Sample records for vessel system final

  1. 75 FR 18110 - Antarctic Marine Living Resources; Use of Centralized-Vessel Monitoring System and Importation of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-09

    .... 0907141130-0112-02] RIN 0648-AX80 Antarctic Marine Living Resources; Use of Centralized-Vessel Monitoring... documentation that the harvesting vessel participated in the Centralized-Vessel Monitoring System (C-VMS... Centralized-Vessel Monitoring System (C-VMS) regardless of where the fish was harvested. This final rule also...

  2. 77 FR 38729 - Alternate Tonnage Threshold for Oil Spill Response Vessels

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-29

    ...The Coast Guard is establishing an alternate size threshold based on the measurement system established under the International Convention on Tonnage Measurement of Ships, 1969, for oil spill response vessels, which are properly certificated under 46 CFR chapter I, subchapter L. The present size threshold of 500 gross register tons is based on the U.S. regulatory measurement system. This final rule provides an alternative for owners and operators of offshore supply vessels that may result in an increase in oil spill response capacity and capability. This final rule adopts, without change, the interim rule amending 46 CFR part 126 published in the Federal Register on Monday, December 12, 2011.

  3. FINAL DESIGN REVIEW REPORT Subcritical Experiments Gen 2, 3-ft Confinement Vessel Weldment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romero, Christopher

    A Final Design Review (FDR) of the Subcritical Experiments (SCE) Gen 2, 3-ft. Confinement Vessel Weldment was held at Los Alamos National Laboratory (LANL) on September 14, 2017. The review was a focused review on changes only to the confinement vessel weldment (versus a system design review). The changes resulted from lessons-learned in fabricating and inspecting the current set of confinement vessels used for the SCE Program. The baseline 3-ft. confinement vessel weldment design has successfully been used (to date) for three (3) high explosive (HE) over-tests, two (2) fragment tests, and five (5) integral HE experiments. The design teammore » applied lessons learned from fabrication and inspection of these vessel weldments to enhance fit-up, weldability, inspection, and fitness for service evaluations. The review team consisted of five (5) independent subject matter experts with engineering design, analysis, testing, fabrication, and inspection experience. The« less

  4. Vessel extraction in retinal images using automatic thresholding and Gabor Wavelet.

    PubMed

    Ali, Aziah; Hussain, Aini; Wan Zaki, Wan Mimi Diyana

    2017-07-01

    Retinal image analysis has been widely used for early detection and diagnosis of multiple systemic diseases. Accurate vessel extraction in retinal image is a crucial step towards a fully automated diagnosis system. This work affords an efficient unsupervised method for extracting blood vessels from retinal images by combining existing Gabor Wavelet (GW) method with automatic thresholding. Green channel image is extracted from color retinal image and used to produce Gabor feature image using GW. Both green channel image and Gabor feature image undergo vessel-enhancement step in order to highlight blood vessels. Next, the two vessel-enhanced images are transformed to binary images using automatic thresholding before combined to produce the final vessel output. Combining the images results in significant improvement of blood vessel extraction performance compared to using individual image. Effectiveness of the proposed method was proven via comparative analysis with existing methods validated using publicly available database, DRIVE.

  5. New baking system for the RFX vacuum vessel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collarin, P.; Luchetta, A.; Sonato, P.

    A heating system based on eddy currents has been developed for the vacuum vessel of the RFX Reversed Field Pinch device. After a testing phase, carried out at low power, the final power supply system has been designed and installed. It has been used during last year to bake out the vessel and the graphite first wall up to 320{degree}C. Recently the heating system has been completed with a control system that allows for baking sessions with an automatic control of the vacuum vessel temperature and for pulse sessions with a heated first wall. After the description of the preliminarymore » analyses and tests, and of the main characteristics of the power supply and control systems, the experimental results of the baking sessions performed during last year are presented. 6 refs., 7 figs.« less

  6. 78 FR 21938 - Final National Pollutant Discharge Elimination System (NPDES) General Permit for Discharges...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-12

    ... shore and then enters the Great Lakes, and (2) the vessel has taken on ballast water that has a salinity... a vessel meeting the description in (1) has not taken on ballast water with a salinity of less than...

  7. Dynamics of an Overdriven Nitromethane Initiation System

    NASA Astrophysics Data System (ADS)

    Hároz, E. H.; Rae, P. J.; Armstrong, C. L.; Baca, E. V.; Campbell, C.; Gunderson, J. A.; Holmes, M.; Lopez-Pulliam, I.; Vaughan, L. D.; Dickson, P. M.

    2017-06-01

    For upcoming large-scale HE experiments, an initiation system is needed to ensure uniform and simultaneous burn. To that end, we developed an initiation system based on nitromethane. Initial, small-scale tests characterized the response of the nitromethane in the proposed cylindrical initiator geometry, indicating robust detonation under a variety of conditions such as a plane wave lenses & cylinders of PBX 9501 into a flyer plate or direct-drive. Detonation velocity, as measured by piezoelectric pin time-of-arrival measurements along the length and at bottom of vessel, shows an overdriven response. All cases show a detonation velocity faster than the literature value of 7.3 km s-1 for nitromethane, with the fastest velocity occurring for the 8-detonator, 8'' cylinder case with a velocity = 7.7 km s-1. Streak camera imaging characterized the curvature of the shock front as it arrived at the bottom of the vessel via spark gap. A final test of the initiator system looked at the expansion of the initiator vessel walls via PDV, showing velocities up to 3.5 km s-1. Finally, our initiator was placed inside a secondary vessel containing 1000 lbs of nitromethane. High-speed photography & pin data indicate complete symmetrical burn of the secondary nitromethane.

  8. Maintenance method and its critical issues for a fast-ignition laser fusion reactor based on a dry wall chamber

    NASA Astrophysics Data System (ADS)

    Someya, Y.; Matsumoto, T.; Okano, K.; Asaoka, Y.; Hiwatari, R.; Goto, T.; Ogawa, Y.

    2008-05-01

    The neutronics analysis has been carried out for feasibility study of the FALCON-D concept by Monte Carlo N-paticle transport code (MCNP), in order to inspect the cooling performance of in-vessel and ex-vessel components, and a connection pipe between Vacuum Vessel and reactor room. The nuclear heating rate in the Vacuum Vessel was at the same level as that of NBI duct of the ITER. The temperature of the connection pipe was found to be 345·, ·which was smaller than the melting point of structure materials (F82H). Moreover, the radiation damage of the final optics was also investigated. We propose a sliding changer concept for replacement. This method could be adapted for the replacement of one FPY cycle in the final optics system.

  9. Development of Remote-Type Haptic Catheter Sensor System using Piezoelectric Transducer

    NASA Astrophysics Data System (ADS)

    Haruta, Mineyuki; Murayama, Yoshinobu; Omata, Sadao

    This study describes the development of Remote-Type Haptic Catheter Sensor System which enables the mechanical property evaluation of a blood vessel. This system consists of a feedback circuit and a piezoelectric ultrasound transducer, and is operated based on a phase shift method so that the entire system oscillates at its inherent resonance frequency. Ultrasound reflected by the blood vessel makes a phase shift of the resonance system depending on the acoustic impedance of the reflector. The phase shift is then measured as a change in resonance frequency of the system; therefore, the detection resolution is highly improved. The correlation between the acoustic impedance and the resonance frequency change of the sensor system was demonstrated using silicone rubbers, metals and actual blood vessels from a pig. The performance of the sensor was also examined using vessel shaped phantom model. Finally, the discussion surveys a possibility of the novel sensor system in an application for intra vascular diagnosis.

  10. Segmentation of Retinal Blood Vessels Based on Cake Filter

    PubMed Central

    Bao, Xi-Rong; Ge, Xin; She, Li-Huang; Zhang, Shi

    2015-01-01

    Segmentation of retinal blood vessels is significant to diagnosis and evaluation of ocular diseases like glaucoma and systemic diseases such as diabetes and hypertension. The retinal blood vessel segmentation for small and low contrast vessels is still a challenging problem. To solve this problem, a new method based on cake filter is proposed. Firstly, a quadrature filter band called cake filter band is made up in Fourier field. Then the real component fusion is used to separate the blood vessel from the background. Finally, the blood vessel network is got by a self-adaption threshold. The experiments implemented on the STARE database indicate that the new method has a better performance than the traditional ones on the small vessels extraction, average accuracy rate, and true and false positive rate. PMID:26636095

  11. Black blood MRI in suspected large artery primary angiitis of the central nervous system.

    PubMed

    Pfefferkorn, Thomas; Linn, Jennifer; Habs, Maximilian; Opherk, Christina; Cyran, Clemens; Ottomeyer, Caroline; Straube, Andreas; Dichgans, Martin; Nikolaou, Konstantin; Saam, Tobias

    2013-07-01

    Single case reports suggest that black blood MRI (T1-weighted fat and blood suppressed sequences with and without contrast injection; BB-MRI) may visualize intracranial vessel wall contrast enhancement (CE) in primary angiitis of the central nervous system (PACNS). In this single-center observational pilot study we prospectively investigated the value of BB-MRI in the diagnosis of large artery PACNS. Patients with suspected large artery PACNS received a standardized diagnostic program including BB-MRI. Vessel wall CE was graded (grade 0-2) by two experienced readers blinded to clinical data and correlated to the final diagnosis. Four of 12 included patients received a final diagnosis of PACNS. All of them showed moderate (grade 1) to strong (grade 2) vessel wall CE at the sites of stenosis. A moderate (grade 1) vessel wall CE grade was also observed in 6 of the remaining 8 patients in whom alternative diagnoses were made: arteriosclerotic disease (n = 4), intracranial dissection (n = 1), and Moyamoya disease (n = 1). Our pilot study demonstrates that vessel wall CE is a frequent finding in PACNS and its mimics. Larger trials will be necessary to evaluate the utility of BB-MRI in the diagnostic workup of PACNS. Copyright © 2012 by the American Society of Neuroimaging.

  12. Automatic detection of lung vessel bifurcation in thoracic CT images

    NASA Astrophysics Data System (ADS)

    Maduskar, Pragnya; Vikal, Siddharth; Devarakota, Pandu

    2011-03-01

    Computer-aided diagnosis (CAD) systems for detection of lung nodules have been an active topic of research for last few years. It is desirable that a CAD system should generate very low false positives (FPs) while maintaining high sensitivity. This work aims to reduce the number of false positives occurring at vessel bifurcation point. FPs occur quite frequently on vessel branching point due to its shape which can appear locally spherical due to the intrinsic geometry of intersecting tubular vessel structures combined with partial volume effects and soft tissue attenuation appearance surrounded by parenchyma. We propose a model-based technique for detection of vessel branching points using skeletonization, followed by branch-point analysis. First we perform vessel structure enhancement using a multi-scale Hessian filter to accurately segment tubular structures of various sizes followed by thresholding to get binary vessel structure segmentation [6]. A modified Reebgraph [7] is applied next to extract the critical points of structure and these are joined by a nearest neighbor criterion to obtain complete skeletal model of vessel structure. Finally, the skeletal model is traversed to identify branch points, and extract metrics including individual branch length, number of branches and angle between various branches. Results on 80 sub-volumes consisting of 60 actual vessel-branching and 20 solitary solid nodules show that the algorithm identified correctly vessel branching points for 57 sub-volumes (95% sensitivity) and misclassified 2 nodules as vessel branch. Thus, this technique has potential in explicit identification of vessel branching points for general vessel analysis, and could be useful in false positive reduction in a lung CAD system.

  13. 46 CFR Appendix II to Part 390 - Sample Capital Construction Fund Agreement

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) In the case of a vessel constructed or acquired within one year of final delivery from the shipyard... date of such vessel's final delivery; (2) In the case of a vessel reconstructed or acquired more than one year after final delivery from the shipyard after construction with the aid of qualified...

  14. 46 CFR Appendix II to Part 390 - Sample Capital Construction Fund Agreement

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) In the case of a vessel constructed or acquired within one year of final delivery from the shipyard... date of such vessel's final delivery; (2) In the case of a vessel reconstructed or acquired more than one year after final delivery from the shipyard after construction with the aid of qualified...

  15. SNS Central Helium Liquefier spare Carbon Bed installation and commissioning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Degraff, Brian D.; Howell, Matthew P.; Kim, Sang-Ho

    The Spallation Neutron Source (SNS) Central Helium Liquefier (CHL) at Oak Ridge National Laboratory (ORNL) has been without major operations downtime since operations were started back in 2006. This system utilizes a vessel filled with activated carbon as the final major component to remove oil vapor from the compressed helium circuit prior to insertion into the system's cryogenic cold box. The need for a spare carbon bed at SNS due to the variability of carbon media lifetime calculation to adsorption efficiency will be discussed. The fabrication, installation and commissioning of this spare carbon vessel will be presented. The novel planmore » for connecting the spare carbon vessel piping to the existing infrastructure will be presented.« less

  16. Development of an oxygen saturation measuring system by using near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Kono, K.; Nakamachi, E.; Morita, Y.

    2017-08-01

    Recently, the hypoxia imaging has been recognized as the advanced technique to detect cancers because of a strong relationship with the biological characterization of cancer. In previous studies, hypoxia imaging systems for endoscopic diagnosis have been developed. However, these imaging technologies using the visible light can observe only blood vessels in gastric mucous membrane. Therefore, they could not detect scirrhous gastric cancer which accounts for 10% of all gastric cancers and spreads rapidly into submucous membrane. To overcome this problem, we developed a measuring system of blood oxygen saturation in submucous membrane by using near-infrared (NIR) spectroscopy. NIR, which has high permeability for bio-tissues and high absorbency for hemoglobin, can image and observe blood vessels in submucous membrane. NIR system with LED lights and a CCD camera module was developed to image blood vessels. We measured blood oxygen saturation using the optical density ratio (ODR) of two wavelengths, based on Lambert-Beer law. To image blood vessel clearly and measure blood oxygen saturation accurately, we searched two optimum wavelengths by using a multilayer human gastric-like phantom which has same optical properties as human gastric one. By using Monte Carlo simulation of light propagation, we derived the relationship between the ODR and blood oxygen saturation and elucidated the influence of blood vessel depth on measuring blood oxygen saturation. The oxygen saturation measuring methodology was validated with experiments using our NIR system. Finally, it was confirmed that our system can detect oxygen saturation in various depth blood vessels accurately.

  17. Major hepatectomy using the glissonean approach in cases of right umbilical portion

    PubMed Central

    Ome, Yusuke; Kawamoto, Kazuyuki; Park, Tae Bum; Ito, Tadashi

    2016-01-01

    Right umbilical portion (RUP) is a rare congenital anomaly associated with anomalous ramifications of the hepatic vessels and biliary system. As such, major hepatectomy requires a careful approach. We describe the usefulness of the Glissonean approach in two patients with vessel anomalies, such as RUP. The first patient underwent a right anterior sectionectomy for intrahepatic cholangiocarcinoma. We encircled several Glissonean pedicles that entered the right anterior section along the right side of the RUP. We temporarily clamped each pedicle, confirmed the demarcation area, and finally cut them. The operation was performed safely and was successful. The second patient underwent a left trisectionectomy for perihilar cholangiocarcinoma. We secured the right posterior Glissonean pedicle. The vessels in the pedicle were preserved, and the other vessels and contents were resected. Identifying the vessels for preservation facilitated the safe lymphadenectomy and dissection of the vessels to be resected. We successfully performed the operation. PMID:28008345

  18. 46 CFR 112.15-5 - Final emergency loads.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... or gas turbines that drive emergency generators; and (3) General alarm batteries. (d) One of the... of the subchapter under which the vessel is certificated. (f) Each sprinkler system, water spray extinguishing system, or foam system pump. (g) If necessary, the lube oil pump for each propulsion turbine and...

  19. 46 CFR 112.15-5 - Final emergency loads.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... or gas turbines that drive emergency generators; and (3) General alarm batteries. (d) One of the... of the subchapter under which the vessel is certificated. (f) Each sprinkler system, water spray extinguishing system, or foam system pump. (g) If necessary, the lube oil pump for each propulsion turbine and...

  20. 46 CFR 112.15-5 - Final emergency loads.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... or gas turbines that drive emergency generators; and (3) General alarm batteries. (d) One of the... of the subchapter under which the vessel is certificated. (f) Each sprinkler system, water spray extinguishing system, or foam system pump. (g) If necessary, the lube oil pump for each propulsion turbine and...

  1. Study on the quality of FRP fishing vessel based on improved Fishbone Chart

    NASA Astrophysics Data System (ADS)

    Sui, J. H.; Yu, Y. F.; Du, Q. F.; Jiang, D. W.

    2018-01-01

    The construction quality of FRP fishing vessels influences their production, use and industry development. In order to explore the factors that affect the construction quality of FRP fishing vessels, key factors affecting the construction quality of FRP fishing vessels are determined based on the quality problems of FRP fishing vessels constructed. The improved Fishbone Chart is used to analyze the eight factors of “human, machine, material, process, environment, inspection, design and information”. Taking the factors that affect the construction quality of FRP fishing vessels as the central target, the eight influencing factors were condensed into five aspects and a composite Fishbone Chart is drawn. The Fishbone Chart is used as the basic model, the influencing factors are sorted, screened and discriminated, and the system model convenient for construction site management and control is established. Finally, the causes of poor construction of FRP fishing vessels are analyzed and discussed, and relevant suggestions are put forward.

  2. Insulation Progress since the Mid-1950s

    NASA Astrophysics Data System (ADS)

    Timmerhaus, K. D.

    Storage vessel and cryostat design for modern cryogenic systems has become rather routine as the result of the wide use of and application of cryogenic fluids. Such vessels for these fluids range in size from 1 L flasks used in the laboratory for liquid nitrogen to the more than 200,000 m3 double-walled tanks used for temporary storage of liquefied natural gas before being transported overseas to their final destination. These storage vessels for cryogenic fluids range in type from low-performance containers insulated with rigid foam or fibrous insulation to high-performance containers insulated with evacuated multilayer insulations. The overriding factors in the type of container selected normally are of economics and safety. This paper will consider various insulation concepts used in such cryogenic storage systems and will review the progress that has been made over the past 50 years in these insulation systems.

  3. Automated tracking and quantification of angiogenic vessel formation in 3D microfluidic devices.

    PubMed

    Wang, Mengmeng; Ong, Lee-Ling Sharon; Dauwels, Justin; Asada, H Harry

    2017-01-01

    Angiogenesis, the growth of new blood vessels from pre-existing vessels, is a critical step in cancer invasion. Better understanding of the angiogenic mechanisms is required to develop effective antiangiogenic therapies for cancer treatment. We culture angiogenic vessels in 3D microfluidic devices under different Sphingosin-1-phosphate (S1P) conditions and develop an automated vessel formation tracking system (AVFTS) to track the angiogenic vessel formation and extract quantitative vessel information from the experimental time-lapse phase contrast images. The proposed AVFTS first preprocesses the experimental images, then applies a distance transform and an augmented fast marching method in skeletonization, and finally implements the Hungarian method in branch tracking. When applying the AVFTS to our experimental data, we achieve 97.3% precision and 93.9% recall by comparing with the ground truth obtained from manual tracking by visual inspection. This system enables biologists to quantitatively compare the influence of different growth factors. Specifically, we conclude that the positive S1P gradient increases cell migration and vessel elongation, leading to a higher probability for branching to occur. The AVFTS is also applicable to distinguish tip and stalk cells by considering the relative cell locations in a branch. Moreover, we generate a novel type of cell lineage plot, which not only provides cell migration and proliferation histories but also demonstrates cell phenotypic changes and branch information.

  4. Automatic multiscale enhancement and segmentation of pulmonary vessels in CT pulmonary angiography images for CAD applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou Chuan; Chan, H.-P.; Sahiner, Berkman

    2007-12-15

    The authors are developing a computerized pulmonary vessel segmentation method for a computer-aided pulmonary embolism (PE) detection system on computed tomographic pulmonary angiography (CTPA) images. Because PE only occurs inside pulmonary arteries, an automatic and accurate segmentation of the pulmonary vessels in 3D CTPA images is an essential step for the PE CAD system. To segment the pulmonary vessels within the lung, the lung regions are first extracted using expectation-maximization (EM) analysis and morphological operations. The authors developed a 3D multiscale filtering technique to enhance the pulmonary vascular structures based on the analysis of eigenvalues of the Hessian matrix atmore » multiple scales. A new response function of the filter was designed to enhance all vascular structures including the vessel bifurcations and suppress nonvessel structures such as the lymphoid tissues surrounding the vessels. An EM estimation is then used to segment the vascular structures by extracting the high response voxels at each scale. The vessel tree is finally reconstructed by integrating the segmented vessels at all scales based on a 'connected component' analysis. Two CTPA cases containing PEs were used to evaluate the performance of the system. One of these two cases also contained pleural effusion disease. Two experienced thoracic radiologists provided the gold standard of pulmonary vessels including both arteries and veins by manually tracking the arterial tree and marking the center of the vessels using a computer graphical user interface. The accuracy of vessel tree segmentation was evaluated by the percentage of the 'gold standard' vessel center points overlapping with the segmented vessels. The results show that 96.2% (2398/2494) and 96.3% (1910/1984) of the manually marked center points in the arteries overlapped with segmented vessels for the case without and with other lung diseases. For the manually marked center points in all vessels including arteries and veins, the segmentation accuracy are 97.0% (4546/4689) and 93.8% (4439/4732) for the cases without and with other lung diseases, respectively. Because of the lack of ground truth for the vessels, in addition to quantitative evaluation of the vessel segmentation performance, visual inspection was conducted to evaluate the segmentation. The results demonstrate that vessel segmentation using our method can extract the pulmonary vessels accurately and is not degraded by PE occlusion to the vessels in these test cases.« less

  5. Automatic Tortuosity-Based Retinopathy of Prematurity Screening System

    NASA Astrophysics Data System (ADS)

    Sukkaew, Lassada; Uyyanonvara, Bunyarit; Makhanov, Stanislav S.; Barman, Sarah; Pangputhipong, Pannet

    Retinopathy of Prematurity (ROP) is an infant disease characterized by increased dilation and tortuosity of the retinal blood vessels. Automatic tortuosity evaluation from retinal digital images is very useful to facilitate an ophthalmologist in the ROP screening and to prevent childhood blindness. This paper proposes a method to automatically classify the image into tortuous and non-tortuous. The process imitates expert ophthalmologists' screening by searching for clearly tortuous vessel segments. First, a skeleton of the retinal blood vessels is extracted from the original infant retinal image using a series of morphological operators. Next, we propose to partition the blood vessels recursively using an adaptive linear interpolation scheme. Finally, the tortuosity is calculated based on the curvature of the resulting vessel segments. The retinal images are then classified into two classes using segments characterized by the highest tortuosity. For an optimal set of training parameters the prediction is as high as 100%.

  6. Intelligent Gateway design and development : final report

    DOT National Transportation Integrated Search

    1996-10-01

    The U.S. Coast Guard (USCG) had communications requirements uncommon to other services. Currently, there were no Defense Message System (DMS) products that could be used to send messages to underway vessels with multiple modes of communications. The ...

  7. Unmanned surface vessel (USV) systems for bridge inspection : final report.

    DOT National Transportation Integrated Search

    2016-08-01

    The use of unmanned surface vehicles (USVs) for bridge inspection has been explored. The following issues were considered: (1) the requirements of and : current techniques utilized in on-water bridge inspection; (2) USV design and configuration consi...

  8. Retina vascular network recognition

    NASA Astrophysics Data System (ADS)

    Tascini, Guido; Passerini, Giorgio; Puliti, Paolo; Zingaretti, Primo

    1993-09-01

    The analysis of morphological and structural modifications of the retina vascular network is an interesting investigation method in the study of diabetes and hypertension. Normally this analysis is carried out by qualitative evaluations, according to standardized criteria, though medical research attaches great importance to quantitative analysis of vessel color, shape and dimensions. The paper describes a system which automatically segments and recognizes the ocular fundus circulation and micro circulation network, and extracts a set of features related to morphometric aspects of vessels. For this class of images the classical segmentation methods seem weak. We propose a computer vision system in which segmentation and recognition phases are strictly connected. The system is hierarchically organized in four modules. Firstly the Image Enhancement Module (IEM) operates a set of custom image enhancements to remove blur and to prepare data for subsequent segmentation and recognition processes. Secondly the Papilla Border Analysis Module (PBAM) automatically recognizes number, position and local diameter of blood vessels departing from optical papilla. Then the Vessel Tracking Module (VTM) analyses vessels comparing the results of body and edge tracking and detects branches and crossings. Finally the Feature Extraction Module evaluates PBAM and VTM output data and extracts some numerical indexes. Used algorithms appear to be robust and have been successfully tested on various ocular fundus images.

  9. Computer analysis of arteriograms

    NASA Technical Reports Server (NTRS)

    Selzer, R. H.; Armstrong, J. H.; Beckenbach, E. B.; Blankenhorn, D. H.; Crawford, D. W.; Brooks, S. H.; Sanmarco, M. E.

    1977-01-01

    A computer system has been developed to quantify the degree of atherosclerosis in the human femoral artery. The analysis involves first scanning and digitizing angiographic film, then tracking the outline of the arterial image and finally computing the relative amount of roughness or irregularity in the vessel wall. The image processing system and method are described.

  10. SNS Central Helium Liquefier spare Carbon Bed installation and commissioning

    NASA Astrophysics Data System (ADS)

    DeGraff, B.; Howell, M.; Kim, S.; Neustadt, T.

    2017-12-01

    The Spallation Neutron Source (SNS) Central Helium Liquefier (CHL) at Oak Ridge National Laboratory (ORNL) has been without major operations downtime since operations were started back in 2006. This system utilizes a vessel filled with activated carbon as the final major component to remove oil vapor from the compressed helium circuit prior to insertion into the system’s cryogenic cold box. The need for a spare carbon bed at SNS due to the variability of carbon media lifetime calculation to adsorption efficiency will be discussed. The fabrication, installation and commissioning of this spare carbon vessel will be presented. The novel plan for connecting the spare carbon vessel piping to the existing infrastructure will be presented.

  11. 75 FR 55973 - Salvage and Marine Firefighting Requirements; Vessel Response Plans for Oil

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-15

    ... and Marine Firefighting Requirements; Vessel Response Plans for Oil AGENCY: Coast Guard, DHS. ACTION... the vessel response plan salvage and marine firefighting requirements for tank vessels carrying oil... Marine Firefighting Requirements; Vessel Response Plans for Oil'' (73 FR 80618). The final rule amended...

  12. Investigation of the design of a metal-lined fully wrapped composite vessel under high internal pressure

    NASA Astrophysics Data System (ADS)

    Kalaycıoğlu, Barış; Husnu Dirikolu, M.

    2010-09-01

    In this study, a Type III composite pressure vessel (ISO 11439:2000) loaded with high internal pressure is investigated in terms of the effect of the orientation of the element coordinate system while simulating the continuous variation of the fibre angle, the effect of symmetric and non-symmetric composite wall stacking sequences, and lastly, a stacking sequence evaluation for reducing the cylindrical section-end cap transition region stress concentration. The research was performed using an Ansys® model with 2.9 l volume, 6061 T6 aluminium liner/Kevlar® 49-Epoxy vessel material, and a service internal pressure loading of 22 MPa. The results show that symmetric stacking sequences give higher burst pressures by up to 15%. Stacking sequence evaluations provided a further 7% pressure-carrying capacity as well as reduced stress concentration in the transition region. Finally, the Type III vessel under consideration provides a 45% lighter construction as compared with an all metal (Type I) vessel.

  13. Seasonal characterisation of maritime traffic and the relationship with cetacean presence in the Western Mediterranean Sea.

    PubMed

    Campana, I; Angeletti, D; Crosti, R; Luperini, C; Ruvolo, A; Alessandrini, A; Arcangeli, A

    2017-02-15

    Seasonal maritime traffic was investigated in relation to cetaceans, through direct observations (July 2013-June 2015) along three fixed transects in Western Mediterranean. Visually obtained vessel abundance was compared with Automatic Identification System data to explore if the two methods provided different results. Traffic intensity and composition were characterised by seasons and vessel categories. Finally, cetacean presence was investigated in relation to traffic by measuring the difference of vessel abundance in the presence and absence of animal sightings. Results showed that visual sampling was consistent with AIS data, providing more information on small-medium vessels. Traffic was more intense and diverse in Spring/Summer, and the highest vessel abundance and seasonal variations in composition emerged for inshore subareas. The difference of traffic in the presence and absence of cetaceans was higher in most offshore subareas in Spring/Summer, verified for B. physalus and S. coeruleoalba; in inshore waters, mostly occupied by T. truncatus, no significant differences emerged. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Retinal blood vessel segmentation using fully convolutional network with transfer learning.

    PubMed

    Jiang, Zhexin; Zhang, Hao; Wang, Yi; Ko, Seok-Bum

    2018-04-26

    Since the retinal blood vessel has been acknowledged as an indispensable element in both ophthalmological and cardiovascular disease diagnosis, the accurate segmentation of the retinal vessel tree has become the prerequisite step for automated or computer-aided diagnosis systems. In this paper, a supervised method is presented based on a pre-trained fully convolutional network through transfer learning. This proposed method has simplified the typical retinal vessel segmentation problem from full-size image segmentation to regional vessel element recognition and result merging. Meanwhile, additional unsupervised image post-processing techniques are applied to this proposed method so as to refine the final result. Extensive experiments have been conducted on DRIVE, STARE, CHASE_DB1 and HRF databases, and the accuracy of the cross-database test on these four databases is state-of-the-art, which also presents the high robustness of the proposed approach. This successful result has not only contributed to the area of automated retinal blood vessel segmentation but also supports the effectiveness of transfer learning when applying deep learning technique to medical imaging. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Optic disk localization by a robust fusion method

    NASA Astrophysics Data System (ADS)

    Zhang, Jielin; Yin, Fengshou; Wong, Damon W. K.; Liu, Jiang; Baskaran, Mani; Cheng, Ching-Yu; Wong, Tien Yin

    2013-02-01

    The optic disk localization plays an important role in developing computer-aided diagnosis (CAD) systems for ocular diseases such as glaucoma, diabetic retinopathy and age-related macula degeneration. In this paper, we propose an intelligent fusion of methods for the localization of the optic disk in retinal fundus images. Three different approaches are developed to detect the location of the optic disk separately. The first method is the maximum vessel crossing method, which finds the region with the most number of blood vessel crossing points. The second one is the multichannel thresholding method, targeting the area with the highest intensity. The final method searches the vertical and horizontal region-of-interest separately on the basis of blood vessel structure and neighborhood entropy profile. Finally, these three methods are combined using an intelligent fusion method to improve the overall accuracy. The proposed algorithm was tested on the STARE database and the ORIGAlight database, each consisting of images with various pathologies. The preliminary result on the STARE database can achieve 81.5%, while a higher result of 99% can be obtained for the ORIGAlight database. The proposed method outperforms each individual approach and state-of-the-art method which utilizes an intensity-based approach. The result demonstrates a high potential for this method to be used in retinal CAD systems.

  16. U.S. Coast Guard SARSAT Final Evaluation Report. Volume I. Technical Evaluation.

    DOT National Transportation Integrated Search

    1987-03-01

    This volume presents the findings of the U.S. Coast Guard's two year demonstration and evaluation (D&E) of the COSPAS/SARSAT satellite aided search and rescue system for locating distressed vessels and aircraft, a cooperative project of the US, USSR,...

  17. Vessel discoloration detection in malarial retinopathy

    NASA Astrophysics Data System (ADS)

    Agurto, C.; Nemeth, S.; Barriga, S.; Soliz, P.; MacCormick, I.; Taylor, T.; Harding, S.; Lewallen, S.; Joshi, V.

    2016-03-01

    Cerebral malaria (CM) is a life-threatening clinical syndrome associated with malarial infection. It affects approximately 200 million people, mostly sub-Saharan African children under five years of age. Malarial retinopathy (MR) is a condition in which lesions such as whitening and vessel discoloration that are highly specific to CM appear in the retina. Other unrelated diseases can present with symptoms similar to CM, therefore the exact nature of the clinical symptoms must be ascertained in order to avoid misdiagnosis, which can lead to inappropriate treatment and, potentially, death. In this paper we outline the first system to detect the presence of discolored vessels associated with MR as a means to improve the CM diagnosis. We modified and improved our previous vessel segmentation algorithm by incorporating the `a' channel of the CIELab color space and noise reduction. We then divided the segmented vasculature into vessel segments and extracted features at the wall and in the centerline of the segment. Finally, we used a regression classifier to sort the segments into discolored and not-discolored vessel classes. By counting the abnormal vessel segments in each image, we were able to divide the analyzed images into two groups: normal and presence of vessel discoloration due to MR. We achieved an accuracy of 85% with sensitivity of 94% and specificity of 67%. In clinical practice, this algorithm would be combined with other MR retinal pathology detection algorithms. Therefore, a high specificity can be achieved. By choosing a different operating point in the ROC curve, our system achieved sensitivity of 67% with specificity of 100%.

  18. Integrating Multiple Autonomous Underwater Vessels, Surface Vessels and Aircraft into Oceanographic Research Vessel Operations

    NASA Astrophysics Data System (ADS)

    McGillivary, P. A.; Borges de Sousa, J.; Martins, R.; Rajan, K.

    2012-12-01

    Autonomous platforms are increasingly used as components of Integrated Ocean Observing Systems and oceanographic research cruises. Systems deployed can include gliders or propeller-driven autonomous underwater vessels (AUVs), autonomous surface vessels (ASVs), and unmanned aircraft systems (UAS). Prior field campaigns have demonstrated successful communication, sensor data fusion and visualization for studies using gliders and AUVs. However, additional requirements exist for incorporating ASVs and UASs into ship operations. For these systems to be optimally integrated into research vessel data management and operational planning systems involves addressing three key issues: real-time field data availability, platform coordination, and data archiving for later analysis. A fleet of AUVs, ASVs and UAS deployed from a research vessel is best operated as a system integrated with the ship, provided communications among them can be sustained. For this purpose, Disruptive Tolerant Networking (DTN) software protocols for operation in communication-challenged environments help ensure reliable high-bandwidth communications. Additionally, system components need to have considerable onboard autonomy, namely adaptive sampling capabilities using their own onboard sensor data stream analysis. We discuss Oceanographic Decision Support System (ODSS) software currently used for situational awareness and planning onshore, and in the near future event detection and response will be coordinated among multiple vehicles. Results from recent field studies from oceanographic research vessels using AUVs, ASVs and UAS, including the Rapid Environmental Picture (REP-12) cruise, are presented describing methods and results for use of multi-vehicle communication and deliberative control networks, adaptive sampling with single and multiple platforms, issues relating to data management and archiving, and finally challenges that remain in addressing these technological issues. Significantly, the use of UAS on oceanographic research vessels is just beginning. We report on several initial field efforts which demonstrated that UAS improve spatial and temporal mapping of ocean features, as well as monitoring marine mammal populations, ocean color, sea ice and wave fields and air-sea gas exchange. These studies however also confirm the challenges for shipboard computer systems ingesting and archiving UAS high resolution video, SAR and lidar data. We describe the successful inclusion of DTN communications for: 1) passing video data between two UAS or a UAS and ship; 2) for inclusion of ASVs as communication nodes for AUVs; as well as, 3) enabling extension of adaptive sampling software from AUVs and ASVs to include UAS. In conclusion, we describe how autonomous sampling systems may be best integrated into shipboard oceanographic vessel research to provide new and more comprehensive time-space ocean and atmospheric data collection that is important not only for scientific study, but also for sustainable ocean management, including emergency response capabilities. The recent examples of such integrated studies highlighted confirm ocean and atmospheric studies can more cost-effectively pursued, and in some cases only accomplished, by combining underwater, surface and aircraft autonomous systems with research vessel operations.

  19. U.S. Coast Guard SARSAT Final Evaluation Report. Volume III. Programs and Data Listings.

    DOT National Transportation Integrated Search

    1987-04-01

    Volume I of this report, Technical Evaluation, presents the findings of the U.S. Coast Guard's two year demonstration and evaluation (D&E) of the COSPAS/SARSAT satellite-aided search and rescue system for locating distressed vessels and aircraft, a c...

  20. From forager tracks to prey distributions: an application to tuna vessel monitoring systems (VMS).

    PubMed

    Walker, Emily; Rivoirard, Jacques; Gaspar, Philippe; Bez, Nicolas

    2015-04-01

    In the open ocean, movements of migratory fish populations are typically surveyed using tagging methods that are subject to low sample sizes for archive tags, except for a few notable examples, and poor temporal resolution for conventional tags. Alternatively, one can infer patterns of movement of migratory fish by tracking movements of their predators, i.e., fishing vessels, whose navigational systems (e.g., GPS) provide accurate and frequent VMS (vessel monitoring system) records of movement in pursuit of prey. In this paper, we develop a state-space model that infers the foraging activities of fishing vessels from their tracks. Second, we link foraging activities to probabilities of tuna presence. Finally, using multivariate geostatistical interpolation (cokriging) we map the probability of tuna presence together with their estimation variances and produce a time series of indices of abundance. While the segmentation of the trajectories is validated by observers' data, the present VMS-index is compared to catch rate and proved to be useful for management perspectives. The approach reported in this manuscript extends beyond the case study considered. It can be applied to any foragers that engage in an attempt of capture when they see prey and for whom this attempt is linked to a tractable change in behavior.

  1. 77 FR 40521 - Security Zones, Seattle's Seafair Fleet Week Moving Vessels, Puget Sound, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-10

    ... 1625-AA87 Security Zones, Seattle's Seafair Fleet Week Moving Vessels, Puget Sound, WA AGENCY: Coast Guard, DHS. ACTION: Final rule. SUMMARY: The U.S. Coast Guard is establishing security zones around designated participating vessels that are not protected by the Naval Vessel Protection Zone in Seattle's...

  2. 75 FR 54025 - Vessel and Facility Response Plans for Oil: 2003 Removal Equipment Requirements and Alternative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-03

    ...-AA26 Vessel and Facility Response Plans for Oil: 2003 Removal Equipment Requirements and Alternative... a final rule entitled ``Vessel and Facility Response Plans for Oil: 2003 Removal Equipment... responders for each vessel or facility with appropriate equipment and resources located in each zone of...

  3. Non-Axisymmetric Inflatable Pressure Structure (NAIPS) Concept that Enables Mass Efficient Packageable Pressure Vessels with Sealable Openings

    NASA Technical Reports Server (NTRS)

    Doggett, William R.; Jones, Thomas C.; Kenner, Winfred S.; Moore, David F.; Watson, Judith J.; Warren, Jerry E.; Makino, Alberto; Yount, Bryan; Selig, Molly; Shariff, Khadijah; hide

    2016-01-01

    Achieving minimal launch volume and mass are always important for space missions, especially for deep space manned missions where the costs required to transport mass to the destination are high and volume in the payload shroud is limited. Pressure vessels are used for many purposes in space missions including habitats, airlocks, and tank farms for fuel or processed resources. A lucrative approach to minimize launch volume is to construct the pressure vessels from soft goods so that they can be compactly packaged for launch and then inflated en route or at the final destination. In addition, there is the potential to reduce system mass because the packaged pressure vessels are inherently robust to launch loads and do not need to be modified from their in-service configuration to survive the launch environment. A novel concept is presented herein, in which sealable openings or hatches into the pressure vessels can also be fabricated from soft goods. To accomplish this, the structural shape is designed to have large regions where one principal stress is near zero. The pressure vessel is also required to have an elongated geometry for applications such as airlocks.

  4. Tracking control of a marine surface vessel with full-state constraints

    NASA Astrophysics Data System (ADS)

    Yin, Zhao; He, Wei; Yang, Chenguang

    2017-02-01

    In this paper, a trajectory tracking control law is proposed for a class of marine surface vessels in the presence of full-state constraints and dynamics uncertainties. A barrier Lyapunov function (BLF) based control is employed to prevent states from violating the constraints. Neural networks are used to approximate the system uncertainties in the control design, and the control law is designed by using the Moore-Penrose inverse. The proposed control is able to compensate for the effects of full-state constraints. Meanwhile, the signals in the closed-loop system are guaranteed to be semiglobally uniformly bounded, with the asymptotic tracking being achieved. Finally, the performance of the proposed control has been tested and verified by simulation studies.

  5. Assessment of microcirculation dynamics during cutaneous wound healing phases in vivo using optical microangiography

    PubMed Central

    Yousefi, Siavash; Qin, Jia; Dziennis, Suzan; Wang, Ruikang K.

    2014-01-01

    Abstract. Cutaneous wound healing consists of multiple overlapping phases starting with blood coagulation following incision of blood vessels. We utilized label-free optical coherence tomography and optical microangiography (OMAG) to noninvasively monitor healing process and dynamics of microcirculation system in a mouse ear pinna wound model. Mouse ear pinna is composed of two layers of skin separated by a layer of cartilage and because its total thickness is around 500 μm, it can be utilized as an ideal model for optical imaging techniques. These skin layers are identical to human skin structure except for sweat ducts and glands. Microcirculatory system responds to the wound injury by recruiting collateral vessels to supply blood flow to hypoxic region. During the inflammatory phase, lymphatic vessels play an important role in the immune response of the tissue and clearing waste from interstitial fluid. In the final phase of wound healing, tissue maturation, and remodeling, the wound area is fully closed while blood vessels mature to support the tissue cells. We show that using OMAG technology allows noninvasive and label-free monitoring and imaging each phase of wound healing that can be used to replace invasive tissue sample histology and immunochemistry technologies. PMID:25036212

  6. Vessel segmentation in 3D spectral OCT scans of the retina

    NASA Astrophysics Data System (ADS)

    Niemeijer, Meindert; Garvin, Mona K.; van Ginneken, Bram; Sonka, Milan; Abràmoff, Michael D.

    2008-03-01

    The latest generation of spectral optical coherence tomography (OCT) scanners is able to image 3D cross-sectional volumes of the retina at a high resolution and high speed. These scans offer a detailed view of the structure of the retina. Automated segmentation of the vessels in these volumes may lead to more objective diagnosis of retinal vascular disease including hypertensive retinopathy, retinopathy of prematurity. Additionally, vessel segmentation can allow color fundus images to be registered to these 3D volumes, possibly leading to a better understanding of the structure and localization of retinal structures and lesions. In this paper we present a method for automatically segmenting the vessels in a 3D OCT volume. First, the retina is automatically segmented into multiple layers, using simultaneous segmentation of their boundary surfaces in 3D. Next, a 2D projection of the vessels is produced by only using information from certain segmented layers. Finally, a supervised, pixel classification based vessel segmentation approach is applied to the projection image. We compared the influence of two methods for the projection on the performance of the vessel segmentation on 10 optic nerve head centered 3D OCT scans. The method was trained on 5 independent scans. Using ROC analysis, our proposed vessel segmentation system obtains an area under the curve of 0.970 when compared with the segmentation of a human observer.

  7. 76 FR 82117 - Regulations Implementing the Longshore and Harbor Workers' Compensation Act: Recreational Vessels

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-30

    ...This final rule contains regulations implementing amendments to the Longshore and Harbor Workers' Compensation Act (LHWCA) by the American Recovery and Reinvestment Act of 2009 (ARRA), relating to the exclusion of certain recreational-vessel workers from the LHWCA's definition of ``employee.'' These regulations clarify both the definition of ``recreational vessel'' and those circumstances under which workers are excluded from LHWCA coverage when working on those vessels. The final rule also withdraws a proposed rule that would have codified current case law and the Department's longstanding view that employees are covered under the LHWCA so long as some of their work constitutes ``maritime employment'' within the meaning of the statute.

  8. 76 FR 31351 - Safety Requirements and Manning Exemption Eligibility on Distant Water Tuna Fleet Vessels

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-31

    ...The Coast Guard announces the availability of Office of Vessel Activities Policy Letter 11-05 regarding Distant Water Tuna Fleet vessels manning exemption eligibility and safety requirements. This final policy clarifies the requirements to allow a distant water tuna fleet vessel to engage foreign citizens under a temporary manning exemption.

  9. Superficial vessel reconstruction with a multiview camera system

    PubMed Central

    Marreiros, Filipe M. M.; Rossitti, Sandro; Karlsson, Per M.; Wang, Chunliang; Gustafsson, Torbjörn; Carleberg, Per; Smedby, Örjan

    2016-01-01

    Abstract. We aim at reconstructing superficial vessels of the brain. Ultimately, they will serve to guide the deformation methods to compensate for the brain shift. A pipeline for three-dimensional (3-D) vessel reconstruction using three mono-complementary metal-oxide semiconductor cameras has been developed. Vessel centerlines are manually selected in the images. Using the properties of the Hessian matrix, the centerline points are assigned direction information. For correspondence matching, a combination of methods was used. The process starts with epipolar and spatial coherence constraints (geometrical constraints), followed by relaxation labeling and an iterative filtering where the 3-D points are compared to surfaces obtained using the thin-plate spline with decreasing relaxation parameter. Finally, the points are shifted to their local centroid position. Evaluation in virtual, phantom, and experimental images, including intraoperative data from patient experiments, shows that, with appropriate camera positions, the error estimates (root-mean square error and mean error) are ∼1  mm. PMID:26759814

  10. A Morphological Hessian Based Approach for Retinal Blood Vessels Segmentation and Denoising Using Region Based Otsu Thresholding

    PubMed Central

    BahadarKhan, Khan; A Khaliq, Amir; Shahid, Muhammad

    2016-01-01

    Diabetic Retinopathy (DR) harm retinal blood vessels in the eye causing visual deficiency. The appearance and structure of blood vessels in retinal images play an essential part in the diagnoses of an eye sicknesses. We proposed a less computational unsupervised automated technique with promising results for detection of retinal vasculature by using morphological hessian based approach and region based Otsu thresholding. Contrast Limited Adaptive Histogram Equalization (CLAHE) and morphological filters have been used for enhancement and to remove low frequency noise or geometrical objects, respectively. The hessian matrix and eigenvalues approach used has been in a modified form at two different scales to extract wide and thin vessel enhanced images separately. Otsu thresholding has been further applied in a novel way to classify vessel and non-vessel pixels from both enhanced images. Finally, postprocessing steps has been used to eliminate the unwanted region/segment, non-vessel pixels, disease abnormalities and noise, to obtain a final segmented image. The proposed technique has been analyzed on the openly accessible DRIVE (Digital Retinal Images for Vessel Extraction) and STARE (STructured Analysis of the REtina) databases along with the ground truth data that has been precisely marked by the experts. PMID:27441646

  11. Near Real-Time Automatic Marine Vessel Detection on Optical Satellite Images

    NASA Astrophysics Data System (ADS)

    Máttyus, G.

