NASA Technical Reports Server (NTRS)
Steele, P.; Kirch, D.
1975-01-01
In 47 men with arteriographically defined coronary artery disease comparative studies of left ventricular ejection fraction and segmental wall motion were made with radionuclide data obtained from the image intensifier camera computer system and with contrast cineventriculography. The radionuclide data was digitized and the images corresponding to left ventricular end-diastole and end-systole were identified from the left ventricular time-activity curve. The left ventricular end-diastolic and end-systolic images were subtracted to form a silhouette difference image which described wall motion of the anterior and inferior left ventricular segments. The image intensifier camera allows manipulation of dynamically acquired radionuclide data because of the high count rate and consequently improved resolution of the left ventricular image.
Zhu, Liangjia; Gao, Yi; Appia, Vikram; Yezzi, Anthony; Arepalli, Chesnal; Faber, Tracy; Stillman, Arthur; Tannenbaum, Allen
2014-01-01
The left ventricular myocardium plays a key role in the entire circulation system and an automatic delineation of the myocardium is a prerequisite for most of the subsequent functional analysis. In this paper, we present a complete system for an automatic segmentation of the left ventricular myocardium from cardiac computed tomography (CT) images using the shape information from images to be segmented. The system follows a coarse-to-fine strategy by first localizing the left ventricle and then deforming the myocardial surfaces of the left ventricle to refine the segmentation. In particular, the blood pool of a CT image is extracted and represented as a triangulated surface. Then, the left ventricle is localized as a salient component on this surface using geometric and anatomical characteristics. After that, the myocardial surfaces are initialized from the localization result and evolved by applying forces from the image intensities with a constraint based on the initial myocardial surface locations. The proposed framework has been validated on 34-human and 12-pig CT images, and the robustness and accuracy are demonstrated. PMID:24723531
Automatically measuring brain ventricular volume within PACS using artificial intelligence.
Yepes-Calderon, Fernando; Nelson, Marvin D; McComb, J Gordon
2018-01-01
The picture archiving and communications system (PACS) is currently the standard platform to manage medical images but lacks analytical capabilities. Staying within PACS, the authors have developed an automatic method to retrieve the medical data and access it at a voxel level, decrypted and uncompressed that allows analytical capabilities while not perturbing the system's daily operation. Additionally, the strategy is secure and vendor independent. Cerebral ventricular volume is important for the diagnosis and treatment of many neurological disorders. A significant change in ventricular volume is readily recognized, but subtle changes, especially over longer periods of time, may be difficult to discern. Clinical imaging protocols and parameters are often varied making it difficult to use a general solution with standard segmentation techniques. Presented is a segmentation strategy based on an algorithm that uses four features extracted from the medical images to create a statistical estimator capable of determining ventricular volume. When compared with manual segmentations, the correlation was 94% and holds promise for even better accuracy by incorporating the unlimited data available. The volume of any segmentable structure can be accurately determined utilizing the machine learning strategy presented and runs fully automatically within the PACS.
Vargas-Barron, Jesús; Antunez-Montes, Omar-Yassef; Roldán, Francisco-Javier; Aranda-Frausto, Alberto; González-Pacheco, Hector; Romero-Cardenas, Ángel; Zabalgoitia, Miguel
2015-01-01
Torrent-Guasp explains the structure of the ventricular myocardium by means of a helical muscular band. Our primary purpose was to demonstrate the utility of echocardiography in human and porcine hearts in identifying the segments of the myocardial band. The second purpose was to evaluate the relation of the topographic distribution of the myocardial band with some post-myocardial infarction ruptures. Five porcine and one human heart without cardiopathy were dissected and the ventricular myocardial segments were color-coded for illustration and reconstruction purposes. These segments were then correlated to the conventional echocardiographic images. Afterwards in three cases with post-myocardial infarction rupture, a correlation of the topographic location of the rupture with the distribution of the ventricular band was made. The human ventricular band does not show any differences from the porcine band, which confirms the similarities of the four segments; these segments could be identified by echocardiography. In three cases with myocardial rupture, a correlation of the intra-myocardial dissection with the distribution of the ventricular band was observed. Echocardiography is helpful in identifying the myocardial band segments as well as the correlation with the topographic distribution of some myocardial post-infarction ruptures.
Clinical application of a light-pen computer system for quantitative angiography
NASA Technical Reports Server (NTRS)
Alderman, E. L.
1975-01-01
The paper describes an angiographic analysis system which uses a video disk for recording and playback, a light-pen for data input, minicomputer processing, and an electrostatic printer/plotter for hardcopy output. The method is applied to quantitative analysis of ventricular volumes, sequential ventriculography for assessment of physiologic and pharmacologic interventions, analysis of instantaneous time sequence of ventricular systolic and diastolic events, and quantitation of segmental abnormalities. The system is shown to provide the capability for computation of ventricular volumes and other measurements from operator-defined margins by greatly reducing the tedium and errors associated with manual planimetry.
Clustering Of Left Ventricular Wall Motion Patterns
NASA Astrophysics Data System (ADS)
Bjelogrlic, Z.; Jakopin, J.; Gyergyek, L.
1982-11-01
A method for detection of wall regions with similar motion was presented. A model based on local direction information was used to measure the left ventricular wall motion from cineangiographic sequence. Three time functions were used to define segmental motion patterns: distance of a ventricular contour segment from the mean contour, the velocity of a segment and its acceleration. Motion patterns were clustered by the UPGMA algorithm and by an algorithm based on K-nearest neighboor classification rule.
de Oliveira, Luciano Fonseca Lemos; Romano, Minna Moreira Dias; de Carvalho, Eduardo Elias Vieira; Cabeza, Jorge Mejia; Salgado, Hélio Cesar; Fazan Júnior, Rubens; Costa, Renata Sesti; da Silva, João Santana; Higuchi, Maria de Lourdes; Maciel, Benedito Carlos; Cunha-Neto, Edécio; Marin-Neto, José Antônio; Simões, Marcus Vinícius
2016-01-21
Chronic Chagas cardiomyopathy in humans is characterized by segmental left ventricular wall motion abnormalities (WMA), mainly in the early stages of disease. This study aimed at investigating the detection of WMA and its correlation with the underlying histopathological changes in a chronic Chagas cardiomyopathy model in hamsters. Female Syrian hamsters (n=34) infected with 3.5×10(4) or 10(5) blood trypomastigote Trypanosoma cruzi (Y strain) forms and an uninfected control group (n=7) were investigated. After 6 or 10 months after the infection, the animals were submitted to in vivo evaluation of global and segmental left ventricular systolic function by echocardiography, followed by euthanasia and histological analysis for quantitative assessment of fibrosis and inflammation with tissue sampling in locations coinciding with the left ventricular wall segmentation employed at the in vivo echocardiographic evaluation. Ten of the 34 infected animals (29%) showed reduced left ventricular ejection fraction (<73%). Left ventricular ejection fraction was more negatively correlated with the intensity of inflammation (r=-0.63; P<0.0001) than with the extent of fibrosis (r=-0.36; P=0.036). Among the 24 animals with preserved left ventricular ejection fraction (82.9±5.5%), 8 (33%) showed segmental WMA predominating in the apical, inferior, and posterolateral segments. The segments exhibiting WMA, in comparison to those with normal wall motion, showed a greater extent of fibrosis (9.3±5.7% and 7±6.3%, P<0.0001) and an even greater intensity of inflammation (218.0±111.6 and 124.5±84.8 nuclei/mm², P<0.0001). Isolated WMA with preserved global systolic left ventricular function is frequently found in Syrian hamsters with experimental chronic Chagas cardiomyopathy whose underlying histopathological features are mainly inflammatory. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Chasing the reflected wave back into the heart: a new hypothesis while the jury is still out
Codreanu, Ion; Robson, Matthew D; Rider, Oliver J; Pegg, Tammy J; Jung, Bernd A; Dasanu, Constantin A; Clarke, Kieran; Holloway, Cameron J
2011-01-01
Background: Arterial stiffness directly influences cardiac function and is independently associated with cardiovascular risk. However, the influence of the aortic reflected pulse pressure wave on left ventricular function has not been well characterized. The aim of this study was to obtain detailed information on regional ventricular wall motion patterns corresponding to the propagation of the reflected aortic wave on ventricular segments. Methods: Left ventricular wall motion was investigated in a group of healthy volunteers (n = 14, age 23 ± 3 years), using cardiac magnetic resonance navigator-gated tissue phase mapping. The left ventricle was divided into 16 segments and regional wall motion was studied in high temporal detail. Results: Corresponding to the expected timing of the reflected aortic wave reaching the left ventricle, a characteristic “notch” of regional myocardial motion was seen in all radial, circumferential, and longitudinal velocity graphs. This notch was particularly prominent in septal segments adjacent to the left ventricular outflow tract on radial velocity graphs and in anterior and posterior left ventricular segments on circumferential velocity graphs. Similarly, longitudinal velocity graphs demonstrated a brief deceleration in the upward recoil motion of the entire ventricle at the beginning of diastole. Conclusion: These results provide new insights into the possible influence of the reflected aortic waves on ventricular segments. Although the association with the reflected wave appears to us to be unambiguous, it represents a novel research concept, and further studies enabling the actual recording of the pulse wave are required. PMID:21731888
Left ventricular rotation and torsion in patients with perimembranous ventricular septal defect.
Zhuang, Yan; Yong, Yong-hong; Yao, Jing; Ji, Ling; Xu, Di
2014-03-01
Assessment of left ventricular (LV) rotation has become an important approach for quantifying LV function. In this study, we sought to analyze LV rotation and twist using speckle tracking imaging (STI) in adult patients with isolated ventricular septal defects. Using STI, the peak rotation and time to peak rotation of 6 segments in basal and apical short-axis were measured, respectively, in 32 patients with ventricular septal defect and 30 healthy subjects as controls. The global rotation of the 6 segments in basal and apical and LV twist versus time profile were drawn, the peak rotation and twist of LV were calculated. All the time to peak rotation/twist were expressed as a percentage of end-systole (end-systole = 100%). Left ventricular ejection fraction was measured by biplane Simpson method. In patients group, the peak rotation of posterior, inferior, and postsept wall in basal was higher(P ≤ 0.05) and LV twist was also higher (P ≤ 0.05) than healthy controls. There were no significant differences between 2 groups in the peak rotation of the other 9 segments and left ventricular ejection fraction. Different from the control group, the time to peak rotation of the 6 segments in basal were delayed and the global rotation of the base was delayed (P ≤ 0.05) in ventricular septal defect group. Left ventricular volume overload due to ventricular septal defect has significant effect on LV rotation and twist, and LV rotation and twist may be a new index predicting LV systolic function. © 2013, Wiley Periodicals, Inc.
Huang, He; Jing, Xian-chao; Hu, Zhang-xue; Chen, Xi; Liu, Xiao-qin
2015-12-01
To observe the ventricular global and regional function of the patients with systemic amyloidosis using two-dimensional speckle tracking echocardiography. The study enrolled 31 consecutive biopsy-proved patients with systemic amyloidosis who underwent echocardiographic examination and EF ≥ 55% and 37 age- and gender-matched healthy controls. We compared systolic strain and strain rate, diastolic strain rate, time to peak strain, peak delay time in longitudinal, radial, circumferential directions in 16 left ventricular segments. The global peak systolic longitudinal and radial strain of left ventricle, peak systolic longitudinal strain and strain rate, diastolic strain rate of right ventricular free wall were also compared. (1) Global peak systolic longitudinal strain (GPSLS), peak systolic longitudinal strain (PSLS) and strain rate (PSLSR), peak early diastolic longitudinal strain rate (PELSR) in 16 segments were decreased in case (P < 0.05). (2) Peak systolic radial strain and strain rate of inferoseptum and inferolateral at the level of papillary muscle were lower (P < 0.05), and peak early diastolic radial strain rate (PERSR) was reduced (P < 0.05). (3) Peak early diastolic circumferential strain rate was lower (P < 0.05). (4) Time to peak systolic longitudinal, radial, circumferential strain was longer, and peak delay time at the same level retarded (P < 0.05). (5) Into right ventricular wall, PSLS and PSLSR at mid-segment, and PSLSR, PELSR, peak atrial systolic longitudinal strain rate (PALSR) at basal were reduced (P < 0.05). (6) Inverse correlation between interventricular septum (IVS) thickness and GPSLS and GPSRS was found (P < 0.05). Systolic and diastolic dysfunction existed in systemic amyloidosis with preserved EF. Mechanical contraction disorder may be one reason for systolic dysfunction. GPLSR and GPRSR were negatively related to IVS thickness. © 2015, Wiley Periodicals, Inc.
Angelini, Elsa D; Homma, Shunichi; Pearson, Gregory; Holmes, Jeffrey W; Laine, Andrew F
2005-09-01
Among screening modalities, echocardiography is the fastest, least expensive and least invasive method for imaging the heart. A new generation of three-dimensional (3-D) ultrasound (US) technology has been developed with real-time 3-D (RT3-D) matrix phased-array transducers. These transducers allow interactive 3-D visualization of cardiac anatomy and fast ventricular volume estimation without tomographic interpolation as required with earlier 3-D US acquisition systems. However, real-time acquisition speed is performed at the cost of decreasing spatial resolution, leading to echocardiographic data with poor definition of anatomical structures and high levels of speckle noise. The poor quality of the US signal has limited the acceptance of RT3-D US technology in clinical practice, despite the wealth of information acquired by this system, far greater than with any other existing echocardiography screening modality. We present, in this work, a clinical study for segmentation of right and left ventricular volumes using RT3-D US. A preprocessing of the volumetric data sets was performed using spatiotemporal brushlet denoising, as presented in previous articles Two deformable-model segmentation methods were implemented in 2-D using a parametric formulation and in 3-D using an implicit formulation with a level set implementation for extraction of endocardial surfaces on denoised RT3-D US data. A complete and rigorous validation of the segmentation methods was carried out for quantification of left and right ventricular volumes and ejection fraction, including comparison of measurements with cardiac magnetic resonance imaging as the reference. Results for volume and ejection fraction measurements report good performance of quantification of cardiac function on RT3-D data compared with magnetic resonance imaging with better performance of semiautomatic segmentation methods than with manual tracing on the US data.
Torrent-Guasp, Francisco; Kocica, Mladen J; Corno, Antonio; Komeda, Masashi; Cox, James; Flotats, A; Ballester-Rodes, Manel; Carreras-Costa, Francesc
2004-03-01
The evidence of the ventricular myocardial band (VMB) has revealed unavoidable coherence and mutual coupling of form and function in the ventricular myocardium, making it possible to understand the principles governing electrical, mechanical and energetical events within the human heart. From the earliest Erasistratus' observations, principal mechanisms responsible for the ventricular filling have still remained obscured. Contemporary experimental and clinical investigations unequivocally support the attitude that only powerful suction force, developed by the normal ventricles, would be able to produce an efficient filling of the ventricular cavities. The true origin and the precise time frame for generating such force are still controversial. Elastic recoil and muscular contraction were the most commonly mentioned, but yet, still not clearly explained mechanisms involved in the ventricular suction. Classical concepts about timing of successive mechanical events during the cardiac cycle, also do not offer understandable insight into the mechanism of the ventricular filling. The net result is the current state of insufficient knowledge of systolic and particularly diastolic function of normal and diseased heart. Here we summarize experimental evidence and theoretical backgrounds, which could be useful in understanding the phenomenon of the ventricular filling. Anatomy of the VMB, and recent proofs for its segmental electrical and mechanical activation, undoubtedly indicates that ventricular filling is the consequence of an active muscular contraction. Contraction of the ascendent segment of the VMB, with simultaneous shortening and rectifying of its fibers, produces the paradoxical increase of the ventricular volume and lengthening of its long axis. Specific spatial arrangement of the ascendent segment fibers, their interaction with adjacent descendent segment fibers, elastic elements and intra-cavitary blood volume (hemoskeleton), explain the physical principles involved in this action. This contraction occurs during the last part of classical systole and the first part of diastole. Therefore, the most important part of ventricular diastole (i.e. the rapid filling phase), in which it receives >70% of the stroke volume, belongs to the active muscular contraction of the ascendent segment. We hope that these facts will give rise to new understanding of the principal mechanisms involved in normal and abnormal diastolic heart function.
[Ebstein's "like" anomaly ventricular double inlet. A rare association].
Muñoz Castellanos, Luis; Kuri Nivon, Magdalena
The association of univentricular heart with double inlet and Ebstein's "like" anomaly of the common atrioventricular valve is extremely rare. Two hearts with this association are described with the segmental sequential system which determine the atrial situs, the types of atrioventricular and ventriculoarterial connections and associated anomalies. Both hearts had atrial situs solitus, and a univentricular heart with common atrioventricular valve, a foramen primum and double outlet ventricle with normal crossed great arteries. In the fiefirst heart the four leaflets of the atrioventricular valve were displaced and fused to the ventricular walls, from the atrioventricular union roward the apex with atrialization of the inlet and trabecular zones and there was stenosis in the infundibulum and in the pulmonary valve. In the second heart the proximal segment of the atrioventricular valve was displaced and fused to the ventricular whith shot atrialization and the distal segment was dysplastic with fibromixoid nodules and tendinous cords short and thick; the pulmonary artery was dilate. Both hearts are grouped in the atrioventricular univentricular connection in the segmental sequential system. The application of this method in the diagnosis of congenital heart disease demonstrates its usefulness. The associations of complex anomalies in these hearts show us the infinite spectrum of presentation of congenital heart disease which expands our knowledge of pediatric cardiology. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.
Direct volume estimation without segmentation
NASA Astrophysics Data System (ADS)
Zhen, X.; Wang, Z.; Islam, A.; Bhaduri, M.; Chan, I.; Li, S.
2015-03-01
Volume estimation plays an important role in clinical diagnosis. For example, cardiac ventricular volumes including left ventricle (LV) and right ventricle (RV) are important clinical indicators of cardiac functions. Accurate and automatic estimation of the ventricular volumes is essential to the assessment of cardiac functions and diagnosis of heart diseases. Conventional methods are dependent on an intermediate segmentation step which is obtained either manually or automatically. However, manual segmentation is extremely time-consuming, subjective and highly non-reproducible; automatic segmentation is still challenging, computationally expensive, and completely unsolved for the RV. Towards accurate and efficient direct volume estimation, our group has been researching on learning based methods without segmentation by leveraging state-of-the-art machine learning techniques. Our direct estimation methods remove the accessional step of segmentation and can naturally deal with various volume estimation tasks. Moreover, they are extremely flexible to be used for volume estimation of either joint bi-ventricles (LV and RV) or individual LV/RV. We comparatively study the performance of direct methods on cardiac ventricular volume estimation by comparing with segmentation based methods. Experimental results show that direct estimation methods provide more accurate estimation of cardiac ventricular volumes than segmentation based methods. This indicates that direct estimation methods not only provide a convenient and mature clinical tool for cardiac volume estimation but also enables diagnosis of cardiac diseases to be conducted in a more efficient and reliable way.
Hombach, V; Kebbel, U; Höpp, H W; Winter, U J; Braun, V; Deutsch, H; Hirche, H; Hilger, H H
1982-12-24
A new ECG-amplifier system for recording cardiac microvolt potentials from the body surface is described. The improvement in signal-to-noise ratio was achieved by using specially designed suction electrodes, which were isolated from each other; by applying parallel signal averaging from four electrode pairs via four low-noise amplifiers; and by conducting the registration in Faraday cage. in 14 normal subjects, 12 patients with coronary heart disease and one patient with surgically corrected ventricular septal defect and pulmonary stenosis, pre-P-potentials (possible sinus node activity), His bundle potentials and ventricular late potentials were recorded with differing degrees of success. Variations of the time intervals to the preceding QRS complex were observed within the S-T segment in six of nine patients with demonstrable ventricular late ventricular late potentials. The advantage of such continuously recording ECG system lies in the highly accurate registration of cardiac micropotentials, particularly with ventricular late potentials that are changing in time, whereas the signal-averaging technique does not provide such possibilities.
Vanoverschelde, J L; Wijns, W; Michel, X; Cosyns, J; Detry, J M
1991-11-01
Asynchronous segmental early relaxation, defined as a localized early segmental outward motion of the left ventricular endocardium during isovolumetric relaxation, has been associated with an altered left ventricular relaxation rate. To determine whether asynchronous segmental early relaxation also results in impaired left ventricular filling, early diastolic ventricular wall motion and Doppler-derived left ventricular filling indexes were examined in 25 patients with documented coronary artery disease and normal systolic function. Patients were further classified into two groups according to the presence (n = 15, group 1) or absence (n = 10, group 2) of asynchronous early relaxation at left ventriculography. A third group of 10 age-matched normal subjects served as a control group. No differences were observed between the two patient groups with coronary artery disease with respect to age, gender distribution, heart rate, left ventricular systolic and diastolic pressures or extent and severity of coronary artery disease. No differences in transmitral filling dynamics were observed between group 2 patients and age-matched control subjects. Conversely, group 1 patients had significantly lower peak early filling velocities (44 +/- 11 vs. 58 +/- 11 cm/s, p less than 0.01), larger atrial filling fraction (45 +/- 4% vs. 38 +/- 4%, p less than 0.001), lower ratio of early to late transmitral filling velocities (0.6 +/- 0.08 vs. 0.99 +/- 0.18, p less than 0.001) and a longer isovolumetric relaxation period (114 +/- 12 vs. 90 +/- 6 ms, p less than 0.001) compared with group 2 patients and control subjects.(ABSTRACT TRUNCATED AT 250 WORDS)
Said, Sarmad; Cooper, Chad J; Quevedo, Karla; Rodriguez, Emmanuel; Hernandez, German T
2013-01-01
Male, 22 FINAL DIAGNOSIS: Cardiomyopathy Symptoms: Shortness of breath • dispnoea • chest discomfort - Clinical Procedure: Echocardiogram • cardiac MRI Specialty: Cardiology. Challenging differential diagnosis. Non-compaction cardiomyopathy (NCM) is a rare congenital cardiomyopathy characterized by increased trabeculation in one or more segments of the ventricle. The left ventricle is most commonly affected. However, biventricular involvement or right ventricle predominance has also been described. Clinical features of NCM are non-specific and can range from being asymptomatic to symptoms of congestive heart failure, arrhythmia, and systemic thromboembolism. 22-year-old Hispanic male presented with two month history of chest discomfort. Laboratory workup revealed an elevated brain-natriuretic-peptide of 1768 pg/ml. ECG and chest x-ray was nonspecific. Transthoracic echocardiogram revealed prominent trabeculae and spongiform appearance of the left ventricle (LV) with an ejection-fraction of 15-20%; 5 of 9 segments of the LV were trabeculated with deep intertrabecular recesses also involving the right ventricle (RV) with demonstrated blood flow in these recesses on color-doppler. The biventricular spongiform appearance was morphologically suggestive for NCM with involvement of the RV. Confirmatory cardiac MRI was performed, demonstrating excessive trabeculation of the left-ventricular apex and mid-ventricular segments. Hypertrabecularion was exhibited at the apical and lateral wall of the RV. Cardiac catheterization showed an intact cardiac vessel system. The patient was discharged on heart failure treatment and was placed on the heart transplantation list. NCM is a unique disorder resulting in serious and severe complications. The majority of the reported cases describe the involvement of the left ventricle. However, the right ventricle should be taken into careful consideration. The early diagnosis may help to increase the event-free survival.
A novel time-domain signal processing algorithm for real time ventricular fibrillation detection
NASA Astrophysics Data System (ADS)
Monte, G. E.; Scarone, N. C.; Liscovsky, P. O.; Rotter S/N, P.
2011-12-01
This paper presents an application of a novel algorithm for real time detection of ECG pathologies, especially ventricular fibrillation. It is based on segmentation and labeling process of an oversampled signal. After this treatment, analyzing sequence of segments, global signal behaviours are obtained in the same way like a human being does. The entire process can be seen as a morphological filtering after a smart data sampling. The algorithm does not require any ECG digital signal pre-processing, and the computational cost is low, so it can be embedded into the sensors for wearable and permanent applications. The proposed algorithms could be the input signal description to expert systems or to artificial intelligence software in order to detect other pathologies.
Erol, Cengiz; Koplay, Mustafa; Olcay, Ayhan; Kivrak, Ali Sami; Ozbek, Seda; Seker, Mehmet; Paksoy, Yahya
2012-11-01
Our aim was to evaluate congenital left ventricular wall abnormalities (clefts, aneurysms and diverticula), describe and illustrate imaging features, discuss terminology problems and determine their prevalence detected by cardiac CT in a single center. Coronary CT angiography images of 2093 adult patients were evaluated retrospectively in order to determine congenital left ventricular wall abnormalities. The incidence of left ventricular clefts (LVC) was 6.7% (141 patients) and statistically significant difference was not detected between the sexes regarding LVC (P=0.5). LVCs were single in 65.2% and multiple in 34.8% of patients. They were located at the basal to mid inferoseptal segment of the left ventricle in 55.4%, the basal to mid anteroseptal segment in 24.1%, basal to mid inferior segment in 17% and septal-apical septal segment in 3.5% of cases. The cleft length ranged from 5 to 22 mm (mean 10.5 mm) and they had a narrow connection with the left ventricle (mean 2.5 mm). They were contractile with the left ventricle and obliterated during systole. Congenital left ventricular septal aneurysm that was located just under the aortic valve was detected in two patients (0.1%). No case of congenital left ventricular diverticulum was detected. Cardiac CT allows us to recognize congenital left ventricular wall abnormalities which have been previously overlooked in adults. LVC is a congenital structural variant of the myocardium, is seen more frequently than previously reported and should be differentiated from aneurysm and diverticulum for possible catastrophic complications of the latter two. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Breisblatt, W M; Schulman, D S; Follansbee, W P
1991-06-01
A new miniaturized nonimaging radionuclide detector (Cardioscint, Oxford, England) was evaluated for the continuous on-line assessment of left ventricular function. This cesium iodide probe can be placed on the patient's chest and can be interfaced to an IBM compatible personal computer conveniently placed at the patient's bedside. This system can provide a beat-to-beat or gated determination of left ventricular ejection fraction and ST segment analysis. In 28 patients this miniaturized probe was correlated against a high resolution gamma camera study. Over a wide range of ejection fraction (31% to 76%) in patients with and without regional wall motion abnormalities, the correlation between the Cardioscint detector and the gamma camera was excellent (r = 0.94, SEE +/- 2.1). This detector system has high temporal (10 msec) resolution, and comparison of peak filling rate (PFR) and time to peak filling (TPFR) also showed close agreement with the gamma camera (PFR, r = 0.94, SEE +/- 0.17; TPFR, r = 0.92, SEE +/- 6.8). In 18 patients on bed rest the long-term stability of this system for measuring ejection fraction and ST segments was verified. During the monitoring period (108 +/- 28 minutes) only minor changes in ejection fraction occurred (coefficient of variation 0.035 +/- 0.016) and ST segment analysis showed no significant change from baseline. To determine whether continuous on-line measurement of ejection fraction would be useful after coronary angioplasty, 12 patients who had undergone a successful procedure were evaluated for 280 +/- 35 minutes with the Cardioscint system.(ABSTRACT TRUNCATED AT 250 WORDS)
Bybee, Kevin A; Kara, Tomas; Prasad, Abhiram; Lerman, Amir; Barsness, Greg W; Wright, R Scott; Rihal, Charanjit S
2004-12-07
The transient left ventricular apical ballooning syndrome, also known as takotsubo cardiomyopathy, is characterized by transient wall-motion abnormalities involving the left ventricular apex and mid-ventricle in the absence of obstructive epicardial coronary disease. In this paper, we review case series that report on patients with the transient left ventricular apical ballooning syndrome to better characterize patients presenting with the syndrome. We identified 7 case series that reported on at least 5 consecutive patients with the transient left ventricular apical ballooning syndrome. The syndrome more often affects postmenopausal women (82% to 100%) (mean age, 62 to 75 years). Patients commonly present with ST-segment elevation in the precordial leads, chest pain, relatively minor elevation of cardiac enzyme and biomarker levels, and transient apical systolic left ventricular dysfunction despite the absence of obstructive epicardial coronary disease. An episode of emotional or physiologic stress frequently precedes presentation with the syndrome. The in-hospital mortality rate seems to be low, as does the risk for recurrence.
Luo, Runlan; Cui, Hongyan; Huang, Dongmei; Sun, Lihua; Song, Shengda; Sun, Mengyao; Li, Guangsen
2018-06-11
Right ventricular function is a crucial factor of the prognosis of systemic lupus erythematosus (SLE). To evaluate the right ventricular function in SLE patients with different degrees of pulmonary hypertension (PH) by strain and strain rate imaging. A total of 102 SLE patients and 30 healthy volunteers were studied between October 2015 and May 2016. Patients were divided into three groups according to pulmonary artery systolic pressure (PASP) estimated by echocardiography: group control (A); PASP ≤ 30 mmHg (group B, n = 37); PASP 30-50 mmHg (mild PH; group C, n = 34); and PASP ≥ 50 mmHg (moderate-to-severe PH; group D, n = 31). Longitudinal peak systolic strain (ε) and strain rate (SR), including systolic strain rate (SRs), early diastolic strain rate (SRe) and late diastolic strain rate (SRa) were measured in the basal, middle and apical segments of the right ventricular free wall in participants by two-dimensional speckle tracking echocardiography (2D-STE) from the apical four-chamber view. A p < 0.05 was set for statistical significance. The parameters of ε, SRs, SRe, and SRa were significantly decreased in groups C and D compared with groups A and B. The ε of each segments was significantly lower in group D than in group C, while there were no differences in SRs, SRe and SRa between groups C and D. Strain and strain rate imaging could early detect the right ventricular dysfunction in SLE patients with PH, and provide important value for clinical therapy and prognosis of these patients. (Arq Bras Cardiol. 2018; [online].ahead print, PP.0-0).
Souto Bayarri, M; Masip Capdevila, L; Remuiñan Pereira, C; Suárez-Cuenca, J J; Martínez Monzonís, A; Couto Pérez, M I; Carreira Villamor, J M
2015-01-01
To compare the methods of right ventricle segmentation in the short-axis and 4-chamber planes in cardiac magnetic resonance imaging and to correlate the findings with those of the tricuspid annular plane systolic excursion (TAPSE) method in echocardiography. We used a 1.5T MRI scanner to study 26 patients with diverse cardiovascular diseases. In all MRI studies, we obtained cine-mode images from the base to the apex in both the short-axis and 4-chamber planes using steady-state free precession sequences and 6mm thick slices. In all patients, we quantified the end-diastolic volume, end-systolic volume, and the ejection fraction of the right ventricle. On the same day as the cardiac magnetic resonance imaging study, 14 patients also underwent echocardiography with TAPSE calculation of right ventricular function. No statistically significant differences were found in the volumes and function of the right ventricle calculated using the 2 segmentation methods. The correlation between the volume estimations by the two segmentation methods was excellent (r=0,95); the correlation for the ejection fraction was slightly lower (r=0,8). The correlation between the cardiac magnetic resonance imaging estimate of right ventricular ejection fraction and TAPSE was very low (r=0,2, P<.01). Both ventricular segmentation methods quantify right ventricular function adequately. The correlation with the echocardiographic method is low. Copyright © 2012 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
3D ultrasound system to investigate intraventricular hemorrhage in preterm neonates
NASA Astrophysics Data System (ADS)
Kishimoto, J.; de Ribaupierre, S.; Lee, D. S. C.; Mehta, R.; St. Lawrence, K.; Fenster, A.
2013-11-01
Intraventricular hemorrhage (IVH) is a common disorder among preterm neonates that is routinely diagnosed and monitored by 2D cranial ultrasound (US). The cerebral ventricles of patients with IVH often have a period of ventricular dilation (ventriculomegaly). This initial increase in ventricle size can either spontaneously resolve, which often shows clinically as a period of stabilization in ventricle size and eventual decline back towards a more normal size, or progressive ventricular dilation that does not stabilize and which may require interventional therapy to reduce symptoms relating to increased intracranial pressure. To improve the characterization of ventricle dilation, we developed a 3D US imaging system that can be used with a conventional clinical US scanner to image the ventricular system of preterm neonates at risk of ventriculomegaly. A motorized transducer housing was designed specifically for hand-held use inside an incubator using a transducer commonly used for cranial 2D US scans. This system was validated using geometric phantoms, US/MRI compatible ventricle volume phantoms, and patient images to determine 3D reconstruction accuracy and inter- and intra-observer volume estimation variability. 3D US geometric reconstruction was found to be accurate with an error of <0.2%. Measured volumes of a US/MRI compatible ventricle-like phantom were within 5% of gold standard water displacement measurements. Intra-class correlation for the three observers was 0.97, showing very high agreement between observers. The coefficient of variation was between 1.8-6.3% for repeated segmentations of the same patient. The minimum detectable difference was calculated to be 0.63 cm3 for a single observer. Results from ANOVA for three observers segmenting three patients of IVH grade II did not show any significant differences (p > 0.05) for the measured ventricle volumes between observers. This 3D US system can reliably produce 3D US images of the neonatal ventricular system. There is the potential to use this system to monitor the progression of ventriculomegaly over time in patients with IVH.
Hirayama, Yasutaka; Kawamura, Yuichiro; Sato, Nobuyuki; Saito, Tatsuya; Tanaka, Hideichi; Saijo, Yasuaki; Kikuchi, Kenjiro; Ohori, Katsumi; Hasebe, Naoyuki
2017-02-01
Recently, due to the detrimental effects on the ventricular function associated with right ventricular apical (RVA) pacing, right ventricular septal (RVS) pacing has become the preferred pacing method. However, the term RVS pacing refers to both right ventricular outflow-tract (RVOT) and mid-septal (RVMS) pacing, leading to a misinterpretation of the results of clinical studies. The purpose of this study, therefore, was to elucidate the functional differences of RVA, RVOT, and RVMS pacing in patients with atrioventricular block. We compared the QRS duration, global longitudinal strain (GLS), and left ventricular (LV) synchronization parameters at the three pacing sites in 47 patients. The peak systolic strain (PSS) time delay between the earliest and latest segments among the 18 LV segments and standard deviation (SD) of the time to the PSS were also calculated for the 18 LV segments at each pacing site using two-dimensional (2D) strain echocardiography. RVMS pacing was associated with a significantly shorter QRS duration compared with RVA and RVOT pacing (154.4±21.4 vs 186.5±19.9 and 171.1±21.5 ms, P <0.001). In contrast, RVOT pacing revealed a greater GLS (-14.69±4.92 vs -13.12±4.76 and -13.51±4.81%, P <0.001), shorter PSS time delay between the earliest and latest segments (236.0±87.9 vs 271.3±102.9 and 281.9±126.6%, P =0.007), and shorter SD of the time to the PSS (70.8±23.8 vs 82.7±30.8 and 81.5±33.7 ms, P =0.002) compared with RVA and RVMS pacing. These results suggest that the functional characteristics of RVOT pacing may be a more optimal pacing site than RVMS, regardless of the pacing QRS duration, in patients with atrioventricular conduction disorders.
Automatic short axis orientation of the left ventricle in 3D ultrasound recordings
NASA Astrophysics Data System (ADS)
Pedrosa, João.; Heyde, Brecht; Heeren, Laurens; Engvall, Jan; Zamorano, Jose; Papachristidis, Alexandros; Edvardsen, Thor; Claus, Piet; D'hooge, Jan
2016-04-01
The recent advent of three-dimensional echocardiography has led to an increased interest from the scientific community in left ventricle segmentation frameworks for cardiac volume and function assessment. An automatic orientation of the segmented left ventricular mesh is an important step to obtain a point-to-point correspondence between the mesh and the cardiac anatomy. Furthermore, this would allow for an automatic division of the left ventricle into the standard 17 segments and, thus, fully automatic per-segment analysis, e.g. regional strain assessment. In this work, a method for fully automatic short axis orientation of the segmented left ventricle is presented. The proposed framework aims at detecting the inferior right ventricular insertion point. 211 three-dimensional echocardiographic images were used to validate this framework by comparison to manual annotation of the inferior right ventricular insertion point. A mean unsigned error of 8, 05° +/- 18, 50° was found, whereas the mean signed error was 1, 09°. Large deviations between the manual and automatic annotations (> 30°) only occurred in 3, 79% of cases. The average computation time was 666ms in a non-optimized MATLAB environment, which potentiates real-time application. In conclusion, a successful automatic real-time method for orientation of the segmented left ventricle is proposed.
Van Nostrand, D; Janowitz, W R; Holmes, D R; Cohen, H A
1979-01-01
The ability of equilibrium gated radionuclide ventriculography to detect segmental left ventricular (LV) wall motion abnormalities was determined in 26 patients undergoing cardiac catheterization. Multiple gated studies obtained in 30 degrees right anterior oblique and 45 degrees left anterior oblique projections, played back in a movie format, were compared to the corresponding LV ventriculograms. The LV wall in the two projections was divided into eight segments. Each segment was graded as normal, hypokinetic, akinetic, dyskinetic, or indeterminate. Thirteen percent of the segments in the gated images were indeterminate; 24 out of 27 of these were proximal or distal inferior wall segments. There was exact agreement in 86% of the remaining segments. The sensitivity of the radionuclide technique for detecting normal versus any abnormal wall motion was 71%, with a specificity of 99%. Equilibrium gated ventriculography is an excellent noninvasive technique for evaluating segmental LV wall motion. It is least reliable in assessing the proximal inferior wall and interventricular septum.
Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino
2018-01-01
Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P < 0.01). Blood flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Parry, Gareth; Malbut, Katie; Dark, John H; Bexton, Rodney S
1992-01-01
Objective—To investigate the response of the transplanted heart to different pacing modes and to synchronisation of the recipient and donor atria in terms of cardiac output at rest. Design—Doppler derived cardiac output measurements at three pacing rates (90/min, 110/min and 130/min) in five pacing modes: right ventricular pacing, donor atrial pacing, recipient-donor synchronous pacing, donor atrial-ventricular sequential pacing, and synchronous recipient-donor atrial-ventricular sequential pacing. Patients—11 healthy cardiac transplant recipients with three pairs of epicardial leads inserted at transplantation. Results—Donor atrial pacing (+11% overall) and donor atrial-ventricular sequential pacing (+8% overall) were significantly better than right ventricular pacing (p < 0·001) at all pacing rates. Synchronised pacing of recipient and donor atrial segments did not confer additional benefit in either atrial or atrial-ventricular sequential modes of pacing in terms of cardiac output at rest at these fixed rates. Conclusions—Atrial pacing or atrial-ventricular sequential pacing appear to be appropriate modes in cardiac transplant recipients. Synchronisation of recipient and donor atrial segments in this study produced no additional benefit. Chronotropic competence in these patients may, however, result in improved exercise capacity and deserves further investigation. PMID:1389737
NASA Astrophysics Data System (ADS)
Reed, Judd E.; Rumberger, John A.; Buithieu, Jean; Behrenbeck, Thomas; Breen, Jerome F.; Sheedy, Patrick F., II
1995-05-01
Electron beam computed tomography is unparalleled in its ability to consistently produce high quality dynamic images of the human heart. Its use in quantification of left ventricular dynamics is well established in both clinical and research applications. However, the image analysis tools supplied with the scanners offer a limited number of analysis options. They are based on embedded computer systems which have not been significantly upgraded since the scanner was introduced over a decade ago in spite of the explosive improvements in available computer power which have occured during this period. To address these shortcomings, a workstation-based ventricular analysis system has been developed at our institution. This system, which has been in use for over five years, is based on current workstation technology and therefore has benefited from the periodic upgrades in processor performance available to these systems. The dynamic image segmentation component of this system is an interactively supervised, semi-automatic surface identification and tracking system. It characterizes the endocardial and epicardial surfaces of the left ventricle as two concentric 4D hyper-space polyhedrons. Each of these polyhedrons have nearly ten thousand vertices which are deposited into a relational database. The right ventricle is also processed in a similar manner. This database is queried by other custom components which extract ventricular function parameters such as regional ejection fraction and wall stress. The interactive tool which supervises dynamic image segmentation has been enhanced with a temporal domain display. The operator interactively chooses the spatial location of the endpoints of a line segment while the corresponding space/time image is displayed. These images, with content resembling M-Mode echocardiography, benefit form electron beam computed tomography's high spatial and contrast resolution. The segmented surfaces are displayed along with the imagery. These displays give the operator valuable feedback pertaining to the contiguity of the extracted surfaces. As with M-Mode echocardiography, the velocity of moving structures can be easily visualized and measured. However, many views inaccessible to standard transthoracic echocardiography are easily generated. These features have augmented the interpretability of cine electron beam computed tomography and have prompted the recent cloning of this system into an 'omni-directional M-Mode display' system for use in digital post-processing of echocardiographic parasternal short axis tomograms. This enhances the functional assessment in orthogonal views of the left ventricle, accounting for shape changes particularly in the asymmetric post-infarction ventricle. Conclusions: A new tool has been developed for analysis and visualization of cine electron beam computed tomography. It has been found to be very useful in verifying the consistency of myocardial surface definition with a semi-automated segmentation tool. By drawing on M-Mode echocardiography experience, electron beam tomography's interpretability has been enhanced. Use of this feature, in conjunction with the existing image processing tools, will enhance the presentations of data on regional systolic and diastolic functions to clinicians in a format that is familiar to most cardiologists. Additionally, this tool reinforces the advantages of electron beam tomography as a single imaging modality for the assessment of left and right ventricular size, shape, and regional functions.
NASA Astrophysics Data System (ADS)
Rettmann, M. E.; Lehmann, H. I.; Johnson, S. B.; Packer, D. L.
2016-03-01
Patients with ventricular arrhythmias typically exhibit myocardial scarring, which is believed to be an important anatomic substrate for reentrant circuits, thereby making these regions a key target in catheter ablation therapy. In ablation therapy, a catheter is guided into the left ventricle and radiofrequency energy is delivered into the tissue to interrupt arrhythmic electrical pathways. Low bipolar voltage regions are typically localized during the procedure through point-by-point construction of an electroanatomic map by sampling the endocardial surface with the ablation catheter and are used as a surrogate for myocardial scar. This process is time consuming, requires significant skill, and has the potential to miss low voltage sites. This has led to efforts to quantify myocardial scar preoperatively using delayed, contrast-enhanced MRI. In this paper, we evaluate the utility of left ventricular scar identification from delayed contrast enhanced magnetic resonance imaging for guidance of catheter ablation of ventricular arrhythmias. Myocardial infarcts were created in three canines followed by a delayed, contrast enhanced MRI scan and electroanatomic mapping. The left ventricle and myocardial scar is segmented from preoperative MRI images and sampled points from the procedural electroanatomical map are registered to the segmented endocardial surface. Sampled points with low bipolar voltage points visually align with the segmented scar regions. This work demonstrates the potential utility of using preoperative delayed, enhanced MRI to identify myocardial scarring for guidance of ventricular catheter ablation therapy.
Tovia-Brodie, Oholi; Belhassen, Bernard; Glick, Aharon; Shmilovich, Haim; Aviram, Galit; Rosso, Raphael; Michowitz, Yoav
2017-02-01
A new imaging software (CARTO® Segmentation Module, Biosense Webster) allows preprocedural 3-D reconstruction of all heart chambers based on cardiac CT. We describe our initial experience with the new module during ablation of ventricular arrhythmias. Eighteen consecutive patients with idiopathic ventricular arrhythmias or ischemic ventricular tachycardia (VT) were studied. In the latter group, a combined endocardial and epicardial ablation was performed. Of the 14 patients with idiopathic arrhythmias, 12 were ablated in the outflow tract (OT), 1 in the midseptal left ventricle, and 1 at the left posterior fascicular area; acute successful ablation was achieved in 11 (78.6%) patients. The procedure was discontinued due to close proximity of the arrhythmia origin to the coronary arteries (CA) in 2 patients. Acute successful uncomplicated ablation was achieved in all 4 patients with ischemic VT. During ablation in the coronary cusps commissures, the CARTO® Segmentation Module accurately defined the cusps anatomy. The precise anatomic location provided by the module assisted in successfully ablating when information from activation mapping was not optimal, by ablating at the opposite side of the cusps. In addition, by demonstrating the precise location of the CA, it allowed safe ablation of arrhythmias that originated in close proximity to the CA both in the OT area and the epicardium, eliminating the need for repeat angiography. The CARTO® Segmentation Module is useful for accurate definition of the exact anatomic location of ventricular arrhythmias and for safely ablating them especially in close proximity to the CA. © 2016 Wiley Periodicals, Inc.
Benyounes, Nadia; Lang, Sylvie; Gout, Olivier; Ancédy, Yann; Etienney, Arnaud; Cohen, Ariel
2016-10-01
Transthoracic echocardiography is the most commonly used tool for the detection of left ventricular wall motion (LVWM) abnormalities using "naked eye evaluation". This subjective and operator-dependent technique requires a high level of clinical training and experience. Two-dimensional speckle-tracking echocardiography (2D-STE), which is less operator-dependent, has been proposed for this purpose. However, the role of on-line segmental longitudinal peak systolic strain (LPSS) values in the prediction of LVWM has not been fully evaluated. To test segmental LPSS for predicting LVWM abnormalities in routine echocardiography laboratory practice. LVWM was evaluated by an experienced cardiologist, during routine practice, in 620 patients; segmental LPSS values were then calculated. In this work, reflecting real life, 99.6% of segments were successfully tracked. Mean (95% confidence interval [CI]) segmental LPSS values for normal basal (n=3409), mid (n=3468) and apical (n=3466) segments were -16.7% (-16.9% to -16.5%), -18.2% (-18.3% to -18.0%) and -21.1% (-21.3% to -20.9%), respectively. Mean (95% CI) segmental LPSS values for hypokinetic basal (n=114), mid (n=116) and apical (n=90) segments were -7.7% (-9.0% to -6.3%), -10.1% (-11.1% to -9.0%) and -9.3% (-10.5% to -8.1%), respectively. Mean (95% CI) segmental LPSS values for akinetic basal (n=128), mid (n=95) and apical (n=91) segments were -6.6% (-8.0% to -5.1%), -6.1% (-7.7% to -4.6%) and -4.2% (-5.4% to -3.0%), respectively. LPSS allowed the differentiation between normal and abnormal segments at basal, mid and apical levels. An LPSS value≥-12% detected abnormal segmental motion with a sensitivity of 78% for basal, 70% for mid and 82% for apical segments. Segmental LPSS values may help to differentiate between normal and abnormal left ventricular segments. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Zimarino, Marco; Montebello, Elena; Radico, Francesco; Gallina, Sabina; Perfetti, Matteo; Iachini Bellisarii, Francesco; Severi, Silva; Limbruno, Ugo; Emdin, Michele; De Caterina, Raffaele
2016-10-01
The exercise electrocardiographic stress test (ExET) is the most widely used non-invasive diagnostic method to detect coronary artery disease. However, the sole ST depression criteria (ST-max) have poor specificity for coronary artery disease in patients with left ventricular hypertrophy. We hypothesised that ST-segment depression/heart rate hysteresis, depicting the relative behaviour of ST segment depression during the exercise and recovery phase of the test might increase the diagnostic accuracy of ExET for coronary artery disease detection in such patients. In three cardiology centres, we studied 113 consecutive patients (mean age 66 ± 2 years; 88% men) with hypertension-related left ventricular hypertrophy at echocardiography, referred to coronary angiography after an ExET. The following ExET criteria were analysed: ST-max, chronotropic index, heart rate recovery, Duke treadmill score, ST-segment depression/heart rate hysteresis. We detected significant coronary artery disease at coronary angiography in 61 patients (53%). At receiver-operating characteristic analysis, ST-segment depression/heart rate hysteresis had the highest area under the curve value (0.75, P < 0.001 when compared with the 'neutral' receiver-operating characteristic curve value of 0.5). Area under the curve values were 0.68 (P < 0.01) for the chronotropic index, 0.58 (P = NS) for heart rate recovery, 0.57 (P = NS) for ST-max and 0.52 (P = NS) for the Duke treadmill score. Among currently available ExET diagnostic variables, ST-segment depression/heart rate hysteresis offers a substantially better diagnostic accuracy for coronary artery disease than conventional criteria in patients with hypertension-related left ventricular hypertrophy. © The European Society of Cardiology 2016.
Stylus/tablet user input device for MRI heart wall segmentation: efficiency and ease of use.
Taslakian, Bedros; Pires, Antonio; Halpern, Dan; Babb, James S; Axel, Leon
2018-05-02
To determine whether use of a stylus user input device (UID) would be superior to a mouse for CMR segmentation. Twenty-five consecutive clinical cardiac magnetic resonance (CMR) examinations were selected. Image analysis was independently performed by four observers. Manual tracing of left (LV) and right (RV) ventricular endocardial contours was performed twice in 10 randomly assigned sessions, each session using only one UID. Segmentation time and the ventricular function variables were recorded. The mean segmentation time and time reduction were calculated for each method. Intraclass correlation coefficients (ICC) and Bland-Altman plots of function variables were used to assess intra- and interobserver variability and agreement between methods. Observers completed a Likert-type questionnaire. The mean segmentation time (in seconds) was significantly less with the stylus compared to the mouse, averaging 206±108 versus 308±125 (p<0.001) and 225±140 versus 353±162 (p<0.001) for LV and RV segmentation, respectively. The intra- and interobserver agreement rates were excellent (ICC≥0.75) regardless of the UID. There was an excellent agreement between measurements derived from manual segmentation using different UIDs (ICC≥0.75), with few exceptions. Observers preferred the stylus. The study shows a significant reduction in segmentation time using the stylus, a subjective preference, and excellent agreement between the methods. • Using a stylus for MRI ventricular segmentation is faster compared to mouse • A stylus is easier to use and results in less fatigue • There is excellent agreement between stylus and mouse UIDs.
NASA Astrophysics Data System (ADS)
Atehortúa, Angélica; Zuluaga, Maria A.; Ourselin, Sébastien; Giraldo, Diana; Romero, Eduardo
2016-03-01
An accurate ventricular function quantification is important to support evaluation, diagnosis and prognosis of several cardiac pathologies. However, expert heart delineation, specifically for the right ventricle, is a time consuming task with high inter-and-intra observer variability. A fully automatic 3D+time heart segmentation framework is herein proposed for short-axis-cardiac MRI sequences. This approach estimates the heart using exclusively information from the sequence itself without tuning any parameters. The proposed framework uses a coarse-to-fine approach, which starts by localizing the heart via spatio-temporal analysis, followed by a segmentation of the basal heart that is then propagated to the apex by using a non-rigid-registration strategy. The obtained volume is then refined by estimating the ventricular muscle by locally searching a prior endocardium- pericardium intensity pattern. The proposed framework was applied to 48 patients datasets supplied by the organizers of the MICCAI 2012 Right Ventricle segmentation challenge. Results show the robustness, efficiency and competitiveness of the proposed method both in terms of accuracy and computational load.
21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).
Code of Federal Regulations, 2011 CFR
2011-04-01
... a visible or audible signal or alarm when atrial or ventricular arrhythmia, such as premature contraction or ventricular fibrillation, occurs. (b) Classification. Class II (special controls). The guidance...
21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).
Code of Federal Regulations, 2010 CFR
2010-04-01
... a visible or audible signal or alarm when atrial or ventricular arrhythmia, such as premature contraction or ventricular fibrillation, occurs. (b) Classification. Class II (special controls). The guidance...
Tulevski, Igor I; Zijta, Frank M; Smeijers, Anika S; Dodge-Khatami, Ali; van der Wall, Ernst E; Mulder, Barbara J M
2004-04-01
Patients with congenitally corrected transposition are at risk of right ventricular dysfunction and failure. With this in mind, we examined 13 patients with congenitally corrected transposition, 7 not having undergone surgery, and 6 after physiological repair, comparing them with 6 healthy subjects matched for age and sex, using cardiac magnetic resonance imaging, at rest and during dobutamine stress, in order to determine regional and global right ventricular response to stress. At rest, the patients had significantly decreased overall wall motion compared to their healthy peers (7.2 +/- 0.5, versus 9.8 +/- 0.4 mm). During infusion of dobutamine, overall wall motion increased to 12.8 +/- 0.4 mm in the healthy subjects, versus 8.8 +/- 1.0 mm in patients. At the regional level, significant differences in mural motion were found between patients and controls in the anterior (9.5 +/- 1.1, versus 13.2 +/- 0.6 mm), posterior (10.2 +/- 1.6, versus 13.2 +/- 0.8 mm), and septal segments (5.0 +/- 0.8, versus 11.2 +/- 0.6 mm). At rest, overall mural thickening in patients was similar to that of controls, but significantly less in patients during stress. During dobutamine stress, patients showed significantly less regional wall thickening than controls, particularly in the septal (2.7 +/- 0.6, versus 6.0 +/- 0.4 mm, respectively) and in the anterior segments (4.2 +/- 0.6, versus 7.8 +/- 0.6 mm, respectively). Right ventricular ejection fraction strongly correlated with mural motion and thickening, both at rest and during stress. Abnormal regional function in the systemic morphologically right ventricle may occur in patients with congenitally corrected transposition, which strongly correlates with right ventricular ejection fraction. Our findings support the hypothesis that, in patients with congenitally corrected transposition, ischemia of the right ventricular myocardium contributes to the development of right ventricular dysfunction.
Haeck, Joost D E; Verouden, Niels J W; Kuijt, Wichert J; Koch, Karel T; Van Straalen, Jan P; Fischer, Johan; Groenink, Maarten; Bilodeau, Luc; Tijssen, Jan G P; Krucoff, Mitchell W; De Winter, Robbert J
2010-04-15
The purpose of the present study was to determine the prognostic value of N-terminal pro-brain natriuretic peptide (NT-pro-BNP), among other serum biomarkers, on cardiac magnetic resonance (CMR) imaging parameters of cardiac function and infarct size in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. We measured NT-pro-BNP, cardiac troponin T, creatinine kinase-MB fraction, high-sensitivity C-reactive protein, and creatinine on the patients' arrival at the catheterization laboratory in 206 patients with ST-segment elevation myocardial infarction. The NT-pro-BNP levels were divided into quartiles and correlated with left ventricular function and infarct size measured by CMR imaging at 4 to 6 months. Compared to the lower quartiles, patients with nonanterior wall myocardial infarction in the highest quartile of NT-pro-BNP (> or = 260 pg/ml) more often had a greater left ventricular end-systolic volume (68 vs 39 ml/m(2), p <0.001), a lower left ventricular ejection fraction (42% vs 54%, p <0.001), a larger infarct size (9 vs 4 g/m(2), p = 0.002), and a larger number of transmural segments (11% of segments vs 3% of segments, p <0.001). Multivariate analysis revealed that a NT-pro-BNP level of > or = 260 pg/ml was the strongest independent predictor of left ventricular ejection fraction in patients with nonanterior wall myocardial infarction compared to the other serum biomarkers (beta = -5.8; p = 0.019). In conclusion, in patients with nonanterior wall myocardial infarction undergoing primary percutaneous coronary intervention, an admission NT-pro-BNP level of > or = 260 pg/ml was a strong, independent predictor of left ventricular function assessed by CMR imaging at follow-up. Our findings suggest that NT-pro-BNP, a widely available biomarker, might be helpful in the early risk stratification of patients with nonanterior wall myocardial infarction. Copyright 2010 Elsevier Inc. All rights reserved.
Forsha, Daniel; Risum, Niels; Smith, P Brian; Kanter, Ronald J; Samad, Zainab; Barker, Piers; Kisslo, Joseph
2016-11-01
Patients with systemic right ventricles frequently experience progressive heart failure and conduction abnormalities leading to abnormal ventricular activation. Activation delay-induced mechanical dyssynchrony can contribute to ventricular failure and is identified by a classic strain pattern of paradoxical opposing wall motion that is an excellent predictor of response to cardiac resynchronization therapy in adults with left bundle branch block. The specific aims of this study were to compare right ventricular (RV) mechanics in an adult systemic right ventricle population versus control subjects, evaluate the feasibility of this RV strain pattern analysis, and determine the frequency of the classic pattern. Young adults (n = 25) with d-transposition of the great arteries, status post Mustard or Senning palliation (TGA-MS), were ambispectively enrolled and compared with healthy young adults (n = 30) who were prospectively enrolled. All subjects were imaged using novel three-apical view (18-segment) RV longitudinal speckle-tracking strain analysis (EchoPAC) and electrocardiographic data. Patients with TGA-MS had diminished RV global peak systolic strain compared with control subjects (-12.0 ± 4.0% vs -23.3 ± 2.3%, P < .001). Most patients with TGA-MS had intrinsic or left ventricular paced right bundle branch block. A classic pattern was present in 11 of 25 subjects (44%), but this pattern would have been missed in four of 11 based only on the RV four-chamber (six-segment) model. Only three subjects underwent cardiac resynchronization therapy. Both subjects who had the classic pattern responded to cardiac resynchronization therapy, whereas the one nonresponder did not have the classic pattern. Systemic right ventricles demonstrated decreased function and increased mechanical dyssynchrony. The classic pattern of activation delay-induced mechanical dyssynchrony was frequently seen in this TGA-MS population and associated with activation delays. This comprehensive RV approach demonstrated incremental value. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Automatic right ventricle (RV) segmentation by propagating a basal spatio-temporal characterization
NASA Astrophysics Data System (ADS)
Atehortúa, Angélica; Zuluaga, María. A.; Martínez, Fabio; Romero, Eduardo
2015-12-01
An accurate right ventricular (RV) function quantification is important to support the evaluation, diagnosis and prognosis of several cardiac pathologies and to complement the left ventricular function assessment. However, expert RV delineation is a time consuming task with high inter-and-intra observer variability. In this paper we present an automatic segmentation method of the RV in MR-cardiac sequences. Unlike atlas or multi-atlas methods, this approach estimates the RV using exclusively information from the sequence itself. For so doing, a spatio-temporal analysis segments the heart at the basal slice, segmentation that is then propagated to the apex by using a non-rigid-registration strategy. The proposed approach achieves an average Dice Score of 0:79 evaluated with a set of 48 patients.
Speckle tracking evaluation of right ventricular functions in children with sickle cell disease.
Tolba, Osama Abd Rab Elrasol; El-Shanshory, Mohamed Ramadan; El-Gamasy, Mohamed Abd Elaziz; El-Shehaby, Walid Ahmed
2017-01-01
Cardiac dysfunction is a risk factor for death in patients with sickle cell disease (SCD). Aim of the work is to evaluate the right ventricular systolic and diastolic functions by tissue Doppler and speckling tracking imaging in children with SCD. Thirty children with SCD and thirty controls were subjected to clinical, laboratory evaluations, and echocardiographic study using GE Vivid 7 (GE Medical System, Horten, Norway with a 3.5-MHz multifrequency transducer) including; Two-dimensional and tissue Doppler echocardiographic study (lateral tricuspid valve annulus peak E' velocity, lateral tricuspid valve annulus peak A' velocity, E'/A' ratio, isovolumetric relaxation time, lateral tricuspid valve annulus S' and septal S' waves and peak longitudinal systolic strain [PLSS] and time to PLSS) were done in six right ventricular segments. There was a significant decrease in right ventricular systolic and diastolic function in patients group when compared to controls. Children with SCD have impaired right ventricular systolic and diastolic functions when compared to healthy children with early evaluation of the systolic dysfunction by speckle tracking imaging technique.
Oghli, Mostafa Ghelich; Dehlaghi, Vahab; Zadeh, Ali Mohammad; Fallahi, Alireza; Pooyan, Mohammad
2014-07-01
Assessment of cardiac right-ventricle functions plays an essential role in diagnosis of arrhythmogenic right ventricular dysplasia (ARVD). Among clinical tests, cardiac magnetic resonance imaging (MRI) is now becoming the most valid imaging technique to diagnose ARVD. Fatty infiltration of the right ventricular free wall can be visible on cardiac MRI. Finding right-ventricle functional parameters from cardiac MRI images contains segmentation of right-ventricle in each slice of end diastole and end systole phases of cardiac cycle and calculation of end diastolic and end systolic volume and furthermore other functional parameters. The main problem of this task is the segmentation part. We used a robust method based on deformable model that uses shape information for segmentation of right-ventricle in short axis MRI images. After segmentation of right-ventricle from base to apex in end diastole and end systole phases of cardiac cycle, volume of right-ventricle in these phases calculated and then, ejection fraction calculated. We performed a quantitative evaluation of clinical cardiac parameters derived from the automatic segmentation by comparison against a manual delineation of the ventricles. The manually and automatically determined quantitative clinical parameters were statistically compared by means of linear regression. This fits a line to the data such that the root-mean-square error (RMSE) of the residuals is minimized. The results show low RMSE for Right Ventricle Ejection Fraction and Volume (≤ 0.06 for RV EF, and ≤ 10 mL for RV volume). Evaluation of segmentation results is also done by means of four statistical measures including sensitivity, specificity, similarity index and Jaccard index. The average value of similarity index is 86.87%. The Jaccard index mean value is 83.85% which shows a good accuracy of segmentation. The average of sensitivity is 93.9% and mean value of the specificity is 89.45%. These results show the reliability of proposed method in these cases that manual segmentation is inapplicable. Huge shape variety of right-ventricle led us to use a shape prior based method and this work can develop by four-dimensional processing for determining the first ventricular slices.
Garson, Christopher D; Li, Bing; Acton, Scott T; Hossack, John A
2008-06-01
The active surface technique using gradient vector flow allows semi-automated segmentation of ventricular borders. The accuracy of the algorithm depends on the optimal selection of several key parameters. We investigated the use of conservation of myocardial volume for quantitative assessment of each of these parameters using synthetic and in vivo data. We predicted that for a given set of model parameters, strong conservation of volume would correlate with accurate segmentation. The metric was most useful when applied to the gradient vector field weighting and temporal step-size parameters, but less effective in guiding an optimal choice of the active surface tension and rigidity parameters.
Separham, Ahmad; Ghaffari, Samad; Sohrabi, Bahram; Aslanabadi, Naser; Hadavi Bavil, Mozhgan; Lotfollahi, Hasanali
2017-01-01
Low level of testosterone may be associated with cardiovascular diseases in men, as some evidence suggests a protective role for testosterone in cardiovascular system. Little is known about the possible role of serum testosterone in response to reperfusion therapy in ST-elevation myocardial infarction (STEMI) and its relationship with ST-segment recovery. The present study was conducted to evaluate the association of serum testosterone levels with ST-segment resolution following primary percutaneous coronary intervention (PPCI) in male patients with acute STEMI. Forty-eight men (mean age 54.55 ± 12.20) with STEMI undergoing PPCI were enrolled prospectively. Single-lead ST segment resolution in the lead with maximum baseline ST-elevation was measured and patients were divided into two groups according to the degree of ST-segment resolution: complete (> or =50%) or incomplete (<50%). The basic and demographic data of all patients, their left ventricular ejection fraction (LVEF) and laboratory findings including serum levels of free testosterone and cardiac enzymes were recorded along with angiographic finding and baseline TIMI (Thrombolysis in Myocardial Infarction) flow and also in-hospital complications and then these variables were compared between two groups. A complete ST-resolution (≥50%) was observed in 72.9% of the patients. The serum levels of free testosterone ( P = 0.04), peak cardiac troponin ( P = 0.03) were significantly higher and hs-CRP ( P = 0.02) were lower in patients with complete ST-resolution compared to those with incomplete ST-resolution. In-hospital complications were observed in 31.2% of patients. The patients with a lower baseline TIMI flow ( P = 0.03) and those who developed complications ( P = 0.04) had lower levels of free testosterone. A significant positive correlation was observed between the left ventricular function and serum levels of free testosterone ( P = 0.01 and r = +0.362). This study suggests that in men with STEMI undergoing PPCI, higher serum levels of testosterone are associated with a better reperfusion response, fewer complications and a better left ventricular function.
Assessment of mechanical ventricular synchrony in Doberman Pinschers with dilated cardiomyopathy.
López-Alvarez, Jordi; Fonfara, Sonja; Pedro, Brigite; Stephenson, Hannah; Cripps, Peter J; Dukes-McEwan, Joanna
2011-09-01
Loss of temporal synchrony of myocardial contraction has been shown to reduce systolic function and be responsible for disease progression in people. The objective of this study is the assessment of inter- and intra ventricular synchrony in healthy Doberman Pinschers and those with dilated cardiomyopathy (DCM) by use of conventional Doppler and tissue velocity imaging. A total of 60 scans from 35 client-owned Doberman Pinschers presented for cardiac evaluation were analysed. Retrospective analysis of data. Using the European Society of Veterinary Cardiology DCM taskforce scoring system, Doberman Pinschers were classified into 4 groups: Control (Group 1; n=12), depressed systolic function other than DCM (Group 2; n=9), preclinical DCM (Group 3; n=8) and symptomatic DCM (Group 4; n=6). The time intervals between the beginning of the QRS complex and the peak velocity of pulmonic flow (Q-P) and the peak aortic flow (Q-Ao) were used to assess global synchrony between both ventricles. The time intervals between the beginning of the QRS complex and the peak myocardial systolic velocity (Q-peak S) and the onset of myocardial systolic velocity (Q-start S) were measured at the base of the right and left ventricular free wall (RVFW and LVFW) and interventricular septum (IVS), and used to determine segmental longitudinal inter- and intra ventricular synchrony. No significant loss of global or segmental longitudinal inter- or intra ventricular synchrony was identified between the groups. Impairment of longitudinal fibre synchrony does not appear to be significantly associated with clinical status of DCM in Doberman Pinschers, although it was identified in certain individuals. Copyright © 2011 Elsevier B.V. All rights reserved.
Hirano, Yutaka; Ikuta, Shin-Ichiro; Nakano, Manabu; Akiyama, Seita; Nakamura, Hajime; Nasu, Masataka; Saito, Futoshi; Nakagawa, Junichi; Matsuzaki, Masashi; Miyazaki, Shunichi
2007-02-01
Assessment of deterioration of regional wall motion by echocardiography is not only subjective but also features difficulties with interobserver agreement. Progress in digital communication technology has made it possible to send video images from a distant location via the Internet. The possibility of evaluating left ventricular wall motion using video images sent via the Internet to distant institutions was evaluated. Twenty-two subjects were randomly selected. Four sets of video images (parasternal long-axis view, parasternal short-axis view, apical four-chamber view, and apical two-chamber view) were taken for one cardiac cycle. The images were sent via the Internet to two institutions (observer C in facility A and observers D and E in facility B) for evaluation. Great care was taken to prevent disclosure of patient information to these observers. Parasternal long-axis images were divided into four segments, and the parasternal short-axis view, apical four-chamber view, and apical two-chamber view were divided into six segments. One of the following assessments, normokinesis, hypokinesis, akinesis, or dyskinesis, was assigned to each segment. The interobserver rates of agreement in judgments between observers C and D, observers C and E, and intraobserver agreement rate (for observer D) were calculated. The rate of interobserver agreement was 85.7% (394/460 segments; Kappa = 0.65) between observers C and D, 76.7% (353/460 segments; Kappa = 0.39) between observers D and E, and 76.3% (351/460 segments; Kappa = 0.36)between observers C and E, and intraobserver agreement was 94.3% (434/460; Kappa = 0.86). Segments of difference judgments between observers C and D were normokinesis-hypokinesis; 62.1%, hypokinesis-akinesis; 33.3%, akinesis-dyskinesis; 3.0%, and normokinesis-akinesis; 1.5%. Wall motion can be evaluated at remote institutions via the Internet.
Candell-Riera, Jaume; Romero-Farina, Guillermo; Milá, Marta; Aguadé-Bruix, Santiago
2008-10-01
The objective of this study was to use low-dose dobutamine (LDD) gated single-photon emission computed tomography (SPECT) to evaluate segmental thickening of the left ventricle (LV) and its relationship with changes in ejection fraction (EF) and ventricular volumes in patients with ischemic cardiomyopathy. This prospective multicenter study involved 89 patients with ischemic cardiomyopathy (i.e., EF < or =40%) who underwent LDD gated-SPECT at rest. The LV was divided into 17 segments and systolic thickening was assessed in a total of 1513 segments during LDD infusion. RESULTS; A significant increase in LVEF (33.2% vs. 30.8%; P< .001) was observed during LDD infusion and occurred at the expense of a reduction in end-systolic volume (130.5 mL vs. 136.4 mL; P=.005). The increase in EF was > or =5% in 33.7% of patients, while the EF decreased by > or =5% in 5.6% of patients. With LDD infusion, both an improvement in > or =3 segments with severely decreased baseline thickening (odds ratio [OR] = 18.3; 95% confidence interval [CI], 5.3-63) and an improvement in > or =10 segments with mild-to-moderate alterations in baseline thickening (OR = 4.53; 95% CI, 1.26-16.16) were associated with a > or =5% increase in LVEF. During the assessment of global left ventricular contractile reserve by LDD gated-SPECT, attention should be paid not only to the behavior of segments with severely decreased baseline thickening, which are generally regarded as indicating viability, but also to segments with mild-to-moderate alterations and to those in which thickening decreases.
Juliani, Paulo Sérgio; Costa, Eder França da; Correia, Aristides Tadeu; Monteiro, Rosangela; Jatene, Fabio Biscegli
2014-01-01
A feature of dilated cardiomyopathy is the deformation of ventricular cavity, which contributes to systolic dysfunction. Few studies have evaluated this deformation bearing in mind ventricular regions and segments of the ventricle, which could reveal important details of the remodeling process, supporting a better understanding of its role in functional impairment and the development of new therapeutic strategies. To evaluate if, in basal, equatorial and apical regions, increased internal transverse perimeter of left ventricle in idiopathic dilated cardiomyopathy occurs proportionally between the septal and non-septal segment. We performed an anatomical study with 28 adult hearts from human cadavers. One group consisted of 18 hearts with idiopathic dilated cardiomyopathy and another group with 10 normal hearts. After lamination and left ventricle digital image capture, in three different regions (base, equator and apex), the transversal internal perimeter of left ventricle was divided into two segments: septal and not septal. These segments were measured by proper software. It was established an index of proportionality between these segments, called septal and non-septal segment index. Then we determined whether this index was the same in both groups. Among patients with normal hearts and idiopathic dilated cardiomyopathy, the index of proportionality between the two segments (septal and non-septal) showed no significant difference in the three regions analyzed. The comparison results of the indices NSS/SS among normal and enlarged hearts were respectively: in base 1.99 versus 1.86 (P=0.46), in equator 2.22 versus 2.18 (P=0.79) and in apex 2.96 versus 3.56 (P=0.11). In the idiopathic dilated cardiomyopathy, the transversal dilatation of left ventricular internal perimeter occurs proportionally between the segments corresponding to the septum and free wall at the basal, equatorial and apical regions of this chamber.
Perugini, E; Rapezzi, C; Piva, T; Leone, O; Bacchi‐Reggiani, L; Riva, L; Salvi, F; Lovato, L; Branzi, A; Fattori, R
2006-01-01
Objective To investigate the prevalence and distribution of gadolinium (Gd) enhancement at cardiac magnetic resonance (CMR) imaging in patients with cardiac amyloidosis (CA) and to look for associations with clinical, morphological, and functional features. Patients and design 21 patients with definitely diagnosed CA (nine with immunoglobulin light chain amyloidosis and 12 transthyretin related) underwent Gd‐CMR. Results Gd enhancement was detected in 16 of 21 (76%) patients. Sixty six of 357 (18%) segments were enhanced, more often at the mid ventricular level. Transmural extension of enhancement within each patient significantly correlated with left ventricular (LV) end systolic volume (r = 0.58). The number of enhanced segments correlated with LV end diastolic volume (r = 0.76), end systolic volume (r = 0.6), and left atrial size (r = 0.56). Segments with > 50% extensive transmural enhancement more often were severely hypokinetic or akinetic (p = 0.001). Patients with > 2 enhanced segments had significantly lower 12 lead QRS voltage and Sokolow‐Lyon index. No relation was apparent with any other clinical, morphological, functional, or histological characteristics. Conclusion Gd enhancement is common but not universally present in CA, probably due to expansion of infiltrated interstitium. The segmental and transmural distribution of the enhancement is highly variable, and mid‐ventricular regions are more often involved. Enhancement appears to be associated with impaired segmental and global contractility and a larger atrium. PMID:15939726
2011-01-01
Background Cardiovascular magnetic resonance (CMR) with late gadolinium enhancement (LGE) can provide unique data on the transmural extent of scar/viability. We assessed the prevalence of dysfunctional myocardium, including partial thickness scar, which could contribute to left ventricular contractile dysfunction in patients with heart failure and ischaemic heart disease who denied angina symptoms. Methods We invited patients with ischaemic heart disease and a left ventricular ejection fraction < 50% by echocardiography to have LGE CMR. Myocardial contractility and transmural extent of scar were assessed using a 17-segment model. Results The median age of the 193 patients enrolled was 70 (interquartile range: 63-76) years and 167 (87%) were men. Of 3281 myocardial segments assessed, 1759 (54%) were dysfunctional, of which 581 (33%) showed no scar, 623 (35%) had scar affecting ≤50% of wall thickness and 555 (32%) had scar affecting > 50% of wall thickness. Of 1522 segments with normal contractile function, only 98 (6%) had evidence of scar on CMR. Overall, 182 (94%) patients had ≥1 and 107 (55%) patients had ≥5 segments with contractile dysfunction that had no scar or ≤50% transmural scar suggesting viability. Conclusions In this cohort of patients with left ventricular systolic dysfunction and ischaemic heart disease, about half of all segments had contractile dysfunction but only one third of these had > 50% of the wall thickness affected by scar, suggesting that most dysfunctional segments could improve in response to an appropriate intervention. PMID:21936915
ECG signal analysis through hidden Markov models.
Andreão, Rodrigo V; Dorizzi, Bernadette; Boudy, Jérôme
2006-08-01
This paper presents an original hidden Markov model (HMM) approach for online beat segmentation and classification of electrocardiograms. The HMM framework has been visited because of its ability of beat detection, segmentation and classification, highly suitable to the electrocardiogram (ECG) problem. Our approach addresses a large panel of topics some of them never studied before in other HMM related works: waveforms modeling, multichannel beat segmentation and classification, and unsupervised adaptation to the patient's ECG. The performance was evaluated on the two-channel QT database in terms of waveform segmentation precision, beat detection and classification. Our waveform segmentation results compare favorably to other systems in the literature. We also obtained high beat detection performance with sensitivity of 99.79% and a positive predictivity of 99.96%, using a test set of 59 recordings. Moreover, premature ventricular contraction beats were detected using an original classification strategy. The results obtained validate our approach for real world application.
A novel cardiac MR chamber volume model for mechanical dyssynchrony assessment
NASA Astrophysics Data System (ADS)
Song, Ting; Fung, Maggie; Stainsby, Jeffrey A.; Hood, Maureen N.; Ho, Vincent B.
2009-02-01
A novel cardiac chamber volume model is proposed for the assessment of left ventricular mechanical dyssynchrony. The tool is potentially useful for assessment of regional cardiac function and identification of mechanical dyssynchrony on MRI. Dyssynchrony results typically from a contraction delay between one or more individual left ventricular segments, which in turn leads to inefficient ventricular function and ultimately heart failure. Cardiac resynchronization therapy has emerged as an electrical treatment of choice for heart failure patients with dyssynchrony. Prior MRI techniques have relied on assessments of actual cardiac wall changes either using standard cine MR images or specialized pulse sequences. In this abstract, we detail a semi-automated method that evaluates dyssynchrony based on segmental volumetric analysis of the left ventricular (LV) chamber as illustrated on standard cine MR images. Twelve sectors each were chosen for the basal and mid-ventricular slices and 8 sectors were chosen for apical slices for a total of 32 sectors. For each slice (i.e. basal, mid and apical), a systolic dyssynchrony index (SDI) was measured. SDI, a parameter used for 3D echocardiographic analysis of dyssynchrony, was defined as the corrected standard deviation of the time at which minimal volume is reached in each sector. The SDI measurement of a healthy volunteer was 3.54%. In a patient with acute myocardial infarction, the SDI measurements 10.98%, 16.57% and 1.41% for basal, mid-ventricular and apical LV slices, respectively. Based on published 3D echocardiogram reference threshold values, the patient's SDI corresponds to moderate basal dysfunction, severe mid-ventricular dysfunction, and normal apical LV function, which were confirmed on echocardiography. The LV chamber segmental volume analysis model and SDI is feasible using standard cine MR data and may provide more reliable assessment of patients with dyssynchrony especially if the LV myocardium is thin or if the MR images have spatial resolution insufficient for proper resolution of wall thickness-features problematic for dyssynchrony assessment using existing MR techniques.
[Evaluation of echocardiography for determining left ventricular function].
Wu, H; Zhu, W; Xu, J
1994-02-01
Left ventricular ejection fraction (LVEF) was calculated by echocardiography and gate blood pool (GBP) in 33 patients including those with coronary heart disease, acute and old myocardiac infarction, cardiomyopathy or mitral prolapse. Fourteen of the 33 had segmental wall motion abnormalities and 19 had non-segmental wall motion abnormalities. The results of comparing echocardiography and GBP showed that the former could substitute for other invasive and expensive examinations to determine LVEF (r = 0.804-0.964 in the 5 echocardiography methods used). Mod-Simpsons method of cross-sectioned echocardiography was the most accurate echocardiographic method (r = 0.964, sensitivity 90.9%) in all patients. The Teich method of M-mode echocardiography was useful in patients who had non-segmental wall motion abnormalities only (r = 0.957, sensitivity 94.7%) but not in patients who had segmental wall motion abnormalities (r = 0.703, sensitivity 42.9%).
Reindl, Martin; Feistritzer, Hans-Josef; Reinstadler, Sebastian Johannes; Mueller, Lukas; Tiller, Christina; Brenner, Christoph; Mayr, Agnes; Henninger, Benjamin; Mair, Johannes; Klug, Gert; Metzler, Bernhard
2018-04-01
Adverse left ventricular remodeling is one of the major determinants of heart failure and mortality in patients surviving ST-segment elevation myocardial infarction (STEMI). The hypothalamic-pituitary-thyroid axis is a key cardiovascular regulator; however, the relationship between hypothalamic-pituitary-thyroid status and post-STEMI left ventricular remodeling is unclear. We aimed to investigate the association between thyroid-stimulating hormone concentrations and the development of left ventricular remodeling following reperfused STEMI. In this prospective observational study of 102 consecutive STEMI patients, thyroid-stimulating hormone levels were measured at the first day after infarction and 4 months thereafter. Cardiac magnetic resonance scans were performed within the first week as well as at 4 months follow-up to determine infarct characteristics, myocardial function and as primary endpoint left ventricular remodeling, defined as a 20% or greater increase in left ventricular end-diastolic volume. Patients with left ventricular remodeling ( n=15, 15%) showed significantly lower concentrations of baseline (1.20 [0.92-1.91] vs. 1.73 [1.30-2.60] mU/l; P=0.02) and follow-up (1.11 [0.86-1.28] vs. 1.51 [1.15-2.02] mU/l; P=0.002) thyroid-stimulating hormone. The association between baseline thyroid-stimulating hormone and left ventricular remodeling remained significant after adjustment for major clinical (peak high-sensitivity cardiac troponin T and C-reactive protein, heart rate; odds ratio (OR) 5.33, 95% confidence interval (CI) 1.52-18.63; P=0.01) and cardiac magnetic resonance predictors of left ventricular remodeling (infarct size, microvascular obstruction, ejection fraction; OR 4.59, 95% CI 1.36-15.55; P=0.01). Furthermore, chronic thyroid-stimulating hormone was related to left ventricular remodeling independently of chronic left ventricular remodeling correlates (infarct size, ejection fraction, left ventricular end-diastolic volume, left ventricular end-systolic volume; OR 9.22, 95% CI 1.69-50.22; P=0.01). Baseline and chronic thyroid-stimulating hormone concentrations following STEMI were independently associated with left ventricular remodeling, proposing a novel pathophysiological axis in the development of post-STEMI left ventricular remodeling.
Miranda, Berta; Barrabés, José A; Figueras, Jaume; Pineda, Victor; Rodríguez-Palomares, José; Lidón, Rosa-Maria; Sambola, Antonia; Bañeras, Jordi; Otaegui, Imanol; García-Dorado, David
2016-01-01
Bilirubin may elicit cardiovascular protection and heme oxygenase-1 overexpression attenuated post-infarction ventricular remodeling in experimental animals, but the association between bilirubin levels and post-infarction remodeling is unknown. In 145 patients with a first anterior ST-segment elevation acute myocardial infarction (STEMI), we assessed whether plasma bilirubin on admission predicted adverse remodeling (left ventricular end-diastolic volume [LVEDV] increase ≥20% between discharge and 6 months, estimated by magnetic resonance imaging). Patients' baseline characteristics and management were comparable among bilirubin tertiles. LVEDV increased at 6 months (P < 0.001) with respect to the initial exam, but the magnitude of this increase was similar across increasing bilirubin tertiles (10.8 [30.2], 10.1 [22.9], and 12.7 [24.3]%, P = 0.500). Median (25-75 percentile) bilirubin values in patients with and without adverse remodeling were 0.75 (0.60-0.93) and 0.73 (0.60-0.92) mg/dL (P = 0.693). Absence of final TIMI flow grade 3 (odds ratio 3.92, 95% CI 1.12-13.66) and a history of hypertension (2.04, 0.93-4.50), but not admission bilirubin, were independently associated with adverse remodeling. Bilirubin also did not predict the increase in ejection fraction at 6 months. Admission bilirubin values are not related to LVEDV or ejection fraction progression after a first anterior STEMI and do not predict adverse ventricular remodeling. Key messages Bilirubin levels are inversely related to cardiovascular disease, and overexpression of heme oxygenase-1 (the enzyme that determines bilirubin production) has prevented post-infarction ventricular remodeling in experimental animals, but the association between bilirubin levels and the progression of ventricular volumes and function in patients with acute myocardial infarction remained unexplored. In this cohort of patients with a first acute anterior ST-segment elevation myocardial infarction receiving contemporary management, bilirubin levels on admission were not predictive of the changes in left ventricular volumes or ejection fraction at 6 months measured by serial cardiac magnetic resonance imaging. The data are contrary to a significant protective effect of bilirubin against post-infarction ventricular remodeling.
Jouve, R; Puddu, P E; Langlet, F; Lanti, M; Guillen, J C; Rolland, P H; Serradimigni, A
1988-01-01
Multivariate analysis of survival using Cox's proportional hazards model demonstrates that several clinically measurable covariates are determinants of life-threatening arrhythmias following left circumflex coronary artery occlusion-reperfusion in 107 dogs. These are heart rate, ST segment elevation and mean aortic pressure immediately (3 min) following occlusion, and the presence of early (0-10 min) post-occlusion sustained ventricular tachycardia. The risk of occlusion-reperfusion ventricular fibrillation was determined according to Cox's solution based on ST segment elevation, thus enabling quantification of the role of cicletanine. Since cicletanine-treated dogs had reduced mean ST segment elevation at 3 min post-occlusion, lower incidence of early post-occlusion (0-10 min) sustained ventricular tachycardia, and increased endogenous production of prostacyclin, and the latter was inversely correlated with the level of ST segment elevation, it is concluded that such favourable effects on the ischaemic myocardium were contributory to the improved outcome in these experiments. These effects on the ischaemic myocardium obtained in spite of a hypotensive action in the experimental setting might be regarded as desirable and it is therefore suggested that they should be further investigated by pharmacodynamic studies in human subjects.
Castelvecchio, Serenella; Careri, Giulia; Ambrogi, Federico; Camporeale, Antonia; Menicanti, Lorenzo; Secchi, Francesco; Lombardi, Massimo
2018-01-01
Post-infarction myocardial scar causes adverse left ventricular remodelling and negatively affects the prognosis. We sought to investigate whether scar extent and location obtained by cardiac magnetic resonance may affect the reverse remodelling and survival of heart failure patients undergoing surgical ventricular reconstruction. From January 2011 to December 2015, 151 consecutive patients with previous myocardial infarction and left ventricular remodelling underwent surgical ventricular reconstruction at our Institution, of which 88 (58%) patients had a preoperative protocol-standardized late gadolinium enhancement (LGE)-cardiac magnetic resonance examination during the week before surgery. We excluded 40 patients with devices (26%), 15 patients with irregular heart rhythm (permanent atrial fibrillation, 10% not included in the device group) or mixed contraindications (severe claustrophobia or presence of material magnetic resonance not compatible). Among the 145 survivors, 11 patients received an implantable cardioverter defibrillator after surgery (mostly for persistent low ejection fraction) and were excluded as well, yielding a total of 59 patients (48 men, aged 65 ± 9 years) who repeated a protocol-standardized LGE-cardiac magnetic resonance examination even 6 months postoperatively and therefore represent the study population. Patients were grouped according to the presence of LGE in the antero-basal left ventricular segments (Group A) or the absence of LGE in the same segments (Group B). The postoperative left ventricular end-systolic volume index was considered the primary end-point. After surgery, left ventricular end-systolic volume index and end-diastolic volume index significantly decreased (P < 0.001, for both), while diastolic sphericity index and ejection fraction significantly increased (P = 0.015 and P < 0.001, respectively). The presence of LGE in the antero-basal left ventricular segments (10 patients, Group A) was the only independent predictor of outcome (P = 0.02) at multivariate analysis, being the postoperative left ventricular end-systolic volume index significantly higher compared to that of patients of Group B (49 patients) (78 ± 26 ml/m2 vs 55 ± 20 ml/m2, P = 0.003). Furthermore, patients with a postoperative left ventricular end-systolic volume index >60 ml/m2 showed a higher risk of cardiac events (hazard ratio = 3.67, P = 0.02). In patients undergoing surgical ventricular reconstruction, LGE scar location affects the left ventricular reverse remodelling, which in turn might limit the survival benefit. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Muraru, Denisa; Onciul, Sebastian; Peluso, Diletta; Soriani, Nicola; Cucchini, Umberto; Aruta, Patrizia; Romeo, Gabriella; Cavalli, Giacomo; Iliceto, Sabino; Badano, Luigi P
2016-02-01
Despite the fact that assessment of right ventricular longitudinal strain (RVLS) carries important implications for patient diagnosis, prognosis, and treatment, its implementation in clinical settings has been hampered by the limited reference values and the lack of uniformity in software, method, and definition used for measuring RVLS. Accordingly, this study was designed to establish (1) the reference values for RVLS by 2-dimensional speckle-tracking echocardiography; and (2) their relationship with demographic, hemodynamic, and cardiac factors. In 276 healthy volunteers (55% women; age, 18-76 years), free wall and septum RVLS (6 segments) and free wall RVLS (3 segments) using both 6- and 3-segment regions of interest were obtained. Feasibility of 6-segment RVLS was 92%. Free wall RVLS from 3- versus 6-segment regions of interest had similar values, yet 6-segment region of interest was more feasible (86% versus 73%; P<0.001) and reproducible. Reference values (lower limits of normality) were as follows: 6-segment RVLS, -24.7±2.6% (-20.0%) for men and -26.7±3.1% (-20.3%) for women; 3-segment RVLS, -29.3±3.4% (-22.5%) for men and -31.6±4.0% (-23.3%) for women (P<0.001). Free wall RVLS was 5±2 strain units (%) larger in magnitude than 6-segment RVLS, 10±4% larger than septal RVLS, and 2±4% larger in women than in men (P<0.001). At multivariable analysis, age, sex, pulmonary systolic pressure, right atrial minimal volume, as well as right atrial and left ventricular longitudinal strain resulted as correlates of RVLS values. This is the largest study providing sex- and method-specific reference values for RVLS. Our data may foster the implementation of 2-dimensional speckle-tracking echocardiography-derived RV analysis in clinical practice. © 2016 American Heart Association, Inc.
Furushima, Hiroshi; Chinushi, Masaomi; Iijima, Kenichi; Hasegawa, Kanae; Sato, Akinori; Izumi, Daisuke; Watanabe, Hiroshi; Aizawa, Yoshifusa
2012-05-01
The aim of this study was to determine whether or not the coexistence of sustained ST-segment elevation and abnormal Q waves (STe-Q) could be a risk factor for electrical storm (ES) in implanted cardioverter defibrillator (ICD) patients with structural heart diseases. In all, 156 consecutive patients received ICD therapy for secondary prevention of sudden cardiac death and/or sustained ventricular tachyarrhythmias were included. Electrical storm was defined as ≥3 separate episodes of ventricular tachycardia (VT) and/or ventricular fibrillation (VF) terminated by ICD therapies within 24 h. During a mean follow-up of 1825 ± 1188 days, 42 (26.9%) patients experienced ES, of whom 12 had coronary artery disease, 15 had idiopathic dilated cardiomyopathy, 6 had hypertrophic cardiomyopathy, 4 had arrhythmogenic right ventricular cardiomyopathy, 4 had cardiac sarcoidosis, and 1 had valvular heart disease. Sustained ST-segment elevation and abnormal Q waves in ≥2 leads on the 12-lead electrocardiography was observed in 33 (21%) patients. On the Kaplan-Meier analysis, patients with STe-Q had a markedly higher risk of ES than those without STe-Q (P< 0.0001). The multivariate Cox proportional hazards regression model indicated that STe-Q and left ventricular ejection fraction (LVEF) (<30%) were independent risk factors associated with the recurrence of VT/VF (STe-Q: HR 1.962, 95% CI 1.24-3.12, P= 0.004; LVEF: HR 1.860, 95% CI 1.20-2.89, P= 0.006), and STe-Q was an independent risk factor associated with ES (HR 4.955, 95% CI 2.69-9.13, P< 0.0001). Sustained ST-segment elevation and abnormal Q waves could be a risk factor of not only recurrent VT/VF but also ES in patients with structural heart diseases.
Ali, Anjum A; Dale, Anders M; Badea, Alexandra; Johnson, G Allan
2005-08-15
We present the automated segmentation of magnetic resonance microscopy (MRM) images of the C57BL/6J mouse brain into 21 neuroanatomical structures, including the ventricular system, corpus callosum, hippocampus, caudate putamen, inferior colliculus, internal capsule, globus pallidus, and substantia nigra. The segmentation algorithm operates on multispectral, three-dimensional (3D) MR data acquired at 90-microm isotropic resolution. Probabilistic information used in the segmentation is extracted from training datasets of T2-weighted, proton density-weighted, and diffusion-weighted acquisitions. Spatial information is employed in the form of prior probabilities of occurrence of a structure at a location (location priors) and the pairwise probabilities between structures (contextual priors). Validation using standard morphometry indices shows good consistency between automatically segmented and manually traced data. Results achieved in the mouse brain are comparable with those achieved in human brain studies using similar techniques. The segmentation algorithm shows excellent potential for routine morphological phenotyping of mouse models.
