Sample records for vertical bone height

  1. Analysis of Bone Height Changes after Maxillary Sinus Augmentation with Simultaneous and Delayed Placement of Dental Implants: A Clinical and Radiographic Study.

    PubMed

    Yin, Lihua; Yu, Zhanhai; Chen, Zhuofan; Huang, Baoxin; Zhang, Kailiang; Zhou, Ailing; Li, Xiangxin

    2016-08-01

    To retrospectively assess the changes of the vertical height of the maxillary sinus floor after augmentation with simultaneous and delayed placement of implants. In total, 38 patients with 76 implants were involved; vertical bone height of the sinus floor was radiographically measured at different stages including preoperation, immediately postsurgery, 6 and 12 months postsurgery, and 6 and 24 months postfunctional loading. Sinus augmentation significantly increased vertical bone height of the sinus floor for both the simultaneous and delayed groups. The survival rate was 100% in the simultaneous group and 95.46% in the delayed group. For simultaneous placement, the vertical bone height of the sinus floor at 6 and 12 months postsurgery was significantly less than that immediately postsurgery. For both groups, augmented bone height of the sinus floor showed significant decrease from 6 months to 24 months postfunctional loading. The mean value of final bone augmentation was 5.85 mm for simultaneous placement and 5.80 mm for delayed placements. Sinus augmentation with simultaneous and delayed placement of implants led to similar survival rates and bone augmentation. Resorption of augmentative bone was evident at 24 months postfunctional loading in both cases. © 2015 by the American College of Prosthodontists.

  2. Dental implants typically help retain peri-implant vertical bone height: evidence-based analysis.

    PubMed

    Greenstein, Gary; Cavallaro, John

    2013-01-01

    The dental literature is assessed regarding the ability of dental implants to maintain vertical bone height after various implant placement scenarios: immediate, delayed, insertion into partially and fully edentate healed ridges, and under overdentures. Studies are also reviewed to determine if bone loss after implant insertion is continuous. Numerous investigations that support the concept that implants preserve bone height are identified. In addition, the data indicate that a minuscule amount of annual bone loss usually persists after implant placement, but it is often clinically imperceptible.

  3. Vertical osteoconductivity of sputtered hydroxyapatite-coated mini titanium implants after dura mater elevation: Rabbit calvarial model.

    PubMed

    Wang, Xin; Zakaria, Osama; Madi, Marwa; Kasugai, Shohei

    2015-01-01

    This study evaluated the quantity and quality of newly formed vertical bone induced by sputtered hydroxyapatite-coated titanium implants compared with sandblasted acid-etched implants after dura mater elevation. Hydroxyapatite-coated and non-coated implants (n = 20/group) were used and divided equally into two groups. All implants were randomly placed into rabbit calvarial bone (four implants for each animal) emerging from the inferior cortical layer, displacing the dura mater 3 mm below the original bone. Animals were sacrificed at 4 (n = 5) and 8 (n = 5) weeks post-surgery. Vertical bone height and area were analyzed histologically and radiographically below the original bone. Vertical bone formation was observed in both groups. At 4 and 8 weeks, vertical bone height reached a significantly higher level in the hydroxyapatite compared with the non-coated group (p < 0.05). Vertical bone area was significantly larger in the hydroxyapatite compared with the non-coated group at 4 and 8 weeks (p < 0.05). This study indicates that vertical bone formation can be induced by dura mater elevation and sputtered hydroxyapatite coating can enhance vertical bone formation.

  4. Effect of Alveolar Segmental Sandwich Osteotomy on Alveolar Height: A Preliminary Study.

    PubMed

    Mehta, Karan S; Prasad, Kavitha; Shetty, Vibha; Ranganath, Krishnappa; Lalitha, R M; Dexith, Jayashree; Munoyath, Sejal K; Kumar, Vineeth

    2017-12-01

    Bone loss following extraction is maximum in horizontal dimension. Height is also reduced which is pronounced on the buccal aspect. Various surgical procedures are available to correct the bone volume viz. GBR, onlay bone grafting, alveolar distraction and sandwich osteotomy. Sandwich osteotomy has been found to increase the vertical alveolar bone height successfully. The objective of the study was to assess the effect of alveolar segmental sandwich osteotomy on alveolar height and crestal width. A prospective study was undertaken from December 2012 to August 2014. Seven patients with 12 implant sites with a mean age of 36 years were recruited. All seven patients with 12 implant sites underwent alveolar segmental sandwich osteotomy and interpositional bone grafting. Alveolar bone height was assessed radiographically preoperatively, immediate post-op, and at 3 months post-op. Alveolar bone width was assessed radiographically preoperatively and at 3 months post-op. Statistical significance was inferred at p  < 0.05. The mean vertical augmentation at immediate post-op was 6.58 mm ( p  = 0.001). The vertical augmentation that was achieved 3 months post-op was a mean of 3.75 mm which was statistically significant ( p  = 0.004). The change in alveolar height from immediate post-op to 3 month post-op was a mean 1.69 mm. The mean change in alveolar crestal width at 3 months was a mean of -0.29 mm ( p  = 0.57). Sandwich osteotomy can be used as an alternative technique to increase alveolar bone height prior to implant placement. Moderate alveolar deficiency can be predictably corrected by this technique.

  5. Improvement of Implant Placement after Bone Augmentation of Severely Resorbed Maxillary Sinuses with 'Tent-Pole' Grafting Technique in Combination with rhBMP-2.

    PubMed

    Zhang, Qiao; Zhang, Li Li; Yang, Yang; Lin, Yi Zhen; Miron, Richard J; Zhang, Yu Feng

    To study the clinical effect of short implant placement using osteotome sinus floor elevation technique and tent-pole grafting technique with recombinant human bone morphogenetic protein 2 (rhBMP-2) in severely resorbed maxillary area. Eleven patients with insufficient bone height in the posterior maxillary area were included. According to the native bone height and crown height space (CHS), the patients were divided into two groups: immediate placement of short implants with simultaneous bone augmentation (group A, 5 patients) and delayed dental implant placement (4 to 6 months) after bone augmentation. The rhBMP-2 was added into a deproteinised bovine bone mineral (DBBM) bone grafting material to shorten the treatment procedure and enhance the final effect of bone augmentation in both groups. Tent-pole grafting technique was applied for vertical bone augmentation in group B (6 patients). The success rate of the implants placed was 100% in both groups. In group A, the short implants treatment was successful, with a vertical gain of 1.5 to 6.4 mm in bone height after 4 to 6 months. In group B, the tent-pole grafting procedure in combination with DBBM and rhBMP-2 increased vertical bone height between 3.1 and 8.1 mm, an optimistic and adequate increase for implant placement. This bone increase was maintained following implant placement and final crown placement in the maxillary region (3.5 to 7.3 mm). The tent-pole grafting technique was a viable alternative choice to lateral sinus floor elevation in cases with excessive CHS. The application of rhBMP-2 with a shortened treatment time demonstrated positive outcomes in sinus floor augmentation procedures.

  6. Cone-Beam Computed Tomography Evaluation of Horizontal and Vertical Dimensional Changes in Buccal Peri-Implant Alveolar Bone and Soft Tissue: A 1-Year Prospective Clinical Study.

    PubMed

    Kaminaka, Akihiro; Nakano, Tamaki; Ono, Shinji; Kato, Tokinori; Yatani, Hirofumi

    2015-10-01

    This study evaluated changes in the horizontal and vertical dimensions of the buccal alveolar bone and soft tissue over a 1-year period following implant prosthesis. Thirty-three participants with no history of guided bone regeneration or soft tissue augmentation underwent dental implant placement with different types of connections. The dimensions of the buccal alveolar bone and soft tissue were evaluated immediately and at 1 year after prosthesis from reconstructions of cross-sectional cone-beam computed tomography images. The vertical and horizontal loss of buccal bone and soft tissue around implants with conical connections were lower than around those with external or internal connections. Statistically significant negative correlations were observed between initial horizontal bone thickness and changes in vertical bone and soft tissue height (p < .05), and between initial horizontal soft tissue thickness and the change in vertical soft tissue height (p < .05). Implants with a conical connection preserve peri-implant alveolar bone and soft tissue more effectively than other connection types. Furthermore, the initial buccal alveolar bone and soft tissue thickness around the implant platform may influence their vertical dimensional changes at 1 year after implant prosthesis. © 2014 Wiley Periodicals, Inc.

  7. Peri-implant bone length changes and survival rates of implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height.

    PubMed

    Kim, Hae-Young; Yang, Jin-Yong; Chung, Bo-Yoon; Kim, Jeong Chan; Yeo, In-Sung

    2013-04-01

    The aim of this study was to measure the peri-implant bone length surrounding implants that penetrate the sinus membrane at the posterior maxilla and to evaluate the survival rate of these implants. Treatment records and orthopantomographs of 39 patients were reviewed and analyzed. The patients had partial edentulism at the posterior maxilla and limited vertical bone height below the maxillary sinus. Implants were inserted into the posterior maxilla, penetrating the sinus membrane. Four months after implant insertion, provisional resin restorations were temporarily cemented to the abutments and used for one month. Then, a final impression was taken at the abutment level, and final cement-retained restorations were delivered with mutually protected occlusion. The complications from the implant surgery were examined, the number of failed implants was counted, and the survival rate was calculated. The peri-implant bone lengths were measured using radiographs. The changes in initial and final peri-implant bone lengths were statistically analyzed. Nasal bleeding occurred after implant surgery in three patients. No other complications were found. There were no failures of the investigated implants, resulting in a survival rate of 100%. Significantly more bone gain around the implants (estimated difference=-0.6 mm, P=0.025) occurred when the initial residual bone height was less than 5 mm compared to the >5 mm groups. No significant change in peri-implant bone length was detected when the initial residual bone height was 5 mm or larger. This study suggests that implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height may be safe and functional.

  8. Large Bone Vertical Augmentation Using a Three-Dimensional Printed TCP/HA Bone Graft: A Pilot Study in Dog Mandible.

    PubMed

    Carrel, Jean-Pierre; Wiskott, Anselm; Scherrer, Susanne; Durual, Stéphane

    2016-12-01

    Osteoflux is a three-dimensional printed calcium phosphate porous structure for oral bone augmentation. It is a mechanically stable scaffold with a well-defined interconnectivity and can be readily shaped to conform to the bone bed's morphology. An animal experiment is reported whose aim was to assess the performance and safety of the scaffold in promoting vertical growth of cortical bone in the mandible. Four three-dimensional blocks (10 mm length, 5 mm width, 5 mm height) were affixed to edentulous segments of the dog's mandible and covered by a collagen membrane. During bone bed preparation, particular attention was paid not to create defects 0.5 mm or more so that the real potential of the three-dimensional block in driving vertical bone growth can be assessed. Histomorphometric analyses were performed after 8 weeks. At 8 weeks, the three-dimensional blocks led to substantial vertical bone growth up to 4.5 mm from the bone bed. Between 0 and 1 mm in height, 44% of the surface was filled with new bone, at 1 to 3 mm it was 20% to 35%, 18% at 3 to 4, and ca. 6% beyond 4 mm. New bone was evenly distributed along in mesio-distal direction and formed a new crest contour in harmony with the natural mandibular shape. After two months of healing, the three-dimensional printed blocks conducted new bone growth above its natural bed, up to 4.5 mm in a canine mandibular model. Furthermore, the new bone was evenly distributed in height and density along the block. These results are very promising and need to be further evaluated by a complete powerful study using the same model. © 2016 Wiley Periodicals, Inc.

  9. Cephalometric Evaluation of the Hyoid Bone Position in Lebanese Healthy Young Adults.

    PubMed

    Daraze, Antoine

    2018-05-01

    The objectives of this study are to assess hyoid sagittal and vertical position, and potential correlations with gender, skeletal class, and anthropometrics. Twenty-seven cephalometric linear, angular, and ratio measurements for the hyoid were recorded on lateral cephalograms obtained from 117 healthy young Lebanese adults. Anthropometric parameters including height, weight, body mass index (BMI), and neck circumference (NC) were measured. Statistically significant gender differences were demonstrated for 21 out of 27 parameters considered. All linear and two out of three angular measurements defining the vertical hyoid position were larger in males compared with females. Five linear, one angular, and two ratio measurements showed differences in the sagittal dimension. Skeletal classes did not influence the sagittal and vertical hyoid position. Anthropometric variables as height were strongly correlated to the vertical hyoid position, while weight correlated more sagittally. Cephalometric norms for hyoid position were established, sexual dimorphism and ethnic differences were demonstrated. Skeletal patterns did not influence the sagittal and vertical hyoid bone position. Anthropometric parameters, such as BMI correlated the least to both vertical and sagittal hyoid position measurements, while the impact of height and weight as separate entities made a paradigm shift providing accurate and strong correlation of the vertical hyoid position to the height, and the sagittal hyoid position to the weight of individuals. The cephalometric norms for the hyoid bone position in the Lebanese population established in the present study are of paramount clinical importance and should be considered in planning combined orthodontic and breathing disorders treatments.

  10. Evaluation of stress distribution of implant-retained mandibular overdenture with different vertical restorative spaces: A finite element analysis

    PubMed Central

    Ebadian, Behnaz; Farzin, Mahmoud; Talebi, Saeid; Khodaeian, Niloufar

    2012-01-01

    Background: Available restorative space and bar height is an important factor in stress distribution of implant-supported overdentures. The purpose of this study was to evaluate the effect of different vertical restorative spaces and different bar heights on the stress distribution around implants by 3D finite element analysis. Materials and Methods: 3D finite element models were developed from mandibular overdentures with two implants in the interforaminal region. In these models, four different bar heights from gingival crest (0.5, 1, 1.5, 2 mm) with 15 mm occlusal plane height and three different occlusal plane heights from gingival crest (9, 12, 15 mm) with 2 mm bar height were analyzed. A vertical unilateral and a bilateral load of 150 N were applied to the central occlusal fossa of the first molar and the stress of bone around implant was analyzed by finite element analysis. Results: By increasing vertical restorative space, the maximum stress values around implants were found to be decreased in unilateral loading models but slightly increased in bilateral loading cases. By increasing bar height from gingival crest, the maximum stress values around implants were found to be increased in unilateral loading models but slightly decreased in bilateral loading cases. In unilateral loading models, maximum stress was found in a model with 9 mm occlusal plane height and 1.5 mm bar height (6.254 MPa), but in bilateral loading cases, maximum stress was found in a model with 15 mm occlusal plane height and 0.5 mm bar height (3.482 MPa). Conclusion: The reduction of bar height and increase in the thickness of acrylic resin base in implant-supported overdentures are biomechanically favorable and may result in less stress in periimplant bone. PMID:23559952

  11. Analysis of occlusal vertical dimension and mandibular Basal bone height in a nigerian population.

    PubMed

    Akinbami, Babatunde O; Nsirim, Prince E

    2014-01-01

    Background. The actual basal bone height of the reconstructed mandible is relevant to achieve normal occlusal vertical dimension for the prosthesis fabricated. The purpose of the study was to determine the mean and baseline values of the occlusal vertical dimension and height of the mandibular basal bone in a Nigerian population. Method. Each participant was asked to bring the upper and lower teeth into contact, while the distance between the nasal sill and dimple on the lower lip was measured (OVD). The skin at lower border of the mandible was marked and the distance between this point and the landmark on the lower lip was measured, MBH. Result. 200 subjects were evaluated. Age range was 16-30 years, mean ± (SD), 21.6 ± (3.1) years. Males had mean ± (SD) of 42.10 ± (5.34) mm for OVD and females 39.72 ± (5.25) mm; acceptable baseline range of OVD for any population will be 34-48 mm (3.4-4.8) cm. All the males had a mean ± (SD), 30.54 ± (6.13) mm for MBH, and all the females 29.63 ± (5.23) mm. Acceptable baseline range of MBH for any population will be 24-37 mm (2.4-3.7) cm. Conclusion. To reconstruct the mandible and still maintain the OVD, heights of bone grafts must not be less than 2 cm or greater than 4 cm.

  12. Translational Research: Palatal-derived Ecto-mesenchymal Stem Cells from Human Palate: A New Hope for Alveolar Bone and Cranio-Facial Bone Reconstruction

    PubMed Central

    Grimm, Wolf Dieter; Dannan, Aous; Giesenhagen, Bernd; Schau, Ingmar; Varga, Gabor; Vukovic, Mark Alexander; Sirak, Sergey Vladimirovich

    2014-01-01

    The management of facial defects has rapidly changed in the last decade. Functional and esthetic requirements have steadily increased along with the refinements of surgery. In the case of advanced atrophy or jaw defects, extensive horizontal and vertical bone augmentation is often unavoidable to enable patients to be fitted with implants. Loss of vertical alveolar bone height is the most common cause for a non primary stability of dental implants in adults. At present, there is no ideal therapeutic approach to cure loss of vertical alveolar bone height and achieve optimal pre-implantological bone regeneration before dental implant placement. Recently, it has been found that specific populations of stem cells and/or progenitor cells could be isolated from different dental resources, namely the dental follicle, the dental pulp and the periodontal ligament. Our research group has cultured palatal-derived stem cells (paldSCs) as dentospheres and further differentiated into various cells of the neuronal and osteogenic lineage, thereby demonstrating their stem cell state. In this publication will be shown whether paldSCs could be differentiated into the osteogenic lineage and, if so, whether these cells are able to regenerate alveolar bone tissue in vivo in an athymic rat model. Furthermore, using these data we have started a proof of principle clinical- and histological controlled study using stem cell-rich palatal tissues for improving the vertical alveolar bone augmentation in critical size defects. The initial results of the study demonstrate the feasibility of using stem cell-mediated tissue engineering to treat alveolar bone defects in humans. PMID:24921024

  13. Evaluation of Vertical Bone Regeneration Using Block and Particulate Forms of Bio-Oss Bone Graft: A Histologic Study in the Rabbit Mandible.

    PubMed

    Veis, Alexander; Dabarakis, Nikolaos; Koutrogiannis, Christos; Barlas, Irodis; Petsa, Elina; Romanos, Georgios

    2015-06-01

    The aim of the present study was to evaluate histologically vertical bone regeneration outcomes after using bovine bone graft material in block and granular forms. The buccal bony plates of the outer mandibles of 10 New Zealand rabbits received Bio-Oss blocks that were immobilized using orthopedic mini-plates, and another 10 received granular forms that were gently packed and stabilized into the custom-made perforated metallic cubes. The mean graft area (GA), new bone area (NBA), bone-to-graft contact (BGC), and maximum vertical height reached by the new bone development (MVH) were histometrically evaluated and showed no significant differences between 2 graft types. The new bone was observed mostly close to the basal bone and developed penetrating the trabecular scaffold in the form of seams that covered the intralumen surfaces of the block type graft, while in the granular graft type the new bone was observed to grow between the graft particles usually interconnecting them. Either form of Bio-Oss was capable of providing considerable vertical bone augmentation.

  14. Bone Replacement Materials and Techniques Used for Achieving Vertical Alveolar Bone Augmentation

    PubMed Central

    Sheikh, Zeeshan; Sima, Corneliu; Glogauer, Michael

    2015-01-01

    Alveolar bone augmentation in vertical dimension remains the holy grail of periodontal tissue engineering. Successful dental implant placement for restoration of edentulous sites depends on the quality and quantity of alveolar bone available in all spatial dimensions. There are several surgical techniques used alone or in combination with natural or synthetic graft materials to achieve vertical alveolar bone augmentation. While continuously improving surgical techniques combined with the use of auto- or allografts provide the most predictable clinical outcomes, their success often depends on the status of recipient tissues. The morbidity associated with donor sites for auto-grafts makes these techniques less appealing to both patients and clinicians. New developments in material sciences offer a range of synthetic replacements for natural grafts to address the shortcoming of a second surgical site and relatively high resorption rates. This narrative review focuses on existing techniques, natural tissues and synthetic biomaterials commonly used to achieve vertical bone height gain in order to successfully restore edentulous ridges with implant-supported prostheses.

  15. Comparison of Dental Panoramic Radiography and CBCT for Measuring Vertical Bone Height in Different Horizontal Locations of Posterior Mandibular Alveolar Process.

    PubMed

    Shahidi, Shoaleh; Zamiri, Barbad; Abolvardi, Masoud; Akhlaghian, Marzieh; Paknahad, Maryam

    2018-06-01

    Accurate measurement of the available bone height is an essential step in the pre-surgical phase of dental implantation. Panoramic radiography is a unique technique in the pre-surgical phase of dental implantations because of its low cost, relatively low-dose, and availability. This article aimed to assess the reliability of dental panoramic radiographs in the accurate measurement of the vertical bone height with respect to the horizontal location of the alveolar crest. 132 cone-beam computed tomography (CBCT) of the edentulous mandibular molar area and dental panoramic radiograph of 508 patients were selected. Exclusion criteria were bone abnormalities and detectable ideal information on each modality. The alveolar ridge morphology was categorized into 7 types according to the relative horizontal location of the alveolar crest to the mandibular canal based on CBCT findings. The available bone height (ABH) was defined as the distance between the upper border of the mandibular canal and alveolar crest. One oral radiologist and one oral surgeon measured the available bone height twice on each modality with a 7-dayinterval. We found a significant correlation between dental panoramic radiographs and cone-beam computed tomography values (ICC=0.992, p < 0.001). A positive correlation between the horizontal distance of the alveolar crest to the mandibular canal and measured differences between two radiographic modalities had been found (r=0.755, p < 0.001). For each single unit of increase in the horizontal distance of the alveolar crest to the mandibular canal, dental panoramic radiographs showed 0.87 unit of overestimation ( p < 0.001). Dental panoramic radiographs can be employed safely in the pre-surgical phase of dental implantation in posterior alveolus of mandible, especially in routine and simple cases.

  16. Is Bone Morphogenetic Protein-2 as Effective as Alveolar Distraction Osteogenesis for Vertical Bone Regeneration?

    PubMed

    Reuss, Jose M; Pi-Anfruns, Joan; Moy, Peter K

    2018-04-01

    The aim of this study was to assess the clinical effectiveness of alveolar distraction osteogenesis (ADO) versus recombinant human bone morphogenetic protein-2 (rh-BMP-2) for vertical ridge augmentation. Few data have been published on vertical bone regeneration using rh-BMP-2. The authors implemented a retrospective cohort study and enrolled a sample composed of patients with deficient alveolar vertical bone height. The primary predictor variable was vertical augmentation with BMP-2 and a titanium mesh or ADO. The primary outcome variable was gain in vertical bone height (millimeters) measured using computed tomography. The secondary outcome variable was postoperative complications, namely need for further grafting before or simultaneous with implant placement, soft tissue dehiscence, paresthesia, infection, implant failure, and pain. Other outcomes included implant stability at time of placement and follow-up (implant stability quotient by resonance frequency analysis), surgical time (minutes), and total treatment time until implant placement (weeks). Other study variables included location of reconstruction (maxilla or mandible). Appropriate bivariate statistics were computed and statistical significance was set a P value less than .05. The retrospective review yielded 21 patients in the BMP group and 19 in the ADO group. For the BMP-2 group, the average vertical bone gain was 2.96 ± 1.8 mm overall (maxilla, mean 3.6 ± 3.1 mm; mandible, mean 2.32 ± 1.8 mm). For the ADO group, this gain was 4 ± 1.69 mm overall (maxilla, mean 2.8 ± 1.94 mm; mandible, mean 5.2 ± 4.67 mm). For complications, group BMP showed a statistically minor tendency for more postoperative problems, such as wound dehiscence. For implant survival, group BMP showed a 92.2% survival rate versus 96.3% in group ADO at 3 to 45 months after delivery of the prosthesis (average, 22 months). The 2 techniques showed similar values in absolute vertical bone gain. Group ADO showed a slightly better outcome in outright vertical regenerative potential, albeit with a more frequent need for regrafting before and simultaneous with implant placement. Group BMP showed a lesser need for regrafting, despite having a higher postoperative complication rate. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Vertical augmentation with interpositional blocks of anorganic bovine bone vs. 7-mm-long implants in posterior mandibles: 1-year results of a randomized clinical trial.

    PubMed

    Felice, Pietro; Pellegrino, Gerardo; Checchi, Luigi; Pistilli, Roberto; Esposito, Marco

    2010-12-01

    To evaluate whether 7-mm-long implants could be an alternative to longer implants placed in vertically augmented posterior mandibles. Sixty patients with posterior mandibular edentulism with 7-8 mm bone height above the mandibular canal were randomized to either vertical augmentation with anorganic bovine bone blocks and delayed 5-month placement of ≥10 mm implants or to receive 7-mm-long implants. Four months after implant placement, provisional prostheses were delivered, replaced after 4 months, by definitive prostheses. The outcome measures were prosthesis and implant failures, any complications and peri-implant marginal bone levels. All patients were followed to 1 year after loading. One patient dropped out from the short implant group. In two augmented mandibles, there was not sufficient bone to place 10-mm-long implants possibly because the blocks had broken apart during insertion. One prosthesis could not be placed when planned in the 7 mm group vs. three prostheses in the augmented group, because of early failure of one implant in each patient. Four complications (wound dehiscence) occurred during graft healing in the augmented group vs. none in the 7 mm group. No complications occurred after implant placement. These differences were not statistically significant. One year after loading, patients of both groups lost an average of 1 mm of peri-implant bone. There no statistically significant differences in bone loss between groups. When residual bone height over the mandibular canal is between 7 and 8 mm, 7 mm short implants might be a preferable choice than vertical augmentation, reducing the chair time, expenses and morbidity. These 1-year preliminary results need to be confirmed by follow-up of at least 5 years. © 2010 John Wiley & Sons A/S.

  18. A simple, time-saving chairside device for radiographic diagnosis of vertical bone height and soft tissue thickness for implant placement--clinical report.

    PubMed

    Kharade, Pankaj; Banerjee, Ardhendu; Gupta, Tapas

    2012-01-01

    A diagnostic radiograph of the posterior regions of the jaws is mandatory if implant placement is considered at these sites. The goal is to avoid damage to important anatomical structures such as the inferior alveolar canal and maxillary sinus. Using radiographs to evaluate the remaining bone height available for implant insertion is a common procedure. Many articles have evaluated the success rates of fixed prostheses supported by osseointegrated implants, indicating high rates of success for prostheses 5-10 years in function. However, if an orthopantomogram machine is not readily available, periapical radiographs can be used for vertical bone height assessment. The familiar procedure of incorporating a metal ball of known diameter into an acrylic template is the method of choice. This is a relatively tedious and expensive procedure involving multiple steps, including impression taking, creation of a study model, and manufacture of a metal ball-bearing acrylic template. A further disadvantage for the patient is that a diagnostic radiograph can be taken only at the next appointment. This paper describes a quick and simple method to obtain a radiographic evaluation of remaining alveolar bone height and soft tissue thickness prior to implant placement with help of a metal ball device to avoid template fabrication and time consumption. Soft tissue thickness is measured nonsurgically.

  19. Acceleration of Alveolar Ridge Augmentation Using a Low Dose of Recombinant Human Bone Morphogenetic Protein-2 Loaded on a Resorbable Bioactive Ceramic.

    PubMed

    Fahmy, Rania A; Mahmoud, Naguiba; Soliman, Samia; Nouh, Samir R; Cunningham, Larry; El-Ghannam, Ahmed

    2015-12-01

    The aim of the present study was to evaluate the effect of a porous silica-calcium phosphate composite (SCPC50) loaded with and without recombinant human bone morphogenetic protein-2 (rhBMP-2) on alveolar ridge augmentation in saddle-type defects. Micro-granules of SCPC50 resorbable bioactive ceramic were coated with rhBMP-2 10 mg and then implanted into a saddle-type defect (12 × 7 mm) in a dog mandible and covered with a collagen membrane. Control groups included defects grafted with SCPC50 granules without rhBMP-2 and un-grafted defects. Bone healing was evaluated at 8 and 16 weeks using histologic and histomorphometric techniques. The increase in bone height and total defect fill were assessed for each specimen using the ImageJ 1.46 program. The release kinetics of rhBMP-2 was determined in vitro. The height of the bone in the grafted defects and the total defect fill were statistically analyzed. SCPC50 enhanced alveolar ridge augmentation as indicated by the increased vertical bone height, bone surface area, and bone volume after 16 weeks. SCPC50-rhBMP-2 provided a sustained release profile of a low effective dose (BMP-2 4.6 ± 1.34 pg/mL per hour) during the 1- to 21-day period. The slow rate of release of rhBMP-2 from SCPC50 accelerated synchronized complete bone regeneration and graft material resorption in 8 weeks. Successful rapid reconstruction of the alveolar ridge by SCPC50 and SCPC50-rhBMP-2 occurred without any adverse excessive bone formation, inflammation, or fluid-filled voids. Results of this study suggest that SCPC50 is an effective graft material to preserve the alveolar ridge after tooth extraction. Coating SCPC50-rhBMP-2 further accelerated bone regeneration and a considerable increase in vertical bone height. These findings make SCPC50 the primary choice as a carrier for rhBMP-2. SCPC50-rhBMP-2 can serve as an alternative to autologous bone grafting. Published by Elsevier Inc.

  20. Response of ramus following vertical lengthening with distraction osteogenesis.

    PubMed

    Tuzuner-Oncul, Aysegul Mine; Kisnisci, Reha S

    2011-09-01

    Vertical lengthening of the mandibular ramus is considered to be one of the least stable surgical procedures in the management of musculoskeletal maxillofacial deformities. The aim of this study was to evaluate the response of the mandibular ramus following vertical lengthening by means of distraction osteogenesis. This study included eight non-syndromic adult patients with temporomandibular joint ankylosis. The vertical height deficiency of the mandibular ramus and the ramus/condyle unit on the affected side were simultaneously reconstructed by transportation of a bone segment using distraction osteogenesis following gap arthroplasty. Lateral and posteroanterior (PA) cephalograms taken postoperatively before active distraction, at the completion of distraction and 6, 12, 24 months after distraction, were compared to evaluate the changes of the ramus height. In all cases the vertical ramus and ramus/condyle unit height loss were successfully reconstructed by distraction osteogenesis. There was no relapse in the amount of height gained by distraction osteogenesis at the 24 months follow-up review (p>0.05). Acute one stage vertical lengthening of the mandibular ramus is considered to be one of the least stable musculoskeletal procedures with relapse being a significant adverse outcome. In this clinical study gradual vertical lengthening of the ramus through ramus/condyle unit distraction osteogenesis has maintained the initial vertical ramus height gained for 24 months. Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Comparison of Dental Panoramic Radiography and CBCT for Measuring Vertical Bone Height in Different Horizontal Locations of Posterior Mandibular Alveolar Process

    PubMed Central

    Shahidi, Shoaleh; Zamiri, Barbad; Abolvardi, Masoud; Akhlaghian, Marzieh; Paknahad, Maryam

    2018-01-01

    Statement of the Problem: Accurate measurement of the available bone height is an essential step in the pre-surgical phase of dental implantation. Panoramic radiography is a unique technique in the pre-surgical phase of dental implantations because of its low cost, relatively low-dose, and availability. Purpose: This article aimed to assess the reliability of dental panoramic radiographs in the accurate measurement of the vertical bone height with respect to the horizontal location of the alveolar crest. Materials and Method: 132 cone-beam computed tomography (CBCT) of the edentulous mandibular molar area and dental panoramic radiograph of 508 patients were selected. Exclusion criteria were bone abnormalities and detectable ideal information on each modality. The alveolar ridge morphology was categorized into 7 types according to the relative horizontal location of the alveolar crest to the mandibular canal based on CBCT findings. The available bone height (ABH) was defined as the distance between the upper border of the mandibular canal and alveolar crest. One oral radiologist and one oral surgeon measured the available bone height twice on each modality with a 7-dayinterval. Results: We found a significant correlation between dental panoramic radiographs and cone-beam computed tomography values (ICC=0.992, p< 0.001). A positive correlation between the horizontal distance of the alveolar crest to the mandibular canal and measured differences between two radiographic modalities had been found (r=0.755, p< 0.001). For each single unit of increase in the horizontal distance of the alveolar crest to the mandibular canal, dental panoramic radiographs showed 0.87 unit of overestimation (p< 0.001). Conclusion: Dental panoramic radiographs can be employed safely in the pre-surgical phase of dental implantation in posterior alveolus of mandible, especially in routine and simple cases. PMID:29854881

  2. Novel expandable short dental implants in situations with reduced vertical bone height-technical note and first results.

    PubMed

    Reich, Waldemar; Schweyen, Ramona; Heinzelmann, Christian; Hey, Jeremias; Al-Nawas, Bilal; Eckert, Alexander Walter

    2017-10-30

    Short implants often have the disadvantage of reduced primary stability. The present study was conducted to evaluate the feasibility and safety of a new expandable short dental implant system intended to increase primary stability. As a "proof of concept", a prospective clinical cohort study was designed to investigate intraoperative handling, primary and secondary implant stability (resonance frequency analysis), crestal bone changes, implant survival and implant success, of an innovative short expandable screw implant. From 2014 until 2015, 9 patients (7-9-mm vertical bone height) with 30 implants (length 5-7 mm, diameter 3.75-4.1 mm) were recruited consecutively. All 30 implants in the 9 patients (age 44 to 80 years) could be inserted and expanded without intraoperative problems. Over the 3-year follow-up period, the implant success rate was 28/30 (93.3%). The mean implant stability quotients (ISQ) were as follows: primary stability, 69.7 ± 10.3 ISQ units, and secondary stability, 69.8 ± 10.2 ISQ units (p = 0.780), both without significant differences between the maxilla and mandible (p ≥ 0.780). The mean crestal bone changes after loading were (each measured from the baseline) as follows: in the first year, 1.0 ± 0.9 mm in the maxilla and 0.7 ± 0.4 mm in the mandible, and in the second year, 1.3 ± 0.8 mm and 1.0 ± 0.7 mm, respectively. Compared to other prospective studies, in this indication, the success rate is acceptable. Implant stability shows high initial and secondary stability values. The system might present an extension of functional rehabilitation to the group of elderly patients with limited vertical bone height. Further long-term investigations should directly compare this compressive implant with standard short implants.

  3. Influence of different abutment diameter of implants on the peri-implant stress in the crestal bone: A three-dimensional finite element analysis--In vitro study.

    PubMed

    Aradya, Anupama; Kumar, U Krishna; Chowdhary, Ramesh

    2016-01-01

    The study was designed to evaluate and compare stress distribution in transcortical section of bone with normal abutment and platform switched abutment under vertical and oblique forces in posterior mandible region. A three-dimensional finite element model was designed using ANSYS 13.0 software. The type of bone selection for the model was made of type II mandibular bone, having cortical bone thickness ranging from 0.595 mm to 1.515 mm with the crestal region measuring 1.5 mm surrounding dense trabecular bone. The implant will be modulated at 5 mm restorative platform and tapering down to 4.5 mm wide at the threads, 13 mm long with an abutment 3 mm in height. The models will be designed for two situations: (1) An implant with a 5 mm diameter abutment representing a standard platform in the posterior mandible region. (2) An implant with a 4.5 mm diameter abutment representing platform switching in the posterior mandible region. Force application was performed in both oblique and vertical conditions using 100 N as a representative masticatory force. For oblique loading, a force of 100 N was applied at 15° from the vertical axis. von Mises stress analysis was evaluated. The results of the study showed cortical stress in the conventional and platform switching model under oblique forces were 59.329 MPa and 39.952 MPa, respectively. Cortical stress in the conventional and platform switching model under vertical forces was 13.914 MPa and 12.793 MPa, respectively. Results from this study showed the platform switched abutment led to relative decrease in von Mises stress in transcortical section of bone compared to normal abutment under vertical and oblique forces in posterior mandible region.

  4. Stress Distribution Around Single Short Dental Implants: A Finite Element Study.

    PubMed

    Vidya Bhat, S; Premkumar, Priyanka; Kamalakanth Shenoy, K

    2014-12-01

    Bone height restrictions are more common in the posterior regions of the mandible, because of either bone resorption resulting from tooth loss or even anatomic limitations, such as the position of the inferior alveolar nerve. In situations where adequate bone height is not available in the posterior mandible region, smaller lengths of implants may have to be used but it has been reported that the use of long implants (length ≥10 mm) is a positive factor in osseointegration and authors have reported failures with short implants. Hence knowledge about the stress generated on the bone with different lengths of implants needs scientific evaluation. The purpose of this study was to compare and evaluate the influence of different lengths of implants on stress upon bone in mandibular posterior area. A 3 D finite element model was made of the posterior mandible using the details from a CT scan, using computer software (ANSYS 12). Four simulated implants with lengths 6 mm, 8 mm, 10 mm and 13 mm were placed in the centre of the bone. A static vertical force of 250 N and a static horizontal force of 100 N were applied. The stress generated in the cortical and cancellous bone around the implant were recorded and evaluated with the help of ANSYS. In this study, Von Mises stress on a 6 mm implant under a static vertical load of 250 N appeared to be almost in the same range of 8 and 10 mm implant which were more as compared to 13 mm implant. Von Mises stress on a 6mm implant under a static horizontal load of 100 N appeared to be less when compared to 8, 10 and 13 mm implants. From the results obtained it may be inferred that under static horizontal loading conditions, shorter implants receive lesser load and thus may tend to transfer more stresses to the surrounding bone. While under static vertical loading the shorter implants bear more loads and comparatively transmit lesser load to the surrounding bone.

  5. Accuracy of vertical height measurements on direct digital panoramic radiographs using posterior mandibular implants and metal balls as reference objects.

    PubMed

    Vazquez, L; Nizamaldin, Y; Combescure, C; Nedir, R; Bischof, M; Dohan Ehrenfest, D M; Carrel, J-P; Belser, U C

    2013-01-01

    Conventional panoramic radiography, a widely used radiographic examination tool in implant treatment planning, allows evaluation of the available bone height before inserting posterior mandibular implants. Image distortion and vertical magnification due to projection geometry is well described for rotational panoramic radiographs. To assess the accuracy of vertical height measurements on direct digital panoramic radiographs, implants and metal balls positioned in the posterior mandible were used as radio-opaque reference objects. The reproducibility of the measuring method was assessed by the inter- and intraobserver agreements. Direct digital panoramic radiographs, performed using a Kodak 8000C (Eastman Kodak Company, Rochester, NY), of 17 partially edentulous patients (10 females, 7 males, mean age 65 years) were selected from an X-ray database gathered during routine clinical evaluation of implant sites. Proprietary software and a mouse-driven calliper were used to measure the radiological length of 25 implants and 18 metal reference balls, positioned in mandibular posterior segments. The distortion ratio (DR) was calculated by dividing the radiological implant length by the implant's real length and the radiological ball height by the ball's real height. Mean vertical DR was 0.99 for implants and 0.97 for balls, and was unrelated to mandibular sites, side, age, gender or observer. Inter- and intraobserver agreements were acceptable for both reference objects. Vertical measurements had acceptable accuracy and reproducibility when a software-based calibrated measurement tool was used, confirming that digital panoramic radiography can be reliably utilized to determine the pre-operative implant length in premolar and molar mandibular segments.

  6. Paramedian vertical palatal bone height for mini-implant insertion: a systematic review.

    PubMed

    Winsauer, H; Vlachojannis, C; Bumann, A; Vlachojannis, J; Chrubasik, S

    2014-10-01

    Paramedian insertion of orthodontic mini-implants is increasingly used to anchor molar distalizers. The aim of this review was to systematically examine the available measurements of vertical palatal bone height (VBH). PUBMED, MEDLINE and the Cochrane Controlled Trials Register were searched using specific search terms. Hand searches of bibliographies of articles were also performed to identify studies measuring VBH or bone thickness in the human palate. Sixteen studies were included, arising from 19 published articles. Repeat presentations were excluded. Ten of the 11 computed tomogram (CT)-based studies presented data from 956 orthodontic patients on average VBH and its variation at a range of palatal sites. Individual data were not available, and pooling of data was not feasible because of heterogeneity of subjects, different measurement sites, different CT methods and their associated software. The compilation of data did indicate that the region 3-4mm behind the incisive foramen and 3-9mm lateral to the midpalatal suture should normally provide sufficient VBH to anchor molar distalizers. The risks of unwanted effects during distalization should be small, but the limitations listed above and the small numbers of studies available impair the precision of the estimates and do not allow the results to be generalized. Paramedian anchorage in the anterior palate can be recommended for molar distalization but, given the great inter-individual variability of the palatal bone height, it must be preceded by reliable CT-based imaging in patients identified by routine investigations as being at risk. © The Author 2012. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  7. Damping ratio analysis of tooth stability under various simulated degrees of vertical alveolar bone loss and different root types.

    PubMed

    Ho, Kuo-Ning; Lee, Sheng-Yang; Huang, Haw-Ming

    2017-08-03

    The purpose of this study was to evaluate the feasibility of using damping ratio (DR) analysis combined with resonance frequency (RF) and periotest (PTV) analyses to provide additional information about natural tooth stability under various simulated degrees of alveolar vertical bone loss and various root types. Three experimental tooth models, including upper central incisor, upper first premolar, and upper first molar were fabricated using Ti6Al4V alloy. In the tooth models, the periodontal ligament and alveolar bone were simulated using a soft lining material and gypsum, respectively. Various degrees of vertical bone loss were simulated by decreasing the surrounding bone level apically from the cementoenamel junction in 2-mm steps incrementally downward for 10 mm. A commercially available RF analyzer was used to measure the RF and DR of impulse-forced vibrations on the tooth models. The results showed that DRs increased as alveolar vertical bone height decreased and had high coefficients of determination in the linear regression analysis. The damping ratio of the central incisor model without a simulated periodontal ligament were 11.95 ± 1.92 and 27.50 ± 0.67% respectively when their bone levels were set at 2 and 10 mm apically from the cementoenamel junction. These values significantly changed to 28.85 ± 2.54% (p = 0.000) and 51.25 ± 4.78% (p = 0.003) when the tooth model was covered with simulated periodontal ligament. Moreover, teeth with different root types showed different DR and RF patterns. Teeth with multiple roots had lower DRs than teeth with single roots. Damping ratio analysis combined with PTV and RF analysis provides more useful information on the assessment of changes in vertical alveolar bone loss than PTV or RF analysis alone.

  8. Profile changes after conventional and chin shield genioplasty

    PubMed Central

    Singh, Stuti; Mehrotra, Divya; Mohammad, S.

    2014-01-01

    Introduction The aim of this study was to compare the profile changes after conventional and chin shield genioplasty. Material and method 20 patients with retruded chin were randomly allocated to two different groups. The experimental group had chin shield osteotomy with interposition of hydroxyapatite collagen graft soaked in platelet rich plasma, while the controls had a conventional genioplasty. The outcome variables evaluated were lip seal, chin thickness, mandibular base length, SNB, labiomental angle, anterior lower facial height, transverse chin shift, and complications. Results There was an increase in chin thickness among all, but a significant increase in anterior lower facial height was seen in the experimental group only. There was no statistically significant difference in satisfaction score in both groups. Conclusion Chin shield genioplasty provides horizontal as well as vertical lengthening of chin without deepening of the mentolabial fold. Hydroxyapatite collagen bone graft and platelet rich plasma promote healing, induce bone formation and reduce bone resorption. PMID:25737921

  9. Profile changes after conventional and chin shield genioplasty.

    PubMed

    Singh, Stuti; Mehrotra, Divya; Mohammad, S

    2014-01-01

    The aim of this study was to compare the profile changes after conventional and chin shield genioplasty. 20 patients with retruded chin were randomly allocated to two different groups. The experimental group had chin shield osteotomy with interposition of hydroxyapatite collagen graft soaked in platelet rich plasma, while the controls had a conventional genioplasty. The outcome variables evaluated were lip seal, chin thickness, mandibular base length, SNB, labiomental angle, anterior lower facial height, transverse chin shift, and complications. There was an increase in chin thickness among all, but a significant increase in anterior lower facial height was seen in the experimental group only. There was no statistically significant difference in satisfaction score in both groups. Chin shield genioplasty provides horizontal as well as vertical lengthening of chin without deepening of the mentolabial fold. Hydroxyapatite collagen bone graft and platelet rich plasma promote healing, induce bone formation and reduce bone resorption.

  10. Effects of Recombinant Human Bone Morphogenetic Protein-2 on Vertical Bone Augmentation in a Canine Model.

    PubMed

    Hsu, Yung-Ting; Al-Hezaimi, Khalid; Galindo-Moreno, Pablo; O'Valle, Francisco; Al-Rasheed, Abdulaziz; Wang, Hom-Lay

    2017-09-01

    Vertical bone augmentation (VBA) remains unpredictable and challenging for most clinicians. This study aims to compare hard tissue outcomes of VBA, with and without recombinant human bone morphogenetic protein (rhBMP)-2, under space-making titanium mesh in a canine model. Eleven male beagle dogs were used in the study. Experimental ridge defects were created to form atrophic ridges. VBA was performed via guided bone regeneration using titanium mesh and allografts. In experimental hemimandibles, rhBMP-2/absorbable collagen sponge was well mixed with allografts prior to procedures, whereas a control buffer was applied within controls. Dogs were euthanized after a 4-month healing period. Clinical and radiographic examinations were performed to assess ridge dimensional changes. In addition, specimens were used for microcomputed tomography (micro-CT) assessment and histologic analysis. Membrane exposure was found on five of 11 (45.5%) rhBMP-2-treated sites, whereas it was found on nine of 11 (81.8%) non-rhBMP-2-treated sites. Within 4 months of healing, rhBMP-2-treated sites showed better radiographic bone density, greater defect fill, and significantly more bone gain in ridge height (P <0.05) than controls. Experimental hemimandibles exhibited lower rates of membrane exposure and a noteworthy, ectopic bone formation above the mesh in 72% of sites. Results from micro-CT also suggested a trend of less vertical bone gain and bone mineral density in controls (P >0.05). Under light microscope, predominant lamellar patterns were found in the specimen obtained from rhBMP-2 sites. With inherent limitations of the canine model and the concern of such a demanding surgical technique, current findings suggest that the presence of rhBMP-2 in a composite graft allows an increase of vertical gain, with formation of ectopic bone over the titanium mesh in comparison with non-rhBMP-2 sites.

  11. A computer-guided bone block harvesting procedure: a proof-of-principle case report and technical notes.

    PubMed

    De Stavola, Luca; Fincato, Andrea; Albiero, Alberto Maria

    2015-01-01

    During autogenous mandibular bone harvesting, there is a risk of damage to anatomical structures, as the surgeon has no three-dimensional control of the osteotomy planes. The aim of this proof-of-principle case report is to describe a procedure for harvesting a mandibular bone block that applies a computer-guided surgery concept. A partially dentate patient who presented with two vertical defects (one in the maxilla and one in the mandible) was selected for an autogenous mandibular bone block graft. The bone block was planned using a computer-aided design process, with ideal bone osteotomy planes defined beforehand to prevent damage to anatomical structures (nerves, dental roots, etc) and to generate a surgical guide, which defined the working directions in three dimensions for the bone-cutting instrument. Bone block dimensions were planned so that both defects could be repaired. The projected bone block was 37.5 mm in length, 10 mm in height, and 5.7 mm in thickness, and it was grafted in two vertical bone augmentations: an 8 × 21-mm mandibular defect and a 6.5 × 18-mm defect in the maxilla. Supraimposition of the preoperative and postoperative computed tomographic images revealed a procedure accuracy of 0.25 mm. This computer-guided bone harvesting technique enables clinicians to obtain sufficient autogenous bone to manage multiple defects safely.

  12. Localized ridge defect augmentation using human pericardium membrane and demineralized bone matrix.

    PubMed

    Vidyadharan, Arun Kumar; Ravindran, Anjana

    2014-01-01

    Patient wanted to restore her lost teeth with implants in the lower left first molar and second premolar region. Cone beam computerized tomography (CBCT) revealed inadequate bone width and height around future implant sites. The extraction socket of second premolar area revealed inadequate socket healing with sparse bone fill after 4 months of extraction. To evaluate the clinical feasibility of using a collagen physical resorbable barrier made of human pericardium (HP) to augment localized alveolar ridge defects for the subsequent placement of dental implants. Ridge augmentation was done in the compromised area using Puros® demineralized bone matrix (DBM) Putty with chips and an HP allograft membrane. Horizontal (width) and vertical hard tissue measurements with CBCT were recorded on the day of ridge augmentation surgery, 4 month and 7 months follow-up. Intra oral periapical taken 1 year after implant installation showed minimal crestal bone loss. Bone volume achieved through guided bone regeneration was a gain of 4.8 mm horizontally (width) and 6.8 mm vertically in the deficient ridge within a period of 7 months following the procedure. The results suggested that HP Allograft membrane may be a suitable component for augmentation of localized alveolar ridge defects in conjunction with DBM with bone chips.

  13. Periodontal Therapy in Dogs Using Bone Augmentation Products Marketed for Veterinary Use.

    PubMed

    Angel, Molly

    Periodontal disease is extremely common in companion animal practice. Patients presenting for a routine oral examination and prophylaxis may be found to have extensive periodontal disease and attachment loss. Vertical bone loss is a known sequela to periodontal disease and commonly involves the distal root of the mandibular first molar. This case report outlines two dogs presenting for oral examination and prophylaxis with general anesthesia. Both patients did not have any clinical symptoms of periodontal disease other than halitosis. Both patients were diagnosed with three-walled vertical bone loss defects of one or both mandibular first molars utilizing dental radiography as well as periodontal probing, measuring, and direct visual inspection. These defects were consistent with periodontal disease index stage 4 (>50% attachment loss). The lesions were treated with appropriate root planing and debridement. Bone augmentation products readily available and marketed for veterinary use were then utilized to fill the defects to promote both the re-establishment of normal alveolar bone height and periodontal ligament reattachment to the treated surface. Follow-up assessment and owner dedication is critical to treatment outcome. Both patients' 6 mo follow-up examinations radiographically indicated bone repair and replacement with visible periodontal ligament space.

  14. Biomechanical influence of crown-to-implant ratio on stress distribution over internal hexagon short implant: 3-D finite element analysis with statistical test.

    PubMed

    Ramos Verri, Fellippo; Santiago Junior, Joel Ferreira; de Faria Almeida, Daniel Augusto; de Oliveira, Guilherme Bérgamo Brandão; de Souza Batista, Victor Eduardo; Marques Honório, Heitor; Noritomi, Pedro Yoshito; Pellizzer, Eduardo Piza

    2015-01-02

    The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p<0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p>0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p<0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p<0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Management of localized advance loss of periodontal support associated Grade II furcation and intrabony defect in chronic periodontitis patient through amalgamation of platelet-rich fibrin and hydroxyapatite bioactive glass composite granules.

    PubMed

    Salaria, Sanjeev Kumar; Ghuman, Simrat Kaur; Kumar, Saurabh; Sharma, Garima

    2016-01-01

    Periodontal disease is infectious, complex, multifactorial, chronic inflammatory disease of supporting periodontal tissues that not only alters the bone morphology but also leads to the reduction in bone height. Different types of bony deformities such as horizontal, vertical, craters, and furcation result from periodontal disease, but vertical and Grade II furcation defects are more amenable to regenerative periodontal therapy. The present case report describes the current concept of periodontal diagnosis and the clinical radiographical efficiency of platelet-rich fibrin and hydroxyapatite bioactive glass composite granules graft combination in the management of localized advance osseous defects with respect to tooth number 36 in chronic periodontitis patient at 1 year postoperatively.

  16. Five years follow-up of implant-prosthetic rehabilitation on a patient after mandibular ameloblastoma removal and ridge reconstruction by fibula graft and bone distraction

    PubMed Central

    Oteri, Giacomo; Ponte, Francesco Saverio De; Pisano, Michele; Cicciù, Marco

    2012-01-01

    This case report presents a combination of surgical and prosthetic solutions applied to a case of oral implant rehabilitation in post-oncologic reconstructed mandible. Bone resection due to surgical treatment of large mandibular neoplasm can cause long-span defects. Currently, mandibular fibula free flap graft is widely considered as a reliable technique for restoring this kind of defect. It restores the continuity of removed segment and re-establishes the contour of the lower jaw. However, the limited height of grafted fibula does not allow the insertion of regular length implants, therefore favouring vertical distraction osteogenesis as an important treatment choice. This report presents a patient affected by extensive mandibular ameloblastoma who underwent surgical reconstruction by fibula free flap because of partial mandibular resection. Guided distraction osteoneogenesis technique was applied to grafted bone, in order to obtain adequate bone height and to realize a prosthetically guided placement of 8 fixtures. After osseointegration, the patient was rehabilitated with a full arch, screw-retained prosthetic restoration. At five-years follow up, excellent integration of grafted tissue, steady levels of bone around the fixtures and healthy peri-implant tissues were reported. PMID:22623943

  17. Alveolar Ridge Split Technique Using Piezosurgery with Specially Designed Tips

    PubMed Central

    Moro, Alessandro; Foresta, Enrico; Falchi, Marco; De Angelis, Paolo; D'Amato, Giuseppe; Pelo, Sandro

    2017-01-01

    The treatment of patients with atrophic ridge who need prosthetic rehabilitation is a common problem in oral and maxillofacial surgery. Among the various techniques introduced for the expansion of alveolar ridges with a horizontal bone deficit is the alveolar ridge split technique. The aim of this article is to give a description of some new tips that have been specifically designed for the treatment of atrophic ridges with transversal bone deficit. A two-step piezosurgical split technique is also described, based on specific osteotomies of the vestibular cortex and the use of a mandibular ramus graft as interpositional graft. A total of 15 patients were treated with the proposed new tips by our department. All the expanded areas were successful in providing an adequate width and height to insert implants according to the prosthetic plan and the proposed tips allowed obtaining the most from the alveolar ridge split technique and piezosurgery. These tips have made alveolar ridge split technique simple, safe, and effective for the treatment of horizontal and vertical bone defects. Furthermore the proposed piezosurgical split technique allows obtaining horizontal and vertical bone augmentation. PMID:28246596

  18. Alveolar Ridge Split Technique Using Piezosurgery with Specially Designed Tips.

    PubMed

    Moro, Alessandro; Gasparini, Giulio; Foresta, Enrico; Saponaro, Gianmarco; Falchi, Marco; Cardarelli, Lorenzo; De Angelis, Paolo; Forcione, Mario; Garagiola, Umberto; D'Amato, Giuseppe; Pelo, Sandro

    2017-01-01

    The treatment of patients with atrophic ridge who need prosthetic rehabilitation is a common problem in oral and maxillofacial surgery. Among the various techniques introduced for the expansion of alveolar ridges with a horizontal bone deficit is the alveolar ridge split technique. The aim of this article is to give a description of some new tips that have been specifically designed for the treatment of atrophic ridges with transversal bone deficit. A two-step piezosurgical split technique is also described, based on specific osteotomies of the vestibular cortex and the use of a mandibular ramus graft as interpositional graft. A total of 15 patients were treated with the proposed new tips by our department. All the expanded areas were successful in providing an adequate width and height to insert implants according to the prosthetic plan and the proposed tips allowed obtaining the most from the alveolar ridge split technique and piezosurgery. These tips have made alveolar ridge split technique simple, safe, and effective for the treatment of horizontal and vertical bone defects. Furthermore the proposed piezosurgical split technique allows obtaining horizontal and vertical bone augmentation.

  19. A novel type of dental tube implant for areas with limited bone height. Clinical and radiographic data from three patients with 5-year follow-up.

    PubMed

    Lundgren, Dan; Slotte, Christer; Gröndahl, Kerstin

    2013-08-01

    Alternative implant designs may reduce the need for complicated and costly bone augmentation procedures in situations with limited bone height. Wide dental tube implants have been manufactured and tested in three patients and followed for 5 years to evaluate if such implants are capable to support fixed prosthetic constructions with good prognosis in areas with limited bone height. Four machined-tube implants with a height of 6 mm, an outer diameter of 7.4 mm, and an inner diameter of 6.0 mm were placed in three patients. After a healing period of 3 months, ceramometal suprastructures were constructed to supply the implants. Annual clinical and radiographical follow-ups were done up to 5 years. At the 5-year follow-up, all three patients were examined with a cone beam computed tomography technique. All implants and the suprastructures were clinically stable after 5 years. In one patient, vertical bone loss and a 6-mm deep pocket appeared after 1 year. The pocket has remained throughout the observation period and has been regularly debrided and kept it free from clinical signs of inflammation. In the other two patients, the soft tissue surrounding the implants was in good health with no or only slight inflammation throughout all observations. Pocket probing revealed no or slight bleeding and pocket depths amounting to less than 3 mm. It was shown that this new type of implant will function excellent during follow-up times of several years. Further studies should be done to explore in more detail indications for such implants. © 2011 Wiley Periodicals, Inc.

  20. T-bone plastique for treatment of brachy-turricephaly.

    PubMed

    Donauer, E; Bernardy, M; Neuenfeldt, D

    1993-01-01

    The "T-Bone Plastique", which is presented in this paper, allows a surgical correction even of extreme cases of brachy-turricephaly together with malformations of the occipital region in one operative session. Brachy-turricephaly is characterized by abnormal vertical height of the skull and a shortening of its anterior-posterior length, frequently combined with malformations of the occipital region. Resection of the prematurely closed coronal suture, bi-parietal trepanations with 90 degrees rotation and side-exchange of the parietal bone flaps, double transverse trepanation of the occipital bone and outward bending and shifting of the bone fragments enable a bony remodeling and normalization of the deformed skull. Using this operative technique in three children we achieved a significant improvement of the skull form with an aesthetically pleasing result, without any neurologic sequelae and with normal development of the children during follow-up.

  1. Implant treatment in atrophic posterior mandibles: vertical regeneration with block bone grafts versus implants with 5.5-mm intrabony length.

    PubMed

    Peñarrocha-Oltra, David; Aloy-Prósper, Amparo; Cervera-Ballester, Juan; Peñarrocha-Diago, Maria; Canullo, Luigi; Peñarrocha-Diago, Miguel

    2014-01-01

    To retrospectively compare the outcomes of implants placed in posterior mandibles vertically regenerated with onlay autogenous block bone grafts and short dental implants. Consecutive patients with vertical bone atrophy in edentulous mandibular posterior regions (7 to 8 mm of bone above the inferior alveolar nerve) were treated with either implants placed in regenerated bone using autologous block bone grafts (group 1) or short implants (with 5.5-mm intrabony length) in native bone (group 2) between 2005 and 2010 and followed for 12 months after loading. The procedure used was the established treatment protocol for this type of patient at the Oral Surgery Unit (University of Valencia, Spain) at the time of surgery. All grafts were obtained using piezosurgery. The outcomes assessed were: complications related to the procedure, implant survival, implant success, and peri-implant marginal bone loss. Statistical analysis was done using the Fisher exact test and the Mann-Whitney test. Thirty-seven patients were included, 20 (45 implants) in group 1 and 17 (35 implants) in group 2. In group 1, 13 implants were less than 10 mm long (2 were 7 mm and 11 were 8.5 mm), and 32 were 10 mm or longer; the diameter was 3.6 mm in 6 implants, 4.2 mm in 31, and 5.5 mm in 8. In group 2 all implants were 7 mm long; the diameter measured 4.2 mm in 14 implants and 5.5 mm in 21 implants. Complications related to the block bone grafting procedure were temporary hypoesthesia in one patient, wound dehiscence with graft exposure in three patients, and exposure of the osteosynthesis screw without bone graft exposure in one patient. After 12 months, implant survival rates were 95.6% in group 1 and 97.1 % in group 2; success rates were 91.1% and 97.1%, respectively. The average marginal bone loss was 0.7 ± 1.1 mm in group 1 and 0.6 ± 0.3 mm in group 2. When residual bone height over the mandibular canal is between 7 and 8 mm, short implants (with 5.5-mm intrabony length) might be a preferable treatment option over vertical augmentation, reducing chair time, expense, and morbidity.

  2. Surgiplanner: a new method for one step oral rehabilitation of severe atrophic maxilla

    PubMed Central

    BUSATO, A.; VISMARA, V.; GRECCHI, F.; GRECCHI, E.; LAURITANO, D.

    2017-01-01

    SUMMARY The implant-prosthetic rehabilitation of edentulous upper jaws has always been complex for surgeons and dentists. The lack of bone in both vertical and horizontal dimension does not allow the correct insertion of dental implants. In addition, patients with edentulous upper and lower arch have a loss of vertical dimension of the face and an aged expression. Many surgical techniques have been proposed to increase the bone volume, height and thickness, such as the Le Fort I osteotomy, the bone grafts and the placement of dental implants. Planning these surgical procedures is difficult, because it is not possible to reproduce the movements of osteotomized bone segments in three planes of space. This article describes the treatment of severe atrophy maxilla with a new approach using a new instrument named “Surgiplanner”. Surgiplanner is a method that, only using a computerized axial tomography (CAT), allows to obtain a totally predetermined therapeutic result from both an aesthetic and functional point of view, with surgery of severe resorbed jaws. Surgiplanner allows repositioning of segment of the skeleton of the patient’s face in a predetermined and controlled way for the best implant-supported oral rehabilitation. PMID:29285336

  3. Surgiplanner: a new method for one step oral rehabilitation of severe atrophic maxilla.

    PubMed

    Busato, A; Vismara, V; Grecchi, F; Grecchi, E; Lauritano, D

    2017-01-01

    The implant-prosthetic rehabilitation of edentulous upper jaws has always been complex for surgeons and dentists. The lack of bone in both vertical and horizontal dimension does not allow the correct insertion of dental implants. In addition, patients with edentulous upper and lower arch have a loss of vertical dimension of the face and an aged expression. Many surgical techniques have been proposed to increase the bone volume, height and thickness, such as the Le Fort I osteotomy, the bone grafts and the placement of dental implants. Planning these surgical procedures is difficult, because it is not possible to reproduce the movements of osteotomized bone segments in three planes of space. This article describes the treatment of severe atrophy maxilla with a new approach using a new instrument named "Surgiplanner". Surgiplanner is a method that, only using a computerized axial tomography (CAT), allows to obtain a totally predetermined therapeutic result from both an aesthetic and functional point of view, with surgery of severe resorbed jaws. Surgiplanner allows repositioning of segment of the skeleton of the patient's face in a predetermined and controlled way for the best implant-supported oral rehabilitation.

  4. Alveolar bone changes after asymmetric rapid maxillary expansion.

    PubMed

    Akin, Mehmet; Baka, Zeliha Muge; Ileri, Zehra; Basciftci, Faruk Ayhan

    2015-09-01

    To quantitatively evaluate the effects of asymmetric rapid maxillary expansion (ARME) on cortical bone thickness and buccal alveolar bone height (BABH), and to determine the formation of dehiscence and fenestration in the alveolar bone surrounding the posterior teeth, using cone-beam computed tomography (CBCT). The CBCT records of 23 patients with true unilateral posterior skeletal crossbite (10 boys, 14.06 ± 1.08 years old, and 13 girls, 13.64 ± 1.32 years old) who had undergone ARME were selected from our clinic archives. The bonded acrylic ARME appliance, including an occlusal stopper, was used on all patients. CBCT records had been taken before ARME (T1) and after the 3-month retention period (T2). Axial slices of the CBCT images at 3 vertical levels were used to evaluate the buccal and palatal aspects of the canines, first and second premolars, and first molars. Paired samples and independent sample t-tests were used for statistical comparison. The results suggest that buccal cortical bone thickness of the affected side was significantly more affected by the expansion than was the unaffected side (P < .05). ARME significantly reduced the BABH of the canines (P < .01) and the first and second premolars (P < .05) on the affected side. ARME also increased the incidence of dehiscence and fenestration on the affected side. ARME may quantitatively decrease buccal cortical bone thickness and height on the affected side.

  5. Interventions for Dental Implant Placement in Atrophic Edentulous Mandibles: Vertical Bone Augmentation and Alternative Treatments. A Meta-Analysis of Randomized Clinical Trials.

    PubMed

    Camps-Font, Octavi; Burgueño-Barris, Genís; Figueiredo, Rui; Jung, Ronald E; Gay-Escoda, Cosme; Valmaseda-Castellón, Eduard

    2016-12-01

    The purpose of the current study is to assess which vertical bone augmentation techniques are most effective for restoring atrophic posterior areas of the mandible with dental implants and compare these procedures with alternative treatments. Electronic literature searches in PubMed (MEDLINE), Ovid, and the Cochrane Library were conducted to identify all relevant articles published up to July 1, 2015. Eligibility was based on inclusion criteria, and quality assessments were conducted. The primary outcome variables were implant and prosthetic failure. After data extraction, meta-analyses were performed. Out of 527 potentially eligible papers, 14 randomized clinical trials were included. Out of these 14 studies, four trials assessed short implants (5 to 8 mm) as an alternative to vertical bone augmentation in sites with a residual ridge height of 5 to 8 mm. No statistically significant differences were found in implant (odds ratio [OR]: 1.02; 95% confidence interval [CI]: 0.31 to 3.31; P = 0.98; I 2 : 0%) or prosthetic failure (OR: 0.64; 95% CI: 0.21 to 1.96; P = 0.43; I 2 : 0%) after 12 months of loading. However, complications at treated sites increased with the augmentation procedures (OR: 8.33; 95% CI: 3.85 to 20.0; P <0.001; I 2 : 0%). There was no evidence of any vertical augmentation procedure being of greater benefit than any other for the primary outcomes (implant and prosthetic failure). Short implants in the posterior area of the mandible seem to be preferable to vertical augmentation procedures, which present similar implant and prosthetic failure rates but greater morbidity. All the vertical augmentation technique comparisons showed similar intergroup results.

  6. Marginal and apical bone stability after staged sinus floor augmentation using bone condensing implants with variable-thread design: a two-dimensional analysis.

    PubMed

    Younes, F; Eghbali, A; De Troyer, S; De Bruyckere, T; Cleymaet, R; Cosyn, J

    2016-09-01

    Studies on the vertical stability of augmented bone after sinus lifting differ substantially. In addition, long healing periods are usually advocated prior to implant installation. The purpose of this case series study was to evaluate the changes in bone height after sinus lifting with a bovine-derived xenograft and to evaluate the clinical outcome of bone condensing implants installed after a short healing period. Patients treated during the years 2010-2013 were re-examined using peri-apical radiographs to evaluate the changes in augmented bone height (BH) and marginal bone loss (BL). Fifty-seven of 70 eligible subjects (28 male and 29 female, mean age 56 years) attended for reassessment. Data were available for 53 sinus lifts and 105 implants installed after a mean healing period of 4.6±1.5 months. Implant survival was 99% after a mean time in function of 19±9 months. Baseline BH, BH at implant placement, and final BH were on average 3.87±1.74mm, 13.75±2.12mm, and 13.11±2.12mm, respectively (P<0.001). Mean BL was 0.51±0.65mm. Only limited resorption is to be expected after sinus lifting in the short term. A bone condensing implant can be used in the early healing phase with successful outcomes in terms of implant survival and bone adaptation. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

    PubMed

    Desai, Shrikar R; Singh, Rika; Karthikeyan, I

    2013-09-01

    The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  8. Comparative evaluation of the effectiveness of the implantation in the lateral part of the mandible between short tissue level (TE) and bone level (BL) implant systems.

    PubMed

    Hadzik, Jakub; Botzenhart, Ute; Krawiec, Maciej; Gedrange, Tomasz; Heinemann, Friedhelm; Vegh, Andras; Dominiak, Marzena

    2017-09-01

    Short dental implants can be an alternative method of treatment to a vertical bone augmentation procedure at sites of reduced alveolar height. However, for successful treatment, an implant system that causes a minimal marginal bone loss (MBL) should be taken into consideration. The aim of the study has been to evaluate implantation effectiveness for bone level and tissue level short implants provided in lateral aspects of partially edentulous mandible and limited alveolar ridge height. The MBL and primary as well as secondary implant stability were determined in the study. Patients were randomly divided into two groups according to the method of treatment provided. Sixteen short Bone Level Implants (OsseoSpeed TX, Astra tech) and 16 short Tissue Level Implants (RN SLActive ® , Straumann) were successfully placed in the edentulous part of the mandible. The determination of the marginal bone level was based on radiographic evaluation after 12 and 36 weeks. Implant stability was measured immediately after insertion and after 12 weeks. The marginal bone level of Bone Level Implants was significantly lower compared to Tissue Level Implants. Furthermore, the Bone Level Implants had greater primary and secondary stability in comparison with Tissue Level Implants (Primary: 77.8 ISQ versus 66.5 ISQ; Secondary: 78.9 ISQ versus 73.9 ISQ, respectively). Since short Bone Level Implants showed a significantly decreased MBL 12 and 36 weeks after implantation as well as better results for the primary stability compared to Tissue Level Implants, they should preferentially be used for this mentioned indication. Copyright © 2017 Elsevier GmbH. All rights reserved.

  9. Identification of predisposing factors for osteonecrosis of the jaw after marginal mandibulectomy in the surgical management of oral squamous cell carcinoma.

    PubMed

    Ito, Ran; Huang, Jung-Ju; Hsieh, Wei-Chuan; Kao, Huang-Kai; Lao, William Wei-Kai; Fang, Ku-Hao; Huang, Yenlin; Chang, Yu-Liang; Cheng, Ming-Huei; Chang, Kai-Ping

    2018-03-01

    The aim of this study is to evaluate osteonecrosis of the jaw (ONJ) with the extent of marginal mandibulectomy. Between January 2006 and December 2012, 3087 patients undergoing ablative resection were consecutively enrolled. Among them, 345 cases undergoing marginal mandibulectomy were retrospectively reviewed. The occurrence of ONJ was 5.51% and associated with body mass index, overall stage, diabetes, concomitant mandibulotomy, and radiotherapy (P = 0.023, 0.033, 0.009, 0.016, and 0.006, respectively). As for bone parameters based on radiological measurements after marginal mandibulectomy, resected bone height, remaining bone height to original bone height ratio, and resected bone height to original bone height ratio were associated with ONJ. In multivariate logistic analyses, concomitant mandibulotomy, radiotherapy, diabetes, resected bone height of >14.5 mm, resected bone height to original bone height ratio of >49.5%, and remaining bone height to original bone height ratio of <53.5% indicated higher risks for ONJ (adjusted HR: 4.345, 4.152, 4.079, 3.402, 3.541, and 3.211; P = 0.018, 0.013, 0.009, 0.021, 0.018, and 0.043, respectively). This study demonstrated the predisposing factors and parameters associated with ONJ with marginal mandibulectomy; more caution is necessitated in performing marginal mandibulectomy in patients with multiple risks to prevent ONJ. © 2017 Wiley Periodicals, Inc.

  10. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla

    PubMed Central

    Desai, Shrikar R.; Singh, Rika; Karthikeyan, I.

    2013-01-01

    Aim: The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. Materials and Methods: A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm–diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. Results: The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Conclusion: Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results. PMID:24174759

  11. Influence of Chromium-Cobalt-Molybdenum Alloy (ASTM F75) on Bone Ingrowth in an Experimental Animal Model.

    PubMed

    Zuchuat, Jésica; Berli, Marcelo; Maldonado, Ysaí; Decco, Oscar

    2017-12-26

    Cr-Co-Mo (ASTM F75) alloy has been used in the medical environment, but its use as a rigid barrier membrane for supporting bone augmentation therapies has not been extensively investigated. In the present study, Cr-Co-Mo membranes of different heights were placed in New Zealand white, male rabbit tibiae to assess the quality and volume of new bone formation, without the use of additional factors. Animals were euthanized at 20, 30, 40, and 60 days. Bone formation was observed in all of the cases, although the tibiae implanted with the standard membranes reached an augmentation of bone volume that agreed with the density values over the timecourse. In all cases, plasmatic exudate was found under the membrane and in contact with the new bone. Histological analysis indicated the presence of a large number of chondroblasts adjacent to the inner membrane surface in the first stages, and osteoblasts and osteocytes were observed under them. The bone formation was appositional. The Cr-Co-Mo alloy provides a scaffold with an adequate microenvironment for vertical bone volume augmentation, and the physical dimensions and disposition of the membrane itself influence the new bone formation.

  12. Influence of Chromium-Cobalt-Molybdenum Alloy (ASTM F75) on Bone Ingrowth in an Experimental Animal Model

    PubMed Central

    Zuchuat, Jésica; Berli, Marcelo; Maldonado, Ysaí; Decco, Oscar

    2017-01-01

    Cr-Co-Mo (ASTM F75) alloy has been used in the medical environment, but its use as a rigid barrier membrane for supporting bone augmentation therapies has not been extensively investigated. In the present study, Cr-Co-Mo membranes of different heights were placed in New Zealand white, male rabbit tibiae to assess the quality and volume of new bone formation, without the use of additional factors. Animals were euthanized at 20, 30, 40, and 60 days. Bone formation was observed in all of the cases, although the tibiae implanted with the standard membranes reached an augmentation of bone volume that agreed with the density values over the timecourse. In all cases, plasmatic exudate was found under the membrane and in contact with the new bone. Histological analysis indicated the presence of a large number of chondroblasts adjacent to the inner membrane surface in the first stages, and osteoblasts and osteocytes were observed under them. The bone formation was appositional. The Cr-Co-Mo alloy provides a scaffold with an adequate microenvironment for vertical bone volume augmentation, and the physical dimensions and disposition of the membrane itself influence the new bone formation. PMID:29278372

  13. Rehabilitation of postrior atrophic edentulous jaws: prostheses supported by 5 mm short implants or by longer implants in augmented bone? One-year results from a pilot randomised clinical trial.

    PubMed

    Esposito, Marco; Pellegrino, Gerardo; Pistilli, Roberto; Felice, Pietro

    2011-01-01

    To evaluate whether 5 mm short dental implants could be an alternative to augmentation with anorganic bovine bone and placement of at least 10 mm long implants in posterior atrophic jaws. Fifteen patients with bilateral atrophic mandibles (5-7 mm bone height above the mandibular canal), and 15 patients with bilateral atrophic maxillae (4-6 mm bone height below the maxillary sinus) and bone thickness of at least 8 mm, were randomised according to a splitmouth design to receive one to three 5 mm short implants or at least 10 mm long implants in augmented bone. Mandibles were vertically augmented with interpositional bone blocks and maxillary sinuses with particulated bone via a lateral window. Implants were placed after 4 months, submerged and loaded, after 4 months, with provisional prostheses. Four months later, definitive provisionally cemented prostheses were delivered. Outcome measures were: prosthesis and implant failures, any complication and peri-implant marginal bone level changes. In 5 augmented mandibles, the planned 10 mm long implants could not be placed and shorter implants (7 and 8.5 mm) had to be used instead. One year after loading no patient dropped out. Two long (8.5 mm in the mandible and 13 mm in the maxilla) implants and one 5 mm short maxillary implant failed. There were no statistically significant differences in failures or complications. Patients with short implants lost on average 1 mm of peri-implant bone and patients with longer implants lost 1.2 mm. This difference was statistically significant. This pilot study suggests that 1 year after loading, 5 mm short implants achieve similar if not better results than longer implants placed in augmented bone. Short implants might be a preferable choice to bone augmentation since the treatment is faster, cheaper and associated with less morbidity, however their long-term prognosis is unknown.

  14. The three-dimensional reconstruction of the jaw with "bone slat technique" in conjunction with third molar removal.

    PubMed

    Santagata, Mario; Cecere, Atirge; Prisco, Rosario V E; Tartaro, Gianpaolo; D'Amato, Salvatore

    2017-01-01

    The purpose of this study was to report the outcome of the management of both horizontal and vertical defects of alveolar crest using the bone slat technique approach in conjunction with third molar removal prior to implant placement in the aesthetic area. We present a 20-year-old female patient who lost a maxillary lateral incisor. The objective of treatment was to replace the lateral incisor with an implant-supported crown restoration without interfering with the integrity and topography of the adjacent gingival tissues. Because the future implant site showed horizontal and vertical bone defect the Authors decided to perform bone regeneration. The need for such bone augmentation in the younger patient often coincides with the timing for third molar removal. By combining third molar extraction with bone harvest and alveolar grafting, the patient undergoes only one surgical approach. The bone height (9.5 mm) and width (5.7 mm) were measured at the point of interest (tooth 12) both before and after implant placement in the reconstructed panoramic and parasagittal views by Cone Beam Computed Tomography (CBCT) scan. The final results demonstrated an increase in length of 5 mm after bone slat technique (from 9.5 mm to 13.5 mm) and an increase in width of 1 mm (from 5.7 mm to 6.7 mm). ISQ measurements were recorded at the time of implant placement (the mean was: 68.5) and immediately after individualized screw-retained provisional crown (the mean was: 77). This technique is reliable and aesthetic and functional results appear to be stable and respect this requisite: simple and fast graft harvesting and low risk of morbidity especially in conjunction with third molar removal.

  15. The three-dimensional reconstruction of the jaw with “bone slat technique” in conjunction with third molar removal

    PubMed Central

    Santagata, Mario; Cecere, Atirge; Prisco, Rosario V.E.; Tartaro, Gianpaolo

    2017-01-01

    Summary Background The purpose of this study was to report the outcome of the management of both horizontal and vertical defects of alveolar crest using the bone slat technique approach in conjunction with third molar removal prior to implant placement in the aesthetic area. Methods We present a 20-year-old female patient who lost a maxillary lateral incisor. The objective of treatment was to replace the lateral incisor with an implant-supported crown restoration without interfering with the integrity and topography of the adjacent gingival tissues. Because the future implant site showed horizontal and vertical bone defect the Authors decided to perform bone regeneration. The need for such bone augmentation in the younger patient often coincides with the timing for third molar removal. By combining third molar extraction with bone harvest and alveolar grafting, the patient undergoes only one surgical approach. The bone height (9.5 mm) and width (5.7 mm) were measured at the point of interest (tooth 12) both before and after implant placement in the reconstructed panoramic and parasagittal views by Cone Beam Computed Tomography (CBCT) scan. Results The final results demonstrated an increase in length of 5 mm after bone slat technique (from 9.5 mm to 13.5 mm) and an increase in width of 1 mm (from 5.7 mm to 6.7 mm). ISQ measurements were recorded at the time of implant placement (the mean was: 68.5) and immediately after individualized screw-retained provisional crown (the mean was: 77). Conclusions This technique is reliable and aesthetic and functional results appear to be stable and respect this requisite: simple and fast graft harvesting and low risk of morbidity especially in conjunction with third molar removal. PMID:29682225

  16. Alveolar socket preservation with demineralised bovine bone mineral and a collagen matrix

    PubMed Central

    2017-01-01

    Purpose The aim of the present study was to evaluate the healing of post-extraction sockets following alveolar ridge preservation clinically, radiologically, and histologically. Methods Overall, 7 extraction sockets in 7 patients were grafted with demineralised bovine bone mineral and covered with a porcine-derived non-crosslinked collagen matrix (CM). Soft tissue healing was clinically evaluated on the basis of a specific healing index. Horizontal and vertical ridge dimensional changes were assessed clinically and radiographically at baseline and 6 months after implant placement. For histological and histomorphometric analysis, bone biopsies were harvested from the augmented sites during implant surgery 6 months after the socket preservation procedure. Results Clinically, healing proceeded uneventfully in all the sockets. A trend towards reduced horizontal and vertical socket dimensions was observed from baseline to the final examination. The mean width and height of resorption were 1.21 mm (P=0.005) and 0.46 mm (P=0.004), respectively. Histologically, residual xenograft particles (31.97%±3.52%) were surrounded by either newly formed bone (16.02%±7.06%) or connective tissue (50.67%±8.42%) without fibrous encapsulation. The CM underwent a physiological substitution process in favour of well-vascularised collagen-rich connective tissue. Conclusions Socket preservation using demineralised bovine bone mineral in combination with CM provided stable dimensional changes of the alveolar ridge associated with good re-epithelialisation of the soft tissues during a 6-month healing period. PMID:28861284

  17. Implant treatment planning regarding augmentation procedures: panoramic radiographs vs. cone beam computed tomography images.

    PubMed

    Dagassan-Berndt, Dorothea C; Zitzmann, Nicola U; Walter, Clemens; Schulze, Ralf K W

    2016-08-01

    To evaluate the impact of cone beam computed tomography (CBCT) imaging on treatment planning regarding augmentation procedures for implant placement. Panoramic radiographs and CBCT images of 40 patients requesting single-tooth implants in 59 sites were retrospectively analyzed by six specialists in implantology, and treatment planning was performed. Therapeutic recommendations were compared with the surgical protocol performed initially. Bone height estimation from panoramic radiographs yielded to higher measures and greater variability compared to CBCT. The suggested treatment plan for lateral and vertical augmentation procedures based on CBCT or panoramic radiographs coincided for 55-72% of the cases. A trend to a more invasive augmentation procedure was seen when planning was based on CBCT. Panoramic radiography revealed 57-63% (lateral) vs. 67% (vertical augmentation) congruent plans in agreement with surgery. Among the dissenting sites, there was a trend toward less invasive planning for lateral augmentation with panoramic radiographs, while vertical augmentation requirements were more frequently more invasive when based on CBCT. Vertical augmentation requirements can be adequately determined from panoramic radiographs. In difficult cases with a deficient lateral alveolar bone, the augmentation schedule may better be evaluated from CBCT to avoid underestimation, which occurs more frequently when based on panoramic radiographs only. However, overall, radiographic interpretation and diagnostic thinking accuracy seem to be mainly depending on the opinion of observers. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Morphologic evaluation of dentoalveolar structures of mandibular anterior teeth during augmented corticotomy-assisted decompensation.

    PubMed

    Ahn, Hyo-Won; Seo, Dong-Hwi; Kim, Seong-Hun; Park, Young-Guk; Chung, Kyu-Rhim; Nelson, Gerald

    2016-10-01

    Our aim in this study was to evaluate the effect of augmented corticotomy on the decompensation pattern of mandibular anterior teeth, alveolar bone, and surrounding periodontal tissues during presurgical orthodontic treatment. Thirty skeletal Class III adult patients were divided into 2 groups according to the application of augmented corticotomy labial to the anterior mandibular roots: experimental group (with augmented corticotomy, n = 15) and control group (without augmented corticotomy, n = 15). Lateral cephalograms and cone-beam computed tomography images were taken before orthodontic treatment and before surgery. The measurements included the inclination and position of the mandibular incisors, labial alveolar bone area, vertical alveolar bone height, root length, and alveolar bone thickness at 3 levels surrounding the mandibular central incisors, lateral incisors, and canines. The mandibular incisors were significantly proclined in both groups (P <0.001); however, the labial movement of the incisor tip was greater in the experimental group (P <0.05). Significant vertical alveolar bone loss was observed only in the control group (P <0.001). The middle and lower alveolar thicknesses and labial alveolar bone area increased in the experimental group. In the control group, the upper and middle alveolar thicknesses and labial alveolar bone area decreased significantly. There were no significant differences in dentoalveolar changes between the 3 kinds of anterior teeth in each group, except for root length in the experimental group (P <0.05). Augmented corticotomy provided a favorable decompensation pattern of the mandibular incisors, preserving the periodontal structures surrounding the mandibular anterior teeth for skeletal Class III patients. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  19. Clinical outcomes of an osteotome technique and simultaneous placement of Neoss implants in the posterior maxilla.