    2013-05-01

    Vessel monitoring and surveillance is important for maritime safety and security, environment protection and border control. Ship monitoring systems based on Synthetic-aperture Radar (SAR) satellite images are operational. On SAR images the ships made of metal with sharp edges appear as bright dots and edges, therefore they can be well distinguished from the water. Since the radar is independent from the sun light and can acquire images also by cloudy weather and rain, it provides a reliable service. Vessel detection from spaceborne optical images (VDSOI) can extend the SAR based systems by providing more frequent revisit times and overcoming some drawbacks of the SAR images (e.g. lower spatial resolution, difficult human interpretation). Optical satellite images (OSI) can have a higher spatial resolution thus enabling the detection of smaller vessels and enhancing the vessel type classification. The human interpretation of an optical image is also easier than as of SAR image. In this paper I present a rapid automatic vessel detection method which uses pattern recognition methods, originally developed in the computer vision field. In the first step I train a binary classifier from image samples of vessels and background. The classifier uses simple features which can be calculated very fast. For the detection the classifier is slided along the image in various directions and scales. The detector has a cascade structure which rejects most of the background in the early stages which leads to faster execution. The detections are grouped together to avoid multiple detections. Finally the position, size(i.e. length and width) and heading of the vessels is extracted from the contours of the vessel. The presented method is parallelized, thus it runs fast (in minutes for 16000 × 16000 pixels image) on a multicore computer, enabling near real-time applications, e.g. one hour from image acquisition to end user.

  12. 75 FR 750 - Consumer Price Index Adjustments of Oil Pollution Act of 1990 Limits of Liability-Vessels and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-06

    ... applicability of the OPA 90 single-hull tank vessel limits of liability. DATES: This final rule is effective... amendments to clarify the applicability of the single-hull tank vessel limits of liability, and solicited... regulations, at 33 CFR part 138, subpart A, to single- hull tank vessels that do not carry oil as cargo. As...

  13. 46 CFR 171.080 - Damage stability standards for vessels with Type I or Type II subdivision.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... following conditions in the final stage of flooding: (1) On a vessel required to survive assumed damage with... in the final stage of flooding and to meet the conditions set forth in paragraphs (f) (8) and (9) of this section in each intermediate stage of flooding. For the purposes of establishing boundaries to...

  14. 46 CFR 171.080 - Damage stability standards for vessels with Type I or Type II subdivision.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... following conditions in the final stage of flooding: (1) On a vessel required to survive assumed damage with... in the final stage of flooding and to meet the conditions set forth in paragraphs (f) (8) and (9) of this section in each intermediate stage of flooding. For the purposes of establishing boundaries to...

  15. 46 CFR 171.080 - Damage stability standards for vessels with Type I or Type II subdivision.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... following conditions in the final stage of flooding: (1) On a vessel required to survive assumed damage with... in the final stage of flooding and to meet the conditions set forth in paragraphs (f) (8) and (9) of this section in each intermediate stage of flooding. For the purposes of establishing boundaries to...

  16. 76 FR 78253 - New York State Prohibition of Discharges of Vessel Sewage; Final Affirmative Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-16

    ... holding tank, to a municipal wastewater treatment plant or to an on-site septic system. With 37 pumpouts... and install holding tanks for effluent. Such retrofitting is complicated due to the extremely limited... Sanitation Device (MSD) can be converted to a Type III MSD, commonly called a holding tank, which can be...

  17. Genetic algorithm based feature selection combined with dual classification for the automated detection of proliferative diabetic retinopathy.

    PubMed

    Welikala, R A; Fraz, M M; Dehmeshki, J; Hoppe, A; Tah, V; Mann, S; Williamson, T H; Barman, S A

    2015-07-01

    Proliferative diabetic retinopathy (PDR) is a condition that carries a high risk of severe visual impairment. The hallmark of PDR is the growth of abnormal new vessels. In this paper, an automated method for the detection of new vessels from retinal images is presented. This method is based on a dual classification approach. Two vessel segmentation approaches are applied to create two separate binary vessel map which each hold vital information. Local morphology features are measured from each binary vessel map to produce two separate 4-D feature vectors. Independent classification is performed for each feature vector using a support vector machine (SVM) classifier. The system then combines these individual outcomes to produce a final decision. This is followed by the creation of additional features to generate 21-D feature vectors, which feed into a genetic algorithm based feature selection approach with the objective of finding feature subsets that improve the performance of the classification. Sensitivity and specificity results using a dataset of 60 images are 0.9138 and 0.9600, respectively, on a per patch basis and 1.000 and 0.975, respectively, on a per image basis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Brain vascular image enhancement based on gradient adjust with split Bregman

    NASA Astrophysics Data System (ADS)

    Liang, Xiao; Dong, Di; Hui, Hui; Zhang, Liwen; Fang, Mengjie; Tian, Jie

    2016-04-01

    Light Sheet Microscopy is a high-resolution fluorescence microscopic technique which enables to observe the mouse brain vascular network clearly with immunostaining. However, micro-vessels are stained with few fluorescence antibodies and their signals are much weaker than large vessels, which make micro-vessels unclear in LSM images. In this work, we developed a vascular image enhancement method to enhance micro-vessel details which should be useful for vessel statistics analysis. Since gradient describes the edge information of the vessel, the main idea of our method is to increase the gradient values of the enhanced image to improve the micro-vessels contrast. Our method contained two steps: 1) calculate the gradient image of LSM image, and then amplify high gradient values of the original image to enhance the vessel edge and suppress low gradient values to remove noises. Then we formulated a new L1-norm regularization optimization problem to find an image with the expected gradient while keeping the main structure information of the original image. 2) The split Bregman iteration method was used to deal with the L1-norm regularization problem and generate the final enhanced image. The main advantage of the split Bregman method is that it has both fast convergence and low memory cost. In order to verify the effectiveness of our method, we applied our method to a series of mouse brain vascular images acquired from a commercial LSM system in our lab. The experimental results showed that our method could greatly enhance micro-vessel edges which were unclear in the original images.

  19. Assessment of vinyl polysiloxane as an innovative injection material for the anatomical study of vasculature.

    PubMed

    Dargaud, Jacques; Chalvet, Laurane; Del Corso, Marco; Cerboni, Elsa; Feugier, Patrick; Mertens, Patrick; Simon, Emile

    2016-04-01

    There are numerous injection materials for the study of vasculature in anatomical specimens, each having its own advantages and disadvantages. Latex and resins are the most widely used injection materials but need several days to set. The development of new materials taking shorter time to polymerize might be very useful to improve anatomic specimen study conditions. The aim of the present study was to evaluate vinyl polysiloxane (VPS), a silicon material widely used for dental impressions with the advantage to set very rapidly, as an injection material. We assessed the preparation, use, diffusion and setting time of the product in different anatomical regions (central nervous system, external carotid/jugular, lower limb) to observe its behavior in variably sized vessels. Our results suggest that VPS might be of interest for the study of vessels in anatomical specimens. The main strengths of the product are represented by (1) simplicity of use, as it is a ready-to-use material, (2) very rapid polymerization, (3) availability in a range of viscosities making easier the exploration of small vessels, (4) its better elasticity compared to resins, (5) and finally its availability in a range of colors making it a material of choice for vascular system dissections including those with very small caliber vessels.

  20. 75 FR 61771 - Notice of Public Availability of Navigation and Vessel Inspection Circular (NVIC) 2-10, “Guidance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-06

    ... Enforcement of the Salvage and Marine Firefighting Regulations for Vessel Response Plans'' AGENCY: Coast Guard... Response Plans. The guidance contained in the NVIC provides details regarding the application and enforcement of the final rule, ``Salvage and Marine Firefighting Requirements; Vessel Response Plans for Oil...

  1. 77 FR 71871 - Information Collection Available for Public Comments and Recommendations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-04

    ... availability, location, and specifications of U.S.-flag vessels for the purpose of making vessel availability... Administrator to make a timely and informed decision on the availability of coastwise qualified vessels in support of a request from the Department of Homeland Security prior to the final decision on granting a...

  2. Quantification of pulmonary vessel diameter in low-dose CT images

    NASA Astrophysics Data System (ADS)

    Rudyanto, Rina D.; Ortiz de Solórzano, Carlos; Muñoz-Barrutia, Arrate

    2015-03-01

    Accurate quantification of vessel diameter in low-dose Computer Tomography (CT) images is important to study pulmonary diseases, in particular for the diagnosis of vascular diseases and the characterization of morphological vascular remodeling in Chronic Obstructive Pulmonary Disease (COPD). In this study, we objectively compare several vessel diameter estimation methods using a physical phantom. Five solid tubes of differing diameters (from 0.898 to 3.980 mm) were embedded in foam, simulating vessels in the lungs. To measure the diameters, we first extracted the vessels using either of two approaches: vessel enhancement using multi-scale Hessian matrix computation, or explicitly segmenting them using intensity threshold. We implemented six methods to quantify the diameter: three estimating diameter as a function of scale used to calculate the Hessian matrix; two calculating equivalent diameter from the crosssection area obtained by thresholding the intensity and vesselness response, respectively; and finally, estimating the diameter of the object using the Full Width Half Maximum (FWHM). We find that the accuracy of frequently used methods estimating vessel diameter from the multi-scale vesselness filter depends on the range and the number of scales used. Moreover, these methods still yield a significant error margin on the challenging estimation of the smallest diameter (on the order or below the size of the CT point spread function). Obviously, the performance of the thresholding-based methods depends on the value of the threshold. Finally, we observe that a simple adaptive thresholding approach can achieve a robust and accurate estimation of the smallest vessels diameter.

  3. Prospects for the Thomson scattering system on NSTX-Upgrade.

    PubMed

    Diallo, A; LeBlanc, B P; Labik, G; Stevens, D

    2012-10-01

    The paper discusses the projected configuration of the Thomson system on the National Spherical Torus Experiment (NSTX-U). In this paper, we discuss the projected configuration of the Thomson system on NSTX-U. More specifically, we determine, through both optical modeling of the collection optics and in-vessel measurements, that the collecting fibers are to be displaced by at most 1 cm toward the imaging plane along the optical axis. Finally, we estimate the performance of the Thomson system in measuring the electron temperature for NSTX-U discharges.

  4. Case Analysis Of The Joint High Speed Vessel Program: Defense Acquisition

    DTIC Science & Technology

    2016-09-01

    reviews resulted in a series of Advanced Concept Technology Demonstrations (ACTD) designed to explore the military utility of converted commercial...requirements into a final and unique materiel solution for a system capability that is fielded. 14. SUBJECT TERMS Advanced Concept and Technology ...Advanced Concept Technology Demonstrations (ACTD) designed to explore the military utility of converted commercial, high-speed, shallow-draft

  5. 78 FR 34255 - Regulated Navigation Area; Vessel Traffic in Vicinity of Marseilles Dam; Illinois River

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-07

    ...-0300 prior to processing through Lock and Dams within the RNA as follows: (i) Northbound vessels must... Navigation Area (RNA) on the Illinois River. This Temporary Final Rule stipulates operational requirements... Mile Marker 240.0 to Mile Marker 271.4. This RNA is necessary to protect the general public, vessels...

  6. Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jambon, E.; Petitpierre, F.; Brizzi, V.

    PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomesmore » and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.« less

  7. Pulmonary vessel segmentation utilizing curved planar reformation and optimal path finding (CROP) in computed tomographic pulmonary angiography (CTPA) for CAD applications

    NASA Astrophysics Data System (ADS)

    Zhou, Chuan; Chan, Heang-Ping; Kuriakose, Jean W.; Chughtai, Aamer; Wei, Jun; Hadjiiski, Lubomir M.; Guo, Yanhui; Patel, Smita; Kazerooni, Ella A.

    2012-03-01

    Vessel segmentation is a fundamental step in an automated pulmonary embolism (PE) detection system. The purpose of this study is to improve the segmentation scheme for pulmonary vessels affected by PE and other lung diseases. We have developed a multiscale hierarchical vessel enhancement and segmentation (MHES) method for pulmonary vessel tree extraction based on the analysis of eigenvalues of Hessian matrices. However, it is difficult to segment the pulmonary vessels accurately under suboptimal conditions, such as vessels occluded by PEs, surrounded by lymphoid tissues or lung diseases, and crossing with other vessels. In this study, we developed a new vessel refinement method utilizing curved planar reformation (CPR) technique combined with optimal path finding method (MHES-CROP). The MHES segmented vessels straightened in the CPR volume was refined using adaptive gray level thresholding where the local threshold was obtained from least-square estimation of a spline curve fitted to the gray levels of the vessel along the straightened volume. An optimal path finding method based on Dijkstra's algorithm was finally used to trace the correct path for the vessel of interest. Two and eight CTPA scans were randomly selected as training and test data sets, respectively. Forty volumes of interest (VOIs) containing "representative" vessels were manually segmented by a radiologist experienced in CTPA interpretation and used as reference standard. The results show that, for the 32 test VOIs, the average percentage volume error relative to the reference standard was improved from 32.9+/-10.2% using the MHES method to 9.9+/-7.9% using the MHES-CROP method. The accuracy of vessel segmentation was improved significantly (p<0.05). The intraclass correlation coefficient (ICC) of the segmented vessel volume between the automated segmentation and the reference standard was improved from 0.919 to 0.988. Quantitative comparison of the MHES method and the MHES-CROP method with the reference standard was also evaluated by the Bland-Altman plot. This preliminary study indicates that the MHES-CROP method has the potential to improve PE detection.

  8. Vessel Enhancement and Segmentation of 4D CT Lung Image Using Stick Tensor Voting

    NASA Astrophysics Data System (ADS)

    Cong, Tan; Hao, Yang; Jingli, Shi; Xuan, Yang

    2016-12-01

    Vessel enhancement and segmentation plays a significant role in medical image analysis. This paper proposes a novel vessel enhancement and segmentation method for 4D CT lung image using stick tensor voting algorithm, which focuses on addressing the vessel distortion issue of vessel enhancement diffusion (VED) method. Furthermore, the enhanced results are easily segmented using level-set segmentation. In our method, firstly, vessels are filtered using Frangi's filter to reduce intrapulmonary noises and extract rough blood vessels. Secondly, stick tensor voting algorithm is employed to estimate the correct direction along the vessel. Then the estimated direction along the vessel is used as the anisotropic diffusion direction of vessel in VED algorithm, which makes the intensity diffusion of points locating at the vessel wall be consistent with the directions of vessels and enhance the tubular features of vessels. Finally, vessels can be extracted from the enhanced image by applying level-set segmentation method. A number of experiments results show that our method outperforms traditional VED method in vessel enhancement and results in satisfied segmented vessels.

  9. 78 FR 47716 - Final Guidance Regarding Voluntary Inspection of Vessels for Compliance With the Maritime Labour...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-06

    ... of a Part A (mandatory standards) and a Part B (non-mandatory guidelines). To date, the U.S... vessels from non-ratifying nations. As a result, a U.S. vessel that is not able to demonstrate voluntary compliance with the standards of the Convention may be at risk for Port State Control actions (including...

  10. An easy method to differentiate retinal arteries from veins by spectral domain optical coherence tomography: retrospective, observational case series

    PubMed Central

    2014-01-01

    Background Recently it was shown that retinal vessel diameters could be measured using spectral domain optical coherence tomography (OCT). It has also been suggested that retinal vessels manifest different features on spectral domain OCT (SD-OCT) depending on whether they are arteries or veins. Our study was aimed to present a reliable SD-OCT assisted method of differentiating retinal arteries from veins. Methods Patients who underwent circular OCT scans centred at the optic disc using a Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany) were retrospectively reviewed. Individual retinal vessels were identified on infrared reflectance (IR) images and given unique labels for subsequent grading. Vessel types (artery, vein or uncertain) assessed by IR and/or fluorescein angiography (FA) were referenced as ground truth. From OCT, presence/absence of the hyperreflective lower border reflectivity feature was assessed. Presence of this feature was considered indicative for retinal arteries and compared with the ground truth. Results A total of 452 vessels from 26 eyes of 18 patients were labelled and 398 with documented vessel type (302 by IR and 96 by FA only) were included in the study. Using SD-OCT, 338 vessels were assigned a final grade, of which, 86.4% (292 vessels) were classified correctly. Forty three vessels (15 arteries and 28 veins) that IR failed to differentiate were correctly classified by SD-OCT. When using only IR based ground truth for vessel type the SD-OCT based classification approach reached a sensitivity of 0.8758/0.9297, and a specificity of 0.9297/0.8758 for arteries/veins, respectively. Conclusion Our method was able to classify retinal arteries and veins with a commercially available SD-OCT alone, and achieved high classification performance. Paired with OCT based vessel measurements, our study has expanded the potential clinical implication of SD-OCT in evaluation of a variety of retinal and systemic vascular diseases. PMID:24884611

  11. Quantification of choroidal neovascularization vessel length using optical coherence tomography angiography

    NASA Astrophysics Data System (ADS)

    Gao, Simon S.; Liu, Li; Bailey, Steven T.; Flaxel, Christina J.; Huang, David; Li, Dengwang; Jia, Yali

    2016-07-01

    Quantification of choroidal neovascularization (CNV) as visualized by optical coherence tomography angiography (OCTA) may have importance clinically when diagnosing or tracking disease. Here, we present an automated algorithm to quantify the vessel skeleton of CNV as vessel length. Initial segmentation of the CNV on en face angiograms was achieved using saliency-based detection and thresholding. A level set method was then used to refine vessel edges. Finally, a skeleton algorithm was applied to identify vessel centerlines. The algorithm was tested on nine OCTA scans from participants with CNV and comparisons of the algorithm's output to manual delineation showed good agreement.

  12. PORT II

    NASA Technical Reports Server (NTRS)

    Muniz, Beau

    2009-01-01

    One unique project that the Prototype lab worked on was PORT I (Post-landing Orion Recovery Test). PORT is designed to test and develop the system and components needed to recover the Orion capsule once it splashes down in the ocean. PORT II is designated as a follow up to PORT I that will utilize a mock up pressure vessel that is spatially compar able to the final Orion capsule.

  13. 75 FR 29757 - New York State Prohibition of Discharges of Vessel Sewage; Final Affirmative Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-27

    ..., 4 dispose of wastes to an on-site septic system, 21 dispose to a holding tank and 62 dispose to a... and regulated septic tanks or holding tanks for transport to a sewage treatment plant. Online maps are... are in a No Discharge Zone. A Type III marine sanitation device (holding tank) is the only type that...

  14. Computation of water hammer protection of modernized pumping station

    NASA Astrophysics Data System (ADS)

    Himr, Daniel

    2014-03-01

    Pumping station supplies water for irrigation. Maximal capacity 2 × 1.2m3·s-1 became insufficient, thus it was upgraded to 2 × 2m3·s-1. Paper is focused on design of protection against water hammer in case of sudden pumps trip. Numerical simulation of the most dangerous case (when pumps are giving the maximal flow rate) showed that existing air vessels were not able to protect the system and it would be necessary to add new vessels. Special care was paid to influence of their connection to the main pipeline, because the resistance of the connection has a significant impact on the scale of pressure pulsations. Finally, the pump trip was performed to verify if the system worked correctly. The test showed that pressure pulsations are lower (better) than computation predicted. This discrepancy was further analysed.

  15. Comparison of retinal vessel measurements using adaptive optics scanning laser ophthalmoscopy and optical coherence tomography.

    PubMed

    Arichika, Shigeta; Uji, Akihito; Ooto, Sotaro; Muraoka, Yuki; Yoshimura, Nagahisa

    2016-05-01

    We compared adaptive optics scanning laser ophthalmoscopy (AOSLO) and optical coherence tomography (OCT) vessel caliber measurements. AOSLO videos were acquired from 28 volunteers with healthy eyes. Artery measurements were made 0.5-1 disc diameters away from the optic disc margin. Individual segmented retinal arterial caliber was measured in synchronization with cardiac pulsation and averaged to obtain final horizontal retinal arterial caliber (ACH) and horizontal retinal arterial lumen (ALH). All OCT images were obtained with the Spectralis OCT, a spectral-domain OCT system. Vertical retinal arterial caliber (ACV) and vertical retinal arterial lumen (ALV) were measured on the same artery measured with AOSLO. Measurements made with the two imaging systems were compared. Average ACH, measured with AOSLO, was 123.4 ± 11.2 and average ALH was 101.8 ± 10.2 µm. Average ACV, measured with OCT, was 125.5 ± 11.4 and average ALV was 99.1 ± 10.6 µm. Both arterial caliber (r = 0.767, p < 0.0001) and arterial lumen (r = 0.81, p < 0.0001) measurements were significantly correlated between imaging modalities. Additionally, ACH and ACV were not significantly different (p = 0.16). However, ALH measurements were significantly higher than ALV measurements (p = 0.03). Vessel measurements made with AOSLO and OCT were well correlated. Moreover, plasma is visible and distinguishable from the retinal vessel wall in AOSLO images but not in OCT images. Therefore, AOSLO may measure vessel width more precisely than OCT.

  16. Multiple strategies of oxygen supply in Drosophila malignancies identify tracheogenesis as a novel cancer hallmark.

    PubMed

    Grifoni, Daniela; Sollazzo, Manuela; Fontana, Elisabetta; Froldi, Francesca; Pession, Annalisa

    2015-03-12

    Angiogenesis is the term used to describe all the alterations in blood vessel growth induced by a tumour mass following hypoxic stress. The occurrence of multiple strategies of vessel recruitment favours drug resistance, greatly complicating the treatment of certain tumours. In Drosophila, oxygen is conveyed to the internal organs by the tracheal system, a closed tubular network whose role in cancer growth is so far unexplored. We found that, as observed in human cancers, Drosophila malignant cells suffer from oxygen shortage, release pro-tracheogenic factors, co-opt nearby vessels and get incorporated into the tracheal walls. We also found that the parallelisms observed in cellular behaviours are supported by genetic and molecular conservation. Finally, we identified a molecular circuitry associated with the differentiation of cancer cells into tracheal cells. In summary, our findings identify tracheogenesis as a novel cancer hallmark in Drosophila, further expanding the power of the fly model in cancer research.

  17. An automatic graph-based approach for artery/vein classification in retinal images.

    PubMed

    Dashtbozorg, Behdad; Mendonça, Ana Maria; Campilho, Aurélio

    2014-03-01

    The classification of retinal vessels into artery/vein (A/V) is an important phase for automating the detection of vascular changes, and for the calculation of characteristic signs associated with several systemic diseases such as diabetes, hypertension, and other cardiovascular conditions. This paper presents an automatic approach for A/V classification based on the analysis of a graph extracted from the retinal vasculature. The proposed method classifies the entire vascular tree deciding on the type of each intersection point (graph nodes) and assigning one of two labels to each vessel segment (graph links). Final classification of a vessel segment as A/V is performed through the combination of the graph-based labeling results with a set of intensity features. The results of this proposed method are compared with manual labeling for three public databases. Accuracy values of 88.3%, 87.4%, and 89.8% are obtained for the images of the INSPIRE-AVR, DRIVE, and VICAVR databases, respectively. These results demonstrate that our method outperforms recent approaches for A/V classification.

  18. Minimizing camera-eye optical aberrations during the 3D reconstruction of retinal structures

    NASA Astrophysics Data System (ADS)

    Aldana-Iuit, Javier; Martinez-Perez, M. Elena; Espinosa-Romero, Arturo; Diaz-Uribe, Rufino

    2010-05-01

    3D reconstruction of blood vessels is a powerful visualization tool for physicians, since it allows them to refer to qualitative representation of their subject of study. In this paper we propose a 3D reconstruction method of retinal vessels from fundus images. The reconstruction method propose herein uses images of the same retinal structure in epipolar geometry. Images are preprocessed by RISA system for segmenting blood vessels and obtaining feature points for correspondences. The correspondence points process is solved using correlation. The LMedS analysis and Graph Transformation Matching algorithm are used for outliers suppression. Camera projection matrices are computed with the normalized eight point algorithm. Finally, we retrieve 3D position of the retinal tree points by linear triangulation. In order to increase the power of visualization, 3D tree skeletons are represented by surfaces via generalized cylinders whose radius correspond to morphological measurements obtained by RISA. In this paper the complete calibration process including the fundus camera and the optical properties of the eye, the so called camera-eye system is proposed. On one hand, the internal parameters of the fundus camera are obtained by classical algorithms using a reference pattern. On the other hand, we minimize the undesirable efects of the aberrations induced by the eyeball optical system assuming that contact enlarging lens corrects astigmatism, spherical and coma aberrations are reduced changing the aperture size and eye refractive errors are suppressed adjusting camera focus during image acquisition. Evaluation of two self-calibration proposals and results of 3D blood vessel surface reconstruction are presented.

  19. Vascular labeling of the head and neck vessels: Technique, advantages and limitations.

    PubMed

    Gálvez, Alba; Caraballo, José-Leonardo; Manzanares-Céspedes, María-Cristina; Valdivia-Gandur, Iván; Figueiredo, Rui; Valmaseda-Castellón, Eduard

    2017-05-01

    Vascular staining techniques have been used to describe the vascular structures of several anatomic areas. However, few reports have described this procedure in the head and neck region. This paper describes a head and neck vascular labeling procedure, and describes some of the technical complications that may occur. Fifteen specimen cadaver heads were prepared. After drying the vascular system, the internal carotid arteries were ligated and a solution with latex and a gelling agent was injected into the internal carotid arteries and external jugular veins. Two different colors were employed to differentiate arteries from veins. A total of 60ml latex was injected into each blood vessel. Subsequently, the specimens were refrigerated at 5°C for a minimum of 24 hours. Finally, a dissection was performed to identify the venous and arterial systems of the maxillofacial region. In most specimens, correct identification of the vascular structures (lingual artery, pterigoyd plexus, and the major palatal arteries, among others) was possible. However, in three heads a major technical problem occurred (the latex remained liquid), making the dissection unfeasible. Other minor complications such as latex obstruction due to the presence of atheromas were found in two further specimens. The vascular labeling technique is a predictable, effective and simple method for analyzing the vascular system of the maxillofacial area in cadaveric studies, including vessels of reduced diameter or with an intraosseous course. This procedure can be especially useful to teach vascular anatomy to dental students and postgraduate residents. Key words: Blood vessels, vascular casting, vascular labeling, head and neck arteries, carotid arteries, jugular veins.

  20. 50 CFR 300.116 - Requirements for a vessel monitoring system for U.S. vessels.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... system for U.S. vessels. 300.116 Section 300.116 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED... vessel monitoring system for U.S. vessels. (a) Requirement for use. Within 30 days after NMFS publishes... for AMLR must ensure that such vessel has a NMFS-approved, operating VMS on board when on any fishing...

  1. 50 CFR 300.116 - Requirements for a vessel monitoring system for U.S. vessels.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... system for U.S. vessels. 300.116 Section 300.116 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED... vessel monitoring system for U.S. vessels. (a) Requirement for use. Within 30 days after NMFS publishes... for AMLR must ensure that such vessel has a NMFS-approved, operating VMS on board when on any fishing...

  2. 50 CFR 300.116 - Requirements for a vessel monitoring system for U.S. vessels.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... system for U.S. vessels. 300.116 Section 300.116 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED... vessel monitoring system for U.S. vessels. (a) Requirement for use. Within 30 days after NMFS publishes... for AMLR must ensure that such vessel has a NMFS-approved, operating VMS on board when on any fishing...

  3. 50 CFR 300.116 - Requirements for a vessel monitoring system for U.S. vessels.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... system for U.S. vessels. 300.116 Section 300.116 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED... vessel monitoring system for U.S. vessels. (a) Requirement for use. Within 30 days after NMFS publishes... for AMLR must ensure that such vessel has a NMFS-approved, operating VMS on board when on any fishing...

  4. 50 CFR 300.116 - Requirements for a vessel monitoring system for U.S. vessels.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... system for U.S. vessels. 300.116 Section 300.116 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED... vessel monitoring system for U.S. vessels. (a) Requirement for use. Within 30 days after NMFS publishes... for AMLR must ensure that such vessel has a NMFS-approved, operating VMS on board when on any fishing...

  5. Thermo-physics technical note No. 37: SNAP- 10A, Stainless Steel-316 vessel wall ablation. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montgomery, L.D.

    1964-12-07

    The altitudes and times of ablation have been determined for the SNAP-10A, SS-316 vessel wall reentering under various conditions. The results are confined to one typical location on the reactor and to one typical reentry trajectory. The location is the side wall of the vessel and the trajectory is the one used in NAA-SR-8303.

  6. Westinghouse Small Modular Reactor nuclear steam supply system design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Memmott, M. J.; Harkness, A. W.; Van Wyk, J.

    2012-07-01

    The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the first in a series of four papers which describe the design and functionality of the Westinghouse SMR. Also described in this series are the key drivers influencing the design of the Westinghouse SMR and the unique passive safety features of the Westinghouse SMR. Several critical motivators contributed to the development andmore » integration of the Westinghouse SMR design. These design driving motivators dictated the final configuration of the Westinghouse SMR to varying degrees, depending on the specific features under consideration. These design drivers include safety, economics, AP1000{sup R} reactor expertise and experience, research and development requirements, functionality of systems and components, size of the systems and vessels, simplicity of design, and licensing requirements. The Westinghouse SMR NSSS consists of an integral reactor vessel within a compact containment vessel. The core is located in the bottom of the reactor vessel and is composed of 89 modified Westinghouse 17x17 Robust Fuel Assemblies (RFA). These modified fuel assemblies have an active core length of only 2.4 m (8 ft) long, and the entirety of the core is encompassed by a radial reflector. The Westinghouse SMR core operates on a 24 month fuel cycle. The reactor vessel is approximately 24.4 m (80 ft) long and 3.7 m (12 ft) in diameter in order to facilitate standard rail shipping to the site. The reactor vessel houses hot and cold leg channels to facilitate coolant flow, control rod drive mechanisms (CRDM), instrumentation and cabling, an intermediate flange to separate flow and instrumentation and facilitate simpler refueling, a pressurizer, a straight tube, recirculating steam generator, and eight reactor coolant pumps (RCP). The containment vessel is 27.1 m (89 ft) long and 9.8 m (32 ft) in diameter, and is designed to withstand pressures up to 1.7 MPa (250 psi). It is completely submerged in a pool of water serving as a heat sink and radiation shield. Housed within the containment are four combined core makeup tanks (CMT)/passive residual heat removal (PRHR) heat exchangers, two in-containment pools (ICP), two ICP tanks and four valves which function as the automatic depressurization system (ADS). The PRHR heat exchangers are thermally connected to two different ultimate heat sink (UHS) tanks which provide transient cooling capabilities. (authors)« less

  7. A multiphase transitioning peptide hydrogel for suturing ultrasmall vessels

    NASA Astrophysics Data System (ADS)

    Smith, Daniel J.; Brat, Gabriel A.; Medina, Scott H.; Tong, Dedi; Huang, Yong; Grahammer, Johanna; Furtmüller, Georg J.; Oh, Byoung Chol; Nagy-Smith, Katelyn J.; Walczak, Piotr; Brandacher, Gerald; Schneider, Joel P.

    2016-01-01

    Many surgeries are complicated by the need to anastomose, or reconnect, micrometre-scale vessels. Although suturing remains the gold standard for anastomosing vessels, it is difficult to place sutures correctly through collapsed lumen, making the procedure prone to failure. Here, we report a multiphase transitioning peptide hydrogel that can be injected into the lumen of vessels to facilitate suturing. The peptide, which contains a photocaged glutamic acid, forms a solid-like gel in a syringe and can be shear-thin delivered to the lumen of collapsed vessels (where it distends the vessel) and the space between two vessels (where it is used to approximate the vessel ends). Suturing is performed directly through the gel. Light is used to initiate the final gel-sol phase transition that disrupts the hydrogel network, allowing the gel to be removed and blood flow to resume. This gel adds a new tool to the armamentarium for micro- and supermicrosurgical procedures.

  8. An Unsupervised Approach for Extraction of Blood Vessels from Fundus Images.

    PubMed

    Dash, Jyotiprava; Bhoi, Nilamani

    2018-04-26

    Pathological disorders may happen due to small changes in retinal blood vessels which may later turn into blindness. Hence, the accurate segmentation of blood vessels is becoming a challenging task for pathological analysis. This paper offers an unsupervised recursive method for extraction of blood vessels from ophthalmoscope images. First, a vessel-enhanced image is generated with the help of gamma correction and contrast-limited adaptive histogram equalization (CLAHE). Next, the vessels are extracted iteratively by applying an adaptive thresholding technique. At last, a final vessel segmented image is produced by applying a morphological cleaning operation. Evaluations are accompanied on the publicly available digital retinal images for vessel extraction (DRIVE) and Child Heart And Health Study in England (CHASE_DB1) databases using nine different measurements. The proposed method achieves average accuracies of 0.957 and 0.952 on DRIVE and CHASE_DB1 databases respectively.

  9. Pulse Jet Mixing Tests With Noncohesive Solids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, Perry A.; Bamberger, Judith A.; Enderlin, Carl W.

    2012-02-17

    This report summarizes results from pulse jet mixing (PJM) tests with noncohesive solids in Newtonian liquid. The tests were conducted during FY 2007 and 2008 to support the design of mixing systems for the Hanford Waste Treatment and Immobilization Plant (WTP). Tests were conducted at three geometric scales using noncohesive simulants, and the test data were used to develop models predicting two measures of mixing performance for full-scale WTP vessels. The models predict the cloud height (the height to which solids will be lifted by the PJM action) and the critical suspension velocity (the minimum velocity needed to ensure allmore » solids are suspended off the floor, though not fully mixed). From the cloud height, the concentration of solids at the pump inlet can be estimated. The predicted critical suspension velocity for lifting all solids is not precisely the same as the mixing requirement for 'disturbing' a sufficient volume of solids, but the values will be similar and closely related. These predictive models were successfully benchmarked against larger scale tests and compared well with results from computational fluid dynamics simulations. The application of the models to assess mixing in WTP vessels is illustrated in examples for 13 distinct designs and selected operational conditions. The values selected for these examples are not final; thus, the estimates of performance should not be interpreted as final conclusions of design adequacy or inadequacy. However, this work does reveal that several vessels may require adjustments to design, operating features, or waste feed properties to ensure confidence in operation. The models described in this report will prove to be valuable engineering tools to evaluate options as designs are finalized for the WTP. Revision 1 refines data sets used for model development and summarizes models developed since the completion of Revision 0.« less

  10. 77 FR 3771 - Notice of Issuance of Final Outer Continental Shelf Air Permit for Shell Offshore, Inc.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-25

    ... drilling vessels (the Transocean Deepwater Nautilus, the Noble Bully I or the Noble Bully II) and support vessels to conduct exploratory drilling for up to 150 days per year over five to ten years in multiple...

  11. Analysis of Fundus Fluorescein Angiogram Based on the Hessian Matrix of Directional Curvelet Sub-bands and Distance Regularized Level Set Evolution.

    PubMed

    Soltanipour, Asieh; Sadri, Saeed; Rabbani, Hossein; Akhlaghi, Mohammad Reza

    2015-01-01

    This paper presents a new procedure for automatic extraction of the blood vessels and optic disk (OD) in fundus fluorescein angiogram (FFA). In order to extract blood vessel centerlines, the algorithm of vessel extraction starts with the analysis of directional images resulting from sub-bands of fast discrete curvelet transform (FDCT) in the similar directions and different scales. For this purpose, each directional image is processed by using information of the first order derivative and eigenvalues obtained from the Hessian matrix. The final vessel segmentation is obtained using a simple region growing algorithm iteratively, which merges centerline images with the contents of images resulting from modified top-hat transform followed by bit plane slicing. After extracting blood vessels from FFA image, candidates regions for OD are enhanced by removing blood vessels from the FFA image, using multi-structure elements morphology, and modification of FDCT coefficients. Then, canny edge detector and Hough transform are applied to the reconstructed image to extract the boundary of candidate regions. At the next step, the information of the main arc of the retinal vessels surrounding the OD region is used to extract the actual location of the OD. Finally, the OD boundary is detected by applying distance regularized level set evolution. The proposed method was tested on the FFA images from angiography unit of Isfahan Feiz Hospital, containing 70 FFA images from different diabetic retinopathy stages. The experimental results show the accuracy more than 93% for vessel segmentation and more than 87% for OD boundary extraction.

  12. Analysis of Fundus Fluorescein Angiogram Based on the Hessian Matrix of Directional Curvelet Sub-bands and Distance Regularized Level Set Evolution

    PubMed Central

    Soltanipour, Asieh; Sadri, Saeed; Rabbani, Hossein; Akhlaghi, Mohammad Reza

    2015-01-01

    This paper presents a new procedure for automatic extraction of the blood vessels and optic disk (OD) in fundus fluorescein angiogram (FFA). In order to extract blood vessel centerlines, the algorithm of vessel extraction starts with the analysis of directional images resulting from sub-bands of fast discrete curvelet transform (FDCT) in the similar directions and different scales. For this purpose, each directional image is processed by using information of the first order derivative and eigenvalues obtained from the Hessian matrix. The final vessel segmentation is obtained using a simple region growing algorithm iteratively, which merges centerline images with the contents of images resulting from modified top-hat transform followed by bit plane slicing. After extracting blood vessels from FFA image, candidates regions for OD are enhanced by removing blood vessels from the FFA image, using multi-structure elements morphology, and modification of FDCT coefficients. Then, canny edge detector and Hough transform are applied to the reconstructed image to extract the boundary of candidate regions. At the next step, the information of the main arc of the retinal vessels surrounding the OD region is used to extract the actual location of the OD. Finally, the OD boundary is detected by applying distance regularized level set evolution. The proposed method was tested on the FFA images from angiography unit of Isfahan Feiz Hospital, containing 70 FFA images from different diabetic retinopathy stages. The experimental results show the accuracy more than 93% for vessel segmentation and more than 87% for OD boundary extraction. PMID:26284170

  13. Optic cup segmentation: type-II fuzzy thresholding approach and blood vessel extraction

    PubMed Central

    Almazroa, Ahmed; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2017-01-01

    We introduce here a new technique for segmenting optic cup using two-dimensional fundus images. Cup segmentation is the most challenging part of image processing of the optic nerve head due to the complexity of its structure. Using the blood vessels to segment the cup is important. Here, we report on blood vessel extraction using first a top-hat transform and Otsu’s segmentation function to detect the curves in the blood vessels (kinks) which indicate the cup boundary. This was followed by an interval type-II fuzzy entropy procedure. Finally, the Hough transform was applied to approximate the cup boundary. The algorithm was evaluated on 550 fundus images from a large dataset, which contained three different sets of images, where the cup was manually marked by six ophthalmologists. On one side, the accuracy of the algorithm was tested on the three image sets independently. The final cup detection accuracy in terms of area and centroid was calculated to be 78.2% of 441 images. Finally, we compared the algorithm performance with manual markings done by the six ophthalmologists. The agreement was determined between the ophthalmologists as well as the algorithm. The best agreement was between ophthalmologists one, two and five in 398 of 550 images, while the algorithm agreed with them in 356 images. PMID:28515636

  14. Optic cup segmentation: type-II fuzzy thresholding approach and blood vessel extraction.

    PubMed

    Almazroa, Ahmed; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2017-01-01

    We introduce here a new technique for segmenting optic cup using two-dimensional fundus images. Cup segmentation is the most challenging part of image processing of the optic nerve head due to the complexity of its structure. Using the blood vessels to segment the cup is important. Here, we report on blood vessel extraction using first a top-hat transform and Otsu's segmentation function to detect the curves in the blood vessels (kinks) which indicate the cup boundary. This was followed by an interval type-II fuzzy entropy procedure. Finally, the Hough transform was applied to approximate the cup boundary. The algorithm was evaluated on 550 fundus images from a large dataset, which contained three different sets of images, where the cup was manually marked by six ophthalmologists. On one side, the accuracy of the algorithm was tested on the three image sets independently. The final cup detection accuracy in terms of area and centroid was calculated to be 78.2% of 441 images. Finally, we compared the algorithm performance with manual markings done by the six ophthalmologists. The agreement was determined between the ophthalmologists as well as the algorithm. The best agreement was between ophthalmologists one, two and five in 398 of 550 images, while the algorithm agreed with them in 356 images.

  15. 78 FR 60099 - Nontank Vessel Response Plans and Other Response Plan Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-30

    ... Convention for the Prevention of Pollution From Ships MEPC Marine Environment Protection Committee NAICS... vessels to prepare and submit oil spill response plans. The Federal Water Pollution Control Act defines.... Additionally, this final rule updates the international Shipboard Oil Pollution Emergency Plan requirements...

  16. Gelling agents and culture vessels affect in vitro multiplication of banana plantlets.

    PubMed

    Kaçar, Y A; Biçen, B; Varol, I; Mendi, Y Y; Serçe, S; Cetiner, S

    2010-03-09

    Agar is the most commonly used gelling agent in media for plant tissue culture. Because of the high price of tissue-culture-grade agar, attempts have been made to identify suitable alternatives. The type of culture vessel and lid also affects the gaseous composition inside the vessel as well as light penetration. In turn, the vessel affects growth parameters, such as shoot elongation, proliferation and fresh weight, as well as hyperhydric degradation processes. We examined the effects of different culture vessels, including commercial glass jars, magenta boxes, and disposable containers, as well as different gelling agents (agar-agar, Agargel, Phytagel, and plant agar) on the micropropagation of Dwarf Cavendish bananas in an effort to find a combination that yields large numbers of high-quality seedlings. The different culture vessels did not significantly affect seedling culture success. The medium significantly affected shoot weight. Phytagel resulted in the highest shoot weight (overall mean = 2.4 g), while agar, Agargel and plant agar resulted in 1.7, 2.2 and 2.2 g, respectively. Disposable container/Phytagel and Magenta/Agargel combinations yielded the highest shoot weights (2.9 and 3.0 g, respectively). Mean shoot length increased progressively with subculture (four subcultures were made). The highest mean shoot length was obtained with Phytagel and Agargel media (6.4 and 6.3 cm, respectively). Shoot number was significantly affected by medium only at subculture 4. Overall, the highest mean shoot length was obtained with the Magenta/Agargel combination (8.5 cm). Phytagel and plant agar gave higher mean shoot number than agar and Agargel (2.1, 2.1 and 1.7 and 1.9, respectively). The costs of the media and of the culture vessels need to be taken into account for final choice of the banana shoot culture system.

  17. Seismic attenuation system for a nuclear reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liszkai, Tamas; Cadell, Seth

    A system for attenuating seismic forces includes a reactor pressure vessel containing nuclear fuel and a containment vessel that houses the reactor pressure vessel. Both the reactor pressure vessel and the containment vessel include a bottom head. Additionally, the system includes a base support to contact a support surface on which the containment vessel is positioned in a substantially vertical orientation. An attenuation device is located between the bottom head of the reactor pressure vessel and the bottom head of the containment vessel. Seismic forces that travel from the base support to the reactor pressure vessel via the containment vesselmore » are attenuated by the attenuation device in a direction that is substantially lateral to the vertical orientation of the containment vessel.« less

  18. Vessel V-7 and V-8 repair and characterization of insert material. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Domian, H.A.

    1984-05-01

    Pieces of Type SA508-2 steel, specially tempered to produce a high-impact-transition temperature, were welded in the side walls of Intermediate Test Vessels V-7 and V-8. These vessels are to be tested by the Oak Ridge National Laboratory (ORNL) in the Pressurized-Thermal-Shock (PTS) Project of the Heavy-Section Steel Technology (HSST) Program. A comparable piece of forging taken from the same source and heat treated with the vessels was characterized for its mechanical properties to provide data for use in the PTS tests.

  19. 33 CFR 157.116 - Required documents: U.S. tank vessels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels General § 157.116 Required documents: U.S. tank vessels. The owner, operator, and master of a U.S. tank vessel having a COW system under... COW system consisting of— (1) A document from an authorized CS that certifies the vessel meets § 157...

  20. 75 FR 8431 - Carbon Dioxide Fire Suppression Systems on Commercial Vessels

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-24

    ... Fire Suppression Systems on Commercial Vessels; Proposed Rule #0;#0;Federal Register / Vol. 75 , No. 36... 1625-AB44 Carbon Dioxide Fire Suppression Systems on Commercial Vessels AGENCY: Coast Guard, DHS... for fire suppression systems on several classes of commercial vessels. The amendments would clarify...

  1. 29 CFR 1915.85 - Vessel radar and communication systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Vessel radar and communication systems. 1915.85 Section... Working Conditions § 1915.85 Vessel radar and communication systems. (a) The employer shall service each vessel's radar and communication systems in accordance with 29 CFR 1915.89, Control of Hazardous Energy...

  2. 29 CFR 1915.85 - Vessel radar and communication systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Vessel radar and communication systems. 1915.85 Section... Working Conditions § 1915.85 Vessel radar and communication systems. (a) The employer shall service each vessel's radar and communication systems in accordance with 29 CFR 1915.89, Control of Hazardous Energy...

  3. 78 FR 58415 - Oil and Natural Gas Sector: Reconsideration of Certain Provisions of New Source Performance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-23

    ...). C. Group 1 Storage Vessel Affected Facility Control Requirements The final amendments retain the... Control Requirements and Applicability We received comments requesting clarification regarding Group 1... there was confusion regarding the applicability of Group 1 storage vessel affected facility control...

  4. 10 CFR 50.82 - Termination of license.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... to the NRC, consistent with the requirements of § 50.4(b)(8); (ii) Once fuel has been permanently... fuel from the reactor vessel, or when a final legally effective order to permanently cease operations... emplacement or retention of fuel into the reactor vessel. (3) Decommissioning will be completed within 60...

  5. 46 CFR 172.245 - Survival conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... conditions. A vessel is presumed to survive assumed damage if it meets the following conditions in the final..., and trim must be below the lower edge of an opening through which progressive flooding may take place... inches (50 mm) when the vessel is in the equilibrium position. (e) Progressive flooding. In the design...

  6. 46 CFR 172.245 - Survival conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... conditions. A vessel is presumed to survive assumed damage if it meets the following conditions in the final..., and trim must be below the lower edge of an opening through which progressive flooding may take place... inches (50 mm) when the vessel is in the equilibrium position. (e) Progressive flooding. In the design...

  7. 46 CFR 172.245 - Survival conditions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... conditions. A vessel is presumed to survive assumed damage if it meets the following conditions in the final..., and trim must be below the lower edge of an opening through which progressive flooding may take place... inches (50 mm) when the vessel is in the equilibrium position. (e) Progressive flooding. In the design...

  8. 76 FR 59660 - Proposed Information Collection; Comment Request; Permitting, Vessel Identification, and Vessel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-27

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration Proposed Information Collection; Comment Request; Permitting, Vessel Identification, and Vessel Monitoring System Requirements for... satellite- based vessel monitoring system (VMS). This collection of information is needed for permit...

