NASA Technical Reports Server (NTRS)
Gebben, V. D.; Webb, J. A., Jr.
1972-01-01
An electronic circuit for processing arterial blood pressure waveform signals is described. The circuit detects blood pressure as the heart pumps blood through the aortic valve and the pressure distribution caused by aortic valve closure. From these measurements, timing signals for use in measuring the left ventricular ejection time is determined, and signals are provided for computer monitoring of the cardiovascular system. Illustrations are given of the circuit and pressure waveforms.
Martina, Jerson R; Westerhof, Berend E; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F M; de Mol, Bas A J M; Lahpor, Jaap R
2014-01-01
Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all <10%). These blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.
Ahrens, T S; Schallom, L
2001-01-01
Techniques to measure pulmonary artery (PA) pressure waveforms include digital measurement, graphic measurement, and freeze-cursor measurement. Previous studies reported the inaccuracy of digital and freeze-cursor measurements. However, many of the previous studies were small and did not thoroughly examine the circumstances of when digital measurements might be inaccurate. To compare digital measurements and graphic measurements of PA and central venous pressure (CVP) waveforms in patients with a variety of respiratory patterns, and to compare digital measurements and graphic measurements of CVPs in patients with abnormal or right ventricular waveforms. A total of 928 patients were enrolled in this study. Waveforms from the PA and CVP were collected from each patient. The monitor pressure value (digital measurement) printed on the recorded waveform was compared with the pressure value obtained by a graphic strip recording and measured by one of the primary investigators (graphic measurement). Digital measurements were found to be inaccurate in measuring waveforms in all respiratory categories and in measuring right ventricular waveforms. PA diastolic values and CVP values were the most inaccurately measured waveforms. Digital errors of more than 4 mm Hg were common. There were instances in which the monitor's digital measurement was substantially different from the graphically measured value. This difference has the potential to mislead interpretation of clinical situations. The monitor's ability to occasionally give digital measurement values similar to the graphic measurements may lead to a false sense of security in clinicians. Because the accuracy of the monitor is inconsistent, the bedside clinician should interpret waveforms through use of a graphic recording rather than rely on the digital measurement on the monitor.
Electronic circuit detects left ventricular ejection events in cardiovascular system
NASA Technical Reports Server (NTRS)
Gebben, V. D.; Webb, J. A., Jr.
1972-01-01
Electronic circuit processes arterial blood pressure waveform to produce discrete signals that coincide with beginning and end of left ventricular ejection. Output signals provide timing signals for computers that monitor cardiovascular systems. Circuit operates reliably for heart rates between 50 and 200 beats per minute.
Noninvasive estimation of assist pressure for direct mechanical ventricular actuation
NASA Astrophysics Data System (ADS)
An, Dawei; Yang, Ming; Gu, Xiaotong; Meng, Fan; Yang, Tianyue; Lin, Shujing
2018-02-01
Direct mechanical ventricular actuation is effective to reestablish the ventricular function with non-blood contact. Due to the energy loss within the driveline of the direct cardiac compression device, it is necessary to acquire the accurate value of assist pressure acting on the heart surface. To avoid myocardial trauma induced by invasive sensors, the noninvasive estimation method is developed and the experimental device is designed to measure the sample data for fitting the estimation models. By examining the goodness of fit numerically and graphically, the polynomial model presents the best behavior among the four alternative models. Meanwhile, to verify the effect of the noninvasive estimation, the simplified lumped parameter model is utilized to calculate the pre-support and the post-support left ventricular pressure. Furthermore, by adjusting the driving pressure beyond the range of the sample data, the assist pressure is estimated with the similar waveform and the post-support left ventricular pressure approaches the value of the adult healthy heart, indicating the good generalization ability of the noninvasive estimation method.
Kuznetsova, Tatiana; Cauwenberghs, Nicholas; Knez, Judita; Thijs, Lutgarde; Liu, Yan-Ping; Gu, Yu-Mei; Staessen, Jan A
2015-04-01
The cardio-renal interaction occurs via hemodynamic and humoral factors. Noninvasive assessment of renal hemodynamics is currently possible by assessment of renal resistive index (RRI) derived from intrarenal Doppler arterial waveforms as ((peak systolic velocity - end-diastolic velocity)/peak systolic velocity). Limited information is available regarding the relationship between RRI and cardiac hemodynamics. We investigated these associations in randomly recruited subjects from a general population. In 171 participants (48.5% women; mean age, 52.2 years), using pulsed wave Doppler, we measured RRI (mean, 0.60) and left ventricular outflow tract (LVOT) and transmitral (E and A) blood flow peak velocities and its velocity time integrals (VTI). Using carotid applanation tonometry, we measured central pulse pressure and arterial stiffness indexes such as augmentation pressure and carotid-femoral pulse wave velocity. In stepwise regression analysis, RRI independently and significantly increased with female sex, age, body weight, brachial pulse pressure, and use of β-blockers, whereas it decreased with body height and mean arterial pressure. In multivariable-adjusted models with central pulse pressure and arterial stiffness indexes as the explanatory variables, we observed a significant and positive correlation of RRI only with central pulse pressure (P < 0.0001). Among the Doppler indexes of left ventricular blood flow, RRI was significantly and positively associated with LVOT and E peak velocities (P ≤ 0.012) and VTIs (P ≤ 0.010). We demonstrated that in unselected subjects RRI was significantly associated with central pulse pressure and left ventricular systolic and diastolic Doppler blood flow indexes. Our findings imply that in addition to the anthropometric characteristics, cardiac hemodynamic factors influence the intrarenal arterial Doppler waveform patterns. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
A LabVIEW model incorporating an open-loop arterial impedance and a closed-loop circulatory system.
Cole, R T; Lucas, C L; Cascio, W E; Johnson, T A
2005-11-01
While numerous computer models exist for the circulatory system, many are limited in scope, contain unwanted features or incorporate complex components specific to unique experimental situations. Our purpose was to develop a basic, yet multifaceted, computer model of the left heart and systemic circulation in LabVIEW having universal appeal without sacrificing crucial physiologic features. The program we developed employs Windkessel-type impedance models in several open-loop configurations and a closed-loop model coupling a lumped impedance and ventricular pressure source. The open-loop impedance models demonstrate afterload effects on arbitrary aortic pressure/flow inputs. The closed-loop model catalogs the major circulatory waveforms with changes in afterload, preload, and left heart properties. Our model provides an avenue for expanding the use of the ventricular equations through closed-loop coupling that includes a basic coronary circuit. Tested values used for the afterload components and the effects of afterload parameter changes on various waveforms are consistent with published data. We conclude that this model offers the ability to alter several circulatory factors and digitally catalog the most salient features of the pressure/flow waveforms employing a user-friendly platform. These features make the model a useful instructional tool for students as well as a simple experimental tool for cardiovascular research.
Heerdt, P M; Pond, C G; Kussman, M K; Triantafillou, A N
1993-01-01
Despite numerous technologic advances in intraoperative monitoring, the only methods routinely available for assessment of right ventricular function in lung transplant recipients are continuous measurement of right heart pressures and intermittent thermodilution determination of cardiac output and ejection fraction. Additional data may now be obtained with transesophageal echocardiography, although this technology is expensive and not widely available and requires diverting attention from a potentially unstable patient for data acquisition and analysis. Recently, a Doppler pulmonary artery catheter was introduced that measures beat-to-beat pulmonary artery blood flow-velocity, cross sectional area, and volume flow. Because of data indicating that acceleration of blood in the pulmonary artery (measured as the first derivative of either the velocity or flow waveform) is a sensitive indicator of right ventricular contractility, we have used waveforms obtained with the catheter for assessment of right ventricular pump function (stroke volume and peak pulmonary artery flow rate) and contractility in heart surgery patients. We report here our experience with this method in two patients undergoing left single lung transplantation.
Kamoi, Shun; Pretty, Christopher; Docherty, Paul; Squire, Dougie; Revie, James; Chiew, Yeong Shiong; Desaive, Thomas; Shaw, Geoffrey M; Chase, J Geoffrey
2014-01-01
Accurate, continuous, left ventricular stroke volume (SV) measurements can convey large amounts of information about patient hemodynamic status and response to therapy. However, direct measurements are highly invasive in clinical practice, and current procedures for estimating SV require specialized devices and significant approximation. This study investigates the accuracy of a three element Windkessel model combined with an aortic pressure waveform to estimate SV. Aortic pressure is separated into two components capturing; 1) resistance and compliance, 2) characteristic impedance. This separation provides model-element relationships enabling SV to be estimated while requiring only one of the three element values to be known or estimated. Beat-to-beat SV estimation was performed using population-representative optimal values for each model element. This method was validated using measured SV data from porcine experiments (N = 3 female Pietrain pigs, 29-37 kg) in which both ventricular volume and aortic pressure waveforms were measured simultaneously. The median difference between measured SV from left ventricle (LV) output and estimated SV was 0.6 ml with a 90% range (5th-95th percentile) -12.4 ml-14.3 ml. During periods when changes in SV were induced, cross correlations in between estimated and measured SV were above R = 0.65 for all cases. The method presented demonstrates that the magnitude and trends of SV can be accurately estimated from pressure waveforms alone, without the need for identification of complex physiological metrics where strength of correlations may vary significantly from patient to patient.
A computer model of the pediatric circulatory system for testing pediatric assist devices.
Giridharan, Guruprasad A; Koenig, Steven C; Mitchell, Michael; Gartner, Mark; Pantalos, George M
2007-01-01
Lumped parameter computer models of the pediatric circulatory systems for 1- and 4-year-olds were developed to predict hemodynamic responses to mechanical circulatory support devices. Model parameters, including resistance, compliance and volume, were adjusted to match hemodynamic pressure and flow waveforms, pressure-volume loops, percent systole, and heart rate of pediatric patients (n = 6) with normal ventricles. Left ventricular failure was modeled by adjusting the time-varying compliance curve of the left heart to produce aortic pressures and cardiac outputs consistent with those observed clinically. Models of pediatric continuous flow (CF) and pulsatile flow (PF) ventricular assist devices (VAD) and intraaortic balloon pump (IABP) were developed and integrated into the heart failure pediatric circulatory system models. Computer simulations were conducted to predict acute hemodynamic responses to PF and CF VAD operating at 50%, 75% and 100% support and 2.5 and 5 ml IABP operating at 1:1 and 1:2 support modes. The computer model of the pediatric circulation matched the human pediatric hemodynamic waveform morphology to within 90% and cardiac function parameters with 95% accuracy. The computer model predicted PF VAD and IABP restore aortic pressure pulsatility and variation in end-systolic and end-diastolic volume, but diminish with increasing CF VAD support.
Pahlevan, Niema M; Rinderknecht, Derek G; Tavallali, Peyman; Razavi, Marianne; Tran, Thao T; Fong, Michael W; Kloner, Robert A; Csete, Marie; Gharib, Morteza
2017-07-01
The study is based on previously reported mathematical analysis of arterial waveform that extracts hidden oscillations in the waveform that we called intrinsic frequencies. The goal of this clinical study was to compare the accuracy of left ventricular ejection fraction derived from intrinsic frequencies noninvasively versus left ventricular ejection fraction obtained with cardiac MRI, the most accurate method for left ventricular ejection fraction measurement. After informed consent, in one visit, subjects underwent cardiac MRI examination and noninvasive capture of a carotid waveform using an iPhone camera (The waveform is captured using a custom app that constructs the waveform from skin displacement images during the cardiac cycle.). The waveform was analyzed using intrinsic frequency algorithm. Outpatient MRI facility. Adults able to undergo MRI were referred by local physicians or self-referred in response to local advertisement and included patients with heart failure with reduced ejection fraction diagnosed by a cardiologist. Standard cardiac MRI sequences were used, with periodic breath holding for image stabilization. To minimize motion artifact, the iPhone camera was held in a cradle over the carotid artery during iPhone measurements. Regardless of neck morphology, carotid waveforms were captured in all subjects, within seconds to minutes. Seventy-two patients were studied, ranging in age from 20 to 92 years old. The main endpoint of analysis was left ventricular ejection fraction; overall, the correlation between ejection fraction-iPhone and ejection fraction-MRI was 0.74 (r = 0.74; p < 0.0001; ejection fraction-MRI = 0.93 × [ejection fraction-iPhone] + 1.9). Analysis of carotid waveforms using intrinsic frequency methods can be used to document left ventricular ejection fraction with accuracy comparable with that of MRI. The measurements require no training to perform or interpret, no calibration, and can be repeated at the bedside to generate almost continuous analysis of left ventricular ejection fraction without arterial cannulation.
Vennin, Samuel; Mayer, Alexia; Li, Ye; Fok, Henry; Clapp, Brian; Alastruey, Jordi
2015-01-01
Estimation of aortic and left ventricular (LV) pressure usually requires measurements that are difficult to acquire during the imaging required to obtain concurrent LV dimensions essential for determination of LV mechanical properties. We describe a novel method for deriving aortic pressure from the aortic flow velocity. The target pressure waveform is divided into an early systolic upstroke, determined by the water hammer equation, and a diastolic decay equal to that in the peripheral arterial tree, interposed by a late systolic portion described by a second-order polynomial constrained by conditions of continuity and conservation of mean arterial pressure. Pulse wave velocity (PWV, which can be obtained through imaging), mean arterial pressure, diastolic pressure, and diastolic decay are required inputs for the algorithm. The algorithm was tested using 1) pressure data derived theoretically from prespecified flow waveforms and properties of the arterial tree using a single-tube 1-D model of the arterial tree, and 2) experimental data acquired from a pressure/Doppler flow velocity transducer placed in the ascending aorta in 18 patients (mean ± SD: age 63 ± 11 yr, aortic BP 136 ± 23/73 ± 13 mmHg) at the time of cardiac catheterization. For experimental data, PWV was calculated from measured pressures/flows, and mean and diastolic pressures and diastolic decay were taken from measured pressure (i.e., were assumed to be known). Pressure reconstructed from measured flow agreed well with theoretical pressure: mean ± SD root mean square (RMS) error 0.7 ± 0.1 mmHg. Similarly, for experimental data, pressure reconstructed from measured flow agreed well with measured pressure (mean RMS error 2.4 ± 1.0 mmHg). First systolic shoulder and systolic peak pressures were also accurately rendered (mean ± SD difference 1.4 ± 2.0 mmHg for peak systolic pressure). This is the first noninvasive derivation of aortic pressure based on fluid dynamics (flow and wave speed) in the aorta itself. PMID:26163442
NASA Astrophysics Data System (ADS)
Desjardins, Candida L.; Antonelli, Lynn T.; Soares, Edward
2007-02-01
The use of lasers to remotely and non-invasively detect the blood pressure waveform of humans and animals would provide a powerful diagnostic tool. Current blood pressure measurement tools, such as a cuff, are not useful for burn and trauma victims, and animals require catheterization to acquire accurate blood pressure information. The purpose of our sensor method and apparatus invention is to remotely and non-invasively detect the blood pulse waveform of both animals and humans. This device is used to monitor an animal or human's skin in proximity to an artery using radiation from a laser Doppler vibrometer (LDV). This system measures the velocity (or displacement) of the pulsatile motion of the skin, indicative of physiological parameters of the arterial motion in relation to the cardiac cycle. Tests have been conducted that measures surface velocity with an LDV and a signal-processing unit, with enhanced detection obtained with optional hardware including a retro-reflector dot. The blood pulse waveform is obtained by integrating the velocity signal to get surface displacement using standard signal processing techniques. Continuous recording of the blood pulse waveform yields data containing information on cardiac health and can be analyzed to identify important events in the cardiac cycle, such as heart rate, the timing of peak systole, left ventricular ejection time and aortic valve closure. Experimental results are provided that demonstrates the current capabilities of the optical, non-contact sensor for the continuous, non-contact recording of the blood pulse waveform without causing patient distress.
Central venous pulse pressure analysis using an R-synchronized pressure measurement system.
Fujita, Yoshihisa; Hayashi, Daisuke; Wada, Shinya; Yoshioka, Naoki; Yasukawa, Takeshi; Pestel, Gunther
2006-12-01
The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7 mmHg and -0.9+/- 0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CVP at end-diastole during expiration was 0.58+/- 0.81 mmHg. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.
Using impedance cardiography with postural change to stratify patients with hypertension.
DeMarzo, Arthur P
2011-06-01
Early detection of cardiovascular disease in patients with hypertension could initiate appropriate treatment to control blood pressure and prevent the progression of cardiovascular disease. The goal of this study was to show how impedance cardiography waveform analysis with postural change can be used to detect subclinical cardiovascular disease in patients with high blood pressure. Patients with high blood pressure had impedance cardiography data obtained in two positions, standing upright and supine. In 50 adults, impedance cardiography indicated that all patients had abnormal data, with 44 (88%) having multiple abnormalities. Impedance cardiography showed 32 (64%) had ventricular dysfunction, 48 (96%) had vascular load abnormalities, 34 (68%) had hemodynamic abnormalities, 2 (4%) had hypovolemia, and 3 (6%) had hypervolemia. Hypertensive patients have diverse cardiovascular abnormalities that can be quantified by impedance cardiography. By stratifying patients with ventricular, vascular, and hemodynamic abnormalities, treatment could be customized based on the abnormal underlying mechanisms with the potential to rapidly control blood pressure, prevent progression of cardiovascular disease, and possibly reverse remodeling.
Kaku, T; Sakurai, S; Furuno, Y; Yashiro, A; Nakashima, Y; Kuroiwa, A
1995-08-01
We evaluated the effects of systolic anterior motion systolic anterior motion of the mitral valve on cardiac haemodynamics. Seven adult mongrel dogs in which systolic anterior motion-septal contact was observed after dobutamine administration were used. To exclude the effects of left ventricular function and morphology, a stone removal basket catheter was placed in the left ventricular outflow tract, and haemodynamics were compared with the basket closed and opened. The basket was opened five times in three dogs not showing systolic anterior motion-septal contact, but the basket itself did not effect the haemodynamics. In the seven dogs that showed systolic anterior motion-septal contact without left ventricular hypertrophy, the basket was opened a total of 33 times in the presence of various degrees of systolic anterior motion-septal contact. After opening the basket, systolic anterior motion was reduced echocardiographically, and significant (P<0.01) changes were observed in the left ventricle-aorta pressure gradient (from 68 +/- 22 to 25 +/- 15 mm Hg), the systolic ejection period (from 146 +/- 19 to 135 +/- 16 ms), and the stroke volume (SV; from 9.4 +/- 2.9 to 10.1 +/- 3.3 ml). After basket inflation, aortic pressure and aortic flow waveforms changed but the peak pressure and flow velocity did not. The temporal distribution of left ventricular ejection also definitely changed after the basket was opened. No changes were observed in the peak dp/dt, peak negative dp/dt, time constant, left ventricular end-diastolic pressure, or left atrial pressure. These observations in this animal model of systolic anterior motion without left ventricular hypertrophy suggest that: (1) there is no potential for generation of an intra-cavity gradient in the absence of systolic anterior motion of the mitral valve, so that (2) systolic anterior motion narrowed the left ventricular outflow tract and, consequently, produced the systolic ejection period, and affected the left ventricular ejection dynamics, and that (3) the basket catheter is useful because it allows these assessments in the same heart with a nearly fixed left ventricular contractility, at least in our animal model.
Harada, Daisuke; Aasanoi, Hidetsugu; Ushijima, Ryuichi; Noto, Takahisa; Takagawa, Junya; Ishise, Hisanari; Inoue, Hiroshi
2018-06-01
To elucidate involvement of age-related impairments of right ventricular (RV) distensibility in the elderly congestive heart failure (CHF), we examined the prevalence of less-distensible right ventricle in patients with preserved left ventricular ejection fraction (LVEF) over a wide range of ages. In 893 patients aged from 40 to 102 years, we simultaneously recorded electrocardiogram, phonocardiogram, and jugular venous pulse wave. Using signal-processing techniques, the prominent 'Y' descent of jugular pulse waveform was detected as a hemodynamic sign of a less-distensible right ventricle. Prevalence of less-distensible right ventricle and elevated RV systolic pressure increased along with aging from the 50s to the 90s in an exponential fashion from 3.3 and 12% up to 33 and 61%, respectively (p < 0.001 for each). This age-dependent deterioration of ventricular distensibility was not observed for the left ventricle. Higher age and higher RV systolic pressure were independently associated with less-distensible right ventricle (Odds ratio, 1.05 per 1 year, p = 0.003; and 1.03 per 1 mmHg, p = 0.026, respectively). The elderly CHF was associated with high prevalence of the less-distensible right ventricle and higher RV systolic pressure, both of which were independent risk factors for CHF (Odds ratio, 5.27, p = 0.001, and 1.08 per 1 mmHg, p < 0.001, respectively). In elderly patients with preserved LVEF, the combination of a less-distensible right ventricle and a high RV systolic pressure seems to be related to developing CHF. The less-distensible right ventricle and elevated RV systolic pressure are closely associated with CHF with preserved LVEF in the elderly patients.
Vennin, Samuel; Mayer, Alexia; Li, Ye; Fok, Henry; Clapp, Brian; Alastruey, Jordi; Chowienczyk, Phil
2015-09-01
Estimation of aortic and left ventricular (LV) pressure usually requires measurements that are difficult to acquire during the imaging required to obtain concurrent LV dimensions essential for determination of LV mechanical properties. We describe a novel method for deriving aortic pressure from the aortic flow velocity. The target pressure waveform is divided into an early systolic upstroke, determined by the water hammer equation, and a diastolic decay equal to that in the peripheral arterial tree, interposed by a late systolic portion described by a second-order polynomial constrained by conditions of continuity and conservation of mean arterial pressure. Pulse wave velocity (PWV, which can be obtained through imaging), mean arterial pressure, diastolic pressure, and diastolic decay are required inputs for the algorithm. The algorithm was tested using 1) pressure data derived theoretically from prespecified flow waveforms and properties of the arterial tree using a single-tube 1-D model of the arterial tree, and 2) experimental data acquired from a pressure/Doppler flow velocity transducer placed in the ascending aorta in 18 patients (mean ± SD: age 63 ± 11 yr, aortic BP 136 ± 23/73 ± 13 mmHg) at the time of cardiac catheterization. For experimental data, PWV was calculated from measured pressures/flows, and mean and diastolic pressures and diastolic decay were taken from measured pressure (i.e., were assumed to be known). Pressure reconstructed from measured flow agreed well with theoretical pressure: mean ± SD root mean square (RMS) error 0.7 ± 0.1 mmHg. Similarly, for experimental data, pressure reconstructed from measured flow agreed well with measured pressure (mean RMS error 2.4 ± 1.0 mmHg). First systolic shoulder and systolic peak pressures were also accurately rendered (mean ± SD difference 1.4 ± 2.0 mmHg for peak systolic pressure). This is the first noninvasive derivation of aortic pressure based on fluid dynamics (flow and wave speed) in the aorta itself. Copyright © 2015 the American Physiological Society.
Wang, Yu; Koenig, Steven C; Slaughter, Mark S; Giridharan, Guruprasad A
2015-01-01
The risk for left ventricular (LV) suction during left ventricular assist devices (LVAD) support has been a clinical concern. Current development efforts suggest LVAD suction prevention and physiologic control algorithms may require chronic implantation of pressure or flow sensors, which can be unreliable because of baseline drift and short lifespan. To overcome this limitation, we designed a sensorless suction prevention and physiologic control (eSPPC) algorithm that only requires LVAD intrinsic parameters (pump speed and power). Two gain-scheduled, proportional-integral controllers maintain a differential pump speed (ΔRPM) above a user-defined threshold to prevent LV suction while maintaining an average reference differential pressure (ΔP) between the LV and aorta. ΔRPM is calculated from noisy pump speed measurements that are low-pass filtered, and ΔP is estimated using an extended Kalman filter. Efficacy and robustness of the eSPPC algorithm were evaluated in silico during simulated rest and exercise test conditions for 1) excessive ΔP setpoint (ES); 2) rapid eightfold increase in pulmonary vascular resistance (PVR); and 3) ES and PVR. Simulated hemodynamic waveforms (LV pressure and volume; aortic pressure and flow) using only intrinsic pump parameters showed the feasibility of our proposed eSPPC algorithm in preventing LV suction for all test conditions.
Gebhard, Caroline Eva; Desjardins, Georges; Gebhard, Cathérine; Gavra, Paul; Denault, André Y
2017-04-01
To evaluate intratracheal milrinone (tMil) administration for rapid treatment of right ventricular (RV) dysfunction as a novel route after cardiopulmonary bypass. Retrospective analysis. Single-center study. The study comprised 7 patients undergoing cardiac surgery who exhibited acute RV dysfunction after cardiopulmonary bypass. After difficult weaning caused by cardiopulmonary bypass-induced acute RV dysfunction, milrinone was administered as a 5-mg bolus inside the endotracheal tube. RV function improvement, as indicated by decreasing pulmonary artery pressure and changes of RV waveforms, was observed in all 7 patients. Adverse effects of tMil included dynamic RV outflow tract obstruction (2 patients) and a decrease in systemic mean arterial pressure (1 patient). tMil may be an effective, rapid, and easily applicable therapeutic alternative to inhaled milrinone for the treatment of acute RV failure during cardiac surgery. However, sufficiently powered clinical trials are needed to confirm these findings. Copyright © 2017 Elsevier Inc. All rights reserved.
Mueller, Indra; Jansen-Park, So-Hyun; Neidlin, Michael; Steinseifer, Ulrich; Abel, Dirk; Autschbach, Rüdiger; Rossaint, Rolf; Schmitz-Rode, Thomas; Sonntag, Simon Johannes
2017-04-01
Right heart failure (RHF), e.g. due to pulmonary hypertension (PH), is a serious health issue with growing occurrence and high mortality rate. Limited efficacy of medication in advanced stages of the disease constitutes the need for mechanical circulatory support of the right ventricle (RV). An essential contribution to the process of developing right ventricular assist devices (RVADs) is the in vitro test bench, which simulates the hemodynamic behavior of the native circulatory system. To model healthy and diseased arterial-pulmonary hemodynamics in adults (mild and severe PH and RHF), a right heart mock circulation loop (MCL) was developed. Incorporating an anatomically shaped silicone RV and a silicone atrium, it not only enables investigations of hemodynamic values but also suction events or the handling of minimal invasive RVADs in an anatomical test environment. Ventricular pressure-volume loops of all simulated conditions as well as pressure and volume waveforms were recorded and compared to literature data. In an exemplary test, an RVAD was connected to the apex to further test the feasibility of studying such devices with the developed MCL. In conclusion, the hemodynamic behavior of the native system was well reproduced by the developed MCL, which is a useful basis for future RVAD tests.
NASA Astrophysics Data System (ADS)
Bulusu, Kartik V.; Plesniak, Michael W.
2013-11-01
Systolic and diastolic blood pressures, pulse pressures, and left ventricular hypertrophy contribute to cardiovascular risks. Increase of arterial stiffness due to aging and hypertension is an important factor in cardiovascular, chronic kidney and end-stage-renal-diseases. Pulse wave analysis (PWA) based on arterial pressure wave characteristics, is well established in clinical practice for evaluation of arterial distensibility and hypertension. The objective of our exploratory study in a rigid 180-degree curved artery model was to evaluate arterial pressure waveforms. Bend upstream conditions were measured using a two-component, two-dimensional, particle image velocimeter (2C-2D PIV). An ultrasonic transit-time flow meter and a catheter with a MEMS-based solid state pressure sensor, capable of measuring up to 20 harmonics of the observed pressure waveform, monitored flow conditions downstream of the bend. Our novel continuous wavelet transform algorithm (PIVlet 1.2), in addition to detecting coherent secondary flow structures is used to evaluate arterial pulse wave characteristics subjected to physiological and non-physiological inflows. Results of this study will elucidate the utility of wavelet transforms in arterial function evaluation and pulse wave speed. Supported by NSF Grant No. CBET- 0828903 and GW Center for Biomimetics and Bioinspired Engineering.
Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop.
Tuzun, Egemen; Rutten, Marcel; Dat, Marco; van de Vosse, Frans; Kadipasaoglu, Cihan; de Mol, Bas
2011-12-01
As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion--with resul-tant aortic regurgitation--has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we tested a continuous-flow LVAD in a mock circulatory system (MCS) with an interposed valve. To mimic the hemodynamic characteristics of LVAD patients, we utilized an MCS in which a Jarvik 2000 LVAD was positioned at the base of a servomotor-operated piston pump (left ventricular chamber). We operated the LVAD at 8000 to 12,000 rpm, changing the speed in 1000-rpm increments. At each speed, we first varied the outflow resistance at a constant stroke volume, then varied the stroke volume at a constant outflow resistance. We measured the left ventricular pressure, aortic pressure, pump flow, and total flow, and used these values to compute the change, if any, in the aortic duty cycle (aortic valve open time) and transvalvular aortic pressure loads. Validation of the MCS was demonstrated by the simulation of physiologic pressure and flow waveforms. At increasing LVAD speeds, the mean aortic pressure load steadily increased, while the aortic duty cycle steadily decreased. Changes were consistent for each MCS experimental setting, despite variations in stroke volume and outflow resistance. Increased LVAD flow results in an impaired aortic valve-open time due to a pressure overload above the aortic valve. Such an overload may initiate structural changes, causing aortic leaflet fusion and/or regurgitation. Copyright © 2011 Elsevier Inc. All rights reserved.
Huang, Jian; Walcott, Gregory P; Ruse, Richard B; Bohanan, Scott J; Killingsworth, Cheryl R; Ideker, Raymond E
2012-09-11
We tested the hypothesis that the shape of the shock waveform affects not only the defibrillation threshold but also the amount of cardiac damage. Defibrillation thresholds were determined for 11 waveforms-3 ascending-ramp waveforms, 3 descending-ramp waveforms, 3 rectilinear first-phase biphasic waveforms, a Gurvich waveform, and a truncated exponential biphasic waveform-in 6 pigs with electrodes in the right ventricular apex and superior vena cava. The ascending, descending, and rectilinear waveforms had 4-, 8-, and 16-millisecond first phases and a 3.5-millisecond rectilinear second phase that was half the voltage of the first phase. The exponential biphasic waveform had a 60% first-phase and a 50% second-phase tilt. In a second study, we attempted to defibrillate after 10 seconds of ventricular fibrillation with a single ≈30-J shock (6 pigs successfully defibrillated with 8-millisecond ascending, 8-millisecond rectilinear, and truncated exponential biphasic waveforms). Troponin I blood levels were determined before and 2 to 10 hours after the shock. The lowest-energy defibrillation threshold was for the 8-milliseconds ascending ramp (14.6±7.3 J [mean±SD]), which was significantly less than for the truncated exponential (19.6±6.3 J). Six hours after shock, troponin I was significantly less for the ascending-ramp waveform (0.80±0.54 ng/mL) than for the truncated exponential (1.92±0.47 ng/mL) or the rectilinear waveform (1.17±0.45 ng/mL). The ascending ramp has a significantly lower defibrillation threshold and at ≈30 J causes 58% less troponin I release than the truncated exponential biphasic shock. Therefore, the shock waveform affects both the defibrillation threshold and the amount of cardiac damage.
Indik, Julia H.; Donnerstein, Richard L.; Hilwig, Ronald W.; Zuercher, Mathias; Feigelman, Justin; Kern, Karl B.; Berg, Marc D.; Berg, Robert A.
2009-01-01
Objective In cardiac arrest resulting from ventricular fibrillation, the ventricular fibrillation waveform may be a clue to its duration and predict the likelihood of shock success. However, ventricular fibrillation occurs in different myocardial substrates such as ischemia, heart failure, and structurally normal hearts. We hypothesized that ventricular fibrillation is altered by myocardial infarction and varies from the acute to postmyocardial infarction periods. Design An animal intervention study was conducted with comparison to a control group. Setting This study took place in a university animal laboratory. Subjects Study subjects included 37 swine. Interventions Myocardial infarction was induced by occlusion of the midleft anterior descending artery. Ventricular fibrillation was induced in control swine, acute myocardial infarction swine, and in postmyocardial infarction swine after a 2-wk recovery period. Measurements and Main Results Ventricular fibrillation was recorded in 11 swine with acute myocardial infarction, ten post-myocardial infarction, and 16 controls. Frequency (mean, median, dominant, and bandwidth) and amplitude-related content (slope, slope-amp [slope divided by amplitude], and amplitude–spectrum area) were analyzed. Frequencies at 5 mins of ventricular fibrillation were altered in both acute myocardial infarction (p < .001 for all frequency characteristics) and postmyocardial infarction swine (p = .015 for mean, .002 for median, .002 for dominant frequency, and <.001 for bandwidth). At 5 mins, median frequency was highest in controls, 10.9 ± .4 Hz; lowest in acute myocardial infarction, 8.4 ± .5 Hz; and intermediate in postmyocardial infarction, 9.7 ± .5 Hz (p < .001 for acute myocardial infarction and p = .002 for postmyocardial infarction compared with control). Slope and amplitude–spectrum area were similar among the three groups with a shallow decline after minute 2, whereas slope-amp remained significantly altered for acute myocardial infarction swine at 5 mins (p = .003). Conclusions Ventricular fibrillation frequencies depend on myocardial substrate and evolve from the acute through healing phases of myocardial infarction. Amplitude related measures, however, are similar among these groups. It is unknown how defibrillation may be affected by relying on the ventricular fibrillation waveform without considering myocardial substrate. PMID:18552696
Spencer, Kirk T; Weinert, Lynn; Avi, Victor Mor; Decara, Jeanne; Lang, Roberto M
2002-12-01
The Tei index is a combined measurement of systolic and diastolic left ventricular (LV) performance and may be more useful for the diagnosis of global cardiac dysfunction than either systolic or diastolic measures alone. We sought to determine whether the Tei index could be accurately calculated from LV area waveforms generated with automated border detection. Twenty-four patients were studied in 3 groups: systolic dysfunction, diastolic dysfunction, and normal. The Tei index was calculated both from Doppler tracings and from analysis of LV area waveforms. Excellent agreement was found between Doppler-derived timing intervals and the Tei index with those obtained from averaged LV area waveforms. A significant difference was seen in the Tei index, computed with both Doppler and automated border detection techniques, between the normal group and those with LV systolic dysfunction and subjects with isolated diastolic dysfunction. This study validates the use of LV area waveforms for the automated calculation of the Tei index.
Chen, Bihua; Yu, Tao; Ristagno, Giuseppe; Quan, Weilun; Li, Yongqin
2014-10-01
Defibrillation current has been shown to be a clinically more relevant dosing unit than energy. However, the effects of average and peak current in determining shock outcome are still undetermined. The aim of this study was to investigate the relationship between average current, peak current and defibrillation success when different biphasic waveforms were employed. Ventricular fibrillation (VF) was electrically induced in 22 domestic male pigs. Animals were then randomized to receive defibrillation using one of two different biphasic waveforms. A grouped up-and-down defibrillation threshold-testing protocol was used to maintain the average success rate of 50% in the neighborhood. In 14 animals (Study A), defibrillations were accomplished with either biphasic truncated exponential (BTE) or rectilinear biphasic waveforms. In eight animals (Study B), shocks were delivered using two BTE waveforms that had identical peak current but different waveform durations. Both average and peak currents were associated with defibrillation success when BTE and rectilinear waveforms were investigated. However, when pathway impedance was less than 90Ω for the BTE waveform, bivariate correlation coefficient was 0.36 (p=0.001) for the average current, but only 0.21 (p=0.06) for the peak current in Study A. In Study B, a high defibrillation success (67.9% vs. 38.8%, p<0.001) was observed when the waveform delivered more average current (14.9±2.1A vs. 13.5±1.7A, p<0.001) while keeping the peak current unchanged. In this porcine model of VF, average current was better than peak current to be an adequate parameter to describe the therapeutic dosage when biphasic defibrillation waveforms were used. The institutional protocol number: P0805. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Bartoli, Carlo R.; Rogers, Benjamin D.; Ionan, Constantine E.; Koenig, Steven C.; Pantalos, George M.
2013-01-01
OBJECTIVE Counterpulsation with an intraaortic balloon pump (IABP) has not achieved the same successes or clinical use in pediatric patients as in adults. In a pediatric animal model, IABP efficacy was investigated to determine whether IABP timing with a high-fidelity blood pressure signal may improve counterpulsation therapy versus a low-fidelity signal. METHODS In Yorkshire piglets (n=19, 13.0±0.5 kg) with coronary ligation-induced acute ischemic left ventricular failure, pediatric IABPs (5 or 7cc) were placed in the descending thoracic aorta. Inflation and deflation were timed with traditional criteria from low-fidelity (fluid-filled) and high-fidelity (micromanometer) blood pressure signals during 1:1 support. Aortic, carotid, and coronary hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption was calculated from coronary sinus and arterial blood samples. Left ventricular myocardial blood flow and end-organ blood flow were measured with microspheres. RESULTS Despite significant suprasystolic diastolic augmentation and afterload reduction at heart rates of 105±3bmp, left ventricular myocardial blood flow, myocardial oxygen consumption, the myocardial oxygen supply/demand relationship, cardiac output, and end-organ blood flow did not change. Statistically significant end-diastolic coronary, carotid, and aortic flow reversal occurred with IABP deflation. Inflation and deflation timed with a high-fidelity versus low-fidelity signal did not attenuate systemic flow reversal or improve the myocardial oxygen supply/demand relationship. CONCLUSIONS Systemic end-diastolic flow reversal limited counterpulsation efficacy in a pediatric model of acute left ventricular failure. Adjustment of IABP inflation and deflation timing with traditional criteria and a high-fidelity blood pressure waveform did not improve IABP efficacy or attenuate flow reversal. End-diastolic flow reversal may limit the efficacy of IABP counterpulsation therapy in pediatric patients with traditional timing criteria. Investigation of alternative deflation timing strategies is warranted. PMID:24139614
Bartoli, Carlo R; Rogers, Benjamin D; Ionan, Constantine E; Pantalos, George M
2014-05-01
Counterpulsation with an intra-aortic balloon pump (IABP) has not achieved the same success or clinical use in pediatric patients as in adults. In a pediatric animal model, IABP efficacy was investigated to determine whether IABP timing with a high-fidelity blood pressure signal may improve counterpulsation therapy versus a low-fidelity signal. In Yorkshire piglets (n = 19; weight, 13.0 ± 0.5 kg) with coronary ligation-induced acute ischemic left ventricular failure, pediatric IABPs (5 or 7 mL) were placed in the descending thoracic aorta. Inflation and deflation were timed with traditional criteria from low-fidelity (fluid-filled) and high-fidelity (micromanometer) blood pressure signals during 1:1 support. Aortic, carotid, and coronary hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption was calculated from coronary sinus and arterial blood samples. Left ventricular myocardial blood flow and end-organ blood flow were measured with microspheres. Despite significant suprasystolic diastolic augmentation and afterload reduction at heart rates of 105 ± 3 beats per minute, left ventricular myocardial blood flow, myocardial oxygen consumption, the myocardial oxygen supply/demand relationship, cardiac output, and end-organ blood flow did not change. Statistically significant end-diastolic coronary, carotid, and aortic flow reversal occurred with IABP deflation. Inflation and deflation timed with a high-fidelity versus low-fidelity signal did not attenuate systemic flow reversal or improve the myocardial oxygen supply/demand relationship. Systemic end-diastolic flow reversal limited counterpulsation efficacy in a pediatric model of acute left ventricular failure. Adjustment of IABP inflation and deflation timing with traditional criteria and a high-fidelity blood pressure waveform did not improve IABP efficacy or attenuate flow reversal. End-diastolic flow reversal may limit the efficacy of IABP counterpulsation therapy in pediatric patients with traditional timing criteria. Investigation of alternative deflation timing strategies is warranted. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Gazmuri, Raúl J; Kaufman, Christopher L; Baetiong, Alvin; Radhakrishnan, Jeejabai
2016-01-01
Several characteristics of the ventricular fibrillation (VF) waveform have been found predictive of successful defibrillation and hypothesized to reflect the myocardial energy state. In an open-chest swine model of VF, we modeled "average CPR" using extracorporeal circulation (ECC) and assessed the time course of coronary blood flow, myocardial metabolism, and myocardial structure in relation to the amplitude spectral area (AMSA) of the VF waveform without artifacts related to chest compression. VF was induced and left untreated for 8 minutes in 16 swine. ECC was then started adjusting its flow to maintain a coronary perfusion pressure of 10 mmHg for 10 minutes. AMSA was calculated in the frequency domain and analyzed continuously with a 2.1 s timeframe and a Tukey window that moved ahead every 0.5 s. AMSA progressively declined during untreated VF. With ECC, AMSA increased from 7.0 ± 1.9 mV·Hz (at minute 8) to 12.8 ± 3.3 mV·Hz (at minute 14) (p < 0.05) without subsequent increase and showing a modest correlation with coronary blood flow of borderline statistical significance (r = 0.489, p = 0.0547). Myocardial energy measurements showed marked reduction in phosphocreatine and moderate reduction in ATP with increases in ADP, AMP, and adenosine along with myocardial lactate, all indicative of ischemia. Yet, ischemia did not resolve during ECC despite a coronary blood flow of ~ 30% of baseline. AMSA increased upon return of coronary blood flow during ECC. However, the maximal level was reached after ~ 6 minutes without further change. The significance of the findings for determining the optimal timing for delivering an electrical shock during resuscitation from VF remains to be further explored.
Okamura, Hideo; Desimone, Christopher V; Killu, Ammar M; Gilles, Emily J; Tri, Jason; Asirvatham, Roshini; Ladewig, Dejae J; Suddendorf, Scott H; Powers, Joanne M; Wood-Wentz, Christina M; Gray, Peter D; Raymond, Douglas M; Savage, Shelley J; Savage, Walter T; Bruce, Charles J; Asirvatham, Samuel J; Friedman, Paul A
2017-02-01
Automated external defibrillators can provide life-saving therapies to treat ventricular fibrillation. We developed a prototype unit that can deliver a unique shock waveform produced by four independent capacitors that is delivered through two shock vectors, with the rationale of providing more robust shock pathways during emergent defibrillation. We describe the initial testing and feasibility of this unique defibrillation unit, features of which may enable downsizing of current defibrillator devices. We tested our defibrillation unit in four large animal models (two canine and two swine) under general anesthesia. Experimental defibrillation thresholds (DFT) were obtained by delivery of a unique waveform shock pulse via a dual-vector pathway with four defibrillation pads (placed across the chest). DFTs were measured and compared with those of a commercially available biphasic defibrillator (Zoll M series, Zoll Medical, Chelmsford, MA, USA) tested in two different vectors. Shocks were delivered after 10 seconds of stable ventricular fibrillation and the output characteristics and shock outcome recorded. Each defibrillation series used a step-down to failure protocol to define the defibrillation threshold. A total of 96 shocks were delivered during ventricular fibrillation in four large animals. In comparison to the Zoll M series, which delivered a single-vector, biphasic shock, the energy required for successful defibrillation using the unique dual-vector biphasic waveform did not differ significantly (P = 0.65). Our early findings support the feasibility of a unique external defibrillation unit using a dual-vector biphasic waveform approach. This warrants further study to leverage this unique concept and work toward a miniaturized, portable shock delivery system. © 2016 Wiley Periodicals, Inc.
Granegger, Marcus; Moscato, Francesco; Casas, Fernando; Wieselthaler, Georg; Schima, Heinrich
2012-08-01
Estimation of instantaneous flow in rotary blood pumps (RBPs) is important for monitoring the interaction between heart and pump and eventually the ventricular function. Our group has reported an algorithm to derive ventricular contractility based on the maximum time derivative (dQ/dt(max) as a substitute for ventricular dP/dt(max) ) and pulsatility of measured flow signals. However, in RBPs used clinically, flow is estimated with a bandwidth too low to determine dQ/dt(max) in the case of improving heart function. The aim of this study was to develop a flow estimator for a centrifugal pump with bandwidth sufficient to provide noninvasive cardiac diagnostics. The new estimator is based on both static and dynamic properties of the brushless DC motor. An in vitro setup was employed to identify the performance of pump and motor up to 20 Hz. The algorithm was validated using physiological ventricular and arterial pressure waveforms in a mock loop which simulated different contractilities (dP/dt(max) 600 to 2300 mm Hg/s), pump speeds (2 to 4 krpm), and fluid viscosities (2 to 4 mPa·s). The mathematically estimated pump flow data were then compared to the datasets measured in the mock loop for different variable combinations (flow ranging from 2.5 to 7 L/min, pulsatility from 3.5 to 6 L/min, dQ/dt(max) from 15 to 60 L/min/s). Transfer function analysis showed that the developed algorithm could estimate the flow waveform with a bandwidth up to 15 Hz (±2 dB). The mean difference between the estimated and measured average flows was +0.06 ± 0.31 L/min and for the flow pulsatilities -0.27 ± 0.2 L/min. Detection of dQ/dt(max) was possible up to a dP/dt(max) level of 2300 mm Hg/s. In conclusion, a flow estimator with sufficient frequency bandwidth and accuracy to allow determination of changes in ventricular contractility even in the case of improving heart function was developed. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
[Wearable Automatic External Defibrillators].
Luo, Huajie; Luo, Zhangyuan; Jin, Xun; Zhang, Leilei; Wang, Changjin; Zhang, Wenzan; Tu, Quan
2015-11-01
Defibrillation is the most effective method of treating ventricular fibrillation(VF), this paper introduces wearable automatic external defibrillators based on embedded system which includes EGG measurements, bioelectrical impedance measurement, discharge defibrillation module, which can automatic identify VF signal, biphasic exponential waveform defibrillation discharge. After verified by animal tests, the device can realize EGG acquisition and automatic identification. After identifying the ventricular fibrillation signal, it can automatic defibrillate to abort ventricular fibrillation and to realize the cardiac electrical cardioversion.
NASA Astrophysics Data System (ADS)
Nomura, Fumimasa; Hattori, Akihiro; Terazono, Hideyuki; Kim, Hyonchol; Odaka, Masao; Sugio, Yoshihiro; Yasuda, Kenji
2016-06-01
For the prediction of lethal arrhythmia occurrence caused by abnormality of cell-to-cell conduction, we have developed a next-generation in vitro cell-to-cell conduction assay, i.e., a quasi in vivo assay, in which the change in spatial cell-to-cell conduction is quantitatively evaluated from the change in waveforms of the convoluted electrophysiological signals from lined-up cardiomyocytes on a single closed loop of a microelectrode of 1 mm diameter and 20 µm width in a cultivation chip. To evaluate the importance of the closed-loop arrangement of cardiomyocytes for prediction, we compared the change in waveforms of convoluted signals of the responses in the closed-loop circuit arrangement with that of the response of cardiomyocyte clusters using a typical human ether a go-go related gene (hERG) ion channel blocker, E-4031. The results showed that (1) waveform prolongation and fluctuation both in the closed loops and clusters increased depending on the E-4031 concentration increase. However, (2) only the waveform signals in closed loops showed an apparent temporal change in waveforms from ventricular tachycardia (VT) to ventricular fibrillation (VF), which is similar to the most typical cell-to-cell conductance abnormality. The results indicated the usefulness of convoluted waveform signals of a closed-loop cell network for acquiring reproducible results acquisition and more detailed temporal information on cell-to-cell conduction.
Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Matsuo, Satoshi; Saiki, Yoshikatsu; Yamagishi, Masaaki
2015-01-01
Pulmonary conduit valves are used as one of the surgical treatment methods of congenital heart diseases. We have been designing a sophisticated pulmonary conduit valve for the right ventricular outflow tract reconstruction in pediatric patients. In this study, two types of polyester grafts with or without bulging structures for the conduit valves were used and evaluated from the hemodynamic point of view focusing on the application of these conduit valves in the grown-up congenital heart failure patients. We examined valvular function in the originally developed pulmonary mock circulatory system, which consisted of a pneumatic driven right ventricular model, a pulmonary valve chamber, and an elastic pulmonary compliance model with peripheral vascular resistance units. Prior to the measurement, a bileaflet valve was sutured in each conduit. Each conduit valve was installed in the mock right ventricular outflow portion, and its leaflet motion was obtained by using a high-speed camera synchronously with pressure and flow waveforms. As a result, we could obtain hemodynamic changes in two different types of conduits for pulmonary valves, and it was indicated that the presence of the Valsalva shape might be effective for promoting valvular response in the low cardiac output condition.
The effect of acetyl strophanthidin on the hearts of normal dogs.
Hayes, A H; McShane, W P; Sidell, F R
1970-05-01
1. The ED50 of acetyl strophanthidin for producing ventricular arrhythmias in normal dogs was 54.5 mug/kg intravenously.2. Doses up to and including those which caused ventricular tachycardia did not produce either atrial arrhythmias or significant aberration of A-V conduction.3. Although the classic digitalis-induced rate and e.c.g. waveform changes may appear after administration of acetyl strophanthidin, their presence or absence have no value in predicting the subsequent development of ventricular arrhythmias.
Okada, Kazunori; Kaga, Sanae; Mikami, Taisei; Masauzi, Nobuo; Abe, Ayumu; Nakabachi, Masahiro; Yokoyama, Shinobu; Nishino, Hisao; Ichikawa, Ayako; Nishida, Mutsumi; Murai, Daisuke; Hayashi, Taichi; Shimizu, Chikara; Iwano, Hiroyuki; Yamada, Satoshi; Tsutsui, Hiroyuki
2017-05-01
We analyzed the waveform of systolic strain and strain-rate curves to find a characteristic left ventricular (LV) myocardial contraction pattern in patients with hypertrophic cardiomyopathy (HCM), and evaluated the utility of these parameters for the differentiation of HCM and LV hypertrophy secondary to hypertension (HT). From global strain and strain-rate curves in the longitudinal and circumferential directions, the time from mitral valve closure to the peak strains (T-LS and T-CS, respectively) and the peak systolic strain rates (T-LSSR and T-CSSR, respectively) were measured in 34 patients with HCM, 30 patients with HT, and 25 control subjects. The systolic strain-rate waveform was classified into 3 patterns ("V", "W", and "√" pattern). In the HCM group, T-LS was prolonged, but T-LSSR was shortened; consequently, T-LSSR/T-LS ratio was distinctly lower than in the HT and control groups. The "√" pattern of longitudinal strain-rate waveform was more frequently seen in the HCM group (74 %) than in the control (4 %) and HT (20 %) groups. Similar but less distinct results were obtained in the circumferential direction. To differentiate HCM from HT, the sensitivity and specificity of the T-LSSR/T-LS ratio <0.34 and the "√"-shaped longitudinal strain-rate waveform were 85 and 63 %, and 74 and 80 %, respectively. In conclusion, in patients with HCM, a reduced T-LSSR/T-LS ratio and a characteristic "√"-shaped waveform of LV systolic strain rate was seen, especially in the longitudinal direction. The timing and waveform analyses of systolic strain rate may be useful to distinguish between HCM and HT.
Freese, John P; Jorgenson, Dawn B; Liu, Ping-Yu; Innes, Jennifer; Matallana, Luis; Nammi, Krishnakant; Donohoe, Rachael T; Whitbread, Mark; Silverman, Robert A; Prezant, David J
2013-08-27
Ventricular fibrillation (VF) waveform properties have been shown to predict defibrillation success and outcomes among patients treated with immediate defibrillation. We postulated that a waveform analysis algorithm could be used to identify VF unlikely to respond to immediate defibrillation, allowing selective initial treatment with cardiopulmonary resuscitation in an effort to improve overall survival. In a multicenter, double-blind, randomized study, out-of-hospital cardiac arrest patients in 2 urban emergency medical services systems were treated with automated external defibrillators using either a VF waveform analysis algorithm or the standard shock-first protocol. The VF waveform analysis used a predefined threshold value below which return of spontaneous circulation (ROSC) was unlikely with immediate defibrillation, allowing selective treatment with a 2-minute interval of cardiopulmonary resuscitation before initial defibrillation. The primary end point was survival to hospital discharge. Secondary end points included ROSC, sustained ROSC, and survival to hospital admission. Of 6738 patients enrolled, 987 patients with VF of primary cardiac origin were included in the primary analysis. No immediate or long-term survival benefit was noted for either treatment algorithm (ROSC, 42.5% versus 41.2%, P=0.70; sustained ROSC, 32.4% versus 33.4%, P=0.79; survival to admission, 34.1% versus 36.4%, P=0.46; survival to hospital discharge, 15.6% versus 17.2%, P=0.55, respectively). Use of a waveform analysis algorithm to guide the initial treatment of out-of-hospital cardiac arrest patients presenting in VF did not improve overall survival compared with a standard shock-first protocol. Further study is recommended to examine the role of waveform analysis for the guided management of VF.
Pennell, Thomas; Yi, Juneyoung L; Kaufman, Bruce A; Krishnamurthy, Satish
2016-03-01
OBJECT Mechanical failure-which is the primary cause of CSF shunt malfunction-is not readily diagnosed, and the specific reasons for mechanical failure are not easily discerned. Prior attempts to measure CSF flow noninvasively have lacked the ability to either quantitatively or qualitatively obtain data. To address these needs, this preliminary study evaluates an ultrasonic transit time flow sensor in pediatric and adult patients with external ventricular drains (EVDs). One goal was to confirm the stated accuracy of the sensor in a clinical setting. A second goal was to observe the sensor's capability to record real-time continuous CSF flow. The final goal was to observe recordings during instances of flow blockage or lack of flow in order to determine the sensor's ability to identify these changes. METHODS A total of 5 pediatric and 11 adult patients who had received EVDs for the treatment of hydrocephalus were studied in a hospital setting. The primary EVD was connected to a secondary study EVD that contained a fluid-filled pressure transducer and an in-line transit time flow sensor. Comparisons were made between the weight of the drainage bag and the flow measured via the sensor in order to confirm its accuracy. Data from the pressure transducer and the flow sensor were recorded continuously at 100 Hz for a period of 24 hours by a data acquisition system, while the hourly CSF flow into the drip chamber was recorded manually. Changes in the patient's neurological status and their time points were noted. RESULTS The flow sensor demonstrated a proven accuracy of ± 15% or ± 2 ml/hr. The flow sensor allowed real-time continuous flow waveform data recordings. Dynamic analysis of CSF flow waveforms allowed the calculation of the pressure-volume index. Lastly, the sensor was able to diagnose a blocked catheter and distinguish between the blockage and lack of flow. CONCLUSIONS The Transonic flow sensor accurately measures CSF output within ± 15% or ± 2 ml/hr, diagnoses the blockage or lack of flow, and records real-time continuous flow data in patients with EVDs. Calculations of a wide variety of diagnostic parameters can be made from the waveform recordings, including resistance and compliance of the ventricular catheters and the compliance of the brain. The sensor's clinical applications may be of particular importance to the noninvasive diagnosis of shunt malfunctions with the development of an implantable device.
NASA Technical Reports Server (NTRS)
Elliott, Morgan; Martin, David
2015-01-01
For my summer internship project, I organized a pilot study to analyze the effects of a cephalic fluid shift on venous return and right ventricular mechanics to increase right ventricular and venous knowledge. To accomplish this pilot study, I wrote a testing protocol, obtained Institutional Review Board (IRB) approval, completed subject payment forms, lead testing sessions, and analyzed the data. This experiment used -20deg head down tilt (20 HDT) as the ground based simulation for the fluid shift that occurs during spaceflight and compared it to data obtained from the seated and supine positions. Using echocardiography, data was collected for the right ventricle, hepatic vein, internal jugular vein, external jugular vein, and inferior vena cava. Additionally, non-invasive venous pressure measurements, similar to those soon to be done in-orbit, were collected. It was determined that the venous return from below the heard is increased during 20 HDT, which was supported by increased hepatic vein velocities, increased right ventricular inflow, and increased right ventricular strain at 20 HDT relative to seated values. Jugular veins in the neck undergo an increase in pressure and area, but no significant increase in flow, relative to seated values when a subject is tilted 20 HDT. Contrary to the initial expectations based on this jugular flow, there was no significant increase in central venous pressure, as evidenced by no change in Doppler indices for right arterial pressure or inferior vena cava diameter. It is suspected that these differences in pressure are due to the hydrostatic pressure indifference point shifting during tilt; there is a potential for a similar phenomenon with microgravity. This data will hopefully lead to a more in-depth understanding of the response of the body to microgravity and how those relate to the previously mentioned cardiovascular risk of fluid shift that is associated with spaceflight. These results were presented in greater detail to the Cardiovascular Laboratory and the Space Life Science Summer Institute, which helped me prepare for future graduate school research presentations. This internship allowed me to apply and expand the anatomy, physiology, and mechanics information I learned during my undergraduate degree in Biomedical Engineering to the cardiovascular system with the unique zero gravity perspective. Additionally, I was able to develop skills with data analysis techniques involving speckle tracking for ventricular strain and Doppler waveforms for blood velocities. Additionally, I was able to expand upon my previous work in the Cardiovascular Laboratory by writing a literature review on a data analysis project I completed last summer. Ultimately, this internship and venous relationship comparison project provided me with a significant learning experience and additional skill sets, which are applicable to my goals of attaining a Ph.D. in biomedical engineering with a focus on tissue engineering and the cardiovascular system.
2014-11-01
networks were trained to predict an individual’s electrocardiogram (ECG) and arterial blood pressure ( ABP ) waveform data, which can potentially help...various ESN architectures for prediction tasks, and establishes the benefits of using ESN architecture designs for predicting ECG and ABP waveforms...arterial blood pressure ( ABP ) waveforms immediately prior to the machine generated alarms. When tested, the algorithm suppressed approximately 59.7
Zhou, Haibin; Zhang, Yongmin; Han, Ruoyu; Jing, Yan; Wu, Jiawei; Liu, Qiaojue; Ding, Weidong; Qiu, Aici
2016-04-22
Underwater shock waves (SWs) generated by underwater electrical wire explosions (UEWEs) have been widely studied and applied. Precise measurement of this kind of SWs is important, but very difficult to accomplish due to their high peak pressure, steep rising edge and very short pulse width (on the order of tens of μs). This paper aims to analyze the signals obtained by two kinds of commercial piezoelectric pressure probes, and reconstruct the correct pressure waveform from the distorted one measured by the pressure probes. It is found that both PCB138 and Müller-plate probes can be used to measure the relative SW pressure value because of their good uniformities and linearities, but none of them can obtain precise SW waveforms. In order to approach to the real SW signal better, we propose a new multi-exponential pressure waveform model, which has considered the faster pressure decay at the early stage and the slower pressure decay in longer times. Based on this model and the energy conservation law, the pressure waveform obtained by the PCB138 probe has been reconstructed, and the reconstruction accuracy has been verified by the signals obtained by the Müller-plate probe. Reconstruction results show that the measured SW peak pressures are smaller than the real signal. The waveform reconstruction method is both reasonable and reliable.
Zhou, Haibin; Zhang, Yongmin; Han, Ruoyu; Jing, Yan; Wu, Jiawei; Liu, Qiaojue; Ding, Weidong; Qiu, Aici
2016-01-01
Underwater shock waves (SWs) generated by underwater electrical wire explosions (UEWEs) have been widely studied and applied. Precise measurement of this kind of SWs is important, but very difficult to accomplish due to their high peak pressure, steep rising edge and very short pulse width (on the order of tens of μs). This paper aims to analyze the signals obtained by two kinds of commercial piezoelectric pressure probes, and reconstruct the correct pressure waveform from the distorted one measured by the pressure probes. It is found that both PCB138 and Müller-plate probes can be used to measure the relative SW pressure value because of their good uniformities and linearities, but none of them can obtain precise SW waveforms. In order to approach to the real SW signal better, we propose a new multi-exponential pressure waveform model, which has considered the faster pressure decay at the early stage and the slower pressure decay in longer times. Based on this model and the energy conservation law, the pressure waveform obtained by the PCB138 probe has been reconstructed, and the reconstruction accuracy has been verified by the signals obtained by the Müller-plate probe. Reconstruction results show that the measured SW peak pressures are smaller than the real signal. The waveform reconstruction method is both reasonable and reliable. PMID:27110789
DeMarzo, Arthur P; Kelly, Russell F; Calvin, James E
2007-01-01
Early detection of asymptomatic left ventricular systolic dysfunction (LVSD) is beneficial in managing heart failure. Recent studies have cast doubt on the usefulness of cardiac output as an indicator of LVSD. In impedance cardiography (ICG), the dZ/dt waveform has a systolic wave called the E wave. This study looked at measurements of the amplitude and area of the E wave compared with ICG-derived cardiac output, stroke volume, cardiac index, and stroke index as methods of assessing LVSD. ICG data were obtained from patients (n=26) admitted to a coronary care unit. Clinical LVSD severity was stratified into 4 groups (none, mild, moderate, and severe) based on echocardiography data and standard clinical assessment by a cardiologist blinded to ICG data. Statistical analysis showed that the E wave amplitude and area were better indicators of the level of LVSD than cardiac output, stroke volume, cardiac index, or stroke index. ICG waveform analysis has potential as a simple point-of-care test for detecting LVSD in asymptomatic patients at high risk for developing heart failure and for monitoring LVSD in patients being treated for heart failure.
Mizuno, Ju; Mohri, Satoshi; Yokoyama, Takeshi; Otsuji, Mikiya; Arita, Hideko; Hanaoka, Kazuo
2017-02-01
Varying temperature affects cardiac systolic and diastolic function and the left ventricular (LV) pressure-time curve (PTC) waveform that includes information about LV inotropism and lusitropism. Our proposed half-logistic (h-L) time constants obtained by fitting using h-L functions for four segmental phases (Phases I-IV) in the isovolumic LV PTC are more useful indices for estimating LV inotropism and lusitropism during contraction and relaxation periods than the mono-exponential (m-E) time constants at normal temperature. In this study, we investigated whether the superiority of the goodness of h-L fits remained even at hypothermia and hyperthermia. Phases I-IV in the isovolumic LV PTCs in eight excised, cross-circulated canine hearts at 33, 36, and 38 °C were analyzed using h-L and m-E functions and the least-squares method. The h-L and m-E time constants for Phases I-IV significantly shortened with increasing temperature. Curve fitting using h-L functions was significantly better than that using m-E functions for Phases I-IV at all temperatures. Therefore, the superiority of the goodness of h-L fit vs. m-E fit remained at all temperatures. As LV inotropic and lusitropic indices, temperature-dependent h-L time constants could be more useful than m-E time constants for Phases I-IV.
Pérez-Lahiguera, Francisco J; Rodilla, Enrique; Costa, Jose A; Gonzalez, Carmen; Martín, Joaquin; Pascual, Jose M
2012-12-01
The purpose of the present study was to assess the relationship of central and peripheral blood pressure to left ventricular mass. Cross-sectional study that included 392 never treated hypertensive individuals. Measurement of office, 24-h ambulatory, and central blood pressure (obtained using applanation tonometry) and determination of left ventricular mass by echocardiography were performed in all patients. In a multiple regression analysis, with adjustment for age, gender and metabolic syndrome, 24-h blood pressure was more closely related to ventricular mass than the respective office and central blood pressures. Systolic blood pressures always exhibited a higher correlation than diastolic blood pressures in all 3 determinations. The correlation between left ventricular mass index and 24-h systolic blood pressure was higher than that of office (P<.002) or central systolic blood pressures (P<.002). Changes in 24-h systolic blood pressure caused the greatest variations in left ventricular mass index (P<.001). In our population of untreated middle-aged hypertensive patients, left ventricular mass index is more closely related to 24-h ambulatory blood pressure than to office or central blood pressure. Central blood pressure does not enable us to better identify patients with left ventricular hypertrophy. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Doppler waveform study as indicator of change of portal pressure after administration of octreotide
Haider, Shahbaz; Hussain, Qurban; Tabassum, Sumera; Hussain, Bilal; Durrani, Muhammad Rasheed; Ahmed, Fayyaz
2016-01-01
Objective: To estimate the effect of portal pressure lowering drug ‘octreotide’, by observing the Doppler waveform before and after the administration of intravenous bolus of octreotide and thus to assess indirectly its efficacy to lower the portal pressure. Methods: This quassi experimental study was carried out in Medical Department in collaboration with Radiology Department of Jinnah Postgraduate Medical Center Karachi Pakistan from September 10, 2015 to February 5, 2016. Cases were selected from patients admitted in Medical Wards and those attending Medical OPD. Diagnosis of cirrhosis was confirmed by Clinical Examination and Lab & Imaging investigation in Medical Department. Doppler waveform study was done by experienced radiologist in Radiology Department before and after administration of octreotide. Doppler signals were obtained from the right hepatic vein. Waveform tracings were recorded for five seconds and categorized as ‘monophasic’, ‘biphasic’ and ‘triphasic’. Waveform changes from one waveform to other were noted and analyzed. Results: Significant change i.e. from ‘monophasic’ to ‘biphasic’ or ‘biphasic’ to ‘triphasic’ was seen in 56% cases while ‘monophasic’ to ‘triphasic’ was seen in 20% cases. No change was seen in 24% cases. Improvement in waveform reflects lowering of portal vein pressure. Conclusion: Non invasive Hepatic vein Doppler waveform study showed improvement in Doppler waveform after administration of octreotide in 76% cases. Doppler waveform study has the potential of becoming non invasive ‘follow up tool’ of choice for assessing portal pressure in patients having variceal bleed due to portal hypertension. PMID:27648043
Analysis of baroreflex sensitivity during undulation pump ventricular assist device support.
Liu, Hongjian; Shiraishi, Yasuyuki; Zhang, Xiumin; Song, Hojin; Saijo, Yoshifumi; Baba, Atsushi; Yambe, Tomoyuki; Abe, Yusuke; Imachi, Kou
2009-07-01
The aim of this study was to examine the baroreflex sensitivity (BRS), which involves the autonomic nervous system, in a goat with a chronically implanted undulation pump ventricular assist device (UPVAD). The UPVAD involved transforming the rotation of a brushless DC motor into an undulating motion by a disc attached via a special linking mechanism, and a jellyfish valve in the outflow cannula to prevent diastolic backflow. The pump was implanted into the thoracic cavity of a goat by a left thoracotomy, and the inflow and outflow cannulae were sutured to the apex of the left ventricle and to the descending aorta, respectively. The driving cable was wired percutaneously to an external controller. Electrocardiogram and hemodynamic waveforms were recorded at a sampling frequency of 1 kHz. BRS was determined when awake by the slope of the linear regression of R-R interval against mean arterial pressure changes, which were induced by the administration of methoxamine hydrochloride, both with continuous driving of the UPVAD as well as without assistance. BRS values during the UPVAD support and without assistance were 1.60 +/- 0.30 msec/mm Hg and 0.98 +/- 0.22 msec/mm Hg (n = 5, P < 0.05), respectively. BRS was significantly improved during left ventricular assistance. Therefore, UPVAD support might decrease sympathetic nerve activity and increase parasympathetic nerve activity to improve both microcirculation and organ function.
Diastolic function of the nonfilling human left ventricle.
Paulus, W J; Vantrimpont, P J; Rousseau, M F
1992-12-01
To investigate an early-diastolic left ventricular suction effect in humans, tip-micromanometer left ventricular pressure recordings were obtained in patients with mitral stenosis at the time of balloon inflations during percutaneous mitral valvuloplasty performed with a self-positioning Inoue balloon, which fits tightly in the mitral orifice. When mitral inflow was impeded in anesthetized dogs, left ventricular pressure decayed to a negative asymptote value. This negative asymptote value was consistent with an early diastolic suction effect. Tip-micromanometer left ventricular pressure recordings were obtained in 23 patients with symptomatic mitral stenosis at the time of balloon inflations during percutaneous mitral valvuloplasty performed with a self-positioning Inoue balloon. The left ventricular diastolic asymptote pressure (P(asy)) was determined in 47 nonfilling beats with a sufficiently long (greater than 200 ms) diastolic time interval (that is, the interval from minimal first derivative of left ventricular pressure to left ventricular end-diastolic pressure) and equaled 2 +/- 3 mm Hg for beats with normal intraventricular conduction and 3 +/- 2 mm Hg for beats with aberrant intraventricular conduction. Left ventricular angiography was performed in five patients during the first inflation of the Inoue balloon at the time of complete balloon expansion. Left ventricular end-diastolic volume of the nonfilling beats averaged 38 +/- 14 ml and was comparable to the left ventricular end-systolic volume (39 +/- 19 ml) measured during baseline angiography before mitral valvuloplasty. Time constants of left ventricular pressure decay were calculated on 21 nonfilling beats with a diastolic time interval greater than 200 ms, normal intraventricular conduction and peak left ventricular pressure greater than 50 mm Hg. Time constants (T0 and TBF) derived from an exponential curve fit with zero asymptote pressure and with a best-fit asymptote pressure were compared with a time constant (T(asy)) derived from an exponential curve fit with the measured diastolic left ventricular asymptote pressure. The value for T(asy) (37 +/- 9 ms) was significantly smaller than that for TBF (68 +/- 28 ms, p less than 0.001) and the value for the measured diastolic left ventricular asymptote pressure (2 +/- 4 mm Hg) was significantly larger than that for the best-fit asymptote pressure (-9 +/- 11 mm Hg, p less than 0.001). T0 (44 +/- 20 ms) was significantly (p less than 0.01) different from TBF but not from T(asy). During balloon inflation of a self-positioning Inoue balloon, left ventricular pressure decayed continuously toward a positive asymptote value and left ventricular cavity volume was comparable to the left ventricular end-systolic volume of filling beats. In these nonfilling beats, the best-fit asymptote pressure was unrelated to the measured asymptote pressure and T0 was a better measure of T(asy) than was TBF. Reduced internal myocardial restoring forces, caused by different extracellular matrix of the human heart, reduced external myocardial restoring forces caused by low coronary perfusion pressure during the balloon inflation and inward motion of the balloon-occluded mitral valve into the left ventricular cavity could explain the failure to observe significant diastolic left ventricular suction in the human heart.
Syed, Hasson; Unnikrishnan, Vinu U; Olcmen, Semih
2016-02-01
Elevated intracranial pressure is a major contributor to morbidity and mortality in severe head injuries. Wall shear stresses in the artery can be affected by increased intracranial pressures and may lead to the formation of cerebral aneurysms. Earlier research on cerebral arteries and aneurysms involves using constant mean intracranial pressure values. Recent advancements in intracranial pressure monitoring techniques have led to measurement of the intracranial pressure waveform. By incorporating a time-varying intracranial pressure waveform in place of constant intracranial pressures in the analysis of cerebral arteries helps in understanding their effects on arterial deformation and wall shear stress. To date, such a robust computational study on the effect of increasing intracranial pressures on the cerebral arterial wall has not been attempted to the best of our knowledge. In this work, fully coupled fluid-structure interaction simulations are carried out to investigate the effect of the variation in intracranial pressure waveforms on the cerebral arterial wall. Three different time-varying intracranial pressure waveforms and three constant intracranial pressure profiles acting on the cerebral arterial wall are analyzed and compared with specified inlet velocity and outlet pressure conditions. It has been found that the arterial wall experiences deformation depending on the time-varying intracranial pressure waveforms, while the wall shear stress changes at peak systole for all the intracranial pressure profiles. © IMechE 2015.
Estimation of diastolic intraventricular pressure gradients by Doppler M-mode echocardiography
NASA Technical Reports Server (NTRS)
Greenberg, N. L.; Vandervoort, P. M.; Firstenberg, M. S.; Garcia, M. J.; Thomas, J. D.
2001-01-01
Previous studies have shown that small intraventricular pressure gradients (IVPG) are important for efficient filling of the left ventricle (LV) and as a sensitive marker for ischemia. Unfortunately, there has previously been no way of measuring these noninvasively, severely limiting their research and clinical utility. Color Doppler M-mode (CMM) echocardiography provides a spatiotemporal velocity distribution along the inflow tract throughout diastole, which we hypothesized would allow direct estimation of IVPG by using the Euler equation. Digital CMM images, obtained simultaneously with intracardiac pressure waveforms in six dogs, were processed by numerical differentiation for the Euler equation, then integrated to estimate IVPG and the total (left atrial to left ventricular apex) pressure drop. CMM-derived estimates agreed well with invasive measurements (IVPG: y = 0.87x + 0.22, r = 0.96, P < 0.001, standard error of the estimate = 0.35 mmHg). Quantitative processing of CMM data allows accurate estimation of IVPG and tracking of changes induced by beta-adrenergic stimulation. This novel approach provides unique information on LV filling dynamics in an entirely noninvasive way that has previously not been available for assessment of diastolic filling and function.
Steinhaus, David; Reynolds, Dwight W; Gadler, Fredrik; Kay, G Neal; Hess, Mike F; Bennett, Tom
2005-08-01
Management of congestive heart failure is a serious public health problem. The use of implantable hemodynamic monitors (IHMs) may assist in this management by providing continuous ambulatory filling pressure status for optimal volume management. The Chronicle system includes an implanted monitor, a pressure sensor lead with passive fixation, an external pressure reference (EPR), and data retrieval and viewing components. The tip of the lead is placed near the right ventricular outflow tract to minimize risk of sensor tissue encapsulation. Implant technique and lead placement is similar to that of a permanent pacemaker. After the system had been successfully implanted in 148 patients, the type and frequency of implant-related adverse events were similar to a single-chamber pacemaker implant. R-wave amplitude was 15.2 +/- 6.7 mV and the pressure waveform signal was acceptable in all but two patients in whom presence of artifacts required lead repositioning. Implant procedure time was not influenced by experience, remaining constant throughout the study. Based on this evaluation, permanent placement of an IHM in symptomatic heart failure patients is technically feasible. Further investigation is warranted to evaluate the use of the continuous hemodynamic data in management of heart failure patients.
Ambler, Jonathan J S; Deakin, Charles D
2006-11-01
Biphasic waveforms have similar or greater efficacy at cardioverting atrial and ventricular arrhythmias at lower energy levels than monophasic waveforms, and cause less ST depression following defibrillation of ventricular fibrillation. No studies have investigated this effect on ST change with atrial arrhythmias. We studied the efficacy of the Welch Allyn-MRL PIC biphasic defibrillator. One hundred and thirty-nine patients undergoing elective DC cardioversion for atrial arrhythmias were randomised to cardioversion by monophasic (Hewlett Packard Codemaster XL; 100, 200, 300, 360 and 360J) or biphasic (Welch Allyn-MRL PIC; 70, 100, 150, 200 and 300J) defibrillator. We analysed success of cardioversion after 0 and 30min, cumulative energy, number of shocks and energy at successful cardioversion. The ST change in the recorded electrocardiogram was measured at 15s after all shocks using electronic callipers. Immediately after cardioversion 59/68 (86.8%) of the monophasic group versus 56/60 (93.3%) of the biphasic group were in sinus rhythm. Of the monophasic group, 55/67 (82.1%) remained in sinus rhythm at 30min versus 53/58 (91.4%) of the biphasic group. These differences were not significant at 0min (P=0.35) or 30min (P=0.21). The biphasic group required significantly fewer shocks (P=0.006), less cumulative energy (P<0.0001) and required lower total energy for successful cardioversion (P<0.0001). Of the 102 patients with electrocardiogram recordings suitable for analysis, ST segment change was greater in the monophasic group (P=0.037). The Welch Allyn-MRL biphasic waveform for DC cardioversion results in fewer shocks, with less cumulative energy delivered and less post shock ST change than with a Hewlett Packard Codemaster XL damped sine wave monophasic waveform.
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.
Computer model analysis of the radial artery pressure waveform.
Schwid, H A; Taylor, L A; Smith, N T
1987-10-01
Simultaneous measurements of aortic and radial artery pressures are reviewed, and a model of the cardiovascular system is presented. The model is based on resonant networks for the aorta and axillo-brachial-radial arterial system. The model chosen is a simple one, in order to make interpretation of the observed relationships clear. Despite its simplicity, the model produces realistic aortic and radial artery pressure waveforms. It demonstrates that the resonant properties of the arterial wall significantly alter the pressure waveform as it is propagated from the aorta to the radial artery. Although the mean and end-diastolic radial pressures are usually accurate estimates of the corresponding aortic pressures, the systolic pressure at the radial artery is often much higher than that of the aorta due to overshoot caused by the resonant behavior of the radial artery. The radial artery dicrotic notch is predominantly dependent on the axillo-brachial-radial arterial wall properties, rather than on the aortic valve or peripheral resistance. Hence the use of the radial artery dicrotic notch as an estimate of end systole is unreliable. The rate of systolic upstroke, dP/dt, of the radial artery waveform is a function of many factors, making it difficult to interpret. The radial artery waveform usually provides accurate estimates for mean and diastolic aortic pressures; for all other measurements it is an inadequate substitute for the aortic pressure waveform. In the presence of low forearm peripheral resistance the mean radial artery pressure may significantly underestimate the mean aortic pressure, as explained by a voltage divider model.
Impact of Major Pulmonary Resections on Right Ventricular Function: Early Postoperative Changes.
Elrakhawy, Hany M; Alassal, Mohamed A; Shaalan, Ayman M; Awad, Ahmed A; Sayed, Sameh; Saffan, Mohammad M
2018-01-15
Right ventricular (RV) dysfunction after pulmonary resection in the early postoperative period is documented by reduced RV ejection fraction and increased RV end-diastolic volume index. Supraventricular arrhythmia, particularly atrial fibrillation, is common after pulmonary resection. RV assessment can be done by non-invasive methods and/or invasive approaches such as right cardiac catheterization. Incorporation of a rapid response thermistor to pulmonary artery catheter permits continuous measurements of cardiac output, right ventricular ejection fraction, and right ventricular end-diastolic volume. It can also be used for right atrial and right ventricular pacing, and for measuring right-sided pressures, including pulmonary capillary wedge pressure. This study included 178 patients who underwent major pulmonary resections, 36 who underwent pneumonectomy assigned as group (I) and 142 who underwent lobectomy assigned as group (II). The study was conducted at the cardiothoracic surgery department of Benha University hospital in Egypt; patients enrolled were operated on from February 2012 to February 2016. A rapid response thermistor pulmonary artery catheter was inserted via the right internal jugular vein. Preoperatively the following was recorded: central venous pressure, mean pulmonary artery pressure, pulmonary capillary wedge pressure, cardiac output, right ventricular ejection fraction and volumes. The same parameters were collected in fixed time intervals after 3 hours, 6 hours, 12 hours, 24 hours, and 48 hours postoperatively. For group (I): There were no statistically significant changes between the preoperative and postoperative records in the central venous pressure and mean arterial pressure; there were no statistically significant changes in the preoperative and 12, 24, and 48 hour postoperative records for cardiac index; 3 and 6 hours postoperative showed significant changes. There were statistically significant changes between the preoperative and postoperative records for heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction and right ventricular end diastolic volume index, in all postoperative records. For group (II): There were no statistically significant changes between the preoperative and all postoperative records for the central venous pressure, mean arterial pressure and cardiac index. There were statistically significant changes between the preoperative and postoperative records for heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction and right ventricular end diastolic volume index in all postoperative records. There were statistically significant changes between the two groups in all postoperative records for heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction and right ventricular end diastolic volume index. There is right ventricular dysfunction early after major pulmonary resection caused by increased right ventricular afterload. This dysfunction is more present in pneumonectomy than in lobectomy. Heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction, and right ventricular end diastolic volume index are significantly affected by pulmonary resection.
Aston, Philip J; Christie, Mark I; Huang, Ying H; Nandi, Manasi
2018-03-01
Advances in monitoring technology allow blood pressure waveforms to be collected at sampling frequencies of 250-1000 Hz for long time periods. However, much of the raw data are under-analysed. Heart rate variability (HRV) methods, in which beat-to-beat interval lengths are extracted and analysed, have been extensively studied. However, this approach discards the majority of the raw data. Our aim is to detect changes in the shape of the waveform in long streams of blood pressure data. Our approach involves extracting key features from large complex data sets by generating a reconstructed attractor in a three-dimensional phase space using delay coordinates from a window of the entire raw waveform data. The naturally occurring baseline variation is removed by projecting the attractor onto a plane from which new quantitative measures are obtained. The time window is moved through the data to give a collection of signals which relate to various aspects of the waveform shape. This approach enables visualisation and quantification of changes in the waveform shape and has been applied to blood pressure data collected from conscious unrestrained mice and to human blood pressure data. The interpretation of the attractor measures is aided by the analysis of simple artificial waveforms. We have developed and analysed a new method for analysing blood pressure data that uses all of the waveform data and hence can detect changes in the waveform shape that HRV methods cannot, which is confirmed with an example, and hence our method goes 'beyond HRV'.
Aston, Philip J; Christie, Mark I; Huang, Ying H; Nandi, Manasi
2018-01-01
Abstract Advances in monitoring technology allow blood pressure waveforms to be collected at sampling frequencies of 250–1000 Hz for long time periods. However, much of the raw data are under-analysed. Heart rate variability (HRV) methods, in which beat-to-beat interval lengths are extracted and analysed, have been extensively studied. However, this approach discards the majority of the raw data. Objective: Our aim is to detect changes in the shape of the waveform in long streams of blood pressure data. Approach: Our approach involves extracting key features from large complex data sets by generating a reconstructed attractor in a three-dimensional phase space using delay coordinates from a window of the entire raw waveform data. The naturally occurring baseline variation is removed by projecting the attractor onto a plane from which new quantitative measures are obtained. The time window is moved through the data to give a collection of signals which relate to various aspects of the waveform shape. Main results: This approach enables visualisation and quantification of changes in the waveform shape and has been applied to blood pressure data collected from conscious unrestrained mice and to human blood pressure data. The interpretation of the attractor measures is aided by the analysis of simple artificial waveforms. Significance: We have developed and analysed a new method for analysing blood pressure data that uses all of the waveform data and hence can detect changes in the waveform shape that HRV methods cannot, which is confirmed with an example, and hence our method goes ‘beyond HRV’. PMID:29350622
Bovendeerd, Peter H M; Borsje, Petra; Arts, Theo; van De Vosse, Frans N
2006-12-01
The phasic coronary arterial inflow during the normal cardiac cycle has been explained with simple (waterfall, intramyocardial pump) models, emphasizing the role of ventricular pressure. To explain changes in isovolumic and low afterload beats, these models were extended with the effect of three-dimensional wall stress, nonlinear characteristics of the coronary bed, and extravascular fluid exchange. With the associated increase in the number of model parameters, a detailed parameter sensitivity analysis has become difficult. Therefore we investigated the primary relations between ventricular pressure and volume, wall stress, intramyocardial pressure and coronary blood flow, with a mathematical model with a limited number of parameters. The model replicates several experimental observations: the phasic character of coronary inflow is virtually independent of maximum ventricular pressure, the amplitude of the coronary flow signal varies about proportionally with cardiac contractility, and intramyocardial pressure in the ventricular wall may exceed ventricular pressure. A parameter sensitivity analysis shows that the normalized amplitude of coronary inflow is mainly determined by contractility, reflected in ventricular pressure and, at low ventricular volumes, radial wall stress. Normalized flow amplitude is less sensitive to myocardial coronary compliance and resistance, and to the relation between active fiber stress, time, and sarcomere shortening velocity.
Pahlevan, Niema M.; Tavallali, Peyman; Rinderknecht, Derek G.; Petrasek, Danny; Matthews, Ray V.; Hou, Thomas Y.; Gharib, Morteza
2014-01-01
The reductionist approach has dominated the fields of biology and medicine for nearly a century. Here, we present a systems science approach to the analysis of physiological waveforms in the context of a specific case, cardiovascular physiology. Our goal in this study is to introduce a methodology that allows for novel insight into cardiovascular physiology and to show proof of concept for a new index for the evaluation of the cardiovascular system through pressure wave analysis. This methodology uses a modified version of sparse time–frequency representation (STFR) to extract two dominant frequencies we refer to as intrinsic frequencies (IFs; ω1 and ω2). The IFs are the dominant frequencies of the instantaneous frequency of the coupled heart + aorta system before the closure of the aortic valve and the decoupled aorta after valve closure. In this study, we extract the IFs from a series of aortic pressure waves obtained from both clinical data and a computational model. Our results demonstrate that at the heart rate at which the left ventricular pulsatile workload is minimized the two IFs are equal (ω1 = ω2). Extracted IFs from clinical data indicate that at young ages the total frequency variation (Δω = ω1 − ω2) is close to zero and that Δω increases with age or disease (e.g. heart failure and hypertension). While the focus of this paper is the cardiovascular system, this approach can easily be extended to other physiological systems or any biological signal. PMID:25008087
Advanced life systems hardware development for future missions
NASA Technical Reports Server (NTRS)
1975-01-01
An examination of the pulse formation in an externalized vessel suggests that the vessel does not behave as a simple visco-elastic tube. Pressure-pulse waveform transducers are sensitive either to the pressure present at the vessel wall or to the volume of blood filling a region of tissue. Results of comparisons between intra-and extra-vascular pressure recordings suggest that changes in vasomotor tone and transducer-vessel pressures may be the greatest contributors to the divergence of extra-vascular waveforms from intra-vascular waveforms.
Wavelet analysis of the impedance cardiogram waveforms
NASA Astrophysics Data System (ADS)
Podtaev, S.; Stepanov, R.; Dumler, A.; Chugainov, S.; Tziberkin, K.
2012-12-01
Impedance cardiography has been used for diagnosing atrial and ventricular dysfunctions, valve disorders, aortic stenosis, and vascular diseases. Almost all the applications of impedance cardiography require determination of some of the characteristic points of the ICG waveform. The ICG waveform has a set of characteristic points known as A, B, E ((dZ/dt)max) X, Y, O and Z. These points are related to distinct physiological events in the cardiac cycle. Objective of this work is an approbation of a new method of processing and interpretation of the impedance cardiogram waveforms using wavelet analysis. A method of computer thoracic tetrapolar polyrheocardiography is used for hemodynamic registrations. Use of original wavelet differentiation algorithm allows combining filtration and calculation of the derivatives of rheocardiogram. The proposed approach can be used in clinical practice for early diagnostics of cardiovascular system remodelling in the course of different pathologies.
NASA Astrophysics Data System (ADS)
Schiavone, Nicole; Elkins, Christopher; McElhinney, Doff; Eaton, John K.; Marsden, Alison
2017-11-01
Tetralogy of Fallot (ToF), the most common type of cyanotic congenital heart defect, affects 1 in every 2500 newborns annually and typically requires surgical repair of the right ventricular outflow tract (RVOT) and placement of an artificial pulmonary valve. All artificial valves are subject to dysfunction, but their longevity is highly variable. Clinical observation reveals large variations in RVOT anatomy in ToF patients, which may affect longevity. This work aims to experimentally assess the performance of artificial pulmonary valves in anatomically realistic healthy and diseased RVOT geometries using magnetic resonance velocimetry (MRV). With MRV, we can capture 3D, three-component, phase-averaged velocity fields in 3D printed RVOT geometries. The experiment is designed to ensure physiological flow rate and pressure waveforms, while the RVOT geometries are based on anatomies seen clinically in ToF patients. Two models are used in the current work: an idealized RVOT based on healthy subjects aged eleven to thirteen and a diseased geometry with a dilation of 150% in vessel diameter downstream of the pulmonary valve. We will also present preliminary rigid-wall blood flow simulations in each model, towards the ultimate goal of experimental validation of valve simulations.
Use of paravascular admittance waveforms to monitor relative change in arterial blood pressure
NASA Astrophysics Data System (ADS)
Zielinski, Todd M.; Hettrick, Doug; Cho, Yong
2010-04-01
Non-invasive methods to monitor ambulatory blood pressure often have limitations that can affect measurement accuracy and patient adherence [1]. Minimally invasive measurement of a relative blood pressure surrogate with an implantable device may provide a useful chronic diagnostic and monitoring tool. We assessed a technique that uses electrocardiogram and paravascular admittance waveform morphology analysis to one, measure a time duration (vascular tone index, VTI in milliseconds) change from the electrocardiogram R-wave to admittance waveform peak and two, measure the admittance waveform minimum, maximum and magnitude as indicators of change in arterial compliance/distensibility or pulse pressure secondary to change in afterload. Methods: Five anesthetized domestic pigs (32 ± 4.2 kg) were used to study the effects of phenylephrine (1-5 ug/kg/min) on femoral artery pressure and admittance waveform morphology measured with a quadrapolar electrode array catheter placed next to the femoral artery to assess the relative change in arterial compliance due to change in peripheral vascular tone. Results: Statistical difference was observed (p < 0.05) comparing baseline VTI to phenylephrine VTI (246 ± .05 ms to 320 ± .07 ms) and baseline admittance waveform maximum to phenylephrine admittance waveform maximum (0.0148 ± .002 siemens to 0.0151 ± .002 siemens). Conclusion: Chronic minimally invasive admittance measurement techniques that monitor relative change in blood pressure may be suitable for implantable devices to detect progression of cardiovascular disease such as hypertension.
Fong, Allan; Mittu, Ranjeev; Ratwani, Raj; Reggia, James
2014-01-01
Alarm fatigue caused by false alarms and alerts is an extremely important issue for the medical staff in Intensive Care Units. The ability to predict electrocardiogram and arterial blood pressure waveforms can potentially help the staff and hospital systems better classify a patient's waveforms and subsequent alarms. This paper explores the use of Echo State Networks, a specific type of neural network for mining, understanding, and predicting electrocardiogram and arterial blood pressure waveforms. Several network architectures are designed and evaluated. The results show the utility of these echo state networks, particularly ones with larger integrated reservoirs, for predicting electrocardiogram waveforms and the adaptability of such models across individuals. The work presented here offers a unique approach for understanding and predicting a patient's waveforms in order to potentially improve alarm generation. We conclude with a brief discussion of future extensions of this research.
Bonnemain, Jean; Malossi, A Cristiano I; Lesinigo, Matteo; Deparis, Simone; Quarteroni, Alfio; von Segesser, Ludwig K
2013-10-01
In this work we present numerical simulations of continuous flow left ventricle assist device implantation with the aim of comparing difference in flow rates and pressure patterns depending on the location of the anastomosis and the rotational speed of the device. Despite the fact that the descending aorta anastomosis approach is less invasive, since it does not require a sternotomy and a cardiopulmonary bypass, its benefits are still controversial. Moreover, the device rotational speed should be correctly chosen to avoid anomalous flow rates and pressure distribution in specific location of the cardiovascular tree. With the aim of assessing the differences between these two approaches and device rotational speed in terms of flow rate and pressure waveforms, we set up numerical simulations of network of one-dimensional models where we account for the presence of an outflow cannula anastomosed to different locations of the aorta. Then, we use the resulting network to compare the results of the two different cannulations for several stages of heart failure and different rotational speed of the device. The inflow boundary data for the heart and the cannulas are obtained from a lumped parameters model of the entire circulatory system with an assist device, which is validated with clinical data. The results show that ascending and descending aorta cannulations lead to similar waveforms and mean flow rate in all the considered cases. Moreover, regardless of the anastomosis region, the rotational speed of the device has an important impact on wave profiles; this effect is more pronounced at high RPM. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
Left ventricular pressure and volume data acquisition and analysis using LabVIEW.