    PubMed

    Volpe, Stefano; Lanza, Massimiliano; Verrocchi, Damiano; Sennerby, Lars

    2013-02-01

    Insufficient bone volume often hamper placement of dental implants in the posterior maxilla. The aim of the present clinical study was to evaluate retrospectively the clinical outcome of implant placement in the resorbed posterior maxilla using an osteotome technique without adding any grafting material. Twenty patients with 5 to 9 mm of residual alveolar bone height in the posterior maxilla received twenty-nine implants (Neoss Ltd., Harrogate, UK) using an osteotomy technique without bone grafts. Intraoral radiographs were taken before and after implant placement, at the time of loading and after 11 to 32 months of loading (mean 16.4 months), to evaluate bone formation below the sinus membrane and marginal bone loss. Implant stability measurements (Osstell(TM) , Gothenburg, Sweden) were performed after implant installation and at abutment connection 5 months later. All implants were installed with the prosthetic platform level with the bone crest. No implant was lost giving a survival rate of 100% after a mean follow-up time of 16.4 months. The average vertical bone height was 7.2 ± 1.5 mm at placement and 10.0 ± 1.0 mm after 11 to 32 months. The average increase of 2.8 ± 1.1 mm was statistically significant. There was a statistically significant improvement in implant stability from 70.7 ± 9.2 implant stability quotient (ISQ) at placement to 76.7 ± 5.7 ISQ at abutment connection, 5 months later. The mean marginal bone loss amounted to 0.7 ± 0.3 mm after 11 to 32 months of loading. It is concluded that the osteotome technique evaluated resulted in predictable intrasinus bone formation, firm implant stability, and good clinical outcomes as no implants were lost and minimal marginal bone loss was observed. © 2011 Wiley Periodicals, Inc.

  20. Ballistic stretching increases flexibility and acute vertical jump height when combined with basketball activity.

    PubMed

    Woolstenhulme, Mandy T; Griffiths, Christine M; Woolstenhulme, Emily M; Parcell, Allen C

    2006-11-01

    Stretching is often included as part of a warm-up procedure for basketball activity. However, the efficacy of stretching with respect to sport performance has come into question. We determined the effects of 4 different warm-up protocols followed by 20 minutes of basketball activity on flexibility and vertical jump height. Subjects participated in 6 weeks (2 times per week) of warm-up and basketball activity. The warm-up groups participated in ballistic stretching, static stretching, sprinting, or basketball shooting (control group). We asked 3 questions. First, what effect does 6 weeks of warm-up exercise and basketball play have on both flexibility and vertical jump height? We measured sit and reach and vertical jump height before (week -1) and after (week 7) the 6 weeks. Flexibility increased for the ballistic, static, and sprint groups compared to the control group (p < 0.0001), while vertical jump height did not change for any of the groups. Our second question was what is the acute effect of each warm-up on vertical jump height? We measured vertical jump immediately after the warm-up on 4 separate occasions during the 6 weeks (at weeks 0, 2, 4, and 6). Vertical jump height was not different for any group. Finally, our third question was what is the acute effect of each warm-up on vertical jump height following 20 minutes of basketball play? We measured vertical jump height immediately following 20 minutes of basketball play at weeks 0, 2, 4, and 6. Only the ballistic stretching group demonstrated an acute increase in vertical jump 20 minutes after basketball play (p < 0.05). Coaches should consider using ballistic stretching as a warm-up for basketball play, as it is beneficial to vertical jump performance.

  1. Evaluation of bone, nutrition, and physical function in Shorinji Kempo athletes

    PubMed Central

    Sumida, Sachiko; Iwamoto, Jun; Kamide, Naoto; Otani, Toshiro

    2012-01-01

    The objectives of this study were to reveal the proportion of Shorinji Kempo athletes who had suffered fractures related to sports activities, and to evaluate bone mass, bone turnover, nutritional status, and physical function in these athletes. A medical examination was carried out for 16 Shorinji Kempo collegiate athletes. Seven athletes (43.8%) had experienced a sports-related traumatic fracture during Shorinji Kempo practice. Four athletes (25.0%) had a lower speed of sound (% young adult mean < 100%), and five athletes (31.3%) had higher levels of urinary cross-linked N-terminal telopeptides of type 1 collagen (a bone turnover marker) than the age-adjusted standard values. All the athletes had a lower daily calcium intake than the adequate intake, 12 (75.0%) had a lower daily vitamin D intake, and 15 (93.8%) had a lower daily vitamin K intake. Significant positive correlations were found between the vertical jump height, and the daily energy, and protein intakes. Results suggest that fractures are a common injury in Shorinji Kempo athletes, and that some Shorinji Kempo athletes need to improve their bone mass, bone metabolism, and nutritional status in order to strengthen bone and improve physical function. PMID:24198593

  2. Two-Stage Surgical Management of Multilevel Symptomatic Thoracic Haemangioma Using Ethanol and Iliac Crest Bone Graft

    PubMed Central

    Brahmajoshyula, Venkatramana; Mayi, Shivanand; Teegala, Suman

    2014-01-01

    This article presents a 56-year-old obese female who presented with back pain and progressive weakness in her lower limbs for three months. She was bed-ridden for one week before reporting to our hospital. Plain radiographs showed vertical striations in multiple vertebrae classical of haemangioma. Magnetic resonance imaging (MRI) spine revealed multiple thoracic and lumbar vertebral haemangiomas. Extra osseous extension of haemangioma at T12 was causing spinal cord compression. Two-stage surgery was performed with absolute alcohol (ethanol) injection followed by pedicle screw fixation and decompression with tricortical iliac crest bone graft into the vertebral body. Postoperatively rapid neurological improvement was seen. After three weeks, she could walk independently. One year later, computed tomography showed complete incorporation of bone graft and maintained vertebral body height. MRI showed complete resolution of the cord edema at T12. These findings indicated diminished vascularity of the tumor. PMID:25187869

  3. Cephalometric risk factors of obstructive sleep apnea.

    PubMed

    Bayat, Mohamad; Shariati, Mahsa; Rakhshan, Vahid; Abbasi, Mohsen; Fateh, Ali; Sobouti, Farhad; Davoudmanesh, Zeinab

    2017-09-01

    Previous studies on risk factors of obstructive sleep apnea (OSA) are highly controversial and mostly identifying a few cephalometric risk factors. OSA diagnosis was made according to the patients' apnea-hypopnea index (AHI). Included were 74 OSA patients (AHI > 10) and 52 control subjects (AHI ≤ 10 + free of other OSA symptoms). In both groups, 18 cephalometric parameters were traced (SNA, SNB, ANB, the soft palate's length (PNS-P), inferior airway space, the distance from the mandibular plane to the hyoid (MP-H), lengths of mandible (Go-Gn) and maxilla (PNS-ANS), vertical height of airway (VAL), vertical height of the posterior maxilla (S-PNS), superior posterior airway space (SPAS), middle airway space, distances from hyoid to third cervical vertebra and retrognathion (HH1), C3 (C3H), and RGN (HRGN), the maximum thickness of soft palate (MPT), tongue length (TGL), and the maximum height of tongue). These parameters were compared using t-test. Significant variables were SPAS (p = 0.027), MPT, TGL, HH1, C3H, HRGN, PNS-P, S-PNS, MP-H, VAL, and Go-Gn (all p values ≤ 0.006). OSA patients exhibited thicker and longer soft palates, hyoid bones more distant from the vertebrae, retrognathion, and mandibular plane, higher posterior maxillae, longer mandibles, and smaller superior-posterior airways.

  4. Graft shrinkage and survival rate of implants after sinus floor elevation using a nanocrystalline hydroxyapatite embedded in silica gel matrix: a 1-year prospective study.

    PubMed

    El Hage, Marc; Abi Najm, Semaan; Bischof, Mvark; Nedir, Rabah; Carrel, Jean-Pierre; Bernard, Jean-Pierre

    2012-06-01

    The aims of this study were (1) to evaluate the vertical shrinkage percentage of nanocrystalline hydroxyapatite embedded in silica gel used for maxillary sinus floor elevation (SFE) and (2) to determine the survival rate of the implants 1 year after placement in the healed grafted sinuses. Eleven maxillary sinuses were augmented in eight patients with NanoBone. After a healing period averaging 14.42 months, 19 implants were placed and followed up with clinical and radiographic evaluation. Panoramic radiographs were taken immediately after SFE and at 12 months after grafting. Measurements of changes in height were made by a computerized measuring technique using an image editing software. The mean graft height shrinkage percentage at 12 months after surgery was 8.84% (±5.32). One implant was lost before loading. All the 18 remaining osseointegrated implants received the prosthetic rehabilitation and were controlled after 3 months of functional loading. The implant survival rate at the 1-year interval was 94.74%. A 100% NanoBone alloplastic graft used in lateral SFE procedures presented limited height shrinkage. Implants placed in these grafted sinuses showed survival rates similar to those found in published data. These results should be interpreted cautiously considering the study's reduced sample size.

  5. Direct metal laser sintering (DMLS) of a customized titanium mesh for prosthetically guided bone regeneration of atrophic maxillary arches.

    PubMed

    Ciocca, L; Fantini, M; De Crescenzio, F; Corinaldesi, G; Scotti, R

    2011-11-01

    This study describes a protocol for the direct manufacturing of a customized titanium mesh using CAD-CAM procedures and rapid prototyping to augment maxillary bone and minimize surgery when severe atrophy or post-oncological deformities are present. Titanium mesh and particulate autogenous plus bovine demineralised bone were planned for patient rehabilitation. Bone augmentation planning was performed using the pre-op CT data set in relation to the prosthetic demands, minimizing the bone volume to augment at the minimum necessary for implants. The containment mesh design was used to prototype the 0.6 mm thickness customized titanium mesh, by direct metal laser sintering. The levels of regenerated bone were calculated using the post-op CT data set, through comparison with the pre-op CT data set. The mean vertical height difference of the crestal bone was 2.57 mm, while the mean buccal-palatal dimension of thickness difference was 3.41 mm. All planned implants were positioned after an 8 month healing period using two-step implant surgery, and finally restored with a partial fixed prosthesis. We present a viable and reproducible method to determine the correct bone augmentation prior to implant placement and CAD-CAM to produce a customized direct laser-sintered titanium mesh that can be used for bone regeneration.

  6. Mean alveolar bone crest height decrement in subjects with an osteoporosis risk

    NASA Astrophysics Data System (ADS)

    Effrianto, H. P. S.; Priminiarti, M.; Makes, B. N.

    2017-08-01

    People 40-75 years of age have an osteoporosis risk that may be signaled by a decrease in alveolar bone crest height. Thus, this measure can be used as an indicator of osteoporosis risk. This study was conducted to provide a database of decreased alveolar bone crest heights in ages at risk of osteoporosis by using intraoral radiographs. Forty periapical radiographs of the posterior region of tooth 36 (or 46) were measured twice at different times by two different observers. The interproximal decrease in alveolar bone crest height was measured from the alveolar bone crest to the cementoenamel junction (CEJ) for each tooth on the mesial and distal sides using a ruler (mm). The mean decrease in alveolar bone crest height in at-risk ages for osteoporosis was 3.50±1.085 mm, with a mean of 3.15±0.864 mm for those 45-59 years of age, and 3.90±1.156 mm for those aged 60-75 years. The mean decrease in alveolar bone crest height in people 60-75 years of age was larger than in people 45-59 years of age. There was a medium correlation between age and decreased alveolar bone crest height.

  7. A randomized controlled clinical trial comparing small buccal dehiscence defects around dental implants treated with guided bone regeneration or left for spontaneous healing.

    PubMed

    Jung, Ronald E; Herzog, Milan; Wolleb, Karin; Ramel, Christian F; Thoma, Daniel S; Hämmerle, Christoph H F

    2017-03-01

    The aim of the present randomized controlled clinical study was to test whether small bony dehiscence defects (≤5 mm) left to heal spontaneously result in the same clinical and radiological outcome as defects treated with guided bone regeneration (GBR). Twenty-two patients who received at least one implant with a small bony dehiscence defect were enrolled in the study. If the defect height was ≤5 mm, the site was randomly assigned to either the spontaneous healing (SH) group or the GBR group. In the SH group, the defect was left without any treatment. In the GBR group, the defects around the implants were grafted with deproteinized bovine bone mineral (DBBM) and covered with a native collagen membrane. Clinical and radiographic measurements were performed 6 months after implant placement with a reentry surgery and at the time of crown insertion and the subsequent follow-up appointments at 3, 6, 12 and 18 months after loading. For statistical analyses, the mixed linear model was applied for the clinical and radiographic measurements observed around the implants. Simple comparisons of the location of the measurements in the two independent groups are performed with the Mann-Whitney U-test. In addition, the mixed model assumptions were checked. The implant and crown survival rate 18 months after loading was 100%, revealing no serious biologic or prosthetic complication. The mean changes of the buccal vertical bone height between implant placement and reentry surgery after 6 months revealed a small bone loss of -0.17 ± 1.79 mm (minimum -4 mm and maximum 2.5 mm) for the SH group and a bone gain of 1.79 ± 2.24 mm (minimum of -2.5 mm and maximum of 5 mm) for the GBR group, respectively (P = 0.017). Radiographic measurements demonstrated a slight bone loss of -0.39 ± 0.49 mm for the SH group and a stable bone level of 0.02 ± 0.48 mm for GBR group after 18 months. All peri-implant soft tissue parameters revealed healthy tissues with no difference between the two groups. Small bony dehiscence defects left for spontaneous healing demonstrated high implant survival rates with healthy and stable soft tissues. However, they revealed more vertical bone loss at the buccal aspect 6 months after implant insertion and also more marginal bone loss between crown insertion and 18 months after loading compared to sites treated with GBR. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Childhood growth predicts higher bone mass and greater bone area in early old age: findings among a subgroup of women from the Helsinki Birth Cohort Study.

    PubMed

    Mikkola, T M; von Bonsdorff, M B; Osmond, C; Salonen, M K; Kajantie, E; Cooper, C; Välimäki, M J; Eriksson, J G

    2017-09-01

    We examined the associations between childhood growth and bone properties among women at early old age. Early growth in height predicted greater bone area and higher bone mineral mass. However, information on growth did not improve prediction of bone properties beyond that predicted by body size at early old age. We examined the associations between body size at birth and childhood growth with bone area, bone mineral content (BMC), and areal bone mineral density (aBMD) in early old age. A subgroup of women (n = 178, mean 60.4 years) from the Helsinki Birth Cohort Study, born 1934-1944, participated in dual-energy X-ray absorptiometry (DXA) measurements of the lumbar spine and hip. Height and weight at 0, 2, 7, and 11 years, obtained from health care records, were reconstructed into conditional variables representing growth velocity independent of earlier growth. Weight was adjusted for corresponding height. Linear regression models were adjusted for multiple confounders. Birth length and growth in height before 7 years of age were positively associated with femoral neck area (p < 0.05) and growth in height at all age periods studied with spine bone area (p < 0.01). Growth in height before the age of 7 years was associated with BMC in the femoral neck (p < 0.01) and birth length and growth in height before the age of 7 years were associated with BMC in the spine (p < 0.05). After entering adult height into the models, nearly all associations disappeared. Weight gain during childhood was not associated with bone area or BMC, and aBMD was not associated with early growth. Optimal growth in height in girls is important for obtaining larger skeleton and consequently higher bone mass. However, when predicting bone mineral mass among elderly women, information on early growth does not improve prediction beyond that predicted by current height and weight.

  9. On density differences of some parts of body of men living on hypsometrically contrasting tectonic blocks

    NASA Astrophysics Data System (ADS)

    Kochemasov, G. G.

    In microgravity conditions in cosmos above the Earth s surface 100 and more km man diminishes density of its bones losing Ca This phenomenon appears instantaneously after arriving man in orbit If an abrupt hundred km vertical change produces very sharp and prompt result then a smaller vertical difference in terrestrial habitation 1 to 5 km but during thousand and thousand years should have some steady and noticeable results Let us compare some characteristics of man living in two tectonic segments the higher eastern and lower western hemispheres in two tectonic sectors the lower Eurasian and higher Asian sectors in two tectonic granules of Africa Pygmy of the Congolese lowlands and Bushman of the South-African highlands Polynesians of Pacific and Indians of America the western hemisphere have on average higher the Rohrer s index the ratio of body weight to the cube of its height than population of the eastern hemisphere A calf of a Polynesian is 25 longer in circumference than that of Hottentot Hand contraction of a Polynesian on average is stronger than that of a Breton fisherman Crania of the Changos - past Indians of the Atakama desert a very low part of the American continent -- are very strong with thick-bones and with cartilage joining skull bones thickness of skull bones is also a characteristic of other Indians So if an astronaut above loses his calcium an Indian below acquires additional calcium for his bones Composition and quantity of human hairs characteristically changes from uplifted to subsided -

  10. Applied anatomic site study of palatal anchorage implants using cone beam computed tomography.

    PubMed

    Lai, Ren-fa; Zou, Hui; Kong, Wei-dong; Lin, Wei

    2010-06-01

    The purpose of this study was to conduct quantitative research on bone height and bone mineral density of palatal implant sites for implantation, and to provide reference sites for safe and stable palatal implants. Three-dimensional reformatting images were reconstructed by cone beam computed tomography (CBCT) in 34 patients, aged 18 to 35 years, using EZ Implant software. Bone height was measured at 20 sites of interest on the palate. Bone mineral density was measured at the 10 sites with the highest implantation rate, classified using K-mean cluster analysis based on bone height and bone mineral density. According to the cluster analysis, 10 sites were classified into three clusters. Significant differences in bone height and bone mineral density were detected between these three clusters (P<0.05). The greatest bone height was obtained in cluster 2, followed by cluster 1 and cluster 3. The highest bone mineral density was found in cluster 3, followed by cluster 1 and cluster 2. CBCT plays an important role in pre-surgical treatment planning. CBCT is helpful in identifying safe and stable implantation sites for palatal anchorage.

  11. 49 CFR 581.7 - Test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... is vertical and the impact line is horizontal at the specified height. (3) For impacts at a height... Figure 1 so that Plane A is vertical and the impact line is horizontal at the specified height. (3) For... that Plane A is vertical and the impact line is horizontal at a height within the range. (4) Align the...

  12. 49 CFR 399.207 - Truck and truck-tractor access requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... requirements: (1) Vertical height. All measurements of vertical height shall be made from ground level with the... vertical height of the first step shall be no more than 609 millimeters (24 inches) from ground level. (3... requirement. The step need not retain the disc at rest. (5) Step strength. Each step must withstand a vertical...

  13. 49 CFR 399.207 - Truck and truck-tractor access requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... requirements: (1) Vertical height. All measurements of vertical height shall be made from ground level with the... vertical height of the first step shall be no more than 609 millimeters (24 inches) from ground level. (3... requirement. The step need not retain the disc at rest. (5) Step strength. Each step must withstand a vertical...

  14. 49 CFR 399.207 - Truck and truck-tractor access requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... requirements: (1) Vertical height. All measurements of vertical height shall be made from ground level with the... vertical height of the first step shall be no more than 609 millimeters (24 inches) from ground level. (3... requirement. The step need not retain the disc at rest. (5) Step strength. Each step must withstand a vertical...

  15. 49 CFR 399.207 - Truck and truck-tractor access requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... requirements: (1) Vertical height. All measurements of vertical height shall be made from ground level with the... vertical height of the first step shall be no more than 609 millimeters (24 inches) from ground level. (3... requirement. The step need not retain the disc at rest. (5) Step strength. Each step must withstand a vertical...

  16. Autogenous bone versus deproteinised bovine bone matrix in 1-stage lateral sinus floor elevation in the severely atrophied maxilla: a randomised controlled trial.

    PubMed

    Merli, Mauro; Moscatelli, Marco; Mariotti, Giorgia; Rotundo, Roberto; Nieri, Michele

    2013-01-01

    To compare 100% deproteinised bovine bone matrix (DBBM) grafts (test group) with 100% autogenous bone (AB) grafts (control group) for lateral maxillary sinus floor elevation in a parallel group, superiority, randomised controlled trial. Patients with 1 to 3 mm of residual bone height below the maxillary sinus were randomised for sinus floor elevation with DBBM and AB grafts and simultaneous implant placement. Randomisation was computer generated with allocation concealment by sealed envelopes and the radiographic examiner was blinded to group assignment. The abutment connection was performed 8 months after surgery and insertion of the provisional prostheses was performed 9 months after surgery. Outcome variables were implant failures, prosthetic failures, complications, chair time, postoperative pain and radiographic bone level 6 months after loading. Forty patients were randomised: 20 (32 implants) to the DBBM group and 20 (27 implants) to the AB group. One patient from the AB group dropped out. Two implant failures occurred in the DBBM group and no implant failure occurred in the AB group (P = 0.4872). All of the planned prostheses could be delivered. One complication occurred in the DBBM group and 2 in the AB group (P = 0.6050). Chair time was shorter for the DBBM group, with a difference of 27.3 minutes (P = 0.0428). Pain difference measured with a visual analogue scale for 6 days post-surgery was 0.2 in favour of the DBBM group (P = 0.6838). The difference in vertical bone height was 0.0 mm (95% CI -1.1, 1.1; P = 0.9703) and the difference in marginal bone level was 0.3 in favour of AB (95% CI -0.3, 0.9; P = 0.3220). No differences apart from chair time were observed when comparing DBBM and AB grafts with simultaneous implant placement in sinus elevation.

  17. Management of Limited Vertical Bone Height in the Posterior Mandible: Short Dental Implants Versus Nerve Lateralization With Standard Length Implants.

    PubMed

    Dursun, Erhan; Keceli, Huseyin Gencay; Uysal, Serdar; Güngör, Hamiyet; Muhtarogullari, Mehmet; Tözüm, Tolga Fikret

    2016-05-01

    Inferior alveolar nerve lateralization (IANL) and short dental implants (SDI) are 2 viable implant-based treatment approaches in the presence of atrophied posterior mandible. Despite the risks of dysfunction, infection, and pathologic fractures in IANL, it becomes possible to place standard implants. The purpose of this study was to compare SDI and IANL approaches from clinical and radiographic aspects. Fifteen subjects having unilateral atrophic mandibles were allocated to SDI and IANL treatment groups. Following surgical procedures, early postoperative complications, implant survival, and periimplant clinical and radiographic parameters including probing pocket depth, attachment level, keratinized tissue amount, vertical tissue recession, and marginal bone loss were recorded at baseline and 1-year after prosthetic rehabilitation. In both groups, no implant was lost. Except usual postoperative complications, 2 patients had transient paraesthesia after IANL. According to time-dependent evaluation, both groups showed significant increase in probing pocket depth and attachment level at 1-year follow-up compared with baseline (P < 0.05). Except a slight but significant increase in mesial surface of SDI group (P < 0.05), no remarkable time-dependent change was identified in vertical tissue recession. Keratinized tissue amount did not exhibit any inter- or intragroup difference during whole study period. Marginal bone loss did not show any difference between IANL and SDI groups at follow-up. SDI placement or standard length implant placement with IANL can be considered promising alternatives in the treatment of atrophic mandibular posterior regions. However, SDI may be preferred in terms of lower complication risk.

  18. Validation of the iPhone app using the force platform to estimate vertical jump height.

    PubMed

    Carlos-Vivas, Jorge; Martin-Martinez, Juan P; Hernandez-Mocholi, Miguel A; Perez-Gomez, Jorge

    2018-03-01

    Vertical jump performance has been evaluated with several devices: force platforms, contact mats, Vertec, accelerometers, infrared cameras and high-velocity cameras; however, the force platform is considered the gold standard for measuring vertical jump height. The purpose of this study was to validate an iPhone app called My Jump, that measures vertical jump height by comparing it with other methods that use the force platform to estimate vertical jump height, namely, vertical velocity at take-off and time in the air. A total of 40 sport sciences students (age 21.4±1.9 years) completed five countermovement jumps (CMJs) over a force platform. Thus, 200 CMJ heights were evaluated from the vertical velocity at take-off and the time in the air using the force platform, and from the time in the air with the My Jump mobile application. The height obtained was compared using the intraclass correlation coefficient (ICC). Correlation between APP and force platform using the time in the air was perfect (ICC=1.000, P<0.001). Correlation between APP and force platform using the vertical velocity at take-off was also very high (ICC=0.996, P<0.001), with an error margin of 0.78%. Therefore, these results showed that application, My Jump, is an appropriate method to evaluate the vertical jump performance; however, vertical jump height is slightly overestimated compared with that of the force platform.

  19. Minimum Abutment Height to Eliminate Bone Loss: Influence of Implant Neck Design and Platform Switching.

    PubMed

    Spinato, Sergio; Galindo-Moreno, Pablo; Bernardello, Fabio; Zaffe, Davide

    This retrospective study quantitatively analyzed the minimum prosthetic abutment height to eliminate bone loss after 4.7-mm-diameter implant placement in maxillary bone and how grafting techniques can affect the marginal bone loss in implants placed in maxillary areas. Two different implant types with a similar neck design were singularly placed in two groups of patients: the test group, with platform-switched implants, and the control group, with conventional (non-platform-switched) implants. Patients requiring bone augmentation underwent unilateral sinus augmentation using a transcrestal technique with mineralized xenograft. Radiographs were taken immediately after implant placement, after delivery of the prosthetic restoration, and after 12 months of loading. The average mesial and distal marginal bone loss of the control group (25 patients) was significantly more than twice that of the test group (26 patients), while their average abutment height was similar. Linear regression analysis highlighted a statistically significant inverse relationship between marginal bone loss and abutment height in both groups; however, the intercept of the regression line, both mesially and distally, was 50% lower for the test group than for the control group. The marginal bone loss was annulled with an abutment height of 2.5 mm for the test group and 3.0 mm for the control group. No statistically significant differences were found regarding marginal bone loss of implants placed in native maxillary bone compared with those placed in the grafted areas. The results suggest that the shorter the abutment height, the greater the marginal bone loss in cement-retained prostheses. Abutment height showed a greater influence in platform-switched than in non-platform-switched implants on the limitation of marginal bone loss.

  20. Effect of alveolar ridge preservation after tooth extraction: a systematic review and meta-analysis.

    PubMed

    Avila-Ortiz, G; Elangovan, S; Kramer, K W O; Blanchette, D; Dawson, D V

    2014-10-01

    Alveolar ridge preservation strategies are indicated to minimize the loss of ridge volume that typically follows tooth extraction. The aim of this systematic review was to determine the effect that socket filling with a bone grafting material has on the prevention of postextraction alveolar ridge volume loss as compared with tooth extraction alone in nonmolar teeth. Five electronic databases were searched to identify randomized clinical trials that fulfilled the eligibility criteria. Literature screening and article selection were conducted by 3 independent reviewers, while data extraction was performed by 2 independent reviewers. Outcome measures were mean horizontal ridge changes (buccolingual) and vertical ridge changes (midbuccal, midlingual, mesial, and distal). The influence of several variables of interest (i.e., flap elevation, membrane usage, and type of bone substitute employed) on the outcomes of ridge preservation therapy was explored via subgroup analyses. We found that alveolar ridge preservation is effective in limiting physiologic ridge reduction as compared with tooth extraction alone. The clinical magnitude of the effect was 1.89 mm (95% confidence interval [CI]: 1.41, 2.36; p < .001) in terms of buccolingual width, 2.07 mm (95% CI: 1.03, 3.12; p < .001) for midbuccal height, 1.18 mm (95% CI: 0.17, 2.19; p = .022) for midlingual height, 0.48 mm (95% CI: 0.18, 0.79; p = .002) for mesial height, and 0.24 mm (95% CI: -0.05, 0.53; p = .102) for distal height changes. Subgroup analyses revealed that flap elevation, the usage of a membrane, and the application of a xenograft or an allograft are associated with superior outcomes, particularly on midbuccal and midlingual height preservation. © International & American Associations for Dental Research.

  1. A three-dimensional analysis of skeletal and dental characteristics in skeletal class III patients with facial asymmetry.

    PubMed

    Yu, Jinfeng; Hu, Yun; Huang, Mingna; Chen, Jun; Ding, Xiaoqian; Zheng, Leilei

    2018-03-15

    To evaluate the skeletal and dental characteristics in skeletal class III patients with facial asymmetry and to analyse the relationships among various parts of the stomatognathic system to provide a theoretical basis for clinical practice. Asymmetric cone-beam computed tomography data acquired from 56 patients were evaluated using Mimics 10.0 and 3-Matic software. Skeletal and dental measurements were performed to assess the three-dimensional differences between two sides. Pearson correlation analysis was used to determine the correlations among measurements. Linear measurements, such as ramal height, mandible body length, ramal height above the sigmoid notch (RHASN), maxillary height, condylar height, buccal and total cancellous bone thickness, and measurements of condylar size, were significantly larger on the nondeviated side than on the deviated side (P <  0.05). Crown root ratio and buccolingual angle of mandibular first molar were found to be significantly smaller on the nondeviated side than on the deviated side (P <  0.05). A negative correlation was also discovered between the buccolingual angle of mandibular first molar and the ramal height (P <  0.01). In patients with facial asymmetry, asymmetries in the mandible, maxilla and condylar morphology, and skeletal canting served as major components of skeletal asymmetry. Furthermore, a reduced thickness of buccal cancellous bone and a larger crown root ratio were found on the deviated side, indicating that orthodontic camouflage has limitations and potential risks. A combination of orthodontics and orthognathic surgery may be the advisable choice in patients with a menton deviation greater than 4 mm. An important association between vertical skeletal disharmony and dental compensation was also observed.

  2. Horizontal alveolar bone loss: A periodontal orphan

    PubMed Central

    Jayakumar, A.; Rohini, S.; Naveen, A.; Haritha, A.; Reddy, Krishnanjeneya

    2010-01-01

    Background: Attempts to successfully regenerate lost alveolar bone have always been a clinician’s dream. Angular defects, at least, have a fairer chance, but the same cannot be said about horizontal bone loss. The purpose of the present study was to evaluate the prevalence of horizontal alveolar bone loss and vertical bone defects in periodontal patients; and later, to correlate it with the treatment modalities available in the literature for horizontal and vertical bone defects. Materials and Methods: The study was conducted in two parts. Part I was the radiographic evaluation of 150 orthopantomographs (OPGs) (of patients diagnosed with chronic periodontitis and seeking periodontal care), which were digitized and read using the AutoCAD 2006 software. All the periodontitis-affected teeth were categorized as teeth with vertical defects (if the defect angle was ≤45° and defect depth was ≥3 mm) or as having horizontal bone loss. Part II of the study comprised search of the literature on treatment modalities for horizontal and vertical bone loss in four selected periodontal journals. Results: Out of the 150 OPGs studied, 54 (36%) OPGs showed one or more vertical defects. Totally, 3,371 teeth were studied, out of which horizontal bone loss was found in 3,107 (92.2%) teeth, and vertical defects were found only in 264 (7.8%) of the teeth, which was statistically significant (P<.001). Search of the selected journals revealed 477 papers have addressed the treatment modalities for vertical and horizontal types of bone loss specifically. Out of the 477 papers, 461 (96.3%) have addressed vertical bone loss, and 18 (3.7%) have addressed treatment options for horizontal bone loss. Two papers have addressed both types of bone loss and are included in both categories. Conclusion: Horizontal bone loss is more prevalent than vertical bone loss but has been sidelined by researchers as very few papers have been published on the subject of regenerative treatment modalities for this type of bone loss. This study should be an impetus for greater attention to an otherwise ubiquitous periodontal challenge. PMID:21760673

  3. Guided Bone Regeneration Using Collagen Scaffolds, Growth Factors, and Periodontal Ligament Stem Cells for Treatment of Peri-Implant Bone Defects In Vivo

    PubMed Central

    Scholz, Malte; Baudisch, Maria; Liese, Jan; Frerich, Bernhard; Lang, Hermann

    2017-01-01

    Introduction The aim of the study was an evaluation of different approaches for guided bone regeneration (GBR) of peri-implant defects in an in vivo animal model. Materials and Methods In minipigs (n = 15), peri-implant defects around calcium phosphate- (CaP-; n = 46) coated implants were created and randomly filled with (1) blank, (2) collagen/hydroxylapatite/β-tricalcium phosphate scaffold (CHT), (3) CHT + growth factor cocktail (GFC), (4) jellyfish collagen matrix, (5) jellyfish collagen matrix + GFC, (6) collagen powder, and (7) collagen powder + periodontal ligament stem cells (PDLSC). Additional collagen membranes were used for coverage of the defects. After 120 days of healing, bone growth was evaluated histologically (bone to implant contact (BIC;%)), vertical bone apposition (VBA; mm), and new bone height (NBH; %). Results In all groups, new bone formation was seen. Though, when compared to the blank group, no significant differences were detected for all parameters. BIC and NBH in the group with collagen matrix as well as the group with the collagen matrix + GFC were significantly less when compared to the collagen powder group (all: p < 0.003). Conclusion GBR procedures, in combination with CaP-coated implants, will lead to an enhancement of peri-implant bone growth. There was no additional significant enhancement of osseous regeneration when using GFC or PDLSC. PMID:28951742

  4. Guided Bone Regeneration Using Collagen Scaffolds, Growth Factors, and Periodontal Ligament Stem Cells for Treatment of Peri-Implant Bone Defects In Vivo.

    PubMed

    Kämmerer, Peer W; Scholz, Malte; Baudisch, Maria; Liese, Jan; Wegner, Katharina; Frerich, Bernhard; Lang, Hermann

    2017-01-01

    The aim of the study was an evaluation of different approaches for guided bone regeneration (GBR) of peri-implant defects in an in vivo animal model. In minipigs ( n = 15), peri-implant defects around calcium phosphate- (CaP-; n = 46) coated implants were created and randomly filled with (1) blank, (2) collagen/hydroxylapatite/ β -tricalcium phosphate scaffold (CHT), (3) CHT + growth factor cocktail (GFC), (4) jellyfish collagen matrix, (5) jellyfish collagen matrix + GFC, (6) collagen powder, and (7) collagen powder + periodontal ligament stem cells (PDLSC). Additional collagen membranes were used for coverage of the defects. After 120 days of healing, bone growth was evaluated histologically (bone to implant contact (BIC;%)), vertical bone apposition (VBA; mm), and new bone height (NBH; %). In all groups, new bone formation was seen. Though, when compared to the blank group, no significant differences were detected for all parameters. BIC and NBH in the group with collagen matrix as well as the group with the collagen matrix + GFC were significantly less when compared to the collagen powder group (all: p < 0.003). GBR procedures, in combination with CaP-coated implants, will lead to an enhancement of peri-implant bone growth. There was no additional significant enhancement of osseous regeneration when using GFC or PDLSC.

  5. Effect of prescribed prism on monocular interpupillary distances and fitting heights for progressive add lenses.

    PubMed

    Brooks, C W; Riley, H D

    1994-06-01

    Success in fitting progressive addition lenses is dependent upon the accurate placement of the progressive zone. Both eyes must track simultaneously within the boundary of the progressive corridor. Vertical prism will displace the wearer's lines of sight and consequently eye position. Because fitting heights are measured using an empty frame, subjects with vertical phorias usually will fuse, and not show the vertical differences in pupil heights during the measuring process. Therefore, when prescriptions contain vertical prism one must consider the changes in measured fitting heights that will occur once the lenses are placed in the frame. Fitting heights must be altered approximately 0.3 mm for each vertical prism diopter prescribed. The fitting height adjustment is opposite from the base direction of the prescribed prism. An explanation of the effect of prescribed horizontal prism on monocular interpupillary distance (PD) measurements is also included.

  6. Optimizing Maxillary Aesthetics of a Severe Compromised Tooth through Orthodontic Movement and Dental Implants

    PubMed Central

    de Avila, Erica Dorigatti; Cirelli, Joni Augusto; Cardoso, Mauricio de Almeida; Capelozza-Filho, Leopoldino; Borelli Barros, Luiz Antonio

    2014-01-01

    Treatment of severe compromised tooth in the maxillary anterior area still poses great challenge to the clinicians. Several treatment modalities have been proposed to restore the function and aesthetics in teeth with advanced periodontal disease. The present study aims to report a case of traumatic injury of a left-maxillary central incisor with ridge preservation, orthodontic movement, and implant therapy. A 45-year-old woman underwent the proposed treatment for her left central incisor: basic periodontal therapy, xenogenous bone graft, and guided bone regeneration (GBR). Six months after the graft procedure, orthodontic movement by means of alignment and leveling was made and a coronal displacement of the gingival margin and vertical bone apposition could be observed after 13 months of active movement. Afterwards, a dental implant was placed followed by a connective tissue graft and immediate provisionalization of the crown. In conclusion, orthodontic movement was effective to improve the gingival tissue and alveolar bone prior to implant placement favoring the aesthetic results. Six years postoperatively, the results revealed height and width alveolar bone gain indicating that the treatment proposed was able to restore all the functional and aesthetic parameters. PMID:24523969

  7. A novel classification of frontal bone fractures: The prognostic significance of vertical fracture trajectory and skull base extension.

    PubMed

    Garg, Ravi K; Afifi, Ahmed M; Gassner, Jennifer; Hartman, Michael J; Leverson, Glen; King, Timothy W; Bentz, Michael L; Gentry, Lindell R

    2015-05-01

    The broad spectrum of frontal bone fractures, including those with orbital and skull base extension, is poorly understood. We propose a novel classification scheme for frontal bone fractures. Maxillofacial CT scans of trauma patients were reviewed over a five year period, and frontal bone fractures were classified: Type 1: Frontal sinus fracture without vertical extension. Type 2: Vertical fracture through the orbit without frontal sinus involvement. Type 3: Vertical fracture through the frontal sinus without orbit involvement. Type 4: Vertical fracture through the frontal sinus and ipsilateral orbit. Type 5: Vertical fracture through the frontal sinus and contralateral or bilateral orbits. We also identified the depth of skull base extension, and performed a chart review to identify associated complications. 149 frontal bone fractures, including 51 non-vertical frontal sinus (Type 1, 34.2%) and 98 vertical (Types 2-5, 65.8%) fractures were identified. Vertical fractures penetrated the middle or posterior cranial fossa significantly more often than non-vertical fractures (62.2 v. 15.7%, p = 0.0001) and had a significantly higher mortality rate (18.4 v. 0%, p < 0.05). Vertical fractures with frontal sinus and orbital extension, and fractures that penetrated the middle or posterior cranial fossa had the strongest association with intracranial injuries, optic neuropathy, disability, and death (p < 0.05). Vertical frontal bone fractures carry a worse prognosis than frontal bone fractures without a vertical pattern. In addition, vertical fractures with extension into the frontal sinus and orbit, or with extension into the middle or posterior cranial fossa have the highest complication rate and mortality. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis.

    PubMed

    Hong, Hae Ryong; Pae, Ahran; Kim, Yooseok; Paek, Janghyun; Kim, Hyeong-Seob; Kwon, Kung-Rock

    2012-01-01

    The aim of this study was to analyze and compare the level and distribution of peri-implant bone stresses associated with mandibular two-implant overdentures with different implant positions. Mathematical models of mandibles and overdentures were designed using finite element analysis software. Two intraosseous implants and ball attachment systems were placed in the interforaminal region. The overdenture, which was supported by the two implants, was designed to withstand bilateral and unilateral vertical masticatory loads (total 100 N). In all, eight types of models, which differed according to assigned implant positions, height of attachments, and angulation, were tested: MI (model with implants positioned in the lateral incisor sites), MC (implants in canine sites), MP (implants in premolar sites), MI-Hi (greater height of attachments), MC-M (canine implants placed with mesial inclination), MC-D (canine implants placed with distal inclination), MC-B (canine implants placed with buccal inclination), and MC-L (canine implants placed with lingual inclination). Peri-implant bone stress levels associated with overdentures retained by lateral incisor implants resulted in the lowest stress levels and the highest efficiency in distributing peri-implant stress. MI-Hi showed increased stress levels and decreased efficiency in stress distribution. As the implants were inclined, stress levels increased and the efficiency of stress distribution decreased. Among the inclined models, MC-B showed the lowest stress level and best efficiency in stress distribution. The lowest stress and the best stability of implants in mandibular two-implant overdentures were obtained when implants were inserted in lateral incisor areas with shorter attachments and were placed parallel to the long axes of the teeth.

  9. Quantitative morphometric analysis of the lumbar vertebral facets and evaluation of feasibility of lumbar spinal nerve root and spinal canal decompression using the Goel intraarticular facetal spacer distraction technique: A lumbar/cervical facet comparison

    PubMed Central

    Satoskar, Savni R.; Goel, Aimee A.; Mehta, Pooja H.; Goel, Atul

    2014-01-01

    Objective: The authors evaluate the anatomic subtleties of lumbar facets and assess the feasibility and effectiveness of use of ‘Goel facet spacer’ in the treatment of degenerative spinal canal stenosis. Materials and Methods: Twenty-five lumbar vertebral cadaveric dried bones were used for the purpose. A number of morphometric parameters were evaluated both before and after the introduction of Goel facet spacers within the confines of the facet joint. Results: The spacers achieved distraction of facets that was more pronounced in the vertical perspective. Introduction of spacers on both sides resulted in an increase in the intervertebral foraminal height and a circumferential increase in the spinal canal dimensions. Additionally, there was an increase in the disc space or intervertebral body height. The lumbar facets are more vertically and anteroposteriorly oriented when compared to cervical facets that are obliquely and transversely oriented. Conclusions: Understanding the anatomical peculiarities of the lumbar and cervical facets can lead to an optimum utilization of the potential of Goel facet distraction arthrodesis technique in the treatment of spinal degenerative canal stenosis. PMID:25558146

  10. Laser Sintered Porous Ti-6Al-4V Implants Stimulate Vertical Bone Growth.

    PubMed

    Cheng, Alice; Cohen, David J; Kahn, Adrian; Clohessy, Ryan M; Sahingur, Kaan; Newton, Joseph B; Hyzy, Sharon L; Boyan, Barbara D; Schwartz, Zvi

    2017-08-01

    The objective of this study was to examine the ability of 3D implants with trabecular-bone-inspired porosity and micro-/nano-rough surfaces to enhance vertical bone ingrowth. Porous Ti-6Al-4V constructs were fabricated via laser-sintering and processed to obtain micro-/nano-rough surfaces. Male and female human osteoblasts were seeded on constructs to analyze cell morphology and response. Implants were then placed on rat calvaria for 10 weeks to assess vertical bone ingrowth, mechanical stability and osseointegration. All osteoblasts showed higher levels of osteocalcin, osteoprotegerin, vascular endothelial growth factor and bone morphogenetic protein 2 on porous constructs compared to solid laser-sintered controls. Porous implants placed in vivo resulted in an average of 3.1 ± 0.6 mm 3 vertical bone growth and osseointegration within implant pores and had significantly higher pull-out strength values than solid implants. New bone formation and pull-out strength was not improved with the addition of demineralized bone matrix putty. Scanning electron images and histological results corroborated vertical bone growth. This study indicates that Ti-6Al-4V implants fabricated by additive manufacturing to have porosity based on trabecular bone and post-build processing to have micro-/nano-surface roughness can support vertical bone growth in vivo, and suggests that these implants may be used clinically to increase osseointegration in challenging patient cases.

  11. 24 CFR 3285.304 - Pier configuration.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... driven in tightly so that they do not occupy more than one inch of vertical height; and (3) Hardwood... used to fill in any remaining vertical gaps. (d) Manufactured pier heights. Manufactured pier heights...

  12. Hip and knee extensor moments predict vertical jump height in adolescent girls.

    PubMed

    Ford, Kevin R; Myer, Gregory D; Brent, Jensen L; Hewett, Timothy E

    2009-07-01

    Biomechanical factors, such as hip and knee extensor moments, related to drop jump (DJ) performance have not been investigated in adolescent girls. The purpose of this study was to determine the key independent biomechanical variables that predict overall vertical jump performance in adolescent girls. Sixteen high school adolescent girls from club-sponsored and high school-sponsored volleyball teams performed DJ at 3 different drop heights (15, 30, and 45 cm). A motion analysis system consisting of 10 digital cameras and a force platform was used to calculate vertical jump height, joint angles, and joint moments during the tasks. A multiple linear regression was used to determine the biomechanical parameters that were best predictive of vertical jump height at each box drop distance. The 2 predictor variables in all 3 models were knee and hip extensor moments. The models predicted 82.9, 81.9, and 88% of the vertical jump height variance in the 15, 30, and 45 cm trials, respectively. The results of the investigation indicate that knee and hip joint moments are the main contributors to vertical jump height during the DJ in adolescent girls. Strength and conditioning specialists attempting to improve vertical jump performance should target power and strength training to the hip and knee extensors in their athletes.

  13. Cigarette smoking and alveolar bone in young adults: a study using digitized radiographs.

    PubMed

    Rosa, Guillermo M; Lucas, Gabriela Q; Lucas, Oscar N

    2008-02-01

    Evidence indicates that cigarette smoking is one of the most significant risk factors for periodontal diseases; however, there have been few radiographic prospective studies of alveolar bone in young populations. The purpose of this study was to evaluate the effect of smoking on alveolar bone in young adults. Eighty-one dental students (mean age: 20.5 years), considered not to have periodontitis according to clinical criteria, participated in this study. Forty-two subjects were smokers (mean consumption was 14.1 cigarettes/day for > or =2 years), and 39 subjects had never smoked. A parallel-arm prospective design was used. All subjects took part in a dental hygiene program (DHP) that included oral hygiene instructions, mechanical debridement, and polishing. The following clinical variables were measured before and after the DHP: plaque index (PI), gingival crevicular fluid (GCF) flow rate, gingival index (GI), probing depth, and clinical attachment level (CAL). Standardized posterior vertical bitewing radiographs were taken and digitized preexperimentally and on days 180, 365, and 545. The following analyses were performed: bone height measurement (BHM), computer-assisted densitometric image analysis (CADIA), and qualitative analysis of digital subtraction radiography (DSR). Repeated-measures multiple-way analysis of variance (ANOVA) was performed between the groups, and one-way ANOVA was performed within the groups. The mean PI and GI were significantly greater in the smokers (P <0.01). The mean GCF flow rate was significantly lower in the smokers (P <0.01). CAL and the number of sites with recession were significantly greater in the smokers (P <0.001). The BHM indicated a significantly lower mean alveolar bone height in the smokers (P <0.01). The smokers showed significantly lower CADIA values, which indicated a lower bone density on days 0 (P <0.05), 180, 365, and 545 (P <0.01). CADIA values decreased during the study in the smokers, with significant differences on day 545 (P <0.05). The smokers had a significantly higher mean percentage of sites that had decreased density, as assessed by DSR (P <0.001). In the smokers, the mean percentage of sites with decreased density, as assessed by DSR, had increased significantly by days 365 (P <0.05) and 545 (P <0.01). Smoking produces an adverse effect on clinical periodontal variables and alveolar bone height and density, acting as a potential risk factor for alveolar bone loss, even at an early age with low tobacco consumption. It is very important to inform young smokers about the risk of this habit in relation to periodontal health.

  14. Vertical distribution of ozone and the variation of tropopause heights based on ozonesonde and satellite observations. [Contract title: Internal Wave Motion

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Liu, J. M.

    1986-01-01

    The distribution of atmospheric ozone is nonuniform both in space and time. Local ozone concentration vary with altitude, latitude, longitude, and season. Two year ozonesonde data, January 1981 to December 1982, observed at four Canadian stations and 2.5 year backscattered ultraviolet experiment data on the Nimbus-4 satellite, April 1970 to August 1972, observed over five American stations were used to study the relationship between the total ozone, vertical height distribution of the ozone mixing ratio, vertical height distribution of half total ozone, and the local tropopause height. The results show that there is a postive correlation between total ozone in Dobson Units and the tropopause height in terms of atmospheric pressure. This result suggests that local intrusion of the statosphere into the troposphere, or the local decreasing of tropopause height could occur if there is a local increasing of total ozone. A comparison of the vertical height distribution of the ozone mixing ratio, the modified pressure height of half total ozone and the tropopause height shows that the pressure height of an ozone mixing ratio of 0.3 micrograms/g, and the modified pressure height of half total ozone are very well correlated with the tropopause pressure height.

  15. Vertical ridge augmentation with autogenous bone grafts 3 years after loading: resorbable barriers versus titanium-reinforced barriers. A randomized controlled clinical trial.

    PubMed

    Merli, Mauro; Lombardini, Francesco; Esposito, Marco

    2010-01-01

    To compare the efficacy of two different techniques for vertical bone regeneration at implant placement with particulated autogenous bone at 3 years after loading: resorbable collagen barriers supported by osteosynthesis plates and nonresorbable titanium-reinforced expanded polytetrafluoroethylene barriers. Twenty-two partially edentulous patients requiring vertical bone augmentation were randomly allocated to two treatment groups, each composed of 11 patients. Prosthetic and implant failures, complications, the amount of vertically regenerated bone, and peri-implant marginal bone levels were recorded by independent and blinded assessors. The implant site requiring the most vertical bone regeneration was selected in each patient for bone level assessment. The follow-up time ranged from provisional loading to 3 years after loading. Analysis of covariance and paired t tests were conducted to compare means at the .05 level of significance. No patient dropped out or was excluded at the 3-year follow-up. No prosthetic failures and no implant failures or complications occurred after loading. There was no statistically significant difference in bone loss between the two groups at either 1 year or 3 years. Both groups had gradually lost a statistically significant amount of peri-implant bone at 1 and 3 years (P < .05). After 3 years, patients treated with resorbable barriers had lost a mean of 0.55 mm of bone; patients who had received nonresorbable barriers showed a mean of 0.53 mm of bone loss. Up to 3 years after implant loading, no failures or complications occurred and peri-implant marginal bone loss was minimal. Vertically regenerated bone can be successfully maintained after functional loading.

  16. Long-term Evaluation of Peri-implant Bone Level after Reconstruction of Severely Atrophic Edentulous Maxilla via Vertical and Horizontal Guided Bone Regeneration in Combination with Sinus Augmentation: A Case Series with 1 to 15 Years of Loading.

    PubMed

    Urban, Istvan A; Monje, Alberto; Lozada, Jaime L; Wang, Hom-Lay

    2017-02-01

    To the best of the authors' knowledge, there is very limited clinical data on the outcomes of simultaneous guided bone regeneration (GBR) for horizontal and/or vertical bone gain for the reconstruction of severely atrophic edentulous maxilla. Therefore, the purpose of the clinical series presented herein was to clinically evaluate long-term horizontal and vertical bone gain, as well as implant survival rate after reconstruction of severely atrophic edentulous maxillary ridges. Sixteen patients (mean age: 64.6 ± 14.6 years of age) were consecutively treated for vertical and/or horizontal bone augmentation via GBR in combination with bilateral sinus augmentation utilizing a mixture of autologous and anorganic bovine bone. Implant survival, bone gain, intraoperative/postoperative complications and peri-implant bone loss were calculated up to the last follow-up exam. Overall, 122 dental implants were placed into augmented sites and have been followed from 12 to 180 months (mean: 76.5 months). Implant survival was 100% (satisfactory survival rate of 97.5%). Mean bone gain was 5.6 mm (max: 9 mm; min: 3 mm) While vertical bone gain was 5.1 ± 1.8 mm; horizontal bone gain was 7.0 ± 1.5 mm. No intraoperative/postoperative complications were noted. Mean peri-implant bone loss values were consistent within the standards for implant success (1.4 ± 1.0 mm). At patient-level, only one patient who had three implants presented with severe peri-implant bone loss. Complete reconstruction of an atrophied maxilla can be successfully achieved by means of guided bone regeneration for horizontal and/or vertical bone gain including bilateral sinus augmentation using a mixture of anorganic bovine bone and autologous bone. © 2016 Wiley Periodicals, Inc.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Newsom, R. K.; Sivaraman, C.; Shippert, T. R.

    Accurate height-resolved measurements of higher-order statistical moments of vertical velocity fluctuations are crucial for improved understanding of turbulent mixing and diffusion, convective initiation, and cloud life cycles. The Atmospheric Radiation Measurement (ARM) Climate Research Facility operates coherent Doppler lidar systems at several sites around the globe. These instruments provide measurements of clear-air vertical velocity profiles in the lower troposphere with a nominal temporal resolution of 1 sec and height resolution of 30 m. The purpose of the Doppler lidar vertical velocity statistics (DLWSTATS) value-added product (VAP) is to produce height- and time-resolved estimates of vertical velocity variance, skewness, and kurtosismore » from these raw measurements. The VAP also produces estimates of cloud properties, including cloud-base height (CBH), cloud frequency, cloud-base vertical velocity, and cloud-base updraft fraction.« less

  18. Pelvic kinematic method for determining vertical jump height.

    PubMed

    Chiu, Loren Z F; Salem, George J

    2010-11-01

    Sacral marker and pelvis reconstruction methods have been proposed to approximate total body center of mass during relatively low intensity gait and hopping tasks, but not during a maximum effort vertical jumping task. In this study, center of mass displacement was calculated using the pelvic kinematic method and compared with center of mass displacement using the ground-reaction force-impulse method, in experienced athletes (n = 13) performing restricted countermovement vertical jumps. Maximal vertical jumps were performed in a biomechanics laboratory, with data collected using an 8-camera motion analysis system and two force platforms. The pelvis center of mass was reconstructed from retro-reflective markers placed on the pelvis. Jump height was determined from the peak height of the pelvis center of mass minus the standing height. Strong linear relationships were observed between the pelvic kinematic and impulse methods (R² = .86; p < .01). The pelvic kinematic method underestimated jump height versus the impulse method, however, the difference was small (CV = 4.34%). This investigation demonstrates concurrent validity for the pelvic kinematic method to determine vertical jump height.

  19. Melatonin enhances vertical bone augmentation in rat calvaria secluded spaces.

    PubMed

    Shino, Hiromichi; Hasuike, Akira; Arai, Yoshinori; Honda, Masaki; Isokawa, Keitaro; Sato, Shuichi

    2016-01-01

    Melatonin has many roles, including bone remodeling and osseointegration of dental implants. The topical application of melatonin facilitated bone regeneration in bone defects. We evaluated the effects of topical application of melatonin on vertical bone augmentation in rat calvaria secluded spaces. In total, 12 male Fischer rats were used and two plastic caps were fixed in the calvarium. One plastic cap was filled with melatonin powder and the other was left empty. Newly generated bone at bone defects and within the plastic caps was evaluated using micro-CT and histological sections. New bone regeneration within the plastic cap was increased significantly in the melatonin versus the control group. Melatonin promoted vertical bone regeneration in rat calvaria in the secluded space within the plastic cap.

  20. Prediction of vertical jump height from anthropometric factors in male and female martial arts athletes.

    PubMed

    Abidin, Nahdiya Zainal; Adam, Mohd Bakri

    2013-01-01

    Vertical jump is an index representing leg/kick power. The explosive movement of the kick is the key to scoring in martial arts competitions. It is important to determine factors that influence the vertical jump to help athletes improve their leg power. The objective of the present study is to identify anthropometric factors that influence vertical jump height for male and female martial arts athletes. Twenty-nine male and 25 female athletes participated in this study. Participants were Malaysian undergraduate students whose ages ranged from 18 to 24 years old. Their heights were measured using a stadiometer. The subjects were weighted using digital scale. Body mass index was calculated by kg/m(2). Waist-hip ratio was measured from the ratio of waist to hip circumferences. Body fat % was obtained from the sum of four skinfold thickness using Harpenden callipers. The highest vertical jump from a stationary standing position was recorded. The maximum grip was recorded using a dynamometer. For standing back strength, the maximum pull upwards using a handle bar was recorded. Multiple linear regression was used to obtain the relationship between vertical jump height and explanatory variables with gender effect. Body fat % has a significant negative relationship with vertical jump height (P < 0.001). The effect of gender is significant (P < 0.001): on average, males jumped 26% higher than females did. Vertical jump height of martial arts athletes can be predicted by body fat %. The vertical jump for male is higher than for their female counterparts. Reducing body fat by proper dietary planning will help to improve leg power.

  1. Relative net vertical impulse determines jumping performance.

    PubMed

    Kirby, Tyler J; McBride, Jeffrey M; Haines, Tracie L; Dayne, Andrea M

    2011-08-01

    The purpose of this investigation was to determine the relationship between relative net vertical impulse and jump height in a countermovement jump and static jump performed to varying squat depths. Ten college-aged males with 2 years of jumping experience participated in this investigation (age: 23.3 ± 1.5 years; height: 176.7 ± 4.5 cm; body mass: 84.4 ± 10.1 kg). Subjects performed a series of static jumps and countermovement jumps in a randomized fashion to a depth of 0.15, 0.30, 0.45, 0.60, and 0.75 m and a self-selected depth (static jump depth = 0.38 ± 0.08 m, countermovement jump depth = 0.49 ± 0.06 m). During the concentric phase of each jump, peak force, peak velocity, peak power, jump height, and net vertical impulse were recorded and analyzed. Net vertical impulse was divided by body mass to produce relative net vertical impulse. Increasing squat depth corresponded to a decrease in peak force and an increase in jump height and relative net vertical impulse for both static jump and countermovement jump. Across all depths, relative net vertical impulse was statistically significantly correlated to jump height in the static jump (r = .9337, p < .0001, power = 1.000) and countermovement jump (r = .925, p < .0001, power = 1.000). Across all depths, peak force was negatively correlated to jump height in the static jump (r = -0.3947, p = .0018, power = 0.8831) and countermovement jump (r = -0.4080, p = .0012, power = 0.9050). These results indicate that relative net vertical impulse can be used to assess vertical jump performance, regardless of initial squat depth, and that peak force may not be the best measure to assess vertical jump performance.

  2. The effect of patient age on bone formation using a fully synthetic nanocrystalline bone augmentation material in maxillary sinus grafting.

    PubMed

    Wolf, Michael; Wurm, Alexander; Heinemann, Friedhelm; Gerber, Thomas; Reichert, Christoph; Jäger, Andreas; Götz, Werner

    2014-01-01

    Maxillary sinus floor augmentation is a treatment that has been proposed for patients in whom the alveolar bone height is insufficient. This procedure is commonly used in patients aged 40 to 70 years and older. However, little information exists whether the factor of age might influence the outcome of augmentation procedures. The aim of this study was to investigate whether the patient's age has an effect on bone formation and incorporation in maxillary sinus floor augmentation procedures. A fully synthetic nanocrystalline bone augmentation material (NanoBone, Artoss) was used for sinus floor augmentation in patients with a subantral vertical bone height of at least 3 mm and maximum of 7 mm. After 7 months healing time, biopsy specimens were taken and were divided into two groups according to the patient's age. Exclusion criteria were poor general health (eg, severe renal/and or liver disease), history of a radiotherapy in the head region, chemotherapy at the time of surgical procedure, noncompensated diabetes mellitus, symptoms of a maxillary sinus disease, active periodontal or systemic diseases, smoking, and poor oral hygiene. Histologic analyses with hematoxylin-eosin stain were performed. Multinucleated osteoclast-like cells were identified by histochemical staining (tartrate-resistant acid phosphatase [TRAP]). Quantitative and age-dependent assessment of bone formation, residual bone grafting material, and soft tissue formation following sinus augmentation was performed using histomorphometric analysis and the Bonferroni adjustment of the Student t test. Twenty biopsy specimens from 17 patients were taken and divided into two groups according to age (group 1: 41 to 52 years; group 2: 66 to 71 years) containing 10 specimens each, which were analyzed in triplicate resulting in a total of 30 specimens per group. A regeneration process with varying amounts of newly formed bone surrounded by marrow-like tissue was present in all augmented regions. No signs of inflammation or immune reactions were visible. Residual particles of the augmentation material could be observed within the specimens. An age-dependent difference in investigated parameters between the two age groups could not be documented. The histologic examinations confirm that the fully synthetic nanocrystalline bone augmentation material used in this study is biocompatible and allows maxillary sinus augmentation in patients aged 41 to 70 years.

  3. Unification of height systems in the frame of GGOS

    NASA Astrophysics Data System (ADS)

    Sánchez, Laura

    2015-04-01

    Most of the existing vertical reference systems do not fulfil the accuracy requirements of modern Geodesy. They refer to local sea surface levels, are stationary (do not consider variations in time), realize different physical height types (orthometric, normal, normal-orthometric, etc.), and their combination in a global frame presents uncertainties at the metre level. To provide a precise geodetic infrastructure for monitoring the Earth system, the Global Geodetic Observing System (GGOS) of the International Association of Geodesy (IAG), promotes the standardization of the height systems worldwide. The main purpose is to establish a global gravity field-related vertical reference system that (1) supports a highly-precise (at cm-level) combination of physical and geometric heights worldwide, (2) allows the unification of all existing local height datums, and (3) guarantees vertical coordinates with global consistency (the same accuracy everywhere) and long-term stability (the same order of accuracy at any time). Under this umbrella, the present contribution concentrates on the definition and realization of a conventional global vertical reference system; the standardization of the geodetic data referring to the existing height systems; and the formulation of appropriate strategies for the precise transformation of the local height datums into the global vertical reference system. The proposed vertical reference system is based on two components: a geometric component consisting of ellipsoidal heights as coordinates and a level ellipsoid as the reference surface, and a physical component comprising geopotential numbers as coordinates and an equipotential surface defined by a conventional W0 value as the reference surface. The definition of the physical component is based on potential parameters in order to provide reference to any type of physical heights (normal, orthometric, etc.). The conversion of geopotential numbers into metric heights and the modelling of the reference surface (geoid or quasigeoid determination) are considered as steps of the realization. The vertical datum unification strategy is based on (1) the physical connection of height datums to determine their discrepancies, (2) joint analysis of satellite altimetry and tide gauge records to determine time variations of sea level at reference tide gauges, (3) combination of geometrical and physical heights in a well-distributed and high-precise reference frame to estimate the relationship between the individual vertical levels and the global one, and (4) analysis of GNSS time series at reference tide gauges to separate crustal movements from sea level changes. The final vertical transformation parameters are provided by the common adjustment of the observation equations derived from these methods.

  4. Analysis of socket preservation using polylactide and polyglycolide (PLA-PGA) sponge: a clinical, radiographic, and histologic study.

    PubMed

    Madan, Rohit; Mohan, Ranjana; Bains, Vivek K; Gupta, Vivek; Singh, G P; Madan, Mani

    2014-01-01

    The aim of this study was to evaluate the extraction socket healing and dimensional changes following alveolar ridge preservation using polylactide and polyglycolide (PLA-PGA) sponge. Fifteen patients were selected for alveolar socket preservation immediately following tooth extraction. Monoradicular maxillary and mandibular teeth were evaluated. The selected sockets had intact sockets walls with a minimum of 7 mm of residual alveolar bone height. The test sites were thoroughly debrided and grafted with PLA-PGA sponge, while the control sites underwent natural healing. Computed tomography (CT) measurements were taken at baseline and 6 months. After 6 months of healing, final CT measurements were performed, and trephine core biopsy specimens were obtained for histologic analysis. Implants were placed immediately after biopsy harvesting. All subjects completed the study, and all sites healed without adverse events and allowed for implant placement. The mean difference in socket height, width, and density after 6 months was statistically significantly higher in the test sites compared with control sites. Clinical measurement at the midbuccal site of the alveolar socket showed a mean loss of 2.45 ± 0.67 mm in the control group, compared with a mean gain of 1.28 ± 0.58 mm in the test group. All test sites showed minimal ridge alterations, and statistically significant differences were observed between the test and control sites with respect to bone composition and horizontal and vertical bone loss, indicating that PLA-PGA sponge is suitable for alveolar ridge preservation.

  5. Relative stability of deep- versus shallow-side bone levels in angular proximal infrabony defects.

    PubMed

    Heins, P; Hartigan, M; Low, S; Chace, R

    1989-01-01

    The relative changes with time, in the position of the coronal margin of the mesial and distal bone of proximal, angular infrabony defects, were investigated. Tracings of the radiographs of 51 mandibular posterior sites, treated by flap curettage, with a mean post-surgical duration of 11.8 years, were measured using a digitizer pad. The group consisting of shallow-side sites (N = 51), exhibited no significant change in the bone height with time; however, there was a significant decrease in bone height in the deep-side group (N = 51). The mean area of proximal bone decreased significantly with time. The defects were divided into early (N = 25) and advanced (N = 26) angular groups, and then into deep- and shallow-side subgroups. In the early defect group, there was a significant decrease in the mean bone height of the deep-side subgroup. There were no differences in the changes of mean bone level of the remaining 3 subgroups with time. There was no correlation between changes in bone levels of adjacent mesial and distal sides of angular defects with time (r = 0.27). There was no difference between the deep- and shallow-side groups in the number of sites which gained, lost or evidenced no change in bone height. In the study population, the bone height of 73% of the deep-side, and 84% of the shallow-side sites was either unchanged or in a more coronal position.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Influence of biphasic calcium phosphate surfaces coated with Enamel Matrix Derivative on vertical bone growth in an extra-oral rabbit model.

    PubMed

    Wen, Bo; Li, Zhen; Nie, Rongrong; Liu, Chao; Zhang, Peng; Miron, Richard J; Dard, Michel M

    2016-10-01

    The aim of this study was to investigate the ability of Enamel Matrix Derivative (EMD) on vertical bone regeneration around dental implants placed in an extra-oral rabbit model. A total of 30 Straumann BL implants were partially embedded in transverse orientation into the posterior mandibles of 15 rabbits. Macro-structuring BiPhasicCaPST (BCPT1), micro-structuring BiPhasicCaPST (BCPT2), and deproteinized bovine bone mineral (DBBM) were placed around the implant and covered with a scaffold stabilizing "umbrella." EMD was incorporated within the scaffold for test sites, but not control sites. Histological analysis was performed on retrieved specimens after 10 weeks of healing to assess new bone formation. All treatment groups displayed new supracrestal bone formation as determined by histomorphometric measurements, with mean values of new bone height ranging between 0.62 and 1.13 mm. Histological analysis revealed a higher mean bone formation (%) around the test sites where EMD (34.7, 95%CI: 27.1-39.4) was released from the scaffold, whereas the control group without EMD release (26.4, 95%CI: 16.3-31.9) (P = 0.069). The mean fBIC (%) in the BCPT2 group increased by the addition of EMD relative to no EMD (67.2, 95%CI: 48.6-84.1) and (54.7, 95%CI: 32.3-68.9), respectively). The BCPT2/EMD and DBBM/EMD interventions showed the greatest mean bone density (BA/TA), respectively, (12.8, 95%CI: 8.9-36.5) and (11.2, 6.3-16.4) in ROI 1. Values in ROI 2 were, similarly, (24.9, 95%CI: 17.2-31.7) and (27.7, 19.2-35.3). BA/TA in ROI 2 differences between the BCPT2 groups with and without EMD was statistically significant (P = 0.026), as well as the DBBM groups with and without EMD (P = 0.038). A layer of new bone was formed in both test and controls. The release of EMD from BCPT2 and DBBM adjacent to a bone-level implant with an SLActive surface and scaffold retention umbrella consistently regenerated the greater fBIC and bone density along the length of the implant. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Vertical Jump Height Estimation Algorithm Based on Takeoff and Landing Identification Via Foot-Worn Inertial Sensing.

    PubMed

    Wang, Jianren; Xu, Junkai; Shull, Peter B

    2018-03-01

    Vertical jump height is widely used for assessing motor development, functional ability, and motor capacity. Traditional methods for estimating vertical jump height rely on force plates or optical marker-based motion capture systems limiting assessment to people with access to specialized laboratories. Current wearable designs need to be attached to the skin or strapped to an appendage which can potentially be uncomfortable and inconvenient to use. This paper presents a novel algorithm for estimating vertical jump height based on foot-worn inertial sensors. Twenty healthy subjects performed countermovement jumping trials and maximum jump height was determined via inertial sensors located above the toe and under the heel and was compared with the gold standard maximum jump height estimation via optical marker-based motion capture. Average vertical jump height estimation errors from inertial sensing at the toe and heel were -2.2±2.1 cm and -0.4±3.8 cm, respectively. Vertical jump height estimation with the presented algorithm via inertial sensing showed excellent reliability at the toe (ICC(2,1)=0.98) and heel (ICC(2,1)=0.97). There was no significant bias in the inertial sensing at the toe, but proportional bias (b=1.22) and fixed bias (a=-10.23cm) were detected in inertial sensing at the heel. These results indicate that the presented algorithm could be applied to foot-worn inertial sensors to estimate maximum jump height enabling assessment outside of traditional laboratory settings, and to avoid bias errors, the toe may be a more suitable location for inertial sensor placement than the heel.

  8. Validity and reliability of Optojump photoelectric cells for estimating vertical jump height.

    PubMed

    Glatthorn, Julia F; Gouge, Sylvain; Nussbaumer, Silvio; Stauffacher, Simone; Impellizzeri, Franco M; Maffiuletti, Nicola A

    2011-02-01

    Vertical jump is one of the most prevalent acts performed in several sport activities. It is therefore important to ensure that the measurements of vertical jump height made as a part of research or athlete support work have adequate validity and reliability. The aim of this study was to evaluate concurrent validity and reliability of the Optojump photocell system (Microgate, Bolzano, Italy) with force plate measurements for estimating vertical jump height. Twenty subjects were asked to perform maximal squat jumps and countermovement jumps, and flight time-derived jump heights obtained by the force plate were compared with those provided by Optojump, to examine its concurrent (criterion-related) validity (study 1). Twenty other subjects completed the same jump series on 2 different occasions (separated by 1 week), and jump heights of session 1 were compared with session 2, to investigate test-retest reliability of the Optojump system (study 2). Intraclass correlation coefficients (ICCs) for validity were very high (0.997-0.998), even if a systematic difference was consistently observed between force plate and Optojump (-1.06 cm; p < 0.001). Test-retest reliability of the Optojump system was excellent, with ICCs ranging from 0.982 to 0.989, low coefficients of variation (2.7%), and low random errors (±2.81 cm). The Optojump photocell system demonstrated strong concurrent validity and excellent test-retest reliability for the estimation of vertical jump height. We propose the following equation that allows force plate and Optojump results to be used interchangeably: force plate jump height (cm) = 1.02 × Optojump jump height + 0.29. In conclusion, the use of Optojump photoelectric cells is legitimate for field-based assessments of vertical jump height.

  9. Scaling of human body composition to stature: new insights into body mass index.

    PubMed

    Heymsfield, Steven B; Gallagher, Dympna; Mayer, Laurel; Beetsch, Joel; Pietrobelli, Angelo

    2007-07-01

    Although Quetelet first reported in 1835 that adult weight scales to the square of stature, limited or no information is available on how anatomical body compartments, including adipose tissue (AT), scale to height. We examined the critical underlying assumptions of adiposity-body mass index (BMI) relations and extended these analyses to major anatomical compartments: skeletal muscle (SM), bone, residual mass, weight (AT+SM+bone), AT-free mass, and organs (liver, brain). This was a cross-sectional analysis of 2 body-composition databases: one including magnetic resonance imaging and dual-energy X-ray absorptiometry (DXA) estimates of evaluated components in adults (total n=411; organs=76) and the other a larger DXA database (n=1346) that included related estimates of fat, fat-free mass, and bone mineral mass. Weight, primary lean components (SM, residual mass, AT-free mass, and fat-free mass), and liver scaled to height with powers of approximately 2 (all P<0.001); bone and bone mineral mass scaled to height with powers >2 (2.31-2.48), and the fraction of weight as bone mineral mass was significantly (P<0.001) correlated with height in women. AT scaled weakly to height with powers of approximately 2, and adiposity was independent of height. Brain mass scaled to height with a power of 0.83 (P=0.04) in men and nonsignificantly in women; the fraction of weight as brain was inversely related to height in women (P=0.002). These observations suggest that short and tall subjects with equivalent BMIs have similar but not identical body composition, provide new insights into earlier BMI-related observations and thus establish a foundation for height-normalized indexes, and create an analytic framework for future studies.

  10. Scaling of human body composition to stature: new insights into body mass index 123

    PubMed Central

    Heymsfield, Steven B; Gallagher, Dympna; Mayer, Laurel; Beetsch, Joel; Pietrobelli, Angelo

    2009-01-01

    Background Although Quetelet first reported in 1835 that adult weight scales to the square of stature, limited or no information is available on how anatomical body compartments, including adipose tissue (AT), scale to height. Objective We examined the critical underlying assumptions of adiposity–body mass index (BMI) relations and extended these analyses to major anatomical compartments: skeletal muscle (SM), bone, residual mass, weight (AT+SM+bone), AT-free mass, and organs (liver, brain). Design This was a cross-sectional analysis of 2 body-composition databases: one including magnetic resonance imaging and dual-energy X-ray absorptiometry (DXA) estimates of evaluated components in adults (total n = 411; organs = 76) and the other a larger DXA database (n = 1346) that included related estimates of fat, fat-free mass, and bone mineral mass. Results Weight, primary lean components (SM, residual mass, AT-free mass, and fat-free mass), and liver scaled to height with powers of ≈2 (all P < 0.001); bone and bone mineral mass scaled to height with powers > 2 (2.31–2.48), and the fraction of weight as bone mineral mass was significantly (P < 0.001) correlated with height in women. AT scaled weakly to height with powers of ≈2, and adiposity was independent of height. Brain mass scaled to height with a power of 0.83 (P = 0.04) in men and nonsignificantly in women; the fraction of weight as brain was inversely related to height in women (P = 0.002). Conclusions These observations suggest that short and tall subjects with equivalent BMIs have similar but not identical body composition, provide new insights into earlier BMI-related observations and thus establish a foundation for height-normalized indexes, and create an analytic framework for future studies. PMID:17616766

  11. The addition of stripes (a version of the 'horizontal-vertical illusion') increases foot clearance when crossing low-height obstacles.

    PubMed

    Foster, Richard J; Buckley, John G; Whitaker, David; Elliott, David B

    2016-07-01

    Trips over obstacles are one of the main causes of falling in older adults, with vision playing an important role in successful obstacle negotiation. We determined whether a horizontal-vertical illusion, superimposed onto low-height obstacles to create a perceived increase in obstacle height, increased foot clearances during obstacle negotiation thus reducing the likelihood of tripping. Eleven adults (mean ± 1 SD: age 27.3 ± 5.1 years) negotiated obstacles of varying heights (3, 5, 7 cm) with four different appearance conditions; two were obstacles with a horizontal-vertical illusion (vertical stripes of different thickness) superimposed on the front, one was a plain obstacle and the fourth a plain obstacle with a horizontal black line painted on the top edge. Foot clearance parameters were compared across conditions. Both illusions led to a significant increase in foot clearance when crossing the obstacle, compared to the plain condition, irrespective of obstacle height. Superimposing a horizontal-vertical illusion onto low-height obstacles can increase foot clearance, and its use on the floor section of a double-glazing door frame for example may reduce the incidence of tripping in the home. Practitioner Summary: Low-height obstacles such as the floor section of a double-glazing door frame are potential tripping hazards. In a gait lab-based study we found that a horizontal-vertical illusion superimposed onto low-height obstacles led to significantly higher foot clearances; indicating their potential as a useful safety measure.

  12. Prediction of Vertical Jump Height from Anthropometric Factors in Male and Female Martial Arts Athletes

    PubMed Central

    Abidin, Nahdiya Zainal; Adam, Mohd Bakri

    2013-01-01

    Background: Vertical jump is an index representing leg/kick power. The explosive movement of the kick is the key to scoring in martial arts competitions. It is important to determine factors that influence the vertical jump to help athletes improve their leg power. The objective of the present study is to identify anthropometric factors that influence vertical jump height for male and female martial arts athletes. Methods: Twenty-nine male and 25 female athletes participated in this study. Participants were Malaysian undergraduate students whose ages ranged from 18 to 24 years old. Their heights were measured using a stadiometer. The subjects were weighted using digital scale. Body mass index was calculated by kg/m2. Waist–hip ratio was measured from the ratio of waist to hip circumferences. Body fat % was obtained from the sum of four skinfold thickness using Harpenden callipers. The highest vertical jump from a stationary standing position was recorded. The maximum grip was recorded using a dynamometer. For standing back strength, the maximum pull upwards using a handle bar was recorded. Multiple linear regression was used to obtain the relationship between vertical jump height and explanatory variables with gender effect. Results: Body fat % has a significant negative relationship with vertical jump height (P < 0.001). The effect of gender is significant (P < 0.001): on average, males jumped 26% higher than females did. Conclusion: Vertical jump height of martial arts athletes can be predicted by body fat %. The vertical jump for male is higher than for their female counterparts. Reducing body fat by proper dietary planning will help to improve leg power. PMID:23785254

  13. Vertical Ridge Augmentation and Soft Tissue Reconstruction of the Anterior Atrophic Maxillae: A Case Series.

    PubMed

    Urban, Istvan A; Monje, Alberto; Wang, Hom-Lay

    2015-01-01

    Severe vertical ridge deficiency in the anterior maxilla represents one of the most challenging clinical scenarios in the bone regeneration arena. As such, a combination of vertical bone augmentation using various biomaterials and soft tissue manipulation is needed to obtain successful outcomes. The present case series describes a novel approach to overcome vertical deficiencies in the anterior atrophied maxillae by using a mixture of autologous and anorganic bovine bone. Soft tissue manipulation including, but not limited to, free soft tissue graft was used to overcome the drawbacks of vertical bone augmentation (eg, loss of vestibular depth and keratinized mucosa). By combining soft and hard tissue grafts, optimum esthetic and long-term implant prosthesis stability can be achieved and sustained.

  14. Secondary Alveolar Bone Grafting in Patients Born With Unilateral Cleft Lip and Palate: A 20-Year Follow-up.

    PubMed

    Jabbari, Fatemeh; Wiklander, Laila; Reiser, Erika; Thor, Andreas; Hakelius, Malin; Nowinski, Daniel

    2018-02-01

    To identify factors of oral health important for the final outcome, after secondary alveolar bone grafting in patients born with unilateral cleft lip and palate and compare occlusal radiographs with cone beam computed tomography (CBCT) in assessment of alveolar bone height. Observational follow-up study. Cleft Lip and Palate Team, Craniofacial Center, Uppsala University Hospital, Sweden. 40 nonsyndromic, Caucasian patients with unilateral complete cleft lip and palate. Clinical examination, CBCT, and occlusal radiographs. Alveolar bone height was evaluated according to Bergland index at a 20-year follow-up. The alveolar bone height in the cleft area was significantly reduced compared to a previously reported 10-year follow-up in the same cohort by total ( P = .045) and by subgroup with dental restoration ( P = .0078). This was positively correlated with the gingival bleeding index (GBI) ( r = 0.51, P = .0008) and presence of dental restorations in the cleft area ( r = 0.45, P = .0170). There was no difference in the Bergland index generated from scoring the alveolar bone height on occlusal radiographs as with the equivalent index on CBCT. Patients rehabilitated with complex dental restoration seems to be at higher risk for progression of bone loss in the cleft area. Supportive periodontal therapy should be implemented after complex dental restorations in cleft patients. Conventional occlusal radiographs provide an adequate image for evaluating postoperative bone height in clinical follow-up.

  15. Conceptions of Height and Verticality in the History of Skyscrapers and Skylines

    NASA Astrophysics Data System (ADS)

    Maslovskaya, Oksana; Ignatov, Grigoriy

    2018-03-01

    The main goal of this article is to reveal the significance of height and verticality history of skyscrapers and skylines. The objectives are as follows: 1. trace the origin of design concepts related to skyscraper; 2. discuss the perceived experience of the cultural aspects of skyscrapers and skylines; 3. describe the differences and similarities of the profiles of with comparable skylines. The methodology of study is designed to explore the perceived theory and principals of skyscraper and skyline development phenomenon and its key features. The skyscraper reveals an assertive creative form of vertical design. Skyscraper construction also relates to the origin of ancient cultural symbolism as the dominant vertical element as the main features of an ordered space. The historical idea of height reaches back to the earliest civilization such as the Tower of Babel. Philosophical approaches of elements of such post-structuralism have been included in studying of skyscraper phenomenon. The analysis of skyscraper and their resulting skyline are examined to show the connection to their origins with their concepts of height and verticality. From the historical perspective, cities with skyscrapers and a skyline turn out to be an assertive manifestation of common ideas of height and verticality.

  16. Influence of lumbar spine extension on vertical jump height during maximal squat jumping.

    PubMed

    Blache, Yoann; Monteil, Karine

    2014-01-01

    The purpose of this study was to determine the influence of lumbar spine extension and erector spinae muscle activation on vertical jump height during maximal squat jumping. Eight male athletes performed maximal squat jumps. Electromyograms of the erector spinae were recorded during these jumps. A simulation model of the musculoskeletal system was used to simulate maximal squat jumping with and without spine extension. The effect on vertical jump height of changing erector spinae strength was also tested through the simulated jumps. Concerning the participant jumps, the kinematics indicated a spine extension and erector spinae activation. Concerning the simulated jumps, vertical jump height was about 5.4 cm lower during squat jump without trunk extension compared to squat jump. These results were explained by greater total muscle work during squat jump, more especially by the erector spinae work (+119.5 J). The erector spinae may contribute to spine extension during maximal squat jumping. The simulated jumps confirmed this hypothesis showing that vertical jumping was decreased if this muscle was not taken into consideration in the model. Therefore it is concluded that the erector spinae should be considered as a trunk extensor, which enables to enhance total muscle work and consequently vertical jump height.