  9. Overview of the Final 2013 VGP

    EPA Pesticide Factsheets

    This document is a brief overview of the final 2013 VGP that provides NPDES permit coverage nationwide for discharges incidental to the normal operation of commercial vessels greater than 79 feet in length.

  10. Use of Gabor filters and deep networks in the segmentation of retinal vessel morphology

    NASA Astrophysics Data System (ADS)

    Leopold, Henry A.; Orchard, Jeff; Zelek, John; Lakshminarayanan, Vasudevan

    2017-02-01

    The segmentation of retinal morphology has numerous applications in assessing ophthalmologic and cardiovascular disease pathologies. The early detection of many such conditions is often the most effective method for reducing patient risk. Computer aided segmentation of the vasculature has proven to be a challenge, mainly due to inconsistencies such as noise, variations in hue and brightness that can greatly reduce the quality of fundus images. Accurate fundus and/or retinal vessel maps give rise to longitudinal studies able to utilize multimodal image registration and disease/condition status measurements, as well as applications in surgery preparation and biometrics. This paper further investigates the use of a Convolutional Neural Network as a multi-channel classifier of retinal vessels using the Digital Retinal Images for Vessel Extraction database, a standardized set of fundus images used to gauge the effectiveness of classification algorithms. The CNN has a feed-forward architecture and varies from other published architectures in its combination of: max-pooling, zero-padding, ReLU layers, batch normalization, two dense layers and finally a Softmax activation function. Notably, the use of Adam to optimize training the CNN on retinal fundus images has not been found in prior review. This work builds on prior work of the authors, exploring the use of Gabor filters to boost the accuracy of the system to 0.9478 during post processing. The mean of a series of Gabor filters with varying frequencies and sigma values are applied to the output of the network and used to determine whether a pixel represents a vessel or non-vessel.

  11. Development of technology for creating intelligent control systems for power plants and propulsion systems for marine robotic systems

    NASA Astrophysics Data System (ADS)

    Iakovleva, E. V.; Momot, B. A.

    2017-10-01

    The object of this study is to develop a power plant and an electric propulsion control system for autonomous remotely controlled vessels. The tasks of the study are as follows: to assess remotely controlled vessels usage reasonability, to define the requirements for this type of vessel navigation. In addition, the paper presents the analysis of technical diagnostics systems. The developed electric propulsion control systems for vessels should provide improved reliability and efficiency of the propulsion complex to ensure the profitability of remotely controlled vessels.

  12. Aerodynamic and hydrodynamic model tests of the Enserch Garden Banks floating production facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, E.W.; Bauer, T.C.; Kelly, P.J.

    1995-12-01

    This paper presents the results of aerodynamic and hydrodynamic model tests of the Enserch Garden Banks, a semisubmersible Floating Production Facility (FPF) moored in 2,190-ft waters. During the wind tunnel tests, the steady component of wind and current forces/moments at various skew and heel axes were measured. The results were compared and calibrated against analytical calculations using techniques recommended by ABS and API. During the wave basin recommend test the mooring line tensions and vessel motions including the effects of dynamic wind and current were measured. An analytical calculation of the airgap, vessel motions, and mooring line loads were comparedmore » with wave basin model test results. This paper discusses the test objectives, test setups and agendas for wind and wave basin testing of a deepwater permanently moored floating production system. The experience from these tests and the comparison of measured tests results with analytical calculations will be of value to designers and operators contemplating the use of a semisubmersible based floating production system. The analysis procedures are aimed at estimating (1) vessel motions, (2) airgap, and (3) mooring line tensions with reasonable accuracy. Finally, this paper demonstrates how the model test results were interpolated and adapted in the design loop.« less

  13. WSF Biodiesel Demonstration Project Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Washington State University; University of Idaho; The Glosten Associates, Inc.

    2009-04-30

    In 2004, WSF canceled a biodiesel fuel test because of “product quality issues” that caused the fuel purifiers to clog. The cancelation of this test and the poor results negatively impacted the use of biodiesel in marine application in the Pacific Northwest. In 2006, The U.S. Department of Energy awarded the Puget Sound Clean Air Agency a grant to manage a scientific study investigating appropriate fuel specifications for biodiesel, fuel handling procedures and to conduct a fuel test using biodiesel fuels in WSF operations. The Agency put together a project team comprised of experts in fields of biodiesel research andmore » analysis, biodiesel production, marine engineering and WSF personnel. The team reviewed biodiesel technical papers, reviewed the 2004 fuel test results, designed a fuel test plan and provided technical assistance during the test. The research reviewed the available information on the 2004 fuel test and conducted mock laboratory experiments, but was not able to determine why the fuel filters clogged. The team then conducted a literature review and designed a fuel test plan. The team implemented a controlled introduction of biodiesel fuels to the test vessels while monitoring the environmental conditions on the vessels and checking fuel quality throughout the fuel distribution system. The fuel test was conducted on the same three vessels that participated in the canceled 2004 test using the same ferry routes. Each vessel used biodiesel produced from a different feedstock (i.e. soy, canola and yellow grease). The vessels all ran on ultra low sulfur diesel blended with biodiesel. The percentage of biodiesel was incrementally raised form from 5 to 20 percent. Once the vessels reached the 20 percent level, they continued at this blend ratio for the remainder of the test. Fuel samples were taken from the fuel manufacturer, during fueling operations and at several points onboard each vessel. WSF Engineers monitored the performance of the fuel systems and engines. Each test vessel did experience a microbial growth bloom that produced a build up of material in the fuel purifiers similar to material witnessed in the 2004 fuel test. A biocide was added with each fuel shipment and the problem subsided. In January of 2009, the WSF successfully completed an eleven month biodiesel fuel test using approximately 1,395,000 gallons of biodiesel blended fuels. The project demonstrated that biodiesel can be used successfully in marine vessels and that current ASTM specifications are satisfactory for marine vessels. Microbial growth in biodiesel diesel interface should be monitored. An inspection of the engines showed no signs of being negatively impacted by the test.« less

  14. A novel method for segmentation of Infrared Scanning Laser Ophthalmoscope (IR-SLO) images of retina.

    PubMed

    Ajaz, Aqsa; Aliahmad, Behzad; Kumar, Dinesh K

    2017-07-01

    Retinal vessel segmentation forms an essential element of automatic retinal disease screening systems. The development of multimodal imaging system with IR-SLO and OCT could help in studying the early stages of retinal disease. The advantages of IR-SLO to examine the alterations in the structure of retina and direct correlation with OCT can be useful for assessment of various diseases. This paper presents an automatic method for segmentation of IR-SLO fundus images based on the combination of morphological filters and image enhancement techniques. As a first step, the retinal vessels are contrasted using morphological filters followed by background exclusion using Contrast Limited Adaptive Histogram Equalization (CLAHE) and Bilateral filtering. The final segmentation is obtained by using Isodata technique. Our approach was tested on a set of 26 IR-SLO images and results were compared to two set of gold standard images. The performance of the proposed method was evaluated in terms of sensitivity, specificity and accuracy. The system has an average accuracy of 0.90 for both the sets.

  15. 77 FR 36488 - Proposed Information Collection; Comment Request; Vessel Monitoring System Requirements Under the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-19

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration Proposed Information Collection; Comment Request; Vessel Monitoring System Requirements Under the Western and Central Pacific...-fixing transmitters (``Vessel Monitoring System-VMS-units'') at all times except when the vessel is in...

  16. Podoplanin-Fc reduces lymphatic vessel formation in vitro and in vivo and causes disseminated intravascular coagulation when transgenically expressed in the skin

    PubMed Central

    Cueni, Leah N.; Chen, Lu; Zhang, Hui; Marino, Daniela; Huggenberger, Reto; Alitalo, Annamari; Bianchi, Roberta

    2010-01-01

    Podoplanin is a small transmembrane protein required for development and function of the lymphatic vascular system. To investigate the effects of interfering with its function, we produced an Fc fusion protein of its ectodomain. We found that podoplanin-Fc inhibited several functions of cultured lymphatic endothelial cells and also specifically suppressed lymphatic vessel growth, but not blood vessel growth, in mouse embryoid bodies in vitro and in mouse corneas in vivo. Using a keratin 14 expression cassette, we created transgenic mice that overexpressed podoplanin-Fc in the skin. No obvious outward phenotype was identified in these mice, but surprisingly, podoplanin-Fc—although produced specifically in the skin—entered the blood circulation and induced disseminated intravascular coagulation, characterized by microthrombi in most organs and by thrombocytopenia, occasionally leading to fatal hemorrhage. These findings reveal an important role of podoplanin in lymphatic vessel formation and indicate the potential of podoplanin-Fc as an inhibitor of lymphangiogenesis. These results also demonstrate the ability of podoplanin to induce platelet aggregation in vivo, which likely represents a major function of lymphatic endothelium. Finally, keratin 14 podoplanin-Fc mice represent a novel genetic animal model of disseminated intravascular coagulation. PMID:20716773

  17. 21 CFR 610.12 - Sterility.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... container material. (a) The test. Bulk material shall be tested separately from final container material and material from each final container shall be tested in individual test vessels as follows: (1) Using Fluid Thioglycollate Medium—(i) Bulk and final container material. The volume of product, as required by paragraph (d...

  18. 46 CFR 69.11 - Determining the measurement system or systems for a particular vessel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... only on the Great Lakes, unless the owner requests measurement under this system. (iii) A vessel that... substantially affects the vessel's gross tonnage. (iv) A vessel of war. (v) A non-self-propelled vessel not... only on the Great Lakes. [CGD 87-015b, 54 FR 37657, Sept. 12, 1989, as amended by CGD 92-058, 57 FR...

  19. 46 CFR 69.11 - Determining the measurement system or systems for a particular vessel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... only on the Great Lakes, unless the owner requests measurement under this system. (iii) A vessel that... substantially affects the vessel's gross tonnage. (iv) A vessel of war. (v) A non-self-propelled vessel not... only on the Great Lakes. [CGD 87-015b, 54 FR 37657, Sept. 12, 1989, as amended by CGD 92-058, 57 FR...

  20. 46 CFR 69.11 - Determining the measurement system or systems for a particular vessel.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... only on the Great Lakes, unless the owner requests measurement under this system. (iii) A vessel that... substantially affects the vessel's gross tonnage. (iv) A vessel of war. (v) A non-self-propelled vessel not... only on the Great Lakes. [CGD 87-015b, 54 FR 37657, Sept. 12, 1989, as amended by CGD 92-058, 57 FR...

  1. 46 CFR 69.11 - Determining the measurement system or systems for a particular vessel.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... only on the Great Lakes, unless the owner requests measurement under this system. (iii) A vessel that... substantially affects the vessel's gross tonnage. (iv) A vessel of war. (v) A non-self-propelled vessel not... only on the Great Lakes. [CGD 87-015b, 54 FR 37657, Sept. 12, 1989, as amended by CGD 92-058, 57 FR...

  2. 46 CFR 69.11 - Determining the measurement system or systems for a particular vessel.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... only on the Great Lakes, unless the owner requests measurement under this system. (iii) A vessel that... substantially affects the vessel's gross tonnage. (iv) A vessel of war. (v) A non-self-propelled vessel not... only on the Great Lakes. [CGD 87-015b, 54 FR 37657, Sept. 12, 1989, as amended by CGD 92-058, 57 FR...

  3. A New Technique to Map the Lymphatic Distribution and Alignment of the Penis.

    PubMed

    Long, Liu Yan; Qiang, Pan Fu; Ling, Tao; Wei, Zhang Yan; Long, Zhang Yu; Shan, Meng; Rong, Li Shi; Li, Li Hong

    2015-08-01

    The present study was to examine the distribution of lymphatic vessels in the penis of normal adult males, which could provide an anatomical basis for improvement of incisions in penile lengthening surgery, and may also help to prevent postoperative refractory edema. Thirteen normal adult male volunteers were recruited for this study. Contrast agent was injected subcutaneously in the foreskin of the penis, and after two minutes magnetic resonance lymphangiography (MRL) was performed. The acquired magnetic resonance images were analyzed to determine the changes in the number and diameter of lymphatic vessels in different parts of the penis. Maximum intensity projections (MIP) and materializes interactive medical image control system (MIMICS) were applied to analyze the overall distribution of lymphatic vessels in the penis. Magnetic resonance imaging (MRI) showed that the lymphatic vessels were in conspicuous contrast with surrounding tissues and could be clearly identified. Penile lymphatic vessels were clearly visible in the root of the penis. At the junction of the penis and the abdominal wall, all lymphatic vessels were found to be concentrated in the dorsal part of the penis. MIP two-dimensional reconstruction showed that the overall distribution of relatively large lymphatic vessels in the dorsal and ventral parts of the penis could be seen clearly on bilateral 45° position, but not inside the abdominal wall because some of lymphatic vessels were overlapped by other tissues in the abdomen. MIMICS three-dimensional reconstruction was able to reveal the overall spatial distribution of lymphatic vessels in the penis from any angle. The reconstruction results showed that there were 1-2 main lymphatic vessels on the root of dorsal penis, which coursed along the cavernous to the first physiological curvature of the penis. Lymphatic vessels merged on both sides of the ventral penis. At the root of the penis, lymphatic vessels gradually coursed to the dorsal surface of the penis and folded at the abdominal wall to the outside, and finally merged into the inguinal lymph nodes. The changes in distribution, number and diameter of the lymphatic vessels in the penis were observed by MRI. MIP and MIMICS reconstructions directly revealed the anatomical features of penile lymphatic vessels such as spatial distribution, overall alignment, and the relations to adjacent structures, drainage and reflux. The study will provide the anatomical basis for penile surgery, penile lymphatic reflux disorders caused by trauma or lymphatic vessels obstruction, and lymph node metastasis in penile cancer. © 2014 Wiley Periodicals, Inc.

  4. Design and Operation of A Setup with A Camera and Adjustable Mirror to Inspect the Sense-Wire Planes of the Time Projection Chamber Inside the MicroBooNE Cryostat

    DOE PAGES

    Carls, Benjamin; Horton-Smith, Glenn; James, Catherine C.; ...

    2015-08-26

    Detectors in particle physics, particularly when including cryogenic components, are often enclosed in vessels that do not provide any physical or visual access to the detectors themselves after installation. However, it can be desirable for experiments to visually investigate the inside of the vessel. The MicroBooNE cryostat hosts a TPC with sense-wire planes, which had to be inspected for damage such as breakage or sagging. This inspection was performed after the transportation of the vessel with the enclosed detector to its final location, but before filling with liquid argon. Our paper describes an approach to view the inside of themore » MicroBooNE cryostat with a setup of a camera and a mirror through one of its cryogenic service nozzles. The paper also describes the camera and mirror chosen for the operation, the illumination, and the mechanical structure of the setup. It explains how the system was operated and demonstrates its performance.« less

  5. 46 CFR 50.05-5 - Existing boilers, pressure vessels or piping systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Existing boilers, pressure vessels or piping systems. 50... ENGINEERING GENERAL PROVISIONS Application § 50.05-5 Existing boilers, pressure vessels or piping systems. (a) Whenever doubt exists as to the safety of an existing boiler, pressure vessel, or piping system, the marine...

  6. Electricity generation using electromagnetic radiation

    DOEpatents

    Halas, Nancy J.; Nordlander, Peter; Neumann, Oara

    2017-08-22

    In general, in one aspect, the invention relates to a system to create vapor for generating electric power. The system includes a vessel comprising a fluid and a complex and a turbine. The vessel of the system is configured to concentrate EM radiation received from an EM radiation source. The vessel of the system is further configured to apply the EM radiation to the complex, where the complex absorbs the EM radiation to generate heat. The vessel of the system is also configured to transform, using the heat generated by the complex, the fluid to vapor. The vessel of the system is further configured to sending the vapor to a turbine. The turbine of the system is configured to receive, from the vessel, the vapor used to generate the electric power.

  7. OceanRoute: Vessel Mobility Data Processing and Analyzing Model Based on MapReduce

    NASA Astrophysics Data System (ADS)

    Liu, Chao; Liu, Yingjian; Guo, Zhongwen; Jing, Wei

    2018-06-01

    The network coverage is a big problem in ocean communication, and there is no low-cost solution in the short term. Based on the knowledge of Mobile Delay Tolerant Network (MDTN), the mobility of vessels can create the chances of end-to-end communication. The mobility pattern of vessel is one of the key metrics on ocean MDTN network. Because of the high cost, few experiments have focused on research of vessel mobility pattern for the moment. In this paper, we study the traces of more than 4000 fishing and freight vessels. Firstly, to solve the data noise and sparsity problem, we design two algorithms to filter the noise and complement the missing data based on the vessel's turning feature. Secondly, after studying the traces of vessels, we observe that the vessel's traces are confined by invisible boundary. Thirdly, through defining the distance between traces, we design MR-Similarity algorithm to find the mobility pattern of vessels. Finally, we realize our algorithm on cluster and evaluate the performance and accuracy. Our results can provide the guidelines on design of data routing protocols on ocean MDTN.

  8. A novel retinal vessel extraction algorithm based on matched filtering and gradient vector flow

    NASA Astrophysics Data System (ADS)

    Yu, Lei; Xia, Mingliang; Xuan, Li

    2013-10-01

    The microvasculature network of retina plays an important role in the study and diagnosis of retinal diseases (age-related macular degeneration and diabetic retinopathy for example). Although it is possible to noninvasively acquire high-resolution retinal images with modern retinal imaging technologies, non-uniform illumination, the low contrast of thin vessels and the background noises all make it difficult for diagnosis. In this paper, we introduce a novel retinal vessel extraction algorithm based on gradient vector flow and matched filtering to segment retinal vessels with different likelihood. Firstly, we use isotropic Gaussian kernel and adaptive histogram equalization to smooth and enhance the retinal images respectively. Secondly, a multi-scale matched filtering method is adopted to extract the retinal vessels. Then, the gradient vector flow algorithm is introduced to locate the edge of the retinal vessels. Finally, we combine the results of matched filtering method and gradient vector flow algorithm to extract the vessels at different likelihood levels. The experiments demonstrate that our algorithm is efficient and the intensities of vessel images exactly represent the likelihood of the vessels.

  9. Scalable Emergency Response System for Oceangoing Assets. Final Summary Report

    DTIC Science & Technology

    2009-01-20

    Developed for platform defense of submarines and surface ships at sea and in port, the iRobot High Speed UUV enables rapid transit with respect to a ... high level decontamination, resulting in a return to port Decision Making Option C is to sealift via decontamination vessel contingent, and perform a ...the world aboard a prepared LCAC.48 A high - speed , over- 47 One Marine’s View. Retrieved from http://www.onemarinesview.com/one_marines_view/2006/09

  10. 54 FR 38044: National Emission Standards for Hazardous Air Pollutants; Benzene Emissions From Maleic Anhydride Plants, Ethylbenzene/Styrene Plants, Benzene Storage Vessels, Benzene Equipment Leaks, and Coke By- Product Recovery Plants

    EPA Pesticide Factsheets

    Final Rule on National Emission Standards for Hazardous Air Pollutants; Benzene Emissions From Maleic Anhydride Plants, Ethylbenzene/Styrene Plants, Benzene Storage Vessels, Benzene Equipment Leaks, and Coke By-Product Recovery Plants.

  11. 19 CFR 4.90 - Simultaneous vessel transactions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... mentioned in this section and the conditions stated in the sections indicated in the list: 121 For the purposes of this part, an inward foreign voyage is completed at the port of final discharge of inbound... ports (§ 4.88). (b) When a vessel is engaged simultaneously in two or more such transactions, the master...

  12. 33 CFR 157.03 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... port of final cargo discharge. Breadth or B means the maximum molded breadth of a vessel in meters... lightweight displacement and the total displacement of a vessel measured in water of specific gravity 1.025 at... of each is more than 1/15 of the total depth of the tank. Length or L means the distance in meters...

  13. 33 CFR 157.03 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... port of final cargo discharge. Breadth or B means the maximum molded breadth of a vessel in meters... lightweight displacement and the total displacement of a vessel measured in water of specific gravity 1.025 at... of each is more than 1/15 of the total depth of the tank. Length or L means the distance in meters...

  14. 33 CFR 157.03 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... port of final cargo discharge. Breadth or B means the maximum molded breadth of a vessel in meters... lightweight displacement and the total displacement of a vessel measured in water of specific gravity 1.025 at... of each is more than 1/15 of the total depth of the tank. Length or L means the distance in meters...

  15. 75 FR 73979 - Fisheries of the Northeastern United States; Discard Provision for Herring Midwater Trawl Vessels...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-30

    .... The publication of this action is part of a Court-approved joint motion to stay pending litigation...), National Oceanic and Atmospheric Administration (NOAA), Commerce. ACTION: Final rule. SUMMARY: Through this action, NMFS removes a regulatory exemption for midwater trawl herring vessels, which was originally...

  16. 33 CFR 96.380 - How will the Coast Guard handle compliance and enforcement of these regulations?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... safety management system while operating the vessel or transferring cargoes. (b) A foreign vessel that... GUARD, DEPARTMENT OF HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS How Will Safety Management Systems Be Certificated and Enforced...

  17. Final Report on ITER Task Agreement 81-08

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richard L. Moore

    As part of an ITER Implementing Task Agreement (ITA) between the ITER US Participant Team (PT) and the ITER International Team (IT), the INL Fusion Safety Program was tasked to provide the ITER IT with upgrades to the fusion version of the MELCOR 1.8.5 code including a beryllium dust oxidation model. The purpose of this model is to allow the ITER IT to investigate hydrogen production from beryllium dust layers on hot surfaces inside the ITER vacuum vessel (VV) during in-vessel loss-of-cooling accidents (LOCAs). Also included in the ITER ITA was a task to construct a RELAP5/ATHENA model of themore » ITER divertor cooling loop to model the draining of the loop during a large ex-vessel pipe break followed by an in-vessel divertor break and compare the results to a simular MELCOR model developed by the ITER IT. This report, which is the final report for this agreement, documents the completion of the work scope under this ITER TA, designated as TA 81-08.« less

  18. Fukushima Daiichi Unit 1 Ex-Vessel Prediction: Core-Concrete Interaction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robb, Kevin R.; Farmer, Mitchell T.; Francis, Matthew W.

    Lower head failure and corium-concrete interaction were predicted to occur at Fukushima Daiichi Unit 1 (1F1) by several different system-level code analyses, including MELCOR v2.1 and MAAP5. Although these codes capture a wide range of accident phenomena, they do not contain detailed models for ex-vessel core melt behavior. However, specialized codes exist for the analysis of ex-vessel melt spreading (e.g., MELTSPREAD) and long-term debris coolability (e.g., CORQUENCH). On this basis, in this paper an analysis was carried out to further evaluate ex-vessel behavior for 1F1 using MELTSPREAD and CORQUENCH. Best-estimate melt pour conditions predicted by MELCOR v2.1 and MAAP5 weremore » used as input. MELTSPREAD was then used to predict the spatially dependent melt conditions and extent of spreading during relocation from the vessel. The results of the MELTSPREAD analysis are reported in a companion paper. This information was used as input for the long-term debris coolability analysis with CORQUENCH. For the MELCOR-based melt pour scenario, CORQUENCH predicted the melt would readily cool within 2.5 h after the pour, and the sumps would experience limited ablation (approximately 18 cm) under water-flooded conditions. Finally, for the MAAP-based melt pour scenarios, CORQUENCH predicted that the melt would cool in approximately 22.5 h, and the sumps would experience approximately 65 cm of concrete ablation under water-flooded conditions.« less

  19. Fukushima Daiichi Unit 1 Ex-Vessel Prediction: Core-Concrete Interaction

    DOE PAGES

    Robb, Kevin R.; Farmer, Mitchell T.; Francis, Matthew W.

    2016-10-31

    Lower head failure and corium-concrete interaction were predicted to occur at Fukushima Daiichi Unit 1 (1F1) by several different system-level code analyses, including MELCOR v2.1 and MAAP5. Although these codes capture a wide range of accident phenomena, they do not contain detailed models for ex-vessel core melt behavior. However, specialized codes exist for the analysis of ex-vessel melt spreading (e.g., MELTSPREAD) and long-term debris coolability (e.g., CORQUENCH). On this basis, in this paper an analysis was carried out to further evaluate ex-vessel behavior for 1F1 using MELTSPREAD and CORQUENCH. Best-estimate melt pour conditions predicted by MELCOR v2.1 and MAAP5 weremore » used as input. MELTSPREAD was then used to predict the spatially dependent melt conditions and extent of spreading during relocation from the vessel. The results of the MELTSPREAD analysis are reported in a companion paper. This information was used as input for the long-term debris coolability analysis with CORQUENCH. For the MELCOR-based melt pour scenario, CORQUENCH predicted the melt would readily cool within 2.5 h after the pour, and the sumps would experience limited ablation (approximately 18 cm) under water-flooded conditions. Finally, for the MAAP-based melt pour scenarios, CORQUENCH predicted that the melt would cool in approximately 22.5 h, and the sumps would experience approximately 65 cm of concrete ablation under water-flooded conditions.« less

  20. System Design and Development of a Robotic Device for Automated Venipuncture and Diagnostic Blood Cell Analysis.

    PubMed

    Balter, Max L; Chen, Alvin I; Fromholtz, Alex; Gorshkov, Alex; Maguire, Tim J; Yarmush, Martin L

    2016-10-01

    Diagnostic blood testing is the most prevalent medical procedure performed in the world and forms the cornerstone of modern health care delivery. Yet blood tests are still predominantly carried out in centralized labs using large-volume samples acquired by manual venipuncture, and no end-to-end solution from blood draw to sample analysis exists today. Our group is developing a platform device that merges robotic phlebotomy with automated diagnostics to rapidly deliver patient information at the site of the blood draw. The system couples an image-guided venipuncture robot, designed to address the challenges of routine venous access, with a centrifuge-based blood analyzer to obtain quantitative measurements of hematology. In this paper, we first present the system design and architecture of the integrated device. We then perform a series of in vitro experiments to evaluate the cannulation accuracy of the system on blood vessel phantoms. Next, we assess the effects of vessel diameter, needle gauge, flow rate, and viscosity on the rate of sample collection. Finally, we demonstrate proof-of-concept of a white cell assay on the blood analyzer using in vitro human samples spiked with fluorescently labeled microbeads.

  1. [Oxidative stress and vascular function].

    PubMed

    Urbański, Karol; Nowak, Michal; Guzik, Tomasz J

    2013-01-01

    The maintenance of blood vessel homeostasis is closely associated with Reactive Oxygen and Nitrogen Species (ROS and RNS) production in the blood vessel wall. The main molecules taking part in this process are nitric oxide (NO), superoxide anion (O2*-), hydrogen peroxide (H2O2) and their derivatives. The production of these factors occurs in health and disease, however the increased ROS release is often referred to as oxidative stress. While initially oxidative stress was considered systemically, recent data indicate that it occurs locally in subcellular spaces and may be a result of dysfunction of individual enzyme systems. Oxidative stress induces inflammation, proliferation and migration of vascular smooth muscle cells, may regulate apoptosis and the function of the cells of vascular wall, finally leading to dysfunction of endothelium, media and adventitia, leading to cardiovascular diseases such as atherosclerosis, hypertension or heart failure. It is believed that a family of NADPH oxidases is the main source of ROS in the vessel wall, but also in other organs and tissues. It consists of seven known and quite precisely characterized homologues (NOX1, NOX2, NOX3, NOX4, NOX5, DUOX1 and DUOX2) which often have very distinct activity and cellular localization and function. Besides harmful actions, we are beginning to understand the protective effects of ROS and RNS. They have many functions regulating redox-sensitive gene expression and influencing a proper function of cells and vessels. NOX4 has been particularly well characterized in this respect. Thus, the maintenance of the right homeostasis depends not only on ROS removing capabilities, but especially on preserving the adequate level of ROS production.

  2. Tailoring vessel morphology in vivo

    NASA Astrophysics Data System (ADS)

    Gould, Daniel Joseph

    Tissue engineering is a rapidly growing field which seeks to provide alternatives to organ transplantation in order to address the increasing need for transplantable tissues. One huge hurdle in this effort is the provision of thick tissues; this hurdle exists because currently there is no way to provide prevascularized or rapidly vascularizable scaffolds. To design thick, vascularized tissues, scaffolds are needed that can induce vessels which are similar to the microvasculature found in normal tissues. Angiogenic biomaterials are being developed to provide useful scaffolds to address this problem. In this thesis angiogenic and cell signaling and adhesion factors were incorporated into a biomimetic poly(ethylene glycol) (PEG) hydrogel system. The composition of these hydrogels was precisely tuned to induce the formation of differing vessel morphology. To sensitively measure induced microvascular morphology and to compare it to native microvessels in several tissues, this thesis developed an image-based tool for quantification of scale invariant and classical measures of vessel morphology. The tool displayed great utility in the comparison of native vessels and remodeling vessels in normal tissues. To utilize this tool to tune the vessel response in vivo, Flk1::myr-mCherry fluorescently labeled mice were implanted with Platelet Derived Growth Factor-BB (PDGF-BB) and basic Fibroblast Growth Factor (FGF-2) containing PEG-based hydrogels in a modified mouse corneal angiogenesis assay. Resulting vessels were imaged with confocal microscopy, analyzed with the image based tool created in this thesis to compare morphological differences between treatment groups, and used to create a linear relationship between space filling parameters and dose of growth factor release. Morphological parameters of native mouse tissue vessels were then compared to the linear fit to calculate the dose of growth factors needed to induce vessels similar in morphology to native vessels. Resulting induced vessels did match in morphology to the target vessels. Several other covalently bound signals were then analyzed in the assay and resulting morphology of vessels was compared in several studies which further highlighted the utility of the micropocket assay in conjunction with the image based tool for vessel morphological quantification. Finally, an alternative method to provide rapid vasculature to the constructs, which relied on pre-seeded hydrogels encapsulated endothelial cells was also developed and shown to allow anastamosis between induced host vessels and the implanted construct within 48 hours. These results indicate great promise in the rational design of synthetic, bioactive hydrogels, which can be used as a platform to study microvascular induction for regenerative medicine and angiogenesis research. Future applications of this research may help to develop therapeutic strategies to ameliorate human disease by replacing organs or correcting vessel morphology in the case of ischemic diseases and cancer.

  3. Radiant vessel auxiliary cooling system

    DOEpatents

    Germer, John H.

    1987-01-01

    In a modular liquid-metal pool breeder reactor, a radiant vessel auxiliary cooling system is disclosed for removing the residual heat resulting from the shutdown of a reactor by a completely passive heat transfer system. A shell surrounds the reactor and containment vessel, separated from the containment vessel by an air passage. Natural circulation of air is provided by air vents at the lower and upper ends of the shell. Longitudinal, radial and inwardly extending fins extend from the shell into the air passage. The fins are heated by radiation from the containment vessel and convect the heat to the circulating air. Residual heat from the primary reactor vessel is transmitted from the reactor vessel through an inert gas plenum to a guard or containment vessel designed to contain any leaking coolant. The containment vessel is conventional and is surrounded by the shell.

  4. Benefits of Synchrotron Microangiography for Dynamic Studies of Smooth Muscle and Endothelial Roles in the Pathophysiology of Vascular Disease

    NASA Astrophysics Data System (ADS)

    Pearson, James T.; Schwenke, Daryl O.; Jenkins, Mathew J.; Edgley, Amanda J.; Sonobe, Takashi; Ishibashi-Ueda, Hatsue; Umetani, Keiji; Eppel, Gabriela A.; Evans, Roger G.; Okura, Yasuhiko; Shirai, Mikiyasu

    2010-07-01

    Changes in endothelial and smooth muscle function compromise organ perfusion in the chronic disease states of diabetes, atherosclerosis and hypertension. Moreover, vascular dysfunction increases the likelihood of lethal acute events such as myocardial infarction and stroke, which are now leading causes of adult mortality. Many circulating and local tissue factors in these disease states contribute to impaired vasomotor regulation of the arterial vessels, leading to spasm, chronic constriction and eventually vessel remodelling. X-ray contrast absorption imaging allows assessment of vessel lumen diameter and the factors contributing to steady-state vessel calibre, however, conventional clinical devices (>200 μm resolution) are not adequate to detect microvessels or accurately assess function in real time. Using synchrotron imaging we are now able to detect small vessel calibres (˜30 μm) and quantify regional differences in calibre even under conditions of high heart rate (>500 bpm). Herein we describe recent experiments that were conducted at the Japanese Synchrotron, SPring-8 using anaesthetised Sprague-Dawley rats and C57Bl/6 mice and a synchrotron radiation contrast angiography (single narrow energy bandwidth) approach based on selective arterial injection of iodine contrast agents. Application of this approach to imaging of the heart and other vasculatures are described. Our studies show that within-animal comparisons of 3-4 branching orders of arterial vessels are possible using small bolus contrast injections and appropriate contrast washout times (15-30 min) in many organ systems. Determination of relative calibre changes before and after any treatment allows us to evaluate the contributions of different endogenous factors and ligand-receptor pathways in the maintenance of vasomotor tone. Finally, we will present our findings relating to novel therapies to prevent endothelial dysfunction in heart failure.

  5. Benefits of Synchrotron Microangiography for Dynamic Studies of Smooth Muscle and Endothelial Roles in the Pathophysiology of Vascular Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pearson, James T.; Department of Physiology, Monash University, 3800 Clayton; Schwenke, Daryl O.

    2010-07-23

    Changes in endothelial and smooth muscle function compromise organ perfusion in the chronic disease states of diabetes, atherosclerosis and hypertension. Moreover, vascular dysfunction increases the likelihood of lethal acute events such as myocardial infarction and stroke, which are now leading causes of adult mortality. Many circulating and local tissue factors in these disease states contribute to impaired vasomotor regulation of the arterial vessels, leading to spasm, chronic constriction and eventually vessel remodelling. X-ray contrast absorption imaging allows assessment of vessel lumen diameter and the factors contributing to steady-state vessel calibre, however, conventional clinical devices (>200 {mu}m resolution) are not adequatemore » to detect microvessels or accurately assess function in real time. Using synchrotron imaging we are now able to detect small vessel calibres ({approx}30 {mu}m) and quantify regional differences in calibre even under conditions of high heart rate (>500 bpm). Herein we describe recent experiments that were conducted at the Japanese Synchrotron, SPring-8 using anaesthetised Sprague-Dawley rats and C57Bl/6 mice and a synchrotron radiation contrast angiography (single narrow energy bandwidth) approach based on selective arterial injection of iodine contrast agents. Application of this approach to imaging of the heart and other vasculatures are described. Our studies show that within-animal comparisons of 3-4 branching orders of arterial vessels are possible using small bolus contrast injections and appropriate contrast washout times (15-30 min) in many organ systems. Determination of relative calibre changes before and after any treatment allows us to evaluate the contributions of different endogenous factors and ligand-receptor pathways in the maintenance of vasomotor tone. Finally, we will present our findings relating to novel therapies to prevent endothelial dysfunction in heart failure.« less

  6. 76 FR 11680 - Service Contracts and Non-Vessel-Operating Service Arrangements; Transmission of Approved Log-In...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-03

    ... Contracts and Non-Vessel-Operating Service Arrangements; Transmission of Approved Log-In ID and Passwords... advise applicants for log-in IDs and passwords. DATES: The Final Rule is effective March 3, 2011. FOR... the U.S. Mail to transmit approved log-on IDs and password to registrants in the Commission's...

  7. 76 FR 47996 - Security Zone; 2011 Seattle Seafair Fleet Week Moving Vessels, Puget Sound, WA; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-08

    ... Zone; 2011 Seattle Seafair Fleet Week Moving Vessels, Puget Sound, WA; Correction AGENCY: Coast Guard...-mail ENS Anthony P. LaBoy, Coast Guard Sector Puget Sound, Waterways Management Division; telephone 206-217- 6323, e-mail SectorPugetSound[email protected] . Correction In the temporary final rule FR Doc. 2011...

  8. Retinal vessel segmentation on SLO image

    PubMed Central

    Xu, Juan; Ishikawa, Hiroshi; Wollstein, Gadi; Schuman, Joel S.

    2010-01-01

    A scanning laser ophthalmoscopy (SLO) image, taken from optical coherence tomography (OCT), usually has lower global/local contrast and more noise compared to the traditional retinal photograph, which makes the vessel segmentation challenging work. A hybrid algorithm is proposed to efficiently solve these problems by fusing several designed methods, taking the advantages of each method and reducing the error measurements. The algorithm has several steps consisting of image preprocessing, thresholding probe and weighted fusing. Four different methods are first designed to transform the SLO image into feature response images by taking different combinations of matched filter, contrast enhancement and mathematical morphology operators. A thresholding probe algorithm is then applied on those response images to obtain four vessel maps. Weighted majority opinion is used to fuse these vessel maps and generate a final vessel map. The experimental results showed that the proposed hybrid algorithm could successfully segment the blood vessels on SLO images, by detecting the major and small vessels and suppressing the noises. The algorithm showed substantial potential in various clinical applications. The use of this method can be also extended to medical image registration based on blood vessel location. PMID:19163149

  9. The role of transvaginal power Doppler ultrasound in the differential diagnosis of benign intrauterine focal lesions.

    PubMed

    Cogendez, Ebru; Eken, Meryem Kurek; Bakal, Nuray; Gun, Ismet; Kaygusuz, Ecmel Isik; Karateke, Ates

    2015-10-01

    The purpose of this prospective study was to assess the role of power Doppler imaging in the differential diagnosis of benign intrauterine focal lesions such as endometrial polyps and submucous myomas using the characteristics of power Doppler flow mapping. A total of 480 premenopausal patients with abnormal uterine bleeding were evaluated by transvaginal ultrasonography (TVS) searching for intrauterine pathology. Sixty-four patients with a suspicious focal endometrial lesion received saline infusion sonography (SIS) after TVS. Fifty-eight patients with focal endometrial lesions underwent power Doppler ultrasound (PDUS). Three different vascular flow patterns were defined: Single vessel pattern, multiple vessel pattern, and circular flow pattern. Finally, hysteroscopic resection was performed in all cases, and Doppler flow characteristics were then compared with the final histopathological findings. Histopathological results were as follows: endometrial polyp: 40 (69 %), submucous myoma: 18 (31 %). Of the cases with endometrial polyps, 80 % demonstrated a single vessel pattern, 7.5 % a multiple vessel pattern, and 0 % a circular pattern. Vascularization was not observed in 12.5 % of patients with polyps. Of the cases with submucousal myomas, 72.2 % demonstrated a circular flow pattern, 27.8 % a multiple vessel pattern, and none of them showed a single vessel pattern. The sensitivity, specificity, and positive and negative predictive values of the single vessel pattern in diagnosing endometrial polyps were 80, 100, 100, and 69.2 %, respectively; and for the circular pattern in diagnosing submucous myoma, these were 72.2, 100, 100, and 88.9 %, respectively. Power Doppler blood flow mapping is a useful, practical, and noninvasive diagnostic method for the differential diagnosis of benign intrauterine focal lesions. Especially in cases of recurrent abnormal uterine bleeding, recurrent abortion, and infertility, PDUS can be preferred as a first-line diagnostic method.

  10. Development of a Procedure for the Selection of Candidate Vessels of Opportunity in Support of the Submarine Rescue Diving and Recompression System

    DTIC Science & Technology

    2005-06-01

    ACRONYMS AHT Anchor Handling Tug AP After Perpendicular ASRV Australian Submarine Rescue Vehicle ASSET Advanced Surface Ship Evaluation Tool AUWS...Five hours after the Squalus sank, its sister ship, USS Sculpin began searching at the Squalus’ reported position prior to diving. Due to an error...ashore in recording that position, Sculpin was searching five miles from Squalus’ actual position. Finally, Ensign Ned Denby on 21 the bridge of Sculpin

  11. 33 CFR 157.140 - Tank vessel inspections.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Crude Oil Washing (COW) System on Tank Vessels Inspections § 157.140 Tank vessel inspections. (a) Before... having a COW system under § 157.10(e), § 157.10(a)(2), or § 157.10c(b)(2) and each foreign tank vessel...

  12. 33 CFR 96.220 - What makes up a safety management system?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.220 What makes up a safety management system? (a) The safety management system must document the responsible person's— (1) Safety and pollution prevention...

  13. Automatic non-proliferative diabetic retinopathy screening system based on color fundus image.

    PubMed

    Xiao, Zhitao; Zhang, Xinpeng; Geng, Lei; Zhang, Fang; Wu, Jun; Tong, Jun; Ogunbona, Philip O; Shan, Chunyan

    2017-10-26

    Non-proliferative diabetic retinopathy is the early stage of diabetic retinopathy. Automatic detection of non-proliferative diabetic retinopathy is significant for clinical diagnosis, early screening and course progression of patients. This paper introduces the design and implementation of an automatic system for screening non-proliferative diabetic retinopathy based on color fundus images. Firstly, the fundus structures, including blood vessels, optic disc and macula, are extracted and located, respectively. In particular, a new optic disc localization method using parabolic fitting is proposed based on the physiological structure characteristics of optic disc and blood vessels. Then, early lesions, such as microaneurysms, hemorrhages and hard exudates, are detected based on their respective characteristics. An equivalent optical model simulating human eyes is designed based on the anatomical structure of retina. Main structures and early lesions are reconstructed in the 3D space for better visualization. Finally, the severity of each image is evaluated based on the international criteria of diabetic retinopathy. The system has been tested on public databases and images from hospitals. Experimental results demonstrate that the proposed system achieves high accuracy for main structures and early lesions detection. The results of severity classification for non-proliferative diabetic retinopathy are also accurate and suitable. Our system can assist ophthalmologists for clinical diagnosis, automatic screening and course progression of patients.

  14. 33 CFR 157.102 - Plans for foreign tank vessels: Submission.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels General § 157.102 Plans for foreign tank vessels: Submission. If the owner or operator of a foreign tank vessel having a COW system under... include— (a) A drawing or diagram of the COW pumping and piping system that meets 46 CFR 56.01-10(d); (b...

  15. Development and origins of zebrafish ocular vasculature.

    PubMed

    Kaufman, Rivka; Weiss, Omri; Sebbagh, Meyrav; Ravid, Revital; Gibbs-Bar, Liron; Yaniv, Karina; Inbal, Adi

    2015-03-27

    The developing eye receives blood supply from two vascular systems, the intraocular hyaloid system and the superficial choroidal vessels. In zebrafish, a highly stereotypic and simple set of vessels develops on the surface of the eye prior to development of choroidal vessels. The origins and formation of this so-called superficial system have not been described. We have analyzed the development of superficial vessels by time-lapse imaging and identified their origins by photoconversion experiments in kdrl:Kaede transgenic embryos. We show that the entire superficial system is derived from a venous origin, and surprisingly, we find that the hyaloid system has, in addition to its previously described arterial origin, a venous origin for specific vessels. Despite arising solely from a vein, one of the vessels in the superficial system, the nasal radial vessel (NRV), appears to acquire an arterial identity while growing over the nasal aspect of the eye and this happens in a blood flow-independent manner. Our results provide a thorough analysis of the early development and origins of zebrafish ocular vessels and establish the superficial vasculature as a model for studying vascular patterning in the context of the developing eye.

  16. ICARUS: An Innovative Large LAR Detector for Neutrino Physics

    NASA Astrophysics Data System (ADS)

    Vignoli, C.; Barni, D.; Disdier, J. M.; Rampoldi, D.; Icarus Collaboration

    2006-04-01

    ICARUS is an international project that foresees the installation of very large LAr detectors inside the Gran Sasso underground laboratory in order to be sensitive to rare phenomena of particle physics. The detection technique is based on the collection of electrons produced by particle interactions in LAr by a matrix of thousands of thin wires. At the moment the project foresees the installation of a 600,000-kg vessel (T600). The total amount of LAr can be expanded in a modular way to masses of the order of 106 kg. The T600 houses two identical 300,000-kg Ar sub-cryostats that are aluminum boxes about 20-m long, 4-m high and 4-m wide. Safety requirements for the underground installation have led to a unique design for the vessels to prevent LAr spillages even in the case of inner cryostat failure. Electrons must drift over meters requiring the development of special gas and liquid Ar purification units to provide an extremely high LAr purity (better then 0.1 ppb). The cooling system has been designed to assure a high thermal uniformity in the detector volume (less than 1-K differential). The cryogenic system associated with the final ICARUS configuration is based on three N2 refrigerators, three 30-m3 tanks and pump driven two-phase N2 forced-flow cooling of the various sub-systems. The T600 was successfully tested in Pavia in 2001 and it is now under installation in Gran Sasso for final operation. The future mass expansion strategy is under investigation.

  17. 33 CFR 96.300 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS How Will Safety Management Systems... international certification for the company's and vessel's safety management system. ...

  18. Optics based signal processing methods for intraoperative blood vessel detection and quantification in real time (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Chaturvedi, Amal; Shukair, Shetha A.; Le Rolland, Paul; Vijayvergia, Mayank; Subramanian, Hariharan; Gunn, Jonathan W.

    2016-03-01

    Minimally invasive operations require surgeons to make difficult cuts to blood vessels and other tissues with impaired tactile and visual feedback. This leads to inadvertent cuts to blood vessels hidden beneath tissue, causing serious health risks to patients and a non-reimbursable financial burden to hospitals. Intraoperative imaging technologies have been developed, but these expensive systems can be cumbersome and provide only a high-level view of blood vessel networks. In this research, we propose a lean reflectance-based system, comprised of a dual wavelength LED, photodiode, and novel signal processing algorithms for rapid vessel characterization. Since this system takes advantage of the inherent pulsatile light absorption characteristics of blood vessels, no contrast agent is required for its ability to detect the presence of a blood vessel buried deep inside any tissue type (up to a cm) in real time. Once a vessel is detected, the system is able to estimate the distance of the vessel from the probe and the diameter size of the vessel (with a resolution of ~2mm), as well as delineate the type of tissue surrounding the vessel. The system is low-cost, functions in real-time, and could be mounted on already existing surgical tools, such as Kittner dissectors or laparoscopic suction irrigation cannulae. Having been successfully validated ex vivo, this technology will next be tested in a live porcine study and eventually in clinical trials.