Cassidy, S C; Teitel, D F
1997-03-01
To automate analysis of left ventricular pressure-volume data, we used LabVIEW to create applications that digitize and display data recorded from conductance and manometric catheters. Applications separate data into cardiac cycles, calculate parallel conductance, and calculate indices of left ventricular function, including end-systolic elastance, preload-recruitable stroke work, stroke volume, ejection fraction, stroke work, maximum and minimum derivative of ventricular pressure, heart rate, indices of relaxation, peak filling rate, and ventricular chamber stiffness. Pressure-volume loops can be graphically displayed. These analyses are exported to a text-file. These applications have simplified and automated the process of evaluating ventricular function.
DeMarzo, Arthur P
2013-06-01
Early detection of cardiovascular disease (CVD) in prehypertension could initiate appropriate treatment and prevent progression. Impedance cardiography (ICG) is a noninvasive technology that can be used to assess cardiovascular function. This study used ICG waveform analysis with postural change to detect CVD in asymptomatic prehypertensive adults over 40 years of age with no history of CVD and at least 2 cardiovascular risk factors: cigarette smoking, poor diet, physical inactivity, central obesity, family history of premature CVD, elevated blood glucose, and dyslipidemia. A study group of 25 apparently healthy adults was tested by ICG in standing and supine positions. Criteria for an age-matched control group of 16 healthy subjects included an active lifestyle, no risk factor, and no history of CVD. In addition to hemodynamic measurements of systemic vascular resistance (SVR) and cardiac index (CI), ICG used SVR to assess vascular resistive load, an index of arterial compliance and a widening of the systolic waveform to assess vascular pulsatile load, and waveform analysis and measured wave amplitude to detect ventricular dysfunction. All subjects in the study group had some abnormal ICG data, with an average of 2.9 ± 1.5 abnormalities per person. ICG indicated that 24 (96%) had elevated vascular load, 13 (52%) had some type of ventricular dysfunction, and 12 (48%) had abnormal hemodynamics. For the control group, ICG showed none (0%) with elevated vascular load, none (0%) with ventricular dysfunction, and 7 (44%) with high CI. Prehypertensives over 40 years of age with multiple risk factors have different cardiovascular abnormalities. This ICG test could be used as part of a prevention program for early detection of CVD. An abnormal ICG test could expedite the initiation of customized treatment that targets the subclinical CVD.
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.
Bonnet, Benjamin; Jourdan, Franck; du Cailar, Guilhem; Fesler, Pierre
2017-08-01
End-systolic left ventricular (LV) elastance ( E es ) has been previously calculated and validated invasively using LV pressure-volume (P-V) loops. Noninvasive methods have been proposed, but clinical application remains complex. The aims of the present study were to 1 ) estimate E es according to modeling of the LV P-V curve during ejection ("ejection P-V curve" method) and validate our method with existing published LV P-V loop data and 2 ) test the clinical applicability of noninvasively detecting a difference in E es between normotensive and hypertensive subjects. On the basis of the ejection P-V curve and a linear relationship between elastance and time during ejection, we used a nonlinear least-squares method to fit the pressure waveform. We then computed the slope and intercept of time-varying elastance as well as the volume intercept (V 0 ). As a validation, 22 P-V loops obtained from previous invasive studies were digitized and analyzed using the ejection P-V curve method. To test clinical applicability, ejection P-V curves were obtained from 33 hypertensive subjects and 32 normotensive subjects with carotid tonometry and real-time three-dimensional echocardiography during the same procedure. A good univariate relationship ( r 2 = 0.92, P < 0.005) and good limits of agreement were found between the invasive calculation of E es and our new proposed ejection P-V curve method. In hypertensive patients, an increase in arterial elastance ( E a ) was compensated by a parallel increase in E es without change in E a / E es In addition, the clinical reproducibility of our method was similar to that of another noninvasive method. In conclusion, E es and V 0 can be estimated noninvasively from modeling of the P-V curve during ejection. This approach was found to be reproducible and sensitive enough to detect an expected increase in LV contractility in hypertensive patients. Because of its noninvasive nature, this methodology may have clinical implications in various disease states. NEW & NOTEWORTHY The use of real-time three-dimensional echocardiography-derived left ventricular volumes in conjunction with carotid tonometry was found to be reproducible and sensitive enough to detect expected differences in left ventricular elastance in arterial hypertension. Because of its noninvasive nature, this methodology may have clinical implications in various disease states. Copyright © 2017 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Sharath, Umesh; Sukreet, Raju; Apoorva, Girish; Asokan, Sundarrajan
2013-06-01
We report a blood pressure evaluation methodology by recording the radial arterial pulse waveform in real time using a fiber Bragg grating pulse device (FBGPD). Here, the pressure responses of the arterial pulse in the form of beat-to-beat pulse amplitude and arterial diametrical variations are monitored. Particularly, the unique signatures of pulse pressure variations have been recorded in the arterial pulse waveform, which indicate the systolic and diastolic blood pressure while the patient is subjected to the sphygmomanometric blood pressure examination. The proposed method of blood pressure evaluation using FBGPD has been validated with the auscultatory method of detecting the acoustic pulses (Korotkoff sounds) by an electronic stethoscope.
Borsje, Petra; Arts, Theo; van De Vosse, Frans N.
2006-01-01
The phasic coronary arterial inflow during the normal cardiac cycle has been explained with simple (waterfall, intramyocardial pump) models, emphasizing the role of ventricular pressure. To explain changes in isovolumic and low afterload beats, these models were extended with the effect of three-dimensional wall stress, nonlinear characteristics of the coronary bed, and extravascular fluid exchange. With the associated increase in the number of model parameters, a detailed parameter sensitivity analysis has become difficult. Therefore we investigated the primary relations between ventricular pressure and volume, wall stress, intramyocardial pressure and coronary blood flow, with a mathematical model with a limited number of parameters. The model replicates several experimental observations: the phasic character of coronary inflow is virtually independent of maximum ventricular pressure, the amplitude of the coronary flow signal varies about proportionally with cardiac contractility, and intramyocardial pressure in the ventricular wall may exceed ventricular pressure. A parameter sensitivity analysis shows that the normalized amplitude of coronary inflow is mainly determined by contractility, reflected in ventricular pressure and, at low ventricular volumes, radial wall stress. Normalized flow amplitude is less sensitive to myocardial coronary compliance and resistance, and to the relation between active fiber stress, time, and sarcomere shortening velocity. PMID:17048105
Moller, Thomas; Lindberg, Harald; Lund, May Brit; Holmstrom, Henrik; Dohlen, Gaute; Thaulow, Erik
2018-06-01
We previously demonstrated an abnormally high right ventricular systolic pressure response to exercise in 50% of adolescents operated on for isolated ventricular septal defect. The present study investigated the prevalence of abnormal right ventricular systolic pressure response in 20 adult (age 30-45 years) patients who underwent surgery for early ventricular septal defect closure and its association with impaired ventricular function, pulmonary function, or exercise capacity. The patients underwent cardiopulmonary tests, including exercise stress echocardiography. Five of 19 patients (26%) presented an abnormal right ventricular systolic pressure response to exercise ⩾ 52 mmHg. Right ventricular systolic function was mixed, with normal tricuspid annular plane systolic excursion and fractional area change, but abnormal tricuspid annular systolic motion velocity (median 6.7 cm/second) and isovolumetric acceleration (median 0.8 m/second2). Left ventricular systolic and diastolic function was normal at rest as measured by the peak systolic velocity of the lateral wall and isovolumic acceleration, early diastolic velocity, and ratio of early diastolic flow to tissue velocity, except for ejection fraction (median 53%). The myocardial performance index was abnormal for both the left and right ventricle. Peak oxygen uptake was normal (mean z score -0.4, 95% CI -2.8-0.3). There was no association between an abnormal right ventricular systolic pressure response during exercise and right or left ventricular function, pulmonary function, or exercise capacity. Abnormal right ventricular pressure response is not more frequent in adult patients compared with adolescents. This does not support the theory of progressive pulmonary vascular disease following closure of left-to-right shunts.
Kamoi, S; Pretty, C G; Chiew, Y S; Pironet, A; Davidson, S; Desaive, T; Shaw, G M; Chase, J G
2015-08-01
Accurate Stroke Volume (SV) monitoring is essential for patient with cardiovascular dysfunction patients. However, direct SV measurements are not clinically feasible due to the highly invasive nature of measurement devices. Current devices for indirect monitoring of SV are shown to be inaccurate during sudden hemodynamic changes. This paper presents a novel SV estimation using readily available aortic pressure measurements and aortic cross sectional area, using data from a porcine experiment where medical interventions such as fluid replacement, dobutamine infusions, and recruitment maneuvers induced SV changes in a pig with circulatory shock. Measurement of left ventricular volume, proximal aortic pressure, and descending aortic pressure waveforms were made simultaneously during the experiment. From measured data, proximal aortic pressure was separated into reservoir and excess pressures. Beat-to-beat aortic characteristic impedance values were calculated using both aortic pressure measurements and an estimate of the aortic cross sectional area. SV was estimated using the calculated aortic characteristic impedance and excess component of the proximal aorta. The median difference between directly measured SV and estimated SV was -1.4ml with 95% limit of agreement +/- 6.6ml. This method demonstrates that SV can be accurately captured beat-to-beat during sudden changes in hemodynamic state. This novel SV estimation could enable improved cardiac and circulatory treatment in the critical care environment by titrating treatment to the effect on SV.
Weber, Thomas; Wassertheurer, Siegfried; Schmidt-Trucksäss, Arno; Rodilla, Enrique; Ablasser, Cornelia; Jankowski, Piotr; Lorenza Muiesan, Maria; Giannattasio, Cristina; Mang, Claudia; Wilkinson, Ian; Kellermair, Jörg; Hametner, Bernhard; Pascual, Jose Maria; Zweiker, Robert; Czarnecka, Danuta; Paini, Anna; Salvetti, Massimo; Maloberti, Alessandro; McEniery, Carmel
2017-12-01
We investigated the relationship between left ventricular mass and brachial office as well as brachial and central ambulatory systolic blood pressure in 7 European centers. Central systolic pressure was measured with a validated oscillometric device, using a transfer function, and mean/diastolic pressure calibration. M-mode images were obtained by echocardiography, and left ventricular mass was determined by one single reader blinded to blood pressure. We studied 289 participants (137 women) free from antihypertensive drugs (mean age: 50.8 years). Mean office blood pressure was 145/88 mm Hg and mean brachial and central ambulatory systolic pressures were 127 and 128 mm Hg, respectively. Mean left ventricular mass was 93.3 kg/m 2 , and 25.6% had left ventricular hypertrophy. The correlation coefficient between left ventricular mass and brachial office, brachial ambulatory, and central ambulatory systolic pressure was 0.29, 0.41, and 0.47, respectively ( P =0.003 for comparison between brachial office and central ambulatory systolic pressure and 0.32 for comparison between brachial and central ambulatory systolic pressure). The results were consistent for men and women, and young and old participants. The areas under the curve for prediction of left ventricular hypertrophy were 0.618, 0.635, and 0.666 for brachial office, brachial, and central ambulatory systolic pressure, respectively ( P =0.03 for comparison between brachial and central ambulatory systolic pressure). In younger participants, central ambulatory systolic pressure was superior to both other measurements. Central ambulatory systolic pressure, measured with an oscillometric cuff, shows a strong trend toward a closer association with left ventricular mass and hypertrophy than brachial office/ambulatory systolic pressure. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01278732. © 2017 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Ermishkin, V. V.; Kolesnikov, V. A.; Lukoshkova, E. V.; Sonina, R. S.
2013-04-01
The impedance cardiography (ICG) is widely used for beat-to-beat noninvasive evaluation of the left ventricular stroke volume and contractility. It implies the correct determination of the ejection start and end points and the amplitudes of certain peaks in the differentiated impedance cardiogram. An accurate identification of ejection onset by ICG is often problematic, especially in the cardiologic patients, due to peculiar waveforms. Using a simple theoretical model, we tested the hypothesis that two major processes are responsible for the formation of impedance systolic wave: (1) the changes in the heart geometry and surrounding vessels produced by ventricular contraction, which occur during the isovolumic phase and precede ejection, and (2) expansion of aorta and adjacent arteries during the ejection phase. The former process initiates the preejection wave WpE and the latter triggers the ejection wave WEj. The model predicts a potential mechanism of generating the abnormal shapes of dZ/dt due to the presence of preejection waves and explains the related errors in ICG time and amplitude parameters. An appropriate decomposition method is a promising way to avoid the masking effects of these waves and a further step to correct determination of the onset of ejection and the corresponding peak amplitudes from 'pathologically shaped' ICG signals.
Tanabe, Seizan; Yasunaga, Hideo; Ogawa, Toshio; Koike, Soichi; Akahane, Manabu; Horiguchi, Hiromasa; Hatanaka, Tetsuo; Yokota, Hiroyuki; Imamura, Tomoaki
2012-09-01
The use and popularity of the biphasic waveform defibrillator as a replacement for the monophasic waveform defibrillator are increasing, but it is unclear whether this can improve the rate of survival among out-of-hospital cardiac arrest patients. This study aimed to verify the hypothesis that the outcome of out-of-hospital cardiac arrest patients who received defibrillation shock with the biphasic waveform defibrillator was better than that of patients who received defibrillation shock with the monophasic defibrillator. This prospective, nationwide, population-based, observational study included 21 172 out-of-hospital cardiac arrest patients with initial ventricular fibrillation or pulseless ventricular tachycardia from January 1, 2005, through December 31, 2007. Defibrillation shock was performed by monophasic defibrillator on 8224 (39%) patients and by biphasic defibrillator on 12 948 (61%) patients. The rate of survival at 1 month with minimal neurological impairment was 11.6% (951/8192) in the monophasic defibrillator group and 12.8% (1653/12 928) in the biphasic defibrillator group. Hierarchical logistic regression analysis using a generalized estimation equation showed no significant difference between the biphasic and monophasic groups in 1-month survival with minimal neurological impairment (adjusted odds ratio, 1.07; 95% confidence interval, 0.91-1.26; P=0.42). Confirmatory propensity score analyses showed similar results. Although monophasic defibrillators are being replaced by biphasic defibrillators, our nationwide population-based observational study failed to demonstrate a statistically significant association between defibrillation waveform and 1-month survival rate with minimal neurological impairment.
Sun, Chenglu; Li, Wei; Chen, Wei
2017-01-01
For extracting the pressure distribution image and respiratory waveform unobtrusively and comfortably, we proposed a smart mat which utilized a flexible pressure sensor array, printed electrodes and novel soft seven-layer structure to monitor those physiological information. However, in order to obtain high-resolution pressure distribution and more accurate respiratory waveform, it needs more time to acquire the pressure signal of all the pressure sensors embedded in the smart mat. In order to reduce the sampling time while keeping the same resolution and accuracy, a novel method based on compressed sensing (CS) theory was proposed. By utilizing the CS based method, 40% of the sampling time can be decreased by means of acquiring nearly one-third of original sampling points. Then several experiments were carried out to validate the performance of the CS based method. While less than one-third of original sampling points were measured, the correlation degree coefficient between reconstructed respiratory waveform and original waveform can achieve 0.9078, and the accuracy of the respiratory rate (RR) extracted from the reconstructed respiratory waveform can reach 95.54%. The experimental results demonstrated that the novel method can fit the high resolution smart mat system and be a viable option for reducing the sampling time of the pressure sensor array. PMID:28796188
[Blood pressure variability and left ventricular hypertrophy in arterial hypertension].
Amodeo, C; Martins, S M; Silva Júnior, O; Barros, L M; Batlouni, M; Sousa, J E
1993-05-01
To evaluate the left ventricular hypertrophy correlation with blood pressure variability during day and night time as well as throughout the 24h period. Fifteen patients with mild to moderate essential hypertension underwent to bi-dimensional echocardiographic study and to 24h ambulatory blood pressure monitorization. Left ventricular mass was calculated according to previous validated formulas. The standard deviation of the mean blood pressures during day-time, night-time and 24h period was taken as blood pressure variability indices. The mean age of the group was 42 years old; 9 patients were male and all were white. This study showed that only the systolic and diastolic blood pressure variability during the 24h period correlated significantly with left ventricular mass, (r = 0.53 and p < 0.05; r = 0.58 and p < 0.05 respectively). There was no significant correlation of the day-time and night-time pressures variability with left ventricular mass. The systolic and diastolic blood pressure variability during the 24h period may be one of the many determinants of left ventricular hypertrophy in patients with mild to moderate hypertension.
Skrzypczak, P; Zyśko, D; Pasławska, U; Noszczyk-Nowak, A; Janiszewski, A; Gajek, J; Nicpoń, J; Kiczak, L; Bania, J; Zacharski, M; Tomaszek, A; Jankowska, E A; Ponikowski, P; Witkiewicz, W
2014-01-01
Ventricular tachycardia may lead to haemodynamic deterioration and, in the case of long term persistence, is associated with the development of tachycardiomyopathy. The effect of ventricular tachycardia on haemodynamics in individuals with tachycardiomyopathy, but being in sinus rhythm has not been studied. Rapid ventricular pacing is a model of ventricular tachycardia. The aim of this study was to determine the effect of rapid ventricular pacing on blood pressure in healthy animals and those with tachycardiomyopathy. A total of 66 animals were studied: 32 in the control group and 34 in the study group. The results of two groups of examinations were compared: the first performed in healthy animals (133 examinations) and the second performed in animals paced for at least one month (77 examinations). Blood pressure measurements were taken during chronic pacing--20 min after onset of general anaesthesia, in baseline conditions (20 min after pacing cessation or 20 min after onset of general anaesthesia in healthy animals) and immediately after short-term rapid pacing. In baseline conditions significantly higher systolic and diastolic blood pressure was found in healthy animals than in those with tachycardiomyopathy. During an event of rapid ventricular pacing, a significant decrease in systolic and diastolic blood pressure was found in both groups of animals. In the group of chronically paced animals the blood pressure was lower just after restarting ventricular pacing than during chronic pacing. Cardiovascular adaptation to ventricular tachycardia develops with the length of its duration. Relapse of ventricular tachycardia leads to a blood pressure decrease more pronounced than during chronic ventricular pacing.
Compressed storage of arterial pressure waveforms by selection of significant points.
de Graaf, P M; van Goudoever, J; Wesseling, K H
1997-09-01
Continuous records of arterial blood pressure can be obtained non-invasively with Finapres, even for periods of 24 hours. Increasingly, storage of such records is done digitally, requiring large disc capacities. It is therefore necessary to find methods to store blood pressure waveforms in compressed form. The method of selection of significant points known from ECG data compression is adapted. Points are selected as significant wherever the first derivative of the pressure wave changes sign. As a second stage recursive partitioning is used to select additional points such that the difference between the selected points, linearly interpolated, and the original curve remains below a maximum. This method is tested on finger arterial pressure waveform epochs of 60 s duration taken from 32 patients with a wide range of blood pressures and heart rates. An average compression factor of 4.6 (SD 1.0) is obtained when accepting a maximum difference of 3 mmHg. The root mean squared error is 1 mmHg averaged over the group of patient waveforms. Clinically relevant parameters such as systolic, diastolic and mean pressure are reproduced with an offset error of less than 0.5 (0.3) mmHg and scatter less than 0.6 (0.1) mmHg. It is concluded that a substantial compression factor can be achieved with a simple and computationally fast algorithm and little deterioration in waveform quality and pressure level accuracy.
Hunter, Kendall S.; Lee, Po-Feng; Lanning, Craig J.; Ivy, D. Dunbar; Kirby, K. Scott; Claussen, Lori R.; Chan, K. Chen; Shandas, Robin
2011-01-01
Background Pulmonary vascular resistance (PVR) is the current standard for evaluating reactivity in children with pulmonary arterial hypertension (PAH). However, PVR measures only the mean component of right ventricular afterload and neglects pulsatile effects. We recently developed and validated an method to measure pulmonary vascular input impedance, which revealed excellent correlation between the zero-harmonic impedance value and PVR, and suggested a correlation between higher harmonic impedance values and pulmonary vascular stiffness (PVS). Here we show that input impedance can be measured routinely and easily in the catheterization laboratory, that impedance provides PVR and PVS from a single measurement, and that impedance is a better predictor of disease outcomes compared to PVR. Methods Pressure and velocity waveforms within the main PA were measured during right-heart catheterization of patients with normal PA hemodynamics (n=14) and those with PAH undergoing reactivity evaluation (49 subjects; 95 conditions). A correction factor needed to transform velocity into flow was obtained by calibrating against cardiac output. Input impedance was obtained off-line by dividing Fourier-transformed pressure and flow waveforms. Results Exceptional correlation was found between the indexed zero harmonic of impedance and indexed PVR (y=1.095·x+1.381, R2=0.9620). Additionally, the modulus sum of the first two harmonics of impedance was found to best correlate with indexed pulse pressure over stroke volume (PP/SV) (y=13.39·x-0.8058, R2=0.7962). Amongst a subset of PAH patients (n=25), cumulative logistic regression between outcomes to total indexed impedance was better (RL2=0.4012) than between outcomes and indexed PVR (RL2=0.3131). Conclusions Input impedance can be consistently and easily obtained from PW Doppler and a single catheter pressure measurement, provides comprehensive characterization of the main components of RV afterload, and better predicts patient outcomes compared to PVR alone. PMID:18082509
Hunter, Kendall S; Lee, Po-Feng; Lanning, Craig J; Ivy, D Dunbar; Kirby, K Scott; Claussen, Lori R; Chan, K Chen; Shandas, Robin
2008-01-01
Pulmonary vascular resistance (PVR) is the current standard for evaluating reactivity in children with pulmonary arterial hypertension (PAH). However, PVR measures only the mean component of right ventricular afterload and neglects pulsatile effects. We recently developed and validated a method to measure pulmonary vascular input impedance, which revealed excellent correlation between the zero harmonic impedance value and PVR and suggested a correlation between higher-harmonic impedance values and pulmonary vascular stiffness. Here we show that input impedance can be measured routinely and easily in the catheterization laboratory, that impedance provides PVR and pulmonary vascular stiffness from a single measurement, and that impedance is a better predictor of disease outcomes compared with PVR. Pressure and velocity waveforms within the main pulmonary artery were measured during right heart catheterization of patients with normal pulmonary artery hemodynamics (n = 14) and those with PAH undergoing reactivity evaluation (49 subjects, 95 conditions). A correction factor needed to transform velocity into flow was obtained by calibrating against cardiac output. Input impedance was obtained off-line by dividing Fourier-transformed pressure and flow waveforms. Exceptional correlation was found between the indexed zero harmonic of impedance and indexed PVR (y = 1.095x + 1.381, R2 = 0.9620). In addition, the modulus sum of the first 2 harmonics of impedance was found to best correlate with indexed pulse pressure over stroke volume (y = 13.39x - 0.8058, R2 = 0.7962). Among a subset of patients with PAH (n = 25), cumulative logistic regression between outcomes to total indexed impedance was better (R(L)2 = 0.4012) than between outcomes and indexed PVR (R(L)2 = 0.3131). Input impedance can be consistently and easily obtained from pulse-wave Doppler and a single catheter pressure measurement, provides comprehensive characterization of the main components of RV afterload, and better predicts patient outcomes compared with PVR alone.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhainaut, J.F.; Devaux, J.Y.; Monsallier, J.F.
1986-07-01
Continuous positive pressure ventilation is associated with a reduction in left ventricular preload and cardiac output, but the mechanisms responsible are controversial. The decrease in left ventricular preload may result exclusively from a decreased systemic venous return due to increased pleural pressure, or from an additional effect such as decreased left ventricular compliance. To determine the mechanisms responsible, we studied the changes in cardiac output induced by continuous positive pressure ventilation in eight patients with the adult respiratory distress syndrome. We measured cardiac output by thermodilution, and biventricular ejection fraction by equilibrium gated blood pool scintigraphy. Biventricular end-diastolic volumes weremore » then calculated by dividing stroke volume by ejection fraction. As positive end-expiratory pressure increased from 0 to 20 cm H/sub 2/O, stroke volume and biventricular end-diastolic volumes fell about 25 percent, and biventricular ejection fraction remained unchanged. At 20 cm H/sub 2/O positive end-expiratory pressure, volume expansion for normalizing cardiac output restored biventricular end-diastolic volumes without markedly changing biventricular end-diastolic transmural pressures. The primary cause of the reduction in left ventricular preload with continuous positive pressure ventilation appears to be a fall in venous return and hence in right ventricular stroke volume, without evidence of change in left ventricular diastolic compliance.« less
Herrmann, E; Fichtlscherer, S; Hohnloser, S H; Zeiher, A M; Aßmus, B
2016-12-01
Patients with advanced heart failure suffer from frequent hospitalizations. Non-invasive hemodynamic telemonitoring for assessment of ventricular filling pressure has been shown to reduce hospitalizations. We report on the right ventricular (RVP), the pulmonary artery (PAP) and the left atrial pressure (LAP) sensor for non-invasive assessment of the ventricular filling pressure. A literature search concerning the available implantable pressure sensors for noninvasive haemodynamic telemonitoring in patients with advanced heart failure was performed. Until now, only implantation of the PAP-sensor was able to reduce hospitalizations for cardiac decompensation and to improve quality of life. The right ventricular pressure sensor missed the primary endpoint of a significant reduction of hospitalizations, clinical data using the left atrial pressure sensor are still pending. The implantation of a pressure sensor for assessment of pulmonary artery filling pressure is suitable for reducing hospitalizations for heart failure and for improving quality of life in patients with advanced heart failure.
Flow-related Right Ventricular - Pulmonary Arterial Pressure Gradients during Exercise.
Wright, Stephen P; Opotowsky, Alexander R; Buchan, Tayler A; Esfandiari, Sam; Granton, John T; Goodman, Jack M; Mak, Susanna
2018-06-06
The assumption of equivalence between right ventricular and pulmonary arterial systolic pressure is fundamental to several assessments of right ventricular or pulmonary vascular hemodynamic function. Our aims were to 1) determine whether systolic pressure gradients develop across the right ventricular outflow tract in healthy adults during exercise, 2) examine the potential correlates of such gradients, and 3) consider the effect of such gradients on calculated indices of right ventricular function. Healthy untrained and endurance-trained adult volunteers were studied using right-heart catheterization at rest and during submaximal cycle ergometry. Right ventricular and pulmonary artery pressures were simultaneously transduced, and cardiac output was determined by thermodilution. Systolic pressures, peak and mean gradients, and indices of chamber, vascular, and valve function were analyzed offline. Summary data are reported as mean ± standard deviation or median [interquartile range]. No significant right ventricular outflow tract gradients were observed at rest (mean gradient = 4 [3-5] mmHg), and calculated effective orifice area was 3.6±1.0 cm2. Right ventricular systolic pressure increases during exercise were greater than that of pulmonary artery systolic pressure. Accordingly, mean gradients developed during light exercise (8 [7-9] mmHg) and increased during moderate exercise (12 [9-14] mmHg, p < 0.001). The magnitude of the mean gradient was linearly related to cardiac output (r2 = 0.70, p < 0.001). In healthy adults without pulmonic stenosis, systolic pressure gradients develop during exercise, and the magnitude is related to blood flow rate.
Piek, J; Raes, P
1996-01-01
We described a new ventricular catheter that is the combination of a "classic" ventricular catheter with a piezo-resistive transducer at its tip. The device allows parallel recordings of intraventricular fluid pressure via a chip and a fluid-filled external transducer, drainage of cerebrospinal fluid from the ventricle or injection of fluid into the ventricle with simultaneous monitoring of intracranial pressure, and recording of brain tissue pressure in cases of misplacement or dislocation of the ventricular catheter or in cases of progressively narrowing ventricles caused by brain edema. Clinical tests in various situations at different pressure ranges (total recording time, 1356 h in 13 patients) gave excellent correlations of both pressures. Application of the device is especially indicated in clinical situations in which pressure-controlled drainage is desirable, occlusion of ventricular bolts is likely, or pressure-volume tests are needed.
Circuit for detecting initial systole and dicrotic notch. [for monitoring arterial pressure
NASA Technical Reports Server (NTRS)
Gebben, V. D.; Webb, J. A., Jr. (Inventor)
1974-01-01
Circuitry is disclosed for processing an arterial pressure waveform to produce during any one cycle a pulse corresponding to the initial systole and a pulse corresponding to the dicrotic notch. In a first channel, an electrical analog of the arterial pressure waveform is filtered and then compared to the original waveform to produce an initial systole signal. In a second channel, the analog is differentiated, filtered, and fed through a gate controlled by pulses from the first channel to produce an electrical pulse corresponding to the dicrotic notch.
Kawaguchi, Y
1985-04-01
QRS deflection area vector (Aqrs), T deflection area vector (At) and ventricular gradient (G) in right ventricular hypertrophy were studied in 53 subjects divided on the basis of cardiac catheterization data into four subgroups; normal controls, mild MS group, right ventricular pressure overload group and right ventricular volume overload group. Aqrs, At and G of the four subgroups were calculated using a microcomputer and compared. Aqrs in right ventricular pressure overload group and volume overload group was shifted to the right and slightly anteriorly from that in normal control group. At in right ventricular pressure overload group and volume overload group was shifted slightly upwards and significantly posteriorly from that in the normal control and mild MS groups. G in right ventricular pressure overload group and volume overload group was shifted to the right and significantly posteriorly from that in normal control and mild MS groups. Using multivariative analysis, we developed criteria for diagnosing right ventricular hypertrophy with At: 0.059At(Z) - 0.0145 [At] - 0.2608 less than or equal to 0. Application of this criteria achieved 82.4% (28 of 34) sensitivity in the patients with right ventricular hypertrophy and 90.9% (10 of 11) specificity in the normal control subjects.
Use of the Kalman Filter for Aortic Pressure Waveform Noise Reduction
Lu, Hsiang-Wei; Wu, Chung-Che; Aliyazicioglu, Zekeriya; Kang, James S.
2017-01-01
Clinical applications that require extraction and interpretation of physiological signals or waveforms are susceptible to corruption by noise or artifacts. Real-time hemodynamic monitoring systems are important for clinicians to assess the hemodynamic stability of surgical or intensive care patients by interpreting hemodynamic parameters generated by an analysis of aortic blood pressure (ABP) waveform measurements. Since hemodynamic parameter estimation algorithms often detect events and features from measured ABP waveforms to generate hemodynamic parameters, noise and artifacts integrated into ABP waveforms can severely distort the interpretation of hemodynamic parameters by hemodynamic algorithms. In this article, we propose the use of the Kalman filter and the 4-element Windkessel model with static parameters, arterial compliance C, peripheral resistance R, aortic impedance r, and the inertia of blood L, to represent aortic circulation for generating accurate estimations of ABP waveforms through noise and artifact reduction. Results show the Kalman filter could very effectively eliminate noise and generate a good estimation from the noisy ABP waveform based on the past state history. The power spectrum of the measured ABP waveform and the synthesized ABP waveform shows two similar harmonic frequencies. PMID:28611850
A contemporary view of the ventricular gradient of Wilson.
Plonsey, R
1979-10-01
We have derived quantitative expressions for QRS, T, and QRST areas of the scalar electrocardiogram. The QRST area, or ventricular gradient, is seen to be essentially independent of the activation sequence and to reflect recovery properties of the tissue as weighted by the vector lead field of a given lead. The results are derived for uniform isotropic conditions and under the assumption that the temporal waveforms everywhere are identical except for possible variations in the duration of the plateau. However, it is noted that the results are, probably, valid under anisotropic conditions as well. The examination of ventricular gradients from epicardial and intramural leads should reflect local recovery properties and be a useful tool in study of the physiology of recovery, as well as the study of arrhythmias.
Elias, Merrill F; Sullivan, Lisa M; Elias, Penelope K; D'Agostino, Ralph B; Wolf, Philip A; Seshadri, Sudha; Au, Rhoda; Benjamin, Emelia J; Vasan, Ramachandran S
2007-03-01
The purpose of this study was to determine whether echocardiographic left ventricular mass is related to cognitive performance beyond casual blood pressure adjusting for the influence of other vascular risk factors. We used multivariable regression analyses to relate left ventricular mass assessed at a routine examination (1995-1998) to measures of cognitive ability obtained routinely (1998-2001) in 1673 Framingham Offspring Study participants (56% women; mean age: 57 years) free from stroke, transient ischemic attack, and dementia. We adjusted for the following covariates hierarchically: (1) age, education, sex, body weight, height, interval between left ventricular mass measurement and neuropsychological testing (basic model); (2) basic model+blood pressure+treatment for hypertension; and (3) basic model+blood pressure+treatment for hypertension+vascular risk factors and prevalent cardiovascular disease. For the basic model, left ventricular mass was inversely associated with abstract reasoning (similarities), visual-spatial memory and organization, and verbal memory. For the basic model+blood pressure+treatment for hypertension, left ventricular mass was inversely associated with similarities and visual-spatial memory and organization. For the basic+blood pressure+treatment for hypertension+risk factors+cardiovascular disease model, no significant associations were observed. Echocardiographic left ventricular mass is associated with cognitive performance beyond casual and time-averaged systolic blood pressure, but this association is attenuated and rendered nonsignificant with additional adjustment for cardiovascular risk factors and cardiovascular disease, thus suggesting that these variables play an important role in mediating the association between left ventricular mass and cognition.
Lee, Simon; Lytrivi, Irene D; Roytman, Zhanna; Ko, Hyun-Sook Helen; Vinograd, Cheryl; Srivastava, Shubhika
2016-10-01
Introduction Agreement between echocardiography and right heart catheterisation-derived right ventricular systolic pressure is modest in the adult heart failure population, but is unknown in the paediatric cardiomyopathy population. All patients at a single centre from 2001 to 2012 with a diagnosis of cardiomyopathy who underwent echocardiography and catheterisation within 30 days were included in this study. The correlation between tricuspid regurgitation gradient and catheterisation-derived right ventricular systolic pressure and mean pulmonary artery pressure was determined. Agreement between echocardiography and catheterisation-derived right ventricular systolic pressure was assessed using Bland-Altman plots. Analysis was repeated for patients who underwent both procedures within 7 days. Haemodynamic data from those with poor agreement and good agreement between echocardiography and catheterisation were compared. A total of 37 patients who underwent 48 catheterisation procedures were included in our study. The median age was 11.8 (0.1-20.6 years) with 22 males (58% total). There was a modest correlation (r=0.65) between echocardiography and catheterisation-derived right ventricular systolic pressure, but agreement was poor. Agreement between tricuspid regurgitation gradient and right ventricular systolic pressure showed wide 95% limits of agreement. There was a modest correlation between the tricuspid regurgitation gradient and mean pulmonary artery pressure (r=0.6). Shorter time interval between the two studies did not improve agreement. Those with poor agreement between echocardiography and catheterisation had higher right heart pressures, but this difference became insignificant after accounting for right atrial pressure. Transthoracic echocardiography estimation of right ventricular systolic pressure shows modest correlation with right heart pressures, but has limited agreement and may underestimate the degree of pulmonary hypertension in paediatric cardiomyopathy patients.
Gültekin, Bahadır; Ersoy, Özgür; Akkaya, İlknur; Kayıpmaz, Çağrı; Pirat, Araş; Sezgin, Atilla
2016-11-01
Left ventricular distention can be recognized during the use of venoarterial extracorporeal membrane oxygenation as a key complication. Left ventricular decompression may decrease pulmonary pressure, minimize ventricular distention, and allow myocardial recovery. We applied venoarterial extracorporeal membrane oxygenation to 4 patients while on a wait list for cardiac transplant. Two patients with severe heart failure developed high end-diastolic pressures leading to left ventricular distention. We used atrial venting methods to decrease the pressure. Here, we discussed the strategies to manage ventricular distention by conservative, interventional, and surgical means.
Effects of increasing left ventricular filling pressure in patients with acute myocardial infarction
Russell, Richard O.; Rackley, Charles E.; Pombo, Jaoquin; Hunt, David; Potanin, Constantine; Dodge, Harold T.
1970-01-01
Left ventricular performance in 19 patients with acute myocardial infarction has been evaluated by measuring left ventricular response in terms of cardiac output, stroke volume, work, and power to progressive elevation of filling pressure accomplished by progressive expansion of blood volume with rapid infusion of low molecular weight dextran. Such infusion can elevate the cardiac output, stroke volume, work, and power and thus delineate the function of the left ventricle by Frank-Starling function curves. Left ventricular filling pressure in the range of 20-24 mm Hg was associated with the peak of the curves and when the filling pressure exceeded this range, the curves became flattened or decreased. An increase in cardiac output could be maintained for 4 or more hr. Patients with a flattened function curve had a high mortality in the ensuing 8 wk. The function curve showed improvement in myocardial function during the early convalescence. When left ventricular filling pressure is monitored directly or as pulmonary artery end-diastolic pressure, low molecular weight dextran provides a method for assessment of left ventricular function. Images PMID:5431663
A porcine model for acute ischaemic right ventricular dysfunction.
Haraldsen, Pernille; Lindstedt, Sandra; Metzsch, Carsten; Algotsson, Lars; Ingemansson, Richard
2014-01-01
To establish an experimental model for acute ischaemic isolated right ventricular dysfunction and the subsequent haemodynamic changes. An open-chest porcine model with ischaemic dysfunction of the right ventricle induced by ligation of the three main branches supporting the right ventricular free wall. Invasive monitoring of mean arterial blood pressure (MAP), central venous pressure (CVP), left atrial pressure (LAP) and right ventricular pressure (RVP); ultrasonic measurement of cardiac output (CO) and calculation of haemodynamic parameters such as stroke volume (SV), systemic vascular resistance (SVR), pulmonary vascular resistance (PVR) and right ventricular stroke work (RVSW) using standard formulae. The ischaemic challenge to the right ventricle resulted in a significant (≥30%) reduction in RVSW associated with an increase (6-25%) in CVP and reduction (8-18%) in pulmonary artery pressure (PAP) despite unchanged PVR, all reflecting the failing right ventricle. There was also a significant drop in CO (14-22%) despite unchanged LAP indicating lessened transpulmonary delivery of left ventricular preload due to the failing right ventricle causing the haemodynamic compromise rather than left ventricular failure. Supraventricular and ventricular arrhythmias occurred in three and two out of seven pigs, respectively-all of which except one were successfully resuscitated with cardioversion and/or defibrillation. This novel open-chest porcine model of induced ischaemia of the right ventricular free wall resulted in significant haemodynamic compromise confirmed using standard haemodynamic measurements making it useful for further research on acute, ischaemic isolated right ventricular failure.
Fatouraee, Nasser; Saberi, Hazhir
2017-01-01
Purpose The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Methods Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. Results A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. Conclusion The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes. PMID:27776401
Sluyter, J D; Hughes, A D; Thom, S A McG; Lowe, A; Camargo, C A; Hametner, B; Wassertheurer, S; Parker, K H; Scragg, R K R
2017-05-01
Little is known about how aortic waveform parameters vary with ethnicity and lifestyle factors. We investigated these issues in a large, population-based sample. We carried out a cross-sectional analysis of 4798 men and women, aged 50-84 years from Auckland, New Zealand. Participants were 3961 European, 321 Pacific, 266 Maori and 250 South Asian people. We assessed modifiable lifestyle factors via questionnaires, and measured body mass index (BMI) and brachial blood pressure (BP). Suprasystolic oscillometry was used to derive aortic pressure, from which several haemodynamic parameters were calculated. Heavy alcohol consumption and BMI were positively related to most waveform parameters. Current smokers had higher levels of aortic augmentation index than non-smokers (difference=3.7%, P<0.0001). Aortic waveform parameters, controlling for demographics, antihypertensives, diabetes and cardiovascular disease (CVD), were higher in non-Europeans than in Europeans. Further adjustment for brachial BP or lifestyle factors (particularly BMI) reduced many differences but several remained. Despite even further adjustment for mean arterial pressure, pulse rate, height and total:high-density lipoprotein cholesterol, compared with Europeans, South Asians had higher levels of all measured aortic waveform parameters (for example, for backward pressure amplitude: β=1.5 mm Hg; P<0.0001), whereas Pacific people had 9% higher log e (excess pressure integral) (P<0.0001). In conclusion, aortic waveform parameters varied with ethnicity in line with the greater prevalence of CVD among non-white populations. Generally, this was true even after accounting for brachial BP, suggesting that waveform parameters may have increased usefulness in capturing ethnic variations in cardiovascular risk. Heavy alcohol consumption, smoking and especially BMI may partially contribute to elevated levels of these parameters.
Sluyter, J D; Hughes, A D; Thom, S A McG; Lowe, A; Camargo Jr, C A; Hametner, B; Wassertheurer, S; Parker, K H; Scragg, R K R
2017-01-01
Little is known about how aortic waveform parameters vary with ethnicity and lifestyle factors. We investigated these issues in a large, population-based sample. We carried out a cross-sectional analysis of 4798 men and women, aged 50–84 years from Auckland, New Zealand. Participants were 3961 European, 321 Pacific, 266 Maori and 250 South Asian people. We assessed modifiable lifestyle factors via questionnaires, and measured body mass index (BMI) and brachial blood pressure (BP). Suprasystolic oscillometry was used to derive aortic pressure, from which several haemodynamic parameters were calculated. Heavy alcohol consumption and BMI were positively related to most waveform parameters. Current smokers had higher levels of aortic augmentation index than non-smokers (difference=3.7%, P<0.0001). Aortic waveform parameters, controlling for demographics, antihypertensives, diabetes and cardiovascular disease (CVD), were higher in non-Europeans than in Europeans. Further adjustment for brachial BP or lifestyle factors (particularly BMI) reduced many differences but several remained. Despite even further adjustment for mean arterial pressure, pulse rate, height and total:high-density lipoprotein cholesterol, compared with Europeans, South Asians had higher levels of all measured aortic waveform parameters (for example, for backward pressure amplitude: β=1.5 mm Hg; P<0.0001), whereas Pacific people had 9% higher loge (excess pressure integral) (P<0.0001). In conclusion, aortic waveform parameters varied with ethnicity in line with the greater prevalence of CVD among non-white populations. Generally, this was true even after accounting for brachial BP, suggesting that waveform parameters may have increased usefulness in capturing ethnic variations in cardiovascular risk. Heavy alcohol consumption, smoking and especially BMI may partially contribute to elevated levels of these parameters. PMID:28004730
Weak shock propagation through a turbulent atmosphere
NASA Technical Reports Server (NTRS)
Pierce, Allan D.; Sparrow, Victor W.
1990-01-01
Consideration is given to the propagation through turbulence of transient pressure waveforms whose initial onset at any given point is an abrupt shock. The work is motivated by the desire to eventually develop a mathematical model for predicting statistical features, such as peak overpressures and spike widths, of sonic booms generated by supersonic aircraft. It is argued that the transient waveform received at points where x greater than 0 will begin with a pressure jump and a formulation is developed for predicting the amount of this jump and the time derivatives of the pressure waveform immediately following the jump.
Indik, Julia H; Conover, Zacherie; McGovern, Meghan; Silver, Annemarie E; Spaite, Daniel W; Bobrow, Bentley J; Kern, Karl B
2014-09-30
Previous investigations of out-of-hospital cardiac arrest (OHCA) have shown that the waveform characteristic amplitude spectral area (AMSA) can predict successful defibrillation and return of spontaneous circulation (ROSC) but has not been studied previously for survival. To determine whether AMSA computed from the ventricular fibrillation (VF) waveform is associated with pre-hospital ROSC, hospital admission, and hospital discharge. Adults with witnessed OHCA and an initial rhythm of VF from an Utstein style database were studied. AMSA was measured prior to each shock and averaged for each subject (AMSA-avg). Factors such as age, sex, number of shocks, time from dispatch to monitor/defibrillator application, first shock AMSA, and AMSA-avg that could predict pre-hospital ROSC, hospital admission, and hospital discharge were analyzed by logistic regression. Eighty-nine subjects (mean age 62 ± 15 years) with a total of 286 shocks were analyzed. AMSA-avg was associated with pre-hospital ROSC (p = 0.003); a threshold of 20.9 mV-Hz had a 95% sensitivity and a 43.4% specificity. Additionally, AMSA-avg was associated with hospital admission (p < 0.001); a threshold of 21 mV-Hz had a 95% sensitivity and a 54% specificity and with hospital discharge (p < 0.001); a threshold of 25.6 mV-Hz had a 95% sensitivity and a 53% specificity. First-shock AMSA was also predictive of pre-hospital ROSC, hospital admission, and discharge. Time from dispatch to monitor/defibrillator application was associated with hospital admission (p = 0.034) but not pre-hospital ROSC or hospital discharge. AMSA is highly associated with pre-hospital ROSC, survival to hospital admission, and hospital discharge in witnessed VF OHCA. Future studies are needed to determine whether AMSA computed during resuscitation can identify patients for whom continuing current resuscitation efforts would likely be futile. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Importance of the mitral apparatus for left ventricular function: an experimental approach.
Gams, E; Hagl, S; Schad, H; Heimisch, W; Mendler, N; Sebening, F
1992-01-01
In an experimental study of 31 anesthetized dogs the importance of the mitral apparatus for the left ventricular function was investigated. During extracorporeal circulation bileaflet mitral valve prostheses were implanted preserving the mitral subvalvular apparatus. Flexible wires were slung around the chordae tendineae and exteriorized through the left ventricular wall to cut the chordae by electrocautery from the outside when the heart was beating again. External and internal left ventricular dimensions were measured by sonomicrometry, left ventricular stroke volume by electromagnetic flowmeters around the ascending aorta, left ventricular end-diastolic volume by dye dilution technique, and left ventricular pressure by catheter tip manometers. Different preload levels were achieved by volume loading with blood transfusion before and after cutting the chordae tendineae. When the chordae had been divided peak systolic left ventricular pressure did not change. Heart rate only increased at the lowest left ventricular end-diastolic pressures of 3-4 mmHg, but remained unchanged at higher preload levels. Cardiac output decreased significantly up to -9% at left ventricular end-diastolic pressures of 5-10 mmHg, while left ventricular dp/dtmax showed a consistent reduction of up to -15% at any preload level. Significant reductions were also seen in systolic shortening in the left ventricular major axis (by external measurements -27%, by internal recording -43%). Left ventricular end-diastolic dimensions increased in the major axis by +2% when recorded externally, by +10% when measured internally. Systolic and diastolic changes in the minor axis were not consistent and different in the external and internal recordings.(ABSTRACT TRUNCATED AT 250 WORDS)
Seo, Joohyun; Pietrangelo, Sabino J; Sodini, Charles G; Lee, Hae-Seung
2018-05-01
This paper details unfocused imaging using single-element ultrasound transducers for motion tolerant arterial blood pressure (ABP) waveform estimation. The ABP waveform is estimated based on pulse wave velocity and arterial pulsation through Doppler and M-mode ultrasound. This paper discusses approaches to mitigate the effect of increased clutter due to unfocused imaging on blood flow and diameter waveform estimation. An intensity reduction model (IRM) estimator is described to track the change of diameter, which outperforms a complex cross-correlation model (C3M) estimator in low contrast environments. An adaptive clutter filtering approach is also presented, which reduces the increased Doppler angle estimation error due to unfocused imaging. Experimental results in a flow phantom demonstrate that flow velocity and diameter waveforms can be reliably measured with wide lateral offsets of the transducer position. The distension waveform estimated from human carotid M-mode imaging using the IRM estimator shows physiological baseline fluctuations and 0.6-mm pulsatile diameter change on average, which is within the expected physiological range. These results show the feasibility of this low cost and portable ABP waveform estimation device.
ECG signal analysis through hidden Markov models.
Andreão, Rodrigo V; Dorizzi, Bernadette; Boudy, Jérôme
2006-08-01
This paper presents an original hidden Markov model (HMM) approach for online beat segmentation and classification of electrocardiograms. The HMM framework has been visited because of its ability of beat detection, segmentation and classification, highly suitable to the electrocardiogram (ECG) problem. Our approach addresses a large panel of topics some of them never studied before in other HMM related works: waveforms modeling, multichannel beat segmentation and classification, and unsupervised adaptation to the patient's ECG. The performance was evaluated on the two-channel QT database in terms of waveform segmentation precision, beat detection and classification. Our waveform segmentation results compare favorably to other systems in the literature. We also obtained high beat detection performance with sensitivity of 99.79% and a positive predictivity of 99.96%, using a test set of 59 recordings. Moreover, premature ventricular contraction beats were detected using an original classification strategy. The results obtained validate our approach for real world application.
Real-time display of flow-pressure-volume loops.
Morozoff, P E; Evans, R W
1992-01-01
Graphic display of respiratory waveforms can be valuable for monitoring the progress of ventilated patients. A system has been developed that can display flow-pressure-volume loops as derived from a patient's respiratory circuit in real time. It can also display, store, print, and retrieve ventilatory waveforms. Five loops can be displayed at once: current, previous, reference, "ideal," and previously saved. Two components, the data-display device (DDD) and the data-collection device (DCD), comprise the system. An IBM 286/386 computer with a graphics card (VGA) and bidirectional parallel port is used for the DDD; an eight-bit microprocessor card and an A/D convertor card make up the DCD. A real-time multitasking operating system was written to control the DDD, while the DCD operates from in-line assembly code. The DCD samples the pressure and flow sensors at 100 Hz and looks for a complete flow waveform pattern based on flow slope. These waveforms are then passed to the DDD via the mutual parallel port. Within the DDD a process integrates the flow to create a volume signal and performs a multilinear regression on the pressure, flow, and volume data to calculate the elastance, resistance, pressure offset, and coefficient of determination. Elastance, resistance, and offset are used to calculate Pr and Pc where: Pr[k] = P[k]-offset-(elastance.V[k]) and Pc[k] = P[k]-offset-(resistance.F[k]). Volume vs. Pc and flow vs. Pr can be displayed in real time. Patient data from previous clinical tests were loaded into the device to verify the software calculations. An analog waveform generator was used to simulate flow and pressure waveforms that validated the system.(ABSTRACT TRUNCATED AT 250 WORDS)
Computational assessment of model-based wave separation using a database of virtual subjects.
Hametner, Bernhard; Schneider, Magdalena; Parragh, Stephanie; Wassertheurer, Siegfried
2017-11-07
The quantification of arterial wave reflection is an important area of interest in arterial pulse wave analysis. It can be achieved by wave separation analysis (WSA) if both the aortic pressure waveform and the aortic flow waveform are known. For better applicability, several mathematical models have been established to estimate aortic flow solely based on pressure waveforms. The aim of this study is to investigate and verify the model-based wave separation of the ARCSolver method on virtual pulse wave measurements. The study is based on an open access virtual database generated via simulations. Seven cardiac and arterial parameters were varied within physiological healthy ranges, leading to a total of 3325 virtual healthy subjects. For assessing the model-based ARCSolver method computationally, this method was used to perform WSA based on the aortic root pressure waveforms of the virtual patients. Asa reference, the values of WSA using both the pressure and flow waveforms provided by the virtual database were taken. The investigated parameters showed a good overall agreement between the model-based method and the reference. Mean differences and standard deviations were -0.05±0.02AU for characteristic impedance, -3.93±1.79mmHg for forward pressure amplitude, 1.37±1.56mmHg for backward pressure amplitude and 12.42±4.88% for reflection magnitude. The results indicate that the mathematical blood flow model of the ARCSolver method is a feasible surrogate for a measured flow waveform and provides a reasonable way to assess arterial wave reflection non-invasively in healthy subjects. Copyright © 2017 Elsevier Ltd. All rights reserved.
Unsteady blade pressures on a propfan at takeoff: Euler analysis and flight data
NASA Technical Reports Server (NTRS)
Nallasamy, M.
1991-01-01
The unsteady blade pressures due to the operation of the propfan at an angle to the direction of the mean flow are obtained by solving the unsteady three dimensional Euler equations. The configuration considered is the eight bladed SR7L propfan at takeoff conditions and the inflow angles considered are 6.3 deg, 8.3 deg, 11.3 deg. The predicted blade pressure waveforms are compared with inflight measurements. At the inboard radial station (r/R = 0.68) the phase of the predicted waveforms show reasonable agreement with the measurements while the amplitudes are over predicted in the leading edge region of the blade. At the outboard radial station (r/R = 0.95), the predicted amplitudes of the waveforms on the pressure surface are in good agreement with flight data for all inflow angles. The measured (installed propfan) waveforms show a relative phase lag compared to the computed (propfan alone) waveforms. The phase lag depends on the axial location of the transducer and the surface of the blade. On the suction surface, in addition to the relative phase lag, the measurements show distortion (widening and steepening) of the waveforms. The extent of distortion increases with increase in inflow angle. This distortion seems to be due to viscous separation effects which depend on the azimuthal location of the blade and the axial location of the transducer.
Model-Based, Noninvasive Monitoring of Intracranial Pressure
2013-07-01
patients. A physiologically based model relates ICP to simultaneously measured waveforms of arterial blood pressure ( ABP ), obtained via radial... ABP and CBFV are currently measured as the clinical standard of care. The project’s major accomplishments include: assembling a suitable system for...synchronized arterial blood pressure ( ABP ) and cerebral blood flow velocity (CBFV) waveform measurements that can be obtained quite routinely. Our processing
Partial discharge detection and analysis in low pressure environments
NASA Astrophysics Data System (ADS)
Liu, Xin
Typical aerospace vehicles (aircraft and spacecraft) experience a wide range of operating pressures during ascending and returning to earth. Compared to the sea-level atmospheric pressure (760 Torr), the pressure at about 60 km altitude is 2 Torr. The performance of the electric power system components of the aerospace vehicles must remain reliable even under such sub-atmospheric operating conditions. It is well known that the dielectric strength of gaseous insulators, while the electrode arrangement remains unchanged, is pressure dependent. Therefore, characterization of the performance and behavior of the electrical insulation in flight vehicles in low-pressure environments is extremely important. Partial discharge testing is one of the practical methods for evaluating the integrity of electrical insulation in aerospace vehicles. This dissertation describes partial discharge (PD) measurements performed mainly with 60 Hz ac energization in air, argon and helium, for pressures between 2 and 760 Torr. Two main electrode arrangements were used. One was a needle-plane electrode arrangement with a Teflon insulating barrier. The other one was a twisted pair of insulated conductors taken from a standard aircraft wiring harness. The measurement results are presented in terms of typical PD current pulse waveforms and waveform analysis for both main electrode arrangements. The evaluation criteria are the waveform polarity, magnitude, shape, rise time, and phase angle (temporal location) relative to the source voltage. Two-variable histograms and statistical averages of the PD parameters are presented. The PD physical mechanisms are analyzed. For PD pattern recognition, both statistical methods (such as discharge parameter dot pattern representation, discharge parameter phase distribution, statistical operator calculations, and PD fingerprint development) and wavelet transform applications are investigated. The main conclusions of the dissertation include: (1) The PD current pulse waveforms are dependent on the pressure. (2) The rise time of the waveform is another effective PD current pulse characteristic indicator. (3) PD fingerprint patterns that are already available for atmospheric pressure (760 Torr) conditions are inadequate for the evaluation of PD pulses at low pressures. (4) Various wavelet transform techniques can be used effectively for PD pulse signal denoising purposes, and for PD pulse waveform transient feature recognition.
Graphical Man/Machine Communications
Progress is reported concerning the use of computer controlled graphical displays in the areas of radiaton diffusion and hydrodynamics, general...ventricular dynamics. Progress is continuing on the use of computer graphics in architecture. Some progress in halftone graphics is reported with no basic...developments presented. Colored halftone perspective pictures are being used to represent multivariable situations. Nonlinear waveform processing is
Computation of acoustic ressure fields produced in feline brain by high-intensity focused ultrasound
NASA Astrophysics Data System (ADS)
Omidi, Nazanin
In 1975, Dunn et al. (JASA 58:512-514) showed that a simple relation describes the ultrasonic threshold for cavitation-induced changes in the mammalian brain. The thresholds for tissue damage were estimated for a variety of acoustic parameters in exposed feline brain. The goal of this study was to improve the estimates for acoustic pressures and intensities present in vivo during those experimental exposures by estimating them using nonlinear rather than linear theory. In our current project, the acoustic pressure waveforms produced in the brains of anesthetized felines were numerically simulated for a spherically focused, nominally f1-transducer (focal length = 13 cm) at increasing values of the source pressure at frequencies of 1, 3, and 9 MHz. The corresponding focal intensities were correlated with the experimental data of Dunn et al. The focal pressure waveforms were also computed at the location of the true maximum. For low source pressures, the computed waveforms were the same as those determined using linear theory, and the focal intensities matched experimentally determined values. For higher source pressures, the focal pressure waveforms became increasingly distorted, with the compressional amplitude of the wave becoming greater, and the rarefactional amplitude becoming lower than the values calculated using linear theory. The implications of these results for clinical exposures are discussed.
Sade, Leyla Elif; Kozan, Hatice; Eroglu, Serpil; Pirat, Bahar; Aydinalp, Alp; Sezgin, Atilla; Muderrisoglu, Haldun
2017-02-01
Residual pulmonary hypertension challenges the right ventricular function and worsens the prognosis in heart transplant recipients. The complex geometry of the right ventricle complicates estimation of its function with conventional transthoracic echocardiography. We evaluated right ventricular function in heart transplant recipients with the use of 3-dimensional echocardiography in relation to systolic pulmonary artery pressure. We performed 32 studies in 26 heart transplant patients, with 6 patients having 2 studies at different time points with different pressures and thus included. Right atrial volume, tricuspid annular plane systolic excursion, peak systolic annular velocity, fractional area change, and 2-dimensional speckle tracking longitudinal strain were obtained by 2-dimensional and tissue Doppler imaging. Three-dimensional right ventricular volumes, ejection fraction, and 3-dimensional right ventricular strain were obtained from the 3-dimensional data set by echocardiographers. Systolic pulmonary artery pressure was obtained during right heart catheterization. Overall mean systolic pulmonary artery pressure was 26 ± 7 mm Hg (range, 14-44 mmHg). Three-dimensional end-diastolic (r = 0.75; P < .001) and end-systolic volumes (r = 0.55; P = .001)correlated well with systolic pulmonary artery pressure. Right ventricular ejection fraction and right atrium volume also significantly correlated with systolic pulmonary artery pressure (r = 0.49 and P = .01 for both). However, right ventricular 2- and 3-dimensional strain, tricuspid annular plane systolic excursion, and tricuspid annular velocity did not. The effects of pulmonary hemodynamic burden on right ventricular function are better estimated by a 3-dimensional volume evaluation than with 3-dimensional longitudinal strain and other 2-dimensional and tissue Doppler measurements. These results suggest that the peculiar anatomy of the right ventricle necessitates 3-dimensional volume quantification in heart transplant recipients in relation to residual pulmonary hypertension.
The overloaded right heart and ventricular interdependence.
Naeije, Robert; Badagliacca, Roberto
2017-10-01
The right and the left ventricle are interdependent as both structures are nested within the pericardium, have the septum in common and are encircled with common myocardial fibres. Therefore, right ventricular volume or pressure overloading affects left ventricular function, and this in turn may affect the right ventricle. In normal subjects at rest, right ventricular function has negligible interaction with left ventricular function. However, the right ventricle contributes significantly to the normal cardiac output response to exercise. In patients with right ventricular volume overload without pulmonary hypertension, left ventricular diastolic compliance is decreased and ejection fraction depressed but without intrinsic alteration in contractility. In patients with right ventricular pressure overload, left ventricular compliance is decreased with initial preservation of left ventricular ejection fraction, but with eventual left ventricular atrophic remodelling and altered systolic function. Breathing affects ventricular interdependence, in healthy subjects during exercise and in patients with lung diseases and altered respiratory system mechanics. Inspiration increases right ventricular volumes and decreases left ventricular volumes. Expiration decreases both right and left ventricular volumes. The presence of an intact pericardium enhances ventricular diastolic interdependence but has negligible effect on ventricular systolic interdependence. On the other hand, systolic interdependence is enhanced by a stiff right ventricular free wall, and decreased by a stiff septum. Recent imaging studies have shown that both diastolic and systolic ventricular interactions are negatively affected by right ventricular regional inhomogeneity and prolongation of contraction, which occur along with an increase in pulmonary artery pressure. The clinical relevance of these observations is being explored. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Jones, Siana; Al-Lamee, Rasha; Foin, Nicolas; Al-Bustami, Mahmud; Sethi, Amarjit; Kaprielian, Raffi; Ramrakha, Punit; Khan, Masood; Malik, Iqbal S.; Francis, Darrel P.; Parker, Kim; Hughes, Alun D.; Mikhail, Ghada W.; Mayet, Jamil; Davies, Justin E.
2015-01-01
Wave intensity analysis (WIA) has found particular applicability in the coronary circulation where it can quantify traveling waves that accelerate and decelerate blood flow. The most important wave for the regulation of flow is the backward-traveling decompression wave (BDW). Coronary WIA has hitherto always been calculated from invasive measures of pressure and flow. However, recently it has become feasible to obtain estimates of these waveforms noninvasively. In this study we set out to assess the agreement between invasive and noninvasive coronary WIA at rest and measure the effect of exercise. Twenty-two patients (mean age 60) with unobstructed coronaries underwent invasive WIA in the left anterior descending artery (LAD). Immediately afterwards, noninvasive LAD flow and pressure were recorded and WIA calculated from pulsed-wave Doppler coronary flow velocity and central blood pressure waveforms measured using a cuff-based technique. Nine of these patients underwent noninvasive coronary WIA assessment during exercise. A pattern of six waves were observed in both modalities. The BDW was similar between invasive and noninvasive measures [peak: 14.9 ± 7.8 vs. −13.8 ± 7.1 × 104 W·m−2·s−2, concordance correlation coefficient (CCC): 0.73, P < 0.01; cumulative: −64.4 ± 32.8 vs. −59.4 ± 34.2 × 102 W·m−2·s−1, CCC: 0.66, P < 0.01], but smaller waves were underestimated noninvasively. Increased left ventricular mass correlated with a decreased noninvasive BDW fraction (r = −0.48, P = 0.02). Exercise increased the BDW: at maximum exercise peak BDW was −47.0 ± 29.5 × 104 W·m−2·s−2 (P < 0.01 vs. rest) and cumulative BDW −19.2 ± 12.6 × 103 W·m−2·s−1 (P < 0.01 vs. rest). The BDW can be measured noninvasively with acceptable reliably potentially simplifying assessments and increasing the applicability of coronary WIA. PMID:26683900
Broyd, Christopher J; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Jones, Siana; Al-Lamee, Rasha; Foin, Nicolas; Al-Bustami, Mahmud; Sethi, Amarjit; Kaprielian, Raffi; Ramrakha, Punit; Khan, Masood; Malik, Iqbal S; Francis, Darrel P; Parker, Kim; Hughes, Alun D; Mikhail, Ghada W; Mayet, Jamil; Davies, Justin E
2016-03-01
Wave intensity analysis (WIA) has found particular applicability in the coronary circulation where it can quantify traveling waves that accelerate and decelerate blood flow. The most important wave for the regulation of flow is the backward-traveling decompression wave (BDW). Coronary WIA has hitherto always been calculated from invasive measures of pressure and flow. However, recently it has become feasible to obtain estimates of these waveforms noninvasively. In this study we set out to assess the agreement between invasive and noninvasive coronary WIA at rest and measure the effect of exercise. Twenty-two patients (mean age 60) with unobstructed coronaries underwent invasive WIA in the left anterior descending artery (LAD). Immediately afterwards, noninvasive LAD flow and pressure were recorded and WIA calculated from pulsed-wave Doppler coronary flow velocity and central blood pressure waveforms measured using a cuff-based technique. Nine of these patients underwent noninvasive coronary WIA assessment during exercise. A pattern of six waves were observed in both modalities. The BDW was similar between invasive and noninvasive measures [peak: 14.9 ± 7.8 vs. -13.8 ± 7.1 × 10(4) W·m(-2)·s(-2), concordance correlation coefficient (CCC): 0.73, P < 0.01; cumulative: -64.4 ± 32.8 vs. -59.4 ± 34.2 × 10(2) W·m(-2)·s(-1), CCC: 0.66, P < 0.01], but smaller waves were underestimated noninvasively. Increased left ventricular mass correlated with a decreased noninvasive BDW fraction (r = -0.48, P = 0.02). Exercise increased the BDW: at maximum exercise peak BDW was -47.0 ± 29.5 × 10(4) W·m(-2)·s(-2) (P < 0.01 vs. rest) and cumulative BDW -19.2 ± 12.6 × 10(3) W·m(-2)·s(-1) (P < 0.01 vs. rest). The BDW can be measured noninvasively with acceptable reliably potentially simplifying assessments and increasing the applicability of coronary WIA. Copyright © 2016 the American Physiological Society.
Bonow, R O; Ostrow, H G; Rosing, D R; Cannon, R O; Lipson, L C; Maron, B J; Kent, K M; Bacharach, S L; Green, M V
1983-11-01
To investigate the effects of verapamil on left ventricular systolic and diastolic function in patients with hypertrophic cardiomyopathy, we studied 14 patients at catheterization with a nonimaging scintillation probe before and after serial intravenous infusions of low-, medium-, and high-dose verapamil (total dose 0.17 to 0.72 mg/kg). Percent change in radionuclide stroke counts after verapamil correlated well with percent change in thermodilution stroke volume (r = .87), and changes in diastolic and systolic counts were used to assess relative changes in left ventricular volumes after verapamil. Verapamil produced dose-related increases in end-diastolic counts (19 +/- 9% increase; p less than .001), end-systolic counts (91 +/- 54% increase; p less than .001), and stroke counts (7 +/- 10% increase; p less than .02). This was associated with a decrease in ejection fraction (83 +/- 8% control, 73 +/- 10% verapamil; p less than .001) and, in the 10 patients with left ventricular outflow tract gradients, a reduction in gradient (62 +/- 27 mm Hg control, 32 +/- 35 mm Hg verapamil; p less than .01). The end-systolic pressure-volume relation was shifted downward and rightward in all patients, suggesting a negative inotropic effect. In 10 patients, left ventricular pressure-volume loops were constructed with simultaneous micromanometer pressure recordings and the radionuclide time-activity curve. In five patients, verapamil shifted the diastolic pressure-volume curve downward and rightward, demonstrating improved pressure-volume relations despite the negative inotropic effect, and also increased the peak rate of rapid diastolic filling. In the other five patients, the diastolic pressure-volume relation was unaltered by verapamil, and increased end-diastolic volumes occurred at higher end-diastolic pressures; in these patients, the peak rate of left ventricular diastolic filling was not changed by verapamil. The negative inotropic effects of intravenous verapamil are potentially beneficial in patients with hypertrophic cardiomyopathy by decreasing left ventricular contractile function and increasing left ventricular volume. Verapamil also enhances left ventricular diastolic filling and improves diastolic pressure-volume relations in some patients despite its negative inotropic effect.
Firstenberg, M S; Smedira, N G; Greenberg, N L; Prior, D L; McCarthy, P M; Garcia, M J; Thomas, J D
2001-09-18
Early diastolic intraventricular pressure gradients (IVPGs) have been proposed to relate to left ventricular (LV) elastic recoil and early ventricular "suction." Animal studies have demonstrated relationships between IVPGs and systolic and diastolic indices during acute ischemia. However, data on the effects of improvements in LV function in humans and the relationship to IVPGs are lacking. Eight patients undergoing CABG and/or infarct exclusion surgery had a triple-sensor high-fidelity catheter placed across the mitral valve intraoperatively for simultaneous recording of left atrial (LA), basal LV, and apical LV pressures. Hemodynamic data obtained before bypass were compared with those with similar LA pressures and heart rates obtained after bypass. From each LV waveform, the time constant of LV relaxation (tau), +dP/dt(max), and -dP/dt(max) were determined. Transesophageal echocardiography was used to determined end-diastolic (EDV) and end-systolic (ESV) volumes and ejection fractions (EF). At similar LA pressures and heart rates, IVPG increased after bypass (before bypass 1.64+/-0.79 mm Hg; after bypass 2.67+/-1.25 mm Hg; P<0.01). Significant improvements were observed in ESV, as well as in apical and basal +dP/dt(max), -dP/dt(max), and tau (each P<0.05). Overall, IVPGs correlated inversely with both ESV (IVPG=-0.027[ESV]+3.46, r=-0.64) and EDV (IVPG=-0.027[EDV]+4.30, r=-0.70). Improvements in IVPGs correlated with improvements in apical tau (Deltatau =5.93[DeltaIVPG]+4.76, r=0.91) and basal tau (Deltatau =2.41[DeltaIVPG]+5.13, r=-0.67). Relative changes in IVPGs correlated with changes in ESV (DeltaESV=-0.97[%DeltaIVPG]+23.34, r=-0.79), EDV (DeltaEDV=-1.16[%DeltaIVPG]+34.92, r=-0.84), and EF (DeltaEF=0.38[%DeltaIVPG]-8.39, r=0.85). Improvements in LV function also increase IVPGs. These changes in IVPGs, suggestive of increases in LV suction and elastic recoil, correlate directly with improvements in LV relaxation and ESV.
NASA Technical Reports Server (NTRS)
Firstenberg, M. S.; Smedira, N. G.; Greenberg, N. L.; Prior, D. L.; McCarthy, P. M.; Garcia, M. J.; Thomas, J. D.
2001-01-01
BACKGROUND: Early diastolic intraventricular pressure gradients (IVPGs) have been proposed to relate to left ventricular (LV) elastic recoil and early ventricular "suction." Animal studies have demonstrated relationships between IVPGs and systolic and diastolic indices during acute ischemia. However, data on the effects of improvements in LV function in humans and the relationship to IVPGs are lacking. METHODS AND RESULTS: Eight patients undergoing CABG and/or infarct exclusion surgery had a triple-sensor high-fidelity catheter placed across the mitral valve intraoperatively for simultaneous recording of left atrial (LA), basal LV, and apical LV pressures. Hemodynamic data obtained before bypass were compared with those with similar LA pressures and heart rates obtained after bypass. From each LV waveform, the time constant of LV relaxation (tau), +dP/dt(max), and -dP/dt(max) were determined. Transesophageal echocardiography was used to determined end-diastolic (EDV) and end-systolic (ESV) volumes and ejection fractions (EF). At similar LA pressures and heart rates, IVPG increased after bypass (before bypass 1.64+/-0.79 mm Hg; after bypass 2.67+/-1.25 mm Hg; P<0.01). Significant improvements were observed in ESV, as well as in apical and basal +dP/dt(max), -dP/dt(max), and tau (each P<0.05). Overall, IVPGs correlated inversely with both ESV (IVPG=-0.027[ESV]+3.46, r=-0.64) and EDV (IVPG=-0.027[EDV]+4.30, r=-0.70). Improvements in IVPGs correlated with improvements in apical tau (Deltatau =5.93[DeltaIVPG]+4.76, r=0.91) and basal tau (Deltatau =2.41[DeltaIVPG]+5.13, r=-0.67). Relative changes in IVPGs correlated with changes in ESV (DeltaESV=-0.97[%DeltaIVPG]+23.34, r=-0.79), EDV (DeltaEDV=-1.16[%DeltaIVPG]+34.92, r=-0.84), and EF (DeltaEF=0.38[%DeltaIVPG]-8.39, r=0.85). CONCLUSIONS: Improvements in LV function also increase IVPGs. These changes in IVPGs, suggestive of increases in LV suction and elastic recoil, correlate directly with improvements in LV relaxation and ESV.
Patterns of left ventricular remodeling among patients with essential and secondary hypertension.
Radulescu, Dan; Stoicescu, Laurentiu; Buzdugan, Elena; Donca, Valer
2013-12-01
High blood pressure causes left ventricular hypertrophy, which is a negative prognostic factor among hypertensive patients. To assess left ventricular geometric remodeling patterns in patients with essential hypertension or with hypertension secondary to parenchymal renal disease. We analyzed data from echocardiograms performed in 250 patients with essential hypertension (150 females) and 100 patients with secondary hypertension (60 females). The interventricular septum and the left ventricular posterior wall thickness were measured in the parasternal long-axis. Left ventricular mass was calculated using the Devereaux formula. The most common remodeling type in females and males with essential hypertension were eccentric and concentric left ventricular hypertrophy (cLVH), respectively. Among patients with secondary arterial hypertension, cLVH was most commonly observed in both genders. The prevalence of left ventricular hypertrophy was higher among patients with secondary hypertension. The left ventricular mass index and the relative left ventricular wall thickness were higher in males and also in the secondary hypertension group. Age, blood pressure values and the duration of hypertension, influenced remodeling patterns. We documented a higher prevalence of LVH among patients with secondary hypertension. The type of ventricular remodeling depends on gender, age, type of hypertension, blood pressure values and the duration of hypertension.
Childs, Charmaine; Shen, Liang
2015-06-23
Intraparenchymal, multimodality sensors are commonly used in the management of patients with severe traumatic brain injury (TBI). The 'gold standard', based on accuracy, reliability and cost for intracranial pressure (ICP) monitoring is within the cerebral ventricle (external strain gauge). There are no standards yet for intracerebral temperature monitoring and little is known of temperature differences between brain tissue and ventricle. The aim of the study therefore was to determine pressure and temperature differences at intraparenchymal and ventricular sites during five days of continuous neuromonitoring. Patients with severe TBI requiring emergency surgery. patients who required ICP monitoring were eligible for recruitment. Two intracerebral probe types were used: a) intraventricular, dual parameter sensor (measuring pressure, temperature) with inbuilt catheter for CSF drainage: b) multiparameter intraparenchymal sensor measuring pressure, temperature and oxygen partial pressure. All sensors were inserted during surgery and under aseptic conditions. Seventeen patients, 12 undergoing neurosurgery (decompressive craniectomy n = 8, craniotomy n = 4) aged 21-78 years were studied. Agreement of measures for 9540 brain tissue-ventricular temperature 'pairs' and 10,291 brain tissue-ventricular pressure 'pairs' were determined using mixed model to compare mean temperature and pressure for longitudinal data. There was no significant overall difference for mean temperature (p = 0.92) or mean pressure readings (p = 0.379) between tissue and ventricular sites. With 95.8 % of paired temperature readings within 2SD (-0.4 to 0.4 °C) differences in temperature between brain tissue and ventricle were clinically insignificant. For pressure, 93.5 % of readings pairs fell within the 2SD range (-9.4756 to 7.8112 mmHg). However, for individual patients, agreement for mean tissue-ventricular pressure differences was poor on occasions. There is good overall agreement between paired temperature measurements obtained from deep white matter and brain ventricle in patients with and without early neurosurgery. For paired ICP measurements, 93.5 % of readings were within 2SD of mean difference. Whilst the majority of paired readings were comparable (within 10 mmHg) clinically relevant tissue-ventricular dissociations were noted. Further work is required to unravel the events responsible for short intervals of pressure dissociation before tissue pressure readings can be definitively accepted as a reliable surrogate for ventricular pressure.
Higher sympathetic nerve activity during ventricular (VVI) than during dual-chamber (DDD) pacing
NASA Technical Reports Server (NTRS)
Taylor, J. A.; Morillo, C. A.; Eckberg, D. L.; Ellenbogen, K. A.
1996-01-01
OBJECTIVES: We determined the short-term effects of single-chamber ventricular pacing and dual-chamber atrioventricular (AV) pacing on directly measured sympathetic nerve activity. BACKGROUND: Dual-chamber AV cardiac pacing results in greater cardiac output and lower systemic vascular resistance than does single-chamber ventricular pacing. However, it is unclear whether these hemodynamic advantages result in less sympathetic nervous system outflow. METHODS: In 13 patients with a dual-chamber pacemaker, we recorded the electrocardiogram, noninvasive arterial pressure (Finapres), respiration and muscle sympathetic nerve activity (microneurography) during 3 min of underlying basal heart rate and 3 min of ventricular and AV pacing at rates of 60 and 100 beats/min. RESULTS: Arterial pressure was lowest and muscle sympathetic nerve activity was highest at the underlying basal heart rate. Arterial pressure increased with cardiac pacing and was greater with AV than with ventricular pacing (change in mean blood pressure +/- SE: 10 +/- 3 vs. 2 +/- 2 mm Hg at 60 beats/min; 21 +/- 5 vs. 14 +/- 2 mm Hg at 100 beats/min; p < 0.05). Sympathetic nerve activity decreased with cardiac pacing and the decline was greater with AV than with ventricular pacing (60 beats/min -40 +/- 11% vs. -17 +/- 7%; 100 beats/min -60 +/- 9% vs. -48 +/- 10%; p < 0.05). Although most patients showed a strong inverse relation between arterial pressure and muscle sympathetic nerve activity, three patients with severe left ventricular dysfunction (ejection fraction < or = 30%) showed no relation between arterial pressure and sympathetic activity. CONCLUSIONS: Short-term AV pacing results in lower sympathetic nerve activity and higher arterial pressure than does ventricular pacing, indicating that cardiac pacing mode may influence sympathetic outflow simply through arterial baroreflex mechanisms. We speculate that the greater incidence of adverse outcomes in patients treated with single-chamber ventricular rather than dual-chamber pacing may be due in part to increased sympathetic nervous outflow.
Ventricular distension and diastolic coronary blood flow in the anaesthetized dog.
Gattullo, D; Linden, R J; Losano, G; Pagliaro, P; Westerhof, N
1993-01-01
There appears to be no agreement as to whether or not an increase in diastolic left ventricular pressure and/or volume can cause a decrease in diastolic coronary blood flow. We investigated the problem in the anaesthetized dog using a flaccid freely distensible latex balloon inserted into the left ventricle with the animal on extracorporeal circulation and the coronary perfusion pressure constant at about 45 mm Hg. Maximal vasodilatation and suppression of autoregulation in coronary vasculature was obtained by the intracoronary infusion of dipyridamole (10-40 mg/h). Ventricular volume was changed in steps of 10 ml from 10 to 70 ml and back to 10 ml, whilst recording coronary blood flow and left ventricular pressure in the left circumflex coronary artery. Over a range of ventricular volumes from 20 to 50 ml and a concomitant rise in diastolic ventricular pressure to about 20 mm Hg there was no change in the diastolic coronary flow. Only when the ventricular volume was more than two times the control value (i.e. exceeded 50 ml) and left ventricular pressure was more than 20 mm Hg, was there a decrease in coronary flow. During the return of the volume to the control level there was a fall in diastolic flow and ventricular contractility with respect to the values obtained when the volume was increased; these two effects were transient lasting less than 10 min. It was not considered that any of the three models of the coronary circulation, waterfall, intramyocardial pump or varying elastance model could explain our results.(ABSTRACT TRUNCATED AT 250 WORDS)
Alian, Aymen A; Atteya, Gourg; Gaal, Dorothy; Golembeski, Thomas; Smith, Brian G; Dai, Feng; Silverman, David G; Shelley, Kirk
2016-08-01
Scoliosis surgery is often associated with substantial blood loss, requiring fluid resuscitation and blood transfusions. In adults, dynamic preload indices have been shown to be more reliable for guiding fluid resuscitation, but these indices have not been useful in children undergoing surgery. The aim of this study was to introduce frequency-analyzed photoplethysmogram (PPG) and arterial pressure waveform variables and to study the ability of these parameters to detect early bleeding in children during surgery. We studied 20 children undergoing spinal fusion. Electrocardiogram, arterial pressure, finger pulse oximetry (finger PPG), and airway pressure waveforms were analyzed using time domain and frequency domain methods of analysis. Frequency domain analysis consisted of calculating the amplitude density of PPG and arterial pressure waveforms at the respiratory and cardiac frequencies using Fourier analysis. This generated 2 measurements: The first is related to slow mean arterial pressure modulation induced by ventilation (also known as DC modulation when referring to the PPG), and the second corresponds to pulse pressure modulation (AC modulation or changes in the amplitude of pulse oximeter plethysmograph when referring to the PPG). Both PPG and arterial pressure measurements were divided by their respective cardiac pulse amplitude to generate DC% and AC% (normalized values). Standard hemodynamic data were also recorded. Data at baseline and after bleeding (estimated blood loss about 9% of blood volume) were presented as median and interquartile range and compared using Wilcoxon signed-rank tests; a Bonferroni-corrected P value <0.05 was considered statistically significant. There were significant increases in PPG DC% (median [interquartile range] = 359% [210 to 541], P = 0.002), PPG AC% (160% [87 to 251], P = 0.003), and arterial DC% (44% [19 to 84], P = 0.012) modulations, respectively, whereas arterial AC% modulations showed nonsignificant increase (41% [1 to 85], P = 0.12). The change in PPG DC% was significantly higher than that in PPG AC%, arterial DC%, arterial AC%, and systolic blood pressure with P values of 0.008, 0.002, 0.003, and 0.002, respectively. Only systolic blood pressure showed significant changes (11% [4 to 21], P = 0.003) between bleeding phase and baseline. Finger PPG and arterial waveform parameters (using frequency analysis) can track changes in blood volume during the bleeding phase, suggesting the potential for a noninvasive monitor for tracking changes in blood volume in pediatric patients. PPG waveform baseline modulation (PPG DC%) was more sensitive to changes in venous blood volume when compared with respiration-induced modulation seen in the arterial pressure waveform.
Mechanism of reduction of mitral regurgitation with vasodilator therapy.
Yoran, C; Yellin, E L; Becker, R M; Gabbay, S; Frater, R W; Sonnenblick, E H
1979-04-01
Acute mitral regurgitation was produced in six open chest dogs by excising a portion of the anterior valve leaflet. Electromagnetic flow probes were placed in the left atrium around the mitral anulus and in the ascending aorta to determine phasic left ventricular filling volume, regurgitant volume and stroke volume. The systolic pressure gradient was calculated from simultaneously measured high fidelity left atrial and left ventricular pressures. The effective mitral regurgitant orifice area was calculated from Gorlin's hydraulic equation. Infusion of nitroprusside resulted in a significant reduction in mitral regurgitation. No significant change occurred in the systolic pressure gradient between the left ventricle and the left atrium because both peak left ventricular pressure and left atrial pressure were reduced. The reduction of mitral regurgitation was largely due to reduction in the size of the mitral regurgitant orifice. Reduction of ventricular volume rather than the traditional concept of reduction of impedance of left ventricular ejection may explain the effects of vasodilators in reducing mitral regurgitation.
Thickness noise of a propeller and its relation to blade sweep
NASA Astrophysics Data System (ADS)
Amiet, R. K.
1988-07-01
Linear acoustic theory is used to determine the thickness noise produced by a supersonic propeller with sharp leading and trailing edges. The method reveals details of the calculated waveform. Abrupt changes of slope in the pressure-time waveform which are produced by singular points entering or leaving the tip blade are pointed out. It is found that the behavior of the pressure-time waveform is closely related to changes in the retarded rotor shape. The results indicate that logarithmic singularities in the waveform are produced by regions on the blade edges that move towards the observer at sonic speed, with the edge normal to the line joining the source point and the observer.
Thomas, J D; Flachskampf, F A; Chen, C; Guererro, J L; Picard, M H; Levine, R A; Weyman, A E
1992-11-01
The isovolumic relaxation time (IVRT) is an important noninvasive index of left ventricular diastolic function. Despite its widespread use, however, the IVRT has not been related analytically to invasive parameters of ventricular function. Establishing such a relationship would make the IVRT more useful by itself and perhaps allow it to be combined more precisely with other noninvasive parameters of ventricular filling. The purpose of this study was to validate such a quantitative relationship. Assuming isovolumic relaxation to be a monoexponential decay of ventricular pressure (pv) to a zero-pressure asymptote, it was postulated that the time interval from aortic valve closure (when pv = p(o)) until mitral valve opening (when pv = left atrial pressure, pA) would be given analytically by IVRT = tau[log(p(o))-log(pA)], where tau is the time constant of isovolumic relaxation and log is to the base e. To test this hypothesis we analyzed data from six canine experiments in which ventricular preload and afterload were controlled nonpharmacologically. In addition, tau was adjusted with the use of beta-adrenergic blockade and calcium infusion, as well as with hypothermia. In each experiment data were collected before and after the surgical formation of mitral stenosis, performed to permit the study of a wide range of left atrial pressures. High-fidelity left atrial, left ventricular, and aortic root pressures were digitized, the IVRT was measured from the aortic dicrotic notch until the left atrioventricular pressure crossover point, and tau was calculated by nonlinear least-squares regression.(ABSTRACT TRUNCATED AT 250 WORDS)
Airfoil gust response and the sound produced by airifoil-vortex interaction
NASA Technical Reports Server (NTRS)
Amiet, R. K.
1986-01-01
This paper contributes to the understanding of the noise generation process of an airfoil encountering an unsteady upwash. By using a fast Fourier transform together with accurate airfoil response functions, the lift-time waveform for an airfoil encountering a delta function gust (the indicial function) is calculated for a flat plate airfoil in a compressible flow. This shows the interesting property that the lift is constant until the generated acoustic wave reaches the trailing edge. Expressions are given for the magnitude of this constant and for the pressure distribution on the airfoil during this time interval. The case of an airfoil cutting through a line vortex is also analyzed. The pressure-time waveform in the far field is closely related to the left-time waveform for the above problem of an airfoil entering a delta function gust. The effects of varying the relevant parameters in the problem are studied, including the observed position, the core diameter of the vortex, the vortex orientation and the airfoil span. The far field sound varies significantly with observer position, illustrating the importance of non-compactness effects. Increasing the viscous core diameter tends to smooth the pressure-time waveform. For small viscous core radius and infinite span, changing the vortex orientation changes only the amplitude of the pressure-time waveform, and not the shape.
Left ventricular function during lower body negative pressure
NASA Technical Reports Server (NTRS)
Ahmad, M.; Blomqvist, C. G.; Mullins, C. B.; Willerson, J. T.
1977-01-01
The response of the human left ventricle to lower body negative pressure (LBNP) and the relation between left ventricular function and hemodynamic response were investigated. Ventricular function curves relating stroke volume to end-diastolic volume were obtained in 12 normal men. Volume data were derived from echocardiographic measurements of left ventricular end-systolic and end-diastolic diameters at rest and during lower body negative pressure (LBNP) at minus 40 mm Hg. End-diastolic volume decreased by 19% and stroke volume by 22%. There were no significant changes in heart rate, arterial blood pressure, or end-systolic volume. Thus, moderate levels of LBNP significantly reduce preload and stroke volume without affecting contractile state. The absence of significant changes in heart rate and arterial blood pressure in the presence of a significant reduction in stroke volume is consistent with an increase in systemic peripheral resistance mediated by low-pressure baroreceptors.
Extrapolation of sonic boom pressure signatures by the waveform parameter method
NASA Technical Reports Server (NTRS)
Thomas, C. L.
1972-01-01
The waveform parameter method of sonic boom extrapolation is derived and shown to be equivalent to the F-function method. A computer program based on the waveform parameter method is presented and discussed, with a sample case demonstrating program input and output.
Lennox, Pamela H; Umedaly, Hamed S; Grant, Raymer P; White, S Adrian; Fitzmaurice, Brett G; Evans, Kenneth G
2006-10-01
The purpose of this study was to assess the validity of using a pulsatile, pressure waveform transduced from the epidural space through an epidural needle or catheter to confirm correct placement for maximal analgesia and to compare 3 different types of catheters' ability to transduce a waveform. A single-center, prospective, randomized trial. A tertiary-referral hospital. Eighty-one patients undergoing posterolateral thoracotomy who required a thoracic epidural catheter for postoperative pain management. Each epidural needle and each epidural catheter was transduced to determine if there was a pulsatile waveform exhibited. Sensitivity of the pulsatile waveform transduced through an epidural needle to identify correct placement of the epidural needle and the sensitivity of each catheter type to identify placement were compared. In 79 of 81 cases (97.5%), the waveform transduced directly through the epidural needle had a pulsatile characteristic as determined by blinded observers. In a total of 53 of 81 epidural catheters (65.4%), the transduced waveform displayed pulsations. Twenty-four of 27 catheters in group S-P/Sims Portex (Smiths Medical MD, Inc, St Paul, MN) (88.9%) transduced a pulsatile tracing from the epidural space, a significantly greater percentage than in the other 2 groups (p = 0.02). The technique of transducing the pressure waveform from the epidural needle inserted in the epidural space is a sensitive and reliable alternative to other techniques for confirmation of correct epidural catheter placement. The technique is simple, sensitive, and inexpensive and uses equipment available in any operating room.
Effects of premature stimulation on HERG K+ channels
Lu, Yu; Mahaut-Smith, Martyn P; Varghese, Anthony; Huang, Christopher L-H; Kemp, Paul R; Vandenberg, Jamie I
2001-01-01
The unusual kinetics of human ether-à-go-go-related gene (HERG) K+ channels are consistent with a role in the suppression of arrhythmias initiated by premature beats. Action potential clamp protocols were used to investigate the effect of premature stimulation on HERG K+ channels, transfected in Chinese hamster ovary cells, at 37 °C. HERG K+ channel currents peaked during the terminal repolarization phase of normally paced action potential waveforms. However, the magnitude of the current and the time point at which conductance was maximal depended on the type of action potential waveform used (epicardial, endocardial, Purkinje fibre or atrial). HERG K+ channel currents recorded during premature action potentials consisted of an early transient outward current followed by a sustained outward current. The magnitude of the transient current component showed a biphasic dependence on the coupling interval between the normally paced and premature action potentials and was maximal at a coupling interval equivalent to 90% repolarization (APD90) for ventricular action potentials. The largest transient current response occurred at shorter coupling intervals for Purkinje fibre (APD90– 20 ms) and atrial (APD90– 30 ms) action potentials. The magnitude of the sustained current response following premature stimulation was similar to that recorded during the first action potential for ventricular action potential waveforms. However, for Purkinje and atrial action potentials the sustained current response was significantly larger during the premature action potential than during the normally paced action potential. A Markov model that included three closed states, one open and one inactivated state with transitions permitted between the pre-open closed state and the inactivated state, successfully reproduced our results for the effects of premature stimuli, both during square pulse and action potential clamp waveforms. These properties of HERG K+ channels may help to suppress arrhythmias initiated by early afterdepolarizations and premature beats in the ventricles, Purkinje fibres or atria. PMID:11744759
Models of brachial to finger pulse wave distortion and pressure decrement.
Gizdulich, P; Prentza, A; Wesseling, K H
1997-03-01
To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by the Finapres technique in 53 adult human subjects. Mean pressure was subtracted from each pressure waveform and Fourier analysis applied to the pulsations. A distortion model was estimated for each subject and averaged over the group. The average inverse model was applied to the full finger pressure waveform. The pressure decrement was modelled by multiple regression on finger systolic and diastolic levels. Waveform distortion could be described by a general, frequency dependent model having a resonance at 7.3 Hz. The general inverse model has an anti-resonance at this frequency. It converts finger to brachial pulsations thereby reducing average waveform distortion from 9.7 (s.d. 3.2) mmHg per sample for the finger pulse to 3.7 (1.7) mmHg for the converted pulse. Systolic and diastolic level differences between finger and brachial arterial pressures changed from -4 (15) and -8 (11) to +8 (14) and +8 (12) mmHg, respectively, after inverse modelling, with pulse pressures correct on average. The pressure decrement model reduced both the mean and the standard deviation of systolic and diastolic level differences to 0 (13) and 0 (8) mmHg. Diastolic differences were thus reduced most. Brachial to finger pulse wave distortion due to wave reflection in arteries is almost identical in all subjects and can be modelled by a single resonance. The pressure decrement due to flow in arteries is greatest for high pulse pressures superimposed on low means.