Husser, Oliver; Monmeneu, Jose V; Bonanad, Clara; Lopez-Lereu, Maria P; Nuñez, Julio; Bosch, Maria J; Garcia, Carlos; Sanchis, Juan; Chorro, Francisco J; Bodi, Vicente
2014-09-01
The incremental prognostic value of inducible myocardial ischemia over necrosis derived by stress cardiac magnetic resonance in depressed left ventricular function is unknown. We determined the prognostic value of necrosis and ischemia in patients with depressed left ventricular function referred for dipyridamole stress perfusion magnetic resonance. In a multicenter registry using stress magnetic resonance, the presence (≥ 2 segments) of late enhancement and perfusion defects and their association with major events (cardiac death and nonfatal infarction) was determined. In 391 patients, perfusion defect or late enhancement were present in 224 (57%) and 237 (61%). During follow-up (median, 96 weeks), 47 major events (12%) occurred: 25 cardiac deaths and 22 myocardial infarctions. Patients with major events displayed a larger extent of perfusion defects (6 segments vs 3 segments; P <.001) but not late enhancement (5 segments vs 3 segments; P =.1). Major event rate was significantly higher in the presence of perfusion defects (17% vs 5%; P =.0005) but not of late enhancement (14% vs 9%; P =.1). Patients were categorized into 4 groups: absence of perfusion defect and absence of late enhancement (n = 124), presence of late enhancement and absence of perfusion defect (n = 43), presence of perfusion defect and presence of late enhancement (n = 195), absence of late enhancement and presence of perfusion defect (n = 29). Event rate was 5%, 7%, 16%, and 24%, respectively (P for trend = .003). In a multivariate regression model, only perfusion defect (hazard ratio = 2.86; 95% confidence interval, 1.37-5.95]; P = .002) but not late enhancement (hazard ratio = 1.70; 95% confidence interval, 0.90-3.22; P =.105) predicted events. In depressed left ventricular function, the presence of inducible ischemia is the strongest predictor of major events. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Juliani, Paulo Sérgio; da Costa, Éder França; Correia, Aristides Tadeu; Monteiro, Rosangela; Jatene, Fabio Biscegli
2014-01-01
Introduction A feature of dilated cardiomyopathy is the deformation of ventricular cavity, which contributes to systolic dysfunction. Few studies have evaluated this deformation bearing in mind ventricular regions and segments of the ventricle, which could reveal important details of the remodeling process, supporting a better understanding of its role in functional impairment and the development of new therapeutic strategies. Objective To evaluate if, in basal, equatorial and apical regions, increased internal transverse perimeter of left ventricle in idiopathic dilated cardiomyopathy occurs proportionally between the septal and non-septal segment. Methods We performed an anatomical study with 28 adult hearts from human cadavers. One group consisted of 18 hearts with idiopathic dilated cardiomyopathy and another group with 10 normal hearts. After lamination and left ventricle digital image capture, in three different regions (base, equator and apex), the transversal internal perimeter of left ventricle was divided into two segments: septal and not septal. These segments were measured by proper software. It was established an index of proportionality between these segments, called septal and non-septal segment index. Then we determined whether this index was the same in both groups. Results Among patients with normal hearts and idiopathic dilated cardiomyopathy, the index of proportionality between the two segments (septal and non-septal) showed no significant difference in the three regions analyzed. The comparison results of the indices NSS/SS among normal and enlarged hearts were respectively: in base 1.99 versus 1.86 (P=0.46), in equator 2.22 versus 2.18 (P=0.79) and in apex 2.96 versus 3.56 (P=0.11). Conclusion In the idiopathic dilated cardiomyopathy, the transversal dilatation of left ventricular internal perimeter occurs proportionally between the segments corresponding to the septum and free wall at the basal, equatorial and apical regions of this chamber. PMID:25372906
Flying saucer located at the basal septum.
Akcay, Murat; Senkaya, Emine Bilen; Bilge, Mehmet; Bozkurt, Mehmet; Arslantas, Ugur; Karakas, Fatih
2008-08-01
Left ventricular thrombus formation is a frequent complication in patients with ischemic heart disease and is associated with a high risk of systemic embolization. Generally, thrombi localize at the apical segment. However, thrombus localized at the basal septum has not been reported yet. In this case, we discuss a flying saucer shaped mass located at the basal septum, which was later diagnosed as thrombus after anticoagulant therapy.
Ukwatta, Eranga; Arevalo, Hermenegild; Li, Kristina; Yuan, Jing; Qiu, Wu; Malamas, Peter; Wu, Katherine C.
2016-01-01
Accurate representation of myocardial infarct geometry is crucial to patient-specific computational modeling of the heart in ischemic cardiomyopathy. We have developed a methodology for segmentation of left ventricular (LV) infarct from clinically acquired, two-dimensional (2D), late-gadolinium enhanced cardiac magnetic resonance (LGE-CMR) images, for personalized modeling of ventricular electrophysiology. The infarct segmentation was expressed as a continuous min-cut optimization problem, which was solved using its dual formulation, the continuous max-flow (CMF). The optimization objective comprised of a smoothness term, and a data term that quantified the similarity between image intensity histograms of segmented regions and those of a set of training images. A manual segmentation of the LV myocardium was used to initialize and constrain the developed method. The three-dimensional geometry of infarct was reconstructed from its segmentation using an implicit, shape-based interpolation method. The proposed methodology was extensively evaluated using metrics based on geometry, and outcomes of individualized electrophysiological simulations of cardiac dys(function). Several existing LV infarct segmentation approaches were implemented, and compared with the proposed method. Our results demonstrated that the CMF method was more accurate than the existing approaches in reproducing expert manual LV infarct segmentations, and in electrophysiological simulations. The infarct segmentation method we have developed and comprehensively evaluated in this study constitutes an important step in advancing clinical applications of personalized simulations of cardiac electrophysiology. PMID:26731693
Žižek, David; Cvijić, Marta; Ležaić, Luka; Salobir, Barbara Gužič; Zupan, Igor
2013-12-01
The presence of myocardial fibrosis is associated with ventricular tachyarrhythmia (VT) occurrence irrespective of cardiomyopathy etiology. The aim of our study was to evaluate the impact of global and regional viability on VTs in patients undergoing cardiac resynchronization therapy (CRT). Fifty-seven patients with advanced heart failure (age 62.3 ± 10.2; 38 men; 24 ischemic etiology) were evaluated using single-photon emission computed tomography myocardial perfusion imaging before CRT defibrillator device implantation. Global myocardial viability was determined by the number of viable segments in a 20-segment model. Regional viability was calculated as the mean tracer activity in the corresponding segments at left ventricular (LV) lead position. LV lead segments were determined at implant venography using 2 projections (left anterior oblique 30 and right anterior oblique 30) of coronary sinus tributaries. Patients were followed 30 (24-34) months for the occurrence of VTs. VTs were registered in 18 patients (31.6%). Patients without VTs had significantly more viable segments (17.6 ± 2.35 vs 14.2 ± 4.0; P = .002) and higher regional myocardial viability at LV lead position (66.1% ± 10.3% vs 54.8% ± 11.4% of tracer activity; P = .001) than those with VTs. In multivariate logistic regression models, the number of viable segments (OR = 0.66; 95% confidence interval (CI) 0.53-0.85; P = .001) and regional viability (OR = 0.90; 95% CI 0.85-0.97; P = .003) were the only independent predictors of VT occurrence. Global and regional myocardial viability are independently related to the occurrence of VTs in patients after CRT.
Tabereaux, Paul B; Walcott, Greg P; Rogers, Jack M; Kim, Jong; Dosdall, Derek J; Robertson, Peter G; Killingsworth, Cheryl R; Smith, William M; Ideker, Raymond E
2007-09-04
The roles of Purkinje fibers (PFs) and focal wave fronts, if any, in the maintenance of ventricular fibrillation (VF) are unknown. If PFs are involved in VF maintenance, it should be possible to map wave fronts propagating from PFs into the working ventricular myocardium during VF. If wave fronts ever arise focally during VF, it should be possible to map them appearing de novo. Six canine hearts were isolated, and the left main coronary artery was cannulated and perfused. The left ventricular cavity was exposed, which allowed direct endocardial mapping of the anterior papillary muscle insertion. Nonperfused VF was induced, and 6 segments of data, each 5 seconds long, were analyzed during 10 minutes of VF. During 36 segments of data that were analyzed, 1018 PF or focal wave fronts of activation were identified. In 534 wave fronts, activation was mapped propagating from working ventricular myocardium to PF. In 142 wave fronts, activation was mapped propagating from PF to working ventricular myocardium. In 342 wave fronts, activation was mapped arising focally. More than 1 of these 3 patterns could occur in the same wave front. PFs are highly active throughout the first 10 minutes of VF. In addition to retrograde propagation from the working ventricular myocardium to PFs, antegrade propagation occurs from PFs to working ventricular myocardium, which suggests PFs are important in VF maintenance. Prior plunge needle recordings in dogs indicate activation propagates from the endocardium toward the epicardium after 1 minute of VF, which suggests that focal sites on the endocardium may represent foci and not breakthrough. If so, in addition to reentry, abnormal automaticity or triggered activity may also occur during VF.
Schroeder, Carsten; Chung, Jane M; Mackall, Judith A; Cakulev, Ivan T; Patel, Aaron; Patel, Sunny J; Hoit, Brian D; Sahadevan, Jayakumar
2018-06-14
The aim of the study was to study the feasibility, safety, and efficacy of transesophageal echocardiography-guided intraoperative left ventricular lead placement via a video-assisted thoracoscopic surgery approach in patients with failed conventional biventricular pacing. Twelve patients who could not have the left ventricular lead placed conventionally underwent epicardial left ventricular lead placement by video-assisted thoracoscopic surgery. Eight patients had previous chest surgery (66%). Operative positioning was a modified far lateral supine exposure with 30-degree bed tilt, allowing for groin and sternal access. To determine the optimal left ventricular location for lead placement, the left ventricular surface was divided arbitrarily into nine segments. These segments were transpericardially paced using a hand-held malleable pacing probe identifying the optimal site verified by transesophageal echocardiography. The pacing leads were screwed into position via a limited pericardiotomy. The video-assisted thoracoscopic surgery approach was successful in all patients. Biventricular pacing was achieved in all patients and all reported symptomatic benefit with reduction in New York Heart Association class from III to I-II (P = 0.016). Baseline ejection fraction was 23 ± 3%; within 1-year follow-up, the ejection fraction increased to 32 ± 10% (P = 0.05). The mean follow-up was 566 days. The median length of hospital stay was 7 days with chest tube removal between postoperative days 2 and 5. In patients who are nonresponders to conventional biventricular pacing, intraoperative left ventricular lead placement using anatomical and functional characteristics via a video-assisted thoracoscopic surgery approach is effective in improving heart failure symptoms. This optimized left ventricular lead placement is feasible and safe. Previous chest surgery is no longer an exclusion criterion for a video-assisted thoracoscopic surgery approach.
Chen, Wei-Ren; Shen, Xue-Qin; Zhang, Ying; Chen, Yun-Dai; Hu, Shun-Ying; Qian, Geng; Wang, Jing; Yang, Jun-Jie; Wang, Zhi-Feng; Tian, Feng
2016-06-01
The influence of glucagon-like peptide-1 has been studied in several studies in patients with acute myocardial infarction, but not in patients with non-ST-segment elevation myocardial infarction (NSTEMI). We planned to evaluate the effects of liraglutide on left ventricular function in patients with NSTEMI. A total of 90 patients were randomized 1:1 to receive either liraglutide (0.6 mg for 2 days, 1.2 mg for 2 days, followed by 1.8 mg for 3 days) or placebo for 7 days. Eighty-three patients completed the trial. Transthoracic echocardiography was used to assess left ventricular function. At 3 months, the primary endpoint, the difference in the change in left ventricular ejection fraction between the two groups was +4.7 % (liraglutide vs. placebo 95 % CI +0.7 to +9.2 % P = 0.009) under intention-to-treat analysis. The difference in decrease in serum glycosylated hemoglobin levels was -0.2 % (liraglutide vs. placebo 95 % CI -0.1 to -0.3 %; P < 0.001). Inflammation and oxidative stress improved significantly in the liraglutide group compared to the placebo group. Liraglutide could improve left ventricular function in patients with NSTEMI, making it a potential adjuvant therapy for NSTEMI.
van Dam, Peter M; Gordon, Jeffrey P; Laks, Michael M; Boyle, Noel G
2015-01-01
Non-invasive electrocardiographic imaging (ECGI) of the cardiac muscle can help the pre-procedure planning of the ablation of ventricular arrhythmias by reducing the time to localize the origin. Our non-invasive ECGI system, the cardiac isochrone positioning system (CIPS), requires non-intersecting meshes of the heart, lungs and torso. However, software to reconstruct the meshes of the heart, lungs and torso with the capability to check and prevent these intersections is currently lacking. Consequently the reconstruction of a patient specific model with realistic atrial and ventricular wall thickness and incorporating blood cavities, lungs and torso usually requires additional several days of manual work. Therefore new software was developed that checks and prevents any intersections, and thus enables the use of accurate reconstructed anatomical models within CIPS. In this preliminary study we investigated the accuracy of the created patient specific anatomical models from MRI or CT. During the manual segmentation of the MRI data the boundaries of the relevant tissues are determined. The resulting contour lines are used to automatically morph reference meshes of the heart, lungs or torso to match the boundaries of the morphed tissue. Five patients were included in the study; models of the heart, lungs and torso were reconstructed from standard cardiac MRI images. The accuracy was determined by computing the distance between the segmentation contours and the morphed meshes. The average accuracy of the reconstructed cardiac geometry was within 2mm with respect to the manual segmentation contours on the MRI images. Derived wall volumes and left ventricular wall thickness were within the range reported in literature. For each reconstructed heart model the anatomical heart axis was computed using the automatically determined anatomical landmarks of the left apex and the mitral valve. The accuracy of the reconstructed heart models was well within the accuracy of the used medical image data (pixel size <1.5mm). For the lungs and torso the number of triangles in the mesh was reduced, thus decreasing the accuracy of the reconstructed mesh. A novel software tool has been introduced, which is able to reconstruct accurate cardiac anatomical models from MRI or CT within only a few hours. This new anatomical reconstruction tool might reduce the modeling errors within the cardiac isochrone positioning system and thus enable the clinical application of CIPS to localize the PVC/VT focus to the ventricular myocardium from only the standard 12 lead ECG. Copyright © 2015 Elsevier Inc. All rights reserved.
New micro waveforms firstly recorded on electrocardiogram in human.
Liu, Renguang; Chang, Qinghua; Chen, Juan
2015-10-01
In our study, not only the P-QRS-T waves but also the micro-wavelets before QRS complex (in P wave and PR segment) and after QRS complex (ST segment and upstroke of T wave) were first to be identified on surface electrocardiogram in human by the "new electrocardiogram" machine (model PHS-A10) according to conventional 12-lead electrocardiogram connection methods. By comparison to the conventional electrocardiogram in 100 cases of healthy individuals and several patients with arrhythmias, we have found that the wavelets before P wave theoretically reflected electrical activity of sinus node and the micro-wavelets before QRS complex may be related to atrioventricular conduction system (atrioventricular node, His bundle and bundle branch) potentials. Noninvasive atrioventricular node and His bundle potential tracing will contribute to differentiation of the origin of wide QRS and the location of the atrioventricular block. We also have found that the wavelets after QRS complex may be associated with phase 2 and 3 repolarization of ventricular action potential, which will further reveal ventricular repolarization changes. Copyright © 2015 Elsevier Ltd. All rights reserved.
Tan, Li Kuo; Liew, Yih Miin; Lim, Einly; Abdul Aziz, Yang Faridah; Chee, Kok Han; McLaughlin, Robert A
2018-06-01
In this paper, we develop and validate an open source, fully automatic algorithm to localize the left ventricular (LV) blood pool centroid in short axis cardiac cine MR images, enabling follow-on automated LV segmentation algorithms. The algorithm comprises four steps: (i) quantify motion to determine an initial region of interest surrounding the heart, (ii) identify potential 2D objects of interest using an intensity-based segmentation, (iii) assess contraction/expansion, circularity, and proximity to lung tissue to score all objects of interest in terms of their likelihood of constituting part of the LV, and (iv) aggregate the objects into connected groups and construct the final LV blood pool volume and centroid. This algorithm was tested against 1140 datasets from the Kaggle Second Annual Data Science Bowl, as well as 45 datasets from the STACOM 2009 Cardiac MR Left Ventricle Segmentation Challenge. Correct LV localization was confirmed in 97.3% of the datasets. The mean absolute error between the gold standard and localization centroids was 2.8 to 4.7 mm, or 12 to 22% of the average endocardial radius. Graphical abstract Fully automated localization of the left ventricular blood pool in short axis cardiac cine MR images.
3D MR ventricle segmentation in pre-term infants with post-hemorrhagic ventricle dilation
NASA Astrophysics Data System (ADS)
Qiu, Wu; Yuan, Jing; Kishimoto, Jessica; Chen, Yimin; de Ribaupierre, Sandrine; Chiu, Bernard; Fenster, Aaron
2015-03-01
Intraventricular hemorrhage (IVH) or bleed within the brain is a common condition among pre-term infants that occurs in very low birth weight preterm neonates. The prognosis is further worsened by the development of progressive ventricular dilatation, i.e., post-hemorrhagic ventricle dilation (PHVD), which occurs in 10-30% of IVH patients. In practice, predicting PHVD accurately and determining if that specific patient with ventricular dilatation requires the ability to measure accurately ventricular volume. While monitoring of PHVD in infants is typically done by repeated US and not MRI, once the patient has been treated, the follow-up over the lifetime of the patient is done by MRI. While manual segmentation is still seen as a gold standard, it is extremely time consuming, and therefore not feasible in a clinical context, and it also has a large inter- and intra-observer variability. This paper proposes a segmentation algorithm to extract the cerebral ventricles from 3D T1- weighted MR images of pre-term infants with PHVD. The proposed segmentation algorithm makes use of the convex optimization technique combined with the learned priors of image intensities and label probabilistic map, which is built from a multi-atlas registration scheme. The leave-one-out cross validation using 7 PHVD patient T1 weighted MR images showed that the proposed method yielded a mean DSC of 89.7% +/- 4.2%, a MAD of 2.6 +/- 1.1 mm, a MAXD of 17.8 +/- 6.2 mm, and a VD of 11.6% +/- 5.9%, suggesting a good agreement with manual segmentations.
Evolving J waves prior to ventricular fibrillation postoperative coronary bypass.
Kitazawa, Hitoshi; Wakasugi, Takayuki; Sugimoto, Tsutomu; Yamamoto, Kazuo; Yoshii, Shinpei; Aizawa, Yoshifusa
2011-01-01
A 74-year-old man without history of ventricular arrhythmias underwent coronary bypass surgery for 3-vessel disease. On the 4th postoperative day, he developed ventricular fibrillation (VF). His monitored ECG showed no elevation of the ST-segment and no prolongation of QT interval, but evolving J waves prior to VF were shown. These J waves gradually decreased after defibrillation. The subsequent angiography revealed patent grafts and normal left ventricular function. J waves reappeared in inferior leads when contrast medium was injected into the coronary artery. Therefore, evolving J wave can be a marker of latent ischemia and a predictor of VF.
Fu, Yili; Gao, Wenpeng; Chen, Xiaoguang; Zhu, Minwei; Shen, Weigao; Wang, Shuguo
2010-01-01
The reference system based on the fourth ventricular landmarks (including the fastigial point and ventricular floor plane) is used in medical image analysis of the brain stem. The objective of this study was to develop a rapid, robust, and accurate method for the automatic identification of this reference system on T1-weighted magnetic resonance images. The fully automated method developed in this study consisted of four stages: preprocessing of the data set, expectation-maximization algorithm-based extraction of the fourth ventricle in the region of interest, a coarse-to-fine strategy for identifying the fastigial point, and localization of the base point. The method was evaluated on 27 Brain Web data sets qualitatively and 18 Internet Brain Segmentation Repository data sets and 30 clinical scans quantitatively. The results of qualitative evaluation indicated that the method was robust to rotation, landmark variation, noise, and inhomogeneity. The results of quantitative evaluation indicated that the method was able to identify the reference system with an accuracy of 0.7 +/- 0.2 mm for the fastigial point and 1.1 +/- 0.3 mm for the base point. It took <6 seconds for the method to identify the related landmarks on a personal computer with an Intel Core 2 6300 processor and 2 GB of random-access memory. The proposed method for the automatic identification of the reference system based on the fourth ventricular landmarks was shown to be rapid, robust, and accurate. The method has potentially utility in image registration and computer-aided surgery.
Wang, Rui; Meinel, Felix G; Schoepf, U Joseph; Canstein, Christian; Spearman, James V; De Cecco, Carlo N
2015-12-01
To evaluate the accuracy, reliability and time saving potential of a novel cardiac CT (CCT)-based, automated software for the assessment of segmental left ventricular function compared to visual and manual quantitative assessment of CCT and cardiac magnetic resonance (CMR). Forty-seven patients with suspected or known coronary artery disease (CAD) were enrolled in the study. Wall thickening was calculated. Segmental LV wall motion was automatically calculated and shown as a colour-coded polar map. Processing time for each method was recorded. Mean wall thickness in both systolic and diastolic phases on polar map, CCT, and CMR was 9.2 ± 0.1 mm and 14.9 ± 0.2 mm, 8.9 ± 0.1 mm and 14.5 ± 0.1 mm, 8.3 ± 0.1 mm and 13.6 ± 0.1 mm, respectively. Mean wall thickening was 68.4 ± 1.5 %, 64.8 ± 1.4 % and 67.1 ± 1.4 %, respectively. Agreement for the assessment of LV wall motion between CCT, CMR and polar maps was good. Bland-Altman plots and ICC indicated good agreement between CCT, CMR and automated polar maps of the diastolic and systolic segmental wall thickness and thickening. The processing time using polar map was significantly decreased compared with CCT and CMR. Automated evaluation of segmental LV function with polar maps provides similar measurements to manual CCT and CMR evaluation, albeit with substantially reduced analysis time. • Cardiac computed tomography (CCT) can accurately assess segmental left ventricular wall function. • A novel automated software permits accurate and fast evaluation of wall function. • The software may improve the clinical implementation of segmental functional analysis.
Huang, Hsiao-Hui; Huang, Chun-Yu; Chen, Chiao-Ning; Wang, Yun-Wen; Huang, Teng-Yi
2018-01-01
Native T1 value is emerging as a reliable indicator of abnormal heart conditions related to myocardial fibrosis. Investigators have extensively used the standardized myocardial segmentation of the American Heart Association (AHA) to measure regional T1 values of the left ventricular (LV) walls. In this paper, we present a fully automatic system to analyze modified Look-Locker inversion recovery images and to report regional T1 values of AHA segments. Ten healthy individuals participated in the T1 mapping study with a 3.0 T scanner after providing informed consent. First, we obtained masks of an LV blood-pool region and LV walls by using an image synthesis method and a layer-growing method. Subsequently, the LV walls were divided into AHA segments by identifying the boundaries of the septal regions and by using a radial projection method. The layer-growing method significantly enhanced the accuracy of the derived myocardium mask. We compared the T1 values that were obtained using manual region of interest selections and those obtained using the automatic system. The average T1 difference of the calculated segments was 4.6 ± 1.5%. This study demonstrated a practical and robust method of obtaining native T1 values of AHA segments in LV walls.
Guo, Li-Li; Wang, Jie; Lin, Fei; He, Yong-Xia
2014-09-01
To explore the effect of Danlou Tablet (DT) on arrhythmia model rats induced by transient myocardial ischemia/reperfusion (I/R). Totally 45 healthy Wistar rats were randomly divided into 3 groups, the sham-operation group, the model group, and the DT group, 15 in each group. Rats in the sham-operation group and the model group were administered with distilled water by gastrogavage at the daily dose of 0.1 mL/kg. Rats in the DT group was administered with 0.53 g/mL DT suspension by gastrogavage at the daily dose of 0.1 mL/kg. All medication was lasted for 10 successive days. The myocardial I/R experiment was performed at 1 h after the last gastrogavage. ECG was performed before ligation and at I/R. The jugular arterial blood pressure of all rats was measured during the whole course. ST segment changes were observed at each time point of I/R. The ventricular fibrillation, the premature ventricular, the number and the duration of ventricular tachycardia within 30 min reperfusion were also observed. Activities of Na(+)-K+ ATPase and Ca2+ ATPase in the myocardium homogenate were detected as well. The jugular arterial blood pressure and the heart rate were slightly lower in the DT group than in the model group, but with no statistical difference (P > 0.05). Compared with the sham-operation group, the degree of ST segment was obviously elevated in the model group at 0, 5, and 7 min (P < 0.05). It was significantly lower in the DT group than in the model group (P < 0.01). ST seg ment was more elevated at 5 min than at 0 min in the model group, but the degree of ST segment elevation was still obviously lower in the DT group than in the model group (P < 0.05). There was no statistical difference in the degree of ST segment elevation at 7 min between the two groups (P > 0.05). At 0 min when the decrement of ST segment exceeded one half the ischemia, there was no statistical difference in the degree of myocardial ischemia between the model group and the DT group (P > 0.05). Compared with the model group, the incidence of fatal and nonfatal ventricular fibrillation, the frequency and duration of ventricular tachycardia and premature ventricular beats were obviously lessened, and activities of Na(+)-K+ ATPase and Ca(2+)-ATPase increased (all P < 0.05). DT could significantly protect arrhythmias induced by transient I/R. Its effect might be related to lowering the degree of myocardial ischemia, and increasing ion transport channel related enzyme activities.
Park, Hyukjin; Kim, Hyun Kuk; Jeong, Myung Ho; Cho, Jae Yeong; Lee, Ki Hong; Sim, Doo Sun; Yoon, Nam Sik; Yoon, Hyun Ju; Hong, Young Joon; Kim, Kye Hun; Park, Hyung Wook; Kim, Ju Han; Ahn, Youngkeun; Cho, Jeong Gwan; Park, Jong Chun; Kim, Young Jo; Cho, Myeong Chan; Kim, Chong Jim
2017-01-01
Successful percutaneous coronary intervention (PCI) of the occluded infarct-related artery (IRA) in latecomers may improve long-term survival mainly by reducing left ventricular remodeling. It is not clear whether inhibition of renin-angiotensin system (RAS) brings additional better clinical outcomes in this specific population subset. Between January 2008 and June 2013, 669 latecomer patients with acute ST-segment elevation myocardial infarction (STEMI) (66.2±12.1 years, 71.0% males) in Korea Acute Myocardial Infarction Registry (KAMIR) who underwent a successful PCI were enrolled. The study population underwent a successful PCI for a totally occluded IRA. They were divided into two groups according to whether they were prescribed RAS inhibitors at the time of discharge: group I (RAS inhibition, n=556), and group II (no RAS inhibition, n=113). During the one-year follow-up, major adverse cardiac events (MACE), which consist of cardiac death and myocardial infarction, occurred in 71 patients (10.6%). There were significantly reduced incidences of MACE in the group I (hazard ratio=0.34, 95% confidence interval 0.199-0.588, p=0.001). In subgroup analyses, RAS inhibition was beneficial in patients with male gender, history of hypertension or diabetes mellitus, and even in patients with left ventricular ejection fraction (LVEF) ≥40%. In the baseline and follow-up echocardiographic data, benefit in changes of LVEF and left ventricular end-systolic volume was noted in group I. In latecomers with STEMI, RAS inhibition improved long-term clinical outcomes after a successful PCI, even in patients with low risk who had relatively preserved LVEF. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Honghai; Abiose, Ademola K.; Campbell, Dwayne N.; Sonka, Milan; Martins, James B.; Wahle, Andreas
2010-03-01
Quantitative analysis of the left ventricular shape and motion patterns associated with left ventricular mechanical dyssynchrony (LVMD) is essential for diagnosis and treatment planning in congestive heart failure. Real-time 3D echocardiography (RT3DE) used for LVMD analysis is frequently limited by heavy speckle noise or partially incomplete data, thus a segmentation method utilizing learned global shape knowledge is beneficial. In this study, the endocardial surface of the left ventricle (LV) is segmented using a hybrid approach combining active shape model (ASM) with optimal graph search. The latter is used to achieve landmark refinement in the ASM framework. Optimal graph search translates the 3D segmentation into the detection of a minimum-cost closed set in a graph and can produce a globally optimal result. Various information-gradient, intensity distributions, and regional-property terms-are used to define the costs for the graph search. The developed method was tested on 44 RT3DE datasets acquired from 26 LVMD patients. The segmentation accuracy was assessed by surface positioning error and volume overlap measured for the whole LV as well as 16 standard LV regions. The segmentation produced very good results that were not achievable using ASM or graph search alone.
Automatic segmentation of brain MRIs and mapping neuroanatomy across the human lifespan
NASA Astrophysics Data System (ADS)
Keihaninejad, Shiva; Heckemann, Rolf A.; Gousias, Ioannis S.; Rueckert, Daniel; Aljabar, Paul; Hajnal, Joseph V.; Hammers, Alexander
2009-02-01
A robust model for the automatic segmentation of human brain images into anatomically defined regions across the human lifespan would be highly desirable, but such structural segmentations of brain MRI are challenging due to age-related changes. We have developed a new method, based on established algorithms for automatic segmentation of young adults' brains. We used prior information from 30 anatomical atlases, which had been manually segmented into 83 anatomical structures. Target MRIs came from 80 subjects (~12 individuals/decade) from 20 to 90 years, with equal numbers of men, women; data from two different scanners (1.5T, 3T), using the IXI database. Each of the adult atlases was registered to each target MR image. By using additional information from segmentation into tissue classes (GM, WM and CSF) to initialise the warping based on label consistency similarity before feeding this into the previous normalised mutual information non-rigid registration, the registration became robust enough to accommodate atrophy and ventricular enlargement with age. The final segmentation was obtained by combination of the 30 propagated atlases using decision fusion. Kernel smoothing was used for modelling the structural volume changes with aging. Example linear correlation coefficients with age were, for lateral ventricular volume, rmale=0.76, rfemale=0.58 and, for hippocampal volume, rmale=-0.6, rfemale=-0.4 (allρ<0.01).
Antunes, Sofia; Esposito, Antonio; Palmisano, Anna; Colantoni, Caterina; Cerutti, Sergio; Rizzo, Giovanna
2016-05-01
Extraction of the cardiac surfaces of interest from multi-detector computed tomographic (MDCT) data is a pre-requisite step for cardiac analysis, as well as for image guidance procedures. Most of the existing methods need manual corrections, which is time-consuming. We present a fully automatic segmentation technique for the extraction of the right ventricle, left ventricular endocardium and epicardium from MDCT images. The method consists in a 3D level set surface evolution approach coupled to a new stopping function based on a multiscale directional second derivative Gaussian filter, which is able to stop propagation precisely on the real boundary of the structures of interest. We validated the segmentation method on 18 MDCT volumes from healthy and pathologic subjects using manual segmentation performed by a team of expert radiologists as gold standard. Segmentation errors were assessed for each structure resulting in a surface-to-surface mean error below 0.5 mm and a percentage of surface distance with errors less than 1 mm above 80%. Moreover, in comparison to other segmentation approaches, already proposed in previous work, our method presented an improved accuracy (with surface distance errors less than 1 mm increased of 8-20% for all structures). The obtained results suggest that our approach is accurate and effective for the segmentation of ventricular cavities and myocardium from MDCT images.
Elias, Joëlle; van Dongen, Ivo M; Hoebers, Loes P; Ouweneel, Dagmar M; Claessen, Bimmer E P M; Råmunddal, Truls; Laanmets, Peep; Eriksen, Erlend; van der Schaaf, René J; Ioanes, Dan; Nijveldt, Robin; Tijssen, Jan G; Hirsch, Alexander; Henriques, José P S
2017-07-19
The Evaluating Xience and left ventricular function in PCI on occlusiOns afteR STEMI (EXPLORE) trial did not show a significant benefit of percutaneous coronary intervention (PCI) of the concurrent chronic total occlusion (CTO) in ST-segment elevation myocardial infarction (STEMI) patients on global left ventricular (LV) systolic function. However a possible treatment effect will be most pronounced in the CTO territory. Therefore, we aimed to study the effect of CTO PCI compared to no-CTO PCI on the recovery of regional LV function, particularly in the CTO territory. Using cardiovascular magnetic resonance (CMR) we studied 180 of the 302 EXPLORE patients with serial CMR (baseline and 4 months follow-up). Segmental wall thickening (SWT) was quantified on cine images by an independent core laboratory. Dysfunctional segments were defined as SWT < 45%. Dysfunctional segments were further analyzed by viability (transmural extent of infarction (TEI) ≤50%.). All outcomes were stratified for randomization treatment. In the dysfunctional segments in the CTO territory recovery of SWT was better after CTO PCI compared to no-CTO PCI (ΔSWT 17 ± 27% vs 11 ± 23%, p = 0.03). This recovery was most pronounced in the dysfunctional but viable segments(TEI < 50%) (ΔSWT 17 ± 27% vs 11 ± 22%, p = 0.02). Furthermore in the CTO territory, recovery of SWT was significantly better in the dysfunctional segments in patients with Rentrop grade 2-3 collaterals compared to grade 0-1 collaterals to the CTO (16 ± 26% versus 11 ± 24%, p = 0.04). CTO PCI compared with no-CTO PCI is associated with a greater recovery of regional systolic function in the CTO territory, especially in the dysfunctional but viable segments. Further research is needed to evaluate the use of CMR in selecting post-STEMI patients for CTO PCI and the effect of regional LV function recovery on clinical outcome. Trialregister.nl NTR1108 , Date registered NTR: 30-okt-2007.
Electrocardiographic left ventricular strain pattern: everything old is new again.
Schocken, Douglas D
2014-01-01
Electrocardiographic left ventricular hypertrophy (LVH) has many faces with countless features. Beyond the classic measures of LVH, including QRS voltage and duration, the left ventricular (LV) strain pattern is an element whereby characteristic R-ST depression is followed by a concave ST segment that ends in an asymmetrically inverted T wave. The LV strain pattern generally appears in states of increased systemic blood pressure and must be differentiated from similar but not identical ST-T waves indicating ischemia. The LV strain pattern has been found in population studies to be associated with poor prognosis and increased risk of adverse cardiovascular outcomes. Regression of LV strain pattern parallels decline in systemic BP during clinical trials of anti-hypertensive therapies but does not indicate or serve as a surrogate for decrease in LV mass. Newer techniques in data collection and processing may allow the process of strain to be studied in more detail to determine the ways in which electrical remodeling of the left ventricle as characterized by LVH with 'repolarization abnormalities' indicates how CV risk might be managed by using LV strain pattern as an electrocardiographic biomarker. Copyright © 2014 Elsevier Inc. All rights reserved.
Pneumatic Distension of Ventricular Mural Architecture Validated Histologically.
Burg, M C; Lunkenheimer, P; Niederer, P; Brune, C; Redmann, K; Smerup, M; Spiegel, U; Becker, F; Maintz, D; Heindel, W; Anderson, R H
2016-11-01
Purpose: There are ongoing arguments as to how cardiomyocytes are aggregated together within the ventricular walls. We used pneumatic distension through the coronary arteries to exaggerate the gaps between the aggregated cardiomyocytes, analyzing the pattern revealed using computed tomography, and validating our findings by histology. Methods: We distended 10 porcine hearts, arresting 4 in diastole by infusion of cardioplegic solutions, and 4 in systole by injection of barium chloride. Mural architecture was revealed by computed tomography, measuring also the angulations of the long chains of cardiomyocytes. We prepared the remaining 2 hearts for histology by perfusion with formaldehyde. Results: Increasing pressures of pneumatic distension elongated the ventricular walls, but produced insignificant changes in mural thickness. The distension exaggerated the spaces between the aggregated cardiomyocytes, compartmenting the walls into epicardial, central, and endocardial regions, with a feathered arrangement of transitions between them. Marked variation was noted in the thicknesses of the parts in the different ventricular segments, with no visible anatomical boundaries between them. Measurements of angulations revealed intruding and extruding populations of cardiomyocytes that deviated from a surface-parallel alignment. Scrolling through the stacks of tomographic images revealed marked spiraling of the aggregated cardiomyocytes when traced from base to apex. Conclusion: Our findings call into question the current assumption that cardiomyocytes are uniformly aggregated together in a tangential fashion. There is marked heterogeneity in the architecture of the different ventricular segments, with the aggregated units never extending in a fully transmural fashion. Key Points: • Pneumographic computed tomography reveals an organized structure of the ventricular walls.• Aggregated cardiomyocytes form a structured continuum, with marked regional heterogeneity.• Global ventricular function results from antagonistic forces generated by aggregated cardiomyocytes. Citation Format: • Burg MC, Lunkenheimer P, Niederer P et al. Pneumatic Distension of Ventricular Mural Architecture Validated Histologically. Fortschr Röntgenstr 2016; 188: 1045 - 1053. © Georg Thieme Verlag KG Stuttgart · New York.
Elsokkari, Ihab; Sapp, John L; Doucette, Steve; Parkash, Ratika; Gray, Christopher J; Gardner, Martin J; Macintyre, Ciorsti; AbdelWahab, Amir M
2018-06-26
Contact force-sensing technology has become a widely used addition to catheter ablation procedures. Neither the optimal contact force required to achieve adequate lesion formation in the ventricle, nor the impact of left ventricular access route on contact force has been fully clarified. Consecutive patients (n = 24) with ischemic cardiomyopathy who underwent ablation for scar-related ventricular tachycardia were included in the study. All ablations (n = 25) were performed using irrigated contact force-sensing catheters (Smart Touch, Biosense Webster). Effective lesion formation was defined as electrical unexcitability post ablation at sites which were electrically excitable prior to ablation (unipolar pacing at 10 mA, 2 ms pulse width). We explored the contact force which achieved effective lesion formation and the impact of left ventricular access route (retrograde aortic or transseptal) on the contact force achieved in various segments of the left ventricle. Scar zone was defined as bipolar signal amplitude < 0.5 mV. Among 427 ablation points, effective lesion formation was achieved at 201 points (47.1%). Contact force did not predict effective lesion formation in the overall group. However, within the scar zone, mean contact force ≥ 10 g was significantly associated with effective lesion formation [OR 3.21 (1.43, 7.19) P = 0.005]. In the 12-segment model of the left ventricle, the retrograde approach was associated with higher median contact force in the apical anterior segment (31 vs 19 g; P = 0.045) while transseptal approach had higher median force in the basal inferior segment (25 vs 15 g; P = 0.021). In the 4-segment model, the retrograde approach had higher force in the anterior wall (28 vs 16 g; P = 0.004) while the transseptal approach had higher force in the lateral wall (21 vs 18 g; P = 0.032). There was a trend towards higher force in the inferior wall with the transseptal approach, but this was not statistically significant (20 vs 15 g; P = 0.063). In patients with ischemic cardiomyopathy, a mean contact force of 10 g or more within the scar zone had the best correlation with electrical unexcitability post ablation in our study. The retrograde aortic approach was associated with better contact force over the anterior wall while use of a transseptal approach had better contact force over the lateral wall.
Li, Zhaohuan; Tang, Hong; Feng, Yuan
2008-11-01
To analyze longitudinal motion of infarcted myocardium and ischemic myocardium with a new echocardiographic technology of velocity vector imaging (VVI), and to assess its accuracy. From December 2007 to January 2008, 6 patients suffered acute anterior myocardial infarction (MI group), 9 patients had myocardial ischemia (over 70% stenosis of anterior descending branch, MS group) and 16 healthy subjects (control group) were included. The long axis view and 2-chambers view of left ventricle at the apex of heart were acquired with Siemens Sequoia 512 ultrasound system. The longitudinal velocity, displacement, strain and strain rate were analyzed with off-line Syngo US workplace software. In normal myocardial group, longitudinal peak systolic velocity (Vs) and peak displacement (D) decreased progressively from base level to apex level in anterior wall and anterior septum (P < 0.05), while peak strain (S) and peak systolic strain rate (SRs) kept the same in three levels (P > 0.05). S and SRs significantly decreased in all segments of infarcted myocardium (P < 0.05), compared with normal and ischemic myocardium. In ischemic myocardium, only base and middle segmental S of anterior wall decreased (P < 0.05). A myocardial S lower than -6.94% in at least one ventricular segment showed best sensitivity (100%) and specificity (100%) for detecting an infarcted left ventricle. A myocardial SRs lower than -0.81% at least in one ventricular segment showed 100% sensitivity and 80% specificity, and lower than -0.46% showed 83% sensitivity and 100% specificity. VVI is a useful tool for assessing myocardial regional function. Especially, S and SRs are useful predictors of the presence of regional dysfunction in infarcted myocardium.
[Cardiac Synchronization Function Estimation Based on ASM Level Set Segmentation Method].
Zhang, Yaonan; Gao, Yuan; Tang, Liang; He, Ying; Zhang, Huie
At present, there is no accurate and quantitative methods for the determination of cardiac mechanical synchronism, and quantitative determination of the synchronization function of the four cardiac cavities with medical images has a great clinical value. This paper uses the whole heart ultrasound image sequence, and segments the left & right atriums and left & right ventricles of each frame. After the segmentation, the number of pixels in each cavity and in each frame is recorded, and the areas of the four cavities of the image sequence are therefore obtained. The area change curves of the four cavities are further extracted, and the synchronous information of the four cavities is obtained. Because of the low SNR of Ultrasound images, the boundary lines of cardiac cavities are vague, so the extraction of cardiac contours is still a challenging problem. Therefore, the ASM model information is added to the traditional level set method to force the curve evolution process. According to the experimental results, the improved method improves the accuracy of the segmentation. Furthermore, based on the ventricular segmentation, the right and left ventricular systolic functions are evaluated, mainly according to the area changes. The synchronization of the four cavities of the heart is estimated based on the area changes and the volume changes.
Chou, Yi-Yu; Leporé, Natasha; Avedissian, Christina; Madsen, Sarah K.; Parikshak, Neelroop; Hua, Xue; Shaw, Leslie M.; Trojanowski, John Q.; Weiner, Michael W.; Toga, Arthur W.; Thompson, Paul M.
2009-01-01
Automated ventricular mapping with multi-atlas fluid image alignment reveals genetic effects in Alzheimer’s disease, NeuroImage 40(2): 615–630); with this method, we calculated minimal numbers of subjects needed to detect correlations between clinical scores and ventricular maps. We also assessed correlations between emerging CSF biomarkers of Alzheimer’s disease pathology and localizable deficits in the brain, in 80 AD, 80 mild cognitive impairment (MCI), and 80 healthy controls from the Alzheimer’s Disease Neuroimaging Initiative. Six expertly segmented images and their embedded parametric mesh surfaces were fluidly registered to each brain; segmentations were averaged within subjects to reduce errors. Surface-based statistical maps revealed powerful correlations between surface morphology and 4 variables: (1) diagnosis, (2) depression severity, (3) cognitive function at baseline, and (4) future cognitive decline over the following year. Cognitive function was assessed using the mini-mental state exam (MMSE), global and sum-of-boxes clinical dementia rating (CDR) scores, at baseline and 1-year follow-up. Lower CSF Aβ1–42 protein levels, a biomarker of AD pathology assessed in 138 of the 240 subjects, were correlated with lateral ventricular expansion. Using false discovery rate (FDR) methods, 40 and 120 subjects, respectively, were needed to discriminate AD and MCI from normal groups. 120 subjects were required to detect correlations between ventricular enlargement and MMSE, global CDR, sum-of-boxes CDR and clinical depression scores. Ventricular expansion maps correlate with pathological and cognitive measures in AD, and may be useful in future imaging-based clinical trials. PMID:19236926
Deng, Yan; Peng, Long; Liu, Yuan-Yuan; Yin, Li-Xue; Li, Chun-Mei; Wang, Yi; Rao, Li
2017-09-01
The aim of this prospective study was to assess the diagnosis value of four-dimensional echocardiography area strain (AS) combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis. Based on treadmill exercise load status, two-dimensional conventional echocardiography and four-dimensional echocardiography area strain were performed on patients suspected coronary artery disease before coronary angiogram. Thirty patients (case group) with mild left anterior descending coronary artery stenosis (stenosis <50%) and thirty gender- and age-matched patients (control group) without coronary artery stenosis according to the coronary angiogram results were prospectively enrolled. All the patients had no left ventricular regional wall motion abnormality in two-dimensional echocardiography at rest and exercise stress. There was no significant difference in the 16 segmental systolic peak AS at rest between two groups. After exercise stress, the peak systolic AS rest-stress at mid anterior wall (-7.00%±10.90% vs 2.80%±23.69%) and mid anterolateral wall (-4.40%±18.81% vs 8.80%±19.16%) were decreased, while increased at basal inferolateral wall (14.00%±19.27% vs -5.60%±15.94%) in case group compared with control group (P<.05). In patients with mild single vessel coronary artery stenosis, the area strain was decreased at involved segments, while compensatory increased at noninvolved segments after exercise stress. Four-dimensional echocardiography area strain combined with exercise stress echocardiography could sensitively find left ventricular regional systolic function abnormality in patients with mild single vessel coronary artery stenosis, and locate stenosis coronary artery accordingly. © 2017, Wiley Periodicals, Inc.
Albertsen, Andi Eie; Nielsen, Jens Cosedis; Poulsen, Steen Hvitfeldt; Mortensen, Peter Thomas; Pedersen, Anders Kirstein; Hansen, Peter Steen; Jensen, Henrik Kjaerulf; Egeblad, Henrik
2008-02-01
Increasing evidence from randomized trials and experimental studies indicates that right ventricular (RV) pacing may induce congestive heart failure. We studied regional left ventricular (LV) dyssynchrony and global LV function in 50 consecutive patients with sick sinus syndrome (SSS) randomized to either atrial pacing [AAI(R)] or dual chamber RV-pacing [DDD(R)]. Fifty consecutive patients were randomized to AAI(R) or DDD(R)-pacing. Tissue-Doppler imaging was used to quantify LV dyssynchrony in terms of number of segments with delayed longitudinal contraction (DLC). Left ventricular ejection fraction (LVEF) was measured using three-dimensional echocardiography. Dyssynchrony was more pronounced in the DDD(R)-group than in the AAI(R)-group at the 12 months follow-up (P < 0.05). This reflected a significant increase of dyssynchrony in the DDD(R)-group from baseline to the 12 months follow-up (1.3 +/- 1 to 2.1 +/- 1 segments displaying DLC per patient), P < 0.05. No change was observed in the AAI(R)-group (1.6 +/- 2 to 1.3 +/- 2 segments displaying DLC per patient, NS). No difference in LVEF, NYHA or NT-proBNP was observed between AAI(R)- and DDD(R)-mode after 12 months of pacing although LVEF decreased significantly in the DDD(R)-group from baseline (63.1 +/- 8%) to the 12 months follow-up (59.3 +/- 8%, P < 0.05), while LVEF remained unchanged in the AAI(R)-group (61.5 +/- 11% at baseline vs. 62.3 +/- 7% after 12 months, NS. In patients with SSS, DDD(R)-pacing but not AAI(R)-pacing induces significant LV desynchronization and reduction of LVEF.
Albertsen, Andi E; Nielsen, Jens C; Poulsen, Steen H; Mortensen, Peter T; Pedersen, Anders K; Hansen, Peter S; Jensen, Henrik K; Egeblad, Henrik
2008-03-01
We aimed to investigate whether biventricular (BiV) pacing minimizes left ventricular (LV) dyssynchrony and preserves LV ejection fraction (LVEF) as compared with standard dual-chamber DDD(R) pacing in consecutive patients with high-grade atrio-ventricular (AV) block. Fifty patients were randomized to DDD(R) pacing or BiV pacing. LVEF was measured using three-dimensional echocardiography. Tissue-Doppler imaging was used to quantify LV dyssynchrony in terms of number of segments with delayed longitudinal contraction (DLC). LVEF was not different between groups after 12 months (P = 0.18). In the DDD(R) group LVEF decreased significantly from 59.7(57.4-61.4)% at baseline to 57.2(52.1-60.6)% at 12 months of follow-up (P = 0.03), whereas LVEF remained unchanged in the BiV group [58.9(47.1-61.7)% at baseline vs. 60.1(55.2-63.3)% after 12 months (P = 0.15)]. Dyssynchrony was more prominent in the DDD(R) group than in the BiV group at baseline (2.2 +/- 2.2 vs. 1.4 +/- 1.3 segments with DLC per patient, P = 0.10); and at 12 month follow-up (1.8 +/- 1.9 vs. 0.8 +/- 0.9 segments with DLC per patient, P = 0.02). NT-proBNP was unchanged in the DDD(R) group during follow-up (122 +/- 178 pmol/L vs. 91 +/- 166 pmol/L, NS) but decreased significantly in the BiV-group (from 198 +/- 505 pmol/L to 86 +/- 95 pmol/L after 12 months, P = 0.02). BiV pacing minimizes LV dyssynchrony, preserves LV function, and reduces NT-proBNP in contrast to DDD(R) pacing in patients with high-grade AV block.
Veltman, Caroline E; Hoogslag, Georgette E; Kharbanda, Rohit K; de Graaf, Michiel A; van Zwet, Erik W; van der Hoeven, Bas L; Delgado, Victoria; Bax, Jeroen J; Scholte, Arthur J H A
2014-12-01
The presence of a left dominant coronary artery system is associated with worse outcome after ST-segment elevation myocardial infarction (STEMI) compared with right dominance or a balanced coronary artery system. However, the association between coronary arterial dominance and left ventricular (LV) function at follow-up after STEMI is unclear. The present study aimed at evaluating the relation between coronary arterial dominance and LV ejection fraction (LVEF) shortly after STEMI and at 12-month follow-up. A total of 741 patients with STEMI (mean age 60 ± 11 years and 77% men) were evaluated with 2-dimentional echocardiography within 48 hours of admission (baseline) and at 12-month follow-up after STEMI. Coronary arterial dominance was assessed on the angiographic images obtained during primary percutaneous coronary intervention. A right, left, and balanced dominant coronary artery system was noted in 640 (86%), 58 (8%), and 43 (6%) patients, respectively. At baseline, significant difference in LV function was observed, with slightly lower LVEF in patients with a left dominant coronary artery system (LVEF 45 ± 8% vs 48 ± 9% and 50 ± 9%, for left dominant, right dominant, and balanced coronary artery system respectively, p = 0.03). However, at 12-month follow-up no differences in LV function or volumes were observed among the different coronary arterial dominance groups. In conclusion, patients with a left dominant coronary artery system had lower LVEF early after STEMI. At 12-month follow-up, differences in LVEF were no longer present among the different coronary arterial dominance groups. Copyright © 2014 Elsevier Inc. All rights reserved.
Packard, René R Sevag; Baek, Kyung In; Beebe, Tyler; Jen, Nelson; Ding, Yichen; Shi, Feng; Fei, Peng; Kang, Bong Jin; Chen, Po-Heng; Gau, Jonathan; Chen, Michael; Tang, Jonathan Y; Shih, Yu-Huan; Ding, Yonghe; Li, Debiao; Xu, Xiaolei; Hsiai, Tzung K
2017-08-17
This study sought to develop an automated segmentation approach based on histogram analysis of raw axial images acquired by light-sheet fluorescent imaging (LSFI) to establish rapid reconstruction of the 3-D zebrafish cardiac architecture in response to doxorubicin-induced injury and repair. Input images underwent a 4-step automated image segmentation process consisting of stationary noise removal, histogram equalization, adaptive thresholding, and image fusion followed by 3-D reconstruction. We applied this method to 3-month old zebrafish injected intraperitoneally with doxorubicin followed by LSFI at 3, 30, and 60 days post-injection. We observed an initial decrease in myocardial and endocardial cavity volumes at day 3, followed by ventricular remodeling at day 30, and recovery at day 60 (P < 0.05, n = 7-19). Doxorubicin-injected fish developed ventricular diastolic dysfunction and worsening global cardiac function evidenced by elevated E/A ratios and myocardial performance indexes quantified by pulsed-wave Doppler ultrasound at day 30, followed by normalization at day 60 (P < 0.05, n = 9-20). Treatment with the γ-secretase inhibitor, DAPT, to inhibit cleavage and release of Notch Intracellular Domain (NICD) blocked cardiac architectural regeneration and restoration of ventricular function at day 60 (P < 0.05, n = 6-14). Our approach provides a high-throughput model with translational implications for drug discovery and genetic modifiers of chemotherapy-induced cardiomyopathy.
Transient myocardial tissue and function changes during a marathon in less fit marathon runners.
Gaudreault, Valerie; Tizon-Marcos, Helena; Poirier, Paul; Pibarot, Philippe; Gilbert, Philippe; Amyot, Marc; Rodés-Cabau, Josep; Després, Jean-Pierre; Bertrand, Olivier; Larose, Eric
2013-10-01
Although regular physical activity improves health, strenuous exercise might transiently increase cardiac risk. Training and fitness might provide protection. We prospectively studied 20 recreational marathon runners without known cardiovascular disease or symptoms: at peak training before, immediately after, and 3 months after a 42.2-km marathon. Changes in global/segmental myocardial function, edema, resting perfusion, and fibrosis were measured. At peak training, runners exercised 8.1 ± 2.3 hours and 62 ± 18 km per week with mean maximal oxygen consumption (VO2max) of 53.2 ± 8.3 mL/kg/min. In response to the marathon, global left ventricular and right ventricular ejection fraction decreased in half of the runners; these runners had poorer peak training distance, training time, and fitness level. Change in global left ventricular ejection fraction was associated with VO2max. Overall, 36% of segments developed edema, 53% decreased function, and 59% decreased perfusion. Significant agreement was observed between segment decreasing function, decreasing perfusion, and developing edema. Myocardial changes were reversible at 3 months. Completing a marathon leads to localized myocardial edema, diminished perfusion, and decreased function occurring more extensively in less trained and fit runners. Although reversible, these changes might contribute to the transient increase in cardiac risk reported during sustained vigorous exercise. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Burkett, Dale A; Slorach, Cameron; Patel, Sonali S; Redington, Andrew N; Ivy, D Dunbar; Mertens, Luc; Younoszai, Adel K; Friedberg, Mark K
2015-08-01
Through ventricular interdependence, pulmonary hypertension (PH) induces left ventricular (LV) dysfunction. We hypothesized that LV strain/strain rate, surrogate measures of myocardial contractility, are reduced in pediatric PH and relate to invasive hemodynamics, right ventricular strain, and functional measures of PH. At 2 institutions, echocardiography was prospectively performed in 54 pediatric PH patients during cardiac catheterization, and in 54 matched controls. Patients with PH had reduced LV global longitudinal strain (LS; -18.8 [-17.3 to -20.4]% versus -20.2 [-19.0 to -20.9]%; P=0.0046) predominantly because of reduced basal (-12.9 [-10.8 to -16.3]% versus -17.9 [-14.5 to -20.7]%; P<0.0001) and mid (-17.5 [-15.5 to -19.0]% versus -21.1 [-19.1 to -23.0]%; P<0.0001) septal strain. Basal global circumferential strain was reduced (-18.7 [-15.7 to -22.1]% versus -20.6 [-19.0 to -22.5]%; P=0.0098), as were septal and free-wall segments. Mid circumferential strain was reduced within the free-wall. Strain rates were reduced in similar patterns. Basal septum LS, the combined average LS of basal and mid interventricular septal segments, correlated strongly with degree of PH (r=0.66; P<0.0001), pulmonary vascular resistance (r=0.60; P<0.0001), and right ventricular free-wall LS (r=0.64; P<0.0001). Brain natriuretic peptide levels correlated moderately with septal LS (r=0.48; P=0.0038). PH functional class correlated moderately with LV free-wall LS (r=-0.48; P=0.0051). The septum, shared between ventricles and affected by septal shift, was the most affected LV region in PH. Pediatric PH patients demonstrate reduced LV strain/strain rate, predominantly within the septum, with relationships to invasive hemodynamics, right ventricular strain, and functional PH measures. © 2015 American Heart Association, Inc.
Iskandar, Muhammad Zaid; Quasem, Wahid; El-Omar, Magdi
2015-05-02
A 33-year-old man presented to hospital with acute shortness of breath and evolving ST segment changes on ECG 3 days following a cycle of 5-fluorouracil (5-FU) for colon cancer. Despite no cardiac history, subsequent echocardiogram showed severe left ventricular systolic dysfunction. The patient was initially treated with heart failure medications and his coronary angiogram was normal. Chemotherapy was stopped and he was started on nitrates and calcium channel blockers. A repeat echocardiogram and cardiac MRI a week later showed complete resolution of his left ventricular dysfunction and he was discharged home. This case report summarises 5-FU cardiotoxicity, and emphasises the importance of early recognition and correct treatment, as left ventricular systolic dysfunction in this context is potentially reversible. 2015 BMJ Publishing Group Ltd.
5-Fluorouracil cardiotoxicity: reversible left ventricular systolic dysfunction with early detection
Iskandar, Muhammad Zaid; Quasem, Wahid; El-Omar, Magdi
2015-01-01
A 33-year-old man presented to hospital with acute shortness of breath and evolving ST segment changes on ECG 3 days following a cycle of 5-fluorouracil (5-FU) for colon cancer. Despite no cardiac history, subsequent echocardiogram showed severe left ventricular systolic dysfunction. The patient was initially treated with heart failure medications and his coronary angiogram was normal. Chemotherapy was stopped and he was started on nitrates and calcium channel blockers. A repeat echocardiogram and cardiac MRI a week later showed complete resolution of his left ventricular dysfunction and he was discharged home. This case report summarises 5-FU cardiotoxicity, and emphasises the importance of early recognition and correct treatment, as left ventricular systolic dysfunction in this context is potentially reversible. PMID:25935919
NASA Astrophysics Data System (ADS)
Hatfield, Fraser N.; Dehmeshki, Jamshid
1998-09-01
Neurosurgery is an extremely specialized area of medical practice, requiring many years of training. It has been suggested that virtual reality models of the complex structures within the brain may aid in the training of neurosurgeons as well as playing an important role in the preparation for surgery. This paper focuses on the application of a probabilistic neural network to the automatic segmentation of the ventricles from magnetic resonance images of the brain, and their three dimensional visualization.
Verani, M S; Taillefer, R; Iskandrian, A E; Mahmarian, J J; He, Z X; Orlandi, C
2000-08-01
Fatty acids are the prime metabolic substrate for myocardial energy production. Hence, fatty acid imaging may be useful in the assessment of myocardial hibernation. The goal of this prospective, multicenter trial was to assess the use of a fatty acid, 123I-iodophenylpentadecanoic acid (IPPA), to identify viable, hibernating myocardium. Patients (n = 119) with abnormal left ventricular wall motion and a left ventricular ejection fraction (LVEF) < 40% who were already scheduled to undergo coronary artery bypass grafting (CABG) underwent IPPA tomography (rest and 30-min redistribution) and blood-pool radionuclide angiography within 3 d of the scheduled operation. Radionuclide angiography was repeated 6-8 wk after CABG. The study endpoint was a > or =10% increase in LVEF after CABG. The number of IPPA-viable abnormally contracting segments necessary to predict a positive LVEF outcome was determined by receiver operating characteristic (ROC) curves and was included in a logistic regression analysis, together with selected clinical variables. Before CABG, abnormal IPPA tomography findings were seen in 113 of 119 patients (95%), of whom 71 (60%) had redistribution in the 30-min images. The LVEF increased modestly after CABG (from 32% +/- 12% to 36% +/- 8%, P< 0.001).A > or =10% increase in LVEF after CABG occurred in 27 of 119 patients (23%). By ROC curves, the best predictor of a > or =10% increase in LVEF was the presence of > or =7 IPPA-viable segments (accuracy, 72%; confidence interval, 64%-80%). Among clinical and scintigraphic variables, the single most important predictor also was the number of IPPA-viable segments (P = 0.008). The number of IPPA-viable segments added significant incremental value to the best clinical predictor model. Asubstantial increase in LVEF occurs after CABG in only a minority of patients (23%) with depressed preoperative function. The number of IPPA-viable segments is useful in predicting a clinically meaningful increase in LVEF.
Chen, Wei Ren; Hu, Shun Ying; Chen, Yun Dai; Zhang, Ying; Qian, Geng; Wang, Jing; Yang, Jun Jie; Wang, Zhi Feng; Tian, Feng; Ning, Qing Xiu
2015-11-01
Several studies have shown that exenatide protects against ischemia-reperfusion injury and improves cardiac function in patients with acute ST-segment elevation myocardial infarction (STEMI). The effects of liraglutide, a glucagon-like peptide-1 analogue, on STEMI patients remain unclear. We planned to evaluate the effects of liraglutide on left ventricular function after primary percutaneous coronary intervention for STEMI. A total of 92 patients were randomized 1:1 to receive either liraglutide or placebo for 7 days. Study treatment was commenced 30 minutes before intervention (1.8 mg) and maintained for 7 days after the procedure (0.6 mg for 2 days, 1.2 mg for 2 days, followed by 1.8 mg for 3 days). Eighty-five patients completed the trial. Transthoracic echocardiography was used to assess left ventricular function. At 3 months, the primary end point, a difference in change of left ventricular ejection fraction between the two groups was +4.1% (95% CI +1.1% to +6.9%) (P < .001). There was a tendency for a lower rate of no-reflow in liraglutide group that did not reach statistical significance (7% vs control group 15%, P = .20). Liraglutide could significantly improve stress hyperglycemia (P < .05). In addition, liraglutide elicited favorable changes in markers of inflammation and endothelial function. A short 7-day course of liraglutide in STEMI patients treated with primary percutaneous coronary intervention is associated with mild improvement in left ventricular ejection fraction at 3 months. Copyright © 2015 Elsevier Inc. All rights reserved.
The New Concept of Univentricular Heart
Frescura, Carla; Thiene, Gaetano
2014-01-01
The concept of univentricular heart moved from hearts with only one ventricle connected with atria [double inlet ventricle or absent atrioventricular (AV) connection] to hearts not amenable to biventricular repair, namely hearts with two ventricles unable to sustain separately pulmonary and systemic circulations in sequence. In the latter definition, even hearts with one hypoplastic ventricle are considered “functional” univentricular hearts. They include pulmonary/aortic atresia or severe stenosis with hypoplastic ventricle, and rare conditions like huge intramural cardiac tumors and Ebstein anomaly with extreme atrialization of right ventricular cavity. In this setting, the surgical repair is univentricular with “Fontan” operation, bypassing the ventricular mass. In other words, functionally univentricular heart is a condition in which, after surgery, only one ventricle sustain systemic circulation. Univentricular hearts (double inlet or absent AV connection) almost invariably show two ventricular chambers, one main and one accessory, which lacks an inlet portion. The latter is located posteriorly when morphologically left and anteriorly when morphologically right. As far as double inlet left ventricle, this is usually associated with discordant ventriculo-arterial (VA) connection (transposition of the great arteries) and all the blood flow to the aorta, which takes origin from the hypoplastic anterior right ventricle, is ventricular septal defect (bulbo-ventricular foramen) dependent. If restrictive, an aortic arch obstruction may be present. Double inlet left ventricle may be rarely associated with VA concordance (Holmes heart). As far as double inlet right ventricle with posterior hypoplastic left ventricular cavity, ventriculo-arterial connection is usually of double outlet type; thus the term double inlet–outlet right ventricle may be coined. Absent right or left AV connection may develop in the setting of both d- or l-loop, whatever the situs. In this condition, the contra-lateral patent AV valve may be either mitral or tricuspid in terms of morphology and the underlying ventricle (main chamber) either morphologically left or right. Establishing the loop, whatever right or left (also called right or left ventricular topology), is a fundamental step in the segmental-sequential analysis of congenital heart disease. PMID:25072035
Liang, Chen; Ma, Yun; Gao, Can; Zhang, Jianhong; Yang, Min; Chen, Gen; Fu, Shan; Zhu, Tiangang
2017-02-01
The aim of this study was to investigate the change in myocardial strain in swimming athletes before and after high-intensity exercise using two-dimensional strain echocardiography (2DSE) technology. To assess whether the local and overall myocardial function and myocardial injury are accurately measured using 2DSE technology, 15 swimming athletes were selected as research objects. We applied 2DSE technology to track the 2D ultrasound images of the apical four chambers, the apical two chambers, and the apical long axis before and after high-intensity, increasing-load exercise. We recorded indices such as the left ventricular global strain (GS) and the left ventricular segmental wall longitudinal peak systolic strain (PS) in 18 systoles and analyzed the myocardial strain change before and after exercise. After high-intensity exercise, the overall myocardial strain decreased, especially the strain of the posterior wall, posterior divider, lateral wall, lower wall, and the basal and middle segments of the anterior wall. The influence of exercise on myocardial strain was greater on the basal and middle segments than on the apical segment. One-time intensive exercise negatively affected the myocardial muscle. Myocardial muscles in the apical segment and the myocardial wall were more sensitive to intensive exercise. The 2DSE technology can precisely position the motion-sensitive areas and help locate myocardial injury. © 2017, Wiley Periodicals, Inc.
Miranda, B; Pizzi, M N; Aguadé-Bruix, S; Domingo, E; Candell-Riera, J
2015-01-01
A 63-year-old male patient with a history of stent implantation in the left anterior descending three months before. Due to the presentation of vegetative symptoms, he was referred for gated-SPECT myocardial perfusion. During acquisition of the resting images he presented chest pain and ST segment elevation, so that urgent cardiac catheterization was performed, showing stent thrombosis. Rest perfusion imaging showed a defect in anterior and apical perfusion, more severe and extensive than in the stress images, with striking left ventricular dilatation and a fall in the ejection fraction related to the acute ischemia phenomenon. Intense exercise is associated with a transient activation of the coagulation system and hemodynamic changes that might induce thrombosis, especially in recently implanted coronary stents that probably still have not become completely endothelialized. Copyright © 2014 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
Fujiwara, Shohei; Komamura, Kazuo; Nakabo, Ayumi; Masaki, Mitsuru; Fukui, Miho; Sugahara, Masataka; Itohara, Kanako; Soyama, Yuko; Goda, Akiko; Hirotani, Shinichi; Mano, Toshiaki; Masuyama, Tohru
2016-02-01
Left ventricular (LV) dyssynchrony is a causal factor in LV dysfunction and thought to be associated with LV twisting motion. We tested whether three-dimensional speckle tracking (3DT) can be used to evaluate the relationship between LV twisting motion and dyssynchrony. We examined 25 patients with sick sinus syndrome who had received dual chamber pacemakers. The acute effects of ventricular pacing on LV wall motion after the switch from atrial to ventricular pacing were assessed. LV twisting motion and dyssynchrony during each pacing mode were measured using 3DT. LV dyssynchrony was calculated from the time to the minimum peak systolic area strain of 16 LV imaging segments. Ventricular pacing increased LV dyssynchrony and decreased twist and torsion. A significant correlation was observed between changes in LV dyssynchrony and changes in torsion (r = -0.65, p < 0.01). Evaluation of LV twisting motion can potentially be used for diagnosing LV dyssynchrony.
Pagnozzi, Alex M; Shen, Kaikai; Doecke, James D; Boyd, Roslyn N; Bradley, Andrew P; Rose, Stephen; Dowson, Nicholas
2016-11-01
Understanding the relationships between the structure and function of the brain largely relies on the qualitative assessment of Magnetic Resonance Images (MRIs) by expert clinicians. Automated analysis systems can support these assessments by providing quantitative measures of brain injury. However, the assessment of deep gray matter structures, which are critical to motor and executive function, remains difficult as a result of large anatomical injuries commonly observed in children with Cerebral Palsy (CP). Hence, this article proposes a robust surrogate marker of the extent of deep gray matter injury based on impingement due to local ventricular enlargement on surrounding anatomy. Local enlargement was computed using a statistical shape model of the lateral ventricles constructed from 44 healthy subjects. Measures of injury on 95 age-matched CP patients were used to train a regression model to predict six clinical measures of function. The robustness of identifying ventricular enlargement was demonstrated by an area under the curve of 0.91 when tested against a dichotomised expert clinical assessment. The measures also showed strong and significant relationships for multiple clinical scores, including: motor function (r 2 = 0.62, P < 0.005), executive function (r 2 = 0.55, P < 0.005), and communication (r 2 = 0.50, P < 0.005), especially compared to using volumes obtained from standard anatomical segmentation approaches. The lack of reliance on accurate anatomical segmentations and its resulting robustness to large anatomical variations is a key feature of the proposed automated approach. This coupled with its strong correlation with clinically meaningful scores, signifies the potential utility to repeatedly assess MRIs for clinicians diagnosing children with CP. Hum Brain Mapp 37:3795-3809, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Schreuder, Jan J; Castiglioni, Alessandro; Maisano, Francesco; Steendijk, Paul; Donelli, Andrea; Baan, Jan; Alfieri, Ottavio
2005-01-01
Surgical left ventricular restoration by means of endoventricular patch aneurysmectomy in patients with postinfarction aneurysm should result in acute improved left ventricular performance by decreasing mechanical dyssynchrony and increasing energy efficiency. Nine patients with left ventricular postinfarction aneurysm were studied intraoperatively before and after ventricular restoration with a conductance volume catheter to analyze pressure-volume relationships, energy efficiency, and mechanical dyssynchrony. The end-systolic elastance was used as a load-independent index of contractile state. Left ventricular energy efficiency was calculated from stroke work and total pressure-volume area. Segmental volume changes perpendicular to the long axis were used to calculate mechanical dyssynchrony. Statistical analysis was performed with the paired t test and least-squares linear regression. Endoventricular patch aneurysmectomy reduced end-diastolic volume by 37% (P < .001), with unchanged stroke volume. Systolic function improved, as derived from increased +dP/dt(max), by 42% (P < .03), peak ejection rate by 28% (P < .02), and ejection fraction by 16% (P < .0002). Early diastolic function improved, as shown by reduction of -dP/dt(max) by 34% (P < .006) and shortened tau by 30% (P < .001). Left ventricular end-systolic elastance increased from 1.2 +/- 0.6 to 2.2 +/- 1 mm Hg/mL (P < .001). Left ventricular energy efficiency increased by 36% (P < .002). Left ventricular mechanical dyssynchrony decreased during systole by 33% (P < .001) and during diastole by 20% (P < .005). Left ventricular restoration induced acute improvements in contractile state, energy efficiency, and relaxation, together with a decrease in left ventricular mechanical dyssynchrony.
Shamim, Shariq; McCrary, Justin; Wayne, Lori; Gratton, Matthew
2014-01-01
Background Prompt reperfusion has been shown to improve outcomes in patients with acute ST-segment elevation myocardial infarction (STEMI) with a goal of culprit vessel patency in <90 minutes. This requires a coordinated approach between the emergency medical services (EMS), emergency department (ED) and interventional cardiology. The urgency of this process can contribute to inappropriate cardiac catheterization laboratory (CCL) activations. Objectives One of the major determinants of inappropriate activations has been misinterpretation of the electrocardiogram (ECG) in the patient with acute chest pain. Methods We report the ECG findings for all CCL activations over an 18-month period after the inception of a STEMI program at our institution. Results There were a total of 139 activations with 77 having a STEMI diagnosis confirmed and 62 activations where there was no STEMI. The inappropriate activations resulted from a combination of atypical symptoms and misinterpretation of the ECG (45% due to anterior ST-segment elevation) on patient presentation. The electrocardiographic abnormalities were particularly problematic in African-Americans with left ventricular hypertrophy. Conclusions In this single-center, prospective observational study, nearly half of the inappropriate STEMI activations were due to the misinterpretation of anterior ST-segment elevation and this finding was commonly seen in African-Americans with left ventricular hypertrophy. PMID:25009790
WEB downloadable software for training in cardiovascular hemodynamics in the (3-D) stress echo lab
2010-01-01
When a physiological (exercise) stress echo is scheduled, interest focuses on wall motion segmental contraction abnormalities to diagnose ischemic response to stress, and on left ventricular ejection fraction to assess contractile reserve. Echocardiographic evaluation of volumes (plus standard assessment of heart rate and blood pressure) is ideally suited for the quantitative and accurate calculation of a set of parameters allowing a complete characterization of cardiovascular hemodynamics (including cardiac output and systemic vascular resistance), left ventricular elastance (mirroring left ventricular contractility, theoretically independent of preload and afterload changes heavily affecting the ejection fraction), arterial elastance, ventricular arterial coupling (a central determinant of net cardiovascular performance in normal and pathological conditions), and diastolic function (through the diastolic mean filling rate). All these parameters were previously inaccessible, inaccurate or labor-intensive and now become, at least in principle, available in the stress echocardiography laboratory since all of them need an accurate estimation of left ventricular volumes and stroke volume, easily derived from 3 D echo. Aims of this paper are: 1) to propose a simple method to assess a set of parameters allowing a complete characterization of cardiovascular hemodynamics in the stress echo lab, from basic measurements to calculations 2) to propose a simple, web-based software program, to learn and training calculations as a phantom of the everyday activity in the busy stress echo lab 3) to show examples of software testing in a way that proves its value. The informatics infrastructure is available on the web, linking to http://cctrainer.ifc.cnr.it PMID:21073738
Shimizu, Wataru
2010-01-01
This review article sought to describe patterns of repolarization on the surface electrocardiogram in inherited cardiac arrhythmias and to discuss how the knowledge of genetic makeup and cellular data can affect the analysis based on the data derived from the experimental studies using arterially perfused canine ventricular wedge preparations. Molecular genetic studies have established a link between a number of inherited cardiac arrhythmia syndromes and mutations in genes encoding cardiac ion channels or membrane components during the past 2 decades. Twelve forms of congenital long QT syndrome have been so far identified, and genotype-phenotype correlations have been investigated especially in the 3 major genotypes-LQT1, LQT2, and LQT3. Abnormal T waves are reported in the LQT1, LQT2, and LQT3, and the differences in the time course of repolarization of the epicardial, midmyocardial, and endocardial cells give rise to voltage gradients responsible for the manifestation of phenotypic appearance of abnormal T waves. Brugada syndrome is characterized by ST-segment elevation in leads V1 to V3 and an episode of ventricular fibrillation, in which 7 genotypes have been reported. An intrinsically prominent transient outward current (I(to))-mediated action potential notch and a subsequent loss of action potential dome in the epicardium, but not in the endocardium of the right ventricular outflow tract, give rise to a transmural voltage gradient, resulting in ST-segment elevation, and a subsequent phase 2 reentry-induced ventricular fibrillation. In conclusion, transmural electrical heterogeneity of repolarization across the ventricular wall profoundly affects the phenotypic manifestation of repolarization patterns on the surface electrocardiogram in inherited cardiac arrhythmias. Copyright © 2010 Elsevier Inc. All rights reserved.
Influence of the hole geometry on the flow distribution in ventricular catheters for hydrocephalus.
Giménez, Ángel; Galarza, Marcelo; Pellicer, Olga; Valero, José; Amigó, José M
2016-07-15
Hydrocephalus is a medical condition consisting of an abnormal accumulation of cerebrospinal fluid within the brain. A catheter is inserted in one of the brain ventricles and then connected to an external valve to drain the excess of cerebrospinal fluid. The main drawback of this technique is that, over time, the ventricular catheter ends up getting blocked by the cells and macromolecules present in the cerebrospinal fluid. A crucial factor influencing this obstruction is a non-uniform flow pattern through the catheter, since it facilitates adhesion of suspended particles to the walls. In this paper we focus on the effects that tilted holes as well as conical holes have on the flow distribution and shear stress. We have carried out 3D computational simulations to study the effect of the hole geometry on the cerebrospinal fluid flow through ventricular catheters. All the simulations were done with the OpenFOAM® toolbox. In particular, three different groups of models were investigated by varying (i) the tilt angles of the holes, (ii) the inner and outer diameters of the holes, and (iii) the distances between the so-called hole segments. The replacement of cylindrical holes by conical holes was found to have a strong influence on the flow distribution and to lower slightly the shear stress. Tilted holes did not involve flow distribution changes when the hole segments are sufficiently separated, but the mean shear stress was certainly reduced. The authors present new results about the behavior of the fluid flow through ventricular catheters. These results complete earlier work on this topic by adding the influence of the hole geometry. The overall objective pursued by this research is to provide guidelines to improve existing commercially available ventricular catheters.
Yaksh, Ameeta; Kik, Charles; Knops, Paul; Zwiers, Korinne; van Ettinger, Maarten J B; Manintveld, Olivier C; de Wijs, Marcel C J; van der Kemp, Peter; Bogers, Ad J J C; de Groot, Natasja M S
2016-07-08
Early postoperative ventricular tachyarrhythmia (PoVT) after left ventricular assist device (LVAD) implantation are common and associated with higher mortality-rates. At present, there is no data on initiation of these PoVT and the role of alterations in cardiac hemodynamics. A LVAD was implanted in a patient with end-stage heart failure due to a ischemic cardiomyopathy. Alterations in cardiac rhythm and hemodynamics preceding PoVT-episodes during the first five postoperative days were examined by using continuous recordings of cardiac rhythm and various hemodynamic parameters. All PoVT (N=120) were monomorphic, most often preceded by short-long-short-sequences or regular SR and initiated by ventricular runs. Prior to PoVT, mean arterial pressure decreased; heart rate and ST-segments deviations increased. PoVT are caused by different underlying electrophysiological mechanisms. Yet, they are all monomorphic and preceded by hemodynamic deterioration due to myocardial ischemia.
Investigating structural brain changes of dehydration using voxel-based morphometry.
Streitbürger, Daniel-Paolo; Möller, Harald E; Tittgemeyer, Marc; Hund-Georgiadis, Margret; Schroeter, Matthias L; Mueller, Karsten
2012-01-01
Dehydration can affect the volume of brain structures, which might imply a confound in volumetric and morphometric studies of normal or diseased brain. Six young, healthy volunteers were repeatedly investigated using three-dimensional T(1)-weighted magnetic resonance imaging during states of normal hydration, hyperhydration, and dehydration to assess volume changes in gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF). The datasets were analyzed using voxel-based morphometry (VBM), a widely used voxel-wise statistical analysis tool, FreeSurfer, a fully automated volumetric segmentation measure, and SIENAr a longitudinal brain-change detection algorithm. A significant decrease of GM and WM volume associated with dehydration was found in various brain regions, most prominently, in temporal and sub-gyral parietal areas, in the left inferior orbito-frontal region, and in the extra-nuclear region. Moreover, we found consistent increases in CSF, that is, an expansion of the ventricular system affecting both lateral ventricles, the third, and the fourth ventricle. Similar degrees of shrinkage in WM volume and increase of the ventricular system have been reported in studies of mild cognitive impairment or Alzheimer's disease during disease progression. Based on these findings, a potential confound in GM and WM or ventricular volume studies due to the subjects' hydration state cannot be excluded and should be appropriately addressed in morphometric studies of the brain.
Investigating Structural Brain Changes of Dehydration Using Voxel-Based Morphometry
Streitbürger, Daniel-Paolo; Möller, Harald E.; Tittgemeyer, Marc; Hund-Georgiadis, Margret; Schroeter, Matthias L.; Mueller, Karsten
2012-01-01
Dehydration can affect the volume of brain structures, which might imply a confound in volumetric and morphometric studies of normal or diseased brain. Six young, healthy volunteers were repeatedly investigated using three-dimensional T 1-weighted magnetic resonance imaging during states of normal hydration, hyperhydration, and dehydration to assess volume changes in gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF). The datasets were analyzed using voxel-based morphometry (VBM), a widely used voxel-wise statistical analysis tool, FreeSurfer, a fully automated volumetric segmentation measure, and SIENAr a longitudinal brain-change detection algorithm. A significant decrease of GM and WM volume associated with dehydration was found in various brain regions, most prominently, in temporal and sub-gyral parietal areas, in the left inferior orbito-frontal region, and in the extra-nuclear region. Moreover, we found consistent increases in CSF, that is, an expansion of the ventricular system affecting both lateral ventricles, the third, and the fourth ventricle. Similar degrees of shrinkage in WM volume and increase of the ventricular system have been reported in studies of mild cognitive impairment or Alzheime s disease during disease progression. Based on these findings, a potential confound in GM and WM or ventricular volume studies due to the subjects’ hydration state cannot be excluded and should be appropriately addressed in morphometric studies of the brain. PMID:22952926
Arrighi, James A; Burg, Matthew; Cohen, Ira S; Soufer, Robert
2003-01-01
Mental stress (MS) is an important provocateur of myocardial ischemia in many patients with chronic coronary artery disease. The majority of laboratory assessments of ischemia in response to MS have included measurements of either myocardial perfusion or function alone. We performed this study to determine the relationship between alterations in perfusion and ventricular function during MS. Methods and results Twenty-eight patients with reversible perfusion defects on exercise or pharmacologic stress myocardial perfusion imaging (MPI) underwent simultaneous technetium 99m sestamibi single photon emission computed tomography (SPECT) MPI and transthoracic echocardiography at rest and during MS according to a mental arithmetic protocol. In all cases the MS study was performed within 4 weeks of the initial exercise or pharmacologic MPI that demonstrated ischemia. SPECT studies were analyzed visually with the use of a 13-segment model and quantitatively by semiautomated circumferential profile analysis. Echocardiograms were graded on a segmental model for regional wall motion on a 4-point scale. Of 28 patients, 18 (64%) had perfusion defects and/or left ventricular dysfunction develop during MS: 9 (32%) had myocardial perfusion defects develop, 6 (21%) had regional or global left ventricular dysfunction develop, and 3 (11%) had both perfusion defects and left ventricular dysfunction develop. The overall concordance between perfusion and function criteria for ischemia during MS was only 46%. Among 9 patients with MS-induced left ventricular dysfunction, 5 had new regional wall motion abnormalities and 4 had a global decrement in function. In patients with MS-induced ischemia by SPECT, the number of reversible perfusion defects was similar during both MS and exercise/pharmacologic stress (2.8 +/- 2.0 vs 3.5 +/- 1.8, P =.41). Hemodynamic changes during MS were similar whether patients were divided on the basis of perfusion defects or left ventricular dysfunction during MS. These data indicate the feasibility of simultaneous assessment of perfusion and function responses during MS. Flow and function responses to MS are frequently not concordant. These data suggest that MS-induced changes in perfusion may represent a different phenomenon than MS-induced changes in left ventricular function (either globally or regionally).
Cabani, Enrico; Lattanzi, Fabio; Paci, Anna Maria; Pieroni, Andrea; Baria, Luca; Tommasi, Salvatore Mario De
2009-04-01
Late complications after pharmacological stress echocardiography are infrequent but potentially dreadful events. We report the case of a 80-year-old woman admitted to hospital for rest chest pain with trivial troponin increase, normal left ventricular function and no significant ECG changes. A dobutamine stress echocardiography was performed for diagnostic purpose, with a negative result. About 30 min after the end of dobutamine infusion, she developed ST-segment elevation in inferior leads associated with chest pain and left ventricular dyssynergy, promptly resolved by sublingual nitrates. Subsequently, angiography documented the absence of significant coronary stenoses. The following clinical course was uneventful. Transient myocardial ischemia was likely due to dobutamine-induced coronary spasm. The case emphasizes the utility of routine, long-lasting monitoring of patients after stress echocardiography, even if negative, to counteract possible late life-threatening complications.
Zheng, Yefeng; Barbu, Adrian; Georgescu, Bogdan; Scheuering, Michael; Comaniciu, Dorin
2008-11-01
We propose an automatic four-chamber heart segmentation system for the quantitative functional analysis of the heart from cardiac computed tomography (CT) volumes. Two topics are discussed: heart modeling and automatic model fitting to an unseen volume. Heart modeling is a nontrivial task since the heart is a complex nonrigid organ. The model must be anatomically accurate, allow manual editing, and provide sufficient information to guide automatic detection and segmentation. Unlike previous work, we explicitly represent important landmarks (such as the valves and the ventricular septum cusps) among the control points of the model. The control points can be detected reliably to guide the automatic model fitting process. Using this model, we develop an efficient and robust approach for automatic heart chamber segmentation in 3-D CT volumes. We formulate the segmentation as a two-step learning problem: anatomical structure localization and boundary delineation. In both steps, we exploit the recent advances in learning discriminative models. A novel algorithm, marginal space learning (MSL), is introduced to solve the 9-D similarity transformation search problem for localizing the heart chambers. After determining the pose of the heart chambers, we estimate the 3-D shape through learning-based boundary delineation. The proposed method has been extensively tested on the largest dataset (with 323 volumes from 137 patients) ever reported in the literature. To the best of our knowledge, our system is the fastest with a speed of 4.0 s per volume (on a dual-core 3.2-GHz processor) for the automatic segmentation of all four chambers.
Double hazards of ischemia and reperfusion arrhythmias in a patient with variant angina pectoris.
Xu, Mingzhu; Yang, Xiangjun
2015-01-01
Variant angina pectoris, also called Prinzmetal's angina, is a syndrome caused by vasospasms of the coronary arteries. It can lead to myocardial infarction, ventricular arrhythmias, atrioventricular block and even sudden cardiac death. We report the case of a 53 year-old male patient with recurrent episodes of chest pain and arrhythmias in the course of related variant angina pectoris. It is likely that the reperfusion following myocardial ischemia was responsible for the ventricular fibrillation while the ST-segment returned to the baseline. This case showed that potential lethal arrhythmias could arise due to variant angina pectoris. It also indicated that ventricular fibrillation could be self-terminated. Copyright © 2015 Elsevier Inc. All rights reserved.
Power, Alyssa; Poonja, Sabrina; Disler, Dal; Myers, Kimberley; Patton, David J; Mah, Jean K; Fine, Nowell M; Greenway, Steven C
2017-01-01
Advances in medical care for patients with Duchenne muscular dystrophy (DMD) have resulted in improved survival and an increased prevalence of cardiomyopathy. Serial echocardiographic surveillance is recommended to detect early cardiac dysfunction and initiate medical therapy. Clinical anecdote suggests that echocardiographic quality diminishes over time, impeding accurate assessment of left ventricular systolic function. Furthermore, evidence-based guidelines for the use of cardiac imaging in DMD, including cardiac magnetic resonance imaging (CMR), are limited. The objective of our single-center, retrospective study was to quantify the deterioration in echocardiographic image quality with increasing patient age and identify an age at which CMR should be considered. We retrospectively reviewed and graded the image quality of serial echocardiograms obtained in young patients with DMD. The quality of 16 left ventricular segments in two echocardiographic views was visually graded using a binary scoring system. An endocardial border delineation percentage (EBDP) score was calculated by dividing the number of segments with adequate endocardial delineation in each imaging window by the total number of segments present in that window and multiplying by 100. Linear regression analysis was performed to model the relationship between the EBDP scores and patient age. Fifty-five echocardiograms from 13 patients (mean age 11.6 years, range 3.6-19.9) were systematically reviewed. By 13 years of age, 50% of the echocardiograms were classified as suboptimal with ≥30% of segments inadequately visualized, and by 15 years of age, 78% of studies were suboptimal. Linear regression analysis revealed a negative correlation between patient age and EBDP score ( r = -2.49, 95% confidence intervals -4.73, -0.25; p = 0.032), with the score decreasing by 2.5% for each 1 year increase in age. Echocardiographic image quality declines with increasing age in DMD. Alternate imaging modalities may play a role in cases of poor echocardiographic image quality.
2014-01-01
Since cell membranes are weak sources of electrostatic fields, this ECG interpretation relies on the analogy between cells and electrets. It is here assumed that cell-bound electric fields unite, reach the body surface and the surrounding space and form the thoracic electric field that consists from two concentric structures: the thoracic wall and the heart. If ECG leads measure differences in electric potentials between skin electrodes, they give scalar values that define position of the electric field center along each lead. Repolarised heart muscle acts as a stable positive electric source, while depolarized heart muscle produces much weaker negative electric field. During T-P, P-R and S-T segments electric field is stable, only subtle changes are detectable by skin electrodes. Diastolic electric field forms after ventricular depolarization (T-P segments in the ECG recording). Telediastolic electric field forms after the atria have been depolarized (P-Q segments in the ECG recording). Systolic electric field forms after the ventricular depolarization (S-T segments in the ECG recording). The three ECG waves (P, QRS and T) can then be described as unbalanced transitions of the heart electric field from one stable configuration to the next and in that process the electric field center is temporarily displaced. In the initial phase of QRS, the rapidly diminishing septal electric field makes measured potentials dependent only on positive charges of the corresponding parts of the left and the right heart that lie within the lead axes. If more positive charges are near the "DOWN" electrode than near the "UP" electrode, a Q wave will be seen, otherwise an R wave is expected. Repolarization of the ventricular muscle is dampened by the early septal muscle repolarization that reduces deflection of T waves. Since the "UP" electrode of most leads is near the usually larger left ventricle muscle, T waves are in these leads positive, although of smaller amplitude and longer duration than the QRS wave in the same lead. The proposed interpretation is applied to bundle branch blocks, fascicular (hemi-) blocks and changes during heart muscle ischemia. PMID:24506945
Salemi, Vera Maria Cury; Fernandes, Fabio; Sirvente, Raquel; Nastari, Luciano; Rosa, Leonardo Vieira; Ferreira, Cristiano A; Pena, José Luiz Barros; Picard, Michael H; Mady, Charles
2009-01-01
We compared left ventricular regional wall motion, the global left ventricular ejection fraction, and the New York Heart Association functional class pre- and postoperatively. Endomyocardial fibrosis is characterized by fibrous tissue deposition in the endomyocardium of the apex and/or inflow tract of one or both ventricles. Although left ventricular global systolic function is preserved, patients exhibit wall motion abnormalities in the apical and inferoapical regions. Fibrous tissue resection in New York Heart Association FC III and IV endomyocardial fibrosis patients has been shown to decrease morbidity and mortality. We prospectively studied 30 patients (20 female, 30+/-10 years) before and 5+/-8 months after surgery. The left ventricular ejection fraction was determined using the area-length method. Regional left ventricular motion was measured by the centerline method. Five left ventricular segments were analyzed pre- and postoperatively. Abnormality was expressed in units of standard deviation from the mean motion in a normal reference population. Left ventricular wall motion in the five regions did not differ between pre- and postoperative measurements. Additionally, the left ventricular ejection fraction did not change after surgery (0.45+/-0.13% x 0.43+/-0.12% pre- and postoperatively, respectively). The New York Heart Association functional class improved to class I in 40% and class II in 43% of patients postoperatively (p<0.05). Although endomyocardial fibrosis patients have improved clinical symptoms after surgery, the global left ventricular ejection fraction and regional wall motion in these patients do not change. This finding suggests that other explanations, such as improvements in diastolic function, may be operational.
Sanz-de la Garza, Maria; Rubies, Cira; Batlle, Montserrat; Bijnens, Bart H; Mont, Lluis; Sitges, Marta; Guasch, Eduard
2017-09-01
Arrhythmogenic right ventricular (RV) remodeling has been reported in response to regular training, but it remains unclear how exercise intensity affects the presence and extent of such remodeling. We aimed to assess the relationship between RV remodeling and exercise load in a long-term endurance training model. Wistar rats were conditioned to run at moderate (MOD; 45 min, 30 cm/s) or intense (INT; 60 min, 60 cm/s) workloads for 16 wk; sedentary rats served as controls. Cardiac remodeling was assessed with standard echocardiographic and tissue Doppler techniques, sensor-tip pressure catheters, and pressure-volume loop analyses. After MOD training, both ventricles similarly dilated (~16%); the RV apical segment deformation, but not the basal segment deformation, was increased [apical strain rate (SR): -2.9 ± 0.5 vs. -3.3 ± 0.6 s -1 , SED vs. MOD]. INT training prompted marked RV dilatation (~26%) but did not further dilate the left ventricle (LV). A reduction in both RV segments' deformation in INT rats (apical SR: -3.3 ± 0.6 vs. -3.0 ± 0.4 s -1 and basal SR: -3.3 ± 0.7 vs. -2.7 ± 0.6 s -1 , MOD vs. INT) led to decreased global contractile function (maximal rate of rise of LV pressure: 2.53 ± 0.15 vs. 2.17 ± 0.116 mmHg/ms, MOD vs. INT). Echocardiography and hemodynamics consistently pointed to impaired RV diastolic function in INT rats. LV systolic and diastolic functions remained unchanged in all groups. In conclusion, we showed a biphasic, unbalanced RV remodeling response with increasing doses of exercise: physiological adaptation after MOD training turns adverse with INT training, involving disproportionate RV dilatation, decreased contractility, and impaired diastolic function. Our findings support the existence of an exercise load threshold beyond which cardiac remodeling becomes maladaptive. NEW & NOTEWORTHY Exercise promotes left ventricular eccentric hypertrophy with no changes in systolic or diastolic function in healthy rats. Conversely, right ventricular adaptation to physical activity follows a biphasic, dose-dependent, and segmentary pattern. Moderate exercise promotes a mild systolic function enhancement at the right ventricular apex and more intense exercise impairs systolic and diastolic function. Copyright © 2017 the American Physiological Society.