  19. Design of Degaussing System and Demonstration of Signature Reduction on Ship Model through Laboratory Experiments

    NASA Astrophysics Data System (ADS)

    Varma, R. A. Raveendra

    Magnetic fields of naval vessels are widely used all over the world for detection and localization of naval vessel. Magnetic Anomaly Detectors (MADs) installed on air borne vehicles are used to detect submarine operating in shallow waters. Underwater mines fitted with magnetic sensor are used for detection and destruction of naval vessels in the times of conflict. Reduction of magnetic signature of naval vessels is carried out by deperming and installation of degaussing system onboard the vessel. Present paper elaborates details of studies carried out at Magnetics Division of Naval Science and Technological Laboratory (NSTL) for minimizing the magnetic signature of naval vessels by designing a degaussing system. Magnetic fields of a small ship model are predicted and a degaussing system is designed for reducing magnetic detection. The details of the model, methodology used for estimation of magnetic signature of the vessel and design of degaussing system is brought out in this paper with details of experimental setup and results.

  20. Automated anatomical labeling method for abdominal arteries extracted from 3D abdominal CT images

    NASA Astrophysics Data System (ADS)

    Oda, Masahiro; Hoang, Bui Huy; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Mori, Kensaku

    2012-02-01

    This paper presents an automated anatomical labeling method of abdominal arteries. In abdominal surgery, understanding of blood vessel structure concerning with a target organ is very important. Branching pattern of blood vessels differs among individuals. It is required to develop a system that can assist understanding of a blood vessel structure and anatomical names of blood vessels of a patient. Previous anatomical labbeling methods for abdominal arteries deal with either of the upper or lower abdominal arteries. In this paper, we present an automated anatomical labeling method of both of the upper and lower abdominal arteries extracted from CT images. We obtain a tree structure of artery regions and calculate feature values for each branch. These feature values include the diameter, curvature, direction, and running vectors of a branch. Target arteries of this method are grouped based on branching conditions. The following processes are separately applied for each group. We compute candidate artery names by using classifiers that are trained to output artery names. A correction process of the candidate anatomical names based on the rule of majority is applied to determine final names. We applied the proposed method to 23 cases of 3D abdominal CT images. Experimental results showed that the proposed method is able to perform nomenclature of entire major abdominal arteries. The recall and the precision rates of labeling are 79.01% and 80.41%, respectively.

  1. 46 CFR 128.130 - Vital systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... auxiliaries vital to the vessel's survivability and safety. (10) Any other marine-engineering system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT... vessel's survivability and safety. For the purpose of this subchapter, the following are vital systems...

  2. 46 CFR 128.130 - Vital systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... auxiliaries vital to the vessel's survivability and safety. (10) Any other marine-engineering system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT... vessel's survivability and safety. For the purpose of this subchapter, the following are vital systems...

  3. 46 CFR 128.130 - Vital systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... auxiliaries vital to the vessel's survivability and safety. (10) Any other marine-engineering system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT... vessel's survivability and safety. For the purpose of this subchapter, the following are vital systems...

  4. 46 CFR 128.130 - Vital systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... auxiliaries vital to the vessel's survivability and safety. (10) Any other marine-engineering system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT... vessel's survivability and safety. For the purpose of this subchapter, the following are vital systems...

  5. 77 FR 6013 - Moving Security Zone Around Escorted Vessels On the Lower Mississippi River Between Mile Marker...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-07

    ...: Temporary final rule. SUMMARY: The Captain of the Port of New Orleans (COTP New Orleans) has established... need of escort protection by the COTP New Orleans for security reasons. No person or vessel is... COTP New Orleans. DATES: This rule is effective from January 1, 2012, through March 31, 2012. ADDRESSES...

  6. Browns Ferry Unit-3 cavity neutron spectral analysis. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, G.C.

    1981-08-01

    This report describes neutron dosimetry measurements performed in the Browns Ferry Unit-3 reactor cavity using multiple dosimeter and spectrum unfolding techniques to assess radiation-induced degradation of nuclear plant pressure vessels. Test results and conclusions indicating the feasibility of determining neutron flux spectra and the densities in the pressure vessel cavity region via dosimetric measurements are presented.

  7. Symbol interval optimization for molecular communication with drift.

    PubMed

    Kim, Na-Rae; Eckford, Andrew W; Chae, Chan-Byoung

    2014-09-01

    In this paper, we propose a symbol interval optimization algorithm in molecular communication with drift. Proper symbol intervals are important in practical communication systems since information needs to be sent as fast as possible with low error rates. There is a trade-off, however, between symbol intervals and inter-symbol interference (ISI) from Brownian motion. Thus, we find proper symbol interval values considering the ISI inside two kinds of blood vessels, and also suggest no ISI system for strong drift models. Finally, an isomer-based molecule shift keying (IMoSK) is applied to calculate achievable data transmission rates (achievable rates, hereafter). Normalized achievable rates are also obtained and compared in one-symbol ISI and no ISI systems.

  8. 33 CFR 187.304 - What vessels must be titled?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false What vessels must be titled? 187.304 Section 187.304 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) BOATING SAFETY VESSEL IDENTIFICATION SYSTEM Guidelines for State Vessel Titling Systems § 187.304...

  9. 33 CFR 187.304 - What vessels must be titled?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What vessels must be titled? 187.304 Section 187.304 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) BOATING SAFETY VESSEL IDENTIFICATION SYSTEM Guidelines for State Vessel Titling Systems § 187.304...

  10. 50 CFR 665.19 - Vessel monitoring system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 13 2012-10-01 2012-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...

  11. 50 CFR 665.19 - Vessel monitoring system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 13 2013-10-01 2013-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...

  12. 50 CFR 665.19 - Vessel monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 11 2011-10-01 2011-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...

  13. 33 CFR 96.240 - What functional requirements must a safety management system meet?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... a safety management system meet? 96.240 Section 96.240 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.240 What functional...

  14. 33 CFR 96.230 - What objectives must a safety management system meet?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... management system meet? 96.230 Section 96.230 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.230 What objectives must a safety...

  15. 50 CFR 665.19 - Vessel monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...

  16. 75 FR 62098 - Proposed Information Collection; Comment Request; Expanded Vessel Monitoring System Requirement...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-07

    ... Collection; Comment Request; Expanded Vessel Monitoring System Requirement in the Pacific Coast Groundfish... and use a vessel monitoring system (VMS) that automatically sends hourly position reports. Exemptions... declaration reporting system are not expected to change the public reporting burden. II. Method of Collection...

  17. 78 FR 58286 - Proposed Information Collection; Comment Request; Western Region Vessel Monitoring System and Pre...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-23

    ... Collection; Comment Request; Western Region Vessel Monitoring System and Pre-Trip Reporting Requirements... information or new problems in the fisheries. Vessel Monitoring System (VMS) units will facilitate enforcement... monitoring system (VMS) activation reports, 15 minutes; pre-trip reports, 5 minutes. Estimated Burden Hours...

  18. High throughput chemical munitions treatment system

    DOEpatents

    Haroldsen, Brent L [Manteca, CA; Stofleth, Jerome H [Albuquerque, NM; Didlake, Jr., John E.; Wu, Benjamin C-P [San Ramon, CA

    2011-11-01

    A new High-Throughput Explosive Destruction System is disclosed. The new system is comprised of two side-by-side detonation containment vessels each comprising first and second halves that feed into a single agent treatment vessel. Both detonation containment vessels further comprise a surrounding ventilation facility. Moreover, the detonation containment vessels are designed to separate into two half-shells, wherein one shell can be moved axially away from the fixed, second half for ease of access and loading. The vessels are closed by means of a surrounding, clam-shell type locking seal mechanisms.

  19. 46 CFR 184.100 - General requirement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT General Provisions § 184.100 General requirement. (a) Vessel control systems and other miscellaneous systems and equipment required by this part must...

  20. Demonstration of vessels in CNS and other organs by AMG silver enhancement of colloidal gold particles dispersed in gelatine.

    PubMed

    Danscher, G; Andreasen, A

    1997-12-01

    We present a new autometallographic technique for demonstrating vessels and other small cavities at light microscopy (LM) and electron microscopy (EM) levels. It is possible to obtain detailed knowledge of the 3-D appearance of the vascular system by exchanging blood with a 40 degrees C, 8% gelatine solution containing colloidal gold particles (gold gelatine solution, GGS) and ensuing silver enhancement of the gold particles by autometallography (AMG). The GGS-AMG technique demonstrates the vascular system as a dark web that can be studied in cryostat, vibratome, methacrylate, paraffin and Epon sections at all magnifications. The infused GGS becomes increasingly viscous and finally becomes rigid when the temperature falls below 20 degrees C. An additional advantage of this technique is the fact that none of the tested counterstains or immunotechniques interfere with this AMG approach. The GGS-AMG technique is demonstrated on rat brains but can be applied to any organ. We believe that the present technique is valuable for both experimental studies and routine pathology.

  1. Palm Vein Verification Using Multiple Features and Locality Preserving Projections

    PubMed Central

    Bu, Wei; Wu, Xiangqian; Zhao, Qiushi

    2014-01-01

    Biometrics is defined as identifying people by their physiological characteristic, such as iris pattern, fingerprint, and face, or by some aspects of their behavior, such as voice, signature, and gesture. Considerable attention has been drawn on these issues during the last several decades. And many biometric systems for commercial applications have been successfully developed. Recently, the vein pattern biometric becomes increasingly attractive for its uniqueness, stability, and noninvasiveness. A vein pattern is the physical distribution structure of the blood vessels underneath a person's skin. The palm vein pattern is very ganglion and it shows a huge number of vessels. The attitude of the palm vein vessels stays in the same location for the whole life and its pattern is definitely unique. In our work, the matching filter method is proposed for the palm vein image enhancement. New palm vein features extraction methods, global feature extracted based on wavelet coefficients and locality preserving projections (WLPP), and local feature based on local binary pattern variance and locality preserving projections (LBPV_LPP) have been proposed. Finally, the nearest neighbour matching method has been proposed that verified the test palm vein images. The experimental result shows that the EER to the proposed method is 0.1378%. PMID:24693230

  2. ITER in-vessel system design and performance

    NASA Astrophysics Data System (ADS)

    Parker, R. R.

    2000-03-01

    The article reviews the design and performance of the in-vessel components of ITER as developed for the Engineering Design Activities (EDA) Final Design Report. The double walled vacuum vessel is the first confinement boundary and is designed to maintain its integrity under all normal and off-normal conditions, e.g. the most intense vertical displacement events (VDEs) and seismic events. The shielding blanket consists of modules connected to a toroidal backplate by flexible connectors which allow differential displacements due to temperature non-uniformities. Breeding blanket modules replace the shield modules for the Enhanced Performance Phase. The divertor concept is based on a cassette structure which is convenient for remote installation and removal. High heat flux (HHF) components are mechanically attached and can be removed and replaced in the hot cell. Operation of the divertor is based on achieving partially detached plasma conditions along and near the separatrix. Nominal heat loads of 5-10 MW/m2 are expected on the target. These are accommodated by HHF technology developed during the EDA. Disruptions and VDEs can lead to melting of the first wall armour but no damage to the underlying structure. Stresses in the main structural components remain within allowable ranges for all postulated disruption and seismic events.

  3. Palm vein verification using multiple features and locality preserving projections.

    PubMed

    Al-Juboori, Ali Mohsin; Bu, Wei; Wu, Xiangqian; Zhao, Qiushi

    2014-01-01

    Biometrics is defined as identifying people by their physiological characteristic, such as iris pattern, fingerprint, and face, or by some aspects of their behavior, such as voice, signature, and gesture. Considerable attention has been drawn on these issues during the last several decades. And many biometric systems for commercial applications have been successfully developed. Recently, the vein pattern biometric becomes increasingly attractive for its uniqueness, stability, and noninvasiveness. A vein pattern is the physical distribution structure of the blood vessels underneath a person's skin. The palm vein pattern is very ganglion and it shows a huge number of vessels. The attitude of the palm vein vessels stays in the same location for the whole life and its pattern is definitely unique. In our work, the matching filter method is proposed for the palm vein image enhancement. New palm vein features extraction methods, global feature extracted based on wavelet coefficients and locality preserving projections (WLPP), and local feature based on local binary pattern variance and locality preserving projections (LBPV_LPP) have been proposed. Finally, the nearest neighbour matching method has been proposed that verified the test palm vein images. The experimental result shows that the EER to the proposed method is 0.1378%.

  4. 78 FR 55060 - Proposed Information Collection; Comment Request; Expanded Vessel Monitoring System Requirement...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-09

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration Proposed Information Collection; Comment Request; Expanded Vessel Monitoring System Requirement in the Pacific Coast Groundfish... and use a vessel monitoring system (VMS) that automatically sends hourly position reports. Exemptions...

  5. 76 FR 38598 - Atlantic Highly Migratory Species; Vessel Monitoring Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-01

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration 50 CFR Part 635 RIN 0648-BA64 Atlantic Highly Migratory Species; Vessel Monitoring Systems AGENCY: National Marine Fisheries... on June 21, 2011, concerning modifications to vessel monitoring system (VMS) requirements in Atlantic...

  6. A simplified, low power system for effective vessel sealing

    NASA Astrophysics Data System (ADS)

    Lyle, Allison B.; Kennedy, Jenifer S.; Schmaltz, Dale F.; Kennedy, Aaron S.

    2015-03-01

    The first bipolar vessel sealing system was developed nearly 15 years ago and has since become standard of care in surgery. These systems make use of radio frequency current that is delivered between bipolar graspers to permanently seal arteries, veins and tissue bundles. Conventional vessel sealing generators are based off traditional electrosurgery generator architecture and deliver high power (150-300 Watts) and high current using complex control and sense algorithms to adjust the output for vessel sealing applications. In recent years, a need for small-scale surgical vessel sealers has developed as surgeons strive to further reduce their footprint on patients. There are many technical challenges associated with miniaturization of vessel sealing devices including maintaining electrical isolation while delivering high current in a saline environment. Research into creating a small, 3mm diameter vessel sealer revealed that a highly simplified generator system could be used to achieve excellent results and subsequently a low power vessel sealing system was developed. This system delivers 25 Watts constant power while limiting voltage (<= Vrms) and current (<= Amps) until an impedance endpoint is achieved, eliminating the use of complicated control and sensing software. The result is optimized tissue effect, where high seal strength is maintained (> 360mmHg), but seal times (1.7 +/- 0.7s versus 4.1 +/- 0.7s), thermal spread (<1mm vs <=2mm) and total energy delivery are reduced, when compared to an existing high power system.

  7. 75 FR 1595 - Pacific Halibut Fisheries; Limited Access for Guided Sport Charter Vessels in Alaska

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-12

    ... Halibut Fisheries; Limited Access for Guided Sport Charter Vessels in Alaska AGENCY: National Marine... charter halibut permit under the Limited Access System for Guided Sport Charter Vessels in Alaska... access system for charter vessels in the guided sport fishery for Pacific halibut in waters of...

  8. 33 CFR 96.330 - Document of Compliance certificate: what is it and when is it needed?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS How Will Safety Management Systems Be Certificated and Enforced... freight vessel, freight vessel, or a self-propelled mobile offshore drilling unit of 500 gross tons or...

  9. 33 CFR 96.220 - What makes up a safety management system?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false What makes up a safety management... SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.220 What makes up a safety management system? (a) The...

  10. Forecasting the Risks of Pollution from Ships along the Portuguese Coast

    NASA Astrophysics Data System (ADS)

    Fernandes, Rodrigo; Neves, Ramiro; Lourenço, Filipe; Braunschweig, Frank

    2013-04-01

    Pollution risks in coastal and marine environments are in general based in a static approach, considering historical data, reference situations, and typical scenarios. This approach is quite important in a planning stage. However, an alternative approach can be studied, due to the latest implementation of several different real-time monitoring tools as well as faster performances in the generation of numerical forecasts for metocean properties and trajectories of pollutants spilt at sea or costal zones. These developments provide the possibility of developing an integrated support system for better decision-making in emergency or planning issues associated to pollution risks. An innovative methodology to dynamically produce quantified risks in real-time, integrating best available information from numerical forecasts and the existing monitoring tools, has been developed and applied to the Portuguese Coast. The developed system provides coastal pollution risk levels associated to potential (or real) oil spill incidents from ship collision, grounding or foundering, taking into account regional statistic information on vessel accidents and coastal sensitivity indexes, real-time vessel information (positioning, cargo type, speed and vessel type) obtained from AIS, best-available metocean numerical forecasts (hydrodynamics, meteorology - including visibility, wave conditions) and simulated scenarios by the oil spill fate and behaviour component of MOHID Water Modelling System. Different spill fate and behaviour simulations are continuously generated and processed in background (assuming hypothetical spills from vessels), based on variable vessel information and metocean conditions. Results from these simulations are used in the quantification of consequences of potential spills. All historic information is continuously stored in a database (for risk analysis at a later stage). This dynamic approach improves the accuracy in quantification of consequences to the shoreline, as well as the decision support model, allowing a more effective prioritization of individual ships and geographical areas. This system was initially implemented in Portugal for oil spills. The implementation in other Atlantic Regions (starting in Galician Coast, Spain) is being executed in the scope of ARCOPOL+ project (2011-1/150), as well as other relevant updates. The system is being adapted to include risk modelling of chemical spills, as well as fire & explosion accidents and operational illegal discharges. Also the integration of EMSA's THETIS "ship risk profile" (according to Annex 7 from Paris Memorandum of Understanding) in the risk model is being tested. Finally, a new component is being developed to compute the risk for specific time periods, taking advantage of the information previously stored in the database on the positioning of vessels and / or results of numerical models. This component provides the possibility of obtaining a support tool for detailed characterization of risk profiles in certain periods or a sensitivity analysis on different parameters.

  11. 50 CFR 300.45 - Vessel Monitoring System.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Vessel Monitoring System. 300.45 Section 300.45 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES INTERNATIONAL FISHERIES REGULATIONS South Pacific Tuna Fisheries § 300.45 Vessel Monitoring System. (a) Applicability. Holders of...

  12. 50 CFR 300.45 - Vessel Monitoring System.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 9 2011-10-01 2011-10-01 false Vessel Monitoring System. 300.45 Section 300.45 Wildlife and Fisheries INTERNATIONAL FISHING AND RELATED ACTIVITIES INTERNATIONAL FISHERIES REGULATIONS South Pacific Tuna Fisheries § 300.45 Vessel Monitoring System. (a) Applicability. Holders of...

  13. Completing fishing monitoring with spaceborne Vessel Detection System (VDS) and Automatic Identification System (AIS) to assess illegal fishing in Indonesia.

    PubMed

    Longépé, Nicolas; Hajduch, Guillaume; Ardianto, Romy; Joux, Romain de; Nhunfat, Béatrice; Marzuki, Marza I; Fablet, Ronan; Hermawan, Indra; Germain, Olivier; Subki, Berny A; Farhan, Riza; Muttaqin, Ahmad Deni; Gaspar, Philippe

    2017-10-26

    The Indonesian fisheries management system is now equipped with the state-of-the-art technologies to deter and combat Illegal, Unreported and Unregulated (IUU) fishing. Since October 2014, non-cooperative fishing vessels can be detected from spaceborne Vessel Detection System (VDS) based on high resolution radar imagery, which directly benefits to coordinated patrol vessels in operation context. This study attempts to monitor the amount of illegal fishing in the Arafura Sea based on this new source of information. It is analyzed together with Vessel Monitoring System (VMS) and satellite-based Automatic Identification System (Sat-AIS) data, taking into account their own particularities. From October 2014 to March 2015, i.e. just after the establishment of a new moratorium by the Indonesian authorities, the estimated share of fishing vessels not carrying VMS, thus being illegal, ranges from 42 to 47%. One year later in January 2016, this proportion decreases and ranges from 32 to 42%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Retinal biometrics based on Iterative Closest Point algorithm.

    PubMed

    Hatanaka, Yuji; Tajima, Mikiya; Kawasaki, Ryo; Saito, Koko; Ogohara, Kazunori; Muramatsu, Chisako; Sunayama, Wataru; Fujita, Hiroshi

    2017-07-01

    The pattern of blood vessels in the eye is unique to each person because it rarely changes over time. Therefore, it is well known that retinal blood vessels are useful for biometrics. This paper describes a biometrics method using the Jaccard similarity coefficient (JSC) based on blood vessel regions in retinal image pairs. The retinal image pairs were rough matched by the center of their optic discs. Moreover, the image pairs were aligned using the Iterative Closest Point algorithm based on detailed blood vessel skeletons. For registration, perspective transform was applied to the retinal images. Finally, the pairs were classified as either correct or incorrect using the JSC of the blood vessel region in the image pairs. The proposed method was applied to temporal retinal images, which were obtained in 2009 (695 images) and 2013 (87 images). The 87 images acquired in 2013 were all from persons already examined in 2009. The accuracy of the proposed method reached 100%.

  15. Cerebral amyloid angiopathy, blood-brain barrier disruption and amyloid accumulation in SAMP8 mice.

    PubMed

    del Valle, Jaume; Duran-Vilaregut, Joaquim; Manich, Gemma; Pallàs, Mercè; Camins, Antoni; Vilaplana, Jordi; Pelegrí, Carme

    2011-01-01

    Cerebrovascular dysfunction and β-amyloid peptide deposition on the walls of cerebral blood vessels might be an early event in the development of Alzheimer's disease. Here we studied the time course of amyloid deposition in blood vessels and blood-brain barrier (BBB) disruption in the CA1 subzone of the hippocampus of SAMP8 mice and the association between these two variables. We also studied the association between the amyloid deposition in blood vessels and the recently described amyloid clusters in the parenchyma, as well as the association of these clusters with vessels in which the BBB is disrupted. SAMP8 mice showed greater amyloid deposition in blood vessels than age-matched ICR-CD1 control mice. Moreover, at 12 months of age the number of vessels with a disrupted BBB had increased in both strains, especially SAMP8 animals. At this age, all the vessels with amyloid deposition showed BBB disruption, but several capillaries with an altered BBB showed no amyloid on their walls. Moreover, amyloid clusters showed no spatial association with vessels with amyloid deposition, nor with vessels in which the BBB had been disrupted. Finally, we can conclude that vascular amyloid deposition seems to induce BBB alterations, but BBB disruption may also be due to other factors. Copyright © 2011 S. Karger AG, Basel.

  16. Label-free optical imaging of lymphatic vessels within tissue beds in vivo

    PubMed Central

    Yousefi, Siavash; Zhi, Zhongwei; Wang, Ruikang K.

    2015-01-01

    Lymphatic vessels are a part of circulatory system in vertebrates that maintain tissue fluid homeostasis and drain excess fluid and large cells that cannot easily find their way back into venous system. Due to the lack of non-invasive monitoring tools, lymphatic vessels are known as forgotten circulation. However, lymphatic system plays an important role in diseases such as cancer and inflammatory conditions. In this paper, we start to briefly review the current existing methods for imaging lymphatic vessels, mostly involving dye/targeting cell injection. We then show the capability of optical coherence tomography (OCT) for label-free non-invasive in vivo imaging of lymph vessels and nodes. One of the advantages of using OCT over other imaging modalities is its ability to assess label-free blood flow perfusion that can be simultaneously observed along with lymphatic vessels for imaging the microcirculatory system within tissue beds. Imaging the microcirculatory system including blood and lymphatic vessels can be utilized for imaging and better understanding pathologic mechanisms and treatment technique development in some critical diseases such as inflammation, malignant cancer angiogenesis and metastasis. PMID:25642129

  17. 46 CFR 58.60-3 - Pressure vessel.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU) § 58.60-3 Pressure vessel. A pressure vessel that is a component in an industrial system under this subpart must meet...

  18. 46 CFR 58.60-3 - Pressure vessel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU) § 58.60-3 Pressure vessel. A pressure vessel that is a component in an industrial system under this subpart must meet...

  19. 46 CFR 58.60-3 - Pressure vessel.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU) § 58.60-3 Pressure vessel. A pressure vessel that is a component in an industrial system under this subpart must meet...

  20. 46 CFR 58.60-3 - Pressure vessel.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU) § 58.60-3 Pressure vessel. A pressure vessel that is a component in an industrial system under this subpart must meet...

  1. 46 CFR 58.60-3 - Pressure vessel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU) § 58.60-3 Pressure vessel. A pressure vessel that is a component in an industrial system under this subpart must meet...

  2. Reactor core isolation cooling system

    DOEpatents

    Cooke, F.E.

    1992-12-08

    A reactor core isolation cooling system includes a reactor pressure vessel containing a reactor core, a drywell vessel, a containment vessel, and an isolation pool containing an isolation condenser. A turbine is operatively joined to the pressure vessel outlet steamline and powers a pump operatively joined to the pressure vessel feedwater line. In operation, steam from the pressure vessel powers the turbine which in turn powers the pump to pump makeup water from a pool to the feedwater line into the pressure vessel for maintaining water level over the reactor core. Steam discharged from the turbine is channeled to the isolation condenser and is condensed therein. The resulting heat is discharged into the isolation pool and vented to the atmosphere outside the containment vessel for removing heat therefrom. 1 figure.

  3. Reactor core isolation cooling system

    DOEpatents

    Cooke, Franklin E.

    1992-01-01

    A reactor core isolation cooling system includes a reactor pressure vessel containing a reactor core, a drywell vessel, a containment vessel, and an isolation pool containing an isolation condenser. A turbine is operatively joined to the pressure vessel outlet steamline and powers a pump operatively joined to the pressure vessel feedwater line. In operation, steam from the pressure vessel powers the turbine which in turn powers the pump to pump makeup water from a pool to the feedwater line into the pressure vessel for maintaining water level over the reactor core. Steam discharged from the turbine is channeled to the isolation condenser and is condensed therein. The resulting heat is discharged into the isolation pool and vented to the atmosphere outside the containment vessel for removing heat therefrom.

  4. Growth and regression of vasculature in healthy and diabetic mice after hindlimb ischemia.

    PubMed

    Landázuri, Natalia; Joseph, Giji; Guldberg, Robert E; Taylor, W Robert

    2012-07-01

    The formation of vascular networks during embryogenesis and early stages of development encompasses complex and tightly regulated growth of blood vessels, followed by maturation of some vessels, and spatially controlled disconnection and pruning of others. The adult vasculature, while more quiescent, is also capable of adapting to changing physiological conditions by remodeling blood vessels. Numerous studies have focused on understanding key factors that drive vessel growth in the adult in response to ischemic injury. However, little is known about the extent of vessel rarefaction and its potential contribution to the final outcome of vascular recovery. We addressed this topic by characterizing the endogenous phases of vascular repair in a mouse model of hindlimb ischemia. We showed that this process is biphasic. It encompasses an initial rapid phase of vessel growth, followed by a later phase of vessel rarefaction. In healthy mice, this process resulted in partial recovery of perfusion and completely restored the ability of mice to run voluntarily. Given that the ability to revascularize can be compromised by a cardiovascular risk factor such as diabetes, we also examined vascular repair in diabetic mice. We found that paradoxically both the initial growth and subsequent regression of collateral vessels were more pronounced in the setting of diabetes and resulted in impaired recovery of perfusion and impaired functional status. In conclusion, our findings demonstrate that the formation of functional collateral vessels in the hindlimb requires vessel growth and subsequent vessel rarefaction. In the setting of diabetes, the physiological defect was not in the initial formation of vessels but rather in the inability to sustain newly formed vessels.

  5. Causes and Solutions of the Trampoline Effect.

    PubMed

    Miwa, Masamiki; Ota, Noboru; Ando, Chiyono; Miyazaki, Yukio

    2015-01-01

    A trampoline effect may occur mainly when a buttonhole tract and the vessel flap fail to form a straight line. Certain findings, however, suggest another cause is when the vessel flap is too small. The frequency of the trampoline effect, for example, is lower when a buttonhole tract is created by multiple punctures of the arteriovenous fistula (AVF) vessel than when it is done by one-time puncture of the vessel. Lower frequency of the trampoline effect with multiple punctures of the AVF vessel may be due to enlargement of the initial puncture hole on the vessel every time the vessel is punctured with a sharp needle. Even if aiming at exactly the same point on the AVF vessel every time, the actual puncture point shifts slightly at every puncture, which potentially results in enlargement of the initial hole on the AVF vessel. Moreover, in some patients, continued use of a buttonhole tract for an extended period of time increases the frequency of the trampoline effect. In such cases, reduction of the incidence of the trampoline effect can be achieved by one buttonhole cannulation using a new dull needle with sharp side edges that is used to enlarge the vessel flap. Such single buttonhole cannulation may suggest that the increased frequency of the trampoline effect also potentially occurs in association with gradually diminishing flap size. As a final observation, dull needle insertion into a vessel flap in the reverse direction has been more smoothly achieved than insertion into a vessel flap in the conventional direction. A vessel flap in the reverse direction can be adopted clinically. © 2015 S. Karger AG, Basel.

  6. 33 CFR 96.370 - What are the requirements for vessels of countries not party to Chapter IX of SOLAS?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS How Will Safety Management Systems Be Certificated and... vessel, or self-propelled mobile offshore drilling unit of 500 gross tons or more, operated in U.S...

  7. 33 CFR 96.370 - What are the requirements for vessels of countries not party to Chapter IX of SOLAS?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... vessel, or self-propelled mobile offshore drilling unit of 500 gross tons or more, operated in U.S... Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS How Will Safety Management Systems Be Certificated and...

  8. 46 CFR 67.107 - System of measurement; evidence.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... DOCUMENTATION OF VESSELS Tonnage and Dimension Requirements for Vessel Documentation § 67.107 System of measurement; evidence. (a) The gross and net tonnage and dimensions of a vessel for purposes of this part are...

  9. 46 CFR 67.107 - System of measurement; evidence.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DOCUMENTATION OF VESSELS Tonnage and Dimension Requirements for Vessel Documentation § 67.107 System of measurement; evidence. (a) The gross and net tonnage and dimensions of a vessel for purposes of this part are...

  10. 46 CFR 67.107 - System of measurement; evidence.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... DOCUMENTATION OF VESSELS Tonnage and Dimension Requirements for Vessel Documentation § 67.107 System of measurement; evidence. (a) The gross and net tonnage and dimensions of a vessel for purposes of this part are...

  11. 46 CFR 67.107 - System of measurement; evidence.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... DOCUMENTATION OF VESSELS Tonnage and Dimension Requirements for Vessel Documentation § 67.107 System of measurement; evidence. (a) The gross and net tonnage and dimensions of a vessel for purposes of this part are...

  12. 46 CFR 67.107 - System of measurement; evidence.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... DOCUMENTATION OF VESSELS Tonnage and Dimension Requirements for Vessel Documentation § 67.107 System of measurement; evidence. (a) The gross and net tonnage and dimensions of a vessel for purposes of this part are...

  13. Observational Requirements for Underway Observations from Research Vessels

    NASA Astrophysics Data System (ADS)

    Smith, S. R.; Van Waes, M.

    2016-02-01

    Identifying observational requirements to build and sustain a global ocean observing system requires input from the user community. Research vessels are an essential and versatile component of the observing system. The authors will present results from a survey of the marine climate and oceanographic community that solicited observational requirements for research vessels. The goal of the survey is to determine priorities for underway instrumentation to be run on NOAA vessels operated by the Office of Marine and Aviation Operations (OMAO) to support secondary users of the NOAA fleet. Secondary users are defined as persons that do not routinely participate in cruises on NOAA vessels, but have a research or operational need for underway observations from these vessels. Secondary applications of underway data from NOAA vessels include, but are not limited to, evaluation of analyses/forecast from ocean and atmospheric models, developing satellite retrieval algorithms, and validating observations from remote sensing systems (e.g., satellites, aircraft). For this survey, underway observations are defined as digital data generated by environmental sensor systems permanently installed on the vessel and routinely maintained by the operator. The survey also assessed the need for access to these observations in real-time versus delayed-mode. The authors will discuss how these survey results can be used to inform NOAA management on the requirements for underway observations during future NOAA vessel deployments. Although originally designed to assess requirements for NOAA vessels, the international response to the survey makes the results applicable to research vessel operations around the world.

  14. 46 CFR 27.203 - What are the requirements for fire detection on towing vessels?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... detection on towing vessels? You must have a fire-detection system installed on your vessel to detect engine... use an existing engine-room-monitoring system (with fire-detection capability) instead of a fire-detection system, if the monitoring system is operable and complies with this section. You must ensure that...

  15. 46 CFR 39.1013 - U.S.-flagged tank vessel certification procedures for vapor control system designs-TB/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... vapor control system designs-TB/ALL. 39.1013 Section 39.1013 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS General § 39.1013 U.S.-flagged tank vessel certification procedures for vapor control system designs—TB/ALL. (a) For an existing Coast Guard-approved vapor...

  16. 46 CFR 39.1015 - Foreign-flagged tank vessel certification procedures for vapor control system designs-TB/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... vapor control system designs-TB/ALL. 39.1015 Section 39.1015 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS General § 39.1015 Foreign-flagged tank vessel certification procedures for vapor control system designs—TB/ALL. As an alternative to meeting the requirements...

  17. 46 CFR 39.1015 - Foreign-flagged tank vessel certification procedures for vapor control system designs-TB/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... vapor control system designs-TB/ALL. 39.1015 Section 39.1015 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS General § 39.1015 Foreign-flagged tank vessel certification procedures for vapor control system designs—TB/ALL. As an alternative to meeting the requirements...

  18. 46 CFR 39.1013 - U.S.-flagged tank vessel certification procedures for vapor control system designs-TB/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... vapor control system designs-TB/ALL. 39.1013 Section 39.1013 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS General § 39.1013 U.S.-flagged tank vessel certification procedures for vapor control system designs—TB/ALL. (a) For an existing Coast Guard-approved vapor...

  19. 46 CFR 25.45-1 - Heating and lighting systems on vessels carrying passengers for hire.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Heating and lighting systems on vessels carrying passengers for hire. 25.45-1 Section 25.45-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS Cooking, Heating, and Lighting Systems § 25.45-1 Heating and lighting systems...

  20. Low background techniques and experimental challenges for Borexino and its nylon vessels

    NASA Astrophysics Data System (ADS)

    Pocar, Andrea Pietro

    Borexino is an experiment for low energy (<1 MeV) solar neutrino spectroscopy approaching completion at the underground Gran Sasso laboratories in Italy. It is specifically designed to measure in real time the flux of mono-energetic {berillium} neutrinos produced by fusion reactions in the Sun. Its 300-ton liquid scintillator target is contained in an 8.5 meter diameter nylon inner vessel (IV) and is surrounded by 1000 tons of buffer fluid. A second, 11.5 meter diameter concentric nylon outer vessel (OV) around the IV serves as a barrier for radon emanated at the periphery of the detector. Borexino requires unprecedented low levels of radioactive impurities to be a success (˜1 background event/day in the central 100-tons of scintillator). The IV, which is in direct contact with the scintillator, also has to meet extremely stringent radioactive and cleanliness requirements. Intrinsic levels ˜10 -12 g/g for U and Th and ˜10-8 g/g for K are needed. The vessels, assembled in a clean room in Princeton, made of a 125 micron-thick membrane, need to be leak tight at the 10-2 cc/s and 1 cc/s level for the IV and OV respectively, and have to withstand mechanical stresses due to density differences and temperature gradients between the fluids they contain. Their requirements and assembly process are presented in detail. An upper limit on the inner vessel leak rate of 10-3 cc/s was measured. The performance of a matrix of light sources, placed on both vessels for monitoring its shape with digital cameras, is demonstrated. The problem of surface contamination by radon in the air is extensively addressed, strategies for minimizing it are analysed and the effectiveness of their application evaluated. In particular, an original radon filter based on vacuum swing adsorption on activated charcoal has been developed for use in connection with the clean room. Such a technique yielded radon abatement factors in excess of 104 in a small-scale prototype, and ˜100 in the final system. Finally, trace scintillator radioactivity data are reported from CTF3, a counting test facility for Borexino now in its third data-taking phase. An intrinsic 14C isotopic contamination of the scintillator ˜5 x 10-18 has been measured. Upper limits of ˜3.5 x 10-16 g/g on {\\uranium} contamination and of ˜10 -4 Bq/ton for the 85Kr residual activity have also been set. (Abstract shortened by UMI.)

  1. 75 FR 43487 - Proposed Information Collection; Comment Request; Vessel Monitoring System Requirements in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-26

    ... Monitoring System Requirements in the Western Pacific Pelagic Longline Fishery), OMB Control No. 0648-0519... requirement from OMB Control No. 0648-0584 (Permitting, Vessel Identification and Vessel Monitoring System... one collection (OMB Control No. 0648-0441). II. Method of Collection Automatic. III. Data OMB Control...

  2. 76 FR 26252 - Gulf of Mexico Fishery Management Council; Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-06

    ... Vessel Monitoring System (VMS) Advisory Panel will meet to discuss operation, design, usage of vessel monitoring systems (VMS), and resulting data from these systems. The Advisory Panel will discuss the current.... SUMMARY: The Gulf of Mexico Fishery Management Council will convene a meeting of the Vessel Monitoring...

  3. Label-free optical lymphangiography: development of an automatic segmentation method applied to optical coherence tomography to visualize lymphatic vessels using Hessian filters

    PubMed Central

    Yousefi, Siavash; Qin, Jia; Zhi, Zhongwei

    2013-01-01

    Abstract. Lymphatic vessels are a part of the circulatory system that collect plasma and other substances that have leaked from the capillaries into interstitial fluid (lymph) and transport lymph back to the circulatory system. Since lymph is transparent, lymphatic vessels appear as dark hallow vessel-like regions in optical coherence tomography (OCT) cross sectional images. We propose an automatic method to segment lymphatic vessel lumen from OCT structural cross sections using eigenvalues of Hessian filters. Compared to the existing method based on intensity threshold, Hessian filters are more selective on vessel shape and less sensitive to intensity variations and noise. Using this segmentation technique along with optical micro-angiography allows label-free noninvasive simultaneous visualization of blood and lymphatic vessels in vivo. Lymphatic vessels play an important role in cancer, immune system response, inflammatory disease, wound healing and tissue regeneration. Development of imaging techniques and visualization tools for lymphatic vessels is valuable in understanding the mechanisms and studying therapeutic methods in related disease and tissue response. PMID:23922124

  4. Automatic detection and segmentation of vascular structures in dermoscopy images using a novel vesselness measure based on pixel redness and tubularness

    NASA Astrophysics Data System (ADS)

    Kharazmi, Pegah; Lui, Harvey; Stoecker, William V.; Lee, Tim

    2015-03-01

    Vascular structures are one of the most important features in the diagnosis and assessment of skin disorders. The presence and clinical appearance of vascular structures in skin lesions is a discriminating factor among different skin diseases. In this paper, we address the problem of segmentation of vascular patterns in dermoscopy images. Our proposed method is composed of three parts. First, based on biological properties of human skin, we decompose the skin to melanin and hemoglobin component using independent component analysis of skin color images. The relative quantities and pure color densities of each component were then estimated. Subsequently, we obtain three reference vectors of the mean RGB values for normal skin, pigmented skin and blood vessels from the hemoglobin component by averaging over 100000 pixels of each group outlined by an expert. Based on the Euclidean distance thresholding, we generate a mask image that extracts the red regions of the skin. Finally, Frangi measure was applied to the extracted red areas to segment the tubular structures. Finally, Otsu's thresholding was applied to segment the vascular structures and get a binary vessel mask image. The algorithm was implemented on a set of 50 dermoscopy images. In order to evaluate the performance of our method, we have artificially extended some of the existing vessels in our dermoscopy data set and evaluated the performance of the algorithm to segment the newly added vessel pixels. A sensitivity of 95% and specificity of 87% were achieved.

  5. Containment system for supercritical water oxidation reactor

    DOEpatents

    Chastagner, Philippe

    1994-01-01

    A system for containment of a supercritical water oxidation reactor in the event of a rupture of the reactor. The system includes a containment for housing the reaction vessel and a communicating chamber for holding a volume of coolant, such as water. The coolant is recirculated and sprayed to entrain and cool any reactants that might have escaped from the reaction vessel. Baffles at the entrance to the chamber prevent the sprayed coolant from contacting the reaction vessel. An impact-absorbing layer is positioned between the vessel and the containment to at least partially absorb momentum of any fragments propelled by the rupturing vessel. Remote, quick-disconnecting fittings exterior to the containment, in cooperation with shut-off valves, enable the vessel to be isolated and the system safely taken off-line. Normally-closed orifices throughout the containment and chamber enable decontamination of interior surfaces when necessary.

  6. Containment system for supercritical water oxidation reactor

    DOEpatents

    Chastagner, P.

    1994-07-05

    A system is described for containment of a supercritical water oxidation reactor in the event of a rupture of the reactor. The system includes a containment for housing the reaction vessel and a communicating chamber for holding a volume of coolant, such as water. The coolant is recirculated and sprayed to entrain and cool any reactants that might have escaped from the reaction vessel. Baffles at the entrance to the chamber prevent the sprayed coolant from contacting the reaction vessel. An impact-absorbing layer is positioned between the vessel and the containment to at least partially absorb momentum of any fragments propelled by the rupturing vessel. Remote, quick-disconnecting fittings exterior to the containment, in cooperation with shut-off valves, enable the vessel to be isolated and the system safely taken off-line. Normally-closed orifices throughout the containment and chamber enable decontamination of interior surfaces when necessary. 2 figures.

  7. Apparatus and method for removing solvent from carbon dioxide in resin recycling system

    DOEpatents

    Bohnert, George W [Harrisonville, MO; Hand, Thomas E [Lee's Summit, MO; DeLaurentiis, Gary M [Jamestown, CA

    2009-01-06

    A two-step resin recycling system and method solvent that produces essentially contaminant-free synthetic resin material. The system and method includes one or more solvent wash vessels to expose resin particles to a solvent, the solvent contacting the resin particles in the one or more solvent wash vessels to substantially remove contaminants on the resin particles. A separator is provided to separate the solvent from the resin particles after removal from the one or more solvent wash vessels. The resin particles are next exposed to carbon dioxide in a closed loop carbon dioxide system. The closed loop system includes a carbon dioxide vessel where the carbon dioxide is exposed to the resin, substantially removing any residual solvent remaining on the resin particles after separation. A separation vessel is also provided to separate the solvent from the solvent laden carbon dioxide. Both the carbon dioxide and the solvent are reused after separation in the separation vessel.

  8. Ion transport membrane module and vessel system with directed internal gas flow

    DOEpatents

    Holmes, Michael Jerome; Ohrn, Theodore R.; Chen, Christopher Ming-Poh

    2010-02-09

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an inlet adapted to introduce gas into the interior of the vessel, an outlet adapted to withdraw gas from the interior of the vessel, and an axis; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region; and (c) one or more gas flow control partitions disposed in the interior of the pressure vessel and adapted to change a direction of gas flow within the vessel.

  9. 33 CFR 157.10 - Segregated ballast tanks and crude oil washing systems for certain new vessels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design, Equipment, and Installation § 157.10 Segregated ballast tanks and crude oil washing systems for certain new vessels. (a) This...) Each tank vessel under this section of 20,000 DWT or more that carries crude oil must have a crude oil...

  10. Effect of initial moisture content on the in-vessel composting under air pressure of organic fraction of municipal solid waste in Morocco.

    PubMed

    Makan, Abdelhadi; Assobhei, Omar; Mountadar, Mohammed

    2013-01-03

    This study aimed to evaluate the effect of initial moisture content on the in-vessel composting under air pressure of organic fraction of municipal solid waste in Morocco in terms of internal temperature, produced gases quantity, organic matter conversion rate, and the quality of the final composts.For this purpose, in-vessel bioreactor was designed and used to evaluate both appropriate initial air pressure and appropriate initial moisture content for the composting process. Moreover, 5 experiments were carried out within initial moisture content of 55%, 65%, 70%, 75% and 85%. The initial air pressure and the initial moisture content of the mixture showed a significant effect on the aerobic composting. The experimental results demonstrated that for composting organic waste, relatively high moisture contents are better at achieving higher temperatures and retaining them for longer times.This study suggested that an initial moisture content of around 75%, under 0.6 bar, can be considered as being suitable for efficient composting of organic fraction of municipal solid waste. These last conditions, allowed maximum value of temperature and final composting product with good physicochemical properties as well as higher organic matter degradation and higher gas production. Moreover, final compost obtained showed good maturity levels and can be used for agricultural applications.

  11. Aminopeptidase A is a functional target in angiogenic blood vessels.

    PubMed

    Marchiò, Serena; Lahdenranta, Johanna; Schlingemann, Reinier O; Valdembri, Donatella; Wesseling, Pieter; Arap, Marco A; Hajitou, Amin; Ozawa, Michael G; Trepel, Martin; Giordano, Ricardo J; Nanus, David M; Dijkman, Henri B P M; Oosterwijk, Egbert; Sidman, Richard L; Cooper, Max D; Bussolino, Federico; Pasqualini, Renata; Arap, Wadih

    2004-02-01

    We show that a membrane-associated protease, aminopeptidase A (APA), is upregulated and enzymatically active in blood vessels of human tumors. To gain mechanistic insight, we evaluated angiogenesis in APA null mice. We found that, although these mice develop normally, they fail to mount the expected angiogenic response to hypoxia or growth factors. We then isolated peptide inhibitors of APA from a peptide library and show that they specifically bind to and inhibit APA, suppress migration and proliferation of endothelial cells, inhibit angiogenesis, and home to tumor blood vessels. Finally, we successfully treated tumor-bearing mice with APA binding peptides or anti-APA blocking monoclonal antibodies. These data show that APA is a regulator of blood vessel formation, and can serve as a functional vascular target.

  12. Analysis of artery blood flow before and after angioplasty

    NASA Astrophysics Data System (ADS)

    Tomaszewski, Michał; Baranowski, Paweł; Małachowski, Jerzy; Damaziak, Krzysztof; Bukała, Jakub

    2018-01-01

    The study presents a comparison of results obtained from numerical simulations of blood flow in two different arteries. One of them was considered to be narrowed in order to simulate an arteriosclerosis obstructing the blood flow in the vessel, whereas the second simulates the vessel after angioplasty treatment. During the treatment, a biodegradable stent is inserted into the artery, which prevents the vessel walls from collapsing. The treatment was simulated through the use of numerical simulation using the finite element method. The final mesh geometry obtained from the analysis was exported to the dedicated software in order to create geometry in which a flow domain inside the artery with the stent was created. The flow analysis was conducted in ANSYS Fluent software with non-deformable vessel walls.

  13. 76 FR 50667 - Regulated Navigation Area; Portsmouth Naval Shipyard, Portsmouth, NH

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-16

    ... provide for the safety of life on the navigable waters during ongoing ship construction. DATES: This rule.... ACTION: Temporary final rule. SUMMARY: The Coast Guard is establishing a regulated navigation area on the Piscataqua River near Portsmouth, NH. This temporary final rule places speed restrictions on all vessels...