Levosimendan Prevents Pressure-Overload-induced Right Ventricular Failure.
Hillgaard, Thomas Krarup; Andersen, Asger; Andersen, Stine; Vildbrad, Mads D; Ringgaard, Steffen; Nielsen, Jan M; Nielsen-Kudsk, Jens E
2016-04-01
We investigated if chronic levosimendan treatment can prevent and revert pressure-overload-induced right ventricular hypertrophy and failure in rats. Right ventricular hypertrophy and failure was induced in Wistar rats by pulmonary trunk banding (PTB). The PTB rats were treated with levosimendan (3 mg·kg·d) 3 days before surgery [n = 10, prevention (PREV)], 3 weeks after surgery [n = 10, reversal (REV)] or vehicle (n = 10, VEH). Sham-operated rats received vehicle (n = 16, SHAM). Right ventricular function was evaluated 7 weeks after surgery by echocardiography, magnetic resonance imaging, pressure-volume relations, gross anatomy, and histology. PTB induced right ventricular hypertrophy and compensated heart failure evident by reduced cardiac index (CI) without extra cardiac signs of heart failure. Levosimendan treatment prevented deterioration of right ventricular function measured by CI and right ventricular ejection fraction (RVEF) (CI: VEH vs. PREV 281 ± 17 vs. 362 ± 34 mL·min·kg, P ≤ 0.05, RVEF: VEH vs. PREV 57 ± 2% vs. 68 ± 3%, P ≤ 0.01) to values similar to SHAM (CI: 345 ± 21 mL·min·kg, RVEF: 71 ± 2%). RV contractility was improved in the REV group measured by preload recruitable stroke work (VEH vs. REV 39 ± 3 vs. 66 ± 10 mmHg P ≤ 0.05). Chronic treatment with levosimendan prevents the development of right ventricular failure and improves contractility in established pressure-overload-induced right ventricular failure.
Ventricular beat classifier using fractal number clustering.
Bakardjian, H
1992-09-01
A two-stage ventricular beat 'associative' classification procedure is described. The first stage separates typical beats from extrasystoles on the basis of area and polarity rules. At the second stage, the extrasystoles are classified in self-organised cluster formations of adjacent shape parameter values. This approach avoids the use of threshold values for discrimination between ectopic beats of different shapes, which could be critical in borderline cases. A pattern shape feature conventionally called a 'fractal number', in combination with a polarity attribute, was found to be a good criterion for waveform evaluation. An additional advantage of this pattern classification method is its good computational efficiency, which affords the opportunity to implement it in real-time systems.
Tans, J T; Poortvliet, D C
1988-01-01
Reduction of ventricular size was determined by repeated computed tomography in 30 adult patients shunted for normal pressure hydrocephalus (NPH) and related to the pressure-volume index (PVI) and resistance to outflow of cerebrospinal fluid (Rcsf) measured before shunting. Rapid and marked reduction of ventricular size (n = 10) was associated with a significantly lower PVI than slow and moderate to marked (n = 13) or minimal to mild reduction (n = 7). Otherwise no relationship could be found between the reduction of ventricular size and PVI or Rcsf. It is concluded that both rate and magnitude of reduction of ventricular size after shunting for NPH are extremely variable. High brain elasticity seems to be the best predictor of rapid and marked reduction. PMID:3379425
Eide, Per Kristian
2016-12-01
OBJECTIVE The objective of this study was to examine how pulsatile and static intracranial pressure (ICP) scores correlate with indices of intracranial pressure-volume reserve capacity, i.e., intracranial elastance (ICE) and intracranial compliance (ICC), as determined during ventricular infusion testing. METHODS All patients undergoing ventricular infusion testing and overnight ICP monitoring during the 6-year period from 2007 to 2012 were included in the study. Clinical data were retrieved from a quality registry, and the ventricular infusion pressure data and ICP scores were retrieved from a pressure database. The ICE and ICC (= 1/ICE) were computed during the infusion phase of the infusion test. RESULTS During the period from 2007 to 2012, 82 patients with possible treatment-dependent hydrocephalus underwent ventricular infusion testing within the department of neurosurgery. The infusion tests revealed a highly significant positive correlation between ICE and the pulsatile ICP scores mean wave amplitude (MWA) and rise-time coefficient (RTC), and the static ICP score mean ICP. The ICE was negatively associated with linear measures of ventricular size. The overnight ICP recordings revealed significantly increased MWA (> 4 mm Hg) and RTC (> 20 mm Hg/sec) values in patients with impaired ICC (< 0.5 ml/mm Hg). CONCLUSIONS In this study cohort, there was a significant positive correlation between pulsatile ICP and ICE measured during ventricular infusion testing. In patients with impaired ICC during infusion testing (ICC < 0.5 ml/mm Hg), overnight ICP recordings showed increased pulsatile ICP (MWA > 4 mm Hg, RTC > 20 mm Hg/sec), but not increased mean ICP (< 10-15 mm Hg). The present data support the assumption that pulsatile ICP (MWA and RTC) may serve as substitute markers of pressure-volume reserve capacity, i.e., ICE and ICC.
Beetz, Nadine; Rommel, Carolin; Schnick, Tilman; Neumann, Elena; Lother, Achim; Monroy-Ordonez, Elsa Beatriz; Zeeb, Martin; Preissl, Sebastian; Gilsbach, Ralf; Melchior-Becker, Ariane; Rylski, Bartosz; Stoll, Monika; Schaefer, Liliana; Beyersdorf, Friedhelm; Stiller, Brigitte; Hein, Lutz
2016-12-01
Biglycan, a small leucine-rich proteoglycan, has been shown to play an important role in stabilizing fibrotic scars after experimental myocardial infarction. However, the role of biglycan in the development and regression of cardiomyocyte hypertrophy and fibrosis during cardiac pressure overload and unloading remains elusive. Thus, the aim of the present study was to assess the effect of biglycan on cardiac remodeling in a mouse model of left ventricular pressure overload and unloading. Left ventricular pressure overload induced by transverse aortic constriction (TAC) in mice resulted in left ventricular dysfunction, fibrosis and increased biglycan expression. Fluorescence- and magnetic-assisted sorting of cardiac cell types revealed upregulation of biglycan in the fibroblast population, but not in cardiomyocytes, endothelial cells or leukocytes after TAC. Removal of the aortic constriction (rTAC) after short-term pressure overload (3weeks) improved cardiac contractility and reversed ventricular hypertrophy but not fibrosis in wild-type (WT) mice. Biglycan ablation (KO) enhanced functional recovery but did not resolve cardiac fibrosis. After long-term TAC for 9weeks, ablation of biglycan attenuated the development of cardiac hypertrophy and fibrosis. In vitro, biglycan induced hypertrophy of neonatal rat cardiomyocytes and led to activation of a hypertrophic gene program. Putative downstream mediators of biglycan signaling include Rcan1, Abra and Tnfrsf12a. These genes were concordantly induced by TAC in WT but not in biglycan KO mice. Left ventricular pressure overload induces biglycan expression in cardiac fibroblasts. Ablation of biglycan improves cardiac function and attenuates left ventricular hypertrophy and fibrosis after long-term pressure overload. In vitro biglycan induces hypertrophy of cardiomyocytes, suggesting that biglycan may act as a signaling molecule between cell types to modulate cardiac remodeling. Copyright © 2016 Elsevier Ltd. All rights reserved.
Alastruey, Jordi; Chowienczyk, Phil; Rutten, Marcel C. M.; Segers, Patrick; Schaeffter, Tobias
2017-01-01
Arterial pressure is an important diagnostic parameter for cardiovascular disease. However, relative contributions of individual ventricular and arterial parameters in generating and augmenting pressure are not understood. Using a novel experimental arterial model, our aim was to characterize individual parameter contributions to arterial pressure and its amplification. A piston-driven ventricle provided programmable stroke profiles into various silicone arterial trees and a bovine aorta. Inotropy was varied in the ventricle, and arterial parameters modulated included wall thickness, taper and diameter, the presence of bifurcation, and a native aorta (bovine) versus silicone. Wave reflection at bifurcations was measured and compared with theory, varying parent-to-child tube diameter ratios, and branch angles. Intravascular pressure-tip wires and ultrasonic flow probes measured pressure and flow. Increasing ventricular inotropy independently augmented pressure amplification from 17% to 61% between the lower and higher systolic gradient stroke profiles in the silicone arterial network and from 10% to 32% in the bovine aorta. Amplification increased with presence of a bifurcation, decreasing wall thickness and vessel taper. Pulse pressure increased with increasing wall thickness (stiffness) and taper angle and decreasing diameter. Theoretical predictions of wave transmission through bifurcations werre similar to measurements (correlation: 0.91, R2 = 0.94) but underestimated wave reflection (correlation: 0.75, R2 = 0.94), indicating energy losses during mechanical wave reflection. This study offers the first comprehensive investigation of contributors to hypertensive pressure and its propagation throughout the arterial tree. Importantly, ventricular inotropy plays a crucial role in the amplification of peripheral pressure wave, which offers opportunity for noninvasive assessment of ventricular health. NEW & NOTEWORTHY The present study distinguishes contributions from cardiac and arterial parameters to elevated blood pressure and pressure amplification. Most importantly, it offers the first evidence that ventricular inotropy, an indicator of ventricular function, is an independent determinant of pressure amplification and could be measured with such established devices such as the SphygmoCor. PMID:28576835
Gaddum, Nicholas; Alastruey, Jordi; Chowienczyk, Phil; Rutten, Marcel C M; Segers, Patrick; Schaeffter, Tobias
2017-09-01
Arterial pressure is an important diagnostic parameter for cardiovascular disease. However, relative contributions of individual ventricular and arterial parameters in generating and augmenting pressure are not understood. Using a novel experimental arterial model, our aim was to characterize individual parameter contributions to arterial pressure and its amplification. A piston-driven ventricle provided programmable stroke profiles into various silicone arterial trees and a bovine aorta. Inotropy was varied in the ventricle, and arterial parameters modulated included wall thickness, taper and diameter, the presence of bifurcation, and a native aorta (bovine) versus silicone. Wave reflection at bifurcations was measured and compared with theory, varying parent-to-child tube diameter ratios, and branch angles. Intravascular pressure-tip wires and ultrasonic flow probes measured pressure and flow. Increasing ventricular inotropy independently augmented pressure amplification from 17% to 61% between the lower and higher systolic gradient stroke profiles in the silicone arterial network and from 10% to 32% in the bovine aorta. Amplification increased with presence of a bifurcation, decreasing wall thickness and vessel taper. Pulse pressure increased with increasing wall thickness (stiffness) and taper angle and decreasing diameter. Theoretical predictions of wave transmission through bifurcations werre similar to measurements (correlation: 0.91, R 2 = 0.94) but underestimated wave reflection (correlation: 0.75, R 2 = 0.94), indicating energy losses during mechanical wave reflection. This study offers the first comprehensive investigation of contributors to hypertensive pressure and its propagation throughout the arterial tree. Importantly, ventricular inotropy plays a crucial role in the amplification of peripheral pressure wave, which offers opportunity for noninvasive assessment of ventricular health. NEW & NOTEWORTHY The present study distinguishes contributions from cardiac and arterial parameters to elevated blood pressure and pressure amplification. Most importantly, it offers the first evidence that ventricular inotropy, an indicator of ventricular function, is an independent determinant of pressure amplification and could be measured with such established devices such as the SphygmoCor. Copyright © 2017 the American Physiological Society.
Single pulse analysis of intracranial pressure for a hydrocephalus implant.
Elixmann, I M; Hansinger, J; Goffin, C; Antes, S; Radermacher, K; Leonhardt, S
2012-01-01
The intracranial pressure (ICP) waveform contains important diagnostic information. Changes in ICP are associated with changes of the pulse waveform. This change has explicitly been observed in 13 infusion tests by analyzing 100 Hz ICP data. An algorithm is proposed which automatically extracts the pulse waves and categorizes them into predefined patterns. A developed algorithm determined 88 %±8 % (mean ±SD) of all classified pulse waves correctly on predefined patterns. This algorithm has low computational cost and is independent of a pressure drift in the sensor by using only the relationship between special waveform characteristics. Hence, it could be implemented on a microcontroller of a future electromechanic hydrocephalus shunt system to control the drainage of cerebrospinal fluid (CSF).
Pro-arrhythmic effects of low plasma [K+] in human ventricle: An illustrated review.
Trenor, Beatriz; Cardona, Karen; Romero, Lucia; Gomez, Juan F; Saiz, Javier; Rajamani, Sridharan; Belardinelli, Luiz; Giles, Wayne
2018-05-01
Potassium levels in the plasma, [K + ] o , are regulated precisely under physiological conditions. However, increases (from approx. 4.5 to 8.0mM) can occur as a consequence of, e.g., endurance exercise, ischemic insult or kidney failure. This hyperkalemic modulation of ventricular electrophysiology has been studied extensively. Hypokalemia is also common. It can occur in response to diuretic therapy, following renal dialysis, or during recovery from endurance exercise. In the human ventricle, clinical hypokalemia (e.g., [K + ] o levels of approx. 3.0mM) can cause marked changes in both the resting potential and the action potential waveform, and these may promote arrhythmias. Here, we provide essential background information concerning the main K + -sensitive ion channel mechanisms that act in concert to produce prominent short-term ventricular electrophysiological changes, and illustrate these by implementing recent mathematical models of the human ventricular action potential. Even small changes (~1mM) in [K + ] o result in significant alterations in two different K + currents, I K1 and HERG. These changes can markedly alter in resting membrane potential and/or action potential waveform in human ventricle. Specifically, a reduction in net outward transmembrane K + currents (repolarization reserve) and an increased substrate input resistance contribute to electrophysiological instability during the plateau of the action potential and may promote pro-arrhythmic early after-depolarizations (EADs). Translational settings where these insights apply include: optimal diuretic therapy, and the interpretation of data from Phase II and III trials for anti-arrhythmic drug candidates. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Derzsi, Aranka; Bruneau, Bastien; Gibson, Andrew Robert; Johnson, Erik; O'Connell, Deborah; Gans, Timo; Booth, Jean-Paul; Donkó, Zoltán
2017-03-01
Low-pressure capacitively coupled radio frequency discharges operated in O2 and driven by tailored voltage waveforms are investigated experimentally and by means of kinetic simulations. Pulse-type (peaks/valleys) and sawtooth-type voltage waveforms that consist of up to four consecutive harmonics of the fundamental frequency are used to study the amplitude asymmetry effect as well as the slope asymmetry effect at different fundamental frequencies (5, 10, and 15 MHz) and at different pressures (50-700 mTorr). Values of the DC self-bias determined experimentally and spatio-temporal excitation rates derived from phase resolved optical emission spectroscopy measurements are compared with particle-in-cell/Monte Carlo collisions simulations. The spatio-temporal distributions of the excitation rate obtained from experiments are well reproduced by the simulations. Transitions of the discharge electron heating mode from the drift-ambipolar mode to the α-mode are induced by changing the number of consecutive harmonics included in the driving voltage waveform or by changing the gas pressure. Changing the number of harmonics in the waveform has a strong effect on the electronegativity of the discharge, on the generation of the DC self-bias and on the control of ion properties at the electrodes, both for pulse-type, as well as sawtooth-type driving voltage waveforms The effect of the surface quenching rate of oxygen singlet delta metastable molecules on the spatio-temporal excitation patterns is also investigated.
Diastolic blood pressure-estimated left ventricular dp/dt.
Yilmaz, Hüseyin; Minareci, Kenan; Kabukçu, Mehmet; Sancaktar, Oktay
2002-02-01
Peak dp/dt is one of the best isovolumic phase indexes of the myocardial contractile state requiring invasive procedures or presence of mitral regurgitation severe enough to measure in clinical practice by Doppler echocardiography. In this study, we sought the correlation between two noninvasive methods of measurements for left ventricular dp/dt-diastolic blood pressure- (DBP) estimated and continuous-wave Doppler-derived dp/dt-min electrocardiographic/echocardiographic study to emphasize the clinical feasibility of the DBP-estimated method. Thirty-six randomized patients (27 male, 9 female; 58 +/- 8 years) with mild mitral regurgitation were enrolled in this study. DBP-estimated dp/dt was calculated from DBP minus the left ventricular end-diastolic pressure (LVEDP) over the isovolumetric contraction time (IVCT). LVEDP was assumed to be 10 mmHg for all patients. Doppler-determined left ventricular dp/dt was derived from the continuous-wave Doppler spectrum of mitral regurgitation jet by dividing the magnitude of the left ventricular atrial pressure gradient rise between 1 mm/sec-3 mm/sec of mitral regurgitant velocity signal by the time taken for this change. Left ventricular dp/dt by Doppler was 1122 +/- 303 mmHg/sec and blood pressure-estimated dp/dt was 1063 +/- 294 mmHg/sec. There was a high correlation (r = 0.97, P < 0.001) of dp/dt between the two techniques. DBP and IVCT can generate left ventricular dp/dt without invasive procedures, even in the absence of mitral regurgitation in clinical practice.
Annular subvalvular left ventricular aneurysm in Bahia, Brazil.
Guimarães, A C; Filho, A S; Esteves, J P; Abreu, W N; Vinhaes, L A; de Almeida Souza, J A; Machado, A
1976-01-01
Two cases of left ventricular aneurysm, a 16-year-old black boy and a 23-year-old white girl, from Bahia, Brazil, are presented. In both patients there was enlargement of the cardiac silhouette and a prominent bulge of the left inferior border. On the right oblique view a ring of calcium at the ventricular opening of the aneurysms was visualized. A left ventriculogram showed a huge aneurysm in the first case and a bulge on the lateral wall of the left ventricle in the other. Cardiac catheterization showed a rise in left and right ventricular end-diastolic pressures and in the mean pulmonary artery pressure. In the first case the contour of the right ventricular pressure curve showed a restrictive pattern. The similarities of these aneurysms with the annular submitral type described in young black Africans are stressed. Images PMID:973882
Annular subvalvular left ventricular aneurysm in Bahia, Brazil.
Guimarães, A C; Filho, A S; Esteves, J P; Abreu, W N; Vinhaes, L A; de Almeida Souza, J A; Machado, A
1976-10-01
Two cases of left ventricular aneurysm, a 16-year-old black boy and a 23-year-old white girl, from Bahia, Brazil, are presented. In both patients there was enlargement of the cardiac silhouette and a prominent bulge of the left inferior border. On the right oblique view a ring of calcium at the ventricular opening of the aneurysms was visualized. A left ventriculogram showed a huge aneurysm in the first case and a bulge on the lateral wall of the left ventricle in the other. Cardiac catheterization showed a rise in left and right ventricular end-diastolic pressures and in the mean pulmonary artery pressure. In the first case the contour of the right ventricular pressure curve showed a restrictive pattern. The similarities of these aneurysms with the annular submitral type described in young black Africans are stressed.
Aerodynamic and acoustic effects of ventricular gap.
Alipour, Fariborz; Karnell, Michael
2014-03-01
Supraglottic compression is frequently observed in individuals with dysphonia. It is commonly interpreted as an indication of excessive circumlaryngeal muscular tension and ventricular medialization. The purpose of this study was to describe the aerodynamic and acoustic impact of varying ventricular medialization in a canine model. Subglottal air pressure, glottal airflow, electroglottograph, acoustic signals, and high-speed video images were recorded in seven excised canine larynges mounted in vitro for laryngeal vibratory experimentation. The degree of gap between the ventricular folds was adjusted and measured using sutures and weights. Data were recorded during phonation when the ventricular gap was narrow, neutral, and large. Glottal resistance was estimated by measures of subglottal pressure and glottal flow. Glottal resistance increased systematically as ventricular gap became smaller. Wide ventricular gaps were associated with increases in fundamental frequency and decreases in glottal resistance. Sound pressure level did not appear to be impacted by the adjustments in ventricular gap used in this research. Increases in supraglottic compression and associated reduced ventricular width may be observed in a variety of disorders that affect voice quality. Ventricular compression may interact with true vocal fold posture and vibration resulting in predictable changes in aerodynamic, physiological, acoustic, and perceptual measures of phonation. The data from this report supports the theory that narrow ventricular gaps may be associated with disordered phonation. In vitro and in vivo human data are needed to further test this association. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Method to produce American Thoracic Society flow-time waveforms using a mechanical pump.
Hankinson, J L; Reynolds, J S; Das, M K; Viola, J O
1997-03-01
The American Thoracic Society (ATS) recently adopted a new set of 26 standard flow-time waveforms for use in testing both diagnostic and monitoring devices. Some of these waveforms have a higher frequency content than present in the ATS-24 standard volume-time waveforms, which, when produced by a mechanical pump, may result in a pump flow output that is less than the desired flow due to gas compression losses within the pump. To investigate the effects of gas compression, a mechanical pump was used to generate the necessary flows to test mini-Wright and Assess peak expiratory flow (PEF) meters. Flow output from the pump was measured by two different independent methods, a pneumotachometer and a method based on piston displacement and pressure measured within the pump. Measuring output flow based on piston displacement and pressure has been validated using a pneumotachometer and mini-Wright PEF meter, and found to accurately measure pump output. This method introduces less resistance (lower back-pressure) and dead space volume than using a pneumotachometer in series with the meter under test. Pump output flow was found to be lower than the desired flow both with the mini-Wright and Assess meters (for waveform No. 26, PEFs 7.1 and 10.9% lower, respectively). To compensate for losses due to gas compression, we have developed a method of deriving new input waveforms, which, when used to drive a commercially available mechanical pump, accurately and reliably produces the 26 ATS flow-time waveforms, even those with the fastest rise-times.
Vikholm, Per; Schiller, Petter; Hellgren, Laila
2014-01-01
OBJECTIVES Right ventricular failure after left ventricular assist device implantation is a serious complication with high rates of mortality and morbidity. It has been demonstrated in experimental settings that volume exclusion of the right ventricle with a modified Glenn shunt can improve haemodynamics during ischaemic right ventricular failure. However, the concept of a modified Glenn shunt is dependent on a normal pulmonary vascular resistance, which can limit its use in some patients. The aim of this study was to explore the effects of volume exclusion with a modified Glenn shunt during right ventricular failure due to pulmonary banding, and to study the alterations in genetic expression in the right ventricle due to pressure and volume overload. METHODS Experimental right ventricular failure was induced in pigs (n = 11) through 2 h of pulmonary banding. The pigs were randomized to either treatment with a modified Glenn shunt and pulmonary banding (n = 6) or solely pulmonary banding (n = 5) as a control group. Haemodynamic measurements, blood samples and right ventricular biopsies for genetic analysis were sampled at baseline, at right ventricular failure (i.e. 2 h of pulmonary banding) and 1 h post-right ventricular failure in both groups. RESULTS Right atrial pressure increased from 10 mmHg (9.0–12) to 18 mmHg (16–22) (P < 0.01) and the right ventricular pressure from 31 mmHg (26–35) to 57 mmHg (49–61) (P < 0.01) after pulmonary banding. Subsequent treatment with the modified Glenn shunt resulted in a decrease in right atrial pressure to 13 mmHg (11–14) (P = 0.03). In the control group, right atrial pressure was unchanged at 19 mmHg (16–20) (P = 0.18). At right heart failure, there was an up-regulation of genes associated with heart failure, inflammation, angiogenesis, negative regulation of cell death and proliferation. CONCLUSIONS Volume exclusion with a modified Glenn shunt during right ventricular failure reduced venous congestion compared with the control group. The state of right heart failure was verified through genetic expressional changes. PMID:24396048
Kral Kollars, Catharine A; Gelehrter, Sarah; Bove, Edward L; Ensing, Gregory
2010-03-01
Congenitally corrected transposition of the great arteries (CCTGA) is associated with tricuspid regurgitation (TR), which has been postulated to arise from the effect of ventricular septal position on the attachments of the tricuspid valve. This study was performed to determine the effect of left ventricular (LV) pressure on right ventricular (RV) and LV geometry and the degree of TR. Serial echocardiograms were reviewed from, 30 patients with CCTGA who underwent pulmonary artery banding to train the morphologic left ventricle (n = 14) or left ventricle-to-pulmonary artery conduit placement and ventricular septal defect closure in conjunction with physiologic repair (n = 16). The degree of TR, the LV/RV pressure ratio, RV and LV sphericity indexes, and tricuspid valve tethering distance and coaptation length were analyzed. After pulmonary artery banding, an increase in LV systolic pressure to > or =2/3 systemic resulted in a decrease in TR from severe to moderate (p = 0.02). The percentage of patients with severe TR decreased from 64% to 18% (p = 0.06). The RV sphericity index decreased (p = 0.05), and the LV sphericity index increased (p = 0.02). After left ventricle-to-pulmonary artery conduit placement, a decrease in LV pressure to < or =1/2 systemic resulted in an increase in TR from none to mild (p = 0.003). In conclusion, these data indicate that LV pressure in patients with CCTGA affects the degree of TR and that septal shift caused by changes in LV and RV pressure is an important mechanism. Copyright 2010. Published by Elsevier Inc.
Pulse transit time differential measurement by fiber Bragg grating pulse recorder.
Umesh, Sharath; Padma, Srivani; Ambastha, Shikha; Kalegowda, Anand; Asokan, Sundarrajan
2015-05-01
The present study reports a noninvasive technique for the measurement of the pulse transit time differential (PTTD) from the pulse pressure waveforms obtained at the carotid artery and radial artery using fiber Bragg grating pulse recorders (FBGPR). PTTD is defined as the time difference between the arrivals of a pulse pressure waveform at the carotid and radial arterial sites. The PTTD is investigated as an indicator of variation in the systolic blood pressure. The results are validated against blood pressure variation obtained from a Mindray Patient Monitor. Furthermore, the pulse wave velocity computed from the obtained PTTD is compared with the pulse wave velocity obtained from the color Doppler ultrasound system and is found to be in good agreement. The major advantage of the PTTD measurement via FBGPRs is that the data acquisition system employed can simultaneously acquire pulse pressure waveforms from both FBGPRs placed at carotid and radial arterial sites with a single time scale, which eliminates time synchronization complexity.
Smerup, Morten; Damkjær, Mads; Brøndum, Emil; Baandrup, Ulrik T; Kristiansen, Steen Buus; Nygaard, Hans; Funder, Jonas; Aalkjær, Christian; Sauer, Cathrine; Buchanan, Rasmus; Bertelsen, Mads Frost; Østergaard, Kristine; Grøndahl, Carsten; Candy, Geoffrey; Hasenkam, J Michael; Secher, Niels H; Bie, Peter; Wang, Tobias
2016-02-01
Giraffes--the tallest extant animals on Earth--are renowned for their high central arterial blood pressure, which is necessary to secure brain perfusion. Arterial pressure may exceed 300 mmHg and has historically been attributed to an exceptionally large heart. Recently, this has been refuted by several studies demonstrating that the mass of giraffe heart is similar to that of other mammals when expressed relative to body mass. It thus remains unexplained how the normal-sized giraffe heart generates such massive arterial pressures. We hypothesized that giraffe hearts have a small intraventricular cavity and a relatively thick ventricular wall, allowing for generation of high arterial pressures at normal left ventricular wall tension. In nine anaesthetized giraffes (495±38 kg), we determined in vivo ventricular dimensions using echocardiography along with intraventricular and aortic pressures to calculate left ventricular wall stress. Cardiac output was also determined by inert gas rebreathing to provide an additional and independent estimate of stroke volume. Echocardiography and inert gas-rebreathing yielded similar cardiac outputs of 16.1±2.5 and 16.4±1.4 l min(-1), respectively. End-diastolic and end-systolic volumes were 521±61 ml and 228±42 ml, respectively, yielding an ejection fraction of 56±4% and a stroke volume of 0.59 ml kg(-1). Left ventricular circumferential wall stress was 7.83±1.76 kPa. We conclude that, relative to body mass, a small left ventricular cavity and a low stroke volume characterizes the giraffe heart. The adaptations result in typical mammalian left ventricular wall tensions, but produce a lowered cardiac output. © 2016. Published by The Company of Biologists Ltd.
Neilan, Tomas G.; Farhad, Hoshang; Dodson, John A.; Shah, Ravi V.; Abbasi, Siddique A.; Bakker, Jessie P.; Michaud, Gregory F.; van der Geest, Rob; Blankstein, Ron; Steigner, Michael; John, Roy M.; Jerosch‐Herold, Michael; Malhotra, Atul; Kwong, Raymond Y.
2013-01-01
Background Sleep apnea (SA) is associated with an increased risk of atrial fibrillation (AF). We sought to determine the effect of SA on cardiac structure in patients with AF, whether therapy for SA was associated with beneficial cardiac structural remodelling, and whether beneficial cardiac structural remodelling translated into a reduced risk of recurrence of AF after pulmonary venous isolation (PVI). Methods and Results A consecutive group of 720 patients underwent a cardiac magnetic resonance study before PVI. Patients with SA (n=142, 20%) were more likely to be male, diabetic, and hypertensive and have an increased pulmonary artery pressure, right ventricular volume, atrial dimensions, and left ventricular mass. Treated SA was defined as duration of continuous positive airway pressure therapy of >4 hours per night. Treated SA patients (n=71, 50%) were more likely to have paroxysmal AF, a lower blood pressure, lower ventricular mass, and smaller left atrium. During a follow‐up of 42 months, AF recurred in 245 patients. The cumulative incidence of AF recurrence was 51% in patients with SA, 30% in patients without SA, 68% in patients with untreated SA, and 35% in patients with treated SA. In a multivariable model, the presence of SA (hazard ratio 2.79, CI 1.97 to 3.94, P<0.0001) and untreated SA (hazard ratio 1.61, CI 1.35 to 1.92, P<0.0001) were highly associated with AF recurrence. Conclusions Patients with SA have an increased blood pressure, pulmonary artery pressure, right ventricular volume, left atrial size, and left ventricular mass. Therapy with continuous positive airway pressure is associated with lower blood pressure, atrial size, and ventricular mass, and a lower risk of AF recurrence after PVI. PMID:24275628
Gan, Rong Z.; Nakmali, Don; Ji, Xiao D.; Leckness, Kegan; Yokell, Zachary
2016-01-01
Mechanical damage to middle ear components in blast exposure directly causes hearing loss, and the rupture of the tympanic membrane (TM) is the most frequent injury of the ear. However, it is unclear how the severity of injury graded by different patterns of TM rupture is related to the overpressure waveforms induced by blast waves. In the present study, the relationship between the TM rupture threshold and the impulse or overpressure waveform has been investigated in chinchillas. Two groups of animals were exposed to blast overpressure simulated in our lab under two conditions: open field and shielded with a stainless steel cup covering the animal head. Auditory brainstem response (ABR) and wideband tympanometry were measured before and after exposure to check the hearing threshold and middle ear function. Results show that waveforms recorded in the shielded case were different from those in the open field and the TM rupture threshold in the shielded case was lower than that in the open field (3.4±0.7 vs. 9.1±1.7 psi or 181±1.6 vs. 190±1.9 dB SPL). The impulse pressure energy spectra analysis of waveforms demonstrates that the shielded waveforms include greater energy at high frequencies than that of the open field waves. Finally, a 3D finite element (FE) model of the chinchilla ear was used to compute the distributions of stress in the TM and the TM displacement with impulse pressure waves. The FE model-derived change of stress in response to pressure loading in the shielded case was substantially faster than that in the open case. This finding provides the biomechanical mechanisms for blast induced TM damage in relation to overpressure waveforms. The TM rupture threshold difference between the open and shielded cases suggests that an acoustic role of helmets may exist, intensifying ear injury during blast exposure. PMID:26807796
Pulsatile pipe flow transition: Flow waveform effects
NASA Astrophysics Data System (ADS)
Brindise, Melissa C.; Vlachos, Pavlos P.
2018-01-01
Although transition is known to exist in various hemodynamic environments, the mechanisms that govern this flow regime and their subsequent effects on biological parameters are not well understood. Previous studies have investigated transition in pulsatile pipe flow using non-physiological sinusoidal waveforms at various Womersley numbers but have produced conflicting results, and multiple input waveform shapes have yet to be explored. In this work, we investigate the effect of the input pulsatile waveform shape on the mechanisms that drive the onset and development of transition using particle image velocimetry, three pulsatile waveforms, and six mean Reynolds numbers. The turbulent kinetic energy budget including dissipation rate, production, and pressure diffusion was computed. The results show that the waveform with a longer deceleration phase duration induced the earliest onset of transition, while the waveform with a longer acceleration period delayed the onset of transition. In accord with the findings of prior studies, for all test cases, turbulence was observed to be produced at the wall and either dissipated or redistributed into the core flow by pressure waves, depending on the mean Reynolds number. Turbulent production increased with increasing temporal velocity gradients until an asymptotic limit was reached. The turbulence dissipation rate was shown to be independent of mean Reynolds number, but a relationship between the temporal gradients of the input velocity waveform and the rate of turbulence dissipation was found. In general, these results demonstrated that the shape of the input pulsatile waveform directly affected the onset and development of transition.
2014-03-01
waveforms that are easier to measure than ABP (e.g., pulse oximeter waveforms); (3) a NIH SBIR Phase I proposal with Retia Medical to develop automated...the training dataset. Integrating the technique with non-invasive pulse transit time (PTT) was most effective. The integrated technique specifically...the peripheral ABP waveforms in the training dataset. These techniques included the rudimentary mean ABP technique, the classic pulse pressure times
Development of optoelectronic monitoring system for ear arterial pressure waveforms
NASA Astrophysics Data System (ADS)
Sasayama, Satoshi; Imachi, Yu; Yagi, Tamotsu; Imachi, Kou; Ono, Toshirou; Man-i, Masando
1994-02-01
Invasive intra-arterial blood pressure measurement is the most accurate method but not practical if the subject is in motion. The apparatus developed by Wesseling et al., based on a volume-clamp method of Penaz (Finapres), is able to monitor continuous finger arterial pressure waveforms noninvasively. The limitation of Finapres is the difficulty in measuring the pressure of a subject during work that involves finger or arm action. Because the Finapres detector is attached to subject's finger, the measurements are affected by inertia of blood and hydrostatic effect cause by arm or finger motion. To overcome this problem, the authors made a detector that is attached to subject's ear and developed and optoelectronic monitoring systems for ear arterial pressure waveform (Earpres). An IR LEDs, photodiode, and air cuff comprised the detector. The detector was attached to a subject's ear, and the space adjusted between the air cuff and the rubber plate on which the LED and photodiode were positioned. To evaluate the accuracy of Earpres, the following tests were conducted with participation of 10 healthy male volunteers. The subjects rested for about five minutes, then performed standing and squatting exercises to provide wide ranges of systolic and diastolic arterial pressure. Intra- and inter-individual standard errors were calculated according to the method of van Egmond et al. As a result, average, the averages of intra-individual standard errors for earpres appeared small (3.7 and 2.7 mmHg for systolic and diastolic pressure respectively). The inter-individual standard errors for Earpres were about the same was Finapres for both systolic and diastolic pressure. The results showed the ear monitor was reliable in measuring arterial blood pressure waveforms and might be applicable to various fields such as sports medicine and ergonomics.
Li, K; Qiao, J; Zhao, L; Dong, S; Ou, D; Wang, J; Wang, H; Xu, T
2006-11-01
Right ventricular hypertrophy and failure is an important step in the development of ascites syndrome (AS) in broiler chickens. Cytoplasmic calcium concentration is a major regulator of cardiac contractile function and various physiological processes in cardiac muscle cells. The purpose of this study was to measure the right ventricular pressure and investigate the precise ultrastructural location of Ca(2+) and Ca(2+)-ATPase in the right ventricular myocardium of chickens with AS induced by low ambient temperature. The results showed that the right ventricular diastolic pressure of ascitic broilers was significantly higher than that of control broilers (P < 0.01), and the maximum change ratio of right intraventricular pressure (RV +/- dp/dt(max)) of ascitic broilers was significantly lower than that of the controls (P < 0.01). Extensively increased calcium deposits were observed in the right ventricular myocardium of ascitic broilers, whereas in the age-matched control broilers, calcium deposits were much less. The Ca(2+)-ATPase reactive products were obviously found on the sarcoplasmic reticulum and mitochondrial membrane of the control right ventricular myocardium, but rarely observed in the ascitic broilers. The data suggest that in ascitic broilers there is the right ventricular diastolic dysfunction, in which the overload of intracellular calcium and the decreased Ca(2+)-ATPase activity might be the important factors.
Non-selective His bundle pacing with a biphasic waveform: enhancing septal resynchronization.
Ortega, Daniel F; Barja, Luis D; Logarzo, Emilio; Mangani, Nicolas; Paolucci, Analia; Bonomini, Maria P
2018-05-01
His bundle pacing has shown to prevent detrimental effects from right ventricular apical pacing (RVA) and proved to resynchronize many conduction disturbances cases. However, the extent of His bundle pacing resynchronization is limited. An optimized stimulation waveform could expand this limit when implemented in His bundle pacing sets. In this work, we temporarily implemented RVA and Non-selective His bundle pacing with a biphasic anodal-first waveform (AF-nHB) and compared their effects against sinus rhythm (SR). Fifteen patients referred for electrophysiologic study with conduction disturbances, cardiomyopathy and ejection fraction below 35% were enrolled for the study. The following acute parameters were measured: QRS duration, left ventricular activation (RLVT), time of isovolumic contraction (IVCT), ejection fraction (EF), and dP/dtmax. QRS duration and RLVT decreased markedly under AF-nHB (SR: 169 ± 34 ms vs. nHB: 116 ± 31 ms, P < 0.0005) while RVA significantly increased QRS duration (SR: 169 ms vs. RVA: 198 ms, P < 0.05) and did not change RLVT (P = NS). Consistently, IVCT moderately decreased under AF-nHB (SR: 238 ms vs. RVA: 184 ms, P < 0.05 vs. SR) and dP/dtmax showed a 93.35 [mmHg] average increase under AF-nHB against SR. Also, T-wave inversions were observed during AF-nHB immediately after SR and RVA pacing suggesting the occurrence of cardiac memory. AF-nHB corrected bundle branch blocks in patients with severe conduction disturbances, even in those with dilated cardiomiopathy, outstanding from RVA. Also, the occurrence of cardiac memory during AF-nHB turned up as an observational finding of this study.
Bonnes, Judith L; Keuper, Wessel; Westra, Sjoerd W; Zegers, Erwin S; Oostendorp, Thom F; Brouwer, Marc A; Smeets, Joep L R M
2015-01-01
Ventricular fibrillation (VF) waveform characteristics are associated with cardiac arrest duration and defibrillation success. Recent animal studies found that VF characteristics and shock success also depend on the presence of myocardial infarction (MI). In patients, VF induction after implantable cardioverter defibrillator (ICD) implantation offers a unique setting to study early VF characteristics: we studied the relation with cardiac disease--either presence or absence of a previous MI--and with shock success. Retrospective cohort study of ICD-patients who underwent defibrillation testing, 117 (63%) with and 69 (37%) without a previous MI. Intracardiac recordings of induced VF were analysed using Fourier analysis. In previous MI-patients, the fundamental frequency and organisation index of the VF signal were significantly lower as compared with patients without a previous MI: 4.9 Hz ± 0.6 vs. 5.2 Hz ± 0.6 (p = 0.005) and 56% ± 10 vs. 60% ± 9 (p = 0.001), respectively. The median frequency was not different (p = 0.25). We found no association between VF characteristics and ICD shock success. In analogy with observations in animals, we found that a history of a previous MI was associated with slower and less organised VF. In our cohort of ICD-patients, early VF waveform characteristics were not associated with shock outcomes. Further study is warranted to determine to what extent VF characteristics are influenced by the underlying aetiology on the one hand, and time delay on the other. These findings could improve insight into the potential value of VF analysis to guide shock delivery. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Feedback control for stabilizing chaotic spiral waves during cardiac ventricular fibrillation
NASA Astrophysics Data System (ADS)
Uzelac, Ilija; Wikswo, John; Gray, Richard
2011-03-01
The cardiac arrhythmias that lead to ventricular fibrillation (VF) arise from electrical spiral waves (SW) rotating within the heart with a characteristic period τ . A single drifting SW can degenerate into a chaotic system of multiple SWs and VF. Hence early SW detection and termination is crucial to prevent VF. Time-delayed feedback control (TDFC) is well known approach for stabilizing unstable periodic orbits embedded in chaotic attractors. We hypothesize that cardiac SWs can be stabilized by TDFC with a time-delay of τ . Implementing this approach will require precise, closed-loop control of the charge delivered to the heart during the defibrillation process. To do this, we have developed a 2 kW arbitrary-waveform voltage-to-current converter (V2CC) with a 1 kHz bandwidth that can deliver up to 5 A at 400 V for 500 ms, and a photodiode system for recording in real time an optical electrocardiogram, OECG(t). The feedback signal driving the V2CC will be the time-difference (OECG(t) - OECG(t-T), where we hypothesize that T is τ , the period of the SW. This may dramatically decrease defibrillation voltages by using a defibrillation waveform customized to the VF event, unlike commercial capacitor defibrillators. Supported in part by NIH R01 HL58241-11 through ARRA 2009.
Park, Jun I K; Heikhmakhtiar, Aulia Khamas; Kim, Chang Hyun; Kim, Yoo Seok; Choi, Seong Wook; Song, Kwang Soup; Lim, Ki Moo
2018-05-22
Although it is important to analyze the hemodynamic factors related to the right ventricle (RV) after left ventricular assist device (LVAD) implantation, previous studies have focused only on the alteration of the ventricular shape and lack quantitative analysis of the various hemodynamic parameters. Therefore, we quantitatively analyzed various hemodynamic parameters related to the RV under normal, heart failure (HF), and HF incorporated with continuous flow LVAD therapy by using a computational model. In this study, we combined a three-dimensional finite element electromechanical model of ventricles, which is based on human ventricular morphology captured by magnetic resonance imaging (MRI) with a lumped model of the circulatory system and continuous flow LVAD function in order to construct an integrated model of an LVAD implanted-cardiovascular system. To induce systolic dysfunction, the magnitude of the calcium transient function under HF condition was reduced to 70% of the normal value, and the time constant was reduced by 30% of the normal value. Under the HF condition, the left ventricular end systolic pressure decreased, the left ventricular end diastolic pressure increased, and the pressure in the right atrium (RA), RV, and pulmonary artery (PA) increased compared with the normal condition. The LVAD therapy decreased the end-systolic pressure of the LV by 41%, RA by 29%, RV by 53%, and PA by 71%, but increased the right ventricular ejection fraction by 52% and cardiac output by 40%, while the stroke work was reduced by 67% compared with the HF condition without LVAD. The end-systolic ventricular tension and strain decreased with the LVAD treatment. LVAD enhances CO and mechanical unloading of the LV as well as those of the RV and prevents pulmonary hypertension which can be induced by HF.
Long-term results after left ventricular aneurysmectomy.
Otterstad, J E; Christensen, O; Levorstad, K; Nitter-Hauge, S
1981-01-01
Twenty-six patients (21 men and five women) with a mean age of 54.8 years have been reinvestigated nine to 62 months (mean 29.7) after left ventricular aneurysmectomy. Preoperatively left ventricular angiography disclosed an anterior aneurysm in all cases, which was large in 15 (57%) and small to medium in 11 (42%). At follow-up a large residual aneurysm was found in five (19%), a small to medium one in 13 (50%), and akinesia without aneurysm in eight (31%). The sum of ST elevation (sigma ST) in praecordial leads in the electrocardiogram was reduced from a mean value of 11.2 mm to 7.7 mm. In no patient did ST segments return to normal after operation. Preoperatively, mean sigma ST was identical in patients with large and with small to medium aneurysms. At reinvestigation mean sigma ST was identical in patients with large and with small to medium residual aneurysms as well as in patients with akinesia. Left ventricular end-diastolic pressure before angiography was reduced from a mean value of 21.5 mm to 15.1 mmHg and after angiography from 26.7 mm to 21.1 mmHg. Progression of coronary artery stenoses was a characteristic finding in patients whose left ventricular end-diastolic pressures did not return to normal. These patients had a longer follow-up time than those with no progression of coronary disease, who all showed an improvement in left ventricular end-diastolic pressure. Six patients who had coronary bypass grafting performed had unchanged left ventricular end-diastolic pressures at follow-up. The results indicate that progression of coronary artery disease may be responsible for an eventual further deterioration in left ventricular function after aneurysmectomy. Additional bypass grafting did not result in improved left ventricular function. PMID:6971647
NASA Technical Reports Server (NTRS)
Ocasio, W. C.; Rigney, D. R.; Clark, K. P.; Mark, R. G.; Goldberger, A. L. (Principal Investigator)
1993-01-01
We describe the theory and computer implementation of a newly-derived mathematical model for analyzing the shape of blood pressure waveforms. Input to the program consists of an ECG signal, plus a single continuous channel of peripheral blood pressure, which is often obtained invasively from an indwelling catheter during intensive-care monitoring or non-invasively from a tonometer. Output from the program includes a set of parameter estimates, made for every heart beat. Parameters of the model can be interpreted in terms of the capacitance of large arteries, the capacitance of peripheral arteries, the inertance of blood flow, the peripheral resistance, and arterial pressure due to basal vascular tone. Aortic flow due to contraction of the left ventricle is represented by a forcing function in the form of a descending ramp, the area under which represents the stroke volume. Differential equations describing the model are solved by the method of Laplace transforms, permitting rapid parameter estimation by the Levenberg-Marquardt algorithm. Parameter estimates and their confidence intervals are given in six examples, which are chosen to represent a variety of pressure waveforms that are observed during intensive-care monitoring. The examples demonstrate that some of the parameters may fluctuate markedly from beat to beat. Our program will find application in projects that are intended to correlate the details of the blood pressure waveform with other physiological variables, pathological conditions, and the effects of interventions.
Pulse pressure waveform in hydrocephalus: what it is and what it isn't.
Czosnyka, Marek; Czosnyka, Zofia; Keong, Nicole; Lavinio, Andreas; Smielewski, Piotr; Momjian, Shahan; Schmidt, Eric A; Petrella, Gianpaolo; Owler, Brian; Pickard, John D
2007-04-15
Apart from its mean value, the pulse waveform of intracranial pressure (ICP) is an essential element of pressure recording. The authors reviewed their experience with the measurement and interpretation of ICP pulse amplitude by referring to a database of recordings in hydrocephalic patients. The database contained computerized pressure recordings from 2100 infusion studies (either lumbar or intraventricular) or overnight ICP monitoring sessions in patients suffering from hydrocephalus of various types (both communicating and noncommunicating), origins, and stages of management (shunt or no shunt). Amplitude was calculated from ICP waveforms by using a spectral analysis methodology. The appearance of a pulse waveform amplitude is positive evidence of a technically correct recording of ICP and helps to distinguish between postural and vasogenic variations in ICP. Pulse amplitude is significantly correlated with the amplitude of cerebral blood flow velocity (R = 0.4, p = 0.012) as assessed using Doppler ultrasonography. Amplitude is positively correlated with a mean ICP (R = 0.21 in idiopathic normal-pressure hydrocephalus [NPH]; number of cases 131; p < 0.01) and resistance to cerebrospinal fluid outflow (R = 0.22) but does not seem to be correlated with cerebrospinal elasticity, dilation of ventricles, or severity of hydrocephalus (NPH score). Amplitude increases slightly with age (R = 0.39, p < 0.01; number of cases 46). A positive association between pulse amplitude and increased ICP during an infusion study is helpful in distinguishing between hydrocephalus and predominant brain atrophy. A large amplitude is associated with a good outcome after shunting (positive predictive power 0.9), whereas a low amplitude has no predictive power in outcome prognostication (0.5). Pulse amplitude is reduced by a properly functioning shunt. Proper recording, detection, and interpretation of ICP pulse waveforms provide clinically useful information about patients suffering from hydrocephalus.
Design and performance of heart assist or artificial heart control systems
NASA Technical Reports Server (NTRS)
Webb, J. A., Jr.; Gebben, V. D.
1978-01-01
The factors leading to the design of a controlled driving system for either a heart assist pump or artificial heart are discussed. The system provides square pressure waveform to drive a pneumatic-type blood pump. For assist usage the system uses an R-wave detector circuit that can detect the R-wave of the electrocardiogram in the presence of electrical disturbances. This circuit provides a signal useful for synchronizing an assist pump with the natural heart. It synchronizes a square wave circuit, the output of which is converted into square waveforms of pneumatic pressure suitable for driving both assist device and artificial heart. The pressure levels of the driving waveforms are controlled by means of feedback channels to maintain physiological regulation of the artificial heart's output flow. A more compact system that could achieve similar regulatory characteristics is also discussed.
Pulmonary hypertension in dogs with mitral regurgitation attributable to myxomatous valve disease.
Chiavegato, David; Borgarelli, Michele; D'Agnolo, Gino; Santilli, Roberto A
2009-01-01
Pulmonary hypertension has been associated with mitral insufficiency caused by chronic degenerative valve disease in dogs. Our aim was to search for associations between left atrial to aortic root ratio, end-systolic and end-diastolic volume indices, and changes in the right ventricular to right atrial pressure gradient as estimated by the peak velocity of tricuspid regurgitation in dogs with chronic degenerative valve disease and different classes of heart failure. Dogs, for which follow-up was available were evaluated for changes in the right ventricular to right atrial systolic pressure gradient over time. Three hundred and forty-four dogs were studied; 51 in the International Small Animal Cardiac Health Council class la, 75 in class 1b, 113 in class 2, 97 in class 3a, and 8 in class 3b. The mean values for right ventricular to right atrial systolic pressure gradient, end-systolic volume index, end-diastolic volume index, and left atrial to aortic ratio were 49.2 +/- 17.1 mmHg, 149.12 +/- 60.8 and 37.7 +/- 21.6 ml/m2, and 1.9 +/- 0.5, respectively. A weak positive correlation was found between the right ventricular to right atrial systolic pressure gradient and the left atrial to aorta ratio (r = 0.242, P < 0.0001), end-diastolic volume index (r = 0.242, P < 0.0001), and end-systolic volume index (r = 0.129, P < 0.001). Follow up was available for 49 dogs. Of these, 18 had an increased, 12 a decreased, and 19 a stable right ventricular to right atrial systolic pressure gradient despite therapy. The equivalence point between the sensitivity and specificity curves of about 80% in the coincident point corresponded to a right ventricular to right atrial systolic pressure gradient of 48 mmHg. Our results suggest an association between the progressive nature of chronic degenerative mitral valve disease and pulmonary hypertension. It is of clinical interest that, with a right ventricular to right atrial systolic pressure gradient pressure gradient at or above 48 mmHg, pulmonary hypertension does not appear to improve despite therapy targeted at lowering the left atrial load.
Nakagawa, Yoshihide; Sato, Yoji; Kojima, Takeshi; Wakabayashi, Tsutomu; Morita, Seiji; Amino, Mari; Inokuchi, Sadaki
2013-07-20
Prolonged ventricular fibrillation (VF) is associated with a low rate of return of spontaneous circulation (ROSC) following electric shock. Moreover, electric shock that does not reestablish spontaneous circulation causes myocardial dysfunction even if ROSC is subsequently achieved. Amplitude spectral area (AMSA), calculated by analysis of VF waveforms immediately before electric shock, is considered to predict the outcome of electric shock. This study aimed to evaluate the prognostic value of AMSA in relation to waveforms of defibrillators in prehospital settings. The AMSA values of 81 patients with VF confirmed by ambulance crews were compared according to the type of defibrillators with different waveforms and between those with and without ROSC. With a biphasic defibrillator, the mean AMSA was significantly different between the 14 patients who achieved ROSC (25.3 ± 9.5 mV-Hz) and the 43 subjects who did not achieve ROSC (15.4 ± 8.1 mV-Hz; p = 0.0006). No significant difference was seen in the corresponding values when a monophasic defibrillator was used, at 19.1 ± 2.4 mV-Hz for 3 ROSC patients and 16.1 ± 7.5mV-Hz for 21 non-ROSC patients. AMSA may serve as a predictive measure for ROSC following electric shock delivered by a biphasic defibrillator.
Research and Development of Advanced Life Support Equipment.
1999-02-01
kg.) were catheterized f or measurement of left ventricular pressure (LVP), right ventricular pressure (RVP), mean aortic pressure (MAP), central ...Orientation Laboratory Venous Gas Emboli Variable Profile Breathing Simulator Wingate Anaerobic Test Weapons System Trainer World Wide Web... history screening of the potential subjects was conducted to eliminate those individuals who have known health conditions/ histories which would
Canney, Michael S.; Bailey, Michael R.; Crum, Lawrence A.; Khokhlova, Vera A.; Sapozhnikov, Oleg A.
2008-01-01
Acoustic characterization of high intensity focused ultrasound (HIFU) fields is important both for the accurate prediction of ultrasound induced bioeffects in tissues and for the development of regulatory standards for clinical HIFU devices. In this paper, a method to determine HIFU field parameters at and around the focus is proposed. Nonlinear pressure waveforms were measured and modeled in water and in a tissue-mimicking gel phantom for a 2 MHz transducer with an aperture and focal length of 4.4 cm. Measurements were performed with a fiber optic probe hydrophone at intensity levels up to 24 000 W∕cm2. The inputs to a Khokhlov–Zabolotskaya–Kuznetsov-type numerical model were determined based on experimental low amplitude beam plots. Strongly asymmetric waveforms with peak positive pressures up to 80 MPa and peak negative pressures up to 15 MPa were obtained both numerically and experimentally. Numerical simulations and experimental measurements agreed well; however, when steep shocks were present in the waveform at focal intensity levels higher than 6000 W∕cm2, lower values of the peak positive pressure were observed in the measured waveforms. This underrepresentation was attributed mainly to the limited hydrophone bandwidth of 100 MHz. It is shown that a combination of measurements and modeling is necessary to enable accurate characterization of HIFU fields. PMID:19062878
Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.
Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson
2018-05-10
The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.
Ochi, H; Ikuma, I; Toda, H; Shimada, T; Morioka, S; Moriyama, K
1989-12-01
In order to determine whether isovolumic relaxation period (IRP) reflects left ventricular relaxation under different afterload conditions, 17 anesthetized, open chest dogs were studied, and the left ventricular pressure decay time constant (T) was calculated. In 12 dogs, angiotensin II and nitroprusside were administered, with the heart rate constant at 90 beats/min. Multiple linear regression analysis showed that the aortic dicrotic notch pressure (AoDNP) and T were major determinants of IRP, while left ventricular end-diastolic pressure was a minor determinant. Multiple linear regression analysis, correlating T with IRP and AoDNP, did not further improve the correlation coefficient compared with that between T and IRP. We concluded that correction of the IRP by AoDNP is not necessary to predict T from additional multiple linear regression. The effects of ascending aortic constriction or angiotensin II on IRP were examined in five dogs, after pretreatment with propranolol. Aortic constriction caused a significant decrease in IRP and T, while angiotensin II produced a significant increase in IRP and T. IRP was affected by the change of afterload. However, the IRP and T values were always altered in the same direction. These results demonstrate that IRP is substituted for T and it reflects left ventricular relaxation even in different afterload conditions. We conclude that IRP is a simple parameter easily used to evaluate left ventricular relaxation in clinical situations.
NASA Technical Reports Server (NTRS)
Webb, J. A., Jr.
1974-01-01
The multipurpose ventricular actuating system is a pneumatic signal generating device that provides controlled driving pressures for actuating pulsatile blood pumps. Overall system capabilities, the timing circuitry, and calibration instruction are included.
Samadov, Fuad; Yesildag, Osman; Sari, Ibrahim; Atas, Halil; Akhundova, Aysel; Basaran, Yelda
2017-06-01
Although numerous studies have shown the protective effects of the well-developed coronary collaterals on left ventricular functions, the relationship between collateral grade and left ventricular end diastolic pressure has not been studied in chronic total occlusion patients. Also, there are conflicting data on the effect of collaterals on NT-proBNP levels. The aim of our study was to evaluate the relationship between coronary collateral circulation and left ventricular end diastolic pressure and NT-proBNP levels in chronic total occlusion patients. Study group was retrospectively selected from the patients who had undergone coronary angiography at our hospital between June 2011 and March 2013. Clinical, biochemical, angiographic and hemodynamic data of 199 consecutive patients having at least one totally occluded major epicardial coronary artery were evaluated. Coronary collateral circulation was graded according to Rentrop classification. While Rentrop grade 3 was defined as well-developed, all the remaining collateral grades were regarded as poor collaterals. Overall 87 patients were found to have good collaterals and 112 patients had poor collaterals. There was no significant difference between the patients with well- or poorly developed coronary collaterals with regard to left ventricular end diastolic pressure (16.84 ± 5.40 mmHg vs 16.10 ± 6.09, respectively, p = 0,632) and log NT-proBNP (2.46 ± 0.58 vs 2.59 ± 0.76, respectively, p = 0,335). In patients with coronary chronic total occlusion even well-developed coronary collaterals are not capable of protecting the rise of left ventricular end diastolic pressure and NT-proBNP levels which are reliable markers of the left ventricular dysfunction.
Some effects of oscillation waveform and amplitude on unsteady turbulent shear flows
NASA Technical Reports Server (NTRS)
Agarwal, Naval K.; Simpson, Roger L.; Shivaprasad, B. G.
1992-01-01
Some physical features of several unsteady separating turbulent boundary layers are presented for practical Reynolds numbers and reduced frequencies such as for helicopter and turbomachinery flows. The effects of unsteadiness amplitude and waveform are examined for flows along the floor of a converging and diverging wind tunnel test section. At the end of the converging portion, the mean skin friction coefficient normalized on the mean dynamic pressure is independent of the waveform and amplitude within low experimental uncertainties. In the detaching and detached portions of the flow, wall values of the fraction of time that the flow moves downstream of gamma sub pu, which is a separated flow state variable, shows that oscillation waveform and amplitude strongly influence the detached flow behavior. Distributions of gamma sub pu during a cycle indicate hysteresis within the detached flow and the effects of the higher harmonics of pressure gradient and velocity.
Kim, Mi Ok; O'Rourke, Michael F; Adji, Audrey; Avolio, Alberto P
2016-01-01
In the time domain, pulsatile flow and pressure can be characterised as the ratio of the late systolic boost of flow or pressure to the pulse amplitude so as to estimate the hydraulic input to the brain. While vascular impedance has been widely used to represent the load presented to the heart by the systemic circulation, it has not been applied to the cerebral circulation.We set out to study the relationship between the pressure and the flow augmentation index (AIx) in the time domain and to determine cerebral vascular impedance using aortic blood pressure and cerebral blood flow waveforms in the frequency domain. Twenty-four young subjects (aged 21-39 years) were recruited; aortic pressure was derived using SphygmoCor from radial pressure. Flow waveforms were recorded from the middle cerebral artery. In three subjects, we performed the Valsalva manoeuvre to investigate their response to physiological intervention. There was a linear relationship between flow and pressure AIx, and cerebral impedance values were similar to those estimated for low resistance vascular beds. Substantial change in pressure and flow wave contour was observed during the Valsalva manoeuvre; however, the relationship in both the time and the frequency domains were unchanged. This confirms that aortic pressure and cerebral flow waveform can be used to study cerebral impedance.
Inhibition of coronary blood flow by a vascular waterfall mechanism.
Downey, J M; Kirk, E S
1975-06-01
The mechanism whereby systole inhibits coronary blood flow was examined. A branch of the left coronary artery was maximally dilated with an adenosine infusion, and the pressure-flow relationship was obtained for beating and arrested states. The pressure-flow curve for the arrested state was shifted toward higher pressures and in the range of pressures above peak ventricular pressure was linear and parallel to that for the arrested state. Below this range the curve for the beating state converged toward that for the arrested state and was convex to the pressure axis. These results were compared with a model of the coronary vasculature that consisted of numerous parallel channels, each responding to local intramyocardial pressure by forming vascular waterfalls. When intramyocardial pressure in the model was assigned values from zero at the epicardium to peak ventricular pressure at the endocardium, pressure-flow curves similar to the experimental ones resulted. Thus, we conclude that systole inhibits coronary perfusion by the formation of vascular waterfalls and that the intramyocardial pressures responsible for this inhibition do not significantly exceed peak ventricular pressure.
Facchin, L.; Vescovo, G.; Levedianos, G.; Zannini, L.; Nordio, M.; Lorenzi, S.; Caturelli, G.; Ambrosio, G. B.
1995-01-01
OBJECTIVE--To see whether cardiac morphological and functional abnormalities in uraemic patients are determined by high blood pressure or if they are an expression of a specific cardiomyopathy. DESIGN--Cross sectional study. SETTING--City general hospital in Italy. SUBJECTS--35 uraemic patients receiving haemodialysis (17 men, 18 women; mean age 60.3 (11.2); mean duration of dialysis 52 months) were selected from the 64 patients in Venice who were receiving dialysis; subjects with diabetes, haemochromatosis, valvar dysfunction, regional dyskinesias, and pericarditis were excluded. 19 control normotensive subjects (6 men and 13 women), matched for age. MAIN OUTCOME MEASURES--Echocardiographic measurements of left atrium, left ventricular end diastolic and end systolic volume, aortic root diameter, posterior wall and interventricular septum thickness, left ventricle mass index, and ejection fraction in controls and in patients according to whether they were normotensive (five men, eight women) or hypertensive (12 men, 10 women) on 48 hour ambulatory monitoring; left ventricular diastolic function by Doppler ultrasonography. RESULTS--Mean systolic and diastolic pressures, daytime systolic and diastolic pressures, and night time systolic and diastolic pressures were significantly higher in the hypertensive patients than in the normotensive patients. The normotensive patients had similar blood pressures to the controls. Left ventricular mass correlated significantly with the mean diastolic pressure and mean night time systolic and diastolic pressures. Parathyroid hormone concentrations were similar in the two groups of patients. Diastolic relaxation was impaired to the same degree in the two groups of patients. Parameters of diastolic function showed no relation to left ventricular mass, which was significantly higher in the hypertensive than in the normotensive patients. CONCLUSIONS--Uraemia is likely to induce specific changes in the relaxation properties of the myocardium. These changes are responsible for the impaired diastolic function independently of blood pressure, degree of hypertrophy, and metabolic changes, which suggests the existence of a specific cardiomyopathy. Hypertension remains a determinant of left ventricular mass. PMID:7546998
Magalski, Anthony; Adamson, Philip; Gadler, Frederick; Böehm, Michael; Steinhaus, David; Reynolds, Dwight; Vlach, Kathryn; Linde, Cecilia; Cremers, Bodo; Sparks, Brandon; Bennett, Tom
2002-04-01
We describe the performance of an implantable hemodynamic monitor (IHM) that allows continuous recording of heart rate, patient activity levels, and right ventricular systolic, right ventricular diastolic, and estimated pulmonary artery diastolic pressures. Pressure parameters derived from the implantable monitor were correlated to measurements made with a balloon-tipped catheter to establish accuracy and reproducibility over time in patients with chronic heart failure (CHF). IHM devices were implanted in 32 patients with CHF (left ventricular ejection fraction, 29% +/- 11%; range, 14%-62%) and were tested with right heart catheterization at implantation and 3, 6, and 12 months later. Hemodynamic variables were digitally recorded simultaneously from the IHM and catheter. Values were recorded during supine rest, peak response of Valsalva maneuver, sitting, peak of a 2-stage (25-50 W) bicycle exercise test, and final rest period. The median of 21 paired beat-to-beat cardiac cycles was analyzed for each intervention. A total of 217 paired data values from all maneuvers were analyzed for 32 patients at implantation and 129 paired data values for 20 patients at 1 year. The IHM and catheter values were not different at baseline or at 1 year (P >.05). Combining all interventions, correlation coefficients were 0.96 and 0.94 for right ventricular systolic pressure, 0.96 and 0.83 for right ventricular diastolic pressure, and 0.87 and 0.87 for estimated pulmonary artery diastolic pressure at implantation and 1 year, respectively. The IHM and a standard reference pressure system recorded comparable right heart pressure values in patients with CHF. This implantable pressure transducer is accurate over time and provides a means to precisely monitor the hemodynamic condition of patients with CHF in a continuous fashion.
Evolution of the optimum bidirectional (+/- biphasic) wave for defibrillation.
Geddes, L A; Havel, W
2000-01-01
Introduction of the asymmetric bidirectional (+/- biphasic) current waveform has made it possible to achieve ventricular defibrillation with less energy and current than are needed with a unidirectional (monophasic) waveform. The symmetrical bidirectional (sinusoidal) waveform was used for the first human-heart defibrillation. Subsequent studies employed the underdamped and overdamped sine waves, then the trapezoidal (monophasic) wave. Studies were then undertaken to investigate the benefit of adding a second identical and inverted wave; little success rewarded these efforts until it was discovered that the second inverted wave needed to be much less in amplitude to lower the threshold for defibrillation. However, there is no physiologic theory that explains the mechanism of action of the bidirectional wave, nor does any theory predict the optimum amplitude and time dimensions for the second inverted wave. The authors analyze the research that shows that the threshold defibrillation energy is lowest when the charge in the second, inverted phase is slightly more than a third of that in the first phase. An ion-flux, spatial-K+ summation hypothesis is presented that shows the effect on myocardial cells of adding the second inverted current pulse.
PLATELET ADHESION TO POLYURETHANE UREA UNDER PULSATILE FLOW CONDITIONS
Navitsky, Michael A.; Taylor, Joshua O.; Smith, Alexander B.; Slattery, Margaret J.; Deutsch, Steven; Siedlecki, Christopher A.; Manning, Keefe B.
2014-01-01
Platelet adhesion to a polyurethane urea surface is a precursor to thrombus formation within blood-contacting cardiovascular devices, and platelets have been found to adhere strongly to polyurethane surfaces below a shear rate of approximately 500 s−1. The aim of the current work is to determine platelet adhesion properties to the polyurethane urea surface as a function of time varying shear exposure. A rotating disk system is used to study the influence of steady and pulsatile flow conditions (e.g. cardiac inflow and sawtooth waveforms) for platelet adhesion to the biomaterial surface. All experiments retain the same root mean square angular rotation velocity (29.63 rad/s) and waveform period. The disk is rotated in platelet rich bovine plasma for two hours with adhesion quantified by confocal microscopy measurements of immunofluorescently labeled bovine platelets. Platelet adhesion under pulsating flow is found to exponentially decay with increasing shear rate. Adhesion levels are found to depend upon peak platelet flux and shear rate regardless of rotational waveform. In combination with flow measurements, these results may be useful for predicting regions susceptible to thrombus formation within ventricular assist devices. PMID:24721222
NASA Technical Reports Server (NTRS)
Koenig, S. C.; Ludwig, D. A.; Reister, C.; Fanton, J. W.; Ewert, D.; Convertino, V. A.
2001-01-01
Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.
Markus, Marcello Ricardo Paulista; Stritzke, Jan; Lieb, Wolfgang; Mayer, Björn; Luchner, Andreas; Döring, Angela; Keil, Ulrich; Hense, Hans-Werner; Schunkert, Heribert
2008-10-01
It is unclear whether persistent prehypertension causes structural or functional alterations of the heart. We examined echocardiographic data of 1005 adults from a population-based survey at baseline in 1994/1995 and at follow-up in 2004/2005. We compared individuals who had either persistently normal (<120 mmHg systolic and <80 mmHg diastolic, n = 142) or prehypertensive blood pressure (120-139 mmHg or 80-89 mmHg, n = 119) at both examinations using multivariate regression modeling. Over 10 years, left ventricular end-diastolic diameters were stable and did not differ between the two groups. However, the prehypertensive blood pressure group displayed more pronounced ageing-related increases of left ventricular wall thickness (+4.7 versus +11.9%, P < 0.001) and left ventricular mass (+8.6 versus +15.7%, P = 0.006). Prehypertension was associated with a raised incidence of left ventricular concentric remodeling (adjusted odds ratio 10.7, 95% confidence interval 2.82-40.4) and left ventricular hypertrophy (adjusted odds ratio 5.33, 1.58-17.9). The ratio of early and late diastolic peak transmitral flow velocities (E/A) decreased by 7.7% in the normal blood pressure versus 15.7% in the prehypertensive blood pressure group (P = 0.003) and at follow-up the ratio of early diastolic peak transmitral flow and early diastolic peak myocardial relaxation velocities (E/EM) was higher (9.1 versus 8.5, P = 0.031) and left atrial size was larger (36.5 versus 35.3 mm, P = 0.024) in the prehypertensive blood pressure group. Finally, the adjusted odds ratio for incident diastolic dysfunction was 2.52 (1.01-6.31) for the prehypertensive blood pressure group. Persistent prehypertension accelerates the development of hypertrophy and diastolic dysfunction of the heart.
Wooldridge, Anne A; Eades, Susan C; Hosgood, Giselle L; Moore, Rustin M
2002-12-01
To compare effects of oxytocin, acepromazine maleate, xylazine hydrochloride-butorphanol tartrate, guaifenesin, and detomidine hydrochloride on esophageal manometric pressure in horses. 8 healthy adult horses. A nasogastric tube, modified with 3 polyethylene tubes that exited at the postpharyngeal area, thoracic inlet, and distal portion of the esophagus, was fitted for each horse. Amplitude, duration, and rate of propagation of pressure waveforms induced by swallows were measured at 5, 10, 20, 30, and 40 minutes after administration of oxytocin, detomidine, acepromazine, xylazine-butorphanol, guaifenesin, or saline (0.9% NaCI) solution. Number of spontaneous swallows, spontaneous events (contractions that occurred in the absence of a swallow stimulus), and high-pressure events (sustained increases in baseline pressure of > 10 mm Hg) were compared before and after drug adminision. At 5 minutes after administration, detomidine increased waveform amplitude and decreased waveform duration at the thoracic inlet. At 10 minutes after administration, detomidine increased waveform duration at the thoracic inlet. Acepromazine administration increased the number of spontaneous events at the thoracic inlet and distal portion of the esophagus. Acepromazine and detomidine administration increased the number of high-pressure events at the thoracic inlet. Guaifenesin administration increased the number of spontaneous events at the thoracic inlet. Xylazine-butorphanol, detomidine, acepromazine, and guaifenesin administration decreased the number of spontaneous swallows. Detomidine, acepromazine, and a combination of xylazine butorphanol had the greatest effect on esophageal motility when evaluated manometrically. Reduction in spontaneous swallowing and changes in normal, coordinated peristaltic activity are the most clinically relevant effects.
Gan, Rong Z; Nakmali, Don; Ji, Xiao D; Leckness, Kegan; Yokell, Zachary
2016-10-01
Mechanical damage to middle ear components in blast exposure directly causes hearing loss, and the rupture of the tympanic membrane (TM) is the most frequent injury of the ear. However, it is unclear how the severity of injury graded by different patterns of TM rupture is related to the overpressure waveforms induced by blast waves. In the present study, the relationship between the TM rupture threshold and the impulse or overpressure waveform has been investigated in chinchillas. Two groups of animals were exposed to blast overpressure simulated in our lab under two conditions: open field and shielded with a stainless steel cup covering the animal head. Auditory brainstem response (ABR) and wideband tympanometry were measured before and after exposure to check the hearing threshold and middle ear function. Results show that waveforms recorded in the shielded case were different from those in the open field and the TM rupture threshold in the shielded case was lower than that in the open field (3.4 ± 0.7 vs. 9.1 ± 1.7 psi or 181 ± 1.6 vs. 190 ± 1.9 dB SPL). The impulse pressure energy spectra analysis of waveforms demonstrates that the shielded waveforms include greater energy at high frequencies than that of the open field waves. Finally, a 3D finite element (FE) model of the chinchilla ear was used to compute the distributions of stress in the TM and the TM displacement with impulse pressure waves. The FE model-derived change of stress in response to pressure loading in the shielded case was substantially faster than that in the open case. This finding provides the biomechanical mechanisms for blast induced TM damage in relation to overpressure waveforms. The TM rupture threshold difference between the open and shielded cases suggests that an acoustic role of helmets may exist, intensifying ear injury during blast exposure. Copyright © 2016 Elsevier B.V. All rights reserved.
Tomiyama, Hirofumi; Nishikimi, Toshio; Matsumoto, Chisa; Kimura, Kazutaka; Odaira, Mari; Shiina, Kazuki; Yamashina, Akira
2015-04-01
We determined whether any significant association exists between change in late systolic cardiac load with time, estimated by radial pressure waveform analysis, and development of cardiac hemodynamic stress in individuals with preserved cardiac function. Brachial-ankle pulse wave velocity, radial augmentation index (rAI), first peak of the radial pressure waveform (SP1), systolic and pulse pressure at the second peak of the radial pressure waveform (SP2 and PP2), and serum levels of N-terminal fragment B-type natriuretic peptide (NT-proBNP) were measured at the start (first examination) and at the end (second examination) of this 3-year study in healthy Japanese men (n = 1,851). A stepwise multivariate linear regression analysis demonstrated that among the parameters of radial pressure waveform analysis and markers of arterial stiffness analyzed, only PP2 was significantly associated with serum NT-proBNP levels in study participants at both the first and second examinations. Furthermore, among the parameters analyzed, only change in PP2 was significantly correlated with the change in serum NT-proBNP levels during the study period (beta = 0.131, P < 0.001). Sustained late systolic cardiac load might be a more significant determinant of the development of cardiac hemodynamic stress than sustained early systolic cardiac load or arterial stiffening in individuals with preserved cardiac function. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Driessen, Mieke M P; Hui, Wei; Bijnens, Bart H; Dragulescu, Andreea; Mertens, Luc; Meijboom, Folkert J; Friedberg, Mark K
2016-06-01
Right ventricular (RV) pressure overload has a vastly different clinical course in children with idiopathic pulmonary arterial hypertension (iPAH) than in children with pulmonary stenosis (PS). While RV function is well recognized as a key prognostic factor in iPAH, adverse ventricular-ventricular interactions and LV dysfunction are less well characterized and the pathophysiology is incompletely understood. We compared ventricular-ventricular interactions as hypothesized drivers of biventricular dysfunction in pediatric iPAH versus PS Eighteen iPAH, 16 PS patients and 18 age- and size-matched controls were retrospectively studied. Cardiac cycle events were measured by M-mode and Doppler echocardiography. Measurements were compared between groups using ANOVA with post hoc Dunnet's or ANCOVA including RV systolic pressure (RVSP; iPAH 96.8 ± 25.4 mmHg vs. PS 75.4 ± 18.9 mmHg; P = 0.011) as a covariate. RV-free wall thickening was prolonged in iPAH versus PS, extending beyond pulmonary valve closure (638 ± 76 msec vs. 562 ± 76 msec vs. 473 ± 59 msec controls). LV and RV isovolumetric relaxation were prolonged in iPAH (P < 0.001; LV 102.8 ± 24.1 msec vs. 63.1 ± 13.7 msec; RV 95 [61-165] vs. 28 [0-43]), associated with adverse septal kinetics; characterized by rightward displacement in early systole and leftward displacement in late RV systole (i.e., early LV diastole). Early LV diastolic filling was decreased in iPAH (73 ± 15.9 vs. PS 87.4 ± 14.4 vs. controls 95.8 ± 12.5 cm/sec; P = 0.004). Prolonged RVFW thickening, prolonged RVFW isovolumetric times, and profound septal dyskinesia are associated with interventricular mechanical discoordination and decreased early LV filling in pediatric iPAH much more than PS These adverse mechanics affect systolic and diastolic biventricular efficiency in iPAH and may form the basis for worse clinical outcomes. We used clinically derived data to study the pathophysiology of ventricular-ventricular interactions in right ventricular pressure overload, demonstrating distinct differences between pediatric pulmonary arterial hypertension (iPAH) and pulmonary stenosis (PS). Altered timing of right ventricular free wall contraction and profound septal dyskinesia are associated with interventricular mechanical discoordination and decreased early LV filling in iPAH much more than PS These adverse mechanics affect systolic and diastolic biventricular efficiency, independent of right ventricular systolic pressure. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.
Modeling of an electrohydraulic lithotripter with the KZK equation.
Averkiou, M A; Cleveland, R O
1999-07-01
The acoustic pressure field of an electrohydraulic extracorporeal shock wave lithotripter is modeled with a nonlinear parabolic wave equation (the KZK equation). The model accounts for diffraction, nonlinearity, and thermoviscous absorption. A numerical algorithm for solving the KZK equation in the time domain is used to model sound propagation from the mouth of the ellipsoidal reflector of the lithotripter. Propagation within the reflector is modeled with geometrical acoustics. It is shown that nonlinear distortion within the ellipsoidal reflector can play an important role for certain parameters. Calculated waveforms are compared with waveforms measured in a clinical lithotripter and good agreement is found. It is shown that the spatial location of the maximum negative pressure occurs pre-focally which suggests that the strongest cavitation activity will also be in front of the focus. Propagation of shock waves from a lithotripter with a pressure release reflector is considered and because of nonlinear propagation the focal waveform is not the inverse of the rigid reflector. Results from propagation through tissue are presented; waveforms are similar to those predicted in water except that the higher absorption in the tissue decreases the peak amplitude and lengthens the rise time of the shock.
[The research in a foot pressure measuring system based on LabVIEW].
Li, Wei; Qiu, Hong; Xu, Jiang; He, Jiping
2011-01-01
This paper presents a system of foot pressure measuring system based on LabVIEW. The designs of hardware and software system are figured out. LabVIEW is used to design the application interface for displaying plantar pressure. The system can realize the plantar pressure data acquisition, data storage, waveform display, and waveform playback. It was also shown that the testing results of the system were in line with the changing trend of normal gait, which conformed to human system engineering theory. It leads to the demonstration of system reliability. The system gives vivid and visual results, and provides a new method of how to measure foot-pressure and some references for the design of Insole System.
Maggi, Roberto; Viscardi, Valentina; Furukawa, Toshiyuki; Brignole, Michele
2010-11-01
We thought to evaluate feasibility of continuous non-invasive blood pressure monitoring during procedures of interventional electrophysiology. We evaluated continuous non-invasive finger blood pressure (BP) monitoring by means of the Nexfin device in 22 patients (mean age 70 ± 24 years), undergoing procedures of interventional electrophysiology, in critical situations of hypotension caused by tachyarrhythmias or by intermittent incremental ventricular temporary pacing till to the maximum tolerated systolic BP fall (mean 61 ± 14 mmHg per patient at a rate of 195 ± 37 bpm). In all patients, Nexfin was able to detect immediately, at the onset of tachyarrythmia, the changes in BP and recorded reliable waveforms. The quality of the signal was arbitrarily classified as excellent in 11 cases, good in 10 cases, and sufficient in 1 case. In basal conditions, calibrations of the signal occurred every 49.2 ± 24.3 s and accounted for 4% of total monitoring time; during tachyarrhythmias their frequency increased to one every 12.7 s and accounted for 19% of total recording duration. A linear correlation for a range of BP values from 41 to 190 mmHg was found between non-invasive and intra-arterial BP among a total of 1055 beats from three patients who underwent simultaneous recordings with both methods (coefficient of correlation of 0.81, P < 0.0001). In conclusion, continuous non-invasive BP monitoring is feasible in the clinical practise of an interventional electrophysiology laboratory without the need of utilization of an intra-arterial BP line.
Berg, Robert A; Sorrell, Vincent L; Kern, Karl B; Hilwig, Ronald W; Altbach, Maria I; Hayes, Melinda M; Bates, Kathryn A; Ewy, Gordon A
2005-03-08
Most out-of-hospital ventricular fibrillation (VF) is prolonged (>5 minutes), and defibrillation from prolonged VF typically results in asystole or pulseless electrical activity. Recent visual epicardial observations in an open-chest, open-pericardium model of swine VF indicate that blood flows from the high-pressure arterial system to the lower-pressure venous system during untreated VF, thereby overdistending the right ventricle and apparently decreasing left ventricular size. Therefore, inadequate left ventricular stroke volume after defibrillation from prolonged VF has been postulated as a major contributor to the development of pulseless rhythms. Ventricular dimensions were determined by MRI for 30 minutes of untreated VF in a closed-chest, closed-pericardium model in 6 swine. Within 1 minute of untreated VF, mean right ventricular volume increased by 29% but did not increase thereafter. During the first 5 minutes of untreated VF, mean left ventricular volume increased by 34%. Between 20 and 30 minutes of VF, stone heart occurred as manifested by dramatic thickening of the myocardium and concomitant substantial decreases in left ventricular volume. In this closed-chest swine model of VF, substantial right ventricular volume changes occurred early and did not result in smaller left ventricular volumes. The changes in ventricular volumes before the late development of stone heart do not explain why defibrillation from brief duration VF (<5 minutes) typically results in a pulsatile rhythm with return of spontaneous circulation, whereas defibrillation from prolonged VF (5 to 15 minutes) does not.
Ghosh, Justin; Singarayar, Suresh; Kabunga, Peter; McGuire, Mark A
2015-06-01
The phrenic nerves may be damaged during catheter ablation of atrial fibrillation. Phrenic nerve function is routinely monitored during ablation by stimulating the right phrenic nerve from a site in the superior vena cava (SVC) and manually assessing the strength of diaphragmatic contraction. However the optimal stimulation site, method of assessing diaphragmatic contraction, and techniques for monitoring the left phrenic nerve have not been established. We assessed novel techniques to monitor phrenic nerve function during cryoablation procedures. Pacing threshold and stability of phrenic nerve capture were assessed when pacing from the SVC, left and right subclavian veins. Femoral venous pressure waveforms were used to monitor the strength of diaphragmatic contraction. Stable capture of the left phrenic nerve by stimulation in the left subclavian vein was achieved in 96 of 100 patients, with a median capture threshold of 2.5 mA [inter-quartile range (IQR) 1.4-5.0 mA]. Stimulation of the right phrenic nerve from the subclavian vein was superior to stimulation from the SVC with lower pacing thresholds (1.8 mA IQR 1.4-3.3 vs. 6.0 mA IQR 3.4-8.0, P < 0.001). Venous pressure waveforms were obtained in all patients and attenuation of the waveform was always observed prior to onset of phrenic nerve palsy. The left phrenic nerve can be stimulated from the left subclavian vein. The subclavian veins are the optimal sites for phrenic nerve stimulation. Monitoring the femoral venous pressure waveform is a novel technique for detecting impending phrenic nerve damage. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Hope, Sarah A; Antonis, Paul; Adam, David; Cameron, James D; Meredith, Ian T
2007-10-01
The aim of this study was to test the hypothesis that coronary artery disease extent and severity are associated with central aortic pressure waveform characteristics. Although it is thought that central aortic pressure waveform characteristics, particularly augmentation index, may influence cardiovascular disease progression and predict cardiovascular risk, little is known of the relationship between central waveform characteristics and the severity and extent of coronary artery disease. Central aortic waveforms (2F Millar pressure transducer-tipped catheters) were acquired at the time of coronary angiography for suspected native coronary artery disease in 40 patients (24 male). The severity and extent of disease were assessed independently by two observers using two previously described scoring systems (modified Gensini's stenosis and Sullivan's extent scores). Relationships between disease scores, aortic waveform characteristics, aorto-radial pulse wave velocity and subject demographic features were assessed by regression techniques. Both extent and severity scores were associated with increasing age and male sex (P < 0.001), but no other risk factors. Both scores were independently associated with aorto-radial pulse wave velocity (P < 0.001), which entered a multiple regression model prior to age and sex. This association was not dependent upon blood pressure. Neither score was associated with central aortic augmentation index, by either simple or multiple linear regression techniques including heart rate, subject demographic features and cardiovascular risk factors. Aorto-radial pulse wave velocity, but not central aortic augmentation index, is associated with both the extent and severity of coronary artery disease. This has potentially important implications for applicability of a generalized arterial transfer function.
Experimental myocardial infarction
Kumar, Raj; Joison, Julio; Gilmour, David P.; Molokhia, Farouk A.; Pegg, C. A. S.; Hood, William B.
1971-01-01
The hemodynamic effects of tachycardia induced by atrial pacing were investigated in left ventricular failure of acute and healing experimental myocardial infarction in 20 intact, conscious dogs. Myocardial infarction was produced by gradual inflation of a balloon cuff device implanted around the left anterior descending coronary artery 10-15 days prior to the study. 1 hr after acute myocardial infarction, atrial pacing at a rate of 180 beats/min decreased left ventricular end-diastolic pressure from 19 to 8 mm Hg and left atrial pressure from 17 to 12 mm Hg, without change in cardiac output. In the healing phase of myocardial infarction 1 wk later, atrial pacing decreased left ventricular end-diastolic pressure from 17 to 9 mm Hg and increased the cardiac output by 37%. This was accompanied by evidence of peripheral vasodilation. In two dogs with healing anterior wall myocardial infarction, left ventricular failure was enhanced by partial occlusion of the circumflex coronary artery. Both the dogs developed pulmonary edema. Pacing improved left ventricular performance and relieved pulmonary edema in both animals. In six animals propranolol was given after acute infarction, and left ventricular function deteriorated further. However the pacing-induced augmentation of cardiac function was unaltered and, hence, is not mediated by sympathetics. The results show that the spontaneous heart rate in left ventricular failure of experimental canine myocardial infarction may be less than optimal and that maximal cardiac function may be achieved at higher heart rates. Images PMID:4395910
Sveälv, Bente Grüner; Täng, Margareta Scharin; Cider, Åsa
2012-01-01
Hydrotherapy (exercise in warm water) is considered to be a safe and beneficial method to use in the rehabilitation of stable heart failure patients, but there is little information on the effect of the increased venous return and enhanced preload in elderly patients with biventricular heart failure. We present a case of an elderly man who was recruited to participate in a hydrotherapy study. We compared echocardiographic data during warm water immersion with land measurements, and observed increases in stroke volume from 32 mL (land) to 42 mL (water), left ventricular ejection fraction from 22% to 24%, left ventricular systolic velocity from 4.8 cm/s to 5.0 cm/s and left atrioventricular plane displacement from 2.1 mm to 2.2 mm. By contrast, right ventricular systolic velocity decreased from 11.2 cm/s to 8.4 cm/s and right atrioventricular plane displacement from 8.1 mm to 4.7 mm. The tricuspid pressure gradient rose from 18 mmHg on land to 50 mmHg during warm water immersion. Thus, although left ventricular systolic function was relatively unaffected during warm water immersion, we observed a decrease in right ventricular function with an augmented right ventricular pressure. We recommend further investigations to observe the cardiac effect of warm water immersion on patients with biventricular systolic heart failure and at risk of elevated right ventricular pressure. PMID:23341846
Atmospheric pressure ion focusing in a high-field asymmetric waveform ion mobility spectrometer
NASA Astrophysics Data System (ADS)
Guevremont, Roger; Purves, Randy W.
1999-02-01
The focusing of ions at atmospheric pressure and room temperature in a high-field asymmetric waveform ion mobility spectrometer (FAIMS) has been investigated. FAIMS operates with the application of a high-voltage, high-frequency asymmetric waveform across parallel plates. This establishes conditions wherein an ion migrates towards one of the plates because of a difference in the ion mobility at the low and high electric field conditions during application of the waveform. The migration can be stopped by applying a dc compensation voltage (CV) which serves to create a "balanced" condition wherein the ion experiences no net transverse motion. This method has also been called "transverse field compensation ion mobility spectrometry" and "field ion spectrometry®." If this experiment is conducted using a device with cylindrical geometry, rather than with flat plates, an ion focusing region can exist in the annular space between the two concentric cylinders. Ion trajectory modeling showed that the behavior of the ions in the cylindrical geometry FAIMS analyzer was unlike any previously described atmospheric pressure ion optics system. The ions appeared to be trapped, or focused by being caught between two opposing forces. Requirements for establishing this focus for a given ion were identified: the applied waveform must be asymmetric, the electric field must be sufficiently high that the mobility of the ion deviates from its low-field value during the high-voltage portion of the asymmetric waveform, and finally, the electric field must be nonuniform in space (e.g., cylindrical or spherical geometry). Experimental observations with a prototype FAIMS device, which was designed to measure the radial distribution of ions in the FAIMS analyzer region, have confirmed the results of ion trajectory modeling.
NASA Astrophysics Data System (ADS)
Chang, Jiaqing; Liu, Yaxin; Huang, Bo
2017-07-01
In inkjet applications, it is normal to search for an optimal drive waveform when dispensing a fresh fluid or adjusting a newly fabricated print-head. To test trial waveforms with different dwell times, a camera and a strobe light were used to image the protruding or retracting liquid tongues without ejecting any droplets. An edge detection method was used to calculate the lengths of the liquid tongues to draw the meniscus movement curves. The meniscus movement is determined by the time-domain response of the acoustic pressure at the nozzle of the print-head. Starting at the inverse piezoelectric effect, a mathematical model which considers the liquid viscosity in acoustic propagation is constructed to study the acoustic pressure response at the nozzle of the print-head. The liquid viscosity retards the propagation speed and dampens the harmonic amplitude. The pressure response, which is the combined effect of the acoustic pressures generated during the rising time and the falling time and after their propagations and reflections, explains the meniscus movements well. Finally, the optimal dwell time for droplet ejections is discussed.
Dekker, A L A J; Phelps, B; Dijkman, B; van der Nagel, T; van der Veen, F H; Geskes, G G; Maessen, J G
2004-06-01
Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.
Shehab, Sajad; Allida, Sabine M; Davidson, Patricia M; Newton, Phillip J; Robson, Desiree; Jansz, Paul C; Hayward, Christopher S
Right ventricular failure after left ventricular assist device (LVAD) implantation is associated with high mortality. Management remains limited to pharmacologic therapy and temporary mechanical support. Delayed right ventricular assist device (RVAD) support after LVAD implantation is associated with poorer outcomes. With the advent of miniaturized, durable, continuous flow ventricular assist device systems, chronic RVAD and biventricular assist device (BiVAD) support has been used with some success. The purpose of this study was to assess combined BiVAD and LVAD with delayed RVAD support within a four-elemental mock circulatory loop (MCL) simulating the human cardiovascular system. Our hypothesis was that delayed continuous flow RVAD (RVAD) would produce similar hemodynamic and flow parameters to those of initial BiVAD support. Using the MCL, baseline biventricular heart failure with elevated right and left filling pressures with low cardiac output was simulated. The addition of LVAD within a biventricular configuration improved cardiac output somewhat, but was associated with persistent right heart failure with elevated right-sided filling pressures. The addition of an RVAD significantly improved LVAD outputs and returned filling pressures to normal throughout the circulation. In conclusion, RVAD support successfully restored hemodynamics and flow parameters of biventricular failure supported with isolated LVAD with persistent elevated right atrial pressure.