Paraskevaidis, I A; Kremastinos, D T; Kassimatis, A S; Karavolias, G K; Kordosis, G D; Kyriakides, Z S; Toutouzas, P K
1993-01-01
OBJECTIVE--To determine whether an abnormal response of diastolic blood pressure during treadmill exercise stress testing correlated with the number of obstructed vessels and with left ventricular systolic function in patients with coronary artery disease. DESIGN--Diastolic blood pressure was measured invasively during exercise stress testing and coronary angiograms and left ventriculograms were obtained at rest in patients with coronary artery disease. The abnormal (> or = 15 mm Hg) diastolic blood pressure response was compared with the number of obstructed coronary arteries and with left ventricular systolic function. SETTING--Two tertiary referral centres. PATIENTS--50 consecutive patients (mean age 57 years) with coronary artery disease. MAIN OUTCOME MEASURES--The increase in diastolic blood pressure during exercise and its correlation with the appearance and disappearance of ST segment deviation, resting left ventricular systolic function, and the number of obstructed coronary arteries. RESULTS--Group 1: 10 (20%) patients (three with one, four with two, and three with three vessel coronary artery disease) (mean (SD) age 54.7 (12) years) had an abnormal diastolic blood pressure response that appeared 1.2 (0.3) min before ST segment deviation and became normal 0.9 (0.3) min after the ST segment returned to normal. Group 2: 40 (80%) patients (12 with one, 16 with two, and 12 with three vessel coronary arteries disease) (aged 56.8 (8.2) years) had a normal diastolic blood pressure response to stress testing. The ejection fraction (46.3 (5)%) and cardiac index (2.6 (0.1) 1/min/m2) in group 1 were less than in group 2 (61.6 (4.2)% and 3.8 (0.3) 1/min/m2 respectively, p < or = 0.001). The end systolic volume was greater in group 1 than in group 2: 38.7 (0.7 ml/m2 v 28.2 (2.1) ml/m2, p < or = 0.001. CONCLUSION--In patients with coronary artery disease an abnormal increase in diastolic blood pressure during exercise stress testing correlated well with left ventricular systolic function at rest but not with the number of obstructed coronary arteries. The abnormal response of diastolic blood pressure probably reflects deterioration of myocardial function. Images PMID:8343317
Levy, Philip T; El-Khuffash, Afif; Patel, Meghna D; Breatnach, Colm R; James, Adam T; Sanchez, Aura A; Abuchabe, Cristina; Rogal, Sarah R; Holland, Mark R; McNamara, Patrick J; Jain, Amish; Franklin, Orla; Mertens, Luc; Hamvas, Aaron; Singh, Gautam K
2017-07-01
The aim of this study was to determine the maturational changes in systolic ventricular strain mechanics by two-dimensional speckle-tracking echocardiography in extremely preterm neonates from birth to 1 year of age and discern the impact of common cardiopulmonary abnormalities on the deformation measures. In a prospective multicenter study of 239 extremely preterm infants (<29 weeks gestation at birth), left ventricular (LV) global longitudinal strain (GLS) and global longitudinal systolic strain rate (GLSRs), interventricular septal wall (IVS) GLS and GLSRs, right ventricular (RV) free wall longitudinal strain and strain rate, and segmental longitudinal strain in the RV free wall, LV free wall, and IVS were serially measured on days 1, 2, and 5 to 7, at 32 and 36 weeks postmenstrual age, and at 1 year corrected age (CA). Premature infants who developed bronchopulmonary dysplasia or had echocardiographic findings of pulmonary hypertension were analyzed separately. In uncomplicated preterm infants (n = 103 [48%]), LV GLS and GLSRs remained unchanged from days 5 to 7 to 1 year CA (P = .60 and P = .59). RV free wall longitudinal strain, RV free wall longitudinal strain rate, and IVS GLS and GLSRs significantly increased over the same time period (P < .01 for all measures). A significant base-to-apex (highest to lowest) segmental longitudinal strain gradient (P < .01) was seen in the RV free wall and a reverse apex-to-base gradient (P < .01) in the LV free wall. In infants with bronchopulmonary dysplasia and/or pulmonary hypertension (n = 119 [51%]), RV free wall longitudinal strain and IVS GLS were significantly lower (P < .01), LV GLS and GLSRs were similar (P = .56), and IVS segmental longitudinal strain persisted as an RV-dominant base-to-apex gradient from 32 weeks postmenstrual age to 1 year CA. This study tracks the maturational patterns of global and regional deformation by two-dimensional speckle-tracking echocardiography in extremely preterm infants from birth to 1 year CA. The maturational patterns are ventricular specific. Bronchopulmonary dysplasia and pulmonary hypertension leave a negative impact on RV and IVS strain, while LV strain remains stable. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsoumakidou, Georgia, E-mail: gtsoumakidou@yahoo.com; Buy, Xavier, E-mail: Xavier.buy@chru-strasbourg.f; Zickler, Pierre, E-mail: pierre.zickler@chru-strasbourg.f
2010-06-15
A rare life-threatening complication during percutaneous cryoablation of an adrenal gland metastasis from a lung carcinoma is reported. The patient presented hypertensive crisis at the beginning of the thawing cycle, followed by electrocardiographic change which necessitated interruption of the procedure and his transfer to the intensive care unit with suspicion of heart infarct. There was a slight increase in cardiac enzyme levels, and ventricular angiography demonstrated transient hypokinesis-dyskinesis of the mid left ventricular segments without apical involvement, while the coronary arteries showed no significant stenosis on coronarography. These findings led to the diagnosis of Takotsubo cardiomyopathy left ventricular dysfunction syndrome.more » This is the first case of Takotsubo cardiomyopathy occurring as a complication during percutaneous ablation of an adrenal gland tumor.« less
2013-01-01
Background T2-weighted cardiovascular magnetic resonance (CMR) is clinically-useful for imaging the ischemic area-at-risk and amount of salvageable myocardium in patients with acute myocardial infarction (MI). However, to date, quantification of oedema is user-defined and potentially subjective. Methods We describe a highly automatic framework for quantifying myocardial oedema from bright blood T2-weighted CMR in patients with acute MI. Our approach retains user input (i.e. clinical judgment) to confirm the presence of oedema on an image which is then subjected to an automatic analysis. The new method was tested on 25 consecutive acute MI patients who had a CMR within 48 hours of hospital admission. Left ventricular wall boundaries were delineated automatically by variational level set methods followed by automatic detection of myocardial oedema by fitting a Rayleigh-Gaussian mixture statistical model. These data were compared with results from manual segmentation of the left ventricular wall and oedema, the current standard approach. Results The mean perpendicular distances between automatically detected left ventricular boundaries and corresponding manual delineated boundaries were in the range of 1-2 mm. Dice similarity coefficients for agreement (0=no agreement, 1=perfect agreement) between manual delineation and automatic segmentation of the left ventricular wall boundaries and oedema regions were 0.86 and 0.74, respectively. Conclusion Compared to standard manual approaches, the new highly automatic method for estimating myocardial oedema is accurate and straightforward. It has potential as a generic software tool for physicians to use in clinical practice. PMID:23548176
Szél, Tamás; Koncz, István; Antzelevitch, Charles
2013-01-01
Background: Brugada syndrome is an inherited disease associated with vulnerability to ventricular tachycardia and sudden cardiac death in young adults. Milrinone and cilostazol, oral phosphodiesterase (PDE) type III inhibitors, have been shown to increase ICa and modestly increase heart rate by elevating the level of intracellular cyclic AMP. Objective: The present study examines the effectiveness of these PDE inhibitors to suppress arrhythmogenesis in an experimental model of Brugada syndrome. Methods: Action potential (AP) and ECG recordings were obtained from epicardial and endocardial sites of coronary-perfused canine right ventricular wedge preparations. The Ito agonist NS5806 (5 μM) and Ca2+ channel blocker verapamil (2 μM) were used to pharmacologically mimic Brugada phenotype. Results: The combination induced all-or-none repolarization at some epicardial sites but not others, leading to ST-segment elevation as well as an increase in both epicardial and transmural dispersion of repolarization. Under these conditions, phase 2 reentry developed as the epicardial AP dome propagated from sites where it was maintained to sites at which it was lost, generating closely coupled extrasystoles and ventricular tachycardia. Addition of the PDE inhibitor milrinone (2.5 μM) or cilostazol (5-10 μM) to the coronary perfusate restored the epicardial AP dome, reduced dispersion and abolished phase 2 reentry—induced extrasystoles and ventricular tachycardia. Conclusions: Our study identifies milrinone as a more potent alternative to cilostazol for reversing the repolarization defects responsible for the electrocardiographic and arrhythmic manifestations of Brugada syndrome. Both drugs normalize ST segment elevation, and suppress arrhythmogenesis in experimental models of Brugada syndrome. PMID:23911896
Haapaniemi, Susan; Franklin, Barry A; Wegner, James H; Hamar, Shelby; Gordon, Seymour; Timmis, Gerald C; O'Neill, William W
2007-07-15
To evaluate the cardiac demands of hunting deer, continuous ambulatory electrocardiograms were obtained in men with and without coronary artery disease (CAD) and compared with their responses to maximal treadmill testing. A volunteer sample of 25 middle-aged men (mean +/- SD 55 +/- 7 years of age), 17 of whom had known CAD, completed the study. Peak heart rate (HR) during 7 different deer hunting activities was expressed as the mean percentage of the maximal HR (HRmax) attained during treadmill testing. Periods of sustained sinus tachycardia were identified. Arrhythmias and ST-segment depression during deer hunting that were not apparent during treadmill testing were documented. Overall, 22 of 25 subjects demonstrated HR responses >85% HRmax for 1 to 65 minutes. Ten subjects exceeded the HRmax achieved during treadmill testing for 1 to 5 minutes. The relative HR response during ambulatory activity in the field was inversely related to cardiorespiratory fitness, expressed as METs (r = -0.59; p = 0.0020). Three subjects had ischemic electrocardiograms during deer hunting, but not during treadmill testing. Complex arrhythmias in the field not detected by treadmill testing included ventricular bi-trigeminy, ventricular couplets, and 8 runs of ventricular tachycardia (3 to 28 beats) in 3 subjects with documented CAD. In conclusion, deer hunting can evoke sustained HRs, ischemic ST-segment depression, and threatening ventricular arrhythmias in excess of those documented during maximal treadmill testing. The strenuous nature of deer hunting coupled with presumed hyperadrenergia and superimposed environmental stresses may contribute to the excessive cardiac demands associated with this activity.
Maciel, Bruno Araújo; Cidrão, Alan Alves de Lima; Sousa, Italo Bruno Dos Santos; Ferreira, José Adailson da Silva; Messias Neto, Valdevino Pedro
2013-03-01
Takotsubo syndrome is characterized by predominantly medial-apical transient left ventricular dysfunction, which is typically triggered by physical or emotional stress. The present article reports the case of a 61-year-old female patient presenting with dizziness, excessive sweating, and sudden state of ill feeling following an episode involving intense emotional stress. The physical examination and electrocardiogram were normal upon admission, but the troponin I and creatine kinase-MB concentrations were increased. Acute myocardial infarction without ST segment elevation was suspected, and coronary angiography was immediately performed, which showed severe diffuse left ventricular hypokinesia, medial-apical systolic ballooning, and a lack of significant coronary injury. The patient was referred to the intensive care unit and was successfully treated with supportive therapy. As this case shows, Takotsubo syndrome might simulate the clinical manifestations of acute myocardial infarction, and coronary angiography is necessary to distinguish between both myocardial infarction and myocardial infarction in the acute stage. The present patient progressed with spontaneous resolution of the ventricular dysfunction without any sequelae.
Maciel, Bruno Araújo; Cidrão, Alan Alves de Lima; Sousa, Ítalo Bruno dos Santos; Ferreira, José Adailson da Silva; Messias Neto, Valdevino Pedro
2013-01-01
Takotsubo syndrome is characterized by predominantly medial-apical transient left ventricular dysfunction, which is typically triggered by physical or emotional stress. The present article reports the case of a 61-year-old female patient presenting with dizziness, excessive sweating, and sudden state of ill feeling following an episode involving intense emotional stress. The physical examination and electrocardiogram were normal upon admission, but the troponin I and creatine kinase-MB concentrations were increased. Acute myocardial infarction without ST segment elevation was suspected, and coronary angiography was immediately performed, which showed severe diffuse left ventricular hypokinesia, medial-apical systolic ballooning, and a lack of significant coronary injury. The patient was referred to the intensive care unit and was successfully treated with supportive therapy. As this case shows, Takotsubo syndrome might simulate the clinical manifestations of acute myocardial infarction, and coronary angiography is necessary to distinguish between both myocardial infarction and myocardial infarction in the acute stage. The present patient progressed with spontaneous resolution of the ventricular dysfunction without any sequelae. PMID:23887762
Hallbergson, Anna; Esch, Jesse J; Tran, Trang X; Lock, James E; Marshall, Audrey C
2016-10-01
We have taken a novel approach using oral rapamycin - sirolimus - as a medical adjunct to percutaneous therapy in patients with in-stent stenosis and high risk of right ventricular failure. Peripheral pulmonary artery stenosis can result in right ventricular hypertension, dysfunction, and death. Percutaneous pulmonary artery angioplasty and stent placement acutely relieve obstructions, but patients frequently require re-interventions due to re-stenosis. In patients with tetralogy of Fallot or arteriopathy, the problem of in-stent stenosis contributes to the rapidly recurrent disease. Rapamycin was administered to 10 patients (1.5-18 years) with peripheral pulmonary stenosis and in-stent stenosis and either right ventricular hypertension, pulmonary blood flow maldistribution, or segmental pulmonary hypertension. Treatment was initiated around the time of catheterisation and continued for 1-3 months. Potential side-effects were monitored by clinical review and blood tests. Target serum rapamycin level (6-10 ng/ml) was accomplished in all patients; eight of the nine patients who returned for clinically indicated catheterisations demonstrated reduction in in-stent stenosis, and eight of the 10 patients experienced no significant side-effects. Among all, one patient developed diarrhoea requiring drug discontinuation, and one patient experienced gastrointestinal bleeding while on therapy that was likely due to an indwelling feeding tube and this patient tolerated rapamycin well following tube removal. Our initial clinical experience supports that patients with peripheral pulmonary artery stenosis can be safely treated with rapamycin. Systemic rapamycin may provide a novel medical approach to reduce in-stent stenosis.
Joint multi-object registration and segmentation of left and right cardiac ventricles in 4D cine MRI
NASA Astrophysics Data System (ADS)
Ehrhardt, Jan; Kepp, Timo; Schmidt-Richberg, Alexander; Handels, Heinz
2014-03-01
The diagnosis of cardiac function based on cine MRI requires the segmentation of cardiac structures in the images, but the problem of automatic cardiac segmentation is still open, due to the imaging characteristics of cardiac MR images and the anatomical variability of the heart. In this paper, we present a variational framework for joint segmentation and registration of multiple structures of the heart. To enable the simultaneous segmentation and registration of multiple objects, a shape prior term is introduced into a region competition approach for multi-object level set segmentation. The proposed algorithm is applied for simultaneous segmentation of the myocardium as well as the left and right ventricular blood pool in short axis cine MRI images. Two experiments are performed: first, intra-patient 4D segmentation with a given initial segmentation for one time-point in a 4D sequence, and second, a multi-atlas segmentation strategy is applied to unseen patient data. Evaluation of segmentation accuracy is done by overlap coefficients and surface distances. An evaluation based on clinical 4D cine MRI images of 25 patients shows the benefit of the combined approach compared to sole registration and sole segmentation.
Beer, Meinrad; Weidemann, Frank; Breunig, Frank; Knoll, Anita; Koeppe, Sabrina; Machann, Wolfram; Hahn, Dietbert; Wanner, Christoph; Strotmann, Jörg; Sandstede, Jörn
2006-05-15
The present study evaluated the evolution of cardiac morphology, function, and late enhancement as a noninvasive marker of myocardial fibrosis, and their inter-relation during enzyme replacement therapy in patients with Fabry's disease using magnetic resonance imaging and color Doppler myocardial imaging. Late enhancement, which was present in up to 50% of patients, was associated with increased left ventricular mass, the failure of a significant regression of hypertrophy during enzyme replacement therapy, and worse segmental myocardial function. Late enhancement may predict the effect of enzyme replacement therapy on left ventricular mass and cardiac function.
De Bondt, Pieter; Nichols, Kenneth; Vandenberghe, Stijn; Segers, Patrick; De Winter, Olivier; Van de Wiele, Christophe; Verdonck, Pascal; Shazad, Arsalan; Shoyeb, Abu H; De Sutter, Johan
2003-06-01
We have developed a biventricular dynamic physical cardiac phantom to test gated blood-pool (GBP) SPECT image-processing algorithms. Such phantoms provide absolute values against which to assess accuracy of both right and left computed ventricular volume and ejection fraction (EF) measurements. Two silicon-rubber chambers driven by 2 piston pumps simulated crescent-shaped right ventricles wrapped partway around ellopsoid left ventricles. Twenty experiments were performed at Ghent University, for which right and left ventricular true volume and EF ranges were 65-275 mL and 55-165 mL and 7%-49% and 12%-69%, respectively. Resulting 64 x 64 simulated GBP SPECT images acquired at 16 frames per R-R interval were sent to Columbia University, where 2 observers analyzed images independently of each other, without knowledge of true values. Algorithms automatically segmented right ventricular activity volumetrically from left ventricular activity. Automated valve planes, midventricular planes, and segmentation regions were presented to observers, who accepted these choices or modified them as necessary. One observer repeated measurements >1 mo later without reference to previous determinations. Linear correlation coefficients (r) of the mean of the 3 GBP SPECT observations versus true values for right and left ventricles were 0.80 and 0.94 for EF and 0.94 and 0.95 for volumes, respectively. Correlations for right and left ventricles were 0.97 and 0.97 for EF and 0.96 and 0.89 for volumes, respectively, for interobserver agreement and 0.97 and 0.98 for EF and 0.96 and 0.90 for volumes, respectively, for intraobserver agreement. No trends were detected, though volumes and right ventricular EFs were significantly higher than true values. Overall, GBP SPECT measurements correlated strongly with true values. The phantom evaluated shows considerable promise for helping to guide algorithm developments for improved GBP SPECT accuracy.
Meng, Yanhong; Zong, Ling; Zhang, Ziteng; Han, Youdong; Wang, Yanhui
2018-02-01
We aimed to evaluate the changes in left ventricular structure and function in hypertensive patients with coronary artery disease before and after percutaneous coronary intervention (PCI) using real-time three-dimensional echocardiography. Two hundred and eighty hypertensive patients with coronary artery disease undergoing PCI and 120 cases who did not receive PCI in our hospital were selected as the subjects of our study. All patients were administered with routine antiplatelet, anticoagulant, lipid-lowering, antihypertensive, dilating coronary artery and other medications. The left ventricular systolic function and systolic synchrony index changes before and after subjects were treated by PCI were analyzed using three-dimensional echocardiography. At 2 days before surgery, there were no significant differences in the left ventricular end-diastolic volume, left ventricular end-systolic volume (LVESV) and ejection fraction (EF) between the two patient groups (P>0.05). At 3 months and 9 months, the two key time points after PCI, the LVESV level in the PCI group was distinctly decreased, while EF was significantly increased (P<0.05). In addition, before treatment, there were no significant differences in the parameters of time from the corresponding segment of the myocardium to the minimal systolic volume in two patient groups, such as Tmsv-16SD, Tmsv-16Dif, Tmsv-12SD, Tmsv-12Dif, Tmsv-6SD and Tmsv-6Dif (P>0.05); however, the parameters of time from the corresponding segment of the myocardium to the minimal systolic volume in patients in the PCI group were significantly reduced at 3 and 9 months after surgery (P<0.05). Three-dimensional echocardiography can evaluate the critical parameters in the prognosis of hypertensive patients with coronary artery disease after PCI accurately and in real-time, which may play a significant role.
Nunes, Maria Carmo P; Badano, Luigi Paolo; Marin-Neto, J Antonio; Edvardsen, Thor; Fernández-Golfín, Covadonga; Bucciarelli-Ducci, Chiara; Popescu, Bogdan A; Underwood, Richard; Habib, Gilbert; Zamorano, Jose Luis; Saraiva, Roberto Magalhães; Sabino, Ester Cerdeira; Botoni, Fernando A; Barbosa, Márcia Melo; Barros, Marcio Vinicius L; Falqueto, Eduardo; Simões, Marcus Vinicius; Schmidt, André; Rochitte, Carlos Eduardo; Rocha, Manoel Otávio Costa; Ribeiro, Antonio Luiz Pinho; Lancellotti, Patrizio
2018-04-01
To develop a document by Brazilian Cardiovascular Imaging Department (DIC) and the European Association of Cardiovascular Imaging (EACVI) to review and summarize the most recent evidences about the non-invasive assessment of patients with Chagas disease, with the intent to set up a framework for standardized cardiovascular imaging to assess cardiovascular morphologic and functional disturbances, as well as to guide the subsequent process of clinical decision-making. Chagas disease remains one of the most prevalent infectious diseases in Latin America, and has become a health problem in non-endemic countries. Dilated cardiomyopathy is the most severe manifestation of Chagas disease, which causes substantial disability and early mortality in the socially most productive population leading to a significant economical burden. Prompt and correct diagnosis of Chagas disease requires specialized clinical expertise to recognize the unique features of this disease. The appropriate and efficient use of cardiac imaging is pivotal for diagnosing the cardiac involvement in Chagas disease, to stage the disease, assess patients' prognosis and address management. Echocardiography is the most common imaging modality used to assess, and follow-up patients with Chagas disease. The presence of echocardiographic abnormalities is of utmost importance, since it allows to stage patients according to disease progression. In early stages of cardiac involvement, echocardiography may demonstrate segmental left ventricuar wall motion abnormalities, mainly in the basal segments of inferior, inferolateral walls, and the apex, which cannot be attributed to obstructive coronary artery arteries. The prevalence of segmental wall motion abnormalities varies according to the stage of the disease, reaching about 50% in patients with left ventricular dilatation and dysfunction. Speckle tracking echocardiography allows a more precise and quantitative measurement of the regional myocardial function. Since segmental wall motion abnormalities are frequent in Chagas disease, speckle tracking echocardiography may have an important clinical application in these patients, particularly in the indeterminate forms when abnormalities are more subtle. Speckle tracking echocardiography can also quantify the heterogeneity of systolic contraction, which is associated with the risk of arrhythmic events. Three-dimensional (3D) echocardiography is superior to conventional two-dimensional (2D) echocardiography for assessing more accurately the left ventricular apex and thus to detect apical aneurysms and thrombus in patients in whom ventricular foreshortening is suspected by 2D echocardiography. In addition, 3D echocardiography is more accurate than 2D Simpson s biplane rule for assessing left ventricular volumes and function in patients with significant wall motion abnormalities, including aneurysms with distorted ventricular geometry. Contrast echocardiography has the advantage to enhancement of left ventricular endocardial border, allowing for more accurate detection of ventricular aneurysms and thrombus in Chagas disease. Diastolic dysfunction is an important hallmark of Chagas disease even in its early phases. In general, left ventricular diastolic and systolic dysfunction coexist and isolated diastolic dysfunction is uncommon but may be present in patients with the indeterminate form. Right ventricular dysfunction may be detected early in the disease course, but in general, the clinical manifestations occur late at advanced stages of Chagas cardiomyopathy. Several echocardiographic parameters have been used to assess right ventricular function in Chagas disease, including qualitative evaluation, myocardial performance index, tissue Doppler imaging, tricuspid annular plane systolic excursion, and speckle tracking strain. Cardiac magnetic resonance (CMR) is useful to assess global and regional left ventricular function in patients with Chagas diseases. Myocardial fibrosis is a striking feature of Chagas cardiomyopathy and late gadolinium enhancement (LGE) is used to detect and quantify the extension of myocardial fibrosis. Myocardial fibrosis might have a role in risk stratification of patients with Chagas disease. Limited data are available regarding right ventricular function assessed by CMR in Chagas disease. Radionuclide ventriculography is used for global biventricular function assessment in patients with suspected or definite cardiac involvement in Chagas disease with suboptimal acoustic window and contraindication to CMR. Myocardial perfusion scintigraphy may improve risk stratification to define cardiac involvement in Chagas disease, especially in the patients with devices who cannot be submitted to CMR and in the clinical setting of Chagas patients whose main complaint is atypical chest pain. Detection of reversible ischemic defects predicts further deterioration of left ventricular systolic function and helps to avoid unnecessary cardiac catheterization and coronary angiography. Cardiac imaging is crucial to detect the cardiac involvement in patients with Chagas disease, stage the disease and stratify patient risk and address management. Unfortunately, most patients live in regions with limited access to imaging methods and point-of-care, simplified protocols, could improve the access of these remote populations to important information that could impact in the clinical management of the disease. Therefore, there are many fields for further research in cardiac imaging in Chagas disease. How to better provide an earlier diagnosis of cardiac involvement and improve patients risk stratification remains to be addressed using different images modalities.
Kannan, Arun; Das, Anindita; Janardhanan, Rajesh
2014-06-24
A 28-year-old man arrived for an outpatient cardiac MRI (CMR) study to evaluate cardiac structure. At the age of 24 the patient presented with acute onset expressive aphasia and was diagnosed with ischaemic stroke. Echocardiography at that time was reported as 'apical wall thickening consistent with apical hypertrophic cardiomyopathy'. CMR revealed a moderately dilated left ventricle with abnormal appearance of the left ventricular (LV) apical segments. Further evaluation was consistent with a diagnosis of LV non-compaction (LVNC) cardiomyopathy with a ratio of non-compacted to compacted myocardium measuring 3. There was extensive delayed hyperenhancement signal involving multiple segments representing a significant myocardial scar which is shown to have a prognostic role. Our patient, with no significant cerebrovascular risk factors, would likely have had an embolic stroke. This case demonstrates the role of CMR in accurately diagnosing LVNC in a patient with young stroke where prior echocardiography was non-diagnostic. 2014 BMJ Publishing Group Ltd.
Young patients with cystic fibrosis demonstrate subtle alterations of the cardiovascular system.
Eising, Jacobien B; van der Ent, Cornelis K; Teske, Arco J; Vanderschuren, Maaike M; Uiterwaal, Cuno S P M; Meijboom, Folkert J
2018-02-02
As life expectancy increases in patients with cystic fibrosis, it is important to pay attention to extra-pulmonary comorbidities. Several studies have shown signs of myocardial dysfunction in adult patients, but little is known about onset and development of these changes over time. In this prospective study, cardiac function in children with cystic fibrosis was compared to that of healthy children. 33 children, aged 3-12years, with cystic fibrosis were recruited from the Wilhelmina Children's hospital and 33 age-matched healthy children were selected from the WHISTLER study, a population-based cohort study. Measurements of lung function, arterial stiffness, and echocardiography (conventional measures and myocardial deformation imaging) were performed. There were no differences in anthropometrics, lung function and blood pressure between the two groups. The cystic fibrosis children had a higher arterial stiffness compared to the healthy children (pulse wave velocity respectively 5.76±0.57m/s versus 5.43±0.61m/s, p-value 0.049). Using conventional echocardiographic parameters for right ventricular function, Tricuspid Annular Plane Systolic Excursion) and Tissue Doppler Imaging, cystic fibrosis children had a reduced right ventricular systolic function when compared to the healthy children. After adjustment for lung function, global strains of both right and left ventricles were significantly lower in the cystic fibrosis group than in healthy children (linear regression coefficient 1.45% left ventricle, p-value 0.022 and 4.42% right ventricle, p-value <0.01). Systolic strain rate of basal segment of the left ventricle, the mid segment of the right ventricle and the apical septum were significantly lower in the cystic fibrosis children than in healthy controls. Our study suggests that already at a very young age, children with cystic fibrosis show an increased arterial stiffness and some signs of diminished both right and left ventricular function. Copyright © 2018. Published by Elsevier B.V.
Maffessanti, Francesco; Prinzen, Frits W; Conte, Giulio; Regoli, François; Caputo, Maria Luce; Suerder, Daniel; Moccetti, Tiziano; Faletra, Francesco; Krause, Rolf; Auricchio, Angelo
2018-01-01
This study sought to test the accuracy of strain measurements based on anatomo-electromechanical mapping (AEMM) measurements compared with magnetic resonance imaging (MRI) tagging, to evaluate the diagnostic value of AEMM-based strain measurements in the assessment of myocardial viability, and the additional value of AEMM over peak-to-peak local voltages. The in vivo identification of viable tissue, evaluation of mechanical contraction, and simultaneous left ventricular activation is currently achieved using multiple complementary techniques. In 33 patients, AEMM maps (NOGA XP, Biologic Delivery Systems, Division of Biosense Webster, a Johnson & Johnson Company, Irwindale, California) and MRI images (Siemens 3T, Siemens Healthcare, Erlangen, Germany) were obtained within 1 month. MRI tagging was used to determine circumferential strain (E cc ) and delayed enhancement to obtain local scar extent (%). Custom software was used to measure E cc and local area strain (LAS) from the motion field of the AEMM catheter tip. Intertechnique agreement for E cc was good (R 2 = 0.80), with nonsignificant bias (0.01 strain units) and narrow limits of agreement (-0.03 to 0.06). Scar segments showed lower absolute strain amplitudes compared with nonscar segments: E cc (median [first to third quartile]: nonscar -0.10 [-0.15 to -0.06] vs. scar -0.04 [-0.06 to -0.02]) and LAS (-0.20 [-0.27 to -0.14] vs. -0.09 [-0.14 to -0.06]). AEMM strains accurately discriminated between scar and nonscar segments, in particular LAS (area under the curve: 0.84, accuracy = 0.76), which was superior to peak-to-peak voltages (nonscar 9.5 [6.5 to 13.3] mV vs. scar 5.6 [3.4 to 8.3] mV; area under the curve: 0.75). Combination of LAS and peak-to-peak voltages resulted in 86% accuracy. An integrated AEMM approach can accurately determine local deformation and correlates with the scar extent. This approach has potential immediate application in the diagnosis, delivery of intracardiac therapies, and their intraprocedural evaluation. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Milne, Marjorie E; Steward, Christopher; Firestone, Simon M; Long, Sam N; O'Brien, Terrence J; Moffat, Bradford A
2016-04-01
To develop representative MRI atlases of the canine brain and to evaluate 3 methods of atlas-based segmentation (ABS). 62 dogs without clinical signs of epilepsy and without MRI evidence of structural brain disease. The MRI scans from 44 dogs were used to develop 4 templates on the basis of brain shape (brachycephalic, mesaticephalic, dolichocephalic, and combined mesaticephalic and dolichocephalic). Atlas labels were generated by segmenting the brain, ventricular system, hippocampal formation, and caudate nuclei. The MRI scans from the remaining 18 dogs were used to evaluate 3 methods of ABS (manual brain extraction and application of a brain shape-specific template [A], automatic brain extraction and application of a brain shape-specific template [B], and manual brain extraction and application of a combined template [C]). The performance of each ABS method was compared by calculation of the Dice and Jaccard coefficients, with manual segmentation used as the gold standard. Method A had the highest mean Jaccard coefficient and was the most accurate ABS method assessed. Measures of overlap for ABS methods that used manual brain extraction (A and C) ranged from 0.75 to 0.95 and compared favorably with repeated measures of overlap for manual extraction, which ranged from 0.88 to 0.97. Atlas-based segmentation was an accurate and repeatable method for segmentation of canine brain structures. It could be performed more rapidly than manual segmentation, which should allow the application of computer-assisted volumetry to large data sets and clinical cases and facilitate neuroimaging research and disease diagnosis.
An unsupervised approach for measuring myocardial perfusion in MR image sequences
NASA Astrophysics Data System (ADS)
Discher, Antoine; Rougon, Nicolas; Preteux, Francoise
2005-08-01
Quantitatively assessing myocardial perfusion is a key issue for the diagnosis, therapeutic planning and patient follow-up of cardio-vascular diseases. To this end, perfusion MRI (p-MRI) has emerged as a valuable clinical investigation tool thanks to its ability of dynamically imaging the first pass of a contrast bolus in the framework of stress/rest exams. However, reliable techniques for automatically computing regional first pass curves from 2D short-axis cardiac p-MRI sequences remain to be elaborated. We address this problem and develop an unsupervised four-step approach comprising: (i) a coarse spatio-temporal segmentation step, allowing to automatically detect a region of interest for the heart over the whole sequence, and to select a reference frame with maximal myocardium contrast; (ii) a model-based variational segmentation step of the reference frame, yielding a bi-ventricular partition of the heart into left ventricle, right ventricle and myocardium components; (iii) a respiratory/cardiac motion artifacts compensation step using a novel region-driven intensity-based non rigid registration technique, allowing to elastically propagate the reference bi-ventricular segmentation over the whole sequence; (iv) a measurement step, delivering first-pass curves over each region of a segmental model of the myocardium. The performance of this approach is assessed over a database of 15 normal and pathological subjects, and compared with perfusion measurements delivered by a MRI manufacturer software package based on manual delineations by a medical expert.
Long-term results after left ventricular aneurysmectomy.
Otterstad, J E; Christensen, O; Levorstad, K; Nitter-Hauge, S
1981-01-01
Twenty-six patients (21 men and five women) with a mean age of 54.8 years have been reinvestigated nine to 62 months (mean 29.7) after left ventricular aneurysmectomy. Preoperatively left ventricular angiography disclosed an anterior aneurysm in all cases, which was large in 15 (57%) and small to medium in 11 (42%). At follow-up a large residual aneurysm was found in five (19%), a small to medium one in 13 (50%), and akinesia without aneurysm in eight (31%). The sum of ST elevation (sigma ST) in praecordial leads in the electrocardiogram was reduced from a mean value of 11.2 mm to 7.7 mm. In no patient did ST segments return to normal after operation. Preoperatively, mean sigma ST was identical in patients with large and with small to medium aneurysms. At reinvestigation mean sigma ST was identical in patients with large and with small to medium residual aneurysms as well as in patients with akinesia. Left ventricular end-diastolic pressure before angiography was reduced from a mean value of 21.5 mm to 15.1 mmHg and after angiography from 26.7 mm to 21.1 mmHg. Progression of coronary artery stenoses was a characteristic finding in patients whose left ventricular end-diastolic pressures did not return to normal. These patients had a longer follow-up time than those with no progression of coronary disease, who all showed an improvement in left ventricular end-diastolic pressure. Six patients who had coronary bypass grafting performed had unchanged left ventricular end-diastolic pressures at follow-up. The results indicate that progression of coronary artery disease may be responsible for an eventual further deterioration in left ventricular function after aneurysmectomy. Additional bypass grafting did not result in improved left ventricular function. PMID:6971647
[A case of coronary artery spasm during epidural anesthesia with continuous infusion of propofol].
Inoue, Hisashi; Ogawa, Katsumi; Takano, Yoshito; Sato, Isao; Okuda, Yasuhisa
2003-07-01
A 50-year-old male patient was scheduled for left partial pulmonary resection and biopsy. The patient had neither complication nor history of ischemic heart disease. After arriving in the operation room, an epidural catheter was inserted into the epidural space at the T 4-5 intervertebral space. Anesthesia was induced with intravenous propofol 100 mg, fentanyl 100 microgram and vecuronium 6 mg and then a double lumen endotracheal tube was inserted. Anesthesia was maintained with O2 and air (FIO2 0.3-1.0), continuous infusion of propofol, intermittent intravenous administration of fentanyl and epidural injection of 1% lidocaine. Forty-five minutes after the start of operation, ECG showed an elevation of ST segment and soon it passed into ventricular tachycardia and ventricular fibrillation. The patient was treated with cardiopulmonary resuscitation. Fifteen minutes later, ECG returned to sinus rhythm but the elevation of ST segment remained. We considered that these cardiac events were due to coronary spasm, and started continuous infusion of nitroglycerin and nicorandil. One hour later, ST segment returned to normal. The possible inducing factors in this case were altered balance between sympathetic and parasympathetic nervous activity caused by infusion of propofol and epidural block, and alpha-stimulation caused by ephedrine.
Dambrauskaite, Virginija; Delcroix, Marion; Claus, Piet; Herbots, Lieven; Palecek, Tomas; D'hooge, Jan; Bijnens, Bart; Rademakers, Frank; Sutherland, George R
2005-11-01
Right ventricular (RV) blood pool-derived isovolumic relaxation time (IVRT) correlates well with systolic pulmonary arterial pressure (PAP). However, because of complex parameter derivation, the method is rarely used. The aim of this study was to validate the measurement of myocardial velocity imaging-derived RV IVRT (IVRT') against invasively measured PAP. Transthoracic echocardiography with myocardial velocity imaging and right heart catheterization were performed in 33 patients with pulmonary hypertension. Blood pool IVRT and myocardial IVRTs for the tricuspid valve annulus ring, basal and apical RV free wall segments were measured and compared with data from 33 age- and sex-matched control subjects. Measured IVRTs were significantly longer in patients with pulmonary hypertension than in control subjects. The strongest correlation (R = 0.74, P < .0001) was found between systolic PAP and the heart rate-corrected IVRT' derived from the basal RV free wall segment. The basal segment IVRT' corrected for heart rate correlates well with the invasive PAP measurement and, therefore, can be used to predict systolic PAP. It can even be considered as an alternative to tricuspid regurgitation-derived PAP systolic when tricuspid regurgitation is nonrecordable. A proposed method to derive systolic PAP should be used while screening the patients at risk for pulmonary hypertension, monitoring the disease progression and the effect of treatment.
Angina pectoris in a child with sickle cell anemia.
Hamilton, W; Rosenthal, A; Berwick, D; Nadas, A S
1978-06-01
A 7-year-old black boy with sickle cell disease, Wolff-Parkinson-White syndrome, mild left ventricular dysfunction, and normal coronary arteries developed angina pectoris five months after cessation of hypertransfusion therapy. Exercise-induced ECG ST segment depression associated with angina disappeared following transfusion therapy.
Silva, Etelvino; Bijnens, Bart; Berruezo, Antonio; Mont, Lluis; Doltra, Adelina; Andreu, David; Brugada, Josep; Sitges, Marta
2014-10-01
There is extensive controversy exists on whether cardiac resynchronization therapy corrects electrical or mechanical asynchrony. The aim of this study was to determine if there is a correlation between electrical and mechanical sequences and if myocardial scar has any relevant impact. Six patients with normal left ventricular function and 12 patients with left ventricular dysfunction and left bundle branch block, treated with cardiac resynchronization therapy, were studied. Real-time three-dimensional echocardiography and electroanatomical mapping were performed in all patients and, where applicable, before and after therapy. Magnetic resonance was performed for evaluation of myocardial scar. Images were postprocessed and mechanical and electrical activation sequences were defined and time differences between the first and last ventricular segment to be activated were determined. Response to therapy was defined as a reduction in left ventricular end-systolic volume ≥ 15% after 12 months of follow-up. Good correlation between electrical and mechanical timings was found in patients with normal left ventricular function (r(2) = 0.88; P = .005) but not in those with left ventricular dysfunction (r(2) = 0.02; P = not significant). After therapy, both timings and sequences were modified and improved, except in those with myocardial scar. Despite a close electromechanical relationship in normal left ventricular function, there is no significant correlation in patients with dysfunction. Although resynchronization therapy improves this correlation, the changes in electrical activation may not yield similar changes in left ventricular mechanics particularly depending on the underlying myocardial substrate. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Takotsubo cardiomyopathy associated with Miller-Fisher syndrome.
Gill, Dalvir; Liu, Kan
2017-07-01
51-year-old female who presented with progressive paresthesia, numbness of the lower extremities, double vision, and trouble walking. Physical exam was remarkable for areflexia, and ptosis. Her initial EKG showed nonspecific ST segment changes and her Troponin T was elevated to 0.41ng/mL which peaked at 0.66ng/mL. Echocardiogram showed a depressed left ventricular ejection fraction to 35% with severely hypokinetic anterior wall and left ventricular apex was severely hypokinetic. EMG nerve conduction study showed severely decreased conduction velocity and prolonged distal latency in all nerves consistent with demyelinating disease. She was treated with 5days of intravenous immunoglobulin therapy to which she showed significant improvement in strength in her lower extremities. Echocardiogram repeated 4days later showing an improved left ventricular ejection fraction of 55% and no left ventricular wall motion abnormalities. Takotsubo cardiomyopathy is a rare complication of Miller-Fisher syndrome and literature review did not reveal any cases. Miller-Fisher syndrome is an autoimmune process that affects the peripheral nervous system causing autonomic dysfunction which may involve the heart. Due to significant autonomic dysfunction in Miller-Fisher syndrome, it could lead to arrhythmias, blood pressure changes, acute coronary syndrome and myocarditis, Takotsubo cardiomyopathy can be difficult to distinguish. The treatment of Takotsubo cardiomyopathy is supportive with beta-blockers and angiotensin-converting enzyme inhibitors are recommended until left ventricle ejection fraction improvement. Takotsubo cardiomyopathy is a rare complication during the acute phase of Miller-Fisher syndrome and must be distinguished from autonomic dysfunction as both diagnoses have different approaches to treatment. Published by Elsevier Inc.
Szél, Tamás; Koncz, István; Antzelevitch, Charles
2013-11-01
Brugada syndrome is an inherited disease associated with vulnerability to ventricular tachycardia and sudden cardiac death in young adults. Milrinone and cilostazol, oral phosphodiesterase (PDE) type III inhibitors, have been shown to increase L-type calcium channel current (ICa) and modestly increase heart rate by elevating the level of intracellular cyclic adenosine monophosphate. To examine the effectiveness of these PDE inhibitors to suppress arrhythmogenesis in an experimental model of Brugada syndrome. Action potential (AP) and electrocardiographic recordings were obtained from epicardial and endocardial sites of coronary-perfused canine right ventricular wedge preparations. The Ito agonist NS5806 (5 μM) and Ca(2+) channel blocker verapamil (2 μM) were used to pharmacologically mimic Brugada phenotype. The combination induced all-or-none repolarization at some epicardial sites but not others, leading to ST-segment elevation as well as an increase in both epicardial and transmural dispersion of repolarization. Under these conditions, phase 2 reentry developed as the epicardial AP dome propagated from sites where it was maintained to sites at which it was lost, generating closely coupled extrasystoles and ventricular tachycardia. The addition of the PDE inhibitor milrinone (2.5 μM) or cilostazol (5-10 μM) to the coronary perfusate restored the epicardial AP dome, reduced dispersion, and abolished phase 2 reentry-induced extrasystoles and ventricular tachycardia. Our study identifies milrinone as a more potent alternative to cilostazol for reversing the repolarization defects responsible for the electrocardiographic and arrhythmic manifestations of Brugada syndrome. Both drugs normalize ST-segment elevation and suppress arrhythmogenesis in experimental models of Brugada syndrome. © 2013 Heart Rhythm Society. All rights reserved.
Carberry, Jaclyn; Carrick, David; Haig, Caroline; Rauhalammi, Samuli M; Ahmed, Nadeem; Mordi, Ify; McEntegart, Margaret; Petrie, Mark C; Eteiba, Hany; Hood, Stuart; Watkins, Stuart; Lindsay, Mitchell; Davie, Andrew; Mahrous, Ahmed; Ford, Ian; Sattar, Naveed; Welsh, Paul; Radjenovic, Aleksandra; Oldroyd, Keith G; Berry, Colin
2016-08-01
The natural history and pathophysiological significance of tissue remodeling in the myocardial remote zone after acute ST-elevation myocardial infarction (STEMI) is incompletely understood. Extracellular volume (ECV) in myocardial regions of interest can now be measured with cardiac magnetic resonance imaging. Patients who sustained an acute STEMI were enrolled in a cohort study (BHF MR-MI [British Heart Foundation Magnetic Resonance Imaging in Acute ST-Segment Elevation Myocardial Infarction study]). Cardiac magnetic resonance was performed at 1.5 Tesla at 2 days and 6 months post STEMI. T1 modified Look-Locker inversion recovery mapping was performed before and 15 minutes after contrast (0.15 mmol/kg gadoterate meglumine) in 140 patients at 2 days post STEMI (mean age: 59 years, 76% male) and in 131 patients at 6 months post STEMI. Remote zone ECV was lower than infarct zone ECV (25.6±2.8% versus 51.4±8.9%; P<0.001). In multivariable regression, left ventricular ejection fraction was inversely associated with remote zone ECV (P<0.001), and diabetes mellitus was positively associated with remote zone ECV (P=0.010). No ST-segment resolution (P=0.034) and extent of ischemic area at risk (P<0.001) were multivariable associates of the change in remote zone ECV at 6 months (ΔECV). ΔECV was a multivariable associate of the change in left ventricular end-diastolic volume at 6 months (regression coefficient [95% confidence interval]: 1.43 (0.10-2.76); P=0.036). ΔECV is implicated in the pathophysiology of left ventricular remodeling post STEMI, but because the effect size is small, ΔECV has limited use as a clinical biomarker of remodeling. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02072850. © 2016 The Authors.
Carberry, Jaclyn; Carrick, David; Haig, Caroline; Rauhalammi, Samuli M.; Ahmed, Nadeem; Mordi, Ify; McEntegart, Margaret; Petrie, Mark C.; Eteiba, Hany; Hood, Stuart; Watkins, Stuart; Lindsay, Mitchell; Davie, Andrew; Mahrous, Ahmed; Ford, Ian; Sattar, Naveed; Welsh, Paul; Radjenovic, Aleksandra; Oldroyd, Keith G.
2016-01-01
The natural history and pathophysiological significance of tissue remodeling in the myocardial remote zone after acute ST-elevation myocardial infarction (STEMI) is incompletely understood. Extracellular volume (ECV) in myocardial regions of interest can now be measured with cardiac magnetic resonance imaging. Patients who sustained an acute STEMI were enrolled in a cohort study (BHF MR-MI [British Heart Foundation Magnetic Resonance Imaging in Acute ST-Segment Elevation Myocardial Infarction study]). Cardiac magnetic resonance was performed at 1.5 Tesla at 2 days and 6 months post STEMI. T1 modified Look-Locker inversion recovery mapping was performed before and 15 minutes after contrast (0.15 mmol/kg gadoterate meglumine) in 140 patients at 2 days post STEMI (mean age: 59 years, 76% male) and in 131 patients at 6 months post STEMI. Remote zone ECV was lower than infarct zone ECV (25.6±2.8% versus 51.4±8.9%; P<0.001). In multivariable regression, left ventricular ejection fraction was inversely associated with remote zone ECV (P<0.001), and diabetes mellitus was positively associated with remote zone ECV (P=0.010). No ST-segment resolution (P=0.034) and extent of ischemic area at risk (P<0.001) were multivariable associates of the change in remote zone ECV at 6 months (ΔECV). ΔECV was a multivariable associate of the change in left ventricular end-diastolic volume at 6 months (regression coefficient [95% confidence interval]: 1.43 (0.10–2.76); P=0.036). ΔECV is implicated in the pathophysiology of left ventricular remodeling post STEMI, but because the effect size is small, ΔECV has limited use as a clinical biomarker of remodeling. Clinical Trial Registration— URL: https://www.clinicaltrials.gov. Unique identifier: NCT02072850. PMID:27354423
Nanjyo, S
1994-09-01
In order to evaluate left ventricular regional wall motion and regional myocardial perfusion, 99mTc-HSAD multigated cardiac blood pool emission computed tomography (cardiac pool SPECT) and 201Tl myocardial SPECT (Tl) were performed on 12 patients with acute myocardial infarction (AMI), 6 patients had treated with only thrombolysis in group I and 6 patients had treated with thrombolysis and selective PTCA in group II, 17 patients with old myocardial infarction (OMI) in group III and 5 normal volunteers (controls). The relationship between left ventricular regional wall motion and regional myocardial perfusion was estimated. The relationship between % length shortening (%LS) by cardiac pool SPECT and %Tl uptake (%TU) was good (r = 0.820) in group III. The value for %TU in the segments of akinesia was low (35%) and in the those of severe hypokinesia was higher (48%). In all phases, two groups showed significant relationships between %LS and %TU in group I and II. The %TU was unchanged in the akinetic segment, the %LS changed 30% in group I and the %LS changed to 49% in group II. If the %TU is more than 50% (AMI) or 40% (OMI), we would observe viable muscle. The combination of Tl and cardiac pool SPECT are useful for evaluating myocardial viability in the patients with AMI.
Regional growth and atlasing of the developing human brain
Makropoulos, Antonios; Aljabar, Paul; Wright, Robert; Hüning, Britta; Merchant, Nazakat; Arichi, Tomoki; Tusor, Nora; Hajnal, Joseph V.; Edwards, A. David; Counsell, Serena J.; Rueckert, Daniel
2016-01-01
Detailed morphometric analysis of the neonatal brain is required to characterise brain development and define neuroimaging biomarkers related to impaired brain growth. Accurate automatic segmentation of neonatal brain MRI is a prerequisite to analyse large datasets. We have previously presented an accurate and robust automatic segmentation technique for parcellating the neonatal brain into multiple cortical and subcortical regions. In this study, we further extend our segmentation method to detect cortical sulci and provide a detailed delineation of the cortical ribbon. These detailed segmentations are used to build a 4-dimensional spatio-temporal structural atlas of the brain for 82 cortical and subcortical structures throughout this developmental period. We employ the algorithm to segment an extensive database of 420 MR images of the developing brain, from 27 to 45 weeks post-menstrual age at imaging. Regional volumetric and cortical surface measurements are derived and used to investigate brain growth and development during this critical period and to assess the impact of immaturity at birth. Whole brain volume, the absolute volume of all structures studied, cortical curvature and cortical surface area increased with increasing age at scan. Relative volumes of cortical grey matter, cerebellum and cerebrospinal fluid increased with age at scan, while relative volumes of white matter, ventricles, brainstem and basal ganglia and thalami decreased. Preterm infants at term had smaller whole brain volumes, reduced regional white matter and cortical and subcortical grey matter volumes, and reduced cortical surface area compared with term born controls, while ventricular volume was greater in the preterm group. Increasing prematurity at birth was associated with a reduction in total and regional white matter, cortical and subcortical grey matter volume, an increase in ventricular volume, and reduced cortical surface area. PMID:26499811
Regional growth and atlasing of the developing human brain.
Makropoulos, Antonios; Aljabar, Paul; Wright, Robert; Hüning, Britta; Merchant, Nazakat; Arichi, Tomoki; Tusor, Nora; Hajnal, Joseph V; Edwards, A David; Counsell, Serena J; Rueckert, Daniel
2016-01-15
Detailed morphometric analysis of the neonatal brain is required to characterise brain development and define neuroimaging biomarkers related to impaired brain growth. Accurate automatic segmentation of neonatal brain MRI is a prerequisite to analyse large datasets. We have previously presented an accurate and robust automatic segmentation technique for parcellating the neonatal brain into multiple cortical and subcortical regions. In this study, we further extend our segmentation method to detect cortical sulci and provide a detailed delineation of the cortical ribbon. These detailed segmentations are used to build a 4-dimensional spatio-temporal structural atlas of the brain for 82 cortical and subcortical structures throughout this developmental period. We employ the algorithm to segment an extensive database of 420 MR images of the developing brain, from 27 to 45weeks post-menstrual age at imaging. Regional volumetric and cortical surface measurements are derived and used to investigate brain growth and development during this critical period and to assess the impact of immaturity at birth. Whole brain volume, the absolute volume of all structures studied, cortical curvature and cortical surface area increased with increasing age at scan. Relative volumes of cortical grey matter, cerebellum and cerebrospinal fluid increased with age at scan, while relative volumes of white matter, ventricles, brainstem and basal ganglia and thalami decreased. Preterm infants at term had smaller whole brain volumes, reduced regional white matter and cortical and subcortical grey matter volumes, and reduced cortical surface area compared with term born controls, while ventricular volume was greater in the preterm group. Increasing prematurity at birth was associated with a reduction in total and regional white matter, cortical and subcortical grey matter volume, an increase in ventricular volume, and reduced cortical surface area. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Bybee, Kevin A; Motiei, Arashk; Syed, Imran S; Kara, Tomas; Prasad, Abhiram; Lennon, Ryan J; Murphy, Joseph G; Hammill, Stephen C; Rihal, Charanjit S; Wright, R Scott
2007-01-01
The presentation and electrocardiographic (ECG) characteristics of transient left ventricular apical ballooning syndrome (TLVABS) can be similar to that of anterior ST-segment elevation myocardial infarction (STEMI). We tested the hypothesis that the ECG on presentation could reliably differentiate these syndromes. Between January 1, 2002 and July 31, 2004, we identified 18 consecutive patients with TLVABS who were matched with 36 subjects presenting with acute anterior STEMI due to atherothrombotic left anterior descending coronary artery occlusion. All patients with TLVABS were women (mean age, 72.0 +/- 13.1 years). The heart rate, PR interval, QRS duration, and corrected QT interval were similar between groups. Distribution of ST elevation was similar, but patients with anterior STEMI exhibited greater ST elevation. Regressive partitioning analysis indicated that the combination of ST elevation in lead V2 of less than 1.75 mm and ST-segment elevation in lead V3 of less than 2.5 mm was a suggestive predictor of TLVABS (sensitivity, 67%; specificity, 94%). Conditional logistic regression indicated that the formula: (3 x ST-elevation lead V2) + (ST-elevation V3) + (2 x ST-elevation V5) allowed possible discrimination between TLVABS and anterior STEMI with an optimal cutoff level of less than 11.5 mm for TLVABS (sensitivity, 94%; specificity, 72%). Patients with TLVABS were less likely to have concurrent ST-segment depression (6% vs 44%; P = .003). Women presenting with TLVABS have similar ECG findings to patients with anterior infarct but with less-prominent ST-segment elevation in the anterior precordial ECG leads. These ECG findings are relatively subtle and do not have sufficient predictive value to allow reliable emergency differentiation of these syndromes.
NASA Astrophysics Data System (ADS)
Morais, Pedro; Queirós, Sandro; Heyde, Brecht; Engvall, Jan; 'hooge, Jan D.; Vilaça, João L.
2017-09-01
Cardiovascular diseases are among the leading causes of death and frequently result in local myocardial dysfunction. Among the numerous imaging modalities available to detect these dysfunctional regions, cardiac deformation imaging through tagged magnetic resonance imaging (t-MRI) has been an attractive approach. Nevertheless, fully automatic analysis of these data sets is still challenging. In this work, we present a fully automatic framework to estimate left ventricular myocardial deformation from t-MRI. This strategy performs automatic myocardial segmentation based on B-spline explicit active surfaces, which are initialized using an annular model. A non-rigid image-registration technique is then used to assess myocardial deformation. Three experiments were set up to validate the proposed framework using a clinical database of 75 patients. First, automatic segmentation accuracy was evaluated by comparing against manual delineations at one specific cardiac phase. The proposed solution showed an average perpendicular distance error of 2.35 ± 1.21 mm and 2.27 ± 1.02 mm for the endo- and epicardium, respectively. Second, starting from either manual or automatic segmentation, myocardial tracking was performed and the resulting strain curves were compared. It is shown that the automatic segmentation adds negligible differences during the strain-estimation stage, corroborating its accuracy. Finally, segmental strain was compared with scar tissue extent determined by delay-enhanced MRI. The results proved that both strain components were able to distinguish between normal and infarct regions. Overall, the proposed framework was shown to be accurate, robust, and attractive for clinical practice, as it overcomes several limitations of a manual analysis.
NASA Astrophysics Data System (ADS)
Dangi, Shusil; Linte, Cristian A.
2017-03-01
Segmentation of right ventricle from cardiac MRI images can be used to build pre-operative anatomical heart models to precisely identify regions of interest during minimally invasive therapy. Furthermore, many functional parameters of right heart such as right ventricular volume, ejection fraction, myocardial mass and thickness can also be assessed from the segmented images. To obtain an accurate and computationally efficient segmentation of right ventricle from cardiac cine MRI, we propose a segmentation algorithm formulated as an energy minimization problem in a graph. Shape prior obtained by propagating label from an average atlas using affine registration is incorporated into the graph framework to overcome problems in ill-defined image regions. The optimal segmentation corresponding to the labeling with minimum energy configuration of the graph is obtained via graph-cuts and is iteratively refined to produce the final right ventricle blood pool segmentation. We quantitatively compare the segmentation results obtained from our algorithm to the provided gold-standard expert manual segmentation for 16 cine-MRI datasets available through the MICCAI 2012 Cardiac MR Right Ventricle Segmentation Challenge according to several similarity metrics, including Dice coefficient, Jaccard coefficient, Hausdorff distance, and Mean absolute distance error.
MRI as a tool to study brain structure from mouse models for mental retardation
NASA Astrophysics Data System (ADS)
Verhoye, Marleen; Sijbers, Jan; Kooy, R. F.; Reyniers, E.; Fransen, E.; Oostra, B. A.; Willems, Peter; Van der Linden, Anne-Marie
1998-07-01
Nowadays, transgenic mice are a common tool to study brain abnormalities in neurological disorders. These studies usually rely on neuropathological examinations, which have a number of drawbacks, including the risk of artefacts introduced by fixation and dehydration procedures. Here we present 3D Fast Spin Echo Magnetic Resonance Imaging (MRI) in combination with 2D and 3D segmentation techniques as a powerful tool to study brain anatomy. We set up MRI of the brain in mouse models for the fragile X syndrome (FMR1 knockout) and Corpus callosum hypoplasia, mental Retardation, Adducted thumbs, Spastic paraplegia and Hydrocephalus (CRASH) syndrome (L1CAM knockout). Our major goal was to determine qualitative and quantitative differences in specific brain structures. MRI of the brain of fragile X and CRASH patients has revealed alterations in the size of specific brain structures, including the cerebellar vermis and the ventricular system. In the present MRI study of the brain from fragile X knockout mice, we have measured the size of the brain, cerebellum and 4th ventricle, which were reported as abnormal in human fragile X patients, but found no evidence for altered brain regions in the mouse model. In CRASH syndrome, the most specific brain abnormalities are vermis hypoplasia and abnormalities of the ventricular system with some degree of hydrocephalus. With the MRI study of L1CAM knockout mice we found vermis hypoplasia, abnormalities of the ventricular system including dilatation of the lateral and the 4th ventricles. These subtle abnormalities were not detected upon standard neuropathological examination. Here we proved that this sensitive MRI technique allows to measure small differences which can not always be detected by means of pathology.
Rischpler, Christoph; Dirschinger, Ralf J; Nekolla, Stephan G; Kossmann, Hans; Nicolosi, Stefania; Hanus, Franziska; van Marwick, Sandra; Kunze, Karl P; Meinicke, Alexander; Götze, Katharina; Kastrati, Adnan; Langwieser, Nicolas; Ibrahim, Tareq; Nahrendorf, Matthias; Schwaiger, Markus; Laugwitz, Karl-Ludwig
2016-04-01
The immune system orchestrates the repair of infarcted myocardium. Imaging of the cellular inflammatory response by (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography/magnetic resonance imaging in the heart has been demonstrated in preclinical and clinical studies. However, the clinical relevance of post-MI (18)F-FDG uptake in the heart has not been elucidated. The objective of this study was to explore the value of (18)F-FDG positron emission tomography/magnetic resonance imaging in patients after acute myocardial infarction as a biosignal for left ventricular functional outcome. We prospectively enrolled 49 patients with ST-segment-elevation myocardial infarction and performed (18)F-FDG positron emission tomography/magnetic resonance imaging 5 days after percutaneous coronary intervention and follow-up cardiac magnetic resonance imaging after 6 to 9 months. In a subset of patients, (99m)Tc-sestamibi single-photon emission computed tomography was performed with tracer injection before revascularization. Cellular innate immune response was analyzed at multiple time points. Segmental comparison of (18)F-FDG-uptake and late gadolinium enhancement showed substantial overlap (κ=0.66), whereas quantitative analysis demonstrated that (18)F-FDG extent exceeded late gadolinium enhancement extent (33.2±16.2% left ventricular myocardium versus 20.4±10.6% left ventricular myocardium, P<0.0001) and corresponded to the area at risk (r=0.87, P<0.0001). The peripheral blood count of CD14(high)/CD16(+) monocytes correlated with the infarction size and (18)F-FDG signal extent (r=0.53, P<0.002 and r=0.42, P<0.02, respectively). (18)F-FDG uptake in the infarcted myocardium was highest in areas with transmural scar, and the standardized uptake valuemean was associated with left ventricular functional outcome independent of infarct size (Δ ejection fraction: P<0.04, Δ end-diastolic volume: P<0.02, Δ end-systolic volume: P<0.005). In this study, the intensity of (18)F-FDG uptake in the myocardium after acute myocardial infarction correlated inversely with functional outcome at 6 months. Thus, (18)F-FDG uptake in infarcted myocardium may represent a novel biosignal of myocardial injury. © 2016 American Heart Association, Inc.
Kukla, Piotr; Kosior, Dariusz A; Tomaszewski, Andrzej; Ptaszyńska-Kopczyńska, Katarzyna; Widejko, Katarzyna; Długopolski, Robert; Skrzyński, Andrzej; Błaszczak, Piotr; Fijorek, Kamil; Kurzyna, Marcin
2017-07-01
Electrocardiography (ECG) is still one of the first tests performed at admission, mostly in patients (pts) with chest pain or dyspnea. The aim of this study was to assess the correlation between electrocardiographic abnormalities and cardiac biomarkers as well as echocardiographic parameter in patients with acute pulmonary embolism. We performed a retrospective analysis of 614 pts. (F/M 334/280; mean age of 67.9 ± 16.6 years) with confirmed acute pulmonary embolism (APE) who were enrolled to the ZATPOL-2 Registry between 2012 and 2014. Elevated cardiac biomarkers were observed in 358 pts (74.4%). In this group the presence of atrial fibrillation (p = .008), right axis deviation (p = .004), S 1 Q 3 T 3 sign (p < .001), RBBB (p = .006), ST segment depression in leads V 4 -V 6 (p < .001), ST segment depression in lead I (p = .01), negative T waves in leads V 1 -V 3 (p < .001), negative T waves in leads V 4 -V 6 (p = .005), negative T waves in leads II, III and aVF (p = .005), ST segment elevation in lead aVR (p = .002), ST segment elevation in lead III (p = .0038) was significantly more frequent in comparison to subjects with normal serum level of cardiac biomarkers. In multivariate regression analysis, clinical predictors of "abnormal electrocardiogram" were as follows: increased heart rate (OR 1.09, 95% CI 1.02-1.17, p = .012), elevated troponin concentration (OR 3.33, 95% CI 1.94-5.72, p = .000), and right ventricular overload (OR 2.30, 95% CI 1.17-4.53, p = .016). Electrocardiographic signs of right ventricular strain are strongly related to elevated cardiac biomarkers and echocardiographic signs of right ventricular overload. ECG may be used in preliminary risk stratification of patient with intermediate- or high-risk forms of APE. © 2017 Wiley Periodicals, Inc.
Cerebral atrophy in elderly with subjective memory complaints.
Palm, Walter M; Ferrarini, Luca; van der Flier, Wiesje M; Westendorp, Rudi G J; Bollen, Eduard L E M; Middelkoop, Huub A M; Milles, Julien R; van der Grond, Jeroen; van Buchem, Mark A
2013-08-01
To evaluate ventricular shape differences along the complete surface of the lateral and third ventricles of persons with subjective memory complaints (MC). We included 28 controls and 21 persons with MC. FLAIR, T2, and PD-weighted brain MRI scans were acquired at 1.5 Tesla, followed by semi-automated segmentation of the lateral and third ventricles, and local shape difference analysis based on growing and adaptive meshes. Ventricular meshes were used to highlight local areas with significant differences between controls and persons with MC, determined by permutation tests with a predefined threshold (P = 0.01). Compared with control subjects, relevant differences were found in the shape of the ventricular surface adjacent to the thalamus and corona radiata in persons with MC. Before correction for multiple comparisons, relevant differences were also found in the shape of the ventricular surface adjacent to the corpus callosum, hippocampus, and amydala. Our findings suggest the presence of localized structural brain differences in patients with subjective memory complaints in the thalamus and the corona radiata. Copyright © 2013 Wiley Periodicals, Inc.
Pellerin, D; Sharma, R; Elliott, P; Veyrat, C
2003-01-01
Tissue Doppler (TDE), strain, and strain rate echocardiography are emerging real time ultrasound techniques that provide a measure of wall motion. They offer an objective means to quantify global and regional left and right ventricular function and to improve the accuracy and reproducibility of conventional echocardiography studies. Radial and longitudinal ventricular function can be assessed by the analysis of myocardial wall velocity and displacement indices, or by the analysis of wall deformation using the rate of deformation of a myocardial segment (strain rate) and its deformation over time (strain). A quick and easy assessment of left ventricular ejection fraction is obtained by mitral annular velocity measurement during a routine study, especially in patients with poor endocardial definition or abnormal septal motion. Strain rate and strain are less affected by passive myocardial motion and tend to be uniform throughout the left ventricle in normal subjects. This paper reviews the underlying principles of TDE, strain, and strain rate echocardiography and discusses currently available quantification tools and clinical applications. PMID:14594870
Tako-tsubo-like syndrome, a case report.
Patanè, Salvatore; Marte, Filippo
2008-02-29
Tako-tsubo-like (Japanese word for octopus-catcher) left ventricular dysfunction is an enigmatic cardiomyopathy. Typically, the patients have a history of recent stressful incidents immediately preceding onset of mild to moderate chest pain, have ST-segment elevation in leads V3 through V6, ECG changes that typically demonstrate diffuse T-wave inversions and abnormal QS-wave development, discrete wall motion abnormalities involving the lower anterior wall and apex on echocardiography or left ventriculography, and limited myocardial enzyme release without evidence for hemodynamically significant coronary arterial stenoses by angiography. We describe a case of a Tako-tsubo-like left ventricular dysfunction in a 72-year-old female Italian woman.
Left Ventricular Assist Devices: The Adolescence of a Disruptive Technology.
Pinney, Sean P
2015-10-01
Clinical outcomes for patients with advanced heart failure receiving left ventricular assist devices are driven by appropriate patient selection, refined surgical technique, and coordinated medical care. Perhaps even more important is innovative pump design. The introduction and widespread adoption of continuous-flow ventricular assist devices has led to a paradigm shift within the field of mechanical circulatory support, making the promise of lifetime device therapy closer to reality. The disruption caused by this new technology, on the one hand, produced meaningful improvements in patient survival and quality of life, but also introduced new clinical challenges, such as bleeding, pump thrombosis, and acquired valvular heart disease. Further evolution within this field will require financial investment to sustain innovation leading to a fully implantable, durable, and cost-effective pump for a larger segment of patients with advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.
Cardot, J C; Berthout, P; Verdenet, J; Bidet, A; Faivre, R; Bassand, J P; Bidet, R; Maurat, J P
1982-01-01
Regional and global left ventricular wall motion was assessed in 120 patients using radionuclide cineangiography (RCA) and contrast angiography. Functional imaging procedures based on a temporal Fourier analysis of dynamic image sequences were applied to the study of cardiac contractility. Two images were constructed by taking the phase and amplitude values of the first harmonic in the Fourier transform for each pixel. These two images aided in determining the perimeter of the left ventricle to calculate the global ejection fraction. Regional left ventricular wall motion was studied by analyzing the phase value and by examining the distribution histogram of these values. The accuracy of global ejection fraction calculation was improved by the Fourier technique. This technique increased the sensitivity of RCA for determining segmental abnormalities especially in the left anterior oblique view (LAO).
Urbano-Moral, Jose Angel; Gangadharamurthy, Dakshin; Comenzo, Raymond L; Pandian, Natesa G; Patel, Ayan R
2015-08-01
The study of myocardial mechanics has a potential role in the detection of cardiac involvement in patients with amyloidosis. This study aimed to characterize 3-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics in light chain amyloidosis and examine their relationship with brain natriuretic peptide. In patients with light chain amyloidosis, left ventricular longitudinal and circumferential strain (n=40), and right ventricular longitudinal strain and radial displacement (n=26) were obtained by 3-dimensional-speckle tracking echocardiography. Brain natriuretic peptide levels were determined. All myocardial mechanics measurements showed differences when compared by brain natriuretic peptide level tertiles. Left and right ventricular longitudinal strain were highly correlated (r=0.95, P<.001). Left ventricular longitudinal and circumferential strain were reduced in patients with cardiac involvement (-9±4 vs -16±2; P<.001, and -24±6 vs -29±4; P=.01, respectively), with the most prominent impairment at the basal segments. Right ventricular longitudinal strain and radial displacement were diminished in patients with cardiac involvement (-9±3 vs -17±3; P<.001, and 2.7±0.8 vs 3.8±0.3; P=.002). On multivariate analysis, left ventricular longitudinal strain was associated with the presence of cardiac involvement (odds ratio = 1.6; 95% confidence interval, 1.04 to 2.37; P=.03) independent of the presence of brain natriuretic peptide and troponin I criteria for cardiac amyloidosis. Three-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics are increasingly altered as brain natriuretic peptide increases in light chain amyloidosis. There appears to be a strong association between left ventricular longitudinal strain and cardiac involvement, beyond biomarkers such as brain natriuretic peptide and troponin I. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Porras, Antonio R; Piella, Gemma; Berruezo, Antonio; Hoogendoorn, Corne; Andreu, David; Fernandez-Armenta, Juan; Sitges, Marta; Frangi, Alejandro F
2013-05-01
Scar presence and its characteristics play a fundamental role in several cardiac pathologies. To accurately define the extent and location of the scar is essential for a successful ventricular tachycardia ablation procedure. Nowadays, a set of widely accepted electrical voltage thresholds applied to local electrograms recorded are used intraoperatively to locate the scar. Information about cardiac mechanics could be considered to characterize tissues with different viability properties. We propose a novel method to estimate endocardial motion from data obtained with an electroanatomical mapping system together with the endocardial geometry segmented from preoperative 3-D magnetic resonance images, using a statistical atlas constructed with bilinear models. The method was validated using synthetic data generated from ultrasound images of nine volunteers and was then applied to seven ventricular tachycardia patients. Maximum bipolar voltages, commonly used to intraoperatively locate scar tissue, were compared to endocardial wall displacement and strain for all the patients. The results show that the proposed method allows endocardial motion and strain estimation and that areas with low-voltage electrograms also present low strain values.
Yu, Zeyun; Holst, Michael J.; Hayashi, Takeharu; Bajaj, Chandrajit L.; Ellisman, Mark H.; McCammon, J. Andrew; Hoshijima, Masahiko
2009-01-01
A general framework of image-based geometric processing is presented to bridge the gap between three-dimensional (3D) imaging that provides structural details of a biological system and mathematical simulation where high-quality surface or volumetric meshes are required. A 3D density map is processed in the order of image pre-processing (contrast enhancement and anisotropic filtering), feature extraction (boundary segmentation and skeletonization), and high-quality and realistic surface (triangular) and volumetric (tetrahedral) mesh generation. While the tool-chain described is applicable to general types of 3D imaging data, the performance is demonstrated specifically on membrane-bound organelles in ventricular myocytes that are imaged and reconstructed with electron microscopic (EM) tomography and two-photon microscopy (T-PM). Of particular interest in this study are two types of membrane-bound Ca2+-handling organelles, namely, transverse tubules (T-tubules) and junctional sarcoplasmic reticulum (jSR), both of which play an important role in regulating the excitation-contraction (E-C) coupling through dynamic Ca2+ mobilization in cardiomyocytes. PMID:18835449
Yu, Zeyun; Holst, Michael J; Hayashi, Takeharu; Bajaj, Chandrajit L; Ellisman, Mark H; McCammon, J Andrew; Hoshijima, Masahiko
2008-12-01
A general framework of image-based geometric processing is presented to bridge the gap between three-dimensional (3D) imaging that provides structural details of a biological system and mathematical simulation where high-quality surface or volumetric meshes are required. A 3D density map is processed in the order of image pre-processing (contrast enhancement and anisotropic filtering), feature extraction (boundary segmentation and skeletonization), and high-quality and realistic surface (triangular) and volumetric (tetrahedral) mesh generation. While the tool-chain described is applicable to general types of 3D imaging data, the performance is demonstrated specifically on membrane-bound organelles in ventricular myocytes that are imaged and reconstructed with electron microscopic (EM) tomography and two-photon microscopy (T-PM). Of particular interest in this study are two types of membrane-bound Ca(2+)-handling organelles, namely, transverse tubules (T-tubules) and junctional sarcoplasmic reticulum (jSR), both of which play an important role in regulating the excitation-contraction (E-C) coupling through dynamic Ca(2+) mobilization in cardiomyocytes.
Alteration of Left Ventricular Function with Dobutamine Challenge in Patients with Myocardial Bridge
Jhi, Joon-Hyung; Ha, Jong-kun; Jung, Chan-Woo; kim, Bong-Jae; Park, Seong-Oh; Jo, A-Ra; Kim, Seong-Man; Lee, Hyeon-Gook; Kim, Tae-Ik
2011-01-01
Background/Aims The aim of this study was to identify changes in left ventricular (LV) performance in patients with a myocardial bridge (MB) in the left anterior descending coronary artery during resting and in an inotropic state. Methods Myocardial strain measurement by speckle-tracking echocardiography and conventional LV wall-motion scoring was performed in 18 patients with MB (mean age, 48.1 ± 1.7 years, eight female) during resting and intravenous dobutamine challenge (10 and 20 µg/kg/min). Results Conventional LV wall-motion scoring was normal in all patients during resting and in an inotropic state. Peak regional circumferential strain increased dose dependently upon dobutamine challenge. Longitudinal strains of the anterior and anteroseptal segments were, however, reduced at 20 µg/kg/min and showed a dyssynchronous pattern at 20 µg/kg/min. Although there were no significant differences in radial strain and displacement of all segments at rest compared with under 10 µg/kg/min challenge, radial strain and displacement of anterior segments at 20 µg/kg/min were significantly reduced compared with posterior segments at the papillary muscle level (44.8 ± 14.9% vs. 78.4 ± 20.1% and 5.3 ± 2.3 mm vs. 8.5 ± 1.8 mm, respectively; all p < 0.001), and showed plateau (40%) or biphasic (62%) patterns. Conclusions Reduced LV strain of patients with MB after inotropic stimulation was identified. Speckle-tracking strain echocardiography identified a LV myocardial dyssynchrony that was not demonstrated by conventional echocardiography in patients with MB. PMID:22205841
Barkauskas, Kestutis J; Rajiah, Prabhakar; Ashwath, Ravi; Hamilton, Jesse I; Chen, Yong; Ma, Dan; Wright, Katherine L; Gulani, Vikas; Griswold, Mark A; Seiberlich, Nicole
2014-09-11
The standard clinical acquisition for left ventricular functional parameter analysis with cardiovascular magnetic resonance (CMR) uses a multi-breathhold multi-slice segmented balanced SSFP sequence. Performing multiple long breathholds in quick succession for ventricular coverage in the short-axis orientation can lead to fatigue and is challenging in patients with severe cardiac or respiratory disorders. This study combines the encoding efficiency of a six-fold undersampled 3D stack of spirals balanced SSFP sequence with 3D through-time spiral GRAPPA parallel imaging reconstruction. This 3D spiral method requires only one breathhold to collect the dynamic data. Ten healthy volunteers were recruited for imaging at 3 T. The 3D spiral technique was compared against 2D imaging in terms of systolic left ventricular functional parameter values (Bland-Altman plots), total scan time (Welch's t-test) and qualitative image rating scores (Wilcoxon signed-rank test). Systolic left ventricular functional values were not significantly different (i.e. 3D-2D) between the methods. The 95% confidence interval for ejection fraction was -0.1 ± 1.6% (mean ± 1.96*SD). The total scan time for the 3D spiral technique was 48 s, which included one breathhold with an average duration of 14 s for the dynamic scan, plus 34 s to collect the calibration data under free-breathing conditions. The 2D method required an average of 5 min 40s for the same coverage of the left ventricle. The difference between 3D and 2D image rating scores was significantly different from zero (Wilcoxon signed-rank test, p < 0.05); however, the scores were at least 3 (i.e. average) or higher for 3D spiral imaging. The 3D through-time spiral GRAPPA method demonstrated equivalent systolic left ventricular functional parameter values, required significantly less total scan time and yielded acceptable image quality with respect to the 2D segmented multi-breathhold standard in this study. Moreover, the 3D spiral technique used just one breathhold for dynamic imaging, which is anticipated to reduce patient fatigue as part of the complete cardiac examination in future studies that include patients.
Hypo-Fractionated Conformal Radiation Therapy to the Tumor Bed After Segmental Mastectomy
2004-07-01
conserving surgery for breast cancer were first offered slan- speed helical CT scanner . CT images were transferred to dard conventional 6-week RT. Only...Zhou S, Prosnitz RG, et al. The impact of breast cancer treated with breast conserving therapy. J Surg im, diated left ventricular volume on the
Li, Yinbo; Garson, Christopher D.; Xu, Yaqin; Helm, Patrick A.; Hossack, John A.; French, Brent A.
2011-01-01
This study noninvasively evaluated the development of left ventricular (LV) dyssynchrony following reperfused myocardial infarction (MI) in mice using an ultrasonic speckle-tracking method. Eight C57BL/6J mice were assessed by high-resolution echocardiography at baseline and at eight time-points following MI. Images were acquired at 1mm elevational intervals encompassing the entire LV to determine chamber volumes and radial strain. Receiver-operating characteristic (ROC) analysis of regional radial strain was used to segment the three-dimensional (3-D) LV into infarct, adjacent and remote zones. This in vivo segmentation was correlated to histologic infarct size (R = 0.89, p < 0.01) in a short-axis, slice-by-slice comparison. The onset of dyssynchrony during LV remodeling was assessed by standard deviation of time to peak radial strain in the infarct, adjacent and remote zones. It was discovered that the form of LV dyssynchrony that develops in the remote zone late after MI does so in concert with the progression of LV remodeling (R = 0.70, p < 0.05). PMID:21640480
Bosch, Xavier; Théroux, Pierre
2005-08-01
Improvement in risk stratification of patients with non-ST-segment elevation acute coronary syndrome (ACS) is a gateway to a more judicious treatment. This study examines whether the routine determination of left ventricular ejection fraction (EF) adds significant prognostic information to currently recommended stratifiers. Several predictors of inhospital mortality were prospectively characterized in a registry study of 1104 consecutive patients, for whom an EF was determined, who were admitted for an ACS. Multiple regression models were constructed using currently recommended clinical, electrocardiographic, and blood marker stratifiers, and values of EF were incorporated into the models. Age, ST-segment shifts, elevation of cardiac markers, and the Thrombolysis in Myocardial Infarction (TIMI) risk score all predicted mortality (P < .0001). Adding EF into the model improved the prediction of mortality (C statistic 0.73 vs 0.67). The odds of death increased by a factor of 1.042 for each 1% decrement in EF. By receiver operating curves, an EF cutoff of 48% provided the best predictive value. Mortality rates were 3.3 times higher within each TIMI risk score stratum in patients with an EF of 48% or lower as compared with those with higher. The TIMI risk score predicts inhospital mortality in a broad population of patients with ACS. The further consideration of EF adds significant prognostic information.
Saccheri, María Cristina; Cianciulli, Tomás Francisco; Morita, Luis Alberto; Méndez, Ricardo José; Beck, Martín Alejandro; Guerra, Juan Enrique; Cozzarin, Alberto; Puente, Luciana Jimena; Balletti, Lorena Romina; Lax, Jorge Alberto
2017-04-26
To explore regional systolic strain of midwall and endocardial segments using speckle tracking echocardiography in patients with apical hypertrophic cardiomyopathy (HCM). We prospectively assessed 20 patients (mean age 53 ± 16 years, range: 18-81 years, 10 were male), with apical HCM. We measured global longitudinal peak systolic strain (GLPSS) in the midwall and endocardium of the left ventricle. The diastolic thickness of the 4 apical segments was 16.25 ± 2.75 mm. All patients had a normal global systolic function with a fractional shortening of 50% ± 8%. In spite of supernormal left ventricular (LV) systolic function, midwall GLPSS was decreased in all patients, more in the apical (-7.3% ± -8.8%) than in basal segments (-15.5% ± -6.93%), while endocardial GLPPS was significantly greater and reached normal values (apical: -22.8% ± -7.8%, basal: -17.9% ± -7.5%). This study shows that two-dimensional strain was decreased mainly confined to the mesocardium, while endocardium myocardial deformation was preserved in HCM and allowed to identify subclinical LV dysfunction. This transmural heterogeneity in systolic strain had not been previously described in HCM and could be explained by the distribution of myofibrillar disarray in deep myocardial areas. The clinical application of this novel finding may help further understanding of the pathophysiology of HCM.
Acute catecholamine cardiomyopathy in patients with phaeochromocytoma or functional paraganglioma.
Giavarini, Alessandra; Chedid, Antoine; Bobrie, Guillaume; Plouin, Pierre-François; Hagège, Albert; Amar, Laurence
2013-10-01
Phaeochromocytomas and paragangliomas (PPGL) can cause acute catecholamine cardiomyopathy (ACC). We assessed the prevalence of ACC and compared the presentation of cases with and without ACC in a large series of PPGL. Single centre retrospective study. Hypertension Unit, University Hospital, Paris. 140 consecutive patients with PPGL, referred from January 2003 to September 2012. Left ventricular ejection fraction (LVEF), perioperative mortality. Fifteen patients (11%) had suffered an ACC, occurring in 14 cases before the diagnosis of PPGL. Precipitating factors were identified in 11 cases. Twelve patients presented with acute pulmonary oedema, including 10 with cardiogenic shock, requiring life support in eight cases. Seven patients (five with pulmonary oedema) presented with acute chest pain and cardiac dysfunction. Electrocardiographic abnormalities were present in 14 cases: ST segment elevation or pathological Q waves, ST segment depression, and/or diffuse T wave inversion. Six patients displayed classical (apical ballooning) or inverted (basal/mid ventricular stunning) takotsubo-like cardiomyopathy. Coronary arteries were always normal on angiography. In patients with ACC, median LVEF rose from 30% (IQR 23-33%) during ACC to 71% (50-72%) before surgery (n=11, p<0.001). Median LVEF before PPGL surgery was 65% (51-72%) and 65% (60-70%) in patients with and without a history of ACC, respectively (not significant). PPGL may present as ACC in 11% of cases, excluding patients dying from undiagnosed tumours. Left ventricular dysfunction is usually reversible before surgery. PPGL should be suspected in patients with acute heart failure without evidence of valvular or coronary artery disease.
Clinical significance of J-wave in elite athletes.
Pelliccia, Antonio; Quattrini, Filippo M
2015-01-01
The J-wave pattern on 12-lead ECG is traditionally defined as a positive deflection at junction between the end of the QRS and the beginning of the ST-segment. This pattern has recently been associated with increased risk for idiopathic ventricular fibrillation in the absence of cardiovascular disease. The interest for the clinical significance of J-wave pattern as a potential ECG hallmark of high risk for cardiac arrest has recently been reinforced by the growing practice of ECG screening, such as occurs in large population of young competitive athletes. The available scientific evidence shows that the J-wave pattern is relatively common in trained athletes (ranging from 14% to 44%) and, differently from subjects who suffered from ventricular fibrillation, commonly localized in lateral leads while it is relatively rare to be found in inferior leads. Furthermore the J-wave pattern has been demonstrated to be a dynamic phenomenon related to the training status, with the larger prominence at the peak of training and with an inverse relation between magnitude of J-wave and heart rate. In addition the J-wave pattern is usually associated with other ECG changes, such as increased QRS voltages and ST-segment elevation, as well as LV remodeling, suggesting that it likely represents another expression of the physiologic athlete's heart. Finally the scientific data available demonstrated that during a medium follow-up period the J-wave pattern does not convey risk for adverse cardiac events, including sudden death or ventricular tachyarrhythmias. Copyright © 2015 Elsevier Inc. All rights reserved.
De Boeck, Bart W L; Teske, Arco J; Leenders, Geert E; Mohamed Hoesein, Firdaus A A; Loh, Peter; van Driel, Vincent J; Doevendans, Pieter A; Prinzen, Frits W; Cramer, Maarten J
2010-08-15
Pacing experiments in healthy animal hearts have suggested a larger detrimental effect of septal compared to free wall preexcitation. We investigated the intrinsic relation among the site of electrical preexcitation, mechanical dyssynchrony, and dysfunction in human patients. In 33 patients with Wolff-Parkinson-White (WPW) syndrome and 18 controls, regional myocardial deformation was assessed by speckle tracking mapping (ST-Map) to assess the preexcitation site, shortening sequences and dyssynchrony, and the extent of local and global ejecting shortening. The ST-Map data in patients with accessory atrioventricular pathways correctly diagnosed as located in the interventricular septum (IVS) (n = 11) or left ventricular free wall (LFW) (n = 12) were compared to the corresponding control values. A local ejecting shortening of <2 SD of the control values identified hypokinetic segments. The localization of the atrioventricular pathways by ST-Map matched with the invasive electrophysiology findings in 23 of 33 patients and was one segment different in 5 of 33 patients. In both WPW-IVS and WPW-LFW, local ejecting shortening was impaired at the preexcitation site (p <0.01). However, at similar electrical and mechanical dyssynchrony, WPW-IVS had more extensive hypokinesia than did WPW-LFW (3.6 +/- 0.9 vs 1.8 +/- 1.3 segments, p <0.01). Compared to controls, the left ventricular function was significantly reduced only in WPW-IVS (global ejecting shortening 17 +/- 2% vs 19 +/- 2%, p = 0.01; ejection fraction 55 +/- 5% vs 59 +/- 3%, p = 0.02). In conclusion, preexcitation is associated with local hypokinesia, which at comparable preexcitation is more extensive in WPW-IVS than in WPW-LFW and could adversely affect ventricular function. ST-Map might have a future role in detecting and guiding treatment of septal pathways with significant mechanical effects.
Thrombus formation in the interrupted segment of the aorta.
Karavelioğlu, Yusuf; Kalçık, Macit; Yetim, Mucahit; Doğan, Tolga; Gölbaşı, Zehra
2017-06-01
Interrupted aorta is a very rare heart defect in which there is a gap between the ascending and the descending thoracic aorta. It is usually associated with other cardiac anomalies, including ventricular septal defect, ductus arteriosus, and truncus arteriosus. Severe cases present with serious complications such as hypertension, heart failure, or intracranial hemorrhage. Neurological complications are very rare form of presentation and commonly associated with intracranial aneurysms. We have reported a case of interrupted aorta who presented with transient ischemic attack due to thrombus formation in the interrupted segment of the aorta. © 2017, Wiley Periodicals, Inc.
Gomes, Victor Augusto M; Alves, Gabriel F; Hadlich, Marcelo; Azevedo, Clerio F; Pereira, Iane M; Santos, Carla Renata F; Brasil, Pedro Emmanuel A A; Sangenis, Luiz Henrique C; Cunha, Ademir B; Xavier, Sergio S; Saraiva, Roberto M
2016-07-01
Chagas heart disease has a high socioeconomic burden, and any strategy to detect early myocardial damage is welcome. Speckle-tracking echocardiography assesses global and segmental left ventricular (LV) systolic function, yielding values of two-dimensional strain (ε). The aim of this study was to determine if patients with chronic Chagas disease and normal LV ejection fractions present abnormalities in global and segmental LV ε. In this prospective study, patients with Chagas disease with no evidence of cardiac involvement (group I; n = 83) or at stage A of the cardiac form (i.e., with changes limited to the electrocardiogram) (group A; n = 42) and 43 control subjects (group C) underwent evaluation of global and segmental LV ε by speckle-tracking echocardiography. A subset of randomly selected patients in group A underwent cardiac magnetic resonance imaging and repeated echocardiography 3.5 ± 0.8 years after the first evaluation. Mean age, chamber dimensions, and LV ejection fraction were similar among the groups. Global longitudinal (group C, -19 ± 2%; group I, -19 ± 2%; group A, -19 ± 2%), circumferential (group C, -19 ± 3%; group I, -20 ± 3%; group A, -19 ± 3%), and radial (group C, 46 ± 10%; group I, 45 ± 13%; group A, 42 ± 14%) LV ε were similar among the groups. Segmental longitudinal, circumferential, and radial LV ε were similar across the studied groups. Seven of 14 patients had areas of fibrosis on cardiac magnetic resonance imaging. Patients with fibrosis had lower global longitudinal (-15 ± 2% vs -18 ± 2%, P = .004), circumferential (-14 ± 2% vs -19 ± 2%, P = .002), and radial LV ε (36 ± 13% vs 54 ± 12%, P = .02) than those without cardiac fibrosis despite similar LV ejection fractions. Patients with fibrosis had lower radial LV ε in the basal inferoseptal wall than patients without cardiac fibrosis (27 ± 17% vs 60 ± 15%, P = .04). Patients with chronic Chagas disease and normal global and segmental LV systolic function on two-dimensional echocardiography had global and segmental LV ε similar to that of control subjects. However, those in the early stages of the cardiac form and cardiac fibrosis had lower global longitudinal, circumferential, and radial LV ε. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Li, Bin; Yang, Hui; Wang, Xiaochen; Zhan, Yongkun; Sheng, Wei; Cai, Huanhuan; Xin, Haoyang; Liang, Qianqian; Zhou, Ping; Lu, Chao; Qian, Ruizhe; Chen, Sifeng; Yang, Pengyuan; Zhang, Jianyi; Shou, Weinian; Huang, Guoying; Liang, Ping; Sun, Ning
2017-09-29
Most infarctions occur in the left anterior descending coronary artery and cause myocardium damage of the left ventricle. Although current pluripotent stem cells (PSCs) and directed cardiac differentiation techniques are able to generate fetal-like human cardiomyocytes, isolation of pure ventricular cardiomyocytes has been challenging. For repairing ventricular damage, we aimed to establish a highly efficient purification system to obtain homogeneous ventricular cardiomyocytes and prepare engineered human ventricular heart muscles in a dish. The purification system used TALEN-mediated genomic editing techniques to insert the neomycin or EGFP selection marker directly after the myosin light chain 2 (MYL2) locus in human pluripotent stem cells. Purified early ventricular cardiomyocytes were estimated by immunofluorescence, fluorescence-activated cell sorting, quantitative PCR, microelectrode array, and patch clamp. In subsequent experiments, the mixture of mature MYL2-positive ventricular cardiomyocytes and mesenchymal cells were cocultured with decellularized natural heart matrix. Histological and electrophysiology analyses of the formed tissues were performed 2 weeks later. Human ventricular cardiomyocytes were efficiently isolated based on the purification system using G418 or flow cytometry selection. When combined with the decellularized natural heart matrix as the scaffold, functional human ventricular heart muscles were prepared in a dish. These engineered human ventricular muscles can be great tools for regenerative therapy of human ventricular damage as well as drug screening and ventricular-specific disease modeling in the future.
Changes in autonomic activity preceding onset of nonsustained ventricular tachycardia
NASA Technical Reports Server (NTRS)
Osaka, M.; Saitoh, H.; Sasabe, N.; Atarashi, H.; Katoh, T.; Hayakawa, H.; Cohen, R. J.
1996-01-01
Background: The triggering role of the autonomic nervous system in the initiation of ventricular tachycardia has not been established. To investigate the relationship between changes in autonomic activity and the occurrence of nonsustained ventricular tachycardia (NSVT) we examined heart rate variability (HRV) during the 2-hour period preceding spontaneous episodes of NSVT. Twenty-four subjects were identified retrospectively as having had one episode of NSVT during 24-hour Holter ECC recording. Methods: We measured the mean interval between normal heats (meanRR), the standard deviation of the intervals between beats (SD), the percentage of counts of sequential intervals between normal beats with a change of >50 ms (%RR50), the logarithms of low- and high-frequency spectral components (lnLF, lnHF) of HRV for sequential 10-minute segments preceding NSVT. The correlation dimension (CDim) of HRV was calculated similarly for sequential 20-minute segments. We assessed the significance of the time-course change of each marker over the 120-minute period prior to NSVT onset. Results: MeanRR (P < 0.05), lnLF (P < 0.0001), lnHF (P < 0.0001), the natural logarithm of the ratio of LF to HF (ln[LF/HF]; P < 0.05), and CDim (P < 0.05) showed significant time-course changes during that period, while SD and %RR50 did not. MeanRR, lnLF, lnHF, and CDim all decreased prior to the onset of NSVT, whereas ln(LF/HF) increased. We divided the subjects into two groups: one consisting of 12 patients with coronary artery disease; and the second group of 12 patients without known coronary artery disease. Both groups showed significant changes (P < 0.05) of CDim, lnLF, and lnHF preceding the episodes of NSVT. Conclusions: Changes in the pattern of HRV prior to the onset of episodes of NSVT suggest that changes in autonomic activity may commonly play a role in the triggering of spontaneous episodes of NSVT in susceptible patients. The measured changes suggest a reduction in parasympathetic activity, perhaps in conjunction with an increase in sympathetic activity, may trigger NSVT.
Capecitabine-induced ventricular fibrillation arrest: Possible Kounis syndrome.