  14. 78 FR 67326 - Safety and Environmental Management System Requirements for Vessels on the U.S. Outer Continental...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-12

    ... 1625-AC05 Safety and Environmental Management System Requirements for Vessels on the U.S. Outer... ``Safety and Environmental Management System Requirements for Vessels on the U.S. Outer Continental Shelf... of industry to ensure stakeholders have adequate time to submit complete responses. DATES: Comments...

  15. Yakima/Klickitat Production Preliminary Design Report, Appendix C: Yakima and Klickitat Preliminary Engineering Reports.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    CH2M Hill; R.W. Beck and Associates.

    1990-03-01

    This chapter describes the biological and physical fish culture requirements of the hatchery system from which the concepts for the design are formulated. It includes a discussion of the program goals for fish production in the Yakima Basin followed by a brief summary of selected sites. The biological criteria are presented for the water system, adult holding, incubation, rearing, and finally transportation and release. The biological criteria address the water and space requirements, the number and type of vessels, and the related support requirements. To be assured that the components of the system meet all program demands, each life phasemore » from adult capture to the juvenile or smolt transfer into the acclimation sites is analyzed.« less

  16. Bone marrow blood vessel ossification and "microvascular dead space" in rat and human long bone.

    PubMed

    Prisby, Rhonda D

    2014-07-01

    Severe calcification of the bone microvascular network was observed in rats, whereby the bone marrow blood vessels appeared ossified. This study sought to characterize the magnitude of ossification in relation to patent blood vessels and adipocyte content in femoral diaphyses. Additionally, this study confirmed the presence of ossified vessels in patients with arteriosclerotic vascular disease and peripheral vascular disease and cellulitis. Young (4-6 month; n=8) and old (22-24 month; n=8) male Fischer-344 rats were perfused with barium sulfate to visualize patent bone marrow blood vessels. Femoral shafts were processed for bone histomorphometry to quantify ossified (Goldner's Trichrome) and calcified (Alizarin Red) vessels. Adipocyte content was also determined. Additional femora (n=5/age group) were scanned via μCT to quantify microvascular ossification. Bone marrow blood vessels from the rats and the human patients were also isolated and examined via microscopy. Ossified vessels (rats and humans) had osteocyte lacunae on the vessel surfaces and "normal" vessels were transitioning into bone. The volume of ossified vessels was 4800% higher (p<0.05) in the old vs. young rats. Calcified and ossified vessel volumes per tissue volume and calcified vessel volume per patent vessel volume were augmented (p<0.05) 262%, 375% and 263%, respectively, in the old vs. young rats. Ossified and patent vessel number was higher (171%) and lower (40%), respectively, in the old vs. young rats. Finally, adipocyte volume per patent vessel volume was higher (86%) with age. This study is the first to report ossification of bone marrow blood vessels in rats and humans. Ossification presumably results in "microvascular dead space" in regard to loss of patency and vasomotor function as opposed to necrosis. Progression of bone microvascular ossification may provide the common link associated with age-related changes in bone and bone marrow. The clinical implications may be evident in the difficulties treating bone disease in the elderly. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Bone Marrow Blood Vessel Ossification and “Microvascular Dead Space” in Rat and Human Long Bone

    PubMed Central

    Prisby, Rhonda D.

    2014-01-01

    Severe calcification of the bone microvascular network was observed in rats, whereby the bone marrow blood vessels appeared ossified. This study sought to characterize the magnitude of ossification in relation to patent blood vessels and adipocyte content in femoral diaphyses. Additionally, this study confirmed the presence of ossified vessels in patients with arteriosclerotic vascular disease and peripheral vascular disease and cellulitis. Young (4–6 mon; n=8) and old (22–24 mon; n=8) male Fischer-344 rats were perfused with barium sulfate to visualize patent bone marrow blood vessels. Femoral shafts were processed for bone histomorphometry to quantify ossified (Goldner’s Trichrome) and calcified (Alizarin Red) vessels. Adipocyte content was also determined. Additional femora (n=5/age group) were scanned via µCT to quantify microvascular ossification. Bone marrow blood vessels from rats and the human patients were also isolated and examined via microscopy. Ossified vessels (rats and humans) had osteocyte lacunae on the vessel surfaces and “normal” vessels were transitioning into bone. The volume of ossified vessels was 4800% higher (p <0.05) in old vs. young rats. Calcified and ossified vessel volumes per tissue volume and calcified vessel volume per patent vessel volume were augmented (p <0.05) 262%, 375% and 263%, respectively, in old vs. young rats. Ossified and patent vessel number was higher (171%) and lower (40%), respectively, in old vs. young rats. Finally, adipocyte volume per patent vessel volume was higher (86%) with age. This study is the first to report ossification of bone marrow blood vessels in rats and humans. Ossification presumably results in “microvascular dead space” in regards to loss of patency and vasomotor function as opposed to necrosis. The progression of bone microvascular ossification may provide the common link associated with age-related changes in bone and bone marrow. The clinical implications may be evident in the difficulties treating bone disease in the elderly. PMID:24680721

  18. Development of blood vessel searching system for HMS

    NASA Astrophysics Data System (ADS)

    Kandani, Hirofumi; Uenoya, Toshiyuki; Uetsuji, Yasutomo; Nakamachi, Eiji

    2008-08-01

    In this study, we develop a new 3D miniature blood vessel searching system by using near-infrared LED light, a CMOS camera module with an image processing unit for a health monitoring system (HMS), a drug delivery system (DDS) which requires very high performance for automatic micro blood volume extraction and automatic blood examination. Our objective is to fabricate a highly reliable micro detection system by utilizing image capturing, image processing, and micro blood extraction devices. For the searching system to determine 3D blood vessel location, we employ the stereo method. The stereo method is a common photogrammetric method. It employs the optical path principle to detect 3D location of the disparity between two cameras. The principle for blood vessel visualization is derived from the ratio of hemoglobin's absorption of the near-infrared LED light. To get a high quality blood vessel image, we adopted an LED, with peak a wavelength of 940nm. The LED is set on the dorsal side of the finger and it irradiates the human finger. A blood vessel image is captured by a CMOS camera module, which is set below the palmer side of the finger. 2D blood vessel location can be detected by the luminance distribution of a one pixel line. To examine the accuracy of our detecting system, we carried out experiments using finger phantoms with blood vessel diameters of 0.5, 0.75, 1.0mm, at the depths of 0.5 ~ 2.0 mm from the phantom's surface. The experimental results of the estimated depth obtained by our detecting system shows good agreements with the given depths, and the viability of this system is confirmed.

  19. Explosive destruction system for disposal of chemical munitions

    DOEpatents

    Tschritter, Kenneth L [Livermore, CA; Haroldsen, Brent L [Manteca, CA; Shepodd, Timothy J [Livermore, CA; Stofleth, Jerome H [Albuquerque, NM; DiBerardo, Raymond A [Baltimore, MD

    2005-04-19

    An explosive destruction system and method for safely destroying explosively configured chemical munitions. The system comprises a sealable, gas-tight explosive containment vessel, a fragment suppression system positioned in said vessel, and shaped charge means for accessing the interior of the munition when the munition is placed within the vessel and fragment suppression system. Also provided is a means for treatment and neutralization of the munition's chemical fills, and means for heating and agitating the contents of the vessel. The system is portable, rapidly deployable and provides the capability of explosively destroying and detoxifying chemical munitions within a gas-tight enclosure so that there is no venting of toxic or hazardous chemicals during detonation.

  20. Guide for inservice inspection of ground-based pressure vessels and systems

    NASA Technical Reports Server (NTRS)

    1976-01-01

    This guide includes recommendations for inservice inspection and recertification of ground based, unfired pressure vessels and all pressurized systems including those served by fired pressure vessels hereinafter referred to as pressure vessels, systems and components of systems. It covers the vast array of pound based industrial and special purpose pressurized components and systems used at NASA field installations for research and development and those utility systems and components that require more than routine maintenance to insure continued structural integrity for their useful life. Through surveillance and correction of inservice deterioration, NASA will maintain a safe working environment for their own and contractor personnel, safety for the public sector and protection against loss of capital investment.

  1. Autonomic innervation of the fish gut.

    PubMed

    Olsson, Catharina

    2009-01-01

    The enteric nervous system follows a similar overall arrangement in all vertebrate groups. In fish, the majority of nerve cell bodies are found in the myenteric plexus, innervating muscles, blood vessels and glands. In this review, I describe similarities and differences in size, shape and transmitter content in enteric neurons in different fish species and also in comparison with other vertebrates, foremost mammals. The use of different histological and immunochemical methods is reviewed in a historical perspective including advantages and disadvantages of different methods. Lately, zebrafish have become an important model species for developmental studies of the nervous system, including the enteric nervous system, and this is briefly discussed. Finally, examples of how the enteric nervous system controls gut activity in fish is presented, focussing on the effect on gastrointestinal motility.

  2. Fluid-Structure Model of Lymphatic Valve and Vessel

    NASA Astrophysics Data System (ADS)

    Wolf, Ki; Ballard, Matthew; Nepiyushchikh, Zhanna; Razavi, Mohammad; Dixon, Brandon; Alexeev, Alexander

    The lymphatic system is a part of the circulatory system that performs a range of important functions such as transportation of interstitial fluid, fatty acid, and immune cells. The lymphatic vessels are composed of contractile walls to pump lymph against adverse pressure gradient and lymphatic valves that prevent back flow. Despite the importance of lymphatic system, the contribution of mechanical and geometric changes of lymphatic valves and vessels in pathologies of lymphatic dysfunction, such as lymphedema, is not well understood. We developed a coupled fluid-solid computational model to simultaneously simulate a lymphatic vessel, valve, and flow. A lattice Boltzmann model is used to represent the fluid component, while lattice spring model is used for the solid component of the lymphatic vessel, whose mechanical properties are derived experimentally. Behaviors such as lymph flow pattern and lymphatic valve performance against backflow and adverse pressure gradient under varied parameters of lymphatic valve and vessel geometry and mechanical properties are investigated to provide a better insight into the dynamics of lymphatic vessels, valves, and system and give insight into how they might fail in disease. NSF CMMI-1635133.

  3. Numerical investigations on pressurized AL-composite vessel response to hypervelocity impacts: Comparison between experimental works and a numerical code

    NASA Astrophysics Data System (ADS)

    Mespoulet, Jérôme; Plassard, Fabien; Hereil, Pierre-Louis

    2015-09-01

    Response of pressurized composite-Al vessels to hypervelocity impact of aluminum spheres have been numerically investigated to evaluate the influence of initial pressure on the vulnerability of these vessels. Investigated tanks are carbon-fiber overwrapped prestressed Al vessels. Explored internal air pressure ranges from 1 bar to 300 bar and impact velocity are around 4400 m/s. Data obtained from experiments (Xray radiographies, particle velocity measurement and post-mortem vessels) have been compared to numerical results given from LS-DYNA ALE-Lagrange-SPH full coupling models. Simulations exhibit an under estimation in term of debris cloud evolution and shock wave propagation in pressurized air but main modes of damage/rupture on the vessels given by simulations are coherent with post-mortem recovered vessels from experiments. First results of this numerical work are promising and further simulation investigations with additional experimental data will be done to increase the reliability of the simulation model. The final aim of this crossed work is to numerically explore a wide range of impact conditions (impact angle, projectile weight, impact velocity, initial pressure) that cannot be explore experimentally. Those whole results will define a rule of thumbs for the definition of a vulnerability analytical model for a given pressurized vessel.

  4. Estimation of retinal vessel caliber using model fitting and random forests

    NASA Astrophysics Data System (ADS)

    Araújo, Teresa; Mendonça, Ana Maria; Campilho, Aurélio

    2017-03-01

    Retinal vessel caliber changes are associated with several major diseases, such as diabetes and hypertension. These caliber changes can be evaluated using eye fundus images. However, the clinical assessment is tiresome and prone to errors, motivating the development of automatic methods. An automatic method based on vessel crosssection intensity profile model fitting for the estimation of vessel caliber in retinal images is herein proposed. First, vessels are segmented from the image, vessel centerlines are detected and individual segments are extracted and smoothed. Intensity profiles are extracted perpendicularly to the vessel, and the profile lengths are determined. Then, model fitting is applied to the smoothed profiles. A novel parametric model (DoG-L7) is used, consisting on a Difference-of-Gaussians multiplied by a line which is able to describe profile asymmetry. Finally, the parameters of the best-fit model are used for determining the vessel width through regression using ensembles of bagged regression trees with random sampling of the predictors (random forests). The method is evaluated on the REVIEW public dataset. A precision close to the observers is achieved, outperforming other state-of-the-art methods. The method is robust and reliable for width estimation in images with pathologies and artifacts, with performance independent of the range of diameters.

  5. Neutron radiation embrittlement studies in support of continued operation, and validation by sampling of Magnox reactor steel pressure vessels and components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, R.B.; Bolton, C.J.

    1997-02-01

    Magnox steel reactor pressure vessels differ significantly from US LWR vessels in terms of the type of steel used, as well as their operating environment (dose level, exposure temperature range, and neutron spectra). The large diameter ferritic steel vessels are constructed from C-Mn steel plates and forgings joined together with manual metal and submerged-arc welds which are stress-relieved. All Magnox vessels are now at least thirty years old and their continued operation is being vigorously pursued. Vessel surveillance and other programmes are summarized which support this objective. The current understanding of the roles of matrix irradiation damage, irradiation-enhanced copper impuritymore » precipitation and intergranular embrittlement effects is described in so far as these influence the form of the embrittlement and hardening trend curves for each material. An update is given on the influence of high temperature exposure, and on the role of differing neutron spectra. Finally, the validation offered by the results of an initial vessel sampling exercise is summarized together with the objectives of a more extensive future sampling programme.« less

  6. Vessel Monitoring Systems Study. Volume I - Technical Analysis.

    DOT National Transportation Integrated Search

    1980-09-01

    In the Port and Tanker Safety Act of 1978 the U.S. Conress directed the Department of Transportation to performa a study on the desirability and feasibility of a shore-station system for monitoring vessels (including fishing vessels)offshore within t...

  7. 33 CFR 96.200 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.200 Purpose. This subpart establishes the minimum standards that the safety...

  8. 33 CFR 157.146 - Similar tank design: Inspections on U.S. tank vessels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Inspections... Officer in Charge, Marine Inspection, of the zone in which the COW system is inspected, for only one of...

  9. 33 CFR 157.100 - Plans for U.S. tank vessels: Submission.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels General § 157.100 Plans for U.S. tank vessels: Submission. (a) Before each U.S. tank vessel having a COW system under § 157.10(e), § 157.10a(a... submit to the Coast Guard plans that include— (1) A drawing or diagram of the COW pumping and piping...

  10. 33 CFR 104.305 - Vessel Security Assessment (VSA) requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... security; (ii) Structural integrity; (iii) Personnel protection systems; (iv) Procedural policies; (v... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Vessel Security Assessment (VSA... SECURITY MARITIME SECURITY MARITIME SECURITY: VESSELS Vessel Security Assessment (VSA) § 104.305 Vessel...

  11. 33 CFR 104.305 - Vessel Security Assessment (VSA) requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... security; (ii) Structural integrity; (iii) Personnel protection systems; (iv) Procedural policies; (v... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Vessel Security Assessment (VSA... SECURITY MARITIME SECURITY MARITIME SECURITY: VESSELS Vessel Security Assessment (VSA) § 104.305 Vessel...

  12. 33 CFR 104.305 - Vessel Security Assessment (VSA) requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... security; (ii) Structural integrity; (iii) Personnel protection systems; (iv) Procedural policies; (v... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Vessel Security Assessment (VSA... SECURITY MARITIME SECURITY MARITIME SECURITY: VESSELS Vessel Security Assessment (VSA) § 104.305 Vessel...

  13. 33 CFR 104.305 - Vessel Security Assessment (VSA) requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... security; (ii) Structural integrity; (iii) Personnel protection systems; (iv) Procedural policies; (v... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Vessel Security Assessment (VSA... SECURITY MARITIME SECURITY MARITIME SECURITY: VESSELS Vessel Security Assessment (VSA) § 104.305 Vessel...

  14. 33 CFR 104.305 - Vessel Security Assessment (VSA) requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... security; (ii) Structural integrity; (iii) Personnel protection systems; (iv) Procedural policies; (v... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Vessel Security Assessment (VSA... SECURITY MARITIME SECURITY MARITIME SECURITY: VESSELS Vessel Security Assessment (VSA) § 104.305 Vessel...

  15. Endometrial vessel maturation in women exposed to levonorgestrel-releasing intrauterine system for a short or prolonged period of time.

    PubMed

    Stéphanie, Ravet; Labied, Soraya; Blacher, Silvia; Frankenne, Francis; Munaut, Carine; Fridman, Viviana; Beliard, Aude; Foidart, Jean-Michel; Nisolle, Michelle

    2007-12-01

    Levonorgestrel-releasing intrauterine system (LNG-IUS), although inserted to reduce heavy menstruation, causes irregular early transient bleeding. The objective of the study was to document quantitative changes in endometrial vessels of short- (< or =3 months) and long-term (> or =12 months) LNG users. The area, density and maturation of endometrial vessels were quantified in 19 endometrial biopsies of women with LNG-IUS and in 10 normally ovulating patients during mid-luteal phase. Vessel maturation was evaluated by double immunostaining using anti-von Willebrand factor (endothelial cell marker) and anti-alpha Smooth Muscle Actin (vascular smooth muscle cells) antibodies. Vessel area, number and density were quantified with a novel computer-assisted image analysis system. Endometrium exposed to LNG-IUS for 1-3 months displayed a 11.5-fold increase in small naked vessel number. The partially mature vessel (alphaSMA partially positive) number increased six times. After long-term LNG-IUS treatment, the immature and partially mature vessel number remained four times higher than in the control group. Vessel area and density also increased dramatically in a time-dependent pattern with LNG-IUS use. Levonorgestrel affects blood vessel number, area, density and maturation in a time-dependent pattern that may explain the early transient increase in breakthrough bleeding with the LNG-IUS.

  16. Novel algorithm by low complexity filter on retinal vessel segmentation

    NASA Astrophysics Data System (ADS)

    Rostampour, Samad

    2011-10-01

    This article shows a new method to detect blood vessels in the retina by digital images. Retinal vessel segmentation is important for detection of side effect of diabetic disease, because diabetes can form new capillaries which are very brittle. The research has been done in two phases: preprocessing and processing. Preprocessing phase consists to apply a new filter that produces a suitable output. It shows vessels in dark color on white background and make a good difference between vessels and background. The complexity is very low and extra images are eliminated. The second phase is processing and used the method is called Bayesian. It is a built-in in supervision classification method. This method uses of mean and variance of intensity of pixels for calculate of probability. Finally Pixels of image are divided into two classes: vessels and background. Used images are related to the DRIVE database. After performing this operation, the calculation gives 95 percent of efficiency average. The method also was performed from an external sample DRIVE database which has retinopathy, and perfect result was obtained

  17. Histological evaluation and optimization of surgical vessel sealing systems

    NASA Astrophysics Data System (ADS)

    Lathrop, Robert; Ryan, Thomas; Gaspredes, Jonathan; Woloszko, Jean; Coad, James E.

    2017-02-01

    Surgical vessel sealing systems are widely used to achieve hemostasis and dissection in open surgery and minimally invasive, laparoscopic surgery. This enabling technology was developed about 17 years ago and continues to evolve with new devices and systems achieving improved outcomes. Histopathological assessment of thermally sealed tissues is a valuable tool for refining and comparing performance among surgical vessel sealing systems. Early work in this field typically assessed seal time, burst rate, and failure rate (in-situ). Later work compared histological staining methods with birefringence to assess the extent of thermal damage to tissues adjacent to the device. Understanding the microscopic architecture of a sealed vessel is crucial to optimizing the performance of power delivery algorithms and device design parameters. Manufacturers rely on these techniques to develop new products. A system for histopathological evaluation of vessels and sealing performance was established, to enable the direct assessment of a treatment's tissue effects. The parameters included the commonly used seal time, pressure burst rate and failure rate, as well as extensions of the assessment to include its likelihood to form steam vacuoles, adjacent thermal effect near the device, and extent of thermally affected tissue extruded back into the vessel lumen. This comprehensive assessment method provides an improved means of assessing the quality of a sealed vessel and understanding the exact mechanisms which create an optimally sealed vessel.

  18. 46 CFR 97.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Draft marks and draft indicating systems. 97.40-10... VESSELS OPERATIONS Markings on Vessels § 97.40-10 Draft marks and draft indicating systems. (a) All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or...

  19. 46 CFR 196.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Draft marks and draft indicating systems. 196.40-10... VESSELS OPERATIONS Markings on Vessels § 196.40-10 Draft marks and draft indicating systems. (a) All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or...

  20. 46 CFR 97.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Draft marks and draft indicating systems. 97.40-10... VESSELS OPERATIONS Markings on Vessels § 97.40-10 Draft marks and draft indicating systems. (a) All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or...

  1. 46 CFR 97.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Draft marks and draft indicating systems. 97.40-10... VESSELS OPERATIONS Markings on Vessels § 97.40-10 Draft marks and draft indicating systems. (a) All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or...

  2. 46 CFR 196.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Draft marks and draft indicating systems. 196.40-10... VESSELS OPERATIONS Markings on Vessels § 196.40-10 Draft marks and draft indicating systems. (a) All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or...

  3. 46 CFR 97.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Draft marks and draft indicating systems. 97.40-10... VESSELS OPERATIONS Markings on Vessels § 97.40-10 Draft marks and draft indicating systems. (a) All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or...

  4. 46 CFR 196.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Draft marks and draft indicating systems. 196.40-10... VESSELS OPERATIONS Markings on Vessels § 196.40-10 Draft marks and draft indicating systems. (a) All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or...

  5. 46 CFR 97.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Draft marks and draft indicating systems. 97.40-10... VESSELS OPERATIONS Markings on Vessels § 97.40-10 Draft marks and draft indicating systems. (a) All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or...

  6. 46 CFR 196.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Draft marks and draft indicating systems. 196.40-10... VESSELS OPERATIONS Markings on Vessels § 196.40-10 Draft marks and draft indicating systems. (a) All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or...

  7. 46 CFR 196.40-10 - Draft marks and draft indicating systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Draft marks and draft indicating systems. 196.40-10... VESSELS OPERATIONS Markings on Vessels § 196.40-10 Draft marks and draft indicating systems. (a) All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or...

  8. 33 CFR 96.390 - When will the Coast Guard deny entry into a U.S. port?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS How Will Safety Management Systems Be Certificated and Enforced? § 96.390 When will the... force majeure, no vessel shall enter any port or terminal of the U.S. without a safety management system...

  9. 33 CFR 96.390 - When will the Coast Guard deny entry into a U.S. port?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS How Will Safety Management Systems Be Certificated and Enforced? § 96.390 When will the... force majeure, no vessel shall enter any port or terminal of the U.S. without a safety management system...

  10. 33 CFR 157.138 - Crude Oil Washing Operations and Equipment Manual.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Design, Equipment, and... 15 of the MARPOL 73/78. (2) A line drawing of the tank vessel's COW system showing the locations of pumps, piping, and COW machines. (3) A description of the COW system. (4) The procedure for the...

  11. 33 CFR 157.118 - Required documents: Foreign tank vessels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels General § 157.118 Required documents... having a COW system under § 157.10c(b)(2) shall ensure that the vessel does not enter the navigable...) Evidence that the COW system passed the required inspections by— (i) A document from an authorized CS or...

  12. 46 CFR 199.60 - Communications.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Communications. 199.60 Section 199.60 Shipping COAST... SYSTEMS FOR CERTAIN INSPECTED VESSELS Requirements for All Vessels § 199.60 Communications. (a) Radio...) Onboard communications and alarm systems. Each vessel must meet the requirements for onboard...

  13. 46 CFR 199.60 - Communications.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Communications. 199.60 Section 199.60 Shipping COAST... SYSTEMS FOR CERTAIN INSPECTED VESSELS Requirements for All Vessels § 199.60 Communications. (a) Radio...) Onboard communications and alarm systems. Each vessel must meet the requirements for onboard...

  14. 46 CFR 199.60 - Communications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Communications. 199.60 Section 199.60 Shipping COAST... SYSTEMS FOR CERTAIN INSPECTED VESSELS Requirements for All Vessels § 199.60 Communications. (a) Radio...) Onboard communications and alarm systems. Each vessel must meet the requirements for onboard...

  15. 48 CFR 225.7006 - Restriction on air circuit breakers for naval vessels.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Restriction on air circuit breakers for naval vessels. 225.7006 Section 225.7006 Federal Acquisition Regulations System DEFENSE... on air circuit breakers for naval vessels. ...

  16. 48 CFR 225.7006 - Restriction on air circuit breakers for naval vessels.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Restriction on air circuit breakers for naval vessels. 225.7006 Section 225.7006 Federal Acquisition Regulations System DEFENSE... on air circuit breakers for naval vessels. ...

  17. Improvement of retinal blood vessel detection using morphological component analysis.

    PubMed

    Imani, Elaheh; Javidi, Malihe; Pourreza, Hamid-Reza

    2015-03-01

    Detection and quantitative measurement of variations in the retinal blood vessels can help diagnose several diseases including diabetic retinopathy. Intrinsic characteristics of abnormal retinal images make blood vessel detection difficult. The major problem with traditional vessel segmentation algorithms is producing false positive vessels in the presence of diabetic retinopathy lesions. To overcome this problem, a novel scheme for extracting retinal blood vessels based on morphological component analysis (MCA) algorithm is presented in this paper. MCA was developed based on sparse representation of signals. This algorithm assumes that each signal is a linear combination of several morphologically distinct components. In the proposed method, the MCA algorithm with appropriate transforms is adopted to separate vessels and lesions from each other. Afterwards, the Morlet Wavelet Transform is applied to enhance the retinal vessels. The final vessel map is obtained by adaptive thresholding. The performance of the proposed method is measured on the publicly available DRIVE and STARE datasets and compared with several state-of-the-art methods. An accuracy of 0.9523 and 0.9590 has been respectively achieved on the DRIVE and STARE datasets, which are not only greater than most methods, but are also superior to the second human observer's performance. The results show that the proposed method can achieve improved detection in abnormal retinal images and decrease false positive vessels in pathological regions compared to other methods. Also, the robustness of the method in the presence of noise is shown via experimental result. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Vacuum-isolation vessel and method for measurement of thermal noise in microphones

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Ngo, Kim Chi T. (Inventor)

    1992-01-01

    The vacuum isolation vessel and method in accordance with the present invention are used to accurately measure thermal noise in microphones. The apparatus and method could be used in a microphone calibration facility or any facility used for testing microphones. Thermal noise is measured to determine the minimum detectable sound pressure by the microphone. Conventional isolation apparatus and methods have been unable to provide an acoustically quiet and substantially vibration free environment for accurately measuring thermal noise. In the present invention, an isolation vessel assembly comprises a vacuum sealed outer vessel, a vacuum sealed inner vessel, and an interior suspension assembly coupled between the outer and inner vessels for suspending the inner vessel within the outer vessel. A noise measurement system records thermal noise data from the isolation vessel assembly. A vacuum system creates a vacuum between an internal surface of the outer vessel and an external surface of the inner vessel. The present invention thus provides an acoustically quiet environment due to the vacuum created between the inner and outer vessels and a substantially vibration free environment due to the suspension assembly suspending the inner vessel within the outer vessel. The thermal noise in the microphone, effectively isolated according to the invention, can be accurately measured.

  19. Angiotensin II type 1 and 2 receptors and lymphatic vessels modulate lung remodeling and fibrosis in systemic sclerosis and idiopathic pulmonary fibrosis.

    PubMed

    Parra, Edwin Roger; Ruppert, Aline Domingos Pinto; Capelozzi, Vera Luiza

    2014-01-01

    To validate the importance of the angiotensin II receptor isotypes and the lymphatic vessels in systemic sclerosis and idiopathic pulmonary fibrosis. We examined angiotensin II type 1 and 2 receptors and lymphatic vessels in the pulmonary tissues obtained from open lung biopsies of 30 patients with systemic sclerosis and 28 patients with idiopathic pulmonary fibrosis. Their histologic patterns included cellular and fibrotic non-specific interstitial pneumonia for systemic sclerosis and usual interstitial pneumonia for idiopathic pulmonary fibrosis. We used immunohistochemistry and histomorphometry to evaluate the number of cells in the alveolar septae and the vessels stained by these markers. Survival curves were also used. We found a significantly increased percentage of septal and vessel cells immunostained for the angiotensin type 1 and 2 receptors in the systemic sclerosis and idiopathic pulmonary fibrosis patients compared with the controls. A similar percentage of angiotensin 2 receptor positive vessel cells was observed in fibrotic non-specific interstitial pneumonia and usual interstitial pneumonia. A significantly increased percentage of lymphatic vessels was present in the usual interstitial pneumonia group compared with the non-specific interstitial pneumonia and control groups. A Cox regression analysis showed a high risk of death for the patients with usual interstitial pneumonia and a high percentage of vessel cells immunostained for the angiotensin 2 receptor in the lymphatic vessels. We concluded that angiotensin II receptor expression in the lung parenchyma can potentially control organ remodeling and fibrosis, which suggests that strategies aimed at preventing high angiotensin 2 receptor expression may be used as potential therapeutic target in patients with pulmonary systemic sclerosis and idiopathic pulmonary fibrosis.

  20. Visualization of turbulent combustion of TNT detonation products in a steel vessel

    NASA Astrophysics Data System (ADS)

    Wolański, P.; Gut, Z.; Trzciński, W. A.; Szymańczyk, L.; Paszula, J.

    Mixing and afterburning of TNT detonation products in a steel vessel are recorded by the use of the Schlieren visualization system and high speed photography. The vessel is filled with air or 50% oxygen enriched air. Overpressure histories at the vessel wall are also recorded by using pressure transducers. In these experiments nitrogen, air or 50% oxygen enriched air are used as vessel fillers. The Oppenheim-Kuhl theory of thermodynamics of closed systems is applied to estimate the released energy on the basis of pressure histories.

  1. Cryogenic cooler apparatus

    DOEpatents

    Wheatley, J.C.; Paulson, D.N.; Allen, P.C.

    1983-01-04

    A Malone-type final stage for utilization in a Stirling cycle cryogenic cooler apparatus includes a displacer slidable within a vessel. [sup 4]He, [sup 3]He, or a mixture thereof is made to flow in a pulsating unidirectional manner through a regenerator in the displacer by utilization of check valves in separate fluid channels. Stacked copper screen members extend through the channels and through a second static thermodynamic medium within the displacer to provide efficient lateral heat exchange and enable cooling to temperatures in the range of 3--4 K. Another embodiment utilizes sintered copper particles in the regenerator. Also described is a final stage that has a non-thermally conducting displacer having passages with check valves for directing fluid past a regenerator formed in the surrounding vessel. 10 figs.

  2. Cryogenic cooler apparatus

    DOEpatents

    Wheatley, John C.; Paulson, Douglas N.; Allen, Paul C.

    1983-01-01

    A Malone-type final stage for utilization in a Stirling cycle cryogenic cooler apparatus includes a displacer slidable within a vessel. .sup.4 He, .sup.3 He, or a mixture thereof is made to flow in a pulsating unidirectional manner through a regenerator in the displacer by utilization of check valves in separate fluid channels. Stacked copper screen members extend through the channels and through a second static thermodynamic medium within the displacer to provide efficient lateral heat exchange and enable cooling to temperatures in the range of 3-4 K. Another embodiment utilizes sintered copper particles in the regenerator. Also described is a final stage that has a non-thermally conducting displacer having passages with check valves for directing fluid past a regenerator formed in the surrounding vessel.

  3. Final Summary Report on Project 3310 Marine Diesel Exhaust Emissions (Alternative Fuels)

    DTIC Science & Technology

    1997-09-01

    of five types) operating on the West Coast. Of the 14 vessels tested, eight were found to exceed the proposed NOx limits, although some by very small amounts....develop methodology applicable for use on small vessels by using portable emission analyzers, and to examine various potential means of reducing excessive...This report summarizes the results of a 5-year study to ascertain the magnitude of emission problems from Coast Guard and

  4. LANL Robotic Vessel Scanning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webber, Nels W.

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.Themore » project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.« less

  5. 50 CFR 635.69 - Vessel monitoring systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 12 2013-10-01 2013-10-01 false Vessel monitoring systems. 635.69 Section 635.69 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE ATLANTIC HIGHLY MIGRATORY SPECIES Enforcement § 635.69 Vessel monitoring...

  6. 33 CFR 157.172 - Limitations on grades of crude oil carried.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Cow Operations § 157.172 Limitations on grades of crude oil carried. If a tank vessel having a COW system meeting § 157.10a(a)(2) or...

  7. 33 CFR 157.140 - Tank vessel inspections.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Tank vessel inspections. 157.140...) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Inspections § 157.140 Tank vessel inspections. (a) Before...

  8. Processing of Lewisite munitions in the explosive destruction system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shepodd, Timothy J.; Didlake, John E., Jr.; Bradshaw, Robert W., PhD

    2005-03-01

    The Explosive Destruction System (EDS) is a transportable system designed to treat chemical munitions. The EDS is transported on an open trailer that provides a mounting surface for major system components and an operator's work platform. The trailer is towed by a prime mover. An explosive containment vessel contains the shock, munition fragments, and the chemical agent during the munition opening process, and then provides a vessel for the subsequent chemical treatment of the agent. A fragmentation suppression system houses the chemical munition and protects the containment vessel from high velocity fragments. An explosive accessing system uses shaped charges tomore » cut the munition open and attack the burster. A firing system detonates the shaped charges. A chemical feed system supplies neutralizing reagents and water to the containment vessel. A waste handling system drains the treated effluent.« less

  9. Mesquite's Hull is lowered to its final resting place in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Mesquite's Hull is lowered to its final resting place in Lake Superior. The tender ran aground on rocks several months earlier and was battered by winter storms. The wrecked vessel became part of an underwater preserve and is regularly visited by recreational divers - U.S. Coast Guard Cutter MESQUITE, Charlevoix, Charlevoix County, MI

  10. Novel Computerized Method for Measurement of Retinal Vessel Diameters

    PubMed Central

    Guedri, Hichem; Ben Abdallah, Mariem; Echouchene, Fraj; Belmabrouk, Hafedh

    2017-01-01

    Several clinical studies reveal the relationship between alterations in the topologies of the human retinal blood vessel, the outcrop and the disease evolution, such as diabetic retinopathy, hypertensive retinopathy, and macular degeneration. Indeed, the detection of these vascular changes always has gaps. In addition, the manual steps are slow, which may be subjected to a bias of the perceiver. However, we can overcome these troubles using computer algorithms that are quicker and more accurate. This paper presents and investigates a novel method for measuring the blood vessel diameter in the retinal image. The proposed method is based on a thresholding segmentation and thinning step, followed by the characteristic point determination step by the Douglas-Peucker algorithm. Thereafter, it uses the active contours to detect vessel contour. Finally, Heron’s Formula is applied to assure the calculation of vessel diameter. The obtained results for six sample images showed that the proposed method generated less errors compared to other techniques, which confirms the high performance of the proposed method. PMID:28536355

  11. Retinal imaging analysis based on vessel detection.

    PubMed

    Jamal, Arshad; Hazim Alkawaz, Mohammed; Rehman, Amjad; Saba, Tanzila

    2017-07-01

    With an increase in the advancement of digital imaging and computing power, computationally intelligent technologies are in high demand to be used in ophthalmology cure and treatment. In current research, Retina Image Analysis (RIA) is developed for optometrist at Eye Care Center in Management and Science University. This research aims to analyze the retina through vessel detection. The RIA assists in the analysis of the retinal images and specialists are served with various options like saving, processing and analyzing retinal images through its advanced interface layout. Additionally, RIA assists in the selection process of vessel segment; processing these vessels by calculating its diameter, standard deviation, length, and displaying detected vessel on the retina. The Agile Unified Process is adopted as the methodology in developing this research. To conclude, Retina Image Analysis might help the optometrist to get better understanding in analyzing the patient's retina. Finally, the Retina Image Analysis procedure is developed using MATLAB (R2011b). Promising results are attained that are comparable in the state of art. © 2017 Wiley Periodicals, Inc.

  12. Fuel use control in the fishing industry. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Billington, G.

    1985-08-01

    The project undertook fuel flow monitoring of a random sample of fishing vessels in the New Zealand fishing industry. The object of the project was to determine the value of fuel flow measurement on a range of vessels of differing size and fishing method, and to investigate the effect on fuel consumption of hull fouling and propeller repitching where this appeared to be required. Eight vessels in the port of Tauranga were included in the trials. Three of these are company-owned and operated and the remainder are owner-operated. One purse seiner, two longliners and five trawlers (pair and single) weremore » involved. Fuel flow measurements were carried out, with before-and-after tests on one vessel to determine the value of removing hull fouling. In two cases propeller repitching was undertaken. The tests demonstrated that five of the eight vessels could, through minor operational changes, make significant fuel conservation gains with minimal loss of performance.« less

  13. Reliability Analysis of Large Commercial Vessel Engine Room Automation Systems. Volume 1. Results

    DTIC Science & Technology

    1982-11-01

    analyzing the engine room automiations systems on two steam vessels and one diesel vessel, conducting a criticality evaluation, pre- paring...of automated engine room systems,° the effect of *. maintenance was also to be considered, as was the human inter- face and backup. Besides being...designed to replace the human element, the systems periorm more efficiently than the human watchstander. But as with any system, there is no such thing as

  14. Angiogenic and angiostatic factors in the molecular control of angiogenesis.

    PubMed

    Distler, J H W; Hirth, A; Kurowska-Stolarska, M; Gay, R E; Gay, S; Distler, O

    2003-09-01

    The vascular system that ensures an adequate blood flow is required to provide the cells with sufficient supply of nutrients and oxygen. Two different mechanisms of the formation of new vessels can be distinguished: vasculogenesis, the formation of the first primitive vascular plexus de novo and angiogenesis, the formation of new vessels from preexisting ones. Both processes are regulated by a delicate balance of pro- and anti-angiogenic factors. Physiologically, angiostatic mediators outweigh the angiogenic molecules and angiogenesis does not occur. Under certain conditions such as tumor formation or wound healing, the positive regulators of angiogenesis predominate and the endothelium becomes activated. Angiogenesis is initiated by vasodilatation and an increased permeability. After destabilization of the vessel wall, endothelial cells proliferate, migrate and form a tube, which is finally stabilized by pericytes and smooth muscle cells. Numerous soluble growth factors and inhibitors, cytokines and proteases as well as extracellular matrix proteins and adhesion molecules strictly control this multi-step process. The properties and interactions of angiogenic molecules such as VEGFs, FGFs, angiopoietins, PDGF, angiogenin, angiotropin, HGF, CXC chemokines with ELR motif, PECAM-1, integrins and VE-cadherin as well as angiostatic key players such as angiostatin, endostatin, thrombospondin, CXC chemokines without ELR motif, PEDF are discussed in this review with respect to their molecular impact on angiogenesis.

  15. Mechanical behavior of peripheral stents and stent-vessel interaction: A computational study

    NASA Astrophysics Data System (ADS)

    Dottori, Serena; Flamini, Vittoria; Vairo, Giuseppe

    2016-05-01

    In this paper stents employed to treat peripheral artery disease are analyzed through a three-dimensional finite-element approach, based on a large-strain and large-displacement formulation. Aiming to evaluate the influence of some stent design parameters on stent mechanics and on the biomechanical interaction between stent and arterial wall, quasi-static and dynamic numerical analyses are carried out by referring to computational models of commercially and noncommercially available versions of both braided self-expandable stents and balloon-expandable stents. Addressing isolated device models, opening mechanisms and flexibility of both opened and closed stent configurations are numerically experienced. Moreover, stent deployment into a stenotic peripheral artery and possible postdilatation angioplasty (the latter for the self-expandable device only) are simulated by considering different idealized vessel geometries and accounting for the presence of a stenotic plaque. Proposed results highlight important differences in the mechanical response of the two types of stents, as well as a significant influence of the vessel shape on the stress distributions arising upon the artery-plaque system. Finally, computational results are used to assess both the stent mechanical performance and the effectiveness of the stenting treatment, allowing also to identify possible critical conditions affecting the risk of stent fracture, tissue damage, and/or pathological tissue response.

  16. Synthesis of nanostructured barium phosphate and its application in micro-computed tomography of mouse brain vessels in ex vivo

    NASA Astrophysics Data System (ADS)

    Zhu, Bangshang; Yuan, Falei; Yuan, Xiaoya; Bo, Yang; Wang, Yongting; Yang, Guo-Yuan; Drummen, Gregor P. C.; Zhu, Xinyuan

    2014-02-01

    Micro-computed tomography (micro-CT) is a powerful tool for visualizing the vascular systems of tissues, organs, or entire small animals. Vascular contrast agents play a vital role in micro-CT imaging in order to obtain clear and high-quality images. In this study, a new kind of nanostructured barium phosphate was fabricated and used as a contrast agent for ex vivo micro-CT imaging of blood vessels in the mouse brain. Nanostructured barium phosphate was synthesized through a simple wet precipitation method using Ba(NO3)2, and (NH4)2HPO4 as starting materials. The physiochemical properties of barium phosphate were characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, and thermal analysis. Furthermore, the impact of the produced nanostructures on cell viability was evaluated via the MTT assay, which generally showed low to moderate cytotoxicity. Finally, the animal test images demonstrated that the use of nanostructured barium phosphate as a contrast agent in Micro-CT imaging produced sharp images with excellent contrast. Both major vessels and the microvasculature were clearly observable in the imaged mouse brain. Overall, the results indicate that nanostructured barium phosphate is a potential and useful vascular contrast agent for micro-CT imaging.

  17. Vasculitic wheel - an algorithmic approach to cutaneous vasculitides.

    PubMed

    Ratzinger, Gudrun; Zelger, Bettina Gudrun; Carlson, J Andrew; Burgdorf, Walter; Zelger, Bernhard

    2015-11-01

    Previous classifications of vasculitides suffer from several defects. First, classifications may follow different principles including clinicopathologic findings, etiology, pathogenesis, prognosis, or therapeutic options. Second, authors fail to distinguish between vasculitis and coagulopathy. Third, vasculitides are systemic diseases. Organ-specific variations make morphologic findings difficult to compare. Fourth, subtle changes are recognized in the skin, but may be asymptomatic in other organs. Our aim was to use the skin and subcutis as a model and the clinicopathologic correlation as the basic process for classification. We use an algorithmic approach with pattern analysis, which allows for consistent reporting of microscopic findings. We first differentiate between small and medium vessel vasculitis. In the second step, we differentiate the subtypes of small (capillaries versus postcapillary venules) and medium-sized (arterioles/arteries versus veins) vessels. In the final step, we differentiate, according to the predominant cell type, into leukocytoclastic and/or granulomatous vasculitis. Starting from leukocytoclastic vasculitis as a central reaction pattern of cutaneous small/medium vessel vasculitides, its relations or variations may be arranged around it like spokes of a wheel around the hub. This may help establish some basic order in this rather complex realm of cutaneous vasculitides, leading to a better understanding in a complicated field. © 2015 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  18. Cryogenic upgrade of the low heat load liquid helium cryostat used to house the Cryogenic Current Comparator in the Antiproton Decelerator at CERN

    NASA Astrophysics Data System (ADS)

    Lees, A.; Koettig, T.; Fernandes, M.; Tan, J.

    2017-12-01

    The Cryogenic Current Comparator (CCC) and its purpose built cryostat were installed in the low-energy Antiproton Decelerator (AD) at CERN in 2015. A pulse-tube cryocooler recondenses evaporated helium to liquid at 4.2 K filling the helium vessel of the cryostat at an equivalent cooling power of 0.69 W. To reduce the transmission of vibration to the highly sensitive CCC, the titanium support systems of the cryostat were optimized to be as stiff as possible while limiting the transmission of heat to the liquid helium vessel. During operation the liquid helium level in the cryostat was seen to reduce, indicating that heat load was higher than intended. To verify the reason for this additional heat load and improve the cryogenic performance of the cryostat, an upgrade was undertaken during the 2016 technical stop of the AD. This article presents the studies undertaken to understand the thermal performance of the cryostat and details the improvements made to reduce heat load on the liquid helium vessel. Also discussed are the procedures used to reduce the diffusion of helium to the vacuum space through ceramic insulators. Finally the upgraded cryogenic performance of the cryostat is presented.

  19. 76 FR 36314 - Safety Zone; Mile Marker 98.5 West of Harvey Lock Gulf Intracoastal Waterway to Mile Marker 108.5...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-22

    ..., levee system, vessels and tows from destruction, loss or injury due to hazards associated with rising... the general public, levee system, vessels and tows from the hazards associated with rising flood water... system, vessels and tows from destruction, loss or injury due to the hazards associated with rising flood...

  20. Segmentation of hepatic artery in multi-phase liver CT using directional dilation and connectivity analysis

    NASA Astrophysics Data System (ADS)

    Wang, Lei; Schnurr, Alena-Kathrin; Zidowitz, Stephan; Georgii, Joachim; Zhao, Yue; Razavi, Mohammad; Schwier, Michael; Hahn, Horst K.; Hansen, Christian

    2016-03-01

    Segmentation of hepatic arteries in multi-phase computed tomography (CT) images is indispensable in liver surgery planning. During image acquisition, the hepatic artery is enhanced by the injection of contrast agent. The enhanced signals are often not stably acquired due to non-optimal contrast timing. Other vascular structure, such as hepatic vein or portal vein, can be enhanced as well in the arterial phase, which can adversely affect the segmentation results. Furthermore, the arteries might suffer from partial volume effects due to their small diameter. To overcome these difficulties, we propose a framework for robust hepatic artery segmentation requiring a minimal amount of user interaction. First, an efficient multi-scale Hessian-based vesselness filter is applied on the artery phase CT image, aiming to enhance vessel structures with specified diameter range. Second, the vesselness response is processed using a Bayesian classifier to identify the most probable vessel structures. Considering the vesselness filter normally performs not ideally on the vessel bifurcations or the segments corrupted by noise, two vessel-reconnection techniques are proposed. The first technique uses a directional morphological operator to dilate vessel segments along their centerline directions, attempting to fill the gap between broken vascular segments. The second technique analyzes the connectivity of vessel segments and reconnects disconnected segments and branches. Finally, a 3D vessel tree is reconstructed. The algorithm has been evaluated using 18 CT images of the liver. To quantitatively measure the similarities between segmented and reference vessel trees, the skeleton coverage and mean symmetric distance are calculated to quantify the agreement between reference and segmented vessel skeletons, resulting in an average of 0:55+/-0:27 and 12:7+/-7:9 mm (mean standard deviation), respectively.