Georgoulis, George; Papagrigoriou, Eirini; Sindou, Marc
2015-12-01
A crucial aspect of surgery on the supraclavicular region, lateral neck, and mid-cervical vertebral region is the identification and sparing of the phrenic nerve and cervical (C4) root that are responsible for diaphragmatic innervation. Therefore intraoperative mapping of these nerve structures can be useful for difficult cases. Electrical stimulation with simultaneous observation of the ventilator waveforms of the anesthesia machine provides an effective method for the precise intraoperative mapping of these structures. In the literature, there is only one publication reporting the use of one of the waveforms (capnography) for this purpose. Capnography and pressure-time waveforms, two mandatory curves in anesthesiological monitoring, were studied under electrical stimulation of the phrenic nerve (one patient) and the C4 root (eight patients). The aim was to detect changes that would verify diaphragmatic contraction. No modifications in anesthesia or surgery and no additional maneuvers were required. In all patients, stimulation was followed by identifiable changes in the two waveforms, compatible with diaphragmatic contraction: acute reduction in amplitude on capnography and repetitive saw-like elevations on pressure-time curve. Frequency of patterns on pressure-time curve coincided with the frequency of stimulation; therefore the two recordings were complementary. This simple method proved effective in identifying the neural structures responsible for diaphragmatic function. We therefore suggest that it should be employed in the various types of surgery where these structures are at risk.
Right Ventricular Perfusion: Physiology and Clinical Implications.
Crystal, George J; Pagel, Paul S
2018-01-01
Regulation of blood flow to the right ventricle differs significantly from that to the left ventricle. The right ventricle develops a lower systolic pressure than the left ventricle, resulting in reduced extravascular compressive forces and myocardial oxygen demand. Right ventricular perfusion has eight major characteristics that distinguish it from left ventricular perfusion: (1) appreciable perfusion throughout the entire cardiac cycle; (2) reduced myocardial oxygen uptake, blood flow, and oxygen extraction; (3) an oxygen extraction reserve that can be recruited to at least partially offset a reduction in coronary blood flow; (4) less effective pressure-flow autoregulation; (5) the ability to downregulate its metabolic demand during coronary hypoperfusion and thereby maintain contractile function and energy stores; (6) a transmurally uniform reduction in myocardial perfusion in the presence of a hemodynamically significant epicardial coronary stenosis; (7) extensive collateral connections from the left coronary circulation; and (8) possible retrograde perfusion from the right ventricular cavity through the Thebesian veins. These differences promote the maintenance of right ventricular oxygen supply-demand balance and provide relative resistance to ischemia-induced contractile dysfunction and infarction, but they may be compromised during acute or chronic increases in right ventricle afterload resulting from pulmonary arterial hypertension. Contractile function of the thin-walled right ventricle is exquisitely sensitive to afterload. Acute increases in pulmonary arterial pressure reduce right ventricular stroke volume and, if sufficiently large and prolonged, result in right ventricular failure. Right ventricular ischemia plays a prominent role in these effects. The risk of right ventricular ischemia is also heightened during chronic elevations in right ventricular afterload because microvascular growth fails to match myocyte hypertrophy and because microvascular dysfunction is present. The right coronary circulation is more sensitive than the left to α-adrenergic-mediated constriction, which may contribute to its greater propensity for coronary vasospasm. This characteristic of the right coronary circulation may increase its vulnerability to coronary vasoconstriction and impaired right ventricular perfusion during administration of α-adrenergic receptor agonists.
Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Zhang, Jin-Ping; Wu, Wei-Chun; Wang, Hao
2015-10-01
The purpose of this study was to investigate the diagnostic value of 3-dimensional (3D) speckle-tracking echocardiography for estimating left ventricular filling pressure in patients with coronary artery disease (CAD) and a preserved left ventricular ejection fraction. Altogether, 84 patients with CAD and 30 age- and sex-matched healthy control participants in sinus rhythm were recruited prospectively. All participants underwent conventional and 3D speckle-tracking echocardiography. Global strain values were automatically calculated by 3D speckle-tracking analysis. The left ventricular end-diastolic pressure (LVEDP) was determined invasively by left heart catheterization. Echocardiography and cardiac catheterization were performed within 24 hours. Compared with the controls, patients with CAD showed lower global longitudinal strain, global circumferential strain, global area strain, and global radial strain. Patients with CAD who had an elevated LVEDP had much lower levels of all 4 3D-speckle-tracking echocardiographic variables. Pearson correlation analysis revealed that the LVEDP correlated positively with the early transmitral flow velocity/early diastolic myocardial velocity (E/E') ratio, global longitudinal strain, global circumferential strain, and global area strain. It correlated negatively with global radial strain. Receiver operating characteristic curve analysis revealed that these 3D speckle-tracking echocardiographic indices could effectively predict elevated left ventricular filling pressure (LVEDP >15 mm Hg) in patients with CAD (areas under the curve: global longitudinal strain, 0.78; global radial strain, 0.77; global circumferential strain, 0.75; and global area strain, 0.74). These parameters, however, showed no advantages over the commonly used E/E' ratio (area under the curve, 0.84). Three-dimensional speckle-tracking echocardiography was a practical technique for predicting elevated left ventricular filling pressure, but it might not be superior to the commonly used E/E' ratio in patients with CAD who have a normal left ventricular ejection fraction. © 2015 by the American Institute of Ultrasound in Medicine.
Seeman, Tomáš; Hradský, Ondřej; Gilík, Jiří
2016-08-01
The aim of our study was to investigate whether nocturnal blood pressure (BP) dip is associated with increased left ventricular mass index and hypertrophy in children with hypertension (HT). We retrospectively reviewed data from all children with confirmed ambulatory HT in our center and performed ambulatory blood pressure monitoring (ABPM) and echocardiography at the same time. Left ventricular hypertrophy (LVH) was defined as left ventricular mass index (LVMI) ≥95th centile. Non-dipping phenomenon was defined as nocturnal BP dip <10 %. A total of 114 ABPM studies were included, the median age of children was 15.3 years (3.8-18.9), 80 children had renoparenchymal HT without end-stage renal failure, 34 had primary HT, and 27 studies were done on untreated children and 87 on treated children. Non-dipping phenomenon was present in 63 (55 %) studies (non-dippers). The LVMI adjusted for age was not significantly different between non-dippers and dippers (0.87 ± 0.03 vs. 0.81 ± 0.02, p = 0.13). Left ventricular hypertrophy was not significantly higher in non-dippers than in dippers (20 vs. 9 %, p = 0.12). Hypertensive children without end-stage renal failure with non-dipping phenomenon do not have increased prevalence of LVH or higher LVMI adjusted for age than hypertensive children with preserved nocturnal BP dip. • Adult and pediatric hypertensive patients with end-stage renal failure have often nocturnal blood pressure non-dipping phenomenon. • Non-dipping phenomenon is in patients with end-stage renal failure associated with increased prevalence of left ventricular hypertrophy. What is New: • Pediatric hypertensive patients without end-stage renal failure with blood pressure non-dipping phenomenon do not have increased prevalence of left ventricular hypertrophy.
Computational Modeling of Blast Wave Transmission Through Human Ear.
Leckness, Kegan; Nakmali, Don; Gan, Rong Z
2018-03-01
Hearing loss has become the most common disability among veterans. Understanding how blast waves propagate through the human ear is a necessary step in the development of effective hearing protection devices (HPDs). This article presents the first 3D finite element (FE) model of the human ear to simulate blast wave transmission through the ear. The 3D FE model of the human ear consisting of the ear canal, tympanic membrane, ossicular chain, and middle ear cavity was imported into ANSYS Workbench for coupled fluid-structure interaction analysis in the time domain. Blast pressure waveforms recorded external to the ear in human cadaver temporal bone tests were applied at the entrance of the ear canal in the model. The pressure waveforms near the tympanic membrane (TM) in the canal (P1) and behind the TM in the middle ear cavity (P2) were calculated. The model-predicted results were then compared with measured P1 and P2 waveforms recorded in human cadaver ears during blast tests. Results show that the model-derived P1 waveforms were in an agreement with the experimentally recorded waveforms with statistic Kurtosis analysis. The FE model will be used for the evaluation of HPDs in future studies.
Liakopoulos, Oliver J; Ho, Jonathan K; Yezbick, Aaron B; Sanchez, Elizabeth; Singh, Vivek; Mahajan, Aman
2010-11-01
Augmentation of coronary perfusion may improve right ventricular (RV) failure following acute increases of RV afterload. We investigated whether intra-aortic balloon counterpulsation (IABP) can improve cardiac function by enhancing myocardial perfusion and reversing compromised biventricular interactions using a model of acute pressure overload. In 10 anesthetized pigs, RV failure was induced by pulmonary artery constriction and systemic hypertension strategies with IABP, phenylephrine (PE), or the combination of both were tested. Systemic and ventricular hemodynamics [cardiac index(CI), ventricular pressures, coronary driving pressures (CDP)] were measured and echocardiography was used to assess tricuspid valve regurgitation, septal positioning (eccentricity index (ECI)), and changes in ventricular and septal dimensions and function [myocardial performance index (MPI), peak longitudinal strain]. Pulmonary artery constriction resulted in doubling of RV systolic pressure (54 ± 4mm Hg), RV distension, severe TR (4+) with decreased RV function (strain: -33%; MPI: +56%), septal flattening (Wt%: -35%) and leftward septal shift (ECI:1.36), resulting in global hemodynamic deterioration (CI: -51%; SvO(2): -26%), and impaired CDP (-30%; P<0.05). IABP support alone failed to improve RV function despite higher CDP (+33%; P<0.05). Systemic hypertension by PE improved CDP (+70%), RV function (strain: +22%; MPI: -21%), septal positioning (ECI:1.12) and minimized TR, but LV dysfunction (strain: -25%; MPI: +31%) occurred after LV afterloading (P<0.05). With IABP, less PE (-41%) was needed to maintain hypertension and CDP was further augmented (+25%). IABP resulted in LV unloading and restored LV function, and increased CI (+46%) and SvO(2) (+29%; P<0.05). IABP with minimal vasopressors augments myocardial perfusion pressure and optimizes RV function after pressure-induced failure. Copyright © 2010 Elsevier Inc. All rights reserved.
Park, Sung Min; Lee, Jin Hong; Choi, Seong Wook
2014-12-01
The ventricular electrocardiogram (v-ECG) was developed for long-term monitoring of heartbeats in patients with a left ventricular assist device (LVAD) and does not normally have the functionality necessary to detect additional heart irregularities that can progress to critical arrhythmias. Although the v-ECG has the benefits of physiological optimization and counterpulsation control, when abnormal heartbeats occur, the v-ECG does not show the distinct abnormal waveform that enables easy detection of an abnormal heartbeat among normal heartbeats on the conventional ECG. In this study, the v-ECGs of normal and abnormal heartbeats are compared with each other with respect to peak-to-peak voltage, area, and maximal slopes, and a new method to detect abnormal heartbeats is suggested. In a series of animal experiments with three porcine models (Yorkshire pigs weighing 30-40 kg), a v-ECG and conventional ECG were taken simultaneously during LVAD perfusion. Clinical experts found 104 abnormal heartbeats from the saved conventional ECG data and confirmed that the other 3159 heartbeats were normal. Almost all of the abnormal heartbeats were premature ventricular contractions (PVCs), and there was short-term tachycardia for 3 s. A personal computer was used to automatically detect abnormal heartbeats with the v-ECG according to the new method, and its results were compared with the clinicians' results. The new method found abnormal heartbeats with 90% accuracy, and less than 15% of the total PVCs were missed. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Baigorri, F; de Monte, A; Blanch, L; Fernández, R; Vallés, J; Mestre, J; Saura, P; Artigas, A
1994-11-01
To study the effect of positive end-expiratory pressure (PEEP) on right ventricular hemodynamics and ejection fraction in patients with chronic obstructive pulmonary disease and positive alveolar pressure throughout expiration by dynamic hyperinflation (auto-PEEP). Open, prospective, controlled trial. General intensive care unit of a community hospital. Ten patients sedated and paralyzed with an acute exacerbation of chronic obstructive pulmonary disease undergoing mechanical ventilation. Insertion of a pulmonary artery catheter modified with a rapid response thermistor and a radial arterial catheter. PEEP was then increased from 0 (PEEP 0) to auto-PEEP level (PEEP = auto-PEEP) and 5 cm H2O above that (PEEP = auto-PEEP +5). At each level of PEEP, airway pressures, flow and volume, hemodynamic variables (including right ventricular ejection fraction by thermodilution technique), and blood gas analyses were recorded. The mean auto-PEEP was 6.6 +/- 2.8 cm H2O and the total PEEP reached was 12.2 +/- 2.4 cm H2O. The degree of lung inflation induced by PEEP averaged 145 +/- 87 mL with PEEP = auto-PEEP and 495 +/- 133 mL with PEEP = auto-PEEP + 5. The PEEP = auto-PEEP caused a right ventricular end-diastolic pressure increase, but there was no other significant hemodynamic change. With PEEP = auto-PEEP + 5, there was a significant increase in intravascular pressures; this amount of PEEP reduced cardiac output (from 4.40 +/- 1.38 L/min at PEEP 0 to 4.13 +/- 1.48 L/min; p < .05). The cardiac output reduction induced by PEEP = auto-PEEP + 5 was > 10% in only five cases and this group of patients had significantly lower right ventricular volumes than the group with less cardiac output variation (right ventricular end-diastolic volume: 64 +/- 9 vs. 96 +/- 26 mL/m2; right ventricular end-systolic volume: 38 +/- 6 vs. 65 +/- 21 mL/m2; p < .05) without significant difference in the other variables that were measured. Neither right ventricular ejection fraction nor right ventricle volumes changed as PEEP increased, but there were marked interpatient differences and also pronounced changes in volume between stages in individual patients. In the study conditions, PEEP application up to values approaching auto-PEEP did not result in the impairment of right ventricular hemodynamics, while higher levels reduced cardiac output in selected patients.
Statistics of indicated pressure in combustion engine.
NASA Astrophysics Data System (ADS)
Sitnik, L. J.; Andrych-Zalewska, M.
2016-09-01
The paper presents the classic form of pressure waveforms in burn chamber of diesel engine but based on strict analytical basis for amending the displacement volume. The pressure measurement results are obtained in the engine running on an engine dynamometer stand. The study was conducted by a 13-phase ESC test (European Stationary Cycle). In each test phase are archived 90 waveforms of pressure. As a result of extensive statistical analysis was found that while the engine is idling distribution of 90 value of pressure at any value of the angle of rotation of the crankshaft can be described uniform distribution. In the each point of characteristic of the engine corresponding to the individual phases of the ESC test, 90 of the pressure for any value of the angle of rotation of the crankshaft can be described as normal distribution. These relationships are verified using tests: Shapiro-Wilk, Jarque-Bera, Lilliefors, Anderson-Darling. In the following part, with each value of the crank angle, are obtain values of descriptive statistics for the pressure data. In its essence, are obtained a new way to approach the issue of pressure waveform analysis in the burn chamber of engine. The new method can be used to further analysis, especially the combustion process in the engine. It was found, e.g. a very large variances of pressure near the transition from compression to expansion stroke. This lack of stationarity of the process can be important both because of the emissions of exhaust gases and fuel consumption of the engine.
Molina, Ezequiel J; Palma, Jon; Gupta, Dipin; Gaughan, John P; Houser, Steven; Macha, Mahender
2009-12-01
In a rat model of left ventricular pressure overload hypertrophy with biventricular failure, we studied the effects of intracoronary delivery of mesenchymal stem cells (MCS) upon right ventricular hemodynamic performance, profiles of local inflammation and apoptosis, and determinants of extracellular matrix remodeling. Sprague-Dawley rats underwent aortic banding and were followed by echocardiography. After a decrease in left ventricular fractional shortening of 25% from the baseline (relative 50% reduction), animals were randomized to an intracoronary injection of MSC (n=28) or PBS (n=20). Right ventricular hemodynamic assessment and measurement of local inflammatory markers, proapoptotic factors, and determinants of extracellular matrix remodeling were performed on post-transplantation day 7, 14, 21 or 28. MSC injection improved right ventricular systolic function in the MSC group compared to the control group (mean+/-SD, max dP/dt 772+/-272 mm Hg/s vs. 392+/-132 at 28 days, P<0.01). Diastolic function was similarly improved (mean+/-SD, max -dP/dt -558+/-171 mm Hg/s vs. -327+/-131 at 28 days, P<0.05). Right ventricular levels of IL-1, IL-6, TNF-alpha, bax, bak and p38 were significantly decreased in the MSC treated animals. Expression of MMP-3, MMP-6, MMP-9, TIMP-1 and TIMP-3 declined in the MSC group compared with controls after 28 days. In this model of left ventricular pressure overload hypertrophy and biventricular failure, intracoronary delivery of MSC was associated with an improvement in the right ventricular hemodynamic performance, profiles of local inflammation and apoptosis, and determinants of extracellular matrix remodeling.
Kamoi, Shun; Pretty, Christopher; Balmer, Joel; Davidson, Shaun; Pironet, Antoine; Desaive, Thomas; Shaw, Geoffrey M; Chase, J Geoffrey
2017-04-24
Pressure contour analysis is commonly used to estimate cardiac performance for patients suffering from cardiovascular dysfunction in the intensive care unit. However, the existing techniques for continuous estimation of stroke volume (SV) from pressure measurement can be unreliable during hemodynamic instability, which is inevitable for patients requiring significant treatment. For this reason, pressure contour methods must be improved to capture changes in vascular properties and thus provide accurate conversion from pressure to flow. This paper presents a novel pressure contour method utilizing pulse wave velocity (PWV) measurement to capture vascular properties. A three-element Windkessel model combined with the reservoir-wave concept are used to decompose the pressure contour into components related to storage and flow. The model parameters are identified beat-to-beat from the water-hammer equation using measured PWV, wave component of the pressure, and an estimate of subject-specific aortic dimension. SV is then calculated by converting pressure to flow using identified model parameters. The accuracy of this novel method is investigated using data from porcine experiments (N = 4 Pietrain pigs, 20-24.5 kg), where hemodynamic properties were significantly altered using dobutamine, fluid administration, and mechanical ventilation. In the experiment, left ventricular volume was measured using admittance catheter, and aortic pressure waveforms were measured at two locations, the aortic arch and abdominal aorta. Bland-Altman analysis comparing gold-standard SV measured by the admittance catheter and estimated SV from the novel method showed average limits of agreement of ±26% across significant hemodynamic alterations. This result shows the method is capable of estimating clinically acceptable absolute SV values according to Critchely and Critchely. The novel pressure contour method presented can accurately estimate and track SV even when hemodynamic properties are significantly altered. Integrating PWV measurements into pressure contour analysis improves identification of beat-to-beat changes in Windkessel model parameters, and thus, provides accurate estimate of blood flow from measured pressure contour. The method has great potential for overcoming weaknesses associated with current pressure contour methods for estimating SV.
Kerckhoffs, Roy C. P.; Neal, Maxwell L.; Gu, Quan; Bassingthwaighte, James B.; Omens, Jeff H.; McCulloch, Andrew D.
2010-01-01
In this study we present a novel, robust method to couple finite element (FE) models of cardiac mechanics to systems models of the circulation (CIRC), independent of cardiac phase. For each time step through a cardiac cycle, left and right ventricular pressures were calculated using ventricular compliances from the FE and CIRC models. These pressures served as boundary conditions in the FE and CIRC models. In succeeding steps, pressures were updated to minimize cavity volume error (FE minus CIRC volume) using Newton iterations. Coupling was achieved when a predefined criterion for the volume error was satisfied. Initial conditions for the multi-scale model were obtained by replacing the FE model with a varying elastance model, which takes into account direct ventricular interactions. Applying the coupling, a novel multi-scale model of the canine cardiovascular system was developed. Global hemodynamics and regional mechanics were calculated for multiple beats in two separate simulations with a left ventricular ischemic region and pulmonary artery constriction, respectively. After the interventions, global hemodynamics changed due to direct and indirect ventricular interactions, in agreement with previously published experimental results. The coupling method allows for simulations of multiple cardiac cycles for normal and pathophysiology, encompassing levels from cell to system. PMID:17111210
Doppler echocardiographic analysis of left ventricular filling in treated hypertensive patients.
Phillips, R A; Coplan, N L; Krakoff, L R; Yeager, K; Ross, R S; Gorlin, R; Goldman, M E
1987-02-01
Early detection and prevention of cardiac dysfunction is an important goal in the management of hypertensive patients. In this study, Doppler echocardiography was used to evaluate the pattern of left ventricular diastolic filling in 38 subjects: 18 treated hypertensive patients (blood pressure 141 +/- 17/83 +/- 10 mm Hg, mean +/- SD) without other coronary risk factors and 20 risk-free normotensive subjects of similar age (47 +/- 10 and 49 +/- 13 years, respectively). Peak velocity of late left ventricular filling due to the atrial contraction was greater in hypertensive compared with normotensive subjects (69 +/- 14 versus 52 +/- 13 cm/s; p less than 0.001). Peak velocity of late filling was significantly greater in hypertensive versus normotensive subjects in those aged 50 years or younger and those older than age 50 (65 +/- 12 versus 50 +/- 11; p less than 0.01 and 75 +/- 15 versus 56 +/- 15 cm/s; p less than 0.05, respectively). In hypertensive subjects, peak velocity of late filling did not correlate with routine indexes of hypertensive heart disease (including posterior wall thickness and left ventricular mass), systolic and diastolic blood pressure or duration of hypertension. These results indicate that increased velocity of late left ventricular filling may be independent of left ventricular hypertrophy and persist despite effective blood pressure control.
The effects of hypoxemia on myocardial blood flow during exercise.
Paridon, S M; Bricker, J T; Dreyer, W J; Reardon, M; Smith, E O; Porter, C B; Michael, L; Fisher, D J
1989-03-01
We evaluated the adequacy of regional and transmural blood flow during exercise and rapid pacing after 1 wk of hypoxemia. Seven mature mongrel dogs were made hypoxemic (mean O2 saturation = 72.4%) by anastomosis of left pulmonary artery to left atrial appendage. Catheters were placed in the left atrium, right atrium, pulmonary artery, and aorta. Atrial and ventricular pacing wires were placed. An aortic flow probe was placed to measure cardiac output. Ten nonshunted dogs, similarly instrumented, served as controls. Recovery time was approximately 1 wk. Cardiac output, mean aortic pressure, and oxygen saturation were measured at rest, with ventricular pacing, atrial pacing, and with treadmill exercise. Ventricular and atrial pace and exercise were at a heart rate of 200. Right ventricular free wall, left ventricular free wall, and septal blood flow were measured with radionuclide-labeled microspheres. Cardiac output, left atrial blood pressure, and aortic blood pressure were similar between the two groups of dogs in all testing states. Myocardial blood flow was significantly higher in the right and left ventricular free wall in the hypoxemic animals during resting and exercise testing states. Myocardial oxygen delivery was similar between the two groups of animals. Pacing resulted in an increase in myocardial blood flow in the control animals but not the hypoxemic animals.(ABSTRACT TRUNCATED AT 250 WORDS)
Non-invasive determination of instantaneous brachial blood flow using the oscillometric method.
Liu, Shing-Hong; Wang, Jia-Jung; Cheng, Da-Chuan
2009-08-01
The oscillometric method has been widely used to measure arterial systolic and diastolic blood pressures, but its potential for arterial blood flow measurements still remains to be explored. The aim of this study was to non-invasively determine arterial blood flow using an oscillometric blood flow measurement system. The system consists of a pneumatic elastic cuff, an air-pumping motor, a releaser valve, a pressure transducer, and an airflow meter. To build a non-linear cuff model, we measured airflow pumped into the pneumatic cuff and cuff pressure using an airflow meter and pressure transducer during the inflation period, respectively. During the deflation period, only the pressure transducer was used to record cuff pressure. Based on the cuff model, the oscillometric blood flow waveform was obtained by integrating the oscillometric pressure waveform. We compared arterial blood flow derived from the maximum amplitude of the oscillometric blood flow waveform with Doppler-measured blood flow calculated with the diameters and blood velocities of the brachial arteries in 32 subjects who underwent diagnostic evaluations for peripheral arterial embolism. A linear correlation coefficient of r = 0.716 was found between the oscillometry- and Doppler-based blood flow measurements in the 32 subjects. These results suggest that blood flow passing through the brachial artery can be quantified non-invasively using the oscillometric approach after appropriate calibration.
Is Doppler tissue velocity during early left ventricular filling preload independent?
NASA Technical Reports Server (NTRS)
Yalcin, F.; Kaftan, A.; Muderrisoglu, H.; Korkmaz, M. E.; Flachskampf, F.; Garcia, M.; Thomas, J. D.
2002-01-01
BACKGROUND: Transmitral Doppler flow indices are used to evaluate diastolic function. Recently, velocities measured by Doppler tissue imaging have been used as an index of left ventricular relaxation. OBJECTIVE: To determine whether Doppler tissue velocities are influenced by alterations in preload. METHODS: Left ventricular preload was altered in 17 patients (all men, mean (SD) age, 49 (8) years) during echocardiographic measurements of left ventricular end diastolic volume, maximum left atrial area, peak early Doppler filling velocity, and left ventricular myocardial velocities during early filling. Preload altering manoeuvres included Trendelenberg (stage 1), reverse Trendelenberg (stage 2), and amyl nitrate (stage 3). Systolic blood pressure was measured at each stage. RESULTS: In comparison with baseline, left ventricular end diastolic volume (p = 0.001), left atrial area (p = 0.003), peak early mitral Doppler filling velocity (p = 0.01), and systolic blood pressures (p = 0.001) were all changed by preload altering manoeuvres. Only left ventricular myocardial velocity during early filling remained unchanged by these manoeuvres. CONCLUSIONS: In contrast to standard transmitral Doppler filling indices, Doppler tissue early diastolic velocities are not significantly affected by physiological manoeuvres that alter preload. Thus Doppler tissue velocities during early left ventricular diastole may provide a better index of diastolic function in cardiac patients by providing a preload independent assessment of left ventricular filling.
Right ventricular function during acute exacerbation of severe equine asthma.
Decloedt, A; Borowicz, H; Slowikowska, M; Chiers, K; van Loon, G; Niedzwiedz, A
2017-09-01
Pulmonary hypertension has been described in horses with severe equine asthma, but its effect on the right ventricle has not been fully elucidated. To evaluate right ventricular structure and function after a 1-week period of pulmonary hypertension secondary to acute exacerbation of severe equine asthma. Prospective study. A clinical episode of severe equine asthma was induced experimentally in six susceptible horses. Examinations in remission and on day 7 of the clinical episode included a physical examination with clinical scoring, echocardiography, arterial blood gas measurements, venous blood sampling for cardiac biomarkers, intracardiac pressure measurements, right ventricular and right atrial myocardial biopsies, airway endoscopy and bronchoalveolar lavage. After 1 month of recovery, physical examination, echocardiography and cardiac biomarker analysis were repeated. Echocardiographic and pressure measurements were compared with those in 10 healthy control horses. All horses developed clinical signs of acute pulmonary obstruction. Right heart pressures increased significantly. Altered right ventricular function could be detected by tissue Doppler and speckle tracking echocardiography. Cardiac troponin concentrations did not increase significantly, but were highly elevated in one horse which exercised in the paddock prior to sampling. Focal neutrophil infiltration was present in two myocardial samples. Even in remission, asthmatic horses showed a thicker right ventricular wall, an increased left ventricular end-systolic eccentricity index at chordal level and decreased right ventricular longitudinal strain compared with controls. The induced clinical episode was rather mild and the number of horses was limited because of the invasive nature of the study. Pulmonary obstruction in asthmatic horses induces pulmonary hypertension with right ventricular structural and functional changes. © 2017 EVJ Ltd.
Meierhofer, Christian; Tavakkoli, Timon; Kühn, Andreas; Ulm, Kurt; Hager, Alfred; Müller, Jan; Martinoff, Stefan; Ewert, Peter; Stern, Heiko
2017-12-01
Good quality of life correlates with a good exercise capacity in daily life in patients with tetralogy of Fallot (ToF). Patients after correction of ToF usually develop residual defects such as pulmonary regurgitation or stenosis of variable severity. However, the importance of different hemodynamic parameters and their impact on exercise capacity is unclear. We investigated several hemodynamic parameters measured by cardiovascular magnetic resonance (CMR) and echocardiography and evaluated which parameter has the most pronounced effect on maximal exercise capacity determined by cardiopulmonary exercise testing (CPET). 132 patients with ToF-like hemodynamics were tested during routine follow-up with CMR, echocardiography and CPET. Right and left ventricular volume data, ventricular ejection fraction and pulmonary regurgitation were evaluated by CMR. Echocardiographic pressure gradients in the right ventricular outflow tract and through the tricuspid valve were measured. All data were classified and correlated with the results of CPET evaluations of these patients. The analysis was performed using the Random Forest model. In this way, we calculated the importance of the different hemodynamic variables related to the maximal oxygen uptake in CPET (VO 2 %predicted). Right ventricular pressure showed the most important influence on maximal oxygen uptake, whereas pulmonary regurgitation and right ventricular enddiastolic volume were not important hemodynamic variables to predict maximal oxygen uptake in CPET. Maximal exercise capacity was only very weakly influenced by right ventricular enddiastolic volume and not at all by pulmonary regurgitation in patients with ToF. The variable with the most pronounced influence was the right ventricular pressure.
Oshorov, A V; Popugaev, K A; Savin, I A; Potapov, A A
2016-01-01
"Standard" assessment of ICP by measuring liquor ventricular pressure recently questioned. THE OBJECTIVE OF THE STUDY: Compare the values of ventricular and parenchymal ICP against the closure of open liquor drainage and during active CSF drainage. Examined 7 patients with TBI and intracranial hypertension syndrome, GCS 5.6 ± 1.2 points, 4.2 ± age 33 years. Compared parenchymal and ventricular ICP in three time periods: 1--during closure of ventricular drainage, 2--during of the open drains and drainage at the level of 14-15 mmHg, 3--during the period of active drainage. When comparing two methods of measurement used Bland-Altman method. 1. During time period of the closed drainage correlation coefficient was r = 0.83, p < 0.001. Bland-Altman method: the difference of the two measurements is equal to the minimum and 0.7 mm Hg, the standard deviation of 2.02 mm Hg 2. During time period of the open drainage was reduction of the correlation coefficient to r = 0.46, p < 0.01. Bland-Altman method: an increase in the difference of the two measurements to -0.84 mmHg, standard deviation 2.8 mm Hg 3. During time period of the active drainage of cerebrospinal fluid was marked difference between methods of measurement. Bland-Altman method: the difference was 8.64 mm Hg, and a standard deviation of 2.6 mm Hg. 1. During the closure of the ventricular drainage were good correlation between ventricular and parenchymal ICR 2. During open the liquor drainage correlation between the two methods of measuring the intracranial pressure is reduced. 3. During the active CSF drainage correlation between the two methods of measuring intracranial pressure can be completely lost. Under these conditions, CSF pressure is not correctly reflect the ICP 4. For an accurate and continuous measurement of intracranial pressure on the background of the active CSF drainage should be carried out simultaneous parenchymal ICP measurement.
Fukamachi, Kiyotaka; Popović, Zoran B; Inoue, Masahiro; Doi, Kazuyoshi; Schenk, Soren; Ootaki, Yoshio; Kopcak, Michael W; McCarthy, Patrick M
2004-03-01
The objective of this study was to evaluate the changes in mitral annular and left ventricular dimensions and left ventricular pressure-volume relations produced by the Myocor Coapsys device that has been developed to treat functional mitral regurgitation (MR) off-pump. The Coapsys device, which consists of anterior and posterior epicardial pads connected by a sub-valvular chord, was implanted in seven dogs with functional MR resulting from pacing induced cardiomyopathy. The Coapsys device was then sized by drawing the posterior leaflet and annulus toward the anterior leaflet. During sizing, MR grade was assessed using color flow Doppler echocardiography. Final device size was selected when MR was eliminated or minimized. Following implantation, heart failure was maintained by continued pacing for a period of 8 weeks. Mitral annular and left ventricular dimensions and left ventricular pressure-volume relations were evaluated by two-dimensional echocardiography and a conductance catheter, respectively, at pre-sizing, post-sizing, and after 8 weeks. All implants were performed on beating hearts without cardiopulmonary bypass. Mean MR grade was reduced from 2.9+/-0.7 at pre-sizing to 0.7+/-0.8 at post-sizing (P<0.001), and was maintained at 0.8+/-0.8 after 8 weeks (P<0.01). The septal-lateral dimensions were significantly reduced at both mitral annular level [2.4+/-0.2 cm at pre-sizing, 1.5+/-0.3 cm at post-sizing (P<0.001) and 1.8+/-0.3 cm after 8 weeks (P<0.05)] and mid-papillary level [4.1+/-0.4 cm at pre-sizing, 2.4+/-0.2 cm at post-sizing (P<0.001) and 3.3+/-0.4 cm after 8 weeks (P<0.001)]. The end-systolic pressure-volume relation shifted leftward at post-sizing with a significantly steeper slope (P=0.03). There was a significant (P=0.03) leftward shift of the end-diastolic pressure-volume relation at post-sizing. After 8 weeks, these changes in pressure-volume relations tended to return to pre-sizing relations. The Coapsys device significantly reduced MR by treating both the mitral annular dilatation and the papillary muscle displacement. Despite these significant dimensional changes, the Coapsys device did not negatively affect the left ventricular pressure-volume relations.
Patient characteristics associated with false arrhythmia alarms in intensive care.
Harris, Patricia R; Zègre-Hemsey, Jessica K; Schindler, Daniel; Bai, Yong; Pelter, Michele M; Hu, Xiao
2017-01-01
A high rate of false arrhythmia alarms in the intensive care unit (ICU) leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds) at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and ventricular bradycardia) as true or false. Total monitoring time for each patient was measured, and the number of false alarms per hour was calculated for these six alarm types. Medical records were examined to acquire data on patient characteristics. A total of 461 unique patients (mean age =60±17 years) were enrolled, generating a total of 2,558,760 alarms, including all levels of arrhythmia, parameter, and technical alarms. There were 48,404 hours of patient monitoring time, and an average overall alarm rate of 52 alarms/hour. Investigators annotated 12,671 arrhythmia alarms; 11,345 (89.5%) were determined to be false. Two hundred and fifty patients (54%) generated at least one of the six annotated alarm types. Two patients generated 6,940 arrhythmia alarms (55%). The number of false alarms per monitored hour for patients' annotated arrhythmia alarms ranged from 0.0 to 7.7, and the duration of these false alarms per hour ranged from 0.0 to 158.8 seconds. Patient characteristics were compared in relation to 1) the number and 2) the duration of false arrhythmia alarms per 24-hour period, using nonparametric statistics to minimize the influence of outliers. Among the significant associations were the following: age ≥60 years ( P =0.013; P =0.034), confused mental status ( P <0.001 for both comparisons), cardiovascular diagnoses ( P <0.001 for both comparisons), electrocardiographic (ECG) features, such as wide ECG waveforms that correspond to ventricular depolarization known as QRS complex due to bundle branch block (BBB) ( P =0.003; P =0.004) or ventricular paced rhythm ( P =0.002 for both comparisons), respiratory diagnoses ( P =0.004 for both comparisons), and support with mechanical ventilation, including those with primary diagnoses other than respiratory ones ( P <0.001 for both comparisons). Patients likely to trigger a higher number of false arrhythmia alarms may be those with older age, confusion, cardiovascular diagnoses, and ECG features that indicate BBB or ventricular pacing, respiratory diagnoses, and mechanical ventilatory support. Algorithm improvements could focus on better noise reduction (eg, motion artifact with confused state) and distinguishing BBB and paced rhythms from ventricular arrhythmias. Increasing awareness of patient conditions that apparently trigger a higher rate of false arrhythmia alarms may be useful for reducing unnecessary noise and improving alarm management.
McGrath, Susan P; Ryan, Kathy L; Wendelken, Suzanne M; Rickards, Caroline A; Convertino, Victor A
2011-02-01
The primary objective of this study was to determine whether alterations in the pulse oximeter waveform characteristics would track progressive reductions in central blood volume. We also assessed whether changes in the pulse oximeter waveform provide an indication of blood loss in the hemorrhaging patient before changes in standard vital signs. Pulse oximeter data from finger, forehead, and ear pulse oximeter sensors were collected from 18 healthy subjects undergoing progressive reduction in central blood volume induced by lower body negative pressure (LBNP). Stroke volume measurements were simultaneously recorded using impedance cardiography. The study was conducted in a research laboratory setting where no interventions were performed. Pulse amplitude, width, and area under the curve (AUC) features were calculated from each pulse wave recording. Amalgamated correlation coefficients were calculated to determine the relationship between the changes in pulse oximeter waveform features and changes in stroke volume with LBNP. For pulse oximeter sensors on the ear and forehead, reductions in pulse amplitude, width, and area were strongly correlated with progressive reductions in stroke volume during LBNP (R(2) ≥ 0.59 for all features). Changes in pulse oximeter waveform features were observed before profound decreases in arterial blood pressure. The best correlations between pulse features and stroke volume were obtained from the forehead sensor area (R(2) = 0.97). Pulse oximeter waveform features returned to baseline levels when central blood volume was restored. These results support the use of pulse oximeter waveform analysis as a potential diagnostic tool to detect clinically significant hypovolemia before the onset of cardiovascular decompensation in spontaneously breathing patients.
Modeling measured glottal volume velocity waveforms.
Verneuil, Andrew; Berry, David A; Kreiman, Jody; Gerratt, Bruce R; Ye, Ming; Berke, Gerald S
2003-02-01
The source-filter theory of speech production describes a glottal energy source (volume velocity waveform) that is filtered by the vocal tract and radiates from the mouth as phonation. The characteristics of the volume velocity waveform, the source that drives phonation, have been estimated, but never directly measured at the glottis. To accomplish this measurement, constant temperature anemometer probes were used in an in vivo canine constant pressure model of phonation. A 3-probe array was positioned supraglottically, and an endoscopic camera was positioned subglottically. Simultaneous recordings of airflow velocity (using anemometry) and glottal area (using stroboscopy) were made in 3 animals. Glottal airflow velocities and areas were combined to produce direct measurements of glottal volume velocity waveforms. The anterior and middle parts of the glottis contributed significantly to the volume velocity waveform, with less contribution from the posterior part of the glottis. The measured volume velocity waveforms were successfully fitted to a well-known laryngeal airflow model. A noninvasive measured volume velocity waveform holds promise for future clinical use.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wackerbarth, David
Sandia National Laboratories has developed a computer program to review, reduce and manipulate waveform data. PlotData is designed for post-acquisition waveform data analysis. PlotData is both a post-acquisition and an advanced interactive data analysis environment. PlotData requires unidirectional waveform data with both uniform and discrete time-series measurements. PlotData operates on a National Instruments' LabVIEW™ software platform. Using PlotData, the user can capture waveform data from digitizing oscilloscopes over a GPIB, USB and Ethernet interface from Tektronix, Lecroy or Agilent scopes. PlotData can both import and export several types of binary waveform files including, but not limited to, Tektronix .wmf files,more » Lecroy.trc files and xy pair ASCIIfiles. Waveform manipulation includes numerous math functions, integration, differentiation, smoothing, truncation, and other specialized data reduction routines such as VISAR, POV, PVDF (Bauer) piezoelectric gauges, and piezoresistive gauges such as carbon manganin pressure gauges.« less
Schreuder, Jan J; Castiglioni, Alessandro; Maisano, Francesco; Steendijk, Paul; Donelli, Andrea; Baan, Jan; Alfieri, Ottavio
2005-01-01
Surgical left ventricular restoration by means of endoventricular patch aneurysmectomy in patients with postinfarction aneurysm should result in acute improved left ventricular performance by decreasing mechanical dyssynchrony and increasing energy efficiency. Nine patients with left ventricular postinfarction aneurysm were studied intraoperatively before and after ventricular restoration with a conductance volume catheter to analyze pressure-volume relationships, energy efficiency, and mechanical dyssynchrony. The end-systolic elastance was used as a load-independent index of contractile state. Left ventricular energy efficiency was calculated from stroke work and total pressure-volume area. Segmental volume changes perpendicular to the long axis were used to calculate mechanical dyssynchrony. Statistical analysis was performed with the paired t test and least-squares linear regression. Endoventricular patch aneurysmectomy reduced end-diastolic volume by 37% (P < .001), with unchanged stroke volume. Systolic function improved, as derived from increased +dP/dt(max), by 42% (P < .03), peak ejection rate by 28% (P < .02), and ejection fraction by 16% (P < .0002). Early diastolic function improved, as shown by reduction of -dP/dt(max) by 34% (P < .006) and shortened tau by 30% (P < .001). Left ventricular end-systolic elastance increased from 1.2 +/- 0.6 to 2.2 +/- 1 mm Hg/mL (P < .001). Left ventricular energy efficiency increased by 36% (P < .002). Left ventricular mechanical dyssynchrony decreased during systole by 33% (P < .001) and during diastole by 20% (P < .005). Left ventricular restoration induced acute improvements in contractile state, energy efficiency, and relaxation, together with a decrease in left ventricular mechanical dyssynchrony.
Response of the Cardiovascular System to Vibration and Combined Stresses
1975-08-31
Canines were chronically instrumented for continuous measurements of ascending aortic flow ( Zepeda ), left ventricular pressure (Konigsberg), circum- flex...different animals. Each dog was chronically instrumented for continuous measuremernt of ascending aortic flow ( Zepeda ), left ventricular pressure...vibration protocol as those animals restrained vertically. METHODS Canines (16 to 22 kg) were chronically instrumented with electromagnetic flow cuffs ( Zepeda
Yokoyama, Yoshimasa; Kawaguchi, Osamu; Kitao, Takashi; Kimura, Taro; Steinseifer, Ulrich; Takatani, Setsuo
2010-09-01
The ventricular performance is dependent on the drainage effect of rotary blood pumps (RBPs) and the performance of RBPs is affected by the ventricular pulsation. In this study, the interaction between the ventricle and RBPs was examined using the pressure-volume (P-V) diagram of the ventricle and dynamic head pressure-bypass flow (H-Q) curves (H, head pressure: arterial pressure minus ventricular pressure vs. Q, bypass flow) of the RBPs. We first investigated the relationships in a mock loop with a passive fill ventricle, followed by validation in ex vivo animal experiments. An apical drainage cannula with a micro-pressure sensor was especially fabricated to obtain ventricular pressure, while three pairs of ultrasonic crystals placed on the heart wall were used to derive ventricular volume. The mock loop-configured ventricular apical-descending aorta bypass revealed that the external work of the ventricle expressed by the area inside the P-V diagrams (EW(Heart) ) correlated strongly with the area inside dynamic H-Q curves (EW(VAD)), with the coefficients of correlation being R² = 0.869 ∼ 0.961. The results in the mock loop were verified in the ex vivo studies using three Shiba goats (10-25 kg in body weight), showing the correlation coefficients of R² = 0.802 ∼ 0.817. The linear regression analysis indicated that the increase in the bypass flow reduced pulsatility in the ventricle expressed in EW(Heart) as well as in EW(VAD) . Experimental results, both mock loop and animal studies, showed that the interaction between cardiac external work and H-Q performance of RBPs can be expressed by the relationships "EW(Heart) versus EW(VAD) ." The pulsatile nature of the native heart can be expressed in the area underneath the H-Q curves of RBPs EW(VAD) during left heart bypass indicating the status of the level of assistance by RBPs and the native heart function. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
2001-12-01
instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to...isoflurane in 100% oxy- gen) prior to insertion of the high -fidelity pressure micromanome- ters during cardiac fluoroscopy. Once the micromanometer trans...and allowed to fully recover from the isoflurane seda- tion for a period of 60 min, during which blood pressure and aortic flow were monitored to ensure
Effects of smoking on arterial distensibility, central aortic pressures and left ventricular mass.
Markus, Marcello Ricardo Paulista; Stritzke, Jan; Baumeister, Sebastian Edgar; Siewert, Ulrike; Baulmann, Johannes; Hannemann, Anke; Schipf, Sabine; Meisinger, Christa; Dörr, Marcus; Felix, Stephan Burkhart; Keil, Ulrich; Völzke, Henry; Hense, Hans-Werner; Schunkert, Heribert
2013-10-03
The effects of smoking on central aortic pressures and the age-related increase in left ventricular mass (LVM) are largely unknown. We studied the relationship between smoking, arterial distensibility, central aortic pressures and left ventricular mass in two population-based studies. Data was obtained from two German population-based studies (KORA and SHIP, participants' ages 25-84 years). We identified 114 normotensive current smokers and 185 normotensive all-time non-smokers in KORA as well as 400 and 588 such individuals in SHIP. Echocardiographic LVM was obtained at baseline (T0) and follow-up after ten years (T1) in KORA and at follow-up (T1) in SHIP. Additionally, pulse-wave analysis-based central aortic pressure and augmentation index (AIx) were measured at T1 in KORA. Cross-sectional analysis, using KORA T0 and SHIP T1, revealed in both studies a higher covariate-adjusted LVM and left ventricular mass index (LVMI) in smokers as compared with non-smokers. Moreover, in the KORA T1 examination, the smokers demonstrated a more pronounced increase, relative to baseline, of LVM (+13.5%) and LVMI (+13.4%) compared to non-smokers (+8.59% and +8.65%; p=0.036 and 0.042, respectively). Additionally, at KORA T1 smokers had a higher central systolic blood pressure and higher AIx than non-smokers (p=0.012 and p=0.001, respectively). The difference in central aortic pressure due to enhanced and more prolonged wave reflection may explain our finding of a further pronounced increase in left ventricular wall thickness and mass over time in smokers. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Prediction of wound healing after minor amputations of the diabetic foot.
Caruana, Luana; Formosa, Cynthia; Cassar, Kevin
2015-08-01
To identify any significant differences in physiological test results between healing and non healing amputation sites. A single center prospective non-experimental study design was conducted on fifty subjects living with type 2 diabetes and requiring a forefoot or toe amputation. Subjects underwent non-invasive physiological testing preoperatively. These included assessment of pedal pulses, preoperative arterial spectral waveforms at the ankle, absolute toe pressures, toe-brachial pressure index and ankle-brachial pressure index. After 6 weeks, patients were examined to assess whether the amputation site was completely healed, was healing, had developed complications, or did not heal. There was no significant difference in ABPI between the healed/healing and the non-healing groups. Mean TBI (p=0.031) and toe pressure readings (p=0.014) were significantly higher in the healed/healing group compared to the non healing group. A significant difference was also found in ankle spectral waveforms between the two groups (p=0.028). TBIs, toe pressures and spectral waveforms at the ankle are better predictors of likelihood of healing and non-healing after minor amputation than ABPIs. ABPI alone is a poor indicator of the likelihood of healing of minor amputations and should not be relied on to determine need for revascularization procedures before minor amputation. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lane, Stephen J.; James, Mike R.; Corder, Steven B.
2013-09-01
We demonstrate the rise and expansion of a gas slug as a fluid dynamic source mechanism for infrasonic signals generated by gas puffing and impulsive explosions at Stromboli. The fluid dynamics behind the rise, expansion and burst of gas slugs in the confines of an experimental tube can be characterised into different regimes. Passive expansion occurs for small gas masses, where negligible dynamic gas over-pressure develops during bubble ascent and, prior to burst, meniscus oscillation forms an important infrasonic source. With increasing gas mass, a transition regime emerges where dynamic gas over-pressure is significant. For larger gas masses, this regime transforms to fully explosive behaviour, where gas over-pressure dominates as an infrasonic source and bubble bursting is not a critical factor. The rate of change of excess pressure in the experimental tube was used to generate synthetic infrasonic waveforms. Qualitatively, the waveforms compare well to infrasonic waveforms measured from a range of eruptions at Stromboli. Assuming pressure continuity during flow through the vent, and applying dimensionless arguments from the first-order experiments, allows estimation of eruption metrics from infrasonic signals measured at Stromboli. Values of bubble length, gas mass and over-pressure calculated from infrasonic signals are in excellent agreement with those derived by independent means for eruptions at Stromboli, therefore providing a method of estimating eruption metrics from infrasonic measurement.
Yam, Man-Ching; So, Hung-Kwan; Kwok, Sit-Yee; Lo, Fung-Cheung; Mok, Chi-Fung; Leung, Chuk-Kwan; Yip, Wai-Kwok; Sung, Yn-Tz
2018-06-01
In our previous study, the prevalence of childhood masked hypertension was 11%. This study aims to assess the left ventricular mass index of persistent masked hypertension and determine the factors of elevated left ventricular mass index in Hong Kong Chinese adolescents from a community cohort. Community prospective cohort study, follow-up of a case-control study in community. Patients with masked hypertension at baseline were invited to recheck ambulatory blood pressure for the persistence of masked hypertension. A total of 144 out of 165 patients with masked hypertension in the 2011/2012 ambulatory blood pressure survey consented to participate in the study. In all, 48 patients were found to have persistent masked hypertension by ambulatory blood pressure rechecking and were matched with normotensive controls by sex, age, and body height. The left ventricular mass (117.3±39.9 g versus 87.0±28.2 g versus 102.0±28.2 g) and left ventricular mass index (30.1±8.4 g/m2.7 versus 23.9±6.3 g/m2.7 versus 25.1±5.7 g/m2.7) were significantly higher in the persistent masked hypertension group (p<0.0001) compared with the patients without persistent masked hypertension and controls. In multivariate linear regression analysis, left ventricular mass index was found to be higher in male gender (β=4.874, p<0.0001) and the patients with persistent masked hypertension (β=2.796, p=0.003). In addition, left ventricular mass index was positively associated with body mass index z-score (β=3.045, p<0.0001) and low-density lipoprotein cholesterol concentration (β=1.634, p=0.015). Persistent masked hypertension in adolescents is associated with elevated left ventricular mass index.
2013-08-08
pressure; SpO2, oxygen saturation of arterial blood by pulse oximetry. -75-60-45-30-15Baseline 40 50 60 70 80 90 100 HT LT LBNP, mmHg S tr o ke V o...systolic arterial blood pressure (mmHg) generated from the Finometer. R-R intervals (ms) were used to calculate heart rate (beats/min). Oxygen saturation of...The CRI can be integrated into any standard monitor that generates an arterial waveform, including a finger pulse oximeter that is available in the
NASA Astrophysics Data System (ADS)
Sapozhnikov, Oleg A.; Khokhlova, Vera A.; Cathignol, Dominique
2004-05-01
A classical effect of nonlinear acoustics is that a plane sinusoidal acoustic wave propagating in a nonlinear medium transforms to a sawtooth wave with one shock per cycle. However, the waveform evolution can be quite different in the near field of a plane source due to diffraction. Previous numerical simulations of nonlinear acoustic waves in the near field of a circular piston source predict the development of two shocks per wave cycle [Khokhlova et al., J. Acoust. Soc. Am. 110, 95-108 (2001)]. Moreover, at some locations the peak pressure may be up to 4 times the source amplitude. The motivation of this work was to experimentally verify and further explain the phenomena of the nonlinear waveform distortion. Measurements were conducted in water with a 47-mm-diameter unfocused transducer, working at 1-MHz frequency. For pressure amplitudes higher than 0.5 MPa, two shocks per cycle were observed in the waveform beyond the last minimum of the fundamental harmonic amplitude. With the increase of the observation distance, these two shocks collided and formed one shock (per cycle), i.e., the waveform developed into the classical sawtooth wave. The experimental results were in a very good agreement with the modeling based on the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation.
Yuldashev, Petr; Karzova, Maria; Khokhlova, Vera; Ollivier, Sébastien; Blanc-Benon, Philippe
2015-06-01
A Mach-Zehnder interferometer is used to measure spherically diverging N-waves in homogeneous air. An electrical spark source is used to generate high-amplitude (1800 Pa at 15 cm from the source) and short duration (50 μs) N-waves. Pressure waveforms are reconstructed from optical phase signals using an Abel-type inversion. It is shown that the interferometric method allows one to reach 0.4 μs of time resolution, which is 6 times better than the time resolution of a 1/8-in. condenser microphone (2.5 μs). Numerical modeling is used to validate the waveform reconstruction method. The waveform reconstruction method provides an error of less than 2% with respect to amplitude in the given experimental conditions. Optical measurement is used as a reference to calibrate a 1/8-in. condenser microphone. The frequency response function of the microphone is obtained by comparing the spectra of the waveforms resulting from optical and acoustical measurements. The optically measured pressure waveforms filtered with the microphone frequency response are in good agreement with the microphone output voltage. Therefore, an optical measurement method based on the Mach-Zehnder interferometer is a reliable tool to accurately characterize evolution of weak shock waves in air and to calibrate broadband acoustical microphones.
NASA Astrophysics Data System (ADS)
Song, Ai-Ling; Chen, Tian-Ning; Wang, Xiao-Peng; Wan, Le-Le
2016-08-01
The waveform distortion happens in most of the unidirectional acoustic transmission (UAT) devices proposed before. In this paper, a novel type of waveform-preserved UAT device composed of an impedance-matched acoustic metasurface (AMS) and a phononic crystal (PC) structure is proposed and numerically investigated. The acoustic pressure field distributions and transmittance are calculated by using the finite element method. The subwavelength AMS that can modulate the wavefront of the transmitted wave at will is designed and the band structure of the PC structure is calculated and analyzed. The sound pressure field distributions demonstrate that the unidirectional acoustic transmission can be realized by the proposed UAT device without changing the waveforms of the output waves, which is the distinctive feature compared with the previous UAT devices. The physical mechanism of the unidirectional acoustic transmission is discussed by analyzing the refraction angle changes and partial band gap map. The calculated transmission spectra show that the UAT device is valid within a relatively broad frequency range. The simulation results agree well with the theoretical predictions. The proposed UAT device provides a good reference for designing waveform-preserved UAT devices and has potential applications in many fields, such as medical ultrasound, acoustic rectifiers, and noise insulation.
Acute Heart Failure Triggered by Coronary Spasm With Transient Left Ventricular Dysfunction.
Adachi, Yusuke; Sakakura, Kenichi; Ibe, Tatsuro; Yoshida, Nanae; Wada, Hiroshi; Fujita, Hideo; Momomura, Shin-Ichi
2017-04-06
Coronary spasm is abnormal contraction of an epicardial coronary artery resulting in myocardial ischemia. Coronary spasm induces not only depressed myocardial contractility, but also incomplete myocardial relaxation, which leads to elevated ventricular filling pressure. We herein report the case of a 55-year-old woman who had repeated acute heart failure caused by coronary spasm. Acetylcholine provocation test with simultaneous right heart catheterization was useful for the diagnosis of elevated ventricular filling pressure as well as coronary artery spasm. We should add coronary spasm to a differential diagnosis for repeated acute heart failure.
Major new developments affecting treatment and prognosis in hypertension.
Gubner, R S
1990-01-01
Joint studies of the ALIMDA and Society of Actuaries, notably those of 1935, 1959 and 1979, established that there is a progressive rise in cardiovascular mortality with successive increments in blood pressure. This has provided the basis of underwriting. The converse is not true, or at least has not been true until very recently. Drugs that effectively reduce blood pressure have been available for several decades, but reduction and maintenance of blood pressure is still accomplished in only a minority of hypertensives. Long-term trials employing a combination of drugs, i.e., diuretics, vasodilators and reserpine and subsequently beta-blockers, almost without fail have not shown that treatment with these agents significantly reduces heart disease mortality and sudden death. This has been attributed, perhaps without basis, to an unfavorable countering effect of increased lipid levels, aggravating this risk factor, and other undesirable metabolic effect of diuretics, such as hypokalemia and depletion of body magnesium, increasing the propensity to ventricular arrhythmias, hyperglycemia, worsening diabetes, and hyperuricemia. A survey of 674 persons with hypertension seen personally during the period 1985-89, who were under the care of approximately that many physicians, reveals striking changes in drug prescription and use during this brief period that portend a major change in the outlook of hypertension. Two classes of drugs have increased rapidly in popularity: these are the angiotensin-converting enzyme inhibitors (ACE inhibitors) and the calcium blockers. Both classes of drugs effectively lower blood pressure and have minimal side effects with good compliance. They act not only to reduce peripheral vascular resistance, but also locally in the heart muscle to directly cause left ventricular hypertrophy to regress, an effect of great consequence. The drugs used in former trials such as the vasodilators and diuretics have no effect on left ventricular hypertrophy, unlike the ACE inhibitors and calcium antagonists. Left ventricular hypertrophy is the key lesion in hypertension and is only in part due to increased work load imposed by elevated pressure. It is associated with elevated blood pressure, but not closely and occurs independently; ventricular myocytes as well as myocytes of the vasculature being stimulated to growth by angiotensin and calcium, potentiating the effect of norepinephrine. Left ventricular hypertrophy greatly increases the propensity to ventricular arrhythmias and sudden death, and is a prime cause of cardiac mortality and sudden death not only in hypertension, but also in obesity, aging and diabetes, in which conditions left ventricular hypertrophy also is very common.(ABSTRACT TRUNCATED AT 400 WORDS)
Dangers of collapsible ventricular drainage systems. Technical note.
Kaye, A H; Wallace, D
1982-02-01
Ventricular drainage systems employing a collapsible plastic bag for fluid collection were postulated to cause an increasing back-pressure produced in part by the elasticity of the bag. This postulate was shown to be correct in an experimental situation. There was a logarithmic rise in cerebrospinal fluid pressure as the bag filled. By increasing the size of the bag, the problem was overcome.
ERIC Educational Resources Information Center
Gokhan, Ismail; Kurkcu, Recep; Cekin, Resul
2013-01-01
In this study, it was aimed to compare the investigate the effects of regular exercise on blood lipids, blood pressure and left ventricular cavity dimensions function between soccer players and non-athletes in football players. This study consisted included a total of 30 subjects, including an experimental group including 18 soccer players…
The leaking mode problem in atmospheric acoustic-gravity wave propagation
NASA Technical Reports Server (NTRS)
Kinney, W. A.; Pierce, A. D.
1976-01-01
The problem of predicting the transient acoustic pressure pulse at long horizontal distances from large explosions in the atmosphere is examined. Account is taken of poles off the real axis and of branch line integrals in the general integral governing the transient waveform. Perturbation techniques are described for the computation of the imaginary ordinate of the poles and numerical studies are described for a model atmosphere terminated by a halfspace with c = 478 m/sec above 125 km. For frequencies less than 0.0125 rad/sec, the GR sub 1 mode, for example, is found to have a frequency dependent amplitude decay of the order of 0.0001 nepers/km. Examples of numerically synthesized transient waveforms are exhibited with and without the inclusion of leaking modes. The inclusion of leaking modes results in waveforms with a more marked beginning rather than a low frequency oscillating precursor of gradually increasing amplitude. Also, the revised computations indicate that waveforms invariably begin with a pressure rise, a result supported by other theoretical considerations and by experimental data.
Bajraktari, Gani; Berbatovci-Ukimeraj, Mimoza; Hajdari, Ali; Ibraimi, Lavdim; Daullxhiu, Irfan; Elezi, Ymer; Ndrepepa, Gjin
2009-01-01
Aim To study the left and right ventricular function and to assess the predictors of increased left ventricular (LV) filling pressure in dialysis patients with preserved LV ejection fraction. Methods This study included 63 consecutive patients (age 57 ± 14 years, 57% women) with end-stage renal failure. Echocardiography, including tissue Doppler measurements, was performed in all patients. Based on the median value of the ratio of transmitral early diastolic velocity to early myocardial velocity (E/E’ ratio), patients were divided into 2 groups: the group with high filling pressure (E/E’>10.16) and the group with low filling pressure (E/E’≤10.16). Results Compared with patients with low filling pressure, the group of patients with high filling pressure included a higher proportion of diabetic patients (41% vs 13%, P = 0.022) and had greater LV mass index (211 ± 77 vs 172 ± 71 g/m3, P = 0.04), lower LV lateral long axis amplitude (1.4 ± 0.3 vs 1.6 ± 0.3 cm, P = 0.01), higher E wave (84 ± 19 vs 64 ± 18cm/s, P < 0.001), lower systolic myocardial velocity (S’:8.6 ± 1.5 vs 7.0 ± 1.3 cm/s, P < 0.001), and lower diastolic myocardial velocities (E’: 6.3 ± 1.9 vs 9.5 ± 2.9 cm/s, P < 0.001; A’: 8.4 ± 1.9 vs 9.7 ± 2.5 cm/s, P = 0.018). Multivariate analysis identified LV systolic myocardial velocity – S’ wave (adjusted odds ratio, 1.909; 95% confidence interval, 1.060-3.439; P = 0.031) and age (1.053; 1.001-1.108; P = 0.048) as the only independent predictors of high LV filling pressure in dialysis patients. Conclusions In dialysis patients with preserved left ventricular ejection fraction, reduced systolic myocardial velocity and elderly age are independent predictors of increased left ventricular filling pressure. PMID:20017222
Maggi, Roberto; Viscardi, Valentina; Furukawa, Toshiyuki; Brignole, Michele
2010-01-01
Aims We thought to evaluate feasibility of continuous non-invasive blood pressure monitoring during procedures of interventional electrophysiology. Methods and results We evaluated continuous non-invasive finger blood pressure (BP) monitoring by means of the Nexfin device in 22 patients (mean age 70 ± 24 years), undergoing procedures of interventional electrophysiology, in critical situations of hypotension caused by tachyarrhythmias or by intermittent incremental ventricular temporary pacing till to the maximum tolerated systolic BP fall (mean 61 ± 14 mmHg per patient at a rate of 195 ± 37 bpm). In all patients, Nexfin was able to detect immediately, at the onset of tachyarrythmia, the changes in BP and recorded reliable waveforms. The quality of the signal was arbitrarily classified as excellent in 11 cases, good in 10 cases, and sufficient in 1 case. In basal conditions, calibrations of the signal occurred every 49.2 ± 24.3 s and accounted for 4% of total monitoring time; during tachyarrhythmias their frequency increased to one every 12.7 s and accounted for 19% of total recording duration. A linear correlation for a range of BP values from 41 to 190 mmHg was found between non-invasive and intra-arterial BP among a total of 1055 beats from three patients who underwent simultaneous recordings with both methods (coefficient of correlation of 0.81, P < 0.0001). Conclusion In conclusion, continuous non-invasive BP monitoring is feasible in the clinical practise of an interventional electrophysiology laboratory without the need of utilization of an intra-arterial BP line. PMID:20837572
Computer program for analysis of hemodynamic response to head-up tilt test
NASA Astrophysics Data System (ADS)
ŚwiÄ tek, Eliza; Cybulski, Gerard; Koźluk, Edward; PiÄ tkowska, Agnieszka; Niewiadomski, Wiktor
2014-11-01
The aim of this work was to create a computer program, written in the MATLAB environment, which enables the visualization and analysis of hemodynamic parameters recorded during a passive tilt test using the CNS Task Force Monitor System. The application was created to help in the assessment of the relationship between the values and dynamics of changes of the selected parameters and the risk of orthostatic syncope. The signal analysis included: R-R intervals (RRI), heart rate (HR), systolic blood pressure (sBP), diastolic blood pressure (dBP), mean blood pressure (mBP), stroke volume (SV), stroke index (SI), cardiac output (CO), cardiac index (CI), total peripheral resistance (TPR), total peripheral resistance index (TPRI), ventricular ejection time (LVET) and thoracic fluid content (TFC). The program enables the user to visualize waveforms for a selected parameter and to perform smoothing with selected moving average parameters. It allows one to construct the graph of means for any range, and the Poincare plot for a selected time range. The program automatically determines the average value of the parameter before tilt, its minimum and maximum value immediately after changing positions and the times of their occurrence. It is possible to correct the automatically detected points manually. For the RR interval, it determines the acceleration index (AI) and the brake index (BI). It is possible to save calculated values to an XLS with a name specified by user. The application has a user-friendly graphical interface and can run on a computer that has no MATLAB software.
Bombardini, Tonino; Mulieri, Louis A; Salvadori, Stefano; Costantino, Marco Fabio; Scali, Maria Chiara; Marzilli, Mario; Picano, Eugenio
2017-02-01
The variation between rest and peak stress end-systolic pressure-volume relation is an afterload-independent index of left ventricular contractility. Whether and to what extent it depends on end-diastolic volume remains unclear. The aim of this study was to assess the dependence of the delta rest-stress end-systolic pressure-volume relation on end-diastolic volume in patients with negative stress echo and all ranges of resting left ventricular function. We analyzed interpretable data obtained in 891 patients (593 men, age 63 ± 12 years) with ejection fraction 47% ± 12%: 338 were normal or near-normal or hypertensive; 229 patients had coronary artery disease; and 324 patients had ischemic or nonischemic dilated cardiomyopathy. They were studied with exercise (n = 172), dipyridamole (n = 482) or dobutamine (n = 237) stress echocardiography. The end-systolic pressure-volume relation was evaluated at rest and peak stress from raw measurement of systolic arterial pressure by cuff sphygmomanometer and end-systolic volume by biplane Simpson rule 2-dimensional echocardiography. Absolute values of delta rest-stress end-systolic pressure-volume relation were higher for exercise and dobutamine than for dipyridamole. In the overall population, an inverse relationship between end-systolic pressure-volume relation and end-diastolic volume was present at rest (r 2 = 0.69, P < .001) and peak stress (r 2 = 0.56, P < .001), but was absent if the delta rest-stress end-systolic pressure-volume relation was considered (r 2 = 0.13). Left ventricular end-diastolic volume does not affect the rest-stress changes in end-systolic pressure-volume relation in either normal or abnormal left ventricles during physical or pharmacological stress. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Three-Dimensional Echocardiography-Derived Non-Invasive Right Ventricular Pressure-Volume Analysis.
Huang, Kuan-Chih; Lin, Lian-Yu; Hwang, Juey-Jen; Lin, Lung-Chun
2017-09-01
In patients with pulmonary hypertension, repeated evaluations of right ventricular (RV) function are still required for clinical decision making, but the invasive nature of current pressure-volume analysis makes conducting regular follow-ups in a clinical setting infeasible. We enrolled 12 patients with pulmonary arterial hypertension (PAH) and 10 with pulmonary venous hypertension (PVH) May 2016-October 2016. All patients underwent a clinically indicated right heart catheterization (RHC), from which the yielded right ventricular pressure recordings were conjugated with RV volume by 3-D echocardiography to generate a pressure-volume loop. A continuous-wave Doppler envelope of tricuspid regurgitation was transformed into a pressure gradient recording by the simplified Bernoulli equation, and then a systolic pressure gradient-volume (PG-V) diagram was generated from similar methods. The area enclosed by the pressure-volume loop was calculated to represent semi-invasive right ventricular stroke work (RVSW RHC ). The area between the PG-V diagram and x-axis was calculated to estimate non-invasive RVSW (RVSW echo ). Patients with PAH have higher RV pressure, lower pulmonary arterial wedge pressure and larger RV volume that was contributed by the dilation of RV mid-cavity minor dimension. We found no significant difference of traditional parameters between these two groups, but RVSW values were significantly higher in PAH patients. The RVSW values of these two methods were significantly correlated by the equation RVSW echo = 0.8447 RVSW RHC + 129.38 (R 2 = 0.9151, p < 0.001). The linearity remained satisfactory in both groups. We conclude that a PG-V diagram is a reliable method to estimate RVSW and to depict pathophysiological status. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Bouwmeester, J Christopher; Belenkie, Israel; Shrive, Nigel G; Tyberg, John V
2014-01-01
Conventional haemodynamic analysis of pulmonary venous and left atrial (LA) pressure waveforms yields substantial forward and backward waves throughout the cardiac cycle; the reservoir wave model provides an alternative analysis with minimal waves during diastole. Pressure and flow in a single pulmonary vein (PV) and the main pulmonary artery (PA) were measured in anaesthetized dogs and the effects of hypoxia and nitric oxide, volume loading, and positive-end expiratory pressure (PEEP) were observed. The reservoir wave model was used to determine the reservoir contribution to PV pressure and flow. Subtracting reservoir pressure and flow resulted in ‘excess’ quantities which were treated as wave-related. Wave intensity analysis of excess pressure and flow quantified the contributions of waves originating upstream (from the PA) and downstream (from the LA and/or left ventricle (LV)). Major features of the characteristic PV waveform are caused by sequential LA and LV contraction and relaxation creating backward compression (i.e. pressure-increasing) waves followed by decompression (i.e. pressure-decreasing) waves. Mitral valve opening is linked to a backwards decompression wave (i.e. diastolic suction). During late systole and early diastole, forward waves originating in the PA are significant. These waves were attenuated less with volume loading and delayed with PEEP. The reservoir wave model shows that the forward and backward waves are negligible during LV diastasis and that the changes in pressure and flow can be accounted for by the discharge of upstream reservoirs. In sharp contrast, conventional analysis posits forward and backward waves such that much of the energy of the forward wave is opposed by the backward wave. PMID:25015922
Measurement and Modeling of Acoustic Fields in a Gel Phantom at High Intensities
NASA Astrophysics Data System (ADS)
Canney, Michael S.; Bailey, Michael R.; Khokhlova, Vera A.; Crum, Lawrence A.
2006-05-01
The goal of this work was to compare measured and numerically predicted HIFU pressure waveforms in water and a tissue-mimicking phantom. Waveforms were measured at the focus of a 2-MHz HIFU transducer with a fiber optic hydrophone. The transducer was operated with acoustic powers ranging from 2W to 300W. A KZK-type equation was used for modeling the experimental conditions. Strongly asymmetric nonlinear waves with peak positive pressure up to 80 MPa and peak negative pressure up to 20 MPa were measured in water, while waves up to 50 MPa peak positive pressure and 15 MPa peak negative pressure were measured in tissue phantoms. The values of peak negative pressure corresponded well with numerical simulations and were significantly smaller than predicted by linear extrapolation from low-level measurements. The values of peak positive pressures differed only at high levels of excitation where bandwidth limitations of the hydrophone failed to fully capture the predicted sharp shock fronts.
Impact of Pulmonary Flow Study Pressure on Outcomes After One-Stage Unifocalization.
Trezzi, Matteo; Albanese, Sonia B; Albano, Antonio; Rinelli, Gabriele; D'Anna, Carolina; Polito, Angelo; Cetrano, Enrico; Carotti, Adriano
2017-12-01
The purpose of this study was to evaluate the accuracy of the pulmonary flow study in (1) predicting the feasibility of concomitant intracardiac repair after one-stage unifocalization; and in (2) predicting long-term survival and the onset of right ventricular dysfunction after surgery. Between October 1996 and July 2015, a flow study was obtained in 95 patients undergoing complete one-stage unifocalization for pulmonary atresia with ventricular septal defect and major aortopulmonary collaterals. The ability to achieve 100% flow (approximately 2.5 L · min -1 · m -2 ) into the pulmonary bed at a mean pressure of 30 mm Hg or less was utilized as an indicator for acceptability of ventricular septal defect closure. Overall survival was 78% ± 6% at 15 years. Sixty-four patients underwent successful one-stage intracardiac repair. The flow study accurately predicted suitability for VSD closure (area under the curve = 0.855). After one-stage ventricular septal defect closure, no difference in survival was observed after stratification according to flow study pressures (25 mm Hg or less versus greater than 25 mm Hg, log rank p = 0.20). At a median follow-up of 7 years, no association was found between flow study pressure and the onset of right ventricular dysfunction (p = 0.21). Overall, the inability to achieve final intracardiac repair was a strong predictor of death (hazard ratio 9.14, 95% confidence interval: 1.98 to 42.07, p < 0.0001). Suitability for ventricular septal defect closure is reliably defined by the flow study with a cutoff of 30 mm Hg. Flow study pressure values do not affect long-term outcomes. The ability to obtain intracardiac repair (in either one or more stages) is the strongest predictor of survival. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
A rabbit model of progressive chronic right ventricular pressure overload.
Roldan Ramos, Sara; Pieles, Guido; Hui, Wei; Slorach, Cameron; Redington, Andrew N; Friedberg, Mark K
2018-04-01
Right ventricular (RV) failure from increased pressure loading is a frequent consequence of acquired and congenital heart diseases. However, the mechanisms involved in their pathophysiology are still unclear, and few data exist on RV pressure-loading models and early versus late effects on RV and left ventricular responses. We characterized a rabbit model of chronic RV pressure overload and early-late effects on biventricular function. Twenty-one New Zealand white rabbits were randomized into 3 groups: (i) sham, (ii) pulmonary artery (PA) banding (PAB) for 3 weeks (PAB3W) and (iii) PAB for 6 weeks (PAB6W). Progressive RV pressure overload was created by serial band inflation using an adjustable device. Molecular, echocardiographic and haemodynamic studies were performed. RV pressure overload was achieved with clinical manifestations of RV failure. Heart and liver weights were significantly higher after PAB. PAB-induced echocardiographic ventricular remodelling increased wall thickness and stress and ventricular dilation. Cardiac output (ml/min) (sham 172.4 ± 42.86 vs PAB3W 103.1 ± 23.14 vs PAB6W 144 ± 60.9, P = 0.0027) and systolic and diastolic functions decreased; with increased RV end-systolic and end-diastolic pressures (mmHg) (sham 1.6 ± 0.66 vs PAB3W 3.9 ± 1.8 vs PAB6W 5.2 ± 2.2, P = 0.0103), despite increased contractility [end-systolic pressure-volume relationship (mmHg/ml), sham 3.76 ± 1.76 vs PAB3W 12.21 ± 3.44 vs PAB6W 19.4 ± 6.88, P < 0.0001]. Functional parameters further worsened after PAB6W versus PAB3W. LV contractility increased in both the PAB groups, despite worsening of other invasive measures of systolic and diastolic functions. We describe a novel, unique model of chronic RV pressure overload leading to early biventricular dysfunction and fibrosis with further progression at 6 weeks. These findings can aid in guiding management.
Haemers, Peter; Sutherland, George; Cikes, Maja; Jakus, Nina; Holemans, Patricia; Sipido, Karin R; Willems, Rik; Claus, Piet
2015-11-01
An acute increase in blood pressure is associated with the occurrence of premature ventricular complexes (PVCs). We aimed to study the timing of these PVCs with respect to afterload-induced changes in myocardial deformation in a controlled, preclinically relevant, novel closed-chest pig model. An acute left ventricular (LV) afterload challenge was induced by partial balloon inflation in the descending aorta, lasting 5-10 heartbeats (8 pigs; 396 inflations). Balloon inflation enhanced the reflected wave (augmentation index 30% ± 8% vs 59% ± 6%; P < .001), increasing systolic central blood pressure by 35% ± 4%. This challenge resulted in a more abrupt LV pressure decline, which was delayed beyond ventricular repolarization (rate of pressure decline 0.16 ± 0.01 mm Hg/s vs 0.27 ± 0.04 mm Hg/ms; P < .001 and interval T-wave to peak pressure 1 ± 12 ms vs 36 ± 9 ms; P = .008), during which the velocity of myocardial shortening at the basal septum increased abruptly (ie, postsystolic shortening) (peak strain rate -0.6 ± 0.5 s(-1) vs -2.5 ± 0.8 s(-1); P < .001). It is exactly at this time of LV pressure decline, with increased postsystolic shortening, and not at peak pressure, that PVCs occur (22% of inflations). These PVCs preferentially occurred at the basal and apical segments. In the same regions, monophasic action potentials demonstrated the appearance of delayed afterdepolarization-like transient depolarizations as origin of PVCs. An acute blood pressure increase results in a more abrupt LV pressure decline, which is delayed after ventricular repolarization. This has a profound effect on myocardial mechanics with enhanced postsystolic shortening. Coincidence with induced transient depolarizations and PVCs provides support for the mechanoelectrical origin of pressure-induced premature beats. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Modeling Nonlinear Acoustic Standing Waves in Resonators: Theory and Experiments
NASA Technical Reports Server (NTRS)
Raman, Ganesh; Li, Xiaofan; Finkbeiner, Joshua
2004-01-01
The overall goal of the cooperative research with NASA Glenn is to fundamentally understand, computationally model, and experimentally validate non-linear acoustic waves in enclosures with the ultimate goal of developing a non-contact acoustic seal. The longer term goal is to transition the Glenn acoustic seal innovation to a prototype sealing device. Lucas and coworkers are credited with pioneering work in Resonant Macrosonic Synthesis (RMS). Several Patents and publications have successfully illustrated the concept of Resonant Macrosonic Synthesis. To utilize this concept in practical application one needs to have an understanding of the details of the phenomenon and a predictive tool that can examine the waveforms produced within resonators of complex shapes. With appropriately shaped resonators one can produce un-shocked waveforms of high amplitude that would result in very high pressures in certain regions. Our goal is to control the waveforms and exploit the high pressures to produce an acoustic seal. Note that shock formation critically limits peak-to-peak pressure amplitudes and also causes excessive energy dissipation. Proper shaping of the resonator is thus critical to the use of this innovation.
Axell, Richard G; Giblett, Joel P; White, Paul A; Klein, Andrew; Hampton-Til, James; O'Sullivan, Michael; Braganza, Denise; Davies, William R; West, Nick E J; Densem, Cameron G; Hoole, Stephen P
2017-06-06
We sought to determine whether right ventricular stunning could be detected after supply (during coronary balloon occlusion [BO]) and supply/demand ischemia (induced by rapid pacing [RP] during transcatheter aortic valve replacement) in humans. Ten subjects with single-vessel right coronary artery disease undergoing percutaneous coronary intervention with normal ventricular function were studied in the BO group. Ten subjects undergoing transfemoral transcatheter aortic valve replacement were studied in the RP group. In both, a conductance catheter was placed into the right ventricle, and pressure volume loops were recorded at baseline and for intervals over 15 minutes after a low-pressure BO for 1 minute or a cumulative duration of RP for up to 1 minute. Ischemia-induced diastolic dysfunction was seen 1 minute after RP (end-diastolic pressure [mm Hg]: 8.1±4.2 versus 12.1±4.1, P <0.001) and BO (end-diastolic pressure [mm Hg]: 8.1 ± 4.0 versus 8.7±4.0, P =0.03). Impairment of systolic and diastolic function after BO remained at 15-minutes recovery (ejection fraction [%]: 55.7±9.0 versus 47.8±6.3, P <0.01; end-diastolic pressure [mm Hg]: 8.1±4.0 versus 9.2±3.9, P <0.01). Persistent diastolic dysfunction was also evident in the RP group at 15-minutes recovery (end-diastolic pressure [mm Hg]: 8.1±4.1 versus 9.9±4.4, P =0.03) and there was also sustained impairment of load-independent indices of systolic function at 15 minutes after RP (end-systolic elastance and ventriculo-arterial coupling [mm Hg/mL]: 1.25±0.31 versus 0.85±0.43, P <0.01). RP and right coronary artery balloon occlusion both cause ischemic right ventricular dysfunction with stunning observed later during the procedure. This may have intraoperative implications in patients without right ventricular functional reserve. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Sack, Kevin L; Dabiri, Yaghoub; Franz, Thomas; Solomon, Scott D; Burkhoff, Daniel; Guccione, Julius M
2018-01-01
Predictive computation models offer the potential to uncover the mechanisms of treatments whose actions cannot be easily determined by experimental or imaging techniques. This is particularly relevant for investigating left ventricular mechanical assistance, a therapy for end-stage heart failure, which is increasingly used as more than just a bridge-to-transplant therapy. The high incidence of right ventricular failure following left ventricular assistance reflects an undesired consequence of treatment, which has been hypothesized to be related to the mechanical interdependence between the two ventricles. To investigate the implication of this interdependence specifically in the setting of left ventricular assistance device (LVAD) support, we introduce a patient-specific finite-element model of dilated chronic heart failure. The model geometry and material parameters were calibrated using patient-specific clinical data, producing a mechanical surrogate of the failing in vivo heart that models its dynamic strain and stress throughout the cardiac cycle. The model of the heart was coupled to lumped-parameter circulatory systems to simulate realistic ventricular loading conditions. Finally, the impact of ventricular assistance was investigated by incorporating a pump with pressure-flow characteristics of an LVAD (HeartMate II™ operating between 8 and 12 k RPM) in parallel to the left ventricle. This allowed us to investigate the mechanical impact of acute left ventricular assistance at multiple operating-speeds on right ventricular mechanics and septal wall motion. Our findings show that left ventricular assistance reduces myofiber stress in the left ventricle and, to a lesser extent, right ventricle free wall, while increasing leftward septal-shift with increased operating-speeds. These effects were achieved with secondary, potentially negative effects on the interventricular septum which showed that support from LVADs, introduces unnatural bending of the septum and with it, increased localized stress regions. Left ventricular assistance unloads the left ventricle significantly and shifts the right ventricular pressure-volume-loop toward larger volumes and higher pressures; a consequence of left-to-right ventricular interactions and a leftward septal shift. The methods and results described in the present study are a meaningful advancement of computational efforts to investigate heart-failure therapies in silico and illustrate the potential of computational models to aid understanding of complex mechanical and hemodynamic effects of new therapies.
Complexity of intracranial pressure correlates with outcome after traumatic brain injury
Lu, Cheng-Wei; Czosnyka, Marek; Shieh, Jiann-Shing; Smielewska, Anna; Pickard, John D.
2012-01-01
This study applied multiscale entropy analysis to investigate the correlation between the complexity of intracranial pressure waveform and outcome after traumatic brain injury. Intracranial pressure and arterial blood pressure waveforms were low-pass filtered to remove the respiratory and pulse components and then processed using a multiscale entropy algorithm to produce a complexity index. We identified significant differences across groups classified by the Glasgow Outcome Scale in intracranial pressure, pressure-reactivity index and complexity index of intracranial pressure (P < 0.0001; P = 0.001; P < 0.0001, respectively). Outcome was dichotomized as survival/death and also as favourable/unfavourable. The complexity index of intracranial pressure achieved the strongest statistical significance (F = 28.7; P < 0.0001 and F = 17.21; P < 0.0001, respectively) and was identified as a significant independent predictor of mortality and favourable outcome in a multivariable logistic regression model (P < 0.0001). The results of this study suggest that complexity of intracranial pressure assessed by multiscale entropy was significantly associated with outcome in patients with brain injury. PMID:22734128
Wink, Jeroen; de Wilde, Rob B P; Wouters, Patrick F; van Dorp, Eveline L A; Veering, Bernadette Th; Versteegh, Michel I M; Aarts, Leon P H J; Steendijk, Paul
2016-10-18
Blockade of cardiac sympathetic fibers by thoracic epidural anesthesia may affect right ventricular function and interfere with the coupling between right ventricular function and right ventricular afterload. Our main objectives were to study the effects of thoracic epidural anesthesia on right ventricular function and ventricular-pulmonary coupling. In 10 patients scheduled for lung resection, right ventricular function and its response to increased afterload, induced by temporary, unilateral clamping of the pulmonary artery, was tested before and after induction of thoracic epidural anesthesia using combined pressure-conductance catheters. Thoracic epidural anesthesia resulted in a significant decrease in right ventricular contractility (ΔESV 25 : +25.5 mL, P=0.0003; ΔEes: -0.025 mm Hg/mL, P=0.04). Stroke work, dP/dt MAX , and ejection fraction showed a similar decrease in systolic function (all P<0.05). A concomitant decrease in effective arterial elastance (ΔEa: -0.094 mm Hg/mL, P=0.004) yielded unchanged ventricular-pulmonary coupling. Cardiac output, systemic vascular resistance, and mean arterial blood pressure were unchanged. Clamping of the pulmonary artery significantly increased afterload (ΔEa: +0.226 mm Hg/mL, P<0.001). In response, right ventricular contractility increased (ΔESV 25 : -26.6 mL, P=0.0002; ΔEes: +0.034 mm Hg/mL, P=0.008), but ventricular-pulmonary coupling decreased (Δ(Ees/Ea) = -0.153, P<0.0001). None of the measured indices showed significant interactive effects, indicating that the effects of increased afterload were the same before and after thoracic epidural anesthesia. Thoracic epidural anesthesia impairs right ventricular contractility but does not inhibit the native positive inotropic response of the right ventricle to increased afterload. Right ventricular-pulmonary arterial coupling was decreased with increased afterload but not affected by the induction of thoracic epidural anesthesia. URL: http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2844. Unique identifier: NTR2844. © 2016 American Heart Association, Inc.
Moore, Dana W.; Kovanlikaya, Ilhami; Heier, Linda A.; Raj, Ashish; Huang, Chaorui; Chu, King-Wai; Relkin, Norman R.
2012-01-01
Current radiologic diagnosis of normal pressure hydrocephalus (NPH) requires a subjective judgment of whether lateral ventricular enlargement is disproportionate to cerebral atrophy based on visual inspection of brain images. We investigated whether quantitative measurements of lateral ventricular volume and total cortical thickness (a correlate of cerebral atrophy) could be used to more objectively distinguish NPH from normal controls (NC), Alzheimer's (AD), and Parkinson's disease (PD). Volumetric MRIs were obtained prospectively from patients with NPH (n = 5), PD (n = 5), and NC (5). Additional NC (n = 5) and AD patients (n = 10) from the ADNI cohort were examined. Although mean ventricular volume was significantly greater in the NPH group than all others, the range of values overlapped those of the AD group. Individuals with NPH could be better distinguished when ventricular volume and total cortical thickness were considered in combination. This pilot study suggests that volumetric MRI measurements hold promise for improving NPH differential diagnosis. PMID:21860791
Pulsed Phase Lock Loop Device for Monitoring Intracranial Pressure During Space Flight
NASA Technical Reports Server (NTRS)
Ueno, Toshiaki; Macias, Brandon R.; Yost, William T.; Hargens, Alan R.
2003-01-01
We have developed an ultrasonic device to monitor ICP waveforms non-invasively from cranial diameter oscillations using a NASA-developed pulsed phase lock loop (PPLL) technique. The purpose of this study was to attempt to validate the PPLL device for reliable recordings of ICP waveforms and analysis of ICP dynamics in vivo. METHODS: PPLL outputs were recorded in patients during invasive ICP monitoring at UCSD Medical Center (n=10). RESULTS: An averaged linear regression coefficient between ICP and PPLL waveform data during one cardiac cycle in all patients is 0.88 +/- 0.02 (mean +/- SE). Coherence function analysis indicated that ICP and PPLL waveforms have high correlation in the lst, 2nd, and 3rd harmonic waves associated with a cardiac cycle. CONCLUSIONS: PPLL outputs represent ICP waveforms in both frequency and time domains. PPLL technology enables in vivo evaluation of ICP dynamics non-invasively, and can acquire continuous ICP waveforms during spaceflight because of compactness and non-invasive nature.
Krams, R; Sipkema, P; Westerhof, N
1990-06-01
In this study on the isolated, maximally vasodilated, blood-perfused cat heart we investigated the relation between left ventricular developed pressure (delta Piv) and coronary oscillatory flow amplitude (diastolic minus systolic flow, delta F) at different levels of constant perfusion pressure (Pp). We hypothesized that the effect of cardiac contraction on the phasic flow results from the changing elastic properties of cardiac muscle. The coronary vessel compartment can, as can the left ventricular lumen compartment, be described by a time-varying elastance. This concept predicts that the effect of left ventricular pressure on delta F is small, whereas the effect of Pp is considerable. Both the waterfall model and the intramyocardial pump model predict the inverse. The relation between delta Piv and delta F at a Pp of 10 kPa is delta F = (4.71 +/- 3.08).delta Piv + 337 +/- 75 (slope in ml.min-1.100 g-1.kPa-1 and intercept in ml.min-1.100 g-1; n = 7); the relation between (constant levels of) Pp and delta F at a constant delta Piv of 10 kPa is delta F = 51.Pp + 211 (slope in ml.min-1.100 g-1.kPa-1 and intercept in ml.min-1.100 g-1; n = 6). The differences in slope are best predicted by the time-varying elastance concept.
Marks, J D; Pantalos, G M; Long, J W; Kinoshita, M; Everett, S D; Olsen, D B
1999-01-01
Unlike the mechanisms of intraaortic balloon pump (IABP) support, the mechanisms by which transvalvular axial flow Hemopump (HP) support benefit dysfunctional myocardium are less clearly understood. To help elucidate these mechanisms, hemodynamic, metabolic, and mechanical indexes of left ventricular function were measured during conditions of control, ischemic dysfunction, IABP support, and HP support. A large animal (calf) model of left ventricular dysfunction was created with multiple coronary ligations. Peak intraventricular pressure increased with HP support and decreased with IABP support. Intramyocardial pressure (an indicator of intramyocardial stress), time rate of pressure change (an indicator of contractility), and left ventricular myocardial oxygen consumption decreased with IABP and HP support. Left ventricular work decreased with HP support and increased with IABP support. During HP support, indexes of wall stress, work, and contractility, all primary determinants of oxygen consumption, were reduced. During IABP support, indexes of wall stress and contractility were reduced and external work increased. These changes were attributed primarily to changes in ventricular preload, and geometry for HP support, and to a reduction in afterload for IABP support. These findings support the hypothesis that both HP and IABP support reduce intramyocardial stress development and the corresponding oxygen consumption, although via different mechanisms.
Ma, Hongyue; Zhang, Junfeng; Jiang, Jiejun; Zhou, Jing; Xu, Huiqin; Zhan, Zhen; Wu, Qinan; Duan, Jinao
2012-03-01
Bufadienolides, known ligands of the sodium pump, have been shown to inhibit the proliferation of several cancer cell types. However, their development to date as anticancer agents has been impaired by a narrow therapeutic margin resulting from their potential to induce cardiotoxicity. In the present study, we examined the effects of bilirubin, an endogenous antioxidant, on the cardiotoxicity of bufadienolides (derived from toad venom) in guinea-pigs. The results showed that bufadienolides (8 mg/kg) caused ventricular arrhythmias, conduction block, cardiac dysfunction and death in guinea-pigs. Pretreatment with bilirubin (75 and 150 mg/kg) significantly prevented bufadienolide-induced premature ventricular complexes, ventricular tachycardia, ventricular fibrillation and death. Bilirubin also markedly improved the inhibition of cardiac contraction in bufadienolide-treated guinea-pigs as evidenced by increases in left ventricular systolic pressure and decreases in left ventricular diastolic pressure in vivo. Furthermore, bilirubin significantly reduced the intracellular sodium content ([Na(+)]( i )) in ex vivo bufadienolide-stimulated guinea-pig ventricular myocytes loaded with the sodium indicator Sodium Green. An antitumor study showed that bilirubin did not compromise the ability of bufadienolides to inhibit gastric cancer cell MGC-803 proliferation. These results suggested that bilirubin can attenuate bufadienolide-induced arrhythmias and cardiac dysfunction in guinea-pigs by reducing elevated [Na(+)]( i ) and may improve bufadienolide therapeutic index in cancer treatment.
Jin, Cheng; Stein, Gregory J; Hong, Kyung-Han; Lin, C D
2015-07-24
We investigate the efficient generation of low-divergence high-order harmonics driven by waveform-optimized laser pulses in a gas-filled hollow waveguide. The drive waveform is obtained by synthesizing two-color laser pulses, optimized such that highest harmonic yields are emitted from each atom. Optimization of the gas pressure and waveguide configuration has enabled us to produce bright and spatially coherent harmonics extending from the extreme ultraviolet to soft x rays. Our study on the interplay among waveguide mode, atomic dispersion, and plasma effect uncovers how dynamic phase matching is accomplished and how an optimized waveform is maintained when optimal waveguide parameters (radius and length) and gas pressure are identified. Our analysis should help laboratory development in the generation of high-flux bright coherent soft x rays as tabletop light sources for applications.
NASA Technical Reports Server (NTRS)
Boettcher, D. H.; Vatner, S. F.; Heyndrickx, G. R.; Braunwald, E.