  17. Is adaptation to perceived interocular differences in height explained by vertical fusional eye movements?

    PubMed

    Maier, Felix M; Schaeffel, Frank

    2013-07-24

    To find out whether adaptation to a vertical prism involves more than fusional vertical eye movements. Adaptation to a vertical base-up 3 prism diopter prism was measured in a custom-programmed Maddox test in nine visually normal emmetropic subjects (mean age 27.0 ± 2.8 years). Vertical eye movements were binocularly measured in six of the subjects with a custom-programmed binocular video eye tracker. In the Maddox test, some subjects adjusted the perceived height as expected from the power of the prism while others appeared to ignore the prism. After 15 minutes of adaptation, the interocular difference in perceived height was reduced by on average 51% (from 0.86°-0.44°). The larger the initially perceived difference in height in a subject, the larger the amplitude of adaptation was. Eye tracking showed that the prism generated divergent vertical eye movements of 1.2° on average, which was less than expected from its power. Differences in eye elevation were maintained as long as the prism was in place. Small angles of lateral head tilt generated large interocular differences in eye elevation, much larger than the effects introduced by the prism. Vertical differences in retinal image height were compensated by vertical fusional eye movements but some subjects responded poorly to a vertical prism in both experiments; fusional eye movements were generally too small to realign both foveae with the fixation target; and the prism adaptation in the Maddox test was fully explained by the changes in vertical eye position, suggesting that no further adaptational mechanism may be involved.

  18. Computerized tomography-assisted calculation of sinus augmentation volume.

    PubMed

    Krennmair, Gerald; Krainhöfner, Martin; Maier, Harald; Weinländer, Michael; Piehslinger, Eva

    2006-01-01

    This study was intended to calculate the augmentation volume for a sinus lift procedure based on cross-sectional computerized tomography (CT) scans for 2 different augmentation heights. Based on area calculations of cross-sectional CT scans, the volume of additional bone needed was calculated for 44 sinus lift procedures. The amount of bone volume needed to raise the sinus floor to heights of both 12 and 17 mm was calculated. To achieve a sinus floor height of 12 mm, it was necessary to increase the height by a mean of 7.2+/-2.1 mm (range, 3.0 to 10.5 mm), depending on the residual ridge height; to achieve a height of 17 mm, a mean of 12.4+/-2.0 mm (range, 8.5 to 15.5 mm) was required (P < .01). The calculated augmentation volume for an augmentation height of 12 mm was 1.7+/-.9 cm3; for an augmentation height of 17 mm, the volume required was 3.6+/-1.5 cm3. Increasing the height of the sinus lift by 5 mm, ie, from 12 mm to 17 mm augmentation height, increased the augmentation volume by 100%. A significant correlation was found between augmentation height and the calculated sinus lift augmentation volume (r = 0. 78, P < .01). Detailed preoperative knowledge of sinus lift augmentation volume is helpful as a predictive value in deciding on a donor site for harvesting autogenous bone and on the ratio of bone to bone substitute to use. Calculation of the augmentation size can help determine the surgical approach and thus perioperative treatment and the costs of the surgery for both patients and clinicians.

  19. Optimum Drop Jump Height in Division III Athletes: Under 75% of Vertical Jump Height.

    PubMed

    Peng, Hsien-Te; Khuat, Cong Toai; Kernozek, Thomas W; Wallace, Brian J; Lo, Shin-Liang; Song, Chen-Yi

    2017-10-01

    Our purpose was to evaluate the vertical ground reaction force, impulse, moments and powers of hip, knee and ankle joints, contact time, and jump height when performing a drop jump from different drop heights based on the percentage of a performer's maximum vertical jump height (MVJH). Fifteen male Division III athletes participated voluntarily. Eleven synchronized cameras and two force platforms were used to collect data. One-way repeated-measures analysis of variance tests were used to examine the differences between drop heights. The maximum hip, knee and ankle power absorption during 125%MVJH and 150%MVJH were greater than those during 75%MVJH. The impulse during landing at 100%MVJH, 125%MVJH and 150%MVJH were greater than 75%MVJH. The vertical ground reaction force during 150%MVJH was greater than 50%MVJH, 75%MVJH and 100%MVJH. Drop height below 75%MVJH had the most merits for increasing joint power output while having a lower impact force, impulse and joint power absorption. Drop height of 150%MVJH may not be desirable as a high-intensity stimulus due to the much greater impact force, increasing the risk of injury, without increasing jump height performance. © Georg Thieme Verlag KG Stuttgart · New York.

  20. The functional muscle-bone unit in children with cerebral palsy.

    PubMed

    Duran, I; Schütz, F; Hamacher, S; Semler, O; Stark, C; Schulze, J; Rittweger, J; Schoenau, E

    2017-07-01

    Our results suggest that the prevalence of bone health deficits in children with CP was overestimated, when using only age- and height-adjusted bone mineral content (BMC) and areal bone mineral density (aBMD). When applying the functional muscle-bone unit diagnostic algorithm (FMBU-A), the prevalence of positive results decreased significantly. We recommend applying the FMBU-A when assessing bone health in children with CP. The prevalence of bone health deficits in children with cerebral palsy (CP) might be overestimated because age- and height-adjusted reference percentiles for bone mineral content (BMC) and areal bone mineral density (aBMD) assessed by dual-energy X-ray absorptiometry (DXA) do not consider reduced muscle activity. The aim of this study was to compare the prevalence of positive DXA-based indicators for bone health deficits in children with CP to the prevalence of positive findings after applying a functional muscle-bone unit diagnostic algorithm (FMBU-A) considering reduced muscle activity. The present study was a monocentric retrospective analysis of 297 whole body DXA scans of children with CP. The prevalence of positive results of age- and height-adjusted BMC and aBMD defined as BMC and aBMD below the P3 percentile and of the FMBU-A was calculated. In children with CP, the prevalence of positive results of age-adjusted BMC were 33.3% and of aBMD 50.8%. Height-adjusted results for BMC and aBMD were positive in 16.8 and 36.0% of cases. The prevalence of positive results applying the FMBU-A regarding BMC and aBMD were significantly (p < 0.001) lower than using age- and height-adjusted BMC and aBMD (8.8 and 14.8%). Our results suggest that the prevalence of bone health deficits in children with CP was overestimated, when using age- and height-adjusted BMC and aBMD. When applying the FMBU-A, the prevalence decreased significantly. We recommend applying the FMBU-A when assessing bone health in children with CP.

  1. The concurrent validity and reliability of a low-cost, high-speed camera-based method for measuring the flight time of vertical jumps.

    PubMed

    Balsalobre-Fernández, Carlos; Tejero-González, Carlos M; del Campo-Vecino, Juan; Bavaresco, Nicolás

    2014-02-01

    Flight time is the most accurate and frequently used variable when assessing the height of vertical jumps. The purpose of this study was to analyze the validity and reliability of an alternative method (i.e., the HSC-Kinovea method) for measuring the flight time and height of vertical jumping using a low-cost high-speed Casio Exilim FH-25 camera (HSC). To this end, 25 subjects performed a total of 125 vertical jumps on an infrared (IR) platform while simultaneously being recorded with a HSC at 240 fps. Subsequently, 2 observers with no experience in video analysis analyzed the 125 videos independently using the open-license Kinovea 0.8.15 software. The flight times obtained were then converted into vertical jump heights, and the intraclass correlation coefficient (ICC), Bland-Altman plot, and Pearson correlation coefficient were calculated for those variables. The results showed a perfect correlation agreement (ICC = 1, p < 0.0001) between both observers' measurements of flight time and jump height and a highly reliable agreement (ICC = 0.997, p < 0.0001) between the observers' measurements of flight time and jump height using the HSC-Kinovea method and those obtained using the IR system, thus explaining 99.5% (p < 0.0001) of the differences (shared variance) obtained using the IR platform. As a result, besides requiring no previous experience in the use of this technology, the HSC-Kinovea method can be considered to provide similarly valid and reliable measurements of flight time and vertical jump height as more expensive equipment (i.e., IR). As such, coaches from many sports could use the HSC-Kinovea method to measure the flight time and height of their athlete's vertical jumps.

  2. Marginal bone level changes in association with different vertical implant positions: a 3-year retrospective study

    PubMed Central

    2017-01-01

    Purpose To retrospectively evaluate the relationship between the vertical position of the implant-abutment interface and marginal bone loss over 3 years using radiological analysis. Methods In total, 286 implant surfaces of 143 implants from 61 patients were analyzed. Panoramic radiographic images were taken immediately after implant installation and at 6, 12, and 36 months after loading. The implants were classified into 3 groups based on the vertical position of the implant-abutment interface: group A (above bone level), group B (at bone level), and group C (below bone level). The radiographs were analyzed by a single examiner. Results Changes in marginal bone levels of 0.99±1.45, 1.13±0.91, and 1.76±0.78 mm were observed at 36 months after loading in groups A, B, and C, respectively, and bone loss was significantly greater in group C than in groups A and B. Conclusions The vertical position of the implant-abutment interface may affect marginal bone level change. Marginal bone loss was significantly greater in cases where the implant-abutment interface was positioned below the marginal bone. Further long-term study is required to validate our results. PMID:28861287

  3. Increase in Jumping Height Associated with Maximal Effort Vertical Depth Jumps.

    ERIC Educational Resources Information Center

    Bedi, John F.; And Others

    1987-01-01

    In order to assess if there existed a statistically significant increase in jumping performance when dropping from different heights, 32 males, aged 19 to 26, performed a series of maximal effort vertical jumps after dropping from eight heights onto a force plate. Results are analyzed. (Author/MT)

  4. Effects of short-term two weeks low intensity plyometrics combined with dynamic stretching training in improving vertical jump height and agility on trained basketball players.

    PubMed

    Ramachandran, Selvam; Pradhan, Binita

    2014-01-01

    Sport specific training in basketball players should focus on vertical jump height and agility in consistent with demands of the sport. Since plyometrics training improves vertical jump height and agility, it can be useful training strategy to improve the performance of basketball players. A convenience sample of thirty professional basketball players were recruited. Following pre-intervention assessment, interventions using plyometrics training and dynamic stretching protocol was administered on the basketball players. The outcome measures were assessed before the intervention and at the end of first and second week. Statistically significant improvements in vertical jump height (31.68 ± 11.64 to 37.57 ± 16.74; P < 0.012) and agility (16.75 ± 2.49 to 16.51 ± 2.80; P <0.00) were observed between pretest--posttest measures and no changes in muscle girth and isometric muscle strength. The study concludes that short term two weeks plyometrics training combined with dynamic stretching as a useful sport specific training strategy to improve vertical jump height and agility on trained basketball players.

  5. Simulation of ICESat-2 canopy height retrievals for different ecosystems

    NASA Astrophysics Data System (ADS)

    Neuenschwander, A. L.

    2016-12-01

    Slated for launch in late 2017 (or early 2018), the ICESat-2 satellite will provide a global distribution of geodetic measurements from a space-based laser altimeter of both the terrain surface and relative canopy heights which will provide a significant benefit to society through a variety of applications ranging from improved global digital terrain models to producing distribution of above ground vegetation structure. The ATLAS instrument designed for ICESat-2, will utilize a different technology than what is found on most laser mapping systems. The photon counting technology of the ATLAS instrument onboard ICESat-2 will record the arrival time associated with a single photon detection. That detection can occur anywhere within the vertical distribution of the reflected signal, that is, anywhere within the vertical distribution of the canopy. This uncertainty of where the photon will be returned from within the vegetation layer is referred to as the vertical sampling error. Preliminary simulation studies to estimate vertical sampling error have been conducted for several ecosystems including woodland savanna, montane conifers, temperate hardwoods, tropical forest, and boreal forest. The results from these simulations indicate that the canopy heights reported on the ATL08 data product will underestimate the top canopy height in the range of 1 - 4 m. Although simulation results indicate the ICESat-2 will underestimate top canopy height, there is, however, a strong correlation between ICESat-2 heights and relative canopy height metrics (e.g. RH75, RH90). In tropical forest, simulation results indicate the ICESat-2 height correlates strongly with RH90. Similarly, in temperate broadleaf forest, the simulated ICESat-2 heights were also strongly correlated with RH90. In boreal forest, the simulated ICESat-2 heights are strongly correlated with RH75 heights. It is hypothesized that the correlations between simulated ICESat-2 heights and canopy height metrics are a function of both canopy cover and vegetation physiology (e.g. leaf size/shape) which contributes to the horizontal and vertical structure of the vegetation.

  6. The effect of cigarette smoking and native bone height on dental implants placed immediately in sinuses grafted by hydraulic condensation.

    PubMed

    Lin, Thomas H S; Chen, Leon; Cha, Jennifer; Jeffcoat, Marjorie; Kao, Daniel W K; Nevins, Myron; Fiorellini, Joseph P

    2012-06-01

    The purpose of this study was to determine the effect of cigarette smoking and residual native bone height on the survival of dental implants placed immediately in grafted sinuses. In this retrospective study, 334 subject records were screened, and 75 subjects (155 implants) were included. Data collection based on treatment notes and radiographs included age, sex, smoking status, sinus floor bone height, dental implant information, and implant survival. The survival rates of implants for nonsmokers and smokers at stage-two surgery were 93% and 84%, respectively. After 12 months of functional loading, the survival rates of implants for nonsmokers and smokers were 87% (81 of 93) and 79% (49 of 62), respectively (P < .000). Analysis revealed that the effect of smoking on implant survival is significant when the preoperative bone height is less than 4 mm, with an 82.4% implant survival rate in nonsmokers compared to 60% in smokers (P < .05). Smoking should be considered as a high risk factor when implants are placed immediately in grafted sinuses, particularly in areas of limited bone height.

  7. Validity of height loss as a predictor for prevalent vertebral fractures, low bone mineral density, and vitamin D deficiency.

    PubMed

    Mikula, A L; Hetzel, S J; Binkley, N; Anderson, P A

    2017-05-01

    Many osteoporosis-related vertebral fractures are unappreciated but their detection is important as their presence increases future fracture risk. We found height loss is a useful tool in detecting patients with vertebral fractures, low bone mineral density, and vitamin D deficiency which may lead to improvements in patient care. This study aimed to determine if/how height loss can be used to identify patients with vertebral fractures, low bone mineral density, and vitamin D deficiency. A hospital database search in which four patient groups including those with a diagnosis of osteoporosis-related vertebral fracture, osteoporosis, osteopenia, or vitamin D deficiency and a control group were evaluated for chart-documented height loss over an average 3 1/2 to 4-year time period. Data was retrieved from 66,021 patients (25,792 men and 40,229 women). A height loss of 1, 2, 3, and 4 cm had a sensitivity of 42, 32, 19, and 14% in detecting vertebral fractures, respectively. Positive likelihood ratios for detecting vertebral fractures were 1.73, 2.35, and 2.89 at 2, 3, and 4 cm of height loss, respectively. Height loss had lower sensitivities and positive likelihood ratios for detecting low bone mineral density and vitamin D deficiency compared to vertebral fractures. Specificity of 1, 2, 3, and 4 cm of height loss was 70, 82, 92, and 95%, respectively. The odds ratios for a patient who loses 1 cm of height being in one of the four diagnostic groups compared to a patient who loses no height was higher for younger and male patients. This study demonstrated that prospective height loss is an effective tool to identify patients with vertebral fractures, low bone mineral density, and vitamin D deficiency although a lack of height loss does not rule out these diagnoses. If significant height loss is present, the high positive likelihood ratios support a further workup.

  8. Acute effects of unilateral whole body vibration training on single leg vertical jump height and symmetry in healthy men.

    PubMed

    Shin, Seungho; Lee, Kyeongjin; Song, Changho

    2015-12-01

    [Purpose] The aim of the present study was to investigate the acute effects of unilateral whole body vibration training on height and symmetry of the single leg vertical jump in healthy men. [Subjects] Thirty males with no history of lower limb dysfunction participated in this study. [Methods] The participants were randomly allocated to one of three groups: the unilateral vibratory stimulation group (n=10), bilateral vibratory stimulation group (n=10), and, no vibratory stimulation group (n=10). The subjects in the unilateral and bilateral stimulation groups participated in one session of whole body vibration training at 26 Hz for 3 min. The no vibratory stimulation group subjects underwent the same training for 3 min without whole body vibration. All participants performed the single leg vertical jump for each lower limb, to account for the strong and weak sides. The single leg vertical jump height and symmetry were measured before and after the intervention. [Results] The single leg vertical jump height of the weak lower limb significantly improved in the unilateral vibratory stimulation group, but not in the other groups. The single leg vertical jump height of the strong lower limb significantly improved in the bilateral vibratory stimulation group, but not in the other groups. The single leg vertical jump symmetry significantly improved in the unilateral vibratory stimulation group, but not in the other groups. [Conclusion] Therefore, the present study found that the effects of whole body vibration training were different depending on the type of application. To improve the single leg vertical jump height in the weak lower limbs as well as limb symmetry, unilateral vibratory stimulation might be more desirable.

  9. [Relationship between weight, body composition and bone mass in peritoneal dialysis].

    PubMed

    Negri, A L; Barone, R; Bogado, C E; Zanchetta, J R

    2005-01-01

    Patients in chronic dialysis show a decrease in total bone mass. The factors that determine this decrease are not well known. In normal populations weight and its compartments are important determinants of bone mass. We studied total bone mineral content (TBMC), a measure of bone mass, and body composition using DEXA densitometry in 65 patients (45 females and 20 males) who had been in peritoneal dialysis for a mean of 40.3 +/- 23.2 months. Forty-eight patients (73.8%) had been previously in hemodialysis. The mean total time in dialysis for these patients was 76.8 months. As a group patients showed a very significant positive correlation between TBMC and weight, height, and lean body mass. A negative correlation was found between TBMC with the time in dialysis and iPTH. In men we found significant simple positive correlations between TBMC and weight, height and lean body mass. In women we found simple positive correlations of TBMC with weight, height and lean body mass and a negative correlation with iPTH. In the multiple regression analysis, lean body mass was the only body composition parameter that had a significantly positive correlation with TBMC in men; in women only height correlated positively with TBMC and iPTH continued to correlate negatively with bone mass. When we considered pre and postmenopausal women separately, bone mass was correlated positively with height and lean body mass and negatively with iPTH in postmenopausal women and only with height in pre-menopausal females. We conclude that the lean body mass compartment. is the most important component of weight that determines TBMC in peritoneal dialysis patients particularly in males and postmenopausal women. In postmenopausal women, secondary hyperparathyroidism seems to be particularly detrimental on bone mass.

  10. Countermovement strategy changes with vertical jump height to accommodate feasible force constraints.

    PubMed

    Kim, Seyoung; Park, Sukyung; Choi, Sangkyu

    2014-09-22

    In this study, we developed a curve-fit model of countermovement dynamics and examined whether the characteristics of a countermovement jump can be quantified using the model parameter and its scaling; we expected that the model-based analysis would facilitate an understanding of the basic mechanisms of force reduction and propulsion with a simplified framework of the center of mass (CoM) mechanics. Ten healthy young subjects jumped straight up to five different levels ranging from approximately 10% to 35% of their body heights. The kinematic and kinetic data on the CoM were measured using a force plate system synchronized with motion capture cameras. All subjects generated larger vertical forces compared with their body weights from the countermovement and sufficiently lowered their CoM position to support the work performed by push-off as the vertical elevations became more challenging. The model simulation reasonably reproduced the trajectories of vertical force during the countermovement, and the model parameters were replaced by linear and polynomial regression functions in terms of the vertical jump height. Gradual scaling trends of the individual model parameters were observed as a function of the vertical jump height with different degrees of scaling, depending on the subject. The results imply that the subjects may be aware of the jumping dynamics when subjected to various vertical jump heights and may select their countermovement strategies to effectively accommodate biomechanical constraints, i.e., limited force generation for the standing vertical jump. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Predictive value of ridge dimensions on autologous bone graft resorption in staged maxillary sinus augmentation surgery using Cone-Beam CT.

    PubMed

    Klijn, R J; van den Beucken, J J J P; Bronkhorst, E M; Berge, S J; Meijer, G J; Jansen, J A

    2012-04-01

    No studies are available that provide predictive parameters regarding the expected amount of resorption after maxillary sinus augmentation surgery using autologous bone grafts. Therefore, the aim of this study was to determine parameters influencing the outcome of the bone graft resorption process. In 20 patients, three-dimensional analysis of alveolar ridge dimensions and bone graft volume change in the atrophic posterior maxilla was performed by Cone-Beam Computerized Tomography imaging. Ridge dimensions were assessed before maxillary sinus augmentation surgery. Bone graft volumes were compared after maxillary sinus floor augmentation surgery and a graft healing interval of several months. To analyze the relation between bone volume changes with the independent variables, patients' gender, age, alveolar crest height and width, and graft healing time interval, a multi-level extension of linear regression was applied. A residual bone height of 6.0 mm (SD = 3.6 mm) and 6.2 mm (SD = 3.6 mm) was found at the left and right sides, respectively. Moreover, alveolar bone widths of 6.5 mm (SD = 2.2 mm) and 7.0 mm (SD = 2.3 mm) at the premolars, and 8.8 mm (SD = 2.2 mm) and 8.9 mm (SD = 2.5 mm) at the molars regions were found at the left and right site, respectively. Bone graft volume decreased by 25.0% (SD = 21.0%) after 4.7 months (SD = 2.7, median = 4.0 months) of healing time. The variables "age" (P = 0.009) and mean alveolar crest "bone height" (P = 0.043), showed a significant influence on bone graft resorption. A decrease of 1.0% (SE = 0.3%) of bone graft resorption was found for each year the patient grew older, and an increase in bone graft resorption of 1.8% (SE = 0.8%) was found for each mm of original bone height before sinus floor augmentation. Graft resorption occurs when using autologous bone grafts for maxillary sinus augmentation. Alveolar crest bone height and patient age have a significant effect on graft resorption, with increased resorption for higher alveolar crest bone height and decreased resorption for older patients. Consequently, patient characteristics that affect the process of bone graft resorption should be given full consideration, when performing sinus augmentation surgery. © 2011 John Wiley & Sons A/S.

  12. Five-class height-weight model for systematization of seventeen-year-old recruits' anthropometric data.

    PubMed

    Lintsi, Mart; Kaarma, Helje

    2003-12-01

    An anthropometric study of 552 Tartu city and Tartu county recruits aged 17 years was carried out. Height and weight, 33 anthropometric measurements and 12 skinfolds were measured. Body fat percentage was assessed by Omron BF 300 hand-held segmental body fat analyzer. From anthropometric measurements bone mass was derived by the Drink-water et al. (1986) equation, and total skeletal muscle mass by the Lee et al. (2000) equation. The data were systematized into five height-weight SD-classes. There were 3 classes with harmony between height and weight class: 1--small (small height and small weight), 2--medium (medium height and medium weight), 3--large (large height and large weight), 4--weight class dominating (pyknomorphic) and 5--height class dominating (leptomorphic). It was revealed that in classes 1, 2 and 3 the height and weight increase corresponded to the increase in all heights, breadths and depths, circumferences, skinfolds, body fat, muscle and bone mass. In class 4 circumferences, skinfolds, body fat and muscle mass were bigger. In class 5 all heights and the relative bone mass were bigger. The present investigation confirms the hypothesis that the five height-weight class system is applicable to seventeen-year-old recruits.

  13. ABCD: Anthropometry, Body Composition, and Crohn Disease.

    PubMed

    Brookes, Denise S K; Briody, Julie N; Davies, Peter S W; Hill, Rebecca J

    2016-07-01

    Young individuals with Crohn disease (CD) are at risk of poor bone mineral density (BMD) and reduced lean tissue mass (LTM). The importance of LTM for maintaining skeletal health, in both incident and established CD, is evidenced. We used dual-energy x-ray absorptiometry assessment to identify areal BMD and LTM in individuals with CD. In 57 patients with CD (15F; 12.99-14.16 years) anthropometric, disease activity, bone age assessment, and total body dual-energy x-ray absorptiometry measurements were acquired. A 4-step algorithm was used to assess simultaneous bone and body composition data: areal BMD and height z scores, and LTM for height and bone mineral content (BMC) for LTM z scores were calculated. Low z score cut-off values were defined as ≤1 standard deviations below the population means. The CD cohort showed: low areal BMD z scores (P = 0.00); and low LTM for height (P = 0.00) according to defined cut-off values. BMC appeared to be adapting for the lower amount of LTM. Correcting for bone age eliminated the low areal BMD z scores. As expected, LTM for height and BMC for LTM z scores remained unchanged. We present a useful clinical algorithm to show significant LTM for height deficits, regardless of chronological or bone age, in this CD cohort. BMC seemed to adapt to the reduced LTM, indicating clinically "normal" areal BMD for age when considered for height. The ongoing deficits in LTM may, however, create chronic long-term consequences for bone health. Improving LTM should be a focus of clinical treatment in individuals with CD.

  14. The three dimensional distribution of chromium and nickel alloy welding fumes.

    PubMed

    Mori, T; Matsuda, A; Akashi, S; Ogata, M; Takeoka, K; Yoshinaka, M

    1991-08-01

    In the present study, the fumes generated from manual metal arc (MMA) and submerged metal arc (SMA) welding of low temperature service steel, and the chromium and nickel percentages in these fumes, were measured at various horizontal distances and vertical heights from the arc in order to obtain a three dimensional distribution. The MMA welding fume concentrations were significantly higher than the SMA welding fume concentrations. The highest fume concentration on the horizontal was shown in the fumes collected directly above the arc. The fume concentration vertically was highest at 50 cm height and reduced by half at 150 cm height. The fume concentration at 250 cm height was scarcely different from that at 150 cm height. The distribution of the chromium concentration vertically was analogous to the fume concentration, and a statistically significant difference in the chromium percentages was not found at the different heights. The nickel concentrations were not statistically significant within the welding processes, but the nickel percentages in the SMA welding fumes were statistically higher than in the MMA welding fumes. The highest nickel concentration on the horizontal was found in the fumes collected directly above the arc. The highest nickel concentration vertically showed in the fume samples collected at 50 cm height, but the greater the height the larger the nickel percentage in the fumes.

  15. Final height in central precocious puberty after long term treatment with a slow release GnRH agonist.

    PubMed Central

    Oostdijk, W; Rikken, B; Schreuder, S; Otten, B; Odink, R; Rouwé, C; Jansen, M; Gerver, W J; Waelkens, J; Drop, S

    1996-01-01

    OBJECTIVE: To study the resumption of puberty and the final height achieved in children with central precocious puberty (CPP) treated with the GnRH agonist triptorelin. PATIENTS: 31 girls and five boys with CPP who were treated with triptorelin 3.75 mg intramuscularly every four weeks. Girls were treated for a mean (SD) of 3.4 (1.0) years and were followed up for 4.0 (1.2) years after the treatment was stopped. RESULTS: The rate of bone maturation decreased during treatment and the predicted adult height increased from 158.2 (7.4) cm to 163.9 (7.5) cm at the end of treatment (p < 0.001). When treatment was stopped bone maturation accelerated, resulting in a final height of 161.6 (7.0) cm, which was higher than the predicted adult height at the start of treatment (p < 0.001). Height at the start of treatment was the most important factor positively influencing final height (r = 0.75, p < 0.001). Bone age at cessation of treatment negatively influenced final height (r = -0.52, p = 0.03). A negative correlation between bone age and height increment after discontinuation of treatment was observed (r = -0.85, p = 0.001). Residual growth capacity was optimal when bone age on cessation of treatment was 12 to 12.5 years. Body mass index increased during treatment and remained high on cessation. At final height, the ratio of sitting height to subischial leg length was normal. Menarche occurred at 12.3 (1.1) years, and at a median (range) of 1.1 (0.4 to 2.6) years after treatment was stopped. The ovaries were normal on pelvic ultrasonography. CONCLUSIONS: Treatment of CPP with triptorelin increases final height, with normal body proportions, and seems to increase body mass index. The best results were achieved in girls who were taller at the start of treatment. Puberty was resumed after treatment, without the occurrence of polycystic ovaries. PMID:8984913

  16. RSRA vertical drag test report. [rotor systems research aircraft

    NASA Technical Reports Server (NTRS)

    Flemming, R. J.

    1981-01-01

    The Rotor Systems Research Aircraft (RSRA), because of its ability to measure rotor loads, was used to conduct an experiment to determine vertical drag, tail rotor blockage, and thrust augmentation as affected by ground clearance and flight velocity. The RSRA was flown in the helicopter configuration at speeds from 0 to 15 knots for wheel heights from 5 to 150 feet, and to 60 knots out of ground effect. The vertical drag trends in hover, predicted by theory and shown in model tests, were generally confirmed. The OGE hover vertical drag is 4.0 percent, 1.1 percent greater than predicted. The vertical drag decreases rapidly as wheel height is reduced, and is zero at a wheel height of 6 feet. The vertical drag also decreases with forward speed, approaching zero at sixty knots. The test data show the effect of wheel height and forward speed on thrust, gross weight capability, and power, and provide the relationships for power and collective pitch at constant gross weight required for the simulation of helicopter takeoffs and landings.

  17. Application of modern computer-aided technologies in the production of individual bone graft: A case report.

    PubMed

    Mirković, Sinisa; Budak, Igor; Puskar, Tatjana; Tadić, Ana; Sokac, Mario; Santosi, Zeljko; Djurdjević-Mirković, Tatjana

    2015-12-01

    An autologous bone (bone derived from the patient himself) is considered to be a "golden standard" in the treatment of bone defects and partial atrophic alveolar ridge. However, large defects and bone losses are difficult to restore in this manner, because extraction of large amounts of autologous tissue can cause donor-site problems. Alternatively, data from computed tomographic (CT) scan can be used to shape a precise 3D homologous bone block using a computer-aided design-computer-aided manufacturing (CAD-CAM) system. A 63-year old male patient referred to the Clinic of Dentistry of Vojvodina in Novi Sad, because of teeth loss in the right lateral region of the lower jaw. Clinical examination revealed a pronounced resorption of the residual ridge of the lower jaw in the aforementioned region, both horizontal and vertical. After clinical examination, the patient was referred for 3D cone beam (CB)CT scan that enables visualization of bony structures and accurate measurement of dimensions of the residual alveolar ridge. Considering the large extent of bone resorption, the required ridge augmentation was more than 3 mm in height and 2 mm in width along the length of some 2 cm, thus the use of granular material was excluded. After consulting prosthodontists and engineers from the Faculty of Technical Sciences in Novi Sad we decided to fabricate an individual (custom) bovine-derived bone graft designed according to the obtained-3D CBCT scan. Application of 3D CBCT images, computer-aided systems and software in manufacturing custom bone grafts represents the most recent method of guided bone regeneration. This method substantially reduces time of recovery and carries minimum risk of postoperative complications, yet the results fully satisfy the requirements of both the patient and the therapist.

  18. Relationships between explosive and maximal triple extensor muscle performance and vertical jump height.

    PubMed

    Chang, Eunwook; Norcross, Marc F; Johnson, Sam T; Kitagawa, Taichi; Hoffman, Mark

    2015-02-01

    The purpose of this study was to examine the relationships between maximum vertical jump height and (a) rate of torque development (RTD) calculated during 2 time intervals, 0-50 milliseconds (RTD50) and 0-200 milliseconds (RTD200) after torque onset and (b) peak torque (PT) for each of the triple extensor muscle groups. Thirty recreationally active individuals performed maximal isometric voluntary contractions (MVIC) of the hip, knee and ankle extensors, and a countermovement vertical jump. Rate of torque development was calculated from 0 to 50 (RTD50) and 0 to 200 (RTD200) milliseconds after the onset of joint torque. Peak torque was identified and defined as the maximum torque value during each MVIC trial. Greater vertical jump height was associated with greater knee and ankle extension RTD50, RTD200, and PT (p ≤ 0.05). However, hip extension RTD50, RTD200, and PT were not significantly related to maximal vertical jump height (p > 0.05). The results indicate that 47.6 and 32.5% of the variability in vertical jump height was explained by knee and ankle extensor RTD50, respectively. Knee and ankle extensor RTD50 also seemed to be more closely related to vertical jump performance than RTD200 (knee extensor: 28.1% and ankle extensor: 28.1%) and PT (knee extensor: 31.4% and ankle extensor: 13.7%). Overall, these results suggest that training specifically targeted to improve knee and ankle extension RTD, especially during the early phases of muscle contraction, may be effective for increasing maximal vertical jump performance.

  19. The Shank-to-Vertical-Angle as a parameter to evaluate tuning of Ankle-Foot Orthoses.

    PubMed

    Kerkum, Yvette L; Houdijk, Han; Brehm, Merel-Anne; Buizer, Annemieke I; Kessels, Manon L C; Sterk, Arjan; van den Noort, Josien C; Harlaar, Jaap

    2015-09-01

    The effectiveness of an Ankle-Foot Orthosis footwear combination (AFO-FC) may be partly dependent on the alignment of the ground reaction force with respect to lower limb joint rotation centers, reflected by joint angles and moments. Adjusting (i.e. tuning) the AFO-FC's properties could affect this alignment, which may be guided by monitoring the Shank-to-Vertical-Angle. This study aimed to investigate whether the Shank-to-Vertical-Angle during walking responds to variations in heel height and footplate stiffness, and if this would reflect changes in joint angles and net moments in healthy adults. Ten subjects walked on an instrumented treadmill and performed six trials while walking with bilateral rigid Ankle-Foot Orthoses. The AFO-FC heel height was increased, aiming to impose a Shank-to-Vertical-Angle of 5°, 11° and 20°, and combined with a flexible or stiff footplate. For each trial, the Shank-to-Vertical-Angle, joint flexion-extension angles and net joint moments of the right leg at midstance were averaged over 25 gait cycles. The Shank-to-Vertical-Angle significantly increased with increasing heel height (p<0.001), resulting in an increase in knee flexion angle and internal knee extensor moment (p<0.001). The stiff footplate reduced the effect of heel height on the internal knee extensor moment (p=0.030), while the internal ankle plantar flexion moment increased (p=0.035). Effects of heel height and footplate stiffness on the hip joint were limited. Our results support the potential to use the Shank-to-Vertical-Angle as a parameter to evaluate AFO-FC tuning, as it is responsive to changes in heel height and reflects concomitant changes in the lower limb angles and moments. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Associations between adiposity, hormones, and gains in height, whole-body height-adjusted bone size, and size-adjusted bone mineral content in 8- to 11-year-old children.

    PubMed

    Dalskov, S; Ritz, C; Larnkjær, A; Damsgaard, C T; Petersen, R A; Sørensen, L B; Ong, K K; Astrup, A; Michaelsen, K F; Mølgaard, C

    2016-04-01

    We examined fat-independent associations of hormones with height and whole-body bone size and mineral content in 633 school children. IGF-1 and osteocalcin predict growth in height, while fat, osteocalcin, and in girls also, IGF-1 predict growth in bone size. Leptin and ghrelin are inversely associated with bone size in girls. Obesity causes larger bone size and bone mass, but the role of hormones in this up-regulation of bone in obesity is not well elucidated. We examined longitudinal associations between baseline body fat mass (FM), and fat-independent fasting levels of ghrelin, adiponectin, leptin, insulin, insulin-like growth factor-I (IGF-1), osteocalcin, and intact parathyroid hormone, and subsequent changes in height and in whole-body height-adjusted bone area "BAheight" and size-adjusted bone mineral content "BMCsize" in 8- to 11-year-olds. Analyses were carried out separately for boys (n = 325) and girls (n = 308) including data from baseline, 3 and 6 months from OPUS School Meal Study. In both sexes: gain in BAheight was positively associated with baseline FM (≥2.05 cm(2)/kg, both p ≤ 0.003). Furthermore, gain in height was positively associated with baseline IGF-1 (≥0.02 cm/ng/ml, p = 0.001) and osteocalcin (≥0.13 cm/ng/ml, p ≤ 0.009); and gain in BAheight was positively associated with baseline osteocalcin (≥0.35 cm(2)/ng/ml, p ≤ 0.019). In girls only, gain in BAheight was also positively associated with baseline IGF-1 (0.06 cm(2)/ng/ml, p = 0.017) and inversely associated with both baseline ghrelin (-0.01 cm(2)/pg/ml, p = 0.001) and leptin (-1.21 cm(2)/μg/ml, p = 0.005). In boys, gain in BMCsize was positively associated with osteocalcin (0.18 g/ng/ml, p = 0.030). This large longitudinal study suggests that in 8- to 11-year-old children, IGF-1 and osteocalcin predict growth in height, while FM, osteocalcin, and in girls also, IGF-1 predict growth in BAheight. Fat-independent inverse associations of leptin and ghrelin with BAheight in girls' are contrary to proposed growth-stimulating effects of leptin. Osteocalcin in boys predicts gain in BMCsize.

  1. Does plyometric training improve vertical jump height? A meta-analytical review.

    PubMed

    Markovic, Goran

    2007-06-01

    The aim of this study was to determine the precise effect of plyometric training (PT) on vertical jump height in healthy individuals. Meta-analyses of randomised and non-randomised controlled trials that evaluated the effect of PT on four typical vertical jump height tests were carried out: squat jump (SJ); countermovement jump (CMJ); countermovement jump with the arm swing (CMJA); and drop jump (DJ). Studies were identified by computerised and manual searches of the literature. Data on changes in jump height for the plyometric and control groups were extracted and statistically pooled in a meta-analysis, separately for each type of jump. A total of 26 studies yielding 13 data points for SJ, 19 data points for CMJ, 14 data points for CMJA and 7 data points for DJ met the initial inclusion criteria. The pooled estimate of the effect of PT on vertical jump height was 4.7% (95% CI 1.8 to 7.6%), 8.7% (95% CI 7.0 to 10.4%), 7.5% (95% CI 4.2 to 10.8%) and 4.7% (95% CI 0.8 to 8.6%) for the SJ, CMJ, CMJA and DJ, respectively. When expressed in standardised units (ie, effect sizes), the effect of PT on vertical jump height was 0.44 (95% CI 0.15 to 0.72), 0.88 (95% CI 0.64 to 1.11), 0.74 (95% CI 0.47 to 1.02) and 0.62 (95% CI 0.18 to 1.05) for the SJ, CMJ, CMJA and DJ, respectively. PT provides a statistically significant and practically relevant improvement in vertical jump height with the mean effect ranging from 4.7% (SJ and DJ), over 7.5% (CMJA) to 8.7% (CMJ). These results justify the application of PT for the purpose of development of vertical jump performance in healthy individuals.

  2. Comparing short-term complex and compound training programs on vertical jump height and power output.

    PubMed

    Mihalik, Jason P; Libby, Jeremiah J; Battaglini, Claudio L; McMurray, Robert G

    2008-01-01

    The purpose of this study was to determine whether there were differences in vertical jump height and lower body power production gains between complex and compound training programs. A secondary purpose was to determine whether differences in gains were observed at a faster rate between complex and compound training programs. Thirty-one college-aged club volleyball players (11 men and 20 women) were assigned into either a complex training group or a compound training group based on gender and pre-training performance measures. Both groups trained twice per week for 4 weeks. Work was equated between the 2 groups. Complex training alternated between resistance and plyometric exercises on each training day; whereas, compound training consisted of resistance training on one day and plyometric training on the other. Our analyses showed significant improvements in vertical jump height in both training groups after only 3 weeks of training (P < 0.0001); vertical jump height increased by approximately 5% and 9% in the complex and compound training groups, respectively. However, neither group improved significantly better than the other, nor did either group experience faster gains in vertical leap or power output. The results of this study suggest that performing a minimum of 3 weeks of either complex or compound training is effective for improving vertical jump height and power output; thus, coaches should choose the program which best suits their training schedules.

  3. Vertical variations in wood CO2 efflux for live emergent trees in a Bornean tropical rainforest.

    PubMed

    Katayama, Ayumi; Kume, Tomonori; Komatsu, Hikaru; Ohashi, Mizue; Matsumoto, Kazuho; Ichihashi, Ryuji; Kumagai, Tomo'omi; Otsuki, Kyoichi

    2014-05-01

    Difficult access to 40-m-tall emergent trees in tropical rainforests has resulted in a lack of data related to vertical variations in wood CO2 efflux, even though significant variations in wood CO2 efflux are an important source of errors when estimating whole-tree total wood CO2 efflux. This study aimed to clarify vertical variations in wood CO2 efflux for emergent trees and to document the impact of the variations on the whole-tree estimates of stem and branch CO2 efflux. First, we measured wood CO2 efflux and factors related to tree morphology and environment for seven live emergent trees of two dipterocarp species at four to seven heights of up to ∼ 40 m for each tree using ladders and a crane. No systematic tendencies in vertical variations were observed for all the trees. Wood CO2 efflux was not affected by stem and air temperature, stem diameter, stem height or stem growth. The ratios of wood CO2 efflux at the treetop to that at breast height were larger in emergent trees with relatively smaller diameters at breast height. Second, we compared whole-tree stem CO2 efflux estimates using vertical measurements with those based on solely breast height measurements. We found similar whole-tree stem CO2 efflux estimates regardless of the patterns of vertical variations in CO2 efflux because the surface area in the canopy, where wood CO2 efflux often differed from that at breast height, was very small compared with that at low stem heights, resulting in little effect of the vertical variations on the estimate. Additionally, whole-tree branch CO2 efflux estimates using measured wood CO2 efflux in the canopy were considerably different from those measured using only breast height measurements. Uncertainties in wood CO2 efflux in the canopy did not cause any bias in stem CO2 efflux scaling, but affected branch CO2 efflux. © The Author 2014. Published by Oxford University Press. All rights reserved.

  4. Effect of chiropractic manipulation on vertical jump height in young female athletes with talocrural joint dysfunction: a single-blind randomized clinical pilot trial.

    PubMed

    Hedlund, Sofia; Nilsson, Hans; Lenz, Markus; Sundberg, Tobias

    2014-02-01

    The main objective of this pilot study was to explore the effect of chiropractic high-velocity, low-amplitude (HVLA) manipulation on vertical jump height in young female athletes with talocrural joint dysfunction. This was a randomized assessor-blind clinical pilot trial. Twenty-two female handball players with talocrural joint dysfunction were randomized to receive either HVLA manipulation (n = 11) or sham treatment (n = 11) once a week during a 3-week period. The main outcome was change in vertical jump height from baseline to follow-up within and between groups after 3 weeks. Nineteen athletes completed the study. After 3 weeks, the group receiving HVLA manipulation (n = 11) had a statistically significant mean (SD) improvement in vertical jump height of 1.07 (1.23) cm (P = .017). The sham treatment group (n = 8) improved their vertical jump height by 0.59 (2.03) cm (P = .436). The between groups' change was 0.47 cm (95% confidence interval, -1.31 to 2.26; P = .571) in favor of the group receiving HVLA manipulation. Blinding and sham procedures were feasible, and there were no reported adverse events. The results of this pilot study show that a larger-scale study is feasible. Preliminary results suggest that chiropractic HVLA manipulation may increase vertical jump height in young female athletes with talocrural joint dysfunction. However, the clinical result in favor of HVLA manipulation compared with sham treatment needs statistical confirmation in a larger randomized clinical trial. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  5. Vertically resolved characteristics of air pollution during two severe winter haze episodes in urban Beijing, China

    NASA Astrophysics Data System (ADS)

    Wang, Qingqing; Sun, Yele; Xu, Weiqi; Du, Wei; Zhou, Libo; Tang, Guiqian; Chen, Chen; Cheng, Xueling; Zhao, Xiujuan; Ji, Dongsheng; Han, Tingting; Wang, Zhe; Li, Jie; Wang, Zifa

    2018-02-01

    We conducted the first real-time continuous vertical measurements of particle extinction (bext), gaseous NO2, and black carbon (BC) from ground level to 260 m during two severe winter haze episodes at an urban site in Beijing, China. Our results illustrated four distinct types of vertical profiles: (1) uniform vertical distributions (37 % of the time) with vertical differences less than 5 %, (2) higher values at lower altitudes (29 %), (3) higher values at higher altitudes (16 %), and (4) significant decreases at the heights of ˜ 100-150 m (14 %). Further analysis demonstrated that vertical convection as indicated by mixing layer height, temperature inversion, and local emissions are three major factors affecting the changes in vertical profiles. Particularly, the formation of type 4 was strongly associated with the stratified layer that was formed due to the interactions of different air masses and temperature inversions. Aerosol composition was substantially different below and above the transition heights with ˜ 20-30 % higher contributions of local sources (e.g., biomass burning and cooking) at lower altitudes. A more detailed evolution of vertical profiles and their relationship with the changes in source emissions, mixing layer height, and aerosol chemistry was illustrated by a case study. BC showed overall similar vertical profiles as those of bext (R2 = 0.92 and 0.69 in November and January, respectively). While NO2 was correlated with bext for most of the time, the vertical profiles of bext / NO2 varied differently for different profiles, indicating the impact of chemical transformation on vertical profiles. Our results also showed that more comprehensive vertical measurements (e.g., more aerosol and gaseous species) at higher altitudes in the megacities are needed for a better understanding of the formation mechanisms and evolution of severe haze episodes in China.

  6. Whole body BMC in pediatric Crohn disease: independent effects of altered growth, maturation, and body composition.

    PubMed

    Burnham, Jon M; Shults, Justine; Semeao, Edisio; Foster, Bethany; Zemel, Babette S; Stallings, Virginia A; Leonard, Mary B

    2004-12-01

    Whole body BMC was assessed in 104 children and young adults with CD and 233 healthy controls. CD was associated with significant deficits in BMC and lean mass, relative to height. Adjustment for lean mass eliminated the bone deficit in CD. Steroid exposure was associated with short stature but not bone deficits relative to height. Children with Crohn disease (CD) have multiple risk factors for impaired bone accrual. The confounding effects of poor growth and delayed maturation limit the interpretation of prior studies of bone health in CD. The objective of this study was to assess BMC relative to growth, body composition, and maturation in CD compared with controls. Whole body BMC and lean mass were assessed by DXA in 104 CD subjects and 233 healthy controls, 4-26 years of age. Multivariable linear regression models were developed to sequentially adjust for differences in skeletal size, pubertal maturation, and muscle mass. BMC-for-height z scores were derived to determine CD-specific covariates associated with bone deficits. Subjects with CD had significantly lower height z score, body mass index z score, and lean mass relative to height compared with controls (all p < 0.0001). After adjustment for group differences in age, height, and race, the ratio of BMC in CD relative to controls was significantly reduced in males (0.86; 95% CI, 0.83, 0.94) and females (0.91; 95% CI, 0.85, 0.98) with CD. Adjustment for pubertal maturation did not alter the estimate; however, addition of lean mass to the model eliminated the bone deficit. Steroid exposure was associated with short stature but not bone deficits. This study shows the importance of considering differences in body size and composition when interpreting DXA data in children with chronic inflammatory conditions and shows an association between deficits in muscle mass and bone in pediatric CD.

  7. Histomorphometric analysis after maxillary sinus floor augmentation using cancellous bone-block allograft.

    PubMed

    Chaushu, Gavriel; Vered, Marilena; Mardinger, Ofer; Nissan, Joseph

    2010-08-01

    Cancellous bone-block allografts may contribute to improved initial implant stability during sinus augmentation in cases with posterior atrophic maxillary ridge height < or =4 mm. The present study histologically and histomorphometrically evaluates the application of cancellous bone-block allografts for maxillary sinus-floor augmentation. Thirty-one consecutive patients, 16 females and 15 males (age range, 25 to 65 years; mean age: 54 +/- 9 years) underwent sinus augmentation with simultaneous implant placement with cancellous bone-block allografts. After 9 months, a second-stage surgery was performed. The previous window location was determined. A cylindrical sample core was collected. All specimens were prepared for histologic and histomorphometric examinations. Seventy-two of 76 implants were clinically osseointegrated (94.7%). All patients received a fixed implant-supported prosthesis. The mean t values of newly formed bone, residual cancellous bone-block allograft, marrow and connective tissue were 26.1% +/- 15% (range: 10% to 58%); 24.7% +/- 19.4% (range: 0.6% to 71%), and 49.2% +/- 20.4% (range: 14.9% to 78.9%), respectively. No statistically significant histomorphometric differences regarding newly formed bone were found between genders (27.02% in males versus 25.68% in females; P = 0.446), ages (29.82% in subjects < or =40 years old versus 24.43% in subjects >40 years old; P = 0.293), presence of membrane perforations (25.5% in non-perforated sinuses versus 27.3% in perforated sinuses; P = 0.427), and residual alveolar bone height (25.85% for residual alveolar bone height <2 mm versus 26.48% for residual alveolar bone height of 2 to 4 mm; P = 0.473). The cancellous bone-block allograft is biocompatible and osteoconductive and permits new bone formation in sinus augmentations with simultaneous implant-placement procedures in extremely atrophic posterior maxillae.

  8. Human talus bones from the Middle Pleistocene site of Sima de los Huesos (Sierra de Atapuerca, Burgos, Spain).

    PubMed

    Pablos, Adrián; Martínez, Ignacio; Lorenzo, Carlos; Gracia, Ana; Sala, Nohemi; Arsuaga, Juan Luis

    2013-07-01

    Here we present and describe comparatively 25 talus bones from the Middle Pleistocene site of the Sima de los Huesos (SH) (Sierra de Atapuerca, Burgos, Spain). These tali belong to 14 individuals (11 adult and three immature). Although variation among Middle and Late Pleistocene tali tends to be subtle, this study has identified unique morphological characteristics of the SH tali. They are vertically shorter than those of Late Pleistocene Homo sapiens, and show a shorter head and a broader lateral malleolar facet than all of the samples. Moreover, a few shared characters with Neanderthals are consistent with the hypothesis that the SH population and Neanderthals are sister groups. These shared characters are a broad lateral malleolar facet, a trochlear height intermediate between modern humans and Late Pleistocene H. sapiens, and a short middle calcaneal facet. It has been possible to propose sex assignment for the SH tali based on their size. Stature estimates based on these fossils give a mean stature of 174.4 cm for males and 161.9 cm for females, similar to that obtained based on the long bones from this same site. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. An Algorithm for the Vertical Structure of Aerosol Extinction in the Lowest Kilometer of the Atmosphere: Rev. 1

    DTIC Science & Technology

    2017-11-01

    inversion layer, or the well-mixed boundary layer. In such cases a low cloud ceiling is not present. In all instances the atmospheric extinction profiles...height, radiation fog depth, or the inversion layer height. The visibility regions and several representative vertical profiles of extinction are...the coefficient B can be found by B = ln(D/A) . (2) The coefficient B is sometimes a function of the cloud ceiling height, the inversion layer height

  10. Pre-augmentation soft tissue expansion improves scaffold-based vertical bone regeneration - a randomized study in dogs.

    PubMed

    Kaner, Doğan; Zhao, Han; Arnold, Wolfgang; Terheyden, Hendrik; Friedmann, Anton

    2017-06-01

    Soft tissue (ST) dehiscence with graft exposure is a frequent complication of vertical augmentation. Flap dehiscence is caused by failure to achieve tension-free primary wound closure and by the impairment of flap microcirculation due to surgical trauma. Soft tissue expansion (STE) increases ST quality and quantity prior to reconstructive surgery. We hypothesized that flap preconditioning using STE would reduce the incidence of ST complications after bone augmentation and that optimized ST healing would improve the outcome of bone regeneration. Self-filling tissue expanders were implanted in mandibular bone defects in ten beagle dogs. After expansion, alloplastic scaffolds were placed for vertical bone augmentation in STE sites and in control sites without STE pre-treatment. ST flap microcirculation was analysed using laser Doppler flowmetry. The incidence of graft exposures was evaluated after 2 weeks. Bone formation was assessed after 2 months, using histomorphometry and immunohistochemistry. Test sites showed significantly less impairment of perfusion and faster recovery of microcirculation after bone augmentation. Furthermore, no flap dehiscences occurred in STE sites. Bone regeneration was found in both groups; however, significantly greater formation of new bone was detected in test sites with preceding STE. Preconditioning using STE improved ST healing and bone formation after vertical augmentation. The combination of STE and the subsequent placement of alloplastic scaffolds may facilitate the reconstruction of severe bone defects. © 2016 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  11. Growth, sexual and bone development in a boy with bilateral anorchia under testosterone treatment guided by the development of his monozygotic twin.

    PubMed

    Vandewalle, Sara; Van Caenegem, Eva; Craen, Margarita; Taes, Youri; Kaufman, Jean-Marc; T'Sjoen, Guy

    2018-03-28

    Sex steroids are essential for sexual maturation, linear growth and bone development. However, there is no consensus on the optimal timing, dosage and dosage interval of testosterone therapy to induce pubertal development and achieve a normal adult height and bone mass in children with hypogonadism. A monozygotic monochorial male twin pair, of which one boy was diagnosed with anorchia at birth due to testicular regression syndrome was followed from the age of 3 until the age of 18 years. Low dose testosterone substitution (testosterone esters 25 mg/2 weeks) was initiated in the affected twin based on the start of pubertal development in the healthy twin and then gradually increased accordingly. Both boys were followed until age 18 and were compared as regards to linear growth, sexual maturation, bone maturation and bone development. Before puberty induction both boys had a similar weight and height. During puberty, a slightly faster weight and height gain was observed in the affected twin. Both boys ended up however, with a similar and normal (near) adult height and weight and experienced a normal development of secondary sex characteristics. At the age of 17 and 18 years, bone mineral density, body composition and volumetric bone parameters at the forearm and calf were evaluated in both boys. The affected boy had a higher lean mass and muscle cross-sectional area. The bone mineral density at the lumbar spine and whole body was similar. Trabecular and cortical volumetric bone parameters were comparable. At one cortical site (proximal radius), however, the affected twin had a smaller periosteal and endosteal circumference with a thicker cortex. In conclusion, a low dose testosterone substitution in bilateral anorchia led to a normal onset of pubertal development and (near) adult height. Furthermore, there was no difference in bone mineral density at the age of 17 and 18 years.

  12. Satellite remote sensing and ozonesonde observation of ozone vertical profile and severe storm development

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Liu, J. M.

    1988-01-01

    Two year ozonesonde data, January 1981 to December 1982, observed at four Canadian stations, and two-and-a-half year backscattered ultraviolet experiment data on the Nimbus-4 satellite, April 1970 to August 1972, observed over five U.S. stations, were used to study the relationship between the total ozone, vertical distribution of the ozone mixing ratio, height of half the total ozone, and the variation of local tropopause height. In view of the correlation between the variation of the tropopause height and the possible development of severe storms, a better understanding of the effect of the vertical distribution of the local ozone profile on the variation of the tropopause height can give considerable insight into the development of severe storms.

  13. One-Year Follow-up of the CAPO Kids Trial: Are Physical Benefits Maintained?

    PubMed

    Nogueira, Rossana C; Weeks, Benjamin K; Beck, Belinda

    2017-11-01

    To determine the 12-month maintenance of a 9-month, thrice-weekly, 10-minute high-intensity exercise program, delivered in schools, on bone and other health-related performance variables in prepubertal children. All participants (N = 311) of the CAPO kids trial (testing times T1-T2) were contacted to undergo retesting (T3) of all original measures-including weight, standing and sitting height, calcaneal broadband ultrasound attenuation (Achilles, GE), and stiffness index (Achilles, GE)-waist circumference, resting heart rate, blood pressure, vertical jump, and aerobic capacity. Maturity was determined by estimating age of peak height velocity using sex-specific regression equations. A total of 240 children [12.3 (0.6) y old] were included in the current study (77% of initial follow-up sample at T2). Between the T2 and T3 time points, both exercise (EX) group and control (CON) group increased broadband ultrasound attenuation (EX: 5.6%, P ≤ .001; CON: 6.5%, P ≤ .001), stiffness index (EX: 7.3%, P ≤ .001; CON: 5.2%, P ≤ .001), vertical jump (EX: 5.9%, P ≤ .001; CON: 6.3%, P ≤ .001), estimated maximal oxygen consumption (EX: 13.3%, P ≤ .001; CON: 12.1%, P ≤ .001), and reduced waist circumference (EX: -5.2%, P ≤ .001; CON: -5.6%, P ≤ .001), with no between-group differences in the magnitude of those changes. No differences were detected in absolute values between groups at T3. Although the statistically significant differences observed between groups following the intervention were no longer significant 1 year after withdrawal of the intervention, the between-group similarities in growth trajectories of those parameters could suggest that some benefit of the intervention for bone health, waist circumference, and physical performance endured.

  14. Radiographic comparison of different concentrations of recombinant human bone morphogenetic protein with allogenic bone compared with the use of 100% mineralized cancellous bone allograft in maxillary sinus grafting.

    PubMed

    Froum, Stuart J; Wallace, Stephen; Cho, Sang-Choon; Khouly, Ismael; Rosenberg, Edwin; Corby, Patricia; Froum, Scott; Mascarenhas, Patrick; Tarnow, Dennis P

    2014-01-01

    The purpose of this study was to radiographically evaluate, then analyze, bone height, volume, and density with reference to percentage of vital bone after maxillary sinuses were grafted using two different doses of recombinant human bone morphogenetic protein 2/acellular collagen sponge (rhBMP-2/ACS) combined with mineralized cancellous bone allograft (MCBA) and a control sinus grafted with MCBA only. A total of 18 patients (36 sinuses) were used for analysis of height and volume measurements, having two of three graft combinations (one in each sinus): (1) control, MCBA only; (2) test 1, MCBA + 5.6 mL of rhBMP-2/ACS (containing 8.4 mg of rhBMP-2); and (3) test 2, MCBA + 2.8 mL of rhBMP-2/ACS (containing 4.2 mg of rhBMP-2). The study was completed with 16 patients who also had bilateral cores removed 6 to 9 months following sinus augmentation. A computer software system was used to evaluate 36 computed tomography scans. Two time points where selected for measurements of height: The results indicated that height of the grafted sinus was significantly greater in the treatment groups compared with the control. However, by the second time point, there were no statistically significant differences. Three weeks post-surgery bone volume measurements showed similar statistically significant differences between test and controls. However, prior to core removal, test group 1 with the greater dose of rhBMP-2 showed a statistically significant greater increase compared with test group 2 and the control. There was no statistically significant difference between the latter two groups. All three groups had similar volume and shrinkage. Density measurements varied from the above results, with the control showing statistically significant greater density at both time points. By contrast, the density increase over time in both rhBMP groups was similar and statistically higher than in the control group. There were strong associations between height and volume in all groups and between volume and new vital bone only in the control group. There were no statistically significant relationships observed between height and bone density or between volume and bone density for any parameter measured. More cases and monitoring of the future survival of implants placed in these augmented sinuses are needed to verify these results.

  15. Vertical facial height and its correlation with facial width and depth: Three dimensional cone beam computed tomography evaluation based on dry skulls.

    PubMed

    Wang, Ming Feng; Otsuka, Takero; Akimoto, Susumu; Sato, Sadao

    2013-01-01

    The aim of the present study was to evaluate how vertical facial height correlates with mandibular plane angle, facial width and depth from a three dimensional (3D) viewing angle. In this study 3D cephalometric landmarks were identified and measurements from 43 randomly selected cone beam computed tomography (CBCT) images of dry skulls from the Weisbach collection of Vienna Natural History Museum were analyzed. Pearson correlation coefficients of facial height measurements and mandibular plane angle and the correlation coefficients of height-width and height-depth were calculated, respectively. The mandibular plane angle (MP-SN) significantly correlated with ramus height (Co-Go) and posterior facial height (PFH) but not with anterior lower face height (ALFH) or anterior total face height (ATFH). The ALFH and ATFH showed significant correlation with anterior cranial base length (S-N), whereas PFH showed significant correlation with the mandible (S-B) and maxilla (S-A) anteroposterior position. High or low mandibular plane angle might not necessarily be accompanied by long or short anterior face height, respectively. The PFH rather than AFH is assumed to play a key role in the vertical facial type whereas AFH seems to undergo relatively intrinsic growth.

  16. Biomechanical evaluation of implant-supported prosthesis with various tilting implant angles and bone types in atrophic maxilla: A finite element study.

    PubMed

    Gümrükçü, Zeynep; Korkmaz, Yavuz Tolga; Korkmaz, Fatih Mehmet

    2017-07-01

    The purpose of this study is to evaluate and compare bone stress that occurs as a result of using vertical implants with simultaneous sinus augmentation with bone stress generated from oblique implants without sinus augmentation in atrophic maxilla. Six, three-dimensional (3D) finite element (FE) models of atrophic maxilla were generated with SolidWorks software. The maxilla models were varied for two different bone types. Models 2a, 2b and 2c represent maxilla models with D2 bone type. Models 3a, 3b and 3c represent maxilla models with D3 bone type. Five implants were embedded in each model with different configurations for vertical implant insertion with sinus augmentation: Model 2a/Model 3a, 30° tilted insertion; Model 2b/Model 3b and 45° tilted insertion; Model 2c/Model 3c. A 150 N load was applied obliquely on the hybrid prosthesis. The maximum von Mises stress values were comparatively evaluated using color scales. The von Mises stress values predicted by the FE models were higher for all D3 bone models in both cortical and cancellous bone. For the vertical implant models, lower stress values were found in cortical bone. Tilting of the distal implants by 30° increased the stress in the cortical layer compared to vertical implant models. Tilting of the distal implant by 45° decreased the stress in the cortical bone compared to the 30° models, but higher stress values were detected in the 45° models compared to the vertical implant models. Augmentation should be the first treatment option in atrophic maxilla in terms of biomechanics. Tilted posterior implants can create higher stress values than vertical posterior implants. During tilting implant planning, the use of a 45° tilted implant results in better biomechanical performance in peri-implant bone than 30° tilted implant due to the decrease in cantilever length. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor.

    PubMed

    Koca, Omer Lutfi; Eskitascioglu, Gurcan; Usumez, Aslihan

    2005-01-01

    Implants placed in the posterior maxilla have lower success rates compared to implants placed in other oral regions. Inadequate bone levels have been suggested as a reason for this differential success rate. The purpose of this study was to determine the amount and localization of functional stresses in implants and adjacent bone locations when the implants were placed in the posterior maxilla in proximity to the sinus using finite element analysis (FEA). A 3-dimensional finite element model of a maxillary posterior section of bone (Type 3) was used in this study. Different bony dimensions were generated to perform nonlinear calculations. A single-piece 4.1x10-mm screw-shaped dental implant system (ITI solid implant) was modeled and inserted into atrophic maxillary models with crestal bone heights of 4, 5, 7, 10, or 13 mm. In some models the implant penetrated the sinus floor. Cobalt-Chromium (Wiron 99) was used as the crown framework material placed onto the implant, and porcelain was used for occlusal surface of the crown. A total average occlusal force (vertical load) of 300 N was applied at the palatal cusp (150 N) and mesial fossa (150 N) of the crown. The implant and superstructure were simulated in finite element software (Pro/Engineer 2000i program). For the porcelain superstructure for bone levels, maximum von Mises stress values were observed on the mesial fossae and palatal cusp. For the bone structure, the maximum von Mises stress values were observed in the palatal cortical bone adjacent to the implant neck. There was no stress within the spongy bone. High stresses occurred within the implants for all bone levels. The maximum von Mises stresses in the implants were localized in the neck of implants for 4- and 5-mm bone levels, but for 7-, 10-, and 13-mm bone levels more even stresses occurred within the implants.

  18. Anthropometry as a predictor of vertical jump heights derived from an instrumented platform.

    PubMed

    Caruso, John F; Daily, Jeremy S; Mason, Melissa L; Shepherd, Catherine M; McLagan, Jessica R; Marshall, Mallory R; Walker, Ron H; West, Jason O

    2012-01-01

    The current study purpose examined the vertical height-anthropometry relationship with jump data obtained from an instrumented platform. Our methods required college-aged (n = 177) subjects to make 3 visits to our laboratory to measure the following anthropometric variables: height, body mass, upper arm length (UAL), lower arm length, upper leg length, and lower leg length. Per jump, maximum height was measured in 3 ways: from the subjects' takeoff, hang times, and as they landed on the platform. Standard multivariate regression assessed how well anthropometry predicted the criterion variance per gender (men, women, pooled) and jump height method (takeoff, hang time, landing) combination. Z-scores indicated that small amounts of the total data were outliers. The results showed that the majority of outliers were from jump heights calculated as women landed on the platform. With the genders pooled, anthropometry predicted a significant (p < 0.05) amount of variance from jump heights calculated from both takeoff and hang time. The anthropometry-vertical jump relationship was not significant from heights calculated as subjects landed on the platform, likely due to the female outliers. Yet anthropometric data of men did predict a significant amount of variance from heights calculated when they landed on the platform; univariate correlations of men's data revealed that UAL was the best predictor. It was concluded that the large sample of men's data led to greater data heterogeneity and a higher univariate correlation. Because of our sample size and data heterogeneity, practical applications suggest that coaches may find our results best predict performance for a variety of college-aged athletes and vertical jump enthusiasts.

  19. Early diet and peak bone mass: 20 year follow-up of a randomized trial of early diet in infants born preterm.

    PubMed

    Fewtrell, Mary S; Williams, Jane E; Singhal, Atul; Murgatroyd, Peter R; Fuller, Nigel; Lucas, Alan

    2009-07-01

    Preterm infants are at risk of metabolic bone disease due to inadequate mineral intake with unknown consequences for later bone health. To test the hypotheses that (1) early diet programs peak bone mass and bone turnover; (2) human milk has a beneficial effect on these outcomes; (3) preterm subjects have reduced peak bone mass compared to population reference data. 20 year follow-up of 202 subjects (43% male; 24% of survivors) who were born preterm and randomized to: (i) preterm formula versus banked breast milk or (ii) preterm versus term formula; as sole diet or supplement to maternal milk. Outcome measures were (i) anthropometry; (ii) hip, lumbar spine (LS) and whole body (WB) bone mineral content (BMC) and bone area (BA) measured using DXA; (iii) bone turnover markers. Infant dietary randomization group did not influence peak bone mass or turnover. The proportion of human milk in the diet was significantly positively associated with WBBA and BMC. Subjects receiving >90% human milk had significantly higher WBBA (by 3.5%, p=0.01) and BMC (by 4.8%, p=0.03) than those receiving <10%. Compared to population data, subjects had significantly lower height SDS (-0.41 (SD 1.05)), higher BMI SDS (0.31 (1.33)) and lower LSBMD SDS (-0.29 (1.16)); height and bone mass deficits were greatest in those born SGA with birthweight <1250 g (height SDS -0.81 (0.95), LSBMD SDS -0.61 (1.3)). Infant dietary randomization group did not affect peak bone mass or turnover suggesting the observed reduced final height and LS bone mass, most marked in growth restricted subjects with the lowest birthweight, may not be related to sub-optimal early nutrition. The higher WB bone mass associated with human milk intake, despite its low nutrient content, may reflect non-nutritive factors in breast milk. These findings may have implications for later osteoporosis risk and require further investigation.

  20. Can we predict body height from segmental bone length measurements? A study of 3,647 children.

    PubMed

    Cheng, J C; Leung, S S; Chiu, B S; Tse, P W; Lee, C W; Chan, A K; Xia, G; Leung, A K; Xu, Y Y

    1998-01-01

    It is well known that significant differences exist in the anthropometric data of different races and ethnic groups. This is a cross-sectional study on segmental bone length based on 3,647 Chinese children of equal sex distribution aged 3-18 years. The measurements included standing height, weight, arm span, foot length, and segmental bone length of the humerus, radius, ulna, and tibia. A normality growth chart of all the measured parameters was constructed. Statistical analysis of the results showed a very high linear correlation of height with arm span, foot length, and segmental bone lengths with a correlation coefficient of 0.96-0.99 for both sexes. No differences were found between the right and left side of all the segmental bone lengths. These Chinese children were found to have a proportional limb segmental length relative to the trunk.

  1. The type of mat (Contact vs. Photocell) affects vertical jump height estimated from flight time.

    PubMed

    García-López, Juan; Morante, Juan C; Ogueta-Alday, Ana; Rodríguez-Marroyo, Jose A

    2013-04-01

    The purposes of this study were to analyze the validity and reliability of 2 photocell mats and to probe the possible influence of the type of mat (contact vs. photocell) on vertical jump height estimated from flight time. In 2 separate studies, 89 and 92 physical students performed 3 countermovement jumps that were simultaneously registered by a Force Plate (gold standard method), 2 photocell mats (SportJump System Pro and ErgoJump Plus), and a contact mat (SportJump-v1.0). The first study showed that the 2 photocell mats underestimated the vertical jump height (1.3 ± 0.2 cm and 5.9 ± 5.2 cm, respectively), but only SportJump System Pro showed a high correlation with the Force Plate (r = 0.999 and 0.676, respectively) and good intraday reliability (coefficient of variation = 2.98 and 15.94%, intraclass correlation coefficients = 0.95-0.97 and 0.45-0.57, respectively). The second study demonstrated a strong correlation (r = 0.994) between the 2 technologies (contact vs. photocell mats) with differences in vertical jump height of 2.0 ± 0.8 cm (95% confidence interval = 1.9-2.1 cm), which depended on both flight time and subjects' body mass. In conclusion, SportJump System Pro was a valid and reliable device. The new devices to measure vertical jump height from flight time should be validated. The type of mat (contact vs. photocell) affected approximately 6% the vertical jump height (approximately 2 cm in this study), which should be considered in further studies. The use of validated photocell mats instead of the contact mats was recommended.

  2. Height adjustment in assessing dual energy x-ray absorptiometry measurements of bone mass and density in children.

    PubMed

    Zemel, Babette S; Leonard, Mary B; Kelly, Andrea; Lappe, Joan M; Gilsanz, Vicente; Oberfield, Sharon; Mahboubi, Soroosh; Shepherd, John A; Hangartner, Thomas N; Frederick, Margaret M; Winer, Karen K; Kalkwarf, Heidi J

    2010-03-01

    In children, bone mineral content (BMC) and bone mineral density (BMD) measurements by dual-energy x-ray absorptiometry (DXA) are affected by height status. No consensus exists on how to adjust BMC or BMD (BMC/BMD) measurements for short or tall stature. The aim of this study was to compare various methods to adjust BMC/BMD for height in healthy children. Data from the Bone Mineral Density in Childhood Study (BMDCS) were used to develop adjustment methods that were validated using an independent cross-sectional sample of healthy children from the Reference Data Project (RDP). We conducted the study in five clinical centers in the United States. We included 1546 BMDCS and 650 RDP participants (7 to 17 yr of age, 50% female). No interventions were used. We measured spine and whole body (WB) BMC and BMD Z-scores for age (BMC/BMD(age)), height age (BMC/BMD(height age)), height (BMC(height)), bone mineral apparent density (BMAD(age)), and height-for-age Z-score (HAZ) (BMC/BMD(haz)). Spine and WB BMC/BMD(age)Z and BMAD(age)Z were positively (P < 0.005; r = 0.11 to 0.64) associated with HAZ. Spine BMD(haz) and BMC(haz)Z were not associated with HAZ; WB BMC(haz)Z was modestly associated with HAZ (r = 0.14; P = 0.0003). All other adjustment methods were negatively associated with HAZ (P < 0.005; r = -0.20 to -0.34). The deviation between adjusted and BMC/BMD(age) Z-scores was associated with age for most measures (P < 0.005) except for BMC/BMD(haz). Most methods to adjust BMC/BMD Z-scores for height were biased by age and/or HAZ. Adjustments using HAZ were least biased relative to HAZ and age and can be used to evaluate the effect of short or tall stature on BMC/BMD Z-scores.

  3. [Final height in symptomatic boys with late-onset adrenal hyperplasia (LOCAH), treated with glucocorticoids. Clinical cases].

    PubMed

    Pasqualini, Titania; Alonso, Guillermo; Fernández, Cecilia; Buzzalino, Noemí; Dain, Liliana

    2013-04-01

    Although corticoid replacement is recommended for those late-onset adrenal hyperplasia with clinical manifestations, asymptomatic patients do not need treatment. We describe clinical features at diagnosis, treatment, and growth till adult- height, in 4 boys. At diagnosis, age ranged from 9.2-11.6 years. The initial symptoms/signs were: precocious pubarche (n = 2), accelerated bone age (n = 1) and precocious puberty (n = 1). All of them presented elevated 17 hydroxyprogesterone levels and were compound heterozygotes carrying p.V281L mutation. Since, at diagnosis, bone age was significantly advanced for chronological age (13.1 ± 0.5 vs. 10.2 ± 1.1 p = 0.008), hydrocortisone therapy was initiated. During follow-up, mean height Z score decreased 1.4 ± 0.4 SDS (p = 0.007), though adult mean height was not different from target height (-0.39 ± 0.7 vs. -0.04 ± 0.5 SDS, p = 0.054). In conclusion, in 4 symptomatic patients, accurate treatment of late-onset adrenal hyperplasia led to an adult mean height not different from target height. Advanced bone age at diagnosis and the loss of height during pubertal development suggest the need of therapy.

  4. Evaluation of maxillary alveolar reconstruction using a resorbable collagen sponge with recombinant human bone morphogenetic protein-2 in cleft lip and palate patients.

    PubMed

    Alonso, Nivaldo; Tanikawa, Daniela Yukie Sakai; Freitas, Renato da Silva; Canan, Lady; Ozawa, Terumi Okada; Rocha, Diógenes Laércio

    2010-10-01

    A resorbable collagen matrix with recombinant human bone morphogenetic protein (rhBMP-2) was compared with traditional iliac crest bone graft for the closure of alveolar defects during secondary dental eruption. Sixteen patients with unilateral cleft lip and palate, aged 8 to 12 years, were selected and randomly assigned to group 1 (rhBMP-2) or group 2 (iliac crest bone graft). Computed tomography was performed to assess both groups preoperatively and at months 6 and 12 postoperatively. Bone height and defect volume were calculated through Osirix Dicom Viewer (Pixmeo, Apple Inc.). Overall morbidity was recorded. Preoperative and follow-up examinations revealed progressive alveolar bone union in all patients. For group 1, final completion of the defect with a 65.0% mean bone height was detected 12 months postoperatively. For group 2, final completion of the defect with an 83.8% mean bone height was detected 6 months postoperatively. Dental eruption routinely occurred in both groups. Clinical complications included significant swelling in three group 1 patients (37.5%) and significant donor-site pain in seven group 2 patients (87.5%). For this select group of patients with immature skeleton, rhBMP-2 therapy resulted in satisfactory bone healing and reduced morbidity compared with traditional iliac crest bone grafting.

  5. The influence of anthropometry and body composition on children's bone health: the childhood health, activity and motor performance school (the CHAMPS) study, Denmark.

    PubMed

    Heidemann, Malene; Holst, René; Schou, Anders J; Klakk, Heidi; Husby, Steffen; Wedderkopp, Niels; Mølgaard, Christian

    2015-02-01

    Overweight, physical inactivity and sedentary behaviour have become increasing problems during the past decade. Increased sedentary behaviour may change the body composition (BC) by increasing the fat mass relative to the lean mass (LM). These changes may influence bone health to describe how anthropometry and BC predict the development of the bone accruement. The longitudinal study is a part of The CHAMPS study-DK. Children were DXA scanned at baseline and at 2-year follow-up. BC (LM, BF %) and BMC, BMD and BA were measured. The relationship between bone traits, anthropometry and BC was analysed by multilevel regression analyses. Of the invited children, 742/800 (93%) accepted to participate. Of these, 682/742 (92%) participated at follow-up. Mean (range) of age at baseline was 9.5 years (7.7-12.1). Height, BMI, LM and BF % predicted bone mineral accrual and bone size positively and independently. Height and BMI are both positive predictors of bone accruement. LM is a more precise predictor of bone traits than BF % in both genders. The effects of height and BMI and LM on bone accruement are nearly identical in the two genders, while changes in BF % have different but positive effects on bone accretion in both boys and girls.

  6. A sensor fusion method for tracking vertical velocity and height based on inertial and barometric altimeter measurements.

    PubMed

    Sabatini, Angelo Maria; Genovese, Vincenzo

    2014-07-24

    A sensor fusion method was developed for vertical channel stabilization by fusing inertial measurements from an Inertial Measurement Unit (IMU) and pressure altitude measurements from a barometric altimeter integrated in the same device (baro-IMU). An Extended Kalman Filter (EKF) estimated the quaternion from the sensor frame to the navigation frame; the sensed specific force was rotated into the navigation frame and compensated for gravity, yielding the vertical linear acceleration; finally, a complementary filter driven by the vertical linear acceleration and the measured pressure altitude produced estimates of height and vertical velocity. A method was also developed to condition the measured pressure altitude using a whitening filter, which helped to remove the short-term correlation due to environment-dependent pressure changes from raw pressure altitude. The sensor fusion method was implemented to work on-line using data from a wireless baro-IMU and tested for the capability of tracking low-frequency small-amplitude vertical human-like motions that can be critical for stand-alone inertial sensor measurements. Validation tests were performed in different experimental conditions, namely no motion, free-fall motion, forced circular motion and squatting. Accurate on-line tracking of height and vertical velocity was achieved, giving confidence to the use of the sensor fusion method for tracking typical vertical human motions: velocity Root Mean Square Error (RMSE) was in the range 0.04-0.24 m/s; height RMSE was in the range 5-68 cm, with statistically significant performance gains when the whitening filter was used by the sensor fusion method to track relatively high-frequency vertical motions.

  7. Surface microstructuring of biocompatible bone analogue material HAPEX using LIGA technique and embossing

    NASA Astrophysics Data System (ADS)

    Schneider, Andreas; Rea, Susan; Huq, Ejaz; Bonfield, William

    2003-04-01

    HAPEX is an artificial bone analogue composite based on hydroxyapatite and polyethylene, which can be applied for growth of bone cells. Due to its biocompatibility and favourable mechanical properties, HAPEX is used for orthopaedic implants like tympanic (middle ear) bones. The morphology of HAPEX surfaces is of high interest and it is believed that surface structuring on a micron scale might improve the growth conditions for bone cells. A new and simple approach for the microstructuring of HAPEX surfaces has been investigated using LIGA technique. LIGA is a combination of several processes, in particular lithography, electroplating and forming/moulding. For HAPEX surface structuring, arrays of dots, grids and lines with typical lateral dimension ranging from 5 μm to 50 μm were created on a chromium photomask and the patterns were transferred into thick SU-8 photoresist (structure height > 10 μm) by UV lithography. Subsequently, the SU-8 structures served as moulds for electroplating nickel on Si wafers and nickel substrates. The final nickel microstructures were used as embossing master for the HAPEX material. Embossing was carried out using a conventional press (> 500 hPa) with the facility to heat the master and the HAPEX. The temperature ranged from ambient to a few degrees above glass transition temperature (Tg) of HAPEX. The paper will include details of the fabrication process and process tolerances in lateral and vertical directions. Data obtained are correlated to the temperature used during embossing.

  8. Three-dimensional CAD/CAM imaging of the maxillary sinus in ageing process.

    PubMed

    Lovasova, Kvetuse; Kachlik, David; Rozpravkova, Mirela; Matusevska, Maria; Ferkova, Jana; Kluchova, Darina

    2018-04-05

    During the physiological ageing process atrophy of the alveolar bone appears in vertical direction. This bone resorption causes pushing the limits of the maxillary sinus at the expense of a degraded bone. The sinus volume increases due to the facial development in children and adolescents or during the ageing process due to the loss of teeth and bone mass. The main aim of this study is to determine the sinus shape and sinus floor morphology related to age. Human adult male and female cadaveric heads (aged 37 to 83 years) with different dental status were used. The three-dimensional CAD/CAM software was used to scan the solid impressions of the maxillary sinus to visualize the real sinus shape and sinus floor. Subsequently, other findings are shown in tables and evaluated graphically. The maxillary sinus morphology, its relationship to the nasal cavity, the sub sinus alveolar bone height, displacement of the lowest and highest points of sinus, and the sinus relationship to the roots of the upper teeth were studied and evaluated. Some septa, crests, and the prominent infraorbital canal were also found in the area of the sinus floor. This paper provides a unique view on the maxillary sinus and its changes during the ageing process with preserved topographical relations in a representative sample of the Slovak population. The visualization of the maxillary sinus anatomy is necessary in the diagnosis and treatment plans for dental implants and during current surgical procedures. Copyright © 2018 Elsevier GmbH. All rights reserved.

  9. Effect of 1% sodium alendronate in the non-surgical treatment of periodontal intraosseous defects: a 6-month clinical trial

    PubMed Central

    DUTRA, Bernardo Carvalho; OLIVEIRA, Alcione Maria Soares Dutra; OLIVEIRA, Peterson Antônio Dutra; MANZI, Flavio Ricardo; CORTELLI, Sheila Cavalca; COTA, Luís Otávio de Miranda; COSTA, Fernando Oliveira

    2017-01-01

    Abstract Background and objectives Few studies have evaluated the effect of the topical application of sodium alendronate (ALN) on the treatment of intrabuccal bone defects, especially those caused by periodontitis. This 6-month randomized placebo controlled clinical trial aimed at evaluating the effect of non-surgical periodontal treatment associated with the use of 1% ALN, through clinical evaluations and cone-beam computed tomography (CBCT). Material and Methods Twenty individuals with chronic periodontitis underwent periodontal examination at the baseline as well as 3 and 6 months after periodontal treatment, registering clinical attachment level (CAL), periodontal probing depth (PPD), and bleeding on probing (BOP) as the clinical outcomes. After manual scaling and root planing, 40 bilateral sites with interproximal vertical bone defects were randomly treated with either 1% ALN gel or a placebo. Bone defects were evaluated through CBCT at the baseline and 6 months post-treatment. The clinical and CBCT parameters were compared using the Wilcoxon and Friedman tests (p<0.05). Results Although ALN produced a greater CAL gain when compared to the placebo at 6 months post-treatment (p=0.021), both treatments produced similar effects on the PPD, BOP, and bone height. Significant differences in bone fill were observed only in patients of the ALN group (4.5 to 3.8 mm; p=0.003) at 6 months post-treatment. Conclusions Topical application of 1% ALN might be a beneficial adjuvant to non-surgical periodontal therapy. PMID:28678950

  10. Mapping tropical dry forest height, foliage height profiles and disturbance type and age with a time series of cloud-cleared Landsat and ALI image mosaics to characterize avian habitat

    Treesearch

    E.H. Helmer; Thomas S. Ruzycki; Jr. Joseph M. Wunderle; Shannon Vogesser; Bonnie Ruefenacht; Charles Kwit; Thomas J. Brandeis; David N. Ewert

    2010-01-01

    Remote sensing of forest vertical structure is possible with lidar data, but lidar is not widely available. Here we map tropical dry forest height (RMSE=0.9 m, R2=0.84, range 0.6–7 m), and we map foliage height profiles, with a time series of Landsat and Advanced Land Imager (ALI) imagery on the island of Eleuthera, The Bahamas, substituting time for vertical canopy...

