approximately 29.1 million individuals in the United States. Another 86 million have prediabetes. The development and implementation of lifestyle modifications such as physical activity for these persons are among the most effective methods for prevention and treatment. The aim of this study was to examine relationships between glycemic control (HbA1c) and cardiovascular fitness (peak maximal oxygen uptake [VO 2 peak] and ventilatory threshold [VT]) in overweight/obese subjects with and without type 2 diabetes (T2DM). In addition, the influences of body mass index (BMI) and insulin sensitivity (homeostasis model assessment [HOMA %S]) on the relationship between glycemic control and cardiovascular fitness were explored. Data were abstracted from a completed study that included 51 overweight or obese subjects with T2DM ( n = 18), impaired glucose tolerance ( n = 8), or normal glucose tolerance ( n = 25). Relationships between glycemic control (HbA1c) and cardiovascular fitness (VO 2 peak and VT) were determined using correlational analysis and multiple linear regression analyses. A statistically significant relationship was observed between HbA1c and cardiovascular fitness. However, BMI and HOMA %S did not influence the relationship between glycemic control and cardiovascular fitness. HbA1c contributes to VO 2 peak and VT in obese and overweight subjects across glucose tolerance categories. Significant results were achieved despite the fact that there was a limited range of HbA1c based on the study inclusion criteria. This finding suggests that even a mild decrease in glycemic control can negatively influence cardiovascular fitness.
Forbes, Scott C; Sletten, Nathan; Durrer, Cody; Myette-Côté, Étienne; Candow, D; Little, Jonathan P
2017-06-01
High-intensity interval training (HIIT) has been shown to improve cardiorespiratory fitness, performance, body composition, and insulin sensitivity. Creatine (Cr) supplementation may augment responses to HIIT, leading to even greater physiological adaptations. The purpose of this study was to determine the effects of 4 weeks of HIIT (three sessions/week) combined with Cr supplementation in recreationally active females. Seventeen females (age = 23 ± 4 yrs; BMI = 23.4 ± 2.4) were randomly assigned to either Cr (Cr; 0.3 g・kg -1 ・d -1 for 5 d followed by 0.1 g・kg -1 ・d -1 for 23 days; n = 9) or placebo (PLA; n = 8). Before and after the intervention, VO 2peak , ventilatory threshold (VT), time-trial performance, lean body mass and fat mass, and insulin sensitivity were assessed. HIIT improved VO 2peak (Cr = +10.2%; PLA = +8.8%), VT (Cr = +12.7%; PLA = +9.9%), and time-trial performance (Cr = -11.5%; PLA = -11.6%) with no differences between groups (time main effects, all p < .001). There were no changes over time for fat mass (Cr = -0.3%; PLA = +4.3%), whole-body lean mass (Cr = +0.5%; PLA = -0.9%), or insulin resistance (Cr = +3.9%; PLA = +18.7%). In conclusion, HIIT is an effective way to improve cardiorespiratory fitness, VT, and time-trial performance. The addition of Cr to HIIT did not augment improvements in cardiorespiratory fitness, performance or body composition in recreationally active females.
Mendonca, Goncalo V; Teixeira, Micael S; Heffernan, Kevin S; Fernhall, Bo
2013-06-01
Ingestion of water attenuates the chronotropic response to submaximal exercise. However, it is not known whether this effect is equally manifested during dynamic exercise below and above the ventilatory threshold (VT). We explored the effects of water ingestion on the heart rate response to an incremental cycle-ergometer protocol. In a randomized fashion, 19 healthy adults (10 men and nine women, age 20.9 ± 1.8 years) ingested 50 and 500 ml of water before completing a cycle-ergometer protocol on two separate days. The heart rate and oxygen uptake ( ) responses to water ingestion were analysed both at rest and during exercise performed below and above the VT. The effects of water intake on brachial blood pressure were measured only at rest. Resting mean arterial pressure increased and resting heart rate decreased, but only after 500 ml of water (P < 0.05). Compared with that seen after 50 ml of water, the 500 ml volume elicited an overall decrease in submaximal heart rate (P < 0.05). In contrast, drinking 500 ml of water did not affect submaximal . The participants' maximal heart rate, maximal and VT were similar between conditions. Our results therefore indicate that, owing to its effects on submaximal heart rate over a broad spectrum of intensities, the drinking of water should be recognized as a potential confounder in cardiovascular exercise studies. However, by showing no differences between conditions for submaximal , they also suggest that the magnitude of heart rate reduction after drinking 500 ml of water may be of minimal physiological significance for exercise cardiorespiratory capacity.
Chao, T.P.; Sperandio, E.F.; Ostolin, T.L.V.P.; Almeida, V.R.; Romiti, M.; Gagliardi, A.R.T.; Arantes, R.L.; Dourado, V.Z.
2018-01-01
Spirometry has been used as the main strategy for assessing ventilatory changes related to occupational exposure to particulate matter (OEPM). However, in some cases, as one of its limitations, it may not be sensitive enough to show abnormalities before extensive damage, as seen in restrictive lung diseases. Therefore, we hypothesized that cardiopulmonary exercise testing (CPET) may be better than spirometry to detect early ventilatory impairment caused by OEPM. We selected 135 male workers with at least one year of exposure. After collection of self-reported socioeconomic status, educational level, and cardiovascular risk data, participants underwent spirometry, CPET, body composition assessment (bioelectrical impedance), and triaxial accelerometry (for level of physical activity in daily life). CPET was performed using a ramp protocol on a treadmill. Metabolic, cardiovascular, ventilatory, and submaximal relationships were measured. We compared 52 exposed to 83 non-exposed workers. Multiple linear regressions were developed using spirometry and CPET variables as outcomes and OEPM as the main predictor, and adjusted by the main covariates. Our results showed that OEPM was associated with significant reductions in peak minute ventilation, peak tidal volume, and breathing reserve index. Exposed participants presented shallower slope of ΔVT/ΔlnV̇E (breathing pattern), i.e., increased tachypneic breathing pattern. The OEPM explained 7.4% of the ΔVT/ΔlnV̇E variability. We found no significant influence of spirometric indices after multiple linear regressions. We conclude that CPET might be a more sensitive feature of assessing early pulmonary impairment related to OEPM. Our cross-sectional results suggested that CPET is a promising tool for the screening of asymptomatic male workers. PMID:29590255
Park, Sung Wook; Brenneman, Michael; Cooke, William H; Cordova, Alberto; Fogt, Donovan
The purpose was to determine if heart rate (HR) and heart rate variability (HRV) responses would reflect anaerobic threshold (AT) using a discontinuous, incremental, cycle test. AT was determined by ventilatory threshold (VT). Cyclists (30.6±5.9y; 7 males, 8 females) completed a discontinuous cycle test consisting of 7 stages (6 min each with 3 min of rest between). Three stages were performed at power outputs (W) below those corresponding to a previously established AT, one at W corresponding to AT, and 3 at W above those corresponding to AT. The W at the intersection of the trend lines was considered each metric's "threshold". The averaged stage data for Ve, HR, and time- and frequency-domain HRV metrics were plotted versus W. The W at the "threshold" for the metrics of interest were compared using correlation analysis and paired-sample t -test. In all, several heart rate-related parameters accurately reflected AT with significant correlations (p≤0.05) were observed between AT W and HR, mean RR interval (MRR), low and high frequency spectral energy (LF and HR, respectively), high frequency peak (fHF), and HFxfHF metrics' threshold W (i.e., MRRTW, etc.). Differences in HR or HRV metric threshold W and AT for all subjects were less than 14 W. The steady state data from discontinuous protocols may allow for a true indication of steady-state physiologic stress responses and corresponding W at AT, compared to continuous protocols using 1-2 min exercise stages.
Postural control after a prolonged treadmill run at individual ventilatory and anaerobic threshold.
Guidetti, Laura; Franciosi, Emanuele; Gallotta, Maria Chiara; Emerenziani, Gian Pietro; Baldari, Carlo
2011-01-01
The objective of the study was to verify whether young males' balance was affected by 30min prolonged treadmill running (TR) at individual ventilatory (IVT) and anaerobic (IAT) thresholds in recovery time. The VO2max, IAT and IVT during an incremental TR were determined. Mean displacement amplitude (Acp) and velocity (Vcp) of center of pressure were recorded before (pre) and after (0min post; 5min post; and 10min post) prolonged TR at IAT and IVT, through posturographic trials performed with eyes open (EO) and closed (EC). Significant differences between IVT and IAT for Vcp, between EO and EC for Acp and Vcp, were observed. The IAT induced higher destabilizing effect when postural trials were performed with EC. The IVT intensity produced also a destabilizing effect on postural control immediately after exercise. An impairment of postural control after prolonged treadmill running exercise at IVT and IAT intensity was showed. However, destabilizing effect on postural control disappeared within 10min after IAT intensity and within 5min after IVT intensity. Key pointsTo verify whether young males' balance was affected by 30min prolonged treadmill running at individual ventilatory and anaerobic thresholds in recovery time.Mean displacement amplitude and velocity of foot pressure center were recorded before and after prolonged treadmill running at individual ventilatory and anaerobic thresholds, through posturographic trials performed with eyes open and closed.Destabilizing effect on postural control disappeared within 10min post individual anaerobic threshold, and within 5min post individual ventilatory threshold.
Bonnevie, Tristan; Gravier, Francis-Edouard; Leboullenger, Marie; Médrinal, Clément; Viacroze, Catherine; Cuvelier, Antoine; Muir, Jean-François; Tardif, Catherine; Debeaumont, David
2017-06-01
Pulmonary rehabilitation (PR) improves outcomes in patients with chronic obstructive pulmonary disease (COPD). Optimal assessment includes cardiopulmonary exercise testing (CPET), but consultations are limited. Field tests could be used to individualize PR instead of CPET. The six-minute stepper test (6MST) is easy to set up and its sensitivity and reproducibility have previously been reported in patients with COPD. The aim of this study was to develop a prediction equation to set intensity in patients attending PR, based on the 6MST. The following relationships were analyzed: mean heart rate (HR) during the first (HR 1-3 ) and last (HR 4-6 ) 3 minutes of the 6MST and HR at the ventilatory threshold (HRvt) from CPET; step count at the end of the 6MST and workload at the Ventilatory threshold (VT) (Wvt); and forced expiratory volume in 1 second and step count during the 6MST. This retrospective study included patients with COPD referred for PR who underwent CPET, pulmonary function evaluations and the 6MST. Twenty-four patients were included. Prediction equations were HRvt = 0.7887 × HR 1-3 + 20.83 and HRvt = 0.6180 × HR 4-6 + 30.77. There was a strong correlation between HR 1-3 and HR 4-6 and HRvt (r = 0.69, p < 0.001 and r = 0.57, p < 0.01 respectively). A significant correlation was also found between step count and LogWvt (r = 0.63, p < 0.01). The prediction equation was LogWvt = 0.001722 × step count + 1.248. The 6MST could be used to individualize aerobic training in patients with COPD. Further prospective studies are needed to confirm these results.
Silva, Talita M; Aranda, Liliane C; Paula-Ribeiro, Marcelle; Oliveira, Diogo M; Medeiros, Wladimir Musetti; Vianna, Lauro C; Nery, Luiz E; Silva, Bruno M
2018-03-22
Physical exercise potentiates the carotid chemoreflex control of ventilation (VE). Hyperadditive neural interactions may partially mediate the potentiation. However, some neural interactions remain incompletely explored. As the potentiation occurs even during low-intensity exercise, we tested the hypothesis that the carotid chemoreflex and the muscle mechanoreflex could interact in a hyperadditive fashion. Fourteen young healthy subjects inhaled, randomly, in separate visits, 12% O 2 to stimulate the carotid chemoreflex, and 21% O 2 as control. A rebreathing circuit maintained isocapnia. During gases administration, subjects either remained at rest (i.e., normoxic and hypoxic rest) or the muscle mechanoreflex was stimulated, via passive knee movement (i.e., normoxic and hypoxic movement). Surface muscle electrical activity did not increase during the passive movement, confirming the absence of active contractions. Hypoxic rest and normoxic movement similarly increased VE [change (mean {plus minus} SEM) = 1.24 {plus minus} 0.72 vs. 0.73 {plus minus} 0.43 L/min, respectively; P = 0.46], but hypoxic rest only increased tidal volume (Vt) and normoxic movement only increased breathing frequency (BF). Hypoxic movement induced greater VE and mean inspiratory flow (Vt/Ti) increase than the sum of hypoxic rest and normoxic movement isolated responses (VE change: hypoxic movement = 3.72 {plus minus} 0.81 vs. sum = 1.96 {plus minus} 0.83 L/min, P = 0.01; Vt/Ti change: hypoxic movement = 0.13 {plus minus} 0.03 vs. sum = 0.06 {plus minus} 0.03 L/s, P = 0.02). Moreover, hypoxic movement increased both Vt and BF. Collectively, the results indicate the carotid chemoreflex and the muscle mechanoreflex interacted mediating a hyperadditive ventilatory response in healthy humans.
Robinson, Edward H; Stout, Jeffrey R; Miramonti, Amelia A; Fukuda, David H; Wang, Ran; Townsend, Jeremy R; Mangine, Gerald T; Fragala, Maren S; Hoffman, Jay R
2014-01-01
Previous research combining Calcium β-hydroxy-β-methylbutyrate (CaHMB) and running high-intensity interval training (HIIT) have shown positive effects on aerobic performance measures. The purpose of this study was to examine the effect of β-hydroxy-β-methylbutyric free acid (HMBFA) and cycle ergometry HIIT on maximal oxygen consumption (VO2peak), ventilatory threshold (VT), respiratory compensation point (RCP) and time to exhaustion (Tmax) in college-aged men and women. Thirty-four healthy men and women (Age: 22.7 ± 3.1 yrs ; VO2peak: 39.3 ± 5.0 ml · kg(-1) · min(-1)) volunteered to participate in this double-blind, placebo-controlled design study. All participants completed a series of tests prior to and following treatment. A peak oxygen consumption test was performed on a cycle ergometer to assess VO2peak, Tmax, VT, and RCP. Twenty-six participants were randomly assigned into either a placebo (PLA-HIIT) or 3 g per day of HMBFA (BetaTor™) (HMBFA-HIIT) group. Eight participants served as controls (CTL). Participants in the HIIT groups completed 12 HIIT (80-120% maximal workload) exercise sessions consisting of 5-6 bouts of a 2:1 minute cycling work to rest ratio protocol over a four-week period. Body composition was measured with dual energy x-ray absorptiometry (DEXA). Outcomes were assessed by ANCOVA with posttest means adjusted for pretest differences. The HMBFA-HIIT intervention showed significant (p < 0.05) gains in VO2peak, and VT, versus the CTL and PLA-HIIT group. Both PLA-HIIT and HMBFA-HIIT treatment groups demonstrated significant (p < 0.05) improvement over CTL for Tmax, and RCP with no significant difference between the treatment groups. There were no significant differences observed for any measures of body composition. An independent-samples t-test confirmed that there were no significant differences between the training volumes for the PLA-HIIT and HMBFA-HIIT groups. Our findings support the use of HIIT in combination with HMBFA to improve aerobic fitness in college age men and women. These data suggest that the addition of HMBFA supplementation may result in greater changes in VO2peak and VT than HIIT alone. The study was registered on ClinicalTrials.gov (ID NCT01941368).
McAuliffe, Liam; Parfitt, Gaynor C; Eston, Roger G; Gray, Caitlin; Keage, Hannah A D; Smith, Ashleigh E
2018-01-01
Exercise adherence in already low-active older adults with and without mild cognitive impairment (MCI) remains low. Perceptual regulation and exergaming may facilitate future exercise behaviour by improving the affective experience, however evidence that this population can perceptually regulate is lacking. To explore this, we investigated 1) perceptual regulation of exercise intensity during either exergaming or regular ergometer cycling and 2) explored affective responses. Thirty-two low active older adults (73.9 ± 7.3 years, n = 16, 8 females) with or without MCI (70.9 ± 5.5 years, n = 16, 11 females) participated in a sub-maximal fitness assessment to determine ventilatory threshold (VT) and two experimental sessions (counterbalanced: exergaming or regular ergometer cycling). Experimental sessions consisted 21-min of continuous cycling with 7-min at each: RPE 9, 11 and 13. Oxygen consumption (VO 2 ), heart rate (HR), and affect (Feeling Scale) were obtained throughout the exercise. VO 2 ( p < 0.01) and HR ( p < 0.01) increased linearly with RPE, but were not significantly different between exercise modes or cognitive groups. At RPE 13, participants worked above VT in both modes (exergaming: 115.7 ± 27.3; non-exergaming 114.1 ± 24.3 VO 2 (%VT)). Regardless of cognitive group, affect declined significantly as RPE increased ( p < 0.01). However on average, affect remained pleasant throughout and did not differ between exercise modes or cognitive groups. These results suggest low-active older adults can perceptually regulate exercise intensity, regardless of cognition or mode. At RPE 13, participants regulated above VT, at an intensity that improves cardiorespiratory fitness long-term, and affect remained positive in the majority of participants, which may support long-term physical activity adherence.
Belão, T C; Zeraik, V M; Florindo, L H; Kalinin, A L; Leite, C A C; Rantin, F T
2015-09-01
We evaluated the role of the first pair of gill arches in the control of cardiorespiratory responses to normoxia and hypoxia in the air-breathing catfish, Clarias gariepinus. An intact group (IG) and an experimental group (EG, bilateral excision of first gill arch) were submitted to graded hypoxia, with and without access to air. The first pair of gill arches ablations reduced respiratory surface area and removed innervation by cranial nerve IX. In graded hypoxia without access to air, both groups displayed bradycardia and increased ventilatory stroke volume (VT), and the IG showed a significant increase in breathing frequency (fR). The EG exhibited very high fR in normoxia that did not increase further in hypoxia, this was linked to reduced O2 extraction from the ventilatory current (EO2) and a significantly higher critical O2 tension (PcO2) than the IG. In hypoxia with access to air, only the IG showed increased air-breathing, indicating that the first pair of gill arches excision severely attenuated air-breathing responses. Both groups exhibited bradycardia before and tachycardia after air-breaths. The fH and gill ventilation amplitude (VAMP) in the EG were overall higher than the IG. External and internal NaCN injections revealed that O2 chemoreceptors mediating ventilatory hypoxic responses (fR and VT) are internally oriented. The NaCN injections indicated that fR responses were mediated by receptors predominantly in the first pair of gill arches but VT responses by receptors on all gill arches. Receptors eliciting cardiac responses were both internally and externally oriented and distributed on all gill arches or extra-branchially. Air-breathing responses were predominantly mediated by receptors in the first pair of gill arches. In conclusion, the role of the first pair of gill arches is related to: (a) an elevated EO2 providing an adequate O2 uptake to maintain the aerobic metabolism during normoxia; (b) a significant bradycardia and increased fAB elicited by externally oriented O2 chemoreceptors; (c) increase in the ventilatory variables (fR and VAMP) stimulated by internally oriented O2 chemoreceptors. Copyright © 2015 Elsevier Inc. All rights reserved.
Gómez-Molina, Josué; Ogueta-Alday, Ana; Camara, Jesus; Stickley, Christopher; García-López, Juan
2018-03-01
Concurrent plyometric and running training has the potential to improve running economy (RE) and performance through increasing muscle strength and power, but the possible effect on spatiotemporal parameters of running has not been studied yet. The aim of this study was to compare the effect of 8 weeks of concurrent plyometric and running training on spatiotemporal parameters and physiological variables of novice runners. Twenty-five male participants were randomly assigned into two training groups; running group (RG) (n = 11) and running + plyometric group (RPG) (n = 14). Both groups performed 8 weeks of running training programme, and only the RPG performed a concurrent plyometric training programme (two sessions per week). Anthropometric, physiological (VO 2max , heart rate and RE) and spatiotemporal variables (contact and flight times, step rate and length) were registered before and after the intervention. In comparison to RG, the RPG reduced step rate and increased flight times at the same running speeds (P < .05) while contact times remained constant. Significant increases in pre- and post-training (P < .05) were found in RPG for squat jump and 5 bound test, while RG remained unchanged. Peak speed, ventilatory threshold (VT) speed and respiratory compensation threshold (RCT) speed increased (P < .05) for both groups, although peak speed and VO 2max increased more in the RPG than in the RG. In conclusion, concurrent plyometric and running training entails a reduction in step rate, as well as increases in VT speed, RCT speed, peak speed and VO 2max . Athletes could benefit from plyometric training in order to improve their strength, which would contribute to them attaining higher running speeds.
Impact of beta-blockers on cardiopulmonary exercise testing in patients with advanced liver disease.
Wallen, M P; Hall, A; Dias, K A; Ramos, J S; Keating, S E; Woodward, A J; Skinner, T L; Macdonald, G A; Arena, R; Coombes, J S
2017-10-01
Patients with advanced liver disease may develop portal hypertension that can result in variceal haemorrhage. Beta-blockers reduce portal pressure and minimise haemorrhage risk. These medications may attenuate measures of cardiopulmonary performance, such as the ventilatory threshold and peak oxygen uptake measured via cardiopulmonary exercise testing. To determine the effect of beta-blockers on cardiopulmonary exercise testing variables in patients with advanced liver disease. This was a cross-sectional analysis of 72 participants who completed a cardiopulmonary exercise test before liver transplantation. All participants remained on their usual beta-blocker dose and timing prior to the test. Variables measured during cardiopulmonary exercise testing included the ventilatory threshold, peak oxygen uptake, heart rate, oxygen pulse, the oxygen uptake efficiency slope and the ventilatory equivalents for carbon dioxide slope. Participants taking beta-blockers (n = 28) had a lower ventilatory threshold (P <.01) and peak oxygen uptake (P = .02), compared to participants not taking beta-blockers. After adjusting for age, the model of end-stage liver-disease score, liver-disease aetiology, presence of refractory ascites and ventilatory threshold remained significantly lower in the beta-blocker group (P = .04). The oxygen uptake efficiency slope was not impacted by beta-blocker use. Ventilatory threshold is reduced in patients with advanced liver disease taking beta-blockers compared to those not taking the medication. This may incorrectly risk stratify patients on beta-blockers and has implications for patient management before and after liver transplantation. The oxygen uptake efficiency slope was not influenced by beta-blockers and may therefore be a better measure of cardiopulmonary performance in this patient population. © 2017 John Wiley & Sons Ltd.
Vogel, T; Leprêtre, P-M; Brechat, P-H; Lonsdorfer, E; Benetos, A; Kaltenbach, G; Lonsdorfer, J
2011-12-01
The aim of this study was to evaluate the efficiency of a short-term Intermittent Work Exercise Program (IWEP) among healthy elderly subjects. This longitudinal prospective study took place at the Strasbourg University Hospital geriatric department. One hundred and fifty older volunteers, previously determined as being free from cardiac and pulmonary disease, were separated into two age groups: the "young senior" (60.2 ± 3.1 yr) and the "older senior" groups (70.8 ± 5.2 yr). These groups were then subdivided by gender into the "young female senior", "young male senior" "older female senior" and "older male senior" groups. Before and after the IWEP, all subjects were asked to perform an incremental cycle exercise to obtain their first ventilatory threshold (VT1), maximal tolerated power (MTP), peak oxygen uptake (VO2peak) and maximal minute ventilation (MMV). The IWEP consisted of a 30-min cycling exercise which took place twice a week, and was divided into six 5-min stages consisting of 4 min at VT1 intensity and 1 min at 90% MTP. An assessment was made of the effects of the IWEP on maximal cardio-respiratory function (MTP, VO2peak, MMV) and endurance parameters (VT1, heart rate [HR] measured at pretraining VT1 and lactate concentrations at pre-training MTP). This short-term training program resulted in a significant increase of MTP (from 13.2% to 20.6%), VO2peak (from 8.9% to 16.6%) and MMV (from 11.1% to 21.8%) in all groups (p<0.05). VT1 improved from 21% at pretraining to 27%, while HR at pre-training VT1 as well as lactate concentrations at pre-training MTP decreased significantly in all groups (p<0.05). The post-training values for VO2peak and MMV of the "older seniors" were not significantly different (p>0.05) from the "young seniors" pre-training values for the same parameters. The most striking finding in this study is that after only 9 weeks, our short-term "individually-tailored" IWEP significantly improved both maximal cardio-respiratory function and endurance parameters in healthy, previously untrained seniors.
Effects of Reduced Strength on Self-Selected Pacing for Long-Duration Activities
NASA Technical Reports Server (NTRS)
Buxton, Roxanne E.; Ryder, Jeffrey W.; English, Kirk E.; Guined, Jamie R.; Ploutz-Snyder, Lori L.
2015-01-01
Strength and aerobic capacity are predictors of astronaut performance for extravehicular activities (EVA) during exploration missions. It is expected that astronauts will self-select a pace below their ventilatory threshold (VT). PURPOSE: To determine the percentage of VT that subjects self-select for prolonged occupational tasks. METHODS: Maximal aerobic capacity and a variety of lower-body strength and power variables were assessed in 17 subjects who climbed 480 rungs on a ladder ergometer and then completed 10 km on a treadmill as quickly as possible using a self-selected pace. The tasks were performed on 4 days, with a weighted suit providing 0% (suit fabric only), 40%, 60%, and 80% of additional bodyweight (BW), thereby altering the strength to BW ratio. Oxygen consumption and heart rate were continuously measured. Repeated measures ANOVA and post-hoc comparisons were performed on the percent of VT values under each suited condition. RESULTS: Subjects consistently self-paced at or below VT for both tasks and the pace was related to suit weight. At the midpoint for the ladder climb the 80% BW condition elicited the lowest metabolic cost (-19+/-14% below VT), significantly different than the 0% BW (-3+/-16%, P=0.002) and the 40% BW conditions (-5+/-22%, P=0.023). The 60% BW condition (-13+/-19%) was different than the 40% BW condition (P=0.034). Upon completion of the ladder task there were no differences among the conditions (0%BW: 3+/-18%; 40%BW: 3+/-21%; 60%BW: - 8+/-25%; 80%BW: -10+/-18%). All subjects failed to complete 5km at 80%BW. At the midpoint of the treadmill test the three remaining conditions were all significantly different (0%BW: -20+/-15%; 40%BW: - 33+/-15%; 60%BW: -41+/-19%). Upon completion of the treadmill test the 60% BW condition (-38+/-12%) was significantly different than the 40% BW (-28+/-15%, P=0.024). CONCLUSIONS: Decreasing relative strength results in progressive and disproportionate decreases (relative to VT) in self-selected pacing during long-duration activities. Thus, during prolonged, endurance-type activities, large reductions in strength cause notable performance decrements despite no changes in aerobic capacity. These data highlight the importance of both aerobic capacity and muscle strength to the performance of prolonged EVA in exploration mission scenarios.
Lockwood, Christopher M; Moon, Jordan R; Smith, Abbie E; Tobkin, Sarah E; Kendall, Kristina L; Graef, Jennifer L; Cramer, Joel T; Stout, Jeffrey R
2010-08-01
Energy drink use has grown despite limited research to support efficacy or safety and amid concerns when combined with exercise. The purpose of this study was to assess the effects of 10 weeks of once-daily energy drink consumption or energy drink consumption with exercise on measures of body composition, cardiorespiratory fitness, strength, mood, and safety in previously sedentary males. Thirty-eight males were randomly assigned to energy drink + exercise (EX-A), energy drink (NEX-A), placebo + exercise (EX-B), or placebo (NEX-B). All participants consumed 1 drink per day for 10 weeks; EX-A and EX-B participated in 10 weeks of resistance and endurance exercise. Testing was performed before (PRE) and after (POST) the 10-week intervention. No significant (p > 0.05) changes were observed for body composition, fitness, or strength in NEX-A; however, significantly greater decreases in fat mass and percentage body fat and increases in VO2peak were observed in EX-A versus EX-B. Ventilatory threshold (VT), minute ventilation, VO2 at VT, and power output at VT improved significantly PRE to POST in EX-A but not in EX-B or nonexercising groups. Clinical markers for hepatic, renal, cardiovascular, and immune function, as determined by PRE and POST blood work revealed no adverse effects in response to the energy drink. Mood was not affected by energy drink use. Absent energy restriction or other dietary controls, chronic ingestion of a once-daily low-calorie energy drink appears ineffective at improving body composition, cardiorespiratory fitness, or strength in sedentary males. However, when combined with exercise, preworkout energy drink consumption may significantly improve some physiological adaptations to combined aerobic and resistance training.
Prado, Wagner L; Balagopal, P Babu; Lofrano-Prado, Mara C; Oyama, Lila M; Tenório, Thiago Ricardo; Botero, João Paulo; Hill, James O
2014-11-01
Exercise is implicated in modifying subsequent energy intake (EI) through alterations in hunger and/or satiety hormones. Our aim was to examine the effects of aerobic exercise on hunger, satiety regulatory peptides, and EI in obese adolescents. Nine obese girls (age: 13-18 years old, BMI: 33.74 ± 4.04 kg/m2) participated in this randomized controlled crossover study. Each participant randomly underwent 2 experimental protocols: control (seated for 150 min) and exercise (exercised for 30 min on a treadmill performed at ventilatory threshold [VT] intensity and then remained seated for 120 min). Leptin, peptide YY(3-36) (PYY(3-36)), and subjective hunger were measured at baseline as well as 30 min and 150 min, followed by 24-hr EI measurement. Exercise session resulted in an acute increase in PYY(3-36) (p < .01) without changes in leptin and/or hunger scores. The control session increased hunger scores (p < .01) and decreased circulating leptin levels (p = .03). There was a strong effect size for carbohydrate intake (d = 2.14) and a modest effect size for protein intake (d = 0.61) after the exercise compared with the control session. Exercise performed at VT intensity in this study appears to provoke a state of transient anorexia in obese girls. These changes may be linked to an increase in circulating PYY3-36 and maintenance of leptin levels.
Validation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities.
Villar, Rodrigo; Beltrame, Thomas; Hughson, Richard L
2015-10-01
We tested the validity of the Hexoskin wearable vest to monitor heart rate (HR), breathing rate (BR), tidal volume (VT), minute ventilation, and hip motion intensity (HMI) in comparison with laboratory standard devices during lying, sitting, standing, and walking. Twenty healthy young volunteers participated in this study. First, participants walked 6 min on a treadmill at speeds of 1, 3, and 4.5 km/h followed by increasing treadmill grades until 80% of their predicted maximal heart rate. Second, lying, sitting, and standing tasks were performed (5 min each) followed by 6 min of treadmill walking at 80% of their ventilatory threshold. Analysis of each individual's mean values under each resting or exercise condition by the 2 measurement systems revealed low coefficient of variation and high intraclass correlation values for HR, BR, and HMI. The Bland-Altman results from HR, BR, and HMI indicated no deviation of the mean value from zero and relatively small variability about the mean. VT and minute ventilation were provided in arbitrary units by the Hexoskin device; however, relative magnitude of change from Hexoskin closely tracked the laboratory standard method. Hexoskin presented low variability, good agreement, and consistency. The Hexoskin wearable vest was a valid and consistent tool to monitor activities typical of daily living such as different body positions (lying, sitting, and standing) and various walking speeds.
Running economy and body composition between competitive and recreational level distance runners.
Mooses, Martin; Jürimäe, J; Mäestu, J; Mooses, K; Purge, P; Jürimäe, T
2013-09-01
The aim of the present study was to compare running economy between competitive and recreational level athletes at their individual ventilatory thresholds on track and to compare body composition parameters that are related to the individual running economy measured on track. We performed a cross-sectional analysis of a total 45 male runners classified as competitive runners (CR; n = 28) and recreational runners (RR; n = 17). All runners performed an incremental test on treadmill until voluntary exhaustion and at least 48 h later a 2 × 2000 m test at indoor track with intensities according to ventilatory threshold 1, ventilator threshold 2. During the running tests, athletes wore portable oxygen analyzer. Body composition was measured with Dual energy X-ray absorptiometry (DXA) method. Running economy at the first ventilatory threshold was not significantly related to any of the measured body composition values or leg mass ratios either in the competitive or in the recreational runners group. This study showed that there was no difference in the running economy between distance runners with different performance level when running on track, while there was a difference in the second ventilatory threshold speed in different groups of distance runners. Differences in running economy between competitive and recreational athletes cannot be explained by body composition and/or different leg mass ratios.
Luo, Jian-yu; Wang, Xiao-yuan; Cai, Tian-bin; Jiang, Wen-fang
2013-02-01
To investigate the setting of ventilator volume tidal (VT) and airway pressure alarm threshold during cardiopulmonary resuscitation (CPR) by continuous extra-sternum heart compression. Forty cases with respiration and cardiac arrest in the department of critical care medicine were randomly divided into low VT ventilation group and conventional VT group. Both groups were given the volume control mode. In the low VT ventilation group, VT was set on 6 - 7 ml/kg, and high pressure alarm threshold was adjusted to 60 cm H2O by the conventional 40 cm H2O during CPR. In the conventional VT group, VT and high pressure alarm threshold were set at 8 - 12 ml/kg and 40 cm H2O, respectively. Real-time actual VT, peak inspiratory pressure (PIP), and arterial blood gas test, blood lactic acid at 10 minutes and 30 minutes after CPR were observed. At 10 minutes after CPR, in the low VT ventilation group, arterial blood pH, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2), HCO3(-), arterial oxygen saturation (SaO2) and blood lactic acid were better as compared with those in the conventional VT ventilation group (pH: 7.21±0.09 vs. 7.13±0.07, PaO2: 45.35±5.92 mm Hg vs. 40.70±4.70 mm Hg, PaCO2: 57.10±7.59 mm Hg vs. 61.60±5.47 mm Hg, HCO3(-): 18.50±3.50 mmol/L vs. 14.75±2.65 mmol/L, SaO2: 0.796±0.069 vs. 0.699±0.066, blood lactic acid: 7.07±1.60 mmol/L vs. 8.13±1.56 mmol/L, all P<0.05). The success rate of resuscitation in the low VT ventilation group was higher than that of the conventional VT ventilation group (45% vs. 15%, P<0.05), and PIP (cm H2O) of low VT ventilation group was lower than that of the conventional VT group (37.25±7.99 cm H2O vs. 42.70±7.40 cm H2O, P<0.05). In all the patients in both groups barotrauma did not occur. The strategy of low ventilator VT (6 - 7 ml/kg) with appropriate elevation of airway pressure alarm threshold was better than that of conventional ventilation setting, with no increase in incidence of barotraumas during CPR.
Pulmonary rehabilitation improves cardiovascular response to exercise in COPD.
Ramponi, Sara; Tzani, Panagiota; Aiello, Marina; Marangio, Emilio; Clini, Enrico; Chetta, Alfredo
2013-01-01
Pulmonary rehabilitation (PR) has emerged as a recommended standard of care in symptomatic COPD. We now studied whether PR may affect cardiovascular response to exercise in these patients. Twenty-seven patients (9 females aged 69 ± 8 years) with moderate-to-severe airflow obstruction admitted to a 9-week PR course performed a pre-to-post evaluation of lung function test and symptom-limited cardiopulmonary exercise test (CPET). Oxygen uptake (VO2), tidal volume (V(T)), dyspnea and leg fatigue scores were measured during CPET. Cardiovas-cular response was assessed by means of oxygen pulse (O2Pulse), the oxygen uptake efficiency slope and heart rate recovery at the 1st min. A significant increase in peak VO2 and in all cardiovascular parameters (p < 0.05) was found following PR when compared to baseline. Leg fatigue (p < 0.05), but not dyspnea, was significantly reduced after PR. When assessed at metabolic and ventilatory iso levels [% VCO2max and % minute ventilation (VEmax)], O2Pulse and V(T) were significantly higher (p < 0.05) at submaximal exercise (75 and 50% of VCO2max and VEmax) after PR when compared to baseline. V(T) percent changes at 75% VCO2max and 75% VEmax after PR significantly correlated with corresponding changes in O2Pulse (p < 0.01). In COPD patients, a PR training program improved the cardiovascular response during exercise at submaximal exercise independent of the external workload. This change was associated with an enhanced ventilatory function during exercise. Copyright © 2013 S. Karger AG, Basel.
2014-01-01
Background Previous research combining Calcium β-hydroxy-β-methylbutyrate (CaHMB) and running high-intensity interval training (HIIT) have shown positive effects on aerobic performance measures. The purpose of this study was to examine the effect of β-hydroxy-β-methylbutyric free acid (HMBFA) and cycle ergometry HIIT on maximal oxygen consumption (VO2peak), ventilatory threshold (VT), respiratory compensation point (RCP) and time to exhaustion (Tmax) in college-aged men and women. Methods Thirty-four healthy men and women (Age: 22.7 ± 3.1 yrs ; VO2peak: 39.3 ± 5.0 ml · kg-1 · min-1) volunteered to participate in this double-blind, placebo-controlled design study. All participants completed a series of tests prior to and following treatment. A peak oxygen consumption test was performed on a cycle ergometer to assess VO2peak, Tmax, VT, and RCP. Twenty-six participants were randomly assigned into either a placebo (PLA-HIIT) or 3 g per day of HMBFA (BetaTor™) (HMBFA-HIIT) group. Eight participants served as controls (CTL). Participants in the HIIT groups completed 12 HIIT (80-120% maximal workload) exercise sessions consisting of 5–6 bouts of a 2:1 minute cycling work to rest ratio protocol over a four-week period. Body composition was measured with dual energy x-ray absorptiometry (DEXA). Outcomes were assessed by ANCOVA with posttest means adjusted for pretest differences. Results The HMBFA-HIIT intervention showed significant (p < 0.05) gains in VO2peak, and VT, versus the CTL and PLA-HIIT group. Both PLA-HIIT and HMBFA-HIIT treatment groups demonstrated significant (p < 0.05) improvement over CTL for Tmax, and RCP with no significant difference between the treatment groups. There were no significant differences observed for any measures of body composition. An independent-samples t-test confirmed that there were no significant differences between the training volumes for the PLA-HIIT and HMBFA-HIIT groups. Conclusions Our findings support the use of HIIT in combination with HMBFA to improve aerobic fitness in college age men and women. These data suggest that the addition of HMBFA supplementation may result in greater changes in VO2peak and VT than HIIT alone. Study registration The study was registered on ClinicalTrials.gov (ID NCT01941368). PMID:24782684
Antunes, Hanna Karen M.; De Mello, Marco Túlio; de Aquino Lemos, Valdir; Santos-Galduróz, Ruth Ferreira; Camargo Galdieri, Luciano; Amodeo Bueno, Orlando Francisco; Tufik, Sergio; D'Almeida, Vânia
2015-01-01
Background Physical exercise influences homocysteine (Hcy) concentrations, cognitive function and the metabolic profile. The purpose of this study was to investigate the influence of regular physical exercise on Hcy levels, the metabolic profile and cognitive function in healthy elderly males before and after an endurance exercise program. Methods Forty-five healthy and sedentary volunteers were randomized into 2 groups: (1) a control group asked not to change their normal everyday activities and not to start any regular physical exercise program and (2) an experimental group trained at a heart rate intensity corresponding to ventilatory threshold 1 (VT-1) for 60 min/day 3 times weekly on alternate days for 6 months using a cycle ergometer. All volunteers underwent cognitive evaluations, blood sample analyses and ergospirometric assessments. Results A significant improvement in cognitive function was observed in the experimental group compared with the control group (p < 0.05). No significant changes in Hcy levels were observed in the experimental group (p > 0.05), but there was a significant increase in peak oxygen consumption and workload at VT-1 as well as a significant improvement in cholesterol, triglycerides, HDL, glucose, alkaline phosphatase, urea, T3, T4 and prostate-specific antigen compared with the control group (p < 0.05). Conclusion The data suggest that a physical exercise program does not reduce Hcy levels in healthy elderly males, although it improves the cardiovascular and metabolic profile as well as cognitive function. PMID:25759715
Impact of backpack load on ventilatory function among 9-12 year old Saudi girls.
Al-Katheri, Abeer E
2013-12-01
To explore the backpack load as a percentile of body weight (BW) and its impact on ventilatory function including tidal volume (Vt), vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in one second (FEV1), FEV1/FVC, peak expiratory flow (PEF), and maximum voluntary ventilation (MVV) among 9-12 year old Saudi girls. This is a prospective, experimental study of 91 Saudi girls aged between 9-12 years from primary schools in Riyadh, Saudi Arabia. The study took place in King Saud University, Riyadh, Saudi Arabia between April 2012 and May 2012. Ventilatory function was measured under 2 conditions: a free standing position without carrying a backpack, and while carrying a backpack. The backpack load observed was 13.8% of the BW, which is greater than the recommended limit (10% BW). All values of ventilatory function were significantly reduced after carrying the backpack (p<0.001) with the exception of FEV1/FVC (p>0.178). The reduction was observed even with the lowest backpack load (7.4% BW). A significant reduction was reported for most of the ventilatory function parameters while carrying the backpack. This reduction was apparent even with the least backpack load (7.4% BW) carried by the participants. This study recommends that the upper safe limit of backpack load carried by Saudi girls aged 9-12 years should be less than 7.4% of BW.
Brain stem NO modulates ventilatory acclimatization to hypoxia in mice.
El Hasnaoui-Saadani, R; Alayza, R Cardenas; Launay, T; Pichon, A; Quidu, P; Beaudry, M; Léon-Velarde, F; Richalet, J P; Duvallet, A; Favret, F
2007-11-01
The objective of our study was to assess the role of neuronal nitric oxide synthase (nNOS) in the ventilatory acclimatization to hypoxia. We measured the ventilation in acclimatized Bl6/CBA mice breathing 21% and 8% oxygen, used a nNOS inhibitor, and assessed the expression of N-methyl-d-aspartate (NMDA) glutamate receptor and nNOS (mRNA and protein). Two groups of Bl6/CBA mice (n = 60) were exposed during 2 wk either to hypoxia [barometric pressure (PB) = 420 mmHg] or normoxia (PB = 760 mmHg). At the end of exposure the medulla was removed to measure the concentration of nitric oxide (NO) metabolites, the expression of NMDA-NR1 receptor, and nNOS by real-time RT-PCR and Western blot. We also measured the ventilatory response [fraction of inspired O(2) (Fi(O(2))) = 0.21 and 0.08] before and after S-methyl-l-thiocitrulline treatment (SMTC, nNOS inhibitor, 10 mg/kg ip). Chronic hypoxia caused an increase in ventilation that was reduced after SMTC treatment mainly through a decrease in tidal volume (Vt) in normoxia and in acute hypoxia. However, the difference observed in the magnitude of acute hypoxic ventilatory response [minute ventilation (Ve) 8% - Ve 21%] in acclimatized mice was not different. Acclimatization to hypoxia induced a rise in NMDA receptor as well as in nNOS and NO production. In conclusion, our study provides evidence that activation of nNOS is involved in the ventilatory acclimatization to hypoxia in mice but not in the hypoxic ventilatory response (HVR) while the increased expression of NMDA receptor expression in the medulla of chronically hypoxic mice plays a role in acute HVR. These results are therefore consistent with central nervous system plasticity, partially involved in ventilatory acclimatization to hypoxia through nNOS.
Association Between Sarcopenia-Related Phenotypes and Aerobic Capacity Indexes of Older Women
de Oliveira, Ricardo Jacó; Bottaro, Martim; Motta, Antonio Marco; Pitanga, Francisco; Guido, Marcelo; Leite, Tailce Kaley Moura; Bezerra, Lídia Mara Aguiar; Lima, Ricardo Moreno
2009-01-01
The purpose of the present study was to examine the association between fat-free mass (FFM), quadriceps strength and sarcopenia with aerobic fitness indexes of elderly women. A total of 189 volunteers (66.7 ± 5.46 years) underwent aerobic capacity measurement through a symptom-limited cardiopulmonary exercise test to determine their individual ventilatory thresholds (VT) and peak oxygen uptake (VO2 peak). Quadriceps muscle strength was assessed using an isokinetic dynamometer. Also, dual energy X-ray absorptiometry was used to assess FFM and cutoff values were used to classify subjects as sarcopenic or nonsarcopenic. Correlations, student t-test and analysis of variance were used to examine the data. Both FFM and quadriceps strength variables were positively and significantly correlated with the measured aerobic capacity indexes. These results were observed for peak exercise as well as for ventilatory thresholds. Individuals classified as sarcopenic presented significantly lower muscle strength and (VO2 peak) when compared to nonsarcopenic. It can be concluded that FFM and quadriceps strength are significantly related to aerobic capacity indexes in older women, and that besides presenting lower quadriceps strength, women classified as sarcopenic have lower peak oxygen consumption. Taken together, the present results indicate that both FFM and strength play a role in the age-related decline of aerobic capacity. Key points Maximal aerobic capacity, generally expressed as peak oxygen consumption (VO2 peak), declines with advancing age and this process is associated with an increased risk for cardiovascular diseases. Also, the aging process is associated with a progressive loss of muscle mass and strength and this phenomenon has been referred to as Sarcopenia. Sarcopenia has been described in both elderly men and women and has been linked to multiple negative clinical outcomes. The present study provide evidence that muscle-related phenotypes are associated with aerobic capacity of older individuals, thus suggesting that sarcopenia explains in part the decline in aerobic fitness observed with advancing age. PMID:24149995
Ventilatory response to hypercarbia in newborns of smoking and substance-misusing mothers.
Ali, Kamal; Wolff, Kim; Peacock, Janet L; Hannam, Simon; Rafferty, Gerrard F; Bhat, Ravindra; Greenough, Anne
2014-07-01
Infants of mothers who smoked (S) or substance misused (SM) during pregnancy have an increased risk of sudden infant death syndrome (SIDS). To test the hypothesis that infants of S and SM mothers compared with infants of non-substance-misusing, nonsmoking mothers (control subjects) would have a reduced ventilatory response to hypercarbia and that any reduction would be greater in the SM infants. Infants were assessed before maternity/neonatal unit discharge. Maternal and infant urine samples were obtained and tested for cotinine, cannabinoids, opiates, amphetamines, methadone, cocaine, and benzodiazepines. Respiratory flow and Vt were measured using a pneumotachograph inserted into a face mask placed over the infant's mouth and nose. The ventilatory responses to three levels of inspired carbon dioxide (0 [baseline], 2, and 4% CO2) were assessed. Twenty-three SM, 34 S, and 22 control infants were assessed. The birth weight of the control subjects was higher than the SM and S infants (P = 0.017). At baseline, SM infants had a higher respiratory rate (P = 0.003) and minute volume (P = 0.007) compared with control subjects and S infants. Both the SM and S infants had a lower ventilatory response to 2% (P < 0.001) and 4% (P < 0.001) CO2 than the control subjects. The ventilatory response to CO2 was lower in the SM infants compared with the S infants (P = 0.009). These results are consistent with infants of smoking mothers and substance misuse/smoking mothers having a dampened ventilatory response to hypercarbia, which is particularly marked in the latter group.
Colombo, Davide; Cammarota, Gianmaria; Bergamaschi, Valentina; De Lucia, Marta; Corte, Francesco Della; Navalesi, Paolo
2008-11-01
Neurally adjusted ventilatory assist (NAVA) is a new mode wherein the assistance is provided in proportion to diaphragm electrical activity (EAdi). We assessed the physiologic response to varying levels of NAVA and pressure support ventilation (PSV). ICU of a University Hospital. Fourteen intubated and mechanically ventilated patients. DESIGN AND PROTOCOL: Cross-over, prospective, randomized controlled trial. PSV was set to obtain a VT/kg of 6-8 ml/kg with an active inspiration. NAVA was matched with a dedicated software. The assistance was decreased and increased by 50% with both modes. The six assist levels were randomly applied. Arterial blood gases (ABGs), tidal volume (VT/kg), peak EAdi, airway pressure (Paw), neural and flow-based timing. Asynchrony was calculated using the asynchrony index (AI). There was no difference in ABGs regardless of mode and assist level. The differences in breathing pattern, ventilator assistance, and respiratory drive and timing between PSV and NAVA were overall small at the two lower assist levels. At the highest assist level, however, we found greater VT/kg (9.1 +/- 2.2 vs. 7.1 +/- 2 ml/kg, P < 0.001), and lower breathing frequency (12 +/- 6 vs. 18 +/- 8.2, P < 0.001) and peak EAdi (8.6 +/- 10.5 vs. 12.3 +/- 9.0, P < 0.002) in PSV than in NAVA; we found mismatch between neural and flow-based timing in PSV, but not in NAVA. AI exceeded 10% in five (36%) and no (0%) patients with PSV and NAVA, respectively (P < 0.05). Compared to PSV, NAVA averted the risk of over-assistance, avoided patient-ventilator asynchrony, and improved patient-ventilator interaction.
NASA Astrophysics Data System (ADS)
Zhang, Z.; Cardwell, D.; Sasikumar, A.; Kyle, E. C. H.; Chen, J.; Zhang, E. X.; Fleetwood, D. M.; Schrimpf, R. D.; Speck, J. S.; Arehart, A. R.; Ringel, S. A.
2016-04-01
The impact of proton irradiation on the threshold voltage (VT) of AlGaN/GaN heterostructures is systematically investigated to enhance the understanding of a primary component of the degradation of irradiated high electron mobility transistors. The value of VT was found to increase monotonically as a function of 1.8 MeV proton fluence in a sub-linear manner reaching 0.63 V at a fluence of 1 × 1014 cm-2. Silvaco Atlas simulations of VT shifts caused by GaN buffer traps using experimentally measured introduction rates, and energy levels closely match the experimental results. Different buffer designs lead to different VT dependences on proton irradiation, confirming that deep, acceptor-like defects in the GaN buffer are primarily responsible for the observed VT shifts. The proton irradiation induced VT shifts are found to depend on the barrier thickness in a linear fashion; thus, scaling the barrier thickness could be an effective way to reduce such degradation.
de Lira, Claudio Andre Barbosa; Peixinho-Pena, Luiz Fernando; Vancini, Rodrigo Luiz; de Freitas Guina Fachina, Rafael Júlio; de Almeida, Alexandre Aparecido; Andrade, Marília dos Santos; da Silva, Antonio Carlos
2013-01-01
The present study aimed to describe heart rate (HR) responses during a simulated Olympic boxing match and examine physiological parameters of boxing athletes. Ten highly trained Olympic boxing athletes (six men and four women) performed a maximal graded exercise test on a motorized treadmill to determine maximal oxygen uptake (52.2 mL · kg−1 · min−1 ± 7.2 mL · kg−1 · min−1) and ventilatory thresholds 1 and 2. Ventilatory thresholds 1 and 2 were used to classify the intensity of exercise based on respective HR during a boxing match. In addition, oxygen uptake (V̇O2) was estimated during the match based on the HR response and the HR-V̇O2 relationship obtained from a maximal graded exercise test for each participant. On a separate day, participants performed a boxing match lasting three rounds, 2 minutes each, with a 1-minute recovery period between each round, during which HR was measured. In this context, HR and V̇O2 were above ventilatory threshold 2 during 219.8 seconds ± 67.4 seconds. There was an increase in HR and V̇O2 as a function of round (round 3 < round 2 < round 1, P < 0.0001). These findings may direct individual training programs for boxing practitioners and other athletes. PMID:24379723
de Lira, Claudio Andre Barbosa; Peixinho-Pena, Luiz Fernando; Vancini, Rodrigo Luiz; de Freitas Guina Fachina, Rafael Júlio; de Almeida, Alexandre Aparecido; Andrade, Marília Dos Santos; da Silva, Antonio Carlos
2013-01-01
The present study aimed to describe heart rate (HR) responses during a simulated Olympic boxing match and examine physiological parameters of boxing athletes. Ten highly trained Olympic boxing athletes (six men and four women) performed a maximal graded exercise test on a motorized treadmill to determine maximal oxygen uptake (52.2 mL · kg(-1) · min(-1) ± 7.2 mL · kg(-1) · min(-1)) and ventilatory thresholds 1 and 2. Ventilatory thresholds 1 and 2 were used to classify the intensity of exercise based on respective HR during a boxing match. In addition, oxygen uptake (V̇O2) was estimated during the match based on the HR response and the HR-V̇O2 relationship obtained from a maximal graded exercise test for each participant. On a separate day, participants performed a boxing match lasting three rounds, 2 minutes each, with a 1-minute recovery period between each round, during which HR was measured. In this context, HR and V̇O2 were above ventilatory threshold 2 during 219.8 seconds ± 67.4 seconds. There was an increase in HR and V̇O2 as a function of round (round 3 < round 2 < round 1, P < 0.0001). These findings may direct individual training programs for boxing practitioners and other athletes.
Wilke, Carolina F; Ramos, Guilherme P; Pacheco, Diogo A S; Santos, Weslley H M; Diniz, Mateus S L; Gonçalves, Gabriela G P; Marins, João C B; Wanner, Samuel P; Silami-Garcia, Emerson
2016-08-01
Wilke, CF, Ramos, GP, Pacheco, DAS, Santos, WHM, Diniz, MSL, Gonçalves, GGP, Marins, JCB, Wanner, SP, and Silami-Garcia, E. Metabolic demand and internal training load in technical-tactical training sessions of professional futsal players. J Strength Cond Res 30(8): 2330-2340, 2016-The aim of the study was to characterize aspects of technical-tactical training sessions of a professional futsal team. We addressed 4 specific aims: characterize the metabolic demands and intensity of these training sessions, compare the training intensity among players of different positions, compare the intensity of different futsal-specific activities (4 × 4, 6 × 4, and match simulation), and investigate the association between an objective (training impulse; TRIMP) and a subjective method (session rating of perceived exertion; sRPE) of measuring a player's internal training load. Twelve top-level futsal players performed an incremental exercise to determine their maximal oxygen consumption, maximal heart rate (HRmax), ventilatory threshold (VT), and respiratory compensation point (RCP). Each player's HR and RPE were measured and used to calculate energy expenditure, TRIMP, and sRPE during 37 training sessions over 8 weeks. The average intensity was 74 ± 4% of HRmax, which corresponded to 9.3 kcal·min. The players trained at intensities above the RCP, between the RCP and VT and below the VT for 20 ± 8%, 28 ± 6%, and 51 ± 10% of the session duration, respectively. Wingers, defenders, and pivots exercised at a similar average intensity but with different intensity distributions. No difference in intensity was found between the 3 typical activities. A strong correlation between the average daily TRIMP and sRPE was observed; however, this relationship was significant for only 4 of 12 players, indicating that sRPE is a useful tool for monitoring training loads but that it should be interpreted for each player individually rather than collectively.
Physiologic responses during indoor cycling.
Battista, Rebecca A; Foster, Carl; Andrew, Jessica; Wright, Glenn; Lucia, Alejandro; Porcari, John P
2008-07-01
During the last decade, there has been active interest in indoor cycling (e.g., spinning) as a method of choreographed group exercise. Recent studies have suggested that exercise intensity during indoor cycling may be quite high and may transiently exceed Vo2max. This study sought to confirm these findings, as the apparent high intensity of indoor cycling has implications for both the efficacy and the risk of indoor cycling as an exercise method. Twenty healthy female students performed an incremental exercise test to define Vo2max and performed 2 videotaped indoor exercise classes lasting 45 minutes and 35 minutes. Vo2, heart rate (HR), and rating of perceived exertion (RPE) were measured during the indoor cycling classes, with Vo2 data integrated in 30-second intervals. The mean %Vo2max during the indoor cycling classes was modest (74 +/- 14% Vo2max and 66 +/- 14%Vo2max, respectively). However, 52% and 35% of the time during the 45- and 35-minute classes was spent at intensities greater than the ventilatory threshold (VT). The HR response indicated that 35% and 38% of the session time was above the HR associated with VT. In 10 of the 40 exercise sessions, there were segments in which the momentary Vo2 exceeded Vo2max observed during incremental testing, and the cumulative time with exercise intensity greater than Vo2max ranged from 0.5 to 14.0 minutes. It can be concluded that although the intensity of indoor cycling in healthy, physically active women is moderate, there are frequent observations of transient values of Vo2 exceeding Vo2max, and a substantial portion of the exercise bouts at intensities greater than VT. As such, the data suggest that indoor cycling must be considered a high-intensity exercise mode of exercise training, which has implications for both efficacy and risk.
Blain, G; Meste, O; Bouchard, T; Bermon, S
2005-07-01
To test whether ventilatory thresholds, measured during an exercise test, could be assessed using time varying analysis of respiratory sinus arrhythmia frequency (f(RSA)). Fourteen sedentary subjects and 12 endurance athletes performed a graded and maximal exercise test on a cycle ergometer: initial load 75 W (sedentary subjects) and 150 W (athletes), increments 37.5 W/2 min. f(RSA) was extracted from heart period series using an evolutive model. First (T(V1)) and second (T(V2)) ventilatory thresholds were determined from the time course curves of ventilation and ventilatory equivalents for O(2) and CO(2). f(RSA) was accurately extracted from all recordings and positively correlated to respiratory frequency (r = 0.96 (0.03), p<0.01). In 21 of the 26 subjects, two successive non-linear increases were determined in f(RSA), defining the first (T(RSA1)) and second (T(RSA2)) f(RSA) thresholds. When expressed as a function of power, T(RSA1) and T(RSA2) were not significantly different from and closely linked to T(V1) (r = 0.99, p<0.001) and T(V2) (r = 0.99, p<0.001), respectively. In the five remaining subjects, only one non-linear increase was observed close to T(V2). Significant differences (p<0.04) were found between athlete and sedentary groups when T(RSA1) and T(RSA2) were expressed in terms of absolute and relative power and percentage of maximal aerobic power. In the sedentary group, T(RSA1) and T(RSA2) were 150.3 (18.7) W and 198.3 (28.8) W, respectively, whereas in the athlete group T(RSA1) and T(RSA2) were 247.3 (32.8) W and 316.0 (28.8) W, respectively. Dynamic analysis of f(RSA) provides a useful tool for identifying ventilatory thresholds during graded and maximal exercise test in sedentary subjects and athletes.
Blain, G; Meste, O; Bouchard, T; Bermon, S; Segura, R.
2005-01-01
Objective: To test whether ventilatory thresholds, measured during an exercise test, could be assessed using time varying analysis of respiratory sinus arrhythmia frequency (fRSA). Methods: Fourteen sedentary subjects and 12 endurance athletes performed a graded and maximal exercise test on a cycle ergometer: initial load 75 W (sedentary subjects) and 150 W (athletes), increments 37.5 W/2 min. fRSA was extracted from heart period series using an evolutive model. First (TV1) and second (TV2) ventilatory thresholds were determined from the time course curves of ventilation and ventilatory equivalents for O2 and CO2. Results: fRSA was accurately extracted from all recordings and positively correlated to respiratory frequency (r = 0.96 (0.03), p<0.01). In 21 of the 26 subjects, two successive non-linear increases were determined in fRSA, defining the first (TRSA1) and second (TRSA2) fRSA thresholds. When expressed as a function of power, TRSA1 and TRSA2 were not significantly different from and closely linked to TV1 (r = 0.99, p<0.001) and TV2 (r = 0.99, p<0.001), respectively. In the five remaining subjects, only one non-linear increase was observed close to TV2. Significant differences (p<0.04) were found between athlete and sedentary groups when TRSA1 and TRSA2 were expressed in terms of absolute and relative power and percentage of maximal aerobic power. In the sedentary group, TRSA1 and TRSA2 were 150.3 (18.7) W and 198.3 (28.8) W, respectively, whereas in the athlete group TRSA1 and TRSA2 were 247.3 (32.8) W and 316.0 (28.8) W, respectively. Conclusions: Dynamic analysis of fRSA provides a useful tool for identifying ventilatory thresholds during graded and maximal exercise test in sedentary subjects and athletes. PMID:15976169
The effects of locomotor-respiratory coupling on the pattern of breathing in horses.
Lafortuna, C L; Reinach, E; Saibene, F
1996-01-01
1. To investigate the effect of locomotor activity on the pattern of breathing in quadrupeds, ventilatory response was studied in four healthy horses during horizontal and inclined (7%) treadmill exercise at different velocities (1.4-6.9 m s(-1)) and during chemical stimulation with a rebreathing method. Stride frequency (f(s)) and locomotor-respiratory coupling (LRC) were also simultaneously determined by means of video recordings synchronized with respiratory events. 2. Tidal volume (V(T)) was positively correlated with pulmonary ventilation (V(E)) but significantly different linear regression equations were found between the experimental conditions (P < 0.0001), since the chemical hyperventilation was mainly due to increases in V(T), whereas the major contribution to exercise hyperpnoea came from changes in respiratory frequency (f(R)). 3. The average f(R) at each exercise level was not significantly different from f(S), although there was not always a tight 1:1 LRC. At constant speeds, f(S) was independent of the treadmill slope and hence the greater V(E) during inclined exercise was due to increased V(T). 4. At any ventilatory level, the differences in breathing patterns between locomotion and rebreathing or locomotion at different slopes derived from different set points of the inspiratory off-switch mechanism. 5. The percentage of single breaths entrained with locomotor rhythm rose progressively and significantly with treadmill speed (P < 0.0001) up to a 1:1 LRC and was significantly affected by treadmill slope (P < 0.001). 6. A LRC of 1:1 was systematically observed at canter (10 out of 10 trials) and sometimes at trot (5 out of 14) and it entailed (i) a 4- to 5-fold reduction in both V(T) and f(R) variability, and (ii) a gait-specific phase locking of inspiratory onset during the locomotor cycle. 7. It is concluded that different patterns of breathing are employed during locomotion and rebreathing due to the interference between locomotor and respiratory functions, which may play a role in the optimization and control of exercise ventilation in horses. PMID:9019552
The Yo-Yo intermittent recovery test in basketball players.
Castagna, Carlo; Impellizzeri, Franco M; Rampinini, Ermanno; D'Ottavio, Stefano; Manzi, Vincenzo
2008-04-01
The purpose of this study was to examine the physiological correlates of the Yo-Yo intermittent recovery test level 1 (Yo-Yo IR1) in basketball players. Twenty-two male basketball players (means+/-S.D., body mass 72.4+/-11.4kg, height 181.7+/-6.9cm, age 16.8+/-2.0 years) were tested for maximal oxygen uptake (VO(2max)), ventilatory threshold (VT) and running economy (RE) on a motorized treadmill. Lower limb explosive strength and anaerobic-capacity was assessed using vertical jumps (CMJ), 15m shuttle running sprint (15mSR) and line drill (LD), respectively. The same test battery was replicated after an experimental basketball game in order to assess selective effect of fatigue on physical performance. Pre to post-game CMJ (40.3+/-5.7 versus 39.9+/-5.9cm) and 15mSR (5.80+/-0.25 versus 5.77+/-0.22s) performances were not significantly different (p>0.05). LD performance decreased significantly post-game (from 26.7+/-1.3 to 27.7+/-2.7s, p<0.001). Yo-Yo IR1 performances (m) were significantly related to VO(2max) (r=0.77, p=0.0001), speed at VO(2max) (r=0.71, p=0.0001) and %VO(2max) at VT (r=-0.60, p=0.04). Yo-Yo IR1 performance was significantly correlated to post-game LD decrements (r=-0.52, p=0.02). These findings show that Yo-Yo IR1 may be considered as a valid basketball-specific test for the assessment of aerobic fitness and game-related endurance.
Niven, Ailsa; Thow, Jacqueline; Holroyd, Jack; Turner, Anthony P; Phillips, Shaun M
2018-09-01
This study compared affective responses to low volume high-intensity interval exercise (HIIE), moderate-intensity continuous exercise (MICE) and high-intensity continuous exercise (HICE). Twelve untrained males ([Formula: see text] 48.2 ± 6.7 ml·kg -1 ·min -1 ) completed MICE (30 min cycle at 85% of ventilatory threshold (VT)), HICE (cycle at 105% of VT matched with MICE for total work), and HIIE (10 x 6 s cycle sprints with 60 s recovery). Affective valence and perceived activation were measured before exercise, post warm-up, every 20% of exercise time, and 1, 5, 10, and 15 min post-exercise. Affective valence during exercise declined by 1.75 ± 2.42, 1.17 ± 1.99, and 0.42 ± 1.38 units in HICE, HIIE, and MICE, respectively, but was not statistically influenced by trial (P = 0.35), time (P = 0.06), or interaction effect (P = 0.08). Affective valence during HICE and HIIE was consistently less positive than MICE. Affective valence post-exercise was not statistically influenced by trial (P = 0.10) and at 5 min post-exercise exceeded end-exercise values (P = 0.048). Circumplex profiles showed no negative affect in any trial. Affective responses to low volume HIIE are similar to HICE but remain positive and rebound rapidly, suggesting it may be a potential alternative exercise prescription.
Training Prescription Guided by Heart Rate Variability in Cycling.
Javaloyes, Alejandro; Sarabia, Jose Manuel; Lamberts, Robert Patrick; Moya-Ramon, Manuel
2018-05-29
Road cycling is a sport with extreme physiological demands. Therefore, there is a need to find new strategies to improve performance. Heart rate variability (HRV) has been suggested as an effective alternative for prescribing training load against predefined training programs. The purpose of this study is to examine the effect of training prescription based on HRV in road cycling performance. Seventeen well-trained cyclists participated in this study. After an initial evaluation week (EW), cyclists performed 4 baseline weeks (BW) of standardized training to establish their resting HRV. Then, cyclists were divided into two groups, a HRV-guided group (HRV-G) and a traditional periodization group (TRAD) and they carried out 8 training weeks (TW). Cyclists performed two EW, after and before TW. During the EW, cyclists performed: (1) a graded exercise test to assess VO2max, peak power output (PPO) and ventilatory thresholds with their corresponding power output (VT1, VT2, WVT1, and WVT2, respectively) and (2) a 40-min simulated time-trial. HRV-G improved PPO (5.1 ± 4.5 %; p = 0.024), WVT2 (13.9 ± 8.8 %; p = 0.004) and 40TT (7.3 ± 4.5 %; p = 0.005). VO2max and WVT1 remained similar. TRAD did not improve significantly after TW. There were no differences between groups. However, magnitude-based inference analysis showed likely beneficial and possibly beneficial effects for HRV-G instead of TRAD in 40TT and PPO, respectively. Daily training prescription based on HRV could result in a better performance enhancement than a traditional periodization in well-trained cyclists.
Prediction of maximal lactate steady state in runners with an incremental test on the field.
Leti, Thomas; Mendelson, Monique; Laplaud, David; Flore, Patrice
2012-01-01
During a maximal incremental ergocycle test, the power output associated with Respiratory Exchange Ratio equal to 1.00 (RER = 1.00) predicts maximal lactate steady state (MLSS). We hypothesised that these results are transferable for runners on the field. Fourteen runners performed a maximal progressive test, to assess the speed associated with RER = 1.00, and several 30 minutes constant velocity tests to determine the speed at MLSS. We observed that the speeds at RER = 1.00, at the second ventilatory threshold (VT2) and at MLSS did not differ (15.7 ± 1.1 km · h⁻¹, 16.2 ± 1.4 km · h⁻¹, 15.5 ± 1.1 km · h⁻¹ respectively). The speed associated with RER = 1.00 was better correlated with that at MLSS (r = 0.79; p = 0.0008) than that at VT2 (r = 0.73; p = 0.002). Neither the concentration of blood lactate nor the heart rate differed between the speed at RER = 1.00 and that at MLSS from the 10th and the 30th minute of the constant velocity test. Bland and Altman analysis showed a fair agreement between the speed at MLSS and that at RER (0.2 ± 1.4 km · h⁻¹). This study demonstrated that the speed associated with RER = 1.00 determined during maximal progressive track running allows a fair estimation of the speed associated with MLSS, markedly decreasing the burden of numerous invasive tests required to assess it.
Analytical model for the threshold voltage of III-V nanowire transistors including quantum effects
NASA Astrophysics Data System (ADS)
Marin, E. G.; Ruiz, F. G.; Tienda-Luna, I. M.; Godoy, A.; Gámiz, F.
2014-02-01
In this work we propose an analytical model for the threshold voltage (VT) of III-V cylindrical nanowires, that takes into consideration the two dimensional quantum confinement of the carriers, the Fermi-Dirac statistics, the wave-function penetration into the gate insulator and the non-parabolicity of the conduction band structure. A simple expression for VT is obtained assuming some suitable approximations. The model results are compared to those of a 2D self consistent Schrödinger-Poisson solver, demonstrating a good fit for different III-V materials, insulator thicknesses and nanowire sizes with diameter down to 5 nm. The VT dependence on the confinement effective mass is discussed. The different contributions to VT are analyzed showing significant variations among different III-V materials.
Tempest, Gavin D; Eston, Roger G; Parfitt, Gaynor
2014-01-01
The dose-response effects of the intensity of exercise upon the potential regulation (through top-down processes) of affective (pleasure-displeasure) responses in the prefrontal cortex during an incremental exercise protocol have not been explored. This study examined the functional capacity of the prefrontal cortex (reflected by haemodynamics using near infrared spectroscopy) and affective responses during exercise at different intensities. Participants completed an incremental cycling exercise test to exhaustion. Changes (Δ) in oxygenation (O2Hb), deoxygenation (HHb), blood volume (tHb) and haemoglobin difference (HbDiff) were measured from bilateral dorsal and ventral prefrontal areas. Affective responses were measured every minute during exercise. Data were extracted at intensities standardised to: below ventilatory threshold, at ventilatory threshold, respiratory compensation point and the end of exercise. During exercise at intensities from ventilatory threshold to respiratory compensation point, ΔO2Hb, ΔHbDiff and ΔtHb were greater in mostly ventral than dorsal regions. From the respiratory compensation point to the end of exercise, ΔO2Hb remained stable and ΔHbDiff declined in dorsal regions. As the intensity increased above the ventilatory threshold, inverse associations between affective responses and oxygenation in (a) all regions of the left hemisphere and (b) lateral (dorsal and ventral) regions followed by the midline (ventral) region in the right hemisphere were observed. Differential activation patterns occur within the prefrontal cortex and are associated with affective responses during cycling exercise.
Tempest, Gavin D.; Eston, Roger G.; Parfitt, Gaynor
2014-01-01
The dose-response effects of the intensity of exercise upon the potential regulation (through top-down processes) of affective (pleasure-displeasure) responses in the prefrontal cortex during an incremental exercise protocol have not been explored. This study examined the functional capacity of the prefrontal cortex (reflected by haemodynamics using near infrared spectroscopy) and affective responses during exercise at different intensities. Participants completed an incremental cycling exercise test to exhaustion. Changes (Δ) in oxygenation (O2Hb), deoxygenation (HHb), blood volume (tHb) and haemoglobin difference (HbDiff) were measured from bilateral dorsal and ventral prefrontal areas. Affective responses were measured every minute during exercise. Data were extracted at intensities standardised to: below ventilatory threshold, at ventilatory threshold, respiratory compensation point and the end of exercise. During exercise at intensities from ventilatory threshold to respiratory compensation point, ΔO2Hb, ΔHbDiff and ΔtHb were greater in mostly ventral than dorsal regions. From the respiratory compensation point to the end of exercise, ΔO2Hb remained stable and ΔHbDiff declined in dorsal regions. As the intensity increased above the ventilatory threshold, inverse associations between affective responses and oxygenation in (a) all regions of the left hemisphere and (b) lateral (dorsal and ventral) regions followed by the midline (ventral) region in the right hemisphere were observed. Differential activation patterns occur within the prefrontal cortex and are associated with affective responses during cycling exercise. PMID:24788166
A short latency vestibular evoked potential (VsEP) produced by bone-conducted acoustic stimulation
NASA Astrophysics Data System (ADS)
McAngus Todd, Neil P.; Rosengren, Sally M.; Colebatch, James G.
2003-12-01
In this paper data are presented from an experiment which provides evidence for the existence of a short latency, acoustically evoked potential of probable vestibular origin. The experiment was conducted in two phases using bone-conducted acoustic stimulation. In the first phase subjects were stimulated with 6-ms, 500-Hz tone bursts in order to obtain the threshold VT for vestibular evoked myogenic potentials (VEMP). It was confirmed that the difference between bone-conducted auditory and acoustic vestibular thresholds was slightly over 30 dB. The estimated threshold was then used as a reference value in the second part of the experiment to stimulate subjects over a range of intensities from -6 to +18 dB (re:VT). Averaged EEG recordings were made with eight Ag/AgCl electrodes placed on the scalp at Fpz, F3, F4, F7, F8, Cz, T3, and T4 according to the 10-20 system. Below VT auditory midlatency responses (MLRs) were observed. Above VT two additional potentials appeared: a positivity at about 10 ms (P10) which was maximal at Cz, and a negativity at about 15 ms (N15) which was maximal at Fpz. Extrapolation of the growth functions for the P10 and N15 indicated a threshold close to VT, consistent with a vestibular origin of these potentials. Given the low threshold of vestibular acoustic sensitivity it is possible that this mode may make a contribution to the detection of and affective responses to loud low frequency sounds. The evoked potentials may also have application as a noninvasive and nontraumatic test of vestibular projections to the cortex.
Breslin, E H; Adams, E; Lutz, A; Roy, C
1993-06-01
Many daily activities, from basic grooming to employment tasks, require adequate unsupported arm endurance (UAE). We developed an electromechanical device to measure UAE endurance. The purpose of this study was to standardize the instrument for two rates of arm motion, moderate and slow, in 18 normal adult subjects (FEVI = 3.7L +/- .78, FVC = 4.2L +/- .74, FEV1/FVC = 1.1 +/- .08). Exercise endurance limits, and the following metabolic, ventilatory, and sensation responses were determined at rest prior to exercise and at end-exercise limits for both rates of UAE:minute ventilation (Ve), tidal volume (VT), respiratory rate (RR), duty cycle (Ti/Ttot), oxygen uptake (VO2), carbon dioxide production (VCO2), inspiratory flow (VT/Ti), heart rate (HR), and visual analog scale measurements (VAS) of dyspnea (D), respiratory effort (RE), and arm fatigue (AF). Significance increases from baseline rest were shown at the endurance limits for both rates of UAE in: VO2, VCO2, Ve, VT, RR, VT/Ti, HR, VAS-D, VAS-RE, and VAS-AF. There were no changes in Ti/Ttot and SaO2 with UAE. Peak VO2, RR, Ve, VT/Ti, and VAS-D with moderate exercise were significantly greater than slow UAE; and there was a trend increase in peak HR for moderate as opposed to slow rate UAE. Despite these differences, the endurance time between the two rates of UAE were similar. These data provide standards against which UAE in COPD can be evaluated.
Mechanical ventilation with high tidal volume induces inflammation in patients without lung disease.
Pinheiro de Oliveira, Roselaine; Hetzel, Marcio Pereira; dos Anjos Silva, Mauro; Dallegrave, Daniele; Friedman, Gilberto
2010-01-01
Mechanical ventilation (MV) with high tidal volumes may induce or aggravate lung injury in critical ill patients. We compared the effects of a protective versus a conventional ventilatory strategy, on systemic and lung production of tumor necrosis factor-alpha (TNF-alpha) and interleukin-8 (IL-8) in patients without lung disease. Patients without lung disease and submitted to mechanical ventilation admitted to one trauma and one general adult intensive care unit of two different university hospitals were enrolled in a prospective randomized-control study. Patients were randomized to receive MV either with tidal volume (VT) of 10 to 12 ml/kg predicted body weight (high VT group) (n = 10) or with VT of 5 to 7 ml/kg predicted body weight (low VT group) (n = 10) with an oxygen inspiratory fraction (FIO2) enough to keep arterial oxygen saturation >90% with positive end-expiratory pressure (PEEP) of 5 cmH2O during 12 hours after admission to the study. TNF-alpha and IL-8 concentrations were measured in the serum and in the bronchoalveolar lavage fluid (BALF) at admission and after 12 hours of study observation time. Twenty patients were enrolled and analyzed. At admission or after 12 hours there were no differences in serum TNF-alpha and IL-8 between the two groups. While initial analysis did not reveal significant differences, standardization against urea of logarithmic transformed data revealed that TNF-alpha and IL-8 levels in bronchoalveolar lavage (BAL) fluid were stable in the low VT group but increased in the high VT group (P = 0.04 and P = 0.03). After 12 hours, BALF TNF-alpha (P = 0.03) and BALF IL-8 concentrations (P = 0.03) were higher in the high VT group than in the low VT group. The use of lower tidal volumes may limit pulmonary inflammation in mechanically ventilated patients even without lung injury. NCT00935896.
Quantifying the Arousal Threshold Using Polysomnography in Obstructive Sleep Apnea.
Sands, Scott A; Terrill, Philip I; Edwards, Bradley A; Taranto Montemurro, Luigi; Azarbarzin, Ali; Marques, Melania; de Melo, Camila M; Loring, Stephen H; Butler, James P; White, David P; Wellman, Andrew
2018-01-01
Precision medicine for obstructive sleep apnea (OSA) requires noninvasive estimates of each patient's pathophysiological "traits." Here, we provide the first automated technique to quantify the respiratory arousal threshold-defined as the level of ventilatory drive triggering arousal from sleep-using diagnostic polysomnographic signals in patients with OSA. Ventilatory drive preceding clinically scored arousals was estimated from polysomnographic studies by fitting a respiratory control model (Terrill et al.) to the pattern of ventilation during spontaneous respiratory events. Conceptually, the magnitude of the airflow signal immediately after arousal onset reveals information on the underlying ventilatory drive that triggered the arousal. Polysomnographic arousal threshold measures were compared with gold standard values taken from esophageal pressure and intraoesophageal diaphragm electromyography recorded simultaneously (N = 29). Comparisons were also made to arousal threshold measures using continuous positive airway pressure (CPAP) dial-downs (N = 28). The validity of using (linearized) nasal pressure rather than pneumotachograph ventilation was also assessed (N = 11). Polysomnographic arousal threshold values were correlated with those measured using esophageal pressure and diaphragm EMG (R = 0.79, p < .0001; R = 0.73, p = .0001), as well as CPAP manipulation (R = 0.73, p < .0001). Arousal threshold estimates were similar using nasal pressure and pneumotachograph ventilation (R = 0.96, p < .0001). The arousal threshold in patients with OSA can be estimated using polysomnographic signals and may enable more personalized therapeutic interventions for patients with a low arousal threshold. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.
Reduced suppression of CO2-induced ventilatory stimulation by endomorphins relative to morphine.
Czapla, Marc A; Zadina, James E
2005-10-19
Opioids are among the most effective analgesics, but a major limitation for their therapeutic usefulness is their induction of respiratory depression. Endomorphin-1 (EM1), in contrast to several other mu opioids, exhibits a threshold for respiratory depression that is well above its threshold for analgesia. Its effect on sensitivity to CO(2), however, remains unknown. Minute ventilation (V(E)) in 2, 4, and 6% CO(2) was measured before and after systemic administration of EM1, endomorphin-2 (EM2), DAMGO, and morphine in the conscious rat. EM1 and EM2 attenuated the hypercapnic ventilatory response (HCVR) only in high doses, while DAMGO and morphine diminished the HCVR in much lower doses. The ventilatory effects of high doses of all 4 agonists were blocked by the mu-opioid antagonist naloxone (0.4 mg/kg i.v.), but not by the peripherally restricted mu-opioid antagonist, methyl-naloxone (0.4 mg/kg i.v.). It was concluded that the endomorphins attenuated the HCVR only in large doses, well beyond the analgesic threshold, and did so through a centrally mediated mu-opioid mechanism.
Sirsat, Tushar S; Dzialowski, Edward M
2016-04-15
Precocial birds begin embryonic life with an ectothermic metabolic phenotype and rapidly develop an endothermic phenotype after hatching. Switching to a high-energy, endothermic phenotype requires high-functioning respiratory and cardiovascular systems to deliver sufficient environmental oxygen to the tissues. We measured tidal volume (VT), breathing frequency (ƒ), minute ventilation (V̇e), and whole-animal oxygen consumption (V̇o2) in response to gradual cooling from 37.5°C (externally pipped paranates, EP) or 35°C (hatchlings) to 20°C along with response to hypercapnia during developmental transition from an ectothermic, EP paranate to endothermic hatchling. To examine potential eggshell constraints on EP ventilation, we repeated these experiments in artificially hatched early and late EP paranates. Hatchlings and artificially hatched late EP paranates were able to increase V̇o2significantly in response to cooling. EP paranates had high ƒ that decreased with cooling, coupled with an unchanging low VT and did not respond to hypercapnia. Hatchlings had significantly lower ƒ and higher VT and V̇e that increased with cooling and hypercapnia. In response to artificial hatching, all ventilation values quickly reached those of hatchlings and responded to hypercapnia. The timing of artificial hatching influenced the temperature response, with only artificially hatched late EP animals, exhibiting the hatchling ventilation response to cooling. We suggest one potential constraint on ventilatory responses of EP paranates is the rigid eggshell, limiting air sac expansion during inhalation and constraining VT Upon natural or artificial hatching, the VT limitation is removed and the animal is able to increase VT, V̇e, and thus V̇o2, and exhibit an endothermic phenotype. Copyright © 2016 the American Physiological Society.
Sirsat, Tushar S.
2016-01-01
Precocial birds begin embryonic life with an ectothermic metabolic phenotype and rapidly develop an endothermic phenotype after hatching. Switching to a high-energy, endothermic phenotype requires high-functioning respiratory and cardiovascular systems to deliver sufficient environmental oxygen to the tissues. We measured tidal volume (VT), breathing frequency (ƒ), minute ventilation (V̇e), and whole-animal oxygen consumption (V̇o2) in response to gradual cooling from 37.5°C (externally pipped paranates, EP) or 35°C (hatchlings) to 20°C along with response to hypercapnia during developmental transition from an ectothermic, EP paranate to endothermic hatchling. To examine potential eggshell constraints on EP ventilation, we repeated these experiments in artificially hatched early and late EP paranates. Hatchlings and artificially hatched late EP paranates were able to increase V̇o2 significantly in response to cooling. EP paranates had high ƒ that decreased with cooling, coupled with an unchanging low VT and did not respond to hypercapnia. Hatchlings had significantly lower ƒ and higher VT and V̇e that increased with cooling and hypercapnia. In response to artificial hatching, all ventilation values quickly reached those of hatchlings and responded to hypercapnia. The timing of artificial hatching influenced the temperature response, with only artificially hatched late EP animals, exhibiting the hatchling ventilation response to cooling. We suggest one potential constraint on ventilatory responses of EP paranates is the rigid eggshell, limiting air sac expansion during inhalation and constraining VT. Upon natural or artificial hatching, the VT limitation is removed and the animal is able to increase VT, V̇e, and thus V̇o2, and exhibit an endothermic phenotype. PMID:26818053
Müller, Jan; Hager, Alfred; Diller, Gerhard-Paul; Derrick, Graham; Buys, Roselien; Dubowy, Karl-Otto; Takken, Tim; Orwat, Stefan; Inuzuka, Ryo; Vanhees, Luc; Gatzoulis, Michael; Giardini, Alessandro
2015-10-01
Patients with repaired tetralogy of Fallot (ToF) have an increased long-term risk of cardiovascular morbidity and mortality. Risk stratification in this population is difficult. Initial evidence suggests that cardiopulmonary exercise testing (CPET) may be helpful to risk-stratify patients with repaired ToF. We studied 875 patients after surgical repair for ToF (358 females, age 25.5 ± 11.7 year, range 7-75 years) who underwent CPET between 1999 and 2009. During a mean follow-up of 4.1 ± 2.6 years after CPET, 30 patients (3.4%) died or had sustained ventricular tachycardia (VT). 225 patients (25.7%) had other cardiac related events (emergency admission, surgery, or catheter interventions). On multivariable Cox regression-analysis, %predicted peak oxygen uptake (V˙O2 %) (p=0.001), resting QRS duration (p=0.030) and age (p<0.001) emerged as independent predictors of mortality or sustained VT. Patients with a peak V˙O2 ≤ 65% of predicted and a resting QRS duration ≥ 170 ms had a 11.4-fold risk of death or sustained VT. Ventilatory efficiency expressed as V˙E/V˙CO2 slope (p<0.001), peak V˙O2 % (p=.001), QRS duration (p=.001) and age (p=0.046) independently predicted event free survival. V˙E/V˙CO2 slope ≥ 31.0, peak V˙O2 % ≤ 65% and QRS duration ≥ 170 ms were the cut-off points with best sensitivity and specificity to detect an unfavorable outcome. CPET is an important predictive tool that may assist in the risk stratification of patients with ToF. Subjects with a poor exercise capacity in addition to a prolonged QRS duration have a substantially increased risk for death or sustained ventricular tachycardia, as well as for cardiac-related hospitalizations. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Dempsey, Jerome A; Smith, Curtis A; Przybylowski, Tadeuez; Chenuel, Bruno; Xie, Ailiang; Nakayama, Hideaki; Skatrud, James B
2004-01-01
Sleep unmasks a highly sensitive hypocapnia-induced apnoeic threshold, whereby apnoea is initiated by small transient reductions in arterial CO2 pressure (PaCO2) below eupnoea and respiratory rhythm is not restored until PaCO2 has risen significantly above eupnoeic levels. We propose that the ‘CO2 reserve’ (i.e. the difference in PaCO2 between eupnoea and the apnoeic threshold (AT)), when combined with ‘plant gain’ (or the ventilatory increase required for a given reduction in PaCO2) and ‘controller gain’ (ventilatory responsiveness to CO2 above eupnoea) are the key determinants of breathing instability in sleep. The CO2 reserve varies inversely with both plant gain and the slope of the ventilatory response to reduced CO2 below eupnoea; it is highly labile in non-random eye movement (NREM) sleep. With many types of increases or decreases in background ventilatory drive and PaCO2, the slope of the ventilatory response to reduced PaCO2 below eupnoea remains unchanged from control. Thus, the CO2 reserve varies inversely with plant gain, i.e. it is widened with hyperventilation and narrowed with hypoventilation, regardless of the stimulus and whether it acts primarily at the peripheral or central chemoreceptors. However, there are notable exceptions, such as hypoxia, heart failure, or increased pulmonary vascular pressures, which all increase the slope of the CO2 response below eupnoea and narrow the CO2 reserve despite an accompanying hyperventilation and reduced plant gain. Finally, we review growing evidence that chemoreceptor-induced instability in respiratory motor output during sleep contributes significantly to the major clinical problem of cyclical obstructive sleep apnoea. PMID:15284345
Castagna, Carlo; Impellizzeri, Franco M; Chamari, Karim; Carlomagno, Domenico; Rampinini, Ermanno
2006-05-01
Yo-yo tests are very popular in soccer; however, no study has addressed details of their relation to canonical aspects of aerobic fitness. Furthermore, no information is available on the effect of the individual levels of lower limbs' explosive strength on yo-yo tests in soccer players. The purpose of this study was to examine the physiological determinants of Yo-yo Endurance Test Level 2 (YYETL2) and Yo-yo Intermittent Recovery Test Level 1 (YYIRTL1) in soccer players. Twenty-four soccer players (body mass, 74.6 +/- 8.5 kg; height, 178.1 +/- 4.5 cm; age, 25.6 +/- 5.1 years) were tested for VO2max and ventilatory threshold (VT) on a motorized treadmill. Lower-limb explosive strength was assessed using vertical countermovement jumps (CMJ) performed on a force platform. Results showed that YYETL2 and YYIRTL1 performances (m) were significantly related (r = 0.75, p = 0.00002). YYETL2 results were significantly related to VO2max, VTVO2, and speed at VT (r = 0.75, 0.76, and 0.83, respectively; p < 0.00002). Peak treadmill speed results were significantly related to YYETL2 and YYIRTL1 (r = 0.87 and 0.71, respectively; p < 0.0003). YYIRTL1 was related to CMJ peak power (r = 0.57; p = 0.003). These findings show that YYETL2 and YYIRTL1, although adopting similar starting and progression speeds, are influenced by different physiological variables. From these results, YYETL2 can be considered an aerobic fitness-related field test, whereas YYIRTL1 can be regarded as an aerobic-anaerobic, soccer-specific field test.