1978-01-01
The left ventricular end-diastolic pressure-dimension relationships in conscious dogs were studied; the ventricle was stressed to its limit in terms of myocardial preload in order to assess the extent of use of the Frank-Starling mechanism under these conditions. The preload was increased through volume loading with saline infusions, the provocation of global myocardial ischemia by constriction of the left main coronary artery, and infusion of methoxamine. While left ventricular end-diastolic pressure increased substantially in the reclining conscious animals, the left ventricular end-diastolic diameter did not increase, suggesting a minimum role for the Frank-Starling mechanism in this case.
Yamashita, H; Onodera, S; Imamoto, T; Obara, A; Tanazawa, S; Takashio, T; Morimoto, H; Inoue, H
1989-10-01
To clarify the effects of right ventricular (RV) pressure overload on functional and geometrical interference and interdependency between the right and left ventricle, both ventricular internal diameters were measured by the microcrystal technique during lycopodium induced pulmonary embolization in the dog. By repeated embolization, RV systolic pressure was increased progressively until it reached a peak value of about 60-70 mmHg, then it began to fall. At the same time, the hemodynamics deteriorated progressively resulting in death. During the experiment, gradual leftward displacement of the interventricular septum (IVS) without any change in left ventricular (LV) free wall geometry was observed. In pulmonary embolic shock, which showed a fall in LV pressure to about 60 mmHg and cardiac output to about 40% of control, the leftward displacement of IVS became marked, and the cooperative movement of IVS to LV contraction disappeared. The IVS position during acute RV pressure overload was able to account for the transseptal pressure gradient. The importance of IVS position and motion in cardiac function during acute RV pressure overload was stressed. Furthermore, to establish the theoretical treatment in acute cardiopulmonary resuscitation, ligation of the descending aorta (AoL) or norepinephrine ("N") or isoproterenol ("I") administration were examined in a canine pulmonary embolic shock model. AoL or "N" improved the deteriorated hemodynamics with restoration of biventricular geometry. However, "I" did not restore the biventricular geometry despite the transiently improved hemodynamics, and the experimental animals were unable to survive. These results suggest the importance of the maintainance of systemic pressure for the restoration of failed RV function. Further integrated studies are required to understand biventricular interference and interdependency.
Propionyl-L-carnitine limits chronic ventricular dilation after myocardial infarction in rats.
Micheletti, R; Di Paola, E D; Schiavone, A; English, E; Benatti, P; Capasso, J M; Anversa, P; Bianchi, G
1993-04-01
To determine whether propionyl-L-carnitine (PLC) administration ameliorates ventricular remodeling after myocardial infarction, we performed coronary occlusion in rats and examined the long-term effects of the drug 19-24 wk after surgery. In view of the well-established role of angiotensin-converting enzyme (ACE) inhibitors in the reduction of ventricular dilation after infarction, the therapeutic impact of oral PLC (60 mg/kg) was compared with that of enalapril (1 mg/kg). Infarct size measured planimetrically was found to be comparable in untreated, PLC-treated, and enalapril-treated rats, averaging 40-46% of the left ventricular free wall. Heart weight was increased 14, 16, and 11% with no treatment, with PLC, and with enalapril, respectively. The relationship between left ventricular filling pressure and chamber volume demonstrated that PLC and enalapril significantly prevented the expansion in cavitary size after infarction. These protective influences were observed throughout the range of filling pressures measured, from 0 to 30 mmHg. At a uniform reference point of filling pressure of 4 mmHg, untreated infarcted hearts showed an expansion in ventricular volume of 2.17-fold (P < 0.0001). Corresponding increases in this parameter after PLC and enalapril were 36 and 43%, respectively, both not statistically significant. Moreover, PLC was capable of reducing the alterations in myocardial compliance associated with myocardial infarction. In conclusion, PLC reduces the magnitude of decompensated eccentric hypertrophy produced by myocardial infarction in a manner similar to that found with ACE inhibition.
Unsteady blade-surface pressures on a large-scale advanced propeller: Prediction and data
NASA Technical Reports Server (NTRS)
Nallasamy, M.; Groeneweg, J. F.
1990-01-01
An unsteady 3-D Euler analysis technique is employed to compute the flow field of an advanced propeller operating at an angle of attack. The predicted blade pressure waveforms are compared with wind tunnel data at two Mach numbers, 0.5 and 0.2. The inflow angle is three degrees. For an inflow Mach number of 0.5, the predicted pressure response is in fair agreement with data: the predicted phases of the waveforms are in close agreement with data while the magnitudes are underpredicted. At the low Mach number of 0.2 (takeoff), the numerical solution shows the formation of a leading edge vortex which is in qualitative agreement with measurements. However, the highly nonlinear pressure response measured on the blade suction surface is not captured in the present inviscid analysis.
Unsteady blade surface pressures on a large-scale advanced propeller - Prediction and data
NASA Technical Reports Server (NTRS)
Nallasamy, M.; Groeneweg, J. F.
1990-01-01
An unsteady three dimensional Euler analysis technique is employed to compute the flowfield of an advanced propeller operating at an angle of attack. The predicted blade pressure waveforms are compared with wind tunnel data at two Mach numbers, 0.5 and 0.2. The inflow angle is three degrees. For an inflow Mach number of 0.5, the predicted pressure response is in fair agreement with data: the predicted phases of the waveforms are in close agreement with data while the magnitudes are underpredicted. At the low Mach number of 0.2 (take-off) the numerical solution shows the formation of a leading edge vortex which is in qualitative agreement with measurements. However, the highly nonlinear pressure response measured on the blade suction surface is not captured in the present inviscid analysis.
Patient characteristics associated with false arrhythmia alarms in intensive care
Harris, Patricia R; Zègre-Hemsey, Jessica K; Schindler, Daniel; Bai, Yong; Pelter, Michele M; Hu, Xiao
2017-01-01
Introduction A high rate of false arrhythmia alarms in the intensive care unit (ICU) leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. Objective The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. Methods This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds) at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and ventricular bradycardia) as true or false. Total monitoring time for each patient was measured, and the number of false alarms per hour was calculated for these six alarm types. Medical records were examined to acquire data on patient characteristics. Results A total of 461 unique patients (mean age =60±17 years) were enrolled, generating a total of 2,558,760 alarms, including all levels of arrhythmia, parameter, and technical alarms. There were 48,404 hours of patient monitoring time, and an average overall alarm rate of 52 alarms/hour. Investigators annotated 12,671 arrhythmia alarms; 11,345 (89.5%) were determined to be false. Two hundred and fifty patients (54%) generated at least one of the six annotated alarm types. Two patients generated 6,940 arrhythmia alarms (55%). The number of false alarms per monitored hour for patients’ annotated arrhythmia alarms ranged from 0.0 to 7.7, and the duration of these false alarms per hour ranged from 0.0 to 158.8 seconds. Patient characteristics were compared in relation to 1) the number and 2) the duration of false arrhythmia alarms per 24-hour period, using nonparametric statistics to minimize the influence of outliers. Among the significant associations were the following: age ≥60 years (P=0.013; P=0.034), confused mental status (P<0.001 for both comparisons), cardiovascular diagnoses (P<0.001 for both comparisons), electrocardiographic (ECG) features, such as wide ECG waveforms that correspond to ventricular depolarization known as QRS complex due to bundle branch block (BBB) (P=0.003; P=0.004) or ventricular paced rhythm (P=0.002 for both comparisons), respiratory diagnoses (P=0.004 for both comparisons), and support with mechanical ventilation, including those with primary diagnoses other than respiratory ones (P<0.001 for both comparisons). Conclusion Patients likely to trigger a higher number of false arrhythmia alarms may be those with older age, confusion, cardiovascular diagnoses, and ECG features that indicate BBB or ventricular pacing, respiratory diagnoses, and mechanical ventilatory support. Algorithm improvements could focus on better noise reduction (eg, motion artifact with confused state) and distinguishing BBB and paced rhythms from ventricular arrhythmias. Increasing awareness of patient conditions that apparently trigger a higher rate of false arrhythmia alarms may be useful for reducing unnecessary noise and improving alarm management. PMID:28458554
Baranowski, Jacek; Delshad, Baz; Ahn, Henrik
2017-01-01
After implantation of a continuous-flow left ventricular assist device (LVAD), left atrial pressure (LAP) monitoring allows for the precise management of intravascular volume, inotropic therapy, and pump speed. In this case series of 4 LVAD recipients, we report the first clinical use of this wireless pressure sensor for the long-term monitoring of LAP during LVAD support. A wireless microelectromechanical system pressure sensor (Titan, ISS Inc., Ypsilanti, MI) was placed in the left atrium in four patients at the time of LVAD implantation. Titan sensor LAP was measured in all four patients on the intensive care unit and in three patients at home. Ramped speed tests were performed using LAP and echocardiography in three patients. The left ventricular end-diastolic diameter (cm), flow (L/min), power consumption (W), and blood pressure (mm Hg) were measured at each step. Measurements were performed over 36, 84, 137, and 180 days, respectively. The three discharged patients had equipment at home and were able to perform daily recordings. There were significant correlations between sensor pressure and pump speed, LV and LA size and pulmonary capillary wedge pressure, respectively (r = 0.92–0.99, p < 0.05). There was no device failure, and there were no adverse consequences of its use. PMID:27676410
Fluid dynamics model of mitral valve flow: description with in vitro validation.
Thomas, J D; Weyman, A E
1989-01-01
A lumped variable fluid dynamics model of mitral valve blood flow is described that is applicable to both Doppler echocardiography and invasive hemodynamic measurement. Given left atrial and ventricular compliance, initial pressures and mitral valve impedance, the model predicts the time course of mitral flow and atrial and ventricular pressure. The predictions of this mathematic formulation have been tested in an in vitro analog of the left heart in which mitral valve area and atrial and ventricular compliance can be accurately controlled. For the situation of constant chamber compliance, transmitral gradient is predicted to decay as a parabolic curve, and this has been confirmed in the in vitro model with r greater than 0.99 in all cases for a range of orifice area from 0.3 to 3.0 cm2, initial pressure gradient from 2.4 to 14.2 mm Hg and net chamber compliance from 16 to 29 cc/mm Hg. This mathematic formulation of transmitral flow should help to unify the Doppler echocardiographic and catheterization assessment of mitral stenosis and left ventricular diastolic dysfunction.
Rakebrandt, F; Palombo, C; Swampillai, J; Schön, F; Donald, A; Kozàkovà, M; Kato, K; Fraser, A G
2009-02-01
Wave intensity (WI) in the circulation is estimated noninvasively as the product of instantaneous changes in pressure and velocity. We recorded diameter as a surrogate for pressure, and velocity in the right common carotid artery using an Aloka SSD-5500 ultrasound scanner. We developed automated software, applying the water hammer equation to obtain local wave speed from the slope of a pressure/velocity loop during early systole to separate net WI into individual forwards and backwards-running waves. A quality index was developed to test for noisy data. The timing, duration, peak amplitude and net energy of separated WI components were measured in healthy subjects with a wide age range. Age and arterial stiffness were independent predictors of local wave speed, whereas backwards-travelling waves correlated more strongly with ventricular systolic function than with age-related changes in arterial stiffness. Separated WI offers detailed insight into ventricular-arterial interactions that may be useful for assessing the relative contributions of ventricular and vascular function to wave travel.
Diastolic viscous properties of the intact canine left ventricle.
Nikolic, S D; Tamura, K; Tamura, T; Dahm, M; Frater, R W; Yellin, E L
1990-08-01
The viscoelastic model of the ventricle predicts that the rate of change of volume (strain rate) is a determinant of the instantaneous pressure in the ventricle during diastole. Because relaxation is not complete before the onset of filling, one cannot distinguish the individual effects of relaxation and viscosity unless the passive and active components that determine the ventricular pressure are separated. To overcome this problem, we used the method of ventricular volume clamping to compare the pressures in the fully relaxed ventricle at a given volume at zero strain rate (static pressure) and high strain rate (dynamic pressure). Six open-chest, fentanyl-anesthetized dogs were instrumented with micromanometers and an electronically controlled mitral valve occluder in series with the electromagnetic flow probe. We reasoned as follows: If there were significant viscosity, then the dynamic pressure would be higher than the static pressure. The static pressure was measured when the ventricle was completely relaxed following a mitral valve occlusion after an arbitrary filling volume had been achieved. The dynamic pressure was determined by delaying the onset of filling until relaxation was complete and then measuring the pressure at the same volume that was achieved when the static pressure was measured. In 19 different hemodynamic situations, the dynamic and static pressures were identical (mean difference, 0.1 +/- 0.8 mm Hg), indicating that in the passive ventricle viscoelastic effects are insignificant and do not contribute to the left ventricular diastolic pressure under normal filling rates.
Birch, A A; Eynon, C A; Schley, D
2006-01-01
The objective of this report is to highlight the potential for false pressure measurements from systems that combine intracranial pressure (ICP) measurement and ventricular drainage. If the ports of the drain become blocked to the extent that they present a high resistance to cerebrospinal fluid flow, then a significant pressure gradient between the inside and outside of the catheter may be established. Thus, any intracatheter transducer will faithfully record a pressure much lower than true ICP. This holds true for catheter-tip transducers when the transducer lies inside the catheter. In the absence of flow, however, pressures will equalize; therefore, accurate measurements may be taken if the drain is temporarily closed. We model this situation and provide simulations of expected measurements in such situations; these compare well to observed clinical readings.
Li, Qiao; Mark, Roger G; Clifford, Gari D
2009-01-01
Background Within the intensive care unit (ICU), arterial blood pressure (ABP) is typically recorded at different (and sometimes uneven) sampling frequencies, and from different sensors, and is often corrupted by different artifacts and noise which are often non-Gaussian, nonlinear and nonstationary. Extracting robust parameters from such signals, and providing confidences in the estimates is therefore difficult and requires an adaptive filtering approach which accounts for artifact types. Methods Using a large ICU database, and over 6000 hours of simultaneously acquired electrocardiogram (ECG) and ABP waveforms sampled at 125 Hz from a 437 patient subset, we documented six general types of ABP artifact. We describe a new ABP signal quality index (SQI), based upon the combination of two previously reported signal quality measures weighted together. One index measures morphological normality, and the other degradation due to noise. After extracting a 6084-hour subset of clean data using our SQI, we evaluated a new robust tracking algorithm for estimating blood pressure and heart rate (HR) based upon a Kalman Filter (KF) with an update sequence modified by the KF innovation sequence and the value of the SQI. In order to do this, we have created six novel models of different categories of artifacts that we have identified in our ABP waveform data. These artifact models were then injected into clean ABP waveforms in a controlled manner. Clinical blood pressure (systolic, mean and diastolic) estimates were then made from the ABP waveforms for both clean and corrupted data. The mean absolute error for systolic, mean and diastolic blood pressure was then calculated for different levels of artifact pollution to provide estimates of expected errors given a single value of the SQI. Results Our artifact models demonstrate that artifact types have differing effects on systolic, diastolic and mean ABP estimates. We show that, for most artifact types, diastolic ABP estimates are less noise-sensitive than mean ABP estimates, which in turn are more robust than systolic ABP estimates. We also show that our SQI can provide error bounds for both HR and ABP estimates. Conclusion The KF/SQI-fusion method described in this article was shown to provide an accurate estimate of blood pressure and HR derived from the ABP waveform even in the presence of high levels of persistent noise and artifact, and during extreme bradycardia and tachycardia. Differences in error between artifact types, measurement sensors and the quality of the source signal can be factored into physiological estimation using an unbiased adaptive filter, signal innovation and signal quality measures. PMID:19586547
Xiang, J; Siddiqui, A H; Meng, H
2014-12-18
Due to the lack of patient-specific inlet flow waveform measurements, most computational fluid dynamics (CFD) simulations of intracranial aneurysms usually employ waveforms that are not patient-specific as inlet boundary conditions for the computational model. The current study examined how this assumption affects the predicted hemodynamics in patient-specific aneurysm geometries. We examined wall shear stress (WSS) and oscillatory shear index (OSI), the two most widely studied hemodynamic quantities that have been shown to predict aneurysm rupture, as well as maximal WSS (MWSS), energy loss (EL) and pressure loss coefficient (PLc). Sixteen pulsatile CFD simulations were carried out on four typical saccular aneurysms using 4 different waveforms and an identical inflow rate as inlet boundary conditions. Our results demonstrated that under the same mean inflow rate, different waveforms produced almost identical WSS distributions and WSS magnitudes, similar OSI distributions but drastically different OSI magnitudes. The OSI magnitude is correlated with the pulsatility index of the waveform. Furthermore, there is a linear relationship between aneurysm-averaged OSI values calculated from one waveform and those calculated from another waveform. In addition, different waveforms produced similar MWSS, EL and PLc in each aneurysm. In conclusion, inlet waveform has minimal effects on WSS, OSI distribution, MWSS, EL and PLc and a strong effect on OSI magnitude, but aneurysm-averaged OSI from different waveforms has a strong linear correlation with each other across different aneurysms, indicating that for the same aneurysm cohort, different waveforms can consistently stratify (rank) OSI of aneurysms. Copyright © 2014 Elsevier Ltd. All rights reserved.
Lane, Abbi D; Kappus, Rebecca M; Bunsawat, Kanokwan; Ranadive, Sushant M; Yan, Huimin; Phillips, Shane; Baynard, Tracy; Woods, Jeffrey A; Motl, Robert; Fernhall, Bo
2015-07-01
Aging is commonly accompanied by increased arterial and ventricular stiffness (determined by arterial elastance (Ea) and ventricular elastance (Elv)), augmented ventricular-vascular coupling ratios (Ea/Elv) and systemic inflammation. Acute inflammation may impact ventricular-vascular coupling and predispose older adults to cardiovascular events. However, physically active older adults have more compliant large arteries and left ventricles and lower inflammation than sedentary older adults. We hypothesized that acute inflammation would alter Ea, Elv, and Ea/Elv more in older versus younger adults but that higher levels of physical activity would attenuate inflammation-induced changes. End-systolic and central blood pressures were obtained using applanation tonometry before and at 24 and 48 h post-influenza vaccination in 24 older and 38 younger adults. Ultrasonography was used to measure ventricular volumes and other indices of cardiac performance. Physical activity was measured with accelerometry. Ea and Ea/Elv were maintained (p > 0.05), but Elv was reduced (p < 0.05) 24 h post-inflammation. Other indices of systolic performance were reduced in older but not younger adults; diastolic performance was attenuated in both groups 24 h post-inflammation (p < 0.05 for all). Older, but not younger, adults decreased central pressure during inflammation (p < 0.05). When controlled for age, physical activity was not related to the inflammation-induced changes in elastance (p > 0.05) except in the most active group of seniors (p < 0.05). Aging did not affect the elastance responses but did affect central blood pressure and other ventricular systolic responses to acute inflammation. Aging, not physical activity, appears to modulate cardiovascular responses to acute inflammation, except in the most active older adults. © The European Society of Cardiology 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Lu, Zhongbing; Xu, Xin; Hu, Xinli; Zhu, Guangshuo; Zhang, Ping; van Deel, Elza D.; French, Joel P.; Fassett, John T.; Oury, Tim D.; Bache, Robert J.; Chen, Yingjie
2008-01-01
Extracellular superoxide dismutase (SOD) contributes only a small fraction to total SOD activity in the normal heart but is strategically located to scavenge free radicals in the extracellular compartment. To examine the physiological significance of extracellular SOD in the response of the heart to hemodynamic stress, we studied the effect of extracellular SOD deficiency on transverse aortic constriction (TAC)–induced left ventricular remodeling. Under unstressed conditions extracellular SOD deficiency had no effect on myocardial total SOD activity, the ratio of glutathione:glutathione disulfide, nitrotyrosine content, or superoxide anion production but resulted in small but significant increases in myocardial fibrosis and ventricular mass. In response to TAC for 6 weeks, extracellular SOD-deficient mice developed more severe left ventricular hypertrophy (heart weight increased 2.56-fold in extracellular SOD-deficient mice as compared with 1.99-fold in wild-type mice) and pulmonary congestion (lung weight increased 2.92-fold in extracellular SOD-deficient mice as compared with 1.84-fold in wild-type mice). Extracellular SOD-deficient mice also had more ventricular fibrosis, dilation, and a greater reduction of left ventricular fractional shortening and rate of pressure development after TAC. TAC resulted in greater increases of ventricular collagen I, collagen III, matrix metalloproteinase-2, matrix metalloproteinase-9, nitrotyrosine, and superoxide anion production. TAC also resulted in a greater decrease of the ratio of glutathione:glutathione disulfide in extracellular SOD-deficient mice. The finding that extracellular SOD deficiency had minimal impact on myocardial overall SOD activity but exacerbated TAC induced myocardial oxidative stress, hypertrophy, fibrosis, and dysfunction indicates that the distribution of extracellular SOD in the extracellular space is critically important in protecting the heart against pressure overload. PMID:17998475
NASA Astrophysics Data System (ADS)
Convertino, V. A.; Koenig, S. C.; Krotov, V. P.; Fanton, J. W.; Korolkov, V. I.; Trambovetsky, E. V.; Ewert, D. L.; Truzhennikov, A.; Latham, R. D.
Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 ° head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 ° upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alterating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Koenig, S. C.; Krotov, V. P.; Fanton, J. W.; Korolkov, V. I.; Trambovetsky, E. V.; Ewert, D. L.; Truzhennikov, A.; Latham, R. D.
1998-01-01
Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 degrees head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 degrees upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alternating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.
Alastruey, Jordi; Hunt, Anthony A E; Weinberg, Peter D
2014-01-01
We present a novel analysis of arterial pulse wave propagation that combines traditional wave intensity analysis with identification of Windkessel pressures to account for the effect on the pressure waveform of peripheral wave reflections. Using haemodynamic data measured in vivo in the rabbit or generated numerically in models of human compliant vessels, we show that traditional wave intensity analysis identifies the timing, direction and magnitude of the predominant waves that shape aortic pressure and flow waveforms in systole, but fails to identify the effect of peripheral reflections. These reflections persist for several cardiac cycles and make up most of the pressure waveform, especially in diastole and early systole. Ignoring peripheral reflections leads to an erroneous indication of a reflection-free period in early systole and additional error in the estimates of (i) pulse wave velocity at the ascending aorta given by the PU–loop method (9.5% error) and (ii) transit time to a dominant reflection site calculated from the wave intensity profile (27% error). These errors decreased to 1.3% and 10%, respectively, when accounting for peripheral reflections. Using our new analysis, we investigate the effect of vessel compliance and peripheral resistance on wave intensity, peripheral reflections and reflections originating in previous cardiac cycles. PMID:24132888
Sun, Junfeng; Qian, Hua; Li, Xiaoguang; Tang, Xianling
2017-03-01
QishenYiqi Dripping Pill (QYDP) is a Chinese herbal medicine that originally was used for the treatment of coronary artery disease. Recently, QYDP was used as a complementary treatment for heart failure (HF) in China. An HF rat model was used to clarify the possible therapeutic effects of QYDP on HF. The HF rats were allocated to two groups, HF and HF+QYDP, while normal rats served as a negative control. Cardiac functions were evaluated echocardiographically and hemodynamically. Cardiac apoptosis and the expression of β-adrenergic receptors were also investigated. Compared to the HF group, rats in the HF+QYDP group had a significantly higher fraction shortening (p<0.05), ejection fraction (p<0.05), left ventricular systolic pressure (p<0.05), maximum positive derivatives of left ventricular pressure (p<0.05), maximum negative derivatives of left ventricular pressure (p<0.05), and β2-adrenergic receptor expression (p<0.05), and lower left ventricular end-diastolic pressure (p<0.05) and apoptotic index (p<0.05). The study results indicated that QYDP could efficiently improve HF, possibly by an inhibition of cardiac apoptosis via the β2-adrenergic receptor signaling pathway. Hence, QYDP might be a promising candidate drug for HF therapy.
Microtubule Stabilization in Pressure Overload Cardiac Hypertrophy
Sato, Hiroshi; Nagai, Toshio; Kuppuswamy, Dhandapani; Narishige, Takahiro; Koide, Masaaki; Menick, Donald R.; IV, George Cooper
1997-01-01
Increased microtubule density, for which microtubule stabilization is one potential mechanism, causes contractile dysfunction in cardiac hypertrophy. After microtubule assembly, α-tubulin undergoes two, likely sequential, time-dependent posttranslational changes: reversible carboxy-terminal detyrosination (Tyr-tubulin ↔ Glu-tubulin) and then irreversible deglutamination (Glu-tubulin → Δ2-tubulin), such that Glu- and Δ2-tubulin are markers for long-lived, stable microtubules. Therefore, we generated antibodies for Tyr-, Glu-, and Δ2-tubulin and used them for staining of right and left ventricular cardiocytes from control cats and cats with right ventricular hypertrophy. Tyr- tubulin microtubule staining was equal in right and left ventricular cardiocytes of control cats, but Glu-tubulin and Δ2-tubulin staining were insignificant, i.e., the microtubules were labile. However, Glu- and Δ2-tubulin were conspicuous in microtubules of right ventricular cardiocytes from pressure overloaded cats, i.e., the microtubules were stable. This finding was confirmed in terms of increased microtubule drug and cold stability in the hypertrophied cells. In further studies, we found an increase in a microtubule binding protein, microtubule-associated protein 4, on both mRNA and protein levels in pressure-hypertrophied myocardium. Thus, microtubule stabilization, likely facilitated by binding of a microtubule-associated protein, may be a mechanism for the increased microtubule density characteristic of pressure overload cardiac hypertrophy. PMID:9362514
Sacco, Federica; Paun, Bruno; Lehmkuhl, Oriol; Iles, Tinen L; Iaizzo, Paul A; Houzeaux, Guillaume; Vázquez, Mariano; Butakoff, Constantine; Aguado-Sierra, Jazmin
2018-06-11
Computational modelling plays an important role in right ventricular (RV) haemodynamic analysis. However, current approaches employ smoothed ventricular anatomies. The aim of this study is to characterise RV haemodynamics including detailed endocardial structures like trabeculae, moderator band and papillary muscles (PMs). Four paired detailed and smoothed RV endocardium models (two male and two female) were reconstructed from ex-vivo human hearts high-resolution magnetic resonance images (MRI). Detailed models include structures with ≥1 mm 2 cross-sectional area. Haemodynamic characterisation was done by computational fluid dynamics (CFD) simulations with steady and transient inflows, using high performance computing (HPC). The differences between the flows in smoothed and detailed models were assessed using Q-criterion for vorticity quantification, the pressure drop between inlet and outlet, and the wall shear stress (WSS). Results demonstrated that detailed endocardial structures increase the degree of intra-ventricular pressure drop, decrease the WSS and disrupt the dominant vortex creating secondary small vortices. Increasingly turbulent blood flow was observed in the detailed RVs. Female RVs were less trabeculated and presented lower pressure drops than the males. In conclusion, neglecting endocardial structures in RV haemodynamic models may lead to inaccurate conclusions about the pressures, stresses, and blood flow behaviour in the cavity. This article is protected by copyright. All rights reserved.
Sulter, A M; Wit, H P
1996-11-01
Glottal volume velocity waveform characteristics of 224 subjects, categorized in four groups according to gender and vocal training, were determined, and their relations to sound-pressure level, fundamental frequency, intra-oral pressure, and age were analyzed. Subjects phonated at three intensity conditions. The glottal volume velocity waveforms were obtained by inverse filtering the oral flow. Glottal volume velocity waveforms were parameterized with flow-based (minimum flow, ac flow, average flow, maximum flow declination rate) and time-based parameters (closed quotient, closing quotient, speed quotient), as well as with derived parameters (vocal efficiency and glottal resistance). Higher sound-pressure levels, intra-oral pressures, and flow-parameter values (ac flow, maximum flow declination rate) were observed, when compared with previous investigations. These higher values might be the result of the specific phonation tasks (stressed /ae/ vowel in a word and a sentence) or filtering processes. Few statistically significant (p < 0.01) differences in parameters were found between untrained and trained subjects [the maximum flow declination rate and the closing quotient were higher in trained women (p < 0.001), and the speed quotient was higher in trained men (p < 0.005)]. Several statistically significant parameter differences were found between men and women [minimum flow, ac flow, average flow, maximum flow declination rate, closing quotient, glottal resistance (p < 0.001), and closed quotient (p < 0.005)]. Significant effects of intensity condition were observed on ac flow, maximum flow declination rate, closing quotient, and vocal efficiency in women (p < 0.005), and on minimum flow, ac flow, average flow, maximum flow declination rate, closed quotient, and vocal efficiency in men (p < 0.01).
Modeling of the dolphin's clicking sound source: The influence of the critical parameters
NASA Astrophysics Data System (ADS)
Dubrovsky, N. A.; Gladilin, A.; Møhl, B.; Wahlberg, M.
2004-07-01
A physical and a mathematical models of the dolphin’s source of echolocation clicks have been recently proposed. The physical model includes a bottle of pressurized air connected to the atmosphere with an underwater rubber tube. A compressing rubber ring is placed on the underwater portion of the tube. The ring blocks the air jet passing through the tube from the bottle. This ring can be brought into self-oscillation by the air jet. In the simplest case, the ring displacement follows a repeated triangular waveform. Because the acoustic pressure gradient is proportional to the second time derivative of the displacement, clicks arise at the bends of the displacement waveform. The mathematical model describes the dipole oscillations of a sphere “frozen” in the ring and calculates the waveform and the sound pressure of the generated clicks. The critical parameters of the mathematical model are the radius of the sphere and the peak value and duration of the triangular displacement curve. This model allows one to solve both the forward (deriving the properties of acoustic clicks from the known source parameters) and the inverse (calculating the source parameters from the acoustic data) problems. Data from click records of Odontocetes were used to derive both the displacement waveforms and the size of the “frozen sphere” or a structure functionally similar to it. The mathematical model predicts a maximum source level of up to 235 dB re 1 μPa at 1-m range when using a 5-cm radius of the “frozen” sphere and a 4-mm maximal displacement. The predicted sound pressure level is similar to that of the clicks produced by Odontocetest.
Filippidis, Aristotelis S; Kalani, M Yashar S; Nakaji, Peter; Rekate, Harold L
2011-11-01
Negative-pressure and low-pressure hydrocephalus are rare clinical entities that are frequently misdiagnosed. They are characterized by recurrent episodes of shunt failure because the intracranial pressure is lower than the opening pressure of the valve. In this report the authors discuss iatrogenic CSF leaks as a cause of low- or negative-pressure hydrocephalus after approaches to the cranial base. The authors retrospectively reviewed cases of low-pressure or negative-pressure hydrocephalus presenting after cranial approaches complicated with a CSF leak at their institution. Three patients were identified. Symptoms of high intracranial pressure and ventriculomegaly were present, although the measured pressures were low or negative. A blocked communication between the ventricles and the subarachnoid space was documented in 2 of the cases and presumed in the third. Shunt revisions failed repeatedly. In all cases, temporary clinical and radiographic improvement resulted from external ventricular drainage at subatmospheric pressures. The CSF leaks were sealed and CSF communication was reestablished operatively. In 1 case, neck wrapping was used with temporary success. Negative-pressure or low-pressure hydrocephalus associated with CSF leaks, especially after cranial base approaches, is difficult to treat. The solution often requires the utilization of subatmospheric external ventricular drains to establish a lower ventricular drainage pressure than the drainage pressure created in the subarachnoid space, where the pressure is artificially lowered by the CSF leak. Treatment involves correction of the CSF leak, neck wrapping to increase brain turgor and allow the pressure in the ventricles to rise to the level of the opening pressure of the valve, and reestablishing the CSF route.
Effects of Obesity on Cardiovascular Hemodynamics, Cardiac Morphology, and Ventricular Function.
Alpert, Martin A; Omran, Jad; Bostick, Brian P
2016-12-01
Obesity produces a variety of hemodynamic alterations that may cause changes in cardiac morphology which predispose to left and right ventricular dysfunction. Various neurohormonal and metabolic alterations commonly associated with obesity may contribute to these abnormalities of cardiac structure and function. These changes in cardiovascular hemodynamics, cardiac morphology, and ventricular function may, in severely obese patients, predispose to heart failure, even in the absence of other forms of heart disease (obesity cardiomyopathy). In normotensive obese patients, cardiac involvement is commonly characterized by elevated cardiac output, low peripheral vascular resistance, and increased left ventricular (LV) end-diastolic pressure. Sleep-disordered breathing may lead to pulmonary arterial hypertension and, in association with left heart failure, may contribute to elevation of right heart pressures. These alterations, in association with various neurohormonal and metabolic abnormalities, may produce LV hypertrophy; impaired LV diastolic function; and less commonly, LV systolic dysfunction. Many of these alterations are reversible with substantial voluntary weight loss.
Doppler-guided retrograde catheterization system
NASA Astrophysics Data System (ADS)
Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.
1991-05-01
The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the catheter tip is placed in the aortic root. Such technology may conceivably assist in allowing selective coronary catheterization. These studies have demonstrated that Doppler guided retrograde catheterization provides an accurate method to catheterization the aortic root and left ventricular chamber without x-ray. In humans, it may prove useful in a variety of settings including the development of invasive ultrasonic diagnostic and therapeutic technology.
[Experts consensus on the management of the right heart function in critically ill patients].
Wang, X T; Liu, D W; Zhang, H M; Long, Y; Guan, X D; Qiu, H B; Yu, K J; Yan, J; Zhao, H; Tang, Y Q; Ding, X; Ma, X C; Du, W; Kang, Y; Tang, B; Ai, Y H; He, H W; Chen, D C; Chen, H; Chai, W Z; Zhou, X; Cui, N; Wang, H; Rui, X; Hu, Z J; Li, J G; Xu, Y; Yang, Y; Ouyan, B; Lin, H Y; Li, Y M; Wan, X Y; Yang, R L; Qin, Y Z; Chao, Y G; Xie, Z Y; Sun, R H; He, Z Y; Wang, D F; Huang, Q Q; Jiang, D P; Cao, X Y; Yu, R G; Wang, X; Chen, X K; Wu, J F; Zhang, L N; Yin, M G; Liu, L X; Li, S W; Chen, Z J; Luo, Z
2017-12-01
To establish the experts consensus on the right heart function management in critically ill patients. The panel of consensus was composed of 30 experts in critical care medicine who are all members of Critical Hemodynamic Therapy Collaboration Group (CHTC Group). Each statement was assessed based on the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) principle. Then the Delphi method was adopted by 52 experts to reassess all the statements. (1) Right heart function is prone to be affected in critically illness, which will result in a auto-exaggerated vicious cycle. (2) Right heart function management is a key step of the hemodynamic therapy in critically ill patients. (3) Fluid resuscitation means the process of fluid therapy through rapid adjustment of intravascular volume aiming to improve tissue perfusion. Reversed fluid resuscitation means reducing volume. (4) The right ventricle afterload should be taken into consideration when using stroke volume variation (SVV) or pulse pressure variation (PPV) to assess fluid responsiveness.(5)Volume overload alone could lead to septal displacement and damage the diastolic function of the left ventricle. (6) The Starling curve of the right ventricle is not the same as the one applied to the left ventricle,the judgement of the different states for the right ventricle is the key of volume management. (7) The alteration of right heart function has its own characteristics, volume assessment and adjustment is an important part of the treatment of right ventricular dysfunction (8) Right ventricular enlargement is the prerequisite for increased cardiac output during reversed fluid resuscitation; Nonetheless, right heart enlargement does not mandate reversed fluid resuscitation.(9)Increased pulmonary vascular resistance induced by a variety of factors could affect right heart function by obstructing the blood flow. (10) When pulmonary hypertension was detected in clinical scenario, the differentiation of critical care-related pulmonary hypertension should be a priority. (11) Attention should be paid to the change of right heart function before and after implementation of mechanical ventilation and adjustment of ventilator parameter. (12) The pulmonary arterial pressure should be monitored timingly when dealing with critical care-related pulmonary hypertension accompanied with circulatory failure.(13) The elevation of pulmonary aterial pressure should be taken into account in critical patients with acute right heart dysfunction. (14) Prone position ventilation is an important measure to reduce pulmonary vascular resistance when treating acute respiratory distress syndrome patients accompanied with acute cor pulmonale. (15) Attention should be paid to right ventricle-pulmonary artery coupling during the management of right heart function. (16) Right ventricular diastolic function is more prone to be affected in critically ill patients, the application of critical ultrasound is more conducive to quantitative assessment of right ventricular diastolic function. (17) As one of the parameters to assess the filling pressure of right heart, central venous pressure can be used to assess right heart diastolic function. (18). The early and prominent manifestation of non-focal cardiac tamponade is right ventricular diastolic involvement, the elevated right atrial pressure should be noticed. (19) The effect of increased intrathoracic pressure on right heart diastolic function should be valued. (20) Ttricuspid annular plane systolic excursion (TAPSE) is an important parameter that reflects right ventricular systolic function, and it is recommended as a general indicator of critically ill patient. (21) Circulation management with right heart protection as the core strategy is the key point of the treatment of acute respiratory distress syndrome. (22) Right heart function involvement after cardiac surgery is very common and should be highly valued. (23) Right ventricular dysfunction should not be considered as a routine excuse for maintaining higher central venous pressure. (24) When left ventricular dilation, attention should be paid to the effect of left ventricle on right ventricular diastolic function. (25) The impact of left ventricular function should be excluded when the contractility of the right ventricle is decreased. (26) When the right heart load increases acutely, the shunt between the left and right heart should be monitored. (27) Attention should be paid to the increase of central venous pressure caused by right ventricular dysfunction and its influence on microcirculation blood flow. (28) When the vasoactive drugs was used to reduce the pressure of pulmonary circulation, different effects on pulmonary and systemic circulation should be evaluated. (29) Right atrial pressure is an important factor affecting venous return. Attention should be paid to the influence of the pressure composition of the right atrium on the venous return. (30) Attention should be paid to the role of the right ventricle in the acute pulmonary edema. (31) Monitoring the difference between the mean systemic filling pressure and the right atrial pressure is helpful to determine whether the infusion increases the venous return. (32) Venous return resistance is often considered to be a insignificant factor that affects venous return, but attention should be paid to the effect of the specific pathophysiological status, such as intrathoracic hypertension, intra-abdominal hypertension and so on. Consensus can promote right heart function management in critically ill patients, optimize hemodynamic therapy, and even affect prognosis.
Importance of Calibration Method in Central Blood Pressure for Cardiac Structural Abnormalities.
Negishi, Kazuaki; Yang, Hong; Wang, Ying; Nolan, Mark T; Negishi, Tomoko; Pathan, Faraz; Marwick, Thomas H; Sharman, James E
2016-09-01
Central blood pressure (CBP) independently predicts cardiovascular risk, but calibration methods may affect accuracy of central systolic blood pressure (CSBP). Standard central systolic blood pressure (Stan-CSBP) from peripheral waveforms is usually derived with calibration using brachial SBP and diastolic BP (DBP). However, calibration using oscillometric mean arterial pressure (MAP) and DBP (MAP-CSBP) is purported to provide more accurate representation of true invasive CSBP. This study sought to determine which derived CSBP could more accurately discriminate cardiac structural abnormalities. A total of 349 community-based patients with risk factors (71±5years, 161 males) had CSBP measured by brachial oscillometry (Mobil-O-Graph, IEM GmbH, Stolberg, Germany) using 2 calibration methods: MAP-CSBP and Stan-CSBP. Left ventricular hypertrophy (LVH) and left atrial dilatation (LAD) were measured based on standard guidelines. MAP-CSBP was higher than Stan-CSBP (149±20 vs. 128±15mm Hg, P < 0.0001). Although they were modestly correlated (rho = 0.74, P < 0.001), the Bland-Altman plot demonstrated a large bias (21mm Hg) and limits of agreement (24mm Hg). In receiver operating characteristic (ROC) curve analyses, MAP-CSBP significantly better discriminated LVH compared with Stan-CSBP (area under the curve (AUC) 0.66 vs. 0.59, P = 0.0063) and brachial SBP (0.62, P = 0.027). Continuous net reclassification improvement (NRI) (P < 0.001) and integrated discrimination improvement (IDI) (P < 0.001) corroborated superior discrimination of LVH by MAP-CSBP. Similarly, MAP-CSBP better distinguished LAD than Stan-CSBP (AUC 0.63 vs. 0.56, P = 0.005) and conventional brachial SBP (0.58, P = 0.006), whereas Stan-CSBP provided no better discrimination than conventional brachial BP (P = 0.09). CSBP is calibration dependent and when oscillometric MAP and DBP are used, the derived CSBP is a better discriminator for cardiac structural abnormalities. © American Journal of Hypertension, Ltd 2016. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Model helicopter rotor high-speed impulsive noise: Measured acoustics and blade pressures
NASA Technical Reports Server (NTRS)
Boxwell, D. A.; Schmitz, F. H.; Splettstoesser, W. R.; Schultz, K. J.
1983-01-01
A 1/17-scale research model of the AH-1 series helicopter main rotor was tested. Model-rotor acoustic and simultaneous blade pressure data were recorded at high speeds where full-scale helicopter high-speed impulsive noise levels are known to be dominant. Model-rotor measurements of the peak acoustic pressure levels, waveform shapes, and directively patterns are directly compared with full-scale investigations, using an equivalent in-flight technique. Model acoustic data are shown to scale remarkably well in shape and in amplitude with full-scale results. Model rotor-blade pressures are presented for rotor operating conditions both with and without shock-like discontinuities in the radiated acoustic waveform. Acoustically, both model and full-scale measurements support current evidence that above certain high subsonic advancing-tip Mach numbers, local shock waves that exist on the rotor blades ""delocalize'' and radiate to the acoustic far-field.
Zahedi, Edmond; Sohani, Vahid; Ali, M A Mohd; Chellappan, Kalaivani; Beng, Gan Kok
2015-01-01
The feasibility of a novel system to reliably estimate the normalized central blood pressure (CBPN) from the radial photoplethysmogram (PPG) is investigated. Right-wrist radial blood pressure and left-wrist PPG were simultaneously recorded in five different days. An industry-standard applanation tonometer was employed for recording radial blood pressure. The CBP waveform was amplitude-normalized to determine CBPN. A total of fifteen second-order autoregressive models with exogenous input were investigated using system identification techniques. Among these 15 models, the model producing the lowest coefficient of variation (CV) of the fitness during the five days was selected as the reference model. Results show that the proposed model is able to faithfully reproduce CBPN (mean fitness = 85.2% ± 2.5%) from the radial PPG for all 15 segments during the five recording days. The low CV value of 3.35% suggests a stable model valid for different recording days.
Vaidyanathan, Swaminathan; Kothandam, Sivakumar; Kumar, Rajesh; Indrajith, Sujatha Desai; Agarwal, Ravi
2017-01-01
A 26-year-old lady presented with exertional dyspnea, palpitations, central cyanosis, and oxygen saturations of 80% in room air. Her electrocardiogram, echocardiogram, and cardiac magnetic resonance were diagnostic of arrhythmogenic right ventricular dysplasia. There was no documented ventricular arrhythmia or syncopal episodes and Holter recordings were repeatedly normal. Cardiac hemodynamics showed right to left shunt through atrial septal defect, low pulmonary blood flow, normal atrial pressures, and minimally elevated right ventricular end-diastolic pressures. Since her presenting symptoms and cyanosis were attributed to reduced pulmonary blood flow, she underwent off-pump cavopulmonary anastomosis between right superior vena cava and right pulmonary artery. As we intended to avoid the adverse effect of extracorporeal circulation on the myocardial function and pulmonary vasculature, we did not attempt to reduce the size of the atrial septal defect. Her postoperative period was uneventful; oxygen saturation improved to 89% with significant improvement in effort tolerance. At 18-month follow-up, there were no ventricular arrhythmias on surveillance. The clinical presentation of this disease may vary from serious arrhythmias warranting defibrillators and electrical ablations at one end to right ventricular pump failure warranting cardiomyoplasty or right ventricular exclusion procedures at the other end. However, when the presentation was unusual with severe cyanosis through a stretched foramen ovale leading to reduced pulmonary blood flows, Glenn shunt served as a good palliation and should be considered as one of the options in such patients.
NASA Technical Reports Server (NTRS)
Steinetz, Bruce M. (Inventor)
2006-01-01
The invention relates to a sealing device having an acoustic resonator. The acoustic resonator is adapted to create acoustic waveforms to generate a sealing pressure barrier blocking fluid flow from a high pressure area to a lower pressure area. The sealing device permits noncontacting sealing operation. The sealing device may include a resonant-macrosonic-synthesis (RMS) resonator.
NASA Technical Reports Server (NTRS)
Steinetz, Bruce M. (Inventor)
2006-01-01
The invention relates to a sealing device having an acoustic resonator. The acoustic resonator is adapted to create acoustic waveforms to generate a sealing pressure barrier blocking fluid flow from a high pressure area to a lower pressure area. The sealing device permits noncontacting sealing operation. The sealing device may include a resonant-macrosonic-synthesis (RMS) resonator.
Styczynski, Grzegorz; Rdzanek, Adam; Pietrasik, Arkadiusz; Kochman, Janusz; Huczek, Zenon; Sobieraj, Piotr; Gaciong, Zbigniew; Szmigielski, Cezary
2016-11-01
Aortic pulse-wave velocity (PWV) is a measure of aortic stiffness that has a prognostic role in various diseases and in the general population. A number of methods are used to measure PWV, including Doppler ultrasound. Although echocardiography has been used for PWV measurement, to the authors' knowledge, it has never been tested against an invasive reference method at the same time point. Therefore, the aim of this study was to compare prospectively an echocardiographic PWV measurement, called echo-PWV, with an invasive study. Forty-five patients (mean age, 66 years; 60% men) underwent simultaneous intra-arterial pressure recording and echocardiographic Doppler flow evaluation during elective cardiac catheterization. Proximal pressure and Doppler waveforms were acquired in the aortic arch. Distal pressure waveforms were registered in the right and distal Doppler waveforms in the left external iliac artery. Transit time was measured as a delay of the foot of pressure or Doppler waveform in the distal relative to the proximal location. Distance was measured on the catheter for invasive PWV and over the surface for echo-PWV. Echo-PWV was calculated as distance divided by transit time. In the whole group, mean invasive PWV was 9.38 m/sec and mean echo-PWV was 9.51 m/sec (P = .78). The Pearson' correlation coefficient between methods was 0.93 (P < .0001). A Bland-Altman plot revealed a mean difference between invasive PWV and echo-PWV of 0.13 ± 0.79 m/sec. Echo-PWV, based on Doppler echocardiography, is a reliable method of aortic PWV measurement, with a close correlation with invasive assessment. Wider implementation of the echo-PWV method for the evaluation of aortic wall stiffness can further expand the clinical and scientific utility of echocardiography. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Honda, Takashi; Itatani, Keiichi; Takanashi, Manabu; Kitagawa, Atsushi; Ando, Hisashi; Kimura, Sumito; Oka, Norihiko; Miyaji, Kagami; Ishii, Masahiro
2017-10-01
Vector flow mapping is a novel echocardiographic flow visualization method, and it has enabled us to quantitatively evaluate the energy loss in the left ventricle (intraventricular energy loss). Although intraventricular energy loss is assumed to be a part of left ventricular workload itself, it is unclear what this parameter actually represents. The aim of the present study was to elucidate the characteristics of intraventricular energy loss. We enrolled 26 consecutive children with ventricular septal defect (VSD). On echocardiography vector flow mapping, intraventricular energy loss was measured in the apical 3-chamber view. We measured peak energy loss and averaged energy loss in the diastolic and systolic phases, and subsequently compared these parameters with catheterization parameters and serum brain natrium peptide (BNP) level. Diastolic, peak, and systolic energy loss were strongly and positively correlated with right ventricular systolic pressure (r=0.76, 0.68, and 0.56, p<0.0001, = 0.0001, and 0.0029, respectively) and right ventricular end diastolic pressure (r=0.55, 0.49, and 0.49, p=0.0038, 0.0120, and 0.0111, respectively). In addition, diastolic, peak, and systolic energy loss were significantly correlated with BNP (r=0.75, 0.69 and 0.49, p<0.0001, < 0.0001, and=0.0116, respectively). In children with VSD, elevated right ventricular pressure is one of the factors that increase energy loss in the left ventricle. The results of the present study encourage further studies in other study populations to elucidate the characteristics of intraventricular energy loss for its possible clinical application. Copyright © 2017 Elsevier B.V. All rights reserved.
Asymptomatic cardiopulmonary changes caused by adenoid hypertrophy.
Abdel-Aziz, Mosaad
2011-07-01
Adenoid hypertrophy is the most common cause of pediatric upper airway obstruction, and it can lead to cardiopulmonary complications such as pulmonary hypertension, cor pulmonale, and even heart failure. The aim of this study was to detect the asymptomatic cardiopulmonary changes that could happen in children with adenoid hypertrophy.Eighty children with adenoid hypertrophy were included in this study. Chest x-ray was used to assess the cardiothoracic ratio, whereas echocardiography was used for measuring the pulmonary arterial pressures, right ventricular diastolic filling parameters, and right ventricular end-diastolic diameters. All patients underwent adenoidectomy with or without tonsillectomy, and they were subjected again to echocardiographic assessment 6 months after the operation. No patient showed an increase in the cardiothoracic ratio on x-ray. Preoperative echocardiography showed an increase in pulmonary artery pressure (22.7 [SD, 3.8] mm Hg), a decrease in right ventricular diastolic filling parameters (E/A = 1.03 [SD, 0.17]), and an increase in right ventricular end-diastolic diameters (1.89 [SD, 0.19] cm). Postoperatively, pulmonary artery pressure decreased to 17.2 [SD, 2.1] mm Hg, right ventricular diastolic filling (E/A) increased to 1.25 [SD, 0.11], and right ventricular end-diastolic diameters decreased to 1.68 [SD, 0.12] cm. The comparison between preoperative and postoperative results for each individual parameter was statistically significant. Clinically asymptomatic cardiopulmonary changes due to adenoid hypertrophy are not rare. Early diagnosis and treatment of upper airway obstruction can prevent these serious complications. Echocardiographic examination should be recommended for these patients as a part of preoperative preparation to avoid anesthetic complications.
A Rat Model of Ventricular Fibrillation and Resuscitation by Conventional Closed-chest Technique
Lamoureux, Lorissa; Radhakrishnan, Jeejabai; Gazmuri, Raúl J.
2015-01-01
A rat model of electrically-induced ventricular fibrillation followed by cardiac resuscitation using a closed chest technique that incorporates the basic components of cardiopulmonary resuscitation in humans is herein described. The model was developed in 1988 and has been used in approximately 70 peer-reviewed publications examining a myriad of resuscitation aspects including its physiology and pathophysiology, determinants of resuscitability, pharmacologic interventions, and even the effects of cell therapies. The model featured in this presentation includes: (1) vascular catheterization to measure aortic and right atrial pressures, to measure cardiac output by thermodilution, and to electrically induce ventricular fibrillation; and (2) tracheal intubation for positive pressure ventilation with oxygen enriched gas and assessment of the end-tidal CO2. A typical sequence of intervention entails: (1) electrical induction of ventricular fibrillation, (2) chest compression using a mechanical piston device concomitantly with positive pressure ventilation delivering oxygen-enriched gas, (3) electrical shocks to terminate ventricular fibrillation and reestablish cardiac activity, (4) assessment of post-resuscitation hemodynamic and metabolic function, and (5) assessment of survival and recovery of organ function. A robust inventory of measurements is available that includes – but is not limited to – hemodynamic, metabolic, and tissue measurements. The model has been highly effective in developing new resuscitation concepts and examining novel therapeutic interventions before their testing in larger and translationally more relevant animal models of cardiac arrest and resuscitation. PMID:25938619
Paraskevaidis, I A; Kremastinos, D T; Kassimatis, A S; Karavolias, G K; Kordosis, G D; Kyriakides, Z S; Toutouzas, P K
1993-01-01
OBJECTIVE--To determine whether an abnormal response of diastolic blood pressure during treadmill exercise stress testing correlated with the number of obstructed vessels and with left ventricular systolic function in patients with coronary artery disease. DESIGN--Diastolic blood pressure was measured invasively during exercise stress testing and coronary angiograms and left ventriculograms were obtained at rest in patients with coronary artery disease. The abnormal (> or = 15 mm Hg) diastolic blood pressure response was compared with the number of obstructed coronary arteries and with left ventricular systolic function. SETTING--Two tertiary referral centres. PATIENTS--50 consecutive patients (mean age 57 years) with coronary artery disease. MAIN OUTCOME MEASURES--The increase in diastolic blood pressure during exercise and its correlation with the appearance and disappearance of ST segment deviation, resting left ventricular systolic function, and the number of obstructed coronary arteries. RESULTS--Group 1: 10 (20%) patients (three with one, four with two, and three with three vessel coronary artery disease) (mean (SD) age 54.7 (12) years) had an abnormal diastolic blood pressure response that appeared 1.2 (0.3) min before ST segment deviation and became normal 0.9 (0.3) min after the ST segment returned to normal. Group 2: 40 (80%) patients (12 with one, 16 with two, and 12 with three vessel coronary arteries disease) (aged 56.8 (8.2) years) had a normal diastolic blood pressure response to stress testing. The ejection fraction (46.3 (5)%) and cardiac index (2.6 (0.1) 1/min/m2) in group 1 were less than in group 2 (61.6 (4.2)% and 3.8 (0.3) 1/min/m2 respectively, p < or = 0.001). The end systolic volume was greater in group 1 than in group 2: 38.7 (0.7 ml/m2 v 28.2 (2.1) ml/m2, p < or = 0.001. CONCLUSION--In patients with coronary artery disease an abnormal increase in diastolic blood pressure during exercise stress testing correlated well with left ventricular systolic function at rest but not with the number of obstructed coronary arteries. The abnormal response of diastolic blood pressure probably reflects deterioration of myocardial function. Images PMID:8343317
Waveform shape analysis: extraction of physiologically relevant information from Doppler recordings.
Ramsay, M M; Broughton Pipkin, F; Rubin, P C; Skidmore, R
1994-05-01
1. Doppler recordings were made from the brachial artery of healthy female subjects during a series of manoeuvres which altered the pressure-flow characteristics of the vessel. 2. Changes were induced in the peripheral circulation of the forearm by the application of heat or ice-packs. A sphygmomanometer cuff was used to create graded occlusion of the vessel above and below the point of measurement. Recordings were also made whilst the subjects performed a standardized Valsalva manoeuvre. 3. The Doppler recordings were analysed both with the standard waveform indices (systolic/diastolic ratio, pulsatility index and resistance index) and by the method of Laplace transform analysis. 4. The waveform parameters obtained by Laplace transform analysis distinguished the different changes in flow conditions; they thus had direct physiological relevance, unlike the standard waveform indices.
A pig model of acute right ventricular afterload increase by hypoxic pulmonary vasoconstriction.
Knai, Kathrine; Skjaervold, Nils Kristian
2017-01-03
The aim of this study was to construct a non-invasive model for acute right ventricular afterload increase by hypoxic pulmonary vasoconstriction. Intact animal models are vital to improving our understanding of the pathophysiology of acute right ventricular failure. Acute right ventricular failure is caused by increased afterload of the right ventricle by chronic or acute pulmonary hypertension combined with regionally or globally reduced right ventricular contractile capacity. Previous models are hampered by their invasiveness; this is unfortunate as the pulmonary circulation is a low-pressure system that needs to be studied in closed chest animals. Hypoxic pulmonary vasoconstriction is a mechanism that causes vasoconstriction in alveolar vessels in response to alveolar hypoxia. In this study we explored the use of hypoxic pulmonary vasoconstriction as a means to increase the pressure load on the right ventricle. Pulmonary hypertension was induced by lowering the FiO 2 to levels below the physiological range in eight anesthetized and mechanically ventilated pigs. The pigs were monitored with blood pressure measurements and blood gases. The mean pulmonary artery pressures (mPAP) of the animals increased from 18.3 (4.2) to 28.4 (4.6) mmHg and the pulmonary vascular resistance (PVR) from 254 (76) dyns/cm 5 to 504 (191) dyns/cm 5 , with a lowering of FiO 2 from 0.30 to 0.15 (0.024). The animals' individual baseline mPAPs varied substantially as did their response to hypoxia. The reduced FiO 2 level yielded an overall lowering in oxygen offer, but the global oxygen consumption was unaltered. We showed in this study that the mPAP and the PVR could be raised by approximately 100% in the study animals by lowering the FiO 2 from 0.30 to 0.15 (0.024). We therefore present a novel method for minimally invasive (closed chest) right ventricular afterload manipulations intended for future studies of acute right ventricular failure. The method should in theory be reversible, although this was not studied in this work.
Near-field shock formation in noise propagation from a high-power jet aircraft.
Gee, Kent L; Neilsen, Tracianne B; Downing, J Micah; James, Michael M; McKinley, Richard L; McKinley, Robert C; Wall, Alan T
2013-02-01
Noise measurements near the F-35A Joint Strike Fighter at military power are analyzed via spatial maps of overall and band pressure levels and skewness. Relative constancy of the pressure waveform skewness reveals that waveform asymmetry, characteristic of supersonic jets, is a source phenomenon originating farther upstream than the maximum overall level. Conversely, growth of the skewness of the time derivative with distance indicates that acoustic shocks largely form through the course of near-field propagation and are not generated explicitly by a source mechanism. These results potentially counter previous arguments that jet "crackle" is a source phenomenon.
Larstorp, Anne Cecilie K; Ariansen, Inger; Gjesdal, Knut; Olsen, Michael H; Ibsen, Hans; Devereux, Richard B; Okin, Peter M; Dahlöf, Björn; Kjeldsen, Sverre E; Wachtell, Kristian
2012-08-01
Previous studies have found pulse pressure (PP), a marker of arterial stiffness, to be an independent predictor of atrial fibrillation (AF) in general and hypertensive populations. We examined whether PP predicted new-onset AF in comparison with other blood pressure components in the Losartan Intervention For Endpoint reduction in hypertension study, a double-blind, randomized (losartan versus atenolol), parallel-group study, including 9193 patients with hypertension and electrocardiographic left ventricular hypertrophy. In 8810 patients with neither a history of AF nor AF at baseline, Minnesota coding of electrocardiograms confirmed new-onset AF in 353 patients (4.0%) during mean 4.9 years of follow-up. In multivariate Cox regression analyses, baseline and in-treatment PP and baseline and in-treatment systolic blood pressure predicted new-onset AF, independent of baseline age, height, weight, and Framingham Risk Score; sex, race, and treatment allocation; and in-treatment heart rate and Cornell product. PP was the strongest single blood pressure predictor of new-onset AF determined by the decrease in the -2 Log likelihood statistic, in comparison with systolic blood pressure, diastolic blood pressure, and mean arterial pressure. When evaluated in the same model, the predictive effect of systolic and diastolic blood pressures together was similar to that of PP. In this population of patients with hypertension and left ventricular hypertrophy, PP was the strongest single blood pressure predictor of new-onset AF, independent of other risk factors.
Genesis of multipeaked waves of the esophagus: repetitive contractions or motion artifact?
Sampath, Neha J; Bhargava, Valmik; Mittal, Ravinder K
2010-06-01
Multipeaked waves (MPW) in the distal esophagus occur frequently in patients with esophageal spastic motor disorders and diabetes mellitus and are thought to represent repetitive esophageal contractions. We aimed to investigate whether the relative motion between a stationary pressure sensor and contracted peristaltic esophageal segment that moves with respiration leads to the formation of MPW. We mathematically modeled the effect of relative movement between a moving pressure segment and a fixed pressure sensor on the pressure waveform morphology. We conducted retrospective analysis of 100 swallow-induced esophageal contractions in 10 patients, who demonstrated >30% MPW on high-resolution manometry (HRM) during standardized swallows. Finally, using HRM, we determined the effects of suspended breathing and hyperventilation on the waveform morphology in 10 patients prospectively. Modeling revealed that relative movement between a stationary pressure sensor and a moving contracted segment, contraction duration, contraction amplitude, respiratory frequency, and depth of respiration affects the waveform morphology. Retrospective analysis demonstrated a close temporal association with the onset of second and subsequent contractions in MPW with respiratory phase reversals. Numbers of peaks in MPW and respiratory phase reversals were closely related to the duration of contraction. In the prospective study, suspended breathing and hyperventilation resulted in a significant decrease and increase in the MPW frequency as well as the number of peaks within MPW respectively. We conclude that MPW observed during clinical motility studies are not indicative of repetitive esophageal contraction; rather they represent respiration-related movement of the contracted esophageal segment in relation to the stationary pressure sensor.
Lim, Pooi Khoon; Ng, Siew-Cheok; Jassim, Wissam A.; Redmond, Stephen J.; Zilany, Mohammad; Avolio, Alberto; Lim, Einly; Tan, Maw Pin; Lovell, Nigel H.
2015-01-01
We present a novel approach to improve the estimation of systolic (SBP) and diastolic blood pressure (DBP) from oscillometric waveform data using variable characteristic ratios between SBP and DBP with mean arterial pressure (MAP). This was verified in 25 healthy subjects, aged 28 ± 5 years. The multiple linear regression (MLR) and support vector regression (SVR) models were used to examine the relationship between the SBP and the DBP ratio with ten features extracted from the oscillometric waveform envelope (OWE). An automatic algorithm based on relative changes in the cuff pressure and neighbouring oscillometric pulses was proposed to remove outlier points caused by movement artifacts. Substantial reduction in the mean and standard deviation of the blood pressure estimation errors were obtained upon artifact removal. Using the sequential forward floating selection (SFFS) approach, we were able to achieve a significant reduction in the mean and standard deviation of differences between the estimated SBP values and the reference scoring (MLR: mean ± SD = −0.3 ± 5.8 mmHg; SVR and −0.6 ± 5.4 mmHg) with only two features, i.e., Ratio2 and Area3, as compared to the conventional maximum amplitude algorithm (MAA) method (mean ± SD = −1.6 ± 8.6 mmHg). Comparing the performance of both MLR and SVR models, our results showed that the MLR model was able to achieve comparable performance to that of the SVR model despite its simplicity. PMID:26087370
Unconstrained pulse pressure monitoring for health management using hetero-core fiber optic sensor.
Nishiyama, Michiko; Sonobe, Masako; Watanabe, Kazuhiro
2016-09-01
In this paper, we present a pulse pressure waveform sensor that does not constrain a wearer's daily activity; the sensor uses hetero-core fiber optics. Hetero-core fiber sensors have been found to be sensitive to moderate bending. To detect minute pulse pressure changes from the radial artery at the wrist, we devised a fiber sensor arrangement using three-point bending supports. We analyzed and evaluated the measurement validity using wavelet transformation, which is well-suited for biological signal processing. It was confirmed that the detected pulse waveform had a fundamental mode frequency of around 1.25 Hz over the time-varying waveform. A band-pass filter with a range of frequencies from 0.85 to 1.7 Hz was used to pick up the fundamental mode. In addition, a high-pass filter with 0.85 Hz frequency eliminated arm motion artifacts; consequently, we achieved high signal-to-noise ratio. For unrestricted daily health management, it is desirable that pulse pressure monitoring can be achieved by simply placing a device on the hand without the sensor being noticed. Two types of arrangements were developed and demonstrated in which the pulse sensors were either embedded in a base, such as an armrest, or in a wearable device. A wearable device without cuff pressure using a sensitivity-enhanced fiber sensor was successfully achieved with a sensitivity of 0.07-0.3 dB with a noise floor lower than 0.01 dB for multiple subjects.
Leak detection using structure-borne noise
NASA Technical Reports Server (NTRS)
Holland, Stephen D. (Inventor); Roberts, Ronald A. (Inventor); Chimenti, Dale E. (Inventor)
2010-01-01
A method for detection and location of air leaks in a pressure vessel, such as a spacecraft, includes sensing structure-borne ultrasound waveforms associated with turbulence caused by a leak from a plurality of sensors and cross correlating the waveforms to determine existence and location of the leak. Different configurations of sensors and corresponding methods can be used. An apparatus for performing the methods is also provided.
Pierce, Gary L; Casey, Darren P; Fiedorowicz, Jess G; Seals, Douglas R; Curry, Timothy B; Barnes, Jill N; Wilson, DeMaris R; Stauss, Harald M
2013-07-01
We hypothesized that demographic/anthropometric parameters can be used to estimate effective reflecting distance (EfRD), required to derive aortic pulse wave velocity (APWV), a prognostic marker of cardiovascular risk, from peripheral waveforms and that such estimates can discriminate differences in APWV and EfRD with aging and habitual endurance exercise in healthy adults. Ascending aortic pressure waveforms were derived from peripheral waveforms (brachial artery pressure, n = 25; and finger volume pulse, n = 15) via a transfer function and then used to determine the time delay between forward- and backward-traveling waves (Δtf-b). True EfRDs were computed as directly measured carotid-femoral pulse wave velocity (CFPWV) × 1/2Δtf-b and then used in regression analysis to establish an equation for EfRD based on demographic/anthropometric data (EfRD = 0.173·age + 0.661·BMI + 34.548 cm, where BMI is body mass index). We found good agreement between true and estimated APWV (Pearson's R² = 0.43; intraclass correlation = 0.64; both P < 0.05) and EfRD (R² = 0.24; intraclass correlation = 0.40; both P < 0.05). In young sedentary (22 ± 2 years, n = 6), older sedentary (62 ± 1 years, n = 24), and older endurance-trained (61 ± 2 years, n = 14) subjects, EfRD (from demographic/anthropometric parameters), APWV, and 1/2Δtf-b (from brachial artery pressure waveforms) were 52.0 ± 0.5, 61.8 ± 0.4, and 60.6 ± 0.5 cm; 6.4 ± 0.3, 9.6 ± 0.2, and 8.1 ± 0.2 m/s; and 82 ± 3, 65 ± 1 and 76 ± 2 ms (all P < 0.05), respectively. Our results demonstrate that APWV derived from peripheral waveforms using age and BMI to estimate EfRD correlates with CFPWV in healthy adults. This method can reliably detect the distal shift of the reflecting site with age and the increase in APWV with sedentary aging that is attenuated with habitual endurance exercise.
Hollow mandrin facilitates external ventricular drainage placement.
Heese, O; Regelsberger, J; Kehler, U; Westphal, M
2005-07-01
Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening intracranial pressure can be obtained performed without losing CSF.
Effect of upright tilt on ventricular/vascular coupling in chronically instrumented primates
NASA Technical Reports Server (NTRS)
Tran, C. C.; Latham, R. D.; Self, D. A.; Fanton, J. W.; White, C. D.; Owens, R. W.
1993-01-01
Studies of the hydraulic loading conditions on the heart in humans, especially pulsatile load, have primarily been limited to the supine state. Therefore, we have chosen a nonhuman primate model, the baboon, to assess left ventricular/vascular coupling in both supine and upright positions. Primate subjects were studied by catheterization under sedation and then after surgical implantation of transducers. This allowed the evaluation of postural stress in the chronically instrumented conscious baboon and then after light dissociative doses of ketamine. Basic hemodynamic variables were evaluated for baboons in supine and upright positions. Fourier analysis was applied to aortic pressure and flow to obtain input and characteristic impedance and the ratio of pulsatile (Wp) to total (Wt) left ventricular power (Wp/Wt). The aortic reflected, or backward, pressure was also calculated. Peripheral resistance increased (P = 0.01) and reflected pressure decreased (17.74 +/- 1.50 vs. 15.21 +/- 2 mmHg; P < 0.01) in upright subjects. Characteristic impedance and Wp/Wt were unchanged. Postoperatively, peripheral resistance increased (2,651 +/- 311 vs. 3,667 +/- 276; P < 0.05) and mean power and Wt decreased (P < 0.01) without changes in reflected pressure. All variables were unchanged after light dissociative doses of ketamine. Thus there is no significant change in efficiency of left ventricular/vascular coupling formulated in terms of Wp/Wt or input impedance with postural stress.
Maron, Bradley A
2014-12-01
Despite the importance of preserved right ventricular structure and function with respect to outcome across the spectrum of lung, cardiac, and pulmonary vascular diseases, only recently have organized efforts developed to consider the pulmonary vascular-right ventricular apparatus as a specific unit within the larger context of cardiopulmonary pathophysiology. The Third International Right Heart Failure Summit (Boston, MA) was a multidisciplinary event dedicated to promoting a dialogue about the scientific and clinical basis of right heart disease. The current review provides a synopsis of key discussions presented during the section of the summit titled "Emerging Hemodynamic Signatures of the Right Heart." Specifically, topics emphasized in this element of the symposium included (1) the effects of pulmonary vascular dysfunction at rest or provoked by exercise on the right ventricular pressure-volume relationship, (2) the role of pressure-volume loop analysis as a method to characterize right ventricular inefficiency and predict right heart failure, and (3) the importance of a systems biology approach to identifying novel factors that contribute to pathophenotypes associated with pulmonary arterial hypertension and/or right ventricular dysfunction. Collectively, these concepts frame a forward-thinking paradigm shift in the approach to right heart disease by emphasizing factors that regulate the transition from adaptive to maladaptive right ventricular-pulmonary vascular (patho)physiology.
Ryan, Justin R; Chen, Tsinsue; Nakaji, Peter; Frakes, David H; Gonzalez, L Fernando
2015-11-01
Educational simulators provide a means for students and experts to learn and refine surgical skills. Educators can leverage the strengths of medical simulators to effectively teach complex and high-risk surgical procedures, such as placement of an external ventricular drain. Our objective was to develop a cost-effective, patient-derived medical simulacrum for cerebral lateral ventriculostomy. A cost-effective, patient-derived medical simulacrum was developed for placement of an external lateral ventriculostomy. Elastomeric and gel casting techniques were used to achieve realistic brain geometry and material properties. 3D printing technology was leveraged to develop accurate cranial properties and dimensions. An economical, gravity-driven pump was developed to provide normal and abnormal ventricular pressures. A small pilot study was performed to gauge simulation efficacy using a technology acceptance model. An accurate geometric representation of the brain was developed with independent lateral cerebral ventricular chambers. A gravity-driven pump pressurized the ventricular cavities to physiologic values. A qualitative study illustrated that the simulation has potential as an educational tool to train medical professionals in the ventriculostomy procedure. The ventricular simulacrum can improve learning in a medical education environment. Rapid prototyping and multi-material casting techniques can produce patient-derived models for cost-effective and realistic surgical training scenarios. Copyright © 2015 Elsevier Inc. All rights reserved.
Liu, Yunbo; Wear, Keith A; Harris, Gerald R
2017-10-01
Reliable acoustic characterization is fundamental for patient safety and clinical efficacy during high-intensity therapeutic ultrasound (HITU) treatment. Technical challenges, such as measurement variation and signal analysis, still exist for HITU exposimetry using ultrasound hydrophones. In this work, four hydrophones were compared for pressure measurement: a robust needle hydrophone, a small polyvinylidene fluoride capsule hydrophone and two fiberoptic hydrophones. The focal waveform and beam distribution of a single-element HITU transducer (1.05 MHz and 3.3 MHz) were evaluated. Complex deconvolution between the hydrophone voltage signal and frequency-dependent complex sensitivity was performed to obtain pressure waveforms. Compressional pressure (p + ), rarefactional pressure (p - ) and focal beam distribution were compared up to 10.6/-6.0 MPa (p + /p - ) (1.05 MHz) and 20.65/-7.20 MPa (3.3 MHz). The effects of spatial averaging, local non-linear distortion, complex deconvolution and hydrophone damage thresholds were investigated. This study showed a variation of no better than 10%-15% among hydrophones during HITU pressure characterization. Published by Elsevier Inc.
Clinical review: Positive end-expiratory pressure and cardiac output
Luecke, Thomas; Pelosi, Paolo
2005-01-01
In patients with acute lung injury, high levels of positive end-expiratory pressure (PEEP) may be necessary to maintain or restore oxygenation, despite the fact that 'aggressive' mechanical ventilation can markedly affect cardiac function in a complex and often unpredictable fashion. As heart rate usually does not change with PEEP, the entire fall in cardiac output is a consequence of a reduction in left ventricular stroke volume (SV). PEEP-induced changes in cardiac output are analyzed, therefore, in terms of changes in SV and its determinants (preload, afterload, contractility and ventricular compliance). Mechanical ventilation with PEEP, like any other active or passive ventilatory maneuver, primarily affects cardiac function by changing lung volume and intrathoracic pressure. In order to describe the direct cardiocirculatory consequences of respiratory failure necessitating mechanical ventilation and PEEP, this review will focus on the effects of changes in lung volume, factors controlling venous return, the diastolic interactions between the ventricles and the effects of intrathoracic pressure on cardiac function, specifically left ventricular function. Finally, the hemodynamic consequences of PEEP in patients with heart failure, chronic obstructive pulmonary disease and acute respiratory distress syndrome are discussed. PMID:16356246
Periodic oscillation of intracranial pressure in ventricular dilation: a preliminary report.
Kuchiwaki, H; Misu, N; Kageyama, N; Ishiguri, H; Takada, S
1987-12-01
Artificial pressure waves (PWs) were generated by manual inflation of a balloon in the trigonum of the lateral ventricle in seven adult mongrel dogs with normal cerebrospinal fluid (CSF) circulation. In 14 of 16 series of continuous appearances of artificial PWs, local shifts of the brain were successfully monitored using small strain-gauge sensors at the periventricular structures in these animals. Of the 14 series, 13 showed displacements of the periventricular structures, suggesting ventricular dilation. These results did not always correlate with macroscopic findings. They are thought to be due largely to periventricular oedemas and, in part, non-uniform dilations of the ventricles during PWs. We conclude that a water hammer formed by reflection of an increased pulse pressure of PWs at the site of CSF absorption causes a shift of CSF from the ventricle to the periventricular structures through the wall of the ventricle. This phenomenon appears amplified in patients with impaired CSF absorption. Thus, PWs have a pathological role in the progress of ventricular dilation in patients with normal pressure hydrocephalus.
Lala, Radu Ioan; Darabantiu, Dan; Pilat, Luminita; Puschita, Maria
2016-02-01
Heart failure is accompanied by abnormalities in ventricular-vascular interaction due to increased myocardial and arterial stiffness. Galectin-3 is a recently discovered biomarker that plays an important role in myocardial and vascular fibrosis and heart failure progression. The aim of this study was to determine whether galectin-3 is correlated with arterial stiffening markers and impaired ventricular-arterial coupling in decompensated heart failure patients. A total of 79 inpatients with acute decompensated heart failure were evaluated. Serum galectin-3 was determined at baseline, and during admission, transthoracic echocardiography and measurements of vascular indices by Doppler ultrasonography were performed. Elevated pulse wave velocity and low arterial carotid distensibility are associated with heart failure in patients with preserved ejection fraction (p = 0.04, p = 0.009). Pulse wave velocity, carotid distensibility and Young's modulus did not correlate with serum galectin-3 levels. Conversely, raised galectin-3 levels correlated with an increased ventricular-arterial coupling ratio (Ea/Elv) p = 0.047, OR = 1.9, 95% CI (1.0‑3.6). Increased galectin-3 levels were associated with lower rates of left ventricular pressure rise in early systole (dp/dt) (p=0.018) and raised pulmonary artery pressure (p = 0.046). High galectin-3 levels (p = 0.038, HR = 3.07) and arterial pulmonary pressure (p = 0.007, HR = 1.06) were found to be independent risk factors for all-cause mortality and readmissions. This study showed no significant correlation between serum galectin-3 levels and arterial stiffening markers. Instead, high galectin-3 levels predicted impaired ventricular-arterial coupling. Galectin-3 may be predictive of raised pulmonary artery pressures. Elevated galectin-3 levels correlate with severe systolic dysfunction and together with pulmonary hypertension are independent markers of outcome.
Cornwell, William K; Tarumi, Takashi; Stickford, Abigail; Lawley, Justin; Roberts, Monique; Parker, Rosemary; Fitzsimmons, Catherine; Kibe, Julius; Ayers, Colby; Markham, David; Drazner, Mark H; Fu, Qi; Levine, Benjamin D
2015-12-15
Current-generation left ventricular assist devices provide circulatory support that is minimally or entirely nonpulsatile and are associated with marked increases in muscle sympathetic nerve activity (MSNA), likely through a baroreceptor-mediated pathway. We sought to determine whether the restoration of pulsatile flow through modulations in pump speed would reduce MSNA through the arterial baroreceptor reflex. Ten men and 3 women (54 ± 14 years) with Heartmate II continuous-flow left ventricular assist devices underwent hemodynamic and sympathetic neural assessment. Beat-to-beat blood pressure, carotid ultrasonography at the level of the arterial baroreceptors, and MSNA via microneurography were continuously recorded to determine steady-state responses to step changes (200-400 revolutions per minute) in continuous-flow left ventricular assist device pump speed from a maximum of 10,480 ± 315 revolutions per minute to a minimum of 8500 ± 380 revolutions per minute. Reductions in pump speed led to increases in pulse pressure (high versus low speed: 17 ± 7 versus 26 ± 12 mm Hg; P<0.01), distension of the carotid artery, and carotid arterial wall tension (P<0.05 for all measures). In addition, MSNA was reduced (high versus low speed: 41 ± 15 versus 33 ± 16 bursts per minute; P<0.01) despite a reduction in mean arterial pressure and was inversely related to pulse pressure (P=0.037). Among subjects with continuous-flow left ventricular assist devices, the restoration of pulsatile flow through modulations in pump speed leads to increased distortion of the arterial baroreceptors with a subsequent decline in MSNA. Additional study is needed to determine whether reduction of MSNA in this setting leads to improved outcomes. © 2015 American Heart Association, Inc.
Ramage, Andrew G; de Burgh Daly, M
1998-01-01
Experiments were carried out to determine the effects of the application of the selective 5-HT2 receptor agonist DOI intravenously (in the presence of the peripherally acting 5-HT2 receptor antagonist, BW501C67, 1 mg kg−1, i.v.) or to the `glycine sensitive area' of the ventral surface (30 μg each side) on the left ventricular inotropic (left ventricular dP/dt max) and vascularly isolated hindlimb responses in anaesthetized cats. For the ventral surface experiments, NMDA (10 μg each side) was applied to act as a positive control. In all experiments heart rate and mean arterial blood pressure were held constant to exclude any secondary effects caused by changes in these variables.DOI (n=6) i.v or on the ventral surface had no effect on left ventricular dP/dt max but caused a significant increase in hindlimb perfusion pressure of 40±9 and 50±14 mmHg, respectively. Respiration was unaffected. NMDA (n=6), applied to the ventral surface, caused significant increases in both left ventricular dP/dt max and hindlimb perfusion pressure of 1950±349 mmHg s−1 and 69±17 mmHg respectively, with no associated change in left ventricular end-diastolic pressure. The amplitude of respiratory movements increased.It is concluded that activation of 5-HT2 receptors at the level of the rostral ventrolateral medulla (RVLM) excites sympathetic premotor neurons and/or their antecedents controlling hindlimb vascular resistance but not those controlling the inotropic effects on the left ventricle. PMID:9863644
Atluri, Pavan; Fairman, Alexander S.; MacArthur, John W.; Goldstone, Andrew B.; Cohen, Jeffrey E.; Howard, Jessica L.; Zalewski, Christyna M.; Shudo, Yasuhiro; Woo, Y. Joseph
2014-01-01
Background Continuous flow left ventricular assist devices (CF LVAD) are being implanted with increasing frequency for end-stage heart failure. At the time of LVAD implant, a large proportion of patients have pulmonary hypertension, right ventricular (RV) dysfunction, and tricuspid regurgitation (TR). RV dysfunction and TR can exacerbate renal dysfunction, hepatic dysfunction, coagulopathy, edema, and even prohibit isolated LVAD implant. Repairing TR mandates increased cardiopulmonary bypass time and bicaval cannulation, which should be reserved for the time of orthotopic heart transplantation. We hypothesized that CF LVAD implant would improve pulmonary artery pressures, enhance RV function, and minimize TR, obviating need for surgical tricuspid repair. Methods One hundred fourteen continuous flow LVADs implanted from 2005 through 2011 at a single center, with medical management of functional TR, were retrospectively analyzed. Pulmonary artery pressures were measured immediately prior to and following LVAD implant. RV function and TR were graded according to standard echocardiographic criteria, prior to, immediately following, and long-term following LVAD. Results There was a significant improvement in post-VAD mean pulmonary arterial pressures (26.6 ± 4.9 vs. 30.2 ± 7.4 mmHg, p = 0.008) with equivalent loading pressures (CVP = 12.0 ± 4.0 vs. 12.1 ± 5.1 p = NS). RV function significantly improved, as noted by right ventricular stroke work index (7.04 ± 2.60 vs. 6.05 ± 2.54, p = 0.02). There was an immediate improvement in TR grade and RV function following LVAD implant, which was sustained long term. Conclusion Continuous flow LVAD implant improves pulmonary hypertension, RV function, and tricuspid regurgitation. TR may be managed nonoperatively during CF LVAD implant. PMID:24118109
Lung assist devices influence cardio-energetic parameters: Numerical simulation study.
De Lazzari, C; Quatember, B; Recheis, W; Mayr, M; Demertzis, S; Allasia, G; De Rossi, A; Cavoretto, R; Venturino, E; Genuini, I
2015-08-01
We aim at an analysis of the effects mechanical ventilators (MVs) and thoracic artificial lungs (TALs) will have on the cardiovascular system, especially on important quantities, such as left and right ventricular external work (EW), pressure-volume area (PVA) and cardiac mechanical efficiency (CME). Our analyses are based on simulation studies which were carried out by using our CARDIOSIM(©) software simulator. At first, we carried out simulation studies of patients undergoing mechanical ventilation (MV) without a thoracic artificial lung (TAL). Subsequently, we conducted simulation studies of patients who had been provided with a TAL, but did not undergo MV. We aimed at describing the patient's physiological characteristics and their variations with time, such as EW, PVA, CME, cardiac output (CO) and mean pulmonary arterial/venous pressure (PAP/PVP). We were starting with a simulation run under well-defined initial conditions which was followed by simulation runs for a wide range of mean intrathoracic pressure settings. Our simulations of MV without TAL showed that for mean intrathoracic pressure settings from negative (-4 mmHg) to positive (+5 mmHg) values, the left and right ventricular EW and PVA, right ventricular CME and CO decreased, whereas left ventricular CME and the PAP increased. The simulation studies of patients with a TAL, comprised all the usual TAL arrangements, viz. configurations "in series" and in parallel with the natural lung and, moreover, hybrid configurations. The main objective of the simulation studies was, as before, the assessment of the hemodynamic response to the application of a TAL. We could for instance show that, in case of an "in series" configuration, a reduction (an increase) in left (right) ventricular EW and PVA values occurred, whereas the best performance in terms of CO can be achieved in the case of an in parallel configuration.
Keshavarz-Motamed, Zahra; Nezami, Farhad Rikhtegar; Partida, Ramon A.; Nakamura, Kenta; Staziaki, Pedro Vinícius; Ben-Assa, Eyal; Ghoshhajra, Brian; Bhatt, Ami B.; Edelman, Elazer R.
2017-01-01
OBJECTIVES To investigate the impact of transcatheter intervention on left ventricular (LV) function and aortic hemodynamics in patients with mild coarctation of the aorta (COA). BACKGROUND The optimal method and timing of transcatheter intervention for COA remains unclear, especially when the severity of COA is mild (peak-to-peak trans-coarctation pressure gradient, PKdP < 20 mmHg). Debate rages regarding the risk/benefit ratio of intervention vs. long-term effects of persistent minimal gradient in this heterogeneous population with differing blood pressures, ventricular function and peripheral perfusion. METHODS We developed a unique computational fluid dynamics and lumped parameter modeling framework based on patient-specific hemodynamic input parameters and validated it against patient-specific clinical outcomes (pre- and post-intervention). We used clinically measured hemodynamic metrics and imaging of the aorta and the LV in thirty-four patients with mild COA to make these correlations. RESULTS Despite dramatic reduction in trans-coarctation pressure gradient (catheter and Doppler echocardiography pressure gradients reduced 75% and 47.3%,), there was only modest effect on aortic flow and no significant impact on aortic shear stress (maximum time-averaged wall shear stress in descending aorta was reduced 5.1%). In no patient did transcatheter intervention improve LV function (e.g., stroke work and normalized stroke work were reduced by only 4.48% and 3.9%). CONCLUSIONS Transcatheter intervention which successfully relieves mild COA pressure gradients does not translate to decrease myocardial strain. The effects of intervention were determined to the greatest degree by ventricular-vascular coupling hemodynamics, and provide a novel valuable mechanism to evaluate patients with COA which may influence clinical practice. PMID:27659574
Hyldebrandt, Janus Adler; Sivén, Eleonora; Agger, Peter; Frederiksen, Christian Alcaraz; Heiberg, Johan; Wemmelund, Kristian Borup; Ravn, Hanne Berg
2015-07-01
Right ventricular (RV) failure due to chronic pressure overload is a main determinant of outcome in congenital heart disease. Medical management is challenging because not only contractility but also the interventricular relationship is important for increasing cardiac output. This study evaluated the effect of milrinone alone and in combination with epinephrine or dopamine on hemodynamics, ventricular performance, and the interventricular relationship. RV failure was induced in 21 Danish landrace pigs by pulmonary artery banding. After 10 wk, animals were reexamined using biventricular pressure-volume conductance catheters. The maximum pressure in the RV increased by 113% (P < 0.0001) and end-diastolic volume by 43% (P < 0.002), while left ventricular (LV) pressure simultaneously decreased (P = 0.006). Concomitantly, mean arterial pressure (MAP; -16%, P = 0.01), cardiac index (CI; -23%, P < 0.0001), and mixed venous oxygen saturation (SvO2 ; -40%, P < 0.0001) decreased. Milrinone increased CI (11%, P = 0.008) and heart rate (HR; 21%, P < 0.0001). Stroke volume index (SVI) decreased (7%, P = 0.03), although RV contractility was improved. The addition of either epinephrine or dopamine further increased CI and HR in a dose-dependent manner but without any significant differences between the two interventions. A more pronounced increase in biventricular contractility was observed in the dopamine-treated animals. LV volume was reduced in both the dopamine and epinephrine groups with increasing doses In the failing pressure overloaded RV, milrinone improved CI and increased contractility. Albeit additional dose-dependent effects of both epinephrine and dopamine on CI and contractility, neither of the interventions improved SVI due to reduced filling of the LV. Copyright © 2015 the American Physiological Society.
Oxidative stress is associated with increased pulmonary artery systolic pressure in humans.
Ghasemzadeh, Nima; Patel, Riyaz S; Eapen, Danny J; Veledar, Emir; Al Kassem, Hatem; Manocha, Pankaj; Khayata, Mohamed; Zafari, A Maziar; Sperling, Laurence; Jones, Dean P; Quyyumi, Arshed A
2014-06-01
Oxidative stress contributes to the development of pulmonary hypertension in experimental models, but this association in humans is unknown. We investigated the relationship between pulmonary artery systolic pressure measured by echocardiography and plasma aminothiol oxidative stress markers, with the hypothesis that oxidative stress will be higher in those with pulmonary hypertension. A group of 347 patients aged 65±12 years from the Emory Cardiovascular Biobank underwent echocardiographic assessment of left ventricular ejection fraction and pulmonary artery systolic pressure. Plasma aminothiols, cysteine, its oxidized form, cystine, glutathione, and its oxidized disulphide were measured and the redox potentials (Eh) of cysteine/cystine and glutathione/oxidized glutathione couples were calculated. Non-normally distributed variables were log transformed (Ln). Univariate predictors of pulmonary artery systolic pressure included age (P<0.001), sex (P=0.002), mitral regurgitation (P<0.001), left ventricular ejection fraction (P<0.001), left atrial size (P<0.001), diabetes mellitus (P=0.03), plasma Ln cystine (β=9.53; P<0.001), Ln glutathione (β=-5.4; P=0.002), and Eh glutathione (β=0.21; P=0.001). A multivariate linear regression model adjusting for all confounding variables demonstrated that Ln cystine (β=6.56; P=0.007), mitral regurgitation (β=4.52; P<0.001), statin use (β=-3.39; P=0.03), left ventricular ejection fraction (β=-0.26; P=0.003), and age (β=0.17; P=0.003) were independent predictors of pulmonary artery systolic pressure. For each 1% increase in plasma cystine, pulmonary artery systolic pressure increased by 16%. This association persisted in the subgroup with preserved left ventricular ejection fraction (≥50%) and no significant mitral regurgitation. Whether treatment of oxidative stress will improve pulmonary hypertension requires further study.
Kamran, Haroon; Salciccioli, Louis; Pushilin, Sergei; Kumar, Paraag; Carter, John; Kuo, John; Novotney, Carol; Lazar, Jason M
2011-01-01
Nonhuman primates are used frequently in cardiovascular research. Cardiac time intervals derived by phonocardiography have long been used to assess left ventricular function. Electronic stethoscopes are simple low-cost systems that display heart sound signals. We assessed the use of an electronic stethoscope to measure cardiac time intervals in 48 healthy bonnet macaques (age, 8 ± 5 y) based on recorded heart sounds. Technically adequate recordings were obtained from all animals and required 1.5 ± 1.3 min. The following cardiac time intervals were determined by simultaneously recording acoustic and single-lead electrocardiographic data: electromechanical activation time (QS1), electromechanical systole (QS2), the time interval between the first and second heart sounds (S1S2), and the time interval between the second and first sounds (S2S1). QS2 was correlated with heart rate, mean arterial pressure, diastolic blood pressure, and left ventricular ejection time determined by using echocardiography. S1S2 correlated with heart rate, mean arterial pressure, diastolic blood pressure, left ventricular ejection time, and age. S2S1 correlated with heart rate, mean arterial pressure, diastolic blood pressure, systolic blood pressure, and left ventricular ejection time. QS1 did not correlate with any anthropometric or echocardiographic parameter. The relation S1S2/S2S1 correlated with systolic blood pressure. On multivariate analyses, heart rate was the only independent predictor of QS2, S1S2, and S2S1. In conclusion, determination of cardiac time intervals is feasible and reproducible by using an electrical stethoscope in nonhuman primates. Heart rate is a major determinant of QS2, S1S2, and S2S1 but not QS1; regression equations for reference values for cardiac time intervals in bonnet macaques are provided. PMID:21439218
1991-01-01
Depolarization-activated outward K+ currents in isolated adult rat ventricular myocytes were characterized using the whole-cell variation of the patch-clamp recording technique. During brief depolarizations to potentials positive to -40 mV, Ca(2+)-independent outward K+ currents in these cells rise to a transient peak, followed by a slower decay to an apparent plateau. The analyses completed here reveal that the observed outward current waveforms result from the activation of two kinetically distinct voltage-dependent K+ currents: one that activates and inactivates rapidly, and one that activates and inactivates slowly, on membrane depolarization. These currents are referred to here as Ito (transient outward) and IK (delayed rectifier), respectively, because their properties are similar (although not identical) to these K+ current types in other cells. Although the voltage dependences of Ito and IK activation are similar, Ito activates approximately 10-fold and inactivates approximately 30-fold more rapidly than IK at all test potentials. In the composite current waveforms measured during brief depolarizations, therefore, the peak current predominantly reflects Ito, whereas IK is the primary determinant of the plateau. There are also marked differences in the voltage dependences of steady-state inactivation of these two K+ currents: IK undergoes steady-state inactivation at all potentials positive to -120 mV, and is 50% inactivated at -69 mV; Ito, in contrast, is insensitive to steady-state inactivation at membrane potentials negative to -50 mV. In addition, Ito recovers from steady-state inactivation faster than IK: at -90 mV, for example, approximately 70% recovery from the inactivation produced at -20 mV is observed within 20 ms for Ito; IK recovers approximately 25-fold more slowly. The pharmacological properties of Ito and IK are also distinct: 4-aminopyridine preferentially attenuates Ito, and tetraethylammonium suppresses predominantly IK. The voltage- and time- dependent properties of these currents are interpreted here in terms of a model in which Ito underlies the initial, rapid repolarization phase of the action potential (AP), and IK is responsible for the slower phase of AP repolarization back to the resting membrane potential, in adult rat ventricular myocytes. PMID:1865177
Ohyu, Shigeharu; Okamoto, Yoshiwo; Kuriki, Shinya
2002-06-01
A novel magnetocardiographic inverse method for reconstructing the action potential amplitude (APA) and the activation time (AT) on the ventricular myocardium is proposed. This method is based on the propagated excitation model, in which the excitation is propagated through the ventricle with nonuniform height of action potential. Assumption of stepwise waveform on the transmembrane potential was introduced in the model. Spatial gradient of transmembrane potential, which is defined by APA and AT distributed in the ventricular wall, is used for the computation of a current source distribution. Based on this source model, the distributions of APA and AT are inversely reconstructed from the QRS interval of magnetocardiogram (MCG) utilizing a maximum a posteriori approach. The proposed reconstruction method was tested through computer simulations. Stability of the methods with respect to measurement noise was demonstrated. When reference APA was provided as a uniform distribution, root-mean-square errors of estimated APA were below 10 mV for MCG signal-to-noise ratios greater than, or equal to, 20 dB. Low-amplitude regions located at several sites in reference APA distributions were correctly reproduced in reconstructed APA distributions. The goal of our study is to develop a method for detecting myocardial ischemia through the depression of reconstructed APA distributions.