  11. Effects of vertical wall and tetrapod weights on wave overtopping in rubble mound breakwaters under irregular wave conditions

    NASA Astrophysics Data System (ADS)

    Park, Sang Kil; Dodaran, Asgar Ahadpour; Han, Chong Soo; Shahmirzadi, Mohammad Ebrahim Meshkati

    2014-12-01

    Rubble mound breakwaters protect the coastal line against severe erosion caused by wave action. This study examined the performance of different sizes and properties (i.e. height of vertical wall and tetrapod size) of rubble mound breakwaters on reducing the overtopping discharge. The physical model used in this study was derived based on an actual rubble mound in Busan Yacht Harbor. This research attempts to fill the gap in practical knowledge on the combined effect of the armor roughness and vertical wall on wave overtopping in rubble mound breakwaters. The main governing parameters used in this study were the vertical wall height, variation of the tetrapod weights, initial water level elevation, and the volume of overtopping under constant wave properties. The experimental results showed that the roughness factor differed according to the tetrapod size. Furthermore, the overtopping discharge with no vertical wall was similar to that with relatively short vertical walls ( 1 γv = 1). Therefore, the experimental results highlight the importance of the height of the vertical wall in reducing overtopping discharge. Moreover, a large tetrapod size may allow coastal engineers to choose a shorter vertical wall to save cost, while obtaining better performance.

  12. Vertical gaze angle: absolute height-in-scene information for the programming of prehension.

    PubMed

    Gardner, P L; Mon-Williams, M

    2001-02-01

    One possible source of information regarding the distance of a fixated target is provided by the height of the object within the visual scene. It is accepted that this cue can provide ordinal information, but generally it has been assumed that the nervous system cannot extract "absolute" information from height-in-scene. In order to use height-in-scene, the nervous system would need to be sensitive to ocular position with respect to the head and to head orientation with respect to the shoulders (i.e. vertical gaze angle or VGA). We used a perturbation technique to establish whether the nervous system uses vertical gaze angle as a distance cue. Vertical gaze angle was perturbed using ophthalmic prisms with the base oriented either up or down. In experiment 1, participants were required to carry out an open-loop pointing task whilst wearing: (1) no prisms; (2) a base-up prism; or (3) a base-down prism. In experiment 2, the participants reached to grasp an object under closed-loop viewing conditions whilst wearing: (1) no prisms; (2) a base-up prism; or (3) a base-down prism. Experiment 1 and 2 provided clear evidence that the human nervous system uses vertical gaze angle as a distance cue. It was found that the weighting attached to VGA decreased with increasing target distance. The weighting attached to VGA was also affected by the discrepancy between the height of the target, as specified by all other distance cues, and the height indicated by the initial estimate of the position of the supporting surface. We conclude by considering the use of height-in-scene information in the perception of surface slant and highlight some of the complexities that must be involved in the computation of environmental layout.

  13. Vertical ridge augmentation using xenogenous bone blocks: a comparison between the flap and tunneling procedures.

    PubMed

    Xuan, Feng; Lee, Chun-Ui; Son, Jeong-Seog; Fang, Yiqin; Jeong, Seung-Mi; Choi, Byung-Ho

    2014-09-01

    Previous studies have shown that the subperiosteal tunneling procedure in vertical ridge augmentation accelerates healing after grafting and prevents graft exposure, with minor postoperative complications. It is conceivable that new bone formation would be greater with the tunneling procedure than with the flap procedure, because the former is minimally invasive. This hypothesis was tested in this study by comparing new bone formation between the flap and tunneling procedures after vertical ridge augmentation using xenogenous bone blocks in a canine mandible model. Two Bio-Oss blocks were placed on the edentulous ridge in each side of the mandibles of 6 mongrel dogs. The blocks in each side were randomly assigned to grafting with a flap procedure (flap group) or grafting with a tunneling procedure (tunneling group). The mean percentage of newly formed bone within the block was 15.3 ± 6.6% in the flap group and 46.6 ± 23.4% in the tunneling group. Based on data presented in this study, when a tunneling procedure is used to place xenogenous bone blocks for vertical ridge augmentation, bone formation in the graft sites is significantly greater than when a flap procedure is used. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Stress distribution of endodontically treated teeth with titanium alloy post and carbon fiber post with different alveolar bone height: A three-dimensional finite element analysis.

    PubMed

    Singh, S Vijay; Bhat, Manohar; Gupta, Saurabh; Sharma, Deepak; Satija, Harsha; Sharma, Sumeet

    2015-01-01

    A three-dimensional (3D) finite element analysis (FEA) on the stress distribution of endodontically treated teeth with titanium alloy post and carbon fiber post with different alveolar bone height. The 3D model was fabricated using software to represent an endodontically treated mandibular second premolar with post and restored with a full ceramic crown restoration, which was then analyzed using FEA using FEA ANSYS Workbench V13.0 (ANSYS Inc., Canonsburg, Pennsylvania, U.S.A) software. The FEA showed the maximum stresses of 137.43 Mpa in dentin with alveolar bone height of 4 mm when the titanium post was used, 138.48 Mpa when carbon fiber post was used as compared to 105.91 Mpa in the model with alveolar bone height of 2 mm from the cement enamel junction (CEJ) when the titanium post was used and 107.37 Mpa when the carbon fiber post was used. Stress was observed more in alveolar bone height level of 4 mm from CEJ than 2 mm from CEJ. Stresses in the dentin were almost similar when the carbon fiber post was compared to titanium post. However, stresses in the post and the cement were much higher when titanium post was used as compared to carbon fiber post.

  15. Acute Effect of Foam Rolling and Dynamic Stretching on Flexibility and Jump Height.

    PubMed

    Smith, Jason C; Pridgeon, Brooke; Hall, MacGregor C

    2018-04-04

    Smith, JC, Pridgeon, B, and Hall, MC. Acute effect of foam rolling and dynamic stretching on flexibility and jump height. J Strength Cond Res XX(X): 000-000, 2017-Dynamic stretching (DS) can acutely improve vertical jump (VJ) performance but its effect lasts no more than 5 minutes. Foam rolling (FR), a form of self-myofascial release, can acutely increase range of motion (ROM) with this effect lasting less than 10 minutes. Therefore, the purpose of this study was to evaluate the time course of these effects, separately and combined, on VJ height and ROM. Twenty-nine university students completed 4 different sessions (control, FR, DS, and combo) in a randomized order. After a warm-up and baseline assessments of VJ height and sit-and-reach, participants rested (control) and performed FR, DS, and the combination of FR and DS (combo). Vertical jump height and ROM were assessed every 5 minutes for 20 minutes after treatment. Mean scores at each time point were expressed as a percent change from baseline scores. Immediately after FR, sit-and-reach was significantly greater than control (p = 0.003). Vertical jump height immediately after treatment for DS and combo was significantly greater than the control and FR counterparts (p ≤ 0.002). Vertical jump height for DS and combo was also significantly greater than the control counterpart at 5 minutes after treatment (p < 0.001). At 15 minutes after treatment, the percent change in VJ height for the combo was significantly greater than the control counterpart (p = 0.002). Although FR has no effect on VJ performance, it can acutely increase ROM, but its effect was quickly dissipated. Foam rolling does not seem to enhance VJ height either alone or in combination with DS.

  16. Strong correlation of maximal squat strength with sprint performance and vertical jump height in elite soccer players

    PubMed Central

    Wisloff, U; Castagna, C; Helgerud, J; Jones, R; Hoff, J

    2004-01-01

    Background: A high level of strength is inherent in elite soccer play, but the relation between maximal strength and sprint and jumping performance has not been studied thoroughly. Objective: To determine whether maximal strength correlates with sprint and vertical jump height in elite male soccer players. Methods: Seventeen international male soccer players (mean (SD) age 25.8 (2.9) years, height 177.3 (4.1) cm, weight 76.5 (7.6) kg, and maximal oxygen uptake 65.7 (4.3) ml/kg/min) were tested for maximal strength in half squats and sprinting ability (0–30 m and 10 m shuttle run sprint) and vertical jumping height. Result: There was a strong correlation between maximal strength in half squats and sprint performance and jumping height. Conclusions: Maximal strength in half squats determines sprint performance and jumping height in high level soccer players. High squat strength did not imply reduced maximal oxygen consumption. Elite soccer players should focus on maximal strength training, with emphasis on maximal mobilisation of concentric movements, which may improve their sprinting and jumping performance. PMID:15155427

  17. Assessment of vertical changes during maxillary expansion using quad helix or bonded rapid maxillary expander.

    PubMed

    Conroy-Piskai, Cara; Galang-Boquiren, Maria Therese S; Obrez, Ales; Viana, Maria Grace Costa; Oppermann, Nelson; Sanchez, Flavio; Edgren, Bradford; Kusnoto, Budi

    2016-11-01

    To determine if there is a significantly different effect on vertical changes during phase I palatal expansion treatment using a quad helix and a bonded rapid maxillary expander in growing skeletal Class I and Class II patients. This retrospective study looked at 2 treatment groups, a quad helix group and a bonded rapid maxillary expander group, before treatment (T1) and at the completion of phase I treatment (T2). Each treatment group was compared to an untreated predicted growth model. Lateral cephalograms at T1 and T2 were traced and analyzed for changes in vertical dimension. No differences were found between the treatment groups at T1, but significant differences at T2 were found for convexity, lower facial height, total facial height, facial axis, and Frankfort Mandibular Plane Angle (FMA) variables. A comparison of treatment groups at T2 to their respective untreated predicted growth models found a significant difference for the lower facial height variable in the quad helix group and for the upper first molar to palatal plane (U6-PP) variable in the bonded expander group. Overall, both the quad helix expander and the bonded rapid maxillary expander showed minimal vertical changes during palatal expansion treatment. The differences at T2 suggested that the quad helix expander had more control over skeletal vertical measurements. When comparing treatment results to untreated predicted growth values, the quad helix expander appeared to better maintain lower facial height and the bonded rapid maxillary expander appeared to better maintain the maxillary first molar vertical height.

  18. A Sensor Fusion Method for Tracking Vertical Velocity and Height Based on Inertial and Barometric Altimeter Measurements

    PubMed Central

    Sabatini, Angelo Maria; Genovese, Vincenzo

    2014-01-01

    A sensor fusion method was developed for vertical channel stabilization by fusing inertial measurements from an Inertial Measurement Unit (IMU) and pressure altitude measurements from a barometric altimeter integrated in the same device (baro-IMU). An Extended Kalman Filter (EKF) estimated the quaternion from the sensor frame to the navigation frame; the sensed specific force was rotated into the navigation frame and compensated for gravity, yielding the vertical linear acceleration; finally, a complementary filter driven by the vertical linear acceleration and the measured pressure altitude produced estimates of height and vertical velocity. A method was also developed to condition the measured pressure altitude using a whitening filter, which helped to remove the short-term correlation due to environment-dependent pressure changes from raw pressure altitude. The sensor fusion method was implemented to work on-line using data from a wireless baro-IMU and tested for the capability of tracking low-frequency small-amplitude vertical human-like motions that can be critical for stand-alone inertial sensor measurements. Validation tests were performed in different experimental conditions, namely no motion, free-fall motion, forced circular motion and squatting. Accurate on-line tracking of height and vertical velocity was achieved, giving confidence to the use of the sensor fusion method for tracking typical vertical human motions: velocity Root Mean Square Error (RMSE) was in the range 0.04–0.24 m/s; height RMSE was in the range 5–68 cm, with statistically significant performance gains when the whitening filter was used by the sensor fusion method to track relatively high-frequency vertical motions. PMID:25061835

  19. Effects of ethnicity on the relationship between vertical jump and maximal power on a cycle ergometer.

    PubMed

    Rouis, Majdi; Coudrat, Laure; Jaafar, Hamdi; Attiogbé, Elvis; Vandewalle, Henry; Driss, Tarak

    2016-06-01

    The aim of this study was to verify the impact of ethnicity on the maximal power-vertical jump relationship. Thirty-one healthy males, sixteen Caucasian (age: 26.3 ± 3.5 years; body height: 179.1 ± 5.5 cm; body mass: 78.1 ± 9.8 kg) and fifteen Afro-Caribbean (age: 24.4 ±2.6 years; body height: 178.9 ± 5.5 cm; body mass: 77.1 ± 10.3 kg) completed three sessions during which vertical jump height and maximal power of lower limbs were measured. The results showed that the values of vertical jump height and maximal power were higher for Afro-Caribbean participants (62.92 ± 6.7 cm and 14.70 ± 1.75 W∙kg-1) than for Caucasian ones (52.92 ± 4.4 cm and 12.75 ± 1.36 W∙kg-1). Moreover, very high reliability indices were obtained on vertical jump (e.g. 0.95 < ICC < 0.98) and maximal power performance (e.g. 0.75 < ICC < 0.97). However, multiple linear regression analysis showed that, for a given value of maximal power, the Afro-Caribbean participants jumped 8 cm higher than the Caucasians. Together, these results confirmed that ethnicity impacted the maximal power-vertical jump relationship over three sessions. In the current context of cultural diversity, the use of vertical jump performance as a predictor of muscular power should be considered with caution when dealing with populations of different ethnic origins.

  20. Effect of abutment height on interproximal implant bone level in the early healing: A randomized clinical trial.

    PubMed

    Blanco, Juan; Pico, Alexandre; Caneiro, Leticia; Nóvoa, Lourdes; Batalla, Pilar; Martín-Lancharro, Pablo

    2018-01-01

    The aim of this randomized clinical trial was to compare the effect on the interproximal implant bone loss (IBL) of two different heights (1 and 3 mm) of definitive abutments placed at bone level implants with a platform switched design. Twenty-two patients received forty-four implants (6.5-10 mm length and 3.5-4 mm diameter) to replace at least two adjacent missing teeth, one bridge set to each patient-two implants per bridge. Patients were randomly allocated, and two different abutment heights, 1 and 3 mm using only one abutment height per bridge, were used. Clinical and radiological measurements were performed at 3 and 6 months after surgery. Interproximal bone level changes were compared between treatment groups. The association between IBL and categorical variables (history of periodontitis, smoking, implant location, implant diameter, implant length, insertion torque, width of keratinized mucosa, bone density, gingival biotype and antagonist) was also performed. At 3 months, implants with a 1-mm abutment had significantly greater IBL (0.83 ± 0.19 mm) compared to implants with a 3-mm abutment (0.14 ± 0.08 mm). At 6 months, a greater IBL was observed at implants with 1-mm abutments compared to implants with 3-mm abutments (0.91 ± 0.19 vs. 0.11 ± 0.09 mm). The analysis of the relation between patient characteristics and clinical variables with IBL revealed no significant differences at any moment except for smoking. Abutment height is an important factor to maintain interproximal implant bone level in early healing. Short abutments led to a greater interproximal bone loss in comparison with long abutments after 6 months. Other variables except smoking showed no relation with interproximal bone loss in early healing. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Bone mineral density and correlation factor analysis in normal Taiwanese children.

    PubMed

    Shu, San-Ging

    2007-01-01

    Our aim was to establish reference data and linear regression equations for lumbar bone mineral density (BMD) in normal Taiwanese children. Several influencing factors of lumbar BMD were investigated. Two hundred fifty-seven healthy children were recruited from schools, 136 boys and 121 girls, aged 4-18 years were enrolled on a voluntary basis with written consent. Their height, weight, blood pressure, puberty stage, bone age and lumbar BMD (L2-4) by dual energy x-ray absorptiometry (DEXA) were measured. Data were analyzed using Pearson correlation and stepwise regression tests. All measurements increased with age. Prior to age 8, there was no gender difference. Parameters such as height, weight, and bone age (BA) in girls surpassed boys between ages 8-13 without statistical significance (p> or =0.05). This was reversed subsequently after age 14 in height (p<0.05). BMD difference had the same trend but was not statistically significant either. The influencing power of puberty stage and bone age over BMD was almost equal to or higher than that of height and weight. All the other factors correlated with BMD to variable powers. Multiple linear regression equations for boys and girls were formulated. BMD reference data is provided and can be used to monitor childhood pathological conditions. However, BMD in those with abnormal bone age or pubertal development could need modifications to ensure accuracy.

  2. Crestal sinus lift with sequential drills and simultaneous implant placement in sites with <5 mm of native bone: a multicenter retrospective study.

    PubMed

    Bernardello, Fabio; Righi, Davide; Cosci, Ferdinando; Bozzoli, Paolo; Soardi, Carlo Maria; Carlo, Maria Soardi; Spinato, Sergio

    2011-12-01

    The aim of this multicenter retrospective clinical study was to evaluate the survival rate of implants placed in the posterior maxilla with a residual bone height of <5 mm. One hundred seventeen patients, recruited from 6 different centers, had 134 implants placed below the maxillary sinus. The patient population consisted of 52 men and 65 women ranging in age from 39 to 78 years (mean age, 53.2 years). Sinus lift procedures were performed following a crestal approach using a specific sequence of drills (Cosci's technique). All implants were submerged. Periapical radiographs were obtained with a paralleling technique and were digitized. The pattern of bone remodeling was subsequently evaluated. The average (±SD) follow-up time was 48.2 months (±29.30 months; range, 24 to 120 months). Of the original 134 implants placed, 5 implants (3.7%) failed. The implant survival rate was 96.3%. The average residual bone height was 3.46 mm (±0.91 mm) at baseline. The average height of the alveolar crest in the treated implant sites was 9.94 ± 2.29 mm. The radiographic bone gain was 6.48 ± 2.38 mm. The investigation suggests that this crestal drill approach can be a successful sinus lifting procedure in a severe atrophic maxilla with <5 mm of crestal bone height.

  3. Alveolar ridge preservation with deproteinized bovine bone graft and collagen membrane and delayed implants.

    PubMed

    Pang, Chaoyuan; Ding, Yuxiang; Zhou, Hongzhi; Qin, Ruifeng; Hou, Rui; Zhang, Guoliang; Hu, Kaijin

    2014-09-01

    To evaluate clinically and radiographically an alveolar ridge, preservation technique with deproteinized bovine bone graft and absorbable collagen membrane and then restoration with delayed implants were done. The study included 30 patients. The trial group's sockets were filled with deproteinized bovine bone graft (Bio-Oss) and covered with absorbable collagen membrane (Bio-Gide). The control group's sockets healed without any treatment. Panoramic radiograph and computed tomography were taken immediately after graft and 3 and 6 months later to evaluate the height, width, and volume change of the alveolar ridge bone. Dental implants were inserted in all sockets at 6 months, and osseointegration condition was evaluated in the following 12 months. All sockets healed uneventfully. In the trial group, the mean (SD) height reduction of the alveolar ridge bone was 1.05 (0.24) mm at 3 months and 1.54 (0.25) mm at 6 months. The width reduction was 1.11 (0.13) mm at 3 months and 1.84 (0.35) mm at 6 months. Bone volume reduction was 193.79 (21.47) mm at 3 months and 262.06 (33.08) mm at 6 months. At the same trend, in the control group, the bone height reduction was 2.12 (0.15) mm at 3 months and 3.26 (0.29) mm at 6 months. The width reduction was 2.72 (0.19) mm at 3 months and 3.56 (0.28) mm at 6 months. Bone volume reduction was 252.19 (37.21) mm at 3 months and 342.32 (36.41) mm at 6 months. There was a significant difference in alveolar ridge bone height, width, and volume reduction in the 2 groups. The osseointegration condition had no significant difference between the 2 groups. This study suggested that the deproteinized bovine bone graft and absorbable collagen membrane were beneficial to preserve the alveolar ridge bone and had no influence on the osseointegration of delayed implant.

  4. 47 CFR 73.160 - Vertical plane radiation characteristics, f(θ).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., f(θ). (a) The vertical plane radiation characteristics show the relative field being radiated at a... the electrical height of the tower, not including the base insulator and pier. (In the case of a folded unipole tower, the entire radiating structure's electrical height is used.) (2) For a top-loaded...

  5. Concurrent validity of the Gyko inertial sensor system for the assessment of vertical jump height in female sub-elite youth soccer players.

    PubMed

    Lesinski, Melanie; Muehlbauer, Thomas; Granacher, Urs

    2016-01-01

    The aim of the present study was to verify concurrent validity of the Gyko inertial sensor system for the assessment of vertical jump height. Nineteen female sub-elite youth soccer players (mean age: 14.7 ± 0.6 years) performed three trials of countermovement (CMJ) and squat jumps (SJ), respectively. Maximal vertical jump height was simultaneously quantified with the Gyko system, a Kistler force-plate (i.e., gold standard), and another criterion device that is frequently used in the field, the Optojump system. Compared to the force-plate, the Gyko system determined significant systematic bias for mean CMJ (-0.66 cm, p  < 0.01, d  = 1.41) and mean SJ (-0.91 cm, p  < 0.01, d  = 1.69) height. Random bias was ± 3.2 cm for CMJ and ± 4.0 cm for SJ height and intraclass correlation coefficients (ICCs) were "excellent" (ICC = 0.87 for CMJ and 0.81 for SJ). Compared to the Optojump device, the Gyko system detected a significant systematic bias for mean CMJ (0.55 cm, p  < 0.05, d  = 0.94) but not for mean SJ (0.39 cm) height. Random bias was ± 3.3 cm for CMJ and ± 4.2 cm for SJ height and ICC values were "excellent" (ICC = 0.86 for CMJ and 0.82 for SJ). Consequently, apparatus specific regression equations were provided to estimate true vertical jump height for the Kistler force-plate and the Optojump device from Gyko-derived data. Our findings indicate that the Gyko system cannot be used interchangeably with a Kistler force-plate and the Optojump device in trained individuals. It is suggested that practitioners apply the correction equations to estimate vertical jump height for the force-plate and the Optojump system from Gyko-derived data.

  6. Endoscopically assisted tunnel approach for minimally invasive corticotomies: a preliminary report.

    PubMed

    Hernández-Alfaro, Federico; Guijarro-Martínez, Raquel

    2012-05-01

    The dental community has expressed low acceptance of traditional corticotomy techniques for corticotomy-facilitated orthodontics. These procedures are time consuming, entail substantial postoperative morbidity and periodontal risks, and are often perceived as highly invasive. A total of 114 interdental sites were treated in nine consecutive patients. Under local anesthesia, a tunnel approach requiring one to three vertical incisions per arch (depending on the targeted teeth) was used. Piezosurgical corticotomies and elective bone augmentation procedures were performed under endoscopic assistance. Postoperative cone-beam computerized tomography evaluation was used to confirm adequate corticotomy depth. Procedures were completed in a mean time of 26 minutes. Follow-up evaluations revealed no loss of tooth vitality, no changes in periodontal probing depth, good preservation of the papillae, and no gingival recession. No evidence of crestal bone height reduction or apical root resorption was detected. The tunnel approach minimizes soft-tissue debridement and permits effective cortical cuts. The combination of piezosurgery technique with endoscopic assistance provides a quick, reliable means to design and perform these corticotomies while maximizing root integrity preservation. Moreover, the sites needing bone augmentation are selected under direct vision. Compared to traditional corticotomies, this procedure has manifest advantages in surgical time, technical complexity, patient morbidity, and periodontium preservation.

  7. Clinical outcome of alveolar ridge augmentation with individualized CAD-CAM-produced titanium mesh.

    PubMed

    Sagheb, K; Schiegnitz, E; Moergel, M; Walter, C; Al-Nawas, B; Wagner, W

    2017-12-01

    The augmentation of the jaw has been and continues to be a sophisticated therapy in implantology. Modern CAD-CAM technologies lead to revival of old and established augmentation techniques such as the use of titanium mesh (TM) for bone augmentation. The aim of this retrospective study was to evaluate the clinical outcome of an individualized CAD-CAM-produced TM based on the CT/DVT-DICOM data of the patients for the first time. In 17 patients, 21 different regions were augmented with an individualized CAD-CAM-produced TM (Yxoss CBR®, Filderstadt, Germany). For the augmentation, a mixture of autologous bone and deproteinized bovine bone mineral (DBBM) or autologous bone alone was used. Reentry with explantation of the TM and simultaneous implantation of 44 implants were performed after 6 months. Preoperative and 6-month postoperative cone beam computed tomographies (CBCT) were performed to measure the gained bone height. The success rate for the bone grafting procedure was 100%. Thirty-three percent of cases presented an exposure of the TM during the healing period. However, premature removal of these exposed meshes was not necessary. Exposure rate in augmentations performed with mid-crestal incisions was higher than in augmentations performed with a modified poncho incision (45.5 vs. 20%, p = 0.221). In addition, exposure rates in the maxilla were significantly higher than in the mandible (66.7 vs. 8.3%, p = 0.009). Gender, smoking, periodontal disease, gingiva type, used augmentation material, and used membrane had no significant influence on the exposure rate (p > 0.05). The mean vertical augmentation was 6.5 ± 1.7 mm, and the mean horizontal augmentation was 5.5 ± 1.9 mm. Implant survival rate after a mean follow-up of 12 ± 6 months after reentry was 100%. Within the limits of the retrospective character of this study, this study shows for the first time that individualized CAD-CAM TM provide a sufficient and safe augmentation technique, especially for vertical and combined defects. However, the soft tissue handling for sufficient mesh covering remains one of the most critical steps using this technique.

  8. Boys with a simple delayed puberty reach their target height.

    PubMed

    Cools, B L M; Rooman, R; Op De Beeck, L; Du Caju, M V L

    2008-01-01

    Final height in boys with delayed puberty is thought to be below target height. This conclusion, however, is based on studies that included patients with genetic short stature. We therefore studied final height in a group of 33 untreated boys with delayed puberty with a target height >-1.5 SDS. Standing height, sitting height, weight and arm span width were measured in each patient. Final height was predicted by the method of Greulich and Pyle using the tables of Bailey and Pinneau for retarded boys at their bone age (PAH1) and the tables of Bailey and Pinneau for average boys plus six months (PAH2). Mean final height (175.8 +/- 6.5 cm) was appropriate for the mean target height (174.7 +/- 4.5 cm). The prediction method of Bailey and Pinneau overestimated the final height by 1.4 cm and the modified prediction method slightly underestimated the final height (-0.15 cm). Boys with untreated delayed puberty reach a final height appropriate for their target height. Final height was best predicted by the method of Bailey and Pinneau using the tables for average boys at their bone age plus six months. Copyright 2008 S. Karger AG, Basel.

  9. Assessment of morphological and anatomical characteristics of mental foramen using cone beam computed tomography.

    PubMed

    Goyushov, Samir; Tözüm, Melek Didem; Tözüm, Tolga Fikret

    2018-05-25

    To determine the shape, position, vertical height, surrounding bone characteristics, and opening angle of mental foramen (MF) using dental cone beam computed tomography (CBCT). A retrospective study was performed on 663 patients. CBCT records analyzed for the shape, position, and surrounding bone measurements of the MF using Simplant 3D software (Hasselt, Belgium). Opening angle of MF was also assessed. Kruskal-Wallis and Mann-Whitney U tests were employed to test significant differences between parameters, genders and ages. All mental foramina were visualized. Regarding location, 49.2% of the MFs were located between first and second premolars, 7.7 distal and 39.7% coincident to the apex of the mandibular second premolar. The mean MF opening angle was 45.4° on the right side, and 45.9° on the left. There were no statistically differences between gender groups with regard to the opening angle degrees. This study may provide useful information about variations in the position, shape and size, angle of mental foramen, which may help the practitioners to perform safer mental nerve blocks and surgical procedures.

  10. Vertical cross-spectral phases in atmospheric flow

    NASA Astrophysics Data System (ADS)

    Chougule, A.; Mann, J.; Kelly, M.

    2014-11-01

    The cross-spectral phases between velocity components at two heights are analyzed from observations at the Høvsøre test site under diabatic conditions. These phases represent the degree to which turbulence sensed at one height leads (or lags) in time the turbulence sensed at the other height. The phase angle of the cross-wind component is observed to be significantly greater than the phase for the along-wind component, which in turn is greater than the phase for the vertical component. The cross-wind and along-wind phases increase with stream-wise wavenumber and vertical separation distance, but there is no significant change in the phase angle of vertical velocity. The phase angles for all atmospheric stabilities show similar order in phasing. The phase angles from the Høvsøre observations under neutral condition are compared with a rapid distortion theory model which show similar order in phase shift.

  11. Experimental test of theory for the stability of partially saturated vertical cut slopes

    USGS Publications Warehouse

    Morse, Michael M.; Lu, N.; Wayllace, Alexandra; Godt, Jonathan W.; Take, W.A.

    2014-01-01

    This paper extends Culmann's vertical-cut analysis to unsaturated soils. To test the extended theory, unsaturated sand was compacted to a uniform porosity and moisture content in a laboratory apparatus. A sliding door that extended the height of the free face of the slope was lowered until the vertical cut failed. Digital images of the slope cross section and upper surface were acquired concurrently. A recently developed particle image velocimetry (PIV) tool was used to quantify soil displacement. The PIV analysis showed strain localization at varying distances from the sliding door prior to failure. The areas of localized strain were coincident with the location of the slope crest after failure. Shear-strength and soil-water-characteristic parameters of the sand were independently tested for use in extended analyses of the vertical-cut stability and of the failure plane angle. Experimental failure heights were within 22.3% of the heights predicted using the extended theory.

  12. Measurement errors when estimating the vertical jump height with flight time using photocell devices: the example of Optojump.

    PubMed

    Attia, A; Dhahbi, W; Chaouachi, A; Padulo, J; Wong, D P; Chamari, K

    2017-03-01

    Common methods to estimate vertical jump height (VJH) are based on the measurements of flight time (FT) or vertical reaction force. This study aimed to assess the measurement errors when estimating the VJH with flight time using photocell devices in comparison with the gold standard jump height measured by a force plate (FP). The second purpose was to determine the intrinsic reliability of the Optojump photoelectric cells in estimating VJH. For this aim, 20 subjects (age: 22.50±1.24 years) performed maximal vertical jumps in three modalities in randomized order: the squat jump (SJ), counter-movement jump (CMJ), and CMJ with arm swing (CMJarm). Each trial was simultaneously recorded by the FP and Optojump devices. High intra-class correlation coefficients (ICCs) for validity (0.98-0.99) and low limits of agreement (less than 1.4 cm) were found; even a systematic difference in jump height was consistently observed between FT and double integration of force methods (-31% to -27%; p<0.001) and a large effect size (Cohen's d >1.2). Intra-session reliability of Optojump was excellent, with ICCs ranging from 0.98 to 0.99, low coefficients of variation (3.98%), and low standard errors of measurement (0.8 cm). It was concluded that there was a high correlation between the two methods to estimate the vertical jump height, but the FT method cannot replace the gold standard, due to the large systematic bias. According to our results, the equations of each of the three jump modalities were presented in order to obtain a better estimation of the jump height.

  13. Measurement errors when estimating the vertical jump height with flight time using photocell devices: the example of Optojump

    PubMed Central

    Attia, A; Chaouachi, A; Padulo, J; Wong, DP; Chamari, K

    2016-01-01

    Common methods to estimate vertical jump height (VJH) are based on the measurements of flight time (FT) or vertical reaction force. This study aimed to assess the measurement errors when estimating the VJH with flight time using photocell devices in comparison with the gold standard jump height measured by a force plate (FP). The second purpose was to determine the intrinsic reliability of the Optojump photoelectric cells in estimating VJH. For this aim, 20 subjects (age: 22.50±1.24 years) performed maximal vertical jumps in three modalities in randomized order: the squat jump (SJ), counter-movement jump (CMJ), and CMJ with arm swing (CMJarm). Each trial was simultaneously recorded by the FP and Optojump devices. High intra-class correlation coefficients (ICCs) for validity (0.98-0.99) and low limits of agreement (less than 1.4 cm) were found; even a systematic difference in jump height was consistently observed between FT and double integration of force methods (-31% to -27%; p<0.001) and a large effect size (Cohen’s d>1.2). Intra-session reliability of Optojump was excellent, with ICCs ranging from 0.98 to 0.99, low coefficients of variation (3.98%), and low standard errors of measurement (0.8 cm). It was concluded that there was a high correlation between the two methods to estimate the vertical jump height, but the FT method cannot replace the gold standard, due to the large systematic bias. According to our results, the equations of each of the three jump modalities were presented in order to obtain a better estimation of the jump height. PMID:28416900

  14. Visual exploration during locomotion limited by fear of heights.

    PubMed

    Kugler, Günter; Huppert, Doreen; Eckl, Maria; Schneider, Erich; Brandt, Thomas

    2014-01-01

    Visual exploration of the surroundings during locomotion at heights has not yet been investigated in subjects suffering from fear of heights. Eye and head movements were recorded separately in 16 subjects susceptible to fear of heights and in 16 non-susceptible controls while walking on an emergency escape balcony 20 meters above ground level. Participants wore mobile infrared eye-tracking goggles with a head-fixed scene camera and integrated 6-degrees-of-freedom inertial sensors for recording head movements. Video recordings of the subjects were simultaneously made to correlate gaze and gait behavior. Susceptibles exhibited a limited visual exploration of the surroundings, particularly the depth. Head movements were significantly reduced in all three planes (yaw, pitch, and roll) with less vertical head oscillations, whereas total eye movements (saccade amplitudes, frequencies, fixation durations) did not differ from those of controls. However, there was an anisotropy, with a preference for the vertical as opposed to the horizontal direction of saccades. Comparison of eye and head movement histograms and the resulting gaze-in-space revealed a smaller total area of visual exploration, which was mainly directed straight ahead and covered vertically an area from the horizon to the ground in front of the feet. This gaze behavior was associated with a slow, cautious gait. The visual exploration of the surroundings by susceptibles to fear of heights differs during locomotion at heights from the earlier investigated behavior of standing still and looking from a balcony. During locomotion, anisotropy of gaze-in-space shows a preference for the vertical as opposed to the horizontal direction during stance. Avoiding looking into the abyss may reduce anxiety in both conditions; exploration of the "vertical strip" in the heading direction is beneficial for visual control of balance and avoidance of obstacles during locomotion.

  15. Adiposity and TV viewing are related to less bone accrual in young children.

    PubMed

    Wosje, Karen S; Khoury, Philip R; Claytor, Randal P; Copeland, Kristen A; Kalkwarf, Heidi J; Daniels, Stephen R

    2009-01-01

    To examine the relation between baseline fat mass and gain in bone area and bone mass in preschoolers studied prospectively for 4 years, with a focus on the role of physical activity and TV viewing. Children were part of a longitudinal study in which measures of fat, lean and bone mass, height, weight, activity, and diet were taken every 4 months from ages 3 to 7 years. Activity was measured by accelerometer and TV viewing by parent checklist. We included 214 children with total body dual energy x-ray absorptiometry (Hologic 4500A) scans at ages 3.5 and 7 years. Higher baseline fat mass was associated with smaller increases in bone area and bone mass over the next 3.5 years (P < .001). More TV viewing was related to smaller gains in bone area and bone mass accounting for race, sex, and height. Activity by accelerometer was not associated with bone gains. Adiposity and TV viewing are related to less bone accrual in preschoolers.

  16. Validity and reliability of the Myotest accelerometric system for the assessment of vertical jump height.

    PubMed

    Casartelli, Nicola; Müller, Roland; Maffiuletti, Nicola A

    2010-11-01

    The aim of the present study was to verify the validity and reliability of the Myotest accelerometric system (Myotest SA, Sion, Switzerland) for the assessment of vertical jump height. Forty-four male basketball players (age range: 9-25 years) performed series of squat, countermovement and repeated jumps during 2 identical test sessions separated by 2-15 days. Flight height was simultaneously quantified with the Myotest system and validated photoelectric cells (Optojump). Two calculation methods were used to estimate the jump height from Myotest recordings: flight time (Myotest-T) and vertical takeoff velocity (Myotest-V). Concurrent validity was investigated comparing Myotest-T and Myotest-V to the criterion method (Optojump), and test-retest reliability was also examined. As regards validity, Myotest-T overestimated jumping height compared to Optojump (p < 0.001) with a systematic bias of approximately 7 cm, even though random errors were low (2.7 cm) and intraclass correlation coefficients (ICCs) where high (>0.98), that is, excellent validity. Myotest-V overestimated jumping height compared to Optojump (p < 0.001), with high random errors (>12 cm), high limits of agreement ratios (>36%), and low ICCs (<0.75), that is, poor validity. As regards reliability, Myotest-T showed high ICCs (range: 0.92-0.96), whereas Myotest-V showed low ICCs (range: 0.56-0.89), and high random errors (>9 cm). In conclusion, Myotest-T is a valid and reliable method for the assessment of vertical jump height, and its use is legitimate for field-based evaluations, whereas Myotest-V is neither valid nor reliable.

  17. In vitro comparison of the effect of different slice thicknesses on the accuracy of linear measurements on cone beam computed tomography images in implant sites.

    PubMed

    Shokri, Abbas; Khajeh, Samira

    2015-01-01

    Use of dental implants in edentulous patients has become a common treatment modality. Treatment of such implants requires radiographic evaluation, and in most cases, several different imaging techniques are necessary to evaluate the height, width, and structure of the bone at the implant site. In the current study, an attempt was made to evaluate the accuracy of measurements on cone beam computed tomography (CBCT) images with different slice thicknesses so that accurate data can be collected for proper clinical applications. In the present in vitro study, 11 human dry mandibles were used. The width and height of bone at the central, canine, and molar teeth areas were measured on the left and right sides by using digital calipers (as gold standard) and on CBCT images with 0.5-, 1-, 2-, 3-, 5-, and 10-mm slice thicknesses. Data were analyzed with SPSS 16, using paired t-test, Tukey test, and inter class correlation. Data were collected by evaluation of 11 skulls and 63 samples on the whole. There were no significant differences in bone width in any area (P > 0.05). There were significant differences in bone height in the central and molar teeth areas (P = 0.02). The measurements were not significant only at 4-mm slice thickness option and 5-mm slice thickness option for height compared with the gold standard (P = 0.513 and 0.173, respectively). The results did not show any significant differences between the observers (P = 0.329). The highest measurement accuracy of CBCT software program was observed at 4-mm slices for bone width and 5-mm slice thickness for bone height.

  18. Separate Vertical Wirings for the Extra-articular Fractures of the Distal Pole of the Patella.

    PubMed

    Kim, Young Mo; Yang, Jun Young; Kim, Kyung Cheon; Kang, Chan; Joo, Yong Bum; Lee, Woo Yong; Hwang, Jung Mo

    2011-12-01

    To evaluate the usefulness of separate vertical wirings for extra-articular fracture of distal pole of patella. We have analyzed the clinical results of 18 cases that underwent separate vertical wirings for extra-articular fracture of distal pole of the patella from March 2005 to March 2010, by using the range of motion and Bostman score. Occurrence of complication was also evaluated. Additionally, by taking simple radiographs, the correlation between the postoperative degree of anterior transposition of bone fragment and the time of bone fusion, preoperative length of bone fragment, and occurrence of comminuted fracture were investigated. It took an average of 13.8 weeks for radiological bone union after separate vertical wiring fixation. Flexion contracture was an average of 0.8 degrees and further flexion was an average of 127.6°, and Bostman score was an average of 27.5 points (excellent in 12 cases, and good in 6 cases). On the first postoperative year, average flexion contracture was 0.6 degrees and further flexion was an average of 136.3°, which exhibited increased joint motion and recovery to normal range of motion, and Bostman score was an average of 28.7 points (excellent in 16 cases, and good in 2 cases). There was no statistically significant difference between the preoperative bone fragment length and presence of comminution, and degree of anterior transposition of bone fragment after fracture union on simple radiograph (p=0.175, p=0.146). We were able to obtain satisfactory clinical results, while preserving the bone fragment by separate vertical wiring fixation for extra-articular fracture of distal pole of patella. Moreover, the method is easy to perform, which is also considered as a useful surgical method for extra-articular fracture of distal pole of patella.

  19. Partially Biodegradable Distraction Implant to Replace Conventional Implants in Alveolar Bone of Insufficient Height: A Preliminary Study in Dogs.

    PubMed

    Li, Tao; Zhang, Yongqiang; Shao, Bo; Gao, Yuan; Zhang, Chen; Cao, Qiang; Kong, Liang

    2015-12-01

    Dental implants have been widely used in the last few decades. However, patients with insufficient bone height need reconstructive surgeries before implant insertion. The distraction implant (DI) has been invented to simplify the treatment procedure, but the shortcomings of DIs have limited their clinical use. We incorporated biodegradable polyester into a novel DI called the partially biodegradable distraction implant (PBDI). The purpose of this study was to assess the radiological, histological, and biomechanical properties of the PBDI in animal models. PBDIs were manufactured and inserted into the atrophied mandibles of nine dogs. Box-shaped alveolar bones were segmented and distracted. The dogs were randomly divided into three groups that were sacrificed 1, 2, and 3 months after the implant insertion. Actual augmentation height (AAH) of the bone segments was measured to evaluate the effect of distraction. X-ray examination and micro-CT reconstruction and analysis were used to evaluate the regenerated bone in the distraction gap and bone around the functional element. Histological sections were used to evaluate the osseointegration and absorption of the PBDI. Fatigue tests were used to evaluate the biomechanical properties of the PBDI. Little change was found in AAH among the three groups. X-ray examination and micro-CT reconstruction showed good growth of regenerated bone in the distraction gap. Alveolar bone volume around the functional element increased steadily. No obvious bone absorption occurred in the alveolar crest around PBDI. Three months after distraction, the functional element achieved osseointegration, and the support element began to be absorbed. All PBDIs survived the fatigue test. The PBDI is a novel and reliable dental implant. It becomes a conventional implant after the absorption of the support element and the removal of the distraction screw. It is a promising replacement for conventional implants in patients with insufficient alveolar bone height. © 2014 Wiley Periodicals, Inc.

  20. Insulin Resistance Negatively Influences the Muscle-Dependent IGF-1-Bone Mass Relationship in Premenarcheal Girls.

    PubMed

    Kindler, J M; Pollock, N K; Laing, E M; Jenkins, N T; Oshri, A; Isales, C; Hamrick, M; Lewis, R D

    2016-01-01

    IGF-1 promotes bone growth directly and indirectly through its effects on skeletal muscle. Insulin and IGF-1 share a common cellular signaling process; thus, insulin resistance may influence the IGF-1-muscle-bone relationship. We sought to determine the effect of insulin resistance on the muscle-dependent relationship between IGF-1 and bone mass in premenarcheal girls. This was a cross-sectional study conducted at a university research center involving 147 girls ages 9 to 11 years. Glucose, insulin, and IGF-1 were measured from fasting blood samples. Homeostasis model assessment of insulin resistance (HOMA-IR) was calculated from glucose and insulin. Fat-free soft tissue (FFST) mass and bone mineral content (BMC) were measured by dual-energy x-ray absorptiometry. Our primary outcome was BMC/height. In our path model, IGF-1 predicted FFST mass (b = 0.018; P = .001), which in turn predicted BMC/height (b = 0.960; P < .001). IGF-1 predicted BMC/height (b = 0.001; P = .002), but not after accounting for the mediator of this relationship, FFST mass. The HOMA-IR by IGF-1 interaction negatively predicted FFST mass (b = -0.044; P = .034). HOMA-IR had a significant and negative effect on the muscle-dependent relationship between IGF-1 and BMC/height (b = -0.151; P = .047). Lean body mass is an important intermediary factor in the IGF-1-bone relationship. For this reason, bone development may be compromised indirectly via suboptimal IGF-1-dependent muscle development in insulin-resistant children.

  1. Immediate changes in spinal height and pain after aquatic vertical traction in patients with persistent low back symptoms: a crossover clinical trial.

    PubMed

    Simmerman, Susanne M; Sizer, Phillip S; Dedrick, Gregory S; Apte, Gail G; Brismée, Jean-Michel

    2011-05-01

    To investigate the effect of aquatic vertical traction on spinal height, pain intensity, and centralization response compared with a land-based supine flexion position for patients with low back pain and signs of nerve root compression. Single-blind, repeated-measures crossover design. Outpatient physical therapy clinic. Ninety-eight subjects were recruited using consecutive sampling, with 28 men and 32 women of a mean ± standard deviation (SD) age of 59.6 ± 11.6 years completing testing. Each subject participated in 2 sessions that consisted of loaded walking for 15 minutes, followed by either 15 minutes of land-based supine position or 15 minutes of aquatic vertical traction. Spinal height change, measured using a commercial stadiometer, was determined after completing loaded walking and after each intervention. The mean ± SD height change of 4.99 ± 2.88 mm after aquatic vertical traction was similar to that of 4.21 ± 2.53 mm after the land-based supine flexion (P = .0969). Paired t-test indicated that both interventions resulted in significant increased height (P < .0001). Decreases in pain after aquatic intervention (2.7 ± 2.1 cm) were significantly greater than decreases after land intervention (1.7 ± 1.7 cm; P = .0034), and centralization of symptoms was more pronounced after aquatic vertical suspension compared with the supine land-based flexion condition (P < .0001). A significant correlation between height change and both pain reduction (r = 0.39; P = .001) and centralization (r = 0.29; P = .013) was observed for the aquatic intervention only. Although both the aquatic and land interventions produced significant increases in overall spinal height, the aquatic intervention produced greater pain relief and centralization response in subjects with low back pain and signs of nerve root compression. Copyright © 2011 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  2. Measurement of the vertical gradient of the semidiurnal tidal wind phase in winter at the 95 km level

    NASA Astrophysics Data System (ADS)

    Schminder, R.; Kurschner, D.

    1984-05-01

    When supplemented by absolute reflection height measurements, low frequency wind measurements in the 90-100 km height range become truly competitive in comparison with the more widely used radar meteor wind observations. For example, height profiles of the wind parameters in the so-called meteor zone can be obtained due to the considerable interdiurnal variability of the average nighttime reflection heights controlled by geomagnetic activity. The phase of the semidiurnal tidal wind is particularly height-dependent. The measured vertical gradient of 1/4 h/km in winter corresponds to a vertical wavelength of about 50 km. Wind measurements in the upper atmosphere, at heights between 90 and 100 km, were carried out at the Collm Geophysical Observatory of Karl Marx University Leipzig for a number of years. These measurements use the closely-spaced receiver method and three measuring paths, on 179, 227, and 272 kHz. They take place every day between sunset and sunrise, i.e., nightly. A night in this sense may last as long as 18 hours in winter. Both the measurements and their evaluation are completely automatic, and the prevailing winds and tides are separated.

  3. Measurement of the Vertical Gradient of the Semidiurnal Tidal Wind Phase in Winter at the 95 Km Level

    NASA Technical Reports Server (NTRS)

    Schminder, R.; Kurschner, D.

    1984-01-01

    When supplemented by absolute reflection height measurements, low frequency wind measurements in the 90-100 km height range become truly competitive in comparison with the more widely used radar meteor wind observations. For example, height profiles of the wind parameters in the so-called meteor zone can be obtained due to the considerable interdiurnal variability of the average nighttime reflection heights controlled by geomagnetic activity. The phase of the semidiurnal tidal wind is particularly height-dependent. The measured vertical gradient of 1/4 h/km in winter corresponds to a vertical wavelength of about 50 km. Wind measurements in the upper atmosphere, at heights between 90 and 100 km, were carried out at the Collm Geophysical Observatory of Karl Marx University Leipzig for a number of years. These measurements use the closely-spaced receiver method and three measuring paths, on 179, 227, and 272 kHz. They take place every day between sunset and sunrise, i.e., nightly. A night in this sense may last as long as 18 hours in winter. Both the measurements and their evaluation are completely automatic, and the prevailing winds and tides are separated.

  4. Vertical Jump and Leg Power Norms for Young Adults

    ERIC Educational Resources Information Center

    Patterson, David D.; Peterson, D. Fred

    2004-01-01

    Medical students and their spouses (N = 724) served as participants to create norm-referenced vertical jump values for active, healthy people ages 21-30. All tests were conducted and measured by the same individual during a campus fitness evaluation using a Vertec[TM] apparatus. Jump height was measured to the nearest 0.5 in. Mean jump height was…

  5. Section Height Determination Methods of the Isotopographic Surface in a Complex Terrain Relief

    ERIC Educational Resources Information Center

    Syzdykova, Guldana D.; Kurmankozhaev, Azimhan K.

    2016-01-01

    A new method for determining the vertical interval of isotopographic surfaces on rugged terrain was developed. The method is based on the concept of determining the differentiated size of the vertical interval using spatial-statistical properties inherent in the modal characteristic, the degree of variability of apical heights and the chosen map…

  6. Interpreting Observations of Large-Scale Traveling Ionospheric Disturbances by Ionospheric Sounders

    NASA Astrophysics Data System (ADS)

    Pederick, L. H.; Cervera, M. A.; Harris, T. J.

    2017-12-01

    From July to October 2015, the Australian Defence Science and Technology Group conducted an experiment during which a vertical incidence sounder (VIS) was set up at Alice Springs Airport. During September 2015 this VIS observed the passage of many large-scale traveling ionospheric disturbances (TIDs). By plotting the measured virtual heights across multiple frequencies as a function of time, the passage of the TID can be clearly displayed. Using this plotting method, we show that all the TIDs observed during the campaign by the VIS at Alice Springs show an apparent downward phase progression of the crests and troughs. The passage of the TID can be more clearly interpreted by plotting the true height of iso-ionic contours across multiple plasma frequencies; the true heights can be obtained by inverting each ionogram to obtain an electron density profile. These plots can be used to measure the vertical phase speed of a TID and also reveal a time lag between events seen in true height compared to virtual height. To the best of our knowledge, this style of analysis has not previously been applied to other swept-frequency sounder observations. We develop a simple model to investigate the effect of the passage of a large-scale TID on a VIS. The model confirms that for a TID with a downward vertical phase progression, the crests and troughs will appear earlier in virtual height than in true height and will have a smaller apparent speed in true height than in virtual height.

  7. 14 CFR 77.17 - Obstruction standards.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... feet vertical distance. (2) 15 feet for any other public roadway. (3) 10 feet or the height of the... greater height than any of the following heights or surfaces: (1) A height of 499 feet AGL at the site of the object. (2) A height that is 200 feet AGL, or above the established airport elevation, whichever...

  8. 14 CFR 77.17 - Obstruction standards.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... feet vertical distance. (2) 15 feet for any other public roadway. (3) 10 feet or the height of the... greater height than any of the following heights or surfaces: (1) A height of 499 feet AGL at the site of the object. (2) A height that is 200 feet AGL, or above the established airport elevation, whichever...

  9. Vertical bone growth following autotransplantation of the developing maxillary third molar to replace a retained mandibular permanent molar: a case report.

    PubMed

    Plakwicz, Paweł; Czochrowska, Ewa Monika; Milczarek, Anna; Zadurska, Malgorzata

    2014-01-01

    A retained permanent mandibular first molar caused arrested development and a defect of the alveolar bone in a 16-year-old girl. Extraction of the ankylosed tooth was immediately followed by autotransplantation of the developing maxillary third molar. At the 3-year follow-up examination the interproximal bone level at the autotransplanted molar was equal to that of the neighboring teeth. Cone beam computed tomography showed bone at the labial aspect of the transplant. The eruption of the autotransplanted tooth stimulated vertical alveolar bone development and repaired the bone defect. Additionally, there was closure of the posterior open bite that was initially present at the ankylosed molar site.

  10. Systematic evaluation of a tissue-engineered bone for maxillary sinus augmentation in large animal canine model.

    PubMed

    Wang, Shaoyi; Zhang, Zhiyuan; Xia, Lunguo; Zhao, Jun; Sun, Xiaojuan; Zhang, Xiuli; Ye, Dongxia; Uludağ, Hasan; Jiang, Xinquan

    2010-01-01

    The objective of this study is to systematically evaluate the effects of a tissue-engineered bone complex for maxillary sinus augmentation in a canine model. Twelve sinus floor augmentation surgeries in 6 animals were performed bilaterally and randomly repaired with the following 3 groups of grafts: group A consisted of tissue-engineered osteoblasts/beta-TCP complex (n=4); group B consisted of beta-TCP alone (n=4); group C consisted of autogenous bone obtained from iliac crest as a positive control (n=4). All dogs had uneventful healings following the surgery. Sequential polychrome fluorescent labeling, maxillofacial CT, microhardness tests, as well as histological and histomorphometric analyses indicated that the tissue-engineered osteoblasts/beta-TCP complex dramatically promoted bone formation and mineralization and maximally maintained the height and volume of elevated maxillary sinus. By comparison, both control groups of beta-TCP or autologous iliac bone showed considerable resorption and replacement by fibrous or fatty tissue. We thus conclude that beta-TCP alone could barely maintain the height and volume of the elevated sinus floor, and that the transplantation of autogenous osteoblasts on beta-TCP could promote earlier bone formation and mineralization, maximally maintain height, volume and increase the compressive strength of augmented maxillary sinus. This tissue engineered bone complex might be a better alternative to autologous bone for the clinical edentulous maxillary sinus augmentation. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  11. Response to growth hormone treatment in Prader-Willi syndrome: auxological criteria versus genetic diagnosis.

    PubMed

    Scheermeyer, Elly; Hughes, Ian; Harris, Mark; Ambler, Geoff; Crock, Patricia; Verge, Charles F; Craig, Maria E; Bergman, Phil; Werther, George; van Driel, Mieke; Davies, Peter Sw; Choong, Catherine S Y

    2013-12-01

    The Australian Prader-Willi Syndrome (PWS) database was established to monitor the efficacy and safety of growth hormone (GH) treatment in PWS. This study aims to compare response to GH based on eligibility criteria. Comparative study: 72 children received GH on the basis of short stature or evidence of GH deficiency (pre-2009: PWS-SS) and 94 on a genetic diagnosis (post-2009: PWS-Dx). We report on mandatory patient data for GH prescription: median and standard deviation score (SDS) for height and body mass index (BMI), waist/height ratio, bone age/chronological age ratio and adverse events. Comparisons were made using non-parametric tests. At baseline, the PWS-SS cohort was shorter (height SDS: -2.6 vs. -1.1, P < 0.001), had a lower BMI (0.6 vs. 1.5 SDS, P < 0.05) and greater bone age delay (bone age/chronological age: 0.7 vs. 0.9, P < 0.05) than the PWS-Dx cohort. PWS-SS parents were shorter (mid-parental height SDS: -0.13 vs. 0.28, P < 0.005). Mean change in height over 2 years was 0.9 SDS and in BMI using PWS reference standards -0.3 SDSPWS (n = 106) (year 2, height SDS: PWS-SS = -1.7, PWS-Dx = 0.1; BMI SDSPWS : PWS-SS = -1.0, PWS-Dx = -0.6). The waist/height ratio reduced (PWS-Dx: 0.60 vs. 0.56, P < 0.05) and bone age delay was unchanged over this period. No serious adverse events were reported. The PWS-SS cohort represents a subgroup of the wider PWS-Dx population; however both cohorts improved height SDS with normalisation of height in the PWS-Dx cohort and lowering of BMI relative to PWS standards supporting the efficacy of treatment under the current Australian GH programme. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  12. Vertical Jump and Leg Power Normative Data for Colombian Schoolchildren Aged 9-17.9 Years: The FUPRECOL Study.

    PubMed

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge E; Lobelo, Felipe; Cadore, Eduardo L; Alonso-Martinez, Alicia M; Izquierdo, Mikel

    2017-04-01

    Ramírez-Vélez, R, Correa-Bautista, JE, Lobelo, F, Cadore, EL, Alonso-Martinez, AM, and Izquierdo, M. Vertical jump and leg power normative data for Colombian schoolchildren aged 9-17.9 years: the FUPRECOL study. J Strength Cond Res 31(4): 990-998, 2017-The aims of the present study were to generate normative vertical jump height and predicted peak power (Ppeak) data for 9- to 17.9-year-olds and to investigate between-sex and age group differences in these measures. This was a cross-sectional study of 7,614 healthy schoolchildren (boys n = 3,258 and girls n = 4,356, mean [SD] age 12.8 [2.3] years). Each participant performed 2 countermovement jumps; jump height was calculated using a Takei 5414 Jump-DF Digital Vertical (Takei Scientific Instruments Co., Ltd.). The highest jump was used for analysis and in the calculation of predicted Ppeak. Centile smoothed curves, percentiles, and tables for the 3rd, 10th, 25th, 50th, 75th, 90th, and 97th percentiles were calculated using Cole's LMS (L [curve Box-Cox], M [curve median], and S [curve coefficient of variation]) method. The 2-way analysis of variance tests showed that maximum jump height (in centimeters) and predicted Ppeak (in watts) were higher in boys than in girls (p < 0.01). Post hoc analyses within sexes showed yearly increases in jump height and Ppeak in all ages. In boys, the maximum jump height and predicted Ppeak 50th percentile ranged from 24.0 to 38.0 cm and from 845.5 to 3061.6 W, respectively. In girls, the 50th percentile for jump height ranged from 22.3 to 27.0 cm, and the predicted Ppeak was 710.1-2036.4 W. For girls, jump height increased yearly from 9 to 17.9 years old. Our results provide, for the first time, sex- and age-specific vertical jump height and predicted Ppeak reference standards for Colombian schoolchildren aged 9-17.9 years.

  13. Are there effects of age, gender, height, and body fat on the functional muscle-bone unit in children and adults?

    PubMed

    Duran, I; Martakis, K; Hamacher, S; Stark, C; Semler, O; Schoenau, E

    2018-05-01

    The aim was to describe the effect of age, gender, height, different stages of human life, and body fat on the functional muscle-bone unit. All these factors had a significant effect on the functional muscle-bone unit and should be addressed when assessing functional muscle-bone unit in children and adults. For the clinical evaluation of the functional muscle-bone unit, it was proposed to evaluate the adaptation of the bone to the acting forces. A frequently used parameter for this is the total body less head bone mineral content (TBLH-BMC) determined by dual-energy X-ray absorptiometry (DXA) in relation to the lean body mass (LBM by DXA). LBM correlates highly with muscle mass. Therefore, LBM is a surrogate parameter for the muscular forces acting in everyday life. The aim of the study was to describe the effect of age and gender on the TBLH-BMC for LBM and to evaluate the impact of other factors, such as height, different stages of human life, and of body fat. As part of the National Health and Nutrition Examination Survey (NHANES) study, between the years 1999-2006 whole-body DXA scans on randomly selected Americans from 8 years of age were carried out. From all eligible DXA scans (1999-2004), three major US ethnic groups were evaluated (non-Hispanic Whites, non-Hispanic Blacks, and Mexican Americans) for further statistical analysis. For the statistical analysis, the DXA scans of 8190 non-Hispanic White children and adults (3903 female), of 4931 non-Hispanic Black children and adults (2250 female) and 5421 of Mexican-American children and adults (2424 female) were eligible. Age, gender, body height, and especially body fat had a significant effect on the functional muscle-bone unit. When assessing TBLH-BMC for LBM in children and adults, the effects of age, gender, body fat, and body height should be addressed. These effects were analyzed for the first time in such a large cohort.

  14. Anthropometric adjustments are helpful in the interpretation of BMD and BMC Z-scores of pediatric patients with Prader-Willi syndrome.

    PubMed

    Hangartner, T N; Short, D F; Eldar-Geva, T; Hirsch, H J; Tiomkin, M; Zimran, A; Gross-Tsur, V

    2016-12-01

    Anthropometric adjustments of bone measurements are necessary in Prader-Willi syndrome patients to correctly assess the bone status of these patients. This enables physicians to get a more accurate diagnosis of normal versus abnormal bone, allow for early and effective intervention, and achieve better therapeutic results. Bone mineral density (BMD) is decreased in patients with Prader-Willi syndrome (PWS). Because of largely abnormal body height and weight, traditional BMD Z-scores may not provide accurate information in this patient group. The goal of the study was to assess a cohort of individuals with PWS and characterize the development of low bone density based on two adjustment models applied to a dataset of BMD and bone mineral content (BMC) from dual-energy X-ray absorptiometry (DXA) measurements. Fifty-four individuals, aged 5-20 years with genetically confirmed PWS, underwent DXA scans of spine and hip. Thirty-one of them also underwent total body scans. Standard Z-scores were calculated for BMD and BMC of spine and total hip based on race, sex, and age for all patients, as well as of whole body and whole-body less head for those patients with total-body scans. Additional Z-scores were generated based on anthropometric adjustments using weight, height, and percentage body fat and a second model using only weight and height in addition to race, sex, and age. As many PWS patients have abnormal anthropometrics, addition of explanatory variables weight, height, and fat resulted in different bone classifications for many patients. Thus, 25-70 % of overweight patients, previously diagnosed as normal, were subsequently diagnosed as below normal, and 40-60 % of patients with below-normal body height changed from below normal to normal depending on bone parameter. This is the first study to include anthropometric adjustments into the interpretation of BMD and BMC in children and adolescents with PWS. This enables physicians to get a more accurate diagnosis of normal versus abnormal BMD and BMC and allows for early and effective intervention.

  15. Alternative Distraction Osteogenesis Technique After Implant Placement for Alveolar Ridge Augmentation of the Maxilla.

    PubMed

    Nogueira, Renato Luiz Maia; Osterne, Rafael Lima Verde; Abreu, Ricardo Teixeira; Araújo, Phelype Maia

    2017-07-01

    An alternative technique to reconstruct atrophic alveolar vertical bone after implant placement is presented. The technique consists of distraction osteogenesis or direct surgical repositioning of an implant-and-bone block segment after segmental osteotomies that can be used in esthetic or unesthetic cases. Initially, casts indicating the implant position are obtained and the future ideal prosthetic position is determined to guide the model surgery. After the model surgery, a new provisional prosthesis is fabricated, and an occlusal splint, which is used as a surgical guide and a device for distraction osteogenesis, is custom fabricated. Then, the surgery is performed. For mobilization of the implant-and-bone block segment, 2 vertical osteotomies are performed and then joined by a horizontal osteotomy. The implant-and-bone block segment is moved to the planned position. If a small movement is planned, then the implant-and-bone segment is stabilized; for larger movements, the implant-and-bone segment can be gradually moved to the final position by distraction osteogenesis. This technique has good predictability of the final position of the implant-and-bone segment and relatively fast esthetic rehabilitation. It can be considered for dental implants in regions of vertical bone atrophy. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Crestal Sinus Augmentation with Recombinant Human Bone Morphogenetic Protein 2: Clinical and Radiographic Outcomes of 2-Year Pilot Trial.

    PubMed

    Kuchler, Ulrike; Rudelstorfer, Claudia M; Barth, Barbara; Tepper, Gabor; Lidinsky, Dominika; Heimel, Patrick; Watzek, Georg; Gruber, Reinhard

    Recombinant human bone morphogenetic protein 2 (rhBMP-2) together with an absorbable collagen carrier (ACS) was approved for augmentation of the maxillary sinus prior to implant placement. The original registration trial was based on a lateral window approach. Clinical outcomes of crestal sinus augmentation with rhBMP-2 have not been reported so far. An uncontrolled pilot trial in which seven patients with a residual maxillary height below 5 mm were enrolled to receive crestal sinus augmentation with rhBMP-2/ACS was conducted. Elevation of the sinus mucosa was performed by gel pressure. Primary endpoints were the gain in augmentation height and volume measured by computed tomography after 6 months. Evaluation of bone quality at the time of implant placement was based on histology. Secondary endpoints were the clinical and radiologic evaluation of the implants and patient satisfaction by visual analog scale (VAS) at the 2-year follow-up. Median gain in augmentation height was 7.2 mm (range 0.0 to 17.5 mm). Five patients gained at least 5 mm of bone height. Two patients with a perforation of the sinus mucosa failed to respond to rhBMP-2/ACS and underwent lateral window augmentation. The median gain in augmentation volume of the five patients was 781.3 mm³ (range 426.9 to 1,242.8 mm³). Biopsy specimens showed a cancellous network consisting of primary plexiform bone with little secondary lamellar bone. After 2 years, implants were in function with no signs of inflammation or peri-implant bone loss. Patients were satisfied with the esthetic outcomes and chewing function. This pilot clinical trial supports the original concept that rhBMP-2/ACS supports bone formation, also in crestal sinus augmentation, and emphasizes the relevance of the integrity of the sinus mucosa to predict the bone gain.

  17. Bone cement distribution is a potential predictor to the reconstructive effects of unilateral percutaneous kyphoplasty in OVCFs: a retrospective study.

    PubMed

    Lin, Jiachen; Qian, Lie; Jiang, Changqing; Chen, Xiuyuan; Feng, Fan; Lao, Lifeng

    2018-06-07

    Osteoporotic vertebral compression fracture (OVCF) is a common type of fracture, and percutaneous kyphoplasty (PKP) is an eligible solution to it. Previous studies have revealed that both the volume and filling pattern of bone cement correlate with the clinical outcomes after PKP procedure. However, the role of bone cement distribution remains to be illustrated. To retrospectively evaluate the relationship between the bone cement distribution and the clinical outcomes of unilateral PKP, we enrolled 73 OVCF patients receiving unilateral PKP treatment. All the intervened vertebrae were classified into three groups based on the bone cement distribution observed on postoperative X-ray films. Preoperative and postoperative radiographic parameters including the vertebral height and kyphotic Cobb angle were recorded, and anterior vertebral height restoration rate (AVHRR) and Cobb angle correction (CR) were then calculated to assess the vertebral height reconstruction. Preoperative and postoperative Oswestry Disability Index (ODI) and visual analogue scale (VAS) were adopted by interviewing patients to assess the mobility improvement and pain relief. Demographic data, body mass index (BMI), lumbar bone mineral density (evaluated by BMD T-score) of each patient, bone cement volume (BV), and bone cement extravasation (BE) were also recorded. Between- and within-group comparisons and multivariable correlation analysis were carried out to analyze the data. VAS and ODI scores were both significantly improved in all of the enrolled cases with no significant differences between groups. Among the three groups, the average age, AVHRR, and BV were significantly different. Occurrence of BE was significantly different between two of the three groups. AVHRR was demonstrated to correlate negatively with preoperative anterior vertebral height ratio and positively with preoperative Cobb angle, CR, diffusion score, and ODI changes. Bone cement distribution is a potential predictor to the reconstructive effects in unilateral PKP for OVCFs. Bone cement distribution is associated with AVHRR and BV, as well as the risk of BE occurrence. Greater bone cement distribution may indicate better vertebral restoration along with a higher BE risk.

  18. Convective cloud vertical velocity and mass-flux characteristics from radar wind profiler observations during GoAmazon2014/5: VERTICAL VELOCITY GOAMAZON2014/5

    DOE PAGES

    Giangrande, Scott E.; Toto, Tami; Jensen, Michael P.; ...

    2016-11-15

    A radar wind profiler data set collected during the 2 year Department of Energy Atmospheric Radiation Measurement Observations and Modeling of the Green Ocean Amazon (GoAmazon2014/5) campaign is used to estimate convective cloud vertical velocity, area fraction, and mass flux profiles. Vertical velocity observations are presented using cumulative frequency histograms and weighted mean profiles to provide insights in a manner suitable for global climate model scale comparisons (spatial domains from 20 km to 60 km). Convective profile sensitivity to changes in environmental conditions and seasonal regime controls is also considered. Aggregate and ensemble average vertical velocity, convective area fraction, andmore » mass flux profiles, as well as magnitudes and relative profile behaviors, are found consistent with previous studies. Updrafts and downdrafts increase in magnitude with height to midlevels (6 to 10 km), with updraft area also increasing with height. Updraft mass flux profiles similarly increase with height, showing a peak in magnitude near 8 km. Downdrafts are observed to be most frequent below the freezing level, with downdraft area monotonically decreasing with height. Updraft and downdraft profile behaviors are further stratified according to environmental controls. These results indicate stronger vertical velocity profile behaviors under higher convective available potential energy and lower low-level moisture conditions. Sharp contrasts in convective area fraction and mass flux profiles are most pronounced when retrievals are segregated according to Amazonian wet and dry season conditions. During this deployment, wet season regimes favored higher domain mass flux profiles, attributed to more frequent convection that offsets weaker average convective cell vertical velocities.« less

  19. The influence of pelvic adjustment on vertical jump height in female university students with functional leg length inequality.

    PubMed

    Gong, Wontae

    2015-01-01

    [Purpose] This study aimed to investigate the effect of pelvic adjustment on vertical jump height (VJH) in female university students with functional leg length inequality (FLLI). [Subjects] Thirty female university students with FLLI were divided into a pelvic adjustment group (n = 15) and a stretching (control) group (n = 15). [Methods] VJH was measured using an OptoGait. [Results] After the intervention, jump height improved significantly compared with the pre-intervention height only in the pelvic adjustment group, while FLLI showed statistically significant improvement in both groups. [Conclusion] Pelvic adjustment as per the Gonstead method can be applied as a method of reducing FLLI and increasing VJH.

  20. Low cortical bone density measured by computed tomography in children and adolescents with untreated hyperthyroidism.

    PubMed

    Numbenjapon, Nawaporn; Costin, Gertrude; Gilsanz, Vicente; Pitukcheewanont, Pisit

    2007-05-01

    To determine whether increased thyroid hormones levels have an effect on various bone components (cortical vs cancellous bone). The anthropometric and 3-dimensional quantitative computed tomography (CT) bone measurements, including bone density (BD), cross-sectional area (CSA) of the lumbar spine and femur, and cortical bone area (CBA) of the femur, of 18 children and adolescents with untreated hyperthyroidism were reviewed and compared with those of age-, sex-, and ethnicity-matched historical controls. No significant differences in height, weight, body mass index (BMI), or pubertal staging between patients and controls were found. Cortical BD was significantly lower (P < .001) in children and adolescents with hyperthyroidism compared with historical controls. After adjusting for weight and height, no difference in femur CSA between hyperthyroid children and historical controls was evident. No significant correlations among thyroid hormone levels, antithyroid antibody levels, and cortical BD values were found. As determined by CT, cortical bone is the preferential site of bone loss in children and adolescents with untreated hyperthyroidism.

  1. 3D finite element analysis of changes in stress levels and distributions for an osseointegrated implant after vertical bone loss.

    PubMed

    Yoon, Kyung-Ho; Kim, Su-Gwan; Lee, Jeong-Hoon; Suh, Seung-Woo

    2011-10-01

    The effect of stress levels and distributions around the internal nonsubmerged type implants after vertical bone resorption was investigated in this study. An HSII implant was placed in 4 cylindrical alveolar bone models with differing degrees of thread exposures. The load applied to each implant was von Mises stress and principal stress, 250 N in axial direction and 30 degrees lateral pressure. The difference in the load between the bone and the connective portion of the implant was obtained using ANSYS analysis. Bone loss in the cervical area of the implant was more obvious under lateral pressure. When more threads were exposed, bone level decreased and the maximum load applied on the fixture increased. It was concluded that higher bone level has a biomechanical advantage with respect to stress concentration.

  2. Adiposity and TV viewing are related to less bone accrual in young children

    PubMed Central

    Wosje, Karen S.; Khoury, Philip R.; Claytor, Randal P.; Copeland, Kristen A.; Kalkwarf, Heidi J.; Daniels, Stephen R.

    2008-01-01

    Objective To examine the relation between baseline fat mass and gain in bone area and bone mass in preschoolers studied prospectively for 4 y, with a focus on the role of physical activity and TV viewing. Study design Children were part of a longitudinal study in which measures of fat, lean and bone mass, height, weight, activity, and diet were taken every 4 months from ages 3 to 7 y. Activity was measured by accelerometer, and TV viewing by parent checklist. We included 214 children with total body dual energy x-ray absorptiometry (Hologic 4500A) scans at ages 3.5 and 7 y. Results Higher baseline fat mass was associated with smaller increases in bone area and bone mass over the next 3.5 y (p<0.001). More TV viewing was related to smaller gains in bone area and bone mass accounting for race, sex, and height. Activity by accelerometer was not associated with bone gains. Conclusions Adiposity and TV viewing are related to less bone accrual in preschoolers. PMID:18692201

  3. Secondary trauma from occlusion: three-dimensional analysis using the finite element method.

    PubMed

    Geramy, Allahyar; Faghihi, Sharieh

    2004-01-01

    Clinical effects of forces applied by dental occlusion on the periodontium have been evaluated for decades. Historically, trauma from occlusion has been considered as a major etiologic factor of inflammatory periodontal diseases, while some researchers have interpreted it to be of less importance or without any detectable importance in periodontics. In this study, five three-dimensional models of a maxillary central incisor were created using ANSYS 5.40. The only difference in each model was the height of the alveolar bone that showed from normal height (13 mm of alveolar bone height) to 8 mm of alveolar bone loss (5 mm of alveolar bone height). Five-point forces of 0.3 N summing up to 1.5 N were applied in a parallel line, 1 mm apical to the incisal edge on the palatal side in a palatolabial direction. The maximum (S1) and minimum (S3) principal stresses in the nodes of the labial side of the periodontal ligament (apical to the alveolar crest) were assessed. Analysis was done using the finite element method. An increase of S1 (up to 16 times in the cervical and 11.25 times in the apical area) and S3 (up to 17.13 times in the cervical and 9.9 times in the apical area) in comparison to the normal model was shown. The highest stress levels were traced in the subcervical area, except for the last model (8 mm of the alveolar bone loss). According to the results of this study, 2.5 mm of alveolar bone loss can be considered as a limit beyond which stress alterations were accelerated. Based on the FEM analysis, alveolar bone loss increases stress (S1 and S3) produced in the PDL, in spite of applying the same force vector.

  4. Markers of Bone Metabolism Are Affected by Renal Function and Growth Hormone Therapy in Children with Chronic Kidney Disease

    PubMed Central

    Doyon, Anke; Fischer, Dagmar-Christiane; Bayazit, Aysun Karabay; Canpolat, Nur; Duzova, Ali; Sözeri, Betül; Bacchetta, Justine; Balat, Ayse; Büscher, Anja; Candan, Cengiz; Cakar, Nilgun; Donmez, Osman; Dusek, Jiri; Heckel, Martina; Klaus, Günter; Mir, Sevgi; Özcelik, Gül; Sever, Lale; Shroff, Rukshana; Vidal, Enrico; Wühl, Elke; Gondan, Matthias; Melk, Anette; Querfeld, Uwe; Haffner, Dieter; Schaefer, Franz

    2015-01-01

    Objectives The extent and relevance of altered bone metabolism for statural growth in children with chronic kidney disease is controversial. We analyzed the impact of renal dysfunction and recombinant growth hormone therapy on a panel of serum markers of bone metabolism in a large pediatric chronic kidney disease cohort. Methods Bone alkaline phosphatase (BAP), tartrate-resistant acid phosphatase 5b (TRAP5b), sclerostin and C-terminal FGF-23 (cFGF23) normalized for age and sex were analyzed in 556 children aged 6–18 years with an estimated glomerular filtration rate (eGFR) of 10–60 ml/min/1.73m2. 41 children receiving recombinant growth hormone therapy were compared to an untreated matched control group. Results Standardized levels of BAP, TRAP5b and cFGF-23 were increased whereas sclerostin was reduced. BAP was correlated positively and cFGF-23 inversely with eGFR. Intact serum parathormone was an independent positive predictor of BAP and TRAP5b and negatively associated with sclerostin. BAP and TRAP5B were negatively affected by increased C-reactive protein levels. In children receiving recombinant growth hormone, BAP was higher and TRAP5b lower than in untreated controls. Sclerostin levels were in the normal range and higher than in untreated controls. Serum sclerostin and cFGF-23 independently predicted height standard deviation score, and BAP and TRAP5b the prospective change in height standard deviation score. Conclusion Markers of bone metabolism indicate a high-bone turnover state in children with chronic kidney disease. Growth hormone induces an osteoanabolic pattern and normalizes osteocyte activity. The osteocyte markers cFGF23 and sclerostin are associated with standardized height, and the markers of bone turnover predict height velocity. PMID:25659076

  5. 47 CFR 90.542 - Broadband transmitting power limits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... combination of antenna height and vertical gain pattern must not exceed 3000 microwatts per square meter on... and an antenna height of 305 m HAAT, except that antenna heights greater than 305 m HAAT are permitted... ERP of 2000 watts and an antenna height of 305 m HAAT, except that antenna heights greater than 305 m...

  6. 47 CFR 90.542 - Broadband transmitting power limits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... combination of antenna height and vertical gain pattern must not exceed 3000 microwatts per square meter on... and an antenna height of 305 m HAAT, except that antenna heights greater than 305 m HAAT are permitted... ERP of 2000 watts and an antenna height of 305 m HAAT, except that antenna heights greater than 305 m...

  7. 47 CFR 80.763 - Effective antenna height.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Effective antenna height. 80.763 Section 80.763... MARITIME SERVICES Standards for Computing Public Coast Station VHF Coverage § 80.763 Effective antenna height. The effective height of the antenna is the vertical distance between the center of the radiating...

  8. 47 CFR 80.763 - Effective antenna height.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Effective antenna height. 80.763 Section 80.763... MARITIME SERVICES Standards for Computing Public Coast Station VHF Coverage § 80.763 Effective antenna height. The effective height of the antenna is the vertical distance between the center of the radiating...

  9. 47 CFR 80.763 - Effective antenna height.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Effective antenna height. 80.763 Section 80.763... MARITIME SERVICES Standards for Computing Public Coast Station VHF Coverage § 80.763 Effective antenna height. The effective height of the antenna is the vertical distance between the center of the radiating...

  10. 47 CFR 80.763 - Effective antenna height.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Effective antenna height. 80.763 Section 80.763... MARITIME SERVICES Standards for Computing Public Coast Station VHF Coverage § 80.763 Effective antenna height. The effective height of the antenna is the vertical distance between the center of the radiating...

  11. 47 CFR 80.763 - Effective antenna height.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Effective antenna height. 80.763 Section 80.763... MARITIME SERVICES Standards for Computing Public Coast Station VHF Coverage § 80.763 Effective antenna height. The effective height of the antenna is the vertical distance between the center of the radiating...

  12. 36 CFR 910.61 - Height of development.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... DEVELOPMENT AREA Glossary of Terms § 910.61 Height of development. Height of development means the vertical... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Height of development. 910.61 Section 910.61 Parks, Forests, and Public Property PENNSYLVANIA AVENUE DEVELOPMENT CORPORATION GENERAL...

  13. 36 CFR 910.61 - Height of development.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... DEVELOPMENT AREA Glossary of Terms § 910.61 Height of development. Height of development means the vertical... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Height of development. 910.61 Section 910.61 Parks, Forests, and Public Property PENNSYLVANIA AVENUE DEVELOPMENT CORPORATION GENERAL...

  14. Efficacy of cancellous block allograft augmentation prior to implant placement in the posterior atrophic mandible.

    PubMed

    Nissan, Joseph; Ghelfan, Oded; Mardinger, Ofer; Calderon, Shlomo; Chaushu, Gavriel

    2011-12-01

    The present study evaluated the outcome of ridge augmentation with cancellous freeze-dried block bone allografts in the posterior atrophic mandible followed by placement of dental implants. A bony deficiency of at least 3 mm, horizontally, vertically, or both, according to computerized tomography (CT) para-axial reconstruction served as inclusion criteria. Implants were inserted after a healing period of 6 months. Bone measurements were taken prior to bone augmentation, during implant placement, and at second-stage surgery. Marginal bone loss and crown-to-implant ratio were also measured. Twenty-nine cancellous allogeneic bone blocks were placed in 21 patients. The mean follow-up was 37 months. Bone block survival rate was 79.3%. Mean horizontal and vertical bone gains were 5.6 and 4.3 mm, respectively. Mean buccal bone resorption was 0.5 mm at implant placement and 0.2 mm at second-stage surgery. A total of 85 implants were placed. Mean bone thickness buccal to the implant neck was 2.5 mm at implant placement and 2.3 mm at second-stage surgery. There was no evidence of vertical bone loss between implant placement and second-stage surgery. Implant survival rate was 95.3%. All patients received a fixed implant-supported prosthesis. At the last follow-up, the mean marginal bone loss was 0.5 mm. The mean crown-to-implant ratio was 0.96. Implant placement in the posterior atrophic mandible following augmentation with cancellous freeze-dried bone block allografts may be regarded as a viable treatment alternative. © 2009 Wiley Periodicals, Inc.

  15. Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study.

    PubMed

    Hedayati, Zohreh; Shomali, Mehrdad

    2016-12-01

    Nowadays, mini screws are used in orthodontic tooth movement to obtain maximum or absolute anchorage. They have gained popularity among orthodontists for en masse retraction of anterior teeth after first premolar extraction in maximum anchorage cases. The purpose of this study was to determine the type of anterior tooth movement during the time when force was applied from different mini screw placements to the anterior power arm with various heights. A finite element method was used for modeling maxillary teeth and bone structure. Brackets, wire, and hooks were also designed for modeling. Two appropriate positions for mini screw in the mesial and distal of the second premolar were designed as fixed nodes. Forces were applied from the mini screw to four different levels of anterior hook height: 0, 3, 6, and 9 mm. Initial tooth movement in eight different conditions was analyzed and calculated with ANSYS software. Rotation of anterior dentition was decreased with a longer anterior power arm and the mesial placement of the mini screw. Bodily movements occurred with the 9-mm height of the power arm in both mini screw positions. Intrusion or extrusion of the anterior teeth segment depended on the level of the mini screw and the edge of the power arm on the Z axis. According to the findings of this study, the best control in the sagittal plane during anterior en masse retraction was achieved by mesial placement of the mini screw and the 9-mm height of the anterior power arm. Where control in the vertical plane was concerned, distal placement of the mini screw with the 6-mm power arm height had minimum adverse effect on anterior dentition.

  16. Vertical distribution of hydrocarbons in the low troposphere below and above the mixing height: tethered balloon measurements in Milan, Italy.