McCarthy, Avina; Mulligan, James; Egaña, Mikel
2016-11-01
A brief cold water immersion between 2 continuous high-intensity exercise bouts improves the performance of the latter compared with passive recovery in the heat. We investigated if this effect is apparent in normothermic conditions (∼19 °C), employing an intermittent high-intensity exercise designed to reflect the work performed at the high-intensity domain in team sports. Fifteen young active men completed 2 exhaustive cycling protocols (Ex1 and Ex2: 12 min at 85% ventilatory threshold (VT) and then an intermittent exercise alternating 30-s at 40% peak power (P peak ) and 30 s at 90% P peak to exhaustion) separated by 15 min of (i) passive rest, (ii) 5-min cold-water immersion at 8 °C, and (iii) 10-min cold-water immersion at 8 °C. Core temperature, heart rate, rates of perceived exertion, and oxygen uptake kinetics were not different during Ex1 among conditions. Time to failure during the intermittent exercise was significantly (P < 0.05) longer during Ex2 following the 5- and 10-min cold-water immersions (7.2 ± 3.5 min and 7.3 ± 3.3 min, respectively) compared with passive rest (5.8 ± 3.1 min). Core temperature, heart rate, and rates of perceived exertion were significantly (P < 0.05) lower during most periods of Ex2 after both cold-water immersions compared with passive rest. The time constant of phase II oxygen uptake response during the 85% VT bout of Ex2 was not different among the 3 conditions. A postexercise, 5- to 10-min cold-water immersion increases subsequent intermittent high-intensity exercise compared with passive rest in normothermia due, at least in part, to reductions in core temperature, circulatory strain, and effort perception.
Metabolic responses associated with deer hunting.
Peterson, A T; Steffen, J; Terry, L; Davis, J; Porcari, J P; Foster, C
1999-12-01
Deer hunting is a popular recreational activity with a high rate of cardiovascular events. Previous studies have demonstrated large HR responses during deer hunting. This study compared the HR and metabolic costs of maximal treadmill (TM) exercise with those of hiking while deer hunting and while dragging a deer. Healthy male volunteers (N = 16) performed a maximal TM exercise test, a 0.8-km hiking test, and a 0.4-km dragging test over lightly rolling terrain. VO2 was measured by portable spirometry and HR by radiotelemetry. HR averaged 74.0 +/- 7.0% and 89.1 +/- 4.5% of peak TM HR during the hike and drag, respectively. The peak HR observed during hiking and dragging was 83.2 +/- 6.0% and 94.9 +/- 4.2% of peak TM HR, respectively. VO2 averaged 62.2 +/- 15.8% and achieved a peak of 77.2 +/- 19.0% of TM VO2 while hiking. This corresponded to 86.8 +/- 17.3% and 108.1 +/- 22.3% of ventilatory threshold (VT), respectively. VO2 averaged 72.3 +/- 21.0% and achieved a peak of 91.2 +/- 21.4% of peak TM VO2 while dragging the deer. This corresponded to 101.5 +/- 27.7% and 128.5 +/- 26.8% of VT, respectively. The VO2/HR relationship showed significant (P < 0.05) difference between the dragging test and the TM test with a disproportionately high HR. The VO2/HR relationship between the hiking and TM tests was comparable. In part, the previously described large HR responses and high rate of cardiovascular complications associated with deer hunting may attributable to the elevated metabolic costs of associated activities.
Oliveira, R D; Lopes, J M; Sanches, J R; Kalinin, A L; Glass, M L; Rantin, F T
2004-12-01
The jeju, Hoplerythrinus unitaeniatus, is equipped with a modified part of the swim bladder that allows aerial respiration. On this background, we have evaluated its respiratory and cardiovascular responses to aquatic hypoxia. Its aquatic O2 uptake (V(O2)) was maintained constant down to a critical P(O2) (P(cO2)) of 40 mm Hg, below which V(O2) declined linearly with further reductions of P(iO2). Just below P(cO2), the ventilatory tidal volume (V(T)) increased significantly along with gill ventilation (V(G)), while respiratory frequency changed little. Consequently, water convection requirement (V(G)/V(O2)) increased steeply. The same threshold applied to cardiovascular responses that included reflex bradycardia and elevated arterial blood pressure (P(a)). Aerial respiration was initiated at water P(O2) of 44 mm Hg and breathing episodes and time at the surface increased linearly with more severe hypoxia. At the lowest water P(O2) (20 mm Hg), the time spent at the surface accounted for 50% of total time. This response has a character of a temporary emergency behavior that may allow the animal to escape hypoxia.
Greenstein, Yonatan Y; Shakespeare, Eric; Doelken, Peter; Mayo, Paul H
2017-07-01
Flexible bronchoscopy (FB) in intubated patients on mechanical ventilation increases airway resistance. During FB, two ventilatory strategies are possible: maintaining tidal volume (VT) while maintaining baseline CO2 or allowing reduction of VT. The former strategy carries risk of hyperinflation due to expiratory flow limitation with FB. The aim of the authors was too study end expiratory lung volume (EELV) during FB of intubated subjects while limiting VT. We studied 16 subjects who were intubated on mechanical ventilation and required FB. Changes in EELV were measured by respiratory inductance plethysmography. Ventilator mechanics, EELV, and arterial blood gases, were measured. FB insertions decreased EELV in 64% of cases (-325±371 mL) and increased it in 32% of cases (65±59 mL). Suctioning decreased EELV in 76% of cases (-120±104 mL) and increased it in 16% of cases (29±33 mL). Respiratory mechanics were unchanged. Pre-FB and post-FB, PaO2 decreased by 61±96 mm Hg and PaCO2 increased by 15±7 mm Hg. There was no clinically significant increase in EELV in any subject during FB. Decreases in EELV coincided with FB-suctioning maneuvers. Peak pressure limiting ventilation protected the subject against hyperinflation with a consequent, well-tolerated reduction in VT, and hypercapnea. Suctioning should be limited, especially in patients vulnerable to derecruitment effect.
"Optimal" application of ventilatory assist in Cheyne-Stokes respiration: a simulation study.
Khoo, M C; Benser, M E
2005-01-01
Although a variety of ventilator therapies have been employed to treat Cheyne-Stokes respiration (CSR), these modalities do not completely eliminate CSR. As well, most current strategies require that ventilatory assist be provided continuously. We used a computer model of the respiratory control system to determine whether a ventilatory assist strategy could be found that would substantially reduce the severity of CSR while minimizing the application of positive airway pressure. We assessed the effects of different levels of ventilatory assist applied during breaths that fell below selected hypopneic thresholds. These could be applied during the descending, ascending, or both phases of the CSR cycle. We found that ventilatory augmentation equal to 30-40% of eupneic drive, applied whenever ventilation fell below 70% of the eupneic level during the ascending or descending-and-ascending phases of CSR led to the greatest regularization of breathing with minimal ventilator intervention. Application of ventilatory assist during the descending phase produced little effect.
Kozian, Alf; Schilling, Thomas; Schütze, Hartmut; Senturk, Mert; Hachenberg, Thomas; Hedenstierna, Göran
2011-05-01
The increased tidal volume (V(T)) applied to the ventilated lung during one-lung ventilation (OLV) enhances cyclic alveolar recruitment and mechanical stress. It is unknown whether alveolar recruitment maneuvers (ARMs) and reduced V(T) may influence tidal recruitment and lung density. Therefore, the effects of ARM and OLV with different V(T) on pulmonary gas/tissue distribution are examined. Eight anesthetized piglets were mechanically ventilated (V(T) = 10 ml/kg). A defined ARM was applied to the whole lung (40 cm H(2)O for 10 s). Spiral computed tomographic lung scans were acquired before and after ARM. Thereafter, the lungs were separated with an endobronchial blocker. The pigs were randomized to receive OLV in the dependent lung with a V(T) of either 5 or 10 ml/kg. Computed tomography was repeated during and after OLV. The voxels were categorized by density intervals (i.e., atelectasis, poorly aerated, normally aerated, or overaerated). Tidal recruitment was defined as the addition of gas to collapsed lung regions. The dependent lung contained atelectatic (56 ± 10 ml), poorly aerated (183 ± 10 ml), and normally aerated (187 ± 29 ml) regions before ARM. After ARM, lung volume and aeration increased (426 ± 35 vs. 526 ± 69 ml). Respiratory compliance enhanced, and tidal recruitment decreased (95% vs. 79% of the whole end-expiratory lung volume). OLV with 10 ml/kg further increased aeration (atelectasis, 15 ± 2 ml; poorly aerated, 94 ± 24 ml; normally aerated, 580 ± 98 ml) and tidal recruitment (81% of the dependent lung). OLV with 5 ml/kg did not affect tidal recruitment or lung density distribution. (Data are given as mean ± SD.) The ARM improves aeration and respiratory mechanics. In contrast to OLV with high V(T), OLV with reduced V(T) does not reinforce tidal recruitment, indicating decreased mechanical stress.
Functional differences in bi-level pressure preset ventilators.
Highcock, M P; Shneerson, J M; Smith, I E
2001-02-01
The performance of four bilevel positive pressure preset ventilators was compared. The ventilators tested were; BiPAP ST30 (Respironics); Nippy2 (B + D Electrical); Quantum PSV (Healthdyne); and Sullivan VPAP H ST (Resmed). A patient simulator was used to determine the sensitivity of the triggering mechanisms and the responses to a leak within the patient circuit, and to changes in patient effort. Significant differences (p <0.05) between the devices were seen in the trigger delay time and inspiratory trigger pressure. When a leak was introduced into the patient circuit, the fall in tidal volume (VT) was less than ten per cent for each ventilator. The addition of patient effort produced a number of changes in the ventilation delivered. Patient efforts of 0.25 s induced a variable fall in VT. An increase in VT was seen with some ventilators with patient efforts of 1 s but the effect was variable. Trigger failures and subsequent falls in minute volume were seen with the BiPAP and the Nippy2 at the highest respiratory frequency. Differences in the responses of the ventilators are demonstrated that may influence the selection of a ventilator, particularly in the treatment of breathless patients with ventilatory failure.
HIIT Augments Muscle Carnosine in the Absence of Dietary Beta-Alanine Intake.
Salles Painelli, Vitor de; Nemezio, Kleiner Márcio; Jéssica, Ana; Franchi, Mariana; Andrade, Isabel; Riani, Luiz Augusto; Saunders, Bryan; Sale, Craig; Harris, Roger Charles; Gualano, Bruno; Artioli, Guilherme Giannini
2018-06-21
Cross-sectional studies suggest that training can increase muscle carnosine (MCarn), although longitudinal studies have failed to confirm this. A lack of control for dietary β-alanine intake or muscle fibre type shifting may have hampered their conclusions. The purpose of the present study was to investigate the effects of high-intensity interval training (HIIT) on MCarn. Twenty vegetarian men were randomly assigned to a control (CON; n=10) or HIIT (n=10) group. HIIT was carried out on a cycle ergometer for 12 weeks, with progressive volume (6-12 series) and intensity (140-170% lactate threshold [LT]). MCarn was quantified in whole-muscle and individual fibres; expression of selected genes (CARNS, CNDP2, ABAT, TauT and PAT1) and muscle buffering capacity in vitro (βmin vitro) were also determined. Exercise tests were performed to evaluate total work done (TWD), VO2max, ventilatory thresholds (VT) and LT. TWD, VT, LT, VO2max and βmin vitro were improved in the HIIT group (all P<0.05), but not in CON (p>0.05). MCarn (in mmol·kg dry muscle) increased in the HIIT (15.8±5.7 to 20.6±5.3; p=0.012) but not the CON group (14.3±5.3 to 15.0±4.9; p=0.99). In type I fibres, MCarn increased in the HIIT (from 14.4±5.9 to 16.8±7.6; p=0.047) but not the CON group (from 14.0±5.5 to 14.9±5.4; p=0.99). In type IIa fibres, MCarn increased in the HIIT group (from 18.8±6.1 to 20.5±6.4; p=0.067) but not the CON group (from 19.7±4.5 to 18.8±4.4; p=0.37). No changes in gene expression were shown. In the absence of any dietary intake of β-alanine, HIIT increased MCarn content. The contribution of increased MCarn to the total increase in βmin vitro appears to be small.
Pohl, A; Heuwieser, W; Burfeind, O
2014-07-01
The objective of this study was to evaluate whether milk temperature (MT) measured by automatic milking system (AMS) is a reliable indicator of body temperature of dairy cows and whether cows with fever could be detected. Data loggers (Minilog 8, Vemco Ltd., Halifax, NS, Canada) measuring body temperature were inserted for 7 ± 1 d into the vaginal cavity of 31 dairy cows and programmed to take 1 reading/min. Milk temperature was recorded at each milking event by the AMS, and values from the vaginal loggers were paired with the corresponding MT. The correlation (r) between vaginal temperature (VT) and MT was 0.52. Vaginal temperature was higher (39.1 ± 0.4°C) than MT (38.6 ± 0.7°C) with a mean difference of 0.5 ± 0.6°C. The ability of MT to identify cows with fever was assessed using 2 approaches. In the first approach, VT could indicate fever at any time of the day, whereas MT could display fever only during the milking events of a given day. Different definitions of fever based on thresholds of VT and duration exceeding these thresholds were constructed. Different thresholds of MT were tested to distinguish between cows with and without fever. The combination of 39.0°C as a threshold for MT and 39.5°C for at least 2h/d as a threshold for VT resulted in the highest combination of sensitivity (0.65) and specificity (0.65). In the second approach, we evaluated whether MT could identify cows with fever at a given milking event. A threshold of MT >38.7°C delivered the best combination of sensitivity (0.77) and specificity (0.66) when fever was defined as VT ≥39.5°C. Therefore, MT measured by AMS can be indicative of fever in dairy cows to a limited extent. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Yi; Liu, Qi; Cai, Jing; Li, Yun; Shi, Yi; Wang, Xizhang; Hu, Zheng
2014-06-01
This study investigates the remarkable reduction in the threshold voltage (VT) of pentacene-based thin film transistors with pentacene/copper phthalocyanine (CuPc) sandwich configuration. This reduction is accompanied by increased mobility and lowered sub-threshold slope (S). Sandwich devices coated with a 5 nm layer of CuPc layer are compared with conventional top-contact devices, and results indicate that VT decreased significantly from -20.4 V to -0.2 V, that mobility increased from 0.18 cm2/Vs to 0.51 cm2/Vs, and that S was reduced from 4.1 V/dec to 2.9 V/dec. However, the on/off current ratio remains at 105. This enhanced performance could be attributed to the reduction in charge trap density by the incorporated CuPc layer. Results suggest that this method is simple and effectively generates pentacene-based organic thin film transistors with high mobility and low VT.
Carroll, Michael S; Patwari, Pallavi P; Kenny, Anna S; Brogadir, Cindy D; Stewart, Tracey M; Weese-Mayer, Debra E
2015-12-01
Hypoventilation is a defining feature of Rapid-onset Obesity with Hypothalamic dysfunction, Hypoventilation and Autonomic Dysregulation (ROHHAD), a rare respiratory and autonomic disorder. This chronic hypoventilation has been explained as the result of dysfunctional chemosensory control circuits, possibly affecting peripheral afferent input, central integration, or efferent motor control. However, chemosensory function has never been quantified in a cohort of ROHHAD patients. Therefore, the purpose of this study was to assess the response to awake ventilatory challenge testing in children and adolescents with ROHHAD. The ventilatory, cardiovascular and cerebrovascular responses in 25 distinct comprehensive physiological recordings from seven unique ROHHAD patients to three different gas mixtures were analyzed at breath-to-breath and beat-to-beat resolution as absolute measures, as change from baseline, or with derived metrics. Physiologic measures were recorded during a 3-min baseline period of room air, a 3-min gas exposure (of 100% O2; 95% O2, 5% CO2; or 14% O2, 7% CO2 balanced with N2), and a 3-min recovery period. An additional hypoxic challenge was conducted which consisted of either five or seven tidal breaths of 100% N2. While ROHHAD cases showed a diminished VT and inspiratory drive response to hypoxic hypercapnia and absent behavioral awareness of the physiologic compromise, most ventilatory, cardiovascular, and cerebrovascular measures were similar to those of previously published controls using an identical protocol, suggesting a mild chemosensory deficit. Nonetheless, the high mortality rate, comorbidity and physiological fragility of patients with ROHHAD demand continued clinical vigilance. © 2015 Wiley Periodicals, Inc.
Hearing thresholds and ventilation tube treatment in children with unilateral cleft lip and palate.
Tengroth, Birgitta; Hederstierna, Christina; Neovius, Erik; Flynn, Traci
2017-06-01
Children with cleft lip and palate have a high prevalence of otitis media with effusion (OME) which is often associated with a fluctuating, conductive hearing loss in the low and mid-frequencies and a risk for permanent hearing loss in the higher frequencies. Although common, there is no consensus on the treatment of OME with ventilation tubes. The aim of this study is to document if the risk for permanent hearing loss and acquired cholesteatoma increases due to treatment with ventilation tubes (VT treatments) during childhood in a group of children with cleft lip and palate. A retrospective medical chart review of 33 children (25 boys and 8 girls) born with unilateral cleft lip and palate (UCLP) was completed. Audiological data (results of hearing sensitivity tests, the total number of hearing tests, and number of VT treatments) were extracted from medical records from when the children were 4-7 and >7-10 years of age. The hearing thresholds in the speech frequencies improved with age (p < 0,05) but a minority of the children continued to present with elevated hearing thresholds in the higher frequencies at >7-10 years of age. There were no significant correlations between number of VT treatments and hearing thresholds at >7-10 years. Four of the 33 children presented with complications: two children exhibited perforations of the ear drum (6.1%) and two children developed unilateral cholesteatoma (6.1%). In the current study, the hearing sensitivity of children with cleft lip and palate improved with age. However, this improvement was not seen in the higher frequencies. Twelve percent of the children experienced complications following VT treatments. Due to these complications, it is recommended that all children with cleft palate should have routine follow-ups by an ENT doctor and audiologist. As part of the routine follow-up care, hearing assessments should be performed before and after VT treatments. Copyright © 2017 Elsevier B.V. All rights reserved.
Effects of movement and work load in patients with congenital central hypoventilation syndrome.
Hager, Alfred; Koch, Walter; Stenzel, Heike; Hess, John; Schöber, Johannes
2007-04-01
Patients with congenital central hypoventilation syndrome lack ventilatory chemosensitivity and depend at least in part on the ergoreceptor function during exercise. In these patients a substantial increase of ventilation has been reported for passive movement during sleep as well as active movement on a treadmill. The aim of the study was to investigate ventilatory response to an increasing work load with constant movement. Eighteen patients and 17 healthy volunteers performed a cardiopulmonary exercise test on a bicycle pedaling at a constant rate of about 60 revolutions per minute throughout the entire test. The patients were able to exercise adequately and showed normal peak oxygen uptake. There was a steep rise in minute ventilation in both groups at the start of exercise, yet there was only a minor increase in both groups during the increase of workload up to the anaerobic threshold. After the anaerobic threshold, there was again an increase in ventilation in both groups, but the increase was less prominent in the patient group. Ventilation in patients with congenital central hypoventilation syndrome is increased during exercise caused both by movement (mechanoreceptors) and by anaerobic workload. This facilitates a normal ventilatory drive up to the anaerobic threshold and a normal exercise capacity in these patients.
Elbehairy, Amany F; Ciavaglia, Casey E; Webb, Katherine A; Guenette, Jordan A; Jensen, Dennis; Mourad, Sahar M; Neder, J Alberto; O'Donnell, Denis E
2015-06-15
Several studies in mild chronic obstructive pulmonary disease (COPD) have shown a higher than normal ventilatory equivalent for carbon dioxide ([Formula: see text]e/[Formula: see text]co2) during exercise. Our objective was to examine pulmonary gas exchange abnormalities and the mechanisms of high [Formula: see text]e/[Formula: see text]co2 in mild COPD and its impact on dyspnea and exercise intolerance. Twenty-two subjects (11 patients with GOLD [Global Initiative for Chronic Obstructive Lung Disease] grade 1B COPD, 11 age-matched healthy control subjects) undertook physiological testing and a symptom-limited incremental cycle exercise test with arterial blood gas collection. Patients (post-bronchodilator FEV1: 94 ± 10% predicted; mean ± SD) had evidence of peripheral airway dysfunction and reduced peak oxygen uptake compared with control subjects (80 ± 18 vs. 113 ± 24% predicted; P<0.05). Arterial blood gases were within the normal range and effective alveolar ventilation was not significantly different from control subjects throughout exercise. The alveolar-arterial O2 tension gradient was elevated at rest and throughout exercise in COPD (P<0.05). [Formula: see text]e/[Formula: see text]co2, dead space to tidal volume ratio (Vd/Vt), and arterial to end-tidal CO2 difference were all higher (P<0.05) in patients with COPD than in control subjects during exercise. In patients with COPD versus control subjects, there was significant dynamic hyperinflation and greater tidal volume constraints (P<0.05). Standardized dyspnea intensity ratings were also higher (P<0.05) in patients with COPD versus control subjects in association with higher ventilatory requirements. Within all subjects, Vd/Vt correlated with the [Formula: see text]e/[Formula: see text]co2 ratio during submaximal exercise (r=0.780, P<0.001). High Vd/Vt was the most consistent gas exchange abnormality in smokers with only mild spirometric abnormalities. Compensatory increases in minute ventilation during exercise maintained alveolar ventilation and arterial blood gas homeostasis but at the expense of earlier dynamic mechanical constraints, greater dyspnea, and exercise intolerance in mild COPD.
Boer, Pieter-Henk; Meeus, Mira; Terblanche, Elmarie; Rombaut, Lies; Wandele, Inge De; Hermans, Linda; Gysel, Tineke; Ruige, Johannes; Calders, Patrick
2014-03-01
In this study we evaluated the effect of sprint interval training on metabolic and physical fitness in adolescents and young adults with intellectual disabilities when compared with continuous aerobic training and no training (control). Fifty-four persons with intellectual disabilities (age: 17 (3.0), body mass index: 27.7 (3.7), intelligence quotient: 59 (8.6)) were matched based on age, gender and intelligence quotient between sprint interval training (n = 17), continuous aerobic training (n = 15) and control (n = 14). Sprint interval training was composed of three blocks of 10 minutes at ventilatory threshold (blocks 1 and 3: 10 sprint bouts of 15 seconds, followed by 45 seconds relative rest; block 2: continuous training) twice a week for 15 weeks. Continuous aerobic training was composed of three blocks of 10 minutes continuous training. After eight weeks, intensity was increased to 110% of ventilatory threshold. The control group did not participate in supervised exercise training. Before and after the training period, body composition, physical and metabolic fitness were evaluated. Sprint interval training showed a significant positive evolution for waist circumference, fat%, systolic blood pressure, lipid profile, fasting insulin, homeostasis model assessment of insulin resistance, peak VO2, peak Watt, ventilatory threshold, 6-minute walk distance and muscle fatigue resistance when compared with no training (P < 0.01). The sprint interval training group demonstrated significant improvements for fat%, systolic blood pressure, low-density lipoprotein, fasting insulin, peak VO2 and peak power and ventilatory threshold (P < 0.01) when compared with continuous aerobic training. In this study we could observe that sprint interval training has stronger beneficial effects on body composition, physical fitness and metabolic fitness compared with control. Compared with continuous aerobic training, sprint interval training seems to result in better outcome.
Beaudin, Andrew E; Clegg, Miriam E; Walsh, Michael L; White, Matthew D
2009-09-01
Hyperthermia-induced hyperventilation has been proposed to be a human thermolytic thermoregulatory response and to contribute to the disproportionate increase in exercise ventilation (VE) relative to metabolic needs during high-intensity exercise. In this study it was hypothesized that VE would adapt similar to human eccrine sweating (E(SW)) following a passive heat acclimation (HA). All participants performed an incremental exercise test on a cycle ergometer from rest to exhaustion before and after a 10-day passive exposure for 2 h/day to either 50 degrees C and 20% relative humidity (RH) (n = 8, Acclimation group) or 24 degrees C and 32% RH (n = 4, Control group). Attainment of HA was confirmed by a significant decrease (P = 0.025) of the esophageal temperature (T(es)) threshold for the onset of E(SW) and a significantly elevated E(SW) (P < or = 0.040) during the post-HA exercise tests. HA also gave a significant decrease in resting T(es) (P = 0.006) and a significant increase in plasma volume (P = 0.005). Ventilatory adaptations during exercise tests following HA included significantly decreased T(es) thresholds (P < or = 0.005) for the onset of increases in the ventilatory equivalents for O(2) (VE/VO(2)) and CO(2) (VE/VCO(2)) and a significantly increased VE (P < or = 0.017) at all levels of T(es). Elevated VE was a function of a significantly greater tidal volume (P = 0.003) at lower T(es) and of breathing frequency (P < or = 0.005) at higher T(es). Following HA, the ventilatory threshold was uninfluenced and the relationships between VO(2) and either VE/VO(2) or VE/VCO(2) did not explain the resulting hyperventilation. In conclusion, the results support that exercise VE following passive HA responds similarly to E(SW), and the mechanism accounting for this adaptation is independent of changes of the ventilatory threshold or relationships between VO(2) with each of VE/VO(2) and VE/VCO(2).
Changes in respiratory control after three hours of isocapnic hypoxia in humans
Mahamed, Safraaz; Cunningham, David A; Duffin, James
2003-01-01
Despite the obvious role of hypoxia in eliciting respiratory acclimatisation in humans, the function of the peripheral chemoreflex is uncertain. We investigated this uncertainty using 3 h of isocapnic hypoxia as a stimulus (end-tidal PCO2, 0.5–1.0 mmHg above eucapnia; end-tidal PO2, 50 mmHg), hypothesising that this stimulus would induce an enhancement of the peripheral chemoreflex ventilatory response to hypoxia. Current evidence conflicts as to whether this enhancement is mediated by an increase in the sensitivity or a decrease in the threshold of the peripheral chemoreflex ventilatory response to carbon dioxide. Employing a modified rebreathing technique to assess chemoreflex function, we found evidence of the latter in nine healthy volunteers (six male, three female). Testing consisted of pairs of isoxic rebreathing tests at high and low levels of oxygen, performed before, immediately after and 1 h after a 3 h isocapnic hypoxic exposure. No parameters changed significantly in the high-oxygen rebreathing tests. In the low-oxygen rebreathing tests there were no changes in non-chemoreflex ventilatory drives, or in the sensitivity to carbon dioxide, but the carbon dioxide response threshold decreased (≈1.5 mmHg) immediately after exposure, and the decrease persisted for 1 h (one-way repeated-measures ANOVA; P < 0.05). We repeated the protocol in five of the original nine volunteers, but this time exposing them to isocapnic normoxia. No trends or significant changes were observed in any of the rebreathing test parameters. These findings demonstrate that in the earliest stages of acclimatisation, there is a decrease in the threshold of the peripheral chemoreflex response to carbon dioxide, which persists for at least 1 h after the return to normoxia. We suggest that ventilatory acclimatisation to hypoxia results from this decreased threshold, reflecting an increase in the activity of the peripheral chemoreflex. PMID:12562969
Cardiopulmonary Exercise Testing in Adult Congenital Heart Disease.
Mantegazza, Valentina; Apostolo, Anna; Hager, Alfred
2017-07-01
Recently, the number of patients with congenital heart diseases reaching adulthood has been progressively increasing in developed countries, and new issues are emerging: the evaluation of their capacity to cope with physical activity and whether this knowledge can be used to optimize medical management. A symptom-limited cardiopulmonary exercise test has proven to be an essential tool, because it can objectively evaluate the functional cardiovascular capacity of these patients, identify the pathological mechanisms of the defect (circulatory failure, shunts, and/or pulmonary hypertension), and help prescribe an individualized rehabilitation program when needed. The common findings on cardiopulmonary exercise testing in patients with congenital heart diseases are a reduced peak [Formula: see text]o 2 , an early anaerobic threshold, a blunted heart rate response, a reduced increase of Vt, and an increased [Formula: see text]e/[Formula: see text]co 2 . All these measures suggest common pathophysiological abnormalities: (1) a compromised exercise capacity from anomalies affecting the heart, vessels, lungs, or muscles; (2) chronotropic incompetence secondary to cardiac autonomic dysfunction or β-blockers and antiarrhythmic therapy; and (3) ventilatory inefficiency caused by left-heart failure with pulmonary congestion, pulmonary hypertension, pulmonary obstructive vascular disease, or cachexia. Most of these variables also have prognostic significance. For these patients, cardiopulmonary exercise testing allows evaluation and decisions affecting lifestyle and therapeutic interventions.
Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?
Chow, Lily C; Vanderhal, Andre; Raber, Jorge; Sola, Augusto
2002-09-01
Bedside pulmonary mechanics monitors (PMM) have become useful in ventilatory management in neonates. These monitors are used more frequently due to recent improvements in data-processing capabilities. PMM devices are often part of the ventilator or are separate units. The accuracy and reliability of these systems have not been carefully evaluated. We compared a single ventilatory parameter, tidal volume (V(t)), as measured by several systems. We looked at two freestanding PMMs: the Ventrak Respiratory Monitoring System (Novametrix, Wallingford, CT) and the Bicore CP-100 Neonatal Pulmonary Monitor (Allied Health Care Products, Riverside, CA), and three ventilators with built-in PMM: the VIP Bird Ventilator (Bird Products Corp., Palm Springs, CA), Siemens Servo 300A (Siemens-Elema AB, Solna, Sweden), and Drager Babylog 8000 (Drager, Inc., Chantilly, VA). A calibrated syringe (Hans Rudolph, Inc., Kansas City, MO) was used to deliver tidal volumes of 4, 10, and 20 mL to each ventilator system coupled with a freestanding PMM. After achieving steady state, six consecutive V(t) readings were taken simultaneously from the freestanding PMM and each ventilator. In a second portion of the bench study, we used pressure-control ventilation and measured exhaled tidal volume (V(te)) while ventilating a Bear Test Lung with the same three ventilators. We adjusted peak inspiratory pressure (PIP) under controlled conditions to achieve the three different targeted tidal volumes on the paired freestanding PMM. Again, six V(te) measurements were recorded for each tidal volume. Means and standard deviations were calculated.The percentage difference in measurement of V(t) delivered by calibrated syringe varied greatly, with the greatest discrepancy seen in the smallest tidal volumes, by up to 28%. In pressure control mode, V(te) as measured by the Siemens was significantly overestimated by 20-95%, with the biggest discrepancy at the smallest V(te), particularly when paired with the Bicore PMM. V(te), as measured by the VIP Bird and Drager paired with the Ventrak PMM, had a tendency to underestimate V(t) by up to 25% at the smallest V(te). However, when paired with the Bicore PMM, these same two ventilators read over target by up to 18%. Under controlled laboratory conditions, we demonstrated that true delivered V(te), as measured by the three ventilators and two freestanding PMM, differed markedly. In general, decreasing dynamic compliance of the tubing was not associated with greater inaccuracy in V(te) measurements. Copyright 2002 Wiley-Liss, Inc.
Vucetić, Vlatko; Sentija, Davor; Sporis, Goran; Trajković, Nebojsa; Milanović, Zoran
2014-06-01
The purpose of this study was to compare two methods for determination of anaerobic threshold from two different treadmill protocols. Forty-eight Croatian runners of national rank (ten sprinters, fifteen 400-m runners, ten middle distance runners and thirteen long distance runners), mean age 21.7 +/- 5.1 years, participated in the study. They performed two graded maximal exercise tests on a treadmill, a standard ramp treadmill test (T(SR), speed increments of 1 km x h(-1) every 60 seconds) and a fast ramp treadmill test (T(FR), speed increments of 1 km x h(-1) every 30 seconds) to determine and compare the parameters at peak values and at heart rate at the deflection point (HR(DP)) and ventilation threshold (VT). There were no significant differences between protocols (p > 0.05) for peak values of oxygen uptake (VO(2max), 4.48 +/- 0.43 and 4.44 +/- 0.45 L x min(-1)), weight related VO(2max) (62.5 +/- 6.2 and 62.0 +/- 6.0 mL x kg(-1) x min(-1)), pulmonary ventilation (VE(max), 163.1 +/- 18.7 and 161.3 +/- 19.9 L x min(-1)) and heart rate (HR(max), 192.3 +/- 8.5 and 194.4 +/- 8.7 bpm) (T(FR) and T(SR), respectively). Moreover, no significant differences between T(FR) and T(SR) where found for VT and HR(DP) when expressed as VO2 and HR. However, there was a significant effect of ramp slope on running speed at VO(2max) and at the anaerobic threshold (AnT), independent of the method used (VT: 16.0 +/- 2.2 vs 14.9 +/- 2.2 km x h(-1);HR(DP): 16.5 +/- 1.9 vs 14.9 +/- 2.0 km x h(-1) for T(FR) and T(SR) respectively). Linear regression analysis revealed high between-test and between-method correlations for VO2, HR and running speed parameters (r = 0.78-0.89, p < 0.01). The present study has indicated that the VT and HR(DP) for running (VO2, ventilation, and heart rate at VT/HR(DP)) are independent of test protocol, while there is a significant effect of ramp slope on VT and HR(DP) when expressed as running speed. Moreover, this study demonstrates that the point of deflection from linearity of heart rate may be an accurate predictor of the anaerobic threshold in trained runners, independently of the protocol used.
Haemodynamics, dyspnoea, and pulmonary reserve in heart failure with preserved ejection fraction.
Obokata, Masaru; Olson, Thomas P; Reddy, Yogesh N V; Melenovsky, Vojtech; Kane, Garvan C; Borlaug, Barry A
2018-05-19
Increases in left ventricular filling pressure are a fundamental haemodynamic abnormality in heart failure with preserved ejection fraction (HFpEF). However, very little is known regarding how elevated filling pressures cause pulmonary abnormalities or symptoms of dyspnoea. We sought to determine the relationships between simultaneously measured central haemodynamics, symptoms, and lung ventilatory and gas exchange abnormalities during exercise in HFpEF. Subjects with invasively-proven HFpEF (n = 50) and non-cardiac causes of dyspnoea (controls, n = 24) underwent cardiac catheterization at rest and during exercise with simultaneous expired gas analysis. During submaximal (20 W) exercise, subjects with HFpEF displayed higher pulmonary capillary wedge pressures (PCWP) and pulmonary artery pressures, higher Borg perceived dyspnoea scores, and increased ventilatory drive and respiratory rate. At peak exercise, ventilation reserve was reduced in HFpEF compared with controls, with greater dead space ventilation (higher VD/VT). Increasing exercise PCWP was directly correlated with higher perceived dyspnoea scores, lower peak exercise capacity, greater ventilatory drive, worse New York Heart Association (NYHA) functional class, and impaired pulmonary ventilation reserve. This study provides the first evidence linking altered exercise haemodynamics to pulmonary abnormalities and symptoms of dyspnoea in patients with HFpEF. Further study is required to identify the mechanisms by which haemodynamic derangements affect lung function and symptoms and to test novel therapies targeting exercise haemodynamics in HFpEF.
Ventilatory responses to exercise training in obese adolescents.
Mendelson, Monique; Michallet, Anne-Sophie; Estève, François; Perrin, Claudine; Levy, Patrick; Wuyam, Bernard; Flore, Patrice
2012-10-15
The aim of this study was to examine ventilatory responses to training in obese adolescents. We assessed body composition, pulmonary function and ventilatory responses (among which expiratory flow limitation and operational lung volumes) during progressive cycling exercise in 16 obese adolescents (OB) before and after 12 weeks of exercise training and in 16 normal-weight volunteers. As expected, obese adolescents' resting expiratory reserve volume was lower and inversely correlated with thoraco-abdominal fat mass (r = -0.74, p<0.0001). OB presented lower end expiratory (EELV) and end inspiratory lung volumes (EILV) at rest and during submaximal exercise, and modest expiratory flow limitation. After training, OB increased maximal aerobic performance (+19%) and maximal inspiratory pressure (93.7±31.4 vs. 81.9±28.2 cm H2O, +14%) despite lack of decrease in trunk fat and body weight. Furthermore, EELV and EILV were greater during submaximal exercise (+11% and +9% in EELV and EILV, respectively), expiratory flow limitation delayed but was not accompanied by increased V(T). However, submaximal exertional symptoms (dyspnea and leg discomfort) were significantly decreased (-71.3% and -70.7%, respectively). Our results suggest that exercise training can improve pulmonary function at rest (static inspiratory muscle strength) and exercise (greater operating lung volumes and delayed expiratory flow limitation) but these modifications did not entirely account for improved dyspnea and exercise performance in obese adolescents. Copyright © 2012 Elsevier B.V. All rights reserved.
Roy, Shreyas; Sadowitz, Benjamin; Andrews, Penny; Gatto, Louis; Marx, William; Ge, Lin; Wang, Guirong; Lin, Xin; Dean, David A.; Kuhn, Michael; Ghosh, Auyon; Satalin, Joshua; Snyder, Kathy; Vodovotz, Yoram; Nieman, Gary; Habashi, Nader
2012-01-01
Background Established ARDS is often refractory to treatment. Clinical trials have demonstrated modest treatment effects, and mortality remains high. Ventilator strategies must be developed to prevent ARDS. Hypothesis Early ventilatory intervention will block progression to ARDS if the ventilator mode: 1) maintains alveolar stability and 2) reduces pulmonary edema formation. Methods Yorkshire Pigs (38–45kg) were anaesthetized and subjected to "2-hit" Ischemia-Reperfusion and Peritoneal Sepsis. Following injury, animals were randomized into two groups: Early Preventative Ventilation (Airway Pressure Release Ventilation- APRV) vs. Non-Preventative Ventilation (NPV) and followed for 48hr. All animals received anesthesia, antibiotics, and fluid/vasopressor therapy per Surviving Sepsis Campaign. Ventilation parameters: 1) NPV Group - Tidal volume (Vt): 10cc/kg + PEEP- 5 cm/H2O volume-cycled mode, 2) APRV Group - Vt: 10–15 cc/kg; Phigh, Plow, Thigh, Tlow were titrated for optimal alveolar stability. Physiologic data and plasma were collected throughout the 48hr study period, followed by BAL and necropsy. Results APRV prevented development of ARDS (p<0.001 vs NPV) by PaO2/FiO2 ratio. Quantitative histological scoring showed APRV prevented lung tissue injury (p<0.001 vs. NPV). BALF showed APRV lowered total protein and IL-6, while preserving surfactant proteins A & B (p<0.05 vs. NPV). APRV significantly lowered lung water (p<0.001 vs. NPV). Plasma IL-6 concentrations were similar between groups. Conclusions Early preventative mechanical ventilation with APRV blocked ARDS development, preserved surfactant proteins, and reduced pulmonary inflammation and edema, despite systemic inflammation similar to NPV. These data suggest early preventative ventilation strategies stabilizing alveoli and reducing pulmonary edema can attenuate ARDS after ischemia-reperfusion-sepsis. PMID:22846945
Smith, Darren A; Saranga, Jacob; Pritchard, Andrew; Kommatas, Nikolaos A; Punnoose, Shinu Kovelal; Kale, Supriya Tukaram
2018-01-01
Mulligan's mobilisation-with-movement (MWM) techniques are proposed to achieve their clinical benefit via neurophysiological mechanisms. However, previous research has focussed on responses in the sympathetic nervous system only, and is not conclusive. An alternative measure of neurophysiological response to MWM is required to support or refute this mechanism of action. Recently, vibration threshold (VT) has been used to quantify changes in the sensory nervous system in patients experiencing musculoskeletal pain. To investigate the effect of a lateral glide MWM of the hip joint on vibration threshold compared to a placebo and control condition in asymptomatic volunteers. Fifteen asymptomatic volunteers participated in this single-blinded, randomised, within-subject, placebo, control design. Participants received each of three interventions in a randomised order; a lateral glide MWM of the hip joint into flexion, a placebo MWM, and a control intervention. Vibration threshold (VT) measures were taken at baseline and immediately after each intervention. Mean change in VT from baseline was calculated for each intervention and then analysed for between group differences using a one-way analysis of variance (ANOVA). A one-way ANOVA revealed no statistically significant differences between the three experimental conditions (P = 0.812). This small study found that a lateral glide MWM of the hip did not significantly change vibration threshold compared to a placebo and control intervention in an asymptomatic population. This study provides a method of using vibration threshold to investigate the potential neurophysiological effects of a manual therapy intervention that should be repeated in a larger, symptomatic population. Copyright © 2016 Elsevier Ltd. All rights reserved.
Fabre, Claudine; Chehere, Baptiste; Bart, Frédéric; Mucci, Patrick; Wallaert, Benoit; Grosbois, Jean Marie
2017-01-01
It has been scientifically proven that pulmonary rehabilitation improves exercise tolerance and facilitates the carrying out of daily physical activities. To optimize the physical and physiological benefits, it is necessary to individualize the training intensity for each patient. The aim of this study is to compare the heart rate (HR) responses to three exercise modalities measuring aerobic fitness in chronic obstructive pulmonary disease patients, in order to easily prescribe individual target HRs for endurance training. Fifty COPD patients (mean age: 60.1±8.5 years) were included in the study. Each patient carried out a cardiopulmonary exercise test, a 6-minute walk test (6MWT) and a 6-minute stepper test (6MST). During these tests, HR was recorded continuously. After the cardiopulmonary exercise test, the HR was noted at the ventilatory threshold (VT) and at the end of the two exercise field tests (6MWT peak and 6MST peak ). The values of the HR during the last 3 minutes of both field tests were averaged (6MWT 456 and 6MST 456 ). Finally, the HR at 60% of the HR reserve was calculated with the values of the HR measured during 6MWT and 6MST (HRr 60%walk , HRr 60%step ). The HRs measured during the 6MST were significantly higher than those measured during the 6MWT. The HRr 60%step was not significantly different from 6MWT 456 and 6MWT peak HR ( P =0.51; P =0.48). A significant correlation was observed between 6MWT 456 and 6MWT peak ( r =0.58). The 6MWT 456 and 6MWT peak HR were correlated with HRr 60%step ( r =0.68 and r =0.62). The VT could be determined in 28 patients. The HR VT was not different from 6MWT 456 , 6MWT peak , and HRr 60%step ( P =0.57, P =0.41 and P =0.88) and was correlated to 6MWT 456 , 6MWT peak , and HRr 60%step ( r =0.45, r =0.40, r =0.48). An individualized target HR for endurance training can be prescribed from the HR measured during routine tests, such as 6MWT or 6MST.
NASA Astrophysics Data System (ADS)
Ho, Ching-Yuan; Chang, Yaw-Jen
2016-02-01
Both aluminum (Al) and copper (Cu), acting as transmission lines in the hydrogenated amorphous silicon of a thin film transistor (a-Si:H TFT), were studied to investigate electrical degradation including electron-migration (EM) and threshold voltage (Vt) stability and recovery performance. Under long-term current stress, the Cu material exhibited excellent resistance to EM properties, but a passivated SiNx crack was observed due to fast heat conductivity. By applying electrical stress on the gate and drain for 5 × 104 s, the power-law time dependency of the threshold voltage shift (ΔVt) indicated that the defective state creation dominated the TFT device's instability. The presence of drain stress increased the overall ΔVt because the high longitudinal field induced impact ionization and then, enhanced hot-carrier-induced electron trapping within the gate SiNx dielectric. An annealing effect prompted a stressed a-Si:H TFT back to virgin status. This study proposes better ΔVt stability and excellent resistance against electron-migration in a Cu gate device which can be considered as a candidate for a transmission line on prolonged TFT applications.
Effects of dominant somatotype on aerobic capacity trainability
Chaouachi, M; Chaouachi, A; Chamari, K; Chtara, M; Feki, Y; Amri, M; Trudeau, F
2005-01-01
Purpose: This study examined the association between dominant somatotype and the effect on aerobic capacity variables of individualised aerobic interval training. Methods: Forty one white North African subjects (age 21.4±1.3 years; V·o2max = 52.8±5.7 ml kg–1 min–1) performed three exercise tests 1 week apart (i) an incremental test on a cycle ergometer to determine V·o2max and V·o2 at the second ventilatory threshold (VT2); (ii) a VAM-EVAL track test to determine maximal aerobic speed (vV·o2max); and (iii) an exhaustive constant velocity test to determine time limit performed at 100% vV·o2max (tlim100). Subjects were divided into four somatometric groups: endomorphs-mesomorphs (Endo-meso; n = 9), mesomorphs (Meso; n = 11), mesomorphs-ectomorphs (Meso-ecto; n = 12), and ectomorphs (Ecto; n = 9). Subjects followed a 12 week training program (two sessions/week). Each endurance training session consisted of the maximal number of successive fractions for each subject. Each fraction consisted of one period of exercise at 100% of vV·o2max and one of active recovery at 60% of vV·o2max. The duration of each period was equal to half the individual tlim100 duration (153.6±39.7 s). After the training program, all subjects were re-evaluated for comparison with pre-test results. Results: Pre- and post-training data were grouped by dominant somatotype. Two way ANOVA revealed significant somatotype-aerobic training interaction effects (p<0.001) for improvements in vV·o2max, V·o2max expressed classically and according to allometric scaling, and V·o2 at VT2. There were significant differences among groups post-training: the Meso-ecto and the Meso groups showed the greatest improvements in aerobic capacity. Conclusion: The significant somatotype-aerobic training interaction suggests different trainability with intermittent and individualised aerobic training according to somatotype. PMID:16306506
Cardiorespiratory Coordination in Repeated Maximal Exercise
Garcia-Retortillo, Sergi; Javierre, Casimiro; Hristovski, Robert; Ventura, Josep L.; Balagué, Natàlia
2017-01-01
Increases in cardiorespiratory coordination (CRC) after training with no differences in performance and physiological variables have recently been reported using a principal component analysis approach. However, no research has yet evaluated the short-term effects of exercise on CRC. The aim of this study was to delineate the behavior of CRC under different physiological initial conditions produced by repeated maximal exercises. Fifteen participants performed 2 consecutive graded and maximal cycling tests. Test 1 was performed without any previous exercise, and Test 2 6 min after Test 1. Both tests started at 0 W and the workload was increased by 25 W/min in males and 20 W/min in females, until they were not able to maintain the prescribed cycling frequency of 70 rpm for more than 5 consecutive seconds. A principal component (PC) analysis of selected cardiovascular and cardiorespiratory variables (expired fraction of O2, expired fraction of CO2, ventilation, systolic blood pressure, diastolic blood pressure, and heart rate) was performed to evaluate the CRC defined by the number of PCs in both tests. In order to quantify the degree of coordination, the information entropy was calculated and the eigenvalues of the first PC (PC1) were compared between tests. Although no significant differences were found between the tests with respect to the performed maximal workload (Wmax), maximal oxygen consumption (VO2 max), or ventilatory threshold (VT), an increase in the number of PCs and/or a decrease of eigenvalues of PC1 (t = 2.95; p = 0.01; d = 1.08) was found in Test 2 compared to Test 1. Moreover, entropy was significantly higher (Z = 2.33; p = 0.02; d = 1.43) in the last test. In conclusion, despite the fact that no significant differences were observed in the conventionally explored maximal performance and physiological variables (Wmax, VO2 max, and VT) between tests, a reduction of CRC was observed in Test 2. These results emphasize the interest of CRC evaluation in the assessment and interpretation of cardiorespiratory exercise testing. PMID:28638349
Brun, J-F; Bordenave, S; Mercier, J; Jaussent, A; Picot, M-C; Préfaut, C
2008-06-01
We evaluated the effects of targeted, moderate endurance training on healthcare cost, body composition and fitness in type 2 diabetes patients routinely followed within the French healthcare system. A total of 25 type 2 diabetic patients was randomly assigned to one of two groups: 13 underwent a training programme (eight sessions, followed by training twice a week for 30-45 minutes at home at the level of the ventilatory threshold [V(T)]); and 12 received their usual routine treatment. Both groups were followed for one year to evaluate healthcare costs, exercise effectiveness and a six-minute walking test. The training prevented loss of maximum aerobic capacity, which decreased slightly in the untrained group (P=0.014), and resulted in a higher maximum power output (P=0.041) and six-minute walking distance (P=0.020). The Voorrips activity score correlated with both V(O2max) (r=0.422, P<0.05) and six-minute walking distance (r=0.446, P<0.05). Changes in V(O2max) were negatively correlated with changes in body weight (r=0.608, P<0.01). Training decreased the insulin-resistance index (HOMA-IR) by 26% (P<0.05). Changes in percentages of fat were correlated to changes in waist circumference (r=0.436, P<0.05). The total healthcare cost was reduced by 50% in the trained group (euro 1.65+/-1 per day versus euro 3.00+/-1.47 per day in the untrained group; P<0.02) due to fewer hospitalizations (P=0.05) and less use of sulphonylureas (P<0.05). Endurance training at V(T) level prevented the decline in aerobic working capacity seen in untrained diabetics over the study period, and resulted in a marked reduction in healthcare costs due to less treatments and fewer hospitalizations.
Effects of dominant somatotype on aerobic capacity trainability.
Chaouachi, M; Chaouachi, A; Chamari, K; Chtara, M; Feki, Y; Amri, M; Trudeau, F
2005-12-01
This study examined the association between dominant somatotype and the effect on aerobic capacity variables of individualised aerobic interval training. Forty one white North African subjects (age 21.4+/-1.3 years; Vo2max = 52.8+/-5.7 ml kg(-1) min(-1)) performed three exercise tests 1 week apart (i) an incremental test on a cycle ergometer to determine Vo2max and Vo2 at the second ventilatory threshold (VT2); (ii) a VAM-EVAL track test to determine maximal aerobic speed (vVo2max); and (iii) an exhaustive constant velocity test to determine time limit performed at 100% vVo2max (tlim100). Subjects were divided into four somatometric groups: endomorphs-mesomorphs (Endo-meso; n = 9), mesomorphs (Meso; n = 11), mesomorphs-ectomorphs (Meso-ecto; n = 12), and ectomorphs (Ecto; n = 9). Subjects followed a 12 week training program (two sessions/week). Each endurance training session consisted of the maximal number of successive fractions for each subject. Each fraction consisted of one period of exercise at 100% of vVo2max and one of active recovery at 60% of vVo2max. The duration of each period was equal to half the individual tlim100 duration (153.6+/-39.7 s). After the training program, all subjects were re-evaluated for comparison with pre-test results. Pre- and post-training data were grouped by dominant somatotype. Two way ANOVA revealed significant somatotype-aerobic training interaction effects (p<0.001) for improvements in vVo2max, Vo2max expressed classically and according to allometric scaling, and Vo2 at VT2. There were significant differences among groups post-training: the Meso-ecto and the Meso groups showed the greatest improvements in aerobic capacity. The significant somatotype-aerobic training interaction suggests different trainability with intermittent and individualised aerobic training according to somatotype.
Peiffer, Jeremiah; Abbiss, Chris R; Sultana, Frederic; Bernard, Thierry; Brisswalter, Jeanick
2016-01-01
Locomotive efficiency is cited as an important component to endurance performance; however, inconsistent observations of age-related changes in efficiency question its influence in the performance of masters athletes. This study examined locomotive efficiency in young and masters triathletes during both a run and cycle test. Twenty young (28.5 ± 2.6 years) and 20 masters (59.8 ± 1.3 years) triathletes completed an incremental cycling and running test to determine maximal aerobic consumption (VO2max) and the first ventilatory threshold (VT1). Participants then completed 10-min submaximal running and cycling tests at VT1 during which locomotive efficiency was calculated from expired ventilation. Additionally, body fat percentage was determined using skin-fold assessment. During the cycle and run, VO2max was lower in the masters (48.3 ± 5.4 and 49.6 ± 4.8 ml kg(-1) min(-1), respectively) compared with young (61.6 ± 5.7 and 62.4 ± 5.2 ml kg(-1) min(-1), respectively) cohort. Maximal running speed and the cycling power output corresponding to VO2max were also lower in the masters (15.1 ± 0.8 km h(-1) and 318.6 ± 26.0 W) compared with the young (19.5 ± 1.3 km h(-1) and 383.6 ± 35.0 W) cohort. Cycling efficiency was lower (-11.2%) in the masters compared with young cohort. Similar results were observed for the energy cost of running (+10.8%); however, when scaled to lean body mass, changes were more pronounced during the run (+22.1%). Within trained triathletes, ageing can influence efficiency in both the run and cycle discipline. While disregarded in the past, efficiency should be considered in research examining performance in ageing athletes.
Foster, Carl; Farland, Courtney V.; Guidotti, Flavia; Harbin, Michelle; Roberts, Brianna; Schuette, Jeff; Tuuri, Andrew; Doberstein, Scott T.; Porcari, John P.
2015-01-01
High intensity interval training (HIIT) has become an increasingly popular form of exercise due to its potentially large effects on exercise capacity and small time requirement. This study compared the effects of two HIIT protocols vs steady-state training on aerobic and anaerobic capacity following 8-weeks of training. Fifty-five untrained college-aged subjects were randomly assigned to three training groups (3x weekly). Steady-state (n = 19) exercised (cycle ergometer) 20 minutes at 90% of ventilatory threshold (VT). Tabata (n = 21) completed eight intervals of 20s at 170% VO2max/10s rest. Meyer (n = 15) completed 13 sets of 30s (20 min) @ 100% PVO2 max/ 60s recovery, average PO = 90% VT. Each subject did 24 training sessions during 8 weeks. Results: There were significant (p < 0.05) increases in VO2max (+19, +18 and +18%) and PPO (+17, +24 and +14%) for each training group, as well as significant increases in peak (+8, + 9 and +5%) & mean (+4, +7 and +6%) power during Wingate testing, but no significant differences between groups. Measures of the enjoyment of the training program indicated that the Tabata protocol was significantly less enjoyable (p < 0.05) than the steady state and Meyer protocols, and that the enjoyment of all protocols declined (p < 0.05) across the duration of the study. The results suggest that although HIIT protocols are time efficient, they are not superior to conventional exercise training in sedentary young adults. Key points Steady state training equivalent to HIIT in untrained students Mild interval training presents very similar physiologic challenge compared to steady state training HIIT (particularly very high intensity variants were less enjoyable than steady state or mild interval training Enjoyment of training decreases across the course of an 8 week experimental training program PMID:26664271
Foster, Carl; Farland, Courtney V; Guidotti, Flavia; Harbin, Michelle; Roberts, Brianna; Schuette, Jeff; Tuuri, Andrew; Doberstein, Scott T; Porcari, John P
2015-12-01
High intensity interval training (HIIT) has become an increasingly popular form of exercise due to its potentially large effects on exercise capacity and small time requirement. This study compared the effects of two HIIT protocols vs steady-state training on aerobic and anaerobic capacity following 8-weeks of training. Fifty-five untrained college-aged subjects were randomly assigned to three training groups (3x weekly). Steady-state (n = 19) exercised (cycle ergometer) 20 minutes at 90% of ventilatory threshold (VT). Tabata (n = 21) completed eight intervals of 20s at 170% VO2max/10s rest. Meyer (n = 15) completed 13 sets of 30s (20 min) @ 100% PVO2 max/ 60s recovery, average PO = 90% VT. Each subject did 24 training sessions during 8 weeks. There were significant (p < 0.05) increases in VO2max (+19, +18 and +18%) and PPO (+17, +24 and +14%) for each training group, as well as significant increases in peak (+8, + 9 and +5%) & mean (+4, +7 and +6%) power during Wingate testing, but no significant differences between groups. Measures of the enjoyment of the training program indicated that the Tabata protocol was significantly less enjoyable (p < 0.05) than the steady state and Meyer protocols, and that the enjoyment of all protocols declined (p < 0.05) across the duration of the study. The results suggest that although HIIT protocols are time efficient, they are not superior to conventional exercise training in sedentary young adults. Key pointsSteady state training equivalent to HIIT in untrained studentsMild interval training presents very similar physiologic challenge compared to steady state trainingHIIT (particularly very high intensity variants were less enjoyable than steady state or mild interval trainingEnjoyment of training decreases across the course of an 8 week experimental training program.
Effect of tracheostomy tube on work of breathing: Comparison of pre- and post-decannulation.
Villalba, Darío; Feld, Viviana; Leiva, Valeria; Scrigna, Mariana; Distéfano, Eduardo; Pratto, Romina; Rodriguez, Matías; Collins, Jesica; Rocco, Ana; Matesa, Amelia; Rossi, Damián; Areas, Laura; Virgilio, Sacha; Golfarini, Nicolás; Gil-Rosetti, Gregorio; Diaz-Ballve, Pablo; Planells, Fernando
2016-01-01
To describe and compare the work of breathing (WOB) during spontaneous breathing under four conditions: (1) breathing through a tracheostomy tube with an inflated cuff, (2) breathing through the upper airway (UA) with a deflated cuff and occluded tube, (3) breathing through the UA with an occluded cuffless tube, and (4) postdecannulation. Patients who tolerated an occluded cuffless tube were included. Ventilatory variables and esophageal pressure were recorded. The pressure-time product (PTP), PTP/min, and PTP/min/tidal volume (PTP/min/VT) were measured. Each condition was measured for 5 min with a 15 min time interval between evaluations. Quantitative data are expressed as mean ± standard deviation. Single-factor analysis of variance was used, and the Games-Howell test was used for post hoc analysis of comparisons between group means ( P ≤ 0.05). Eight patients were studied under each of the four conditions described above. Statistically significant differences were found for PTP, PTP/min, and PTP/min/VT. In the post hoc analysis for PTP, significant differences among all conditions were found. For PTP/min, there was no significant difference between Conditions 2 and 4 ( P = 0.138), and for PTP/min/VT, there was no significant difference between Conditions 1 and 2 ( P = 0.072) or between Conditions 2 and 3 ( P = 0.106). A trend toward a higher PTP, PTP/min, and PTP/min/VT was observed when breathing through a cuffless tracheostomy tube. The four conditions differed with respect to WOB. Cuff inflation could result in a reduced WOB because there is less dead space. Cuffless tracheostomy tubes generate increased WOB, perhaps due to the material deformity caused by body temperature.
Stable indium oxide thin-film transistors with fast threshold voltage recovery
NASA Astrophysics Data System (ADS)
Vygranenko, Yuriy; Wang, Kai; Nathan, Arokia
2007-12-01
Stable thin-film transistors (TFTs) with semiconducting indium oxide channel and silicon dioxide gate dielectric were fabricated by reactive ion beam assisted evaporation and plasma-enhanced chemical vapor deposition. The field-effect mobility is 3.3cm2/Vs, along with an on/off current ratio of 106, and subthreshold slope of 0.5V/decade. When subject to long-term gate bias stress, the TFTs show fast recovery of the threshold voltage (VT) when relaxed without annealing, suggesting that charge trapping at the interface and/or in the bulk gate dielectric to be the dominant mechanism underlying VT instability. Device performance and stability make indium oxide TFTs promising for display applications.
Brisswalter, Jeanick; Bouhlel, Ezzedine; Falola, Jean Marie; Abbiss, Christopher R; Vallier, Jean Marc; Hausswirth, Christophe; Hauswirth, Christophe
2011-09-01
To assess whether Ramadan intermittent fasting (RIF) affects 5000-m running performance and physiological parameters classically associated with middle-distance performance. Two experimental groups (Ramadan fasting, n = 9, vs control, n = 9) participated in 2 experimental sessions, one before RIF and the other at the last week of fasting. For each session, subjects completed 4 tests in the same order: a maximal running test, a maximal voluntary contraction (MVC) of knee extensor, 2 rectangular submaximal exercises on treadmill for 6 minutes at an intensity corresponding to the first ventilatory threshold (VT1), and a running performance test (5000 m). Eighteen, well-trained, middle-distance runners. Maximal oxygen consumption, MVC, running performance, running efficiency, submaximal VO(2) kinetics parameters (VO(2), VO(2)b, time constant τ, and amplitude A1) and anthropometric parameters were recorded or calculated. At the end of Ramadan fasting, a decrease in MVC was observed (-3.2%; P < 0.00001; η, 0.80), associated with an increase in the time constant of oxygen kinetics (+51%; P < 0.00007; η, 0.72) and a decrease in performance (-5%; P < 0.0007; η, 0.51). No effect was observed on running efficiency or maximal aerobic power. These results suggest that Ramadan changes in muscular performance and oxygen kinetics could affect performance during middle-distance events and need to be considered to choose training protocols during RIF.
Adaptive Circuits for the 0.5-V Nanoscale CMOS Era
NASA Astrophysics Data System (ADS)
Itoh, Kiyoo; Yamaoka, Masanao; Oshima, Takashi
The minimum operating voltage, Vmin, of nanoscale CMOS LSIs is investigated to breach the 1-V wall that we are facing in the 65-nm device generation, and open the door to the below 0.5-V era. A new method using speed variation is proposed to evaluate Vmin. It shows that Vmin is very sensitive to the lowest necessary threshold voltage, Vt0, of MOSFETs and to threshold-voltage variations, ΔVt, which become more significant with device scaling. There is thus a need for low-Vt0 circuits and ΔVt-immune MOSFETs to reduce Vmin. For memory-rich LSIs, the SRAM block is particularly problematic because it has the highest Vmin. Various techniques are thus proposed to reduce the Vmin: using RAM repair, shortening the data line, up-sizing, and using more relaxed MOSFET scaling. To effectively reduce Vmin of other circuit blocks, dual-Vt0 and dual-VDD circuits using gate-source reverse biasing, temporary activation, and series connection of another small low-Vt0 MOSFET are proposed. They are dynamic logic circuits enabling the power-delay product of the conventional static CMOS inverter to be reduced to 0.09 at a 0.2-V supply, and a DRAM dynamic sense amplifier and power switches operable at below 0.5V. In addition, a fully-depleted structure (FD-SOI) and fin-type structure (FinFET) for Vt-immune MOSFETs are discussed in terms of their low-voltage potential and challenges. As a result, the height up-scalable FinFETs turns out to be quite effective to reduce Vmin to less than 0.5V, if combined with the low-Vt0 circuits. For mixed-signal LSIs, investigation of low-voltage potential of analog circuits, especially for comparators and operational amplifiers, reveals that simple inverter op-amps, in which the low gain and nonlinearity are compensated for by digitally assisted analog designs, are crucial to 0.5-V operations. Finally, it is emphasized that the development of relevant devices and fabrication processes is the key to the achievement of 0.5-V nanoscale LSIs.
Okudan, N; Gökbel, H
2006-03-01
The aim of the present study was to investigate the relationships between critical power (CP), maximal aerobic power and the anaerobic threshold and whether exercise time to exhaustion and work at the CP can be used as an index in the determination of endurance. An incremental maximal cycle exercise test was performed on 30 untrained males aged 18-22 years. Lactate analysis was carried out on capillary blood samples at every 2 minutes. From gas exchange parameters and heart rate and lactate values, ventilatory anaerobic thresholds, heart rate deflection point and the onset of blood lactate accumulation were calculated. CP was determined with linear work-time method using 3 loads. The subjects exercised until they could no longer maintain a cadence above 24 rpm at their CP and exercise time to exhaustion was determined. CP was lower than the power output corresponding to VO2max, higher than the power outputs corresponding to anaerobic threshold. CP was correlated with VO2max and anaerobic threshold. Exercise time to exhaustion and work at CP were not correlated with VO2max and anaerobic threshold. Because of the correlations of the CP with VO2max and anaerobic threshold and no correlation of exercise time to exhaustion and work at the CP with these parameters, we conclude that exercise time to exhaustion and work at the CP cannot be used as an index in the determination of endurance.
Peddareddy, Lakshmi; Merchant, Faisal M; Leon, Angel R; Smith, Paige; Patel, Akshar; El-Chami, Mikhael F
2018-06-12
Defibrillation threshold (DFT) testing is recommended with the subcutaneous ICD (SICD). To describe first shock efficacy for appropriate SICD therapies stratified by the presence of implant DFT testing. We reviewed all patients receiving SICDs at our institution and stratified them based on whether implant DFT testing was performed. Appropriate shocks were reviewed to see if ventricular tachycardia/ventricular fibrillation (VT/VF) terminated with a single shock. First shock efficacy was stratified by implant DFT status. 178 patients implanted with SICDs and followed in our center were included in this study. Of these, 135 (76 %) underwent DFT testing (DFT (+) group). In the DFT (+) 80 appropriate shocks were needed to treat 69 episodes of VT/VF. The first shock was effective in 61 out of 69 episodes (88.4 %), whereas multiple shocks were required to terminate VT/VF in the remaining 8 episodes. Among 43 patients without implant DFT testing (DFT (-) group), 20 appropriate shocks to treat 17 episodes of VT/VF occurred in 7 patients. VT/VF was successfully terminated with the first shock in 16 out of 17 episodes (first shock efficacy 94.1 %). There was no significant difference in first shock effectiveness between those with and without implant DFT testing (p = 0.97). A strategy that omits DFT testing at implant did not appear to compromise the effictiveness of the SICD. These data suggest that routine DFT testing at SICD implant might not be necessary. Randomized trials are needed to confirm this finding. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
EDGE2D-EIRENE modelling of near SOL E r: possible impact on the H-mode power threshold
NASA Astrophysics Data System (ADS)
Chankin, A. V.; Delabie, E.; Corrigan, G.; Harting, D.; Maggi, C. F.; Meyer, H.; Contributors, JET
2017-04-01
Recent EDGE2D-EIRENE simulations of JET plasmas showed a significant difference between radial electric field (E r) profiles across the separatrix in two divertor configurations, with the outer strike point on the horizontal target (HT) and vertical target (VT) (Chankin et al 2016 Nucl. Mater. Energy, doi: 10.1016/j.nme.2016.10.004). Under conditions (input power, plasma density) where the HT plasma went into the H-mode, a large positive E r spike in the near scrape-off layer (SOL) was seen in the code output, leading to a very large E × B shear across the separatrix over a narrow region of a fraction of a cm width. No such E r feature was obtained in the code solution for the VT configuration, where the H-mode power threshold was found to be twice as high as in the HT configuration. It was hypothesised that the large E × B shear across the separatrix in the HT configuration could be responsible for the turbulence suppression leading to an earlier (at lower input power) L-H transition compared to the VT configuration. In the present work these ideas are extended to cover some other experimental observations on the H-mode power threshold variation with parameters which typically are not included in the multi-machine H-mode power threshold scalings, namely: ion mass dependence (isotope H-D-T exchange), dependence on the ion ∇B drift direction, and dependence on the wall material composition (ITER-like wall versus carbon wall in JET). In all these cases EDGE2D-EIRENE modelling shows larger positive E r spikes in the near SOL under conditions where the H-mode power threshold is lower, at least in the HT configuration.
NASA Astrophysics Data System (ADS)
Wang, Ming-Tsong; Hsu, De-Cheng; Juan, Pi-Chun; Wang, Y. L.; Lee, Joseph Ya-min
2010-09-01
Metal-oxide-semiconductor capacitors and n-channel metal-oxide-semiconductor field-effect transistors with La2O3 gate dielectric were fabricated. The positive bias temperature instability was studied. The degradation of threshold voltage (ΔVT) showed an exponential dependence on the stress time in the temperature range from 25 to 75 °C. The degradation of subthreshold slope (ΔS) and gate leakage (IG) with stress voltage was also measured. The degradation of VT is attributed to the oxide trap charges Qot. The extracted activation energy of 0.2 eV is related to a degradation dominated by the release of atomic hydrogen in La2O3 thin films.
Can high-intensity exercise be more pleasant?: attentional dissociation using music and video.
Jones, Leighton; Karageorghis, Costas I; Ekkekakis, Panteleimon
2014-10-01
Theories suggest that external stimuli (e.g., auditory and visual) may be rendered ineffective in modulating attention when exercise intensity is high. We examined the effects of music and parkland video footage on psychological measures during and after stationary cycling at two intensities: 10% of maximal capacity below ventilatory threshold and 5% above. Participants (N = 34) were exposed to four conditions at each intensity: music only, video only, music and video, and control. Analyses revealed main effects of condition and exercise intensity for affective valence and perceived activation (p < .001), state attention (p < .05), and exercise enjoyment (p < .001). The music-only and music-and-video conditions led to the highest valence and enjoyment scores during and after exercise regardless of intensity. Findings indicate that attentional manipulations can exert a salient influence on affect and enjoyment even at intensities slightly above ventilatory threshold.
Energy expenditure and influence of physiologic factors during marathon running.
Loftin, Mark; Sothern, Melinda; Koss, Cathie; Tuuri, Georgianna; Vanvrancken, Connie; Kontos, Anthony; Bonis, Marc
2007-11-01
This study examined energy expenditure and physiologic determinants for marathon performance in recreational runners. Twenty recreational marathon runners participated (10 males aged 41 +/- 11.3 years, 10 females aged 42.7 +/- 11.7 years). Each subject completed a V(.-)O2max and a 1-hour treadmill run at recent marathon pace, and body composition was indirectly determined via dual energy X-ray absorptiometry. The male runners exhibited higher V(.-)O2max (ml x kg(-1) x min(-1)) values (52.6 +/- 5.5) than their female counterparts (41.9 +/- 6.6), although ventilatory threshold (T-vent) values were similar between groups (males: 76.2 +/- 6.1 % of V(.-)O2max, females: 75.1 +/- 5.1%). The male runners expended more energy (2,792 +/- 235 kcal) for their most recent marathon as calculated from the 1-hour treadmill run at marathon pace than the female runners (2,436 +/- 297 kcal). Body composition parameters correlated moderately to highly (r ranging from 0.50 to 0.87) with marathon run time. Also, V(.-)O2max (r = -0.73) and ventilatory threshold (r = -0.73) moderately correlated with marathon run time. As a group, the participants ran near their ventilatory threshold for their most recent marathon (r = 0.74). These results indicate the influence of body size on marathon run performance. In general, the larger male and female runners ran slower and expended more kilocalories than smaller runners. Regardless of marathon finishing time, the runners maintained a pace near their T-vent, and as T-vent or V(.-)O2max increased, marathon performance time decreased.
Physiological Demands of Simulated Off-Road Cycling Competition
Smekal, Gerhard; von Duvillard, Serge P.; Hörmandinger, Maximilian; Moll, Roland; Heller, Mario; Pokan, Rochus; Bacharach, David W.; LeMura, Linda M.; Arciero, Paul
2015-01-01
The purpose of the study was to measure the demands of off-road cycling via portable spirometry, leg-power output (PO), heart rate (HR) and blood lactate (BLa) concentration. Twenty-four male competitive cyclists (age: 29±7.2 yrs, height: 1.79 ± 0.05 m, body mass: 70.0 ± 4.9 kg, VO2peak: 64.9 ± 7.5 ml·kg-1·min-1) performed simulated mountain bike competitions (COMP) and laboratory tests (LabT). From LabT, we determined maximal workload and first and second ventilatory thresholds (VT1, VT2). A high-performance athlete (HPA) was used for comparison with three groups of subjects with different sport-specific performance levels. Load profiles of COMP were also investigated during uphill, flat and downhill cycling. During the COMP, athletes achieved a mean oxygen uptake (VO2COMP) of 57.0 ± 6.8 ml·kg-1·min-1 vs. 71.1 ml·kg-1·min-1 for the HPA. The POCOMP was 2.66±0.43 W·kg-1 and 3.52 W·kg-1 for the HPA. POCOMP, VO2COMP and HRCOMP were compared to corresponding variables at the VT2 of LabT. LabT variables correlated with racing time (RTCOMP) and POCOMP (p < 0.01 to <0.001; r-0.59 to -0.80). The VO2peak (LabT) accounted for 65% of variance of a single COMP test. VO2COMP, POCOMP and also endurance variables measured from LabTs were found as important determinants for cross-country performance. The high average VO2COMP indicates that a high aerobic capacity is a prerequisite for successful COMP. Findings derived from respiratory gas measures during COMPs might be useful when designing mountain bike specific training. Key points Cross- country cycling is characterized by high oxygen costs due to the high muscle mass simultaneously working to fulfill the demands of this kind of sports. Heart rate and blood lactate concentration measures are not sensitive enough to assess the energy requirements of COMP. Therefore, respiratory gas and power output measures are helpful to provide new information to physiological profile of cross- country cycling. An excellent cycling-specific capacity is a prerequisite for successful off-road cycling. Data determined from LabT might be utilized to describe semi-specific abilities of MB- athletes on a cycle ergometer, while data originating from COMP might be useful when designing a mountain bike specific training. PMID:26664277
Saengsuwan, Jittima; Huber, Celine; Schreiber, Jonathan; Schuster-Amft, Corina; Nef, Tobias; Hunt, Kenneth J
2015-09-26
We evaluated the feasibility of an augmented robotics-assisted tilt table (RATT) for incremental cardiopulmonary exercise testing (CPET) and exercise training in dependent-ambulatory stroke patients. Stroke patients (Functional Ambulation Category ≤ 3) underwent familiarization, an incremental exercise test (IET) and a constant load test (CLT) on separate days. A RATT equipped with force sensors in the thigh cuffs, a work rate estimation algorithm and real-time visual feedback to guide the exercise work rate was used. Feasibility assessment considered technical feasibility, patient tolerability, and cardiopulmonary responsiveness. Eight patients (4 female) aged 58.3 ± 9.2 years (mean ± SD) were recruited and all completed the study. For IETs, peak oxygen uptake (V'O2peak), peak heart rate (HRpeak) and peak work rate (WRpeak) were 11.9 ± 4.0 ml/kg/min (45 % of predicted V'O2max), 117 ± 32 beats/min (72 % of predicted HRmax) and 22.5 ± 13.0 W, respectively. Peak ratings of perceived exertion (RPE) were on the range "hard" to "very hard". All 8 patients reached their limit of functional capacity in terms of either their cardiopulmonary or neuromuscular performance. A ventilatory threshold (VT) was identified in 7 patients and a respiratory compensation point (RCP) in 6 patients: mean V'O2 at VT and RCP was 8.9 and 10.7 ml/kg/min, respectively, which represent 75 % (VT) and 85 % (RCP) of mean V'O2peak. Incremental CPET provided sufficient information to satisfy the responsiveness criteria and identification of key outcomes in all 8 patients. For CLTs, mean steady-state V'O2 was 6.9 ml/kg/min (49 % of V'O2 reserve), mean HR was 90 beats/min (56 % of HRmax), RPEs were > 2, and all patients maintained the active work rate for 10 min: these values meet recommended intensity levels for bouts of training. The augmented RATT is deemed feasible for incremental cardiopulmonary exercise testing and exercise training in dependent-ambulatory stroke patients: the approach was found to be technically implementable, acceptable to the patients, and it showed substantial cardiopulmonary responsiveness. This work has clinical implications for patients with severe disability who otherwise are not able to be tested.
Association between the electromyographic fatigue threshold and ventilatory threshold.
Camata, T V; Lacerda, T R; Altimari, L R; Bortolloti, H; Fontes, E B; Dantas, J L; Nakamura, F Y; Abrão, T; Chacon-Mikahil, M P T; Moraes, A C
2009-01-01
The objective of this study is to verify the coincidence between the occurrence of the electromyographic fatigue threshold (EMGth) and the ventilatory threshold (Vth) in an incremental test in the cyclosimulator, as well as to compare the calculation of the RMS from the EMG signal using different time windows. Thirteen male cyclists (73.7 +/- 12.4 kg and 174.3 +/- 6.2 cm) performed a ramp incremental test (TI) in a cyclosimulator until voluntary exhaustion. Before the start of each TI subjects had the active bipolar electrodes placed over the superficial muscles of the quadriceps femoris (QF) of the right leg: rectus femoris (RF), vastus medialis (VM) and vastus lateralis (VL). The paired student's t test, pearson's correlation coefficient and the analysis method described by Bland and Altman for the determination of the concordance level were used for statistical analysis. The significance level adopted was P < 0.05. Although no significant differences were found between Vth and the EMGth calculated from windows of 2, 5, 10, 30 and 60 seconds in the studied muscles, it is suggested that the EMGth values determined from the calculation of the RMS curve with windows of 5 and 10 seconds seem to be more appropriate for the calculation of the RMS curve and determination of EMGth from visual inspection.
Hollier, Carly Ann; Harmer, Alison Rosemary; Maxwell, Lyndal Jane; Menadue, Collette; Willson, Grant Neville; Unger, Gunnar; Flunt, Daniel; Black, Deborah Ann; Piper, Amanda Jane
2014-04-01
In people with obesity hypoventilation syndrome (OHS), breathing 100% oxygen increases carbon dioxide (PCO2), but its effect on pH is unknown. This study investigated the effects of moderate concentrations of supplemental oxygen on PCO2, pH, minute ventilation (VE) and physiological dead space to tidal volume ratio (VD/VT) among people with stable untreated OHS, with comparison to healthy controls. In a double-blind randomised crossover study, participants breathed oxygen concentrations (FiO2) 0.28 and 0.50, each for 20 min, separated by a 45 min washout period. Arterialised-venous PCO2 (PavCO2) and pH, VE and VD/VT were measured at baseline, then every 5 min. Data were analysed using general linear model analysis. 28 participants were recruited (14 OHS, 14 controls). Among OHS participants (mean ± SD arterial PCO2 6.7 ± 0.5 kPa; arterial oxygen 8.9 ± 1.4 kPa) FiO2 0.28 and 0.50 maintained oxygen saturation 98-100%. After 20 min of FiO2 0.28, PavCO2 change (ΔPavCO2) was 0.3 ± 0.2 kPa (p = 0.013), with minimal change in VE and rises in VD/VT of 1 ± 5% (p = 0.012). FiO2 0.50 increased PavCO2 by 0.5 ± 0.4 kPa (p = 0.012), induced acidaemia and increased VD/VT by 3 ± 3% (p = 0.012). VE fell by 1.2 ± 2.1 L/min within 5 min then recovered individually to varying degrees. A negative correlation between ΔVE and ΔPavCO2 (r = -0.60, p = 0.024) suggested that ventilatory responses were the key determinant of PavCO2 rises. Among controls, FiO2 0.28 and 0.50 did not change PavCO2 or pH, but FiO2 0.50 significantly increased VE and VD/VT. Commonly used oxygen concentrations caused hypoventilation, PavCO2 rises and acidaemia among people with stable OHS. This highlights the potential dangers of this common intervention in this group.
Vilozni, Daphna; Alcaneses-Ofek, Maria Rosario; Reuveny, Ronen; Rosenblum, Omer; Inbar, Omri; Katz, Uriel; Ziv-Baran, Tomer; Dubnov-Raz, Gal
2016-12-01
Pulmonary mechanics may play a role in exercise intolerance in patients with congenital heart disease (CHD). A reduced FVC volume could increase the ratio between mid-flow (FEF 25-75% ) and FVC, which is termed high dysanapsis. The relationship between high dysanapsis and the response to maximum-intensity exercise in children with CHD had not yet been studied. The aim of this work was to examine whether high dysanapsis is related to the cardiopulmonary response to maximum-intensity exercise in pediatric subjects with CHD. We retrospectively collected data from 42 children and adolescents with CHD who had either high dysanapsis (ratio >1.2; n = 21) or normal dysanapsis (control) (n = 21) as measured by spirometry. Data extracted from cardiopulmonary exercise test reports included peak values of heart rate, work load, V̇ O 2 , V̇ CO 2 , and ventilation parameters and submaximum values, including ventilatory threshold and ventilatory equivalents. There were no significant differences in demographic and clinical parameters between the groups. Participants with high dysanapsis differed from controls in lower median peak oxygen consumption (65.8% vs 83.0% of predicted, P = .02), peak oxygen pulse (78.6% vs 87.8% of predicted, P = .02), ventilatory threshold (73.8% vs 85.3% of predicted, P = .03), and maximum breathing frequency (106% vs 121% of predicted, P = .035). In the high dysanapsis group only, median peak ventilation and tidal volume were significantly lower than 80% of predicted values. In children and adolescents with corrected CHD, high dysanapsis was associated with a lower ventilatory capacity and reduced aerobic fitness, which may indicate respiratory muscle impairments. Copyright © 2016 by Daedalus Enterprises.
Fabre, Nicolas; Bortolan, Lorenzo; Pellegrini, Barbara; Zerbini, Livio; Mourot, Laurent; Schena, Federico
2012-02-01
This study aimed at questioning the validity of the ventilatory method to determine the anaerobic threshold (respiratory compensation point [RCP]) during an incremental roller-ski skating test to exhaustion. Nine elite crosscountry skiers were evaluated. The skiers carried out an incremental roller-ski test on a treadmill with the V2 skating technique. Ventilatory parameters were continuously collected breath by breath, thanks to a portable gas exchange measurement system. Poling signal was obtained using instrumented ski poles. For each stage, ventilatory and poling signals were synchronized and averaged. The poor coefficient of interobserver reliability for the time at RCP confirmed the great difficulty felt by the 3 blinded reviewers for the RCP determination. Moreover, the reviewer agreed with the impossibility of determining RCP in 4 of the 9 skiers. There was no significant difference between breathing frequency (Bf) and poling frequency (Pf) during the last 8 stages. However, it seems that the differences observed during the first stages arose from the use of either a strictly 1:1 or a 1:2 Bf to Pf ratio when the exercise intensity was still moderate. So, even if there were significant differences between the frequencies, the Bf was strictly subordinate to the Pf during the entire test. In the same way, the normalized tidal volume and peak poling forces curves were superposable. These findings showed that when the upper body is mainly involved in the propulsion, the determinants of the ventilation are strictly dependent on the poling pattern during an incremental test to exhaustion. Thus, during roller-ski skating, the determination of RCP must be used cautiously because too much depending on mechanical factors.