Kido, Kazuhiko; Adams, Val R; Morehead, Richard S; Flannery, Alexander H
2016-04-01
We report the case of capecitabine-induced ventricular fibrillation arrest, possibly secondary to type I Kounis syndrome. A 47-year-old man with a history of T3N1 moderately differentiated adenocarcinoma of the colon, status-post sigmoid resection, was started on adjuvant capecitabine approximately five months prior to presentation of cardiac arrest secondary to ventricular fibrillation. An electrocardiogram (EKG) revealed ST segment elevation on the lateral leads and the patient was taken emergently to the cardiac catheterization laboratory. The catheterization revealed no angiographically significant stenosis and coronary artery disease was ruled out. After ruling out other causes of cardiac arrest, the working diagnosis was capecitabine-induced ventricular fibrillation arrest. As such, an inflammatory work up was sent to evaluate for the possibility of a capecitabine hypersensitivity, or Kounis syndrome, and is the first documented report in the literature to do so when evaluating Kounis syndrome. Immunoglobulin E (IgE), tryptase, and C-reactive protein were normal but histamine, interleukin (IL)-6, and IL-10 were elevated. Histamine elevation supports the suspicion that our patient had type I Kounis syndrome. Naranjo adverse drug reaction probability scale indicates a probable adverse effect due to capecitabine with seven points. A case of capecitabine-induced ventricular fibrillation arrest is reported, with a potential for type 1 Kounis syndrome as an underlying pathology supported by immunologic work up. © The Author(s) 2014.
Belle, Loic; Motreff, Pascal; Mangin, Lionel; Rangé, Grégoire; Marcaggi, Xavier; Marie, Antoine; Ferrier, Nadine; Dubreuil, Olivier; Zemour, Gilles; Souteyrand, Géraud; Caussin, Christophe; Amabile, Nicolas; Isaaz, Karl; Dauphin, Raphael; Koning, René; Robin, Christophe; Faurie, Benjamin; Bonello, Laurent; Champin, Stanislas; Delhaye, Cédric; Cuilleret, François; Mewton, Nathan; Genty, Céline; Viallon, Magalie; Bosson, Jean Luc; Croisille, Pierre
2016-03-01
Delayed stent implantation after restoration of normal epicardial flow by a minimalist immediate mechanical intervention aims to decrease the rate of distal embolization and impaired myocardial reperfusion after percutaneous coronary intervention. We sought to confirm whether a delayed stenting (DS) approach (24-48 hours) improves myocardial reperfusion, versus immediate stenting, in patients with acute ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention. In the prospective, randomized, open-label minimalist immediate mechanical intervention (MIMI) trial, patients (n=140) with ST-segment-elevation myocardial infarction ≤12 hours were randomized to immediate stenting (n=73) or DS (n=67) after Thrombolysis In Myocardial Infarction 3 flow restoration by thrombus aspiration. Patients in the DS group underwent a second coronary arteriography for stent implantation a median of 36 hours (interquartile range 29-46) after randomization. The primary end point was microvascular obstruction (% left ventricular mass) on cardiac magnetic resonance imaging performed 5 days (interquartile range 4-6) after the first procedure. There was a nonsignificant trend toward lower microvascular obstruction in the immediate stenting group compared with DS group (1.88% versus 3.96%; P=0.051), which became significant after adjustment for the area at risk (P=0.049). Median infarct weight, left ventricular ejection fraction, and infarct size did not differ between groups. No difference in 6-month outcomes was apparent for the rate of major cardiovascular and cerebral events. The present findings do not support a strategy of DS versus immediate stenting in patients with ST-segment-elevation infarction undergoing primary percutaneous coronary intervention and even suggested a deleterious effect of DS on microvascular obstruction size. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01360242. © 2016 American Heart Association, Inc.
Mirea, Oana; Pagourelias, Efstathios D; Duchenne, Jurgen; Bogaert, Jan; Thomas, James D; Badano, Luigi P; Voigt, Jens-Uwe
2018-01-01
In this study, we compared left ventricular (LV) segmental strain measurements obtained with different ultrasound machines and post-processing software packages. Global longitudinal strain (GLS) has proven to be a reproducible and valuable tool in clinical practice. Data about the reproducibility and intervendor differences of segmental strain measurements, however, are missing. We included 63 volunteers with cardiac magnetic resonance-proven infarct scar with segmental LV function ranging from normal to severely impaired. Each subject was examined within 2 h by a single expert sonographer with machines from multiple vendors. All 3 apical views were acquired twice to determine the test-retest and the intervendor variability. Segmental longitudinal peak systolic, end-systolic, and post-systolic strain were measured using 7 vendor-specific systems (Hitachi, Tokyo, Japan; Esaote, Florence, Italy; GE Vingmed Ultrasound, Horten, Norway; Philips, Andover, Massachusetts; Samsung, Seoul, South Korea; Siemens, Mountain View, California; and Toshiba, Otawara, Japan) and 2 independent software packages (Epsilon, Ann Arbor, Michigan; and TOMTEC, Unterschleissheim, Germany) and compared among vendors. Image quality and tracking feasibility differed among vendors (analysis of variance, p < 0.05). The absolute test-retest difference ranged from 2.5% to 4.9% for peak systolic, 2.6% to 5.0% for end-systolic, and 2.5% to 5.0% for post-systolic strain. The average segmental strain values varied significantly between vendors (up to 4.5%). Segmental strain parameters from each vendor correlated well with the mean of all vendors (r 2 range 0.58 to 0.81) but showed very different ranges of values. Bias and limits of agreement were up to -4.6 ± 7.5%. In contrast to GLS, LV segmental longitudinal strain measurements have a higher variability on top of the known intervendor bias. The fidelity of different software to follow segmental function varies considerably. We conclude that single segmental strain values should be used with caution in the clinic. Segmental strain pattern analysis might be a more robust alternative. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Mateos, Alonso; García-Lunar, Inés; García-Ruiz, José M; Pizarro, Gonzalo; Fernández-Jiménez, Rodrigo; Huertas, Pilar; García-Álvarez, Ana; Fernández-Friera, Leticia; Bravo, Jesús; Flores-Arias, José; Barreiro, María V; Chayán-Zas, Luisa; Corral, Ervigio; Fuster, Valentín; Sánchez-Brunete, Vicente; Ibáñez, Borja
2015-03-01
We seek to examine the efficacy and safety of prereperfusion emergency medical services (EMS)-administered intravenous metoprolol in anterior ST-segment elevation myocardial infarction patients undergoing eventual primary angioplasty. This is a prespecified subgroup analysis of the Effect of Metoprolol in Cardioprotection During an Acute Myocardial Infarction trial population, who all eventually received oral metoprolol within 12 to 24 hours. We studied patients receiving intravenous metoprolol by EMS and compared them with others treated by EMS but not receiving intravenous metoprolol. Outcomes included infarct size and left ventricular ejection fraction on cardiac magnetic resonance imaging at 1 week, and safety by measuring the incidence of the predefined combined endpoint (composite of death, malignant ventricular arrhythmias, advanced atrioventricular block, cardiogenic shock, or reinfarction) within the first 24 hours. From the total population of the trial (N=270), 147 patients (54%) were recruited during out-of-hospital assistance and transferred to the primary angioplasty center (74 intravenous metoprolol and 73 controls). Infarct size was smaller in patients receiving intravenous metoprolol compared with controls (23.4 [SD 15.0] versus 34.0 [SD 23.7] g; adjusted difference -11.4; 95% confidence interval [CI] -18.6 to -4.3). Left ventricular ejection fraction was higher in the intravenous metoprolol group (48.1% [SD 8.4%] versus 43.1% [SD 10.2%]; adjusted difference 5.0; 95% CI 1.6 to 8.4). Metoprolol administration did not increase the incidence of the prespecified safety combined endpoint: 6.8% versus 17.8% in controls (risk difference -11.1; 95% CI -21.5 to -0.6). Out-of-hospital administration of intravenous metoprolol by EMS within 4.5 hours of symptom onset in our subjects reduced infarct size and improved left ventricular ejection fraction with no excess of adverse events during the first 24 hours. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Link, M S; Wang, P J; VanderBrink, B A; Avelar, E; Pandian, N G; Maron, B J; Estes, N A
1999-07-27
Sudden death due to relatively innocent chest-wall impact has been described in young individuals (commotio cordis). In our previously reported swine model of commotio cordis, ventricular fibrillation (with T-wave strikes) and ST-segment elevation (with QRS strikes) were produced by 30-mph baseball impacts to the precordium. Because activation of the K(+)(ATP) channel has been implicated in the pathogenesis of ST elevation and ventricular fibrillation in myocardial ischemia, we hypothesized that this channel could be responsible for the electrophysiologic findings in our experimental model and in victims of commotio cordis. In the initial experiment, 6 juvenile swine were given 0.5 mg/kg IV glibenclamide, a selective inhibitor of the K(+)(ATP) channel, and chest impact was given on the QRS. The results of these strikes were compared with animals in which no glibenclamide was given. In the second phase, 20 swine were randomized to receive glibenclamide or a control vehicle (in a double-blind fashion), with chest impact delivered just before the T-wave peak. With QRS impacts, the maximal ST elevation was significantly less in those animals given glibenclamide (0.16+/-0.10 mV) than in controls (0.35+/-0.20 mV; P=0.004). With T-wave impacts, the animals that received glibenclamide had significantly fewer occurrences of ventricular fibrillation (1 episode in 27 impacts; 4%) than controls (6 episodes in 18 impacts; 33%; P=0.01). In this experimental model of commotio cordis, blockade of the K(+)(ATP) channel reduced the incidence of ventricular fibrillation and the magnitude of ST-segment elevation. Therefore, selective K(+)(ATP) channel activation may be a pivotal mechanism in sudden death resulting from low-energy chest-wall trauma in young people during sporting activities.
Cameli, Matteo; Lisi, Matteo; Righini, Francesca Maria; Tsioulpas, Charilaos; Bernazzali, Sonia; Maccherini, Massimo; Sani, Guido; Ballo, Piercarlo; Galderisi, Maurizio; Mondillo, Sergio
2012-03-01
Right ventricular (RV) systolic function has a critical role in determining the clinical outcome and success of using left ventricular assist devices (LVADs) in patients with refractory heart failure. Tissue Doppler and M-mode measurements of tricuspid systolic motion (tricuspid S' and tricuspid annular plane systolic excursion [TAPSE]) are the most currently used methods for the quantification of RV longitudinal function; RV deformation analysis by speckle-tracking echocardiography (STE) has recently allowed the analysis of global RV longitudinal function. Using cardiac catheterization as the reference standard, this study aimed at exploring the correlation between RV longitudinal function by STE and RV stroke work index (RVSWI) in patients referred for cardiac transplantation. Right-side heart catheterization and transthoracic echo Doppler were simultaneously performed in 41 patients referred for cardiac transplantation evaluation for advanced systolic heart failure. Thermodilution RV stroke volume and invasive pulmonary pressures were used to obtain RVSWI. RV longitudinal strain (RVLS) by STE was assessed averaging all segments in apical 4-chamber view (global RVLS) and by averaging RV free-wall segments (free-wall RVLS). Tricuspid S' and TAPSE were also calculated. No significant correlations were found for TAPSE or tricuspid S' with RVSWI (r = 0.14; r = 0.06; respectively). Close negative correlations between global RVLS and free-wall RVLS with the RVSWI were found (r = -0.75; r = -0.82; respectively; both P < .0001). Furthermore, free-wall RVLS demonstrated the highest diagnostic accuracy (area under the receiver operating characteristic (ROC) curve 0.90) and good sensitivity and specificity of 92% and 86%, respectively, to predict depressed RVSWI using a cutoff value of less than -11.8%. In a group of patients referred for heart transplantation, TAPSE and tricuspid S' did not correlate with invasively obtained RVSWI. RV longitudinal deformation analysis by STE correlated well with RVSWI, providing a better estimation of RV systolic performance. Copyright © 2012 Elsevier Inc. All rights reserved.
Planning of vessel grafts for reconstructive surgery in congenital heart diseases
NASA Astrophysics Data System (ADS)
Rietdorf, U.; Riesenkampff, E.; Schwarz, T.; Kuehne, T.; Meinzer, H.-P.; Wolf, I.
2010-02-01
The Fontan operation is a surgical treatment for patients with severe congenital heart diseases, where a biventricular correction of the heart can't be achieved. In these cases, a uni-ventricular system is established. During the last step of surgery a tunnel segment is placed to connect the inferior caval vein directly with the pulmonary artery, bypassing the right atrium and ventricle. Thus, the existing ventricle works for the body circulation, while the venous blood is passively directed to the pulmonary arteries. Fontan tunnels can be placed intra- and extracardially. The location, length and shape of the tunnel must be planned accurately. Furthermore, if the tunnel is placed extracardially, it must be positioned between other anatomical structures without constraining them. We developed a software system to support planning of the tunnel location, shape, and size, making pre-operative preparation of the tunnel material possible. The system allows for interactive placement and adjustment of the tunnel, affords a three-dimensional visualization of the virtual Fontan tunnel inside the thorax, and provides a quantification of the length, circumferences and diameters of the tunnel segments. The visualization and quantification can be used to plan and prepare the tunnel material for surgery in order to reduce the intra-operative time and to improve the fit of the tunnel patch.
Zhang, Zhijun; Zhu, Meihua; Ashraf, Muhammad; Broberg, Craig S; Sahn, David J; Song, Xubo
2014-12-01
Quantitative analysis of right ventricle (RV) motion is important for study of the mechanism of congenital and acquired diseases. Unlike left ventricle (LV), motion estimation of RV is more difficult because of its complex shape and thin myocardium. Although attempts of finite element models on MR images and speckle tracking on echocardiography have shown promising results on RV strain analysis, these methods can be improved since the temporal smoothness of the motion is not considered. The authors have proposed a temporally diffeomorphic motion estimation method in which a spatiotemporal transformation is estimated by optimization of a registration energy functional of the velocity field in their earlier work. The proposed motion estimation method is a fully automatic process for general image sequences. The authors apply the method by combining with a semiautomatic myocardium segmentation method to the RV strain analysis of three-dimensional (3D) echocardiographic sequences of five open-chest pigs under different steady states. The authors compare the peak two-point strains derived by their method with those estimated from the sonomicrometry, the results show that they have high correlation. The motion of the right ventricular free wall is studied by using segmental strains. The baseline sequence results show that the segmental strains in their methods are consistent with results obtained by other image modalities such as MRI. The image sequences of pacing steady states show that segments with the largest strain variation coincide with the pacing sites. The high correlation of the peak two-point strains of their method and sonomicrometry under different steady states demonstrates that their RV motion estimation has high accuracy. The closeness of the segmental strain of their method to those from MRI shows the feasibility of their method in the study of RV function by using 3D echocardiography. The strain analysis of the pacing steady states shows the potential utility of their method in study on RV diseases.
Gupta, Aakriti; Barrabes, Jose A; Strait, Kelly; Bueno, Hector; Porta-Sánchez, Andreu; Acosta-Vélez, J Gabriel; Lidón, Rosa-Maria; Spatz, Erica; Geda, Mary; Dreyer, Rachel P; Lorenze, Nancy; Lichtman, Judith; D'Onofrio, Gail; Krumholz, Harlan M
2018-03-07
Young women with ST-segment-elevation myocardial infarction experience reperfusion delays more frequently than men. Our aim was to determine the electrocardiographic correlates of delay in reperfusion in young patients with ST-segment-elevation myocardial infarction. We examined sex differences in initial electrocardiographic characteristics among 1359 patients with ST-segment-elevation myocardial infarction in a prospective, observational, cohort study (2008-2012) of 3501 patients with acute myocardial infarction, 18 to 55 years of age, as part of the VIRGO (Variation in Recovery: Role of Gender on Outcomes of Young AMI Patients) study at 103 US and 24 Spanish hospitals enrolling in a 2:1 ratio for women/men. We created a multivariable logistic regression model to assess the relationship between reperfusion delay (door-to-balloon time >90 or >120 minutes for transfer or door-to-needle time >30 minutes) and electrocardiographic characteristics, adjusting for sex, sociodemographic characteristics, and clinical characteristics at presentation. In our study (834 women and 525 men), women were more likely to exceed reperfusion time guidelines than men (42.4% versus 31.5%; P <0.01). In multivariable analyses, female sex persisted as an important factor in exceeding reperfusion guidelines after adjusting for electrocardiographic characteristics (odds ratio, 1.57; 95% CI, 1.15-2.15). Positive voltage criteria for left ventricular hypertrophy and absence of a prehospital ECG were positive predictors of reperfusion delay; and ST elevation in lateral leads was an inverse predictor of reperfusion delay. Sex disparities in timeliness to reperfusion in young patients with ST-segment-elevation myocardial infarction persisted, despite adjusting for initial electrocardiographic characteristics. Left ventricular hypertrophy by voltage criteria and absence of prehospital ECG are strongly positively correlated and ST elevation in lateral leads is negatively correlated with reperfusion delay. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Canclini, S; Terzi, A; Rossini, P; Vignati, A; La Canna, G; Magri, G C; Pizzocaro, C; Giubbini, R
2001-01-01
Multigated radionuclide ventriculography (MUGA) is a simple and reliable tool for the assessment of global systolic and diastolic function and in several studies it is still considered a standard for the assessment of left ventricular ejection fraction. However the evaluation of regional wall motion by MUGA is critical due to two-dimensional imaging and its clinical use is progressively declining in favor of echocardiography. Tomographic MUGA (T-MUGA) is not widely adopted in clinical practice. The aim of this study was to compare T-MUGA to planar MUGA (P-MUGA) for the assessment of global ejection fraction and to transthoracic echocardiography for the evaluation of regional wall motion. A 16-segment model was adopted for the comparison with echo regional wall motion. For each one of the 16 segments the normal range of T-MUGA ejection fraction was quantified and a normal data file was defined; the average value -2.5 SD was used as the lower threshold to identify abnormal segments. In addition, amplitude images from Fourier analysis were quantified and considered abnormal according to three different thresholds (25, 50 and 75% of the maximum). In a study group of 33 consecutive patients the ejection fraction values of T-MUGA highly correlated with those of P-MUGA (r = 0.93). The regional ejection fraction (according to the normal database) and the amplitude analysis (50% threshold) allowed for the correct identification of 203/226 and 167/226 asynergic segments by echocardiography, and of 269/302 and 244/302 normal segments, respectively. Therefore sensitivity, specificity and overall accuracy to detect regional wall motion abnormalities were 90, 89, 89% and 74, 81, 79% for regional ejection fraction and amplitude analysis, respectively. T-MUGA is a reliable tool for regional wall motion evaluation, well correlated with echocardiography, less subjective and able to provide quantitative data.
Andrews, Christopher M; Srinivasan, Neil T; Rosmini, Stefania; Bulluck, Heerajnarain; Orini, Michele; Jenkins, Sharon; Pantazis, Antonis; McKenna, William J; Moon, James C; Lambiase, Pier D; Rudy, Yoram
2017-07-01
Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a significant cause of sudden cardiac death in the young. Improved noninvasive assessment of ARVC and better understanding of the disease substrate are important for improving patient outcomes. We studied 20 genotyped ARVC patients with a broad spectrum of disease using electrocardiographic imaging (a method for noninvasive cardiac electrophysiology mapping) and advanced late gadolinium enhancement cardiac magnetic resonance scar imaging. Compared with 20 healthy controls, ARVC patients had longer ventricular activation duration (median, 52 versus 42 ms; P =0.007) and prolonged mean epicardial activation-recovery intervals (a surrogate for local action potential duration; median, 275 versus 241 ms; P =0.014). In these patients, we observed abnormal and varied epicardial activation breakthrough locations and regions of nonuniform conduction and fractionated electrograms. Nonuniform conduction and fractionated electrograms were present in the early concealed phase of ARVC. Electrophysiological abnormalities colocalized with late gadolinium enhancement scar, indicating a relationship with structural disease. Premature ventricular contractions were common in ARVC patients with variable initiation sites in both ventricles. Premature ventricular contraction rate increased with exercise, and within anatomic segments, it correlated with prolonged repolarization, electric markers of scar, and late gadolinium enhancement (all P <0.001). Electrocardiographic imaging reveals electrophysiological substrate properties that differ in ARVC patients compared with healthy controls. A novel mechanistic finding is the presence of repolarization abnormalities in regions where ventricular ectopy originates. The results suggest a potential role for electrocardiographic imaging and late gadolinium enhancement in early diagnosis and noninvasive follow-up of ARVC patients. © 2017 American Heart Association, Inc.
Myocardial scar segmentation from magnetic resonance images using convolutional neural network
NASA Astrophysics Data System (ADS)
Zabihollahy, Fatemeh; White, James A.; Ukwatta, Eranga
2018-02-01
Accurate segmentation of the myocardial fibrosis or scar may provide important advancements for the prediction and management of malignant ventricular arrhythmias in patients with cardiovascular disease. In this paper, we propose a semi-automated method for segmentation of myocardial scar from late gadolinium enhancement magnetic resonance image (LGE-MRI) using a convolutional neural network (CNN). In contrast to image intensitybased methods, CNN-based algorithms have the potential to improve the accuracy of scar segmentation through the creation of high-level features from a combination of convolutional, detection and pooling layers. Our developed algorithm was trained using 2,336,703 image patches extracted from 420 slices of five 3D LGE-MR datasets, then validated on 2,204,178 patches from a testing dataset of seven 3D LGE-MR images including 624 slices, all obtained from patients with chronic myocardial infarction. For evaluation of the algorithm, we compared the algorithmgenerated segmentations to manual delineations by experts. Our CNN-based method reported an average Dice similarity coefficient (DSC), precision, and recall of 94.50 +/- 3.62%, 96.08 +/- 3.10%, and 93.96 +/- 3.75% as the accuracy of segmentation, respectively. As compared to several intensity threshold-based methods for scar segmentation, the results of our developed method have a greater agreement with manual expert segmentation.
Characterizing the spectrum of right ventricular remodelling in response to chronic training.
Sitges, Marta; Merino, Beatriz; Butakoff, Constatine; de la Garza, Maria Sanz; Paré, Carles; Montserrat, Silvia; Vidal, Barbara; Azqueta, Manel; Sarquella, Georgia; Gutierrez, Josep Antoni; Canal, Ramon; Brugada, Josep; Bijnens, Bart H
2017-03-01
The significance and spectrum of reduced right ventricular (RV) deformation, reported in endurance athletes, is unclear. To comprehensively analyze the cardiac performance at rest of athletes, especially focusing on integrating RV size and deformation to unravel the underlying triggers of this ventricular remodelling. Hundred professional male athletes and 50 sedentary healthy males of similar age were prospectively studied. Conventional echocardiographic parameters of all four chambers were obtained, as well as 2D echo-derived strain (2DSE) in the left (LV) and in the RV free wall with separate additional analysis of the RV basal and apical segments. Left and right-sided dimensions were larger in athletes than in controls, but with a disproportionate RA enlargement. RV global strain was lower in sportsmen (-26.8 ± 2.8% vs -28.5 ± 3.4%, p < 0.001) due to a decrease in the basal segment (-22.8 ± 3.5% vs -25.8 ± 4.0%, p < 0.001) resulting in a marked gradient of deformation from the RV inlet towards the apex. By integrating size, deformation and stroke volume, we observed that the LV working conditions were similar in all sportsmen while a wider variability existed in the RV. Cardiac remodelling in athletes is more pronounced in the right heart cavities with specific regional differences within the right ventricle, but with a wide variability among individuals. The large inter-individual differences, as well as its acute and chronic relevance warrant further investigation.
White matter injury detection in neonatal MRI
NASA Astrophysics Data System (ADS)
Cheng, Irene; Hajari, Nasim; Firouzmanesh, Amirhossein; Shen, Rui; Miller, Steven; Poskitt, Ken; Basu, Anup
2013-02-01
Early detection of white matter injury in premature newborns can facilitate timely clinical treatments reducing the potential risk of later developmental deficits. It was reported that there were more than 5% premature newborns in British Columbia, Canada, among which 5-10% exhibited major motor deficits and 25-50% exhibited significant developmental and visual deficits. With the advancement of computer assisted detection systems, it is possible to automatically identify white matter injuries, which are found inside the grey matter region of the brain. Atlas registration has been suggested in the literature to distinguish grey matter from the soft tissues inside the skull. However, our subjects are premature newborns delivered at 24 to 32 weeks of gestation. During this period, the grey matter undergoes rapid changes and differs significantly from one to another. Besides, not all detected white spots represent injuries. Additional neighborhood information and expert input are required for verification. In this paper, we propose a white matter feature identification system for premature newborns, which is composed of several steps: (1) Candidate white matter segmentation; (2) Feature extraction from candidates; (3) Validation with data obtained at a later stage on the children; and (4) Feature confirmation for automated detection. The main challenge of this work lies in segmenting white matter injuries from noisy and low resolution data. Our approach integrates image fusion and contrast enhancement together with a fuzzy segmentation technique to achieve promising results. Other applications, such as brain tumor and intra-ventricular haemorrhage detection can also benefit from our approach.
Electrocardiographic evaluation of reperfusion therapy in patients with acute myocardial infarction.
Clemmensen, P
1996-02-01
The present thesis is based on 6 previously published clinical studies in patients with AMI. Thrombolytic therapy for patients with AMI improves early infarct coronary artery patency, limits AMI size, improves left ventricular function and survival, as demonstrated in large placebo-controlled clinical trials. With the advent of interventions aimed at limiting AMI size it became important to assess the amount of ischemic myocardium in the early phase of AMI, and to develop noninvasive methods for evaluation of these therapies. The aims of the present studies were to develop such methods. The studies have included 267 patients with AMI admitted up to 12 hours after onset of symptoms. All included patients had acute ECG ST-segment changes indicating subepicardial ischemia, and patients with bundle branch block were excluded. Serial ECG's were analyzed with quantitative ST-segment measurements in the acute phase and compared to the Selvester QRS score estimated final AMI size. These ECG indices were compared to and validated through comparisons with other independent noninvasive and invasive methods, used for the purpose of evaluating patients with AMI treated with thrombolytic therapy. It was found that in patients with first AMI not treated with reperfusion therapies the QRS score estimated final AMI size can be predicted from the acute ST-segment elevation. Based on the number of ECG leads with ST-segment elevation and its summated magnitude, formulas were developed to provide an "ST score" for estimating the amount of myocardium in jeopardy during the early phase of AMI. The ST-segment deviation present in the ECG in patients with documented occlusion of the infarct related coronary artery, was subsequently shown to correlate with the degree of regional and global left ventricular dysfunction. Because serial changes in ST-segment elevation, during the acute phase of AMI were believed to reflect changes is myocardial ischemia and thus possibly infarct artery patency status, the summated ST-segment elevation present on the admission ECG was compared to that present after administration of intravenous thrombolytic therapy, and immediately prior to angiographic visualization of the infarct related coronary artery. The entire spectrum of sensitivities and specificities, derived from different cut-off values for the degree of ST-segment normalization, was described for the first time. It was found that a 20% decrease in ST-segment elevation could predict coronary artery patency with a high level of accuracy: positive predictive value = 88% and negative predictive value = 80%.(ABSTRACT TRUNCATED)
Real-time segmentation in 4D ultrasound with continuous max-flow
NASA Astrophysics Data System (ADS)
Rajchl, M.; Yuan, J.; Peters, T. M.
2012-02-01
We present a novel continuous Max-Flow based method to segment the inner left ventricular wall from 3D trans-esophageal echocardiography image sequences, which minimizes an energy functional encoding two Fisher-Tippett distributions and a geometrical constraint in form of a Euclidean distance map in a numerically efficient and accurate way. After initialization the method is fully automatic and is able to perform at up to 10Hz making it available for image-guided interventions. Results are shown on 4D TEE data sets from 18 patients with pathological cardiac conditions and the speed of the algorithm is assessed under a variety of conditions.
Left ventricular endocardial surface detection based on real-time 3D echocardiographic data
NASA Technical Reports Server (NTRS)
Corsi, C.; Borsari, M.; Consegnati, F.; Sarti, A.; Lamberti, C.; Travaglini, A.; Shiota, T.; Thomas, J. D.
2001-01-01
OBJECTIVE: A new computerized semi-automatic method for left ventricular (LV) chamber segmentation is presented. METHODS: The LV is imaged by real-time three-dimensional echocardiography (RT3DE). The surface detection model, based on level set techniques, is applied to RT3DE data for image analysis. The modified level set partial differential equation we use is solved by applying numerical methods for conservation laws. The initial conditions are manually established on some slices of the entire volume. The solution obtained for each slice is a contour line corresponding with the boundary between LV cavity and LV endocardium. RESULTS: The mathematical model has been applied to sequences of frames of human hearts (volume range: 34-109 ml) imaged by 2D and reconstructed off-line and RT3DE data. Volume estimation obtained by this new semi-automatic method shows an excellent correlation with those obtained by manual tracing (r = 0.992). Dynamic change of LV volume during the cardiac cycle is also obtained. CONCLUSION: The volume estimation method is accurate; edge based segmentation, image completion and volume reconstruction can be accomplished. The visualization technique also allows to navigate into the reconstructed volume and to display any section of the volume.
Finite Element Analysis of Stresses Developed in the Blood Sac of a Left Ventricular Assist Device
Haut Donahue, T. L.; Dehlin, W.; Gillespie, J.; Weiss, W.J.; Rosenberg, G.
2009-01-01
The goal of this research is to develop a 3D finite element (FE) model of a left ventricular assist device (LVAD) to predict stresses in the blood sac. The hyperelastic stress-strain curves for the segmented poly(ether polyurethane urea) blood sac were determined in both tension and compression using a servo-hydraulic testing system at various strain rates. Over the range of strain rates studied, the sac was not strain rate sensitive, however the material response was different for tension versus compression. The experimental tension and compression properties were used in a FE model that consisted of the pusher plate, blood sac and pump case. A quasi-static analysis was used to allow for nonlinearities due to contact and material deformation. The 3D FE model showed that blood sac stresses are not adversely affected by the location of the inlet and outlet ports of the device and that over the systolic ejection phase of the simulation the prediction of blood sac stresses from the full 3D model and an axisymmetric model are the same. Minimizing stresses in the blood sac will increase the longevity of the blood sac in vivo. PMID:19131267
NASA Astrophysics Data System (ADS)
Kishimoto, J.; Lee, D.; St. Lawrence, K.; Romano, W.; Fenster, A.; de Ribaupierre, S.
2013-03-01
Clinical intracranial ultrasound (US) is performed as a standard of care on neonates at risk of intraventricular hemorrhaging (IVH) and is also used after a diagnosis to monitor for potential ventricular dilation. However, it is difficult to estimate the volume of ventricles with 2D US due to their irregular shape. We developed a 3D US system to be used as an adjunct to a clinical system to investigate volumetric changes in the ventricles of neonates with IVH. Our system has been found have an error of within 1% of actual distance measurements in all three directions and volume measurements of manually segmented volumes from phantoms were not statistically significantly different from the actual values (p>0.3). Interobserver volume measurements of the lateral ventricles in a patient with grade III IVH found no significant differences between measurements. There is the potential to use this system in IVH patients to monitor the progression of ventriculomegaly over time.
Karpati, G; Zubrzycka-Gaarn, E E; Carpenter, S; Bulman, D E; Ray, P N; Worton, R G
1990-03-01
Immunoreactive dystrophin was examined in muscle fibers of quadriceps, extraocular muscles and cardiac ventricular muscles of female heterozygote mdx mice at 10, 35 and 60 days of age, with microscopic immunoperoxidase method and by immunoblots. In quadriceps muscle fibers there was a marked gradual diminution of the dystrophin-negative fiber segments between age 10 and 60 days. We suggest that this was partly due to a spontaneous fusion of dystrophin-competent satellite cells into the dystrophin-negative fiber segments and partly to an expansion of the cytoplasmic domain of dystrophin expression related to the original myonuclei. In cardiac muscle that lacks satellite cells, there was persistence of a large number of dystrophin-negative fiber segments even at age 60 days and probably beyond. The findings of this study have implications for the detection of heterozygote female carriers of Duchenne muscular dystrophy (DMD) and for the possible therapy of DMD muscles by myoblast transfer.
Mirvis, D M
1988-11-01
Patients with acute inferior myocardial infarction commonly have ST segment depression in the anterior precordial leads. This may reflect either reciprocal changes from the inferior ST elevation or primary ST depression from additional anterior subendocardial ischemia. From a biophysical perspective reciprocal changes should be uniformly anticipated from basic dipole theory. Detection will vary with the size, location, orientation, and electrical intensity of the lesion and with the ECG lead system deployed to register the anterior changes. Alternatively, acute occlusion of the right coronary artery may produce ischemia in the anterior left ventricular wall supplied by a stenotic anterior descending coronary artery. Anterior ischemia may result from the abnormal hemodynamics or the reduced collateral flow produced by acute right coronary artery occlusion. Thus both mechanisms are based on sound physiologic principles. A review of the clinical literature suggests that such patients represent a heterogeneous group. In some instances coexistent anterior ischemia is present, whereas in others the anterior ST depression is the passive reflection of inferior ST elevation augmented in many cases by a large infarct size or more extensive posterobasal or septal involvement.
Zhang, Hai-Bo; Meng, Xu; Han, Jie; Li, Yan; Zhang, Ye; Jiang, Teng-Yong; Zhao, Ying-Xin; Zhou, Yu-Jie
2017-04-01
Transvenous lead placement is the standard approach for left ventricular (LV) pacing in cardiac resynchronization therapy (CRT), while the open chest access epicardial lead placement is currently the most frequently used second choice. Our study aimed to compare the ventricular electromechanical synchronicity in patients with heart failure after CRT with these two different LV pacing techniques. We enrolled 33 consecutive patients with refractory heart failure secondly to dilated cardiomyopathy who were eligible for CRT in this study. Nineteen patients received transvenous (TV group) while 14 received open chest (OP group) LV lead pacing. Intra- and inter-ventricular electromechanical synchronicity was assessed by tissue Doppler imaging (TDI) before and one year after CRT procedure. Before CRT procedure, the mean QRS-duration, maximum time difference to systolic peak velocity among 12 left ventricle segments (LV Ts-12), standard deviation of time difference to systolic peak velocity of 12 left ventricle segments (LV Ts-SD), and inter-ventricular mechanical delay (IVMD) in OP and TV group were 166 ± 17 ms and 170 ± 21 ms, 391 ± 42 ms and 397 ± 36 ms, 144 ± 30 ms and 148 ± 22 ms, 58 ± 25 ms and 60 ± 36 ms, respectively (all P > 0.05). At one year after the CRT, the mean QRS-duration, LV Ts-12, LV Ts-SD, and IVMD in TV and OP group were 128 ± 14 ms and 141 ± 22 ms ( P = 0.031), 136 ± 37 ms and 294 ± 119 ms ( P = 0.023), 50 ± 22 ms and 96 ± 34 ms ( P = 0.015), 27 ± 11 ms and 27 ± 26 ms ( P = 0.86), respectively. The LV lead implantation procedure time was 53.4 ± 16.3 min for OP group and 136 ± 35.1 min for TV group ( P = 0.016). The mean LV pacing threshold increased significantly from 1.7 ± 0.6 V/0.5 ms to 2.3 ± 1.6 V/0.5 ms ( P < 0.05) in TV group while it remained stable in the OP group. Compared to conventional endovascular approach, open chest access of LV pacing for CRT leads to better improvement of the intraventricular synchronization.
Gimelli, Alessia; Masci, Pier Giorgio; Liga, Riccardo; Grigoratos, Chrysanthos; Pasanisi, Emilio Maria; Lombardi, Massimo; Marzullo, Paolo
2014-09-01
To assess the relationships between myocardial structure and function on cardiac magnetic resonance (CMR) imaging and sympathetic tone on (123)I-metaiodobenzylguanidine ((123)I-MIBG) scintigraphy early after myocardial infarction (MI). Ten patients underwent (123)I-MIBG and (99m)Tc-tetrofosmin rest cadmium zinc telluride scintigraphy 4 ± 1 days after MI. The segmental left ventricular (LV) relative radiotracer uptake of both (99m)Tc-tetrofosmin and early (123)I-MIBG was calculated. The day after scintigraphy, on CMR imaging, the extent of ischaemia-related oedema and of myocardial fibrosis (late gadolinium enhancement, LGE) was assessed. Accordingly, the extent of oedema and LGE was evaluated for each segment and segmental wall thickening determined. Based on LGE distribution, LV segments were categorized as "infarcted" (56 segments), "adjacent" (66 segments) or "remote" (48 segments). Infarcted segments showed a more depressed systolic wall thickening and greater extent of oedema than adjacent segments (p < 0.001) and remote segments (p < 0.001). Interestingly, while uptake of (99m)Tc-tetrofosmin was significantly depressed only in infarcted segments (p < 0.001 vs. both adjacent and remote segments), uptake of (123)I-MIBG was impaired not only in infarcted segments (p < 0.001 vs. remote) but also in adjacent segments (p = 0.024 vs. remote segments). At the regional level, after correction for (99m)Tc-tetrofosmin and LGE distribution, segmental (123)I-MIBG uptake (p < 0.001) remained an independent predictor of ischaemia-related oedema. After acute MI the regional impairment of sympathetic tone extends beyond the area of altered myocardial perfusion and is associated with myocardial oedema.
Lunkenheimer, Paul Peter; Niederer, Peter
2012-01-01
In order to visualise the mammalian myocardial structure in its entirety, we distended excised porcine left ventricles by inflating the coronary arteries with compressed air, using rising pressures between 100 and 300 kPa. The ventricular walls became elongated, and left ventricular cavity widened with rising pressure albeit with insignificant changes in their mural thickness. High resolution computed tomographic analysis subsequent to pneumographic distension revealed a hierarchical structure. First, a feathered arrangement of the cardiomyocytes aggregated together mainly within the equatorial area of the ventricle, giving an overall appearance of systematically arranged spatially netted lamellar structures with pronounced local inhomogeneity. Second, histological examination in orthogonal planes, analysing samples dividing the ventricular walls into 18 segments, showed the lamellae themselves to be made up of aggregated chains of myocytes, the alignment of these chains producing the well-recognised change in so-called helical angle when traced through the thickness of the walls. Transmural length sections removed from the same positions in the ventricular walls showed inter-lamellar connections aligned in the direction from the ventricular base to the apex which were definitely longer than those we observed in transmural cross-sections. Electron-microscopy exposed the two compartments of interstitial connective tissue, suggesting the endomysium to bind long chains of myocytes to lamellar aggregates, while the loose perimysium strengthens the structure of the lubricating medium which eases the gliding of the lamellar aggregates relative to one another.
Evaluation of left ventricular function by bedside ultrasound in acute toxic myocarditis.
Brown, Cara; Budhram, Gavin
2013-10-01
Myocarditis can be difficult to diagnose in the Emergency Department (ED) due to the lack of classic symptoms and the wide variation in presentations. Poor cardiac contractility is a common finding in myocarditis and can be evaluated by bedside ultrasound. To demonstrate the utility of fractional shortening measurements as an estimation of left ventricular function during bedside cardiac ultrasound evaluation in the ED. A 54-year-old man presented to the ED complaining of 3 days of chest tightness, palpitations, and dyspnea, as well as persistent abdominal pain and vomiting. An electrocardiogram (ECG) showed sinus tachycardia with presumably new ST-segment elevation and signs of an incomplete right bundle branch block. A bedside echocardiogram was performed by the emergency physician that showed poor left ventricular function by endocardial fractional shortening measurements. On further questioning, the patient revealed that for the past 2 weeks he had been regularly huffing a commercially available compressed air duster. Based on these history and examination findings, the patient was given a presumptive diagnosis of toxic myocarditis. A follow-up echocardiogram approximately 7 weeks later demonstrated resolution of the left ventricular systolic dysfunction and his ECG findings normalized. Cardiac ultrasound findings of severely reduced global function measured by endocardial fractional shortening were seen in this patient and supported the diagnosis of myocarditis. Endocardial fractional shortening is a useful means of easily evaluating and documenting left ventricular function and can be performed at the bedside in the ED. Copyright © 2013 Elsevier Inc. All rights reserved.
Methamphetamine-associated cardiomyopathy: patterns and predictors of recovery.
Voskoboinik, A; Ihle, J F; Bloom, J E; Kaye, D M
2016-06-01
Methamphetamine abuse is a growing public health problem, and increasing numbers of patients are admitted with methamphetamine-associated cardiomyopathy (MAC). We sought to characterise the patterns of this disease and identify predictors of recovery. We retrospectively studied consecutive patients diagnosed with MAC between January 2006 and July 2015. We identified 20 patients (14 males, 6 females) with mean age 35 ± 9 years. Most had very severe systolic dysfunction (mean left ventricular ejection fraction (LVEF) 19.7 ± 11.4%) at presentation with 14 requiring inotropes and 5 requiring mechanical support. The pattern of systolic dysfunction was global in 14 patients, while 6 patients had a 'reverse Takotsubo' (RT) pattern with severely hypokinetic basal-mid segments and apical preservation. RT patients were predominantly female, had a short history of methamphetamine abuse and had higher cardiac enzyme levels. Patients with global dysfunction tended to have mid-wall fibrosis on cardiac magnetic resonance imaging. On follow-up transthoracic echocardiography, 6 out of 19 (32%) had normalisation of LVEF (LVEF ≥ 50%) within 6 weeks. Smaller left ventricular and left atrial size, shorter duration of methamphetamine use and RT pattern appeared to predict early recovery. A subset of MAC patients, particularly those with a RT pattern and lesser ventricular dilatation have the potential for early recovery of ventricular function. By contrast, those with evidence of myocardial fibrosis and ventricular enlargement have limited scope for recovery. © 2016 Royal Australasian College of Physicians.
Krivec, B; Voga, G; Zuran, I; Skale, R; Pareznik, R; Podbregar, M; Noc, M
1997-11-05
To evaluate the diagnostic value of transesophageal echocardiography (TEE) as an initial diagnostic tool in shocked patients. The second objective was to study therapeutic impact of intrapulmonary thrombolysis in patients with diagnosed massive pulmonary embolism. Prospective observational study. Medical ICU in 800-bed general hospital. Twenty-four consecutive patients with unexplained shock and distended jugular veins. In 18 patients, right ventricular dilatation with global or segmental hypokinesis was documented. In addition, central pulmonary thromboemboli (12 patients), reduced contrast flow in right pulmonary artery (one patient), and right ventricular free wall akinesis (one patient) were found. No additional echocardiographic findings were apparent in four patients. According to pulmonary scintigraphy or autopsy, sensitivity of TEE for diagnosis of massive pulmonary embolism (MPE) in patients with right ventricular dilatation was 92% and specificity was 100%. In patients without right ventricular dilatation, left ventricular dysfunction (four patients) or cardiac tamponade (two patients) was confirmed. Intrapulmonary thrombolysis was evaluated in 11 of 13 patients with MPE. Two patients died prior to attempted thrombolysis. Three patients received streptokinase and eight received urokinase. Twenty-four hours after beginning of treatment, total pulmonary resistance index significantly decreased for 59% and mean pulmonary artery pressure for 31%. Cardiac index increased for 74%. Nine of 11 patients receiving thrombolysis survived to hospital discharge. Bedside TEE is a valuable tool for diagnosis of MPE. It enables immediate intrapulmonary thrombolysis, which seems to be an effective therapeutic alternative in our group of patients with obstructive shock.
Novel echocardiographic prediction of non-response to cardiac resynchronization therapy
NASA Astrophysics Data System (ADS)
Chan, R.; Tournoux, F.; Tournoux, A. C.; Nandigam, V.; Manzke, R.; Dalal, S.; Solis-Martin, J.; McCarty, D.; Ruskin, J. N.; Picard, M. H.; Weyman, A. E.; Singh, J. P.
2009-02-01
Imaging techniques try to identify patients who may respond to cardiac resynchronization therapy (CRT). However, it may be clinically more useful to identify patients for whom CRT would not be beneficial as the procedure would not be indicated for this group. We developed a novel, clinically feasible and technically-simple echocardiographic dyssynchrony index and tested its negative predictive value. Subjects with standard indications for CRT had echo preand post-device implantation. Atrial-ventricular dyssynchrony was defined as a left ventricular (LV) filling time of <40% of the cardiac cycle. Intra-ventricular dyssynchrony was quantified as the magnitude of LV apical rocking. The apical rocking was measured using tissue displacement estimates from echo data. In a 4-chamber view, a region of interest was positioned within the apical end of the middle segment within each wall. Tissue displacement curves were analyzed with custom software in MATLAB. Rocking was quantified as a percentage of the cardiac cycle over which the displacement curves showed discordant behavior and classified as non-significant for values <35%. Validation in 50 patients showed that absence of significant LV apical rocking or atrial-ventricular dyssynchrony was associated with non-response to CRT. This measure may therefore be useful in screening to avoid non-therapeutic CRT procedures.
de Knegt, Martina Chantal; Fuchs, A; Weeke, P; Møgelvang, R; Hassager, C; Kofoed, K F
2016-12-01
Current echocardiographic assessments of coronary vascular territories use the 17-segment model and are based on general assumptions of coronary vascular distribution. Fusion of 3D echocardiography (3DE) with multidetector computed tomography (MDCT) derived coronary anatomy may provide a more accurate assessment of left ventricular (LV) territorial function. We aimed to test the feasibility of MDCT and 3DE fusion and to compare territorial longitudinal strain (LS) using the 17-segment model and a MDCT-guided vascular model. 28 patients underwent 320-slice MDCT and transthoracic 3DE on the same day followed by invasive coronary angiography. MDCT (Aquilion ONE, ViSION Edition, Toshiba Medical Systems) and 3DE apical full-volume images (Artida, Toshiba Medical Systems) were fused offline using a dedicated workstation (prototype fusion software, Toshiba Medical Systems). 3DE/MDCT image alignment was assessed by 3 readers using a 4-point scale. Territorial LS was assessed using the 17-segment model and the MDCT-guided vascular model in territories supplied by significantly stenotic and non-significantly stenotic vessels. Successful 3DE/MDCT image alignment was obtained in 86 and 93 % of cases for reader one, and reader two and three, respectively. Fair agreement on the quality of automatic image alignment (intra-class correlation = 0.40) and the success of manual image alignment (Fleiss' Kappa = 0.40) among the readers was found. In territories supplied by non-significantly stenotic left circumflex arteries, LS was significantly higher in the MDCT-guided vascular model compared to the 17-segment model: -15.00 ± 7.17 (mean ± standard deviation) versus -11.87 ± 4.09 (p < 0.05). Fusion of MDCT and 3DE is feasible and provides physiologically meaningful displays of myocardial function.
Shen, Jiaqi; Zhou, Qiao; Liu, Yue; Luo, Runlan; Tan, Bijun; Li, Guangsen
2016-08-23
Iron-deficiency anemia (IDA) is a global health problem and a common medical condition that can be seen in everyday clinical practice. And two-dimensional speckle tracking echocardiography (2D-STE) has been reported very useful in evaluating left atrial (LA) function, as well as left ventricular (LV) function. The aim of our study is to evaluate the LA function in patients with IDA by 2D-STE. 65 patients with IDA were selected. This group of patients was then divided into two groups according to the degree of hemoglobin: group B (Hb > 90 g/L) and group C (Hb60 ~ 90 g/L). Another 30 healthy people were also selected as control group A. Conventional echocardiography parameters, such as left atrial diameter (LAD), peak E and A of mitralis (E, A), E/A, end-diastolic thickness of ventricular septum (IVST d), end-diastolic thickness of LV posterior wall (PWTd) and left ventricular end-diastolic dimension (LVDd) were obtained from these three groups. Left atrial minimum volume (LAVmin), left atrial pre-atrial contraction volume (LAVp) and left atrial maximum volume (LAVmax) were measured by Simpson's rule, whereas left atrial active ejection fraction (LAAEF) and left atrial passive ejection fraction (LAPEF) were obtained from calculation. Two-dimensional images were acquired from apical four-chamber view and two-chamber view to store images for offline analysis. The global peak atrial longitudinal strain and strain rate of systolic LV (GLSs, GLSRs) as well as early and late diastolic LV strain rate (GLSRe, GLSRa) curves of LA were acquired in each LA segment from basal segment to top segment of LA by 2D-STE. Compared with group A, there were no differences between group B and group A (all P > 0.05). The LAAEF and GLSRa were significantly higher in group C compared with those of group A and group B (all P < 0.01). The LAPEF, GLSs, GLSRs and GLSRe were significantly lower in group C compared with those of group A and group B (all P < 0.01). 2D-STE could evaluate the LA function in patients with IDA.
Wharton, J; Anderson, R H; Springall, D; Power, R F; Rose, M; Smith, A; Espejo, R; Khaghani, A; Wallwork, J; Yacoub, M H
1988-01-01
Atrial natriuretic peptide immunoreactivity was found in ventricular and atrial tissues with specific antisera raised to the amino and carboxy terminal regions of the precursor molecule. In 13 developing human hearts (7-24 weeks' gestation) the immunoreactivity was concentrated in the atrial myocardium and ventricular conduction system but it was also detected in the early fetal ventricular myocardium. Immunoreactivity in five normal adults was largely confined to the atrial myocardium although it was also found in the ventricular conduction tissues of hearts removed from 10 patients who were undergoing cardiac transplantation. The ventricular conduction system is an extra-atrial site for the synthesis of atrial natriuretic peptide. In the failing heart this synthesis may be further supplemented by expression of the gene in the ventricular myocardium. It is possible that ventricular production of the peptide contributes to the raised circulating concentrations of atrial natriuretic peptide immunoreactivity found in severe congestive heart disease, particularly in patients with dilated cardiomyopathy. Images Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 PMID:2973340
Virtual Cerebral Ventricular System: An MR-Based Three-Dimensional Computer Model
ERIC Educational Resources Information Center
Adams, Christina M.; Wilson, Timothy D.
2011-01-01
The inherent spatial complexity of the human cerebral ventricular system, coupled with its deep position within the brain, poses a problem for conceptualizing its anatomy. Cadaveric dissection, while considered the gold standard of anatomical learning, may be inadequate for learning the anatomy of the cerebral ventricular system; even with…
NASA Astrophysics Data System (ADS)
Aziz, Aamer; Hu, Qingmao; Nowinski, Wieslaw L.
2004-04-01
The human cerebral ventricular system is a complex structure that is essential for the well being and changes in which reflect disease. It is clinically imperative that the ventricular system be studied in details. For this reason computer assisted algorithms are essential to be developed. We have developed a novel (patent pending) and robust anatomical knowledge-driven algorithm for automatic extraction of the cerebral ventricular system from MRI. The algorithm is not only unique in its image processing aspect but also incorporates knowledge of neuroanatomy, radiological properties, and variability of the ventricular system. The ventricular system is divided into six 3D regions based on the anatomy and its variability. Within each ventricular region a 2D region of interest (ROI) is defined and is then further subdivided into sub-regions. Various strict conditions that detect and prevent leakage into the extra-ventricular space are specified for each sub-region based on anatomical knowledge. Each ROI is processed to calculate its local statistics, local intensity ranges of cerebrospinal fluid and grey and white matters, set a seed point within the ROI, grow region directionally in 3D, check anti-leakage conditions and correct growing if leakage occurs and connects all unconnected regions grown by relaxing growing conditions. The algorithm was tested qualitatively and quantitatively on normal and pathological MRI cases and worked well. In this paper we discuss in more detail inclusion of anatomical knowledge in the algorithm and usefulness of our approach from clinical perspective.
Sharma, Ravi K; Donekal, Sirisha; Rosen, Boaz D; Tattersall, Matthew C; Volpe, Gustavo J; Ambale-Venkatesh, Bharath; Nasir, Khurram; Wu, Colin O; Polak, Joseph F; Korcarz, Claudia E; Stein, James H; Carr, James; Watson, Karol E; Bluemke, David A; Lima, João A C
2015-04-01
The role of atherosclerosis in the progression of global left ventricular dysfunction and cardiovascular events has been well recognized. Left ventricular (LV) dyssynchrony is a measure of regional myocardial dysfunction. Our objective was to investigate the relationship of subclinical atherosclerosis with mechanical LV dyssynchrony in a population-based asymptomatic multi-ethnic cohort. Participants of the Multi-Ethnic Study of Atherosclerosis (MESA) at exam 5 were evaluated using 1.5T cardiac magnetic resonance (CMR) imaging, carotid ultrasound (n = 2062) for common carotid artery (CCA) and internal carotid artery (ICA) intima-media thickness (IMT), and cardiac computed tomography (n = 2039) for coronary artery calcium (CAC) assessment (Agatston method). Dyssynchrony indices were defined as the standard deviation of time to peak systolic circumferential strain (SD-TPS) and the difference between maximum and minimum (max-min) time to peak strain using harmonic phase imaging in 12 segments (3-slices × 4 segments). Multivariable regression analyses were performed to assess associations after adjusting for participant demographics, cardiovascular risk factors, LV mass, and ejection fraction. In multivariable analyses, SD-TPS was significantly related to measures of atherosclerosis, including CCA-IMT (8.7 ms/mm change in IMT, p = 0.020), ICA-IMT (19.2 ms/mm change in IMT, p < 0.001), carotid plaque score (1.2 ms/unit change in score, p < 0.001), and log transformed CAC+1 (0.66 ms/unit log-CAC+1, p = 0.018). These findings were consistent with other parameter of LV dyssynchrony i.e. max-min. In the MESA cohort, measures of atherosclerosis are associated with parameters of subclinical LV dyssynchrony in the absence of clinical coronary event and left-bundle-branch block. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Stiermaier, Thomas; Pöss, Janine; Eitel, Charlotte; de Waha, Suzanne; Fuernau, Georg; Desch, Steffen; Thiele, Holger; Eitel, Ingo
2018-05-16
Left ventricular hypertrophy (LVH) has been suggested as a determinant of outcome in patients with ST-segment elevation myocardial infarction (STEMI). However, available data are inconclusive and the underlying mechanisms remain unclear. Therefore, the aim of this study was to evaluate the impact of LVH on myocardial injury and clinical outcome in a large multicenter STEMI population. Cardiovascular magnetic resonance was performed in 795 patients within 10 days after STEMI to assess left ventricular (LV) mass and parameters of myocardial injury. Gender-specific cutoff values of indexed LV mass were used to define LVH (67 g/m 2 for men and 61 g/m 2 for women). Rates of major adverse cardiac events (MACE) were determined at 12-month follow-up. LVH was present in 438 patients (55%) and associated with a significantly larger infarct size [18.3% of LV mass (%LV) versus 14.0%LV; p < 0.01], a lower myocardial salvage index (47.8 versus 54.4; p < 0.01), larger extent of microvascular obstruction (0.4 versus 0%LV; p < 0.01) and lower LV ejection fraction (47.9 versus 53.2%; p < 0.01) compared to STEMI patients without LVH. The effect of LVH on LV ejection fraction, infarct size and myocardial salvage index remained statistically significant after adjustment for baseline characteristics (p < 0.01 for all). MACE rates at 12 months were numerically higher in patients with versus without LVH without reaching statistical significance (7.5 versus 5.6%; p = 0.32). In STEMI patients, LVH is associated with more pronounced structural and functional alterations in CMR imaging as an indicator for adverse clinical outcomes in STEMI survivors.
Smolarek, Dorota; Gruchała, Marcin; Sobiczewski, Wojciech
2017-01-01
Estimation of right ventricular (RV) performance still remains technically challenging due to its anatomical and functional distinctiveness. The current guidelines for the echocardiographic quantification of RV function recommend using multiple indices to describe the RV in a thorough and comprehensive manner, such as RV index of myocardial performance, tricuspid annular plane systolic excursion, fractional area change, Doppler tissue imaging-derived tricuspid lateral annular systolic velocity (S'-wave), three-dimensional RV ejection fraction (3D RVEF), RV longitudinal strain (RVLS)/strain rate by speckle- tracking echocardiography (STE). Among these, the last one mentioned here is an innovative and a particularly promising tool that yields more precise information about complex regional and global RV mechanics. STE was initially designed to evaluate left ventricular function, but recently it has been introduced to assess RV performance, which is difficult due to its unique structure and physiology. Many studies have shown that both free wall and 6-segment RVLS present a stronger correlation with the RVEF assessed by cardiac magnetic resonance than conventional parameters and seem to be more sensitive in detecting myocardial dysfunction at an earlier, subclinical stage.
Intra-QT spectral coherence as a possible noninvasive marker of sustained ventricular tachycardia.
Piccirillo, Gianfranco; Moscucci, Federica; Persi, Alessandro; Di Barba, Daniele; Pappadà, Maria Antonella; Rossi, Pietro; Quaglione, Raffaele; Nguyen, Bich Lien; Barillà, Francesco; Casenghi, Matteo; Magrì, Damiano
2014-01-01
Sudden cardiac death is the main cause of mortality in patients affected by chronic heart failure (CHF) and with history of myocardial infarction. No study yet investigated the intra-QT phase spectral coherence as a possible tool in stratifying the arrhythmic susceptibility in patients at risk of sudden cardiac death (SCD). We, therefore, assessed possible difference in spectral coherence between the ECG segment extending from the q wave to the T wave peak (QTp) and the one from T wave peak to the T wave end (Te) between patients with and without Holter ECG-documented sustained ventricular tachycardia (VT). None of the QT variability indexes as well as most of the coherences and RR power spectral variables significantly differed between the two groups except for the QTp-Te spectral coherence. The latter was significantly lower in patients with sustained VT than in those without (0.508 ± 0.150 versus 0.607 ± 0.150, P < 0.05). Although the responsible mechanism remains conjectural, the QTp-Te spectral coherence holds promise as a noninvasive marker predicting malignant ventricular arrhythmias.
Intra-QT Spectral Coherence as a Possible Noninvasive Marker of Sustained Ventricular Tachycardia
Piccirillo, Gianfranco; Moscucci, Federica; Di Barba, Daniele; Pappadà, Maria Antonella; Rossi, Pietro; Quaglione, Raffaele; Barillà, Francesco; Magrì, Damiano
2014-01-01
Sudden cardiac death is the main cause of mortality in patients affected by chronic heart failure (CHF) and with history of myocardial infarction. No study yet investigated the intra-QT phase spectral coherence as a possible tool in stratifying the arrhythmic susceptibility in patients at risk of sudden cardiac death (SCD). We, therefore, assessed possible difference in spectral coherence between the ECG segment extending from the q wave to the T wave peak (QTp) and the one from T wave peak to the T wave end (T e) between patients with and without Holter ECG-documented sustained ventricular tachycardia (VT). None of the QT variability indexes as well as most of the coherences and RR power spectral variables significantly differed between the two groups except for the QTp-T e spectral coherence. The latter was significantly lower in patients with sustained VT than in those without (0.508 ± 0.150 versus 0.607 ± 0.150, P < 0.05). Although the responsible mechanism remains conjectural, the QTp-T e spectral coherence holds promise as a noninvasive marker predicting malignant ventricular arrhythmias. PMID:25133170
Ali, Wail; Bubolz, Beth A; Nguyen, Linh; Castro, Danny; Coss-Bu, Jorge; Quach, Michael M; Kennedy, Curtis E; Anderson, Anne E; Lai, Yi-Chen
2017-12-01
Convulsive status epilepticus can exert profound cardiovascular effects in adults including ventricular depolarization-repolarization abnormalities. Whether status epilepticus adversely affects ventricular electrical properties in children is less understood. Therefore, we sought to characterize ventricular alterations and the associated clinical factors in children following convulsive status epilepticus. We conducted a 2-year retrospective, case-control study. Children between 1 month and 21 years of age were included if they were admitted to the pediatric intensive care unit with primary diagnosis of convulsive status epilepticus and had 12-lead electrocardiogram (ECG) within 24 hours of admission. Children with heart disease, ion channelopathy, or on vasoactive medications were excluded. Age-matched control subjects had no history of seizures or epilepsy. The primary outcome was ventricular abnormalities represented by ST segment changes, abnormal T wave, QRS axis deviation, and corrected QT (QTc) interval prolongation. The secondary outcomes included QT/RR relationship, beat-to-beat QTc interval variability, ECG interval measurement between groups, and clinical factors associated with ECG abnormalities. Of 317 eligible children, 59 met the inclusion criteria. History of epilepsy was present in 31 children (epileptic) and absent in 28 children (non-epileptic). Compared with the control subjects (n = 31), the status epilepticus groups were more likely to have an abnormal ECG with overall odds ratio of 3.8 and 7.0 for the non-epileptic and the epileptic groups respectively. Simple linear regression analysis demonstrated that children with epilepsy exhibited impaired dependence and adaptation of the QT interval on heart rate. Beat-to-beat QTc interval variability, a marker of ventricular repolarization instability, was increased in children with epilepsy. Convulsive status epilepticus can adversely affect ventricular electrical properties and stability in children, especially those with epilepsy. These findings suggest that children with epilepsy may be particularly vulnerable to seizure-induced arrhythmias. Therefore postictal cardiac surveillance may be warranted in this population.
Multani, Jasjit Singh; Oermann, Eric Karl; Titano, Joseph; Mascitelli, Justin; Nicol, Kelly; Feng, Rui; Skovrlj, Branko; Pain, Margaret; Mocco, J D; Bederson, Joshua B; Costa, Anthony; Shrivastava, Raj
2017-08-01
There is no facile quantitative method for monitoring hydrocephalus (HCP). We propose quantitative computed tomography (CT) ventriculography (qCTV) as a novel computer vision tool for empirically assessing HCP in patients with subarachnoid hemorrhage (SAH). Twenty patients with SAH who were evaluated for ventriculoperitoneal shunt (VPS) placement were selected for inclusion. Ten patients with normal head computed tomography (CTH) findings were analyzed as negative controls. CTH scans were segmented both manually and automatically (by qCTV) to generate measures of ventricular volume. The median manually calculated ventricular volume was 36.1 cm 3 (interquartile range [IQR], 30-115 cm 3 ), which was similar to the median qCTV measured volume of 37.5 cm 3 (IQR, 32-118 cm 3 ) (P = 0.796). Patients undergoing VPS placement demonstrated an increase in median ventricular volume on qCTV from 21 cm 3 to 40 cm 3 on day T-2 and to 51 cm 3 by day 0, a change of 144%. This is in contrast to patients who did not require shunting, in whom median ventricular volume decreased from 16 cm 3 to 14 cm 3 on day T-2 and to 13 cm 3 by day 0, with an average overall volume decrease 19% (P = 0.001). The average change in ventricular volume predicted which patients would require VPS placement, successfully identifying 7 of 10 patients (P = 0.004). Using an optimized cutoff of a change in ventricular volume of 2.5 cm 3 identified all patients who went on to require VPS placement (10 of 10; P = 0.011). qCTV is a reliable means of quantifying ventricular volume and hydrocephalus. This technique offers a new tool for monitoring neurosurgical patients for hydrocephalus, and may be beneficial for use in future research studies, as well as in the routine care of patients with hydrocephalus. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Daryanani, Aditya; Dangi, Shusil; Ben-Zikri, Yehuda Kfir; Linte, Cristian A.
2016-03-01
Magnetic Resonance Imaging (MRI) is a standard-of-care imaging modality for cardiac function assessment and guidance of cardiac interventions thanks to its high image quality and lack of exposure to ionizing radiation. Cardiac health parameters such as left ventricular volume, ejection fraction, myocardial mass, thickness, and strain can be assessed by segmenting the heart from cardiac MRI images. Furthermore, the segmented pre-operative anatomical heart models can be used to precisely identify regions of interest to be treated during minimally invasive therapy. Hence, the use of accurate and computationally efficient segmentation techniques is critical, especially for intra-procedural guidance applications that rely on the peri-operative segmentation of subject-specific datasets without delaying the procedure workflow. Atlas-based segmentation incorporates prior knowledge of the anatomy of interest from expertly annotated image datasets. Typically, the ground truth atlas label is propagated to a test image using a combination of global and local registration. The high computational cost of non-rigid registration motivated us to obtain an initial segmentation using global transformations based on an atlas of the left ventricle from a population of patient MRI images and refine it using well developed technique based on graph cuts. Here we quantitatively compare the segmentations obtained from the global and global plus local atlases and refined using graph cut-based techniques with the expert segmentations according to several similarity metrics, including Dice correlation coefficient, Jaccard coefficient, Hausdorff distance, and Mean absolute distance error.
Radionuclide evaluation of left ventricular function with nonimaging probes.
Wexler, J P; Blaufox, M D
1979-10-01
Portable nonimaging probes have been developed that can evaluate left ventricular function using radionuclide techniques. Two modes of data acquisition are possible with these probe systems, first-pass and gated. Precordial radiocardiograms obtained after a bolus injection can be used to determine cardiac output, pulmonary transit time, pulmonary blood volume, left ventricle ejection fraction, and left-to-right shunts. Gated techniques can be used to determine left ventricular ejection fraction and sytolic time intervals. Probe-determined indices of left ventricular function agree excellently with comparable measurements determined by conventional camera-computer methods as well as by invasive techniques. These have begun to be used in a preliminary manner in a variety of clinical problems associated with left ventricular dysfunction. This review discusses the types of probe systems available, the methods used in positioning them, and details the specifics of their data acquisition and processing capacity. The major criticisms of probe methods are that they are nonimaging and that they measure global rather than regional left ventricular function. In spite of these criticisms, probe systems, because of their portability, high sensitivity, and relatively low cost are useful supplements to conventional camera-computer systems for the measurement of parameters of left ventricular performance using radionuclide techniques.
Khan, Fakhar Z; Virdee, Mumohan S; Palmer, Christopher R; Pugh, Peter J; O'Halloran, Denis; Elsik, Maros; Read, Philip A; Begley, David; Fynn, Simon P; Dutka, David P
2012-04-24
This study sought to assess the impact of targeted left ventricular (LV) lead placement on outcomes of cardiac resynchronization therapy (CRT). Placement of the LV lead to the latest sites of contraction and away from the scar confers the best response to CRT. We conducted a randomized, controlled trial to compare a targeted approach to LV lead placement with usual care. A total of 220 patients scheduled for CRT underwent baseline echocardiographic speckle-tracking 2-dimensional radial strain imaging and were then randomized 1:1 into 2 groups. In group 1 (TARGET [Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy]), the LV lead was positioned at the latest site of peak contraction with an amplitude of >10% to signify freedom from scar. In group 2 (control) patients underwent standard unguided CRT. Patients were classified by the relationship of the LV lead to the optimal site as concordant (at optimal site), adjacent (within 1 segment), or remote (≥2 segments away). The primary endpoint was a ≥15% reduction in LV end-systolic volume at 6 months. Secondary endpoints were clinical response (≥1 improvement in New York Heart Association functional class), all-cause mortality, and combined all-cause mortality and heart failure-related hospitalization. The groups were balanced at randomization. In the TARGET group, there was a greater proportion of responders at 6 months (70% vs. 55%, p = 0.031), giving an absolute difference in the primary endpoint of 15% (95% confidence interval: 2% to 28%). Compared with controls, TARGET patients had a higher clinical response (83% vs. 65%, p = 0.003) and lower rates of the combined endpoint (log-rank test, p = 0.031). Compared with standard CRT treatment, the use of speckle-tracking echocardiography to the target LV lead placement yields significantly improved response and clinical status and lower rates of combined death and heart failure-related hospitalization. (Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy [TARGET] study); ISRCTN19717943). Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Hansky, Bert; Vogt, Juergen; Gueldner, Holger; Schulte-Eistrup, Sebastian; Lamp, Barbara; Heintze, Johannes; Horstkotte, Dieter; Koerfer, Reiner
2007-01-01
Securing transvenous left ventricular (LV) pacing leads without an active fixation mechanism in proximal coronary vein (CV) segments is usually challenging and frequently impossible. We investigated how active fixation leads can be safely implanted in this location, how to avoid perforating the free wall of the CV, and how to recognize and respond to perforations. In five patients with no alternative to LV pacing from proximal CV segments, 4 Fr SelectSecure (Medtronic, Minneapolis, MN, USA) leads, which have a fixed helix, were implanted through a modified 6 Fr guide catheter with a pre-shaped tip (Launcher, Medtronic). Active fixation leads were successfully implanted in proximal CVs in five patients. There were no complications. Acute and chronic pacing thresholds were comparable to those of conventional CV leads. The pre-shaped guide catheter tip remains in close proximity to the myocardial aspect of the CV, directing the lead helix toward a safe implantation site. If only proximal CV pacing sites are available, 4 Fr SelectSecure leads can be safely implanted through a modified Launcher guide catheter, avoiding more invasive implantation techniques. Other than venous stenting or implantation of leads with retractable tines, SelectSecure leads are expected to remain extractable.
Dijkman, B; Wellens, H J
2000-12-01
Performance of dual chamber implantable cardioverter defibrillator (ICD) systems has been judged based on functioning of the ventricular tachycardia:supraventricular tachycardia (VT:SVT) discrimination criteria and DDD pacing. The purpose of this study was to evaluate the use of dual chamber diagnostics to improve the electrical and antiarrhythmic therapy of ventricular arrhythmias. Information about atrial and ventricular rhythm in relation to ventricular arrhythmia occurrence and therapy was evaluated in 724 spontaneous arrhythmia episodes detected and treated by three types of dual chamber ICDs in 41 patients with structural heart disease. Device programming was based on clinically documented and induced ventricular arrhythmias. In ambulatory patients, sinus tachycardia preceded ventricular arrhythmias more often than in the hospital during exercise testing. The incidence of these VTs could be reduced by increasing the dose of a beta-blocking agent in only two patients. In five patients in whom sinus tachycardia developed after onset of hemodynamic stable VT, propranolol was more effective than Class III antiarrhythmics combined with another beta-blocking agent with regard to the incidence of VT and pace termination. In all but three cases, atrial arrhythmias were present for a longer time before the onset of ventricular arrhythmias. During atrial arrhythmias, fast ventricular rates before the onset of ventricular rate were observed more often than RR irregularities and short-long RR sequences. Dual chamber diagnostics allowed proper interpretation of detection and therapy outcome in patients with different types of ventricular arrhythmia. The advantages of the dual chamber ICD system go further than avoiding the shortcomings of the single chamber system. Information from the atrial chamber allows better device programming and individualization of drug therapy for ventricular arrhythmia.
Cardinal, René; Ardell, Jeffrey L; Linderoth, Bengt; Vermeulen, Michel; Foreman, Robert D; Armour, J Andrew
2004-03-31
Spinal cord stimulation (SCS) represents an acceptable treatment modality for patients with chronic angina pectoris refractory to standard therapy, but its mechanism of action remains unclear. To develop an experimental paradigm to study this issue, ameroid (AM) constrictors were implanted around the left circumflex coronary artery (LCx) in canines. Six weeks later, unipolar electrograms were recorded from 191 sites in the LCx territory in the open-chest, anesthetized state under basal pacing at 150 beats/min. We investigated the effect of SCS on ST segment displacements induced in the collateral-dependent myocardium in response to two stressors: (i) transient bouts of rapid ventricular pacing (TRP: 240/min for 1 min) and (ii) angiotensin II administered to right atrial neurons via their coronary artery blood supply. ST segment responses to TRP consisted of ST segment elevation in central areas of the LCx territory and ST depression at more peripheral areas. Such responses were unchanged when TRP was applied under SCS. Shortening of repolarization intervals in the metabolically compromised myocardium in response to TRP was also unaffected by SCS. In contrast, ST segment responses to intracoronary angiotensin II, which consisted of increased ST elevation, were attenuated by SCS in 6/8 preparations. The modulator effects of SCS were greatest at sites at which the greatest responses to angiotensin II occurred in the absence of SCS. These data indicate that spinal cord stimulation may attenuate the deleterious effects that stressors exert on the myocardium with reduced coronary reserve, particularly stressors associated with chemical activation of the intrinsic cardiac nervous system. Copyright 2004 Elsevier B.V.
Biswas, Shankar K; Sarai, Masayoshi; Yamada, Akira; Toyama, Hiroshi; Motoyama, Sadako; Harigaya, Hiroto; Hara, Tomonori; Naruse, Hiroyuki; Hishida, Hitoshi; Ozaki, Yukio
2010-02-01
The evolution of the oxidative metabolism of (11)C acetate parallels the recovery of left ventricular(LV) contraction following acute myocardial infarction(AMI). This study was designed to unravel, for the first time, the impact of the global washout rate(WR) of (123)I-beta-methyl-p-iodophenylpentadecanoic acid (BMIPP) on the recovery of LV function followingAMI, as evidenced from conventional echocardiography.Twenty consecutive patients (age: 58 +/- 13 years; 16 males and 4 females) with ST-segment elevation myocardial infarction (STEMI) were enrolled and all of them underwent successful percutaneous coronary intervention (PCI). (123)I-BMIPP cardiac scintigraphy was performed at 7 +/- 3 days after admission. The WR was calculated from the polar map and the regional BMIPP defect score was calculated using a 17 segment model. Echocardiography was performed within 24 h of admission and at 3 months to record the ejection fraction (EF), the wall motion score index (WMSI), the ratio of the mitralinflow velocity to the early diastolic velocity (E/E0)and the myocardial performance index (MPI). The mean global WR of the BMIPP was 22.12 +/- 7.22%, and it was significantly correlated with the improvement of the WMSI (r = 0.61, P\\0.004). However,the relative changes of the EF, E/E0 and MPI were not correlated with the WR. The BMIPP defect score (18 +/- 10) was significantly correlated with the WMSI on admission (r = 0.74, P = 0.0002), but the defect score was not correlated with the relative changes of any of the echocardiographic parameters. We proved that the WR of the BMIPP is a promising indicator of improvement of the LV wall motion (WMSI) following ST-segment elevation myocardial infarction and successful reperfusion.
Avendi, M R; Kheradvar, Arash; Jafarkhani, Hamid
2016-05-01
Segmentation of the left ventricle (LV) from cardiac magnetic resonance imaging (MRI) datasets is an essential step for calculation of clinical indices such as ventricular volume and ejection fraction. In this work, we employ deep learning algorithms combined with deformable models to develop and evaluate a fully automatic LV segmentation tool from short-axis cardiac MRI datasets. The method employs deep learning algorithms to learn the segmentation task from the ground true data. Convolutional networks are employed to automatically detect the LV chamber in MRI dataset. Stacked autoencoders are used to infer the LV shape. The inferred shape is incorporated into deformable models to improve the accuracy and robustness of the segmentation. We validated our method using 45 cardiac MR datasets from the MICCAI 2009 LV segmentation challenge and showed that it outperforms the state-of-the art methods. Excellent agreement with the ground truth was achieved. Validation metrics, percentage of good contours, Dice metric, average perpendicular distance and conformity, were computed as 96.69%, 0.94, 1.81 mm and 0.86, versus those of 79.2-95.62%, 0.87-0.9, 1.76-2.97 mm and 0.67-0.78, obtained by other methods, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
Kaniewska, Malwina; Schuetz, Georg M; Willun, Steffen; Schlattmann, Peter; Dewey, Marc
2017-04-01
To compare the diagnostic accuracy of computed tomography (CT) in the assessment of global and regional left ventricular (LV) function with magnetic resonance imaging (MRI). MEDLINE, EMBASE and ISI Web of Science were systematically reviewed. Evaluation included: ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and left ventricular mass (LVM). Differences between modalities were analysed using limits of agreement (LoA). Publication bias was measured by Egger's regression test. Heterogeneity was evaluated using Cochran's Q test and Higgins I 2 statistic. In the presence of heterogeneity the DerSimonian-Laird method was used for estimation of heterogeneity variance. Fifty-three studies including 1,814 patients were identified. The mean difference between CT and MRI was -0.56 % (LoA, -11.6-10.5 %) for EF, 2.62 ml (-34.1-39.3 ml) for EDV and 1.61 ml (-22.4-25.7 ml) for ESV, 3.21 ml (-21.8-28.3 ml) for SV and 0.13 g (-28.2-28.4 g) for LVM. CT detected wall motion abnormalities on a per-segment basis with 90 % sensitivity and 97 % specificity. CT is accurate for assessing global LV function parameters but the limits of agreement versus MRI are moderately wide, while wall motion deficits are detected with high accuracy. • CT helps to assess patients with coronary artery disease (CAD). • MRI is the reference standard for evaluation of left ventricular function. • CT provides accurate assessment of global left ventricular function.
Atrioventricular junction (AVJ) motion tracking: a software tool with ITK/VTK/Qt.
Pengdong Xiao; Shuang Leng; Xiaodan Zhao; Hua Zou; Ru San Tan; Wong, Philip; Liang Zhong
2016-08-01
The quantitative measurement of the Atrioventricular Junction (AVJ) motion is an important index for ventricular functions of one cardiac cycle including systole and diastole. In this paper, a software tool that can conduct AVJ motion tracking from cardiovascular magnetic resonance (CMR) images is presented by using Insight Segmentation and Registration Toolkit (ITK), The Visualization Toolkit (VTK) and Qt. The software tool is written in C++ by using Visual Studio Community 2013 integrated development environment (IDE) containing both an editor and a Microsoft complier. The software package has been successfully implemented. From the software engineering practice, it is concluded that ITK, VTK, and Qt are very handy software systems to implement automatic image analysis functions for CMR images such as quantitative measure of motion by visual tracking.
Berg, Robert A; Sorrell, Vincent L; Kern, Karl B; Hilwig, Ronald W; Altbach, Maria I; Hayes, Melinda M; Bates, Kathryn A; Ewy, Gordon A
2005-03-08
Most out-of-hospital ventricular fibrillation (VF) is prolonged (>5 minutes), and defibrillation from prolonged VF typically results in asystole or pulseless electrical activity. Recent visual epicardial observations in an open-chest, open-pericardium model of swine VF indicate that blood flows from the high-pressure arterial system to the lower-pressure venous system during untreated VF, thereby overdistending the right ventricle and apparently decreasing left ventricular size. Therefore, inadequate left ventricular stroke volume after defibrillation from prolonged VF has been postulated as a major contributor to the development of pulseless rhythms. Ventricular dimensions were determined by MRI for 30 minutes of untreated VF in a closed-chest, closed-pericardium model in 6 swine. Within 1 minute of untreated VF, mean right ventricular volume increased by 29% but did not increase thereafter. During the first 5 minutes of untreated VF, mean left ventricular volume increased by 34%. Between 20 and 30 minutes of VF, stone heart occurred as manifested by dramatic thickening of the myocardium and concomitant substantial decreases in left ventricular volume. In this closed-chest swine model of VF, substantial right ventricular volume changes occurred early and did not result in smaller left ventricular volumes. The changes in ventricular volumes before the late development of stone heart do not explain why defibrillation from brief duration VF (<5 minutes) typically results in a pulsatile rhythm with return of spontaneous circulation, whereas defibrillation from prolonged VF (5 to 15 minutes) does not.
Furuta, Akihiro; Onishi, Hideo; Nakamoto, Kenta
This study aimed at developing the realistic striatal digital brain (SDB) phantom and to assess specific binding ratio (SBR) for ventricular effect in the 123 I-FP-CIT SPECT imaging. SDB phantom was constructed in to four segments (striatum, ventricle, brain parenchyma, and skull bone) using Percentile method and other image processing in the T2-weighted MR images. The reference image was converted into 128×128 matrixes to align MR images with SPECT images. The process image was reconstructed with projection data sets generated from reference images additive blurring, attenuation, scatter, and statically noise. The SDB phantom was evaluated to find the accuracy of calculated SBR and to find the effect of SBR with/without ventricular counts with the reference and process images. We developed and investigated the utility of the SDB phantom in the 123 I-FP-CIT SPECT clinical study. The true value of SBR was just marched to calculate SBR from reference and process images. The SBR was underestimated 58.0% with ventricular counts in reference image, however, was underestimated 162% with ventricular counts in process images. The SDB phantom provides an extremely convenient tool for discovering basic properties of 123 I-FP-CIT SPECT clinical study image. It was suggested that the SBR was susceptible to ventricle.
Kingma, J G; Linderoth, B; Ardell, J L; Armour, J A; DeJongste, M J; Foreman, R D
2001-08-13
Electrical stimulation of the dorsal aspect of the upper thoracic spinal cord is used increasingly to treat patients with angina pectoris refractory to conventional therapeutic strategies. The purpose of this study was to determine whether spinal cord stimulation (SCS) in dogs affects regional myocardial blood flow and left-ventricular (LV) function before and during transient obstruction of the left anterior descending coronary artery (LAD). In anesthetized dogs, regional myocardial blood flow distribution was determined using radiolabeled microspheres and left-ventricular function was measured by impedance-derived pressure-volume loops. SCS was accomplished by stimulating the dorsal T1-T2 segments of the spinal cord using epidural bipolar electrodes at 90% of motor threshold (MT) (50 Hz, 0.2-ms duration). Effects of 5-min SCS were assessed under basal conditions and during 4-min occlusion of the LAD. SCS alone evoked no change in regional myocardial blood flow or cardiovascular indices. Transient LAD occlusion significantly diminished blood flow within ischemic, but not in non-ischemic myocardial tissue. Left ventricular pressure-volume loops were shifted rightward during LAD occlusion. Cardiac indices were altered similarly during LAD occlusion and concurrent SCS. SCS does not influence the distribution of blood flow within the non-ischemic or ischemic myocardium. Nor does it modify LV pressure-volume dynamics in the anesthetized experimental preparation.
Buchan, Iris; Covvey, H. Dominic; Rakowski, Harry
1985-01-01
A program has been developed for left ventricular (LV) border tracking on ultrasound images. For each frame, forty border points at equally-spaced angles around the LV center are found gradually during three passes. Pass 1 uses adaptive thresholding to find the most obvious border points. Pass 2 then uses an artificial intelligence technique of finding possible border path segments, associating a score with each, and, from paths with superior scores, obtaining more of the border points. Pass 3 closes any remaining gaps by interpolation. The program tracks the LV border quite well in spite of dropout and interference from intracardiac structures, except during end-systole. Multi-level passes provide a very useful structure for border tracking, with increasingly slow but more sophisticated algorithms possible at higher levels for use when earlier passes recognise failure.
Atypical patterns of cardiac involvement in Fabry disease.
Coughlan, J J; Elkholy, K; O'Brien, J; Kiernan, T
2016-03-17
A 58-year-old woman was referred to our cardiology service with chest pain, exertional dyspnoea and palpitations on a background of known Fabry disease diagnosed with genetic testing in 1994. ECG showed sinus rhythm, shortened PR interval, widespread t wave inversion, q waves in the lateral leads and left ventricular hypertrophy (LVH). Coronary angiogram showed only mild atheroma. Transthoracic echocardiogram showed anterolateral LVH and reduced left ventricular cavity size in keeping with Fabry cardiomyopathy. Cardiac MRI demonstrated asymmetric hypertrophy with evidence of diffuse myocardial fibrosis in the maximally hypertrophied segments from base to apex with late gadolinium enhancement in the anterior and anteroseptal walls. This was quite an atypical appearance for Fabry cardiomyopathy. This case highlights the heterogeneity of patterns of cardiac involvement that may be associated with this rare X-linked lysosomal disorder. 2016 BMJ Publishing Group Ltd.
Mesalamine-induced myocarditis following diagnosis of Crohn's disease: a case report.
Galvão Braga, Carlos; Martins, Juliana; Arantes, Carina; Ramos, Vítor; Vieira, Catarina; Salgado, Alberto; Magalhães, Sónia; Correia, Adelino
2013-09-01
Mesalamine is a common treatment for Crohn's disease, and can be rarely associated with myocarditis through a mechanism of drug hypersensitivity. We present the case of a 19-year-old male who developed chest pain two weeks after beginning mesalamine therapy. The electrocardiogram showed slight ST-segment elevation with upward concavity in the inferolateral leads; blood tests demonstrated elevated troponin I and the echocardiogram revealed moderately depressed left ventricular systolic function with global hypocontractility. Cardiac magnetic resonance imaging confirmed the diagnosis of myocarditis, revealing multiple areas of subepicardial fibrosis. The onset of symptoms after mesalamine, and improvement of chest pain, cardiac biomarkers and left ventricular systolic function after discontinuing the drug, suggest that our patient suffered from a rare drug-hypersensitivity reaction to mesalamine. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Segmented Poincaré plot analysis for risk stratification in patients with dilated cardiomyopathy.
Voss, A; Fischer, C; Schroeder, R; Figulla, H R; Goernig, M
2010-01-01
The prognostic value of heart rate variability in patients with dilated cardiomyopathy (DCM) is limited and does not contribute to risk stratification although the dynamics of ventricular repolarization differs considerably between DCM patients and healthy subjects. Neither linear nor nonlinear methods of heart rate variability analysis could discriminate between patients at high and low risk for sudden cardiac death. The aim of this study was to analyze the suitability of the new developed segmented Poincaré plot analysis (SPPA) to enhance risk stratification in DCM. In contrast to the usual applied Poincaré plot analysis the SPPA retains nonlinear features from investigated beat-to-beat interval time series. Main features of SPPA are the rotation of cloud of points and their succeeded variability depended segmentation. Significant row and column probabilities were calculated from the segments and led to discrimination (up to p<0.005) between low and high risk in DCM patients. For the first time an index from Poincaré plot analysis of heart rate variability was able to contribute to risk stratification in patients suffering from DCM.
Gohean, Jeffrey R; George, Mitchell J; Pate, Thomas D; Kurusz, Mark; Longoria, Raul G; Smalling, Richard W
2013-01-01
The purpose of this investigation is to use a computational model to compare a synchronized valveless pulsatile left ventricular assist device with continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate the support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous pulsatile valveless dual-piston positive displacement pump. These results were compared with measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared with the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device.
Gohean, Jeffrey R.; George, Mitchell J.; Pate, Thomas D.; Kurusz, Mark; Longoria, Raul G.; Smalling, Richard W.
2012-01-01
The purpose of this investigation is to utilize a computational model to compare a synchronized valveless pulsatile left ventricular assist device to continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous, pulsatile, valveless, dual piston positive displacement pump. These results were compared to measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared to the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device. PMID:23438771
Nelson, O. Lynne; Rourke, Bryan C.
2013-01-01
SUMMARY Deep hibernators such as golden-mantled ground squirrels (Callospermophilus lateralis) have multiple challenges to cardiac function during low temperature torpor and subsequent arousals. As heart rates fall from over 300 beats min−1 to less than 10, chamber dilation and reduced cardiac output could lead to congestive myopathy. We performed echocardiography on a cohort of individuals prior to and after several months of hibernation. The left ventricular chamber exhibited eccentric and concentric hypertrophy during hibernation and thus calculated ventricular mass was ~30% greater. Ventricular ejection fraction was mildly reduced during hibernation but stroke volumes were greater due to the eccentric hypertrophy and dramatically increased diastolic filling volumes. Globally, the systolic phase in hibernation was ~9.5 times longer, and the diastolic phase was 28× longer. Left atrial ejection generally was not observed during hibernation. Atrial ejection returned weakly during early arousal. Strain echocardiography assessed the velocity and total movement distance of contraction and relaxation for regional ventricular segments in active and early arousal states. Myocardial systolic strain during early arousal was significantly greater than the active state, indicating greater total contractile movement. This mirrored the increased ventricular ejection fraction noted with early arousal. However, strain rates were slower during early arousal than during the active period, particularly systolic strain, which was 33% of active, compared with the rate of diastolic strain, which was 67% of active. As heart rate rose during the arousal period, myocardial velocities and strain rates also increased; this was matched closely by cardiac output. Curiously, though heart rates were only 26% of active heart rates during early arousal, the cardiac output was nearly 40% of the active state, suggesting an efficient pumping system. We further analyzed proportions of cardiac myosin heavy-chain (MyHC) isoforms in a separate cohort of squirrels over 5 months, including time points before hibernation, during hibernation and just prior to emergence. Hibernating individuals were maintained in both a 4°C cold room and a 20°C warm room. Measured by SDS-PAGE, relative percentages of cardiac MyHC alpha were increased during hibernation, at both hibernacula temperatures. A potential increase in contractile speed, and power, from more abundant MyHC alpha may aid force generation at low temperature and at low heart rates. Unlike many models of cardiomyopathies where the alpha isoform is replaced by the beta isoform in order to reduce oxygen consumption, ground squirrels demonstrate a potential cardioprotective mechanism to maintain cardiac output during torpor. PMID:24072796
NASA Astrophysics Data System (ADS)
Qin, Xulei; Cong, Zhibin; Fei, Baowei
2013-11-01
An automatic segmentation framework is proposed to segment the right ventricle (RV) in echocardiographic images. The method can automatically segment both epicardial and endocardial boundaries from a continuous echocardiography series by combining sparse matrix transform, a training model, and a localized region-based level set. First, the sparse matrix transform extracts main motion regions of the myocardium as eigen-images by analyzing the statistical information of the images. Second, an RV training model is registered to the eigen-images in order to locate the position of the RV. Third, the training model is adjusted and then serves as an optimized initialization for the segmentation of each image. Finally, based on the initializations, a localized, region-based level set algorithm is applied to segment both epicardial and endocardial boundaries in each echocardiograph. Three evaluation methods were used to validate the performance of the segmentation framework. The Dice coefficient measures the overall agreement between the manual and automatic segmentation. The absolute distance and the Hausdorff distance between the boundaries from manual and automatic segmentation were used to measure the accuracy of the segmentation. Ultrasound images of human subjects were used for validation. For the epicardial and endocardial boundaries, the Dice coefficients were 90.8 ± 1.7% and 87.3 ± 1.9%, the absolute distances were 2.0 ± 0.42 mm and 1.79 ± 0.45 mm, and the Hausdorff distances were 6.86 ± 1.71 mm and 7.02 ± 1.17 mm, respectively. The automatic segmentation method based on a sparse matrix transform and level set can provide a useful tool for quantitative cardiac imaging.
No effect of season on the electrocardiogram of long-eared bats (Nyctophilus gouldi) during torpor.
Currie, Shannon E
2018-04-05
Heterothermic animals regularly undergo profound alterations of cardiac function associated with torpor. These animals have specialised tissues capable of withstanding fluctuations in body temperature > 30 °C without adverse effects. In particular, the hearts of heterotherms are able to resist fibrillation and discontinuity of the cardiac conduction system common in homeotherms during hypothermia. To investigate the patterns of cardiac conduction in small insectivorous bats which enter torpor year round, I simultaneously measured ECG and subcutaneous temperature (T sub ) of 21 Nyctophilus gouldi (11 g) during torpor at a range of ambient temperatures (T a 1-28 °C). During torpor cardiac conduction slowed in a temperature dependent manner, primarily via prolongation along the atrioventricular pathway (PR interval). A close coupling of depolarisation and repolarisation was retained in torpid bats, with no isoelectric ST segment visible until animals reached T sub <6 °C. There was little change in ventricular repolarisation (JT interval) with decreasing T sub , or between rest and torpor at mild T a . Bats retained a more rapid rate of ventricular conduction and repolarisation during torpor relative to other hibernators. Throughout all recordings across seasons (> 2500 h), there was no difference in ECG morphology or heart rate during torpor, and no manifestations of significant conduction blocks or ventricular tachyarrhythmias were observed. My results demonstrate the capacity of bat hearts to withstand extreme fluctuations in rate and temperature throughout the year without detrimental arrhythmogenesis. I suggest that this conduction reserve may be related to flight and the daily extremes in metabolism experienced by these animals, and warrants further investigation of cardiac electrophysiology in other flying hibernators.
Syeda, Bonni; Höfer, Peter; Pichler, Philipp; Vertesich, Markus; Bergler-Klein, Jutta; Roedler, Susanne; Mahr, Stephane; Goliasch, Georg; Zuckermann, Andreas; Binder, Thomas
2011-07-01
Longitudinal strain determined by speckle tracking is a sensitive parameter to detect systolic left ventricular dysfunction. In this study, we assessed regional and global longitudinal strain values in long-term heart transplants and compared deformation indices with ejection fraction as determined by transthoracic echocardiography (TTE) and multislice computed tomographic coronary angiography (MSCTA). TTE and MSCTA were prospectively performed in 31 transplant patients (10.6 years post-transplantation) and in 42 control subjects. Grey-scale apical views were recorded for speckle tracking (EchoPAC 7.0, GE) of the 16 segments of the left ventricle. The presence of coronary artery disease (CAD) was assessed by MSCTA. Strain analysis was performed in 1168 segments [496 in transplant patients (42.5%), 672 in control subjects (57.7%)]. Global longitudinal peak systolic strain was significantly lower in the transplant recipients than in the healthy population (-13.9 ± 4.2 vs. -17.4 ± 5.8%, P< 0.01). This was still the case after exclusion of the nine transplant patients with CAD (-14.1 ± 4.4 vs. -17.4 ± 5.8%, P=0.03). Transplant patients exhibited significantly lower regional strain values in 9 of the 16 segments. Left ventricular ejection fraction (%) (MSCTA/Simpsons method) was 60.7 ± 10.1%/60.2 ± 6.7% in transplant recipients vs. 64.7 ± 6.4%/63.0 ± 6.2% in the healthy population, P=ns. Even though 'healthy' heart transplants without CAD exhibit normal ejection fraction, deformation indices are reduced in this population when compared with control subjects. Our findings suggests that strain analysis is more sensitive than assessment of ejection fraction for the detection of abnormalities of systolic function.