    PubMed

    Sangiorgi, G; Ferrero, L; Perrone, M G; Bolzacchini, E; Duane, M; Larsen, B R

    2011-12-01

    A novel approach for measuring vertical profiles of HCs and particle number concentrations was described and applied in the low troposphere over Milan (Italy) during typical spring and summer days. Particle profiles yielded nearly homogeneous concentrations below the mixing height, with level-to-ground concentration ratios of 92-97%, while HCs showed a more pronounced decrease (74-95%). Vertical mixing and photochemical loss of HCs were demonstrated to cause these gradients. Much lower concentrations were observed for the profiles above the mixing height, where the HC mixtures showed also a different composition, which was partially explained by the horizontal advection of air with HC sources different to those prevailing at the site. The application of pseudo-first order kinetics for reactions between HCs and the hydroxyl radical allowed for the estimation of the vertical mixing time scale in the order of 100 ± 20 min. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Vertical normal modes of a mesoscale model using a scaled height coordinate

    NASA Technical Reports Server (NTRS)

    Lipton, A. E.; Pielke, R. A.

    1986-01-01

    Vertical modes were derived for a version of the Colorado State Regional Atmospheric Mesoscale Modeling System. The impacts of three options for dealing with the upper boundary of the model were studied. The standard model formulation holds pressure constant at a fixed altitude near the model top, and produces a fastest mode with a speed of about 90 m/sec. An alternative formulation, which allows for an external mode, could require recomputation of vertical modes for every surface elevation on the horizontal grid unless the modes are derived in a particular way. These results have bearing on the feasibility of applying vertical mode initialization to models with scaled height coordinates.

  18. The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study.

    PubMed

    Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue

    2018-05-01

    Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Look up: Human adults use vertical height cues in reorientation.

    PubMed

    Du, Yu; Spetch, Marcia L; Mou, Weimin

    2016-11-01

    Numerous studies have shown that people and other animals readily use horizontal geometry (distance and directional information) to reorient, and these cues sometimes dominate over other cues when reorienting in navigable environments. Our study investigated whether horizontal cues (distance/angle) dominate over vertical cues (wall height) when they are in conflict. Adult participants learned two locations (opposite corners) in either a rectangular room (with distance information) or a rhombus room (with angle information). Both training rooms had 2 opposite high walls as height cues. On each trial, participants were disoriented and then asked to locate the correct corners. In testing, the rooms were modified to provide (a) distance or angle cues only, (b) height cues only, and (c) both height and horizontal cues in conflict. Participants located the correct corners successfully with horizontal (distance/angle) or height cues alone. On conflict tests, participants did not show preference for the horizontal information (distance/angle) over the height cues. The results are discussed in terms of the geometric module theory and the adaptive combination theory.

  20. Remeasuring tree heights on permanent plots using rectangular coordinates and one angle per tree

    Treesearch

    Robert L. Neal

    1973-01-01

    Heights of permanent sample trees with tops visible from any point can be measured from that point with any clinometer, measuring one vertical angle per tree. Two horizontal angles and one additional vertical angle per observation point are necessary to orient the point to the plot. Permanently recorded coordinates and elevations of tree locations are used with the...

  1. 21 CFR 130.12 - General methods for water capacity and fill of containers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... height of the double seam. (2) Measure the vertical distance from the top level of the container to the... or altering the height of the double seam. (2) Wash, dry, and weigh the empty container. (3) Fill the container with distilled water at 68 °F to 3/16 inch vertical distance below the top level of the container...

  2. 21 CFR 130.12 - General methods for water capacity and fill of containers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... height of the double seam. (2) Measure the vertical distance from the top level of the container to the... or altering the height of the double seam. (2) Wash, dry, and weigh the empty container. (3) Fill the container with distilled water at 68 °F to 3/16 inch vertical distance below the top level of the container...

  3. 21 CFR 130.12 - General methods for water capacity and fill of containers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... height of the double seam. (2) Measure the vertical distance from the top level of the container to the... or altering the height of the double seam. (2) Wash, dry, and weigh the empty container. (3) Fill the container with distilled water at 68 °F to 3/16 inch vertical distance below the top level of the container...

  4. Predicting vertical jump height from bar velocity.

    PubMed

    García-Ramos, Amador; Štirn, Igor; Padial, Paulino; Argüelles-Cienfuegos, Javier; De la Fuente, Blanca; Strojnik, Vojko; Feriche, Belén

    2015-06-01

    The objective of the study was to assess the use of maximum (Vmax) and final propulsive phase (FPV) bar velocity to predict jump height in the weighted jump squat. FPV was defined as the velocity reached just before bar acceleration was lower than gravity (-9.81 m·s(-2)). Vertical jump height was calculated from the take-off velocity (Vtake-off) provided by a force platform. Thirty swimmers belonging to the National Slovenian swimming team performed a jump squat incremental loading test, lifting 25%, 50%, 75% and 100% of body weight in a Smith machine. Jump performance was simultaneously monitored using an AMTI portable force platform and a linear velocity transducer attached to the barbell. Simple linear regression was used to estimate jump height from the Vmax and FPV recorded by the linear velocity transducer. Vmax (y = 16.577x - 16.384) was able to explain 93% of jump height variance with a standard error of the estimate of 1.47 cm. FPV (y = 12.828x - 6.504) was able to explain 91% of jump height variance with a standard error of the estimate of 1.66 cm. Despite that both variables resulted to be good predictors, heteroscedasticity in the differences between FPV and Vtake-off was observed (r(2) = 0.307), while the differences between Vmax and Vtake-off were homogenously distributed (r(2) = 0.071). These results suggest that Vmax is a valid tool for estimating vertical jump height in a loaded jump squat test performed in a Smith machine. Key pointsVertical jump height in the loaded jump squat can be estimated with acceptable precision from the maximum bar velocity recorded by a linear velocity transducer.The relationship between the point at which bar acceleration is less than -9.81 m·s(-2) and the real take-off is affected by the velocity of movement.Mean propulsive velocity recorded by a linear velocity transducer does not appear to be optimal to monitor ballistic exercise performance.

  5. Predicting Vertical Jump Height from Bar Velocity

    PubMed Central

    García-Ramos, Amador; Štirn, Igor; Padial, Paulino; Argüelles-Cienfuegos, Javier; De la Fuente, Blanca; Strojnik, Vojko; Feriche, Belén

    2015-01-01

    The objective of the study was to assess the use of maximum (Vmax) and final propulsive phase (FPV) bar velocity to predict jump height in the weighted jump squat. FPV was defined as the velocity reached just before bar acceleration was lower than gravity (-9.81 m·s-2). Vertical jump height was calculated from the take-off velocity (Vtake-off) provided by a force platform. Thirty swimmers belonging to the National Slovenian swimming team performed a jump squat incremental loading test, lifting 25%, 50%, 75% and 100% of body weight in a Smith machine. Jump performance was simultaneously monitored using an AMTI portable force platform and a linear velocity transducer attached to the barbell. Simple linear regression was used to estimate jump height from the Vmax and FPV recorded by the linear velocity transducer. Vmax (y = 16.577x - 16.384) was able to explain 93% of jump height variance with a standard error of the estimate of 1.47 cm. FPV (y = 12.828x - 6.504) was able to explain 91% of jump height variance with a standard error of the estimate of 1.66 cm. Despite that both variables resulted to be good predictors, heteroscedasticity in the differences between FPV and Vtake-off was observed (r2 = 0.307), while the differences between Vmax and Vtake-off were homogenously distributed (r2 = 0.071). These results suggest that Vmax is a valid tool for estimating vertical jump height in a loaded jump squat test performed in a Smith machine. Key points Vertical jump height in the loaded jump squat can be estimated with acceptable precision from the maximum bar velocity recorded by a linear velocity transducer. The relationship between the point at which bar acceleration is less than -9.81 m·s-2 and the real take-off is affected by the velocity of movement. Mean propulsive velocity recorded by a linear velocity transducer does not appear to be optimal to monitor ballistic exercise performance. PMID:25983572

  6. Influence of Knee-to-Feet Jump Training on Vertical Jump and Hang Clean Performance.

    PubMed

    Stark, Laura; Pickett, Karla; Bird, Michael; King, Adam C

    2016-11-01

    Stark, L, Pickett, K, Bird, M, and King, AC. Influence of knee-to-feet jump training on vertical jump and hang clean performance. J Strength Cond Res 30(11): 3084-3089, 2016-From a motor learning perspective, the practice/training environment can result in positive, negative, or neutral transfer to the testing conditions. The purpose of this study was to examine the training effect of a novel movement (knee-to-feet [K2F] jumps) and whether a 6-week training program induced a positive transfer effect to other power-related movements (vertical jump and hang clean [HC]). Twenty-six intercollegiate athletes from power-emphasized sports were paired and counter-balanced into a control (i.e., maintained their respective sport-specific lifting regimen) or an experimental group (i.e., completed a 6-week progressive training program of K2F jumps in addition to respective lifting regimen). A pre- and posttest design was used to investigate the effect of training on K2F jump height and transfer effect to vertical jump height (VJH) and 2-repetition maximum (RM) HC performance. A significant increase in K2F jump height was found for the experimental group. Vertical jump height significantly increased from pre- to posttest but no group or interaction (group × time) effect was found, and there were nonsignificant differences for HC. Posttest data showed significant correlations between all pairs of the selected exercises with the highest correlation between K2F jump height and VJ H (R = 0.40) followed by VJH and 2RM HC (R = 0.38) and 2RM HC and K2F jump height (R = 0.23). The results suggest that K2F jump training induced the desired learning effect but was specific to the movement in that no effect of transfer occurred to the other power-related movements. This finding is value for strength and condition professionals who design training programs to enhance athletic performance.

  7. 46 CFR 42.20-70 - Minimum bow height.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Freeboards § 42.20-70 Minimum bow height. (a) The bow height defined as the vertical distance at the forward... 46 Shipping 2 2012-10-01 2012-10-01 false Minimum bow height. 42.20-70 Section 42.20-70 Shipping... less than 0.68. (b) Where the bow height required in paragraph (a) of this section is obtained by sheer...

  8. 46 CFR 42.20-70 - Minimum bow height.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Freeboards § 42.20-70 Minimum bow height. (a) The bow height defined as the vertical distance at the forward... 46 Shipping 2 2011-10-01 2011-10-01 false Minimum bow height. 42.20-70 Section 42.20-70 Shipping... less than 0.68. (b) Where the bow height required in paragraph (a) of this section is obtained by sheer...

  9. 46 CFR 42.20-70 - Minimum bow height.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Freeboards § 42.20-70 Minimum bow height. (a) The bow height defined as the vertical distance at the forward... 46 Shipping 2 2014-10-01 2014-10-01 false Minimum bow height. 42.20-70 Section 42.20-70 Shipping... less than 0.68. (b) Where the bow height required in paragraph (a) of this section is obtained by sheer...

  10. 46 CFR 42.20-70 - Minimum bow height.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Freeboards § 42.20-70 Minimum bow height. (a) The bow height defined as the vertical distance at the forward... 46 Shipping 2 2013-10-01 2013-10-01 false Minimum bow height. 42.20-70 Section 42.20-70 Shipping... less than 0.68. (b) Where the bow height required in paragraph (a) of this section is obtained by sheer...

  11. 46 CFR 42.20-70 - Minimum bow height.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Freeboards § 42.20-70 Minimum bow height. (a) The bow height defined as the vertical distance at the forward... 46 Shipping 2 2010-10-01 2010-10-01 false Minimum bow height. 42.20-70 Section 42.20-70 Shipping... less than 0.68. (b) Where the bow height required in paragraph (a) of this section is obtained by sheer...

  12. The variance needed to accurately describe jump height from vertical ground reaction force data.

    PubMed

    Richter, Chris; McGuinness, Kevin; O'Connor, Noel E; Moran, Kieran

    2014-12-01

    In functional principal component analysis (fPCA) a threshold is chosen to define the number of retained principal components, which corresponds to the amount of preserved information. A variety of thresholds have been used in previous studies and the chosen threshold is often not evaluated. The aim of this study is to identify the optimal threshold that preserves the information needed to describe a jump height accurately utilizing vertical ground reaction force (vGRF) curves. To find an optimal threshold, a neural network was used to predict jump height from vGRF curve measures generated using different fPCA thresholds. The findings indicate that a threshold from 99% to 99.9% (6-11 principal components) is optimal for describing jump height, as these thresholds generated significantly lower jump height prediction errors than other thresholds.

  13. Combination growth hormone and gonadotropin releasing hormone analog therapy in 11beta-hydroxylase deficiency.

    PubMed

    Bajpai, Anurag; Kabra, Madhulika; Menon, P S N

    2006-06-01

    Diagnosis of 11beta-hydroxylase deficiency was made in a boy at the age of 2 1/2 years on the basis of peripheral precocious puberty, growth acceleration (height standard deviation score +4.4) with advanced skeletal maturation (bone age 8.4 years) and elevated deoxycortisol levels. Glucocorticoid supplementation led to normalization of blood pressure but was associated with progression to central precocious puberty and increase in bone age resulting in decrease in predicted adult height to 133.7 cm (target height 163 cm). The child was started on GnRH analog (triptorelin 3.75 mg every 28 days), which led to improvement in predicted adult height by 3.1 cm over 15 months. Addition of growth hormone (0.1 IU/kg/day) resulted in improvement in predicted adult height (151 cm) and height deficit (12 cm) over the next 3.6 years. Final height (151 cm) exceeded predicted height at the initiation of GnRH analog treatment by 17.3 cm. This report suggests that combination GH and GnRH analog treatment may be useful in improving height outcome in children with 11beta-hydroxylase deficiency and compromised final height.

  14. Effect of occlusal vertical dimension on lip positions at smile.

    PubMed

    Chou, Jang-Ching; Thompson, Geoffrey A; Aggarwal, Harshit A; Bosio, Jose A; Irelan, Jon P

    2014-09-01

    In complete mouth reconstructive dentistry, the occlusal vertical dimension may be increased to provide adequate restorative space or to improve esthetics. The effect of increasing the occlusal vertical dimension on the smile is not well understood. The purpose of this study was to evaluate the effect of increasing the occlusal vertical dimension on the dimensions of the smile. Thirty dental students, 12 men and 18 women between the ages of 21 and 30 years old, participated in this study. Polyvinyl siloxane occlusal registrations 2, 4, 6, and 8 mm in thickness were fabricated from articulated stone casts. Posed smile images at occlusal vertical dimension +0, +2, +4, +6, and +8 mm were made with a digital single lens reflex camera mounted on a tripod. A wall-mounted head-positioning device, modified from a cephalometric unit, was used to stabilize the head position. Interlabial gap height, intercommissural width, incisal edge to upper lip, and incisal edge-to-lower lip measurements were made with computer software. The smile index was obtained by dividing width by height. The display zone area was measured by using computer software tracing. One-way repeated measures ANOVA (α=.05) was used for statistical analysis. With an increase in the occlusal vertical dimension, the interlabial gap height, incisal edge to lower lip distance, and display zone area increased significantly (P<.001), whereas the smile index decreased significantly (P<.001). No significant changes were observed in the intercommissural width and incisal edge to upper lip distance. The interlabial gap height, incisal edge-to-lower lip distance, and display zone area increase with increased occlusal vertical dimension. The smile index decreases with increased occlusal vertical dimension. However, the width of the smile and the length of the upper lip tend to remain unchanged. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. Determination of the best pre-jump height for improvement of two-legged vertical jump.

    PubMed

    Jafari, Mahsa; Zolaktaf, Vahid; Marandi, Sayyed M

    2013-04-01

    Athletic performance in many sports depends on two-legged vertical jump. The objective of this study was to examine the effect of different pre-jump height exercises on two-legged vertical jump and to determine the best pre-jump height(s). Subjects included 35 females and 42 males. By matched randomized sampling, subjects of each sex were assigned into four groups, namely, control, 10-cm hurdle, 20-cm hurdle, and 30-cm hurdle. They participated in the same training program for 6 weeks. Statistical analyses were based on one-way and repeated-measure analysis of variance (ANOVA). Analysis of the data showed that practice over hurdles of 10 cm was better than no hurdle and hurdles of >10 cm. Also, jump attempts over hurdles were efficient for trained athletes, but not for untrained athletes. For both sexes, the rate of spike improvement was much better in the experimental groups than in the control groups; it was independent from the rate of progress in jump, which was relatively less evident. It is likely that rather than increasing jump height, training over hurdle enabled the players to use a higher percent of their jump potentials.

  16. Height is more important than light in determining leaf morphology in a tropical forest.

    PubMed

    Cavaleri, Molly A; Oberbauer, Steven F; Clark, David B; Clark, Deborah A; Ryan, Michael G

    2010-06-01

    Both within and between species, leaf physiological parameters are strongly related to leaf dry mass per area (LMA, g/m2), which has been found to increase from forest floor to canopy top in every forest where it has been measured. Although vertical LMA gradients in forests have historically been attributed to a direct phenotypic response to light, an increasing number of recent studies have provided evidence that water limitation in the upper canopy can constrain foliar morphological adaptations to higher light levels. We measured height, light, and LMA of all species encountered along 45 vertical canopy transects across a Costa Rican tropical rain forest. LMA was correlated with light levels in the lower canopy until approximately 18 m sample height and 22% diffuse transmittance. Height showed a remarkably linear relationship with LMA throughout the entire vertical canopy profile for all species pooled and for each functional group individually (except epiphytes), possibly through the influence of gravity on leaf water potential and turgor pressure. Models of forest function may be greatly simplified by estimating LMA-correlated leaf physiological parameters solely from foliage height profiles, which in turn can be assessed with satellite- and aircraft-based remote sensing.

  17. Ultrahigh vertical resolution radar measurements in the lower stratosphere at Arecibo

    NASA Technical Reports Server (NTRS)

    Ierkic, H. M.; Perillat, P.; Woodman, R. F.

    1990-01-01

    The paper reports on heretofore unprecedented observations of the turbulent layers in the lower stratosphere using the Arecibo 2380-MHz radar. Spectral profiles with about 20 m height and 15 s time resolutions at altitudes in the range 16-19 km are used to parametrize relevant characteristics of the turbulence, namely, vertical widths, distributions, lifetimes, and cutoffs height. These measurements validate previous deconvolved estimates and are free from contaminating factors like shear or beam broadening and partial reflections. Some theoretical predictions are verified, in particular those relating to the height of cutoff and the outer scale of the turbulence.

  18. 46 CFR 45.69 - Correction for bow height.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... consideration by the Commandant. (e) The bow height is defined as the vertical distance at the forward... 46 Shipping 2 2014-10-01 2014-10-01 false Correction for bow height. 45.69 Section 45.69 Shipping... § 45.69 Correction for bow height. (a) The minimum summer freeboard of all manned vessels must be...

  19. 36 CFR 1192.73 - Doorways.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... rest and the platform shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height. Vertical alignment may be accomplished by vehicle... existing stations may have a floor height within plus or minus 11/2 inches of the platform height. At key...

  20. 46 CFR 45.69 - Correction for bow height.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... consideration by the Commandant. (e) The bow height is defined as the vertical distance at the forward... 46 Shipping 2 2012-10-01 2012-10-01 false Correction for bow height. 45.69 Section 45.69 Shipping... § 45.69 Correction for bow height. (a) The minimum summer freeboard of all manned vessels must be...

  1. 36 CFR 1192.73 - Doorways.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... rest and the platform shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height. Vertical alignment may be accomplished by vehicle... existing stations may have a floor height within plus or minus 11/2 inches of the platform height. At key...

  2. 36 CFR § 910.61 - Height of development.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true Height of development. § 910... PENNSYLVANIA AVENUE DEVELOPMENT AREA Glossary of Terms § 910.61 Height of development. Height of development means the vertical distance measured from a specified point at the curb level to the highest point of...

  3. 46 CFR 45.69 - Correction for bow height.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... consideration by the Commandant. (e) The bow height is defined as the vertical distance at the forward... 46 Shipping 2 2013-10-01 2013-10-01 false Correction for bow height. 45.69 Section 45.69 Shipping... § 45.69 Correction for bow height. (a) The minimum summer freeboard of all manned vessels must be...

  4. The Influence of Tractor-Seat Height above the Ground on Lateral Vibrations

    PubMed Central

    Gomez-Gil, Jaime; Gomez-Gil, Francisco Javier; Martin-de-Leon, Rebeca

    2014-01-01

    Farmers experience whole-body vibrations when they drive tractors. Among the various factors that influence the vibrations to which the driver is exposed are terrain roughness, tractor speed, tire type and pressure, rear axle width, and tractor seat height above the ground. In this paper the influence of tractor seat height above the ground on the lateral vibrations to which the tractor driver is exposed is studied by means of a geometrical and an experimental analysis. Both analyses show that: (i) lateral vibrations experienced by a tractor driver increase linearly with tractor-seat height above the ground; (ii) lateral vibrations to which the tractor driver is exposed can equal or exceed vertical vibrations; (iii) in medium-size tractors, a feasible 30 cm reduction in the height of the tractor seat, which represents only 15% of its current height, will reduce the lateral vibrations by around 20%; and (iv) vertical vibrations are scarcely influenced by tractor-seat height above the ground. The results suggest that manufacturers could increase the comfort of tractors by lowering tractor-seat height above the ground, which will reduce lateral vibrations. PMID:25340448

  5. The influence of tractor-seat height above the ground on lateral vibrations.

    PubMed

    Gomez-Gil, Jaime; Gomez-Gil, Francisco Javier; Martin-de-Leon, Rebeca

    2014-10-22

    Farmers experience whole-body vibrations when they drive tractors. Among the various factors that influence the vibrations to which the driver is exposed are terrain roughness, tractor speed, tire type and pressure, rear axle width, and tractor seat height above the ground. In this paper the influence of tractor seat height above the ground on the lateral vibrations to which the tractor driver is exposed is studied by means of a geometrical and an experimental analysis. Both analyses show that: (i) lateral vibrations experienced by a tractor driver increase linearly with tractor-seat height above the ground; (ii) lateral vibrations to which the tractor driver is exposed can equal or exceed vertical vibrations; (iii) in medium-size tractors, a feasible 30 cm reduction in the height of the tractor seat, which represents only 15% of its current height, will reduce the lateral vibrations by around 20%; and (iv) vertical vibrations are scarcely influenced by tractor-seat height above the ground. The results suggest that manufacturers could increase the comfort of tractors by lowering tractor-seat height above the ground, which will reduce lateral vibrations.

  6. Segmenting the Femoral Head and Acetabulum in the Hip Joint Automatically Using a Multi-Step Scheme

    NASA Astrophysics Data System (ADS)

    Wang, Ji; Cheng, Yuanzhi; Fu, Yili; Zhou, Shengjun; Tamura, Shinichi

    We describe a multi-step approach for automatic segmentation of the femoral head and the acetabulum in the hip joint from three dimensional (3D) CT images. Our segmentation method consists of the following steps: 1) construction of the valley-emphasized image by subtracting valleys from the original images; 2) initial segmentation of the bone regions by using conventional techniques including the initial threshold and binary morphological operations from the valley-emphasized image; 3) further segmentation of the bone regions by using the iterative adaptive classification with the initial segmentation result; 4) detection of the rough bone boundaries based on the segmented bone regions; 5) 3D reconstruction of the bone surface using the rough bone boundaries obtained in step 4) by a network of triangles; 6) correction of all vertices of the 3D bone surface based on the normal direction of vertices; 7) adjustment of the bone surface based on the corrected vertices. We evaluated our approach on 35 CT patient data sets. Our experimental results show that our segmentation algorithm is more accurate and robust against noise than other conventional approaches for automatic segmentation of the femoral head and the acetabulum. Average root-mean-square (RMS) distance from manual reference segmentations created by experienced users was approximately 0.68mm (in-plane resolution of the CT data).

  7. Contributions of fat mass and fat distribution to hip bone strength in healthy postmenopausal Chinese women.

    PubMed

    Shao, Hong Da; Li, Guan Wu; Liu, Yong; Qiu, Yu You; Yao, Jian Hua; Tang, Guang Yu

    2015-09-01

    The fat and bone connection is complicated, and the effect of adipose tissue on hip bone strength remains unclear. The aim of this study was to clarify the relative contribution of body fat accumulation and fat distribution to the determination of proximal femur strength in healthy postmenopausal Chinese women. This cross-sectional study enrolled 528 healthy postmenopausal women without medication history or known diseases. Total lean mass (LM), appendicular LM (ALM), percentage of lean mass (PLM), total fat mass (FM), appendicular FM (AFM), percentage of body fat (PBF), android and gynoid fat amount, android-to-gynoid fat ratio (AOI), bone mineral density (BMD), and proximal femur geometry were measured by dual energy X-ray absorptiometry. Hip structure analysis was used to compute some variables as geometric strength-related parameters by analyzing the images of the hip generated from DXA scans. Correlation analyses among anthropometrics, variables of body composition and bone mass, and geometric indices of hip bone strength were performed with stepwise linear regression analyses as well as Pearson's correlation analysis. In univariate analysis, there were significantly inverse correlations between age, years since menopause (YSM), hip BMD, and hip geometric parameters. Bone data were positively related to height, body weight, LM, ALM, FM, AFM, and PBF but negatively related to AOI and amount of android fat (all P < 0.05). AFM and AOI were significantly related to most anthropometric parameters. AFM was positively associated with height, body weight, and BMI. AFM was negatively associated with age and YSM. AOI was negatively associated with height, body weight, and BMI. AOI positively associated with age and YSM. LM, ALM, and FM had a positive relationship with anthropometric parameters (P < 0.05 for all). PLM had a negative relationship with those parameters. The correlation between LM, ALM, FM, PLM, ALM, age, and YSM was not significant. In multivariate linear regression analysis, the hip bone strength was observed to have a consistent and unchanged positive association with AFM and a negative association with AOI, whereas its association with other variables of body composition was not significant after adjusting for age, years since menopause, height, body weight, and BMI. AFM may be a positively protective effect for hip bone strength while AOI, rather than android fat, shows a strong negative association with hip bone strength after making an adjustment for confounders (age, YSM, height, body weight, and BMI) in healthy postmenopausal Chinese women. Rational weight control and AOI reduction during menopause may have vital clinical significance in decreasing postmenopausal osteoporosis.

  8. [Dental implantation and soft tissue augmentation after ridge preservation in a molar site: a case report].

    PubMed

    Zhao, L P; Zhan, Y L; Hu, W J; Wang, H J; Wei, Y P; Zhen, M; Xu, T; Liu, Y S

    2016-12-18

    For ideal implant rehabilitation, an adequate bone volume, optical implant position, and stable and healthy soft tissue are required. The reduction of alveolar bone and changes in its morphology subsequent to tooth extraction will result in insufficient amount of bone and adversely affect the ability to optimally place dental implants in edentulous sites. Preservation of alveolar bone volume through ridge preservation has been demonstrated to reduce the vertical and horizontal contraction of the alveolar bone crest after tooth extraction and reduce the need for additional bone augmentation procedures during implant placement. In this case, a patient presented with a mandible molar of severe periodontal disease, the tooth was removed as atraumatically as possible and the graft material of Bio-Oss was loosely placed in the alveolar socket without condensation and covered with Bio-Gide to reconstruct the defects of the alveolar ridge. Six months later, there were sufficient height and width of the alveolar ridge for the dental implant, avoiding the need of additional bone augmentation and reducing the complexity and unpredictability of the implant surgery. Soft tissue defects, such as gingival and connective tissue, played crucial roles in long-term implant success. Peri-implant plastic surgery facilitated development of healthy peri-implant structure able to withstand occlusal forces and mucogingival stress. Six months after the implant surgery, the keratinized gingiva was absent in the buccal of the implant and the vestibular groove was a little shallow. The free gingival graft technique was used to solve the vestibulum oris groove supersulcus and the absence of keratinized gingiva around the implant. The deepening of vestibular groove and broadening of keratinized gingiva were conducive to the long-term health and stability of the tissue surrounding the implant. Implant installation and prosthetic restoration showed favorable outcome after six months.

  9. Socket preservation using bovine bone mineral and collagen membrane: a randomized controlled clinical trial with histologic analysis.

    PubMed

    Cardaropoli, Daniele; Tamagnone, Lorenzo; Roffredo, Alessandro; Gaveglio, Lorena; Cardaropoli, Giuseppe

    2012-08-01

    After tooth extraction, varying amounts of bone resorption occur because of qualitative and quantitative changes at the edentulous site of the alveolar process. The aims of this randomized controlled clinical trial were (1) to compare the postextraction changes in residual ridge dimensions during spontaneous healing with those during socket preservation, (2) to analyze the histologic and histomorphometric aspects of the grafted sockets, and (3) to compare probing procket depth (PPD) and clinical attachment level (CAL) changes at teeth adjacent to extraction sites. Forty-eight teeth were extracted from 41 patients referred for extraction of 1 or more maxillary or mandibular premolars or molars. The edentulous sites were randomly assigned to the control (EXT, extraction alone) or experimental groups (SP, extraction and socket preservation). In the SP group, the sockets were filled with bovine bone mineral and covered with porcine collagen membrane. At baseline and after 4 months, PPD, gingival recession (REC), and CAL were measured at teeth adjacent to the edentulous sites. The changes in ridge dimensions from baseline to 4 months were assessed on dental casts. At 4 months, bone was harvested from the grafted areas in the SP group and the edentulous areas in the EXT group. PPD, REC, and CAL were comparable between groups. However, from baseline to 4 months, the SP group showed significantly less reduction in ridge width (1.04 ± 1.08 mm vs 4.48 ± 0.65 mm, P < .001) and height (0.46 ± 0.46 mm vs 1.54 ± 0.33 mm, P < .001). Histologically, the grafted sockets exhibited various stages of bone maturation and formation without inflammatory responses. No significant difference in the mineralized and nonmineralized fractions was noted between the groups. Socket preservation using bovine bone mineral and porcine collagen membrane considerably limits the amount of horizontal and vertical bone resorption when compared with extraction alone.

  10. Evaluation of the Correlation of Ramus Height, Gonial Angle, and Dental Height with Different Facial Forms in Individuals with Deep Bite Disorders

    PubMed Central

    Ahila, SC; Sasikala, C; Kumar, B Muthu; Tah, Rajdeep; Abinaya, K

    2016-01-01

    Background: Restoring the vertical dimension is a critical procedure in prosthetic dentistry. Anterior facial height has a significant impact on the length of the ramus. Patients with deep bite will exhibit a shorter lower facial height; hence, restoring the vertical dimension esthetically without altering the facial form is highly challenging. Aim: To evaluate the relationship of gonial angle, ramus height, and dental height with different facial forms. Subjects and Methods: A total of 51 subjects in all facial form aged between 20 and 40 with deep bite were randomly selected. Lateral cephalograms and facial photographs were made for each patient. Ramus height was measured on lateral cephalogram by measuring the distance from articulare to gonion. The gonial angles were calculated and anterior and posterior dental height were measured from cephalogram. Facial forms were evaluated using patient's photographs. Results: The obtained measurements were evaluated, and compared statistically with one way analysis of variance and regression correlation test. Statistical analysis revealed that there was no correlation found between the gonial angle and ramus height. Conclusion: Correlation found between the ramus height and anterior and posterior dental height in patients with deep bite disorders. The ramus height can be calculated using the formulas 46.42 + (0.095 × AD height), 46.046+ (0.123 × PD height). PMID:28480098

  11. Present status of the use of growth hormone in short children with bone diseases (diseases of the skeleton).

    PubMed

    Kanaka-Gantenbein, C

    2001-01-01

    Skeletal dysplasias are genetic disorders of bone and cartilage development, mainly characterized by disproportionate short stature. Achondroplasia is the commonest and best described form of skeletal dysplasia, leading to a mean final height of 131+/-5.6 cm for males and 124+/-5.9 cm for females. Growth hormone (GH) has been used in different studies in patients with achondroplasia in order to ameliorate their height, and short term results range from rather positive to moderate. However, disproportionate advancement of bone age has been observed that can compromise the positive effect of such treatment. Furthermore, concern exists about the aggravation of body disproportion necessitating a later leg lengthening procedure in order to achieve proportionate adult stature. In hypochondroplasia, GH treatment seems to give better results when administered at puberty. No data on final height yet exist, however, so that more studies with greater numbers of patients need to be performed before a consensus on GH use in achondroplasia and hypochondroplasia can be reached. Other forms of skeletal dysplasias are quite rare, so that no conclusion on GH use in such patients can be drawn. Finally, in osteogenesis imperfecta, GH administration significantly ameliorates bone density but does not clearly seem to affect final height positively.

  12. Constitutional Delay Influences the Auxological Response to Growth Hormone Treatment in Children with Short Stature and Growth Hormone Sufficiency

    PubMed Central

    Gunn, Katherine C.; Cutfield, Wayne S.; Hofman, Paul L.; Jefferies, Craig A.; Albert, Benjamin B.; Gunn, Alistair J.

    2014-01-01

    In a retrospective, population based cohort study, we examined whether constitutional delay was associated with the growth response to growth hormone (GH) in children with short stature and normal GH responses. 70 patients were treated with 21 GH iu/m2/week from 1975 to 2013 throughout New Zealand. Demographic and auxological data were prospectively collected and standard deviation scores (SDS) were calculated for height (HtSDS), yearly growth velocity (GV-SDS), body mass index (BMI-SDS) and predicted adult height (PAH-SDS) at time of the last available bone age. In the first year, GH was associated with marked increase in HtSDS (+0.46 (0.19, 0.76), p < 0.001) and GV-SDS (from −1.9 (−3.6, −0.7) to +2.7 (0.45, 4.2), p < 0.001). The increase in HtSDS but not in GV-SDS was greatest with younger patients and greater bone age delay, with no effect of sex, BMI-SDS or baseline HtSDS. PAH-SDS increased with treatment (+0.94 (0.18, 1.5)); increased PAH-SDS was associated with less bone age delay and greater initial increase in HtSDS. This study shows that greater bone age delay was associated with greater initial improvement in height but less improvement in predicted adult heights, suggesting that children with very delayed bone ages may show accelerated maturation during GH treatment. PMID:25317732

  13. Constitutional delay influences the auxological response to growth hormone treatment in children with short stature and growth hormone sufficiency.

    PubMed

    Gunn, Katherine C; Cutfield, Wayne S; Hofman, Paul L; Jefferies, Craig A; Albert, Benjamin B; Gunn, Alistair J

    2014-08-14

    In a retrospective, population based cohort study, we examined whether constitutional delay was associated with the growth response to growth hormone (GH) in children with short stature and normal GH responses. 70 patients were treated with 21 GH iu/m2/week from 1975 to 2013 throughout New Zealand. Demographic and auxological data were prospectively collected and standard deviation scores (SDS) were calculated for height (HtSDS), yearly growth velocity (GV-SDS), body mass index (BMI-SDS) and predicted adult height (PAH-SDS) at time of the last available bone age. In the first year, GH was associated with marked increase in HtSDS (+0.46 (0.19, 0.76), p < 0.001) and GV-SDS (from -1.9 (-3.6, -0.7) to +2.7 (0.45, 4.2), p < 0.001). The increase in HtSDS but not in GV-SDS was greatest with younger patients and greater bone age delay, with no effect of sex, BMI-SDS or baseline HtSDS. PAH-SDS increased with treatment (+0.94 (0.18, 1.5)); increased PAH-SDS was associated with less bone age delay and greater initial increase in HtSDS. This study shows that greater bone age delay was associated with greater initial improvement in height but less improvement in predicted adult heights, suggesting that children with very delayed bone ages may show accelerated maturation during GH treatment.

  14. Modeling the CAPTEX Vertical Tracer Concentration Profiles.

    NASA Astrophysics Data System (ADS)

    Draxler, Roland R.; Stunder, Barbara J. B.

    1988-05-01

    Perfluorocarbon tracer concentration profiles measured by aircraft 600-900 km downwind of the release locations during CAPTEX are discussed and compared with some model results. In general, the concentrations decreased with height in the upper half of the boundary layer where the aircraft measurements were made. The results of a model sensitivity study suggested that the shape of the profile was primarily due to winds increasing with height and relative position of the sampling with respect to the upwind and downwind edge of the plume. Further modeling studies showed that relatively simple vertical mixing parameterizations could account for the complex vertical plume structure when the model had sufficient vertical resolution. In general, the model performed better with slower winds and corresponding longer transport times.

  15. A Laboratory Study of Vortical Structures in Rotating Convection Plumes

    NASA Astrophysics Data System (ADS)

    Fu, Hao; Sun, Shiwei; Wang, Yuan; Zhou, Bowen; Thermal Turbulence Research Team

    2015-11-01

    A laboratory study of the columnar vortex structure in rotating Rayleigh-Bénard convection is conducted. A rectangular water tank is uniformly heated from below and cooled from above, with Ra = (6 . 35 +/- 0 . 77) ×107 , Ta = 9 . 84 ×107 , Pr = 7 . 34 . The columnar vortices are vertically aligned and quasi steady. Two 2D PIV systems were used to measure velocity field. One system performs horizontal scans at 9 different heights every 13.6s, covering 62% of the total depth. The other system scans vertically to obtain the vertical velocity profile. The measured vertical vorticity profiles of most vortices are quasi-linear with height while the vertical velocities are nearly uniform with only a small curvature. A simple model to deduce vertical velocity profile from vertical vorticity profile is proposed. Under quasi-steady and axisymmetric conditions, a ``vortex core'' assumption is introduced to simplify vertical vorticity equation. A linear ODE about vertical velocity is obtained whenever a vertical vorticity profile is given and solved with experimental data as input. The result is approximately in agreement with the measurement. This work was supported by Undergraduates Training Project (J1103410).

  16. Analysis of vertical distributions and effective flight layers of insects: three-dimensional simulation of flying insects and catch at trap heights

    USDA-ARS?s Scientific Manuscript database

    The mean height and standard deviation (SD) of flight is calculated for over 100 insect species from their catches on trap heights reported in the literature. The iterative equations for calculating mean height and SD are presented. The mean flight height for 95% of the studies varied from 0.17 to 5...

  17. Effects of Isometric Scaling on Vertical Jumping Performance

    PubMed Central

    Bobbert, Maarten F.

    2013-01-01

    Jump height, defined as vertical displacement in the airborne phase, depends on vertical takeoff velocity. For centuries, researchers have speculated on how jump height is affected by body size and many have adhered to what has come to be known as Borelli’s law, which states that jump height does not depend on body size per se. The underlying assumption is that the amount of work produced per kg body mass during the push-off is independent of size. However, if a big body is isometrically downscaled to a small body, the latter requires higher joint angular velocities to achieve a given takeoff velocity and work production will be more impaired by the force-velocity relationship of muscle. In the present study, the effects of pure isometric scaling on vertical jumping performance were investigated using a biologically realistic model of the human musculoskeletal system. The input of the model, muscle stimulation over time, was optimized using jump height as criterion. It was found that when the human model was miniaturized to the size of a mouse lemur, with a mass of about one-thousandth that of a human, jump height dropped from 40 cm to only 6 cm, mainly because of the force-velocity relationship. In reality, mouse lemurs achieve jump heights of about 33 cm. By implication, the unfavourable effects of the small body size of mouse lemurs on jumping performance must be counteracted by favourable effects of morphological and physiological adaptations. The same holds true for other small jumping animals. The simulations for the first time expose and explain the sheer magnitude of the isolated effects of isometric downscaling on jumping performance, to be counteracted by morphological and physiological adaptations. PMID:23936494

  18. SIGNIFICANCE OF PREOPERATIVE EXTERNAL LIMITING MEMBRANE HEIGHT ON VISUAL PROGNOSIS IN PATIENTS UNDERGOING MACULAR HOLE SURGERY.

    PubMed

    Geenen, Caspar; Murphy, Declan C; Sandinha, Maria T; Rees, Jon; Steel, David H W

    2018-03-05

    To investigate the association between the vertical elevation of the external limiting membrane (ELM) and visual outcome in patients undergoing surgery for idiopathic full-thickness macular hole. Retrospective observational study of a consecutive cohort of patients undergoing vitrectomy to treat macular hole. The greatest vertical height of the central ELM above the retinal pigment epithelium (ELM height) was measured on spectral domain optical coherence tomography preoperatively. The relationship of ELM height to other preoperative and postoperative variables, including macular hole width and height, and visual acuity was analyzed. Data from 91 eyes of 91 patients who had undergone successful hole closure were included. The mean ELM height was 220 μm (range 100-394). There were significant correlations between the ELM height and the diameter of the hole, hole height, and worsening preoperative visual acuity. For holes less than 400 μm in width, better postoperative visual acuity was significantly predicted by a lower ELM height. The ELM height varies widely in idiopathic macular hole. It is higher in eyes where the hole is wider and also when the hole itself is higher. For holes of less than 400 μm in width, a lower ELM height is a strong independent predictor of a good postoperative outcome.

  19. Naturally together: pitch-height and brightness as coupled factors for eliciting the SMARC effect in non-musicians.

    PubMed

    Pitteri, Marco; Marchetti, Mauro; Priftis, Konstantinos; Grassi, Massimo

    2017-01-01

    Pitch-height is often labeled spatially (i.e., low or high) as a function of the fundamental frequency of the tone. This correspondence is highlighted by the so-called Spatial-Musical Association of Response Codes (SMARC) effect. However, the literature suggests that the brightness of the tone's timbre might contribute to this spatial association. We investigated the SMARC effect in a group of non-musicians by disentangling the role of pitch-height and the role of tone-brightness. In three experimental conditions, participants were asked to judge whether the tone they were listening to was (or was not) modulated in amplitude (i.e., vibrato). Participants were required to make their response in both the horizontal and the vertical axes. In a first condition, tones varied coherently in pitch (i.e., manipulation of the tone's F0) and brightness (i.e., manipulation of the tone's spectral centroid); in a second condition, pitch-height varied whereas brightness was fixed; in a third condition, pitch-height was fixed whereas brightness varied. We found the SMARC effect only in the first condition and only in the vertical axis. In contrast, we did not observe the effect in any of the remaining conditions. The present results suggest that, in non-musicians, the SMARC effect is not due to the manipulation of the pitch-height alone, but arises because of a coherent change of pitch-height and brightness; this effect emerges along the vertical axis only.

  20. Arthropod vertical stratification in temperate deciduous forests: Implications for conservation oriented management

    Treesearch

    Ulyshen Michael

    2011-01-01

    Studies on the vertical distribution patterns of arthropods in temperate deciduous forests reveal highly stratified (i.e., unevenly vertically distributed) communities. These patterns are determined by multiple factors acting simultaneously, including: (1) time (forest age, season, time of day); (2) forest structure (height, vertical foliage complexity, plant surface...

  1. Crown development in a pioneer tree, Rhus trichocarpa, in relation to the structure and growth of individual branches.

    PubMed

    Osada, Noriyuki

    2006-01-01

    Based on an allometric reconstruction, the structure and biomass-allocation patterns of branches and current-year shoots were investigated in branches of various heights in the pioneer tree Rhus trichocarpa, to evaluate how crown development is achieved and limited in association with height. Path analysis was conducted to explore the effects of light availability, basal height and size of individual branches on branch structure and growth. Branch angle was affected by basal height, whereas branch mass was influenced primarily by light availability. This result suggests that branch structure is strongly constrained by basal height, and that trees mediate such constraints under different light environments. Previous-year leaf area and light availability showed positive effects on current-year stem mass. In contrast, branch basal height and mass negatively affected current-year stem mass. Moreover, the length of stems of a given diameter decreased with increasing branch height. Therefore the cost of biomass investment for a unit growth in length is greater for branches of larger size and at upper positions. Vertical growth rate in length decreased with increasing height. Height-dependent changes in stem allometry and angle influenced the reduction in vertical growth rate to a similar degree.

  2. The effect of gastrostomy tube feeding on body protein and bone mineralization in children with quadriplegic cerebral palsy.

    PubMed

    Arrowsmith, Fiona; Allen, Jane; Gaskin, Kevin; Somerville, Helen; Clarke, Samantha; O'Loughlin, Edward

    2010-11-01

    The aim of this study was to investigate the effect of gastrostomy tube feeding on body protein and bone mineralization in malnourished children with cerebral palsy (CP). Children aged between 4 and 18 years with spastic quadriplegic CP (Gross Motor Function Classification System level V) were recruited from the Children's Hospital at Westmead to participate in this prospective cohort study. The children had measurements of anthropometry (weight, height, and skinfold), bone mineral content (BMC) by dual-energy X-ray absorptiometry, and total body protein (TBP) by neutron activation analysis before and after gastrostomy tube feeding. Comparison data were collected prospectively from age-matched healthy children and extracted from databases for this study. A total of 21 children (nine females, 12 males) participated in the study (median age 8 y 5 mo; interquartile range [IQR] 6 y 9 mo-11 y 10 mo). The median length of time of gastrostomy feeding was 19.4 months (IQR 7.7-29.9 mo). Significant (p<0.05) improvements were found in the median values for weight (15.4-23.3 kg), weight standard deviation scores (SDS; -4.8 to -3.0), height (105.4-118.3 cm), per cent body fat (10.7-16.3), TBP (2.4-3.4 kg), TBP per cent predicted for height (83.4-99.0), and BMC (469-626 g). No significant increases were found in height SDS, TBP per cent predicted for age, or BMC SDS for age or height. Malnourished children with quadriplegic CP showed significant increases in body fat and protein with gastrostomy tube feeding. No significant change in bone mineralization predicted for age or height was observed. © The Authors. Journal compilation © Mac Keith Press 2010.

  3. Significance of maxillary sinus mucosal thickening in patients with periodontal disease.

    PubMed

    Ren, Song; Zhao, Haijiao; Liu, Jingbo; Wang, Qingxuan; Pan, Yaping

    2015-12-01

    To characterise and measure the Schneiderian membranes of individuals with periodontal diseases in China and to analyse the factors impacting maxillary sinus mucosal thickness using cone-beam computed tomography (CBCT). A cohort of 221 patients with periodontal disease was subjected to cross-sectional CBCT examination. Various parameters, including age, sex, alveolar bone loss, furcation lesions and vertical infrabony pockets, were analysed as correlates of mucosal thickening (MT). Sinus mucosal thickness ≥ 2 mm qualified as MT. MT was detected in 103 (48.9%) patients, increasing in frequency as the degree of alveolar bone loss advanced (mild, 14.5%; moderate, 29.5%; severe, 87.9%). The association between MT and vertical infrabony pockets was statistically significant (P < 0.001). The likelihood of MT increased with moderate [odds ratio (OR) = 1.02] and severe (OR = 4.62) periodontal bone loss (P < 0.001), as well as with furcation lesions (OR = 2.76) and vertical infrabony pockets (OR = 13.58). Relative to the case in patients with periodontitis and normal mucosa, the probability of MT increased dramatically as alveolar bone loss worsened. Periodontal pathologies (i.e. furcation lesions and vertical infrabony pockets) were also more likely to coincide with MT. © 2015 FDI World Dental Federation.

  4. The three-dimensional kinematics of a barbell during the snatch of Taiwanese weightlifters.

    PubMed

    Chiu, Hung-Ta; Wang, Chih-Hung; Cheng, Kuangyou B

    2010-06-01

    The purpose of this study is to characterize the trajectory of a barbell and clarify whether there is a standard pattern in the barbell trajectory for each lifter. Two high-speed cameras (mega-speed MS1000, sampling rate=120 Hz) were used to film the barbell trajectories of male Taiwanese weightlifters under competitive conditions. Twenty-four successful lifts were filmed and classified into 3 groups (n=8 per group) by relative barbell-mass (RBM): the better-performance group (RBM>1.63), the middle group (1.28

  5. 36 CFR § 1192.73 - Doorways.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... rest and the platform shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height. Vertical alignment may be accomplished by vehicle... existing stations may have a floor height within plus or minus 11/2 inches of the platform height. At key...

  6. Complications related to bone augmentation procedures of localized defects in the alveolar ridge. A retrospective clinical study.

    PubMed

    Jensen, Anders Torp; Jensen, Simon Storgård; Worsaae, Nils

    2016-06-01

    This retrospective clinical study aims to evaluate complications after augmentation of localized bone defects of the alveolar ridge. From standardized registrations, the following complications related to bone augmentation procedures were recorded: soft tissue dehiscence, infection, sensory disturbance, additional augmentation procedures needed, and early implant failure. A total of 223 patients (132 women, 91 men; mean age 23.5 years; range 17-65 years) with 331 bone defects had bone augmentation performed into which 350 implants were placed. Soft tissue dehiscence occurred in 1.7 % after GBR procedures, 25.9 % after staged horizontal ridge augmentation, and 18.2 % after staged vertical ridge augmentation. Infections were diagnosed in 2 % after GBR procedures, 12.5 % after sinus floor elevation (SFE) (transcrestal technique), 5 % after staged SFE, 11 % after staged horizontal ridge augmentation, and 9 % after staged vertical ridge augmentation. Additional augmentation procedures were needed in 2 % after GBR procedures, 37 % after staged horizontal ridge augmentation, and 9 % after staged vertical ridge augmentation. A total of six early implant failures occurred (1.7 %), four after GBR procedures (1.6 %), and two (12 %) after staged vertical ridge augmentation. Predictable methods exist to augment localized defects in the alveolar ridge, as documented by low complication rates and high early implant survival rates.

  7. Use of Aromatase Inhibitors in Large Cell Calcifying Sertoli Cell Tumors: Effects on Gynecomastia, Growth Velocity, and Bone Age

    PubMed Central

    Crocker, Melissa K.; Gourgari, Evgenia; Stratakis, Constantine A.

    2014-01-01

    Context: Large cell calcifying Sertoli cell tumors (LCCSCT) present in isolation or, especially in children, in association with Carney Complex (CNC) or Peutz-Jeghers Syndrome (PJS). These tumors overexpress aromatase (CYP19A1), which leads to increased conversion of delta-4-androstenedione to estrone and testosterone to estradiol. Prepubertal boys may present with growth acceleration, advanced bone age, and gynecomastia. Objective: To investigate the outcomes of aromatase inhibitor therapy (AIT) in prepubertal boys with LCCSCTs. Design: Case series of a very rare tumor and chart review of cases treated at other institutions. Setting: Tertiary care and referral center. Patients: Six boys, five with PJS and one with CNC, were referred to the National Institutes of Health for treatment of LCCSCT. All patients had gynecomastia, testicular enlargement, and advanced bone ages, and were being treated by their referring physicians with AIT. Interventions: Patients were treated for a total of 6–60 months on AIT. Main Outcome Measures: Height, breast tissue mass, and testicular size were all followed; physical examination, scrotal ultrasounds, and bone ages were obtained, and hormonal concentrations and tumor markers were measured. Results: Tumor markers were negative. All patients had decreases in breast tissue while on therapy. Height percentiles declined, and predicted adult height moved closer to midparental height as bone age advancement slowed. Testicular enlargement stabilized until entry into central puberty. Only one patient required unilateral orchiectomy. Conclusions: Patients with LCCSCT benefit from AIT with reduction and/or elimination of gynecomastia and slowing of linear growth and bone age advancement. Further study of long-term outcomes and safety monitoring are needed but these preliminary data suggest that mammoplasty and/or orchiectomy may be foregone in light of the availability of medical therapy. PMID:25226294

  8. Growth, body composition, and bone density following pediatric liver transplantation.

    PubMed

    Sheikh, Amin; Cundy, Tim; Evans, Helen Maria

    2018-04-24

    Patients transplanted for cholestatic liver disease are often significantly fat-soluble vitamin deficient and malnourished pretransplant, with significant corticosteroid exposure post-transplant, with increasing evidence of obesity and metabolic syndrome post-LT. Our study aimed to assess growth, body composition, and BMD in patients post-pediatric LT. Body composition and bone densitometry scans were performed on 21 patients. Pre- and post-transplant anthropometric data were analyzed. Bone health was assessed using serum ALP, calcium, phosphate, and procollagen-1-N-peptide levels. Median ages at transplant and at this assessment were 2.7 and 10.6 years, respectively. Physiological markers of bone health, median z-scores for total body, and lumbar spine aBMD were normal. Bone area was normal for height and BMAD at L3 was normal for age, indicating, respectively, normal cortical and trabecular bone accrual. Median z-scores for weight, height, and BMI were 0.6, -0.9, 1.8 and 0.6, 0.1, 0.8 pre- and post-transplant, respectively. Total body fat percentages measured on 21 body composition scans revealed 2 underweight, 7 normal, 6 overweight, and 6 obese. Bone mass is preserved following pediatric LT with good catch-up height. About 52% of patients were either overweight/obese post-transplant, potentially placing them at an increased risk of metabolic syndrome and its sequelae in later life. BMI alone is a poor indicator of nutritional status post-transplant. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Determination of physical height from crown dimensions of deciduous tooth: A dental morphometric study.

    PubMed

    Ramanna, C; Kamath, Venkatesh V; Sharada, C; Srikanth, N

    2016-01-01

    Dental morphometrics is a subject of great significance in forensic odontology in identification of an individual. Use of teeth to represent a physical profile is valuable for identification of an individual. The present study aims to assess the clinical crown length (CL) of erupted deciduous teeth and height of the child. A correlation of these parameters was attempted to arrive at a mathematical equation which would formulate a ratio of tooth CL to individual height that would support in estimating the probable height of the child. About 60 children (30 males and 30 females) of age ranged from 3-6 years were included in this study. Clinical vertical CLs of the deciduous dentition (tooth numbers 51, 52, 53, 54, and 55) were calculated using digital Vernier calipers (Aerospace Ltd., Bengaluru, Karnataka, India) on the cast models. Child height was measured using a standard measuring tape. Ratios of deciduous CL to height of the child were recorded. Linear stepwise forward regression analysis was applied to predict the probability of CL of a tooth most likely to support in prediction of physical height of the child. Tabulated results showed a probable correlation between tooth CL and height of the child. Tooth CLs of deciduous upper right second molar (55) among the males, lateral incisor (52) among females, and canine (53) using the combined male and female data were statistically significant, and they approximately predicted the child height with minimal variations. Mathematically derived equations based on linear stepwise forward regression analysis using sixty children data are height prediction (derived from combined data of male and female children) = 400.558 + 90.264 (53 CL), male child height prediction (derived from data of male children) = 660.290 + 72.970 (55 CL), and female child height prediction (derived from data of female children) = -187.942 + 194.818 (52 CL). In conclusion, clinical vertical CL is an important parameter in prediction of individual height and possible identification of the individual. An extension of the similar technique to all the deciduous dentition using a larger group of children would probably give us the best options available among vertical CLs for prediction of the child height.

  10. Randomized Trial of Aromatase Inhibitors, Growth Hormone, or Combination in Pubertal Boys with Idiopathic, Short Stature.

    PubMed

    Mauras, Nelly; Ross, Judith L; Gagliardi, Priscila; Yu, Y Miles; Hossain, Jobayer; Permuy, Joseph; Damaso, Ligeia; Merinbaum, Debbie; Singh, Ravinder J; Gaete, Ximena; Mericq, Veronica

    2016-12-01

    Growth of short children in puberty is limited by the effect of estrogen on epiphyseal fusion. To compare: 1) the efficacy and safety of aromatase inhibitors (AIs) vs GH vs AI/GH on increasing adult height potential in pubertal boys with severe idiopathic short stature (ISS); and 2) differences in body composition among groups. Randomized three-arm open-label comparator. Outpatient clinical research. Seventy-six pubertal boys [mean (SE) age, 14.1 (0.1) years] with ISS [height SD score (SDS), -2.3 (0.0)]. Daily AIs (anastrozole or letrozole), GH, or AI/GH for 24-36 months. Anthropometry, bone ages, dual x-ray absorptiometry, spine x-rays, hormones, safety labs. Height gain [mean (SE)] at 24 months was: AI, +14.0 (0.8) cm; GH, +17.1 (0.9) cm; AI/GH, +18.9 (0.8) cm (P < .0006, analysis of covariance). Height SDS was: AI, -1.73 (0.12); GH, -1.43 (0.14); AI/GH, -1.25 (0.12) (P < .0012). Those treated through 36 months grew more. Regardless of treatment duration, height SDS at near-final height [n = 71; age, 17.4 (0.2) years; bone age, 15.3 (0.1) years; height achieved, ∼97.6%] was: AI, -1.4 (0.1); GH, -1.4 (0.2); AI/GH, -1.0 (0.1) (P = .06). Absolute height change was: AI, +18.2 (1.6) cm; GH, +20.6 (1.5) cm; AI/GH, +22.5 (1.4) cm (P = .01) (expected height gain at -2.0 height SDS, +13.0 cm). AI/GH had higher fat free mass accrual. Measures of bone health, safety labs, and adverse events were similar in all groups. Letrozole caused higher T and lower estradiol than anastrozole. Combination therapy with AI/GH increases height potential in pubertal boys with ISS more than GH and AI alone treated for 24-36 months with a strong safety profile.

  11. Vertical distribution of haematophagous Diptera in temperate forests of the southeastern U.S.A.

    PubMed

    Swanson, D A; Adler, P H

    2010-06-01

    The vertical distribution of blood-feeding flies in two temperate forests in the southeastern U.S.A. was determined by placing 15 Centers for Disease Control and Prevention miniature light traps (12 CO(2)-baited, three unbaited controls), without lights, at three heights (1.5 m, 5.0 m, 10.0 m). More than 6550 haematophagous flies, representing 49 species in four families, were collected. Eighteen species were taken almost exclusively (90-100%) at 1.5 m or 10.0 m, and the mean number of flies per trap differed significantly with height for another six species. Five species exhibited shifts in vertical distribution between the two forests, indicating that forest structure could influence the height of host searching. Most (52.5%) mammalophilic flies were collected at 1.5 m, whereas most (56.4%) ornithophilic flies were taken at 10.0 m, suggesting that host associations influence vertical distributions. The significant differences in the composition of haematophagous fly populations among forest strata emphasize the importance of trap placement in vector surveillance and of understanding the ecological relationships of blood-feeding flies.

  12. Risk factors for low bone mineral density in children and adolescents with inflammatory bowel disease.

    PubMed

    Lopes, Letícia Helena Caldas; Sdepanian, Vera Lucia; Szejnfeld, Vera Lúcia; de Morais, Mauro Batista; Fagundes-Neto, Ulysses

    2008-10-01

    To evaluate bone mineral density of the lumbar spine in children and adolescents with inflammatory bowel disease, and to identify the clinical risk factors associated with low bone mineral density. Bone mineral density of the lumbar spine was evaluated using dual-energy X-ray absorptiometry (DXA) in 40 patients with inflammatory bowel disease. Patients were 11.8 (SD = 4.1) years old and most of them were male (52.5%). Multiple linear regression analysis was performed to identify potential associations between bone mineral density Z-score and age, height-for-age Z-score, BMI Z-score, cumulative corticosteroid dose in milligrams and in milligrams per kilogram, disease duration, number of relapses, and calcium intake according to the dietary reference intake. Low bone mineral density (Z-score bellow -2) was observed in 25% of patients. Patients with Crohn's disease and ulcerative colitis had equivalent prevalence of low bone mineral density. Multiple linear regression models demonstrated that height-for-age Z-score, BMI Z-score, and cumulative corticosteroid dose in mg had independent effects on BMD, respectively, beta = 0.492 (P = 0.000), beta = 0.460 (P = 0.001), beta = - 0.014 (P = 0.000), and these effects remained significant after adjustments for disease duration, respectively, beta = 0.489 (P = 0.013), beta = 0.467 (P = 0.001), and beta = - 0.005 (P = 0.015). The model accounted for 54.6% of the variability of the BMD Z-score (adjusted R2 = 0.546). The prevalence of low bone mineral density in children and adolescents with inflammatory bowel disease is considerably high and independent risk factors associated with bone mineral density are corticosteroid cumulative dose in milligrams, height-for-age Z-score, and BMI Z-score.

  13. Selective excitation of tropical atmospheric waves in wave-CISK: The effect of vertical wind shear

    NASA Technical Reports Server (NTRS)

    Zhang, Minghua; Geller, Marvin A.

    1994-01-01

    The growth of waves and the generation of potential energy in wave-CISK require unstable waves to tilt with height oppositely to their direction of propagation. This makes the structures and instability properties of these waves very sensitive to the presence of vertical shear in the basic flow. Equatorial Kelvin and Rossby-gravity waves have opposite phase tilt with height to what they have in the stratosphere, and their growth is selectively favored by basic flows with westward vertical shear and eastward vertical shear, respectively. Similar calculations are also made for gravity waves and Rossby waves. It is shown that eastward vertical shear of the basic flow promotes CISK for westward propagating Rossby-gravity, Rossby, and gravity waves and suppresses CISK for eastward propagating Kelvin and gravity waves, while westward shear of the basic flow has the reverse effects.

  14. Does head posture have a significant effect on the hyoid bone position and sternocleidomastoid electromyographic activity in young adults?

    PubMed

    Valenzuela, Saúl; Miralles, Rodolfo; Ravera, María José; Zúñiga, Claudia; Santander, Hugo; Ferrer, Marcelo; Nakouzi, Jorge

    2005-07-01

    The aim of this study was to evaluate the associations between head posture (head extension, normal head posture, and head flexion) and anteroposterior head position, hyoid bone position, and the sternocleidomastoid integrated electromyographic (IEMG) activity in a sample of young adults. The study included 50 individuals with natural dentition and bilateral molar support. A lateral craniocervical radiograph was taken for each subject and a cephalometric analysis was performed. Head posture was measured by means of the craniovertebral angle formed by the MacGregor plane and the odontoid plane. According to the value of this angle, the sample was divided into the following three groups: head extension (less than 95 degrees); normal head posture (between 95 degrees and 106 degrees); and head flexion (more than 106 degrees). The following cephalometric measurements were taken to compare the three groups: anteroposterior head position (true vertical plane/pterygoid distance), anteroposterior hyoid bone position (true vertical plane-Ha distance), vertical hyoid bone position (H-H' distance in the hyoid triangle), and CO-C2 distance. In the three groups, IEMG recordings at rest and during swallowing of saliva and maximal voluntary clenching were performed by placing bipolar surface electrodes on the right and left sternocleidomastoid muscles. In addition, the condition with/without craniomandibular dysfunction (CMD) in each group was also assessed. Head posture showed no significant association with anteroposterior head position, anteroposterior hyoid bone position, vertical hyoid bone position, or sternocleidomastoid IEMG activity. There was no association to head posture with/without the condition of CMD. Clinical relevance of the results is discussed.

  15. Osteoporosis

    MedlinePlus

    ... to restore the height of the vertebrae) Spinal fusion (bones of your spine are joined together so ... osteoporosis Patient Instructions Hip fracture - discharge Preventing falls Images Compression fracture Bone density scan Osteoporosis Osteoporosis Hip ...

  16. Estimating insect flight densities from attractive trap catches and flight height distributions

    USDA-ARS?s Scientific Manuscript database

    Insect species often exhibit a specific mean flight height and vertical flight distribution that approximates a normal distribution with a characteristic standard deviation (SD). Many studies in the literature report catches on passive (non-attractive) traps at several heights. These catches were us...

  17. Hard tissue alterations after socket preservation with additional buccal overbuilding: a study in the beagle dog.

    PubMed

    Fickl, Stefan; Zuhr, Otto; Wachtel, Hannes; Kebschull, Moritz; Hürzeler, Markus B

    2009-10-01

    The aim of this study was to histometrically assess alterations of the ridge following socket preservation alone and socket preservation with additional buccal overbuilding. In five beagle dogs four extraction sites were randomly subjected to one of the following treatments: Tx 1: The socket was filled with BioOss Collagen and covered with a free gingival graft from the palate. Tx 2: The buccal bone plate was augmented using the GBR-technique, the socket was filled with BioOss Collagen and covered with a free gingival graft. Tx 3: The buccal bone plate was forced into a buccal direction using a manual bone spreader. The socket was filled with BioOss Collagen and covered with a free gingival graft from the palate. Tx 4: The socket was filled with BioOss Collagen and a combined free gingival/connective tissue graft was used to cover the socket and for buccal tissue augmentation. For each experimental site, two histological sections were subjected to histometric analysis and evaluated for (i) vertical bone dimensions and (ii) horizontal bone dimensions. All treatment groups showed horizontal and vertical bone loss. The mean vertical bone loss of the buccal bone plate was significantly lower in Tx 4 than in the other groups, while no statistical significant differences could be detected among the groups in the horizontal dimension. Overbuilding the buccal aspect in combination with socket preservation does not seem to be a suitable technique to compensate for the alterations after tooth extraction.

  18. Vertical gradients and seasonal variation in stem CO2 efflux within a Norway spruce stand.

    PubMed

    Tarvainen, Lasse; Räntfors, Mats; Wallin, Göran

    2014-05-01

    Stem CO2 efflux is known to vary seasonally and vertically along tree stems. However, annual tree- and stand-scale efflux estimates are commonly based on measurements made only a few times a year, during daytime and at breast height. In this study, the effect of these simplifying assumptions on annual efflux estimates and their influence on the estimates of the importance of stems in stand-scale carbon cycling are evaluated. In order to assess the strength of seasonal, diurnal and along-stem variability in CO2 efflux, half-hourly measurements were carried out at three heights on three mature Norway spruce (Picea abies (L.) Karst.) trees over a period of 3 years. Making the common assumption of breast height efflux rates being representative of the entire stem was found to result in underestimations of 10-17% in the annual tree-scale CO2 efflux. Upscaling using only daytime measurements from breast height increased the underestimation to 15-20%. Furthermore, the results show that the strength of the vertical gradient varies seasonally, being strongest in the early summer and non-existent during the cool months. The observed seasonality in the vertical CO2 efflux gradient could not be explained by variation in stem temperature, temperature response of the CO2 efflux (Q10), outer-bark permeability, CO2 transport in the xylem or CO2 release from the phloem. However, the estimated CO2 concentration immediately beneath the bark was considerably higher in the upper stem during the main period of diameter growth, coinciding with the strongest vertical efflux gradient. These results suggest that higher growth rates in the upper stem are the main cause for the observed vertical variation in the stem CO2 effluxes. Furthermore, the results indicate that accounting for the vertical efflux variation is essential for assessments of the importance of stems in stand-scale carbon cycling. © The Author 2014. Published by Oxford University Press. All rights reserved.

  19. The effect of the heights and thicknesses of the remaining root segments on buccal bone resorption in the socket-shield technique: An experimental study in dogs.

    PubMed

    Tan, Zhen; Kang, Jian; Liu, Wenjia; Wang, Hang

    2018-06-01

    To date only a few studies have been done on the use of the socket-shield technique for preserving the resorption of the buccal bone in aesthetically sensitive sites. Besides, there have been no further studies on the effect of the heights and thicknesses of the remaining root segments on buccal bone resorption when using this method. The aim of this study was to evaluate the effect of different heights and thicknesses of the remaining root segments on bone resorption in the socket-shield technique. Four healthy female beagle dogs were used in this study. The third premolar (P3) and the fourth premolar (P4) on both sides of the mandible were hemisected in the buccal-lingual direction, and the clinical crown of the distal root was beheaded. In the experimental groups, the roots were worn down in the apical direction until they were located at the buccal crestal level (Group A) or 1 mm higher than that level (Group B). In the control group, the distal root segments were extracted. Then, implant placement was performed into the distal root. After 3 months of healing, the specimens were prepared for histological diagnosis. There was no difference between Group A and Group B when using the socket-shield technique, but the results of both groups were better than those of the control group. The height of the root segments has little effect on the bone absorption of alveolar bone, while the bone absorption was strongly influenced by the thickness of the root segments. More precisely, the absorption may decrease if the thickness of the root fragment increases, when the thickness of the root plate is in the 0.5-1.5 mm range. © 2018 Wiley Periodicals, Inc.

  20. Longitudinal changes in tooth/single-implant relationship and bone topography: an 8-year retrospective analysis.

    PubMed

    Chang, Moontaek; Wennström, Jan L

    2012-06-01

    To evaluate longitudinal changes in tooth/implant relationship and bone topography at single implants with a microthreaded, conical marginal portion (Astra Tech ST® implants, Astra Tech AB, Mölndal, Sweden). Thirty-one subjects with single implant-supported restorations in the esthetic zone were included. Radiographs obtained at crown installation and 1, 5, and 8 years of follow-up were analyzed with regard to changes in (1) bone level at the implant and adjacent teeth and (2) vertical position of adjacent teeth relative to the single implant. The mean marginal bone loss amounted to 0.1 mm at both implants and adjacent teeth during the 8 years of follow-up. Regression analysis failed to identify significant explanatory factors for observed variance in bone level change at the adjacent tooth surfaces. Vertical change in position of the teeth relative to the implants was more frequent and significantly greater in incisor compared with premolar tooth region but not associated with gender or age. The marginal bone level at teeth adjacent to single implants with a microthreaded conical marginal part was not influenced by horizontal and vertical tooth-implant distances. Continuous eruption of adjacent teeth may result in infraocclusal positioning of a single-implant restoration. © 2010 Wiley Periodicals, Inc.

  1. Cancellous bone block allografts for the augmentation of the anterior atrophic maxilla.

    PubMed

    Nissan, Joseph; Mardinger, Ofer; Calderon, Shlomo; Romanos, George E; Chaushu, Gavriel

    2011-06-01

    Pre-implant augmentative surgery is a prerequisite in many cases in the anterior maxilla to achieve a stable, long-term esthetic final result. The aim of the present study was to evaluate the outcome of ridge augmentation with cancellous freeze-dried block bone allografts in the anterior atrophic maxilla followed by placement of dental implants. Thirty-one consecutive patients were included in the study. A bony deficiency of at least 3 mm horizontally and up to 3 mm vertically according to computerized tomography (CT) served as inclusion criteria. Sixty-three implants were inserted after a healing period of 6 months. Nineteen of sixty-three implants were immediately restored. Bone measurements were taken prior to bone augmentation, during implant placement, and at second-stage surgery. Forty-six cancellous allogeneic bone blocks were used. The mean follow-up was 34 ± 16 months. Mean bone gain was 5 ± 0.5 mm horizontally, and 2 ± 0.5 mm vertically. Mean buccal bone resorption was 0.5 ± 0.5 mm at implant placement, and 0.2 ± 0.2 mm at second-stage surgery. Mean bone thickness buccal to the implant neck was 2.5 ± 0.5 mm at implant placement, and 2.3 ± 0.2 mm at second-stage surgery. There was no evidence of vertical bone loss between implant placement and second-stage surgery. Block and implant survival rates were 95.6 and 98%, respectively. All patients received a fixed implant-supported prosthesis. Cancellous block allografts appear to hold promise for grafting the anterior atrophic maxilla. © 2009 Wiley Periodicals, Inc.

  2. The reliability of vertical jump tests between the Vertec and My Jump phone application.

    PubMed

    Yingling, Vanessa R; Castro, Dimitri A; Duong, Justin T; Malpartida, Fiorella J; Usher, Justin R; O, Jenny

    2018-01-01

    The vertical jump is used to estimate sports performance capabilities and physical fitness in children, elderly, non-athletic and injured individuals. Different jump techniques and measurement tools are available to assess vertical jump height and peak power; however, their use is limited by access to laboratory settings, excessive cost and/or time constraints thus making these tools oftentimes unsuitable for field assessment. A popular field test uses the Vertec and the Sargent vertical jump with countermovement; however, new low cost, easy to use tools are becoming available, including the My Jump iOS mobile application (app). The purpose of this study was to assess the reliability of the My Jump relative to values obtained by the Vertec for the Sargent stand and reach vertical jump (VJ) test. One hundred and thirty-five healthy participants aged 18-39 years (94 males, 41 females) completed three maximal Sargent VJ with countermovement that were simultaneously measured using the Vertec and the My Jump . Jump heights were quantified for each jump and peak power was calculated using the Sayers equation. Four separate ICC estimates and their 95% confidence intervals were used to assess reliability. Two analyses (with jump height and calculated peak power as the dependent variables, respectively) were based on a single rater, consistency, two-way mixed-effects model, while two others (with jump height and calculated peak power as the dependent variables, respectively) were based on a single rater, absolute agreement, two-way mixed-effects model. Moderate to excellent reliability relative to the degree of consistency between the Vertec and My Jump values was found for jump height (ICC = 0.813; 95% CI [0.747-0.863]) and calculated peak power (ICC = 0.926; 95% CI [0.897-0.947]). However, poor to good reliability relative to absolute agreement for VJ height (ICC = 0.665; 95% CI [0.050-0.859]) and poor to excellent reliability relative to absolute agreement for peak power (ICC = 0.851; 95% CI [0.272-0.946]) between the Vertec and My Jump values were found; Vertec VJ height, and thus, Vertec calculated peak power values, were significantly higher than those calculated from My Jump values ( p < 0.0001). The My Jump app may provide a reliable measure of vertical jump height and calculated peak power in multiple field and laboratory settings without the need of costly equipment such as force plates or Vertec. The reliability relative to degree of consistency between the Vertec and My Jump app was moderate to excellent. However, the reliability relative to absolute agreement between Vertec and My Jump values contained significant variation (based on CI values), thus, it is recommended that either the My Jump or the Vertec be used to assess VJ height in repeated measures within subjects' designs; these measurement tools should not be considered interchangeable within subjects or in group measurement designs.

  3. The reliability of vertical jump tests between the Vertec and My Jump phone application

    PubMed Central

    Castro, Dimitri A.; Duong, Justin T.; Malpartida, Fiorella J.; Usher, Justin R.; O, Jenny

    2018-01-01

    Background The vertical jump is used to estimate sports performance capabilities and physical fitness in children, elderly, non-athletic and injured individuals. Different jump techniques and measurement tools are available to assess vertical jump height and peak power; however, their use is limited by access to laboratory settings, excessive cost and/or time constraints thus making these tools oftentimes unsuitable for field assessment. A popular field test uses the Vertec and the Sargent vertical jump with countermovement; however, new low cost, easy to use tools are becoming available, including the My Jump iOS mobile application (app). The purpose of this study was to assess the reliability of the My Jump relative to values obtained by the Vertec for the Sargent stand and reach vertical jump (VJ) test. Methods One hundred and thirty-five healthy participants aged 18–39 years (94 males, 41 females) completed three maximal Sargent VJ with countermovement that were simultaneously measured using the Vertec and the My Jump. Jump heights were quantified for each jump and peak power was calculated using the Sayers equation. Four separate ICC estimates and their 95% confidence intervals were used to assess reliability. Two analyses (with jump height and calculated peak power as the dependent variables, respectively) were based on a single rater, consistency, two-way mixed-effects model, while two others (with jump height and calculated peak power as the dependent variables, respectively) were based on a single rater, absolute agreement, two-way mixed-effects model. Results Moderate to excellent reliability relative to the degree of consistency between the Vertec and My Jump values was found for jump height (ICC = 0.813; 95% CI [0.747–0.863]) and calculated peak power (ICC = 0.926; 95% CI [0.897–0.947]). However, poor to good reliability relative to absolute agreement for VJ height (ICC = 0.665; 95% CI [0.050–0.859]) and poor to excellent reliability relative to absolute agreement for peak power (ICC = 0.851; 95% CI [0.272–0.946]) between the Vertec and My Jump values were found; Vertec VJ height, and thus, Vertec calculated peak power values, were significantly higher than those calculated from My Jump values (p < 0.0001). Discussion The My Jump app may provide a reliable measure of vertical jump height and calculated peak power in multiple field and laboratory settings without the need of costly equipment such as force plates or Vertec. The reliability relative to degree of consistency between the Vertec and My Jump app was moderate to excellent. However, the reliability relative to absolute agreement between Vertec and My Jump values contained significant variation (based on CI values), thus, it is recommended that either the My Jump or the Vertec be used to assess VJ height in repeated measures within subjects’ designs; these measurement tools should not be considered interchangeable within subjects or in group measurement designs. PMID:29692955

  4. 49 CFR 38.73 - Doorways.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height. Vertical alignment may be accomplished by vehicle air suspension, automatic ramps or lifts, or any combination. (2) Exception. New vehicles operating in existing stations may have a floor height within plus or...

  5. 47 CFR 78.33 - Special temporary authority.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... stage; (11) Type of emission; (12) Description of antenna to be used, including height. In the event that the proposed antenna installations will increase the height of any natural formation, or existing manmade structure, by more than 6.1 meters (20 feet), a vertical plan sketch showing the height of the...

  6. 49 CFR 38.73 - Doorways.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height. Vertical alignment may be accomplished by vehicle air suspension, automatic ramps or lifts, or any combination. (2) Exception. New vehicles operating in existing stations may have a floor height within plus or...

  7. 49 CFR 38.73 - Doorways.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height. Vertical alignment may be accomplished by vehicle air suspension, automatic ramps or lifts, or any combination. (2) Exception. New vehicles operating in existing stations may have a floor height within plus or...

  8. 49 CFR 38.73 - Doorways.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height. Vertical alignment may be accomplished by vehicle air suspension, automatic ramps or lifts, or any combination. (2) Exception. New vehicles operating in existing stations may have a floor height within plus or...

  9. Accuracy of a vertical jump contact mat for determining jump height and flight time.

    PubMed

    Whitmer, Tyler D; Fry, Andrew C; Forsythe, Charles M; Andre, Matthew J; Lane, Michael T; Hudy, Andrea; Honnold, Darric E

    2015-04-01

    Several devices are available to measure vertical jump (VJ) height based on flight time, VJ reach height, or ground reaction forces. The purpose of this study was to determine the accuracy of a VJ mat for measuring flight time and VJ height compared with a VJ tester or a force plate. Seventeen men and 18 women (X ± SD; age = 20.9 ± 0.7 years, height = 176.1 ± 0.9 cm, weight = 72.6 ± 13.5 kg) served as subjects. Subjects performed counter-movement vertical jumps while standing on both a force plate (1,000 Hz) and a VJ mat. A Vertec VJ tester was used to measure jump reach. Compared with the force plate, the VJ mat reported greater VJ height (VJ mat = 0.50 ± 0.12 m, force plate = 0.34 ± 0.10 m) and flight time (VJ mat = 0.629 ± 0.078 seconds, force plate = 0.524 ± 0.077 seconds). Comparison of VJ heights from the VJ mat and the Vertec revealed no significant differences (Vertec = 0.48 ± 0.11 m). Regression analyses indicated strong relationships between testing methods and suggested that high VJ performances may be underestimated with the VJ mat. This particular VJ mat compared favorably with the Vertec but not the force plate. It seems that the different flight times derived from the VJ mat may permit the VJ mat to be in closer agreement with VJ heights from the Vertec. Also, the VJ mat may not be an appropriate tool for assessing high VJ performances (i.e., ≥0.70 m; ≈28 inches). Practitioners and researchers using similar VJ mats may not obtain accurate flight times and may underestimate high performers.

  10. Clinical use of the resorbable bioscaffold poly lactic co-glycolic acid (PLGA) in post-extraction socket for maintaining the alveolar height: A prospective study.

    PubMed

    Hoda, Nadeemul; Saifi, Aamir Malick; Giraddi, Girish B

    2016-01-01

    A common sequel of tooth extraction is alveolar bone resorption. It makes the placement of dental implants difficult and creates an esthetic problem for the fabrication of conventional prostheses. Therefore, alveolar bone following tooth extraction should be preserved. The present prospective study was conducted to evaluate the efficacy of the resorbable bioscaffold poly lactic co-glycolic acid (PLGA) in maintaining the alveolar height in post-extraction socket. 20 patients were selected based on inclusion and exclusion criteria and were randomly divided into two groups: cases and control comprising of 10 patients each. Atraumatic tooth extraction was done in all patients. PLGA bioscaffold was placed in cases and socket was closed with 3-0 vicryl. In control group, socket was directly closed with 3-0 vicryl. The patients were kept on follow-up and complications such as dry socket, pain, and swelling were recorded. IOPA were taken at 1st, 4th, 12th, and 24th week to record changes in the height of alveolar bone. The radiographic measurements were compared and the differences were statistically analyzed. Reduction in alveolar bone height after placement of PLGA bioscaffold was significantly less in cases as compared to controls at 4th, 12th, and 24th week following extraction. No complications were observed throughout the follow-up period. PLGA scaffold significantly reduces bone resorption. Application is very simple and can be easily performed in a dental setup. However, PLGA scaffold adds significantly to the cost of treatment.

  11. --No Title--

    Science.gov Websites

    .vertical-bar{margin:1em 0 1em 0} .vertical-bar h2{background-color:#545454;color:#fff;padding:8px } .vertical-bar img.icon{background-color:#8CC63F;height:53px;margin-top:20px;margin-bottom:10px;padding:0 3px

  12. Tsunami Wave Run-up on a Vertical Wall in Tidal Environment

    NASA Astrophysics Data System (ADS)

    Didenkulova, Ira; Pelinovsky, Efim

    2018-04-01

    We solve analytically a nonlinear problem of shallow water theory for the tsunami wave run-up on a vertical wall in tidal environment. Shown that the tide can be considered static in the process of tsunami wave run-up. In this approximation, it is possible to obtain the exact solution for the run-up height as a function of the incident wave height. This allows us to investigate the tide influence on the run-up characteristics.

  13. Effects of spine flexion and erector spinae maximal force on vertical squat jump height: a computational simulation study.

    PubMed

    Blache, Yoann; Monteil, Karine

    2015-03-01

    The purpose of this study was to evaluate the single and combined effects of initial spine flexion and maximal isometric force of the erector spinae on maximal vertical jump height during maximal squat jumping. Seven initial flexions of the 'thorax-head-arm' segment (between 20.1° and 71.6°) and five maximal isometric forces of the erector spinae (between 5600 and 8600 N) were tested. Thus, 35 squat jumps were simulated using a 2D simulation model of the musculoskeletal system. Vertical jump height varied at most about 0.094 and 0.021 m when the initial flexion of the 'thorax-head-arm' segment and the maximal force of the erector spinae were, respectively, maximal. These results were explained for the most part by the variation of total muscle work. The latter was mainly influenced by the work produced by the erector spinae which increased at most about 57 and 110 J when the initial flexion of the 'thorax-head-arm' segment and the maximal force of the erector spinae were, respectively, maximal. It was concluded that the increase in the initial flexion of the 'thorax-head-arm' segment and in the maximal isometric force of the erector spinae enables an increase in maximal vertical jump height during maximal squat jumping.