Hayashi, Keiji; Kawashima, Takayo; Suzuki, Yuichi
2012-07-01
To examine the effect of menstrual cycle on the ventilatory sensitivity to rising body temperature, ten healthy women exercised for ~60 min on a cycle ergometer at 50% of peak oxygen uptake during the follicular and luteal phases of their cycle. Esophageal temperature, mean skin temperature, mean body temperature, minute ventilation, and tidal volume were all significantly higher at baseline and during exercise in the luteal phase than the follicular phase. On the other hand, end-tidal partial pressure of carbon dioxide was significantly lower during exercise in the luteal phase than the follicular phase. Plotting ventilatory parameters against esophageal temperature revealed there to be no significant menstrual cycle-related differences in the slopes or intercepts of the regression lines, although minute ventilation and tidal volume did significantly differ during exercise with mild hyperthermia. To evaluate the cutaneous vasodilatory response, relative laser-Doppler flowmetry values were plotted against mean body temperature, which revealed that the mean body temperature threshold for cutaneous vasodilation was significantly higher in the luteal phase than the follicular phase, but there were no significant differences in the sensitivity or peak values. These results suggest that the menstrual cycle phase influences the cutaneous vasodilatory response during exercise and the ventilatory response at rest and during exercise with mild hyperthermia, but it does not influence ventilatory responses during exercise with moderate hyperthermia.
Effects of Carbon Dioxide and UBA-Like Breathing Resistance on Exercise Endurance
2010-04-01
hemoglobin saturation in healthy subjects and dissolved oxygen at atmospheric pressure contributes little to total oxygen transport, anaerobic threshold and...resistance of their breathing circuit is minimal increase VE both at rest and during mild to moderate (below ventilatory threshold ) exercise.2–8...of fatigue for one hour, after which we stopped him. Data for Phase 2 also are reported for only ten of the twelve subjects. We disregarded all
Vignati, Carlo; Apostolo, Anna; Cattadori, Gaia; Farina, Stefania; Del Torto, Alberico; Scuri, Silvia; Gerosa, Gino; Bottio, Tomaso; Tarzia, Vincenzo; Bejko, Jonida; Sisillo, Erminio; Nicoli, Flavia; Sciomer, Susanna; Alamanni, Francesco; Paolillo, Stefania; Agostoni, Piergiuseppe
2017-03-01
Peak exercise cardiac output (CO) increase is associated with an increase of peak oxygen uptake (VO 2 ), provided that arteriovenous O 2 difference [Δ(Ca-Cv)O 2 ] does not decrease. At anaerobic threshold, VO 2 , is related to CO. We tested the hypothesis that, in heart failure (HF) patients with left ventricular assistance device (LVAD), an acute increase of CO obtained through changes in LVAD pump speed is associated with peak exercise and anaerobic threshold VO 2 increase. Fifteen of 20 patients bearing LVAD (Jarvik 2000) enrolled in the study successfully performed peak exercise evaluation. All patients had severe HF as shown by clinical evaluation, laboratory tests, echocardiography, spirometry with alveolar-capillary diffusion, and maximal cardiopulmonary exercise testing (CPET). CPETs with non-invasive CO measurements at rest and peak exercise were done on 2days at LVAD pump speed set randomly at 2 and 4. Increasing LVAD pump speed from 2 to 4 increased CO from 3.4±0.9 to 3.8±1.0L/min (ΔCO 0.4±0.6L/min, p=0.04) and from 5.3±1.3 to 5.9±1.4L/min (ΔCO 0.6±0.7L/min, p<0.01) at rest and peak exercise, respectively. Similarly, VO 2 increased from 788±169 to 841±152mL/min (ΔVO 2 52±76mL/min, p=0.01) and from 568±116 to 619±124mL/min (ΔVO 2 69±96mL/min, p=0.02) at peak exercise and at anaerobic threshold, respectively. Δ(Ca-Cv)O 2 did not change significantly, while ventilatory efficiency improved (VE/VCO 2 slope from 39.9±5.4 to 34.9±8.3, ΔVE/VCO 2 -5.0±6.4, p<0.01). In HF, an increase in CO with a higher LVAD pump speed is associated with increased peak VO 2 , postponed anaerobic threshold, and improved ventilatory efficiency. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Ventilatory muscle endurance training in quadriplegia: effects on breathing pattern.
Loveridge, B; Badour, M; Dubo, H
1989-10-01
We examined the effects of ventilatory muscle endurance training on resting breathing pattern in 12 C6-C7 traumatic quadriplegics at least 1 year post-injury. All subjects had complete motor loss below the lesion level. Subjects were randomly assigned to a training (N = 6), or a control group (N = 6). Baseline tests included measurement of resting ventilation and breathing pattern using mercury in rubber strain gauges for 20 minutes in a seated position; maximum inspiratory mouth pressure (MIP) at FRC, and sustainable inspiratory mouth pressure for 10 minutes (SIP); lung volumes, and arterial blood gases (ABG's). The training protocol consisted of breathing through an inspiratory resistor equivalent to 85% SIP for 15 minutes twice daily, 5 days a week for 8 weeks. Both trainers and controls attended the lab every 2 weeks for reassessment of MIP and SIP and the inspiratory resistance was increased in the training group as SIP increased. At the end of 8 weeks, baseline tests were repeated. All subjects had normal ABG's. There was a significant increase in mean MIP and SIP in both the control group (30% +/- 19% and 31% +/- 18% respectively), and in the training group (42% +/- 24% and 78% +/- 49% respectively). Although the absolute values for both MIP and SIP were greater in the training group than in the control group, the differences were not significant. The alterations in resting breathing pattern were also the same in both groups. Mean frequency decreased significantly in the control group (20.2/minute to 16.9/minute) and, while insignificant, the change in frequency in the training group was the same, 19.4/minute to 16.4/minute. Mean tidal volume (Vt) increased 18.2% of baseline Vt in the control group and 17.0% baseline in the trainers, resulting in no change in minute ventilation. As MIP and SIP increased similarly in both groups, the data from the control and trainers was pooled and timing changes re-evaluated pre- and post-study. A significant decrease in mean Ti/Ttot was observed, while no change in Vt/Ti was found. We concluded that the testing procedure itself provided the stimulus resulting in a significant increase in MIP and SIP. The addition of training did not increase MIP and SIP further. The increased MIP and SIP resulted in a slower and deeper breathing pattern and a significantly shorter Ti/Ttot in both trainers and control subjects.
Ferrando, Carlos; Suarez-Sipmann, Fernando; Tusman, Gerardo; León, Irene; Romero, Esther; Gracia, Estefania; Mugarra, Ana; Arocas, Blanca; Pozo, Natividad; Soro, Marina; Belda, Francisco J
2017-01-01
Low tidal volume (VT) during anesthesia minimizes lung injury but may be associated to a decrease in functional lung volume impairing lung mechanics and efficiency. Lung recruitment (RM) can restore lung volume but this may critically depend on the post-RM selected PEEP. This study was a randomized, two parallel arm, open study whose primary outcome was to compare the effects on driving pressure of adding a RM to low-VT ventilation, with or without an individualized post-RM PEEP in patients without known previous lung disease during anesthesia. Consecutive patients scheduled for major abdominal surgery were submitted to low-VT ventilation (6 ml·kg-1) and standard PEEP of 5 cmH2O (pre-RM, n = 36). After 30 min estabilization all patients received a RM and were randomly allocated to either continue with the same PEEP (RM-5 group, n = 18) or to an individualized open-lung PEEP (OL-PEEP) (Open Lung Approach, OLA group, n = 18) defined as the level resulting in maximal Cdyn during a decremental PEEP trial. We compared the effects on driving pressure and lung efficiency measured by volumetric capnography. OL-PEEP was found at 8±2 cmH2O. 36 patients were included in the final analysis. When compared with pre-RM, OLA resulted in a 22% increase in compliance and a 28% decrease in driving pressure when compared to pre-RM. These parameters did not improve in the RM-5. The trend of the DP was significantly different between the OLA and RM-5 groups (p = 0.002). VDalv/VTalv was significantly lower in the OLA group after the RM (p = 0.035). Lung recruitment applied during low-VT ventilation improves driving pressure and lung efficiency only when applied as an open-lung strategy with an individualized PEEP in patients without lung diseases undergoing major abdominal surgery. ClinicalTrials.gov NCT02798133.
Byrkjeland, Rune; Njerve, Ida U; Anderssen, Sigmund; Arnesen, Harald; Seljeflot, Ingebjørg; Solheim, Svein
2015-09-01
Few exercise trials have focused on patients with both type 2 diabetes and coronary artery disease. We investigated the effects of 1 year of exercise training on HbA1c and VO(2peak) in these patients. Patients with type 2 diabetes and coronary artery disease (n = 137) were randomised to combined exercise training or control group. HbA(1c) was measured at the beginning and end of the study. Changes in VO(2peak), and also ventilatory threshold and time to exhaustion, were assessed by cardiopulmonary exercise testing. No differences in changes between the randomised groups were observed in HbA1c and VO(2peak), whereas ventilatory threshold and time to exhaustion increased significantly in the exercise group compared with the controls (p = 0.046 and p = 0.034). In patients without previous acute myocardial infarction and diabetes microvascular complications (n = 46), the exercise group did improve HbA1c and VO(2peak) compared with the controls (p = 0.052 and p = 0.035). No significant effects of exercise training on HbA(1c) or VO(2peak) were observed in patients with type 2 diabetes and coronary artery disease, although improvements were seen in patients without vascular complications beyond coronary artery disease, implying that the degree of vascular disease may influence exercise responses. Ventilatory threshold and time to exhaustion did increase significantly, indicating improved exercise performance despite the minor change in VO(2peak). © The Author(s) 2015.
Anaerobic Threshold by Mathematical Model in Healthy and Post-Myocardial Infarction Men.
Novais, L D; Silva, E; Simões, R P; Sakabe, D I; Martins, L E B; Oliveira, L; Diniz, C A R; Gallo, L; Catai, A M
2016-02-01
The aim of this study was to determine the anaerobic threshold (AT) in a population of healthy and post-myocardial infarction men by applying Hinkley's mathematical method and comparing its performance to the ventilatory visual method. This mathematical model, in lieu of observer-dependent visual determination, can produce more reliable results due to the uniformity of the procedure. 17 middle-aged men (55±3 years) were studied in 2 groups: 9 healthy men (54±2 years); and 8 men with previous myocardial infarction (57±3 years). All subjects underwent an incremental ramp exercise test until physical exhaustion. Breath-by-breath ventilatory variables, heart rate (HR), and vastus lateralis surface electromyography (sEMG) signal were collected throughout the test. Carbon dioxide output (V˙CO2), HR, and sEMG were studied, and the AT determination methods were compared using correlation coefficients and Bland-Altman plots. Parametric statistical tests were applied with significance level set at 5%. No significant differences were found in the HR, sEMG, and ventilatory variables at AT between the different methods, such as the intensity of effort relative to AT. Moreover, important concordance and significant correlations were observed between the methods. We concluded that the mathematical model was suitable for detecting the AT in both healthy and myocardial infarction subjects. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Kishimoto, Jessica; Fenster, Aaron; Salehi, Fateme; Romano, Walter; Lee, David S. C.; de Ribaupierre, Sandrine
2016-04-01
Dilation of the cerebral ventricles is a common condition in preterm neonates with intraventricular hemorrhage (IVH). This post hemorrhagic ventricle dilation (PHVD) can lead to lifelong neurological impairment through ischemic injury due to increased intracranial pressure and without treatment, can lead to death. Clinically, 2D ultrasound (US) through the fontanelles ('soft spots') of the patients are serially acquired to monitor the progression of the ventricle dilation. These images are used to determine when interventional therapies such as needle aspiration of the built up cerebrospinal fluid (CSF) ('ventricle tap', VT) might be indicated for a patient; however, quantitative measurements of the growth of the ventricles are often not performed. There is no consensus on when a neonate with PHVD should have an intervention and often interventions are performed after the potential for brain damage is quite high. Previously we have developed and validated a 3D US system to monitor the progression of ventricle volumes (VV) in IVH patients. We will describe the potential utility of quantitative 2D and 3D US to monitor and manage PHVD in neonates. Specifically, we will look to determine image-based measurement thresholds for patients who will require VT in comparison to patients with PHVD who resolve without intervention. Additionally, since many patients who have an initial VT will require subsequent interventions, we look at the potential for US to determine which PHVD patients will require additional VT after the initial one has been performed.
Nastasi, Michael Anthony; Wang, Yongqiang; Fraboni, Beatrice; Cosseddu, Piero; Bonfiglio, Annalisa
2013-06-11
Organic thin film devices that included an organic thin film subjected to a selected dose of a selected energy of ions exhibited a stabilized mobility (.mu.) and threshold voltage (VT), a decrease in contact resistance R.sub.C, and an extended operational lifetime that did not degrade after 2000 hours of operation in the air.
Assessment of Maximum Aerobic Capacity and Anaerobic Threshold of Elite Ballet Dancers.
Wyon, Matthew A; Allen, Nick; Cloak, Ross; Beck, Sarah; Davies, Paul; Clarke, Frances
2016-09-01
An athlete's cardiorespiratory profile, maximal aerobic capacity, and anaerobic threshold is affected by training regimen and competition demands. The present study aimed to ascertain whether there are company rank differences in maximal aerobic capacity and anaerobic threshold in elite classical ballet dancers. Seventy-four volunteers (M 34, F 40) were recruited from two full-time professional classical ballet companies. All participants completed a continuous incremental treadmill protocol with a 1-km/hr speed increase at the end of each 1-min stage until termination criteria had been achieved (e.g., voluntary cessation, respiratory exchange ratio <1.15, HR ±5 bpm of estimated HRmax). Peak VO2 (5-breathe smooth) was recorded and anaerobic threshold calculated using ventilatory curve and ventilatory equivalents methods. Statistical analysis reported between-subject effects for gender (F1,67=35.18, p<0.001) and rank (F1,67=8.67, p<0.001); post hoc tests reported soloists (39.5±5.15 mL/kg/min) as having significantly lower VO2 peak than artists (45.9±5.75 mL/kg/min, p<0.001) and principal dancers (48.07±3.24 mL/kg/min, p<0.001). Significant differences in anaerobic threshold were reported for age (F1,67=7.68, p=0.008) and rank (F1,67=3.56, p=0.034); post hoc tests reported artists (75.8±5.45%) having significantly lower anaerobic threshold than soloists (80.9±5.71, p<0.01) and principals (84.1±4.84%, p<0.001). The observed differences in VO2 peak and anaerobic threshold between the ranks in ballet companies are probably due to the different rehearsal and performance demands.
An integrative perspective of the anaerobic threshold.
Sales, Marcelo Magalhães; Sousa, Caio Victor; da Silva Aguiar, Samuel; Knechtle, Beat; Nikolaidis, Pantelis Theodoros; Alves, Polissandro Mortoza; Simões, Herbert Gustavo
2017-12-14
The concept of anaerobic threshold (AT) was introduced during the nineteen sixties. Since then, several methods to identify the anaerobic threshold (AT) have been studied and suggested as novel 'thresholds' based upon the variable used for its detection (i.e. lactate threshold, ventilatory threshold, glucose threshold). These different techniques have brought some confusion about how we should name this parameter, for instance, anaerobic threshold or the physiological measure used (i.e. lactate, ventilation). On the other hand, the modernization of scientific methods and apparatus to detect AT, as well as the body of literature formed in the past decades, could provide a more cohesive understanding over the AT and the multiple physiological systems involved. Thus, the purpose of this review was to provide an integrative perspective of the methods to determine AT. Copyright © 2017 Elsevier Inc. All rights reserved.
Webb, Cheryl L; Milsom, William K
2017-07-01
During entrance into hibernation in golden-mantled ground squirrels (Callospermophilus lateralis), ventilation decreases as metabolic rate and body temperature fall. Two patterns of respiration occur during deep hibernation. At 7 °C body temperature (T b ), a breathing pattern characterized by episodes of multiple breaths (20.6 ± 1.9 breaths/episode) separated by long apneas or nonventilatory periods (T nvp ) (mean = 11.1 ± 1.2 min) occurs, while at 4 °C T b , a pattern in which breaths are evenly distributed and separated by a relatively short T nvp (0.5 ± 0.05 min) occurs. Squirrels exhibiting each pattern have similar metabolic rates and levels of total ventilation (0.2 and 0.23 ml O 2 /hr/kg and 0.11 and 0.16 ml air/min/kg, respectively). Squirrels at 7 °C T b exhibit a significant hypoxic ventilatory response, while squirrels at 4 °C T b do not respond to hypoxia at any level of O 2 tested. Squirrels at both temperatures exhibit a significant hypercapnic ventilatory response, but the response is significantly reduced in the 4 °C T b squirrels. Carotid body denervation has little effect on the breathing patterns or on the hypercapnic ventilatory responses. It does reduce the magnitude and threshold for the hypoxic ventilatory response. Taken together the data suggest that (1) the fundamental rhythm generator remains functional at low temperatures; (2) the hypercapnic ventilatory response arises from central chemoreceptors that remain functional at very low temperatures; (3) the hypoxic ventilatory response arises from both carotid body and aortic chemoreceptors that are silenced at lower temperatures; and (4) there is a strong correlation between breathing pattern and chemosensitivity.
Carbucicchio, Corrado; Della Bella, Paolo; Fassini, Gaetano; Trevisi, Nicola; Riva, Stefania; Giraldi, Francesco; Baratto, Francesca; Marenzi, Giancarlo; Sisillo, Erminio; Bartorelli, Antonio; Alamanni, Francesco
2009-11-01
In patients with severe cardiomyopathy, recurrent episodes of nontolerated ventricular tachycardia (VT) or electrical storm (ES) frequently cause acute heart failure and cardiac death; the suppression of the arrhythmia is therefore lifesaving, but feasibility of catheter ablation (CA) is precluded by the adverse hemodynamic conditions together with the characteristics of the arrhythmia that interdicts efficacious mapping. The use of the percutaneous cardiopulmonary support (CPS) for circulatory assistance may allow patient's stabilization and enhance efficacy and safety of CA in this emergency setting. 19 patients (19 males; mean age 61 +/- 6 years; chronic ischemic cardiomyopathy, eleven patients; primary dilated cardiomyopathy, six patients; arrhythmogenic right ventricular dysplasia/ cardiomyopathy, two patients) with recurrent nontolerated VT episodes undergoing CPS-assisted CA were retrospectively evaluated. Twelve patients had acute hemodynamic failure refractory to inotropic agents and ventilatory assistance, seven patients had undergone a failing nonconventional CA procedure. 14 patients presented with ES, and in twelve the procedure was undertaken under emergency conditions within 24 h from admission. Patients were ventilated under general anesthesia and assisted by a multidisciplinary team. The CPS system consisted in a Medtronic Bio-Medicus centrifugal pump and in a Maxima Plus oxygenator, a 15-F arterial cannula, and a 17-F venous cannula. Flows between 2 and 3 l/min were activated after induction of 56/62 forms of nontolerated VT, achieving hemodynamic stabilization in all patients. CA was mainly guided by conventional activation mapping and was effective in abolishing 45/56 supported VTs; in 10/19 patients all clinical VTs were suppressed by CA. Mean procedural time was 4 h and 20 min. Complete stabilization was achieved in 13 patients (68%) without VT recurrence during a 7-day in-hospital monitoring. A significant clinical improvement was observed in two patients (11%); one patient (5%) with persistent VT episodes acutely died after heart transplant. At a mean follow-up of 42 months (range 15-60 months), 5/18 patients (28%) were free from VT recurrence, 7/18 (39%) had a clear clinical improvement with reduced implantable cardioverter defibrillator interventions. 5/14 patients (36%) had ES recurrence; among them, three died because of acute heart failure. No serious CPS-related complications were observed. The CPS warrants acceptable hemodynamic stabilization and efficacious mapping in high-risk patients undergoing CA for unstable VT in the emergency setting. Safety and efficacy of this technique translate into significant clinical improvement in the majority of patients. Even if only relatively invasive, CPS should be reserved to patients with ES or intractable arrhythmia causing acute heart failure; moreover, the need for an experienced team of multidisciplinary operators implies that its use is restricted to selected high-competency institutions.
Assessment and monitoring of flow limitation and other parameters from flow/volume loops.
Dueck, R
2000-01-01
Flow/volume (F/V) spirometry is routinely used for assessing the type and severity of lung disease. Forced vital capacity (FVC) and timed vital capacity (FEV1) provide the best estimates of airflow obstruction in patients with asthma, chronic obstructive pulmonary disease (COPD) and emphysema. Computerized spirometers are now available for early home recognition of asthma exacerbation in high risk patients with severe persistent disease, and for recognition of either infection or rejection in lung transplant patients. Patients with severe COPD may exhibit expiratory flow limitation (EFL) on tidal volume (VT) expiratory F/V (VTF/V) curves, either with or without applying negative expiratory pressure (NEP). EFL results in dynamic hyperinflation and persistently raised alveolar pressure or intrinsic PEEP (PEEPi). Hyperinflation and raised PEEPi greatly enhance dyspnea with exertion through the added work of the threshold load needed to overcome raised pleural pressure. Esophageal (pleural) pressure monitoring may be added to VTF/V loops for assessing the severity of PEEPi: 1) to optimize assisted ventilation by mask or via endotracheal tube with high inspiratory flow rates to lower I:E ratio, and 2) to assess the efficacy of either pressure support ventilation (PSV) or low level extrinsic PEEP in reducing the threshold load of PEEPi. Intraoperative tidal volume F/V loops can also be used to document the efficacy of emphysema lung volume reduction surgery (LVRS) via disappearance of EFL. Finally, the mechanism of ventilatory constraint can be identified with the use of exercise tidal volume F/V loops referenced to maximum F/V loops and static lung volumes. Patients with severe COPD show inspiratory F/V loops approaching 95% of total lung capacity, and flow limitation over the entire expiratory F/V curve during light levels of exercise. Surprisingly, patients with a history of congestive heart failure may lower lung volume towards residual volume during exercise, thereby reducing airway diameter and inducing expiratory flow limitation.
Evaluation of the Virtual Physiology of Exercise Laboratory Program
ERIC Educational Resources Information Center
Dobson, John L.
2009-01-01
The Virtual Physiology of Exercise Laboratory (VPEL) program was created to simulate the test design, data collection, and analysis phases of selected exercise physiology laboratories. The VPEL program consists of four modules: (1) cardiovascular, (2) maximal O[subscript 2] consumption [Vo[subscript 2max], (3) lactate and ventilatory thresholds,…
Mechanisms of breathing instability in patients with obstructive sleep apnea.
Younes, Magdy; Ostrowski, Michele; Atkar, Raj; Laprairie, John; Siemens, Andrea; Hanly, Patrick
2007-12-01
The response to chemical stimuli (chemical responsiveness) and the increases in respiratory drive required for arousal (arousal threshold) and for opening the airway without arousal (effective recruitment threshold) are important determinants of ventilatory instability and, hence, severity of obstructive apnea. We measured these variables in 21 obstructive apnea patients (apnea-hypopnea index 91 +/- 24 h(-1)) while on continuous-positive-airway pressure. During sleep, pressure was intermittently reduced (dial down) to induce severe hypopneas. Dial downs were done on room air and following approximately 30 s of breathing hypercapneic and/or hypoxic mixtures, which induced a range of ventilatory stimulation before dial down. Ventilation just before dial down and flow during dial down were measured. Chemical responsiveness, estimated as the percent increase in ventilation during the 5(th) breath following administration of 6% CO(2) combined with approximately 4% desaturation, was large (187 +/- 117%). Arousal threshold, estimated as the percent increase in ventilation associated with a 50% probability of arousal, ranged from 40% to >268% and was <120% in 12/21 patients, indicating that in many patients arousal occurs with modest changes in chemical drive. Effective recruitment threshold, estimated as percent increase in pre-dial-down ventilation associated with a significant increase in dial-down flow, ranged from zero to >174% and was <110% in 12/21 patients, indicating that in many patients reflex dilatation occurs with modest increases in drive. The two thresholds were not correlated. In most OSA patients, airway patency may be maintained with only modest increases in chemical drive, but instability results because of a low arousal threshold and a brisk increase in drive following brief reduction in alveolar ventilation.
Larcombe, Alexander
2002-01-01
The effects of ambient temperatures (T(a)) from 10 degrees to 35 degrees C on metabolism, ventilation, and oxygen extraction were examined for the southern brown bandicoot (Isoodon obesulus). Oxygen consumption (VO2) followed the pattern typical for endotherms, decreasing with increasing T(a) from 10 degrees to 25 degrees C. It did not significantly change between Ta=25 degrees and 35 degrees C (the thermoneutral zone). VO2 was approximately 2.4 times higher at Ta=10 degrees C (0.967 mL O(2) g(-1) h(-1)) compared with basal (0.410 mL O(2) g(-1) h(-1)) at Ta=30 degrees C. While the metabolic rates of the bandicoots were basal at Ta=30 degrees C, respiratory frequency (f(R)) was 24.6 breaths min(-1), tidal volume (V(T)) was 7.79 mL, minute volume (V(I)) was 191.3 mL min(-1), and oxygen extraction efficiency (EO2) was 26.8%. Increased VO2 at Ta< or =25 degrees C was associated with a large increase in V(I) due to increases in V(T) and f(R). A greater proportion of the change was due to the increase in tidal volume. EO2 was constant at approximately 26% for all T(a) up to and including 30 degrees C. At Ta=35 degrees C, EO2 decreased to 17.7%, f(R) increased to 35.6 breaths min(-1), and V(T) decreased to 7.22 mL. The metabolic and ventilatory physiology of the southern brown bandicoot are typical of an unspecialized medium-sized marsupial.
FLOW-i ventilator performance in the presence of a circle system leak.
Lucangelo, Umberto; Ajčević, Miloš; Accardo, Agostino; Borelli, Massimo; Peratoner, Alberto; Comuzzi, Lucia; Zin, Walter A
2017-04-01
Recently, the FLOW-i anaesthesia ventilator was developed based on the SERVO-i intensive care ventilator. The aim of this study was to test the FLOW-i's tidal volume delivery in the presence of a leak in the breathing circuit. We ventilated a test lung model in volume-, pressure-, and pressure-regulated volume-controlled modes (VC, PC, and PRVC, respectively) with a FLOW-i. First, the circuit remained airtight and the ventilator was tested with fresh gas flows of 6, 1, and 0.3 L/min in VC, PC, and PRVC modes and facing 4 combinations of different resistive and elastic loads. Second, a fixed leak in the breathing circuit was introduced and the measurements repeated. In the airtight system, FLOW-i maintained tidal volume (VT) and circuit pressure at approximately the set values, independently of respiratory mode, load, or fresh gas flow. In the leaking circuit, set VT = 500 mL, FLOW-i delivered higher VTs in PC (about 460 mL) than in VC and PRVC, where VTs were substantially less than 500 mL. Interestingly, VT did not differ appreciably from 6 to 0.3 L/min of fresh air flow among the 3 ventilatory modes. In the absence of leakage, peak inspiratory pressures were similar, while they were 35-45 % smaller in PRVC and VC than in PC mode in the presence of leaks. In conclusion, FLOW-i maintained VT (down to fresh gas flows of 0.3 L/min) to 90 % of its preset value in PC mode, which was 4-5 times greater than in VC or PRVC modes.
2017-08-01
Limited information exists about the epidemiology and outcome of surgical patients at increased risk of postoperative pulmonary complications (PPCs), and how intraoperative ventilation was managed in these patients. To determine the incidence of surgical patients at increased risk of PPCs, and to compare the intraoperative ventilation management and postoperative outcomes with patients at low risk of PPCs. This was a prospective international 1-week observational study using the 'Assess Respiratory Risk in Surgical Patients in Catalonia risk score' (ARISCAT score) for PPC for risk stratification. Adult patients requiring intraoperative ventilation during general anaesthesia for surgery in 146 hospitals across 29 countries. The primary outcome was the incidence of patients at increased risk of PPCs based on the ARISCAT score. Secondary outcomes included intraoperative ventilatory management and clinical outcomes. A total of 9864 patients fulfilled the inclusion criteria. The incidence of patients at increased risk was 28.4%. The most frequently chosen tidal volume (VT) size was 500 ml, or 7 to 9 ml kg predicted body weight, slightly lower in patients at increased risk of PPCs. Levels of positive end-expiratory pressure (PEEP) were slightly higher in patients at increased risk of PPCs, with 14.3% receiving more than 5 cmH2O PEEP compared with 7.6% in patients at low risk of PPCs (P < 0.001). Patients with a predicted preoperative increased risk of PPCs developed PPCs more frequently: 19 versus 7%, relative risk (RR) 3.16 (95% confidence interval 2.76 to 3.61), P < 0.001) and had longer hospital stays. The only ventilatory factor associated with the occurrence of PPCs was the peak pressure. The incidence of patients with a predicted increased risk of PPCs is high. A large proportion of patients receive high VT and low PEEP levels. PPCs occur frequently in patients at increased risk, with worse clinical outcome. The study was registered at Clinicaltrials.gov, number NCT01601223.
Identification of spinal circuits involved in touch-evoked dynamic mechanical pain
Cheng, Longzhen; Duan, Bo; Huang, Tianwen; Zhang, Yan; Chen, Yangyang; Britz, Olivier; Garcia-Campmany, Lidia; Ren, Xiangyu; Vong, Linh; Lowell, Bradford B.; Goulding, Martyn; Wang, Yun; Ma, Qiufu
2017-01-01
Mechanical hypersensitivity is a debilitating symptom associated with millions of chronic pain patients. It exists in distinct forms, including brush-evoked dynamic and filament-evoked punctate. Here we report that dynamic mechanical hypersensitivity induced by nerve injury or inflammation was compromised in mice with ablation of spinal VT3Lbx1 neurons defined by coexpression of VGLUT3Cre and Lbx1Flpo, as indicated by the loss of brush-evoked nocifensive responses and conditional place aversion. Electrophysiological recordings show that VT3Lbx1 neurons form morphine-resistant polysynaptic pathways relaying inputs from low-threshold Aβ mechanoreceptors to lamina I output neurons. Meanwhile, the subset of somatostatin (SOM) lineage neurons preserved in VT3Lbx1 neuron-ablated mice is largely sufficient to mediate von Frey filament-evoked punctate mechanical hypersensitivity, including both morphine-sensitive and morphine-resistant forms. Furthermore, acute silencing of VT3Lbx1 neurons attenuated pre-established dynamic mechanical hypersensitivity induced by nerve injury, suggesting these neurons as a potential cellular target for treating this form of neuropathic pain. PMID:28436981
Effect of dead space on breathing stability at exercise in hypoxia.
Hermand, Eric; Lhuissier, François J; Richalet, Jean-Paul
2017-12-01
Recent studies have shown that normal subjects exhibit periodic breathing when submitted to concomitant environmental (hypoxia) and physiological (exercise) stresses. A mathematical model including mass balance equations confirmed the short period of ventilatory oscillations and pointed out an important role of dead space in the genesis of these phenomena. Ten healthy subjects performed mild exercise on a cycloergometer in different conditions: rest/exercise, normoxia/hypoxia and no added dead space/added dead space (aDS). Ventilatory oscillations (V˙E peak power) were augmented by exercise, hypoxia and aDS (P<0.001, P<0.001 and P<0.01, respectively) whereas V˙E period was only shortened by exercise (P<0.001), with an 11-s period. aDS also increased V˙E (P<0.001), tidal volume (VT, P<0.001), and slightly augmented PETCO 2 (P<0.05) and the respiratory frequency (P<0.05). These results confirmed our previous model, showing an exacerbation of breathing instability by increasing dead space. This underlines opposite effects observed in heart failure patients and normal subjects, in which added dead space drastically reduced periodic breathing and sleep apneas. It also points out that alveolar ventilation remains very close to metabolic needs and is not affected by an added dead space. Clinical Trial reg. n°: NCT02201875. Copyright © 2017 Elsevier B.V. All rights reserved.
Optimal programming management of ventricular tachycardia storm in ICD patients
Qian, Zhiyong; Guo, Jianghong; Zhang, Zhiyong; Wang, Yao; Hou, Xiaofeng; Zou, Jiangang
2015-01-01
Abstract Ventricular tachycardia storm (VTS) is defined as a life-threatening syndrome of three or more separate episodes of ventricular tachycardia (VT) leading to implantable cardioverter defibrillator (ICD) therapy within 24 hours. Patients with VTS have poor outcomes and require immediate medical attention. ICD shocks have been shown to be associated with increased mortality in several studies. Optimal programming in minimization of ICD shocks may decrease mortality. Large controlled trials showed that long detection time and high heart rate detection threshold reduced ICD shock burden without an increase in syncope or death. As a fundamental therapy of ICD, antitachycardia pacing (ATP) can terminate most slow VT with a low risk of acceleration. For fast VT, burst pacing is more effective and less likely to result in acceleration than ramp pacing. One algorithm of optimal programming management during a VTS is presented in the review. PMID:25745473
Morard, Marie-Doriane; Besson, Delphine; Laroche, Davy; Naaïm, Alexandre; Gremeaux, Vincent; Casillas, Jean-Marie
2017-01-01
There is ambiguity concerning the walk tests available for functional assessment of coronary patients, particularly for the walking speed. This study explores the psychometric properties of two walking tests, based on fixed-distance tests, at comfortable and fast velocity, in stabilized patients at the end of a cardiac rehabilitation program. At a three-day interval 58 coronary patients (mean age of 64.85±6.03 years, 50 men) performed three walk tests, the first two at a comfortable speed in a random order (6-minute walk test - 6MWT - and 400-metre comfortable walk test - 400mCWT) and the third at a brisk speed (200-metre fast walk test - 200mFWT). A modified Bruce treadmill test was associated at the end of the second phase. Monitored main parameters were: heart rate, walking velocity, VO 2 . Tolerance to the 3 tests was satisfactory. The reliability of the main parameters was good (intraclass correlation coefficient>0.8). The VO 2 concerning 6MWT and 400mCWT were not significantly different (P=0.33) and were lower to the first ventilatory threshold determined by the stress test (P<0.001): 16.2±3.0 vs. 16.5±2.6 vs. 20.7±5.1mL·min -1 ·kg -1 respectively. The VO 2 of the 200mFWT (20.2±3.7) was not different from the first ventilatory threshold. 400mCWT and 200mFWT are feasible, well-tolerated and reliable. They explore two levels of effort intensity (lower and not different to the first ventilatory threshold respectively). 400mCWT is a possible alternative to 6MWT. Associated with 200mFWT it should allow a better measurement of physical capacities and better customization of exercise training. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Red Spinach Extract Increases Ventilatory Threshold during Graded Exercise Testing
Kephart, Wesley C.; Holland, Angelia M.; Pascoe, David D.; Roberts, Michael D.
2017-01-01
Background: We examined the acute effect of a red spinach extract (RSE) (1000 mg dose; ~90 mg nitrate (NO3−)) on performance markers during graded exercise testing (GXT). Methods: For this randomized, double-blind, placebo (PBO)-controlled, crossover study, 15 recreationally-active participants (aged 23.1 ± 3.3 years; BMI: 27.2 ± 3.7 kg/m2) reported >2 h post-prandial and performed GXT 65–75 min post-RSE or PBO ingestion. Blood samples were collected at baseline (BL), pre-GXT (65–75 min post-ingestion; PRE), and immediately post-GXT (POST). GXT commenced with continuous analysis of expired gases. Results: Plasma concentrations of NO3− increased PRE (+447 ± 294%; p < 0.001) and POST (+378 ± 179%; p < 0.001) GXT with RSE, but not with PBO (+3 ± 26%, −8 ± 24%, respectively; p > 0.05). No effect on circulating nitrite (NO2−) was observed with RSE (+3.3 ± 7.5%, +7.7 ± 11.8% PRE and POST, respectively; p > 0.05) or PBO (−0.5 ± 7.9%, −0.2 ± 8.1% PRE and POST, respectively; p > 0.05). When compared to PBO, there was a moderate effect of RSE on plasma NO2− at PRE (g = 0.50 [−0.26, 1.24] and POST g = 0.71 [−0.05, 1.48]). During GXT, VO2 at the ventilatory threshold was significantly higher with RSE compared to PBO (+6.1 ± 7.3%; p < 0.05), though time-to-exhaustion (−4.0 ± 7.7%; p > 0.05) and maximal aerobic power (i.e., VO2 peak; −0.8 ± 5.6%; p > 0.05) were non-significantly lower with RSE. Conclusions: RSE as a nutritional supplement may elicit an ergogenic response by delaying the ventilatory threshold. PMID:29910440
[Effect of training intensity on the fat oxidation rate].
Ulloa, David; Feriche, Belén; Barboza, Paola; Padial, Paulino
2014-01-01
Physical exercise is a key modulator of the maximum fat oxidation rate (MFO). However, the metabolic transition zones in the MFO-exercise relationship are not generally considered for training prescription. Objective. To examine the effects of training in different metabolic transition zones on the kinetics of MFO and its localization (Fatmax) in young physically active men. 97 men were divided into 4 similar sized groups, 3 experimental groups and a control group (CG). Subjects in each experimental group undertook an 8-week running program. Training was continuous at the intensity of the aerobic threshold or VT1 (CCVT1); or performed as intervals at the intensity of the anaerobic threshold or VT2 (ITVT2); or at maximum aerobic power VO2max (ITVO2max). Before and after the training intervention, expired gases were monitored in each subject to determine VO2max, VT1, VT2, MFO (by indirect calorimetry) and Fatmax. In response to training, experimental groups showed an increase in MFO (from 16,49 to 18,51%; p<0,01) and a mean reduction in Fatmax of 60,72±10,52 to 52,35±7,61 %VO2max (p<0,01). No changes of interest were observed in the control subjects. Intergroup comparisons revealed no differences in MFO and Fatmax among the experimental groups, though compared to the CG, a greater reduction in Fatmax was observed in CCVT1 (p<0,05). No changes were detected in performance except a drop in VO2max in the GC (p<0,05). 8 weeks of training led to an increase in MFO and reduction in Fatmax irrespective of training intensity. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Application of mid-frequency ventilation in an animal model of lung injury: a pilot study.
Mireles-Cabodevila, Eduardo; Chatburn, Robert L; Thurman, Tracy L; Zabala, Luis M; Holt, Shirley J; Swearingen, Christopher J; Heulitt, Mark J
2014-11-01
Mid-frequency ventilation (MFV) is a mode of pressure control ventilation based on an optimal targeting scheme that maximizes alveolar ventilation and minimizes tidal volume (VT). This study was designed to compare the effects of conventional mechanical ventilation using a lung-protective strategy with MFV in a porcine model of lung injury. Our hypothesis was that MFV can maximize ventilation at higher frequencies without adverse consequences. We compared ventilation and hemodynamic outcomes between conventional ventilation and MFV. This was a prospective study of 6 live Yorkshire pigs (10 ± 0.5 kg). The animals were subjected to lung injury induced by saline lavage and injurious conventional mechanical ventilation. Baseline conventional pressure control continuous mandatory ventilation was applied with V(T) = 6 mL/kg and PEEP determined using a decremental PEEP trial. A manual decision support algorithm was used to implement MFV using the same conventional ventilator. We measured P(aCO2), P(aO2), end-tidal carbon dioxide, cardiac output, arterial and venous blood oxygen saturation, pulmonary and systemic vascular pressures, and lactic acid. The MFV algorithm produced the same minute ventilation as conventional ventilation but with lower V(T) (-1 ± 0.7 mL/kg) and higher frequency (32.1 ± 6.8 vs 55.7 ± 15.8 breaths/min, P < .002). There were no differences between conventional ventilation and MFV for mean airway pressures (16.1 ± 1.3 vs 16.4 ± 2 cm H2O, P = .75) even when auto-PEEP was higher (0.6 ± 0.9 vs 2.4 ± 1.1 cm H2O, P = .02). There were no significant differences in any hemodynamic measurements, although heart rate was higher during MFV. In this pilot study, we demonstrate that MFV allows the use of higher breathing frequencies and lower V(T) than conventional ventilation to maximize alveolar ventilation. We describe the ventilatory or hemodynamic effects of MFV. We also demonstrate that the application of a decision support algorithm to manage MFV is feasible. Copyright © 2014 by Daedalus Enterprises.
Effects of Pregnancy on Responses to Exercise Above and Below the Ventilatory Anaerobic THreshold
1999-10-01
815-827, 1998. Chapers in Books Wolfe, L.A. and M.F. Mottola. Chapter on Pregnacy In: (D. Kumbhare and J.V Basmajian, Eds.). Clinical Decision Makinq...effects of All and AVP may be more easily identified in early pregnacy when progesterone levels are relatively low. Further study is recommended to
Janardhan, Ajit H.; Li, Wenwen; Fedorov, Vadim V.; Yeung, Michael; Wallendorf, Michael J.; Schuessler, Richard B.; Efimov, Igor R.
2015-01-01
Objectives To develop a low-energy electrotherapy that terminates ventricular tachycardia (VT) when anti-tachycardia pacing (ATP) fails. Background High-energy ICD shocks are associated with device failure, significant morbidity and increased mortality. A low-energy alternative to ICD shocks is desirable. Methods Myocardial infarction (MI) was created in 25 dogs. Sustained, monomorphic VT was induced by programmed stimulation. Defibrillation electrodes were placed in the RV apex, and coronary sinus (CS) and LV epicardium (LVP). If ATP failed to terminate sustained VT, the defibrillation thresholds (DFTs) of standard versus experimental electrotherapies were measured. Results Sustained VT ranged from 276–438 bpm (mean 339 bpm). The RV-CS shock vector had lower impedance than RV-LVP (54.4±18.1 Ω versus 109.8±16.9, Ω p<0.001). A single shock required between 0.3±0.2 J to 5.9±2.5 J (mean 2.64±3.22 J; p=0.008) to terminate VT, and varied depending upon the phase of the VT cycle at which it was delivered. In contrast, multiple shocks delivered within 1 VT cycle length were not phase-dependent and achieved lower DFT compared to a single shock (0.13±0.09 J for 3 shocks, 0.08±0.04 J for 5 shocks, 0.09±0.07 J for 7 shocks; p<0.001). Finally, a multi-stage electrotherapy (MSE) achieved significantly lower DFT compared to a single biphasic shock (0.03±0.05 J versus 2.37±1.20 J, respectively, p<0.001). At a peak shock amplitude of 20 V, MSE achieved 91.3% of terminations versus 10.5% for a biphasic shock (p<0.001). Conclusions MSE achieved a major reduction in DFT compared to a single biphasic shock for ATP-refractory monomorphic VT, and represents a novel electrotherapy to reduce high-energy ICD shocks. PMID:23141483
Fabre, Claudine; Chehere, Baptiste; Bart, Frédéric; Mucci, Patrick; Wallaert, Benoit; Grosbois, Jean Marie
2017-01-01
Background It has been scientifically proven that pulmonary rehabilitation improves exercise tolerance and facilitates the carrying out of daily physical activities. To optimize the physical and physiological benefits, it is necessary to individualize the training intensity for each patient. The aim of this study is to compare the heart rate (HR) responses to three exercise modalities measuring aerobic fitness in chronic obstructive pulmonary disease patients, in order to easily prescribe individual target HRs for endurance training. Patients and method Fifty COPD patients (mean age: 60.1±8.5 years) were included in the study. Each patient carried out a cardiopulmonary exercise test, a 6-minute walk test (6MWT) and a 6-minute stepper test (6MST). During these tests, HR was recorded continuously. After the cardiopulmonary exercise test, the HR was noted at the ventilatory threshold (VT) and at the end of the two exercise field tests (6MWTpeak and 6MSTpeak). The values of the HR during the last 3 minutes of both field tests were averaged (6MWT456 and 6MST456). Finally, the HR at 60% of the HR reserve was calculated with the values of the HR measured during 6MWT and 6MST (HRr60%walk, HRr60%step). Results The HRs measured during the 6MST were significantly higher than those measured during the 6MWT. The HRr60%step was not significantly different from 6MWT456 and 6MWTpeak HR (P=0.51; P=0.48). A significant correlation was observed between 6MWT456 and 6MWTpeak (r=0.58). The 6MWT456 and 6MWTpeak HR were correlated with HRr60%step (r=0.68 and r=0.62). The VT could be determined in 28 patients. The HRVT was not different from 6MWT456, 6MWTpeak, and HRr60%step (P=0.57, P=0.41 and P=0.88) and was correlated to 6MWT456, 6MWTpeak, and HRr60%step (r=0.45, r=0.40, r=0.48). Conclusion An individualized target HR for endurance training can be prescribed from the HR measured during routine tests, such as 6MWT or 6MST. PMID:28553100
NASA Astrophysics Data System (ADS)
Hu, Cheng-Yu; Nakatani, Katsutoshi; Kawai, Hiroji; Ao, Jin-Ping; Ohno, Yasuo
To improve the high voltage performance of AlGaN/GaN heterojunction field effect transistors (HFETs), we have fabricated AlGaN/GaN HFETs with p-GaN epi-layer on sapphire substrate with an ohmic contact to the p-GaN (p-sub HFET). Substrate bias dependent threshold voltage variation (VT-VSUB) was used to directly determine the doping concentration profile in the buffer layer. This VT-VSUB method was developed from Si MOSFET. For HFETs, the insulator is formed by epitaxially grown and heterogeneous semiconductor layer while for Si MOSFETs the insulator is amorphous SiO2. Except that HFETs have higher channel mobility due to the epitaxial insulator/semiconductor interface, HFETs and Si MOSFETs are basically the same in the respect of device physics. Based on these considerations, the feasibility of this VT-VSUB method for AlGaN/GaN HFETs was discussed. In the end, the buffer layer doping concentration was measured to be 2 × 1017cm-3, p-type, which is well consistent with the Mg concentration obtained from secondary ion mass spectroscopy (SIMS) measurement.
Nava-Guerra, L; Tran, W H; Chalacheva, P; Loloyan, S; Joshi, B; Keens, T G; Nayak, K S; Davidson Ward, S L; Khoo, M C K
2016-07-01
Obstructive sleep apnea (OSA) involves the interplay of several different factors such as an unfavorable upper airway anatomy, deficiencies in pharyngeal muscle responsiveness, a low arousal threshold, and ventilatory control instability. Although the stability of ventilatory control has been extensively studied in adults, little is known about its characteristics in the pediatric population. In this study, we developed a novel experimental setup that allowed us to perturb the respiratory system during natural non-rapid eye movement (NREM) sleep conditions by manipulating the inspiratory pressure, provided by a bilevel pressure ventilator, to induce sighs after upper airway stabilization. Furthermore, we present a modeling framework that utilizes the noninvasively measured ventilatory responses to the induced sighs and spontaneous breathing data to obtain representations of the processes involved in the chemical regulation of respiration and extract their stability characteristics. After validation with simulated data, the modeling technique was applied to data collected experimentally from 11 OSA and 15 non-OSA overweight adolescents. Statistical analysis of the model-derived stability parameters revealed a significantly higher plant gain and lower controller gain in the OSA group (P = 0.046 and P = 0.007, respectively); however, no differences were found in loop gain (LG) and circulatory time delay between the groups. OSA severity and LG, within the 0.03-0.04-Hz frequency band, were significantly negatively associated (r = -0.434, P = 0.026). Contrary to what has been found in adults, our results suggest that in overweight adolescents, OSA is unlikely to be initiated through ventilatory instability resulting from elevated chemical loop gain. Copyright © 2016 the American Physiological Society.
Ventilatory responses to dynamic exercise elicited by intramuscular sensors
NASA Technical Reports Server (NTRS)
Smith, S. A.; Gallagher, K. M.; Norton, K. H.; Querry, R. G.; Welch-O'Connor, R. M.; Raven, P. B.
1999-01-01
PURPOSE: Eight subjects, aged 27.0+/-1.6 yr, performed incremental workload cycling to investigate the contribution of skeletal muscle mechano- and metaboreceptors to ventilatory control during dynamic exercise. METHODS: Each subject performed four bouts of exercise: exercise with no intervention (CON); exercise with bilateral thigh cuffs inflated to 90 mm Hg (CUFF); exercise with application of lower-body positive pressure (LBPP) to 45 torr (PP); and exercise with 90 mm Hg thigh cuff inflation and 45 torr LBPP (CUFF+PP). Ventilatory responses and pulmonary gas exchange variables were collected breath-by-breath with concomitant measurement of leg intramuscular pressure. RESULTS: Ventilation (VE) was significantly elevated from CON during PP and CUFF+PP at workloads corresponding to > or = 60% CON peak oxygen uptake (VO2peak) and during CUFF at workloads > or = 80% CON VO2peak, P < 0.05. The VO2 at which ventilatory threshold occurred was significantly reduced from CON (2.17+/-0.28 L x min(-1)) to 1.60+/-0.19 L x min(-1), 1.45+/-0.15 L x min(-1), and 1.15+/-0.11 L x min(-1) during CUFF, PP, and CUFF+PP, respectively. The slope of the linear regression describing the VE/CO2 output relationship was increased from CON by approximately 22% during CUFF, 40% during PP, and 41% during CUFF+PP. CONCLUSIONS: As intramuscular pressure was significantly elevated immediately upon application of LBPP during PP and CUFF+PP without a concomitant increase in VE, it seems unlikely that LBPP-induced increases in VE can be attributed to activation of the mechanoreflex. These findings suggest that LBPP-induced reductions in perfusion pressure and decreases in venous outflow resulting from inflation of bilateral thigh cuffs may generate a metabolite sensitive intramuscular ventilatory stimulus.
Visschers, Naomi C A; Hulzebos, Erik H; van Brussel, Marco; Takken, Tim
2015-11-01
The ventilatory anaerobic threshold (VAT) is an important method to assess the aerobic fitness in patients with cardiopulmonary disease. Several methods exist to determine the VAT; however, there is no consensus which of these methods is the most accurate. To compare four different non-invasive methods for the determination of the VAT via respiratory gas exchange analysis during a cardiopulmonary exercise test (CPET). A secondary objective is to determine the interobserver reliability of the VAT. CPET data of 30 children diagnosed with either cystic fibrosis (CF; N = 15) or with a surgically corrected dextro-transposition of the great arteries (asoTGA; N = 15) were included. No significant differences were found between conditions or among testers. The RER = 1 method differed the most compared to the other methods, showing significant higher results in all six variables. The PET-O2 method differed significantly on five of six and four of six exercise variables with the V-slope method and the VentEq method, respectively. The V-slope and the VentEq method differed significantly on one of six exercise variables. Ten of thirteen ICCs that were >0.80 had a 95% CI > 0.70. The RER = 1 method and the V-slope method had the highest number of significant ICCs and 95% CIs. The V-slope method, the ventilatory equivalent method and the PET-O2 method are comparable and reliable methods to determine the VAT during CPET in children with CF or asoTGA. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Six-minute walking test in children with ESRD: discrimination validity and construct validity.
Takken, Tim; Engelbert, Raoul; van Bergen, Monique; Groothoff, Jaap; Nauta, Jeroen; van Hoeck, Koen; Lilien, Marc; Helders, Paul
2009-11-01
The six-minute walking test (6MWT) may be a practical test for the evaluation functional exercise capacity in children with end-stage renal disease (ESRD). The aim of this study was to investigate the 6MWT performance in children with ESRD compared to reference values obtained in healthy children and, secondly, to study the relationship between 6MWT performance with anthropometric variables, clinical parameters, aerobic capacity and muscle strength. Twenty patients (13 boys and seven girls; mean age 14.1 +/- 3.4 years) on dialysis participated in this study. Anthropometrics were taken in a standardized manner. The 6MWT was performed in a 20-m-long track in a straight hallway. Aerobic fitness was measured using a cycle ergometer test to determine peak oxygen uptake (V O(2peak)), peak rate (W(peak)) and ventilatory threshold (VT). Muscle strength was measured using hand-held myometry. Children with ESRD showed a reduced 6MWT performance (83% of predicted, p < 0.0001), irrespective of the reference values used. The strongest predictors of 6MWT performance were haematocrit and height. Regression models explained 59% (haematocrit and height) to 60% (haematocrit) of the variance in 6MWT performance. 6MWT performance was not associated with V O(2peak), strength, or other anthropometric variables, but it was significantly associated with haematocrit and height. Children with ESRD scored lower on the 6MWT than healthy children. Based on these results, the 6MWT may be a useful instrument for monitoring clinical status in children with ESRD, however it cannot substitute for other fitness tests, such as a progressive exercise test to measure V O(2peak) or muscle strength tests.
Kumaresan, Yogeenth; Pak, Yusin; Lim, Namsoo; Lee, Ryeri; Song, Hui; Kim, Tae Heon; Choi, Boran; Jung, Gun Young
2016-06-01
We demonstrated the effect of active layer (channel) thickness and annealing temperature on the electrical performances of Ga2O3-In2O3-ZnO (GIZO) thin film transistor (TFT) having nanoscale channel width (W/L: 500 nm/100 μm). We found that the electron carrier concentration of the channel was decreased significantly with increasing the annealing temperature (100 degrees C to 300 degrees C). Accordingly, the threshold voltage (V(T)) was shifted towards positive voltage (-12.2 V to 10.8 V). In case of channel thickness, the V(T) was shifted towards negative voltage with increasing the channel thickness. The device with channel thickness of 90 nm annealed at 200 degrees C revealed the best device performances in terms of mobility (10.86 cm2/Vs) and V(T) (0.8 V). The effect of channel length was also studied, in which the channel width, thickness and annealing temperature were kept constant such as 500 nm, 90 nm and 200 degrees C, respectively. The channel length influenced the on-current level significantly with small variation of V(T), resulting in lower value of on/off current ratio with increasing the channel length. The device with channel length of 0.5 μm showed enhanced on/off current ratio of 10(6) with minimum V(T) of 0.26 V.
Gläser, Sven; Ittermann, Till; Koch, Beate; Schäper, Christoph; Felix, Stephan B; Völzke, Henry; Könemann, Raik; Ewert, Ralf; Hansen, James E
2013-06-01
Besides exercise intolerance, the assessment of ventilatory and perfusion adequacy allows additional insights in the disease pathophysiology in many cardiovascular or pulmonary diseases. Valid measurements of dead space/tidal volume ratios (VD/VT), arterial (a') - end-tidal (et) carbon dioxide (CO2) and oxygen (O2) pressure differences (p(a'-et)CO2) and (p(et-a')O2), and alveolar (A)-a' O2 pressure differences (p(A-a')O2) require using blood samples in addition to gas exchange analyses on a breath-by-breath-basis. Smoking and nutritional status are also important factors in defining disorders. Using a large healthy population we considered the impact of these factors to develop useful prediction equations. Incremental cycle exercise protocols were applied to apparently healthy volunteer adults who did not have structural heart disease or echocardiographic or lung function pathologies. Age, height, weight, and smoking were analysed for their influence on the target parameters in each gender. Reference values were determined by regression analyses. The final study sample consisted of 476 volunteers (190 female), aged 25-85 years. Smoking significantly influences p(A-a')O2 and p(a'-et)CO2 at rest and peak exercise, and VD/VT during exercise. Obesity influences upper limits of VD/VT, p(a'-et)CO2 and p(et-a')O2 at rest as well as p(A-a')O2 and p(et-a')O2 at exercise. Reference equations for never-smokers as well as for apparently healthy smokers considering influencing factors are given. Gender, age, height, weight, and smoking significantly influence gas exchange. Considering all of these factors this study provides a comprehensive set of reference equations derived from a large number of participants of a population-based study. Copyright © 2013 Elsevier Ltd. All rights reserved.
Janardhan, Ajit H; Li, Wenwen; Fedorov, Vadim V; Yeung, Michael; Wallendorf, Michael J; Schuessler, Richard B; Efimov, Igor R
2012-12-11
The authors sought to develop a low-energy electrotherapy that terminates ventricular tachycardia (VT) when antitachycardia pacing (ATP) fails. High-energy implantable cardioverter-defibrillator (ICD) shocks are associated with device failure, significant morbidity, and increased mortality. A low-energy alternative to ICD shocks is desirable. Myocardial infarction was created in 25 dogs. Sustained, monomorphic VT was induced by programmed stimulation. Defibrillation electrodes were placed in the right ventricular apex, and coronary sinus and left ventricular epicardium. If ATP failed to terminate sustained VT, the defibrillation thresholds (DFTs) of standard versus experimental electrotherapies were measured. Sustained VT ranged from 276 to 438 beats/min (mean 339 beats/min). The right ventricular-coronary sinus shock vector had lower impedance than the right ventricular-left ventricular patch (54.4 ± 18.1 Ω versus 109.8 ± 16.9 Ω; p < 0.001). A single shock required between 0.3 ± 0.2 J to 5.9 ± 2.5 J (mean 2.64 ± 3.22 J; p = 0.008) to terminate VT, and varied depending upon the phase of the VT cycle in which it was delivered. By contrast, multiple shocks delivered within 1 VT cycle length were not phase dependent and achieved lower DFT compared with a single shock (0.13 ± 0.09 J for 3 shocks, 0.08 ± 0.04 J for 5 shocks, and 0.09 ± 0.07 J for 7 shocks; p < 0.001). Finally, a multistage electrotherapy (MSE) achieved significantly lower DFT compared with a single biphasic shock (0.03 ± 0.05 J versus 2.37 ± 1.20 J; respectively, p < 0.001). At a peak shock amplitude of 20 V, MSE achieved 91.3% of terminations versus 10.5% for a biphasic shock (p < 0.001). MSE achieved a major reduction in DFT compared with a single biphasic shock for ATP-refractory monomorphic VT, and represents a novel electrotherapy to reduce high-energy ICD shocks. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J
2016-01-01
Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP-root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. All criteria for feasibility were achieved. Mean V'O2peak was 106±9% of predicted V'O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V'O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V'O2max, and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training.
Ellis, Lindsay A; Ainslie, Philip N; Armstrong, Victoria A; Morris, Laura E; Simair, Ryan G; Sletten, Nathan R; Tallon, Christine M; McManus, Ali M
2017-06-01
Little is known about the response of the cerebrovasculature to acute exercise in children and how these responses might differ with adults. Therefore, we compared changes in middle cerebral artery blood velocity (MCAV mean ), end-tidal Pco 2 ([Formula: see text]), blood pressure, and minute ventilation (V̇e) in response to incremental exercise between children and adults. Thirteen children [age: 9 ± 1 (SD) yr] and thirteen sex-matched adults (age: 25 ± 4 yr) completed a maximal exercise test, during which MCAV mean , [Formula: see text], and V̇e were measured continuously. These variables were measured at rest, at exercise intensities specific to individual ventilatory thresholds, and at maximum. Although MCAV mean was higher at rest in children compared with adults, there were smaller increases in children (1-12%) compared with adults (12-25%) at all exercise intensities. There were alterations in [Formula: see text] with exercise intensity in an age-dependent manner [ F (2.5,54.5) = 7.983, P < 0.001; η 2 = 0.266], remaining stable in children with increasing exercise intensity (37-39 mmHg; P > 0.05) until hyperventilation-induced reductions following the respiratory compensation point. In adults, [Formula: see text] increased with exercise intensity (36-45 mmHg, P < 0.05) until the ventilatory threshold. From the ventilatory threshold to maximum, adults showed a greater hyperventilation-induced hypocapnia than children. These findings show that the relative increase in MCAV mean during exercise was attenuated in children compared with adults. There was also a weaker relationship between MCAV mean and [Formula: see text] during exercise in children, suggesting that cerebral perfusion may be regulated by different mechanisms during exercise in the child. NEW & NOTEWORTHY These findings provide the first direct evidence that exercise increases cerebral blood flow in children to a lesser extent than in adults. Changes in end-tidal CO 2 parallel changes in cerebral perfusion in adults but not in children, suggesting age-dependent regulatory mechanisms of cerebral blood flow during exercise. Copyright © 2017 the American Physiological Society.
Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J.
2016-01-01
Background Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Methods Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP−root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. Results All criteria for feasibility were achieved. Mean V′O2peak was 106±9% of predicted V′O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V′O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). Conclusions RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V′O2max, and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training. PMID:26849137
Separation of β-amyloid binding and white matter uptake of 18F-flutemetamol using spectral analysis
Heurling, Kerstin; Buckley, Christopher; Vandenberghe, Rik; Laere, Koen Van; Lubberink, Mark
2015-01-01
The kinetic components of the β-amyloid ligand 18F-flutemetamol binding in grey and white matter were investigated through spectral analysis, and a method developed for creation of parametric images separating grey and white matter uptake. Tracer uptake in grey and white matter and cerebellar cortex was analyzed through spectral analysis in six subjects, with (n=4) or without (n=2) apparent β-amyloid deposition, having undergone dynamic 18F-flutemetamol scanning with arterial blood sampling. The spectra were divided into three components: slow, intermediate and fast basis function rates. The contribution of each of the components to total volume of distribution (VT) was assessed for different tissue types. The slow component dominated in white matter (average 90%), had a higher contribution to grey matter VT in subjects with β-amyloid deposition (average 44%) than without (average 6%) and was absent in cerebellar cortex, attributing the slow component of 18F-flutemetamol uptake in grey matter to β-amyloid binding. Parametric images of voxel-based spectral analysis were created for VT, the slow component and images segmented based on the slow component contribution; confirming that grey matter and white matter uptake can be discriminated on voxel-level using a threshold for the contribution from the slow component to VT. PMID:26550542
Temporal and voltage stress stability of high performance indium-zinc-oxide thin film transistors
NASA Astrophysics Data System (ADS)
Song, Yang; Katsman, Alexander; Butcher, Amy L.; Paine, David C.; Zaslavsky, Alexander
2017-10-01
Thin film transistors (TFTs) based on transparent oxide semiconductors, such as indium zinc oxide (IZO), are of interest due to their improved characteristics compared to traditional a-Si TFTs. Previously, we reported on top-gated IZO TFTs with an in-situ formed HfO2 gate insulator and IZO active channel, showing high performance: on/off ratio of ∼107, threshold voltage VT near zero, extracted low-field mobility μ0 = 95 cm2/V·s, and near-perfect subthreshold slope at 62 mV/decade. Since device stability is essential for technological applications, in this paper we report on the temporal and voltage stress stability of IZO TFTs. Our devices exhibit a small negative VT shift as they age, consistent with an increasing carrier density resulting from an increasing oxygen vacancy concentration in the channel. Under gate bias stress, freshly annealed TFTs show a negative VT shift during negative VG gate bias stress, while aged (>1 week) TFTs show a positive VT shift during negative VG stress. This indicates two competing mechanisms, which we identify as the field-enhanced generation of oxygen vacancies and the field-assisted migration of oxygen vacancies, respectively. A simplified kinetic model of the vacancy concentration evolution in the IZO channel under electrical stress is provided.
The effect of mouth leak and humidification during nasal non-invasive ventilation.
Tuggey, Justin M; Delmastro, Monica; Elliott, Mark W
2007-09-01
Poor mask fit and mouth leak are associated with nasal symptoms and poor sleep quality in patients receiving domiciliary non-invasive ventilation (NIV) through a nasal mask. Normal subjects receiving continuous positive airways pressure demonstrate increased nasal resistance following periods of mouth leak. This study explores the effect of mouth leak during pressure-targeted nasal NIV, and whether this results in increased nasal resistance and consequently a reduction in effective ventilatory support. A randomised crossover study of 16 normal subjects was performed on separate days. Comparison was made of the effect of 5 min of mouth leak during daytime nasal NIV with and without heated humidification. Expired tidal volume (V(T)), nasal resistance (R(N)), and patient comfort were measured. Mean change (Delta) in V(T) and R(N) were significantly less following mouth leak with heated humidification compared to the without (DeltaV(T) -36+/-65 ml vs. -88+/-50 ml, p<0.001; DeltaR(N) +0.9+/-0.4 vs. +2.0+/-0.7 cm H(2)O l s(-1), p<0.001). Baseline comfort was worse without humidification (5.3+/-0.4 vs. 6.2+/-0.4, p<0.01), and only deteriorated following mouth leak without humidification. In normal subjects, heated humidification during nasal NIV attenuates the adverse effects of mouth leak on effective tidal volume, nasal resistance and improves overall comfort. Heated humidification should be considered as part of an approach to patients who are troubled with nasal symptoms, once leak has been minimised.
Anaerobic Threshold and Salivary α-amylase during Incremental Exercise.
Akizuki, Kazunori; Yazaki, Syouichirou; Echizenya, Yuki; Ohashi, Yukari
2014-07-01
[Purpose] The purpose of this study was to clarify the validity of salivary α-amylase as a method of quickly estimating anaerobic threshold and to establish the relationship between salivary α-amylase and double-product breakpoint in order to create a way to adjust exercise intensity to a safe and effective range. [Subjects and Methods] Eleven healthy young adults performed an incremental exercise test using a cycle ergometer. During the incremental exercise test, oxygen consumption, carbon dioxide production, and ventilatory equivalent were measured using a breath-by-breath gas analyzer. Systolic blood pressure and heart rate were measured to calculate the double product, from which double-product breakpoint was determined. Salivary α-amylase was measured to calculate the salivary threshold. [Results] One-way ANOVA revealed no significant differences among workloads at the anaerobic threshold, double-product breakpoint, and salivary threshold. Significant correlations were found between anaerobic threshold and salivary threshold and between anaerobic threshold and double-product breakpoint. [Conclusion] As a method for estimating anaerobic threshold, salivary threshold was as good as or better than determination of double-product breakpoint because the correlation between anaerobic threshold and salivary threshold was higher than the correlation between anaerobic threshold and double-product breakpoint. Therefore, salivary threshold is a useful index of anaerobic threshold during an incremental workload.
NASA Astrophysics Data System (ADS)
Zhong, Donglai; Zhao, Chenyi; Liu, Lijun; Zhang, Zhiyong; Peng, Lian-Mao
2018-04-01
In this letter, we report a gate engineering method to adjust threshold voltage of carbon nanotube (CNT) based field-effect transistors (FETs) continuously in a wide range, which makes the application of CNT FETs especially in digital integrated circuits (ICs) easier. Top-gated FETs are fabricated using solution-processed CNT network films with stacking Pd and Sc films as gate electrodes. By decreasing the thickness of the lower layer metal (Pd) from 20 nm to zero, the effective work function of the gate decreases, thus tuning the threshold voltage (Vt) of CNT FETs from -1.0 V to 0.2 V. The continuous adjustment of threshold voltage through gate engineering lays a solid foundation for multi-threshold technology in CNT based ICs, which then can simultaneously provide high performance and low power circuit modules on one chip.
Respiratory system mechanics in acute respiratory distress syndrome.
Kallet, Richard H; Katz, Jeffrey A
2003-09-01
Respiratory mechanics research is important to the advancement of ARDS management. Twenty-eight years ago, research on the effects of PEEP and VT indicated that the lungs of ARDS patients did not behave in a manner consistent with homogenously distributed lung injury. Both Suter and colleagues] and Katz and colleagues reported that oxygenation continued to improve as PEEP increased (suggesting lung recruitment), even though static Crs decreased and dead-space ventilation increased (suggesting concurrent lung overdistension). This research strongly suggested that without VT reduction, the favorable effects of PEEP on lung recruitment are offset by lung overdistension at end-inspiration. The implications of these studies were not fully appreciated at that time, in part because the concept of ventilator-associated lung injury was in its nascent state. Ten years later. Gattinoni and colleagues compared measurements of static pressure-volume curves with FRC and CT scans of the chest in ARDS. They found that although PEEP recruits collapsed (primarily dorsal) lung segments, it simultaneously causes overdistension of non-dependent, inflated lung regions. Furthermore, the specific compliance of the aerated, residually healthy lung tissue is essentially normal. The main implication of these findings is that traditional mechanical ventilation practice was injecting excessive volumes of gas into functionally small lungs. Therefore, the emblematic low static Crs measured in ARDS reflects not only surface tension phenomena and recruitment of collapsed airspaces but also overdistension of the remaining healthy lung. The studies reviewed in this article support the concept that lung injury in ARDS is heterogeneously distributed, with resulting disparate mechanical stresses, and indicate the additional complexity from alterations in chest wall mechanics. Most of these studies, however, were published before lung-protective ventilation. Therefore, further studies are needed to refine the understanding of the mechanical effects of lung-protective ventilation. Although low-VT ventilation is becoming a standard of care for ARDS patients, many issues remain unresolved; among them are the role of PEEP and recruitment maneuvers in either preventing or promoting lung injury and the effects of respiratory rate and graded VT reduction on mechanical stress in the lungs. The authors believe that advances in mechanical ventilation that may further improve patient outcomes are likely to come from more sophisticated monitoring capabilities (ie, the ability to measure P1 or perhaps Cslice) than from the creation of new modes of ventilatory support.
Low-Voltage InGaZnO Thin Film Transistors with Small Sub-Threshold Swing.
Cheng, C H; Chou, K I; Hsu, H H
2015-02-01
We demonstrate a low-voltage driven, indium-gallium-zinc oxide thin-film transistor using high-κ LaAlO3 gate dielectric. A low VT of 0.42 V, very small sub-threshold swing of 68 mV/dec, field-effect mobility of 4.1 cm2/Ns and low operation voltage of 1.4 V were reached simultaneously in LaAlO3/IGZO TFT device. This low-power and small SS TFT has the potential for fast switching speed and low power applications.
Hopker, J G; Jobson, S A; Pandit, J J
2011-02-01
This article reviews the notion of the 'anaerobic threshold' in the context of cardiopulmonary exercise testing. Primarily, this is a review of the proposed mechanisms underlying the ventilatory and lactate response to incremental exercise, which is important to the clinical interpretation of an exercise test. Since such tests are often conducted for risk stratification before major surgery, a failure to locate or justify the existence of an anaerobic threshold will have some implications for clinical practice. We also consider alternative endpoints within the exercise response that might be better used to indicate a patient's capacity to cope with the metabolic demands encountered both during and following major surgery. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.
Factors affecting the response to exercise in patients with severe pulmonary arterial hypertension.
Flox-Camacho, Angela; Escribano-Subías, Pilar; Jiménez-López Guarch, Carmen; Fernández-Vaquero, Almudena; Martín-Ríos, Dolores; de la Calzada-Campo, Carlos Sáenz
2011-01-01
Ergospirometry objectively quantifies exercise capacity. Up until now, the response to exercise evaluated by ergospirometry in patients with pulmonary arterial hypertension has only been described in recently diagnosed.patients. Our aim is to describe the response to exercise in patients with severe pulmonary arterial hypertension under specific treatment and define which parameters determine their exercise capacity. A cross-sectional study was performed on 80 patients, 57 women, aged 45 (14), with severe pulmonary arterial hypertension (48 idiopathic, 14 related to toxic rapeseed oil, 13 to connective tissue disease, 5 to human immunodeficiency virus), mean pulmonary pressure at diagnosis 61(15)mmHg and after 49(33) months under treatment since diagnosis. Biomarkers were measured and echocardiography and ergospirometry were performed the same day. Our patients, under specific treatment, showed the typical behaviour of patients with pulmonary arterial hypertension with less limitation of both aerobic capacity and ventilatory efficiency. Being male (p=0.004), high ventilatory equivalent for carbon dioxide at anaerobic threshold (p<0.001) or biomarkers (p=0.006) were the strongest predictors of impaired peak oxygen uptake in multivariate analysis, whereas for an impaired percentage achieved of predicted value were right ventricle diastolic diameter (p<0.001), months of treatment (p=0.01) and high ventilatory equivalent for CO(2) (p<0.001). In pulmonary arterial hypertension, right ventricle dysfunction (expressed by its dilation or high NTproBNP) and impaired ventilatory inefficiency as well as being male or a short time under treatment can be considered as determining factors of impaired exercise capacity. Copyright © 2010 SEPAR. Published by Elsevier Espana. All rights reserved.
Lack of ventilatory threshold in patients with chronic obstructive pulmonary disease.
Midorikawa, J; Hida, W; Taguchi, O; Okabe, S; Kurosawa, H; Mizusawa, A; Ogawa, H; Ebihara, S; Kikuchi, Y; Shirato, K
1997-01-01
We investigated whether the ventilatory threshold (VET) could be detected in 25 patients with severe chronic obstructive pulmonary disease (COPD). Exercise on a treadmill was performed until symptom-limited maximum oxygen uptake (VO2SL) was obtained. VET was absent in 14 patients (56%, VET(-) group) and present in the others (44%, VET(+) group). Basal pulmonary functions and dyspnea index (VE,SL/MVV) were not different between the two groups. Endurance time and exercise tolerance (VO2SL/bw) were significantly less in VET(-) than in VET(+). In the former group, PaO2 and pH at maximal exercise decreased and PaCO2 increased significantly, but HCO3- did not change compared with the corresponding values before exercise. In the latter group, PaCO2 at maximal exercise increased significantly, and pH and HCO3- decreased significantly compared with the values before exercise, but PaO2 did not. The changes in PaO2 and PaCO2 were not different between the two groups, but changes in pH and HCO3- in VET(+) were greater than those in VET(-). These results suggest that the absence of VET in some COPD patients indicates a lower exercise capacity without producing metabolic acidosis. This may be caused by rapidly developing dyspnea.
Jensen, Andrew E; Palombo, Laura J; Niederberger, Brenda; Turcotte, Lorraine P; Kelly, Karen R
2016-04-01
Aerobic exercise with blood flow restriction (aBFR) has been proposed as an adjunctive modality in numerous populations, potentially via an enhanced growth factor response. However, the effects of aBFR on highly trained warfighters have yet to be examined. The purpose of this study was to determine if adjunctive aBFR as part of a regular physical training regimen would increase markers of aerobic fitness and muscle strength in elite warfighters. In addition, we sought to determine whether the changes in blood lactate concentration induced by aBFR would be associated with alterations in the insulin-like growth factor (IGF) axis. Active-duty US Naval Special Warfare Operators (n=18, age=36.8 ± 2.2 years, weight=89.1 ± 1.2 kg, height=181.5 ± 1.4 cm) from Naval Amphibious Base Coronado were recruited to participate in 20 days of adjunctive aBFR training. Peak oxygen consumption (VO2 peak), ventilatory threshold (VT), and 1-repetition max (1-RM) bench press and squat were assessed pre- and post-aBFR training. Blood lactate and plasma IGF-1 and IGF-binding protein-3 (IGFBP-3) were assessed pre-, 2 min post-, and 30 min post-aBFR on days 1, 9, and 20 of aBFR training. Following aBFR training there were no changes in VO2 peak or VT, but there was an increase in the 1-RM for the bench press and the squat (5.0 and 3.9%, respectively, P<0.05). Blood lactate concentration at the 2-min post-exercise time point was 4.5-7.2-fold higher than pre-exercise levels on all days (P<0.001). At the 30-min post-exercise time point, blood lactate was still 1.6-2.6-fold higher than pre-exercise levels (P<0.001), but had decreased by 49-56% from the 2-min post-exercise time point (P<0.001). Plasma IGF-1 concentrations did not change over the course of the study. On day 9, plasma IGFBP-3 concentration was 4-22% lower than on day 1 (P<0.01) and 22% lower on day 9 than on day 20 at the 30-min post-exercise time point (P<0.001). Our data suggest that aBFR training does not lead to practical strength adaptations or alterations in the IGF axis in a population of highly trained warfighters. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Liao, Po-Yung; Chang, Ting-Chang; Su, Wan-Ching; Chen, Bo-Wei; Chen, Li-Hui; Hsieh, Tien-Yu; Yang, Chung-Yi; Chang, Kuan-Chang; Zhang, Sheng-Dong; Huang, Yen-Yu; Chang, Hsi-Ming; Chiang, Shin-Chuan
2017-06-01
This letter investigates repeated uniaxial mechanical stress-induced degradation behavior in flexible amorphous In-Ga-Zn-O thin-film transistors (TFTs) of different geometric structures. Two types of via-contact structure TFTs are investigated: symmetrical and UI structure (TFTs with I- and U-shaped asymmetric electrodes). After repeated mechanical stress, I-V curves for the symmetrical structure show a significant negative threshold voltage (VT) shift, due to mechanical stress-induced oxygen vacancy generation. However, degradation in the UI structure TFTs after stress is a negative VT shift along with the parasitic transistor characteristic in the forward-operation mode, with this hump not evident in the reverse-operation mode. This asymmetrical degradation is clarified by the mechanical strain simulation of the UI TFTs.
Day, John D; Doshi, Rahul N; Belott, Peter; Birgersdotter-Green, Ulrika; Behboodikhah, Mahnaz; Ott, Peter; Glatter, Kathryn A; Tobias, Serge; Frumin, Howard; Lee, Byron K; Merillat, John; Wiener, Isaac; Wang, Samuel; Grogin, Harlan; Chun, Sung; Patrawalla, Rob; Crandall, Brian; Osborn, Jeffrey S; Weiss, J Peter; Lappe, Donald L; Neuman, Stacey
2007-05-08
Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations) is the first large, multicenter, prospective trial comparing vulnerability safety margin testing versus defibrillation safety margin testing with a single VF induction/defibrillation. A total of 426 patients receiving an implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator underwent vulnerability safety margin or defibrillation safety margin screening at 14 J in a randomized order. After this, patients underwent confirmatory testing, which required 2 VF conversions without failure at < or = 21 J. Patients who passed their first 14-J and confirmatory tests, irrespective of the results of their second 14-J test, had their devices programmed to a 21-J shock for ventricular tachycardia (VT) or VF > or = 200 bpm and were followed up for 1 year. Of 420 patients who underwent 14-J vulnerability safety margin screening, 322 (76.7%) passed. Of these, 317 (98.4%) also passed 21-J confirmatory tests. Of 416 patients who underwent 14-J defibrillation safety margin screening, 343 (82.5%) passed, and 338 (98.5%) also passed 21-J confirmatory tests. Most clinical VT/VF episodes (32 of 37, or 86%) were terminated by the first shock, with no difference in first shock success. In all observed cases in which the first shock was unsuccessful, subsequent shocks terminated VT/VF without complication. Although spontaneous episodes of fast VT/VF were limited, there was no difference in the odds of first shock efficacy between groups. Screening with vulnerability safety margin or defibrillation safety margin may allow for inductionless or limited shock testing in most patients.
Ertl, Peter; Kruse, Annika; Tilp, Markus
2016-10-01
The aim of the current paper was to systematically review the relevant existing electromyographic threshold concepts within the literature. The electronic databases MEDLINE and SCOPUS were screened for papers published between January 1980 and April 2015 including the keywords: neuromuscular fatigue threshold, anaerobic threshold, electromyographic threshold, muscular fatigue, aerobic-anaerobictransition, ventilatory threshold, exercise testing, and cycle-ergometer. 32 articles were assessed with regard to their electromyographic methodologies, description of results, statistical analysis and test protocols. Only one article was of very good quality. 21 were of good quality and two articles were of very low quality. The review process revealed that: (i) there is consistent evidence of one or two non-linear increases of EMG that might reflect the additional recruitment of motor units (MU) or different fiber types during fatiguing cycle ergometer exercise, (ii) most studies reported no statistically significant difference between electromyographic and metabolic thresholds, (iii) one minute protocols with increments between 10 and 25W appear most appropriate to detect muscular threshold, (iv) threshold detection from the vastus medialis, vastus lateralis, and rectus femoris is recommended, and (v) there is a great variety in study protocols, measurement techniques, and data processing. Therefore, we recommend further research and standardization in the detection of EMGTs. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Devynck, M.; Tardy, P.; Wantz, G.; Nicolas, Y.; Hirsch, L.
2011-12-01
The effect of OTS (octadecyltrichlorosilane) Self-Assembled Monolayer (SAM) grafted on SiO2 gate dielectric of pentacene-based OFETs (organic field-effect transistors) is investigated. A significant improvement of the charge mobility (μ), up to 0.74 cm2/V s, is reached thanks to OTS treatment. However, in spite of improved performances, several drawbacks, such as an increase in mobility dispersion, substantial hysteresis in IDS-VG characteristics and high threshold voltages (VT), are observed. Changing solvent and deposition method turns out to have no significant effect on the mobility dispersion. A more accurate approach on the evolution of the mobility and the threshold voltage dispersion with OTS storage time highlights the effect of the OTS solution aging. Even if no difference is evidenced in the surface energy and roughness of the OTS layer, electrical characteristics exhibit considerable deterioration with OTS solution storage time. Using an "aged" OTS solution, opened under air, kept under argon and distilled before use, results in an increase of the IDS-VG hysteresis as well as in VT and in mobility dispersion. In comparison, fresh-OTS-based OFETs present a very low hysteresis, a threshold voltage close to 0 and a much lower mobility dispersion. It is demonstrated that aged OTS solutions contain impurities that are not removed by distillation process, which leads to a less densely packed layer causing interfacial charge traps thus deteriorated performances.
Anaerobic threshold: review of the concept and directions for future research.
Davis, J A
1985-02-01
Although the term anaerobic threshold was introduced 20 years ago, the concept that an exercise-induced lactic acidosis occurs at a particular oxygen uptake which varies among subjects is over 50 years old. The surge of new interest in the parameter relates to its strong relationship to prolonged exercise performance. The average marathon running speed has been shown to be closely related to the running speed at the anaerobic threshold. Numerous studies have shown that the parameter can be validly measured during incremental exercise from the gas exchange consequences of the increased carbon dioxide and hydrogen ion levels in blood resulting from bicarbonate buffering of lactic acid. Refinement of the noninvasive detection scheme has made the parameter attractive to investigators in preventative, rehabilitative, and occupational medicine and to researchers in the exercise sciences. Controversy exists regarding the specific cause for the onset of exercise-induced metabolic acidosis. As experimentation continues to unravel the mechanisms of lactate production and ventilatory control during exercise, the anaerobic threshold concept can be further evaluated.
Through thick and thin: tuning the threshold voltage in organic field-effect transistors.
Martínez Hardigree, Josué F; Katz, Howard E
2014-04-15
Organic semiconductors (OSCs) constitute a class of organic materials containing densely packed, overlapping conjugated molecular moieties that enable charge carrier transport. Their unique optical, electrical, and magnetic properties have been investigated for use in next-generation electronic devices, from roll-up displays and radiofrequency identification (RFID) to biological sensors. The organic field-effect transistor (OFET) is the key active element for many of these applications, but the high values, poor definition, and long-term instability of the threshold voltage (V(T)) in OFETs remain barriers to realization of their full potential because the power and control circuitry necessary to compensate for overvoltages and drifting set points decrease OFET practicality. The drifting phenomenon has been widely observed and generally termed "bias stress." Research on the mechanisms responsible for this poor V(T) control has revealed a strong dependence on the physical order and chemical makeup of the interfaces between OSCs and adjacent materials in the OFET architecture. In this Account, we review the state of the art for tuning OFET performance via chemical designs and physical processes that manipulate V(T). This parameter gets to the heart of OFET operation, as it determines the voltage regimes where OFETs are either ON or OFF, the basis for the logical function of the devices. One obvious way to decrease the magnitude and variability of V(T) is to work with thinner and higher permittivity gate dielectrics. From the perspective of interfacial engineering, we evaluate various methods that we and others have developed, from electrostatic poling of gate dielectrics to molecular design of substituted alkyl chains. Corona charging of dielectric surfaces, a method for charging the surface of an insulating material using a constant high-voltage field, is a brute force means of shifting the effective gate voltage applied to a gate dielectric. A gentler and more direct method is to apply surface voltage to dielectric interfaces by direct contact or postprocess biasing; these methods could also be adapted for high throughput printing sequences. Dielectric hydrophobicity is an important chemical property determining the stability of the surface charges. Functional organic monolayers applied to dielectrics, using the surface attachment chemistry made available from "self-assembled" monolayer chemistry, provide local electric fields without any biasing process at all. To the extent that the monolayer molecules can be printed, these are also suitable for high throughput processes. Finally, we briefly consider V(T) control in the context of device integration and reliability, such as the role of contact resistance in affecting this parameter.
The Effects of Acute Exercise on Memory and Brain-Derived Neurotrophic Factor (BDNF).
Etnier, Jennifer L; Wideman, Laurie; Labban, Jeffrey D; Piepmeier, Aaron T; Pendleton, Daniel M; Dvorak, Kelly K; Becofsky, Katie
2016-08-01
Acute exercise benefits cognition, and some evidence suggests that brain-derived neurotrophic factor (BDNF) plays a role in this effect. The purpose of this study was to explore the dose-response relationship between exercise intensity, memory, and BDNF. Young adults completed 3 exercise sessions at different intensities relative to ventilator threshold (Vt) (VO 2max , Vt - 20%, Vt + 20%). For each session, participants exercised for approximately 30 min. Following exercise, they performed the Rey Auditory Verbal Learning Test (RAVLT) to assess short-term memory, learning, and long-term memory recall. Twenty-four hours later, they completed the RAVLT recognition trial, which provided another measure of long-term memory. Blood was drawn before exercise, immediately postexercise, and after the 30-min recall test. Results indicated that long-term memory as assessed after the 24-hr delay differed as a function of exercise intensity with the largest benefits observed following maximal intensity exercise. BDNF data showed a significant increase in response to exercise; however, there were no differences relative to exercise intensity and there were no significant associations between BDNF and memory. Future research is warranted so that we can better understand how to use exercise to benefit cognitive performance.
Occlusion pressures in men rebreathing CO2 under methoxyflurane anesthesia.