Ari, Mehmet Emre; Ekici, Filiz; Çetin, İbrahim İlker; Tavil, Emine Betül; Yaralı, Neşe; Işık, Pamir; Hazırolan, Tuncay; Tunç, Bahattin
2017-03-01
The purpose of this study is to determine early myocardial dysfunction in β-thalassemia major (BTM) patients. Where the myocardial dysfunction cannot be detected by conventional echocardiography, it could be detected by tissue Doppler imaging (TDI) or speckle tracking echocardiography (STE). In this study, we analyzed 60 individuals, 30 of whom were BTM patients and the other 30 of whom were the control group. T2* magnetic resonance imaging (MRI) was used to measure cardiac iron deposition. The myocardial functions were evaluated by conventional echocardiography, TDI and STE. When basal lateral left ventricular and basal septal wall TDI values were compared between the patient group and control group, only isovolumic contraction time values were significantly longer in the patients. The global circumferential strain was significantly lower in the patients. When evaluated as segmental, longitudinal strain values of basal inferoseptum and circumferential strain values of anteroseptum, anterior, and inferolateral segments were significantly lower in the patients. In the patients, global longitudinal and circumferential strains in the group who had pathological T2* values were significantly lower than the group who did not. In addition, circumferential strain values in anteroseptum, anterolateral, inferior, and inferoseptum segments were significantly lower in the patients with T2* values<20 ms than those with T2* values≥20 ms. Although T2* MRI is the most sensitive test detecting myocardial iron load, TDI and STE can be used for screening myocardial dysfunction. The abnormal strain values, especially circumferential, may be detected as the first finding of abnormal iron load and related to T2* values. © 2017, Wiley Periodicals, Inc.
Holbrook, M.; Coker, S. J.
1989-01-01
1. The aim of this study was to compare the effects of the non-selective phosphodiesterase (PDE) inhibitor, isobutylmethylxanthine (IBMX) and the selective PDE III inhibitor, milrinone, in a rabbit model of acute myocardial ischaemia. 2. Coronary artery occlusion caused changes in the ST-segment of the ECG and ectopic activity in all control rabbits. Ventricular fibrillation occurred in 10 out of 14 (71%) of these animals. Pretreatment with IBMX 100 micrograms kg-1 plus 10 micrograms kg-1 min-1, starting 10 min before coronary artery occlusion, reduced ischaemia-induced ST-segment changes and ventricular fibrillation occurred in only 10% of this group (n = 10). A similar dose of milrinone had no antiarrhythmic activity, whereas with a lower dose of milrinone, 30 micrograms kg-1 plus 3 micrograms kg-1 min-1 (n = 10), only 30% of rabbits fibrillated and ST-segment changes were attenuated. 3. Acute administration of both IBMX and milrinone reduced arterial blood pressure. With the higher dose of milrinone a significant effect was still present after 10 min of drug infusion. A greater hypotensive response to the higher dose of milrinone was observed in the rabbits which subsequently fibrillated during ischaemia. A marked tachycardia was also observed after administration of the higher dose of milrinone. 4. At the end of the experiment platelet aggregation was studied ex vivo. ADP-induced aggregation was reduced by pretreatment of the rabbits with milrinone but not IBMX. Both PDE inhibitors enhanced the ability of isoprenaline to inhibit ADP-induced platelet aggregation but milrinone was more effective, particularly at the higher dose.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:2478245
Jastrzębski, Jan; Kępka, Cezary; Kruk, Mariusz; Demkow, Marcin; Kalińczuk, Łukasz; Wolny, Rafał; Ciszewski, Michał; Michałowska, Ilona; Witkowski, Adam
2013-01-01
Introduction Heart rate irregularities are the major limitations of computed tomographic coronary angiography (CTCA) due to severe motion artifacts. Aim To evaluate the safety and efficacy of a lidocaine intravenous bolus in preserving good image quality by the transient suppression of premature ventricular contractions (PVC) during the CTCA scan. Material and methods The study group comprised 67 consecutive patients with sinus rhythm and numerous PVC scheduled for CTCA. Intravenous boluses of 25–50 mg lidocaine were given after calcium score assessment and immediately before CTCA. The control group comprised 67 patients with sinus rhythm without PVC matched according to the body mass index (BMI), age, sex, and calcium score. All coronary vessel segments were assessed for image quality and presence of significant stenosis. Results As compared with calcium score assessment, after administration of lidocaine and during the CTCA scan PVC were completely suppressed in 22 (40%), reduced in 10 (18%), unchanged in 18 (32%), and intensified in 5 (10%) patients. Overall, there were 32 (58%) patients with sinus rhythm during CTCA as compared with only 11 (20%) patients free from PVC during calcium score assessment (p < 0.001). Image quality in 871 coronary segments including both the study group and control patients was worse in patients with PVC (p < 0.0001). However, there was no statistically significant difference in the number of patients with at least one segment of non-diagnostic quality (6% vs. 12%, p = 0.36; respectively). Conclusions Single lidocaine bolus given prior to CTCA is safe, may temporarily eliminate or reduce the intensity of arrhythmia, and hence results in improved quality of CTCA in patients with numerous PVC. PMID:24570719
Pradel, Sarah; Brun, Stéphanie; Victor, Gérard; Pascal, Pierre; Fournier, Pauline; Ribes, David; Lavie-Badie, Yoan; Galinier, Michel; Carrié, Didier; Berry, Isabelle; Lairez, Olivier
2018-06-07
The purpose of the study was to describe the pattern of 99m Tc-labeled phosphate agents myocardial uptake by scintigraphy and explore its impact on left ventricular (LV) functions in transthyretin cardiac amyloidosis (TTR-CA). Fifty patients with TTR-CA underwent 99m Tc- hydroxymethylene-diphosphonate ( 99m Tc-HMDP) scintigraphy and echocardiography with measure of LV thickness, longitudinal strain (LS), systolic and diastolic functions. Cardiac retention by scintigraphy was assessed by visual scoring and the heart/whole body (H/WB) ratio was calculated by dividing counts in the heart by counts in late whole-body images. The mean population age was 79 ± 10 years. Mean H/WB ratio was 12 ± 7. Myocardial 99m Tc-HMDP uptake on segments 5, 6, 7, 8, 11, 12, 13, 14, 16, and 17 was correlated with H/WB ratio. Mean LVEF and global LS were 51 ± 10% and - 10 ± 3%, respectively. H/WB ratio was correlated with global LS (R = 0.408, P = .003), Ea (R = - 0.566, P < .001) and mean left ventricular wall thickness (R = 0.476, P < .001) but not with LVEF (R = - 0.109, P = .453). Segmental myocardial uptake was slightly correlated with segmental LS (R = 0.152, P < .001). H/WB ratio was not correlated with NT-proBNP levels (R = 0.219, P = .148) neither E/Ea ratio (R = 0.204, P = .184). These findings show the relationship between bone tracer myocardial uptake and LV functions in patients with TTR cardiac amyloidosis.
Electocardiographic findings in adult Nigerians with sickle cell anaemia.
Oguanobi, N I; Onwubere, B J C; Ike, S O; Anisiuba, B C; Ejim, E C; Ibegbulam, O G
2010-09-01
Cardiovascular system abnormalities are common causes of morbidity and mortality in sickle cell anaemia. The study aims at determining the pattern of electrocardiographic changes in adult Nigerian sickle cell anaemia patients. A descriptive cross sectional study was done on sixty sickle cell anaemia patients seen at the adult sickle cell clinic of University of Nigeria Teaching Hospital (UNTH) Enugu, and sixty age and sex matched normal controls. All the subjects had clinical evaluation as well as electrocardiographic examination. The mean heart rate, P-wave duration, P-wave dispersion, PR interval, QRS duration, QRS dispersion, QTc interval and QTc dispersion were significantly higher in the patients than in the control group. Electrocardiographic abnormalities identified by this study were: left ventricular hypertrophy (75%; 1.7%), left atrial enlargement (40%; 0%), biventricular hypertrophy (11%; 0), ST-segment elevation (10%; 0%) and increased P-wave and QTc dispersions. ST segment elevation was found more in patients with moderate and severe anaemia (P= 0.02, Spearman correlation r= 0.342; P= 0.007), Sickle cell anaemia is associated with significant electrocardiographic abnormalities. Further prospective studies are recommended to evaluate the prognostic significance of the electrocardiographic intervals dispersion on the long term disease outcome in sickle cell anaemia.
Meng, Juan; Lu, Yuewu; Dong, Xin; Liu, Hongyan
2014-04-08
To observe the long-term effects of hydroxychloroquine treatment on blood lipids and left ventricular function of systemic lupus erythematosus (SLE) patients. A total of 72 SLE patients were randomly divided into 2 groups of hydroxychloroquine treatment (n = 36) and non-hydroxychloroquine (n = 36). The serum level of lipids, left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), interventricular septum thickness (IVST), left ventricular posterior wall thickness (LVPWT), fractional shortening rate (FS), left ventricular ejection fraction (LVEF) and E/A ratio were measured before, 6 month, 12 month and 2 years after treatment. After long-term use of hydroxychloroquine, there were statistically differences in the levels of total cholesterol (TC), triglyceride (TG), low-density lipoprotein (LDL) and high-density lipoprotein (HDL). And LVEDD, LVWPT and E/A were statistically different (P < 0.05) before and after hydroxychloroquine dosing. The long-term use of hydroxychloroquine may improve lipid metabolism and left ventricular function in SLE patients.
Moon, James C C; Sachdev, Bhavesh; Elkington, Andrew G; McKenna, William J; Mehta, Atul; Pennell, Dudley J; Leed, Philip J; Elliott, Perry M
2003-12-01
Anderson-Fabry Disease (AFD), an X-linked disorder of sphingolipid metabolism, is a cause of idiopathic left ventricular hypertrophy but the mechanism of hypertrophy is poorly understood. Gadolinium enhanced cardiovascular magnetic resonance can detect focal myocardial fibrosis. We hypothesised that hyperenhancement would be present in AFD. Eighteen males (mean 43+/-14 years) and eight female heterozygotes (mean 48+/-12 years) with AFD underwent cine and late gadolinium cardiovascular magnetic resonance. Nine male (50%) had myocardial hyperenhancement ranging from 3.4% to 20.6% (mean 7.7+/-5.7%) of total myocardium; in males, percentage hyperenhancement related to LV mass index (r=0.78, P=0.0002) but not to ejection fraction or left ventricular volumes. Lesser hyperenhancement was also found in four (50%) heterozygous females (mean 4.6%). In 12 (92%) patients with abnormal gadolinium uptake, hyperenhancement occurred in the basal infero-lateral wall where, unlike myocardial infarction, it was not sub-endocardial. In two male patients with severe LVH (left ventricular hypertrophy) and systolic impairment there was additional hyperenhancement in other myocardial segments. These observations suggests that myocardial fibrosis occurs in AFD and may contribute to the hypertrophy and the natural history of the disease.
Satoh, Hiroshi; Sano, Makoto; Suwa, Kenichiro; Saitoh, Takeji; Nobuhara, Mamoru; Saotome, Masao; Urushida, Tsuyoshi; Katoh, Hideki; Hayashi, Hideharu
2014-07-26
The recent development of cardiac magnetic resonance (CMR) techniques has allowed detailed analyses of cardiac function and tissue characterization with high spatial resolution. We review characteristic CMR features in ischemic and non-ischemic cardiomyopathies (ICM and NICM), especially in terms of the location and distribution of late gadolinium enhancement (LGE). CMR in ICM shows segmental wall motion abnormalities or wall thinning in a particular coronary arterial territory, and the subendocardial or transmural LGE. LGE in NICM generally does not correspond to any particular coronary artery distribution and is located mostly in the mid-wall to subepicardial layer. The analysis of LGE distribution is valuable to differentiate NICM with diffusely impaired systolic function, including dilated cardiomyopathy, end-stage hypertrophic cardiomyopathy (HCM), cardiac sarcoidosis, and myocarditis, and those with diffuse left ventricular (LV) hypertrophy including HCM, cardiac amyloidosis and Anderson-Fabry disease. A transient low signal intensity LGE in regions of severe LV dysfunction is a particular feature of stress cardiomyopathy. In arrhythmogenic right ventricular cardiomyopathy/dysplasia, an enhancement of right ventricular (RV) wall with functional and morphological changes of RV becomes apparent. Finally, the analyses of LGE distribution have potentials to predict cardiac outcomes and response to treatments.
Kosmidou, Ioanna; Embacher, Monica; McAndrew, Thomas; Dizon, José M; Mehran, Roxana; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W
2017-11-15
The prevalence and impact of early ventricular arrhythmias (ventricular tachycardia [VT]/ventricular fibrillation [VF]) occurring before mechanical revascularization for acute ST segment elevation myocardial infarction (STEMI) treated with percutaneous coronary intervention are poorly understood. We sought to investigate the association between early VT/VF and long-term clinical outcomes using data from the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction trial. Among 3,602 patients with STEMI, 108 patients (3.0%) had early VT/VF. Baseline clinical characteristics were similar in patients with versus without early VT/VF. Patients with early VT/VF had shorter symptom-to-balloon times and lower left ventricular ejection fraction and underwent more frequent thrombectomy compared with patients without early VT/VF. Adjusted 3-year rates of all-cause death (15.7% vs 6.5%; adjusted hazard ratio 2.62, 95% confidence interval 1.48 to 4.61, p <0.001) and stent thrombosis (13.7% vs 5.7%; adjusted hazard ratio 2.74, 95% confidence interval 1.52 to 4.93, p <0.001) were significantly higher in patients with early VT/VF compared with patients without early VT/VF. In conclusion, in the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction trial, VT/VF occurring before coronary angiography and revascularization in patients with STEMI was strongly associated with increased 3-year rates of death and stent thrombosis. Further investigation into the mechanisms underlying the increased risk of early stent thrombosis in patients with early VT/VF is required. Copyright © 2017 Elsevier Inc. All rights reserved.
Kutty, Shelby; Olson, Joan; Danford, Christopher J; Sandene, Erin K; Xie, Feng; Fletcher, Scott E; Erickson, Christopher C; Kugler, John D; Danford, David A; Porter, Thomas R
2012-06-01
We sought to evaluate the efficacy of ultrasound contrast (UC) and low mechanical index real-time perfusion (RTP) in the haemodynamic and anatomic assessment of repaired congenital heart disease (CHD) at rest and during supine bicycle stress echocardiography (BSE). Patients with CHD (n = 51, median age 21.5 years) were prospectively studied. All had compromised image quality, 20 (39%) had arrhythmias, and 10 (20%) had pacemakers. RTP was performed at rest and during BSE using Definity and Contrast Pulse Sequencing, with assessment of Doppler pressure gradients. Diagnoses included tetralogy of Fallot (n = 27), transposition of the great arteries (TGA) atrial switch (n = 10), TGA arterial switch (n = 2), aortic valve disease (n = 4), Fontan (n = 4), and Kawasaki disease (n = 4). UC with RTP improved endocardial border definition, with increased number of left ventricular (LV) and right ventricular (RV) segments visualized at rest (P < 0.0001) and during stress. LV ejection fraction (EF) and RV fractional area change (FAC) were measurable at rest and peak stress, RV FAC correlating closely with same-day magnetic resonance EFs (r = 0.72; P < 0.001). UC enhanced Doppler signals, enabling subpulmonary ventricular systolic pressure measurements at rest and stress. In six patients, marked elevations of subpulmonary ventricular systolic pressure were detected with UC during BSE, and quantifiable ventricular dysfunction. No adverse events occurred, other than transient low back pain in one patient. UC at rest and with supine BSE enables safe and comprehensive assessment of anatomy, haemodynamics, and biventricular functional and perfusion reserve in adolescents and young adults with surgically modified CHD.
Cameli, M; Bernazzali, S; Lisi, M; Tsioulpas, C; Croccia, M G; Lisi, G; Maccherini, M; Mondillo, S
2012-09-01
Right ventricular (RV) systolic function has a critical role in determining the clinical outcome and the success of using left ventricular assist devices in patients with refractory heart failure. RV deformation analysis by speckle tracking echocardiography (STE) has recently allowed the analysis of RV longitudinal function. Using cardiac catheterization as the reference standard, this study aimed to explore the correlation between RV longitudinal function by STE and RV stroke work index (RVSWI) among patients referred for cardiac transplantation. Right heart catheterization and transthoracic echo-Doppler were simultaneously performed in 47 patients referred for cardiac transplant assessment due to refractory heart failure (ejection fraction 25.1 ± 4.5%). Thermodilution RV stroke volume and invasive pulmonary pressures were used to obtain RVSWI. RV longitudinal strain (RVLS) by STE was assessed averaging RV free-wall segments (free-wall RVLS). We also calculated. Tricuspid S' and tricuspid annular plane systolic excursion (TAPSE). No significant correlation was observed for TAPSE on tricuspid S' with RV stroke volume (r = 0.14 and r = 0.06, respectively). A close negative correlation between free-wall RVLS and RVSWI was found (r = -0.82; P < .0001). Furthermore, free-wall RVLS showed the highest diagnostic accuracy (area under the curve of 0.90) with good sensitivity and specificity of 95% and 91%, respectively, to predict depressed RVSWI using a cutoff value less than -11.8%. Among patients referred for heart transplantation, TAPSE and tricuspid S' did not correlate with invasively obtained RVSWI. RV longitudinal deformation analysis by STE correlated with RVSWI, providing a better estimate of RV systolic performance. Copyright © 2012 Elsevier Inc. All rights reserved.
Kerckhoffs, Roy C. P.; Neal, Maxwell L.; Gu, Quan; Bassingthwaighte, James B.; Omens, Jeff H.; McCulloch, Andrew D.
2010-01-01
In this study we present a novel, robust method to couple finite element (FE) models of cardiac mechanics to systems models of the circulation (CIRC), independent of cardiac phase. For each time step through a cardiac cycle, left and right ventricular pressures were calculated using ventricular compliances from the FE and CIRC models. These pressures served as boundary conditions in the FE and CIRC models. In succeeding steps, pressures were updated to minimize cavity volume error (FE minus CIRC volume) using Newton iterations. Coupling was achieved when a predefined criterion for the volume error was satisfied. Initial conditions for the multi-scale model were obtained by replacing the FE model with a varying elastance model, which takes into account direct ventricular interactions. Applying the coupling, a novel multi-scale model of the canine cardiovascular system was developed. Global hemodynamics and regional mechanics were calculated for multiple beats in two separate simulations with a left ventricular ischemic region and pulmonary artery constriction, respectively. After the interventions, global hemodynamics changed due to direct and indirect ventricular interactions, in agreement with previously published experimental results. The coupling method allows for simulations of multiple cardiac cycles for normal and pathophysiology, encompassing levels from cell to system. PMID:17111210
Specialized impulse conduction pathway in the alligator heart
Crossley, Dane A; Conner, Justin; Mohan, Rajiv A; van Duijvenboden, Karel; Postma, Alex V; Gloschat, Christopher R; Elsey, Ruth M; Sedmera, David; Efimov, Igor R
2018-01-01
Mammals and birds have a specialized cardiac atrioventricular conduction system enabling rapid activation of both ventricles. This system may have evolved together with high heart rates to support their endothermic state (warm-bloodedness) and is seemingly lacking in ectothermic vertebrates from which first mammals then birds independently evolved. Here, we studied the conduction system in crocodiles (Alligator mississippiensis), the only ectothermic vertebrates with a full ventricular septum. We identified homologues of mammalian conduction system markers (Tbx3-Tbx5, Scn5a, Gja5, Nppa-Nppb) and show the presence of a functional atrioventricular bundle. The ventricular Purkinje network, however, was absent and slow ventricular conduction relied on trabecular myocardium, as it does in other ectothermic vertebrates. We propose the evolution of the atrioventricular bundle followed full ventricular septum formation prior to the development of high heart rates and endothermy. In contrast, the evolution of the ventricular Purkinje network is strongly associated with high heart rates and endothermy. PMID:29565246
Lemarié, Jérémie; Huttin, Olivier; Girerd, Nicolas; Mandry, Damien; Juillière, Yves; Moulin, Frédéric; Lemoine, Simon; Beaumont, Marine; Marie, Pierre-Yves; Selton-Suty, Christine
2015-07-01
Right ventricular (RV) dysfunction after acute myocardial infarction (AMI) is frequent and associated with poor prognosis. The complex anatomy of the right ventricle makes its echocardiographic assessment challenging. Quantification of RV deformation by speckle-tracking echocardiography is a widely available and reproducible technique that readily provides an integrated analysis of all segments of the right ventricle. The aim of this study was to investigate the accuracy of conventional echocardiographic parameters and speckle-tracking echocardiographic strain parameters in assessing RV function after AMI, in comparison with cardiac magnetic resonance imaging (CMR). A total of 135 patients admitted for AMI (73 anterior, 62 inferior) were prospectively studied. Right ventricular function was assessed by echocardiography and CMR within 2 to 4 days of hospital admission. Right ventricular dysfunction was defined as CMR RV ejection fraction < 50%. Right ventricular global peak longitudinal systolic strain (GLPSS) was calculated by averaging the strain values of the septal, lateral, and inferior walls. Right ventricular dysfunction was documented in 20 patients. Right ventricular GLPSS was the best echographic correlate of CMR RV ejection fraction (r = -0.459, P < .0001) and possessed good diagnostic value for RV dysfunction (area under the receiver operating characteristic curve [AUROC], 0.724; 95% CI, 0.590-0.857), which was comparable with that of RV fractional area change (AUROC, 0.756; 95% CI, 0.647-0.866). In patients with inferior myocardial infarctions, the AUROCs for RV GLPSS (0.822) and inferolateral strain (0.877) were greater than that observed for RV fractional area change (0.760) Other conventional echocardiographic parameters performed poorly (all AUROCs < 0.700). After AMI, RV GLPSS is the best correlate of CMR RV ejection fraction. In patients with inferior AMIs, RV GLPSS displays even higher diagnostic value than conventional echocardiographic parameters. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Cuberas-Borrós, Gemma; Pineda, Victor; Aguadé-Bruix, Santiago; Romero-Farina, Guillermo; Pizzi, M Nazarena; de León, Gustavo; Castell-Conesa, Joan; García-Dorado, David; Candell-Riera, Jaume
2013-09-01
The aim of this study was to compare magnetic resonance and gated-SPECT myocardial perfusion imaging in patients with chronic myocardial infarction. Magnetic resonance imaging and gated-SPECT were performed in 104 patients (mean age, 61 [12] years; 87.5% male) with a previous infarction. Left ventricular volumes and ejection fraction and classic late gadolinium enhancement viability criteria (<75% transmurality) were correlated with those of gated-SPECT (uptake >50%) in the 17 segments of the left ventricle. Motion, thickening, and ischemia on SPECT were analyzed in segments showing nonviable tissue or equivocal enhancement features (50%-75% transmurality). A good correlation was observed between the 2 techniques for volumes, ejection fraction (P<.05), and estimated necrotic mass (P<.01). In total, 82 of 264 segments (31%) with >75% enhancement had >50% single SPECT uptake. Of the 106 equivocal segments on magnetic resonance imaging, 68 (64%) had >50% uptake, 41 (38.7%) had normal motion, 46 (43.4%) had normal thickening, and 17 (16%) had ischemic criteria on SPECT. A third of nonviable segments on magnetic resonance imaging showed >50% uptake on SPECT. Gated-SPECT can be useful in the analysis of motion, thickening, and ischemic criteria in segments with questionable viability on magnetic resonance imaging. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
A semi-automatic method for left ventricle volume estimate: an in vivo validation study
NASA Technical Reports Server (NTRS)
Corsi, C.; Lamberti, C.; Sarti, A.; Saracino, G.; Shiota, T.; Thomas, J. D.
2001-01-01
This study aims to the validation of the left ventricular (LV) volume estimates obtained by processing volumetric data utilizing a segmentation model based on level set technique. The validation has been performed by comparing real-time volumetric echo data (RT3DE) and magnetic resonance (MRI) data. A validation protocol has been defined. The validation protocol was applied to twenty-four estimates (range 61-467 ml) obtained from normal and pathologic subjects, which underwent both RT3DE and MRI. A statistical analysis was performed on each estimate and on clinical parameters as stroke volume (SV) and ejection fraction (EF). Assuming MRI estimates (x) as a reference, an excellent correlation was found with volume measured by utilizing the segmentation procedure (y) (y=0.89x + 13.78, r=0.98). The mean error on SV was 8 ml and the mean error on EF was 2%. This study demonstrated that the segmentation technique is reliably applicable on human hearts in clinical practice.
[Medical computer-aided detection method based on deep learning].
Tao, Pan; Fu, Zhongliang; Zhu, Kai; Wang, Lili
2018-03-01
This paper performs a comprehensive study on the computer-aided detection for the medical diagnosis with deep learning. Based on the region convolution neural network and the prior knowledge of target, this algorithm uses the region proposal network, the region of interest pooling strategy, introduces the multi-task loss function: classification loss, bounding box localization loss and object rotation loss, and optimizes it by end-to-end. For medical image it locates the target automatically, and provides the localization result for the next stage task of segmentation. For the detection of left ventricular in echocardiography, proposed additional landmarks such as mitral annulus, endocardial pad and apical position, were used to estimate the left ventricular posture effectively. In order to verify the robustness and effectiveness of the algorithm, the experimental data of ultrasonic and nuclear magnetic resonance images are selected. Experimental results show that the algorithm is fast, accurate and effective.
Left Ventricular Endocardium Tracking by Fusion of Biomechanical and Deformable Models
Gu, Jason
2014-01-01
This paper presents a framework for tracking left ventricular (LV) endocardium through 2D echocardiography image sequence. The framework is based on fusion of biomechanical (BM) model of the heart with the parametric deformable model. The BM model constitutive equation consists of passive and active strain energy functions. The deformations of the LV are obtained by solving the constitutive equations using ABAQUS FEM in each frame in the cardiac cycle. The strain energy functions are defined in two user subroutines for active and passive phases. Average fusion technique is used to fuse the BM and deformable model contours. Experimental results are conducted to verify the detected contours and the results are evaluated by comparing themto a created gold standard. The results and the evaluation proved that the framework has the tremendous potential to track and segment the LV through the whole cardiac cycle. PMID:24587814
Boonpeng, Hoh; Yusoff, Khalid
2013-03-01
The ultimate goal of human genetics is to understand the role of genome variation in elucidating human traits and diseases. Besides single nucleotide polymorphism (SNP), copy number variation (CNV), defined as gains or losses of a DNA segment larger than 1 kb, has recently emerged as an important tool in understanding heritable source of human genomic differences. It has been shown to contribute to genetic susceptibility of various common and complex diseases. Despite a handful of publications, its role in cardiovascular diseases remains largely unknown. Here, we deliberate on the currently available technologies for CNV detection. The possible utility and the potential roles of CNV in exploring the mechanisms of cardiac remodeling in hypertension will also be addressed. Finally, we discuss the challenges for investigations of CNV in cardiovascular diseases and its possible implications in diagnosis of hypertension-related left ventricular hypertrophy (LVH).
Matsuo, Shinro; Nakajima, Kenichi; Onoguchi, Masahisa; Wakabayash, Hiroshi; Okuda, Koichi; Kinuya, Seigo
2015-06-01
A novel multifocal collimator, IQ-SPECT (Siemens) consists of SMARTZOOM, cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 ((201)Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging. Forty patients (eight women, mean age of 75 years) who underwent myocardial perfusion imaging were included in the study. All patients underwent one-day protocol perfusion scan after an adenosine-stress test and at rest after administering (201)Tl and showed normal results. Acquisition was performed on a Symbia T6 equipped with a conventional dual-headed gamma camera system (Siemens ECAM) and with a multifocal SMARTZOOM collimator. Imaging was performed with a conventional system followed by IQ-SPECT/computed tomography (CT). Reconstruction was performed with or without X-ray CT-derived attenuation correction (AC). Two nuclear physicians blinded to clinical information interpreted all myocardial perfusion images. A semi-quantitative myocardial perfusion was analyzed by a 17-segment model with a 5-point visual scoring. The uptake of each segment was measured and left ventricular functions were analyzed by QPS software. IQ-SPECT provided good or excellent image quality. The quality of IQ-SPECT images without AC was similar to those of conventional LEHR study. Mid-inferior defect score (0.3 ± 0.5) in the conventional LEHR study was increased significantly in IQ-SPECT with AC (0 ± 0). IQ-SPECT with AC improved the mid-inferior decreased perfusion shown in conventional images. The apical tracer count in IQ-SPECT with AC was decreased compared to that in LEHR (0.1 ± 0.3 vs. 0.5 ± 0.7, p < 0.05). The left ventricular ejection fraction from IQ-SPECT was significantly higher than that from the LEHR collimator (p = 0.0009). The images of IQ-SPECT acquired in a short time are equivalent to that of conventional LEHR. The results indicated that the IQ-SPECT system with AC is capable of correcting inferior artifacts with high image quality.
Wilkinson, Molly; Kane, Tara; Wang, Rongpin; Takahashi, Emi
2017-12-01
The thalamus plays an important role in signal relays in the brain, with thalamocortical (TC) neuronal pathways linked to various sensory/cognitive functions. In this study, we aimed to see fetal and postnatal development of the thalamus including neuronal migration to the thalamus and the emergence/maturation of the TC pathways. Pathways from/to the thalami of human postmortem fetuses and in vivo subjects ranging from newborns to adults with no neurological histories were studied using high angular resolution diffusion MR imaging (HARDI) tractography. Pathways likely linked to neuronal migration from the ventricular zone and ganglionic eminence (GE) to the thalami were both successfully detected. Between the ventricular zone and thalami, more tractography pathways were found in anterior compared with posterior regions, which was well in agreement with postnatal observations that the anterior TC segment had more tract count and volume than the posterior segment. Three different pathways likely linked to neuronal migration from the GE to the thalami were detected. No hemispheric asymmetry of the TC pathways was quantitatively observed during development. These results suggest that HARDI tractography is useful to identify multiple differential neuronal migration pathways in human brains, and regional differences in brain development in fetal ages persisted in postnatal development. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
[Takotsubo syndrome. Transient left ventricular dyskinesia].
Pérez Pérez, F M; Sánchez Salado, J
2014-03-01
The Takotsubo syndrome, also called transient apical dyskinesia syndrome, was first described in Japan in the 1990s. It is a rare entity found in almost 1% of all patients with suspicion of acute coronary syndrome. It usually affects postmenopausal women with a few cardiovascular risk factors. It is characterized by angina-type chest pain, electrocardiographic changes, elevation of the enzymes of myocardial injury, absence of coronary obstruction on angiography, and a characteristic left ventricular anteroapical dyskinesia, which returns to normal within a few days. Severe emotional stress is the most common trigger for this syndrome. The aetiopathogenesis of this syndrome remains to be defined. This syndrome has been considered a clinical condition since 2001, when a series of 88 cases was published. It is a disease with a partially known mechanism, characterised by the morphology adopted by the left ventricle secondary to hypokinesis or dyskinesia of the apical segments, and hypercontractility of basal segments. Unlike acute coronary syndrome, patients with left ventricle dysfunction do not have atherothrombotic disease in the coronary arteries. In addition, the alterations described are reversible. Some clinical diagnostic criteria have been proposed, although they are still controversial, as well as in the complementary examinations required for diagnosis. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.
Ehara, Shoichi; Okuyama, Takuhiro; Shirai, Nobuyuki; Sugioka, Kenichi; Oe, Hiroki; Itoh, Toshihide; Matsuoka, Toshiyuki; Ikura, Yoshihiro; Ueda, Makiko; Naruko, Takahiko; Hozumi, Takeshi; Yoshiyama, Minoru
2009-08-01
Previous studies have shown a correlation between coronary artery cross-sectional diameter and left ventricular (LV) mass. However, no studies have examined the correlation between actual coronary artery volume (CAV) and LV mass. In the present study, measurements of CAV by 64-multislice computed tomography (MSCT) were validated and the relationship between CAV and LV mass was investigated. First, coronary artery phantoms consisting of syringes filled with solutions of contrast medium moving at simulated heart rates were scanned by 64-MSCT. Display window settings permitting accurate calculation of small volumes were optimized by evaluating volume-rendered images of the segmented contrast medium at different window settings. Next, 61 patients without significant coronary artery stenosis were scanned by 64-MSCT with the same protocol as for the phantoms. Coronary arteries were segmented on a workstation and the same window settings were applied to the volume-rendered images to calculate total CAV. Significant correlations between total CAV and LV mass (r=0.660, P<0.0001) were found, whereas an inverse relation was present between total CAV per 100 g of LV mass and LV mass. The novel concept of "CAV" for the characterization of coronary arteries may prove useful for future research, particularly on the causes of LV hypertrophy.
Mizuno, Ju; Mohri, Satoshi; Yokoyama, Takeshi; Otsuji, Mikiya; Arita, Hideko; Hanaoka, Kazuo
2017-02-01
Varying temperature affects cardiac systolic and diastolic function and the left ventricular (LV) pressure-time curve (PTC) waveform that includes information about LV inotropism and lusitropism. Our proposed half-logistic (h-L) time constants obtained by fitting using h-L functions for four segmental phases (Phases I-IV) in the isovolumic LV PTC are more useful indices for estimating LV inotropism and lusitropism during contraction and relaxation periods than the mono-exponential (m-E) time constants at normal temperature. In this study, we investigated whether the superiority of the goodness of h-L fits remained even at hypothermia and hyperthermia. Phases I-IV in the isovolumic LV PTCs in eight excised, cross-circulated canine hearts at 33, 36, and 38 °C were analyzed using h-L and m-E functions and the least-squares method. The h-L and m-E time constants for Phases I-IV significantly shortened with increasing temperature. Curve fitting using h-L functions was significantly better than that using m-E functions for Phases I-IV at all temperatures. Therefore, the superiority of the goodness of h-L fit vs. m-E fit remained at all temperatures. As LV inotropic and lusitropic indices, temperature-dependent h-L time constants could be more useful than m-E time constants for Phases I-IV.
Temporal analysis of regional wall motion from cine cardiac MRI
NASA Astrophysics Data System (ADS)
Ratib, Osman M.; Didier, Dominique; Chretien, Anne; Rosset, Antoine; Magnin, Isabelle E.; Ligier, Yves
1996-04-01
The purpose of this work is to develop and to evaluate an automatic analysis technique for quantitative assessment of cardiac function from cine MRI and to identify regional alterations in synchronicity based on Fourier analysis of ventricular wall motion (WM). A temporal analysis technique of left ventricular wall displacement was developed for quantitative analysis of temporal delays in wall motion and applied to gated cine 'dark blood' cardiac MRI. This imaging technique allows the user to saturate the blood both above and below the imaging slice simultaneously by using a specially designed rf presaturation pulse. The acquisition parameters are: TR equals 25 - 60 msec, TE equals 5 - 7 msec, 0 equals 25 degrees, slice thickness equals 10 mm, 16 to 32 frames/cycle. Automatic edge detection was used to outline the ventricular cavities on all frames of a cardiac cycle. Two different segmentation techniques were applied to all studies and lead to similar results. Further improvement in edge detection accuracy was achieved by temporal interpolation of individual contours on each image of the cardiac cycle. Radial analysis of the ventricular wall motion was then performed along 64 radii drawn from the center of the ventricular cavity. The first harmonic of the Fourier transform of each radial motion curve is calculated. The phase of the fundamental Fourier component is used as an index of synchrony (delay) of regional wall motion. Results are displayed in color-coded maps of regional alterations in the amplitude and synchrony of wall motion. The temporal delays measured from individual segments are evaluated through a histogram of phase distribution, where the width of the main peak is used as an index of overall synchrony of wall motion. The variability of this technique was validated in 10 normal volunteers and was used to identify regions with asynchronous WM in 15 patients with documented CAD. The standard deviation (SD) of phase distribution measured in short axis views was calculated and used to identify regions with asynchronous wall motion in patients with coronary artery disease. Results suggest that this technique is more sensitive than global functional parameters such as ejection fraction for the detection of ventricular dysfunction. Color coded parametric display offers a more convenient way for the identification and localization of regional wall motion asynchrony. Data obtained from endocardial wall motion analysis were not significantly different from wall thickening measurements. The innovative approach of evaluating the temporal behavior of regional wall motion anomalies is expected to provide clinically relevant data about subtle alteration that cannot be detected through simple analysis of the extent (amplitude) of wall motion or myocardial thickening. Temporal analysis of regional WM abnormality from cine MRI offers an innovative and promising means for objective quantitative evaluation of subtle regional abnormalities. Color coded parametric maps allowed a better identification and localization of regional WM asynchrony.
Student beats the teacher: deep neural networks for lateral ventricles segmentation in brain MR
NASA Astrophysics Data System (ADS)
Ghafoorian, Mohsen; Teuwen, Jonas; Manniesing, Rashindra; Leeuw, Frank-Erik d.; van Ginneken, Bram; Karssemeijer, Nico; Platel, Bram
2018-03-01
Ventricular volume and its progression are known to be linked to several brain diseases such as dementia and schizophrenia. Therefore accurate measurement of ventricle volume is vital for longitudinal studies on these disorders, making automated ventricle segmentation algorithms desirable. In the past few years, deep neural networks have shown to outperform the classical models in many imaging domains. However, the success of deep networks is dependent on manually labeled data sets, which are expensive to acquire especially for higher dimensional data in the medical domain. In this work, we show that deep neural networks can be trained on muchcheaper-to-acquire pseudo-labels (e.g., generated by other automated less accurate methods) and still produce more accurate segmentations compared to the quality of the labels. To show this, we use noisy segmentation labels generated by a conventional region growing algorithm to train a deep network for lateral ventricle segmentation. Then on a large manually annotated test set, we show that the network significantly outperforms the conventional region growing algorithm which was used to produce the training labels for the network. Our experiments report a Dice Similarity Coefficient (DSC) of 0.874 for the trained network compared to 0.754 for the conventional region growing algorithm (p < 0.001).
Congenital left ventricular aneurysms and diverticula: an entity in search of an identity
Ohlow, Marc-Alexander
2017-01-01
Congenital left ventricular aneurysm or diverticulum are rare cardiac malformations described in 809 cases since the first description in 1816, being associated with other cardiac, vascular or thoraco-abdominal abnormalities in about 70%. It appears to be a developmental anomaly, starting in the 4th embryonic week. In an experimental study, targeted knockdown of cardiac troponin T in the chick was performed at day 3, after the heart tube has formed. Morpholino treatment of gene TNNT2 at this stage led to the development of left ventricular diverticula (LVD) in the primitive left ventricular wall. Diagnosis of left ventricular aneurysms (LVA)/LVD can be made after exclusion of coronary artery disease, local or systemic inflammation or traumatic causes as well as cardiomyopathies. Clinically, most of LVA and LVD are asymptomatic or may cause systemic embolization, congestive heart failure, valvular regurgitation, ventricular wall rupture, ventricular tachycardia or sudden cardiac death. Diagnosis is established by imaging studies (echocardiography, magnetic resonance imaging or left ventricular angiography) visualizing the structural changes and accompanying abnormalities. Mode of treatment has to be individually tailored and depends on clinical presentation, accompanying abnormalities and possible complications, options include surgical resection (especially in symptomatic patients), anticoagulation after systemic embolization, radiofrequency ablation or implantation of an implantable cardioverter defibrillator (ICD) in case of symptomatic ventricular tachycardias, and occasionally combined with class I- or III-antiarrhythmic drugs. Cardiac death occurs usually in childhood, is significantly more frequent in LVA patients and caused by congestive heart failure in most of the cases, whereas patients diagnosed with LVD died more frequently from rupture of the LVD. PMID:29581714
Congenital left ventricular aneurysms and diverticula: an entity in search of an identity.
Ohlow, Marc-Alexander
2017-12-01
Congenital left ventricular aneurysm or diverticulum are rare cardiac malformations described in 809 cases since the first description in 1816, being associated with other cardiac, vascular or thoraco-abdominal abnormalities in about 70%. It appears to be a developmental anomaly, starting in the 4 th embryonic week. In an experimental study, targeted knockdown of cardiac troponin T in the chick was performed at day 3, after the heart tube has formed. Morpholino treatment of gene TNNT2 at this stage led to the development of left ventricular diverticula (LVD) in the primitive left ventricular wall. Diagnosis of left ventricular aneurysms (LVA)/LVD can be made after exclusion of coronary artery disease, local or systemic inflammation or traumatic causes as well as cardiomyopathies. Clinically, most of LVA and LVD are asymptomatic or may cause systemic embolization, congestive heart failure, valvular regurgitation, ventricular wall rupture, ventricular tachycardia or sudden cardiac death. Diagnosis is established by imaging studies (echocardiography, magnetic resonance imaging or left ventricular angiography) visualizing the structural changes and accompanying abnormalities. Mode of treatment has to be individually tailored and depends on clinical presentation, accompanying abnormalities and possible complications, options include surgical resection (especially in symptomatic patients), anticoagulation after systemic embolization, radiofrequency ablation or implantation of an implantable cardioverter defibrillator (ICD) in case of symptomatic ventricular tachycardias, and occasionally combined with class I- or III-antiarrhythmic drugs. Cardiac death occurs usually in childhood, is significantly more frequent in LVA patients and caused by congestive heart failure in most of the cases, whereas patients diagnosed with LVD died more frequently from rupture of the LVD.
Remote magnetic navigation to map and ablate left coronary cusp ventricular tachycardia.
Burkhardt, J David; Saliba, Walid I; Schweikert, Robert A; Cummings, Jennifer; Natale, Andrea
2006-10-01
Premature ventricular contractions (PVCs) and ventricular tachycardia may arise from the coronary cusps. Navigation, mapping, and ablation in the coronary cusps can be challenging. Remote magnetic navigation may offer an alternative to conventional manually operated catheters. We report a case of left coronary cusp ventricular tachycardia ablation using remote magnetic navigation. Right ventricular outflow tract and coronary cusp mapping, and ablation of the left coronary cusp using a remote magnetic navigation and three-dimensional (3-D) mapping system was performed in a 28-year-old male with frequent, symptomatic PVCs and ventricular tachycardia. Successful ablation of left coronary cusp ventricular tachycardia was performed using remote magnetic navigation. Remote magnetic navigation may be used to map and ablate PVCs and ventricular tachycardia originating from the coronary cusps.
Saito, Daiga; Nakanishi, Rine; Watanabe, Ippei; Yabe, Takayuki; Okubo, Ryo; Amano, Hideo; Toda, Mikihito; Ikeda, Takanori
2018-05-01
In patients with ST-segment elevation myocardial infarction (STEMI), it is unclear if combined assessment of left ventricular end-diastolic pressure (LVEDP) and left ventricular ejection fraction (LVEF) improves prediction of major adverse cardiac events (MACE). We analyzed data from 266 STEMI patients who underwent successful percutaneous coronary intervention and subsequent left ventriculography (LVG). Patients were divided into 4 groups, as follows: Group 1, LVEDP < 21 mmHg and LVEF ≥ 55%; Group 2, LVEDP < 21 mmHg and LVEF < 55%; Group 3, LVEDP ≥ 21 mmHg and LVEF ≥ 55%; and Group 4, LVEDP ≥ 21 mmHg and LVEF < 55%. Multivariate Cox proportional hazards analysis was used to determine if LVEDP and LVEF were associated with MACE (including cardiac death, non-fatal myocardial infarction, and heart failure requiring hospitalization). Change in LV parameters was assessed in the subset of 183 patients who underwent serial LVG (mean interval 6.3 ± 1.6 months). During a mean follow-up of 43 ± 31 months, 29 patients (10.9%) had a MACE. As compared to Group 1, MACE risk was significantly higher in Group 3 [hazard ratio (HR) 3.26; 95% confidence interval (CI) 1.05-10.0] and Group 4 (HR 3.99; 95% CI 1.44-11.0), but not in Group 2 (HR 0.46, 95% CI 0.54-3.96). In sub-analyses, LV end-systolic volume index after PCI was significantly higher in Group 4 than in the other groups and remained higher during follow-up. Combined LVEDP/LVEF assessment was useful in predicting MACE after successful PCI for STEMI patients and could facilitate risk stratification, as it predicts LV remodeling.
Planer, David; Mehran, Roxana; Witzenbichler, Bernhard; Guagliumi, Giulio; Peruga, Jan Z; Brodie, Bruce R; Dudek, Dariusz; Möckel, Martin; Reyes, Selene Leon; Stone, Gregg W
2011-10-15
Measurement of left ventricular end-diastolic pressure (LVEDP) is readily obtainable in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). However, the prognostic utility of LVEDP during primary PCI has never been studied. LVEDP was measured in 2,797 patients during primary PCI in the Harmonizing Outcomes with RevascularIZatiON and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial. Outcomes were assessed at 30 days and 2 years stratified by medians of LVEDP. Multivariable analysis was performed to determine whether LVEDP was an independent determinate of adverse outcomes. The median (interquartile range) for LVEDP was 18 mm Hg (12 to 24). For patients with LVEDP >18 mm Hg versus those with ≤18 mm Hg, hazard ratios (95% confidence intervals) for death and death or reinfarction at 30 days were 2.00 (1.20 to 3.33, p = 0.007) and 1.84 (1.24 to 2.73, p = 0.002), respectively, and at 2 years were 1.57 (1.12 to 2.21, p = 0.009) and 1.45 (1.14 to 1.85, p = 0.002), respectively. Patients in the highest quartile of LVEDP (≥24 mm Hg) were at the greatest risk of mortality. Only a weak correlation was present between LVEDP and left ventricular ejection fraction (LVEF; R(2) = 0.03, p <0.01). By multivariable analysis increased LVEDP was an independent predictor of death or reinfarction at 2 years (hazard ratio 1.20, 95% confidence interval 1.02 to 1.42, p = 0.03) even after adjustment for baseline LVEF. In conclusion, baseline increased LVEDP is an independent predictor of adverse outcomes in patients with STEMI undergoing primary PCI even after adjustment for baseline LVEF. Patients with LVEDP ≥24 mm Hg are at the greatest risk for early and late mortality. Copyright © 2011 Elsevier Inc. All rights reserved.
Spinelli, Letizia; Imbriaco, Massimo; Nappi, Carmela; Nicolai, Emanuele; Giugliano, Giuseppe; Ponsiglione, Andrea; Diomiaiuti, Tommaso Claudio; Riccio, Eleonora; Duro, Giovanni; Pisani, Antonio; Trimarco, Bruno; Cuocolo, Alberto
2018-04-01
Hybrid 18 F-fluorodeoxyglucose (FDG) positron emission tomography and magnetic resonance imaging may differentiate mature fibrosis or scar from fibrosis associated to active inflammation in patients with Anderson-Fabry disease, even in nonhypertrophic stage. This study was designed to compare the results of positron emission tomography and magnetic resonance cardiac imaging with those of speckle-tracking echocardiography in heterozygous Anderson-Fabry disease females. Twenty-four heterozygous females carrying α-galactosidase A mutation and without left ventricular hypertrophy underwent cardiac positron emission tomography and magnetic resonance using 18 F-FDG for glucose uptake and 2-dimensional strain echocardiography. 18 F-FDG myocardial uptake was quantified by measuring the coefficient of variation (COV) of the standardized uptake value using a 17-segment model. Focal 18 F-FDG uptake with COV >0.17 was detected in 13 patients, including 2 patients with late gadolinium enhancement at magnetic resonance. COV was 0.30±0.14 in patients with focal 18 F-FDG uptake and 0.12±0.03 in those without ( P <0.001). Strain echocardiography revealed worse global longitudinal systolic strain in patients with COV >0.17 compared with those with COV ≤0.17 (-18.5±2.7% versus -22.2±1.8%; P =0.024). For predicting COV >0.17, a global longitudinal strain >-19.8% had 77% sensitivity and 91% specificity and a value >2 dysfunctional segments 92% sensitivity and 100% specificity. In females carrying α-galactosidase A mutation, focal 18 F-FDG uptake represents an early sign of disease-related myocardial damage and is associated with impaired left ventricular longitudinal function. These findings support the hypothesis that inflammation plays an important role in glycosphingolipids storage disorders. © 2018 American Heart Association, Inc.
Wawrzyniak, Andrew J; Dilsizian, Vasken; Krantz, David S; Harris, Kristie M; Smith, Mark F; Shankovich, Anthony; Whittaker, Kerry S; Rodriguez, Gabriel A; Gottdiener, John; Li, Shuying; Kop, Willem; Gottlieb, Stephen S
2015-10-01
Mental stress can trigger myocardial ischemia, but the prevalence of mental stress-induced ischemia in congestive heart failure (CHF) patients is unknown. We characterized mental stress-induced and adenosine-induced changes in myocardial perfusion and neurohormonal activation in CHF patients with reduced left-ventricular function using SPECT to precisely quantify segment-level myocardial perfusion. Thirty-four coronary artery disease patients (mean age±SD, 62±10 y) with CHF longer than 3 mo and ejection fraction less than 40% underwent both adenosine and mental stress myocardial perfusion SPECT on consecutive days. Mental stress consisted of anger recall (anger-provoking speech) followed by subtraction of serial sevens. The presence and extent of myocardial ischemia was quantified using the conventional 17-segment model. Sixty-eight percent of patients had 1 ischemic segment or more during mental stress and 81% during adenosine. On segment-by-segment analysis, perfusion with mental stress and adenosine were highly correlated. No significant differences were found between any 2 time points for B-type natriuretic peptide, tumor necrosis factor-α, IL-1b, troponin, vascular endothelin growth factor, IL-17a, matrix metallopeptidase-9, or C-reactive protein. However, endothelin-1 and IL-6 increased, and IL-10 decreased, between the stressor and 30 min after stress. Left-ventricular end diastolic dimension was 179±65 mL at rest and increased to 217±71 after mental stress and 229±86 after adenosine (P<0.01 for both). Resting end systolic volume was 129±60 mL at rest and increased to 158±66 after mental stress (P<0.05) and 171±87 after adenosine (P<0.07), with no significant differences between adenosine and mental stress. Ejection fraction was 30±12 at baseline, 29±11 with mental stress, and 28±10 with adenosine (P=not significant). There was high concordance between ischemic perfusion defects induced by adenosine and mental stress, suggesting that mental stress is equivalent to pharmacologic stress in eliciting clinically significant myocardial perfusion defects in CHF patients. Cardiac dilatation suggests clinically important changes with both conditions. Psychosocial stressors during daily life may contribute to the ischemic burden of CHF patients with coronary artery disease. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Bulluck, Heerajnarain; Rosmini, Stefania; Abdel-Gadir, Amna; White, Steven K; Bhuva, Anish N; Treibel, Thomas A; Fontana, Marianna; Ramlall, Manish; Hamarneh, Ashraf; Sirker, Alex; Herrey, Anna S; Manisty, Charlotte; Yellon, Derek M; Kellman, Peter; Moon, James C; Hausenloy, Derek J
2016-10-01
The presence of intramyocardial hemorrhage (IMH) in ST-segment-elevation myocardial infarction patients reperfused by primary percutaneous coronary intervention has been associated with residual myocardial iron at follow-up, and its impact on adverse left ventricular (LV) remodeling is incompletely understood and is investigated here. Forty-eight ST-segment-elevation myocardial infarction patients underwent cardiovascular magnetic resonance at 4±2 days post primary percutaneous coronary intervention, of whom 40 had a follow-up scan at 5±2 months. Native T1, T2, and T2* maps were acquired. Eight out of 40 (20%) patients developed adverse LV remodeling. A subset of 28 patients had matching T2* maps, of which 15/28 patients (54%) had IMH. Eighteen of 28 (64%) patients had microvascular obstruction on the acute scan, of whom 15/18 (83%) patients had microvascular obstruction with IMH. On the follow-up scan, 13/15 patients (87%) had evidence of residual iron within the infarct zone. Patients with residual iron had higher T2 in the infarct zone surrounding the residual iron when compared with those without. In patients with adverse LV remodeling, T2 in the infarct zone surrounding the residual iron was also higher than in those without (60 [54-64] ms versus 53 [51-56] ms; P=0.025). Acute myocardial infarct size, extent of microvascular obstruction, and IMH correlated with the change in LV end-diastolic volume (Pearson's rho of 0.64, 0.59, and 0.66, respectively; P=0.18 and 0.62, respectively, for correlation coefficient comparison) and performed equally well on receiver operating characteristic curve for predicting adverse LV remodeling (area under the curve: 0.99, 0.94, and 0.95, respectively; P=0.19 for receiver operating characteristic curve comparison). The majority of ST-segment-elevation myocardial infarction patients with IMH had residual myocardial iron at follow-up. This was associated with persistently elevated T2 values in the surrounding infarct tissue and adverse LV remodeling. IMH and residual myocardial iron may be potential therapeutic targets for preventing adverse LV remodeling in reperfused ST-segment-elevation myocardial infarction patients. © 2016 The Authors.
NASA Astrophysics Data System (ADS)
Saris, Anne E. C. M.; Nillesen, Maartje M.; Lopata, Richard G. P.; de Korte, Chris L.
2013-03-01
Automated segmentation of 3D echocardiographic images in patients with congenital heart disease is challenging, because the boundary between blood and cardiac tissue is poorly defined in some regions. Cardiologists mentally incorporate movement of the heart, using temporal coherence of structures to resolve ambiguities. Therefore, we investigated the merit of temporal cross-correlation for automated segmentation over the entire cardiac cycle. Optimal settings for maximum cross-correlation (MCC) calculation, based on a 3D cross-correlation based displacement estimation algorithm, were determined to obtain the best contrast between blood and myocardial tissue over the entire cardiac cycle. Resulting envelope-based as well as RF-based MCC values were used as additional external force in a deformable model approach, to segment the left-ventricular cavity in entire systolic phase. MCC values were tested against, and combined with, adaptive filtered, demodulated RF-data. Segmentation results were compared with manually segmented volumes using a 3D Dice Similarity Index (3DSI). Results in 3D pediatric echocardiographic images sequences (n = 4) demonstrate that incorporation of temporal information improves segmentation. The use of MCC values, either alone or in combination with adaptive filtered, demodulated RF-data, resulted in an increase of the 3DSI in 75% of the cases (average 3DSI increase: 0.71 to 0.82). Results might be further improved by optimizing MCC-contrast locally, in regions with low blood-tissue contrast. Reducing underestimation of the endocardial volume due to MCC processing scheme (choice of window size) and consequential border-misalignment, could also lead to more accurate segmentations. Furthermore, increasing the frame rate will also increase MCC-contrast and thus improve segmentation.
Assessment of LVEF using a new 16-segment wall motion score in echocardiography.
Lebeau, Real; Serri, Karim; Lorenzo, Maria Di; Sauvé, Claude; Le, Van Hoai Viet; Soulières, Vicky; El-Rayes, Malak; Pagé, Maude; Zaïani, Chimène; Garot, Jérôme; Poulin, Frédéric
2018-06-01
Simpson biplane method and 3D by transthoracic echocardiography (TTE), radionuclide angiography (RNA) and cardiac magnetic resonance imaging (CMR) are the most accepted techniques for left ventricular ejection fraction (LVEF) assessment. Wall motion score index (WMSI) by TTE is an accepted complement. However, the conversion from WMSI to LVEF is obtained through a regression equation, which may limit its use. In this retrospective study, we aimed to validate a new method to derive LVEF from the wall motion score in 95 patients. The new score consisted of attributing a segmental EF to each LV segment based on the wall motion score and averaging all 16 segmental EF into a global LVEF. This segmental EF score was calculated on TTE in 95 patients, and RNA was used as the reference LVEF method. LVEF using the new segmental EF 15-40-65 score on TTE was compared to the reference methods using linear regression and Bland-Altman analyses. The median LVEF was 45% (interquartile range 32-53%; range from 15 to 65%). Our new segmental EF 15-40-65 score derived on TTE correlated strongly with RNA-LVEF ( r = 0.97). Overall, the new score resulted in good agreement of LVEF compared to RNA (mean bias 0.61%). The standard deviations (s.d.s) of the distributions of inter-method difference for the comparison of the new score with RNA were 6.2%, indicating good precision. LVEF assessment using segmental EF derived from the wall motion score applied to each of the 16 LV segments has excellent correlation and agreement with a reference method. © 2018 The authors.
NASA Technical Reports Server (NTRS)
Webb, J. A., Jr.
1974-01-01
The multipurpose ventricular actuating system is a pneumatic signal generating device that provides controlled driving pressures for actuating pulsatile blood pumps. Overall system capabilities, the timing circuitry, and calibration instruction are included.
Arterial Ventricular Uncoupling with Age and Disease and Recoupling with Exercise
Chantler, Paul D
2017-01-01
The deterioration in arterial and cardiac function with aging impairs arterial ventricular coupling, an important determinant of cardiovascular performance. However, exercise training improves arterial ventricular coupling especially during exercise during the age and disease process. This review examines the concept of arterial-ventricular coupling, and how age, and disease uncouples but exercise training recouples the heart and arterial system. PMID:28072585
MURESAN, Lucian; PETCU, Ana; MURESAN, Crina; RINZIS, Mirela; GUSETU, Gabriel; POP, Dana; ZDRENGHEA, Dumitru; REDNIC, Simona
2017-01-01
Background: In patients with systemic sclerosis, NT-proBNP is a useful diagnostic marker for pulmonary hypertension and ventricular dysfunction, with important prognostic significance. The aim of this study was to assess the relationship between the NT-proBNP levels and the presence and severity of ventricular arrhythmias in patients with scleroderma. Methods: Forty consecutive patients with a diagnostic of systemic sclerosis according to the EULAR criteria admitted at the Rheumatology Clinic of Cluj-Napoca, Romania, from Jan 2014 to Apr 2014 were enrolled. Patients underwent a 12-lead ECG and a 24-hour Holter ECG monitoring for ventricular arrhythmias evaluation. Blood sample testing (including NT-proBNP level measurements), echocardiography, spirometry, chest X-ray and, when considered appropriate, high-resolution chest CT were performed. Results: Sixty percent of patients (n=24) had abnormal NT-proBNP serum levels (>125 pg/ml) and 10 patients had >100 PVC/24 h. There was a statistically significant correlation between the NT-proBNP levels and the total number of premature ventricular contractions (PVC) (r=0.445, P=0.006), total number of isolated PVC (r=0,493, P=0.002), total number of ventricular couplets (r=0.379, P=0.021) and the number of PVC morphologies (r=0.501, P=0.002). The presence of an NT-proBNP serum level >287 pg/ml had a sensitivity of 55% and a specificity of 93% in predicting the presence of complex ventricular arrhythmias on 24-hour Holter ECG monitoring. Conclusion: NT-proBNP levels could become a useful ventricular arrhythmia marker for assessing the arrhythmic risk in patients with systemic sclerosis. PMID:28845401
Shi, Jie; Stonnington, Cynthia M; Thompson, Paul M; Chen, Kewei; Gutman, Boris; Reschke, Cole; Baxter, Leslie C; Reiman, Eric M; Caselli, Richard J; Wang, Yalin
2015-01-01
Mild Cognitive Impairment (MCI) is a transitional stage between normal aging and dementia and people with MCI are at high risk of progression to dementia. MCI is attracting increasing attention, as it offers an opportunity to target the disease process during an early symptomatic stage. Structural magnetic resonance imaging (MRI) measures have been the mainstay of Alzheimer's disease (AD) imaging research, however, ventricular morphometry analysis remains challenging because of its complicated topological structure. Here we describe a novel ventricular morphometry system based on the hyperbolic Ricci flow method and tensor-based morphometry (TBM) statistics. Unlike prior ventricular surface parameterization methods, hyperbolic conformal parameterization is angle-preserving and does not have any singularities. Our system generates a one-to-one diffeomorphic mapping between ventricular surfaces with consistent boundary matching conditions. The TBM statistics encode a great deal of surface deformation information that could be inaccessible or overlooked by other methods. We applied our system to the baseline MRI scans of a set of MCI subjects from the Alzheimer's Disease Neuroimaging Initiative (ADNI: 71 MCI converters vs. 62 MCI stable). Although the combined ventricular area and volume features did not differ between the two groups, our fine-grained surface analysis revealed significant differences in the ventricular regions close to the temporal lobe and posterior cingulate, structures that are affected early in AD. Significant correlations were also detected between ventricular morphometry, neuropsychological measures, and a previously described imaging index based on fluorodeoxyglucose positron emission tomography (FDG-PET) scans. This novel ventricular morphometry method may offer a new and more sensitive approach to study preclinical and early symptomatic stage AD. Copyright © 2014 Elsevier Inc. All rights reserved.
Gregori, Mario; Giammarioli, Benedetta; Tocci, Giuliano; Befani, Alberto; Ciavarella, Giuseppino Massimo; Ferrucci, Andrea; Paneni, Francesco
2015-12-01
Right ventricular dysfunction (RVD) is associated with poor cardiovascular outcome. The renin-angiotensin-aldosterone system is involved in alterations of the left ventricular geometry and function. Detrimental effects of the renin-angiotensin-aldosterone system on the right ventricular function are being postulated, but data supporting this assumption are still lacking. The aim of the study was to assess the impact of hyperreninemia, hyperaldosteronism or their combination on right ventricular function in hypertensive individuals. Plasma renin activity (PRA) and plasma aldosterone concentrations (PACs) were measured in 116 hypertensive patients, divided as follows: normal PRA and PAC (n = 38); high PRA and normal PAC (hypereninemia) (n = 26); normal PRA and high PAC (hyperaldosternism) (n = 27); high PRA and PAC (HRA) (n = 25). Echocardiographic evaluation of the left and right ventricles (RV), including tissue Doppler imaging, was performed. RVD was identified by tissue Doppler Imaging-derived Myocardial Performance Index, calculated with a multisegmental approach. Indices of the right ventricular structure and function, as well as the prevalence of RVD, were higher in hyperreninemia and hyperaldosternism groups as compared with the normal group, and a further increase was observed in the HRA patients. Regression models showed a similar risk of RVD in the hyperreninemia and hyperaldosternism patients, regardless of systemic and pulmonary pressure, as well as left ventricular dysfunction. Notably, patients with both hyperreninemia and hyperaldosternism exhibited the strongest association with RVD as compared with patients with only hyperreninemia or hyperaldosternism. Isolated hyperreninemia or hyperaldosternism determines a similar impairment of the right ventricular function, whereas their combination is further detrimental. Renin and aldosterone may represent early biomarkers of right ventricular dysfunction in hypertension.
Shi, Jie; Stonnington, Cynthia M.; Thompson, Paul M.; Chen, Kewei; Gutman, Boris; Reschke, Cole; Baxter, Leslie C.; Reiman, Eric M.; Caselli, Richard J.; Wang, Yalin
2014-01-01
Mild Cognitive Impairment (MCI) is a transitional stage between normal aging and dementia and people with MCI are at high risk of progression to dementia. MCI is attracting increasing attention, as it offers an opportunity to target the disease process during an early symptomatic stage. Structural magnetic resonance imaging (MRI) measures have been the mainstay of Alzheimer’s disease (AD) imaging research, however, ventricular morphometry analysis remains challenging because of its complicated topological structure. Here we describe a novel ventricular morphometry system based on the hyperbolic Ricci flow method and tensor-based morphometry (TBM) statistics. Unlike prior ventricular surface parameterization methods, hyperbolic conformal parameterization is angle-preserving and does not have any singularities. Our system generates a one-to-one diffeomorphic mapping between ventricular surfaces with consistent boundary matching conditions. The TBM statistics encode a great deal of surface deformation information that could be inaccessible or overlooked by other methods. We applied our system to the baseline MRI scans of a set of MCI subjects from the Alzheimer’s Disease Neuroimaging Initiative (ADNI: 71 MCI converters vs. 62 MCI stable). Although the combined ventricular area and volume features did not differ between the two groups, our fine-grained surface analysis revealed significant differences in the ventricular regions close to the temporal lobe and posterior cingulate, structures that are affected early in AD. Significant correlations were also detected between ventricular morphometry, neuropsychological measures, and a previously described imaging index based on fluorodeoxyglucose positron emission tomography (FDG-PET) scans. This novel ventricular morphometry method may offer a new and more sensitive approach to study preclinical and early symptomatic stage AD. PMID:25285374
Quantitative analysis of regional myocardial performance in coronary artery disease
NASA Technical Reports Server (NTRS)
Stewart, D. K.; Dodge, H. T.; Frimer, M.
1975-01-01
Findings from a group of subjects with significant coronary artery stenosis are given. A group of controls determined by use of a quantitative method for the study of regional myocardial performance based on the frame-by-frame analysis of biplane left ventricular angiograms are presented. Particular emphasis was placed upon the analysis of wall motion in terms of normalized segment dimensions, timing and velocity of contraction. The results were compared with the method of subjective assessment used clinically.
Abdel-karim, Abdul-rahman R.; Main, Michael L.
2016-01-01
Interventricular septal hematoma is a rare complication of retrograde chronic total occlusion (CTO) percutaneous coronary interventions (PCI) with a typically benign course. Here we report two cases of interventricular septal hematoma and coronary-cameral fistula development after right coronary artery (RCA) CTO-PCI using a retrograde approach. Both were complicated by development of ST-segment elevation and chest pain. One case was managed actively and the other conservatively, both with a favorable outcome. PMID:27668097
The overloaded right heart and ventricular interdependence.
Naeije, Robert; Badagliacca, Roberto
2017-10-01
The right and the left ventricle are interdependent as both structures are nested within the pericardium, have the septum in common and are encircled with common myocardial fibres. Therefore, right ventricular volume or pressure overloading affects left ventricular function, and this in turn may affect the right ventricle. In normal subjects at rest, right ventricular function has negligible interaction with left ventricular function. However, the right ventricle contributes significantly to the normal cardiac output response to exercise. In patients with right ventricular volume overload without pulmonary hypertension, left ventricular diastolic compliance is decreased and ejection fraction depressed but without intrinsic alteration in contractility. In patients with right ventricular pressure overload, left ventricular compliance is decreased with initial preservation of left ventricular ejection fraction, but with eventual left ventricular atrophic remodelling and altered systolic function. Breathing affects ventricular interdependence, in healthy subjects during exercise and in patients with lung diseases and altered respiratory system mechanics. Inspiration increases right ventricular volumes and decreases left ventricular volumes. Expiration decreases both right and left ventricular volumes. The presence of an intact pericardium enhances ventricular diastolic interdependence but has negligible effect on ventricular systolic interdependence. On the other hand, systolic interdependence is enhanced by a stiff right ventricular free wall, and decreased by a stiff septum. Recent imaging studies have shown that both diastolic and systolic ventricular interactions are negatively affected by right ventricular regional inhomogeneity and prolongation of contraction, which occur along with an increase in pulmonary artery pressure. The clinical relevance of these observations is being explored. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Hoffmayer, Kurt S; Bhave, Prashant D; Marcus, Gregory M; James, Cynthia A; Tichnell, Crystal; Chopra, Nagesh; Moxey, Laura; Krahn, Andrew D; Dixit, Sanjay; Stevenson, William; Calkins, Hugh; Badhwar, Nitish; Gerstenfeld, Edward P; Scheinman, Melvin M
2013-04-01
Ventricular arrhythmias in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) and idiopathic ventricular tachycardia (VT) can share a left bundle branch block/inferior axis morphology. We previously reported electrocardiogram characteristics during outflow tract ventricular arrhythmias that helped distinguish VT related to ARVD/C from idiopathic VT. To prospectively validate these criteria. We created a risk score by using a derivation cohort. Two experienced electrophysiologists blinded to the diagnosis prospectively scored patients with VT/premature ventricular contractions (PVCs) with left bundle branch block/inferior axis pattern in a validation cohort of 37 ARVD/C tracings and 49 idiopathic VT tracings. All patients with ARVD/C had their diagnosis confirmed based on the revised task force criteria. Patients with idiopathic VT were selected based on structurally normal hearts with documented right ventricular outflow tract VT successfully treated with ablation. The scoring system provides 3 points for sinus rhythm anterior T-wave inversions in leads V1-V3 and during ventricular arrhythmia: 2 points for QRS duration in lead I≥120 ms, 2 points for QRS notching, and 1 point for precordial transition at lead V5 or later. A score of 5 or greater was able to correctly distinguish ARVD/C from idiopathic VT 93% of the time, with a sensitivity of 84%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 91%. We describe a simple scoring algorithm that uses 12-lead electrocardiogram characteristics to effectively distinguish right ventricular outflow tract arrhythmias originating from patients with ARVD/C versus patients with idiopathic VT. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Zhang, Y; Yuan, H Y; Liu, X B; Wen, S S; Xu, G; Cui, H J; Zhuang, J; Chen, J M
2018-06-01
As a result of right ventricular outflow tract reconstruction, which is the important and basic step of complex cardiac surgery, the blood flow of right ventricular outflow tract is unobstructed, while pulmonary valve regurgitation and right heart dysfunction could be happened. These problems are often ignored in early days, more and more cases of right heart dysfunction need clinical intervention, which is quite difficult and less effective. How to protect effectively the right ventricular function is the focus. At present main methods to protect the right ventricular function include trying to avoid or reduce length of right ventricular incision, reserving or rebuilding the function of the pulmonary valve, using growth potential material for surgery. The protection of the right ventricular function is a systemic project, it involves many aspects, single measures is difficult to provide complete protection, only the comprehensive use of various protection strategy, can help to improve the long-term prognosis.
The importance of training in echocardiography: a validation study using pocket echocardiography.
Prinz, Christian; Dohrmann, Jelena; van Buuren, Frank; Bitter, Thomas; Bogunovic, Nikola; Horstkotte, Dieter; Faber, Lothar
2012-11-01
To investigate the training effect in echocardiography by using recent hand-held ultrasound scanners (HANDs). In this prospective study, 320 consecutive patients were scanned with HAND by an inexperienced ultrasonographer over a period of 8 weeks. Imaging studies were compared with high-end echocardiography as gold standard. Segmental endocardial border delineation was scored to describe image quality. Assessment of left ventricular dimensions, regional/global left ventricular function and grading of valve disease were compared. A significant reduction in examination duration, improvement in image quality, substantial agreement in functional assessment (κ > 0.61, P < 0.01) and wall motion scoring (κ=0.67, P < 0.01) could be observed over time. The correlation in left ventricular measurements was excellent (r > 0.98, P < 0.01). The detection of valve diseases and pericardial effusions was sufficient, but the grading only moderate (κ < 0.6). Well-grounded training in echocardiography leads to a rapid improvement in image acquisition and interpretation over a period of a few weeks. Basic diagnostic findings could be interpreted with high accuracy after short training. Interpretation of complex findings remained difficult. The time needed to carry out an examination using pocket echocardiography could not be reduced to less than 3-4 min per patient. New educational concepts are warranted.
Satoh, Hiroshi; Sano, Makoto; Suwa, Kenichiro; Saitoh, Takeji; Nobuhara, Mamoru; Saotome, Masao; Urushida, Tsuyoshi; Katoh, Hideki; Hayashi, Hideharu
2014-01-01
The recent development of cardiac magnetic resonance (CMR) techniques has allowed detailed analyses of cardiac function and tissue characterization with high spatial resolution. We review characteristic CMR features in ischemic and non-ischemic cardiomyopathies (ICM and NICM), especially in terms of the location and distribution of late gadolinium enhancement (LGE). CMR in ICM shows segmental wall motion abnormalities or wall thinning in a particular coronary arterial territory, and the subendocardial or transmural LGE. LGE in NICM generally does not correspond to any particular coronary artery distribution and is located mostly in the mid-wall to subepicardial layer. The analysis of LGE distribution is valuable to differentiate NICM with diffusely impaired systolic function, including dilated cardiomyopathy, end-stage hypertrophic cardiomyopathy (HCM), cardiac sarcoidosis, and myocarditis, and those with diffuse left ventricular (LV) hypertrophy including HCM, cardiac amyloidosis and Anderson-Fabry disease. A transient low signal intensity LGE in regions of severe LV dysfunction is a particular feature of stress cardiomyopathy. In arrhythmogenic right ventricular cardiomyopathy/dysplasia, an enhancement of right ventricular (RV) wall with functional and morphological changes of RV becomes apparent. Finally, the analyses of LGE distribution have potentials to predict cardiac outcomes and response to treatments. PMID:25068019
Ardell, Jeffrey L.; Cardinal, René; Vermeulen, Michel; Armour, J. Andrew
2009-01-01
Populations of intrathoracic extracardiac neurons transduce myocardial ischemia, thereby contributing to sympathetic control of regional cardiac indices during such pathology. Our objective was to determine whether electrical neuromodulation using spinal cord stimulation (SCS) modulates such local reflex control. In 10 anesthetized canines, middle cervical ganglion neurons were identified that transduce the ventricular milieu. Their capacity to transduce a global (rapid ventricular pacing) vs. regional (transient regional ischemia) ventricular stress was tested before and during SCS (50 Hz, 0.2 ms duration at 90% MT) applied to the dorsal aspect of the T1 to T4 spinal cord. Rapid ventricular pacing and transient myocardial ischemia both activated cardiac-related middle cervical ganglion neurons. SCS obtunded their capacity to reflexly respond to the regional ventricular ischemia, but not rapid ventricular pacing. In conclusion, spinal cord inputs to the intrathoracic extracardiac nervous system obtund the latter's capacity to transduce regional ventricular ischemia, but not global cardiac stress. Given the substantial body of literature indicating the adverse consequences of excessive adrenergic neuronal excitation on cardiac function, these data delineate the intrathoracic extracardiac nervous system as a potential target for neuromodulation therapy in minimizing such effects. PMID:19515981
Segmentation of the heart and major vascular structures in cardiovascular CT images
NASA Astrophysics Data System (ADS)
Peters, J.; Ecabert, O.; Lorenz, C.; von Berg, J.; Walker, M. J.; Ivanc, T. B.; Vembar, M.; Olszewski, M. E.; Weese, J.
2008-03-01
Segmentation of organs in medical images can be successfully performed with shape-constrained deformable models. A surface mesh is attracted to detected image boundaries by an external energy, while an internal energy keeps the mesh similar to expected shapes. Complex organs like the heart with its four chambers can be automatically segmented using a suitable shape variablility model based on piecewise affine degrees of freedom. In this paper, we extend the approach to also segment highly variable vascular structures. We introduce a dedicated framework to adapt an extended mesh model to freely bending vessels. This is achieved by subdividing each vessel into (short) tube-shaped segments ("tubelets"). These are assigned to individual similarity transformations for local orientation and scaling. Proper adaptation is achieved by progressively adapting distal vessel parts to the image only after proximal neighbor tubelets have already converged. In addition, each newly activated tubelet inherits the local orientation and scale of the preceeding one. To arrive at a joint segmentation of chambers and vasculature, we extended a previous model comprising endocardial surfaces of the four chambers, the left ventricular epicardium, and a pulmonary artery trunk. Newly added are the aorta (ascending and descending plus arch), superior and inferior vena cava, coronary sinus, and four pulmonary veins. These vessels are organized as stacks of triangulated rings. This mesh configuration is most suitable to define tubelet segments. On 36 CT data sets reconstructed at several cardiac phases from 17 patients, segmentation accuracies of 0.61-0.80mm are obtained for the cardiac chambers. For the visible parts of the newly added great vessels, surface accuracies of 0.47-1.17mm are obtained (larger errors are asscociated with faintly contrasted venous structures).
Human intestinal anisakiosis due to consumption of raw salmon.
Couture, Christian; Measures, Lena; Gagnon, Joël; Desbiens, Christine
2003-08-01
Anisakiosis is a parasitic infection that follows consumption of raw or insufficiently pickled, salted, smoked, or cooked wild marine fish infected with Anisakis sp. larvae. We report a case of intestinal anisakiosis in a 50-year-old man from Quebec who presented with abdominal pain and peripheral eosinophilia after eating raw wild-caught salmon from the Pacific Ocean off Canada. Abdominal CT scan showed bowel distension proximal to a segmental jejunal wall thickening, which was resected. The jejunum segment showed a localized area of serositis with mucosal edema and a submucosal abscess rich in eosinophils surrounding a parasite consistent with the third larval stage of Anisakis sp. Diagnostic morphologic characteristics included an unpaired excretory gland (renette cell), Y-shaped lateral epidermal cords, no apparent reproductive system, and a ventriculus (glandular esophagus). These features and the absence of lateral alae excluded Ascaris sp. The absence of ventricular appendage and intestinal cecum excluded other anisakids of the genera Pseudoterranova and Contracaecum. As the popularity of eating raw fish is growing in North America, anisakiosis may be diagnosed more frequently in surgical specimens. This parasitic infection should be considered in the differential diagnosis of acute abdominal syndromes and eosinophilic infiltrates of the stomach, small intestine, colon, omentum, and mesentery, especially with a history of raw marine fish consumption.
Passive Ventricular Mechanics Modelling Using MRI of Structure and Function
Wang, V.Y.; Lam, H.I.; Ennis, D.B.; Young, A.A.; Nash, M.P.
2009-01-01
Patients suffering from dilated cardiomyopathy or myocardial infarction can develop left ventricular (LV) diastolic impairment. The LV remodels its structure and function to adapt to pathophysiological changes in geometry and loading conditions and this remodeling process can alter the passive ventricular mechanics. In order to better understand passive ventricular mechanics, a LV finite element model was developed to incorporate physiological and mechanical information derived from in vivo magnetic resonance imaging (MRI) tissue tagging, in vivo LV cavity pressure recording and ex vivo diffusion tensor MRI (DTMRI) of a canine heart. MRI tissue tagging enables quantitative evaluation of cardiac mechanical function with high spatial and temporal resolution, whilst the direction of maximum water diffusion (the primary eigenvector) in each voxel of a DTMRI directly correlates with the myocardial fibre orientation. This model was customized to the geometry of the canine LV during diastasis by fitting the segmented epicardial and endocardial surface data from tagged MRI using nonlinear finite element fitting techniques. Myofibre orientations, extracted from DTMRI of the same heart, were incorporated into this geometric model using a free form deformation methodology. Pressure recordings, temporally synchronized to the tissue tagging MRI data, were used to simulate the LV deformation during diastole. Simulation of the diastolic LV mechanics allowed us to estimate the stiffness of the passive LV myocardium based on kinematic data obtained from tagged MRI. This integrated physiological model will allow more insight into the regional passive diastolic mechanics of the LV on an individualized basis, thereby improving our understanding of the underlying structural basis of mechanical dysfunction in pathological conditions. PMID:18982680
Passive ventricular mechanics modelling using MRI of structure and function.
Wang, V Y; Lam, H I; Ennis, D B; Young, A A; Nash, M P
2008-01-01
Patients suffering from dilated cardiomyopathy or myocardial infarction can develop left ventricular (LV) diastolic impairment. The LV remodels its structure and function to adapt to pathophysiological changes in geometry and loading conditions and this remodeling process can alter the passive ventricular mechanics. In order to better understand passive ventricular mechanics, a LV finite element model was developed to incorporate physiological and mechanical information derived from in vivo magnetic resonance imaging (MRI) tissue tagging, in vivo LV cavity pressure recording and ex vivo diffusion tensor MRI (DTMRI) of a canine heart. MRI tissue tagging enables quantitative evaluation of cardiac mechanical function with high spatial and temporal resolution, whilst the direction of maximum water diffusion (the primary eigenvector) in each voxel of a DTMRI directly correlates with the myocardial fibre orientation. This model was customized to the geometry of the canine LV during diastasis by fitting the segmented epicardial and endocardial surface data from tagged MRI using nonlinear finite element fitting techniques. Myofibre orientations, extracted from DTMRI of the same heart, were incorporated into this geometric model using a free form deformation methodology. Pressure recordings, temporally synchronized to the tissue tagging MRI data, were used to simulate the LV deformation during diastole. Simulation of the diastolic LV mechanics allowed us to estimate the stiffness of the passive LV myocardium based on kinematic data obtained from tagged MRI. This integrated physiological model will allow more insight into the regional passive diastolic mechanics of the LV on an individualized basis, thereby improving our understanding of the underlying structural basis of mechanical dysfunction in pathological conditions.
Mouton Paradot, Gaëlle; Baledent, Olivier; Sallioux, Guillaume; Lehmann, Pierre; Gondry-Jouet, Catherine; Le Gars, Daniel
2010-02-01
The diagnosis and management of patients with idiopathic normal-pressure hydrocephalus (NPH) remain somewhat controversial and there is no clear guideline for assessing the post-shunt outcome. The objective of this study was to investigate whether cerebrospinal fluid (CSF) flow dynamics is linked to post-shunt improvement. Fourteen NPH patients (nine males and five females; mean age, 68 years) investigated by magnetic resonance imaging (MRI) before surgical diversion of CSF were retrospectively reviewed. Phase-contrast sequences were added to the morphological clinical protocol for quantification of CSF oscillations, which were recorded at the level of the cerebral aqueduct and the C2 and C3 subarachnoid spaces (SAS). The phase-contrast images were analysed with custom-designed dedicated flow segmentation software. The oscillations measured in this hydrocephalus population were compared to a previously studied healthy population. A difference of at least two standard deviations was used to define a hyperdynamic or hypodynamic state of CSF flow. The cervical CSF flow of the hydrocephalus patients was not significantly different from those of the volunteer population. Of the 14 hydrocephalus patients, 12 had a good response to the shunt. Of these, 10 presented an increased ventricular CSF flow, one a low ventricular CSF flow, and the last one had a normal ventricular CSF flow. Phase-contrast MRI can help develop guidelines for surgical management of NPH. The shunt responders appear to be the patients with hyperdynamic ventricular CSF flow and normal cervical CSF flow. Copyright 2009 Elsevier Masson SAS. All rights reserved.
Tan, Li Kuo; Liew, Yih Miin; Lim, Einly; McLaughlin, Robert A
2017-07-01
Automated left ventricular (LV) segmentation is crucial for efficient quantification of cardiac function and morphology to aid subsequent management of cardiac pathologies. In this paper, we parameterize the complete (all short axis slices and phases) LV segmentation task in terms of the radial distances between the LV centerpoint and the endo- and epicardial contours in polar space. We then utilize convolutional neural network regression to infer these parameters. Utilizing parameter regression, as opposed to conventional pixel classification, allows the network to inherently reflect domain-specific physical constraints. We have benchmarked our approach primarily against the publicly-available left ventricle segmentation challenge (LVSC) dataset, which consists of 100 training and 100 validation cardiac MRI cases representing a heterogeneous mix of cardiac pathologies and imaging parameters across multiple centers. Our approach attained a .77 Jaccard index, which is the highest published overall result in comparison to other automated algorithms. To test general applicability, we also evaluated against the Kaggle Second Annual Data Science Bowl, where the evaluation metric was the indirect clinical measures of LV volume rather than direct myocardial contours. Our approach attained a Continuous Ranked Probability Score (CRPS) of .0124, which would have ranked tenth in the original challenge. With this we demonstrate the effectiveness of convolutional neural network regression paired with domain-specific features in clinical segmentation. Copyright © 2017 Elsevier B.V. All rights reserved.
Dobrowolski, Piotr; Kowalski, Mirosław; Rybicka, Justyna; Lech, Agnieszka; Tyczyński, Paweł; Witkowski, Adam; Hoffman, Piotr
2016-01-01
The aim of this study was to evaluate the potential clinical application of ultrasonic tissue indices, with a focus on systolic strain (SS) and systolic strain rate (SSR) parameters derived from transthoracic echocardiography, in the assessment of left anterior descending artery (LAD) stenosis. The data of 30 patients with significant LAD stenosis were analysed. All patients underwent transthoracic echocardiography to obtain systolic myocardial velocity (Sm), longitudinal SS, and SSR from basal, mid, and apical segments of anterior and inferior walls in two-chamber apical view. Severity of LAD obstruction was measured by means of fractional flow reserve (FFR) during coronary catheterisation. Systolic velocities, strain, and strain rate measured in basal, middle, and apical segments of the anterior left ventricular (LV) wall were lower when compared to those obtained from the corresponding, i.e. unaffected, inferior LV wall. There was a significant correlation between FFR and the value of SS, SSR characterising the apical LV segment of the anterior wall (r = -0.583, p = 0.01; r = -0.598, p = 0.01, respectively). Moreover, we found significant correlation between FFR and Sm in the mid-segment of the LV anterior wall (r = 0.611, p = 0.009). We conclude that SS and SSR obtained from the apical segment of the anterior LV wall may be related to the severity of LAD stenosis.
NASA Technical Reports Server (NTRS)
Reiber, J. H. C.
1976-01-01
To automate the data acquisition procedure, a real-time contour detection and data acquisition system for the left ventricular outline was developed using video techniques. The X-ray image of the contrast-filled left ventricle is stored for subsequent processing on film (cineangiogram), video tape or disc. The cineangiogram is converted into video format using a television camera. The video signal from either the TV camera, video tape or disc is the input signal to the system. The contour detection is based on a dynamic thresholding technique. Since the left ventricular outline is a smooth continuous function, for each contour side a narrow expectation window is defined in which the next borderpoint will be detected. A computer interface was designed and built for the online acquisition of the coordinates using a PDP-12 computer. The advantage of this system over other available systems is its potential for online, real-time acquisition of the left ventricular size and shape during angiocardiography.
Koutsarnakis, Christos; Liakos, Faidon; Kalyvas, Aristotelis V; Liouta, Evangelia; Emelifeonwu, John; Kalamatianos, Theodosis; Sakas, Damianos E; Johnson, Elizabeth; Stranjalis, George
2017-08-01
Although the operative corridor used during the intraparietal transsulcal approach to the atrium has been previously investigated, most anatomical studies focus on its relationship to the optic radiations. To study the intraparietal sulcus (IPS) morphology and to explore the subcortical anatomy with regard to the surgical trajectory used during the intraparietal transsulcal tranventricular approach. Twenty-five adult, formalin fixed, cerebral hemispheres were investigated. Fifteen underwent the Klingler procedure and were dissected in a lateromedial direction using the fiber microdissection technique. The trajectory of the dissection resembled that of real operative settings. The remaining 10 hemispheres were cut along the longitudinal axis of the sulcus in order to correlate its surface anatomy to corresponding parts of the ventricular system. IPS demonstrated an interrupted course in 36% of the specimens while its branching pattern was variable. The sulcus anterior half was found to overly the atrium in all occasions. Four discrete, consecutive white matter layers were identified en route to the atrium, ie, the arcuate fibers, the arcuate segment of the superior longitudinal fasciculus, the corona radiata and tapetum, with the arcuate segment being near to the dissection trajectory. Given the angle of brain transgression during the intraparietal approach, we found the optimal dissection area to be the very middle of the sulcus. The IPS-postcentral sulcus meeting point, in contrast to previous thought, proved to risk potential injury to the arcuate segment of the superior longitudinal fasciculus, thus affecting surgical outcome. Copyright © 2017 by the Congress of Neurological Surgeons
NASA Astrophysics Data System (ADS)
Ellingsen, Lotta M.; Roy, Snehashis; Carass, Aaron; Blitz, Ari M.; Pham, Dzung L.; Prince, Jerry L.
2016-03-01
Normal pressure hydrocephalus (NPH) affects older adults and is thought to be caused by obstruction of the normal flow of cerebrospinal fluid (CSF). NPH typically presents with cognitive impairment, gait dysfunction, and urinary incontinence, and may account for more than five percent of all cases of dementia. Unlike most other causes of dementia, NPH can potentially be treated and the neurological dysfunction reversed by shunt surgery or endoscopic third ventriculostomy (ETV), which drain excess CSF. However, a major diagnostic challenge remains to robustly identify shunt-responsive NPH patients from patients with enlarged ventricles due to other neurodegenerative diseases. Currently, radiologists grade the severity of NPH by detailed examination and measurement of the ventricles based on stacks of 2D magnetic resonance images (MRIs). Here we propose a new method to automatically segment and label different compartments of the ventricles in NPH patients from MRIs. While this task has been achieved in healthy subjects, the ventricles in NPH are both enlarged and deformed, causing current algorithms to fail. Here we combine a patch-based tissue classification method with a registration-based multi-atlas labeling method to generate a novel algorithm that labels the lateral, third, and fourth ventricles in subjects with ventriculomegaly. The method is also applicable to other neurodegenerative diseases such as Alzheimer's disease; a condition considered in the differential diagnosis of NPH. Comparison with state of the art segmentation techniques demonstrate substantial improvements in labeling the enlarged ventricles, indicating that this strategy may be a viable option for the diagnosis and characterization of NPH.
The double switch for atrioventricular discordance.
Brawn, William J
2005-01-01
Conventional surgery for atrioventricular discordance usually associated with ventricular arterial discordance leaves the morphologic right ventricle in the systemic circulation. Long-term follow-up results with this approach reveal a high incidence of right ventricular failure. The double switch procedure was introduced to restore the morphologic left ventricle to the systemic circulation. This operation is performed in two main ways: the atrial-arterial switch and the atrial switch plus Rastelli procedure. This double switch approach has been successful at least in the medium term in abolishing morphologic right ventricular failure and its associated tricuspid valve regurgitation. In the atrial-arterial switch group, there is an incidence of morphologic left ventricular dysfunction, sometimes associated with neoaortic valve regurgitation, and the minority of cases need aortic valve replacement. The long-term function of the morphologic left ventricle and the aortic valve need careful surveillance in the future. The atrial-Rastelli group of patients has not in the medium term shown evidence of ventricular dysfunction but will require change on a regular basis of their ventricular to pulmonary artery valved conduits.
Zheng, Huan; Xie, Nanzi; Xu, Huifeng; Huang, Junling; Xie, Xiaoyun; Luo, Ming
2016-03-01
We sought to investigate effects of supervised exercise training on left ventricular remodeling, left ventricular function and autonomic nervous system of hypertensive patients without medication. Fifty borderline and mildly hypertensive patients were enrolled and randomly divided into 2 groups (25 in each). Exercise group received a 4 months' exercise program, prescribed according to their first cardiopulmonary exercise tests, while the control group received routine dietary recommendation. All patients underwent noradrenalin assay, cardiopulmonary exercise tests and echocardiographic studies at enrollment and 4 month follow-up. At baseline no statistically difference between the two groups were observed in clinical characteristics, echographic variants or cardiopulmonary test index. Four months later, exercise group showed higher values of VO2peak, Powermax (max workload), AT (anaerobic threshold), VO2AT (VO2 at anaerobic threshold), tAT (time from beginning to anaerobic threshold) and heart rate recovery compared to the control group (P<0.05). Additionally, systolic/diastolic blood pressure decreased significantly in the exercise group compared to the control group (P<0.05). Moreover, there was significant reduction in left ventricular mass index in the exercise group (P<0.01), and there was also an inverse correlation between changes in left ventricular mass index and heart rate recovery (r=-0.52, P<0.01). Four-month exercise training in borderline and mildly hypertensive patients not only decreased their blood pressure levels, but also induced an improvement of exercise capability, left ventricular remodeling and heart rate recovery. Heart rate recovery improvement was significantly associated with decrease of left ventricular mass index, which indicated that favorable adjustment in autonomic nervous system of exercise training might be an important pathway to reverse left ventricular remodeling.
Implantable physiologic controller for left ventricular assist devices with telemetry capability.