Honda, Atsushi; Nakamura, Yuji; Ohara, Hiroshi; Cao, Xin; Nomura, Hiroaki; Katagi, Jun; Wada, Takeshi; Izumi-Nakaseko, Hiroko; Ando, Kentaro; Sugiyama, Atsushi
2016-03-15
Cardiac effects of a prostagrandin EP4-receptor agonist ONO-AE1-329 were assessed in the halothane-anesthetized dogs under the monitoring of left ventricular pressure-volume relationship, which were compared with those of clinically recommended doses of dopamine, dobutamine and milrinone (n=4-5 for each treatment). ONO-AE1-329 was intravenously administered in doses of 0.3, 1 and 3 ng/kg/min for 10 min with a pause of 20 min. Dopamine in a dose of 3 µg/kg/min for 10 min, dobutamine in a dose of 1 µg/kg/min for 10 min and milrinone in a dose of 5 µg/kg/min for 10 min followed by 0.5 µg/kg/min for 10 min were intravenously administered. Low dose of ONO-AE1-329 increased the stroke volume. Middle dose of ONO-AE1-329 increased the cardiac output, left ventricular end-diastolic volume, ejection fraction, maximum upstroke/downstroke velocities of the left ventricular pressure and external work, but decreased the end-systolic pressure and internal work besides the change by the low dose. High dose of ONO-AE1-329 increased the heart rate and maximum elastance, but decreased the end-systolic volume besides the changes by the middle dose. Dopamine, dobutamine and milrinone exerted essentially similar cardiac effects to ONO-AE1-329, but they did not significantly change the end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, end-systolic pressure, maximum elastance, external work or internal work. Thus, EP4-receptor stimulation by ONO-AE1-329 may have potential to better promote the passive ventricular filling than the conventional cardiotonic drugs, which could become a candidate of novel therapeutic strategy for the treatment of heart failure with preserved ejection fraction. Copyright © 2016 Elsevier B.V. All rights reserved.
Perioperative management of calves undergoing implantation of a left ventricular assist device.
Wilson, D V; Kantrowitz, A; Pacholewicz, J; Salat, O; Paules, B R; Zhou, Y; Dawe, E J
2000-01-01
To describe perioperative management of calves that underwent left lateral thoracotomy, aortic cross-clamping, partial left heart bypass and implantation of a left ventricular assist device. A total of 43 healthy castrated male calves, weighing 121 +/- 24 kg. Diazepam (mean +/- SD, 0.26 +/- 0.07 mg/kg), ketamine (5.9 +/- 2.17 mg/kg) and isoflurane were used in the anesthetic management of calves undergoing implantation of a left ventricular assist device in the descending thoracic aorta. Other adjunctive agents administered were fentanyl (11 +/- 5.4 microg/kg), lidocaine (4.9 +/- 3.19 mg/kg), bupivacaine (0.75%) and butorphanol (0.49 +/- 0.13 mg/kg). None of the calves regurgitated at induction or during intubation. A tube was used to drain the rumen and prevent bloat during the procedure. Partial left heart bypass was used to perfuse the caudal half of the body during the period of aortic cross clamp and device implantation. Initial mean systemic blood pressure was 96 +/- 25 mm Hg, and pressures measured in the auricular artery increased during aortic cross-clamping and bypass. Vasoconstrictor therapy was required to treat caudal arterial hypotension during the procedure in 9 calves. Mean systemic arterial pressures returned to baseline values by the end of the anesthetic period. Initial mean pulmonary arterial pressures (PAP) were 22 +/- 3 mm Hg. A significant but transient increase in pulmonary arterial pressure occurred after both heparin and protamine administration. The described anesthetic protocol was effective for thoracotomy and implantation of an intra-aortic left ventricular assist device in normal calves. Partial left ventricular bypass was a useful adjunct during the period of aortic cross clamp. The doses of heparin and protamine administered were effective. Responsibility to monitor oxygenation of the cranial half of the animal continues during the bypass period as hypoxemia due to pulmonary dysfunction will not be detected by the perfusionist.
Nekooeian, Ali A; Tabrizchi, Reza
1998-01-01
The effects of CGS 21680, a selective A2A adenosine receptor agonist, on cardiac output, blood pressure, mean circulatory filling pressure (Pmcf), arterial and venous resistances, heart rate and left ventricular end-diastolic pressure were assessed in rats with acute heart failure by means of coronary artery occlusion.Animals (n=6 in each group) were divided into five groups: group I, sham-operated vehicle-treated (0.9% saline; 0.018 mL min−1); groups II-V, subject to coronary artery occlusion and treated with vehicle (0.9% saline; 0.018 ml min−1) and CGS 21680 (0.1, 0.3 and 1.0 μg kg−1 min−1), respectively. Haemodynamic measurements were taken one hour after completion of surgery, ninety minutes after coronary artery occlusion (except in group I), and fifteen minutes after infusion of saline or CGS 21680.Baseline haemodynamic measurements before occlusion were found not to differ significantly between the different groups of animals. However, after occlusion, cardiac output, rate of rise in left ventricular pressure (+dP/dt) and blood pressure were significantly reduced when compared to corresponding values in sham-operated animals. In addition, occlusion of the coronary artery resulted in a significant elevation in venous resistance, Pmcf and left ventricular end-diastolic pressure as compared to corresponding values in sham-operated animals.Infusion with CGS 21680 at the highest dose significantly reduced blood pressure, arterial resistance and left ventricular end-diastolic pressure when compared to occluded vehicle-treated animals (group II). Administration of CGS 21680 at the highest dose also significantly increased cardiac output (28%) and heart rate (10%) in comparison to occluded vehicle-treated animals. In addition, the highest dose of CGS 21680 significantly reduced Pmcf (9%) and venous resistance (62%) in comparison to occluded vehicle-treated animals. Administration of CGS 21680 did not significantly affect +dP/dt when compared to occluded vehicle-treated animals.The results from the present investigation indicate that occlusion of the coronary artery in rats results in a state of heart failure characterized by reduced arterial pressure and cardiac output, and increased venous resistance, Pmcf and left ventricular end-diastolic pressure. Administration of CGS 21680 to animals with acute heart failure resulted in increased cardiac output which was due to reduced venous resistance, as well as increased heart rate. PMID:9605574
Nekooeian, A A; Tabrizchi, R
1998-04-01
1. The effects of CGS 21680, a selective A2A adenosine receptor agonist, on cardiac output, blood pressure, mean circulatory filling pressure (Pmcf), arterial and venous resistances, heart rate and left ventricular end-diastolic pressure were assessed in rats with acute heart failure by means of coronary artery occlusion. 2. Animals (n=6 in each group) were divided into five groups: group I, sham-operated vehicle-treated (0.9% saline; 0.018 mL min(-1)); groups II-V, subject to coronary artery occlusion and treated with vehicle (0.9% saline; 0.018 ml min(-1)) and CGS 21680 (0.1, 0.3 and 1.0 microg kg(-1) min(-1)), respectively. Haemodynamic measurements were taken one hour after completion of surgery, ninety minutes after coronary artery occlusion (except in group I), and fifteen minutes after infusion of saline or CGS 21680. 3. Baseline haemodynamic measurements before occlusion were found not to differ significantly between the different groups of animals. However, after occlusion, cardiac output, rate of rise in left ventricular pressure (+ dP/dt) and blood pressure were significantly reduced when compared to corresponding values in sham-operated animals. In addition, occlusion of the coronary artery resulted in a significant elevation in venous resistance, Pmcf and left ventricular end-diastolic pressure as compared to corresponding values in sham-operated animals. 4. Infusion with CGS 21680 at the highest dose significantly reduced blood pressure, arterial resistance and left ventricular end-diastolic pressure when compared to occluded vehicle-treated animals (group II). Administration of CGS 21680 at the highest dose also significantly increased cardiac output (28%) and heart rate (10%) in comparison to occluded vehicle-treated animals. In addition, the highest dose of CGS 21680 significantly reduced Pmcf (9%) and venous resistance (62%) in comparison to occluded vehicle-treated animals. Administration of CGS 21680 did not significantly affect +dP/dt when compared to occluded vehicle-treated animals. 5. The results from the present investigation indicate that occlusion of the coronary artery in rats results in a state of heart failure characterized by reduced arterial pressure and cardiac output, and increased venous resistance, Pmcf and left ventricular end-diastolic pressure. Administration of CGS 21680 to animals with acute heart failure resulted in increased cardiac output which was due to reduced venous resistance, as well as increased heart rate.
Burattini, R; Sipkema, P; van Huis, G A; Westerhof, N
1985-01-01
This study was performed to elucidate the effects of cardiac contraction on coronary pressure-flow relations. On the basis of the waterfall mechanism, a lumped model of the coronary arterial system is presented consisting of a proximal (epicardial) compliance, a coronary resistance, and an intramyocardial compliance. A "back"-pressure, assumed to be proportional (constant k) to left ventricular pressure, impedes flow. From steady-state measurements of circumflex coronary artery flow and inflow pressure, together with left ventricular pressure, the values of the three model parameters and the constant k have been estimated. In the control condition proximal compliance is found to be 1.7 X 10(-12) m4s2kg-1, intramyocardial compliance 110 X 10(-12)m4s2kg-1, and resistance 7.5 X 10(9) kgm-4s-1. The proportionality constant k is close to unity. Effects of changes in left ventricular pressure and inflow pressure and the effect of vasoactive drugs on the parameters are also investigated. Changes in coronary resistance are always opposite to changes in intramyocardial compliance. Sensitivity analysis showed that epicardial compliance plays its major role during isovolumic contraction and relaxation; resistance plays a role throughout the cardiac cycle but is more important in diastole than in systole, whereas intramyocardial compliance plays a role in systole and in early diastole.
Nomura, Hiroaki; Nakamura, Yuji; Cao, Xin; Honda, Atsushi; Katagi, Jun; Ohara, Hiroshi; Izumi-Nakaseko, Hiroko; Satoh, Yoshioki; Ando, Kentaro; Sugiyama, Atsushi
2015-08-15
Cardiovascular effects of a highly selective prostaglandin E2 type 4 (EP4) receptor agonist ONO-AE1-329 were assessed with the halothane-anesthetized dogs (n=6). ONO-AE1-329 was intravenously infused in three escalating doses of 0.3, 1 and 3ng/kg/min for 10min with a pause of 20min between the doses. The low dose of 0.3ng/kg/min significantly increased maximum upstroke velocity of left ventricular pressure by 18% at 20min, indicating increase of ventricular contractility. The middle dose of 1ng/kg/min significantly decreased total peripheral resistance by 24% and left ventricular end-diastolic pressure by 32% at 10min, indicating dilation of arteriolar resistance vessels and venous capacitance ones, respectively; and increased cardiac output by 25% at 10min in addition to the change induced by the low dose. The high dose of 3ng/kg/min increased heart rate by 34% at 10min; decreased mean blood pressure by 14% at 10min and atrioventricular nodal conduction time by 13% at 5min; and shortened left ventricular systolic period by 8% at 10min and electromechanical coupling defined as an interval from completion of repolarization to the start of ventricular diastole by 39% at 10min in addition to the changes induced by the middle dose. No significant change was detected in a ventricular repolarization period. These results indicate that ONO-AE1-329 may possess a similar cardiovascular profile to typical phosphodiesterase 3 inhibitors as an inodilator, and suggest that EP4 receptor stimulation can become an alternative strategy for the treatment of congestive heart failure. Copyright © 2015 Elsevier B.V. All rights reserved.
Ng, Boon C.; Timms, Daniel; Cohn, William E.
2018-01-01
Despite the widespread acceptance of rotary blood pump (RBP) in clinical use over the past decades, the diminished flow pulsatility generated by a fixed speed RBP has been regarded as a potential factor that may lead to adverse events such as vasculature stiffening and hemorrhagic strokes. In this study, we investigate the feasibility of generating physiological pulse pressure in the pulmonary circulation by modulating the speed of a right ventricular assist device (RVAD) in a mock circulation loop. A rectangular pulse profile with predetermined pulse width has been implemented as the pump speed pattern with two different phase shifts (0% and 50%) with respect to the ventricular contraction. In addition, the performance of the speed modulation strategy has been assessed under different cardiovascular states, including variation in ventricular contractility and pulmonary arterial compliance. Our results indicated that the proposed pulse profile with optimised parameters (Apulse = 10000 rpm and ωmin = 3000 rpm) was able to generate pulmonary arterial pulse pressure within the physiological range (9–15 mmHg) while avoiding undesirable pump backflow under both co- and counter-pulsation modes. As compared to co-pulsation, stroke work was reduced by over 44% under counter-pulsation, suggesting that mechanical workload of the right ventricle can be efficiently mitigated through counter-pulsing the pump speed. Furthermore, our results showed that improved ventricular contractility could potentially lead to higher risk of ventricular suction and pump backflow, while stiffening of the pulmonary artery resulted in increased pulse pressure. In conclusion, the proposed speed modulation strategy produces pulsatile hemodynamics, which is more physiologic than continuous blood flow. The findings also provide valuable insight into the interaction between RVAD speed modulation and the pulmonary circulation under various cardiovascular states. PMID:29677212
Palazzuoli, Alberto; Silverberg, Donald S; Calabrò, Anna; Spinelli, Tommaso; Quatrini, Ilaria; Campagna, Maria S; Franci, Beatrice; Nuti, Ranuccio
2009-06-01
Anemia in heart failure is related to advanced New York Heart Association classes, severe systolic dysfunction, and reduced exercise tolerance. Although anemia is frequently found in congestive heart failure (CHF), little is known about the effect of its' correction with erythropoietin (EPO) on cardiac structure and function. The present study examines, in patients with advanced CHF and anemia, the effects of beta-EPO on left ventricular volumes, left ventricular ejection fraction (LVEF), left and right longitudinal function mitral anular plane systolic excursion (MAPSE), tricuspid anular plane excursion (TAPSE), and pulmonary artery pressures in 58 patients during 1-year follow-up in a double-blind controlled study of correction of anemia with subcutaneous beta-EPO. Echocardiographic evaluation, B-Type natriuretic peptide (BNP) levels, and hematological parameters are reported at 4 and 12 months. The patients in group A after 4 months of follow-up period demonstrated an increase in LVEF and MAPSE (P < 0.05 and P < 0.01, respectively) with left ventricular systolic volume reduction (P < 0.02) with respect to baseline and controls. After 12 months, results regarding left ventricular systolic volume LVEF and MAPSE persisted (P < 0.001). In addition, TAPSE increased and pulmonary artery pressures fell significantly in group A (P < 0.01). All these changes occurred together with a significant BNP reduction and significant hemoglobin increase in the treated group. Therefore, we revealed a reduced hospitalization rate in treated patients with respect to the controls (25% in treated vs. 54% in controls). In patients with anemia and CHF, correction of anemia with beta-EPO and oral iron over 1 year leads to an improvement in left and right ventricular systolic function by reducing cardiac remodeling, BNP levels, and hospitalization rate.
Pizzuto, Matthew F; Suzuki, Gen; Banas, Michael D; Heavey, Brendan; Fallavollita, James A; Canty, John M
2013-06-15
Many survivors of sudden cardiac death (SCD) have normal global ventricular function and severe coronary artery disease but no evidence of symptomatic ischemia or infarction before the development of lethal ventricular arrhythmias, and the trigger for ventricular tachycardia (VT)/ventricular fibrillation (VF) remains unclear. We sought to identify the role of spontaneous ischemia and temporal hemodynamic factors preceding SCD using continuous telemetry of left ventricular (LV) pressure and the ECG for periods up to 5 mo in swine (n = 37) with hibernating myocardium who experience spontaneous VT/VF in the absence of heart failure or infarction. Hemodynamics and ST deviation at the time of VT/VF were compared with survivors with hibernating myocardium as well as sham controls. All episodes of VT/VF occurred during sympathetic activation and were initiated by single premature ventricular contractions, and the VT degenerated into VF in ∼ 30 s. ECG evidence of ischemia was infrequent and no different from those that survived. Baseline hemodynamics were no different among groups, but LV end-diastolic pressure during sympathetic activation was higher at the time of SCD (37 ± 4 vs. 26 ± 4 mmHg, P < 0.05) and the ECG demonstrated QT shortening (155 ± 4 vs. 173 ± 5 ms, P < 0.05). The week before SCD, both parameters were no different from survivors. These data indicate that there are no differences in the degree of sympathetic activation or hemodynamic stress when VT/VF develops in swine with hibernating myocardium. The transiently elevated LV end-diastolic pressure and QT shortening preceding VT/VF raises the possibility that electrocardiographically silent subendocardial ischemia and/or mechanoelectrical feedback serve as a trigger for the development of SCD in chronic ischemic heart disease.
Determination of Dimensionless Attenuation Coefficient in Shaped Resonators
NASA Technical Reports Server (NTRS)
Daniels, C.; Steinetz, B.; Finkbeiner, J.; Raman, G.; Li, X.
2003-01-01
The value of dimensionless attenuation coefficient is an important factor when numerically predicting high-amplitude acoustic waves in shaped resonators. Both the magnitude of the pressure waveform and the quality factor rely heavily on this dimensionless parameter. Previous authors have stated the values used, but have not completely explained their methods. This work fully describes the methodology used to determine this important parameter. Over a range of frequencies encompassing the fundamental resonance, the pressure waves were experimentally measured at each end of the shaped resonators. At the corresponding dimensionless acceleration, the numerical code modeled the acoustic waveforms generated in the resonator using various dimensionless attenuation coefficients. The dimensionless attenuation coefficient that most closely matched the pressure amplitudes and quality factors of the experimental and numerical results was determined to be the value to be used in subsequent studies.
Evidence for increased cardiac compliance during exposure to simulated microgravity
NASA Technical Reports Server (NTRS)
Koenig, S. C.; Convertino, V. A.; Fanton, J. W.; Reister, C. A.; Gaffney, F. A.; Ludwig, D. A.; Krotov, V. P.; Trambovetsky, E. V.; Latham, R. D.
1998-01-01
We measured hemodynamic responses during 4 days of head-down tilt (HDT) and during graded lower body negative pressure (LBNP) in invasively instrumented rhesus monkeys to test the hypotheses that exposure to simulated microgravity increases cardiac compliance and that decreased stroke volume, cardiac output, and orthostatic tolerance are associated with reduced left ventricular peak dP/dt. Six monkeys underwent two 4-day (96 h) experimental conditions separated by 9 days of ambulatory activities in a crossover counterbalance design: 1) continuous exposure to 10 degrees HDT and 2) approximately 12-14 h per day of 80 degrees head-up tilt and 10-12 h supine (control condition). Each animal underwent measurements of central venous pressure (CVP), left ventricular and aortic pressures, stroke volume, esophageal pressure (EsP), plasma volume, alpha1- and beta1-adrenergic responsiveness, and tolerance to LBNP. HDT induced a hypovolemic and hypoadrenergic state with reduced LBNP tolerance compared with the control condition. Decreased LBNP tolerance with HDT was associated with reduced stroke volume, cardiac output, and peak dP/dt. Compared with the control condition, a 34% reduction in CVP (P = 0.010) and no change in left ventricular end-diastolic area during HDT was associated with increased ventricular compliance (P = 0.0053). Increased cardiac compliance could not be explained by reduced intrathoracic pressure since EsP was unaltered by HDT. Our data provide the first direct evidence that increased cardiac compliance was associated with headward fluid shifts similar to those induced by exposure to spaceflight and that reduced orthostatic tolerance was associated with lower cardiac contractility.
A hemodynamics model to study the collective behavior of the ventricular-arterial system
NASA Astrophysics Data System (ADS)
Lin Wang, Yuh-Ying; Wang, Wei-Kung
2013-01-01
Applying principles from complex systems to study the efficacy of integrative therapies has become a new interest in medical research. We aimed to construct a concise model for the ventricular-arterial (VA) system and to provide a systematic method for exploring its overall behavior. The transportation of blood from the heart to the peripheral arterioles via hydraulic pressure forces was described by a multi-rank model. Parts of the VA system that have strong mutual interactions were combined into a single sub system. Sub systems of four different ranks were characterized. We then applied the multi-rank model to analyze the aortic pressure wave generated by the periodic ventricular blood ejection, the renal pressure in response to the input from the VA system, and the blood flowing from the renal artery to its arterioles. Maintaining the pressure distribution along the main arteries and in all of the organs with the lowest possible ventricular input turned out to be the first principle for the operation of an efficient VA system. By this principle, we pointed out the benefit of some arterial structures in mammals, derived specific regulation rules and deduced some fundamental concepts for healing. The justification of the biomechanics in our model that differed greatly from those in the prevailing models was given. We concluded that the oscillatory motion and the pressure pulse of the arterial system can be analyzed as steady states with resonance behaviors and suggested utilizing this model to construct integrative therapies for diseases correlated with abnormality in blood circulation.
Vender, John; Waller, Jennifer; Dhandapani, Krishnan; McDonnell, Dennis
2011-08-01
Intracranial pressure measurements have become one of the mainstays of traumatic brain injury management. Various technologies exist to monitor intracranial pressure from a variety of locations. Transducers are usually placed to assess pressure in the brain parenchyma and the intra-ventricular fluid, which are the two most widely accepted compartmental monitoring sites. The individual reliability and inter-reliability of these devices with and without cerebrospinal fluid diversion is not clear. The predictive capability of monitors in both of these sites to local, regional, and global changes also needs further clarification. The technique of monitoring intraventricular pressure with a fluid-coupled transducer system is also reviewed. There has been little investigation into the relationship among pressure measurements obtained from these two sources using these three techniques. Eleven consecutive patients with severe, closed traumatic brain injury not requiring intracranial mass lesion evacuation were admitted into this prospective study. Each patient underwent placement of a parenchymal and intraventricular pressure monitor. The ventricular catheter tubing was also connected to a sensor for fluid-coupled measurement. Pressure from all three sources was measured hourly with and without ventricular drainage. Statistically significant correlation within each monitoring site was seen. No monitoring location was more predictive of global pressure changes or more responsive to pressure changes related to patient stimulation. However, the intraventricular pressure measurements were not reliable in the presence of cerebrospinal fluid drainage whereas the parenchymal measurements remained unaffected. Intraparenchymal pressure monitoring provides equivalent, statistically similar pressure measurements when compared to intraventricular monitors in all care and clinical settings. This is particularly valuable when uninterrupted cerebrospinal fluid drainage is desirable.
Magalang, Ulysses J.; Richards, Kathryn; McCarthy, Beth; Fathala, Ahmed; Khan, Meena; Parinandi, Narasimham; Raman, Subha V.
2009-01-01
Study Objectives. There are few data on the effects of continuous positive airway pressure (CPAP) therapy on the structural and functional characteristics of the right heart in patients with obstructive sleep apnea (OSA). We sought to leverage the advantages of cardiac magnetic resonance imaging (CMR) and hypothesized that CPAP treatment would improve right ventricular (RV) function in a group of patients with OSA who were free of other comorbid conditions. Methods. Patients with severe (apnea-hypopnea index ≥ 30/h) untreated OSA were prospectively enrolled. CMR included 3-dimensional measurement of biventricular size and function, and rest/stress myocardial perfusion and was performed at baseline and after 3 months of CPAP therapy. Results. Fifteen patients with mild to moderate desaturation were enrolled; 2 could not undergo CMR due to claustrophobia and obesity. There were significant decreases in the Epworth Sleepiness Scale score (p < 0.0001) and RV end-systolic and RV end-diastolic volumes (p < 0.05) with CPAP. There was a trend toward improvement in RV ejection fraction, but the improvement did not reach statistical significance. Other measures such as left ventricular volumes, left ventricular ejection fraction, myocardial perfusion reserve index, and thickness of the interventricular septum and ventricular free wall did not change significantly. Conclusions: This preliminary study found that CPAP treatment decreases RV volumes in patients with severe OSA who are otherwise healthy. CMR offers a novel technique to determine the effects of CPAP on ventricular structure and function in patients with OSA. A randomized controlled study is needed to confirm the results of our study. Citation: Magalang UJ; Richards K; McCarthy B; Fathala A; Khan M; Parinandi N; Raman SV. Continuous positive airway pressure therapy reduces right ventricular volume in patients with obstructive sleep apnea: a cardiovascular magnetic resonance study. J Clin Sleep Med 2009;5(2):110-114. PMID:19968042
VALSARTAN REGULATES MYOCARDIAL AUTOPHAGY AND MITOCHONDRIAL TURNOVER IN EXPERIMENTAL HYPERTENSION
Zhang, Xin; Li, Zi-Lun; Crane, John A.; Jordan, Kyra L.; Pawar, Aditya S.; Textor, Stephen C.; Lerman, Amir; Lerman, Lilach O.
2014-01-01
Renovascular hypertension alters cardiac structure and function. Autophagy is activated during left ventricular hypertrophy and linked to adverse cardiac function. The Angiotensin II receptor blocker Valsartan lowers blood pressure and is cardioprotective, but whether it modulates autophagy in the myocardium is unclear. We hypothesized that Valsartan would alleviate autophagy and improve left ventricular myocardial mitochondrial turnover in swine renovascular hypertension. Domestic pigs were randomized to control, unilateral renovascular hypertension, and renovascular hypertension treated with Valsartan (320 mg/day) or conventional triple therapy (Reserpine+hydralazine+hydrochlorothiazide) for 4 weeks post 6-weeks of renovascular hypertension (n=7 each group). Left ventricular remodeling, function and myocardial oxygenation and microcirculation were assessed by multi-detector computer tomography, blood-oxygen-level-dependent magnetic resonance imaging and microcomputer tomography. Myocardial autophagy, markers for mitochondrial degradation and biogenesis, and mitochondrial respiratory-chain proteins were examined ex vivo. Renovascular hypertension induced left ventricular hypertrophy and myocardial hypoxia, enhanced cellular autophagy and mitochondrial degradation, and suppressed mitochondrial biogenesis. Valsartan and triple therapy similarly decreased blood pressure, but Valsartan solely alleviated left ventricular hypertrophy, ameliorated myocardial autophagy and mitophagy, and increased mitochondrial biogenesis. In contrast, triple therapy only slightly attenuated autophagy and preserved mitochondrial proteins, but elicited no improvement in mitophagy. These data suggest a novel potential role of Valsartan in modulating myocardial autophagy and mitochondrial turnover in renovascular hypertension-induced hypertensive heart disease, which may possibly bolster cardiac repair via a blood pressure-independent manner. PMID:24752430
Model-Based, Noninvasive Monitoring of Intracranial Pressure
2012-10-01
nICP) estimate requires simultaneous measurement of the waveforms of arterial blood pressure ( ABP ), obtained via radial artery catheter or finger...initial database comprises subarachnoid hemorrhage patients in neuro-intensive care at our partner hospital, for whom ICP, ABP and CBFV are currently
Aldosterone is associated with left ventricular hypertrophy in hemodialysis patients.
Feniman De Stefano, Greicy Mara Mengue; Zanati-Basan, Silméia Garcia; De Stefano, Laercio Martins; Silva, Viviana Rugolo Oliveira E; Xavier, Patrícia Santi; Barretti, Pasqual; da Silva Franco, Roberto Jorge; Caramori, Jacqueline Costa Teixeira; Martin, Luis Cuadrado
2016-10-01
Patients with chronic kidney disease present a higher degree of left ventricular hypertrophy than expected for hypertension levels. In chronic kidney disease the plot between the quotient extracellular water/total body water and aldosterone is shifted up and to the right. There are few studies that verified the role of aldosterone in cardiac remodeling in this set of patients. The aim of this study was to evaluate the relationship between serum aldosterone and left ventricular mass index in patients with chronic kidney disease on hemodialysis. The patients were submitted to clinical and laboratory evaluation, bioelectrical impedance, echocardiography and ambulatory blood pressure monitoring. The 27 patients included were divided into two groups according to aldosterone level and compared with each other. The group of patients with higher aldosterone levels had higher left ventricular mass index. These groups were heterogeneous with regard to ambulatory systolic blood pressure, body mass index, and aldosterone levels and homogeneous with regard to the quotient extracellular water/total body water, renin-angiotensin-aldosterone system blockers, beta blocker use and other clinical characteristics. The association between aldosterone levels and left ventricular mass index was adjusted to confounding variables by a multiple linear regression analysis in which aldosterone was independently associated with left ventricular mass index. The data presented are consistent with a pathogenic role of aldosterone in left ventricular hypertrophy in patients with chronic kidney dialysis in dialysis patients. ClinicalTrials.gov identifier: NCT01128101. © The Author(s), 2016.
Van Herck, P L; Carlier, S G; Claeys, M J; Haine, S E; Gorissen, P; Miljoen, H; Bosmans, J M; Vrints, C J
2007-10-01
To investigate the underlying mechanisms of a decreased coronary flow reserve after myocardial infarction (MI) by analysing the characteristics of the diastolic hyperaemic coronary pressure-flow relationship. Prospective study. Tertiary care hospital. 68 patients with a recent MI and 27 patients with stable angina pectoris (AP; control group). The intercept with the pressure axis (the zero flow pressure or Pzf) and slope index of the pressure-flow relationship (SIPF) were calculated from the simultaneously recorded hyperaemic intracoronary blood flow velocity and aortic pressure after successful coronary stenting. A stepwise increase in Pzf from AP (14.6 (8.0) mm Hg), over non-Q-wave MI (22.5 (9.1) mm Hg), to Q-wave MI (37.1 (12.9) mm Hg; p<0.001) was observed. Similar changes in Pzf were found in a reference artery perfusing the non-infarcted myocardium. Multivariate analysis showed that in both regions the left ventricular end-diastolic pressure (LVEDP) was the most important determinant of the Pzf. The SIPF was not statistically different in the treated vessel between patients with MI and AP, but was increased in MI patients with a markedly increased LVEDP. After an MI, the coronary pressure-flow relationship is shifted to the right both in the infarcted and in the non-infarcted remote myocardium, as shown by the increased Pzf. The correlation with Pzf suggests that elevated left ventricular filling pressures contribute to the impediment of myocardial perfusion in patients with infarction.
Bernheim, Alain M; Kiencke, Stephanie; Fischler, Manuel; Dorschner, Lorenz; Debrunner, Johann; Mairbäurl, Heimo; Maggiorini, Marco; Brunner-La Rocca, Hans Peter
2007-08-01
Altitude-induced pulmonary hypertension has been suggested to cause left ventricular (LV) diastolic dysfunction due to ventricular interaction. In this study, we evaluate the effects of exercise- and altitude-induced increase in pulmonary artery pressures on LV diastolic function in an interventional setting investigating high-altitude pulmonary edema (HAPE) prophylaxis. Among 39 subjects, 29 were HAPE susceptible (HAPE-S) and 10 served as control subjects. HAPE-S subjects were randomly assigned to prophylactic tadalafil (10 mg), dexamethasone (8 mg), or placebo bid, starting 1 day before ascent. Doppler echocardiography at rest and during submaximal exercise was performed at low altitude (490 m) and high altitude (4,559 m). The ratio of early transmitral inflow peak velocity (E) to atrial transmitral inflow peak velocity (A), pulmonary venous flow parameters, and tissue velocity within the septal mitral annulus during early diastole (E') were used to assess LV diastolic properties. LV filling pressures were estimated by E/E'. Systolic right ventricular to atrial pressure gradients (RVPGs) were measured in order to estimate pulmonary artery pressures. At 490 m, E/A decreased similarly with exercise in HAPE-S and control subjects (HAPE-S, 1.5 +/- 0.3 to 1.3 +/- 0.3; control, 1.7 +/- 0.4 to 1.3 +/- 0.3; p = 0.12 between groups) [mean +/- SD], whereas RVPG increased significantly more in HAPE-S subjects (20 +/- 5 to 43 +/- 9 mm Hg vs 18 +/- 3 to 28 +/- 3 mm Hg, p < 0.001). Changes in RVPG levels during exercise did not correlate with changes in E/A (p > 0.1). From 490 to 4,559 m, no correlations between changes in RVPG and changes in E/A or atrial reversal (both p > 0.1) were observed. Neither of the groups showed an increase in E/E' from 490 to 4,559 m. Increased pulmonary artery pressure associated with exercise and acute exposure to 4,559 m appears not to cause LV diastolic dysfunction in healthy subjects. Therefore, ventricular interaction seems not to be of hemodynamic relevance in this setting.
De Lazzari, Claudio; Genuini, Igino; Quatember, Bernhard; Fedele, Francesco
2014-02-01
Patients assisted with left ventricular assist device (LVAD) may require prolonged mechanical ventilatory assistance secondary to postoperative respiratory failure. The goal of this work is the study of the interdependent effects LVAD like pulsatile catheter (PUCA) pump and mechanical ventilatory support or thoracic artificial lung (TAL), by the hemodynamic point of view, using a numerical simulator of the human cardiovascular system. In the simulator, different circulatory sections are described using lumped parameter models. Lumped parameter models have been designed to describe the hydrodynamic behavior of both PUCA pump and thoracic artificial lung. Ventricular behavior atrial and septum functions were reproduced using variable elastance model. Starting from simulated pathological conditions we studied the effects produced on some hemodynamic variables by simultaneous PUCA pump, thoracic artificial lung or mechanical ventilation assistance. Thoracic artificial lung was applied in parallel or in hybrid mode. The effects of mechanical ventilation have been simulated by changing mean intrathoracic pressure value from -4 mmHg to +5 mmHg. The hemodynamic variables observed during the simulations, in different assisted conditions, were: left and right ventricular end systolic (diastolic) volume, systolic/diastolic aortic pressure, mean pulmonary arterial pressure, left and right mean atrial pressure, mean systemic venous pressure and the total blood flow. Results show that the application of PUCA (without mechanical ventilatory assistance) increases the total blood flow, reduces the left ventricular end systolic volume and increases the diastolic aortic pressure. Parallel TAL assistance increases the right ventricular end diastolic (systolic) volume reduction both when PUCA is switched "ON" and both when PUCA is switched "OFF". By switching "OFF" the PUCA pump, it seems that parallel thoracic artificial lung assistance produces a greater cardiac output (respect to hybrid TAL assistance). Results concerning PUCA and TAL interaction produced by simulations cannot be compared with "in vivo" results since they are not presented in literature. But results concerning the effects produced by LVAD and mechanical ventilation have a trend consistent with those presented in literature. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Du, Dongxing; Jiang, Song; Wang, Ze; Hu, Yingying; He, Zhaoming
2014-01-01
Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.
Lim, Ki Moo; Constantino, Jason; Gurev, Viatcheslav; Zhu, Renjun; Trayanova, Natalia A.
2012-01-01
Left ventricular-assist devices (LVADs) are used to supply blood to the body of patients with heart failure. Pressure unloading is greater for counter-pulsating LVADs than for continuous LVADs. However, several clinical trials have demonstrated that myocardial recovery is similar for both types of LVAD. This study examined the contractile energy consumption of the myocardium with continuous and counter-pulsating LVAD support to ascertain the effect of the different LVADs on myocardial recovery. We used a three-dimensional electromechanical model of canine ventricles, with models of the circulatory system and an LVAD. We compared the left ventricular peak pressure (LVPP) and contractile ATP consumption between pulsatile and continuous LVADs. With the continuous and counter-pulsating LVAD, the LVPP decreased to 46 and 10%, respectively, and contractile ATP consumption decreased to 60 and 50%. The small difference between the contractile ATP consumption of these two types of LVAD may explain the comparable effects of the two types on myocardial recovery. PMID:22076841
Alashi, Alaa; Mentias, Amgad; Patel, Krishna; Gillinov, A Marc; Sabik, Joseph F; Popović, Zoran B; Mihaljevic, Tomislav; Suri, Rakesh M; Rodriguez, L Leonardo; Svensson, Lars G; Griffin, Brian P; Desai, Milind Y
2016-07-01
In asymptomatic patients with ≥3+ mitral regurgitation and preserved left ventricular (LV) ejection fraction who underwent mitral valve surgery, we sought to discover whether baseline LV global longitudinal strain (LV-GLS) and brain natriuretic peptide provided incremental prognostic utility. Four hundred and forty-eight asymptomatic patients (61±12 years and 69% men) with ≥3+ primary mitral regurgitation and preserved left ventricular ejection fraction, who underwent mitral valve surgery (92% repair) at our center between 2005 and 2008, were studied. Baseline clinical and echocardiographic data (including LV-GLS using Velocity Vector Imaging, Siemens, PA) were recorded. The Society of Thoracic Surgeons score was calculated. The primary outcome was death. Mean Society of Thoracic Surgeons score, left ventricular ejection fraction, mitral effective regurgitant orifice, indexed LV end-diastolic volume, and right ventricular systolic pressure were 4±1%, 62±3%, 0.55±0.2 cm(2), 58±13 cc/m(2), and 37±15 mm Hg, respectively. Forty-five percent of patients had flail. Median log-transformed BNP and LV-GLS were 4.04 (absolute brain natriuretic peptide: 60 pg/dL) and -20.7%. At 7.7±2 years, death occurred in 41 patients (9%; 0% at 30 days). On Cox analysis, a higher Society of Thoracic Surgeons score (hazard ratio 1.55), higher baseline right ventricular systolic pressure (hazard ratio 1.11), more abnormal LV-GLS (hazard ratio 1.17), and higher median log-transformed BNP (hazard ratio 2.26) were associated with worse longer-term survival (all P<0.01). Addition of LV-GLS and median log-transformed BNP to a clinical model (Society of Thoracic Surgeons score and baseline right ventricular systolic pressure) provided incremental prognostic utility (χ(2) for longer-term mortality increased from 31-47 to 61; P<0.001). In asymptomatic patients with significant primary mitral regurgitation and preserved left ventricular ejection fraction who underwent mitral valve surgery, brain natriuretic peptide and LV-GLS provided synergistic risk stratification, independent of established factors. © 2016 American Heart Association, Inc.
Han, June-Chiew; Guild, Sarah-Jane; Pham, Toan; Nisbet, Linley; Tran, Kenneth; Taberner, Andrew J.; Loiselle, Denis S.
2018-01-01
Pulmonary arterial hypertension (PAH) alters the geometries of both ventricles of the heart. While the right ventricle (RV) hypertrophies, the left ventricle (LV) atrophies. Multiple lines of clinical and experimental evidence lead us to hypothesize that the impaired stroke volume and systolic pressure of the LV are a direct consequence of the effect of pressure overload in the RV, and that atrophy in the LV plays only a minor role. In this study, we tested this hypothesis by examining the mechanoenergetic response of the atrophied LV to RV hypertrophy in rats treated with monocrotaline. Experiments were performed across multiple-scales: the whole-heart in vivo and ex vivo, and its trabeculae in vitro. Under the in vivo state where the RV was pressure-overloaded, we measured reduced systemic blood pressure and LV ventricular pressure. In contrast, under both ex vivo and in vitro conditions, where the effect of RV pressure overload was circumvented, we found that LV was capable of developing normal systolic pressure and stress. Nevertheless, LV atrophy played a minor role in that LV stroke volume remained lower, thereby contributing to lower LV mechanical work output. Concomitantly lower oxygen consumption and change of enthalpy were observed, and hence LV energy efficiency was unchanged. Our internally consistent findings between working-heart and trabecula experiments explain the rapid improvement of LV systolic function observed in patients with chronic pulmonary hypertension following surgical relief of RV pressure overload. PMID:29375394
Picosecond High Pressure Gas Switch Experiment
1993-06-01
the calculated pulse waveform for a much higher voltage and pressure switch . Also, a discussion of the modifications made on an existing pulse...s 80 8 ~ 60 J 40 .. : ~--~: __ ~’----~-~ 0.1 10 100 1000 Frequency Figure 7. Output switch recovery. Conclusion The high- pressure switch has...effective in matching experimental results, and should thus be useful in the design of high-voltage and pressure switch configurations
Right ventricular involvement in cardiac sarcoidosis demonstrated with cardiac magnetic resonance
van Geuns, Robert‐Jan; Ainslie, Gillian; Ector, Joris; Heidbuchel, Hein; Crijns, Harry J.G.M.
2017-01-01
Abstract Aims Cardiac involvement in sarcoidosis is reported in up to 30% of patients. Left ventricular involvement demonstrated by contrast‐enhanced cardiac magnetic resonance has been well validated. We sought to determine the prevalence and distribution of right ventricular late gadolinium enhancement in patients diagnosed with pulmonary sarcoidosis. Methods and results We prospectively evaluated 87 patients diagnosed with pulmonary sarcoidosis with contrast‐enhanced cardiac magnetic resonance for right ventricular involvement. Pulmonary artery pressures were non‐invasively evaluated with Doppler echocardiography. Patient characteristics were compared between the groups with and without right ventricular involvement, and right ventricular enhancement was correlated with pulmonary hypertension, ventricular mass, volume, and systolic function. Left ventricular late gadolinium enhancement was demonstrated in 30 patients (34%). Fourteen patients (16%) had right ventricular late gadolinium enhancement, with sole right ventricular enhancement in only two patients. The pattern of right ventricular enhancement consisted of right ventricular outflow tract enhancement in 1 patient, free wall enhancement in 8 patients, ventricular insertion point enhancement in 10 patients, and enhancement of the right side of the interventricular septum in 11 patients. Pulmonary arterial hypertension correlated with the presence of right ventricular enhancement (P < 0.001). Right ventricular enhancement correlated with systolic ventricular dysfunction (P < 0.001), hypertrophy (P = 0.001), and dilation (P < 0.001). Conclusions Right ventricular enhancement was present in 16% of patients diagnosed with pulmonary sarcoidosis and in 48% of patients with left ventricular enhancement. The presence of right ventricular enhancement correlated with pulmonary arterial hypertension, right ventricular systolic dysfunction, hypertrophy, and dilation. PMID:29154434
Comparison of sarcolemmal calcium channel current in rabbit and rat ventricular myocytes.
Yuan, W; Ginsburg, K S; Bers, D M
1996-01-01
1. Fundamental properties of Ca2+ channel currents in rat and rabbit ventricular myocytes were measured using whole cell voltage clamp. 2. In rat, as compared with rabbit myocytes, Ca2+ channel current (ICa) was half-activated at about 10 mV more negative potential, decayed slower, was half-inactivated (in steady state) at about 5 mV more positive potential, and recovered faster from inactivation. 3. These features result in a larger steady-state window current in rat, and also suggest that under comparable voltage clamp conditions, including action potential (AP) clamp, more Ca2+ influx would be expected in rat myocytes. 4. Ca2+ channel current carried by Na+ and Cs+ in the absence of divalent ions (Ins) also activated at more negative potential and decayed more slowly in rat. 5. The reversal potential for Ins was 6 mV more positive in rabbit, consistent with a larger permeability ratio (PNa/PCs) in rabbit than in rat. ICa also reversed at slightly more positive potentials in rabbit (such that PCa/PCs might also be higher). 6. Ca2+ influx was calculated by integration of ICa evoked by voltage clamp pulses (either square pulses or pulses based on recorded rabbit or rat APs). For a given clamp waveform, the Ca2+ influx was up to 25% greater in rat, as predicted from the fundamental properties of ICa and Ins. 7. However, the longer duration of the AP in rabbit myocytes compensated for the difference in influx, such that the integrated Ca2+ influx via ICa in response to the species-appropriate waveform was about twice as large as that seen in rat. PMID:8799895
Gao, Mingwu; Cheng, Hao-Min; Sung, Shih-Hsien; Chen, Chen-Huan; Olivier, Nicholas Bari; Mukkamala, Ramakrishna
2017-07-01
pulse transit time (PTT) varies with blood pressure (BP) throughout the cardiac cycle, yet, because of wave reflection, only one PTT value at the diastolic BP level is conventionally estimated from proximal and distal BP waveforms. The objective was to establish a technique to estimate multiple PTT values at different BP levels in the cardiac cycle. a technique was developed for estimating PTT as a function of BP (to indicate the PTT value for every BP level) from proximal and distal BP waveforms. First, a mathematical transformation from one waveform to the other is defined in terms of the parameters of a nonlinear arterial tube-load model accounting for BP-dependent arterial compliance and wave reflection. Then, the parameters are estimated by optimally fitting the waveforms to each other via the model-based transformation. Finally, PTT as a function of BP is specified by the parameters. The technique was assessed in animals and patients in several ways including the ability of its estimated PTT-BP function to serve as a subject-specific curve for calibrating PTT to BP. the calibration curve derived by the technique during a baseline period yielded bias and precision errors in mean BP of 5.1 ± 0.9 and 6.6 ± 1.0 mmHg, respectively, during hemodynamic interventions that varied mean BP widely. the new technique may permit, for the first time, estimation of PTT values throughout the cardiac cycle from proximal and distal waveforms. the technique could potentially be applied to improve arterial stiffness monitoring and help realize cuff-less BP monitoring.
Comparison of acoustic fields produced by the original and upgraded HM-3 lithotripter
NASA Astrophysics Data System (ADS)
Zhou, Yufeng; Zhu, Songlin; Dreyer, Thomas; Liebler, Marko; Zhong, Pei
2003-10-01
To reduce tissue injury in shock wave lithotripsy (SWL) while maintaining satisfactory stone comminution, an original HM-3 lithotripter was upgraded by a reflector insert to suppress large intraluminal bubble expansion, which is a primary mechanism of vascular injury in SWL. The pressure waveforms produced by the original and upgraded HM-3 lithotripter were measured by using a fiber optical probe hydrophone (FOPH), which was scanned both along and transverse to the lithotripter axis at 1-mm step using a computer-controlled 3-D positioning system. At F2, the pressure waveform produced by the upgraded HM-3 lithotripter at 22 kV has a distinct dual-pulse structure, with a leading shock wave of ~45 MPa from the reflector insert and a 4-μs delayed second pulse of ~15 MPa reflected from the uncovered bottom surface of the original HM-3 reflector. The beam sizes of the original and upgraded HM-3 lithotripter are comparable in both axial and lateral directions. The pressure waveforms measured at the reflector aperture will be used as input to the KZK equation to predict the lithotripter shock wave at F2. Furthermore, bubble dynamics predicted by the Gilmore model will be compared with experimental observation by high-speed imaging. [Work supported by NIH.
Kim, Nick H S; Fesler, Pierre; Channick, Richard N; Knowlton, Kirk U; Ben-Yehuda, Ori; Lee, Stephen H; Naeije, Robert; Rubin, Lewis J
2004-01-06
Pulmonary thromboendarterectomy (PTE) is the preferred treatment for chronic thromboembolic pulmonary hypertension (CTEPH), but persistent pulmonary hypertension after PTE, as a result of either inaccessible distal thrombotic material or coexistent intrinsic small-vessel disease, remains a major determinant of poor outcome. Conventional preoperative evaluation is unreliable in identifying patients at risk for persistent pulmonary hypertension or predicting postoperative hemodynamic outcome. We postulated that pulmonary arterial occlusion pressure waveform analysis, a technique that has been used for partitioning pulmonary vascular resistance, might identify CTEPH patients with significant distal, small-vessel disease. Twenty-six patients underwent preoperative right heart catheterization before PTE. Pulmonary artery occlusion waveform recordings were performed in triplicate. Postoperative hemodynamics after PTE were compared with preoperative partitioning of pulmonary vascular resistance derived from the occlusion data. Preoperative assessment of upstream resistance (Rup) correlated with both postoperative total pulmonary resistance index (R2=0.79, P<0.001) and postoperative mean pulmonary artery pressure (R2=0.75, P<0.001). All 4 postoperative deaths occurred in patients with a preoperative Rup <60%. Pulmonary arterial occlusion pressure waveform analysis may identify CTEPH patients at risk for persistent pulmonary hypertension and poor outcome after PTE. Patients with CTEPH and Rup value <60% appear to be at highest risk.
Liu, Chengyu; Zheng, Dingchang; Zhao, Lina; Liu, Changchun
2014-01-01
It has been reported that Gaussian functions could accurately and reliably model both carotid and radial artery pressure waveforms (CAPW and RAPW). However, the physiological relevance of the characteristic features from the modeled Gaussian functions has been little investigated. This study thus aimed to determine characteristic features from the Gaussian functions and to make comparisons of them between normal subjects and heart failure patients. Fifty-six normal subjects and 51 patients with heart failure were studied with the CAPW and RAPW signals recorded simultaneously. The two signals were normalized first and then modeled by three positive Gaussian functions, with their peak amplitude, peak time, and half-width determined. Comparisons of these features were finally made between the two groups. Results indicated that the peak amplitude of the first Gaussian curve was significantly decreased in heart failure patients compared with normal subjects (P<0.001). Significantly increased peak amplitude of the second Gaussian curves (P<0.001) and significantly shortened peak times of the second and third Gaussian curves (both P<0.001) were also presented in heart failure patients. These results were true for both CAPW and RAPW signals, indicating the clinical significance of the Gaussian modeling, which should provide essential tools for further understanding the underlying physiological mechanisms of the artery pressure waveform.
Adverse Heart-Lung Interactions in Ventilator-induced Lung Injury.
Katira, Bhushan H; Giesinger, Regan E; Engelberts, Doreen; Zabini, Diana; Kornecki, Alik; Otulakowski, Gail; Yoshida, Takeshi; Kuebler, Wolfgang M; McNamara, Patrick J; Connelly, Kim A; Kavanagh, Brian P
2017-12-01
In the original 1974 in vivo study of ventilator-induced lung injury, Webb and Tierney reported that high Vt with zero positive end-expiratory pressure caused overwhelming lung injury, subsequently shown by others to be due to lung shear stress. To reproduce the lung injury and edema examined in the Webb and Tierney study and to investigate the underlying mechanism thereof. Sprague-Dawley rats weighing approximately 400 g received mechanical ventilation for 60 minutes according to the protocol of Webb and Tierney (airway pressures of 14/0, 30/0, 45/10, 45/0 cm H 2 O). Additional series of experiments (20 min in duration to ensure all animals survived) were studied to assess permeability (n = 4 per group), echocardiography (n = 4 per group), and right and left ventricular pressure (n = 5 and n = 4 per group, respectively). The original Webb and Tierney results were replicated in terms of lung/body weight ratio (45/0 > 45/10 ≈ 30/0 ≈ 14/0; P < 0.05) and histology. In 45/0, pulmonary edema was overt and rapid, with survival less than 30 minutes. In 45/0 (but not 45/10), there was an increase in microvascular permeability, cyclical abolition of preload, and progressive dilation of the right ventricle. Although left ventricular end-diastolic pressure decreased in 45/10, it increased in 45/0. In a classic model of ventilator-induced lung injury, high peak pressure (and zero positive end-expiratory pressure) causes respiratory swings (obliteration during inspiration) in right ventricular filling and pulmonary perfusion, ultimately resulting in right ventricular failure and dilation. Pulmonary edema was due to increased permeability, which was augmented by a modest (approximately 40%) increase in hydrostatic pressure. The lung injury and acute cor pulmonale is likely due to pulmonary microvascular injury, the mechanism of which is uncertain, but which may be due to cyclic interruption and exaggeration of pulmonary blood flow.
Bello, Hamza; Norton, Gavin R; Ballim, Imraan; Libhaber, Carlos D; Sareli, Pinhas; Woodiwiss, Angela J
2017-05-01
Aortic pulse wave velocity (PWV) and backward waves, as determined from wave separation analysis, predict cardiovascular events beyond brachial blood pressure. However, the extent to which these aortic hemodynamic variables contribute independent of each other is uncertain. In 749 randomly selected participants of African ancestry, we therefore assessed the extent to which relationships between aortic PWV or backward wave pressures (Pb) (and hence central aortic pulse pressure [PPc]) and left ventricular mass index (LVMI) occur independent of each other. Aortic PWV, PPc, forward wave pressure (Pf), and Pb were determined using radial applanation tonometry and SphygmoCor software and LVMI using echocardiography; 44.5% of participants had an increased left ventricular mass indexed to height 1.7 . With adjustments for age, brachial systolic blood pressure or PP, and additional confounders, PPc and Pb, but not Pf, were independently related to LVMI and left ventricular hypertrophy (LVH) in both men and women. However, PWV was independently associated with LVMI in women (partial r = 0.16, P < .001), but not in men (partial r = 0.03), and PWV was independently associated with LVH in women (P < .05), but not in men (P = .07). With PWV and Pb included in the same multivariate regression models, PWV (partial r = 0.14, P < .005) and Pb (partial r = 0.10, P < .05) contributed to a similar extent to variations in LVMI in women. In addition, with PWV and Pb included in the same multivariate regression models, PWV (P < .05) and Pb (P < .02) contributed to LVH in women. In conclusion, aortic PWV and Pb (and hence pulse pressure) although both associated with LVMI and LVH produce effects which are independent of each other. Copyright © 2017 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
A Waveform Archiving System for the GE Solar 8000i Bedside Monitor.
Fanelli, Andrea; Jaishankar, Rohan; Filippidis, Aristotelis; Holsapple, James; Heldt, Thomas
2018-01-01
Our objective was to develop, deploy, and test a data-acquisition system for the reliable and robust archiving of high-resolution physiological waveform data from a variety of bedside monitoring devices, including the GE Solar 8000i patient monitor, and for the logging of ancillary clinical and demographic information. The data-acquisition system consists of a computer-based archiving unit and a GE Tram Rac 4A that connects to the GE Solar 8000i monitor. Standard physiological front-end sensors connect directly to the Tram Rac, which serves as a port replicator for the GE monitor and provides access to these waveform signals through an analog data interface. Together with the GE monitoring data streams, we simultaneously collect the cerebral blood flow velocity envelope from a transcranial Doppler ultrasound system and a non-invasive arterial blood pressure waveform along a common time axis. All waveform signals are digitized and archived through a LabView-controlled interface that also allows for the logging of relevant meta-data such as clinical and patient demographic information. The acquisition system was certified for hospital use by the clinical engineering team at Boston Medical Center, Boston, MA, USA. Over a 12-month period, we collected 57 datasets from 11 neuro-ICU patients. The system provided reliable and failure-free waveform archiving. We measured an average temporal drift between waveforms from different monitoring devices of 1 ms every 66 min of recorded data. The waveform acquisition system allows for robust real-time data acquisition, processing, and archiving of waveforms. The temporal drift between waveforms archived from different devices is entirely negligible, even for long-term recording.
Honda, Yoshihiro; Suzuki, Shoji; Kaga, Shigeaki; Yoshida, Yukiyo; Kimura, Mitsuhiro; Kamiya, Kentaro; Sakakibara, Kenji; Katsu, Masatake
2015-05-01
The patient was diagnosed with tetralogy of Fallot associated with absent pulmonary valve syndrome and a low birth weight of 1,912 g. He suffered from respiratory distress on day 14 and received non-invasive positive pressure ventilation. At 5 months of age and 4.1 kg, he underwent intracardiac repair including right ventricular outflow repair with a monocusp patch, patch closure of the ventricular septum defect and right pulmonary transposition to the anterior of the ascending aorta following the Lecompte maneuver for airway decompression. He was subsequently discharged to home and exhibited an uneventful clinical course with non-invasive positive pressure ventilation for 5 months postoperatively. However, right pulmonary artery and supra-aortic stenosis was noted 2 years after the operation. Computed tomography (CT) and angiography showed ascending aorta strangulation by the right pulmonary artery with right ventricular outflow regurgitation. Right pulmonary artery reconstruction using polytetrafluoroethylene graft interposition and repeat right ventricular outflow repair with bicuspid hand-sewn valves was therefore performed;the postoperative course was uneventful. Pre- and post-operative management using non-invasive positive pressure ventilation and airway decompression with pulmonary artery translocation is a useful strategy in patients exhibiting symptomatic tetralogy of Fallot associated with absent pulmonary valve syndrome in the neonatal period.
Huang, Jui-Tzu; Cheng, Hao-Min; Yu, Wen-Chung; Lin, Yao-Ping; Sung, Shih-Hsien; Wang, Jiun-Jr; Wu, Chung-Li; Chen, Chen-Huan
2017-11-29
The excess pressure integral (XSPI), derived from analysis of the arterial pressure curve, may be a significant predictor of cardiovascular events in high-risk patients. We comprehensively investigated the prognostic value of XSPI for predicting long-term mortality in end-stage renal disease patients undergoing regular hemodialysis. A total of 267 uremic patients (50.2% female; mean age 54.2±14.9 years) receiving regular hemodialysis for more than 6 months were enrolled. Cardiovascular parameters were obtained by echocardiography and applanation tonometry. Calibrated carotid arterial pressure waveforms were analyzed according to the wave-transmission and reservoir-wave theories. Multivariable Cox proportional hazard models were constructed to account for age, sex, diabetes mellitus, albumin, body mass index, and hemodialysis treatment adequacy. Incremental utility of the parameters to risk stratification was assessed by net reclassification improvement. During a median follow-up of 15.3 years, 124 deaths (46.4%) incurred. Baseline XSPI was significantly predictive of all-cause (hazard ratio per 1 SD 1.4, 95% confidence interval 1.15-1.70, P =0.0006) and cardiovascular mortalities (1.47, 1.18-1.84, P =0.0006) after accounting for the covariates. The addition of XSPI to the base prognostic model significantly improved prediction of both all-cause mortality (net reclassification improvement=0.1549, P =0.0012) and cardiovascular mortality (net reclassification improvement=0.1535, P =0.0033). XSPI was superior to carotid-pulse wave velocity, forward and backward wave amplitudes, and left ventricular ejection fraction in consideration of overall independent and incremental prognostics values. In end-stage renal disease patients undergoing regular hemodialysis, XSPI was significantly predictive of long-term mortality and demonstrated an incremental value to conventional prognostic factors. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Effect of atrial systole on canine and porcine coronary blood flow.
Bellamy, R F
1981-09-01
A feature of phasic coronary flow patterns recorded in conscious chronically instrumented dogs is the atrial cove--a transient depression of arterial flow that occurs during atrial systole. The association between the hemodynamic effects of atrial systole and the atrial cove was studied in anesthetized dogs and pigs with complete heart block. Many atrial coves are available for study in these preparations because atrial activity continues unabated during the diastolic ventricular arrest that follows cessation of electrical pacing. The effect of atrial systole is to translate the pressure-flow relation found during diastole to a higher intercept pressure without change in slope. The increase in the intercept pressure equals the increase in intramyocardial pressure measured with microtransducers embedded in the left ventricular wall. The decrement in flow during the atrial cove is a direct function of the change in intramyocardial pressure and an inverse function of coronary vascular resistance. Each atrial systole is associated with a forward flow transient in the coronary veins, the peak of which occurs at the same instant as does the nadir of atrial flow. These data suggest that the coronary vessels are acting as collapsible tubes and that the waterfall model of the coronary circulation is applicable. The following sequence is proposed to account for the atrial cove. Atrial systole ejects a bolus of blood into the left ventricle increasing both ventricular cavity and intramyocardial pressures. The increase in intramyocardial pressure raises the back pressure opposing coronary flow, reducing the arterial perfusion pressure gradient and causing flow to fall.
Al-Nashi, Maha; Eriksson, Maria J; Östlund, Eva; Bremme, Katarina; Kahan, Thomas
2016-04-01
Preeclampsia (PE) is associated with acute left ventricular dysfunction. Whether these changes eventually resolve remains unclear. This study assessed left and right ventricular structure and function, and ventricular-arterial interaction in 15 women 11 years after a pregnancy with PE and 16 matched control subjects with a normal pregnancy. We found normal left and right ventricular dimensions, systolic function, and global left ventricular strain, with no differences between the groups. In addition, indices of diastolic function, left and right atrial size, and amino-terminal pro-brain natriuretic peptide were normal and did not differ between the groups. Women with a previous PE had impaired night/day ratios for systolic and diastolic ambulatory blood pressure. However, indices of aortic stiffness or ventricular-arterial coupling did not differ between the groups. In conclusion, we could not demonstrate remaining alterations in systolic or diastolic left or right ventricular function, or in ventricular-arterial interaction in women 11 years after PE. Copyright © 2016 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
El-Said, Howaida; Hegde, Sanjeet; Moore, John
2014-01-01
The patient was a male infant with L-transposition of great arteries (L-TGA), Ebstein's anomaly of the tricuspid valve, subvalvar aortic stenosis, ventricular septal defect (VSD), hypoplastic right ventricle, arch hypoplasia, and congenital complete heart block. He underwent a Norwood procedure, aortic arch repair, permanent pacemaker implantation, and a 3.5-mm aortopulmonary shunt at 4 days of age. At the time of his surgery, left ventricular function was in the normal range (ejection fraction [EF] = 67%). However by 3 months of age, he was noted to have developed moderate-severe biventricular dysfunction (left ventricular ejection fraction [LVEF] = 34%). Atresia of the coronary sinus with a small left superior venacava (LSVC) and a bridging vein was discovered during cardiac catheterization at this time. The coronary sinus mean pressure was 17 mm Hg, and the common atrial mean pressure was 6 mmHg. We opened the atretic coronary sinus ostium using radiofrequency ablation and stent placement. There was dramatic improvement in ventricular function observed over a 2-month period. Follow-up cardiac catheterization 5 months later revealed the stent in the coronary sinus to be widely patent with no intimal buildup, and the ventricular function was normal (LVEF = 58%). The patient had a bidirectional Glenn procedure with an uncomplicated postoperative course and is currently awaiting Fontan completion. © 2013 Wiley Periodicals, Inc.
Liu, Yunbo; Wear, Keith A.; Harris, Gerald R.
2017-01-01
Reliable acoustic characterization is fundamental for patient safety and clinical efficacy during high intensity therapeutic ultrasound (HITU) treatment. Technical challenges, such as measurement uncertainty and signal analysis still exist for HITU exposimetry using ultrasound hydrophones. In this work, four hydrophones were compared for pressure measurement: a robust needle hydrophone, a small PVDF capsule hydrophone and two different fiber-optic hydrophones. The focal waveform and beam distribution of a single element HITU transducer (1.05 MHz and 3.3 MHz) were evaluated. Complex deconvolution between the hydrophone voltage signal and frequency-dependent complex sensitivity was performed to obtain pressure waveform. Compressional pressure, rarefactional pressure, and focal beam distribution were compared up to 10.6/−6.0 MPa (p+ and p−) (1.05 MHz) and 20.65/−7.20 MPa (3.3 MHz). In particular, the effects of spatial averaging, local nonlinear distortion, complex deconvolution and hydrophone damage thresholds were investigated. This study showed an uncertainty of no better than 10–15% on hydrophone-based HITU pressure characterization. PMID:28735734
Pueschner, Andreas; Chattranukulchai, Pairoj; Heitner, John F; Shah, Dipan J; Hayes, Brenda; Rehwald, Wolfgang; Parker, Michele A; Kim, Han W; Judd, Robert M; Kim, Raymond J; Klem, Igor
2017-10-01
This study sought to determine the prevalence, correlates, and impact on cardiac mortality of right ventricular (RV) dysfunction in nonischemic cardiomyopathy. Current heart failure guidelines place little emphasis on RV assessment due to limited available data on determinants of RV function, mechanisms leading to its failure, and relation to outcomes. We prospectively studied 423 patients with cardiac magnetic resonance (CMR). The pre-specified study endpoint was cardiac mortality. In 100 patients, right heart catheterization was performed as clinically indicated. During a median follow-up time of 6.2 years (interquartile range: 2.9 to 7.6 years), 101 patients (24%) died of cardiac causes. CMR right ventricular ejection fraction (RVEF) was a strong independent predictor of cardiac mortality after adjustment for age, heart failure-functional class, blood pressure, heart rate, serum sodium, serum creatinine, myocardial scar, and left ventricular ejection fraction (LVEF). Patients with the lowest quintile of RVEF had a nearly 5-fold higher cardiac mortality risk than did patients with the highest quintile (hazard ratio: 4.68; 95% confidence interval [CI]: 2.43 to 9.02; p < 0.0001). RVEF was positively correlated with LVEF (r = 0.60; p < 0.0001), and inversely correlated with right atrial pressure (r = -0.32; p = 0.001), pulmonary artery pressure (r = -0.34; p = 0.0005), transpulmonary gradient (r = -0.28; p = 0.006) but not with pulmonary wedge pressure (r = -0.15; p = 0.13). In multivariable logistic regression analysis of CMR, clinical, and hemodynamic data the strongest predictors of right ventricular dysfunction were LVEF (odds ratio [OR]: 0.85; 95% CI: 0.78 to 0.92; p < 0.0001), transpulmonary gradient (OR: 1.20; 95% CI: 1.09 to 1.32; p = 0.0003), and systolic blood pressure (OR: 0.97; 95% CI: 0.94 to 0.99; p = 0.02). CMR assessment of RVEF provides important prognostic information independent of established risk factors and LVEF in heart failure patients with nonischemic cardiomyopathy. Right ventricular dysfunction is strongly associated with both indices of intrinsic myocardial contractility and increased afterload from pulmonary vascular dysfunction. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Zhou, Hourong; Huang, Jia; Zhu, Li; Cao, Yu
2018-01-01
Activation of renin-angiotensin system (RAS) is one of the pathological mechanisms associated with myocardial ischemia-reperfusion injury following resuscitation. The present study aimed to determine whether erythropoietin (EPO) improves post-resuscitation myocardial dysfunction and how it affects the renin-angiotensin system. Sprague-Dawley rats were randomly divided into sham, vehicle, epinephrine (EP), EPO and EP + EPO groups. Excluding the sham group, all groups underwent cardiopulmonary resuscitation (CPR) 4 min after asphyxia-induced cardiac arrest (CA). EP and/or EPO was administrated by intravenous injection when CPR began. The results demonstrated that the vehicle group exhibited lower mean arterial pressure, left ventricular systolic pressure, maximal ascending rate of left ventricular pressure during left ventricular isovolumic contraction and maximal descending rate of left ventricular pressure during left ventricular isovolumic relaxation (+LVdP/dt max and -LVdP/dt max, respectively), and higher left ventricular end-diastolic pressure, compared with the sham group following return of spontaneous circulation (ROSC). Few significant differences were observed concerning the myocardial function between the vehicle and EP groups; however, compared with the vehicle group, EPO reversed myocardial function indices following ROSC, excluding-LVdP/dt max. Serum renin and angiotensin (Ang) II levels were measured by ELISA. The serum levels of renin and Ang II were significantly increased in the vehicle group compared with the sham group, which was also observed for the myocardial expression of renin and Ang II receptor type 1 (AT1R), as determined by reverse transcription-quantitative polymerase chain reaction and western blotting. EPO alone did not significantly reduce the high serum levels of renin and Ang II post-resuscitation, but changed the protein levels of renin and AT1R expression in myocardial tissues. However, EPO enhanced the myocardial expression of Ang II receptor type 2 (AT2R) following ROSC. In conclusion, the present study confirmed that CA resuscitation activated the renin-Ang II-AT1R signaling pathway, which may contribute to myocardial dysfunction in rats. The present study confirmed that EPO treatment is beneficial for protecting cardiac function post-resuscitation, and the roles of EPO in alleviating post-resuscitation myocardial dysfunction may potentially be associated with enhanced myocardial expression of AT2R. PMID:29393490
Reliability of Waveform Analysis as an Adjunct to Loss of Resistance for Thoracic Epidural Blocks.
Leurcharusmee, Prangmalee; Arnuntasupakul, Vanlapa; Chora De La Garza, Daniel; Vijitpavan, Amorn; Ah-Kye, Sonia; Saelao, Abhidej; Tiyaprasertkul, Worakamol; Finlayson, Roderick J; Tran, De Q H
2015-01-01
The epidural space is most commonly identified with loss of resistance (LOR). Although sensitive, LOR lacks specificity, as cysts in interspinous ligaments, gaps in ligamentum flavum, paravertebral muscles, thoracic paravertebral spaces, and intermuscular planes can yield nonepidural LOR. Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for LOR. When the needle is correctly positioned inside the epidural space, measurement of the pressure at its tip results in a pulsatile waveform. In this observational study, we set out to assess the sensitivity, specificity, as well as positive and negative predictive values of EWA for thoracic epidural blocks. We enrolled a convenience sample of 160 patients undergoing thoracic epidural blocks for thoracic surgery, abdominal surgery, or rib fractures. The choice of patient position (sitting or lateral decubitus), approach (midline or paramedian), and LOR medium (air or normal saline) was left to the operator (attending anesthesiologist, fellow, or resident). After obtaining a satisfactory LOR, the operator injected 5 mL of normal saline through the epidural needle. A sterile tubing, connected to a pressure transducer, was attached to the needle to measure the pressure at the needle tip. A 4-mL bolus of lidocaine 2% with epinephrine 5 μg/mL was then administered and, after 10 minutes, the patient was assessed for sensory blockade to ice. The failure rate (incorrect identification of the epidural space with LOR) was 23.1%. Of these 37 failed epidural blocks, 27 provided no sensory anesthesia at 10 minutes. In 10 subjects, the operator was unable to thread the catheter through the needle. When compared with the ice test, the sensitivity, specificity, and positive and negative predictive values of EWA were 91.1%, 83.8%, 94.9%, and 73.8%, respectively. Epidural waveform analysis (with pressure transduction through the needle) provides a simple adjunct to LOR for thoracic epidural blocks. Although its use was devoid of complications, further confirmatory studies are required before its routine implementation in clinical practice.
Ghanta, Ravi K; Rangaraj, Aravind; Umakanthan, Ramanan; Lee, Lawrence; Laurence, Rita G; Fox, John A; Bolman, R Morton; Cohn, Lawrence H; Chen, Frederick Y
2007-03-13
Ventricular restraint is a nontransplantation surgical treatment for heart failure. The effect of varying restraint level on left ventricular (LV) mechanics and remodeling is not known. We hypothesized that restraint level may affect therapy efficacy. We studied the immediate effect of varying restraint levels in an ovine heart failure model. We then studied the long-term effect of restraint applied over a 2-month period. Restraint level was quantified by use of fluid-filled epicardial balloons placed around the ventricles and measurement of balloon luminal pressure at end diastole. At 4 different restraint levels (0, 3, 5, and 8 mm Hg), transmural myocardial pressure (P(tm)) and indices of myocardial oxygen consumption (MVO2) were determined in control (n=5) and ovine heart failure (n=5). Ventricular restraint therapy decreased P(tm) and MVO2, and improved mechanical efficiency. An optimal physiological restraint level of 3 mm Hg was identified to maximize improvement without an adverse affect on systemic hemodynamics. At this optimal level, end-diastolic P(tm) and MVO2 indices decreased by 27% and 20%, respectively. The serial longitudinal effects of optimized ventricular restraint were then evaluated in ovine heart failure with (n=3) and without (n=3) restraint over 2 months. Optimized ventricular restraint prevented and reversed pathological LV dilatation (130+/-22 mL to 91+/-18 mL) and improved LV ejection fraction (27+/-3% to 43+/-5%). Measured restraint level decreased over time as the LV became smaller, and reverse remodeling slowed. Ventricular restraint level affects the degree of decrease in P(tm), the degree of decrease in MVO2, and the rate of LV reverse remodeling. Periodic physiological adjustments of restraint level may be required for optimal restraint therapy efficacy.
Inoue, Tomoaki; Sonoda, Noriyuki; Hiramatsu, Shinsuke; Kimura, Shinichiro; Ogawa, Yoshihiro; Inoguchi, Toyoshi
2018-02-01
Previous studies have shown that serum bilirubin concentration is inversely associated with the risk of cardiovascular disease. The relationship between serum bilirubin concentration and left ventricular geometry, however, has not been investigated in patients with diabetes mellitus. In this cohort study, 158 asymptomatic patients with type 2 diabetes mellitus without overt heart disease were enrolled. Left ventricular structure and function were assessed using echocardiography. Serum bilirubin concentration, glycemic control, lipid profile, and other clinical characteristics were evaluated, and their association with left ventricular geometry was determined. Patients with New York Heart Association Functional Classification greater than I, left ventricular ejection fraction less than 50%, history of coronary artery disease, severe valvulopathy, chronic atrial fibrillation, or creatinine clearance less than 30 ml/min, and those receiving insulin treatment, were excluded. Univariate analyses showed that relative wall thickness (RWT) was significantly correlated with diastolic blood pressure (P = 0.003), HbA1c (P = 0.024), total cholesterol (P = 0.043), urinary albumin (P = 0.023), and serum bilirubin concentration (P = 0.009). There was no association between left ventricular mass index and serum bilirubin concentration. Multivariate linear regression analysis showed that log RWT was positively correlated with diastolic blood pressure (P = 0.010) and that log RWT was inversely correlated with log bilirubin (P = 0.003). In addition, the patients with bilirubin less than 0.8 mg/dl had a higher prevalence of concentric left ventricular remodeling compared with those with bilirubin 0.8 mg/dl or more. Our study shows that the serum bilirubin concentration may be associated with the progression of concentric left ventricular remodeling in patients with type 2 diabetes mellitus.
Zheng, Huan; Xie, Nanzi; Xu, Huifeng; Huang, Junling; Xie, Xiaoyun; Luo, Ming
2016-03-01
We sought to investigate effects of supervised exercise training on left ventricular remodeling, left ventricular function and autonomic nervous system of hypertensive patients without medication. Fifty borderline and mildly hypertensive patients were enrolled and randomly divided into 2 groups (25 in each). Exercise group received a 4 months' exercise program, prescribed according to their first cardiopulmonary exercise tests, while the control group received routine dietary recommendation. All patients underwent noradrenalin assay, cardiopulmonary exercise tests and echocardiographic studies at enrollment and 4 month follow-up. At baseline no statistically difference between the two groups were observed in clinical characteristics, echographic variants or cardiopulmonary test index. Four months later, exercise group showed higher values of VO2peak, Powermax (max workload), AT (anaerobic threshold), VO2AT (VO2 at anaerobic threshold), tAT (time from beginning to anaerobic threshold) and heart rate recovery compared to the control group (P<0.05). Additionally, systolic/diastolic blood pressure decreased significantly in the exercise group compared to the control group (P<0.05). Moreover, there was significant reduction in left ventricular mass index in the exercise group (P<0.01), and there was also an inverse correlation between changes in left ventricular mass index and heart rate recovery (r=-0.52, P<0.01). Four-month exercise training in borderline and mildly hypertensive patients not only decreased their blood pressure levels, but also induced an improvement of exercise capability, left ventricular remodeling and heart rate recovery. Heart rate recovery improvement was significantly associated with decrease of left ventricular mass index, which indicated that favorable adjustment in autonomic nervous system of exercise training might be an important pathway to reverse left ventricular remodeling.
Colacino, Francesco Maria; Moscato, Francesco; Piedimonte, Fabio; Danieli, Guido; Nicosia, Salvatore; Arabia, Maurizio
2008-01-01
This article describes an elastance-based mock ventricle able to reproduce the correct ventricular pressure-volume relationship and its correct interaction with the hydraulic circuit connected to it. A real-time control of the mock ventricle was obtained by a new left ventricular mathematical model including resistive and inductive terms added to the classical Suga-Sagawa elastance model throughout the whole cardiac cycle. A valved piston pump was used to mimic the left ventricle. The pressure measured into the pump chamber was fed back into the mathematical model and the calculated reference left ventricular volume was used to drive the piston. Results show that the classical model is very sensitive to pressure disturbances, especially during the filling phase, while the modified model is able to filter out the oscillations thus eliminating their detrimental effects. The presented model is thus suitable to control mock ventricles in real-time, where sudden pressure disturbances represent a key issue and are not negligible. This real-time controlled mock ventricle is able to reproduce the elastance mechanism of a natural ventricle by mimicking its preload (mean atrial pressure) and afterload (mean aortic pressure) sensitivity, i.e., the Starling law. Therefore, it can be used for designing and testing cardiovascular prostheses due to its capability to reproduce the correct ventricle-vascular system interaction.
Walcott, Gregory; Melnick, Sharon; Killingsworth, Cheryl; Ideker, Raymond
2009-02-01
Although return of spontaneous circulation (ROSC) is frequently achieved during resuscitation for sudden cardiac arrest, systolic blood pressure can then decrease, requiring additional myocardial support. Previous studies have shown that a series of 1-ms electrical pulses delivered through the defibrillation patches during ventricular fibrillation (VF) can stimulate the autonomic nervous system to increase myocardial function following defibrillation. We hypothesized that a similar series of electrical pulses could increase myocardial function and blood pressure during the early post-resuscitation period. Six swine were studied that underwent 6-7 min. Each animal received 5, 10, 15, or 20 pulse packets consisting of 6 10 A, 1-ms pulses every 3-4 s in random order whenever systolic blood pressure became less than 50 mmHg. All four sets of pulse packets were delivered to each animal. Systolic blood pressure and cardiac function (left ventricular +dP/dt) were increased to pre-stimulation levels or above by all four sets of pulse packets. The increases were significantly greater for the longer than the shorter number of pulse packets. The mean+/-SD duration of the time that the systolic pressure remained above 50 mmHg following pulse delivery was 4.2+/-2.5 min. Electrical stimulation during regular rhythm following prolonged VF and resuscitation can increase blood pressure and cardiac function to above prestimulation levels.
Walcott, Gregory; Melnick, Sharon; Killingsworth, Cheryl; Ideker, Raymond
2009-01-01
Background Although return of spontaneous circulation (ROSC) is frequently achieved during resuscitation for sudden cardiac arrest, systolic blood pressure can then decrease, requiring additional myocardial support. Previous studies have shown that a series of 1-ms electrical pulses delivered through the defibrillation patches during ventricular fibrillation (VF) can stimulate the autonomic nervous system to increase myocardial function following defibrillation. We hypothesized that a similar series of electrical pulses could increase myocardial function and blood pressure during the early post-resuscitation period. Methods and Results Six swine were studied that underwent 6–7 min. Each animal received 5, 10, 15, or 20 pulse packets consisting of 6 10 A, 1-ms pulses every 3–4 s in random order whenever systolic blood pressure became less than 50 mmHg. All four sets of pulse packets were delivered to each animal. Systolic blood pressure and cardiac function (left ventricular +dP/dt) were increased to pre-stimulation levels or above by all four sets of pulse packets. The increases were significantly greater for the longer than the shorter number of pulse packets. The mean±SD duration of the time that the systolic pressure remained above 50 mmHg following pulse delivery was 4.2±2.5 min. Conclusions Electrical stimulation during regular rhythm following prolonged VF and resuscitation can increase blood pressure and cardiac function to above pre-arrest levels. PMID:19655042
Campbell, K B; Shroff, S G; Kirkpatrick, R D
1991-06-01
Based on the premise that short-time-scale, small-amplitude pressure/volume/outflow behavior of the left ventricular chamber was dominated by dynamic processes originating in cardiac myofilaments, a prototype model was built to predict pressure responses to volume perturbations. In the model, chamber pressure was taken to be the product of the number of generators in a pressure-bearing state and their average volumetric distortion, as in the muscle theory of A.F. Huxley, in which force was equal to the number of attached crossbridges and their average lineal distortion. Further, as in the muscle theory, pressure generators were assumed to cycle between two states, the pressure-bearing state and the non-pressure-bearing state. Experiments were performed in the isolated ferret heart, where variable volume decrements (0.01-0.12 ml) were removed at two commanded flow rates (flow clamps, -7 and -14 ml/sec). Pressure responses to volume removals were analyzed. Although the prototype model accounted for most features of the pressure responses, subtle but systematic discrepancies were observed. The presence or absence of flow and the magnitude of flow affected estimates of model parameters. However, estimates of parameters did not differ when the model was fitted to flow clamps with similar magnitudes of flows but different volume changes. Thus, prototype model inadequacies were attributed to misrepresentations of flow-related effects but not of volume-related effects. Based on these discrepancies, an improved model was built that added to the simple two-state cycling scheme, a pathway to a third state. This path was followed only in response to volume change. The improved model eliminated the deficiencies of the prototype model and was adequate in accounting for all observations. Since the template for the improved model was taken from the cycling crossbridge theory of muscle contraction, it was concluded that, in spite of the complexities of geometry, architecture, and regional heterogeneity of function and structure, crossbridge mechanisms dominated the short-time-scale dynamics of left ventricular chamber behavior.
Bi-ventricular finite element model of right ventricle overload in the healthy rat heart.
Masithulela, Fulufhelo
2016-11-25
The recognition of RV overpressure is critical to human life, as this may signify morbidity and mortality. Right ventricle (RV) dysfunction is understood to have an impact on the performance of the left ventricle (LV), but the mechanisms remain poorly understood. It is understood that ventricular compliance has the ability to affect cardiac performance. In this study, a bi-ventricular model of the rat heart was used in preference to other, single-ventricle models. Finite element analysis (FEA) of the bi-ventricular model provides important information on the function of the healthy heart. The passive myocardium was modelled as a nearly incompressible, hyperelastic, transversely isotropic material using finite element (FE) methods. Bi-ventricular geometries of healthy rat hearts reconstructed from magnetic resonance images were imported in Abaqus©. In simulating the normal passive filling of the rat heart, pressures of 4.8 kPa and 0.0098 kPa were applied to the inner walls of the LV and RV respectively. In addition, to simulate the overpressure of the RV, pressures of 2.4 kPa and 4.8 kPa were applied to the endocardial walls of the LV and RV respectively. As boundary conditions, the circumferential and longitudinal displacements at the base were set to zero. The radial displacements at the base were left free. The results show that the average circumferential stress at the mid-wall in the overloaded model increased from 2.8 kPa to 18.2 kPa. The average longitudinal stress increased from 1.5 kPa to 9.7 kPa. Additionally, in the radial direction, the average stress increased from 0.1 kPa to 0.6 kPa in the mid-wall. The average circumferential strain was found to be 0.138 and 0.100 on the endocardium of the over pressured and healthy model respectively. The average circumferential stress at the epicardium, mid-wall and endocardium in the case of a normal heart is 10 times lower than in the overloaded heart model. The finite analysis method is able to provide insights into the behaviour of the over pressured model (myocardium). In the overloaded model the high stresses and strains were observed on the septal wall. The bi-ventricular model was shown to provide useful information relating to the over pressured ventricle. The possible heart dysfunction may be attributable to high stress and strain in the over pressured heart.
Blast waves from violent explosive activity at Yasur Volcano, Vanuatu
NASA Astrophysics Data System (ADS)
Marchetti, E.; Ripepe, M.; Delle Donne, D.; Genco, R.; Finizola, A.; Garaebiti, E.
2013-11-01
and seismic waveforms were collected during violent strombolian activity at Yasur Volcano (Vanuatu). Averaging ~3000 seismic events showed stable waveforms, evidencing a low-frequency (0.1-0.3 Hz) signal preceding ~5-6 s the explosion. Infrasonic waveforms were mostly asymmetric with a sharp compressive (5-106 Pa) onset, followed by a small long-lasting rarefaction phase. Regardless of the pressure amplitude, the ratio between the positive and negative phases was constant. These waveform characteristics closely resembled blast waves. Infrared imagery showed an apparent cold spherical front ~20 m thick, which moved between 342 and 405 m/s before the explosive hot gas/fragments cloud. We interpret this cold front as that produced by the vapor condensation induced by the passage of the shock front. We suggest that violent strombolian activity at Yasur was driven by supersonic dynamics with gas expanding at 1.1 Mach number inside the conduit.
Acoustic Full Waveform Inversion to Characterize Near-surface Chemical Explosions
NASA Astrophysics Data System (ADS)
Kim, K.; Rodgers, A. J.
2015-12-01
Recent high-quality, atmospheric overpressure data from chemical high-explosive experiments provide a unique opportunity to characterize near-surface explosions, specifically estimating yield and source time function. Typically, yield is estimated from measured signal features, such as peak pressure, impulse, duration and/or arrival time of acoustic signals. However, the application of full waveform inversion to acoustic signals for yield estimation has not been fully explored. In this study, we apply a full waveform inversion method to local overpressure data to extract accurate pressure-time histories of acoustics sources during chemical explosions. A robust and accurate inversion technique for acoustic source is investigated using numerical Green's functions that take into account atmospheric and topographic propagation effects. The inverted pressure-time history represents the pressure fluctuation at the source region associated with the explosion, and thus, provides a valuable information about acoustic source mechanisms and characteristics in greater detail. We compare acoustic source properties (i.e., peak overpressure, duration, and non-isotropic shape) of a series of explosions having different emplacement conditions and investigate the relationship of the acoustic sources to the yields of explosions. The time histories of acoustic sources may refine our knowledge of sound-generation mechanisms of shallow explosions, and thereby allow for accurate yield estimation based on acoustic measurements. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
Hemodynamic transition driven by stent porosity in sidewall aneurysms.
Bouillot, Pierre; Brina, Olivier; Ouared, Rafik; Lovblad, Karl-Olof; Farhat, Mohamed; Pereira, Vitor Mendes
2015-05-01
The healing process of intracranial aneurysms (IAs) treated with flow diverter stents (FDSs) depends on the IA flow modifications and on the epithelization process over the neck. In sidewall IA models with straight parent artery, two main hemodynamic regimes with different flow patterns and IA flow magnitude were broadly observed for unstented and high porosity stented IA on one side, and low porosity stented IA on the other side. The hemodynamic transition between these two regimes is potentially involved in thrombosis formation. In the present study, CFD simulations and multi-time lag (MTL) particle imaging velocimetry (PIV) measurements were combined to investigate the physical nature of this transition. Measurable velocity fields and non-measurable shear stress and pressure fields were assessed experimentally and numerically in the aneurysm volume in the presence of stents with various porosities. The two main regimes observed in both PIV and CFD showed typical flow features of shear and pressure driven regimes. In particular, the waveform of the averaged IA velocities was matching both the shear stress waveform at IA neck or the pressure gradient waveform in parent artery. Moreover, the transition between the two regimes was controlled by stent porosity: a decrease of stent porosity leads to an increase (decrease) of pressure differential (shear stress) through IA neck. Finally, a good PIV-CFD agreement was found except in transitional regimes and low motion eddies due to small mismatch of PIV-CFD running conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.
Eide, Per Kristian; Holm, Sverre; Sorteberg, Wilhelm
2012-09-07
We recently reported that in an experimental setting the zero pressure level of solid intracranial pressure (ICP) sensors can be altered by electrostatics discharges. Changes in the zero pressure level would alter the ICP level (mean ICP); whether spontaneous changes in mean ICP happen in clinical settings is not known. This can be addressed by comparing the ICP parameters level and waveform of simultaneous ICP signals. To this end, we retrieved our recordings in patients with cerebral bleeds wherein the ICP had been recorded simultaneously from two different sensors. During a time period of 10 years, 17 patients with cerebral bleeds were monitored with two ICP sensors simultaneously; sensor 1 was always a solid sensor while Sensor 2 was a solid -, a fluid - or an air-pouch sensor. The simultaneous signals were analyzed with automatic identification of the cardiac induced ICP waves. The output was determined in consecutive 6-s time windows, both with regard to the static parameter mean ICP and the dynamic parameters (mean wave amplitude, MWA, and mean wave rise time, MWRT). Differences in mean ICP, MWA and MWRT between the two sensors were determined. Transfer functions between the sensors were determined to evaluate how sensors reproduce the ICP waveform. Comparing findings in two solid sensors disclosed major differences in mean ICP in 2 of 5 patients (40%), despite marginal differences in MWA, MWRT, and linear phase magnitude and phase. Qualitative assessment of trend plots of mean ICP and MWA revealed shifts and drifts of mean ICP in the clinical setting. The transfer function analysis comparing the solid sensor with either the fluid or air-pouch sensors revealed more variable transfer function magnitude and greater differences in the ICP waveform derived indices. Simultaneous monitoring of ICP using two solid sensors may show marked differences in static ICP but close to identity in dynamic ICP waveforms. This indicates that shifts in ICP baseline pressure (sensor zero level) occur clinically; trend plots of the ICP parameters also confirm this. Solid sensors are superior to fluid - and air pouch sensors when evaluating the dynamic ICP parameters.
10 CFR 431.282 - Test Procedures [Reserved
Code of Federal Regulations, 2010 CFR
2010-01-01
..., metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp..., current, and waveform) for starting and operating. High intensity discharge lamp means an electric... light is produced by radiation from mercury typically operating at a partial vapor pressure in excess of...
Jensen, Bjarke; Nyengaard, Jens R; Pedersen, Michael; Wang, Tobias
2010-12-01
The hearts of all snakes and lizards consist of two atria and a single incompletely divided ventricle. In general, the squamate ventricle is subdivided into three chambers: cavum arteriosum (left), cavum venosum (medial) and cavum pulmonale (right). Although a similar division also applies to the heart of pythons, this family of snakes is unique amongst snakes in having intracardiac pressure separation. Here we provide a detailed anatomical description of the cardiac structures that confer this functional division. We measured the masses and volumes of the ventricular chambers, and we describe the gross morphology based on dissections of the heart from 13 ball pythons (Python regius) and one Burmese python (P. molurus). The cavum venosum is much reduced in pythons and constitutes approximately 10% of the cavum arteriosum. We suggest that shunts will always be less than 20%, while other studies conclude up to 50%. The high-pressure cavum arteriosum accounted for approximately 75% of the total ventricular mass, and was twice as dense as the low-pressure cavum pulmonale. The reptile ventricle has a core of spongious myocardium, but the three ventricular septa that separate the pulmonary and systemic chambers--the muscular ridge, the bulbuslamelle and the vertical septum--all had layers of compact myocardium. Pythons, however, have unique pads of connective tissue on the site of pressure separation. Because the hearts of varanid lizards, which also are endowed with pressure separation, share many of these morphological specializations, we propose that intraventricular compact myocardium is an indicator of high-pressure systems and possibly pressure separation.