Derenne, J P; Couture, J; Iscoe, S; Whitelaw, A; Milic-Emili, J
1976-05-01
The effect of general anesthesia on control of breathing was studied by CO2 rebreathing and occlusion pressure measurements in six normal human subjects under methoxyflurane anesthesia. CO2 was found to increase the amplitude of the occlusion pressure wave without changing its shape, so that CO2 responses in terms of the occlusion pressure developed 100 ms after the onset of inspiration (Po/0.1) gave results equivalent to the responses in terms of Po/1.o or any other parameter of the pressure wave. Methoxyflurane depressed the ventilatory response to CO2 but not the occlusion pressure response, implying that the most important action of the anesthetic was to increase the effective elastance of the respiratory system rather than to depress the respiratory centers. The elastance was further increased by CO2, and this mechanical change had the effect of shifting the "apneic threshold" extrapolated from the ventilatory response curve to a lower PAco2. Frequency of breathing, inspiratory and expiratory times were not altered by CO2 in anesthetized subjects.
Chien, China; Chang, Huiyi Harriet; Wu, Hsi-Yang
2015-08-01
Pediatric urinary incontinence has been proposed as a cause for adult urinary incontinence, yet animal models mimic the findings of overactive bladder more closely than dysfunctional voiding. We used the bladder reduction (BR) model to study the effects of early external urethral sphincter (EUS) dysfunction on the maturation of lower urinary tract function in neonatal and young adult rats of both sexes. To determine long-term alterations in bladder and EUS function in young adult rats caused by neonatal BR. 46 Sprague-Dawley rats underwent BR and 52 underwent sham surgery at 1 week of age. At 3, 6, and 9 weeks of life, cystometry was carried out, 8-OH-DPAT (serotonergic receptor agonist) and WAY 100,635 (serotonergic receptor antagonist) were administered intravenously. Pressure threshold (PT), volume threshold (VT), storage tonic AUC, contraction area under the curve (AUC), EUS burst amplitude and burst duration were measured at baseline and after administration of serotonergic agents. PT increased in 3-week BR females compared with shams (31.1 vs. 22.7 cm H2O, p < 0.01), in conjunction with less efficient EUS emptying, as burst amplitude was suppressed (BR 0.04 vs. sham 0.07 mV, p < 0.05). VT subsequently increased in 9-week BR females compared with shams (0.81 vs. 0.36 mL, p < 0.05). Although 3-week BR males also experienced suppressed burst amplitude (BR 0.17 vs. sham 0.28 mV, p < 0.05), they showed no difference in PT at 3 weeks or VT at 9 weeks compared with sham males. The burst amplitude returned to normal in 6- and 9-week BR animals of both sexes, confirming a spontaneous recovery of EUS function over time. The thresholds for voiding in male rats are not as sensitive to early changes in EUS function compared with female rats. The response to serotonergic agents was identical between BR and sham animals. In the female animals, 8-OH-DPAT increased storage tonic AUC and burst duration, whereas in male animals, 8-OH-DPAT increased contraction AUC, burst amplitude, and burst duration. WAY 100,635 reversed the enhancements of EUS function caused by 8-OH-DPAT. BR caused a temporary impairment of EUS emptying at 3 weeks of life, similar to dysfunctional voiding, while serotonergic agonists remained effective at enhancing EUS emptying in BR animals. Although EUS emptying spontaneously improved, the increase in VT in female young adult rats suggests that timely treatment of EUS dysfunction is required to decrease the risk of long-term bladder dysfunction. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Anaerobic Threshold: Its Concept and Role in Endurance Sport
Ghosh, Asok Kumar
2004-01-01
aerobic to anaerobic transition intensity is one of the most significant physiological variable in endurance sports. Scientists have explained the term in various ways, like, Lactate Threshold, Ventilatory Anaerobic Threshold, Onset of Blood Lactate Accumulation, Onset of Plasma Lactate Accumulation, Heart Rate Deflection Point and Maximum Lactate Steady State. But all of these have great role both in monitoring training schedule and in determining sports performance. Individuals endowed with the possibility to obtain a high oxygen uptake need to complement with rigorous training program in order to achieve maximal performance. If they engage in endurance events, they must also develop the ability to sustain a high fractional utilization of their maximal oxygen uptake (%VO2 max) and become physiologically efficient in performing their activity. Anaerobic threshold is highly correlated to the distance running performance as compared to maximum aerobic capacity or VO2 max, because sustaining a high fractional utilization of the VO2 max for a long time delays the metabolic acidosis. Training at or little above the anaerobic threshold intensity improves both the aerobic capacity and anaerobic threshold level. Anaerobic Threshold can also be determined from the speed-heart rate relationship in the field situation, without undergoing sophisticated laboratory techniques. However, controversies also exist among scientists regarding its role in high performance sports. PMID:22977357
Anaerobic threshold: its concept and role in endurance sport.
Ghosh, Asok Kumar
2004-01-01
aerobic to anaerobic transition intensity is one of the most significant physiological variable in endurance sports. Scientists have explained the term in various ways, like, Lactate Threshold, Ventilatory Anaerobic Threshold, Onset of Blood Lactate Accumulation, Onset of Plasma Lactate Accumulation, Heart Rate Deflection Point and Maximum Lactate Steady State. But all of these have great role both in monitoring training schedule and in determining sports performance. Individuals endowed with the possibility to obtain a high oxygen uptake need to complement with rigorous training program in order to achieve maximal performance. If they engage in endurance events, they must also develop the ability to sustain a high fractional utilization of their maximal oxygen uptake (%VO(2) max) and become physiologically efficient in performing their activity. Anaerobic threshold is highly correlated to the distance running performance as compared to maximum aerobic capacity or VO(2) max, because sustaining a high fractional utilization of the VO(2) max for a long time delays the metabolic acidosis. Training at or little above the anaerobic threshold intensity improves both the aerobic capacity and anaerobic threshold level. Anaerobic Threshold can also be determined from the speed-heart rate relationship in the field situation, without undergoing sophisticated laboratory techniques. However, controversies also exist among scientists regarding its role in high performance sports.
Garske, Luke A; Lal, Ravin; Stewart, Ian B; Morris, Norman R; Cross, Troy J; Adams, Lewis
2017-05-01
Chest wall strapping has been used to assess mechanisms of dyspnea with restrictive lung disease. This study examined the hypothesis that dyspnea with restriction depends principally on the degree of reflex ventilatory stimulation. We compared dyspnea at the same (iso)ventilation when added dead space provided a component of the ventilatory stimulus during exercise. Eleven healthy men undertook a randomized controlled crossover trial that compared four constant work exercise conditions: 1 ) control (CTRL): unrestricted breathing at 90% gas exchange threshold (GET); 2 ) CTRL+dead space (DS): unrestricted breathing with 0.6-l dead space, at isoventilation to CTRL due to reduced exercise intensity; 3 ) CWS: chest wall strapping at 90% GET; and 4 ) CWS+DS: chest strapping with 0.6-l dead space, at isoventilation to CWS with reduced exercise intensity. Chest strapping reduced forced vital capacity by 30.4 ± 2.2% (mean ± SE). Dyspnea at isoventilation was unchanged with CTRL+DS compared with CTRL (1.93 ± 0.49 and 2.17 ± 0.43, 0-10 numeric rating scale, respectively; P = 0.244). Dyspnea was lower with CWS+DS compared with CWS (3.40 ± 0.52 and 4.51 ± 0.53, respectively; P = 0.003). Perceived leg fatigue was reduced with CTRL+DS compared with CTRL (2.36 ± 0.48 and 2.86 ± 0.59, respectively; P = 0.049) and lower with CWS+DS compared with CWS (1.86 ± 0.30 and 4.00 ± 0.79, respectively; P = 0.006). With unrestricted breathing, dead space did not change dyspnea at isoventilation, suggesting that dyspnea does not depend on the mode of reflex ventilatory stimulation in healthy individuals. With chest strapping, dead space presented a less potent stimulus to dyspnea, raising the possibility that leg muscle work contributes to dyspnea perception independent of the ventilatory stimulus. NEW & NOTEWORTHY Chest wall strapping was applied to healthy humans to simulate restrictive lung disease. With chest wall strapping, dyspnea was reduced when dead space substituted for part of a constant exercise stimulus to ventilation. Dyspnea associated with chest wall strapping depended on the contribution of leg muscle work to ventilatory stimulation. Chest wall strapping might not be a clinically relevant model to determine whether an alternative reflex ventilatory stimulus mimics the intensity of exertional dyspnea. Copyright © 2017 the American Physiological Society.
Rodríguez, F A
2000-06-01
This study compared the cardiorespiratory response of trained swimmers to 400-m unimpeded front crawl swimming (SW), treadmill running (TR) and ergometer cycling (EC) maximal exercise tests, and evaluated the validity and specificity of a method to measure maximal aerobic power in swimming. Two series of experiments were conducted. In series A (n=15), comparisons were made between VO2peak and other cardiorespiratory variables in three maximal tests: after 400-m SW, and during incremental TR and EC. In series B, VO2 peak and related variables were measured after SW and during EC (n=33). No significant differences were observed between VO2peak and VE in the three modes of exercise, although SW values tended to be higher. After SW, maximal ventilatory response was characterized by higher tidal volumes (VT) and lower respiratory rates (fR) as compared with TR and EC. The highest heart rate values (fH) were also observed in TR, followed by EC and SW. In series B, no significant differences were observed either in peak VO2 or VE, but fH was also lower in SW. A maximal 400-m unimpeded freestyle SW test yields essentially equal or nonsignificantly higher peak VO2 and VE values than during maximal TR or EC tests in trained swimmers. The specific maximal cardiorespiratory response to the SW test is characterized by higher VT, lower fR, and lower fH. Breath-by-breath measurements during the immediate recovery after a 400-m voluntary maximal swim is proposed as a valid and specific test for directly measuring maximal metabolic parameters and evaluating specific maximal aerobic power in swimming.
Individuality of breathing during volitional moderate hyperventilation.
Besleaga, Tudor; Blum, Michaël; Briot, Raphaël; Vovc, Victor; Moldovanu, Ion; Calabrese, Pascale
2016-01-01
The aim of this study is to investigate the individuality of airflow shapes during volitional hyperventilation. Ventilation was recorded on 18 healthy subjects following two protocols: (1) spontaneous breathing (SP1) followed by a volitional hyperventilation at each subject's spontaneous (HVSP) breathing rate, (2) spontaneous breathing (SP2) followed by hyperventilation at 20/min (HV20). HVSP and HV20 were performed at the same level of hypocapnia: end tidal CO2 (FETCO2) was maintained at 1% below the spontaneous level. At each breath, the tidal volume (VT), the breath (TTOT), the inspiratory (TI) and expiratory durations, the minute ventilation, VT/TI, TI/TTOT and the airflow shape were quantified by harmonic analysis. Under different conditions of breathing, we test if the airflow profiles of the same individual are more similar than airflow profiles between individuals. Minute ventilation was not significantly different between SP1 (6.71 ± 1.64 l·min(-1)) and SP2 (6.57 ± 1.31 l·min(-1)) nor between HVSP (15.88 ± 4.92 l·min(-1)) and HV20 (15.87 ± 4.16 l·min(-1)). Similar results were obtained for FETCO2 between SP1 (5.06 ± 0.54 %) and SP2 (5.00 ± 0.51%), and HVSP (4.07 ± 0.51%) and HV20 (3.88 ± 0.42%). Only TI/TTOT remained unchanged in all four conditions. Airflow shapes were similar when comparing SP1-SP2, HVSP-HV20, and SP1-HVSP but not similar when comparing SP2-HV20. These results suggest the existence of an individuality of airflow shape during volitional hyperventilation. We conclude that volitional ventilation alike automatic breathing follows inherent properties of the ventilatory system. Registered by Pascale Calabrese on ClinicalTrials.gov, # NCT01881945.
Arrhythmogenic Risk Assessment Following Four-Week Pretreatment With Nicotine and Black Tea in Rat
Joukar, Siyavash; Sheibani, Vahid; Koushesh, Faramarz; Ghasemipoor Afshar, Elham; Ghorbani Shahrbabaki, Soodabe
2015-01-01
Background: There is the controversy concerning the main component of tobacco, which is responsible for its arrhythmogenesis. In addition, there is the lack of adequate information about the influence of combination of black tea and nicotine on heart rhythm. Objectives: This study aimed to examine whether pretreatment with black tea and nicotine could modulate the susceptibility to lethal ventricular arrhythmias. Materials and Methods: Animals were randomized to control, black tea, nicotine, and black tea plus nicotine groups. Test groups were treated with black tea brewed (orally) and nicotine (2 mg/kg, subcutaneous), alone and in combination for four weeks. On day 29, aconitine was infused intravenously for induction of cardiac arrhythmia. Results: In comparison with the control group, each of tea and nicotine significantly decreased the duration of the ventricular tachycardia (VT) plus ventricular fibrillation (VF) and the score of arrhythmia severity (P < 0.05 and P < 0.01, respectively,). The latency for the first VT event was significantly longer in the all test groups, but VF latency was significant only in tea and nicotine groups compared with control group (P < 0.05 and P < 0.01, respectively).Threshold dose of aconitine for inducing VT and VF increased in all test groups, but only VT showed a significant difference in comparison to the control group (P < 0.001). Conclusions: The findings suggest that sub-chronic consumption of nicotine or black tea alone with appropriate doses could potentially be antiarrhythmic and its combination regimen does not increase the risk of fatal ventricular arrhythmias during four-week consumption period in rats. PMID:26436072
A longitudinal study on the ammonia threshold in junior cyclists
Yuan, Y; Chan, K
2004-01-01
Objectives: To identify the effect of a one year non-specific training programme on the ammonia threshold of a group of junior cyclists and to correlate ammonia threshold with other common physiological variables. Methods: The cyclists performed tests at three time points (T1, T2, T3) during the year. Follow up tests were conducted every six months after the original test. Ammonia threshold was obtained from a graded exercise with four minute steps. Results: The relatively non-specific one year training programme was effective in inducing an increase in peak VO2 (60.6 (5.9), 65.9 (7.4), and 64.6 (6.5) ml/min/kg at T1, T2, and T3 respectively) and endurance time (18.3 (4.5), 20.1 (5.2), and 27.0 (6.1) minutes at T1, T2, and T3 respectively), but was not effective for the sprint related variables. Ammonia threshold, together with lactate threshold and ventilatory threshold, was not significantly different at the three test times. Only endurance time correlated significantly with ammonia threshold (r = 0.915, p = 0.001). Conclusions: The findings suggest that a relatively non-specific one year training programme does not modify the ammonia threshold of junior cyclists. The significant correlation between ammonia threshold and endurance time further confirms that ammonia threshold is a measure of the ability to sustain exercise at submaximal intensities. PMID:15039242
Windisch, Stephanie; Seiberl, Wolfgang; Schwirtz, Ansgar; Hahn, Daniel
2017-01-01
The aim of this study was to quantify the physical demands of a simulated firefighting circuit and to establish the relationship between job performance and endurance and strength fitness measurements. On four separate days 41 professional firefighters (39 ± 9 yr, 179.6 ± 2.3 cm, 84.4 ± 9.2 kg, BMI 26.1 ± 2.8 kg/m2) performed treadmill testing, fitness testing (strength, balance and flexibility) and a simulated firefighting exercise. The firefighting exercise included ladder climbing (20 m), treadmill walking (200 m), pulling a wire rope hoist (15 times) and crawling an orientation section (50 m). Firefighting performance during the simulated exercise was evaluated by a simple time-strain-air depletion model (TSA) taking the sum of z-transformed parameters of time to finish the exercise, strain in terms of mean heart rate, and air depletion from the breathing apparatus. Multiple regression analysis based on the TSA-model served for the identification of the physiological determinants most relevant for professional firefighting. Three main factors with great influence on firefighting performance were identified (70.1% of total explained variance): VO2peak, the time firefighter exercised below their individual ventilatory threshold and mean breathing frequency. Based on the identified main factors influencing firefighting performance we recommend a periodic preventive health screening for incumbents to monitor peak VO2 and individual ventilatory threshold. PMID:28303944
Energetics of Table Tennis and Table Tennis-Specific Exercise Testing.
Zagatto, Alessandro Moura; Leite, Jorge Vieira de Mello; Papoti, Marcelo; Beneke, Ralph
2016-11-01
To test the hypotheses that the metabolic profile of table tennis is dominantly aerobic, anaerobic energy is related to the accumulated duration and intensity of rallies, and activity and metabolic profile are interrelated with the individual fitness profile determined via table tennis-specific tests. Eleven male experienced table tennis players (22 ± 3 y, 77.6 ± 18.9 kg, 177.1 ± 8.1 cm) underwent 2 simulated table tennis matches to analyze aerobic (W OXID ) energy, anaerobic glycolytic (W BLC ) energy, and phosphocreatine breakdown (W PCr ); a table tennis-specific graded exercise test to measure ventilatory threshold and peak oxygen uptake; and an exhaustive supramaximal table tennis effort to determine maximal accumulated deficit of oxygen. W OXID , W BLC , and W PCr corresponded to 96.5% ± 1.7%, 1.0% ± 0.7%, and 2.5% ± 1.4%, respectively. W OXID was interrelated with rally duration (r = .81) and number of shots per rally (r = .77), whereas match intensity was correlated with WPCr (r = .62) and maximal accumulated oxygen deficit (r = .58). The metabolic profile of table tennis is predominantly aerobic and interrelated with the individual fitness profile determined via table tennis-specific tests. Table tennis-specific ventilatory threshold determines the average oxygen uptake and overall W OXID , whereas table tennis-specific maximal accumulated oxygen deficit indicates the ability to use and sustain slightly higher blood lactate concentration and W BLC during the match.
Safety of American Heart Association-recommended minimum exercise for desmosomal mutation carriers.
Sawant, Abhishek C; Te Riele, Anneline S J M; Tichnell, Crystal; Murray, Brittney; Bhonsale, Aditya; Tandri, Harikrishna; Judge, Daniel P; Calkins, Hugh; James, Cynthia A
2016-01-01
Endurance exercise is associated with adverse outcomes in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C). Exercise recommendations for family members remain undetermined. The purposes of this study were to determine if (1) endurance exercise (Bethesda class C) and exercise intensity (metabolic equivalent hours per year [MET-Hr/year]) increase the likelihood of fulfilling 2010 Task Force Criteria and ventricular arrhythmias/implantable cardioverter-defibrillator shock (ventricular tachycardia/ventricular fibrillation [VT/VF]), and (2) exercise restriction to the American Heart Association (AHA)-recommended minimum for healthy adults is associated with favorable outcomes of at-risk family members. Twenty-eight family members of 10 probands inheriting a PKP2 mutation were interviewed about exercise from age 10. Exercise threshold to maintain overall health was based on the 2007 AHA guidelines of a minimum 390 to 650 MET-Hr/year. After adjustment for age, sex, and family membership, both participation in endurance athletics (odds ratio [OR] 7.4, P = .03) and higher-intensity exercise (OR = 4.2, P = .004) were associated with diagnosis (n = 13). Endurance athletes were also significantly more likely to develop VT/VF (n = 6, P = .02). Family members who restricted exercise at or below the upper bound of the AHA goal (≤650 MET-Hr/year) were significantly less likely to be diagnosed (OR = 0.07, P = .002) and had no VT/VF. At diagnosis and first VT/VF, family members had accumulated 2.8-fold (P = .002) and 3.5-fold (P = .03), respectively, greater MET-Hr exercise than the AHA-recommended minimum. Those who developed VT/VF had performed particularly high-intensity exercise in adolescence compared to unaffected family members (age 10-14: P = .04; age 14-19: P = .02). The results of this study suggest restricting unaffected desmosomal mutation carriers from endurance and high-intensity athletics but potentially not from AHA-recommended minimum levels of exercise for healthy adults. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Kazimierczak, Anna; Krzyżanowski, Krystian; Wierzbowski, Robert; Ryczek, Robert; Smurzyński, Paweł; Michałkiewicz, Dariusz; Orski, Zbigniew; Gielerak, Grzegorz
2011-01-01
Exercise oscillatory ventilation (EOV) is a common pattern of breathing in heart failure (HF) patients, and indicates a poor prognosis. To investigate the effects of adaptive servoventilation (ASV) on ventilatory response during exercise. We studied 39 HF patients with left ventricular ejection fraction (LVEF) £ 45. Cardiorespiratory polygraphy, cardiopulmonary exercise testing (CPET), echocardiography, and measurement of N-terminal pro-brain natriuretic peptide (NT-proBNP) concentration were performed. Twenty patients with Cheyne-Stokes respiration and apnoea-hypopnoea index (AHI) ≥ 15/h were identified. Of these, 11 patients were successfully titrated on ASV and continued therapy. In the third month of ASV treatment, polygraphy, CPET, echocardiography, and measurement of NT-proBNP concentration were performed again. The EOV was detected at baseline in 12 (31%) HF patients, including eight (67%) who underwent ASV. The EOV was associated with significantly lower LVEF, peak oxygen uptake (VO(2)), and ventilatory anaerobic threshold (VAT), and a significantly higher left ventricular diastolic diameter (LVDD), slope of ventilatory equivalent for carbon dioxide (VE/VCO(2)), AHI, central AHI and NT-proBNP concentration. In seven patients with EOV, reversal of EOV in the third month of ASV therapy was observed; only in one patient did EOV persist (p = 0.0156). The EOV can be reversed with ASV therapy. The EOV in association with central sleep apnoea and Cheyne- -Stokes respiration (CSA/CSR) is prevalent in HF patients and correlates with severity of the disease.
Popovic, Dejana; Kumar, Nikhil; Chaudhry, Sundeep; Bagai, Akshay; Arena, Ross; Kumar, Naresh
2018-05-11
Improvements in cardiorespiratory fitness (VO2peak) post-cardiac rehabilitation (post-CR) are used to gauge therapeutic efficacy. The aim of the present study was to assess the effect of supervised CR on other cardiopulmonary exercise testing (CPX) variables, specifically those that reflect ventilatory efficiency and VO2 changes in relation to changes in work rate (WR). Patients (n = 142; mean age 63 ± 9 y; 23% female) with coronary artery disease (CAD) participated in supervised CR for 3 to 6 mo completing 60 ± 17 sessions (range: 32-96 sessions), with intensity derived from the baseline CPX. CPX was completed at baseline and post-CR on a cycle ergometer. The minimum heart rate (HR) during cycling was set 5 to 10 beats/min above the HR at ventilatory anaerobic threshold (VAT) while the maximum HR remained below the ischemic threshold observed during CPX, and this intensity was maintained for 25 min. VO2peak, peak O2 pulse, the minute ventilation/carbon dioxide production (VE/VCO2) slope, the oxygen uptake efficiency slope (OUES), and the ΔVO2/ΔWR slope were determined at baseline and post-CR. Following CR, there were significant improvements (all P < .001) in VO2peak (17.7 ± 4.7 mL/kg/min vs 20.9 ± 5.4 mL/kg/min), peak O2 pulse (11.6 ± 3.2 mL/beat vs 13.4 ± 3.6 mL/beat), VE/VCO2 slope (28.4 ± 5.3 vs 27.5 ± 4.7), OUES (1.8 ± 0.5 vs 2.0 ± 0.6), and ΔVO2/ΔWR slope (9.1 ± 1.2 mL/min/W vs 9.6 ± 1.1 mL/min/W). Key markers of ventilatory efficiency and VO2 kinetics during CPX significantly improve following CR. Expanding the list of variables assessed via CPX may provide better resolution in validation of CR therapeutic efficacy in patients with CAD.
Wang, Hongjun; Liang, Youguang; Li, Sixin; Chang, Jianbo
2013-01-01
Using 3 cyprinid fish species zebra fish, rare minnow, and juvenile grass carp, we conducted assays of lethal reaction and ventilatory response to analyze sensitivity of the fish to 4 heavy metals. Our results showed that the 96 h LC50 of Hg2+ to zebra fish, juvenile grass carp, and rare minnow were 0.14 mg L−1, 0.23 mg L−1, and 0.10 mg L−1, respectively; of Cu2+0.17 mg L−1, 0.09 mg L−1, and 0.12 mg L−1 respectively; of Cd2+6.5 mg L−1, 18.47 mg L−1, 5.36 mg L−1, respectively; and of Zn2+44.48 mg L−1, 31.37 mg L−1, and 12.74 mg L−1, respectively. Under a 1-h exposure, the ventilatory response to the different heavy metals varied. Ventilatory frequency (Vf) and amplitude (Va) increased in zebra fish, juvenile grass carp, and rare minnows exposed to Hg2+ and Cu2+ (P<0.05), and the Vf and Va of the 3 species rose initially and then declined when exposed to Cd2+. Zn2+ had markedly different toxic effects than the other heavy metals, whose Vf and Va gradually decreased with increasing exposure concentration (P<0.05). The rare minnow was the most highly susceptible of the 3 fish species to the heavy metals, with threshold effect concentrations (TEC) of 0.019 mg L−1, 0.046 mg L−1, 2.142 mg L−1, and 0.633 mg L−1 for Hg2+, Cu2+, Cd2+, and Zn2+, respectively. Therefore, it is feasible to use ventilatory parameters as a biomarker for evaluating the pollution toxicity of metals and to recognize early warning signs by using rare minnows as a sensor. PMID:23755209
Yunoki, Takahiro; Matsuura, Ryouta; Yamanaka, Ryo; Afroundeh, Roghayyeh; Lian, Chang-Shun; Shirakawa, Kazuki; Ohtsuka, Yoshinori; Yano, Tokuo
2016-06-01
Effort sense has been suggested to be involved in the hyperventilatory response during intense exercise (IE). However, the mechanism by which effort sense induces an increase in ventilation during IE has not been fully elucidated. The aim of this study was to determine the relationship between effort-mediated ventilatory response and corticospinal excitability of lower limb muscle during IE. Eight subjects performed 3 min of cycling exercise at 75-85 % of maximum workload twice (IE1st and IE2nd). IE2nd was performed after 60 min of resting recovery following 45 min of submaximal cycling exercise at the workload corresponding to ventilatory threshold. Vastus lateralis muscle response to transcranial magnetic stimulation of the motor cortex (motor evoked potentials, MEPs), effort sense of legs (ESL, Borg 0-10 scale), and ventilatory response were measured during the two IEs. The slope of ventilation (l/min) against CO2 output (l/min) during IE2nd (28.0 ± 5.6) was significantly greater than that (25.1 ± 5.5) during IE1st. Mean ESL during IE was significantly higher in IE2nd (5.25 ± 0.89) than in IE1st (4.67 ± 0.62). Mean MEP (normalized to maximal M-wave) during IE was significantly lower in IE2nd (66 ± 22 %) than in IE1st (77 ± 24 %). The difference in mean ESL between the two IEs was significantly (p < 0.05, r = -0.82) correlated with the difference in mean MEP between the two IEs. The findings suggest that effort-mediated hyperventilatory response to IE may be associated with a decrease in corticospinal excitability of exercising muscle.
Cathcart, Andrew J; Whipp, Brian J; Turner, Anthony P; Wilson, John; Ward, Susan A
2010-01-01
The ventilatory (V' E) mechanisms subserving stability of alveolar and arterial PCO2 (PACO2, PaCO2) during moderate exercise (< lactate threshold, thetaL) remain controversial. As long-term modulation has been argued to be an important contributor to this control process, we proposed that subjects with no experience of cycling (NEx) might provide insight into this issue. With no exercise familiarization, 9 sedentary NEx subjects and 9 age-, sex-, and activity-matched controls (C) who had cycled regularly for recreational purposes since childhood completed a square-wave (6-min stage) cycle-ergometry test: 10 W-WR1-WR2-WR1-10 W; WR1 range 25-45 W, WR2 range 50-90 W. WRs were subsequently confirmed to
Zhu, Ye; Gu, Xiang; Xu, Chao
2017-10-16
Implantable cardioverter defibrillators (ICD) are capable of effectively terminating malignant ventricular arrhythmia and are the most effective way to prevent sudden cardiac death. However, some evidences demonstrated that both anti-tachycardia pacing (ATP) and ICD shock can also bring adverse prognosis. A 66-year-old Han Chinese man with prior ICD implantation was admitted to our hospital because of frequent ICD shocks. Although intravenous amiodarone and esmolol succinate were administered daily, the patient suffered 155 episodes of VT/VF during 8 weeks after implantation. After repeated discharge of the device, the pacing threshold of the patient increased gradually. Considering the inappropriate increase of the pacing threshold, we decided to reposition the right ventricular (RV) lead with good sensing and threshold parameters confirmed. Subsequent 22 months interrogation follow-up revealed a stable lead position and electrical specifications. Furthermore, antiarrhythmic drugs were maximally increased, while ATP burst was remarkably decreased and the inappropriate ICD shock never occurred until now. An inappropriate pacing threshold was increased secondary to repeated ICD electrical storm. A timely active lead position adjustment reduced the pacing threshold and eliminated the risk of premature battery depletion.
Walls, Justin; Maskrey, Michael; Wood-Baker, Richard; Stedman, Wade
2002-06-01
Arterial haemoglobin saturation during exercise in healthy young women [eight subjects mean (SEM) age 20.8 (1.8) years] was measured to confirm the theory that young women experience exercise-induced arterial hypoxaemia (EIAH) at a lower relative percentage of maximal oxygen uptake (VO(2max)) than has been documented in their male counterparts. To determine if flow limitation [the percentage of the tidal volume ( V(T)) that met or exceeded the boundary established by multiple maximal expiratory manoeuvres] and/or post-exercise lung diffusing capacity are linked to EIAH in women, and to investigate the influence of exercise intensity and duration on post-exercise carbon monoxide lung diffusing capacity ( D(L, CO)), these parameters were measured during and after three exercise tests (incremental test until exhaustion, 5 km run and 5 km run with sprint). All subjects experienced physiologically significant EIAH (a fall of more than 3% in oxygen saturation of arterial blood from levels at rest) and seven subjects experienced flow limitation during the VO(2max) protocol [mean (SD) 12.2 (8.8)% of V(T)]. Even though there was no significant relationship between aerobic capacity and the degree of flow limitation ( r=0.33, P>0.05), the flow limitation was related to absolute ventilation in the subjects studied ( r=0.82, P<0.05). There was no significant relationship between decrements in post exercise D(L, CO) and EIAH ( r=0.05, P>0.05), however there was a strong correlation between the extent of flow limitation (% of V(T)) and EIAH ( r=0.71). Significant decreases in D(L, CO) lasted for up to 16 h after each of the exercise tests ( P<0.05) and lasted for a further 8 h after the maximal test ( P<0.05). Exercise intensity was the main contributing factor to the observed decreases in post-exercise D(L, CO) with the percentage of VO(2max) attained during the various tests being significantly related to the fall in D(L, CO) for 1, 2, 3, 16 and 24 h after exercise ( P<0.05). As the appearance of flow limitation closely coincided with the appearance of EIAH, the results from the present study suggest that flow limitation is a contributing factor to EIAH in women although the exact mechanism remains unclear.
Parfitt, Gaynor; Alrumh, Amnah; Rowlands, Alex V
2012-11-01
Affect-regulated exercise to feel 'good' can be used to control exercise intensity amongst both active and sedentary individuals and should support exercise adherence. It is not known, however, whether affect-regulated exercise training can lead to physical health gains. The aim of this study was to examine if affect-regulated exercise to feel 'good' leads to improved fitness over the course of an 8-week training programme. A repeated measures design (pretest-posttest) with independent groups (training and control). 20 sedentary females completed a submaximal graded exercise test and were then allocated to either a training group or control group. The training group completed two supervised sessions and one unsupervised session per week for 8 weeks. Exercise intensity was affect-regulated to feel 'good'. Following the 8 weeks of training, both groups completed a second submaximal graded exercise test. Repeated measures analyses of variance indicated a significant increase in the time to reach ventilatory threshold in the training group (318 ± 23.7s) compared to control (248 ± 16.9s). Overall compliance to training was high (>92%). Participants in the training group exercised at intensities that would be classified as being in the lower range of the recommended guidelines (≈ 50% V˙O(2) max) for cardiovascular health. Affect-regulated exercise to feel 'good' can be used in a training programme to regulate exercise intensity. This approach led to a 19% increase in time to reach ventilatory threshold, which is indicative of improved fitness. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
dos Santos, Karoliny; Gulart, Aline A.; Munari, Anelise B.; Karloh, Manuela; Mayer, Anamaria F.
2016-01-01
ABSTRACT Background Airflow limitation frequently leads to the interruption of activities of daily living (ADL) in patients with Chronic Obstructive Pulmonary Disease (COPD). These patients commonly show absence of ventilatory reserve, reduced inspiratory reserve volume, and dynamic hyperinflation (DH). Objective To investigate ventilatory response and DH induced by three ADL-based protocols in COPD patients and compare them to healthy subjects. Method Cross-sectional study. COPD group: 23 patients (65±6 years, FEV1 37.2±15.4%pred); control group: 14 healthy subjects (64±4 years) matched for age, sex, and body mass index. Both groups performed all three tests: Glittre-ADL test; an activity test that involved moving objects on a shelf (TSHELF); and a modified shelf protocol isolating activity with upper limbs (TSHELF-M). Ventilatory response and inspiratory capacity were evaluated. Results Baseline ventilatory variables were similar between groups (p>0.05). The ventilatory demand increased and the inspiratory capacity decreased significantly at the end of the tests in the COPD group. Ventilatory demand and DH were higher (p<0.05) in the TSHELF than in the TSHELF–M in the COPD group (p<0.05). There were no differences in DH between the three tests in the control group (p>0.05) and ventilatory demand increased at the end of the tests (p<0.05) but to a lower extent than the COPD group. Conclusion The TSHELF induces similar ventilatory responses to the Glittre-ADL test in COPD patients with higher ventilatory demand and DH. In contrast, the ventilatory response was attenuated in the TSHELF-M, suggesting that squatting and bending down during the Glittre-ADL test could trigger significant ventilatory overload. PMID:27333482
Combine Flash-Based FPGA TID and Long-Term Retention Reliabilities Through VT Shift
NASA Astrophysics Data System (ADS)
Wang, Jih-Jong; Rezzak, Nadia; Dsilva, Durwyn; Xue, Fengliang; Samiee, Salim; Singaraju, Pavan; Jia, James; Nguyen, Victor; Hawley, Frank; Hamdy, Esmat
2016-08-01
Reliability test results of data retention and total ionizing dose (TID) in 65 nm Flash-based field programmable gate array (FPGA) are presented. Long-chain inverter design is recommended for reliability evaluation because it is the worst case design for both effects. Based on preliminary test data, both issues are unified and modeled by one natural decay equation. The relative contributions of TID induced threshold-voltage shift and retention mechanisms are evaluated by analyzing test data.
Structure-dependent Pseudoreceptor Intracellular Traffic of Adamantyl Globotriaosyl Ceramide Mimics*
Saito, Mitsumasa; Mylvaganum, Murugespillai; Tam, Patty; Novak, Anton; Binnington, Beth; Lingwood, Clifford
2012-01-01
The verotoxin (VT) (Shiga toxin) receptor globotriaosyl ceramide (Gb3), mediates VT1/VT2 retrograde transport to the endoplasmic reticulum (ER) for cytosolic A subunit access to inhibit protein synthesis. Adamantyl Gb3 is an amphipathic competitive inhibitor of VT1/VT2 Gb3 binding. However, Gb3-negative VT-resistant CHO/Jurkat cells incorporate adaGb3 to become VT1/VT2-sensitive. CarboxyadaGb3, urea-adaGb3, and hydroxyethyl adaGb3, preferentially bound by VT2, also mediate VT1/VT2 cytotoxicity. VT1/VT2 internalize to early endosomes but not to Golgi/ER. AdabisGb3 (two deacyl Gb3s linked to adamantane) protects against VT1/VT2 more effectively than adaGb3 without incorporating into Gb3-negative cells. AdaGb3 (but not hydroxyethyl adaGb3) incorporation into Gb3-positive Vero cells rendered punctate cell surface VT1/VT2 binding uniform and subverted subsequent Gb3-dependent retrograde transport to Golgi/ER to render cytotoxicity (reduced for VT1 but not VT2) brefeldin A-resistant. VT2-induced vacuolation was maintained in adaGb3-treated Vero cells, but vacuolar membrane VT2 was lost. AdaGb3 destabilized membrane cholesterol and reduced Gb3 cholesterol stabilization in phospholipid liposomes. Cholera toxin GM1-mediated Golgi/ER targeting was unaffected by adaGb3. We demonstrate the novel, lipid-dependent, pseudoreceptor function of Gb3 mimics and their structure-dependent modulation of endogenous intracellular Gb3 vesicular traffic. PMID:22418442
Ham, Joo-ho; Park, Hun-Young; Kim, Youn-ho; Bae, Sang-kon; Ko, Byung-hoon
2017-01-01
[Purpose] The purpose of this study was to develop a regression model to estimate the heart rate at the lactate threshold (HRLT) and the heart rate at the ventilatory threshold (HRVT) using the heart rate threshold (HRT), and to test the validity of the regression model. [Methods] We performed a graded exercise test with a treadmill in 220 normal individuals (men: 112, women: 108) aged 20–59 years. HRT, HRLT, and HRVT were measured in all subjects. A regression model was developed to estimate HRLT and HRVT using HRT with 70% of the data (men: 79, women: 76) through randomization (7:3), with the Bernoulli trial. The validity of the regression model developed with the remaining 30% of the data (men: 33, women: 32) was also examined. [Results] Based on the regression coefficient, we found that the independent variable HRT was a significant variable in all regression models. The adjusted R2 of the developed regression models averaged about 70%, and the standard error of estimation of the validity test results was 11 bpm, which is similar to that of the developed model. [Conclusion] These results suggest that HRT is a useful parameter for predicting HRLT and HRVT. PMID:29036765
Ham, Joo-Ho; Park, Hun-Young; Kim, Youn-Ho; Bae, Sang-Kon; Ko, Byung-Hoon; Nam, Sang-Seok
2017-09-30
The purpose of this study was to develop a regression model to estimate the heart rate at the lactate threshold (HRLT) and the heart rate at the ventilatory threshold (HRVT) using the heart rate threshold (HRT), and to test the validity of the regression model. We performed a graded exercise test with a treadmill in 220 normal individuals (men: 112, women: 108) aged 20-59 years. HRT, HRLT, and HRVT were measured in all subjects. A regression model was developed to estimate HRLT and HRVT using HRT with 70% of the data (men: 79, women: 76) through randomization (7:3), with the Bernoulli trial. The validity of the regression model developed with the remaining 30% of the data (men: 33, women: 32) was also examined. Based on the regression coefficient, we found that the independent variable HRT was a significant variable in all regression models. The adjusted R2 of the developed regression models averaged about 70%, and the standard error of estimation of the validity test results was 11 bpm, which is similar to that of the developed model. These results suggest that HRT is a useful parameter for predicting HRLT and HRVT. ©2017 The Korean Society for Exercise Nutrition
Medication effects on sleep and breathing.
Seda, Gilbert; Tsai, Sheila; Lee-Chiong, Teofilo
2014-09-01
Sleep respiration is regulated by circadian, endocrine, mechanical and chemical factors, and characterized by diminished ventilatory drive and changes in Pao2 and Paco2 thresholds. Hypoxemia and hypercapnia are more pronounced during rapid eye movement. Breathing is influenced by sleep stage and airway muscle tone. Patient factors include medical comorbidities and body habitus. Medications partially improve obstructive sleep apnea and stabilize periodic breathing at altitude. Potential adverse consequences of medications include precipitation or worsening of disorders. Risk factors for adverse medication effects include aging, medical disorders, and use of multiple medications that affect respiration. Published by Elsevier Inc.
Parazzi, Paloma Lopes Francisco; Marson, Fernando Augusto de Lima; Ribeiro, Maria Angela Gonçalves de Oliveira; de Almeida, Celize Cruz Bresciani; Martins, Luiz Cláudio; Paschoal, Ilma Aparecida; Toro, Adyleia Aparecida Dalbo Contrera; Schivinski, Camila Isabel Santos; Ribeiro, Jose Dirceu
2015-05-19
Exercise has been studied as a prognostic marker for patients with cystic fibrosis (CF), as well as a tool for improving their quality of life and analyzing lung disease. In this context, the aim of the present study was to evaluate and compare variables of lung functioning. Our data included: (i) volumetric capnography (VCAP) parameters: expiratory minute volume (VE), volume of exhaled carbon dioxide (VCO2), VE/VCO2, ratio of dead space to tidal volume (VD/VT), and end-tidal carbon dioxide (PetCO2); (ii) spirometry parameters: forced vital capacity (FVC), percent forced expiratory volume in the first second of the FVC (FEV1%), and FEV1/FVC%; and (iii) cardiorespiratory parameters: heart rate (HR), respiratory rate, oxygen saturation (SpO2), and Borg scale rating at rest and during exercise. The subjects comprised children, adolescents, and young adults aged 6-25 years with CF (CF group [CFG]) and without CF (control group [CG]). This was a clinical, prospective, controlled study involving 128 male and female patients (64 with CF) of a university hospital. All patients underwent treadmill exercise tests and provided informed consent after study approval by the institutional ethics committee. Linear regression, Kruskal-Wallis test, and Mann-Whitney test were performed to compare the CFG and CG. The α value was set at 0.05. Patients in the CFG showed significantly different VCAP values and spirometry variables throughout the exercise test. Before, during, and after exercise, several variables were different between the two groups; statistically significant differences were seen in the spirometry parameters, SpO2, HR, VCO2, VE/VCO2, PetCO2, and Borg scale rating. VCAP variables changed at each time point analyzed during the exercise test in both groups. VCAP can be used to analyze ventilatory parameters during exercise. All cardiorespiratory, spirometry, and VCAP variables differed between patients in the CFG and CG before, during, and after exercise.
Upper airway CO2 receptors in tegu lizards: localization and ventilatory sensitivity.
Coates, E L; Ballam, G O
1987-01-01
1. Tidal volume, end-tidal CO2, and ventilatory frequency in Tupinambis nigropunctatus were measured in response to CO2 (1-4%) delivered to either the mouth or nares. Additionally, the sensitivity of the ventilatory response to nasal CO2 was evaluated at CO2 concentrations less than 1%. The ventilatory parameters were also measured in response to CO2 (1-4%) delivered to the nares after the olfactory peduncle was transected. 2. It was found that (0.4-4%) nasal CO2 depressed ventilatory frequency by 9% to 83% respectively, while tidal volume was not significantly altered. CO2 (1-4%) delivered to the mouth produced no apparent changes in any of the ventilatory parameters. Following transection of the olfactory peduncle, nasal CO2 was ineffective in producing any change in ventilatory frequency or depth. 3. These findings indicate that CO2-sensitive receptors are located in either the nasal or vomeronasal membranes of tegu lizards and that the olfactory peduncle must be intact for these receptors to affect ventilatory changes in response to elevated CO2 concentrations. The receptors are capable of mediating a ventilatory response to CO2 concentrations lower than those found in either expired air or in confined spaces such as occupied burrows. 4. The discrepancies in the ventilatory responses of lizards and snakes to inspired CO2 reported in past experiments may be partially explained by the presence of nasal or vomeronasal CO2-sensitive receptors.
Tyler, S D; Johnson, W M; Lior, H; Wang, G; Rozee, K R
1991-01-01
A set of synthetic oligonucleotide primers was designed for use in a polymerase chain reaction protocol to specifically detect the B subunit genes in vtx2ha and vtx2hb, which code for the production of the VT2 (Shiga-like toxin II) variant cytotoxins VT2v-a and VT2v-b, respectively. An additional set of primers amplified a fragment common to the B subunits of the VT2 and the VT2 variant genes. Subsequent restriction endonuclease digestion of this amplicon permitted prediction of specific VT2 and variant genotypes on the basis of predetermined restriction fragment length polymorphisms. Genotypes of 21 VT2-producing strains of Escherichia coli were determined using this polymerase chain reaction-restriction fragment length polymorphism procedure. Four strains contained B subunit target sequences only for VT2 genes, 9 strains contained sequences only for VT2v-a genes, and 3 strains contained sequences only for VT2v-b. For genes in combination, one strain contained B subunit genes for both VT2 and VT2v-a and two strains contained B subunit genes for VT2 and VT2v-b. Two strains of E. coli O91:H21 contained both VT2v-a and VT2v-b B subunit genes. The VT2 reference strain of E. coli, E32511, was found to contain the targeted sequences from both VT2 and VT2v-a genes, whereas the recombinant E. coli, pEB1, possessed only that of the VT2 gene. The specific activities of extracellular VT2 determined in HeLa cells ranged from 0.3 to 41.7 TCD50 per microgram of protein in strains carrying the VT2 gene target and from 0 to 50.0 TCD50 per microgram of protein in strains carrying only the VT2 variant target (TCD50 is the tissue culture dose by which 50% of the cells were affected), suggesting that phenotypic expression does not correlate with genotype. Images PMID:1679436
Xu, Q F; Yuan, W; Zhao, X J; Li, B; Wang, H Y
2016-02-01
To investigate the exercise-related risk at anaerobic threshold(AT) in patients with chronic obstructive pulmonary disease(COPD). Sixty two patients [men 56, women 6, aged (66±8) yr] with stable COPD in Beijing Friendship Hospital during 2013-2014, participated in this study. Incremental symptom-limited cardiopulmonary exercise test was performed on cycle ergometer. The AT was determined using the V-Slope technique and ventilatory equivalents for carbon dioxide and oxygen. Symptoms, 10-lead electrocardiogram, oxygen saturation by pulse oximetry(SpO(2)) were monitored during exercise. The AT, detectable in 53 patients, occurred at (68±10)% of peak oxygen uptake(peak VO(2)). The SpO(2) was in the safe range (94±2) % and the respiratory reserve was relatively high at AT (i.e. 48%). High-intensity exercise training can be performed in patients with moderate-to- severe COPD without resting oxygen desaturation.
Electrical switching studies on Si15Te85-xCux bulk (1 ≤ x ≤ 5) glasses
NASA Astrophysics Data System (ADS)
Roy, Diptoshi; Nadig, Chinmayi H. S.; Krishnan, Aravindh; Karanam, Akshath; Abhilash, R.; Jagannatha K., B.; Das, Chandasree
2018-05-01
Bulk ingots of Si15Te85-xCux (1 ≤ x ≤ 5) glasses are concocted by typical melt quenching technique. XRD validate the non-crystalline feature of the prepared quenched sample. The samples are found to display threshold type of electrical switching behavior. The switching behavior on all the samples is noticed without any disturbances. Compositional dependence of threshold voltage of Si15Te85-xCux (1 ≤ x ≤ 5) glasses has been studied and it has been found that VT increases as the atomic percentage of dopant (copper) increases in the host matrix. The distinguished behavior has been envisaged and correlated to the improvement in network connectivity and rigidity with the addition of Cu.
Tan, Xiao-yue; Sun, Xing-guo; Hu, Sheng-shou; Zhang, Jian; Huang, Jie; Chen, Zhi-gao; Ma, Li
2015-07-01
This study aimed to investigate the feature of D(L)CO (Diffusion Lung Capacity for Carbon Monoxide) in CHF (left ventricular heart failure) patients, underlying pathophysiological mechanism and clinical significance. We retrospectively studied the D(L)CO, pulmonary ventilation function, cardiopulmonary exercise testing and related clinical information in severer HF patients. Peak VO2 severely decreased to 34 ± 7 percentage of predicted(%pred) and anaerobic threshold to 48 ± 11%pred in all patients. D(L)CO moderately decreased to 63 ± 12%pred and there were 25 patients lower than 80%pred. FVC, FEV1, FEV1/FVC and TLC were 75 ± 14%pred, 71 ± 17%pred, 97 ± 11%pred, and 79 ± 13%pred, which indicated borderline or mild restrictive ventilatory dysfunction. The decrease of D(L)CO was more severe than those of TLC, FEV1 and FVC. For patients with severe CHF, cardiopulmonary exercise function is extremely limited, D(L)CO generally moderately declines and ventilation function is merely mildly limited. D(L)CO is the parameter for cardiopulmonary coupling, reflecting limitation of the cardiovascular dysfunction while without ventilatory limit.
Dauthier, C; Gaudy, J H; Willer, J C
1980-01-01
The search for a technique making it possible to dissociate the analgesia and ventilatory depression of central analgesics led to a comparison of the effects of naloxone, a specific morphinomimetic antagonist, with almitrine, a ventilatory stimulant with a peripheral action, on muzzle opening reflex and blood gases. Five male dogs (Beagles, aged one year), anaesthetised with Alfetesine were treated separately with the two drugs used alone and after fentanyl analgesia (injection of fractionnated doses up to the threshold of apnoea). The association of the two drugs was also tested in tyhe dog after analgesia. The parameters studied were muzzle opening reflex, as an indication of analgesia, and blood gases, and were observed for 45 minutes, including 15 minutes control. 1 - The intravenous injection of 1,2 mg of naloxone had the effect of increasing the surface area of muscle potentials with a maximum of 7 per cent (p 0.001) at the 15 th minute. By contrast, no significant change in blood gases was seen. In the same dogs given fentanyl analgesia, naloxone not only reversed respiratory depression but had a stimulatory effect on MOR reaching 7 per cent (p 0.001) at the 30 th minute. 2 - The effects of 1 mg.kg-1 of almitrine were characterised by a fall in MOR for a period equal to that of the study and a minimum of 7.8 per cent (p 0.001) at the 20 th minute. At the same time, marked ventilatory stimulation was seen. PO2 rose by 22.7 per cent (p 0.02) at the 5 th minute. PCO2 fell during the 30 minutes studied with a minimum of 39.6 per cent (p 0.01) at the 20 th minute. Almitrine did not antagonise the depression of MOR caused by fentanyl but reversed the respiratory depression of the analgesic, increasing PO2 by 26 per cent (p 0.01) and decreasing PCO2 by 25.7 per cent (p 0.01). 3 - The combination of both drugs cancelled out the abolition of the reflex by fentanyl then facilitated it up to 24.7 per cent (p 0.001) in comparison with the animal not receiving any analgesic. By contrast, the ventilatory action of almitrine was not potentialised by naloxone. In view of these data, and in the absence of any emergency, the choice of naloxone as an antagonist of ventilatory depression of central analgesics should not be preferential in order to avoid the rebound effect.
Cardiopulmonary Responses to Supine Cycling during Short-Arm Centrifugation
NASA Technical Reports Server (NTRS)
Vener, J. M.; Simonson, S. R.; Stocks, J.; Evettes, S.; Bailey, K.; Biagini, H.; Jackson, C. G. R.; Greenleaf, J. E.; Dalton, Bonnie P. (Technical Monitor)
2001-01-01
The purpose of this study was to investigate cardiopulmonary responses to supine cycling with concomitant +G(sub z) acceleration using the NASA/Ames Human Powered Short-Arm Centrifuge (HPC). Subjects were eight consenting males (32+/-5 yrs, 178+/-5 cm, 86.1+/- 6.2 kg). All subjects completed two maximal exercise tests on the HPC (with and without acceleration) within a three-day period. A two tailed t-test with statistical significance set at p less than or equal to 0.05 was used to compare treatments. Peak acceleration was 3.4+/-0.1 G(sub z), (head to foot acceleration). Peak oxygen uptake (VO2(sub peak) was not different between treatment groups (3.1+/-0.1 Lmin(exp -1) vs. 3.2+/-0.1 Lmin(exp -1) for stationary and acceleration trials, respectively). Peak HR and pulmonary minute ventilation (V(sub E(sub BTPS))) were significantly elevated (p less than or equal to 0.05) for the acceleration trial (182+/-3 BPM (Beats per Minute); 132.0+/-9.0 Lmin(exp -1)) when compared to the stationary trial (175+/-3 BPM; 115.5+/-8.5 Lmin(exp -1)). Ventilatory threshold expressed as a percent of VO2(sub peak) was not different for acceleration and stationary trials (72+/-2% vs. 68+/-2% respectively). Results suggest that 3.4 G(sub z) acceleration does not alter VO2(sub peak) response to supine cycling. However, peak HR and V(sub E(sub BTPS)) response may be increased while ventilatory threshold response expressed as a function of percent VO2(sub peak) is relatively unaffected. Thus, traditional exercise prescription based on VO2 response would be appropriate for this mode of exercise. Prescriptions based on HR response may require modification.
Farah, B Q; Ritti-Dias, R M; Balagopal, P B; Hill, J O; Prado, W L
2014-04-01
Aerobic exercise improves cardiovascular health in general, but whether the impact varies with exercise intensity is not clear. The aim of the current study was to compare the effects of a high-intensity aerobic exercise training (HIT) vs. a low-intensity aerobic exercise training (LIT) on blood pressure (BP), heart rate (HR) and heart rate variability (HRV) in obese adolescents. Forty-three (13-18 years) Tanner stage (III-IV) matched obese adolescents were studied in a randomized trial of either HIT (corresponding to the ventilatory threshold I; n = 20) or LIT (corresponding to 20% below the ventilatory threshold I; n = 23) programme for a period of 6 months. All participants also received a multidisciplinary therapy that included nutritional, psychological and clinical counselling. Both HIT and LIT sessions were isocaloric, with energy expenditure set at 350 kcal. BP, HR and HRV were measured along with markers of body adiposity and insulin resistance before and after the respective interventions. The participants in both groups had similar physical and clinical characteristics. After the 6-month intervention, systolic, diastolic and mean BP decreased (P < 0.05, for all) similarly in both groups, whereas waist circumference, HR and HRV showed beneficial changes only in the HIT group (P < 0.05). Aerobic exercise training set at a high intensity compared with the low intensity appears to have additional benefits on abdominal obesity and cardiovascular health in that it enhances the parasympathetic and autonomic modulation of the heart in obese adolescents. © 2013 The Authors. Pediatric Obesity © 2013 International Association for the Study of Obesity.
Tamburus, Nayara Y; Paula, Roberta F L; Kunz, Vandeni C; César, Marcelo C; Moreno, Marlene A; da Silva, Ester
2015-01-01
Autonomic dysfunction and inflammatory activity are involved in the development and progression of coronary artery disease (CAD), and exercise training has been shown to confer a cardiovascular benefit. To evaluate the effects that interval training (IT) based on ventilatory anaerobic threshold (VAT) has on heart rate variability (HRV) and high-sensitivity C-reactive protein (hs-CRP) levels, as well as the relationship between both levels, in patients with CAD and/or cardiovascular risk factors (RF). Forty-two men (aged 57.88±6.20 years) were divided into two training groups, CAD-T (n= 12) and RF-T (n= 10), and two control groups, CAD-C (n= 10) and RF-C (n=10). Heart rate and RR intervals in the supine position, cardiopulmonary exercise tests, and hs-CRP levels were measured before and after IT. HRV was analyzed by spectral and symbolic analysis. The CAD-T and RF-T underwent a 16-week IT program of three weekly sessions at training intensities based on the VAT. In the RF-T, cardiac sympathetic modulation index and hs-CRP decreased (p<0.02), while cardiac parasympathetic modulation index increased (p<0.02). In the CAD-T, cardiac parasympathetic modulation index increased, while hs-CRP, systolic, and diastolic blood pressures decreased (p<0.02). Both control groups showed increase in hs-CRP parameters (p<0.02). There was a strong and significant association between parasympathetic and sympathetic modulations with hs-CRP. The IT program based on the VAT promoted a decrease in hs-CRP associated with improvement in cardiac autonomic modulation.
Alberton, C L; Kanitz, A C; Pinto, S S; Antunes, A H; Finatto, P; Cadore, E L; Kruel, L F M
2013-08-01
The aim of this study was to compare the cardiorespiratory variables corresponding to the anaerobic threshold (AT) between different water-based exercises using two methods of determining the AT, the heart rate deflection point and ventilatory method, and to correlate the variables in both methods. Twenty young women performed three exercise sessions in the water. Maximal tests were performed in the water-based exercises stationary running, frontal kick and cross country skiing. The protocol started at a rate of 80 cycles per minute (cycle.min-1) for 2 min with subsequent increments of 10 cycle.min-1 every minute until exhaustion, with measurements of heart rate, oxygen uptake and ventilation throughout test. After, the two methods were used to determine the values of these variables corresponding to the AT for each of the exercises. Comparisons were made using two-way ANOVA for repeated measures with Bonferroni's post hoc test. To correlate the same variables determined by the two methods, the intra-class correlation coefficient test (ICC) was used. For all the variables, no significant differences were found between the methods of determining the AT and the three exercises. Moreover, the ICC values of each variable determined by the two methods were high and significant. The estimation of the heart rate deflection point can be used as a simple and practical method of determining the AT, which can be used when prescribing these exercises. In addition, these cardiorespiratory parameters may be determined performing the test with only one of the evaluated exercises, since there were no differences in the evaluated variables.
Comparison of anaerobic threshold determined by visual and mathematical methods in healthy women.
Higa, M N; Silva, E; Neves, V F C; Catai, A M; Gallo, L; Silva de Sá, M F
2007-04-01
Several methods are used to estimate anaerobic threshold (AT) during exercise. The aim of the present study was to compare AT obtained by a graphic visual method for the estimate of ventilatory and metabolic variables (gold standard), to a bi-segmental linear regression mathematical model of Hinkley's algorithm applied to heart rate (HR) and carbon dioxide output (VCO2) data. Thirteen young (24 +/- 2.63 years old) and 16 postmenopausal (57 +/- 4.79 years old) healthy and sedentary women were submitted to a continuous ergospirometric incremental test on an electromagnetic braking cycloergometer with 10 to 20 W/min increases until physical exhaustion. The ventilatory variables were recorded breath-to-breath and HR was obtained beat-to-beat over real time. Data were analyzed by the nonparametric Friedman test and Spearman correlation test with the level of significance set at 5%. Power output (W), HR (bpm), oxygen uptake (VO2; mL kg(-1) min(-1)), VO2 (mL/min), VCO2 (mL/min), and minute ventilation (VE; L/min) data observed at the AT level were similar for both methods and groups studied (P > 0.05). The VO2 (mL kg(-1) min(-1)) data showed significant correlation (P < 0.05) between the gold standard method and the mathematical model when applied to HR (rs = 0.75) and VCO2 (rs = 0.78) data for the subjects as a whole (N = 29). The proposed mathematical method for the detection of changes in response patterns of VCO2 and HR was adequate and promising for AT detection in young and middle-aged women, representing a semi-automatic, non-invasive and objective AT measurement.
Exercise Ventilatory Limitation: The Role Of Expiratory Flow Limitation
Babb, Tony G.
2012-01-01
Ventilatory limitation to exercise remains an important unresolved clinical issue; as a result, many individuals misinterpret the effects of expiratory flow limitation as an all-or-nothing phenomenon. Expiratory flow limitation is not all-or-none; approaching maximal expiratory flow can have important effects not only on ventilatory capacity but also on breathing mechanics, ventilatory control, and possibly exertional dyspnea and exercise intolerance. PMID:23038244
Schell, W A; Jones, A M; Garvey, E P; Hoekstra, W J; Schotzinger, R J; Alexander, B D
2017-03-01
The in vitro activities of fungal CYP51 inhibitors VT-1161 and VT-1129 were determined for Candida glabrata ( n = 34) and C. krusei ( n = 50). C. glabrata isolates were screened for FKS gene mutations. All isolates were resistant clinically and/or in vitro to at least one standard antifungal compound. VT-1161 and VT-1129 MICs for all isolates were at least 5-fold below achievable human plasma levels for VT-1161. VT-1161 and VT-1129 are promising for the treatment of resistant C. glabrata and C. krusei infections. Copyright © 2017 American Society for Microbiology.
Quantifying the ventilatory control contribution to sleep apnoea using polysomnography.
Terrill, Philip I; Edwards, Bradley A; Nemati, Shamim; Butler, James P; Owens, Robert L; Eckert, Danny J; White, David P; Malhotra, Atul; Wellman, Andrew; Sands, Scott A
2015-02-01
Elevated loop gain, consequent to hypersensitive ventilatory control, is a primary nonanatomical cause of obstructive sleep apnoea (OSA) but it is not possible to quantify this in the clinic. Here we provide a novel method to estimate loop gain in OSA patients using routine clinical polysomnography alone. We use the concept that spontaneous ventilatory fluctuations due to apnoeas/hypopnoeas (disturbance) result in opposing changes in ventilatory drive (response) as determined by loop gain (response/disturbance). Fitting a simple ventilatory control model (including chemical and arousal contributions to ventilatory drive) to the ventilatory pattern of OSA reveals the underlying loop gain. Following mathematical-model validation, we critically tested our method in patients with OSA by comparison with a standard (continuous positive airway pressure (CPAP) drop method), and by assessing its ability to detect the known reduction in loop gain with oxygen and acetazolamide. Our method quantified loop gain from baseline polysomnography (correlation versus CPAP-estimated loop gain: n=28; r=0.63, p<0.001), detected the known reduction in loop gain with oxygen (n=11; mean±sem change in loop gain (ΔLG) -0.23±0.08, p=0.02) and acetazolamide (n=11; ΔLG -0.20±0.06, p=0.005), and predicted the OSA response to loop gain-lowering therapy. We validated a means to quantify the ventilatory control contribution to OSA pathogenesis using clinical polysomnography, enabling identification of likely responders to therapies targeting ventilatory control. Copyright ©ERS 2015.
Quantifying the ventilatory control contribution to sleep apnoea using polysomnography
Terrill, Philip I.; Edwards, Bradley A.; Nemati, Shamim; Butler, James P.; Owens, Robert L.; Eckert, Danny J.; White, David P.; Malhotra, Atul; Wellman, Andrew; Sands, Scott A.
2015-01-01
Elevated loop gain, consequent to hypersensitive ventilatory control, is a primary nonanatomical cause of obstructive sleep apnoea (OSA) but it is not possible to quantify this in the clinic. Here we provide a novel method to estimate loop gain in OSA patients using routine clinical polysomnography alone. We use the concept that spontaneous ventilatory fluctuations due to apnoeas/hypopnoeas (disturbance) result in opposing changes in ventilatory drive (response) as determined by loop gain (response/disturbance). Fitting a simple ventilatory control model (including chemical and arousal contributions to ventilatory drive) to the ventilatory pattern of OSA reveals the underlying loop gain. Following mathematical-model validation, we critically tested our method in patients with OSA by comparison with a standard (continuous positive airway pressure (CPAP) drop method), and by assessing its ability to detect the known reduction in loop gain with oxygen and acetazolamide. Our method quantified loop gain from baseline polysomnography (correlation versus CPAP-estimated loop gain: n=28; r=0.63, p<0.001), detected the known reduction in loop gain with oxygen (n=11; mean±SEM change in loop gain (ΔLG) −0.23±0.08, p=0.02) and acetazolamide (n=11; ΔLG −0.20±0.06, p=0.005), and predicted the OSA response to loop gain-lowering therapy. We validated a means to quantify the ventilatory control contribution to OSA pathogenesis using clinical polysomnography, enabling identification of likely responders to therapies targeting ventilatory control. PMID:25323235
Smith, Abbie E; Walter, Ashley A; Graef, Jennifer L; Kendall, Kristina L; Moon, Jordan R; Lockwood, Christopher M; Fukuda, David H; Beck, Travis W; Cramer, Joel T; Stout, Jeffrey R
2009-02-11
Intermittent bouts of high-intensity exercise result in diminished stores of energy substrates, followed by an accumulation of metabolites, promoting chronic physiological adaptations. In addition, beta-alanine has been accepted has an effective physiological hydrogen ion (H+) buffer. Concurrent high-intensity interval training (HIIT) and beta-alanine supplementation may result in greater adaptations than HIIT alone. The purpose of the current study was to evaluate the effects of combining beta-alanine supplementation with high-intensity interval training (HIIT) on endurance performance and aerobic metabolism in recreationally active college-aged men. Forty-six men (Age: 22.2 +/- 2.7 yrs; Ht: 178.1 +/- 7.4 cm; Wt: 78.7 +/- 11.9; VO2peak: 3.3 +/- 0.59 l.min-1) were assessed for peak O2 utilization (VO2peak), time to fatigue (VO2TTE), ventilatory threshold (VT), and total work done at 110% of pre-training VO2peak (TWD). In a double-blind fashion, all subjects were randomly assigned into one either a placebo (PL - 16.5 g dextrose powder per packet; n = 18) or beta-alanine (BA - 1.5 g beta-alanine plus 15 g dextrose powder per packet; n = 18) group. All subjects supplemented four times per day (total of 6 g/day) for the first 21-days, followed by two times per day (3 g/day) for the subsequent 21 days, and engaged in a total of six weeks of HIIT training consisting of 5-6 bouts of a 2:1 minute cycling work to rest ratio. Significant improvements in VO2peak, VO2TTE, and TWD after three weeks of training were displayed (p < 0.05). Increases in VO2peak, VO2TTE, TWD and lean body mass were only significant for the BA group after the second three weeks of training. The use of HIIT to induce significant aerobic improvements is effective and efficient. Chronic BA supplementation may further enhance HIIT, improving endurance performance and lean body mass.
CT volumetry can potentially predict the local stage for gastric cancer after chemotherapy
Wang, Zhi-Cong; Wang, Chen; Ding, Ying; Ji, Yuan; Zeng, Meng-Su; Rao, Sheng-Xiang
2017-01-01
PURPOSE We aimed to evaluate the value of CT tumor volumetry for predicting T and N stages of gastric cancer after chemotherapy, with pathologic results as the reference standard. METHODS This study retrospectively evaluated 42 patients diagnosed with gastric cancer, who underwent chemotherapy followed by surgery. Pre- and post-treatment CT tumor volumes (VT) were measured in portal venous phase and volume reduction ratios were calculated. Correlations between pre- and post-treatment VT, reduction ratio, and pathologic stages were analyzed. Receiver operator characteristic (ROC) analyses were also performed to assess diagnostic performance for prediction of downstaging to T0–2 stage and N0 stage. RESULTS Pretreatment VT, post-treatment VT, and VT reduction ratio were significantly correlated with T stage (rs=0.329, rs=0.546, rs= −0.422, respectively). Post-treatment VT and VT reduction ratio were significantly correlated with N stage (rs=0.442 and rs= −0.376, respectively). Pretreatment VT, post-treatment VT, and VT reduction ratio were significantly different between T0–2 and T3,4 stage tumors (P = 0.05, P < 0.001, and P = 0.002, respectively). The differences between N0 and ≥N1 groups were also statistically significant (P = 0.005 for post-treatment VT, P = 0.016 for VT reduction ratio, respectively). The area under the ROC curve (AUC) for identification of T0–2 groups was 0.70 for pretreatment VT, 0.88 for post-treatment VT, and 0.82 for VT reduction ratio, respectively. AUC was 0.78 for post-treatment VT and 0.74 for VT reduction ratio for identification of N0 groups. CONCLUSION CT tumor volumetry, particularly post-treatment measurement of VT, is potentially valuable for predicting histopathologic T and N stages after chemotherapy in patients with gastric cancer. PMID:28703101
Spectroscopic analysis of electron trapping levels in pentacene field-effect transistors
NASA Astrophysics Data System (ADS)
Park, Chang Bum
2014-08-01
Electron trapping phenomena have been investigated with respect to the energy levels of localized trap states and bias-induced device instability effects in pentacene field-effect transistors. The mechanism of the photoinduced threshold voltage shift (ΔVT) is presented by providing a ΔVT model governed by the electron trapping. The trap-and-release behaviour functionalized by photo-irradiation also shows that the trap state for electrons is associated with the energy levels in different positions in the forbidden gap of pentacene. Spectroscopic analysis identifies two kinds of electron trap states distributed above and below the energy of 2.5 eV in the band gap of the pentacene crystal. The study of photocurrent spectra shows the specific trap levels of electrons in energy space that play a substantial role in causing device instability. The shallow and deep trapping states are distributed at two centroidal energy levels of ˜1.8 and ˜2.67 eV in the pentacene band gap. Moreover, we present a systematic energy profile of electron trap states in the pentacene crystal for the first time.
Ciammola, Andrea; Sassone, Jenny; Sciacco, Monica; Mencacci, Niccolò E; Ripolone, Michela; Bizzi, Caterina; Colciago, Clarissa; Moggio, Maurizio; Parati, Gianfranco; Silani, Vincenzo; Malfatto, Gabriella
2011-01-01
Mitochondrial defects that affect cellular energy metabolism have long been implicated in the etiology of Huntington's disease (HD). Indeed, several studies have found defects in the mitochondrial functions of the central nervous system and peripheral tissues of HD patients. In this study, we investigated the in vivo oxidative metabolism of exercising muscle in HD patients. Ventilatory and cardiometabolic parameters and plasma lactate concentrations were monitored during incremental cardiopulmonary exercise in twenty-five HD subjects and twenty-five healthy subjects. The total exercise capacity was normal in HD subjects but notably the HD patients and presymptomatic mutation carriers had a lower anaerobic threshold than the control subjects. The low anaerobic threshold of HD patients was associated with an increase in the concentration of plasma lactate. We also analyzed in vitro muscular cell cultures and found that HD cells produce more lactate than the cells of healthy subjects. Finally, we analyzed skeletal muscle samples by electron microscopy and we observed striking mitochondrial structural abnormalities in two out of seven HD subjects. Our findings confirm mitochondrial abnormalities in HD patients' skeletal muscle and suggest that the mitochondrial dysfunction is reflected functionally in a low anaerobic threshold and an increased lactate synthesis during intense physical exercise. Copyright © 2010 Movement Disorder Society.
NASA Astrophysics Data System (ADS)
Hayama, K.; Ohyama, H.; Simoen, E.; Rafí, J. M.; Mercha, A.; Claeys, C.
2004-04-01
The degradation of the electrical properties of deep submicron metal-oxide-semiconductor field-effect transistors (MOSFETs) by 2 MeV electron irradiation at high temperatures was studied. The irradiation temperatures were 30, 100, 150 and 200 °C, and the fluence was fixed at 1015e/cm2. For most experimental conditions, the threshold voltage (VT) is observed to reduce in absolute value both for n- and p-MOSFETs. This reduction is most pronounced at 100 °C, as at this irradiation temperature, the radiation-induced density of interface traps is highest. It is proposed that hydrogen neutralization of the dopants in the substrate plays a key role, whereby the hydrogen is released from the gate by the 2 MeV electrons.
The effect of ethnicity on the vascular responses to cold exposure of the extremities.
Maley, Matthew J; Eglin, Clare M; House, James R; Tipton, Michael J
2014-11-01
Cold injuries are more prevalent in individuals of African descent (AFD). Therefore, we investigated the effect of extremity cooling on skin blood flow (SkBF) and temperature (T sk) between ethnic groups. Thirty males [10 Caucasian (CAU), 10 Asian (ASN), 10 AFD] undertook three tests in 30 °C air whilst digit T sk and SkBF were measured: (i) vasomotor threshold (VT) test--arm immersed in 35 °C water progressively cooled to 10 °C and rewarmed to 35 °C to identify vasoconstriction and vasodilatation; (ii) cold-induced vasodilatation (CIVD) test--hand immersed in 8 °C water for 30 min followed by spontaneous warming; (iii) cold sensitivity (CS) test--foot immersed in 15 °C water for 2 min followed by spontaneous warming. Cold sensory thresholds of the forearm and finger were also assessed. In the VT test, vasoconstriction and vasodilatation occurred at a warmer finger T sk in AFD during cooling [21.2 (4.4) vs. 17.0 (3.1) °C, P = 0.034] and warming [22.0 (7.9) vs. 12.1 (4.1) °C, P = 0.002] compared with CAU. In the CIVD test, average SkBF during immersion was greater in CAU [42 (24) %] than ASN [25 (8) %, P = 0.036] and AFD [24 (13) %, P = 0.023]. Following immersion, SkBF was higher and rewarming faster in CAU [3.2 (0.4) °C min(-1)] compared with AFD [2.5 (0.7) °C min(-1), P = 0.037], but neither group differed from ASN [3.0 (0.6) °C min(-1)]. Responses to the CS test and cold sensory thresholds were similar between groups. AFD experienced a more intense protracted finger vasoconstriction than CAU during hand immersion, whilst ASN experienced an intermediate response. This greater sensitivity to cold may explain why AFD are more susceptible to cold injuries.
Variable Inhibition by Falling CO2 of Hypoxic Ventilatory Response in Man,
1983-06-21
alkalosis which, in turn, inhibits the ventilatory response to hypoxia (4,5,11). Thus for the usual measurement of the acute ventilatory response to...rest for 20 minutes. All of the ventilatory response tests were performed with the subject breathing through a respiratory valve (Model 2700, Hans...increase ventilation because the inhibition by hypocapnic alkalosis is prevented by adding CO2 to the inspired air to maintain C02 and pH at their
NASA Astrophysics Data System (ADS)
Kitayama, Shigehisa; Soh, Zu; Hirano, Akira; Tsuji, Toshio; Takiguchi, Noboru; Ohtake, Hisao
Ventilatory signal is a kind of bioelectric signals reflecting the ventilatory conditions of fish, and has received recent attention as an indicator for assessment of water quality, since breathing is adjusted by the respiratory center according to changes in the underwater environment surrounding the fish. The signals are thus beginning to be used in bioassay systems for water examination. Other than ventilatory conditions, swimming behavior also contains important information for water examination. The conventional bioassay systems, however, only measure either ventilatory signals or swimming behavior. This paper proposes a new unconstrained and noninvasive measurement method that is capable of conducting ventilatory signal measurement and behavioral analysis of fish at the same time. The proposed method estimates the position and the velocity of a fish in free-swimming conditions using power spectrum distribution of measured ventilatory signals from multiple electrodes. This allowed the system to avoid using a camera system which requires light sources. In order to validate estimation accuracy, the position and the velocity estimated by the proposed method were compared to those obtained from video analysis. The results confirmed that the estimated error of the fish positions was within the size of fish, and the correlation coefficient between the velocities was 0.906. The proposed method thus not only can measure the ventilatory signals, but also performs behavioral analysis as accurate as using a video camera.
Graphics Software For VT Terminals
NASA Technical Reports Server (NTRS)
Wang, Caroline
1991-01-01
VTGRAPH graphics software tool for DEC/VT computer terminal or terminals compatible with it, widely used by government and industry. Callable in FORTRAN or C language, library program enabling user to cope with many computer environments in which VT terminals used for window management and graphic systems. Provides PLOT10-like package plus color or shade capability for VT240, VT241, and VT300 terminals. User can easily design more-friendly user-interface programs and design PLOT10 programs on VT terminals with different computer systems. Requires ReGis graphics set terminal and FORTRAN compiler.
Jin, Qi; Jacobsen, Peter Karl; Pehrson, Steen; Chen, Xu
2017-11-01
Ventricular tachycardia (VT) recurrence after catheter ablation for electrical storm is commonly seen in patients with ischemic cardiomyopathy (ICM). We hypothesized that VT recurrence can be predicted and be related to the all-cause death after VT storm ablation guided by remote magnetic navigation (RMN) in patients with ICM. A total of 54 ICM patients (87% male; mean age, 65 ± 7.1 years) presenting with VT storm undergoing acute ablation using RMN were enrolled. Acute complete ablation success was defined as noninducibility of any sustained monomorphic VT at the end of the procedure. Early VT recurrence was defined as the occurrence of sustained VT within 1 month after the first ablation. After a mean follow-up of 17.1 months, 27 patients (50%) had freedom from VT recurrence. Sustained VT recurred in 12 patients (22%) within 1 month following the first ablation. In univariate analysis, VT recurrence was associated with incomplete procedural success (hazard ratio [HR]: 6.25, 95% confidence interval [CI]: 1.20-32.47, P = 0.029), lack of amiodarone usage before ablation (HR: 4.71, 95% CI: 1.12-19.7, P = 0.034), and a longer procedural time (HR: 1.023, 95% CI: 1.00-1.05, P = 0.05). The mortality of patients with early VT recurrence was higher than that of patients without recurrence (P < 0.01). Inducibility of any VT at the end of procedure for VT storm guided by RMN is the strongest predictor of VT recurrence. ICM patients who have early recurrences after VT storm ablation are at high risk of all-cause death. © 2017 Wiley Periodicals, Inc.
Low Voltage Electrowetting-on-Dielectric Platform using Multi-Layer Insulators
Lin, Yan-You; Evans, Randall D.; Welch, Erin; Hsu, Bang-Ning; Madison, Andrew C.; Fair, Richard B.
2010-01-01
A low voltage, two-level-metal, and multi-layer insulator electrowetting-on-dielectric (EWD) platform is presented. Dispensing 300pl droplets from 140nl closed on-chip reservoirs was accomplished with as little as 11.4V solely through EWD forces, and the actuation threshold voltage was 7.2V with a 1Hz voltage switching rate between electrodes. EWD devices were fabricated with a multilayer insulator consisting of 135nm sputtered tantalum pentoxide (Ta2O5) and 180nm parylene C coated with 70nm of CYTOP. Furthermore, the minimum actuation threshold voltage followed a previously published scaling model for the threshold voltage, VT, which is proportional to (t/εr)1/2, where t and εr are the insulator thickness and dielectric constant respectively. Device threshold voltages are compared for several insulator thicknesses (200nm, 500nm, and 1µm), different dielectric materials (parylene C and tantalum pentoxide), and homogeneous versus heterogeneous compositions. Additionally, we used a two-level-metal fabrication process, which enables the fabrication of smaller and denser electrodes with high interconnect routing flexibility. We also have achieved low dispensing and actuation voltages for scaled devices with 30pl droplets. PMID:20953362
Hong, Caron M; Xu, Da-Zhong; Lu, Qi; Cheng, Yunhui; Pisarenko, Vadim; Doucet, Danielle; Brown, Margaret; Aisner, Seena; Zhang, Chunxiang; Deitch, Edwin A; Delphin, Ellise
2010-06-01
Protective mechanical ventilation with low tidal volume (Vt) and low plateau pressure reduces mortality and decreases the length of mechanical ventilation in patients with acute respiratory distress syndrome. Mechanical ventilation that will protect normal lungs during major surgical procedures of long duration may improve postoperative outcomes. We performed an animal study comparing 3 ventilation strategies used in the operating room in normal lungs. We compared the effects on pulmonary mechanics, inflammatory mediators, and lung tissue injury. Female pigs were randomized into 3 groups. Group H-Vt/3 (n = 6) was ventilated with a Vt of 15 mL/kg predicted body weight (PBW)/positive end-expiratory pressure (PEEP) of 3 cm H(2)O, group L-Vt/3 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 3 cm H(2)O, and group L-Vt/10 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 10 cm H(2)O, for 8 hours. Hemodynamics, airway mechanics, arterial blood gases, and inflammatory markers were monitored. Bronchoalveolar lavage (BAL) was analyzed for inflammatory markers and protein concentration. The right lower lobe was assayed for mRNA of specific cytokines. The right lower lobe and right upper lobe were evaluated histologically. In contrast to groups H-Vt/3 and L-Vt/3, group L-Vt/10 exhibited a 6-fold increase in inflammatory mediators in BAL (P < 0.001). Cytokines in BAL were similar in groups H-Vt/3 and L-Vt/3. Group H-Vt/3 had a significantly lower lung injury score than groups L-Vt/3 and L-Vt/10. Comparing intraoperative strategies, ventilation with high PEEP resulted in increased production of inflammatory markers. Low PEEP resulted in lower levels of inflammatory markers. High Vt/low PEEP resulted in less histologic lung injury.
Histopathology of tympanic membranes from patients with ventilation tubes.
Oktay, Mehmet Faruk; Tansuker, Hasan Deniz; Fukushima, Hisaki; Paparella, Michael M; Schachern, Patricia A; Cureoglu, Sebahattin
2018-06-01
To evaluate the histopathologic changes in tympanic membranes (TMs) with ventilation tubes (VTs). In this retrospective human temporal bone study our overall study group included 4 subgroups of TMs from deceased donors as follows: 24 with a history of VT insertion for chronic otitis media with effusion (COME-VT); 5 with a history of VT insertion for Meniere's disease (MD-VT); 33 without a history of VT insertion for chronic otitis media with effusion (COME); and 14 without a history of VT insertion for Meniere's disease (MD). We classified the extent of migration of the outer keratinized squamous epithelium onto the inner surface of TM perforations and noted the presence and location of tympanosclerosis, of atrophy, of perforation, and/or of cholesteatoma formation. Tympanosclerosis occurred in 14/24 TMs in the COME-VT subgroup; 2/5, MD-VT; 7/33, COME; and 0/14, MD. The VT insertion site was mostly in the anteroinferior (63%) quadrant of the TM; tympanosclerosis occurred more frequently in the posteroinferior (42%) and posterosuperior (33%) quadrants. We found no significant correlation between the location of tympanosclerosis and the VT insertion site (P>0.05). Atrophy occurred in 7/24 TMs in the COME-VT subgroup; 3/5, MD-VT; 8/33, COME; and 2/14, MD. We found no significant correlation between the location of atrophy and the VT insertion site; however, atrophy was located mostly in the anteroinferior quadrant (one of the most common VT insertion sites) of the TM. Regarding the ingrowth of keratinized epithelium, the mucocutanous junction was detected at any point at the inner surface of the TM in 50% of the specimens. We observed intratympanic cholesteatoma formation in 2/24 TMs in the COME-VT subgroup. TM changes due to VT insertion are more common than previously realized. Meticulous otomicroscopic evaluation of the TM is necessary during tympanomastoidectomies in order to prevent the intratympanic inclusion pearls and squamous epithelial ingrowth to prevent any further cholesteatoma formation. Copyright © 2017. Published by Elsevier B.V.
Impaired ventilatory acclimatization to hypoxia in mice lacking the immediate early gene fos B.
Malik, Mohammad T; Peng, Ying-Jie; Kline, David D; Adhikary, Gautam; Prabhakar, Nanduri R
2005-01-15
Earlier studies on cell culture models suggested that immediate early genes (IEGs) play an important role in cellular adaptations to hypoxia. Whether IEGs are also necessary for hypoxic adaptations in intact animals is not known. In the present study we examined the potential importance of fos B, an IEG in ventilatory acclimatization to hypoxia. Experiments were performed on wild type and mutant mice lacking the fos B gene. Ventilation was monitored by whole body plethysmography in awake animals. Baseline ventilation under normoxia, and ventilatory response to acute hypoxia and hypercapnia were comparable between wild type and mutant mice. Hypobaric hypoxia (0.4 atm; 3 days) resulted in a significant elevation of baseline ventilation in wild type but not in mutant mice. Wild type mice exposed to hypobaric hypoxia manifested an enhanced hypoxic ventilatory response compared to pre-hypobaric hypoxia. In contrast, hypobaric hypoxia had no effect on the hypoxic ventilatory response in mutant mice. Hypercapnic ventilatory responses, however, were unaffected by hypobaric hypoxia in both groups of mice. These results suggest that the fos B, an immediate early gene, plays an important role in ventilatory acclimatization to hypoxia in mice.
This project, sponsored by EPA's Environmental Monitoring for Public Access and Community Tracking (EMPACT) program, evaluated the ability of an automated biological monitoring system that measures fish ventilatory responses (ventilatory rate, ventilatory depth, and cough rate) t...
Serrano-Pinto, Vania; Vazquez-Boucard, Celia; Villarreal-Colmenares, Humberto
2003-01-01
Vitellins from ovaries and eggs at different stages of development in freshwater crayfish (Cherax quadricarinatus) were examined by chromatography, PAGE and SDS-PAGE. With these methods, two forms of vitellin (Vt1 and Vt2) were observed in ovaries and eggs (stages I and V). In ovaries in secondary vitellogenesis, native molecular mass was 470 (Vt1) and 440 (Vt2) kDa. The electrophoretic pattern of the eggs proved to be more complex. The protein molecular mass depend on the development stage of the egg: stage I, 650 kDa (Vt1) and 440 kDa (Vt2); stage V, 390 kDa (Vt1) and 340 kDa (Vt2). The identified vitellins appear to be lipo-glycocarotenoprotein. A similar vitellin polypeptide composition was observed in the two forms of vitellin from ovaries and eggs in stage V. In ovaries the SDS-PAGE analysis showed four subunits with molecular weights of approximately 180, 120, 95 and 80 kDa (Vt1 and Vt2). The polypeptide composition in the two forms of vitellins in stage I and stage III eggs were different at 195, 190, 130 and 110 kDa (Vt1) and 116 and 107 kDa (Vt2). On the other hand, in stage V eggs, 110, 95, 87 and 75 kDa (Vt1 and Vt2) were identified. Two antibodies (Ab1 and Ab2) were prepared against the purified proteins of stage V eggs and their specificity was demonstrated by radial immunoprecipitation, and Western blotting analysis. Two forms of vitellins were also found in stage V eggs after chromatography on Sepharose CL-2B column and hydroxylapatite and polyacrylamide gel electrophoresis.