  14. Low bioavailable testosterone levels predict future height loss in postmenopausal women.

    PubMed

    Jassal, S K; Barrett-Connor, E; Edelstein, S L

    1995-04-01

    The objective of this study was to examine the relation of endogenous sex hormones to subsequent height loss in postmenopausal women, in whom height loss is usually a surrogate for osteoporotic vertebral fractures. This was a prospective, community-based study. The site chosen was Rancho Bernardo, an upper middle class community in Southern California. A total of 170 postmenopausal women participated, aged 55-80 years. None of them were taking exogenous estrogen between 1972 and 1974. Plasma was obtained for sex hormone and sex hormone-binding globulin (SHBG) assays. Estradiol/SHBG and testosterone/SHBG ratios were used to estimate biologically available hormone levels; bioavailable (non-SHBG-bound) testosterone was measured directly in 60 women. Height loss was based on height measurements taken 16 years apart. Height loss was strongly correlated with age (p = 0.001). These women lost an average 0.22 cm/year in height. Neither estrone nor estradiol levels were significantly and independently related to height loss. Both estimated bioavailable testosterone (testosterone/SHBG ratio) and measured bioavailable testosterone levels predicted future height loss (p = 0.02 and 0.08, respectively) independent of age, obesity, cigarette smoking, alcohol intake, and use of thiazides and estrogen. We conclude that bioavailable testosterone is an independent predictor of height loss in elderly postmenopausal women. The reduced height loss is compatible with a direct effect of testosterone on bone mineral density or bone remodeling.

  15. The effect of splinting implant-supported restorations on stress distribution of different crown-implant ratios and crown height spaces.

    PubMed

    Nissan, Joseph; Gross, Ora; Ghelfan, Oded; Priel, Ilan; Gross, Martin; Chaushu, Gavriel

    2011-12-01

    To assess whether splinting can counterbalance the detrimental effects of varying the crown-to-implant (C/I) ratio and crown height space (CHS) by decreasing nonaxial overload stresses. Three implants were inserted into a photoelastic block model. Two strain gauges were cemented onto the neck of each implant on the buccal and lingual aspects and provided a simultaneous direct reading of strain. Four groups of splinted cement-retained restorations with C/I ratios of 1:1, 1:1.5, 1:1.75, and 1:2 were used. CHSs were 10, 15, 17.5, and 20 mm, respectively. Fifteen static loadings were carried out simultaneously with 20-kg weights via a custom-built loading apparatus at 30° to the vertical axis. Occlusal force application at 30° showed a statistically significant increase in both buccal (1,911.65 ± 110 vs 3,252.06 ± 150) and palatal (35.58 ± 7 vs 286.85 ± 15) microstrain values as the C/I ratio increased from 1:1 to 1:1.5 (P < .001). Force application at 30° in cases with C/I ratios of 1:1.75 and 1:2 resulted in fracture of the abutment screw followed by dislodgement of the crowns. Failures were noted at a CHS of 15 mm or greater. In this biomechanical mode, splinting does not prevent prosthetic failure when the CHS is 15 mm or greater. Vertical bone augmentation is highly recommended in cases with a CHS of 15 mm or greater. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Five-class height-weight mean and SD system applying Estonian reference values of height-weight mean and SD for systematization of seventeen-year-old conscripts' anthropometric data.

    PubMed

    Lintsi, Mart; Kaarma, Helje; Aunapuu, Marina; Arend, Andres

    2007-03-01

    A study of 739 conscripts aged 17 years from the town of Tartu and from the Tartu county was performed. Height, weight, 33 anthropometric measurements and 12 skinfolds were measured. The data were classified into five height-weight mean and SD-classes applying the Estonian reference values for this age and sex (Grünberg et al. 1998). There were 3 classes with conformity between height and weight class: 1--small (small height and small weight), 2--medium (medium height and medium weight), 3--large (large height and large weight), 4--weight class dominating (pyknomorphic) and 5--height class dominating (leptomorphic). It was found, that in classes 1, 2 and 3 the height and weight increase was in accordance with the increase in all heights, breadths and depths, circumferences, skinfolds, body fat, muscle and bone mass. In class 4 circumferences, skinfolds, body fat and muscle mass were bigger. In class 5 all heights and the relative bone mass were bigger. The present investigation confirms the assumption that the five height-weight mean and SD five-class system applying the Estonian reference values for classifying the anthropometric variables is suitable for seventeen-year-old conscripts. As well the border values of 5%, 50% and 95% for every anthropometrical variable in the five-classes were calculated, which may be helpful for practical classifying.

  17. Histomorphometric study of tibia of rats exposed aboard American Spacelab Life Sciences 2 Shuttle Mission

    NASA Technical Reports Server (NTRS)

    Durnova, G.; Kaplansky, A.; Morey-Holton, E.

    1996-01-01

    Tibial bones of rats flown onboard the SLS-2 shuttle mission were studied. Trabecular bone parameters were investigated, including growth plate height, trabecular bone volume, thickness and number, and trabecular separation in the primary and secondary spongiosa. Several histomorphometric changes were noted, allowing researchers to conclude that exposure to microgravity resulted in osteopenia of spongy bone of tibial metaphysis. The roles of bone formation and bone resorption are discussed.

  18. Quantitative calcaneal ultrasound parameters and bone mineral density at final height in girls treated with depot gonadotrophin-releasing hormone agonist for central precocious puberty or idiopathic short stature.

    PubMed

    Kapteijns-van Kordelaar, Simone; Noordam, Kees; Otten, Barto; van den Bergh, Joop

    2003-11-01

    To evaluate the effect of gonadotrophin-releasing hormone (GnRH) agonist treatment on bone quality at final height, we studied girls with central precocious puberty (CPP) and with idiopathic short stature (ISS). A total of 25 Caucasian girls were included: group A (n=14) with idiopathic CPP (mean age at start 7.4 years) and group B (n=11) with ISS (mean age at start 11.7 years). Treatment duration was 3.8 and 1.7 years respectively. The quantitative ultrasound parameters (QUS) broadband ultrasound attenuation (BUA) and speed of sound (SOS) were measured at the calcaneus (UBIS 3000 device). Lumbar spine bone mineral density (BMD; L2-L4) was measured by dual energy X-ray absorptiometry (DXA) (Hologic QDR1000). Measurements were performed at final height and expressed as Z-scores corrected for bone age. Mean Z-scores of QUS parameters, areal BMD and volumetric BMD (BMDvol) were above -1 in both groups (group A: BUA Z-score -0.21, SOS Z-score -0.29, BMD Z-score 0.02, BMDvol Z-score 0.05, group B: BUA Z-score -0.93, SOS Z-score -0.40, BMD Z-score -0.86, BMDvol Z-score -0.68), although mean Z-scores of BUA and areal BMD in group B were significantly different from zero (P=0.03 and P=0.02 respectively). Mean Z-score BMDvol was not significantly different from zero (P=0.05), we found no significant difference between the groups for BMDvol (P=0.13). Although quantitative ultrasound parameters parameters and bone mineral density were normal in girls with central precocious puberty at final height after gonadotrophin-releasing hormone agonist treatment, mean Z-score for broadband ultrasound attenuation and areal bone mineral density were significantly different from zero and mean Z-score for volumetric bone mineral density was (just) not significantly different from zero in idiopathic short stature girls with normal puberty treated with gonadotrophin-releasing hormone agonists. Therefore we cannot say that this treatment is safe in these girls with regard to bone health.

  19. Influence of third-body particles originating from bone void fillers on the wear of ultra-high-molecular-weight polyethylene

    PubMed Central

    Cowie, Raelene M; Carbone, Silvia; Aiken, Sean; Cooper, John J; Jennings, Louise M

    2016-01-01

    Calcium sulfate bone void fillers are increasingly being used for dead space management in infected arthroplasty revision surgery. The presence of these materials as loose beads close to the bearing surfaces of joint replacements gives the potential for them to enter the joint becoming trapped between the articulating surfaces; the resulting damage to cobalt chrome counterfaces and the subsequent wear of ultra-high-molecular-weight polyethylene is unknown. In this study, third-body damage to cobalt chrome counterfaces was simulated using particles of the calcium sulfate bone void fillers Stimulan® (Biocomposites Ltd., Keele, UK) and Osteoset® (Wright Medical Technology, TN, USA) using a bespoke rig. Scratches on the cobalt chrome plates were quantified in terms of their density and mean lip height, and the damage caused by the bone void fillers was compared to that caused by particles of SmartSet GMV PMMA bone cement (DePuy Synthes, IN, USA). The surface damage from Stimulan® was below the resolution of the analysis technique used; SmartSet GMV caused 0.19 scratches/mm with a mean lip height of 0.03 µm; Osteoset® led to a significantly higher number (1.62 scratches/mm) of scratches with a higher mean lip height (0.04 µm). Wear tests of ultra-high-molecular-weight polyethylene were carried out in a six-station multi-axial pin on plate reciprocating rig against the damaged plates and compared to negative (highly polished) and positive control plates damaged with a diamond stylus (2 µm lip height). The wear of ultra-high-molecular-weight polyethylene was shown to be similar against the negative control plates and those damaged with third-body particles; there was a significantly higher (p < 0.001) rate of ultra-high-molecular-weight polyethylene wear against the positive control plates. This study showed that bone void fillers of similar composition can cause varying damage to cobalt chrome counterfaces. However, the lip heights of the scratches were not of sufficient magnitude to increase the wear of ultra-high-molecular-weight polyethylene above that of the negative controls. PMID:27312481

  20. Fourier Domain Optical Coherence Tomography With 3D and En Face Imaging of the Punctum and Vertical Canaliculus: A Step Toward Establishing a Normative Database.

    PubMed

    Kamal, Saurabh; Ali, Mohammad Javed; Ali, Mohammad Hasnat; Naik, Milind N

    2016-01-01

    To report the features of Fourier domain optical coherence tomography imaging of the normal punctum and vertical canaliculus. Prospective, interventional series of consecutive healthy and asymptomatic adults, who volunteered for optical coherence tomography imaging, were included in the study. Fourier domain optical coherence tomography images of the punctum and vertical canaliculus along with 3D and En face images were captured using the RTVue scanner with a corneal adaptor module and a wide-angled lens. Maximum punctal diameter, mid-canalicular diameter, and vertical canalicular height were calculated. Statistical analysis was performed using Pearson correlation test, and scatter plot matrices were analyzed. A total of 103 puncta of 52 healthy subjects were studied. Although all the images could depict the punctum and vertical canaliculus and all the desired measurements could be obtained, occasional tear debris within the canaliculus was found to be interfering with the imaging. The mean maximum punctal diameter, mid-canalicular diameter, and vertical canalicular height were recorded as 214.71 ± 73 μm, 125.04 ± 60.69 μm, and 890.41 ± 154.76 μm, respectively, with an insignificant correlation between them. The maximum recorded vertical canalicular height in all the cases was far less than the widely reported depth of 2 mm. High-resolution 3D and En face images provided a detailed topography of punctal surface and overview of vertical canaliculus. Fourier domain optical coherence tomography with 3D and En face imaging is a useful noninvasive modality to image the proximal lacrimal system with consistently reproducible high-resolution images. This is likely to help clinicians in the management of proximal lacrimal disorders.

  1. 14 CFR 31.27 - Strength.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... drop test height of 36 inches, or a drop test height that produces, upon impact, a velocity equal to the maximum vertical velocity determined in accordance with § 31.19, whichever is higher, must be used...

  2. 14 CFR 31.27 - Strength.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... drop test height of 36 inches, or a drop test height that produces, upon impact, a velocity equal to the maximum vertical velocity determined in accordance with § 31.19, whichever is higher, must be used...

  3. 14 CFR 31.27 - Strength.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... drop test height of 36 inches, or a drop test height that produces, upon impact, a velocity equal to the maximum vertical velocity determined in accordance with § 31.19, whichever is higher, must be used...

  4. Validity of two alternative systems for measuring vertical jump height.

    PubMed

    Leard, John S; Cirillo, Melissa A; Katsnelson, Eugene; Kimiatek, Deena A; Miller, Tim W; Trebincevic, Kenan; Garbalosa, Juan C

    2007-11-01

    Vertical jump height is frequently used by coaches, health care professionals, and strength and conditioning professionals to objectively measure function. The purpose of this study is to determine the concurrent validity of the jump and reach method (Vertec) and the contact mat method (Just Jump) in assessing vertical jump height when compared with the criterion reference 3-camera motion analysis system. Thirty-nine college students, 25 females and 14 males between the ages of 18 and 25 (mean age 20.65 years), were instructed to perform the countermovement jump. Reflective markers were placed at the base of the individual's sacrum for the 3-camera motion analysis system to measure vertical jump height. The subject was then instructed to stand on the Just Jump mat beneath the Vertec and perform the jump. Measurements were recorded from each of the 3 systems simultaneously for each jump. The Pearson r statistic between the video and the jump and reach (Vertec) was 0.906. The Pearson r between the video and contact mat (Just Jump) was 0.967. Both correlations were significant at the 0.01 level. Analysis of variance showed a significant difference among the 3 means F(2,235) = 5.51, p < 0.05. The post hoc analysis showed a significant difference between the criterion reference (M = 0.4369 m) and the Vertec (M = 0.3937 m, p = 0.005) but not between the criterion reference and the Just Jump system (M = 0.4420 m, p = 0.972). The Just Jump method of measuring vertical jump height is a valid measure when compared with the 3-camera system. The Vertec was found to have a high correlation with the criterion reference, but the mean differed significantly. This study indicates that a higher degree of confidence is warranted when comparing Just Jump results with a 3-camera system study.

  5. [Application and research progress of subtalar distraction bone block arthrodesis in treatment of calcaneus fracture malunion].

    PubMed

    Wang, Shanxi; Li, Jun; Huang, Fuguo; Liu, Lei

    2017-05-01

    To review the application and research progress of subtalar distraction bone block arth-rodesis in the treatment of calcaneus fracture malunion. The recent literature concerning the history, surgical technique, postoperative complication, indications, and curative effect of subtalar distraction arthrodesis with bone graft block interposition in the treatment of calcaneus fracture malunion was summarized and analyzed. Subtalar distraction bone block arthrodesis is one of the main ways to treat calcaneus fracture malunion, including a combined surgery with subtalar arthrodesis and realignment surgery for hindfoot deformity using bone block graft. The advantage is on the base of subtalar joint fusion, through one-time retracting subtalar joint, the posterior articular surface of subtalar joint implants bone block can partially restore calcaneal height, thus improving the function of the foot. Compared with other calcaneal malunion treatments, subtalar distraction arthrodesis is effective to correct complications caused by calcaneus fracture malunion, and it can restore the height of talus and calcaneus, correct loss of talocalcaneal angle, and ease pain. Subtalar distraction bone block arthrodesis has made remarkable progress in the treatment of calcaneus fracture malunion, but it has the disadvantages of postoperative nonunion and absorption of bone block, so further study is needed.

  6. Inhibition of estrogen biosynthesis with a potent aromatase inhibitor increases predicted adult height in boys with idiopathic short stature: a randomized controlled trial.

    PubMed

    Hero, Matti; Norjavaara, Ensio; Dunkel, Leo

    2005-12-01

    In males as well as in females, estrogen is an essential regulator of bone maturation, growth plate fusion, and cessation of longitudinal growth. Therefore, an increase in predicted adult height (PAH) may be achieved in short boys by blocking estrogen biosynthesis. We tested the hypothesis that a decrease in the rate of bone maturation and an increase in PAH can be achieved in boys with idiopathic short stature (ISS) by the method of blocking estrogen biosynthesis with an aromatase inhibitor. Secondarily, we investigated the effects of aromatase inhibition on bone mineralization. This was a prospective, double-blind, randomized, placebo (Pl)-controlled clinical study. The study was performed at a university hospital out-patient clinic. Thirty-one boys, aged 9.0-14.5 yr, with ISS were studied. The boys were treated with the aromatase inhibitor letrozole (Lz; 2.5 mg/d) or Pl for 2 yr. The main outcome measure was the change in PAH after 24 months of treatment. PAH increased by 5.9 cm (P < 0.0001), and height SD score for bone age increased by 0.7 SD score (P < 0.0001) in the Lz-treated boys, whereas no changes occurred in the respective measures in Pl-treated boys. Areal bone mineral density of the lumbar spine and femoral neck, assessed by dual-energy x-ray absorptiometry, increased in a similar fashion in both groups during the treatment, whereas bone mineral apparent density increased only in those taking Lz (median increase, 4.3%; P = 0.009). Treatment with the aromatase inhibitor Lz delays bone maturation and improves PAH in boys with ISS. No adverse effects on bone mineralization were evident after 2 yr of treatment.

  7. Effect of the Earth's inner structure on the gravity in definitions of height systems

    NASA Astrophysics Data System (ADS)

    Tenzer, Robert; Foroughi, Ismael; Pitoňák, Martin; Šprlák, Michal

    2017-04-01

    In context of the vertical datum unification, the geoid-to-quasi-geoid separation has been of significant interest in recent years, because most of existing local vertical datums are realized in the system of either normal or orthometric heights. Nevertheless, the normal-orthometric heights are still used in many other countries where the normal gravity values along leveling lines were adopted instead of the observed gravity. Whereas the conversion between the orthometric and normal heights is defined by means of the mean gravity disturbances (i.e. differences between the mean values of the actual and normal gravity) along the plumbline within the topography, differences between the normal and normal-orthometric heights can be described by means of the surface gravity disturbances. Since the normal gravity field does not reflect the topographic masses and actual mass density distribution inside the Earth, the definition of gravity represents a principal aspect for a realization of particular vertical datum. To address this issue in this study, we investigate effects of the Earth's inner density structure on the surface and mean gravity disturbances, and discuss their impact on the vertical datum realization. These two gravity field quantities are computed globally with a spectral resolution complete to a spherical harmonic degree 2160 using the global gravity, terrain, ice-thickness, inland bathymetry and crustal structure models. Our results reveal that both, the surface and mean gravity disturbances mostly comprise the gravitational signal of topography and masses distributed below the geoid surface. Moreover, in polar areas, a significant contribution comes from large glaciers. In contrast, the contributions of anomalous density distribution within the topography attributed to major lakes, sediments and bedrock density variations are much less pronounced. We also demonstrate that the mean gravity disturbances within the topography are significantly modified compared to the corresponding surface values mainly due to topographic elevation and terrain geometry as well as the presence of large glaciers in polar regions. Changes of the vertical gravity gradient within the topography attributed to the masses distributed below the geoid (dominated mainly by the isostatic signature and the long-wavelength gravitational signature of deep mantle density heterogeneities) are, on the other hand, relatively small. Despite differences between the normal and normal-orthometric heights could directly be assessed from the surface gravity disturbances only when taken along leveling lines with information about the spirit leveling height differences, our results indicate that differences between these two height systems can be significant.

  8. [Metacarpophalangeal and carpal numeric indices to calculate bone age and predict adult size].

    PubMed

    Ebrí Torné, B; Ebrí Verde, I

    2012-04-01

    This work presents new numerical methods from the meta-carpal-phalangeal and carpal indexes, for calculating bone age. In addition, these new methods enable the adult height to be predicted using multiple regression equations. The longitudinal case series studied included 160 healthy children from Zaragoza, of both genders, aged between 6 months and 20 years, and studied annually, including the radiological study. For the statistical analysis the statistical package "Statistix", as well as the Excel program, was used. The new indexes are closely co-related to the chronological age, thus leading to predictive equations for the calculation of the bone age of children up to 20 years of age. In addition, it presents particular equations for up to 4 years of age, in order to optimise the diagnosis at these early ages. The resulting bones ages can be applied to numerical standard deviation tables, as well as to an equivalences chart, which directly gives us the ossification diagnosis. The predictive equations of adult height allow a reliable forecast of the future height of the studied child. These forecasts, analysed by the Student test did not show significant differences as regards the adult height that children of the case series finally achieved. The results can be obtained with a pocket calculator or through free software available for the reader. For the first time, and using a centre-developed and non-foreign methods, bones age standards and adult height predictive equations for the study of children, are presented. We invite the practitioner to use these meta-carpal-phalangeal and carpal methods in order to achieve the necessary experience to apply it to a healthy population and those with different disorders. Copyright © 2011 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  9. The morphology of human hyoid bone in relation to sex, age and body proportions.

    PubMed

    Urbanová, P; Hejna, P; Zátopková, L; Šafr, M

    2013-06-01

    Morphological aspects of the human hyoid bone are, like many other skeletal elements in human body, greatly affected by individual's sex, age and body proportions. Still, the known sex-dependent bimodality of a number of body size characteristics overshadows the true within-group patterns. Given the ambiguity of the causal effects of age, sex and body size upon hyoid morphology the present study puts the relationship between shape of human hyoid bone and body proportions (height and weight) under scrutiny of a morphological study. Using 211 hyoid bones and landmark-based methods of geometric morphometrics, it was shown that the size of hyoid bones correlated positively with measured body dimensions but showed no correlation if the individual's sex was controlled for. For shape variables, our results revealed that hyoid morphology is clearly related to body size as expressed in terms of the height and weight. Yet, the hyoid shape was shown to result primarily from the sex-related bimodal distribution of studied body size descriptors which, in the case of the height-dependent model, exhibited opposite trends for males and females. Apart from the global hyoid shape given by spatial arrangements of the greater horns, body size dependency was translated into size and position of the hyoid body. None of the body size characters had any impact on hyoid asymmetry. Ultimately, sexually dimorphic variation was revealed for age-dependent changes in both size and shape of hyoid bones as male hyoids tend to be more susceptible to modifications with age than female bones. Copyright © 2013 Elsevier GmbH. All rights reserved.

  10. Hypohydration Reduces Vertical Ground Reaction Impulse But Not Jump Height

    DTIC Science & Technology

    2010-01-01

    countermovement jump from a 660 9 660 9 60 mm dual force plate plat- form (Leonardo v3.07, Orthometrix, Inc.) connected to a PC for the purpose of collecting... force data and calculating jump height (described below). Subjects stood still on the platform with one foot on each force plate for approxi- mately 10...study examined vertical jump performance using a force platform and weighted vest to determine why hypohydration (~4% body mass) does not improve jump

  11. Overdenture retaining bar stress distribution: a finite-element analysis.

    PubMed

    Caetano, Conrado Reinoldes; Mesquita, Marcelo Ferraz; Consani, Rafael Leonardo Xediek; Correr-Sobrinho, Lourenço; Dos Santos, Mateus Bertolini Fernandes

    2015-05-01

    Evaluate the stress distribution on the peri-implant bone tissue and prosthetic components of bar-clip retaining systems for overdentures presenting different implant inclinations, vertical misfit and framework material. Three-dimensional models of a jaw and an overdenture retained by two implants and a bar-clip attachment were modeled using specific software (SolidWorks 2010). The studied variables were: latero-lateral inclination of one implant (-10°, -5°, 0°, +5°, +10°); vertical misfit on the other implant (50, 100, 200 µm); and framework material (Au type IV, Ag-Pd, Ti cp, Co-Cr). Solid models were imported into mechanical simulation software (ANSYS Workbench 11). All nodes on the bone's external surface were constrained and a displacement was applied to simulate the settling of the framework on the ill-fitted component. Von Mises stress for the prosthetic components and maximum principal stress to the bone tissue were evaluated. The +10° inclination presented the worst biomechanical behavior, promoting the highest stress values on the bar framework and peri-implant bone tissue. The -5° group presented the lowest stress values on the prosthetic components and the lowest stress value on peri-implant bone tissue was observed in -10°. Increased vertical misfit caused an increase on the stress values in all evaluated structures. Stiffer framework materials caused a considerable stress increase in the framework itself, prosthetic screw of the fitted component and peri-implant bone tissue. Inclination of one implant associated with vertical misfit caused a relevant effect on the stress distribution in bar-clip retained overdentures. Different framework materials promoted increased levels of stress in all the evaluated structures.

  12. SAGE III L2 Monthly Cloud Presence Data (Binary)

    Atmospheric Science Data Center

    2016-06-14

    ... degrees South Spatial Resolution:  1 km vertical Temporal Coverage:  02/27/2002 - 12/31/2005 ... Parameters:  Cloud Amount/Frequency Cloud Height Cloud Vertical Distribution Order Data:  Search and ...

  13. Measurements of aerosol layer height and vertical profiles by lidar over Jinhua City

    NASA Astrophysics Data System (ADS)

    Yu, Siqi; Liu, Dong; Wang, Zhenzhu; Xu, Jiwei; Tian, Xiaomin; Wu, Decheng; Xie, Chenbo; Wang, Yingjian

    2018-03-01

    The vertical distribution of the aerosol layers is depicted by using the lidar data in Jinhua city from 2013 to 2014. The lidar installed in Jinhua is a dual-wavelength Mie polarization Raman lidar. Aerosol layers are searched through gradient method. At the same time, HYSPLIT model is used to tracing the aerosol trajectories. The results show that different heights of aerosol layers have different transportation route. By a case study, the lidar data on December 30, 2013 and May 1, 2014 reveal several vertical aerosol layers. According to the 24-hour backward trajectory of HYSPLIT model, different aerosol layers comes from different places, and this may relate to the winter monsoon in China.

  14. 16 CFR 1509.3 - Crib-side height.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Crib-side height. 1509.3 Section 1509.3... REQUIREMENTS FOR NON-FULL-SIZE BABY CRIBS § 1509.3 Crib-side height. (a) With the mattress support in its highest adjustable position and the crib side in its lowest adjustable position, the vertical distance...

  15. 16 CFR 1509.3 - Crib-side height.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Crib-side height. 1509.3 Section 1509.3... REQUIREMENTS FOR NON-FULL-SIZE BABY CRIBS § 1509.3 Crib-side height. (a) With the mattress support in its highest adjustable position and the crib side in its lowest adjustable position, the vertical distance...

  16. 77 FR 53141 - Drawbridge Operation Regulation; Columbia River, Vancouver, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-31

    ... lift-spans. This deviation allows height-restricted lifts which will reduce the vertical clearance... which cross the Columbia River at mile 106.5 only be required to lift to a reduced height of 130 feet above Columbia River Datum for a 30 day period. The height restricted lifts are necessary to facilitate...

  17. 49 CFR 38.53 - Doorways.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height under all normal passenger load conditions. Vertical alignment may be... vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the...

  18. 49 CFR 38.53 - Doorways.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height under all normal passenger load conditions. Vertical alignment may be... vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the...

  19. 49 CFR 38.53 - Doorways.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height under all normal passenger load conditions. Vertical alignment may be... vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the...

  20. 49 CFR 38.53 - Doorways.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height under all normal passenger load conditions. Vertical alignment may be... vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the...

  1. Medium-Term Function of a 3D Printed TCP/HA Structure as a New Osteoconductive Scaffold for Vertical Bone Augmentation: A Simulation by BMP-2 Activation

    PubMed Central

    Moussa, Mira; Carrel, Jean-Pierre; Scherrer, Susanne; Cattani-Lorente, Maria; Wiskott, Anselm; Durual, Stéphane

    2015-01-01

    Introduction: A 3D-printed construct made of orthogonally layered strands of tricalcium phosphate (TCP) and hydroxyapatite has recently become available. The material provides excellent osteoconductivity. We simulated a medium-term experiment in a sheep calvarial model by priming the blocks with BMP-2. Vertical bone growth/maturation and material resorption were evaluated. Materials and methods: Titanium hemispherical caps were filled with either bare- or BMP-2 primed constructs and placed onto the calvaria of adult sheep (n = 8). Histomorphometry was performed after 8 and 16 weeks. Results: After 8 weeks, relative to bare constructs, BMP-2 stimulation led to a two-fold increase in bone volume (Bare: 22% ± 2.1%; BMP-2 primed: 50% ± 3%) and a 3-fold decrease in substitute volume (Bare: 47% ± 5%; BMP-2 primed: 18% ± 2%). These rates were still observed at 16 weeks. The new bone grew and matured to a haversian-like structure while the substitute material resorbed via cell- and chemical-mediation. Conclusion: By priming the 3D construct with BMP-2, bone metabolism was physiologically accelerated, that is, enhancing vertical bone growth and maturation as well as material bioresorption. The scaffolding function of the block was maintained, leaving time for the bone to grow and mature to a haversian-like structure. In parallel, the material resorbed via cell-mediated and chemical processes. These promising results must be confirmed in clinical tests.

  2. Amount of smoking, pulmonary function, and bone mineral density in middle-aged Korean men: KNHANES 2008-2011.

    PubMed

    Lee, Ji Hyun; Hong, A Ram; Kim, Jung Hee; Kim, Kyoung Min; Koo, Bo Kyung; Shin, Chan Soo; Kim, Sang Wan

    2018-01-01

    Smoking induces bone loss; however, data on the relationship between smoking history and bone mineral density (BMD) are lacking. Age and pulmonary function can affect BMD. We investigated the relationships among pack-years (PYs) of smoking, pulmonary function, and BMD in middle-aged Korean men (50-64 years old). This cross-sectional study used data from the Korean National Health and Nutrition Examination Survey, 2008-2011. All participants underwent BMD measurements using dual energy X-ray absorptiometry and pulmonary function tests using standardized spirometry. In total, 388 never-smokers and 1088 ever-smokers were analyzed. The number of PYs of smoking was negatively correlated with total hip BMD (r = -0.088; P = 0.004) after adjusting for age, height, and weight. Ever-smokers were classified into 3 groups according to PYs of smoking. The highest tertile (n = 482) exhibited significantly lower total hip bone mass than the lowest tertile (n = 214) after adjusting for confounding factors (age, height, weight, forced expiratory volume in 1 s (FEV 1 ), alcohol consumption, physical activity, and vitamin D levels) that could affect bone metabolism (P = 0.003). In conclusion, smoking for >30 PYs was significantly associated with low hip BMD after adjusting for pulmonary function in middle-aged Korean men. Long-term smoking may be a risk factor for bone loss in middle-aged men independent of age, height, weight, and pulmonary function.

  3. Abutment height influences the effect of platform switching on peri-implant marginal bone loss.

    PubMed

    Galindo-Moreno, Pablo; León-Cano, Ana; Monje, Alberto; Ortega-Oller, Inmaculada; O'Valle, Francisco; Catena, Andrés

    2016-02-01

    The purpose was to radiographically analyze and compare the marginal bone loss (MBL) between implants with different mismatching distance and to study the influence of the prosthetic abutment height on the MBL in association with the related mismatching distances. This retrospective study included 108 patients in whom 228 implants were placed, 180 with diameter of 4.5 mm and 48 with diameter of 5 mm. All patients received OsseoSpeed™ implants with internal tapered conical connection (Denstply Implants). Different mismatching distances were obtained, given that all implants were loaded with the same uni-abutment type (Lilac; Denstply Implants). Data were gathered on age, gender, bone substratum, smoking habits, previous history of periodontitis, and prosthetic features. MBL was analyzed radiographically at 6 and 18 months post-loading. Mixed linear analysis of mesial and distal MBL values yielded significant effects of abutment, implant diameter, follow-up period, bone substratum, smoking, and abutment × time interaction. MBL was greater at 18 vs. 6 months, for short vs. long abutments, for grafted vs. pristine bone, for a heavier smoking habit, and for implants with a diameter of 5.0 vs. 4.5 mm. Greater mismatching does not minimize the MBL; abutment height, smoking habit, and bone substratum may play a role in the MBL over the short- and medium term. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. [Triptorelin therapy in girls with central precocious puberty increases body mass index].

    PubMed

    Martín Díaz, M J; Soriano Guillén, L; Muñoz Calvo, M T; Pozo Román, J; Argente Oliver, J

    2006-11-01

    The most important complications of central precocious puberty (CPP) in girls are loss of height and multiple psychosocial problems. To study the effect of triptorelin therapy in a cohort of girls with CPP. Thirty-four girls diagnosed with organic or idiopathic CPP and treated with monthly triptorelin were studied. Age, height in standard deviation (SD), bone age (Greulich and Pyle), height prediction (Bayle-Pinneau), body mass index (BMI) in SD, uterine size (pelvic ultrasound), target height, cranial magnetic resonance imaging, triptorelin dose, and treatment duration were studied. Triptorelin produced a statistically significant reduction in growth velocity and an increase in BMI after 1 year of therapy and these changes were maintained after discontinuation of therapy. Adult height in these patients was in accordance with their target genetic height, as well as with their predicted height according to the method of Bayley-Pinneau. No significant differences were found between age of menarche in our patients and in controls. Adult height in patients with organic CPP was significantly lower than that in patients with idiopathic CPP. 1. Triptorelin can increase BMI in girls with CPP. 2. The presence of an organic cause in patients with CPP worsens the prognosis for adult height. 3. The Bayley-Pinneau prediction method for "average" bone age is useful for establishing a prognosis of adult height in girls with CPP treated with triptorelin.

  5. Long-Bone Injury Criteria for Use with the Articulated Total Body Model

    DTIC Science & Technology

    1981-01-01

    bone - human, canine, bovine, etc.; condition of bone - dry, wet , embalmed , fresh; subject variations - height, weight, health, sex, age, etc; whole bone...stress strain curves ob- tained by McElhaney for various strain rates in compression. This is for embalmed human compact bone. Ultimate stress, ultimate...reported for fresh human bone of 25,000 psi (see Table 1). Recall that the McElhaney data is from embalmed subjects. If it is assumed, for lack of any real

  6. 49 CFR 572.102 - Drop test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... surface when the midsagittal plane is vertical. (4) Drop the headform from the specified height by means... test. (a) When the headform is dropped from a height of 14.8 inches in accordance with paragraph (b) of...

  7. Automatic estimation of dynamics of ionospheric disturbances with 1–15 minute lifetimes as derived from ISTP SB RAS fast chirp-ionosonde data

    NASA Astrophysics Data System (ADS)

    Berngardt, Oleg; Bubnova, Tatyana; Podlesnyi, Aleksey

    2018-03-01

    We propose and test a method of analyzing ionograms of vertical ionospheric sounding, which is based on detecting deviations of the shape of an ionogram from its regular (averaged) shape. We interpret these deviations in terms of reflection from the electron density irregularities at heights corresponding to the effective height. We examine the irregularities thus discovered within the framework of a model of a localized uniformly moving irregularity, and determine their characteristic parameters: effective heights and observed vertical velocities. We analyze selected experimental data for three seasons (spring, winter, autumn) obtained nearby Irkutsk with a fast chirp ionosonde of ISTP SB RAS in 2013-2015. The analysis of six days of observations conducted in these seasons has shown that in the observed vertical drift of the irregularities there are two characteristic distributions: wide velocity distribution with nearly 0 m/s mean and with the standard deviation of ∼250 m/s and narrow distribution with nearly -160 m/s mean. The analysis has demonstrated the effectiveness of the proposed algorithm for the automatic analysis of vertical sounding data with high repetition rate.

  8. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.

    PubMed

    Merıç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; özden, Ahmet Utku

    2011-11-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone around the implants supporting cantilever fixed partial dentures (CFPDs) as well as in the implant-abutment complex and superstructures. The three-dimensional finite element method was selected to evaluate the stress distribution. CFPDs which was supported by microthread collar structured (MCS) and non-microthread collar structured (NMCS) implants was modeled; 300 N vertical, 150 N oblique and 60 N horizontal forces were applied to the models separately. The stress values in the bone, implant-abutment complex and superstructures were calculated. In the MCS model, higher stresses were located in the cortical bone and implant-abutment complex in the case of vertical load while decreased stresses in cortical bone and implant-abutment complex were noted within horizontal and oblique loading. In the case of vertical load, decreased stresses have been noted in cancellous bone and framework. Upon horizontal and oblique loading, a MCS model had higher stress in cancellous bone and framework than the NMCS model. Higher von Mises stresses have been noted in veneering material for NMCS models. It has been concluded that stress distribution in implant-supported CFPDs correlated with the macro design of the implant collar and the direction of applied force.

  9. Extraction and height estimation of artificial vertical structures based on the wrapped interferometric phase difference within their layovers

    NASA Astrophysics Data System (ADS)

    Uemoto, Jyunpei; Nadai, Akitsugu; Kojima, Shoichiro; Kobayashi, Tatsuharu; Umehara, Toshihiko; Matsuoka, Takeshi; Uratsuka, Seiho; Satake, Makoto

    2018-05-01

    The geometric modulation of synthetic aperture radar (SAR) imagery such as radar shadow, foreshortening, and layover often complicates image interpretation while it contains useful information about targets. Recently, some methods for automatic building detection utilizing a peculiar pattern of phase differences (PDs) within building layovers on SAR interferograms have been proposed. One of the merits of these methods is the capability to detect buildings even taller than the height of ambiguity without incorporating any external data. In this paper, we propose a new method that has achieved the following improvements while maintaining the merit mentioned above. The first improvement is freedom from the dependence of target heights; without changing any parameters and thresholds, the proposed method can detect low-rise apartments to skyscrapers. The second one is the prevention of the false grouping of vertical structure constituents by considering relationships between their PDs. In addition, the method can measure the height of vertical structures without assuming their shape to be simple ones such as a parallelogram. These improvements have been verified by applying the method to real datasets acquired from an airborne X-band SAR. The quantitative assessment for apartment complexes has demonstrated the high performance of the method; the correctness and completeness are 94% and 83%, respectively. The mean error in the measured height is -0.2 m, while the standard deviation is 1.8 m. The verification using real datasets has revealed at the same time that the performance of the method can be degraded due to the crowdedness in dense urban areas including skyscrapers and owing to the poor discriminability between artificial vertical structures and trees. Overcoming these limitations is necessary in future studies.

  10. Canopy Height and Vertical Structure from Multibaseline Polarimetric InSAR: First Results of the 2016 NASA/ESA AfriSAR Campaign

    NASA Astrophysics Data System (ADS)

    Lavalle, M.; Hensley, S.; Lou, Y.; Saatchi, S. S.; Pinto, N.; Simard, M.; Fatoyinbo, T. E.; Duncanson, L.; Dubayah, R.; Hofton, M. A.; Blair, J. B.; Armston, J.

    2016-12-01

    In this paper we explore the derivation of canopy height and vertical structure from polarimetric-interferometric SAR (PolInSAR) data collected during the 2016 AfriSAR campaign in Gabon. AfriSAR is a joint effort between NASA and ESA to acquire multi-baseline L- and P-band radar data, lidar data and field data over tropical forests and savannah sites to support calibration, validation and algorithm development in preparation for the NISAR, GEDI and BIOMASS missions. Here we focus on the L-band UAVSAR dataset acquired over the Lope National Park in Central Gabon to demonstrate mapping of canopy height and vertical structure using PolInSAR and tomographic techniques. The Lope site features a natural gradient of forest biomass from the forest-savanna boundary (< 100 Mg/ha) to dense undisturbed humid tropical forests (> 400 Mg/ha). Our dataset includes 9 long-baseline, full-polarimetric UAVSAR acquisitions along with field and lidar data from the Laser Vegetation Ice Sensor (LVIS). We first present a brief theoretical background of the PolInSAR and tomographic techniques. We then show the results of our PolInSAR algorithms to create maps of canopy height generated via inversion of the random-volume-over-ground (RVOG) and random-motion-over-ground (RVoG) models. In our approach multiple interferometric baselines are merged incoherently to maximize the interferometric sensitivity over a broad range of tree heights. Finally we show how traditional tomographic algorithms are used for the retrieval of the full vertical canopy profile. We compare our results from the different PolInSAR/tomographic algorithms to validation data derived from lidar and field data.

  11. Relationship between physical fitness at the end of pre-season and the in-season game performance in Japanese female professional baseball players.

    PubMed

    Watanabe, Yuya; Yamada, Yosuke; Yoshida, Tsukasa; Matsui, Tomoyuki; Seo, Kazuya; Azuma, Yoshikazu; Hiramoto, Machiko; Miura, Yuichiro; Fukushima, Hideaki; Shimazu, Akito; Eto, Toshiaki; Saotome, Homare; Kida, Noriyuki; Morihara, Toru

    2017-10-30

    This study examined anthropometric and fitness profiles of Japanese female professional baseball players and investigated the relationship between players' physical fitness and in-season game performance. Fifty-seven players who were registered in the Japan Women's Baseball League (JWBL) participated. Height, weight, grip strength, back strength, knee-extension and -flexion strength, hamstring extensibility, vertical jump height, and horizontal jump distance were measured at pre-season (February and March) in 2013. Game performance during the 2013 season (March to November) was obtained from official JWBL statistics. Vertical jump height showed significant positive correlations with individual performance records [e.g., total bases (r = 0.551), slugging percentage (r = 0.459), and stolen bases (r = 0.442)]. Similar relationships were observed between horizontal jump distance and performance statistics in most cases. In contrast, grip, back, and lower-limb strength, and hamstring extensibility were not significantly correlated with game performance. Stepwise regression analysis selected vertical jump height as an independent variable, significantly correlating with several game performance measures (e.g., total bases: adjusted R = 0.257). Also, vertical jump height and body mass index were identified as independent variables significantly associated with stolen bases (adjusted R = 0.251). Maximal jump performance, rather than simple isometric muscle strength or flexibility, is a good performance test that can be used at the end of pre-season to predict in-season batting and stolen base performance. Our findings demonstrate the importance of constructing pre-season training programs to enhance lower-limb muscular power that is linked to successful in-season performance in female baseball players.

  12. Validity of the Jump-and-Reach Test in Subelite Adolescent Handball Players.

    PubMed

    Muehlbauer, Thomas; Pabst, Jan; Granacher, Urs; Büsch, Dirk

    2017-05-01

    Muehlbauer, T, Pabst, J, Granacher, U, and Büsch, D. Validity of the jump-and-reach test in subelite adolescent handball players. J Strength Cond Res 31(5): 1282-1289, 2017-The primary purpose of this study was to examine concurrent validity of the jump-and-reach (JaR) test using the Vertec system and a criterion device (i.e., Optojump system). In separate subanalyses, we investigated the influence of gym floor condition and athletes' sex on the validity of vertical jump height. Four hundred forty subelite adolescent female (n = 222, mean age: 14 ± 1 year, age range: 13-15 years) and male (n = 218, mean age: 15 ± 1 year, age range: 14-16 years) handball players performed the JaR test in gyms with region or point elastic floors. Maximal vertical jump height was simultaneously assessed using the Vertec and the Optojump systems. In general, significantly higher jump heights were obtained for the Vertec compared with the Optojump system (11.2 cm, Δ31%, Cohen's d = 2.58). The subanalyses revealed significantly larger jump heights for the Vertec compared with the Optojump system irrespective of gym floor condition and players' sex. The association between Optojump- and Vertec-derived vertical jump heights amounted to rP = 0.84, with a coefficient of determination (R) of 0.71. The subanalyses indicated significantly larger correlations in males (rP = 0.75, R = 0.56) than in females (rP = 0.63, R = 0.40). Yet, correlations were not significantly different between region (rP = 0.83, R = 0.69) as opposed to point elastic floor (rP = 0.87, R = 0.76). Our findings indicate that the 2 apparatuses cannot be used interchangeably. Consequently, gym floor and sex-specific regression equations were provided to estimate true (Optojump system) vertical jump height from Vertec-derived data.

  13. Integrated injury prevention program improves balance and vertical jump height in children.

    PubMed

    DiStefano, Lindsay J; Padua, Darin A; Blackburn, J Troy; Garrett, William E; Guskiewicz, Kevin M; Marshall, Stephen W

    2010-02-01

    Implementing an injury prevention program to athletes under age 12 years may reduce injury rates. There is limited knowledge regarding whether these young athletes will be able to modify balance and performance measures after completing a traditional program that has been effective with older athletes or whether they require a specialized program for their age. The purpose of this study was to compare the effects of a pediatric program, which was designed specifically for young athletes, and a traditional program with no program in the ability to change balance and performance measures in youth athletes. We used a cluster-randomized controlled trial to evaluate the effects of the programs before and after a 9-week intervention period. Sixty-five youth soccer athletes (males: n = 37 mass = 34.16 +/- 5.36 kg, height = 143.07 +/- 6.27 cm, age = 10 +/- 1 yr; females: n = 28 mass = 33.82 +/- 5.37 kg, height = 141.02 +/- 6.59 cm) volunteered to participate and attended 2 testing sessions in a research laboratory. Teams were cluster-randomized to either a pediatric or traditional injury prevention program or a control group. Change scores for anterior-posterior and medial-lateral time-to-stabilization measures and maximum vertical jump height and power were calculated from pretest and post-test sessions. Contrary with our original hypotheses, the traditional program resulted in positive changes, whereas the pediatric program did not result in any improvements. Anterior-posterior time-to-stabilization decreased after the traditional program (mean change +/- SD = -0.92 +/- 0.49 s) compared with the control group (-0.49 +/- 0.59 s) (p = 0.003). The traditional program also increased vertical jump height (1.70 +/- 2.80 cm) compared with the control group (0.20 +/- 0.20 cm) (p = 0.04). There were no significant differences between control and pediatric programs. Youth athletes can improve balance ability and vertical jump height after completing an injury prevention program. Training specificity appears to affect improvements and should be considered with future program design.

  14. Vertical structure of radar reflectivity in deep intense convective clouds over the tropics

    NASA Astrophysics Data System (ADS)

    Kumar, Shailendra; Bhat, G. S.

    2015-04-01

    This study is based on 10 years of radar reflectivity factor (Z) data derived from the TRMM Precipitation Radar (PR) measurements. We define two types of convective cells, namely, cumulonimbus towers (CbTs) and intense convective clouds (ICCs), essentially following the methodology used in deriving the vertical profiles of radar reflectivity (VPRR). CbT contains Z≥ 20 dBZ at 12 km height with its base height below 3 km. ICCs belong to the top 5% reflectivity population at 3 km and 8 km altitude. Regional differences in the vertical structure of convective cells have been explored for two periods, namely, JJAS (June, July, August and September) and JFM (January, February and March) months. Frequency of occurrences of CbTs and ICCs depend on the region. Africa and Latin America are the most productive regions for the CbTs while the foothills of Western Himalaya contain the most intense profiles. Among the oceanic areas, the Bay of Bengal has the strongest vertical profile, whereas Atlantic Ocean has the weakest profile during JJAS. During JFM months, maritime continent has the strongest vertical profile whereas western equatorial Indian Ocean has the weakest. Monsoon clouds lie between the continental and oceanic cases. The maximum heights of 30 and 40 dBZ reflectivities (denoted by MH30 and MH40, respectively) are also studied. MH40 shows a single mode and peaks around 5.5 km during both JJAS and JFM months. MH30 shows two modes, around 5 km and between 8 km and 10 km, respectively. It is also shown that certain conclusions such as the area/region with the most intense convective cells, depend of the reference height used in defining a convective cell.

  15. Gender, Vertical Height and Horizontal Distance Effects on Single-Leg Landing Kinematics: Implications for Risk of non-contact ACL Injury.

    PubMed

    Ali, Nicholas; Rouhi, Gholamreza; Robertson, Gordon

    2013-01-01

    There is a lack of studies investigating gender differences in whole-body kinematics during single-leg landings from increasing vertical heights and horizontal distances. This study determined the main effects and interactions of gender, vertical height, and horizontal distance on whole-body joint kinematics during single-leg landings, and established whether these findings could explain the gender disparity in non-contact anterior cruciate ligament (ACL) injury rate. Recreationally active males (n=6) and females (n=6) performed single-leg landings from a takeoff deck of vertical height of 20, 40, and 60 cm placed at a horizontal distance of 30, 50 and 70 cm from the edge of a force platform, while 3D kinematics and kinetics were simultaneously measured. It was determined that peak vertical ground reaction force (VGRF) and the ankle flexion angle exhibited significant gender differences (p=0.028, partial η(2)=0.40 and p=0.035, partial η(2)=0.37, respectively). Peak VGRF was significantly correlated to the ankle flexion angle (r= -0.59, p=0.04), hip flexion angle (r= -0.74, p=0.006), and trunk flexion angle (r= -0.59, p=0.045). Peak posterior ground reaction force (PGRF) was significantly correlated to the ankle flexion angle (r= -0.56, p=0.035), while peak knee abduction moment was significantly correlated to the knee flexion angle (r= -0.64, p=0.03). Rearfoot landings may explain the higher ACL injury rate among females. Higher plantar-flexed ankle, hip, and trunk flexion angles were associated with lower peak ground reaction forces, while higher knee flexion angle was associated with lower peak knee abduction moment, and these kinematics implicate reduced risk of non-contact ACL injury.

  16. Resistivity Distribution of Multicrystalline Silicon Ingot Grown by Directional Solidification

    NASA Astrophysics Data System (ADS)

    Sun, S. H.; Tan, Y.; Dong, W.; Zhang, H. X.; Zhang, J. S.

    2012-06-01

    The effects of impurities on the resistivity distribution and polarity of multicrystalline silicon ingot prepared by directional solidification were investigated in this article. The shape of the equivalence line of the resistivity in the vertical and cross sections was determined by the solid-liquid interface. Along the solidification height of silicon ingot, the conductive type changed from p-type in the lower part of the silicon ingot to n-type in the upper part of the silicon ingot. The resistivity in the vertical section of the silicon ingot initially increased along the height of the solidified part, and reached its maximum at the polarity transition position, then decreased rapidly along the height of solidified part and approached zero on the top of the ingot because of the accumulation of impurities. The variation of resistivity in the vertical section of the ingot has been proven to be deeply relevant to the distribution of Al, B, and P in the growth direction of solidification.

  17. Reference values of bone stiffness index and C-terminal telopeptide in healthy European children.

    PubMed

    Herrmann, D; Intemann, T; Lauria, F; Mårild, S; Molnár, D; Moreno, L A; Sioen, I; Tornaritis, M; Veidebaum, T; Pigeot, I; Ahrens, W

    2014-09-01

    Quantitative ultrasound measurements and bone metabolic markers can help to monitor bone health and to detect impaired skeletal development. Population-based reference values for children may serve as a basis for preventive measures to reduce the risk of osteoporosis and osteoporotic fractures in later life. This is the first paper providing age-, sex- and height-specific reference values for bone stiffness index (SI) and serum carboxy-terminal cross-linking telopeptide of type I collagen (CTX) in healthy, apparently prepubertal children. In the population-based IDEFICS baseline survey (2007-2008) and follow-up (2009-2010), 18,745 children from eight European countries were newly recruited. A total of 10,791 2-10.9-year-old and 1646 3-8.9-year-old healthy children provided data on SI of the right and left calcaneus and serum CTX, respectively. Furthermore, height and weight were measured. Percentile curves were calculated using the General Additive Model for Location Scale and Shape (GAMLSS) to model the distribution of SI and CTX depending on multiple covariates while accounting for dispersion, skewness, and the kurtosis of this distribution. SI was negatively associated with age and height in children aged 2-5 years, whereas a positive association was observed in children aged 6-10 years. The dip in SI occurred at older age for higher SI percentiles and was observed earlier in taller children than in smaller children. The CTX reference curves showed a linear-positive association with age and height. No major sex differences were observed for the SI and CTX reference values. These reference data lay the ground to evaluate bone growth and metabolism in prepubertal children in epidemiological and clinical settings. They may also inform clinical practice to monitor skeletal development and to assess adverse drug reactions during medical treatments.

  18. SAGE III L2 Monthly Cloud Presence Data (HDF-EOS)

    Atmospheric Science Data Center

    2016-06-14

    ... degrees South Spatial Resolution:  1 km vertical Temporal Coverage:  02/27/2002 - 12/31/2005 ... Parameters:  Cloud Amount/Frequency Cloud Height Cloud Vertical Distribution Order Data:  Search and ...

  19. Vertical tilts of tropospheric waves - Observations and theory

    NASA Technical Reports Server (NTRS)

    Ebisuzaki, Wesley

    1991-01-01

    Two methods are used to investigate the vertical tilts of planetary waves as functions of zonal wavenumber and frequency. The vertical tilts are computed by cross-spectral analysis of the geopotential heights at different pressures. In the midlatitude troposphere, the eastward-moving waves had a westward tilt with height, as expected, but the westward-moving waves with frequencies higher than 0.2/d showed statistically significant eastward vertical tilts. For a free Rossby wave, this implies that the Eliassen-Palm flux is downward along with its energy propagation. A downward energy propagation suggests an upper-level source of these waves. It is proposed that the eastward-tilting waves were forced by the nonlinear interaction of stationary waves and baroclinically unstable cyclone-scale waves. The predicted vertical tilt and phase speed were consistent with the observations. In addition, simulations of a general circulation model were analyzed. In the control run, eastward-tilting waves disappeared when the sources of stationary waves were removed. This is consistent with the present theory.

  20. Unification of Intercontinental Height Systems based on the Fixed Geodetic Boundary Value Problem - A Case Study in Spherical Approximation

    NASA Astrophysics Data System (ADS)

    Grombein, T.; Seitz, K.; Heck, B.

    2013-12-01

    In general, national height reference systems are related to individual vertical datums defined by specific tide gauges. The discrepancy of these vertical datums causes height system biases that range in an order of 1-2 m at a global scale. Continental height systems can be connected by spirit leveling and gravity measurements along the leveling lines as performed for the definition of the European Vertical Reference Frame. In order to unify intercontinental height systems, an indirect connection is needed. For this purpose, global geopotential models derived from recent satellite missions like GOCE provide an important contribution. However, to achieve a highly-precise solution, a combination with local terrestrial gravity data is indispensable. Such combinations result in the solution of a Geodetic Boundary Value Problem (GBVP). In contrast to previous studies, mostly related to the traditional (scalar) free GBVP, the present paper discusses the use of the fixed GBVP for height system unification, where gravity disturbances instead of gravity anomalies are applied as boundary values. The basic idea of our approach is a conversion of measured gravity anomalies to gravity disturbances, where unknown datum parameters occur that can be associated with height system biases. In this way, the fixed GBVP can be extended by datum parameters for each datum zone. By evaluating the GBVP at GNSS/leveling benchmarks, the unknown datum parameters can be estimated in a least squares adjustment. Beside the developed theory, we present numerical results of a case study based on the spherical fixed GBVP and boundary values simulated by the use of the global geopotential model EGM2008. In a further step, the impact of approximations like linearization as well as topographic and ellipsoidal effects is taken into account by suitable reduction and correction terms.

  1. The Effects of Caffeine on Vertical Jump Height and Execution in Collegiate Athletes.

    PubMed

    Bloms, Lucas P; Fitzgerald, John S; Short, Martin W; Whitehead, James R

    2016-07-01

    Bloms, LP, Fitzgerald, JS, Short, MW, and Whitehead, JR. The effects of caffeine on vertical jump height and execution in collegiate athletes. J Strength Cond Res 30(7): 1855-1861, 2016-Caffeine ingestion elicits a variety of physiological effects that may be beneficial to maximal-intensity exercise performance, although its effectiveness and physical mechanism of action enhancing ballistic task performance are unclear. The purpose of this study was to examine the effects of caffeine ingestion on vertical jump height and jump execution in Division I collegiate athletes. The study used a single-blind, randomized, crossover design. Athletes (n = 25) consumed either caffeine (5 mg·kg) or placebo. After a 60-minute waiting period, athletes performed 3 squat jumps (SJ) and 3 countermovement jumps (CMJ) while standing on a force platform. Jump height and execution variables were calculated from mechanography data. In comparison with placebo, caffeine increased SJ height (32.8 ± 6.2 vs. 34.5 ± 6.7 cm; p = 0.001) and CMJ height (36.4 ± 6.9 vs. 37.9 ± 7.4 cm; p = 0.001). Peak force (p = 0.032) and average rate of force development (p = 0.037) were increased during the CMJ in the caffeine trail compared with the control. Time to half peak force was the only execution variable improved with caffeine (p = 0.019) during the SJ. It seems that caffeine affects both height and execution of jumping. Our data indicate that the physical mechanism of jump enhancement is increased peak force production or rate of force development during jumping depending on technique. The physical mechanism of jump enhancement suggests that the ergogenic effects of caffeine may transfer to other ballistic tasks involving the lower-body musculature in collegiate athletes.

  2. Randomized Trial of Aromatase Inhibitors, Growth Hormone, or Combination in Pubertal Boys with Idiopathic, Short Stature

    PubMed Central

    Ross, Judith L.; Gagliardi, Priscila; Yu, Y. Miles; Hossain, Jobayer; Permuy, Joseph; Damaso, Ligeia; Merinbaum, Debbie; Singh, Ravinder J.; Gaete, Ximena; Mericq, Veronica

    2016-01-01

    Context: Growth of short children in puberty is limited by the effect of estrogen on epiphyseal fusion. Objectives: To compare: 1) the efficacy and safety of aromatase inhibitors (AIs) vs GH vs AI/GH on increasing adult height potential in pubertal boys with severe idiopathic short stature (ISS); and 2) differences in body composition among groups. Design: Randomized three-arm open-label comparator. Setting: Outpatient clinical research. Patients: Seventy-six pubertal boys [mean (SE) age, 14.1 (0.1) years] with ISS [height SD score (SDS), −2.3 (0.0)]. Intervention: Daily AIs (anastrozole or letrozole), GH, or AI/GH for 24–36 months. Outcomes: Anthropometry, bone ages, dual x-ray absorptiometry, spine x-rays, hormones, safety labs. Results: Height gain [mean (SE)] at 24 months was: AI, +14.0 (0.8) cm; GH, +17.1 (0.9) cm; AI/GH, +18.9 (0.8) cm (P < .0006, analysis of covariance). Height SDS was: AI, −1.73 (0.12); GH, −1.43 (0.14); AI/GH, −1.25 (0.12) (P < .0012). Those treated through 36 months grew more. Regardless of treatment duration, height SDS at near-final height [n = 71; age, 17.4 (0.2) years; bone age, 15.3 (0.1) years; height achieved, ∼97.6%] was: AI, −1.4 (0.1); GH, −1.4 (0.2); AI/GH, −1.0 (0.1) (P = .06). Absolute height change was: AI, +18.2 (1.6) cm; GH, +20.6 (1.5) cm; AI/GH, +22.5 (1.4) cm (P = .01) (expected height gain at −2.0 height SDS, +13.0 cm). AI/GH had higher fat free mass accrual. Measures of bone health, safety labs, and adverse events were similar in all groups. Letrozole caused higher T and lower estradiol than anastrozole. Conclusions: Combination therapy with AI/GH increases height potential in pubertal boys with ISS more than GH and AI alone treated for 24–36 months with a strong safety profile. PMID:27710241

  3. Associations Among Quadriceps Strength and Rate of Torque Development 6 Weeks Post Anterior Cruciate Ligament Reconstruction and Future Hop and Vertical Jump Performance: A Prospective Cohort Study.

    PubMed

    Pua, Yong-Hao; Mentiplay, Benjamin F; Clark, Ross A; Ho, Jia-Ying

    2017-11-01

    Study Design Prospective cohort. Background Quadriceps strength is associated with hop distance and jump height in persons who have undergone anterior cruciate ligament (ACL) reconstruction. However, it is unknown whether the ability to rapidly generate quadriceps torque in the early phase of recovery is associated with future hopping and jumping performance in this population. Objective To evaluate the prospective associations among quadriceps strength and rate of torque development (RTD) and single-leg hop for distance, vertical jump height, vertical ground reaction force (vGRF), and vertical force loading rate during a landing task in persons who have undergone ACL reconstruction. Methods Seventy patients with unilateral ACL reconstruction participated. At 6 weeks post ACL reconstruction, isometric quadriceps strength and RTD were measured using a dynamometer. At 6 months following ACL reconstruction, patients performed the single-leg hop for distance test. Patients also performed the single-leg vertical jump test on a force plate that measured maximum jump height, vGRF, and average loading rate during landing. Results Both quadriceps strength and RTD at 6 weeks post ACL reconstruction were associated with all hopping and jumping measures at 6 months post ACL reconstruction (P≤.04). Single-leg hop distance was associated more closely with quadriceps strength than with quadriceps RTD (P = .05), and vertical jump height and vGRF measures were associated more closely with quadriceps RTD than with quadriceps strength (P = .05 and P<.01, respectively). Both quadriceps measures were associated with loading rate. Conclusion Quadriceps strength and RTD are complementary but distinct predictors of future hopping and jumping performance in persons who have undergone ACL reconstruction. These findings may contribute to improved rehabilitation of patients who are at risk for poor jumping/hopping performance and abnormal knee loading. J Orthop Sports Phys Ther 2017;47(11):845-852. Epub 13 Oct 2017. doi:10.2519/jospt.2017.7133.

  4. Fine-Scale Vertical Stratification and Guild Composition of Saproxylic Beetles in Lowland and Montane Forests: Similar Patterns despite Low Faunal Overlap

    PubMed Central

    Weiss, Matthias; Procházka, Jiří; Schlaghamerský, Jiří; Cizek, Lukas

    2016-01-01

    Objective The finer scale patterns of arthropod vertical stratification in forests are rarely studied and poorly understood. Further, there are no studies investigating whether and how altitude affects arthropod vertical stratification in temperate forests. We therefore investigated the fine-scale vertical stratification of diversity and guild structure of saproxylic beetles in temperate lowland and montane forests and compared the resulting patterns between the two habitats. Methods The beetles were sampled with flight intercept traps arranged into vertical transects (sampling heights 0.4, 1.2, 7, 14, and 21 m). A triplet of such transects was installed in each of the five sites in the lowland and in the mountains; 75 traps were used in each forest type. Results 381 species were collected in the lowlands and 236 species in the mountains. Only 105 species (21%) were found at both habitats; in the montane forest as well as in the lowlands, the species richness peaked at 1.2 m, and the change in assemblage composition was most rapid near the ground. The assemblages clearly differed between the understorey (0.4 m, 1.2 m) and the canopy (7 m, 14 m, 21 m) and between the two sampling heights within the understorey, but less within the canopy. The stratification was better pronounced in the lowland, where canopy assemblages were richer than those near the forest floor (0.4 m). In the mountains the samples from 14 and 21 m were more species poor than those from the lower heights. The guild structure was similar in both habitats. Conclusions The main patterns of vertical stratification and guild composition were strikingly similar between the montane and the lowland forest despite the low overlap of their faunas. The assemblages of saproxylic beetles were most stratified near ground. The comparisons of species richness between canopy and understorey may thus give contrasting results depending on the exact sampling height in the understorey. PMID:26978783

  5. Lower incisor dentoalveolar compensation and symphysis dimensions among Class I and III malocclusion patients with different facial vertical skeletal patterns.

    PubMed

    Molina-Berlanga, Núria; Llopis-Perez, Jaume; Flores-Mir, Carlos; Puigdollers, Andreu

    2013-11-01

    To compare lower incisor dentoalveolar compensation and mandible symphysis morphology among Class I and Class III malocclusion patients with different facial vertical skeletal patterns. Lower incisor extrusion and inclination, as well as buccal (LA) and lingual (LP) cortex depth, and mandibular symphysis height (LH) were measured in 107 lateral cephalometric x-rays of adult patients without prior orthodontic treatment. In addition, malocclusion type (Class I or III) and facial vertical skeletal pattern were considered. Through a principal component analysis (PCA) related variables were reduced. Simple regression equation and multivariate analyses of variance were also used. Incisor mandibular plane angle (P < .001) and extrusion (P  =  .03) values showed significant differences between the sagittal malocclusion groups. Variations in the mandibular plane have a negative correlation with LA (Class I P  =  .03 and Class III P  =  .01) and a positive correlation with LH (Class I P  =  .01 and Class III P  =  .02) in both groups. Within the Class III group, there was a negative correlation between the mandibular plane and LP (P  =  .02). PCA showed that the tendency toward a long face causes the symphysis to elongate and narrow. In Class III, alveolar narrowing is also found in normal faces. Vertical facial pattern is a significant factor in mandibular symphysis alveolar morphology and lower incisor positioning, both for Class I and Class III patients. Short-faced Class III patients have a widened alveolar bone. However, for long-faced and normal-faced Class III, natural compensation elongates the symphysis and influences lower incisor position.

  6. The use of cancellous block allograft for sinus floor augmentation with simultaneous implant placement in the posterior atrophic maxilla.

    PubMed

    Chaushu, Gavriel; Mardinger, Ofer; Calderon, Shlomo; Moses, Ofer; Nissan, Joseph

    2009-03-01

    The simultaneous placement of dental implants during sinus augmentation is advocated in cases in which >or=4 to 5 mm of alveolar bone exists coronally to the sinus floor. The aim of the present study was to assess the survival rate of dental implants placed during sinus augmentation and stabilized by the use of cancellous freeze-dried block allograft. Residual alveolar ridge height

  7. Deriving Surface NO2 Mixing Ratios from DISCOVER-AQ ACAM Observations: A Method to Assess Surface NO2 Spatial Variability

    NASA Astrophysics Data System (ADS)

    Silverman, M. L.; Szykman, J.; Chen, G.; Crawford, J. H.; Janz, S. J.; Kowalewski, M. G.; Lamsal, L. N.; Long, R.

    2015-12-01

    Studies have shown that satellite NO2 columns are closely related to ground level NO2 concentrations, particularly over polluted areas. This provides a means to assess surface level NO2 spatial variability over a broader area than what can be monitored from ground stations. The characterization of surface level NO2 variability is important to understand air quality in urban areas, emissions, health impacts, photochemistry, and to evaluate the performance of chemical transport models. Using data from the NASA DISCOVER-AQ campaign in Baltimore/Washington we calculate NO2 mixing ratios from the Airborne Compact Atmospheric Mapper (ACAM), through four different methods to derive surface concentration from column measurements. High spectral resolution lidar (HSRL) mixed layer heights, vertical P3B profiles, and CMAQ vertical profiles are used to scale ACAM vertical column densities. The derived NO2 mixing ratios are compared to EPA ground measurements taken at Padonia and Edgewood. We find similar results from scaling with HSRL mixed layer heights and normalized P3B vertical profiles. The HSRL mixed layer heights are then used to scale ACAM vertical column densities across the DISCOVER-AQ flight pattern to assess spatial variability of NO2 over the area. This work will help define the measurement requirements for future satellite instruments.

  8. Hydraulic Fracture Growth in a Layered Formation based on Fracturing Experiments and Discrete Element Modeling

    NASA Astrophysics Data System (ADS)

    Yushi, Zou; Xinfang, Ma; Tong, Zhou; Ning, Li; Ming, Chen; Sihai, Li; Yinuo, Zhang; Han, Li

    2017-09-01

    Hydraulic fracture (HF) height containment tends to occur in layered formations, and it significantly influences the entire HF geometry or the stimulated reservoir volume. This study aims to explore the influence of preexisting bedding planes (BPs) on the HF height growth in layered formations. Laboratory fracturing experiments were performed to confirm the occurrence of HF height containment in natural shale that contains multiple weak and high-permeability BPs under triaxial stresses. Numerical simulations were then conducted to further illustrate the manner in which vertical stress, BP permeability, BP density(or spacing), pump rate, and fluid viscosity control HF height growth using a 3D discrete element method-based fracturing model. In this model, the rock matrix was considered transversely isotropic and multiple BPs can be explicitly represented. Experimental and numerical results show that the vertically growing HF tends to be limited by multi-high-permeability BPs, even under higher vertical stress. When the vertically growing HF intersects with the multi-high-permeability BPs, the injection pressure will be sharply reduced. If a low pumping rate or a low-viscosity fluid is used, the excess fracturing fluid leak-off into the BPs obviously decreases the rate of pressure build up, which will then limit the growth of HF. Otherwise, a higher pumping rate and/or a higher viscosity will reduce the leak-off time and fluid volume, but increase the injection pressure to drive the HF to grow and to penetrate through the BPs.

  9. 49 CFR 572.6 - Head.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... nose when the midsagittal plane is vertical. (2) Drop the head from the specified height by means that... drawings subtended by number SA 150 M010. (b) When the head is dropped from a height of 10 inches in...

  10. 49 CFR 572.32 - Head.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... midsagittal plane is vertical. EC01AU91.162 (4) Drop the head from the specified height by means that ensure... dropped from a height of 14.8 inches in accordance with paragraph (c) of this section, the peak resultant...

  11. 49 CFR 572.32 - Head.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... midsagittal plane is vertical. EC01AU91.162 (4) Drop the head from the specified height by means that ensure... dropped from a height of 14.8 inches in accordance with paragraph (c) of this section, the peak resultant...

  12. 49 CFR 572.6 - Head.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... nose when the midsagittal plane is vertical. (2) Drop the head from the specified height by means that... drawings subtended by number SA 150 M010. (b) When the head is dropped from a height of 10 inches in...

  13. 49 CFR 572.6 - Head.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... nose when the midsagittal plane is vertical. (2) Drop the head from the specified height by means that... drawings subtended by number SA 150 M010. (b) When the head is dropped from a height of 10 inches in...

  14. Influence of maxillary posterior discrepancy on upper molar vertical position and facial vertical dimensions in subjects with or without skeletal open bite

    PubMed Central

    Aliaga-Del Castillo, Aron; Pérez-Vargas, Luis Fernando; Flores-Mir, Carlos

    2016-01-01

    Summary Objectives: To determine the influence of maxillary posterior discrepancy on upper molar vertical position and dentofacial vertical dimensions in individuals with or without skeletal open bite (SOB). Materials and methods: Pre-treatment lateral cephalograms of 139 young adults were examined. The sample was divided into eight groups categorized according to their sagittal and vertical skeletal facial growth pattern and maxillary posterior discrepancy (present or absent). Upper molar vertical position, overbite, lower anterior facial height and facial height ratio were measured. Independent t-test was performed to determine differences between the groups considering maxillary posterior discrepancy. Principal component analysis and MANCOVA test were also used. Results: No statistically significant differences were found comparing the molar vertical position according to maxillary posterior discrepancy for the SOB Class I group or the group with adequate overbite. Significant differences were found in SOB Class II and Class III groups. In addition, an increased molar vertical position was found in the group without posterior discrepancy. Limitations: Some variables closely related with the individual’s intrinsic craniofacial development that could influence the evaluated vertical measurements were not considered. Conclusions and implications: Overall maxillary posterior discrepancy does not appear to have a clear impact on upper molar vertical position or facial vertical dimensions. Only the SOB Class III group without posterior discrepancy had a significant increased upper molar vertical position. PMID:26385786

  15. Influence of maxillary posterior discrepancy on upper molar vertical position and facial vertical dimensions in subjects with or without skeletal open bite.

    PubMed

    Arriola-Guillén, Luis Ernesto; Aliaga-Del Castillo, Aron; Pérez-Vargas, Luis Fernando; Flores-Mir, Carlos

    2016-06-01

    To determine the influence of maxillary posterior discrepancy on upper molar vertical position and dentofacial vertical dimensions in individuals with or without skeletal open bite (SOB). Pre-treatment lateral cephalograms of 139 young adults were examined. The sample was divided into eight groups categorized according to their sagittal and vertical skeletal facial growth pattern and maxillary posterior discrepancy (present or absent). Upper molar vertical position, overbite, lower anterior facial height and facial height ratio were measured. Independent t-test was performed to determine differences between the groups considering maxillary posterior discrepancy. Principal component analysis and MANCOVA test were also used. No statistically significant differences were found comparing the molar vertical position according to maxillary posterior discrepancy for the SOB Class I group or the group with adequate overbite. Significant differences were found in SOB Class II and Class III groups. In addition, an increased molar vertical position was found in the group without posterior discrepancy. Some variables closely related with the individual's intrinsic craniofacial development that could influence the evaluated vertical measurements were not considered. Overall maxillary posterior discrepancy does not appear to have a clear impact on upper molar vertical position or facial vertical dimensions. Only the SOB Class III group without posterior discrepancy had a significant increased upper molar vertical position. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  16. Presurgical cleft lip anthropometrics and dental arch relationships in patients with complete unilateral cleft lip and palate.

    PubMed

    Antonarakis, Gregory S; Adibfar, Alex; Tompson, Bryan D; Paedo, D; Daskalogiannakis, John; Fisher, David M

    2015-05-01

    To investigate associations between anthropometric lip measurements and dental arch relationships in patients with complete unilateral cleft lip and palate (CUCLP). Retrospective cross-sectional study. Children with CUCLP. Anthropometric lip measurements, made immediately prior to lip repair, were available for each patient. The dental arch relationships were evaluated on dental study casts (8.6 ± 0.9 years) taken prior to any orthodontic treatment and prior to alveolar bone graft, using the modified Huddart and Bodenham (MHB) scoring system. The presence of associations between anthropometric lip measurements and dental arch relationships was determined using linear regression analysis. In the 63 patients included in the study, the cleft lateral lip element was deficient in height in 87% and in transverse width in 86% of patients. Patients with more deficient cleft-side lateral lip height were more likely to present with more negative MHB scores (r = .443; P < .001). Conversely, patients with more deficient cleft-side lateral lip transverse width more often presented with more positive MHB scores (r = .281; P = .025). In patients with CUCLP, there is a wide variability in the degree of deficiency of the cleft-side lateral lip element, both in the vertical and in the transverse dimension. The extent of this deficiency may, in part, predict the resulting dental arch relationships.

  17. Quantitative evaluation of bone development of the distal phalanx of the cow hind limb using computed tomography.

    PubMed

    Tsuka, T; Ooshita, K; Sugiyama, A; Osaki, T; Okamoto, Y; Minami, S; Imagawa, T

    2012-01-01

    Computed tomography (CT) was performed on 400 claws (200 inner and 200 outer claws) of 100 pairs of bovine hind limbs to investigate the etiological theory that an exacerbating factor for ulceration is exostosis of the tuberculum flexorium within the distal phalanx. A variety of morphological changes of the tuberculum flexorium of bovine hind limb claws was visualized by 3-dimensional CT, and the geometry of these claws suggested a growth pattern of bone development with respect to the assumed daily loading patterns. This growth occurs initially at the abaxial caudal aspect of the distal phalanx and is followed by horizontal progression toward the axial aspect. The length of downward bone development on the solar face of the distal phalanx was 2.73±1.32 mm in the outer claws, significantly greater than in the inner claws (2.38±0.96 mm). Ratios of downward (vertical) bone development to the thickness of the subcutis and the corium (VerBD ratios) did not differ between the outer and inner claws (36.7 vs. 38.3%, respectively). Ratios of horizontal bone development to the axial-to-abaxial line of the tuberculum flexorium (HorBD ratios) were approximately 60% for both outer and inner claws. These quantitative measures regarding horizontal and vertical bone development within the distal phalanx were positively correlated with age and VerBD ratios (r=0.53 and r=0.36 for the inner and outer claws, respectively). Correlations between claw width of the outer claw and length of vertical bone development (r=0.43), the HorBD ratio (r=0.51), and the VerBD ratio (r=0.42) suggested that the relative size difference between the inner and outer claws enhances bone development in the outer claw. Correlation coefficients between VerBD and HorBD ratios (r=0.52 and 0.63 for the inner and outer claws, respectively) suggested that horizontal and vertical bone development occurs as a synchronized process within the tuberculum flexorium. This age-related progress of bone development within the tuberculum flexorium is associated with increased exposure to several exacerbating factors and the laminitic process. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Three-dimensional Numerical Analysis on Blade Response of Vertical Axis Tidal Current Turbine Under Operational Condition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Ye; Karri, Naveen K.; Wang, Qi

    Tidal power as a large-scale renewable source of energy has been receiving significant attention recently because of its advantages over the wind and other renewal energy sources. The technology used to harvest energy from tidal current is called a tidal current turbine. Though some of the principles of wind turbine design are applicable to tidal current turbines, the design of latter ones need additional considerations like cavitation damage, corrosion etc. for the long-term reliability of such turbines. Depending up on the orientation of axis, tidal current turbines can be classified as vertical axis turbines or horizontal axis turbines. Existing studiesmore » on the vertical axis tidal current turbine focus more on the hydrodynamic aspects of the turbine rather than the structural aspects. This paper summarizes our recent efforts to study the integrated hydrodynamic and structural aspects of the vertical axis tidal current turbines. After reviewing existing methods in modeling tidal current turbines, we developed a hybrid approach that combines discrete vortex method -finite element method that can simulate the integrated hydrodynamic and structural response of a vertical axis turbine. This hybrid method was initially employed to analyze a typical three-blade vertical axis turbine. The power coefficient was used to evaluate the hydrodynamic performance, and critical deflection was considered to evaluate the structural reliability. A sensitivity analysis was also conducted with various turbine height-to-radius ratios. The results indicate that both the power output and failure probability increase with the turbine height, suggesting a necessity for optimal design. An attempt to optimize a 3-blade vertical axis turbine design with hybrid method yielded a ratio of turbine height to radius (H/R) about 3.0 for reliable maximum power output.« less

  19. CGVD2013: The Geoid-based Vertical Datum in Canada

    NASA Astrophysics Data System (ADS)

    Robin, C. M. I.; Veronneau, M.; Huang, J.

    2016-12-01

    In November 2013, Canada established the Canadian Geodetic Vertical Datum of 2013 (CGVD2013). This new datum is defined by an equipotential surface (Wo =62,636,856 m2/s2) and realized by a geoid model (CGG2013), making it compatible with Global Navigation Satellite Systems (GNSS) for positioning. The adoption of CGVD2013 represents a major shift from the old vertical datum (CGVD28), which was defined by the mean sea level at selected tide gauges and propagated in land by precise levelling measurements. This new vertical datum represents also a major impact for the users, who have relied on the access to benchmarks for the last 100 years to conduct their surveys. The presentation will not only discuss the advantages for Canada to moving to a geoid-based datum, but also discuss the challenges in maintaining such as vertical datum in a period where technology is moving rapidly and data are coming in large numbers allowing the possibility of a quick turnaround in the release of new realisations of the geoid-based vertical datum. This is quite different as when benchmarks were re-surveyed at a 20- to 30-year cycle or sometime never revisited again, resulting in heights that were very consistent over many years (even though benchmarks are moving up and down). The question is how to fulfil users who want to live in a static world as much as possible, but simultaneously updating the vertical datum to assure utmost accuracy for scientific and technological requirements. Consequently, the presentation will give a look at the future American height system, as the US National Geodetic Survey is in the process of updating by 2022 the geometric and height reference systems, being NAD 83 and NAVD 88, respectively.

  20. Physical Determinants of Interval Sprint Times in Youth Soccer Players

    PubMed Central

    Amonette, William E.; Brown, Denham; Dupler, Terry L.; Xu, Junhai; Tufano, James J.; De Witt, John K.

    2014-01-01

    Relationships between sprinting speed, body mass, and vertical jump kinetics were assessed in 243 male soccer athletes ranging from 10–19 years. Participants ran a maximal 36.6 meter sprint; times at 9.1 (10 y) and 36.6 m (40 y) were determined using an electronic timing system. Body mass was measured by means of an electronic scale and body composition using a 3-site skinfold measurement completed by a skilled technician. Countermovement vertical jumps were performed on a force platform - from this test peak force was measured and peak power and vertical jump height were calculated. It was determined that age (r=−0.59; p<0.01), body mass (r=−0.52; p<0.01), lean mass (r=−0.61; p<0.01), vertical jump height (r=−0.67; p<0.01), peak power (r=−0.64; p<0.01), and peak force (r=−0.56; p<0.01) were correlated with time at 9.1 meters. Time-to-complete a 36.6 meter sprint was correlated with age (r=−0.71; p<0.01), body mass (r=−0.67; p<0.01), lean mass (r=−0.76; p<0.01), vertical jump height (r=−0.75; p<0.01), peak power (r=−0.78; p<0.01), and peak force (r=−0.69; p<0.01). These data indicate that soccer coaches desiring to improve speed in their athletes should devote substantive time to fitness programs that increase lean body mass and vertical force as well as power generating capabilities of their athletes. Additionally, vertical jump testing, with or without a force platform, may be a useful tool to screen soccer athletes for speed potential. PMID:25031679

  1. Countermovement depth - a variable which clarifies the relationship between the maximum power output and height of a vertical jump.

    PubMed

    Gajewski, Jan; Michalski, Radosław; Buśko, Krzysztof; Mazur-Różycka, Joanna; Staniak, Zbigniew

    2018-01-01

    The aim of this study was to identify the determinants of peak power achieved during vertical jumps in order to clarify relationship between the height of jump and the ability to exert maximum power. One hundred young (16.8±1.8 years) sportsmen participated in the study (body height 1.861 ± 0.109 m, body weight 80.3 ± 9.2 kg). Each participant performed three jump tests: countermovement jump (CMJ), akimbo countermovement jump (ACMJ), and spike jump (SPJ). A force plate was used to measure ground reaction force and to determine peak power output. The following explanatory variables were included in the model: jump height, body mass, and the lowering of the centre of mass before launch (countermovement depth). A model was created using multiple regression analysis and allometric scaling. The model was used to calculate the expected power value for each participant, which correlated strongly with real values. The value of the coefficient of determination R2 equalled 0.89, 0.90 and 0.98, respectively, for the CMJ, ACMJ, and SPJ jumps. The countermovement depth proved to be a variable strongly affecting the maximum power of jump. If the countermovement depth remains constant, the relative peak power is a simple function of jump height. The results suggest that the jump height of an individual is an exact indicator of their ability to produce maximum power. The presented model has a potential to be utilized under field condition for estimating the maximum power output of vertical jumps.

  2. Increased cortical area and thickness in the distal radius in subjects with SHOX-gene mutation.

    PubMed

    Frederiksen, A L; Hansen, S; Brixen, K; Frost, M

    2014-12-01

    Short-stature homeobox (SHOX) gene haploinsufficiency may cause skeletal dysplasia including Léri-Weill Dyschondrosteosis (LWD), a clinical entity characterised by the triad of low height, mesomelic disproportion and Madelung's deformity of the wrist. Bone microarchitecture and estimated strength in adult SHOX mutation carriers have not been examined. Twenty-two subjects with a SHOX mutation including 7 males and 15 females with a median age of 38.8 [21.1-52.2] years were recruited from five unrelated families. The control group consisted of 22 healthy subjects matched on age and sex. Bone mineral density (BMD) was measured by dual-energy X-ray absorptiometry. Bone geometry, volumetric density, microarchitecture and finite element estimated (FEA) bone strength were measured using high-resolution peripheral quantitative computed tomography (HR-pQCT). A full region of interest (ROI) image analysis and height-matched ROI analyses adjusting for differences in body height between the two groups were performed. Areal BMD and T-scores showed no significant differences between cases and controls. Total radius area was smaller in cases than controls (207 [176-263] vs. 273 [226-298] mm, p<0.01). Radius cortical bone area (74 ± 20 vs. 58 ± 17 mm(2), p=0.01) and thickness (1.16 ± 0.30 vs. 0.84 ± 0.26 mm, p<0.01) as well as total density (428 ± 99 vs. 328 ± 72 mg/cm(3), p<0.01) were higher in SHOX mutation carriers compared to controls. Radius trabecular bone area (119 [103-192] vs. 202 [168-247] mm(2), p<0.01) and trabecular number (1.61 [1.46-2.07] vs. 1.89 [1.73-2.08] mm(-1), p=0.01) were smaller in SHOX mutation carriers. Tibia trabecular thickness was lower in cases (0.067 ± 0.012 vs. 0.076 ± 0.012 mm, p=0.01). These results remained significant after adjustment for differences in body height and when restricting analyses to females. There were no differences in BMD, radius and tibia cortical porosity or FEA failure load between groups. A segment of cortical bone defect was identified in the distal radius adjacent to ulna in five unrelated SHOX mutation carriers. Subjects with a SHOX mutation presented with a different bone geometry in radius and tibia while there were no differences in BMD or failure load compared to controls, suggesting that mutations in SHOX gene may have an impact on bone microarchitecture albeit not bone strength. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. The effects of treatment combining an agonist of gonadotropin-releasing hormone with growth hormone in pubertal patients with isolated growth hormone deficiency.