PULMONARY CIRCULATION AT EXERCISE
NAEIJE, R; CHESLER, N
2012-01-01
The pulmonary circulation is a high flow and low pressure circuit, with an average resistance of 1 mmHg.min.L−1 in young adults, increasing to 2.5 mmHg.min.L−1 over 4–6 decades of life. Pulmonary vascular mechanics at exercise are best described by distensible models. Exercise does not appear to affect the time constant of the pulmonary circulation or the longitudinal distribution of resistances. Very high flows are associated with high capillary pressures, up to a 20–25 mmHg threshold associated with interstitial lung edema and altered ventilation/perfusion relationships. Pulmonary artery pressures of 40–50 mmHg, which can be achieved at maximal exercise, may correspond to the extreme of tolerable right ventricular afterload. Distension of capillaries that decrease resistance may be of adaptative value during exercise, but this is limited by hypoxemia from altered diffusion/perfusion relationships. Exercise in hypoxia is associated with higher pulmonary vascular pressures and lower maximal cardiac output, with increased likelihood of right ventricular function limitation and altered gas exchange by interstitial lung edema. Pharmacological interventions aimed at the reduction of pulmonary vascular tone have little effect on pulmonary vascular pressure-flow relationships in normoxia, but may decrease resistance in hypoxia, unloading the right ventricle and thereby improving exercise capacity. Exercise in patients with pulmonary hypertension is associated with sharp increases in pulmonary artery pressure and a right ventricular limitation of aerobic capacity. Exercise stress testing to determine multipoint pulmonary vascular pressures-flow relationships may uncover early stage pulmonary vascular disease. PMID:23105961
Chang, Chun-Yi; Chang, Ru-Wen; Hsu, Shu-Hsien; Wu, Ming-Shiou; Cheng, Ya-Jung; Kao, Hsien-Li; Lai, Liang-Chuan; Wang, Chih-Hsien; Chang, Kuo-Chu
2017-01-01
Changes in vascular mechanics due to aging include elevated vascular impedance, diminished aorta distensibility, and an accelerated return of pulse wave reflection, which may increase the systolic workload on the heart. Classically, the accurate measurement of vascular mechanics requires the simultaneous recording of aortic pressure and flow signals. In practice, it is feasible to estimate arterial wave properties in terms of wave transit time (τ w ) and wave reflection index (RI) by using aortic pressure signal alone. In this study, we determined the τ w and magnitudes of the forward (∣ P f ∣) and backward (∣ P b ∣) pressure waves in Long-Evans male rats aged 4 ( n = 14), 6 ( n = 17), 12 ( n = 17), and 18 ( n = 24) months, based on the measured aortic pressure and an assumed triangular flow ( Q tri ). The pulsatile pressure wave was the only signal recorded in the ascending aorta by using a high-fidelity pressure sensor. The base of the unknown Q tri was constructed using a duration, which equals to the ejection time. The timing at the peak of the triangle was derived using the fourth-order derivative of the aortic pressure waveform. In the 18-month-old rats, the ratio of τ w to left ventricular ejection time (LVET) decreased, indicating a decline in the distensibility of the aorta. The increased ∣ P b ∣ associated with unaltered ∣ P f ∣ enhanced the RI in the older rats. The augmentation index (AI) also increased significantly with age. A significant negative correlation between the AI and τ w /LVET was observed: AI = -0.7424 - 0.9026 × (τ w /LVET) ( r = 0.4901; P < 0.0001). By contrast, RI was positively linearly correlated with the AI as follows: AI = -0.4844 + 2.3634 × RI ( r = 0.8423; P < 0.0001). Both the decreased τ w /LVET and increased RI suggested that the aging process may increase the AI, thereby increasing the systolic hydraulic load on the heart. The novelty of the study is that Q tri is constructed using the measured aortic pressure wave to approximate its corresponding flow signal, and that calibration of Q tri is not essential in the analysis.
Chang, Chun-Yi; Chang, Ru-Wen; Hsu, Shu-Hsien; Wu, Ming-Shiou; Cheng, Ya-Jung; Kao, Hsien-Li; Lai, Liang-Chuan; Wang, Chih-Hsien; Chang, Kuo-Chu
2017-01-01
Changes in vascular mechanics due to aging include elevated vascular impedance, diminished aorta distensibility, and an accelerated return of pulse wave reflection, which may increase the systolic workload on the heart. Classically, the accurate measurement of vascular mechanics requires the simultaneous recording of aortic pressure and flow signals. In practice, it is feasible to estimate arterial wave properties in terms of wave transit time (τw) and wave reflection index (RI) by using aortic pressure signal alone. In this study, we determined the τw and magnitudes of the forward (∣Pf∣) and backward (∣Pb∣) pressure waves in Long–Evans male rats aged 4 (n = 14), 6 (n = 17), 12 (n = 17), and 18 (n = 24) months, based on the measured aortic pressure and an assumed triangular flow (Qtri). The pulsatile pressure wave was the only signal recorded in the ascending aorta by using a high-fidelity pressure sensor. The base of the unknown Qtri was constructed using a duration, which equals to the ejection time. The timing at the peak of the triangle was derived using the fourth-order derivative of the aortic pressure waveform. In the 18-month-old rats, the ratio of τw to left ventricular ejection time (LVET) decreased, indicating a decline in the distensibility of the aorta. The increased ∣Pb∣ associated with unaltered ∣Pf∣ enhanced the RI in the older rats. The augmentation index (AI) also increased significantly with age. A significant negative correlation between the AI and τw/LVET was observed: AI = −0.7424 − 0.9026 × (τw/LVET) (r = 0.4901; P < 0.0001). By contrast, RI was positively linearly correlated with the AI as follows: AI = −0.4844 + 2.3634 × RI (r = 0.8423; P < 0.0001). Both the decreased τw/LVET and increased RI suggested that the aging process may increase the AI, thereby increasing the systolic hydraulic load on the heart. The novelty of the study is that Qtri is constructed using the measured aortic pressure wave to approximate its corresponding flow signal, and that calibration of Qtri is not essential in the analysis. PMID:28751867
Dekker, André L A J; Reesink, Koen D; van der Veen, Frederik H; van Ommen, G Vincent A; Geskes, Gijs G; Soemers, A Cecilia M; Maessen, Jos G
2003-04-01
Acute mitral regurgitation (MR) is present in 10% of patients presenting with cardiogenic shock. To stabilize these patients, intra-aortic balloon pumping (IABP) is recommended, but the mechanism of IABP support in these patients is unknown. This animal study was designed to describe the hemodynamic effect of intra-aortic balloon pumping during cardiogenic shock induced by acute MR. In eight calves, left ventricular pressure-volume loops, aortic and left atrial pressure, and aortic, carotid artery, and coronary blood flow were recorded. Acute MR (range 36%-79%) was created by placing a metal cage in the mitral valve. Hemodynamic data was obtained at control, during acute MR, and during acute MR with 1:1 IABP support. Acute MR caused a decrease in cardiac output (-32%, P = 0.018), blood pressure, and carotid artery flow, whereas left ventricular output (+127%, P = 0.018), end-diastolic volume, and left atrial pressure all significantly increased. Stroke work, ejection fraction, and coronary blood flow were not significantly changed, and no signs of ischemia were seen on the ECG. The IABP raised average cardiac output by 31% (P = 0.012) and significantly raised blood pressure and flow to the brain while decreasing systemic vascular resistance. Left ventricular function and mean coronary blood flow did not change, but diastolic coronary flow became more important as shown by the increase in diastolic fraction from 64% to 95%. (P = 0.028). Average MR dropped by 7.5% (P = 0.025). In conclusion, application of the IABP during acute MR lowers aortic impedance, resulting in less MR and more output toward the aorta without changing left ventricular function.
NASA Technical Reports Server (NTRS)
Koide, M.; Hamawaki, M.; Narishige, T.; Sato, H.; Nemoto, S.; DeFreyte, G.; Zile, M. R.; Cooper G, I. V.; Carabello, B. A.
2000-01-01
BACKGROUND: Because initially compensatory myocardial hypertrophy in response to pressure overloading may eventually decompensate to myocardial failure, mechanisms responsible for this transition have long been sought. One such mechanism established in vitro is densification of the cellular microtubule network, which imposes a viscous load that inhibits cardiocyte contraction. METHODS AND RESULTS: In the present study, we extended this in vitro finding to the in vivo level and tested the hypothesis that this cytoskeletal abnormality is important in the in vivo contractile dysfunction that occurs in experimental aortic stenosis in the adult dog. In 8 dogs in which gradual stenosis of the ascending aorta had caused severe left ventricular (LV) pressure overloading (gradient, 152+/-16 mm Hg) with contractile dysfunction, LV function was measured at baseline and 1 hour after the intravenous administration of colchicine. Cardiocytes obtained by biopsy before and after in vivo colchicine administration were examined in tandem. Microtubule depolymerization restored LV contractile function both in vivo and in vitro. CONCLUSIONS: These and additional corroborative data show that increased cardiocyte microtubule network density is an important mechanism for the ventricular contractile dysfunction that develops in large mammals with adult-onset pressure-overload-induced cardiac hypertrophy.
Schober, Karsten E; Rhinehart, Jaylyn; Kohnken, Rebecca; Bonagura, John D
2017-12-01
Combined cutting balloon and high-pressure balloon dilation was performed in a dog with a double-chambered right ventricle and severe infundibular stenosis of the right ventricular outflow tract. The peak systolic pressure gradient across the stenosis decreased by 65% after dilation (from 187 mmHg before to 66 mmHg after) affirming the intervention as successful. However, early re-stenosis occurred within 3 months leading to exercise intolerance, exercise-induced syncope, and right-sided congestive heart failure. Cutting balloon followed by high-pressure balloon dilation provided temporary but not long-term relief of right ventricular obstruction in this dog. Copyright © 2017 Elsevier B.V. All rights reserved.
Right ventricular involvement in cardiac sarcoidosis demonstrated with cardiac magnetic resonance.
Smedema, Jan-Peter; van Geuns, Robert-Jan; Ainslie, Gillian; Ector, Joris; Heidbuchel, Hein; Crijns, Harry J G M
2017-11-01
Cardiac involvement in sarcoidosis is reported in up to 30% of patients. Left ventricular involvement demonstrated by contrast-enhanced cardiac magnetic resonance has been well validated. We sought to determine the prevalence and distribution of right ventricular late gadolinium enhancement in patients diagnosed with pulmonary sarcoidosis. We prospectively evaluated 87 patients diagnosed with pulmonary sarcoidosis with contrast-enhanced cardiac magnetic resonance for right ventricular involvement. Pulmonary artery pressures were non-invasively evaluated with Doppler echocardiography. Patient characteristics were compared between the groups with and without right ventricular involvement, and right ventricular enhancement was correlated with pulmonary hypertension, ventricular mass, volume, and systolic function. Left ventricular late gadolinium enhancement was demonstrated in 30 patients (34%). Fourteen patients (16%) had right ventricular late gadolinium enhancement, with sole right ventricular enhancement in only two patients. The pattern of right ventricular enhancement consisted of right ventricular outflow tract enhancement in 1 patient, free wall enhancement in 8 patients, ventricular insertion point enhancement in 10 patients, and enhancement of the right side of the interventricular septum in 11 patients. Pulmonary arterial hypertension correlated with the presence of right ventricular enhancement (P < 0.001). Right ventricular enhancement correlated with systolic ventricular dysfunction (P < 0.001), hypertrophy (P = 0.001), and dilation (P < 0.001). Right ventricular enhancement was present in 16% of patients diagnosed with pulmonary sarcoidosis and in 48% of patients with left ventricular enhancement. The presence of right ventricular enhancement correlated with pulmonary arterial hypertension, right ventricular systolic dysfunction, hypertrophy, and dilation. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology.
Furihata, Kenji; Yamashita, Masato
2013-02-01
While occupational injury is associated with numerous individual and work-related risk factors, including long working hours and short sleep duration, the complex mechanisms causing such injuries are not yet fully understood. The relationship between the infrasound pressures of the tympanic membrane [ear canal pressure (ECP)], detected using an earplug embedded with a low-frequency microphone, and the carotid artery [carotid artery pressure (CAP)], detected using a stethoscope fitted with the same microphone, can be quantitatively characterized using systems analysis. The transfer functions of 40 normal workers (19 to 57 years old) were characterized, involving the analysis of 446 data points. The ECP waveform exhibits a pulsatile character with a slow respiratory component, which is superimposed on a biphasic recording that is synchronous with the cardiac cycle. The respiratory ECP waveform correlates with the instantaneous heart rate. The results also revealed that various fatigue-related risk factors may affect the mean magnitudes of the measured pressures and the delay transfer functions between CAP and ECP in the study population; these factors include systolic blood pressure, salivary amylase activity, age, sleep duration, postural changes, chronic fatigue, and pulse rate.
Transducer selection and application in magnetoacoustic tomography with magnetic induction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Yuqi; Wang, Jiawei; Ma, Qingyu, E-mail: maqingyu@njnu.edu.cn
2016-03-07
As an acoustic receiver, transducer plays a vital role in signal acquisition and image reconstruction for magnetoacoustic tomography with magnetic induction (MAT-MI). In order to optimize signal acquisition, the expressions of acoustic pressure detection and waveform collection are theoretically studied based on the radiation theory of acoustic dipole and the reception pattern of transducer. Pressure distributions are simulated for a cylindrical phantom model using a planar piston transducer with different radii and bandwidths. The proposed theory is also verified by the experimental measurements of acoustic waveform detection for an aluminum foil cylinder. It is proved that acoustic pressure with sharpmore » and clear boundary peaks can be detected by the large-radius transducer with wide bandwidth, reflecting the differential of the induced Lorentz force accurately, which is helpful for precise conductivity reconstruction. To detect acoustic pressure with acceptable pressure amplitude, peak pressure ratio, amplitude ratio, and improved signal to noise ratio, the scanning radius of 5–10 times the radius of the object should be selected to improve the accuracy of image reconstruction. This study provides a theoretical and experimental basis for transducer selection and application in MAT-MI to obtain reconstructed images with improved resolution and definition.« less
A Fiber Bragg Grating Sensor for Radial Artery Pulse Waveform Measurement.
Jia, Dagong; Chao, Jing; Li, Shuai; Zhang, Hongxia; Yan, Yingzhan; Liu, Tiegen; Sun, Ye
2018-04-01
In this paper, we report the design and experimental validation of a novel optical sensor for radial artery pulse measurement based on fiber Bragg grating (FBG) and lever amplification mechanism. Pulse waveform analysis is a diagnostic tool for clinical examination and disease diagnosis. High fidelity radial artery pulse waveform has been investigated in clinical studies for estimating central aortic pressure, which is proved to be predictors of cardiovascular diseases. As a three-dimensional cylinder, the radial artery needs to be examined from different locations to achieve optimal pulse waveform for estimation and diagnosis. The proposed optical sensing system is featured as high sensitivity and immunity to electromagnetic interference for multilocation radial artery pulse waveform measurement. The FBG sensor can achieve the sensitivity of 8.236 nm/N, which is comparable to a commonly used electrical sensor. This FBG-based system can provide high accurate measurement, and the key characteristic parameters can be then extracted from the raw signals for clinical applications. The detecting performance is validated through experiments guided by physicians. In the experimental validation, we applied this sensor to measure the pulse waveforms at various positions and depths of the radial artery in the wrist according to the diagnostic requirements. The results demonstrate the high feasibility of using optical systems for physiological measurement and using this FBG sensor for radial artery pulse waveform in clinical applications.
Wang, Yali; Hu, Feng; Mu, Xiaoyan; Wu, Feng; Yang, Dechun; Zheng, Guixiang; Sun, Xiaoning; Gong, Kaizheng; Zhang, Zhengang
2016-01-27
Drag-reducing polymers (DRPs) are blood-soluble macromolecules which may increase blood flow and reduce vascular resistance. The purpose of the present study was to observe the effect of DRPs on monocrotaline-induced pulmonary hypertension (PH) in the rat model. A total of 64 male Wistar rats were randomly divided into four groups: Group I (pulmonary hypertension model + DRP treatment); Group II (pulmonary hypertension model + saline treatment); Group III (control + DRP treatment); Group IV (control + saline treatment). After five weeks, comparisons were made of the following indices: survival rate, body weight, blood pressure, right ventricular systolic pressure, right ventricular hypertrophy, wall thickness of pulmonary arteries, the internal diameter of small pulmonary arteries, plasma IL-1β and IL-6. The survival rate after 5 weeks varied significantly across all groups (P=0.013), but the survival rates of Groups I and II were not statistically significantly different. Administration of DRP (intravenous injection twice weekly) attenuated the PH-induced increase in right ventricular systolic pressure and suppressed the increases in right ventricular (RV) weight and the ratio of right ventricular weight to left ventricle plus septum weight (RV/LV + S). DRP treatment also significantly decreased the wall thickness of pulmonary arteries, augmented the internal diameter of small pulmonary arteries, and suppressed increases in the plasma levels of IL-1β and IL-6. DRP treatment with intravenous injection effectively inhibited the development of monocrotaline-induced pulmonary hypertension in the rat model. DRPs may have potential application for the treatment of pulmonary hypertension.
The myth of the Bernheim syndrome.
Chung, Monica S; Ko, Jo Mi; Chamogeorgakis, Themistokles; Hall, Shelley A; Roberts, William C
2013-10-01
The Bernheim syndrome has been a topic of discussion for over a century. It has been reported to be caused by severe rightward movement of the ventricular septum resulting in compression of the right ventricular cavity leading to right-sided heart failure without pulmonary congestion. Hemodynamic findings have been described in a few patients with the so-called Bernheim syndrome. We describe a patient in whom the ventricular septum dramatically decreased the size of the right ventricular cavity and yet peak systolic pressures in both the right ventricle and pulmonary trunk were identical. Thus, it is difficult to view the Bernheim syndrome as a real entity.
Noninvasive intracranial pressure measurement using infrasonic emissions from the tympanic membrane.
Stettin, Eduard; Paulat, Klaus; Schulz, Chris; Kunz, Ulrich; Mauer, Uwe Max
2011-06-01
We investigated whether ICP can be assessed by measuring infrasonic emissions from the tympanic membrane. An increase in ICP was induced in 22 patients with implanted ICP pressure sensors. ICP waveforms that were obtained invasively and continuously were compared with infrasonic emission waveforms. In addition, the noninvasive method was used in a control group of 14 healthy subjects. In a total of 83 measurements, the changes in ICP that were observed in response to different types of stimulation were detected in the waveforms obtained noninvasively as well as in those acquired invasively. Low ICP was associated with an initial high peak and further peaks with smaller amplitudes. High ICP was associated with a marked decrease in the number of peaks and in the difference between the amplitudes of the initial and last peaks. The assessment of infrasonic emissions, however, does not yet enable us to provide exact figures. It is conceivable that the assessment of infrasonic emissions will become suitable both as a screening tool and for the continuous monitoring of ICP in an intensive care environment.
Clinical applications of angiocardiography
NASA Technical Reports Server (NTRS)
Dodge, H. T.; Sandler, H.
1974-01-01
Several tables are presented giving left ventricular (LV) data for normal patients and patients with heart disease of varied etiologies, pointing out the salient features. Graphs showing LV pressure-volume relationships (compliance) are presented and discussed. The method developed by Rackley et al. (1964) for determining left ventricular mass in man is described, and limitations to the method are discussed. Some clinical methods for determining LV oxygen consumption are briefly described, and the relation of various abnormalities of ventricular performance to coronary artery disease and ischemic heart disease is characterized.
... or in combination with other medications to treat high blood pressure. Losartan is also used to decrease the risk of stroke in people who have high blood pressure and a heart condition called left ventricular hypertrophy ( ...
Free-field propagation of high intensity noise
NASA Technical Reports Server (NTRS)
Welz, Joseph P.; Mcdaniel, Oliver H.
1990-01-01
Observed spectral data from supersonic jet aircraft are known to contain much more high frequency energy than can be explained by linear acoustic propagation theory. It is believed that the high frequency energy is an effect of nonlinear distortion due to the extremely high acoustic levels generated by the jet engines. The objective, to measure acoustic waveform distortion for spherically diverging high intensity noise, was reached by using an electropneumatic acoustic source capable of generating sound pressure levels in the range of 140 to 160 decibels (re 20 micro Pa). The noise spectrum was shaped to represent the spectra generated by jet engines. Two microphones were used to capture the acoustic pressure waveform at different points along the propagation path in order to provide a direct measure of the waveform distortion as well as spectral distortion. A secondary objective was to determine that the observed distortion is an acoustic effect. To do this an existing computer prediction code that deals with nonlinear acoustic propagation was used on data representative of the measured data. The results clearly demonstrate that high intensity jet noise does shift the energy in the spectrum to the higher frequencies along the propagation path. In addition, the data from the computer model are in good agreement with the measurements, thus demonstrating that the waveform distortion can be accounted for with nonlinear acoustic theory.
Swarms of repeating long-period earthquakes at Shishaldin Volcano, Alaska, 2001-2004
Petersen, Tanja
2007-01-01
During 2001–2004, a series of four periods of elevated long-period seismic activity, each lasting about 1–2 months, occurred at Shishaldin Volcano, Aleutian Islands, Alaska. The time periods are termed swarms of repeating events, reflecting an abundance of earthquakes with highly similar waveforms that indicate stable, non-destructive sources. These swarms are characterized by increased earthquake amplitudes, although the seismicity rate of one event every 0.5–5 min has remained more or less constant since Shishaldin last erupted in 1999. A method based on waveform cross-correlation is used to identify highly repetitive events, suggestive of spatially distinct source locations. The waveform analysis shows that several different families of similar events co-exist during a given swarm day, but generally only one large family dominates. A network of hydrothermal fractures may explain the events that do not belong to a dominant repeating event group, i.e. multiple sources at different locations exist next to a dominant source. The dominant waveforms exhibit systematic changes throughout each swarm, but some of these waveforms do reappear over the course of 4 years indicating repeatedly activated source locations. The choked flow model provides a plausible trigger mechanism for the repeating events observed at Shishaldin, explaining the gradual changes in waveforms over time by changes in pressure gradient across a constriction within the uppermost part of the conduit. The sustained generation of Shishaldin's long-period events may be attributed to complex dynamics of a multi-fractured hydrothermal system: the pressure gradient within the main conduit may be regulated by temporarily sealing and reopening of parallel flow pathways, by the amount of debris within the main conduit and/or by changing gas influx into the hydrothermal system. The observations suggest that Shishaldin's swarms of repeating events represent time periods during which a dominant source is activated.
Arnuntasupakul, Vanlapa; Van Zundert, Tom C R V; Vijitpavan, Amorn; Aliste, Julian; Engsusophon, Phatthanaphol; Leurcharusmee, Prangmalee; Ah-Kye, Sonia; Finlayson, Roderick J; Tran, De Q H
2016-01-01
Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for loss of resistance (LOR): when the needle tip is correctly positioned inside the epidural space, pressure measurement results in a pulsatile waveform. In this randomized trial, we compared conventional and EWA-confirmed LOR in 2 teaching centers. Our research hypothesis was that EWA-confirmed LOR would decrease the failure rate of thoracic epidural blocks. One hundred patients undergoing thoracic epidural blocks for thoracic surgery, abdominal surgery, or rib fractures were randomized to conventional LOR or EWA-LOR. The operator was allowed as many attempts as necessary to achieve a satisfactory LOR (by feel) in the conventional group. In the EWA-LOR group, LOR was confirmed by connecting the epidural needle to a pressure transducer using a rigid extension tubing. Positive waveforms indicated that the needle tip was positioned inside the epidural space. The operator was allowed a maximum of 3 different intervertebral levels to obtain a positive waveform. If waveforms were still absent at the third level, the operator simply accepted LOR as the technical end point. However, the patient was retained in the EWA-LOR group (intent-to-treat analysis).After achieving a satisfactory tactile LOR (conventional group), positive waveforms (EWA-LOR group), or a third intervertebral level with LOR but no waveform (EWA-LOR group), the operator administered a 4-mL test dose of lidocaine 2% with epinephrine 5 μg/mL. Fifteen minutes after the test dose, a blinded investigator assessed the patient for sensory block to ice. Compared with LOR, EWA-LOR resulted in a lower rate of primary failure (2% vs 24%; P = 0.002). Subgroup analysis based on experience level reveals that EWA-LOR outperformed conventional LOR for novice (P = 0.001) but not expert operators. The performance time was longer in the EWA-LOR group (11.2 ± 6.2 vs 8.0 ± 4.6 minutes; P = 0.006). Both groups were comparable in terms of operator's level of expertise, depth of the epidural space, approach, and LOR medium. In the EWA-LOR group, operators obtained a pulsatile waveform with the first level attempted in 60% of patients. However, 40% of subjects required performance at a second or third level. Compared with its conventional counterpart, EWA-confirmed LOR results in a lower failure rate for thoracic epidural blocks (2% vs 24%) in our teaching centers. Confirmatory EWA provides significant benefits for inexperienced operators.
Remote Blood Pressure Waveform Sensing Method and Apparatus
2008-06-02
test the effects of drugs, exercise, or other stimuli, whereby an increase or decrease in the ratio may indicate an improvement or worsening of systolic...even though high blood pressure in animals can be symptomatic of a variety of diseases including chronic renal failure, hyperthyroidism , Cushing’s
Mair, Rudolf; Tulzer, Gerald; Sames, Eva; Gitter, Roland; Lechner, Evelyn; Steiner, Jürgen; Hofer, Anna; Geiselseder, Gertraud; Gross, Christoph
2003-11-01
Perioperative mortality, prolonged postoperative recovery after the Norwood procedure, and mortality between stage I and stage II might be related to shunt physiology. A right ventricular to pulmonary artery conduit offers a banded physiology in contrast to a Blalock-Taussig shunt. The purpose of this study was to assess the hemodynamic differences and their consequences in the postoperative course between Norwood patients with a Blalock-Taussig shunt and those with a right ventricular to pulmonary artery conduit. From October 1999 until May 2002, 32 unselected consecutive patients underwent a Norwood procedure at the General Hospital Linz. The first 18 patients received a Blalock-Taussig shunt. In the remaining 14 patients we performed a right ventricular to pulmonary artery conduit. Both groups were compared. The diastolic blood pressure was significantly higher in the right ventricular to pulmonary artery conduit group (P <.001). Despite a higher FIO(2), PO(2) levels tended to be lower in the first 5 postoperative days. At the age of 3 months, catheterization laboratory data showed a lower Qp/Qs ratio in the same group (0.86 [0.78; 1] versus 1.55 [1.15; 1.6]; P =.005) and a higher dp/dt (955 [773; 1110] vs 776 [615; 907]; P =.018). (Descriptive data reflect medians and quartiles [in brackets].) Hospital survival was 72% in the Blalock-Taussig shunt group versus 93% in the right ventricular to pulmonary artery conduit group. Mortality between stage I and stage II was 23% in the Blalock-Taussig shunt group versus 0% in the right ventricular to pulmonary artery conduit group. A higher diastolic blood pressure and a lower Qp/Qs ratio were associated with a more stable and efficient circulation in patients with a right ventricular to pulmonary artery conduit. More intensive ventilatory support was necessary during the first postoperative days. We did not note any adverse effects of the ventriculotomy on ventricular performance.
Nekooeian, A A; Tabrizchi, R
1998-10-01
1. Recently we demonstrated that the administration of an A2A adenosine receptor agonist, CGS 21680, to anaesthetized rats with acute heart failure (1 h post-coronary artery ligation) resulted in an increase in cardiac output. In the present investigation, the effects of CGS 21680 on cardiac output, vascular resistance, heart rate, blood pressure and mean circulatory filling pressure (Pmcf) were investigated in anaesthetized rats with chronic heart failure (8 weeks post-coronary artery ligation). 2. Experiments were conducted in five groups (n = 6) of animals: sham-operated vehicle-treated (0.9% NaCl; 0.037 mL kg(-1) min(-1)) animals in which the occluder was placed but not pulled to ligate the coronary artery; coronary artery-ligated vehicle-treated animals; and coronary artery-ligated CGS 21680-treated (0.1. 0.3 or 1.0 microg kg(-1) min(-1)) animals. 3. Baseline blood pressure, cardiac output and rate of rise in left ventricular pressure (+dP/dt) were significantly reduced in animals with coronary artery ligation when compared to sham-operated animals. Coronary artery ligation resulted in a significant increase in left ventricular end-diastolic pressure, Pmcf and venous resistance when compared to sham-operated animals. 4. Administration of CGS 21680 at 0.3 and 1.0 microg kg(-1) min(-1) significantly (n = 6; P<0.05) increased cardiac output by 19+/-4% and 39+/-5%, and heart rate by 14+/-2% and 15+/-1%, respectively, when compared to vehicle treatment in coronary artery-ligated animals. Administration of CGS 21680 also significantly reduced blood pressure and arterial resistance when compared to coronary artery-ligated vehicle-treated animals. Infusion of CGS 21680 also significantly reduced venous resistance when compared to vehicle-treated coronary artery-ligated animals. 5. The results show that heart failure is characterized by reduced cardiac output, and increased left ventricular end-diastolic pressure, venous resistance and Pmcf. Acute treatment with CGS 21680 in animals with chronic heart failure decreased left ventricular end-diastolic pressure and increased cardiac output. This increase in cardiac output was the result of reduced arterial and venous resistances and increased heart rate.
Law, Yuk M; Keller, Bradley B; Feingold, Brian M; Boyle, Gerard J
2005-02-15
The usefulness of B-type natriuretic peptide (BNP) levels to assess ventricular dysfunction in children and the congenital heart disease population remains largely unknown. We retrospectively analyzed 62 patients with or without known heart disease who had plasma BNP measured for the investigation of new or severity grading of known ventricular dysfunction. BNP levels were significantly higher in patients with ventricular dysfunction (mean 623 +/- 146 pg/ml, range 5 to 5,000) than in patients without ventricular dysfunction (mean 22 +/- 5 pg/ml, range 5 to 63; p <0.01). Using a cutoff of 40 pg/ml, BNP levels detected heart disease associated with ventricular dysfunction at a sensitivity of 85%, specificity of 81%, positive predictive value of 92%, and negative predictive value of 68%. The degree of BNP elevation was also associated with the severity of heart failure and high ventricular filling pressures. Plasma BNP elevation can be a reliable test in children and young adults with various kinds of congenital heart disease resulting in ventricular dysfunction.
Assessment of central haemomodynamics from a brachial cuff in a community setting
2012-01-01
Background Large artery stiffening and wave reflections are independent predictors of adverse events. To date, their assessment has been limited to specialised techniques and settings. A new, more practical method allowing assessment of central blood pressure from waveforms recorded using a conventional automated oscillometric monitor has recently been validated in laboratory settings. However, the feasibility of this method in a community based setting has not been assessed. Methods One-off peripheral and central haemodynamic (systolic and diastolic blood pressure (BP) and pulse pressure) and wave reflection parameters (augmentation pressure (AP) and index, AIx) were obtained from 1,903 volunteers in an Austrian community setting using a transfer-function like method (ARCSolver algorithm) and from waveforms recorded with a regular oscillometric cuff. We assessed these parameters for known differences and associations according to gender and age deciles from <30 years to >80 years in the whole population and a subset with a systolic BP < 140 mmHg. Results We obtained 1,793 measures of peripheral and central BP, PP and augmentation parameters. Age and gender associations with central haemodynamic and augmentation parameters reflected those previously established from reference standard non-invasive techniques under specialised settings. Findings were the same for patients with a systolic BP below 140 mmHg (i.e. normotensive). Lower values for AIx in the current study are possibly due to differences in sampling rates, detection frequency and/or averaging procedures and to lower numbers of volunteers in younger age groups. Conclusion A novel transfer-function like algorithm, using brachial cuff-based waveform recordings, provides robust and feasible estimates of central systolic pressure and augmentation in community-based settings. PMID:22734820
Hughes, William E; Ueda, Kenichi; Treichler, David P; Casey, Darren P
2016-09-30
Aging is associated with elevated blood pressure (peripheral and aortic; BP) and aortic augmentation index (AIx) which may contribute to aortic BP. Although inorganic nitrate consumption reduces peripheral BP in both young and older adults, the effects of nitrate consumption on aortic BP and wave reflection in young and older adults is unknown. Therefore, we sought to characterize the effects of nitrate consumption on aortic BP and AIx in young and older adults. Noninvasive aortic pressure waveforms were synthesized from high-fidelity radial pressure waveforms via applanation tonometry before and following (60, 90, 120, 150, and 180 min) consumption of a nitrate-rich beetroot juice in 26 healthy adults (young: 25 ± 4 years, n = 14; older: 64 ± 5 years, n = 12). Aortic BP and indices of aortic wave reflection (AIx and AIx normalized for heart rate; AIx@75bpm) were calculated from the generated aortic pressure waveform. Nitrate consumption increased plasma nitrite in both groups 60-180 min following beetroot consumption (P < 0.001). Nitrate consumption reduced peripheral and aortic BP in both young and older adults (P < 0.05), with the change being similar between age groups. Conversely, indices of aortic wave reflection were reduced only in young adults following nitrate consumption (range of change from baseline over time: AIx@75bpm, -4.3 to -8.8%, P < 0.05), whereas aortic AIx remained unchanged in the older adults. Taken together, our results suggest that acute dietary nitrate supplementation reduces peripheral and aortic BP similarly in young and older adults despite differential effects on aortic AIx between age groups. Copyright © 2016 Elsevier Inc. All rights reserved.
Duchna, Hans-Werner; Myslinski, Wojciech; Dichmann, Manuel; Rasche, Kurt; Schultze-Werninghaus, Gerhard; Orth, Maritta
2006-01-15
30% of patients with arterial hypertension (AH) are supposed to have a co-prevalent obstructive sleep apnea syndrome (OSAS). Hence, the influence of CPAP (continuous positive airway pressure) therapy on cardiac structure and function was investigated in medically treated patients with AH and co-prevalent OSAS. In all patients AH was treated for at least 5 years. Matched pairs concerning anthropometric data, medical therapy and duration of AH, and severity of OSAS were investigated: 20 patients with untreated OSAS were compared to 20 patients with CPAP therapy for at least 6 months. Further cardiopulmonary diseases were excluded. Cardiac structure and function were assessed echocardiographically. Patients under CPAP therapy had significantly better diastolic left ventricular function, a lower left ventricular mass index, and significantly less frequent signs of left ventricular (eccentric) hypertrophy than patients with untreated OSAS. Furthermore, differences were significant concerning right ventricular wall thickness and mean pulmonary artery pressure. CPAP therapy positively influences left and right cardial structure and function in addition to antihypertensive medication in patients with AH and co-prevalent OSAS.
Right Ventricular Hemodynamics in Patients with Pulmonary Hypertension
NASA Astrophysics Data System (ADS)
Browning, James; Fenster, Brett; Hertzberg, Jean; Schroeder, Joyce
2012-11-01
Recent advances in cardiac magnetic resonance imaging (CMR) have allowed for characterization of blood flow in the right ventricle (RV), including calculation of vorticity and circulation, and qualitative visual assessment of coherent flow patterns. In this study, we investigate qualitative and quantitative differences in right ventricular hemodynamics between subjects with pulmonary hypertension (PH) and normal controls. Fifteen (15) PH subjects and 10 age-matched controls underwent same day 3D time resolved CMR and echocardiography. Echocardiography was used to determine right ventricular diastolic function as well as pulmonary artery systolic pressure (PASP). Velocity vectors, vorticity vectors, and streamlines in the RV were visualized in Paraview and total RV Early (E) and Atrial (A) wave diastolic vorticity was quantified. Visualizations of blood flow in the RV are presented for PH and normal subjects. The hypothesis that PH subjects exhibit different RV vorticity levels than normals during diastole is tested and the relationship between RV vorticity and PASP is explored. The mechanics of RV vortex formation are discussed within the context of pulmonary arterial pressure and right ventricular diastolic function coincident with PH.
Evaluation of Cardiovascular Risk Factors in the Wistar Audiogenic Rat (WAR) Strain
Fazan, Rubens; Silva, Carlos Alberto A.; Oliveira, José Antônio Cortes; Salgado, Helio Cesar; Montano, Nicola; Garcia-Cairasco, Norberto
2015-01-01
Introduction Risk factors for life-threatening cardiovascular events were evaluated in an experimental model of epilepsy, the Wistar Audiogenic Rat (WAR) strain. Methods We used long-term ECG recordings in conscious, one year old, WAR and Wistar control counterparts to evaluate spontaneous arrhythmias and heart rate variability, a tool to assess autonomic cardiac control. Ventricular function was also evaluated using the pressure-volume conductance system in anesthetized rats. Results Basal RR interval (RRi) was similar between WAR and Wistar rats (188±5 vs 199±6 ms). RRi variability strongly suggests that WAR present an autonomic imbalance with sympathetic overactivity, which is an isolated risk factor for cardiovascular events. Anesthetized WAR showed lower arterial pressure (92±3 vs 115±5 mmHg) and exhibited indices of systolic dysfunction, such as higher ventricle end-diastolic pressure (9.2±0.6 vs 5.6±1 mmHg) and volume (137±9 vs 68±9 μL) as well as lower rate of increase in ventricular pressure (5266±602 vs 7320±538 mmHg.s-1). Indices of diastolic cardiac function, such as lower rate of decrease in ventricular pressure (-5014±780 vs -7766±998 mmHg.s-1) and a higher slope of the linear relationship between end-diastolic pressure and volume (0.078±0.011 vs 0.036±0.011 mmHg.μL), were also found in WAR as compared to Wistar control rats. Moreover, Wistar rats had 3 to 6 ventricular ectopic beats, whereas WAR showed 15 to 30 ectopic beats out of the 20,000 beats analyzed in each rat. Conclusions The autonomic imbalance observed previously at younger age is also present in aged WAR and, additionally, a cardiac dysfunction was also observed in the rats. These findings make this experimental model of epilepsy a valuable tool to study risk factors for cardiovascular events in epilepsy. PMID:26029918
Molina, Ezequiel J; Palma, Jon; Gupta, Dipin; Torres, Denise; Gaughan, John P; Houser, Steven; Macha, Mahender
2008-02-01
In a rat model of pressure overload hypertrophy, we studied the effects of intracoronary delivery of mesenchymal stem cells on hemodynamic performance, exercise capacity, systemic inflammation, and left ventricular reverse remodeling. Sprague-Dawley rats underwent aortic banding and were followed up by echocardiographic scanning. After a decrease in fractional shortening of 25% from baseline, animals were randomized to intracoronary injection of mesenchymal stem cells (MSC group; n = 28) or phosphate-buffered saline solution (control group; n = 20). Hemodynamic and echocardiographic assessment, swim testing to exhaustion, and measurement of inflammatory markers were performed before the rats were humanely killed on postoperative day 7, 14, 21, or 28. Injection of mesenchymal stem cells improved systolic function in the MSC group compared with the control group (mean +/- standard deviation: maximum dP/dt 3048 +/- 230 mm Hg/s vs 2169 +/- 97 mm Hg/s at 21 days and 3573 +/- 741 mm Hg/s vs 1363 +/- 322 mm Hg/s at 28 days: P < .001). Time to exhaustion was similarly increased in the MSC group compared with controls (487 +/- 35 seconds vs 306 +/- 27 seconds at 28 days; P < .01). Serum levels of interleukins 1 and 6, tumor necrosis factor-alpha, and brain natriuretic peptide-32 were significantly decreased in animals treated with mesenchymal stem cells. Stem cell transplantation improved left ventricular fractional shortening at 21 and 28 days. Left ventricular end-systolic and end-diastolic diameters were also improved at 28 days. In this model of pressure overload hypertrophy, intracoronary delivery of mesenchymal stem cells during heart failure was associated with an improvement in hemodynamic performance, maximal exercise tolerance, systemic inflammation, and left ventricular reverse remodeling. This study suggests a potential role of this treatment strategy for the management of hypertrophic heart failure resulting from pressure overload.
Sacco, Federica; Paun, Bruno; Lehmkuhl, Oriol; Iles, Tinen L.; Iaizzo, Paul A.; Houzeaux, Guillaume; Vázquez, Mariano; Butakoff, Constantine; Aguado-Sierra, Jazmin
2018-01-01
The aim of the present study is to characterize the hemodynamics of left ventricular (LV) geometries to examine the impact of trabeculae and papillary muscles (PMs) on blood flow using high performance computing (HPC). Five pairs of detailed and smoothed LV endocardium models were reconstructed from high-resolution magnetic resonance images (MRI) of ex-vivo human hearts. The detailed model of one LV pair is characterized only by the PMs and few big trabeculae, to represent state of art level of endocardial detail. The other four detailed models obtained include instead endocardial structures measuring ≥1 mm2 in cross-sectional area. The geometrical characterizations were done using computational fluid dynamics (CFD) simulations with rigid walls and both constant and transient flow inputs on the detailed and smoothed models for comparison. These simulations do not represent a clinical or physiological scenario, but a characterization of the interaction of endocardial structures with blood flow. Steady flow simulations were employed to quantify the pressure drop between the inlet and the outlet of the LVs and the wall shear stress (WSS). Coherent structures were analyzed using the Q-criterion for both constant and transient flow inputs. Our results show that trabeculae and PMs increase the intra-ventricular pressure drop, reduce the WSS and disrupt the dominant single vortex, usually present in the smoothed-endocardium models, generating secondary small vortices. Given that obtaining high resolution anatomical detail is challenging in-vivo, we propose that the effect of trabeculations can be incorporated into smoothed ventricular geometries by adding a porous layer along the LV endocardial wall. Results show that a porous layer of a thickness of 1.2·10−2 m with a porosity of 20 kg/m2 on the smoothed-endocardium ventricle models approximates the pressure drops, vorticities and WSS observed in the detailed models. PMID:29760665
Protective effects of naringenin in cardiorenal syndrome.
Liu, Yan; An, Wenjun; Gao, Aibao
2016-06-15
Cardiorenal syndrome is a complicated and bidirectional interrelationship between the heart and kidneys. Naringenin (NG) is a naturally occurring flavonoid possessing various biological and pharmacological properties. We tested whether NG could improve cardiac and renal function in a rat model of cardiorenal syndrome. The results showed that NG-attenuated cardiac remodeling and cardiac dysfunction in rats with cardiorenal syndrome, as evidenced by decrease of left ventricle weight (LVW), increase of body weight (BW), decrease of LVW/BW, decrease of concentrations of serum creatinine, blood urea nitrogen, type-B natriuretic peptide, aldosterone, angiotensin (Ang) II, C-reactive protein, and urine protein, increase of left ventricular systolic pressure and falling rates of left ventricular pressure (dp/dtmax), and decrease of left ventricular diastolic pressure, left ventricular end-diastolic pressure, and -dp/dtmax. NG significantly inhibited the increase of lipid profiles including low-density lipoprotein, TC, and TG in rats. In addition, NG significantly inhibited the increase of cardiac expression of IL-1β, IL-6, and interferon γ. Moreover, NG decreased malonaldehyde level, increased superoxide dismutase activity and glutathione content in rats, and increased the expression of nuclear factor erythroid 2-related factor 2 (Nrf2) and catalytic subunit of γ-glutamylcysteine ligase (GCLc) in rats and Ang II-treated cardiac fibroblasts. Inhibition of Nrf2 and glutathione synthesis significantly suppressed NG-induced decrease of ROS level. Inhibition of Nrf2 markedly suppressed NG-induced increase of GCLc expression in Ang II-treated cardiac fibroblasts. The data provide novel options for therapy of patients and new insights into the cardioprotective effects of NG in cardiorenal syndrome. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Johnsson, Roger
2006-11-01
Methods to measure and monitor the cylinder pressure in internal combustion engines can contribute to reduced fuel consumption, noise and exhaust emissions. As direct measurements of the cylinder pressure are expensive and not suitable for measurements in vehicles on the road indirect methods which measure cylinder pressure have great potential value. In this paper, a non-linear model based on complex radial basis function (RBF) networks is proposed for the reconstruction of in-cylinder pressure pulse waveforms. Input to the network is the Fourier transforms of both engine structure vibration and crankshaft speed fluctuation. The primary reason for the use of Fourier transforms is that different frequency regions of the signals are used for the reconstruction process. This approach also makes it easier to reduce the amount of information that is used as input to the RBF network. The complex RBF network was applied to measurements from a 6-cylinder ethanol powered diesel engine over a wide range of running conditions. Prediction accuracy was validated by comparing a number of parameters between the measured and predicted cylinder pressure waveform such as maximum pressure, maximum rate of pressure rise and indicated mean effective pressure. The performance of the network was also evaluated for a number of untrained running conditions that differ both in speed and load from the trained ones. The results for the validation set were comparable to the trained conditions.
Fault Slip Distribution of the 2016 Fukushima Earthquake Estimated from Tsunami Waveforms
NASA Astrophysics Data System (ADS)
Gusman, Aditya Riadi; Satake, Kenji; Shinohara, Masanao; Sakai, Shin'ichi; Tanioka, Yuichiro
2017-08-01
The 2016 Fukushima normal-faulting earthquake (Mjma 7.4) occurred 40 km off the coast of Fukushima within the upper crust. The earthquake generated a moderate tsunami which was recorded by coastal tide gauges and offshore pressure gauges. First, the sensitivity of tsunami waveforms to fault dimensions and depths was examined and the best size and depth were determined. Tsunami waveforms computed based on four available focal mechanisms showed that a simple fault striking northeast-southwest and dipping southeast (strike = 45°, dip = 41°, rake = -95°) yielded the best fit to the observed waveforms. This fault geometry was then used in a tsunami waveform inversion to estimate the fault slip distribution. A large slip of 3.5 m was located near the surface and the major slip region covered an area of 20 km × 20 km. The seismic moment, calculated assuming a rigidity of 2.7 × 1010 N/m2 was 3.70 × 1019 Nm, equivalent to Mw = 7.0. This is slightly larger than the moments from the moment tensor solutions (Mw 6.9). Large secondary tsunami peaks arrived approximately an hour after clear initial peaks were recorded by the offshore pressure gauges and the Sendai and Ofunato tide gauges. Our tsunami propagation model suggests that the large secondary tsunami signals were from tsunami waves reflected off the Fukushima coast. A rather large tsunami amplitude of 75 cm at Kuji, about 300 km north of the source, was comparable to those recorded at stations located much closer to the epicenter, such as Soma and Onahama. Tsunami simulations and ray tracing for both real and artificial bathymetry indicate that a significant portion of the tsunami wave was refracted to the coast located around Kuji and Miyako due to bathymetry effects.
Park, Ji Hyun; Hwang, Gyu-Sam
2016-08-01
A blood pressure (BP) waveform contains various pieces of information related to respiratory variation. Systolic time interval (STI) reflects myocardial performance, and diastolic time interval (DTI) represents diastolic filling. This study examined whether respiratory variations of STI and DTI within radial arterial waveform are comparable to dynamic indices. During liver transplantation, digitally recorded BP waveform and stroke volume variation (SVV) were retrospectively analyzed. Beat-to-beat STI and DTI were extracted within each BP waveform, which were separated by dicrotic notch. Systolic time variation (STV) was calculated by the average of 3 consecutive respiratory cycles: [(STImax- STImin)/STImean]. Similar formula was used for diastolic time variation (DTV) and pulse pressure variation (PPV). Receiver operating characteristic analysis with area under the curve (AUC) was used to assess thresholds predictive of SVV ≥12% and PPV ≥12%. STV and DTV showed significant correlations with SVV (r= 0.78 and r= 0.67, respectively) and PPV (r= 0.69 and r= 0.69, respectively). Receiver operating characteristic curves demonstrated that STV ≥11% identified to predict SVV ≥12% with 85.7% sensitivity and 89.3% specificity (AUC = 0.935; P< .001). DTV ≥11% identified to predict SVV ≥12% with 71.4% sensitivity and 85.7% specificity (AUC = 0.829; P< .001). STV ≥12% and DTV ≥11% identified to predict PPV ≥12% with an AUC of 0.881 and 0.885, respectively. Respiratory variations of STI and DTI derived from radial arterial contour have a potential to predict hemodynamic response as a surrogate for SVV or PPV. Copyright © 2016 Elsevier Inc. All rights reserved.
Hasin, Tal; Huebner, Marianne; Li, Zhuo; Brown, Daniel; Stulak, John M; Boilson, Barry A; Joyce, Lyle; Pereira, Naveen L; Kushwaha, Sudhir S; Park, Soon J
2014-01-01
Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP < 60, 60-70, 70-80, 80-90, and ≥90), the correlation of CO with LVAD flow differed (R = 0.42, 0.67, 0.48, 0.32, 0.32, respectively). Indicating better correlation when mean blood pressure is 60 to 70 mm Hg. Left ventricular assist device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.
Yamane, Tsuyoshi; Fujii, Yoko; Orito, Kensuke; Osamura, Kaori; Kanai, Takao; Wakao, Yoshito
2008-12-01
To compare the effects of candesartan cilexetil and enalapril maleate on right ventricular myocardial remodeling in dogs with experimentally induced pulmonary stenosis. 24 Beagles. 18 dogs underwent pulmonary arterial banding (PAB) to induce right ventricular pressure overload, and 6 healthy dogs underwent sham operations (thoracotomy only [sham-operated group]). Dogs that underwent PAB were allocated to receive 1 of 3 treatments (6 dogs/group): candesartan (1 mg/kg, PO, q 24 h [PABC group]), enalapril (0.5 mg/kg, PO, q 24 h [PABE group]), or no treatment (PABNT group). Administration of treatments was commenced the day prior to surgery; control dogs received no cardiac medications. Sixty days after surgery, right ventricular wall thickness was assessed echocardiographically and plasma renin activity, angiotensin-converting enzyme activity, and angiotensin I and II concentrations were assessed; all dogs were euthanatized, and collagenous fiber area, cardiomyocyte diameter, and tissue angiotensin-converting enzyme and chymase-like activities in the right ventricle were evaluated. After 60 days of treatment, right ventricular wall thickness, cardiomyocyte diameter, and collagenous fiber area in the PABNT and PABE groups were significantly increased, compared with values in the PABC and sham-operated groups. Chymase-like activity was markedly greater in the PABE group than in other groups. Results indicated that treatment with candesartan but not enalapril effectively prevented myocardial remodeling in dogs with experimentally induced subacute right ventricular pressure overload.
Kingma, J G; Linderoth, B; Ardell, J L; Armour, J A; DeJongste, M J; Foreman, R D
2001-08-13
Electrical stimulation of the dorsal aspect of the upper thoracic spinal cord is used increasingly to treat patients with angina pectoris refractory to conventional therapeutic strategies. The purpose of this study was to determine whether spinal cord stimulation (SCS) in dogs affects regional myocardial blood flow and left-ventricular (LV) function before and during transient obstruction of the left anterior descending coronary artery (LAD). In anesthetized dogs, regional myocardial blood flow distribution was determined using radiolabeled microspheres and left-ventricular function was measured by impedance-derived pressure-volume loops. SCS was accomplished by stimulating the dorsal T1-T2 segments of the spinal cord using epidural bipolar electrodes at 90% of motor threshold (MT) (50 Hz, 0.2-ms duration). Effects of 5-min SCS were assessed under basal conditions and during 4-min occlusion of the LAD. SCS alone evoked no change in regional myocardial blood flow or cardiovascular indices. Transient LAD occlusion significantly diminished blood flow within ischemic, but not in non-ischemic myocardial tissue. Left ventricular pressure-volume loops were shifted rightward during LAD occlusion. Cardiac indices were altered similarly during LAD occlusion and concurrent SCS. SCS does not influence the distribution of blood flow within the non-ischemic or ischemic myocardium. Nor does it modify LV pressure-volume dynamics in the anesthetized experimental preparation.
Radial artery pulse waveform analysis based on curve fitting using discrete Fourier series.
Jiang, Zhixing; Zhang, David; Lu, Guangming
2018-04-19
Radial artery pulse diagnosis has been playing an important role in traditional Chinese medicine (TCM). For its non-invasion and convenience, the pulse diagnosis has great significance in diseases analysis of modern medicine. The practitioners sense the pulse waveforms in patients' wrist to make diagnoses based on their non-objective personal experience. With the researches of pulse acquisition platforms and computerized analysis methods, the objective study on pulse diagnosis can help the TCM to keep up with the development of modern medicine. In this paper, we propose a new method to extract feature from pulse waveform based on discrete Fourier series (DFS). It regards the waveform as one kind of signal that consists of a series of sub-components represented by sine and cosine (SC) signals with different frequencies and amplitudes. After the pulse signals are collected and preprocessed, we fit the average waveform for each sample using discrete Fourier series by least squares. The feature vector is comprised by the coefficients of discrete Fourier series function. Compared with the fitting method using Gaussian mixture function, the fitting errors of proposed method are smaller, which indicate that our method can represent the original signal better. The classification performance of proposed feature is superior to the other features extracted from waveform, liking auto-regression model and Gaussian mixture model. The coefficients of optimized DFS function, who is used to fit the arterial pressure waveforms, can obtain better performance in modeling the waveforms and holds more potential information for distinguishing different psychological states. Copyright © 2018 Elsevier B.V. All rights reserved.
Ayaz, Teslime; Kocaman, Sinan Altan; Durakoğlugil, Tuğba; Erdoğan, Turan; Şahin, Osman Zikrullah; Şahin, Serap Baydur; Çiçek, Yüksel; Şatiroğlu, Ömer
2014-01-01
Background and Objectives Left ventricular hypertrophy (LVH), a sign of subclinical cardiovascular disease, is an important predictor of cardiovascular morbidity and mortality. The aim of our study was to determine the association of left ventricular mass (LVM) with possible causative anthropometric and biochemical parameters as well as carotid intima-media thickness (CIMT) and brachial flow-mediated dilation (FMD) as surrogates of atherosclerosis and endothelial dysfunction, respectively, in previously untreated hypertensive patients. Subjects and Methods Our study included 114 consecutive previously untreated hypertensive patients who underwent echocardiography and ultrasonography to evaluate their vascular status and function via brachial artery CIMT and FMD. Results Among all study parameters, age, systolic blood pressure (BP), diastolic BP, pulse pressure, plasma glucose, uric acid, total bilirubin, direct bilirubin, hemoglobin, and CIMT were positively correlated with the LVM index. Multiple logistic regression analysis revealed that office systolic BP, age, male gender, and total bilirubin were independent predictors of LVH. Conclusion Bilirubin seems to be related to LVM and LVH. The positive association of bilirubin with these parameters is novel and requires further research. PMID:25278987
Flow characteristics around a deformable stenosis under pulsatile flow condition
NASA Astrophysics Data System (ADS)
Choi, Woorak; Park, Jun Hong; Byeon, Hyeokjun; Lee, Sang Joon
2018-01-01
A specific portion of a vulnerable stenosis is deformed periodically under a pulsatile blood flow condition. Detailed analysis of such deformable stenosis is important because stenotic deformation can increase the likelihood of rupture, which may lead to sudden cardiac death or stroke. Various diagnostic indices have been developed for a nondeformable stenosis by using flow characteristics and resultant pressure drop across the stenosis. However, the effects of the stenotic deformation on the flow characteristics remain poorly understood. In this study, the flows around a deformable stenosis model and two different rigid stenosis models were investigated under a pulsatile flow condition. Particle image velocimetry was employed to measure flow structures around the three stenosis models. The deformable stenosis model was deformed to achieve high geometrical slope and height when the flow rate was increased. The deformation of the stenotic shape enhanced jet deflection toward the opposite vessel wall of the stenosis. The jet deflection in the deformable model increased the rate of jet velocity and turbulent kinetic energy (TKE) production as compared with those in the rigid models. The effect of stenotic deformation on the pulsating waveform related with the pressure drop was analyzed using the TKE production rate. The deformable stenosis model exhibited a phase delay of the peak point in the waveform. These results revealed the potential use of pressure drop waveform as a diagnostic index for deformable stenosis.
Blood Pressure Monitoring for the Anesthesiologist: A Practical Review.
Bartels, Karsten; Esper, Stephen A; Thiele, Robert H
2016-06-01
Periodic, quantitative measurement of blood pressure (BP) in humans, predating the era of evidence-based medicine by over a century, is a component of the American Society of Anesthesiologists standards for basic anesthetic monitoring and is a staple of anesthetic management worldwide. Adherence to traditional BP parameters complicates the ability of investigators to determine whether particular BP ranges confer any clinical benefits. The BP waveform is a complex amalgamation of both antegrade and retrograde (reflected) pressure waves and is affected by vascular compliance, distance from the left ventricle, and the 3D structure of the vascular tree. Although oscillometry is the standard method of measuring BP semicontinuously in anesthetized patients and is the primary form of measurement in >80% of general anesthetics, major shortcomings of oscillometry are its poor performance at the extremes and its lack of information concerning BP waveform. Although arterial catheterization remains the gold standard for accurate BP measurement, 2 classes of devices have been developed to noninvasively measure the BP waveform continuously, including tonometric and volume clamp devices. Described in terms of a feedback loop, control of BP requires measurement, an algorithm (usually human), and an intervention. This narrative review article discusses the details of BP measurement and the advantages and disadvantages of both noninvasive and invasive monitoring, as well as the principles and algorithms associated with each technique.
New micro waveforms firstly recorded on electrocardiogram in human.
Liu, Renguang; Chang, Qinghua; Chen, Juan
2015-10-01
In our study, not only the P-QRS-T waves but also the micro-wavelets before QRS complex (in P wave and PR segment) and after QRS complex (ST segment and upstroke of T wave) were first to be identified on surface electrocardiogram in human by the "new electrocardiogram" machine (model PHS-A10) according to conventional 12-lead electrocardiogram connection methods. By comparison to the conventional electrocardiogram in 100 cases of healthy individuals and several patients with arrhythmias, we have found that the wavelets before P wave theoretically reflected electrical activity of sinus node and the micro-wavelets before QRS complex may be related to atrioventricular conduction system (atrioventricular node, His bundle and bundle branch) potentials. Noninvasive atrioventricular node and His bundle potential tracing will contribute to differentiation of the origin of wide QRS and the location of the atrioventricular block. We also have found that the wavelets after QRS complex may be associated with phase 2 and 3 repolarization of ventricular action potential, which will further reveal ventricular repolarization changes. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ntalianis, Argyrios; Kapelios, Chris J; Kanakakis, John; Repasos, Evangelos; Pantsios, Christos; Nana, Emmeleia; Kontogiannis, Christos; Malliaras, Konstantinos; Tsamatsoulis, Michael; Kaldara, Elisabeth; Charitos, Christos; Nanas, John N
2015-08-01
Right ventricular dysfunction is associated with high morbidity and mortality in candidates for left ventricular assist device (LVAD) implantation or cardiac transplantation. We examined the effects of prolonged intra-aortic balloon pump (IABP) support on right ventricular, renal and hepatic functions in patients presenting with end-stage heart failure. Between March 2008 and June 2013, fifteen patients (mean age = 49.5 years; 14 men) with end-stage systolic heart failure (HF), contraindications for any life saving procedure (conventional cardiac surgery, heart transplantation, LVAD implantation) and right ventricular dysfunction were supported with the IABP. The patients remained on IABP support for a mean of 73 ± 50 days (median 72, range of 13-155). We measured the echocardiographic and hemodynamic changes in right ventricular function, and the changes in serum creatinine and bilirubin concentrations before and during IABP support. Mean right atrial pressure decreased from 12.7 ± 6.5 to 3.8 ± 3.3 (P < 0.001) and pulmonary artery pressure decreased from 35.7 ± 10.6 to 25 ± 8.4 mmHg (P = 0.001), while cardiac index increased from 1.5 ± 0.4 to 2.2 ± 0.7 l/m(2)/min (P = 0.003) and right ventricular stroke work index from 485 ± 228 to 688 ± 237 mmHg × ml/m(2) (P = 0.043). Right ventricular end-diastolic diameter decreased from 34.0 ± 6.5 mm to 27.8 ± 6.2 mm (P < 0.001) and tricuspid annular systolic tissue Doppler velocity increased from 9.6 ± 2.4 cm/s to 11.1 ± 2.3 cm/s (P = 0.029). Serum creatinine and bilirubin decreased from 2.1 ± 1.3 to 1.4 ± 0.6 mg/dl and 2.0 ± 1.0 to 0.9 ± 0.5 mg/dl, respectively (P = 0.002 and P < 0.001, respectively). Prolonged IABP support of patients presenting with end-stage heart failure and right ventricular dysfunction induced significant improvement in right ventricular and peripheral organ function. Copyright © 2015. Published by Elsevier Ireland Ltd.
Jouan, Jérôme; Achouh, Paul; Besson, Laila; Carpentier, Alain; Fabiani, Jean-Noël
2012-09-01
Tricuspid valve surgery in the presence of severe right ventricular dysfunction and pulmonary hypertension secondary to mitral valve stenosis is associated with poor early outcomes. We report the case of a young patient, presenting with severe chronic mitral-tricuspid disease responsible for long-lasting pulmonary hypertension and altered right ventricular function, who initially underwent mitral valve replacement and 7 days later the correction of her tricuspid insufficiency. This 2-staged approach permitted progressive reduction of pulmonary pressure and partial right ventricular remodeling before closing the systolic release valve of the right ventricle represented by tricuspid regurgitation. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Non-dimensional physics of pulsatile cardiovascular networks and energy efficiency.
Yigit, Berk; Pekkan, Kerem
2016-01-01
In Nature, there exist a variety of cardiovascular circulation networks in which the energetic ventricular load has both steady and pulsatile components. Steady load is related to the mean cardiac output (CO) and the haemodynamic resistance of the peripheral vascular system. On the other hand, the pulsatile load is determined by the simultaneous pressure and flow waveforms at the ventricular outlet, which in turn are governed through arterial wave dynamics (transmission) and pulse decay characteristics (windkessel effect). Both the steady and pulsatile contributions of the haemodynamic power load are critical for characterizing/comparing disease states and for predicting the performance of cardiovascular devices. However, haemodynamic performance parameters vary significantly from subject to subject because of body size, heart rate and subject-specific CO. Therefore, a 'normalized' energy dissipation index, as a function of the 'non-dimensional' physical parameters that govern the circulation networks, is needed for comparative/integrative biological studies and clinical decision-making. In this paper, a complete network-independent non-dimensional formulation that incorporates pulsatile flow regimes is developed. Mechanical design variables of cardiovascular flow systems are identified and the Buckingham Pi theorem is formally applied to obtain the corresponding non-dimensional scaling parameter sets. Two scaling approaches are considered to address both the lumped parameter networks and the distributed circulation components. The validity of these non-dimensional number sets is tested extensively through the existing empirical allometric scaling laws of circulation systems. Additional validation studies are performed using a parametric numerical arterial model that represents the transmission and windkessel characteristics, which are adjusted to represent different body sizes and non-dimensional haemodynamic states. Simulations demonstrate that the proposed non-dimensional indices are independent of body size for healthy conditions, but are sensitive to deviations caused by off-design disease states that alter the energetic load. Sensitivity simulations are used to identify the relationship between pulsatile power loss and non-dimensional characteristics, and optimal operational states are computed. © 2016 The Author(s).
Suárez, Carmen; Villar, José; Martel, Nieves; Extremera, Blas Gil; Suliman, Najaty; Campo, Carlos; Castellanos, Victoriano; Liébana, Antonio; Rodilla, Enrique; Nieto, Javier; Velasco, Olga; Ruilope, Luis M
2006-01-04
Left ventricular hypertrophy is an important predictor of cardiovascular risk and its detection contributes to risk stratification. However, echocardiography is not a routine procedure and electrocardiography (ECG) underestimates its prevalence. To evaluate the prevalence of echocardiographic left ventricular hypertrophy in low and medium risk non-treated hypertensive subjects, in order to find out the percentage of them who would be reclassified as high risk patients. Cross-sectional, multicenter study was performed in hospital located hypertension units. An echocardiogram was performed in 197 previously untreated hypertensive patients, > 18 years, classified as having low (61%) or medium (39%) risk, according to the OMS/ISH classification. The presence of left ventricular hypertrophy was considered if left ventricular mass index was > or = 134 or 110 g/m(2) in men and women, respectively (Devereux criteria). A logistic regression analysis was performed to identify factors associated to left ventricular hypertrophy. The prevalence of left ventricular hypertrophy was 23.9% (95% CI:17.9-29.9), 25.6% in men and 22.6% in women. In the low risk group its prevalence was 20.7% and in medium risk group 29.5%. Factors associated to left ventricular hypertrophy were: years since the diagnosis of hypertension, OR:1.1 (95% CI:1.003-1.227); systolic blood pressure, OR:1.08 (95% CI:1.029-1.138); diastolic blood pressure, OR:0.9 (95% CI:0.882-0.991); and family history of cardiovascular disease, OR:4.3 (95% CI:1.52-12.18). These findings underline the importance of performing an echocardiogram in low and high risk untreated hypertensive patients in which treatment would otherwise be delayed for even one year.
Ventricular efficiency in pregnant women with congenital heart disease.
Muneuchi, Jun; Yamasaki, Keiko; Watanabe, Mamie; Fukumitsu, Azusa; Kawakami, Takeshi; Nakahara, Hiromasa; Joo, Kunitaka
2018-06-15
Pregnant women with congenital heart disease (CHD) are at risk of cardiovascular events during pregnancy as well as postpartum. The aim of our study is to address the feasibility of echocardiography-derived ventricular-arterial coupling during pregnancy and postpartum among women with CHD. In 31 pregnant women with CHD, we performed serial echocardiography at the first and third trimesters, early and late postpartum. The indices of contractility (single-beat determined end-systolic elastance, Ees ab ) and afterload (effective arterial elastance, Ea) were approximated on the basis of the systemic blood pressure and systemic ventricular volume. The ratio of stroke work and pressure-volume area (SW/PVA) representing ventricular efficiency was also calculated. Age at the delivery was 28 (24-31) years. ZAHARA score was 0.75 (0.75-1.50). Gestational age and birth weight of newborns were 38 (37-39) weeks and 2.73 (2.42-2.92) kg, respectively. Heart rate, systemic ventricular end-diastolic volume and stroke volume significantly increased from the first trimester to the third trimester and reversed postpartum to the values of the first trimester. Ees ab and Ea significantly decreased from the first trimester to the third trimester (Ees ab ; 4.90 [2.86-7.14] vs 3.41 [2.53-4.61] mm Hg/ml, p = 0.0001, Ea; 2.83 [1.74-3.30] vs 2.18 [1.67-2.68] mm Hg/ml, p = 0.0012), and reversed early postpartum parallelly. Ejection fraction and SW/PVA remained unchanged throughout pregnancy and postpartum. Echocardiography-derived ventricular-arterial coupling is feasible to understand ventricular function in pregnant women with CHD. Copyright © 2018 Elsevier B.V. All rights reserved.
Harjola, Veli-Pekka; Mebazaa, Alexandre; Čelutkienė, Jelena; Bettex, Dominique; Bueno, Hector; Chioncel, Ovidiu; Crespo-Leiro, Maria G; Falk, Volkmar; Filippatos, Gerasimos; Gibbs, Simon; Leite-Moreira, Adelino; Lassus, Johan; Masip, Josep; Mueller, Christian; Mullens, Wilfried; Naeije, Robert; Nordegraaf, Anton Vonk; Parissis, John; Riley, Jillian P; Ristic, Arsen; Rosano, Giuseppe; Rudiger, Alain; Ruschitzka, Frank; Seferovic, Petar; Sztrymf, Benjamin; Vieillard-Baron, Antoine; Yilmaz, Mehmet Birhan; Konstantinides, Stavros
2016-03-01
Acute right ventricular (RV) failure is a complex clinical syndrome that results from many causes. Research efforts have disproportionately focused on the failing left ventricle, but recently the need has been recognized to achieve a more comprehensive understanding of RV anatomy, physiology, and pathophysiology, and of management approaches. Right ventricular mechanics and function are altered in the setting of either pressure overload or volume overload. Failure may also result from a primary reduction of myocardial contractility owing to ischaemia, cardiomyopathy, or arrhythmia. Dysfunction leads to impaired RV filling and increased right atrial pressures. As dysfunction progresses to overt RV failure, the RV chamber becomes more spherical and tricuspid regurgitation is aggravated, a cascade leading to increasing venous congestion. Ventricular interdependence results in impaired left ventricular filling, a decrease in left ventricular stroke volume, and ultimately low cardiac output and cardiogenic shock. Identification and treatment of the underlying cause of RV failure, such as acute pulmonary embolism, acute respiratory distress syndrome, acute decompensation of chronic pulmonary hypertension, RV infarction, or arrhythmia, is the primary management strategy. Judicious fluid management, use of inotropes and vasopressors, assist devices, and a strategy focusing on RV protection for mechanical ventilation if required all play a role in the clinical care of these patients. Future research should aim to address the remaining areas of uncertainty which result from the complexity of RV haemodynamics and lack of conclusive evidence regarding RV-specific treatment approaches. © 2016 The Authors European Journal of Heart Failure © 2016 European Society of Cardiology.
Sedentary Screen Time and Left Ventricular Structure and Function: the CARDIA Study
Gibbs, Bethany Barone; Reis, Jared P.; Schelbert, Erik B.; Craft, Lynette L.; Sidney, Steve; Lima, Joao; Lewis, Cora E.
2013-01-01
Sedentary screen time (watching TV or using a computer) predicts cardiovascular outcomes independently from moderate and vigorous physical activity and could impact left ventricular structure and function through the adverse consequences of sedentary behavior. Purpose To determine whether sedentary screen time is associated with measures of left ventricular structure and function. Methods The Coronary Artery Risk Development in Young Adults (CARDIA) Study measured screen time by questionnaire and left ventricular structure and function by echocardiography in 2,854 black and white participants, aged 43–55 years, in 2010–2011. Generalized linear models evaluated cross-sectional trends for echocardiography measures across higher categories of screen time and adjusting for demographics, smoking, alcohol, and physical activity. Further models adjusted for potential intermediate factors (blood pressure, antihypertensive medication use, diabetes, and body mass index (BMI). Results The relationship between screen time and left ventricular mass(LVM) differed in blacks vs. whites. Among whites, higher screen time was associated with larger LVM (P<0.001), after adjustment for height, demographics, and lifestyle variables. Associations between screen time and LVM persisted when adjusting for blood pressure, antihypertensive medication use, and diabetes (P=0.008) but not with additional adjustment for BMI (P=0.503). Similar relationships were observed for screen time with LVM indexed to height2.7, relative wall thickness, and mass-to-volume ratio. Screen time was not associated with left ventricular structure among blacks or left ventricular function in either race group. Conclusions Sedentary screen time is associated with greater LVM in white adults and this relationship was largely explained by higher overall adiposity. The lack of association in blacks supports a potential qualitative difference in the cardiovascular consequences of sedentary screen-based behavior. PMID:23863618
Rehman, Michaela B; Garcia, Rodrigue; Christiaens, Luc; Larrieu-Ardilouze, Elisa; Howard, Luke S; Nihoyannopoulos, Petros
2018-04-15
Right ventricular function is the major determinant of morbidity and mortality in pulmonary arterial hypertension (PAH). The ESC risk assessment strategy for PAH is based on clinical status, exercise testing, NTproBNP, imaging and haemodynamics but does not include right ventricular function. Our aims were to test the power of resting echocardiographic measurements to classify PAH patients according to ESC exercise testing risk stratification cut-offs and to determine if the classification power of echocardiographic parameters varied in chronic thrombo-embolic pulmonary hypertension (CTEPH). We prospectively and consecutively recruited 46 PAH patients and 42 CTEPH patients referred for cardio-pulmonary exercise testing and comprehensive transthoracic echocardiography. Exercise testing parameters analyzed were peak oxygen consumption, percentage of predicted maximal oxygen consumption and the slope of ventilation against carbon dioxide production. Receiver operator characteristic curves were used to determine the optimal diagnostic cut-off values of echocardiographic parameters for classifying the patients in intermediate or high risk category according to exercise testing. Measurements of right ventricular systolic function were the best for classifying in PAH (area under the curve 0.815 to 0.935). Measurements of right ventricular pressure overload (0.810 to 0.909) were optimal for classifying according to exercise testing in CTEPH. Measurements of left ventricular function were of no use in either group. Measurements of right ventricular systolic function can classify according to exercise testing risk stratification cut-offs in PAH. However, this is not the case in CTEPH where pressure overload, rather than right ventricular function seems to be linked to exercise performance. Copyright © 2018 Elsevier B.V. All rights reserved.
Masked hypertension and cardiac remodeling in middle-aged endurance athletes.
Trachsel, Lukas D; Carlen, Frederik; Brugger, Nicolas; Seiler, Christian; Wilhelm, Matthias
2015-06-01
Extensive endurance training and arterial hypertension are established risk factors for atrial fibrillation. We aimed to assess the proportion of masked hypertension in endurance athletes and the impact on cardiac remodeling, mechanics, and supraventricular tachycardias (SVT). Male participants of a 10-mile race were recruited and included if office blood pressure was normal (<140/90 mmHg). Athletes were stratified into a masked hypertension and normotension group by ambulatory blood pressure. Primary endpoint was diastolic function, expressed as peak early diastolic mitral annulus velocity (E'). Left ventricular global strain, left ventricular mass/volume ratio, left atrial volume index, signal-averaged P-wave duration (SAPWD), and SVT during 24-h Holter monitoring were recorded. From 108 runners recruited, 87 were included in the final analysis. Thirty-three (38%) had masked hypertension. The mean age was 42 ± 8 years. Groups did not differ with respect to age, body composition, cumulative training hours, and 10-mile race time. Athletes with masked hypertension had a lower E' and a higher left ventricular mass/volume ratio. Left ventricular global strain, left atrial volume index, SAPWD, and SVT showed no significant differences between the groups. In multiple linear regression analysis, masked hypertension was independently associated with E' (beta = -0.270, P = 0.004) and left ventricular mass/volume ratio (beta = 0.206, P = 0.049). Cumulative training hours was the only independent predictor for left atrial volume index (beta = 0.474, P < 0.001) and SAPWD (beta = 0.481, P < 0.001). In our study, a relevant proportion of middle-aged athletes had masked hypertension, associated with a lower diastolic function and a higher left ventricular mass/volume ratio, but unrelated to left ventricular systolic function, atrial remodeling, or SVT.
Pulse Waveform and Transcranial Doppler Analysis during Lower Body Negative Pressure
1993-04-01
26, 23]. The application of negative pressure to the body for scientific or medical purposes was first used in 1841 by Junod , who used it to create a...localized hyperemia [26]. Junod also suggested that it could be used prior to invasive surgical procedures, since the syncope it was able to produce
Relationship between shortening load, contractility, and myocardial energetics in intact dog.
Dell'Italia, L J; Evanochko, W T; Blackwell, G G; Pearce, D J; Pohost, G M
1993-06-01
A canine model was developed to estimate left ventricular wall stress, volumes, contractility, and high-energy phosphate metabolites without the need for major surgery. A percutaneously inserted catheter-tip manometer was used to record high-fidelity left ventricular pressure while gradient echo cinemagnetic resonance (cine-MR) imaging alternated with in vivo 31P-nuclear magnetic resonance (NMR) spectroscopy during pharmacological maneuvers to increase cardiac work. Left ventricular circumferential wall stress, volumes, maximum rate of pressure development (dP/dtmax), and the ratio of phosphocreatine (PCr) to gamma-ATP (PCr/gamma-ATP) were recorded sequentially during control 1, dobutamine infusion, control 2, angiotensin infusion, and control 3 in five anesthetized, closed-chest dogs. PCr/gamma-ATP did not change significantly during controls 1-3, angiotensin, and dobutamine infusion. Left ventricular peak positive dP/dt (+dP/dtmax) increased significantly during dobutamine (3,338 +/- 831 mmHg/s, P < 0.001) but was unchanged during angiotensin (1,818 +/- 317 mmHg/s) and controls 1-3 (1,915 +/- 434 vs. 1,808 +/- 478 vs. 1,859 +/- 414 mmHg/s). However, dobutamine decreased the total systolic stress integral (area under the wall stress-time relationship) and end-diastolic and end-systolic volumes, whereas angiotensin increased these parameters compared with control conditions. The unchanged PCr/gamma-ATP is in accord with the results from other open-chest surface coil 31P-NMR experiments in the normal heart. Our assessment of left ventricular functional parameters provides new information that complements these more invasive studies in which heart rate-pressure product was measured during increases in cardiac work.(ABSTRACT TRUNCATED AT 250 WORDS)
Prediabetes and Cardiovascular Parameters in Obese Children and Adolescents
Eklioğlu, Beray Selver; Atabek, Mehmet Emre; Akyürek, Nesibe; Alp, Hayrullah
2016-01-01
Objective: In this study, our aim was to determine cardiovascular risk and cardiac function in prediabetic obese children and adolescents. Methods: The study was conducted on 198 obese children and adolescents 6-18 years of age. Anthropometric measurements, blood pressure measurements, oral glucose tolerance test, lipid profile, and HbA1c levels of patients were assessed. Prediabetes was defined according to American Diabetes Association criteria. Left ventricular mass index (LVMi), carotid intima-media thickness (c-IMT), and tissue Doppler measurements records were used. Results: LVMi was found to be significantly higher in the prediabetes group (p=0.03). There were no statistically significant differences in right ventricular tissue Doppler measurements between the prediabetic and non-prediabetic groups. Left ventricular tissue Doppler measurements were significantly higher in the prediabetes group: LVEEM (left ventricular E/e ratio) (p=0.04); LVEM (left ventricular myocardial velocity cm/s) (p=0.035). LVMi was found to positively correlate with triglyceride level, diastolic blood pressure, waist circumference, body weight standard deviation score and to negatively correlate with high-density lipoprotein cholesterol (p=0.043, r=0.15; p=0.039, r=0.15; p=0.025, r=0.17; p=0.009, r=0.19; p=0.038, r=-0.15, respectively). LVEM was correlated with glucose (p=0.046, r=0.15) and LVEEM was correlated with systolic blood pressure (p=0.035, r=0.15). In linear regression analysis for clinical cardiovascular risk factors, fasting glucose level was the best predictor of LVEM. Conclusion: In this study, deterioration of cardiac function in prediabetic obese children and adolescents was shown. We recommend determining cardiovascular risk and cardiac dysfunction at early stages in prediabetic obese children and adolescents. PMID:26759114
Prediabetes and Cardiovascular Parameters in Obese Children and Adolescents.
Eklioğlu, Beray Selver; Atabek, Mehmet Emre; Akyürek, Nesibe; Alp, Hayrullah
2016-03-05
In this study, our aim was to determine cardiovascular risk and cardiac function in prediabetic obese children and adolescents. The study was conducted on 198 obese children and adolescents 6-18 years of age. Anthropometric measurements, blood pressure measurements, oral glucose tolerance test, lipid profile, and HbA1c levels of patients were assessed. Prediabetes was defined according to American Diabetes Association criteria. Left ventricular mass index (LVMi), carotid intima-media thickness (c-IMT), and tissue Doppler measurements records were used. LVMi was found to be significantly higher in the prediabetes group (p=0.03). There were no statistically significant differences in right ventricular tissue Doppler measurements between the prediabetic and non-prediabetic groups. Left ventricular tissue Doppler measurements were significantly higher in the prediabetes group: LVEEM (left ventricular E/e ratio) (p=0.04); LVEM (left ventricular myocardial velocity cm/s) (p=0.035). LVMi was found to positively correlate with triglyceride level, diastolic blood pressure, waist circumference, body weight standard deviation score and to negatively correlate with high-density lipoprotein cholesterol (p=0.043, r=0.15; p=0.039, r=0.15; p=0.025, r=0.17; p=0.009, r=0.19; p=0.038, r=-0.15, respectively). LVEM was correlated with glucose (p=0.046, r=0.15) and LVEEM was correlated with systolic blood pressure (p=0.035, r=0.15). In linear regression analysis for clinical cardiovascular risk factors, fasting glucose level was the best predictor of LVEM. In this study, deterioration of cardiac function in prediabetic obese children and adolescents was shown. We recommend determining cardiovascular risk and cardiac dysfunction at early stages in prediabetic obese children and adolescents.
Modified Ross procedure using a conduit with a synthetic valve.
Takabayashi, Shin; Kado, Hideaki; Shiokawa, Yuichi; Fukae, Kouji; Nakano, Toshihide
2004-12-01
In the Ross procedure, a homograft conduit is commonly used in place of an autotransplanted pulmonary valve. Homograft availability may be a problem and has resulted in a search for alternatives. We performed a modified Ross procedure for right ventricular outflow tract reconstruction with a synthetic valved conduit as an alternative to homograft. Our early results of valvular and right ventricular function were evaluated in patients who used a conduit with a synthetic valve. Subjects consisted of 11 patients, who ranged in age from 5 to 22 years (12.0+/-4.9), and whose body weight ranged from 15.1 to 52.5 (34.3+/-14.4) kg. Indications for surgery were aortic stenosis (n=3), aortic stenosis and regurgitation (n=4), and aortic regurgitation (n=4). Right ventricular outflow tract reconstruction was performed using a hand-fashioned valved conduit prepared by sewing a 0.1 mm thick polytetrafluoroethylene sheet onto the luminal cavity of the 20-28 mm conduit. A conduit made with polytetrafluoroethylene was used in 8 patients, and a Dacron graft was used in 3 patients. There was no in-hospital or late mortality and angiocardiography at discharge revealed that all artificial valves remained active. The mean right atrial pressure and right ventricular end-diastolic pressure were not statistically different from preoperative values. The latest echocardiography (mean interval, 12.6 months) revealed that a mean pressure gradient across the synthetic valve was 11.4+/-11.1 mmHg and none of the patients had moderate or severe regurgitation. We demonstrated that a modified Ross procedure for right ventricular outflow tract reconstruction using a conduit with an appropriate synthetic valve is particularly effective in older children.
Kutty, Shelby; Olson, Joan; Danford, Christopher J; Sandene, Erin K; Xie, Feng; Fletcher, Scott E; Erickson, Christopher C; Kugler, John D; Danford, David A; Porter, Thomas R
2012-06-01
We sought to evaluate the efficacy of ultrasound contrast (UC) and low mechanical index real-time perfusion (RTP) in the haemodynamic and anatomic assessment of repaired congenital heart disease (CHD) at rest and during supine bicycle stress echocardiography (BSE). Patients with CHD (n = 51, median age 21.5 years) were prospectively studied. All had compromised image quality, 20 (39%) had arrhythmias, and 10 (20%) had pacemakers. RTP was performed at rest and during BSE using Definity and Contrast Pulse Sequencing, with assessment of Doppler pressure gradients. Diagnoses included tetralogy of Fallot (n = 27), transposition of the great arteries (TGA) atrial switch (n = 10), TGA arterial switch (n = 2), aortic valve disease (n = 4), Fontan (n = 4), and Kawasaki disease (n = 4). UC with RTP improved endocardial border definition, with increased number of left ventricular (LV) and right ventricular (RV) segments visualized at rest (P < 0.0001) and during stress. LV ejection fraction (EF) and RV fractional area change (FAC) were measurable at rest and peak stress, RV FAC correlating closely with same-day magnetic resonance EFs (r = 0.72; P < 0.001). UC enhanced Doppler signals, enabling subpulmonary ventricular systolic pressure measurements at rest and stress. In six patients, marked elevations of subpulmonary ventricular systolic pressure were detected with UC during BSE, and quantifiable ventricular dysfunction. No adverse events occurred, other than transient low back pain in one patient. UC at rest and with supine BSE enables safe and comprehensive assessment of anatomy, haemodynamics, and biventricular functional and perfusion reserve in adolescents and young adults with surgically modified CHD.
Non invasive evaluation of cardiomechanics in patients undergoing MitrClip procedure
2013-01-01
Background In the last recent years a new percutaneous procedure, the MitraClip, has been validated for the treatment of mitral regurgitation. MitraClip procedure is a promising alternative for patients unsuitable for surgery as it reduces the risk of death related to surgery ensuring a similar result. Few data are present in literature about the variation of hemodynamic parameters and ventricular coupling after Mitraclip implantation. Methods Hemodynamic data of 18 patients enrolled for MitraClip procedure were retrospectively reviewed and analyzed. Echocardiographic measurements were obtained the day before the procedure (T0) and 21 ± 3 days after the procedure (T1), including evaluation of Ejection Fraction, mitral valve regurgitation severity and mechanism, forward Stroke Volume, left atrial volume, estimated systolic pulmonary pressure, non invasive echocardiographic estimation of single beat ventricular elastance (Es(sb)), arterial elastance (Ea) measured as systolic pressure • 0.9/ Stroke Volume, ventricular arterial coupling (Ea/Es(sb) ratio). Data were expressed as median and interquartile range. Measures obtained before and after the procedure were compared using Wilcoxon non parametric test for paired samples. Results Mitraclip procedure was effective in reducing regurgitation. We observed an amelioration of echocardiographic parameters with a reduction of estimated systolic pulmonary pressure (45 to 37,5 p = 0,0002) and left atrial volume (110 to 93 p = 0,0001). Despite a few cases decreasing in ejection fraction (37 to 35 p = 0,035), the maintained ventricular arterial coupling after the procedure (P = 0,67) was associated with an increasing in forward stroke volume (60,3 to 78 p = 0,05). Conclusion MitraClip is effective in reducing mitral valve regurgitation and determines an amelioration of hemodynamic parameters with preservation of ventricular arterial coupling. PMID:23642140
Haemodynamic and energetic properties of stunned myocardium in rabbit hearts.
Schipke, J. D.; Korbmacher, B.; Dorszewski, A.; Selcan, G.; Sunderdiek, U.; Arnold, G.
1996-01-01
OBJECTIVE--To amplify the description of myocardial stunning. DESIGN--Control versus 30 min after a 20 min no flow ischaemia. EXPERIMENTAL ANIMALS--15 isolated rabbit hearts perfused with erythrocyte suspension. MAIN OUTCOME MEASURES--Left ventricular systolic function in terms of aortic flow, peak systolic pressure (LVPmax), dP/dtmax, and the end systolic pressure-volume relation (ESPVR); early relaxation from dP/dtmin and rate of left ventricular pressure decay (tau). Passive properties: ventricular and myocardial stiffness. Coronary resistance from coronary blood flow and perfusion pressure. Total myocardial oxygen consumption (MVo2tot). Total mechanical energy via pressure-volume area (PVA). Contractile efficiency (Econ) and MVo2 of the unloaded contracting heart (MVo2unl). External mechanical efficiency (Eext) from stroke work and MVo2tot. RESULTS--Systolic variables in stunned myocardium were significantly decreased (mean (SD)): aortic flow: 38 (13) v 9 (11) ml/min; LVPmax: 112 (19) v 74 (18) mm Hg; dP/dtmax: 1475 (400) v 1075 (275) mm Hg/s. ESPVR was not significantly decreased, at 138 (73) v 125 (58) mm Hg/ml, but the volume axis intercept was shifted rightward: 0.30 (0.37) v 0.65 (0.25) ml. Likewise, early relaxation was impaired: dP/dtmin (-1275 (250) v -975 (250) mm Hg/s) and tau (37 (7) v 46 (10) ms). LVPed was significantly decreased at 19 (12) v 12 (7) mm Hg, and both the ventricular (end diastolic pressure-volume relation) and the myocardial stiffness (constant k) were increased by 75% and 31%, respectively. Coronary resistance increased non-significantly from 0.83 (0.31) to 1.04 (0.41) mm Hg/(ml/min/100 g). Decreases in PVA (570 (280) v 270 (200) mm Hg.ml/100 g), MVo2tot (40 (9) v 34 (8) microliters/beat/100 g), and MVo2unl (26 (9) v 22 (6) microliters/beat/100 g) did not reach significance, in contrast to significant decreases in Econ (31 (18) v 14 (7)%) and Eext (0.75 (0.29) v 0.18 (0.25) arbitrary units). CONCLUSIONS--Ventricular systolic function is decreased after brief episodes of ischaemia. The decrease in diastolic function probably amplifies the systolic deterioration during myocardial stunning. Passive diastolic properties are also changed, shown by increases in both ventricular and myocardial stiffness. The increase in coronary resistance indicates stunning at the vascular level which could limit oxygen supply. With maintained MVo2tot during stunning, external efficiency is decreased. Possible candidates for this metabolic stunning are inadequate excitation-contraction coupling and disturbed O2 utilisation by the contractile apparatus. Images PMID:8624873
Sun, Xiaodong; Fang, Dawei; Zhang, Dong; Ma, Qingyu
2013-05-01
Different from the theory of acoustic monopole spherical radiation, the acoustic dipole radiation based theory introduces the radiation pattern of Lorentz force induced dipole sources to describe the principle of magnetoacoustic tomography with magnetic induction (MAT-MI). Although two-dimensional (2D) simulations have been studied for cylindrical phantom models, layer effects of the dipole sources within the entire object along the z direction still need to be investigated to evaluate the performance of MAT-MI for different geometric specifications. The purpose of this work is further verifying the validity and generality of acoustic dipole radiation based theory for MAT-MI with two new models in different shapes, dimensions, and conductivities. Based on the theory of acoustic dipole radiation, the principles of MAT-MI were analyzed with derived analytic formulae. 2D and 3D numerical studies for two new models of aluminum foil and cooked egg were conducted to simulate acoustic pressures and corresponding waveforms, and 2D images of the scanned layers were reconstructed with the simplified back projection algorithm for the waveforms collected around the models. The spatial resolution for conductivity boundary differentiation was also analyzed with different foil thickness. For comparison, two experimental measurements were conducted for a cylindrical aluminum foil phantom and a shell-peeled cooked egg. The collected waveforms and the reconstructed images of the scanned layers were achieved to verify the validation of the acoustic dipole radiation based theory for MAT-MI. Despite the difference between the 2D and 3D simulated pressures, good consistence of the collected waveforms proves that wave clusters are generated by the abrupt pressure changes with bipolar vibration phases, representing the opposite polarities of the conductivity changes along the measurement direction. The configuration of the scanned layer can be reconstructed in terms of shape and size, and the conductivity boundaries are displayed in stripes with different contrast and bipolar intensities. Layer effects are demonstrated to have little influence on the collected waveforms and the reconstructed images of the scanned layers for the two new models. The experimental results have good agreements with numerical simulations, and the reconstructed 2D images provide conductivity configurations in the scanned layers of the aluminum foil and the egg models. It can be concluded that the acoustic pressure of MAT-MI is produced by the divergence of the induced Lorentz force, and the collected waveforms comprise wave clusters with bipolar vibration phases and different amplitudes, providing the information of conductivity boundaries in the scanned layer. With the simplified back projection algorithm for diffraction sources, collected waveforms can be used to reconstruct 2D conductivity contrast image and the conductivity configuration in the scanned layer can be obtained in terms of shape and size in stripes with the spatial resolution of the acoustic wavelength. The favorable results further verify the validity and generality of the acoustic dipole radiation based theory and suggest the feasibility of MAT-MI as an effective electrical impedance contrast imaging approach for medical imaging.