Break, Timothy J; Desai, Jigar V; Ferre, Elise M N; Henderson, Christina; Zelazny, Adrian M; Siebenlist, Ulrich; Hoekstra, William J; Schotzinger, Robert J; Garvey, Edward P; Lionakis, Michail S
2018-01-01
Abstract Background Candida albicans, the most common human fungal pathogen, causes chronic mucosal infections in patients with inborn errors of IL-17 immunity that rely heavily on chronic, often lifelong, azole antifungal agents for treatment. However, a rise in azole resistance has predicated a need for developing new antifungal drugs. Objectives To test the in vitro and in vivo efficacy of VT-1161 and VT-1129 in the treatment of oropharyngeal candidiasis with azole-susceptible or -resistant C. albicans strains. Methods MICs of VT-1161, VT-1129 and nine licensed antifungal drugs were determined for 31 Candida clinical isolates. The drug concentrations in mouse serum and tongues were measured following oral administration. IL-17-signalling-deficient Act1−/− mice were infected with fluconazole-susceptible or fluconazole-resistant C. albicans strains, and the amount of mucosal fungal burden was determined after fluconazole or VT-1161 treatment. Results Fourteen isolates (45%) were not fluconazole susceptible (MIC ≥4 mg/L). VT-1161 and VT-1129 showed significant in vitro activity against the majority of the 31 mucosal clinical isolates (MIC50 0.03 and 0.06 mg/L, respectively), including Candida glabrata (MIC50, 0.125 and 0.25 mg/L, respectively). After oral doses, VT-1161 and VT-1129 concentrations in mouse serum and tongues were well above their MIC50 values. VT-1161 was highly effective as treatment of both fluconazole-susceptible and -resistant oropharyngeal candidiasis in Act1−/− mice. Conclusions VT-1129 and VT-1161 exhibit significant in vitro activity against Candida strains, including fluconazole-resistant C. albicans and C. glabrata. VT-1161 administration in mice results in significant mucosal drug accumulation and eradicates infection caused by fluconazole-susceptible and -resistant Candida strains. PMID:29040636
Rao, Rohit P; Danduran, Michael J; Loomba, Rohit S; Dixon, Jennifer E; Hoffman, George M
2012-06-01
Cardiopulmonary exercise testing (CPET) provides assessment of the integrative responses involving the pulmonary, cardiovascular, and skeletal muscle systems. Application of exercise testing remains limited to children who are able to understand and cooperate with the exercise protocol. Near-infrared spectroscopy (NIRS) provides a noninvasive, continuous method to monitor regional tissue oxygenation (rSO2). Our specific aim was to predict anaerobic threshold (AT) during CPET noninvasively using two-site NIRS monitoring. Achievement of a practical noninvasive technology for estimating AT will increase the compatibility of CPET. Patients without structural or acquired heart disease were eligible for inclusion if they were ordered to undergo CPET by a cardiologist. Data from 51 subjects was analyzed. The ventilatory anaerobic threshold (VAT) was computed on [Formula: see text] and respiratory quotient post hoc using the standard V-slope method. The inflection points of the regional rSO2 time-series were identified as the noninvasive regional NIRS AT for each of the two monitored regions (cerebral and kidney). AT calculation made using an average of kidney and brain NIRS matched the calculation made by VAT for the same patient. Two-site NIRS monitoring of visceral organs is a predictor of AT.
Mechanism-specific effects of adenosine on ventricular tachycardia.
Lerman, Bruce B; Ip, James E; Shah, Bindi K; Thomas, George; Liu, Christopher F; Ciaccio, Edward J; Wit, Andrew L; Cheung, Jim W; Markowitz, Steven M
2014-12-01
There is no universally accepted method by which to diagnose clinical ventricular tachycardia (VT) due to cAMP-mediated triggered activity. Based on cellular and clinical data, adenosine termination of VT is thought to be consistent with a diagnosis of triggered activity. However, a major gap in evidence mitigates the validity of this proposal, namely, defining the specificity of adenosine response in well-delineated reentrant VT circuits. To this end, we systematically studied the effects of adenosine in a model of canine reentrant VT and in human reentrant VT, confirmed by 3-dimensional, pace- and substrate mapping. Adenosine (12 mg [IQR 12-24]) failed to terminate VT in 31 of 31 patients with reentrant VT due to structural heart disease, and had no effect on VT cycle length (age, 67 years [IQR 53-74]); ejection fraction, 35% [IQR 20-55]). In contrast, adenosine terminated VT in 45 of 50 (90%) patients with sustained focal right or left outflow tract tachycardia. The sensitivity of adenosine for identifying VT due to triggered activity was 90% (95% CI, 0.78-0.97) and its specificity was 100% (95% CI, 0.89-1.0). Additionally, reentrant circuits were mapped in the epicardial border zone of 4-day-old infarcts in mongrel dogs. Adenosine (300-400 μg/kg) did not terminate sustained VT or have any effect on VT cycle length. These data support the concept that adenosine's effects on ventricular myocardium are mechanism specific, such that termination of VT in response to adenosine is diagnostic of cAMP-mediated triggered activity. © 2014 Wiley Periodicals, Inc.
Ultra-Low-Energy Sub-Threshold Circuits: Program Overview
2007-04-10
with global > 0.1 corner, but so does VUL, VIH 0 .0 5 -_ "or ni n a Global Variatlion 0.0a 0•,lN& 0.24.. 7 Mir" Output Swing Metrics " Need a... VIH . lines plot the VTCs when random local VT mismatch is ap- In Figure 1(b), a NAND gate has sufficient output swing plied to the inverter. One case...the VTC is input-dependent, all inputs are varied simultaneously to >P 1 0 SNM side of largest obtain the worst case ViH and VIL. > 0 ins0nbedsquare
20 CFR 410.430 - Ventilatory studies.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Ventilatory studies. 410.430 Section 410.430... studies. Spirometric tests to measure ventilatory function must be expressed in liters or liters per... least 20 millimeters (mm.) per second. The height of the individual must be recorded. Studies should not...
20 CFR 410.430 - Ventilatory studies.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Ventilatory studies. 410.430 Section 410.430... studies. Spirometric tests to measure ventilatory function must be expressed in liters or liters per... least 20 millimeters (mm.) per second. The height of the individual must be recorded. Studies should not...
OBESITY: CHALLENGES TO VENTILATORY CONTROL DURING EXERCISE A BRIEF REVIEW
Babb, Tony G.
2013-01-01
Obesity is a national health issue in the US. Among the many physiological changes induced by obesity, it also presents a unique challenge to ventilatory control during exercise due to increased metabolic demand of moving larger limbs, increased work of breathing due to extra weight on the chest wall, and changes in breathing mechanics. These challenges to ventilatory control in obesity can be inconspicuous or overt among obese adults but for the most part adaptation of ventilatory control during exercise in obesity appears remarkably unnoticed in the majority of obese people. In this brief review, the changes to ventilatory control required for maintaining normal ventilation during exercise will be examined, especially the interaction between respiratory neural drive and ventilation. Also, gaps in our current knowledge will be discussed. PMID:23707540
Deacon, S P; Paddle, G M
1998-05-01
A health surveillance study of male grain food manufacturing workers used a respiratory health questionnaire and spirometry to assess the prevalence of work-related respiratory symptoms and impaired ventilatory performance. The prevalence of cough, breathlessness, wheeze and chest tightness was between 8-13% but was 20% for rhinitis. Rhinitis was the most common symptom with 37% of those reporting rhinitis describing this as work-related. A case-control analysis of workers reporting rhinitis did not identify any specific occupational activities associated with increased risk of rhinitis. Smoking habit and all respiratory symptoms apart from rhinitis had a significant effect upon ventilatory performance. Occupational exposure to raw grains, flour, ingredients and finished food was categorized as high, medium or low in either continuous or intermediate patterns. Multiple regression analysis confirmed the effects of height, age and smoking upon ventilatory performance. However, occupational exposure to grain, flour, food ingredients and cooked food dusts had no effect upon ventilatory performance. It is concluded that smoking habit is the major determinant of respiratory symptoms and impaired ventilatory function. The excess complaints of rhinitis warrant further study but it would appear that the current occupational exposure limits for grain, flour, food ingredients and cooked food dusts are adequate to protect workers against impairment of ventilatory performance.
Normalization of respiratory sinus arrhythmia by factoring in tidal volume.
Kobayashi, H
1998-09-01
The amplitude of respiratory sinus arrhythmia (RSA) was measured in eight healthy young male students with special reference to the effect of tidal volume (Vt). Under simultaneously controlled respiratory frequency and Vt, the heart rate variability (HRV) of the subjects was measured. While the respiratory frequency was adjusted to either 0.25 or 0.10 Hz, the Vt was controlled at 13 different volumes for each frequency. Linear relationships between RSA amplitude and Vt were observed and close correlations were obtained for 0.25 Hz compared with 0.10 Hz. However, regression equations showed a marked variation among subjects. Furthermore, RSA amplitude was related to vital capacity. Subjects who had lower vital capacity tended to show higher RSA amplitudes at the same Vt. Therefore, the ratio (% Vt) of Vt to vital capacity is a more effective index in normalizing RSA than raw tidal volume. From these results, we have proposed a normalized RSA (RSA amplitude/% Vt) as a new index of autonomic activity that provides a constant value regardless of Vt.
Electromyographic and neuromuscular fatigue thresholds as concepts of fatigue.
Mäestu, Jarek; Cicchella, Antonio; Purge, Priit; Ruosi, Sergio; Jürimäe, Jaak; Jürimäe, Toivo
2006-11-01
The aim of this study was to investigate the concepts of electromyographic (EMG) threshold (EMGT) by integrated EMG (iEMG) signals and neuromuscular fatigue threshold (NMFT) concepts in trained male athletes. Nine competitive national-level male rowers (21.8 +/- 4.4 years; 186.2 +/- 4.6 cm; 79.6 +/- 8.4 kg) took part in this investigation. Subjects were asked to participate in the graded exercise test to volitional exhaustion and 500-, 1,000-, and 2,000-m all-out rowing ergometer tests on a rowing ergometer. During all tests, oxygen consumption parameters, average power, and iEMG of the musculus vastus lateralis were recorded. The second ventilatory threshold (248.9 +/- 26.67 W) and EMGT (258.89 +/- 27.13 W) were not significantly different but were significantly lower than the NMFT (302.25 +/- 45.10 W). During 1,000- and 2,000-m all-out distances, VO(2) increased during the first minute and then leveled on a plateau with a slight decrease at the end of the exercise. Vastus lateralis activity showed a slight increase during all distances that was accompanied by a remarkable increase towards the end of the distance. All measured threshold values were significantly correlated (r > 0.70; p < 0.05) to the rowing ergometer performance characteristics. It was concluded that EMGT is closely related to the aerobic-anaerobic transition phase, because NMFT represents the local fatigue accumulation in the muscle. NMFT indicates the performance capacity of the muscles; therefore, it helps coaches to better predict top athletes' performance.
Ventilatory responses to hypercapnia and hypoxia after 6 h passive hyperventilation in humans
Ren, Xiaohui; Robbins, Peter A
1999-01-01
Acute exposure to hypoxia stimulates ventilation and induces hypocapnia. Long-term exposure to hypoxia generates changes in respiratory control known as ventilatory acclimatization to hypoxia. The object of this study was to investigate the degree to which the hyperventilation and hypocapnia can induce the changes known as ventilatory acclimatization to hypoxia, in the absence of the primary hypoxic stimulus itself.Three 6 h protocols were each performed on twelve healthy volunteers: (1) passive hypocapnic hyperventilation, with end-tidal CO2 pressure (PET,CO2) held 10 Torr below the eupnoeic value; (2) passive eucapnic hyperventilation, with PET,CO2 maintained eucapnic; (3) control.Ventilatory responses to acute hypercapnia and hypoxia were assessed before and half an hour after each protocol.The presence of prior hypocapnia, but not prior hyperventilation, caused a reduction in air-breathing PET,CO2 (P < 0·05, ANOVA), and a leftwards shift of the ventilatory response to hypercapnia (P < 0·05). The presence of prior hyperventilation, but not prior hypocapnia, caused an increase in the ventilatory sensitivity to CO2 (P < 0·05). No significant effects of any protocol were detected on the ventilatory sensitivity to hypoxia.We conclude that following 6 h of passive hyperventilation: (i) the left shift of the VE-PET,CO2 relationship is due to alkalosis and not to hyperventilation; (ii) the increase in slope of the VE-PET,CO2 relationship is due to the hyperventilation and not the alkalosis; and (iii) ventilatory sensitivity to hypoxia is unaltered. PMID:9882758
Arrhythmogenic Mechanisms in a Mouse Model of Catecholaminergic Polymorphic Ventricular Tachycardia
Cerrone, Marina; Noujaim, Sami F.; Tolkacheva, Elena G.; Talkachou, Arkadzi; O’Connell, Ryan; Berenfeld, Omer; Anumonwo, Justus; Pandit, Sandeep V.; Vikstrom, Karen; Napolitano, Carlo; Priori, Silvia G.; Jalife, José
2008-01-01
Catecholaminergic polymorphic ventricular tachycardia (VT) is a lethal familial disease characterized by bidirectional VT, polymorphic VT, and ventricular fibrillation. Catecholaminergic polymorphic VT is caused by enhanced Ca2+ release through defective ryanodine receptor (RyR2) channels. We used epicardial and endocardial optical mapping, chemical subendocardial ablation with Lugol’s solution, and patch clamping in a knockin (RyR2/RyR2R4496C) mouse model to investigate the arrhythmogenic mechanisms in catecholaminergic polymorphic VT. In isolated hearts, spontaneous ventricular arrhythmias occurred in 54% of 13 RyR2/RyR2R4496C and in 9% of 11 wild-type (P=0.03) littermates perfused with Ca2+ and isoproterenol; 66% of 12 RyR2/RyR2R4496C and 20% of 10 wild-type hearts perfused with caffeine and epinephrine showed arrhythmias (P=0.04). Epicardial mapping showed that monomorphic VT, bidirectional VT, and polymorphic VT manifested as concentric epicardial breakthrough patterns, suggesting a focal origin in the His–Purkinje networks of either or both ventricles. Monomorphic VT was clearly unifocal, whereas bidirectional VT was bifocal. Polymorphic VT was initially multifocal but eventually became reentrant and degenerated into ventricular fibrillation. Endocardial mapping confirmed the Purkinje fiber origin of the focal arrhythmias. Chemical ablation of the right ventricular endocardial cavity with Lugol’s solution induced complete right bundle branch block and converted the bidirectional VT into monomorphic VT in 4 anesthetized RyR2/RyR2R4496C mice. Under current clamp, single Purkinje cells from RyR2/RyR2R4496C mouse hearts generated delayed afterdepolarization–induced triggered activity at lower frequencies and level of adrenergic stimulation than wild-type. Overall, the data demonstrate that the His–Purkinje system is an important source of focal arrhythmias in catecholaminergic polymorphic VT. PMID:17872467
Stein-Merlob, Ashley F.; Kessinger, Chase W.; Erdem, S. Sibel; Zelada, Henry; Hilderbrand, Scott A.; Lin, Charles P.; Tearney, Guillermo J.; Jaff, Michael R.; Reed, Guy L.; Henke, Peter K.; McCarthy, Jason R.; Jaffer, Farouc A.
2015-01-01
Fibrinolytic therapy of venous thromboembolism (VTE) is increasingly utilized, yet limited knowledge is available regarding in vivo mechanisms that govern fibrinolytic efficacy. In particular, it is unknown how age-dependent thrombus organization limits direct blood contact with fibrin, the target of blood-based fibrinolytic agents. Utilizing high-resolution in vivo optical molecular imaging with FTP11, a near-infrared fluorescence (NIRF) fibrin-specific reporter, here we investigated the in vivo interrelationships of blood accessibility to fibrin, thrombus age, thrombus neoendothelialization, and fibrinolysis in murine venous thrombosis (VT). In both stasis VT and non-stasis VT, NIRF microscopy showed that FTP11 fibrin binding was thrombus age-dependent. FTP11 localized to the luminal surface of early-stage VT, but only minimally to subacute VT (p<0.001). Transmission electron microscopy of early stage VT revealed direct blood cell contact with luminal fibrin-rich surfaces. In contrast, subacute VT exhibited an encasing CD31+ neoendothelial layer that limited blood cell contact with thrombus fibrin in both VT models. Next we developed a theranostic strategy to predict fibrinolytic efficacy based on the in vivo fibrin accessibility to blood NIRF signal. Mice with variably aged VT underwent FTP11 injection and intravital microscopy (IVM), followed by tissue plasminogen activator infusion to induce VT fibrinolysis. Fibrin molecular IVM revealed that early stage VT, but not subacute VT, bound FTP11 (p<0.05), and experienced higher rates of fibrinolysis and total fibrinolysis (p<0.05 vs. subacute VT). Before fibrinolysis, the baseline FTP11 NIRF signal predicted the net fibrinolysis at 60 minutes (p<0.001). Taken together, these data provide novel insights into the temporal evolution of VT and its susceptibility to therapeutic fibrinolysis. Fibrin molecular imaging may provide a theranostic strategy to identify venous thrombi amenable to fibrinolytic therapies. PMID:26516370
Effect of exercise training on ventilatory efficiency in patients with heart disease: a review.
Prado, D M L; Rocco, E A; Silva, A G; Rocco, D F; Pacheco, M T; Furlan, V
2016-06-20
The analysis of ventilatory efficiency in cardiopulmonary exercise testing has proven useful for assessing the presence and severity of cardiorespiratory diseases. During exercise, efficient pulmonary gas exchange is characterized by uniform matching of lung ventilation with perfusion. By contrast, mismatching is marked by inefficient pulmonary gas exchange, requiring increased ventilation for a given CO2 production. The etiology of increased and inefficient ventilatory response to exercise in heart disease is multifactorial, involving both peripheral and central mechanisms. Exercise training has been recommended as non-pharmacological treatment for patients with different chronic cardiopulmonary diseases. In this respect, previous studies have reported improvements in ventilatory efficiency after aerobic exercise training in patients with heart disease. Against this background, the primary objective of the present review was to discuss the pathophysiological mechanisms involved in abnormal ventilatory response to exercise, with an emphasis on both patients with heart failure syndrome and coronary artery disease. Secondly, special focus was dedicated to the role of aerobic exercise training in improving indices of ventilatory efficiency among these patients, as well as to the underlying mechanisms involved.
Obesity: challenges to ventilatory control during exercise--a brief review.
Babb, Tony G
2013-11-01
Obesity is a national health issue in the US. Among the many physiological changes induced by obesity, it also presents a unique challenge to ventilatory control during exercise due to increased metabolic demand of moving larger limbs, increased work of breathing due to extra weight on the chest wall, and changes in breathing mechanics. These challenges to ventilatory control in obesity can be inconspicuous or overt among obese adults but for the most part adaptation of ventilatory control during exercise in obesity appears remarkably unnoticed in the majority of obese people. In this brief review, the changes to ventilatory control required for maintaining normal ventilation during exercise will be examined, especially the interaction between respiratory neural drive and ventilation. Also, gaps in our current knowledge will be discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Avoidance of Timeout from Response-Independent Food: Effects of Delivery Rate and Quality
ERIC Educational Resources Information Center
Richardson, Joseph V.; Baron, Alan
2008-01-01
In three experiments, a rat's lever presses could postpone timeouts from food pellets delivered on response-independent schedules. In Experiment 1, the pellets were delivered at variable-time (VT) rates ranging from VT 0.5 to VT 8 min. Experiment 2 replicated the VT 1 min and VT 8 min conditions of Experiment 1 with new subjects. Finally, subjects…
Physiological differences between cycling and running: lessons from triathletes.
Millet, Gregoire P; Vleck, V E; Bentley, D J
2009-01-01
The purpose of this review was to provide a synopsis of the literature concerning the physiological differences between cycling and running. By comparing physiological variables such as maximal oxygen consumption (V O(2max)), anaerobic threshold (AT), heart rate, economy or delta efficiency measured in cycling and running in triathletes, runners or cyclists, this review aims to identify the effects of exercise modality on the underlying mechanisms (ventilatory responses, blood flow, muscle oxidative capacity, peripheral innervation and neuromuscular fatigue) of adaptation. The majority of studies indicate that runners achieve a higher V O(2max) on treadmill whereas cyclists can achieve a V O(2max) value in cycle ergometry similar to that in treadmill running. Hence, V O(2max) is specific to the exercise modality. In addition, the muscles adapt specifically to a given exercise task over a period of time, resulting in an improvement in submaximal physiological variables such as the ventilatory threshold, in some cases without a change in V O(2max). However, this effect is probably larger in cycling than in running. At the same time, skill influencing motor unit recruitment patterns is an important influence on the anaerobic threshold in cycling. Furthermore, it is likely that there is more physiological training transfer from running to cycling than vice versa. In triathletes, there is generally no difference in V O(2max) measured in cycle ergometry and treadmill running. The data concerning the anaerobic threshold in cycling and running in triathletes are conflicting. This is likely to be due to a combination of actual training load and prior training history in each discipline. The mechanisms surrounding the differences in the AT together with V O(2max) in cycling and running are not largely understood but are probably due to the relative adaptation of cardiac output influencing V O(2max) and also the recruitment of muscle mass in combination with the oxidative capacity of this mass influencing the AT. Several other physiological differences between cycling and running are addressed: heart rate is different between the two activities both for maximal and submaximal intensities. The delta efficiency is higher in running. Ventilation is more impaired in cycling than in running. It has also been shown that pedalling cadence affects the metabolic responses during cycling but also during a subsequent running bout. However, the optimal cadence is still debated. Central fatigue and decrease in maximal strength are more important after prolonged exercise in running than in cycling.
Influence of humic acid on adsorption of Hg(II) by vermiculite.
do Nascimento, Fernando Henrique; Masini, Jorge Cesar
2014-10-01
Geochemical mobility of Hg(II) species is strongly affected by the interactions of these compounds with naturally occurring adsorbents such as humic acids, clay minerals, oxides, etc. Interactions among these sorbents affect their affinity for Hg(II) and a full understanding of these processes is still lacking. The present work describes the influence of a humic acid (HA) sample on the adsorption of Hg(II) by vermiculite (VT). Adsorption isotherms were constructed to evaluate the affinity of Hg(II) by VT, HA, VT modified with humic acid (VT-HA), and VT-HA in presence of soluble humic acid (VT-HA + HA). All experiments were made at pH 6.0 ± 0.1 in 0.02 M NaNO3 and 25.0 ± 0.5 °C for initial Hg(II) concentrations from 1.0 to 100 μM. Determinations of Hg(II) were made by square wave voltammetry automated by sequential injection analysis, an approach that enables the determination of the free plus labile fractions of Hg(II) in HA suspensions without the need for laborious separation steps. The adsorption isotherms were fitted to Langmuir and Freundlich equations, showing that HA was the material with the higher adsorption capacity (537 ± 30 μmol g(-1)) in comparison with VT and VT-HA (44 ± 3 and 51 ± 11 μmol g(-1), respectively). Adsorption order was HA > VT-HA + HA > VT = VT-HA. At pH 6.0 the interaction of HA with VT is weak and only 14% of C initially added to the suspension was effectively retained by the mineral. Desorption of Hg(II) in acidic medium (0.05 M HCl) was higher in binary (VT-HA) and ternary (VT-HA + HA) systems in comparison with that of VT and HA alone, suggesting that interactions between VT and HA are facilitated in acidic medium, weakening the binding to Hg(II). Copyright © 2014 Elsevier Ltd. All rights reserved.
The association of statin therapy with the risk of recurrent venous thrombosis.
Smith, N L; Harrington, L B; Blondon, M; Wiggins, K L; Floyd, J S; Sitlani, C M; McKnight, B; Larson, E B; Rosendaal, F R; Heckbert, S R; Psaty, B M
2016-07-01
Essentials A lowered risk of recurrent venous thrombosis (VT) with statin treatment is controversial. Among observational inception cohort of 2,798 adults with incident VT, 457 had recurrent VT. Time-to-event models with time-varying statin use and adjustment for potential confounders was used for analysis. Compared to nonuse, current statin use was associated with 26% lower risk of recurrent VT. Click to hear Prof. Büller's perspective on Anticoagulant Therapy in the Treatment of Venous Thromboembolism Background Meta-analyses of randomized controlled trials suggest that treatment with hydroxymethylglutaryl-coenzyme A reductase inhibitors (statins) lowers the risk of incident venous thrombosis (VT), particularly among those without prevalent clinical cardiovascular disease (CVD). Whether this is true for the prevention of recurrent VT is debated. We used an observational inception cohort to estimate the association of current statin use with the risk of recurrent VT. Methods and Results The study setting was a large healthcare organization with detailed medical record and pharmacy information at cohort entry and throughout follow-up. We followed 2798 subjects 18-89 years of age who experienced a validated incident VT between January 1, 2002, and December 31, 2010, for a first recurrent VT, validated by medical record review. During follow-up, 457 (16%) developed a first recurrent VT. In time-to-event models incorporating time-varying statin use and adjusting for potential confounders, current statin use was associated with a 26% lower risk of recurrent VT: hazard ratio 0.74, 95% confidence interval 0.59-0.94. Among cohort members free of CVD (n = 2134), current statin use was also associated with a lower risk (38%) of recurrent VT: hazard ratio 0.62, 95% confidence interval 0.45-0.85. We found similar results when restricting to new users of statins and in subgroups of different statin types and doses. Conclusions In a population-based cohort of subjects who had experienced an incident VT, statin use, compared with nonuse, was associated with a clinically relevant lower risk of recurrent VT. These findings suggest a potential secondary benefit of statins among patients who have experienced an incident VT. © 2016 International Society on Thrombosis and Haemostasis.
Diagnosis and ablation of multiform fascicular tachycardia.
Sung, Raphael K; Kim, Albert M; Tseng, Zian H; Han, Frederick; Inada, Keiichi; Tedrow, Usha B; Viswanathan, Mohan N; Badhwar, Nitish; Varosy, Paul D; Tanel, Ronn; Olgin, Jeffrey E; Stephenson, William G; Scheinman, Melvin
2013-03-01
Fascicular tachycardia (FT) is an uncommon cause of monomorphic sustained ventricular tachycardia (VT). We describe 6 cases of FT with multiform QRS morphologies. Six of 823 consecutive VT cases were retrospectively analyzed and found attributable to FT with multiform QRS patterns, with 3 cases exhibiting narrow QRS VT as well. All underwent electrophysiology study including fascicular potential mapping, entrainment pacing, and electroanatomic mapping. The first 3 cases describe similar multiform VT patterns with successful ablation in the upper mid septum. Initially, a right bundle branch block (RBBB) VT with superior axis was induced. Radiofrequency catheter ablation (RFCA) targeting the left posterior fascicle (LPF) resulted in a second VT with RBBB inferior axis. RFCA in the upper septum just apical to the LBB potential abolished VT in all cases. Cases 4 and 5 showed RBBB VT with alternating fascicular block compatible with upper septal dependent VT, resulting in bundle branch reentrant VT (BBRT) after ablation of LPF and left anterior fascicle (LAF). Finally, Cases 5 and 6 demonstrated spontaneous shift in QRS morphology during VT, implicating participation of a third fascicle. In Case 6, successful ablation was achieved over the proximal LAF, likely representing insertion of the auxiliary fascicle near the proximal LAF. Multiform FTs show a reentrant mechanism using multiple fascicular branches. We hypothesize that retrograde conduction over the septal fascicle produces alternate fascicular patterns as well as narrow VT forms. Ablation of the respective fascicle was successful in abolishing FT but does not preclude development of BBRT unless septal fascicle is targeted and ablated. © 2012 Wiley Periodicals, Inc.
Do, Duc H; Bradfield, Jason; Ajijola, Olujimi A; Vaseghi, Marmar; Le, John; Rahman, Siamak; Mahajan, Aman; Nogami, Akihiko; Boyle, Noel G; Shivkumar, Kalyanam
2017-10-27
Novel therapies aimed at modulating the autonomic nervous system, including thoracic epidural anesthesia (TEA), have been shown in small case series to be beneficial in treating medically refractory ventricular tachycardia (VT) storm. However, it is not clear when these options should be considered. We reviewed a multicenter experience with TEA in the management of VT storm to determine its optimal therapeutic use. Data for 11 patients in whom TEA was instituted for VT storm between July 2005 and March 2016 were reviewed to determine the clinical characteristics, outcomes, and role in management. The clinical presentation was incessant VT in 7 (64%), with polymorphic VT in 3 (27%) and monomorphic VT in 8 (73%). The underlying conditions were nonischemic cardiomyopathy in 5 (45%), ischemic cardiomyopathy in 3 (27%), and hypertrophic cardiomyopathy, Brugada syndrome, and cardiac lipoma in 1 (9%) each. Five (45%) had a complete and 1 (9%) had a partial response to TEA; 4 of the complete responders had incessant VT. All 4 patients with a documented response to deep sedation demonstrated a complete response to TEA. More than half of the patients with VT storm in our series responded to TEA. TEA may be effective and should be considered as a therapeutic option in patients with VT storm, especially incessant VT, who are refractory to initial management. Improvement in VT burden with deep sedation may suggest that sympathoexcitation plays a key role in perpetuating VT and predict a positive response to TEA. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Gopinathannair, Rakesh; Chaudhary, Ashok K; Xing, Dezhi; Ely, Debra; Zheng, Wei; Martins, James B
2009-11-01
Ischemic focal ventricular tachycardia (VT) occurs in animals and humans. Angiotensin-converting enzyme inhibitors and receptor blockers reduce sudden death in patients with ischemic heart disease. In our dog model of coronary artery occlusion (CAO), we tested the hypothesis that angiotensin II (AGII) will selectively promote focal VT and that the specific AT(2) blocker PD-123319 (PD), or AT(1) blocker losartan, will affect this VT. Anesthetized dogs (n = 90) underwent CAO, followed by three-dimensional activation mapping of inducible VT. Dogs without VT in 1-3 h after CAO received AGII, and those with VT received either PD or losartan. Focal endocardium excised from ischemic sites was studied in vitro with standard microelectrode. Of 33 dogs with no inducible VT, AGII infusion resulted in sustained VT of only focal Purkinje origin in 13 (39%) compared with 0 of 20 dogs with saline. Of 26 dogs with inducible VT at baseline, given PD, reinduction was blocked in 8 of 10 (P < 0.05) focal VT, but only 1 of 15 with reentry. In contrast, of 11 dogs given losartan, reinduction of either mechanism was not blocked. In vitro triggered activity in Purkinje was blocked by PD in 13 of 19 (P < 0.05), but not by losartan in 8. Also, triggered activity was promoted by AGII, losartan, or the combination in 9 of 12 tissues. AGII promotes only focal, mainly Purkinje ischemic VT. PD, but not losartan, preferentially blocked focal VT, which is likely due to triggered activity due to delayed afterdepolarizations in Purkinje.
Herraiz, Sonia; Novella-Maestre, Edurne; Rodríguez, Beatriz; Díaz, César; Sánchez-Serrano, María; Mirabet, Vicente; Pellicer, Antonio
2014-03-01
To compare slow freezing (SF) with four vitrification techniques (VT) for cryopreservation of ovarian tissue (OT) and to evaluate the best protocol for human OT in a xenograft model. Experimental study. University hospital. Patients undergoing fertility preservation. Ovariectomized nude mice. Cryopreservation of bovine OT after SF and four VTs (VT1, VT2, VT3, and VT4) by combining two cryoprotectant vitrification solutions (VS1 and VS2) and two devices (metallic grid and ethyl vinyl acetate bag), after which the cryopreservation of human OT by SF and VT1 and xenograft into nude mice. Follicular densities, proliferation, vascularization, fibrosis, apoptosis, tissue viability. The in vitro study in bovine OT showed a lower percentage of quiescent follicles in the SF group but not in the vitrification groups (VT1-VT4). Apoptosis increased and cell proliferation decreased in all the experimental groups except VT1 (20% ethylene glycol, 20% dimethyl sulfoxide, 0.5 M sucrose, and 20% synthetic serum substitute in HEPES-buffered M199 culture media with Cryotissue metallic grids). Tissue viability was diminished in VT3, and the SF-xenografted human samples showed reduced primordial and secondary densities and unbalanced follicular populations when compared with fresh and VT1 tissue. VT1 offers similar conditions to fresh tissue for follicular density, proliferation, viability, and cell death and preserves a larger population of quiescent follicles than SF after transplantation, thus ensuring the maintenance of graft potential fertility. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Selvam, R; Jurkevich, A; Kang, S W; Mikhailova, M V; Cornett, L E; Kuenzel, W J
2013-01-01
The neurohormone arginine vasotocin (AVT) in non mammalian vertebrates is homologous to arginine vasopressin (AVP) in mammals. Its actions are mediated via G protein-coupled receptors that belong to the vasotocin/mesotocin family. Because of the known regulatory effects of nonapeptide hormones on anterior pituitary functions, receptor subtypes in that family have been proposed to be located in anterior pituitary cells. Recently, an avian vasotocin receptor subtype designated VT4R has been cloned, which shares 69% sequence homology with a human vasopressin receptor, the V1aR. In the present study, a polyclonal antibody to the VT4R was developed and validated to confirm its specificity to the VT4R. The antibody was used to test the hypothesis that the VT4R is present in the avian anterior pituitary and is specifically associated with certain cell types, where its expression is modulated by acute stress. Western blotting of membrane protein extracts from pituitary tissue, the use of HeLa cells transfected with the VT4R and peptide competition assays all confirmed the specificity of the antibody to the VT4R. Dual-labelling immunofluorescence microscopy was utilised to identify pituitary cell types that contained immunoreactive VT4R. The receptor was found to be widely distributed throughout the cephalic lobe but not in the caudal lobe of the anterior pituitary. Immunoreactive VT4R was associated with corticotrophs. Approximately 89% of immunolabelled corticotrophs were shown to contain the VT4R. The immunoreactive VT4R was not found in gonadotrophs, somatotrophs or lactotrophs. To determine a possible functional role of the VT4R and previously characterised VT2R, gene expression levels in the anterior pituitary were determined after acute immobilisation stress by quantitative reverse transcriptase-polymerase chain reaction. The results showed a significant increase in plasma corticosterone levels (three- to four-fold), a significant reduction of VT4R mRNA and an increase of VT2R mRNA (P < 0.05) in acutely immobilised chicks compared to controls. The data suggest a role of the VT4R in the avian stress response. © 2012 British Society for Neuroendocrinology.
You, J S; Park, S; Chung, S P; Park, J W
2009-03-01
A needle thoracocentesis should be performed with maximal safety and optimal efficacy in mind. Mobile video telephony (VT) could be used to facilitate instructions for the accurate performance of needle thoracocentesis in an emergency setting. This new communication method will increase the accuracy of identifying the relevant anatomical site during the decompression technique. A prospective randomised manikin study was performed to investigate the effectiveness of using VT as a method of instruction for the identification of anatomical landmarks during the performance of needle thoracocentesis. The overall success rate was significantly higher in the VT group which performed needle thoracocentesis under the guidance of VT than in the non-VT group who performed the procedure without VT-aided instruction. The instrument difficulty score and procedure satisfaction score were significantly lower in the VT group than in the non-VT group. Identification of the correct anatomical landmark for needle thoracocentesis can be performed with instructions provided via VT because a dispatcher can monitor every step and provide correct instructions. This new technology will improve critical care medicine.
Zinn, Caryn; Wood, Matthew; Williden, Mikki; Chatterton, Simon; Maunder, Ed
2017-01-01
Low-carbohydrate, high-fat and ketogenic diets are increasingly adopted by athletes for body composition and sports performance enhancements. However, as yet, there is no consensus on their efficacy in improving performance. There is also no comprehensive literature on athletes' experiences while undertaking this diet. The purpose of this pilot work was two-fold: i. to examine the effects of a non-calorie controlled ketogenic diet on body composition and performance outcomes of endurance athletes, and ii. to evaluate the athletes' experiences of the ketogenic diet during the 10-week intervention. Using a case study design, five New Zealand endurance athletes (4 females, 1 male) underwent a 10-week ketogenic dietary intervention. Body composition (sum of 8 skinfolds), performance indicators (time to exhaustion, VO 2 max, peak power and ventilatory threshold), and gas exchange thresholds were measured at baseline and at 10 weeks. Mean change scores were calculated, and analysed using t-tests; Cohen's effect sizes and 90% confidence limits were applied to quantify change. Individual interviews conducted at 5 weeks and a focus group at 10 weeks assessed athletes' ketogenic diet experiences. Data was transcribed and analysed using thematic analysis. All athletes increased their ability to utilise fat as a fuel source, including at higher exercise intensities. Mean body weight was reduced by 4 kg ± SD 3.1 ( p = 0.046; effect size (ES):0.62), and sum of 8 skinfolds by 25.9 mm ± SD 6.9; ES: 1.27; p = 0.001). Mean time to exhaustion dropped by ~2 min (±SD 0.7; p = 0.004; ES: 0.53). Other performance outcomes showed mean reductions, with some increases or unchanged results in two individuals (VO2 Max: -1.69 ml.kg.min ± SD 3.4 ( p = 0.63); peak power: -18 W ± SD 16.4 ( p = 0.07), and VT2: -6 W ± SD 44.5 ( p = 0.77). Athletes reported experiencing reduced energy levels initially, followed by a return of high levels thereafter, especially during exercise, but an inability to easily undertake high intense bouts. Each athlete reported experiencing enhanced well-being, included improved recovery, improvements in skin conditions and reduced inflammation. Despite performance decrements and some negative experiences, athletes were keen to pursue a modified low-carbohydrate, high-fat eating style moving forward due to the unexpected health benefits they experienced. ACTRN: ACTRN12617000613303. Registered 28 April 2017, retrospectively registered.
Kimura, Satoko; Ohi, Yoshiaki; Haji, Akira
2015-04-15
Ventilatory disturbance is a fatal side-effect of opioid analgesics. Separation of analgesia from ventilatory depression is important for therapeutic use of opioids. It has been suggested that opioid-induced ventilatory depression results from a decrease in adenosine 3',5'-cyclic monophosphate content in the respiratory-related neurons. Therefore, we examined the effects of caffeine, a methylxanthine non-selective phosphodiesterase (PDE) inhibitor with adenosine antagonistic activity, and rolipram, a racetam selective PDE4 inhibitor, on ventilatory depression induced by morphine. Spontaneous ventilation and paw withdrawal responses to nociceptive thermal stimulation were measured in anesthetized rats simultaneously. The efferent discharge of the phrenic nerve was recorded in anesthetized, vagotomized, paralyzed and artificially ventilated rats. Rolipram (0.1 and 0.3 mg/kg, i.v.) and caffeine (3.0 and 10.0 mg/kg, i.v.) relieved morphine (1.0 mg/kg, i.v.)-induced ventilatory depression but had no discernible effect on its analgesic action. Rolipram (0.3 and 1.0 mg/kg, i.v.) and caffeine (10.0 and 20.0 mg/kg, i.v.) recovered morphine (3.0 mg/kg, i.v.)-induced prolongation and flattening of inspiratory discharge in the phrenic nerve. Inhibition of PDE4 may be a possible approach for overcoming morphine-induced ventilatory depression without loss of analgesia. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Yongxun; Matsukawa, Takashi; Endo, Kazuhiko; O'uchi, Shinichi; Tsukada, Junichi; Yamauchi, Hiromi; Ishikawa, Yuki; Mizubayashi, Wataru; Morita, Yukinori; Migita, Shinji; Ota, Hiroyuki; Masahara, Meishoku
2014-01-01
Three-dimensional (3D) fin-channel charge trapping (CT) flash memories with different gate materials of physical-vapor-deposited (PVD) titanium nitride (TiN) and n+-polycrystalline silicon (poly-Si) have successfully been fabricated by using (100)-oriented silicon-on-insulator (SOI) wafers and orientation-dependent wet etching. Electrical characteristics of the fabricated flash memories including statistical threshold voltage (Vt) variability, endurance, and data retention have been comparatively investigated. It was experimentally found that a larger memory window and a deeper erase are obtained in PVD-TiN-gated metal-oxide-nitride-oxide-silicon (MONOS)-type flash memories than in poly-Si-gated poly-Si-oxide-nitride-oxide-silicon (SONOS)-type memories. The larger memory window and deeper erase of MONOS-type flash memories are contributed by the higher work function of the PVD-TiN metal gate than of the n+-poly-Si gate, which is effective for suppressing electron back tunneling during erase operation. It was also found that the initial Vt roll-off due to the short-channel effect (SCE) is directly related to the memory window roll-off when the gate length (Lg) is scaled down to 46 nm or less.
Vainshelboim, Baruch; Oliveira, Jose; Fox, Benjamin Daniel; Kramer, Mordechai Reuven
2016-08-01
Idiopathic pulmonary fibrosis (IPF) is a chronic, progressive, and fatal interstitial lung disease associated with poor prognosis and limited effective treatment options. Reliable predictors of outcome in daily clinical practice are needed to determine high-risk patients for urgent lung transplantation referral. This study aimed to identify practical prognostic predictors of mortality using cardiopulmonary exercise testing (CPET) in IPF subjects. Thirty-four subjects with IPF (22 men and 12 women), median age 68 (range 50-81) y were prospectively studied. At baseline, all subjects were assessed with CPET and were followed up for 40 months from baseline. Receiver operating characteristic curve analysis was conducted to determine cut-off points of CPET variables for mortality, Cox regression analysis for survival using a log-rank test, and hazard ratio for death using a Wald test. Peak work rate <62 watts (P = .005), peak V̇O2 ≤13.8 mL/kg/min (P = .031), tidal volume reserve ≤0.48 L/breath (P = .010), minute ventilation to carbon dioxide (V̇E)/V̇CO2 ) ratio at the anaerobic threshold >34 (P = .02), and V̇E)/V̇O2 nadir >34 (P = .002) were detected as cut-off points associated with mortality. Non-survivor subjects were characterized by higher dyspnea levels, the presence of pulmonary hypertension assessed by echocardiography, pronounced inefficient ventilatory pattern, lower exercise capacity, and more severe desaturation during physical exertion. By the end of the study, 11 subjects (7 women and 4 men) died. Overall mean survival was 60%, 33.7 months (95% CI 30.2-37.2). This study provides simple, practical, and novel cut-off points for CPET as predictors of prognosis to identify high-risk IPF subjects. Impairment in exercise capacity and abnormal ventilatory responses during CPET were associated with poorer survival in IPF subjects. The findings suggest considering the use of CPET for IPF risk stratification and prediction of prognosis. (ClinicalTrials.gov registration NCT01499745.). Copyright © 2016 by Daedalus Enterprises.
Rosman, Jonathan; Hanon, Sam; Shapiro, Michael; Evans, Steven J; Schweitzer, Paul
2006-04-01
The mechanisms underlying the initiation of sustained ventricular tachycardia (VT) have not been fully elucidated. The extent to which reentry, abnormal automaticity, and triggered activity play a role in VT differs depending on the etiology of left ventricular dysfunction. By analyzing electrograms from implantable cardioverter defibrillator (ICD), we sought to determine whether there were differences in VT initiation patterns between patients with ischemic and nonischemic cardiomyopathy. We analyzed ICD electrograms in patients with ejection fractions < 40% who had sustained VT over a 27-month period. The trigger for VT onset was classified as a ventricular premature beat (VPB), supraventricular tachycardia, or of "sudden onset." The baseline cycle length, VT cycle length, coupling interval, and prematurity ratio were recorded for each event. The prematurity ratio was calculated as the coupling interval of the VT initiator divided by the baseline cycle length. Sixty-three VT events in 14 patients met the inclusion criteria. A VPB initiated the VT in 58 episodes (92%), 1 episode (2%) was initiated by a supraventricular tachycardia, and 4 episodes (6%) were sudden onset. The prematurity ratio was significantly higher (P < 0.05) in patients with ischemic cardiomyopathy (0.751 +/- 0.068) as compared to patients with nonischemic cardiomyopathy (0.604 +/- 0.139). VPBs initiated most sustained VT episodes. A significantly higher prematurity ratio was observed in the ischemic heart disease group. This may represent different mechanisms of VT initiation in patients with ischemic versus nonischemic heart disease.
Ventilatory drive and the apnea-hypopnea index in six-to-twelve year old children
Fregosi, Ralph F; Quan, Stuart F; Jackson, Andrew C; Kaemingk, Kris L; Morgan, Wayne J; Goodwin, Jamie L; Reeder, Jenny C; Cabrera, Rosaria K; Antonio, Elena
2004-01-01
Background We tested the hypothesis that ventilatory drive in hypoxia and hypercapnia is inversely correlated with the number of hypopneas and obstructive apneas per hour of sleep (obstructive apnea hypopnea index, OAHI) in children. Methods Fifty children, 6 to 12 years of age were studied. Participants had an in-home unattended polysomnogram to compute the OAHI. We subsequently estimated ventilatory drive in normoxia, at two levels of isocapnic hypoxia, and at three levels of hyperoxic hypercapnia in each subject. Experiments were done during wakefulness, and the mouth occlusion pressure measured 0.1 seconds after inspiratory onset (P0.1) was measured in all conditions. The slope of the relation between P0.1 and the partial pressure of end-tidal O2 or CO2 (PETO2 and PETCO2) served as the index of hypoxic or hypercapnic ventilatory drive. Results Hypoxic ventilatory drive correlated inversely with OAHI (r = -0.31, P = 0.041), but the hypercapnic ventilatory drive did not (r = -0.19, P = 0.27). We also found that the resting PETCO2 was significantly and positively correlated with the OAHI, suggesting that high OAHI values were associated with resting CO2 retention. Conclusions In awake children the OAHI correlates inversely with the hypoxic ventilatory drive and positively with the resting PETCO2. Whether or not diminished hypoxic drive or resting CO2 retention while awake can explain the severity of sleep-disordered breathing in this population is uncertain, but a reduced hypoxic ventilatory drive and resting CO2 retention are associated with sleep-disordered breathing in 6–12 year old children. PMID:15117413
Increased ventilatory response to carbon dioxide in COPD patients following vitamin C administration
Hartmann, Sara E.; Kissel, Christine K.; Szabo, Lian; Walker, Brandie L.; Leigh, Richard; Anderson, Todd J.
2015-01-01
Patients with chronic obstructive pulmonary disease (COPD) have decreased ventilatory and cerebrovascular responses to hypercapnia. Antioxidants increase the ventilatory response to hypercapnia in healthy humans. Cerebral blood flow is an important determinant of carbon dioxide/hydrogen ion concentration at the central chemoreceptors and may be affected by antioxidants. It is unknown whether antioxidants can improve the ventilatory and cerebral blood flow response in individuals in whom these are diminished. Thus, we aimed to determine the effect of vitamin C administration on the ventilatory and cerebrovascular responses to hypercapnia during healthy ageing and in COPD. Using transcranial Doppler ultrasound, we measured the ventilatory and cerebral blood flow responses to hyperoxic hypercapnia before and after an intravenous vitamin C infusion in healthy young (Younger) and older (Older) subjects and in moderate COPD. Vitamin C increased the ventilatory response in COPD patients (mean (95% CI) 1.1 (0.9–1.1) versus 1.5 (1.1–2.0) L·min−1·mmHg−1, p<0.05) but not in Younger (2.5 (1.9–3.1) versus 2.4 (1.9–2.9) L·min−1·mmHg−1, p>0.05) or Older (1.3 (1.0–1.7) versus 1.3 (1.0–1.7) L·min−1·mmHg−1, p>0.05) healthy subjects. Vitamin C did not affect the cerebral blood flow response in the young or older healthy subjects or COPD subjects (p>0.05). Vitamin C increases the ventilatory but not cerebrovascular response to hyperoxic hypercapnia in patients with moderate COPD. PMID:27730137
Santangeli, Pasquale; Zado, Erica S; Supple, Gregory E; Haqqani, Haris M; Garcia, Fermin C; Tschabrunn, Cory M; Callans, David J; Lin, David; Dixit, Sanjay; Hutchinson, Mathew D; Riley, Michael P; Marchlinski, Francis E
2015-12-01
Catheter ablation of ventricular tachycardia (VT) in arrhythmogenic right ventricular cardiomyopathy improves short-term VT-free survival. We sought to determine the long-term outcomes of VT control and need for antiarrhythmic drug therapy after endocardial (ENDO) and adjuvant epicardial (EPI) substrate modification in patients with arrhythmogenic right ventricular cardiomyopathy. We examined 62 consecutive patients with Task Force criteria for arrhythmogenic right ventricular cardiomyopathy referred for VT ablation with a minimum follow-up of 1 year. Catheter ablation was guided by activation/entrainment mapping for tolerated VT and pacemapping/targeting of abnormal substrate for unmappable VT. Adjuvant EPI ablation was performed when recurrent VT or persistent inducibility after ENDO-only ablation. Endocardial plus adjuvant EPI ablation was performed in 39 (63%) patients, including 13 who crossed over to ENDO-EPI after VT recurrence during follow-up, after ENDO-only ablation. Before ablation, 54 of 62 patients failed a mean of 2.4 antiarrhythmic drugs, including amiodarone in 29 (47%) patients. During follow-up of 56±44 months after the last ablation, VT-free survival was 71% with only a single VT episode in additional 9 patients (15%). At last follow-up, 39 (64%) patients were only on β-blockers or no treatment, 21 were on class 1 or 3 antiarrhythmic drugs (11 for atrial arrhythmias), and 2 were on amiodarone as a bridge to heart transplantation. The long-term outcome after ENDO and adjuvant EPI substrate ablation of VT in arrhythmogenic right ventricular cardiomyopathy is good. Most patients have complete VT control without amiodarone therapy and limited need for antiarrhythmic drugs. © 2015 American Heart Association, Inc.
Di Biase, Luigi; Tung, Roderick; Szili-Torok, Tamás; Burkhardt, J David; Weiss, Peter; Tavernier, Rene; Berman, Adam E; Wissner, Erik; Spear, William; Chen, Xu; Neužil, Petr; Skoda, Jan; Lakkireddy, Dhanunjaya; Schwagten, Bruno; Lock, Ken; Natale, Andrea
2017-04-01
Patients with ischemic cardiomyopathy (ICM) are prone to scar-related ventricular tachycardia (VT). The success of VT ablation depends on accurate arrhythmogenic substrate localization, followed by optimal delivery of energy provided by constant electrode-tissue contact. Current manual and remote magnetic navigation (RMN)-guided ablation strategies aim to identify a reentry circuit and to target a critical isthmus through activation and entrainment mapping during ongoing tachycardia. The MAGNETIC VT trial will assess if VT ablation using the Niobe™ ES magnetic navigation system results in superior outcomes compared to a manual approach in subjects with ischemic scar VT and low ejection fraction. This is a randomized, single-blind, prospective, multicenter post-market study. A total of 386 subjects (193 per group) will be enrolled and randomized 1:1 between treatment with the Niobe ES system and treatment via a manual procedure at up to 20 sites. The study population will consist of patients with ischemic cardiomyopathy with left ventricular ejection fraction (LVEF) of ≤35% and implantable cardioverter defibrillator (ICD) who have sustained monomorphic VT. The primary study endpoint is freedom from any recurrence of VT through 12 months. The secondary endpoints are acute success; freedom from any VT at 1 year in a large-scar subpopulation; procedure-related major adverse events; and mortality rate through 12-month follow-up. Follow-up will consist of visits at 3, 6, 9, and 12 months, all of which will include ICD interrogation. The MAGNETIC VT trial will help determine whether substrate-based ablation of VT with RMN has clinical advantages over manual catheter manipulation. Clinicaltrials.gov identifier: NCT02637947.
Muser, Daniele; Santangeli, Pasquale; Pathak, Rajeev K; Castro, Simon A; Liang, Jackson J; Magnani, Silvia; Hayashi, Tatsuya; Garcia, Fermin C; Hutchinson, Mathew D; Supple, Gregory E; Frankel, David S; Riley, Michael P; Lin, David; Schaller, Robert D; Desjardins, Benoit; Dixit, Sanjay; Callans, David J; Zado, Erica S; Marchlinski, Francis E
2016-08-01
Catheter ablation (CA) of ventricular tachycardia (VT) in patients with cardiac sarcoidosis can be challenging because of the complex underlying substrate. We sought to determine the long-term outcome of CA of VT in patients with cardiac sarcoidosis. We enrolled 31 patients (age, 55±10 years) with diagnosis of cardiac sarcoidosis based on Heart Rhythm Society criteria and VT who underwent CA. In 23 (74%) patients, preprocedure cardiac magnetic resonance imaging and positron emission tomographic (PET) evaluation were performed. Preprocedure magnetic resonance imaging was positive for late gadolinium enhancement in 21 of 23 (91%) patients, whereas abnormal 18-fluorodeoxyglucose uptake was found in 15 of 23 (65%) cases. In 14 of 15 patients with positive PET at baseline, PET was repeated after 6.1±3.7-month follow-up. After a median follow-up of 2.5 (range, 0-10.5) years, 1 (3%) patient died and 4 (13%) underwent heart transplant. Overall VT-free survival was 55% at 2-year follow-up. Among the 16 (52%) patients with VT recurrences, CA resulted in a significant reduction of VT burden, with 8 (50%) having only isolated (1-3) VT episodes and only 1 patient with recurrent VT storm. The presence of late gadolinium enhancement at magnetic resonance imaging, a positive PET at baseline, and lack of PET improvement over follow-up were associated with increased risk of recurrent VT. In patients with cardiac sarcoidosis and VT, CA is effective in achieving long-term freedom from VT or improvement in VT burden in the majority of patients. The presence of late gadolinium enhancement at magnetic resonance imaging, a positive PET scan at baseline, or lack of improvement at repeat PET over follow-up predict worse arrhythmia-free survival. © 2016 American Heart Association, Inc.
Pre-Clinical Model to Study Recurrent Venous Thrombosis in the Inferior Vena Cava.
Andraska, Elizabeth A; Luke, Catherine E; Elfline, Megan A; Henke, Samuel P; Madapoosi, Siddharth S; Metz, Allan K; Hoinville, Megan E; Wakefield, Thomas W; Henke, Peter K; Diaz, Jose A
2018-06-01
Patients undergoing deep vein thrombosis (VT) have over 30% recurrence, directly increasing their risk of post-thrombotic syndrome. Current murine models of inferior vena cava (IVC) VT model host one thrombosis event. We aimed to develop a murine model to study IVC recurrent VT in mice. An initial VT was induced using the electrolytic IVC model (EIM) with constant blood flow. This approach takes advantage of the restored vein lumen 21 days after a single VT event in the EIM demonstrated by ultrasound. We then induced a second VT 21 days later, using either EIM or an IVC ligation model for comparison. The control groups were a sham surgery and, 21 days later, either EIM or IVC ligation. IVC wall and thrombus were harvested 2 days after the second insult and analysed for IVC and thrombus size, gene expression of fibrotic markers, histology for collagen and Western blot for citrullinated histone 3 (Cit-H3) and fibrin. Ultrasound confirmed the first VT and its progressive resolution with an anatomical channel allowing room for the second thrombus by day 21. As compared with a primary VT, recurrent VT has heavier walls with significant up-regulation of transforming growth factor-β (TGF-β), elastin, interleukin (IL)-6, matrix metallopeptidase 9 (MMP9), MMP2 and a thrombus with high citrullinated histone-3 and fibrin content. Experimental recurrent thrombi are structurally and compositionally different from the primary VT, with a greater pro-fibrotic remodelling vein wall profile. This work provides a VT recurrence IVC model that will help to improve the current understanding of the biological mechanisms and directed treatment of recurrent VT. Schattauer GmbH Stuttgart.
Mayo, P; Volpicelli, G; Lerolle, N; Schreiber, A; Doelken, P; Vieillard-Baron, A
2016-07-01
On a regular basis, the intensivist encounters the patient who is difficult to wean from mechanical ventilatory support. The causes for failure to wean from mechanical ventilatory support are often multifactorial and involve a complex interplay between cardiac and pulmonary dysfunction. A potential application of point of care ultrasonography relates to its utility in the process of weaning the patient from mechanical ventilatory support. This article reviews some applications of ultrasonography that may be relevant to the process of weaning from mechanical ventilatory support. The authors have divided these applications of ultrasonography into four separate categories: the assessment of cardiac, diaphragmatic, and lung function; and the identification of pleural effusion; which can all be evaluated with ultrasonography during a dynamic process in which the intensivist is uniquely positioned to use ultrasonography at the point of care. Ultrasonography may have useful application during the weaning process from mechanical ventilatory support.
Hausen, Matheus; Soares, Pedro Paulo; Araujo, Marcus Paulo; Esteves, Débora; Julio, Hilbert; Tauil, Roberto; Junca, Marcus; Porto, Flávia; Franchini, Emerson; Bridge, Craig Alan; Gurgel, Jonas
2018-05-10
The purpose of the present study was to propose and validate new taekwondo-specific cardiopulmonary exercise tests. Twelve male national-level taekwondo athletes (age 20 ± 2 yrs; body mass 67.5 ± 5.7 kg; height 175 ± 8 cm; training experience 7 ± 3 yrs) performed three separate exercise tests in a randomized counterbalanced order: 1) a Treadmill Running Cardiopulmonary Exercise Test (CPET); 2) Continuous and 3) Interval Taekwondo Cardiopulmonary Exercise Tests (cTKDet and iTKDet, respectively). The CPET was administered using an individualized ramp protocol. Taekwondo tests comprised sequences of turning kicks performed upon a stationary target. The impacts were recorded via an electronic scoring sensor used in official competition. Stages on the cTKDet and iTKDet lasted 1-min and progressively reduced the kick interval duration. These were guided by a sound signal, starting with 4.6s between kicks and reducing by 0.4s every minute until the test ended. Oxygen uptake (V̇O 2 ), heart rate (HR), capillary blood lactate and ratings of perceived exertion were measured. Modest differences were identified in V̇O 2MAX between the tests (F 2,22 =3.54; p=0.046; ES=0.16). HR MAX was higher during both taekwondo tests (F 2,22 =14.3; p=0.001; ES=1.14) compared with CPET. Specific tests also yielded higher responses in the 1 st ventilatory threshold V̇O 2 (F 2,22 =6.5; p=0.04; ES=0.27) and HR (F 2,22 =12.3; p<0.001; ES=1.06), and HR at the 2 nd ventilatory threshold (F 2,22 =5.7; p=0.02; ES=0.72). Taekwondo-specific cardiopulmonary tests enhance the validity of some cardiopulmonary responses, and might therefore be considered to optimise routine diagnostic testing and training prescription for this athletic group.
Higher fine particulate matter and temperature levels impair exercise capacity in cardiac patients.
Giorgini, Paolo; Rubenfire, Melvyn; Das, Ritabrata; Gracik, Theresa; Wang, Lu; Morishita, Masako; Bard, Robert L; Jackson, Elizabeth A; Fitzner, Craig A; Ferri, Claudio; Brook, Robert D
2015-08-01
Fine particulate matter (PM2.5) air pollution and variations in ambient temperature have been linked to increased cardiovascular morbidity and mortality. However, no large-scale study has assessed their effects on directly measured aerobic functional capacity among high-risk patients. Using a cross-sectional observational design, we evaluated the effects of ambient PM2.5 and temperature levels over 7 days on cardiopulmonary exercise test results performed among 2078 patients enrolling into a cardiac rehabilitation programme at the University of Michigan (from January 2003 to August 2011) using multiple linear regression analyses (controlling for age, sex, body mass index). Peak exercise oxygen consumption was significantly decreased by approximately 14.9% per 10 μg/m(3) increase in ambient PM2.5 levels (median 10.7 μg/m(3), IQR 10.1 μg/m(3)) (lag days 6-7). Elevations in PM2.5 were also related to decreases in ventilatory threshold (lag days 5-7) and peak heart rate (lag days 2-3) and increases in peak systolic blood pressure (lag days 4-5). A 10°C increase in temperature (median 10.5°C, IQR 17.5°C) was associated with reductions in peak exercise oxygen consumption (20.6-27.3%) and ventilatory threshold (22.9-29.2%) during all 7 lag days. In models including both factors, the outcome associations with PM2.5 were attenuated whereas the effects of temperature remained significant. Short-term elevations in ambient PM2.5, even at low concentrations within current air quality standards, and/or higher temperatures were associated with detrimental changes in aerobic exercise capacity, which can be linked to a worse quality of life and cardiovascular prognosis among cardiac rehabilitation patients. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
GEDAE-LaB: A Free Software to Calculate the Energy System Contributions during Exercise
Bertuzzi, Rômulo; Melegati, Jorge; Bueno, Salomão; Ghiarone, Thaysa; Pasqua, Leonardo A.; Gáspari, Arthur Fernandes; Lima-Silva, Adriano E.; Goldman, Alfredo
2016-01-01
Purpose The aim of the current study is to describe the functionality of free software developed for energy system contributions and energy expenditure calculation during exercise, namely GEDAE-LaB. Methods Eleven participants performed the following tests: 1) a maximal cycling incremental test to measure the ventilatory threshold and maximal oxygen uptake (V˙O2max); 2) a cycling workload constant test at moderate domain (90% ventilatory threshold); 3) a cycling workload constant test at severe domain (110% V˙O2max). Oxygen uptake and plasma lactate were measured during the tests. The contributions of the aerobic (AMET), anaerobic lactic (LAMET), and anaerobic alactic (ALMET) systems were calculated based on the oxygen uptake during exercise, the oxygen energy equivalents provided by lactate accumulation, and the fast component of excess post-exercise oxygen consumption, respectively. In order to assess the intra-investigator variation, four different investigators performed the analyses independently using GEDAE-LaB. A direct comparison with commercial software was also provided. Results All subjects completed 10 min of exercise at moderate domain, while the time to exhaustion at severe domain was 144 ± 65 s. The AMET, LAMET, and ALMET contributions during moderate domain were about 93, 2, and 5%, respectively. The AMET, LAMET, and ALMET contributions during severe domain were about 66, 21, and 13%, respectively. No statistical differences were found between the energy system contributions and energy expenditure obtained by GEDAE-LaB and commercial software for both moderate and severe domains (P > 0.05). The ICC revealed that these estimates were highly reliable among the four investigators for both moderate and severe domains (all ICC ≥ 0.94). Conclusion These findings suggest that GEDAE-LaB is a free software easily comprehended by users minimally familiarized with adopted procedures for calculations of energetic profile using oxygen uptake and lactate accumulation during exercise. By providing availability of the software and its source code we hope to facilitate future related research. PMID:26727499
GEDAE-LaB: A Free Software to Calculate the Energy System Contributions during Exercise.
Bertuzzi, Rômulo; Melegati, Jorge; Bueno, Salomão; Ghiarone, Thaysa; Pasqua, Leonardo A; Gáspari, Arthur Fernandes; Lima-Silva, Adriano E; Goldman, Alfredo
2016-01-01
The aim of the current study is to describe the functionality of free software developed for energy system contributions and energy expenditure calculation during exercise, namely GEDAE-LaB. Eleven participants performed the following tests: 1) a maximal cycling incremental test to measure the ventilatory threshold and maximal oxygen uptake (V̇O2max); 2) a cycling workload constant test at moderate domain (90% ventilatory threshold); 3) a cycling workload constant test at severe domain (110% V̇O2max). Oxygen uptake and plasma lactate were measured during the tests. The contributions of the aerobic (AMET), anaerobic lactic (LAMET), and anaerobic alactic (ALMET) systems were calculated based on the oxygen uptake during exercise, the oxygen energy equivalents provided by lactate accumulation, and the fast component of excess post-exercise oxygen consumption, respectively. In order to assess the intra-investigator variation, four different investigators performed the analyses independently using GEDAE-LaB. A direct comparison with commercial software was also provided. All subjects completed 10 min of exercise at moderate domain, while the time to exhaustion at severe domain was 144 ± 65 s. The AMET, LAMET, and ALMET contributions during moderate domain were about 93, 2, and 5%, respectively. The AMET, LAMET, and ALMET contributions during severe domain were about 66, 21, and 13%, respectively. No statistical differences were found between the energy system contributions and energy expenditure obtained by GEDAE-LaB and commercial software for both moderate and severe domains (P > 0.05). The ICC revealed that these estimates were highly reliable among the four investigators for both moderate and severe domains (all ICC ≥ 0.94). These findings suggest that GEDAE-LaB is a free software easily comprehended by users minimally familiarized with adopted procedures for calculations of energetic profile using oxygen uptake and lactate accumulation during exercise. By providing availability of the software and its source code we hope to facilitate future related research.
Brutsaert, Tom D; Parra, Esteban J; Shriver, Mark D; Gamboa, Alfredo; Palacios, Jose-Antonio; Rivera, Maria; Rodriguez, Ivette; León-Velarde, Fabiola
2003-08-01
Quechua in the Andes may be genetically adapted to altitude and able to resist decrements in maximal O2 consumption in hypoxia (DeltaVo2 max). This hypothesis was tested via repeated measures of Vo2 max (sea level vs. 4338 m) in 30 men of mixed Spanish and Quechua origins. Individual genetic admixture level (%Spanish ancestry) was estimated by using ancestry-informative DNA markers. Genetic admixture explained a significant proportion of the variability in DeltaVo2 max after control for covariate effects, including sea level Vo2 max and the decrement in arterial O2 saturation measured at Vo2 max (DeltaSpO2 max) (R2 for admixture and covariate effects approximately 0.80). The genetic effect reflected a main effect of admixture on DeltaVo2 max (P = 0.041) and an interaction between admixture and DeltaSpO2 max (P = 0.018). Admixture predicted DeltaVo2 max only in subjects with a large DeltaSpO2 max (P = 0.031). In such subjects, DeltaVo2 max was 12-18% larger in a subgroup of subjects with high vs. low Spanish ancestry, with least squares mean values (+/-SE) of 739 +/- 71 vs. 606 +/- 68 ml/min, respectively. A trend for interaction (P = 0.095) was also noted between admixture and the decrease in ventilatory threshold at 4338 m. As previously, admixture predicted DeltaVo2 max only in subjects with a large decrease in ventilatory threshold. These findings suggest that the genetic effect on DeltaVo2 max depends on a subject's aerobic fitness. Genetic effects may be more important (or easier to detect) in athletic subjects who are more likely to show gas-exchange impairment during exercise. The results of this study are consistent with the evolutionary hypothesis and point to a better gas-exchange system in Quechua.
Testosterone Conversion Blockade Increases Breathing Stability in Healthy Men during NREM Sleep
Chowdhuri, Susmita; Bascom, Amy; Mohan, David; Diamond, Michael P.; Badr, M. Safwan
2013-01-01
Study Objectives: Gender differences in the prevalence of sleep apnea/hypopnea syndrome may be mediated via male sex hormones. Our objective was to determine the exact pathway for a testosterone-mediated increased propensity for central sleep apnea via blockade of the 5α-reductase pathway of testosterone conversion by finasteride. Design: Randomization to oral finasteride vs. sham, single-center study. Setting: Sleep research laboratory. Participants: Fourteen healthy young males without sleep apnea Intervention: Hypocapnia was induced via brief nasal noninvasive positive pressure ventilation during stable NREM sleep. Cessation of mechanical ventilation resulted in hypocapnic central apnea or hypopnea. Measurements and Results: The apnea threshold (AT) was defined as the end-tidal CO2 (PETCO2) that demarcated the central apnea closest to the eupneic PETCO2. The CO2 reserve was defined as the difference in PETCO2 between eupnea and AT. The apneic threshold and CO2 reserve were measured at baseline and repeated after at a minimum of 1 month. Administration of finasteride resulted in decreased serum dihydrotestosterone. In the finasteride group, the eupneic ventilatory parameters were unchanged; however, the AT was decreased (38.9 ± 0.6 mm Hg vs.37.7 ± 0.9 mm Hg, P = 0.02) and the CO2 reserve was increased (-2.5 ± 0.3 mm Hg vs. -3.8 ± 0.5 mm Hg, P = 0.003) at follow-up, with a significantly lower hypocapnic ventilatory response, thus indicating increased breathing stability during sleep. No significant changes were noted in the sham group on follow-up study. Conclusions: Inhibition of testosterone action via the 5α-reductase pathway may be effective in alleviating breathing instability during sleep, presenting an opportunity for novel therapy for central sleep apnea in selected populations. Citation: Chowdhuri S; Bascom A; Mohan D; Diamond MP; Badr MS. Testosterone conversion blockade increases breathing stability in healthy men during NREM sleep. SLEEP 2013;36(12):1793-1798. PMID:24293753
VTGRAPH - GRAPHIC SOFTWARE TOOL FOR VT TERMINALS
NASA Technical Reports Server (NTRS)
Wang, C.
1994-01-01
VTGRAPH is a graphics software tool for DEC/VT or VT compatible terminals which are widely used by government and industry. It is a FORTRAN or C-language callable library designed to allow the user to deal with many computer environments which use VT terminals for window management and graphic systems. It also provides a PLOT10-like package plus color or shade capability for VT240, VT241, and VT300 terminals. The program is transportable to many different computers which use VT terminals. With this graphics package, the user can easily design more friendly user interface programs and design PLOT10 programs on VT terminals with different computer systems. VTGRAPH was developed using the ReGis Graphics set which provides a full range of graphics capabilities. The basic VTGRAPH capabilities are as follows: window management, PLOT10 compatible drawing, generic program routines for two and three dimensional plotting, and color graphics or shaded graphics capability. The program was developed in VAX FORTRAN in 1988. VTGRAPH requires a ReGis graphics set terminal and a FORTRAN compiler. The program has been run on a DEC MicroVAX 3600 series computer operating under VMS 5.0, and has a virtual memory requirement of 5KB.
Gandevia, Bryan
1963-01-01
Complaints of respiratory symptoms amongst workers in a factory using isocyanate to produce polyurethane foam led to a study of changes in ventilatory capacity in the course of several working days. Mean decreases of the order of 0·181. were observed in the forced expiratory volume at one second in 15 employees during each of three normal working shifts. No significant change occurred on days when a process involving the liberation of isocyanate was stopped, or when the men were given an oral aminophylline compound prophylactically. An aerosol of isoprenaline failed to reverse the decrease in ventilatory capacity observed during one normal working day. Approximately half the subjects studied were found to show increased bronchial sensitivity to a histamine aerosol; all were smokers, whereas none of the non-smokers showed a significant (over 10%) reduction in ventilatory capacity after histamine. Smokers and/or positive histamine reactors tended to show a greater decrease in ventilatory capacity during a working day than non-smokers or non-reactors. The present findings, which confirm clinical reports of adverse respiratory effects of isocyanate in low concentrations, are compared with other studies of ventilatory capacity during occupational exposure to respiratory irritants. PMID:14046157
Fu, Zhenxing; Powell, Frank L.
2011-01-01
During ventilatory acclimatization to hypoxia (VAH), time-dependent increases in ventilation lower Pco2 levels, and this persists on return to normoxia. We hypothesized that plasticity in the caudal nucleus tractus solitarii (NTS) contributes to VAH, as the NTS receives the first synapse from the carotid body chemoreceptor afferents and also contains CO2-sensitive neurons. We lesioned cells in the caudal NTS containing the neurokinin-1 receptor by microinjecting the neurotoxin saporin conjugated to substance P and measured ventilatory responses in awake, unrestrained rats 18 days later. Lesions did not affect hypoxic or hypercapnic ventilatory responses in normoxic control rats, in contrast to published reports for similar lesions in other central chemosensitive areas. Also, lesions did not affect the hypercapnic ventilatory response in chronically hypoxic rats (inspired Po2 = 90 Torr for 7 days). These results suggest functional differences between central chemoreceptor sites. However, lesions significantly increased ventilation in normoxia or acute hypoxia in chronically hypoxic rats. Hence, chronic hypoxia increases an inhibitory effect of neurokinin-1 receptor neurons in the NTS on ventilatory drive, indicating that these neurons contribute to plasticity during chronic hypoxia, although such plasticity does not explain VAH. PMID:21593425
al Makdessi, S; Sweidan, H; Dietz, K; Jacob, R
1999-04-01
The protective effect against reperfusion arrhythmias of a 3-month oral pretreatment with a dried extract of Crataegus oxyacantha (LI 132)(standardized to 2.2% flavonoids) was studied with the Langendorff heart of the rat after global no-flow ischemia. The heart was perfused with a modified Krebs-Henseleit solution in which the K+ content was reduced to 3.4 mmol/l in order to lower the fibrillation threshold. According to pilot experiments which considered various durations of global no-flow ischemia ranging from 10 to 20 minutes, two durations were chosen for the present study: 20 minutes (group 20) in which ventricular fibrillation (VF) was the predominant form of arrhythmias, and 18 minutes (group 18) in which the prevalence of VF was markedly lower despite the small difference in the duration of ischemia. Crataegus pretreatment significantly (p = 0.02) reduced the average prevalence of malignant arrhythmias (VF + Flutter) as observed during the 20-min-period of reperfusion as follows: group 20: from 89% (control, n = 9) to 51% (LI 132, n = 7), group 18: from 48% (control, n = 8) to 8% (LI 132, n = 8). In group 20, ventricular tachycardia (VT) could be observed only in the treated group, because of the predominance of VF in the control group. LI 132 pretreatment reduced the average prevalence of VT in group 18 in spite of the identical percentage of occurrence (6 out of 8 rats, with and without treatment) due to a shorter duration of the VT episodes. Thus, under the conditions of our experiments, effective prevention against reperfusion arrhythmias by Crataegus pretreatment was evident.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dale, R.; Sáez, D., E-mail: rdale@umh.es, E-mail: diego.saez@uv.es
The vector-tensor (VT) theory of gravitation revisited in this article was studied in previous papers, where it was proved that VT works and deserves attention. New observational data and numerical codes have motivated further development which is presented here. New research has been planed with the essential aim of proving that current cosmological observations, including Planck data, baryon acoustic oscillations (BAO), and so on, may be explained with VT, a theory which accounts for a kind of dark energy which has the same equation of state as vacuum. New versions of the codes CAMB and COSMOMC have been designed formore » applications to VT, and the resulting versions have been used to get the cosmological parameters of the VT model at suitable confidence levels. The parameters to be estimated are the same as in general relativity (GR), plus a new parameter D . For D = 0, VT linear cosmological perturbations reduces to those of GR, but the VT background may explain dark energy. The fits between observations and VT predictions lead to non vanishing | D | upper limits at the 1σ confidence level. The value D = 0 is admissible at this level, but this value is not that of the best fit in any case. Results strongly suggest that VT may explain current observations, at least, as well as GR; with the advantage that, as it is proved in this paper, VT has an additional parameter which facilitates adjustments to current observational data.« less
Acute severe asthma: performance of ventilator at simulated altitude.
Tourtier, Jean-Pierre; Forsans, Emma; Leclerc, Thomas; Libert, Nicolas; Ramsang, Solange; Tazarourte, Karim; Man, Michel; Borne, Marc
2011-04-01
Exacerbation of asthma can be seen during air transport. Severe patients, not responding to conventional therapy, require ventilator support. We evaluated the performance of two transport ventilators, built with turbine technology, the T-birdVSO2 and the LTV-1000, for use during aeromedical evacuation of acute severe asthma. We have assessed the ability of both the ventilators to deliver to an acute severe asthma model a tidal volume (Vt) set at different simulated altitudes, by changing the ambient air pressure. The simulated cabin altitudes were 1500, 2500, and 3000 m (decompression chamber). Vt was set at 700 and 400 ml in an acute severe asthma lung model. Comparisons of the preset with the actual measured values were accomplished using a t-test. Comparisons between the actual delivered Vt and set Vt showed a significant difference starting at 1500 m for both the ventilators. The T-birdVSO2 showed a decrease in the volume delivered, with a negative variation of more than 10% compared with the Vt set. The LTV-1000 showed mostly an increase in the volume delivered. The delivered Vt remained within 10% of the set Vt. The accuracy of Vt delivery was superior with the LTV-1000 than with the T-birdVSO2, but the higher delivered Vt of the LTV-1000 are likely to be more harmful than lower delivered Vt of the T-birdVSO2.
Samore, Naseer Ahmed; Imran Majeed, Syed Muhammad; Kayani, Azhar Mahmud; Bhalli, Muhammad Asif; Shabbir, Muhammad
2009-09-01
To determine the outcome of Radiofrequency Catheter Ablation (RFCA) as a non-pharmacological curative therapy for idiopathic Ventricular Tachycardia (VT) and to identify procedure-related complications. Descriptive study. The Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi, from February 2001 to October 2008. Ninety eight consecutive patients with idiopathic VT, resistant to drug therapy, who underwent Electrophysiology Studies (EPS) radiofrequency catheter ablation were enrolled. Clinical and electrophysiological variables were recorded and a descriptive analysis was done. Out of the 98 patients, 79 were males (80.6%). The mean age was 33.29+11.93 years. Modes of presentation were sustained VT, Repetitive Monomorphic VT (RMVT), Non-sustained VT (NSVT) and Ventricular Premature Beats (VPBs). Right Ventricular Outflow Tract (RVOT) VT was found in 37 patients, 37 had Idiopathic Left Ventricular Tachycardia (ILVT), 20 had Left Ventricular Outflow Tract (LVOT) VT, and Inflow Right Ventricular Tachycardia (IRVT) was found in 7 patients. Other sites of origin of VT were infrequent. Eight patients had dual morphologies of VT. Atrioventricular Nodal Re-entry Tachycardia (AVNRT) was found in 8 patients. RFCA was successful in abolishing inducible VT in 88 patients. One patient developed complete AV block requiring a permanent pacemaker. Results of this study confirm a high degree of success and safety of radiofrequency catheter ablation as curative therapy for idiopathic ventricular tachycardia.
Maia, Lígia de A; Samary, Cynthia S; Oliveira, Milena V; Santos, Cintia L; Huhle, Robert; Capelozzi, Vera L; Morales, Marcelo M; Schultz, Marcus J; Abreu, Marcelo G; Pelosi, Paolo; Silva, Pedro L; Rocco, Patricia Rieken Macedo
2017-10-01
Intraoperative mechanical ventilation may yield lung injury. To date, there is no consensus regarding the best ventilator strategy for abdominal surgery. We aimed to investigate the impact of the mechanical ventilation strategies used in 2 recent trials (Intraoperative Protective Ventilation [IMPROVE] trial and Protective Ventilation using High versus Low PEEP [PROVHILO] trial) on driving pressure (ΔPRS), mechanical power, and lung damage in a model of open abdominal surgery. Thirty-five Wistar rats were used, of which 28 were anesthetized, and a laparotomy was performed with standardized bowel manipulation. Postoperatively, animals (n = 7/group) were randomly assigned to 4 hours of ventilation with: (1) tidal volume (VT) = 7 mL/kg and positive end-expiratory pressure (PEEP) = 1 cm H2O without recruitment maneuvers (RMs) (low VT/low PEEP/RM-), mimicking the low-VT/low-PEEP strategy of PROVHILO; (2) VT = 7 mL/kg and PEEP = 3 cm H2O with RMs before laparotomy and hourly thereafter (low VT/moderate PEEP/4 RM+), mimicking the protective ventilation strategy of IMPROVE; (3) VT = 7 mL/kg and PEEP = 6 cm H2O with RMs only before laparotomy (low VT/high PEEP/1 RM+), mimicking the strategy used after intubation and before extubation in PROVHILO; or (4) VT = 14 mL/kg and PEEP = 1 cm H2O without RMs (high VT/low PEEP/RM-), mimicking conventional ventilation used in IMPROVE. Seven rats were not tracheotomized, operated, or mechanically ventilated, and constituted the healthy nonoperated and nonventilated controls. Low VT/moderate PEEP/4 RM+ and low VT/high PEEP/1 RM+, compared to low VT/low PEEP/RM- and high VT/low PEEP/RM-, resulted in lower ΔPRS (7.1 ± 0.8 and 10.2 ± 2.1 cm H2O vs 13.9 ± 0.9 and 16.9 ± 0.8 cm H2O, respectively; P< .001) and less mechanical power (63 ± 7 and 79 ± 20 J/min vs 110 ± 10 and 120 ± 20 J/min, respectively; P = .007). Low VT/high PEEP/1 RM+ was associated with less alveolar collapse than low VT/low PEEP/RM- (P = .03). E-cadherin expression was higher in low VT/moderate PEEP/4 RM+ than in low VT/low PEEP/RM- (P = .013) or high VT/low PEEP/RM- (P = .014). The extent of alveolar collapse, E-cadherin expression, and tumor necrosis factor-alpha correlated with ΔPRS (r = 0.54 [P = .02], r = -0.48 [P = .05], and r = 0.59 [P = .09], respectively) and mechanical power (r = 0.57 [P = .02], r = -0.54 [P = .02], and r = 0.48 [P = .04], respectively). In this model of open abdominal surgery based on the mechanical ventilation strategies used in IMPROVE and PROVHILO trials, lower mechanical power and its surrogate ΔPRS were associated with reduced lung damage.
Sudden cardiac arrest in people with epilepsy in the community
Lamberts, Robert J.; Blom, Marieke T.; Wassenaar, Merel; Bardai, Abdennasser; Leijten, Frans S.; de Haan, Gerrit-Jan; Sander, Josemir W.; Thijs, Roland D.
2015-01-01
Objective: To ascertain whether characteristics of ventricular tachycardia/fibrillation (VT/VF) differed between people with epilepsy and those without and which individuals with epilepsy were at highest risk. Methods: We ascertained 18 people with active epilepsy identified in a community-based registry of sudden cardiac arrest (SCA) with ECG-confirmed VT/VF (cases). We compared them with 470 individuals with VT/VF without epilepsy (VT/VF controls) and 54 individuals with epilepsy without VT/VF (epilepsy controls). Data on comorbidity, epilepsy severity, and medication use were collected and entered into (conditional) logistic regression models to identify determinants of VT/VF in epilepsy. Results: In most cases, there was an obvious (10/18) or presumed cardiovascular cause (5/18) in view of preexisting heart disease. In 2 of the 3 remaining events, near–sudden unexpected death in epilepsy (SUDEP) was established after successful resuscitation. Cases had a higher prevalence of congenital/inherited heart disease (17% vs 1%, p = 0.002), and experienced VT/VF at younger age (57 vs 64 years, p = 0.023) than VT/VF controls. VT/VF in cases occurred more frequently at/near home (89% vs 58%, p = 0.009), and was less frequently witnessed (72% vs 89%, p = 0.048) than in VT/VF controls. Cases more frequently had clinically relevant heart disease (50% vs 15%, p = 0.005) and intellectual disability (28% vs 1%, p < 0.001) than epilepsy controls. Conclusion: Cardiovascular disease rather than epilepsy characteristics is the main determinant of VT/VF in people with epilepsy in the community. SCA and SUDEP are partially overlapping disease entities. PMID:26092917
Duennwald, Tobias; Bernardi, Luciano; Gordin, Daniel; Sandelin, Anna; Syreeni, Anna; Fogarty, Christopher; Kytö, Janne P.; Gatterer, Hannes; Lehto, Markku; Hörkkö, Sohvi; Forsblom, Carol; Burtscher, Martin; Groop, Per-Henrik
2013-01-01
Hypoxemia is common in diabetes, and reflex responses to hypoxia are blunted. These abnormalities could lead to cardiovascular/renal complications. Interval hypoxia (IH) (5–6 short periods of hypoxia each day over 1–3 weeks) was successfully used to improve the adaptation to hypoxia in patients with chronic obstructive pulmonary disease. We tested whether IH over 1 day could initiate a long-lasting response potentially leading to better adaptation to hypoxia. In 15 patients with type 1 diabetes, we measured hypoxic and hypercapnic ventilatory responses (HCVRs), ventilatory recruitment threshold (VRT-CO2), baroreflex sensitivity (BRS), blood pressure, and blood lactate before and after 0, 3, and 6 h of a 1-h single bout of IH. All measurements were repeated on a placebo day (single-blind protocol, randomized sequence). After IH (immediately and after 3 h), hypoxic and HCVR increased, whereas the VRT-CO2 dropped. No such changes were observed on the placebo day. Systolic and diastolic blood pressure increased, whereas blood lactate decreased after IH. Despite exposure to hypoxia, BRS remained unchanged. Repeated exposures to hypoxia over 1 day induced an initial adaptation to hypoxia, with improvement in respiratory reflexes. Prolonging the exposure to IH (>2 weeks) in type 1 diabetic patients will be a matter for further studies. PMID:23733200
Feature Weighting via Optimal Thresholding for Video Analysis (Open Access)
2014-03-03
EKF MKL LPBoost ALF FWOT BP CaVT FMG GaVU GaA MaS PR PK RaA WaSP Mean 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 P m is s@ T E R = 1 2 .5 Trajectory EKF MKL...processing, and finance. SIAM Journal on Op- timization, 19(3):1344–1367, 2008. [8] H. Kuehne, H. Jhuang, E . Garrote, T. Poggio, and T. Serre. HMDB: a large...Vitaladevuni, X. Zhuang, S. Tsakalidis , U. Park, and R. Prasad. Multimodal feature fusion for robust event detection in web videos. In CVPR, 2012. [16] A
Factors affecting performance in an ultraendurance triathlon.