    PubMed

    Toublanc, J E; Couprie, C; Garnier, P; Job, J C

    1989-06-01

    The final height of patients treated with growth hormone for isolated growth hormone deficiency has, up to now, been subnormal, with a mean below -2 SD in the series reported, an insufficient height at the onset of puberty and a more or less accelerated bone maturation during puberty being two important factors of the poor results. A long-acting analogue of gonadoliberin, Trp6-GnRH, has been given to GH-treated patients with isolated growth hormone deficiency at the time they reached pubertal stage 2, in combination with unchanged doses of GH, for one year in 11 and for two years in 7 of them. It resulted in an increase in the height age/bone age ratio and a reduction of the height insufficiency for bone age. The increase was slight but significant after one year, and fair after two years, in spite of reduced annual growth rate. Post-analogue follow-up in 5 patients with continued GH treatment showed a good development of growth and of puberty. It is concluded that combination of the long-acting Trp6-GnRH analogue and GH for 1-2 years in patients with isolated growth hormone deficiency whose puberty starts with a very insufficient height may be an appropriate way to improve their growth parameters. Studies with increased doses of GH or increased frequency of injections could help to optimize the results. Several years of follow-up are needed for demonstrating the results on final height.

  4. Analysis of Hyoid-Larynx Complex Using 3D Geometric Morphometrics.

    PubMed

    Loth, Anthony; Corny, Julien; Santini, Laure; Dahan, Laurie; Dessi, Patrick; Adalian, Pascal; Fakhry, Nicolas

    2015-06-01

    The aim of this study was to obtain a quantitative anatomical description of the hyoid bone-larynx complex using modern 3D reconstruction tools. The study was conducted on 104 bones from CT scan images of living adult subjects. Three-dimensional reconstructions were created from CT scan images using AVIZO 6.2 software package. A study of this complex was carried out using metric and morphological analyses. Characteristics of the hyoid bone and larynx were highly heterogeneous and were closely linked with the sex, height, and weight of the individuals. Height and width of larynx were significantly greater in men than in women (24.99 vs. 17.3 mm, p ≤ 0.05 and 46.75 vs. 41.07, p ≤ 0.05), whereas the thyroid angle was larger in females (81.12° vs. 74.48°, p ≤ 0.05). There was a significant correlation between the height and weight of subjects and different measurements of the hyoid-larynx complex. (Pearson's coefficient correlation r = 0.42, p ≤ 0.05 between the height of thyroid ala and the height of subjects and r = 0.1, p ≤ 0.05 between the height of thyroid ala and the weight of subjects). Shape and size analysis of the hyoid-larynx complex showed the existence of a significant sexual dimorphism and high interindividual heterogeneity depending to patient morphology. These results encourage us to go further with functional and imaging correlations.

  5. Over height impact avoidance and incident detection system : research project capsule.

    DOT National Transportation Integrated Search

    2016-07-01

    During the construction and repair of bridges, work platforms or construction-related : containment may result in restricted vertical clearances at a work : location. Some tractor-trailer combinations are prone to over-height collisions : at these lo...

  6. The Geoscience Laser Altimeter System (GLAS) for the ICESAT Mission

    NASA Technical Reports Server (NTRS)

    Abshire, James B.; Sun, Xia-Li; Ketchum, Eleanor A.; Afzal, Robert S.; Millar, Pamela S.; Smith, David E. (Technical Monitor)

    2000-01-01

    The Laser In space Technology Experiment, Shuttle Laser Altimeter and the Mars Observer Laser Altimeter have demonstrated accurate measurements of atmospheric backscatter and Surface heights from space. The recent MOLA measurements of the Mars surface have 40 cm vertical resolution and have reduced the global uncertainty in Mars topography from a few km to about 5 m. The Geoscience Laser Altimeter System (GLAS) is a next generation lidar for Earth orbit being developed as part of NASA's Icesat Mission. The GLAS design combines a 10 cm precision surface lidar with a sensitive dual wavelength cloud and aerosol lidar. GLAS will precisely measure the heights of the Earth's polar ice sheets, establish a grid of accurate height profiles of the Earth's land topography, and profile the vertical backscatter of clouds and aerosols on a global scale. GLAS is being developed to fly on a small dedicated spacecraft in a polar orbit with a 590 630 km altitude at inclination of 94 degrees. GLAS is scheduled to launch in the summer 2001 and to operate continuously for a minimum of 3 years with a goal of 5 years. The primary mission for GLAS is to measure the seasonal and annual changes in the heights of the Greenland and Antarctic ice sheets. GLAS will continuously measure the vertical distance from orbit to the Earth's surface with 1064 nm pulses from a ND:YAG laser at a 40 Hz rate. Each 5 nsec wide laser pulse is used to produce a single range measurement, and the laser spots have 66 m diameter and about 170 m center-center spacings. When over land GLAS will profile the heights of the topography and vegetation. The GLAS receiver uses a 1 m diameter telescope and a Si APD detector. The detector signal is sampled by an all digital receiver which records each surface echo waveform with I nsec resolution and a stored echo record lengths of either 200, 400, or 600 samples. Analysis of the echo waveforms within the instrument permits discrimination between cloud and surface echoes. Ground based echo analysis permits precise ranging, determining the roughness or slopes of the surface as well as the vertical distributions of vegetation illuminated by the laser. Accurate knowledge of the laser beam's pointing angle is needed to prevent height biases when over sloped surfaces. For surfaces with 2 deg. slopes, knowledge of pointing angle of the beam's centroid to about 8 urad is needed to achieve 10 cm height accuracy. GLAS uses a stellar reference system (SRS) to determine the pointing angle of each laser firing relative to inertial space. The SRS uses a high precision star camera oriented toward local zenith and a gyroscope to determine the inertial orientation of the SRS optical bench. The far field pattern of each laser is measured pulse relative to the star camera with a laser reference system (LRS). Optically measuring each laser far field pattern relative to the orientation of the star camera and gyroscope permits the precise pointing angle of each laser pulse to be determined. GLAS will also determine the vertical distributions of clouds and aerosols by measuring the vertical profile of laser energy backscattered by the atmosphere at both 1064 and 532 nm. The 1064 nm measurements use the Si APD detector and profile the height and vertical structure of thicker clouds. The measurements at 532 nm use new highly sensitive photon counting, detectors, and measure the height distributions of very thin Clouds and aerosol layers. With averaging these can be used to determine the height of the planetary boundary layer. The instrument design and expected performance will be discussed.

  7. 33 CFR 84.03 - Vertical positioning and spacing of lights.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Vertical positioning and spacing... Vertical positioning and spacing of lights. (a) On a power-driven vessel of 20 meters or more in length the... is carried, then that light, at a height above the hull of not less than 5 meters, and, if the...

  8. 33 CFR 84.03 - Vertical positioning and spacing of lights.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Vertical positioning and spacing... Vertical positioning and spacing of lights. (a) On a power-driven vessel of 20 meters or more in length the... is carried, then that light, at a height above the hull of not less than 5 meters, and, if the...

  9. 33 CFR 84.03 - Vertical positioning and spacing of lights.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Vertical positioning and spacing... Vertical positioning and spacing of lights. (a) On a power-driven vessel of 20 meters or more in length the... is carried, then that light, at a height above the hull of not less than 5 meters, and, if the...

  10. 33 CFR 84.03 - Vertical positioning and spacing of lights.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Vertical positioning and spacing... Vertical positioning and spacing of lights. (a) On a power-driven vessel of 20 meters or more in length the... is carried, then that light, at a height above the hull of not less than 5 meters, and, if the...

  11. Biomechanical and Performance Differences Between Female Soccer Athletes in National Collegiate Athletic Association Divisions I and III

    PubMed Central

    Smith, Rose; Ford, Kevin R; Myer, Gregory D; Holleran, Adam; Treadway, Erin; Hewett, Timothy E

    2007-01-01

    Context: The recent increase in women's varsity soccer participation has been accompanied by a lower extremity injury rate that is 2 to 6 times that of their male counterparts. Objective: To define the differences between lower extremity biomechanics (knee abduction and knee flexion measures) and performance (maximal vertical jump height) between National Collegiate Athletic Association Division I and III female soccer athletes during a drop vertical jump. Design: Mixed 2 × 2 design. Setting: Research laboratory. Patients or Other Participants: Thirty-four female collegiate soccer players (Division I: n = 19; Division III: n = 15) participated in the study. The groups were similar in height and mass. Intervention(s): Each subject performed a maximal vertical jump, followed by 3 drop vertical jumps. Main Outcome Measure(s): Kinematics (knee abduction and flexion angles) and kinetics (knee abduction and flexion moments) were measured with a motion analysis system and 2 force platforms during the drop vertical jumps. Results: Knee abduction angular range of motion and knee abduction external moments were not different between groups (P > .05). However, Division I athletes demonstrated decreased knee flexion range of motion (P = .038) and greater peak external knee flexion moment (P = .009) compared with Division III athletes. Division I athletes demonstrated increased vertical jump height compared with Division III (P = .008). Conclusions: Division I athletes demonstrated different sagittal-plane mechanics than Division III athletes, which may facilitate improved performance. The similarities in anterior cruciate ligament injury risk factors (knee abduction torques and angles) may correlate with the consistent incidence of anterior cruciate ligament injury across divisions. PMID:18174935

  12. Biomechanical considerations for distraction of the monobloc, Le Fort III, and Le Fort I segments.

    PubMed

    Figueroa, Alvaro A; Polley, John W; Figueroa, Aaron D

    2010-09-01

    Distraction osteogenesis is effective for correction of severe maxillary and midface hypoplasia. The vectors controlling the segment to be moved must be planned. This requires knowledge of the physical characteristics of the osteotomized bone segment, including the location of the center of mass (free body) and the center of resistance (restrained body). The purpose of this study was to determine the center of mass of the osteotomized monobloc, Le Fort III, and Le Fort I bone segments. A dry human skull was used to sequentially isolate three bone segments: monobloc, Le Fort III, and Le Fort I. Each segment was suspended from three different points, and digital photographs were obtained from each suspension. The photographs were digitally superimposed. The center of mass was determined by calculating the intersection of the suspension lines. The center of mass for the monobloc segment was located at a point 43.5 percent of the total height from the occlusal plane to the superior edge of the frontal bone supraorbital osteotomy. For the Le Fort III, it was located 38 percent of the total height from the occlusal plane to the superior edge of the osteotomized base of the nasal bones. For the Le Fort I, it was 53 percent of the total height from the occlusal plane to the superior edge of the osteotomized maxillary bone. Knowledge of the location of the center of mass in the monobloc, Le Fort III, and Le Fort I segments provides a starting point for the clinician when planning vectors for advancement with distraction.

  13. A 3-year clinical and radiographic study of implants placed simultaneously with maxillary sinus floor augmentations using a new nanocrystalline hydroxyapatite.

    PubMed

    Heinemann, F; Mundt, T; Biffar, R; Gedrange, T; Goetz, W

    2009-12-01

    The aims of this case series was to evaluate the success rate of implants and their restorations, the sinus bone graft resorption, and the marginal bone loss around the implants when nanocristalline HA embedded in a silica matrix was exclusively used as grafting material. In 13 partially edentulous patients of a private practice having missing teeth in the posterior maxilla and a subantral bone height between 3 and 7 mm, 19 sinus augmentations (100% Nanobone, Artoss, Rostock, Germany) by the lateral lift technique were performed. The implants (Tiolox/Tiologic Implants, Dentaurum, Ispringen, Germany) were simultaneously placed. After 6 to 9 months 37 implants were restored with fixed dental prostheses. The clinical evaluation included peri-implant parameters, periotest measurements and the restorations. The radiographic bone heights over time were estimated with linear mixed models. The implant success rate was 100% after three years. The periotest values (between -7 and -6) after implant abutment connection indicated a solid osseointegration. The mean rates of the marginal bone loss over the first year were higher (mesial: -0.55, distal: -0.51 mm) than the annual rates thereafter (mesial: -0.09 mm, distal: -0.08 mm). The mean rates of changes in the total bone height were neglectable (<0.2 mm) and not significant. The prosthodontic and esthetic evaluation revealed a successful outcome. Within the limits of this clinical report it may be concluded that maxillary sinus augmentation using 100% nanocristalline HA embedded in a silica matrix to support implants is a reliable procedure.

  14. 78 FR 18846 - Certifications and Exemptions Under the International Regulations for Preventing Collisions at...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-28

    ... vertical separation of the anchor lights and vertical placement of the forward anchor light above the hull... forward of height light to visibility; visibility; visibility; sides in stern in above hull forward rule...

  15. Oviposition and vertical dispersal of Aedes mosquitoes in multiple storey buildings in Colombo district, Sri Lanka.

    PubMed

    Jayathilake, T A Hasini D G; Wickramasinghe, Mervyn B; de Silva, B G D Nissanka K

    2015-09-01

    The Colombo City in Sri Lanka is experiencing tremendous development and construction of multiple storey buildings and high rise apartments. The change in housing types and microhabitats might have altered the flight and breeding behaviour of Aedes mosquito population. This study was carried out to determine the vertical dispersal and abundance of Aedes mosquitoes in multiple storey buildings in the Colombo district, with respect to abiotic factors such as rainfall, humidity and wind speed. Hence, this study is of paramount importance, particularly for planning and implementation of control measures against Aedes mosquitoes. An ovitrap based study was carried out at four selected multiple storey buildings in four residential areas located in Colombo, Sri Lanka, from August to December 2013. Results were analyzed using four indices; ovitrap index, mean number of larvae, mean number of eggs and mean number of larvae per ovipaddle. The results implied that Aedes mosquitoes could be found in different elevations from ground floor to the highest floor (130 ft). There was a significant difference between height and ovitrap index (p<0.05), and height and mean number of larvae per recovered ovipaddle (p<0.05). The highest index value for mean number of eggs was observed as 3.492 ± 0.655 at the 6th floor (60 ft high from ground level). At the same height (60 ft height) other indices (ovitrap index, mean number of larvae and mean number of larvae per ovipaddle) also displayed higher values, i.e. 13.19 ± 2.98%, 1.366 ± 0.527, and 2.070 ± 0.421%, respectively. Abiotic factors such as wind speed, coastal nature, etc. displayed a significant effect to the vertical dispersal of Aedes mosquitoes (p<0.05). The study suggested that Aedes mosquitoes are able to breed at any level of the buildings and not restricted by their height. The indices (mean number of larvae, mean number of eggs) representing the vertical dispersal with respect to abundance seemed to be statistically non-significant (p>0.05) with height which indicates high abundance of Aedes mosquitoes at higher floors. Abiotic factors also seemed to cause significant effect to the vertical dispersal of Aedes mosquitoes in high rise buildings.

  16. Spaceborne Potential for Examining Taiga-Tundra Ecotone Form and Vulnerability

    NASA Technical Reports Server (NTRS)

    Montesano, Paul M.; Sun, Guoqing; Dubayah, Ralph O.; Ranson, K. Jon

    2016-01-01

    In the taiga-tundra ecotone (TTE), site-dependent forest structure characteristics can influence the subtle and heterogeneous structural changes that occur across the broad circumpolar extent. Such changes may be related to ecotone form, described by the horizontal and vertical patterns of forest structure (e.g., tree cover, density and height) within TTE forest patches, driven by local site conditions, and linked to ecotone dynamics. The unique circumstance of subtle, variable and widespread vegetation change warrants the application of spaceborne data including high-resolution (less than 5m) spaceborne imagery (HRSI) across broad scales for examining TTE form and predicting dynamics. This study analyzes forest structure at the patch-scale in the TTE to provide a means to examine both vertical and horizontal components of ecotone form. We demonstrate the potential of spaceborne data for integrating forest height and density to assess TTE form at the scale of forest patches across the circumpolar biome by (1) mapping forest patches in study sites along the TTE in northern Siberia with a multi-resolution suite of spaceborne data, and (2) examining the uncertainty of forest patch height from this suite of data across sites of primarily diffuse TTE forms. Results demonstrate the opportunities for improving patch-scale spaceborne estimates of forest height, the vertical component of TTE form, with HRSI. The distribution of relative maximum height uncertainty based on prediction intervals is centered at approximately 40%, constraining the use of height for discerning differences in forest patches. We discuss this uncertainty in light of a conceptual model of general ecotone forms, and highlight how the uncertainty of spaceborne estimates of height can contribute to the uncertainty in identifying TTE forms. A focus on reducing the uncertainty of height estimates in forest patches may improve depiction of TTE form, which may help explain variable forest responses in the TTE to climate change and the vulnerability of portions of the TTE to forest structure change. structural changes.

  17. Spaceborne potential for examining taiga-tundra ecotone form and vulnerability

    NASA Astrophysics Data System (ADS)

    Montesano, Paul M.; Sun, Guoqing; Dubayah, Ralph O.; Ranson, K. Jon

    2016-07-01

    In the taiga-tundra ecotone (TTE), site-dependent forest structure characteristics can influence the subtle and heterogeneous structural changes that occur across the broad circumpolar extent. Such changes may be related to ecotone form, described by the horizontal and vertical patterns of forest structure (e.g., tree cover, density, and height) within TTE forest patches, driven by local site conditions, and linked to ecotone dynamics. The unique circumstance of subtle, variable, and widespread vegetation change warrants the application of spaceborne data including high-resolution (< 5 m) spaceborne imagery (HRSI) across broad scales for examining TTE form and predicting dynamics. This study analyzes forest structure at the patch scale in the TTE to provide a means to examine both vertical and horizontal components of ecotone form. We demonstrate the potential of spaceborne data for integrating forest height and density to assess TTE form at the scale of forest patches across the circumpolar biome by (1) mapping forest patches in study sites along the TTE in northern Siberia with a multi-resolution suite of spaceborne data and (2) examining the uncertainty of forest patch height from this suite of data across sites of primarily diffuse TTE forms. Results demonstrate the opportunities for improving patch-scale spaceborne estimates of forest height, the vertical component of TTE form, with HRSI. The distribution of relative maximum height uncertainty based on prediction intervals is centered at ˜ 40 %, constraining the use of height for discerning differences in forest patches. We discuss this uncertainty in light of a conceptual model of general ecotone forms and highlight how the uncertainty of spaceborne estimates of height can contribute to the uncertainty in identifying TTE forms. A focus on reducing the uncertainty of height estimates in forest patches may improve depiction of TTE form, which may help explain variable forest responses in the TTE to climate change and the vulnerability of portions of the TTE to forest structure change.

  18. Preoperative Radiographic and CT Findings Predicting Syndesmotic Injuries in Supination-External Rotation-Type Ankle Fractures.

    PubMed

    Choi, Young; Kwon, Soon-Sun; Chung, Chin Youb; Park, Moon Seok; Lee, Seung Yeol; Lee, Kyoung Min

    2014-07-16

    The Lauge-Hansen classification system does not provide sufficient data related to syndesmotic injuries in supination-external rotation (SER)-type ankle fractures. The aim of the present study was to investigate factors helpful for the preoperative detection of syndesmotic injuries in SER-type ankle fractures using radiographs and computed tomography (CT). A cohort of 191 consecutive patients (104 male and eighty-seven female patients with a mean age [and standard deviation] of 50.7 ± 16.4 years) with SER-type ankle fractures who had undergone operative treatment were included. Preoperative ankle radiographs and CT imaging scans were made for all patients, and clinical data, including age, sex, and mechanism of injury (high or low-energy trauma), were collected. Patients were divided into two groups: the stable syndesmotic group and the unstable syndesmotic group, with a positive intraoperative lateral stress test leading to syndesmotic screw fixation. Fracture height, fracture length, medial joint space, extent of fracture, and bone attenuation were measured on radiographs and CT images and were compared between the groups. Binary logistic regression analysis was performed to identify the factors that significantly contributed to unstable syndesmotic injuries. Receiver operating characteristic curves were calculated, and cutoff values were suggested to predict unstable syndesmotic injuries on preoperative imaging measurements. Of the 191 patents with a SER-type ankle fracture, thirty-eight (19.9%) had a concurrent unstable syndesmotic injury. Age, sex, mechanism of injury, fracture height, medial joint space, and bone attenuation were significantly different between the two groups. In the binary logistic analysis, fracture height, medial joint space, and bone attenuation were found to be significant factors contributing to unstable syndesmotic injuries. The cutoff values for predicting unstable syndesmotic injuries were a fracture height of >3 mm and a medial joint space of >4.9 mm on CT scans, and a fracture height of >7 mm and medial joint space of >4.5 mm on radiographs. Fracture height, medial joint space, and bone attenuation were useful factors for the preoperative detection of unstable syndesmotic injuries in SER-type ankle fractures. Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  19. Temperature and Relative Humidity Vertical Profiles within Planetary Boundary Layer in Winter Urban Airshed

    NASA Astrophysics Data System (ADS)

    Bendl, Jan; Hovorka, Jan

    2017-12-01

    The planetary boundary layer is a dynamic system with turbulent flow where horizontal and vertical air mixing depends mainly on the weather conditions and geomorphology. Normally, air temperature from the Earth surface decreases with height but inversion situation may occur, mainly during winter. Pollutant dispersion is poor during inversions so air pollutant concentration can quickly rise, especially in urban closed valleys. Air pollution was evaluated by WHO as a human carcinogen (mostly by polycyclic aromatic hydrocarbons) and health effects are obvious. Knowledge about inversion layer height is important for estimation of the pollution impact and it can give us also information about the air pollution sources. Temperature and relative humidity vertical profiles complement ground measurements. Ground measurements were conducted to characterize comprehensively urban airshed in Svermov, residential district of the city of Kladno, about 30 km NW of Prague, from the 2nd Feb. to the 3rd of March 2016. The Svermov is an air pollution hot-spot for long time benzo[a]pyrene (B[a]P) limit exceedances, reaching the highest B[a]P annual concentration in Bohemia - west part of the Czech Republic. Since the Svermov sits in a shallow valley, frequent vertical temperature inversion in winter and low emission heights of pollution sources prevent pollutant dispersal off the valley. Such orography is common to numerous small settlements in the Czech Republic. Ground measurements at the sports field in the Svermov were complemented by temperature and humidity vertical profiles acquired by a Vaisala radiosonde positioned at tethered He-filled balloon. Total number of 53 series of vertical profiles up to the height of 300 m was conducted. Meteorology parameters were acquired with 4 Hz frequency. The measurements confirmed frequent early-morning and night formation of temperature inversion within boundary layer up to the height of 50 m. This rather shallow inversion had significant influence on air quality due to inversion cap over the valley. Nevertheless, formation of an inversion showed strong diurnal variability. For example, on the 18th Feb. early morning shallow inversion quickly disappeared within less than 2 hours. According to this study tethered balloon measurements has proved to be a good tool for completion comprehensive ground air quality measurements.

  20. Proximal half angle of the screw thread is a critical design variable affecting the pull-out strength of cancellous bone screws.

    PubMed

    Wang, Yingxu; Mori, Ryuji; Ozoe, Nobuaki; Nakai, Takahisa; Uchio, Yuji

    2009-11-01

    Screws with strong pull-out strength have been sought for the treatment of cancellous bone. We hypothesized that an obliquely angled screw thread has advantages over conventional vertical thread with a minimal proximal half angle. Metal and bone screws were made of stainless steel and porcine cortical bone. Their proximal half angle was set at 0 degrees , 30 degrees , or 60 degrees . The screws were inserted into porcine cancellous bone. At 0 degrees , the thread faced the recipient bone vertically. Pullout tests at a rate of 30 mm/min (n=40, each screw type) and microcomputed tomography (n=6) were conducted. The pull-out strength of the screws was maximal at 30 degrees ; 348.8 (SD, 44.1)N with metal and 326.6 (39.4)N with bone. It was intermediate at 0 degrees ; 301.9 (35.9)N with metal and 278.2 (30.6)N with bone. It was minimal at 60 degrees; 126.5 (39.0)N with metal and 174.8 (29.7)N with bone. Cancellous bone was damaged between the threads at 30 degrees , while intact cancellous bone was preserved between the threads at 0 degrees. A proximal half angle of around 30 degrees is appropriate because the pullout force is applied to the recipient bone evenly. Commercial cancellous screws can be improved by changing the thread shape to minimize the damage to recipient bone.

  1. Reconstruction of the maxilla following hemimaxillectomy defects with scapular tip grafts and dental implants.

    PubMed

    Mertens, Christian; Freudlsperger, Christian; Bodem, Jens; Engel, Michael; Hoffmann, Jürgen; Freier, Kolja

    2016-11-01

    Treatment of post-resective defects of the maxilla can be challenging and usually requires dental obturation or microvascular reconstruction. As compared to soft-tissue microvascular grafts, bone reconstruction can additionally allow for facial support and retention of dental implants. The aim of this study was to evaluate scapular tip grafts with respect to their applicability for maxillary reconstruction and their potential to retain dental implants for later dental rehabilitation. In this retrospective study, 14 patients with hemimaxillectomy defects were reconstructed with free scapular tip grafts, oriented horizontally, to rebuild the palate and alveolar ridge. After bone healing, three-dimensional virtual implant planning was performed, and a radiographic guide was fabricated to enable implant placement in the optimal anatomic and prosthetic position. All patients' mastication and speech were evaluated, along with the extent of defect closure, suitability of the graft sites for implant placement, and soft-tissue stability. Pre- and postsurgical radiographs were also evaluated. A good postoperative outcome was achieved in all patients, with complete closure of maxillary defects that were class II, according to the system of Brown and Shaw. Additional bone augmentation was necessary in two patients in order to increase vertical bone height. Patients were subsequently treated with 50 dental implants to retain dental prostheses. In all cases, additional soft-tissue surgery was necessary to achieve a long-term stable periimplant situation. No implants were lost during the mean observation period of 34 months. Due to its specific form, the scapular tip graft is well suited to reconstruct the palate and maxillary alveolar ridge and to enable subsequent implant-retained rehabilitation. Due to the limited bone volume, an accurate three-dimensional graft orientation is essential. Furthermore, most cases require additional soft-tissue surgery to achieve a long-term stable periimplant situation. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Hypohydration reduces vertical ground reaction impulse but not jump height.

    PubMed

    Cheuvront, Samuel N; Kenefick, Robert W; Ely, Brett R; Harman, Everett A; Castellani, John W; Frykman, Peter N; Nindl, Bradley C; Sawka, Michael N

    2010-08-01

    This study examined vertical jump performance using a force platform and weighted vest to determine why hypohydration (approximately 4% body mass) does not improve jump height. Measures of functional performance from a force platform were determined for 15 healthy and active males when euhydrated (EUH), hypohydrated (HYP) and hypohydrated while wearing a weighted vest (HYP(v)) adjusted to precisely match water mass losses. HYP produced a significant loss of body mass [-3.2 +/- 0.5 kg (-3.8 +/- 0.6%); P < 0.05], but body mass in HYP(v) was not different from EUH. There were no differences in absolute or relative peak force or power among trials. Jump height was not different between EUH (0.380 +/- 0.048 m) and HYP (0.384 +/- 0.050 m), but was 4% lower (P < 0.05) in HYP(v) (0.365 +/- 0.52 m) than EUH due to a lower jump velocity between HYP(v) and EUH only (P < 0.05). However, vertical ground reaction impulse (VGRI) was reduced in both HYP and HYP(v) (2-3%) compared with EUH (P < 0.05). In conclusion, this study demonstrates the failure to improve jump height when HYP can be explained by offsetting reductions in both VGRI and body mass.

  3. [Tibio-Calcaneal Arthrodesis with Vertically Placed Tricortical Bone Graft after Traumatic Talar Extrusion - a Case Report].

    PubMed

    Popelka, V; Zamborský, R

    2017-01-01

    The aim of this publication is to present a case report of a 38-year-old patient with traumatic astragalectomy and resultant foot reconstruction surgery using a combination of talus compensation by vertically placed tricortical autograft and pantalar arthrodesis with a retrograde calcaneotibial nail (hindfoot nail). The advantage of this treatment is based on a solid, stable osteosynthesis, while maintaining the length of the limb. Key words: traumatic talar extrusion, tibiocalcaneal arthrodesis, hindfoot nail, bone graft, pantalar arthrodesis.

  4. HiMeter: Telling You the Height Rather than the Altitude.

    PubMed

    Ye, Haibo; Dong, Kai; Gu, Tao

    2018-05-25

    The altitude of a moving user is important context information for mobile technologies and applications. However, with the increasing pervasiveness of smartphones and abundant mobile applications, developers and users have gradually discovered that the height is more useful than altitude in many situations. The height is often a relative value, which is the vertical distance to the ground rather than the vertical distance to sea level, and we believe that it is useful in many applications, such as localization/navigation, sport/health and tourism/travel. In this paper, we first carried out a nation-wide online survey to confirm the desirability for the height information in mobile applications, and the result is positive. Then, we proposed HiMeter, an effective and accurate approach to calculating the height of the smartphone. HiMeter makes use of a low-power barometer on the smartphone and does not require GPS or back-server support. We concentrate on the vertical moving pattern of the user and designed several novel techniques, resulting in HiMeter not needing any reference points, and the complex process of calculating the absolute altitude can be avoided. The field studies show that HiMeter can achieve an accuracy of within 5 m in 90% of cases indoors and an accuracy of 10 m in 83% of cases outdoors. Compared to the existing works, HiMeter is more accurate and practical and is more suitable for usage in many mobile applications.

  5. Coherence of simulated atmospheric boundary-layer turbulence

    NASA Astrophysics Data System (ADS)

    Jiadong, Zeng; Zhiguo, Li; Mingshui, Li

    2017-12-01

    The coherences in a plane perpendicular to incoming flow are measured in wind tunnel simulations of atmospheric turbulent flow. The measured coherences are compared with analytical expressions tailored to field measurements and with theoretical coherence models which assume homogeneous turbulence and the von Kármán’s spectrum. The comparison indicates that the simulated atmospheric boundary layer flow is approximately horizontally homogeneous turbulence. Based on the above assumption and the systematic analysis of lateral coherence, it can be concluded that the lateral coherences of simulated atmospheric boundary turbulence can be determined accurately using the von Kármán spectrum and the turbulence parameters measured by a few measurement points. The measured results also show that the spatial characteristics of vertical coherences are closely related to the dimensionless parameter {{Δ }}z/({\\bar{z}}0.3{L}ux 0.7). The vertical coherence at two heights can be roughly estimated by the ratio to {{Δ }}z/({\\bar{z}}0.3{L}ux 0.7). The relationship between the phase angles of u-, v- and w-components and the vertical separation distance and the height from the ground is further analyzed. Finally, the roles of the type of land surface roughness, the height from the ground, the turbulence intensity and the integral length scale in lateral and vertical coherences are also discussed in this study.

  6. A Procedure for Calculating the Vertical Space Height of the Sacrum When Determining Skeletal Height for Use in the Anatomical Method of Adult Stature Estimation.

    PubMed

    Hayashi, Atsuko; Emanovsky, Paul D; Pietrusewsky, Michael; Holland, Thomas D

    2016-03-01

    Estimating stature from skeletonized remains is one of the essential parameters in the development of a biological profile. A new procedure for determining skeletal height (SKH) incorporating the vertical space height (VSH) from the anterior margin of the sacral promontory to the superior margins of the acetabulae for use in the anatomical method of stature estimation is introduced. Regression equations for stature estimation were generated from measurements of 38 American males of European ancestry from the William M. Bass Donated Skeletal Collection. The modification to the procedure results in a SKH that is highly correlated with stature (r = 0.925-0.948). Stature estimates have low standard errors of the estimate ranging from 21.79 to 25.95 mm, biases from to 0.50 to 0.94 mm, and accuracy rates from 17.71 mm to 19.45 mm. The procedure for determining the VSH, which replaces "S1 height" in traditional anatomical method models, is a key improvement to the method. © 2016 American Academy of Forensic Sciences.

  7. Analysis of polymorphisms of the vitamin D receptor, estrogen receptor, and collagen Ialpha1 genes and their relationship with height in children with bone cancer.

    PubMed

    Ruza, Elena; Sotillo, Elena; Sierrasesúmaga, Luis; Azcona, Cristina; Patiño-García, Ana

    2003-10-01

    The authors' objectives were to compare height at diagnosis of children with bone tumors with that of Spanish reference children; to analyze the frequency of the genotypes for the polymorphisms of the vitamin D receptor (VDR), estrogen receptor (ER), and collagen Ialpha1 (COLIalpha1) genes in patients and in healthy controls; and to test the relationship between the genetic markers and height. Height and weight at diagnosis were measured in 58 osteosarcoma and 36 Ewing sarcoma patients and compared with standards published for Spanish reference children according to sex and age. For the molecular analysis, genetic polymorphisms of the VDR (Fok I, Apa I, and TaqI), ER (Pvu II and XbaI), and COLIalpha1 (Msc I) genes were characterized in 72 osteosarcoma and 53 Ewing sarcomas and in a group of 143 healthy matched children. Osteosarcoma and Ewing sarcoma patients were significantly taller than Spanish reference children. Osteosarcoma patients showed a significantly higher frequency of the Ff genotype for the Fok I polymorphism (VDR gene) than the control group. The odds ratio for this genotype was 1.78, with an increased relative risk of 78% for heterozygous Ff carriers. Among Ewing sarcoma patients, this same genotype was significantly associated with lower height than homozygotes (FF or ff). Children with bone cancer are significantly taller than the reference population, which may be influenced by the genotype for the Fok I polymorphism of the VDR gene.

  8. Implant Supported Distal Extension over Denture Retained by Two Types of Attachments. A Comparative Radiographic Study by Cone Beam Computed Tomography

    PubMed Central

    Mahrous, Ahmed I; Aldawash, Hussien A; Soliman, Tarek A; Banasr, Fahad H; Abdelwahed, Ahmed

    2015-01-01

    Background: This study was conducted to compare and evaluate the effect of two different attachments (locator attachment and ball and socket [B&S] attachment) on implants and natural abutments supporting structures, in cases of limited inter-arch spaces in mandibular Kennedy Class I implant supported removable partial over dentures by measuring the bone height changes through the cone beam radiographic technology. Materials and Methods: Two implants were positioned in the first or second molar area following the two-stage surgical protocol. Two equal groups were divided ten for each: Group I: Sides were the placed implants restored by the locator attachment. Group II: The other sides, implants were restored by B&S attachment. Evaluation of the implants and main abutments supporting structures of each group was done at the time of removable partial over denture insertion, 6, 12 and 18 months by measuring the bone height changes using cone beam computed tomography. Results: Implants with locator attachment showed marginal bone height better effects on implants and main abutments supporting structures. Conclusion: Implants restored by locator attachment shows better effects on bone of both main natural abutments and implant than those restored with ball and socket. PMID:26028894

  9. Efficacy of a bioactive glass-ceramic (Biosilicate) in the maintenance of alveolar ridges and in osseointegration of titanium implants.

    PubMed

    Roriz, Virgílio M; Rosa, Adalberto L; Peitl, Oscar; Zanotto, Edgar D; Panzeri, Heitor; de Oliveira, Paulo T

    2010-02-01

    The aims of this research were to evaluate the efficacy of a bioactive glass-ceramic (Biosilicate) and a bioactive glass (Biogran) placed in dental sockets in the maintenance of alveolar ridge and in the osseointegration of Ti implants. Six dogs had their low premolars extracted and the sockets were implanted with Biosilicate, Biogran particles, or left untreated. After the extractions, measurements of width and height on the alveolar ridge were taken. After 12 weeks a new surgery was performed to take the final ridge measurements and to insert bilaterally three Ti implants in biomaterial-implanted and control sites. Eight weeks post-Ti implant placement block biopsies were processed for histological and histomorphometric analysis. The percentages of bone-implant contact (BIC), of mineralized bone area between threads (BABT), and of mineralized bone area within the mirror area (BAMA) were determined. The presence of Biosilicate or Biogran particles preserved alveolar ridge height without affecting its width. No significant differences in terms of BIC, BAMA, and BABT values were detected among Biosilicate, Biogran, and the non-implanted group. The results of the present study indicate that filling of sockets with either Biosilicate or Biogran particles preserves alveolar bone ridge height and allows osseointegration of Ti implants.

  10. Flow tilt angle measurements using lidar anemometry

    NASA Astrophysics Data System (ADS)

    Dellwik, Ebba; Mann, Jakob

    2010-05-01

    A new way of estimating near-surface mean flow tilt angles from ground based Doppler lidar measurements is presented. The results are compared with traditional mast based in-situ sonic anemometry. The tilt angle assessed with the lidar is based on 10 or 30 minute mean values of the velocity field from a conically scanning lidar. In this mode of measurement, the lidar beam is rotated in a circle by a prism with a fixed angle to the vertical at varying focus distances. By fitting a trigonometric function to the scans, the mean vertical velocity can be estimated. Lidar measurements from (1) a fetch-limited beech forest site taken at 48-175m above ground level, (2) a reference site in flat agricultural terrain and (3) a second reference site in very complex terrain are presented. The method to derive flow tilt angles and mean vertical velocities from lidar has several advantages compared to sonic anemometry; there is no flow distortion caused by the instrument itself, there are no temperature effects and the instrument misalignment can be corrected for by comparing tilt estimates at various heights. Contrary to mast-based instruments, the lidar measures the wind field with the exact same alignment error at a multitude of heights. Disadvantages with estimating vertical velocities from a lidar compared to mast-based measurements are slightly increased levels of statistical errors due to limited sampling time, because the sampling is disjunct and a requirement for homogeneous flow. The estimated mean vertical velocity is biased if the flow over the scanned circle is not homogeneous. However, the error on the mean vertical velocity due to flow inhomogeneity can be approximated by a function of the angle of the lidar beam to the vertical, the measurement height and the vertical gradient of the mean vertical velocity, whereas the error due to flow inhomogeneity on the horizontal mean wind speed is independent of the lidar beam angle. For the presented measurements over forest, it is evaluated that the systematic error due to the inhomogeneity of the flow is less than 0.2 degrees. Other possibilities for utilizing lidars for flow tilt angle and mean vertical velocities are discussed.

  11. Maxillary sinus floor augmentation using a beta-tricalcium phosphate (Cerasorb) alone compared to autogenous bone grafts.

    PubMed

    Zijderveld, Steven A; Zerbo, Ilara R; van den Bergh, Johan P A; Schulten, Engelbert A J M; ten Bruggenkate, Chris M

    2005-01-01

    A prospective human clinical study was conducted to determine the clinical and histologic bone formation ability of 2 graft materials, a beta-tricalcium phosphate (Cerasorb; Curasan, Kleinostheim, Germany) and autogenous chin bone, in maxillary sinus floor elevation surgery. Ten healthy patients underwent a bilateral (n = 6) or unilateral (n = 4) maxillary sinus floor elevation procedure under local anesthesia. In each case, residual posterior maxillary bone height was between 4 and 8 mm. In cases of bilateral sinus floor elevation, the original bone was augmented with a split-mouth design with 100% beta-tricalcium phosphate on the test side and 100% chin bone on the contralateral control side. The unilateral cases were augmented with 100% beta-tricalcium phosphate. After a healing period of 6 months, ITI full body screw-type implants (Straumann, Waldenburg, Switzerland) were placed. At the time of implant surgery, biopsy samples were removed with a 3.5-mm trephine drill. Sixteen sinus floor elevations were performed. Forty-one implants were placed, 26 on the test side and 15 on the control side. The clinical characteristics at the time of implantation differed, especially regarding clinical appearance and drilling resistance. The increase in height was examined radiographically prior to implantation and was found to be sufficient in all cases. After a mean of nearly 1 year of follow-up, no implant losses or failures had occurred. The promising clinical results of the present study and the lack of implant failures are probably mainly the result of requiring an original bone height of at least 4 mm at the implant location. Although autogenous bone grafting is still the gold standard, according to the clinical results, the preimplantation sinus floor elevation procedure used, which involved a limited volume of beta-tricalcium phosphate, appeared to be a clinically reliable procedure in this patient population.

  12. Evaluation of the Surface Treatment on Bone Healing in a Transmucosal 1-mm Area of Implant Abutment: An Experimental Study in the Rabbit Tibia.

    PubMed

    Gehrke, Sergio Alexandre; da Silva Neto, Ulisses Tavares

    2016-06-01

    The objective of the present study was to investigate the effect on bone tissue healing patterns in 1-mm area treated in the transmucosal surface of the abutment in the tibia of rabbits. Forty-six abutments were divided into two groups: control group (CG) with 14 abutments with smooth surface and experimental group (EG) with 32 abutments presenting a 1-mm area of the transmucosal surface treated through sandblasting with microparticles of titanium oxide followed by acid etching. Five samples of each group were analyzed using an optical laser profilometer for surface roughness characterization. Thirty-six Morse taper implants (3.5 mm in diameter and 7 mm in length) were inserted 1.5 mm subcrestal into the tibiae of nine rabbits. The implants were removed after 8, 10, and 12 weeks for histological analysis. The histological slides were prepared and analyzed qualitatively in relation to the new bone at the interface bone-abutment and quantitatively, in relation to bone height from the base of the implant. These data were computed and statistically compared inside the groups using analysis of variance and the U-test between groups for same time. Both groups exhibited bone growth in the direction and over the surface of the abutments, with good healing. However, the EG group showed an increased height of bone formation in the crestal direction, and highly significant differences were observed (p < .001) between these measured values. Under the limitations of the present study, histological follow-up at 8, 10, and 12 weeks showed that transmucosal 1-mm area of implant abutment with treatment of the surface facilitated the maintenance of bone height around the abutment compared with the same abutment with the totally smooth surface. © 2015 Wiley Periodicals, Inc.

  13. Theoretical axial wall angulation for rotational resistance form in an experimental-fixed partial denture

    PubMed Central

    2017-01-01

    PURPOSE The aim of this study was to determine the influence of long base lengths of a fixed partial denture (FPD) to rotational resistance with variation of vertical wall angulation. MATERIALS AND METHODS Trigonometric calculations were done to determine the maximum wall angle needed to resist rotational displacement of an experimental-FPD model in 2-dimensional plane. The maximum wall angle calculation determines the greatest taper that resists rotation. Two different axes of rotation were used to test this model with five vertical abutment heights of 3-, 3.5-, 4-, 4.5-, and 5-mm. The two rotational axes were located on the mesial-side of the anterior abutment and the distal-side of the posterior abutment. Rotation of the FPD around the anterior axis was counter-clockwise, Posterior-Anterior (P-A) and clockwise, Anterior-Posterior (A-P) around the distal axis in the sagittal plane. RESULTS Low levels of vertical wall taper, ≤ 10-degrees, were needed to resist rotational displacement in all wall height categories; 2–to–6–degrees is generally considered ideal, with 7–to–10–degrees as favorable to the long axis of the abutment. Rotation around both axes demonstrated that two axial walls of the FPD resisted rotational displacement in each direction. In addition, uneven abutment height combinations required the lowest wall angulations to achieve resistance in this study. CONCLUSION The vertical height and angulation of FPD abutments, two rotational axes, and the long base lengths all play a role in FPD resistance form. PMID:28874995

  14. Validity of two methods for estimation of vertical jump height.

    PubMed

    Dias, Jonathan Ache; Dal Pupo, Juliano; Reis, Diogo C; Borges, Lucas; Santos, Saray G; Moro, Antônio R P; Borges, Noé G

    2011-07-01

    The objectives of this study were (a) to determine the concurrent validity of the flight time (FT) and double integration of vertical reaction force (DIF) methods in the estimation of vertical jump height with the video method (VID) as reference; (b) to verify the degree of agreement among the 3 methods; (c) to propose regression equations to predict the jump height using the FT and DIF. Twenty healthy male and female nonathlete college students participated in this study. The experiment involved positioning a contact mat (CTM) on the force platform (FP), with a video camera 3 m from the FP and perpendicular to the sagittal plane of the subject being assessed. Each participant performed 15 countermovement jumps with 60-second intervals between the trials. Significant differences were found between the jump height obtained by VID and the results with FT (p ≤ 0.01) and DIF (p ≤ 0.01), showing that the methods are not valid. Additionally, the DIF showed a greater degree of agreement with the reference method than the FT did, and both presented a systematic error. From the linear regression test was determined the prediction equations with a high degree of linearity between the methods VID vs. DIF (R = 0.988) and VID vs. FT (R = 0.979). Therefore, the prediction equations suggested may allow coaches to measure the vertical jump performance of athletes by the FT and DIF, using a CTM or an FP, which represents more practical and viable approaches in the sports field; comparisons can then be made with the results of other athletes evaluated by VID.

  15. Comparing preseason frontal and sagittal plane plyometric programs on vertical jump height in high-school basketball players.

    PubMed

    King, Jeffrey A; Cipriani, Daniel J

    2010-08-01

    The primary purpose of this study was to evaluate whether frontal plane (FP) plyometrics, which are defined as plyometrics dominated with a lateral component, would produce similar increases in vertical jump height (VJH) compared to sagittal plane (SP) Plyometrics. Thirty-two junior varsity and varsity high-school basketball players participated in 6 weeks of plyometric training. Players participated in either FP or SP plyometrics for the entire study. Vertical jump height was measured on 3 occasions: preintervention (baseline), at week 3 of preparatory training, and at week 6 of training. Descriptive statistics were calculated for VJH. A 2-way analysis of variance (ANOVA) with repeated measures was used to test the difference in mean vertical jump scores using FP and SP training modalities. Results showed a significant effect over time for vertical jump (p < 0.001). Moreover, a significant time by protocol interaction was noted (p < 0.032). A 1-way ANOVA demonstrated that only the SP group demonstrated improvements over time, in VJH, p < 0.05. The FP group did not improve statistically. The data from this study suggest that FP plyometric training did not have a significant effect on VJH and significant improvement in VJH was seen in subjects participating in SP plyometrics thus reinforcing the specificity principle of training. However, coaches should implement both types of plyometrics because both training modalities can improve power and quickness among basketball players.

  16. Modulation of the electronic property of phosphorene by wrinkle and vertical electric field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Yan; Wei, Zhongming, E-mail: zmwei@semi.ac.cn; Li, Jingbo, E-mail: jbli@semi.ac.cn

    2015-09-14

    The electronic properties of wrinkled phosphorene and its response to charge injection and external vertical electric field have been studied using first-principles calculations. It is found that small-size wrinkle systems have lower energy than wrinkle-free monolayer, suggesting that free-standing phosphorene spontaneously forms small protrusion on its nanosheet. The ratio of wrinkle height to curvature radius increases with enlarging height, indicating a promotion of field enhancement factor. Furthermore, the injected charges mostly distribute at peak and valley. Direct-to-indirect band-gap transition has been found for zigzag wrinkle with height of 14.81 Å. The band gaps of wrinkled nanosheets decrease almost linearly with increasingmore » field, which is caused by charge separation of valence band maximum and conduction band minimum.« less

  17. Somatic maturation and the relationship between bone mineral variables and types of sports among adolescents: cross-sectional study.

    PubMed

    Agostinete, Ricardo Ribeiro; Ito, Igor Hideki; Kemper, Han; Pastre, Carlos Marcelo; Rodrigues-Júnior, Mário Antônio; Luiz-de-Marco, Rafael; Fernandes, Rômulo Araújo

    2017-01-01

    Peak height velocity (PHV) is an important maturational event during adolescence that affects skeleton size. The objective here was to compare bone variables in adolescents who practiced different types of sports, and to identify whether differences in bone variables attributed to sports practice were dependent on somatic maturation status. Cross-sectional study, São Paulo State University (UNESP). The study was composed of 93 adolescents (12 to 16.5 years old), divided into three groups: no-sport group (n = 42), soccer/basketball group (n = 26) and swimming group (n = 25). Bone mineral density and content were measured using dual-energy x-ray absorptiometry and somatic maturation was estimated through using peak height velocity. Data on training load were provided by the coaches. Adolescents whose PHV occurred at an older age presented higher bone mineral density in their upper limbs (P = 0.018). After adjustments for confounders, such as somatic maturation, the swimmers presented lower values for bone mineral density in their lower limbs, spine and whole body. Only the bone mineral density in the upper limbs was similar between the groups. There was a negative relationship between whole-body bone mineral content and the weekly training hours (β: -1563.967; 95% confidence interval, CI: -2916.484 to -211.450). The differences in bone variables attributed to sport practice occurred independently of maturation, while high training load in situations of hypogravity seemed to be related to lower bone mass in swimmers.

  18. [Clinical analysis and genetic diagnosis of short-limb inherited short stature diseases in children].

    PubMed

    Li, Fang; Ma, Hong-Wei; Song, Ying; Hu, Man; Ren, Shuang; Yu, Ya-Fen; Zhao, Gui-Jie

    2013-11-01

    To analyze the clinical manifestations, bone X-ray findings and genetic analysis results of three short-limb inherited short stature diseases: achondroplasia (ACH), hypochondroplasia (HCH) and pseudoachondroplasia (PSACH). The clinical manifestations, bone X-ray findings, and genetic analysis results of 10 children with genetically confirmed short-limb inherited short stature diseases, including 4 cases of ACH 3 cases of HCH, and 3 cases of PSACH, were analyzed. The 10 patients had a mean body height of -3.69±1.79 SD, a mean sitting height/standing height ratio of 0.65±0.03, and a mean finger spacing/body height ratio of 0.93±0.04. Four ACH cases and 3 PSACH cases showed typical bone X-ray findings; one HCH case showed a smaller sciatic notch, and another HCH case showed no widening of interpedicular distance. G380R mutation in FGFR3 gene was detected in 3 of 4 ACH cases, and Y278C mutation in the other ACH case, N540K mutation in FGFR3 gene was detected in 3 HCH cases, and heterozygous mutations in COMP gene were detected in 3 PSACH cases. Children with ACH and PSACH have severer short stature and skeletal deformities than children with HCH, who have mild, atypical clinical manifestations. Bone X-ray and genetic analysis are helpful for the diagnosis and differential diagnosis of the three diseases. The mutational hotspots in two genes are involved in the three diseases, which is conducive to clinical genetic diagnosis.

  19. Restoration of a vertical alveolar bone defect by orthodontic relocation of a mesially impacted mandibular first molar.

    PubMed

    Kim, Sung-Jin; Kim, Jin-Wook; Choi, Tae-Hyun; Lee, Kee-Joon

    2015-04-01

    An impacted mandibular first molar tends to cause serious bone defects of the adjacent teeth. When choosing between the 2 typical treatment options-extraction or orthodontic relocation of the impacted tooth-the decision should be based on assessment of the prognosis. A 22-year-old man with severe mesioangulation and impaction of the mandibular first molar and a related vertical bone defect on the distal side of the second premolar was treated with extraction of the second molar and orthodontic relocation of the first molar with a retromolar miniscrew. Comprehensive orthodontic treatment involving premolar extraction was conducted. Strategic extraction of the molar and adequate orthodontic movement helped to restore the bone structure on the affected side. This case report suggests the effectiveness of restoration of bone defects by using viable periodontal tissues around the impacted tooth for the longevity of the periodontium. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  20. Prevalence of low bone mass among adolescents with nontransfusion-dependent hemoglobin E/β-thalassemia and its relationship with anemia severity.

    PubMed

    Nakavachara, Pairunyar; Petchkul, Jaturat; Jeerawongpanich, Krittha; Kiattisakthavee, Pornpimol; Manpayak, Teerarat; Netsakulnee, Parichat; Chaichanwattanakul, Katharee; Pooliam, Julaporn; Srichairatanakool, Somdet; Viprakasit, Vip

    2018-01-01

    Low bone mass is common among adolescents with transfusion-dependent β-thalassemia despite adequate transfusion and iron chelation. However, there are few reports regarding bone mineral density (BMD) among adolescents with nontransfusion-dependent thalassemia (NTDT). Indeed, only BMD data in patients with nontransfusion-dependent (NTD) β-thalassemia intermedia have been reported. No previous study has investigated BMD among adolescents with NTD hemoglobin (Hb) E/β-thalassemia. To determine the prevalence of low bone mass among adolescents with NTD Hb E/β-thalassemia and factors relating to low bone mass. We investigated BMD of lumbar spine (L2-L4; BMDLS) and total body (BMDTB), as measured by dual-energy X-ray absorptiometry, in 22 adolescents (aged 13.2-20 years) with NTD Hb E/β-thalassemia. Low bone mass was found to be 18.2% and 22.7% at the lumbar spine (BMDLS Z-score adjusted for bone age and height age) and 13.6% and 9.1% at the total body (BMDTB Z-score adjusted for bone age and height age). Patients with mean Hb level <8 g/dl were more likely to have low bone mass (BMDLS and BMDTB Z-scores adjusted for bone age) compared to those with Hb level ≥ 8 g/dl. Mean Hb level correlated with BMDLS and BMDTB Z-scores adjusted for bone age. We demonstrated that a low Hb level was associated with low bone mass among adolescents with NTD Hb E/β-thalassemia. A significant proportion of low bone mass among these patients highlights the importance of appropriate management, including red cell transfusion, vitamin D and calcium supplementation for improved long-term bone health. © 2017 Wiley Periodicals, Inc.

  1. 47 CFR 73.186 - Establishment of effective field at one kilometer.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... radiation (not less than one wave length or 5 times the vertical height in the case of a single element, i.e... lieu of the required minimum physical heights of the antennas proper. Also, in other situations, it may...

  2. 47 CFR 73.186 - Establishment of effective field at one kilometer.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... radiation (not less than one wave length or 5 times the vertical height in the case of a single element, i.e... lieu of the required minimum physical heights of the antennas proper. Also, in other situations, it may...

  3. 47 CFR 73.186 - Establishment of effective field at one kilometer.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... radiation (not less than one wave length or 5 times the vertical height in the case of a single element, i.e... lieu of the required minimum physical heights of the antennas proper. Also, in other situations, it may...

  4. 47 CFR 73.186 - Establishment of effective field at one kilometer.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... radiation (not less than one wave length or 5 times the vertical height in the case of a single element, i.e... lieu of the required minimum physical heights of the antennas proper. Also, in other situations, it may...

  5. The consequences of pediatric renal transplantation on bone metabolism and growth.

    PubMed

    Bacchetta, Justine; Ranchin, Bruno; Demède, Delphine; Allard, Lise

    2013-10-01

    During childhood, growth retardation, decreased final height and renal osteodystrophy are common complications of chronic kidney disease (CKD). These problems remain present in patients undergoing renal transplantation, even though steroid-sparing strategies are more widely used. In this context, achieving normal height and growth in children after transplantation is a crucial issue for both quality of life and self-esteem. The aim of this review is to provide an overview of pathophysiology of CKD-mineral bone disorder (MBD) in children undergoing renal transplantation and to propose keypoints for its daily management. In adults, calcimimetics are effective for posttransplant hyperparathyroidism, but data are missing in the pediatric population. Fibroblast growth factor 23 levels are associated with increased risk of rejection, but the underlying mechanisms remain unclear. A recent meta-analysis also demonstrated the effectiveness of rhGH therapy in short transplanted children. In 2013, the daily clinical management of CKD-MBD in transplanted children should still focus on simple objectives: to optimize renal function, to develop and promote steroid-sparing strategies, to provide optimal nutritional support to maximize final height and avoid bone deformations, to equilibrate calcium/phosphate metabolism so as to provide acceptable bone quality and cardiovascular status, to correct all metabolic and clinical abnormalities that can worsen both bone and growth (mainly metabolic acidosis, anemia and malnutrition), promote good lifestyle habits (adequate calcium intake, regular physical activity, no sodas consumption, no tobacco exposure) and eventually to correct native vitamin D deficiency (target of 25-vitamin D >75 nmol/l).

  6. Human Studies of Vertical and Horizontal Alveolar Ridge Augmentation Comparing Different Types of Bone Graft Materials: A Systematic Review.

    PubMed

    Chavda, Suraj; Levin, Liran

    2018-02-01

    Alveolar ridge augmentation can be completed with various types of bone augmentation materials (autogenous, allograft, xenograft, and alloplast). Currently, autogenous bone is labeled as the "gold standard" because of faster healing times and integration between native and foreign bone. No systematic review has currently determined whether there is a difference in implant success between various bone augmentation materials. The purpose of this article was to systematically review comparative human studies of vertical and horizontal alveolar ridge augmentation comparing different types of bone graft materials (autogenous, allograft, xenograft, and alloplast). A MEDLINE search was conducted under the 3 search concepts of bone augmentation, dental implants, and alveolar ridge augmentation. Studies pertaining to socket grafts or sinus lifts were excluded. Case reports, small case series, and review papers were excluded. A bias assessment tool was applied to the final articles. Overall, 219 articles resulted from the initial search, and 9 articles were included for final analysis. There were no discernible differences in implant success between bone augmentation materials. Generally, patients preferred nonautogenous bone sources as there were fewer hospital days, less pain, and better recovery time. Two articles had industrial support; however, conclusions of whether that support influenced the outcomes could not be determined. Future comparative studies should compare nonautogenous bone sources and have longer follow-up times.

  7. Measurement of earth pressures on concrete box culverts under highway embankments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, M.Z.; Drumm, E.C.; Bennett, R.M.

    1999-07-01

    To obtain a better understanding of the stresses acting on cast-in-place concrete box culverts, and to investigate the conditions which resulted in a culvert failure under about 12 meters of backfill, two sections of a new culvert were instrumented. The measured earth pressure distribution was found to depend upon the height of the embankment over the culvert. For low embankment heights (less than one-half the culvert width), the average measured vertical earth pressures, weighted by tributary length, were about 30% greater than the recommended AASHTO pressures. The measured lateral pressures were slightly greater than the AASHTO pressures. As the embankmentmore » height increased, the measured weighted average vertical stress exceeded the AASHTO pressures by about 20%. Lateral pressures which exceeded the vertical pressures were recorded at the bottom of the culvert walls, and small lateral pressures were recorded on the upper locations of the wall. The high lateral pressures at the base of the wall are consistent with the results from finite element analyses with high density (modulus) backfill material placed around the culvert.« less

  8. Effect of interfacial composition on Ag-based Ohmic contact of GaN-based vertical light emitting diodes

    NASA Astrophysics Data System (ADS)

    Wu, Ning; Xiong, Zhihua; Qin, Zhenzhen

    2018-02-01

    By investigating the effect of a defective interface structure on Ag-based Ohmic contact of GaN-based vertical light-emitting diodes, we found a direct relationship between the interfacial composition and the Schottky barrier height of the Ag(111)/GaN(0001) interface. It was demonstrated that the Schottky barrier height of a defect-free Ag(111)/GaN(0001) interface was 2.221 eV, and it would be dramatically decreased to 0.375 eV with the introduction of one Ni atom and one Ga vacancy at the interface structure. It was found that the tunability of the Schottky barrier height can be attributed to charge accumulations around the interfacial defective regions and an unpinning of the Fermi level, which explains the experimental phenomenon of Ni-assisted annealing improving the p-type Ohmic contact characteristic. Lastly, we propose a new method of using Cu as an assisted metal to realize a novel Ag-based Ohmic contact. These results provide a guideline for the fabrication of high-quality Ag-based Ohmic contact of GaN-based vertical light-emitting diodes.

  9. [The effect of osteogenic inducer on healing of tooth extraction sockets].

    PubMed

    Chen, Junliang; Shan, Chuncheng; He, Yun; Xia, Delin

    2012-06-01

    To study the effect of osteogenic inducer (dexamethasone, beta-sodium glycerophosphate and Vitamin C) carried by gelatin sponge on healing and remodeling of tooth extraction sockets. Fifty rabbits were selected. After extracting the first premolars of bilateral maxillary, the right side tooth extraction sockets were filled with gelatin sponge containing osteogenic inducer as experimental side, tooth extraction sockets on left side were filled with gelatin sponge as control. Every ten rabbits were executed at the end of 1, 2, 4, 8, 12 weeks after tooth extraction. Bone density was measured through digital X-ray images. The specimens were examined by histology. The absorption height of alveolar bone at 12 weeks was measured. X-ray measurement showed that the bone density of experimental side was higher than that of control side at 2, 4, 8, 12 weeks, the difference had statistical significance (P<0.01). The histology examination showed that new bone formation in tooth extraction sockets of experimental side was earlier than that in control side. The absorptional height of alveolar bone had significant difference between experimental side and control side (P<0.01), of which experimental side was less. Filling the osteogenic inducer in tooth extraction sockets can promote the healing and new bone formation and prevent from alveolar bone absorption.

  10. Beethoven's last piano sonata and those who follow crocodiles: cross-domain mappings of auditory pitch in a musical context.

    PubMed

    Eitan, Zohar; Timmers, Renee

    2010-03-01

    Though auditory pitch is customarily mapped in Western cultures onto spatial verticality (high-low), both anthropological reports and cognitive studies suggest that pitch may be mapped onto a wide variety of other domains. We collected a total number of 35 pitch mappings and investigated in four experiments how these mappings are used and structured. In particular, we inquired (1) how Western subjects apply Western and non-Western metaphors to "high" and "low" pitches, (2) whether mappings applied in an abstract conceptual task are similarly applied by listeners to actual music, (3) how mappings of spatial height relate to these pitch mappings, and (4) how mappings of "high" and "low" pitch associate with other dimensions, in particular quantity, size, intensity and valence. The results show strong agreement among Western participants in applying familiar and unfamiliar metaphors for pitch, in both an abstract, conceptual task (Exp. 1) and in a music listening task (Exp. 2), indicating that diverse cross-domain mappings for pitch exist latently besides the common verticality metaphor. Furthermore, limited overlap between mappings of spatial height and pitch height was found, suggesting that, the ubiquity of the verticality metaphor in Western usage notwithstanding, cross-domain pitch mappings are largely independent of that metaphor, and seem to be based upon other underlying dimensions. Part of the discrepancy between spatial height and pitch height is that, for pitch, "up" is not necessarily "more," nor is it necessarily "good." High pitch is only "more" for height, intensity and brightness. It is "less" for mass, size and quantity. We discuss implications of these findings for music and speech prosody, and their relevance to notions of embodied cognition and of cross-domain magnitude representation. Copyright 2009 Elsevier B.V. All rights reserved.

  11. Volitional Spine Stabilization During a Drop Vertical Jump From Different Landing Heights: Implications for Anterior Cruciate Ligament Injury.

    PubMed

    Haddas, Ram; Hooper, Troy; James, C Roger; Sizer, Phillip S

    2016-12-01

    Volitional preemptive abdominal contraction (VPAC) during dynamic activities may alter trunk motion, but the role of the core musculature in positioning the trunk during landing tasks is unclear. To determine whether volitional core-muscle activation incorporated during a drop vertical jump alters lower extremity kinematics and kinetics, as well as trunk and lower extremity muscle activity at different landing heights. Controlled laboratory study. Clinical biomechanics laboratory. Thirty-two young healthy adults, consisting of 17 men (age = 25.24 ± 2.88 years, height = 1.85 ± 0.06 m, mass = 89.68 ± 16.80 kg) and 15 women (age = 23.93 ± 1.33 years, height = 1.67 ± 0.08 m, mass = 89.68 ± 5.28 kg). Core-muscle activation using VPAC. We collected 3-dimensional ankle, knee, and hip motions, moments, and powers; ground reaction forces; and trunk and lower extremity muscle activity during 0.30- and 0.50-m drop vertical-jump landings. During landing from a 0.30-m height, VPAC performance increased external oblique and semitendinosis activity, knee flexion, and knee internal rotation and decreased knee-abduction moment and knee-energy absorption. During the 0.50-m landing, the VPAC increased external oblique and semitendinosis activity, knee flexion, and hip flexion and decreased ankle inversion and hip-energy absorption. The VPAC performance during landing may protect the anterior cruciate ligament during different landing phases from different heights, creating a protective advantage just before ground contact and after the impact phase. Incorporating VPAC during high injury-risk activities may enhance pelvic stability, improve lower extremity positioning and sensorimotor control, and reduce anterior cruciate ligament injury risk while protecting the lumbar spine.

  12. Three-dimensional finite element analysis of vertical and angular misfit in implant-supported fixed prostheses.

    PubMed

    Assunção, Wirley Gonçalves; Gomes, Erica Alves; Rocha, Eduardo Passos; Delben, Juliana Aparecida

    2011-01-01

    Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 μm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 μm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 μm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system.

  13. Determinants of Transitional Zone Area and Porosity of the Proximal Femur Quantified In Vivo in Postmenopausal Women.

    PubMed

    Shigdel, Rajesh; Osima, Marit; Lukic, Marko; Ahmed, Luai A; Joakimsen, Ragnar M; Eriksen, Erik F; Bjørnerem, Åshild

    2016-04-01

    Bone architecture as well as size and shape is important for bone strength and risk of fracture. Most bone loss is cortical and occurs by trabecularization of the inner part of the cortex. We therefore wanted to identify determinants of the bone architecture, especially the area and porosity of the transitional zone, an inner cortical region with a large surface/matrix volume available for intracortical remodeling. In 211 postmenopausal women aged 54 to 94 years with nonvertebral fractures and 232 controls from the Tromsø Study, Norway, we quantified femoral subtrochanteric architecture in CT images using StrAx1.0 software, and serum levels of bone turnover markers (BTM, procollagen type I N-terminal propeptide and C-terminal cross-linking telopeptide of type I collagen). Multivariable linear and logistic regression analyses were used to quantify associations of age, weight, height, and bone size with bone architecture and BTM, and odds ratio (OR) for fracture. Increasing age, height, and larger total cross-sectional area (TCSA) were associated with larger transitional zone CSA and transitional zone CSA/TCSA (standardized coefficients [STB] = 0.11 to 0.80, p ≤ 0.05). Increasing weight was associated with larger TCSA, but smaller transitional zone CSA/TCSA and thicker cortices (STB = 0.15 to 0.22, p < 0.01). Increasing height and TCSA were associated with higher porosity of the transitional zone (STB = 0.12 to 0.46, p < 0.05). Increasing BTM were associated with larger TCSA, larger transitional zone CSA/TCSA, and higher porosity of each of the cortical compartments (p < 0.01). Fracture cases exhibited larger transitional zone CSA and higher porosity than controls (p < 0.001). Per SD increasing CSA and porosity of the transitional zone, OR for fracture was 1.71 (95% CI, 1.37 to 2.14) and 1.51 (95% CI, 1.23 to 1.85), respectively. Cortical bone architecture is determined mainly by bone size as built during growth and is modified by lifestyle factors throughout life through bone turnover. Fracture cases exhibited larger transitional zone area and porosity, highlighting the importance of cortical bone architecture for fracture propensity. © 2015 American Society for Bone and Mineral Research.

  14. A 24-year retrospective study of bone growth after implant placement.

    PubMed

    Roberts, Ralph A

    2005-01-01

    This study quantifies the changes in bone height noted in the body of the edentulous mandibles when the load of the complete denture is born by an RA Ramus Frame Implant (Pacific Implant, Rio Dell, Calif). Eighty-three patients with implants were followed for 3 to 24 years. Pre- and postoperative panoramic films were taken and again at each succeeding 5-year follow-up. The results of the bone changes were gathered retrospectively and calculated. The data revealed a significant increase in bone height from 4.413 to 13 mm and statistically significant P values of <.0003 were determined. The growth of bone appears to be influenced by the design of the posterior feet, dominant chewing side, and a range of extreme atrophy from 5.9 mm to 15 mm. Also, the previously lost anatomical structures appear to repair, such as the luman of the mental foramen and the superior wall over the inferior alveolar canal. All mandibles were loaded postoperatively with an appliance having cutting bars and porcelain teeth or just porcelain teeth in both appliances.

  15. Vertical Jump Height is more Strongly Associated with Velocity and Work Performed Prior to Take-off

    NASA Technical Reports Server (NTRS)

    Bentley, J. R.; Loehr, J. A.; DeWitt, J. K.; Lee, S. M. C.; English, K. L.; Nash, R. E.; Leach, M. A.; Hagan, R. D.

    2008-01-01

    Vertical jump (VJ) height is commonly used as a measure of athletic capability in strength and power sports. Although VJ has been shown to be a predictor of athletic performance, it is not clear which kinetic ground reaction force (GRF) variables, such as peak force (PF), peak power (PP), peak velocity (PV), total work (TW) or impulse (Imp) are the best correlates. To determine which kinetic variables (PF, PP, PV, TW, and Imp) best correlate with VJ height. Twenty subjects (14 males, 6 females) performed three maximal countermovement VJs on a force platform (Advanced Mechanical Technology, Inc., Watertown, MA, USA). VJ jump height was calculated as the difference between standing reach and the highest reach point measured using a Vertec. PF, PP, PV, TW, and Imp were calculated using the vertical GRF data sampled at 1000 Hz from the lowest point in the countermovement through the concentric portion until take-off. GRF data were normalized to body mass measured using a standard scale (Detecto, Webb City, MO, USA). Correlation coefficients were computed between each GRF variable and VJ height using a Pearson correlation. VJ height (43.4 plus or minus 9.1 cm) was significantly correlated (p less than 0.001) with PF (998 plus or minus 321 N; r=0.51), PP (1997 plus or minus 772 W; r=0.69), PV (2.66 plus or minus 0.40 m (raised dot) s(sup -1); r=0.85), TW (259 plus or minus 93.0 kJ; r=0.82), and Imp (204 plus or minus 51.1 N(raised dot)s; r=0.67). Although all variables were correlated to VJ height, PV and TW were more strongly correlated to VJ height than PF, PP, and Imp. Therefore, since TW is equal to force times displacement, the relative displacement of the center of mass along with the forces applied during the upward movement of the jump are critical determinants of VJ height. PV and TW are key determinants of VJ height, and therefore successful training programs to increase VJ height should focus on rapid movement (PV) and TW by increasing power over time rather than focusing on PF alone.

  16. Manifestations of Proprioception During Vertical Jumps to Specific Heights

    PubMed Central

    Struzik, Artur; Pietraszewski, Bogdan; Winiarski, Sławomir; Juras, Grzegorz; Rokita, Andrzej

    2017-01-01

    Abstract Artur, S, Bogdan, P, Kawczyński, A, Winiarski, S, Grzegorz, J, and Andrzej, R. Manifestations of proprioception during vertical jumps to specific heights. J Strength Cond Res 31(6): 1694–1701, 2017—Jumping and proprioception are important abilities in many sports. The efficiency of the proprioceptive system is indirectly related to jumps performed at specified heights. Therefore, this study recorded the ability of young athletes who play team sports to jump to a specific height compared with their maximum ability. A total of 154 male (age: 14.8 ± 0.9 years, body height: 181.8 ± 8.9 cm, body weight: 69.8 ± 11.8 kg, training experience: 3.8 ± 1.7 years) and 151 female (age: 14.1 ± 0.8 years, body height: 170.5 ± 6.5 cm, body weight: 60.3 ± 9.4 kg, training experience: 3.7 ± 1.4 years) team games players were recruited for this study. Each participant performed 2 countermovement jumps with arm swing to 25, 50, 75, and 100% of the maximum height. Measurements were performed using a force plate. Jump height and its accuracy with respect to a specified height were calculated. The results revealed no significant differences in jump height and its accuracy to the specified heights between the groups (stratified by age, sex, and sport). Individuals with a higher jumping accuracy also exhibited greater maximum jump heights. Jumps to 25% of the maximum height were approximately 2 times higher than the target height. The decreased jump accuracy to a specific height when attempting to jump to lower heights should be reduced with training, particularly among athletes who play team sports. These findings provide useful information regarding the proprioceptive system for team sport coaches and may shape guidelines for training routines by working with submaximal loads. PMID:28538322

  17. Anthropometric Sizing Systems for Army Women’s Field Clothing

    DTIC Science & Technology

    1981-03-01

    panties and bra (not pictured). HEIGHTS ANKLE HEIGHT (68): the height of the level of minimum circumference of the ankle. AXILLA HEIGHT (4): vertical...Patterson Air Force Base, Ohio, 1959. (AD 130 917) 3O’Brien, R., M.A. Girshick and E.P. Hunt. Body Measurements of American Boys and Girls for...O’Brien, Ruth, Meyer A. Girshick and Eleanor P. Hunt. 1941. Body Measurements of American Boys and Girls for Garment and Pattern Construction. U.S. De

  18. Sarcopenia Is Negatively Related to High Gravitational Impacts Achieved From Day-to-day Physical Activity.

    PubMed

    Hartley, April; Gregson, Celia L; Hannam, Kimberly; Deere, Kevin C; Clark, Emma M; Tobias, Jon H

    2018-04-17

    Sarcopenia has been associated with reduced physical activity (PA). We aimed to determine if sarcopenia, and specific components of muscle size, function, and physical performance, are associated with high impacts achieved during habitual PA, as these are related to bone strength in community-dwelling older women. Participants were older women from the Cohort of Skeletal Health in Bristol and Avon. We defined sarcopenia using the EWGSOP criteria. Lower limb peak muscle power and force were assessed using Jumping Mechanography (JM). High vertical impacts were assessed by tri-axial accelerometry (at least 1.5g above gravity). Cross-sectional associations were analyzed by linear regression, adjusting for age, height and weight (or fat mass for models including appendicular lean mass index), comorbidities, smoking, alcohol, and Index of Multiple Deprivation. Our analyses included 380 participants, with mean age 76.7 (SD 3.0) years; 242 (64%) also completed JM. In age-adjusted analysis, a negative relationship was observed between severity of sarcopenia and high, but not medium or low, impacts (p = .03 for trend). Regarding components of sarcopenia underlying this relationship, multivariable analyses revealed that gait speed (β 1.47 [95% CI 1.14, 1.89], [β-1] reflects the proportionate increase in high impacts per SD increase in exposure) and peak force (1.40 [1.07, 1.84]) were independently associated with high impacts. Older women with sarcopenia experienced fewer bone-strengthening high impacts than those with presarcopenia or without sarcopenia. To increase bone strengthening activity in older women, interventions need to improve both lower limb muscle force and walking speed.

  19. Clinical Outcomes of Vertical Distraction Osteogenesis for Dental Implantation: A Systematic Review and Meta-Analysis.

    PubMed

    Zhao, Kai; Wang, Feng; Huang, Wei; Wu, Yiqun

    The aim of this study was to evaluate the clinical outcomes of vertical distraction osteogenesis (VDO) for patients with vertically deficient alveolar ridges in terms of (1) the cumulative implant survival rate, (2) bone gain, (3) bone resorption before and after implant insertion, and (4) complications. An electronic search was conducted via MEDLINE (PubMed), EMBASE, and the Cochrane Library, complemented by manual searches, to identify eligible clinical studies of VDO before dental implantation. Two reviewers independently performed the study selection and data extraction. The implant survival rate, mean bone gain, and bone resorption amount, with 95% confidence intervals (CIs), were pooled separately. A random-effects model or fixed-effects model was chosen based on the heterogeneity. A funnel plot and Egger's test were performed to identify publication bias. Of the 4,391 records after removal of duplicates, 113 full-text articles were obtained for further analysis, and 12 articles were ultimately included in the analysis. Two studies were defined as low quality. The estimated cumulative implant survival rate was 98.00% (95% CI: 96.02% to 99.40%), with a mean follow-up of 3.52 years. The bone gain was 7.92 mm (95% CI: 6.27 to 9.57 mm), with a range from 4 to 20 mm, and the level of bone relapse between the end of the distraction and the implant insertion was 0.97 mm (95% CI: 0.68 to 1.26 mm). The complication rate was high, with rates of 0.728 per site and 0.821 per patient. The most common major complication was basal bone fracture, with a rate of 2.27%, and the most common minor complication was displacement of the transport segments, with a rate of 16.71%. Vertical alveolar defects could be rehabilitated successfully with distraction osteogenesis, and the implant placed in the distraction sites showed a high cumulative survival rate. However, the high complication rate necessitates caution. Due to the observed heterogeneity, the results of this meta-analysis should be interpreted with caution.

  20. Impact of skeletal maturation on bone metabolism biomarkers and bone mineral density in healthy Brazilian male adolescents.

    PubMed

    Silva, Carla C; Goldberg, Tamara B L; Nga, Hong S; Kurokawa, Cilmery S; Capela, Renata C; Teixeira, Altamir S; Dalmas, José C

    2011-01-01

    To evaluate the behavior of biomarkers of bone formation and resorption in healthy male Brazilian adolescents according to their biological maturation. Eighty-seven volunteers were divided into age groups according to bone age (BA): 10-12 years (n = 25), 13-15 years (n = 36), and 16-18 years (n = 26). Weight (kg), height (m), body mass index (kg/m(2)), calcium intake from 3 days assessed by 24-h food recall (mg/day), pubertal event evaluation by Tanner criteria, and serum biomarker levels (osteocalcin [OC] [ng/mL], bone alkaline phosphatase [BAP] [U/L], and serum carboxyterminal telopeptide [S-CTx] [ng/mL]) were recorded and correlated to bone mineral density (BMD) (g/cm(2)) measured by dual energy X-ray absorptiometry of the lumbar spine, proximal femur, and whole body. Biomarkers showed similar behaviors, presenting higher median values in the 13-15 year group (BAP = 154.71 U/L, OC = 43.0 ng/mL, S-CTx = 2.09 ng/mL; p < 0.01) and when adolescents were in the pubertal stage G4. Median biomarker values decreased with advancing BA and sexual maturation. Biomarker values showed parallelism with peak height velocity, and, interestingly, bone formation biomarkers indicated significant negative correlation with BMD in the different evaluated locations, i.e., higher BMD values correlated with lower bone biomarker values. This is the first study of healthy Brazilian adolescents with rigid and careful inclusion and exclusion criteria to assess the correlation of bone markers and BMD with biological maturation indicators. Our results can help understand bone turnover and monitor bone metabolism.

  1. Research on Inversion Models for Forest Height Estimation Using Polarimetric SAR Interferometry

    NASA Astrophysics Data System (ADS)

    Zhang, L.; Duan, B.; Zou, B.

    2017-09-01

    The forest height is an important forest resource information parameter and usually used in biomass estimation. Forest height extraction with PolInSAR is a hot research field of imaging SAR remote sensing. SAR interferometry is a well-established SAR technique to estimate the vertical location of the effective scattering center in each resolution cell through the phase difference in images acquired from spatially separated antennas. The manipulation of PolInSAR has applications ranging from climate monitoring to disaster detection especially when used in forest area, is of particular interest because it is quite sensitive to the location and vertical distribution of vegetation structure components. However, some of the existing methods can't estimate forest height accurately. Here we introduce several available inversion models and compare the precision of some classical inversion approaches using simulated data. By comparing the advantages and disadvantages of these inversion methods, researchers can find better solutions conveniently based on these inversion methods.

  2. Vertical Structure of NGC 4631

    NASA Astrophysics Data System (ADS)

    Ann, Hong Bae; Seo, Mira Seo; Baek, Su-Ja

    2011-02-01

    We present a deep CCD imaging in B and V bands which allows us to analyze the vertical structure of NGC 4631. We derive the scale heights of the thin and thick disks at a variety of positions along the major axis of the disk. The scale heights of the thin disk are nearly constant while those of the thick disk tend to increase with increasing galactocentric distance. The mean scale heights of the thin disk derived from B and V images are similar to each other (˜450 pc). Instead, those of the thick disk show a strong east-west asymmetry which is caused by the diffuse stellar emission that is most prominent in the north west regions above the disk plane. The ratio of scale heights (z_{thick}/z_{thin}) is about 2.5 in the east side of the disk. However, this ratio is greater than 4 for the thick disk above the disk plane in the west side of the galaxy.

  3. How components of facial width to height ratio differently contribute to the perception of social traits

    PubMed Central

    Lio, Guillaume; Gomez, Alice; Sirigu, Angela

    2017-01-01

    Facial width to height ratio (fWHR) is a morphological cue that correlates with sexual dimorphism and social traits. Currently, it is unclear how vertical and horizontal components of fWHR, distinctly capture faces’ social information. Using a new methodology, we orthogonally manipulated the upper facial height and the bizygomatic width to test their selective effect in the formation of impressions. Subjects (n = 90) saw pair of faces and had to select the face expressing better different social traits (trustworthiness, aggressiveness and femininity). We further investigated how sex and fWHR components interact in the formation of these judgements. Across experiments, changes along the vertical component better predicted participants' ratings rather than the horizontal component. Faces with smaller height were perceived as less trustworthy, less feminine and more aggressive. By dissociating fWHR and testing the contribution of its components independently, we obtained a powerful and discriminative measure of how facial morphology guides social judgements. PMID:28235081

  4. Are adult patients with Laron syndrome osteopenic? A comparison between dual-energy X-ray absorptiometry and volumetric bone densities.

    PubMed

    Benbassat, Carlos A; Eshed, Varda; Kamjin, Moshe; Laron, Zvi

    2003-10-01

    Severe short stature resulting from a deficiency in IGF-I is a prominent feature of Laron syndrome (LS). Although low bone mineral density (BMD) has been noted in LS patients examined by dual energy x-ray absorptiometry (DEXA), this technique does not take volume into account and may therefore underestimate the true bone density in patients with small bones. The aim of the present study was to evaluate the BMD yielded by DEXA in our LS patients using estimated volumetric values. Volumetric density was calculated with the following formulas: bone mineral apparent density (BMAD) = bone mineral content (BMC)/(area)(3/2) for the lumbar spine and BMAD = BMC/area(2) for the femoral neck. The study sample included 12 patients (mean age, 43.9 yr; mean height, 123.7 cm). Findings were compared with 10 osteopenic subjects without developmental abnormalities (mean age, 56 yr; mean height, 164.8 cm) and 10 healthy control subjects matched for sex and age to the LS patients (mean height, 165.5 cm). BMAD in the LS group was 0.201 +/- 0.02 g/cm(3) at the lumbar spine and 0.201 +/- 0.04 g/cm(3) at the femoral neck; corresponding values for the osteopenic group were 0.130 +/- 0.01 and 0.140 +/- 0.01 g/cm(3), and for the controls, 0.178 +/- 0.03 and 0.192 +/- 0.02 g/cm(3). Although areal BMD was significantly lower in the LS and osteopenic subjects compared with controls (P < 0.02) at both the lumbar spine and femoral neck, BMAD was low (P < 0.01) in the osteopenic group only. In conclusion, DEXA does not seem to be a reliable measure of osteoporosis in patients with LS.