Krieger, J; Grucker, D; Sforza, E; Chambron, J; Kurtz, D
1991-10-01
The effects of treatment with nasal continuous positive airway pressure (CPAP) on left ventricular ejection fraction (LVEF) were assessed in 29 patients with obstructive sleep apnea (OSA) in a prospective study using multiple gated equilibrium radionuclide angiocardiography. All patients were evaluated before CPAP treatment was initiated and were reevaluated after one year (mean +/- SE, 415 +/- 6 days), of home treatment with nasal CPAP. The mean LVEF increased from 59 +/- 1 percent to 63 +/- 1 percent (p less than 0.005). The degree of improvement in LVEF was correlated with baseline LVEF (r = 0.54; p less than 0.003), meaning that the lower the baseline value, the greater the increase with treatment. The changes were not different when subgroups of medicated and unmedicated patients were considered separately. These results show that long-term nasal CPAP treatment results in improved left ventricular function in OSA.
Pulse oximeter as a sensor of fluid responsiveness: do we have our finger on the best solution?
Monnet, Xavier; Lamia, Bouchra; Teboul, Jean-Louis
2005-01-01
The pulse oximetry plethysmographic signal resembles the peripheral arterial pressure waveform, and the degree of respiratory variation in the pulse oximetry wave is close to the degree of respiratory arterial pulse pressure variation. Thus, it is tempting to speculate that pulse oximetry can be used to assess preload responsiveness in mechanically ventilated patients. In this commentary we briefly review the complex meaning of the pulse oximetry plethysmographic signal and highlight the advantages, limitations and pitfalls of the pulse oximetry method. Future studies including volume challenge must be performed to test whether the pulse oximetry waveform can really serve as a nonivasive tool for the guidance of fluid therapy in patients receiving mechanical ventilation in intensive care units and in operating rooms. PMID:16277729
Haggerty, Christopher M; Fynn-Thompson, Francis; McElhinney, Doff B; Valente, Anne Marie; Saikrishnan, Neelakantan; Del Nido, Pedro J; Yoganathan, Ajit P
2012-09-01
This study sought to evaluate the performance of microaxial ventricular assist devices for the purposes of supporting failing Fontan physiology by decreasing central venous pressure. Three Abiomed Impella pumps (Abiomed, Inc, Danvers, Mass) were evaluated in a mock circulatory system of the Fontan circuit. The local response of pressures and flows to pump function was assessed as a function of pump speed and pulmonary vascular resistance at a high baseline central venous pressure. For one device, subsequent modeling studies were conducted using a lumped parameter model of the single ventricle circuit. The left ventricular devices (Impella 2.5, 5.0) were shown to be suboptimal as single device solutions for cavopulmonary support. The small area of these devices relative to vessel diameter led to significant flow recirculation without an obstructive separator in place. Furthermore, downstream pressure augmentation adversely affected the pressure in the superior vena cava. The use of 2 devices would be mandatory for successful support. The right-sided device (Impella RP), whose outflow was positioned in the left pulmonary artery, demonstrated decreased flow recirculation and did not impede superior caval venous flow. Although static pressure is still required to drive flow through the opposite lung, numeric modeling demonstrated the potential for modest but significant improvements in lowering the central venous pressure (2-8 mm Hg). Left-sided microaxial pumps are not well suited for cavopulmonary support because of severe flow recirculation and the need for multiple devices. The right-ventricular Impella device provides improved performance by directing flow into the pulmonary artery, resulting in modest decreases in central venous pressure. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Development of an Inlet Pressure Sensor for Control in a Left Ventricular Assist Device
Fritz, Bryan; Cysyk, Joshua; Newswanger, Ray; Weiss, William; Rosenberg, Gerson
2010-01-01
A Tesla type continuous flow left ventricular assist device (VAD) has been designed by Penn State and Advanced Bionics, Inc. (ABI). When a continuous flow device is employed, care must be taken to limit low pressures in the ventricle that can produce an obstruction to the inlet cannula or trigger arrhythmias. Design of an inexpensive, semi-conductor strain gage inlet pressure sensor to detect suction has been completed. The research and design analysis included finite element modeling of the sensing region. Sensitivity, step-response, temperature dependence and hysteresis tests have been performed on prototype units. All sensors were able to withstand the maximum expected strain of 82 μin/in at 500 mmHg internal pressure. Average sensitivity was 0.52 ±0.24 μV/mmHg with 0.5 V excitation (n=5 units). Step response time for a 0 to 90 mmHg step change averaged 22 milliseconds. Hysteresis was measured by applying and holding 75mmHg internal pressure for 4 hours, followed by a zero pressure measurement, and ranged from -15 mmHg to 4.1 mmHg (n=3 units). Offset drift varied between 180 and -140 mmHg over a four week period. (n=2 units). Span temperature sensitivity ranged from 18 to -21 μV/°C (n=5 units). Gain temperature sensitivity ranged from -7.4 to 4.9 μV/°C (n=5 units). With the inherent drift, it is currently not possible to use the transducer to measure actual pressures, but it can easily be used to measure pressure changes throughout the cardiac cycle. This signal can then be used in the control system to avoid ventricular suction events. PMID:20335797
Ohmori, S; Matsumura, K; Kajioka, T; Fukuhara, M; Abe, I; Fujishima, M
2000-07-01
The spectral power of heart rate variability has been shown to be negatively correlated with left ventricular mass (LVM), suggesting the contribution of left ventricular hypertrophy to autonomic dysfunction in essential hypertension. However, a simultaneous assessment of autonomic function and ambulatory blood pressure in relation to LVM has not been carried out. The objective of the present study was to elucidate the synergistic effects of ambulatory blood pressure and autonomic nerve activity on the heart. We enrolled 25 ambulant patients with untreated essential hypertension (9 men and 16 women; mean age 50.6 +/- 2.0 years). The ambulatory blood pressure and heart rate variability were simultaneously monitored every 30 min for 24 h. The spectral power of high-frequency (HF: 0.15 to 0.4 Hz) and low-frequency (LF: 0.05 to 0.15 Hz) bands were measured, and the ratio of LF to HF (LF/HF) was calculated. LF/HF and HF were used as indexes of sympathetic and parasympathetic activities, respectively. LVM was determined by echocardiography. Both the average daytime and nighttime systolic ambulatory blood pressures significantly correlated with the LVM index (r= 0.644, p< 0.001; and r= 0.428, p< 0.05; respectively), although there was no such correlation with the clinic blood pressures. In contrast, a single reading of ambulatory systolic blood pressure measured when LF/HF reached a maximum value was significantly correlated with the LVM index independently of age and sex (partial r= 0.484, p< 0.05). These results suggest that the ambulatory systolic blood pressure during increases in the activity of the sympathetic nervous system is able to infer LVM in essential hypertension.
Lehmkuhl, L B; Ware, W A; Bonagura, J D
1994-01-01
Mitral stenosis was diagnosed in 15 young to middle-aged dogs. There were 5 Newfoundlands and 4 bull terriers affected, suggesting a breed predisposition for this disorder. Clinical signs included cough, dyspnea, exercise intolerance, and syncope. Soft left apical diastolic murmurs were heard only in 4 dogs, whereas 8 dogs had systolic murmurs characteristic of mitral regurgitation. Left atrial enlargement was the most prominent radiographic feature. Left-sided congestive heart failure was detected by radiographs in 11 dogs within 1 year of diagnosis. Electrocardiographic abnormalities varied among dogs and included atrial and ventricular enlargement, as well as atrial and ventricular arrhythmias. Abnormalities on M-mode and two-dimensional echocardiograms included abnormal diastolic motion of the mitral valve characterized by decreased leaflet separation, valve doming, concordant motion of the parietal mitral valve leaflet, and a decreased E-to-F slope. Increased mitral valve inflow velocities and prolonged pressure half-times were detected by Doppler echocardiography. Cardiac catheterization, performed in 8 dogs, documented a diastolic pressure gradient between the left atrial, pulmonary capillary wedge, or pulmonary artery diastolic pressures and the left ventricular diastolic pressure. Necropsy showed mitral stenosis caused by thickened, fused mitral valve leaflets in 5 dogs and a supramitral ring in another dog. The outcome in affected dogs was poor; 9 of 15 dogs were euthanatized or died by 2 1/2 years of age.
Matsumoto, M; Hanrath, P; Kremer, P; Tams, C; Langenstein, B A; Schlüter, M; Weiter, R; Bleifeld, W
1982-01-01
In order to evaluate left ventricular function during dynamic exercise transoesophageal M-mode recordings of the left ventricle were carried out with a newly developed transducer gastroscope system. Twelve healthy subjects performed a graded supine bicycle exercise test. Stable and good quality images of the left ventricle at rest and during exercise at different steps up to a maximum workload of 100 watts were obtained in all patients. Isotonic maximum exercise resulted in a significant increase in fractional shortening of the left ventricle, peak shortening rate, and peak lengthening rate of the left ventricular minor axis. Left ventricular end-diastolic dimension decreased significantly. With increasing workload the pressure rate product increased significantly. It is concluded that transoesophageal M-mode echocardiography is a useful method of evaluating left ventricular performance during dynamic exercise. Images PMID:7082515
Schiller, Petter; Vikholm, Per; Hellgren, Laila
2016-03-01
Right ventricular (RV) failure is a major cause of morbidity and mortality after left ventricular assist device (LVAD) placement and remains hard to predict. We hypothesized that partial surgical exclusion of the RV with a modified Glenn shunt during LVAD treatment would reduce RV stroke work. An LVAD was implanted in eight pigs and a modified Glenn shunt was constructed. A conductance pressure-volume catheter was placed in the right ventricle through the apex. Haemodynamic data and pressure-volume loops were obtained at the following time periods: (i) baseline, (ii) open shunt, (iii) LVAD with closed shunt and (iii) LVAD and open shunt. During LVAD therapy, the right atrial (RA) pressure increased from 9 mmHg (9-9) to 15 mmHg (12-15), P = 0.01. RV stroke volume increased from 30 ml (29-40) to 51 ml (42-53), P < 0.01. Also, RV stroke work increased to 708 mmHg ml (654-1193) from 535 mmHg ml (424-717), P = 0.04, compared with baseline. During LVAD therapy in combination with a Glenn shunt, the RA pressure decreased from 15 mmHg (12-15) to 10 mmHg (7-11) when compared with LVAD therapy only, P = 0.01. A decrease in RV stroke work from 708 mmHg ml (654-1193) to 465 mmHg ml (366-711), P = 0.04, was seen when the LVAD was combined with a shunt, not significantly different from the baseline value (535 mmHg ml). The developed pressure in the right ventricle decreased from 29 mmHg (26-32) to 21 mmHg (20-24), P < 0.01. The pressure-volume loops of the RV show a significant reduction of RV stroke work during the use of the shunt with LVAD treatment. A modified Glenn shunt reduced RV volumes, RV stroke work and RA pressure during LVAD therapy in an experimental model of heart failure in pigs. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Tang, Wanchun; Weil, Max Harry; Jorgenson, Dawn; Klouche, Kada; Morgan, Carl; Yu, Ting; Sun, Shijie; Snyder, David
2002-12-01
For adults, 150-J fixed-energy, impedance-compensating biphasic truncated exponential (ICBTE) shocks are now effectively used in automated defibrillators. However, the high energy levels delivered by adult automated defibrillators preclude their use for pediatric patients. Accordingly, we investigated a method by which adult automated defibrillators may be adapted to deliver a 50-J ICBTE shock for pediatric defibrillation. Prospective, randomized study. A university-affiliated research institution. Domestic piglets. We initially investigated four groups of anesthetized mechanically ventilated piglets weighing 3.8, 7.5, 15, and 25 kg. Ventricular fibrillation was induced with an AC current delivered to the right ventricular endocardium. After 7 mins of untreated ventricular fibrillation, a conventional manual defibrillator was used to deliver up to three 50-J ICBTE shocks. If ventricular fibrillation was not reversed, a 1-min interval of precordial compression preceded a second sequence of up to three shocks. The protocol was repeated until spontaneous circulation was restored, or for a total of 15 mins. In a second set of experiments, we evaluated a 150-J biphasic adult automated defibrillator that was operated in conjunction with energy-reducing electrodes such as to deliver 50-J shocks. The same resuscitation protocol was then exercised on piglets weighing 3.7, 13.5, and 24.2 kg. All animals were successfully resuscitated. Postresuscitation hemodynamic and myocardial function quickly returned to baseline values in both experimental groups, and all animals survived. An adaptation of a 150-J biphasic adult automated defibrillator in which energy-reducing electrodes delivered 50-J shocks successfully resuscitated animals ranging from 3.7 to 25 kg without compromise of postresuscitation myocardial function or survival.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sohbatzadeh, Farshad, E-mail: f.sohbat@umz.ac.ir; Nano and Biotechnology Research Group, Faculty of Basic Sciences, University of Mazandaran, Babolsar 47416-95447, Mazandaran; Omran, Azadeh Valinataj
2014-11-15
In this work, we developed transporting atmospheric pressure cold plasma using single electrode configuration through a sub-millimetre flexible dielectric tube beyond 100 cm. It was shown that the waveform of the applied high voltage is essential for controlling upstream and downstream plasma inside the tube. In this regard, sawtooth waveform enabled the transport of plasma with less applied high voltage compared to sinusoidal and pulsed form voltages. A cold plasma string as long as 130 cm was obtained by only 4 kV peak-to-peak sawtooth high voltage waveform. Optical emission spectroscopy revealed that reactive chemical species, such as atomic oxygen and hydroxyl, are generatedmore » at the tube exit. The effect of tube diameter on the transported plasma was also examined: the smaller the diameter, the higher the applied voltage. The device is likely to be used for sterilization, decontamination, and therapeutic endoscopy as already suggested by other groups in recent past years.« less
Bruneau, B.; Diomede, P.; Economou, D. J.; ...
2016-06-08
Parallel plate capacitively coupled plasmas in hydrogen at relatively high pressure (~1 Torr) are excited with tailored voltage waveforms containing up to five frequencies. Predictions of a hybrid model combining a particle-in-cell simulation with Monte Carlo collisions and a fluid model are compared to phase resolved optical emission spectroscopy measurements, yielding information on the dynamics of the excitation rate in these discharges. When the discharge is excited with amplitude asymmetric waveforms, the discharge becomes electrically asymmetric, with different ion energies at each of the two electrodes. Unexpectedly, large differences in themore » $$\\text{H}_{2}^{+}$$ fluxes to each of the two electrodes are caused by the different $$\\text{H}_{3}^{+}$$ energies. When the discharge is excited with slope asymmetric waveforms, only weak electrical asymmetry of the discharge is observed. In this case, electron power absorption due to fast sheath expansion at one electrode is balanced by electron power absorption at the opposite electrode due to a strong electric field reversal.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fehler, M.; Bame, D.
1985-03-01
A study of the spectral properties of the waveforms recorded during hydraulic fracturing earthquakes has been carried out to obtain information about the physical dimensions of the earthquakes. We find two types of events. The first type has waveforms with clear P and S arrivals and spectra that are very similar to earthquakes occurring in tectonic regions. These events are interpreted as being due to shear slip along fault planes. The second type of event has waveforms that are similar in many ways to long period earthquakes observed at volcanoes and is called long period. Many waveforms of these eventsmore » are identical, which implies that these events represent repeated activation of a given source. We propose that the source of these long period events is the sudden opening of a channel that connects two cracks filled with fluid at different pressures. The sizes of the two cracks differ, which causes two or more peaks to appear in the spectra, each peak being associated with one physical dimension of the crack. From the frequencies at which spectral peaks occur, we estimate crack dimensions of between 3 and 22m. 13 refs., 8 figs.« less
Abramov, Dmitry; Haglund, Nicholas A; Di Salvo, Thomas G
2017-08-01
Although milrinone infusion is reported to benefit left ventricular function in chronic left heart failure, few insights exist regarding its effects on pulmonary circulation and right ventricular function. We retrospectively reviewed right heart catheterization data at baseline and during continuous infusion of milrinone in 69 patients with advanced heart failure and analyzed the effects on ventricular stroke work indices, pulmonary vascular resistance and pulmonary arterial compliance. Compared to baseline, milrinone infusion after a mean 58 ± 61 days improved mean left ventricular stroke work index (1540 ± 656 vs. 2079 ± 919 mmHg·mL/m 2 , p = 0.0007) to a much greater extent than right ventricular stroke work index (616 ± 346 vs. 654 ± 332, p = 0.053); however, patients with below median stroke work indices experienced a significant improvement in both left and right ventricular stroke work performance. Overall, milrinone reduced left and right ventricular filling pressures and pulmonary and systemic vascular resistance by approximately 20%. Despite an increase in pulmonary artery capacitance (2.3 ± 1.6 to 3.0 ± 2.0, p = 0.013) and a reduction in pulmonary vascular resistance (3.8 ± 2.3 to 3.0 ± 1.7 Wood units), milrinone did not reduce the transpulmonary gradient (13 ± 7 vs. 12 ± 6 mmHg, p = 0.252), the pulmonary artery pulse pressure (25 ± 10 vs. 24 ± 10, p = 0.64) or the pulmonary artery diastolic to pulmonary capillary wedge gradient (2.0 ± 6.5 vs. 2.4 ± 6.0, p = 0.353). Milrinone improved left ventricular stroke work indices to a greater extent than right ventricular stroke work indices and had beneficial effects on right ventricular net input impedance, predominantly via augmentation of left ventricular stroke volume and passive unloading of the pulmonary circuit. Patients who had the worst biventricular performance benefited the most from chronic milrinone infusion.
A Study of New Pulse Auscultation System
Chen, Ying-Yun; Chang, Rong-Seng
2015-01-01
This study presents a new type of pulse auscultation system, which uses a condenser microphone to measure pulse sound waves on the wrist, captures the microphone signal for filtering, amplifies the useful signal and outputs it to an oscilloscope in analog form for waveform display and storage and delivers it to a computer to perform a Fast Fourier Transform (FFT) and convert the pulse sound waveform into a heartbeat frequency. Furthermore, it also uses an audio signal amplifier to deliver the pulse sound by speaker. The study observed the principles of Traditional Chinese Medicine’s pulsing techniques, where pulse signals at places called “cun”, “guan” and “chi” of the left hand were measured during lifting (100 g), searching (125 g) and pressing (150 g) actions. Because the system collects the vibration sound caused by the pulse, the sensor itself is not affected by the applied pressure, unlike current pulse piezoelectric sensing instruments, therefore, under any kind of pulsing pressure, it displays pulse changes and waveforms with the same accuracy. We provide an acquired pulse and waveform signal suitable for Chinese Medicine practitioners’ objective pulse diagnosis, thus providing a scientific basis for this Traditional Chinese Medicine practice. This study also presents a novel circuit design using an active filtering method. An operational amplifier with its differential features eliminates the interference from external signals, including the instant high-frequency noise. In addition, the system has the advantages of simple circuitry, cheap cost and high precision. PMID:25875192
A study of new pulse auscultation system.
Chen, Ying-Yun; Chang, Rong-Seng
2015-04-14
This study presents a new type of pulse auscultation system, which uses a condenser microphone to measure pulse sound waves on the wrist, captures the microphone signal for filtering, amplifies the useful signal and outputs it to an oscilloscope in analog form for waveform display and storage and delivers it to a computer to perform a Fast Fourier Transform (FFT) and convert the pulse sound waveform into a heartbeat frequency. Furthermore, it also uses an audio signal amplifier to deliver the pulse sound by speaker. The study observed the principles of Traditional Chinese Medicine's pulsing techniques, where pulse signals at places called "cun", "guan" and "chi" of the left hand were measured during lifting (100 g), searching (125 g) and pressing (150 g) actions. Because the system collects the vibration sound caused by the pulse, the sensor itself is not affected by the applied pressure, unlike current pulse piezoelectric sensing instruments, therefore, under any kind of pulsing pressure, it displays pulse changes and waveforms with the same accuracy. We provide an acquired pulse and waveform signal suitable for Chinese Medicine practitioners' objective pulse diagnosis, thus providing a scientific basis for this Traditional Chinese Medicine practice. This study also presents a novel circuit design using an active filtering method. An operational amplifier with its differential features eliminates the interference from external signals, including the instant high-frequency noise. In addition, the system has the advantages of simple circuitry, cheap cost and high precision.
Mass spectrometric characterization of a high-field asymmetric waveform ion mobility spectrometer
NASA Astrophysics Data System (ADS)
Purves, Randy W.; Guevremont, Roger; Day, Stephen; Pipich, Charles W.; Matyjaszczyk, Matthew S.
1998-12-01
Ion mobility spectrometry (IMS) has become an important method for the detection of many compounds because of its high sensitivity and amenability to miniaturization for field-portable monitoring; applications include detection of narcotics, explosives, and chemical warfare agents. High-field asymmetric waveform ion mobility spectrometry (FAIMS) differs from IMS in that the electric fields are applied using a high-frequency periodic asymmetric waveform, rather than a dc voltage. Furthermore, in FAIMS the compounds are separated by the difference in the mobility of ions at high electric field relative to low field, rather than by compound to compound differences in mobility at low electric field (IMS). We report here the first cylindrical-geometry-FAIMS interface with mass spectrometry (FAIMS-MS) and the MS identification of the peaks observed in a FAIMS compensation voltage (CV) spectrum. Using both an electrometer-based-FAIMS (FAIMS-E) and FAIMS-MS, several variables that affect the sensitivity of ion detection were examined for two (polarity reversed) asymmetric waveforms (modes 1 and 2) each of which yields a unique spectrum. An increase in the dispersion voltage (DV) was found to improve the sensitivity and separation observed in the FAIMS CV spectrum. This increase in sensitivity and the unexpected dissimilarity in modes 1 and 2 suggest that atmospheric pressure ion focusing is occurring in the FAIMS analyzer. The sensitivity and peak locations in the CV spectra were affected by temperature, gas flow rates, operating pressure, and analyte concentration.
Endurance sport and "cardiac injury": a prospective study of recreational ironman athletes.
Leischik, Roman; Spelsberg, Norman
2014-09-03
Participation in triathlon competitions has increased in recent years. Many studies have described left or right ventricular injury in endurance athletes. The goal of this study was to examine the right and left ventricular cardiac structures and function and dynamic cardio-pulmonary performance in a large cohort of middle- and long-distance triathletes. 87 triathletes (54 male and 33 female) were examined using spiroergometry and echocardiography. The inclusion criterion was participation in at least one middle- or long distance triathlon. Male triathletes showed a maximum oxygen absorption of 58.1 ± 8.6 mL/min/kg (female triathletes 52.8 ± 5.7 mL/min/kg), maximum ergometer performance of 347.8 ± 49.9 W (female triathletes 264.5 ± 26.1 W). Left ventricular ejection fraction (EF) was normal (male triathletes EF: 61.9% ± 3%, female triathletes EF: 63.0% ± 2.7%) and systolic right ventricular area change fraction (RV AFC%) showed normal values (males RV AFC%: 33.5% ± 2.2%, females 32.2% ± 2.8%). Doppler indices of diastolic function were normal in both groups. With respect to the echocardiographic readings the left ventricular mass for males and females were 217.7 ± 41.6 g and 145.9 ± 31.3 g, respectively. The relative wall thickness for males was 0.50 ± 0.07, whereas it was 0.47 ± 0.09 for females. The probability of left ventricular mass >220 g increased with higher blood pressure during exercise (OR: 1.027, CI 1.002-1.052, p = 0.034) or with higher training volume (OR: 1.23, CI 1.04-1.47, p = 0.019). Right or left ventricular dysfunction could not be found, although the maximal participation in triathlon competitions was 29 years. A left ventricular mass >220 g is more likely to occur with higher arterial pressure during exercise and with a higher training volume.
Endurance Sport and “Cardiac Injury”: A Prospective Study of Recreational Ironman Athletes
Leischik, Roman; Spelsberg, Norman
2014-01-01
Background: Participation in triathlon competitions has increased in recent years. Many studies have described left or right ventricular injury in endurance athletes. The goal of this study was to examine the right and left ventricular cardiac structures and function and dynamic cardio-pulmonary performance in a large cohort of middle- and long-distance triathletes. Methods: 87 triathletes (54 male and 33 female) were examined using spiroergometry and echocardiography. The inclusion criterion was participation in at least one middle- or long distance triathlon. Results: Male triathletes showed a maximum oxygen absorption of 58.1 ± 8.6 mL/min/kg (female triathletes 52.8 ± 5.7 mL/min/kg), maximum ergometer performance of 347.8 ± 49.9 W (female triathletes 264.5 ± 26.1 W). Left ventricular ejection fraction (EF) was normal (male triathletes EF: 61.9% ± 3%, female triathletes EF: 63.0% ± 2.7%) and systolic right ventricular area change fraction (RV AFC%) showed normal values (males RV AFC%: 33.5% ± 2.2%, females 32.2% ± 2.8%). Doppler indices of diastolic function were normal in both groups. With respect to the echocardiographic readings the left ventricular mass for males and females were 217.7 ± 41.6 g and 145.9 ± 31.3 g, respectively. The relative wall thickness for males was 0.50 ± 0.07, whereas it was 0.47 ± 0.09 for females. The probability of left ventricular mass >220 g increased with higher blood pressure during exercise (OR: 1.027, CI 1.002–1.052, p = 0.034) or with higher training volume (OR: 1.23, CI 1.04–1.47, p = 0.019). Conclusions: Right or left ventricular dysfunction could not be found, although the maximal participation in triathlon competitions was 29 years. A left ventricular mass >220 g is more likely to occur with higher arterial pressure during exercise and with a higher training volume. PMID:25192145
Zito, Concetta; Mohammed, Moemen; Todaro, Maria Chiara; Khandheria, Bijoy K; Cusmà-Piccione, Maurizio; Oreto, Giuseppe; Pugliatti, Pietro; Abusalima, Mohamed; Antonini-Canterin, Francesco; Vriz, Olga; Carerj, Scipione
2014-11-01
We evaluated the interplay between left ventricular diastolic function and large-artery stiffness in asymptomatic patients at increased risk of heart failure and no structural heart disease (Stage A). We divided 127 consecutive patients (mean age 49 ± 17 years) with risk factors for heart failure who were referred to our laboratory to rule out structural heart disease into two groups according to presence (Group 1, n = 35) or absence (Group 2, n = 92) of grade I left ventricular diastolic dysfunction. Doppler imaging with high-resolution echo-tracking software was used to measure intima-media thickness (IMT) and stiffness of carotid arteries. Group 1 had significantly higher mean age, blood pressure, left ventricular mass index, carotid IMT and arterial stiffness than Group 2 (P < 0.05). Overall, carotid stiffness indices (β-stiffness index, augmentation index and elastic modulus) and 'one-point' pulse wave velocity each showed inverse correlation with E-wave velocity, E' velocity and E/A ratio, and direct correlation with A-wave velocity, E-wave deceleration time and E/E' ratio (P < 0.05). Arterial compliance showed negative correlations with the echocardiographic indices of left ventricular diastolic function (P < 0.05). On logistic regression analysis, age, hypertension, SBP, pulse pressure, left ventricular mass index, carotid IMT and stiffness parameters were associated with grade I left ventricular diastolic dysfunction (P < 0.05 for each). However, on multivariate logistic analysis, only 'one-point' pulse wave velocity and age were independent predictors (P = 0.038 and P = 0.016, respectively). An independent association between grade I left ventricular diastolic dysfunction and increased arterial stiffness is demonstrated at the earliest stage of heart failure. Hence, assessment of vascular function, beyond cardiac function, should be included in a comprehensive clinical evaluation of these patients.
MRimaging findings after ventricular puncture in patients with SAH.
Tominaga, J; Shimoda, M; Oda, S; Kumasaka, A; Yamazaki, K; Tsugane, R
2001-11-01
Using magnetic resonance (MR) imaging, we studied brain injury from ventricular puncture performed during craniotomy in the acute stage of subarachnoid hemorrhage (SAH). 80 patients underwent craniotomy for aneurysm obliteration within 48 hr after SAH, ventricular puncture for drainage of cerebrospinal fluid (CSF) was performed to reduce intracranial pressure. MR imaging was performed within 3 days following surgery to measure the size of the lesion, and was repeated on postoperative days 14 and 30. Of the 80 patients with ventricular puncture preceding craniotomy, 65 (81%) showed MR evidence of brain injury from the puncture. Overall, 149 lesions were detected. According to coronal images, cortical injuries (54 cases), penetrating injury to tracts along the ventricular tube (55 cases), caudate injury (25 cases), and corpus callosum injury (15 cases). Brain injuries from ventricular puncture did not correlate significantly to patient outcome. While ventricular puncture and drainage of CSF can readily be performed to decrease brain volume at the time of craniotomy in acute-stage SAH, neurosurgeons should be aware of a surprisingly high incidence of brain injury complicating puncture.
Measurement and numerical simulation of high intensity focused ultrasound field in water
NASA Astrophysics Data System (ADS)
Lee, Kang Il
2017-11-01
In the present study, the acoustic field of a high intensity focused ultrasound (HIFU) transducer in water was measured by using a commercially available needle hydrophone intended for HIFU use. To validate the results of hydrophone measurements, numerical simulations of HIFU fields were performed by integrating the axisymmetric Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation from the frequency-domain perspective with the help of a MATLAB-based software package developed for HIFU simulation. Quantitative values for the focal waveforms, the peak pressures, and the size of the focal spot were obtained in various regimes of linear, quasilinear, and nonlinear propagation up to the source pressure levels when the shock front was formed in the waveform. The numerical results with the HIFU simulator solving the KZK equation were compared with the experimental data and found to be in good agreement. This confirms that the numerical simulation based on the KZK equation is capable of capturing the nonlinear pressure field of therapeutic HIFU transducers well enough to make it suitable for HIFU treatment planning.
Computational Modeling of Meteor-Generated Ground Pressure Signatures
NASA Technical Reports Server (NTRS)
Nemec, Marian; Aftosmis, Michael J.; Brown, Peter G.
2017-01-01
We present a thorough validation of a computational approach to predict infrasonic signatures of centimeter-sized meteoroids. We assume that the energy deposition along the meteor trail is dominated by atmospheric drag and simulate the steady, inviscid flow of air in thermochemical equilibrium to compute the meteoroid's near-body pressure signature. This signature is then propagated through a stratified and windy atmosphere to the ground using a methodology adapted from aircraft sonic-boom analysis. An assessment of the numerical accuracy of the near field and the far field solver is presented. The results show that when the source of the signature is the cylindrical Mach-cone, the simulations closely match the observations. The prediction of the shock rise-time, the zero-peak amplitude of the waveform, and the duration of the positive pressure phase are consistently within 10% of the measurements. Uncertainty in the shape of the meteoroid results in a poorer prediction of the trailing part of the waveform. Overall, our results independently verify energy deposition estimates deduced from optical observations.
Pericardiectomy as a diagnostic and therapeutic procedure.
Konik, Ewa; Geske, Jeffrey; Edwards, William; Gersh, Bernard
2016-11-14
A 70-year-old man presented with recent onset, predominantly right-sided heart failure. Echocardiogram demonstrated features of hypertensive heart disease and was suggestive of, but non-diagnostic for, constrictive pericarditis (CP). CT demonstrated mild pericardial thickening. Right heart catheterisation showed elevation and equalisation of diastolic pressures in all cardiac chambers with early rapid filling, minimal ventricular interdependence, and no dissociation of intrathoracic and intracardiac pressures. While several features pointed towards CP, the minimal ventricular interdependence and no dissociation of intrathoracic and intracardiac pressures suggested other pathology. Diagnostic pericardiectomy was performed, after which the central venous pressure decreased from 22 to 12 mm Hg. Pathology revealed pericardial fibrosis. The patient experienced sustained resolution of his heart failure. A potential explanation for lack of CP criteria was the presence of hypertensive heart disease. CP needs to be considered when approaching patients with heart failure as diagnostic evaluation can be multifaceted and treatment curative. 2016 BMJ Publishing Group Ltd.
NASA Technical Reports Server (NTRS)
Tagawa, H.; Koide, M.; Sato, H.; Zile, M. R.; Carabello, B. A.; Cooper, G. 4th
1998-01-01
Increased microtubule density causes cardiocyte contractile dysfunction in right ventricular (RV) pressure-overload hypertrophy, and these linked phenotypic and contractile abnormalities persist and progress during the transition to failure. Although more severe in cells from failing than hypertrophied RVs, the mechanical defects are normalized in each case by microtubule depolymerization. To define the role of increased microtubule density in left ventricular (LV) pressure-overload hypertrophy and failure, in a given LV we examined ventricular mechanics, sarcomere mechanics, and free tubulin and microtubule levels in control dogs and in dogs with aortic stenosis both with LV hypertrophy alone and with initially compensated hypertrophy that had progressed to LV muscle failure. In comparing initial values with those at study 8 weeks later, dogs with hypertrophy alone had a very substantial increase in LV mass but preservation of a normal ejection fraction and mean systolic wall stress. Dogs with hypertrophy and associated failure had a substantial but lesser increase in LV mass and a reduction in ejection fraction, as well as a marked increase in mean systolic wall stress. Cardiocyte contractile function was equivalent, and unaffected by microtubule depolymerization, in cells from control LVs and those with compensated hypertrophy. In contrast, cardiocyte contractile function in cells from failing LVs was quite depressed but was normalized by microtubule depolymerization. Microtubules were increased only in failing LVs. These contractile and cytoskeletal changes, when assayed longitudinally in a given dog by biopsy, appeared in failing ventricles only when wall stress began to increase and function began to decrease. Thus, the microtubule-based cardiocyte contractile dysfunction characteristic of pressure-hypertrophied myocardium, originally described in the RV, obtains equally in the LV but is shown here to have a specific association with increased wall stress.
Imai, Yousuke; Kariya, Taro; Iwakiri, Masaki; Yamada, Yoshitsugu; Takimoto, Eiki
2018-01-01
Right ventricular (RV) dysfunction following left ventricular (LV) failure is associated with poor prognosis. RV remodeling is thought initiated by the increase in the afterload of RV due to secondary pulmonary hypertension (PH) to impaired LV function; however, RV molecular changes might occur in earlier stages of the disease. cGMP (cyclic guanosine monophosphate)-phosphodiesterase 5 (PDE5) inhibitors, widely used to treat PH through their pulmonary vasorelaxation properties, have shown direct cardiac benefits, but their impacts on the RV in LV diseases are not fully determined. Here we show that RV molecular alterations occur early in the absence of RV hemodynamic changes during LV pressure-overload and are ameliorated by PDE5 inhibition. Two-day moderate LV pressure-overload (transverse aortic constriction) neither altered RV pressure/ function nor RV weight in mice, while it induced only mild LV hypertrophy. Importantly, pathological molecular features were already induced in the RV free wall myocardium, including up-regulation of gene markers for hypertrophy and inflammation, and activation of extracellular signal-regulated kinase (ERK) and calcineurin. Concomitant PDE5 inhibition (sildenafil) prevented induction of such pathological genes and activation of ERK and calcineurin in the RV as well as in the LV. Importantly, dexamethasone also prevented these RV molecular changes, similarly to sildenafil treatment. These results suggest the contributory role of inflammation to the early pathological interventricular interaction between RV and LV. The current study provides the first evidence for the novel early molecular cross-talk between RV and LV, preceding RV hemodynamic changes in LV disease, and supports the therapeutic strategy of enhancing cGMP signaling pathway to treat heart diseases.
Brooks, Daina; Chandra, Akhil; Jaimes, Rafael; Sarvazyan, Narine; Kay, Matthew
2015-01-01
Biomonitoring studies have indicated that humans are routinely exposed to bisphenol A (BPA), a chemical that is commonly used in the production of polycarbonate plastics and epoxy resins. Epidemiological studies have shown that BPA exposure in humans is associated with cardiovascular disease; however, the direct effects of BPA on cardiac physiology are largely unknown. Previously, we have shown that BPA exposure slows atrioventricular electrical conduction, decreases epicardial conduction velocity, and prolongs action potential duration in excised rat hearts. In the present study, we tested if BPA exposure also adversely affects cardiac contractile performance. We examined the impact of BPA exposure level, sex, and pacing rate on cardiac contractile function in excised rat hearts. Hearts were retrogradely perfused at constant pressure and exposed to 10−9-10−4 M BPA. Left ventricular developed pressure and contractility were measured during sinus rhythm and during pacing (5, 6.5, and 9 Hz). Ca2+ transients were imaged from whole hearts and from neonatal rat cardiomyocyte layers. During sinus rhythm in female hearts, BPA exposure decreased left ventricular developed pressure and inotropy in a dose-dependent manner. The reduced contractile performance was exacerbated at higher pacing rates. BPA-induced effects on contractile performance were also observed in male hearts, albeit to a lesser extent. Exposure to BPA altered Ca2+ handling within whole hearts (reduced diastolic and systolic Ca2+ transient potentiation) and neonatal cardiomyocytes (reduced Ca2+ transient amplitude and prolonged Ca2+ transient release time). In conclusion, BPA exposure significantly impaired cardiac performance in a dose-dependent manner, having a major negative impact upon electrical conduction, intracellular Ca2+ handing, and ventricular contractility. PMID:25980024
Suzuki, Satoshi; Yoshihisa, Akiomi; Yamaki, Takayoshi; Sugimoto, Koichi; Kunii, Hiroyuki; Nakazato, Kazuhiko; Abe, Yukihiko; Saito, Tomiyoshi; Ohwada, Takayuki; Suzuki, Hitoshi; Saitoh, Shu-ichi; Kubota, Isao; Takeishi, Yasuchika
2015-01-01
Diuresis is a major therapy for the reduction of congestive symptoms in acute decompensated heart failure (ADHF) patients. Carperitide has natriuretic and vasodilatory effects, and tolvaptan produces water excretion without electrolyte excretion. We previously reported the usefulness of tolvaptan compared to carperitide in ADHF patients with fluid volume retention. The purpose of this study was to examine whether the efficacy of tolvaptan was altered in ADHF patients with reduced left ventricular systolic function and in those with hypotension. A total of 109 hospitalized ADHF patients were randomly assigned to either a tolvaptan or a carperitide treatment group. Baseline clinical characteristics were not different between the two groups. We divided these patients based on the left ventricular ejection fraction (EF) by echocardiography, and blood pressure (BP) at the time of admission. Daily urine volume between the tolvaptan and carperitide groups in patients with preserved EF (≥ 50%) was not different, however, in those with reduced EF (< 50%), the urine volume was significantly higher in the tolvaptan group than in the carperitide group (day 2, 3, 4, P < 0.05 for all). Daily urine volume did not differ between these two groups in the high blood pressure group (BP ≥ 140 mmHg), but was significantly higher in the tolvaptan group than in the carperitide group (day 1, P = 0.021; day 3, P = 0.017) in the low blood pressure group (BP < 140 mmHg). The present study reveals that tolvaptan is more effective than carperitide, especially in ADHF patients with reduced left ventricular systolic function and without hypertension.
Infrasound-induced hemodynamics, ultrastructure, and molecular changes in the rat myocardium.
Pei, Zhaohui; Sang, Hanfei; Li, Ruiman; Xiao, Pingxi; He, Jiangui; Zhuang, Zhiqiang; Zhu, Miaozhang; Chen, Jingzao; Ma, Hong
2007-04-01
Recent interest in adverse effects of infrasound on organisms arises from health concerns. We assessed the association between infrasound exposure of 5 Hz at 130 dB and changes of cardiac ultrastructure and function in rats. Thirty-two Sprague-Dawley rats were randomized into control, 1, 7, and 14 days groups for 2 h of infrasound once daily according to planned schedules. Changes of cardiac ultrastructure, hemodynamics indices, intracellular Ca(2+) concentrations ([Ca(2+)](i)), and sarcoplasmic reticulum Ca(2+)-ATPase 2 (SERCA2) were detected. Heart rates in 1 day group were significantly increased compared with control group and no significant changes in other groups. Left ventricular systolic pressures were significantly increased with time. Left ventricular diastolic end pressure and maximum rising rates of left ventricular pressure (+dl/dt) were significantly increased in 7 and 14 days groups and not changed in 1 day group, compared with control group. Maximum dropping rates of left ventricular pressure (-dl/dt) were significantly decreased in 7 and 14 days groups and not changed in 1 day group, compared with control group. In heart cells, there were several swelled mitochondria in 1 day group, more swelled mitochondria in 7 days group, platelet aggregation in the intercellular substance in 14 days group. [Ca(2+)](i) were significantly increased with time. There was a significant increase in SERCA2 in 1 day group, while a significant decrease in 7 and 14 days groups, compared with control group. Infrasound of 5 Hz at 130 dB can damage cardiac ultrastructure and function. Changes of [Ca(2+)](i) and SERCA2 play an important role in the secondary cardiac damage. (c) 2007 Wiley Periodicals, Inc.
Bouwmeester, J Christopher; Park, Jiheum; Valdovinos, John; Bonde, Pramod
2018-05-29
Changing the speed of left ventricular assist devices (LVADs) cyclically may be useful to restore aortic pulsatility; however, the effects of this pulsation on right ventricular (RV) function are unknown. This study investigates the effects of direct ventricular interaction by quantifying the amount of wave energy created by RV contraction when axial and centrifugal LVADs are used to assist the left ventricle. In 4 anesthetized pigs, pressure and flow were measured in the main pulmonary artery and wave intensity analysis was used to identify and quantify the energy of waves created by the RV. The axial pump depressed the intensity of waves created by RV contraction compared with the centrifugal pump. In both pump designs, there were only minor and variable differences between the continuous and pulsed operation on RV function. The axial pump causes the RV to contract with less energy compared with a centrifugal design. Diminishing the ability of the RV to produce less energy translates to less pressure and flow produced, which may lead to LVAD-induced RV failure. The effects of pulsed LVAD operation on the RV appear to be minimal during acute observation of healthy hearts. Further study is necessary to uncover the effects of other modes of speed modulation with healthy and unhealthy hearts to determine if pulsed operation will benefit patients by reducing LVAD complications.
Dynamic Energy Loss Characteristics in the Native Aortic Valve
NASA Astrophysics Data System (ADS)
Hwai Yap, Choon; Dasi, Laksmi P.; Yoganathan, Ajit P.
2009-11-01
Aortic Valve (AV) stenosis if untreated leads to heart failure. From a mechanics standpoint, heart failure implies failure to generate sufficient mechanical power to overcome energy losses in the circulation. Thus energy efficiency-based measures are direct measures of AV disease severity, which unfortunately is not used in current clinical measures of stenosis severity. We present an analysis of the dynamic rate of energy dissipation through the AV from direct high temporal resolution measurements of flow and pressure drop across the AV in a pulsatile left heart setup. Porcine AV was used and measurements at various conditions were acquired: varying stroke volumes; heart rates; and stenosis levels. Energy dissipation waveform has a distinctive pattern of being skewed towards late systole, attributed to the explosive growth of flow instabilities from adverse pressure gradient. Increasing heart rate and stroke volume increases energy dissipation, but does not alter the normalized shape of the dissipation temporal profile. Stenosis increases energy dissipation and also alters the normalized shape of dissipation waveform with significantly more losses during late acceleration phase. Since stenosis produces a departure from the signature dissipation waveform shape, dynamic energy dissipation analysis can be extended into a clinical tool for AV evaluation.
Improved Pulse Wave Velocity Estimation Using an Arterial Tube-Load Model
Gao, Mingwu; Zhang, Guanqun; Olivier, N. Bari; Mukkamala, Ramakrishna
2015-01-01
Pulse wave velocity (PWV) is the most important index of arterial stiffness. It is conventionally estimated by non-invasively measuring central and peripheral blood pressure (BP) and/or velocity (BV) waveforms and then detecting the foot-to-foot time delay between the waveforms wherein wave reflection is presumed absent. We developed techniques for improved estimation of PWV from the same waveforms. The techniques effectively estimate PWV from the entire waveforms, rather than just their feet, by mathematically eliminating the reflected wave via an arterial tube-load model. In this way, the techniques may be more robust to artifact while revealing the true PWV in absence of wave reflection. We applied the techniques to estimate aortic PWV from simultaneously and sequentially measured central and peripheral BP waveforms and simultaneously measured central BV and peripheral BP waveforms from 17 anesthetized animals during diverse interventions that perturbed BP widely. Since BP is the major acute determinant of aortic PWV, especially under anesthesia wherein vasomotor tone changes are minimal, we evaluated the techniques in terms of the ability of their PWV estimates to track the acute BP changes in each subject. Overall, the PWV estimates of the techniques tracked the BP changes better than those of the conventional technique (e.g., diastolic BP root-mean-squared-errors of 3.4 vs. 5.2 mmHg for the simultaneous BP waveforms and 7.0 vs. 12.2 mmHg for the BV and BP waveforms (p < 0.02)). With further testing, the arterial tube-load model-based PWV estimation techniques may afford more accurate arterial stiffness monitoring in hypertensive and other patients. PMID:24263016
Huang, Q-F; Sheng, C-S; Kang, Y-Y; Zhang, L; Wang, S; Li, F-K; Cheng, Y-B; Guo, Q-H; Li, Y; Wang, J-G
2016-07-01
We investigated the association of plasma AGE (advanced glycation end product) concentration with central and peripheral blood pressures and central-to-brachial blood pressure amplification in a Chinese population. The study subjects were from a newly established residential area in the suburb of Shanghai. Using the SphygmoCor system, we recorded radial arterial waveforms and derived aortic waveforms by a generalized transfer function and central systolic and pulse pressure by calibration for brachial blood pressure measured with an oscillometric device. The central-to-brachial pressure amplification was expressed as the central-to-brachial systolic blood pressure difference and pulse pressure difference and ratio. Plasma AGE concentration was measured by the enzyme-linked immunosorbent assay method and logarithmically transformed for statistical analysis. The 1051 participants (age, 55.1±13.1 years) included 663 women. After adjustment for sex, age and other confounding factors, plasma AGE concentration was associated with central but not peripheral blood pressures and with some of the pressure amplification indexes. Indeed, each 10-fold increase in plasma AGE concentration was associated with 2.94 mm Hg (P=0.04) higher central systolic blood pressure and 2.39% lower central-to-brachial pulse pressure ratio (P=0.03). In further subgroup analyses, the association was more prominent in the presence of hypercholesterolemia (+8.11 mm Hg, P=0.008) for central systolic blood pressure and in the presence of overweight and obesity (-4.89%, P=0.009), diabetes and prediabetes (-6.26%, P=0.10) or current smoking (-6.68%, P=0.045) for central-to-brachial pulse pressure ratio. In conclusion, plasma AGE concentration is independently associated with central systolic blood pressure and pulse pressure amplification, especially in the presence of several modifiable cardiovascular risk factors.
Primary angioplasty for infarction due to isolated right ventricular artery occlusion.
Chahal, Anwar A; Kim, Min-Young; Borg, Alexander N; Al-Najjar, Yahya
2014-11-26
We report an unusual case of an isolated right ventricular infarction with haemodynamic compromise caused by spontaneous isolated proximal occlusion of the right ventricular branch of the right coronary artery (RCA), successfully treated by balloon angioplasty. A 58-year-old gentleman presented with epigastric pain radiating into both arms. Electrocardiograph with right ventricular leads confirmed ST elevation in V4R and a diagnosis of isolated right ventricular infarction was made. Urgent primary percutaneous intervention was performed which revealed occlusion of the right ventricular branch of the RCA. During the procedure, the patient's blood pressure dropped to 80/40 mmHg, and echocardiography showed impaired right ventricular systolic function. Despite aggressive fluid resuscitation, the patient remained hypotensive, continued to have chest pain and persistent electrocardiograph changes, and hence balloon angioplasty was performed on the proximal right ventricular branch which restored flow to the vessel and revealed a severe ostial stenosis. This was treated with further balloon angioplasty which restored TIMI 3 flow with resolution of patient's symptoms. Repeat echocardiography showed complete resolution of the ST-elevation in leads V4R and V5R and partial resolution in V1. Subsequent dobutamine-stress echocardiography at 4 wk showed good left and right ventricular contractions. The patient was discharged after a 3-d in-patient stay without any complications.
2012-01-01
Background We recently reported that in an experimental setting the zero pressure level of solid intracranial pressure (ICP) sensors can be altered by electrostatics discharges. Changes in the zero pressure level would alter the ICP level (mean ICP); whether spontaneous changes in mean ICP happen in clinical settings is not known. This can be addressed by comparing the ICP parameters level and waveform of simultaneous ICP signals. To this end, we retrieved our recordings in patients with cerebral bleeds wherein the ICP had been recorded simultaneously from two different sensors. Materials and Methods: During a time period of 10 years, 17 patients with cerebral bleeds were monitored with two ICP sensors simultaneously; sensor 1 was always a solid sensor while Sensor 2 was a solid -, a fluid - or an air-pouch sensor. The simultaneous signals were analyzed with automatic identification of the cardiac induced ICP waves. The output was determined in consecutive 6-s time windows, both with regard to the static parameter mean ICP and the dynamic parameters (mean wave amplitude, MWA, and mean wave rise time, MWRT). Differences in mean ICP, MWA and MWRT between the two sensors were determined. Transfer functions between the sensors were determined to evaluate how sensors reproduce the ICP waveform. Results Comparing findings in two solid sensors disclosed major differences in mean ICP in 2 of 5 patients (40%), despite marginal differences in MWA, MWRT, and linear phase magnitude and phase. Qualitative assessment of trend plots of mean ICP and MWA revealed shifts and drifts of mean ICP in the clinical setting. The transfer function analysis comparing the solid sensor with either the fluid or air-pouch sensors revealed more variable transfer function magnitude and greater differences in the ICP waveform derived indices. Conclusions Simultaneous monitoring of ICP using two solid sensors may show marked differences in static ICP but close to identity in dynamic ICP waveforms. This indicates that shifts in ICP baseline pressure (sensor zero level) occur clinically; trend plots of the ICP parameters also confirm this. Solid sensors are superior to fluid – and air pouch sensors when evaluating the dynamic ICP parameters. PMID:22958653
Rahaghi, Farbod N; Vegas-Sanchez-Ferrero, Gonzalo; Minhas, Jasleen K; Come, Carolyn E; De La Bruere, Isaac; Wells, James M; González, Germán; Bhatt, Surya P; Fenster, Brett E; Diaz, Alejandro A; Kohli, Puja; Ross, James C; Lynch, David A; Dransfield, Mark T; Bowler, Russel P; Ledesma-Carbayo, Maria J; San José Estépar, Raúl; Washko, George R
2017-05-01
Imaging-based assessment of cardiovascular structure and function provides clinically relevant information in smokers. Non-cardiac-gated thoracic computed tomographic (CT) scanning is increasingly leveraged for clinical care and lung cancer screening. We sought to determine if more comprehensive measures of ventricular geometry could be obtained from CT using an atlas-based surface model of the heart. Subcohorts of 24 subjects with cardiac magnetic resonance imaging (MRI) and 262 subjects with echocardiography were identified from COPDGene, a longitudinal observational study of smokers. A surface model of the heart was manually initialized, and then automatically optimized to fit the epicardium for each CT. Estimates of right and left ventricular (RV and LV) volume and free-wall curvature were then calculated and compared to structural and functional metrics obtained from MRI and echocardiograms. CT measures of RV dimension and curvature correlated with similar measures obtained using MRI. RV and LV volume obtained from CT inversely correlated with echocardiogram-based estimates of RV systolic pressure using tricuspid regurgitation jet velocity and LV ejection fraction respectively. Patients with evidence of RV or LV dysfunction on echocardiogram had larger RV and LV dimensions on CT. Logistic regression models based on demographics and ventricular measures from CT had an area under the curve of >0.7 for the prediction of elevated right ventricular systolic pressure and ventricular failure. These data suggest that non-cardiac-gated, non-contrast-enhanced thoracic CT scanning may provide insight into cardiac structure and function in smokers. Copyright © 2017. Published by Elsevier Inc.
Ma, Jianying; Qian, Juying; Zeng, Xin; Sun, Aijun; Chang, Shufu; Chen, Zhangwei; Zou, Yunzeng
2012-01-01
Introduction Although coronary microembolization (CME) is a frequent phenomenon in patients undergoing percutaneous coronary intervention, few data are available on the changes in left ventricular ejection fraction (LVEF) and coronary flow reserve (CFR) after CME. Material and methods In this study, six miniature swine of either sex (body weight 21-25 kg) were used to prepare a CME model. After coronary angiography, 1.2 × 105 microspheres (42 µm) were selectively infused into the left anterior descending artery via an infusion catheter. Left ventricular ejection fraction was evaluated using transthoracic echocardiography; myocardial blood flow was measured using coloured microspheres; and CFR and coronary pressure were measured using Doppler and a pressure wire. Results Left ventricular ejection fraction was 0.77 ±0.08 at baseline, 0.69 ±0.08 at 2 h, 0.68 ±0.08 at 6 h, and 0.76 ±0.06 at 1 week (2 h vs. baseline p < 0.05; 6 h vs. baseline p < 0.01). After CME, left ventricular end systolic volume (LVESV) and end diastolic volume (LVEDV) were significant larger 1 week later (p < 0.01 for both), while CFR was significantly reduced at 6 h (1.24 ±0.10 at 6 h vs. 1.77 ±0.30 at baseline, p < 0.01) and myocardial blood flow remained unchanged. Serum ET-1 level was significantly higher only at 6 h after CME (6 h vs. baseline p < 0.05). Conclusions Reduction of CFR and LVEF is significant at 6 h after CME and recovers 1 week later with left ventricular dilation. PMID:22457677
Cardiac structure and function in relation to cardiovascular risk factors in Chinese
2012-01-01
Background Cardiac structure and function are well-studied in Western countries. However, epidemiological data is still scarce in China. Methods Our study was conducted in the framework of cardiovascular health examinations for the current and retired employees of a factory and their family members. According to the American Society of Echocardiography recommendations, we performed echocardiography to evaluate cardiac structure and function, including left atrial volume, left ventricular hypertrophy and diastolic dysfunction. Results The 843 participants (43.0 years) included 288 (34.2%) women, and 191 (22.7%) hypertensive patients, of whom 82 (42.9%) took antihypertensive drugs. The prevalence of left atrial enlargement, left ventricular hypertrophy and concentric remodeling was 2.4%, 5.0% and 12.7%, respectively. The prevalence of mild and moderate-to-severe left ventricular diastolic dysfunction was 14.2% and 3.3%, respectively. The prevalence of these cardiac abnormalities significantly (P ≤ 0.002) increased with age, except for the moderate-to-severe left ventricular diastolic dysfunction. After adjustment for age, gender, body height and body weight, left atrial enlargement was associated with plasma glucose (P = 0.009), and left ventricular hypertrophy and diastolic dysfunction were significantly associated with systolic and diastolic blood pressure (P ≤ 0.03), respectively. Conclusions The prevalence of cardiac structural and functional abnormalities increased with age in this Chinese population. Current drinking and plasma glucose had an impact on left atrial enlargement, whereas systolic and diastolic blood pressures were major correlates for left ventricular hypertrophy and diastolic dysfunction, respectively. PMID:23035836
Kobayashi, Kazuyoshi; Imagama, Shiro; Ito, Zenya; Ando, Kei; Hida, Tetsuro; Ito, Kenyu; Tsushima, Mikito; Ishikawa, Yoshimoto; Matsumoto, Akiyuki; Nishida, Yoshihiro; Ishiguro, Naoki
2017-01-01
OBJECTIVE Corrective surgery for spinal deformities can lead to neurological complications. Several reports have described spinal cord monitoring in surgery for spinal deformity, but only a few have included patients younger than 20 years with adolescent idiopathic scoliosis (AIS). The goal of this study was to evaluate the characteristics of cases with intraoperative transcranial motor evoked potential (Tc-MEP) waveform deterioration during posterior corrective fusion for AIS. METHODS A prospective database was reviewed, comprising 68 patients with AIS who were treated with posterior corrective fusion in a prospective database. A total of 864 muscles in the lower extremities were chosen for monitoring, and acceptable baseline responses were obtained from 819 muscles (95%). Intraoperative Tc-MEP waveform deterioration was defined as a decrease in intraoperative amplitude of ≥ 70% of the control waveform. Age, Cobb angle, flexibility, operative time, estimated blood loss (EBL), intraoperative body temperature, blood pressure, number of levels fused, and correction rate were examined in patients with and without waveform deterioration. RESULTS The patients (3 males and 65 females) had an average age of 14.4 years (range 11-19 years). The mean Cobb angles before and after surgery were 52.9° and 11.9°, respectively, giving a correction rate of 77.4%. Fourteen patients (20%) exhibited an intraoperative waveform change, and these occurred during incision (14%), after screw fixation (7%), during the rotation maneuver (64%), during placement of the second rod after the rotation maneuver (7%), and after intervertebral compression (7%). Most waveform changes recovered after decreased correction or rest. No patient had a motor deficit postoperatively. In multivariate analysis, EBL (OR 1.001, p = 0.085) and number of levels fused (OR 1.535, p = 0.045) were associated with waveform deterioration. CONCLUSIONS Waveform deterioration commonly occurred during rotation maneuvers and more frequently in patients with a larger preoperative Cobb angle. The significant relationships of EBL and number of levels fused with waveform deterioration suggest that these surgical invasions may be involved in waveform deterioration.
Wigle, E D; Auger, P; Marquis, Y
1966-10-15
Two types of intraventricular pressure differences within the left ventricle of man are described. The first is encountered in cases of muscular (or fibrous) subaortic stenosis, in which the outflow tract pressure distal to the stenosis (and proximal to the aortic valve) is low, whereas all pressures recorded in the left ventricle proximal to the stenosis, including that just inside the mitral valve (the initial inflow tract pressure) are high.The second type of intraventricular pressure difference may be recorded in patients without muscular subaortic stenosis when a heart catheter is advanced to the left ventricular wall in such a manner that it becomes imbedded or entrapped by cardiac muscle in systole. Such an entrapped catheter records a high intraventricular pressure that is believed to reflect intramyocardial tissue pressure, which normally exceeds intracavitary pressure. In such cases the initial inflow tract pressure is not high and is precisely equal to the outflow tract systolic pressure, i.e. both are recording intracavity pressure. This type of intramyocardial to intracavitary pressure difference may also be encountered in the left ventricle of dogs.The recent suggestion that intraventricular pressure differences in the left ventricle of cases of muscular subaortic stenosis are due to catheter entrapment by cardiac muscle is refuted by using the initial inflow tract pressure as the means of differentiation between the two types of intraventricular pressure differences outlined.
2010-01-01
Introduction We developed a minimally invasive, closed chest pig model with the main aim to describe hemodynamic function during surface cooling, steady state severe hypothermia (one hour at 25°C) and surface rewarming. Methods Twelve anesthetized juvenile pigs were acutely catheterized for measurement of left ventricular (LV) pressure-volume loops (conductance catheter), cardiac output (Swan-Ganz), and for vena cava inferior occlusion. Eight animals were surface cooled to 25°C, while four animals were kept as normothermic time-matched controls. Results During progressive cooling and steady state severe hypothermia (25°C) cardiac output (CO), stroke volume (SV), mean arterial pressure (MAP), maximal deceleration of pressure in the cardiac cycle (dP/dtmin), indexes of LV contractility (preload recruitable stroke work, PRSW, and maximal acceleration of pressure in the cardiac cycle, dP/dtmax) and LV end diastolic and systolic volumes (EDV and ESV) were significantly reduced. Systemic vascular resistance (SVR), isovolumetric relaxation time (Tau), and oxygen content in arterial and mixed venous blood increased significantly. LV end diastolic pressure (EDP) remained constant. After rewarming all the above mentioned hemodynamic variables that were depressed during 25°C remained reduced, except for CO that returned to pre-hypothermic values due to an increase in heart rate. Likewise, SVR and EDP were significantly reduced after rewarming, while Tau, EDV, ESV and blood oxygen content normalized. Serum levels of cardiac troponin T (TnT) and tumor necrosis factor-alpha (TNF-α) were significantly increased. Conclusions Progressive cooling to 25°C followed by rewarming resulted in a reduced systolic, but not diastolic left ventricular function. The post-hypothermic increase in heart rate and the reduced systemic vascular resistance are interpreted as adaptive measures by the organism to compensate for a hypothermia-induced mild left ventricular cardiac failure. A post-hypothermic increase in TnT indicates that hypothermia/rewarming may cause degradation of cardiac tissue. There were no signs of inadequate global oxygenation throughout the experiments. PMID:21092272
Ishihara, Shiro; Gayat, Etienne; Sato, Naoki; Arrigo, Mattia; Laribi, Said; Legrand, Matthieu; Placido, Rui; Manivet, Philippe; Cohen-Solal, Alain; Abraham, William T; Jessup, Mariell; Mebazaa, Alexandre
2016-12-01
Acute heart failure (AHF) with reduced left-ventricular ejection fraction (LVEF) is often a biventricular congested state. The comparative effect of vasodilators and inotropes on the right- and/or left-sided congestion is unknown. A systematic review, meta-analysis, and meta-regression of AHF studies using pulmonary artery catheter were performed using PubMed, Embase, and Cochrane library. Data from 35 studies, including 3016 patients, were studied. Included patients had a weighted mean age of 60 years, left-ventricular ejection fraction (LVEF) of 24 %, and plasma B-type natriuretic peptide (BNP) of 892 pg/ml. Both the left- and right-ventricular filling pressures were elevated: weighted mean pulmonary artery wedge pressure (PAWP) was 25 mmHg (range 17-31 mmHg) and right atrial pressure (RAP) 12 mmHg (range 7-18 mmHg). Vasodilators and inotropes had similar beneficial effects on PAWP [-6.3 mmHg (95 % CI -7.4 to -5.2 mmHg) and -5.8 mmHg (95 % CI -7.6 to -4.0 mmHg), respectively] and RAP [-2.9 mmHg (95 % CI -3.8 to -2.1 mmHg) and -2.8 mmHg (95 % CI -3.8 to -1.7 mmHg), respectively]. Among inotropes, inodilators, such as levosimendan, have greater beneficial effect on the left-ventricular filling pressure than dobutamine. Drug-induced improvement of PAWP tightly paralleled that of RAP with all studied drugs (r 2 = 0.90, p < 0.001). Vasodilators and inotropes had no short-term effect of renal function. The left- and right-sided filling pressures are similarly improved by vasodilators or inotropes, in AHF with reduced LVEF.
Oxygen and carbon dioxide transport in time-dependent blood flow past fiber rectangular arrays
NASA Astrophysics Data System (ADS)
Zierenberg, Jennifer R.; Fujioka, Hideki; Hirschl, Ronald B.; Bartlett, Robert H.; Grotberg, James B.
2009-03-01
The influence of time-dependent flows on oxygen and carbon dioxide transport for blood flow past fiber arrays arranged in in-line and staggered configurations was computationally investigated as a model for an artificial lung. Both a pulsatile flow, which mimics the flow leaving the right heart and passing through a compliance chamber before entering the artificial lung, and a right ventricular flow, which mimics flow leaving the right heart and directly entering the artificial lung, were considered in addition to a steady flow. The pulsatile flow was modeled as a sinusoidal perturbation superimposed on a steady flow while the right ventricular flow was modeled to accurately depict the period of flow acceleration (increasing flow) and deceleration (decreasing flow) during systole followed by zero flow during diastole. It was observed that the pulsatile flow yielded similar gas transport as compared to the steady flow, while the right ventricular flow resulted in smaller gas transport, with the decrease increasing with Re. The pressure drop across the fiber array (a measure of the resistance), work (an indicator of the work required of the right heart), and shear stress (a measure of potential blood cell activation and damage) are lowest for steady flow, followed by pulsatile flow, and then right ventricular flow. The pressure drop, work, shear stress, and Sherwood numbers (a measure of the gas transport efficiency) decrease with increasing porosity and are smaller for AR <1 as compared to AR >1 (AR is the distance between fibers in the flow direction/distance between fibers in direction perpendicular to flow), although for small porosities the Sherwood numbers are of similar magnitude. In general, for any fiber array geometry, high pressure drop, work, and shear stresses correlate with high Sherwood numbers, and low pressure drop, work, and shear stresses correlate with low Sherwood numbers creating a need for a compromise between pressure drop/work/shear stresses and gas transport.
Kerckhoffs, Roy C.P.; Omens, Jeffrey; McCulloch, Andrew D.
2011-01-01
Adult cardiac muscle adapts to mechanical changes in the environment by growth and remodeling (G&R) via a variety of mechanisms. Hypertrophy develops when the heart is subjected to chronic mechanical overload. In ventricular pressure overload (e.g. due to aortic stenosis) the heart typically reacts by concentric hypertrophic growth, characterized by wall thickening due to myocyte radial growth when sarcomeres are added in parallel. In ventricular volume overload, an increase in filling pressure (e.g. due to mitral regurgitation) leads to eccentric hypertrophy as myocytes grow axially by adding sarcomeres in series leading to ventricular cavity enlargement that is typically accompanied by some wall thickening. The specific biomechanical stimuli that stimulate different modes of ventricular hypertrophy are still poorly understood. In a recent study, based on in-vitro studies in micropatterned myocyte cell cultures subjected to stretch, we proposed that cardiac myocytes grow longer to maintain a preferred sarcomere length in response to increased fiber strain and grow thicker to maintain interfilament lattice spacing in response to increased cross-fiber strain. Here, we test whether this growth law is able to predict concentric and eccentric hypertrophy in response to aortic stenosis and mitral valve regurgitation, respectively, in a computational model of the adult canine heart coupled to a closed loop model of circulatory hemodynamics. A non-linear finite element model of the beating canine ventricles coupled to the circulation was used. After inducing valve alterations, the ventricles were allowed to adapt in shape in response to mechanical stimuli over time. The proposed growth law was able to reproduce major acute and chronic physiological responses (structural and functional) when integrated with comprehensive models of the pressure-overloaded and volume-overloaded canine heart, coupled to a closed-loop circulation. We conclude that strain-based biomechanical stimuli can drive cardiac growth, including wall thickening during pressure overload. PMID:22639476
Liu, Li; Wang, Wen; Meng, Xianmin; Gao, Jiuming; Wu, Haiying; Wang, Peihe; Wu, Weichun; Wang, Linlin; Ma, Liyuan; Zhang, Weiguo
2010-12-01
Cardiac hypertrophy is frequently caused by pressure overload (i.e., high blood pressure or hypertension) and can lead to heart failure. The major objective of the present study was to investigate the proteomic changes in response to the development of left ventricular hypertrophy (LVH) induced by abdominal aortic banding (AB) and its prevention by antihypertensive treatment with angiotensin II receptor blocker (ARB) telmisartan. One week after AB and Sham surgery, rats were assigned into three groups: SHAM-control, aortic banding without treatment (AB-Ctrl) and aortic banding with telmisartan treatment (AB-Telmi; 5mg/kg/day for 8 weeks). Echocardiography, hemodynamics, and pathology were performed to assess LVH. Left ventricular myocardium was sampled. The analysis of proteomic proteins from myocardium was performed by two-dimensional gel electrophoresis and MALDI-TOF-MS. In AB-Ctrl, heart rate, systolic arterial blood pressure, diastolic blood pressure, left ventricular end systolic pressure, interventricular septal thickness at diastole, posterior wall thickness in diastole, heart weight (HW) and HW/body weight (BW) were increased, indicating that both hypertension and LVH developed. Telmisartan prevented hypertension and LVH. Concurrently, among numerous proteins, there were 17 that were differentially expressed among hypertrophic hearts, normal hearts, and the hearts where hypertrophic response was suppressed by ARB treatment. Primarily, proteins involved in cell structure, metabolism, stress and signal transduction exhibited up-regulations in LVH, providing cellular and molecular mechanism for hypertrophic development. These changes were prevented or greatly attenuated by telmisartan regimen. Interestingly, antioxidative-related heat shock protein 2 was detected neither in SHAM-Ctrl nor in AB-Ctrl, but in AB-Telmi. LVH is accompanied by series changes of protein expression. Both LVH and proteomic changes can be prevented by blockade of renin-angiotensin system with telmisartan. These protein alterations may constitute mechanistic pathways leading to hypertrophy development and experimental targets for novel therapeutic strategy.
Wemmelund, K B; Lie, R H; Juhl-Olsen, P; Frederiksen, C A; Hermansen, J F; Sloth, E
2012-08-01
Although pleural effusion is a common complication in critically ill patients, detailed knowledge is missing about the haemodynamic impact and the underlining mechanisms. The aim of this study was to evaluate the haemodynamic effect of incremental pleural effusion by means of invasive haemodynamic parameters and transthoracic echocardiography. This experimental interventional study was conducted using 22 female piglets (17.5-21.5 kg) randomized for right-side (n = 9) and left-side (n = 9) pleural effusion, or sham operation (n = 4). Pleural effusion was induced by infusing incremental volumes of saline into the pleural cavity. Invasive haemodynamic measurements and echocardiographical images were obtained at baseline, a volume of 45 ml/kg, a volume of 75 ml/kg and 45 min after drainage. No difference (all P > 0.147) was found between right- and left-side pleural effusion, and the groups were thus pooled. At 45 ml/kg cardiac output, mean arterial pressure, stroke volume and mixed venous saturation decreased (all P < 0.003); central venous pressure and pulmonary arterial pressure increased (both P > 0.003) at this point. The changes accelerated at 75 ml/kg. At 45 ml/kg left ventricular pre-load in terms of end-diastolic area decreased significantly (P < 0.001). The effect on haemodynamics and cardiac dimensions changed dramatically at 75 ml/kg. Cardiac output, mean arterial pressure, central venous pressure and left ventricular end-diastolic area returned to normal during a recovery period of 45 min (all P > 0.061). Incremental volumes of unilateral pleural effusion induced a significant haemodynamic impact fully reversible after drainage. Pleural effusion causes a significant decrease of left ventricular pre-load in a diverse picture of haemodynamic compromise. © 2012 The Authors. Acta Anaesthesiologica Scandinavica © 2012 The Acta Anaesthesiologica Scandinavica Foundation.
Rationale and Description of Right Ventricle-Protective Ventilation in ARDS.
Paternot, Alexis; Repessé, Xavier; Vieillard-Baron, Antoine
2016-10-01
Pulmonary vascular dysfunction is associated with ARDS and leads to increased right-ventricular afterload and eventually right-ventricular failure, also called acute cor pulmonale. Interest in acute cor pulmonale and its negative impact on outcome in patients with ARDS has grown in recent years. Right-ventricular function in these patients should be closely monitored, and this is helped by the widespread use of echocardiography in intensive care units. Because mechanical ventilation may worsen right-ventricular failure, the interaction between the lungs and the right ventricle appears to be a key factor in the ventilation strategy. In this review, a rationale for a right ventricle-protective ventilation approach is provided, and such a strategy is described, including the reduction of lung stress (ie, the limitation of plateau pressure and driving pressure), the reduction of PaCO2 , and the improvement of oxygenation. Prone positioning seems to be a crucial part of this strategy by protecting both the lungs and the right ventricle, resulting in increased survival of patients with ARDS. Further studies are required to validate the positive impact on prognosis of right ventricle-protective mechanical ventilation. Copyright © 2016 by Daedalus Enterprises.
Liu, Xiaoyu; Kwak, Dongmin; Lu, Zhongbing; Xu, Xin; Fassett, John; Wang, Huan; Wei, Yidong; Cavener, Douglas R; Hu, Xinli; Hall, Jennifer; Bache, Robert J; Chen, Yingjie
2014-10-01
Studies have reported that development of congestive heart failure is associated with increased endoplasmic reticulum stress. Double stranded RNA-activated protein kinase R-like endoplasmic reticulum kinase (PERK) is a major transducer of the endoplasmic reticulum stress response and directly phosphorylates eukaryotic initiation factor 2α, resulting in translational attenuation. However, the physiological effect of PERK on congestive heart failure development is unknown. To study the effect of PERK on ventricular structure and function, we generated inducible cardiac-specific PERK knockout mice. Under unstressed conditions, cardiac PERK knockout had no effect on left ventricular mass, or its ratio to body weight, cardiomyocyte size, fibrosis, or left ventricular function. However, in response to chronic transverse aortic constriction, PERK knockout mice exhibited decreased ejection fraction, increased left ventricular fibrosis, enhanced cardiomyocyte apoptosis, and exacerbated lung remodeling in comparison with wild-type mice. PERK knockout also dramatically attenuated cardiac sarcoplasmic reticulum Ca(2+)-ATPase expression in response to aortic constriction. Our findings suggest that PERK is required to protect the heart from pressure overload-induced congestive heart failure. © 2014 American Heart Association, Inc.
Yu, C; Liu, Y; Zhu, X; Li, Y; Li, Y
2000-03-01
To compare the hemodynamic effect and energy loss of atrio-ventricular and total cavo-pulmonary connections versus atrio-pulmonary anastomosis for modified Fontan in dogs. Fifteen adult mongrel dogs were divided into three groups. Group I underwent right atrium to right ventricle (using 50% and 25% right ventricular chamber, respectively) connection with the flap of valved homo-pulmonary artery (modified Bjoerk procedure). Group II underwent total cavo-pulmonary connection. Group III received atrio-pulmonary anastomosis. Right atrium pressure, pulmonary artery pressure, and cardiac output were measured by Swan-Ganz catheter. The volumes of the right pulmonary artery, left pulmonary artery, superior vena cava and inferior vena cava were measured by electromagnetic flowmeter. The flow-rate of the right pulmonary artery, left pulmonary artery, superior vena cava and inferior vena cava were measured echocardiographically. The fluid energy loss was calculated. The postoperative right atrium pressure in group I was lower than in group III (P < 0.05). The postoperative stroke index in group I and group II was higher than in group III (P < 0.01). The fluid energy loss was decreased when 50% or 25% right ventricle chamber was used (P < 0.01) and the fluid energy less in group II was less than in group III. Our experience suggested that atrio-ventricular connection and total cavo-pulmonary connection would be better than atrio-pulmonary anastomosis for modified Fontan repair of tricuspid valve atresia.
Blood pressure response is impaired in patients with exercise-induced ventricular ectopy.
Turan, Oguzhan Ekrem; Ozturk, Mustafa; Kocaoglu, Ibrahim; Turan, Selen Gursoy
2016-05-01
Exercise-induced ventricular ectopy (EIVE) has clinical and prognostic significance. But the mechanism underlying EIVE-related mortality still remains unclear. This study aims to assess blood pressure alteration in patients with EIVE and to identify the potential causes of increased mortality in this patient group. A total number of 3611 patients were screened within a 1-year period, and patients with a structural heart disease, coronary artery disease, hypertension, diabetes mellitus, thyroid dysfunction, and chronic renal disease were excluded from the study. A total number of 98 patients with no chronic disease, who were retrospectively diagnosed with EIVE, were included in the study as patient group and 116 patients without EIVE were included as control group. The median age, gender distribution, laboratory test results, and echocardiographic findings were similar between the two groups. Systolic blood pressure (SBP) alterations during exercise stress testing were found to be significantly different (P < .001). Moreover, EIVE group had significantly higher peak SBP (P < .001). A significant positive relation was found between peak SBP level and ventricular ectopy count (r:0.27, P = .006). Our study showed that EIVE patients without a structural heart disease or a chronic disease had higher peak SBP levels. Higher SBP alteration can be related to ventricular ectopy occurrence during exercise stress testing, which can be a possible reason underlying the increased rate of mortality among EIVE patients. Copyright © 2016 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
Freeman, G L; Colston, J T; Miller, D D
1994-01-01
The purpose of this study was to evaluate whether abnormalities of free fatty acid metabolism are present before the onset of overt mechanical dysfunction in dogs with tachycardia-induced heart failure. We studied six dogs chronically instrumented to allow assessment of left ventricular function in the pressure-volume plane. Free fatty acid clearance was assessed according to the washout rate of a free fatty acid analog, iodophenylpentadecanoic acid ([123I]PPA or IPPA). IPPA clearance was measured within 1 hour of the hemodynamic assessment. The animals were studied under baseline conditions and 11.7 +/- 3.6 days after ventricular pacing at a rate of 240 beats/min. Hemodynamic studies after pacing showed a nonsignificant increase in left ventricular end-diastolic pressure (11.7 +/- 4.7 to 17.4 +/- 6.5 mm Hg) and a nonsignificant decrease in the maximum derivative of pressure with respect to time (1836 +/- 164 vs 1688 +/- 422 mm Hg/sec). There was also no change in the time constant of left ventricular relaxation, which was 34.8 +/- 7.67 msec before and 35.3 +/- 7.3 msec after pacing. However, a significant prolongation in the clearance half-time of [123I]PPA, from 86.1 +/- 23.9 to 146.5 +/- 22.6 minutes (p < 0.01) was found. Thus abnormal lipid clearance appears before the onset of significant mechanical dysfunction in tachycardia-induced heart failure. This suggests that abnormal substrate metabolism may play an important role in the pathogenesis of this condition.
Hakim, R; Black, P M
1998-01-01
After the initial description of normal pressure hydrocephalus (NPH) and its clinical triad, there has been a continuous interest from clinicians and researchers to set different diagnostic criteria that would make the selection of candidates for shunt surgery easier and more precise. A preliminary group of 12 patients was given a diagnosis of idiopathic normal pressure hydrocephalus by clinical and radiologic criteria. Each patient underwent two different tests: a magnetic resonance imaging-cerebrospinal fluid (MRI-CSF) flow study and a lumbo-ventricular perfusion test. The purpose was to compare the correlation of the results obtained with these tests and the clinical results obtained after CSF diversion. Eleven patients were given shunts and one was managed with lumbar punctures. One year after treatment, 10 of the 12 patients had improved with good results. The MRI-CSF flow studies were reliable in six patients; there were five false negatives and one false positive. The lumbo-ventricular perfusion test showed reliability in nine patients; there were two false negatives and one false positive. In only three patients were the results of both of these tests in accordance with the outcome. Even though there are few patients in this study so far, the data suggests that at the present time the most predictive guides for the diagnosis of NPH and its outcome after shunting are the clinical criteria and the radiological findings in computed tomography (CT) and/or MRI rather than lumbo-ventricular perfusion and CSF flow studies.
Double product and end-organ damage in African and Caucasian men: the SABPA study.
Schultz, A J; Schutte, A E; Schutte, R
2013-08-10
Increasing urbanisation in sub-Saharan African countries is causing a rapid increase in cardiovascular disease. Evidence suggests that Africans have higher blood pressures and a higher prevalence of hypertension-related cardiovascular morbidity and mortality, compared to Caucasians. We investigated double product (systolic blood pressure × heart rate), a substantial measure of cardiac workload, as a possible cardiovascular risk factor in African and Caucasian men. The study consisted of 101 urbanised African and 101 Caucasian male school teachers. We measured 24h ambulatory blood pressure and the carotid cross-sectional wall area, and determined left ventricular hypertrophy electrocardiographically by means of the Cornell product. Urinary albumin and creatinine were analysed to obtain the albumin-to-creatinine ratio. Africans had higher 24h, daytime and nighttime systolic- and diastolic blood pressure, heart rate and resultant double product compared to the Caucasians. In addition, markers of end-organ damage, albumin-to-creatinine ratio and left ventricular hypertrophy were higher in the Africans while cross-sectional wall area did not differ. In Africans after single partial and multiple regression analysis, 24h systolic blood pressure, but not double product or heart rate, correlated positively with markers of end-organ damage (cross-sectional wall area: β=0.398, P=0.005; left ventricular hypertrophy: β=0.455, P<0.001; albumin-to-creatinine ratio: β=0.280, P=0.012). No associations were evident in Caucasian men. Double product may not be a good marker of increased cardiovascular risk when compared to systolic blood pressure in African and Caucasian men. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
LRRC10 is required to maintain cardiac function in response to pressure overload.
Brody, Matthew J; Feng, Li; Grimes, Adrian C; Hacker, Timothy A; Olson, Timothy M; Kamp, Timothy J; Balijepalli, Ravi C; Lee, Youngsook
2016-01-15
We previously reported that the cardiomyocyte-specific leucine-rich repeat containing protein (LRRC)10 has critical functions in the mammalian heart. In the present study, we tested the role of LRRC10 in the response of the heart to biomechanical stress by performing transverse aortic constriction on Lrrc10-null (Lrrc10(-/-)) mice. Mild pressure overload induced severe cardiac dysfunction and ventricular dilation in Lrrc10(-/-) mice compared with control mice. In addition to dilation and cardiomyopathy, Lrrc10(-/-) mice showed a pronounced increase in heart weight with pressure overload stimulation and a more dramatic loss of cardiac ventricular performance, collectively suggesting that the absence of LRRC10 renders the heart more disease prone with greater hypertrophy and structural remodeling, although rates of cardiac fibrosis and myocyte dropout were not different from control mice. Lrrc10(-/-) cardiomyocytes also exhibited reduced contractility in response to β-adrenergic stimulation, consistent with loss of cardiac ventricular performance after pressure overload. We have previously shown that LRRC10 interacts with actin in the heart. Here, we show that His(150) of LRRC10 was required for an interaction with actin, and this interaction was reduced after pressure overload, suggesting an integral role for LRRC10 in the response of the heart to mechanical stress. Importantly, these experiments demonstrated that LRRC10 is required to maintain cardiac performance in response to pressure overload and suggest that dysregulated expression or mutation of LRRC10 may greatly sensitize human patients to more severe cardiac disease in conditions such as chronic hypertension or aortic stenosis. Copyright © 2016 the American Physiological Society.
Apitz, Christian; Honjo, Osami; Humpl, Tilman; Li, Jing; Assad, Renato S; Cho, Mi Y; Hong, James; Friedberg, Mark K; Redington, Andrew N
2012-12-01
Chronic right ventricular (RV) pressure overload results in pathologic RV hypertrophy and diminished RV function. Although aortic constriction has been shown to improve systolic function in acute RV failure, its effect on RV responses to chronic pressure overload is unknown. Adjustable vascular banding devices were placed on the main pulmonary artery and descending aorta. In 5 animals (sham group), neither band was inflated. In 9 animals (PAB group), only the pulmonary arterial band was inflated, with adjustments on a weekly basis to generate systemic or suprasystemic RV pressure at 28 days. In 9 animals, both pulmonary arterial and aortic devices were inflated (PAB + AO group), the pulmonary arterial band as for the PAB group and the aortic band adjusted to increase proximal systolic blood pressure by approximately 20 mm Hg. Effects on the functional performance were assessed 5 weeks after surgery by conductance catheters, followed by histologic and molecular assessment. Contractile performance was significantly improved in the PAB + AO group versus the PAB group for both ventricles. Relative to sham-operated animals, both banding groups showed significant differences in myocardial histologic and molecular responses. Relative to the PAB group, the PAB + AO group showed significantly decreased RV cardiomyocyte diameter, decreased RV collagen content, and reduced RV expression of endothelin receptor type B, matrix metalloproteinase 9, and transforming growth factor β genes. Aortic constriction in an experimental model of chronic RV pressure overload not only resulted in improved biventricular systolic function but also improved myocardial remodeling. These data suggest that chronically increased left ventricular afterload leads to a more physiologically hypertrophic response in the pressure-overloaded RV. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Van Herck, P L; Carlier, S G; Claeys, M J; Haine, S E; Gorissen, P; Miljoen, H; Bosmans, J M; Vrints, C J
2007-01-01
Objective To investigate the underlying mechanisms of a decreased coronary flow reserve after myocardial infarction (MI) by analysing the characteristics of the diastolic hyperaemic coronary pressure–flow relationship. Design Prospective study. Setting Tertiary care hospital. Patients 68 patients with a recent MI and 27 patients with stable angina pectoris (AP; control group). Main outcome measures The intercept with the pressure axis (the zero flow pressure or Pzf) and slope index of the pressure–flow relationship (SIPF) were calculated from the simultaneously recorded hyperaemic intracoronary blood flow velocity and aortic pressure after successful coronary stenting. Results A stepwise increase in Pzf from AP (14.6 (8.0) mm Hg), over non‐Q‐wave MI (22.5 (9.1) mm Hg), to Q‐wave MI (37.1 (12.9) mm Hg; p<0.001) was observed. Similar changes in Pzf were found in a reference artery perfusing the non‐infarcted myocardium. Multivariate analysis showed that in both regions the left ventricular end‐diastolic pressure (LVEDP) was the most important determinant of the Pzf. The SIPF was not statistically different in the treated vessel between patients with MI and AP, but was increased in MI patients with a markedly increased LVEDP. Conclusions After an MI, the coronary pressure–flow relationship is shifted to the right both in the infarcted and in the non‐infarcted remote myocardium, as shown by the increased Pzf. The correlation with Pzf suggests that elevated left ventricular filling pressures contribute to the impediment of myocardial perfusion in patients with infarction. PMID:17395671
Adamson, Philip B; Magalski, Anthony; Braunschweig, Frieder; Böhm, Michael; Reynolds, Dwight; Steinhaus, David; Luby, Allyson; Linde, Cecilia; Ryden, Lars; Cremers, Bodo; Takle, Teri; Bennett, Tom
2003-02-19
This study examined the characteristics of continuously measured right ventricular (RV) hemodynamic information derived from an implantable hemodynamic monitor (IHM) in heart failure patients. Hemodynamic monitoring might improve the day-to-day management of patients with chronic heart failure (CHF). Little is known about the characteristics of long-term hemodynamic information in patients with CHF or how such information relates to meaningful clinical events. Thirty-two patients with CHF received a permanent RV IHM system similar to a single-lead pacemaker. Right ventricular systolic and diastolic pressures, heart rate, and pressure derivatives were continuously measured for nine months without using the data for clinical decision-making or management of patients. Data were then made available to clinical providers, and the patients were followed up for 17 months. Pressure characteristics during optimal volume, clinically determined volume-overload exacerbations, and volume depletion events were examined. The effect of IHM on hospitalizations was examined using the patients' historical controls. Long-term RV pressure measurements had either marked variability or minimal time-related changes. During 36 volume-overload events, RV systolic pressures increased by 25 +/- 4% (p < 0.05) and heart rate increased by 11 +/- 2% (p < 0.05). Pressure increases occurred in 9 of 12 events 4 +/- 2 days before the exacerbations requiring hospitalization. Hospitalizations before using IHM data for clinical management averaged 1.08 per patient year and decreased to 0.47 per patient-year (57% reduction, p < 0.01) after hemodynamic data were used. Long-term ambulatory pressure measurements from an IHM may be helpful in guiding day-to-day clinical management, with a potentially favorable impact on CHF hospitalizations.
Shin, Il-Woo; Hah, Young-Sool; Kim, Cheol; Park, Jungchul; Shin, Heewon; Park, Kyeong-Eon; Ok, Seong-Ho; Lee, Heon-Keun; Chung, Young-Kyun; Shim, Haeng Seon; Lim, Dong Hoon; Sohn, Ju-Tae
2014-01-01
Intravenous lipid emulsions (LEs) are effective in the treatment of toxicity associated with various drugs such as local anesthetics and other lipid soluble agents. The goals of this study were to examine the effect of LE on left ventricular hemodynamic variables and systemic blood pressure in an in vivo rat model, and to determine the associated cellular mechanism with a particular focus on nitric oxide. Two LEs (Intralipid(®) 20% and Lipofundin(®) MCT/LCT 20%) or normal saline were administered intravenously in an in vivo rat model following induction of anesthesia by intramuscular injection of tiletamine/zolazepam and xylazine. Left ventricular systolic pressure (LVSP), blood pressure, heart rate, maximum rate of intraventricular pressure increase, and maximum rate of intraventricular pressure decrease were measured before and after intravenous administration of various doses of LEs or normal saline to an in vivo rat with or without pretreatment with the non-specific nitric oxide synthase inhibitor N(ω)-nitro-L-arginine-methyl ester (L-NAME). Administration of Intralipid(®) (3 and 10 ml/kg) increased LVSP and decreased heart rate. Pretreatment with L-NAME (10 mg/kg) increased LSVP and decreased heart rate, whereas subsequent treatment with Intralipid(®) did not significantly alter LVSP. Intralipid(®) (10 ml/kg) increased mean blood pressure and decreased heart rate. The increase in LVSP induced by Lipofundin(®) MCT/LCT was greater than that induced by Intralipid(®). Intralipid(®) (1%) did not significantly alter nitric oxide donor sodium nitroprusside-induced relaxation in endothelium-denuded rat aorta. Taken together, systemic blockage of nitric oxide synthase by L-NAME increases LVSP, which is not augmented further by intralipid(®).
NASA Technical Reports Server (NTRS)
Ghista, D. N.; Hamid, M. S.
1977-01-01
The three-dimensional left ventricular chamber geometrical model is developed from single plane cineangiocardiogram. This left ventricular model is loaded by an internal pressure monitored by cardiac catheterization. The resulting stresses in the left ventricular model chamber's wall are determined by computerized finite element procedure. For the discretization of this left ventricular model structure, a 20-node, isoparametric finite element is employed. The analysis and formulation of the computerised procedure is presented in the paper, along with the detailed algorithms and computer programs. The procedure is applied to determine the stresses in a left ventricle at an instant, during systole. Next, a portion (represented by a finite element) of this left ventricular chamber is simulated as being infarcted by making its active-state modulus value equal to its passive-state value; the neighbouring elements are shown to relieve the 'infarcted' element of stress by themselves taking on more stress.
Al Shehri, Abdullah M; El-Tahan, Mohamed R; Al Metwally, Roshdi; Qutub, Hatem; El Ghoneimy, Yasser F; Regal, Mohamed A; Zien, Haytham
2014-08-01
To test the effects of pressure-controlled (PCV) and volume-controlled (VCV) ventilation during one-lung ventilation (OLV) for thoracic surgery on right ventricular (RV) function. A prospective, randomized, double-blind, controlled, crossover study. A single university hospital. Fourteen pairs of consecutive patients scheduled for elective thoracotomy. Patients were assigned randomly to ventilate the dependent lung with PCV or VCV mode, each in a randomized crossover order using tidal volume of 6 mL/kg, I: E ratio 1: 2.5, positive end-expiratory pressure (PEEP) of 5 cm H2O and respiratory rate adjusted to maintain normocapnia. Intraoperative changes in RV function (systolic and early diastolic tricuspid annular velocity (TAV), end-systolic volume (ESV), end-diastolic volume (EDV) and fractional area changes (FAC)), airway pressures, compliance and oxygenation index were recorded. The use of PCV during OLV resulted in faster systolic (10.1±2.39 vs. 5.8±1.67 cm/s, respectively), diastolic TAV (9.2±1.99 vs. 4.6±1.42 cm/s, respectively) (p<0.001) and compliance and lower ESV, EDV and airway pressures (p<0.05) than during the use of VCV. Oxygenation indices were similar during the use of VCV and PCV. The use of PCV offers more improved RV function than the use of VCV during OLV for open thoracotomy. These results apply specifically to younger patients with good ventricular and pulmonary functions. © 2014 Elsevier Inc. All rights reserved.