Laursen, P B; Rhodes, E C
2001-01-01
In the recent past, researchers have found many key physiological variables that correlate highly with endurance performance. These include maximal oxygen uptake (VO2max), anaerobic threshold (AT), economy of motion and the fractional utilisation of oxygen uptake (VO2). However, beyond typical endurance events such as the marathon, termed 'ultraendurance' (i.e. >4 hours), performance becomes harder to predict. The ultraendurance triathlon (UET) is a 3-sport event consisting of a 3.8 km swim and a 180 km cycle, followed by a 42.2 km marathon run. It has been hypothesised that these triathletes ride at approximately their ventilatory threshold (Tvent) during the UET cycling phase. However, laboratory assessments of cycling time to exhaustion at a subject's AT peak at 255 minutes. This suggests that the AT is too great an intensity to be maintained during a UET, and that other factors cause detriments in prolonged performance. Potential defeating factors include the provision of fuels and fluids due to finite gastric emptying rates causing changes in substrate utilisation, as well as fluid and electrolyte imbalances. Thus, an optimum ultraendurance intensity that may be relative to the AT intensity is needed to establish ultraendurance intensity guidelines. This optimal UET intensity could be referred to as the ultraendurance threshold.
Verocytotoxin-induced apoptosis of human microvascular endothelial cells.
Pijpers, A H; van Setten, P A; van den Heuvel, L P; Assmann, K J; Dijkman, H B; Pennings, A H; Monnens, L A; van Hinsbergh, V W
2001-04-01
The pathogenesis of the epidemic form of hemolytic uremic syndrome is characterized by endothelial cell damage. In this study, the role of apoptosis in verocytotoxin (VT)-mediated endothelial cell death in human glomerular microvascular endothelial cells (GMVEC), human umbilical vein endothelial cells, and foreskin microvascular endothelial cells (FMVEC) was investigated. VT induced apoptosis in GMVEC and human umbilical vein endothelial cells when the cells were prestimulated with the inflammatory mediator tumor necrosis factor-alpha (TNF-alpha). FMVEC displayed strong binding of VT and high susceptibility to VT under basal conditions, which made them suitable for the study of VT-induced apoptosis without TNF-alpha interference. On the basis of functional (flow cytometry and immunofluorescence microscopy using FITC-conjugated annexin V and propidium iodide), morphologic (transmission electron microscopy), and molecular (agarose gel electrophoresis of cellular DNA fragments) criteria, it was documented that VT induced programmed cell death in microvascular endothelial cells in a dose- and time-dependent manner. Furthermore, whereas partial inhibition of protein synthesis by VT was associated with a considerable number of apoptotic cells, comparable inhibition of protein synthesis by cycloheximide was not. This suggests that additional pathways, independent of protein synthesis inhibition, may be involved in VT-mediated apoptosis in microvascular endothelial cells. Specific inhibition of caspases by Ac-Asp-Glu-Val-Asp-CHO, but not by Ac-Tyr-Val-Ala-Asp-CHO, was accompanied by inhibition of VT-induced apoptosis in FMVEC and TNF-alpha-treated GMVEC. These data indicate that VT can induce apoptosis in human microvascular endothelial cells.
Giudici, Marcela; Pascual, Roberto; de la Canal, Laura; Pfüller, Karola; Pfüller, Uwe; Villalaín, José
2003-01-01
Viscotoxins are small proteins that are thought to interact with biomembranes, displaying different toxic activities against a varied number of cell types, being viscotoxin A3 (VtA3) the most cytotoxic whereas viscotoxin B (VtB) is the less potent. By using infrared and fluorescence spectroscopies, we have studied the interaction of VtA3 and VtB, both wild and reduced ones, with model membranes containing negatively charged phospholipids. Both VtA3 and VtB present a high conformational stability, and a similar conformation both in solution and when bound to membranes. In solution, the infrared spectra of the reduced proteins show an increase in bandwidth compared to the nonreduced ones indicating a greater flexibility. VtA3 and VtB bind with high affinity to membranes containing negatively charged phospholipids and are motional restricted, their binding being dependent on phospholipid composition. Whereas nonreduced proteins maintain their structure when bound to membranes, reduced ones aggregate. Furthermore, leakage experiments show that wild proteins were capable of disrupting membranes whereas reduced proteins were not. The effect of VtA3 and VtB on membranes having different phospholipid composition is diverse, affecting the cooperativity and fluidity of the membranes. Viscotoxins interact with membranes in a complex way, most likely organizing themselves at the surface inducing the appearance of defects that lead to the destabilization and disruption of the membrane bilayer. PMID:12885644
Luo, Bin; Zhou, Gongbu; Guo, Xiaogang; Liu, Xu; Yang, Jiandu; Sun, Qi; Ma, Jian; Zhang, Shu
2017-06-01
The present study aimed to retrospectively investigate long-term clinical outcomes of patients undergoing catheter ablation of left posterior fascicular ventricular tachycardia (LPF-VT) with the development of left posterior fascicular block (LPF block) and characteristics of repeat procedures. A total of 195 patients (mean age 29.76±1.03years, 16.4% females) who underwent catheter ablation for LPF-VT were consecutively enrolled. The earliest ventricular potential with a single fused Purkinje potential (PP) during VT and the PP located in the inferior-apical or mid-apical septum during SR were targeted for linear ablation. The endpoint of the procedure was noninducible VT and development of new-onset LPF block. Follow-up with clinic visits or telephonic interviews, electrocardiogram (ECG), or Holter monitoring was performed after the procedure. With a median follow-up of 85 (18,181) months, 20 patients were censored and 152 of 175 (86.86%) patients had long-term freedom from VT after a single procedure. No statistical difference in the outcome of catheter ablation of LPF-VT was found between inducible and non-inducible groups (P=0.89). Twenty-three patients exhibited recurrent LPF-VT. Seven of 23 patients developed new-onset left upper septal ventricular tachycardia that was successfully ablated. All the patients undergoing repeat procedures had freedom from VT. No procedural complications occurred. Ablation of LPF-VT using the development of LPF block as the endpoint is associated with a high procedural success rate. No difference in freedom from LPF-VT was found between inducible and non-inducible patients. New-onset LPF block recovery and non-early PP-QRS interval can be the predictors of LPF-VT repeat procedure. Copyright © 2017 Elsevier B.V. All rights reserved.
Hoekstra, W. J.; Schotzinger, R. J.; Sobel, J. D.; Lilly, E. A.; Fidel, P. L.
2015-01-01
Vulvovaginal candidiasis (VVC) and recurrent VVC (RVVC) remain major health problems for women. VT-1161, a novel fungal CYP51 inhibitor which has potent antifungal activity against fluconazole-sensitive Candida albicans, retained its in vitro potency (MIC50 of ≤0.015 and MIC90 of 0.12 μg/ml) against 10 clinical isolates from VVC or RVVC patients resistant to fluconazole (MIC50 of 8 and MIC90 of 64 μg/ml). VT-1161 pharmacokinetics in mice displayed a high volume of distribution (1.4 liters/kg), high oral absorption (73%), and a long half-life (>48 h) and showed rapid penetration into vaginal tissue. In a murine model of vaginal candidiasis using fluconazole-sensitive yeast, oral doses as low as 4 mg/kg VT-1161 significantly reduced the fungal burden 1 and 4 days posttreatment (P < 0.0001). Similar VT-1161 efficacy was measured when an isolate highly resistant to fluconazole (MIC of 64 μg/ml) but fully sensitive in vitro to VT-1161 was used. When an isolate partially sensitive to VT-1161 (MIC of 0.12 μg/ml) and moderately resistant to fluconazole (MIC of 8 μg/ml) was used, VT-1161 remained efficacious, whereas fluconazole was efficacious on day 1 but did not sustain efficacy 4 days posttreatment. Both agents were inactive in treating an infection with an isolate that demonstrated weaker potency (MICs of 2 and 64 μg/ml for VT-1161 and fluconazole, respectively). Finally, the plasma concentrations of free VT-1161 were predictive of efficacy when in excess of the in vitro MIC values. These data support the clinical development of VT-1161 as a potentially more efficacious treatment for VVC and RVVC. PMID:26124165
Škerk, Vedrana; Markotić, Alemka; Brkljačić, Diana Delić; Manola, Šime; Krčmar, Tomislav; Gabrić, Ivo Darko; Štajminger, Gordana; Pintarić, Hrvoje
2013-01-01
Background Ventricular tachycardia (VT) is frequently seen in ischemic settings like acute myocardial infarction with ST segment elevation (STEMI). Endothelial dysfunction (ED) represents inflammation and the loss of all protective features of the endothelium. We aimed to examine the association between VT and ED in patients with STEMI. Material/Methods The study included 90 subjects (30 with VT and acute STEMI, 30 with STEMI without VT, and 30 controls). Sera of all subjects were tested on ED markers by enzyme immunoassay: sICAM-1 (intracellular adhesive molecule-1), sVCAM-1 (vascular adhesive molecule-1), P- and E-selectins, and VEGF (vascular endothelial growth factor). In addition, CRP (C-reactive protein) was detected. Results Significantly increased values of low-density lipoprotein, triglycerides, leukocytes, creatinine, and the number of cigarettes smoked were observed among patients with VT+STEMI in comparison to controls. The levels of E-selectin were significantly lower in the VT+STEMI group than in the other groups, while the levels of VCAM-1 were significantly higher in the groups with STEMI and VT+STEMI compared to the controls. Lower levels of VEGF were recorded in STEMI and VT+STEMI groups compared to the control group. A significant correlation between CRP and VCAM-1 in patients with VT +STEMI was demonstrated. Conclusions We showed that ED may have a role in the immunopathogenesis of VT in patients with STEMI. The role of sE-selectin and correlation of sVCAM-1 with CRP as possible ED predictive markers in patients with VT+STEMI should be further investigated in a large cohort of patients. PMID:24253420
The Association of Statin Therapy with the Risk of Recurrent Venous Thrombosis
Smith, Nicholas L.; Harrington, Laura B.; Blondon, Marc; Wiggins, Kerri L.; Floyd, James S.; Sitlani, Colleen M.; McKnight, Barbara; Larson, Eric B.; Rosendaal, Frits R.; Heckbert, Susan R.; Psaty, Bruce M.
2016-01-01
Background Meta-analyses of randomized controlled trials suggest that treatment with HMG-CoA reductase inhibitors (statins) lowers the risk of incident venous thrombosis (VT), particularly among those without prevalent clinical cardiovascular disease (CVD). Whether this is true for the prevention of recurrent VT is debated. We used an observational inception cohort to estimate the association of current statin use with the risk of recurrent VT. Methods and Results The study setting was a large healthcare organization with detailed medical record and pharmacy information at cohort entry and throughout follow-up. We followed 2,798 subjects 18–89 years of age who experienced a validated incident VT between January 1, 2002 and December 31, 2010, for a first recurrent VT, validated by medical record review. During follow-up, 457 (16%) developed a first recurrent VT. In time-to-event models incorporating time-varying statin use and adjusting for potential confounders, current statin use was associated with a 26% lower risk of recurrent VT: HR=0.74; 95%CI: 0.59–0.94. Among cohort members free of CVD (n=2,134), current statin use was also associated with a lower risk (38%) of recurrent VT: HR=0.62; 95%CI: 0.45–0.85. We found similar results when restricting to new users of statins and in subgroups of different statin types and doses. Conclusions In a population-based cohort of subjects who had experienced an incident VT, statin use, compared with non-use, was associated with a clinically-relevant lower risk of recurrent VT. These findings suggest a potential secondary benefit of statins among patients who have experienced an incident VT. PMID:27061794
Lung and chest wall impedances in the dog: effects of frequency and tidal volume.
Barnas, G M; Stamenović, D; Lutchen, K R; Mackenzie, C F
1992-01-01
Dependences of the mechanical properties of the respiratory system on frequency (f) and tidal volume (VT) in the normal ranges of breathing are not clear. We measured, simultaneously and in vivo, resistance and elastance of the total respiratory system (Rrs and Ers), lungs (RL and EL), and chest wall (Rcw and Ecw) of five healthy anesthetized paralyzed dogs during sinusoidal volume oscillations at the trachea (50-300 ml, 0.2-2 Hz) delivered at a constant mean lung volume. Each dog showed the same f and VT dependences. The Ers and Ecw increased with increasing f to 1 Hz and decreased with increasing VT up to 200 ml. Although EL increased slightly with increasing f, it was independent of VT. The Rcw decreased from 0.2 to 2 Hz at all VT and decreased with increasing VT. Although the RL decreased from 0.2 to 0.6 Hz and was independent of VT, at higher f RL tended to increase with increasing f and VT (i.e., as peak flow increased). Finally, the f and VT dependences of Rrs were similar to those of Rcw below 0.6 Hz but mirrored RL at higher f. These data capture the competing influences of airflow nonlinearities vs. tissue nonlinearities on f and VT dependence of the lung, chest wall, and total respiratory system. More specifically, we conclude that 1) VT dependences in Ers and Rrs below 0.6 Hz are due to nonlinearities in chest wall properties, 2) above 0.6 Hz, the flow dependence of airways resistance dominates RL and Rrs, and 3) lung tissue behavior is linear in the normal range of breathing.
Volume versus wiring transmission in the brain: a new theoretical frame for neuropsychopharmacology.
Agnati, L F; Bjelke, B; Fuxe, K
1995-01-01
A volume transmission mode of communication in brain was implicit already in the early work of Golgi, who postulated the existence of electrical signals in the extracellular fluid (ECF) based on Volta's "wet conductor" made by solutions. The term volume transmission is taken from the term volume conduction describing the flow of ionic currents in the ECF as a basis for the electrocorticogram. The slow VT mode includes also chemical signals and is opposed to the fast synaptic (wiring) transmission. Every neuron may function in a dual mode, the synaptic and the volume transmission mode, when considering the autocrine and synaptic classes of communication. The paracrine- and neuroendocrine-like classes only involve the VT mode in the latter case including the CSF as a route. The chemical signals for VT are the neuropeptides, but also the classical transmitters, the monoamines, acetylcholine, GABA, and glutamate can participate, when they operate via slow, high affinity G protein coupled receptors. Ions such as K+, Ca++, and H+ also function as VT signals. The hypothesis is also introduced that CO2 can act as a multifacit long-distance VT and WT regulator besides being part of the CO2/HCO3 buffer. CO2 via regulating NMDA receptor sensitivity can also regulate NO formation, which represents a paracrine and fast VT signal. The therapy of CNS disorders is also discussed in the frame of the wiring and VT concept. Two therapeutical approaches can therefore be developed, one based on increasing WT and one based on increasing VT. In contrast to the WT therapy, which must preserve the electrotemporal code, the VT therapy can operate also with postsynaptic agonists. Therefore, a therapeutic effect with such a drug indicates that the deficiency in the communication process operates via VT. In view of the lack of very effective negative feedbacks in VT vs. WT, VT therapy may produce less tolerance and drug dependency.
Predictors of new malignant ventricular arrhythmias after coronary surgery: a case-control study.
Ascione, Raimondo; Reeves, Barnaby C; Santo, Kirkpatrick; Khan, Nouman; Angelini, Gianni D
2004-05-05
We sought to investigate the relationship between perioperative factors and the occurrence of ventricular tachycardia (VT) and ventricular fibrillation (VF), as well as the impact of VT/VF on early and late mortality. Both VT and VF are rare but serious complications after coronary artery bypass graft surgery (CABG), and their etiology and implications remain uncertain. Data on 4,411 consecutive patients undergoing CABG (1,154 [25.8%] had off-pump surgery) between April 1996 and September 2001 were extracted from a prospective database and analyzed. Odds ratios (ORs) describing associations between possible risk factors and VT/VF were estimated separately. Factors observed to be significantly associated with VT/VF were further investigated using multivariate logistic regression. Sixty-nine patients suffered VT/VF (1.6%). There were 61 (1.4%) in-hospital/30-day deaths, 15 among patients who had postoperative VT/VF (21.7%). Patient factors independently associated with an increase in the odds of VT/VF included age <65 years, female gender, body mass index <25 kg/m(2), unstable angina, moderate or poor ejection fraction, and the need for inotropes and an intra-aortic balloon pump (OR 1.72 to 4.47, p < 0.05). After adjustment, off-pump surgery was associated with a substantial but nonsignificant protective effect against VT/VF (OR 0.53, 95% confidence interval [CI] 0.25 to 1.13; p = 0.10). Actuarial survival at two years was 98.2% among patients who had VT/VF and who survived to discharge/30 days, compared with 97.0% for the control group (adjusted hazard ratio 0.96 (95% CI 0.40 to 2.31, p = 0.92). The incidence of VT/VF is low in patients undergoing coronary surgery but is associated with high in-hospital mortality. The late survival of the discharged VT/VF patients compares favorably with that of controls.
Delécrin, Joël; Allain, Jérôme; Beaurain, Jacques; Steib, Jean-Paul; Chataigner, Hervé; Aubourg, Lucie; Huppert, Jean; Ameil, Marc; Nguyen, Jean-Michel
2009-01-01
Background An artificial disc prosthesis is thought to restore segmental motion in the lumbar spine. However, it is reported that disc prosthesis can increase the intervertebral translation (VT). The concept of the mobile-core prosthesis is to mimic the kinematic effects of the migration of the natural nucleus and therefore core mobility should minimize the VT. This study explored the hypothesis that core translation should influence VT and that a mobile core prosthesis may facilitate physiological motion. Methods Vertebral translation (measured with a new method presented here), core translation, range of motion (ROM), and distribution of flexion-extension were measured on flexion-extension, neutral standing, and lateral bending films in 89 patients (63 mobile-core [M]; 33 fixed-core [F]). Results At L4-5 levels the VT with M was lower than with F and similar to the VT of untreated levels. At L5-S1 levels the VT with M was lower than with F but was significantly different compared to untreated levels. At M levels a strong correlation was found between VT and core translation; the VT decreases as the core translation increases. At F levels the VT increases as the ROM increases. No significant difference was found between the ROM of untreated levels and levels implanted with either M or F. Regarding the mobility distribution with M and F we observed a deficit in extension at L5-S1 levels and a similar distribution at L4-5 levels compared to untreated levels. Conclusion The intervertebral mobility was different between M and F. The M at L4-5 levels succeeded to replicate mobility similar to L4-5 untreated levels. The M at L5-S1 succeeded in ROM, but failed regarding VT and mobility distribution. Nevertheless M minimized VT at L5-S1 levels. The F increased VT at both L4-5 and L5-S1. Clinical Relevance This study validates the concept that the core translation of an artificial lumbar disc prosthesis minimizes the VT. PMID:25802632
Sustained microgravity reduces the human ventilatory response to hypoxia but not to hypercapnia.
Prisk, G K; Elliott, A R; West, J B
2000-04-01
We measured the isocapnic hypoxic ventilatory response and the hypercapnic ventilatory response by using rebreathing techniques in five normal subjects (ages 37-47 yr) before, during, and after 16 days of exposure to microgravity (microG). Control measurements were performed with the subjects in the standing and supine postures. In both microG and in the supine position, the hypoxic ventilatory response, as measured from the slope of ventilation against arterial O(2) saturation, was greatly reduced, being only 46 +/- 10% (microG) and 52 +/- 11% (supine) of that measured standing (P < 0.01). During the hypercapnic ventilatory response test, the ventilation at a PCO(2) of 60 Torr was not significantly different in microG (101 +/- 5%) and the supine position (89 +/- 3%) from that measured standing. Inspiratory occlusion pressures agreed with these results. The findings can be explained by inhibition of the hypoxic but not hypercapnic drive, possibly as a result of an increase in blood pressure in carotid baroreceptors in microG and the supine position.
The influence of chronic hypoxia upon chemoreception
Powell, Frank L.
2007-01-01
Carotid body chemoreceptors are essential for time-dependent changes in ventilatory control during chronic hypoxia. Early theories of ventilatory acclimatization to hypoxia focused on time-dependent changes in known ventilatory stimuli, such as small changes in arterial pH that may play a significant role in some species. However, plasticity in the cellular and molecular mechanisms of carotid body chemoreception play a major role in ventilatory acclimatization to hypoxia in all species studied. Chronic hypoxia causes changes in (a) ion channels (potassium, sodium, calcium) to increase glomus cell excitability, and (b) neurotransmitters (dopamine, acetylcholine, ATP) and neuromodulators (endothelin-1) to increase carotid body afferent activity for a given PO2 and optimize O2-sensitivity. O2-sensing heme-containing molecules in the carotid body have not been studied in chronic hypoxia. Plasticity in medullary respiratory centers processing carotid body afferent input also contributes to ventilatory acclimatization to hypoxia. It is not known if the same mechanisms occur in patients with chronic hypoxemia from lung disease or high altitude natives. PMID:17291837
Ventilatory effects of substance P, vasoactive intestinal peptide, and nitroprusside in humans.
Maxwell, D L; Fuller, R W; Dixon, C M; Cuss, F M; Barnes, P J
1990-01-01
Animal studies suggest that the neuropeptides, substance P and vasoactive intestinal peptide (VIP), may influence carotid body chemoreceptor activity and that substance P may take part in the carotid body response to hypoxia. The effects of these peptides on resting ventilation and on ventilatory responses to hypoxia and to hypercapnia have been investigated in six normal humans. Infusions of substance P (1 pmol.kg-1.min-1) and of VIP (6 pmol.kg-1.min-1) were compared with placebo and with nitroprusside (5 micrograms.kg-1.min-1) as a control for the hypotensive action of the peptides. Both peptides caused significantly less hypotension than nitroprusside. Substance P and nitroprusside caused significantly greater increases in ventilation and in the hypoxic ventilatory response than VIP. No changes were seen in hypercapnic sensitivity. The stimulation of ventilation and the differential effects on ventilatory chemosensitivity that accompanied hypotension are consistent either with stimulation of carotid body chemoreceptor activity or with an interaction with peripheral chemoreceptor input to the respiratory center, as is seen in animals. The similar cardiovascular but different ventilatory effects of the peptides suggest that substance P may also stimulate the carotid body in a manner independent of the effect of hypotension. This is consistent with a role of substance P in the hypoxic ventilatory response in humans.
A historical perspective on ventilator management.
Shapiro, B A
1994-02-01
Paralysis via neuromuscular blockade in ICU patients requires mechanical ventilation. This review historically addresses the technological advances and scientific information upon which ventilatory management concepts are based, with special emphasis on the influence such concepts have had on the use of neuromuscular blocking agents. Specific reference is made to the scientific information and technological advances leading to the newer concepts of ventilatory management. Information from > 100 major studies in the peer-reviewed medical literature, along with the author's 25 yrs of clinical experience and academic involvement in acute respiratory care is presented. Nomenclature related to ventilatory management is specifically defined and consistently utilized to present and interpret the data. Pre-1970 ventilatory management is traced from the clinically unacceptable pressure-limited devices to the reliable performance of volume-limited ventilators. The scientific data and rationale that led to the concept of relatively large tidal volume delivery are reviewed in the light of today's concerns regarding alveolar overdistention, control-mode dyssynchrony, and auto-positive end-expiratory pressure. Also presented are the post-1970 scientific rationales for continuous positive airway pressure/positive end-expiratory pressure therapy, avoidance of alveolar hyperxia, and partial ventilatory support techniques (intermittent mandatory ventilation/synchronized intermittent mandatory ventilation). The development of pressure-support devices is discussed and the capability of pressure-control techniques is presented. The rationale for more recent concepts of total ventilatory support to avoid ventilator-induced lung injury is presented. The traditional techniques utilizing volume-preset ventilators with relatively large tidal volumes remain valid and desirable for the vast majority of patients requiring mechanical ventilation. Neuromuscular blockade is best avoided in these patients. However, adequate analgesia, amnesia, and sedation are required. For patients with severe lung disease, alveolar overdistention and hyperoxia should be avoided and may be best accomplished by total ventilatory support techniques, such as pressure control. Total ventilatory support requires neuromuscular blockade and may not provide eucapnic ventilation.
Sands, Scott A; Edwards, Bradley A; Terrill, Philip I; Taranto-Montemurro, Luigi; Azarbarzin, Ali; Marques, Melania; Hess, Lauren B; White, David P; Wellman, Andrew
2018-05-01
Therapies for obstructive sleep apnea (OSA) could be administered on the basis of a patient's own phenotypic causes ("traits") if a clinically applicable approach were available. Here we aimed to provide a means to quantify two key contributors to OSA-pharyngeal collapsibility and compensatory muscle responsiveness-that is applicable to diagnostic polysomnography. Based on physiological definitions, pharyngeal collapsibility determines the ventilation at normal (eupneic) ventilatory drive during sleep, and pharyngeal compensation determines the rise in ventilation accompanying a rising ventilatory drive. Thus, measuring ventilation and ventilatory drive (e.g., during spontaneous cyclic events) should reveal a patient's phenotypic traits without specialized intervention. We demonstrate this concept in patients with OSA (N = 29), using a novel automated noninvasive method to estimate ventilatory drive (polysomnographic method) and using "gold standard" ventilatory drive (intraesophageal diaphragm EMG) for comparison. Specialized physiological measurements using continuous positive airway pressure manipulation were employed for further comparison. The validity of nasal pressure as a ventilation surrogate was also tested (N = 11). Polysomnography-derived collapsibility and compensation estimates correlated favorably with those quantified using gold standard ventilatory drive (R = 0.83, P < 0.0001; and R = 0.76, P < 0.0001; respectively) and using continuous positive airway pressure manipulation (R = 0.67, P < 0.0001; and R = 0.64, P < 0.001; respectively). Polysomnographic estimates effectively stratified patients into high versus low subgroups (accuracy, 69-86% vs. ventilatory drive measures; P < 0.05). Traits were near-identical using nasal pressure versus pneumotach (N = 11, R ≥ 0.98, both traits; P < 0.001). Phenotypes of pharyngeal dysfunction in OSA are evident from spontaneous changes in ventilation and ventilatory drive during sleep, enabling noninvasive phenotyping in the clinic. Our approach may facilitate precision therapeutic interventions for OSA.
Ji, G E; Park, S Y; Wong, S S; Pestka, J J
1998-02-06
Characterization of how vomitoxin (VT) and other trichothecenes affect macrophage regulatory and effector function may contribute to improved understanding of mechanisms by which these mycotoxins impact the immune system. The RAW 264.7 murine cell line was used as a macrophage model to assess effects of the VT on proliferation and the production of nitric oxide (NO), hydrogen peroxide (H2O2) and cytokines. Using the MTT cleavage assay, VT at concentrations of 50 ng/ml or higher was found to significantly decrease proliferation and viability of RAW 264.7 cells without stimulation or with stimulation by lipopolysaccharide (LPS) or interferon (IFN)-gamma. In the absence of an activation agent, VT (25-250 ng/ml) had negligible effects on the production of NO, H2O2, and cytokines. Upon activation with LPS at concentrations of 10 to 100 ng/ml, VT at 25-100 ng/ml markedly enhanced production of H2O2 but was inhibitory at 250 ng/ml. VT enhancement of H2O2 production was observed as early as 12 h after LPS stimulation. When IFN-gamma was used as the stimulant, VT (25-250 ng/ml) delayed peak H2O2 production. VT (25-250 ng/ml) also markedly decreased NO production in cells activated with LPS or IFN-gamma. Interestingly, VT superinduced TNF-alpha and IL-6 production in LPS-stimulated cells and also elevated TNF-alpha in IFN-gamma stimulated cells. These results suggest that VT can selectively and concurrently upregulate or downregulate critical functions associated with activated macrophages.
Herholz, C; Straub, R; Gerber, V; Wampfler, B; Lüthi, S; Imhof, A; Moens, Y; Busato, A
2002-03-01
The pulmonary health of 66 horses was assessed by a clinical examination and simple supplementary diagnostic methods. Single breath diagrams for CO(2) (SBD-CO(2)) and derived lung function indices were used to determine pulmonary function. The clinical signs in different groups were related to the results of the lung function indices derived from the SBD-CO(2). In horses with moderate to severe chronic obstructive pulmonary disease (COPD), a significant relationship was found between the respiratory frequency and the ratio of Bohr's dead space to the tidal volume (VD(Bohr)/VT), and between the physiological dead space/tidal volume ratio (VD(phys)/VT) and the ratio of the alveolar dead space to the alveolar tidal volume (VD(alv)/VT(alv)), but no significant associations were found between the arterial oxygen tension (P(a)O(2)) and lung function indices derived from the SBD-CO(2). The occurrence of cough, the viscosity of tracheobronchial mucus and the amount of polynuclear neutrophils in tracheobronchial aspirates were significantly related to the expiratory tidal volume (VT), the total expired volume of CO(2) (VCO(2)), VD(Bohr)/VT, VD(phys)/VT and VD(alv)/VT(alv). We conclude that abnormal findings in these clinical parameters indicate a measurable ventilation and perfusion (V(A)/Q) mismatch which is reflected by increases in dead space, VD(Bohr)/VT and VD(phys)/VT as well as VD(alv)/VT(alv). Copyright 2002 Elsevier Science Ltd. All rights reserved.
Baseline differences in the HF-ACTION trial by sex.
Piña, Ileana L; Kokkinos, Peter; Kao, Andrew; Bittner, Vera; Saval, Matt; Clare, Bob; Goldberg, Lee; Johnson, Maryl; Swank, Ann; Ventura, Hector; Moe, Gordon; Fitz-Gerald, Meredith; Ellis, Stephen J; Vest, Marianne; Cooper, Lawton; Whellan, David
2009-10-01
In patients with heart failure (HF), assessment of functional capacity plays an important prognostic role. Both 6-minute walk and cardiopulmonary exercise testing have been used to determine physical function and to determine prognosis and even listing for transplantation. However, as in HF trials, the number of women reported has been small, and the cutoffs for transplantation have been representative of male populations and extrapolated to women. It is also well known that peak VO(2) as a determinant of fitness is inherently lower in women than in men and potentially much lower in the presence of HF. Values for a female population from which to draw for this important determination are lacking. The HF-ACTION trial randomized 2,331 patients (28% women) with New York Heart Association class II-IV HF due to systolic dysfunction to either a formal exercise program in addition to optimal medical therapy or to optimal medical therapy alone without any formal exercise training. To characterize differences between men and women in the interpretation of final cardiopulmonary exercise testing models, the interaction of individual covariates with sex was investigated in the models of (1) VE/VCO(2), (2) VO(2) at ventilatory threshold (VT), (3) distance on the 6-minute walk, and (4) peak VO(2). The women were younger than the men and more likely to have a nonischemic etiology and a higher ejection fraction. Dose of angiotensin converting enzyme inhibitor (ACEI) was lower in the women, on average. The lower ACEI dose may reflect the higher use of angiotensin II receptor blocker (ARB) in women. Both the peak VO(2) and the 6-minute walk distance were significantly lower in the women than in the men. Perhaps the most significant finding in this dataset of baseline characteristics is that the peak VO(2) for women was significantly lower than that for men with similar ventricular function and health status. Therefore, in a well-medicated, stable, class II-IV HF cohort of patients who are able to exercise, women have statistically significantly lower peak VO(2) and 6-minute walk distance than men with similar health status and ventricular function. These data should prompt careful thought when considering prognostic markers for women and listing for cardiac transplant.
Murata, Hiroshige; Miyauchi, Yasushi; Hayashi, Meiso; Iwasaki, Yu-Ki; Yodogawa, Kenji; Ueno, Akira; Hayashi, Hiroshi; Tsuboi, Ippei; Uetake, Shunsuke; Takahashi, Kenta; Yamamoto, Teppei; Maruyama, Mitsunori; Akutsu, Koichi; Yamamoto, Takeshi; Kobayashi, Yoshinori; Tanaka, Keiji; Atarashi, Hirotsugu; Katoh, Takao; Shimizu, Wataru
2015-01-01
Few reports are available on the characteristics of electrical storms of ventricular tachycardia (VT storm) refractory to intravenous (IV) amiodarone. IV-amiodarone was administered to 60 patients with ventricular tachyarrhythmia between 2007 and 2012. VT storms, defined as 3 or more episodes of VT within 24 h, occurred in 30 patients (68±12 years, 7 female), with 12 having ischemic and 18 non-ischemic heart disease. We compared the clinical and electrocardiographic characteristics of the patients with VT storms suppressed by IV-amiodarone (Effective group) to those of patients not affected by the treatment (Refractory group). IV-amiodarone could not control recurrence of VT in 9 patients (30%). The Refractory group comprised 5 patients with acute myocardial infarctions. Although there was no difference in the VT cycle length, the QRS duration of both the VT and premature ventricular contractions (PVCs) followed by VT was narrower in the Refractory group than in the Effective group (140±30 vs. 178±25 ms, P<0.01; 121±14 vs. 179±22 ms, P<0.01). In the Refractory group, additional administration of IV-mexiletine and/or Purkinje potential-guided catheter ablation was effective. IV-amiodarone-refractory VT exhibited a relatively narrow QRS tachycardia. The narrow triggering PVCs, suggesting a Purkinje fiber origin, may be treated by additional IV-mexiletine and endocardial catheter ablation.
Vantage Theory and Linguistic Relativity
ERIC Educational Resources Information Center
Allan, Keith
2010-01-01
Rob MacLaury's Vantage Theory, VT, models the way in which a cognizer constructs, recalls, uses, and modifies a category in terms of point of view or vantage. Alongside of VT, there is place for the kind of semantic specification found in the lexicon. VT2 [Allan, Keith, 2002. "Vantage theory, VT2, and number." "Language Sciences" 24(5-6), 679-703…
Mohsenifar, Z; Tashkin, D P; Levy, S E; Bjerke, R D; Clements, P J; Furst, D
1981-05-01
Wasted ventilation fraction (Vd/Vt) normally declines substantially during exercise in persons without lung disease. Failure of Vd/Vt to decrease during exercise has been reported to be one of the earliest abnormalities in patients with dyspnea caused by pulmonary vaso-occlusive disease, suggesting that measurement of Vd/Vt at rest and during exercise are useful in the diagnosis of pulmonary vascular disorders. We studied pulmonary hemodynamic and Vd/Vt responses to exercise in 11 patients in the supine position with suspected pulmonary vascular involvement caused by progressive systemic sclerosis, systemic lupus erythematosus, or recurrent pulmonary emboli, 10 of whom had dyspnea at rest and/or on exertion. In contrast to previous reports of no change or an increase in Vd/Vt during exercise in patients with pulmonary vascular disease, we found Vd/Vt to decrease significantly during exercise in 8 of 9 patients in whom mean pulmonary artery pressures were abnormally elevated at rest and/or during exercise. Our findings suggest that normal responses of Vd/Vt to exercise do not exclude hemodynamically significant pulmonary vaso-occlusive disease.
Pulse Thermal Processing for Low Thermal Budget Integration of IGZO Thin Film Transistors
Noh, Joo Hyon; Joshi, Pooran C.; Kuruganti, Teja; ...
2014-11-26
Pulse thermal processing (PTP) has been explored for low thermal budget integration of indium gallium zinc oxide (IGZO) thin film transistors (TFTs). The IGZO TFTs are exposed to a broadband (0.2-1.4 m) arc lamp radiation spectrum with 100 pulses of 1 msec pulse width. The impact of radiant exposure power on the TFT performance was analyzed in terms of the switching characteristics and bias stress reliability characteristics, respectively. The PTP treated IGZO TFTs with power density of 3.95 kW/cm 2 and 0.1 sec total irradiation time showed comparable switching properties, at significantly lower thermal budget, to furnace annealed IGZO TFT.more » The typical field effect mobility FE, threshold voltage VT, and sub-threshold gate swing S.S were calculated to be 7.8 cm 2/ V s, 8.1 V, and 0.22 V/ decade, respectively. The observed performance shows promise for low thermal budget TFT integration on flexible substrates exploiting the large-area, scalable PTP technology.« less
Pulse Thermal Processing for Low Thermal Budget Integration of IGZO Thin Film Transistors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noh, Joo Hyon; Joshi, Pooran C.; Kuruganti, Teja
Pulse thermal processing (PTP) has been explored for low thermal budget integration of indium gallium zinc oxide (IGZO) thin film transistors (TFTs). The IGZO TFTs are exposed to a broadband (0.2-1.4 m) arc lamp radiation spectrum with 100 pulses of 1 msec pulse width. The impact of radiant exposure power on the TFT performance was analyzed in terms of the switching characteristics and bias stress reliability characteristics, respectively. The PTP treated IGZO TFTs with power density of 3.95 kW/cm 2 and 0.1 sec total irradiation time showed comparable switching properties, at significantly lower thermal budget, to furnace annealed IGZO TFT.more » The typical field effect mobility FE, threshold voltage VT, and sub-threshold gate swing S.S were calculated to be 7.8 cm 2/ V s, 8.1 V, and 0.22 V/ decade, respectively. The observed performance shows promise for low thermal budget TFT integration on flexible substrates exploiting the large-area, scalable PTP technology.« less
Characterization of Thermal Refugia and Biogeochemical Hotspots at Sleepers River Watershed, VT
NASA Astrophysics Data System (ADS)
Hwang, K.; Chandler, D. G.; Kelleher, C.; Shanley, J. B.; Shaw, S. B.
2017-12-01
During low flow, changes in the extent of the channel network in headwater catchments depend on groundwater-surface water interactions, and dictate thermal and biogeochemical heterogeneities. Channel reaches with low temperature may act as refugia for valued species such as brook trout, and warmer reaches with high dissolved organic matter may act as biogeochemical hotspots. Prior studies have found uniform scaling of hydrologic and biogeochemical processes above certain spatial thresholds but sizable heterogeneities in these processes below the threshold. We utilize high resolution measurements of water quality parameters including stream temperature, conductivity and fluorescent dissolved organic matter (fDOM) at tributaries in two catchments of Sleepers River Watershed, Vermont to investigate seasonal and spatial variation of water quality and scaling of stream chemistry within the intensive study area and the larger Sleepers River Watershed. This study leverages findings from various small scale regional studies to identify differences in headwater channel reach behavior in a similar climate across some dissimilar geomorphic units, to inform the identification of thermal refugia and biogeochemical hotspots.
[Effect of airway humidification on lung injury induced by mechanical ventilation].
Song, Junjie; Jiang, Min; Qi, Guiyan; Xie, Yuying; Wang, Huaiquan; Tian, Yonggang; Qu, Jingdong; Zhang, Xiaoming; Li, Haibo
2014-12-01
To explore the effect of airway humidification on lung injury as a result of mechanical ventilation with different tidal volume (VT). Twenty-four male Japanese white rabbits were randomly divided into four groups: low VT with airway humidification group, high VT with airway humidification group, low VT and high VT group without humidification, with 6 rabbits in each group. Mechanical ventilation was started after intubation and lasted for 6 hours. Low VT denoted 8 mL/kg, while high VT was 16 mL/kg, fraction of inspired oxygen (FiO₂) denoted 0.40, positive end-expiratory pressure (PEEP) was 0. Temperature at Y piece of circuit in airway humidification groups was monitored and controlled at 40 centigrade. Arterial blood gas analysis, including pH value, arterial partial pressure of oxygen (PaO₂), arterial partial pressure of carbon dioxide (PaCO₂), lung mechanics indexes, including peak airway pressure (P(peak)) and airway resistance (Raw), and lung compliance was measured at 0, 2, 4, 6 hours of mechanical ventilation. The levels of tumor necrosis factor-α (TNF-α) and interleukin-8 (IL-8) in plasma and bronchoalveolar lavage fluid (BALF) were determined by enzyme linked immunosorbent assay (ELISA). The animals were sacrificed at the end of mechanical ventilation. The wet to dry (W/D) ratio of lung tissues was calculated. Histopathologic changes in the lung tissueies were observed with microscope, and lung injury score was calculated. Scanning and transmission electron microscopies were used to examine the integrity of the airway cilia and the tracheal epithelium. Compared with low V(T) group, pH value in high V(T) group was significantly increased, PaCO₂was significantly lowered, and no difference in PaO₂was found. P(peak), Raw, and lung compliance were significantly increased during mechanical ventilation. There were no significant differences in blood gas analysis and lung mechanics indexes between low V(T) with airway humidification group and low V(T) group. Compared with high V(T) group, PaCO₂in high V(T) with airway humidification group was significantly decreased, Ppeak raised obviously, and no difference in pH value, PaO₂, Raw and pulmonary compliance was found. Compared with low V(T) with airway humidification group, no difference in blood gas analysis (PaCO2, mmHg, 1 mmHg=0.133 kPa) was found, but Ppeak (cmH₂O, 1 cmH₂O=0.098 kPa), Raw (cmH₂O), and lung compliance (mL/cmH₂O) were increased significantly in high V(T) with airway humidification group (PaCO₂at 2 hours: 27.96 ± 4.64 vs. 36.08 ± 2.11, 4 hours: 28.62 ± 2.93 vs. 34.55 ± 5.50, 6 hours: 29.33 ± 2.14 vs. 35.01 ± 5.53; Ppeak at 0 hour: 14.34 ± 1.97 vs. 8.84 ± 1.32, 2 hours: 17.33 ± 0.52 vs. 11.17 ± 2.14, 4 hours: 17.83 ± 0.98 vs. 12.67 ± 2.06, 6 hours: 18.67 ± 1.22 vs. 13.50 ± 2.16; Raw at 0 hour: 37.36 ± 5.14 vs. 27.0 5 ± 2.93, 2 hours: 43.94 ± 6.58 vs. 31.95 ± 3.56, 4 hours: 48.04 ± 6.07 vs. 35.24 ± 3.50, 6 hours: 50.33 ± 6.34 vs. 36.66 ± 3.64; pulmonary compliance at 6 hours: 2.28 ± 0.18 vs. 1.86 ± 0.37, all P<0.05). The lung W/D ratio in high VT group was significantly higher than that of the low V(T) group (6.17 ± 2.14 vs. 3.50 ± 1.52, P<0.05). W/D in high V(T) with airway humidification group was higher than that of low V(T) with airway humidification group but without statistically significant difference (5.17 ± 2.14 vs. 3.00 ± 1.10, P>0.05). Microscopic observation showed that cilia were partially detached, adhered and sparse in low V(T) group, while cilia in high V(T) group showed serious detachment and lodging. Remaining cilia were sparse, with lodging, and cellular structure was damaged. Lung tissue pathological injury score in the high V(T) group was significantly higher than that of low V(T) group (6.17 ± 2.14 vs. 3.50 ± 1.52, P<0.05). Cilia density and cellularity were normal in low V(T) with airway humidification group, and no difference in lung tissue pathological injury score was found compared with low V(T) group (3.00 ± 1.10 vs. 3.50 ± 1.52, P>0.05). Cilia were severely detached, adhered and lodging, and cellularity were not obvious in high V(T) with airway humidification group, and lung tissue pathological injury score was elevated significantly than that of the low V(T) with airway humidification group but without statistically significant difference (5.17 ± 2.14 vs. 3.00 ± 1.10, P>0.05). TNF-α and IL-8 concentrations showed no change in plasma and BALF in all groups during ventilation, and no significant difference was found among the groups. Airway humidification can alleviate pathological lung injury, damage of cilia and cellular structure in trachea caused by mechanical ventilation with low and high V(T). High V(T) with humidification can result in serious pulmonary edema.
Muser, Daniele; Liang, Jackson J; Pathak, Rajeev K; Magnani, Silvia; Castro, Simon A; Hayashi, Tatsuya; Garcia, Fermin C; Supple, Gregory E; Riley, Michael P; Lin, David; Dixit, Sanjay; Zado, Erica S; Frankel, David S; Callans, David J; Marchlinski, Francis E; Santangeli, Pasquale
2017-07-01
The goal of this study was to determine the long-term outcomes of catheter ablation (CA) of electrical storm in patients with nonischemic dilated cardiomyopathy (NIDCM) compared with patients with ischemic cardiomyopathy (ICM). CA of ventricular tachycardia (VT) electrical storm has been shown to improve VT-free survival in patients with ICM. Data on the outcomes of CA of electrical storm in patients with NIDCM are insufficient. The study included 267 consecutive patients with NIDCM (n = 71; ejection fraction 32 ± 14%) and ICM (n = 196; ejection fraction 28 ± 12%). Endo-epicardial CA was performed in 59 (22%) patients. CA was guided by activation and entrainment mapping for tolerated VT and pacemapping/targeting of abnormal substrate for unmappable VT. After a median follow-up of 45 (25th to 75th percentile: 9 to 71) months and 1 (25th to 75th percentile: 1 to 8) procedures, 76 (29%) patients died, 25 (9%) underwent heart transplantation, 87 (33%) experienced VT recurrence, and 13 (5%) had recurrence of electrical storm. Overall VT-free survival was 54% at 60 months (48% in NIDCM and 54% in ICM; p = 0.128). Patients with VT recurrence experienced a median of 2 (1 to 10) VT episodes in the 5 (1 to 14) months after the procedure. Death/transplantation-free survival was 62% at 60 months (53% in NIDCM and 64% in ICM; p = 0.067). Persistent inducibility of any VT with cycle length ≥250 ms at programmed stimulation at the end of the procedure was the only independent predictor of VT recurrence. Low ejection fraction, New York Heart Association functional class, and VT recurrence over follow-up independently predicted death/transplantation. CA of electrical storm was similarly effective in patients with NIDCM compared with patients with ICM, with elimination of electrical storm in 95% of cases and achievement of complete VT control at long-term follow-up in most patients. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Galy, O; Hue, O; Boussana, A; Le Gallais, D; Prefaut, C
2002-04-01
The aim of this study was to determine the effects of a prior run on the cardiorespiratory responses measured during a subsequent cycle segment. Twelve duathletes underwent three successive laboratory trials at an interval of one week: 1) an incremental cycle test, 2) 20 min of running followed by 20 min of cycling (RC), and 3) 20 min of control cycling (C) at the same intensity as the cycling segment of RC. Ventilatory data were collected every minute using a breath-by-breath automated system. Blood samples were collected to measure venous blood lactate concentration, [La], at rest, after the running and cycling segments of RC and after C. The results showed that the C segment of RC had significantly higher VE, VE/VO2, f and HR than C alone and significantly lower VT (p < 0.05) than C alone. Moreover, steady state during C of RC was reached at the 2nd min for VO2, VE, VCO2, VE/VO2, VE/VCO2, and VdT; at the 4th min for R and HR, and at the 5th min for f. The C of RC induced a significant increase in [La] in comparison with C alone. We concluded that the first minute of cycling after running during an RC trial induced specific metabolic and cardiorespiratory responses.
Van Laethem, Christophe; Goethals, Marc; Verstreken, Sofie; Walravens, Maarten; Wellens, Francis; De Proft, Margot; Bartunek, Jozef; Vanderheyden, Marc
2007-09-01
Recently, a new linear measure of ventilatory response to exercise, the oxygen uptake efficiency slope (OUES), was proposed in the evaluation of heart failure patients. No data are available on the response of the OUES after orthotopic heart transplantation (HTx). Thirty patients who underwent HTx between 1999 and 2003 were included in the study. Data from maximal cardiopulmonary exercise test, resting pulmonary function and hemodynamic assessment were collected before the transplant at time of screening and 1 year after HTx. During the first year after HTx, OUES and normalized OUES for body weight (OUES/kg) increased significantly from 15.6 +/- 4.9 to 19.7 +/- 4.8 (p < 0.05). Changes in OUES/kg were significantly correlated with changes in peak VO2, VAT and peak VE, and inversely to changes in peak VD/VT, but not to changes in VE/VCO2 slope (all p < 0.05). Changes in OUES or OUES/kg did not correlate with any changes in measures of resting lung volumes or capacities and measures of central hemodynamic function after HTx. OUES improved significantly after HTx, but, similar to other exercise parameters, remained considerably impaired. The changes in OUES were highly correlated with the improvements in other exercise variables, but did not correlate with marked improvements in central hemodynamics or resting lung function.
Vibration therapy in patients with cerebral palsy: a systematic review
Ritzmann, Ramona; Stark, Christina; Krause, Anne
2018-01-01
The neurological disorder cerebral palsy (CP) is caused by unprogressive lesions of the immature brain and affects movement, posture, and the musculoskeletal system. Vibration therapy (VT) is increasingly used to reduce the signs and symptoms associated with this developmental disability. The purpose of this narrative review was systematically to appraise published research regarding acute and long-term effects of VT on functional, neuromuscular, and structural parameters. Systematic searches of three electronic databases identified 28 studies that fulfilled the inclusion criteria. Studies were analyzed to determine participant characteristics, VT-treatment protocols, effect on gross motor function (GMF), strength, gait, posture, mobility, spasticity, reflex excitability, muscle tone, mass, and bone strength within this population, and outcome measures used to evaluate effects. The results revealed that one acute session of VT reduces reflex excitability, spasticity, and coordination deficits. Subsequently, VT has a positive effect on the ability to move, manifested for GMF, strength, gait, and mobility in patients with CP. Effects persist up to 30 minutes after VT. Long-term effects of VT manifest as reduced muscle tone and spasticity occurring concomitantly with improved movement ability in regard to GMF, strength, gait, and mobility, as well as increased muscle mass and bone-mineral density. Posture control remained unaffected by VT. In conclusion, the acute and chronic application of VT as a nonpharmacological approach has the potential to ameliorate CP symptoms, achieving functional and structural adaptations associated with significant improvements in daily living. Even though further studies including adult populations validating the neuromuscular mechanisms underlying the aforementioned adaptations should be fostered, growing scientific evidence supports the effectiveness of VT in regard to supplementing conventional treatments (physiotherapy and drugs). Therefore, VT could reduce CP-associated physical disability and sensorimotor handicaps. Goals for patients and their caregivers referring to greater independence and improved safety may be achieved more easily and time efficiently.
Garvey, E P; Hoekstra, W J; Schotzinger, R J; Sobel, J D; Lilly, E A; Fidel, P L
2015-09-01
Vulvovaginal candidiasis (VVC) and recurrent VVC (RVVC) remain major health problems for women. VT-1161, a novel fungal CYP51 inhibitor which has potent antifungal activity against fluconazole-sensitive Candida albicans, retained its in vitro potency (MIC50 of ≤0.015 and MIC90 of 0.12 μg/ml) against 10 clinical isolates from VVC or RVVC patients resistant to fluconazole (MIC50 of 8 and MIC90 of 64 μg/ml). VT-1161 pharmacokinetics in mice displayed a high volume of distribution (1.4 liters/kg), high oral absorption (73%), and a long half-life (>48 h) and showed rapid penetration into vaginal tissue. In a murine model of vaginal candidiasis using fluconazole-sensitive yeast, oral doses as low as 4 mg/kg VT-1161 significantly reduced the fungal burden 1 and 4 days posttreatment (P < 0.0001). Similar VT-1161 efficacy was measured when an isolate highly resistant to fluconazole (MIC of 64 μg/ml) but fully sensitive in vitro to VT-1161 was used. When an isolate partially sensitive to VT-1161 (MIC of 0.12 μg/ml) and moderately resistant to fluconazole (MIC of 8 μg/ml) was used, VT-1161 remained efficacious, whereas fluconazole was efficacious on day 1 but did not sustain efficacy 4 days posttreatment. Both agents were inactive in treating an infection with an isolate that demonstrated weaker potency (MICs of 2 and 64 μg/ml for VT-1161 and fluconazole, respectively). Finally, the plasma concentrations of free VT-1161 were predictive of efficacy when in excess of the in vitro MIC values. These data support the clinical development of VT-1161 as a potentially more efficacious treatment for VVC and RVVC. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
2014-01-01
Background: To aid decision making for pneumococcal conjugate vaccine (PCV) use in infant national immunization programs, we summarized the indirect effects of PCV on clinical outcomes among nontargeted age groups. Methods: We systematically reviewed the English literature on infant PCV dosing schedules published from 1994 to 2010 (with ad hoc addition of 2011 articles) for outcomes on children >5 years of age and adults including vaccine-type nasopharyngeal carriage (VT-NP), vaccine-type invasive pneumococcal disease (VT-IPD) and syndromic pneumonia. Results: Of 12,980 citations reviewed, we identified 21 VT-IPD, 6 VT-NP and 9 pneumonia studies. Of these 36, 21 (58%) included 3 primary doses plus PCV or pneumococcal polysaccharide vaccine (PPV23) booster schedule (3+1 or 3+PPV23), 5 (14%) 3+0, 9 (25%) 2+1 and 1 (3%) 2+0. Most (95%) were PCV7 studies. Among observational VT-IPD studies, all schedules (2+1, 3+0 and 3+1) demonstrated reductions in incidence among young adult groups. Among syndromic pneumonia observational studies (2+1, 3+0 and 3+1), only 3+1 schedules showed significant indirect impact. Of 2 VT-NP controlled trials (3+0 and 3+1) and 3 VT-NP observational studies (2+1, 3+1 and 3+PPV23), 3+1 and 3+PPV23 schedules showed significant indirect effect. The 1 study to directly compare between schedules was a VT-NP study (2+0 vs. 2+1), which found no indirect effect on older siblings and parents of vaccinated children with either schedule. Conclusions: Indirect benefit of a 3+1 infant PCV dosing schedule has been demonstrated for VT-IPD, VT-NP and syndromic pneumonia; 2+1 and 3+0 schedules have demonstrated indirect effect only for VT-IPD. The choice of optimal infant PCV schedule is limited by data paucity on indirect effects, especially a lack of head-to-head studies and studies of PCV10 and PCV13. PMID:24336058
Seita, Tetsurou; Kuribayashi, Takashi; Honjo, Toshio; Yamamoto, Shizuo
2013-04-01
The efficacy of bovine immune colostral (colostral) antibodies against verotoxin (VT) 2, flagellum and somatic cells of Escherichia coli (E. coli) O157:H7 in mice was determined. Three major immunoglobulin (Ig) classes were isolated from the colostral antibody against VT2 by affinity chromatography and were used for estimation. Mice inoculated with VT2 were administered each Ig class from the colostral antibody, colostral antibody (colostral whey containing antibody) or serum antibody against VT2 at 1 hour after VT2 inoculation. All control mice (20/20) died after administration of sterilized saline instead of the colostral antibody. The survival rate was 93.3% (14/15) after administration of S-IgA or IgM antibody, or colostral antibody. Survival rates for IgG antibody and serum antibody administration were 80% (12/15) and 60% (9/15), respectively. Serum concentrations of VT2, which was absorbed from the small intestine in mice after administration of VT2 and colostral antibody, were measured by fluorescence enzyme immunoassay (FEIA). Serum concentrations of VT2 after administration of colostral antibody were lower than those after administration of sterilized saline. Mice inoculated with VT2-producing E. coli 157:H7 were administered anti-flagellum or anti-somatic colostral antibodies. Survival rates for E. coli O157:H7-infected mice administered the anti-flagellum and anti-somatic colostral antibodies were 52.4% (11/21) and 22.2% (4/18), respectively. Furthermore, survival rates increased to 89.5% (17/19) with combined administration of anti-flagellum and anti-VT2 colostral antibodies. These results suggest that colostral antibodies against VT2, flagellum and somatic cells are effective against E. coli O157:H7 infection. Copyright © 2012. Published by Elsevier B.V.
Grimm, W; Menz, V; Hoffmann, J; Maisch, B
1998-04-01
Unnecessary shocks by ICDs for rhythms other than sustained VT or VF have been described as the most frequent adverse event in ICD patients. To avoid unnecessary shocks for self-terminating arrhythmias, the third-generation Jewel PCD defibrillators 7202, 7219, and 7220 Plus use a specially designed VF confirmation algorithm after charge end. The purpose of this study was to determine the ability of this VF confirmation algorithm to recognize nonsustained VT, and to analyze the reasons for failure of the PCD device to abort shock therapy for nonsustained VT despite use of this VF confirmation algorithm. Analysis of stored electrograms of electrical events triggering high voltage capacitor charging in the programmed VF zone of the device showed 36 spontaneous episodes of nonsustained VT (227 +/- 21 beats/min) during 18 +/- 7 months follow-up in 15 patients who had a Jewel PCD implanted at our hospital. Intracardiac electrogram recordings and simultaneously retrieved marker channels demonstrated that the ICD shock was appropriately aborted according to the VF confirmation algorithm in 24 (67%) of 36 episodes of nonsustained VT. Twelve episodes (33%) of nonsustained VT, however, were followed by spontaneous ICD shock in 6 (40%) of the 15 study patients. The only reason for all 12 shocks for sustained VT was the inability of the device to recognize the absence of VT after charge end due to shortcomings of the VF confirmation algorithm: 11 of the 12 shocks for nonsustained VT were triggered by the occurrence of paced beats during the VF confirmation period and 1 shock for nonsustained VT was triggered by the occurrence of 2 premature beats after charge end. Thus, better VF confirmation algorithms need to be incorporated in future PCD devices to avoid unnecessary shocks for nonsustained VT.
Rhythms and outcomes of adult in-hospital cardiac arrest.
Meaney, Peter A; Nadkarni, Vinay M; Kern, Karl B; Indik, Julia H; Halperin, Henry R; Berg, Robert A
2010-01-01
To determine the relationship of electrocardiographic rhythm during cardiac arrest with survival outcomes. Prospective, observational study. Total of 411 hospitals in the National Registry of Cardiopulmonary Resuscitation. Total of 51,919 adult patients with pulseless cardiac arrests from April 1999 to July 2005. Registry data collected included first documented rhythm, patient demographics, pre-event data, event data, and survival and neurologic outcome data. Of 51,919 indexed cardiac arrests, first documented pulseless rhythm was ventricular tachycardia (VT) in 3810 (7%), ventricular fibrillation (VF) in 8718 (17%), pulseless electrical activity (PEA) in 19,262 (37%) and asystole 20,129 (39%). Subsequent VT/VF (that is, VT or VF occurring during resuscitation for PEA or asystole) occurred in 5154 (27%), with first documented rhythm of PEA and 4988 (25%) with asystole. Survival to hospital discharge rate was not different between those with first documented VF and VT (37% each, adjusted odds ratio [OR]) 1.08; 95% confidence interval [CI] 0.95-1.23). Survival to hospital discharge was slightly more likely after PEA than asystole (12% vs. 11%, adjusted OR 1.1; 95% CI 1.00-1.18), Survival to discharge was substantially more likely after first documented VT/VF than PEA/asystole (adjusted OR 1.68; 95% CI 1.55-1.82). Survival to discharge was also more likely after PEA/asystole without subsequent VT/VF compared with PEA/asystole with subsequent VT/VF (14% vs. 7% for PEA without vs. with subsequent VT/VF; 12% vs. 8% for asystole without vs. with subsequent VT/VF; adjusted OR 1.60; 95% CI, 1.44-1.80). Survival to hospital discharge was substantially more likely when the first documented rhythm was shockable rather than nonshockable, and slightly more likely after PEA than asystole. Survival to hospital discharge was less likely following PEA/asystole with subsequent VT/VF compared to PEA/asystole without subsequent VT/VF.
Ball, Rachel Emma; Oliver, Matthew Kenneth; Gill, Andrew Bruce
2016-07-01
Predator avoidance is fundamental for survival and it can be particularly challenging for prey animals if physical movement away from a predatory threat is restricted. Many sharks and rays begin life within an egg capsule that is attached to the sea bed. The vulnerability of this sedentary life stage is exacerbated in skates (Rajidae) as the compulsory ventilatory activity of embryos makes them conspicuous to potential predators. Embryos can reduce this risk by mediating ventilatory activity if they detect the presence of a predator using an acute electrosense. To determine how early in embryonic life predator elicited behavioral responses can occur, the reactions of three different age groups (1/3 developed, 2/3 developed, and near hatching) of embryonic thornback rays Raja clavata were tested using predator-type electric field stimuli. Egg capsules were exposed to continuous or intermittent stimuli in order to assess varying predator-type encounter scenarios on the ventilatory behavior of different developmental stages. All embryos reacted with a "freeze response" following initial electric field (E-field) exposure, ceasing ventilatory behavior in response to predator presence, demonstrating electroreceptive functionality for the first time at the earliest possible stage in ontogeny. This ability coincided with the onset of egg ventilatory behavior and may represent an effective means to enhance survival. A continuous application of stimuli over time revealed that embryos can adapt their behavior and resume normal activity, whereas when presented intermittently, the E-field resulted in a significant reduction in overall ventilatory activity across all ages. Recovery from stimuli was significantly quicker in older embryos, potentially indicative of the trade-off between avoiding predation and adequate respiration. © 2015 Wiley Periodicals, Inc. Develop Neurobiol 76: 721-729, 2016. © 2015 Wiley Periodicals, Inc.
Why do nonsurvivors from community-acquired pneumonia not receive ventilatory support?
Bauer, Torsten T; Welte, Tobias; Strauss, Richard; Bischoff, Helge; Richter, Klaus; Ewig, Santiago
2013-08-01
We investigated rates and predictors of ventilatory support during hospitalization in seemingly not severely compromised nonsurvivors of community-acquired pneumonia (CAP). We used the database from the German nationwide mandatory quality assurance program including all hospitalized patients with CAP from 2007 to 2011. We selected a population not residing in nursing homes, not bedridden, and not referred from another hospital. Predictors of ventilatory support were identified using a multivariate analysis. Overall, 563,901 patients (62.3% of the whole population) were included. Mean age was 69.4 ± 16.6 years; 329,107 (58.4%) were male. Mortality was 39,895 (7.1%). A total of 28,410 (5.0%) received ventilatory support during the hospital course, and 76.3% of nonsurvivors did not receive ventilatory support (62.6% of those aged <65 years and 78% of those aged ≥65 years). Higher age (relative risk (RR) 0.48, 95% confidence interval (CI) 0.44-0.51), failure to assess gas exchange (RR 0.18, 95% CI 0.14-0.25) and to administer antibiotics within 8 h of hospitalization (RR 0.48, 95% CI 0.39-0.59) were predictors of not receiving ventilatory support during hospitalization. Death from CAP occurred significantly earlier in the nonventilated group (8.2 ± 8.9 vs. 13.1 ± 14.1 days; p < 0.0001). The number of nonsurvivors without obvious reasons for withholding ventilatory support is disturbingly high, particularly in younger patients. Both performance predictors for not being ventilated remain ambiguous, because they may reflect either treatment restrictions or deficient clinical performance. Elucidating this ambiguity will be part of the forthcoming update of the quality assurance program.
Ding, Shaojie; Qian, Min; Qian, Hong; Zhang, Xuejuan
2016-12-28
The stochastic Hodgkin-Huxley model is one of the best-known examples of piecewise deterministic Markov processes (PDMPs), in which the electrical potential across a cell membrane, V(t), is coupled with a mesoscopic Markov jump process representing the stochastic opening and closing of ion channels embedded in the membrane. The rates of the channel kinetics, in turn, are voltage-dependent. Due to this interdependence, an accurate and efficient sampling of the time evolution of the hybrid stochastic systems has been challenging. The current exact simulation methods require solving a voltage-dependent hitting time problem for multiple path-dependent intensity functions with random thresholds. This paper proposes a simulation algorithm that approximates an alternative representation of the exact solution by fitting the log-survival function of the inter-jump dwell time, H(t), with a piecewise linear one. The latter uses interpolation points that are chosen according to the time evolution of the H(t), as the numerical solution to the coupled ordinary differential equations of V(t) and H(t). This computational method can be applied to all PDMPs. Pathwise convergence of the approximated sample trajectories to the exact solution is proven, and error estimates are provided. Comparison with a previous algorithm that is based on piecewise constant approximation is also presented.
NASA Astrophysics Data System (ADS)
Jung, Haesun; Choi, Sungju; Jang, Jun Tae; Yoon, Jinsu; Lee, Juhee; Lee, Yongwoo; Rhee, Jihyun; Ahn, Geumho; Yu, Hye Ri; Kim, Dong Myong; Choi, Sung-Jin; Kim, Dae Hwan
2018-02-01
We propose a universal model for bias-stress (BS)-induced instability in the inkjet-printed carbon nanotube (CNT) networks used in field-effect transistors (FETs). By combining two experimental methods, i.e., a comparison between air and vacuum BS tests and interface trap extraction, BS instability is explained regardless of either the BS polarity or ambient condition, using a single platform constituted by four key factors: OH- adsorption/desorption followed by a change in carrier concentration, electron concentration in CNT channel corroborated with H2O/O2 molecules in ambient, charge trapping/detrapping, and interface trap generation. Under negative BS (NBS), the negative threshold voltage shift (ΔVT) is dominated by OH- desorption, which is followed by hole trapping in the interface and/or gate insulator. Under positive BS (PBS), the positive ΔVT is dominated by OH- adsorption, which is followed by electron trapping in the interface and/or gate insulator. This instability is compensated by interface trap extraction; PBS instability is slightly more complicated than NBS instability. Furthermore, our model is verified using device simulation, which gives insights on how much each mechanism contributes to BS instability. Our result is potentially useful for the design of highly stable CNT-based flexible circuits in the Internet of Things wearable healthcare era.
Kosmidou, Ioanna; Embacher, Monica; McAndrew, Thomas; Dizon, José M; Mehran, Roxana; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W
2017-11-15
The prevalence and impact of early ventricular arrhythmias (ventricular tachycardia [VT]/ventricular fibrillation [VF]) occurring before mechanical revascularization for acute ST segment elevation myocardial infarction (STEMI) treated with percutaneous coronary intervention are poorly understood. We sought to investigate the association between early VT/VF and long-term clinical outcomes using data from the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction trial. Among 3,602 patients with STEMI, 108 patients (3.0%) had early VT/VF. Baseline clinical characteristics were similar in patients with versus without early VT/VF. Patients with early VT/VF had shorter symptom-to-balloon times and lower left ventricular ejection fraction and underwent more frequent thrombectomy compared with patients without early VT/VF. Adjusted 3-year rates of all-cause death (15.7% vs 6.5%; adjusted hazard ratio 2.62, 95% confidence interval 1.48 to 4.61, p <0.001) and stent thrombosis (13.7% vs 5.7%; adjusted hazard ratio 2.74, 95% confidence interval 1.52 to 4.93, p <0.001) were significantly higher in patients with early VT/VF compared with patients without early VT/VF. In conclusion, in the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction trial, VT/VF occurring before coronary angiography and revascularization in patients with STEMI was strongly associated with increased 3-year rates of death and stent thrombosis. Further investigation into the mechanisms underlying the increased risk of early stent thrombosis in patients with early VT/VF is required. Copyright © 2017 Elsevier Inc. All rights reserved.
Roach, R E J; Lijfering, W M; Helmerhorst, F M; Cannegieter, S C; Rosendaal, F R; van Hylckama Vlieg, A
2013-01-01
Oral contraception (OC) and postmenopausal hormone therapy (HT) can be used to alleviate menopausal symptoms. However, the risk of venous thrombosis (VT) associated with OC use in women over 50 years old has never been assessed and the two preparations have not been directly compared. To determine and compare the risk of VT associated with OC and HT use. From a large case-control study, 2550 women aged over 50 years old, 1082 patients with a first VT and 1468 controls, were included. Odds ratios (ORs) and 95% confidence intervals for VT were calculated for OC-users (164 patients and 54 controls) and HT-users (88 patients and 102 controls) compared with non-hormone users (823 patients and 1304 controls). OC-users had a 6.3-fold (4.6-9.8) increased risk of VT. This ranged from 5.4 (3.3-8.9) for preparations containing levonorgestrel to 10.2 (4.8-21.7) for desogestrel. The VT-risk associated with oral HT use was 4.0 (1.8-8.2) for conjugated equine estrogen combined with medroxyprogesterone acetate and 3.9 (1.5-10.7) for micronized estradiol combined with norethisterone acetate. Non-oral HT did not increase the risk of VT: OR 1.1 (0.6-1.8). Relative risk estimates were further increased in hormone users with factor V Leiden, prothrombin G20210A or blood group non-O and hormone users with a family history of VT. In this study, non-oral HT seemed to be the safest hormonal preparation in women over 50 years old. OC use increased the VT risk the most, especially in women with inherited thrombophilia or a family history of VT. © 2012 International Society on Thrombosis and Haemostasis.
Soliz, Jorge; Soulage, Christophe; Borter, Emanuela; van Patot, Martha Tissot; Gassmann, Max
2008-08-01
Proteins harboring a Per-Arnt-Sim (PAS) domain are versatile and allow archaea, bacteria, and plants to sense oxygen partial pressure, as well as light intensity and redox potential. A PAS domain associated with a histidine kinase domain is found in FixL, the oxygen sensor molecule of Rhizobium species. PASKIN is the mammalian homolog of FixL, but its function is far from being understood. Using whole body plethysmography, we evaluated the ventilatory response to acute and chronic hypoxia of homozygous deficient male and female PASKIN mice (Paskin-/-). Although only slight ventilatory differences were found in males, female Paskin-/- mice increased ventilatory response to acute hypoxia. Unexpectedly, females had an impaired ability to reach ventilatory acclimatization in response to chronic hypoxia. Central control of ventilation occurs in the brain stem respiratory centers and is modulated by catecholamines via tyrosine hydroxylase (TH) activity. We observed that TH activity was altered in male and female Paskin-/- mice. Peripheral chemoreceptor effects on ventilation were evaluated by exposing animals to hyperoxia (Dejours test) and domperidone, a peripheral ventilatory stimulant drug directly affecting the carotid sinus nerve discharge. Male and female Paskin-/- had normal peripheral chemosensory (carotid bodies) responses. In summary, our observations suggest that PASKIN is involved in the central control of hypoxic ventilation, modulating ventilation in a gender-dependent manner.
Low Cardiorespiratory Fitness is Partially Linked to Ventilatory Factors in Obese Adolescents.
Mendelson, Monique; Michallet, Anne-Sophie; Tonini, Julia; Favre-Juvin, Anne; Guinot, Michel; Wuyam, Bernard; Flore, Patrice
2016-02-01
To examine the role of ventilatory constraint on cardiorespiratory fitness in obese adolescents. Thirty obese adolescents performed a maximal incremental cycling exercise and were divided into 2 groups based on maximal oxygen uptake (VO2peak): those presenting low (L; n = 15; VO2peak: 72.9 ± 8.6% predicted) or normal (N; n = 15; VO2peak: 113.6 ± 19.2% predicted) cardiorespiratory fitness. Both were compared with a group of healthy controls (C; n = 20; VO2peak: 103.1 ± 11.2% predicted). Ventilatory responses were explored using the flow volume loop method. Cardiorespiratory fitness (VO2peak, in % predicted) was lower in L compared with C and N and was moderately associated with the percent predicted forced vital capacity (FVC) (r = .52; p < .05) in L. At peak exercise, end inspiratory point was lower in L compared with N and C (77.4 ± 8.1, 86.4 ± 7.7, and 89.9 ± 7.6% FVC in L, N, and C, respectively; p < .05), suggesting an increased risk of ventilatory constraint in L, although at peak exercise this difference could be attributed to the lower maximal ventilation in L. Forced vital capacity and ventilatory strategy to incremental exercise slightly differed between N and L. These results suggest a modest participation of ventilatory factors to exercise intolerance.
DNA Inversion on Conjugative Plasmid pVT745
Chen, Jinbiao; Leblanc, Donald J.; Galli, Dominique M.
2002-01-01
Plasmid pVT745 from Actinobacillus actinomycetemcomitans strain VT745 can be transferred to other A. actinomycetemcomitans strains at a frequency of 10−6. Screening of transconjugants revealed that the DNA of pDMG21A, a pVT745 derivative containing a kanamycin resistance gene, displayed a structural rearrangement after transfer. A 9-kb segment on the plasmid had switched orientation. The inversion was independent of RecA and required the activity of the pVT745-encoded site-specific recombinase. This recombinase, termed Inv, was highly homologous to invertases of the Din family. Two recombination sites of 22 bp, which are arranged in opposite orientation and which function as DNA crossover sequences, were identified on pVT745. One of the sites was located adjacent to the 5′ end of the invertase gene, inv. Inversion of the 9-kb segment on pVT745 derivatives has been observed in all A. actinomycetemcomitans strains tested except for the original host, VT745. This would suggest that a host factor that is either inactive or absent in VT745 is required for efficient recombination. Inactivation of the invertase in the donor strain resulted in a 1,000-fold increase in the number of transconjugants upon plasmid transfer. It is proposed that an activated invertase causes the immediate loss of the plasmid in most recipient cells after mating. No biological role has been associated with the invertase as of yet. PMID:12374826
Yang, Xiaolong; Yu, Zhijun; He, Yanjie; Xu, Xiaoli; Gao, Zhihua; Wang, Hui; Chen, Jie; Liu, Jingze
2015-03-01
Vitellin (Vt) was purified from eggs of parthenogenetic bush tick Haemaphysalis longicornis by gel filtration and ion exchange chromatography. Our results revealed that only one single Vt existed in parthenogenetic bush tick, and the purified Vt was proved to be a hemoglycolipoprotein consisting of nine polypeptides with molecular weights of 203, 147, 126, 82, 74, 70, 61, 47 and 31 kDa, respectively. Polyclonal antibody and monoclonal antibody against Vt were produced using the purified Vt. The change in vitellogenin (Vg) and Vt levels over time of the parthenogenetic H. longicornis was established, and the Vg content in haemolymph and Vt in ovary at different feeding or engorgement statuses was also determined using a double antibody sandwich enzyme-linked immunosorbent assay. The Vg level in haemolymph was distinctly increased on the day of engorgement (1.785 mg/mL) and continued to increase until 2nd day post-engorgement (5.611 mg/mL). There was a slight decrease in Vg level after 4 days of engorgement, and a second peak was observed on day 2 post-oviposition (10.774 mg/mL). Subsequently, Vg content continuously decreased and reached a low level on the 10th day post-oviposition. The Vt content in ovary continuously increased once the female reached its critical weight (0.024 mg per female), and reached the maximum level on day 2 post-oviposition (1.942 mg per female). Afterwards, Vt content rapidly decreased.
Occurrence of verotoxin-producing Escherichia coli in dairy heifers grazing an irrigated pasture.
Thran, B H; Hussein, H S; Hall, M R; Khaiboullina, S F
2001-02-28
Verotoxin-producing Escherichia coli (VTEC) produce one or two toxins known as VT1 and VT2. These toxins have been associated with several human illnesses. Dairy cattle harboring VTEC represent a potential health hazard because they enter the food chain as ground beef. The objective of this study was to assess the occurrence of VTEC in dairy heifers. A total of 91 fecal samples were rectally collected during four periods (spring, summer, fall, and winter of 1999) from 23 heifers. A random sample (n=530) of potential VTEC isolates were tested for verotoxicity and were screened by the polymerase chain reaction (PCR) for presence or absence of VT1 and/or VT2 genes. Thirteen isolates from two heifers (from the winter collection) were verotoxic and were confirmed as E. coli. VTEC were only detected during winter with an occurrence rate of 9.5%. Using PCR, five isolates had the VT1 gene while the remaining eight had the VT2 gene. The sequence and expression of VT1 and VT2 genes were confirmed. No E. coli O157:H7 was detected, but serotyping revealed that the five VT1-positive isolates were O26:NM (a non-motile strain of O26). The remaining eight isolates were untypeable. Identification of VTEC-positive cattle before slaughter is a critical step in any on-farm strategy to minimize the risk of beef contamination with such pathogens.
Genetics of Venous Thrombosis: Insights from a New Genome Wide Association Study
Germain, Marine; Saut, Noémie; Greliche, Nicolas; Dina, Christian; Lambert, Jean-Charles; Perret, Claire; Cohen, William; Oudot-Mellakh, Tiphaine; Antoni, Guillemette; Alessi, Marie-Christine; Zelenika, Diana; Cambien, François; Tiret, Laurence; Bertrand, Marion; Dupuy, Anne-Marie; Letenneur, Luc; Lathrop, Mark; Emmerich, Joseph; Amouyel, Philippe; Trégouët, David-Alexandre; Morange, Pierre-Emmanuel
2011-01-01
Background Venous Thrombosis (VT) is a common multifactorial disease associated with a major public health burden. Genetics factors are known to contribute to the susceptibility of the disease but how many genes are involved and their contribution to VT risk still remain obscure. We aimed to identify genetic variants associated with VT risk. Methodology/Principal Findings We conducted a genome-wide association study (GWAS) based on 551,141 SNPs genotyped in 1,542 cases and 1,110 controls. Twelve SNPs reached the genome-wide significance level of 2.0×10−8 and encompassed four known VT-associated loci, ABO, F5, F11 and FGG. By means of haplotype analyses, we also provided novel arguments in favor of a role of HIVEP1, PROCR and STAB2, three loci recently hypothesized to participate in the susceptibility to VT. However, no novel VT-associated loci came out of our GWAS. Using a recently proposed statistical methodology, we also showed that common variants could explain about 35% of the genetic variance underlying VT susceptibility among which 3% could be attributable to the main identified VT loci. This analysis additionally suggested that the common variants left to be identified are not uniformly distributed across the genome and that chromosome 20, itself, could contribute to ∼7% of the total genetic variance. Conclusions/Significance This study might also provide a valuable source of information to expand our understanding of biological mechanisms regulating quantitative biomarkers for VT. PMID:21980494
Estrogen attenuates the cardiovascular and ventilatory responses to central command in cats.
Hayes, Shawn G; Moya Del Pino, Nicolas B; Kaufman, Marc P
2002-04-01
Static exercise is well known to increase heart rate, arterial blood pressure, and ventilation. These increases appear to be less in women than in men, a difference that has been attributed to an effect of estrogen on neuronal function. In decerebrate male cats, we examined the effect of estrogen (17beta-estradiol; 0.001, 0.01, 0.1, and 1.0 microg/kg iv) on the cardiovascular and ventilatory responses to central command and the exercise pressor reflex, the two neural mechanisms responsible for evoking the autonomic and ventilatory responses to exercise. We found that 17beta-estradiol, in each of the three doses tested, attenuated the pressor, cardioaccelerator, and phrenic nerve responses to electrical stimulation of the mesencephalic locomotor region (i.e., central command). In contrast, none of the doses of 17beta-estradiol had any effect on the pressor, cardioaccelerator, and ventilatory responses to static contraction or stretch of the triceps surae muscles. We conclude that, in decerebrate male cats, estrogen injected intravenously attenuates cardiovascular and ventilatory responses to central command but has no effect on responses to the exercise pressor reflex.
Effect of Wheelchair Frame Material on Users' Mechanical Work and Transmitted Vibration
Aissaoui, Rachid
2014-01-01
Wheelchair propulsion exposes the user to a high risk of shoulder injury and to whole-body vibration that exceeds recommendations of ISO 2631-1:1997. Reducing the mechanical work required to travel a given distance (WN-WPM, weight-normalized work-per-meter) can help reduce the risk of shoulder injury, while reducing the vibration transmissibility (VT) of the wheelchair frame can reduce whole-body vibration. New materials such as titanium and carbon are used in today's wheelchairs and are advertised to improve both parameters, but current knowledge on this matter is limited. In this study, WN-WPM and VT were measured simultaneously and compared between six folding wheelchairs (1 titanium, 1 carbon, and 4 aluminium). Ten able-bodied users propelled the six wheelchairs on three ground surfaces. Although no significant difference of WN-WPM was found between wheelchairs (P < 0.1), significant differences of VT were found (P < 0.05). The carbon wheelchair had the lowest VT. Contrarily to current belief, the titanium wheelchair VT was similar to aluminium wheelchairs. A negative correlation between VT and WN-WPM was found, which means that reducing VT may be at the expense of increasing WN-WPM. Based on our results, use of carbon in wheelchair construction seems promising to reduce VT without increasing WN-WPM. PMID:25276802
Tsai, Ching-Fent; Wang, Kun-Teng; Chen, Lih-Geeng; Lee, Chia-Jung; Tseng, Sung-Hui
2014-01-01
Abstract Vitis thunbergii Sieb. et Zucc. var. taiwaniana Lu (VT) is an indigenous plant in Taiwan that is traditionally used for promoting joint health. In this study, we used in vitro primary human chondrocytes (PHCs) and two in vivo animal models to evaluate the anti-inflammatory effects of VT on arthritis. Results showed that the water extract of the stems and roots from VT (VT-SR) was rich in flavones and phenols with 1.1 mg/g of resveratrol, 6.7 mg/g of hopeaphenol, and 5.1 mg/g of (+)-ɛ-viniferin. VT-SR significantly scavenged DPPH radicals and inhibited prostaglandin E2 (PGE2) production in lipopolysaccharide (LPS)-induced PHCs without exhibiting significant cytotoxicity. In in vivo models, the VT-SR (500 mg/kg) significantly decreased serum PGE2 and knee 2-18F-fluoro-2-deoxy-D-glucose (18F-FDG) levels in LPS-induced acute inflammatory arthritis in rabbits. In addition, dietary supplementation with VT-SR for 28 days significantly alleviated type II collagenase-induced rat osteoarthritis with improvements in weight bearing and range of motion tests. In conclusion, our results suggest that the VT-SR is a good candidate for developing dietary supplements to prevent joint deterioration and inhibit inflammation. PMID:24720858
The endophyte Verticillium Vt305 protects cauliflower against Verticillium wilt.
Tyvaert, L; França, S C; Debode, J; Höfte, M
2014-06-01
To investigate the interaction between cauliflower and the isolate VerticilliumVt305, obtained from a field suppressive to Verticillium wilt of cauliflower, and to evaluate the ability of VerticilliumVt305 to control Verticillium wilt of cauliflower caused by V. longisporum. Single and combined inoculations of VerticilliumVt305 and V. longisporum were performed on cauliflower seedlings. Symptom development was evaluated, and fungal colonization was measured in the roots, hypocotyl and stem with real-time PCR. No symptoms were observed after single inoculation of VerticilliumVt305, although it colonized the plant tissues. Pre-inoculation of VerticilliumVt305 reduced symptom development and colonization of plant tissues by V. longisporum. VerticilliumVt305 is an endophyte on cauliflower plants and showed effective biological control of V. longisporum in controlled conditions. This work can contribute to the development of a sustainable control measure of V. longisporum in Brassicaceae hosts, which is currently not available. Additionally, this study provides evidence for the different roles of Verticillium species present in the agro-ecosystem. © 2014 The Society for Applied Microbiology.
Ning, Xiaohui; Ye, Xuerui; Si, Yanhua; Yang, Zihe; Zhao, Yunzi; Sun, Qi; Chen, Ruohan; Tang, Min; Chen, Keping; Zhang, Xiaoli; Zhang, Shu
2018-03-21
We investigated the prevalence of ventricular tachycardia/ventricular fibrillation (VT/VF) in Post-infarction left ventricular aneurysm (PI-LVA) patients and analyze clinical outcomes in patients presenting with VT/VF. 575 PI-LVA patients were enrolled and investigated by logistic regression analysis. Patients with VT/VF were followed up, the composite primary endpoint was cardiac death and appropriate ICD/external shocks. The incidence of sustained VT/VF was 11%. Logistical regression analysis showed male gender, enlarged LV end diastolic diameter (LVEDD) and higher NYHA class were correlated with VT/VF development. During follow up of 46 ± 15 months, 19 out of 62(31%) patients reached study end point. Multivariate Cox regression analysis revealed that enlarged LVEDD and moderate/severe mitral regurgitation (MR) were independently predictive of clinical outcome. Male gender, enlarged LVEDD and higher NYHA class associated with risk of sustained VT/VF in PI-LVA patients. Among VT/VF positive patients, enlarged LVEDD and moderate/severe MR independently predicted poor clinical prognosis. Copyright © 2018. Published by Elsevier Inc.
Olson, Thomas P; Joyner, Michael J; Eisenach, John H; Curry, Timothy B; Johnson, Bruce D
2014-02-01
What is the central question of this study? Patients with heart failure often develop ventilatory abnormalities at rest and during exercise, but the mechanisms underlying these abnormalities remain unclear. This study investigated the influence of inhibiting afferent neural feedback from locomotor muscles on the ventilatory response during exercise in heart failure patients. What is the main finding and its importance? Our results suggest that inhibiting afferent feedback from locomotor muscle via intrathecal opioid administration significantly reduces the ventilatory response to exercise in heart failure patients. Patients with heart failure (HF) develop ventilatory abnormalities at rest and during exercise, but the mechanism(s) underlying these abnormalities remain unclear. We examined whether the inhibition of afferent neural feedback from locomotor muscles during exercise reduces exercise ventilation in HF patients. In a randomized, placebo-controlled design, nine HF patients (age, 60 ± 2 years; ejection fraction, 27 ± 2%; New York Heart Association class 2 ± 1) and nine control subjects (age, 63 ± 2 years) underwent constant-work submaximal cycling (65% peak power) with intrathecal fentanyl (impairing the cephalad projection of opioid receptor-sensitive afferents) or sham injection. The hypercapnic ventilatory response was measured to determine whether cephalad migration of fentanyl occurred. There were no differences in hypercapnic ventilatory response within or between groups in either condition. Despite a lack of change in ventilation, tidal volume or respiratory rate, HF patients had a mild increase in arterial carbon dioxide (P(aCO(2)) and a decrease in oxygen (P(aO(2)); P < 0.05 for both) at rest. The control subjects demonstrated no change in P(aCO(2)), P(aO(2)), ventilation, tidal volume or respiratory rate at rest. In response to fentanyl during exercise, HF patients had a reduction in ventilation (63 ± 6 versus 44 ± 3 l min(-1), P < 0.05) due to a lower respiratory rate (30 ± 1 versus 26 ± 2 breaths min(-1), P < 0.05). The reduced ventilation resulted in lower P aO 2 (97.6 ± 2.5 versus 79.5 ± 3.0 mmHg, P < 0.05) and increased P(aCO(2)) (37.3 ± 0.9 versus 43.5 ± 1.1 mmHg, P < 0.05), with significant improvement in ventilatory efficiency (reduction in the ventilatory equivalent for carbon dioxide; P < 0.05 for all). The control subjects had no change in ventilation or measures of arterial blood gases. These data suggest that inhibition of afferent feedback from locomotor muscle significantly reduces the ventilatory response to exercise in HF patients.