  5. International longitudinal pediatric reference standards for bone mineral content.

    PubMed

    Baxter-Jones, Adam D G; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don; McKay, Heather

    2010-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site-specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women's Health Study (n=112) and Stanford's Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement between predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (P<0.05). Compared to White males, Asian males had 31.8 (6.8) g less WB BMC accrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. We report similar findings for the PF and FN. Models for females for all sites were similar with age, height and weight as independent significant predictors of BMC accrual (P<0.05). We provide a tool to calculate a child's BMC Z-score, accounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in pediatrics we recommend standards that are sex, age, size and ethnic specific. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  6. International Longitudinal Paediatric Reference Standards for Bone Mineral Content

    PubMed Central

    Baxter-Jones, Adam DG; McKay, Heather; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don

    2014-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women’s Health Study (n=112) and Stanford’s Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement in predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (P <0.05). Compared to White males, Asian males had 31.8 (6.8) g less WB BMC accrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. Similar findings were found for PF and FN. Female models for all sites were similar with age, height and weight all independent significant predictors of BMC accrual (P <0.05). We provide a tool to calculate a child’s BMC Z-score, accounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in paediatrics we recommend standards that are sex, age, size and ethnic specific. PMID:19854308

  7. Extensive BMI Gain in Puberty is Associated with Lower Increments in Bone Mineral Density in Estonian Boys with Overweight and Obesity: A 3-Year Longitudinal Study.

    PubMed

    Mengel, Eva; Tillmann, Vallo; Remmel, Liina; Kool, Pille; Purge, Priit; Lätt, Evelin; Jürimäe, Jaak

    2017-08-01

    The aim of this 3-year prospective study was to examine changes in bone mineral characteristics during pubertal maturation in boys with different BMI values at the beginning of puberty and with different BMI increments during puberty. 26 boys with overweight and obesity (OWB) and 29 normal weight boys (NWB) were studied yearly for 3 years from the age of 11 years to measure the changes in different bone mineral characteristics. The OWB group was further divided into two subgroups according to extensive or non-extensive BMI increment during 3-year period. OWB had higher (P < 0.01) baseline total body (TB) bone mineral density (BMD), TB bone mineral content (BMC), TB BMC for height, lumbar spine (LS) BMD, and LS BMC compared to NWB. Throughout the study period, OWB gained more TB BMD (P = 0.0001), TB BMC (P = 0.0048), TB BMC for height (P = 0.0124), LS BMD (P = 0.0029), and LS BMC (P = 0.0022) compared to NWB. Also during the study period, TB BMD (P = 0.0065), TB BMC (P = 0.0141), TB BMC for height (P = 0.0199), LS BMD (P = 0.0066), LS apparent volumetric BMD (BMAD) (P = 0.0075), and LS BMC (P = 0.017) increased significantly less in those OWB whose BMI increased more extensively. Extensive BMI gain is associated with lower increments in bone mineral characteristics in boys with overweight and obesity. Unfavorable increment in total body fat mass and percentage during pubertal years could be one reason for that.

  8. Age-related new bone formation following the use of cancellous bone-block allografts for reconstruction of atrophic alveolar ridges.

    PubMed

    Nissan, Joseph; Kolerman, Roni; Chaushu, Liat; Vered, Marilena; Naishlos, Sarit; Chaushu, Gavriel

    2018-02-01

    An age-related decrease in the number of osteogenic progenitor cells may compromise bone augmentation. Histomorphometrical assessment of age-related new bone formation, following atrophic alveolar ridge reconstruction, using cancellous bone-block allografts. Ninety-three consecutive patients (58 females and 35 males) were referred for implant-supported restoration of 122 severe atrophic alveolar ridges. Alveolar ridge deficiency locations were classified as anterior maxilla (n = 58), posterior maxilla (n= 32), and posterior mandible (n = 32). A bony deficiency of at least 3 mm horizontally and up to 3 mm vertically according to computerized tomography (CT) in the posterior mandible and anterior maxilla, served as inclusion criteria. In the posterior maxilla, a residual alveolar ridge up to 4 mm vertically according to CT served as inclusion criteria. Augmentation was performed by the use of cancellous bone-block allografts. Bone biopsies (9-month posterior maxilla, 4 months anterior maxilla and posterior mandible) of young (≤40 years) versus older (>40 years) patients were histomorphometrically evaluated. In the posterior maxilla, no statistically significant histomorphometric differences were noted. While at the anterior maxilla and posterior mandible, statistically significant more newly formed bone was found in young versus older individuals, respectively (38.6% vs 19.8%, P = 0.04 and 69% vs 31%, P = .05). New bone formation following residual alveolar ridge bone grafting is age-related. Longer bone consolidation and healing time may be recommended for older individuals. © 2017 Wiley Periodicals, Inc.

  9. Numerical modelling of flow structures over idealized transverse aeolian dunes of varying geometry

    NASA Astrophysics Data System (ADS)

    Parsons, Daniel R.; Walker, Ian J.; Wiggs, Giles F. S.

    2004-04-01

    A Computational Fluid Dynamics (CFD) model (PHOENICS™ 3.5) previously validated for wind tunnel measurements is used to simulate the streamwise and vertical velocity flow fields over idealized transverse dunes of varying height ( h) and stoss slope basal length ( L). The model accurately reproduced patterns of: flow deceleration at the dune toe; stoss flow acceleration; vertical lift in the crest region; lee-side flow separation, re-attachment and reversal; and flow recovery distance. Results indicate that the flow field over transverse dunes is particularly sensitive to changes in dune height, with an increase in height resulting in flow deceleration at the toe, streamwise acceleration and vertical lift at the crest, and an increase in the extent of, and strength of reversed flows within, the lee-side separation cell. In general, the length of the separation zone varied from 3 to 15 h from the crest and increased over taller, steeper dunes. Similarly, the flow recovery distance ranged from 45 to >75 h and was more sensitive to changes in dune height. For the range of dune shapes investigated in this study, the differing effects of height and stoss slope length raise questions regarding the applicability of dune aspect ratio as a parameter for explaining airflow over transverse dunes. Evidence is also provided to support existing research on: streamline curvature and the maintenance of sand transport in the toe region; vertical lift in the crest region and its effect on grainfall delivery; relations between the turbulent shear layer and downward forcing of flow re-attachment; and extended flow recovery distances beyond the separation cell. Field validation is required to test these findings in natural settings. Future applications of the model will characterize turbulence and shear stress fields, examine the effects of more complex isolated dune forms and investigate flow over multiple dunes.

  10. An automatic early stage alveolar-bone-resorption evaluation method on digital dental panoramic radiographs

    NASA Astrophysics Data System (ADS)

    Zhang, Min; Katsumata, Akitoshi; Muramatsu, Chisako; Hara, Takeshi; Suzuki, Hiroki; Fujita, Hiroshi

    2014-03-01

    Periodontal disease is a kind of typical dental diseases, which affects many adults. The presence of alveolar bone resorption, which can be observed from dental panoramic radiographs, is one of the most important signs of the progression of periodontal disease. Automatically evaluating alveolar-bone resorption is of important clinic meaning in dental radiology. The purpose of this study was to propose a novel system for automated alveolar-bone-resorption evaluation from digital dental panoramic radiographs for the first time. The proposed system enables visualization and quantitative evaluation of alveolar bone resorption degree surrounding the teeth. It has the following procedures: (1) pre-processing for a test image; (2) detection of tooth root apices with Gabor filter and curve fitting for the root apex line; (3) detection of features related with alveolar bone by using image phase congruency map and template matching and curving fitting for the alveolar line; (4) detection of occlusion line with selected Gabor filter; (5) finally, evaluation of the quantitative alveolar-bone-resorption degree in the area surrounding teeth by simply computing the average ratio of the height of the alveolar bone and the height of the teeth. The proposed scheme was applied to 30 patient cases of digital panoramic radiographs, with alveolar bone resorption of different stages. Our initial trial on these test cases indicates that the quantitative evaluation results are correlated with the alveolar-boneresorption degree, although the performance still needs further improvement. Therefore it has potential clinical practicability.

  11. Effect of framework material and vertical misfit on stress distribution in implant-supported partial prosthesis under load application: 3-D finite element analysis.

    PubMed

    Bacchi, Ataís; Consani, Rafael Leonardo Xediek; Mesquita, Marcelo Ferraz; Dos Santos, Mateus Bertolini Fernandes

    2013-09-01

    This study evaluated the influence of framework material and vertical misfit on stress created in an implant-supported partial prosthesis under load application. The posterior part of a severely reabsorbed jaw with a fixed partial prosthesis above two osseointegrated titanium implants at the place of the second premolar and second molar was modeled using SolidWorks 2010 software. Finite element models were obtained by importing the solid model into an ANSYS Workbench 11 simulation. The models were divided into 15 groups according to their prosthetic framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy or zirconia) and vertical misfit level (10 µm, 50 µm and 100 µm). After settlement of the prosthesis with the closure of the misfit, simultaneous loads of 110 N vertical and 15 N horizontal were applied on the occlusal and lingual faces of each tooth, respectively. The data was evaluated using Maximum Principal Stress (framework, porcelain veneer and bone tissue) and a von Mises Stress (retention screw) provided by the software. As a result, stiffer frameworks presented higher stress concentrations; however, these frameworks led to lower stresses in the porcelain veneer, the retention screw (faced to 10 µm and 50 µm of the misfit) and the peri-implant bone tissues. The increase in the vertical misfit resulted in stress values increasing in all of the prosthetic structures and peri-implant bone tissues. The framework material and vertical misfit level presented a relevant influence on the stresses for all of the structures evaluated.

  12. Peak bone mass and patterns of change in total bone mineral density and bone mineral contents from childhood into young adulthood

    PubMed Central

    Lu, Juan; Shin, Yongyun; Yen, Miao-Shan; Sun, Shumei S.

    2014-01-01

    The literature has not reached a consensus on the age when peak bone mass is achieved. This study examines growth patterns of TBMC and TBMD, peak bone mass, effect of concurrent anthropometry measures and physical activity on growth patterns in a sample of 312 white males and 343 females aged eight to 30 years. We analyzed data from participants enrolled in Fels Longitudinal Study. Descriptive analysis was used to ascertain characteristics of participants and growth patterns of TBMC and TBMD. Mixed effects models were applied to predict ages at attainment of peak TBMC and TBMD and assess effects of height, weight, BMI and habitual physical activity on the attainment. Significant differences between sexes were observed for measures of TBMC and TBMD, and differences varied with age. For females, predicted median ages at peak TBMC and TBMD attainments are 21.96 (IQR: 21.81–22.21) and 22.31 (IQR: 21.95–22.59) years, respectively. For males, predicted median ages are 23.34 (IQR: 24.34–26.19) and 26.86 (IQR: 25.14–27.98) respectively. For females, height, weight and BMI, but not physical activity, had significant influences on attainment of TBMC and TBMD (P <0.01). For males, weight and BMI, but not height and physical activity, exerted significant influence on attainment of TBMC and TBMD (P<0.01), and also modified correlations between age and peak TBMC and TBMD. Our results suggest that (1) for both sexes, trajectories of TBMC and TBMD follow a curvilinear pattern between ages eight and 30 years; (2) predicted ages at peak TBMC and TBMD are from early to late 20s for both white males and females, with females reaching their peaks significantly earlier than males; and (3) concurrent height, weight and BMI, but not habitual physical activity, exert significant effects on trajectories of TBMC and TBMD. PMID:25440183

  13. Alveolar ridge preservation after tooth extraction: a Bayesian Network meta-analysis of grafting materials efficacy on prevention of bone height and width reduction.

    PubMed

    Iocca, Oreste; Farcomeni, Alessio; Pardiñas Lopez, Simon; Talib, Huzefa S

    2017-01-01

    To conduct a traditional meta-analysis and a Bayesian Network meta-analysis to synthesize the information coming from randomized controlled trials on different socket grafting materials and combine the resulting indirect evidence in order to make inferences on treatments that have not been compared directly. RCTs were identified for inclusion in the systematic review and subsequent statistical analysis. Bone height and width remodelling were selected as the chosen summary measures for comparison. First, a series of pairwise meta-analyses were performed and overall mean difference (MD) in mm with 95% CI was calculated between grafted versus non-grafted sockets. Then, a Bayesian Network meta-analysis was performed to draw indirect conclusions on which grafting materials can be considered most likely the best compared to the others. From the six included studies, seven comparisons were obtained. Traditional meta-analysis showed statistically significant results in favour of grafting the socket compared to no-graft both for height (MD 1.02, 95% CI 0.44-1.59, p value < 0.001) than for width (MD 1.52 95% CI 1.18-1.86, p value <0.000001) remodelling. Bayesian Network meta-analysis allowed to obtain a rank of intervention efficacy. On the basis of the results of the present analysis, socket grafting seems to be more favourable than unassisted socket healing. Moreover, Bayesian Network meta-analysis indicates that freeze-dried bone graft plus membrane is the most likely effective in the reduction of bone height remodelling. Autologous bone marrow resulted the most likely effective when width remodelling was considered. Studies with larger samples and less risk of bias should be conducted in the future in order to further strengthen the results of this analysis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Wind-tunnel Modelling of Dispersion from a Scalar Area Source in Urban-Like Roughness

    NASA Astrophysics Data System (ADS)

    Pascheke, Frauke; Barlow, Janet F.; Robins, Alan

    2008-01-01

    A wind-tunnel study was conducted to investigate ventilation of scalars from urban-like geometries at neighbourhood scale by exploring two different geometries a uniform height roughness and a non-uniform height roughness, both with an equal plan and frontal density of λ p = λ f = 25%. In both configurations a sub-unit of the idealized urban surface was coated with a thin layer of naphthalene to represent area sources. The naphthalene sublimation method was used to measure directly total area-averaged transport of scalars out of the complex geometries. At the same time, naphthalene vapour concentrations controlled by the turbulent fluxes were detected using a fast Flame Ionisation Detection (FID) technique. This paper describes the novel use of a naphthalene coated surface as an area source in dispersion studies. Particular emphasis was also given to testing whether the concentration measurements were independent of Reynolds number. For low wind speeds, transfer from the naphthalene surface is determined by a combination of forced and natural convection. Compared with a propane point source release, a 25% higher free stream velocity was needed for the naphthalene area source to yield Reynolds-number-independent concentration fields. Ventilation transfer coefficients w T / U derived from the naphthalene sublimation method showed that, whilst there was enhanced vertical momentum exchange due to obstacle height variability, advection was reduced and dispersion from the source area was not enhanced. Thus, the height variability of a canopy is an important parameter when generalising urban dispersion. Fine resolution concentration measurements in the canopy showed the effect of height variability on dispersion at street scale. Rapid vertical transport in the wake of individual high-rise obstacles was found to generate elevated point-like sources. A Gaussian plume model was used to analyse differences in the downstream plumes. Intensified lateral and vertical plume spread and plume dilution with height was found for the non-uniform height roughness.

  15. A stingless bee can use visual odometry to estimate both height and distance.

    PubMed

    Eckles, M A; Roubik, D W; Nieh, J C

    2012-09-15

    Bees move and forage within three dimensions and rely heavily on vision for navigation. The use of vision-based odometry has been studied extensively in horizontal distance measurement, but not vertical distance measurement. The honey bee Apis mellifera and the stingless bee Melipona seminigra measure distance visually using optic flow-movement of images as they pass across the retina. The honey bees gauge height using image motion in the ventral visual field. The stingless bees forage at different tropical forest canopy levels, ranging up to 40 m at our site. Thus, estimating height would be advantageous. We provide the first evidence that the stingless bee Melipona panamica utilizes optic flow information to gauge not only distance traveled but also height above ground, by processing information primarily from the lateral visual field. After training bees to forage at a set height in a vertical tunnel lined with black and white stripes, we observed foragers that explored a new tunnel with no feeder. In a new tunnel, bees searched at the same height they were trained to. In a narrower tunnel, bees experienced more image motion and significantly lowered their search height. In a wider tunnel, bees experienced less image motion and searched at significantly greater heights. In a tunnel without optic cues, bees were disoriented and searched at random heights. A horizontal tunnel testing these variables similarly affected foraging, but bees exhibited less precision (greater variance in search positions). Accurately gauging flight height above ground may be crucial for this species and others that compete for resources located at heights ranging from ground level to the high tropical forest canopies.

  16. Biophysical constraints on leaf expansion in a tall conifer.

    PubMed

    Meinzer, Frederick C; Bond, Barbara J; Karanian, Jennifer A

    2008-02-01

    The physiological mechanisms responsible for reduced extension growth as trees increase in height remain elusive. We evaluated biophysical constraints on leaf expansion in old-growth Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco) trees. Needle elongation rates, plastic and elastic extensibility, bulk leaf water (Psi(L)) and osmotic (Psi(pi)) potential, bulk tissue yield threshold and final needle length were characterized along a height gradient in crowns of > 50-m-tall trees during the period between bud break and full expansion (May to June). Although needle length decreased with increasing height, there was no height-related trend in leaf plastic extensibility, which was highest immediately after bud break (2.9%) and declined rapidly to a stable minimum value (0.3%) over a 3-week period during which leaf expansion was completed. There was a significant positive linear relationship between needle elongation rates and plastic extensibility. Yield thresholds were consistently lower at the upper and middle crown sampling heights. The mean yield threshold across all sampling heights was 0.12 +/- 0.03 MPa on June 8, rising to 0.34 +/- 0.03 MPa on June 15 and 0.45 +/- 0.05 MPa on June 24. Bulk leaf Psi(pi) decreased linearly with increasing height at a rate of 0.004 MPa m(-1) during the period of most rapid needle elongation, but the vertical osmotic gradient was not sufficient to fully compensate for the 0.015 MPa m(-1) vertical gradient in Psi(L), implying that bulk leaf turgor declined at a rate of about 0.011 MPa m(-1) increase in height. Although height-dependent reductions in turgor appeared to constrain leaf expansion, it is possible that the impact of reduced turgor was mitigated by delayed phenological development with increasing height, which resulted in an increase with height in the temperature during leaf expansion.

  17. Enzyme replacement therapy for mucopolysaccharidosis VI: Growth and pubertal development in patients treated with recombinant human N-acetylgalactosamine 4-sulfatase

    PubMed Central

    Decker, Celeste; Yu, Zi-Fan; Giugliani, Roberto; Schwartz, Ida Vanessa D.; Guffon, Nathalie; Teles, Elisa Leão; Miranda, M. Clara Sá; Wraith, J. Edmond; Beck, Michael; Arash, Laila; Scarpa, Maurizio; Ketteridge, David; Hopwood, John J.; Plecko, Barbara; Steiner, Robert; Whitley, Chester B.; Kaplan, Paige; Swiedler, Stuart J.; Conrad, Susan; Harmatz, Paul

    2010-01-01

    Background and Methods Growth failure is characteristic of untreated mucopolysaccharidosis type VI (MPS VI: Maroteaux-Lamy syndrome). Growth was studied in fifty-six MPS VI patients (5 to 29 years old) prior to and for up to 240 weeks of weekly infusions of recombinant human arylsulfatase B (rhASB) at 1 mg/kg during Phase 1/2, Phase 2, Phase 3 or Phase 3 Extension clinical trials. Height, weight, and Tanner stage data were collected. Pooled data were analyzed to determine mean height increase by treatment week, growth impacts of pubertal status, baseline urinary GAG, and age at treatment initiation. Growth rate for approximately 2 years prior to and following treatment initiation was analyzed using longitudinal modeling. Results Mean height increased by 2.9 cm after 48 weeks and 4.3 cm after 96 weeks on enzyme replacement therapy (ERT). Growth on ERT was not correlated with baseline urinary GAG. Patients under 16 years of age showed greatest increases in height on treatment. Model results based on pooled data showed significant improvement in growth rate during 96 weeks of ERT when compared to the equivalent pretreatment time period. Delayed pubertal onset or progression was noted in 10 patients entering the clinical trials; all of whom showed progression of at least one Tanner stage during 2 years on ERT, and 6 of whom (60%) completed puberty. Conclusion Analysis of mean height by treatment week and longitudinal modeling demonstrate significant increase in height and growth rate in MPS VI patients receiving long-term ERT. This impact was greatest in patients aged below 16 years. Height increase may result from bone growth and/or reduction in joint contractures. Bone growth and resolution of delayed puberty may be related to improvements in general health, bone cell health, nutrition, endocrine gland function and reduced inflammation. PMID:20634905

  18. Measurement of Lacrimal Sac Fossa Using Orbital Computed Tomography.

    PubMed

    Kang, Dongwan; Park, Jinhwan; Na, Jaehoon; Lee, Hwa; Baek, Sehyun

    2017-01-01

    To evaluate the clinical usefulness of measuring the lacrimal sac fossa length using orbital computed tomography in normal Koreans. The authors retrospectively evaluated 140 patients (70 males and 70 females) who underwent orbital computed tomography at Guro Hospital and who had no history of orbital disease or orbital trauma. Computed tomography scans of the right orbit, including the proportion of the lacrimal bone and maxillary bone that comprise the lacrimal sac fossa, were evaluated at 3 different axial planes (lower, middle, and upper levels). Additionally, the mid-point thickness and maximum thickness of the maxillary bone were measured. Finally, the authors also evaluated the relationship between nasal bone height and maxillary bone thickness in the lacrimal sac fossa. Maxillary bone thickness in the lacrimal sac fossa was thicker in males than in females at mid-point thickness and maximum thickness (P < 0.05). However, there was no significant difference in the size of the lacrimal sac fossa and the proportion of the maxillary bone between males and females.In comparisons between maxillary cross-sections, bone thickness was greater toward the upper level of the lacrimal sac fossa (P = 0.008), and the proportion of the maxillary bone was also greater (P = 0.006).Aging had a significant positive correlation with maxillary bone thickness at all 3 axial planes (P < 0.05), but there was no relationship between age and maxillary bone proportion. Nasal bone height and maxillary bone thickness were also not significantly related. In comprising the lacrimal sac fossa, the maxillary bone accounted for a bigger proportion than the lacrimal bone. Male maxillary bone thickness was greater than female thickness. The authors also observed that maxillary bone thickness increased toward the upper areas of the lacrimal sac fossa and with increasing subject age. Understanding the form and variation of a normal lacrimal sac fossa is helpful for preparing for a successful osteotomy with endoscopic dacryocystorhinostomy.

  19. Estimating Glenoid Width for Instability-Related Bone Loss: A CT Evaluation of an MRI Formula.

    PubMed

    Giles, Joshua W; Owens, Brett D; Athwal, George S

    2015-07-01

    Determining the magnitude of glenoid bone loss in cases of shoulder instability is an important step in selecting the optimal reconstructive procedure. Recently, a formula has been proposed that estimates native glenoid width based on magnetic resonance imaging (MRI) measurements of height (1/3 × glenoid height + 15 mm). This technique, however, has not been validated for use with computed tomography (CT), which is often the preferred imaging modality to assess bone deficiencies. The purpose of this project was 2-fold: (1) to determine if the MRI-based formula that predicts glenoid width from height is valid with CT and (2) to determine if a more accurate regression can be resolved for use specifically with CT data. Descriptive laboratory study. Ninety normal shoulder CT scans with preserved osseous anatomy were drawn from an existing database and analyzed. Measurements of glenoid height and width were performed by 2 observers on reconstructed 3-dimensional models. After assessment of reliability, the data were correlated, and regression models were created for male and female shoulders. The accuracy of the MRI-based model's predictions was then compared with that of the CT-based models. Intra- and interrater reliabilities were good to excellent for height and width, with intraclass correlation coefficients of 0.765 to 0.992. The height and width values had a strong correlation of 0.900 (P < .001). Regression analyses for male and female shoulders produced CT-specific formulas: for men, glenoid width = 2/3 × glenoid height + 5 mm; for women, glenoid width = 2/3 × glenoid height + 3 mm. Comparison of predictions from the MRI- and CT-specific formulas demonstrated good agreement (intraclass correlation coefficient = 0.818). The CT-specific formulas produced a root mean squared error of 1.2 mm, whereas application of the MRI-specific formula to CT images resulted in a root mean squared error of 1.5 mm. Use of the MRI-based formula on CT scans to predict glenoid width produced estimates that were nearly as accurate as the CT-specific formulas. The CT-specific formulas, however, are more accurate at predicting native glenoid width when applied to CT data. Imaging-specific (CT and MRI) formulas have been developed to estimate glenoid bone loss in patients with instability. The CT-specific formula can accurately predict native glenoid width, having an error of only 2.2% of average glenoid width. © 2015 The Author(s).

  20. Comparing helicopter-borne profiling radar with airborne laser scanner data for forest structure estimation.

    NASA Astrophysics Data System (ADS)

    Piermattei, Livia; Hollaus, Markus; Pfeifer, Norbert; Chen, Yuwei; Karjalainen, Mika; Hakala, Teemu; Hyyppä, Juha; Wagner, Wolfgang

    2017-04-01

    Forests are complex ecosystems that show substantial variation with respect to climate, management regime, stand history, disturbance, and needs of local communities. The dynamic processes of growth and disturbance are reflected in the structural components of forests that include the canopy vertical structure and geometry (e.g. size, height, and form), tree position and species diversity. Current remote-sensing systems to measure forest structural attributes include passive optical sensors and active sensors. The technological capabilities of active remote sensing like the ability to penetrate the vegetation and provide information about its vertical structure has promoted an extensive use of LiDAR (Light Detection And Ranging) and radar (RAdio Detection And Ranging) system over the last 20 years. LiDAR measurements from aircraft (airborne laser scanning, ALS) currently represents the primary data source for three-dimensional information on forest vertical structure. Contrary, despite the potential of radar remote sensing, their use is not yet established in forest monitoring. In order to better understand the interaction of pulsed radar with the forest canopy, and to increase the feasibility of this system, the Finnish Geospatial Research Institute has developed a helicopter-borne profiling radar system, called TomoRadar. TomoRadar is capable of recording a canopy-penetrating profile of forests. To georeference the radar measurements the system was equipped with a global navigation satellite system and an inertial measurement unit with a centimeter level accuracy of the flight trajectory. The TomoRadar operates at Ku-band, (wave lengths λ 1.5cm) with two separated parabolic antennas providing co- and cross-polarization modes. The purpose of this work is to investigate the capability of the TomoRadar system, for estimating the forest vertical profile, terrain topography and tree height. We analysed 600 m TomoRadar crosspolarized (i.e. horizontal - vertical) profile, acquired in October 2016 over a boreal test site in Evo, Finland. The intensity of the reflected backscatter energy was used to measure the height canopy distribution within an individual footprint. As the intensity of the backscatter energy from the ground is exceeding the intensity from vegetation, the estimation of canopy height and the forest structure were based on i) a threshold between canopy and ground and ii) a peak analysis of the backscattering profile. ALS data collected simultaneously was used to validate the TomoRadar results (i.e. canopy height) and to obtain elevation ground truth. The first results show a high agreement between ALS and TomoRadar derived canopy heights. The derived knowledge about the energy distribution within the canopy height profile leads to an increased understanding of the interactions between the radar signal and the forest canopy and will support optimization of future radar systems with respect to forest structure observation.

  1. Use of coastal altimeter and tide gauge data for a seamless land-sea vertical datum in Taiwan

    NASA Astrophysics Data System (ADS)

    Yen-Ti, C.; Hwang, C.

    2017-12-01

    Conventional topographic and hydrographic mappings use two separate reference surfaces, called orthometric datum (TWVD2001 in Taiwan) and chart datum. In Taiwan, land elevations are heights tied to a leveling control network with its zero height at the mean sea surface of Keelung Harbor (realized by the height of Benchmark K999). Ocean depths are counted from the lowest tidal surface defined by tidal measurements near the sites of depth measurements. This paper usesa new method to construct a unified vertical datum for land elevations and ocean depths around Taiwan. First, we determine an optimal mean sea surface model (MSSHM) using refined offshore altimeter data. Then, the ellipsoidal heights of the mean sea levels at 36 tide gauges around Taiwan are determined using GPS measurements at their nearby benchmarks, and are then combined with the altimeter-derived MSSHM to generate a final MSSHM that has a smooth transition from land to sea. We also construct an improved ocean tide model to obtain various tidal surfaces. Using the latest land, shipborne, airborne and altimeter-derived gravity data, we construct a hybrid geoid model to define a vertical datum on land. The final MSSHM is the zero surface that defines ocean tidal heights and lowest tidal values in a ellipsoidal system that is fully consistent with the geodetic system of GNSS. The use of the MSSHM and the hybrid geoid model enables a seamless connection to combine or compare coastal land and sea elevations from a wide range of sources.

  2. A Lidar Point Cloud Based Procedure for Vertical Canopy Structure Analysis And 3D Single Tree Modelling in Forest

    PubMed Central

    Wang, Yunsheng; Weinacker, Holger; Koch, Barbara

    2008-01-01

    A procedure for both vertical canopy structure analysis and 3D single tree modelling based on Lidar point cloud is presented in this paper. The whole area of research is segmented into small study cells by a raster net. For each cell, a normalized point cloud whose point heights represent the absolute heights of the ground objects is generated from the original Lidar raw point cloud. The main tree canopy layers and the height ranges of the layers are detected according to a statistical analysis of the height distribution probability of the normalized raw points. For the 3D modelling of individual trees, individual trees are detected and delineated not only from the top canopy layer but also from the sub canopy layer. The normalized points are resampled into a local voxel space. A series of horizontal 2D projection images at the different height levels are then generated respect to the voxel space. Tree crown regions are detected from the projection images. Individual trees are then extracted by means of a pre-order forest traversal process through all the tree crown regions at the different height levels. Finally, 3D tree crown models of the extracted individual trees are reconstructed. With further analyses on the 3D models of individual tree crowns, important parameters such as crown height range, crown volume and crown contours at the different height levels can be derived. PMID:27879916

  3. New Measurements of Aerosol Vertical Structure from Space Using the NASA Geoscience Laser Altimeter System (GLAS): Applications for Aerosol Transport Models

    NASA Technical Reports Server (NTRS)

    Welton, Ellsworth J.; Ginoux, Paul; Colarco, Peter; Chin, Mian; Spinhirne, James D.; Palm, Steven P.; Hlavka, Dennis; Hart, William

    2003-01-01

    In the past, satellite measurements of aerosols have only been possible using passive sensors. Analysis of passive satellite data has lead to an improved understanding of aerosol properties, spatial distribution, and their effect on the earth s climate. However, direct measurement of aerosol vertical distribution has not been possible using only the passive data. Knowledge of aerosol vertical distribution is important to correctly assess the impact of aerosol absorption, for certain atmospheric correction procedures, and to help constrain height profiles in aerosol transport models. On January 12,2003 NASA launched the first satellite-based lidar, the Geoscience Laser Altimeter System (GLAS), onboard the ICESat spacecraft. GLAS is both an altimeter and an atmospheric lidar, and obtains direct measurements of aerosol and cloud heights. Here we show an overview of GLAS, provide an update of its current status, and discuss how GUS data will be useful for modeling efforts. In particular, a strategy of using GLAS to characterize the height profile of dust plumes over source regions will be presented, along with initial results. Such information can be used to validate and improve output from aerosol transport models. Aerosol height profile comparisons between GLAS and transport models will be shown for regions downwind of aerosol sources. We will also discuss the feasibility of assimilating GLAS profiles into the models in order to improve their output,

  4. New Measurements of Aerosol Vertical Structure from Space using the NASA Geoscience Laser Altimeter System (GLAS): Applications for Aerosol Transport Models

    NASA Technical Reports Server (NTRS)

    Welton, E. J.; Spinhime, J.; Palm, S.; Hlavka, D.; Hart, W.; Ginoux, P.; Chin, M.; Colarco, P.

    2004-01-01

    In the past, satellite measurements of aerosols have only been possible using passive sensors. Analysis of passive satellite data has lead to an improved understanding of aerosol properties, spatial distribution, and their effect on the earth,s climate. However, direct measurement of aerosol vertical distribution has not been possible using only the passive data. Knowledge of aerosol vertical distribution is important to correctly assess the impact of aerosol absorption, for certain atmospheric correction procedures, and to help constrain height profiles in aerosol transport models. On January 12,2003 NASA launched the first satellite-based lidar, the Geoscience Laser Altimeter System (GLAS), onboard the ICESat spacecraft. GLAS is both an altimeter and an atmospheric lidar, and obtains direct measurements of aerosol and cloud heights. Here we show an overview of GLAS, provide an update of its current status, and discuss how GLAS data will be useful for modeling efforts. In particular, a strategy of using GLAS to characterize the height profile of dust plumes over source regions will be presented, along with initial results. Such information can be used to validate and improve output from aerosol transport models. Aerosol height profile comparisons between GLAS and transport models will be shown for regions downwind of aerosol sources. We will also discuss the feasibility of assimilating GLAS profiles into the models in order to improve their output.

  5. The vertical pattern of microwave radiation around BTS (Base Transceiver Station) antennae in Hashtgerd township.

    PubMed

    Nasseri, Simin; Monazzam, Mohammadreza; Beheshti, Meisam; Zare, Sajad; Mahvi, Amirhosein

    2013-12-20

    New environmental pollutants interfere with the environment and human life along with technology development. One of these pollutants is electromagnetic field. This study determines the vertical microwave radiation pattern of different types of Base Transceiver Station (BTS) antennae in the Hashtgerd city as the capital of Savojbolagh County, Alborz Province of Iran. The basic data including the geographical location of the BTS antennae in the city, brand, operator type, installation and its height was collected from radio communication office, and then the measurements were carried out according to IEEE STD 95. 1 by the SPECTRAN 4060. The statistical analyses were carried out by SPSS16 using Kolmogorov Smirnov test and multiple regression method. Results indicated that in both operators of Irancell and Hamrah-e-Aval (First Operator), the power density rose with an increase in measurement height or decrease in the vertical distance of broadcaster antenna. With mix model test, a significant statistical relationship was observed between measurement height and the average power density in both types of the operators. With increasing measuring height, power density increased in both operators. The study showed installing antennae in a crowded area needs more care because of higher radiation emission. More rigid surfaces and mobile users are two important factors in crowded area that can increase wave density and hence raise public microwave exposure.

  6. Greater effect of increasing shrub height on winter versus summer soil temperature

    NASA Astrophysics Data System (ADS)

    Paradis, Mélissa; Lévesque, Esther; Boudreau, Stéphane

    2016-08-01

    Shrub expansion is increasingly observed in arctic and subarctic environments. The development of shrub structure may significantly impact the abiotic environment at the local scale. Our objective was to reconstruct the development of the vertical structure of Betula glandulosa Michx. and to evaluate its effects on winter and summer soil temperature and on snow depth. Stratified sampling of the shrub revealed that shrub biomass distribution followed a similar pattern in stands of contrasting heights. Woody biomass was maximal in the lower stratum and relatively stable in the intermediate strata, while the foliar biomass tracked the vertical development of the shrub structure. Dendrochronological analysis revealed that shrub stands are relatively young; most of the dominant stems started their development after 1990. Shrub height was positively associated with both the dominant stem age and its vertical growth rate. Temperature differences among sites were greater during winter (ca 10 °C) than during summer (ca 2 °C), while the sum of freezing degree-days varied from 680 °C to 2125 °C. Shrub height was the most plausible variable explaining snow depth, winter ground level temperature and the sum of freezing degree-days. However, woody biomass in the 30-40 cm strata best explained summer ground level temperature. Our results suggest that the development of a shrub structure will have far-reaching consequences on the abiotic environment of subarctic ecosystems.

  7. Comparison and analysis of three different methods to evaluate vertical jump height.

    PubMed

    Bui, Hung Tien; Farinas, Marie-Isabelle; Fortin, Anne-Marie; Comtois, Alain-Steve; Leone, Mario

    2015-05-01

    The purpose of this study was to compare three methods to assess vertical jump height, to determine their limitations and to propose solutions to mitigate their effects. The chosen methods were the contact mat, the optical system and the Sargent jump. The testing environment was designed such that all three systems simultaneously measured the vertical jump height. A total of 41 kinesiology students (18 women, 23 men, mean age 23·2 ± 4·5 years) participated in this study. Data show that the contact mat and the optical system essentially provide similar results (P = 0·912) and that the correlation coefficient between the two systems was 0·972 (r(2)  = 0·944). However, it was found that the Sargent jump has a tendency to overestimate the height, providing a measurement that is significantly different from the other two methods as the jumps are higher than 30·64 cm (P = 0·044). Through the design of the experiment, several sources of errors were identified and mathematically modelled. These sources include optical sensor placement, flat-footed landing and hip/knee bend. Whenever possible, the errors were quantified and solutions were proposed. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  8. The vertical pattern of microwave radiation around BTS (Base Transceiver Station) antennae in Hashtgerd township

    PubMed Central

    2013-01-01

    New environmental pollutants interfere with the environment and human life along with technology development. One of these pollutants is electromagnetic field. This study determines the vertical microwave radiation pattern of different types of Base Transceiver Station (BTS) antennae in the Hashtgerd city as the capital of Savojbolagh County, Alborz Province of Iran. The basic data including the geographical location of the BTS antennae in the city, brand, operator type, installation and its height was collected from radio communication office, and then the measurements were carried out according to IEEE STD 95. 1 by the SPECTRAN 4060. The statistical analyses were carried out by SPSS16 using Kolmogorov Smirnov test and multiple regression method. Results indicated that in both operators of Irancell and Hamrah-e-Aval (First Operator), the power density rose with an increase in measurement height or decrease in the vertical distance of broadcaster antenna. With mix model test, a significant statistical relationship was observed between measurement height and the average power density in both types of the operators. With increasing measuring height, power density increased in both operators. The study showed installing antennae in a crowded area needs more care because of higher radiation emission. More rigid surfaces and mobile users are two important factors in crowded area that can increase wave density and hence raise public microwave exposure. PMID:24359870

  9. How long bones grow children: Mechanistic paths to variation in human height growth.

    PubMed

    Lampl, Michelle; Schoen, Meriah

    2017-03-01

    Eveleth and Tanner's descriptive documentation of worldwide variability in human growth provided evidence of the interaction between genetics and environment during development that has been foundational to the science of human growth. There remains a need, however, to describe the mechanistic foundations of variability in human height growth patterns. A review of research documenting cellular activities at the endochondral growth plate aims to show how the unique microenvironment and cell functions during the sequential phases of the chondrocyte lifecycle affect long bone elongation, a fundamental source of height growth. There are critical junctures within the chondrocytic differentiation cascade at which environmental influences are integrated and have the ability to influence progression to the hypertrophic chondrocyte phase, the primary driver of long bone elongation. Phenotypic differences in height growth patterns reflect variability in amplitude and frequency of discretely timed hypertrophic cellular expansion events, the cellular basis of saltation and stasis growth biology. Final height is a summary of the dynamic processes carried out by the growth plate cellular machinery. As these cell-level mechanisms unfold in an individual, time-specific manner, there are many critical points at which a genetic growth program can be enhanced or perturbed. Recognizing both the complexity and fluidity of this adaptive system questions the likelihood of a single, optimal growth pattern and instead identifies a larger bandwidth of saltatory frequencies for "normal" growth. Further inquiry into mechanistic sources of variability acting at critical organizational points of chondrogenesis can provide new opportunities for growth interventions. © 2017 Wiley Periodicals, Inc.

  10. Efficacy of short-term growth hormone treatment in prepubertal children with idiopathic short stature.

    PubMed

    Kim, Ho-Seong; Yang, Sei Won; Yoo, Han-Wook; Suh, Byung Kyu; Ko, Cheol Woo; Chung, Woo Yeong; Lee, Kee Hyoung; Hwang, Jin Soon; Ji, Hyi-Jeong; Ahn, Hyunji; Kim, Duk Hee

    2014-01-01

    It has been reported that daily recombinant human growth hormone (GH) treatment showed beneficial effects on growth in prepubertal children with idiopathic short stature (ISS). The present study aimed to validate the GH (Eutropin®) effect on growth promotion and safety after short-term GH treatment. This study was an open-label, multicenter, interventional study conducted at nine university hospitals in Korea between 2008 and 2009. Thirty six prepubertal children with ISS were enrolled in this study to receive 6-month GH treatment. Yearly growth rate, height standard deviation score (SDS), and adverse events were investigated during treatment. After 26 weeks of GH treatment, the height velocity significantly increased by 6.36±3.36 cm/year (p<0.001). The lower end of one-sided 95% confidence interval was 5.22 cm/year, far greater than the predefined effect size. The gain in height SDS at week 26 was 0.57±0.27 (p<0.0001). Bone age significantly increased after GH treatment, however, bone maturation rate (bone age for chronological age) showed limited advancement. This 26-week GH treatment was effective in increasing serum levels of insulin-like growth factor (IGF)-I and IGF binding protein (IGFBP)-3 from baseline (p<0.0001). Eutropin was well tolerated and there were no withdrawals due to adverse events. No clinically significant changes in laboratory values were observed. This 6-month daily GH treatment in children with ISS demonstrated increased height velocity, improved height SDS, and increased IGF-I and IGFBP-3 levels with a favorable safety profile.

  11. Accounting for body size deviations when reporting bone mineral density variables in children.

    PubMed

    Webber, C E; Sala, A; Barr, R D

    2009-01-01

    In a child, bone mineral density (BMD) may differ from an age-expected normal value, not only because of the presence of disease, but also because of deviations of height or weight from population averages. Appropriate adjustment for body size deviations simplifies interpretation of BMD measurements. For children, a bone mineral density (BMD) measurement is normally expressed as a Z score. Interpretation is complicated when weight or height distinctly differ from age-matched children. We develop a procedure to allow for the influence of body size deviations upon measured BMD. We examined the relation between body size deviation and spine, hip and whole body BMD deviation in 179 normal children (91 girls). Expressions were developed that allowed derivation of an expected BMD based on age, gender and body size deviation. The difference between measured and expected BMD was expressed as a HAW score (Height-, Age-, Weight-adjusted score). In a second independent sample of 26 normal children (14 girls), measured spine, total femur and whole body BMD all fell within the same single normal range after accounting for age, gender and body size deviations. When traditional Z scores and HAW scores were compared in 154 children, 17.5% showed differences of more than 1 unit and such differences were associated with height and weight deviations. For almost 1 in 5 children, body size deviations influence BMD to an extent that could alter clinical management.

  12. Recombinant human bone morphogenetic protein 2 outcomes for maxillary sinus floor augmentation: a systematic review and meta-analysis.

    PubMed

    Lin, Guo-Hao; Lim, Glendale; Chan, Hsun-Liang; Giannobile, William V; Wang, Hom-Lay

    2016-11-01

    To study the effect of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on sinus volumetric and histometric changes after sinus floor augmentation compared to a conventional approach of non-biologic bone grafting materials. An electronic search of 4 databases (January 1990-February 2015), including PubMed/MEDLINE, EMBASE, Web of Science and Cochrane Central, and a hand search of peer-reviewed journals for relevant articles were performed. Human clinical trials with data on comparison of sinus volumetric and/or histometric outcomes with and without the use of rhBMP-2 in sinus grafting procedures, with ≥10 augmentation sites in each study group, and with a follow-up period of at least 6 months, were included. Random-effects meta-analyses were performed to analyze weighted mean difference (WMD) and confidence interval (CI) for the recorded variables according to PRISMA guidelines. Six randomized controlled trials (RCTs) were included. The results of the meta-analyses showed that the WMD of vertical bone height gain was -0.14 mm (95% CI = -1.91 to 1.62 mm, P = 0.87), the WMD of bone density was -142.42 mg/cm 3 (95% CI = -310.62-25.78 mg/cm 3 , P = 0.10), the WMD of the percentage of vital bone was -4.59% (95% CI = -11.73-2.56%, P = 0.21), and the WMD of the percentage of residual bone grafting materials was -9.90% (95% CI = -26.38-6.58%, P = 0.21). The comparison of implant survival rate presented an overall risk ratio of 1.00 (95% CI = 0.94-1.07). The two approaches (conventional bone grafting compared to BMPs) demonstrated comparable effectiveness for both clinical and histomorphometric measures. This systematic review revealed that the use of rhBMP-2 in maxillary sinus floor augmentation achieved similar clinical and histometric outcomes when compared to conventional sinus grafting procedures after a healing period of 6-9 months. However, previous studies showed the morbidity and other patient-reported outcomes were improved in rhBMP-2 approaches as compared to bone autograft procedures (both intraoral and extraoral bone harvesting because no donor site is required). Long-term studies are required to determine the cost-benefit of sinus floor augmentation procedures for patients requiring implant reconstruction. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Improvement of vertical profiles of raindrop size distribution from micro rain radar using 2D video disdrometer measurements

    NASA Astrophysics Data System (ADS)

    Adirosi, E.; Baldini, L.; Roberto, N.; Gatlin, P.; Tokay, A.

    2016-03-01

    A measurement scheme aimed at investigating precipitation properties based on collocated disdrometer and profiling instruments is used in many experimental campaigns. Raindrop size distribution (RSD) estimated by disdrometer is referred to the ground level; the collocated profiling instrument is supposed to provide complementary estimation at different heights of the precipitation column above the instruments. As part of the Special Observation Period 1 of the HyMeX (Hydrological Cycle in the Mediterranean Experiment) project, conducted between 5 September and 6 November 2012, a K-band vertically pointing micro rain radar (MRR) and a 2D video disdrometer (2DVD) were installed close to each other at a site in the historic center of Rome (Italy). The raindrop size distributions collected by 2D video disdrometer are considered to be fairly accurate within the typical sizes of drops. Vertical profiles of raindrop sizes up to 1085 m are estimated from the Doppler spectra measured by the micro rain radar with a height resolution of 35 m. Several issues related to vertical winds, attenuation correction, Doppler spectra aliasing, and range-Doppler ambiguity limit the performance of MRR in heavy precipitation or in convection, conditions that frequently occur in late summer or in autumn in Mediterranean regions. In this paper, MRR Doppler spectra are reprocessed, exploiting the 2DVD measurements at ground to estimate the effects of vertical winds at 105 m (the most reliable MRR lower height), in order to provide a better estimation of vertical profiles of raindrop size distribution from MRR spectra. Results show that the reprocessing procedure leads to a better agreement between the reflectivity computed at 105 m from the reprocessed MRR spectra and that obtained from the 2DVD data. Finally, vertical profiles of MRR-estimated RSDs and their relevant moments (namely median volume diameter and reflectivity) are presented and discussed in order to investigate the microstructure of rain both in stratiform and convective conditions.

  14. Perceptual simulation in gender categorization: associations between gender, vertical height, and spatial size.

    PubMed

    Zhang, Xiaobin; Li, Qiong; Eskine, Kendall J; Zuo, Bin

    2014-01-01

    The current studies extend perceptual symbol systems theory to the processing of gender categorization by revealing that gender categorization recruits perceptual simulations of spatial height and size dimensions. In study 1, categorization of male faces were faster when the faces were in the "up" (i.e., higher on the vertical axis) rather than the "down" (i.e., lower on the vertical axis) position and vice versa for female face categorization. Study 2 found that responses to male names depicted in larger font were faster than male names depicted in smaller font, whereas opposite response patterns were given for female names. Study 3 confirmed that the effect in Study 2 was not due to metaphoric relationships between gender and social power. Together, these findings suggest that representation of gender (social categorization) also involves processes of perceptual simulation.

  15. Observation of two coupled Faraday waves in a vertically vibrating Hele-Shaw cell with one of them oscillating horizontally

    NASA Astrophysics Data System (ADS)

    Li, Xiaochen; Li, Xiaoming; Liao, Shijun

    2018-01-01

    A system of two coupled Faraday waves is experimentally observed at the two interfaces of the three layers of fluids (air, pure ethanol, and silicon oil) in a covered Hele-Shaw cell with periodic vertical vibration. Both the upper and lower Faraday waves are subharmonic, but they coexist in different forms: the upper one vibrates vertically, while the crests of the lower one oscillate horizontally with unchanged wave height, and the troughs of the lower one usually remain in the same place (relative to the basin). Besides, they are strongly coupled: the wave height of the lower Faraday waves is either a linear function (when forcing frequency is fixed) or a parabolic function (when acceleration amplitude is fixed) of that of the upper one with a same wavelength.

  16. Vertical distributions of aerosols under different weather conditions: Analysis of in-situ aircraft measurements in Beijing, China

    NASA Astrophysics Data System (ADS)

    Zhang, Qiang; Ma, XinCheng; Tie, Xuexi; Huang, Mengyu; Zhao, Chunsheng

    In this study, aerosol vertical distributions of 17 in-situ aircraft measurements during 2005 and 2006 springs are analyzed. The 17 flights are carefully selected to exclude dust events, and the analyses are focused on the vertical distributions of aerosol particles associated with anthropogenic activities. The results show that the vertical distributions of aerosol particles are strongly affected by weather and meteorological conditions, and 3 different types of aerosol vertical distributions corresponding to different weather systems are defined in this study. The measurement with a flat vertical gradient and low surface aerosol concentrations is defined as type-1; a gradual decrease of aerosols with altitudes and modest surface aerosol concentrations is defined as type-2; a sharp vertical gradient (aerosols being strongly depressed in the PBL) with high surface aerosol concentrations is defined as type-3. The weather conditions corresponding to the 3 different aerosol types are high pressure, between two high pressures, and low pressure systems (frontal inversions), respectively. The vertical mixing and horizontal transport for the 3 different vertical distributions are analyzed. Under the type-1 condition, the vertical mixing and horizontal transport were rapid, leading to strong dilution of aerosols in both vertical and horizontal directions. As a result, the aerosol concentrations in PBL (planetary boundary layer) were very low, and the vertical distribution was flat. Under the type-2 condition, the vertical mixing was strong and there was no strong barrier at the PBL height. The horizontal transport (wind flux) was modest. As a result, the aerosol concentrations were gradually reduced with altitude, with modest surface aerosol concentrations. Under the type-3 condition, there was a cold front near the region. As a result, a frontal inversion associated with weak vertical mixing appeared at the top of the inversion layer, forming a very strong barrier to prevent aerosol particles being exchanged from the PBL height to the free troposphere. As a result, the aerosol particles were strongly depressed in the PBL height, producing high surface aerosol concentrations. The measured vertical aerosol distributions have important implications for studying the effects of aerosols on photochemistry. The J[O 3] values are reduced by 11%, 48%, and 50%, under the type-1, type-2, and type-3 conditions, respectively. This result reveals that atmospheric oxidant capacity (OH concentrations) is modestly reduced under the type-1 condition, but is significantly reduced under the type-2 and type-3 conditions. This result also suggests that the effect of aerosol particles on surface solar flux is an integrated column effect, and detailed vertical distributions of aerosol particles are very important for assessing the impacts of aerosol on photochemistry.

  17. Light drives vertical gradients of leaf morphology in a sugar maple (Acer saccharum) forest.

    PubMed

    Coble, Adam P; Cavaleri, Molly A

    2014-02-01

    Leaf mass per area (LMA, g m(-2)) is an essential trait for modeling canopy function due to its strong association with photosynthesis, respiration and leaf nitrogen. Leaf mass per area, which is influenced by both leaf thickness and density (LMA = thickness × density), generally increases from the bottom to the top of tree canopies, yet the mechanisms behind this universal pattern are not yet resolved. For decades, the light environment was assumed to be the most influential driver of within-canopy variation in LMA, yet recent evidence has shown hydrostatic gradients to be more important in upper canopy positions, especially in tall evergreen trees in temperate and tropical forests. The aim of this study was to disentangle the importance of various environmental drivers on vertical LMA gradients in a mature sugar maple (Acer saccharum Marshall) forest. We compared LMA, leaf density and leaf thickness relationships with height, light and predawn leaf water potential (ΨPre) within a closed and an exposed canopy to assess leaf morphological traits at similar heights but different light conditions. Contrary to our expectations and recent findings in the literature, we found strong evidence that light was the primary driver of vertical gradients in leaf morphology. At similar heights (13-23 m), LMA was greater within the exposed canopy than the closed canopy, and light had a stronger influence over LMA compared with ΨPre. Light also had a stronger influence over both leaf thickness and density compared with ΨPre; however, the increase in LMA within both canopy types was primarily due to increasing leaf thickness with increasing light availability. This study provides strong evidence that canopy structure and crown exposure, in addition to height, should be considered as a parameter for determining vertical patterns in LMA and modeling canopy function.

  18. Sinus Floor Augmentation Using Straumann® BoneCeramic™ and Bio-Oss® in a Split Mouth Design and Later Placement of Implants: A 5-Year Report from a Longitudinal Study.

    PubMed

    Mordenfeld, Arne; Lindgren, Christer; Hallman, Mats

    2016-10-01

    Straumann® BoneCeramic™ is a synthetic biphasic calcium phosphate (BCP) aimed for sinus floor augmentation. Long-term follow-up of implants placed in BCP after sinus augmentation is still missing. The primary aim of the study was to compare survival rates and marginal bone loss of Straumann SLActive implants placed in either BCP (test) or Bio-Oss® (DBB) (control) after sinus floor augmentation. The secondary aim was to calculate graft sinus height at different time points. Bilateral sinus floor augmentation was performed in a split mouth model. Eleven patients (mean age 67 years) received 100% BCP on one side and 100% DBB on the contralateral side. After 8 months of graft healing, 62 Straumann SLActive implants were placed. After 5 years of functional loading (6 years after augmentation) of implants, marginal bone levels and grafted sinus height were measured, and implant survival and success rates were calculated. After 5 years of loading, all prosthetic constructions were in function although two implants were lost in each grafting material. The overall implant survival rate was 93.5% (91.7% for BCP, 91.3% for DBB, and 100% for residual bone). The success rates were 83.3% and 91.3% for BCP and DBB, respectively. There was no statistically significant difference in mean marginal bone level after 5 years between BCP (1.4 ± 1.2 mm) and DBB (1.0 ± 0.7 mm). Graft height reduction (GHR) after 6 years was limited to 6.6% for BCP and 5.8% for DBB. In this limited RCT study, the choice of biomaterial used for sinus floor augmentation did not seem to have any impact on survival rates and marginal bone level of the placed implants after 5 years of functional loading and GHR was minimal. © 2015 Wiley Periodicals, Inc.

  19. Toll-Like Receptor 4 Gene Polymorphism C1196T in Polish Women with Postmenopausal Osteoporosis - Preliminary Investigation.

    PubMed

    Kaleta, Beata; Walicka, Magdalena; Sawicka, Ada; Bogołowska-Stieblich, Agata; Górski, Andrzej; Łukaszkiewicz, Jacek; Marcinowska-Suchowierska, Ewa

    2015-01-01

    Postmenopausal osteoporosis is a systemic bone disease characterized by low bone mass after menopause. Bone remodeling is regulated by a number of factors, including the immune system. Toll-like receptors 4 (TLR4) are expressed on bone cells and modify the immune response. TLR4 gene polymorphism may take part in the development of chronic inflammation in women after menopause, which is the cause of severe bone resorption. To examine the frequency of TLR4 C1196T genotypes in postmenopausal osteoporotic and non-osteoporotic Polish women and to investigate the possible relationship between C1196T polymorphism, bone mineral density (BMD) and the incidence of osteoporotic fractures in this group of patients. The study involved 40 postmenopausal women with osteoporosis and 63 healthy postmenopausal non-osteoporotic women. BMD measurements were performed by dual-energy X-ray absorptiometry. DNA was extracted from peripheral blood. Genotyping was performed by real-time PCR using LightSNiP tests with SimpleProbe probes. Melting curve analysis of PCR amplicons enabled the identification of individual C1196T genotypes. C1196T genotype frequencies in the osteoporotic group were 88% for CC and 12% for CT. In the control group, respectively 86% and 14%. We did not observe the TT genotype. There was no association of C1196T genotypes and BMD nor the incidence of fractures but there was a correlation between genotypes and body height (p=0.035, r=0.415). Homozygous subjects for the C-allele had a lower body height with respect to heterozygous subjects. It is unlikely that TLR4 C1196T polymorphism is related to bone mineral density and fracture incidence in Polish osteoporotic women after menopause. However, our data suggests that the C allele may be associated with lower body height in this group. Due to the small number of participants, our observations should be considered as preliminary. Larger studies are needed to confirm our findings.

  20. Growth hormone therapy alone or in combination with gonadotropin-releasing hormone analog therapy to improve the height deficit in children with congenital adrenal hyperplasia.

    PubMed

    Quintos, J B; Vogiatzi, M G; Harbison, M D; New, M I

    2001-04-01

    Short stature in the adult patient with congenital adrenal hyperplasia (CAH) is commonly seen, even among patients in excellent adrenal control during childhood and puberty. In this study we examine the effect of GH therapy on height prediction in children with both CAH and compromised height prediction. Leuprolide acetate, a GnRH analog (GnRHa), was given to patients with evidence of early puberty. GH (n = 12) or the combination of GH and GnRHa (n = 8) was administered to 20 patients with CAH while they continued therapy with glucocorticoids. Each patient in the treatment group was matched according to age, sex, bone age, puberty, and type of CAH with another CAH patient treated only with glucocorticoid replacement. The match was made at the start of GH treatment. Of the 20 patients, 12 have completed 2 yr of therapy. After 1 yr of GH or combination GH and GnRHa therapy, the mean growth rate increased from 5 +/- 1.9 to 7.8 +/- 1.6 cm/yr vs. 5.4 +/- 1.7 to 5 +/- 2 cm/yr in the group not receiving GH (P < 0.0001). During the second year of treatment, the mean growth rate was 6 +/- 1.6 vs. 4.2 +/- 2.1 cm/yr in the group not receiving GH (P < 0.001). The height SD score for chronological age in the treatment group at the end of 1 and 2 yr of treatment improved significantly more than the nontreatment group (P < 0.01). A similar improvement in the height SD score for bone age was found in the treatment group after 1 (-1.4 +/- 0.9 vs. -1.7 +/- 0.9; P < 0.0001) and 2 yr of therapy (-0.67 +/- 0.68 vs. -1.7 +/- 1.2; P < 0.0004). The mean predicted adult height improved from 159 +/- 11 (baseline) to 170 +/- 7.5 cm (after 2 yr of therapy) closely approximating target height (173 +/- 8 cm). All patients continued the hydrocortisone treatment. In patients with CAH and compromised height prediction, treatment with GH or the combination of GH and GnRHa results in an improvement of growth rate and height prediction and a reduction in height deficit for bone age.

  1. Dynamics of a thermally driven film climbing the outside of a vertical cylinder

    NASA Astrophysics Data System (ADS)

    Smolka, Linda B.

    2017-10-01

    The dynamics of a film climbing the outside of a vertical cylinder under the competing effects of a thermally driven surface tension gradient and gravity is examined through numerical simulations of a thin-film model for the film height. The model, including boundary conditions, depends on three parameters, the scaled cylinder radius R ̂, the upstream film height h∞, and the downstream precursor film thickness b , and reduces to the model for Marangoni driven film climbing a vertical plate in the limit R ̂→∞ . The axisymmetric advancing front displays dynamics similar to that found along a vertical plate where, depending on h∞, the film forms a single Lax shock, an undercompressive double shock, or a rarefaction-undercompressive shock. A linear stability analysis of the Lax shock reveals the number of fingers that form along the contact line increases linearly with cylinder circumference while no fingers form for sufficiently small cylinders (below R ̂≈1.15 when b =0.1 ). The substrate curvature controls the height of the Lax shock, bounds on h∞ that define the three distinct solutions, and the maximum growth rate of contact line perturbations to the Lax shock when R ̂=O (1 ) , whereas the three solutions and the stability of the Lax shock converge to the behavior one observes on a vertical plate when R ̂≥O (10 ) . An energy analysis reveals that the azimuthal curvatures of the base state and perturbation, which arise from the annular geometry of the film, promote instability of the advancing contact line.

  2. Dynamics of a thermally driven film climbing the outside of a vertical cylinder.

    PubMed

    Smolka, Linda B

    2017-10-01

    The dynamics of a film climbing the outside of a vertical cylinder under the competing effects of a thermally driven surface tension gradient and gravity is examined through numerical simulations of a thin-film model for the film height. The model, including boundary conditions, depends on three parameters, the scaled cylinder radius R[over ̂], the upstream film height h_{∞}, and the downstream precursor film thickness b, and reduces to the model for Marangoni driven film climbing a vertical plate in the limit R[over ̂]→∞. The axisymmetric advancing front displays dynamics similar to that found along a vertical plate where, depending on h_{∞}, the film forms a single Lax shock, an undercompressive double shock, or a rarefaction-undercompressive shock. A linear stability analysis of the Lax shock reveals the number of fingers that form along the contact line increases linearly with cylinder circumference while no fingers form for sufficiently small cylinders (below R[over ̂]≈1.15 when b=0.1). The substrate curvature controls the height of the Lax shock, bounds on h_{∞} that define the three distinct solutions, and the maximum growth rate of contact line perturbations to the Lax shock when R[over ̂]=O(1), whereas the three solutions and the stability of the Lax shock converge to the behavior one observes on a vertical plate when R[over ̂]≥O(10). An energy analysis reveals that the azimuthal curvatures of the base state and perturbation, which arise from the annular geometry of the film, promote instability of the advancing contact line.

  3. The power of vertical geolocation of atmospheric profiles from GNSS radio occultation.

    PubMed

    Scherllin-Pirscher, Barbara; Steiner, Andrea K; Kirchengast, Gottfried; Schwärz, Marc; Leroy, Stephen S

    2017-02-16

    High-resolution measurements from Global Navigation Satellite System (GNSS) radio occultation (RO) provide atmospheric profiles with independent information on altitude and pressure. This unique property is of crucial advantage when analyzing atmospheric characteristics that require joint knowledge of altitude and pressure or other thermodynamic atmospheric variables. Here we introduce and demonstrate the utility of this independent information from RO and discuss the computation, uncertainty, and use of RO atmospheric profiles on isohypsic coordinates-mean sea level altitude and geopotential height-as well as on thermodynamic coordinates (pressure and potential temperature). Using geopotential height as vertical grid, we give information on errors of RO-derived temperature, pressure, and potential temperature profiles and provide an empirical error model which accounts for seasonal and latitudinal variations. The observational uncertainty of individual temperature/pressure/potential temperature profiles is about 0.7 K/0.15%/1.4 K in the tropopause region. It gradually increases into the stratosphere and decreases toward the lower troposphere. This decrease is due to the increasing influence of background information. The total climatological error of mean atmospheric fields is, in general, dominated by the systematic error component. We use sampling error-corrected climatological fields to demonstrate the power of having different and accurate vertical coordinates available. As examples we analyze characteristics of the location of the tropopause for geopotential height, pressure, and potential temperature coordinates as well as seasonal variations of the midlatitude jet stream core. This highlights the broad applicability of RO and the utility of its versatile vertical geolocation for investigating the vertical structure of the troposphere and stratosphere.

  4. Reducing gravity takes the bounce out of running.

    PubMed

    Polet, Delyle T; Schroeder, Ryan T; Bertram, John E A

    2018-02-13

    In gravity below Earth-normal, a person should be able to take higher leaps in running. We asked 10 subjects to run on a treadmill in five levels of simulated reduced gravity and optically tracked centre-of-mass kinematics. Subjects consistently reduced ballistic height compared with running in normal gravity. We explain this trend by considering the vertical take-off velocity (defined as maximum vertical velocity). Energetically optimal gaits should balance the energetic costs of ground-contact collisions (favouring lower take-off velocity), and step frequency penalties such as leg swing work (favouring higher take-off velocity, but less so in reduced gravity). Measured vertical take-off velocity scaled with the square root of gravitational acceleration, following energetic optimality predictions and explaining why ballistic height decreases in lower gravity. The success of work-based costs in predicting this behaviour challenges the notion that gait adaptation in reduced gravity results from an unloading of the stance phase. Only the relationship between take-off velocity and swing cost changes in reduced gravity; the energetic cost of the down-to-up transition for a given vertical take-off velocity does not change with gravity. Because lower gravity allows an elongated swing phase for a given take-off velocity, the motor control system can relax the vertical momentum change in the stance phase, thus reducing ballistic height, without great energetic penalty to leg swing work. Although it may seem counterintuitive, using less 'bouncy' gaits in reduced gravity is a strategy to reduce energetic costs, to which humans seem extremely sensitive. © 2018. Published by The Company of Biologists Ltd.

  5. Vertical augmentation of the posterior atrophic mandible by interpositional grafts in a split-mouth design: a human tomography evaluation pilot study.

    PubMed

    Domingues, Eduardo Pinheiro; Ribeiro, Rafael Fernandes; Horta, Martinho Campolina Rebello; Manzi, Flávio Ricardo; Côsso, Maurício Greco; Zenóbio, Elton Gonçalves

    2017-10-01

    Using computed tomography, to compare vertical and volumetric bone augmentation after interposition grafting with bovine bone mineral matrix (GEISTLICH BIO-OSS ® ) or hydroxyapatite/tricalcium phosphate (STRAUMANN ® BONECERAMIC) for atrophic posterior mandible reconstruction through segmental osteotomy. Seven patients received interposition grafts in the posterior mandible for implant rehabilitation. The computed tomography cone beam images were analysed with OsiriX Imaging Software 6.5 (Pixmeo Geneva, Switzerland) in the pre-surgical period (T0), at 15 days post-surgery (T1) and at 180 days post-surgery (T2). The tomographic analysis was performed by a single trained and calibrated radiologist. Descriptive statistics and nonparametric methods were used to analyse the data. There was a significant difference in vertical and volume augmentation with both biomaterials using the technique (P < 0.05). There were no significant differences (P > 0.05) in volume change of the graft, bone volume augmentation, or augmentation of the maximum linear vertical distance between the two analysed biomaterials. The GEISTLICH BIO-OSS ® and STRAUMANN ® BONECERAMIC interposition grafts exhibited similar and sufficient dimensional stability and volume gain for short implants in the atrophic posterior mandible. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Vertical ridge augmentation using an equine bone and collagen block infused with recombinant human platelet-derived growth factor-BB: a randomized single-masked histologic study in non-human primates.

    PubMed

    Nevins, Myron; Al Hezaimi, Khalid; Schupbach, Peter; Karimbux, Nadeem; Kim, David M

    2012-07-01

    This study tests the effectiveness of hydroxyapatite and collagen bone blocks of equine origin (eHAC), infused with recombinant human platelet-derived growth factor-BB (rhPDGF-BB), to augment localized posterior mandibular defects in non-human primates (Papio hamadryas). Bilateral critical-sized defects simulating severe atrophy were created at the time of the posterior teeth extraction. Test and control blocks (without growth factor) were randomly grafted into the respective sites in each non-human primate. All sites exhibited vertical ridge augmentation, with physiologic hard- and soft-tissue integration of the blocks when clinical and histologic examinations were done at 4 months after the vertical ridge augmentation procedure. There was a clear, although non-significant, tendency to increased regeneration in the test sites. As in the first two preclinical studies in this series using canines, experimental eHAC blocks infused with rhPDGF-BB proved to be a predictable and technically viable method to predictably regenerate bone and soft tissue in critical-sized defects. This investigation supplies additional evidence that eHAC blocks infused with rhPDGF-BB growth factor is a predictable and technically feasible option for vertical augmentation of severely resorbed ridges.

  7. Spatial Representation of Pitch Height: The SMARC Effect

    ERIC Educational Resources Information Center

    Rusconi, Elena; Kwan, Bonnie; Giordano, Bruno L.; Umilta, Carlo; Butterworth, Brian

    2006-01-01

    Through the preferential pairing of response positions to pitch, here we show that the internal representation of pitch height is spatial in nature and affects performance, especially in musically trained participants, when response alternatives are either vertically or horizontally aligned. The finding that our cognitive system maps pitch height…

  8. 46 CFR 45.69 - Correction for bow height.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... least 15 percent of the length of the vessel measured from the forward perpendicular. (c) Where the bow... point at least 0.06 L abaft the forward perpendicular. (d) Vessels which, to suit exceptional... consideration by the Commandant. (e) The bow height is defined as the vertical distance at the forward...

  9. 46 CFR 45.69 - Correction for bow height.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... least 15 percent of the length of the vessel measured from the forward perpendicular. (c) Where the bow... point at least 0.06 L abaft the forward perpendicular. (d) Vessels which, to suit exceptional... consideration by the Commandant. (e) The bow height is defined as the vertical distance at the forward...

  10. 36 CFR 1192.53 - Doorways.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... between each vehicle door at rest and the platform shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height under all normal passenger load conditions. Vertical alignment may be accomplished by vehicle air suspension or other suitable...

  11. 36 CFR 1192.53 - Doorways.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... between each vehicle door at rest and the platform shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height under all normal passenger load conditions. Vertical alignment may be accomplished by vehicle air suspension or other suitable...

  12. The Geoscience Laser Altimeter System (GLAS) for the ICESAT Mission

    NASA Technical Reports Server (NTRS)

    Abshire, James B.; Sun, Xiao-Li; Ketchum, Eleanor A.; Afzal, Robert S.; Millar, Pamela S.

    1999-01-01

    Accurate measurements of surface heights and atmospheric backscatter have been demonstrated with the SLA, MOLA and LITE space lidar. Recent MOLA measurements of the Mars surface have 40 cm resolution and have reduced the global uncertainty in Mars topography from a few km to approx. 10 m. GLAS is a next generation lidar being developed as part of NASA's Icesat Mission for Earth orbit . The GLAS design combines a 10 cm precision surface lidar with a sensitive dual wavelength cloud and aerosol lidar. GLAS will precisely measure the heights of the Earth's polar ice sheets, determine the height profiles of the Earth's land topography, and profile the vertical backscatter of clouds and aerosols on a global scale. GLAS will fly on a small dedicated spacecraft in a polar orbit at 598 km altitude with an inclination of 94 degrees. GLAS is scheduled to launch in summer 2001 and to operate continuously for a minimum of 3 years with a goal of 5 years. The primary mission for GLAS is to measure the seasonal and annual changes in the heights of the Greenland and Antarctic ice sheets. GLAS will measure the vertical distance to the ice sheet from orbit with 1064 nm pulses from a Nd:Yag laser at 40 Hz. Each 5 nsec wide laser pulse is used for a single range measurement. When over land GLAS will profile the heights of the topography and vegetation. The GLAS receiver uses a I m diameter telescope and a Si APD detector. The detector signal is sampled by an all digital receiver which records each surface echo waveform with I nsec resolution and a stored echo record lengths of either 200, 400, or 600 samples. Analysis of the echo waveforms within the instrument permits discrimination between cloud and surface echoes. Ground based echo analysis permits precise ranging, determining the roughness or slopes of the surface as well as the vertical distributions of vegetation illuminated by the laser, Errors in knowledge of the laser beam pointing angle can bias height measurements of sloped surfaces. For surfaces with 2 deg. slopes, knowledge of pointing angle of the beam centroid to about 8 urad is required to achieve 10 cm height accuracy. GLAS uses a stellar reference system (SRS) to determine the pointing angle of each laser firing relative to inertial space. The SRS uses a high precision star camera oriented toward local zenith whose measurements are combined with a gyroscope to determine the inertial orientation of the SRS optical bench. The far field pattern of each laser pulse is measured with a laser reference system (LRS). Optically measuring each laser far field pattern relative to the star camera and gyroscope permits the angular offsets of each laser pulse to be determined. GLAS will also determine the vertical distributions of clouds and aerosols by measuring atmospheric backscatter profiles at both 1064 and 532 nm. The 1064 nm measurements use an analog detector and profile the height and vertical structure of thicker clouds. Measurements at 532 nm use new highly sensitive photon counting detectors, and measure the height distributions of very thin clouds and aerosol layers. With averaging these can be used to determine the height of the planetary boundary layer. The instrument design and expected performance will be discussed.

  13. Geoid modeling in Mexico and the collaboration with Central America and the Caribbean.

    NASA Astrophysics Data System (ADS)

    Avalos, D.; Gomez, R.

    2012-12-01

    The model of geoidal heights for Mexico, named GGM10, is presented as a geodetic tool to support vertical positioning in the context of regional height system unification. It is a purely gravimetric solution computed by the Stokes-Helmert technique in resolution of 2.5 arc minutes. This product from the Instituto Nacional de Estadistica y Geografia (INEGI) is released together with a series of 10 gravimetric models which add to the improvements in description of the gravity field. In the recent years, the INEGI joined the initiative of the U.S. National Geodetic Survey and the Canada's Geodetic Survey Division to promote the regional height system unification. In an effort to further improve the compatibility among national geoid models in the region, the INEGI has begun to champion a network of specialists that includes national representatives from Central America and the Caribbean. Through the opening of opportunities for training and more direct access to international agreements and discussions, the tropical region is gaining participation. Now a significantly increased number of countries is pushing for a future North and Central American geoid-based vertical datum as support of height system unification.eoidal height in Mexico, mapped from the model GGM10.

  14. Marked increase of final height by long-term aromatase inhibition in a boy with idiopathic short stature.

    PubMed

    Krebs, Andreas; Moske-Eick, Olaf; Doerfer, Jürgen; Roemer-Pergher, Cordula; van der Werf-Grohmann, Natascha; Schwab, Karl Otfried

    2012-01-01

    Growth hormone (GH) is the most frequently used treatment in children with idiopathic short stature (ISS). Aromatase inhibitor (AI) therapy is still in an experimental state, and both final height (FH) and long-term efficacy data in ISS have not been published. We present a 14.5-year-old boy with ISS and a height of 142.7 cm [standard deviation score (SDS) -2.79]. Based on the baseline bone age (BA) of 13.5-14 years, his predicted adult height (PAH) by Bayley/Pinneau was 154 cm (SDS -3.77)-158.2 (SDS -3.15). After a 5-year letrozole monotherapy, FH was 169 cm (SDS -1.57) showing a height difference between PAH and FH from 10.8 to 15 cm. No permanent side effects of the medication have been observed. Both a transient occurrence and a spontaneous recovery of decreased bone mineral apparent density were seen, verified by dual-energy X-ray absorptiometry. Spinal magnetic resonance imaging revealed no vertebral abnormalities. All therapy might be an effective and low-cost alternative to the use of GH. Further controlled trials should prove efficacy and safety of long-term AI therapy in boys with ISS.

  15. On vertical profile of ozone at Syowa

    NASA Technical Reports Server (NTRS)

    Chubachi, Shigeru

    1994-01-01

    The difference in the vertical ozone profile at Syowa between 1966-1981 and 1982-1988 is shown. The month-height cross section of the slope of the linear regressions between ozone partial pressure and 100-mb temperature is also shown. The vertically integrated values of the slopes are in close agreement with the slopes calculated by linear regression of Dobson total ozone on 100-mb temperature in the period of 1982-1988.

  16. Characterization of vertical mixing in oscillatory vegetated flows

    NASA Astrophysics Data System (ADS)

    Abdolahpour, M.; Ghisalberti, M.; Lavery, P.; McMahon, K.

    2016-02-01

    Seagrass meadows are primary producers that provide important ecosystem services, such as improved water quality, sediment stabilisation and trapping and recycling of nutrients. Most of these ecological services are strongly influenced by the vertical exchange of water across the canopy-water interface. That is, vertical mixing is the main hydrodynamic process governing the large-scale ecological and environmental impact of seagrass meadows. The majority of studies into mixing in vegetated flows have focused on steady flow environments whereas many coastal canopies are subjected to oscillatory flows driven by surface waves. It is known that the rate of mass transfer will vary greatly between unidirectional and oscillatory flows, necessitating a specific investigation of mixing in oscillatory canopy flows. In this study, we conducted an extensive laboratory investigation to characterise the rate of vertical mixing through a vertical turbulent diffusivity (Dt,z). This has been done through gauging the evolution of vertical profiles of concentration (C) of a dye sheet injected into a wave-canopy flow. Instantaneous measurement of the variance of the vertical concentration distribution ( allowed the estimation of a vertical turbulent diffusivity (). Two types of model canopies, rigid and flexible, with identical heights and frontal areas, were subjected to a wide and realistic range of wave height and period. The results showed two important mechanisms that dominate vertical mixing under different conditions: a shear layer that forms at the top of the canopy and wake turbulence generated by the stems. By allowing a coupled contribution of wake and shear layer mixing, we present a relationship that can be used to predict the rate of vertical mixing in coastal canopies. The results further showed that the rate of vertical mixing within flexible vegetation was always lower than the corresponding rigid canopy, confirming the impact of plant flexibility on canopy-flow interactions.

  17. Effects of lead and cadmium exposure from electronic waste on child physical growth.

    PubMed

    Yang, Hui; Huo, Xia; Yekeen, Taofeek Akangbe; Zheng, Qiujian; Zheng, Minghao; Xu, Xijin

    2013-07-01

    Many studies indicate that lead (Pb) and cadmium (Cd) exposure may alter bone development through both direct and indirect mechanisms, increasing the risk of osteoporosis later in life. The aim of this study was to investigate the association between Pb and Cd exposure, physical growth, and bone and calcium metabolism in children of an electronic waste (e-waste) processing area. We recruited 246 children (3-8 years) in a kindergarten located in Guiyu, China. Blood lead levels (BLLs) and blood cadmium levels (BCLs) of recruited children were measured as biomarkers for exposure. Serum calcium, osteocalcin, bone alkaline phosphatase, and urinary deoxypyridinoline were used as biomarkers for bone and calcium metabolism. Physical indexes such as height, weight, and head and chest circumference were also measured. The mean values of BLLs and BCLs obtained were 7.30 μg/dL and 0.69 μg/L, respectively. The average of BCLs increased with age. In multiple linear regression analysis, BLLs were negatively correlated with both height and weight, and positively correlated with bone resorption biomarkers. Neither bone nor calcium metabolic biomarkers showed significant correlation with cadmium. Childhood lead exposure affected both physical development and increased bone resorption of children in Guiyu. Primitive e-waste recycling may threaten the health of children with elevated BLL which may eventually cause adult osteoporosis.

  18. Long-term follow-up on soft and hard tissue levels following guided bone regeneration treatment in combination with a xenogeneic filling material: a 5-year prospective clinical study.

    PubMed

    Dahlin, C; Simion, M; Hatano, N

    2010-12-01

    In the present prospective study, bone augmentation by guided bone regeneration (GBR) in combination with bovine hydroxyapatite (BHA) as filling material was evaluated with regard to soft and hard tissue stability over time. Implant survival, radiologic bone level (marginal bone level [MBL]), and clinical soft tissue parameters (marginal soft tissue level [MSTL]) were observed. Twenty patients received a total of 41 implants (Brånemark System, Nobel Biocare, Göteborg, Sweden) in conjunction with GBR treatment. The end point of the study was after 5 years following implant placement. The cumulative implant survival rate was 97.5% corresponding to one implant failure. The radiologic evaluation of the MBL demonstrated a crestal bone height above the level of the fixture head. The bone height decreased from -3.51 to -2.38 mm (p < .001). The MSTL was -1.52 mm at baseline and -1.15 mm at the 5-year follow-up (p < .04) demonstrating a stable submucosal crown margin throughout the study period. GBR treatment in combination with a xenogeneic filling material (BHA) is a viable treatment option in order to maintain stable hard and soft tissue levels in conjunction with augmentative procedure related to oral implant treatment. © 2009, Copyright the Authors. Journal Compilation © 2010, Wiley Periodicals, Inc.

  19. Trauma of facial skeleton in children: An indian perspective.

    PubMed

    Karim, Tanweer; Khan, Arshad Hafeez; Ahmed, Syed Saeed

    2010-06-01

    Both children and adults are subject to similar types of injuries but fractures of facial bones in children are relatively uncommon. The aim of this study was to evaluate the epidemiology of facial bone fractures among children of <12 years, their management and outcome in an Indian city. This retrospective study included children of <12 years of age with facial bone fractures admitted over a span of 3 years. In order to compare our results we reviewed the existing literature related to pediatric facial bone fractures. A total of 45 children were admitted for facial bone fractures. Forty (89%) of them were above 5 years of age and male to female ratio was 2:1. About 53.33% of these injuries were because of fall from height. Mandible fracture was the most common facial bone fracture among admitted patients. Symphysis and para-symphysis was the commonest site of mandibular fractures, seen in 49% cases. Majority of these fractures were managed by Inter-maxillary fixation and inter-osseous wiring. Mini-plates were used for widely displaced compound fractures. For un-displaced fractures observation alone was sufficient. Mandible is the commonest facial bone fracture in children, more often caused by accidental fall from height. The high osteogenic potential of pediatric mandible allows non-surgical management to be successful in an increased proportion of younger patients.

  20. Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element analysis.

    PubMed

    Bacchi, Ataís; Consani, Rafael L X; Mesquita, Marcelo F; dos Santos, Mateus B F

    2013-09-01

    The purpose of this study was to evaluate the influence of superstructure material and vertical misfits on the stresses created in an implant-supported partial prosthesis. A three-dimensional (3-D) finite element model was prepared based on common clinical data. The posterior part of a severely resorbed jaw with two osseointegrated implants at the second premolar and second molar regions was modeled using specific modeling software (SolidWorks 2010). Finite element models were created by importing the solid model into mechanical simulation software (ANSYS Workbench 11). The models were divided into groups according to the prosthesis framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy, or zirconia) and vertical misfit level (10 µm, 50 µm, and 100 µm) created at one implant-prosthesis interface. The gap of the vertical misfit was set to be closed and the stress values were measured in the framework, porcelain veneer, retention screw, and bone tissue. Stiffer materials led to higher stress concentration in the framework and increased stress values in the retention screw, while in the same circumstances, the porcelain veneer showed lower stress values, and there was no significant difference in stress in the peri-implant bone tissue. A considerable increase in stress concentration was observed in all the structures evaluated within the misfit amplification. The framework material influenced the stress concentration in the prosthetic structures and retention screw, but not that in bone tissue. All the structures were significantly influenced by the increase in the misfit levels.

Top