  1. Mammalian Cardiovascular Patterning as Determined by Hemodynamic Forces and Blood Vessel Genetics

    NASA Astrophysics Data System (ADS)

    Anderson, Gregory Arthur

    Cardiovascular development is a process that involves the timing of multiple molecular events, and numerous subtle three-dimensional conformational changes. Traditional developmental biology techniques have provided large quantities of information as to how these complex organ systems develop. However, the major drawback of the majority of current developmental biological imaging is that they are two-dimensional in nature. It is now well recognized that circulation of blood is required for normal patterning and remodeling of blood vessels. Normal blood vessel formation is dependent upon a complex network of signaling pathways, and genetic mutations in these pathways leads to impaired vascular development, heart failure, and lethality. As such, it is not surprising that mutant mice with aberrant cardiovascular patterning are so common, since normal development requires proper coordination between three systems: the heart, the blood, and the vasculature. This thesis describes the implementation of a three-dimensional imaging technique, optical projection tomography (OPT), in conjunction with a computer-based registration algorithm to statistically analyze developmental differences in groups of wild-type mouse embryos. Embryos that differ by only a few hours' gestational time are shown to have developmental differences in blood vessel formation and heart development progression that can be discerned. This thesis describes how we analyzed mouse models of cardiovascular perturbation by OPT to detect morphological differences in embryonic development in both qualitative and quantitative ways. Both a blood vessel specific mutation and a cardiac specific mutation were analyzed, providing evidence that developmental defects of these types can be quantified. Finally, we describe the implementation of OPT imaging to identify statistically significant phenotypes from three different mouse models of cardiovascular perturbation across a range of developmental time points. Image registration methods, combined with intensity- and deformation-based analyses are described and utilized to fully characterize myosin light chain 2a (Mlc2a), delta-like ligand 4 (Dll4), and Endoglin (Eng) mutant mouse embryos. We show that Eng mutant embryos are statistically similar to the Mlc2a phenotype, confirming that these mouse mutants suffer from a primary cardiac developmental defect. Thus, a loss of hemodynamic force caused by defective pumping of the heart is the primary developmental defect affecting these mice.

  2. 33 CFR 157.110 - Crude Oil Washing Operations and Equipment Manual for foreign tank vessels: Submission.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank...: Submission. If the owner or operator of a foreign tank vessel having a COW system under § 157.10(e), § 157...

  3. Lorentz Force Detuning Analysis of the SNS Accelerating Cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. Mitchell; K. Matsumoto; G. Ciovati

    2001-09-01

    The Spallation Neutron Source (SNS) project incorporates a superconducting radio-frequency (SRF) accelerator for the final section of the pulsed mode linac Cavities with geometrical {beta} values of {beta} = 0.61 and {beta} = 0.81 are utilized in the SRF section, and are constructed out of thin-walled niobium with stiffener rings welded between the cells near the iris. The welded titanium helium vessel and tuner assembly restrains the cavity beam tubes Cavities with {beta} values less than one have relatively steep and flat side-walls making the cavities susceptible to Ised RF induces cyclic Lorentz pressures that mechanically excite the cavities, producingmore » a dynamic Lorentz force detuning different from a continuous RF system. The amplitude of the dynamic detuning for a given cavity design is a function of the mechanical damping, stiffness of the tuner/helium vessel assembly, RF pulse profile, and the RF pulse rate. This paper presents analysis and testing results to date, and indicates areas where more investigation is required.« less

  4. An overview of lymphatic vessels and their emerging role in cardiovascular disease

    PubMed Central

    Jones, Dennis; Min, Wang

    2011-01-01

    Over the past decade, molecular details of lymphatic vessels (lymphatics) have been rapidly acquired due to the identification of lymphatic endothelial-specific markers. Separate from the cardiovascular system, the lymphatic system is also an elaborate network of vessels that are important in normal physiology. Lymphatic vessels have the unique task to regulate fluid homeostasis, assist in immune surveillance, and transport dietary lipids. However, dysfunctional lymphatic vessels can cause pathology, while normal lymphatics can exacerbate pathology. This review summarizes the development and growth of lymphatic vessels in addition to highlighting their critical roles in physiology and pathology. Also, we discuss recent work that suggests a connection between lymphatic dysfunction and cardiovascular disease. PMID:22022141

  5. Predictive simulation of bidirectional Glenn shunt using a hybrid blood vessel model.

    PubMed

    Li, Hao; Leow, Wee Kheng; Chiu, Ing-Sh

    2009-01-01

    This paper proposes a method for performing predictive simulation of cardiac surgery. It applies a hybrid approach to model the deformation of blood vessels. The hybrid blood vessel model consists of a reference Cosserat rod and a surface mesh. The reference Cosserat rod models the blood vessel's global bending, stretching, twisting and shearing in a physically correct manner, and the surface mesh models the surface details of the blood vessel. In this way, the deformation of blood vessels can be computed efficiently and accurately. Our predictive simulation system can produce complex surgical results given a small amount of user inputs. It allows the surgeon to easily explore various surgical options and evaluate them. Tests of the system using bidirectional Glenn shunt (BDG) as an application example show that the results produc by the system are similar to real surgical results.

  6. High temperature cooling system and method

    DOEpatents

    Loewen, Eric P.

    2006-12-12

    A method for cooling a heat source, a method for preventing chemical interaction between a vessel and a cooling composition therein, and a cooling system. The method for cooling employs a containment vessel with an oxidizable interior wall. The interior wall is oxidized to form an oxide barrier layer thereon, the cooling composition is monitored for excess oxidizing agent, and a reducing agent is provided to eliminate excess oxidation. The method for preventing chemical interaction between a vessel and a cooling composition involves introducing a sufficient quantity of a reactant which is reactive with the vessel in order to produce a barrier layer therein that is non-reactive with the cooling composition. The cooling system includes a containment vessel with oxidizing agent and reducing agent delivery conveyances and a monitor of oxidation and reduction states so that proper maintenance of a vessel wall oxidation layer occurs.

  7. Containment vessel drain system

    DOEpatents

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  8. 46 CFR 169.705 - Mooring equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Vessel Control, Miscellaneous Systems, and Equipment § 169.705 Mooring equipment. Each vessel must be fitted with... the size of the vessel and the waters on which it operates. ...

  9. 33 CFR 96.490 - What further obligations exist for an organization if the Coast Guard terminates its authorization?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS Authorization of Recognized... companies and vessels must do to have their safety management systems transferred to another organization...

  10. 33 CFR 96.210 - Who does this subpart apply to?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...? 96.210 Section 96.210 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.210 Who does this subpart apply to? (a) This subpart...

  11. 75 FR 43148 - Gulf of Mexico Fishery Management Council; Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-23

    ...; telephone: (813) 348-1630 x235. SUPPLEMENTARY INFORMATION: The Vessel Monitoring System Advisory Panel will meet to discuss operation, design, agency usage of vessel monitoring systems (VMS), and resulting data.... SUMMARY: The Gulf of Mexico Fishery Management Council will convene a meeting of the Vessel Monitoring...

  12. 75 FR 80469 - Gulf of Mexico Fishery Management Council; Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-22

    ... Management Council; telephone: (813) 348-1630 x235. SUPPLEMENTARY INFORMATION: The Vessel Monitoring System (VMS) Advisory Panel will meet to discuss operation, design, usage of vessel monitoring systems, and.... SUMMARY: The Gulf of Mexico Fishery Management Council will convene a meeting of the Vessel Monitoring...

  13. Changes in gravity inhibit lymphocyte locomotion through type I collagen

    NASA Technical Reports Server (NTRS)

    Pellis, N. R.; Goodwin, T. J.; Risin, D.; McIntyre, B. W.; Pizzini, R. P.; Cooper, D.; Baker, T. L.; Spaulding, G. F.

    1997-01-01

    Immunity relies on the circulation of lymphocytes through many different tissues including blood vessels, lymphatic channels, and lymphoid organs. The ability of lymphocytes to traverse the interstitium in both nonlymphoid and lymphoid tissues can be determined in vitro by assaying their capacity to locomote through Type I collagen. In an attempt to characterize potential causes of microgravity-induced immunosuppression, we investigated the effects of simulated microgravity on human lymphocyte function in vitro using a specialized rotating-wall vessel culture system developed at the Johnson Space Center. This very low shear culture system randomizes gravitational vectors and provides an in vitro approximation of microgravity. In the randomized gravity of the rotating-wall vessel culture system, peripheral blood lymphocytes did not locomote through Type I collagen, whereas static cultures supported normal movement. Although cells remained viable during the entire culture period, peripheral blood lymphocytes transferred to unit gravity (static culture) after 6 h in the rotating-wall vessel culture system were slow to recover and locomote into collagen matrix. After 72 h in the rotating-wall vessel culture system and an additional 72 h in static culture, peripheral blood lymphocytes did not recover their ability to locomote. Loss of locomotory activity in rotating-wall vessel cultures appears to be related to changes in the activation state of the lymphocytes and the expression of adhesion molecules. Culture in the rotating-wall vessel system blunted the ability of peripheral blood lymphocytes to respond to polyclonal activation with phytohemagglutinin. Locomotory response remained intact when peripheral blood lymphocytes were activated by anti-CD3 antibody and interleukin-2 prior to introduction into the rotating-wall vessel culture system. Thus, in addition to the systemic stress factors that may affect immunity, isolated lymphocytes respond to gravitational changes by ceasing locomotion through model interstitium. These in vitro investigations suggest that microgravity induces non-stress-related changes in cell function that may be critical to immunity. Preliminary analysis of locomotion in true microgravity revealed a substantial inhibition of cellular movement in Type I collagen. Thus, the rotating-wall vessel culture system provides a model for analyzing the microgravity-induced inhibition of lymphocyte locomotion and the investigation of the mechanisms related to lymphocyte movement.

  14. Effect of initial moisture content on the in-vessel composting under air pressure of organic fraction of municipal solid waste in Morocco

    PubMed Central

    2013-01-01

    This study aimed to evaluate the effect of initial moisture content on the in-vessel composting under air pressure of organic fraction of municipal solid waste in Morocco in terms of internal temperature, produced gases quantity, organic matter conversion rate, and the quality of the final composts. For this purpose, in-vessel bioreactor was designed and used to evaluate both appropriate initial air pressure and appropriate initial moisture content for the composting process. Moreover, 5 experiments were carried out within initial moisture content of 55%, 65%, 70%, 75% and 85%. The initial air pressure and the initial moisture content of the mixture showed a significant effect on the aerobic composting. The experimental results demonstrated that for composting organic waste, relatively high moisture contents are better at achieving higher temperatures and retaining them for longer times. This study suggested that an initial moisture content of around 75%, under 0.6 bar, can be considered as being suitable for efficient composting of organic fraction of municipal solid waste. These last conditions, allowed maximum value of temperature and final composting product with good physicochemical properties as well as higher organic matter degradation and higher gas production. Moreover, final compost obtained showed good maturity levels and can be used for agricultural applications. PMID:23369502

  15. A robust technique based on VLM and Frangi filter for retinal vessel extraction and denoising.

    PubMed

    Khan, Khan Bahadar; Khaliq, Amir A; Jalil, Abdul; Shahid, Muhammad

    2018-01-01

    The exploration of retinal vessel structure is colossally important on account of numerous diseases including stroke, Diabetic Retinopathy (DR) and coronary heart diseases, which can damage the retinal vessel structure. The retinal vascular network is very hard to be extracted due to its spreading and diminishing geometry and contrast variation in an image. The proposed technique consists of unique parallel processes for denoising and extraction of blood vessels in retinal images. In the preprocessing section, an adaptive histogram equalization enhances dissimilarity between the vessels and the background and morphological top-hat filters are employed to eliminate macula and optic disc, etc. To remove local noise, the difference of images is computed from the top-hat filtered image and the high-boost filtered image. Frangi filter is applied at multi scale for the enhancement of vessels possessing diverse widths. Segmentation is performed by using improved Otsu thresholding on the high-boost filtered image and Frangi's enhanced image, separately. In the postprocessing steps, a Vessel Location Map (VLM) is extracted by using raster to vector transformation. Postprocessing steps are employed in a novel way to reject misclassified vessel pixels. The final segmented image is obtained by using pixel-by-pixel AND operation between VLM and Frangi output image. The method has been rigorously analyzed on the STARE, DRIVE and HRF datasets.

  16. 33 CFR 104.245 - Communications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Communications. 104.245 Section... MARITIME SECURITY: VESSELS Vessel Security Requirements § 104.245 Communications. (a) The Vessel Security... board the vessel. (b) Communications systems and procedures must allow effective and continuous...

  17. 33 CFR 104.245 - Communications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Communications. 104.245 Section... MARITIME SECURITY: VESSELS Vessel Security Requirements § 104.245 Communications. (a) The Vessel Security... board the vessel. (b) Communications systems and procedures must allow effective and continuous...

  18. 46 CFR 27.101 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS TOWING VESSELS General Provisions for Fire-Protection... the Commandant; (2) A manually-operated clean-agent system that satisfies the National Fire Protection... or coastal service. Towing vessel in ocean or coastal service means a towing vessel that operates...

  19. 33 CFR 104.245 - Communications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Communications. 104.245 Section... MARITIME SECURITY: VESSELS Vessel Security Requirements § 104.245 Communications. (a) The Vessel Security... board the vessel. (b) Communications systems and procedures must allow effective and continuous...

  20. 33 CFR 104.245 - Communications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Communications. 104.245 Section... MARITIME SECURITY: VESSELS Vessel Security Requirements § 104.245 Communications. (a) The Vessel Security... board the vessel. (b) Communications systems and procedures must allow effective and continuous...

  1. Translational neurocardiology: preclinical models and cardioneural integrative aspects

    PubMed Central

    Andresen, M. C.; Armour, J. A.; Billman, G. E.; Chen, P.‐S.; Foreman, R. D.; Herring, N.; O'Leary, D. S.; Sabbah, H. N.; Schultz, H. D.; Sunagawa, K.; Zucker, I. H.

    2016-01-01

    Abstract Neuronal elements distributed throughout the cardiac nervous system, from the level of the insular cortex to the intrinsic cardiac nervous system, are in constant communication with one another to ensure that cardiac output matches the dynamic process of regional blood flow demand. Neural elements in their various ‘levels’ become differentially recruited in the transduction of sensory inputs arising from the heart, major vessels, other visceral organs and somatic structures to optimize neuronal coordination of regional cardiac function. This White Paper will review the relevant aspects of the structural and functional organization for autonomic control of the heart in normal conditions, how these systems remodel/adapt during cardiac disease, and finally how such knowledge can be leveraged in the evolving realm of autonomic regulation therapy for cardiac therapeutics. PMID:27098459

  2. Commercial Vessel Safety Economic Benefits.

    DTIC Science & Technology

    1980-02-01

    AD-A09b 319 PRC SYSTEMS SERVICES CO MELEAN VA F/S 5/4 CMOMERCIAL VESSEL SAFET Y ECONOM IC BENEFITS (U) FEB Al C A CROOK , W R WHITTEMORE , M MARR5 DOT...N ., . . i* . .... ........ ’q m m l w ’ .. ... .... . .J F Y* •LEVEV teprt N. CB-ID-2-81 Commercial Vessel Safety Economic Benefits PRELIMINARY PRC...constitute endorsement or approval of such products. COMMERCIAL VESSEL SAFETY ECONOMIC BENEFITS PRC Systems Services Company 7600 Old Springhouse

  3. Diaphragmatic lymphatic vessel behavior during local skeletal muscle contraction.

    PubMed

    Moriondo, Andrea; Solari, Eleonora; Marcozzi, Cristiana; Negrini, Daniela

    2015-02-01

    The mechanism through which the stresses developed in the diaphragmatic tissue during skeletal muscle contraction sustain local lymphatic function was studied in 10 deeply anesthetized, tracheotomized adult Wistar rats whose diaphragm was exposed after thoracotomy. To evaluate the direct effect of skeletal muscle contraction on the hydraulic intraluminal lymphatic pressures (Plymph) and lymphatic vessel geometry, the maximal contraction of diaphragmatic fibers adjacent to a lymphatic vessel was elicited by injection of 9.2 nl of 1 M KCl solution among diaphragmatic fibers while Plymph was recorded through micropuncture and vessel geometry via stereomicroscopy video recording. In lymphatics oriented perpendicularly to the longitudinal axis of muscle fibers and located at <300 μm from KCl injection, vessel diameter at maximal skeletal muscle contraction (Dmc) decreased to 61.3 ± 1.4% of the precontraction value [resting diameter (Drest)]; however, if injection was at >900 μm from the vessel, Dmc enlarged to 131.1 ± 2.3% of Drest. In vessels parallel to muscle fibers, Dmc increased to 122.8 ± 2.9% of Drest. During contraction, Plymph decreased as much as 22.5 ± 2.6 cmH2O in all submesothelial superficial vessels, whereas it increased by 10.7 ± 5.1 cmH2O in deeper vessels running perpendicular to contracting muscle fibers. Hence, the three-dimensional arrangement of the diaphragmatic lymphatic network seems to be finalized to efficiently exploit the stresses exerted by muscle fibers during the contracting inspiratory phase to promote lymph formation in superficial submesothelial lymphatics and its further propulsion in deeper intramuscular vessels. Copyright © 2015 the American Physiological Society.

  4. Deposition of collagen type I onto skeletal endothelium reveals a new role for blood vessels in regulating bone morphology

    PubMed Central

    Ben Shoham, Adi; Rot, Chagai; Stern, Tomer; Krief, Sharon; Akiva, Anat; Dadosh, Tali; Sabany, Helena; Lu, Yinhui; Kadler, Karl E.

    2016-01-01

    Recently, blood vessels have been implicated in the morphogenesis of various organs. The vasculature is also known to be essential for endochondral bone development, yet the underlying mechanism has remained elusive. We show that a unique composition of blood vessels facilitates the role of the endothelium in bone mineralization and morphogenesis. Immunostaining and electron microscopy showed that the endothelium in developing bones lacks basement membrane, which normally isolates the blood vessel from its surroundings. Further analysis revealed the presence of collagen type I on the endothelial wall of these vessels. Because collagen type I is the main component of the osteoid, we hypothesized that the bone vasculature guides the formation of the collagenous template and consequently of the mature bone. Indeed, some of the bone vessels were found to undergo mineralization. Moreover, the vascular pattern at each embryonic stage prefigured the mineral distribution pattern observed one day later. Finally, perturbation of vascular patterning by overexpressing Vegf in osteoblasts resulted in abnormal bone morphology, supporting a role for blood vessels in bone morphogenesis. These data reveal the unique composition of the endothelium in developing bones and indicate that vascular patterning plays a role in determining bone shape by forming a template for deposition of bone matrix. PMID:27621060

  5. Enhanced Expression of CD13 in Vessels of Inflammatory and Neoplastic Tissues

    PubMed Central

    Matteo, Paola Di; Arrigoni, Gian Luigi; Alberici, Luca; Corti, Angelo; Gallo-Stampino, Corrado; Traversari, Catia; Doglioni, Claudio; Rizzardi, Gian-Paolo

    2011-01-01

    Aminopeptidase-N (CD13) is an important target of tumor vasculature-targeting drugs. The authors investigated its expression by immunohistochemistry with three anti-CD13 monoclonal antibodies (WM15, 3D8, and BF10) in normal and pathological human tissues, including 58 normal, 32 inflammatory, and 149 tumor tissue specimens. The three antibodies stained vessels in most neoplastic tissues, interestingly with different patterns. As a matter of fact, WM15 stained almost all intratumor and peritumor capillaries and only partially large vessels, whereas BF10 and 3D8 reacted with arteries and venules and to a lesser extent with capillaries. These antibodies also stained the stroma in about half of neoplastic tissues. In inflammatory lesions, the three antibodies stained vessels and stroma, whereas in normal tissues, they stained a small percentage of blood vessels. Finally, the three antibodies failed to stain endothelial cells of normal colon, whereas they reacted with activated human umbilical vein endothelial cells and with endothelial cells of colon adenocarcinoma vessels. Overall, WM15 was the most specific antibody for angiogenic tumor vessels, suggesting that it may be a good tool for detecting the CD13 form associated with the tumor vasculature. This finding may be relevant for CD13-mediated vascular targeting therapies. PMID:21339174

  6. Assembly & Metrology of First Wall Components of SST-1

    NASA Astrophysics Data System (ADS)

    Parekh, Tejas; Santra, Prosenjit; Biswas, Prabal; Patel, Hiteshkumar; Paravastu, Yuvakiran; Jaiswal, Snehal; Chauhan, Pradeep; Babu, Gattu Ramesh; A, Arun Prakash; Bhavsar, Dhaval; Raval, Dilip C.; Khan, Ziauddin; Pradhan, Subrata

    2017-04-01

    First Wall Components (FWC) of SST-1 tokamak, which are in the immediate vicinity of plasma comprises of limiters, divertors, baffles, passive stabilizers are designed to operate long duration (1000 s) discharges of elongated plasma. All FWC consists of a copper alloy heat sink modules with SS cooling tubes brazed onto it, graphite tiles acting as armour material facing the plasma, and are mounted to the vacuum vessels with suitable Inconel support structures at ring & port locations. The FWC are very recently assembled and commissioned successfully inside the vacuum vessel of SST-1 undergoing a meticulous planning of assembly sequence, quality checks at every stage of the assembly process. This paper will present the metrology aspects & procedure of each FWC, both outside the vacuum vessel, and inside the vessel, assembly tolerances, tools, equipment and jig/fixtures, used at each stage of assembly, starting from location of support bases on vessel rings, fixing of copper modules on support structures, around 3800 graphite tile mounting on 136 copper modules with proper tightening torques, till final toroidal and poloidal geometry of the in-vessel components are obtained within acceptable limits, also ensuring electrical continuity of passive stabilizers to form a closed saddle loop, electrical isolation of passive stabilizers from vacuum vessel.

  7. Tracking Vessels to Illegal Pollutant Discharges Using Multisource Vessel Information

    NASA Astrophysics Data System (ADS)

    Busler, J.; Wehn, H.; Woodhouse, L.

    2015-04-01

    Illegal discharge of bilge waters is a significant source of oil and other environmental pollutants in Canadian and international waters. Imaging satellites are commonly used to monitor large areas to detect oily discharges from vessels, off-shore platforms and other sources. While remotely sensed imagery provides a snap-shot picture useful for detecting a spill or the presence of vessels in the vicinity, it is difficult to directly associate a vessel to an observed spill unless the vessel is observed while the discharge is occurring. The situation then becomes more challenging with increased vessel traffic as multiple vessels may be associated with a spill event. By combining multiple sources of vessel location data, such as Automated Information Systems (AIS), Long Range Identification and Tracking (LRIT) and SAR-based ship detection, with spill detections and drift models we have created a system that associates detected spill events with vessels in the area using a probabilistic model that intersects vessel tracks and spill drift trajectories in both time and space. Working with the Canadian Space Agency and the Canadian Ice Service's Integrated Satellite Tracking of Pollution (ISTOP) program, we use spills observed in Canadian waters to demonstrate the investigative value of augmenting spill detections with temporally sequenced vessel and spill tracking information.

  8. Heating and cooling system for an on-board gas adsorbent storage vessel

    DOEpatents

    Tamburello, David A.; Anton, Donald L.; Hardy, Bruce J.; Corgnale, Claudio

    2017-06-20

    In one aspect, a system for controlling the temperature within a gas adsorbent storage vessel of a vehicle may include an air conditioning system forming a continuous flow loop of heat exchange fluid that is cycled between a heated flow and a cooled flow. The system may also include at least one fluid by-pass line extending at least partially within the gas adsorbent storage vessel. The fluid by-pass line(s) may be configured to receive a by-pass flow including at least a portion of the heated flow or the cooled flow of the heat exchange fluid at one or more input locations and expel the by-pass flow back into the continuous flow loop at one or more output locations, wherein the by-pass flow is directed through the gas adsorbent storage vessel via the by-pass line(s) so as to adjust an internal temperature within the gas adsorbent storage vessel.

  9. Biology of Bone: The Vasculature of the Skeletal System.

    PubMed

    Watson, Emma C; Adams, Ralf H

    2017-09-11

    Blood vessels are essential for the distribution of oxygen, nutrients, and immune cells, as well as the removal of waste products. In addition to this conventional role as a versatile conduit system, the endothelial cells forming the innermost layer of the vessel wall also possess important signaling capabilities and can control growth, patterning, homeostasis, and regeneration of the surrounding organ. In the skeletal system, blood vessels regulate developmental and regenerative bone formation as well as hematopoiesis by providing vascular niches for hematopoietic stem cells. Here we provide an overview of blood vessel architecture, growth and properties in the healthy, aging, and diseased skeletal system. Copyright © 2017 Cold Spring Harbor Laboratory Press; all rights reserved.

  10. Fracture Test Methods for Plastically Responding COPV Liners

    NASA Technical Reports Server (NTRS)

    Dawicke, David S.; Lewis, Joseph C.

    2009-01-01

    An experimental procedure for evaluating the validity of using uniaxial tests to provide a conservative bound on the fatigue crack growth rate behavior small cracks in bi-axially loaded Composite Overwrapped Pressure Vessel (COPV) liners is described. The experimental procedure included the use of a laser notch to quickly generate small surface fatigue cracks with the desired size and aspect ratios. An out-of-plane constraint system was designed to allow fully reversed, fully plastic testing of thin sheet uniaxial coupons. Finally, a method was developed to determine to initiate small cracks in the liner of COPVs.

  11. 76 FR 66927 - New York State Prohibition of Discharges of Vessel Sewage; Final Affirmative Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-28

    .... 1322(f)(3)), the State of New York has determined that the protection and enhancement of the quality of... certified the need for greater protection of the water quality. EPA hereby makes a final affirmative... commenters pointed out that this action will reduce pathogens and chemicals, improve water quality and...

  12. 29 CFR 1915.93 - Utilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... shall ascertain from responsible vessel's representatives, having knowledge of the condition of the... power. (1) When the vessel is supplied with electric power from a source outside the vessel, the... representatives, having knowledge of the condition of the vessel's electrical system, that all circuits to be...

  13. 46 CFR 112.43-5 - Controls on island type vessels.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Controls on island type vessels. 112.43-5 Section 112.43-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-5 Controls on island type vessels. On an...

  14. 46 CFR 112.43-5 - Controls on island type vessels.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Controls on island type vessels. 112.43-5 Section 112.43-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-5 Controls on island type vessels. On an...

  15. 46 CFR 112.43-5 - Controls on island type vessels.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Controls on island type vessels. 112.43-5 Section 112.43-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-5 Controls on island type vessels. On an...

  16. 46 CFR 112.43-5 - Controls on island type vessels.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Controls on island type vessels. 112.43-5 Section 112.43-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-5 Controls on island type vessels. On an...

  17. 46 CFR 112.43-5 - Controls on island type vessels.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Controls on island type vessels. 112.43-5 Section 112.43-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-5 Controls on island type vessels. On an...

  18. Considerations for acoustic emission monitoring of spherical Kevlar/epoxy composite pressure vessels

    NASA Technical Reports Server (NTRS)

    Hamstad, M. A.; Patterson, R. G.

    1977-01-01

    We are continuing to research the applications of acoustic emission testing for predicting burst pressure of filament-wound Kevlar 49/epoxy pressure vessels. This study has focused on three specific areas. The first area involves development of an experimental technique and the proper instrumentation to measure the energy given off by the acoustic emission transducer per acoustic emission burst. The second area concerns the design of a test fixture in which to mount the composite vessel so that the acoustic emission transducers are held against the outer surface of the composite. Included in this study area is the calibration of the entire test setup including couplant, transducer, electronics, and the instrument measuring the energy per burst. In the third and final area of this study, we consider the number, location, and sensitivity of the acoustic emission transducers used for proof testing composite pressure vessels.

  19. Pattern Recognition Of Blood Vessel Networks In Ocular Fundus Images

    NASA Astrophysics Data System (ADS)

    Akita, K.; Kuga, H.

    1982-11-01

    We propose a computer method of recognizing blood vessel networks in color ocular fundus images which are used in the mass diagnosis of adult diseases such as hypertension and diabetes. A line detection algorithm is applied to extract the blood vessels, and the skeleton patterns of them are made to analyze and describe their structures. The recognition of line segments of arteries and/or veins in the vessel networks consists of three stages. First, a few segments which satisfy a certain constraint are picked up and discriminated as arteries or veins. This is the initial labeling. Then the remaining unknown ones are labeled by utilizing the physical level knowledge. We propose two schemes for this stage : a deterministic labeling and a probabilistic relaxation labeling. Finally the label of each line segment is checked so as to minimize the total number of labeling contradictions. Some experimental results are also presented.

  20. Development of portable health monitoring system for automatic self-blood glucose measurement

    NASA Astrophysics Data System (ADS)

    Kim, Huijun; Mizuno, Yoshihumi; Nakamachi, Eiji; Morita, Yusuke

    2010-02-01

    In this study, a new HMS (Health Monitoring System) device is developed for diabetic patient. This device mainly consists of I) 3D blood vessel searching unit and II) automatic blood glucose measurement (ABGM) unit. This device has features such as 1)3D blood vessel location search 2) laptop type, 3) puncturing a blood vessel by using a minimally invasive micro-needle, 4) very little blood sampling (10μl), and 5) automatic blood extraction and blood glucose measurement. In this study, ABGM unit is described in detail. It employs a syringe type's blood extraction mechanism because of its high accuracy. And it consists of the syringe component and the driving component. The syringe component consists of a syringe itself, a piston, a magnet, a ratchet and a micro-needle whose inner diameter is about 80μm. And the syringe component is disposable. The driving component consists of body parts, a linear stepping motor, a glucose enzyme sensor and a slider for accurate positioning control. The driving component has the all-in-one mechanism with a glucose enzyme sensor for compact size and stable blood transfer. On designing, required thrust force to drive the slider is designed to be greater than the value of the blood extraction force. Further, only one linear stepping motor is employed for blood extraction and transportation processes. The experimental result showed more than 80% of volume ratio under the piston speed 2.4mm/s. Further, the blood glucose was measured successfully by using the prototype unit. Finally, the availability of our ABGM unit was confirmed.

  1. Microfabrication of channel arrays promotes vessel-like network formation in cardiac cell construct and vascularization in vivo.

    PubMed

    Zieber, Liran; Or, Shira; Ruvinov, Emil; Cohen, Smadar

    2014-06-01

    Pre-vascularization is important for the reconstruction of dense and metabolically active myocardial tissue and its integration with the host myocardium after implantation. Herein, we demonstrate that the fabrication of micro-channels in alginate scaffold combined with the presentation of adhesion peptides and an angiogenic growth factor promote vessel-like networks in the construct, both in vitro and in vivo. Using a CO2 laser engraving system, 200 µm diameter channels were formed from top to bottom of the 2 mm thick alginate scaffold, with a channel-to-channel distance of 400 µm. Cells were seeded in a sequential manner onto the scaffolds: first, human umbilical vascular endothelial cells (HUVECs) were seeded and cultured for three days, then neonatal rat cardiomyocytes (CMs) and cardiofibroblasts were added at a final cell ratio of 50:35:15, respectively, and the constructs were cultivated for an additional seven days. A vessel-like network was formed within the cell constructs, wherein HUVECs were organized around the channels in a multilayer manner, while the CMs were located in-between the channels and exhibited the characteristic morphological features of a mature cardiac fiber. Acellular scaffolds with the affinity-bound basic fibroblast growth factor were implanted subcutaneously in mice. Increased cell penetration into the channeled scaffold and greater vessel density were found in comparison with the nonchanneled scaffolds. Our results thus point to the importance of micro-channels as a major structural promoter of vascularization in scaffolds, in conjunction with the sequential preculture of ECs and angiogenic factor presentation.

  2. Myoblast-mediated gene transfer for therapeutic angiogenesis and arteriogenesis.

    PubMed

    von Degenfeld, Georges; Banfi, Andrea; Springer, Matthew L; Blau, Helen M

    2003-10-01

    Therapeutic angiogenesis aims at generating new blood vessels by delivering growth factors such as VEGF and FGF. Clinical trials are underway in patients with peripheral vascular and coronary heart disease. However, increasing evidence indicates that the new vasculature needs to be stabilized to avoid deleterious effects such as edema and hemangioma formation. Moreover, a major challenge is to induce new vessels that persist following cessation of the angiogenic stimulus. Mature vessels may be generated by modulating timing and dosage of growth factor expression, or by combination of 'growth' factors with 'maturation' factors like PDGF-BB, angiopoietin-1 or TGF-beta. Myoblast-mediated gene transfer has unique characteristics that make it a useful tool for studying promising novel approaches to therapeutic angiogenesis. It affords robust and long-lasting expression, and can be considered as a relatively rapid form of 'adult transgenesis' in muscle. The combined insertion of different gene constructs into single myoblasts and their progeny allows the simultaneous expression of different 'growth' and 'maturation' factors within the same cell in vivo. The additional insertion of a reporter gene makes it possible to analyze the phenotype of the vessels surrounding the transgenic muscle fibers into which the myoblasts have fused. The effects of timing and duration of gene expression can be studied by using tetracycline-inducible constructs, and dosage effects by selecting subpopulations consistently expressing distinct levels of growth factors. Finally, the autologous cell-based approach using transduced myoblasts could be an alternative gene delivery system for therapeutic angiogenesis in patients, avoiding the toxicities seen with some viral vectors.

  3. 33 CFR 157.130 - Crude oil washing with more than one grade of crude oil.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Design... vessel having a COW system under §§ 157.10(e), 157.10a(a)(2), or 157.10c(b)(2) carries more than one grade of crude oil, the COW system must be capable of washing the cargo tanks with the grades of crude...

  4. Lessons From the Pioneer Venus Program

    NASA Technical Reports Server (NTRS)

    Dorfman, Steven D.

    2005-01-01

    We began the Pioneer Venus contract in late 1974 with a planned launch of the Orbiter in May 1978 and the Multiprobe in August 1978. Because we had four years, we thought there was plenty of time. As it turned out, we barely made the launch dates. The Orbiter was relatively straightforward, compared to the Multiprobe Bus and Probes that had to survive descent through the harsh Venusian atmosphere. To help overcome our many Multiprobe problems we formed a strong global team. The GE reentry team in Philadelphia, experienced in designing vehicles to enter the earth s atmosphere, was assigned the responsibility for the Probe entry system, including protective heat shielding and parachute design to extract the scienceladen Large Probe pressure vessel and control its descent through the Venusian clouds. Since the Probes had to remain stable as they descended through the Venus atmosphere, we used the aerodynamic expertise at the Hughes Missile Division, NASA s Ames Research Center and the Langley Research Center. Since the pressure at the surface of Venus was equivalent to an ocean depth of 3300 feet, we went to the Navy s David Taylor Research Center for their deepsea expertise. To test the pressure vessel at the high pressure and temperatures anticipated at Venus we went to the only facility capable of simulating the Venus surface environment, the Southwest Research Institute in San Antonio, Texas. We had dozens of subcontractors all over the world. As we developed our design, we began an extensive program to validate the ability of our Probe hardware to withstand the Venus environment. During this testing, we encountered numerous problems, mostly associated with adapting earth-based hardware to operate in the anticipated Venus environment. For example, the Large Probe pressure vessel imploded with a very loud bang the first time we tested its ability to withstand the high pressure and temperature on the Venusian surface. We had to go back and redesign, increasing the pressure vessel wall thickness. In addition, during the first tests of the parachute system, our parachute system ripped apart and had to be redesigned. Finally, at the aptly named test range in Truth or Consequences, New Mexico, we successfully demonstrated the parachute design by drop

  5. Comprehensive automatic assessment of retinal vascular abnormalities for computer-assisted retinopathy grading.

    PubMed

    Joshi, Vinayak; Agurto, Carla; VanNess, Richard; Nemeth, Sheila; Soliz, Peter; Barriga, Simon

    2014-01-01

    One of the most important signs of systemic disease that presents on the retina is vascular abnormalities such as in hypertensive retinopathy. Manual analysis of fundus images by human readers is qualitative and lacks in accuracy, consistency and repeatability. Present semi-automatic methods for vascular evaluation are reported to increase accuracy and reduce reader variability, but require extensive reader interaction; thus limiting the software-aided efficiency. Automation thus holds a twofold promise. First, decrease variability while increasing accuracy, and second, increasing the efficiency. In this paper we propose fully automated software as a second reader system for comprehensive assessment of retinal vasculature; which aids the readers in the quantitative characterization of vessel abnormalities in fundus images. This system provides the reader with objective measures of vascular morphology such as tortuosity, branching angles, as well as highlights of areas with abnormalities such as artery-venous nicking, copper and silver wiring, and retinal emboli; in order for the reader to make a final screening decision. To test the efficacy of our system, we evaluated the change in performance of a newly certified retinal reader when grading a set of 40 color fundus images with and without the assistance of the software. The results demonstrated an improvement in reader's performance with the software assistance, in terms of accuracy of detection of vessel abnormalities, determination of retinopathy, and reading time. This system enables the reader in making computer-assisted vasculature assessment with high accuracy and consistency, at a reduced reading time.

  6. Effect of collagen and elastin content on the burst pressure of human blood vessel seals formed with a bipolar tissue sealing system.

    PubMed

    Latimer, Cassandra A; Nelson, Meghan; Moore, Camille M; Martin, Kimberly E

    2014-01-01

    Bipolar devices are routinely used to seal blood vessels instead of sutures and clips. Recent work examining the impact of vascular proteins on bipolar seal performance found that collagen and elastin (CE) content within porcine arteries was a significant predictor of a vessel's burst pressure (VBPr). This study examined seal performance across a range of human blood vessels to investigate whether a similar relationship existed. In addition, we compared VBPr and CE content between porcine and human blood vessels. Our primary hypothesis is that higher collagen-to-elastin ratio will predict higher VBPr in human vasculature. In six cadavers, 185 blood vessels from nine anatomic locations were sealed using a bipolar electrosurgical system. A linear mixed model framework was used to evaluate the impact of vessel diameter and CE content on VBPr. The effect of CE ratio on VBPr is modified by vessel size, with CE ratio having larger influence on VBPr in smaller diameter vessels. Seal burst pressure of vessels 2-5 mm in diameter was significantly associated with their CE content. Comparison of average VBPr between species revealed porcine carotid and iliac arteries (440-670 mmHg) to be the best vessel types for predicting the seal strength of most human blood vessels (420-570 mmHg) examined. CE content significantly modified the seal strength of small to medium sized blood vessels but had limited impact on vessels >5 mm. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Integral isolation valve systems for loss of coolant accident protection

    DOEpatents

    Kanuch, David J.; DiFilipo, Paul P.

    2018-03-20

    A nuclear reactor includes a nuclear reactor core comprising fissile material disposed in a reactor pressure vessel having vessel penetrations that exclusively carry flow into the nuclear reactor and at least one vessel penetration that carries flow out of the nuclear reactor. An integral isolation valve (IIV) system includes passive IIVs each comprising a check valve built into a forged flange and not including an actuator, and one or more active IIVs each comprising an active valve built into a forged flange and including an actuator. Each vessel penetration exclusively carrying flow into the nuclear reactor is protected by a passive IIV whose forged flange is directly connected to the vessel penetration. Each vessel penetration carrying flow out of the nuclear reactor is protected by an active IIV whose forged flange is directly connected to the vessel penetration. Each active valve may be a normally closed valve.

  8. Condensation induced water hammer driven sterilization

    DOEpatents

    Kullberg, Craig M.

    2004-05-11

    A method and apparatus (10) for treating a fluid or materials therein with acoustic energy has a vessel (14) for receiving the fluid with inner walls shaped to focus acoustic energy to a target zone within the vessel. One or more nozzles (26) are directed into the vessel (14) for injecting a condensable vapor, such as steam, into the vessel (14). The system may include a steam source (18) for providing steam as the condensable vapor from an industrial waste heat source. Steam drums (88) are disposed between the steam source (18) and nozzles (26) to equalize and distribute the vapor pressure. A cooling source (30) provides a secondary fluid for maintaining the liquid in the vessel (14) in subcooled conditions. A heating jacket (32) surrounds the vessel (14) to heat the walls of the vessel (14) and prevent biological growth thereon. A pressurizer (33) may operate the system at elevated pressures.

  9. Electromagnetic diagnostic system for the Keda Torus eXperiment

    NASA Astrophysics Data System (ADS)

    Tu, Cui; Liu, Adi; Li, Zichao; Tan, Mingsheng; Luo, Bing; You, Wei; Li, Chenguang; Bai, Wei; Fu, Chenshuo; Huang, Fangcheng; Xiao, Bingjia; Shen, Biao; Shi, Tonghui; Chen, Dalong; Mao, Wenzhe; Li, Hong; Xie, Jinglin; Lan, Tao; Ding, Weixing; Xiao, Chijin; Liu, Wandong

    2017-09-01

    A system for electromagnetic measurements was designed and installed on the Keda Torus eXperiment (KTX) reversed field pinch device last year. Although the unique double-C structure of the KTX, which allows the machine to be opened easily without disassembling the poloidal field windings, makes the convenient replacement and modification of the internal inductive coils possible, it can present difficulties in the design of flux coils and magnetic probes at the two vertical gaps. Moreover, the KTX has a composite shell consisting of a 6 mm stainless steel vacuum chamber and a 1.5 mm copper shell, which results in limited space for the installation of saddle sensors. Therefore, the double-C structure and composite shell should be considered, especially during the design and installation of the electromagnetic diagnostic system (EDS). The inner surface of the vacuum vessel includes two types of probes. One type is for the measurement of the global plasma parameters, and the other type is for studying the local behavior of the plasma and operating the new saddle coils. In addition, the probes on the outer surface of the composite shell are used for measurements of eddy currents. Finally, saddle sensors for radial field measurements for feedback control were installed between the conducting shell and the vacuum vessel. The entire system includes approximately 1100 magnetic probes, 14 flux coils, 4 ×26 ×2 saddle sensors, and 16 Rogowski coils. Considering the large number of probes and limited space available in the vacuum vessel, the miniaturization of the probes and optimization of the probe distribution are necessary. In addition, accurate calibration and careful mounting of the probes are also required. The frequency response of the designed magnetic probes is up to 200 kHz, and the resolution is 1 G. The EDS, being spherical and of high precision, is one of the most basic and effective diagnostic tools of the KTX and meets the demands imposed by requirements on basic machine operating information and future studies.

  10. 46 CFR 130.120 - Propulsion control.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Propulsion control. 130.120 Section 130.120 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Vessel Control § 130.120 Propulsion control. (a) Each vessel must have— (1...

  11. 46 CFR 130.120 - Propulsion control.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Propulsion control. 130.120 Section 130.120 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Vessel Control § 130.120 Propulsion control. (a) Each vessel must have— (1...

  12. 46 CFR 130.120 - Propulsion control.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Propulsion control. 130.120 Section 130.120 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Vessel Control § 130.120 Propulsion control. (a) Each vessel must have— (1...

  13. 46 CFR 130.120 - Propulsion control.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Propulsion control. 130.120 Section 130.120 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Vessel Control § 130.120 Propulsion control. (a) Each vessel must have— (1...

  14. 46 CFR 130.120 - Propulsion control.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Propulsion control. 130.120 Section 130.120 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Vessel Control § 130.120 Propulsion control. (a) Each vessel must have— (1...

  15. Inflatable Launch and Recovery System

    DTIC Science & Technology

    2014-07-31

    clamping fixture connects the ramp structure to the vessel. A snubber element dampens vibrations and transient tow loads. Unclassified Unclassified...integrated dynamic snubber element to dampen out vibrations and transient tow loads. The main air fill line from the handling system to the inflatable ramp...of the vessel A with standard container cam locks 12a (two of which are shown in phantom in FIG. 1). The system 10 can connect to a vessel power

  16. System and method for determining coolant level and flow velocity in a nuclear reactor

    DOEpatents

    Brisson, Bruce William; Morris, William Guy; Zheng, Danian; Monk, David James; Fang, Biao; Surman, Cheryl Margaret; Anderson, David Deloyd

    2013-09-10

    A boiling water reactor includes a reactor pressure vessel having a feedwater inlet for the introduction of recycled steam condensate and/or makeup coolant into the vessel, and a steam outlet for the discharge of produced steam for appropriate work. A fuel core is located within a lower area of the pressure vessel. The fuel core is surrounded by a core shroud spaced inward from the wall of the pressure vessel to provide an annular downcomer forming a coolant flow path between the vessel wall and the core shroud. A probe system that includes a combination of conductivity/resistivity probes and/or one or more time-domain reflectometer (TDR) probes is at least partially located within the downcomer. The probe system measures the coolant level and flow velocity within the downcomer.

  17. Fractographic study of a thick wall pressure vessel failure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Canonico, D.A.; Crouse, R.S.; Henson, T.J.

    1979-01-01

    The pressure vessel described in this paper is identified as Intermediate Test Vessel 1 (ITV-1) and was fabricated of SA508, Class 2 Steel. It was tested to failure at 54/sup 0/C (130/sup 0/F). The gross failure appeared to be a brittle fracture although accompanied by a measured strain of 0.9%. Seven regions of the fracture were examined in detail and the observed surfaces were compared to Charpy V-notch (C/sub v/) specimens of SA508, Class 2 steel broken at temperatures above and below the ductile to brittle transition temperature. Three samples from the vessel were taken in the region around themore » fatigue notch and four from areas well removed from the notch. All these were carefully examined both optically and by scanning electron microscopy (SEM). It was established that early crack extension was by ductile mode until a large flaw approximately 500 mm long 83 mm wide was developed. At this point the vessel could no longer contain the internal pressure and final rupture was by brittle fracture.« less

  18. Polymethylmethacrylate (PMMA) Material Test Results for the Capillary Flow Experiments (CFE)

    NASA Technical Reports Server (NTRS)

    Lerch, Bradley A.; Thesken, John C.; Bunnell, Charles T.

    2007-01-01

    In support of the Capillary Flow Experiments (CFE) program, several polymethylmethacrylate (PMMA) flight vessels were constructed. Some vessels used a multipiece design, which was chemically welded together. Due to questions regarding the effects of the experiment fluid (silicone oil) on the weld integrity, a series of tests were conducted to provide evidence of the adequacy of the current vessel design. Tensile tests were conducted on PMMA samples that were both in the as-received condition, and also aged in air or oil for up to 8 weeks. Both welded and unwelded samples were examined. Fracture of the joints was studied using notched tensile specimens and Brazilian disk tests. Results showed that aging had no effect on tensile properties. While the welded samples were weaker than the base parent material, the weld strength was found to be further degraded by bubbles in the weld zone. Finally a fracture analysis using the worst-case fracture conditions of the vessel was performed, and the vessel design was found to have a factor of three safety margin.