Asgari, Siavash S; Bonde, Pramod
2014-01-01
Rotary type left ventricular assist devices have mitigated the problem of durability associated with earlier pulsatile pumps and demonstrated improved survival. However, the compromise is the loss of pulsatility due to continuous flow and retained percutaneous driveline leading to increased mortality and morbidity. Lack of pulsatility is implicated in increased gastrointestinal bleeding, aortic incompetence, and diastolic hypertension. We present a novel, wirelessly powered, ultra-compact, implantable physiologic controller capable of running a left ventricular assist device in a pulsatile mode with wireless power delivery. The schematic of our system was laid out on a circuit board to wirelessly receive power and run a left ventricular assist device with required safety and backup measures. We have embedded an antenna and wireless network for telemetry. Multiple signal processing steps and controlling algorithm were incorporated. The controller was tested in in vitro and in vivo experiments. The controller drove left ventricular assist devices continuously for 2 weeks in an in vitro setup and in vivo without any failure. Our controller is more power efficient than the current Food and Drug Administration-approved left ventricular assist device controllers. When used with electrocardiography synchronization, the controller allowed on-demand customization of operation with instantaneous flow and revolutions per minute changes, resulting in a pulsatile flow with adjustable pulse pressure. Our test results prove the system to be remarkably safe, accurate, and efficient. The unique combination of wireless powering and small footprint makes this system an ideal totally implantable physiologic left ventricular assist device system. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
van der Bom, Teun; Winter, Michiel M; Bouma, Berto J; Groenink, Maarten; Vliegen, Hubert W; Pieper, Petronella G; van Dijk, Arie P J; Sieswerda, Gertjan T; Roos-Hesselink, Jolien W; Zwinderman, Aeilko H; Mulder, Barbara J M
2013-01-22
The role of angiotensin II receptor blockers in patients with a systemic right ventricle has not been elucidated. We conducted a multicenter, double-blind, parallel, randomized controlled trial of angiotensin II receptor blocker valsartan 160 mg twice daily compared with placebo in patients with a systemic right ventricle caused by congenitally or surgically corrected transposition of the great arteries. The primary end point was change in right ventricular ejection fraction during 3-year follow-up, determined by cardiovascular magnetic resonance imaging or, in patients with contraindication for magnetic resonance imaging, multirow detector computed tomography. Secondary end points were change in right ventricular volumes and mass, Vo(2)peak, and quality of life. Primary analyses were performed on an intention-to-treat basis. A total of 88 patients (valsartan, n=44; placebo, n=44) were enrolled in the trial. No serious adverse effects occurred in either group. There was no significant effect of 3-year valsartan therapy on systemic right ventricular ejection fraction (treatment effect, 1.3%; 95% confidence interval, -1.3% to 3.9%; P=0.34), maximum exercise capacity, or quality of life. There was a larger increase in right ventricular end-diastolic volume (15 mL; 95% confidence interval, 3-28 mL; P<0.01) and mass (8 g; 95% confidence interval, 2-14 g; P=0.01) in the placebo group than in the valsartan group. There was no significant treatment effect of valsartan on right ventricular ejection fraction, exercise capacity, or quality of life. Valsartan was associated with a similar frequency of significant clinical events as placebo. Small but significant differences between valsartan and placebo were present for change in right ventricular volumes and mass. URL: http://www.controlled-trials.com. Unique identifier: ISRCTN52352170.
Virdis, A; Ghiadoni, L; Lucarini, A; Di Legge, V; Taddei, S; Salvetti, A
1996-04-01
In asymptomatic essential hypertensive patients with angiographically normal coronary arteries and without left ventricular hypertrophy, dipyridamole-induced ischemic-like ST segment depression may be a marker of coronary microvascular disease. In this study we evaluated, first, whether this cardiac abnormality is linked to structural or functional vascular abnormalities, and second, the effect of antihypertensive treatment by 12-month administration of the angiotensin converting enzyme (ACE) inhibitor captopril (50 mg twice a day orally). In essential hypertensives with dipypridamole echocardiography stress test (DET) (DET+, n = 8) and without (DET-, n = 8) ST segment depression greater than 0.1 mV during intravenous dipyridamole infusion (0.84 mg/kg over 10 min), we studied the forearm blood flow (FBF, venous plethysmography, mL/100) modifications induced by intrabrachial acetylcholine (Ach) (0.15, 0.45, 1.5, 4.5, 15 micrograms/100 mL/min x 5 min each), an endothelium-dependent vasodilator, and by sodium nitroprusside (SNP) (1, 2, 4 micrograms/100 mL/min x 5 min each), a smooth muscle cell relaxant compound. Minimal forearm vascular resistances (MFVR), an index of arteriolar structural changes, were also calculated. Both Ach and SNP caused greater vasodilation in DET- as compared to DET+ while MFVRs were lower in DET- compared to DET+. After treatment, both DET+ and DET- patients showed a significant and similar reduction in blood pressure and left ventricular mass index, while vasodilation to acetylcholine and sodium nitroprusside was increased only in the DET+ group. In addition, forearm minimal vascular resistances were significantly reduced only in DET+ patients, who showed disappearance of dipyridamole-induced ischemic-like ST segment depression. In conclusion, these data confirm that essential hypertensive patients with microvascular coronary disease are characterized by the presence of structural changes in the forearm vascular bed. Our results also indicate that both cardiac and forearm vascular abnormalities can be reversed by antihypertensive treatment with an ACE inhibitor.
Rodrigues, Jonathan C L; Rohan, Stephen; Ghosh Dastidar, Amardeep; Harries, Iwan; Lawton, Christopher B; Ratcliffe, Laura E; Burchell, Amy E; Hart, Emma C; Hamilton, Mark C K; Paton, Julian F R; Nightingale, Angus K; Manghat, Nathan E
2017-03-01
European guidelines state left ventricular (LV) end-diastolic wall thickness (EDWT) ≥15mm suggests hypertrophic cardiomyopathy (HCM), but distinguishing from hypertensive heart disease (HHD) is challenging. We identify cardiovascular magnetic resonance (CMR) predictors of HHD over HCM when EDWT ≥15mm. 2481 consecutive clinical CMRs between 2014 and 2015 were reviewed. 464 segments from 29 HCM subjects with EDWT ≥15mm but without other cardiac abnormality, hypertension or renal impairment were analyzed. 432 segments from 27 HHD subjects with EDWT ≥15mm but without concomitant cardiac pathology were analyzed. Magnitude and location of maximal EDWT, presence of late gadolinium enhancement (LGE), LV asymmetry (>1.5-fold opposing segment) and systolic anterior motion of the mitral valve (SAM) were measured. Multivariate logistic regression was performed. Significance was defined as p<0.05. HHD and HCM cohorts were age-/gender-matched. HHD had significantly increased indexed LV mass (110±27g/m 2 vs. 91±31g/m 2 , p=0.016) but no difference in site or magnitude of maximal EDWT. Mid-wall LGE was significantly more prevalent in HCM. Elevated indexed LVM, mid-wall LGE and absence of SAM were significant multivariate predictors of HHD, but LV asymmetry was not. Increased indexed LV mass, absence of mid-wall LGE and absence of SAM are better CMR discriminators of HHD from HCM than EDWT ≥15mm. • Hypertrophic cardiomyopathy (HCM) is often diagnosed with end-diastolic wall thickness ≥15mm. • Hypertensive heart disease (HHD) can be difficult to distinguish from HCM. • Retrospective case-control study showed that location and magnitude of EDWT are poor discriminators. • Increased left ventricular mass and midwall fibrosis are independent predictors of HHD. • Cardiovascular magnetic resonance parameters facilitate a better discrimination between HHD and HCM.
Badagliacca, Roberto; Poscia, Roberto; Pezzuto, Beatrice; Papa, Silvia; Gambardella, Cristina; Francone, Marco; Mezzapesa, Mario; Nocioni, Martina; Nona, Alfred; Rosati, Riccardo; Sciomer, Susanna; Fedele, Francesco; Dario Vizza, Carmine
2015-03-01
Right ventricular (RV) dyssynchrony has been described in pulmonary arterial hypertension (PAH), but no evidence is available on its morphologic determinants and its effect on systolic function. The aim of this study was to evaluate the morphologic determinants of RV dyssynchrony by echocardiographic and cardiac magnetic resonance imaging and its effect on systolic function. In 60 consecutive idiopathic PAH (IPAH) patients with narrow QRS, RV dyssynchrony was evaluated by 2D speckle-tracking echocardiography, calculating the standard deviation of the times to peak systolic strain for the four mid-basal RV segments (RV-SD4). Patients were grouped by the median value of RV-SD4 (19 milliseconds) and compared for RV remodeling and systolic function parameters, WHO class, pulmonary hemodynamics and 6-minute walk test (6MWT). Despite similar pulmonary vascular resistance and mean pulmonary arterial pressure, patients with RV-SD4 at >19 milliseconds had advanced WHO class and worse 6MWT, RV hemodynamics, RV remodeling and systolic function parameters compared with patients at ≤19 milliseconds. The morphologic determinants of RV dyssynchrony resulted RV end-diastolic area, LV diastolic eccentricity index and RV mass volume ratio (r = 0.69, r(2) = 0.47, p < 0.0001). Finally, we found a significant inverse correlation between RV mid-basal segments post-systolic shortening time and cardiac index (r = -0.64, r(2) = 0.41, p = 0.001), accounting for the significant correlation between RV-SD4 and cardiac index (r = 0.57, r(2) = 0.32, p = 0.003). In IPAH with narrow QRS, RV dyssynchrony is associated with RV dilation and eccentric hypertrophy pattern, suggesting a role of segmental wall stress heterogeneity as the major determinant of mechanical delay. Post-systolic shortening, as inefficient contraction, contributes to pump dysfunction. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Voeller, Rochus K.; Aziz, Abdulhameed; Maniar, Hersh S.; Ufere, Nneka N.; Taggar, Ajay K.; Bernabe, Noel J.; Cupps, Brian P.
2011-01-01
Increased right atrial (RA) and ventricular (RV) chamber volumes are a late maladaptive response to chronic pulmonary hypertension. The purpose of the current investigation was to characterize the early compensatory changes that occur in the right heart during chronic RV pressure overload before the development of chamber dilation. Magnetic resonance imaging with radiofrequency tissue tagging was performed on dogs at baseline and after 10 wk of pulmonary artery banding to yield either mild RV pressure overload (36% rise in RV pressure; n = 5) or severe overload (250% rise in RV pressure; n = 4). The RV free wall was divided into three segments within a midventricular plane, and circumferential myocardial strain was calculated for each segment, the septum, and the left ventricle. Chamber volumes were calculated from stacked MRI images, and RA mechanics were characterized by calculating the RA reservoir, conduit, and pump contribution to RV filling. With mild RV overload, there were no changes in RV strain or RA function. With severe RV overload, RV circumferential strain diminished by 62% anterior (P = 0.04), 42% inferior (P = 0.03), and 50% in the septum (P = 0.02), with no change in the left ventricle (P = 0.12). RV filling became more dependent on RA conduit function, which increased from 30 ± 9 to 43 ± 13% (P = 0.01), than on RA reservoir function, which decreased from 47 ± 6 to 33 ± 4% (P = 0.04), with no change in RA pump function (P = 0.94). RA and RV volumes and RV ejection fraction were unchanged from baseline during either mild (P > 0.10) or severe RV pressure overload (P > 0.53). In response to severe RV pressure overload, RV myocardial strain is segmentally diminished and RV filling becomes more dependent on RA conduit rather than reservoir function. These compensatory mechanisms of the right heart occur early in chronic RV pressure overload before chamber dilation develops. PMID:21926343
Capitanio, Selene; Nanni, Cristina; Marini, Cecilia; Bonfiglioli, Rachele; Martignani, Cristian; Dib, Bassam; Fuccio, Chiara; Boriani, Giuseppe; Picori, Lorena; Boschi, Stefano; Morbelli, Silvia; Fanti, Stefano; Sambuceti, Gianmario
2015-11-01
Cardiac resynchronization therapy (CRT) is an accepted treatment in patients with end-stage heart failure. PET permits the absolute quantification of global and regional homogeneity in cardiac sympathetic innervation. We evaluated the variation of cardiac adrenergic activity in patients with idiopathic heart failure (IHF) disease (NYHA III-IV) after CRT using (11)C-hydroxyephedrine (HED) PET/CT. Ten IHF patients (mean age = 68; range = 55-81; average left ventricular ejection fraction 26 ± 4%) implanted with a resynchronization device underwent three HED PET/CT studies: PET 1 one week after inactive device implantation; PET 2, one week after PET 1 under stimulated rhythm; PET 3, at 3 months under active CRT. A dedicated software (PMOD 3.4 version) was used to estimate global and regional cardiac uptake of HED through 17 segment polar maps. At baseline, HED uptake was heterogeneously distributed throughout the left ventricle with a variation coefficient of 18 ± 5%. This variable markedly decreased after three months CRT (12 ± 5%, p < 0.01). Interestingly, subdividing the 170 myocardial segments (17 segments of each patient multiplied by the number of patients) into two groups, according to the median value of tracer uptake expressed as % of maximal myocardial uptake (76%), we observed a different behaviour depending on baseline innervation: HED uptake significantly increased only in segments with "impaired innervation" (SUV 2.61 ± 0.92 at PET1 and 3.05 ± 1.67 at three months, p < 0.01). As shown by HED PET/CT uptake and distribution, improvement in homogeneity of myocardial neuronal function reflected a selective improvement of tracer uptake in regions with more severe neuronal damage. These finding supported the presence of a myocardial regional variability in response of cardiac sympathetic system to CRT and a systemic response involving remote tissues with rich adrenergic innervation. This work might contribute to identify imaging parameters that could predict the response to CRT therapy. Copyright © 2015 Elsevier Inc. All rights reserved.
Quyyumi, Arshed A; Vasquez, Alejandro; Kereiakes, Dean J; Klapholz, Marc; Schaer, Gary L; Abdel-Latif, Ahmed; Frohwein, Stephen; Henry, Timothy D; Schatz, Richard A; Dib, Nabil; Toma, Catalin; Davidson, Charles J; Barsness, Gregory W; Shavelle, David M; Cohen, Martin; Poole, Joseph; Moss, Thomas; Hyde, Pamela; Kanakaraj, Anna Maria; Druker, Vitaly; Chung, Amy; Junge, Candice; Preti, Robert A; Smith, Robin L; Mazzo, David J; Pecora, Andrew; Losordo, Douglas W
2017-01-20
Despite direct immediate intervention and therapy, ST-segment-elevation myocardial infarction (STEMI) victims remain at risk for infarct expansion, heart failure, reinfarction, repeat revascularization, and death. To evaluate the safety and bioactivity of autologous CD34+ cell (CLBS10) intracoronary infusion in patients with left ventricular dysfunction post STEMI. Patients who underwent successful stenting for STEMI and had left ventricular dysfunction (ejection fraction≤48%) ≥4 days poststent were eligible for enrollment. Subjects (N=161) underwent mini bone marrow harvest and were randomized 1:1 to receive (1) autologous CD34+ cells (minimum 10 mol/L±20% cells; N=78) or (2) diluent alone (N=83), via intracoronary infusion. The primary safety end point was adverse events, serious adverse events, and major adverse cardiac event. The primary efficacy end point was change in resting myocardial perfusion over 6 months. No differences in myocardial perfusion or adverse events were observed between the control and treatment groups, although increased perfusion was observed within each group from baseline to 6 months (P<0.001). In secondary analyses, when adjusted for time of ischemia, a consistently favorable cell dose-dependent effect was observed in the change in left ventricular ejection fraction and infarct size, and the duration of time subjects was alive and out of hospital (P=0.05). At 1 year, 3.6% (N=3) and 0% deaths were observed in the control and treatment group, respectively. This PreSERVE-AMI (Phase 2, randomized, double-blind, placebo-controlled trial) represents the largest study of cell-based therapy for STEMI completed in the United States and provides evidence supporting safety and potential efficacy in patients with left ventricular dysfunction post STEMI who are at risk for death and major morbidity. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01495364. © 2016 American Heart Association, Inc.
Sengupta, Partho P; Mehta, Vimal; Arora, Ramesh; Mohan, Jagdish C; Khandheria, Bijoy K
2005-07-01
This study tested the hypothesis that linear mapping of regional myocardial strain comprehensively assesses variations in regional myocardial function in hypertrophic cardiomyopathy. Hypertrophic cardiomyopathy is characterized by disorganized myocardial architecture that results in spatial and temporal nonuniformity of regional function. Left ventricular deformation was quantified in 20 patients with hypertrophic cardiomyopathy and compared with 25 age- and sex-matched control subjects. Abnormalities in subendocardial strain ranged from reduced longitudinal shortening to paradoxical systolic lengthening and delayed regional longitudinal contractions that were often located in small subsegmental areas. These variations were underestimated significantly by arbitrary measurements compared with linear mapping, in which a region of interest was moved across the longitudinal length of left ventricle (difference of peak and least strain, 10.7% +/- 5.1% vs 17% +/- 5.5%; P < .001). Echocardiographic assessment of variations in regional strain requires careful mapping and may be inappropriately assessed if left ventricular segments are sampled at arbitrary focal locations.
Westhoff-Bleck, Mechthild; Schieffer, Bernhard; Tegtbur, Uwe; Meyer, Gerd Peter; Hoy, Ludwig; Schaefer, Arnd; Tallone, Ezequiel Marcello; Tutarel, Oktay; Mertins, Ramona; Wilmink, Lena Mara; Anker, Stefan D; Bauersachs, Johann; Roentgen, Philipp
2013-12-05
Exercise training safely and efficiently improves symptoms in patients with heart failure due to left ventricular dysfunction. However, studies in congenital heart disease with systemic right ventricle are scarce and results are controversial. In a randomised controlled study we investigated the effect of aerobic exercise training on exercise capacity and systemic right ventricular function in adults with d-transposition of the great arteries after atrial redirection surgery (28.2 ± 3.0 years after Mustard procedure). 48 patients (31 male, age 29.3 ± 3.4 years) were randomly allocated to 24 weeks of structured exercise training or usual care. Primary endpoint was the change in maximum oxygen uptake (peak VO2). Secondary endpoints were systemic right ventricular diameters determined by cardiac magnetic resonance imaging (CMR). Data were analysed per intention to treat analysis. At baseline peak VO2 was 25.5 ± 4.7 ml/kg/min in control and 24.0 ± 5 ml/kg/min in the training group (p=0.3). Training significantly improved exercise capacity (treatment effect for peak VO2 3.8 ml/kg/min, 95% CI: 1.8 to 5.7; p=0.001), work load (p=0.002), maximum exercise time (p=0.002), and NYHA class (p=0.046). Systemic ventricular function and volumes determined by CMR remained unchanged. None of the patients developed signs of cardiac decompensation or arrhythmias while on exercise training. Aerobic exercise training did not detrimentally affect systemic right ventricular function, but significantly improved exercise capacity and heart failure symptoms. Aerobic exercise training can be recommended for patients following atrial redirection surgery to improve exercise capacity and to lessen or prevent heart failure symptoms. ( ClinicalTrials.gov #NCT00837603). © 2013.
Chen, Shou-Qiang; Xing, Shan-Shan; Gao, Hai-Qing
2014-01-01
Objective: In addition to ambulatory Holter electrocardiographic recording and transtelephonic electrocardiographic monitoring (TTM), a cardiac remote monitoring system can provide an automatic warning function through the general packet radio service (GPRS) network, enabling earlier diagnosis, treatment and improved outcome of cardiac diseases. The purpose of this study was to estimate its clinical significance in preventing acute cardiac episodes. Methods: Using 2 leads (V1 and V5 leads) and the automatic warning mode, 7160 patients were tested with a cardiac remote monitoring system from October 2004 to September 2007. If malignant arrhythmias or obvious ST-T changes appeared in the electrocardiogram records was automatically transferred to the monitoring center, the patient and his family members were informed, and the corresponding precautionary or therapeutic measures were implemented immediately. Results: In our study, 274 cases of malignant arrhythmia, including sinus standstill and ventricular tachycardia, and 43 cases of obvious ST-segment elevation were detected and treated. Because of early detection, there was no death or deformity. Conclusions: A cardiac remote monitoring system providing an automatic warning function can play an important role in preventing acute cardiac episodes. PMID:25674124
[Corrected transposition of the great arteries].
Alva-Espinosa, Carlos
2016-01-01
Corrected transposition of the great arteries is one of the most fascinating entities in congenital heart disease. The apparent corrected condition is only temporal. Over time, most patients develop systemic heart failure, even in the absence of associated lesions. With current imaging studies, precise visualization is achieved in each case though the treatment strategy remains unresolved. In asymptomatic patients or cases without associated lesions, focalized follow-up to assess systemic ventricular function and the degree of tricuspid valve regurgitation is important. In cases with normal ventricular function and mild tricuspid failure, it seems unreasonable to intervene surgically. In patients with significant associated lesions, surgery is indicated. In the long term, the traditional approach may not help tricuspid regurgitation and systemic ventricular failure. Anatomical correction is the proposed alternative to ease the right ventricle overload and to restore the systemic left ventricular function. However, this is a prolonged operation and not without risks and long-term complications. In this review the clinical, diagnostic, and therapeutic aspects are overviewed in the light of the most significant and recent literature.
Vigneault, Davis M; Xie, Weidi; Ho, Carolyn Y; Bluemke, David A; Noble, J Alison
2018-05-22
Pixelwise segmentation of the left ventricular (LV) myocardium and the four cardiac chambers in 2-D steady state free precession (SSFP) cine sequences is an essential preprocessing step for a wide range of analyses. Variability in contrast, appearance, orientation, and placement of the heart between patients, clinical views, scanners, and protocols makes fully automatic semantic segmentation a notoriously difficult problem. Here, we present Ω-Net (Omega-Net): A novel convolutional neural network (CNN) architecture for simultaneous localization, transformation into a canonical orientation, and semantic segmentation. First, an initial segmentation is performed on the input image; second, the features learned during this initial segmentation are used to predict the parameters needed to transform the input image into a canonical orientation; and third, a final segmentation is performed on the transformed image. In this work, Ω-Nets of varying depths were trained to detect five foreground classes in any of three clinical views (short axis, SA; four-chamber, 4C; two-chamber, 2C), without prior knowledge of the view being segmented. This constitutes a substantially more challenging problem compared with prior work. The architecture was trained using three-fold cross-validation on a cohort of patients with hypertrophic cardiomyopathy (HCM, N=42) and healthy control subjects (N=21). Network performance, as measured by weighted foreground intersection-over-union (IoU), was substantially improved for the best-performing Ω-Net compared with U-Net segmentation without localization or orientation (0.858 vs 0.834). In addition, to be comparable with other works, Ω-Net was retrained from scratch using five-fold cross-validation on the publicly available 2017 MICCAI Automated Cardiac Diagnosis Challenge (ACDC) dataset. The Ω-Net outperformed the state-of-the-art method in segmentation of the LV and RV bloodpools, and performed slightly worse in segmentation of the LV myocardium. We conclude that this architecture represents a substantive advancement over prior approaches, with implications for biomedical image segmentation more generally. Published by Elsevier B.V.
Electronic circuit detects left ventricular ejection events in cardiovascular system
NASA Technical Reports Server (NTRS)
Gebben, V. D.; Webb, J. A., Jr.
1972-01-01
Electronic circuit processes arterial blood pressure waveform to produce discrete signals that coincide with beginning and end of left ventricular ejection. Output signals provide timing signals for computers that monitor cardiovascular systems. Circuit operates reliably for heart rates between 50 and 200 beats per minute.
Nogami, Yoshie; Ishizu, Tomoko; Atsumi, Akiko; Yamamoto, Masayoshi; Kawamura, Ryo; Seo, Yoshihiro; Aonuma, Kazutaka
2013-03-01
Recently developed vector flow mapping (VFM) enables evaluation of local flow dynamics without angle dependency. This study used VFM to evaluate quantitatively the index of intraventricular haemodynamic kinetic energy in patients with left ventricular (LV) diastolic dysfunction and to compare those with normal subjects. We studied 25 patients with estimated high left atrial (LA) pressure (pseudonormal: PN group) and 36 normal subjects (control group). Left ventricle was divided into basal, mid, and apical segments. Intraventricular haemodynamic energy was evaluated in the dimension of speed, and it was defined as the kinetic energy index. We calculated this index and created time-energy index curves. The time interval from electrocardiogram (ECG) R wave to peak index was measured, and time differences of the peak index between basal and other segments were defined as ΔT-mid and ΔT-apex. In both groups, early diastolic peak kinetic energy index in mid and apical segments was significantly lower than that in the basal segment. Time to peak index did not differ in apex, mid, and basal segments in the control group but was significantly longer in the apex than that in the basal segment in the PN group. ΔT-mid and ΔT-apex were significantly larger in the PN group than the control group. Multiple regression analysis showed sphericity index, E/E' to be significant independent variables determining ΔT apex. Retarded apical kinetic energy fluid dynamics were detected using VFM and were closely associated with LV spherical remodelling in patients with high LA pressure.
Yambe, T; Hashimoto, H; Kobayashi, S; Sonobe, T; Naganuma, S; Nanka, S S; Matsuki, H; Yoshizawa, M; Tabayashi, K; Takayasu, H; Takeda, H; Nitta, S
1997-01-01
We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.
Potdar, Anil; Sharma, Satyavan
2015-12-01
'No-reflow' phenomenon is a common occurrence in percutaneous coronary intervention (PCI). A three-component 'MAP strategy' was designed to prevent no-reflow by addressing both intralesional and intraluminal thrombus in patients with ST-segment elevation myocardial infarction (STEMI). In this analysis, we observed Thrombolysis In Myocardial Infarction (TIMI) flow grade 3 or 2 in all patients, with no incidence of no-reflow. Myocardial blush grade (MBG) 3 or 2 was observed in most (87.32%) patients. Left ventricular ejection fraction (LVEF) was improved, without any incidence of death up to 9-month follow-up. All patients safely tolerated the strategy-driven prolonged, 35-s inflation of the balloon/stent. Copyright © 2016. Published by Elsevier B.V.
Positron Emission Tomography of the Heart
DOE R&D Accomplishments Database
Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.
1979-01-01
Positron emission computed tomography (PCT) represents an important new tool for the noninvasive evaluation and, more importantly, quantification of myocardial performance. Most currently available techniques permit assessment of only one aspect of cardiac function, i.e., myocardial perfusion by gamma scintillation camera imaging with Thallium-201 or left ventricular function by echocardiography or radionuclide angiocardiography. With PCT it may become possible to study all three major segments of myocardial performance, i.e., regional blood flow, mechanical function and, most importantly, myocardial metabolism. Each of these segments can either be evaluated separately or in combination. This report briefly describes the principles and technological advantages of the imaging device, reviews currently available radioactive tracers and how they can be employed for the assessment of flow, function and metabolism; and, lastly, discusses possible applications of PCT for the study of cardiac physiology or its potential role in the diagnosis of cardiac disease.
Maslow, Andrew; Schwartz, Carl; Mahmood, Feroze; Singh, Arun; Heerdt, Paul M
2009-07-01
In this report, a case of right ventricular (RV) failure, hemodynamic instability, and systemic organ failure is described to highlight how paradoxical ventricular systolic septal motion (PVSM), or a rightward systolic displacement of the interventricular septum, may contribute to RV ejection. Multiple inotropic medications and vasopressors were administered to treat right heart failure and systemic hypotension in a patient following combined aortic and mitral valve replacement. In the early postoperative period, echocardiographic evaluation revealed adequate left ventricular systolic function, akinesis of the RV myocardial tissues, and PVSM. In the presence of PVSM, RV fractional area of contraction was > or =35% despite akinesis of the primary RV myocardial walls. The PVSM appeared to contribute toward RV ejection. As a result, the need for multiple inotropes was re-evaluated, in considering that end-organ dysfunction was the result of systemic hypotension and prolonged vasopressor administration. After discontinuation of phosphodiesterase inhibitors, native vascular tone returned and the need for vasopressors declined. This was followed by recovery of systemic organ function. Echocardiographic re-evaluation two years later, revealed persistent akinesis of the RV myocardial tissues and PVSM, the latter appearing to contribute toward RV ejection. This case highlights the importance of left to RV interactions, and how PVSM may mediate these hemodynamic interactions.
Kirchmaier, Bettina C.; Poon, Kar Lai; Schwerte, Thorsten; Huisken, Jan; Winkler, Christoph; Jungblut, Benno; Stainier, Didier Y.; Brand, Thomas
2013-01-01
The Popeye domain containing (Popdc) genes encode a family of transmembrane proteins with an evolutionary conserved Popeye domain. These genes are abundantly expressed in striated muscle tissue, however their function is not well understood. In this study we have investigated the role of the popdc2 gene in zebrafish. Popdc2 transcripts were detected in the embryonic myocardium and transiently in the craniofacial and tail musculature. Morpholino oligonucleotide-mediated knockdown of popdc2 resulted in aberrant development of skeletal muscle and heart. Muscle segments in the trunk were irregularly shaped and craniofacial muscles were severely reduced or even missing. In the heart, pericardial edema was prevalent in the morphants and heart chambers were elongated and looping was abnormal. These pathologies in muscle and heart were alleviated after reducing the morpholino concentration. However the heart still was abnormal displaying cardiac arrhythmia at later stages of development. Optical recordings of cardiac contractility revealed irregular ventricular contractions with a 2:1, or 3:1 atrial/ventricular conduction ratio, which caused a significant reduction in heart frequency. Recordings of calcium transients with high spatiotemporal resolution using a transgenic calcium indicator line (Tg(cmlc2:gCaMP)s878) and SPIM microscopy confirmed the presence of a severe arrhythmia phenotype. Our results identify popdc2 as a gene important for striated muscle differentiation and cardiac morphogenesis. In addition it is required for the development of the cardiac conduction system. PMID:22290329
Park, Jun I K; Heikhmakhtiar, Aulia Khamas; Kim, Chang Hyun; Kim, Yoo Seok; Choi, Seong Wook; Song, Kwang Soup; Lim, Ki Moo
2018-05-22
Although it is important to analyze the hemodynamic factors related to the right ventricle (RV) after left ventricular assist device (LVAD) implantation, previous studies have focused only on the alteration of the ventricular shape and lack quantitative analysis of the various hemodynamic parameters. Therefore, we quantitatively analyzed various hemodynamic parameters related to the RV under normal, heart failure (HF), and HF incorporated with continuous flow LVAD therapy by using a computational model. In this study, we combined a three-dimensional finite element electromechanical model of ventricles, which is based on human ventricular morphology captured by magnetic resonance imaging (MRI) with a lumped model of the circulatory system and continuous flow LVAD function in order to construct an integrated model of an LVAD implanted-cardiovascular system. To induce systolic dysfunction, the magnitude of the calcium transient function under HF condition was reduced to 70% of the normal value, and the time constant was reduced by 30% of the normal value. Under the HF condition, the left ventricular end systolic pressure decreased, the left ventricular end diastolic pressure increased, and the pressure in the right atrium (RA), RV, and pulmonary artery (PA) increased compared with the normal condition. The LVAD therapy decreased the end-systolic pressure of the LV by 41%, RA by 29%, RV by 53%, and PA by 71%, but increased the right ventricular ejection fraction by 52% and cardiac output by 40%, while the stroke work was reduced by 67% compared with the HF condition without LVAD. The end-systolic ventricular tension and strain decreased with the LVAD treatment. LVAD enhances CO and mechanical unloading of the LV as well as those of the RV and prevents pulmonary hypertension which can be induced by HF.
Atrial fibrillation and sudden cardiac death: catheter-based sensor and mapping system of the heart
NASA Astrophysics Data System (ADS)
Ramasamy, Mouli; Kumar, Prashanth S.; Varadan, Vijay K.
2017-04-01
Ventricular arrhythmias in the heart and the rapid heartbeat of ventricular tachycardia can lead to sudden cardiac death. This is a major health issue worldwide. What is needed is to develop a catheter based sensor and mapping approach which will provide the mechanisms of ventricular arrhythmia, and effectively prevent and treat the same, potentially save life.
Yuan, Yuan; Long, Deyong; Dong, Jianzeng; Tao, Ling; Ma, Changsheng
2017-12-01
We report a case of a patient with right axillary ventricular. Similar congenital anomaly of the right atrium was reported as "right appendage diverticulum or right atrial diverticulum." However, this independent chamber has its own annulus, synchronizes with the right ventricular, and generates large ventricular potential. Under the guidance of the CARTO mapping system (Biosense Webster, Diamond Bar, CA, USA), a right atrioventricular accessory pathway associated with type B Wolff-Parkinson-White syndrome was ablated successfully. This pathway was close to the annulus of the axillary ventricular. The patient remained free of arrhythmia at 1-year follow-up. © 2017 Wiley Periodicals, Inc.
Kishimoto, Satoru; Takewa, Yoshiaki; Tsukiya, Tomonori; Mizuno, Toshihide; Date, Kazuma; Sumikura, Hirohito; Fujii, Yutaka; Ohnuma, Kentaro; Togo, Konomi; Katagiri, Nobumasa; Naito, Noritsugu; Kishimoto, Yuichiro; Nakamura, Yoshinobu; Nishimura, Motonobu; Tatsumi, Eisuke
2018-03-01
The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. We developed a new temporary left ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing. We used three adult goats (body weight, 58-68 kg) to investigate the 30-day performance and hemocompatibility of the newly developed left ventricular assist system, which included the pump, inflow and outflow cannulas, the extracorporeal circuit, and connectors. Hemodynamic, hematologic, and blood chemistry measurements were investigated as well as end-organ effect on necropsy. All goats survived for 30 days in good general condition. The blood pump was operated at a rotational speed of 3000-4500 rpm and a mean pump flow of 3.2 ± 0.6 L min. Excess hemolysis, observed in one goat, was due to the inadequate increase in pump rotational speed in response to drainage insufficiency caused by continuous contact of the inflow cannula tip with the left ventricular septal wall in the early days after surgery. At necropsy, no thrombus was noted in the pump, and no damage caused by mechanical contact was found on the bearing. The newly developed temporary left ventricular assist system using a disposable centrifugal pump with hydrodynamic bearing demonstrated consistent and satisfactory hemodynamic performance and hemocompatibility in the goat model.
Kumar, Saurabh; Fujii, Akira; Kapur, Sunil; Romero, Jorge; Mehta, Nishaki K; Tanigawa, Shinichi; Epstein, Laurence M; Koplan, Bruce A; Michaud, Gregory F; John, Roy M; Stevenson, William G; Tedrow, Usha B
2017-01-01
Catheter ablation can be lifesaving in ventricular tachycardia (VT) storm, but the underlying substrate in patients with storm is not well characterized. We sought to compare the clinical factors, substrate, and outcomes differences in patients with sustained monomorphic VT who present for catheter ablation with VT storm versus those with a nonstorm presentation. Consecutive ischemic (ICM; n = 554) or nonischemic cardiomyopathy patients (NICM; n = 369) with a storm versus nonstorm presentation were studied (ICM storm 186; NICM storm 101). In ICM, storm compared with nonstorm patients had significantly lower left ventricular (LV) ejection fraction (EF), greater number of antiarrhythmic drug (AAD) failures, slower VTs, greater number of scarred LV segments, higher incidence of anterior, septal, and apical endocardial LV scar (all P < 0.05). However, outcomes in follow-up were similar (12-month ventricular arrhythmia [VA]-free survival: 51% vs. 52%, P = 0.6; survival free of death/transplant 75% vs. 87%, P = 0.7). In addition to the above differences, NICM storm patients were also older; however, the extent and distribution of scar was similar except for a higher incidence of lateral endocardial scar in storm patients (P = 0.05). VA-free survival (36% vs. 47%, P = 0.004) and survival free of death/transplant, however, were worse in NICM storm than nonstorm patients (72% vs. 88%, P = 0.001). NICM storm patients had worse VA-free survival than ICM storm patients. There are differences in clinical factors and scar patterns in patients undergoing VT ablation who present with VT storm versus those with a nonstorm presentation. Clinical outcomes are worse in NICM storm patients. © 2016 Wiley Periodicals, Inc.
Smith, Danielle N; Bonagura, John D; Culwell, Nicole M; Schober, Karsten E
2012-03-01
The presence of left ventricular (LV) systolic dysfunction may influence prognosis or therapy in dogs with chronic mitral regurgitation (MR). Assessment of LV function in MR by conventional echocardiography is confounded by altered ventricular loading. Myocardial deformation (strain) imaging might offer more sensitive estimates of LV function in this disease. Prospectively measure myocardial strain in dogs with asymptomatic MR compared to a control group. Forty healthy dogs (3.5-11.5 kg): 20 Controls; 20 dogs with MR and LV remodeling (Stage B2), were evaluated in this study. LV size and function were assessed in a short-axis plane. Segmental radial strain and strain rate and global circumferential strain were measured using a 2D echocardiographic speckle-tracking algorithm (GE EchoPAC). Groups were compared using Bonferroni t-tests. Influences of heart rate and body weight were explored with linear regression. The MR group had significantly greater mean values for heart rate, LV size, and LV systolic function. Specifically, LV diastolic diameter, diastole area, shortening fraction, averaged peak systolic and early diastolic radial strain, global circumferential strain, and averaged radial strain rate were significantly greater in the MR group (p < 0.015 to p < 0.001). Strain was unrelated to weight, but weakly correlated with heart rate. Similar to conventional indices, Stage B2 dogs with MR demonstrate hyperdynamic deformation in the short-axis plane. Short-axis strain variables measured by 2D speckle tracking are greater than for controls of similar age and weight. These results imply either preserved LV systolic function or that LV dysfunction is masked by altered ventricular loading. Copyright © 2012 Elsevier B.V. All rights reserved.
Electrical Substrate Elimination in 135 Consecutive Patients With Brugada Syndrome.
Pappone, Carlo; Brugada, Josep; Vicedomini, Gabriele; Ciconte, Giuseppe; Manguso, Francesco; Saviano, Massimo; Vitale, Raffaele; Cuko, Amarild; Giannelli, Luigi; Calovic, Zarko; Conti, Manuel; Pozzi, Paolo; Natalizia, Andrea; Crisà, Simonetta; Borrelli, Valeria; Brugada, Ramon; Sarquella-Brugada, Georgia; Guazzi, Marco; Frigiola, Alessandro; Menicanti, Lorenzo; Santinelli, Vincenzo
2017-05-01
There is emerging evidence that localization and elimination of abnormal electric activity in the epicardial right ventricular outflow tract may be beneficial in patients with Brugada syndrome. A total of 135 symptomatic Brugada syndrome patients having implantable cardiac defibrillator were enrolled: 63 (group 1) having documented ventricular tachycardia (VT)/ventricular fibrillation (VF) and Brugada syndrome-related symptoms, and 72 (group 2) having inducible VT/VF without ECG documentation at the time of symptoms. About 27 patients of group 1 experienced multiple implantable cardiac defibrillator shocks for recurrent VT/VF episodes. Three-dimensional maps before and after ajmaline determined the arrhythmogenic electrophysiological substrate (AES) as characterized by prolonged fragmented ventricular potentials. Primary end point was identification and elimination of AES leading to ECG pattern normalization and VT/VF noninducibility. Extensive areas of AES were found in the right ventricle epicardium, which were wider in group 1 ( P =0.007). AES increased after ajmaline in both groups ( P <0.001) and was larger in men ( P =0.008). The increase of type-1 ST-segment elevation correlated with AES expansion ( r =0.682, P <0.001). Radiofrequency ablation eliminated AES leading to ECG normalization and VT/VF noninducibility in all patients. During a median follow-up of 10 months, the ECG remained normal even after ajmaline in all except 2 patients who underwent a repeated effective procedure for recurrent VF. In Brugada syndrome, AES is commonly located in the right ventricle epicardium and ajmaline exposes its extent and distribution, which is correlated with the degree of coved ST-elevation. AES elimination by radiofrequency ablation results in ECG normalization and VT/VF noninducibility. Substrate-based ablation is effective in potentially eliminating the arrhythmic consequences of this genetic disease. URL: https://clinicaltrials.gov. Unique identifier: NCT02641431. © 2017 American Heart Association, Inc.
Bonetti, F; Margonato, A; Mailhac, A; Vicedomini, G; Cianflone, D; Scarpazza, P; Chierchia, S L
1990-05-01
In patients with ischemic heart disease and arrhythmias, selection of antiarrhythmic treatment is often difficult as it is hard to separate "primary" from ischemic arrhythmias. We studied 20 patients with ischemic heart disease, who developed ventricular arrhythmias consistently during exercise test. Exercise test was performed twice during infusion of placebo and then during intravenous administration of nitroglycerin, titrated to reduce systolic blood pressure by 10 mmHg. Exercise duration was 7.8 +/- 1.7 and 7.9 +/- 1.5 min, in the 2 placebo tests (NS). Angina developed in 5 patients and ischemic ST changes in 10. With nitroglycerin exercise duration increased to 8.4 +/- 20 min (p less than 0.05), diagnostic ST segment depression was observed in 2 patients and only 1 had angina. In all 20 patients, ventricular arrhythmias were consistently present during both tests on placebo, that were markedly reduced by nitroglycerin. In fact, ventricular ectopic beats were 455 (mean 35.8 +/- 16.8) and 418 (mean 34.4 +/- 11.1) in the 2 exercise tests with placebo, and 11 during nitroglycerin infusion (mean 0.6 +/- 0.1; p less than 0.001). Couplets were 28 and 29 during placebo (NS) and 0 during nitroglycerin (p less than 0.001). Ventricular tachycardia was present in 6 and 8 patients during placebo but in none during nitroglycerin (p less than 0.001). Reduction of exercise-induced arrhythmias was maintained during chronic treatment with oral vasodilators. Prevention of exercise-related arrhythmias by nitroglycerin infusion appears a good indicator of their ischemic origin and may provide valuable information for long-term profilaxis with oral vasodilators, then avoiding the use of antiarrhythmic agents and their potential side effects.
Furuta, Akihiro; Onishi, Hideo; Amijima, Hizuru
2018-06-01
This study aimed to evaluate the effect of ventricular enlargement on the specific binding ratio (SBR) and to validate the cerebrospinal fluid (CSF)-Mask algorithm for quantitative SBR assessment of 123 I-FP-CIT single-photon emission computed tomography (SPECT) images with the use of a 3D-striatum digital brain (SDB) phantom. Ventricular enlargement was simulated by three-dimensional extensions in a 3D-SDB phantom comprising segments representing the striatum, ventricle, brain parenchyma, and skull bone. The Evans Index (EI) was measured in 3D-SDB phantom images of an enlarged ventricle. Projection data sets were generated from the 3D-SDB phantoms with blurring, scatter, and attenuation. Images were reconstructed using the ordered subset expectation maximization (OSEM) algorithm and corrected for attenuation, scatter, and resolution recovery. We bundled DaTView (Southampton method) with the CSF-Mask processing software for SBR. We assessed SBR with the use of various coefficients (f factor) of the CSF-Mask. Specific binding ratios of 1, 2, 3, 4, and 5 corresponded to SDB phantom simulations with true values. Measured SBRs > 50% that were underestimated with EI increased compared with the true SBR and this trend was outstanding at low SBR. The CSF-Mask improved 20% underestimates and brought the measured SBR closer to the true values at an f factor of 1.0 despite an increase in EI. We connected the linear regression function (y = - 3.53x + 1.95; r = 0.95) with the EI and f factor using root-mean-square error. Processing with CSF-Mask generates accurate quantitative SBR from dopamine transporter SPECT images of patients with ventricular enlargement.
Ischemic Ventricular Tachycardia Presenting as a Narrow Complex Tachycardia
Page, Stephen P; Watts, Troy; Yeo, Wee Tiong; Mehul, Dhinoja
2014-01-01
This report describes a patient presenting with a narrow complex tachycardia in the context of prior myocardial infarction and impaired ventricular function. Electrophysiological studies confirmed ventricular tachycardia and activation and entrainment mapping demonstrated a critical isthmus within an area of scar involving the His-Purkinje system accounting for the narrow QRS morphology. This very rare case shares some similarities with upper septal ventricular tachycardia seen in patients with structurally normal hearts, but to our knowledge has not been seen previously in patients with ischemic heart disease. PMID:25057222
Israel, Carsten W; Ekosso-Ejangue, Lucy; Sheta, Mohamed-Karim
2015-09-01
The key to a successful analysis of a pacemaker electrocardiogram (ECG) is the application of the systematic approach used for any other ECG without a pacemaker: analysis of (1) basic rhythm and rate, (2) QRS axis, (3) PQ, QRS and QT intervals, (4) morphology of P waves, QRS, ST segments and T(U) waves and (5) the presence of arrhythmias. If only the most obvious abnormality of a pacemaker ECG is considered, wrong conclusions can easily be drawn. If a systematic approach is skipped it may be overlooked that e.g. atrial pacing is ineffective, the left ventricle is paced instead of the right ventricle, pacing competes with intrinsic conduction or that the atrioventricular (AV) conduction time is programmed too long. Apart from this analysis, a pacemaker ECG which is not clear should be checked for the presence of arrhythmias (e.g. atrial fibrillation, atrial flutter, junctional escape rhythm and endless loop tachycardia), pacemaker malfunction (e.g. atrial or ventricular undersensing or oversensing, atrial or ventricular loss of capture) and activity of specific pacing algorithms, such as automatic mode switching, rate adaptation, AV delay modifying algorithms, reaction to premature ventricular contractions (PVC), safety window pacing, hysteresis and noise mode. A systematic analysis of the pacemaker ECG almost always allows a probable diagnosis of arrhythmias and malfunctions to be made, which can be confirmed by pacemaker control and can often be corrected at the touch of the right button to the patient's benefit.
Patient-specific models of cardiac biomechanics
NASA Astrophysics Data System (ADS)
Krishnamurthy, Adarsh; Villongco, Christopher T.; Chuang, Joyce; Frank, Lawrence R.; Nigam, Vishal; Belezzuoli, Ernest; Stark, Paul; Krummen, David E.; Narayan, Sanjiv; Omens, Jeffrey H.; McCulloch, Andrew D.; Kerckhoffs, Roy C. P.
2013-07-01
Patient-specific models of cardiac function have the potential to improve diagnosis and management of heart disease by integrating medical images with heterogeneous clinical measurements subject to constraints imposed by physical first principles and prior experimental knowledge. We describe new methods for creating three-dimensional patient-specific models of ventricular biomechanics in the failing heart. Three-dimensional bi-ventricular geometry is segmented from cardiac CT images at end-diastole from patients with heart failure. Human myofiber and sheet architecture is modeled using eigenvectors computed from diffusion tensor MR images from an isolated, fixed human organ-donor heart and transformed to the patient-specific geometric model using large deformation diffeomorphic mapping. Semi-automated methods were developed for optimizing the passive material properties while simultaneously computing the unloaded reference geometry of the ventricles for stress analysis. Material properties of active cardiac muscle contraction were optimized to match ventricular pressures measured by cardiac catheterization, and parameters of a lumped-parameter closed-loop model of the circulation were estimated with a circulatory adaptation algorithm making use of information derived from echocardiography. These components were then integrated to create a multi-scale model of the patient-specific heart. These methods were tested in five heart failure patients from the San Diego Veteran's Affairs Medical Center who gave informed consent. The simulation results showed good agreement with measured echocardiographic and global functional parameters such as ejection fraction and peak cavity pressures.
Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng
2012-11-01
Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective.
Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng
2012-01-01
OBJECTIVE: Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS: We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. RESULTS: Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. CONCLUSION: Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective. PMID:23184204
Local heterogeneities in cardiac systems suppress turbulence by generating multi-armed rotors
NASA Astrophysics Data System (ADS)
Zhang, Zhihui; Steinbock, Oliver
2016-05-01
Ventricular fibrillation is an extremely dangerous cardiac arrhythmia that is linked to rotating waves of electric activity and chaotically moving vortex lines. These filaments can pin to insulating, cylindrical heterogeneities which swiftly become the new rotation backbone of the local wave field. For thin cylinders, the stabilized rotation is sufficiently fast to repel the free segments of the turbulent filament tangle and annihilate them at the system boundaries. The resulting global wave pattern is periodic and highly ordered. Our cardiac simulations show that also thicker cylinders can establish analogous forms of tachycardia. This process occurs through the spontaneous formation of pinned multi-armed vortices. The observed number of wave arms N depends on the cylinder radius and is associated to stability windows that for N = 2, 3 partially overlap. For N = 1, 2, we find a small gap in which the turbulence is removed but the pinned rotor shows complex temporal dynamics. The relevance of our findings to human cardiology are discussed in the context of vortex pinning to more complex-shaped anatomical features and remodeled myocardium.
Aggarwal, Sourabh; Xie, Feng; High, Robin; Pavlides, Gregory; Porter, Thomas R
2018-06-01
Although microvascular flow abnormalities have been observed following epicardial recanalization in acute ST-segment elevation myocardial infarction (STEMI), the prevalence and severity of these abnormalities in the current era of rapid percutaneous coronary intervention (PCI) has not been evaluated. The objective of this study was to assess microvascular perfusion (MVP) following successful primary PCI in patients with STEMI and how it affects clinical outcome. In this single-center, retrospective study, 170 patients who successfully underwent emergent PCI for STEMI were assessed using real-time myocardial contrast echocardiography using a continuous infusion of intravenous commercial microbubbles (3% Definity). Three patterns of myocardial contrast replenishment were observed following intermittent high-mechanical index impulses: infarct zone replenishment within 4 sec (normal MVP), delays in contrast replenishment but normal plateau intensity (delayed MVP [dMVP]), and both delays in replenishment and reduced plateau intensity (microvascular obstruction [MVO]). Changes in left ventricular ejection fraction at 6 months and clinical event rate at 12 months (death, recurrent infarction, need for defibrillator placement, or heart failure admission) were compared. Normal MVP was seen in 62 patients (36%), dMVP in 49 (29%), and MVO in 59 (35%). Left anterior descending coronary artery infarct location was the only parameter independently associated with dMVP or MVO, independent of age, cardiac risk factors, door-to-dilation time, pre-PCI Thrombolysis In Myocardial Infarction flow grade, and thrombus burden. A dMVP pattern had a similar reduction in left ventricular ejection fraction as MVO at hospital discharge but had recovery of left ventricular ejection fraction at 6 months and a greater than fourfold lower event rate than the MVO group (P < .001). MVO and dMVP are frequently seen following contemporary successful PCI for STEMI, especially following left anterior descending coronary artery infarction. Despite a similar area at risk, a dMVP pattern has better functional recovery and clinical outcome than MVO. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Singh, Gautam K.; Cupps, Brian; Pasque, Michael; Woodard, Pamela K.; Holland, Mark R.; Ludomirsky, Achiau
2013-01-01
Background Myocardial strain is a sensitive measure of ventricular systolic function. Two-dimensional speckle-tracking echocardiography (2DSE) is an angle-independent method for strain measurement but has not been validated in pediatric subjects. We evaluated the accuracy and reproducibility of 2DSE-measured strain against reference tagged MRI-measured strain in pediatric subjects with normal hearts and those with single ventricle (SV) of left ventricle (LV) morphology s/p Fontan procedure. Methods Peak systolic circumferential (CS) and longitudinal (LS) strains in segments (n = 16) of LVs in age and BSA matched 20 healthy and 12 pediatric subjects with tricuspid atresia s/p Fontan procedure were measured by 2DSE and tagged MRI. Average (global) and regional segmental strains measured by two methods were compared using Spearman and Bland-Altman analyses. Results 2DSE and tagged MRI measured global strains demonstrated close agreements, which were better for LS than CS and in normal LVs than in SVs (95% limits of agreement: +0.0% to +3.12%, −2.48 % to +1.08%, −4.6% to +1.8% and −3.6% to +1.8% respectively). There was variability in agreement between regional strains with wider limits in apical than in basal regions in normal LVs and heterogeneous in SVs. The strain values were significantly (p < 0.05) higher in normal LVs than in SVs except for basal LSs, which were similar in both cohorts. The regional strains in normal LVs demonstrated an apico-basal magnitude gradient whereas SVs showed heterogeneity. The reproducibility was the most robust for images obtained with frame rates between 60 and 90 frame/sec; global LS in both cohorts; and basal strains in normal LVs. Conclusions 2DSE-measured strains agree with MRI-measured strain globally but vary regionally particularly in SVs. Global strain may be more robust tool for the cardiac function evaluation than regional strain in SV physiology. The reliability of 2DSE measured strain is affected by the frame rate, nature of strain, and ventricular geometry. PMID:20850945
Hemodynamics on abrupt stoppage of centrifugal pumps during left ventricular assist.
Kono, S; Nishimura, K; Nishina, T; Akamatsu, T; Komeda, M
2000-01-01
A magnetically suspended centrifugal pump (MSCP), developed for long-term ventricular assist, is reliable and durable because it has no shaft or seal. However, with nonvalve pumps such as a MSCP, regurgitation occurs when they accidentally stop without cannula clamping. We investigated the hemodynamics during temporary stoppage of a MSCP being used as a left ventricular assist system (LVAS), comparing two inflow cannulation sites. In four sheep (weight, 35-45 kg), microspheres were injected into the left main coronary artery to induce heart failure. An outflow cannula was sutured onto the descending aorta, and two inflow cannulae were inserted into the left atrium and the left ventricle. The MSCP was stopped with both the left ventricular cannula and left atrial cannula clamped, and the hemodynamics and P-V loops were recorded. Each cannula was then unclamped in order, and similar parameters were recorded. LVEDP increased at unclamping of the left ventricular cannula (ULVC), and rose further at unclamping of the left atrial cannula (ULAC). Aortic pressure did not change at ULVC, but decreased at ULAC. The effective systemic flow that subtracted the regurgitant flow through the MSCP from left ventricular output was half at ULVC and almost 0 at ULAC. When stopping centrifugal pumps without circuit clamping, hemodynamic deterioration is less at ULVC than at ULAC. This finding suggests that left ventricular inflow cannulation is recommended to allow more time in emergency situations.
Scandura, Salvatore; Dipasqua, Fabio; Gargiulo, Giuseppe; Capodanno, Davide; Caggegi, Anna; Grasso, Carmelo; Mangiafico, Sarah; Pistritto, Anna Maria; Immè, Sebastiano; Chiarandà, Marta; Ministeri, Margherita; Ronsivalle, Giuseppe; Cannata, Stefano; Arcidiacono, Antonio Andrea; Capranzano, Piera; Tamburino, Corrado
2016-11-01
To appraise the early effect of percutaneous mitral valve repair with the MitraClip system on myocardial function using real-time three-dimensional speckle-tracking echocardiography (3D-STE). Consecutive patients with moderate-to-severe or severe mitral regurgitation, undergoing mitral valve repair with the MitraClip system, were prospectively evaluated during the peri-procedural workout and follow-up. Left ventricular deformation was evaluated by a two-dimensional and 3D speckle-tracking analysis. 3D-STE acquisitions were elaborated obtaining real-time 3D global longitudinal strain evaluation, and by appraising both volumetric and hemodynamic parameters (i.e. left ventricular end-diastolic volume, left ventricular end-systolic volume, left ventricular ejection fraction, cardiac output, and stroke volume). In all, 30 patients were included. At 1-month follow-up, 3D-STE analysis revealed no changes in left ventricular end-diastolic volume (162.6 ± 73.7 ml at baseline vs. 159.8 ± 64.5 ml at 1-month follow-up; P = 0.63) and a downward trend in left ventricular end-systolic volume (104.7 ± 52.0 vs. 100.1 ± 50.4 ml, respectively; P = 0.06). Left ventricular ejection fraction did not significantly increase (38.1 ± 11.3% at baseline vs. 39.4 ± 11.0% at 1-month follow-up; P = 0.20). No significant changes were reported in cardiac output (4.3 ± 2.0 l/min at baseline vs. 4.0 ± 1.5 l/min at follow-up; P = 0.377) and in stroke volume (59.5 ± 25.5 ml at baseline vs. 59.9 ± 20.7 ml at follow-up; P = 0.867). On the contrary, left ventricular deformation capability significantly improved, with the real-time 3D global longitudinal strain value changing from -9.8 ± 4.1% at baseline to -11.0 ± 4.4% at follow-up (P = 0.018). Accurately assessing myocardial function by the use of 3D-STE, this study reported irrelevant early changes in left ventricular size, but a positive effect on left ventricular deformation capability following mitral valve repair with the MitraClip system. These preliminary results need to be confirmed in larger series and extended to long-term follow-up.
The normal variants in the left bundle branch system.
Elizari, M V
This article reviewed the main anatomic and physiopathological aspects of the left bundle branch from its origin in the His bundle and its intraventricular distribution on the left endocardial surface. The results are based on the relevant literature and on personal observations executed on 206 hearts distributed as follows: 67 dogs, 60 humans, 45 sheep, 22 pigs, 10 cows, 2 monkeys, 1 guanaco, and 1 sea lion. The main anatomical features of the His-Purkinje conducting system may be summarized as follows: The bundle of His is composed by two segments: the penetrating and branching portions. LBB originates in the branching portion located underneath the membranous septum. There is no true bifurcation of the bundle of His in a human heart. Short after its origin the LBB gives rise to its two main fascicles, anterior and posterior, both heading the anterior and posterior papillary muscles, respectively. The anterior division is thinner and longer than the posterior one. The RBB and the most anterior fibers of the LBB arise at the end of the branching portion. In some cases a well-defined left septal fascicle can be identified, usually arising from the posterior division. Each division gives off small fibers and false tendons crossing the left ventricular cavity connecting the papillary between them or the papillary muscles with the septal surface. From each division of the LBB, their corresponding Purkinje networks emerge covering the subendocardium of the septum and the free wall of the left ventricles. There are critical relationships of the proximal segments of the His-Purkinje system with the surrounding cardiac structures whose pathologic processes may damage the conducting tissue. Copyright © 2017 Elsevier Inc. All rights reserved.
Forman, Mervyn B; Jackson, Edwin K
2007-11-01
High risk ST segment elevation myocardial infarction (STEMI) patients undergoing reperfusion therapy continue to exhibit significant morbidity and mortality due in part to myocardial reperfusion injury. Importantly, preclinical studies demonstrate that progressive microcirculatory failure (the "no-reflow" phenomenon) contributes significantly to myocardial reperfusion injury. Diagnostic techniques to measure tissue perfusion have validated this concept in humans, and it is now clear that abnormal tissue perfusion occurs frequently in STEMI patients undergoing reperfusion therapy. Moreover, because tissue perfusion correlates poorly with epicardial blood flow (TIMI flow grade), clinical studies show that tissue perfusion is an independent predictor of early and late mortality in STEMI patients and is associated with infarct size, ventricular function, CHF and ventricular arrhythmias. The mechanisms responsible for abnormal tissue perfusion are multifactorial and include both mechanical obstruction and vasoconstrictor humoral factors. Adenosine, an endogenous nucleoside, maintains microcirculatory flow following reperfusion by activating four well-characterized extracellular receptors. Because activation of adenosine receptors attenuates the mechanical and functional mechanisms leading to the "no reflow" phenomenon and activates other cardioprotective pathways as well, it is not surprising that both experimental and clinical studies show striking myocardial salvage with intravenous infusions of adenosine administered in the peri-reperfusion period. For example, a post hoc analysis of the AMISTAD II trial indicates a significant reduction in 1 and 6-month mortality in STEMI patients undergoing reperfusion therapy who are treated with adenosine within 3 hours of symptoms. In conclusion, adenosine's numerous cardioprotective effects, including attenuation of the "no-reflow" phenomenon, support its use in high risk STEMI undergoing reperfusion.
Mielczarek, Agnieszka; Kasprzak, Jarosław Damian; Marcinkiewicz, Andrzej; Kurpesa, Małgorzata; Uznańska-Loch, Barbara; Wierzbowska-Drabik, Karina
2015-01-01
Takotsubo cardiomiopathy (TTC) (known also as "ampulla cardiomyopathy," "apical ballooning" or "broken heart syndrome") is connected with a temporary systolic left ventricular dysfunction without the culprit coronary lesion. Takotsubo cardiomyopathy was first described in 1990 in Japan after octopus trapping pot with a round bottom and narrow neck similar in shape to left ventriculogram in TTC patients. The occurrence of TTC is usually precipitated by a stressful event with a clinical presentation mimicking myocardial infarction: chest pain, ST-T segment elevation or T-wave inversion, a rise in cardiac troponin, and contractility abnormalities in echocardiography. A left ventricular dysfunction is transient and improves within a few weeks. Takotsubo cardiomyopathy typically occurs in postmenopausal women and the postulated mechanism is catecholamine overstimulation. Moreover, the distribution of contractility impairments usually does not correspond with typical region supplied by a single coronary artery. Therefore, the assessment of regional pattern of systolic dysfunction with speckle-tracking echocardiography and automated function imaging (AFI) technique may be important in diagnosis of TTC and may improve our insight into its patophysiology. We described a 55-year-old female teacher with TTC diagnosed after acute psychological stress in workplace. The provoking factor related with occupational stress and pattern of contraction abnormalities documented with AFI technique including basal segments of left ventricle make this case atypical. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
NASA Astrophysics Data System (ADS)
Teo, S.-K.; Wong, S. T.; Tan, M. L.; Su, Y.; Zhong, L.; Tan, Ru-San
2015-03-01
After surgical repair for Tetralogy of Fallot (TOF), most patients experience long-term complications as the right ventricle (RV) undergoes progressive remodeling that eventually affect heart functions. Thus, post-repair surgery is required to prevent further deterioration of RV functions that may result in malignant ventricular arrhythmias and mortality. The timing of such post-repair surgery therefore depends crucially on the quantitative assessment of the RV functions. Current clinical indices for such functional assessment measure global properties such as RV volumes and ejection fraction. However, these indices are less than ideal as regional variations and anomalies are obscured. Therefore, we sought to (i) develop a quantitative method to assess RV regional function using regional ejection fraction (REF) based on a 13-segment model, and (ii) evaluate the effectiveness of REF in discriminating 6 repaired TOF patients and 6 normal control based on cardiac magnetic resonance (CMR) imaging. We observed that the REF for the individual segments in the patient group is significantly lower compared to the control group (P < 0.05 using a 2-tail student t-test). In addition, we also observed that the aggregated REF at the basal, mid-cavity and apical regions for the patient group is significantly lower compared to the control group (P < 0.001 using a 2-tail student t-test). The results suggest that REF could potentially be used as a quantitative index for assessing RV regional functions. The computational time per data set is approximately 60 seconds, which demonstrates our method's clinical potential as a real-time cardiac assessment tool.
Romero, Daniel; Ringborn, Michael; Demidova, Marina; Koul, Sasha; Laguna, Pablo; Platonov, Pyotr G; Pueyo, Esther
2012-12-01
In this study, several electrocardiogram (ECG)-derived indices corresponding to both ventricular depolarization and repolarization were evaluated during acute myocardial ischemia in an experimental model of myocardial infarction produced by 40 min coronary balloon inflation in 13 pigs. Significant changes were rapidly observed from minute 4 after the start of coronary occlusion, achieving their maximum values between 11 and 22 min for depolarization and between 9 and 12 min for repolarization indices, respectively. Subsequently, these maximum changes started to decrease during the latter part of the occlusion. Depolarization changes associated with the second half of the QRS complex showed a significant but inverse correlation with the myocardium at risk (MaR) estimated by scintigraphic images. The correlation between MaR and changes of the downward slope of the QRS complex, [Formula: see text], evaluated at the two more relevant peaks observed during the occlusion, was r = -0.75, p < 0.01 and r = -0.79, p < 0.01 for the positive and negative deflections observed in [Formula: see text], temporal evolution, respectively. Repolarization changes, analyzed by evaluation of ST segment elevation at the main observed positive peak, also showed negative, however non-significant correlation with MaR: r = -0.34, p = 0.28. Our results suggest that changes evaluated in the latter part of the depolarization, such as those described by [Formula: see text], which are influenced by R-wave amplitude, QRS width and ST level variations simultaneously, correlate better with the amount of ischemia than other indices evaluated in the earlier part of depolarization or during the ST segment.
Efficacy and safety of dextrose-insulin in unmasking non-diagnostic Brugada ECG patterns.
Velázquez-Rodríguez, Enrique; Rodríguez-Piña, Horacio; Pacheco-Bouthillier, Alex; Jiménez-Cruz, Marcelo Paz
Typical diagnostic, coved-type 1, Brugada ECG patterns fluctuate spontaneously over time with a high proportion of non-diagnostic ECG patterns. Insulin modulates ion transport mechanisms and causes hyperpolarization of the resting potential. We report our experience with unmasking J-ST changes in response to a dextrose-insulin test. Nine patients, mean age 40.5±19.4years (range: 15-65years), presented initially with a non-diagnostic ECG pattern, which was suggestive of Brugada syndrome (group I). They were compared with 10 patients with normal ECG patterns (group II). Participants received an infusion of 50g of 50% dextrose, followed by 10IU of intravenous regular insulin. Positive changes were defined by conversion to a diagnostic ECG pattern. The dextrose-insulin test was positive in six of seven (85.7%) patients (kappa 0.79, p=0.02) that was confirmed with a pharmacologic test (kappa 1, p=0.003). One had an inconclusive test, and two with a negative test had an early repolarization ECG pattern. All subjects in group II had a negative test (p<0.01). The maximum changes of the J-ST segment were observed 41.3±31.4minutes (range 3-90minutes) after dextrose-insulin infusion. One patient had monomorphic ventricular bigeminy without spontaneous or induced ventricular fibrillation. Changes in J-ST segment in the Brugada syndrome are influenced by glucose-insulin, and this report reproduces and supports the efficacy and safety of this metabolic test in the differential diagnosis of patients with non-diagnostic ECG patterns. Copyright © 2016 Elsevier Inc. All rights reserved.
Ventricular efficiency in pregnant women with congenital heart disease.
Muneuchi, Jun; Yamasaki, Keiko; Watanabe, Mamie; Fukumitsu, Azusa; Kawakami, Takeshi; Nakahara, Hiromasa; Joo, Kunitaka
2018-06-15
Pregnant women with congenital heart disease (CHD) are at risk of cardiovascular events during pregnancy as well as postpartum. The aim of our study is to address the feasibility of echocardiography-derived ventricular-arterial coupling during pregnancy and postpartum among women with CHD. In 31 pregnant women with CHD, we performed serial echocardiography at the first and third trimesters, early and late postpartum. The indices of contractility (single-beat determined end-systolic elastance, Ees ab ) and afterload (effective arterial elastance, Ea) were approximated on the basis of the systemic blood pressure and systemic ventricular volume. The ratio of stroke work and pressure-volume area (SW/PVA) representing ventricular efficiency was also calculated. Age at the delivery was 28 (24-31) years. ZAHARA score was 0.75 (0.75-1.50). Gestational age and birth weight of newborns were 38 (37-39) weeks and 2.73 (2.42-2.92) kg, respectively. Heart rate, systemic ventricular end-diastolic volume and stroke volume significantly increased from the first trimester to the third trimester and reversed postpartum to the values of the first trimester. Ees ab and Ea significantly decreased from the first trimester to the third trimester (Ees ab ; 4.90 [2.86-7.14] vs 3.41 [2.53-4.61] mm Hg/ml, p = 0.0001, Ea; 2.83 [1.74-3.30] vs 2.18 [1.67-2.68] mm Hg/ml, p = 0.0012), and reversed early postpartum parallelly. Ejection fraction and SW/PVA remained unchanged throughout pregnancy and postpartum. Echocardiography-derived ventricular-arterial coupling is feasible to understand ventricular function in pregnant women with CHD. Copyright © 2018 Elsevier B.V. All rights reserved.
Interactive visualization for scar transmurality in cardiac resynchronization therapy
NASA Astrophysics Data System (ADS)
Reiml, Sabrina; Toth, Daniel; Panayiotou, Maria; Fahn, Bernhard; Karim, Rashed; Behar, Jonathan M.; Rinaldi, Christopher A.; Razavi, Reza; Rhode, Kawal S.; Brost, Alexander; Mountney, Peter
2016-03-01
Heart failure is a serious disease affecting about 23 million people worldwide. Cardiac resynchronization therapy is used to treat patients suffering from symptomatic heart failure. However, 30% to 50% of patients have limited clinical benefit. One of the main causes is suboptimal placement of the left ventricular lead. Pacing in areas of myocardial scar correlates with poor clinical outcomes. Therefore precise knowledge of the individual patient's scar characteristics is critical for delivering tailored treatments capable of improving response rates. Current research methods for scar assessment either map information to an alternative non-anatomical coordinate system or they use the image coordinate system but lose critical information about scar extent and scar distribution. This paper proposes two interactive methods for visualizing relevant scar information. A 2-D slice based approach with a scar mask overlaid on a 16 segment heart model and a 3-D layered mesh visualization which allows physicians to scroll through layers of scar from endocardium to epicardium. These complementary methods enable physicians to evaluate scar location and transmurality during planning and guidance. Six physicians evaluated the proposed system by identifying target regions for lead placement. With the proposed method more target regions could be identified.
Mulpuru, Siva K; Cha, Yong-Mei; Asirvatham, Samuel J
2016-11-01
Right ventricular apical pacing is associated with an increased incidence of heart failure, atrial fibrillation, and overall mortality. As a result, pacing the ventricles in a manner that closely mimics normal AV conduction with an intact His-Purkinje system has been explored. Recently, the sustainable benefits of selective His-bundle stimulation have been demonstrated and proposed as the preferred method of ventricular stimulation for appropriate patients. Ideally, conduction system pacing should be selective without myocardial capture, overcome distal bundle branch block when present, and not compromise tricuspid valve function. Contemporary literature on conduction system pacing is confusing largely because of inconsistent terminology and, at times, anatomically inaccurate terms used interchangeably for nonsynonymous anatomic sites. In this review, we discuss the functional anatomy of AV conduction access with specific emphasis on terminology, relationship to the membranous septum, tricuspid valve tissue, and proximity to atrial or ventricular myocardium. The potential benefits of each specific site as well as associated unique difficulties with those sites are described. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Cardiovascular studies using the chimpanzee (Pan troglodytes)
NASA Technical Reports Server (NTRS)
Hinds, J. E.; Cothran, L. N.; Hawthorne, E. W.
1977-01-01
Despite the phylogenetic similarities between chimpanzees and man, there exists a paucity of reliable data on normal cardiovascular function and the physiological responses of the system to standard interventions. Totally implanted biotelemetry systems or hardwire analog techniques were used to examine the maximum number of cardiovascular variables which could be simultaneously monitored without significantly altering the system's performance. This was performed in order to acquire base-line data not previously obtained in this species, to determine cardiovascular response to specific forcing functions such as ventricular pacing, drug infusions, and lower body negative pressure. A cardiovascular function profile protocol was developed in order to adjust independently the three major factors which modify ventricular performance, namely, left ventricular performance, left ventricular preload, afterload, and contractility. Cardiac pacing at three levels above the ambient rate was used to adjust end diastolic volume (preload). Three concentrations of angiotensin were infused continuously to evaluate afterload in a stepwide fashion. A continuous infusion of dobutamine was administered to raise the manifest contractile state of the heart.
Kobayashi, Shinya; Ishikawa, Tatsuya; Mutoh, Tatsushi; Hikichi, Kentaro; Suzuki, Akifumi
2012-01-01
Background: Surgical placement of a ventriculoperitoneal shunt (VPS) is the main strategy to manage hydrocephalus. However, the failure rate associated with placement of ventricular catheters remains high. Methods: A hybrid operating room, equipped with a flat-panel detector digital subtraction angiography system containing C-arm cone-beam computed tomography (CB-CT) imaging, has recently been developed and utilized to assist neurosurgical procedures. We have developed a novel technique using intraoperative fluoroscopy and a C-arm CB-CT system to facilitate accurate placement of a VPS. Results: Using this novel technique, 39 consecutive ventricular catheters were placed accurately, and no ventricular catheter failures were experienced during the follow-up period. Only two patients experienced obstruction of the VPS, both of which occurred in the extracranial portion of the shunt system. Conclusion: Surgical placement of a VPS assisted by flat panel detector CT-guided real-time fluoroscopy enabled accurate placement of ventricular catheters and was associated with a decreased need for shunt revision. PMID:23226605
Sasikumar, Navaneetha; Krishna Manohar, Soman R; Philip, Saji; Cherian, Kottoorathu Mammen; Suresh Kumar, Raghavannair
2013-08-01
A 20 year-old male was diagnosed to have Ebstein's anomaly with severe right ventricular dysfunction. He was taken up for 1.5 ventricle repair. Post procedure, there was difficulty in weaning from cardiopulmonary bypass due to progressive right ventricular dilatation compromising the systemic output. An atrial septectomy did not help. Progressive right ventricular dilatation compressing the left ventricle, demonstrated on transoesophageal echocardiogram, prompted us to perform a right ventricular exclusion and univentricular palliation. The patient was successfully weaned off cardiopulmonary bypass and had a smooth postoperative recovery. Judicious use of right ventricular exclusion and univentricular palliation could be an effective bailout strategy in difficult surgical scenarios in Ebstein's anomaly. Copyright © 2012 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Perioperative Assessment of Myocardial Deformation
Duncan, Andra E.; Alfirevic, Andrej; Sessler, Daniel I.; Popovic, Zoran B.; Thomas, James D.
2014-01-01
Evaluation of left ventricular performance improves risk assessment and guides anesthetic decisions. However, the most common echocardiographic measure of myocardial function, the left ventricular ejection fraction (LVEF), has important limitations. LVEF is limited by subjective interpretation which reduces accuracy and reproducibility, and LVEF assesses global function without characterizing regional myocardial abnormalities. An alternative objective echocardiographic measure of myocardial function is thus needed. Myocardial deformation analysis, which performs quantitative assessment of global and regional myocardial function, may be useful for perioperative care of surgical patients. Myocardial deformation analysis evaluates left ventricular mechanics by quantifying strain and strain rate. Strain describes percent change in myocardial length in the longitudinal (from base to apex) and circumferential (encircling the short-axis of the ventricle) direction and change in thickness in the radial direction. Segmental strain describes regional myocardial function. Strain is a negative number when the ventricle shortens longitudinally or circumferentially and is positive with radial thickening. Reference values for normal longitudinal strain from a recent meta-analysis using transthoracic echocardiography are (mean ± SD) −19.7 ± 0.4%, while radial and circumferential strain are 47.3 ± 1.9 and −23.3 ± 0.7%, respectively. The speed of myocardial deformation is also important and is characterized by strain rate. Longitudinal systolic strain rate in healthy subjects averages −1.10 ± 0.16 sec−1. Assessment of myocardial deformation requires consideration of both strain (change in deformation), which correlates with LVEF, and strain rate (speed of deformation), which correlates with rate of rise of left ventricular pressure (dP/dt). Myocardial deformation analysis also evaluates ventricular relaxation, twist, and untwist, providing new and noninvasive methods to assess components of myocardial systolic and diastolic function. Myocardial deformation analysis is based on either Doppler or a non-Doppler technique, called speckle-tracking echocardiography. Myocardial deformation analysis provides quantitative measures of global and regional myocardial function for use in the perioperative care of the surgical patient. For example, coronary graft occlusion after coronary artery bypass grafting is detected by an acute reduction in strain in the affected coronary artery territory. In addition, assessment of left ventricular mechanics detects underlying myocardial pathology before abnormalities become apparent on conventional echocardiography. Certainly, patients with aortic regurgitation demonstrate reduced longitudinal strain before reduction in LVEF occurs, which allows detection of subclinical left ventricular dysfunction and predicts increased risk for heart failure and impaired myocardial function after surgical repair. In this review we describe the principles, techniques, and clinical application of myocardial deformation analysis. PMID:24557101
Initial experience with remote magnetic navigation for left ventricular lead placement.
Mischke, Karl; Knackstedt, Christian; Schmid, Michael; Hatam, Nima; Becker, Michael; Spillner, Jan; Fache, Kerstin; Kelm, Malte; Schauerte, Patrick
2009-08-01
A novel magnetic navigation system allows remote steering of guidewires and catheters. This system may be used for left ventricular lead placement for cardiac resynchronization therapy (CRT). We sought to evaluate the feasibility and safety of magnetic guidewire navigation for CRT procedures. 123 consecutive patients underwent CRT implantation/revision procedures (including pacemaker upgrades in n=22 and left ventricular lead placement after dislocation in n=4 patients). Left ventricular lead placement in a coronary sinus side branch was performed either conventionally or using magnetic navigation. The magnetic navigation system (Niobe) consists of two permanent magnets creating a steerable magnetic field. Guidewires with integrated magnets align to the magnetic field and were used for over-the-wire implantation of pacemaker leads in the coronary sinus. Patients were assigned to conventional (n=93) or magnetic (n=30) navigation according to room availability. Venography of the coronary venous system was performed to select a target vessel for lead implantation. Guidewire access to the target vessel was achieved in 100% using magnetic navigation compared to 87% with the conventional approach (P < 0.05). Implantation success rates, total procedure and fluoroscopy times did not differ significantly between groups. No periprocedural death and no intraoperative device dysfunction occurred in either group.The magnetic guidewire ruptured in one patient. Left ventricular lead placement using magnetic guidewire navigation to engage the desired coronary sinus side branch can be successfully performed for CRT.
Carrascosa, Patricia; Cipriano, Silvina; De Zan, Macarena; Deviggiano, Alejandro; Capunay, Carlos; Cury, Ricardo C.
2015-01-01
Background Myocardial computed tomography perfusion (CTP) using conventional single energy (SE) imaging is influenced by the presence of beam hardening artifacts (BHA), occasionally resembling perfusion defects and commonly observed at the left ventricular posterobasal wall (PB). We therefore sought to explore the ability of dual energy (DE) CTP to attenuate the presence of BHA. Methods Consecutive patients without history of coronary artery disease who were referred for computed tomography coronary angiography (CTCA) due to atypical chest pain and a normal stress-rest SPECT and had absence or mild coronary atherosclerosis constituted the study population. The study group was acquired using DE and the control group using SE imaging. Results Demographical characteristics were similar between groups, as well as the heart rate and the effective radiation dose. Myocardial signal density (SD) levels were evaluated in 280 basal segments among the DE group (140 PB segments for each energy level from 40 to 100 keV; and 140 reference segments), and in 40 basal segments (at the same locations) among the SE group. Among the DE group, myocardial SD levels and myocardial SD ratio evaluated at the reference segment were higher at low energy levels, with significantly lower SD levels at increasing energy levels. Myocardial signal-to-noise ratio was not significantly influenced by the energy level applied, although 70 keV was identified as the energy level with the best overall signal-to-noise ratio. Significant differences were identified between the PB segment and the reference segment among the lower energy levels, whereas at ≥70 keV myocardial SD levels were similar. Compared to DE reconstructions at the best energy level (70 keV), SE acquisitions showed no significant differences overall regarding myocardial SD levels among the reference segments. Conclusions BHA that influence the assessment of myocardial perfusion can be attenuated using DE at 70 keV or higher. PMID:25774354
Sourwine, Mariaileen; Jeudy, Jean; Miller, Brian; Vunnam, Rama; Imanli, Hasan; Mesubi, Olurotimi; Etienne-Mesubi, Martine; See, Vincent; Shorofsky, Stephen; Dickfeld, Timm
2017-10-01
A significant number of ventricular tachycardia circuits are located close to the epicardial surface and are amendable to epicardial ablation. Epicardial fat often interferes with substrate mapping and ablation, though little is known regarding the distribution of fat and its fluctuation with the cardiac cycle. We studied 40 patients who underwent a 64-slice multidetector computed tomography in order to describe patterns of epicardial fat distribution, variation during cardiac cycle, and clinical predictors of epicardial fat. Multiplanar reconstructions were analyzed during systole and diastole in six cross-sections. Epicardial fat thickness was measured across multiple wall segments in each view. Epicardial fat was found to be thicker in areas overlying coronary vasculature (7.8 ± 2.6 mm vs 3.5 ± 0.9 mm, P = 0.001), along with the right ventricular wall (3.9 ± 0.8 mm vs 2.6 ± 0.6 mm, P = 0.001) and the ventricular base (6.1 ± 1.7 mm vs 4.6 ± 1.6 mm, P < 0.01). Epicardial fat thickness increased 27% during systole as compared to diastole (4.9 ± 2.7 mm vs 6.2 ± 3.0 mm, P = 0.04). Variation with cardiac cycle was most evident along the right ventricular wall (3.9 ± 0.8 mm vs 5.0 ± 1.3 mm, P = 0.001) and nonvascular areas (P = 0.001), especially at the ventricular base (3.7 ± 1.1 mm vs 5.3 ± 1.5 mm, P = 0.001). In multivariate logistic regression, we found that age >50 years (P = 0.031) and coronary artery disease (P = 0.023) were statistically correlated with epicardial fat >5-mm thickness and body mass index > 33 (P = 0.052) nearly so. Baseline epicardial fat thickness >5 mm is common in areas typically targeted during epicardial ablation and further increases during the cardiac cycle. Simple clinical characteristics can identify patients with >5 mm epicardial fat in which preprocedural computed tomography imaging and three-dimensional fat map reconstruction may facilitate epicardial ablation. © 2017 Wiley Periodicals, Inc.
Evolving targeted therapies for right ventricular failure.
Di Salvo, Thomas G
2015-01-01
Although right and left ventricular embryological origins, morphology and cardiodynamics differ, the notion of selectively targeted right ventricular therapies remains controversial. This review focuses on both the currently evolving pharmacologic agents targeting right ventricular failure (metabolic modulators, phosphodiesterase type V inhibitors) and future therapeutic approaches including epigenetic modulation by miRNAs, chromatin binding complexes, long non-coding RNAs, genomic editing, adoptive gene transfer and gene therapy, cell regeneration via cell transplantation and cell reprogramming and cardiac tissue engineering. Strategies for adult right ventricular regeneration will require a more holistic approach than strategies for adult left ventricular failure. Instances of right ventricular failure requiring global reconstitution of right ventricular myocardium, attractive approaches include: i) myocardial patches seeded with cardiac fibroblasts reprogrammed into cardiomyocytes in vivo by small molecules, miRNAs or other epigenetic modifiers; and ii) administration of miRNAs, lncRNAs or small molecules by non-viral vector delivery systems targeted to fibroblasts (e.g., episomes) to stimulate in vivo reprogramming of fibroblasts into cardiomyocytes. For selected heritable genetic myocardial diseases, genomic editing affords exciting opportunities for allele-specific silencing by site-specific directed silencing, mutagenesis or gene excision. Genomic editing by adoptive gene transfer affords similarly exciting opportunities for restoration of myocardial gene expression.
Tan, Qiang; Chen, Qianwei; Feng, Zhou; Shi, Xia; Tang, Jun; Tao, Yihao; Jiang, Bing; Tan, Liang; Feng, Hua; Zhu, Gang; Yang, Yunfeng; Chen, Zhi
2017-01-01
Fibrosis in ventricular system has a role in hydrocephalus following intraventricular hemorrhage (IVH). The cannabinoid receptor 2 (CB2) has been reported to participate in alleviating the fibrosis process of many diseases. However, its role in fibrosis after IVH was unclear so far, and we hypothesized that CB2 activation has potential to attenuate hydrocephalus after IVH via restricting fibrosis. So the present study was designed to investigate this hypothesis in a modified rat IVH model. Autologous non-anticoagulative blood injection model was induced to mimic ventricular extension of hemorrhage in adult Sprague-Dawley rats. Rats were randomized to receive JWH-133(CB2 agonist), SR144528 (CB2 antagonist) or saline. The lateral ventricular volumes, fibrosis in the subarachnoid space and ventricular wall, transforming growth factor-β 1(TGF-β1) in cerebrospinal fluid and brain tissue, and animal neurological scores were measured to evaluate the effects of CB2 in hydrocephalus following IVH. CB2 agonist JWH-133 significantly decreased the lateral ventricular volumes, improved the associated neurological deficits, down-regulated TGF-β1 expression, and alleviated fibrosis in the subarachnoid space and ventricular wall after IVH. All of these effects were reversed by SR144528. In conclusion, CB2 may have anti-fibrogenic effects after IVH. CB2 agonist suppressed fibrosis of ventricular system and alleviated hydrocephalus following IVH, which is partly mediated by inhibiting TGF-β1. Copyright © 2016 Elsevier B.V. All rights reserved.
Latha, Manohar; Kavitha, Ganesan
2018-02-03
Schizophrenia (SZ) is a psychiatric disorder that especially affects individuals during their adolescence. There is a need to study the subanatomical regions of SZ brain on magnetic resonance images (MRI) based on morphometry. In this work, an attempt was made to analyze alterations in structure and texture patterns in images of the SZ brain using the level-set method and Laws texture features. T1-weighted MRI of the brain from Center of Biomedical Research Excellence (COBRE) database were considered for analysis. Segmentation was carried out using the level-set method. Geometrical and Laws texture features were extracted from the segmented brain stem, corpus callosum, cerebellum, and ventricle regions to analyze pattern changes in SZ. The level-set method segmented multiple brain regions, with higher similarity and correlation values compared with an optimized method. The geometric features obtained from regions of the corpus callosum and ventricle showed significant variation (p < 0.00001) between normal and SZ brain. Laws texture feature identified a heterogeneous appearance in the brain stem, corpus callosum and ventricular regions, and features from the brain stem were correlated with Positive and Negative Syndrome Scale (PANSS) score (p < 0.005). A framework of geometric and Laws texture features obtained from brain subregions can be used as a supplement for diagnosis of psychiatric disorders.
Novel Micropatterned Cardiac Cell Cultures with Realistic Ventricular Microstructure
Badie, Nima; Bursac, Nenad
2009-01-01
Systematic studies of cardiac structure-function relationships to date have been hindered by the intrinsic complexity and variability of in vivo and ex vivo model systems. Thus, we set out to develop a reproducible cell culture system that can accurately replicate the realistic microstructure of native cardiac tissues. Using cell micropatterning techniques, we aligned cultured cardiomyocytes at micro- and macroscopic spatial scales to follow local directions of cardiac fibers in murine ventricular cross sections, as measured by high-resolution diffusion tensor magnetic resonance imaging. To elucidate the roles of ventricular tissue microstructure in macroscopic impulse conduction, we optically mapped membrane potentials in micropatterned cardiac cultures with realistic tissue boundaries and natural cell orientation, cardiac cultures with realistic tissue boundaries but random cell orientation, and standard isotropic monolayers. At 2 Hz pacing, both microscopic changes in cell orientation and ventricular tissue boundaries independently and synergistically increased the spatial dispersion of conduction velocity, but not the action potential duration. The realistic variations in intramural microstructure created unique spatial signatures in micro- and macroscopic impulse propagation within ventricular cross-section cultures. This novel in vitro model system is expected to help bridge the existing gap between experimental structure-function studies in standard cardiac monolayers and intact heart tissues. PMID:19413993
Chien, David T; Bravo, Paco; Higuchi, Takahiro; Merrill, Jennifer; Bengel, Frank M
2011-08-01
Myocardial washout of the potassium analogue (82)Rb may indicate tissue impairment. Few studies have evaluated its usefulness for viability assessment, and controversial results were reported. We revisited this topic using list-mode positron emission tomography (PET)/CT. A total of 22 patients with chronic ischemic cardiomyopathy (ICM) and 11 control subjects with normal CT coronary angiogram were studied. Rest (82)Rb PET/CT studies were acquired in list mode and resampled to static, gated, and dynamic images. Using a 17-segment model, (82)Rb washout was determined by monoexponential fitting of myocardial time-activity curves. In ICM patients, (18)F-fluorodeoxyglucose (FDG) studies were obtained in the same session and segments were classified as normally perfused, mismatch, or matched defect. (82)Rb washout was minimal and homogeneous in control subjects. Normally perfused segments of ICM did not differ (p = 0.33). ICM patients had a left ventricular ejection fraction (LVEF) of 25 ± 12%, 25/353 mismatched, and 46/353 matched defect segments. (82)Rb washout was higher in hypoperfused vs normal segments (p < 0.05), but not different between mismatch and matched defect (p = 0.18). Intraindividual analysis in nine patients showing both FDG mismatch and matched defect confirmed absence of differences. Overall, segmental (82)Rb washout correlated inversely with (82)Rb uptake (r = -0.70; p < 0.05) and less well with FDG uptake (r = -0.31; p < 0.05). Using state-of-the-art PET/CT technology for myocardial viability assessment, (82)Rb washout does not distinguish between perfusion/metabolism patterns of hibernating myocardium and scar. Tissue integrity may be at least partially impaired in hibernation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borovetz, H.S.; Shaffer, F.; Schaub, R.
This paper discusses a series of experiments to visualize and measure flow fields in the Novacor left ventricular assist system (LVAS). The experiments utilize a multiple exposure, optical imaging technique called fluorescent image tracking velocimetry (FITV) to hack the motion of small, neutrally-buoyant particles in a flowing fluid.
Controversies in cardiovascular care: silent myocardial ischemia
NASA Technical Reports Server (NTRS)
Hollenberg, N. K.
1987-01-01
The objective evidence of silent myocardial ischemia--ischemia in the absence of classical chest pain--includes ST-segment shifts (usually depression), momentary left ventricular failure, and perfusion defects on scintigraphic studies. Assessment of angina patients with 24-hour ambulatory monitoring may uncover episodes of silent ischemia, the existence of which may give important information regarding prognosis and may help structure a more effective therapeutic regimen. The emerging recognition of silent ischemia as a significant clinical entity may eventually result in an expansion of current therapy--not only to ameliorate chest pain, but to minimize or eliminate ischemia in the absence of chest pain.
Kumar, Avs Anil; Kumar, P G; Swami, Ajay; Dinker, Yateendra
2018-01-01
After a primary transluminal coronary angioplasty (PTCA) following AMI (acute myocardial infarction), the perfusion defect and LV (left ventricular) function recover/change over a period of time. The analysis immediately after the procedure may not be true depiction of the exact success of the procedure. There is varying and scanty information available on the natural course of changes in these parameters after a successful PTCA. We hypothesized that majority of change occurs at 3-4 month period. Hence, we undertook this study on the natural course of recovery/changes occurring in perfusion defect size and LV function in first 3 months after primary angioplasty MATERIAL AND METHODS: 30 consecutive cases of first AMI who were taken up for Primary angioplasty were enrolled into the study. Resting MPI(Myocardial perfusion imaging) was done within 24-72 hrs of admission using Tc-99m-Tetrofosmin and after 10-14 weeks. Analysis of LVEF (left ventricular ejection fraction), summed segmental score and extent of perfusion defect was done. Images were processed using autocardiac software of emory tool box and quantification was done using QPS (quantitative perfusion SPECT) and QGS (qualitative perfusion SPECT) softwares. 20 segment scoring method was used for quantification on bull's eye images. Student t test (two tailed, dependent) was used to find the significance of study parameters on continuous scale within each group. Effect size was computed to find the effect. Pearson correlation between perfusion defect and LVEF was performed at acute stage and after 10-14 weeks. The average acute perfusion defect extent was 19.76 ± 12.89% which after 3months became 16.79 ± 12.61%. The summed segmental score changed from 14.31 ± 10.58 to 11.38 ± 10.03 and LVEF improved from 48.40 ± 13.15% to 53.37 ± 12.8%. There was significant improvement in LVEF from acute setting to 10-14 weeks (p = 0.001). There was significant lowering of summed score (p = 0.007). Perfusion defect size showed significant reduction (p = 0.030). Three patients showed deterioration in perfusion defect size and in summed score with reduction in LVEF. Four patients had no change in any of the parameters. Correlation between perfusion defect and LVEF was strong both at baseline (r = -0.705, p < 0.001) and after 10-18 weeks (r = -0.766, p < 0.001). The changes we found in 3 months are similar to earlier studies and also to studies using follow up at 6 months to 1 year. We feel that 3 months is a good enough time to accurately assess the success of primary angioplasty.
An architecture for rapid prototyping of control schemes for artificial ventricles.
Ficola, Antonio; Pagnottelli, Stefano; Valigi, Paolo; Zoppitelli, Maurizio
2004-01-01
This paper presents an experimental system aimed at rapid prototyping of feedback control schemes for ventricular assist devices, and artificial ventricles in general. The system comprises a classical mock circulatory system, an actuated bellow-based ventricle chamber, and a software architecture for control schemes implementation and experimental data acquisition, visualization and storing. Several experiments have been carried out, showing good performance of ventricular pressure tracking control schemes.
A servo-controlled canine model of stable severe ischemic left ventricular failure.