NASA Astrophysics Data System (ADS)
Pradeep, Krishna; Poiroux, Thierry; Scheer, Patrick; Juge, André; Gouget, Gilles; Ghibaudo, Gérard
2018-07-01
This work details the analysis of wafer level global process variability in 28 nm FD-SOI using split C-V measurements. The proposed approach initially evaluates the native on wafer process variability using efficient extraction methods on split C-V measurements. The on-wafer threshold voltage (VT) variability is first studied and modeled using a simple analytical model. Then, a statistical model based on the Leti-UTSOI compact model is proposed to describe the total C-V variability in different bias conditions. This statistical model is finally used to study the contribution of each process parameter to the total C-V variability.
Effect of atenolol on ventilatory and cardiac function in asthma.
Vilsvik, J S; Schaanning, J
1976-01-01
The effects on ventilatory and cardiac function of atenolol, a new cardioselective beta-adrenoceptor blocking agent, were compared with those of practolol in a double-blind trial in 12 patients with asthma. Both drugs impaired ventilatory function--atenolol insignificantly and practolol significantly. Atenolol was if anything more cardioselective than practolol. Neither drug interfered significantly with the bronchodilator response to inhaled isoprenaline. Atenolol is suitable for use in patients for whom practolol would formerly have been chosen because of its cardioselectivity. PMID:8188
Desensitization of the cough reflex by exercise and voluntary isocapnic hyperpnea.
Lavorini, Federico; Fontana, Giovanni A; Chellini, Elisa; Magni, Chiara; Duranti, Roberto; Widdicombe, John
2010-05-01
Little is known about the effects of exercise on the sensory and cognitive aspects of coughing evoked by inhalation of tussigenic agents. The threshold for the cough reflex induced by inhalation of increasing nebulizer outputs of ultrasonically nebulized distilled water (fog), an index of cough reflex sensitivity, was assessed in twelve healthy humans in control conditions, during exercise and during voluntary isocapnic hyperpnea (VIH) at the same ventilatory level as the exercise. The intensity of the urge to cough (UTC), a cognitive component of coughing, was recorded throughout the trials on a linear scale. The relationships between inhaled fog nebulizer outputs and the correspondingly evoked UTC values, an index of the perceptual magnitude of the UTC sensitivity, were also calculated. Cough appearance was always assessed audiovisually. At an exercise level of 80% of anaerobic threshold, the median cough threshold was increased from a control value of 0.73 to 2.22 ml/min (P<0.01), i.e., cough sensitivity was downregulated. With VIH, the threshold increased from 0.73 to 2.22 ml/min (P<0.01), a similar downregulation. With exercise and VIH compared with control, mean UTC values at cough threshold were unchanged, i.e., control, 3.83 cm; exercise, 3.12 cm; VIH, 4.08 cm. The relationship of the fog nebulizer output/UTC value was linear in control conditions and logarithmic during both exercise and VIH. The perception of the magnitude of the UTC seems to be influenced by signals or sensations arising from exercising limb and thoracic muscles and/or by higher nervous (cortical) mechanisms. The results indicate that the adjustments brought into action by exercise-induced or voluntary hyperpnea exert inhibitory influences on the sensory and cognitive components of fog-induced cough.
Yaksh, Ameeta; Kik, Charles; Knops, Paul; Zwiers, Korinne; van Ettinger, Maarten J B; Manintveld, Olivier C; de Wijs, Marcel C J; van der Kemp, Peter; Bogers, Ad J J C; de Groot, Natasja M S
2016-07-08
Early postoperative ventricular tachyarrhythmia (PoVT) after left ventricular assist device (LVAD) implantation are common and associated with higher mortality-rates. At present, there is no data on initiation of these PoVT and the role of alterations in cardiac hemodynamics. A LVAD was implanted in a patient with end-stage heart failure due to a ischemic cardiomyopathy. Alterations in cardiac rhythm and hemodynamics preceding PoVT-episodes during the first five postoperative days were examined by using continuous recordings of cardiac rhythm and various hemodynamic parameters. All PoVT (N=120) were monomorphic, most often preceded by short-long-short-sequences or regular SR and initiated by ventricular runs. Prior to PoVT, mean arterial pressure decreased; heart rate and ST-segments deviations increased. PoVT are caused by different underlying electrophysiological mechanisms. Yet, they are all monomorphic and preceded by hemodynamic deterioration due to myocardial ischemia.
George, W D; Godfrey, R W; Ketring, R C; Vinson, M C; Willard, S T
2014-11-01
Digital infrared thermal imaging (DITI) using a thermal camera has potential to be a useful tool for the production animal industry. Thermography has been used in both humans and a wide range of animal species to measure body temperature as a method to detect injury or inflammation. The objective of these experiments was to compare the temperature of the eye (EYE) or muzzle (MUZ) measured using DITI to vaginal (VT) and rectal temperature (RT) as measures of core body temperature in hair sheep and beef cattle. In Exp.1 EYE, VT and RT were measured in lactating, multiparous hair sheep ewes (St. Croix White, n = 10, and Dorper × St. Croix White, n = 10) in a non-febrile state 5 times over a 48-h period. Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.95), EYE and RT (r = 0.76) and EYE and VT (r = 0.77). In Exp. 2 EYE, MUZ, VT and RT were measured in multiparous, lactating ewes (St. Croix White, n = 2, and Barbados Blackbelly, n = 12) at -12, -1, 0, 1, 2, 3, 4, 6, 12, 24, 36, and 48 h after being administered lipopolysaccharide (LPS; n = 7; 0.2 µg/kg BW, i.v.) or saline (n = 7; 0.5 mL, i.v.). Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. When data were combined across treatments (LPS and saline) there was a high correlation (P < 0.001) between VT and RT (r = 0.96), EYE and RT (r = 0.82), MUZ and RT (r = 0.72), and EYE and VT (r = 0.93). In Exp. 3 EYE, MUZ, VT and RT were measured in multiparous, non-lactating, pregnant Senepol cattle (n = 44) between 0900 and 1200 h on a single day. A digital veterinary thermometer was used to measure both VT and RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.78), a moderate correlation (P < 0.001) between VT and EYE (r = 0.52), RT and EYE (r = 0.58) and EYE and MUZ (r = 0.48). There was no correlation (P > 0.10) between RT or VT and MUZ. The findings of these three studies indicate that temperature of the eye, measured using DITI, can be used as an indicator of core body temperature in hair sheep and beef cattle as an alternative to using vaginal or rectal temperature.
Spirometric evaluation of ventilatory function in adult male cigarette smokers in Sokoto metropolis.
Isah, Muhammad D; Makusidi, Muhammad A; Abbas, Aminu; Okpapi, Juliana U; Njoku, Chibueze H; Abba, Abdullahi A
2017-01-01
Cigarette smoking is a widespread social habit in Nigeria with extensive deleterious multisystemic effect. Ventilatory dysfunction is one of the cigarette smoking-related illnesses that affect the respiratory system. Spirometry is an investigative method that can be used for the early detection of ventilatory dysfunction even before the onset of the symptoms. A questionnaire adapted from the European Community Respiratory Health Survey was administered to collect demographic, clinical, and cigarette smoking data. Ventilatory function test was conducted using Clement Clarke (One Flow) Spirometer, version 1.3. The highest value of each ventilatory function index was chosen for analysis, and individual(s) with ventilatory dysfunction were subjected to post bronchodilator spirometry. For the purpose of this research, 150 participants who were currently cigarette smokers were enrolled, and 50 apparently healthy, age-matched individuals who were never smokers served as controls in the ratio of 3:1. Eighty percent of participants and 68% of controls were aged 40 years or below. The mean age of participants (34.27 ± 8.91 years) and the controls (35.08 ± 10.35 years) was not significantly different (P = 0.592). Similarly, there were no statistically significant differences between the mean anthropometric indices (weight: P = 0.663, height: P = 0.084, and body mass index: P = 0.099) of both participants and controls. The mean values of FEV1 (forced expiratory flow in one second) and FEV1/FVC (FVC=forced vital capacity) were lower in the participants compared to the controls, and this difference was statistically significant (P < 0.001). There was a weak negative correlation between pack-years of cigarette smoking and FEV1 (r = -0.237 and P = 0.004). Obstructive ventilatory defect was found among six study participants (4%) and two controls (4%). Cigarette smoking is associated with decline in ventilatory function test indices (FEV1 and FEV1/FVC) in adult males. Decline in FEV1 is directly related to pack-years of cigarette smoking.
Minocycline blocks glial cell activation and ventilatory acclimatization to hypoxia.
Stokes, Jennifer A; Arbogast, Tara E; Moya, Esteban A; Fu, Zhenxing; Powell, Frank L
2017-04-01
Ventilatory acclimatization to hypoxia (VAH) is the time-dependent increase in ventilation, which persists upon return to normoxia and involves plasticity in both central nervous system respiratory centers and peripheral chemoreceptors. We investigated the role of glial cells in VAH in male Sprague-Dawley rats using minocycline, an antibiotic that inhibits microglia activation and has anti-inflammatory properties, and barometric pressure plethysmography to measure ventilation. Rats received either minocycline (45mg/kg ip daily) or saline beginning 1 day before and during 7 days of chronic hypoxia (CH, Pi O 2 = 70 Torr). Minocycline had no effect on normoxic control rats or the hypercapnic ventilatory response in CH rats, but minocycline significantly ( P < 0.001) decreased ventilation during acute hypoxia in CH rats. However, minocycline administration during only the last 3 days of CH did not reverse VAH. Microglia and astrocyte activation in the nucleus tractus solitarius was quantified from 30 min to 7 days of CH. Microglia showed an active morphology (shorter and fewer branches) after 1 h of hypoxia and returned to the control state (longer filaments and extensive branching) after 4 h of CH. Astrocytes increased glial fibrillary acidic protein antibody immunofluorescent intensity, indicating activation, at both 4 and 24 h of CH. Minocycline had no effect on glia in normoxia but significantly decreased microglia activation at 1 h of CH and astrocyte activation at 24 h of CH. These results support a role for glial cells, providing an early signal for the induction but not maintenance of neural plasticity underlying ventilatory acclimatization to hypoxia. NEW & NOTEWORTHY The signals for neural plasticity in medullary respiratory centers underlying ventilatory acclimatization to chronic hypoxia are unknown. We show that chronic hypoxia activates microglia and subsequently astrocytes. Minocycline, an antibiotic that blocks microglial activation and has anti-inflammatory properties, also blocks astrocyte activation in respiratory centers during chronic hypoxia and ventilatory acclimatization. However, minocycline cannot reverse ventilatory acclimatization after it is established. Hence, glial cells may provide signals that initiate but do not sustain ventilatory acclimatization. Copyright © 2017 the American Physiological Society.
Minocycline blocks glial cell activation and ventilatory acclimatization to hypoxia
Arbogast, Tara E.; Moya, Esteban A.; Fu, Zhenxing; Powell, Frank L.
2017-01-01
Ventilatory acclimatization to hypoxia (VAH) is the time-dependent increase in ventilation, which persists upon return to normoxia and involves plasticity in both central nervous system respiratory centers and peripheral chemoreceptors. We investigated the role of glial cells in VAH in male Sprague-Dawley rats using minocycline, an antibiotic that inhibits microglia activation and has anti-inflammatory properties, and barometric pressure plethysmography to measure ventilation. Rats received either minocycline (45mg/kg ip daily) or saline beginning 1 day before and during 7 days of chronic hypoxia (CH, PiO2 = 70 Torr). Minocycline had no effect on normoxic control rats or the hypercapnic ventilatory response in CH rats, but minocycline significantly (P < 0.001) decreased ventilation during acute hypoxia in CH rats. However, minocycline administration during only the last 3 days of CH did not reverse VAH. Microglia and astrocyte activation in the nucleus tractus solitarius was quantified from 30 min to 7 days of CH. Microglia showed an active morphology (shorter and fewer branches) after 1 h of hypoxia and returned to the control state (longer filaments and extensive branching) after 4 h of CH. Astrocytes increased glial fibrillary acidic protein antibody immunofluorescent intensity, indicating activation, at both 4 and 24 h of CH. Minocycline had no effect on glia in normoxia but significantly decreased microglia activation at 1 h of CH and astrocyte activation at 24 h of CH. These results support a role for glial cells, providing an early signal for the induction but not maintenance of neural plasticity underlying ventilatory acclimatization to hypoxia. NEW & NOTEWORTHY The signals for neural plasticity in medullary respiratory centers underlying ventilatory acclimatization to chronic hypoxia are unknown. We show that chronic hypoxia activates microglia and subsequently astrocytes. Minocycline, an antibiotic that blocks microglial activation and has anti-inflammatory properties, also blocks astrocyte activation in respiratory centers during chronic hypoxia and ventilatory acclimatization. However, minocycline cannot reverse ventilatory acclimatization after it is established. Hence, glial cells may provide signals that initiate but do not sustain ventilatory acclimatization. PMID:28100653
Moderate physical exercise induces the oxidation of human blood protein thiols.
Inayama, Takayo; Oka, Jun; Kashiba, Misato; Saito, Makoto; Higuchi, Mitsuru; Umegaki, Keizo; Yamamoto, Yorihiro; Matsuda, Mitsuo
2002-03-15
Exercise is known to induce the oxidation of blood low-molecular-weight (LMW) thiols such as reduced glutathione (GSH). We previously reported that full-marathon running induced a decrease in human plasma levels of protein-bound sulfhydryl groups (p-SHs). Moderate exercise, a 30-min running at the intensity of the individual ventilatory threshold, performed by untrained healthy females caused a significant decrease in erythrocyte levels of p-SHs (mostly hemoglobin cysteine residues) and LMW thiols, but their levels returned to each baseline by 2 h. No significant change in plasma LMW thiols was observed. However, plasma levels of p-SHs significantly decreased after running and remained unchanged after 24 h. These results suggest that moderate exercise causes the oxidation of blood thiols, especially protein-bound thiols.
The role of pore fluids on deforming volcanic rocks: an experimental study
NASA Astrophysics Data System (ADS)
Fazio, Marco; Benson, Philip; Vinciguerra, Sergio; Meredith, Philip
2015-04-01
Pore fluids play an important role on the process of the deformation of rocks. Not only it affects the mechanical properties and the elastic velocities of the material, but it is also responsible in the generation of a whole kind of seismicity, characterized by lower frequency and longer tail (i.e. Long Period, LP, and Hybrid events) than the Volcano-Tectonic (VT) signals, generated by simple shear. While great progress has been made in understanding VT events, LPs, Hybrid signals and the transition between these types of activity are not fully understood yet. This study, aiming in particular on the transition between VT and Hybrid events, shows the results of triaxial experiments on a volcanic rock, run both in dry and wet conditions, to better understand the role of the pore fluids on the final stage of the deformation tests, when the sample is approaching failure. This is achieved through a servo-controlled triaxial testing machine and a state-of the-art acoustic emissions (AEs) kit, composed by an array of 12 piezoelectric sensors surrounding the sample and by both a "triggered" unit, where the events are recorded only if a certain threshold is reached, and a "continuous" unit, where the data is recorded from the beginning to the end of the acquisition, fundamental when the AEs grow exponentially and the triggered unit cannot store at the same rate. The use of sensors of different dominant frequency allows us to better investigate the events occurring as the sample is approaching failure. In both conditions we observe a decrease of the dominant frequency of the seismic activity, due to two different processes: in dry conditions the coalescence of fractures, eventually leading to the major shear zone, creates relatively low-frequency VT events; the same occurs in wet conditions, but the movement of fluids, eased by the merging of the cracks, generates hybrid events. These two type of seismicity are then distinguished in terms of their source mechanism components, where the low-frequency VTs are characterized by a higher DC component, while hybrid events show a greater CLVD one. These results may have a great impacts in the failure forecasting models, not only in volcanic settings, but wherever the pore fluids play an important role on the stability of the rock mass.
Volume Transmission in Central Dopamine and Noradrenaline Neurons and Its Astroglial Targets.
Fuxe, Kjell; Agnati, Luigi F; Marcoli, Manuela; Borroto-Escuela, Dasiel O
2015-12-01
Already in the 1960s the architecture and pharmacology of the brainstem dopamine (DA) and noradrenaline (NA) neurons with formation of vast numbers of DA and NA terminal plexa of the central nervous system (CNS) indicated that they may not only communicate via synaptic transmission. In the 1980s the theory of volume transmission (VT) was introduced as a major communication together with synaptic transmission in the CNS. VT is an extracellular and cerebrospinal fluid transmission of chemical signals like transmitters, modulators etc. moving along energy gradients making diffusion and flow of VT signals possible. VT interacts with synaptic transmission mainly through direct receptor-receptor interactions in synaptic and extrasynaptic heteroreceptor complexes and their signaling cascades. The DA and NA neurons are specialized for extrasynaptic VT at the soma-dendrtitic and terminal level. The catecholamines released target multiple DA and adrenergic subtypes on nerve cells, astroglia and microglia which are the major cell components of the trophic units building up the neural-glial networks of the CNS. DA and NA VT can modulate not only the strength of synaptic transmission but also the VT signaling of the astroglia and microglia of high relevance for neuron-glia interactions. The catecholamine VT targeting astroglia can modulate the fundamental functions of astroglia observed in neuroenergetics, in the Glymphatic system, in the central renin-angiotensin system and in the production of long-distance calcium waves. Also the astrocytic and microglial DA and adrenergic receptor subtypes mediating DA and NA VT can be significant drug targets in neurological and psychiatric disease.
Gayraud, Jerome; Ramonatxo, Michele; Rivier, François; Humberclaude, Véronique; Petrof, Basil; Matecki, Stefan
2010-06-01
The aim of this longitudinal study was to precise, in children with Duchenne muscular dystrophy, the respective functional interest of ventilatory parameters (Vital capacity, total lung capacity and forced expiratory volume in one second [FEV(1)]) in comparison to maximal inspiratory pressure (Pimax) during growth. In ten boys the mean age of 9.1 +/- 1 years) to mean age of 16 +/- 1.4 years followed over a period of 7 years, we found that: (1) ventilatory parameters expressed in percentage of predicted value, after a normal ascending phase, start to decrease between 11 and 12 years, (2) Pimax presented only a decreasing phase since the beginning of the study and thus was already at 67% of predicted value at 12 years while ventilatory parameters was still normal, (3) after 12 years the mean slopes of decrease per year of vital capacity and FEV1 were higher (10.7 and 10.4%) than that of Pimax (6.9%), (4) at 15 years mean values of vital capacity and FEV1 (53.3 and 49.5% of predicted values) was simlar to that of Pimax (48.3%). In conclusion, if at early stages of the disease, Pimax is a more reliable index of respiratory impaiment than ventilatory parameters, the follow-up of ventilatory parameters, when they start to decrease, is a better indicator of disease progression and, at advanced stages they provided same information about the functional impact of disease.
Ibuprofen does not reverse ventilatory acclimatization to chronic hypoxia.
De La Zerda, D J; Stokes, J A; Do, J; Go, A; Fu, Z; Powell, F L
2017-07-27
Ventilatory acclimatization to hypoxia involves an increase in the acute hypoxic ventilatory response that is blocked by non-steroidal anti-inflammatory drugs administered during sustained hypoxia. We tested the hypothesis that inflammatory signals are necessary to sustain ventilatory acclimatization to hypoxia once it is established. Adult, rats were acclimatized to normoxia or chronic hypoxia (CH, [Formula: see text] =70Torr) for 11-12days and treated with ibuprofen or saline for the last 2days of hypoxia. Ventilation, metabolic rate, and arterial blood gas responses to O 2 and CO 2 were not affected by ibuprofen after acclimatization had been established. Immunohistochemistry and image analysis showed acute (1h) hypoxia activated microglia in a medullary respiratory center (nucleus tractus solitarius, NTS) and this was blocked by ibuprofen administered from the beginning of hypoxic exposure. Microglia returned to the control state after 7days of CH and were not affected by ibuprofen administered for 2 more days of CH. In contrast, NTS astrocytes were activated by CH but not acute hypoxia and activation was not reversed by administering ibuprofen for the last 2days of CH. Hence, ibuprofen cannot reverse ventilatory acclimatization or astrocyte activation after they have been established by sustained hypoxia. The results are consistent with a model for microglia activation or other ibuprofen-sensitive processes being necessary for the induction but not maintenance of ventilatory acclimatization to hypoxia. Copyright © 2017 Elsevier B.V. All rights reserved.
Gas exchange and ventilation during dormancy in the tegu lizard tupinambis merianae
de Andrade DV; Abe
1999-12-01
The tegu lizard Tupinambis merianae exhibits an episodic ventilatory pattern when dormant at 17 degrees C but a uniform ventilatory pattern when dormant at 25 degrees C. At 17 degrees C, ventilatory episodes were composed of 1-22 breaths interspaced by non-ventilatory periods lasting 1.8-26 min. Dormancy at the higher body temperature was accompanied by higher rates of O(2) consumption and ventilation. The increase in ventilation was due only to increases in breathing frequency with no change observed in tidal volume. The air convection requirement for O(2) did not differ at the two body temperatures. The respiratory quotient was 0.8 at 17 degrees C and 1.0 at 25 degrees C. We found no consistent relationship between expired gas composition and the start/end of the ventilatory period during episodic breathing at 17 degrees C. However, following non-ventilatory periods of increasing duration, there was an increase in the pulmonary O(2) extraction that was not coupled to an equivalent increase in elimination of CO(2) from the lungs. None of the changes in the variables studied could alone explain the initiation/termination of episodic ventilation in the tegus, suggesting that breathing episodes are shaped by a complex interaction between many variables. The estimated oxidative cost of breathing in dormant tegus at 17 degrees C was equivalent to 52.3 % of the total metabolic rate, indicating that breathing is the most costly activity during dormancy.
Pharmacological Tie2 activation in kidney transplantation.
Thamm, Kristina; Njau, Florence; Van Slyke, Paul; Dumont, Daniel J; Park, Joon-Keun; Haller, Hermann; David, Sascha
2016-09-24
To investigate the therapeutic potential of vasculotide (VT) - a Tie2 activating therapeutic - in kidney transplantation. We performed a murine MHC-mismatched renal transplant model (C57Bl/6 male into Balb/c female) with 60 min cold and 30 min warm ischemia time. 500 ng VT was administered i.p. to donor mice 1 h before organ removal. In addition, recipients received 500 ng VT i.p. directly and 3 d after surgery. Survival was monitored and remaining animals were sacrificed 28 d after transplantation. In this model, we analyzed: (1) organ function; (2) Kaplan-Meier survival; (3) organ damage (periodic acid Schiff staining) via semi-quantitative scoring [0-4 (0 = no injury/inflammation to 4 = very severe injury/inflammation)]; (4) expression of renal endothelial adhesion molecules (ICAM-1) via immunofluorescence (IF) staining, immunoblotting and qPCR; (5) infiltration of inflammatory cells (IF Gr-1, F4/80); and (6) fibrosis via staining of α-smooth muscle actin (αSMA), Sirius red staining and immunoblotting of SMAD3 activation. Exogenous activation of Tie2 with VT resulted in diminished expression of peritubular and glomerular endothelial adhesion molecules. Consequently, infiltration of inflammatory cells (analyzed as ICAM-1, Gr-1 and F4/80 positive cells) was reduced in VT-treated mice compared to controls. Additionally, VT was protective against fibrogenesis after kidney transplantation. Trends towards lower serum creatinine (vehicle: 142 ± 17 μmol/L vs VT: 94 ± 23 μmol/L), urea (vehicle: 76 ± 5 mmol/L vs VT: 60 ± 8 mmol/L) and lactate dehydrogenase (vehicle: 1288 ± 383 iU vs VT: 870 ± 275 iU) were observed on day 6 after transplantation. Kaplan-Meier survival analysis showed improved survival rates in the VT-treated mice that did not reach statistical significance (27% vs 54%, P = 0.24, n = 11 per group). Exogenous activation of Tie2 via VT might reduce infiltration of inflammatory cells into renal tissue thereby protecting the transplant from early graft dysfunction potentially affecting long-term function. Protection of the endothelial microvasculature via the Tie2 axis in the early transplant setting might hold promise as a therapeutic target.
Chlif, Mehdi; Chaouachi, Anis; Ahmaidi, Said
2017-07-01
Obese patients show a decline in exercise capacity and diverse degrees of dyspnea in association with mechanical abnormalities, increased ventilatory requirements secondary to the increased metabolic load, and a greater work of breathing. Consequently, obese patients may be particularly predisposed to the development of respiratory muscle fatigue during exercise. The aim of this study was to assess inspiratory muscle performance during incremental exercise in 19 obese male subjects (body mass index 41 ± 6 kg/m 2 ) after aerobic exercise training using the noninvasive, inspiratory muscle tension-time index (T T0.1 ). Measurements performed included anthropometric parameters, lung function assessed by spirometry, rate of perceived breathlessness with the modified Borg dyspnea scale (0-10), breathing pattern, maximal exercise capacity, and inspiratory muscle performance with a breath-by-breath automated exercise metabolic system during an incremental exercise test. T T0.1 was calculated using the equation, T T0.1 = P 0.1 /P Imax × T I /T tot (where P 0.1 represents mouth occlusion pressure, P Imax is maximal inspiratory pressure, and T I /T tot is the duty cycle). At rest, there was no statistically significant difference for spirometric parameters and cardiorespiratory parameters between pre- and post-training. At maximal exercise, the minute ventilation, the rate of exchange ratio, the rate of perceived breathlessness, and the respiratory muscle performance parameters were not significantly different pre- and post-training; in contrast, tidal volume ( P = .037, effect size = 1.51), breathing frequency ( P = .049, effect size = 0.97), power output ( P = .048, effect size = 0.79), peak oxygen uptake ( P = .02, effect size = 0.92) were significantly higher after training. At comparable work load, training induces lower minute ventilation, mouth occlusion pressure, ratio of occlusion pressure to maximal inspiratory pressure, T T0.1 , and rate of perceived breathlessness. Aerobic exercise at ventilatory threshold can induce significant improvement in respiratory muscle strength, maximal exercise capacity, and inspiratory muscle performance and decreased dyspnea perception in obese subjects. Copyright © 2017 by Daedalus Enterprises.
Cortés-Télles, Arturo; Torre-Bouscoulet, Luis; Silva-Cerón, Monica; Mejía-Alfaro, Roberto; Syed, Nafeez; Zavorsky, Gerald S; Guenette, Jordan A
2015-11-01
Despite the close link between asthma and obesity, there are no studies that have evaluated the sensory and physiological responses to exercise in obese asthmatics. We recently demonstrated that normal weight asthmatics with well controlled disease have preserved cardiorespiratory and sensory responses to exercise relative to non-asthmatic controls. However, these similarities may not hold true in patients with combined obesity and asthma. Accordingly, we sought to determine if combined asthma and obesity was associated with deleterious effects on cardiorespiratory fitness, exercise performance, dyspnoea, and physiological responses to exercise. Fourteen well-controlled obese asthmatics and fourteen age-matched normal weight asthmatics performed routine spirometry and underwent an incremental cardiopulmonary cycle test to assess the ventilatory, pulmonary gas exchange, cardiovascular, and sensory responses to exercise. Groups were well matched for age, height, spirometry, and asthma control. Obese asthmatics had a significantly greater body mass index (33 ± 3 vs. 23 ± 1 kg/m(2), p < 0.001) and lower self-reported activity levels by 47 % relative to normal weight asthmatics (p < 0.05). Obese asthmatics had a significantly lower maximal oxygen uptake (VO(2)) (82 ± 14 vs. 92 ± 10 %predicted) and work rate (75 ± 8 vs. 89 ± 13 %predicted) relative to normal weight asthmatics (p < 0.05). The anaerobic threshold occurred at a lower VO(2) in obese asthmatics vs. normal weight asthmatics (54 ± 15 vs. 66 ± 16 %predicted, p < 0.05). Ventilatory responses were superimposed throughout exercise with no evidence of a ventilatory limitation in either group. Cardiovascular responses were normal in both groups. Dyspnoea responses were similar but the obese asthmatics experienced greater leg fatigue ratings at submaximal work rates. In conclusion, obese individuals with well controlled asthma have reduced cardiorespiratory fitness and greater leg fatigue ratings relative to normal weight asthmatics. The relatively reduced cardiorespiratory fitness and exercise performance in obese compared to normal weight asthmatics is most likely driven by their more sedentary lifestyle and resultant deconditioning rather than due to respiratory factors. Copyright © 2015 Elsevier Ltd. All rights reserved.
Jeszka, Jan; Podgórski, Tomasz
2017-01-01
The aim of this study was to verify the effect of beta-hydroxy-beta-methylbutyrate (HMB) supplementation on physical capacity, body composition and the value of biochemical parameters in highly-trained combat sports athletes. Forty-two males highly-trained in combat sports were subjected to 12 weeks of supplementation with HMB and a placebo in a randomized, placebo controlled, double-blind crossover manner. Over the course of the experiment, aerobic and anaerobic capacity was determined, while analyses were conducted on body composition and levels of creatine kinase, lactate dehydrogenase, testosterone, cortisol and lactate. Following HMB supplementation, fat-free mass increased (p = 0.049) with a simultaneous reduction of fat mass (p = 0.016) in comparison to placebo. In turn, after HMB supplementation, the following indicators increased significantly in comparison to the placebo: the time to reach ventilatory threshold (p < 0.0001), threshold load (p = 0.017) and the threshold HR (p < 0.0001), as well as anaerobic peak power (p = 0.005), average power (p = 0.029), maximum speed (p < 0.001) and post-exercise lactate concentrations (p < 0.0001). However, when compared to the placebo, no differences were observed in blood marker levels. The results indicate that supplying HMB promotes advantageous changes in body composition and stimulates an increase in aerobic and anaerobic capacity in combat sports athletes. PMID:28708126
Durkalec-Michalski, Krzysztof; Jeszka, Jan; Podgórski, Tomasz
2017-07-14
The aim of this study was to verify the effect of beta-hydroxy-beta-methylbutyrate (HMB) supplementation on physical capacity, body composition and the value of biochemical parameters in highly-trained combat sports athletes. Forty-two males highly-trained in combat sports were subjected to 12 weeks of supplementation with HMB and a placebo in a randomized, placebo controlled, double-blind crossover manner. Over the course of the experiment, aerobic and anaerobic capacity was determined, while analyses were conducted on body composition and levels of creatine kinase, lactate dehydrogenase, testosterone, cortisol and lactate. Following HMB supplementation, fat-free mass increased ( p = 0.049) with a simultaneous reduction of fat mass ( p = 0.016) in comparison to placebo. In turn, after HMB supplementation, the following indicators increased significantly in comparison to the placebo: the time to reach ventilatory threshold ( p < 0.0001), threshold load ( p = 0.017) and the threshold HR ( p < 0.0001), as well as anaerobic peak power ( p = 0.005), average power ( p = 0.029), maximum speed ( p < 0.001) and post-exercise lactate concentrations ( p < 0.0001). However, when compared to the placebo, no differences were observed in blood marker levels. The results indicate that supplying HMB promotes advantageous changes in body composition and stimulates an increase in aerobic and anaerobic capacity in combat sports athletes.
Bernhardt, Vipa; Mitchell, Gordon S.; Lee, Won Y.; Babb, Tony G.
2016-01-01
Background The ventilatory response to exercise can be transiently adjusted in response to environmentally (e.g., breathing apparatus) or physiologically altered conditions (e.g., respiratory disease), maintaining constant relative arterial PCO2 regulation from rest to exercise (Mitchell and Babb, 2006); this augmentation is called short-term modulation (STM) of the exercise ventilatory response. Obesity and/or obstructive sleep apnea could affect the exercise ventilatory response and the capacity for STM due to chronically increased mechanical and/or ventilatory loads on the respiratory system, and/or recurrent (chronic) intermittent hypoxia experienced during sleep. We hypothesized that: 1) the exercise ventilatory response is augmented in obese OSA patients compared with obese non-OSA adults, and 2) the capacity for STM with added dead space is diminished in obese OSA patients. Methods Nine obese adults with OSA (age: 39 ± 6 yr, BMI: 40 ± 5 kg/m2, AHI: 25 ± 24 events/hr [range 6–73], mean ± SD) and 8 obese adults without OSA (age: 38 ± 10 yr, BMI: 37 ± 6 kg/m2, AHI: 1 ± 2) completed three, 20-min bouts of constant-load submaximal cycling exercise (8 min rest, 6 min at 10 and 30 W) with or without added external dead space (200 or 400 ml; 20 min rest between bouts). Steady-state measurements were made of ventilation (V̇E), oxygen consumption (V̇O2), carbon dioxide production (V̇CO2), and end-tidal PCO2 (PETCO2). The exercise ventilatory response was defined as the slope of the V̇E-V̇CO2 relationship (ΔV̇E/ΔV̇CO2). Results In control (i.e. no added dead space), the exercise ventilatory response was not significantly different between non-OSA and OSA groups (ΔV̇E/ΔV̇CO2 slope: 30.5 ± 4.2 vs 30.5 ± 3.8, p > 0.05); PETCO2 regulation from rest to exercise did not differ between groups (p > 0.05). In trials with added external dead space, ΔV̇E/ΔV̇CO2 increased with increased dead space (p < 0.05) and the PETCO2 change from rest to exercise remained small (<2 mmHg) in both groups, demonstrating STM. There were no significant differences between groups. Conclusions Contrary to our hypotheses: 1) the exercise ventilatory response is not increased in obese OSA patients compared with obese non-OSA adults, and 2) the capacity for STM with added dead space is preserved in obese OSA and non-OSA adults. PMID:27840272
Yokokawa, Miki; Desjardins, Benoit; Crawford, Thomas; Good, Eric; Morady, Fred; Bogun, Frank
2013-01-08
The purpose of this study was to assess the determinants of ventricular tachycardia (VT) recurrence in patients who underwent VT ablation for post-infarction VT. The factors that predict recurrence of VT after catheter ablation in patients with prior infarctions are not well described. Catheter ablation was performed in 98 consecutive patients (88 males [90%]; mean age 67 ± 10 years; ejection fraction 27 ± 13%) with post-infarction VT. Electrograms from the implantable cardioverter-defibrillator were analyzed, and VTs were classified as clinical, nonclinical, or new clinical. A total of 725 VTs were induced during the ablation procedure. All VTs were targeted. In 76 patients, 105 clinical VTs were inducible. Critical sites were identified with entrainment mapping and pace-mapping (≥10 of 12 matching leads) for 75 of 105 clinical VTs (71%) and for 278 of 620 nonclinical VTs (45%). Post-ablation, the clinical VT was not inducible in any patient, and all VTs were rendered noninducible in 63% of the patients. Over a mean follow-up period of 35 ± 23 months, 65 of 98 patients (66%) had no recurrent VTs and 33 (34%) had VT recurrence. A new VT occurred in 26 of 33 patients (79%), and a prior clinical VT recurred in 7 patients (21%). Patients with recurrent VT had a larger scar area as assessed by electroanatomic mapping compared with patients without recurrent VTs (93 ± 40 cm(2) vs. 69 ± 30 cm(2); p = 0.002). In patients with repeat procedures, the majority of inducible VTs for which a critical area could be identified were at a distance of 6 ± 3 mm to the prior ablation lesions. Patients with recurrent VTs have a larger scar as assessed by electroanatomic mapping. Most recurrent VTs were new, and the majority of these VTs were mapped to the vicinity of prior ablation lesions in patients with repeat procedures. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Highly symmetric D-brane-anti-D-brane effective actions
NASA Astrophysics Data System (ADS)
Hatefi, Ehsan
2017-09-01
The entire S-matrix elements of four, five and six point functions of D-brane-anti D-brane system are explored. To deal with symmetries of string amplitudes as well as their all order α ' corrections we first address a four point function of one closed string Ramond-Ramond (RR) and two real tachyons on the world volume of brane-anti brane system. We then focus on symmetries of string theory as well as universal tachyon expansion to achieve both string and effective field theory of an RR and three tachyons where the complete algebraic analysis for the whole S-matrix < {V}_{C^{-1}}{V}_{T^{-1}}{V}_{T^0}{V}_{T^0}> was also revealed. Lastly, we employ all the conformal field theory techniques to < {V}_{C^{-1}}{V}_{T^{-1}}{V}_{T^0}{V}_{T^0}{V}_{T^0}> , working out with symmetries of theory and find out the expansion for the amplitude to be able to precisely discover all order singularity structures of D-brane-anti-D-brane effective actions of string theory. Various remarks about the so called generalized Veneziano amplitude and new string couplings are elaborated as well.
2015-01-01
The Virtual Teacher paradigm, a version of the Human Dynamic Clamp (HDC), is introduced into studies of learning patterns of inter-personal coordination. Combining mathematical modeling and experimentation, we investigate how the HDC may be used as a Virtual Teacher (VT) to help humans co-produce and internalize new inter-personal coordination pattern(s). Human learners produced rhythmic finger movements whilst observing a computer-driven avatar, animated by dynamic equations stemming from the well-established Haken-Kelso-Bunz (1985) and Schöner-Kelso (1988) models of coordination. We demonstrate that the VT is successful in shifting the pattern co-produced by the VT-human system toward any value (Experiment 1) and that the VT can help humans learn unstable relative phasing patterns (Experiment 2). Using transfer entropy, we find that information flow from one partner to the other increases when VT-human coordination loses stability. This suggests that variable joint performance may actually facilitate interaction, and in the long run learning. VT appears to be a promising tool for exploring basic learning processes involved in social interaction, unraveling the dynamics of information flow between interacting partners, and providing possible rehabilitation opportunities. PMID:26569608
Lerma, Claudia; Wessel, Niels; Schirdewan, Alexander; Kurths, Jürgen; Glass, Leon
2008-07-01
The objective was to determine the characteristics of heart rate variability and ventricular arrhythmias prior to the onset of ventricular tachycardia (VT) in patients with an implantable cardioverter defibrillator (ICD). Sixty-eight beat-to-beat time series from 13 patients with an ICD were analyzed to quantify heart rate variability and ventricular arrhythmias. The episodes of VT were classified in one of two groups depending on whether the sinus rate in the 1 min preceding the VT was greater or less than 90 beats per minute. In a subset of patients, increased heart rate and reduced heart rate variability was often observed up to 20 min prior to the VT. There was a non-significant trend to higher incidence of premature ventricular complexes (PVCs) before VT compared to control recordings. The patterns of the ventricular arrhythmias were highly heterogeneous among different patients and even within the same patient. Analysis of the changes of heart rate and heart rate variability may have predictive value about the onset of VT in selected patients. The patterns of ventricular arrhythmia could not be used to predict onset of VT in this group of patients.
Kostrubiec, Viviane; Dumas, Guillaume; Zanone, Pier-Giorgio; Kelso, J A Scott
2015-01-01
The Virtual Teacher paradigm, a version of the Human Dynamic Clamp (HDC), is introduced into studies of learning patterns of inter-personal coordination. Combining mathematical modeling and experimentation, we investigate how the HDC may be used as a Virtual Teacher (VT) to help humans co-produce and internalize new inter-personal coordination pattern(s). Human learners produced rhythmic finger movements whilst observing a computer-driven avatar, animated by dynamic equations stemming from the well-established Haken-Kelso-Bunz (1985) and Schöner-Kelso (1988) models of coordination. We demonstrate that the VT is successful in shifting the pattern co-produced by the VT-human system toward any value (Experiment 1) and that the VT can help humans learn unstable relative phasing patterns (Experiment 2). Using transfer entropy, we find that information flow from one partner to the other increases when VT-human coordination loses stability. This suggests that variable joint performance may actually facilitate interaction, and in the long run learning. VT appears to be a promising tool for exploring basic learning processes involved in social interaction, unraveling the dynamics of information flow between interacting partners, and providing possible rehabilitation opportunities.
Ventilatory acclimatization to hypoxia in mice: Methodological considerations.
Ivy, Catherine M; Scott, Graham R
2017-01-01
We examined ventilatory acclimatization to hypoxia (VAH) in CD1 mice, and contrasted results obtained using the barometric method on unrestrained mice with pneumotachography and pulse oximetry on restrained mice. Responses to progressive step reductions in O 2 fraction (21%-8%) were assessed in mice acclimated to normoxia and hypobaric hypoxia (barometric pressure of 60kPa for 6-8 weeks). Hypoxia acclimation increased the hypoxic ventilatory response (primarily by increasing breathing frequency rather than tidal volume), arterial O 2 saturation (Sa O2 ) and heart rate in deep hypoxia, hypoxic chemosensitivity (ventilatory O 2 /CO 2 equivalents versus Sa O2 ), and respiratory water loss, and it blunted the hypoxic depression of metabolism and body temperature. Although some effects of hypoxia acclimation were qualitatively similar between methods, the effects were often greater in magnitude when assessed using pneumotachography. Furthermore, whereas hypoxia acclimation reduced ventilatory O 2 equivalent and increased pulmonary O 2 extraction in barometric experiments, it had the opposite effects in pneumotachography experiments. Our findings highlight the importance of considering the impact of how breathing is measured on the apparent responses to hypoxia. Copyright © 2016 Elsevier B.V. All rights reserved.
Hoffmayer, Kurt S; Bhave, Prashant D; Marcus, Gregory M; James, Cynthia A; Tichnell, Crystal; Chopra, Nagesh; Moxey, Laura; Krahn, Andrew D; Dixit, Sanjay; Stevenson, William; Calkins, Hugh; Badhwar, Nitish; Gerstenfeld, Edward P; Scheinman, Melvin M
2013-04-01
Ventricular arrhythmias in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) and idiopathic ventricular tachycardia (VT) can share a left bundle branch block/inferior axis morphology. We previously reported electrocardiogram characteristics during outflow tract ventricular arrhythmias that helped distinguish VT related to ARVD/C from idiopathic VT. To prospectively validate these criteria. We created a risk score by using a derivation cohort. Two experienced electrophysiologists blinded to the diagnosis prospectively scored patients with VT/premature ventricular contractions (PVCs) with left bundle branch block/inferior axis pattern in a validation cohort of 37 ARVD/C tracings and 49 idiopathic VT tracings. All patients with ARVD/C had their diagnosis confirmed based on the revised task force criteria. Patients with idiopathic VT were selected based on structurally normal hearts with documented right ventricular outflow tract VT successfully treated with ablation. The scoring system provides 3 points for sinus rhythm anterior T-wave inversions in leads V1-V3 and during ventricular arrhythmia: 2 points for QRS duration in lead I≥120 ms, 2 points for QRS notching, and 1 point for precordial transition at lead V5 or later. A score of 5 or greater was able to correctly distinguish ARVD/C from idiopathic VT 93% of the time, with a sensitivity of 84%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 91%. We describe a simple scoring algorithm that uses 12-lead electrocardiogram characteristics to effectively distinguish right ventricular outflow tract arrhythmias originating from patients with ARVD/C versus patients with idiopathic VT. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Tingay, David G; Polglase, Graeme R; Bhatia, Risha; Berry, Clare A; Kopotic, Robert J; Kopotic, Clinton P; Song, Yong; Szyld, Edgardo; Jobe, Alan H; Pillow, J Jane
2015-04-01
Support of the mechanically complex preterm lung needs to facilitate aeration while avoiding ventilation heterogeneities: whether to achieve this gradually or quickly remains unclear. We compared the effect of gradual vs. constant tidal inflations and a pressure-limited sustained inflation (SI) at birth on gas exchange, lung mechanics, gravity-dependent lung volume distribution, and lung injury in 131-day gestation preterm lambs. Lambs were resuscitated with either 1) a 20-s, 40-cmH2O pressure-limited SI (PressSI), 2) a gradual increase in tidal volume (Vt) over 5-min from 3 ml/kg to 7 ml/kg (IncrVt), or 3) 7 ml/kg Vt from birth. All lambs were subsequently ventilated for 15 min with 7 ml/kg Vt with the same end-expiratory pressure. Lung mechanics, gas exchange and spatial distribution of end-expiratory volume (EEV), and tidal ventilation (electrical impedance tomography) were recorded regularly. At 15 min, early mRNA tissue markers of lung injury were assessed. The IncrVt group resulted in greater tissue hysteresivity at 5 min (P = 0.017; two-way ANOVA), higher alveolar-arterial oxygen difference from 10 min (P < 0.01), and least uniform gravity-dependent distribution of EEV. There were no other differences in lung mechanics between groups, and the PressSI and 7 ml/kg Vt groups behaved similarly throughout. EEV was more uniformly distributed, but Vt least so, in the PressSI group. There were no differences in mRNA markers of lung injury. A gradual increase in Vt from birth resulted in less recruitment of the gravity-dependent lung with worse oxygenation. There was no benefit of a SI at birth over mechanical ventilation with 7 ml/kg Vt. Copyright © 2015 the American Physiological Society.
Blouin, D; Topping, C; Moore, S; Stiell, I; Afilalo, M
2001-09-01
The American Heart Association protocols for use of automated external defibrillators (AEDs) recommend that a rhythm analysis be done immediately after each defibrillation attempt. However, shock is often followed by electrical silence or marginally organized electrical activity before ventricular fibrillation (VF) or ventricular tachycardia (VT) recurs. The optimal timing of postshock analysis for identification of recurrent VF/VT is unknown. This study examines the time to recurrence of VF/VT after a defibrillation attempt with AED. Over an 18-month period, all tapes from patients with out-of-hospital cardiac arrest who received shocks at least once with an AED were screened for recurrent VF/VT. All cases come from a single emergency medical services system providing basic life support, defibrillation with AED, and intubation with an esophageal-tracheal twin-lumen airway device (Combitube) for a population of 633,511 individuals. Pediatric and traumatic cases were excluded. When VF/VT recurred within 3 minutes of the defibrillation attempt, rhythm strips were printed and included in the study. Two cardiology fellows, blinded to the study objectives, measured the time from defibrillation to recurrent VF/VT for each strip. Over the study period, 222 tapes from 96 patients met the inclusion criteria. Only 44 (20%) occurrences of VF/VT had recurred within 6 seconds of defibrillation, 162 (73%) at 60 seconds, and 200 (90%) at 90 seconds. Eighty percent of VF/VT recurred more than 6 seconds after defibrillation and were missed when using current American Heart Association AED protocols. Subsequent analysis should be postponed until at least 30 seconds after defibrillation. Performing 30 seconds of chest compressions after defibrillation before subsequent AED rhythm analysis would increase AED identification of VF/VT to 52%.
Kapel, Gijsbert F L; Reichlin, Tobias; Wijnmaalen, Adrianus P; Piers, Sebastiaan R D; Holman, Eduard R; Tedrow, Usha B; Schalij, Martin J; Stevenson, William G; Zeppenfeld, Katja
2015-02-01
Ventricular tachycardia (VT) is an important cause of late morbidity and mortality in repaired congenital heart disease. The substrate often includes anatomic isthmuses that can be transected by radiofrequency catheter ablation similar to isthmus block for atrial flutter. This study evaluates the long-term efficacy of isthmus block for treatment of re-entry VT in adults with repaired congenital heart disease. Thirty-four patients (49±13 years; 74% male) with repaired congenital heart disease who underwent radiofrequency catheter ablation of VT in 2 centers were included. Twenty-two (65%) had a preserved left and right ventricular function. Patients were inducible for 1 (interquartile range, 1-2) VT, median cycle length: 295 ms (interquartile range, 242-346). Ablation aimed to transect anatomic isthmuses containing VT re-entry circuit isthmuses. Procedural success was defined as noninducibility of any VT and transection of the anatomic isthmus and was achieved in 25 (74%) patients. During long-term follow-up (46±29 months), all patients with procedural success (18/25 with internal cardiac defibrillators) were free of VT recurrence but 7 of 18 experienced internal cardiac defibrillator-related complications. One patient with procedural success and depressed cardiac function received an internal cardiac defibrillator shock for ventricular fibrillation. None of the 18 patients (12/18 with internal cardiac defibrillators) with complete success and preserved cardiac function experienced any ventricular arrhythmia. In contrast, VT recurred in 4 of 9 patients without procedural success. Four patients died from nonarrhythmic causes. In patients with repaired congenital heart disease with preserved ventricular function and isthmus-dependent re-entry, VT isthmus ablation can be curative. © 2014 American Heart Association, Inc.
A meta-analysis of manual versus remote magnetic navigation for ventricular tachycardia ablation.
Turagam, Mohit K; Atkins, Donita; Tung, Roderick; Mansour, Moussa; Ruskin, Jeremy; Cheng, Jie; Di Biase, Luigi; Natale, Andrea; Lakkireddy, Dhanunjaya
2017-09-01
There are limited studies on the safety and efficacy of remote magnetic navigation (RMN) versus manual navigation (MAN) in ventricular tachycardia (VT) ablation. A comprehensive literature search was performed using the keywords VT ablation, stereotaxis, RMN and MAN in Pubmed, Ebsco, Web of Science, Cochrane, and Google scholar databases. The analysis included seven studies (one randomized, three prospective observational, and three retrospective) including 779 patients [both structural heart disease (SHD) and idiopathic VT] comparing RMN (N = 433) and MAN (N = 339) in VT ablation. The primary end point of long-term VT recurrence was significantly lower with RMN (OR 0.61, 95% CI 0.44-0.85, p = 0.003) compared with MAN. Other end points of acute procedural success (OR 2.13, 95% CI 1.40-3.23, p = 0.0004) was significantly higher with RMN compared with MAN. Fluoroscopy [mean difference -10.42, 95% CI -12.7 to -8.1, p < 0.0001], procedural time [mean difference -9.79, 95% CI -19.27 to -0.3, p = 0.04] and complications (OR 0.35, 95% CI 0.17-0.74, p = 0.0006) were also significantly lower in RMN when compared with MAN. In a subgroup analysis SHD, there was no significant difference in VT recurrence or acute procedural success with RMN vs. MAN. In idiopathic VT, RMN significantly increased acute procedural success with no difference in VT recurrence. The results demonstrate that RMN is safe and effective when compared with MAN in patients with both SHD and idiopathic VT undergoing catheter ablation. Further prospective studies are needed to further verify the safety and efficacy of RMN.
Kuroki, Kenji; Nogami, Akihiko; Igarashi, Miyako; Masuda, Keita; Kowase, Shinya; Kurosaki, Kenji; Komatsu, Yuki; Naruse, Yoshihisa; Machino, Takeshi; Yamasaki, Hiro; Xu, Dongzhu; Murakoshi, Nobuyuki; Sekiguchi, Yukio; Aonuma, Kazutaka
2018-04-01
Several conducting channels of ventricular tachycardia (VT) can be identified using voltage limit adjustment (VLA) of substrate mapping. However, the sensitivity or specificity to predict a VT isthmus is not high by using VLA alone. This study aimed to evaluate the efficacy of the combined use of VLA and fast-Fourier transform analysis to predict VT isthmuses. VLA and fast-Fourier transform analyses of local ventricular bipolar electrograms during sinus rhythm were performed in 9 postinfarction patients who underwent catheter ablation for a total of 13 monomorphic VTs. Relatively higher voltage areas on an electroanatomical map were defined as high voltage channels (HVCs), and relatively higher fast-Fourier transform areas were defined as high-frequency channels (HFCs). HVCs were classified into full or partial HVCs (the entire or >30% of HVC can be detectable, respectively). Twelve full HVCs were identified in 7 of 9 patients. HFCs were located on 7 of 12 full HVCs. Five VT isthmuses (71%) were included in the 7 full HVC+/HFC+ sites, whereas no VT isthmus was found in the 5 full HVC+/HFC- sites. HFCs were identical to 9 of 16 partial HVCs. Eight VT isthmuses (89%) were included in the 9 partial HVC+/HFC+ sites, whereas no VT isthmus was found in the 7 partial HVC+/HFC- sites. All HVC+/HFC+ sites predicted VT isthmus with a sensitivity of 100% and a specificity of 80%. Combined use of VLA and fast-Fourier transform analysis may be a useful method to detect VT isthmuses. © 2018 American Heart Association, Inc.
Fan, Shengxian; Ni, Xiaodong; Wang, Jian; Zhang, Yongliang; Tao, Shen; Kong, Wencheng; Li, Yousheng; Li, Jieshou
2017-04-01
Previous studies have noticed the high incidence of suboptimal vitamin D (VtD) status and bone loss in short bowel syndrome (SBS) with parenteral nutrition (PN) dependence. However, limited data have focused on adult SBS without PN dependence. Therefore, our objective was to investigate the incidence and risk factors of suboptimal VtD status and bone loss in adult SBS even after weaning off PN. We performed a prospective study of 60 adult patients with SBS. Serum 25-hydroxyvitamin D (25-OHD) was measured by radioimmunoassay. Bone mineral density (BMD) was measured using dual-energy x-ray absorptiometry (DEXA). Medical records and various laboratory parameters were collected in all participants. Suboptimal VtD status was identified in all individuals, including 3 (5.0%) with VtD insufficiency and 57 (95.0%) with VtD deficiency. Residual small bowel length (B, 0.072, P = .001) and duration of SBS (B, -0.066, P = .020) were both significantly correlated with suboptimal VtD levels. Overall, only 2 patients presented a normal BMD; osteopenia and osteoporosis were noted in 41 (68.3%) and 17 (28.3%) individuals, respectively. Low 25-OHD concentration was associated with a decreased BMD (B, 0.065, P = .029). There were no other demographic characteristics or clinical examinations associated with suboptimal VtD levels and bone loss. Suboptimal VtD status and bone loss were common in adult SBS even after weaning off PN. Despite routine oral VtD supplementation, most patients did not achieve satisfactory status. This emphasizes the critical importance of routine surveillance of 25-OHD and BMD, as well as consideration of alternative methods of supplementation after weaning off PN.
Fatemian, Marzieh; Herigstad, Mari; Croft, Quentin P. P.; Formenti, Federico; Cardenas, Rosa; Wheeler, Carly; Smith, Thomas G.; Friedmannova, Maria; Dorrington, Keith L.
2015-01-01
Key points Lung ventilation and pulmonary artery pressure rise progressively in response to 8 h of hypoxia, changes described as ‘acclimatization to hypoxia’. Acclimatization responses differ markedly between humans for unknown reasons.We explored whether the magnitudes of the ventilatory and vascular responses were related, and whether the degree of acclimatization could be predicted by acute measurements of ventilatory and vascular sensitivities.In 80 healthy human volunteers measurements of acclimatization were made before, during, and after a sustained exposure to 8 h of isocapnic hypoxia.No correlation was found between measures of ventilatory and pulmonary vascular acclimatization.The ventilatory chemoreflex sensitivities to acute hypoxia and hypercapnia all increased in proportion to their pre‐acclimatization values following 8 h of hypoxia. The peripheral (rapid) chemoreflex sensitivity to CO2, measured before sustained hypoxia against a background of hyperoxia, was a modest predictor of ventilatory acclimatization to hypoxia. This finding has relevance to predicting human acclimatization to the hypoxia of altitude. Abstract Pulmonary ventilation and pulmonary arterial pressure both rise progressively during the first few hours of human acclimatization to hypoxia. These responses are highly variable between individuals, but the origin of this variability is unknown. Here, we sought to determine whether the variabilities between different measures of response to sustained hypoxia were related, which would suggest a common source of variability. Eighty volunteers individually underwent an 8‐h isocapnic exposure to hypoxia (end‐tidal P O2=55 Torr) in a purpose‐built chamber. Measurements of ventilation and pulmonary artery systolic pressure (PASP) assessed by Doppler echocardiography were made during the exposure. Before and after the exposure, measurements were made of the ventilatory sensitivities to acute isocapnic hypoxia (GpO2) and hyperoxic hypercapnia, the latter divided into peripheral (G pC O2) and central (G cC O2) components. Substantial acclimatization was observed in both ventilation and PASP, the latter being 40% greater in women than men. No correlation was found between the magnitudes of pulmonary ventilatory and pulmonary vascular responses. For GpO2, G pC O2 and G cC O2, but not the sensitivity of PASP to acute hypoxia, the magnitude of the increase during acclimatization was proportional to the pre‐acclimatization value. Additionally, the change in GpO2 during acclimatization to hypoxia correlated well with most other measures of ventilatory acclimatization. Of the initial measurements prior to sustained hypoxia, only G pC O2 predicted the subsequent rise in ventilation and change in GpO2 during acclimatization. We conclude that the magnitudes of the ventilatory and pulmonary vascular responses to sustained hypoxia are predominantly determined by different factors and that the initial G pC O2 is a modest predictor of ventilatory acclimatization. PMID:25907672
Kermorgant, Marc; Lancien, Frédéric; Mimassi, Nagi; Tyler, Charles R; Le Mével, Jean-Claude
2014-09-01
Fluoxetine (FLX) is a selective serotonin (5-HT) reuptake inhibitor present in the aquatic environment which is known to bioconcentrate in the brains of exposed fish. FLX acts as a disruptor of various neuroendocrine functions in the brain, but nothing is known about the possible consequence of FLX exposure on the cardio-ventilatory system in fish. Here we undertook to investigate the central actions of FLX on ventilatory and cardiovascular function in unanesthetized rainbow trout (Oncorhynchus mykiss). Intracerebroventricular (ICV) injection of FLX (dosed between 5 and 25 μg) resulted in a significantly elevated total ventilation (VTOT), with a maximum hyperventilation of +176% (at a dose of 25μg) compared with vehicle injected controls. This increase was due to an increase in ventilatory amplitude (VAMP: +126%) with minor effects on ventilatory frequency. The highest dose of FLX (25 μg) produced a significant increase in mean dorsal aortic blood pressure (PDA: +20%) without effects on heart rate (ƒH). In comparison, intra-arterial injections of FLX (500-2,500 μg) had no effect on ventilation but the highest doses increased both PDA and ƒH. The ICV and IA cardio-ventilatory effects of FLX were very similar to those previously observed following injections of 5-HT, indicating that FLX probably acts via stimulating endogenous 5-HT activity through inhibition of 5-HT transporter(s). Our results demonstrate for the first time in fish that FLX administered within the brain exerts potent stimulatory effects on ventilation and blood pressure increase. The doses of FLX given to fish in our study are higher than the brain concentrations of FLX in fish that result from acute exposure to FLX through the water. Nonetheless, our results indicate possible disrupting action of long term exposure to FLX discharged into the environment on central target sites sensitive to 5-HT involved in cardio-ventilatory control. Copyright © 2013 Elsevier Inc. All rights reserved.
Tamburús, Nayara Y; Kunz, Vandeni C; Salviati, Mariana R; Castello Simões, Viviane; Catai, Aparecida M; Da Silva, Ester
2016-02-01
Exercise training has been an essential component of cardiac rehabilitation. However, it is not known if interval training (IT) based on the ventilatory anaerobic threshold (VAT) could be effective in improving aerobic functional capacity and metabolic profile in patients without or with coronary artery disease (CAD). To investigate the effects of an IT program, based-intensity between 70-110% of workload reached at the VAT, on the aerobic functional capacity and metabolic profile of patients with and without CAD. Randomized controlled trial. Outpatients from a cardiac rehabilitation. A sample was composed of 32 patients with CAD (CAD group) and 32 patients without CAD (noCAD group) that were randomized into a trained or control groups. Submaximal cardiopulmonary exercise test on the cycle ergometer and blood samples were realized at baseline and post 16 weeks of IT program. The cardiorespiratory variables were obtained at the VAT level. Trained groups (CAD-T, N.=15; noCAD-T, N.=15) underwent a supervised three-week session IT program (30-40 minutes each exercise session, at the intensity workloads equivalent to %VAT [70-110%]) for 16 weeks. After 16 weeks of IT program, there were a significant increase of VO(2VAT) and workload in the trained groups (P<0.05), while in the control groups VO(2VAT) and heart rate decreased (P<0.05). Body mass and body index mass decreased in trained groups (P<0.05), and low-density lipoprotein increased only in noCAD group after 16 weeks (P<0.05). The magnitude of the improvement in VO(2VAT) was related to VO(2VAT) (r=-0.57, P<0.05) and workload (r=-0.52, P<0.05) at baseline. The IT program prescribed with intensities based on VAT improved the aerobic functional capacity and decreased body mass and body index mass loss in patients with and without CAD. IT program based on VAT provides new possibilities for cardiac rehabilitation in relation to individualized exercise prescription of the interval training.
Fong, Shirley S M; Ng, Shamay S M; Cheng, Yoyo T Y; Wong, Janet Y H; Yu, Esther Y T; Chow, Gary C C; Chak, Yvonne T C; Chan, Ivy K Y; Zhang, Joni; Macfarlane, Duncan; Chung, Louisa M Y
2016-01-01
Objectives. To evaluate the effects of Ving Tsun (VT) martial art training on the upper extremity muscle strength and eye-hand coordination of middle-aged and older adults. Methods. This study used a nonequivalent pretest-posttest control group design. Forty-two community-dwelling healthy adults participated in the study; 24 (mean age ± SD = 68.5 ± 6.7 years) underwent VT training for 4 weeks (a supervised VT session twice a week, plus daily home practice), and 18 (mean age ± SD = 72.0 ± 6.7 years) received no VT training and acted as controls. Shoulder and elbow isometric muscle strength and eye-hand coordination were evaluated using the Lafayette Manual Muscle Test System and a computerized finger-pointing test, respectively. Results. Elbow extensor peak force increased by 13.9% (P = 0.007) in the VT group and the time to reach peak force decreased (9.9%) differentially in the VT group compared to the control group (P = 0.033). For the eye-hand coordination assessment outcomes, reaction time increased by 2.9% in the VT group and decreased by 5.3% in the control group (P = 0.002). Conclusions. Four weeks of VT training could improve elbow extensor isometric peak force and the time to reach peak force but not eye-hand coordination in community-dwelling middle-aged and older adults.
Márton, Virág; Zádori, János; Kozinszky, Zoltan; Keresztúri, Attila
2016-11-01
To evaluate whether vanishing twin (VT) pregnancies achieved by in vitro fertilization and intracytoplasmic sperm injection (IVF-ICSI) had a more adverse perinatal outcome than those after natural conception. Longitudinal, retrospective cohort study. Tertiary university hospital. Three hundred and six (78 after IVF-ICSI and 228 after natural conception) VT pregnancies over a 22-year period, with VT cases matched to primarily singleton controls. None. Obstetric and neonatal outcome data. The incidence of VT was statistically significantly higher after natural conception (18.2% of twins) than after IVF-ICSI (12.6% of twins). The odds of VT in pregnancies complicated with pregestational or gestational diabetes were disproportionally higher in IVF-ICSI cases than in spontaneously conceived VT pregnancies (adjusted odds ratio [AOR]: 0.80 vs. 3.10 and 1.00 vs. 1.07, respectively). Previous induced abortion (AOR 1.34) or second-trimester fetal loss (AOR 3.3) increased the risk of VT pregnancies after spontaneous conception. Gestational diabetes mellitus in both the previous (AOR 5.41) and the present (AOR 2.3) pregnancy as well as chronic maternal diseases (AOR 3.5) and placentation anomalies all represented independent risk factors for VT after IVF-ICSI. Vanishing twin pregnancies had a lower prevalence and a worse perinatal outcome after IVF-ICSI as compared with those of their spontaneously conceived counterparts. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
An open-label study of sodium oxybate (Xyrem®) in spasmodic dysphonia
Rumbach, Anna F.; Blitzer, Andrew; Frucht, Steven J.; Simonyan, Kristina
2016-01-01
Objective Spasmodic dysphonia (SD) is a task-specific laryngeal dystonia that affects speech production. Co-occurring voice tremor (VT) often complicates the diagnosis and clinical management of SD. Treatment of SD and VT is largely limited to botulinum toxin injections into laryngeal musculature; other pharmacological options are not sufficiently developed. Study Design and Methods We conducted an open-label study in 23 SD and 22 SD/VT patients to examine the effects of sodium oxybate (Xyrem®), an oral agent with therapeutic effects similar to those of alcohol in these patients. Blinded randomized analysis of voice and speech samples assessed symptom improvement before and after drug administration. Results Sodium oxybate significantly improved voice symptoms (p = 0.001) primarily by reducing the number of SD-characteristic voice breaks and severity of VT. Sodium oxybate further showed a trend for improving VT symptoms (p = 0.03) in a subset of patients who received successful botulinum toxin injections for the management of their SD symptoms. The drug’s effects were observed approximately 30–40 min after its intake and lasted about 3.5–4 hours. Conclusion Our study demonstrated that sodium oxybate reduced voice symptoms in 82.2% of alcohol-responsive SD patients both with and without co-occurring VT. Our findings suggest that the therapeutic mechanism of sodium oxybate in SD and SD/VT may be linked to that of alcohol and as such sodium oxybate might be beneficial for alcohol-responsive SD and SD/VT patients. PMID:27808415
Ng, Shamay S. M.; Cheng, Yoyo T. Y.; Yu, Esther Y. T.; Chow, Gary C. C.; Chak, Yvonne T. C.; Chan, Ivy K. Y.; Zhang, Joni; Macfarlane, Duncan
2016-01-01
Objectives. To evaluate the effects of Ving Tsun (VT) martial art training on the upper extremity muscle strength and eye-hand coordination of middle-aged and older adults. Methods. This study used a nonequivalent pretest-posttest control group design. Forty-two community-dwelling healthy adults participated in the study; 24 (mean age ± SD = 68.5 ± 6.7 years) underwent VT training for 4 weeks (a supervised VT session twice a week, plus daily home practice), and 18 (mean age ± SD = 72.0 ± 6.7 years) received no VT training and acted as controls. Shoulder and elbow isometric muscle strength and eye-hand coordination were evaluated using the Lafayette Manual Muscle Test System and a computerized finger-pointing test, respectively. Results. Elbow extensor peak force increased by 13.9% (P = 0.007) in the VT group and the time to reach peak force decreased (9.9%) differentially in the VT group compared to the control group (P = 0.033). For the eye-hand coordination assessment outcomes, reaction time increased by 2.9% in the VT group and decreased by 5.3% in the control group (P = 0.002). Conclusions. Four weeks of VT training could improve elbow extensor isometric peak force and the time to reach peak force but not eye-hand coordination in community-dwelling middle-aged and older adults. PMID:27525020
Henderson, Fraser; May, Walter J; Gruber, Ryan B; Young, Alex P; Palmer, Lisa A; Gaston, Benjamin; Lewis, Stephen J
2013-08-01
The systemic administration of morphine affects ventilation via a mixture of central and peripheral actions. The aims of this study were to characterize the ventilatory responses elicited by a low dose of morphine in conscious rats; to determine whether tolerance develops to these responses; and to determine the potential roles of peripheral μ-opioid receptors (μ-ORs) in these responses. Ventilatory parameters were monitored via unrestrained whole-body plethysmography. Conscious male Sprague-Dawley rats received an intravenous injection of vehicle or the peripherally-restricted μ-OR antagonist, naloxone methiodide (NLXmi), and then three successive injections of morphine (1 mg/kg) given 30 min apart. The first injection of morphine in vehicle-treated rats elicited an array of ventilatory excitant (i.e., increases in frequency of breathing, minute volume, respiratory drive, peak inspiratory and expiratory flows, accompanied by decreases in inspiratory time and end inspiratory pause) and inhibitory (i.e., a decrease in tidal volume and an increase in expiratory time) responses. Subsequent injections of morphine elicited progressively and substantially smaller responses. The pattern of ventilatory responses elicited by the first injection of morphine was substantially affected by pretreatment with NLXmi whereas NLXmi minimally affected the development of tolerance to these responses. Low-dose morphine elicits an array of ventilatory excitant and depressant effects in conscious rats that are subject to the development of tolerance. Many of these initial actions of morphine appear to involve activation of peripheral μ-ORs whereas the development of tolerance to these responses does not.
Prisk, G K; Guy, H J; Elliott, A R; Paiva, M; West, J B
1995-02-01
We used multiple-breath N2 washouts (MBNW) to study the inhomogeneity of ventilation in four normal humans (mean age 42.5 yr) before, during, and after 9 days of exposure to microgravity on Spacelab Life Sciences-1. Subjects performed 20-breath MBNW at tidal volumes of approximately 700 ml and 12-breath MBNW at tidal volumes of approximately 1,250 ml. Six indexes of ventilatory inhomogeneity were derived from data from 1) distribution of specific ventilation (SV) from mixed-expired and 2) end-tidal N2, 3) change of slope of N2 washout (semilog plot) with time, 4) change of slope of normalized phase III of successive breaths, 5) anatomic dead space, and 6) Bohr dead space. Significant ventilatory inhomogeneity was seen in the standing position at normal gravity (1 G). When we compared standing 1 G with microgravity, the distributions of SV became slightly narrower, but the difference was not significant. Also, there were no significant changes in the change of slope of the N2 washout, change of normalized phase III slopes, or the anatomic and Bohr dead spaces. By contrast, transition from the standing to supine position in 1 G resulted in significantly broader distributions of SV (P < 0.05) and significantly greater changes in the changes in slope of the N2 washouts (P < 0.001), indicating more ventilatory inhomogeneity in that posture. Thus these techniques can detect relatively small changes in ventilatory inhomogeneity. We conclude that the primary determinants of ventilatory inhomogeneity during tidal breathing in the upright posture are not gravitational in origin.
Ageing and cardiorespiratory response to hypoxia.
Lhuissier, François J; Canouï-Poitrine, Florence; Richalet, Jean-Paul
2012-11-01
The risk of severe altitude-induced diseases is related to ventilatory and cardiac responses to hypoxia and is dependent on sex, age and exercise training status. However, it remains unclear how ageing modifies these physiological adaptations to hypoxia. We assessed the physiological responses to hypoxia with ageing through a cross-sectional 20 year study including 4675 subjects (2789 men, 1886 women; 14-85 years old) and a longitudinal study including 30 subjects explored at a mean 10.4 year interval. The influence of sex, training status and menopause was evaluated. The hypoxia-induced desaturation and the ventilatory and cardiac responses to hypoxia at rest and exercise were measured. In men, ventilatory response to hypoxia increased (P < 0.002), while desaturation was less pronounced (P < 0.001) with ageing. Cardiac response to hypoxia was blunted with ageing in both sexes (P < 0.001). Similar results were found in the longitudinal study, with a decrease in cardiac and an increase in ventilatory response to hypoxia with ageing. These adaptive responses were less pronounced or absent in post-menopausal women (P < 0.01). At exercise, desaturation was greater in trained subjects but cardiac and ventilatory responses to hypoxia were preserved by training, especially in elderly people. In conclusion, respiratory response to hypoxia and blood oxygenation improve with ageing in men while cardiac response is blunted with ageing in both sexes. Training aggravates desaturation at exercise in hypoxia, improves the ventilatory response and limits the ageing-induced blunting of cardiac response to hypoxia. Training limits the negative effects of menopause in cardiorespiratory adaptations to hypoxia.
Functional significance and control of release of pulmonary surfactant in the lizard lung.
Wood, P G; Daniels, C B; Orgeig, S
1995-10-01
The amount of pulmonary surfactant in the lungs of the bearded dragon (Pogona vitticeps) increases with increasing body temperature. This increase coincides with a decrease in lung compliance. The relationship between surfactant and lung compliance and the principal stimuli for surfactant release and composition (temperature, ventilatory pattern, and autonomic neurotransmitters) were investigated. We chose to investigate ventilatory pattern (which causes mechanical deformation of the type II cells) and adrenergic agents, because they are the major stimuli for surfactant release in mammals. To examine the effects of body temperature and ventilatory pattern, isolated lungs were ventilated at either 18 or 37 degrees C at different ventilatory regimens. An isolated perfused lung preparation at 27 degrees C was used to analyze the effects of autonomic neurotransmitters. Ventilatory pattern did not affect surfactant release, composition, or lung compliance at either 18 or 37 degrees C. An increase in temperature increased phospholipid reuptake and disproportionately increased cholesterol degradation/uptake. Epinephrine and acetylcholine stimulated phospholipid but not cholesterol release. Removal of surfactant caused a decrease in compliance, regardless of the experimental temperature. Temperature appears to be the principal determinant of lung compliance in the bearded dragon, acting directly to increase the tone of the smooth muscle. Increasing the ambient temperature may result in greater surfactant turnover by increasing cholesterol reuptake/degradation directly and by increasing circulating epinephrine, thereby indirectly increasing phospholipid secretion. We suggest that changing ventilatory pattern may be inadequate as a mechanism for maintaining surfactant homeostasis, given the discontinuous, highly variable reptilian breathing pattern.
Kupfer, Yizhak; Seneviratne, Chanaka; Chawla, Kabu; Ramachandran, Kavan; Tessler, Sidney
2011-03-01
Pleural effusions occur frequently in patients requiring mechanical ventilatory support. Treatment of the precipitating cause and resolution of the pleural effusion may take considerable time. We retrospectively studied the effect of chest tube drainage of transudative pleural effusions on the liberation of patients from mechanical ventilatory support. Patients in the medical ICU (MICU) at Maimonides Medical Center between January 1, 2009, and October 31, 2009, requiring mechanical ventilatory support with a transudative pleural effusion, were studied retrospectively. They were divided into two groups: standard care and standard care plus chest tube drainage. Chest tubes were placed under ultrasound guidance by trained intensivists. Duration of mechanical ventilatory support was the primary end point. Secondary end points included measures of oxygenation, amount of fluid drained, and complications associated with the chest tube. A total of 168 patients were studied; 88 were treated with standard care and 80 underwent chest tube drainage. Total duration of mechanical ventilatory support was significantly shorter for patients who had chest tube drainage: 3.8±0.5 days vs 6.5±1.1 days for the standard group (P=.03). No differences in oxygenation were noted between the two groups. The average amount of fluid drained was 1,220 mL. No significant complications were caused by chest tube drainage. Chest tube drainage of transudative pleural effusions resulted in more rapid liberation from mechanical ventilatory support. It is a very safe procedure when performed under ultrasound guidance by experienced personnel. ClinicalTrials.gov; Identifier: NCT0114285; URL: www.clinicaltrials.gov.
Ibuprofen Blunts Ventilatory Acclimatization to Sustained Hypoxia in Humans
Basaran, Kemal Erdem; Villongco, Michael; Ho, Baran; Ellis, Erika; Zarndt, Rachel; Antonova, Julie; Hopkins, Susan R.; Powell, Frank L.
2016-01-01
Ventilatory acclimatization to hypoxia is a time-dependent increase in ventilation and the hypoxic ventilatory response (HVR) that involves neural plasticity in both carotid body chemoreceptors and brainstem respiratory centers. The mechanisms of such plasticity are not completely understood but recent animal studies show it can be blocked by administering ibuprofen, a nonsteroidal anti-inflammatory drug, during chronic hypoxia. We tested the hypothesis that ibuprofen would also block the increase in HVR with chronic hypoxia in humans in 15 healthy men and women using a double-blind, placebo controlled, cross-over trial. The isocapnic HVR was measured with standard methods in subjects treated with ibuprofen (400mg every 8 hrs) or placebo for 48 hours at sea level and 48 hours at high altitude (3,800 m). Subjects returned to sea level for at least 30 days prior to repeating the protocol with the opposite treatment. Ibuprofen significantly decreased the HVR after acclimatization to high altitude compared to placebo but it did not affect ventilation or arterial O2 saturation breathing ambient air at high altitude. Hence, compensatory responses prevent hypoventilation with decreased isocapnic ventilatory O2-sensitivity from ibuprofen at this altitude. The effect of ibuprofen to decrease the HVR in humans provides the first experimental evidence that a signaling mechanism described for ventilatory acclimatization to hypoxia in animal models also occurs in people. This establishes a foundation for the future experiments to test the potential role of different mechanisms for neural plasticity and ventilatory acclimatization in humans with chronic hypoxemia from lung disease. PMID:26726885
NASA Technical Reports Server (NTRS)
Prisk, G. Kim; Guy, Harold J. B.; Elliott, Ann R.; Paiva, Manuel; West, John B.
1995-01-01
We used multiple-breath N2 washouts (MBNW) to study the homogeneity of ventilation in four normal humans (mean age 42.5 yr) before, during, and after 9 days of exposure to microgravity on Spacelab Life Sciences-1. Subjects performed 20-breath MBNW at tidal volumes of approximately 700 ml and 12-breath MBNW at tidal volumes of approximately 1,250 ml. Six indexes of ventilatory inhomogeneity were derived from data from (1) distribution of specific ventilation (SV) from mixed-expired and (2) end-tidal N2, (3) change of slope of N2 washout (semilog plot) with time, (4) change of slope of normalized phase III of successive breaths, (5) anatomic lead dead space, and (6) Bohr dead space. Significant ventilatory inhomogeneity was seen in the standing position at normal gravity (1 G). When we compared standing 1 G with microgravity, the distributions of SV became slightly narrower, but the difference was not significant. Also, there were no significant changes in the change of slope of the N2 washout, change of normalized phase III slopes, or the anatomic and Bohr dead spaces. By contrast, transition from the standing to supine position in 1 G resulted in significantly broader distributions of SV and significantly greater changes in the changes in slope of the N2 washouts, indicating more ventilatory inhomogeneity in that posture. Thus these techniques can detect relatively small changes in ventilatory inhomogeneity. We conclude that the primary determinants of ventilatory inhomogeneity during tidal breathing in the upright posture are not gravitational in origin.
Ibuprofen Blunts Ventilatory Acclimatization to Sustained Hypoxia in Humans.
Basaran, Kemal Erdem; Villongco, Michael; Ho, Baran; Ellis, Erika; Zarndt, Rachel; Antonova, Julie; Hopkins, Susan R; Powell, Frank L
2016-01-01
Ventilatory acclimatization to hypoxia is a time-dependent increase in ventilation and the hypoxic ventilatory response (HVR) that involves neural plasticity in both carotid body chemoreceptors and brainstem respiratory centers. The mechanisms of such plasticity are not completely understood but recent animal studies show it can be blocked by administering ibuprofen, a nonsteroidal anti-inflammatory drug, during chronic hypoxia. We tested the hypothesis that ibuprofen would also block the increase in HVR with chronic hypoxia in humans in 15 healthy men and women using a double-blind, placebo controlled, cross-over trial. The isocapnic HVR was measured with standard methods in subjects treated with ibuprofen (400 mg every 8 hrs) or placebo for 48 hours at sea level and 48 hours at high altitude (3,800 m). Subjects returned to sea level for at least 30 days prior to repeating the protocol with the opposite treatment. Ibuprofen significantly decreased the HVR after acclimatization to high altitude compared to placebo but it did not affect ventilation or arterial O2 saturation breathing ambient air at high altitude. Hence, compensatory responses prevent hypoventilation with decreased isocapnic ventilatory O2-sensitivity from ibuprofen at this altitude. The effect of ibuprofen to decrease the HVR in humans provides the first experimental evidence that a signaling mechanism described for ventilatory acclimatization to hypoxia in animal models also occurs in people. This establishes a foundation for the future experiments to test the potential role of different mechanisms for neural plasticity and ventilatory acclimatization in humans with chronic hypoxemia from lung disease.
The effect of endurance training on the ventilatory response to exercise in elite cyclists.
Hoogeveen, A R
2000-05-01
The purpose of this study was to investigate the effects of endurance training on the ventilatory response to acute incremental exercise in elite cyclists. Fifteen male elite cyclists [mean (SD) age 24.3 (3.3) years, height 179 (6) cm, body mass 71.1 (7.6) kg, maximal oxygen consumption (VO2max) 69 (7) ml x min(-1) x kg(-1)] underwent two exercise tests on a cycle ergometer. The first test was assessed in December, 6 weeks before the beginning of the cycling season. The second test was performed in June, in the middle of the season. During this period the subjects were expected to be in a highly endurance-trained state. The ventilatory response was assessed during an incremental exercise test (20 W x min(-1)). Oxygen consumption (VO2), carbon dioxide production (VCO2), minute ventilation (VE), and heart rate (HR) were assessed at the following points during the test: at workloads of 200 W, 250 W, 300 W, 350 W, 400 W and at the subject's maximal workload, at a respiratory exchange ratio (R) of 1, and at the ventilatory threshold (Th(vent)) determined using the V-slope-method. Post-training, the mean (SD) VO2max was increased from the pre-training level of 69 (7) ml x min(-1) x kg(-1) (range 61.4-78.6) to 78 (6) ml x min(-1) x kg(-1) (range 70.5-86.3). The mean post-training VO2 was significantly higher than the pre training value (P < 0.01) at all work rates, at Th(vent) and at R = 1. VO2 was also higher at all work rates except for 200 W and 250 W. VE was significantly higher at Th(vent) and R = 1. Training had no effect on HR at all workloads examined. An explanation for the higher VO2 cost for the same work rate may be that in the endurance-trained state, the adaptation to an exercise stimulus with higher intensity is faster than for the less-trained state. Another explanation may be that at the same work rate, in the less-endurance-trained state power is generated using a significantly higher anaerobic input. The results of this study suggest the following practical recommendations for training management in elite cyclists: (1) the VO2 for a subject at the same work rate may be an indicator of the endurance-trained state (i.e., the higher the VO2, the higher the endurance-trained capacity), and (2) the need for multiple exercise tests for determining the HR at Th(vent) during a cycling season is doubtful since at Th(vent) this parameter does not differ much following endurance training.
A Vowel-Based Method for Vocal Tract Control in Clarinet Pedagogy
ERIC Educational Resources Information Center
González, Darleny; Payri, Blas
2017-01-01
Our review of scientific literature shows that the activity inside the clarinetist's vocal tract (VT) affects pitch and timbre, while also facilitating technical exercises. Clarinetists adapt their VT intuitively and, in some cases, may compensate an inadequate VT configuration through unnecessary pressure, resulting in technical blockage,…
Complete genome analysis of jasmine virus T from Jasminum sambac in China.
Tang, Yajun; Gao, Fangluan; Yang, Zhen; Wu, Zujian; Yang, Liang
2016-07-01
The genome of a potyvirus (isolate JaVT_FZ) recovered from jasmine (Jasminum sambac L.) showing yellow ringspot symptoms in Fuzhou, China, was sequenced. JaVT_FZ is closely related to seven other potyviruses with completely sequenced genomes, with which it shares 66-70 % nucleotide and 52-56 % amino acid sequence identity. However, the coat protein (CP) gene shares 82-92 % nucleotide and 90-97 % amino acid sequence identity with those of two partially sequenced potyviruses, named jasmine potyvirus T (JaVT-jasmine) and jasmine yellow mosaic potyvirus (JaYMV-India), respectively. This suggests that JaVT_FZ, JaVT-jasmine and JaYMV-India should be regarded as members of a single potyvirus species, for which the name "Jasmine virus T" has priority.
NASA Astrophysics Data System (ADS)
Chen, Charlene; Abe, Katsumi; Fung, Tze-Ching; Kumomi, Hideya; Kanicki, Jerzy
2009-03-01
In this paper, we analyze application of amorphous In-Ga-Zn-O thin film transistors (a-InGaZnO TFTs) to current-scaling pixel electrode circuit that could be used for 3-in. quarter video graphics array (QVGA) full color active-matrix organic light-emitting displays (AM-OLEDs). Simulation results, based on a-InGaZnO TFT and OLED experimental data, show that both device sizes and operational voltages can be reduced when compare to the same circuit using hydrogenated amorphous silicon (a-Si:H) TFTs. Moreover, the a-InGaZnO TFT pixel circuit can compensate for the drive TFT threshold voltage variation (ΔVT) within acceptable operating error range.
Baturina, T I; Mironov, A Yu; Vinokur, V M; Baklanov, M R; Strunk, C
2007-12-21
We investigate low-temperature transport properties of thin TiN superconducting films in the vicinity of the disorder-driven superconductor-insulator transition. In a zero magnetic field, we find an extremely sharp separation between superconducting and insulating phases, evidencing a direct superconductor-insulator transition without an intermediate metallic phase. At moderate temperatures, in the insulating films we reveal thermally activated conductivity with the magnetic field-dependent activation energy. At very low temperatures, we observe a zero-conductivity state, which is destroyed at some depinning threshold voltage V{T}. These findings indicate the formation of a distinct collective state of the localized Cooper pairs in the critical region at both sides of the transition.
Sluis-Cremer, G. K.; Walters, L. G.; Sichel, H. S.