  19. 46 CFR 111.105-39 - Additional requirements for vessels carrying vehicles with fuel in their tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Additional requirements for vessels carrying vehicles... SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-39 Additional requirements for vessels carrying vehicles with fuel in their tanks. Each vessel...

  20. 46 CFR 111.105-39 - Additional requirements for vessels carrying vehicles with fuel in their tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Additional requirements for vessels carrying vehicles... SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-39 Additional requirements for vessels carrying vehicles with fuel in their tanks. Each vessel...

  1. 46 CFR 111.105-45 - Vessels carrying agricultural products.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...

  2. 46 CFR 111.105-45 - Vessels carrying agricultural products.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...

  3. 46 CFR 111.105-45 - Vessels carrying agricultural products.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...

  4. 46 CFR 111.105-45 - Vessels carrying agricultural products.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...

  5. 46 CFR 111.105-45 - Vessels carrying agricultural products.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...

  6. 46 CFR 195.30-90 - Vessels contracted for before November 23, 1992.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Vessels contracted for before November 23, 1992. 195.30-90 Section 195.30-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195...

  7. 46 CFR 195.30-90 - Vessels contracted for before November 23, 1992.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Vessels contracted for before November 23, 1992. 195.30-90 Section 195.30-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195...

  8. 33 CFR 104.405 - Format of the Vessel Security Plan (VSP).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Communications; (9) Security systems and equipment maintenance; (10) Security measures for access control... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Format of the Vessel Security... SECURITY MARITIME SECURITY MARITIME SECURITY: VESSELS Vessel Security Plan (VSP) § 104.405 Format of the...

  9. 48 CFR 52.247-37 - F.o.b. Vessel, Port of Shipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false F.o.b. Vessel, Port of....247-37 F.o.b. Vessel, Port of Shipment. As prescribed in 47.303-9(c), insert the following clause in solicitations and contracts when the delivery term is f.o.b. vessel, port of shipment: F.o.b. Vessel, Port of...

  10. Application of a newly built semi-submersible vessel for transportation of a tension leg platform

    NASA Astrophysics Data System (ADS)

    Zhang, Dagang; Sun, Weiying; Fan, Zhixia

    2012-09-01

    Transportation of tension leg platform (TLP) structures for a long distance has always been associated with the use of a heavy semi-transport vessel. The requirements of this type of vessel are always special, and their availability is limited. To prepare for the future development of South China Sea deepwater projects, the China Offshore Oil Engineering Corporation has recently built a heavy lift transport vessel-Hai Yang Shi You 278. This semi-submersible vessel has a displacement capacity of 50k DWT, and a breath of 42 meters. Understanding the vessel's applicability and preparing it for use in future deepwater projects are becoming imminent needs. This paper reviews the current critical issues associated with TLP transportation and performs detailed analysis of the designed TLP during load-out and transportation. The newly built COOEC transportation vessel HYSY 278 was applied to dry transport of the TLP structure from the COOEC fabrication yard in Qingdao to an oil field in South China Sea. The entire process included the load-out of the TLP structure from the landsite of the fabrication yard, the offloading and float-on of the platform from the vessel, the dry transport of the TLP over a long distance, and the final offloading of the platform. Both hydrodynamic and structure analysis were performed to evaluate the behavior of the transport vessel and TLP structure. Special attention was paid to critical areas associated with the use of this new vessel, along with any potential limitations. The results demonstrate that HYSY 278 can effectively be used for transporting the structure with proper arrangement and well-prepared operation. The procedure and details were presented on the basis of the study results. Special attention was also given to discussion on future use based on the results from the analysis.

  11. 78 FR 73726 - Endangered Fish and Wildlife; Final Rule To Remove the Sunset Provision of the Final Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-09

    ... expanded speed/risk models, one study estimated that the 2008 vessel speed rule reduced the risk of lethal... are completely absent there or that the risk of strikes does not exist. One recent study concluded... the world's most critically endangered large whale species and one of the world's most endangered...

  12. 46 CFR 130.440 - Communications system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Communications system. 130.440 Section 130.440 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.440 Communications system...

  13. Performance of a water suction system using hydrophilic fibrous cloth under low gravity and microgravity in parabolic flight.

    PubMed

    Tani, A; Saito, T; Kitaya, Y; Takahashi, H; Goto, E

    2000-06-01

    For suction of water from a water supply vessel including both water and air under microgravity and g-jitter conditions, a water suction system using hydrophilic fibrous cloth was developed and its performance was evaluated at 0.01-0.02 g-realized for 20 s by parabolic flight in an aircraft. Vessels used for the experiment were glass flasks and had a suction port for suction filtration. A piece of hydrophilic fibrous cloth was arranged along the inner surface of the vessels and the end was fixed to the suction port of the vessels. In vessel without hydrophilic cloths and containing 220 mL of water, the water did not move more than 5 mm along the inner surface and did not reach the suction port under low gravity. When hydrophilic cloths were used, on the other hand, water gathered onto the cloth surface, moved up along the cloth and reached the suction port under low gravity. The amount of water sucked from vessels varied with the amount of water in the vessel and the sectional area of hydrophilic cloths. When the vessels including both water and air were flown during parabolic flight (10(-4) g), water in the vessel moved along the cloth and a water film was formed on the cloth. These results indicated that it is possible to suck water using the fibrous cloth suction system under low gravity and microgravity conditions. Under low gravity conditions, it was difficult to suck water only. However, it is not necessary to separate water from air when the system is used for supplying water to plant root medium consisting of both liquid and gas phases.

  14. Neonatal systemic inflammation in rats alters retinal vessel development and simulates pathologic features of retinopathy of prematurity.

    PubMed

    Hong, Hye Kyoung; Lee, Hyun Ju; Ko, Jung Hwa; Park, Ji Hyun; Park, Ji Yeon; Choi, Chang Won; Yoon, Chang-Hwan; Ahn, Seong Joon; Park, Kyu Hyung; Woo, Se Joon; Oh, Joo Youn

    2014-05-15

    Alteration of retinal angiogenesis during development leads to retinopathy of prematurity (ROP) in preterm infants, which is a leading cause of visual impairment in children. A number of clinical studies have reported higher rates of ROP in infants who had perinatal infections or inflammation, suggesting that exposure of the developing retina to inflammation may disturb retinal vessel development. Thus, we investigated the effects of systemic inflammation on retinal vessel development and retinal inflammation in neonatal rats. To induce systemic inflammation, we intraperitoneally injected 100 μl lipopolysaccharide (LPS, 0.25 mg/ml) or the same volume of normal saline in rat pups on postnatal days 1, 3, and 5. The retinas were extracted on postnatal days 7 and 14, and subjected to assays for retinal vessels, inflammatory cells and molecules, and apoptosis. We found that intraperitoneal injection of LPS impaired retinal vessel development by decreasing vessel extension, reducing capillary density, and inducing localized overgrowth of abnormal retinal vessels and dilated peripheral vascular ridge, all of which are characteristic findings of ROP. Also, a large number of CD11c+ inflammatory cells and astrocytes were localized in the lesion of abnormal vessels. Further analysis revealed that the number of major histocompatibility complex (MHC) class IIloCD68loCD11bloCD11chi cells in the retina was higher in LPS-treated rats compared to controls. Similarly, the levels of TNF-α, IL-1β, and IL-12a were increased in LPS-treated retina. Also, apoptosis was increased in the inner retinal layer where retinal vessels are located. Our data demonstrate that systemic LPS-induced inflammation elicits retinal inflammation and impairs retinal angiogenesis in neonatal rats, implicating perinatal inflammation in the pathogenesis of ROP.

  15. Reactor water cleanup system

    DOEpatents

    Gluntz, Douglas M.; Taft, William E.

    1994-01-01

    A reactor water cleanup system includes a reactor pressure vessel containing a reactor core submerged in reactor water. First and second parallel cleanup trains are provided for extracting portions of the reactor water from the pressure vessel, cleaning the extracted water, and returning the cleaned water to the pressure vessel. Each of the cleanup trains includes a heat exchanger for cooling the reactor water, and a cleaner for cleaning the cooled reactor water. A return line is disposed between the cleaner and the pressure vessel for channeling the cleaned water thereto in a first mode of operation. A portion of the cooled water is bypassed around the cleaner during a second mode of operation and returned through the pressure vessel for shutdown cooling.

  16. Captopril improves tumor nanomedicine delivery by increasing tumor blood perfusion and enlarging endothelial gaps in tumor blood vessels.

    PubMed

    Zhang, Bo; Jiang, Ting; Tuo, Yanyan; Jin, Kai; Luo, Zimiao; Shi, Wei; Mei, Heng; Hu, Yu; Pang, Zhiqing; Jiang, Xinguo

    2017-12-01

    Poor tumor perfusion and unfavorable vessel permeability compromise nanomedicine drug delivery to tumors. Captopril dilates blood vessels, reducing blood pressure clinically and bradykinin, as the downstream signaling moiety of captopril, is capable of dilating blood vessels and effectively increasing vessel permeability. The hypothesis behind this study was that captopril can dilate tumor blood vessels, improving tumor perfusion and simultaneously enlarge the endothelial gaps of tumor vessels, therefore enhancing nanomedicine drug delivery for tumor therapy. Using the U87 tumor xenograft with abundant blood vessels as the tumor model, tumor perfusion experiments were carried out using laser Doppler imaging and lectin-labeling experiments. A single treatment of captopril at a dose of 100 mg/kg significantly increased the percentage of functional vessels in tumor tissues and improved tumor blood perfusion. Scanning electron microscopy of tumor vessels also indicated that the endothelial gaps of tumor vessels were enlarged after captopril treatment. Immunofluorescence-staining of tumor slices demonstrated that captopril significantly increased bradykinin expression, possibly explaining tumor perfusion improvements and endothelial gap enlargement. Additionally, imaging in vivo, imaging ex vivo and nanoparticle distribution in tumor slices indicated that after a single treatment with captopril, the accumulation of 115-nm nanoparticles in tumors had increased 2.81-fold with a more homogeneous distribution pattern in comparison to non-captopril treated controls. Finally, pharmacodynamics experiments demonstrated that captopril combined with paclitaxel-loaded nanoparticles resulted in the greatest tumor shrinkage and the most extensive necrosis in tumor tissues among all treatment groups. Taken together, the data from the present study suggest a novel strategy for improving tumor perfusion and enlarging blood vessel permeability simultaneously in order to improve nanomedicine delivery for tumor therapy. As captopril has already been extensively used clinically, such a strategy has great therapeutic potential. Copyright © 2017. Published by Elsevier B.V.

  17. Blood vessel rupture by cavitation

    PubMed Central

    Chen, Hong; Brayman, Andrew A.; Bailey, Michael R.

    2011-01-01

    Cavitation is thought to be one mechanism for vessel rupture during shock wave lithotripsy treatment. However, just how cavitation induces vessel rupture remains unknown. In this work, a high-speed photomicrography system was set up to directly observe the dynamics of bubbles inside blood vessels in ex vivo rat mesenteries. Vascular rupture correlating to observed bubble dynamics were examined by imaging bubble extravasation and dye leakage. The high-speed images show that bubble expansion can cause vessel distention, and bubble collapse can lead to vessel invagination. Liquid jets were also observed to form. Our results suggest that all three mechanisms, vessel distention, invagination and liquid jets, can contribute to vessel rupture. PMID:20680255

  18. 46 CFR 176.615 - Underwater Survey in Lieu of Drydocking (UWILD).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 15 years of age; (2) A steel or aluminum hulled vessel; (3) Fitted with an effective hull protection system; and (4) Described in § 176.600(b) or (c) of this part. (b) For vessels less than 15 years of age... protection system; and (7) The name and qualifications of any third party examiner. (c) If your vessel is 15...

  19. 33 CFR 157.43 - Discharges of clean and segregated ballast: Seagoing tank vessels of 150 gross tons or more.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...

  20. 33 CFR 157.43 - Discharges of clean and segregated ballast: Seagoing tank vessels of 150 gross tons or more.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...

  1. 33 CFR 157.43 - Discharges of clean and segregated ballast: Seagoing tank vessels of 150 gross tons or more.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...

  2. 33 CFR 157.43 - Discharges of clean and segregated ballast: Seagoing tank vessels of 150 gross tons or more.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...

  3. 33 CFR 157.43 - Discharges of clean and segregated ballast: Seagoing tank vessels of 150 gross tons or more.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...

  4. Biomass Economy

    DTIC Science & Technology

    1985-11-01

    Boiler and Pressure Vessel Code HEI Heat Exchanger Institute Heat and Material Balance c. System Description (1) Condenser... Boiler and Pressure Vessel Code "AN(SI B31.1 Power Piping d. System Description (1) Deaerator The deaerator will be d direct contact feedwater heater, and...vent, and drain piping. "b . Applicable Codes ASME Boiler and Pressure Vessel Code "ANSI B31.1 - Power Piping Code

  5. Reactor vessel support system. [LMFBR

    DOEpatents

    Golden, M.P.; Holley, J.C.

    1980-05-09

    A reactor vessel support system includes a support ring at the reactor top supported through a box ring on a ledge of the reactor containment. The box ring includes an annular space in the center of its cross-section to reduce heat flow and is keyed to the support ledge to transmit seismic forces from the reactor vessel to the containment structure. A coolant channel is provided at the outside circumference of the support ring to supply coolant gas through the keyways to channels between the reactor vessel and support ledge into the containment space.

  6. RAPID COMMUNICATION: Magnetic resonance imaging inside metallic vessels

    NASA Astrophysics Data System (ADS)

    Han, Hui; Balcom, Bruce J.

    2010-10-01

    We introduce magnetic resonance imaging (MRI) measurements inside metallic vessels. Until now, MRI has been unusable inside metallic vessels because of eddy currents in the walls. We have solved the problem and generated high quality images by employing a magnetic field gradient monitoring method. The ability to image within metal enclosures and structures means many new samples and systems are now amenable to MRI. Most importantly this study will form the basis of new MRI-compatible metallic pressure vessels, which will permit MRI of macroscopic systems at high pressure.

  7. 46 CFR 119.510 - Bilge piping system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Bilge piping system. 119.510 Section 119.510 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Ballast Systems § 119.510 Bilge piping system. A vessel must be provided with a piping system that meets...

  8. 46 CFR 119.510 - Bilge piping system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Bilge piping system. 119.510 Section 119.510 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Ballast Systems § 119.510 Bilge piping system. A vessel must be provided with a piping system that meets...

  9. Motion correction for passive radiation imaging of small vessels in ship-to-ship inspections

    NASA Astrophysics Data System (ADS)

    Ziock, K. P.; Boehnen, C. B.; Ernst, J. M.; Fabris, L.; Hayward, J. P.; Karnowski, T. P.; Paquit, V. C.; Patlolla, D. R.; Trombino, D. G.

    2016-01-01

    Passive radiation detection remains one of the most acceptable means of ascertaining the presence of illicit nuclear materials. In maritime applications it is most effective against small to moderately sized vessels, where attenuation in the target vessel is of less concern. Unfortunately, imaging methods that can remove source confusion, localize a source, and avoid other systematic detection issues cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing system sensitivity. This is particularly true for the smaller watercraft, where passive inspections are most valuable. We have developed a combined gamma-ray, stereo visible-light imaging system that addresses this problem. Data from the stereo imager are used to track the relative location and orientation of the target vessel in the field of view of a coded-aperture gamma-ray imager. Using this information, short-exposure gamma-ray images are projected onto the target vessel using simple tomographic back-projection techniques, revealing the location of any sources within the target. The complex autonomous tracking and image reconstruction system runs in real time on a 48-core workstation that deploys with the system.

  10. Motion correction for passive radiation imaging of small vessels in ship-to-ship inspections

    DOE PAGES

    Ziock, Klaus -Peter; Boehnen, Chris Bensing; Ernst, Joseph M.; ...

    2015-09-05

    Passive radiation detection remains one of the most acceptable means of ascertaining the presence of illicit nuclear materials. In maritime applications it is most effective against small to moderately sized vessels, where attenuation in the target vessel is of less concern. Unfortunately, imaging methods that can remove source confusion, localize a source, and avoid other systematic detection issues cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing system sensitivity. This is particularly true for the smaller watercraft, where passive inspections are most valuable. We have developed a combinedmore » gamma-ray, stereo visible-light imaging system that addresses this problem. Data from the stereo imager are used to track the relative location and orientation of the target vessel in the field of view of a coded-aperture gamma-ray imager. Using this information, short-exposure gamma-ray images are projected onto the target vessel using simple tomographic back-projection techniques, revealing the location of any sources within the target. Here,the complex autonomous tracking and image reconstruction system runs in real time on a 48-core workstation that deploys with the system.« less

  11. Vessel-Mounted ADCP Data Calibration and Correction

    NASA Astrophysics Data System (ADS)

    de Andrade, A. F.; Barreira, L. M.; Violante-Carvalho, N.

    2013-05-01

    A set of scripts for vessel-mounted ADCP (Acoustic Doppler Current Profiler) data processing is presented. The need for corrections in the data measured by a ship-mounted ADCP and the complexities found during installation, implementation and identification of tasks performed by currently available systems for data processing consist the main motivating factors for the development of a system that would be more practical in manipulation, open code and more manageable for the user. The proposed processing system consists of a set of scripts developed in Matlab TM programming language. The system is able to read the binary files provided by the data acquisition program VMDAS (Vessel Mounted Data Acquisition System), Teledyne RDInstruments proprietary, and calculate calibration factors to correct the data and visualize them after correction. For use the new system, it is only necessary that the ADCP data collected with VMDAS program is in a processing diretory and Matlab TM software be installed on the user's computer. Developed algorithms were extensively tested with ADCP data obtained during Oceano Sul III (Southern Ocean III - OSIII) cruise, conducted by Brazilian Navy aboard the R/V "Antares", from March 26th to May 10th 2007, in the oceanic region between the states of São Paulo and Rio Grande do Sul. For read the data the function rdradcp.m, developed by Rich Pawlowicz and available on his website (http://www.eos.ubc.ca/~rich/#RDADCP), was used. To calculate the calibration factors, alignment error (α) and sensitivity error (β) in Water Tracking and Bottom Tracking Modes, equations deduced by Joyce (1998), Pollard & Read (1989) and Trump & Marmorino (1996) were implemented in Matlab. To validate the calibration factors obtained in the processing system developed, the parameters were compared with the factors provided by CODAS (Common Ocean Data Access System, available at http://currents.soest.hawaii.edu/docs/doc/index.html), post-processing program. For the same data analyzed, the factors provided by both systems were similar. Thereafter, the values obtained were used to correct the data and finally matrices were saved with data corrected and they can be plotted. The values of volume transport of the Brazil Current (BC) were calculated using the corrected data by the two systems and proved quite close, confirming the quality of the correction of the system.

  12. Lymphatic drainage system of the brain: A novel target for intervention of neurological diseases.

    PubMed

    Sun, Bao-Liang; Wang, Li-Hua; Yang, Tuo; Sun, Jing-Yi; Mao, Lei-Lei; Yang, Ming-Feng; Yuan, Hui; Colvin, Robert A; Yang, Xiao-Yi

    2017-09-10

    The belief that the vertebrate brain functions normally without classical lymphatic drainage vessels has been held for many decades. On the contrary, new findings show that functional lymphatic drainage does exist in the brain. The brain lymphatic drainage system is composed of basement membrane-based perivascular pathway, a brain-wide glymphatic pathway, and cerebrospinal fluid (CSF) drainage routes including sinus-associated meningeal lymphatic vessels and olfactory/cervical lymphatic routes. The brain lymphatic systems function physiological as a route of drainage for interstitial fluid (ISF) from brain parenchyma to nearby lymph nodes. Brain lymphatic drainage helps maintain water and ion balance of the ISF, waste clearance, and reabsorption of macromolecular solutes. A second physiological function includes communication with the immune system modulating immune surveillance and responses of the brain. These physiological functions are influenced by aging, genetic phenotypes, sleep-wake cycle, and body posture. The impairment and dysfunction of the brain lymphatic system has crucial roles in age-related changes of brain function and the pathogenesis of neurovascular, neurodegenerative, and neuroinflammatory diseases, as well as brain injury and tumors. In this review, we summarize the key component elements (regions, cells, and water transporters) of the brain lymphatic system and their regulators as potential therapeutic targets in the treatment of neurologic diseases and their resulting complications. Finally, we highlight the clinical importance of ependymal route-based targeted gene therapy and intranasal drug administration in the brain by taking advantage of the unique role played by brain lymphatic pathways in the regulation of CSF flow and ISF/CSF exchange. Copyright © 2017. Published by Elsevier Ltd.

  13. Passive cooling safety system for liquid metal cooled nuclear reactors

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.; Hui, Marvin M.; Berglund, Robert C.

    1991-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel. The passive cooling system includes a closed primary fluid circuit through the partitions surrounding the reactor vessel and a partially adjoining secondary open fluid circuit for carrying transferred heat out into the atmosphere.

  14. Indirect passive cooling system for liquid metal cooled nuclear reactors

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.

    1990-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel. The passive cooling system includes a closed primary fluid circuit through the partitions surrounding the reactor vessel and a partially adjoining secondary open fluid circuit for carrying transferred heat out into the atmosphere.

  15. Direct Final Rule for Technical Amendments for Marine Spark-Ignition Engines and Vessels

    EPA Pesticide Factsheets

    Rule published September 16, 2010 to make technical amendments to the design standard for portable marine fuel tanks. This rule incorporates safe recommended practices, developed through industry consensus.

  16. 75 FR 68467 - Transportation for Individuals With Disabilities: Passenger Vessels

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-08

    ... (PSAs). They supported considering such animals to be service animals and opposed permitting emotional... of service animals encompasses PSAs. The preamble to the final rule made clear that ESAs, consistent...

  17. [Large vessels vasculopathy in systemic sclerosis].

    PubMed

    Tejera Segura, Beatriz; Ferraz-Amaro, Iván

    2015-12-07

    Vasculopathy in systemic sclerosis is a severe, in many cases irreversible, manifestation that can lead to amputation. While the classical clinical manifestations of the disease have to do with the involvement of microcirculation, proximal vessels of upper and lower limbs can also be affected. This involvement of large vessels may be related to systemic sclerosis, vasculitis or atherosclerotic, and the differential diagnosis is not easy. To conduct a proper and early diagnosis, it is essential to start prompt appropriate treatment. In this review, we examine the involvement of large vessels in scleroderma, an understudied manifestation with important prognostic and therapeutic implications. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  18. 46 CFR 31.35-5 - Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... OF HOMELAND SECURITY TANK VESSELS INSPECTION AND CERTIFICATION Electrical Engineering § 31.35-5... vessels are subject to the regulations contained in subchapter J (Electrical Engineering) of this chapter...

  19. 46 CFR 31.35-5 - Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF HOMELAND SECURITY TANK VESSELS INSPECTION AND CERTIFICATION Electrical Engineering § 31.35-5... vessels are subject to the regulations contained in subchapter J (Electrical Engineering) of this chapter...

  20. 46 CFR 31.35-5 - Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF HOMELAND SECURITY TANK VESSELS INSPECTION AND CERTIFICATION Electrical Engineering § 31.35-5... vessels are subject to the regulations contained in subchapter J (Electrical Engineering) of this chapter...

  1. 46 CFR 195.05-1 - Installation and details.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS VESSEL... of this type include the following: Ship's Service Generating Systems. Ship's Service Power... Lighting and Power Systems. Electric Lifeboat Winch Systems. Electric Steering Gear and Steering Control...

  2. 46 CFR 298.11 - Vessel requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... with accepted commercial experience and practice. (g) Metric Usage. Our preferred system of measurement and weights for Vessels and Shipyard Projects is the metric system. ...), classification societies to be ISO 9000 series registered or Quality Systems Certificate Scheme qualified IACS...

  3. 46 CFR 298.11 - Vessel requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... with accepted commercial experience and practice. (g) Metric Usage. Our preferred system of measurement and weights for Vessels and Shipyard Projects is the metric system. ...), classification societies to be ISO 9000 series registered or Quality Systems Certificate Scheme qualified IACS...

  4. 46 CFR 298.11 - Vessel requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... with accepted commercial experience and practice. (g) Metric Usage. Our preferred system of measurement and weights for Vessels and Shipyard Projects is the metric system. ...), classification societies to be ISO 9000 series registered or Quality Systems Certificate Scheme qualified IACS...

  5. 46 CFR 298.11 - Vessel requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... with accepted commercial experience and practice. (g) Metric Usage. Our preferred system of measurement and weights for Vessels and Shipyard Projects is the metric system. ...), classification societies to be ISO 9000 series registered or Quality Systems Certificate Scheme qualified IACS...

  6. 46 CFR 298.11 - Vessel requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... with accepted commercial experience and practice. (g) Metric Usage. Our preferred system of measurement and weights for Vessels and Shipyard Projects is the metric system. ...), classification societies to be ISO 9000 series registered or Quality Systems Certificate Scheme qualified IACS...

  7. Electrical insulation system for the shell-vacuum vessel and poloidal field gap in the ZTH machine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reass, W.A.; Ballard, E.O.

    1989-01-01

    The electrical insulation systems for the ZTH machine have many unusual design problems. The poloidal field gap insulation must be capable of conforming to poloidal and toroidal contours, provide a 25 kV hold off, and sufficiently adhere to the epoxy back fill between the overlapping conductors. The shell-vacuum vessel system will use stretchable and flexible insulation along with protective hats, boots and sleeves. The shell-vacuum vessel system must be able to withstand a 12.5 kV pulse with provision for thermal insulation to limit the effects of the 300{degrees}C vacuum vessel during operation and bakeout. Methodology required to provide the electricalmore » protection along with testing data and material characteristics will be presented. 7 figs.« less

  8. Power recovery system for coal liquefaction process

    DOEpatents

    Horton, Joel R.

    1985-01-01

    Method and apparatus for minimizing energy required to inject reactant such as coal-oil slurry into a reaction vessel, using high pressure effluent from the latter to displace the reactant from a containment vessel into the reaction vessel with assistance of low pressure pump. Effluent is degassed in the containment vessel, and a heel of the degassed effluent is maintained between incoming effluent and reactant in the containment vessel.

  9. Evaluation of three composting systems for the management of spent coffee grounds.

    PubMed

    Liu, K; Price, G W

    2011-09-01

    This study was conducted to evaluate the optimum composting approach for the management of spent coffee grounds from the restaurant and ready-to-serve coffee industry. Three composting systems were assessed, including in-vessel composting, vermicomposting bins, and aerated static pile bin composting, over study periods ranging from 47 to 98 days. Total carbon content was reduced by 5-7% in the spent coffee ground treatments across the three composting systems. Nitrogen and other mineral nutrient contents were conserved or enhanced from the initial to the final composts in all the composting systems assessed. Earthworm growth and survival (15-80%) was reduced in all the treatments but mortality rates were lower in coffee treatments with cardboard additions. A decline in earthworm mortality with cardboard additions was the result of reduced exposure to organic compounds and chemicals released through the decomposition of spent coffee grounds. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Myopathy in a patient with systemic AA amyloidosis possibly induced by psoriasis vulgaris: An autopsy case.

    PubMed

    Tanabe, Hajime; Maki, Yoshimitsu; Urabe, Shogo; Higuchi, Itsuro; Obayashi, Konen; Hokezu, Youichi

    2015-12-01

    Amyloid myopathy is a rare manifestation of primary systemic amyloid light-chain (AL) amyloidosis, but it has not been reported to occur in secondary amyloid A (AA) amyloidosis. We describe a 46-year-old man with psoriasis vulgaris who presented with idiopathic upper and lower limb weakness and was eventually diagnosed with hypertrophic cardiomyopathy. Muscle biopsy findings were compatible with mild inflammatory myopathy. He died of cardiopulmonary arrest, and an autopsy was performed. The autopsy revealed amyloid plaques immunopositive for AA (but not AL or transthyretin) in the perimysial, perivascular, and endomysial regions of the iliopsoas muscle. The final diagnosis was systemic AA amyloidosis with muscle amyloid angiopathy, possibly induced by psoriasis vulgaris. This is an extremely rare autopsy case of myopathy in a patient with systemic AA amyloidosis. The reason for the unusually large amount of amyloid deposition in muscle blood vessel walls remains unclear. © 2015 Wiley Periodicals, Inc.

  11. 50 CFR 660.14 - Vessel Monitoring System (VMS) requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... transmissions to NMFS OLE prior to fishing: (1) Any vessel registered for use with a limited entry “A” endorsed... vessel re-enters the EEZ off the coasts of Washington, Oregon or California. Under this exemption, the... approved for this exemption. (iii) Permit exemption. If the limited entry permit had a change in vessel...

  12. 50 CFR 660.14 - Vessel Monitoring System (VMS) requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... transmissions to NMFS OLE prior to fishing: (1) Any vessel registered for use with a limited entry “A” endorsed... vessel re-enters the EEZ off the coasts of Washington, Oregon or California. Under this exemption, the... approved for this exemption. (iii) Permit exemption. If the limited entry permit had a change in vessel...

  13. 46 CFR 96.30-90 - Vessels contracted for before November 23, 1992.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Vessels contracted for before November 23, 1992. 96.30-90 Section 96.30-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 96...

  14. 46 CFR 96.30-90 - Vessels contracted for before November 23, 1992.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Vessels contracted for before November 23, 1992. 96.30-90 Section 96.30-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 96...

  15. 36 CFR 13.1152 - Private vessel permits and conditions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay National Park and Preserve Vessel Permits § 13.1152 Private vessel permits and conditions. In Glacier Bay from June 1 through... period of time. (a) From June 1 through August 31, when the operator of a private vessel enters Glacier...

  16. 36 CFR 13.1152 - Private vessel permits and conditions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay National Park and Preserve Vessel Permits § 13.1152 Private vessel permits and conditions. In Glacier Bay from June 1 through... period of time. (a) From June 1 through August 31, when the operator of a private vessel enters Glacier...

  17. 36 CFR 13.1152 - Private vessel permits and conditions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay National Park and Preserve Vessel Permits § 13.1152 Private vessel permits and conditions. In Glacier Bay from June 1 through... period of time. (a) From June 1 through August 31, when the operator of a private vessel enters Glacier...

  18. Translational neurocardiology: preclinical models and cardioneural integrative aspects.

    PubMed

    Ardell, J L; Andresen, M C; Armour, J A; Billman, G E; Chen, P-S; Foreman, R D; Herring, N; O'Leary, D S; Sabbah, H N; Schultz, H D; Sunagawa, K; Zucker, I H

    2016-07-15

    Neuronal elements distributed throughout the cardiac nervous system, from the level of the insular cortex to the intrinsic cardiac nervous system, are in constant communication with one another to ensure that cardiac output matches the dynamic process of regional blood flow demand. Neural elements in their various 'levels' become differentially recruited in the transduction of sensory inputs arising from the heart, major vessels, other visceral organs and somatic structures to optimize neuronal coordination of regional cardiac function. This White Paper will review the relevant aspects of the structural and functional organization for autonomic control of the heart in normal conditions, how these systems remodel/adapt during cardiac disease, and finally how such knowledge can be leveraged in the evolving realm of autonomic regulation therapy for cardiac therapeutics. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  19. Start-up control system and vessel for LMFBR

    DOEpatents

    Durrant, Oliver W.; Kakarala, Chandrasekhara R.; Mandel, Sheldon W.

    1987-01-01

    A reflux condensing start-up system includes a steam generator, a start-up vessel connected parallel to the steam generator, a main steam line connecting steam outlets of the steam generator and start-up vessel to a steam turbine, a condenser connected to an outlet of the turbine and a feedwater return line connected between the condenser and inlets of the steam generator and start-up vessel. The start-up vessel has one or more heaters at the bottom thereof for heating feedwater which is supplied over a start-up line to the start-up vessel. Steam is thus generated to pressurize the steam generator before the steam generator is supplied with a heat transfer medium, for example liquid sodium, in the case of a liquid metal fast breeder reactor. The start-up vessel includes upper and lower bulbs with a smaller diameter mid-section to act as water and steam reservoirs. The start-up vessel can thus be used not only in a start-up operation but as a mixing tank, a water storage tank and a level control at low loads for controlling feedwater flow.

  20. Start-up control system and vessel for LMFBR

    DOEpatents

    Durrant, Oliver W.; Kakarala, Chandrasekhara R.; Mandel, Sheldon W.

    1987-01-01

    A reflux condensing start-up system comprises a steam generator, a start-up vessel connected parallel to the steam generator, a main steam line connecting steam outlets of the steam generator and start-up vessel to a steam turbine, a condenser connected to an outlet of the turbine and a feedwater return line connected between the condenser and inlets of the steam generator and start-up vessel. The start-up vessel has one or more heaters at the bottom thereof for heating feedwater which is supplied over a start-up line to the start-up vessel. Steam is thus generated to pressurize the steam generator before the steam generator is supplied with a heat transfer medium, for example liquid sodium, in the case of a liquid metal fast breeder reactor. The start-up vessel includes upper and lower bulbs with a smaller diameter mid-section to act as water and steam reservoirs. The start-up vessel can thus be used not only in a start-up operation but as a mixing tank, a water storage tank and a level control at low loads for controlling feedwater flow.

  1. Ion transport membrane module and vessel system

    DOEpatents

    Stein, VanEric Edward; Carolan, Michael Francis; Chen, Christopher M.; Armstrong, Phillip Andrew; Wahle, Harold W.; Ohrn, Theodore R.; Kneidel, Kurt E.; Rackers, Keith Gerard; Blake, James Erik; Nataraj, Shankar; van Doorn, Rene Hendrik Elias; Wilson, Merrill Anderson

    2007-02-20

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an exterior, an inlet, and an outlet; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region, wherein any inlet and any outlet of the pressure vessel are in flow communication with exterior regions of the membrane modules; and (c) one or more gas manifolds in flow communication with interior regions of the membrane modules and with the exterior of the pressure vessel. The ion transport membrane system may be utilized in a gas separation device to recover oxygen from an oxygen-containing gas or as an oxidation reactor to oxidize compounds in a feed gas stream by oxygen permeated through the mixed metal oxide ceramic material of the membrane modules.

  2. Passive containment cooling system

    DOEpatents

    Billig, P.F.; Cooke, F.E.; Fitch, J.R.

    1994-01-25

    A passive containment cooling system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel and is vented to the drywell. An isolation pool is disposed above the GDCS pool and includes an isolation condenser therein. The condenser has an inlet line disposed in flow communication with the drywell for receiving the non-condensable gas along with any steam released therein following a loss-of-coolant accident (LOCA). The condenser also has an outlet line disposed in flow communication with the drywell for returning to the drywell both liquid condensate produced upon cooling of the steam and the non-condensable gas for reducing pressure within the containment vessel following the LOCA. 1 figure.

  3. Passive containment cooling system

    DOEpatents

    Billig, Paul F.; Cooke, Franklin E.; Fitch, James R.

    1994-01-01

    A passive containment cooling system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel and is vented to the drywell. An isolation pool is disposed above the GDCS pool and includes an isolation condenser therein. The condenser has an inlet line disposed in flow communication with the drywell for receiving the non-condensable gas along with any steam released therein following a loss-of-coolant accident (LOCA). The condenser also has an outlet line disposed in flow communication with the drywell for returning to the drywell both liquid condensate produced upon cooling of the steam and the non-condensable gas for reducing pressure within the containment vessel following the LOCA.

  4. Pressure suppression containment system

    DOEpatents

    Gluntz, Douglas M.; Townsend, Harold E.

    1994-03-15

    A pressure suppression containment system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel. The wetwell pool includes a plenum for receiving the non-condensable gas carried with steam from the drywell following a loss-of coolant-accident (LOCA). The wetwell plenum is vented to a plenum above the GDCS pool following the LOCA for suppressing pressure rise within the containment vessel. A method of operation includes channeling steam released into the drywell following the LOCA into the wetwell pool for cooling along with the non-condensable gas carried therewith. The GDCS pool is then drained by gravity, and the wetwell plenum is vented into the GDCS plenum for channeling the non-condensable gas thereto.

  5. Pressure suppression containment system

    DOEpatents

    Gluntz, D.M.; Townsend, H.E.

    1994-03-15

    A pressure suppression containment system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel. The wetwell pool includes a plenum for receiving the non-condensable gas carried with steam from the drywell following a loss-of-coolant-accident (LOCA). The wetwell plenum is vented to a plenum above the GDCS pool following the LOCA for suppressing pressure rise within the containment vessel. A method of operation includes channeling steam released into the drywell following the LOCA into the wetwell pool for cooling along with the non-condensable gas carried therewith. The GDCS pool is then drained by gravity, and the wetwell plenum is vented into the GDCS plenum for channeling the non-condensable gas thereto. 6 figures.

  6. Ion transport membrane module and vessel system

    DOEpatents

    Stein, VanEric Edward [Allentown, PA; Carolan, Michael Francis [Allentown, PA; Chen, Christopher M [Allentown, PA; Armstrong, Phillip Andrew [Orefield, PA; Wahle, Harold W [North Canton, OH; Ohrn, Theodore R [Alliance, OH; Kneidel, Kurt E [Alliance, OH; Rackers, Keith Gerard [Louisville, OH; Blake, James Erik [Uniontown, OH; Nataraj, Shankar [Allentown, PA; Van Doorn, Rene Hendrik Elias; Wilson, Merrill Anderson [West Jordan, UT

    2012-02-14

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an exterior, an inlet, and an outlet; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region, wherein any inlet and any outlet of the pressure vessel are in flow communication with exterior regions of the membrane modules; and (c) one or more gas manifolds in flow communication with interior regions of the membrane modules and with the exterior of the pressure vessel. The ion transport membrane system may be utilized in a gas separation device to recover oxygen from an oxygen-containing gas or as an oxidation reactor to oxidize compounds in a feed gas stream by oxygen permeated through the mixed metal oxide ceramic material of the membrane modules.

  7. Ion transport membrane module and vessel system

    DOEpatents

    Stein, VanEric Edward [Allentown, PA; Carolan, Michael Francis [Allentown, PA; Chen, Christopher M [Allentown, PA; Armstrong, Phillip Andrew [Orefield, PA; Wahle, Harold W [North Canton, OH; Ohrn, Theodore R [Alliance, OH; Kneidel, Kurt E [Alliance, OH; Rackers, Keith Gerard [Louisville, OH; Blake, James Erik [Uniontown, OH; Nataraj, Shankar [Allentown, PA; van Doorn, Rene Hendrik Elias; Wilson, Merrill Anderson [West Jordan, UT

    2008-02-26

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an exterior, an inlet, and an outlet; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region, wherein any inlet and any outlet of the pressure vessel are in flow communication with exterior regions of the membrane modules; and (c) one or more gas manifolds in flow communication with interior regions of the membrane modules and with the exterior of the pressure vessel.The ion transport membrane system may be utilized in a gas separation device to recover oxygen from an oxygen-containing gas or as an oxidation reactor to oxidize compounds in a feed gas stream by oxygen permeated through the mixed metal oxide ceramic material of the membrane modules.

  8. Real-time visualization of early metastasis events in Danio rerio

    NASA Astrophysics Data System (ADS)

    Tanner, Kandice

    Metastasis, the process by which cancer cells travel from a primary tumor to establish lesions in distant organs, is the cause of most cancer-related deaths. One critical process during metastasis is the transit of cells from a primary tumor and through the vasculature or lymphatic systems to a distant site prior to metastatic colonization. However, visualization of cellular behavior in the vasculature is difficult in most model systems, where final cell destination is not known beforehand. Here, we used bone- and brain-tropic subclones of MDA-MB-231 breast adenocarcinoma cells (231BO and 231BR, respectively) injected into the circulation of embryonic zebrafish as a model xenograft system of metastasis. The zebrafish vasculature contains vessels on the scale of human capillaries. Real-time intravital imaging revealed metastatic spread to be an inefficient process, with less than 20% of cells passing through a given organ remaining there following 14 h of imaging. Additionally, there was no significant difference in the organ-specific residence time or migration speed of single 231BO and 231BR cells in the organ vasculature. Instead, cell capture was dependent on vessel topography and the function of integrin β1. Interestingly, a fraction of cells extravasated from the vasculature and survived in a perivascular position in the head and caudal venous plexus for up to two weeks. In conclusion, use of the zebrafish vasculature as a model capillary bed has revealed critical steps in early metastasis that are difficult to capture in other systems.

  9. A small scale remote cooling system for a superconducting cyclotron magnet

    NASA Astrophysics Data System (ADS)

    Haug, F.; Berkowitz Zamorra, D.; Michels, M.; Gomez Bosch, R.; Schmid, J.; Striebel, A.; Krueger, A.; Diez, M.; Jakob, M.; Keh, M.; Herberger, W.; Oesterle, D.

    2017-02-01

    Through a technology transfer program CERN is involved in the R&D of a compact superconducting cyclotron for future clinical radioisotope production, a project led by the Spanish research institute CIEMAT. For the remote cooling of the LTc superconducting magnet operating at 4.5 K, CERN has designed a small scale refrigeration system, the Cryogenic Supply System (CSS). This refrigeration system consists of a commercial two-stage 1.5 W @ 4.2 K GM cryocooler and a separate forced flow circuit. The forced flow circuit extracts the cooling power of the first and the second stage cold tips, respectively. Both units are installed in a common vacuum vessel and, at the final configuration, a low loss transfer line will provide the link to the magnet cryostat for the cooling of the thermal shield with helium at 40 K and the two superconducting coils with two-phase helium at 4.5 K. Currently the CSS is in the testing phase at CERN in stand-alone mode without the magnet and the transfer line. We have added a “validation unit” housed in the vacuum vessel of the CSS representing the thermo-hydraulic part of the cyclotron magnet. It is equipped with electrical heaters which allow the simulation of the thermal loads of the magnet cryostat. A cooling power of 1.4 W at 4.5 K and 25 W at the thermal shield temperature level has been measured. The data produced confirm the design principle of the CSS which could be validated.

  10. Cooling water distribution system

    DOEpatents

    Orr, Richard

    1994-01-01

    A passive containment cooling system for a nuclear reactor containment vessel. Disclosed is a cooling water distribution system for introducing cooling water by gravity uniformly over the outer surface of a steel containment vessel using an interconnected series of radial guide elements, a plurality of circumferential collector elements and collector boxes to collect and feed the cooling water into distribution channels extending along the curved surface of the steel containment vessel. The cooling water is uniformly distributed over the curved surface by a plurality of weirs in the distribution channels.

  11. 75 FR 7361 - International Fisheries; Western and Central Pacific Fisheries for Highly Migratory Species...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-19

    ..., to April 21, 2010. The rule establishes regulations needed to carry out the obligations of the United..., vessel monitoring systems, vessel observers, vessel markings, reporting and recordkeeping, at-sea...

  12. 46 CFR 153.9 - Foreign flag vessel endorsement application.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... classes the vessel. (7) A brief description of the vessel's cargo containment systems. (8) Hull type... French. [CGD 73-96, 42 FR 49027, Sept. 26, 1977] Editorial Note: For Federal Register citations affecting...

  13. 46 CFR 153.9 - Foreign flag vessel endorsement application.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... classes the vessel. (7) A brief description of the vessel's cargo containment systems. (8) Hull type... French. [CGD 73-96, 42 FR 49027, Sept. 26, 1977] Editorial Note: For Federal Register citations affecting...

  14. Low frequency mechanical actuation accelerates reperfusion in-vitro

    PubMed Central

    2013-01-01

    Background Rapid restoration of vessel patency after acute myocardial infarction is key to reducing myocardial muscle death and increases survival rates. Standard therapies include thrombolysis and direct PTCA. Alternative or adjunctive emergency therapies that could be initiated by minimally trained personnel in the field are of potential clinical benefit. This paper evaluates a method of accelerating reperfusion through application of low frequency mechanical stimulus to the blood carrying vessels. Materials and method We consider a stenosed, heparinized flow system with aortic-like pressure variations subject to direct vessel vibration at the occlusion site or vessel deformation proximal and distal to the occlusion site, versus a reference system lacking any form of mechanical stimulus on the vessels. Results The experimental results show limited effectiveness of the direct mechanical vibration method and a drastic increase in the patency rate when vessel deformation is induced. For vessel deformation at occlusion site 95% of clots perfused within 11 minutes of application of mechanical stimulus, for vessel deformation 60 centimeters from the occlusion site 95% percent of clots perfused within 16 minutes of stimulus application, while only 2.3% of clots perfused within 20 minutes in the reference system. Conclusion The presented in-vitro results suggest that low frequency mechanical actuation applied during the pre-hospitalization phase in patients with acute myocardial infarction have potential of being a simple and efficient adjunct therapy. PMID:24257116

  15. The Role of the Distal Runoff Vessel of the Descending Branch of the Lateral Circumflex Femoral System in Anterolateral Thigh Flap Surgery: A Case Series and Literature Review.

    PubMed

    He, Xiao-Qing; Zhu, Yue-Liang; Wang, Yi; Mei, Liang-Bin; Jin, Tao; Xu, Yong-Qing

    2016-01-01

    As a distal portion of the descending branch of the lateral circumflex femoral system (LCFS), the role of the distal runoff vessel in anterolateral thigh (ALT) flap surgery has long been overlooked. Recently, however, the distal runoff vessel has been increasingly used in many aspects of ALT flap surgery, and it has exhibited superior properties in solving some difficult problems. Fourteen ALT flaps using the distal runoff vessel of the descending branch of the LCFS for extremity defects were retrospectively reviewed, and recent reports on using the distal runoff vessel were reviewed to determine the role of this vessel in ALT flap surgery. In our series, the distal runoff vessel was used as a flow-through pattern in 10 cases, as a recombined chimeric flap in 2 cases, and as a backup vessel for flap salvage in 2 cases. All of the ALT flaps completely survived. None of the donor sites presented with additional morbidity as a result of harvesting the distal runoff vessel. In the literature review, the following are 5 other options for using the distal runoff vessel: in interposition artery and vein grafts, as the pedicle of the reverse-flow ALT flap, as the recipient vessel, to avoid twisting, and as a monitoring method. The distal runoff vessel of the descending branch of the LCFS could be used for many aspects of the ALT flap surgery, and this vessel plays an irreplaceable role in some difficult reconstruction surgeries.

  16. 40 CFR 63.11140 - Am I subject to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... copolymers production affected source is the facility-wide collection of PVCPU, storage vessels, heat exchange systems, surge control vessels, and wastewater and process wastewater treatment systems that are...

  17. 40 CFR 63.11140 - Am I subject to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... copolymers production affected source is the facility-wide collection of PVCPU, storage vessels, heat exchange systems, surge control vessels, and wastewater and process wastewater treatment systems that are...