Wagner, Richard L; Hood, William B; Howland, Peter A
2009-12-01
Reversible left ventricular failure was produced in conscious dogs by compromise of the coronary circulation. In animals with prior left anterior descending coronary artery occlusion, mean left atrial pressure (LAP) was incorporated into an automatic feedback control system used to inflate a balloon cuff on the circumflex (Cfx) coronary artery. The system could produce stable increases in LAP to 15-20 mm Hg. The dominating system transfer function was the ratio of LAP to balloon volume (BV), which was characterized by a fixed delay (5 s), with LAP/BV = (8e(-jomegatau ))/(0.02 + jomega). The system was stabilized by a phase lead network to reduce oscillations of LAP. A total of seven experiments were conducted in three dogs, and testing of inotropic agents was possible in three experiments under stable conditions with the pump off after an hour or more of operation. Problems encountered were 0.003-0.008 Hz oscillations in LAP in three experiments, which could usually be controlled by reducing the system gain. Late stage ventricular fibrillation occurred in all three animals, but defibrillation was easily accomplished after deflating the Cfx balloon. This system produces reversible left ventricular failure solely due to ischemia, thus closely simulating clinical heart failure due to coronary insufficiency.
Wink, Jeroen; de Wilde, Rob B P; Wouters, Patrick F; van Dorp, Eveline L A; Veering, Bernadette Th; Versteegh, Michel I M; Aarts, Leon P H J; Steendijk, Paul
2016-10-18
Blockade of cardiac sympathetic fibers by thoracic epidural anesthesia may affect right ventricular function and interfere with the coupling between right ventricular function and right ventricular afterload. Our main objectives were to study the effects of thoracic epidural anesthesia on right ventricular function and ventricular-pulmonary coupling. In 10 patients scheduled for lung resection, right ventricular function and its response to increased afterload, induced by temporary, unilateral clamping of the pulmonary artery, was tested before and after induction of thoracic epidural anesthesia using combined pressure-conductance catheters. Thoracic epidural anesthesia resulted in a significant decrease in right ventricular contractility (ΔESV 25 : +25.5 mL, P=0.0003; ΔEes: -0.025 mm Hg/mL, P=0.04). Stroke work, dP/dt MAX , and ejection fraction showed a similar decrease in systolic function (all P<0.05). A concomitant decrease in effective arterial elastance (ΔEa: -0.094 mm Hg/mL, P=0.004) yielded unchanged ventricular-pulmonary coupling. Cardiac output, systemic vascular resistance, and mean arterial blood pressure were unchanged. Clamping of the pulmonary artery significantly increased afterload (ΔEa: +0.226 mm Hg/mL, P<0.001). In response, right ventricular contractility increased (ΔESV 25 : -26.6 mL, P=0.0002; ΔEes: +0.034 mm Hg/mL, P=0.008), but ventricular-pulmonary coupling decreased (Δ(Ees/Ea) = -0.153, P<0.0001). None of the measured indices showed significant interactive effects, indicating that the effects of increased afterload were the same before and after thoracic epidural anesthesia. Thoracic epidural anesthesia impairs right ventricular contractility but does not inhibit the native positive inotropic response of the right ventricle to increased afterload. Right ventricular-pulmonary arterial coupling was decreased with increased afterload but not affected by the induction of thoracic epidural anesthesia. URL: http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2844. Unique identifier: NTR2844. © 2016 American Heart Association, Inc.
Monitoring ventricular function at rest and during exercise with a nonimaging nuclear detector.
Wagner, H N; Rigo, P; Baxter, R H; Alderson, P O; Douglass, K H; Housholder, D F
1979-05-01
A portable nonimaging device, the nuclear stethoscope, for measuring beat to beat ventricular time-activity curves in normal people and patients with heart disease, both at rest and during exercise, is being developed and evaluated. The latest device has several operating modes that facilitate left ventricular and background localization, measurement of transit times and automatic calculation and display of left ventricular ejection fraction. The correlation coefficient of left ventricular ejection fraction obtained with the device and with a camera-computer system was 0.92 in 35 subjects. During bicycle exercise the ejection fraction in 15 normal persons increased from 44 to 64 percent (P less than 0.001), whereas among 12 patients with heart disease it was unchanged in 5 and decreased in 7.
[Extracorporeal ventriculoatrial shunt with the use of one-way ball valve].
Kubo, Shigeki; Takimoto, Hiroshi; Hosoi, Kazuki; Toyota, Shingo; Takakura, Shuji; Hayashi, Yasuhiro; Ueno, Masato; Morisako, Toshitaka; Karasawa, Jun; Ninaga, Hideo; Yoshimine, Toshiki
2002-04-01
We developed a simple system of an "extracorporeal" ventriculoatrial (VA) shunt using a one-way ball valve (Acty valve II, Kaneka Medix) to release the patient from postoperative constraint during the ventricular drainage. The system is constructed in such a way that the ventricular drainage tube is connected to the central venous catheter via a one-way valve. The CSF is regulated by using the valve and is diverted into the systemic circulation as in the conventional ventriculoatrial shunt. After 2 or 3 weeks of CSF diversion through the extracorporeal VA shunt, a ventriculoperitoneal shunt is placed if hydrocephalus is apparent by temporary occlusion of the system. We applied this system to 4 patients with hydrocephalus, and we found it useful and free from adverse effects. The patient was freed from physical constraint involved in conventional ventricular drainage and an effective program of early rehabilitation was able to be started.
Higher sympathetic nerve activity during ventricular (VVI) than during dual-chamber (DDD) pacing
NASA Technical Reports Server (NTRS)
Taylor, J. A.; Morillo, C. A.; Eckberg, D. L.; Ellenbogen, K. A.
1996-01-01
OBJECTIVES: We determined the short-term effects of single-chamber ventricular pacing and dual-chamber atrioventricular (AV) pacing on directly measured sympathetic nerve activity. BACKGROUND: Dual-chamber AV cardiac pacing results in greater cardiac output and lower systemic vascular resistance than does single-chamber ventricular pacing. However, it is unclear whether these hemodynamic advantages result in less sympathetic nervous system outflow. METHODS: In 13 patients with a dual-chamber pacemaker, we recorded the electrocardiogram, noninvasive arterial pressure (Finapres), respiration and muscle sympathetic nerve activity (microneurography) during 3 min of underlying basal heart rate and 3 min of ventricular and AV pacing at rates of 60 and 100 beats/min. RESULTS: Arterial pressure was lowest and muscle sympathetic nerve activity was highest at the underlying basal heart rate. Arterial pressure increased with cardiac pacing and was greater with AV than with ventricular pacing (change in mean blood pressure +/- SE: 10 +/- 3 vs. 2 +/- 2 mm Hg at 60 beats/min; 21 +/- 5 vs. 14 +/- 2 mm Hg at 100 beats/min; p < 0.05). Sympathetic nerve activity decreased with cardiac pacing and the decline was greater with AV than with ventricular pacing (60 beats/min -40 +/- 11% vs. -17 +/- 7%; 100 beats/min -60 +/- 9% vs. -48 +/- 10%; p < 0.05). Although most patients showed a strong inverse relation between arterial pressure and muscle sympathetic nerve activity, three patients with severe left ventricular dysfunction (ejection fraction < or = 30%) showed no relation between arterial pressure and sympathetic activity. CONCLUSIONS: Short-term AV pacing results in lower sympathetic nerve activity and higher arterial pressure than does ventricular pacing, indicating that cardiac pacing mode may influence sympathetic outflow simply through arterial baroreflex mechanisms. We speculate that the greater incidence of adverse outcomes in patients treated with single-chamber ventricular rather than dual-chamber pacing may be due in part to increased sympathetic nervous outflow.
Zablocki, Jeff A; Elzein, Elfatih; Li, Xiaofen; Koltun, Dmitry O; Parkhill, Eric Q; Kobayashi, Tetsuya; Martinez, Ruben; Corkey, Britton; Jiang, Haibo; Perry, Thao; Kalla, Rao; Notte, Gregory T; Saunders, Oliver; Graupe, Michael; Lu, Yafan; Venkataramani, Chandru; Guerrero, Juan; Perry, Jason; Osier, Mark; Strickley, Robert; Liu, Gongxin; Wang, Wei-Qun; Hu, Lufei; Li, Xiao-Jun; El-Bizri, Nesrine; Hirakawa, Ryoko; Kahlig, Kris; Xie, Cheng; Li, Cindy Hong; Dhalla, Arvinder K; Rajamani, Sridharan; Mollova, Nevena; Soohoo, Daniel; Lepist, Eve-Irene; Murray, Bernard; Rhodes, Gerry; Belardinelli, Luiz; Desai, Manoj C
2016-10-03
Late sodium current (late I Na ) is enhanced during ischemia by reactive oxygen species (ROS) modifying the Na v 1.5 channel, resulting in incomplete inactivation. Compound 4 (GS-6615, eleclazine) a novel, potent, and selective inhibitor of late I Na , is currently in clinical development for treatment of long QT-3 syndrome (LQT-3), hypertrophic cardiomyopathy (HCM), and ventricular tachycardia-ventricular fibrillation (VT-VF). We will describe structure-activity relationship (SAR) leading to the discovery of 4 that is vastly improved from the first generation late I Na inhibitor 1 (ranolazine). Compound 4 was 42 times more potent than 1 in reducing ischemic burden in vivo (S-T segment elevation, 15 min left anteriorior descending, LAD, occlusion in rabbits) with EC 50 values of 190 and 8000 nM, respectively. Compound 4 represents a new class of potent late I Na inhibitors that will be useful in delineating the role of inhibitors of this current in the treatment of patients.
Detection and Prevention of Cardiac Arrhythmias During Space Flight
NASA Technical Reports Server (NTRS)
Pillai, Dilip; Rosenbaum, David S.; Liszka, Kathy J.; York, David W.; Mackin, Michael A.; Lichter, Michael J.
2004-01-01
There have been reports suggesting that long-duration space flight might lead to an increased risk of potentially serious heart rhythm disturbances. If space flight does, in fact, significantly decrease cardiac electrical stability, the effects could be catastrophic, potentially leading to sudden cardiac death. It will be important to determine the mechanisms underlying this phenomenon in order to prepare for long-term manned lunar and interplanetary missions and to develop appropriate countermeasures. Electrical alternans affecting the ST segment and T-wave have been demonstrated to be common among patients at increased risk for ventricular arrhythmias. Subtle electrical alternans on the ECG may serve as a noninvasive marker of vulnerability to ventricular arrhythmias. We are studying indices of electrical instability in the heart for long term space missions by non-invasively measuring microvolt level T-wave alternans in a reduced gravity environment. In this investigation we are using volunteer subjects on the KC-135 aircraft as an initial study of the effect of electrical adaptation of the heart to microgravity. T-wave alternans will be analyzed for heart rate variability and QT restitution curve plotting will be compared for statistical significance.
[Complex ventricular arrhythmias and carvedilol: efficacy in hemodialyzed uremic patients].
Cice, G; Tagliamonte, E; Ferrara, L; Di Benedetto, A; Iacono, A
1998-06-01
Carvedilol has been shown to be effective in systemic hypertension and coronary artery disease in patients with end-stage renal disease, on maintenance hemodialysis. The aim of our study was to assess the effects of carvedilol on ventricular arrhythmias in these patients. Ninety-eight uremic patients maintained on hemodialysis, with complex ventricular arrhythmias (class III, IV and V of Lown's classification), not only during dialysis, were included in the study. They were divided into two groups, with mild-to-moderate hypertension or coronary artery disease. The efficacy and safety of carvedilol (50 mg/day) was compared to placebo in a 6-week randomized, double-blind study. Carvedilol significantly reduced, in both hypertensive and ischemic patients, total ventricular premature contractions (82.7 +/- 11.3 vs 358.1 +/- 73.9, p < 0.001; 88.3 +/- 24.4 vs 369.9 +/- 77.8, p < 0.001), repetitive ventricular premature contractions (1.3 +/- 1.3 vs 6.3 +/- 3.5, p < 0.001; 1.2 +/- 0.7 vs 6.9 +/- 2.6, p < 0.001) and episodes of ventricular tachycardia (1.1 +/- 1.2 vs 11.8 +/- 7.5, p < 0.001; 1.4 +/- 1.2 vs 14.0 +/- 8.3, p < 0.001). In placebo-treated patients, instead, these parameters were not significantly changed (329.1 +/- 76.5 vs 361.7 +/- 71.7, NS, and 324.6 +/- 79.7 vs 359.3 +/- 58.1, NS; 6.2 +/- 3.7 vs 7.3 +/- 3.7, NS, and 4.9 +/- 2.2 vs 6.1 +/- 3.2, NS; 9.8 +/- 6.3 vs 13.3 +/- 8.0, NS, and 9.0 +/- 6.2 vs 12.4 +/- 7.8, NS). Carvedilol confirmed a significant effect on myocardial ischemia and systemic hypertension. No significant side effects were reported. Ventricular arrhythmias are frequent in patients with end-stage renal disease maintained on hemodialysis. They are often due to an underlying cardiac disease, namely systemic hypertension with left ventricular hypertrophy and coronary artery disease. The results of our study show that the antiarrhythmic effect of carvedilol is linked, at least partly, to an improvement of the underlying cardiac disease. Uremic patients have a chronic increase in adrenergic tone, with a direct correlation between norepinephrine plasmatic concentration and frequence of premature ventricular contractions. Beta-blockers are very important in these patients because of their modulation on the adrenergic system. They also reduce potassium flow, from extracellular to intracellular fluid. Therefore carvedilol can affect the sudden hypokalemia occurring in the first phase of hemodialysis treatment, that may be an important cause of intradialytic arrhythmias.
[Wearable Automatic External Defibrillators].
Luo, Huajie; Luo, Zhangyuan; Jin, Xun; Zhang, Leilei; Wang, Changjin; Zhang, Wenzan; Tu, Quan
2015-11-01
Defibrillation is the most effective method of treating ventricular fibrillation(VF), this paper introduces wearable automatic external defibrillators based on embedded system which includes EGG measurements, bioelectrical impedance measurement, discharge defibrillation module, which can automatic identify VF signal, biphasic exponential waveform defibrillation discharge. After verified by animal tests, the device can realize EGG acquisition and automatic identification. After identifying the ventricular fibrillation signal, it can automatic defibrillate to abort ventricular fibrillation and to realize the cardiac electrical cardioversion.
A porcine model for acute ischaemic right ventricular dysfunction.
Haraldsen, Pernille; Lindstedt, Sandra; Metzsch, Carsten; Algotsson, Lars; Ingemansson, Richard
2014-01-01
To establish an experimental model for acute ischaemic isolated right ventricular dysfunction and the subsequent haemodynamic changes. An open-chest porcine model with ischaemic dysfunction of the right ventricle induced by ligation of the three main branches supporting the right ventricular free wall. Invasive monitoring of mean arterial blood pressure (MAP), central venous pressure (CVP), left atrial pressure (LAP) and right ventricular pressure (RVP); ultrasonic measurement of cardiac output (CO) and calculation of haemodynamic parameters such as stroke volume (SV), systemic vascular resistance (SVR), pulmonary vascular resistance (PVR) and right ventricular stroke work (RVSW) using standard formulae. The ischaemic challenge to the right ventricle resulted in a significant (≥30%) reduction in RVSW associated with an increase (6-25%) in CVP and reduction (8-18%) in pulmonary artery pressure (PAP) despite unchanged PVR, all reflecting the failing right ventricle. There was also a significant drop in CO (14-22%) despite unchanged LAP indicating lessened transpulmonary delivery of left ventricular preload due to the failing right ventricle causing the haemodynamic compromise rather than left ventricular failure. Supraventricular and ventricular arrhythmias occurred in three and two out of seven pigs, respectively-all of which except one were successfully resuscitated with cardioversion and/or defibrillation. This novel open-chest porcine model of induced ischaemia of the right ventricular free wall resulted in significant haemodynamic compromise confirmed using standard haemodynamic measurements making it useful for further research on acute, ischaemic isolated right ventricular failure.
Manson, Amy; Poyade, Matthieu; Rea, Paul
2015-10-19
The use of computer-aided learning in education can be advantageous, especially when interactive three-dimensional (3D) models are used to aid learning of complex 3D structures. The anatomy of the ventricular system of the brain is difficult to fully understand as it is seldom seen in 3D, as is the flow of cerebrospinal fluid (CSF). This article outlines a workflow for the creation of an interactive training tool for the cerebral ventricular system, an educationally challenging area of anatomy. This outline is based on the use of widely available computer software packages. Using MR images of the cerebral ventricular system and several widely available commercial and free software packages, the techniques of 3D modelling, texturing, sculpting, image editing and animations were combined to create a workflow in the creation of an interactive educational and training tool. This was focussed on cerebral ventricular system anatomy, and the flow of cerebrospinal fluid. We have successfully created a robust methodology by using key software packages in the creation of an interactive education and training tool. This has resulted in an application being developed which details the anatomy of the ventricular system, and flow of cerebrospinal fluid using an anatomically accurate 3D model. In addition to this, our established workflow pattern presented here also shows how tutorials, animations and self-assessment tools can also be embedded into the training application. Through our creation of an established workflow in the generation of educational and training material for demonstrating cerebral ventricular anatomy and flow of cerebrospinal fluid, it has enormous potential to be adopted into student training in this field. With the digital age advancing rapidly, this has the potential to be used as an innovative tool alongside other methodologies for the training of future healthcare practitioners and scientists. This workflow could be used in the creation of other tools, which could be developed for use not only on desktop and laptop computers but also smartphones, tablets and fully immersive stereoscopic environments. It also could form the basis on which to build surgical simulations enhanced with haptic interaction.
NASA Astrophysics Data System (ADS)
Larsson, David; Spühler, Jeannette H.; Günyeli, Elif; Weinkauf, Tino; Hoffman, Johan; Colarieti-Tosti, Massimiliano; Winter, Reidar; Larsson, Matilda
2017-03-01
Echocardiography is the most commonly used image modality in cardiology, assessing several aspects of cardiac viability. The importance of cardiac hemodynamics and 4D blood flow motion has recently been highlighted, however such assessment is still difficult using routine echo-imaging. Instead, combining imaging with computational fluid dynamics (CFD)-simulations has proven valuable, but only a few models have been applied clinically. In the following, patient-specific CFD-simulations from transthoracic dobutamin stress echocardiography have been used to analyze the left ventricular 4D blood flow in three subjects: two with normal and one with reduced left ventricular function. At each stress level, 4D-images were acquired using a GE Vivid E9 (4VD, 1.7MHz/3.3MHz) and velocity fields simulated using a presented pathway involving endocardial segmentation, valve position identification, and solution of the incompressible Navier-Stokes equation. Flow components defined as direct flow, delayed ejection flow, retained inflow, and residual volume were calculated by particle tracing using 4th-order Runge-Kutta integration. Additionally, systolic and diastolic average velocity fields were generated. Results indicated no major changes in average velocity fields for any of the subjects. For the two subjects with normal left ventricular function, increased direct flow, decreased delayed ejection flow, constant retained inflow, and a considerable drop in residual volume was seen at increasing stress. Contrary, for the subject with reduced left ventricular function, the delayed ejection flow increased whilst the retained inflow decreased at increasing stress levels. This feasibility study represents one of the first clinical applications of an echo-based patient-specific CFD-model at elevated stress levels, and highlights the potential of using echo-based models to capture highly transient flow events, as well as the ability of using simulation tools to study clinically complex phenomena. With larger patient studies planned for the future, and with the possibility of adding more anatomical features into the model framework, the current work demonstrates the potential of patient-specific CFD-models as a tool for quantifying 4D blood flow in the heart.
Goo, Hyun Woo; Park, Sang-Hyub
2015-12-01
To assess agreement between two semi-automatic, three-dimensional (3D) computed tomography (CT) ventricular volumetry methods with different user interactions in patients with congenital heart disease. In 30 patients with congenital heart disease (median age 8 years, range 5 days-33 years; 20 men), dual-source, multi-section, electrocardiography-synchronized cardiac CT was obtained at the end-systolic (n = 22) and/or end-diastolic (n = 28) phase. Nineteen left ventricle end-systolic (LV ESV), 28 left ventricle end-diastolic (LV EDV), 22 right ventricle end-systolic (RV ESV), and 28 right ventricle end-diastolic volumes (RV EDV) were successfully calculated using two semi-automatic, 3D segmentation methods with different user interactions (high in method 1, low in method 2). The calculated ventricular volumes of the two methods were compared and correlated. A P value <0.05 was considered statistically significant. LV ESV (35.95 ± 23.49 ml), LV EDV (88.76 ± 61.83 ml), and RV ESV (46.87 ± 47.39 ml) measured by method 2 were slightly but significantly smaller than those measured by method 1 (41.25 ± 26.94 ml, 92.20 ± 62.69 ml, 53.61 ± 50.08 ml for LV ESV, LV EDV, and RV ESV, respectively; P ≤ 0.02). In contrast, no statistically significant difference in RV EDV (122.57 ± 88.57 ml in method 1, 123.83 ± 89.89 ml in method 2; P = 0.36) was found between the two methods. All ventricular volumes showed very high correlation (R = 0.978, 0.993, 0.985, 0.997 for LV ESV, LV EDV, RV ESV, and RV EDV, respectively; P < 0.001) between the two methods. In patients with congenital heart disease, 3D CT ventricular volumetry shows good agreement and high correlation between the two methods, but method 2 tends to slightly underestimate LV ESV, LV EDV, and RV ESV.
Ventriculogram segmentation using boosted decision trees
NASA Astrophysics Data System (ADS)
McDonald, John A.; Sheehan, Florence H.
2004-05-01
Left ventricular status, reflected in ejection fraction or end systolic volume, is a powerful prognostic indicator in heart disease. Quantitative analysis of these and other parameters from ventriculograms (cine xrays of the left ventricle) is infrequently performed due to the labor required for manual segmentation. None of the many methods developed for automated segmentation has achieved clinical acceptance. We present a method for semi-automatic segmentation of ventriculograms based on a very accurate two-stage boosted decision-tree pixel classifier. The classifier determines which pixels are inside the ventricle at key ED (end-diastole) and ES (end-systole) frames. The test misclassification rate is about 1%. The classifier is semi-automatic, requiring a user to select 3 points in each frame: the endpoints of the aortic valve and the apex. The first classifier stage is 2 boosted decision-trees, trained using features such as gray-level statistics (e.g. median brightness) and image geometry (e.g. coordinates relative to user supplied 3 points). Second stage classifiers are trained using the same features as the first, plus the output of the first stage. Border pixels are determined from the segmented images using dilation and erosion. A curve is then fit to the border pixels, minimizing a penalty function that trades off fidelity to the border pixels with smoothness. ED and ES volumes, and ejection fraction are estimated from border curves using standard area-length formulas. On independent test data, the differences between automatic and manual volumes (and ejection fractions) are similar in size to the differences between two human observers.
Zhou, Jia; Pu, Da-Rong; Tian, Lei-Qi; Tong, Hai; Liu, Hong-Yu; Tang, Yan; Zhou, Qi-Chang
2015-05-28
Our study aimed to investigate the feasibility of velocity vector imaging (VVI) to analyze left ventricular (LV) myocardial mechanics in rabbits at basal state. The animals used in this study were 30 New Zealand white rabbits. All rabbits underwent routine echocardiography under VVI-mode at basal state. The 2-dimensional (2-D) echocardiography images acquired included parasternal left long-axis views and short-axis views at the level of LV mitral valve, papillary muscles, and apex. Images were analyzed by VVI software. At basal state, longitudinal LV velocity decreased from the basal to the apical segment (P<0.05). In the short axis direction, the highest peak myocardial velocity was found between the anterior septum and anterior wall for each segment at the same level; the peak strains and strain rates (SR) were the highest in the anterior and lateral wall compared to other segments (all P<0.05). During systole, LV base rotated in a clockwise direction and LV apex rotated in a counter-clockwise direction, while during diastole, both LV base and apex rotated in the direction opposite to systole. The rotation angle, rotation velocity and unwinding velocity in the apical segment were greater than the basal segment (P<0.05). VVI is a reliable tool for evaluating LV myocardial mechanics in rabbits at basal state, and the LV long-axis short-axis and torsional motions reflect the normal regular patterns. Our study lays the foundation for future experimental approaches in rabbit models and for other applications related to the study of human myocardial mechanics.
Cuenin, Léo; Lamoureux, Sophie; Schaaf, Mathieu; Bochaton, Thomas; Monassier, Jean-Pierre; Claeys, Marc J; Rioufol, Gilles; Finet, Gérard; Garcia-Dorado, David; Angoulvant, Denis; Elbaz, Meyer; Delarche, Nicolas; Coste, Pierre; Metge, Marc; Perret, Thibault; Motreff, Pascal; Bonnefoy-Cudraz, Eric; Vanzetto, Gérald; Morel, Olivier; Boussaha, Inesse; Ovize, Michel; Mewton, Nathan
2018-04-25
Up to 25% of patients with ST elevation myocardial infarction (STEMI) have ST segment re-elevation after initial regression post-reperfusion and there are few data regarding its prognostic significance.Methods and Results:A standard 12-lead electrocardiogram (ECG) was recorded in 662 patients with anterior STEMI referred for primary percutaneous coronary intervention (PPCI). ECGs were recorded 60-90 min after PPCI and at discharge. ST segment re-elevation was defined as a ≥0.1-mV increase in STMax between the post-PPCI and discharge ECGs. Infarct size (assessed as creatine kinase [CK] peak), echocardiography at baseline and follow-up, and all-cause death and heart failure events at 1 year were assessed. In all, 128 patients (19%) had ST segment re-elevation. There was no difference between patients with and without re-elevation in infarct size (CK peak [mean±SD] 4,231±2,656 vs. 3,993±2,819 IU/L; P=0.402), left ventricular (LV) ejection fraction (50.7±11.6% vs. 52.2±10.8%; P=0.186), LV adverse remodeling (20.1±38.9% vs. 18.3±30.9%; P=0.631), or all-cause mortality and heart failure events (22 [19.8%] vs. 106 [19.2%]; P=0.887) at 1 year. Among anterior STEMI patients treated by PPCI, ST segment re-elevation was present in 19% and was not associated with increased infarct size or major adverse events at 1 year.
Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J
1995-01-01
This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.
Dangers of collapsible ventricular drainage systems. Technical note.
Kaye, A H; Wallace, D
1982-02-01
Ventricular drainage systems employing a collapsible plastic bag for fluid collection were postulated to cause an increasing back-pressure produced in part by the elasticity of the bag. This postulate was shown to be correct in an experimental situation. There was a logarithmic rise in cerebrospinal fluid pressure as the bag filled. By increasing the size of the bag, the problem was overcome.
Levy, Philip T.; Sanchez, Aura; Machefsky, Aliza; Fowler, Susan; Holland, Mark R.; Singh, Gautam K.
2014-01-01
Background Establishment of the range of normal values and associated variations of two-dimensional speckle-tracking echocardiography (2DSTE) derived right ventricular (RV) strain is a prerequisite for its routine clinical application in children. The objectives of this study were to perform a meta-analysis of normal ranges of RV longitudinal strain measurements derived by 2DSTE in children and identify confounders that may contribute to differences in reported measures. Methods A systematic review was launched in PubMed, Embase, Scopus, Cochrane, and ClinicTrials.gov. Search hedges were created to cover the concepts of pediatrics, speckle-tracking echocardiography, and right heart ventricle. Two investigators independently identified and included studies if they reported the 2DSTE derived RV strain measures: RV peak global longitudinal strain (pGLS), systolic strain rate (pGLSRs), early diastolic strain rate (pGLSRe), late diastolic strain rate (pGLSRa), or segmental longitudinal strain at the apical, mid, and basal ventricular levels in healthy children. Quality and reporting of the studies were assessed. The weighted mean was estimated by using random-effects with 95% confidence intervals (CI), heterogeneity was assessed by the Cochran's Q statistic and the inconsistency index (I2), and publication bias was evaluated using funnel plots and the Egger test. Effects of demographic, clinical, equipment, and software variables were assessed in a meta-regression. Results The search identified 226 children from 10 studies. The reported normal mean values of pGLS among the studies varied from −20.80% to −34.10% (mean, −29.03%, 95%CI, −31.52% to −26.54%), pGLSRs varied from −1.30 to −2.40 1/sec (mean, −1.88, 95%CI, −2.10 to −1.59), pGLSRe ranged from 1.7 to 2.69 1/sec (mean, 2.34, 95%CI, 2.00 to 2.67) and pGLSRa ranged from 1.00 to 1.30 1/sec (mean, 1.18, 95% CI, 1.04 to 1.33). A significant base-to-apex segmental strain gradient (p <0.05) was observed in the right ventricular free wall. There was significant between-study heterogeneity and inconsistency (I2>88% and p<0.01 for each strain measure), which was not explained by age, gender, body surface area, heart rate, frame rate, tissue tracking methodology, equipment, or software. The meta-regression showed that these effects were not significant determinants of variations among normal ranges of strain values. There was no evidence of publication bias (Egger test, p=0.59). Conclusions This study is the first to define normal values of two-dimensional speckle tracking echocardiographic (2DSTE) derived right ventricle strain in children on the basis of a meta-analysis. The normal mean value in children for RV global strain is −29.03% (95% CI, −31.52% to −26.54%). The normal mean value for RV global systolic strain rate is −1.88 1/sec (95% CI, −2.10 to −1.59). RV segmental strain has a stable base-to-apex gradient that highlights the dominance of deep longitudinal layers of the RV that are aligned base to apex. Variations among different normal ranges do not appear to be dependent on differences in demographic, clinical, or equipment parameters in this meta-analysis. All of the eligible studies used equipment and software from one manufacturer, General Electric (GE). PMID:24582163
Current Perspectives on Systemic Hypertension in Heart Failure with Preserved Ejection Fraction.
Tam, Marty C; Lee, Ran; Cascino, Thomas M; Konerman, Matthew C; Hummel, Scott L
2017-02-01
Heart failure with preserved ejection fraction (HFpEF) is a prevalent but incompletely understood syndrome. Traditional models of HFpEF pathophysiology revolve around systemic HTN and other causes of increased left ventricular afterload leading to left ventricular hypertrophy (LVH) and diastolic dysfunction. However, emerging models attribute the development of HFpEF to systemic proinflammatory changes secondary to common comorbidities which include HTN. Alterations in passive ventricular stiffness, ventricular-arterial coupling, peripheral microvascular function, systolic reserve, and chronotropic response occur. As a result, HFpEF is heterogeneous in nature, making it difficult to prescribe uniform therapies to all patients. Nonetheless, treating systemic HTN remains a cornerstone of HFpEF management. Antihypertensive therapies have been linked to LVH regression and improvement in diastolic dysfunction. However, to date, no therapies have definitive mortality benefit in HFpEF. Non-pharmacologic management for HTN, including dietary modification, exercise, and treating sleep disordered breathing, may provide some morbidity benefit in the HFpEF population. Future research is need to identify effective treatments, perhaps in more specific subgroups, and focus may need to shift from reducing mortality to improving exercise capacity and symptoms. Tailoring antihypertensive therapies to specific phenotypes of HFpEF may be an important component of this strategy.
NASA Astrophysics Data System (ADS)
Manzke, R.; Bornstedt, A.; Lutz, A.; Schenderlein, M.; Hombach, V.; Binner, L.; Rasche, V.
2010-02-01
Various multi-center trials have shown that cardiac resynchronization therapy (CRT) is an effective procedure for patients with end-stage drug invariable heart failure (HF). Despite the encouraging results of CRT, at least 30% of patients do not respond to the treatment. Detailed knowledge of the cardiac anatomy (coronary venous tree, left ventricle), functional parameters (i.e. ventricular synchronicity) is supposed to improve CRT patient selection and interventional lead placement for reduction of the number of non-responders. As a pre-interventional imaging modality, cardiac magnetic resonance (CMR) imaging has the potential to provide all relevant information. With functional information from CMR optimal implantation target sites may be better identified. Pre-operative CMR could also help to determine whether useful vein target segments are available for lead placement. Fused with X-ray, the mainstay interventional modality, improved interventional guidance for lead-placement could further help to increase procedure outcome. In this contribution, we present novel and practicable methods for a) pre-operative functional and anatomical imaging of relevant cardiac structures to CRT using CMR, b) 2D-3D registration of CMR anatomy and functional meshes with X-ray vein angiograms and c) real-time capable breathing motion compensation for improved fluoroscopy mesh overlay during the intervention based on right ventricular pacer lead tracking. With these methods, enhanced interventional guidance for left ventricular lead placement is provided.
Stankovic, Ivan; Janicijevic, Aleksandra; Dimic, Aleksandra; Stefanovic, Milica; Vidakovic, Radosav; Putnikovic, Biljana; Neskovic, Aleksandar N
2018-03-01
Bundle branch blocks (BBB)-related mechanical dyssynchrony and dispersion may improve patient selection for device therapy, but their effect on the natural history of this patient population is unknown. A total of 155 patients with LVEF ≤ 35% and BBB, not treated with device therapy, were included. Mechanical dyssynchrony was defined as the presence of either septal flash or apical rocking. Contraction duration was assessed as time interval from the electrocardiographic R-(Q-)wave to peak longitudinal strain in each of 17 left ventricular segments. Mechanical dispersion was defined as either the standard deviation of all time intervals (dispersion SD ) or as the difference between the longest and shortest time intervals (dispersion delta ). Patients were followed for cardiac mortality during a median period of 33 months. Mechanical dyssynchrony was not associated with survival. More pronounced mechanical dispersion delta was found in patients with dyssynchrony than in those without. In the multivariate regression analysis, patients' functional class, diabetes mellitus and dispersion delta were independently associated with mortality. Mechanical dispersion, but not dyssynchrony, was independently associated with mortality and it may be useful for risk stratification of patients with heart failure (HF) and BBB. Key Messages Mechanical dispersion, measured by strain echocardiography, is associated with poor outcome in heart failure with a severely depressed left ventricular function and bundle branch blocks. Mechanical dispersion may be useful for risk stratification of patients with heart failure and bundle branch blocks.
Pirat, Bahar; McCulloch, Marti L; Zoghbi, William A
2006-09-01
This study sought to demonstrate that a novel speckle-tracking method can be used to assess right ventricular (RV) global and regional systolic function. Fifty-eight patients with pulmonary arterial hypertension (11 men; mean age 53 +/- 14 years) and 19 age-matched controls were studied. Echocardiographic images in apical planes were analyzed by conventional manual tracing for volumes and ejection fractions and by novel software (Axius Velocity Vector Imaging). Myocardial velocity, strain rate, and strain were determined at the basal, mid, and apical segments of the RV free wall and ventricular septum by Velocity Vector Imaging. RV volumes and ejection fractions obtained with manual tracing correlated strongly with the same indexes obtained by the Velocity Vector Imaging method in all subjects (r = 0.95 to 0.98, p < 0.001 for all). Peak systolic myocardial velocities, strain rate, and strain were significantly impaired in patients with pulmonary arterial hypertension compared with controls and were most altered in patients with the most severe pulmonary arterial hypertension (p < 0.05 for all). Pulmonary artery systolic pressure and a Doppler index of pulmonary vascular resistance were independent predictors of RV strain (r = -0.61 and r = -0.65, respectively, p < 0.05 for both). In conclusion, the new automated Velocity Vector Imaging method provides simultaneous quantitation of global and regional RV function that is angle independent and can be applied retrospectively to already stored digital images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Follansbee, W.P.; Curtiss, E.I.; Medsger, T.A. Jr.
1984-01-19
To investigate cardiopulmonary function in progressive systemic sclerosis with diffuse scleroderma, we studied 26 patients with maximal exercise and redistribution thallium scans, rest and exercise radionuclide ventriculography, pulmonary-function testing, and chest roentgenography. Although only 6 patients had clinical evidence of cardiac involvement, 20 had abnormal thallium scans, including 10 with reversible exercise-induced defects and 18 with fixed defects (8 had both). Seven of the 10 patients who had exercise-induced defects and underwent cardiac catheterization had normal coronary angiograms. Mean resting left ventricular ejection fraction and mean resting right ventricular ejection fraction were lower in patients with post-exercise left ventricular thalliummore » defect scores above the median (59 +/- 13 per cent vs. 69 +/- 6 per cent, and 36 +/- 12 per cent vs. 47 +/- 7 per cent, respectively). The authors conclude that in progressive systemic sclerosis with diffuse scleroderma, abnormalities of myocardial perfusion are common and appear to be due to a disturbance of the myocardial microcirculation. Both right and left ventricular dysfunction appear to be related to this circulatory disturbance, suggesting ischemically mediated injury.« less
Can using a peel-away sheath in shunt implantation prevent ventricular catheter obstruction?
Camlar, Mahmut; Ersahin, Yusuf; Ozer, Fusun Demirçivi; Sen, Fatih; Orman, Mehmet
2011-02-01
Shunt obstruction is the most common shunt complication. In 2003, Kehler et al. used peel-away sheath while implanting the ventricular catheter in 20 patients. They found less revision rate in the peel-away sheath group. We aimed to test the efficacy of this technique in cadavers. We used 100 fresh brains obtained from medicolegal autopsies. Posterior parietal and frontal approaches were used to puncture the lateral ventricle in each cerebral hemisphere. The ventricle is punctured with a peel-away sheath system. After the ventricle is reached, the mandarin is retracted and the ventricular catheter is introduced through the opening. The ventricular catheter was removed from the ventricle, the opening at the tip of the ventricular catheter was checked out for obstruction, and the number of patent and plugged openings was recorded. This procedure was repeated four times for each location with and without using peel-away sheath. The control group consisted of the procedures done without using peel-away sheath. The number of the plugged openings in the peel-away sheath group was significantly smaller than the control group. There was no significant difference between the two groups in terms of gender and left and right cerebral hemispheres. The obstruction rate was significantly lower in the posterior parietal approach. Pearson's correlation showed that increasing age was associated with less obstruction rate. Peel-away sheath decreases the number of plugged openings of the ventricular catheter. A clinical cooperative study is needed to prove that a peel-away sheath should be included in the ventricular shunt systems in the market.
Matsumoto, M; Hanrath, P; Kremer, P; Tams, C; Langenstein, B A; Schlüter, M; Weiter, R; Bleifeld, W
1982-01-01
In order to evaluate left ventricular function during dynamic exercise transoesophageal M-mode recordings of the left ventricle were carried out with a newly developed transducer gastroscope system. Twelve healthy subjects performed a graded supine bicycle exercise test. Stable and good quality images of the left ventricle at rest and during exercise at different steps up to a maximum workload of 100 watts were obtained in all patients. Isotonic maximum exercise resulted in a significant increase in fractional shortening of the left ventricle, peak shortening rate, and peak lengthening rate of the left ventricular minor axis. Left ventricular end-diastolic dimension decreased significantly. With increasing workload the pressure rate product increased significantly. It is concluded that transoesophageal M-mode echocardiography is a useful method of evaluating left ventricular performance during dynamic exercise. Images PMID:7082515
Marcella, J J; Ursell, P C; Goldberger, M; Lovejoy, W; Fenoglio, J J; Weiss, M B
1983-08-01
Kawasaki syndrome, an acute systemic inflammatory illness of unknown origin usually affecting children, may develop into a serious illness complicated by coronary artery aneurysms or myocarditis. This report describes an adult with Kawasaki syndrome studied by right ventricular endomyocardial biopsy and cardiac catheterization during the acute and recovery phases of illness. The initial biopsy specimen showed acute myocarditis and was associated with hemodynamic evidence of biventricular dysfunction, a severely depressed left ventricular ejection fraction and global hypokinesia. With time, there was spontaneous and rapid resolution of the inflammatory cell infiltrate with concurrent return to normal myocardial function. Right ventricular endomyocardial biopsy studies early in the course of the cardiac disease associated with Kawasaki syndrome may correlate with ventricular function and may be useful for monitoring immunosuppressive therapy in patients with this syndrome.
38 CFR 4.97 - Schedule of ratings-respiratory system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pulmonale (right heart failure), or; right ventricular hypertrophy, or; pulmonary hypertension (shown by... hypertension (shown by Echo or cardiac catheterization), or; episode(s) of acute respiratory failure, or...; cor pulmonale (right heart failure), or; right ventricular hypertrophy, or; pulmonary hypertension...
38 CFR 4.97 - Schedule of ratings-respiratory system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... pulmonale (right heart failure), or; right ventricular hypertrophy, or; pulmonary hypertension (shown by... hypertension (shown by Echo or cardiac catheterization), or; episode(s) of acute respiratory failure, or...; cor pulmonale (right heart failure), or; right ventricular hypertrophy, or; pulmonary hypertension...
38 CFR 4.97 - Schedule of ratings-respiratory system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... pulmonale (right heart failure), or; right ventricular hypertrophy, or; pulmonary hypertension (shown by... hypertension (shown by Echo or cardiac catheterization), or; episode(s) of acute respiratory failure, or...; cor pulmonale (right heart failure), or; right ventricular hypertrophy, or; pulmonary hypertension...
38 CFR 4.97 - Schedule of ratings-respiratory system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... pulmonale (right heart failure), or; right ventricular hypertrophy, or; pulmonary hypertension (shown by... hypertension (shown by Echo or cardiac catheterization), or; episode(s) of acute respiratory failure, or...; cor pulmonale (right heart failure), or; right ventricular hypertrophy, or; pulmonary hypertension...
38 CFR 4.97 - Schedule of ratings-respiratory system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... pulmonale (right heart failure), or; right ventricular hypertrophy, or; pulmonary hypertension (shown by... hypertension (shown by Echo or cardiac catheterization), or; episode(s) of acute respiratory failure, or...; cor pulmonale (right heart failure), or; right ventricular hypertrophy, or; pulmonary hypertension...
Blancas Gómez-Casero, Rafael; Quintana Díaz, Manuel; Chana García, Miriam; Martín Parra, Carmen; López Matamala, Blanca; Estébanez Montiel, Belén; Ballesteros Ortega, Daniel; Martínez González, Oscar; Vigil Escribano, Dolores; Prieto Valderrey, Francisca; Marina Martínez, Luis; Castro Gallego, Olmos
2014-04-07
The frequency of left ventricular failure (LVF) in the early stages of non-ST-segment elevation acute coronary syndrome (NSTE ACS) has not been described so far. The objective of this study is to describe for the first time the frequency of LVF in the early course of NSTE ACS and to assess its association with other interventions. Observational prospective cohort multicenter study in intensive and coronary care units (ICCU). Patients with NSTE ACS admitted within 24h after onset were included. Main outcome was the occurrence of LVF. We evaluated the association between LVF and clinical and therapeutic variables. LVF occurred in 15.6% of patients. Coronary angiography (CA) during admission to the ICCU was a protective variable against the main outcome, performed before 72h (odds ratio [OR] 0.47; 95% confidence interval [95% CI] 0.25-0.89; P=.022) and later (OR 0,39; 95% CI 0,15-0,98; P=.044). The administration of beta-blockers was a protective variable against the occurrence of LVF (OR 0,54; 95% CI 0,32-0,87; P=.013). Patients receiving acetylsalicylic acid before admission to the ICCU had a higher risk of developing LVF (OR 1.74; 95% CI 1.06-2.86; P=.028). Age was also a factor of risk for LVF (OR 1.02; 95% CI 1.00-1.05; P=.032). CA and beta-blockers can decrease the occurrence of LVF. The association between previous administration of acetylsalicylic acid and age with the occurrence of LVF may reflect long-standing cardiovascular disease. Copyright © 2012 Elsevier España, S.L. All rights reserved.
[Effect of urapidil combined with phentolamine on hypertension during extracorporeal circulation].
Wang, Fangjun; Chen, Bin; Liu, Yang; Tu, Faping
2014-08-01
To study the effect of urapidil combined with phentolamine in the management of hypertension during extracorporeal circulation. Ninety patients undergoing aortic and mitral valve replacement were randomly divided into 3 equal groups to receive treatment with phentolamine (group A), urapidil (group B), or both (group C) during extracorporeal circulation. The mean arterial pressure (MAP) before and after drug administration, time interval of two administrations, spontaneous recovery of heart beat after aorta unclamping, ventricular arrhythmia, changes of ST-segment 1 min after the recovery of heart beat, ante-parallel cycle time, aorta clamping time, post-parallel cycle time, dopamine dose after cardiac resuscitation, and perioperative changes of plasma TNF-α and IL-6 levels were recorded. There was no significant difference in MAP between the 3 groups before or after hypotensive drug administration (P>0.05). The time interval of two hypotensive drug administrations was longer in group C than in groups A and B (P<0.05). The incidence of spontaneous recovery of heart beat after aorta unclamping, incidence of ventricular arrhythmia, changes of ST-segment 1 min after the recovery of heart beat, ante-parallel cycle time, aorta clamping time, and post-parallel cycle time were all comparable between the 3 groups. The dose of dopamine administered after cardiac resuscitation was significantly larger in group B than in groups A or group C (P<0.05). The plasma levels of TNF-α and IL-6 were significantly increased after CPB and after the operation in all the groups, but were lowed in group C than in groups A and B at the end of CPB and at 2 h and 12 after the operation. Urapidil combined with phentolamine can control hypertension during extracorporeal circulation without causing hypotension.
Feasibility of high-resolution quantitative perfusion analysis in patients with heart failure.
Sammut, Eva; Zarinabad, Niloufar; Wesolowski, Roman; Morton, Geraint; Chen, Zhong; Sohal, Manav; Carr-White, Gerry; Razavi, Reza; Chiribiri, Amedeo
2015-02-12
Cardiac magnetic resonance (CMR) is playing an expanding role in the assessment of patients with heart failure (HF). The assessment of myocardial perfusion status in HF can be challenging due to left ventricular (LV) remodelling and wall thinning, coexistent scar and respiratory artefacts. The aim of this study was to assess the feasibility of quantitative CMR myocardial perfusion analysis in patients with HF. A group of 58 patients with heart failure (HF; left ventricular ejection fraction, LVEF ≤ 50%) and 33 patients with normal LVEF (LVEF >50%), referred for suspected coronary artery disease, were studied. All subjects underwent quantitative first-pass stress perfusion imaging using adenosine according to standard acquisition protocols. The feasibility of quantitative perfusion analysis was then assessed using high-resolution, 3 T kt perfusion and voxel-wise Fermi deconvolution. 30/58 (52%) subjects in the HF group had underlying ischaemic aetiology. Perfusion abnormalities were seen amongst patients with ischaemic HF and patients with normal LV function. No regional perfusion defect was observed in the non-ischaemic HF group. Good agreement was found between visual and quantitative analysis across all groups. Absolute stress perfusion rate, myocardial perfusion reserve (MPR) and endocardial-epicardial MPR ratio identified areas with abnormal perfusion in the ischaemic HF group (p = 0.02; p = 0.04; p = 0.02, respectively). In the Normal LV group, MPR and endocardial-epicardial MPR ratio were able to distinguish between normal and abnormal segments (p = 0.04; p = 0.02 respectively). No significant differences of absolute stress perfusion rate or MPR were observed comparing visually normal segments amongst groups. Our results demonstrate the feasibility of high-resolution voxel-wise perfusion assessment in patients with HF.
Biteker, Murat; Duman, Dursun; Tekkeşin, Ahmet Ilker
2012-08-01
The utility of routine preoperative electrocardiography (ECG) for assessing perioperative cardiovascular risk in patients undergoing noncardiac, nonvascular surgery (NCNVS) is unclear. There would be an association between preoperative ECG and perioperative cardiovascular outcomes in patients undergoing NCNVS. A total of 660 patients undergoing NCNVS were prospectively evaluated. Patients age >18 years who underwent an elective, nonday case, open surgical procedure were enrolled. Troponin I concentrations and 12-lead ECG were evaluated the day before surgery, immediately after surgery, and on the first 5 postoperative days. Preoperative ECG showing atrial fibrillation, left or right bundle branch block, left ventricular hypertrophy, frequent premature ventricular complexes, pacemaker rhythm, Q-wave, ST-segment changes, or sinus tachycardia or bradycardia were classified as abnormal. The patients were followed up during hospitalization and were evaluated for the presence of perioperative cardiovascular events (PCE). Eighty patients (12.1%) experienced PCE. Patients with abnormal ECG findings had a greater incidence of PCE than those with normal ECG results (16% vs 6.4%; P < 0.001). Mean QTc interval was significantly longer in the patients who had PCE (436.6 ± 31.4 vs 413.3 ± 16.7 ms; P < 0.001). Univariate analysis showed a significant association between preoperative atrial fibrillation, pacemaker rhythm, ST-segment changes, QTc prolongation, and in-hospital PCE. However, only QTc prolongation (odds ratio: 1.15, 95% confidence interval: 1.06-1.2, P < 0.001) was an independent predictor of PCE according to the multivariate analysis. Every 10-ms increase in QTc interval was related to a 13% increase for PCE. Prolongation of the QTc interval on the preoperative ECG was related with PCE in patients undergoing NCNVS. © 2011 Wiley Periodicals, Inc.
Nascimento, Francisco O; Yang, Solomon; Larrauri-Reyes, Maiteder; Pineda, Andres M; Cornielle, Vertilio; Santana, Orlando; Heimowitz, Todd B; Stone, Gregg W; Beohar, Nirat
2014-02-01
The presentation of stress cardiomyopathy (SC) with nonobstructive coronary artery disease mimics that of ST-segment elevation myocardial infarction (STEMI) due to coronary occlusion. No single parameter has been successful in differentiating the 2 entities. We thus sought to develop a noninvasive clinical tool to discriminate between these 2 conditions. We retrospectively reviewed 59 consecutive cases of SC at our institution from July 2005 through June 2011 and compared those with 60 consecutives cases of angiographically confirmed STEMI treated with primary percutaneous coronary intervention in the same period. All patients underwent acute echocardiography, and the peak troponin I level was determined. The troponin-ejection fraction product (TEFP) was derived by multiplying the peak troponin I level and the echocardiographically derived left ventricular ejection fraction. Comparing the SC and STEMI groups, the mean left ventricular ejection fraction at the time of presentation was 30 ± 9% versus 44 ± 11%, respectively (p <0.001), and the peak troponin I was 7.6 ± 18 versus 102.2 ± 110.3 ng/dl, respectively (p <0.001). The mean TEFP was thus 182 ± 380 and 4,088 ± 4,244 for the SC and STEMI groups, respectively (p <0.001). Receiver operating characteristic curve analysis showed that a TEFP value ≥250 had a sensitivity of 95%, a specificity of 87%, a negative predictive value of 94%, a positive predictive value of 88%, and an overall accuracy of 91% to differentiate a true STEMI from SC (C-statistic 0.91 ± 0.02, p <0.001). In conclusion, for patients not undergoing emergent angiography, the TEFP may be used with high accuracy to differentiate SC with nonobstructive coronary artery disease from true STEMI due to coronary occlusion. Copyright © 2014 Elsevier Inc. All rights reserved.
Marcella, J J; Nichols, A B; Johnson, L L; Owen, J; Reison, D S; Kaplan, K L; Cannon, P J
1983-05-01
The hypothesis that exercise-induced myocardial ischemia is associated with abnormal platelet activation and fibrin formation or dissolution was tested in patients with coronary artery disease undergoing upright bicycle stress testing. In vivo platelet activation was assessed by radioimmunoassay of platelet factor 4, beta-thrombo-globulin and thromboxane B2. In vivo fibrin formation was assessed by radioimmunoassay of fibrinopeptide A, and fibrinolysis was assessed by radioimmunoassay of thrombin-increasable fibrinopeptide B which reflects plasmin cleavage of fibrin I. Peripheral venous concentrations of these substances were measured in 10 normal subjects and 13 patients with coronary artery disease at rest and during symptom-limited peak exercise. Platelet factor 4, beta-thromboglobulin and thromboxane B2 concentrations were correlated with rest and exercise catecholamine concentrations to determine if exercise-induced elevation of norepinephrine and epinephrine enhances platelet activation. Left ventricular end-diastolic and end-systolic volumes, ejection fraction and segmental wall motion were measured at rest and during peak exercise by first pass radionuclide angiography. All patients with coronary artery disease had documented exercise-induced myocardial ischemia manifested by angina pectoris, ischemic electrocardiographic changes, left ventricular segmental dyssynergy and a reduction in ejection fraction. Rest and peak exercise plasma concentrations were not significantly different for platelet factor 4, beta-thromboglobulin, thromboxane B2, fibrinopeptide A and thrombin-increasable fibrinopeptide B. Peripheral venous concentrations of norepinephrine and epinephrine increased significantly (p less than 0.001) in both groups of patients. The elevated catecholamine levels did not lead to detectable platelet activation. This study demonstrates that enhanced platelet activation, thromboxane release and fibrin formation or dissolution are not detectable in peripheral venous blood of patients with coronary disease during exercise-induced myocardial ischemia.
Ozawa, Koya; Funabashi, Nobusada; Nishi, Takeshi; Takahara, Masayuki; Fujimoto, Yoshihide; Kamata, Tomoko; Kobayashi, Yoshio
2016-08-15
This study evaluated the post-systolic strain index (PSI), and the time interval between aortic valve closure (AVC) and regional peak longitudinal strain (PLS), measured by transthoracic echocardiography (TTE), for detection of left ventricular (LV) myocardial ischemic segments confirmed by invasive fractional flow reserve (FFR). 39 stable patients (32 males; 65.8±11.9years) with 46 coronary arteries at ≥50% stenosis on invasive coronary angiography underwent 2D speckle tracking TTE (Vivid E9, GE Healthcare) and invasive FFR measurements. PSI, AVC and regional PLS in each LV segment were calculated. FFR ≤0.80 was detected in 27 LV segments. There were no significant differences between segments supplied by FFR ≤0.80 and FFR >0.80 vessels in either PSI or the time interval between AVC and regional PLS. To identify LV segments±FFR ≤0.80, the receiver operator characteristic (ROC) curves for PSI, and the time interval between AVC and regional PLS had areas under the curve (AUC) values of 0.58 and 0.57, respectively, with best cut-off points of 12% (sensitivity 70.4%, specificity 57.9%) and 88ms (sensitivity 70.4%, specificity 52.6%), respectively, but the AUCs were not statistically significant. In stable coronary artery disease patients with ≥50% coronary artery stenosis, measurement of PSI, and the time interval between AVC and regional PLS, on resting TTE, enabled the identification of LV segments with FFR ≤0.80 using each appropriate threshold for PSI, and the time interval between AVC and regional PLS, with reasonable diagnostic accuracy. However, the AUC values were not statistically significant. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Zhang, Xiaoyan; Liu, Zhan-Qiu; Singh, Dara; Wehner, Gregory J; Powell, David K; Campbell, Kenneth S; Fornwalt, Brandon K; Wenk, Jonathan F
2017-08-01
Rat models have assumed an increasingly important role in cardiac research. However, a detailed profile of regional cardiac mechanics, such as strains and torsion, is lacking for rats. We hypothesized that healthy rat left ventricles (LVs) exhibit regional differences in cardiac mechanics, which are part of normal function. In this study, images of the LV were obtained with 3D cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance in 10 healthy rats. To evaluate regional cardiac mechanics, the LV was divided into basal, mid-ventricular, and apical regions. The myocardium at the mid-LV was further partitioned into four wall segments (i.e. septal, inferior, lateral, and anterior) and three transmural layers (i.e. sub-endocardium, mid-myocardium, and sub-epicardium). The six Lagrangian strain components (i.e. E rr , E cc , E ll , E cl , E rl , and E cr ) were computed from the 3D displacement field and averaged within each region of interest. Torsion was quantified using the circumferential-longitudinal shear angle. While peak systolic E cl differed between the mid-ventricle and apex, the other five components of peak systolic strain were similar across the base, mid-ventricle, and apex. In the mid-LV myocardium, E cc decreased gradually from the sub-endocardial to the sub-epicardial layer. E ll demonstrated significant differences between the four wall segments, with the largest magnitude in the inferior segment. E rr was uniform among the four wall segments. E cl varied along the transmural direction and among wall segments, whereas E rl differed only among the wall segments. E rc was not associated with significant variations. Torsion also varied along the transmural direction and among wall segments. These results provide fundamental insights into the regional contractile function of healthy rat hearts, and form the foundation for future studies on regional changes induced by disease or treatments. Copyright © 2017 John Wiley & Sons, Ltd.
Marcantoni, Lina; Toselli, Tiziano; Urso, Giulia; Pratola, Claudio; Ceconi, Claudio; Bertini, Matteo
2015-11-01
In the last decade, there has been an exponential increase in cardioverter-defibrillator (ICD) implants. Remote monitoring systems, allow daily follow-ups of patients with ICD. To evaluate the impact of remote monitoring on the management of cardiovascular events associated with supraventricular and ventricular arrhythmias during long-term follow-up. A total of 207 patients undergoing ICD implantation/replacement were enrolled: 79 patients received remote monitoring systems and were followed up every 12 months, and 128 patients were followed up conventionally every 6 months. All patients were followed up and monitored for the occurrence of supraventricular and ventricular arrhythmia-related cardiovascular events (ICD shocks and/or hospitalizations). During a median follow-up of 842 days (interquartile range 476-1288 days), 32 (15.5%) patients experienced supraventricular arrhythmia-related events and 51 (24.6%) patients experienced ventricular arrhythmia-related events. Remote monitoring had a significant role in the reduction of supraventricular arrhythmia-related events, but it had no effect on ventricular arrhythmia-related events. In multivariable analysis, remote monitoring remained as an independent protective factor, reducing the risk of supraventricular arrhythmia-related events of 67% [hazard ratio, 0.33; 95% confidence interval (CI), 0.13-0.82; P = 0.017]. Remote monitoring systems improved outcomes in patients with supraventricular arrhythmias by reducing the risk of cardiovascular events, but no benefits were observed in patients with ventricular arrhythmias.
Reverse or inverted apical ballooning in a case of refeeding syndrome
Robles, Pablo; Monedero, Isabel; Rubio, Amador; Botas, Javier
2015-01-01
Takotsubo cardiomyopathy is characterized by the development of transient left ventricular regional wall motion abnormalities, in the absence of significant coronary artery obstruction. This syndrome usually occurs in women and is frequently associated with an intense emotional or physical stress. It usually involves apical segments, but in the recent years atypical forms have been described. Inverted or reverse Takotsubo is a variant in which the basal and midventricular segments are hypokinetic, sparing contractile function of the apex. In this report we describe the case of a 54-year-old woman, with chronic malnutrition, initially admitted because of hypoglycemia and severe electrolyte disturbance due to a refeeding syndrome. Within the next hours she experienced acute cardiac symptoms and developed heart failure with low cardiac output. Electrocardiogram (ECG), elevation of troponin and echocardiographic findings were consistent with inverted Takotsubo cardiomyopathy. To the best of our knowledge, this is the first incidence reported of inverted Takotsubo triggered by refeeding syndrome. PMID:26131342
Reverse or inverted apical ballooning in a case of refeeding syndrome.
Robles, Pablo; Monedero, Isabel; Rubio, Amador; Botas, Javier
2015-06-26
Takotsubo cardiomyopathy is characterized by the development of transient left ventricular regional wall motion abnormalities, in the absence of significant coronary artery obstruction. This syndrome usually occurs in women and is frequently associated with an intense emotional or physical stress. It usually involves apical segments, but in the recent years atypical forms have been described. Inverted or reverse Takotsubo is a variant in which the basal and midventricular segments are hypokinetic, sparing contractile function of the apex. In this report we describe the case of a 54-year-old woman, with chronic malnutrition, initially admitted because of hypoglycemia and severe electrolyte disturbance due to a refeeding syndrome. Within the next hours she experienced acute cardiac symptoms and developed heart failure with low cardiac output. Electrocardiogram (ECG), elevation of troponin and echocardiographic findings were consistent with inverted Takotsubo cardiomyopathy. To the best of our knowledge, this is the first incidence reported of inverted Takotsubo triggered by refeeding syndrome.
NASA Astrophysics Data System (ADS)
Tobon-Gomez, C.; Bijnens, B. H.; Huguet, M.; Sukno, F.; Moragas, G.; Frangi, A. F.
2009-02-01
Gated single photon emission tomography (gSPECT) is a well-established technique used routinely in clinical practice. It can be employed to evaluate global left ventricular (LV) function of a patient. The purpose of this study is to assess LV systolic and diastolic function from gSPECT datasets in comparison with cardiac magnetic resonance imaging (CMR) measurements. This is achieved by applying our recently implemented 3D active shape model (3D-ASM) segmentation approach for gSPECT studies. This methodology allows for generation of 3D LV meshes for all cardiac phases, providing volume time curves and filling rate curves. Both systolic and diastolic functional parameters can be derived from these curves for an assessment of patient condition even at early stages of LV dysfunction. Agreement of functional parameters, with respect to CMR measurements, were analyzed by means of Bland-Altman plots. The analysis included subjects presenting either LV hypertrophy, dilation or myocardial infarction.
Evaluation of wireless stimulation of the endocardium, WiSE, technology for treatment heart failure.
Seifert, M; Butter, C
2016-06-01
There are several unsolved limitations in delivering cardiac resynchronization therapy. 30-40% of patients fail to have any clinical benefit after 6 months caused by different reasons. Endocardial stimulation rather than conventional epicardial pacing has been shown to: be more physiologically, improve electrical stimulation of the left ventricular, give less dispersion of repolarisation and result in better resynchronization. The Wireless Cardiac Stimulation in Left Ventricle, WiCS-LV, system provides an option for wireless, left ventricular endocardial pacing triggered from a conventional right ventricular pacing spike from a co-implant. Expert commentary: The feasibility of the WiCS-LV system has been successfully demonstrated in a population of failed cardiac resynchronization patients, either failed implantation procedure of a conventional system, non-responder to conventional therapy or upgrade from pacemaker or defibrillator, where a conventional system was not an option. WiCS-LV is innovative technology with promising safety, performance and preliminary efficacy.
Cardinal, René; Pagé, Pierre; Vermeulen, Michel; Ardell, Jeffrey L; Armour, J Andrew
2009-01-28
Ganglionated plexuses (GPs) are major constituents of the intrinsic cardiac nervous system, the final common integrator of regional cardiac control. We hypothesized that nicotinic stimulation of individual GPs exerts divergent regional influences, affecting atrial as well as ventricular functions. In 22 anesthetized canines, unipolar electrograms were recorded from 127 atrial and 127 ventricular epicardial loci during nicotine injection (100 mcg in 0.1 ml) into either the 1) right atrial (RA), 2) dorsal atrial, 3) left atrial, 4) inferior vena cava-inferior left atrial, 5) right ventricular, 6) ventral septal ventricular or 7) cranial medial ventricular (CMV) GP. In addition to sinus and AV nodal function, neural effects on atrial and ventricular repolarization were identified as changes in the area subtended by unipolar recordings under basal conditions and at maximum neurally-induced effects. Animals were studied with intact AV node or following ablation to achieve ventricular rate control. Atrial rate was affected in response to stimulation of all 7 GPs with an incidence of 50-95% of the animals among the different GPs. AV conduction was affected following stimulation of 6/7 GP with an incidence of 22-75% among GPs. Atrial and ventricular repolarization properties were affected by atrial as well as ventricular GP stimulation. Distinct regional patterns of repolarization changes were identified in response to stimulation of individual GPs. RAGP predominantly affected the RA and posterior right ventricular walls whereas CMVGP elicited biatrial and biventricular repolarization changes. Spatially divergent and overlapping cardiac regions are affected in response to nicotinic stimulation of neurons in individual GPs.
Moeskops, Pim; de Bresser, Jeroen; Kuijf, Hugo J; Mendrik, Adriënne M; Biessels, Geert Jan; Pluim, Josien P W; Išgum, Ivana
2018-01-01
Automatic segmentation of brain tissues and white matter hyperintensities of presumed vascular origin (WMH) in MRI of older patients is widely described in the literature. Although brain abnormalities and motion artefacts are common in this age group, most segmentation methods are not evaluated in a setting that includes these items. In the present study, our tissue segmentation method for brain MRI was extended and evaluated for additional WMH segmentation. Furthermore, our method was evaluated in two large cohorts with a realistic variation in brain abnormalities and motion artefacts. The method uses a multi-scale convolutional neural network with a T 1 -weighted image, a T 2 -weighted fluid attenuated inversion recovery (FLAIR) image and a T 1 -weighted inversion recovery (IR) image as input. The method automatically segments white matter (WM), cortical grey matter (cGM), basal ganglia and thalami (BGT), cerebellum (CB), brain stem (BS), lateral ventricular cerebrospinal fluid (lvCSF), peripheral cerebrospinal fluid (pCSF), and WMH. Our method was evaluated quantitatively with images publicly available from the MRBrainS13 challenge ( n = 20), quantitatively and qualitatively in relatively healthy older subjects ( n = 96), and qualitatively in patients from a memory clinic ( n = 110). The method can accurately segment WMH (Overall Dice coefficient in the MRBrainS13 data of 0.67) without compromising performance for tissue segmentations (Overall Dice coefficients in the MRBrainS13 data of 0.87 for WM, 0.85 for cGM, 0.82 for BGT, 0.93 for CB, 0.92 for BS, 0.93 for lvCSF, 0.76 for pCSF). Furthermore, the automatic WMH volumes showed a high correlation with manual WMH volumes (Spearman's ρ = 0.83 for relatively healthy older subjects). In both cohorts, our method produced reliable segmentations (as determined by a human observer) in most images (relatively healthy/memory clinic: tissues 88%/77% reliable, WMH 85%/84% reliable) despite various degrees of brain abnormalities and motion artefacts. In conclusion, this study shows that a convolutional neural network-based segmentation method can accurately segment brain tissues and WMH in MR images of older patients with varying degrees of brain abnormalities and motion artefacts.
Raman, Ajay Sundara; Shabari, Farshad Raissi; Kar, Biswajit; Loyalka, Pranav; Hariharan, Ramesh
2016-04-01
The use of subcutaneous implantable cardioverter-defibrillators is a novel option for preventing arrhythmia-mediated cardiac death in patients who are at risk of endovascular-device infection or in whom venous access is difficult. However, the potential for electromagnetic interference between subcutaneous defibrillators and left ventricular assist devices is largely unknown. We report the case of a 24-year-old man in whom we observed no electromagnetic interference between a subcutaneous implanted cardioverter-defibrillator and a HeartMate II Left Ventricular Assist System, at 3 different pump speeds. To our knowledge, this is the first report of such findings in this circumstance.
Raman, Ajay Sundara; Kar, Biswajit; Loyalka, Pranav; Hariharan, Ramesh
2016-01-01
The use of subcutaneous implantable cardioverter-defibrillators is a novel option for preventing arrhythmia-mediated cardiac death in patients who are at risk of endovascular-device infection or in whom venous access is difficult. However, the potential for electromagnetic interference between subcutaneous defibrillators and left ventricular assist devices is largely unknown. We report the case of a 24-year-old man in whom we observed no electromagnetic interference between a subcutaneous implanted cardioverter-defibrillator and a HeartMate II Left Ventricular Assist System, at 3 different pump speeds. To our knowledge, this is the first report of such findings in this circumstance. PMID:27127441
Akkaya, Mehmet; Bacaksiz, Ahmet; Tasal, Abdurrahman; Sevgili, Emrah
2013-01-01
Noncompaction of the ventricular myocardium is a rare congenital heart disease, presumably caused by the intrauterine arrest of the myocardial compaction process at the beginning of fetal development. It could remain asymptomatic or manifest with congestive heart failure, arrhythmias, and systemic thromboemboli. Here we report a 55-year-old man who was admitted to hospital with chest pain and dyspnea, whose further evaluation revealed left ventricular noncompaction cardiomyopathy accompanying myocardial bridging and stenosis of the right coronary artery. PMID:24570713
NASA Technical Reports Server (NTRS)
Koenig, S. C.; Ludwig, D. A.; Reister, C.; Fanton, J. W.; Ewert, D.; Convertino, V. A.
2001-01-01
Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.
Measurement of left ventricular mass in vivo using gated nuclear magnetic resonance imaging.
Florentine, M S; Grosskreutz, C L; Chang, W; Hartnett, J A; Dunn, V D; Ehrhardt, J C; Fleagle, S R; Collins, S M; Marcus, M L; Skorton, D J
1986-07-01
Alterations of left ventricular mass occur in a variety of congenital and acquired heart diseases. In vivo determination of left ventricular mass, using several different techniques, has been previously reported. Problems inherent in some previous methods include the use of ionizing radiation, complicated geometric assumptions and invasive techniques. We tested the ability of gated nuclear magnetic resonance imaging to determine in vivo left ventricular mass in animals. By studying both dogs (n = 9) and cats (n = 2) of various sizes, a broad range of left ventricular mass (7 to 133 g) was examined. With a 0.5 tesla superconducting nuclear magnetic resonance imaging system the left ventricle was imaged in the transaxial plane and multiple adjacent 10 mm thick slices were obtained. Endocardial and epicardial edges were manually traced in each computer-displayed image. The wall area of each image was determined by computer and the areas were summed and multiplied by the slice thickness and the specific gravity of muscle, providing calculated left ventricular mass. Calculated left ventricular mass was compared with actual postmortem left ventricular mass using linear regression analysis. An excellent relation between calculated and actual mass was found (r = 0.95; SEE = 13.1 g; regression equation: magnetic resonance mass = 0.95 X actual mass + 14.8 g). Intraobserver and interobserver reproducibility were also excellent (r = 0.99). Thus, gated nuclear magnetic resonance imaging can accurately determine in vivo left ventricular mass in anesthetized animals.
Ventricular dysfunction in type 1 myotonic dystrophy: electrical, mechanical, or both?
Lindqvist, P; Mörner, S; Olofsson, B O; Backman, C; Lundblad, D; Forsberg, H; Henein, M Y
2010-09-03
Myotonic dystrophy type 1 (DM1) is a systemic disease which affects the heart and may be a cause of sudden death. Conduction disturbances are the major cardiac abnormalities seen in this condition. We sought to assess electrical and mechanical cardiac functions to identify abnormalities that might explain sudden cardiac death in DM1. Thirty six patients with DM1 and 16 controls were studied using echocardiography including myocardial Doppler. ECG recordings were also obtained. Left ventricular (LV) dimensions were maintained but systolic function was reduced (p<0.001), including stroke volume (p<0.05). LV segmental myocardial isovolumic contraction time was prolonged (p<0.001) and correlated with PR interval (p<0.001). Isovolumic relaxation time was prolonged (p<0.05) and filling time was reduced (p<0.001). LV cavity was significantly asynchronous demonstrated by prolonged total isovolumic time (t-IVT) (p<0.001), high Tei index (p<0.001) and low ejection index (p<0.001). Right ventricular (RV) strain was reduced (p<0.001) as were its systolic and diastolic velocities (p<0.05 for both). 22/36 patients had prolonged LV t-IVT>12.3 s/min (upper 95% normal CI), 13 of whom had PR≥200 ms, 11 had QRS duration>120 ms (5 had combined abnormality) and the remaining 5 had neither. Over the 3 years follow up 10 patients had events, 6 of them cardiac. t-IVT was prolonged in 5/6 patients, PR interval in 4 and QRS duration in one. In DM1 patients, LV conventional measurements are modestly impaired but cardiac time relations suggest marked asynchronous cavity function. Although our findings were primarily explained on the basis of long PR interval or broad QRS duration a minority presented an evidence for myocardial cause of asynchrony rather than electrical. Early identification of such abnormalities may guide towards a need for additional electrical resynchronization therapy which may improve survival in a way similar to what has been shown in heart failure trials. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
The pathophysiology of heart failure.
Kemp, Clinton D; Conte, John V
2012-01-01
Heart failure is a clinical syndrome that results when the heart is unable to provide sufficient blood flow to meet metabolic requirements or accommodate systemic venous return. This common condition affects over 5 million people in the United States at a cost of $10-38 billion per year. Heart failure results from injury to the myocardium from a variety of causes including ischemic heart disease, hypertension, and diabetes. Less common etiologies include cardiomyopathies, valvular disease, myocarditis, infections, systemic toxins, and cardiotoxic drugs. As the heart fails, patients develop symptoms which include dyspnea from pulmonary congestion, and peripheral edema and ascites from impaired venous return. Constitutional symptoms such as nausea, lack of appetite, and fatigue are also common. There are several compensatory mechanisms that occur as the failing heart attempts to maintain adequate function. These include increasing cardiac output via the Frank-Starling mechanism, increasing ventricular volume and wall thickness through ventricular remodeling, and maintaining tissue perfusion with augmented mean arterial pressure through activation of neurohormonal systems. Although initially beneficial in the early stages of heart failure, all of these compensatory mechanisms eventually lead to a vicious cycle of worsening heart failure. Treatment strategies have been developed based upon the understanding of these compensatory mechanisms. Medical therapy includes diuresis, suppression of the overactive neurohormonal systems, and augmentation of contractility. Surgical options include ventricular resynchronization therapy, surgical ventricular remodeling, ventricular assist device implantation, and heart transplantation. Despite significant understanding of the underlying pathophysiological mechanisms in heart failure, this disease causes significant morbidity and carries a 50% 5-year mortality. Copyright © 2012 Elsevier Inc. All rights reserved.
Traumatic Brain Injury-Induced Ependymal Ciliary Loss Decreases Cerebral Spinal Fluid Flow
Xiong, Guoxiang; Elkind, Jaclynn A.; Kundu, Suhali; Smith, Colin J.; Antunes, Marcelo B.; Tamashiro, Edwin; Kofonow, Jennifer M.; Mitala, Christina. M.; Stein, Sherman C.; Grady, M. Sean; Einhorn, Eugene; Cohen, Noam A.
2014-01-01
Abstract Traumatic brain injury (TBI) afflicts up to 2 million people annually in the United States and is the primary cause of death and disability in young adults and children. Previous TBI studies have focused predominantly on the morphological, biochemical, and functional alterations of gray matter structures, such as the hippocampus. However, little attention has been given to the brain ventricular system, despite the fact that altered ventricular function is known to occur in brain pathologies. In the present study, we investigated anatomical and functional alterations to mouse ventricular cilia that result from mild TBI. We demonstrate that TBI causes a dramatic decrease in cilia. Further, using a particle tracking technique, we demonstrate that cerebrospinal fluid flow is diminished, thus potentially negatively affecting waste and nutrient exchange. Interestingly, injury-induced ventricular system pathology resolves completely by 30 days after injury as ependymal cell ciliogenesis restores cilia density to uninjured levels in the affected lateral ventricle. PMID:24749541
Kydd, Anna C; Khan, Fakhar Z; Watson, William D; Pugh, Peter J; Virdee, Munmohan S; Dutka, David P
2014-06-01
This study was conducted to assess the impact of left ventricular (LV) lead position on longer-term survival after cardiac resynchronization therapy (CRT). An optimal LV lead position in CRT is associated with improved clinical outcome. A strategy of speckle-tracking echocardiography can be used to guide the implanter to the site of latest activation and away from segments of low strain amplitude (scar). Long-term, prospective survival data according to LV lead position in CRT are limited. Data from a follow-up registry of 250 consecutive patients receiving CRT between June 2008 and July 2010 were studied. The study population comprised patients recruited to the derivation group and the subsequent TARGET (Targeted Left Ventricular Lead Placement to guide Cardiac Resynchronization Therapy) randomized, controlled trial. Final LV lead position was described, in relation to the pacing site determined by pre-procedure speckle-tracking echocardiography, as optimal (concordant/adjacent) or suboptimal (remote). All-cause mortality was recorded at follow-up. An optimal LV lead position (n = 202) conferred LV remodeling response superior to that of a suboptimal lead position (change in LV end-systolic volume: -24 ± 15% vs. -12 ± 17% [p < 0.001]; change in ejection fraction: +7 ± 8% vs. +4 ± 7% [p = 0.02]). During long-term follow-up (median: 39 months; range: <1 to 61 months), an optimal LV lead position was associated with improved survival (log-rank p = 0.003). A suboptimal LV lead placement independently predicted all-cause mortality (hazard ratio: 1.8; p = 0.024). An optimal LV lead position at the site of latest mechanical activation, avoiding low strain amplitude (scar), was associated with superior CRT response and improved survival that persisted during follow-up. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Sciarra, Luigi; Golia, Paolo; Palamà, Zefferino; Scarà, Antonio; De Ruvo, Ermenegildo; Borrelli, Alessio; Martino, Anna Maria; Minati, Monia; Fagagnini, Alessandro; Tota, Claudia; De Luca, Lucia; Grieco, Domenico; Delise, Pietro; Calò, Leonardo
Left bundle branch block (LBBB) and left axis deviation (LAD) patients may have poor response to resynchronization therapy (CRT). We sought to assess if LBBB and LAD patients show a specific pattern of mechanical asynchrony. CRT candidates with non-ischemic cardiomyopathy and LBBB were categorized as having normal QRS axis (within -30° and +90°) or LAD (within -30° and -90°). Patients underwent tissue Doppler imaging (TDI) to measure time interval between onset of QRS complex and peak systolic velocity in ejection period (Q-peak) at basal segments of septal, inferior, lateral and anterior walls, as expression of local timing of mechanical activation. Thirty patients (mean age 70.6years; 19 males) were included. Mean left ventricular ejection fraction was 0.28±0.06. Mean QRS duration was 172.5±13.9ms. Fifteen patients showed LBBB with LAD (QRS duration 173±14; EF 0.27±0.06). The other 15 patients had LBBB with a normal QRS axis (QRS duration 172±14; EF 0.29±0.05). Among patients with LAD, Q-peak interval was significantly longer at the anterior wall in comparison to each other walls (septal 201±46ms, inferior 242±58ms, lateral 267±45ms, anterior 302±50ms; p<0.0001). Conversely, in patients without LAD Q-peak interval was longer at lateral wall, when compared to each other (septal 228±65ms, inferior 250±64ms, lateral 328±98ms, anterior 291±86ms; p<0.0001). Patients with heart failure, presenting LBBB and LAD, show a specific pattern of ventricular asynchrony, with latest activation at anterior wall. This finding could affect target vessel selection during CRT procedures in these patients. Copyright © 2017 Elsevier Inc. All rights reserved.
Brand, Anna; Bathe, Marny; Oertelt-Prigione, Sabine; Seeland, Ute; Rücke, Mirjam; Regitz-Zagrosek, Vera; Stangl, Karl; Knebel, Fabian; Stangl, Verena; Dreger, Henryk
2018-01-01
The aim of our study was to describe right atrial (RA) and right ventricular (RV) function, assessed by Doppler tissue imaging and 2D speckle tracking echocardiography (2DSTE), in women with signs of early impaired left ventricular diastolic function (DD). In a cross-sectional trial, standard parameters of diastolic and right heart function were investigated in 438 women of the Berlin Female Risk Evaluation (BEFRI) study. In a subset of women, average peak systolic RA strain (RAS), as well as the average peak systolic RV strain of the free wall (RVS free wall) and of all RV segments (average RV strain; RVS Avg), was analyzed using 2DSTE. Compared to women with normal diastolic function (DD0), RAS, RVS free wall and RVS Avg were significantly reduced in DD (43.1% ± 11.9%, -26.7% ± 5.6%, and -23.3% ± 3.5% in DD0; vs 35.1% ± 10.4%, -23.9% ± 5.5%, and -20.6% ± 3.8% in DD; P < .01). Peak RV myocardial velocity (RV-IVV) and acceleration during isovolumetric contraction (RV-IVA) were markedly higher in DD (15.0 ± 3.9 cm/s and 3.1 ± 1.0 m/s² in DD vs 11.9 ± 3.2 cm/s and 2.8 ± 0.8 m/s² in DD0; P < .05). RAS and RV-IVV were significantly associated with DD after adjustment to age, BMI, and left atrial strain in multivariate regression analysis. Systolic right heart function is significantly altered in DD. DTI as well as 2DSTE constitute sensitive echocardiographic tools that enable the diagnosis of impaired right heart mechanics in early-staged DD. © 2017 Wiley Periodicals, Inc.
Haemers, Peter; Sutherland, George; Cikes, Maja; Jakus, Nina; Holemans, Patricia; Sipido, Karin R; Willems, Rik; Claus, Piet
2015-11-01
An acute increase in blood pressure is associated with the occurrence of premature ventricular complexes (PVCs). We aimed to study the timing of these PVCs with respect to afterload-induced changes in myocardial deformation in a controlled, preclinically relevant, novel closed-chest pig model. An acute left ventricular (LV) afterload challenge was induced by partial balloon inflation in the descending aorta, lasting 5-10 heartbeats (8 pigs; 396 inflations). Balloon inflation enhanced the reflected wave (augmentation index 30% ± 8% vs 59% ± 6%; P < .001), increasing systolic central blood pressure by 35% ± 4%. This challenge resulted in a more abrupt LV pressure decline, which was delayed beyond ventricular repolarization (rate of pressure decline 0.16 ± 0.01 mm Hg/s vs 0.27 ± 0.04 mm Hg/ms; P < .001 and interval T-wave to peak pressure 1 ± 12 ms vs 36 ± 9 ms; P = .008), during which the velocity of myocardial shortening at the basal septum increased abruptly (ie, postsystolic shortening) (peak strain rate -0.6 ± 0.5 s(-1) vs -2.5 ± 0.8 s(-1); P < .001). It is exactly at this time of LV pressure decline, with increased postsystolic shortening, and not at peak pressure, that PVCs occur (22% of inflations). These PVCs preferentially occurred at the basal and apical segments. In the same regions, monophasic action potentials demonstrated the appearance of delayed afterdepolarization-like transient depolarizations as origin of PVCs. An acute blood pressure increase results in a more abrupt LV pressure decline, which is delayed after ventricular repolarization. This has a profound effect on myocardial mechanics with enhanced postsystolic shortening. Coincidence with induced transient depolarizations and PVCs provides support for the mechanoelectrical origin of pressure-induced premature beats. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Amoogzar, Hamid; Shakiba, Ali Mohammad; Derakhshan, Dorna; Ajami, Gholamhossein; Cheriki, Sirous; Borzouee, Mohammad; Edraki, Mohammad Reza; Mehdizadegan, Nima
2015-01-01
The aim of this study was to evaluate the left ventricular systolic and diastolic function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure. 21 children (age >6 months old) diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler and tissue Doppler imaging and speckled-derived strain rate echocardiography were done at pre-closure, 1 day (early) and 1 month (late) post-closure. Mean age of the patients (female/male: 1.3) was 17.54 ± 24.7 months with the mean PDA diameter of 3.6 ± 0.8 mm. Systolic measures (ejection fraction, shortening fraction) reduced significantly early after PDA closure (P < 0.05). After 1 month, both improved significantly; ultimately, after 1 month no change was observed in systolic function measures compared with the pre-closure status. Early and late diastolic flow velocities of mitral (E M and A M) reduced considerably in early and late post-closure time (P < 0.05). Both early tissue Doppler early velocity of lateral mitral annulus (E'M) and early to late velocity ratio (E'M/A'M) of lateral mitral annulus decreased significantly (P = 0.02) in early post-closure. After 1 month, E'M increased considerably. (P = 0.01) but E'M/A'M had an insignificant rise (P > 0.05). E M/E'M ratio did not change in early post-closure but it had a considerable reduction in the subsequent month compared with the pre- and early post-closure (P < 0.001 for both occasions). Global and segmental longitudinal strain measures reduced significantly early after PDA closure (P < 0.05) but it improved remarkably in the subsequent month. Transcatheter PDA closure causes a significant decrease in left ventricular performance early after PDA closure which recovers completely within 1 month. Also PDA size can affect post-closure left ventricular function.
Jang, Yongwon; Noh, Hyung Wook; Lee, I B; Jung, Ji-Wook; Song, Yoonseon; Lee, Sooyeul; Kim, Seunghwan
2012-01-01
A patch type embedded cardiac function monitoring system was developed to detect arrhythmias such as PVC (Premature Ventricular Contraction), pause, ventricular fibrillation, and tachy/bradycardia. The overall system is composed of a main module including a dual processor and a Bluetooth telecommunication module. The dual microprocessor strategy minimizes power consumption and size, and guarantees the resources of embedded software programs. The developed software was verified with standard DB, and showed good performance.
Khalafvand, S S; Ng, E Y K; Zhong, L; Hung, T K
2012-08-01
Pulsating blood flow patterns in the left ventricular (LV) were computed for three normal subjects and three patients after myocardial infarction (MI). Cardiac magnetic resonance (MR) images were obtained, segmented and transformed into 25 frames of LV for a computational fluid dynamics (CFD) study. Multi-block structure meshes were generated for 25 frames and 75 intermediate grids. The complete LV cycle was modelled by using ANSYS-CFX 12. The flow patterns and pressure drops in the LV chamber of this study provided some useful information on intra-LV flow patterns with heart diseases. Copyright © 2012 Elsevier Ltd. All rights reserved.
Robust boundary detection of left ventricles on ultrasound images using ASM-level set method.
Zhang, Yaonan; Gao, Yuan; Li, Hong; Teng, Yueyang; Kang, Yan
2015-01-01
Level set method has been widely used in medical image analysis, but it has difficulties when being used in the segmentation of left ventricular (LV) boundaries on echocardiography images because the boundaries are not very distinguish, and the signal-to-noise ratio of echocardiography images is not very high. In this paper, we introduce the Active Shape Model (ASM) into the traditional level set method to enforce shape constraints. It improves the accuracy of boundary detection and makes the evolution more efficient. The experiments conducted on the real cardiac ultrasound image sequences show a positive and promising result.
Cardiac MRI-confirmed mesalamine-induced myocarditis
Baker, William L; Saulsberry, Whitney J; Elliott, Kaitlyn; Parker, Matthew W
2015-01-01
A 38-year-old Caucasian man with a medical history significant for inflammatory bowel disease (IBD) and mesalamine use presented to the emergency department with stabbing, pleuritic, substernal chest pain over the previous 2 days. Findings of leucocytosis, elevated cardiac enzymes and inflammatory markers, T-wave or ST-segment abnormalities and left ventricular systolic dysfunction suggested mesalamine-induced myocarditis. However, a cardiac MRI confirmed the diagnosis. Signs and symptoms improved within days of withdrawal of mesalamine, and initiation of corticosteroids and follow-up studies within the next year were unremarkable. Importantly, the diagnosis of mesalamine-induced myocarditis confirmed via cardiac MRI is a step rarely performed in published cases. PMID:26341161
Lung function and left ventricular hypertrophy in morbidly obese candidates for bariatric surgery
Müller, Paulo de Tarso; Domingos, Hamilton; Patusco, Luiz Armando Pereira; Rapello, Gabriel Victor Guimarães
2015-01-01
Objective: To look for correlations between lung function and cardiac dimension variables in morbidly obese patients, in order to test the hypothesis that the relative size of the small airways is independently correlated with left ventricular hypertrophy. Methods: This was a retrospective study involving 192 medical records containing a clinical protocol employed in candidates for bariatric surgery between January of 2006 and December of 2010. Results: Of the 192 patients evaluated, 39 (10 males and 29 females) met the inclusion criteria. The mean BMI of the patients was 49.2 ± 7.6 kg/m2, and the mean age was 35.5 ± 7.7 years. The FEF25-75/FVC, % correlated significantly with left ventricular posterior wall thickness and relative left ventricular posterior wall thickness, those correlations remaining statistically significant (r = −0.355 and r = −0.349, respectively) after adjustment for weight, gender, and history of systemic arterial hypertension. Stepwise multivariate linear regression analysis showed that FVC and FEV1 were the major determinants of left ventricular mass (in grams or indexed to body surface area). Conclusions: A reduction in the relative size of the small airways appears to be independently correlated with obesity-related cardiac hypertrophy, regardless of factors affecting respiratory mechanics (BMI and weight), gender, or history of systemic arterial hypertension. However, FEV1 and FVC might be important predictors of left ventricular mass in morbidly obese individuals. PMID:26578134
A hemodynamics model to study the collective behavior of the ventricular-arterial system
NASA Astrophysics Data System (ADS)
Lin Wang, Yuh-Ying; Wang, Wei-Kung
2013-01-01
Applying principles from complex systems to study the efficacy of integrative therapies has become a new interest in medical research. We aimed to construct a concise model for the ventricular-arterial (VA) system and to provide a systematic method for exploring its overall behavior. The transportation of blood from the heart to the peripheral arterioles via hydraulic pressure forces was described by a multi-rank model. Parts of the VA system that have strong mutual interactions were combined into a single sub system. Sub systems of four different ranks were characterized. We then applied the multi-rank model to analyze the aortic pressure wave generated by the periodic ventricular blood ejection, the renal pressure in response to the input from the VA system, and the blood flowing from the renal artery to its arterioles. Maintaining the pressure distribution along the main arteries and in all of the organs with the lowest possible ventricular input turned out to be the first principle for the operation of an efficient VA system. By this principle, we pointed out the benefit of some arterial structures in mammals, derived specific regulation rules and deduced some fundamental concepts for healing. The justification of the biomechanics in our model that differed greatly from those in the prevailing models was given. We concluded that the oscillatory motion and the pressure pulse of the arterial system can be analyzed as steady states with resonance behaviors and suggested utilizing this model to construct integrative therapies for diseases correlated with abnormality in blood circulation.
Fukushima, Norihide; Tatsumi, Eisuke; Seguchi, Osamu; Takewa, Yoshiaki; Hamasaki, Toshimitsu; Onda, Kaori; Yamamoto, Haruko; Hayashi, Teruyuki; Fujita, Tomoyuki; Kobayashi, Junjiro
2018-06-08
The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. The purpose of this study (NCVC-BTD_01, National Cerebral and Cardiovascular Center-Bridge to Dicision_01) is to assess the safety and effectiveness of the newly developed extracorporeal continuous-flow ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing (BR16010) use as a bridge-to-decision therapy for patients with severe heart failure or refractory cardiogenic shock. NCVC-BTD_01 is a single-center, single-arm, open-label, exploratory, medical device, investigator-initiated clinical study. It is conducted at the National Cerebral and Cardiovascular Center in Japan. A total of nine patients will be enrolled in the study. The study was planned using Simon's minimax two-stage phase design. The primary endpoint is a composite of survival free of device-related serious adverse events and complications during device support. For left ventricular assistance, withdrawal of a trial device due to cardiac function recovery or exchange to other ventricular assist devices (VADs) for the purpose of bridge to transplantation (BTT) during 30 days after implantation will be considered study successes. For right ventricular assistance, withdrawal of tal device due to right ventricular function recovery within 30 days after implantation will be considered a study success. Secondary objectives include changes in brain natriuretic peptide levels (7 days after implantation of a trial device and the day of withdrawal of a trial device), period of mechanical ventricular support, changes in left ventricular ejection fraction (7 days after implantation of a trial device and the day of withdrawal of a trial device), and changes in left ventricular diastolic dimension (7 days after implantation of a trial device and the day of withdrawal of a trial device). We will disseminate the findings through regional, national, and international conferences and through peer-reviewed journals. UMIN Clinical Trials Registry (UMIN-CTR; R000033243) registered on 8 September 2017.