1967-01-01
The ventilatory capacity of a random sample of men over the age of 35 years in the town of Carletonville was estimated by the forced expiratory volume and the peak expiratory flow rate. Five hundred and sixty-two persons were working or had worked in gold-mines and 265 had never worked in gold-mines. No difference in ventilatory function was found between the miners and non-miners other than that due to the excess of chronic bronchitis in miners. PMID:6017134
Edge, Deirdre; O'Halloran, Ken D
2015-01-01
We have previously reported that chronic intermittent hypoxia (CIH), a central feature of human sleep-disordered breathing, causes respiratory instability in sleeping rats (Edge D, Bradford A, O'halloran KD. Adv Exp Med Biol 758:359-363, 2012). Long term facilitation (LTF) of respiratory motor outputs following exposure to episodic, but not sustained, hypoxia has been described. We hypothesized that CIH would enhance ventilatory LTF during sleep. We examined the effects of 3 and 7 days of CIH exposure on the expression of ventilatory LTF in sleeping rats. Adult male Wistar rats were exposed to 20 cycles of normoxia and hypoxia (5 % O(2) at nadir; SaO(2) ~ 80 %) per hour, 8 h per day for 3 or 7 consecutive days (CIH, N = 7 per group). Corresponding sham groups (N = 7 per group) were subjected to alternating cycles of air under identical experimental conditions in parallel. Following gas exposures, breathing during sleep was assessed in unrestrained, unanaesthetized animals using the technique of whole-body plethysmography. Rats were exposed to room air (baseline) and then to an acute IH (AIH) protocol consisting of alternating periods of normoxia (7 min) and hypoxia (FiO(2) 0.1, 5 min) for 10 cycles. Breathing was monitored during the AIH exposure and for 1 h in normoxia following AIH exposure. Baseline ventilation was elevated after 3 but not 7 days of CIH exposure. The hypoxic ventilatory response was equivalent in sham and CIH animals after 3 days but ventilatory responses to repeated hypoxic challenges were significantly blunted following 7 days of CIH. Minute ventilation was significantly elevated following AIH exposure compared to baseline in sham but not in CIH exposed animals. LTF, determined as the % increase in minute ventilation from baseline following AIH exposure, was significantly blunted in CIH exposed rats. In summary, CIH leads to impaired ventilatory responsiveness to AIH. Moreover, CIH blunts ventilatory LTF. The physiological significance of ventilatory LTF is context-dependent but it is reasonable to consider that it can potentially destabilize respiratory control, in view of the potential for LTF to give rise to hypocapnia. CIH-induced blunting of LTF may represent a compensatory mechanism subserving respiratory homeostasis. Our results suggest that CIH-induced increase in apnoea index (Edge D, Bradford A, O'halloran KD. Adv Exp Med Biol 758:359-363, 2012) is not related to enhanced ventilatory LTF. We conclude that the mature adult respiratory system exhibits plasticity and metaplasticity with potential consequences for the control of respiratory homeostasis. Our results may have implications for human sleep apnoea.
Contemporary ventilator management in patients with and at risk of ALI/ARDS.
Chang, Steven Y; Dabbagh, Ousama; Gajic, Ognen; Patrawalla, Amee; Elie, Marie-Carmelle; Talmor, Daniel S; Malhotra, Atul; Adesanya, Adebola; Anderson, Harry L; Blum, James M; Park, Pauline K; Gong, Michelle Ng
2013-04-01
Ventilator practices in patients at risk for acute lung injury (ALI) and ARDS are unclear. We examined factors associated with choice of set tidal volumes (VT), and whether VT < 8 mL/kg predicted body weight (PBW) relates to the development of ALI/ARDS. We performed a secondary analysis of a multicenter cohort of adult subjects at risk of lung injury with and without ALI/ARDS at onset of invasive ventilation. Descriptive statistics were used to describe ventilator practices in specific settings and ALI/ARDS risk groups. Logistic regression analysis was used to determine the factors associated with the use of VT < 8 mL/kg PBW and the relationship of VT to ALI/ARDS development and outcome. Of 829 mechanically ventilated patients, 107 met the criteria for ALI/ARDS at time of intubation, and 161 developed ALI/ARDS after intubation (post-intubation ALI/ARDS). There was significant intercenter variability in initial ventilator settings, and in the incidence of ALI/ARDS and post-intubation ALI/ARDS. The median VT was 7.96 (IQR 7.14-8.94) mL/kg PBW in ALI/ARDS subjects, and 8.45 (IQR 7.50-9.55) mL/kg PBW in subjects without ALI/ARDS (P = .004). VT decreased from 8.40 (IQR 7.38-9.37) mL/kg PBW to 7.97 (IQR 6.90-9.23) mL/kg PBW (P < .001) in those developing post-intubation ALI/ARDS. Among subjects without ALI/ARDS, VT ≥ 8 mL/kg PBW was associated with shorter height and higher body mass index, while subjects with pneumonia were less likely to get ≥ 8 mL/kg PBW. Initial VT ≥ 8 mL/kg PBW was not associated with the post-intubation ALI/ARDS (adjusted odds ratio 1.30, 95% CI 0.74-2.29) or worse outcomes. Post-intubation ALI/ARDS subjects had mortality similar to subjects intubated with ALI/ARDS. Clinicians seem to respond to ALI/ARDS with lower initial VT. Initial VT, however, was not associated with the development of post-intubation ALI/ARDS or other outcomes.
Effects of tidal volume and methacholine on low-frequency total respiratory impedance in dogs.
Lutchen, K R; Jackson, A C
1990-05-01
The frequency dependence of respiratory impedance (Zrs) from 0.125 to 4 Hz (Hantos et al., J. Appl. Physiol. 60: 123-132, 1986) may reflect inhomogeneous parallel time constants or the inherent viscoelastic properties of the respiratory tissues. However, studies on the lung alone or chest wall alone indicate that their impedance features are also dependent on the tidal volumes (VT) of the forced oscillations. The goals of this study were 1) to identify how total Zrs at lower frequencies measured with random noise (RN) compared with that measure with larger VT, 2) to identify how Zrs measured with RN is affected by bronchoconstriction, and 3) to identify the impact of using linear models for analyzing such data. We measured Zrs in six healthy dogs by use of a RN technique from 0.125 to 4 Hz or with a ventilator from 0.125 to 0.75 Hz with VT from 50 to 250 ml. Then methacholine was administered and the RN was repeated. Two linear models were fit to each separate set of data. Both models assume uniform airways leading to viscoelastic tissues. For healthy dogs, the respiratory resistance (Rrs) decreased with frequency, with most of the decrease occurring from 0.125 to 0.375 Hz. Significant VT dependence of Rrs was seen only at these lower frequencies, with Rrs higher as VT decreased. The respiratory compliance (Crs) was dependent on VT in a similar fashion at all frequencies, with Crs decreasing as VT decreased. Both linear models fit the data well at all VT, but the viscoelastic parameters of each model were very sensitive to VT. After methacholine, the minimum Rrs increased as did the total drop with frequency. Nevertheless the same models fit the data well, and both the airways and tissue parameters were altered after methacholine. We conclude that inferences based only on low-frequency Zrs data are problematic because of the effects of VT on such data (and subsequent linear modeling of it) and the apparent inability of such data to differentiate parallel inhomogeneities from normal viscoelastic properties of the respiratory tissues.
Okubo, Masashi; Atkinson, Elizabeth J; Hess, Erik P; White, Roger D
2017-11-01
Mortality from out-of-hospital cardiac arrest (OHCA) is characterized by substantial regional variation. The Institute of Medicine (IOM) recently recommended enhancing the capabilities of EMS systems to improve outcome. In this study, we analyzed the trend in outcome from ventricular fibrillation/pulseless ventricular tachycardia (VF/pVT) OHCA in Rochester, MN. Survival from these forms of arrest is commonly employed as a benchmark of Emergency Medical Services (EMS) system performance. Using a population-based Utstein-style registry in Rochester, MN where a first responder early defibrillation system is utilized, we evaluated outcome from all EMS-treated VF/pVT arrests and the subgroup of bystander-witnessed VF/pVT from 1991 to 2016. Outcome measurement was neurologically intact survival to discharge, defined as Cerebral Performance Category (CPC) 1 or 2. We divided the 26-year study into three periods: 1991-1997, 1998-2008, and 2009-2016, based on initiation of the first responder system of police officers in 1991 and fire-rescue personnel in 1998, and the latter period for comparison with our previous report in 2009. We observed 355 all VF/pVT arrests and 292 bystander-witnessed VF/pVT arrests between 1991 and 2016. In 2009-2016, neurologically intact survival to discharge from overall VF/pVT and bystander-witnessed VF/pVT increased to 53.7% and 65.2%, respectively, compared with 39.5% and 43.4% in 1991-1997. Using multivariable analysis, survival significantly increased in 2009-2016 among all VF/pVT arrests (adjusted OR, 3.10; 95% CI, 1.54-6.40) and bystander-witnessed VF/pVT (adjusted OR, 4.28; 95% CI, 2.01-9.50), compared with those in 1991-1997. We observed a significant improving secular trend in neurologically intact survival from VF/pVT cardiac arrests with a relatively high recent survival rate in this EMS System. Copyright © 2017 Elsevier B.V. All rights reserved.
Becher, Tobias; Schädler, Dirk; Pulletz, Sven; Freitag-Wolf, Sandra; Weiler, Norbert; Frerichs, Inéz
2013-01-01
Introduction Lung-protective ventilation aims at using low tidal volumes (VT) at optimum positive end-expiratory pressures (PEEP). Optimum PEEP should recruit atelectatic lung regions and avoid tidal recruitment and end-inspiratory overinflation. We examined the effect of VT and PEEP on ventilation distribution, regional respiratory system compliance (CRS), and end-expiratory lung volume (EELV) in an animal model of acute lung injury (ALI) and patients with ARDS by using electrical impedance tomography (EIT) with the aim to assess tidal recruitment and overinflation. Methods EIT examinations were performed in 10 anaesthetized pigs with normal lungs ventilated at 5 and 10 ml/kg body weight VT and 5 cmH2O PEEP. After ALI induction, 10 ml/kg VT and 10 cmH2O PEEP were applied. Afterwards, PEEP was set according to the pressure-volume curve. Animals were randomized to either low or high VT ventilation changed after 30 minutes in a crossover design. Ventilation distribution, regional CRS and changes in EELV were analyzed. The same measures were determined in five ARDS patients examined during low and high VT ventilation (6 and 10 (8) ml/kg) at three PEEP levels. Results In healthy animals, high compared to low VT increased CRS and ventilation in dependent lung regions implying tidal recruitment. ALI reduced CRS and EELV in all regions without changing ventilation distribution. Pressure-volume curve-derived PEEP of 21±4 cmH2O (mean±SD) resulted in comparable increase in CRS in dependent and decrease in non-dependent regions at both VT. This implied that tidal recruitment was avoided but end-inspiratory overinflation was present irrespective of VT. In patients, regional CRS differences between low and high VT revealed high degree of tidal recruitment and low overinflation at 3±1 cmH2O PEEP. Tidal recruitment decreased at 10±1 cmH2O and was further reduced at 15±2 cmH2O PEEP. Conclusions Tidal recruitment and end-inspiratory overinflation can be assessed by EIT-based analysis of regional CRS. PMID:23991138
Heldenberg, Eitan; Givon, Adi; Simon, Daniel; Bass, Arie; Almogy, Gidon; Peleg, Kobi
2016-09-01
A high prevalence (10%) of vascular trauma (VT) was previously described in terror-related trauma as compared with non-terror-related trauma (1%), in a civilian setting. No data regarding outcome of VT casualties of improvised explosive device (IED) explosions, in civilian settings, are available. The aim of the current study is to present the prognosis of civilian casualties of IED explosions with and without VT. A retrospective analysis of the Israeli National Trauma Registry was performed. All patients in the registry from September 2000 to December 2005 who were victims of explosions were included. These patients were subdivided into patients with VT (n = 109) and non-VT (NVT) (n = 1,152). Both groups were analyzed according to mechanism of trauma, type and severity of injury, and treatment. Of 1,261 explosion casualties, there were 109 VT victims (8.6%). Patients with VT tended to be more complex, with a higher injury severity score (ISS): 17.4% with ISS 16 to 24 as compared with only 10.5%. In the group of critically injured patients (ISS, 25-75), 51.4% had VT compared with only 15.5% of the NVT patients. As such, a heavy share of hospitals' resources were used-trauma bay admission (62.4%), operating rooms (91.7%), and intensive care unit beds (55.1%). The percentage of VT patients who were admitted for more than 15 days was 2.3 times higher than that observed among the NVT patients. Lower-extremity VT injuries were the most prevalent. Although many resources are being invested in treating this group of patients, their mortality rate is approximately five times more than NVT (22.9% vs. 4.9%). Vascular trauma casualties of IED explosions are more complex and have poorer prognosis. Their higher ISS markedly increases the hospital's resource utilization, and as such, it should be taken into consideration either upon the primary evacuation from the scene or when secondary modulation is needed in order to reduce the burden of the hospitals receiving the casualties. Prognostic/epidemiologic study, level V.
Baboi, Loredana; Subtil, Fabien
2016-01-01
Background Turbine-powered ventilators are not only designed for long-term ventilation at home but also for hospital use. It is important to verify their capabilities in delivering fraction of oxygen in air (FIO2) and tidal volume (VT). Methods We assessed the FIO2 accuracy and the VT delivery in four home care ventilators (HCV) on the bench. The four HCV were Astral 150, Elisée 150, Monnal T50 and Trilogy 200 HCV, which were connected to a lung model (ASL 5000). For assessing FIO2 accuracy, lung model was set to mimic an obstructive lung and HCV were set in volume controlled mode (VC). They supplied with air, 3 or 15 L/min oxygen and FIO2 was measured by using a ventilator tester (Citrex H4TM). For the VT accuracy, the lung model was set in a way to mimic three adult configurations (normal, obstructive, or restrictive respiratory disorder) and one pediatric configuration. Each HCV was set in VC. Two VT (300 and 500 mL) in adult lung configuration and one 50 mL VT in pediatric lung configuration, at two positive end expiratory pressures 5 and 10 cmH2O, were tested. VT accuracy was measured as volume error (the relative difference between set and measured VT). Statistical analysis was performed by suing one-factor ANOVA with a Bonferroni correction for multiple tests. Results For Astral 150, Elisée 150, Monnal T50 and Trilogy 200, FIO2 averaged 99.2%, 93.7%, 86.3%, and 62.1%, respectively, at 15 L/min oxygen supplementation rate (P<0.001). Volume error was 0.5%±0%, −38%±0%, −9%±0%, −29%±0% and −36%±0% for pediatric lung condition (P<0.001). In adult lung configurations, Monnal T50 systematically over delivered VT and Trilogy 150 was sensitive to lung configuration when VT was set to 300 mL at either positive end-expiratory pressure (PEEP). Conclusions HCV are different in terms of FIO2 efficiency and VT delivery. PMID:28149559
Accurate analytical modeling of junctionless DG-MOSFET by green's function approach
NASA Astrophysics Data System (ADS)
Nandi, Ashutosh; Pandey, Nilesh
2017-11-01
An accurate analytical model of Junctionless double gate MOSFET (JL-DG-MOSFET) in the subthreshold regime of operation is developed in this work using green's function approach. The approach considers 2-D mixed boundary conditions and multi-zone techniques to provide an exact analytical solution to 2-D Poisson's equation. The Fourier coefficients are calculated correctly to derive the potential equations that are further used to model the channel current and subthreshold slope of the device. The threshold voltage roll-off is computed from parallel shifts of Ids-Vgs curves between the long channel and short-channel devices. It is observed that the green's function approach of solving 2-D Poisson's equation in both oxide and silicon region can accurately predict channel potential, subthreshold current (Isub), threshold voltage (Vt) roll-off and subthreshold slope (SS) of both long & short channel devices designed with different doping concentrations and higher as well as lower tsi/tox ratio. All the analytical model results are verified through comparisons with TCAD Sentaurus simulation results. It is observed that the model matches quite well with TCAD device simulations.
Validating Lung Models Using the ASL 5000 Breathing Simulator.
Dexter, Amanda; McNinch, Neil; Kaznoch, Destiny; Volsko, Teresa A
2018-04-01
This study sought to validate pediatric models with normal and altered pulmonary mechanics. PubMed and CINAHL databases were searched for studies directly measuring pulmonary mechanics of healthy infants and children, infants with severe bronchopulmonary dysplasia and neuromuscular disease. The ASL 5000 was used to construct models using tidal volume (VT), inspiratory time (TI), respiratory rate, resistance, compliance, and esophageal pressure gleaned from literature. Data were collected for a 1-minute period and repeated three times for each model. t tests compared modeled data with data abstracted from the literature. Repeated measures analyses evaluated model performance over multiple iterations. Statistical significance was established at a P value of less than 0.05. Maximum differences of means (experimental iteration mean - clinical standard mean) for TI and VT are the following: term infant without lung disease (TI = 0.09 s, VT = 0.29 mL), severe bronchopulmonary dysplasia (TI = 0.08 s, VT = 0.17 mL), child without lung disease (TI = 0.10 s, VT = 0.17 mL), and child with neuromuscular disease (TI = 0.09 s, VT = 0.57 mL). One-sample testing demonstrated statistically significant differences between clinical controls and VT and TI values produced by the ASL 5000 for each iteration and model (P < 0.01). The greatest magnitude of differences was negligible (VT < 1.6%, TI = 18%) and not clinically relevant. Inconsistencies occurred with the models constructed on the ASL 5000. It was deemed accurate for the study purposes. It is therefore essential to test models and evaluate magnitude of differences before use.
An open-label study of sodium oxybate in Spasmodic dysphonia.
Rumbach, Anna F; Blitzer, Andrew; Frucht, Steven J; Simonyan, Kristina
2017-06-01
Spasmodic dysphonia (SD) is a task-specific laryngeal dystonia that affects speech production. Co-occurring voice tremor (VT) often complicates the diagnosis and clinical management of SD. Treatment of SD and VT is largely limited to botulinum toxin injections into laryngeal musculature; other pharmacological options are not sufficiently developed. Open-label study. We conducted an open-label study in 23 SD and 22 SD/VT patients to examine the effects of sodium oxybate (Xyrem), an oral agent with therapeutic effects similar to those of alcohol in these patients. Blinded randomized analysis of voice and speech samples assessed symptom improvement before and after drug administration. Sodium oxybate significantly improved voice symptoms (P = .001) primarily by reducing the number of SD-characteristic voice breaks and severity of VT. Sodium oxybate further showed a trend for improving VT symptoms (P = .03) in a subset of patients who received successful botulinum toxin injections for the management of their SD symptoms. The drug's effects were observed approximately 30 to 40 minutes after its intake and lasted about 3.5 to 4 hours. Our study demonstrated that sodium oxybate reduced voice symptoms in 82.2% of alcohol-responsive SD patients both with and without co-occurring VT. Our findings suggest that the therapeutic mechanism of sodium oxybate in SD and SD/VT may be linked to that of alcohol, and as such, sodium oxybate might be beneficial for alcohol-responsive SD and SD/VT patients. 4 Laryngoscope, 127:1402-1407, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Running economy : the forgotten factor in elite performance.
Foster, Carl; Lucia, Alejandro
2007-01-01
Running performance depends on maximal oxygen uptake (VO(2max)), the ability to sustain a high percentage of VO(2max) for an extended period of time and running economy. Running economy has been studied relatively less than the other factors. Running economy, measured as steady state oxygen uptake (VO(2)) at intensities below the ventilatory threshold is the standard method. Extrapolation to a common running speed (268 m/min) or as the VO(2) required to run a kilometer is the standard method of assessment. Individuals of East African origin may be systematically more economical, although a smaller body size and a thinner lower leg may be the primary factors. Strategies for improving running economy remain to be developed, although it appears that high intensity running may be a common element acting to improve economy.
Yan, D; Zhou, H R; Brooks, K H; Pestka, J J
1997-09-26
Dietary exposure to vomitoxin (VT) results in hyperelevated serum IgA and IgA nephropathy in mice. To assess the possible role of cytokines in this IgA dysregulation, the effects of a single oral exposure in B6C3F1 male mice to 0, 5 or 25 mg/kg BW VT on production of IgA and cytokines in Peyer's patch (PP) and spleen cell cultures were evaluated. IgA levels were increased significantly in PP cell cultures prepared from mice at 2 or 24 h after oral exposure to VT and subsequently stimulated with phorbol myristate acetate (PMA) and ionomycin (ION) or with lipopolysaccharide (LPS). Significant effects on IgA production were not observed in spleen cell cultures. Since cytokines such as IL-2, IL-4, IL-5 and IL-6 have been shown to promote IgA production, the effect of the same VT exposure regimen on secretion of these mediators was determined in PP and spleen cultures. Supernatant IL-2 and IL-4 levels were unaffected by the prior treatment of animals with VT. In contrast, IL-5 levels were increased significantly in 7-day PP cell cultures obtained 2 h after VT exposure both with and without PMA + ION exposure but not in other cultures. IL-6 levels were increased significantly in LPS-treated cultures prepared from PP at 2 and 24 h following exposure to VT. IL-6 levels were also elevated significantly in both PMA + ION or LPS treated cultures from spleen isolated at 2 h but not 24 h post VT exposure. To determine whether IL-5 or IL-6 play a role in IgA hyperelevation in vitro, PP and spleen cells from mice obtained 2 h after exposure to 25 mg/kg VT were cultured in the presence of neutralizing cytokine antibodies (Abs) and IgA production was monitored. Consistent with IL-5's previously documented role in IgA production, anti-IL-5 decreased IgA levels to background in cultures of both control and VT-exposed PP or spleen cells in the presence of either PMA + ION or LPS. Similar results were seen with addition of anti-IL-6. IgA levels were decreased to a lesser extent in PP cells cultured with LPS and in spleen cells cultured with PMA + ION from VT-exposed mice to which anti-IL-2 Ab was added. Thus, the potential for enhanced IgA production exists in lymphocytes as early as 2 h and as late as 24 h after a single oral exposure to VT and this may be related to the increased capacity to secrete helper cytokines of T cell and macrophage origin. Taken together, the results suggest that the superinduction of cytokine expression may, in part, be responsible for upregulation of IgA secretion in mice exposed orally to VT.
Criner, Gerard J.; Belt, Patricia; Sternberg, Alice L.; Mosenifar, Zab; Make, Barry J.; Utz, James P.; Sciurba, Frank
2009-01-01
Background: The National Emphysema Treatment Trial studied lung volume reduction surgery (LVRS) for its effects on gas exchange, breathing pattern, and dyspnea during exercise in severe emphysema. Methods: Exercise testing was performed at baseline, and 6, 12, and 24 months. Minute ventilation (V̇e), tidal volume (Vt), carbon dioxide output (V̇co2), dyspnea rating, and workload were recorded at rest, 3 min of unloaded pedaling, and maximum exercise. Pao2, Paco2, pH, fraction of expired carbon dioxide, and bicarbonate were also collected in some subjects at these time points and each minute of testing. There were 1,218 patients enrolled in the study (mean [± SD] age, 66.6 ± 6.1 years; mean, 61%; mean FEV1, 0.77 ± 0.24 L), with 238 patients participating in this substudy (mean age, 66.1 ± 6.8 years; mean, 67%; mean FEV1, 0.78 ± 0.25 L). Results: At 6 months, LVRS patients had higher maximum V̇e (32.8 vs 29.6 L/min, respectively; p = 0.001), V̇co2, (0.923 vs 0.820 L/min, respectively; p = 0.0003), Vt (1.18 vs 1.07 L, respectively; p = 0.001), heart rate (124 vs 121 beats/min, respectively; p = 0.02), and workload (49.3 vs 45.1 W, respectively; p = 0.04), but less breathlessness (as measured by Borg dyspnea scale score) [4.4 vs 5.2, respectively; p = 0.0001] and exercise ventilatory limitation (49.5% vs 71.9%, respectively; p = 0.001) than medical patients. LVRS patients with upper-lobe emphysema showed a downward shift in Paco2 vs V̇co2 (p = 0.001). During exercise, LVRS patients breathed slower and deeper at 6 months (p = 0.01) and 12 months (p = 0.006), with reduced dead space at 6 months (p = 0.007) and 24 months (p = 0.006). Twelve months after patients underwent LVRS, dyspnea was less in patients with upper-lobe emphysema (p = 0.001) and non–upper-lobe emphysema (p = 0.007). Conclusion: During exercise following LVRS, patients with severe emphysema improve carbon dioxide elimination and dead space, breathe slower and deeper, and report less dyspnea. PMID:19420196
Carson, Kristin Veronica; Smith, Brian James; Brinn, Malcolm Philip; Peters, Matthew J; Fitridge, Robert; Koblar, Simon A; Jannes, Jim; Singh, Kuljit; Veale, Antony J; Goldsworthy, Sharon; Litt, John; Edwards, David; Hnin, Khin Moe; Esterman, Adrian Jeffrey
2014-11-01
Inpatient medical settings offer an opportunistic environment for initiating smoking cessation interventions to patients reflecting on their health. Current evidence has shown the superior efficacy of varenicline tartrate (VT) for smoking cessation compared with other tobacco cessation therapies; however, recent evidence also has highlighted concerns about the safety and tolerability of VT. Given these apprehensions, we aimed to evaluate the safety and effectiveness of VT plus quitline-counseling compared to quitline-counseling alone in the inpatient medical setting. Adult patients (n = 392, 20-75 years) admitted with a smoking-related illnesses to 3 hospitals were randomized to receive either 12 weeks of varenicline tartrate (titrated from 0.5mg daily to 1mg twice daily) plus quitline-counseling (VT+C), (n = 196) or quitline-counseling alone (n = 196). VT was well tolerated in the inpatient setting among subjects admitted with acute smoking-related illnesses (mean age 52.8±2.89 and 53.7±2.77 years in the VT+C and counseling alone groups, respectively). The most common self-reported adverse event during the 12-week treatment phase was nausea (16.3% in the VT+C group compared with 1.5% in the counseling alone group). Thirteen deaths occurred during the study period (n = 6 were in the VT+C arm compared with n = 7 in the counseling alone arm). All of these subjects had known comorbidities or developed underlying comorbidities. VT appears to be a safe and well-tolerated opportunistic treatment for inpatient smokers who have related chronic disease. Based on the proven efficacy of varenicline from outpatient studies and our recent inpatient evidence, we suggest it be considered as part of standard care in the hospital setting. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Oppenheim-Eden, A; Cohen, Y; Weissman, C; Pizov, R
2001-08-01
To assess in vitro the performance of five mechanical ventilators-Siemens 300 and 900C (Siemens-Elma; Solna, Sweden), Puritan Bennett 7200 (Nellcor Puritan Bennett; Pleasanton, CA), Evita 4 (Dragerwerk; Lubeck, Germany), and Bear 1000 (Bear Medical Systems; Riverside CA)-and a bedside sidestream spirometer (Datex CS3 Respiratory Module; Datex-Ohmeda; Helsinki, Finland) during ventilation with helium-oxygen mixtures. In vitro study. ICUs of two university-affiliated hospitals. Each ventilator was connected to 100% helium through compressed air inlets and then tested at three to six different tidal volume (VT) settings using various helium-oxygen concentrations (fraction of inspired oxygen [FIO(2)] of 0.2 to 1.0). FIO(2) and VT were measured with the Datex CS3 spirometer, and VT was validated with a water-displacement spirometer. The Puritan Bennett 7200 ventilator did not function with helium. With the other four ventilators, delivered FIO(2) was lower than the set FIO(2). For the Siemens 300 and 900C ventilators, this difference could be explained by the lack of 21% oxygen when helium was connected to the air supply port, while for the other two ventilators, a nonlinear relation was found. The VT of the Siemens 300 ventilator was independent of helium concentration, while for the other three ventilators, delivered VT was greater than the set VT and was dependent on helium concentration. During ventilation with 80% helium and 20% oxygen, VT increased to 125% of set VT for the Siemens 900C ventilator, and more than doubled for the Evita 4 and Bear 1000 ventilators. Under the same conditions, the Datex CS3 spirometer underestimated the delivered VT by about 33%. At present, no mechanical ventilator is calibrated for use with helium. This investigation offers correction factors for four ventilators for ventilation with helium.
1983-02-01
in ZT position, adjust Rx and VT to give the following conditions simul taneously: a) Vc to be specifiied value * RMS Volts. b) VRX Vz. 3. Record: RX...conditions simultaneously: a) V to be specified value as before.c b) VRX Vc. 2. Record: Rx = Q_ ; VT = ; VR =Vc (Volts). C. CALCULATE VOLTAGE AND...2 _V2 cos 8 = cos (180-,) = VRX V2 . VT 2VRX* V Z =R (cos + isino) = Rz + JWTLZ (OHMS) VT x10 (MILLIAMPERES) E(Rx+Rz)2 + LZ2 2 • =TLz COIL "Q
[Pathophysiology of respiratory muscle weakness].
Windisch, W
2008-03-01
The respiratory system consists of two parts which can be impaired independently from each other, the lungs and the respiratory pump. The latter is a complex system covering different anatomic structures: the breathing centre, the peripheral nervous system, the respiratory muscles, and the thorax. According to this complexity several underlying conditions can cause insufficiency of the respiratory pump, i. e. ventilatory failure. Disturbances of the breathing centre, different neuromuscular disorders, impairments of the mechanics, such as thoracic deformities or hyperinflation, and airway obstruction are example conditions responsible for ventilatory failure. Main characteristic of ventilatory failure is the occurrence of hypercapnia which is in contrast to pulmonary failure where diffusion disturbances typically not cause hypercapnia. Both acute and chronic ventilatory failure presenting with hypercapnia can develop. In acute ventilatory failure respiratory acidosis develops, but in chronic respiratory failure pH is normalized as a consequence of metabolic retention of bicarbonate. However, acute on chronic ventilatory failure can present with a combined picture, i. e. elevated bicarbonate levels, acidosis, and often severe hypercapnia. Clinical signs such as tachypnea, features of the underlying disease or hypercapnia are important diagnostic tools in addition to the measurement of pressures generated by the respiratory muscles. Non-invasive and widely available techniques, such as the assessment of the maximal ins- and expiratory mouth pressures (PImax, PEmax), should be used as screening instruments, but the reliability of these measurements is reduced due to the volitional character of the tests and due to the impossibility to define normal values. Inspiratory pressures can be assessed more accurately and independently from the patients' effort: with or without the insertion of oesophageal and gastric balloon catheters. However, this technique is more invasive and very complex. It is therefore restricted to centres with scientific aims.
77 FR 75837 - Amendment of Time of Designation for Restricted Area R-6501B; Underhill, VT
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-26
... R-6501B; Underhill, VT AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: This action amends the time of designation for restricted area R-6501B, Underhill, VT by adding a... INFORMATION: Background The current time of designation of restricted area R-6501B reads [[Page 75838...
33 CFR 110.8 - Lake Champlain, N.Y. and Vt.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Lake Champlain, N.Y. and Vt. 110... ANCHORAGES ANCHORAGE REGULATIONS Special Anchorage Areas § 110.8 Lake Champlain, N.Y. and Vt. (a) Ticonderoga, N.Y. An area shoreward of a line bearing 312° from Ticonderoga Light to the southeast corner of the...
LIU, QIULI; WONG-RILEY, MARGARET T.T
2013-01-01
In rats, a critical period exists around postnatal day (P) 12-13, when an imbalance between heightened inhibition and suppressed excitation led to a weakened ventilatory and metabolic response to acute hypoxia. An open question was whether the two genders follow the same or different developmental trends throughout the first 3 postnatal weeks and whether the critical period exists in one or both genders. The present large-scale, in-depth ventilatory and metabolic study was undertaken to address this question. Our data indicated that: 1) the ventilatory and metabolic rates in both normoxia and acute hypoxia were comparable between the two genders from P0 to P21; thus, gender was never significant as a main effect; and 2) the age effect was highly significant in all parameters studies for both genders, and both genders exhibited a significantly weakened response to acute hypoxia during the critical period. Thus, the two genders have comparable developmental trends, and the critical period exists in both genders in rats. PMID:23797186
Cheng, H; Wang, L S; Pan, H C; Shoung, H M; Lee, L S
1992-02-01
Electrical stimulation of the phrenic nerve to pace the diaphragm in patients with chronic ventilatory insufficiency has been an established therapeutic modality since William W.L. Glenn first described using radiofrequency signals in 1978 to stimulate the phrenic nerves. Before this event, patients who were ventilator-dependent and thus bedridden because of respiratory paralysis associated with quadriplegia usually anticipated little chance for physical or psychosocial rehabilitation. Two cases of C1-C2 subluxtion with cord injury and chronic ventilatory insufficiency were implanted at VGH-Taipei with diaphragm pacemaker in 1988. Postoperative phrenic nerve stimulation was given according to individual training schedule. One case with total phrenic paralysis received bilateral phrenic nerve stimulation and became weaned from the ventilator 6 months later. The other case with partially active ventilatory function received unilateral phrenic nerve stimulation to compensate the ventilation. However, its final outcome still showed the necessity of a bilateral mode to achieve adequate ventilation irrespective of strenuous training for 2 years.
Alteration by hyperoxia of ventilatory dynamics during sinusoidal work.
Casaburi, R; Stremel, R W; Whipp, B J; Beaver, W L; Wasserman, K
1980-06-01
The effects of hyperoxia on ventilatory and gas exchange dynamics were studied utilizing sinusoidal work rate forcings. Five subjects exercised on 14 occasions on a cycle ergometer for 30 min with a sinusoidally varying work load. Tests were performed at seven frequencies of work load during air or 100% O2 inspiration. From the breath-by-breath responses to these tests, dynamic characteristics were analyzed by extracting the mean level, amplitude of oscillation, and phase lag for each six variables with digital computer techniques. Calculation of the time constant (tau) of the ventilatory responses demonstrated that ventilatory kinetics were slower during hyperoxia than during normoxia (P less than 0.025; avg 1.56 and 1.13 min, respectively). Further, for identical work rate fluctuations, end-tidal CO2 tension fluctuations were increased by hyperpoxia. Ventilation during hyperoxia is slower to respond to variations in the level of metabolically produced CO2, presumably because hyperoxia attenuates carotid body output; the arterial CO2 tension is consequently less tightly regulated.
Volcano-tectonic earthquakes: A new tool for estimating intrusive volumes and forecasting eruptions
NASA Astrophysics Data System (ADS)
White, Randall; McCausland, Wendy
2016-01-01
We present data on 136 high-frequency earthquakes and swarms, termed volcano-tectonic (VT) seismicity, which preceded 111 eruptions at 83 volcanoes, plus data on VT swarms that preceded intrusions at 21 other volcanoes. We find that VT seismicity is usually the earliest reported seismic precursor for eruptions at volcanoes that have been dormant for decades or more, and precedes eruptions of all magma types from basaltic to rhyolitic and all explosivities from VEI 0 to ultraplinian VEI 6 at such previously long-dormant volcanoes. Because large eruptions occur most commonly during resumption of activity at long-dormant volcanoes, VT seismicity is an important precursor for the Earth's most dangerous eruptions. VT seismicity precedes all explosive eruptions of VEI ≥ 5 and most if not all VEI 4 eruptions in our data set. Surprisingly we find that the VT seismicity originates at distal locations on tectonic fault structures at distances of one or two to tens of kilometers laterally from the site of the eventual eruption, and rarely if ever starts beneath the eruption site itself. The distal VT swarms generally occur at depths almost equal to the horizontal distance of the swarm from the summit out to about 15 km distance, beyond which hypocenter depths level out. We summarize several important characteristics of this distal VT seismicity including: swarm-like nature, onset days to years prior to the beginning of magmatic eruptions, peaking of activity at the time of the initial eruption whether phreatic or magmatic, and large non-double couple component to focal mechanisms. Most importantly we show that the intruded magma volume can be simply estimated from the cumulative seismic moment of the VT seismicity from: Log10 V = 0.77 Log ΣMoment - 5.32, with volume, V, in cubic meters and seismic moment in Newton meters. Because the cumulative seismic moment can be approximated from the size of just the few largest events, and is quite insensitive to precise locations, the intruded magma volume can be quickly and easily estimated with few short-period seismic stations. Notable cases in which distal VT events preceded eruptions at long-dormant volcanoes include: Nevado del Ruiz (1984-1985), Pinatubo (1991), Unzen (1989-1995), Soufriere Hills (1995), Shishaldin (1989-1999), Tacana' (1985-1986), Pacaya (1980-1984), Rabaul (1994), and Cotopaxi (2001). Additional cases are recognized at frequently active volcanoes including Popocateptl (2001-2003) and Mauna Loa (1984). We present four case studies (Pinatubo, Soufriere Hills, Unzen, and Tacana') in which we demonstrate the above mentioned VT characteristics prior to eruptions. Using regional data recorded by NEIC, we recognized in near-real time that a huge distal VT swarm was occurring, deduced that a proportionately huge magmatic intrusion was taking place beneath the long dormant Sulu Range, New Britain Island, Papua New Guinea, that it was likely to lead to eruptive activity, and warned Rabaul Volcano Observatory days before a phreatic eruption occurred. This confirms the value of this technique for eruption forecasting. We also present a counter-example where we deduced that a VT swarm at Volcan Cosiguina, Nicaragua, indicated a small intrusion, insufficient to reach the surface and erupt. Finally, we discuss limitations of the method and propose a mechanism by which this distal VT seismicity is triggered by magmatic intrusion.
Spicuzza, Lucia; Bernardi, Luciano; Balsamo, Rossella; Ciancio, Nicola; Polosa, Riccardo; Di Maria, Giuseppe
2006-09-01
The increase in peripheral chemoreflex sensitivity in patients with obstructive sleep apnea (OSA) is associated with activation of autonomic nervous system and hemodynamic responses. Nasal CPAP (nCPAP) is an effective treatment for OSA, but little is known on its effect on chemoreflex sensitivity. To assess the effect of nCPAP treatment or placebo (sham nCPAP) on ventilatory control in patients with OSA. Sleep laboratory of Azienda Ospedaliera Garibaldi. Twenty-five patients with moderate-to-severe OSA. Patients were randomly assigned to either therapeutic nCPAP (use of optimal pressure, n = 15) or sham nCPAP (suboptimal pressure of 1 to 2 cm H2O, n = 10) in a double-blind fashion and treated for 1 month. A rebreathing test to assess ventilatory response to normocapnic hypoxia and normoxic hypercapnia was performed at basal condition and after 1 month of treatment. The use of therapeutic nCPAP or sham nCPAP did not affect daytime percentage of arterial oxygen saturation (SaO2%) or end-tidal P(CO2). The normocapnic hypoxic ventilatory response was reduced after 1 month of treatment with nCPAP (the slope was 1.08 +/- 0.02 L/min/SaO2% at basal condition and 0.53 +/- 0.07 L/min/SaO2% after 1 month of treatment, p = 0.008) [mean +/- SD], but not in patients treated with sham nCPAP (slope, 0.83 +/- 0.09 L/min/SaO2% and 0.85 +/- 0.19 L/min/SaO2% at basal condition and after 1 month, respectively). The normoxic hypercapnic ventilatory response remained unchanged after 1 month in both groups. No changes in ventilatory response to either hypoxia or hypercapnia were observed after a single night of nCPAP treatment. The ventilatory response to hypoxia is reduced during regular treatment, but not after short-term treatment, with nCPAP. Readjusted peripheral oxygen chemosensitivity during nCPAP treatment may be a side effect of both reduced sympathetic activity and increased baroreflex activity, or a possible continuous positive airway pressure-related mechanism leading to a reduced activation of autonomic nervous system per se.
Deacon, Naomi L; McEvoy, R Doug; Stadler, Daniel L; Catcheside, Peter G
2017-09-01
Intermittent hypoxia-induced ventilatory neuroplasticity is likely important in obstructive sleep apnea pathophysiology. Although concomitant CO 2 levels and arousal state critically influence neuroplastic effects of intermittent hypoxia, no studies have investigated intermittent hypercapnic hypoxia effects during sleep in humans. Thus the purpose of this study was to investigate if intermittent hypercapnic hypoxia during sleep induces neuroplasticity (ventilatory long-term facilitation and increased chemoreflex responsiveness) in humans. Twelve healthy males were exposed to intermittent hypercapnic hypoxia (24 × 30 s episodes of 3% CO 2 and 3.0 ± 0.2% O 2 ) and intermittent medical air during sleep after 2 wk washout period in a randomized crossover study design. Minute ventilation, end-tidal CO 2 , O 2 saturation, breath timing, upper airway resistance, and genioglossal and diaphragm electromyograms were examined during 10 min of stable stage 2 sleep preceding gas exposure, during gas and intervening room air periods, and throughout 1 h of room air recovery. There were no significant differences between conditions across time to indicate long-term facilitation of ventilation, genioglossal or diaphragm electromyogram activity, and no change in ventilatory response from the first to last gas exposure to suggest any change in chemoreflex responsiveness. These findings contrast with previous intermittent hypoxia studies without intermittent hypercapnia and suggest that the more relevant gas disturbance stimulus of concomitant intermittent hypercapnia frequently occurring in sleep apnea influences acute neuroplastic effects of intermittent hypoxia. These findings highlight the need for further studies of intermittent hypercapnic hypoxia during sleep to clarify the role of ventilatory neuroplasticity in the pathophysiology of sleep apnea. NEW & NOTEWORTHY Both arousal state and concomitant CO 2 levels are known modulators of the effects of intermittent hypoxia on ventilatory neuroplasticity. This is the first study to investigate the effects of combined intermittent hypercapnic hypoxia during sleep in humans. The lack of neuroplastic effects suggests a need for further studies more closely replicating obstructive sleep apnea to determine the pathophysiological relevance of intermittent hypoxia-induced ventilatory neuroplasticity. Copyright © 2017 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Tomita, Nobuyuki; Nebylov, Alexander V.; Sokolov, Victor V.; Ohkami, Yoshiaki
It might be said that it is common understanding that rocket-powered single stage to orbit (SSTO) aerospace planes will become feasible with near-term technology as described in [1] (Koelle, D. E. Survey and comparison of winged launch vehicle options, ISTS 94-g-11 V 1994) and [2] (Bekey, I. Why SSTO rocket launch vehicles are now feasible and practical, IAF-94-V.1.524 1994). Among two methods of launching aerospace planes into orbit, vertical take-off (VT) and horizontal take-off (HT), it seems that VT takes the lead from HT [1, 2]. The decision for the X-33 program by NASA, also, seems to favor VT. In retrospect, almost all of the launch vehicles in the past have been VT, mainly because VT solved the problem of exit from atmosphere to space. However, broadening the range of requirements for space transportation systems from military to commercial and unmanned to manned seems to favor the need for HT. In this paper, the authors are going to prove that aerospace plane/ekranoplane system, which is a reusable launch vehicle system based on the HT concept, with ekranoplane as a take-off and possibly, landing assist, could be competitive with the VT concept from both technological and economical view points. Ekranoplane is a wing-in-ground-effect craft (WIG), which moves at a speed of approximately 0.5 M, carrying heavy loads above the sea surface. Combination of high initial velocity and high performance tri-propellant engine for aerospace plane makes it possible to configure an aerospace plane which is competitive with VT. Other specific features of HT in comparison with VT are discussed.
Luján, Manel; Sogo, Ana; Pomares, Xavier; Monsó, Eduard; Sales, Bernat; Blanch, Lluís
2013-05-01
New home ventilators are able to provide clinicians data of interest through built-in software. Monitoring of tidal volume (VT) is a key point in the assessment of the efficacy of home mechanical ventilation. To assess the reliability of the VT provided by 5 ventilators in a bench test. Five commercial ventilators from 4 different manufacturers were tested in pressure support mode with the help of a breathing simulator under different conditions of mechanical respiratory pattern, inflation pressure, and intentional leakage. Values provided by the built-in software of each ventilator were compared breath to breath with the VT monitored through an external pneumotachograph. Ten breaths for each condition were compared for every tested situation. All tested ventilators underestimated VT (ranges of -21.7 mL to -83.5 mL, which corresponded to -3.6% to -14.7% of the externally measured VT). A direct relationship between leak and underestimation was found in 4 ventilators, with higher underestimations of the VT when the leakage increased, ranging between -2.27% and -5.42% for each 10 L/min increase in the leakage. A ventilator that included an algorithm that computes the pressure loss through the tube as a function of the flow exiting the ventilator had the minimal effect of leaks on the estimation of VT (0.3%). In 3 ventilators the underestimation was also influenced by mechanical pattern (lower underestimation with restrictive, and higher with obstructive). The inclusion of algorithms that calculate the pressure loss as a function of the flow exiting the ventilator in commercial models may increase the reliability of VT estimation.
Serpa Neto, Ary; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Biehl, Michelle; Binnekade, Jan M; Canet, Jaume; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; Hedenstierna, Göran; Hollmann, Markus W; Jaber, Samir; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Maslow, Andrew D; Memtsoudis, Stavros G; Reis Miranda, Dinis; Moine, Pierre; Ng, Thomas; Paparella, Domenico; Putensen, Christian; Ranieri, Marco; Scavonetto, Federica; Schilling, Thomas; Schmid, Werner; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; Gama de Abreu, Marcelo; Pelosi, Paolo; Schultz, Marcus J
2015-07-01
Recent studies show that intraoperative mechanical ventilation using low tidal volumes (VT) can prevent postoperative pulmonary complications (PPCs). The aim of this individual patient data meta-analysis is to evaluate the individual associations between VT size and positive end-expiratory pressure (PEEP) level and occurrence of PPC. Randomized controlled trials comparing protective ventilation (low VT with or without high levels of PEEP) and conventional ventilation (high VT with low PEEP) in patients undergoing general surgery. The primary outcome was development of PPC. Predefined prognostic factors were tested using multivariate logistic regression. Fifteen randomized controlled trials were included (2,127 patients). There were 97 cases of PPC in 1,118 patients (8.7%) assigned to protective ventilation and 148 cases in 1,009 patients (14.7%) assigned to conventional ventilation (adjusted relative risk, 0.64; 95% CI, 0.46 to 0.88; P < 0.01). There were 85 cases of PPC in 957 patients (8.9%) assigned to ventilation with low VT and high PEEP levels and 63 cases in 525 patients (12%) assigned to ventilation with low VT and low PEEP levels (adjusted relative risk, 0.93; 95% CI, 0.64 to 1.37; P = 0.72). A dose-response relationship was found between the appearance of PPC and VT size (R2 = 0.39) but not between the appearance of PPC and PEEP level (R2 = 0.08). These data support the beneficial effects of ventilation with use of low VT in patients undergoing surgery. Further trials are necessary to define the role of intraoperative higher PEEP to prevent PPC during nonopen abdominal surgery.
Neumann, Roland P; Pillow, Jane J; Thamrin, Cindy; Larcombe, Alexander N; Hall, Graham L; Schulzke, Sven M
2015-01-01
Ventilated preterm infant lungs are vulnerable to overdistension and underinflation. The optimal ventilator-delivered tidal volume (VT) in these infants is unknown and may depend on the extent of alveolarisation at birth. We aimed to calculate respiratory dead space (VD) from the molar mass (MM) signal of an ultrasonic flowmeter (VD,MM) in very preterm infants on volume-targeted ventilation (VT target, 4-5 ml/kg) and to study the association between gestational age (GA) and VD,MM-to-VT ratio (VD,MM/VT), alveolar tidal volume (VA) and alveolar minute volume (AMV). This was a single-centre, prospective, observational, cohort study in a neonatal intensive care unit. Tidal breathing analysis was performed in ventilated very preterm infants (GA range 23-32 weeks) on day 1 of life. Valid measurements were obtained in 43/51 (87%) infants. Tidal breathing variables were analysed using multivariable linear regression. VD,MM/VT was negatively associated with GA after adjusting for birth weight Z score (p < 0.001, R(2) = 0.26). This association was primarily influenced by the appliance dead space. Despite similar VT/kg and VA/kg across all studied infants, respiratory rate and AMV/kg increased with GA. VD,app rather than anatomical VD is the major factor influencing increased VD,MM/VT at a younger GA. A volume guarantee setting of 4-5 ml/kg in the Dräger Babylog® 8000 plus ventilator may be inappropriate as a universal target across the GA range of 23-32 weeks. Differences between measured and set VT and the dependence of this difference on GA require further investigation. © 2014 S. Karger AG, Basel.
Electrocardiographic characteristics of left ventricular outflow tract tachycardia.
Hachiya, H; Aonuma, K; Yamauchi, Y; Harada, T; Igawa, M; Nogami, A; Iesaka, Y; Hiroe, M; Marumo, F
2000-11-01
Catheter ablation of idiopathic left ventricular outflow tract tachycardia (LVOT-VT) is rare because a safe ablation technique at this site has not been described, and serious complications may occur. This study compared the QRS morphology of LVOT-VT with that of idiopathic right ventricular outflow tract tachycardia. A comparison was made between the electrocardiographic characteristics of LVOT-VT originating from the supravalvular region of a coronary cusp (Supra-Ao group) with those of LVOT-VT originating from the infravalvular endocardial region of a coronary cusp of the aortic valve within the LV (Infra-Ao group). After precise mapping of the right ventricle, left ventricle, pulmonary artery, coronary cusps, and proximal portion of the anterior interventricular vein, there were 17 patients in whom VT was thought to be located at the LVOT by both activation and pace mapping. They were divided between a Supra-Ao group (n = 8), and an Infra-Ao group (n = 9). Analysis of the 12-lead electrocardiogram (ECG) revealed an S wave in lead I in all 17 patients. A precordial R wave transition was also observed at V1 or V2 in 16 patients (94%). In 7 of 8 patients (88%) with Supra-Ao LVOT-VT, no S wave was observed in either V5 or V6. In contrast, an Rs pattern was observed in both V5 and V6, or in V6 only, in 100% of the patients with Infra-Ao LVOT-VT. A LVOT-VT should be suspected when the ECG shows an S wave in lead I and an R/S ratio greater than 1 in lead V1 or V2, versus a coronary cusp location if there is no S wave in either lead V5 or V6.
Dongelmans, Dave A; Paulus, Frederique; Veelo, Denise P; Binnekade, Jan M; Vroom, Margreeth B; Schultz, Marcus J
2011-05-01
With adaptive support ventilation, respiratory rate and tidal volume (V(T)) are a function of the Otis least work of breathing formula. We hypothesized that adaptive support ventilation in an open lung ventilator strategy would deliver higher V(T)s to patients with acute lung injury. Patients with acute lung injury were ventilated according to a local guideline advising the use of lower V(T) (6-8 ml/kg predicted body weight), high concentrations of positive end-expiratory pressure, and recruitment maneuvers. Ventilation parameters were recorded when the ventilator was switched to adaptive support ventilation, and after recruitment maneuvers. If V(T) increased more than 8 ml/kg predicted body weight, airway pressure was limited to correct for the rise of V(T). Ten patients with a mean (±SD) Pao(2)/Fio(2) of 171 ± 86 mmHg were included. After a switch from pressure-controlled ventilation to adaptive support ventilation, respiratory rate declined (from 31 ± 5 to 21 ± 6 breaths/min; difference = 10 breaths/min, 95% CI 3-17 breaths/min, P = 0.008) and V(T) increased (from 6.5 ± 0.8 to 9.0 ± 1.6 ml/kg predicted body weight; difference = 2.5 ml, 95% CI 0.4-4.6 ml/kg predicted body weight, P = 0.02). Pressure limitation corrected for the rise of V(T), but minute ventilation declined, forcing the user to switch back to pressure-controlled ventilation. Adaptive support ventilation, compared with pressure-controlled ventilation in an open lung strategy setting, delivers a lower respiratory rate-higher V(T) combination. Pressure limitation does correct for the rise of V(T), but leads to a decline in minute ventilation.
New findings on venous thrombogenesis
Byrnes, James R.; Wolberg, Alisa S.
2017-01-01
Summary Venous thrombosis (VT) is the third most common cause of cardiovascular death worldwide. Complications from VT and pulmonary embolism are the leading cause of lost disability-adjusted life years. Risks include genetic (e.g., non-O blood group, activated protein C resistance, hyperprothrombinemia) and acquired (e.g., age, surgery, cancer, pregnancy, immobilisation, female hormone use) factors. Pathophysiologic mechanisms that promote VT are incompletely understood, but involve abnormalities in blood coagulability, vessel function, and flow (so-called Virchow’s Triad). Epidemiologic studies of humans, animal models, and biochemical and biophysical investigations have revealed contributions from extrinsic, intrinsic, and common pathways of coagulation, endothelial cells, leukocytes, red blood cells, platelets, cell-derived microvesicles, stasis-induced changes in vascular cells, and blood rheology. Knowledge of these mechanisms may yield new therapeutic targets. Characterisation of mechanisms that mediate VT formation and stability, particularly in aging, are needed to advance understanding of VT. PMID:27878206
Idiopathic ventricular tachycardia and fibrillation.
Belhassen, B; Viskin, S
1993-06-01
Important data have recently been added to our understanding of sustained ventricular tachyarrhythmias occurring in the absence of demonstrable heart disease. Idiopathic ventricular tachycardia (VT) is usually of monomorphic configuration and can be classified according to its site of origin as either right monomorphic (70% of all idiopathic VTs) or left monomorphic VT. Several physiopathological types of monomorphic VT can be presently individualized, according to their mode of presentation, their relationship to adrenergic stress, or their response to various drugs. The long-term prognosis is usually good. Idiopathic polymorphic VT is a much rarer type of arrhythmia with a less favorable prognosis. Idiopathic ventricular fibrillation may represent an underestimated cause of sudden cardiac death in ostensibly healty patients. A high incidence of inducibility of sustained polymorphic VT with programmed ventricular stimulation has been found by our group, but not by others. Long-term prognosis on Class IA antiarrhythmic medications that are highly effective at electrophysiologic study appears excellent.
Measurement precision of the anaerobic threshold by means of a portable calorimeter.
Nogueira, Fernando dos Santos; Pompeu, Fernando Augusto Monteiro Sabóia
2010-09-01
Many methods are used for determining the Anaerobic Threshold (AT) by means of sophisticated ergospirometer. To test the AT variation, detected by mathematical models and visual inspection, when low cost ergospirometer is used and intended for clinical application. Seventy nine apparently healthy subjects were volunteers in this study; from these, 57 men. The VO₂(max) and the ventilatory threshold were determined by indirect, open-circuit calorimetry. The electro-enzymatic method was used for analyzing the lactacidemia and direct determination of the Lactate Threshold (LT). The AT was determined by two mathematical methods (MM(RSS) and MM(slope)), based on the gases exchange, and by the log-log visual method, for determining the LT. Two independent investigators determined the AT through visual inspection of three graphs, considering two methods (AT₋(a)= V-slope, EqV; and AT₋(b) = V-slope, EqV and ExCO₂). The data were analyzed by means of parametric statistics for determining the differences between AT₋(a) versus ExCO₂, MM(RSS) and MM(slope); AT-b versus MM(RSS) and MM(slope); and LT versus AT₋(a), AT₋(b), MM(RSS) and MM(slope). The MM(slope) was the only method that presented a significant difference between the AT₋(a) and AT₋(b) (p=0.001), with CV% >15. LT versus MM(slope) did not present significant difference (p=0.274), however, it was observed a high CV (24%). It was concluded that with the low cost equipment, the MM(RSS) and AT₋(a) methods can be used for determining the TAn. The MM(slope) method did not present satisfactory precision to be employed with this equipment.
Nikooie, Roohollah; Gharakhanlo, Reza; Rajabi, Hamid; Bahraminegad, Morteza; Ghafari, Ali
2009-10-01
The purpose of this study was to determine the validity of noninvasive anaerobic threshold (AT) estimation using %SpO2 (arterial oxyhemoglobin saturation) changes and respiratory gas exchanges. Fifteen active, healthy males performed 2 graded exercise tests on a motor-driven treadmill in 2 separated sessions. Respiratory gas exchanges and heart rate (HR), lactate concentration, and %SpO2 were measured continuously throughout the test. Anaerobic threshold was determined based on blood lactate concentration (lactate-AT), %SpO2 changes (%SpO2-AT), respiratory exchange ratio (RER-AT), V-slope method (V-slope-AT), and ventilatory equivalent for O2 (EqO2-AT). Blood lactate measuring was considered as gold standard assessment of AT and was applied to confirm the validity of other noninvasive methods. The mean O2 corresponding to lactate-AT, %SpO2-AT, RER-AT, V-slope -AT, and EqO2-AT were 2176.6 +/- 206.4, 1909.5 +/- 221.4, 2141.2 +/- 245.6, 1933.7 +/- 216.4, and 1975 +/- 232.4, respectively. Intraclass correlation coefficient (ICC) analysis indicates a significant correlation between 4 noninvasive methods and the criterion method. Blond-Altman plots showed the good agreement between O2 corresponding to AT in each method and lactate-AT (95% confidence interval (CI). Our results indicate that a noninvasive and easy procedure of monitoring the %SpO2 is a valid method for estimation of AT. Also, in the present study, the respiratory exchange ratio (RER) method seemed to be the best respiratory index for noninvasive estimation of anaerobic threshold, and the heart rate corresponding to AT predicted by this method can be used by coaches and athletes to define training zones.
Soh, Zu; Matsuno, Motoki; Yoshida, Masayuki; Tsuji, Toshio
2018-04-01
Fear and anxiety in fish are generally evaluated by video-based behavioral analysis. However, it is difficult to distinguish the psychological state of fish exclusively through video analysis, particularly whether the fish are freezing, which represents typical fear behavior, or merely resting. We propose a system that can measure bioelectrical signals called ventilatory signals and simultaneously analyze swimming behavior in real time. Experimental results comparing the behavioral analysis of the proposed system and the camera system showed a low error level with an average absolute position error of 9.75 ± 3.12 mm (about one-third of the body length) and a correlation between swimming speeds of r = 0.93 ± 0.07 (p < 0.01). We also exposed the fish to zebrafish skin extracts containing alarm substances that induce fear and anxiety responses to evaluate their emotional changes. The results confirmed that this solution significantly changed all behavioral and ventilatory signal indices obtained by the proposed system (p < 0.01). By combining the behavioral and ventilatory signal indices, we could detect fear and anxiety with a discrimination rate of 83.3% ± 16.7%. Furthermore, we found that the decreasing fear and anxiety over time could be detected according to the peak frequency of the ventilatory signals, which cannot be measured through video analysis.
Respiration and the generation of rhythmic outputs in insects.
Kammer, A E
1976-07-01
In insects gas exchange may be: 1) entirely passive, when metabolic rate is low; 2) enhanced automatically by muscle contractions that produce movements, e.g., wing movements in flight; or 3) produced by ventilatory movements, particularly of the abdomen. In terrestrial insects such as locusts and cockroaches ventilatory movements are governed by a dominant oscillator in the metathoracic or anterior abdominal ganglion. The dominant oscillator overrides local oscillators in the abdominal ganglia and thus sets the rhythm for the entire abdomen, and it also controls spiracle opening and closing in several thoracic and abdominal segments. This ventilatory control mechanism appears to be different from that generating metachronal rhythms such as occur in the ventilatory and locomotory movements of aquatic arthropods. There are now several examples of rhythms, both ventilatory and locomotory, that can be generated by the central nervous system in the absence of phasic sensory feedback, but the mechanism of rhythm production is not known. Studies of ganglionic output suggest that neuronal oscillators can produce a range of frequencies and that some oscillators may be employed in more than one function or behavior. The mechanisms by which central oscillators are coupled to the output motorneurons are also not known; large phase changes suggest that in some cases different coupling interneurons are active. Intracellular recordings from identified neurons have begun to clarify the important roles of interneurons in the production of motor patterns.
Benefits of Manometer in Non-Invasive Ventilatory Support.
Lacerda, Rodrigo Silva; de Lima, Fernando Cesar Anastácio; Bastos, Leonardo Pereira; Fardin Vinco, Anderson; Schneider, Felipe Britto Azevedo; Luduvico Coelho, Yves; Fernandes, Heitor Gomes Costa; Bacalhau, João Marcus Ramos; Bermudes, Igor Matheus Simonelli; da Silva, Claudinei Ferreira; da Silva, Luiza Paterlini; Pezato, Rogério
2017-12-01
Introduction Effective ventilation during cardiopulmonary resuscitation (CPR) is essential to reduce morbidity and mortality rates in cardiac arrest. Hyperventilation during CPR reduces the efficiency of compressions and coronary perfusion. Problem How could ventilation in CPR be optimized? The objective of this study was to evaluate non-invasive ventilator support using different devices. The study compares the regularity and intensity of non-invasive ventilation during simulated, conventional CPR and ventilatory support using three distinct ventilation devices: a standard manual resuscitator, with and without airway pressure manometer, and an automatic transport ventilator. Student's t-test was used to evaluate statistical differences between groups. P values <.05 were regarded as significant. Peak inspiratory pressure during ventilatory support and CPR was significantly increased in the group with manual resuscitator without manometer when compared with the manual resuscitator with manometer support (MS) group or automatic ventilator (AV) group. The study recommends for ventilatory support the use of a manual resuscitator equipped with MS or AVs, due to the risk of reduction in coronary perfusion pressure and iatrogenic thoracic injury during hyperventilation found using manual resuscitator without manometer. Lacerda RS , de Lima FCA , Bastos LP , Vinco AF , Schneider FBA , Coelho YL , Fernandes HGC , Bacalhau JMR , Bermudes IMS , da Silva CF , da Silva LP , Pezato R . Benefits of manometer in non-invasive ventilatory support. Prehosp Disaster Med. 2017;32(6):615-620.
Trends and Issues in Vocational Training in the Republic of China on Taiwan.
ERIC Educational Resources Information Center
Lee, Lung-Sheng
Vocational training (VT) in Taiwan is categorized into public training (PT) and enterprise training (ET). PT is provided primarily by 13 PT centers, and ET is provided in various ways. A review of the state of VT in Taiwan established that VT policies and practices are being influenced by increasing emphasis on the knowledge-based economy and…
Wu, Florence TH; Lee, Christina R; Bogdanovic, Elena; Prodeus, Aaron; Gariépy, Jean; Kerbel, Robert S
2015-01-01
Angiopoietin-1 (Ang1) activation of Tie2 receptors on endothelial cells (ECs) reduces adhesion by tumor cells (TCs) and limits junctional permeability to TC diapedesis. We hypothesized that systemic therapy with Vasculotide (VT)—a purported Ang1 mimetic, Tie2 agonist—can reduce the extravasation of potentially metastatic circulating TCs by similarly stabilizing the host vasculature. In vitro, VT and Ang1 treatments impeded endothelial hypermeability and the transendothelial migration of MDA-MB-231•LM2-4 (breast), HT29 (colon), or SN12 (renal) cancer cells to varying degrees. In mice, VT treatment inhibited the transit of TCs through the pulmonary endothelium, but not the hepatic or lymphatic endothelium. In the in vivo LM2-4 model, VT monotherapy had no effect on primary tumors, but significantly delayed distant metastatic dissemination to the lungs. In the post-surgical adjuvant treatment setting, VT therapeutically complemented sunitinib therapy, an anti-angiogenic tyrosine kinase inhibitor which limited the local growth of residual disease. Unexpectedly, detailed investigations into the putative mechanism of action of VT revealed no evidence of Tie2 agonism or Tie2 binding; alternative mechanisms have yet to be determined. PMID:25851538
Ventilatory Responsiveness of Goats with Ablated Carotid Bodies,
1982-06-03
R.A.Gabel, D.E. Leith, and V. Fencl 9. PERFORMING ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT. PROJECT. TASK AREA & WORK UNIT NUMBERS US Army... vestigial ventilatory response to cyanide. These findings persisted throughout 10 the 5 months of our observation, in contrast with the observations of
Huang, Yu-Ling; Liu, Yen-Wenn; Huang, Yu-Jou; Chiou, Wen-Fei
2013-01-01
Vitis thunbergii is used in Taiwan as a botanical supplement for inflammatory bone diseases. This study aims to examine its direct effect on bone metabolism. Three-month-old female mice were randomly divided into ovariectomized control (OVX), sham operated (SHAM), and ovariectomy treated with either 17β-estradiol or a special ingredient (VtR) fractionated from an ethanol extract of V. thunbergii started two weeks after ovariectomy. VtR treatment for 8 weeks significantly ameliorated the deterioration of bone mineral density and reversed all the ovariectomy-induced changes in μ-CT parameters. The antiosteoporotic effect of VtR accompanied decrease in serum levels of C-terminal telopeptides of type I collagen (CTx), interleukin-7, and ration of RANKL/osteoprotegerin (OPG) but rise in osteocalcin concentration. Sparse calcified microarchitecture and less alkaline-phosphatase- (ALP-) positive cells were observed at the femur and vertebral sites in OVX mice while VtR remarkably restored such variation. HPLC analysis showed (+)-vitisin-A, (−)-vitisin-B, and ampelopsin C predominated in VtR. Both (−)-vitisin B and ampelopsin C increased ALP activity and bone nodule formation in cultured osteoblasts. Instead of stimulating osteoblastogenesis, (+)-vitisin A dramatically repressed osteoclasts differentiation and bone resorption. The results suggested VtR composed of diverse components to reciprocally drive osteoblastogenesis and interdict osteoclastogenesis may serve as a potential botanic drug for osteoporosis therapy. PMID:23662133
Witt, Emitt C; Wronkiewicz, David J; Pavlowsky, Robert T; Shi, Honglan
2013-09-01
Fugitive dust from 18 unsurfaced roadways in Missouri were sampled using a novel cyclonic fugitive dust collector that was designed to obtain suspended bulk samples for analysis. The samples were analyzed for trace metals, Fe and Al, particle sizes, and mineralogy to characterize the similarities and differences between roadways. Thirteen roads were located in the Viburnum Trend (VT) mining district, where there has been a history of contaminant metal loading of local soils; while the remaining five roads were located southwest of the VT district in a similar rural setting, but without any mining or industrial process that might contribute to trace metal enrichment. Comparison of these two groups shows that trace metal concentration is higher for dusts collected in the VT district. Lead is the dominant trace metal found in VT district dusts representing on average 79% of the total trace metal concentration, and was found moderately to strongly enriched relative to unsurfaced roads in the non-VT area. Fugitive road dust concentrations calculated for the VT area substantially exceed the 2008 Federal ambient air standard of 0.15μgm(-3) for Pb. The pattern of trace metal contamination in fugitive dust from VT district roads is similar to trace metal concentrations patterns observed for soils measured more than 40years ago indicating that Pb contamination in the region is persistent as a long-term soil contaminant. Published by Elsevier Ltd.
Abdullah, B J J; Mohammad, N; Sangkar, J V; Abd Aziz, Y F; Gan, G G; Goh, K Y; Benedict, I
2005-07-01
The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).
NASA Astrophysics Data System (ADS)
Almendros, J.; Carmona, E.; Jiménez, V.; Díaz-Moreno, A.; Lorenzo, F.
2018-05-01
In September 2014 there was a sharp increase in the seismic activity of the Bransfield Strait, Antarctica. More than 9,000 earthquakes with magnitudes up to 4.6 located SE of Livingston Island were detected over a period of 8 months. A few months after the series onset, local seismicity at the nearby (˜35 km) Deception Island volcano increased, displaying enhanced long-period seismicity and several outbursts of volcano-tectonic (VT) earthquakes. Before February 2015, VT earthquakes occurred mainly at 5-20 km SW of Deception Island. In mid-February the numbers and sizes of VT earthquakes escalated, and their locations encompassed the whole volcanic edifice, suggesting a situation of generalized unrest. The activity continued in anomalously high levels at least until May 2015. Given the spatial and temporal coincidence, it is unlikely that the Livingston series and the Deception VT swarm were unrelated. We propose that the Livingston series may have produced a triggering effect on Deception Island volcano. Dynamic stresses associated to the seismic swarm may have induced overpressure in the unstable volcanic system, leading to a magmatic intrusion that may in turn have triggered the VT swarm. Alternatively, both the Livingston earthquakes and the VT swarm could be consequences of a magmatic intrusion at Deception Island. The Livingston series would be an example of precursory distal VT swarm, which seems to be a common feature preceding volcanic eruptions and magma intrusions in long-dormant volcanoes.
[Lung protective ventilation. Ventilatory modes and ventilator parameters].
Schädler, Dirk; Weiler, Norbert
2008-06-01
Mechanical ventilation has a considerable potential for injuring the lung tissue. Therefore, attention has to be paid to the proper choice of ventilatory mode and settings to secure lung-protective ventilation whenever possible. Such ventilator strategy should account for low tidal volume ventilation (6 ml/kg PBW), limited plateau pressure (30 to 35 cm H2O) and positive end-expiratory pressure (PEEP). It is unclear whether pressure controlled or volume controlled ventilation with square flow profile is beneficial. The adjustment of inspiration and expiration time should consider the actual breathing mechanics and anticipate the generation of intrinsic PEEP. Ventilatory modes with the possibility of supporting spontaneous breathing should be used as soon as possible.
Mendoza, Michelle; Gelinas, Deborah F; Moore, Dan H; Miller, Robert G
2007-04-01
Using a retrospective analysis of 161 patients with amyotrophic lateral sclerosis (ALS) from the Western ALS study group (WALS) database, the sensitivity of maximal inspiratory pressure (MIP)< -60 cm H(2)O and forced vital capacity (FVC)< 50% as US Medicare thresholds for initiating non-invasive ventilation (NIV) were compared. Sixty-five per cent of patients at enrollment met the MIP criterion, compared with only 8% of patients who met the FVC criterion. There were no cases in which FVC< 50% antedated MIP< -60 cm H(2)O. The longitudinal data showed that patients reached the MIP criterion 4 to 6.5 months earlier than the FVC criterion. For patients with clinical signs and symptoms needing treatment with NIV, a MIP< -60 cm H(2)O allows US clinicians to obtain non-invasive ventilatory support for patients earlier than if using the FVC criterion alone.
Performance of Digital Communications over Selective Fading Channels.
1983-09-01
and we assume that the "" receiver has compensated for the mean path delay td . Equivalently, we let d - : - 0 in order to establish a time reference...Pv dl g(V v( 4bd 2G2 E 211v/T2 (3.37) N0 4’. .4 which implies that iv is the key parameter in determining the signal-to-noise ratio for single-pulse...in (4.8) are defined by R-77 7777 7777,077 7-7.7 70 jnht(-b )/ Td Kv(h,bi,:) = , v(t) v(t-4) e h i dt (4.10a) and R=hbit v(t) v(t+T-4) e•j uh t (1- b
Kawamura, Iwanari; Fukamizu, Seiji; Miyazawa, Satoshi; Hojo, Rintaro; Ito, Fusahiko; Watanabe, Masazumi; Nishizaki, Mitsuhiro; Sakurada, Harumizu; Hiraoka, Masayasu
2018-02-01
A 58-year-old man with dilated cardiomyopathy was admitted with heart failure. He had a history of two catheter ablation procedures for ventricular tachycardia (VT) originating from the intraventricular septum (IVS). Before dual valve replacement (DVR), he suffered a VT storm. An electrophysiological study revealed an extended low-voltage area at the IVS with the exit of the induced VT at the anterior side. Radiofrequency application was performed at the VT exit as a landmark for surgical cryoablation (SA). During the DVR, SA was performed at the IVS using this landmark. After SA, the patient had no ventricular tachyarrhythmia.
Better GGA and meta-GGA Functionals: VT84, meta-VMT, meta-VT84
NASA Astrophysics Data System (ADS)
Vela, Alberto; Martin Del Campo, J.; Gazquez, J. L.; Trickey, S. B.
2011-03-01
The goal of fast DFT calculations on large families of highly complicated systems (e.g. large clusters, biomolecules) implicitly conflicts with the heavy emphasis of recent years on inclusion of exact exchange. In response we have worked on improving non-empirical GGA X functionals. Here we report extension of our VMT GGA functional (J. Chem. Phys. 130 244103 (2009)) to satisfy a relevant asymptotic constraint, yielding the VT{84} X functional. With the PBE C functional, VT{84} gives about 10% improvement over VMT in energetics on the G3 223 molecule set. At the meta-GGA level of complexity, we have both meta-VMT and meta-{84}. The former is about 10% better on the G3 set than the TPSS meta-GGA, while meta-VT{84} gives roughly 10% further improvement over meta-VMT. Details of these assessments, including improvements in chemical shifts, will be presented. SBT acknowledges US DOE Grant DE-SC0002139.
Ventricular tachycardia in post-myocardial infarction patients. Results of surgical therapy.
Viganò, M; Martinelli, L; Salerno, J A; Minzioni, G; Chimienti, M; Graffigna, A; Goggi, C; Klersy, C; Montemartini, C
1986-05-01
This report addresses the problems related to surgical treatment of post-infarction ventricular tachycardia (VT) and is based on a 5 year experience of 36 consecutive patients. In every case the arrhythmia was unresponsive to pharmacological therapy. All patients were operated on after the completion of a diagnostic protocol including preoperative endocardial, intra-operative epi-endocardial mapping, the latter performed automatically when possible. Surgical techniques were: classical Guiraudon's encircling endocardial ventriculotomy (EEV); partial EEV, endocardial resection (ER); cryoablation or a combination of these procedures. The in-hospital mortality (30 days) was 8.3% (3 patients). During the follow-up period (1-68 months), 3 patients (9%) died of cardiac but not VT related causes. Of the survivors, 92% are VT-free. We consider electrophysiologically guided surgery a safe and reliable method for the treatment of post-infarction VT and suggest its more extensive use. We stress the importance of automatic mapping in pleomorphic and non-sustained VT, and the necessity of tailoring the surgical technique to the characteristics of each case.
Enjoji, Yoshihisa; Mizobuchi, Masahiro; Muranishi, Hiromi; Miyamoto, Chinae; Utsunomiya, Makoto; Funatsu, Atsushi; Kobayashi, Tomoko; Nakamura, Shigeru
2009-12-01
Ventricular fibrillation (VF) or ventricular tachycardia (VT) storm is a life-threatening arrhythmia. Antiarrhythmic drugs (AADs) are not necessarily effective to rescue life from such conditions. Catheter ablation (CA) targeting triggering premature ventricular contractions (PVCs) of VF or VT that originates from Purkinje fiber network (PFN) is reported to be effective, especially in idiopathic patients. However, in condition of acute coronary syndrome (ACS), the efficacy of CA is not well understood. To clarify the usefulness of CA as an alternative way to AADs, we performed CA in four patients with VF or VT storm. The Purkinje potential was seen just before the myocardial ventricular wave during sinus rhythm that became more prominent and double components during the initiating PVC at the targeted area. Following CA, spontaneous episodes of VF or VT were no longer observed. CA is an efficacious way to bail out PFN-related VF or VT storm even in ACS.
This study examines the cardiac and ventilatory effects of sequential exposure to nitrogen dioxide and then ozone. The data show that mice exposed to both gases have increased arrhythmia and breathing changes not observed in the other groups. Although the mechanisms underlying ai...
De Smet, Hilde R; Bersten, Andrew D; Barr, Heather A; Doyle, Ian R
2007-12-01
Low tidal volume (V(T)) ventilation strategies may be associated with permissive hypercapnia, which has been shown by ex vivo and in vivo studies to have protective effects. We hypothesized that hypercapnic acidosis may be synergistic with low V(T) ventilation; therefore, we studied the effects of hypercapnia and V(T) on unstimulated and lipopolysaccharide-stimulated isolated perfused lungs. Isolated perfused rat lungs were ventilated for 2 hours with low (7 mL/kg) or moderately high (20 mL/kg) V(T) and 5% or 20% CO(2), with lipopolysaccharide or saline added to the perfusate. Hypercapnia resulted in reduced pulmonary edema, lung stiffness, tumor necrosis factor alpha (TNF-alpha) and interleukin 6 (IL-6) in the lavage and perfusate. The moderately high V(T) did not cause lung injury but increased lavage IL-6 and perfusate IL-6 as well as TNF-alpha. Pulmonary edema and respiratory mechanics improved, possibly as a result of a stretch-induced increase in surfactant turnover. Lipopolysaccharide did not induce significant lung injury. We conclude that hypercapnia exerts a protective effect by modulating inflammation, lung mechanics, and edema. The moderately high V(T) used in this study stimulated inflammation but paradoxically improved edema and lung mechanics with an associated increase in surfactant release.
Wu, Florence T H; Lee, Christina R; Bogdanovic, Elena; Prodeus, Aaron; Gariépy, Jean; Kerbel, Robert S
2015-06-01
Angiopoietin-1 (Ang1) activation of Tie2 receptors on endothelial cells (ECs) reduces adhesion by tumor cells (TCs) and limits junctional permeability to TC diapedesis. We hypothesized that systemic therapy with Vasculotide (VT)-a purported Ang1 mimetic, Tie2 agonist-can reduce the extravasation of potentially metastatic circulating TCs by similarly stabilizing the host vasculature. In vitro, VT and Ang1 treatments impeded endothelial hypermeability and the transendothelial migration of MDA-MB-231∙LM2-4 (breast), HT29 (colon), or SN12 (renal) cancer cells to varying degrees. In mice, VT treatment inhibited the transit of TCs through the pulmonary endothelium, but not the hepatic or lymphatic endothelium. In the in vivo LM2-4 model, VT monotherapy had no effect on primary tumors, but significantly delayed distant metastatic dissemination to the lungs. In the post-surgical adjuvant treatment setting, VT therapeutically complemented sunitinib therapy, an anti-angiogenic tyrosine kinase inhibitor which limited the local growth of residual disease. Unexpectedly, detailed investigations into the putative mechanism of action of VT revealed no evidence of Tie2 agonism or Tie2 binding; alternative mechanisms have yet to be determined. © 2015 The Authors. Published under the terms of the CC BY 4.0 license.
Hartas, J; Sriprakash, K S
1999-01-01
Streptococcus pyogenes infection and acute glomerulonephritis (AGN), a non-suppurtave disease, are endemic in the Aboriginal people of the Northern Territory (NT) of Australia. Vir typing, a locus-specific polymerase chain reaction (PCR)-based typing method [Gardiner, Hartas, Currie et al PCR Meth Appl 1995 4: 288-93], has revealed high divergence among the NT streptococcal strains. A total of 76 Vir types (VTs) representing about 95% of the NT isolates were screened for sic, a gene for streptococcal inhibitor of complement function, by PCR and hybridization. This revealed that seven VTs are positive for sic, and there are two classes of the gene: those closely related to sic (CRS) originally described by Akesson, Sjoholm & Bjorck [ J. Biol. Chem. 1996 271: 1081-8] and those distantly related to sic (DRS). Among the CRS-positive VTs, VT16, VT78 and VT91 have emm (gene for M protein) encoding type 1 M protein or related specificity, and VT8 and VT101 contain emm57 or related alleles. Chromosomal location of CRS in emm57 is different from that in emm1 or related strains. The DRS-positive VT18 and VT52 contained emm55 and emm12 respectively, which are phylogenetically related. Strains of S. pyogenes types 1, 12, 55 and 57 are known to be associated with AGN. Restricted distribution of CRS and DRS among the M types historically associated with AGN suggests that these sic alleles may have a role in AGN pathogenesis. Copyright 1999 Academic Press.
Senthilkumar, B; Rajasekaran, R
2017-03-01
Rapid increase in antibiotic resistance has posed a worldwide threat, due to increased mortality, morbidity, and expenditure caused by antibiotic-resistant microbes. Recent development of the antimicrobial peptides like viscotoxin (Vt) has been successfully comprehended as a substitute for classical antibiotics. A structurally stable peptide, Vt can enhance antimicrobial property and can be used for various developmental purposes. Thus, structural stability among the antimicrobial peptides, Vt A1 (3C8P), A2 (1JMN), A3 (1ED0), B (1JMP), and C (1ORL) of Viscus album was computationally analyzed. In specific, the static confirmation of VtA3 showed high number of intramolecular interactions, along with an increase in hydrophobicity than others comparatively. Further, conformational sampling was used to analyze various geometrical parameters such as root mean square deviation, root mean square fluctuation, radius of gyration, and ovality which also revealed the structural stability of VtA3. Moreover, the statistically validated contours of surface area, lipophilicity, and distance constraints of disulfide bonds also supported the priority of VtA3 with respect to stability. Finally, the functional activity of peptides was accessed by computing their free energy of membrane association and membrane interactions, which defined VtA3 as functionally stable. Currently, peptide-based antibiotics and nanoparticles have attracted the pharmaceutical industries for their potential therapeutic applications. Thereby, it is proposed that viscotoxin A3 (1ED0) could be used as a preeminent template for scaffolding potentially efficient antimicrobial peptide-based drugs and nanomaterials in future.
Decreased lung compliance increases preload dynamic tests in a pediatric acute lung injury model.
Erranz, Benjamín; Díaz, Franco; Donoso, Alejandro; Salomón, Tatiana; Carvajal, Cristóbal; Torres, María Fernanda; Cruces, Pablo
2015-01-01
Preload dynamic tests, pulse pressure variation (PPV) and stroke volume variation (SVV) have emerged as powerful tools to predict response to fluid administration. The influence of factors other than preload in dynamic preload test is currently poorly understood in pediatrics. The aim of our study was to assess the effect of tidal volume (VT) on PPV and SVV in the context of normal and reduced lung compliance in a piglet model. Twenty large-white piglets (5.2±0.4kg) were anesthetized, paralyzed and monitored with pulse contour analysis. PPV and SVV were recorded during mechanical ventilation with a VT of 6 and 12mL/kg (low and high VT, respectively), both before and after tracheal instillation of polysorbate 20. Before acute lung injury (ALI) induction, modifications of VT did not significantly change PPV and SVV readings. After ALI, PPV and SVV were significantly greater during ventilation with a high VT compared to a low VT (PPV increased from 8.9±1.2 to 12.4±1.1%, and SVV from 8.5±1.0 to 12.7±1.2%, both P<0.01). This study found that a high VT and reduced lung compliance due to ALI increase preload dynamic tests, with a greater influence of the latter. In subjects with ALI, lung compliance should be considered when interpreting the preload dynamic tests. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.
Eruption Forecasting in Alaska: A Retrospective and Test of the Distal VT Model
NASA Astrophysics Data System (ADS)
Prejean, S. G.; Pesicek, J. D.; Wellik, J.; Cameron, C.; White, R. A.; McCausland, W. A.; Buurman, H.
2015-12-01
United States volcano observatories have successfully forecast most significant US eruptions in the past decade. However, eruptions of some volcanoes remain stubbornly difficult to forecast effectively using seismic data alone. The Alaska Volcano Observatory (AVO) has responded to 28 eruptions from 10 volcanoes since 2005. Eruptions that were not forecast include those of frequently active volcanoes with basaltic-andesite magmas, like Pavlof, Veniaminof, and Okmok volcanoes. In this study we quantify the success rate of eruption forecasting in Alaska and explore common characteristics of eruptions not forecast. In an effort to improve future forecasts, we re-examine seismic data from eruptions and known intrusive episodes in Alaska to test the effectiveness of the distal VT model commonly employed by the USGS-USAID Volcano Disaster Assistance Program (VDAP). In the distal VT model, anomalous brittle failure or volcano-tectonic (VT) earthquake swarms in the shallow crust surrounding the volcano occur as a secondary response to crustal strain induced by magma intrusion. Because the Aleutian volcanic arc is among the most seismically active regions on Earth, distinguishing distal VT earthquake swarms for eruption forecasting purposes from tectonic seismicity unrelated to volcanic processes poses a distinct challenge. In this study, we use a modified beta-statistic to identify pre-eruptive distal VT swarms and establish their statistical significance with respect to long-term background seismicity. This analysis allows us to explore the general applicability of the distal VT model and quantify the likelihood of encountering false positives in eruption forecasting using this model alone.
Effects of Analgesic Use on Inflammation and Hematology in a Murine Model of Venous Thrombosis
Hish, Gerald A; Diaz, Jose A; Hawley, Angela E; Myers, Daniel D; Lester, Patrick A
2014-01-01
Venous thrombosis (VT) is a significant cause of morbidity and mortality in humans. Surgical animal models are crucial in studies investigating the pathogenesis of this disease and evaluating VT therapies. Because inflammation is critical to both the development and resolution of VT, analgesic medications have the potential to adversely affect multiple parameters of interest in VT research. The objective of this study was to determine how several common analgesics affect key variables in a murine ligation model of deep vein thrombosis. Male C57BL/6 mice were randomly assigned to receive either local (bupivacaine) or systemic parenteral analgesia (buprenorphine, tramadol, or carprofen) or 0.9% NaCl (control). All mice underwent laparotomy and ligation of the inferior vena cava, and treatment was continued until euthanasia at 6 or 48 h after surgery. Analysis of harvested tissues and blood included: hematology, thrombus weight, serum and vein-wall cytokines (IL1β, IL6, IL10, TNFα), soluble P-selectin, and vein-wall leukocyte infiltration. Compared with 0.9% NaCl, all of the analgesics affected multiple parameters important to VT research. Carprofen and tramadol affected the most parameters and should not be used in murine models of VT. Although they affected fewer parameters, a single dose of bupivacaine increased thrombus weight at 6 h, and buprenorphine was associated with reduced vein wall macrophages at 48 h. Although we cannot recommend the use of any of the evaluated analgesic dosages in this mouse model of VT, buprenorphine merits additional investigation to ensure the highest level of laboratory animal care and welfare. PMID:25255071