  18. 40 CFR 63.11140 - Am I subject to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... copolymers production affected source is the facility-wide collection of PVCPU, storage vessels, heat exchange systems, surge control vessels, and wastewater and process wastewater treatment systems that are...

  19. Hydro-ball in-core instrumentation system and method of operation

    DOEpatents

    Tower, Stephen N.; Veronesi, Luciano; Braun, Howard E.

    1990-01-01

    A hydro-ball in-core instrumentation system employs detector strings each comprising a wire having radiation sensitive balls affixed diametrically at spaced positions therealong and opposite tip ends of which are transportable by fluid drag through interior passageways. In the passageways primary coolant is caused to flow selectively in first and second opposite directions for transporting the detector strings from stored positions in an exterior chamber to inserted positions within the instrumentation thimbles of the fuel rod assemblies of a pressure vessel, and for return. The coolant pressure within the detector passageways is the same as that within the vessel; face contact, disconnectable joints between sections of the interior passageways within the vessel facilitate assembly and disassembly of the vessel for refueling and routine maintenance operations. The detector strings may pass through a very short bend radius thereby minimizing space requirements for the connections of the instrumentation system to the vessel and concomitantly the vessel containment structure. Improved radiation mapping and a significant reduction in potential exposure of personnel to radiation are provided. Both top head and bottom head penetration embodiments are disclosed.

  20. NASA-USRP Summer 2013 Internship Final Report

    NASA Technical Reports Server (NTRS)

    Gurganus, S. Christine

    2013-01-01

    Three major projects were undertaken during the Summer 2013 USRP Internship: (A) assisting the cTAPS group with component and pressure vessel system analyses and documentation, (B) designing a hoisting fixture for a solid rocket motor, (C) finding an alternative to removing the DOT rated gaseous nitrogen tank from the roof for hydrostatic testing. Hypergolic Material Assessments (HMAs) and pressure calculations were performed on components of pressure systems. Additionally, component information was logged in the Standard Parts Database to provide a location where system designers can find information regarding components, including their specifications and compatibility with fluids. A hoisting fixture was designed to hoist a solid rocket motor and meets the specifications related to stress and size. However, there are issues with the fixtures bolt head allotment, the bolt spacing, and the complexity of the part. Finally, calculations were performed on an expiring DOT rated gaseous nitrogen tank in an attempt to re-rate it per ASME standards. This was unsuccessful so other options are being explored for the tank. While much progress was made on all three projects, there is still work to be performed on each project to achieve the desired results.

  1. Magnetically coupled system for mixing

    DOEpatents

    Miller, III, Harlan; Meichel, George; Legere, Edward; Malkiel, Edwin; Woods, Robert Paul; Ashley, Oliver; Katz, Joseph; Ward, Jason; Petersen, Paul

    2015-09-22

    The invention provides a mixing system comprising a magnetically coupled drive system and a foil for cultivating algae, or cyanobacteria, in an open or enclosed vessel. The invention provides effective mixing, low energy usage, low capital expenditure, and ease of drive system component maintenance while maintaining the integrity of a sealed mixing vessel.

  2. Magnetically coupled system for mixing

    DOEpatents

    Miller, III, Harlan; Meichel, George; Legere, Edward; Malkiel, Edwin; Woods, Robert Paul; Ashley, Oliver; Katz, Joseph; Ward, Jason; Petersen, Paul

    2014-04-01

    The invention provides a mixing system comprising a magnetically coupled drive system and a foil for cultivating algae, or cyanobacteria, in an open or enclosed vessel. The invention provides effective mixing, low energy usage, low capital expenditure, and ease of drive system component maintenance while maintaining the integrity of a sealed mixing vessel.

  3. 46 CFR 185.320 - Steering gear, controls, and communication system tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Steering gear, controls, and communication system tests... gear, controls, and communication system tests. The master of a vessel shall have examined and tested the steering gear, signaling whistle, propulsion controls, and communication systems of the vessel...

  4. 46 CFR 185.320 - Steering gear, controls, and communication system tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Steering gear, controls, and communication system tests... gear, controls, and communication system tests. The master of a vessel shall have examined and tested the steering gear, signaling whistle, propulsion controls, and communication systems of the vessel...

  5. 46 CFR 28.855 - Electrical distribution systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Electrical distribution systems. 28.855 Section 28.855... FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.855 Electrical distribution systems. (a) Each electrical distribution system which has a neutral bus or conductor must have the neutral bus or conductor...

  6. 46 CFR 28.855 - Electrical distribution systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Electrical distribution systems. 28.855 Section 28.855... FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.855 Electrical distribution systems. (a) Each electrical distribution system which has a neutral bus or conductor must have the neutral bus or conductor...

  7. 46 CFR 28.855 - Electrical distribution systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Electrical distribution systems. 28.855 Section 28.855... FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.855 Electrical distribution systems. (a) Each electrical distribution system which has a neutral bus or conductor must have the neutral bus or conductor...

  8. 46 CFR 28.855 - Electrical distribution systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Electrical distribution systems. 28.855 Section 28.855... FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.855 Electrical distribution systems. (a) Each electrical distribution system which has a neutral bus or conductor must have the neutral bus or conductor...

  9. 46 CFR 185.320 - Steering gear, controls, and communication system tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Steering gear, controls, and communication system tests... gear, controls, and communication system tests. The master of a vessel shall have examined and tested the steering gear, signaling whistle, propulsion controls, and communication systems of the vessel...

  10. Reactor water cleanup system

    DOEpatents

    Gluntz, D.M.; Taft, W.E.

    1994-12-20

    A reactor water cleanup system includes a reactor pressure vessel containing a reactor core submerged in reactor water. First and second parallel cleanup trains are provided for extracting portions of the reactor water from the pressure vessel, cleaning the extracted water, and returning the cleaned water to the pressure vessel. Each of the cleanup trains includes a heat exchanger for cooling the reactor water, and a cleaner for cleaning the cooled reactor water. A return line is disposed between the cleaner and the pressure vessel for channeling the cleaned water thereto in a first mode of operation. A portion of the cooled water is bypassed around the cleaner during a second mode of operation and returned through the pressure vessel for shutdown cooling. 1 figure.

  11. Interstitial fluid flow and drug delivery in vascularized tumors: a computational model.

    PubMed

    Welter, Michael; Rieger, Heiko

    2013-01-01

    Interstitial fluid is a solution that bathes and surrounds the human cells and provides them with nutrients and a way of waste removal. It is generally believed that elevated tumor interstitial fluid pressure (IFP) is partly responsible for the poor penetration and distribution of therapeutic agents in solid tumors, but the complex interplay of extravasation, permeabilities, vascular heterogeneities and diffusive and convective drug transport remains poorly understood. Here we consider-with the help of a theoretical model-the tumor IFP, interstitial fluid flow (IFF) and its impact upon drug delivery within tumor depending on biophysical determinants such as vessel network morphology, permeabilities and diffusive vs. convective transport. We developed a vascular tumor growth model, including vessel co-option, regression, and angiogenesis, that we extend here by the interstitium (represented by a porous medium obeying Darcy's law) and sources (vessels) and sinks (lymphatics) for IFF. With it we compute the spatial variation of the IFP and IFF and determine its correlation with the vascular network morphology and physiological parameters like vessel wall permeability, tissue conductivity, distribution of lymphatics etc. We find that an increased vascular wall conductivity together with a reduction of lymph function leads to increased tumor IFP, but also that the latter does not necessarily imply a decreased extravasation rate: Generally the IF flow rate is positively correlated with the various conductivities in the system. The IFF field is then used to determine the drug distribution after an injection via a convection diffusion reaction equation for intra- and extracellular concentrations with parameters guided by experimental data for the drug Doxorubicin. We observe that the interplay of convective and diffusive drug transport can lead to quite unexpected effects in the presence of a heterogeneous, compartmentalized vasculature. Finally we discuss various strategies to increase drug exposure time of tumor cells.

  12. 48 CFR 47.303-9 - F.o.b. vessel, port of shipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false F.o.b. vessel, port of... CONTRACT MANAGEMENT TRANSPORTATION Transportation in Supply Contracts 47.303-9 F.o.b. vessel, port of shipment. (a) Explanation of delivery term. F.o.b. vessel, port shipment means free of expense to the...

  13. 36 CFR 13.1150 - Is a permit required for a vessel in Glacier Bay?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... vessel in Glacier Bay? 13.1150 Section 13.1150 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay National Park and Preserve Vessel Permits § 13.1150 Is a permit required for a vessel in Glacier Bay? A permit from...

  14. 36 CFR 13.1150 - Is a permit required for a vessel in Glacier Bay?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... vessel in Glacier Bay? 13.1150 Section 13.1150 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay National Park and Preserve Vessel Permits § 13.1150 Is a permit required for a vessel in Glacier Bay? A permit from...

  15. 36 CFR 13.1150 - Is a permit required for a vessel in Glacier Bay?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... vessel in Glacier Bay? 13.1150 Section 13.1150 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay National Park and Preserve Vessel Permits § 13.1150 Is a permit required for a vessel in Glacier Bay? A permit from...

  16. 36 CFR 13.1150 - Is a permit required for a vessel in Glacier Bay?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... vessel in Glacier Bay? 13.1150 Section 13.1150 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay National Park and Preserve Vessel Permits § 13.1150 Is a permit required for a vessel in Glacier Bay? A permit from...

  17. Lorentz force detuning analysis of the Spallation Neutron Source (SNS) accelerating cavities.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, R.R.; Matsumoto, K. Y.; Ciovati, G.

    2001-01-01

    The Spallation Neutron Source (SNS) project incorporates a superconducting radio-frequency (SRF) accelerator for the final section of the pulsed mode linac. Cavities with geometrical {beta} values of {beta}=0.61 and {beta}=0.81 are utilized in the SRF section, and are constructed out of thin-walled niobium with stiffener rings welded between the cells near the iris. The welded titanium helium vessel and tuner assembly restrains the cavity beam tubes. Cavities with {beta} values less than one have relatively steep and flat side-walls making the cavities susceptible to Lorentz force detuning. In addition, the pulsed RF induces cyclic Lorentz pressures that mechanically excite themore » cavities, producing a dynamic Lorentz force detuning different from a continuous RF system. The amplitude of the dynamic detuning for a given cavity design is a function of the mechanical damping, stiffness of the tuner/helium vessel assembly, RF pulse profile, and the RF pulse rate. This paper presents analysis and testing results to date, and indicates areas where more investigation is required.« less

  18. Spire, an actin nucleation factor, regulates cell division during Drosophila heart development.

    PubMed

    Xu, Peng; Johnson, Tamara L; Stoller-Conrad, Jessica R; Schulz, Robert A

    2012-01-01

    The Drosophila dorsal vessel is a beneficial model system for studying the regulation of early heart development. Spire (Spir), an actin-nucleation factor, regulates actin dynamics in many developmental processes, such as cell shape determination, intracellular transport, and locomotion. Through protein expression pattern analysis, we demonstrate that the absence of spir function affects cell division in Myocyte enhancer factor 2-, Tinman (Tin)-, Even-skipped- and Seven up (Svp)-positive heart cells. In addition, genetic interaction analysis shows that spir functionally interacts with Dorsocross, tin, and pannier to properly specify the cardiac fate. Furthermore, through visualization of double heterozygous embryos, we determines that spir cooperates with CycA for heart cell specification and division. Finally, when comparing the spir mutant phenotype with that of a CycA mutant, the results suggest that most Svp-positive progenitors in spir mutant embryos cannot undergo full cell division at cell cycle 15, and that Tin-positive progenitors are arrested at cell cycle 16 as double-nucleated cells. We conclude that Spir plays a crucial role in controlling dorsal vessel formation and has a function in cell division during heart tube morphogenesis.

  19. Primary Intestinal Lymphangiectasia Manifested as Unusual Edemas and Effusions: A Case Report.

    PubMed

    Wang, Xuefeng; Jin, Hong; Wu, Weilu

    2016-03-01

    Primary intestinal lymphangiectasia (PIL) is a rare disorder of unknown etiology characterized by diffuse or localized dilation and eventual rupture of the enteric lymphatic vessels in mucosa, submucosa, and/or subserosa. Lymph, rich in all kinds of proteins and lymphocytes, leaks into the gastrointestinal tract via the affected lymphatic vessels causing hypoproteinemia and lymphopenia. The main symptom is variable degrees of pitting edemas of bilateral lower limbs. But edemas of any other parts of body, and mild serous effusions may also occur sometimes. PIL occurs in conjunction with a right hemifacial edema, a right upper limb lymphedema, asymmetric bilateral calves edemas, and a unilateral massive pleural effusion seems never to be reported before. In addition, increased enteric protein loss that may cause severe hypoproteinemia usually get overlooked, and the lymphatic system disorders always put the diagnoses in a dilemma.We described a case of a 17-year-old Chinese girl with a history of gradually progressive swellings of right-sided face, right upper limb, and bilateral calves since 3 to 4 months of age. A right-sided massive pleural effusion, a moderate pericardial effusion, and a mild ascites have been proved unchanged by a series of computerized tomography (CT) scans since 5 years ago. The diagnosis of PIL was finally confirmed by severe hypoproteinemia, endoscopic changes, and histology of jejunum biopsy. Further lymphoscintigraphy and lymphangiography also identified lymph leakage in her bowel and several abnormal lymphatic vessels. A high-protein, low-fat diet supplemented with medium-chain triglycerides (MCT) showed some benefit.This case suggested that PIL was a rare but important etiology of hypoproteinemia, effusions, and edemas. PIL, effusions, and lymphedema can be the features of multisegmental generalized lymphatic dysplasia. In addition, both lymphoscintigraphy and intranodal lymphangiography could be considered when lymphatic system disorders are suspected.

  20. Primary Intestinal Lymphangiectasia Manifested as Unusual Edemas and Effusions

    PubMed Central

    Wang, Xuefeng; Jin, Hong; Wu, Weilu

    2016-01-01

    Abstract Primary intestinal lymphangiectasia (PIL) is a rare disorder of unknown etiology characterized by diffuse or localized dilation and eventual rupture of the enteric lymphatic vessels in mucosa, submucosa, and/or subserosa. Lymph, rich in all kinds of proteins and lymphocytes, leaks into the gastrointestinal tract via the affected lymphatic vessels causing hypoproteinemia and lymphopenia. The main symptom is variable degrees of pitting edemas of bilateral lower limbs. But edemas of any other parts of body, and mild serous effusions may also occur sometimes. PIL occurs in conjunction with a right hemifacial edema, a right upper limb lymphedema, asymmetric bilateral calves edemas, and a unilateral massive pleural effusion seems never to be reported before. In addition, increased enteric protein loss that may cause severe hypoproteinemia usually get overlooked, and the lymphatic system disorders always put the diagnoses in a dilemma. We described a case of a 17-year-old Chinese girl with a history of gradually progressive swellings of right-sided face, right upper limb, and bilateral calves since 3 to 4 months of age. A right-sided massive pleural effusion, a moderate pericardial effusion, and a mild ascites have been proved unchanged by a series of computerized tomography (CT) scans since 5 years ago. The diagnosis of PIL was finally confirmed by severe hypoproteinemia, endoscopic changes, and histology of jejunum biopsy. Further lymphoscintigraphy and lymphangiography also identified lymph leakage in her bowel and several abnormal lymphatic vessels. A high-protein, low-fat diet supplemented with medium-chain triglycerides (MCT) showed some benefit. This case suggested that PIL was a rare but important etiology of hypoproteinemia, effusions, and edemas. PIL, effusions, and lymphedema can be the features of multisegmental generalized lymphatic dysplasia. In addition, both lymphoscintigraphy and intranodal lymphangiography could be considered when lymphatic system disorders are suspected. PMID:26962779

  1. Noble gas, iodine, and cesium transport in a postulated loss of decay heat removal accident at Browns Ferry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wichner, R.P.; Hodge, S.A.; Weber, C.F.

    1984-08-01

    This report presents an analysis of the movement of noble gas, iodine, and cesium fission products within the Mark-I containment BWR reactor system represented by Browns Ferry Unit 1 during a postulated accident sequence initiated by a loss of decay heat removal capability following a scram. The event analysis showed that this accident could be brought under control by various means, but the sequence with no operator action ultimately leads to containment (drywell) failure followed by loss of water from the reactor vessel, core degradation due to overheating, and reactor vessel failure with attendant movement of core debris onto themore » drywell floor. The analysis of fission product transport presented in this report is based on the no-operator-action sequence and provides an estimate of fission product inventories, as a function of time, within 14 control volumes outside the core, with the atmosphere considered as the final control volume in the transport sequence. As in the case of accident sequences previously studied, we find small barrier for noble gas ejection to air, these gases being effectively purged from the drywell and reactor building by steam and concrete degradation gases. However, significant decay of krypton isotopes occurs during the long delay times involved in this sequence. In contrast, large degrees of holdup for iodine and cesium are projected due to the chemical reactivity of these elements. Only about 2 x 10/sup -4/% of the initial iodine and cesium activity are predicted to be released to the atmosphere. Principal barriers for release are deposition on reactor vessel and containment walls. A significant amount of iodine is captured in the water pool formed in the reactor building basement after actuation of the fire protection system.« less

  2. An in situ optical imaging system for measuring lipid uptake, vessel contraction, and lymph flow in small animal lymphatic vessels

    NASA Astrophysics Data System (ADS)

    Kassis, Timothy; Weiler, Michael J.; Dixon, J. Brandon

    2012-03-01

    All dietary lipids are transported to venous circulation through the lymphatic system, yet the underlying mechanisms that regulate this process remain unclear. Understanding how the lymphatics functionally respond to changes in lipid load is important in the diagnosis and treatment of lipid and lymphatic related diseases such as obesity, hypercholesterolemia, and lymphedema. Therefore, we sought to develop an in situ imaging system to quantify and correlate lymphatic function as it relates to lipid transport. A custom-built optical set-up provides us with the capability of dual-channel imaging of both high-speed bright-field video and fluorescence simultaneously. This is achieved by dividing the light path into two optical bands. Utilizing high-speed and back-illuminated CCD cameras and post-acquisition image processing algorithms, we have the potential quantify correlations between vessel contraction, lymph flow and lipid concentration of mesenteric lymphatic vessels in situ. Local flow velocity is measured through lymphocyte tracking, vessel contraction through measurements of the vessel walls and lipid uptake through fluorescence intensity tracking of a fluorescent long chain fatty acid analogue, Bodipy FL C16. This system will prove to be an invaluable tool for both scientists studying lymphatic function in health and disease, and those investigating strategies for targeting the lymphatic system with orally delivered drugs.

  3. BETA (Bitter Electromagnet Testing Apparatus)

    NASA Astrophysics Data System (ADS)

    Bates, Evan M.; Birmingham, William J.; Rivera, William F.; Romero-Talamas, Carlos A.

    2017-10-01

    The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) prototype of the 10-T Adjustable Long Pulse High-Field Apparatus (ALPHA). These water-cooled resistive magnets use high DC currents to produce strong uniform magnetic fields. Presented here is the successful completion of the BETA project and experimental results validating analytical magnet designing methods developed at the Dusty Plasma Laboratory (DPL). BETA's final design specifications will be highlighted which include electromagnetic, thermal and stress analyses. The magnet core design will be explained which include: Bitter Arcs, helix starters, and clamping annuli. The final version of the magnet's vessel and cooling system are also presented, as well as the electrical system of BETA, which is composed of a unique solid-state breaker circuit. Experimental results presented will show the operation of BETA at 1 T. The results are compared to both analytical design methods and finite element analysis calculations. We also explore the steady state maximums and theoretical limits of BETA's design. The completion of BETA validates the design and manufacturing techniques that will be used in the succeeding magnet, ALPHA.

  4. Accurate Image Analysis of the Retina Using Hessian Matrix and Binarisation of Thresholded Entropy with Application of Texture Mapping

    PubMed Central

    Yin, Xiaoxia; Ng, Brian W-H; He, Jing; Zhang, Yanchun; Abbott, Derek

    2014-01-01

    In this paper, we demonstrate a comprehensive method for segmenting the retinal vasculature in camera images of the fundus. This is of interest in the area of diagnostics for eye diseases that affect the blood vessels in the eye. In a departure from other state-of-the-art methods, vessels are first pre-grouped together with graph partitioning, using a spectral clustering technique based on morphological features. Local curvature is estimated over the whole image using eigenvalues of Hessian matrix in order to enhance the vessels, which appear as ridges in images of the retina. The result is combined with a binarized image, obtained using a threshold that maximizes entropy, to extract the retinal vessels from the background. Speckle type noise is reduced by applying a connectivity constraint on the extracted curvature based enhanced image. This constraint is varied over the image according to each region's predominant blood vessel size. The resultant image exhibits the central light reflex of retinal arteries and veins, which prevents the segmentation of whole vessels. To address this, the earlier entropy-based binarization technique is repeated on the original image, but crucially, with a different threshold to incorporate the central reflex vessels. The final segmentation is achieved by combining the segmented vessels with and without central light reflex. We carry out our approach on DRIVE and REVIEW, two publicly available collections of retinal images for research purposes. The obtained results are compared with state-of-the-art methods in the literature using metrics such as sensitivity (true positive rate), selectivity (false positive rate) and accuracy rates for the DRIVE images and measured vessel widths for the REVIEW images. Our approach out-performs the methods in the literature. PMID:24781033

  5. 75 FR 16072 - Fisheries Finance Program; Final Program Notice and Announcement of Availability of Federal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-31

    ...NMFS announces the availability of long-term direct loans made underthe Fisheries Finance Program (FFP). The FFP provides financing for the purchase of used vessels or the reconstruction of vessels (limited to reconstructions that do not add to fishing capacity); refinancing for existing debt obligations; financing or refinancing fisheries shoreside facilities or aquacultural facilities; and the purchase or refinancing of Individual Fishing Quota (IFQ) in the North Pacific. FFP loans are not issued for purposes which could contribute to over capitalization of the fishing industry.

  6. A consonant construction of the hyaloid and retinal vascular systems by the angiogenic process.

    PubMed

    Gergely, K; Gerinec, A

    2011-01-01

    There has been much debate as to whether the retinal vasculature forms by angiogenesis or vasculogenesis, thus angiogenesis is now accepted. We suppose that signals necessary for proper localization and development of the hyaloid and retinal vascular systems are already in place prior to the time at which these systems are developed. The remarkable conservation of vascular patterning suggests that specific genetic programs coordinate its formation. Evidence for a genetic program comes particularly from the characterization of gene-targeted mice and mutational analysis in zebrafish, but the exact genetic pathways remain poorly defined. Considering all the things from the aspect of angiogenesis significant differences exist between the mentioned vascular systems only in their lifetime (a) and location (b): (a) The hyaloid vasculature is a complex of transient intraocular vessels, while the retinal vessels are adapted for the whole life. (b) The hyaloid system fills the interior of the optic cup and this way "occupies" three-dimensional space while the distribution of the retinal vessels is relatively planar (two-dimensional) in the retina. We assume that retinal vessels are "built" in the same manner as the hyaloid vasculature and the outcomes at the embryological, histological, cellular and molecular levels confirm it. We show a consonant construction of both systems. The human organism does not have any rational reason to build up one system (i.e. the hyaloid vasculature) by angiogenesis and practically the same system (i.e. the retinal vessels) by another, de novo process, in the eye. It would be a waste of energy and various essential molecules. Thus, it seems that the retinal vascular system is an advanced copy of the hyaloid vessels (Tab. 1, Ref. 143).

  7. Triple In Situ Antegrade Laser Fenestration of Aortic Stent-Graft Extension Using Fusion Imaging for Urgent Treatment of Symptomatic Abdominal Aneurysm with Type 1 Endoleak.

    PubMed

    Touma, Joseph; Kobeiter, Hicham; Majewski, Marek; Tacher, Vania; Desgranges, Pascal

    2018-03-01

    The present report describes the management of massive proximal type 1 endoleak with an enlarged symptomatic aneurysmal sac. Urgent treatment was performed using in situ laser fenestration of an aortic proximal extension facing renovisceral ostia. Image fusion was obtained intraoperatively. For each target vessel (superior mesenteric and two renal arteries), an Aptus HeliFX steerable sheath (Medtronic) inserted through femoral access was curved to face the vessel's ostium marker. A laser catheter (Spectranetics) was used to traverse the stent-graft and insert a 0.014" guidewire in the vessel. The fenestration was enlarged using a 2.5-mm-diameter cutting balloon, followed by a 4-mm-diameter balloon angioplasty and a V12 I Cast/Advanta covered stent implantation. Final angiogram demonstrated aneurysm exclusion and patent target vessels. The postoperative course and 7 months follow-up were uneventful. Level of evidence Level 4.

  8. Computer-aided diagnostic detection system of venous beading in retinal images

    NASA Astrophysics Data System (ADS)

    Yang, Ching-Wen; Ma, DyeJyun; Chao, ShuennChing; Wang, ChuinMu; Wen, Chia-Hsien; Lo, ChienShun; Chung, Pau-Choo; Chang, Chein-I.

    2000-05-01

    The detection of venous beading in retinal images provides an early sign of diabetic retinopathy and plays an important role as a preprocessing step in diagnosing ocular diseases. We present a computer-aided diagnostic system to automatically detect venous beading of blood vessels. It comprises of two modules, referred to as the blood vessel extraction module and the venus beading detection module. The former uses a bell-shaped Gaussian kernel with 12 azimuths to extract blood vessels while the latter applies a neural network-based shape cognitron to detect venous beading among the extracted blood vessels for diagnosis. Both modules are fully computer-automated. To evaluate the proposed system, 61 retinal images (32 beaded and 29 normal images) are used for performance evaluation.

  9. Jam proof closure assembly for lidded pressure vessels

    DOEpatents

    Cioletti, Olisse C.

    1992-01-01

    An expendable closure assembly is provided for use (in multiple units) with a lockable pressure vessel cover along its rim, such as of an autoclave. This assembly is suited to variable compressive contact and locking with the vessel lid sealing gasket. The closure assembly consists of a thick walled sleeve insert for retention in the under bores fabricated in the cover periphery and the sleeve is provided with internal threading only. A snap serves as a retainer on the underside of the sleeve, locking it into an under bore retention channel. Finally, a standard elongate externally threaded bolt is sized for mating cooperation with the so positioned sleeve, whereby the location of the bolt shaft in the cover bore hole determines its compressive contact on the underlying gasket.

  10. Nonrigid registration of 3D longitudinal optical coherence tomography volumes with choroidal neovascularization

    NASA Astrophysics Data System (ADS)

    Wei, Qiangding; Shi, Fei; Zhu, Weifang; Xiang, Dehui; Chen, Haoyu; Chen, Xinjian

    2017-02-01

    In this paper, we propose a 3D registration method for retinal optical coherence tomography (OCT) volumes. The proposed method consists of five main steps: First, a projection image of the 3D OCT scan is created. Second, the vessel enhancement filter is applied on the projection image to detect vessel shadow. Third, landmark points are extracted based on both vessel positions and layer information. Fourth, the coherent point drift method is used to align retinal OCT volumes. Finally, a nonrigid B-spline-based registration method is applied to find the optimal transform to match the data. We applied this registration method on 15 3D OCT scans of patients with Choroidal Neovascularization (CNV). The Dice coefficients (DSC) between layers are greatly improved after applying the nonrigid registration.

  11. Glucose transporter distribution in the vessels of the central nervous system of the axolotl Ambystoma mexicanum (Urodela: Ambystomatidae).

    PubMed

    Lazzari, Maurizio; Bettini, Simone; Ciani, Franco; Franceschini, Valeria

    2008-10-01

    The GLUT-1 isoform of the glucose transporter is commonly considered a reliable molecular marker of blood-brain barrier endothelia in the neural vasculature organized in a three-dimensional network of single vessels. The central nervous system of the axolotl Ambystoma mexicanum is characterized by a vascular architecture that contains both single and paired vessels. The presence and distribution of the GLUT-1 transporter are studied in this urodele using both immunoperoxidase histochemistry and immunogold technique. Light microscopy reveals immunopositivity in both parenchymal and meningeal vessels. The transverse-sectioned pairs of vessels do not show the same size. Furthermore, in the same pair, the two elements often differ in diameter. The main regions of the central nervous system show a different percentage of the paired structures. Only immunogold cytochemistry reveals different staining intensity in the two adjoined elements of a vascular pair. Colloidal gold particles show an asymmetric distribution in the endothelia of both single and paired vessels. These particles are more numerous on the abluminal surface than on the luminal one. The particle density is calculated in both vascular types. The different values could indicate functional differences between single and paired vessels and between the two adjoined elements of a pair, regarding glucose transport.

  12. Two-tank working gas storage system for heat engine

    DOEpatents

    Hindes, Clyde J.

    1987-01-01

    A two-tank working gas supply and pump-down system is coupled to a hot gas engine, such as a Stirling engine. The system has a power control valve for admitting the working gas to the engine when increased power is needed, and for releasing the working gas from the engine when engine power is to be decreased. A compressor pumps the working gas that is released from the engine. Two storage vessels or tanks are provided, one for storing the working gas at a modest pressure (i.e., half maximum pressure), and another for storing the working gas at a higher pressure (i.e., about full engine pressure). Solenoid valves are associated with the gas line to each of the storage vessels, and are selectively actuated to couple the vessels one at a time to the compressor during pumpdown to fill the high-pressure vessel with working gas at high pressure and then to fill the low-pressure vessel with the gas at low pressure. When more power is needed, the solenoid valves first supply the low-pressure gas from the low-pressure vessel to the engine and then supply the high-pressure gas from the high-pressure vessel. The solenoid valves each act as a check-valve when unactuated, and as an open valve when actuated.

  13. On connecting large vessels to small. The meaning of Murray's law

    PubMed Central

    1981-01-01

    A large part of the branching vasculature of the mammalian circulatory and respiratory systems obeys Murray's law, which states that the cube of the radius of a parent vessel equals the sum of the cubes of the radii of the daughters. Where this law is obeyed, a functional relationship exists between vessel radius and volumetric flow, average linear velocity of flow, velocity profile, vessel-wall shear stress, Reynolds number, and pressure gradient in individual vessels. In homogeneous, full-flow sets of vessels, a relation is also established between vessel radius and the conductance, resistance, and cross- sectional area of a full-flow set. PMID:7288393

  14. 46 CFR 120.312 - Power sources on vessels of more than 19.8 meters (65 feet) in length carrying more than 600...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5... 46 Shipping 4 2010-10-01 2010-10-01 false Power sources on vessels of more than 19.8 meters (65...

  15. 46 CFR 120.312 - Power sources on vessels of more than 19.8 meters (65 feet) in length carrying more than 600...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Power sources on vessels of more than 19.8 meters (65... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5...

  16. 46 CFR 120.312 - Power sources on vessels of more than 19.8 meters (65 feet) in length carrying more than 600...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Power sources on vessels of more than 19.8 meters (65... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5...

  17. 46 CFR 120.312 - Power sources on vessels of more than 19.8 meters (65 feet) in length carrying more than 600...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Power sources on vessels of more than 19.8 meters (65... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5...

  18. Calculation and analysis of velocity and viscous drag in an artery with a periodic pressure gradient

    NASA Astrophysics Data System (ADS)

    Alizadeh, M.; Seyedpour, S. M.; Mozafari, V.; Babazadeh, Shayan S.

    2012-07-01

    Blood as a fluid that human and other living creatures are dependent on has been always considered by scientists and researchers. Any changes in blood pressure and its normal velocity can be a sign of a disease. Whatever significant in blood fluid's mechanics is Constitutive equations and finding some relations for analysis and description of drag, velocity and periodic blood pressure in vessels. In this paper, by considering available experimental quantities, for blood pressure and velocity in periodic time of a thigh artery of a living dog, at first it is written into Fourier series, then by solving Navier-Stokes equations, a relation for curve drawing of vessel blood pressure with rigid wall is obtained. Likewise in another part of this paper, vessel wall is taken in to consideration that vessel wall is elastic and its pressure and velocity are written into complex Fourier series. In this case, by solving Navier-Stokes equations, some relations for blood velocity, viscous drag on vessel wall and blood pressure are obtained. In this study by noting that vessel diameter is almost is large (3.7 mm), and blood is considered as a Newtonian fluid. Finally, available experimental quantities of pressure with obtained curve of solving Navier-Stokes equations are compared. In blood analysis in rigid vessel, existence of 48% variance in pressure curve systole peak caused vessel blood flow analysis with elastic wall, results in new relations for blood flow description. The Resultant curve is obtained from new relations holding 10% variance in systole peak.

  19. 46 CFR 77.03-1 - Installation and details.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Marine Engineering Systems § 77.03-1 Installation and details. (a) The installation of all systems of a marine engineering nature, together with the details of design, construction...

  20. Solar thermal power system

    DOEpatents

    Bennett, Charles L.

    2010-06-15

    A solar thermal power generator includes an inclined elongated boiler tube positioned in the focus of a solar concentrator for generating steam from water. The boiler tube is connected at one end to receive water from a pressure vessel as well as connected at an opposite end to return steam back to the vessel in a fluidic circuit arrangement that stores energy in the form of heated water in the pressure vessel. An expander, condenser, and reservoir are also connected in series to respectively produce work using the steam passed either directly (above a water line in the vessel) or indirectly (below a water line in the vessel) through the pressure vessel, condense the expanded steam, and collect the condensed water. The reservoir also supplies the collected water back to the pressure vessel at the end of a diurnal cycle when the vessel is sufficiently depressurized, so that the system is reset to repeat the cycle the following day. The circuital arrangement of the boiler tube and the pressure vessel operates to dampen flow instabilities in the boiler tube, damp out the effects of solar transients, and provide thermal energy storage which enables time shifting of power generation to better align with the higher demand for energy during peak energy usage periods.

  1. 78 FR 61873 - Revisions to the Export Administration Regulations (EAR) To Make the Commerce Control List (CCL...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-04

    ...This final rule implements changes that were proposed on November 29, 2012 in a proposed rule entitled Revisions to the Export Administration Regulations (EAR) To Make the Commerce Control List (CCL) Clearer. The changes in the November 29 proposed rule were informed by public comments received in response to an advance notice of proposed rulemaking entitled Commerce Control List: Revising Descriptions of Items and Foreign Availability published as part of the President's Export Control Reform (ECR) Initiative on December 9, 2010. This final rule implements changes that can be made to the CCL without requiring changes to multilateral export control regime guidelines or lists. This final rule also makes conforming changes and minor clarifications as a result of the publication of two final rules implementing the Export Control Reform Initiative: the April 16, 2013 final rule entitled Revisions to the Export Administration Regulations: Initial Implementation of Export Control Reform; and the July 8, 2013 final rule entitled Revisions to the Export Administration Regulations: Military Vehicles; Vessels of War; Submersible Vessels, Oceanographic Equipment; Related Items; and Auxiliary and Miscellaneous Items that the President Determines No Longer Warrant Control under the United States Munitions List. Lastly, this final rule is making revisions to the EAR as a result of public comments received in response to the November 29 proposed rule and to a notice of inquiry (NOI) entitled Request for Public Comments on Shipping Tolerances for Export Licenses Issued by the Bureau of Industry and Security (BIS), that BIS published on July 5, 2012.

  2. 21 CFR 1250.82 - Potable water systems.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Potable water systems. 1250.82 Section 1250.82... SANITATION Sanitation Facilities and Conditions on Vessels § 1250.82 Potable water systems. The following conditions must be met by vessel water systems used for the storage and distribution of water which has met...

  3. 21 CFR 1250.82 - Potable water systems.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Potable water systems. 1250.82 Section 1250.82... SANITATION Sanitation Facilities and Conditions on Vessels § 1250.82 Potable water systems. The following conditions must be met by vessel water systems used for the storage and distribution of water which has met...

  4. 21 CFR 1250.82 - Potable water systems.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Potable water systems. 1250.82 Section 1250.82... SANITATION Sanitation Facilities and Conditions on Vessels § 1250.82 Potable water systems. The following conditions must be met by vessel water systems used for the storage and distribution of water which has met...

  5. 46 CFR 182.510 - Bilge piping system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Bilge piping system. 182.510 Section 182.510 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) MACHINERY INSTALLATION Bilge and Ballast Systems § 182.510 Bilge piping system. (a) A vessel of at least 7.9...

  6. 46 CFR 182.510 - Bilge piping system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Bilge piping system. 182.510 Section 182.510 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) MACHINERY INSTALLATION Bilge and Ballast Systems § 182.510 Bilge piping system. (a) A vessel of at least 7.9...

  7. Functional Requirements Study

    DTIC Science & Technology

    2008-07-01

    Identification System, AIS, Vessel Traffic Services, VTS, Transmit, Broadcast, Functional Requirements, United States Coast Guard, USCG, Mariner, Electronic ...Chart Systems, ECS, Vessel Operators, National Oceanic Atmospheric Administration, NOAA, US Army Corp of Engineers , USACE, ECDIS 18. Distribution...and River Information Service COPT Captain of the Port DGPS Differential Global Positioning System ECDIS Electronic Chart Display Information System

  8. 46 CFR 27.205 - What are the requirements for internal communication systems on towing vessels?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... systems on towing vessels? 27.205 Section 27.205 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... fitted with a communication system between the engine room and the operating station that— (1) Consists... required to have internal communication systems. (c) When the operating-station's engine controls and the...

  9. 21 CFR 1250.82 - Potable water systems.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Potable water systems. 1250.82 Section 1250.82... SANITATION Sanitation Facilities and Conditions on Vessels § 1250.82 Potable water systems. The following conditions must be met by vessel water systems used for the storage and distribution of water which has met...

  10. 76 FR 38107 - Atlantic Highly Migratory Species; Vessel Monitoring Systems; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-29

    .... 110520295-1295-01] RIN 0648-BA64 Atlantic Highly Migratory Species; Vessel Monitoring Systems; Correction... Monitoring System requirements in Atlantic HMS fisheries. The document contained an incorrect time for a..., 2011 3:30-6:30 p.m Atlantic County Library System, Brigantine Branch, 201 15th St. South, Brigantine...

  11. Scale Up of Malonic Acid Fermentation Process: Cooperative Research and Development Final Report, CRADA Number CRD-16-612

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schell, Daniel J

    The goal of this work is to use the large fermentation vessels in the National Renewable Energy Laboratory's (NREL) Integrated Biorefinery Research Facility (IBRF) to scale-up Lygos' biological-based process for producing malonic acid and to generate performance data. Initially, work at the 1 L scale validated successful transfer of Lygos' fermentation protocols to NREL using a glucose substrate. Outside of the scope of the CRADA with NREL, Lygos tested their process on lignocellulosic sugars produced by NREL at Lawrence Berkeley National Laboratory's (LBNL) Advanced Biofuels Process Development Unit (ABPDU). NREL produced these cellulosic sugar solutions from corn stover using amore » separate cellulose/hemicellulose process configuration. Finally, NREL performed fermentations using glucose in large fermentors (1,500- and 9,000-L vessels) to intermediate product and to demonstrate successful performance of Lygos' technology at larger scales.« less

  12. Effects of air vessel on water hammer in high-head pumping station

    NASA Astrophysics Data System (ADS)

    Wang, L.; Wang, F. J.; Zou, Z. C.; Li, X. N.; Zhang, J. C.

    2013-12-01

    Effects of air vessel on water hammer process in a pumping station with high-head were analyzed by using the characteristics method. The results show that the air vessel volume is the key parameter that determines the protective effect on water hammer pressure. The maximum pressure in the system declines with increasing air vessel volume. For a fixed volume of air vessel, the shape of air vessel and mounting style, such as horizontal or vertical mounting, have little effect on the water hammer. In order to obtain good protection effects, the position of air vessel should be close to the outlet of the pump. Generally, once the volume of air vessel is guaranteed, the water hammer of a entire pipeline is effectively controlled.

  13. 46 CFR 28.345 - Electrical standards for vessels less than 79 feet (24 meters) in length.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Electrical standards for vessels less than 79 feet (24... § 28.345 Electrical standards for vessels less than 79 feet (24 meters) in length. (a) A vessel less than 79 feet (24 meters) in length with an alternating current electrical distribution system may...

  14. 46 CFR 28.345 - Electrical standards for vessels less than 79 feet (24 meters) in length.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Electrical standards for vessels less than 79 feet (24... § 28.345 Electrical standards for vessels less than 79 feet (24 meters) in length. (a) A vessel less than 79 feet (24 meters) in length with an alternating current electrical distribution system may...

  15. 77 FR 23325 - Groundfish Fisheries of the Exclusive Economic Zone off Alaska and Pacific Halibut Fisheries...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-18

    ... monitoring under the fisheries research plan (deployment plan). NMFS would use the ex-vessel value fee... conservation needs, with funds provided through a system of fees based on the ex- vessel value of groundfish... category would pay to NMFS an observer fee based upon the ex-vessel value of fish landed (ex-vessel value...

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krieg, R.

    For future pressurized-water reactors, which should be designed against core-meltdown accidents, missiles generated inside the containment present a severe problem for its integrity. The masses and geometries of the missiles, as well as their velocities, may vary to a great extent. Therefore a reliable proof of the containment integrity is very difficult. In this article the potential sources of missiles are discussed, and the conclusion was reached that the generation of heavy missiles must be prevented. Steam explosions must not damage the reactor vessel head. Thus fragments of the head cannot become missiles that endanger the containment shell. Furthermore, duringmore » a melt-through failure of the reactor vessel under high pressure, the resulting forces must not catapult the whole vessel against the containment shell. Only missiles caused by hydrogen explosions may be tolerable, but shielding structures that protect the containment shell may be required. Further investigations are necessary. Finally, measures are described showing that the generation of heavy missiles can indeed be prevented. Investigations are currently being carried out that will confirm the strength of the reactor vessel head. In addition, a device for retaining the fragments of a failing reactor vessel is discussed.« less

  17. A strain energy filter for 3D vessel enhancement with application to pulmonary CT images.

    PubMed

    Xiao, Changyan; Staring, Marius; Shamonin, Denis; Reiber, Johan H C; Stolk, Jan; Stoel, Berend C

    2011-02-01

    The traditional Hessian-related vessel filters often suffer from detecting complex structures like bifurcations due to an over-simplified cylindrical model. To solve this problem, we present a shape-tuned strain energy density function to measure vessel likelihood in 3D medical images. This method is initially inspired by established stress-strain principles in mechanics. By considering the Hessian matrix as a stress tensor, the three invariants from orthogonal tensor decomposition are used independently or combined to formulate distinctive functions for vascular shape discrimination, brightness contrast and structure strength measuring. Moreover, a mathematical description of Hessian eigenvalues for general vessel shapes is obtained, based on an intensity continuity assumption, and a relative Hessian strength term is presented to ensure the dominance of second-order derivatives as well as suppress undesired step-edges. Finally, we adopt the multi-scale scheme to find an optimal solution through scale space. The proposed method is validated in experiments with a digital phantom and non-contrast-enhanced pulmonary CT data. It is shown that our model performed more effectively in enhancing vessel bifurcations and preserving details, compared to three existing filters. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. NEURONAL ACTION ON THE DEVELOPING BLOOD VESSEL PATTERN

    PubMed Central

    James, Jennifer M.; Mukouyama, Yoh-suke

    2011-01-01

    The nervous system relies on a highly specialized network of blood vessels for development and neuronal survival. Recent evidence suggests that both the central and peripheral nervous systems (CNS and PNS) employ multiple mechanisms to shape the vascular tree to meet its specific metabolic demands, such as promoting nerve-artery alignment in the PNS or the development the blood brain barrier in the CNS. In this article we discuss how the nervous system directly influences blood vessel patterning resulting in neuro-vascular congruence that is maintained throughout development and in the adult. PMID:21978864

  19. Effects of microbeam radiation therapy on normal and tumoral blood vessels.

    PubMed

    Bouchet, Audrey; Serduc, Raphäel; Laissue, Jean Albert; Djonov, Valentin

    2015-09-01

    Microbeam radiation therapy (MRT) is a new form of preclinical radiotherapy using quasi-parallel arrays of synchrotron X-ray microbeams. While the deposition of several hundred Grays in the microbeam paths, the normal brain tissues presents a high tolerance which is accompanied by the permanence of apparently normal vessels. Conversely, the efficiency of MRT on tumor growth control is thought to be related to a preferential damaging of tumor blood vessels. The high resistance of the healthy vascular network was demonstrated in different animal models by in vivo biphoton microscopy, magnetic resonance imaging, and histological studies. While a transient increase in permeability was shown, the structure of the vessels remained intact. The use of a chick chorioallantoic membrane at different stages of development showed that the damages induced by microbeams depend on vessel maturation. In vivo and ultrastructural observations showed negligible effects of microbeams on the mature vasculature at late stages of development; nevertheless a complete destruction of the immature capillary plexus was found in the microbeam paths. The use of MRT in rodent models revealed a preferential effect on tumor vessels. Although no major modification was observed in the vasculature of normal brain tissue, tumors showed a denudation of capillaries accompanied by transient increased permeability followed by reduced tumor perfusion and finally, a decrease in number of tumor vessels. Thus, MRT is a very promising treatment strategy with pronounced tumor control effects most likely based on the anti-vascular effects of MRT. Copyright © 2015. Published by Elsevier Ltd.

  20. Supervised retinal vessel segmentation from color fundus images based on matched filtering and AdaBoost classifier.

    PubMed

    Memari, Nogol; Ramli, Abd Rahman; Bin Saripan, M Iqbal; Mashohor, Syamsiah; Moghbel, Mehrdad

    2017-01-01

    The structure and appearance of the blood vessel network in retinal fundus images is an essential part of diagnosing various problems associated with the eyes, such as diabetes and hypertension. In this paper, an automatic retinal vessel segmentation method utilizing matched filter techniques coupled with an AdaBoost classifier is proposed. The fundus image is enhanced using morphological operations, the contrast is increased using contrast limited adaptive histogram equalization (CLAHE) method and the inhomogeneity is corrected using Retinex approach. Then, the blood vessels are enhanced using a combination of B-COSFIRE and Frangi matched filters. From this preprocessed image, different statistical features are computed on a pixel-wise basis and used in an AdaBoost classifier to extract the blood vessel network inside the image. Finally, the segmented images are postprocessed to remove the misclassified pixels and regions. The proposed method was validated using publicly accessible Digital Retinal Images for Vessel Extraction (DRIVE), Structured Analysis of the Retina (STARE) and Child Heart and Health Study in England (CHASE_DB1) datasets commonly used for determining the accuracy of retinal vessel segmentation methods. The accuracy of the proposed segmentation method was comparable to other state of the art methods while being very close to the manual segmentation provided by the second human observer with an average accuracy of 0.972, 0.951 and 0.948 in DRIVE, STARE and CHASE_DB1 datasets, respectively.

Top