Ferrari, Gianfranco; Khir, Ashraf W; Fresiello, Libera; Di Molfetta, Arianna; Kozarski, Maciej
2011-09-01
We investigated the effects of the intra-aortic balloon pump (IABP) on endocardial viability ratio (EVR), cardiac output (CO), end-systolic (V(es)) and end-diastolic (V(ed)) ventricular volumes, total coronary blood flow (TCBF), and ventricular energetics (external work [EW], pressure-volume area [PVA]) under different ventricular (E(max) and diastolic stiffness) and circulatory (arterial compliance) parameters. We derived a hybrid model from a computational model, which is based on merging computational and hydraulic submodels. The lumped parameter computational submodel consists of left and right hearts and systemic, pulmonary, and coronary circulations. The hydraulic submodel includes part of the systemic arterial circulation, essentially a silicone rubber tube representing the aorta, which contains a 40-mL IAB. EVR, CO, V(es), and V(ed), TCBF and ventricular energetics (EW, PVA) were analyzed against the ranges of left ventricular E(max) (0.3-0.5-1 mm Hg/cm(3)) and diastolic stiffness V(stiffness) (≈0.08 and ≈0.3 mm Hg/cm(3), obtained by changing diastolic stiffness constant) and systemic arterial compliance (1.8-2.5 cm(3)/mm Hg). All experiments were performed comparing the selected variables before and during IABP assistance. Increasing E(maxl) from 0.5 to 2 mm Hg/cm(3) resulted in IABP assistance producing lower percentage changes in the selected variables. The changes in ventricular diastolic stiffness strongly influence both absolute value of EVR and its variations during IABP (71 and 65% for lower and higher arterial compliance, respectively). V(ed) and V(es) changes are rather small but higher for lower E(max) and higher V(stiffness). Lower E(max) and higher V(stiffness) resulted in higher TCBF and CO during IABP assistance (∼35 and 10%, respectively). The use of this hybrid model allows for testing real devices in realistic, stable, and repeatable circulatory conditions. Specifically, the presented results show that IABP performance is dependent, at least in part, on left ventricular filling, ejection characteristics, and arterial compliance. It is possible in this way to simulate patient-specific conditions and predict the IABP performance at different values of the circulatory or ventricular parameters. Further work is required to study the conditions for heart recovery modeling, baroreceptor controls, and physiological feedbacks. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Cura, Fernando A; Escudero, Alejandro Garcia; Berrocal, Daniel; Mendiz, Oscar; Trivi, Marcelo S; Fernandez, Juan; Palacios, Alejandro; Albertal, Mariano; Piraino, Ruben; Riccitelli, Miguel Angel; Gruberg, Luis; Ballarino, Miguel; Milei, Jose; Baeza, Ricardo; Thierer, Jorge; Grinfeld, Liliana; Krucoff, Mitchell; O'Neill, William; Belardi, Jorge
2007-02-01
Distal embolization may decrease myocardial reperfusion after primary percutaneous coronary intervention (PCI). Nonetheless, results of previous trials assessing the role of distal protection during primary PCI have been controversial. The Protection of Distal Embolization in High-Risk Patients with Acute ST-Segment Elevation Myocardial Infarction Trial (PREMIAR) was a prospective, randomized, controlled study designed to evaluate the role of filter-based distal protection during PCI in patients with acute ST-segment elevation myocardial infarction at high risk of embolic events (including only baseline Thrombolysis In Myocardial Infarction grade 0 to 2 flow). The primary end point was continuous monitoring of ST-segment resolution. Secondary end points included core laboratory analysis of angiographic myocardial blush, ejection fraction measured by cardiac ultrasound, and adverse cardiac events at 6 months. From a total of 194 enrolled patients, 140 subjects were randomized to PCI with or without embolic protection, and 54 were included in a registry arm due to the presence of angiographic exclusion criteria. Baseline characteristics were comparable between arms. The rate of complete ST-segment resolution (>or=70%) at 60 minutes was similar in patients treated with or without distal protection (61.2% vs 60.3%, respectively, p = 0.85). Angiographic myocardial blush (67% vs 70.7%, p = 0.73), in-hospital ejection fraction (47.4 +/- 9.9% vs 45.3 +/- 7.3%, p = 0.29), and combined end point of death, heart failure, or reinfarction at 6 months (14.3% vs 15.7%, p = 0.81) were consistently achieved in a similar proportion in the 2 groups. In conclusion, the use of filter-based distal protection is safe and effectively retrieves debris; however, such use does not translate into an improvement of myocardial reperfusion, left ventricular performance, or clinical outcomes.
Weiss, J M; Simson, P G; Hoffman, L J; Ambrose, M J; Cooper, S; Webster, A
1986-04-01
These studies examined how pharmacological stimulation and blockade of alpha receptors would affect active motor behavior in rats. In experiment I, alpha-2 receptor antagonists (piperoxane, yohimbine) and agonists [clonidine, norepinephrine (NE)] were infused into various locations in the ventricular system of the brain, including the locus coeruleus region, and motor activity was measured. Activity was measured principally in a swim test but spontaneous (ambulatory) activity was also recorded while drugs were being infused. When infused into the locus coeruleus region, small doses of the antagonists piperoxane and yohimbine depressed activity in the swim test while infusion of the agonists clonidine and NE had the opposite effect of stimulating activity. These effects were highly specific to the region of the locus coeruleus, since infusions of these drugs into other nearby locations in the ventricular system or use of larger doses had different, often opposite effects. This was especially true of clonidine and NE which profoundly depressed activity when infused posterior to the locus coeruleus, particularly over the dorsal vagal complex. Infusion of small doses of these drugs into the lateral ventricle had effects similar to infusion into the locus coeruleus region, though less pronounced. Changes in spontaneous motor activity were also observed, but this measure differentiated the groups less well than did the swim test. In experiment II, the predominantly postsynaptic receptor agonists isoproterenol (beta agonist) and phenylephrine (alpha-1 agonist) were infused into the ventricular system. Since infusions of piperoxane and yohimbine into the locus coeruleus that decreased activity in experiment I increase the release of NE by blocking alpha-2 inhibitory receptors on cell bodies and dendrites of the locus coeruleus, experiment II tested whether ventricular infusion of predominantly postsynaptic receptor agonists would also decrease activity in the swim test. Both isoproterenol and phenylephrine produced this effect, but did so selectively with respect to dose and location of infusion in the ventricular system. These findings are consistent with recent results relating to the mechanism that underlies stress-induced depression of active behavior.
Dynamical relations for left ventricular ejection - Flow rate, momentum, force and impulse
NASA Technical Reports Server (NTRS)
Back, L. H.; Selzer, R. H.; Gordon, D. G.; Ledbetter, D. C.; Crawford, D. W.
1984-01-01
An investigation was carried out to quantitatively evaluate left ventricular volume flow rate, momentum, force and impulse derived from application of conservation principles for mass and momentum of blood within the ventricle during the ejection phase. An automated digital image processing system was developed and applied to left ventricular angiograms which are computer processed and analyzed frame by frame to determine the dynamical relations by numerical methods. The initial experience with force and impulse has indicated that neither quantity seemed to be a sensitive indicator of coronary artery disease as evaluated by qualitative angiography for the particular patient group studied. Utilization of the dynamical relations in evaluating human left ventricular performance requires improved means of measurement and interpretation of clinical studies.
Hoover, Donald B.; Shepherd, Angela V.; Southerland, E. Marie; Armour, J. Andrew; Ardell, Jeffrey L.
2008-01-01
While much is known about the influence of ventricular afferent neurons on cardiovascular function in the dog, identification of the neurochemicals transmitting cardiac afferent signals to central neurons is lacking. Accordingly, we identified ventricular afferent neurons in canine dorsal root ganglia (DRG) and nodose ganglia by retrograde labeling after injecting horseradish peroxidase (HRP) into the anterior right and left ventricles. Primary antibodies from three host species were used in immunohistochemical experiments to simultaneously evaluate afferent somata for the presence of HRP and markers for two neurotransmitters. Only a small percentage (2%) of afferent somata were labeled with HRP. About half of the HRP-identified ventricular afferent neurons in T3 DRG also stained for substance P (SP), calcitonin gene-related peptide (CGRP), or neuronal nitric oxide synthase (nNOS), either alone or with two markers colocalized. Ventricular afferent neurons and the general population of T3 DRG neurons showed the same labeling profiles; CGRP (alone or colocalized with SP) being the most common (30–40% of ventricular afferent somata in T3 DRG). About 30% of the ventricular afferent neurons in T2 DRG displayed CGRP immunoreactivity and binding of the putative nociceptive marker IB4. Ventricular afferent neurons of the nodose ganglia were distinct from those in the DRG by having smaller size and lacking immunoreactivity for SP, CGRP, and nNOS. These findings suggest that ventricular sensory information is transferred to the central nervous system by relatively small populations of vagal and spinal afferent neurons and that spinal afferents use a variety of neurotransmitters. PMID:18558516
Change of heart dimensions and function during pregnancy in goats.
Szaluś-Jordanow, Olga; Czopowicz, Michał; Witkowski, Lucjan; Moroz, Agata; Mickiewicz, Marcin; Frymus, Tadeusz; Markowska-Daniel, Iwona; Bagnicka, Emilia; Kaba, Jarosław
2018-03-08
The study aimed to evaluate the effect of pregnancy on heart diameters and function in goats. Transthoracic echocardiography of 12 female dairy goats of two Polish regional breeds was performed. A Mindray M7 diagnostic ultrasound system with Phased Array transducer was used. Simultaneously, electrocardiography was recorded. All animals were examined four times - at mating season, at the end of the first trimester, at the end of the second trimester and just before kidding. Eleven measurements were taken each time: aortic and left atrial diameter (AoD and LAD), right and left ventricular internal diameter in diastole (RVIDd and LVIDd), left ventricular internal diameter in systole (LVIDs), inter-ventricular septum thickness in diastole and systole (IVSd and IVSd) and left ventricular posterior wall in diastole and systole (LVPWd and LVPWs), maximum left and right ventricular outflow tract velocity (RVOT Vmax and LVOT Vmax). Nine consecutive measurements were derived: the ratio of the left atrial diameter to the aortic diameter (AoD/LAD), left ventricular fractional shortening (FS%), left ventricular ejection fraction (EF%), maximum outflow tract pressure gradients (RVOT PGmax and LVOT PGmax), left ventricular end-diastolic volume (LVEDV) and left ventricular end-systolic volume (LVESV), stroke volume (SV) and cardiac output (CO). HR, LAD, LVPWs, IVSs increased significantly in the first trimester. AoD and RVIDd were significantly higher around parturition. LVIDd, FS%, EF%, SV and CO rose both in the first and third trimester. No measurement decreased during pregnancy. The study confirms that pregnancy causes changes in the heart size and functioning. Copyright © 2018. Published by Elsevier Ltd.
Hoover, Donald B; Shepherd, Angela V; Southerland, E Marie; Armour, J Andrew; Ardell, Jeffrey L
2008-08-18
While much is known about the influence of ventricular afferent neurons on cardiovascular function in the dog, identification of the neurochemicals transmitting cardiac afferent signals to central neurons is lacking. Accordingly, we identified ventricular afferent neurons in canine dorsal root ganglia (DRG) and nodose ganglia by retrograde labeling after injecting horseradish peroxidase (HRP) into the anterior right and left ventricles. Primary antibodies from three host species were used in immunohistochemical experiments to simultaneously evaluate afferent somata for the presence of HRP and markers for two neurotransmitters. Only a small percentage (2%) of afferent somata were labeled with HRP. About half of the HRP-identified ventricular afferent neurons in T(3) DRG also stained for substance P (SP), calcitonin gene-related peptide (CGRP), or neuronal nitric oxide synthase (nNOS), either alone or with two markers colocalized. Ventricular afferent neurons and the general population of T(3) DRG neurons showed the same labeling profiles; CGRP (alone or colocalized with SP) being the most common (30-40% of ventricular afferent somata in T(3) DRG). About 30% of the ventricular afferent neurons in T(2) DRG displayed CGRP immunoreactivity and binding of the putative nociceptive marker IB(4). Ventricular afferent neurons of the nodose ganglia were distinct from those in the DRG by having smaller size and lacking immunoreactivity for SP, CGRP, and nNOS. These findings suggest that ventricular sensory information is transferred to the central nervous system by relatively small populations of vagal and spinal afferent neurons and that spinal afferents use a variety of neurotransmitters.
Sengupta, Shantanu P; Jaju, Rahul; Nugurwar, Abhijeet; Caracciolo, Giuseppe; Sengupta, Partho P
2012-01-01
The status of left ventricle in sickle cell anemia presenting in sickle crisis and follow up has been minimally studied in past. To determine the left ventricular (LV) myocardial performance in these patients, we performed the study to assess two dimensional strains imaging which allowed a rapid and an accurate analysis of global and regional LV myocardial performance in longitudinal, radial, and circumferential directions. In this prospective study, 2-dimensional echocardiography (2DE) images of the LV were obtained in 52 subjects which included 32 patients (23 ± 8yrs, 16 male) with homozygous sickle cell anemia (SCA) in sickle cell crisis and 20 healthy controls (23 ± 5 yrs, 11 male) using apical 4-chamber and parasternal short-axis at the basal, mid, and apical levels. Of these 32 patients, 2DE was performed again in 18 patients in follow up (8 months ± 5 days). Longitudinal, circumferential and radial strains (LS, CS and RS respectively) were quantified and compared in an 18-segment model using a novel speckle tracking system (2D Cardiac Performance Analysis, TomTec Imaging System, Munich, Germany). There was no significant difference in LV ejection fraction between both the groups (59.32 ± 12.6 vs. 52.3 ± 7.9; p-value > 0.05). In comparison with normal controls and follow up of sickle cell patients, peak LS was significantly attenuated in the subendocardial and subepicardial regions during sickle cell crisis (p < 0.05). However, a significant reduction in circumferential strain was evident only in subepicardial region (p < 0.001). Also patients in sickle cell crisis showed significantly higher radial strain parameters than controls (p < 0.001). Patients with SCA presenting in sickle cell crisis have reduced longitudinal shortening. LV myocardial performance remains unaltered due to relatively preserved circumferential shortening and increased radial thickening. Copyright © 2012 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Narula, Sukrit; Shameer, Khader; Salem Omar, Alaa Mabrouk; Dudley, Joel T; Sengupta, Partho P
2016-11-29
Machine-learning models may aid cardiac phenotypic recognition by using features of cardiac tissue deformation. This study investigated the diagnostic value of a machine-learning framework that incorporates speckle-tracking echocardiographic data for automated discrimination of hypertrophic cardiomyopathy (HCM) from physiological hypertrophy seen in athletes (ATH). Expert-annotated speckle-tracking echocardiographic datasets obtained from 77 ATH and 62 HCM patients were used for developing an automated system. An ensemble machine-learning model with 3 different machine-learning algorithms (support vector machines, random forests, and artificial neural networks) was developed and a majority voting method was used for conclusive predictions with further K-fold cross-validation. Feature selection using an information gain (IG) algorithm revealed that volume was the best predictor for differentiating between HCM ands. ATH (IG = 0.24) followed by mid-left ventricular segmental (IG = 0.134) and average longitudinal strain (IG = 0.131). The ensemble machine-learning model showed increased sensitivity and specificity compared with early-to-late diastolic transmitral velocity ratio (p < 0.01), average early diastolic tissue velocity (e') (p < 0.01), and strain (p = 0.04). Because ATH were younger, adjusted analysis was undertaken in younger HCM patients and compared with ATH with left ventricular wall thickness >13 mm. In this subgroup analysis, the automated model continued to show equal sensitivity, but increased specificity relative to early-to-late diastolic transmitral velocity ratio, e', and strain. Our results suggested that machine-learning algorithms can assist in the discrimination of physiological versus pathological patterns of hypertrophic remodeling. This effort represents a step toward the development of a real-time, machine-learning-based system for automated interpretation of echocardiographic images, which may help novice readers with limited experience. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Shehab, Sajad; Allida, Sabine M; Davidson, Patricia M; Newton, Phillip J; Robson, Desiree; Jansz, Paul C; Hayward, Christopher S
Right ventricular failure after left ventricular assist device (LVAD) implantation is associated with high mortality. Management remains limited to pharmacologic therapy and temporary mechanical support. Delayed right ventricular assist device (RVAD) support after LVAD implantation is associated with poorer outcomes. With the advent of miniaturized, durable, continuous flow ventricular assist device systems, chronic RVAD and biventricular assist device (BiVAD) support has been used with some success. The purpose of this study was to assess combined BiVAD and LVAD with delayed RVAD support within a four-elemental mock circulatory loop (MCL) simulating the human cardiovascular system. Our hypothesis was that delayed continuous flow RVAD (RVAD) would produce similar hemodynamic and flow parameters to those of initial BiVAD support. Using the MCL, baseline biventricular heart failure with elevated right and left filling pressures with low cardiac output was simulated. The addition of LVAD within a biventricular configuration improved cardiac output somewhat, but was associated with persistent right heart failure with elevated right-sided filling pressures. The addition of an RVAD significantly improved LVAD outputs and returned filling pressures to normal throughout the circulation. In conclusion, RVAD support successfully restored hemodynamics and flow parameters of biventricular failure supported with isolated LVAD with persistent elevated right atrial pressure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhainaut, J.F.; Devaux, J.Y.; Monsallier, J.F.
1986-07-01
Continuous positive pressure ventilation is associated with a reduction in left ventricular preload and cardiac output, but the mechanisms responsible are controversial. The decrease in left ventricular preload may result exclusively from a decreased systemic venous return due to increased pleural pressure, or from an additional effect such as decreased left ventricular compliance. To determine the mechanisms responsible, we studied the changes in cardiac output induced by continuous positive pressure ventilation in eight patients with the adult respiratory distress syndrome. We measured cardiac output by thermodilution, and biventricular ejection fraction by equilibrium gated blood pool scintigraphy. Biventricular end-diastolic volumes weremore » then calculated by dividing stroke volume by ejection fraction. As positive end-expiratory pressure increased from 0 to 20 cm H/sub 2/O, stroke volume and biventricular end-diastolic volumes fell about 25 percent, and biventricular ejection fraction remained unchanged. At 20 cm H/sub 2/O positive end-expiratory pressure, volume expansion for normalizing cardiac output restored biventricular end-diastolic volumes without markedly changing biventricular end-diastolic transmural pressures. The primary cause of the reduction in left ventricular preload with continuous positive pressure ventilation appears to be a fall in venous return and hence in right ventricular stroke volume, without evidence of change in left ventricular diastolic compliance.« less
Development of an implantable ventricular assist system.
Macris, M P; Parnis, S M; Frazier, O H; Fuqua, J M; Jarvik, R K
1997-02-01
This study describes the present state of progress in the development of the Jarvik 2000 ventricular assist system. Designed for implantation in the human thorax, the system consists of a small (25 cm3, 90 g) intraventricular axial-flow blood pump that transmits power and data via internal electronics and a transcutaneous energy transfer system. The pump is powered by portable internal and external polymer lithium ion batteries. The only moving part, the pump rotor, contains a permanent magnet of a brushless direct-current motor that mounts an axial-flow impeller and partial magnetic thrust support, with blood-immersed radial and thrust bearings. The motor uses a redundant coil and electric lead design, which permits continued operation in case of wire breakage. Seven calves have been supported for an average of 107 days (range, 40 to 162 days) with prototypes of the Jarvik 2000 ventricular assist system. No physiologic complications have occurred. When its user is at rest, the pump produces flows of 5 to 6 L/min with a decreased arterial pulse contour. Renal and hepatic functions have remained normal throughout the duration of all studies. Mean plasma free hemoglobin levels ranged from 4.3 to 11.4 mg/dL (mean, 6.3 mg/dL) for each study. Pathologic analyses of the heart and kidneys revealed no damage related to the device. These studies indicate that the Jarvik 2000 ventricular assist system is feasible in animals and holds promise for long-term support of patients.
Pu, Jun; Ding, Song; Ge, Heng; Han, Yaling; Guo, Jinchen; Lin, Rong; Su, Xi; Zhang, Heng; Chen, Lianglong; He, Ben
2017-10-17
Timely primary percutaneous coronary intervention (PPCI) cannot be offered to all patients with ST-segment-elevation myocardial infarction (STEMI). Pharmaco-invasive (PhI) strategy has been proposed as a valuable alternative for eligible patients with STEMI. We conducted a randomized study to compare the efficacy and safety of a PhI strategy with half-dose fibrinolytic regimen versus PPCI in patients with STEMI. The EARLY-MYO trial (Early Routine Catheterization After Alteplase Fibrinolysis Versus Primary PCI in Acute ST-Segment-Elevation Myocardial Infarction) was an investigator-initiated, prospective, multicenter, randomized, noninferiority trial comparing a PhI strategy with half-dose alteplase versus PPCI in patients with STEMI 18 to 75 years of age presenting ≤6 hours after symptom onset but with an expected PCI-related delay. The primary end point of the study was complete epicardial and myocardial reperfusion after PCI, defined as thrombolysis in myocardial infarction flow grade 3, thrombolysis in myocardial infarction myocardial perfusion grade 3, and ST-segment resolution ≥70%. We also measured infarct size and left ventricular ejection fraction with cardiac magnetic resonance and recorded 30-day clinical and safety outcomes. A total of 344 patients from 7 centers were randomized to PhI (n=171) or PPCI (n=173). PhI was noninferior (and even superior) to PPCI for the primary end point (34.2% versus 22.8%, P noninferiority <0.05, P superiority =0.022), with no significant differences in the frequency of the individual components of the combined end point: thrombolysis in myocardial infarction flow 3 (91.3% versus 89.2%, P =0.580), thrombolysis in myocardial infarction myocardial perfusion grade 3 (65.8% versus 62.9%, P =0.730), and ST-segment resolution ≥70% (50.9% versus 45.5%, P =0.377). Infarct size (23.3%±11.3% versus 25.8%±13.7%, P =0.101) and left ventricular ejection fraction (52.2%±11.0% versus 51.4%±12.0%, P =0.562) were similar in both groups. No significant differences occurred in 30-day rates of total death (0.6% versus 1.2%, P =1.0), reinfarction (0.6% versus 0.6%, P =1.0), heart failure (13.5% versus 16.2%, P =0.545), major bleeding events (0.6% versus 0%, P =0.497), or intracranial hemorrhage (0% versus 0%), but minor bleeding (26.9% versus 11.0%, P <0.001) was observed more often in the PhI group. For patients with STEMI presenting ≤6 hours after symptom onset and with an expected PCI-related delay, a PhI strategy with half-dose alteplase and timely PCI offers more complete epicardial and myocardial reperfusion when compared with PPCI. Adequately powered trials with this reperfusion strategy to assess clinical and safety outcomes are warranted. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01930682. © 2017 American Heart Association, Inc.
NASA Technical Reports Server (NTRS)
Dorosz, Jennifer L.; Bolson, Edward L.; Waiss, Mary S.; Sheehan, Florence H.
2003-01-01
Three-dimensional guidance programs have been shown to increase the reproducibility of 2-dimensional (2D) left ventricular volume calculations, but these systems have not been tested in 2D measurements of the right ventricle. Using magnetic fields to identify the probe location, we developed a new 3-dimensional guidance system that displays the line of intersection, the plane of intersection, and the numeric angle of intersection between the current image plane and previously saved scout views. When used by both an experienced and an inexperienced sonographer, this guidance system increases the accuracy of the 2D right ventricular volume measurements using a monoplane pyramidal model. Furthermore, a reconstruction of the right ventricle, with a computed volume similar to the calculated 2D volume, can be displayed quickly by tracing a few anatomic structures on 2D scans.
Cardiac structure and function in Cushing's syndrome: a cardiac magnetic resonance imaging study.
Kamenický, Peter; Redheuil, Alban; Roux, Charles; Salenave, Sylvie; Kachenoura, Nadjia; Raissouni, Zainab; Macron, Laurent; Guignat, Laurence; Jublanc, Christel; Azarine, Arshid; Brailly, Sylvie; Young, Jacques; Mousseaux, Elie; Chanson, Philippe
2014-11-01
Patients with Cushing's syndrome have left ventricular (LV) hypertrophy and dysfunction on echocardiography, but echo-based measurements may have limited accuracy in obese patients. No data are available on right ventricular (RV) and left atrial (LA) size and function in these patients. The objective of the study was to evaluate LV, RV, and LA structure and function in patients with Cushing's syndrome by means of cardiac magnetic resonance, currently the reference modality in assessment of cardiac geometry and function. Eighteen patients with active Cushing's syndrome and 18 volunteers matched for age, sex, and body mass index were studied by cardiac magnetic resonance. The imaging was repeated in the patients 6 months (range 2-12 mo) after the treatment of hypercortisolism. Compared with controls, patients with Cushing's syndrome had lower LV, RV, and LA ejection fractions (P < .001 for all) and increased end-diastolic LV segmental thickness (P < .001). Treatment of hypercortisolism was associated with an improvement in ventricular and atrial systolic performance, as reflected by a 15% increase in the LV ejection fraction (P = .029), a 45% increase in the LA ejection fraction (P < .001), and an 11% increase in the RV ejection fraction (P = NS). After treatment, the LV mass index and end-diastolic LV mass to volume ratio decreased by 17% (P < .001) and 10% (P = .002), respectively. None of the patients had late gadolinium myocardial enhancement. Cushing's syndrome is associated with subclinical biventricular and LA systolic dysfunctions that are reversible after treatment. Despite skeletal muscle atrophy, Cushing's syndrome patients have an increased LV mass, reversible upon correction of hypercortisolism.
[A case of lupus myocarditis and nephritis with transient foramen jugular syndrome].
Kohro-Kawata, J; Nakamura, H; Yamamoto, T; Fukuta, S; Matsuzaki, M
1997-10-01
A 46-year-old man was admitted to our clinic because of acute heart failure. Six years before admission he was pointed out cardiomegary and hematuria. One year later, he was diagnosed as having jugular foramen syndrome. On admission, he had a fever and dyspnea. Pansystolic blowing murmur was audible at the apex. The chest ratio on his chest X-ray was 52.5%. An electrocardiogram showed left ventricular hypertrophy. An echocardiogram showed marked dilatation and severe dysfunction of left ventricle. Radionuclide scanning with technetium 99 m pyrophosphate identified inflammatory change in the apex. Myocardial biopsy showed fibrotic degeneration and IgG deposits in myocardium. Blood examination showed anemia, lymphopenia. positive anti-nuclear antibody (1000 times, shaggy pattern), positive anti ds-DNA antibody and hypocomplementemia. Furthermore, proteinuria was pointed out. Renal biopsy showed focal segmental glomerulonephritis with active necrotizing lesion (type III nephritis). Lupus myocarditis and nephritis was diagnosed. After prednisolone (80 mg/day) was administered. left ventricular function and hypocomplementemia improved. The ACE inhibitor was also used for proteinuria. In spite of a little amount of blood transfusion, he showed hepatic hemosiderosis. We suspect that the cause of hemosiderosis was related chronic inflammation of active lupus. It was treated with Erythropoietin.
Elikowski, Waldemar; Małek-Elikowska, Małgorzata; Słomczyński, Marek; Horbacka, Karolina; Bartkowski, Jarosław; Kalawski, Bartosz
2017-10-23
Bupivacaine is a long-acting local anesthetic (LA) used for cutaneous infiltration, peripheral nerve blocks, epidural and spinal anesthesia. However, its application may result in cardiovascular complications such as: hypotension, bradycardia, cardiac arrest and toxic myocardial injury. The authors describe a 53-year-old male with a history of cigarette smoking, admitted for an elective inguinal hernia surgery. Before surgery, the patient received subarachnoid injection of bupivacaine (20 mg). After the operation, he developed transient hypotension. Blood pressure returned to normal after gelofusine infusion; no sympathomimetics were administered. The male denied chest pain; however, ECG showed ST segment elevation coexisting with left ventricular anterolateral hypokinesia and decreased longitudinal strain in echocardiography. A significant increase in troponin I level was suggestive rather of myocardial infarction than of takotsubo cardiomyopathy. Urgent coronary angiography revealed left anterior descending artery spasm, which remitted after intracoronary nitroglycerin injection. Normalization of ECG and echocardiography was observed within a few days. The authors indicate that the presented atypical adverse effect of bupivacaine manifested itself with delay and that coronary spasm proceeded without angina. A close observation of the patient after anesthetic procedure with LA should be extended over the postoperative period.
Ju, Xiang-Chun; Hou, Qiong-Qiong; Sheng, Ai-Li; Wu, Kong-Yan; Zhou, Yang; Jin, Ying; Wen, Tieqiao; Yang, Zhengang; Wang, Xiaoqun; Luo, Zhen-Ge
2016-01-01
Cortical expansion and folding are often linked to the evolution of higher intelligence, but molecular and cellular mechanisms underlying cortical folding remain poorly understood. The hominoid-specific gene TBC1D3 undergoes segmental duplications during hominoid evolution, but its role in brain development has not been explored. Here, we found that expression of TBC1D3 in ventricular cortical progenitors of mice via in utero electroporation caused delamination of ventricular radial glia cells (vRGs) and promoted generation of self-renewing basal progenitors with typical morphology of outer radial glia (oRG), which are most abundant in primates. Furthermore, down-regulation of TBC1D3 in cultured human brain slices decreased generation of oRGs. Interestingly, localized oRG proliferation resulting from either in utero electroporation or transgenic expression of TBC1D3, was often found to underlie cortical regions exhibiting folding. Thus, we have identified a hominoid gene that is required for oRG generation in regulating the cortical expansion and folding. DOI: http://dx.doi.org/10.7554/eLife.18197.001 PMID:27504805
Huelnhagen, Till; Hezel, Fabian; Serradas Duarte, Teresa; Pohlmann, Andreas; Oezerdem, Celal; Flemming, Bert; Seeliger, Erdmann; Prothmann, Marcel; Schulz-Menger, Jeanette; Niendorf, Thoralf
2017-06-01
Myocardial effective relaxation time T2* is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence T2*. To this end, this study investigates the relationship between T2* and cardiac macromorphology given by left ventricular (LV) wall thickness and left ventricular radius, and provides interpretation of the results in the physiological context. High spatio-temporally resolved myocardial CINE T2* mapping was performed in 10 healthy volunteers using a 7.0 Tesla (T) full-body MRI system. Ventricular septal wall thickness, left ventricular inner radius, and T2* were analyzed. Macroscopic magnetic field changes were elucidated using cardiac phase-resolved magnetic field maps. Ventricular septal T2* changes periodically over the cardiac cycle, increasing in systole and decreasing in diastole. Ventricular septal wall thickness and T2* showed a significant positive correlation, whereas the inner LV radius and T2* were negatively correlated. The effect of macroscopic magnetic field gradients on T2* can be considered minor in the ventricular septum. Our findings suggest that myocardial T2* is related to tissue blood volume fraction. Temporally resolved T2* mapping could be beneficial for myocardial tissue characterization and for understanding cardiac (patho)physiology in vivo. Magn Reson Med 77:2381-2389, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
NASA Astrophysics Data System (ADS)
Mazonakis, Michalis; Grinias, Elias; Pagonidis, Konstantin; Tziritas, George; Damilakis, John
2010-02-01
The purpose of this study was to develop and evaluate a semiautomatic method for left ventricular (LV) segmentation on cine MR images and subsequent estimation of cardiac parameters. The study group comprised cardiac MR examinations of 18 consecutive patients with known or suspected coronary artery disease. The new method allowed the automatic detection of the LV endocardial and epicardial boundaries on each short-axis cine MR image using a Bayesian flooding segmentation algorithm and weighted least-squares B-splines minimization. Manual editing of the automatic contours could be performed for unsatisfactory segmentation results. The end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF) and LV mass estimated by the new method were compared with the reference values obtained by manually tracing the LV cavity borders. The reproducibility of the new method was determined using data from two independent observers. The mean number of endocardial and epicardial outlines not requiring any manual adjustment was more than 80% and 76% of the total contour number per study, respectively. The mean segmentation time including the required manual corrections was 2.3 ± 0.7 min per patient. LV volumes estimated by the semiautomatic method were significantly lower than those by manual tracing (P < 0.05), whereas no difference was found for EF and LV mass (P > 0.05). LV indices estimated by the two methods were well correlated (r >= 0.80). The mean difference between manual and semiautomatic method for estimating EDV, ESV, EF and LV mass was 6.1 ± 7.2 ml, 3.0 ± 5.2 ml, -0.6 ± 4.3% and -6.2 ± 12.2 g, respectively. The intraobserver and interobserver variability associated with the semiautomatic determination of LV indices was 0.5-1.2% and 0.8-3.9%, respectively. The estimation of LV parameters with the new semiautomatic segmentation method is technically feasible, highly reproducible and time effective.
Tsiflikas, Ilias; Drosch, Tanja; Brodoefel, Harald; Thomas, Christoph; Reimann, Anja; Till, Alexander; Nittka, Daniel; Kopp, Andreas F; Schroeder, Stephen; Heuschmid, Martin; Burgstahler, Christof
2010-08-06
Cardiac multi-detector computed tomography (MDCT) permits accurate visualization of high-grade coronary artery stenosis. However, in patients with heart rate irregularities, MDCT was found to have limitations. Thus, the aim of the present study was to evaluate the diagnostic accuracy of a new dual-source computed tomography (DSCT) scanner generation with 83 ms temporal resolution in patients without stable sinus rhythm. 44 patients (31 men, mean age 67.5+/-9.2 years) without stable sinus rhythm and scheduled for invasive coronary angiography (ICA) because of suspected (n=17) or known coronary artery disease (CAD, n=27) were included in this study. All patients were examined with DSCT (Somatom Definition, Siemens). Besides assessment of total calcium score, all coronary segments were analyzed with regard to the presence of significant coronary artery lesions (>50%). The findings were compared to ICA in a blinded fashion. During CT examination, heart rhythm was as follows: 25 patients (57%) atrial fibrillation, 7 patients (16%) ventricular extrasystoles (two of them with atrial fibrillation), 4 patients (9%) supraventricular extrasystoles, 10 patients (23%) sinus arrhythmia (heart rate variability>10 bpm). Mean heart rate was 69+/-14 bpm, median 65 bpm. Mean Agatston score equivalent (ASE) was 762, ranging from 0 to 4949.7 ASE. Prevalence of CAD was 68% (30/44). 155 segments (27%) showed "step-ladder" artifacts and 28 segments (5%) could not be visualized by DSCT. Only 70 segments (12%) were completely imaged without any artifacts. Based on a coronary segment model, sensitivity was 73%, specificity 91%, positive predictive value 63%, and negative predictive value 94% for the detection of significant lesions (>or=50% diameter stenosis). Overall accuracy was 88%. In patients with heart rate irregularities, including patients with atrial fibrillation and a high prevalence of coronary artery disease, the diagnostic yield of dual-source computed tomography is still hampered due to a high number of segments with "step-ladder" artifacts. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.
Brugada syndrome and ischemia-induced ST-segment elevation. Similarities and differences#
Di Diego, José M.; Fish, Jeffrey M.; Antzelevitch, Charles
2006-01-01
Introduction ST-Segment elevation is a common electrocardiogram (ECG) manifestation of acute transmural myocardial ischemia in leads facing the injury. Acute myocardial ischemia involving the right-ventricular (RV) outflow tract is known to induce a Brugada-like ECG. In this paper, we examined the electrophysiological bases for the similarities between the ECG characteristics of the Brugada syndrome model induced by terfenadine (5 μmol/L) and the ECG manifestations of the acute transmural no-flow ischemia model. Methods For both experimental simulations, we used isolated arterially perfused canine RV wedge preparations to record transmembrane action potentials (AP) from endocardium and epicardium together with a transmural pseudo-ECG (ECG); basic cycle length = 400 to 2000 ms. Results In the presence of a prominent Ito-mediated AP notch, no-flow ischemia causes true ST-segment elevation because of selective depression and loss of the AP dome at some epicardial sites. In the absence of a prominent AP notch, ischemia ultimately produces an apparent ST-segment elevation, which is secondary to a prolongation of the R wave caused by marked transmural conduction delays. Similarly, in the Brugada syndrome model generated in preparations displaying a large epicardial Ito, ST-segment elevation was due to loss of the epicardial AP dome at some sites but not at others. Transmural conduction delay giving the appearance of ST-segment elevation is also observed in the Brugada model in preparations exhibiting smaller AP notch. In both models, propagation of the dome from the site at which it is maintained to a site at which it is lost may result in closely coupled phase 2 reentrant extrasystoles. Conclusion Our results suggest that Ito can modulate the electrocardiographic manifestation of acute ischemia as well as that of the Brugada syndrome, and that both clinical entities are the result of a similar electrophysiological substrate. PMID:16226068
CT-1-CP-induced ventricular electrical remodeling in mice.
Chen, Shu-fen; Wei, Tao-zhi; Rao, Li-ya; Xu, Ming-guang; Dong, Zhan-ling
2015-02-01
The chronic effects of carboxyl-terminal polypeptide of Cardiotrophin-1 (CT-1-CP) on ventricular electrical remodeling were investigated. CT-1-CP, which contains 16 amino acids in sequence of the C-terminal of Cardiotrophin-1, was selected and synthesized, and then administered to Kunming mice (aged 5 weeks) by intraperitoneal injection (500 ng·g⁻¹·day⁻¹) (4 groups, n=10 and female: male=1:1 in each group) for 1, 2, 3 and 4 weeks, respectively. The control group (n=10, female: male=1:1) was injected by physiological saline for 4 weeks. The epicardial monophasic action potential (MAP) was recorded by using a contact-type MAP electrode placed vertically on the left ventricular (LV) epicardium surface, and the electrocardiogram (ECG) signal in lead II was monitored synchronously. ECG intervals (RR, PR, QRS and QT) and the amplitude of MAP (Am), the maximum upstroke velocity (Vmax), as well as action potential durations (APDs) at different repolarization levels (APD30, APD50, APD70, and APD90) of MAP were determined and analyzed in detail. There were no significant differences in RR and P intervals between CT-1-CP-treated groups and control group, but the PR segment and the QRS complex were greater in the former than in the latter (F=2.681 and 5.462 respectively, P<0.05). Though QT interval and the corrected QT interval (QTc) were shorter in CT-1-CP-treated groups than in control group, the QT dispersion (QTd) of them was greater in the latter than in the former (F=3.090, P<0.05) and increased with the time. The ECG monitoring synchronously with the MAP showed that the compression of MAP electrode on the left ventricular epicardium induced performance similar to myocardium ischemia. As compared with those before chest-opening, the PR segment and QT intervals remained basically unchanged in control group, but prolonged significantly in all CT-1-CP-treated groups and the prolongation of QT intervals increased gradually along with the time of exposure to CT-1-CP. The QRS complex had no significant change in control group, one-week and three-week CT-1-CP-treated groups, but prolonged significantly in two-week and four-week CT-1-CP-treated groups. Interestingly, the QTd after chest-opening was significantly greater than that before chest-opening in control group (t=5.242, P<0.01), but decreased along with the time in CT-1-CP-treated groups. The mean MAP amplitude, Vmax and APD were greater in CT-1-CP-treated groups than those in control group, and became more obvious along with the time. The APD in four CT-1-CP-treat groups was prolonged mainly in middle to final repolarization phase. The difference among these groups became significant in middle phase (APD50) (F=6.076, P<0.01) and increased furthermore in late and final phases (APD70: F=10.054; APD90: F=18.691, P<0.01) along with the time of injection of CT-1-CP. The chronic action of CT-1-CP might induce the adapting alteration in cardiac conductivity and ventricular repolarization. The amplitude and the Vmax of the anterior LV epicardial MAP increased obviously, and the APD prolonged mainly in late and final phase of repolarization.
Kral Kollars, Catharine A; Gelehrter, Sarah; Bove, Edward L; Ensing, Gregory
2010-03-01
Congenitally corrected transposition of the great arteries (CCTGA) is associated with tricuspid regurgitation (TR), which has been postulated to arise from the effect of ventricular septal position on the attachments of the tricuspid valve. This study was performed to determine the effect of left ventricular (LV) pressure on right ventricular (RV) and LV geometry and the degree of TR. Serial echocardiograms were reviewed from, 30 patients with CCTGA who underwent pulmonary artery banding to train the morphologic left ventricle (n = 14) or left ventricle-to-pulmonary artery conduit placement and ventricular septal defect closure in conjunction with physiologic repair (n = 16). The degree of TR, the LV/RV pressure ratio, RV and LV sphericity indexes, and tricuspid valve tethering distance and coaptation length were analyzed. After pulmonary artery banding, an increase in LV systolic pressure to > or =2/3 systemic resulted in a decrease in TR from severe to moderate (p = 0.02). The percentage of patients with severe TR decreased from 64% to 18% (p = 0.06). The RV sphericity index decreased (p = 0.05), and the LV sphericity index increased (p = 0.02). After left ventricle-to-pulmonary artery conduit placement, a decrease in LV pressure to < or =1/2 systemic resulted in an increase in TR from none to mild (p = 0.003). In conclusion, these data indicate that LV pressure in patients with CCTGA affects the degree of TR and that septal shift caused by changes in LV and RV pressure is an important mechanism. Copyright 2010. Published by Elsevier Inc.
How best to assess right ventricular function by echocardiography*
DiLorenzo, Michael P.; Bhatt, Shivani M.; Mercer-Rosa, Laura
2016-01-01
Right ventricular function is a crucial determinant of long-term outcomes of children with heart disease. Quantification of right ventricular systolic and diastolic performance by echocardiography is of paramount importance, given the prevalence of children with heart disease, particularly those with involvement of the right heart, such as single or systemic right ventricles, tetralogy of Fallot, and pulmonary arterial hypertension. Identification of poor right ventricular performance can provide an opportunity to intervene. In this review, we will go through the different systolic and diastolic indices, as well as their application in practice. Quantification of right ventricular function is possible and should be routinely performed using a combination of different measures, taking into account each disease state. Quantification is extremely useful for individual patient follow-up. Laboratories should continue to strive to optimise reproducibility through quality improvement and quality assurance efforts in addition to investing in technology and training for new, promising techniques, such as three-dimensional echocardiography. PMID:26675593
Left ventricular outflow obstruction and necrotizing enterocolitis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, H.A.; Haney, P.J.
1984-02-01
Two neonates had unusually rapid development of necrotizing enterocolitis within 24 hours of birth. Both patients had decreased systemic perfusion secondary to aortic atresia. Onset of either clinical or radiographic manifestations of necrotizing enterocolitis in the first day of life should alert one to the possible presence of severe left ventricular outflow obstruction.
Testuz, Ariane; Roffi, Marco; Bonvini, Robert Francis
2013-03-01
This case aims to describe the hemodynamic effects of intra-aortic balloon pump (IABP) in patients with ventricular septal defect (VSD) complicating myocardial infarction (MI). A 79-year-old man with no previous cardiovascular history presented to the emergency department with subacute inferior myocardial infarction associated with mild signs of systemic hypoperfusion. A transthoracic echocardiography revealed a large akinesia of the left ventricular inferior wall with preserved global left ventricular ejection fraction, as well as a large VSD in the midinferior portion of the interventricular septum. Coronary angiography showed an occlusion of the mid portion of a dominant circumflex coronary artery. The invasive hemodynamic evaluation showed a sizable left-to-right shunt (Q(p)/Q(s) = 3.1). Activation of the IABP led to an immediate reduction of the shunt (Q(p)/Q(s) = 2.4 = 22% reduction), an increase in systemic cardiac output (from 2.1 L/min to 2.4 L/min = +12%) and a decrease in the systemic vascular resistances (from 2240 to 1920 dyne-sec/cm(5) = 15% reduction). In patients with post-MI VSD, placement of IABP leads to an immediate reduction in left-to-right shunt and as a consequence to an increase in systemic cardiac output, which may allow hemodynamic stabilization of the patient prior to surgical VSD closure. Copyright © 2012 Wiley Periodicals, Inc.
Orthostatic effects on echocardiographic measures of ventricular function.
Rowland, Thomas; Unnithan, Viswanath; Barker, Piers; Guerra, Miriam; Roche, Denise; Lindley, Martin
2012-05-01
Orthostatic-induced alterations in Doppler echocardiographic measures of ventricular function have not been well-defined. Identifying such changes may provide useful insights regarding the responses of these measures to variations in ventricular loading conditions. Standard assessment of mitral inflow velocity and tissue Doppler imaging (TDI) of left ventricular longitudinal myocardial velocities was performed on 14 young males (mean age 17.9 ± 0.7 years) in the supine position and then 5 minutes after assuming a sitting position with legs dependent. Upon sitting, average values of stroke volume and cardiac output fell by 28% and 18%, respectively, while heart rate increased from 64 ± 10 to 73 ± 12 beats/min (+14%) and calculated systemic vascular resistance rose from 12.9 ± 2.2 to 16.4 ± 3.1 units (+27%). Mitral E peak velocity declined from 87 ± 16 to 64 ± 16 cm/sec, and average TDI-E' and TDI-S both decreased (by -44% and -20%, respectively). When adjusted for orthostatic decreases in left ventricular end-diastolic volume, the mean decrease in TDI-E' was reduced to -29 (P < 0.01), but no significant decline was observed in adjusted TDI-S. Average E/E' rose with sitting by 40% (P = 0.02). These findings suggest that (a) decreases in TDI measures when assuming the upright position reflect the reduction of left ventricular size; (b) orthostatic fall in TDI-E' is also related to smaller ventricular size but, in addition, to a nonspecified reduction in ventricular relaxation; and (c) values of E/E' do not reflect alterations in ventricular preload, which occur during an orthostatic challenge. © 2012, Wiley Periodicals, Inc.
Muscular anatomy of the human ventricular folds.
Moon, Jerald; Alipour, Fariborz
2013-09-01
Our purpose in this study was to better understand the muscular anatomy of the ventricular folds in order to help improve biomechanical modeling of phonation and to better understand the role of these muscles during phonatory and nonphonatory tasks. Four human larynges were decalcified, sectioned coronally from posterior to anterior by a CryoJane tape transfer system, and stained with Masson's trichrome. The total and relative areas of muscles observed in each section were calculated and used for characterizing the muscle distribution within the ventricular folds. The ventricular folds contained anteriorly coursing thyroarytenoid and ventricularis muscle fibers that were in the lower half of the ventricular fold posteriorly, and some ventricularis muscle was evident in the upper and lateral portions of the fold more anteriorly. Very little muscle tissue was observed in the medial half of the fold, and the anterior half of the ventricular fold was largely devoid of any muscle tissue. All 4 larynges contained muscle bundles that coursed superiorly and medially through the upper half of the fold, toward the lateral margin of the epiglottis. Although variability of expression was evident, a well-defined thyroarytenoid muscle was readily apparent lateral to the arytenoid cartilage in all specimens.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Follansbee, W.P.; Curtiss, E.I.; Medsger, T.A. Jr.
1984-09-01
Myocardial function and perfusion were evaluated in 22 patients with progressive systemic sclerosis with the CREST syndrome using exercise and radionuclide techniques, pulmonary function testing, and chest roentgenography. The results were compared with a similar study of 26 patients with progressive systemic sclerosis with diffuse scleroderma. The prevalence of thallium perfusion abnormalities was similar in the groups with CREST syndrome and diffuse scleroderma, (64 percent versus 77 percent), but the defects were significantly smaller in the CREST syndrome (p less than 0.01). Reperfusion thallium defects in the absence of extramural coronary artery disease were seen in 38 percent of patientsmore » with diffuse scleroderma. This finding was not seen in any of the patients with the CREST syndrome. In diffuse scleroderma, abnormalities of both right and left ventricular function were related to larger thallium perfusion defects. In the CREST syndrome, abnormalities of left ventricular function were minor, were seen only during exercise, and were unrelated to thallium perfusion defects. Abnormal resting right ventricular function was seen in 36 percent of the patients with the CREST syndrome and was associated with an isolated decrease in diffusing capacity of carbon monoxide. It is concluded that the cardiac manifestations of the CREST syndrome are distinct from those found in diffuse scleroderma. Unlike diffuse scleroderma, abnormalities of left ventricular function in the CREST syndrome are minor and are unrelated to abnormalities of coronary perfusion. Right ventricular dysfunction in the CREST syndrome appears to be primarily related to pulmonary vascular disease.« less
Arakawa, Kentaro; Himeno, Hideo; Kirigaya, Jin; Otomo, Fumie; Matsushita, Kensuke; Nakahashi, Hidefumi; Shimizu, Satoru; Nitta, Manabu; Takamizawa, Tetsu; Yano, Hideto; Endo, Mitsuaki; Kanna, Masahiko; Kimura, Kazuo; Umemura, Satoshi
2016-02-01
In animal models of acute myocardial infarction (AMI), B-type natriuretic peptide (BNP) administered before and during coronary occlusion limits infarct size. However, the relation between plasma BNP levels and ischemia/reperfusion injury remains unclear. 302 patients with ST-segment elevation AMI (STEMI) received emergency percutaneous coronary intervention within six hours from the onset. The patients were divided into two groups according to the plasma BNP level before angiography: group L (n=151), BNP ≤ 32.2 pg/ml; group H (n=151), BNP >32.2 pg/ml. The Selvester QRS-scoring system was used to estimate infarct size. The rate of ischemia/reperfusion injury immediately after reperfusion, defined as reperfusion ventricular arrhythmias (26% vs. 11%, p=0.001) and ST-segment re-elevation (44% vs. 22%, p=0.008), was higher in group L than in group H. Group L had a greater increase in the QRS score during percutaneous coronary intervention (3.55 ± 0.17 vs. 2.09 ± 0.17, p<0.001) and a higher QRS score 1 h after percutaneous coronary intervention (5.77 ± 0.28 vs. 4.51 ± 0.28, p=0.002). On multivariate analysis, plasma BNP levels in the lower 50th percentile were an independent predictor of reperfusion injury (odds ratio, 2.620; p<0.001). The odds ratios of reperfusion injury according to decreasing quartiles of BNP level, as compared with the highest quartile, were 1.536, 3.692 and 4.964, respectively (p trend=0.002). Plasma BNP level before percutaneous coronary intervention may be a predictor of ischemia/reperfusion injury and the resultant extent of myocardial damage. Our findings suggest that high plasma BNP levels might have a clinically important protective effect on ischemic myocardium in patients with STEMI who receive percutaneous coronary intervention. © The European Society of Cardiology 2015.
Bruni, J E; Reddy, K
1987-01-01
Ependymal cells of the rat central canal were examined with a view to identifying features that distinguish them regionally and from their counterparts elsewhere in the ventricular system. The results revealed that the lining consisted for the most part of a pseudostratified layer of uniformly organised cuboidal to columnar ependymal cells present in largest numbers in lumbar and sacral segments and in the conus. Two cell variants were identified on the basis of the presence or absence of a radially directed cytoplasmic process originating from the base of the cell. The tanycytic form of ependymal cell was encountered along the entire length of the central canal but with increased frequency in caudalmost segments. Ependymal cells were largely similar in ultrastructural appearance along the length of the cord. Although they were also similar in appearance and orientation to their counterparts in the ventricles they did exhibit some unique features. The most notable were the prominent junctional complexes and associated filaments present along the lateral border of the cells near their apex and the abundance of intermediate filaments in tanycytes. The central canal of the filum differed most markedly from other segments of the cord and resembled in structure the primitive ependymal tube of the caudal cord in lower vertebrates. Ependymal cells of the cord were not sufficiently dissimilar morphologically from their counterparts in the ventricles to account for differences in proliferative capacity in response to localised injury. A factor that merits further study is the difference in numbers of tanycyte ependymal cells in the two locations for they may be the reactive elements that proliferate in response to injury. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 Fig. 14 Fig. 15 PMID:3654376
Bogun, Frank; Taj, Majid; Ting, Michael; Kim, Hyungjin Myra; Reich, Stephen; Good, Eric; Jongnarangsin, Krit; Chugh, Aman; Pelosi, Frank; Oral, Hakan; Morady, Fred
2008-03-01
Pace mapping has been used to identify the site of origin of focal ventricular arrhythmias. The spatial resolution of pace mapping has not been adequately quantified using currently available three-dimensional mapping systems. The purpose of this study was to determine the spatial resolution of pace mapping in patients with idiopathic ventricular tachycardia or premature ventricular contractions originating in the right ventricular outflow tract. In 16 patients with idiopathic ventricular tachycardia/ectopy from the right ventricular outflow tract, comparisons and classifications of pace maps were performed by two observers (good pace map: match >10/12 leads; inadequate pace map: match < or =10/12 leads) and a customized MATLAB 6.0 program (assessing correlation coefficient and normalized root mean square of the difference (nRMSd) between test and template signals). With an electroanatomic mapping system, the correlation coefficient of each pace map was correlated with the distance between the pacing site and the effective ablation site. The endocardial area within the 10-ms activation isochrone was measured. The ablation procedure was effective in all patients. Sites with good pace maps had a higher correlation coefficient and lower nRMSd than sites with inadequate pace maps (correlation coefficient: 0.96 +/- 0.03 vs 0.76 +/- 0.18, P <.0001; nRMSd: 0.41 +/- 0.16 vs 0.89 +/- 0.39, P <.0001). Using receiver operating characteristic curves, appropriate cutoff values were >0.94 for correlation coefficient (sensitivity 81%, specificity 89%) and < or =0.54 for nRMSd (sensitivity 76%, specificity 80%). Good pace maps were located a mean of 7.3 +/- 5.0 mm from the effective ablation site and had a mean activation time of -24 +/- 7 ms. However, in 3 (18%) of 16 patients, the best pace map was inadequate at the effective ablation site, with an endocardial activation time at these sites of -25 +/- 12 ms. Pace maps with correlation coefficient > or =0.94 were confined to an area of 1.8 +/- 0.6 cm2. The 10-ms isochrone measured 1.2 +/- 0.7 cm2. The spatial resolution of a good pace map for targeting ventricular tachycardia/ectopy is 1.8 cm2 in the right ventricular outflow tract and therefore is inferior to the spatial resolution of activation mapping as assessed by isochronal activation. In approximately 20% of patients, pace mapping is unreliable in identifying the site of origin, possibly due a deeper site of origin and preferential conduction via fibers connecting the focus to the endocardial surface.
A computational fluid dynamics simulation framework for ventricular catheter design optimization.
Weisenberg, Sofy H; TerMaath, Stephanie C; Barbier, Charlotte N; Hill, Judith C; Killeffer, James A
2017-11-10
OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter's small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter's fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter's design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter's inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using the standard catheter hole configuration as a baseline. While the standard ventricular catheter design featuring uniform inlet hole diameters and hole spacing has a standard deviation of 14.27% for the inlet flow rates, the optimized design has a standard deviation of 0.30%. CONCLUSIONS This customizable framework, paired with high-performance computing, provides a rapid method of design testing to solve complex flow problems. While a relatively simplified ventricular catheter model was used to demonstrate the framework, the computational approach is applicable to any baseline catheter model, and it is easily adapted to optimize catheters for the unique needs of different patients as well as for other fluid-based medical devices.
Tuominen, Heikki; Haarala, Atte; Tikkakoski, Antti; Kähönen, Mika; Nikus, Kjell; Sipilä, Kalle
2018-05-02
In up to 65% of cardiac sarcoidosis patients, the disease is confined to the heart. Diagnosing isolated cardiac sarcoidosis is challenging due to the low sensitivity of endomyocardial biopsy. If cardiac sarcoidosis is part of biopsy-confirmed systemic sarcoidosis, the diagnosis can be based on cardiac imaging studies. We compared the imaging features of patients with isolated cardiac FDG uptake on positron emission tomography with those who had findings indicative of systemic sarcoidosis. 137 consecutive cardiac FDG-PET/CT studies performed on subjects suspected of having cardiac sarcoidosis were retrospectively analyzed. 33 patients had pathological left ventricular FDG uptake, and 12 of these also had pathological right ventricular uptake. 16/33 patients with pathological cardiac uptake had pathological extracardiac uptake. 10/12 patients with both LV- and RV-uptake patterns had extracardiac uptake compared to 6/21 of those with pathological LV uptake without RV uptake. SUVmax values in the myocardium were higher among patients with abnormal extracardiac uptake. The presence of extracardiac uptake was the only imaging-related factor that could predict a biopsy indicative of sarcoidosis. Right ventricular involvement seems to be more common in patients who also have findings suggestive of suspected systemic sarcoidosis, compared with patients with PET findings indicative of isolated cardiac disease.
Hydrocephalus secondary to obstruction of the lateral apertures in two dogs.
Kent, M; Glass, E N; Haley, A C; Shaikh, L S; Sequel, M; Blas-Machado, U; Bishop, T M; Holmes, S P; Platt, S R
2016-11-01
Traditionally, hydrocephalus is divided into communicating or non-communicating (obstructive) based on the identification of a blockage of cerebrospinal fluid (CSF) flow through the ventricular system. Hydrocephalus ex vacuo refers to ventricular enlargement as a consequence of neuroparenchymal loss. Hydrocephalus related to obstruction of the lateral apertures of the fourth ventricles has rarely been described. The clinicopathologic findings in two dogs with hydrocephalus secondary to obstruction of the lateral apertures of the fourth ventricle are reported. Signs were associated with a caudal cervical spinal cord lesion in one dog and a caudal brain stem lesion in the other dog. Magnetic resonance imaging (MRI) disclosed dilation of the ventricular system, including the lateral recesses of the fourth ventricle. In one dog, postmortem ventriculography confirmed obstruction of the lateral apertures. Microscopic changes were identified in the choroid plexus in both dogs, yet a definitive cause of the obstructions was not identified. The MRI findings in both dogs are similar to membranous occlusion of the lateral and median apertures in human patients. MRI detection of dilation of the entire ventricular system in the absence of an identifiable cause should prompt consideration of an obstruction of the lateral apertures. In future cases, therapeutic interventions aimed at re-establishing CSF flow or ventriculoperitoneal catheterisation should be considered. © 2016 Australian Veterinary Association.
Outcomes of HeartWare Ventricular Assist System support in 141 patients: a single-centre experience.
Wu, Long; Weng, Yu-Guo; Dong, Nian-Guo; Krabatsch, Thomas; Stepanenko, Alexander; Hennig, Ewald; Hetzer, Roland
2013-07-01
A third-generation ventricular assist device, the HeartWare Ventricular Assist System, has demonstrated its reliability and durability in animal models and clinical experience. However, studies of a large series of applications are still lacking. We evaluate the safety and efficacy of the HeartWare pump in 141 patients with end-stage heart failure at a single centre. A total of 141 patients (116 men and 25 women with a mean age of 52 years) in New York Heart Association (NYHA) Class IV received implantation of the HeartWare Ventricular Assist System between August 2009 and April 2011 at the Deutsches Herzzentrum Berlin. The outcomes were measured in terms of laboratory data, adverse events, NYHA functional class and survival during device support. The HeartWare system provided an adequate haemodynamic support for patients both inside and outside the hospital. NYHA class improved to I-II. Organ function and pulmonary vascular resistance improved significantly. In this cohort of patients, 14 patients underwent heart transplantation, one had had the device explanted following myocardial recovery, one had changed to another assist device, 81 were on ongoing support and 44 died. The overall actuarial survival rates at 6 and 12 months were 70 and 67%, respectively, and the 3-, 6- and 12-month survival rates on a left ventricular assist device (LVAD) support for bridge to transplantation patients were 82, 81 and 79%, respectively. Infection and bleeding were the main adverse events. Four patients underwent an LVAD exchange for pump thrombosis. The HeartWare system provides a safe and effective circulatory support in a population with a wide range of body surface areas, with a satisfactory actuarial survival time and an improved quality of life. It can be used for univentricular or biventricular support, being implanted into the pericardial space with simplified surgical techniques.
Catecholaminergic and serotoninergic fibres innervate the ventricular system of the hedgehog CNS.
Michaloudi, H C; Papadopoulos, G C
1996-01-01
Immunocytochemistry with antisera against serotonin (5-HT), dopamine (DA) and noradrenaline (NA) was used to detect monoaminergic (MA) fibres in the ventricular system of the hedgehog Erinaceus europaeus. Light microscopic examination of immunocytochemically stained sections revealed that the ventricular system of the hedgehog is unique among mammals in that the choroid plexuses receive CA axons and that the supraependyma and subependyma of the cerebral ventricles and the spinal central canal are innervated both by serotoninergic and catecholaminergic (CA) fibres. Supraependymal 5-HT axons were generally more abundant and created at places a large number of interconnected basket-like structures, whereas CA fibres were usually directed towards the ventricular lumen. In the lateral ventricles, CA fibres were more numerous in the ependyma lining grey matter, whereas a higher 5-HT innervation density was observed in the area between the corpus callosum and the caudate nucleus or the septum. In the 3rd ventricle, the ependyma of its dorsal part exhibited a higher 5-HT and NA innervation density, whereas DA fibres were preferentially distributed in the ventral half of the basal region. The ependyma lining the cerebral aqueduct displayed a higher MA innervation density in its ventral part. The ependymal wall of the 4th ventricle exhibited an extremely dense 5-HT innervation, mainly in the floor of the ventricle, relatively fewer NA fibres and only sparse DA ones. Few NA and relatively more 5-HT fibres were detected in the ependyma of the central canal. Finally, the circumventricular organs were unevenly innervated by the 3 types of MA fibres. The extensive monoaminergic innervation of the hedgehog ventricular system described here probably reflects a transitory evolutionary stage in the phylogeny of the MA systems with presently unknown functional implications. Images Fig. 1 Fig. 2 Figs 3-8 Figs 9-14 Figs 15-20 PMID:8886949
In vitro characterization of a magnetically suspended continuous flow ventricular assist device.
Kim, H C; Bearnson, G B; Khanwilkar, P S; Olsen, D B; Maslen, E H; Allaire, P E
1995-01-01
A magnetically suspended continuous flow ventricular assist device using magnetic bearings was developed aiming at an implantable ventricular assist device. The main advantage of this device includes no mechanical wear and minimal chance of blood trauma such, as thrombosis and hemolysis, because there is no mechanical contact between the stationary and rotating parts. The total system consists of two subsystems: the centrifugal pump and the magnetic bearing. The centrifugal pump is comprised of a 4 vane logarithmic spiral radial flow impeller and a brushless DC motor with slotless stator, driven by the back emf commutation scheme. Two radial and one thrust magnetic bearing that dynamically controls the position of the rotor in a radial and axial direction, respectively, contains magnetic coils, the rotor's position sensors, and feedback electronic control system. The magnetic bearing system was able to successfully suspend a 365.5g rotating part in space and sustain it for up to 5000 rpm of rotation. Average force-current square factor of the magnetic bearing was measured as 0.48 and 0.44 (kg-f/Amp2) for radial and thrust bearing, respectively. The integrated system demonstrated adequate performance in mock circulation tests by providing a 6 L/min flow rate against 100 mmHg differential pressure at 2300 rpm. Based on these in vitro performance test results, long-term clinical application of the magnetically suspended continuous flow ventricular assist device is very promising after system optimization with a hybrid system using both active (electromagnet) and passive (permanent magnets) magnet bearings.
Quantification of intraventricular blood clot in MR-guided focused ultrasound surgery
NASA Astrophysics Data System (ADS)
Hess, Maggie; Looi, Thomas; Lasso, Andras; Fichtinger, Gabor; Drake, James
2015-03-01
Intraventricular hemorrhage (IVH) affects nearly 15% of preterm infants. It can lead to ventricular dilation and cognitive impairment. To ablate IVH clots, MR-guided focused ultrasound surgery (MRgFUS) is investigated. This procedure requires accurate, fast and consistent quantification of ventricle and clot volumes. We developed a semi-autonomous segmentation (SAS) algorithm for measuring changes in the ventricle and clot volumes. Images are normalized, and then ventricle and clot masks are registered to the images. Voxels of the registered masks and voxels obtained by thresholding the normalized images are used as seed points for competitive region growing, which provides the final segmentation. The user selects the areas of interest for correspondence after thresholding and these selections are the final seeds for region growing. SAS was evaluated on an IVH porcine model. SAS was compared to ground truth manual segmentation (MS) for accuracy, efficiency, and consistency. Accuracy was determined by comparing clot and ventricle volumes produced by SAS and MS, and comparing contours by calculating 95% Hausdorff distances between the two labels. In Two-One-Sided Test, SAS and MS were found to be significantly equivalent (p < 0.01). SAS on average was found to be 15 times faster than MS (p < 0.01). Consistency was determined by repeated segmentation of the same image by both SAS and manual methods, SAS being significantly more consistent than MS (p < 0.05). SAS is a viable method to quantify the IVH clot and the lateral brain ventricles and it is serving in a large-scale porcine study of MRgFUS treatment of IVH clot lysis.
Irusta, Unai; Morgado, Eduardo; Aramendi, Elisabete; Ayala, Unai; Wik, Lars; Kramer-Johansen, Jo; Eftestøl, Trygve; Alonso-Atienza, Felipe
2016-01-01
Early recognition of ventricular fibrillation (VF) and electrical therapy are key for the survival of out-of-hospital cardiac arrest (OHCA) patients treated with automated external defibrillators (AED). AED algorithms for VF-detection are customarily assessed using Holter recordings from public electrocardiogram (ECG) databases, which may be different from the ECG seen during OHCA events. This study evaluates VF-detection using data from both OHCA patients and public Holter recordings. ECG-segments of 4-s and 8-s duration were analyzed. For each segment 30 features were computed and fed to state of the art machine learning (ML) algorithms. ML-algorithms with built-in feature selection capabilities were used to determine the optimal feature subsets for both databases. Patient-wise bootstrap techniques were used to evaluate algorithm performance in terms of sensitivity (Se), specificity (Sp) and balanced error rate (BER). Performance was significantly better for public data with a mean Se of 96.6%, Sp of 98.8% and BER 2.2% compared to a mean Se of 94.7%, Sp of 96.5% and BER 4.4% for OHCA data. OHCA data required two times more features than the data from public databases for an accurate detection (6 vs 3). No significant differences in performance were found for different segment lengths, the BER differences were below 0.5-points in all cases. Our results show that VF-detection is more challenging for OHCA data than for data from public databases, and that accurate VF-detection is possible with segments as short as 4-s. PMID:27441719
Figuera, Carlos; Irusta, Unai; Morgado, Eduardo; Aramendi, Elisabete; Ayala, Unai; Wik, Lars; Kramer-Johansen, Jo; Eftestøl, Trygve; Alonso-Atienza, Felipe
2016-01-01
Early recognition of ventricular fibrillation (VF) and electrical therapy are key for the survival of out-of-hospital cardiac arrest (OHCA) patients treated with automated external defibrillators (AED). AED algorithms for VF-detection are customarily assessed using Holter recordings from public electrocardiogram (ECG) databases, which may be different from the ECG seen during OHCA events. This study evaluates VF-detection using data from both OHCA patients and public Holter recordings. ECG-segments of 4-s and 8-s duration were analyzed. For each segment 30 features were computed and fed to state of the art machine learning (ML) algorithms. ML-algorithms with built-in feature selection capabilities were used to determine the optimal feature subsets for both databases. Patient-wise bootstrap techniques were used to evaluate algorithm performance in terms of sensitivity (Se), specificity (Sp) and balanced error rate (BER). Performance was significantly better for public data with a mean Se of 96.6%, Sp of 98.8% and BER 2.2% compared to a mean Se of 94.7%, Sp of 96.5% and BER 4.4% for OHCA data. OHCA data required two times more features than the data from public databases for an accurate detection (6 vs 3). No significant differences in performance were found for different segment lengths, the BER differences were below 0.5-points in all cases. Our results show that VF-detection is more challenging for OHCA data than for data from public databases, and that accurate VF-detection is possible with segments as short as 4-s.
Yen, Chih-Hsuan; Hung, Chung-Lieh; Lee, Ping-Ying; Tsai, Jui-Peng; Lai, Yau-Huei; Su, Cheng-Huang; Yeh, Hung-I; Hou, Charles Jia-Yin; Chien, Kuo-Liong
2017-01-01
Central arterial stiffness has been shown to play a key role in cardiovascular disease. However, evidence regarding such arterial stiffness from various arterial segments in relation to B-type natriuretic peptide (BNP) remains elusive. A total of 1255 participants (47.8% men; mean age: 62.6 ± 12.3 [SD] years) with preserved left ventricular function (ejection fraction ≥50%) and ≥1 risk factors were consecutively studied. Arterial pulse wave velocity (PWV) by automatic device (VP-2000; Omron Healthcare) for heart-femoral (hf-PWV), brachial-ankle (ba-PWV), and heart-carotid (hc-PWV) segments were obtained and related to BNP concentrations (Abbott Diagnostics, Abbott Park, IL, USA). Subjects in the highest hf-PWV quartile were older and had worse renal function and higher blood pressure (all P < 0.05). Elevated PWV (m/s) was correlated with elevated BNP (pg/ml) (beta coefficient = 19.3, 12.4, 5.9 for hf-PWV, ba-PWV, hc-PWV respectively, all p < 0.05). After accounting for clinical co-variates and left ventricle mass index (LVMI), both hf-PWV and ba-PWV were correlated with higher BNP (beta coefficient = 8.3, 6.4 respectively, P < 0.01 for each). Adding both hf-PWV and ba-PWV to LVMI significantly expanded ROC in predicting abnormal BNP>100 pg/ml (both P < 0.01), but only hf-PWV presented significant integrated discrimination improvement to predict risk for BNP concentrations (0.7%, P = 0.029). A significant segmental PWV associated with biomarker BNP concentrations suggests that arterial stiffness is associated with myocardial damage.
Yen, Chih-Hsuan; Hung, Chung-Lieh; Lee, Ping-Ying; Tsai, Jui-Peng; Lai, Yau-Huei; Su, Cheng-Huang; Yeh, Hung-I; Hou, Charles Jia-Yin
2017-01-01
Background Central arterial stiffness has been shown to play a key role in cardiovascular disease. However, evidence regarding such arterial stiffness from various arterial segments in relation to B-type natriuretic peptide (BNP) remains elusive. Methods A total of 1255 participants (47.8% men; mean age: 62.6 ± 12.3 [SD] years) with preserved left ventricular function (ejection fraction ≥50%) and ≥1 risk factors were consecutively studied. Arterial pulse wave velocity (PWV) by automatic device (VP-2000; Omron Healthcare) for heart-femoral (hf-PWV), brachial-ankle (ba-PWV), and heart-carotid (hc-PWV) segments were obtained and related to BNP concentrations (Abbott Diagnostics, Abbott Park, IL, USA). Results Subjects in the highest hf-PWV quartile were older and had worse renal function and higher blood pressure (all P < 0.05). Elevated PWV (m/s) was correlated with elevated BNP (pg/ml) (beta coefficient = 19.3, 12.4, 5.9 for hf-PWV, ba-PWV, hc-PWV respectively, all p < 0.05). After accounting for clinical co-variates and left ventricle mass index (LVMI), both hf-PWV and ba-PWV were correlated with higher BNP (beta coefficient = 8.3, 6.4 respectively, P < 0.01 for each). Adding both hf-PWV and ba-PWV to LVMI significantly expanded ROC in predicting abnormal BNP>100 pg/ml (both P < 0.01), but only hf-PWV presented significant integrated discrimination improvement to predict risk for BNP concentrations (0.7%, P = 0.029). Conclusion A significant segmental PWV associated with biomarker BNP concentrations suggests that arterial stiffness is associated with myocardial damage. PMID:28922407
Automatic Parameterization Strategy for Cardiac Electrophysiology Simulations.
Costa, Caroline Mendonca; Hoetzl, Elena; Rocha, Bernardo Martins; Prassl, Anton J; Plank, Gernot
2013-10-01
Driven by recent advances in medical imaging, image segmentation and numerical techniques, computer models of ventricular electrophysiology account for increasingly finer levels of anatomical and biophysical detail. However, considering the large number of model parameters involved parameterization poses a major challenge. A minimum requirement in combined experimental and modeling studies is to achieve good agreement in activation and repolarization sequences between model and experiment or patient data. In this study, we propose basic techniques which aid in determining bidomain parameters to match activation sequences. An iterative parameterization algorithm is implemented which determines appropriate bulk conductivities which yield prescribed velocities. In addition, a method is proposed for splitting the computed bulk conductivities into individual bidomain conductivities by prescribing anisotropy ratios.
Kamada, Tomohito; Hayashi, Mutsuharu; Yokoi, Hiroatsu; Fujiwara, Wakaya; Yoshikawa, Daiji; Mukaide, Daisuke; Sugishita, Yoshinori; Yoshinaga, Masataka; Ito, Takehiro; Ozaki, Yukio; Izawa, Hideo
2015-01-01
Takotsubo cardiomyopathy is a disorder characterized by left ventricular apical ballooning with preceding emotional and/or physical stressors. This condition is also an important differential diagnosis of acute coronary syndrome. We herein describe a case of Takotsubo cardiomyopathy, a significant clinical phenomenon, triggered by delayed-onset rhabdomyolysis following the administration of long-term statin treatment, without any preceding stressors or changes in the patient's medical condition, in association with complaints of non-specific muscle-related symptoms. Although an electrocardiogram showed remarkable ST-segment elevation, a careful reading of the electrocardiogram findings revealed the features of Takotsubo cardiomyopathy. Withdrawing the statin therapy improved the patient's cardiac function.
Cardiac MRI-confirmed mesalamine-induced myocarditis.
Baker, William L; Saulsberry, Whitney J; Elliott, Kaitlyn; Parker, Matthew W
2015-09-04
A 38-year-old Caucasian man with a medical history significant for inflammatory bowel disease (IBD) and mesalamine use presented to the emergency department with stabbing, pleuritic, substernal chest pain over the previous 2 days. Findings of leucocytosis, elevated cardiac enzymes and inflammatory markers, T-wave or ST-segment abnormalities and left ventricular systolic dysfunction suggested mesalamine-induced myocarditis. However, a cardiac MRI confirmed the diagnosis. Signs and symptoms improved within days of withdrawal of mesalamine, and initiation of corticosteroids and follow-up studies within the next year were unremarkable. Importantly, the diagnosis of mesalamine-induced myocarditis confirmed via cardiac MRI is a step rarely performed in published cases. 2015 BMJ Publishing Group Ltd.
Mortazavi, M M; Adeeb, N; Griessenauer, C J; Sheikh, H; Shahidi, S; Tubbs, R I; Tubbs, R S
2014-01-01
The cerebral ventricles have been recognized since ancient medical history. Their true function started to be realized more than a thousand years later. Their anatomy and function are extremely important in the neurosurgical panorama. The literature was searched for articles and textbooks of different topics related to the history, anatomy, physiology, histology, embryology and surgical considerations of the brain ventricles. Herein, we summarize the literature about the cerebral ventricular system.
Kırış, Abdulkadir; Kırış, Gülhanım; Karaman, Kayıhan; Sahin, Mürsel; Gedikli, Omer; Kaplan, Sahin; Orem, Asım; Kutlu, Merih; Kazaz, Zeynep
2012-10-01
Left ventricular (LV) dyssynchrony is a common finding in patients with hypertension and is associated with LV hypertrophy. Arterial stiffness (AS) and central (aortic) blood pressures play a significant role in end-organ damage such as LV hypertrophy caused by hypertension. The objective of this study was to investigate the relationship between AS, central blood pressures (BP) and LV dyssynchrony. Thirty-five newly diagnosed hypertensive patients and 40 controls were enrolled in the study. The entire study population underwent a comprehensive echocardiographic study including tissue synchrony imaging. The 12 segmental model was used to measure the time to regional peak systolic tissue velocity (Ts) in the LV and two dyssynchrony indices were computed. Parameters of AS including pulse wave velocity (PWV), augmentation index (AIx@75), and central systolic and diastolic BP were evaluated by applanation tonometry. The baseline clinical and echocardiographic parameters of both groups were similar except for their BPs. Dyssynchrony indices were prolonged in patients with hypertension as compared to the controls. The standart deviation of Ts of 12 LV segments in patients with hypertension and the controls were 48.7±18.8 vs. 25.8±13.1, respectively (p<0.001), and the maximal difference in Ts between any 2 of 12 LV segments was 143.9±52.2 for hypertension patients vs. 83.8±39.4 for controls (p<0.001). PWV (11.9±2.5 vs. 9.5±1.4, p<0.001), AIx@75 (27.4±8.3 vs. 18.3±9, p=0.009), and central systolic (147.6±20.8 vs. 105.4±11, p<0.001) and diastolic (99.8±14.4 vs. 72.8±9.5, p<0.001) pressures were higher in patients with hypertension than in the controls, respectively. In multivariable analysis, central systolic BP (ß=0.496, p=0.03), LV mass index (ß=0.232, p=0.027), and body mass index (ß=0.308, p=0.002) were found to be independently related to dyssynchrony. Central systolic BP is an independent predictor of LV dyssynchrony, but Aıx@75 did not have an independent effect on LV synchronicity in patients with newly-diagnosed hypertension.
A Successful Anticoagulation Protocol for the First HeartMate® II Implantation in the United States
Amir, Offer; Bracey, Arthur W.; Smart, Frank W.; Delgado, Reynolds M.; Shah, Nyma; Kar, Biswajit; Gregoric, Igor D.
2005-01-01
Bleeding and thrombus formation are common problems with life-threatening implications in patients receiving a left ventricular assist device. We describe the anticoagulation protocol for the 1st patient in the United States to undergo successful implantation of the HeartMate® II left ventricular assist system. PMID:16392229
Response of the Cardiovascular System to Vibration and Combined Stresses
1975-08-31
Canines were chronically instrumented for continuous measurements of ascending aortic flow ( Zepeda ), left ventricular pressure (Konigsberg), circum- flex...different animals. Each dog was chronically instrumented for continuous measuremernt of ascending aortic flow ( Zepeda ), left ventricular pressure...vibration protocol as those animals restrained vertically. METHODS Canines (16 to 22 kg) were chronically instrumented with electromagnetic flow cuffs ( Zepeda
Research and Development of Advanced Life Support Equipment.
1999-02-01
kg.) were catheterized f or measurement of left ventricular pressure (LVP), right ventricular pressure (RVP), mean aortic pressure (MAP), central ...Orientation Laboratory Venous Gas Emboli Variable Profile Breathing Simulator Wingate Anaerobic Test Weapons System Trainer World Wide Web... history screening of the potential subjects was conducted to eliminate those individuals who have known health conditions/ histories which would
Sugiyama, Atsushi; Takahara, Akira; Yatomi, Yutaka; Satoh, Yoshioki; Nakamura, Yuji; Hashimoto, Keitaro
2003-06-01
Given the limited information, physiological roles of Rho-kinase in the cardiac conduction system and ventricular repolarization process were assessed in comparison with those in the coronary vascular tone. A specific Rho-kinase inhibitor Y-27632 was administered to the nutrient coronary artery of the canine isolated, blood-perfused atrioventricular node preparation under the monitoring of the ventricular monophasic action potentials. Administration of Y-27632 moderately suppressed the atrioventricular nodal conduction, slightly but significantly accelerated the repolarization process, and potently increased the coronary blood flow, whereas it hardly affected the intraventricular conduction. The estimated concentrations of Y-27632 causing the currently observed effects were enough to inhibit Rho-kinase. These results suggest that constitutional Rho-kinase functions to moderately facilitate the atrioventricular nodal conduction, slightly delay ventricular repolarization process, and significantly increase the coronary vascular tone.
NASA Astrophysics Data System (ADS)
Reed, Judd E.; Rumberger, John A.; Buithieu, Jean; Behrenbeck, Thomas; Breen, Jerome F.; Sheedy, Patrick F., II
1995-05-01
Following myocardial infarction, the size of the infarcted region and the systolic functioning of the noninfarcted region are commonly assessed by various cross- sectional imaging techniques. A series of images representing successive phases of the cardiac cycle can be acquired by several imaging modalities including electron beam computed tomography, magnetic resonance imaging, and echocardiography. For the assessment of patterns of ventricular contraction, images are commonly acquired of ventricular cross-sections normal to the 'long' axis of the heart and parallel to the mitral valve plane. The endocardial and epicardial surfaces of the myocardium are identified. Then the ventricle is divided into sectors and the volumes of blood and myocardium within each sector at multiple phases of the cardiac cycle are measured. Regional function parameters are derived from these measurements. This generally mandates the use of a polar or cylindrical coordinate system. Various algorithms have been used to select the origin of this coordinate system. These include the centroid of the endocardial surface, the epicardial surface, or of a polygon whose vertices lie midway between the epicardial and endocardial surfaces of the myocardium (centerline method). Another algorithm has been developed in our laboratory. This uses the centroid (or center of mass) of the myocardium exclusive of the ventricular cavity. Each of these choices for origin of coordinate system can be derived from the end- diastolic image or from the end-systolic image. Alternately, new coordinate systems can be selected for each phase of the cardiac cycle. These are referred to as 'floating' coordinate systems. A series of computer models have been developed in our laboratory to study the effects of each of these choices on the regional function parameters of normal ventricles and how these choices effect the quantification of regional abnormalities after myocardial infarction. The most sophisticated of these is an interactive program with a graphical user interface which facilitates the simulation of a wide variety of dynamic ventricular cross sections. Analysis of these simulations has led to a better understanding of how polar coordinate system placement influences the results of quantitative regional ventricular function assessment. It has also created new insight into how the appropriateness of the placement of such a polar coordinate systems can be objectively assessed. The validity of the conclusions drawn from the analysis of simulated ventricular shapes was validated through the analysis of outlines extracted from cine electron beam computed tomographic images. This was done using another interactive software tool developed specifically for this purpose. With this tool, the effects on regional function parameters of various choices for origin placement can be directly observed. This has proven to reinforce the conclusions drawn from the simulations and has led to the modification of the procedures used in our laboratory. Conclusions: The so-called floating coordinate systems are superior to fixed ones for quantification of regional left ventricular contraction in almost every respect. The use of regional ejection fractions with a coordinate system origin located at the centroid of the endocardial surface can lead to 180 degree errors in identifying the location of a myocardial infarction. This problem is less pronounced with midline and epicardium- based centroids and does not occur when the centroid of the myocardium is used. The quantified migration of myocardial mass across sector boundaries is a useful indicator of an inappropriate choice of coordinate system origin. When the centroid of the myocardium falls well within the ventricular cavity, as it usually does, it is a better location for the origin for regional analysis than any of the other centroids analyzed.
Sack, Kevin L; Dabiri, Yaghoub; Franz, Thomas; Solomon, Scott D; Burkhoff, Daniel; Guccione, Julius M
2018-01-01
Predictive computation models offer the potential to uncover the mechanisms of treatments whose actions cannot be easily determined by experimental or imaging techniques. This is particularly relevant for investigating left ventricular mechanical assistance, a therapy for end-stage heart failure, which is increasingly used as more than just a bridge-to-transplant therapy. The high incidence of right ventricular failure following left ventricular assistance reflects an undesired consequence of treatment, which has been hypothesized to be related to the mechanical interdependence between the two ventricles. To investigate the implication of this interdependence specifically in the setting of left ventricular assistance device (LVAD) support, we introduce a patient-specific finite-element model of dilated chronic heart failure. The model geometry and material parameters were calibrated using patient-specific clinical data, producing a mechanical surrogate of the failing in vivo heart that models its dynamic strain and stress throughout the cardiac cycle. The model of the heart was coupled to lumped-parameter circulatory systems to simulate realistic ventricular loading conditions. Finally, the impact of ventricular assistance was investigated by incorporating a pump with pressure-flow characteristics of an LVAD (HeartMate II™ operating between 8 and 12 k RPM) in parallel to the left ventricle. This allowed us to investigate the mechanical impact of acute left ventricular assistance at multiple operating-speeds on right ventricular mechanics and septal wall motion. Our findings show that left ventricular assistance reduces myofiber stress in the left ventricle and, to a lesser extent, right ventricle free wall, while increasing leftward septal-shift with increased operating-speeds. These effects were achieved with secondary, potentially negative effects on the interventricular septum which showed that support from LVADs, introduces unnatural bending of the septum and with it, increased localized stress regions. Left ventricular assistance unloads the left ventricle significantly and shifts the right ventricular pressure-volume-loop toward larger volumes and higher pressures; a consequence of left-to-right ventricular interactions and a leftward septal shift. The methods and results described in the present study are a meaningful advancement of computational efforts to investigate heart-failure therapies in silico and illustrate the potential of computational models to aid understanding of complex mechanical and hemodynamic effects of new therapies.
Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc
2014-05-01
Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maier, Joscha, E-mail: joscha.maier@dkfz.de; Sawall, Stefan; Kachelrieß, Marc
2014-05-15
Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levelsmore » from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. Conclusions: LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart.« less
Aguiar Rosa, Silvia; Timóteo, Ana Teresa; Ferreira, Lurdes; Carvalho, Ramiro; Oliveira, Mario; Cunha, Pedro; Viveiros Monteiro, André; Portugal, Guilherme; Almeida Morais, Luis; Daniel, Pedro; Cruz Ferreira, Rui
2018-04-01
The aim was to characterise acute coronary syndrome patients with complete atrioventricular block and to assess the effect on outcome. Patients admitted with acute coronary syndrome were divided according to the presence of complete atrioventricular block: group 1, with complete atrioventricular block; group 2, without complete atrioventricular block. Clinical, electrocardiographic and echocardiographic characteristics and prognosis during one year follow-up were compared between the groups. Among 4799 acute coronary syndrome patients admitted during the study period, 91 (1.9%) presented with complete atrioventricular block. At presentation, group 1 patients presented with lower systolic blood pressure, higher Killip class and incidence of syncope. In group 1, 86.8% presented with ST-segment elevation myocardial infarction (STEMI), and inferior STEMI was verified in 79.1% of patients in group 1 compared with 21.9% in group 2 ( P<0.001). Right ventricular myocardial infarction was more frequent in group 1 (3.3% vs. 0.2%; P<0.001). Among patients who underwent fibrinolysis complete atrioventricular block was observed in 7.3% in contrast to 2.5% in patients submitted to primary percutaneous coronary intervention ( P<0.001). During hospitalisation group 1 had worse outcomes, with a higher incidence of cardiogenic shock (33.0% vs. 4.5%; P<0.001), ventricular arrhythmias (17.6% vs. 3.6%; P<0.001) and the need for invasive mechanical ventilation (25.3% vs. 5.1%; P<0.001). After a propensity score analysis, in a multivariate regression model, complete atrioventricular block was an independent predictor of hospital mortality (odds ratio 3.671; P=0.045). There was no significant difference in mortality at one-year follow-up between the study groups. Complete atrioventricular block conferred a worse outcome during hospitalisation, including a higher incidence of cardiogenic shock, ventricular arrhythmias and death.
Sirvente, Raquel A.; Irigoyen, Maria C.; Souza, Leandro E.; Mostarda, Cristiano; La Fuente, Raquel N.; Candido, Georgia O.; Souza, Pamella R. M.; Medeiros, Alessandra; Mady, Charles; Salemi, Vera M. C.
2014-01-01
Background Sympathetic hyperactivity may be related to left ventricular (LV) dysfunction and baro- and chemoreflex impairment in hypertension. However, cardiac function, regarding the association of hypertension and baroreflex dysfunction, has not been previously evaluated by transesophageal echocardiography (TEE) using intracardiac echocardiographic catheter. Methods and Results We evaluated exercise tests, baroreflex sensitivity and cardiovascular autonomic control, cardiac function, and biventricular invasive pressures in rats 10 weeks after sinoaortic denervation (SAD). The rats (n = 32) were divided into 4 groups: 16 Wistar (W) with (n = 8) or without SAD (n = 8) and 16 spontaneously hypertensive rats (SHR) with (n = 8) or without SAD (SHRSAD) (n = 8). Blood pressure (BP) and heart rate (HR) did not change between the groups with or without SAD; however, compared to W, SHR groups had higher BP levels and BP variability was increased. Exercise testing showed that SHR had better functional capacity compared to SAD and SHRSAD. Echocardiography showed left ventricular (LV) concentric hypertrophy; segmental systolic and diastolic biventricular dysfunction; indirect signals of pulmonary arterial hypertension, mostly evident in SHRSAD. The end-diastolic right ventricular (RV) pressure increased in all groups compared to W, and the end-diastolic LV pressure increased in SHR and SHRSAD groups compared to W, and in SHRSAD compared to SAD. Conclusions Our results suggest that baroreflex dysfunction impairs cardiac function, and increases pulmonary artery pressure, supporting a role for baroreflex dysfunction in the pathogenesis of hypertensive cardiac disease. Moreover, TEE is a useful and feasible noninvasive technique that allows the assessment of cardiac function, particularly RV indices in this model of cardiac disease. PMID:24828834
Bernheim, Alain M; Nakajima, Yoshie; Pellikka, Patricia A
2008-10-01
Exercise testing is often normal despite the presence of exertional symptoms. We hypothesized that left ventricular (LV) dyssynchrony might occur in some patients in the absence of ischemia, LV dysfunction, or wide QRS, and might contribute to exertional symptoms and diminished exercise capacity. Echocardiographic parameters were assessed before and with exercise in 40 patients (age 62 +/- 8 years, 27 with exertional symptoms). All had normal clinically indicated exercise echocardiograms and narrow QRS. The time to peak systolic velocity (Ts) was measured in 12 segments to calculate the standard deviation (Ts-SD) and the maximal difference (Ts-diff). At rest, 25 patients (63%) had dyssynchrony by Ts-SD. With exercise, mean Ts-SD did not increase significantly (34.9 +/- 19.3 ms vs 39.5 +/- 27.2 ms, P = .28). However, Ts-SD increased by greater than 40% in 15 patients (37.5%), remained stable in 19 patients (47.5%), and decreased by greater than 40% in 6 patients (15%). Similar responses were observed for Ts-diff. Patients with exercise-induced dyssynchrony were not more likely to have symptoms. Exercise capacity was inversely correlated with resting Ts-SD (r = -0.37, P = .02) and resting Ts-diff (r = -0.38, P = .02), but not with exercise-induced changes in dyssynchrony. Patients with resting dyssynchrony had higher resting heart rate (73 +/- 12 vs 63 +/- 11 beats/min, P = .02). LV dyssynchrony may occur more frequently than previously thought and may develop with exercise in the absence of ischemia. Exercise-induced LV dyssynchrony was not related to exertional symptoms or exercise capacity. Patients with dyssynchrony at rest had a higher resting heart rate and achieved a lower workload; this may indicate early myocardial impairment.
van der Bijl, Pieter; Khidir, Mand Jh; Leung, Melissa; Yilmaz, Dilek; Mertens, Bart; Marsan, Nina Ajmone; Delgado, Victoria; Bax, Jeroen J
2018-05-09
In heart failure (HF) patients, left ventricular mechanical dispersion (LVMD) reflects heterogeneous mechanical activation of the left ventricle. In HF patients, LVMD can be reduced after CRT. Whether lesser LVMD is associated with improved outcome is unknown. To relate LVMD to long-term prognosis in a large cohort of HF patients after 6 months of cardiac resynchronization therapy (CRT). Clinical, echocardiographic and ventricular arrhythmia (VA) data were analyzed from an ongoing registry of HF recipients of CRT. Baseline (prior to CRT) and 6-month echocardiograms were evaluated. LVMD was calculated as the standard deviation of the time from onset of the QRS complex to the peak longitudinal strain in a 17-segment model. Patients were divided into two groups, according to the median LVMD (84 ms) at 6 months post-CRT. Of 1,185 patients (mean age 65±10 years, 76% male), 343 (29%) died during a mean follow-up of 55±36 months. Baseline LVMD was not associated with all-cause mortality and VA at follow-up. In contrast, patients with less LVMD (≤84 ms) at 6 months post-CRT had lower event rates (VA and mortality) compared to those with LVMD >84 ms. On multivariable analysis, greater LVMD at 6 months after CRT was independently associated with an increased risk of mortality (hazard ratio, 1.002; P=0.037) and VA (hazard ratio, 1.003; P=0.026) . Larger LVMD at 6 months after CRT is independently associated with all-cause mortality and VA. LVMD may be valuable in identifying patients who remain at high mortality risk after CRT implantation. Copyright © 2018. Published by Elsevier Inc.
Cardiac Structure and Function in Cushing's Syndrome: A Cardiac Magnetic Resonance Imaging Study
Roux, Charles; Salenave, Sylvie; Kachenoura, Nadjia; Raissouni, Zainab; Macron, Laurent; Guignat, Laurence; Jublanc, Christel; Azarine, Arshid; Brailly, Sylvie; Young, Jacques; Mousseaux, Elie; Chanson, Philippe
2014-01-01
Background: Patients with Cushing's syndrome have left ventricular (LV) hypertrophy and dysfunction on echocardiography, but echo-based measurements may have limited accuracy in obese patients. No data are available on right ventricular (RV) and left atrial (LA) size and function in these patients. Objectives: The objective of the study was to evaluate LV, RV, and LA structure and function in patients with Cushing's syndrome by means of cardiac magnetic resonance, currently the reference modality in assessment of cardiac geometry and function. Methods: Eighteen patients with active Cushing's syndrome and 18 volunteers matched for age, sex, and body mass index were studied by cardiac magnetic resonance. The imaging was repeated in the patients 6 months (range 2–12 mo) after the treatment of hypercortisolism. Results: Compared with controls, patients with Cushing's syndrome had lower LV, RV, and LA ejection fractions (P < .001 for all) and increased end-diastolic LV segmental thickness (P < .001). Treatment of hypercortisolism was associated with an improvement in ventricular and atrial systolic performance, as reflected by a 15% increase in the LV ejection fraction (P = .029), a 45% increase in the LA ejection fraction (P < .001), and an 11% increase in the RV ejection fraction (P = NS). After treatment, the LV mass index and end-diastolic LV mass to volume ratio decreased by 17% (P < .001) and 10% (P = .002), respectively. None of the patients had late gadolinium myocardial enhancement. Conclusion: Cushing's syndrome is associated with subclinical biventricular and LA systolic dysfunctions that are reversible after treatment. Despite skeletal muscle atrophy, Cushing's syndrome patients have an increased LV mass, reversible upon correction of hypercortisolism. PMID:25093618